WorldWideScience

Sample records for coating failure detection

  1. DETECTION OF COATING FAILURES IN A NEUTRONIC REACTOR

    Science.gov (United States)

    Snell, A.H.; Allison, S.K.

    1958-02-11

    This patent relates to water-cooled reactor systems and discloses a means to detect leaks in the jackets of jacketed fuel elements comprising a neutron detector located in the cooling water discharge pipe,the pipe being provided with an enlarged portion for housing the detector so that the latter is completely surrounded by the water in its passage through the pipe, said enlarged portion and detector being shielded from the reactor for the purpose of detecting only those delayed neutrons emitted in the cooling water and due to the latter picking up fission fragments from the defective fuel elements.

  2. Rate based failure detection

    Science.gov (United States)

    Johnson, Brett Emery Trabun; Gamage, Thoshitha Thanushka; Bakken, David Edward

    2018-01-02

    This disclosure describes, in part, a system management component and failure detection component for use in a power grid data network to identify anomalies within the network and systematically adjust the quality of service of data published by publishers and subscribed to by subscribers within the network. In one implementation, subscribers may identify a desired data rate, a minimum acceptable data rate, desired latency, minimum acceptable latency and a priority for each subscription. The failure detection component may identify an anomaly within the network and a source of the anomaly. Based on the identified anomaly, data rates and or data paths may be adjusted in real-time to ensure that the power grid data network does not become overloaded and/or fail.

  3. The result analysis by A-Frame technique in coating failure detection; Analise dos resultados do uso da tecnica A-Frame na localizacao de falhas no revestimento

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Fabio Amarante; Leite, Daniele C.F. [PETROBRAS, Rio de Janeiro, RJ (Brazil); Oliver, Joao Hipolito L. [TRANSPETRO - PETROBRAS Transportes, Rio de Janeiro, RJ (Brazil)

    2005-07-01

    This paper presents the method used to helps the on land pipeline integrity management, focusing on external corrosion control. The method is achieved by gathering together the data from an Over The Line Survey (OLS) and an In Line Inspection (ILI). As the corrosion occurs at a coating fault in a non-effective cathodic protection (cp) area, both coating and metal loss inspection data were employed in this method. The OLS is applied to pinpoint and graduate the coating faults in underground pipeline by using the Coating Attenuation / A-Frame (ACVG - Alternate Current Voltage Gradient) technic. The ILI is applied to measure the external metal loss (corrosion) by running a smart PIG tool. In some pipelines a huge number of coating fault can be found, but it doesn't mean that all of them must be repaired, so it is a need to identify the critical coating fault, so that the number of digging for coating repair can be drastically reduced. In the other way, as the smart PIG can provide data of corrosion in the pipe, the coating fault on a corroded area can be considered as a critical one. Together, those data may point the spot where the cathodic protection was not effective and the coating failure resulted in corrosion on the pipe. This method has been a helpful criterion to identify critical coating faults and reduce the overall repair cost, it can be also used to indirect evaluate the performance of cp system, since no corrosion indication on a coating fault area can be assumed that the CP is effective. (author)

  4. Fuel failure detection device

    International Nuclear Information System (INIS)

    Katagiri, Masaki.

    1979-01-01

    Purpose: To improve the SN ratio in the detection. Constitution: Improved precipitator method is provided. Scintillation detectors of a same function are provided respectively by each one before and after a gas reservoir for depositing fission products in the cover gas to detecting wires. The outputs from the two detectors (output from the wire not deposited with the fission products and the output from the wire after deposition) are compared to eliminate background noises resulted from not-decayed nucleides. A subtraction circuit is provided for the elimination. Since the background noises of the detecting wire can thus be measured and corrected on every detection, the SN ratio can be increased. (Ikeda, J.)

  5. Scratch induced failure of plasma sprayed alumina based coatings

    International Nuclear Information System (INIS)

    Hazra, S; Bandyopadhyay, P.P.

    2012-01-01

    Highlights: ► Scratch induced failure of alumina based coatings including nanostructured is reported. ► Ceramic is deposited on bond coat instead of steel, emulating a realistic situation. ► Lateral force data is supplemented with microscopy to observe coating failure. ► The failure mechanism during scratching has been identified. ► Critical load of failure has been calculated for each bond-top coat combination. -- Abstract: A set of plasma sprayed coatings were obtained from three alumina based top coat and two bond coat powders. Scratch test was undertaken on these coatings, under constant and linearly varying load. Test results include the lateral force data and scanning electron microscope (SEM) images. Failure occurred by large area spallation of the top coat and in most cases tensile cracks appeared on the exposed bond coat. The lateral force showed an increasing trend with an increase in normal load up to a certain point and beyond this, it assumed a steady average value. The locations of coating spallation and occurrence of maximum lateral force did not coincide. A bond coat did not show a significant role in determining the scratch adhesion strength.

  6. Detecting failure of climate predictions

    Science.gov (United States)

    Runge, Michael C.; Stroeve, Julienne C.; Barrett, Andrew P.; McDonald-Madden, Eve

    2016-01-01

    The practical consequences of climate change challenge society to formulate responses that are more suited to achieving long-term objectives, even if those responses have to be made in the face of uncertainty1, 2. Such a decision-analytic focus uses the products of climate science as probabilistic predictions about the effects of management policies3. Here we present methods to detect when climate predictions are failing to capture the system dynamics. For a single model, we measure goodness of fit based on the empirical distribution function, and define failure when the distribution of observed values significantly diverges from the modelled distribution. For a set of models, the same statistic can be used to provide relative weights for the individual models, and we define failure when there is no linear weighting of the ensemble models that produces a satisfactory match to the observations. Early detection of failure of a set of predictions is important for improving model predictions and the decisions based on them. We show that these methods would have detected a range shift in northern pintail 20 years before it was actually discovered, and are increasingly giving more weight to those climate models that forecast a September ice-free Arctic by 2055.

  7. Signal analysis for failure detection

    International Nuclear Information System (INIS)

    Parpaglione, M.C.; Perez, L.V.; Rubio, D.A.; Czibener, D.; D'Attellis, C.E.; Brudny, P.I.; Ruzzante, J.E.

    1994-01-01

    Several methods for analysis of acoustic emission signals are presented. They are mainly oriented to detection of changes in noisy signals and characterization of higher amplitude discrete pulses or bursts. The aim was to relate changes and events with failure, crack or wear in materials, being the final goal to obtain automatic means of detecting such changes and/or events. Performance evaluation was made using both simulated and laboratory test signals. The methods being presented are the following: 1. Application of the Hopfield Neural Network (NN) model for classifying faults in pipes and detecting wear of a bearing. 2. Application of the Kohonnen and Back Propagation Neural Network model for the same problem. 3. Application of Kalman filtering to determine time occurrence of bursts. 4. Application of a bank of Kalman filters (KF) for failure detection in pipes. 5. Study of amplitude distribution of signals for detecting changes in their shape. 6. Application of the entropy distance to measure differences between signals. (author). 10 refs, 11 figs

  8. Failure mechanism for thermal fatigue of thermal barrier coating systems

    Energy Technology Data Exchange (ETDEWEB)

    Giolli, C.; Scrivani, A.; Rizzi, G. [Turbocoating S.p.A., Rubbiano di Solignano (Italy); Borgioli, F. [Firenze Univ., Sesto Fiorentino (Italy); Bolelli, G.; Lusvarghi, L. [Univ. di Modena e Reggio Emilia, Modena (Italy)

    2008-07-01

    High temperature thermal fatigue causes the failure of Thermal Barrier Coating (TBC) systems. Due to the difference in thickness and microstructure between thick TBCs and traditional thin TBCs, they cannot be assumed a-priori to possess the same failure mechanisms. Thick TBCs, consisting of a CoNiCrAlY bond coat and Yttria Partially Stabilised Zirconia top coat with different values of porosity, were produced by Air Plasma Spray. Thermal fatigue resistance limit of TBCs was tested by Furnace Cycling Tests (FCT) according to the specifications of an Original Equipment Manufacturer (OEM). TBC systems were analyzed before and after FCT. The morphological and chemical evolution of CoNiCrAlY/TGO microstructure was studied. Sintering effect, residual stress, phase transformation and fracture toughness were evaluated in the ceramic Top Coat. All the tested samples passed FCT according to the specification of an important OEM. Thermal fatigue resistance increases with the amount of porosity in the top coat. The compressive in-plane stresses increase in the TBC systems after thermal cycling, nevertheless the increasing rate has a trend contrary to the porosity level of top coat. The data suggest that the spallation happens at the TGO/Top Coat interface. The failure mechanism of thick TBCs subjected to thermal fatigue was eventually found to be similar to the failure mechanism of thin TBC systems made by APS. (orig.)

  9. Degradation and failure characteristics of NPP containment protective coating systems

    Energy Technology Data Exchange (ETDEWEB)

    Sindelar, R.L.

    2000-03-30

    A research program to investigate the performance and potential for failure of Service Level 1 coating systems used in nuclear power plant containment is in progress. The research activities are aligned to address phenomena important to cause failure as identified by the industry coatings expert panel. The period of interest for performance covers the time from application of the coating through 40 years of service, followed by a medium-to-large break loss-of-coolant accident scenario, which is a design basis accident (DBA) scenario. The interactive program elements are discussed in this report and the application of these elements to the System 5 coating system (polyamide epoxy primer, carbon steel substrate) is used to evaluate performance.

  10. Degradation and failure characteristics of NPP containment protective coating systems

    International Nuclear Information System (INIS)

    Sindelar, R.L.

    2000-01-01

    A research program to investigate the performance and potential for failure of Service Level 1 coating systems used in nuclear power plant containment is in progress. The research activities are aligned to address phenomena important to cause failure as identified by the industry coatings expert panel. The period of interest for performance covers the time from application of the coating through 40 years of service, followed by a medium-to-large break loss-of-coolant accident scenario, which is a design basis accident (DBA) scenario. The interactive program elements are discussed in this report and the application of these elements to the System 5 coating system (polyamide epoxy primer, carbon steel substrate) is used to evaluate performance

  11. The failure mechanisms of HTR coated particle fuel and computer code

    International Nuclear Information System (INIS)

    Yang Lin; Liu Bing; Shao Youlin; Liang Tongxiang; Tang Chunhe

    2010-01-01

    The basic constituent unit of fuel element in HTR is ceramic coated particle fuel. And the performance of coated particle fuel determines the safety of HTR. In addition to the traditional detection of radiation experiments, establishing computer code is of great significance to the research. This paper mainly introduces the structure and the failure mechanism of TRISO-coated particle fuel, as well as a few basic assumptions,principles and characteristics of some existed main overseas codes. Meanwhile, this paper has proposed direction of future research by comparing the advantages and disadvantages of several computer codes. (authors)

  12. Two Contrasting Failure Modes of Enteric Coated Beads.

    Science.gov (United States)

    Shi, Galen H; Dong, Xia; Lytle, Michelle; Kemp, Craig A J; Behme, Robert J; Hinds, Jeremy; Xiao, Zhicheng

    2018-04-09

    This study aimed to elucidate the mechanisms and kinetics of coating failure for enteric coated beads exposed to high-humidity conditions at different storage temperatures. Enteric coated beads were placed on high-humidity conditions (75 to 98% relative humidity (RH)) in the temperature range of 5 to 40°C. These stability samples of beads were tested for acid dissolution and water activity and also analyzed with SEM, X-ray CT, and DMA. Exposure of enteric coated beads to high humidity led to increased gastric release of drug which eventually failed the dissolution specification. SEM showed visible cracks on the surface of beads exposed to 5°C/high humidity and fusion of enteric beads into agglomerates at 40°C/high humidity. In a non-destructive time elapse study, X-ray CT demonstrated swelling of microcrystalline cellulose cores, crack initiation, and propagation through the API layer within days under 5°C/98% RH storage conditions and ultimately fracture through the enteric coating. DMA data showed a marked reduction in T g of the enteric coating materials after exposure to humidity. At 5°C/high humidity, the hygroscopic microcrystalline cellulose core absorbed moisture leading to core swelling and consequent fracture through the brittle API and enteric layers. At 40°C (high humidity) which is above the T g of the enteric polymer, enteric coated beads coalesced into agglomerates due to melt flow of the enteric coating. We believe it is the first report on two distinct failure models of enteric coated dosage forms.

  13. Improved GLR method to instrument failure detection

    International Nuclear Information System (INIS)

    Jeong, Hak Yeoung; Chang, Soon Heung

    1985-01-01

    The generalized likehood radio(GLR) method performs statistical tests on the innovations sequence of a Kalman-Buchy filter state estimator for system failure detection and its identification. However, the major drawback of the convensional GLR is to hypothesize particular failure type in each case. In this paper, a method to solve this drawback is proposed. The improved GLR method is applied to a PWR pressurizer and gives successful results in detection and identification of any failure. Furthmore, some benefit on the processing time per each cycle of failure detection and its identification can be accompanied. (Author)

  14. A failure detection and isolation system simulator

    International Nuclear Information System (INIS)

    Assumpcao Filho, E.O.; Nakata, H.

    1990-04-01

    A failure detection and isolation system (FDI) simulation program has been developed for IBM-PC microcomputers. The program, based on the sequential likelihood ratio testing method developed by A. Wald, was implemented with the Monte-Carlo technique. The calculated failure detection rate was favorably compared against the wind-tunnel experimental redundant temperature sensors. (author) [pt

  15. Physicochemical characterization and failure analysis of military coating systems

    Science.gov (United States)

    Keene, Lionel Thomas

    Modern military coating systems, as fielded by all branches of the U.S. military, generally consist of a diverse array of organic and inorganic components that can complicate their physicochemical analysis. These coating systems consist of VOC-solvent/waterborne automotive grade polyurethane matrix containing a variety of inorganic pigments and flattening agents. The research presented here was designed to overcome the practical difficulties regarding the study of such systems through the combined application of several cross-disciplinary techniques, including vibrational spectroscopy, electron microscopy, microtomy, ultra-fast laser ablation and optical interferometry. The goal of this research has been to determine the degree and spatial progression of weathering-induced alteration of military coating systems as a whole, as well as to determine the failure modes involved, and characterizing the impact of these failures on the physical barrier performance of the coatings. Transmission-mode Fourier Transform Infrared (FTIR) spectroscopy has been applied to cross-sections of both baseline and artificially weathered samples to elucidate weathering-induced spatial gradients to the baseline chemistry of the coatings. A large discrepancy in physical durability (as indicated by the spatial progression of these gradients) has been found between older and newer generation coatings. Data will be shown implicating silica fillers (previously considered inert) as the probable cause for this behavioral divergence. A case study is presented wherein the application of the aforementioned FTIR technique fails to predict the durability of the coating system as a whole. The exploitation of the ultra-fast optical phenomenon of femtosecond (10-15S) laser ablation is studied as a potential tool to facilitate spectroscopic depth profiling of composite materials. Finally, the interferometric technique of Phase Shifting was evaluated as a potential high-sensitivity technique applied to the

  16. Detecting virological failure in HIVinfected Tanzanian children ...

    African Journals Online (AJOL)

    Background. The performance of clinical and immunological criteria to predict virological failure in HIV-infected children receiving antiretroviral therapy (ART) is not well documented. Objective. To determine the validity of clinical and immunological monitoring in detecting virological failure in children on ART. Methods.

  17. New Method to Identify Field Joint Coating Failures Based on MFL In-Line Inspection Signals

    Directory of Open Access Journals (Sweden)

    Lianshuang Dai

    2018-02-01

    Full Text Available Above ground indirect detections and random excavations that have applied the past years for buried long distance oil and gas pipelines can only identify some damaged coating locations. Hence, large number of field joint coating (FJC failures happen unconsciously until they lead to failures of the pipelines. Based on the analysis of magnetic flux leakage (MFL in-line inspection (ILI signals, combined with the statistical results of 414 excavations from two different pipeline sections, a new method to identify the failed FJC is established. Though it can only identify FJC failures when there are signs of corrosion on pipe body, it is much more efficient and cost-saving. The concluded identification rule still needs more validations and improvements to be more applicable and accuracy.

  18. Failure Prediction And Detection In Cloud Datacenters

    Directory of Open Access Journals (Sweden)

    Purvil Bambharolia

    2017-09-01

    Full Text Available Cloud computing is a novel technology in the field of distributed computing. Usage of Cloud computing is increasing rapidly day by day. In order to serve the customers and businesses satisfactorily fault occurring in datacenters and servers must be detected and predicted efficiently in order to launch mechanisms to tolerate the failures occurred. Failure in one of the hosted datacenters may propagate to other datacenters and make the situation worse. In order to prevent such situations one can predict a failure proliferating throughout the cloud computing system and launch mechanisms to deal with it proactively. One of the ways to predict failures is to train a machine to predict failure on the basis of messages or logs passed between various components of the cloud. In the training session the machine can identify certain message patterns relating to failure of data centers. Later on the machine can be used to check whether a certain group of message logs follow such patterns or not. Moreover each cloud server can be defined by a state which indicates whether the cloud is running properly or is facing some failure. Parameters such as CPU usage memory usage etc. can be maintained for each of the servers. Using this parameters we can add a layer of detection where in we develop a decision tree based on these parameters which can classify whether the passed in parameters to the decision tree indicate failure state or proper state.

  19. Some calculations of the failure statistics of coated fuel particles

    International Nuclear Information System (INIS)

    Martin, D.G.; Hobbs, J.E.

    1977-03-01

    Statistical variations of coated fuel particle parameters were considered in stress model calculations and the resulting particle failure fraction versus burn-up evaluated. Variations in the following parameters were considered simultaneously: kernel diameter and porosity, thickness of the buffer, seal, silicon carbide and inner and outer pyrocarbon layers, which were all assumed to be normally distributed, and the silicon carbide fracture stress which was assumed to follow a Weibull distribution. Two methods, based respectively on random sampling and convolution of the variations were employed and applied to particles manufactured by Dragon Project and RFL Springfields. Convolution calculations proved the more satisfactory. In the present calculations variations in the silicon carbide fracture stress caused the greatest spread in burn-up for a given change in failure fraction; kernel porosity is the next most important parameter. (author)

  20. Failure of the capsule for coated particles irradiation

    International Nuclear Information System (INIS)

    Yamaki, Jikei; Nomura, Yasushi; Nagamatsuya, Takaaki; Yamahara, Takeshi; Sakai, Haruyuki

    1975-10-01

    During operation cycle No. 27 of the JMTR (Japan Material Testing Reactor) on May 20, 1974, leakage of the fission product gas occurred from the capsule 72F-7A, which contained coated particles for the irradiation; the coated particles are for the development of a multi-purpose high temperature gas cooled reactor. The capsule was designed for heat 1600 0 C. Three nickel plates as the heat reflector were sandwiched in between the plates of titanium and zirconium, which were adsorbents for the impurity gases in the cladding tube (Nb-1%Zr). Temperatures of the plates were about 1000 0 C under the irradiation, so one metal diffused into the other metal through interfaces, resulting in the formation of an alloy. Its melting point was lower than those of metals in the capsule. The cladding material Nb-1%Zr was melted by the alloy and finally a pin hole developed through the cladding. The process of failure, design of the capsule, post-irradiation test of the capsule and the failure-reproducing experiment with a mock-up capsule are described. (auth.)

  1. Fuel failure detection in operating reactors

    International Nuclear Information System (INIS)

    Seigel, B.; Hagen, H.H.

    1977-12-01

    Activity detectors in commercial BWRs and PWRs are examined to determine their capability to detect a small number of fuel rod failures during reactor operation. The off-gas system radiation monitor in a BWR and the letdown line radiation monitor in a PWR are calculated to have this capability, and events are cited that support this analysis. Other common detectors are found to be insensitive to small numbers of fuel failures. While adequate detectors exist for normal and transient operation, those detectors would not perform rapidly enough to be useful during accidents; in most accidents, however, primary system sensors (pressure, temperature, level) would provide adequate warning. Advanced methods of fuel failure detection are mentioned

  2. Knowledge representation methods for early failure detection

    International Nuclear Information System (INIS)

    Scherer, K.P.; Stiller, P.

    1990-01-01

    To supervise technical processes like nuclear power plants, it is very important to detect failure modes in an early stage. In the nuclear research center at Karlsruhe an expert system is developed, embedded in a computer network of autonomous computers, which are used for intelligent prepocessing. Events, process data and actual parameter values are stored in slots of special frames in the knowledge base of the expert system. Both rule based and fact based knowledge representations are employed to generate cause consequence chains of failure states. By on-line surveillance of the reactor process, the slots of the frames are dynamically actualized. Immediately after the evaluation, the inference engine starts in the special domain experts (triggered by metarules from a manager) and detects the correspondend failures or anomaly state. Matching the members of the chain and regarding a catalogue of instructions and messages, what is to do by the operator, future failure states can be estimated and propagation can be prohibited. That means qualitative failure prediction based on cause consequence in the static part of the knowledge base. Also, a time series of physical data can be used to predict on analytical way future process state and to continue such a theoretical propagation with matching the cause consuquence chain

  3. Device for detecting failure of reactor system

    International Nuclear Information System (INIS)

    Miyazawa, Tatsuo.

    1979-01-01

    Purpose: To make it possible to rapidly detect any failure in a reactor system prior to the leakage of coolants. Constitution: The dose of beta line is computed from the difference between the power of a detector for reacting with both beta and gamma lines and a detector for reacting only with gamma line to detect the failure of a reactor system, thereby to raise the detection speed and improve the detection accuracy. More specifically, a radiation detector A detects gamma and beta lines by means of piezoelectric elements. A radiation detector B caused the opening of the detector A to be covered with a metal, and detects only gamma line. The detected values of detectors A and B are amplified by an amplifier and applied to a rate meter and a counter, the values being converted into DC and introduced into a comparison circuit, where the outputs of the rate meter are compared with each other. When the difference is more than the predetermined range, it is supplied as output to an alarm circuit where an alarm signal is produced. (Nakamura, S.)

  4. Failure detection studies by layered neural network

    International Nuclear Information System (INIS)

    Ciftcioglu, O.; Seker, S.; Turkcan, E.

    1991-06-01

    Failure detection studies by layered neural network (NN) are described. The particular application area is an operating nuclear power plant and the failure detection is of concern as result of system surveillance in real-time. The NN system is considered to be consisting of 3 layers, one of which being hidden, and the NN parameters are determined adaptively by the backpropagation (BP) method, the process being the training phase. Studies are performed using the power spectra of the pressure signal of the primary system of an operating nuclear power plant of PWR type. The studies revealed that, by means of NN approach, failure detection can effectively be carried out using the redundant information as well as this is the case in this work; namely, from measurement of the primary pressure signals one can estimate the primary system coolant temperature and hence the deviation from the operational temperature state, the operational status identified in the training phase being referred to as normal. (author). 13 refs.; 4 figs.; 2 tabs

  5. Failure detection system risk reduction assessment

    Science.gov (United States)

    Aguilar, Robert B. (Inventor); Huang, Zhaofeng (Inventor)

    2012-01-01

    A process includes determining a probability of a failure mode of a system being analyzed reaching a failure limit as a function of time to failure limit, determining a probability of a mitigation of the failure mode as a function of a time to failure limit, and quantifying a risk reduction based on the probability of the failure mode reaching the failure limit and the probability of the mitigation.

  6. FAILURE MECHANISMS OF THERMAL BARRIER COATINGS INTERNAL COMBUSTION ENGINES AND llMPROVEMENTS

    Directory of Open Access Journals (Sweden)

    ADNAN PARLAK

    2003-04-01

    Full Text Available MechanicaJ properties of high performance ceramics have been improved to the point where their use in heat engines is possible. The high temperature strength and low thermal expansion properties of bigh performance ceramics offer an advantage over metals in the development of non-water cooling engine. However, because bard environment in diesel engine combustion chamber, solving the problem of durabiUty of TBC is important. DurabiUty of thermal barrier coatings(TBC is liınited by two main failure mechanisms: Therınal expansion nlİsmatch betwcen bond coat and top coat and bond coat oxidation. Both of these can cause failure of the ceramic top coat. Developments of recent years sholv that bond coats \\Vith higher oxidation resistance tend to have better coating system cyclic lives

  7. Failure behavior of nano-SiO2 fillers epoxy coating under hydrostatic pressure

    International Nuclear Information System (INIS)

    Liu Li; Cui Yu; Li Ying; Zhang Tao; Wang Fuhui

    2012-01-01

    The failure of organic coating (epoxy resin filled with 5 mass% nano-SiO 2 particles) on mild steel under high hydrostatic pressure (35 atm) has been studied compared with that under atmospheric pressure (1 atm), using impedance measurements, gravimetric testing, adhesion testing and scanning electron microscopy (SEM). The results show that high hydrostatic pressure accelerated the failure of the organic coating by promoting diffusion of water in the coating, which speeds up water spread and electrochemical reactions at the interface. The roughness of the coating and steel has been discussed from point of view of their respective fractal dimensions D fc and D fdl , as deduced from impedance measurements

  8. Thermal failure of nanostructured thermal barrier coatings with cold sprayed nanostructured NiCrAlY bond coat

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Q.; Li, Y.; Zhang, S.L.; Wang, X.R.; Yang, G.J.; Li, C.X.; Li, C.J. [Xi' an Jiaotong Univ., Xi' an (China)

    2008-07-01

    Nanostructured YSZ is expected to exhibit a high strain tolerability due to its low Young's modulus and consequently high durability. In this study, a porous YSZ as the thermal barrier coating was deposited by plasma spraying using an agglomerated nanostructured YSZ powder on a Ni-based superalloy Inconel 738 substrate with a cold-sprayed nanostructured NiCrAlY as the bond coat. The heat treatment in Ar atmosphere was applied to the cold-sprayed bond coat before deposition of YSZ. The isothermal oxidation and thermal cycling tests were applied to examine failure modes of plasma-sprayed nanostructured YSZ. The results showed that YSZ coating was deposited by partially melted YSZ particles. The nonmelted fraction of spray particles retains the porous nanostructure of the starting powder into the deposit. YSZ coating exhibits a bimodal microstructure consisting of nanosized particles retained from the powder and micro-columnar grains formed through the solidification of the melted fraction in spray particles. The oxidation of the bond coat occurs during the heat treatment in Ar atmosphere. The uniform oxide at the interface between the bond coat and YSZ can be formed during isothermal test. The cracks were observed at the interface between TGO/BC or TGO/YSZ after thermal cyclic test. However, the failure of TBCs mainly occurred through spalling of YSZ within YSZ coating. The failure characteristics of plasma-sprayed nanostructured YSZ are discussed based on the coating microstructure and formation of TGO on the bond coat surface. (orig.)

  9. Method of detecting a fuel element failure

    International Nuclear Information System (INIS)

    Cohen, P.

    1975-01-01

    A method is described for detecting a fuel element failure in a liquid-sodium-cooled fast breeder reactor consisting of equilibrating a sample of the coolant with a molten salt consisting of a mixture of barium iodide and strontium iodide (or other iodides) whereby a large fraction of any radioactive iodine present in the liquid sodium coolant exchanges with the iodine present in the salt; separating the molten salt and sodium; if necessary, equilibrating the molten salt with nonradioactive sodium and separating the molten salt and sodium; and monitoring the molten salt for the presence of iodine, the presence of iodine indicating that the cladding of a fuel element has failed. (U.S.)

  10. Link failure detection in a parallel computer

    Science.gov (United States)

    Archer, Charles J.; Blocksome, Michael A.; Megerian, Mark G.; Smith, Brian E.

    2010-11-09

    Methods, apparatus, and products are disclosed for link failure detection in a parallel computer including compute nodes connected in a rectangular mesh network, each pair of adjacent compute nodes in the rectangular mesh network connected together using a pair of links, that includes: assigning each compute node to either a first group or a second group such that adjacent compute nodes in the rectangular mesh network are assigned to different groups; sending, by each of the compute nodes assigned to the first group, a first test message to each adjacent compute node assigned to the second group; determining, by each of the compute nodes assigned to the second group, whether the first test message was received from each adjacent compute node assigned to the first group; and notifying a user, by each of the compute nodes assigned to the second group, whether the first test message was received.

  11. Understanding cracking failures of coatings: A fracture mechanics approach

    Science.gov (United States)

    Kim, Sung-Ryong

    A fracture mechanics analysis of coating (paint) cracking was developed. A strain energy release rate (G(sub c)) expression due to the formation of a new crack in a coating was derived for bending and tension loadings in terms of the moduli, thicknesses, Poisson's ratios, load, residual strain, etc. Four-point bending and instrumented impact tests were used to determine the in-situ fracture toughness of coatings as functions of increasing baking (drying) time. The system used was a thin coating layer on a thick substrate layer. The substrates included steel, aluminum, polycarbonate, acrylonitrile-butadiene-styrene (ABS), and Noryl. The coatings included newly developed automotive paints. The four-point bending configuration promoted nice transversed multiple coating cracks on both steel and polymeric substrates. The crosslinked type automotive coatings on steel substrates showed big cracks without microcracks. When theoretical predictions for energy release rate were compared to experimental data for coating/steel substrate samples with multiple cracking, the agreement was good. Crosslinked type coatings on polymeric substrates showed more cracks than theory predicted and the G(sub c)'s were high. Solvent evaporation type coatings on polymeric substrates showed clean multiple cracking and the G(sub c)'s were higher than those obtained by tension analysis of tension experiments with the same substrates. All the polymeric samples showed surface embrittlement after long baking times using four-point bending tests. The most apparent surface embrittlement was observed in the acrylonitrile-butadiene-styrene (ABS) substrate system. The impact properties of coatings as a function of baking time were also investigated. These experiments were performed using an instrumented impact tester. There was a rapid decrease in G(sub c) at short baking times and convergence to a constant value at long baking times. The surface embrittlement conditions and an embrittlement toughness

  12. Fuel failure detection and location in LMFBRs

    International Nuclear Information System (INIS)

    Jacobi, S.

    1982-06-01

    The Specialists' Meeting on 'Fuel Failure Detection and Location in LMFBRs' was held at the Kernforschungszentrum Karlsruhe, Federal Republic of Germany, on 11-14 May 1981. The meeting was sponsored by the International Atomic Energy Agency (IAEA) on the recommendation of the International Working Group on Fast Reactors (IWGFR).The purpose of the meeting was to review and discuss methods and experience in the detection and location of failed fuel elements and to recommend future development. The technical sessions were divided into five topical sessions as follows: 1. Reactor Intrumentation, 2. Experience Gained from LMFBRs, 3. In-pile Experiments, 4. Models and Codes, 5. Future Programs. During the meeting papers were presented by the participants on behalf of their countries or organizations. Each presentation was followed by an open discussion in the subject covered by the presentation. After the formal sessions were completed, a final discussion session was held and general conclusions and recommendationswere reached. Session summaries, general conclusions and recommendations, the agenda of the meeting and the list of participants are given. (orig./RW)

  13. Automatic patient respiration failure detection system with wireless transmission

    Science.gov (United States)

    Dimeff, J.; Pope, J. M.

    1968-01-01

    Automatic respiration failure detection system detects respiration failure in patients with a surgically implanted tracheostomy tube, and actuates an audible and/or visual alarm. The system incorporates a miniature radio transmitter so that the patient is unencumbered by wires yet can be monitored from a remote location.

  14. Artificial-neural-network-based failure detection and isolation

    Science.gov (United States)

    Sadok, Mokhtar; Gharsalli, Imed; Alouani, Ali T.

    1998-03-01

    This paper presents the design of a systematic failure detection and isolation system that uses the concept of failure sensitive variables (FSV) and artificial neural networks (ANN). The proposed approach was applied to tube leak detection in a utility boiler system. Results of the experimental testing are presented in the paper.

  15. Calculating failure probabilities for TRISO-coated fuel particles using an integral formulation

    International Nuclear Information System (INIS)

    Miller, Gregory K.; Maki, John T.; Knudson, Darrell L.; Petti, David A.

    2010-01-01

    The fundamental design for a gas-cooled reactor relies on the safe behavior of the coated particle fuel. The coating layers surrounding the fuel kernels in these spherical particles, termed the TRISO coating, act as a pressure vessel that retains fission products. The quality of the fuel is reflected in the number of particle failures that occur during reactor operation, where failed particles become a source for fission products that can then diffuse through the fuel element. The failure probability for any batch of particles, which has traditionally been calculated using the Monte Carlo method, depends on statistical variations in design parameters and on variations in the strengths of coating layers among particles in the batch. An alternative approach to calculating failure probabilities is developed herein that uses direct numerical integration of a failure probability integral. Because this is a multiple integral where the statistically varying parameters become integration variables, a fast numerical integration approach is also developed. In sample cases analyzed involving multiple failure mechanisms, results from the integration methods agree closely with Monte Carlo results. Additionally, the fast integration approach, particularly, is shown to significantly improve efficiency of failure probability calculations. These integration methods have been implemented in the PARFUME fuel performance code along with the Monte Carlo method, where each serves to verify accuracy of the others.

  16. Fuel failure detection and location methods in CAGRs

    International Nuclear Information System (INIS)

    Harris, A.M.

    1982-06-01

    The release of fission products from AGR fuel failures and the way in which the signals from such failures must be detected against the background signal from uranium contamination of the fuel is considered. Theoretical assessments of failure detection are used to show the limitations of the existing Electrostatic Wire Precipitator Burst Can Detection system (BCD) and how its operating parameters can be optimised. Two promising alternative methods, the 'split count' technique and the use of iodine measurements, are described. The results of a detailed study of the mechanical and electronic performance of the present BCD trolleys are given. The limited experience of detection and location of two fuel failures in CAGR using conventional and alternative methods is reviewed. The larger failure was detected and located using the conventional BCD equipment with a high confidence level. It is shown that smaller failures may not be easy to detect and locate using the current BCD equipment, and the second smaller failure probably remained in the reactor for about a year before it was discharged. The split count technique used with modified BCD equipment was able to detect the smaller failure after careful inspection of the data. (author)

  17. Failure modes observed on worn surfaces of W-C-Co sputtered coatings

    International Nuclear Information System (INIS)

    Ramalho, A.; Cavaleiro, A.; Miranda, A.S.; Vieira, M.T.

    1993-01-01

    During scratch testing, the indenter gives rise to a distribution of stresses similar to that observed in tribocontacts. In this work, r.f.-sputtered W-C-Co coatings deposited from sintered WC + Co (6, 10 and 15 wt.% Co) at various substrate biases were scratched and tested tribologically and the morphology of the damaged surfaces was analysed. The cobalt content of the coatings is the main factor determining their tribological characteristics. The failure modes observed on the worn pin-on-disc tested surfaces are explained and compared with those obtained by scratch testing. In spite of it not being possible to establish quantitative results for the wear resistance of W-C-Co coatings from scratch testing, an estimation can be performed based on the observation of the failure modes in the scratch track. Thus scratch testing can be used to predict the tribological behaviour of coated surfaces. This possibility can reduce the number and cost of tribological tests. (orig.)

  18. Failure mechanism of coated biomaterials under high impact-sliding contact stresses

    Science.gov (United States)

    Chen, Ying

    This study uses a newly developed testing method--- inclined cyclic impact-sliding test to investigate the failure behaviors of different types of biomaterials, (SS316L, Ti6Al4V and CoCr) coated by different coatings (TiN, DLC and PEO), under extremely high dynamic contact stress conditions. This test method can simulate the combined impact and sliding/rolling loading conditions, which is very practical in many aspects of commercial usages. During the tests, fatigue cracking, chipping, peeling and material transferring were observed in damaged area. This research is mainly focused on the failure behaviors of load-bearing materials which cyclic impacting and sliding are always involved. This purpose was accomplished in the three stages: First, impact-sliding test was carried out on TiN coated unhardened M2. It was found that soft substrate can cause early failure of coating due to the considerable plastic deformation in the substrate. In this case, stronger substrate is required to support coating better when tested under high contact stresses. Second, PEO coated Ti-6Al-4V was tested under pure sliding and impact-sliding wear conditions. PEO coating was found not strong enough to afford the high contact pressure under cyclic impact-sliding wear test due to its porous surface structure. However, the wear performance of PEO coating was enhanced due to the sub-stoichiometric oxide. To sum up, for load-bearing biomedical implants involved in high impacting movement, PEO coating may not be a promising surface protection. Third, the dense, smooth PVD/CVD bio-inert coatings were reconsidered. DLC and TiN coatings, combined by different substrates together with different interface materials were tested under the cyclic impact-sliding test using a set of proper loading. The results show that to choose a proper combination of coating, interface and substrate based on their mechanical properties is of great importance under the test condition. Hard substrates provide support

  19. Characterization of the failure behavior of zinc coating on dual phase steel under tensile deformation

    International Nuclear Information System (INIS)

    Song Guiming; Sloof, Willem G.

    2011-01-01

    Highlights: → The microcracks and voids at the zinc grain boundaries are the initial sites for the coating cracking. → The crack spacing of the fragmentally fractured zinc coating is mainly determined by the zinc grain size. → Small zinc grain size and the c-axis direction of zinc grain parallel to the zinc surface are beneficial to the mitigation of the zinc coating delamination. - Abstract: The failure behavior of hot-dip galvanized zinc coatings on dual phase steels under tensile deformation is characterized with in situ scanning electron microscopy (SEM). Under tension, the pre-existed microcracks and voids at the zinc grain boundaries propagate along the zinc grain boundaries to form crack nets within the coating, leading to a segmented fracture of the zinc coating with the crack spacing approximately equal to the zinc grain size. With further loading, the coating segments partially delaminated along the interface between the top zinc layer and the inhibition layer instead of the interface between the inhibition layer and steel substrate. As the c-axis of zinc grains trends to be normal to the tensile loading direction, the twinning deformation became more noticeable, and meanwhile the coating delamination was diminished. The transverse and incline tunneling cracks occurred in the inhibition layer with tensile deformation. The existence of the brittle FeZn 13 particles on top of the inhibition layer was unfavorable to the coating adhesion.

  20. Thermo-mechanical Fatigue Failure of Thermal Barrier Coated Superalloy Specimen

    Science.gov (United States)

    Subramanian, Rajivgandhi; Mori, Yuzuru; Yamagishi, Satoshi; Okazaki, Masakazu

    2015-09-01

    Failure behavior of thermal barrier coated (TBC) Ni-based superalloy specimens were studied from the aspect of the effect of bond coat material behavior on low cycle fatigue (LCF) and thermo-mechanical fatigue (TMF) at various temperatures and under various loading conditions. Initially, monotonic tensile tests were carried out on a MCrAlY alloy bond coat material in the temperature range of 298 K to 1273 K (25 °C to 1000 °C). Special attention was paid to understand the ductile to brittle transition temperature (DBTT). Next, LCF and TMF tests were carried out on the thermal barrier coated Ni-based alloy IN738 specimen. After these tests, the specimens were sectioned to understand their failure mechanisms on the basis of DBTT of the bond coat material. Experimental results demonstrated that the LCF and TMF lives of the TBC specimen were closely related to the DBTT of the bond coat material, and also the TMF lives were different from those of LCF tests. It has also been observed that the crack density in the bond coat in the TBC specimen was significantly dependent on the test conditions. More importantly, not only the number of cracks but also the crack penetration probability into substrate were shown to be sensitive to the DBTT.

  1. Failure position detection device for nuclear fuel rod

    International Nuclear Information System (INIS)

    Ishida, Takeshi; Higuchi, Shin-ichi; Ito, Masaru; Matsuda, Yasuhiko

    1987-01-01

    Purpose: To easily detect failure position of a nuclear fuel rod by relatively moving an air-tightly shielded detection portion to a fuel rod. Constitution: For detecting the failure position of a leaked fuel assembly, the fuel assembly is dismantled and a portion of withdrawn fuel rod is air-tightly sealed with an inspection portion. The inside of the inspection portion is maintained at a pressure-reduced state. Then, in a case if failed openings are formed at a portion sealed by the inspection portion in the fuel rod, FP gases in the fuel rod are released based on the reduced pressure and the FP gases are detected in the detection portion. Accordingly, by relatively moving the detection portion to the fuel rod, the failure position can be detected. (Yoshino, Y.)

  2. Failure position detection device for nuclear fuel rod

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Takeshi; Higuchi, Shin-ichi; Ito, Masaru; Matsuda, Yasuhiko

    1987-03-24

    Purpose: To easily detect failure position of a nuclear fuel rod by relatively moving an air-tightly shielded detection portion to a fuel rod. Constitution: For detecting the failure position of a leaked fuel assembly, the fuel assembly is dismantled and a portion of withdrawn fuel rod is air-tightly sealed with an inspection portion. The inside of the inspection portion is maintained at a pressure-reduced state. Then, in a case if failed openings are formed at a portion sealed by the inspection portion in the fuel rod, FP gases in the fuel rod are released based on the reduced pressure and the FP gases are detected in the detection portion. Accordingly, by relatively moving the detection portion to the fuel rod, the failure position can be detected. (Yoshino, Y.).

  3. Detection of Failure in Asynchronous Motor Using Soft Computing Method

    Science.gov (United States)

    Vinoth Kumar, K.; Sony, Kevin; Achenkunju John, Alan; Kuriakose, Anto; John, Ano P.

    2018-04-01

    This paper investigates the stator short winding failure of asynchronous motor also their effects on motor current spectrums. A fuzzy logic approach i.e., model based technique possibly will help to detect the asynchronous motor failure. Actually, fuzzy logic similar to humanoid intelligent methods besides expected linguistic empowering inferences through vague statistics. The dynamic model is technologically advanced for asynchronous motor by means of fuzzy logic classifier towards investigate the stator inter turn failure in addition open phase failure. A hardware implementation was carried out with LabVIEW for the online-monitoring of faults.

  4. Development of failure-detecting device for γ radioimmunoassay counter

    International Nuclear Information System (INIS)

    Shao Xianzhi; Zhang Bingfeng

    1997-01-01

    A failures-detecting device based on single chip microcomputer technique for detecting of failures of γ radioimmunoassay counter is developed. The device can output signals of variable amplitude and frequency similar to the pulse of γ particle for shooting problem parts of γ counter's detecting system. By automatically comparing the shapes and amplitudes of the two signals to and from an amplifier unit, the device can distinguish if the amplifier unit works normally. The differential-input amplifier circuit gives 0.1% accuracy for the measurement of the stability of high voltage. The pulse widen circuit of this device allows for middle speed A/D detecting of periodical low-frequency pulse waves of micro-second width. This device is used specifically for the maintaining and failure-detecting of γ radioimmunoassay counter

  5. Fuel rod failure detection method and system

    International Nuclear Information System (INIS)

    Assmann, H.; Janson, W.; Stehle, H.; Wahode, P.

    1975-01-01

    The inventor claims a method for the detection of a defective fuel rod cladding tube or of inleaked water in the cladding tube of a fuel rod in the fuel assembly of a pressurized-water reactor. The fuel assembly is not disassembled but examined as a whole. In the examination, the cladding tube is heated near one of its two end plugs, e.g. with an attached high-frequency inductor. The water contained in the cladding tube evaporates, and steam bubbles or a condensate are detected by the ultrasonic impulse-echo method. It is also possible to measure the delay of the temperature rise at the end plug or to determine the cooling energy required to keep the end plug temperature stable and thus to detect water ingression. (DG/AK) [de

  6. The analysis of adhesion failure between Ni-coating and sintered NdFeB substrate

    Energy Technology Data Exchange (ETDEWEB)

    Hengxiu, Y; Yong, D; Zhenlun, S, E-mail: yanghengxiu@nimte.ac.cn [Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, 315201 (China)

    2011-01-01

    Ni-coating was widely used to protect the sintered NdFeB magnet from corrosion by Watt electro-deposition solution. However, the protection failure always occurs due to poor adhesion strength between Ni-coating and NdFeB substrate. In present work, the adhesion strength of the Ni-coating on NdFeB substrate was measured by vertical tensile method to strip Ni-coating from NdFeB substrate. The results revealed that the adhesion failure was occurred in the side of the NdFeB substrate due to a weak zone sometimes shown cracks located inside of NdFeB substrate, rather than in the interface between Ni-coating and NdFeB substrate. Comparing with cross section morphology of NdFeB magnet after pretreatment, it is concluded that the crack could be formed during the electro-deposition process. The effect of the pH value of bath on adhesion strength indicated that the crack could be induced due to electrochemical hydrogenation of NdFeB substrate during electro-deposition.

  7. Failure Mechanisms of the Protective Coatings for the Hot Stamping Applications

    Science.gov (United States)

    Zhao, Chen

    In the present study, four different nitriding techniques were carried on the ductile irons NAAMS-D6510 and cast steels NAAMS-S0050A, which are widely used stamping die materials; duplex treatments (PVD CrN coating+nitriding) were carried on H13 steels, which are common inserts for the hot stamping dies. Inclined impact-sliding wear tests were performed on the nitriding cases under simulated stamping conditions. Surface profilometer, scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS) were used to investigate the wear and failure mechanisms of the protective coatings. It was found that the nitrided ductile iron samples performed better than the nitrided cast steel specimens. High temperature inclined impact-sliding wear tests were carried out on the CrN coatings. It was found that the coating performed better at elevated temperature. XPS analysis indicated the top surface layer (about 3-4nm) of the coating was oxidized at 400 °C and formed a Cr2O3 protective film. The in-situ formation of the thin Cr2O3 protective layer likely led to the change of wear mechanisms from severe adhesive failure to mild abrasive wear.

  8. Triplexer Monitor Design for Failure Detection in FTTH System

    Science.gov (United States)

    Fu, Minglei; Le, Zichun; Hu, Jinhua; Fei, Xia

    2012-09-01

    Triplexer was one of the key components in FTTH systems, which employed an analog overlay channel for video broadcasting in addition to bidirectional digital transmission. To enhance the survivability of triplexer as well as the robustness of FTTH system, a multi-ports device named triplexer monitor was designed and realized, by which failures at triplexer ports can be detected and localized. Triplexer monitor was composed of integrated circuits and its four input ports were connected with the beam splitter whose power division ratio was 95∶5. By means of detecting the sampled optical signal from the beam splitters, triplexer monitor tracked the status of the four ports in triplexer (e.g. 1310 nm, 1490 nm, 1550 nm and com ports). In this paper, the operation scenario of the triplexer monitor with external optical devices was addressed. And the integrated circuit structure of the triplexer monitor was also given. Furthermore, a failure localization algorithm was proposed, which based on the state transition diagram. In order to measure the failure detection and localization time under the circumstance of different failed ports, an experimental test-bed was built. Experiment results showed that the detection time for the failure at 1310 nm port by the triplexer monitor was less than 8.20 ms. For the failure at 1490 nm or 1550 nm port it was less than 8.20 ms and for the failure at com port it was less than 7.20 ms.

  9. Development of advanced fabrication technology for high-temperature gas-cooled reactor fuel. Reduction of coating failure fraction

    International Nuclear Information System (INIS)

    Minato, Kazuo; Kikuchi, Hironobu; Fukuda, Kousaku; Tobita, Tsutomu; Yoshimuta, Sigeharu; Suzuki, Nobuyuki; Tomimoto, Hiroshi; Nishimura, Kazuhisa; Oda, Takafumi

    1998-11-01

    The advanced fabrication technology for high-temperature gas-cooled reactor fuel has been developed to reduce the coating failure fraction of the fuel particles, which leads to an improvement of the reactor safety. The present report reviews the results of the relevant work. The mechanisms of the coating failure of the fuel particles during coating and compaction processes of the fuel fabrication were studied to determine a way to reduce the coating failure fraction of the fuel. The coating process was improved by optimizing the mode of the particle fluidization and by developing the process without unloading and loading of the particles at intermediate coating process. The compaction process was improved by optimizing the combination of the pressing temperature and the pressing speed of the overcoated particles. Through these modifications of the fabrication process, the quality of the fuel was improved outstandingly. (author)

  10. Failure Mechanism of a Stellite Coating on Heat-Resistant Steel

    Science.gov (United States)

    Wang, Dong; Zhao, Haixing; Wang, Huang; Li, Yuyan; Liu, Xia; He, Guo

    2017-09-01

    The Stellite 21 coating on the heat-resistant steel X12CrMoWVNbN10-1-1 (so-called COSTE) used in a steam turbine valve was found to be fatigue broken after service at around 873 K (600 °C) for about 8 years. In order to investigate the failure mechanism, a fresh Stellite 21 coating was also prepared on the same COSTE steel substrate by using the similar deposition parameters for comparison. It was found that the Stellite 21 coating was significantly diluted by the steel, resulting in a thin Fe-rich layer in the coating close to the fusion line. Such high Fe concentration together with the incessant Fe diffusion from the steel substrate to the coating during the service condition (about 873 K (600 °C) for long time) induced the eutectoid decomposition of the fcc α-Co(Fe,Cr,Mo) solid solution, forming an irregular eutectoid microstructure that was composed of the primitive cubic α'-FeCo(Cr,Mo) phase and the tetragonal σ-CrCo(Fe,Mo) phase. The brittle nature of such α'/ σ eutectoid microstructure contributed to the fatigue fracture of the Stellite 21 coating, resulting in an intergranular rupture mode.

  11. Sensor Failure Detection of FASSIP System using Principal Component Analysis

    Science.gov (United States)

    Sudarno; Juarsa, Mulya; Santosa, Kussigit; Deswandri; Sunaryo, Geni Rina

    2018-02-01

    In the nuclear reactor accident of Fukushima Daiichi in Japan, the damages of core and pressure vessel were caused by the failure of its active cooling system (diesel generator was inundated by tsunami). Thus researches on passive cooling system for Nuclear Power Plant are performed to improve the safety aspects of nuclear reactors. The FASSIP system (Passive System Simulation Facility) is an installation used to study the characteristics of passive cooling systems at nuclear power plants. The accuracy of sensor measurement of FASSIP system is essential, because as the basis for determining the characteristics of a passive cooling system. In this research, a sensor failure detection method for FASSIP system is developed, so the indication of sensor failures can be detected early. The method used is Principal Component Analysis (PCA) to reduce the dimension of the sensor, with the Squarred Prediction Error (SPE) and statistic Hotteling criteria for detecting sensor failure indication. The results shows that PCA method is capable to detect the occurrence of a failure at any sensor.

  12. Wear and Adhesive Failure of Al2O3 Powder Coating Sprayed onto AISI H13 Tool Steel Substrate

    Science.gov (United States)

    Amanov, Auezhan; Pyun, Young-Sik

    2016-07-01

    In this study, an alumina (Al2O3) ceramic powder was sprayed onto an AISI H13 hot-work tool steel substrate that was subjected to sanding and ultrasonic nanocrystalline surface modification (UNSM) treatment processes. The significance of the UNSM technique on the adhesive failure of the Al2O3 coating and on the hardness of the substrate was investigated. The adhesive failure of the coating sprayed onto sanded and UNSM-treated substrates was investigated by a micro-scratch tester at an incremental load. It was found, based on the obtained results, that the coating sprayed onto the UNSM-treated substrate exhibited a better resistance to adhesive failure in comparison with that of the coating sprayed onto the sanded substrate. Dry friction and wear property of the coatings sprayed onto the sanded and UNSM-treated substrates were assessed by means of a ball-on-disk tribometer against an AISI 52100 steel ball. It was demonstrated that the UNSM technique controllably improved the adhesive failure of the Al2O3 coating, where the critical load was improved by about 31%. Thus, it is expected that the application of the UNSM technique to an AISI H13 tool steel substrate prior to coating may delay the adhesive failure and improve the sticking between the coating and the substrate thanks to the modified and hardened surface.

  13. Detection of sensor failures in nuclear plants using analytic redundancy

    International Nuclear Information System (INIS)

    Kitamura, M.

    1980-01-01

    A method for on-line, nonperturbative detection and identification of sensor failures in nuclear power plants was studied to determine its feasibility. This method is called analytic redundancy, or functional redundancy. Sensor failure has traditionally been detected by comparing multiple signals from redundant sensors, such as in two-out-of-three logic. In analytic redundancy, with the help of an assumed model of the physical system, the signals from a set of sensors are processed to reproduce the signals from all system sensors

  14. Contribution to the physical study of sheath failure detections

    International Nuclear Information System (INIS)

    Mangin, Jean-Paul

    1968-11-01

    As the study of an installation aimed at the detection of sheath failure requires the knowledge of a great number of data related to all the fields of nuclear technology (fission mechanisms, sheath failure mechanisms, recoil of fission products, distribution of the heat transfer fluid in the reactor, techniques of measurement of beta and gamma neutrons, nuclear safety, and so on), this report aims at highlighting some specific issues, more particularly those related to sensors based on delayed neutrons. After having recalled the principles of sheath failure detection, the author presents the various aspects of the study of the formation of fission products and of their passage into the heat transfer fluid: detection by using delayed neutrons, detection by electrostatic collection, passage of fuel fission products into the coolant (recoil, corrosion, gaseous diffusion in the fuel), formation of fission products in the fuel (fission product efficiency). He reports the study of the transport of fission products by the coolant from their place of birth to the place of measurement. He presents the system of measurement by detection of delayed neutrons and by electrostatic collection, reports a sensitivity calculation, a background noise assessment, the determination of detection threshold, and the application of sensitivity and detection thresholds calculations [fr

  15. Detecting failure events in buildings: a numerical and experimental analysis

    OpenAIRE

    Heckman, V. M.; Kohler, M. D.; Heaton, T. H.

    2010-01-01

    A numerical method is used to investigate an approach for detecting the brittle fracture of welds associated with beam -column connections in instrumented buildings in real time through the use of time-reversed Green’s functions and wave propagation reciprocity. The approach makes use of a prerecorded catalog of Green’s functions for an instrumented building to detect failure events in the building during a later seismic event by screening continuous data for the presence of wavef...

  16. Clad failure detection in G 3 - operational feedback

    International Nuclear Information System (INIS)

    Plisson, J.

    1964-01-01

    After briefly reviewing the role and the principles of clad failure detection, the author describes the working conditions and the conclusions reached after 4 years operation of this installation on the reactor G 3. He mentions also the modifications made to the original installation as well as the tests carried out and the experiments under way. (author) [fr

  17. Penstock failure detection system at the 'Valsan' hydro power plant

    International Nuclear Information System (INIS)

    Georgescu, A M; Coşoiu, C I; Alboiu, N; Hlevca, D; Tataroiu, R; Popescu, O

    2012-01-01

    'Valsan' is a small Hydro Power Plant, 5 MW, situated at about 160 km north of Bucharest, Romania, on the small 'Valsan' river in a remote mountainous area. It is equipped with a single Francis turbine. The penstock is located in the access shaft of the HPP. 'Hidroelectrica', the Romanian company that operates the HPP, was trying to implement a remote penstock failure detection system. Starting from a classic hydraulic problem, the authors of the paper derived a method for failure detection and localization on the pipe. The method assumes the existence of 2 flow meters and 2 pressure transducers at the inlet and outlet of the pressurized pipe. Calculations have to be based on experimental values measured in a permanent regime for different values of the flow rate. The method was at first tested on a pipe, in the Hydraulic Laboratory of the Technical University of Civil Engineering Bucharest. Pipe failure was modelled by opening of a valve on a tee branch of the analyzed pipe. Experimental results were found to be in good agreement with theoretical ones. The penstock of the 'Valsan' HPP, was modelled in EPANET, in order to: i) test the method at a larger scale; ii) get the right flow and pressure transducers that are needed to implement it. At the request of 'Hidroelectrica' a routine that computes the efficiency of the turbine was added to the monitoring software. After the system was implemented, another series of measurements were performed at the site in order to validate it. Failure was modelled by opening an existing valve on a branch of the penstock. Detection of the failure was correct and almost instantaneous, while failure location was accurate within 5% of the total penstock length.

  18. Penstock failure detection system at the "Valsan" hydro power plant

    Science.gov (United States)

    Georgescu, A. M.; Coşoiu, C. I.; Alboiu, N.; Hlevca, D.; Tataroiu, R.; Popescu, O.

    2012-11-01

    "Valsan" is a small Hydro Power Plant, 5 MW, situated at about 160 km north of Bucharest, Romania, on the small "Valsan" river in a remote mountainous area. It is equipped with a single Francis turbine. The penstock is located in the access shaft of the HPP. "Hidroelectrica", the Romanian company that operates the HPP, was trying to implement a remote penstock failure detection system. Starting from a classic hydraulic problem, the authors of the paper derived a method for failure detection and localization on the pipe. The method assumes the existence of 2 flow meters and 2 pressure transducers at the inlet and outlet of the pressurized pipe. Calculations have to be based on experimental values measured in a permanent regime for different values of the flow rate. The method was at first tested on a pipe, in the Hydraulic Laboratory of the Technical University of Civil Engineering Bucharest. Pipe failure was modelled by opening of a valve on a tee branch of the analyzed pipe. Experimental results were found to be in good agreement with theoretical ones. The penstock of the "Valsan" HPP, was modelled in EPANET, in order to: i) test the method at a larger scale; ii) get the right flow and pressure transducers that are needed to implement it. At the request of "Hidroelectrica" a routine that computes the efficiency of the turbine was added to the monitoring software. After the system was implemented, another series of measurements were performed at the site in order to validate it. Failure was modelled by opening an existing valve on a branch of the penstock. Detection of the failure was correct and almost instantaneous, while failure location was accurate within 5% of the total penstock length.

  19. The application of the detection filter to aircraft control surface and actuator failure detection and isolation

    Science.gov (United States)

    Bonnice, W. F.; Wagner, E.; Motyka, P.; Hall, S. R.

    1985-01-01

    The performance of the detection filter in detecting and isolating aircraft control surface and actuator failures is evaluated. The basic detection filter theory assumption of no direct input-output coupling is violated in this application due to the use of acceleration measurements for detecting and isolating failures. With this coupling, residuals produced by control surface failures may only be constrained to a known plane rather than to a single direction. A detection filter design with such planar failure signatures is presented, with the design issues briefly addressed. In addition, a modification to constrain the residual to a single known direction even with direct input-output coupling is also presented. Both the detection filter and the modification are tested using a nonlinear aircraft simulation. While no thresholds were selected, both filters demonstrated an ability to detect control surface and actuator failures. Failure isolation may be a problem if there are several control surfaces which produce similar effects on the aircraft. In addition, the detection filter was sensitive to wind turbulence and modeling errors.

  20. The role of microstructure and phase distribution in the failure mechanisms and life prediction model for PSZ coatings

    Science.gov (United States)

    Sisson, R. D., Jr.; Sone, Ichiro; Biederman, R. R.

    1985-01-01

    Partially Stabilized Zirconia (PSZ) may become widely used for Thermal Barrier Coatings (TBC). Failure of these coatings can occur due to thermal fatigue in oxidizing atmospheres. The failure is due to the strains that develop due to thermal gradients, differences in thermal expansion coefficients, and oxidation of the bond coating. The role of microstructure and the cubic, tetragonal, and monoclinic phase distribution in the strain development and subsequent failure will be discussed. An X-ray diffraction technique for accurate determination of the fraction of each phase in PSZ will be applied to understanding the phase transformations and strain development. These results will be discussed in terms of developing a model for life prediction in PSZ coatings during thermal cycling.

  1. Incipient failure detection of space shuttle main engine turbopump bearings using vibration envelope detection

    Science.gov (United States)

    Hopson, Charles B.

    1987-01-01

    The results of an analysis performed on seven successive Space Shuttle Main Engine (SSME) static test firings, utilizing envelope detection of external accelerometer data are discussed. The results clearly show the great potential for using envelope detection techniques in SSME incipient failure detection.

  2. Humidity Detection Using Metal Organic Framework Coated on QCM

    KAUST Repository

    Kosuru, Lakshmoji

    2016-06-28

    Quartz crystal microbalance (QCM) coated with poly-4-vinylpyridine (PVP) and metal organic framework HKUST-1 are investigated and compared for humidity sensing. Drop casting method is employed to coat the PVP and HKUST-1 solutions onto the surface of a quartz crystal microbalance. The resonance frequencies of these sensors with varying relative humidity (RH) from 22% RH to 69% RH are measured using impedance analysis method. The sensitivity, humidity hysteresis, response, and recovery times of these sensors are studied. The sensitivities of uncoated, PVP, and HKUST-1 coated QCM sensors are 7 Hz, 48 Hz, and 720 Hz, respectively, in the range of 22% RH–69% RH. The extraction of desorption rate and adsorption energy associated with the adsorption and desorption of water molecules on these surfaces reveals that HKUST-1 has better sensing properties than PVP and uncoated QCM sensors. In this work, the HKUST-1 coated QCM is shown to be a promising material for moisture detection.

  3. Humidity Detection Using Metal Organic Framework Coated on QCM

    Directory of Open Access Journals (Sweden)

    Lakshmoji Kosuru

    2016-01-01

    Full Text Available Quartz crystal microbalance (QCM coated with poly-4-vinylpyridine (PVP and metal organic framework HKUST-1 are investigated and compared for humidity sensing. Drop casting method is employed to coat the PVP and HKUST-1 solutions onto the surface of a quartz crystal microbalance. The resonance frequencies of these sensors with varying relative humidity (RH from 22% RH to 69% RH are measured using impedance analysis method. The sensitivity, humidity hysteresis, response, and recovery times of these sensors are studied. The sensitivities of uncoated, PVP, and HKUST-1 coated QCM sensors are 7 Hz, 48 Hz, and 720 Hz, respectively, in the range of 22% RH–69% RH. The extraction of desorption rate and adsorption energy associated with the adsorption and desorption of water molecules on these surfaces reveals that HKUST-1 has better sensing properties than PVP and uncoated QCM sensors. In this work, the HKUST-1 coated QCM is shown to be a promising material for moisture detection.

  4. Fuzzy modeling of analytical redundancy for sensor failure detection

    International Nuclear Information System (INIS)

    Tsai, T.M.; Chou, H.P.

    1991-01-01

    Failure detection and isolation (FDI) in dynamic systems may be accomplished by testing the consistency of the system via analytically redundant relations. The redundant relation is basically a mathematical model relating system inputs and dissimilar sensor outputs from which information is extracted and subsequently examined for the presence of failure signatures. Performance of the approach is often jeopardized by inherent modeling error and noise interference. To mitigate such effects, techniques such as Kalman filtering, auto-regression-moving-average (ARMA) modeling in conjunction with probability tests are often employed. These conventional techniques treat the stochastic nature of uncertainties in a deterministic manner to generate best-estimated model and sensor outputs by minimizing uncertainties. In this paper, the authors present a different approach by treating the effect of uncertainties with fuzzy numbers. Coefficients in redundant relations derived from first-principle physical models are considered as fuzzy parameters and on-line updated according to system behaviors. Failure detection is accomplished by examining the possibility that a sensor signal occurred in an estimated fuzzy domain. To facilitate failure isolation, individual FDI monitors are designed for each interested sensor

  5. Sensor failure detection in dynamical systems by Kalman filtering methodology

    International Nuclear Information System (INIS)

    Ciftcioglu, O.

    1991-03-01

    Design of a sensor failure detection system by Kalman filtering methodology is described. The method models the process systems in state-space form, the information on each state being provided by relevant sensors present in the process system. Since the measured states are usually subject to noise, the estimation of the states optimally is an essential requirement. To this end the detection system comprises Kalman estimation filters, the number of which is equal to the number of states concerned. The estimated state of a particular signal in each filter is compared with the corresponding measured signal and difference beyond a predetermined bound is identified as failure, the sensor being identified/isolated as faulty. (author). 19 refs.; 8 figs.; 1 tab

  6. Development of failure detection system for gas-cooled reactor

    International Nuclear Information System (INIS)

    Feirreira, M.P.

    1990-01-01

    This work presents several kinds of Failure Detection Systems for Fuel Elements, stressing their functional principles and major applications. A comparative study indicates that the method of electrostatic precipitation of the fission gases Kr and Xe is the most efficient for fuel failure detection in gas-cooled reactors. A detailed study of the physical phenomena involved in electrostatic precipitation led to the derivation of an equation for the measured counting rate. The emission of fission products from the fuel and the ion recombination inside the chamber are evaluated. A computer program, developed to simulate the complete operation of the system, relates the counting rate to the concentration of Kr and Xe isotopes. The project of a mock-up is then presented. Finally, the program calculations are compared to experimental data, available from the literature, yielding a close agreement. (author)

  7. Optimally Robust Redundancy Relations for Failure Detection in Uncertain Systems,

    Science.gov (United States)

    1983-04-01

    particular applications. While the general methods provide the basis for what in principle should be a widely applicable failure detection methodology...modifications to this result which overcome them at no fundmental increase in complexity. 4.1 Scaling A critical problem with the criteria of the preceding...criterion which takes scaling into account L 2 s[ (45) As in (38), we can multiply the C. by positive scalars to take into account unequal weightings on

  8. Method of detecting fuel failure in FBR type reactor and method of estimating fuel failure position

    International Nuclear Information System (INIS)

    Sonoda, Yukio; Tamaoki, Tetsuo

    1989-01-01

    Noise components in a normal state contained in detection signals from delayed neutron monitors disposed to a coolant inlet, etc. of an intermediate heat exchanger are forecast by self-recurring model and eliminated, and resultant detection signals are monitored thereby detecting fuel failure high sensitivity. Subsequently, the reactor is controlled to a low power operation state and a new self-recurring model to the detection signals from the delayed neutron monitors are prepared. Then, noise components in this state are removed and control rods near the delayed neutron monitors are extracted in a short stroke successively to examine the change of response of the delayed neutron monitors. Accordingly, the failed position for each of the fuels can be estimated at a level of one fuel assembly or a level of several assemblies containing the above-mentioned fuel assembly. Since the fuel failure can be detected at a high sensitivity and the position can be estimated, diffusion of abnormality can be prevented and plant shutdown for fuel exchange can be minimized. (I.S.)

  9. Surface and Microstructural Failures of PET-Coated ECCS Plates by Salmon-Polymer Interaction

    Directory of Open Access Journals (Sweden)

    Ernesto Zumelzu

    2016-03-01

    Full Text Available The new types of knowledge-intensive, multilayer containers consist of steel plates protected against corrosion by nanometric electrolytic chromium (Cr0 and chromium oxide (Cr2O3 layers chemically bonded to polyethylene terephthalate (PET polymer coating to preserve food. It was observed that after emptying the cans, the salmon adhered to the polymer coating, changing its color, and that this adhesion increased with longer storage times. This work was aimed at determining the product-container interactions and their characterization by X-ray diffraction (XRD, confocal Raman and micro-Raman imaging and scanning electron microscopy (SEM analysis. The zones of adhesion showed surface changes, variations in crystallinity and microstructural degradation of the PET coating. In addition, localized damages altering the functional properties of the multilayer system were observed as microcracking in the chromium layers that protect the steel. The degradation undergone was evaluated and characterized at a surface and microstructural level to establish the failure mechanisms, which were mainly associated with the activity of the adhered muscle and its biochemical components. Finally, a recommendation is done to preserve the useful life and functionality of cans for the preservation and efficient use of resources with an impact on recycling and environmental conservancy.

  10. Development of a system for automatic detection of pellet failures

    International Nuclear Information System (INIS)

    Lavagnino, C.E.

    1996-01-01

    Nowadays, the failure controls in UO 2 pellets for Atucha and Embalse reactors are performed visually. In this work it is presented the first stage of the development of a system that allows an automatic approach to the task. For this purpose, the problem has been subdivided in three jobs: choosing the illumination environment, finding the algorithm that detects failures with user-defined tolerance and engineering the mechanic system that supports the desired manipulations of the pellets. In this paper, the former two are developed. a) Finding the illumination conditions that allow subtracting the failure from the normal element surface, knowing, in first place, the cylindrical characteristics of it and, as a consequence, the differences in the light reflection direction and, in second place, the texture differences in relation to the rectification type of the pellet. b) Writing a fast and simple algorithm that allows the identification of the failure following the production specifications. Examples of the developed algorithm are shown. (author). 4 refs

  11. Filter design for failure detection and isolation in the presence of modeling errors and disturbances

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Stoustrup, Jakob

    1996-01-01

    The design problem of filters for robust failure detection and isolation, (FDI) is addressed in this paper. The failure detection problem will be considered with respect to both modeling errors and disturbances. Both an approach based on failure detection observers as well as an approach based...

  12. Detection of wood failure by image processing method: influence of algorithm, adhesive and wood species

    Science.gov (United States)

    Lanying Lin; Sheng He; Feng Fu; Xiping Wang

    2015-01-01

    Wood failure percentage (WFP) is an important index for evaluating the bond strength of plywood. Currently, the method used for detecting WFP is visual inspection, which lacks efficiency. In order to improve it, image processing methods are applied to wood failure detection. The present study used thresholding and K-means clustering algorithms in wood failure detection...

  13. Assessment of NDE methods for detecting cracks and damage in environmental barrier coated CMC tested under tension

    Science.gov (United States)

    Abdul-Aziz, Ali; Wroblewski, Adam C.; Bhatt, Ramakrishna T.; Jaskowiak, Martha H.; Gorican, Daniel; Rauser, Richard W.

    2015-03-01

    For validating physics based analytical models predicting spallation life of environmental barrier coating (EBC) on fiber reinforced ceramic matrix composites, the fracture strength of EBC and kinetics of crack growth in EBC layers need to be experimentally determined under engine operating conditions. In this study, a multi layered barium strontium aluminum silicate (BSAS) based EBC-coated, melt infiltrated silicon carbide fiber reinforced silicon carbide matrix composite (MI SiC/SiC) specimen was tensile tested at room temperature. Multiple tests were performed on a single specimen with increasing predetermined stress levels until final failure. During loading, the damage occurring in the EBC was monitored by digital image correlation (DIC). After unloading from the predetermined stress levels, the specimen was examined by optical microscopy and computed tomography (CT). Results indicate both optical microscopy and CT could not resolve the primary or secondary cracks developed during tensile loading until failure. On the other hand, DIC did show formation of a primary crack at ~ 50% of the ultimate tensile strength and this crack grew with increasing stress and eventually led to final failure of the specimen. Although some secondary cracks were seen in the DIC strain plots prior to final failure, the existence of these cracks were not confirmed by other methods. By using a higher resolution camera, it is possible to improve the capability of DIC in resolving secondary cracks and damage in coated specimen tested at room temperature, but use of DIC at high temperature requires significant development. Based on the current data, it appears that both optical microscopy and CT do not offer any hope for detecting crack initiation or determining crack growth in EBC coated CMC tested at room or high temperatures after the specimen has been unloaded. Other methods such as, thermography and optical/SEM of the polished cross section of EBC coated CMC specimens stressed to

  14. Failure characteristics and mechanisms of EB-PVD TBCs with Pt-modified NiAl bond coats

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Le; Mukherjee, Sriparna; Huang, Ke; Park, Young Whan; Sohn, Yongho, E-mail: Yongho.Sohn@ucf.edu

    2015-06-18

    Microstructural evolution and failure characteristics/mechanisms were investigated for thermal barrier coatings that consist of electron beam physical vapor deposited ZrO{sub 2}−8 wt% Y{sub 2}O{sub 3} (YSZ) topcoat, Pt-modified nickel aluminide, (Ni,Pt)Al bond coat, and CMSX-4 superalloy substrate with furnace cycling at 1100 °C with 1-h dwell. Photo stimulated luminescence spectroscopy, scanning electron microscopy equipped with X-ray energy dispersive spectroscopy and transmission electron microscopy were employed to examine the residual stress of the thermally grown oxide (TGO) and microstructural changes. For comparison, (Ni,Pt)Al bond coat on CMSX-4 without the YSZ topcoat was also characterized. The TGO grew faster for the YSZ-coated (Ni,Pt)Al bond coat than the (Ni,Pt)Al coating without the YSZ topcoat. Correspondingly, the β-to-γ′/martensite formation in the (Ni,Pt)Al bond coat occurred faster on the YSZ-coated (Ni,Pt)Al bond coat. However the rumpling occurred much faster and with larger amplitude on the (Ni,Pt)Al coating without the YSZ topcoat. Still, the rumpling at the TGO/bond coat interface caused crack initiation as early as 10 thermal cycles, decohesion at the YSZ/TGO interface, and eventual spallation failure primarily through the TGO/bond coat interface. The magnitude of compressive residual stress in the TGO showed an initial increase up to 3−4 GPa followed by a gradual decrease. The rate of stress relaxation was much quicker for the TGO scale without the YSZ topcoat with distinctive relief corresponding to the cracking at the top of geometrical ridges associated with the (Ni,Pt)Al bond coat. The maximum elastic energy for the TGO scale was estimated at 90 J/m{sup 2} at 50% of its lifetime (N{sub f}=545 cycles). The YSZ presence/adhesion to the TGO scale is emphasized to minimize the undulation of the TGO/bond coat interface, i.e., decohesion at the YSZ/TGO scale accelerates the rumpling and crack-coalescence at the TGO/bond coat

  15. NATO Symposium on Human Detection and Diagnosis of System Failures

    CERN Document Server

    Rouse, William

    1981-01-01

    This book includes all of the papers presented at the NATO Symposium on Human Detection and Diagnosis of System Failures held at Roskilde, Denmark on August 4-8, 1980. The Symposium was sponsored by the Scientific Affairs Division of NATO and the Rise National Laboratory of Denmark. The goal of the Symposium was to continue the tradition initiated by the NATO Symposium on Monitoring Behavior and Supervisory Control held in Berchtesgaden, F .R. Germany in 1976 and the NATO Symposium on Theory and Measurement of Mental Workload held in Mati, Greece in 1977. To this end, a group of 85 psychologists and engineers coming from industry, government, and academia convened to discuss, and to generate a "state-of-the-art" consensus of the problems and solutions associated with the human IS ability to cope with the increasing scale of consequences of failures within complex technical systems. The Introduction of this volume reviews their findings. The Symposium was organized to include brief formal presentations of pape...

  16. Detection of failures of axle-bearings of railway vehicles

    Directory of Open Access Journals (Sweden)

    Bižić Milan B.

    2016-01-01

    Full Text Available The failure of axle-bearing is one of the most common causes of derailments of railway vehicles which are usually accompanied by huge material damage and human casualties. Modern railways are working intensively on the development and implementation of appropriate systems for early detection of axlebearing malfunctions, which are typically manifested by increasing of its temperature. The most common approach is based on the use of wayside systems or checkpoints located in certain places along the track. There is also an innovative approach that involves using the system for continuous measuring and online monitoring of axle-boxes temperature. The main aim is to provide early detection of malfunctions of the axle-bearing and prevention of the potential derailment. This paper analyses the existing solutions for the detection of axle-bearings malfunctions with special emphasis on the working principle and the main advantages and disadvantages. The paper presents the basics of the one newly developed wireless measuring system for on-line monitoring of axle-boxes temperature. The measuring system was tested in real conditions and can be successfully applied to the commercial railway vehicles. The main conclusion is that systems for on-line monitoring of axle-bearings temperatures are far more efficient than wayside systems. Obtained results may be important for those who deal with these and similar problems, problems of development, exploitation and maintenance of railway vehicles, strategies, regulations, etc.

  17. Studies on fuel failure detection in Rikkyo Research Reactor

    International Nuclear Information System (INIS)

    Matsuura, T.; Hayashi, S.H.; Harasawa, S.; Tomura, K.

    1992-01-01

    Studies on fuel failure detection have been made since 1986 in Rikkyo Research Reactor. One of the methods is the monitoring of the trace concentration of fission products appearing in the air on the surface of the water tank of the reactor. The interested radionuclides here are 89 Rb and 138 Cs, which are the daughter nuclides of the FP rare gas nuclides, 89 Kr and 138 Xe, respectively and have the half lives of 15.2 min and 32.2 min respectively. They are detected on a filter paper attached on a conventional dust sampler, by sucking the air of the surface of the water for 15 ∼ 30 min during reactor operation (100 kW). In this presentation are reported the results of an attempt to increase the sensitivity of detecting these nuclides by introducing nitrogen gas bubbles into the water. The bubbling of the gas increased the sensitivity as much as several times compared with the case without bubbling. These measurements are giving us the 'background' concentration, the order of which is almost unchanged for these several years, --in 10 -6 Bq/cm 3 . The origin of these nuclides is considered to be not from the fuel but from the uranium contained as an impurity in the reactor material in the core. (author)

  18. Performance limits of coated particle fuel. Part II. Mechanical failure of coated particles due to internal gas pressure and kernel swelling

    Energy Technology Data Exchange (ETDEWEB)

    Hick, H.; Nabielek, H.; Harrison, T. A.

    1973-10-15

    This report presents a summary of experimental results and their theoretical explanation with regard to the "Pressure Failure" of coated particle fuel. While the experimental results refer mainly to the Dragon Reference Particle as proposed for typical Low Enriched Homogeneous Prismatic Steam Cycle HTR Power Reactors, the theoretical understanding of the phenomena and the mathematical models for their description are not limited to a specific design line.

  19. Coating of carbon nanotube fibers: variation of tensile properties, failure behavior and adhesion strength

    Directory of Open Access Journals (Sweden)

    Edith eMäder

    2015-07-01

    Full Text Available An experimental study of the tensile properties of CNT fibers and their interphasial behavior in epoxy matrices is reported. One of the most promising applications of CNT fibers is their use as reinforcement in multifunctional composites. For this purpose, an increase of the tensile strength of the CNT fibers in unidirectional composites as well as strong interfacial adhesion strength is desirable. However, the mechanical performance of the CNT fiber composites manufactured so far is comparable to that of commercial fiber composites. The interfacial properties of CNT fiber/polymer composites have rarely been investigated and provided CNT fiber/epoxy interfacial shear strength of 14.4 MPa studied by the microbond test.In order to improve the mechanical performance of the CNT fibers, an epoxy compatible coating with nano-dispersed aqueous based polymeric film formers and low viscous epoxy resin, respectively, was applied. For impregnation of high homogeneity, low molecular weight epoxy film formers and polyurethane film formers were used. The aqueous based epoxy film formers were not crosslinked and able to interdiffuse with the matrix resin after impregnation. Due to good wetting of the individual CNT fibers by the film formers, the degree of activation of the fibers was improved leading to increased tensile strength and Young’s modulus. Cyclic tensile loading and simultaneous determination of electric resistance enabled to characterize the fiber’s durability in terms of elastic recovery and hysteresis.The pull-out tests and SEM study reveal different interfacial failure mechanisms in CNT fiber/epoxy systems for untreated and film former treated fibers, on the one hand, and epoxy resin treated ones, on the other hand. The epoxy resin penetrated between the CNT bundles in the reference or film former coated fiber, forming a relatively thick CNT/epoxy composite layer and thus shifting the fracture zone within the fiber. In contrast to this

  20. Study the polymer coating for detecting and surface decontamination of uranium

    International Nuclear Information System (INIS)

    Pham Thi Quynh Luong; Nguyen Van Chinh

    2011-01-01

    Strippable polymer coating is one of the methods for effective surface decontamination. It has been developed in both detecting and removing the radioactive isotope and heavy metal elements from contaminated surfaces. A polymer coating is produced to be sprayed or brushed on contaminated material of uranium. The places of U contamination is shown by color change of polymer coating. As the polymer coating is dried up to form a strong film, the contaminations are absorbed in to the coating and contaminated surfaces are cleaned by removing the film. (author)

  1. Failure Analysis of Multilayered Suspension Plasma-Sprayed Thermal Barrier Coatings for Gas Turbine Applications

    Science.gov (United States)

    Gupta, M.; Markocsan, N.; Rocchio-Heller, R.; Liu, J.; Li, X.-H.; Östergren, L.

    2018-02-01

    Improvement in the performance of thermal barrier coatings (TBCs) is one of the key objectives for further development of gas turbine applications. The material most commonly used as TBC topcoat is yttria-stabilized zirconia (YSZ). However, the usage of YSZ is limited by the operating temperature range which in turn restricts the engine efficiency. Materials such as pyrochlores, perovskites, rare earth garnets are suitable candidates which could replace YSZ as they exhibit lower thermal conductivity and higher phase stability at elevated temperatures. The objective of this work was to investigate different multilayered TBCs consisting of advanced topcoat materials fabricated by suspension plasma spraying (SPS). The investigated topcoat materials were YSZ, dysprosia-stabilized zirconia, gadolinium zirconate, and ceria-yttria-stabilized zirconia. All topcoats were deposited by TriplexPro-210TM plasma spray gun and radial injection of suspension. Lifetime of these samples was examined by thermal cyclic fatigue and thermal shock testing. Microstructure analysis of as-sprayed and failed specimens was performed with scanning electron microscope. The failure mechanisms in each case have been discussed in this article. The results show that SPS could be a promising route to produce multilayered TBCs for high-temperature applications.

  2. Relationship between ion transport and the failure behavior of epoxy resin coatings

    International Nuclear Information System (INIS)

    Dong, Yuhua; Zhou, Qiong

    2014-01-01

    Highlights: •An epoxy resin-Q345 system with a sandwich structure was prepared. •Cl − ions permeated into epoxy resin coating prior to K + ions. •Free volume size and PAL increased when the coating was immersed into the solution. -- Abstract: An epoxy resin coating with a sandwich structure was prepared to investigate ion transport behavior in the coating. The macro- and micro- appearance of the coating immersed in 5 wt.% KCl solutions was observed by stereomicroscopy, scanning electron microscopy equipped with an energy dispersive spectrometer. The electrochemical property of the coating was characterized by electrochemical impedance spectroscopy, and change of free volume after immersion was characterized by positron annihilation lifetime spectroscopy. The results indicated that Cl − ions permeated into the coating prior to K + ions, the free volume size and positron annihilation lifetime of the coating increased during immersion

  3. Online Real-Time Tribology Failure Detection System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The investigation of the coating friction as a function of time is important to monitor the ball bearing heath. Despite the importance of the subject mater, there is...

  4. A Molecularly Imprinted Polymer (MIP)-Coated Microbeam MEMS Sensor for Chemical Detection

    Science.gov (United States)

    2015-09-01

    ARL-RP-0536 ● SEP 2015 US Army Research Laboratory A Molecularly Imprinted Polymer (MIP)- Coated Microbeam MEMS Sensor for...ARL-RP-0536 ● SEP 2015 US Army Research Laboratory A Molecularly Imprinted Polymer (MIP)- Coated Microbeam MEMS Sensor for Chemical...TITLE AND SUBTITLE A Molecularly Imprinted Polymer (MIP)-Coated Microbeam MEMS Sensor for Chemical Detection 5a. CONTRACT NUMBER 5b. GRANT NUMBER

  5. In-line 3D print failure detection using computer vision

    DEFF Research Database (Denmark)

    Lyngby, Rasmus Ahrenkiel; Wilm, Jakob; Eiríksson, Eyþór Rúnar

    2017-01-01

    Here we present our findings on a novel real-time vision system that allows for automatic detection of failure conditions that are considered outside of nominal operation. These failure modes include warping, build plate delamination and extrusion failure. Our system consists of a calibrated came...

  6. Filter Design for Failure Detection and Isolation in the Presence of Modeling Erros and Disturbances

    DEFF Research Database (Denmark)

    Stoustrup, Jakob; Niemann, Hans Henrik

    1996-01-01

    The design problem of filters for robust Failure Detectionand Isolation, (FDI) is addressed in this paper. The failure detectionproblem will be considered with respect to both modeling errors anddisturbances. Both an approach based on failure detection observes aswell as an approach based...

  7. A New Detecting Technology for External Anticorrosive Coating Defects of Pipelines Based on Ultrasonic Guided Wave

    Science.gov (United States)

    Liu, Shujun; Zuo, Yonggang; Zhang, Zhen

    2018-01-01

    The external anticorrosive coating is the shelter for preventing steel pipelines from Corrosive damage. A number of pipelines face severe corrosive problems for the performance decrease of the coating, especially during long-term services, which usually led to safety accidents. To solve the detection problem about the defect of anticorrosive layer for pipeline, a new detection method for anticorrosive layer of pipelines based on Ultrasonic Guided Wave was proposed in the paper. The results from the investigation show a possibility of using the Ultrasonic Guided Wave method for detecting the damage of pipeline’s External Anticorrosive Coating.

  8. Orthogonal series generalized likelihood ratio test for failure detection and isolation. [for aircraft control

    Science.gov (United States)

    Hall, Steven R.; Walker, Bruce K.

    1990-01-01

    A new failure detection and isolation algorithm for linear dynamic systems is presented. This algorithm, the Orthogonal Series Generalized Likelihood Ratio (OSGLR) test, is based on the assumption that the failure modes of interest can be represented by truncated series expansions. This assumption leads to a failure detection algorithm with several desirable properties. Computer simulation results are presented for the detection of the failures of actuators and sensors of a C-130 aircraft. The results show that the OSGLR test generally performs as well as the GLR test in terms of time to detect a failure and is more robust to failure mode uncertainty. However, the OSGLR test is also somewhat more sensitive to modeling errors than the GLR test.

  9. Gas sensors for ammonia detection based on polyaniline-coated multi-wall carbon nanotubes

    International Nuclear Information System (INIS)

    He Lifang; Jia Yong; Meng Fanli; Li Minqiang; Liu Jinhuai

    2009-01-01

    Polyaniline-coated multi-wall carbon nanotubes (PANI-coated MWNTs) were prepared by in situ polymerization method. Field emission scanning electron microscopy, transmission electron microscopy, Raman spectroscopy, and thermogravimetric analysis were used to characterize the as-prepared PANI-coated MWNTs. Obtained results indicated that PANI was uniformly coated on MWNTs, and the thickness of the coatings can be controlled by changing the weight ratios of aniline monomer and MWNTs in the polymerization process. Sensors were fabricated by spin-coating onto pre-patterned electrodes, and ammonia gas sensing properties of the as-prepared PANI-coated MWNTs were studied. The results showed a good response and reproducibility towards ammonia at room temperature. In addition, PANI-coated MWNTs exhibited a linear response to ammonia in the range of 0.2-15 ppm. The effects of the thickness of PANI coatings on the gas sensing properties were also investigated in detail. The results suggest a potential application of PANI-coated MWNTs in gas sensor for detecting ammonia.

  10. On experiments to detect possible failures on relativity theory

    International Nuclear Information System (INIS)

    Rodrigues Junior, W.A.; Tiomno, J.

    1982-01-01

    Conditions under which is expected the failure of Einstein's Relativity are analysed. A complete analysis of a recently proposed experiment by Kolen-Torr is also given showing that it must give a negative result. (Author) [pt

  11. Method and apparatus for measuring on-line failure of turbine thermal barrier coatings

    Science.gov (United States)

    Zombo, Paul J.; Lemieux, Dennis; Diatzikis, Evangelos

    2010-04-06

    A method of remotely monitoring the radiant energy (6) emitted from a turbine component such as a turbine blade (1) having a low-reflective surface coating (3) which may be undergoing potential degradation is used to determine whether erosion, spallation, delamination, or the like, of the coating (3) is occurring.

  12. FFTF fuel failure detection and characterization by cover gas monitoring. Final report

    International Nuclear Information System (INIS)

    Miller, W.C.; Holt, F.E.

    1977-01-01

    The Fast Flux Test Facility (FFTF) will include a Fuel Failure Monitoring (FFM) System designed to detect, characterize, and locate fuel and absorber pin failures (i.e., cladding breaches) using a combination of delayed neutron detection, cover gas radioisotope monitoring, and gas tagging. During the past several years the Hanford Engineering Development Laboratory has been involved in the development, design, procurement, and installation of this integrated system. The paper describes one portion of the FFM System, the Cover Gas Monitoring System (CGMS), which has the primary function of fuel failure detection and characterization in the FFTF. By monitoring the various radioisotopes in the cover gas, the CGMS will both detect fuel and absorber pin failures and characterize those failures as to magnitude and severity

  13. Proof-testing strategies induced by dangerous detected failures of safety-instrumented systems

    International Nuclear Information System (INIS)

    Liu, Yiliu; Rausand, Marvin

    2016-01-01

    Some dangerous failures of safety-instrumented systems (SISs) are detected almost immediately by diagnostic self-testing as dangerous detected (DD) failures, whereas other dangerous failures can only be detected by proof-testing, and are therefore called dangerous undetected (DU) failures. Some items may have a DU- and a DD-failure at the same time. After the repair of a DD-failure is completed, the maintenance team has two options: to perform an insert proof test for DU-failure or not. If an insert proof test is performed, it is necessary to decide whether the next scheduled proof test should be postponed or performed at the scheduled time. This paper analyzes the effects of different testing strategies on the safety performance of a single channel of a SIS. The safety performance is analyzed by Petri nets and by approximation formulas and the results obtained by the two approaches are compared. It is shown that insert testing improves the safety performance of the channel, but the feasibility and cost of the strategy may be a hindrance to recommend insert testing. - Highlights: • Identify the tests induced by detected failures. • Model the testing strategies following DD-failures. • Propose analytical formulas for effects of strategies. • Simulate and verify the proposed models.

  14. Analyses Of Techniques On Structural Fatigue Failure Detection ...

    African Journals Online (AJOL)

    Machines and structures are subjected to variable loading conditions where the stress cycle does not remain the same during the operation of the machine. Fatigue is undoubtedly one of the most serious of all causes of breakdowns of machines and structures which results in sudden failures. The use of the time domain ...

  15. Design of fuel failure detection system for multipurpose reactor GA. Siwabessy

    International Nuclear Information System (INIS)

    Sujalmo Saiful; Kuntoro Iman; Sato, Mitsugu; Isshiki, Masahiko.

    1992-01-01

    A fuel failure detection system (FFDS) has been designed for the Reactor GA. Siwabessy. The FFDS is aimed to detect fuel failure by observing delayed neutron released by fission products such as N-17, I-137, Br-87 and Br-88 in the primary cooling system. The delayed neutrons will be detected by using four neutron detectors, type BF-3, which are located inside a Sampling Tank. The detector location has been determined and the location is associated with the transit time from the reactor core outlet to the Sampling Tank, which is approximately 60 seconds. The neutron detection efficiency was calculated by using a computer code named MORSE. The FFDS has the capability to detect as quickly as possible, even a small failure of a fuel element occurring in the reactor core. Therefore the presence of FFDS in a reactor must be considered, in order to prevent further progress if the fuel failure occurs. (author)

  16. Failure detection in high-performance clusters and computers using chaotic map computations

    Science.gov (United States)

    Rao, Nageswara S.

    2015-09-01

    A programmable media includes a processing unit capable of independent operation in a machine that is capable of executing 10.sup.18 floating point operations per second. The processing unit is in communication with a memory element and an interconnect that couples computing nodes. The programmable media includes a logical unit configured to execute arithmetic functions, comparative functions, and/or logical functions. The processing unit is configured to detect computing component failures, memory element failures and/or interconnect failures by executing programming threads that generate one or more chaotic map trajectories. The central processing unit or graphical processing unit is configured to detect a computing component failure, memory element failure and/or an interconnect failure through an automated comparison of signal trajectories generated by the chaotic maps.

  17. A formal language to describe a wide class of failure detection and signal validation procedures

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A. [Hungarian Academy of Sciences, Budapest (Hungary). Atomic Energy Research Inst.

    1996-01-01

    In the present article we make the first step towards the implementation of a user-friendly, object-oriented system devoted to failure detection and signal validation purposes. After overviewing different signal modelling, residual making and hypothesis testing procedures, a mathematical tool is suggested to describe a general failure detection problem. Three different levels of the abstraction are distinguished; direct examination, preliminary decision support mechanism and indirect examination. Possible scenarios are introduced depending both on the objective properties of the investigated signal and the particular requirements prescribed by the expert himself. Finally it is showed how to build up systematically a complete, general failure detection procedure. (author).

  18. Analytical Study of different types Of network failure detection and possible remedies

    Science.gov (United States)

    Saxena, Shikha; Chandra, Somnath

    2012-07-01

    Faults in a network have various causes,such as the failure of one or more routers, fiber-cuts, failure of physical elements at the optical layer, or extraneous causes like power outages. These faults are usually detected as failures of a set of dependent logical entities and the links affected by the failed components. A reliable control plane plays a crucial role in creating high-level services in the next-generation transport network based on the Generalized Multiprotocol Label Switching (GMPLS) or Automatically Switched Optical Networks (ASON) model. In this paper, approaches to control-plane survivability, based on protection and restoration mechanisms, are examined. Procedures for the control plane state recovery are also discussed, including link and node failure recovery and the concepts of monitoring paths (MPs) and monitoring cycles (MCs) for unique localization of shared risk linked group (SRLG) failures in all-optical networks. An SRLG failure is a failure of multiple links due to a failure of a common resource. MCs (MPs) start and end at same (distinct) monitoring location(s). They are constructed such that any SRLG failure results in the failure of a unique combination of paths and cycles. We derive necessary and sufficient conditions on the set of MCs and MPs needed for localizing an SRLG failure in an arbitrary graph. Procedure of Protection and Restoration of the SRLG failure by backup re-provisioning algorithm have also been discussed.

  19. Surface Cracking and Interface Reaction Associated Delamination Failure of Thermal and Environmental Barrier Coatings

    National Research Council Canada - National Science Library

    Zhu, Dongming

    2003-01-01

    ...%Y2O3 and mullite/BSAS/Si thermal and environmental barrier coating system on SiC/SiC ceramic matrix composites were characterized after long-term combined laser thermal gradient and furnace cyclic...

  20. THz Imaging as a Method to Detect Defects of Aeronautical Coatings

    Science.gov (United States)

    Catapano, I.; Soldovieri, F.; Mazzola, L.; Toscano, C.

    2017-10-01

    Ice adhesion over critical aircraft surfaces is a serious potential hazard that runs the risk of causing accidents. To face this issue, the design and diagnostics of new multifunctional coatings with icephobic and aesthetical properties are demanded. In particular, diagnostic tools, capable of characterizing coating surface finishing and its defects, are needed. In this paper, terahertz (THz) imaging is considered as a high-resolution diagnostic tool useful for contactless surveys providing information on surface defects and material inner structure. Therefore, two composite specimens, one covered by a classical commercial livery coating and the other one by a new multifunctional coating with icephobic properties, are investigated by THz surveys carried out in normal environmental conditions of pressure and temperature. The results, obtained by processing the raw data properly, corroborate that THz imaging allows us to detect variations of the coating thickness, to localize hidden anomalies as well as to characterize surface defects at millimetric scale.

  1. Multidrug-resistant tuberculosis treatment failure detection depends on monitoring interval and microbiological method

    Science.gov (United States)

    White, Richard A.; Lu, Chunling; Rodriguez, Carly A.; Bayona, Jaime; Becerra, Mercedes C.; Burgos, Marcos; Centis, Rosella; Cohen, Theodore; Cox, Helen; D'Ambrosio, Lia; Danilovitz, Manfred; Falzon, Dennis; Gelmanova, Irina Y.; Gler, Maria T.; Grinsdale, Jennifer A.; Holtz, Timothy H.; Keshavjee, Salmaan; Leimane, Vaira; Menzies, Dick; Milstein, Meredith B.; Mishustin, Sergey P.; Pagano, Marcello; Quelapio, Maria I.; Shean, Karen; Shin, Sonya S.; Tolman, Arielle W.; van der Walt, Martha L.; Van Deun, Armand; Viiklepp, Piret

    2016-01-01

    Debate persists about monitoring method (culture or smear) and interval (monthly or less frequently) during treatment for multidrug-resistant tuberculosis (MDR-TB). We analysed existing data and estimated the effect of monitoring strategies on timing of failure detection. We identified studies reporting microbiological response to MDR-TB treatment and solicited individual patient data from authors. Frailty survival models were used to estimate pooled relative risk of failure detection in the last 12 months of treatment; hazard of failure using monthly culture was the reference. Data were obtained for 5410 patients across 12 observational studies. During the last 12 months of treatment, failure detection occurred in a median of 3 months by monthly culture; failure detection was delayed by 2, 7, and 9 months relying on bimonthly culture, monthly smear and bimonthly smear, respectively. Risk (95% CI) of failure detection delay resulting from monthly smear relative to culture is 0.38 (0.34–0.42) for all patients and 0.33 (0.25–0.42) for HIV-co-infected patients. Failure detection is delayed by reducing the sensitivity and frequency of the monitoring method. Monthly monitoring of sputum cultures from patients receiving MDR-TB treatment is recommended. Expanded laboratory capacity is needed for high-quality culture, and for smear microscopy and rapid molecular tests. PMID:27587552

  2. Operation experiences of JOYO fuel failure detection system

    International Nuclear Information System (INIS)

    Tamura, Seiji; Hikichi, Takayoshi; Rindo, Hiroshi.

    1982-01-01

    Monitoring of fuel failure in the experimental fast reactor JOYO is provided by two different methods, which are cover gas monitoring (FFDCGM) by means of a precipitator, and delayed neutron monitoring (FFDDNM) by means of neutron detectors. The interpretation of signals which were obtained during the reactor operation for performance testings, was performed. The countrate of the CGM is approximately 120 cps at 75MW operation, whose sources are due to Ne 23 , Ar 41 , and Na 24 . And the countrate of the DNM is approximately 2300 cps at 75MW operation which is mainly due to leakage neutron from the core. With those background of the systems, alarm level for monitoring was set at several times of each background level. The reactor has been operated for 5 years, the burn-up of the fuel is 40,000 MWD/T at the most. No trace of any fuel failure has been observed. The fact is also proven by the results of cover gas and sodium sampling analysis. In order to evaluate sensitivity of the FFD systems, a preliminary simulation study has been performed. According to the results, a signal level against one pin failure of 0.5 mm 2 hole may exceed the alarm level of the FFDCGM system. (author)

  3. Smart Multifunctional Coatings for Corrosion Detection and Control in the Aerospace Industry

    Science.gov (United States)

    Calle, Luz Marina

    2015-01-01

    Nearly all metals and their alloys are subject to corrosion that causes them to lose their structural integrity or other critical functionality. It is essential to detect corrosion when it occurs, and preferably at its early stage, so that action can be taken to avoid structural damage or loss of function. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to indicate it and control it.

  4. Detection of smaller Jc region and damage in YBCO coated conductors by using permanent magnet method

    International Nuclear Information System (INIS)

    Hattori, K.; Saito, A.; Takano, Y.; Suzuki, T.; Yamada, H.; Takayama, T.; Kamitani, A.; Ohshima, S.

    2011-01-01

    We developed a non-destructive method for measuring the critical current density (J c ) in YBCO-coated conductors by using a permanent magnet (Sm 2 Co 17 ). J c could be determined from the repulsive force (F r ) generated between a permanent magnet and a coated conductor where shielding current flows. We also examined the influence of damage to the film on the J c distribution. The measured F r when the permanent magnet approached the cut part was smaller than that of the undamaged area. We developed a non-destructive method for measuring the critical current density (J c ) in YBCO-coated conductors by using a permanent magnet (Sm 2 Co 17 ). J c could be determined from the repulsive force (F r ) generated between a permanent magnet and a coated conductor where shielding current flows. We tried to detect a smaller J c region in the coated conductor by using the system. The J c distribution could be determined without influence from the thick copper film on YBCO thin film. We also examined the influence of damage to the film on the J c distribution. The surface of the coated conductors was cut by using a knife. The measured F r when the permanent magnet approached the cut part was smaller than that of the undamaged area. This J c measurement technique will be useful for detecting smaller J c regions and defects in coated conductors.

  5. Investigations of surface coatings to reduce memory effect in plastic scintillator detectors used for radioxenon detection

    International Nuclear Information System (INIS)

    Blaeckberg, L.; Fay, A.; Jogi, I.; Biegalski, S.; Boman, M.; Elmgren, K.; Fritioff, T.; Johansson, A.; Martensson, L.; Nielsen, F.; Ringbom, A.; Rooth, M.; Sjoestrand, H.; Klintenberg, M.

    2011-01-01

    In this work Al 2 O 3 and SiO 2 coatings are tested as Xe diffusion barriers on plastic scintillator substrates. The motivation is improved beta-gamma coincidence detection systems, used to measure atmospheric radioxenon within the verification regime of the Comprehensive Nuclear-Test-Ban Treaty. One major drawback with the current setup of these systems is that the radioxenon tends to diffuse into the plastic scintillator material responsible for the beta detection, resulting in an unwanted memory effect. Here, coatings with thicknesses between 20 and 900 nm have been deposited onto plastic scintillators, and investigated using two different experimental techniques. The results show that all tested coatings reduce the Xe diffusion into the plastic. The reduction is observed to increase with coating thickness for both coating materials. The 425 nm Al 2 O 3 coating is the most successful one, presenting a diffusion reduction of a factor 100, compared to uncoated plastic. In terms of memory effect reduction this coating is thus a viable solution to the problem in question.

  6. Investigations of surface coatings to reduce memory effect in plastic scintillator detectors used for radioxenon detection

    Science.gov (United States)

    Bläckberg, L.; Fay, A.; Jõgi, I.; Biegalski, S.; Boman, M.; Elmgren, K.; Fritioff, T.; Johansson, A.; Mårtensson, L.; Nielsen, F.; Ringbom, A.; Rooth, M.; Sjöstrand, H.; Klintenberg, M.

    2011-11-01

    In this work Al2O3 and SiO2 coatings are tested as Xe diffusion barriers on plastic scintillator substrates. The motivation is improved beta-gamma coincidence detection systems, used to measure atmospheric radioxenon within the verification regime of the Comprehensive Nuclear-Test-Ban Treaty. One major drawback with the current setup of these systems is that the radioxenon tends to diffuse into the plastic scintillator material responsible for the beta detection, resulting in an unwanted memory effect. Here, coatings with thicknesses between 20 and 900 nm have been deposited onto plastic scintillators, and investigated using two different experimental techniques. The results show that all tested coatings reduce the Xe diffusion into the plastic. The reduction is observed to increase with coating thickness for both coating materials. The 425 nm Al2O3 coating is the most successful one, presenting a diffusion reduction of a factor 100, compared to uncoated plastic. In terms of memory effect reduction this coating is thus a viable solution to the problem in question.

  7. Detection of DNA hybridization using graphene-coated black phosphorus surface plasmon resonance sensor

    Science.gov (United States)

    Pal, Sarika; Verma, Alka; Raikwar, S.; Prajapati, Y. K.; Saini, J. P.

    2018-05-01

    In this paper, graphene-coated black phosphorus at the metal surface for the detection of DNA hybridization event is numerically demonstrated. The strategy consists of placing the sensing medium on top of black phosphorus-graphene-coated SPR which interfaces with phosphate-buffered saline solution carrying single-stranded DNA. Upon hybridization with its complementary DNA, desorption of the nanostructures takes place and thus enables the sensitive detection of the DNA hybridization event. The proposed sensor exhibits a sensitivity (125 ο/RIU), detection accuracy (0.95) and quality factor (13.62 RIU-1) for complementary DNA. In comparison with other reported papers, our suggested sensor provides much better performance. Thus, this label-free DNA detection platform should spur off new interest towards the use of black phosphorus-graphene-coated SPR interfaces.

  8. Molecular diagnosis of toxoplasmosis: value of the buffy coat for the detection of circulating Toxoplasma gondii.

    Science.gov (United States)

    Brenier-Pinchart, Marie-Pierre; Capderou, Elodie; Bertini, Rose-Laurence; Bailly, Sébastien; Fricker-Hidalgo, Hélène; Varlet-Marie, Emmanuelle; Murat, Jean-Benjamin; Sterkers, Yvon; Touafek, Fériel; Bastien, Patrick; Pelloux, Hervé

    2015-08-01

    Early detection of Toxoplasma tachyzoites circulating in blood using PCR is recommended for immunosuppressed patients at high risk for disseminated toxoplasmosis. Using a toxoplasmosis mouse model, we show that the sensitivity of detection is higher using buffy coat isolated from a large blood volume than using whole blood for this molecular monitoring. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. On experiments to detect possible failures of relativity theory

    International Nuclear Information System (INIS)

    Rodrigues Junior, W.A.; Tiomno, J.

    1985-01-01

    Two recently proposed experiments by Kolen and Torr, designed to show failures of Einstein's Special Relativity (SR) are analysed. It is pointed out that these papers contain a number of imprecisions and misconceptions which are cleared out. Also the very spread misconception about anysotropy of propagation of light in vacuum in Lorentz Aether Theory (LAT) is analysed showing that the anysotropy is only a coordinate effect. Comparison of the correct results in LAT theory, leading to violation of SR, with new theoretical and experimental results of Torr et al is made. Some of these new results are shown to be incorrect and/or inconsistent with both SR and LAT. (Author) [pt

  10. Device for detecting imminent failure of high-dielectric stress capacitors. [Patent application

    Science.gov (United States)

    McDuff, G.G.

    1980-11-05

    A device is described for detecting imminent failure of a high-dielectric stress capacitor utilizing circuitry for detecting pulse width variations and pulse magnitude variations. Inexpensive microprocessor circuitry is utilized to make numerical calculations of digital data supplied by detection circuitry for comparison of pulse width data and magnitude data to determine if preselected ranges have been exceeded, thereby indicating imminent failure of a capacitor. Detection circuitry may be incorporated in transmission lines, pulse power circuitry, including laser pulse circuitry or any circuitry where capacitors or capacitor banks are utilized.

  11. The flaw-detected coating and its applications in R&M of aircrafts

    Science.gov (United States)

    Hu, Feng; Liu, Mabao; Lü, Zhigang

    2009-07-01

    A monitoring method called ICM (Intelligent Coating Monitoring), which is based mainly on the intelligent coating sensors, has the capability to monitor crack initiation and growth in fatigue test coupons has been suggested in this study. The intelligent coating sensor is normally consisted of three layers: driving layer, sensing layer and protective layer where necessary. Fatigue tests with ICM for various materials demonstrate the capability to detect cracks with lfuel tank of an aircraft), or (ii) to take advantage of early detection and apply less invasive life-extension repairs, as well as reduce interruption of service when flaws are detected. Implementation of ICM is expected to improve fleet management practices and modify damage tolerance assumptions.

  12. Error Detection and Error Classification: Failure Awareness in Data Transfer Scheduling

    Energy Technology Data Exchange (ETDEWEB)

    Louisiana State University; Balman, Mehmet; Kosar, Tevfik

    2010-10-27

    Data transfer in distributed environment is prone to frequent failures resulting from back-end system level problems, like connectivity failure which is technically untraceable by users. Error messages are not logged efficiently, and sometimes are not relevant/useful from users point-of-view. Our study explores the possibility of an efficient error detection and reporting system for such environments. Prior knowledge about the environment and awareness of the actual reason behind a failure would enable higher level planners to make better and accurate decisions. It is necessary to have well defined error detection and error reporting methods to increase the usability and serviceability of existing data transfer protocols and data management systems. We investigate the applicability of early error detection and error classification techniques and propose an error reporting framework and a failure-aware data transfer life cycle to improve arrangement of data transfer operations and to enhance decision making of data transfer schedulers.

  13. On-line defect detection of aluminum coating using fiber optic sensor

    Science.gov (United States)

    Patil, Supriya S.; Shaligram, A. D.

    2015-03-01

    Aluminum metallization using the sprayed coating for exhaust mild steel (MS) pipes of tractors is a standard practice for avoiding rusting. Patches of thin metal coats are prone to rusting and are thus considered as defects in the surface coating. This paper reports a novel configuration of the fiber optic sensor for on-line checking the aluminum metallization uniformity and hence for defect detection. An optimally chosen high bright 440 nm BLUE LED (light-emitting diode) launches light into a transmitting fiber inclined at the angle of 60° to the surface under inspection placed adequately. The reflected light is transported by a receiving fiber to a blue enhanced photo detector. The metallization thickness on the coated surface results in visually observable variation in the gray shades. The coated pipe is spirally inspected by a combination of linear and rotary motions. The sensor output is the signal conditioned and monitored with RISHUBH DAS. Experimental results show the good repeatability in the defect detection and coating non-uniformity measurement.

  14. Intuitionistic fuzzy-based model for failure detection.

    Science.gov (United States)

    Aikhuele, Daniel O; Turan, Faiz B M

    2016-01-01

    In identifying to-be-improved product component(s), the customer/user requirements which are mainly considered, and achieved through customer surveys using the quality function deployment (QFD) tool, often fail to guarantee or cover aspects of the product reliability. Even when they do, there are always many misunderstandings. To improve the product reliability and quality during product redesigning phase and to create that novel product(s) for the customers, the failure information of the existing product, and its component(s) should ordinarily be analyzed and converted to appropriate design knowledge for the design engineer. In this paper, a new intuitionistic fuzzy multi-criteria decision-making method has been proposed. The new approach which is based on an intuitionistic fuzzy TOPSIS model uses an exponential-related function for the computation of the separation measures from the intuitionistic fuzzy positive ideal solution (IFPIS) and intuitionistic fuzzy negative ideal solution (IFNIS) of alternatives. The proposed method has been applied to two practical case studies, and the result from the different cases has been compared with some similar computational approaches in the literature.

  15. Development of Uranium-Carrying Ball method for calibration of fuel element failure detecting systems

    International Nuclear Information System (INIS)

    Liu Yupu; Bao Wanping; Lu Cungang

    1988-01-01

    A Uranium-Carrying Ball method used for the determination of sensitivity, stability of the fuel element failure detecting systems is developed. A special facility for transporting the ball can be carried out by the flow of the cooling water, so that the failure signal can be simulated. Five different types of the Uranium-Carrying Ball have been developed. Type-I to Type-IV may provide failure signal in terms of uranium quantity or exposure area of uranium. Type-V can be used to simulate micro-flaw and examine the detectability of various detective methods for this kind of defect, at the same time it is difficult for the delayed neutron detector to detect micro-flaw. The results of long-time irradiation and washing test show that the working life of the balls is satisfactory. Using the experimentel facility with the balls, detailed study of the capability of various fuel failure detecting systems have been conducted successfully. The operation is easy and safe, the accuracy of this method is higher than that of other methods, the nuclear fuel consumption as well as the radioactive contamination is low. At present, the research on the failure mechanism is being conducted by means of this method

  16. Elaboration of colloidal silica sols in aqueous medium: functionalities, optical properties and chemical detection of coating

    International Nuclear Information System (INIS)

    Le Guevel, X.

    2006-03-01

    The aim of this work was to study surface reactivity of silica nanoparticles through physical and chemical properties of sols and coatings. Applications are numerous and they are illustrated in this work by optical coating preparation for laser components and chemical gas sensor development for nitroaromatics detection. On one hand, protocol synthesis of colloidal silica sols has been developed in water medium using sol-gel process (0 to 100 w%). These sols, so-called BLUESIL, are time-stable during at least one year. Homogeneous coatings having thickness fixed to 200 nm, have been prepared on silica substrate and show high porosity and high transparence. Original films have been developed using catalytic curing in gas atmosphere (ammonia curing) conferring good abrasive resistance to the coating without significant properties modification. In order to reduce film sensitivity to molecular adsorption (water, polluting agents... ), specific BLUESIL coatings have been prepared showing hydrophobic property due to apolar species grafting onto silica nanoparticles. Using this route, coatings having several functional properties such as transparence, hydrophobicity, high porosity and good abrasive resistance have been elaborated. On the other hand, we show that colloidal silica is a material specifically adapted to the detection of nitro aromatic vapors (NAC). Indeed, the use of colloidal silica as chemical gas sensor reveals very high sensitivity, selectivity to NAC compared to Volatile Organic Compound (V.O.C) and good detection performances during one year. Moreover, chemical sensors using functionalized colloidal silica have exhibited good results of detection, even in high humidity medium (≥70 %RH). (author)

  17. System of the sensor failure detection and isolation system using Kalman filter

    International Nuclear Information System (INIS)

    Assumpcao Filho, E.O.; Nakata, H.

    1991-01-01

    The present work work summarizes the development of the sensor failure detection and isolation system (FDIS) suitable to be implemented in nuclear plant control systems. The methodology is based on the extended Kalman filter applied to a PWR pressurizer simplified model. The simulation of the most representative failure types showed the great reliability and fast response capability of the FDIS developed allowing the sizable savings in computational and economic expenditures. (author)

  18. Dielectric Spectroscopic Detection of Early Failures in 3-D Integrated Circuits.

    Science.gov (United States)

    Obeng, Yaw; Okoro, C A; Ahn, Jung-Joon; You, Lin; Kopanski, Joseph J

    The commercial introduction of three dimensional integrated circuits (3D-ICs) has been hindered by reliability challenges, such as stress related failures, resistivity changes, and unexplained early failures. In this paper, we discuss a new RF-based metrology, based on dielectric spectroscopy, for detecting and characterizing electrically active defects in fully integrated 3D devices. These defects are traceable to the chemistry of the insolation dielectrics used in the through silicon via (TSV) construction. We show that these defects may be responsible for some of the unexplained early reliability failures observed in TSV enabled 3D devices.

  19. Program for generating tests for the detection of failures in combinatorial logic systems

    International Nuclear Information System (INIS)

    Mansour, Mounir

    1972-01-01

    A method for generating test sequences for detecting failures in combinatorial logic systems, is described. It relies on: the splitting of these systems into elements of NOR and NAND circuits, the propagation of the failure state from the input to the output. Test sequences generation is achieved in two steps: a first one called chaining during which are investigated the propagation paths of an input state able to show off failures, a second one called consistency during which the global state of the circuit related to this input configuration is held to the wanted state so that the propagation takes place. (author) [fr

  20. Study on visual detection method for wind turbine blade failure

    Science.gov (United States)

    Chen, Jianping; Shen, Zhenteng

    2018-02-01

    Start your abstract here…At present, the non-destructive testing methods of the wind turbine blades has fiber bragg grating, sound emission and vibration detection, but there are all kinds of defects, and the engineering application is difficult. In this regard, three-point slope deviation method, which is a kind of visual inspection method, is proposed for monitoring the running status of wind turbine blade based on the image processing technology. A better blade image can be got through calibration, image splicing, pretreatment and threshold segmentation algorithm. Design of the early warning system to monitor wind turbine blade running condition, recognition rate, stability and impact factors of the method were statistically analysed. The experimental results shown showed that it has highly accurate and good monitoring effect.

  1. Optical Fiber Nanotips Coated with Molecular Beacons for DNA Detection

    Directory of Open Access Journals (Sweden)

    Ambra Giannetti

    2015-04-01

    Full Text Available Optical fiber sensors, thanks to their compactness, fast response and real-time measurements, have a large impact in the fields of life science research, drug discovery and medical diagnostics. In recent years, advances in nanotechnology have resulted in the development of nanotools, capable of entering the single cell, resulting in new nanobiosensors useful for the detection of biomolecules inside living cells. In this paper, we provide an application of a nanotip coupled with molecular beacons (MBs for the detection of DNA. The MBs were characterized by hybridization studies with a complementary target to prove their functionality both free in solution and immobilized onto a solid support. The solid support chosen as substrate for the immobilization of the MBs was a 30 nm tapered tip of an optical fiber, fabricated by chemical etching. With this set-up promising results were obtained and a limit of detection (LOD of 0.57 nM was reached, opening up the possibility of using the proposed nanotip to detect mRNAs inside the cytoplasm of living cells.

  2. Bond Coat Engineering Influence on the Evolution of the Microstructure, Bond Strength, and Failure of TBCs Subjected to Thermal Cycling

    Science.gov (United States)

    Lima, R. S.; Nagy, D.; Marple, B. R.

    2015-01-01

    Different types of thermal spray systems, including HVOF (JP5000 and DJ2600-hybrid), APS (F4-MB and Axial III), and LPPS (Oerlikon Metco system) were employed to spray CoNiCrAlY bond coats (BCs) onto Inconel 625 substrates. The chemical composition of the BC powder was the same in all cases; however, the particle size distribution of the powder employed with each torch was that specifically recommended for the torch. For optimization purposes, these BCs were screened based on initial evaluations of roughness, porosity, residual stress, relative oxidation, and isothermal TGO growth. A single type of standard YSZ top coat was deposited via APS (F4MB) on all the optimized BCs. The TBCs were thermally cycled by employing a furnace cycle test (FCT) (1080 °C-1 h—followed by forced air cooling). Samples were submitted to 10, 100, 400, and 1400 cycles as well as being cycled to failure. The behavior of the microstructures, bond strength values (ASTM 633), and the TGO evolution of these TBCs, were investigated for the as-sprayed and thermally cycled samples. During FCT, the TBCs found to be both the best and poorest performing and had their BCs deposited via HVOF. The results showed that engineering low-oxidized BCs does not necessarily lead to an optimal TBC performance. Moreover, the bond strength values decrease significantly only when the TBC is about to fail (top coat spall off) and the as-sprayed bond strength values cannot be used as an indicator of TBC performance.

  3. Surface Coatings as Xenon Diffusion Barriers for Improved Detection of Clandestine Nuclear Explosions

    OpenAIRE

    Bläckberg, Lisa

    2014-01-01

    This thesis investigates surface coatings as xenon diffusion barriers on plastic scintillators. The motivation for the work is improved radioxenon detection systems, used within the verification regime of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). One type of radioxenon detection systems used in this context is the Swedish SAUNA system. This system uses a cylindrical plastic scintillator cell to measure the beta decay from radioxenon isotopes. The detector cell also acts as a container...

  4. Failure detection by adaptive lattice modelling using Kalman filtering methodology : application to NPP

    International Nuclear Information System (INIS)

    Ciftcioglu, O.

    1991-03-01

    Detection of failure in the operational status of a NPP is described. The method uses lattice form of the signal modelling established by means of Kalman filtering methodology. In this approach each lattice parameter is considered to be a state and the minimum variance estimate of the states is performed adaptively by optimal parameter estimation together with fast convergence and favourable statistical properties. In particular, the state covariance is also the covariance of the error committed by that estimate of the state value and the Mahalanobis distance formed for pattern comparison takes x 2 distribution for normally distributed signals. The failure detection is performed after a decision making process by probabilistic assessments based on the statistical information provided. The failure detection system is implemented in multi-channel signal environment of Borssele NPP and its favourable features are demonstrated. (author). 29 refs.; 7 figs

  5. Improvement of a method for predicting failure rates of coated particles during irradiation

    International Nuclear Information System (INIS)

    Bongartz, K.

    1977-01-01

    A method for calculating the coating stress distribution resulting from the statistical spread of geometrical parameters in irradiated fuel particle batches has been developed by Gulden et al. The existing method utilizing coated particles is extended in two ways: 1. A more realistic treatment of the buffer layer is adopted, taking into account its physical properties. 2. A statistical distribution according to Weibull has been adopted for the silicon carbide layer strength. Calculations with both the new and the old assumptions were performed on one feed particle and one breed particle type. It is shown that the two modifications influence the results of the original method. It was found that the extension of the first assumption has no influence on the stress distribution and the fraction of breaking feed particles, but it changes the stress distribution of the breed particles significantly. The fraction of broken particles at end burnup is increased by a factor of approximately 10. The extension of the second assumption affects the fraction of broken feed as well as that of the breed particles. Depending on the Weibull parameter, m, the number of failed feed particles increases by a factor of 1.3 to 2; the corresponding factor for breed particles is between 3.5 and 60

  6. Filtering technique for detection and identification of measurement failures in nuclear power plants

    International Nuclear Information System (INIS)

    Racz, A.

    1989-11-01

    The basic requirement of the safe operation of nuclear power plants (NPP) is to have reliable information on all quantities that can be measured, monitored or controlled during the operation. Kalman filtering techniques have been applied for prompt detection and identification of failures in the measurement systems used in NPPs. Mathematical basis of Kalman filtering and various models applied to failure detection are overviewed. The applicability of some models are evaluated by real results of NPP measurements. A sample system for an NPP is suggested, based on several numerical tests. (R.P.) 23 refs.; 40 figs.; 2 tabs

  7. Bearing failure detection of micro wind turbine via power spectral density analysis for stator current signals spectrum

    Science.gov (United States)

    Mahmood, Faleh H.; Kadhim, Hussein T.; Resen, Ali K.; Shaban, Auday H.

    2018-05-01

    The failure such as air gap weirdness, rubbing, and scrapping between stator and rotor generator arise unavoidably and may cause extremely terrible results for a wind turbine. Therefore, we should pay more attention to detect and identify its cause-bearing failure in wind turbine to improve the operational reliability. The current paper tends to use of power spectral density analysis method of detecting internal race and external race bearing failure in micro wind turbine by estimation stator current signal of the generator. The failure detector method shows that it is well suited and effective for bearing failure detection.

  8. Investigation on feasibility and detection limits for determination of coating film thickness by neutron activation analysis

    International Nuclear Information System (INIS)

    Yao Maoying; Xu Jiayun; Zhang Dida; Yang Zunyong; Yao Zhenqiang; Wang Mingqiu; Gao Dangzhong

    2010-01-01

    A method for the determination of coating film thickness by neutron activation was proposed in this paper. After Au, Al and Cu et al.films were activated with a Am-Be neutron source, the characteristic γ-rays emitted by the activated nuclides in the films were counted with a HPGe γ spectrometer. The detection limits of film thickness by using a nuclear reactor neutron source were deduced on the basis of the γ-ray counts and the Monte-Carlo simulated detection efficiencies. The possible detection limits are typically 4-5 orders of magnitude better than those by fluorescent X-ray method, which is currently widely used to determine coating film thickness. (authors)

  9. A study of the deformation and failure mechanisms of protective intermetallic coatings on AZ91 Mg alloys using microcantilever bending

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Mingyuan; Mead, James; Wu, Yueqin; Russell, Hugh; Huang, Han, E-mail: han.huang@uq.edu.au

    2016-10-15

    In this study, a nanoindentation-based microcantilever bending technique was utilized to investigate the interfacial properties of a β-Mg{sub 17}Al{sub 12}/AZ91 Mg alloy film/substrate system under tensile loading conditions. Finite element analysis (FEA) was first undertaken to optimise the design of cantilever structures for inducing high tensile stresses at the interface. Cantilevers consisting of a necked region or notch at the interface were determined to be the most successful designs. Microcantilevers containing the β-Mg{sub 17}Al{sub 12}/AZ91 interface were then made using focused ion beam (FIB) milling technique. Necks were made in the cantilevers to intensify the tension at the interface and notches were used to introduce a stress concentration to the interface. During bending, the cantilevers were deflected to failure. Subsequent analysis of the deformed cantilevers using electron microscopies revealed that plastic deformation, and subsequent ductile rupture, of the AZ91 phase was the dominant failure mechanism. When the β-Mg{sub 17}Al{sub 12}/AZ91 film/substrate system was subjected to tension, the softer AZ91 phase failed prior to interfacial delamination, demonstrating that the strength of the interface exceeded the stresses that caused ductile failure in the substrate material. - Highlights: •Microcantilever bending was used to study the property of film/substrate interface. •FEA was used to optimise cantilever design for achieving high interfacial tension. •The intermetallic coatings on AZ91 substrate have strong interfacial adhesion.

  10. Piezoelectric sensing coating for real time impact detection and location on aircraft structures

    International Nuclear Information System (INIS)

    Capsal, Jean-Fabien; David, Charlotte; Dantras, Eric; Lacabanne, Colette

    2012-01-01

    Flexible, light weight and low cost electroactive coating has been fabricated by the dispersion of inorganic ferroelectric submicron particles in a polyurethane matrix. BaTiO 3 particles have a mean diameter of 300 nm. The poling process and the influence of volume fraction of BaTiO 3 on the piezoelectric activity of the coating have been reported. This spray coating has been realized on 1.6 × 1.6 m 2 poly(epoxy)/carbon fiber reinforced composite. Impact detection has been also performed. A well-known cross correlated algorithm has been successfully employed to localize impact in a 90 × 90 cm 2 area of the composite. (paper)

  11. Arc-discharge system for nondestructive detection of flaws in thin ceramic coatings

    International Nuclear Information System (INIS)

    Scott, G.W.; Davis, E.V.

    1978-04-01

    The feasibility of nondestructively detecting small cracks or holes in plasma-sprayed ceramic coatings with an electric arc-discharge system was studied. We inspected ZrO 2 coatings 0.46 mm (0.018 in.) thick on Incoloy alloy 800 substrates. Cracks were artificially induced in controlled areas of the specimens by straining the substrates in tension. We designed and built a system to scan the specimen's surface at approximately 50 μm (0.002 in.) clearance with a sharp-pointed metal-tipped probe at high dc potential. The system measures the arc currents occurring at flaws, or plots a map of the scanned area showing points where the arc current exceeds a preset threshold. A theoretical model of the probe-specimen circuit shows constant dc potential to be the best choice for arc-discharge inspection of insulating coatings. Experimental observations and analysis of the data disclosed some potential for flaw description

  12. Failure Surface Analysis of Polyimide/Titanium Notched Coating Adhesion Specimens

    Energy Technology Data Exchange (ETDEWEB)

    GIUNTA,RACHEL K.; KANDER,RONALD G.

    2000-12-18

    Adhesively bonded joints of LaRC{trademark} PETI-5, a phenylethynyl-terminated polyimide, with chromic acid anodized titanium were fabricated and debonded interfacially. The adhesive-substrate failure surfaces were investigated using several surface analysis techniques. From Auger spectroscopy, field emission scanning electron microscopy, and atomic force microscopy studies, polymer appears to be penetrating the pores of the anodized substrate to a depth of approximately 100 nm. From x-ray photoelectron spectroscopy data, the polymer penetrating the pores appears to be in electrical contact with the titanium substrate, leading to differential charging. These analyses confirm that the polymer is becoming mechanically interlocked within the substrate surface.

  13. Real time failure detection in unreinforced cementitious composites with triboluminescent sensor

    International Nuclear Information System (INIS)

    Olawale, David O.; Kliewer, Kaitlyn; Okoye, Annuli; Dickens, Tarik J.; Uddin, Mohammed J.; Okoli, Okenwa I.

    2014-01-01

    The in-situ triboluminescent optical fiber (ITOF) sensor has an integrated sensing and transmission component that converts the energy from damage events like impacts and crack propagation into optical signals that are indicative of the magnitude of damage in composite structures like concrete bridges. Utilizing the triboluminescence (TL) property of ZnS:Mn, the ITOF sensor has been successfully integrated into unreinforced cementitious composite beams to create multifunctional smart structures with in-situ failure detection capabilities. The fabricated beams were tested under flexural loading, and real time failure detection was made by monitoring the TL signals generated by the integrated ITOF sensor. Tested beam samples emitted distinctive TL signals at the instance of failure. In addition, we report herein a new and promising approach to damage characterization using TL emission profiles. Analysis of TL emission profiles indicates that the ITOF sensor responds to crack propagation through the beam even when not in contact with the crack. Scanning electron microscopy analysis indicated that fracto-triboluminescence was responsible for the TL signals observed at the instance of beam failure. -- Highlights: • Developed a new approach to triboluminescence (TL)-based sensing with ZnS:Mn. • Damage-induced excitation of ZnS:Mn enabled real time damage detection in composite. • Based on sensor position, correlation exists between TL signal and failure stress. • Introduced a new approach to damage characterization with TL profile analysis

  14. Aircraft control surface failure detection and isolation using the OSGLR test. [orthogonal series generalized likelihood ratio

    Science.gov (United States)

    Bonnice, W. F.; Motyka, P.; Wagner, E.; Hall, S. R.

    1986-01-01

    The performance of the orthogonal series generalized likelihood ratio (OSGLR) test in detecting and isolating commercial aircraft control surface and actuator failures is evaluated. A modification to incorporate age-weighting which significantly reduces the sensitivity of the algorithm to modeling errors is presented. The steady-state implementation of the algorithm based on a single linear model valid for a cruise flight condition is tested using a nonlinear aircraft simulation. A number of off-nominal no-failure flight conditions including maneuvers, nonzero flap deflections, different turbulence levels and steady winds were tested. Based on the no-failure decision functions produced by off-nominal flight conditions, the failure detection and isolation performance at the nominal flight condition was determined. The extension of the algorithm to a wider flight envelope by scheduling on dynamic pressure and flap deflection is examined. Based on this testing, the OSGLR algorithm should be capable of detecting control surface failures that would affect the safe operation of a commercial aircraft. Isolation may be difficult if there are several surfaces which produce similar effects on the aircraft. Extending the algorithm over the entire operating envelope of a commercial aircraft appears feasible.

  15. Graphene coating for anti-corrosion and the investigation of failure mechanism

    International Nuclear Information System (INIS)

    Zhu, Y X; Duan, C Y; Chen, Y F; Wang, Y; Liu, H Y

    2017-01-01

    Graphene produced by chemical vapor deposition (CVD) methods has been considered as a promising corrosion prevention layer because of its exceptional structure and impermeability. However, the anti-corrosion performance and the failure mechanism are still controversial. In this study, graphene layers with different quality levels, crystallite sizes, and layer numbers were prepared on the surface of Cu by a CVD process. The effects of grain boundaries (GBs) on the failure of graphene layers to provide adequate protection were investigated in detail by combining graphene transfer techniques, computation, and anti-corrosion measurements. Our results reveal that corrosion rates decrease marginally upon the increase of graphene layer number, and this rather weak dependence on thickness likely arises from the aligned nature of the GBs in CVD-grown few-layer graphene. This problem can potentially be overcome by layer-by-layer graphene transfer technique, in which corrosion is found to be arrested locally when transferred graphene is present on top of the as-grown graphene. However, this advantage is not reflected in corrosion studies performed on large-scale samples, where cracks or imperfect interfaces could offset the advantages of GB misalignment. With improvements in technology, the layer-by-layer assembly technique could be used to develop an effective anti-corrosion barrier. (paper)

  16. Early Detection of Plant Equipment Failures: A Case Study in Just-in-Time Maintenance

    International Nuclear Information System (INIS)

    Parlos, Alexander G.; Kim, Kyusung; Bharadwaj, Raj M.

    2001-01-01

    The development and testing of a model-based fault detection system for electric motors is briefly presented. The fault detection system was developed using only motor nameplate information. The fault detection results presented utilize only motor voltage and current sensor information, minimizing the need for expensive or intrusive sensors. Dynamic recurrent neural networks are used to predict the input-output response of a three-phase induction motor while using an estimate of the motor speed signal. Multiresolution (or wavelet) signal-processing techniques are used in combination with more traditional methods to estimate fault features for use in winding insulation and motor mechanical and electromechanical failure detection

  17. Early Detection of Plant Equipment Failures: A Case Study in Just-in-Time Maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Parlos, Alexander G.; Kim, Kyusung; Bharadwaj, Raj M.

    2001-06-17

    The development and testing of a model-based fault detection system for electric motors is briefly presented. The fault detection system was developed using only motor nameplate information. The fault detection results presented utilize only motor voltage and current sensor information, minimizing the need for expensive or intrusive sensors. Dynamic recurrent neural networks are used to predict the input-output response of a three-phase induction motor while using an estimate of the motor speed signal. Multiresolution (or wavelet) signal-processing techniques are used in combination with more traditional methods to estimate fault features for use in winding insulation and motor mechanical and electromechanical failure detection.

  18. Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure.

    Science.gov (United States)

    Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A

    2006-02-01

    Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.

  19. Fault Detection and Location of IGBT Short-Circuit Failure in Modular Multilevel Converters

    Directory of Open Access Journals (Sweden)

    Bin Jiang

    2018-06-01

    Full Text Available A single fault detection and location for Modular Multilevel Converter (MMC is of great significance, as numbers of sub-modules (SMs in MMC are connected in series. In this paper, a novel fault detection and location method is proposed for MMC in terms of the Insulated Gate Bipolar Translator (IGBT short-circuit failure in SM. The characteristics of IGBT short-circuit failures are analyzed, based on which a Differential Comparison Low-Voltage Detection Method (DCLVDM is proposed to detect the short-circuit fault. Lastly, the faulty IGBT is located based on the capacitor voltage of the faulty SM by Continuous Wavelet Transform (CWT. Simulations have been done in the simulation software PSCAD/EMTDC and the results confirm the validity and reliability of the proposed method.

  20. Immunity-based detection, identification, and evaluation of aircraft sub-system failures

    Science.gov (United States)

    Moncayo, Hever Y.

    This thesis describes the design, development, and flight-simulation testing of an integrated Artificial Immune System (AIS) for detection, identification, and evaluation of a wide variety of sensor, actuator, propulsion, and structural failures/damages including the prediction of the achievable states and other limitations on performance and handling qualities. The AIS scheme achieves high detection rate and low number of false alarms for all the failure categories considered. Data collected using a motion-based flight simulator are used to define the self for an extended sub-region of the flight envelope. The NASA IFCS F-15 research aircraft model is used and represents a supersonic fighter which include model following adaptive control laws based on non-linear dynamic inversion and artificial neural network augmentation. The flight simulation tests are designed to analyze and demonstrate the performance of the immunity-based aircraft failure detection, identification and evaluation (FDIE) scheme. A general robustness analysis is also presented by determining the achievable limits for a desired performance in the presence of atmospheric perturbations. For the purpose of this work, the integrated AIS scheme is implemented based on three main components. The first component performs the detection when one of the considered failures is present in the system. The second component consists in the identification of the failure category and the classification according to the failed element. During the third phase a general evaluation of the failure is performed with the estimation of the magnitude/severity of the failure and the prediction of its effect on reducing the flight envelope of the aircraft system. Solutions and alternatives to specific design issues of the AIS scheme, such as data clustering and empty space optimization, data fusion and duplication removal, definition of features, dimensionality reduction, and selection of cluster/detector shape are also

  1. The detection of HBV DNA with gold-coated iron oxide nanoparticle gene probes

    International Nuclear Information System (INIS)

    Xi Dong; Luo Xiaoping; Lu Qianghua; Yao Kailun; Liu Zuli; Ning Qin

    2008-01-01

    Gold-coated iron oxide nanoparticle Hepatitis B virus (HBV) DNA probes were prepared, and their application for HBV DNA measurement was studied. Gold-coated iron oxide nanoparticles were prepared by the citrate reduction of tetra-chloroauric acid in the presence of iron oxide nanoparticles which were added as seeds. With a fluorescence-based method, the maximal surface coverage of hexaethiol 30-mer oligonucleotides and the maximal percentage of hybridization strands on gold-coated iron oxide nanoparticles were (120 ± 8) oligonucleotides per nanoparticle, and (14 ± 2%), respectively, which were comparable with those of (132 ± 10) and (22 ± 3%) in Au nanoparticle groups. Large network aggregates were formed when gold-coated iron oxide nanoparticle HBV DNA gene probe was applied to detect HBV DNA molecules as evidenced by transmission electron microscopy and the high specificity was verified by blot hybridization. Our results further suggested that detecting DNA with iron oxide nanoparticles and magnetic separator was feasible and might be an alternative effective method

  2. Probability of failure of the watershed algorithm for peak detection in comprehensive two-dimensional chromatography

    NARCIS (Netherlands)

    Vivó-Truyols, G.; Janssen, H.-G.

    2010-01-01

    The watershed algorithm is the most common method used for peak detection and integration In two-dimensional chromatography However, the retention time variability in the second dimension may render the algorithm to fail A study calculating the probabilities of failure of the watershed algorithm was

  3. Enhanced dopamine detection sensitivity by PEDOT/graphene oxide coating on in vivo carbon fiber electrodes.

    Science.gov (United States)

    Taylor, I Mitch; Robbins, Elaine M; Catt, Kasey A; Cody, Patrick A; Happe, Cassandra L; Cui, Xinyan Tracy

    2017-03-15

    Dopamine (DA) is a monoamine neurotransmitter responsible for regulating a variety of vital life functions. In vivo detection of DA poses a challenge due to the low concentration and high speed of physiological signaling. Fast scan cyclic voltammetry at carbon fiber microelectrodes (CFEs) is an effective method to monitor real-time in vivo DA signaling, however the sensitivity is somewhat limited. Electrodeposition of poly(3,4-ethylene dioxythiophene) (PEDOT)/graphene oxide (GO) onto the CFE surface is shown to increase the sensitivity and lower the limit of detection for DA compared to bare CFEs. Thicker PEDOT/GO coatings demonstrate higher sensitivities for DA, but display the negative drawback of slow adsorption and electron transfer kinetics. The moderate thickness resulting from 25 s electrodeposition of PEDOT/GO produces the optimal electrode, exhibiting an 880% increase in sensitivity, a 50% decrease in limit of detection and minimally altered electrode kinetics. PEDOT/GO coated electrodes rapidly and robustly detect DA, both in solution and in the rat dorsal striatum. This increase in DA sensitivity is likely due to increasing the electrode surface area with a PEDOT/GO coating and improved adsorption of DA's oxidation product (DA-o-quinone). Increasing DA sensitivity without compromising electrode kinetics is expected to significantly improve our understanding of the DA function in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Deep learning of contrast-coated serrated polyps for computer-aided detection in CT colonography

    Science.gov (United States)

    Näppi, Janne J.; Pickhardt, Perry; Kim, David H.; Hironaka, Toru; Yoshida, Hiroyuki

    2017-03-01

    Serrated polyps were previously believed to be benign lesions with no cancer potential. However, recent studies have revealed a novel molecular pathway where also serrated polyps can develop into colorectal cancer. CT colonography (CTC) can detect serrated polyps using the radiomic biomarker of contrast coating, but this requires expertise from the reader and current computer-aided detection (CADe) systems have not been designed to detect the contrast coating. The purpose of this study was to develop a novel CADe method that makes use of deep learning to detect serrated polyps based on their contrast-coating biomarker in CTC. In the method, volumetric shape-based features are used to detect polyp sites over soft-tissue and fecal-tagging surfaces of the colon. The detected sites are imaged using multi-angular 2D image patches. A deep convolutional neural network (DCNN) is used to review the image patches for the presence of polyps. The DCNN-based polyp-likelihood estimates are merged into an aggregate likelihood index where highest values indicate the presence of a polyp. For pilot evaluation, the proposed DCNN-CADe method was evaluated with a 10-fold cross-validation scheme using 101 colonoscopy-confirmed cases with 144 biopsy-confirmed serrated polyps from a CTC screening program, where the patients had been prepared for CTC with saline laxative and fecal tagging by barium and iodine-based diatrizoate. The average per-polyp sensitivity for serrated polyps >=6 mm in size was 93+/-7% at 0:8+/-1:8 false positives per patient on average. The detection accuracy was substantially higher that of a conventional CADe system. Our results indicate that serrated polyps can be detected automatically at high accuracy in CTC.

  5. Effect of Hemodialysis on Eye Coats, Axial Length, and Ocular Perfusion Pressure in Patients with Chronic Renal Failure

    Directory of Open Access Journals (Sweden)

    Ling Wang

    2018-01-01

    Full Text Available Purpose. To investigate changes in eye coats, axial length, and ocular perfusion pressure (OPP in hemodialysis (HD patients with chronic renal failure (CRF. Methods. We included HD patients who were diagnosed with CRF in our hospital from January to December 2015. Fifty-two patients met the inclusion criteria; all right eyes were used for observation. Systolic and diastolic blood pressures were recorded to calculate OPP. Approximately 30 minutes before and after HD, we recorded multiple parameters, including lens thickness (LT, axial length of vitreous (VAL, axial length of eye (EAL, ciliary body thickness (CBT, choroidal thickness (CT, and retinal thickness (RT. Results. After HD, OPP significantly decreased (P<0.01, F=7.023 and CBT became significantly thinner (P<0.01, t=3.461. CT was significantly thinner and differed among measurement locations (P<0.01, t=6.240; P<0.01, t=6.169; P<0.01, t=3.405, respectively, fovea, nasal, and temporal side 1500 μm beside the fovea. Further, RT thickened and differed among measurement locations (P<0.05, t=−2.265; P<0.05, t=−2.624; P<0.05, t=−2.220, respectively, fovea, nasal, and temporal side 1500 μm beside fovea, whereas LT, VAL, and EAL significantly increased after HD (P<0.05, t=−2.076; P<0.01, t=−3.817; P<0.01, t=−4.010. Conclusions. HD impacts the thickness of the eye coats and VAL, particularly affecting CBT, CT, and RT. OPP transiently decreases during HD, which may contribute to an ischemic state.

  6. Performance and sensitivity analysis of the generalized likelihood ratio method for failure detection. M.S. Thesis

    Science.gov (United States)

    Bueno, R. A.

    1977-01-01

    Results of the generalized likelihood ratio (GLR) technique for the detection of failures in aircraft application are presented, and its relationship to the properties of the Kalman-Bucy filter is examined. Under the assumption that the system is perfectly modeled, the detectability and distinguishability of four failure types are investigated by means of analysis and simulations. Detection of failures is found satisfactory, but problems in identifying correctly the mode of a failure may arise. These issues are closely examined as well as the sensitivity of GLR to modeling errors. The advantages and disadvantages of this technique are discussed, and various modifications are suggested to reduce its limitations in performance and computational complexity.

  7. Fission product release modelling for application of fuel-failure monitoring and detection - An overview

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, B.J., E-mail: lewibre@gmail.com [Department of Chemistry and Chemical Engineering, Royal Military College of Canada, Kingston, Ontario, K7K 7B4 (Canada); Chan, P.K.; El-Jaby, A. [Department of Chemistry and Chemical Engineering, Royal Military College of Canada, Kingston, Ontario, K7K 7B4 (Canada); Iglesias, F.C.; Fitchett, A. [Candesco Division of Kinectrics Inc., 26 Wellington Street East, 3rd Floor, Toronto, Ontario M5E 1S2 (Canada)

    2017-06-15

    A review of fission product release theory is presented in support of fuel-failure monitoring analysis for the characterization and location of defective fuel. This work is used to describe: (i) the development of the steady-state Visual-DETECT code for coolant activity analysis to characterize failures in the core and the amount of tramp uranium; (ii) a generalization of this model in the STAR code for prediction of the time-dependent release of iodine and noble gas fission products to the coolant during reactor start-up, steady-state, shutdown, and bundle-shifting manoeuvres; (iii) an extension of the model to account for the release of fission products that are delayed-neutron precursors for assessment of fuel-failure location; and (iv) a simplification of the steady-state model to assess the methodology proposed by WANO for a fuel reliability indicator for water-cooled reactors.

  8. Clinical significance of detection of plasma natriuretic peptide in the diagnosis of patients with heart failure

    International Nuclear Information System (INIS)

    Song Chunli; Liu Haihong; Zhao Ning; Li Jie; Huang Jianmin

    2009-01-01

    To explore the clinical significance of plasma natriuretic peptide in the diagnosis of patients with heart failure (HF), the plasma atrial natriuretic peptide (ANP), brain natriuretic peptide (BNP), NT-pro brain natriuretic peptide (NT-proBNP) levels in 129 patients with heart failure and 30 healthy controls were detected by RIA and ELISA. The results showed that the plasma ANP, BNP, NT-proBNP levels in patients with heart failure were significantly higher than the healthy controls. As the cardiac function deteriorated from NYHA I to IV, the BNP and NT-proBNP levels increased consecutively with significant differences from each other. There was a negative correlation between the plasma ANP and NT-proBNP levels and LVEF. The determination of plasma ANP, BNP and NT-proBNP levels in patients with HF were helpful to the study of the severity and diagnosis of disease. (authors)

  9. Using pattern analysis methods to do fast detection of manufacturing pattern failures

    Science.gov (United States)

    Zhao, Evan; Wang, Jessie; Sun, Mason; Wang, Jeff; Zhang, Yifan; Sweis, Jason; Lai, Ya-Chieh; Ding, Hua

    2016-03-01

    At the advanced technology node, logic design has become extremely complex and is getting more challenging as the pattern geometry size decreases. The small sizes of layout patterns are becoming very sensitive to process variations. Meanwhile, the high pressure of yield ramp is always there due to time-to-market competition. The company that achieves patterning maturity earlier than others will have a great advantage and a better chance to realize maximum profit margins. For debugging silicon failures, DFT diagnostics can identify which nets or cells caused the yield loss. But normally, a long time period is needed with many resources to identify which failures are due to one common layout pattern or structure. This paper will present a new yield diagnostic flow, based on preliminary EFA results, to show how pattern analysis can more efficiently detect pattern related systematic defects. Increased visibility on design pattern related failures also allows more precise yield loss estimation.

  10. Design of the scanning mode coated glass color difference online detection system

    Science.gov (United States)

    Bi, Weihong; Zhang, Yu; Wang, Dajiang; Zhang, Baojun; Fu, Guangwei

    2008-03-01

    A design of scanning mode coated glass color difference online detection system was introduced. The system consisted of color difference data acquirement part and orbit control part. The function of the color difference data acquirement part was to acquire glass spectral reflectance and then processed them to get the color difference value. Using fiber for light guiding, the reflected light from surface of glass was transmitted into light division part, and the dispersive light was imaged on linear CCD, and then the output signals from the CCD was sampled pixel by pixel, and the spectral reflectance of coated glass was obtained finally. Then, the acquired spectral reflectance signals was sent to industrial personal computer through USB interface, using standard color space and color difference formula nominated by International Commission on Illumination (CIE) in 1976 to process these signals, and the reflected color parameter and color difference of coated glass was gained in the end. The function of the orbit control part was to move the detection probe by way of transverse scanning mode above the glass strip, and control the measuring start-stop time of the color difference data acquirement part at the same time. The color difference data acquirement part of the system was put on the orbit which is after annealing area in coated glass production line, and the protected fiber probe was placed on slide of the orbit. Using single chip microcomputer to control transmission mechanism of the slide, which made the slide move by way of transverse scanning mode on the glass strip, meanwhile, the color difference data acquirement part of the system was also controlled by the single chip microcomputer, and it made the acquirement part measure color difference data when the probe reached the needed working speed and required place on the glass strip. The scanning mode coated glass color difference online detection system can measure color parameter and color difference of

  11. A new method for detecting pressure tube failures in Indian PHWRs

    International Nuclear Information System (INIS)

    Sharma, V.K.; Gupta, V.K.

    2000-01-01

    For the annulus gas system (AGS) of the standardised Indian pressurised heavy water reactor, an elaborate pressure tube (PT) crack monitoring and detection system is envisaged to ensure safety through leak-before-break. The parameters that are monitored relate to the detection of D 2 O moisture leaking in from the primary heat transport (PHT) system through a cracked PT. Since a slow build-up of moisture in the AGS may also occur for reasons other than PT failure, it is desirable that a diverse measurement technique should be available. This paper suggests such a technique, based on the observation that a small reference concentration of fission gases is normally present in the annulus gas. This concentration would change sharply upon PT failure, when the heavy water from the leaking PHT system releases the dissolved fission gas content into the annulus. This paper presents a theoretical study of the parameters that influence the build-up of fission product noble gases in the AGS and shows that leakage rates as low as 10 g h -1 from a PT crack can be detected in a few tens of minutes by this method. This is expected to substantially increase the available time between the leak detection and the PT failure, thus serving as an important tool in meeting the leak-before-break criterion of a critical component in PHWRs. (orig.)

  12. Near-field microwave detection of corrosion precursor pitting under thin dielectric coatings in metallic substrate

    International Nuclear Information System (INIS)

    Hughes, D.; Zoughi, R.; Austin, R.; Wood, N.; Engelbart, R.

    2003-01-01

    Detection of corrosion precursor pitting on metallic surfaces under various coatings and on bare metal is of keen interest in evaluation of aircraft fuselage. Near-field microwave nondestructive testing methods, utilizing open-ended rectangular waveguides and coaxial probes, have been used extensively for detection of surface flaws in metals, both on bare metal and under a dielectric coating. This paper presents the preliminary results of using microwave techniques to detect corrosion precursor pitting under paint and primer, applique and on bare metal. Machined pits of 500 μm diameter were detected using open-ended rectangular waveguides at V-Band under paint and primer and applique, and on bare metal. Using coaxial probes, machined pits with diameters down to 150 μm on bare metal were also detected. Relative pit size and density were shown on a corrosion-pitted sample using open-ended rectangular waveguides at frequencies of 35 GHz to 70 GHz. The use of Boeing's MAUS TM scanning systems provided improved results by alleviating standoff variation and scanning artifact. Typical results of this investigation are also presented

  13. Colorimetric detection of trace copper ions based on catalytic leaching of silver-coated gold nanoparticles.

    Science.gov (United States)

    Lou, Tingting; Chen, Lingxin; Chen, Zhaopeng; Wang, Yunqing; Chen, Ling; Li, Jinhua

    2011-11-01

    A colorimetric, label-free, and nonaggregation-based silver coated gold nanoparticles (Ag/Au NPs) probe has been developed for detection of trace Cu(2+) in aqueous solution, based on the fact that Cu(2+) can accelerate the leaching rate of Ag/Au NPs by thiosulfate (S(2)O(3)(2-)). The leaching of Ag/Au NPs would lead to dramatic decrease in the surface plasmon resonance (SPR) absorption as the size of Ag/Au NPs decreased. This colorimetric strategy based on size-dependence of nanoparticles during their leaching process provided a highly sensitive (1.0 nM) and selective detection toward Cu(2+), with a wide linear detection range (5-800 nM) over nearly 3 orders of magnitude. The cost-effective probe allows rapid and sensitive detection of trace Cu(2+) ions in water samples, indicating its potential applicability for the determination of copper in real samples.

  14. Damage and failure detection of composites using optical fiber vibration sensor

    International Nuclear Information System (INIS)

    Yang, Y. C.; Han, K. S.

    2001-01-01

    An intensity-based optical fiber vibration sensor is applied to detect and evaluate damages and fiber failure of composites. The optical fiber vibration sensor is constructed by placing two cleaved fiber end, one of which is cantilevered in a hollow glass tube. The movement of the cantilevered section lags behind the rest of the sensor in response to an applied vibration and the amount of light coupled between the two fibers is thereby modulated. Vibration characteristics of the optical fiber vibration sensor are investigated. Surface mounted optical fiber vibration sensor is used in tensile and indentation test. Experimental results show that the optical fiber sensor can detect damages and fiber failure of composites correctly

  15. Skin-Spar Failure Detection of a Composite Winglet Using FBG Sensors

    Directory of Open Access Journals (Sweden)

    Ciminello Monica

    2017-09-01

    Full Text Available Winglets are introduced into modern aircraft to reduce wing aerodynamic drag and to consequently optimize the fuel burn per mission. In order to be aerodynamically effective, these devices are installed at the wing tip section; this wing region is generally characterized by relevant oscillations induced by flights maneuvers and gust. The present work is focused on the validation of a continuous monitoring system based on fiber Bragg grating sensors and frequency domain analysis to detect physical condition of a skin-spar bonding failure in a composite winglet for in-service purposes. Optical fibers are used as deformation sensors. Short Time Fast Fourier Transform (STFT analysis is applied to analyze the occurrence of structural response deviations on the base of strain data. Obtained results showed high accuracy in estimating static and dynamic deformations and great potentials in detecting structural failure occurrences.

  16. Real-time sensor failure detection by dynamic modelling of a PWR plant

    International Nuclear Information System (INIS)

    Turkcan, E.; Ciftcioglu, O.

    1992-06-01

    Signal validation and sensor failure detection is an important problem in real-time nuclear power plant (NPP) surveillance. Although conventional sensor redundancy, in a way, is a solution, identification of faulty sensor is necessary for further preventive actions to be taken. A comprehensive solution for the system so that any sensory reading is verified by its model based estimated counterpart, in real-time. Such a realization is accomplished by means of dynamic system's states estimation methodology using Kalman filter modelling technique. The method is investigated by means of real-time data of the steam generator of Borssele nuclear power plant and the method has proved to be satisfactory for real-time sensor failure detection as well as model validation verification. (author). 5 refs.; 6 figs.; 1 tab

  17. Evaluation of a Kalman filter based power pressurizer instrument failure detection system implemented on a nuclear power plant training simulator

    International Nuclear Information System (INIS)

    Seegmiller, D.S.

    1984-01-01

    The usefulness of a nuclear power plant training simulator for developing and testing modern estimation and control applications for nuclear power plants is demonstrated. A Kalman filter based instrument failure detection technique for a pressurized water reactor pressurizer is implemented on the Department of Energy N Reactor Training Simulator. This real-time failure detection method computes the first two moments (mean and variance) of each element of a normalized filter innovations vector. Failed pressurizer instrumentation can be detected by comparing these moments to the known statistical properties of the steady state, linear Kalman fitler innovations sequence. The capabilities of the detection system are evaluated using simulated plant transients and instrument failures

  18. Lab Coats or Trench Coats? Detective Sleuthing as an Alternative to Scientifically Based Research in Indigenous Educational Communities

    Science.gov (United States)

    Kaomea, Julie

    2013-01-01

    Amidst late 19th-century efforts to emphasize modern medicine's transition to a more scientific approach, physicians seeking to represent themselves as scientists began wearing white laboratory coats. Today educational researchers are likewise urged to don metaphorical white coats as scientifically based research is held up as the cure-all for our…

  19. Unavailability of repairable components with failures detectable upon demand: Remarks on a work of Caldarola

    International Nuclear Information System (INIS)

    Souza Borges, W. de; Silva Pagetti, P. da

    1987-01-01

    In this paper an exact expression has been obtained for the asymptotic mean unavailability in time domain of components with failures detected upon demand. The model is more general than those proposed in the literature since it allows the use of general distributions for component life times, repair times and inter-demand times. Expressions for the special case of exponential life times have also been derived. (orig.)

  20. Real-time instrument-failure detection in the LOFT pressurizer using functional redundancy

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-07-01

    The functional redundancy approach to detecting instrument failures in a pressurized water reactor (PWR) pressurizer is described and evaluated. This real-time method uses a bank of Kalman filters (one for each instrument) to generate optimal estimates of the pressurizer state. By performing consistency checks between the output of each filter, failed instruments can be identified. Simulation results and actual pressurizer data are used to demonstrate the capabilities of the technique

  1. Chitosan coated carbon fiber microelectrode for selective in vivo detection of neurotransmitters in live zebrafish embryos

    International Nuclear Information System (INIS)

    Ozel, Rifat Emrah; Wallace, Kenneth N.; Andreescu, Silvana

    2011-01-01

    Graphical abstract: Chitosan coated fiber electrodes are sensitive to serotonin detection while rejecting physiological levels of ascorbic acid interferences. - Abstract: We report the development of a chitosan modified carbon fiber microelectrode for in vivo detection of serotonin. We find that chitosan has the ability to reject physiological levels of ascorbic acid interferences and facilitate selective and sensitive detection of in vivo levels of serotonin, a common catecholamine neurotransmitter. Presence of chitosan on the microelectrode surface was investigated using scanning electron microscopy (SEM) and cyclic voltammetry (CV). The electrode was characterized using differential pulse voltammetry (DPV). A detection limit of 1.6 nM serotonin with a sensitivity of 5.12 nA/μM, a linear range from 2 to 100 nM and a reproducibility of 6.5% for n = 6 electrodes were obtained. Chitosan modified microelectrodes selectively measure serotonin in presence of physiological levels of ascorbic acid. In vivo measurements were performed to measure concentration of serotonin in the live embryonic zebrafish intestine. The sensor quantifies in vivo intestinal levels of serotonin while successfully rejecting ascorbic acid interferences. We demonstrate that chitosan can be used as an effective coating to reject ascorbic acid interferences at carbon fiber microelectrodes, as an alternative to Nafion, and that chitosan modified microelectrodes are reliable tools for in vivo monitoring of changes in neurotransmitter levels.

  2. Hybridization chain reaction amplification for highly sensitive fluorescence detection of DNA with dextran coated microarrays.

    Science.gov (United States)

    Chao, Jie; Li, Zhenhua; Li, Jing; Peng, Hongzhen; Su, Shao; Li, Qian; Zhu, Changfeng; Zuo, Xiaolei; Song, Shiping; Wang, Lianhui; Wang, Lihua

    2016-07-15

    Microarrays of biomolecules hold great promise in the fields of genomics, proteomics, and clinical assays on account of their remarkably parallel and high-throughput assay capability. However, the fluorescence detection used in most conventional DNA microarrays is still limited by sensitivity. In this study, we have demonstrated a novel universal and highly sensitive platform for fluorescent detection of sequence specific DNA at the femtomolar level by combining dextran-coated microarrays with hybridization chain reaction (HCR) signal amplification. Three-dimensional dextran matrix was covalently coated on glass surface as the scaffold to immobilize DNA recognition probes to increase the surface binding capacity and accessibility. DNA nanowire tentacles were formed on the matrix surface for efficient signal amplification by capturing multiple fluorescent molecules in a highly ordered way. By quantifying microscopic fluorescent signals, the synergetic effects of dextran and HCR greatly improved sensitivity of DNA microarrays, with a detection limit of 10fM (1×10(5) molecules). This detection assay could recognize one-base mismatch with fluorescence signals dropped down to ~20%. This cost-effective microarray platform also worked well with samples in serum and thus shows great potential for clinical diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Chitosan coated carbon fiber microelectrode for selective in vivo detection of neurotransmitters in live zebrafish embryos

    Energy Technology Data Exchange (ETDEWEB)

    Ozel, Rifat Emrah [Department of Chemistry and Biomolecular Science, 8 Clarkson Ave, Potsdam, NY 136995810 (United States); Wallace, Kenneth N. [Department of Biology, Clarkson University, Potsdam, NY 136995810 (United States); Andreescu, Silvana, E-mail: eandrees@clarkson.edu [Department of Chemistry and Biomolecular Science, 8 Clarkson Ave, Potsdam, NY 136995810 (United States)

    2011-06-10

    Graphical abstract: Chitosan coated fiber electrodes are sensitive to serotonin detection while rejecting physiological levels of ascorbic acid interferences. - Abstract: We report the development of a chitosan modified carbon fiber microelectrode for in vivo detection of serotonin. We find that chitosan has the ability to reject physiological levels of ascorbic acid interferences and facilitate selective and sensitive detection of in vivo levels of serotonin, a common catecholamine neurotransmitter. Presence of chitosan on the microelectrode surface was investigated using scanning electron microscopy (SEM) and cyclic voltammetry (CV). The electrode was characterized using differential pulse voltammetry (DPV). A detection limit of 1.6 nM serotonin with a sensitivity of 5.12 nA/{mu}M, a linear range from 2 to 100 nM and a reproducibility of 6.5% for n = 6 electrodes were obtained. Chitosan modified microelectrodes selectively measure serotonin in presence of physiological levels of ascorbic acid. In vivo measurements were performed to measure concentration of serotonin in the live embryonic zebrafish intestine. The sensor quantifies in vivo intestinal levels of serotonin while successfully rejecting ascorbic acid interferences. We demonstrate that chitosan can be used as an effective coating to reject ascorbic acid interferences at carbon fiber microelectrodes, as an alternative to Nafion, and that chitosan modified microelectrodes are reliable tools for in vivo monitoring of changes in neurotransmitter levels.

  4. Nonparametric method for failures detection and localization in the actuating subsystem of aircraft control system

    Science.gov (United States)

    Karpenko, S. S.; Zybin, E. Yu; Kosyanchuk, V. V.

    2018-02-01

    In this paper we design a nonparametric method for failures detection and localization in the aircraft control system that uses the measurements of the control signals and the aircraft states only. It doesn’t require a priori information of the aircraft model parameters, training or statistical calculations, and is based on algebraic solvability conditions for the aircraft model identification problem. This makes it possible to significantly increase the efficiency of detection and localization problem solution by completely eliminating errors, associated with aircraft model uncertainties.

  5. The Effects of Oxidation-Induced Failures on Thermal Barrier Coatings with Platinum Aluminide and NiCoCrAlY Bond Coats

    National Research Council Canada - National Science Library

    Yanar, N

    2001-01-01

    ...) deposited via electron beam vapor deposition (EBPVD). This TBC was deposited on both platinum aluminide and NiCoCrA1Y bond coats which in turn were deposited on superalloy substrates of Rare N5...

  6. Side-detecting optical fiber coated with Zn(OH)2 nanorods for ultraviolet sensing applications

    Science.gov (United States)

    Azad, S.; Parvizi, R.; Sadeghi, E.

    2017-09-01

    This paper presents an improved coupling efficiency and side detecting of UV radiation induced by light scattering and luminescent features of Zn(OH)2 nanorods coated multimode optical fibers. Uniform and high density Zn(OH)2 nanorods were grown hydrothermally on the core of chemically etched multimode optical fibers. The prepared samples were characterized through x-ray diffraction patterns, scanning electron microscopy and photoluminescence spectroscopy. The detecting technique was based on the intensity modulation of the side coupled light through the Zn(OH)2 nanorods. A simple and cost-effective UV radiation detecting setup has been designed. Experimentally estimated coupling efficiency of the proposed setup was obtained near 11%. The proposed device exhibited stable and reversible responses with a fast rising and decaying time of about 1.4 s and 0.85 s, respectively.

  7. [Early detection, prevention and management of renal failure in liver transplantation].

    Science.gov (United States)

    Castells, Lluís; Baliellas, Carme; Bilbao, Itxarone; Cantarell, Carme; Cruzado, Josep Maria; Esforzado, Núria; García-Valdecasas, Juan Carlos; Lladó, Laura; Rimola, Antoni; Serón, Daniel; Oppenheimer, Federico

    2014-10-01

    Renal failure is a frequent complication in liver transplant recipients and is associated with increased morbidity and mortality. A variety of risk factors for the development of renal failure in the pre- and post-transplantation periods have been described, as well as at the time of surgery. To reduce the negative impact of renal failure in this population, an active approach is required for the identification of those patients with risk factors, the implementation of preventive strategies, and the early detection of progressive deterioration of renal function. Based on published evidence and on clinical experience, this document presents a series of recommendations on monitoring RF in LT recipients, as well as on the prevention and management of acute and chronic renal failure after LT and referral of these patients to the nephrologist. In addition, this document also provides an update of the various immunosuppressive regimens tested in this population for the prevention and control of post-transplantation deterioration of renal function. Copyright © 2013 Elsevier España, S.L.U. and AEEH y AEG. All rights reserved.

  8. Validation of pre-coated ELISA tests to detect antibodies against T. congolense and T. vivax

    International Nuclear Information System (INIS)

    Shumba, W.

    2000-01-01

    The anti-trypanosomal antibody detecting enzyme linked immunosorbent assay (ELISA) was first described in 1977 and was further developed for use in large scale surveys in Zimbabwe. More recently, the IAEA initiated a programme to improve the robustness and standardisation of the assay. The IAEA supplied plates pre-coated with either a crude T. congolense or T. vivax antigen and the reagents necessary for analysing samples. Parasitologically positive and negative sera were used to validate and determine the cut-off values of the two tests. The samples were tested and results analysed using a variety of cut-off values. The tests provided similar information although the T. congolense pre-coated plates gave significantly higher optical density values than the plates coated with T. vivax. Sensitivity and specificity values were calculated using the different cut-off points. Results indicate that the test using T. congolense antigen had the highest specificity and sensitivity for a given cut-off value. Although the test could distinguish positive from negative sera, it was quite difficult to provide a suitable cut-off value, but the value should be dictated by the use of the test. (author)

  9. c-DNA of HIV-1 detection on spot of Buffy-Coat of leukocytes (DBCS)

    OpenAIRE

    Marco Rossi de Gasperis; Maria Daniela Caione; Carlo Concato; Ersilia Fiscarelli; Nicola Di Pietro; Vittorio Salotti; Lorenza Putignani; Donato Menichella; Francesco Callea

    2010-01-01

    Introduction:The elective way for the diagnosis of HIV-1-infection in the window period and in children under the age of 16-18 months is to search virus integrated in leukocytes. Aim of the study was to assess the sensitivity and specificity of extraction from Buffy-Dried Coat Spot (DBCS) in leukocyte to detect c-DNA with nested-PCR in HIV-1-infected individuals compared to Dried Blood Spot (DBS) both extracted by automated instrument EZ1 (QIAGEN, Hilden, Germany). Both DBCS and both DBS were...

  10. Expanded envelope concepts for aircraft control-element failure detection and identification

    Science.gov (United States)

    Weiss, Jerold L.; Hsu, John Y.

    1988-01-01

    The purpose of this effort was to develop and demonstrate concepts for expanding the envelope of failure detection and isolation (FDI) algorithms for aircraft-path failures. An algorithm which uses analytic-redundancy in the form of aerodynamic force and moment balance equations was used. Because aircraft-path FDI uses analytical models, there is a tradeoff between accuracy and the ability to detect and isolate failures. For single flight condition operation, design and analysis methods are developed to deal with this robustness problem. When the departure from the single flight condition is significant, algorithm adaptation is necessary. Adaptation requirements for the residual generation portion of the FDI algorithm are interpreted as the need for accurate, large-motion aero-models, over a broad range of velocity and altitude conditions. For the decision-making part of the algorithm, adaptation may require modifications to filtering operations, thresholds, and projection vectors that define the various hypothesis tests performed in the decision mechanism. Methods of obtaining and evaluating adequate residual generation and decision-making designs have been developed. The application of the residual generation ideas to a high-performance fighter is demonstrated by developing adaptive residuals for the AFTI-F-16 and simulating their behavior under a variety of maneuvers using the results of a NASA F-16 simulation.

  11. Modification of fuel failure detection system at multi-purpose reactor RSG-GAS, BATAN

    International Nuclear Information System (INIS)

    Haruyama, Mitsuo; Shitomi, Hajime; Nakamura, Kiyoshi

    2003-03-01

    As one of the technical cooperation activity based on the Annex III, the Cooperation in the Area of Reactor Physics and Technology, of the Arrangement between the National Energy Agency (BATAN) and the Japan Atomic Energy Research Institute (JAERI), the modification of the Fuel Failure Detection System (FFDS) was carried out by the joint work at the Multi-purpose Reactor RSG-G.A. Siwabessy (RSG-GAS). The system takes the delayed neutron detection method. In normal state, as the background, it measures the gloss delayed neutron concentration emitted in the primary coolant from the fission product (FP) nuclides, which are resulted from a very small amount of fissile material contamination on the fuel plate surface at the fabrication process. When a failure happened at fuel cladding, FP leaks from the fuel meat into the primary coolant. The system shows so higher indication than at normal state, then, the fuel failure can be detected at the early stage and be minimized the damages to the reactor facility and to the environment. The system has been installed at first since November 1994 and applied for reactor operation. However, recently it is not easy to maintain the system for aging degradation and shortage of the spare units and the parts difficult to find in the markets. The modification of FFDS is required for safe and steady reactor operation. The design requirements of the modification are, - To save the system units currently used and the spares on hand as long as practicable, and/or - To replace the system units with those easy to maintain or to obtain at the markets. The modified system obtained around twice of higher sensitivity for delayed neutron detection than before and more reliable monitoring possibility with redundancy. The specification, installation, adjustment methods and characteristics of the modified system and the modus operandi of FFDS at high power reactor operation are described in this paper. (author)

  12. Analysis of arrhythmic events is useful to detect lead failure earlier in patients followed by remote monitoring.

    Science.gov (United States)

    Nishii, Nobuhiro; Miyoshi, Akihito; Kubo, Motoki; Miyamoto, Masakazu; Morimoto, Yoshimasa; Kawada, Satoshi; Nakagawa, Koji; Watanabe, Atsuyuki; Nakamura, Kazufumi; Morita, Hiroshi; Ito, Hiroshi

    2018-03-01

    Remote monitoring (RM) has been advocated as the new standard of care for patients with cardiovascular implantable electronic devices (CIEDs). RM has allowed the early detection of adverse clinical events, such as arrhythmia, lead failure, and battery depletion. However, lead failure was often identified only by arrhythmic events, but not impedance abnormalities. To compare the usefulness of arrhythmic events with conventional impedance abnormalities for identifying lead failure in CIED patients followed by RM. CIED patients in 12 hospitals have been followed by the RM center in Okayama University Hospital. All transmitted data have been analyzed and summarized. From April 2009 to March 2016, 1,873 patients have been followed by the RM center. During the mean follow-up period of 775 days, 42 lead failure events (atrial lead 22, right ventricular pacemaker lead 5, implantable cardioverter defibrillator [ICD] lead 15) were detected. The proportion of lead failures detected only by arrhythmic events, which were not detected by conventional impedance abnormalities, was significantly higher than that detected by impedance abnormalities (arrhythmic event 76.2%, 95% CI: 60.5-87.9%; impedance abnormalities 23.8%, 95% CI: 12.1-39.5%). Twenty-seven events (64.7%) were detected without any alert. Of 15 patients with ICD lead failure, none has experienced inappropriate therapy. RM can detect lead failure earlier, before clinical adverse events. However, CIEDs often diagnose lead failure as just arrhythmic events without any warning. Thus, to detect lead failure earlier, careful human analysis of arrhythmic events is useful. © 2017 Wiley Periodicals, Inc.

  13. Model-based failure detection for cylindrical shells from noisy vibration measurements.

    Science.gov (United States)

    Candy, J V; Fisher, K A; Guidry, B L; Chambers, D H

    2014-12-01

    Model-based processing is a theoretically sound methodology to address difficult objectives in complex physical problems involving multi-channel sensor measurement systems. It involves the incorporation of analytical models of both physical phenomenology (complex vibrating structures, noisy operating environment, etc.) and the measurement processes (sensor networks and including noise) into the processor to extract the desired information. In this paper, a model-based methodology is developed to accomplish the task of online failure monitoring of a vibrating cylindrical shell externally excited by controlled excitations. A model-based processor is formulated to monitor system performance and detect potential failure conditions. The objective of this paper is to develop a real-time, model-based monitoring scheme for online diagnostics in a representative structural vibrational system based on controlled experimental data.

  14. Noise diagnosis - a method for early detection of failures in a nuclear plant

    International Nuclear Information System (INIS)

    Brinckmann, H.F.

    1981-01-01

    Noise diagnosis constitutes one method for early detection of plant failures. The method is based on the fact that nearly all undesired processes in a nuclear power plant make a measurable contribution to the noise portion of signals. Well-known examples of undesired processes in pressurized water reactors include core-barrel movement, the vibration of control elements, the appearance of loose parts in the coolant flow, and the process of coolant boiling. Each of these processes has been implicated in past nuclear plant failures. In the German Democratic Republic (GDR) P. Liewers and his colleagues have introduced noise analysis systems into the primary circuit of WWER-440 pressurized water reactors (PWR). The most progressive version (RAS-II) has become a prototype for research and routine investigations. This system is described. (author)

  15. Detection of resistance mutations and CD4 slopes in individuals experiencing sustained virological failure

    DEFF Research Database (Denmark)

    Schultze, Anna; Paredes, Roger; Sabin, Caroline

    2014-01-01

    during the episode were included. Mutations were identified using the IAS-US (2013) list, and were presumed to be present from detection until the end of an episode. Multivariable linear mixed models with a random intercept and slope adjusted for age, baseline CD4 count, hepatitis C, drug type, RNA (log...... mutations on CD4 slopes in patients undergoing episodes of viral failure. MATERIALS AND METHODS: Patients from the EuroSIDA and UK CHIC cohorts undergoing at least one episode of virological failure (>3 consecutive RNA measurements >500 on ART) with at least three CD4 measurements and a resistance test......-scale), risk group and subtype were used to estimate CD4 slopes. Individual mutations with a population prevalence of >10% were tested for their effect on the CD4 slope. RESULTS: A total of 2731 patients experiencing a median of 1 (range 1-4) episodes were included in this analysis. The prevalence of any...

  16. Clad failure detection in G 3 - operational feedback; Detection de rupture de gaines G 3 - experience d'exploitation

    Energy Technology Data Exchange (ETDEWEB)

    Plisson, J [CEA Marcoule, Centre de Production de Plutonium, 30 (France)

    1964-07-01

    After briefly reviewing the role and the principles of clad failure detection, the author describes the working conditions and the conclusions reached after 4 years operation of this installation on the reactor G 3. He mentions also the modifications made to the original installation as well as the tests carried out and the experiments under way. (author) [French] Apres un rappel succinct du role et des principes de la detection de rupture de gaines, l'auteur fait un expose des conditions de fonctionnement et de l'experience tiree de 4 annees d'exploitation de cette installation sur le reacteur G 3. Il signale au passage les modifications apportees a l'installation d'origine, ainsi que les essais effectues, et les experiences en cours.

  17. Non-Destructive Failure Detection and Visualization of Artificially and Naturally Aged PV Modules

    Directory of Open Access Journals (Sweden)

    Gabriele C. Eder

    2018-04-01

    Full Text Available Several series of six-cell photovoltaic test-modules—intact and with deliberately generated failures (micro-cracks, cell cracks, glass breakage and connection defects—were artificially and naturally aged. They were exposed to various stress conditions (temperature, humidity and irradiation in different climate chambers in order to identify (i the stress-induced effects; (ii the potential propagation of the failures and (iii their influence on the performance. For comparison, one set of test-modules was also aged in an outdoor test site. All photovoltaic (PV modules were thoroughly electrically characterized by electroluminescence and performance measurements before and after the accelerated ageing and the outdoor test. In addition, the formation of fluorescence effects in the encapsulation of the test modules in the course of the accelerated ageing tests was followed over time using UV-fluorescence imaging measurements. It was found that the performance of PV test modules with mechanical module failures was rather unaffected upon storage under various stress conditions. However, numerous micro-cracks led to a higher rate of degradation. The polymeric encapsulate of the PV modules showed the build-up of distinctive fluorescence effects with increasing lifetime as the encapsulant material degraded under the influence of climatic stress factors (mainly irradiation by sunlight and elevated temperature by forming fluorophores. The induction period for the fluorescence effects of the polymeric encapsulant to be detectable was ~1 year of outdoor weathering (in middle Europe and 300 h of artificial irradiation (with 1000 W/m2 artificial sunlight 300–2500 nm. In the presence of irradiation, oxygen—which permeated into the module through the polymeric backsheet—bleached the fluorescence of the encapsulant top layer between the cells, above cell cracks and micro-cracks. Thus, UV-F imaging is a perfect tool for on-site detection of module failures

  18. Methodology description for detection of cellular uptake of PVA coated superparamagnetic iron oxide nanoparticles (SPION) in synovial cells of sheep

    International Nuclear Information System (INIS)

    Schoepf, Bernhard; Neuberger, Tobias; Schulze, Katja; Petri, Alke; Chastellain, Matthieu; Hofmann, Margarete; Hofmann, Heinrich; Rechenberg, Brigitte von

    2005-01-01

    The detection of superparamagnetic iron oxide nanoparticles (SPION) in synoviocytes is reported. Synoviocytes were incubated for 2, 12, 24 and 48 h with 1.5 mg/ml of PVA coated SPION under the influence of magnets (12 h). Particles were well tolerated by the synoviocytes, were easily detected using the Turnbulls and Prussian blue reactions between 12 and 24 h

  19. Methodology description for detection of cellular uptake of PVA coated superparamagnetic iron oxide nanoparticles (SPION) in synovial cells of sheep

    Energy Technology Data Exchange (ETDEWEB)

    Schoepf, Bernhard [Musculoskeletal Research Unit, Equine Hospital, Vetsuisse Faculty Zurich, University of Zurich, Winterthurerstr. 260, 8057 Zurich (Switzerland); Neuberger, Tobias [Musculoskeletal Research Unit, Equine Hospital, Vetsuisse Faculty Zurich, University of Zurich, Winterthurerstr. 260, 8057 Zurich (Switzerland); Schulze, Katja [Musculoskeletal Research Unit, Equine Hospital, Vetsuisse Faculty Zurich, University of Zurich, Winterthurerstr. 260, 8057 Zurich (Switzerland); Petri, Alke [Powder Technology Laboratory, Institute of Materials, Swiss Federal Institute of Technology Lausanne, EPFL, MX-D Ecublens, 1015 Lausanne (Switzerland); Chastellain, Matthieu [Powder Technology Laboratory, Institute of Materials, Swiss Federal Institute of Technology Lausanne, EPFL, MX-D Ecublens, 1015 Lausanne (Switzerland); Hofmann, Margarete [MatSearch, Ch. Jean Pavillard 14, 1009 Pully (Switzerland); Hofmann, Heinrich [Powder Technology Laboratory, Institute of Materials, Swiss Federal Institute of Technology Lausanne, EPFL, MX-D Ecublens, 1015 Lausanne (Switzerland); Rechenberg, Brigitte von [Musculoskeletal Research Unit, Equine Hospital, Vetsuisse Faculty Zurich, University of Zurich, Winterthurerstr. 260, 8057 Zurich (Switzerland)]. E-mail: bvonrechenberg@vetclinics.unizh.ch

    2005-05-15

    The detection of superparamagnetic iron oxide nanoparticles (SPION) in synoviocytes is reported. Synoviocytes were incubated for 2, 12, 24 and 48 h with 1.5 mg/ml of PVA coated SPION under the influence of magnets (12 h). Particles were well tolerated by the synoviocytes, were easily detected using the Turnbulls and Prussian blue reactions between 12 and 24 h.

  20. A neuro-fuzzy inference system for sensor failure detection using wavelet denoising, PCA and SPRT

    International Nuclear Information System (INIS)

    Na, Man Gyun

    2001-01-01

    In this work, a neuro-fuzzy inference system combined with the wavelet denoising, PCA(principal component analysis) and SPRT (sequential probability ratio test) methods is developed to detect the relevant sensor failure using other sensor signals. The wavelet denoising technique is applied to remove noise components in input signals into the neuro-fuzzy system. The PCA is used to reduce the dimension of an input space without losing a significant amount of information, The PCA makes easy the selection of the input signals into the neuro-fuzzy system. Also, a lower dimensional input space usually reduces the time necessary to train a neuro-fuzzy system. The parameters of the neuro-fuzzy inference system which estimates the relevant sensor signal are optimized by a genetic algorithm and a least-squares algorithm. The residuals between the estimated signals and the measured signals are used to detect whether the sensors are failed or not. The SPRT is used in this failure detection algorithm. The proposed sensor-monitoring algorithm was verified through applications to the pressurizer water level and the hot-leg flowrate sensors in pressurized water reactors

  1. Wavelet based edge detection algorithm for web surface inspection of coated board web

    Energy Technology Data Exchange (ETDEWEB)

    Barjaktarovic, M; Petricevic, S, E-mail: slobodan@etf.bg.ac.r [School of Electrical Engineering, Bulevar Kralja Aleksandra 73, 11000 Belgrade (Serbia)

    2010-07-15

    This paper presents significant improvement of the already installed vision system. System was designed for real time coated board inspection. The improvement is achieved with development of a new algorithm for edge detection. The algorithm is based on the redundant (undecimated) wavelet transform. Compared to the existing algorithm better delineation of edges is achieved. This yields to better defect detection probability and more accurate geometrical classification, which will provide additional reduction of waste. Also, algorithm will provide detailed classification and more reliably tracking of defects. This improvement requires minimal changes in processing hardware, only a replacement of the graphic card would be needed, adding only negligibly to the system cost. Other changes are accomplished entirely in the image processing software.

  2. Detection of gaseous fission products in water - a method of monitoring fuel sheathing failures

    Energy Technology Data Exchange (ETDEWEB)

    Tunnicliffe, P. R.; Whittier, A. C.

    1959-05-15

    The gaseous activities stripped from samples of effluent coolant from the NRU fuel elements tested in the central thimble of the NRX reactor (NRU loop) and from the NRX main effluent have been investigated. The activities obtained from the NRU loop can be attributed to gaseous fission products only. Design data have been obtained for a 'Gaseous Fission Product Monitor' to be installed for use with the NRU reactor. It is expected that this monitor will have high sensitivity to activity indicative of an incipient fuel element sheath failure. No qualitative determination of the various gaseous activities obtained from the NRX effluent has been made. A strong component of 25 {+-}1 seconds half-life is not consistent with O-19. Limited information concerning sheath failures in NRX was obtained. Of six failures observed in parallel with the installed delayed neutron monitors, three of these gave pre-warnings and in each case the gaseous fission product monitor showed a substantially greater sensitivity. An experiment in which small samples of uranium, inserted into the NRX reactor, could be exposed at will to a stream of water showed the behaviour of the two types of monitors to be similar. However, a number of signals were detected only by the gaseous fission product monitor. These can be attributed to its sensitivity to relatively long lived fission products. (author)

  3. LYAPUNOV-Based Sensor Failure Detection and Recovery for the Reverse Water Gas Shift Process

    Science.gov (United States)

    Haralambous, Michael G.

    2002-01-01

    Livingstone, a model-based AI software system, is planned for use in the autonomous fault diagnosis, reconfiguration, and control of the oxygen-producing reverse water gas shift (RWGS) process test-bed located in the Applied Chemistry Laboratory at KSC. In this report the RWGS process is first briefly described and an overview of Livingstone is given. Next, a Lyapunov-based approach for detecting and recovering from sensor failures, differing significantly from that used by Livingstone, is presented. In this new method, models used are in t e m of the defining differential equations of system components, thus differing from the qualitative, static models used by Livingstone. An easily computed scalar inequality constraint, expressed in terms of sensed system variables, is used to determine the existence of sensor failures. In the event of sensor failure, an observer/estimator is used for determining which sensors have failed. The theory underlying the new approach is developed. Finally, a recommendation is made to use the Lyapunov-based approach to complement the capability of Livingstone and to use this combination in the RWGS process.

  4. Detection of spore coat protein of Bacillus subtilis by immunological method

    International Nuclear Information System (INIS)

    Uchida, Aritsune; Kadota, Hajime

    1976-01-01

    The spore coat protein of Bacillus subtilis was separated, and the qualitative assay for the spore coat protein was made by use of the immunological technique. The immunological method was found to be useful for judging the maturation of spore coat in the course of sporulation. The spore coat protein antigen appeared at t 2 stage of sporulation. The addition of rifampicin at the earlier stages of sporulation inhibited the increase in content of the spore coat antigen. (auth.)

  5. Temperature noise analysis and sodium boiling detection in the fuel failure mockup

    International Nuclear Information System (INIS)

    Sides, W.H. Jr.; Fry, D.N.; Leavell, W.H.; Mathis, M.V.; Saxe, R.F.

    1976-01-01

    Sodium temperature noise was measured at the exit of simulated, fast-reactor fuel subassemblies in the Fuel Failure Mockup (FFM) to determine the feasibility of using temperature noise monitors to detect flow blockages in fast reactors. Also, acoustic noise was measured to determine whether sodium boiling in the FFM could be detected acoustically and whether noncondensable gas entrained in the sodium coolant would affect the sensitivity of the acoustic noise detection system. Information from these studies would be applied to the design of safety systems for operating liquid-metal fast breeder reactors (LMFBRs). It was determined that the statistical properties of temperature noise are dependent on the shape of temperature profiles across the subassemblies, and that a blockage upstream of a thermocouple that increases the gradient of the profile near the blockage will also increase the temperature noise at the thermocouple. Amplitude probability analysis of temperature noise shows a skewed amplitude density function about the mean temperature that varies with the location of the thermocouple with respect to the blockage location. It was concluded that sodium boiling in the FFM could be detected acoustically. However, entrained noncondensable gas in the sodium coolant at void fractions greater than 0.4 percent attenuated the acoustic signals sufficiently that boiling was not detected. At a void fraction of 0.1 percent, boiling was indicated only by the two acoustic detectors closest to the boiling site

  6. Plan of studies on fuel failure detection in Rikkyo Research Reactor

    International Nuclear Information System (INIS)

    Matsuura, T.; Nagahara, T.; Hattori, M.; Kawaguchi, K.

    1987-01-01

    Studies on fuel failure detection in Rikkyo Research Reactor have recently been begun in the following four approaches. (1) Accumulation of the data on the concentration of the short-lived radioactivity originating from FP rare gases contained in the air on the water surface of the reactor tank. (2) Accumulation of the data on the concentration of FP (especially 131 I) in the water of the reactor tank. (3) Design and preparation of a ''sniffer'' by which the location of the failed fuel element can be detected, when some anomaly is found in the above two routine measurements. (4) Design and preparation of a vessel containing a fuel element, which can be useful both for ''sipping'' inspection of the fuel element and for storage of the damaged fuel element. In this paper, an outline of the above approaches and the results of some preliminary experiments are reported. (author)

  7. Evaluation of a vibration diagnostic system for the detection of spur gear pitting failures

    Science.gov (United States)

    Townsend, Dennis P.; Zakrajsek, James J.

    1993-01-01

    A vibration diagnostic system was used to detect spur gear surface pitting fatigue in a closed-loop spur gear fatigue test rig. The diagnostic system, comprising a personal computer with an analog-to-digital conversion board, a diagnostic system unit, and software, uses time-synchronous averaging of the vibration signal to produce a vibration image of each tooth on any gear in a transmission. Several parameters were analyzed including gear pair stress wave and raw baseband vibration, kurtosis, peak ratios, and others. The system provides limits for the various parameters and gives a warning when the limits are exceeded. Several spur gear tests were conducted with this system and vibration data analyzed at 5-min. intervals. The results presented herein show that the system is fairly effective at detecting spur gear tooth surface fatigue pitting failures.

  8. Electrochemical detection of uric acid using ruthenium-dioxide-coated carbon nanotube directly grown onto Si wafer

    Science.gov (United States)

    Shih, Yi-Ting; Lee, Kuei-Yi; Lin, Chung-Kuang

    2015-12-01

    Carbon nanotubes (CNTs) directly grown onto a Si substrate by thermal chemical vapor deposition were used in uric acid (UA) detection. The process is simple and formation is easy without the need for additional chemical treatments. However, CNTs lack selectivity and sensitivity to UA. To enhance the electrochemical analysis, ruthenium oxide was used as a catalytic mediator in the modification of electrodes. The electrochemical results show that RuO2 nanostructures coated onto CNTs can strengthen the UA signal. The peak currents of RuO2 nanostructures coated onto CNTs linearly increase with increasing UA concentration, meaning that they can work as electrodes for UA detection. The lowest detection limit and highest sensitivity were 55 nM and 4.36 µA/µM, respectively. Moreover, the characteristics of RuO2 nanostructures coated onto CNTs were examined by scanning electron microscopy, transmission electron microscopy, and Raman spectroscopy.

  9. Efficient Flame Detection and Early Warning Sensors on Combustible Materials Using Hierarchical Graphene Oxide/Silicone Coatings.

    Science.gov (United States)

    Wu, Qian; Gong, Li-Xiu; Li, Yang; Cao, Cheng-Fei; Tang, Long-Cheng; Wu, Lianbin; Zhao, Li; Zhang, Guo-Dong; Li, Shi-Neng; Gao, Jiefeng; Li, Yongjin; Mai, Yiu-Wing

    2018-01-23

    Design and development of smart sensors for rapid flame detection in postcombustion and early fire warning in precombustion situations are critically needed to improve the fire safety of combustible materials in many applications. Herein, we describe the fabrication of hierarchical coatings created by assembling a multilayered graphene oxide (GO)/silicone structure onto different combustible substrate materials. The resulting coatings exhibit distinct temperature-responsive electrical resistance change as efficient early warning sensors for detecting abnormal high environmental temperature, thus enabling fire prevention below the ignition temperature of combustible materials. After encountering a flame attack, we demonstrate extremely rapid flame detection response in 2-3 s and excellent flame self-extinguishing retardancy for the multilayered GO/silicone structure that can be synergistically transformed to a multiscale graphene/nanosilica protection layer. The hierarchical coatings developed are promising for fire prevention and protection applications in various critical fire risk and related perilous circumstances.

  10. Detection of Taenia solium taeniasis coproantigen is an early indicator of treatment failure for taeniasis.

    Science.gov (United States)

    Bustos, Javier A; Rodriguez, Silvia; Jimenez, Juan A; Moyano, Luz M; Castillo, Yesenia; Ayvar, Viterbo; Allan, James C; Craig, Philip S; Gonzalez, Armando E; Gilman, Robert H; Tsang, Victor C W; Garcia, Hector H

    2012-04-01

    Taenia solium causes taeniasis and cysticercosis, a zoonotic complex associated with a significant burden of epilepsy in most countries. Reliable diagnosis and efficacious treatment of taeniasis are needed for disease control. Currently, cure can be confirmed only after a period of at least 1 month, by negative stool microscopy. This study assessed the performance of detection by a coproantigen enzyme-linked immunosorbent assay (CoAg-ELISA) for the early evaluation of the efficacy of antiparasitic treatment of human T. solium taeniasis. We followed 69 tapeworm carriers who received niclosamide as standard treatment. Stool samples were collected on days 1, 3, 7, 15, 30, and 90 after treatment and were processed by microscopy and CoAg-ELISA. The efficacy of niclosamide was 77.9% (53/68). Thirteen patients received a second course of treatment and completed the follow-up. CoAg-ELISA was therefore evaluated for a total of 81 cases (68 treatments, 13 retreatments). In successful treatments (n = 64), the proportion of patients who became negative by CoAg-ELISA was 62.5% after 3 days, 89.1% after 7 days, 96.9% after 15 days, and 100% after 30 days. In treatment failures (n = 17), the CoAg-ELISA result was positive for 70.6% of patients after 3 days, 94.1% after 7 days, and 100% after 15 and 30 days. Only 2 of 17 samples in cases of treatment failure became positive by microscopy by day 30. The presence of one scolex, but not multiple scolices, in posttreatment stools was strongly associated with cure (odds ratio [OR], 52.5; P taeniasis. Early assessment at day 15 would detect treatment failure before patients become infective.

  11. Sensitivity of probability-of-failure estimates with respect to probability of detection curve parameters

    Energy Technology Data Exchange (ETDEWEB)

    Garza, J. [University of Texas at San Antonio, Mechanical Engineering, 1 UTSA circle, EB 3.04.50, San Antonio, TX 78249 (United States); Millwater, H., E-mail: harry.millwater@utsa.edu [University of Texas at San Antonio, Mechanical Engineering, 1 UTSA circle, EB 3.04.50, San Antonio, TX 78249 (United States)

    2012-04-15

    A methodology has been developed and demonstrated that can be used to compute the sensitivity of the probability-of-failure (POF) with respect to the parameters of inspection processes that are simulated using probability of detection (POD) curves. The formulation is such that the probabilistic sensitivities can be obtained at negligible cost using sampling methods by reusing the samples used to compute the POF. As a result, the methodology can be implemented for negligible cost in a post-processing non-intrusive manner thereby facilitating implementation with existing or commercial codes. The formulation is generic and not limited to any specific random variables, fracture mechanics formulation, or any specific POD curve as long as the POD is modeled parametrically. Sensitivity estimates for the cases of different POD curves at multiple inspections, and the same POD curves at multiple inspections have been derived. Several numerical examples are presented and show excellent agreement with finite difference estimates with significant computational savings. - Highlights: Black-Right-Pointing-Pointer Sensitivity of the probability-of-failure with respect to the probability-of-detection curve. Black-Right-Pointing-Pointer The sensitivities are computed with negligible cost using Monte Carlo sampling. Black-Right-Pointing-Pointer The change in the POF due to a change in the POD curve parameters can be easily estimated.

  12. Sensitivity of the probability of failure to probability of detection curve regions

    International Nuclear Information System (INIS)

    Garza, J.; Millwater, H.

    2016-01-01

    Non-destructive inspection (NDI) techniques have been shown to play a vital role in fracture control plans, structural health monitoring, and ensuring availability and reliability of piping, pressure vessels, mechanical and aerospace equipment. Probabilistic fatigue simulations are often used in order to determine the efficacy of an inspection procedure with the NDI method modeled as a probability of detection (POD) curve. These simulations can be used to determine the most advantageous NDI method for a given application. As an aid to this process, a first order sensitivity method of the probability-of-failure (POF) with respect to regions of the POD curve (lower tail, middle region, right tail) is developed and presented here. The sensitivity method computes the partial derivative of the POF with respect to a change in each region of a POD or multiple POD curves. The sensitivities are computed at no cost by reusing the samples from an existing Monte Carlo (MC) analysis. A numerical example is presented considering single and multiple inspections. - Highlights: • Sensitivities of probability-of-failure to a region of probability-of-detection curve. • The sensitivities are computed with negligible cost. • Sensitivities identify the important region of a POD curve. • Sensitivities can be used as a guide to selecting the optimal POD curve.

  13. Automatic crack detection method for loaded coal in vibration failure process.

    Directory of Open Access Journals (Sweden)

    Chengwu Li

    Full Text Available In the coal mining process, the destabilization of loaded coal mass is a prerequisite for coal and rock dynamic disaster, and surface cracks of the coal and rock mass are important indicators, reflecting the current state of the coal body. The detection of surface cracks in the coal body plays an important role in coal mine safety monitoring. In this paper, a method for detecting the surface cracks of loaded coal by a vibration failure process is proposed based on the characteristics of the surface cracks of coal and support vector machine (SVM. A large number of cracked images are obtained by establishing a vibration-induced failure test system and industrial camera. Histogram equalization and a hysteresis threshold algorithm were used to reduce the noise and emphasize the crack; then, 600 images and regions, including cracks and non-cracks, were manually labelled. In the crack feature extraction stage, eight features of the cracks are extracted to distinguish cracks from other objects. Finally, a crack identification model with an accuracy over 95% was trained by inputting the labelled sample images into the SVM classifier. The experimental results show that the proposed algorithm has a higher accuracy than the conventional algorithm and can effectively identify cracks on the surface of the coal and rock mass automatically.

  14. Sensitivity of probability-of-failure estimates with respect to probability of detection curve parameters

    International Nuclear Information System (INIS)

    Garza, J.; Millwater, H.

    2012-01-01

    A methodology has been developed and demonstrated that can be used to compute the sensitivity of the probability-of-failure (POF) with respect to the parameters of inspection processes that are simulated using probability of detection (POD) curves. The formulation is such that the probabilistic sensitivities can be obtained at negligible cost using sampling methods by reusing the samples used to compute the POF. As a result, the methodology can be implemented for negligible cost in a post-processing non-intrusive manner thereby facilitating implementation with existing or commercial codes. The formulation is generic and not limited to any specific random variables, fracture mechanics formulation, or any specific POD curve as long as the POD is modeled parametrically. Sensitivity estimates for the cases of different POD curves at multiple inspections, and the same POD curves at multiple inspections have been derived. Several numerical examples are presented and show excellent agreement with finite difference estimates with significant computational savings. - Highlights: ► Sensitivity of the probability-of-failure with respect to the probability-of-detection curve. ►The sensitivities are computed with negligible cost using Monte Carlo sampling. ► The change in the POF due to a change in the POD curve parameters can be easily estimated.

  15. Detection of fine magnetic particles coated on a thread using an HTS-SQUID

    International Nuclear Information System (INIS)

    Kawagishi, K.; Itozaki, H.; Kondo, T.; Komori, K.; Koetitz, R.

    2004-01-01

    Polymer-coated magnetic particles, which contain superparamagnetic ferrite nanoparticles, were attached to a nylon thread of 0.35 mm in diameter and were detected by an HTS-SQUID. The length of the sample attached into the thread was within 3 mm and its interval was 30 mm. The particles were magnetized by a coil applied dc field or by a magnet of 1.4 T. The thread ran 2 mm under the SQUID with 20-100 mm/s of the rate. Signals of magnetic beads were detected and the peak-to-peak amplitude of the signals was directly proportional to the applied field and the weight of the magnetic particles. Obtained peak-to-peak amplitude for 20 ng of magnetite particles was 350 pT at 0.25 mT of applied dc field with noise of 18 pT, and estimated detection limit was 10 ng. S/N ratio was improved by the remanence measurement using the magnet and 5.8 ng of detection limit was obtained. This measurement has been proved to be promising for the continuous analysis of ultra dilute DNA solution

  16. A Novel Technique for Rotor Bar Failure Detection in Single-Cage Induction Motor Using FEM and MATLAB/SIMULINK

    Directory of Open Access Journals (Sweden)

    Seyed Abbas Taher

    2011-01-01

    Full Text Available In this article, a new fault detection technique is proposed for squirrel cage induction motor (SCIM based on detection of rotor bar failure. This type of fault detection is commonly carried out, while motor continues to work at a steady-state regime. Recently, several methods have been presented for rotor bar failure detection based on evaluation of the start-up transient current. The proposed method here is capable of fault detection immediately after bar breakage, where a three-phase SCIM is modelled in finite element method (FEM using Maxwell2D software. Broken rotor bars are then modelled by the corresponding outer rotor impedance obtained by GA, thereby presenting an analogue model extracted from FEM to be simulated in a flexible environment such as MATLAB/SIMULINK. To improve the failure recognition, the stator current signal was analysed using discrete wavelet transform (DWT.

  17. Electrochemical analysis of gold-coated magnetic nanoparticles for detecting immunological interaction

    International Nuclear Information System (INIS)

    Pham, Thao Thi-Hien; Sim, Sang Jun

    2010-01-01

    An electrochemical impedance immunosensor was developed for detecting the immunological interaction between human immunoglobulin (IgG) and protein A from Staphylococcus aureus based on the immobilization of human IgG on the surface of modified gold-coated magnetic nanoparticles. The nanoparticles with an Au shell and Fe oxide cores were functionalized by a self-assembled monolayer of 11-mercaptoundecanoic acid. The electrochemical analysis was conducted on the modified magnetic carbon paste electrodes with the nanoparticles. The magnetic nanoparticles were attached to the surface of the magnetic carbon paste electrodes via magnetic force. The cyclic voltammetry technique and electrochemical impedance spectroscopy measurements of the magnetic carbon paste electrodes coated with magnetic nanoparticles-human IgG complex showed changes in its alternating current (AC) response both after the modification of the surface of the electrode and the addition of protein A. The immunological interaction between human IgG on the surface of the modified magnetic carbon paste electrodes and protein A in the solution could be successfully monitored.

  18. Nitric Oxide Detection with Glassy Carbon Electrodes Coated with Charge-different Polymer Films

    Directory of Open Access Journals (Sweden)

    Jianping Lei

    2005-04-01

    Full Text Available Trace amounts of nitric oxide (NO have been determined in aqueous phosphate buffersolutions (pH=7.4 by using a glassy carbon electrode coated with three charge-different polymerfilms. The glassy carbon electrode was coated first with negatively charged Nafion film containingtetrakis(pentafluorophenylporphyrin iron(III chloride (Fe(IIITPFPP as the NO oxidation catalyst,and then with positively charged poly(acrylamide-co-diallyldimethylammonium chloride (PADDAand with neutral poly(dimethylsiloxane (silicone at the outermost layer. This polymer-coatedelectrode showed an excellent selectivity towards NO against possible concomitants in blood such asnitrite, ascorbic acid, uric acid, and dopamine. All current ratios between each concomitant and NOat the cyclic voltammogram was in 10-3 ~ 10-4. This type of electrode showed a detection limit of80 nM for NO. It was speculated from the electrochemical study in methanol that high-valent oxoiron(IV of Fe(TPFPP participated in the catalytic oxidation of NO.

  19. Novel sensing approach for LPG leakage detection: Part II: Effects of particle size, composition and coating layer thickness

    KAUST Repository

    Mukhopadhyay, Subhas

    2015-10-30

    Prominent research has been going on to develop a low-cost, efficient gas sensing system. The paper presents a continuation of our earlier research work done to develop a new sensing approach for gas detection at ambient conditions. The work exhibits the optimization of the response time of the sensor by inhabiting characteristic changes like variation in the concentration of the dispersion medium, thickness of the coating and the size of the dispersed medium. Different concentrations of the dispersion medium in the coated suspension were tested to determine the optimal composition required to achieve the highest sensitivity of the tin oxide (SnO2) layer towards the tested gas. The control over adsorption and desorption of the gas molecules in the coated layer was achieved by investigating the particle size of the dispersed medium. The response time of the coated sensor was encouraging and owns a promising potential to the development of a more efficient gas sensing system.

  20. Detection of thermally grown oxides in thermal barrier coatings by nondestructive evaluation

    Science.gov (United States)

    Fahr, A.; Rogé, B.; Thornton, J.

    2006-03-01

    The thermal-barrier coatings (TBC) sprayed on hot-section components of aircraft turbine engines commonly consist of a partially stabilized zirconia top-coat and an intermediate bond-coat applied on the metallic substrate. The bond-coat is made of an aluminide alloy that at high engine temperatures forms thermally grown oxides (TGO). Although formation of a thin layer of aluminum oxide at the interface between the ceramic top-coat and the bond-coat has the beneficial effect of protecting the metallic substrate from hot gases, oxide formation at splat boundaries or pores within the bond-coat is a source of weakness. In this study, plasma-sprayed TBC specimens are manufactured from two types of bond-coat powders and exposed to elevated temperatures to form oxides at the ceramic-bond-coat boundary and within the bond-coat. The specimens are then tested using nondestructive evaluation (NDE) and destructive metallography and compared with the as-manufactured samples. The objective is to determine if NDE can identify the oxidation within the bond-coat and give indication of its severity. While ultrasonic testing can provide some indication of the degree of bond-coat oxidation, the eddy current (EC) technique clearly identifies severe oxide formation within the bond-coat. Imaging of the EC signals as the function of probe location provides information on the spatial variations in the degree of oxidation, and thereby identifies which components or areas are prone to premature damage.

  1. Detection of Cadmium Ion by Evanescent Wave Based Chitosan Coated Optical Fiber Sensor

    International Nuclear Information System (INIS)

    Yulianti, I; Edy, S S; Saputra, B A; Aji, M P; Susanto; Kurdi, O

    2017-01-01

    Evanescent wave based-optical fiber sensor to detect cadmium ion is proposed. Chitosan was used by using the dip-coating method. The sensor was fabricated in U-bent shape. U-bent optical sensor at aconcentration of 2ppm and 5ppm had asensitivity of 0.2067 dBm/ppm and -0.7995 dBm/ppm, respectively. At a level of 2ppm - 5ppm, the optical sensor has a linear response with asensitivity of -0.283 dBm/ppm. The sensor takes 9.5 minutes to reach steady stateat aconcentration of 1 ppm. Atalevel of 2ppm - 5ppm, the sensor takes 5 minutes to 10.45 minutes to reach steady state. (paper)

  2. Etched FBG coated with polyimide for simultaneous detection the salinity and temperature

    Science.gov (United States)

    Luo, Dong; Ma, Jianxun; Ibrahim, Zainah; Ismail, Zubaidah

    2017-06-01

    In marine environment, concrete structures can corrode because of the PH alkalinity of concrete paste; and the salinity PH is heavily related with the concentration of salt in aqueous solutions. In this study, an optical fiber salinity sensor is proposed on the basis of an etched FBG (EFBG) coated with a layer of polyimide. Chemical etching is employed to reduce the diameter of FBG and to excite Cladding Mode Resonance Wavelengths (CMRWs). CMRW and Fundamental Mode Resonance Wavelength (FMRW) can be used to measure the Refractive index (RI) and temperature of salinity. The proposed sensor is then characterized with a matrix equation. Experimental results show that FMRW and 5th CMRW have the detection sensitivities of 15.407 and 125.92 nm/RIU for RI and 0.0312 and 0.0435 nm/°C for temperature, respectively. The proposed sensor can measure salinity and temperature simultaneously.

  3. Use of resonance ionization spectroscopy to detect DNA bands on ultrathin spin-coated gels.

    Science.gov (United States)

    Doktycz, M J; Gibson, W A; Arlinghaus, H F; Allen, R C; Jacobson, K B

    1993-01-01

    Development of alternative electrophoresis procedures are necessary for large volume sequencing and mapping studies. The use of stable isotopes as DNA labels and ultrathin gels promises to greatly increase the rate of sequencing. Spin coating is presented as an alternative method for producing ultrathin polyacrylamide gels. The technique has the potential of producing gels of micron to submicron thicknesses by varying the viscosity of the acrylamide solution and the spinning speed. Thirty micron thick 6% (weight %) gels were produced in this manner. Tin-labeled DNA oligomers were electrophoresed and detected using sputter-initiated resonance ionization spectroscopy (SIRIS). The usefulness of SIRIS and laser atomization RIS (LARIS) to sample the surface and deeper layers of 240 microns thick gels was investigated. With LARIS, whole cross-sections of the gel can be atomized, possibly allowing complete sampling of labels.

  4. Analyses of performance of novel sensors with different coatings for detection of Lipopolysaccharide

    KAUST Repository

    Mohd. Syaifudin, A. R.; Mukhopadhyay, Subhas Chandra; Yu, Paklam; Matias, Ignacio R.; Goicoechea, J.; Kosel, Jü rgen; Gooneratne, Chinthaka Pasan

    2011-01-01

    Interdigital sensors have been widely used for non-destructive applications. New types of planar interdigital sensors have been fabricated with different coating materials to assess the response to Lipopolysaccharide, LPS. All the coatings were

  5. A photoacoustic technique applied to detection of ethylene emissions in edible coated passion fruit

    International Nuclear Information System (INIS)

    Alves, G V L; Santos, W C dos; Vargas, H; Silva, M G da; Waldman, W R; Oliveira, J G

    2010-01-01

    Photoacoustic spectroscopy was applied to study the physiological behavior of passion fruit when coated with edible films. The results have shown a reduction of the ethylene emission rate. Weight loss monitoring has not shown any significant differences between the coated and uncoated passion fruit. On the other hand, slower color changes of coated samples suggest a slowdown of the ripening process in coated passion fruit.

  6. Detection of intra-cardiac thrombi and congestive heart failure in cats using computed tomographic angiography.

    Science.gov (United States)

    Vititoe, Kyle P; Fries, Ryan C; Joslyn, Stephen; Selmic, Laura E; Howes, Mark; Vitt, Jordan P; O'Brien, Robert T

    2018-04-16

    Arterial thromboembolism is a life-threatening condition in cats most commonly secondary to cardiac disease. Echocardiography is the reference standard to evaluate for presence of a thrombus. In humans, computed tomographic (CT) angiography is becoming widely used to detect left atrial thrombi precluding the use of sedation. The purpose of this prospective, controlled, methods comparison pilot study was threefold: (1) describe new CT angiography protocol used in awake cats with cardiac disease and congestive heart failure; (2) determine accuracy of continuous and dynamic acquisition CT angiography to identify and characterize cardiac thrombi from spontaneous echocardiographic contrast using transthoracic echocardiography as our reference standard; (3) identify known negative prognostic factors and comorbidities of the thorax that CT angiography may provide that complement or supersede echocardiographic examination. Fourteen cats with heart disease were recruited; 7 with thrombi and 7 with spontaneous echocardiographic contrast. Echocardiography and awake CT angiography were performed using a microdose of contrast. Six of 7 thrombi were identified on CT angiography as filling defects by at least one reviewer within the left auricle (n = 6) and right heart (n = 1). Highest sensitivity (71.4%) was in continuous phase and highest specificity (85.7%) was in dynamic studies with fair to moderate interobserver agreement (0.38 and 0.44). CT angiography identified prognostic cardiac information (left atrial enlargement, congestive heart failure, arterial thromboembolism) and comorbidities (suspected idiopathic pulmonary fibrosis, asthma). This study indicates CT angiography can readily identify cardiac thrombi, important prognostic information and comorbidities, and can be safely performed in cats with cardiac disease and congestive heart failure. © 2018 American College of Veterinary Radiology.

  7. Processing of Instantaneous Angular Speed Signal for Detection of a Diesel Engine Failure

    Directory of Open Access Journals (Sweden)

    Adam Charchalis

    2013-01-01

    Full Text Available Continuous monitoring of diesel engine performance under its operating is critical for the prediction of malfunction development and subsequently functional failure detection. Analysis of instantaneous angular speed (IAS of the crankshaft is considered as one of the nonintrusive and effective methods of the detection of combustion quality deterioration. In this paper results of experimental verification of fuel system's malfunction detecting, using optical encoder for IAS recording are presented. The implemented method relies on the comparison of measurement results, recorded under healthy and faulty conditions of the engine. Elaborated dynamic model of angular speed variations enables us to build templates of engine behavior. Recorded during experiment, values of cylinder pressure were taken for the approximation of pressure basic waveform. The main task of data processing is smoothing the raw angular speed signal. The noise is due to sensor mount vibrations, signal emitter machining, engine body vibrations, and crankshaft torsional vibrations. Smoothing of the measurement data was carried out by the implementation of the Savitzky-Golay filter. Measured signal after smoothing was compared with the model of IAS run.

  8. Mechanical failure of hydroxyapatite-coated titanium and cobalt-chromium-molybdenum alloy implants. An animal study

    DEFF Research Database (Denmark)

    Nimb, L; Gotfredsen, K; Steen Jensen, J

    1993-01-01

    Defects in the hydroxyapatite (HA) ceramic coatings applied to metallic implant systems may occur at the time of insertion or at the time of in vivo loading. However, defects may also occur with time because of interaction with physiological fluids. A canine study was performed to make a histolog......Defects in the hydroxyapatite (HA) ceramic coatings applied to metallic implant systems may occur at the time of insertion or at the time of in vivo loading. However, defects may also occur with time because of interaction with physiological fluids. A canine study was performed to make...

  9. Virtual Sensor for Failure Detection, Identification and Recovery in the Transition Phase of a Morphing Aircraft

    Directory of Open Access Journals (Sweden)

    Guillermo Heredia

    2010-03-01

    Full Text Available The Helicopter Adaptive Aircraft (HADA is a morphing aircraft which is able to take-off as a helicopter and, when in forward flight, unfold the wings that are hidden under the fuselage, and transfer the power from the main rotor to a propeller, thus morphing from a helicopter to an airplane. In this process, the reliable folding and unfolding of the wings is critical, since a failure may determine the ability to perform a mission, and may even be catastrophic. This paper proposes a virtual sensor based Fault Detection, Identification and Recovery (FDIR system to increase the reliability of the HADA aircraft. The virtual sensor is able to capture the nonlinear interaction between the folding/unfolding wings aerodynamics and the HADA airframe using the navigation sensor measurements. The proposed FDIR system has been validated using a simulation model of the HADA aircraft, which includes real phenomena as sensor noise and sampling characteristics and turbulence and wind perturbations.

  10. Fuel element failure detection experiments, evaluation of the experiments at KNK II/1 (Intermediate Report)

    CERN Document Server

    Bruetsch, D

    1983-01-01

    In the frame of the fuel element failure detection experiments at KNK II with its first core the measurement devices of INTERATOM were taken into operation in August 1981 and were in operation almost continuously. Since the start-up until the end of the first KNK II core operation plugs with different fuel test areas were inserted in order to test the efficiency of the different measuring devices. The experimental results determined during this test phase and the gained experiences are described in this report and valuated. All three measuring techniques (Xenon adsorption line XAS, gas-chromatograph GC and precipitator PIT) could fulfil the expectations concerning their susceptibility. For XAS and GC the nuclide specific sensitivities as determined during the preliminary tests could be confirmed. For PIT the influences of different parameters on the signal yield could be determined. The sensitivity of the device could not be measured due to a missing reference measuring point.

  11. Virtual sensor for failure detection, identification and recovery in the transition phase of a morphing aircraft.

    Science.gov (United States)

    Heredia, Guillermo; Ollero, Aníbal

    2010-01-01

    The Helicopter Adaptive Aircraft (HADA) is a morphing aircraft which is able to take-off as a helicopter and, when in forward flight, unfold the wings that are hidden under the fuselage, and transfer the power from the main rotor to a propeller, thus morphing from a helicopter to an airplane. In this process, the reliable folding and unfolding of the wings is critical, since a failure may determine the ability to perform a mission, and may even be catastrophic. This paper proposes a virtual sensor based Fault Detection, Identification and Recovery (FDIR) system to increase the reliability of the HADA aircraft. The virtual sensor is able to capture the nonlinear interaction between the folding/unfolding wings aerodynamics and the HADA airframe using the navigation sensor measurements. The proposed FDIR system has been validated using a simulation model of the HADA aircraft, which includes real phenomena as sensor noise and sampling characteristics and turbulence and wind perturbations.

  12. Using recurrent neural network models for early detection of heart failure onset.

    Science.gov (United States)

    Choi, Edward; Schuetz, Andy; Stewart, Walter F; Sun, Jimeng

    2017-03-01

    We explored whether use of deep learning to model temporal relations among events in electronic health records (EHRs) would improve model performance in predicting initial diagnosis of heart failure (HF) compared to conventional methods that ignore temporality. Data were from a health system's EHR on 3884 incident HF cases and 28 903 controls, identified as primary care patients, between May 16, 2000, and May 23, 2013. Recurrent neural network (RNN) models using gated recurrent units (GRUs) were adapted to detect relations among time-stamped events (eg, disease diagnosis, medication orders, procedure orders, etc.) with a 12- to 18-month observation window of cases and controls. Model performance metrics were compared to regularized logistic regression, neural network, support vector machine, and K-nearest neighbor classifier approaches. Using a 12-month observation window, the area under the curve (AUC) for the RNN model was 0.777, compared to AUCs for logistic regression (0.747), multilayer perceptron (MLP) with 1 hidden layer (0.765), support vector machine (SVM) (0.743), and K-nearest neighbor (KNN) (0.730). When using an 18-month observation window, the AUC for the RNN model increased to 0.883 and was significantly higher than the 0.834 AUC for the best of the baseline methods (MLP). Deep learning models adapted to leverage temporal relations appear to improve performance of models for detection of incident heart failure with a short observation window of 12-18 months. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  13. Instrument failure detection of flow measurement in the feedwater system of the Paks Nuclear Power Plant, Hungary

    International Nuclear Information System (INIS)

    Racz, A.

    1990-12-01

    The applicability of two different methods for early detection of instrument failures of the flow measurement in feedwater systems are investigated. Both methods are based on Kalman filtering technique of stochastic processes. The reliability of the model for description of a feedwater system is checked by comparing calculated values with measured data. Possible instrument failures are simulated in order to show the capability of the proposed procedures. A practical measurement system arrangement is suggested. (author) 10 refs.; 16 figs.; 4 tabs

  14. Detection of smaller J{sub c} region and damage in YBCO coated conductors by using permanent magnet method

    Energy Technology Data Exchange (ETDEWEB)

    Hattori, K., E-mail: tey88221@st.yamagata-u.ac.jp [Graduate School of Science and Engineering, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510 (Japan); Saito, A. [Graduate School of Science and Engineering, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510 (Japan); Takano, Y.; Suzuki, T. [Tohoku Seiki Industries, Ltd., 3-1246, Tachiyagawa, Yamagata 990-2251 (Japan); Yamada, H.; Takayama, T.; Kamitani, A.; Ohshima, S. [Graduate School of Science and Engineering, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510 (Japan)

    2011-11-15

    We developed a non-destructive method for measuring the critical current density (J{sub c}) in YBCO-coated conductors by using a permanent magnet (Sm{sub 2}Co{sub 17}). J{sub c} could be determined from the repulsive force (F{sub r}) generated between a permanent magnet and a coated conductor where shielding current flows. We also examined the influence of damage to the film on the J{sub c} distribution. The measured F{sub r} when the permanent magnet approached the cut part was smaller than that of the undamaged area. We developed a non-destructive method for measuring the critical current density (J{sub c}) in YBCO-coated conductors by using a permanent magnet (Sm{sub 2}Co{sub 17}). J{sub c} could be determined from the repulsive force (F{sub r}) generated between a permanent magnet and a coated conductor where shielding current flows. We tried to detect a smaller J{sub c} region in the coated conductor by using the system. The J{sub c} distribution could be determined without influence from the thick copper film on YBCO thin film. We also examined the influence of damage to the film on the J{sub c} distribution. The surface of the coated conductors was cut by using a knife. The measured F{sub r} when the permanent magnet approached the cut part was smaller than that of the undamaged area. This J{sub c} measurement technique will be useful for detecting smaller J{sub c} regions and defects in coated conductors.

  15. Long-Term Stability of Polymer-Coated Surface Transverse Wave Sensors for the Detection of Organic Solvent Vapors.

    Science.gov (United States)

    Stahl, Ullrich; Voigt, Achim; Dirschka, Marian; Barié, Nicole; Richter, Christiane; Waldbaur, Ansgar; Gruhl, Friederike J; Rapp, Bastian E; Rapp, Michael; Länge, Kerstin

    2017-11-03

    Arrays with polymer-coated acoustic sensors, such as surface acoustic wave (SAW) and surface transverse wave (STW) sensors, have successfully been applied for a variety of gas sensing applications. However, the stability of the sensors' polymer coatings over a longer period of use has hardly been investigated. We used an array of eight STW resonator sensors coated with different polymers. This sensor array was used at semi-annual intervals for a three-year period to detect organic solvent vapors of three different chemical classes: a halogenated hydrocarbon (chloroform), an aliphatic hydrocarbon (octane), and an aromatic hydrocarbon (xylene). The sensor signals were evaluated with regard to absolute signal shifts and normalized signal shifts leading to signal patterns characteristic of the respective solvent vapors. No significant time-related changes of sensor signals or signal patterns were observed, i.e., the polymer coatings kept their performance during the course of the study. Therefore, the polymer-coated STW sensors proved to be robust devices which can be used for detecting organic solvent vapors both qualitatively and quantitatively for several years.

  16. c-DNA of HIV-1 detection on spot of Buffy-Coat of leukocytes (DBCS

    Directory of Open Access Journals (Sweden)

    Marco Rossi de Gasperis

    2010-03-01

    Full Text Available Introduction:The elective way for the diagnosis of HIV-1-infection in the window period and in children under the age of 16-18 months is to search virus integrated in leukocytes. Aim of the study was to assess the sensitivity and specificity of extraction from Buffy-Dried Coat Spot (DBCS in leukocyte to detect c-DNA with nested-PCR in HIV-1-infected individuals compared to Dried Blood Spot (DBS both extracted by automated instrument EZ1 (QIAGEN, Hilden, Germany. Both DBCS and both DBS were compared with those tests from whole blood by conventional DNA-extraction Methods: Five ml of whole blood from 50 HIV-infected individuals were collected. 40 μl of each sample were spotted on “FTA ELUTE Micro Card” (Whatman, Inc., Clifton, NJ, 200 μl were extracted according to the manual procedure (QIAGEN “QIAamp DNA minikit and the remaining sample was incubated at 37 °C for 120 minutes. Plasma was centrifuged at 1000 rcf/1g for 10 minutes at room temperature. Forty μl of the obtained buffy-coat was spotted. Both DBCS and both DBS were dried at room temperature for 24 hours.Two of 5 punch from each spot were extracted with TISSUE DNA kit (Biorobot EZ1 DSP “Qiagen” and eluted in 50 μl of buffer.The recovery of genomic DNA was measured amplifying the ß-globin gene by Real-Time “SybrGreen I”.The DNA was amplified for the “pol” gene of HIV-1 by nested PCR and revealed in “SYBR-green I”. Eight HIV-antibody-negative samples were used as internal control. Results:The experimental protocol adopted for the DBCS showed high sensitivity and specificity.The extracted DNA from DBS and DBCS was characterized by excellent quality and without any inhibitory agents. The amount of proviral DNA extracted from DBCS is similar to that obtained by conventional extraction, while the DBS test was significantly less sensitive. Conclusion:These preliminary data suggest that the amount of c-DNA obtained with DBS technique is often not enough for the

  17. Detection of Trypanosoma congolense type savannah in field samples of buffy coats of bovins using PCR-ELISA

    International Nuclear Information System (INIS)

    Sidibe, I.

    2007-01-01

    PCR-ELISA was set up to detect strain of Trypanosoma congolense type savannah in field samples of buffy coats. Results of PCR-ELISA and PCR were compared and the sensibility and specificity of both techniques were also compared with those of the method of Murray [1] for the detection of TCS in 257 samples. The PCR products were labelling with DIG-dUTP during amplification cycles of the repetitive satellite DNA. A DNA biotinyled capture probe was used to detect the amplicon by ELISA in streptavidine coated microplates. Both of PCR-ELISA and PCR were more sensible and more specific than the method of Murray. Indeed, for the 257 samples analysed by the three techniques, PCR-ELISA and PCR have detected TCS in 98 and 97 samples respectively, whereas the method of Murray has detected TCS in only 39 samples. In addition, PCRELISA and PCR had almost the same sensibility and specificity. So, PCR-ELISA and PCR have respectively detected TCS in 38.62% and 39.22% of all the 334 samples analysed by both techniques during this study. At the end of this study, the cost of analyse by PCR-ELISA of a sample of buffy coat, was evaluated at 1993 FCFA or Euro 3,04. (author) [fr

  18. RGO-coated elastic fibres as wearable strain sensors for full-scale detection of human motions

    Science.gov (United States)

    Mi, Qing; Wang, Qi; Zang, Siyao; Mao, Guoming; Zhang, Jinnan; Ren, Xiaomin

    2018-01-01

    In this study, we chose highly-elastic fabric fibres as the functional carrier and then simply coated the fibres with reduced graphene oxide (rGO) using plasma treatment, dip coating and hydrothermal reduction steps, finally making a wearable strain sensor. As a result, the full-scale detection of human motions, ranging from bending joints to the pulse beat, has been achieved by these sensors. Moreover, high sensitivity, good stability and excellent repeatability were realized. The good sensing performances and economical fabrication process of this wearable strain sensor have strengthened our confidence in practical applications in smart clothing, smart fabrics, healthcare, and entertainment fields.

  19. Inversion Method for Early Detection of ARES-1 Case Breach Failure

    Science.gov (United States)

    Mackey, Ryan M.; Kulikov, Igor K.; Bajwa, Anupa; Berg, Peter; Smelyanskiy, Vadim

    2010-01-01

    A document describes research into the problem of detecting a case breach formation at an early stage of a rocket flight. An inversion algorithm for case breach allocation is proposed and analyzed. It is shown how the case breach can be allocated at an early stage of its development by using the rocket sensor data and the output data from the control block of the rocket navigation system. The results are simulated with MATLAB/Simulink software. The efficiency of an inversion algorithm for a case breach location is discussed. The research was devoted to the analysis of the ARES-l flight during the first 120 seconds after the launch and early prediction of case breach failure. During this time, the rocket is propelled by its first-stage Solid Rocket Booster (SRB). If a breach appears in SRB case, the gases escaping through it will produce the (side) thrust directed perpendicular to the rocket axis. The side thrust creates torque influencing the rocket attitude. The ARES-l control system will compensate for the side thrust until it reaches some critical value, after which the flight will be uncontrollable. The objective of this work was to obtain the start time of case breach development and its location using the rocket inertial navigation sensors and GNC data. The algorithm was effective for the detection and location of a breach in an SRB field joint at an early stage of its development.

  20. Use of buffy coat thick films in detecting malaria parasites in patients with negative conventional thick films.

    Science.gov (United States)

    Duangdee, Chatnapa; Tangpukdee, Noppadon; Krudsood, Srivicha; Wilairatana, Polrat

    2012-04-01

    To determine the frequency of malaria parasite detection from the buffy coat blood films by using capillary tube in falciparum malaria patients with negative conventional thick films. Thirty six uncomplicated falciparum malaria patients confirmed by conventional thick and thin films were included in the study. The patients were treated with artemisinin combination therapy at Hospital for Tropical Diseases, Bangkok, Thailand for 28 day. Fingerpricks for conventional blood films were conducted every 6 hours until negative parasitemia, then daily fingerpricks for parasite checks were conducted until the patients were discharged from hospital. Blood samples were also concurrently collected in 3 heparinized capillary tubes at the same time of fingerpricks for conventional blood films when the prior parasitemia was negative on thin films and parasitemia was lower than 50 parasites/200 white blood cells by thick film. The first negative conventional thick films were compared with buffy coat thick films for parasite identification. Out of 36 patients with thick films showing negative for asexual forms of parasites, buffy coat films could detect remaining 10 patients (27.8%) with asexual forms of Plasmodium falciparum. The study shows that buffy coat thick films are useful and can detect malarial parasites in 27.8% of patients whose conventional thick films show negative parasitemia.

  1. Detection of hydrogen in hidden and spalled layers of turbine blade coatings

    Energy Technology Data Exchange (ETDEWEB)

    Zschau, H.-E. [DECHEMA e. V., Karl-Winnacker-Institut, Theodor-Heuss-Allee 25, D-60486 Frankfurt (Germany)]. E-mail: zschau@dechema.de; Dietrich, M. [DECHEMA e. V., Karl-Winnacker-Institut, Theodor-Heuss-Allee 25, D-60486 Frankfurt (Germany); Renusch, D. [DECHEMA e. V., Karl-Winnacker-Institut, Theodor-Heuss-Allee 25, D-60486 Frankfurt (Germany); Schuetze, M. [DECHEMA e. V., Karl-Winnacker-Institut, Theodor-Heuss-Allee 25, D-60486 Frankfurt (Germany); Meijer, J. [Ruhr-Universitaet-Bochum, Dynamitron-Tandem-Labor, Universitaetsstr. 150, D-44801 Bochum (Germany); Becker, H.-W. [Ruhr-Universitaet-Bochum, Dynamitron-Tandem-Labor, Universitaetsstr. 150, D-44801 Bochum (Germany)

    2006-08-15

    Gas turbine blades are covered with an outer ceramic top coat and an inner metallic bond coat, namely a thermal barrier coating system (TBC). The stability of the TBC is strongly influenced by the thermally growing oxide (TGO) which forms between the top and bond coat during turbine operation. This work is focused on the role of hydrogen in the adhesion of the top coat after oxidation at 1100 deg. C in dry and wet air at various time steps between 75 and 1150 h. To obtain the essential hydrogen information from the TGO the nuclear reaction {sup 1}H({sup 15}N, {alpha}{gamma}){sup 12}C is used with a unique scattering chamber (SDIBA). This equipment combines the defined exfoliation of the top coat by using a 4-points bending mechanism followed by IBA. This allows the determination of hydrogen concentration depth profiles at the TGO and first results are presented.

  2. Effects of surface coatings on the light collection in plastic scintillators used for radioxenon detection

    International Nuclear Information System (INIS)

    Bläckberg, L; Klintenberg, M; Sjöstrand, H; Ringbom, A

    2012-01-01

    Atomic layer deposition coatings are under investigation to reduce the diffusion of radioxenon into plastic scintillators. This paper investigates the impact of such surface coating on the light collection efficiency in a cylindrical geometry. A high and uniform light collection efficiency is important to preserve detector resolution. Monte Carlo simulations and measurements have been carried out to study the influence of coating thickness, refractive index and surface quality. It was found that it is important to achieve a smooth coating and good optical match between the refractive indices of the coating and the plastic scintillator. Taking into account these considerations, the detector under study could be coated without a significant degradation of its resolution.

  3. Zeolitic imidazolate framework-coated acoustic sensors for room temperature detection of carbon dioxide and methane.

    Science.gov (United States)

    Devkota, Jagannath; Kim, Ki-Joong; Ohodnicki, Paul R; Culp, Jeffrey T; Greve, David W; Lekse, Jonathan W

    2018-05-03

    The integration of nanoporous materials such as metal organic frameworks (MOFs) with sensitive transducers can result in robust sensing platforms for monitoring gases and chemical vapors for a range of applications. Here, we report on an integration of the zeolitic imidazolate framework - 8 (ZIF-8) MOF with surface acoustic wave (SAW) and thickness shear mode quartz crystal microbalance (QCM) devices to monitor carbon dioxide (CO2) and methane (CH4) under ambient conditions. The MOF was directly coated on the Y-Z LiNbO3 SAW delay lines (operating frequency, f0 = 436 MHz) and AT-cut quartz TSM resonators (resonant frequency, f0 = 9 MHz) and the devices were tested for various gases in N2 under ambient conditions. The devices were able to detect the changes in CO2 or CH4 concentrations with relatively higher sensitivity to CO2, which was due to its higher adsorption potential and heavier molecular weight. The sensors showed full reversibility and repeatability which were attributed to the physisorption of the gases into the MOF and high stability of the devices. Both types of sensors showed linear responses relative to changes in the binary gas compositions thereby allowing to construct calibration curves which correlated well with the expected mass changes in the sorbent layer based on mixed-gas gravimetric adsorption isotherms measured on bulk samples. For 200 nm thick films, the SAW sensitivities to CO2 and CH4 were 1.44 × 10-6/vol% and 8 × 10-8/vol%, respectively, against the QCM sensitivities 0.24 × 10-6/vol% and 1 × 10-8/vol%, respectively, which were evaluated as the fractional change in the signal. The SAW sensors were also evaluated for 100 nm-300 nm thick films, the sensitivities of which were found to increase with the thickness due to the increased number of pores for the adsorption of a larger amount of gases. In addition, the MOF-coated SAW delay lines had a good response in wireless mode, demonstrating their potential to operate remotely for the

  4. Optical detection of glucose and glycated hemoglobin using etched fiber Bragg gratings coated with functionalized reduced graphene oxide.

    Science.gov (United States)

    Sridevi, S; Vasu, K S; Sampath, S; Asokan, S; Sood, A K

    2016-07-01

    An enhanced optical detection of D-glucose and glycated hemoglobin (HbA1c ) has been established in this study using etched fiber Bragg gratings (eFBG) coated with aminophenylboronic acid (APBA)-functionalized reduced graphene oxide (RGO). The read out, namely the shift in Bragg wavelength (ΔλB ) is highly sensitive to changes that occur due to the adsorption of glucose (or HbA1c ) molecules on the eFBG sensor coated with APBA-RGO complex through a five-membered cyclic ester bond formation between glucose and APBA molecules. A limit of detection of 1 nM is achieved with a linear range of detection from 1 nM to 10 mM in the case of D-glucose detection experiments. For HbA1c , a linear range of detection varying from 86 nM to 0.23 mM is achieved. The observation of only 4 pm (picometer) change in ΔλB even for the 10 mM lactose solution confirms the specificity of the APBA-RGO complex coated eFBG sensors to glucose molecules. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Memory effect, resolution, and efficiency measurements of an Al2O3 coated plastic scintillator used for radioxenon detection

    International Nuclear Information System (INIS)

    Bläckberg, L.; Fritioff, T.; Mårtensson, L.; Nielsen, F.; Ringbom, A.; Sjöstrand, H.; Klintenberg, M.

    2013-01-01

    A cylindrical plastic scintillator cell, used for radioxenon monitoring within the verification regime of the Comprehensive Nuclear-Test-Ban Treaty, has been coated with 425 nm Al 2 O 3 using low temperature Atomic Layer Deposition, and its performance has been evaluated. The motivation is to reduce the memory effect caused by radioxenon diffusing into the plastic scintillator material during measurements, resulting in an elevated detection limit. Measurements with the coated detector show both energy resolution and efficiency comparable to uncoated detectors, and a memory effect reduction of a factor of 1000. Provided that the quality of the detector is maintained for a longer period of time, Al 2 O 3 coatings are believed to be a viable solution to the memory effect problem in question

  6. Memory effect, resolution, and efficiency measurements of an Al2O3 coated plastic scintillator used for radioxenon detection

    Science.gov (United States)

    Bläckberg, L.; Fritioff, T.; Mårtensson, L.; Nielsen, F.; Ringbom, A.; Sjöstrand, H.; Klintenberg, M.

    2013-06-01

    A cylindrical plastic scintillator cell, used for radioxenon monitoring within the verification regime of the Comprehensive Nuclear-Test-Ban Treaty, has been coated with 425 nm Al2O3 using low temperature Atomic Layer Deposition, and its performance has been evaluated. The motivation is to reduce the memory effect caused by radioxenon diffusing into the plastic scintillator material during measurements, resulting in an elevated detection limit. Measurements with the coated detector show both energy resolution and efficiency comparable to uncoated detectors, and a memory effect reduction of a factor of 1000. Provided that the quality of the detector is maintained for a longer period of time, Al2O3 coatings are believed to be a viable solution to the memory effect problem in question.

  7. On-line detection of key radionuclides for fuel-rod failure in a pressurized water reactor.

    Science.gov (United States)

    Qin, Guoxiu; Chen, Xilin; Guo, Xiaoqing; Ni, Ning

    2016-08-01

    For early on-line detection of fuel rod failure, the key radionuclides useful in monitoring must leak easily from failing rods. Yield, half-life, and mass share of fission products that enter the primary coolant also need to be considered in on-line analyses. From all the nuclides that enter the primary coolant during fuel-rod failure, (135)Xe and (88)Kr were ultimately chosen as crucial for on-line monitoring of fuel-rod failure. A monitoring system for fuel-rod failure detection for pressurized water reactor (PWR) based on the LaBr3(Ce) detector was assembled and tested. The samples of coolant from the PWR were measured using the system as well as a HPGe γ-ray spectrometer. A comparison showed the method was feasible. Finally, the γ-ray spectra of primary coolant were measured under normal operations and during fuel-rod failure. The two peaks of (135)Xe (249.8keV) and (88)Kr (2392.1keV) were visible, confirming that the method is capable of monitoring fuel-rod failure on-line. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Fabrication of Stretchable Copper Coated Carbon Nanotube Conductor for Non-Enzymatic Glucose Detection Electrode with Low Detection Limit and Selectivity

    Directory of Open Access Journals (Sweden)

    Dawei Jiang

    2018-03-01

    Full Text Available The increasing demand for wearable glucose sensing has stimulated growing interest in stretchable electrodes. The development of the electrode materials having large stretchability, low detection limit, and good selectivity is the key component for constructing high performance wearable glucose sensors. In this work, we presented fabrication of stretchable conductor based on the copper coated carbon nanotube sheath-core fiber, and its application as non-enzymatic electrode for glucose detection with high stretchability, low detection limit, and selectivity. The sheath-core fiber was fabricated by coating copper coated carbon nanotube on a pre-stretched rubber fiber core followed by release of pre-stretch, which had a hierarchically buckled structure. It showed a small resistance change as low as 27% as strain increasing from 0% to 500% strain, and a low resistance of 0.4 Ω·cm−1 at strain of 500%. This electrode showed linear glucose concentration detection in the range between 0.05 mM and 5 mM and good selectivity against sucrose, lactic acid, uric acid, acrylic acid in phosphate buffer saline solution, and showed stable signal in high salt concentration. The limit of detection (LOD was 0.05 mM, for the range of 0.05–5 mM, the sensitivity is 46 mA·M−1. This electrode can withstand large strain of up to 60% with negligible influence on its performance.

  9. ppt level detection of samarium(III) with a coated graphite sensor based on an antibiotic.

    Science.gov (United States)

    Ganjali, Mohammad Reza; Rezapour, Morteza; Pourjavid, Mohammad Reza; Haghgoo, Soheila

    2004-07-01

    N-[2-[4-[[[(Cyclohexylamino)carbonyl]amino]sulfonyl]phenyl]ethyl]-5-methyl pyrazine carboxamide (glipizid) was explored as an electro-active material for preparing a polymeric membrane-based sensor selective to samarium ions. The membrane incorporated 30% poly(vinyl chloride) (PVC), 53% benzyl acetate (BA), 11% glipizid and 6% sodium tetraphenyl borate. When coated on the surface of a graphite electrode, it exhibits Nernstian responses in the concentration range of 1.0 x 10(-5) to 1.0 x 10(-10) M, with a detection limit of 8.0 x 10(-11)M samarium. The electrode shows high selectivity towards samarium over several cations (alkali, alkaline earth, transition and heavy metal ions), and specially lanthanide ions. The proposed sensor has a very short response time (pH range for at least ten weeks. It was used as an indicator electrode in potentiometric titration of Sm(III) ions with an EDTA solution, and for determination of samarium in binary and ternary mixtures.

  10. System to detect and protect a failure during start-up of pumping-up; Yosui shidochu no jikokenshutsu hogo hoshiki

    Energy Technology Data Exchange (ETDEWEB)

    Hagiwara, H. [Kansai Electric Power Co. Inc., Osaka (Japan)

    1999-12-10

    Development was made on a method to detect and protect a failure in a power generation motor operating at a rotation speed other than the rated speed, such as in start-up of pumping-up. Such a failure may not be detected from the ordinary frequency characteristics because the failure current due to short circuit or earth failure is lower than the rated frequency. An idea was conceived to detect flow of low frequency failure current on the armature side by detecting change in the field current being a phenomenal change in the armature current. To realize the idea, the simulation circuits of the parent and child motors of the power generation motors were modeled and verified. The following results were obtained from the verification of a three-phase short circuit failure: when the field current is constant, the failure current is nearly constant regardless of the operating frequency; the failure current flows into the field circuit; because the trajectory of the low frequency overcurrent in the main circuit flowing in case of operation in a low frequency zone presents the similar trajectory to that in 60-Hz operation, the failure may be detected from variation in the field current; and the protection activity after the failure detection is to release the excitation, and attenuate the failure current. (NEDO)

  11. Analysis of different coating thickness on new type of planar interdigital sensors for endotoxin detection

    KAUST Repository

    Syaifudin, A. R Mohd

    2013-05-01

    New types of planar interdigital sensors have been fabricated on Silicon/Silicon Dioxide (Si/SiO2) wafers. The sensors were coated with pre-cursor silica functionalized with APTES (3-aminopropyltrietoxysilane) at different thicknesses. All sensors were then immobilized with Polymyxin, B (PmB). PmB is an antimicrobial peptide produced by the Gram-positive bacterium-Bacillus, has been immobilized on the coated sensors because of its specific binding properties to endotoxin. Studies were conducted to analyze the effect of different thicknesses of coatings on the sensitivity and selectivity of the sensors. It was observed sensors coated with 3 layers of coating has better sensitivity and selectivity to the target molecules (endotoxin) compared to sensors with 5 layers of coating. The repeatability and stability of the coated sensors were tested by multiple standard endotoxin measurement and it was observed that the sensors give a good reproducibility and stability up to six continuous measurements before the coating degrades. © 2013 IEEE.

  12. A preliminary evaluation of the generalized likelihood ratio for detecting and identifying control element failures in a transport aircraft

    Science.gov (United States)

    Bundick, W. T.

    1985-01-01

    The application of the Generalized Likelihood Ratio technique to the detection and identification of aircraft control element failures has been evaluated in a linear digital simulation of the longitudinal dynamics of a B-737 aircraft. Simulation results show that the technique has potential but that the effects of wind turbulence and Kalman filter model errors are problems which must be overcome.

  13. Failure of PCR to Detect Treponema pallidum ssp. pertenue DNA in Blood in Latent Yaws.

    Directory of Open Access Journals (Sweden)

    Michael Marks

    Full Text Available Yaws, caused by Treponema pallidum ssp. pertenue, is a neglected tropical disease closely related to venereal syphilis and is targeted for eradication by 2020. Latent yaws represents a diagnostic challenge, and current tools cannot adequately distinguish between individuals with true latent infection and individuals who are serofast following successful treatment. PCR on blood has previously been shown to detect T. pallidum DNA in patients with syphilis, suggesting that this approach may be of value in yaws. We performed real-time PCR for Treponema pallidum ssp. pertenue on blood samples from 140 children with positive T. pallidum Particle Agglutination (TPPA and Rapid Plasma Reagin (RPR tests and 7 controls (negative serology, all collected as part of a prospective study of yaws in the Solomon Islands. All samples were also tested by a nested PCR for T. pallidum. 12 patients had clinical evidence of active yaws whilst 128 were considered to have latent yaws. 43 children had high titre rapid plasma reagins (RPRs of ≥1:32. PCR testing with both assays gave negative results in all cases. It is possible that the failure to detect T. pallidum ssp. pertenue in blood reflects lower loads of organism in latent yaws compared to those in latent infection with T. pallidum ssp. pertenue, and/or a lower propensity for haematogenous dissemination in yaws than in syphilis. As the goal of the yaws control programme is eradication, a tool that can differentiate true latent infection from individuals who are serofast would be of value; however, PCR of blood is not that tool.

  14. Failure of PCR to Detect Treponema pallidum ssp. pertenue DNA in Blood in Latent Yaws.

    Science.gov (United States)

    Marks, Michael; Katz, Samantha; Chi, Kai-Hua; Vahi, Ventis; Sun, Yongcheng; Mabey, David C; Solomon, Anthony W; Chen, Cheng Y; Pillay, Allan

    2015-01-01

    Yaws, caused by Treponema pallidum ssp. pertenue, is a neglected tropical disease closely related to venereal syphilis and is targeted for eradication by 2020. Latent yaws represents a diagnostic challenge, and current tools cannot adequately distinguish between individuals with true latent infection and individuals who are serofast following successful treatment. PCR on blood has previously been shown to detect T. pallidum DNA in patients with syphilis, suggesting that this approach may be of value in yaws. We performed real-time PCR for Treponema pallidum ssp. pertenue on blood samples from 140 children with positive T. pallidum Particle Agglutination (TPPA) and Rapid Plasma Reagin (RPR) tests and 7 controls (negative serology), all collected as part of a prospective study of yaws in the Solomon Islands. All samples were also tested by a nested PCR for T. pallidum. 12 patients had clinical evidence of active yaws whilst 128 were considered to have latent yaws. 43 children had high titre rapid plasma reagins (RPRs) of ≥1:32. PCR testing with both assays gave negative results in all cases. It is possible that the failure to detect T. pallidum ssp. pertenue in blood reflects lower loads of organism in latent yaws compared to those in latent infection with T. pallidum ssp. pertenue, and/or a lower propensity for haematogenous dissemination in yaws than in syphilis. As the goal of the yaws control programme is eradication, a tool that can differentiate true latent infection from individuals who are serofast would be of value; however, PCR of blood is not that tool.

  15. Improved detection of congestive heart failure via probabilistic symbolic pattern recognition and heart rate variability metrics.

    Science.gov (United States)

    Mahajan, Ruhi; Viangteeravat, Teeradache; Akbilgic, Oguz

    2017-12-01

    A timely diagnosis of congestive heart failure (CHF) is crucial to evade a life-threatening event. This paper presents a novel probabilistic symbol pattern recognition (PSPR) approach to detect CHF in subjects from their cardiac interbeat (R-R) intervals. PSPR discretizes each continuous R-R interval time series by mapping them onto an eight-symbol alphabet and then models the pattern transition behavior in the symbolic representation of the series. The PSPR-based analysis of the discretized series from 107 subjects (69 normal and 38 CHF subjects) yielded discernible features to distinguish normal subjects and subjects with CHF. In addition to PSPR features, we also extracted features using the time-domain heart rate variability measures such as average and standard deviation of R-R intervals. An ensemble of bagged decision trees was used to classify two groups resulting in a five-fold cross-validation accuracy, specificity, and sensitivity of 98.1%, 100%, and 94.7%, respectively. However, a 20% holdout validation yielded an accuracy, specificity, and sensitivity of 99.5%, 100%, and 98.57%, respectively. Results from this study suggest that features obtained with the combination of PSPR and long-term heart rate variability measures can be used in developing automated CHF diagnosis tools. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Magnetic relaxation switch and colorimetric detection of thrombin using aptamer-functionalized gold-coated iron oxide nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Liang Guohai; Cai Shaoyu; Zhang Peng [Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai 200433 (China); Peng Youyuan [Department of Chemistry, Quanzhou Normal University, Quanzhou 362000 (China); Chen Hui; Zhang Song [Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai 200433 (China); Kong Jilie, E-mail: jlkong@fudan.edu.cn [Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai 200433 (China)

    2011-03-18

    We describe a sensitive biosensing system combining magnetic relaxation switch diagnosis and colorimetric detection of human {alpha}-thrombin, based on the aptamer-protein interaction induced aggregation of Fe{sub 3}O{sub 4}-Au nanoparticles. To demonstrate the concept, gold-coated iron oxide nanoparticle was synthesized by iterative reduction of HAuCl{sub 4} onto the dextran-coated Fe{sub 3}O{sub 4} nanoparticles. The resulting core-shell structure had a flowerlike shape with pretty narrow size distribution (referred to as 'nanorose'). The two aptamers corresponding to human {alpha}-thrombin were conjugated separately to two distinct nanorose populations. Once a solution containing human {alpha}-thrombin was introduced, the nanoroses switched from a well dispersed state to an aggregated one, leading to a change in the spin-spin relaxation time (T{sub 2}) as well as the UV-Vis absorption spectra of the solution. Thus the qualitative and quantitative detection method for human {alpha}-thrombin was established. The dual-mode detection is clearly advantageous in obtaining a more reliable result; the detection range is widened as well. By using the dual-mode detection method, a detectable T{sub 2} change is observed with 1.0 nM human {alpha}-thrombin, and the detection range is from 1.6 nM to 30.4 nM.

  17. Metaiodobenzylguanidine [131I] scintigraphy detects impaired myocardial sympathetic neuronal transport function of canine mechanical-overload heart failure

    International Nuclear Information System (INIS)

    Rabinovitch, M.A.; Rose, C.P.; Rouleau, J.L.

    1987-01-01

    In heart failure secondary to chronic mechanical overload, cardiac sympathetic neurons demonstrate depressed catecholamine synthetic and transport function. To assess the potential of sympathetic neuronal imaging for detection of depressed transport function, serial scintigrams were acquired after the intravenous administration of metaiodobenzylguanidine [ 131 I] to 13 normal dogs, 3 autotransplanted (denervated) dogs, 5 dogs with left ventricular failure, and 5 dogs with compensated left ventricular hypertrophy due to a surgical arteriovenous shunt. Nine dogs were killed at 14 hours postinjection for determination of metaiodobenzylguanidine [ 131 I] and endogenous norepinephrine content in left atrium, left ventricle, liver, and spleen. By 4 hours postinjection, autotransplanted dogs had a 39% reduction in mean left ventricular tracer accumulation, reflecting an absent intraneuronal tracer pool. Failure dogs demonstrated an accelerated early mean left ventricular tracer efflux rate (26.0%/hour versus 13.7%/hour in normals), reflecting a disproportionately increased extraneuronal tracer pool. They also showed reduced late left ventricular and left atrial concentrations of tracer, consistent with a reduced intraneuronal tracer pool. By contrast, compensated hypertrophy dogs demonstrated a normal early mean left ventricular tracer efflux rate (16.4%/hour) and essentially normal late left ventricular and left atrial concentrations of tracer. Metaiodobenzylguanidine [ 131 I] scintigraphic findings reflect the integrity of the cardiac sympathetic neuronal transport system in canine mechanical-overload heart failure. Metaiodobenzylguanidine [ 123 I] scintigraphy should be explored as a means of early detection of mechanical-overload heart failure in patients

  18. Mercaptosuccinic acid-coated NIR-emitting gold nanoparticles for the sensitive and selective detection of Hg2.

    Science.gov (United States)

    Xiong, Xiaodong; Lai, Xiaoqi; Liu, Jinbin

    2018-01-05

    A sensitive fluorescent detection platform for Hg 2+ was constructed based on mercaptosuccinic acid (MSA) coated near-infrared (NIR)-emitting gold nanoparticles (AuNPs). The thiolated mercaptosuccinic acid was employed as both reducing agent and surface coating ligand in a one-step synthesis of NIR-emitting AuNPs (MSA-AuNPs), which exhibited stable fluorescence with the maximum wavelength at 800nm and a wide range of excitation (220-650nm) with the maxima at 413nm. The MSA coated NIR-emitting AuNPs showed a rapid fluorescence quenching toward Hg 2+ over other metal ions with a limit of detection (LOD, 3δ) as low as 4.8nM. The sensing mechanism investigation revealed that the AuNPs formed aggregation due to the "recognition" of Hg 2+ from the MSA, and the resultant strong coupling interaction between Hg 2+ and Au (I) to further quench the fluorescence of the AuNPs, which synergistically resulted in a highly sensitive and selective fluorescence response toward Hg 2+ . This proposed strategy was also demonstrated the possibility to be used for Hg 2+ detection in water samples. Copyright © 2017. Published by Elsevier B.V.

  19. Mercaptosuccinic acid-coated NIR-emitting gold nanoparticles for the sensitive and selective detection of Hg2 +

    Science.gov (United States)

    Xiong, Xiaodong; Lai, Xiaoqi; Liu, Jinbin

    2018-01-01

    A sensitive fluorescent detection platform for Hg2 + was constructed based on mercaptosuccinic acid (MSA) coated near-infrared (NIR)-emitting gold nanoparticles (AuNPs). The thiolated mercaptosuccinic acid was employed as both reducing agent and surface coating ligand in a one-step synthesis of NIR-emitting AuNPs (MSA-AuNPs), which exhibited stable fluorescence with the maximum wavelength at 800 nm and a wide range of excitation (220-650 nm) with the maxima at 413 nm. The MSA coated NIR-emitting AuNPs showed a rapid fluorescence quenching toward Hg2 + over other metal ions with a limit of detection (LOD, 3δ) as low as 4.8 nM. The sensing mechanism investigation revealed that the AuNPs formed aggregation due to the "recognition" of Hg2 + from the MSA, and the resultant strong coupling interaction between Hg2 + and Au (I) to further quench the fluorescence of the AuNPs, which synergistically resulted in a highly sensitive and selective fluorescence response toward Hg2 +. This proposed strategy was also demonstrated the possibility to be used for Hg2 + detection in water samples.

  20. Reusable nanosilver-coated magnetic particles for ultrasensitive SERS-based detection of malachite green in water samples

    Science.gov (United States)

    Song, Dan; Yang, Rong; Wang, Chongwen; Xiao, Rui; Long, Feng

    2016-01-01

    A novel nanosilver-deposited silica-coated Fe3O4 magnetic particle (Fe3O4@SiO2@Ag) with uniform size, good SERS activity and magnetic responsiveness was synthesized using amination polymer. The Fe3O4@SiO2@Ag magnetic particles have been successfully applied for ultrasensitive SERS detection of malachite green (MG) in water samples. The mechanism is that MG can be adsorbed on the silver surface of nanosilver-coated magnetic particles via one nitrogen atom, and the Raman signal intensity of MG is significantly enhanced by the nanosilver layer formed on the magnetic particles. The developed sensing system exhibited a sensitive response to MG in the range of 10 fM to 100 μM with a low limit of detection (LOD) 2 fM under optimal conditions. The LOD was several orders of magnitude lower than those of other methods. This SERS-based sensor showed good reproducibility and stability for MG detection. The silver-coated magnetic particles could easily be regenerated as SERS substrates only using low pH solution for multiple sensing events. The recovery of MG added to several water samples at different concentrations ranged from 90% to 110%. The proposed method facilitates the ultrasensitive analysis of dyes to satisfy the high demand for ensuring the safety of water sources. PMID:26964502

  1. A geometric approach for fault detection and isolation of stator short circuit failure in a single asynchronous machine

    KAUST Repository

    Khelouat, Samir

    2012-06-01

    This paper deals with the problem of detection and isolation of stator short-circuit failure in a single asynchronous machine using a geometric approach. After recalling the basis of the geometric approach for fault detection and isolation in nonlinear systems, we will study some structural properties which are fault detectability and isolation fault filter existence. We will then design filters for residual generation. We will consider two approaches: a two-filters structure and a single filter structure, both aiming at generating residuals which are sensitive to one fault and insensitive to the other faults. Some numerical tests will be presented to illustrate the efficiency of the method.

  2. The mechanical integrity and protective performance of silica coatings

    International Nuclear Information System (INIS)

    Crouch, A.G.; Dooley, R.B.

    1976-01-01

    Silica coatings have been developed to reduce the oxidation rates of 9Cr and other steels in high temperature environments. An important aspect of their performance is their ability to withstand the mechanical and thermal strains likely to be encountered in practical applications. This has been examined. Silica-coated 9 Cr steel specimens were deformed in tension and coating failure was detected by scanning electron microscope observations of the oxide stringers which delineated the strain-induced cracks on subsequent exidation. Coating fracture was shown to occur in the strain range 0.27 to 0.45%. The crack separation at constant coating thickness decresed with strain and at constant strain was approximately proportional to the square root of the coating thickness. The implications of these results for the protection of the underlying alloy by a cracked coating are considered. (author)

  3. Analyses of performance of novel sensors with different coatings for detection of Lipopolysaccharide

    KAUST Repository

    Mohd. Syaifudin, A. R.

    2011-10-01

    Interdigital sensors have been widely used for non-destructive applications. New types of planar interdigital sensors have been fabricated with different coating materials to assess the response to Lipopolysaccharide, LPS. All the coatings were selected and optimized to be stable in water, as the measurements take place in water media. Moreover, the coatings have been designed to have available carboxylic or amine functional groups. The use of these functional groups is a widely used technique to specifically binding of biomolecules. The coated sensors were then immobilized with Polymyxin B(PmB) which has the specific binding properties to LPS. This paper will highlight the fabrication process and initial investigations on the sensors\\' performance based on Impedance Spectroscopy. © 2011 IEEE.

  4. Use of Wavelet Transform to Detect Compensated and Decompensated Stages in the Congestive Heart Failure Patient

    Directory of Open Access Journals (Sweden)

    Pratibha Sharma

    2017-09-01

    Full Text Available This research work is aimed at improving health care, reducing cost, and the occurrence of emergency hospitalization in patients with Congestive Heart Failure (CHF by analyzing heart and lung sounds to distinguish between the compensated and decompensated states. Compensated state defines stable state of the patient but with lack of retention of fluids in lungs, whereas decompensated state leads to unstable state of the patient with lots of fluid retention in the lungs, where the patient needs medication. Acoustic signals from the heart and the lung were analyzed using wavelet transforms to measure changes in the CHF patient’s status from the decompensated to compensated and vice versa. Measurements were taken on CHF patients diagnosed to be in compensated and decompensated states by using a digital stethoscope and electrocardiogram (ECG in order to monitor their progress in the management of their disease. Analysis of acoustic signals of the heart due to the opening and closing of heart valves as well as the acoustic signals of the lungs due to respiration and the ECG signals are presented. Fourier, short-time Fourier, and wavelet transforms are evaluated to determine the best method to detect shifts in the status of a CHF patient. The power spectra obtained through the Fourier transform produced results that differentiate the signals from healthy people and CHF patients, while the short-time Fourier transform (STFT technique did not provide the desired results. The most promising results were obtained by using wavelet analysis. Wavelet transforms provide better resolution, in time, for higher frequencies, and a better resolution, in frequency, for lower frequencies.

  5. Developing the surveillance algorithm for detection of failure to recognize and treat severe sepsis.

    Science.gov (United States)

    Harrison, Andrew M; Thongprayoon, Charat; Kashyap, Rahul; Chute, Christopher G; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly

    2015-02-01

    To develop and test an automated surveillance algorithm (sepsis "sniffer") for the detection of severe sepsis and monitoring failure to recognize and treat severe sepsis in a timely manner. We conducted an observational diagnostic performance study using independent derivation and validation cohorts from an electronic medical record database of the medical intensive care unit (ICU) of a tertiary referral center. All patients aged 18 years and older who were admitted to the medical ICU from January 1 through March 31, 2013 (N=587), were included. The criterion standard for severe sepsis/septic shock was manual review by 2 trained reviewers with a third superreviewer for cases of interobserver disagreement. Critical appraisal of false-positive and false-negative alerts, along with recursive data partitioning, was performed for algorithm optimization. An algorithm based on criteria for suspicion of infection, systemic inflammatory response syndrome, organ hypoperfusion and dysfunction, and shock had a sensitivity of 80% and a specificity of 96% when applied to the validation cohort. In order, low systolic blood pressure, systemic inflammatory response syndrome positivity, and suspicion of infection were determined through recursive data partitioning to be of greatest predictive value. Lastly, 117 alert-positive patients (68% of the 171 patients with severe sepsis) had a delay in recognition and treatment, defined as no lactate and central venous pressure measurement within 2 hours of the alert. The optimized sniffer accurately identified patients with severe sepsis that bedside clinicians failed to recognize and treat in a timely manner. Copyright © 2015 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  6. Extended prediction rule to optimise early detection of heart failure in older persons with non-acute shortness of breath : A cross-sectional study

    NARCIS (Netherlands)

    Van Riet, Evelien E S; Hoes, Arno W.; Limburg, Alexander; Landman, Marcel A J; Kemperman, Hans; Rutten, Frans H.

    2016-01-01

    Objectives: There is a need for a practical tool to aid general practitioners in early detection of heart failure in the elderly with shortness of breath. In this study, such a screening rule was developed based on an existing rule for detecting heart failure in older persons with a diagnosis of

  7. Highly sensitive luminescent sensor for cyanide ion detection in aqueous solution based on PEG-coated ZnS nanoparticles.

    Science.gov (United States)

    Mehta, Surinder K; Salaria, Khushboo; Umar, Ahmad

    2013-03-15

    Using polyethylene glycol (PEG) coated ZnS nanoparticles (NPs), a novel and highly sensitive luminescent sensor for cyanide ion detection in aqueous solution has been presented. ZnS NPs have been used to develop efficient luminescence sensor which exhibits high reproducibility and stability with the lowest limit of detection of 1.29×10(-6) mol L(-1). The observed limit of detection of the fabricated sensor is ~6 times lower than maximum value of cyanide permitted by United States Environmental Protection Agency for drinking water (7.69×10(-6) mol L(-1)). The interfering studies show that the developed sensor possesses good selectivity for cyanide ion even in presence of other coexisting ions. Importantly, to the best of our knowledge, this is the first report which demonstrates the utilization of PEG- coated ZnS NPs for efficient luminescence sensor for cyanide ion detection in aqueous solution. This work demonstrates that rapidly synthesized ZnS NPs can be used to fabricate efficient luminescence sensor for cyanide ion detection. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Flight Control Failure Detection and Control Redistribution Using Multiple Model Adaptive Estimation with Filter Spawning

    National Research Council Canada - National Science Library

    Torres, Michael

    2002-01-01

    ...) are used together to identify failures and apply appropriate corrections. This effort explores the performance of the MMAE/FS/CR in different regions of the flight envelope using model and gain scheduling...

  9. Ultra-low fouling and high antibody loading zwitterionic hydrogel coatings for sensing and detection in complex media.

    Science.gov (United States)

    Chou, Ying-Nien; Sun, Fang; Hung, Hsiang-Chieh; Jain, Priyesh; Sinclair, Andrew; Zhang, Peng; Bai, Tao; Chang, Yung; Wen, Ten-Chin; Yu, Qiuming; Jiang, Shaoyi

    2016-08-01

    For surface-based diagnostic devices to achieve reliable biomarker detection in complex media such as blood, preventing nonspecific protein adsorption and incorporating high loading of biorecognition elements are paramount. In this work, a novel method to produce nonfouling zwitterionic hydrogel coatings was developed to achieve these goals. Poly(carboxybetaine acrylamide) (pCBAA) hydrogel thin films (CBHTFs) prepared with a carboxybetaine diacrylamide crosslinker (CBAAX) were coated on gold and silicon dioxide surfaces via a simple spin coating process. The thickness of CBHTFs could be precisely controlled between 15 and 150nm by varying the crosslinker concentration, and the films demonstrated excellent long-term stability. Protein adsorption from undiluted human blood serum onto the CBHTFs was measured with surface plasmon resonance (SPR). Hydrogel thin films greater than 20nm exhibited ultra-low fouling (crosslinked, purely zwitterionic, carboxybetaine thin film hydrogel (CBHTF) coating platform. The CBHTF on a hydrophilic surface demonstrated long-term stability. By varying the crosslinker content in the spin-coated hydrogel solution, the thickness of CBHTFs could be precisely controlled. Optimized CBHTFs exhibited ultra-low nonspecific protein adsorption below 5ng/cm(2) measured by a surface plasmon resonance (SPR) sensor, and their 3D architecture allowed antibody loading to reach 693ng/cm(2). This strategy provides a facile method to modify SPR biosensor chips with an advanced nonfouling material, and can be potentially expanded to a variety of implantable medical devices and diagnostic biosensors. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  10. Nanofilm-coated long-period fiber grating humidity sensors for corrosion detection in structural health monitoring

    Science.gov (United States)

    Zheng, Shijie; Zhu, Yinian; Krishnaswamy, Sridhar

    2011-04-01

    Long-period gratings (LPGs) have shown their significant promising applications in sensors owing to the attractive features that they posses such as small size, immunity for electromagnetic interference, geometric versatility, multiplexing capability, and resistance to corrosive and hazardous environments. Recent researches have revealed that LPGs written on the standard optical fibers could be used as a powerful sensing platform for structural health monitoring. In this work, we inscribe LPGs into SMF-28 optical fiber by focused-beam CO2 laser, demonstrating as a refractive index sensor for nondestructive chemical detections in the civil infrastructures. Although evanescent-field based LPG sensors have been applied in quantitatively monitoring chemical analytes including moisture, chloride, and corrosion by-product, etc., the sensitivity, selectivity, and response time as well as thermo-stability of such sensors are still the issues for some special purposes. In order to improve those characteristics of the sensors, we propose two types of nano-film to be coated in grating region by electrostatic self-assembly (ESA) deposition processing. The primary coating does not affect on LPG transmission parameters such as resonance wavelength and its intensity that can be used for sensing, but it increases the sensitivity to refractive index change of surrounding material. The secondary coating is for selectively absorption of analyte molecule of interest. Response time of the nanofilm-coated LPG sensor is dependent on the analyte absorption and de-absorption rates as well as the thicknesses of the coating materials, which is also investigated. Multi-channel sensor system is being designed to monitor different analytes simultaneously, which is continuing to further explore the monitoring of structural health conditions through in situ measurements of corrosion in the concrete structures.

  11. Detection of instrument or component failures in a nuclear plant by Luenberger observers

    International Nuclear Information System (INIS)

    Wilburn, N.P.; Colley, R.W.; Alexandro, F.J.; Clark, R.N.

    1985-01-01

    A diagnostic system, which will distinguish between instrument failures (flowmeters, etc.) and component failures (valves, filters, etc.) that show the same symptoms, has been developed for nuclear Plants using Luenberger observers. Luenberger observers are online computer based modules constructed following the technology of Clark [3]. A seventh order model of an FFTF subsystem was constructed using the Advanced Continuous Simulation Language (ACSL) and was used to show through simulation that Luenberger observers can be applied to nuclear systems

  12. Amperometric biosensor based on carbon nanotubes coated with polyaniline/dendrimer-encapsulated Pt nanoparticles for glucose detection

    International Nuclear Information System (INIS)

    Xu Lihuan; Zhu Yihua; Yang Xiaoling; Li Chunzhong

    2009-01-01

    A novel amperometric glucose biosensor based on the nanocomposites of multi-wall carbon nanotubes (CNT) coated with polyaniline (PANI) and dendrimer-encapsulated Pt nanoparticles (Pt-DENs) is prepared. CNT coated with protonated PANI is in situ synthesized and Pt-DENs is absorbed on PANI/CNT composite surface by self-assembly method. Then Glucose oxidase (GOx) is crosslink-immobilizated onto Pt-DENs/PANI/CNT composite film. The results show that the fabricated GOx/Pt-DENs/PANI/CNT electrode exhibits excellent response performance to glucose, such as low detection limit (0.5 μM), wide linear range (1 μM-12 mM), short response time (about 5 s), high sensitivity (42.0 μA mM -1 cm -2 ) and stability (83% remains after 3 weeks).

  13. Detection of trace microcystin-LR on a 20 MHz QCM sensor coated with in situ self-assembled MIPs.

    Science.gov (United States)

    He, Hao; Zhou, Lianqun; Wang, Yi; Li, Chuanyu; Yao, Jia; Zhang, Wei; Zhang, Qingwen; Li, Mingyu; Li, Haiwen; Dong, Wen-fei

    2015-01-01

    A 20 MHz quartz crystal microbalance (QCM) sensor coated with in situ self-assembled molecularly imprinted polymers (MIPs) was presented for the detection of trace microcystin-LR (MC-LR) in drinking water. The sensor performance obtained using the in situ self-assembled MIPs was compared with traditionally synthesized MIPs on 20 MHz and normal 10 MHz QCM chip. The results show that the response increases by more than 60% when using the in situ self-assembly method compared using the traditionally method while the 20 MHz QCM chip provides four-fold higher response than the 10 MHz one. Therefore, the in situ self-assembled MIPs coated on a high frequency QCM chip was used in the sensor performance test to detect MC-LR in tap water. It showed a limit of detection (LOD) of 0.04 nM which is lower than the safety guideline level (1 nM MC-LR) of drinking water in China. The low sensor response to other analogs indicated the high specificity of the sensor to MC-LR. The sensor showed high stability and low signal variation less than 2.58% after regeneration. The lake water sample analysis shows the sensor is possible for practical use. The combination of the higher frequency QCM with the in situ self-assembled MIPs provides a good candidate for the detection of other small molecules. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Zucchini yellow mosaic virus: biological properties, detection procedures and comparison of coat protein gene sequences.

    Science.gov (United States)

    Coutts, B A; Kehoe, M A; Webster, C G; Wylie, S J; Jones, R A C

    2011-12-01

    Between 2006 and 2010, 5324 samples from at least 34 weed, two cultivated legume and 11 native species were collected from three cucurbit-growing areas in tropical or subtropical Western Australia. Two new alternative hosts of zucchini yellow mosaic virus (ZYMV) were identified, the Australian native cucurbit Cucumis maderaspatanus, and the naturalised legume species Rhyncosia minima. Low-level (0.7%) seed transmission of ZYMV was found in seedlings grown from seed collected from zucchini (Cucurbita pepo) fruit infected with isolate Cvn-1. Seed transmission was absent in >9500 pumpkin (C. maxima and C. moschata) seedlings from fruit infected with isolate Knx-1. Leaf samples from symptomatic cucurbit plants collected from fields in five cucurbit-growing areas in four Australian states were tested for the presence of ZYMV. When 42 complete coat protein (CP) nucleotide (nt) sequences from the new ZYMV isolates obtained were compared to those of 101 complete CP nt sequences from five other continents, phylogenetic analysis of the 143 ZYMV sequences revealed three distinct groups (A, B and C), with four subgroups in A (I-IV) and two in B (I-II). The new Australian sequences grouped according to collection location, fitting within A-I, A-II and B-II. The 16 new sequences from one isolated location in tropical northern Western Australia all grouped into subgroup B-II, which contained no other isolates. In contrast, the three sequences from the Northern Territory fitted into A-II with 94.6-99.0% nt identities with isolates from the United States, Iran, China and Japan. The 23 new sequences from the central west coast and two east coast locations all fitted into A-I, with 95.9-98.9% nt identities to sequences from Europe and Japan. These findings suggest that (i) there have been at least three separate ZYMV introductions into Australia and (ii) there are few changes to local isolate CP sequences following their establishment in remote growing areas. Isolates from A-I and B

  15. A multivariate statistical methodology for detection of degradation and failure trends using nuclear power plant operational data

    International Nuclear Information System (INIS)

    Samanta, P.K.; Teichmann, T.

    1990-01-01

    In this paper, a multivariate statistical method is presented and demonstrated as a means for analyzing nuclear power plant transients (or events) and safety system performance for detection of malfunctions and degradations within the course of the event based on operational data. The study provides the methodology and illustrative examples based on data gathered from simulation of nuclear power plant transients (due to lack of easily accessible operational data). Such an approach, once fully developed, can be used to detect failure trends and patterns and so can lead to prevention of conditions with serious safety implications

  16. Hybrid Photonic Cavity with Metal-Organic Framework Coatings for the Ultra-Sensitive Detection of Volatile Organic Compounds with High Immunity to Humidity

    Science.gov (United States)

    Tao, Jifang; Wang, Xuerui; Sun, Tao; Cai, Hong; Wang, Yuxiang; Lin, Tong; Fu, Dongliang; Ting, Lennon Lee Yao; Gu, Yuandong; Zhao, Dan

    2017-01-01

    Detection of volatile organic compounds (VOCs) at parts-per-billion (ppb) level is one of the most challenging tasks for miniature gas sensors because of the high requirement on sensitivity and the possible interference from moisture. Herein, for the first time, we present a novel platform based on a hybrid photonic cavity with metal-organic framework (MOF) coatings for VOCs detection. We have fabricated a compact gas sensor with detection limitation ranging from 29 to 99 ppb for various VOCs including styrene, toluene, benzene, propylene and methanol. Compared to the photonic cavity without coating, the MOF-coated solution exhibits a sensitivity enhancement factor up to 1000. The present results have demonstrated great potential of MOF-coated photonic resonators in miniaturized gas sensing applications.

  17. A method for reduction of Acoustic Emission (AE) data with application in machine failure detection and diagnosis

    Science.gov (United States)

    Vicuña, Cristián Molina; Höweler, Christoph

    2017-12-01

    The use of AE in machine failure diagnosis has increased over the last years. Most AE-based failure diagnosis strategies use digital signal processing and thus require the sampling of AE signals. High sampling rates are required for this purpose (e.g. 2 MHz or higher), leading to streams of large amounts of data. This situation is aggravated if fine resolution and/or multiple sensors are required. These facts combine to produce bulky data, typically in the range of GBytes, for which sufficient storage space and efficient signal processing algorithms are required. This situation probably explains why, in practice, AE-based methods consist mostly in the calculation of scalar quantities such as RMS and Kurtosis, and the analysis of their evolution in time. While the scalar-based approach offers the advantage of maximum data reduction; it has the disadvantage that most part of the information contained in the raw AE signal is lost unrecoverably. This work presents a method offering large data reduction, while keeping the most important information conveyed by the raw AE signal, useful for failure detection and diagnosis. The proposed method consist in the construction of a synthetic, unevenly sampled signal which envelopes the AE bursts present on the raw AE signal in a triangular shape. The constructed signal - which we call TriSignal - also permits the estimation of most scalar quantities typically used for failure detection. But more importantly, it contains the information of the time of occurrence of the bursts, which is key for failure diagnosis. Lomb-Scargle normalized periodogram is used to construct the TriSignal spectrum, which reveals the frequency content of the TriSignal and provides the same information as the classic AE envelope. The paper includes application examples in planetary gearbox and low-speed rolling element bearing.

  18. An in-situ infection detection sensor coating for urinary catheters.

    Science.gov (United States)

    Milo, Scarlet; Thet, Naing Tun; Liu, Dan; Nzakizwanayo, Jonathan; Jones, Brian V; Jenkins, A Toby A

    2016-07-15

    We describe a novel infection-responsive coating for urinary catheters that provides a clear visual early warning of Proteus mirabilis infection and subsequent blockage. The crystalline biofilms of P. mirabilis can cause serious complications for patients undergoing long-term bladder catheterisation. Healthy urine is around pH 6, bacterial urease increases urine pH leading to the precipitation of calcium and magnesium deposits from the urine, resulting in dense crystalline biofilms on the catheter surface that blocks urine flow. The coating is a dual layered system in which the lower poly(vinyl alcohol) layer contains the self-quenching dye carboxyfluorescein. This is capped by an upper layer of the pH responsive polymer poly(methyl methacrylate-co-methacrylic acid) (Eudragit S100®). Elevation of urinary pH (>pH 7) dissolves the Eudragit layer, releasing the dye to provide a clear visual warning of impending blockage. Evaluation of prototype coatings using a clinically relevant in vitro bladder model system demonstrated that coatings provide up to 12h advanced warning of blockage, and are stable both in the absence of infection, and in the presence of species that do not cause catheter blockage. At the present time, there are no effective methods to control these infections or provide warning of impending catheter blockage. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Detection of mechanical failures in induction motors by current spectrum analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sokansky, K; Novak, P; Bilos, J; Labaj, J [Technical University Ostrava, Moraviasilesian Power Stations s.h.c. (Czech Republic)

    1998-12-31

    From the diagnostic point of view, an electric machine can be understood as an electromechanical system. It means that any manifestations of mechanical failures do not have to show themselves only in mechanical quantities, i.e. vibration in our case. Mechanical failures can also manifest themselves in electrical quantities, namely in electric current in our case. This statement is valid inversely too, which means that faults occurring in electric circuits can be measured through mechanical quantities. This presentation deals with measuring the current spectra of induction motors with short circuited armatures that are drives used in the industries most. (orig.) 3 refs.

  20. Detection of mechanical failures in induction motors by current spectrum analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sokansky, K.; Novak, P.; Bilos, J.; Labaj, J. [Technical University Ostrava, Moraviasilesian Power Stations s.h.c. (Czech Republic)

    1997-12-31

    From the diagnostic point of view, an electric machine can be understood as an electromechanical system. It means that any manifestations of mechanical failures do not have to show themselves only in mechanical quantities, i.e. vibration in our case. Mechanical failures can also manifest themselves in electrical quantities, namely in electric current in our case. This statement is valid inversely too, which means that faults occurring in electric circuits can be measured through mechanical quantities. This presentation deals with measuring the current spectra of induction motors with short circuited armatures that are drives used in the industries most. (orig.) 3 refs.

  1. Rapid, enhanced detection of Salmonella Typhimurium on fresh spinach leaves using micron-scale, phage-coated magnetoelastic biosensors

    Science.gov (United States)

    Horikawa, Shin; Vaglenov, Kiril A.; Gerken, Dana M.; Chai, Yating; Park, Mi-Kyung; Li, Suiqiong; Petrenko, Valery A.; Chin, Bryan A.

    2012-05-01

    In order to cost-effectively and rapidly detect bacterial food contamination in the field, the potential usefulness of phage-coated magnetoelastic (ME) biosensors has been recently reported. These biosensors are freestanding, mass-sensitive biosensors that can be easily batch-fabricated, thereby reducing the fabrication cost per sensor to a fraction of a cent. In addition, the biosensors can be directly placed on fresh produce surfaces and used to rapidly monitor possible bacterial food contamination without any preceding sample preparation. Previous investigations showed that the limit of detection (LOD) with millimeter-scale ME biosensors was fairly low for fresh produce with smooth surfaces (e.g., tomatoes and shell eggs). However, the LOD is anticipated to be dependent on the size of the biosensors as well as the topography of produce surfaces of interest. This paper presents an investigation into the use of micron-scale, phage-coated ME biosensors for the enhanced detection of Salmonella Typhimurium on fresh spinach leaves.

  2. Fast neutron reactor noise analysis: beginning failure detection and physical parameter estimation

    International Nuclear Information System (INIS)

    Le Guillou, G.

    1975-01-01

    The analysis of the signals fluctuations coming from a power nuclear reactor (a breeder), by correlation methods and spectral analysis has two principal applications: on line estimation of physical parameters (reactivity coefficients); beginning failures (little boiling, abnormal mechanic vibrations). These two applications give important informations to the reactor core control and permit a good diagnosis [fr

  3. Shoreline Erosion and Slope Failure Detection over Southwest Lakeshore Michigan using Temporal Radar and Digital Elevation Model

    Science.gov (United States)

    Sataer, G.; Sultan, M.; Yellich, J. A.; Becker, R.; Emil, M. K.; Palaseanu, M.

    2017-12-01

    Throughout the 20th century and into the 21st century, significant losses of residential, commercial and governmental property were reported along the shores of the Great Lakes region due to one or more of the following factors: high lake levels, wave actions, groundwater discharge. A collaborative effort (Western Michigan University, University of Toledo, Michigan Geological Survey [MGS], United States Geological Survey [USGS], National Oceanographic and Atmospheric Administration [NOAA]) is underway to examine the temporal topographic variations along the shoreline and the adjacent bluff extending from the City of South Haven in the south to the City of Saugatuck in the north within the Allegan County. Our objectives include two main tasks: (1) identification of the timing of, and the areas, witnessing slope failure and shoreline erosion, and (2) investigating the factors causing the observed failures and erosion. This is being accomplished over the study area by: (1) detecting and measuring slope subsidence rates (velocities along line of site) and failures using radar interferometric persistent scatter (PS) techniques applied to ESA's European Remote Sensing (ERS) satellites, ERS-1 and -2 (spatial resolution: 25 m) that were acquired in 1995 to 2007, (2) extracting temporal high resolution (20 cm) digital elevation models (DEM) for the study area from temporal imagery acquired by Unmanned Aerial Vehicles (UAVs), and applying change detection techniques to the extracted DEMs, (3) detecting change in elevation and slope profiles extracted from two LIDAR Coastal National Elevation Database (CoNED) DEMs (spatial resolution: 0.5m), acquired on 2008 and 2012, and (4) spatial and temporal correlation of the detected changes in elevation with relevant data sets (e.g., lake levels, precipitation, groundwater levels) in search of causal effects.

  4. Evaluation of the cool-down behaviour of ITER FW beryllium tiles for an early failure detection

    Directory of Open Access Journals (Sweden)

    Thomas Weber

    2016-12-01

    Full Text Available The design of the first wall in ITER foresees several hundred thousand beryllium tiles, which are bonded to the water-cooled CuCrZr supporting structure. Due to the nature of a Tokamak reactor this bonding is faced to thermal fatigue. Since the failure of a single tile might already have a major impact on the operability of ITER, comprehensive high heat flux tests are performed on prototypes prior to the acceptance of manufacturing procedures. For a deeper understanding of the temperature curves, which were and will be measured by IR devices of these first wall prototypes, thermo-mechanical FEM simulations shall demonstrate the possibilities of an early bonding failure detection. Hereby, the maximum temperatures for each cycle as well as the cool-down behaviour are the input data.

  5. Ultra-Sensitive NT-proBNP Quantification for Early Detection of Risk Factors Leading to Heart Failure

    Directory of Open Access Journals (Sweden)

    Keum-Soo Song

    2017-09-01

    Full Text Available Cardiovascular diseases such as acute myocardial infarction and heart failure accounted for the death of 17.5 million people (31% of all global deaths in 2015. Monitoring the level of circulating N-terminal proBNP (NT-proBNP is crucial for the detection of people at risk of heart failure. In this article, we describe a novel ultra-sensitive NT-proBNP test (us-NT-proBNP that allows the quantification of circulating NT-proBNP in 30 min at 25 °C in the linear detection range of 7.0–600 pg/mL. It is a first report on the application of a fluorescence bead labeled detection antibody, DNA-guided detection method, and glass fiber membrane platform for the quantification of NT-proBNP in clinical samples. Limit of blank, limit of detection, and limit of quantification were 2.0 pg/mL, 3.7 pg/mL, and 7 pg/mL, respectively. The coefficient of variation was found to be less than 10% in the entire detection range of 7–600 pg/mL. The test demonstrated specificity for NT-proBNP without interferences from bilirubin, intra-lipid, biotin, and hemoglobin. The serial dilution test for plasma samples containing various NT-proBNP levels showed the linear decrement in concentration with the regression coefficient of 0.980–0.998. These results indicate that us-NT-proBNP test does not suffer from the interference of the plasma components for the measurement of NT-proBNP in clinical samples.

  6. Cerebral metabolic abnormalities in congestive heart failure detected by proton magnetic resonance spectroscopy.

    Science.gov (United States)

    Lee, C W; Lee, J H; Kim, J J; Park, S W; Hong, M K; Kim, S T; Lim, T H; Park, S J

    1999-04-01

    Using proton magnetic resonance spectroscopy, we investigated cerebral metabolism and its determinants in congestive heart failure (CHF), and the effects of cardiac transplantation on these measurements. Few data are available about cerebral metabolism in CHF. Fifty patients with CHF (ejection fraction OGM) and parietal white matter (PWM). Absolute levels of the metabolites (N-acetylaspartate, creatine, choline, myo-inositol) were calculated. In PWM only creatine level was significantly lower in CHF than in control subjects, but in OGM all four metabolite levels were decreased in CHF. The creatine level was independently correlated with half-recovery time and duration of heart failure symptoms in PWM (r = -0.56, p OGM (r = 0.58, p < 0.05). Cerebral metabolic abnormalities were improved after successful cardiac transplantation. This study shows that cerebral metabolism is abnormally deranged in advanced CHF and it may serve as a potential marker of the disease severity.

  7. Lifetime Fluorescence and Raman Imaging for Detection of Wound Failure and Heterotopic Ossification

    Science.gov (United States)

    2015-12-01

    December 2015 TYPE OF REPORT: Final PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012...valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE December 2015 2. REPORT TYPE Final 3. DATES COVERED...failure facilitates increased risk of infection and can lead to permanent disabilities or death. Current treatment methods include regular debridement

  8. Rapid detection of malachite green in fish based on CdTe quantum dots coated with molecularly imprinted silica.

    Science.gov (United States)

    Wu, Le; Lin, Zheng-Zhong; Zhong, Hui-Ping; Peng, Ai-Hong; Chen, Xiao-Mei; Huang, Zhi-Yong

    2017-08-15

    A sensitive fluorescence sensor for the detection of malachite green (MG) was fabricated by grafting molecularly imprinted polymers (MIPs) onto the surface of CdTe quantum dots (QDs). The MIP-coated QDs were synthesized via a reverse microemulsion method using (3-aminopropyl)triethoxysilane (APTES) and tetraethyl orthosilicate (TEOS) as functional monomer and cross-linker, respectively. The optimum molar ratio of MG, functional monomer and cross-linker was 1:3:10. The MIP-coated QDs exhibited uniform spheres with diameter around 49nm and excellent fluorescence emission at λ ex 370nm. A linear relationship with two segments between the relative fluorescence intensities and the MG concentrations ranging from 0.08 to 20μmol·L -1 could be obtained with a detection limit of 12μg·kg -1 . The fluorescent probe was successfully applied to the determination of MG in fish samples with the spiked recoveries ranging from 94.3% to 109.5% which were in accordance with those of the measurement by HPLC-UV. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Response Characterization of a Fiber Optic Sensor Array with Dye-Coated Planar Waveguide for Detection of Volatile Organic Compounds

    Directory of Open Access Journals (Sweden)

    Jae-Sung Lee

    2014-07-01

    Full Text Available We have developed a multi-array side-polished optical-fiber gas sensor for the detection of volatile organic compound (VOC gases. The side-polished optical-fiber coupled with a polymer planar waveguide (PWG provides high sensitivity to alterations in refractive index. The PWG was fabricated by coating a solvatochromic dye with poly(vinylpyrrolidone. To confirm the effectiveness of the sensor, five different sensing membranes were fabricated by coating the side-polished optical-fiber using the solvatochromic dyes Reinhardt’s dye, Nile red, 4-aminophthalimide, 4-amino-N-methylphthalimide, and 4-(dimethylaminocinnamaldehyde, which have different polarities that cause changes in the effective refractive index of the sensing membrane owing to evanescent field coupling. The fabricated gas detection system was tested with five types of VOC gases, namely acetic acid, benzene, dimethylamine, ethanol, and toluene at concentrations of 1, 2,…,10 ppb. Second-regression and principal component analyses showed that the response properties of the proposed VOC gas sensor were linearly shifted bathochromically, and each gas showed different response characteristics.

  10. Failure detection of liquid cooled electronics in sealed packages. [in airborne information management system

    Science.gov (United States)

    Hoadley, A. W.; Porter, A. J.

    1991-01-01

    The theory and experimental verification of a method of detecting fluid-mass loss, expansion-chamber pressure loss, or excessive vapor build-up in NASA's Airborne Information Management System (AIMS) are presented. The primary purpose of this leak-detection method is to detect the fluid-mass loss before the volume of vapor on the liquid side causes a temperature-critical part to be out of the liquid. The method detects the initial leak after the first 2.5 pct of the liquid mass has been lost, and it can be used for detecting subsequent situations including the leaking of air into the liquid chamber and the subsequent vapor build-up.

  11. Possibilities And Influencing Parameters For The Early Detection Of Sheet Metal Failure In Press Shop Operations

    International Nuclear Information System (INIS)

    Gerlach, Joerg; Kessler, Lutz; Paul, Udo; Roesen, Hartwig

    2007-01-01

    The concept of forming limit curves (FLC) is widely used in industrial practice. The required data should be delivered for typical material properties (measured on coils with properties in a range of +/- of the standard deviation from the mean production values) by the material suppliers. In particular it should be noted that its use for the validation of forming robustness providing forming limit curves for the variety of scattering in the mechanical properties is impossible. Therefore a forecast of the expected limit strains without expensive cost and time-consuming experiments is necessary. In the paper the quality of a regression analysis for determining forming limit curves based on tensile test results is presented and discussed.Owing to the specific definition of limit strains with FLCs following linear strain paths, the significance of this failure definition is limited. To consider nonlinear strain path effects, different methods are given in literature. One simple method is the concept of limit stresses. It should be noted that the determined value of the critical stress is dependent on the extrapolation of the tensile test curve. When the yield curve extrapolation is very similar to an exponential function, the definition of the critical stress value is very complicated due to the low slope of the hardening function at large strains.A new method to determine general failure behavior in sheet metal forming is the common use and interpretation of three criteria: onset on material instability (comparable with FLC concept), value of critical shear fracture and the value of ductile fracture. This method seems to be particularly successful for newly developed high strength steel grades in connection with more complex strain paths for some specific material elements. Nevertheless the identification of the different failure material parameters or functions will increase and the user has to learn with the interpretation of the numerical results

  12. Signal detection theory, the exclusion failure paradigm and weak consciousness--evidence for the access/phenomenal distinction?

    Science.gov (United States)

    Irvine, Elizabeth

    2009-06-01

    Block [Block, N. (2005). Two neural correlates of consciousness. Trends in Cognitive Science, 9, 46-52] and Snodgrass (2006) claim that a signal detection theory (SDT) analysis of qualitative difference paradigms, in particular the exclusion failure paradigm, reveals cases of phenomenal consciousness without access consciousness. This claim is unwarranted on several grounds. First, partial cognitive access rather than a total lack of cognitive access can account for exclusion failure results. Second, Snodgrass's Objective Threshold/Strategic (OT/S) model of perception relies on a problematic 'enable' approach to perception that denies the possibility of intentional control of unconscious perception and any effect of following different task instructions on the presence/absence of phenomenal consciousness. Many of Block's purported examples of phenomenal consciousness without cognitive access also rely on this problematic approach. Third, qualitative difference paradigms may index only a subset of access consciousness. Thus, qualitative difference paradigms like exclusion failure cannot be used to isolate phenomenal consciousness, any attempt to do so still faces serious methodological problems.

  13. Detection of pitch failures in wind turbines using environmental noise recognition techniques

    DEFF Research Database (Denmark)

    Skrimpas, Georgios Alexandros; Marhadi, Kun S.; Gomez, Robert

    2015-01-01

    Modern wind turbines employ pitch regulated control strategies in order to optimise the yielded power production. Pitch systems can be subjected to various failure modes related to cylinders, bearings and loose mounting, leading to poor pitching and aerodynamic imbalance. Early stage pitch....... The proposed method is built upon the following three processes. Firstly, the impacts are identified using envelope analysis, followed by the extraction of 12 features, such as energy, crest factor and peak to peak amplitude and finally the classification of the events based on the above features. Eighty nine...

  14. The detection of organic solvent vapor by using polymer coated chemocapacitor sensor

    Science.gov (United States)

    Rusdiarna Indrapraja, Apik; Rivai, Muhammad; Arifin, Achmad; Purwanto, Djoko

    2017-05-01

    A chemocapacitor consists of planar interdigital electrodes (IDE) made by two comb electrodes on a substrate. A dielectric film was applied on the electrodes in which the absorbed vapor will modify its permittivity. This study has fabricated chemocapacitor with the IDE distance of 0.5 mm, while the dielectric film was a sensitive layer consisting of a polymeric material. The deposition of the polymeric film was accomplished by drop casting. A sensor array consisting of four chemocapacitors coated with different polymers namely PEG-1540, PEG-20M, PEG-6000, and PVP was used to obtain the pattern of shift in the capacitance. The integrated circuit AD7746 was used as the capacitance to-digital converter (CDC). The organic solvents of ethanol, benzene, and aceton were used as the vapor samples in this experiment. The results showed that the change in the capacitance value increases proportionally to the concentration of vapour where sensors coated with PEG-1540 and PVP have higher sensitivity, i.e. 0.0028pF/part per thousand and 0.0027pF/part per thousand, respectively. Based on the capacitance to digital conversion capabilities, the system provides there solution of 0.4084ppm. The sensor array could produce a different pattern for each of the vapor sample. The Neural Network pattern recognition system could identify the type of vapor automatically with the root mean square error of 10-5

  15. The importance of scaling for detecting community patterns: success and failure in assemblages of introduced species

    Science.gov (United States)

    Allen, Craig R.; Angeler, David G.; Moulton, Michael P.; Holling, Crawford S.

    2015-01-01

    Community saturation can help to explain why biological invasions fail. However, previous research has documented inconsistent relationships between failed invasions (i.e., an invasive species colonizes but goes extinct) and the number of species present in the invaded community. We use data from bird communities of the Hawaiian island of Oahu, which supports a community of 38 successfully established introduced birds and where 37 species were introduced but went extinct (failed invasions). We develop a modified approach to evaluate the effects of community saturation on invasion failure. Our method accounts (1) for the number of species present (NSP) when the species goes extinct rather than during its introduction; and (2) scaling patterns in bird body mass distributions that accounts for the hierarchical organization of ecosystems and the fact that interaction strength amongst species varies with scale. We found that when using NSP at the time of extinction, NSP was higher for failed introductions as compared to successful introductions, supporting the idea that increasing species richness and putative community saturation mediate invasion resistance. Accounting for scale-specific patterns in body size distributions further improved the relationship between NSP and introduction failure. Results show that a better understanding of invasion outcomes can be obtained when scale-specific community structure is accounted for in the analysis.

  16. An ultrasensitive chemiluminescence immunoassay for fumonisin B1 detection in cereals based on gold-coated magnetic nanoparticles.

    Science.gov (United States)

    Jie, Mingsha; Yu, Songcheng; Yu, Fei; Liu, Lie; He, Leiliang; Li, Yanqiang; Zhang, Hongquan; Qu, Lingbo; Harrington, Peter de B; Wu, Yongjun

    2018-07-01

    In the present study, a novel highly sensitive magnetic enzyme chemiluminescence immunoassay (MECLIA) was developed to detect fumonisin B 1 (FB 1 ) in cereal samples. The gold-coated magnetic nanoparticles (Fe 3 O 4 @Au, GoldMag) were used as solid phase carrier to develop a competitive CLIA for detecting FB 1 , in which FB 1 in samples would compete with FB 1 -ovalbumin coated on the surface of Fe 3 O 4 @Au nanoparticles for binding with FB 1 antibodies. Successively, horseradish peroxidase labeled goat anti-rabbit IgG (HRP-IgG) was conjugated with FB 1 antibodies on the microplate. In substrate solution containing luminol and H 2 O 2 , HRP-IgG catalyzed luminol oxidation by H 2 O 2 , generating a high chemiluminescence signal. The FB 1 immune GoldMag particles were characterized by Fourier transform infrared spectroscopy, scanning electron microscope and zeta potential analysis, etc. RESULTS: The concentrations and the reaction times of these immunoreagents were optimized to improve the performances of this method. The established method could detect as low as 0.027 ng mL -1 FB 1 from 0.05 ng mL -1 to 25 ng mL -1 , demonstrating little cross-reaction (less than 2.4%) with other structurally related compounds. The average intrassay relative SD (RSD) (n = 6) was 3.4% and the average interassay RSD (n = 6) was 5.4%. This method was successfully applied for the determination of FB 1 in corn and wheat and gave recoveries of between 98-110% and 91-105%, respectively. The results of the present study suggest that the MECLIA approach has potential application for high-throughput fumonisin screening in cereals. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  17. Comparison of different modelling approaches of drive train temperature for the purposes of wind turbine failure detection

    Science.gov (United States)

    Tautz-Weinert, J.; Watson, S. J.

    2016-09-01

    Effective condition monitoring techniques for wind turbines are needed to improve maintenance processes and reduce operational costs. Normal behaviour modelling of temperatures with information from other sensors can help to detect wear processes in drive trains. In a case study, modelling of bearing and generator temperatures is investigated with operational data from the SCADA systems of more than 100 turbines. The focus is here on automated training and testing on a farm level to enable an on-line system, which will detect failures without human interpretation. Modelling based on linear combinations, artificial neural networks, adaptive neuro-fuzzy inference systems, support vector machines and Gaussian process regression is compared. The selection of suitable modelling inputs is discussed with cross-correlation analyses and a sensitivity study, which reveals that the investigated modelling techniques react in different ways to an increased number of inputs. The case study highlights advantages of modelling with linear combinations and artificial neural networks in a feedforward configuration.

  18. Preventive detection of incipient failure and improvement of availability of French PWR using acoustic emission

    International Nuclear Information System (INIS)

    Audenard, B.; Marini, J.

    1982-08-01

    Laboratory tests, on site experience gained on PWR during start up test as well as during nominal functioning have given FRAMATOME very great confidence in A.E. techniques for preventive detection of incidents. Loose part and leakage monitoring are already being used on an industrial basis. Crack growth detection and monitoring are still in the investigation phase and various. Research and Development programs are presently being carried out

  19. A Novel Thermal-Mechanical Detection System for Reactor Pressure Vessel Bottom Failure Monitoring in Severe Accidents

    International Nuclear Information System (INIS)

    Bi, Daowei; Bu, Jiangtao; Xu, Dongling

    2013-06-01

    Following the Fukushima Daiichi nuclear accident in Japan, there is an increased need of enhanced capabilities for severe accident management (SAM) program. Among others, a reliable method for detecting reactor pressure vessel (RPV) bottom failure has been evaluated as imperative by many utility owners. Though radiation and/or temperature measurement are potential solutions by tradition, there are some limitations for them to function desirably in such severe accident as that in Japan. To provide reliable information for assessment of accident progress in SAM program, in this paper we propose a novel thermal-mechanical detection system (TMDS) for RPV bottom failure monitoring in severe accidents. The main components of TMDS include thermally sensitive element, metallic cables, tension controlled switch and main control room annunciation device. With TMDS installed, there shall be a reliable means of keeping SAM decision-makers informed whether the RPV bottom has indeed failed. Such assurance definitely guarantees enhancement of severe accident management performance and significantly improve nuclear safety and thus protect the society and people. (authors)

  20. Robust Fiber Coatings

    National Research Council Canada - National Science Library

    Goettler, Richard

    2002-01-01

    The highly desired ceramic matrix composite is the one in which the high strength and strain-to-failure is achieved through judicious selection of a fiber coating that can survive the high-temperature...

  1. A novel C-shaped, gold nanoparticle coated, embedded polymer waveguide for localized surface plasmon resonance based detection.

    Science.gov (United States)

    Prabhakar, Amit; Mukherji, Soumyo

    2010-12-21

    In this study, a novel embedded optical waveguide based sensor which utilizes localized surface plasmon resonance of gold nanoparticles coated on a C-shaped polymer waveguide is being reported. The sensor, as designed, can be used as an analysis chip for detection of minor variations in the refractive index of its microenvironment, which makes it suitable for wide scale use as an affinity biosensor. The C-shaped waveguide coupled with microfluidic channel was fabricated by single step patterning of SU8 on an oxidized silicon wafer. The absorbance due to the localized surface plasmon resonance (LSPR) of SU8 waveguide bound gold nano particle (GNP) was found to be linear with refractive index changes between 1.33 and 1.37. A GNP coated C-bent waveguide of 200 μ width with a bend radius of 1 mm gave rise to a sensitivity of ~5 ΔA/RIU at 530 nm as compared to the ~2.5 ΔA/RIU (refractive index units) of the same dimension bare C-bend SU8 waveguide. The resolution of the sensor probe was ~2 × 10(-4) RIU.

  2. A NEW APPROACH TO DETECT CONGESTIVE HEART FAILURE USING DETRENDED FLUCTUATION ANALYSIS OF ELECTROCARDIOGRAM SIGNALS

    Directory of Open Access Journals (Sweden)

    CHANDRAKAR KAMATH

    2015-02-01

    Full Text Available The aim of this study is to evaluate how far the detrended fluctuation analysis (DFA approach helps to characterize the short-term and intermediate-term fractal correlations in the raw electrocardiogram (ECG signals and thereby discriminate between normal and congestive heart failure (CHF subjects. The DFA-1 calculations were performed on normal and CHF short-term ECG segments, of the order of 20 seconds duration. Differences were found in shortterm and intermediate-term correlation properties and the corresponding scaling exponents of the two groups (normal and CHF. The statistical analyses show that short-term fractal scaling exponent alone is sufficient to distinguish between normal and CHF subjects. The receiver operating characteristic curve (ROC analysis confirms the robustness of this new approach and exhibits an average accuracy that exceeds 98.2%, average sensitivity of about 98.4%, positive predictivity of 98.00%, and average specificity of 98.00%.

  3. Sensitive coating for water vapors detection based on thermally sputtered calcein thin films.

    Science.gov (United States)

    Kruglenko, I; Shirshov, Yu; Burlachenko, J; Savchenko, A; Kravchenko, S; Manera, M G; Rella, R

    2010-09-15

    In this paper the adsorption properties of thermally sputtered calcein thin films towards water and other polar molecules vapors are studied by different characterization techniques: quartz crystal microbalance, surface plasmon resonance and visible spectroscopy. Sensitivity of calcein thin films to water vapors resulted much higher as compared with those of a number of dyes whose structure was close to that of calcein. All types of sensors with calcein coatings have demonstrated linear concentration dependences in the wide range of water vapor pressure from low concentrations up to 27,000 ppm (close to saturation). At higher concentrations of water vapor all sensors demonstrate the abrupt increase of the response (up to two orders). A theoretical model is advanced explaining the adsorption properties of calcein thin films taking into account their chemical structure and peculiarities of molecular packing. The possibility of application of thermally sputtered calcein films in sensing technique is discussed. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  4. Computer simulation and SERR detection of cytochrome c dynamics at SAM-coated electrodes

    International Nuclear Information System (INIS)

    Paggi, Damian Alvarez; Martin, Diego F.; Kranich, Anja; Hildebrandt, Peter; Marti, Marcelo A.; Murgida, Daniel H.

    2009-01-01

    In this paper we present a combined experimental and theoretical study of the heterogeneous electron transfer reaction of cytochrome c electrostatically adsorbed on metal electrodes coated with monolayers of 6-mercaptohexanoic acid. Molecular dynamics simulations and pathways calculations show that adsorption of the protein leads to a broad distribution of orientations and, thus, to a correspondingly broad distribution of electron transfer rate constants due to the orientation-dependence of the electronic coupling parameter. The adsorbed protein exhibits significant mobility and, therefore, the measured reaction rate is predicted to be a convolution of protein dynamics and tunnelling probabilities for each orientation. This prediction is confirmed by time-resolved surface enhanced resonance Raman which allows for the direct monitoring of protein (re-)orientation and electron transfer of the immobilised cytochrome c. The results provide a consistent explanation for the non-exponential distance-independence of electron transfer rates usually observed for proteins immobilized on electrodes.

  5. Computer simulation and SERR detection of cytochrome c dynamics at SAM-coated electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Paggi, Damian Alvarez; Martin, Diego F. [Departamento de Quimica Inorganica, Analitica y Quimica Fisica/INQUIMAE-CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Ciudad Universitaria, Pab. 2, piso 1, C1428EHA Buenos Aires (Argentina); Kranich, Anja; Hildebrandt, Peter [Institut fuer Chemie, Technische Universitaet Berlin, Str. des 17, Juni 135, Sekr. PC14, D-10623 Berlin (Germany); Marti, Marcelo A. [Departamento de Quimica Inorganica, Analitica y Quimica Fisica/INQUIMAE-CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Ciudad Universitaria, Pab. 2, piso 1, C1428EHA Buenos Aires (Argentina)], E-mail: marcelo@qi.fcen.uba.ar; Murgida, Daniel H. [Departamento de Quimica Inorganica, Analitica y Quimica Fisica/INQUIMAE-CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Ciudad Universitaria, Pab. 2, piso 1, C1428EHA Buenos Aires (Argentina)], E-mail: dhmurgida@qi.fcen.uba.ar

    2009-09-01

    In this paper we present a combined experimental and theoretical study of the heterogeneous electron transfer reaction of cytochrome c electrostatically adsorbed on metal electrodes coated with monolayers of 6-mercaptohexanoic acid. Molecular dynamics simulations and pathways calculations show that adsorption of the protein leads to a broad distribution of orientations and, thus, to a correspondingly broad distribution of electron transfer rate constants due to the orientation-dependence of the electronic coupling parameter. The adsorbed protein exhibits significant mobility and, therefore, the measured reaction rate is predicted to be a convolution of protein dynamics and tunnelling probabilities for each orientation. This prediction is confirmed by time-resolved surface enhanced resonance Raman which allows for the direct monitoring of protein (re-)orientation and electron transfer of the immobilised cytochrome c. The results provide a consistent explanation for the non-exponential distance-independence of electron transfer rates usually observed for proteins immobilized on electrodes.

  6. Sensitive detection of plastic explosives with self-assembled monolayer-coated microcantilevers

    Science.gov (United States)

    Pinnaduwage, L. A.; Boiadjiev, V.; Hawk, J. E.; Thundat, T.

    2003-08-01

    We report the detection of 10-30 parts-per-trillion levels of pentaerythritol tetranitrate and hexahydro-1,3,5-triazine within 20 s of exposure to a silicon microcantilever with its gold surface modified with a self-assembled monolayer of 4-mercaptobenzoic acid. These measurements correspond to a limit of detection of a few fg.

  7. Novel Detection Method for Consecutive DC Commutation Failure Based on Daubechies Wavelet with 2nd-Order Vanishing Moments

    Directory of Open Access Journals (Sweden)

    Tao Lin

    2018-01-01

    Full Text Available Accurate detection and effective control strategy of commutation failure (CF of high voltage direct current (HVDC are of great significance for keeping the safe and stable operations of the hybrid power grid. At first, a novel detection method for consecutive CF is proposed. Concretely, the 2nd and higher orders’ derivative values of direct current are summarized as the core to judge CF by analyzing the physical characteristics of the direct current waveform of the converter station in CF. Then, the Daubechies wavelet coefficient that can represent the 2nd and higher order derivative values of direct current is derived. Once the wavelet coefficients of the sampling points are detected to exceed the threshold, the occurrence of CF is confirmed. Furthermore, by instantly increasing advanced firing angle β in the inverter side, an additional emergency control strategy to prevent subsequent CF is proposed. Eventually, with simulations of the benchmark model, the effectiveness and superiorities of the proposed detection method and additional control strategy in accuracy and rapidity are verified.

  8. Sulfur-adlayer-coated gold electrode for the in vitro electrochemical detection of uric acid in urine.

    Science.gov (United States)

    Miah, Md Rezwan; Alam, Muhammad Tanzirul; Ohsaka, Takeo

    2010-06-11

    The present article demonstrates the electrochemical oxidation of uric acid (UA) at sulfur-adlayer-coated gold (S-Au) electrode in alkaline media. At S-Au electrode, UA oxidized at a significantly lower overpotential with a higher current density as compared to the bare Au electrode. The oxidation of UA at the S-Au electrode is highly selective in the presence of the other commonly existing bio-molecules in urine. The proposed electrochemical sensor not only exhibited good reproducibility, but also showed a fast amperometric response to UA in the concentration range of 0.0025-5 mM with a low detection limit of 0.4 microM. Copyright 2010. Published by Elsevier B.V.

  9. Driver Vigilance in Automated Vehicles: Hazard Detection Failures Are a Matter of Time.

    Science.gov (United States)

    Greenlee, Eric T; DeLucia, Patricia R; Newton, David C

    2018-03-01

    The primary aim of the current study was to determine whether monitoring the roadway for hazards during automated driving results in a vigilance decrement. Although automated vehicles are relatively novel, the nature of human-automation interaction within them has the classic hallmarks of a vigilance task. Drivers must maintain attention for prolonged periods of time to detect and respond to rare and unpredictable events, for example, roadway hazards that automation may be ill equipped to detect. Given the similarity with traditional vigilance tasks, we predicted that drivers of a simulated automated vehicle would demonstrate a vigilance decrement in hazard detection performance. Participants "drove" a simulated automated vehicle for 40 minutes. During that time, their task was to monitor the roadway for roadway hazards. As predicted, hazard detection rate declined precipitously, and reaction times slowed as the drive progressed. Further, subjective ratings of workload and task-related stress indicated that sustained monitoring is demanding and distressing and it is a challenge to maintain task engagement. Monitoring the roadway for potential hazards during automated driving results in workload, stress, and performance decrements similar to those observed in traditional vigilance tasks. To the degree that vigilance is required of automated vehicle drivers, performance errors and associated safety risks are likely to occur as a function of time on task. Vigilance should be a focal safety concern in the development of vehicle automation.

  10. Detection of trace tetracycline in fish via synchronous fluorescence quenching with carbon quantum dots coated with molecularly imprinted silica

    Science.gov (United States)

    Yang, Ji; Lin, Zheng-Zhong; Nur, A.-Zha; Lu, Yan; Wu, Ming-Hui; Zeng, Jun; Chen, Xiao-Mei; Huang, Zhi-Yong

    2018-02-01

    A novel fluorescence-based sensor combining synchronous fluorescence spectroscopy (SFS) with molecularly imprinted polymers (MIPs) was fabricated with reverse microemulsion method. Tetracycline (TC), (3-aminopropyl) triethoxysilane (APTES), tetraethyl orthosilicate (TEOS) and carbon quantum dots (CDs) were used as template, functional monomer, cross-linker and signal sources respectively in the probe preparation. A synchronous fluorescence emission (λem) at 355 nm was observed for the prepared MIP-coated CDs (MIP@CDs) particles when the wavelength interval (Δλ) was set as 70 nm, and the synchronous fluorescence intensity could be rapidly and efficiently quenched by TC based on inner filter effect (IFE). The quenching efficiencies of synchronous fluorescence intensity was linearly fitted with tetracycline (TC) concentrations ranging from 0.1 to 50 μmol L- 1 with a detection limit (DL) of 9 nmol L- 1 (3σ, n = 9). The MIP@CDs was used as a probe to detect TC in fish samples with the recoveries ranging from 98.4% to 103.1% and the relative standard deviation less than 6.0%. The results illustrated that the as-prepared MIP@CDs could be applied to the detection of trace TC in fish samples with rapidity, high sensitivity and accuracy.

  11. The Performance of Short-Term Heart Rate Variability in the Detection of Congestive Heart Failure

    Directory of Open Access Journals (Sweden)

    Fausto Lucena

    2016-01-01

    Full Text Available Congestive heart failure (CHF is a cardiac disease associated with the decreasing capacity of the cardiac output. It has been shown that the CHF is the main cause of the cardiac death around the world. Some works proposed to discriminate CHF subjects from healthy subjects using either electrocardiogram (ECG or heart rate variability (HRV from long-term recordings. In this work, we propose an alternative framework to discriminate CHF from healthy subjects by using HRV short-term intervals based on 256 RR continuous samples. Our framework uses a matching pursuit algorithm based on Gabor functions. From the selected Gabor functions, we derived a set of features that are inputted into a hybrid framework which uses a genetic algorithm and k-nearest neighbour classifier to select a subset of features that has the best classification performance. The performance of the framework is analyzed using both Fantasia and CHF database from Physionet archives which are, respectively, composed of 40 healthy volunteers and 29 subjects. From a set of nonstandard 16 features, the proposed framework reaches an overall accuracy of 100% with five features. Our results suggest that the application of hybrid frameworks whose classifier algorithms are based on genetic algorithms has outperformed well-known classifier methods.

  12. Mining User-Generated Contents to Detect Service Failures with Topic Model

    OpenAIRE

    Kyung Bae Park; Sung Ho Ha

    2016-01-01

    Online user-generated contents (UGC) significantly change the way customers behave (e.g., shop, travel), and a pressing need to handle the overwhelmingly plethora amount of various UGC is one of the paramount issues for management. However, a current approach (e.g., sentiment analysis) is often ineffective for leveraging textual information to detect the problems or issues that a certain management suffers from. In this paper, we employ text mining of Latent Dirichlet Allocation (LDA) on a po...

  13. Iterative User Interface Design for Automated Sequential Organ Failure Assessment Score Calculator in Sepsis Detection.

    Science.gov (United States)

    Aakre, Christopher Ansel; Kitson, Jaben E; Li, Man; Herasevich, Vitaly

    2017-05-18

    The new sepsis definition has increased the need for frequent sequential organ failure assessment (SOFA) score recalculation and the clerical burden of information retrieval makes this score ideal for automated calculation. The aim of this study was to (1) estimate the clerical workload of manual SOFA score calculation through a time-motion analysis and (2) describe a user-centered design process for an electronic medical record (EMR) integrated, automated SOFA score calculator with subsequent usability evaluation study. First, we performed a time-motion analysis by recording time-to-task-completion for the manual calculation of 35 baseline and 35 current SOFA scores by 14 internal medicine residents over a 2-month period. Next, we used an agile development process to create a user interface for a previously developed automated SOFA score calculator. The final user interface usability was evaluated by clinician end users with the Computer Systems Usability Questionnaire. The overall mean (standard deviation, SD) time-to-complete manual SOFA score calculation time was 61.6 s (33). Among the 24% (12/50) usability survey respondents, our user-centered user interface design process resulted in >75% favorability of survey items in the domains of system usability, information quality, and interface quality. Early stakeholder engagement in our agile design process resulted in a user interface for an automated SOFA score calculator that reduced clinician workload and met clinicians' needs at the point of care. Emerging interoperable platforms may facilitate dissemination of similarly useful clinical score calculators and decision support algorithms as "apps." A user-centered design process and usability evaluation should be considered during creation of these tools. ©Christopher Ansel Aakre, Jaben E Kitson, Man Li, Vitaly Herasevich. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 18.05.2017.

  14. Investigation of Effectiveness of Some Vibration-Based Techniques in Early Detection of Real-Time Fatigue Failure in Gears

    Directory of Open Access Journals (Sweden)

    Hasan Ozturk

    2010-01-01

    Full Text Available Bending fatigue crack is a dangerous and insidious mode of failure in gears. As it produces no debris in its early stages, it gives little warning during its progression, and usually results in either immediate loss of serviceability or greatly reduced power transmitting capacity. This paper presents the applications of vibration-based techniques (i.e. conventional time and frequency domain analysis, cepstrum, and continuous wavelet transform to real gear vibrations in the early detection, diagnosis and advancement monitoring of a real tooth fatigue crack and compares their detection and diagnostic capabilities on the basis of experimental results. Gear fatigue damage is achieved under heavy-loading conditions and the gearbox is allowed to run until the gears suffer badly from complete tooth breakage. It has been found that the initiation and progression of fatigue crack cannot be easily detected by conventional time and frequency domain approaches until the fault is significantly developed. On the contrary, the wavelet transform is quite sensitive to any change in gear vibration and reveals fault features earlier than other methods considered.

  15. Influence of bone density and surgical treatment choice on failure of femoral neck fracture

    DEFF Research Database (Denmark)

    Viberg, Bjarke

    (bipolar vs. unipolar), cement, coating, and stem design In the literature there seems to be no difference in risk of failure when comparing unipolar HA with bipolar HA, the surgical approach, or the surgeons experience. However, there is an increased risk of failure associated with lower patient age, male...... gender, and with some uncemented stem designs. One of the papers in thesis finds a higher failure rate for older uncemented HA compared to cemented HA, especially after 5-10 years. The uncemented HA do not seem to benefit from hydroxy-apatite coating when failure rates for the uncemented HA were compared...... to those of the cemented HA. Generally, in studies assessing failure, the sample sizes are too small to detect small risk of increased failure, since the increased mortality in femoral neck fracture patients are not taken into account....

  16. Description of the global fuel element failure detection for SNR 300

    International Nuclear Information System (INIS)

    Dauk, J.

    1985-07-01

    For the detection of fission products in the cover gas of SNR 300 a high-resolution gamma-spectrometer with connected mini-computer is applied. The mechanical structure of the two Ge-detectors, which are positioned at two redundant gas lines, the analogous electronic and the structure of the computer with its periphery are described in this report. The concept of the software is presented, which had been developed especially for SNR 300. The start-up of the system and the calibration of the auxiliary measuring points and of the Ge-detectors are described [de

  17. Case Study: IBM Watson Analytics Cloud Platform as Analytics-as-a-Service System for Heart Failure Early Detection

    Directory of Open Access Journals (Sweden)

    Gabriele Guidi

    2016-07-01

    Full Text Available In the recent years the progress in technology and the increasing availability of fast connections have produced a migration of functionalities in Information Technologies services, from static servers to distributed technologies. This article describes the main tools available on the market to perform Analytics as a Service (AaaS using a cloud platform. It is also described a use case of IBM Watson Analytics, a cloud system for data analytics, applied to the following research scope: detecting the presence or absence of Heart Failure disease using nothing more than the electrocardiographic signal, in particular through the analysis of Heart Rate Variability. The obtained results are comparable with those coming from the literature, in terms of accuracy and predictive power. Advantages and drawbacks of cloud versus static approaches are discussed in the last sections.

  18. A versatile SERS-based immunoassay for immunoglobulin detection using antigen-coated gold nanoparticles and malachite green-conjugated protein A/G

    Science.gov (United States)

    A surface enhanced Raman scattering (SERS) immunoassay for antibody detection in serum is described in the present work. The developed assay is conducted in solution and utilizes Au nanoparticles coated with the envelope (E) protein of West Nile Virus (WNV) as the SERS-active substrate and malachite...

  19. Study for prevention of sucker rods failures though NiCr coating; Estudo para prevencao de falhas de hastes de bombeio de petroleo atraves de aplicacao de revestimento NiCr

    Energy Technology Data Exchange (ETDEWEB)

    Bezerra, Brunno S.L. [PETROBRAS, Rio de Janeiro, RJ (Brazil); Araujo, Paulo M.M. [Universidade Federal de Sergipe (UFS), Aracaju, SE (Brazil); Figueiredo, Renan T.; Cavalcanti, Eliane B. [Universidade Tiradentes, Aracaju, SE (Brazil)

    2008-07-01

    The use of common materials, as carbon steel, in sucker rods motivated by its low cost, in mature oil wells located on Sergipe, Alagoas, Bahia and Rio Grande do Norte states, which are subjected to tractive-compressive-abrasive like combined loads, added to aggressive environment (oil production in the presence of water, carbon dioxide, hydrogen sulfide, salinity, etc..), leads to the materials drastic degeneration and even its rupture. The substitution of common materials by those which have better resistance o failure is, therefore, limited by high cost. A much cheaper alternative is to modify the surface of common materials used in the subsurface equipment, by applying a protective coating in order to assure the system's performance, durability or better economic viability. In the present work it was studied the use of thermal sprayed NiCr coating in sucker rods. It was studied three thermal spray processes: flame spray, arc spray and HVOF (high velocity oxy fuel). (author)

  20. Anticorrosive coatings: a review

    DEFF Research Database (Denmark)

    Sørensen, Per Aggerholm; Kiil, Søren; Dam-Johansen, Kim

    2009-01-01

    of volatile organic compounds (VOCs) have caused significant changes in the anticorrosive coating industry. The requirement for new VOC-compliant coating technologies means that coating manufacturers can no longer rely on the extensive track record of their time-served products to convince consumers...... of their suitability for use. An important aspect in the development of new VOC-compliant, high-performance anticorrosive coating systems is a thorough knowledge of the components in anticorrosive coatings, their interactions, their advantages and limitations, as well as a detailed knowledge on the failure modes......, and inhibitive coatings are outlined. In the past decades, several alternatives to organic solvent-borne coatings have reached the commercial market. This review also presents some of these technologies and discusses some of their advantages and limitations. Finally, some of the mechanisms leading to degradation...

  1. Tungsten oxide coatings deposited by plasma spray using powder and solution precursor for detection of nitrogen dioxide gas

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chao, E-mail: zhangc@yzu.edu.cn [College of Mechanical Engineering, Yangzhou University, Yangzhou 225127 (China); Wang, Jie [College of Mechanical Engineering, Yangzhou University, Yangzhou 225127 (China); Geng, Xin [College of Mechanical Engineering, Yangzhou University, Yangzhou 225127 (China); College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002 (China)

    2016-05-25

    Increasing attention has been paid on preparation methods for resistive-type gas sensors based on semiconductor metal oxides. In this work, tungsten oxide (WO{sub 3}) coatings were prepared on alumina substrates and used as gas sensitive layers. The coatings were deposited by atmospheric plasma spray using powder, solution precursor, or a combination of both. Tungsten oxide powder through a powder port and ammonium tungstate aqueous solution through a liquid port were injected into plasma stream respectively or together to deposit WO{sub 3} coatings. Phase structures in the coatings were characterized by X-ray diffraction analyzer. The field-emission scanning electron microscopy images confirmed that the coatings were in microstructure, nanostructure or micro-nanostructure. The sensing properties of the sensors based on the coatings exposed to 1 ppm nitrogen dioxide gas were characterized in a home-made instrument. Sensing properties of the coatings were compared and discussed. The influences of gas humidity and working temperature on the sensor responses were further studied. - Highlights: • Porous gas sensitive coatings were deposited by plasma spray using powder and solution precursor. • Crystallized WO{sub 3} were obtained through hybrid plasma spray plus a pre-conditioned step. • Plasma power had an important influence on coating microstructure. • The particle size of atmospheric plasma-sprayed microstructured coating was stable. • Solution precursor plasma-sprayed WO{sub 3} coatings had nanostructure and showed good responses to 1 ppm NO{sub 2}.

  2. Implementing wavelet packet transform for valve failure detection using vibration and acoustic emission signals

    International Nuclear Information System (INIS)

    Sim, H Y; Ramli, R; Abdullah, M A K

    2012-01-01

    The efficiency of reciprocating compressors relies heavily on the health condition of its moving components, most importantly its valves. Previous studies showed good correlation between the dynamic response and the physical condition of the valves. These can be achieved by employing vibration technique which is capable of monitoring the response of the valve, and acoustic emission technique which is capable of detecting the valves' material deformation. However, the relationship/comparison between the two techniques is rarely investigated. In this paper, the two techniques were examined using time-frequency analysis. Wavelet packet transform (WPT) was chosen as the multi-resolution analysis technique over continuous wavelet transform (CWT), and discrete wavelet transform (DWT). This is because WPT could overcome the high computational time and high redundancy problem in CWT and could provide detailed analysis of the high frequency components compared to DWT. The features of both signals can be extracted by evaluating the normalised WPT coefficients for different time window under different valve conditions. By comparing the normalised coefficients over a certain time frame and frequency range, the feature vectors revealing the condition of valves can be constructed. One way analysis of variance was employed on these feature vectors to test the significance of data under different valve conditions. It is believed that AE signals can give a better representation of the valve condition as it can detect both the fluid motion and material deformation of valves as compared to the vibration signals.

  3. Failure Detection of Composites with Control System Corrective Response in Drone System Applications

    Directory of Open Access Journals (Sweden)

    Mark Bowkett

    2018-04-01

    Full Text Available The paper describes a novel method for the detection of damage in carbon composites as used in drone frames. When damage is detected a further novel corrective response is initiated in the quadcopter flight controller to switch from a four-arm control system to a three-arm control system. This is made possible as a symmetrical frame is utilized, which allows for a balanced weight distribution between both the undamaged quadcopter and the fallback tri-copter layout. The resulting work allows for continued flight where this was not previously possible. Further developing work includes improved flight stability with the aid of an underslung load model. This is beneficial to the quadcopter as a damaged arm attached to the main body by the motor wires behaves as an underslung load. The underslung load works are also transferable in a dual master and slave drone system where the master drone transports a smaller slave drone by a tether, which acts as an underslung load.

  4. A generic method for real time detection of magnetic sensor failure on tokamaks

    International Nuclear Information System (INIS)

    Nouailletas, Rémy; Moreau, Philippe; Bremond, Sylvain

    2012-01-01

    Highlights: ► We propose a generic method to detect and correct in real time faults on magnetic sensor. ► This method is applied to Tore Supra and tested offline with real data. ► Then the method is modified to be applied to ITER ex-vessel sensor configuration. ► The method is tested on the ITER case with simulated data. - Abstract: In tokamaks, magnetic field probe sensors are used to measure the plasma position. If a sensor provides a wrong data, the error may propagate through the control loop and cause undesirable contact between the vessel wall and the plasma. In the case of a tokamak with water cooled walls, these types of event may be very serious. Despite of these unlikely faults, the potential damages call for a real time check of magnetic sensor data before using them for control. In this paper a simple and generic method based on the comparison of each sensor to a weighted sum of its neighbors is proposed. From the analysis of the residue (the result of the comparison), the fault can be detected and compensated. The method is tuned and tested against Tore Supra experimental data. Then, the method is adapted to ITER and assessed on a reference ITER scenario using simulated magnetic sensor data.

  5. Usefulness of multimodality imaging for detection of myocardial infarction in patients with advanced kidney failure: case report

    Energy Technology Data Exchange (ETDEWEB)

    Veras, Mariana Ferreira; Azevedo, Jader Cunha de; Gamarski, Moisés; Mesquita, Evandro Tinoco; Mesquita, Cláudio Tinoco, E-mail: fvmari@gmail.com [Hospital Procardíaco, Rio de Janeiro, RJ (Brazil); Alves, José Galvão [Centro Universitário de Volta Redonda, RJ (Brazil)

    2016-01-15

    The third universal definition of acute myocardial infarction (AMI) is based on the elevation of troponin in association with ischemic symptoms, electrocardiographic changes and imaging findings. In patients with chest pain, the diagnosis of AMI is performed by dosing serum markers of myocardial necrosis, particularly troponins, by means of changes in 12 - lead electrocardiogram (ECG) or by identifying changes in the contractile dynamics of the left ventricle to the transthoracic echocardiogram. In some cases, confounding factors may hamper the diagnosis, such as: (a) presence of previous changes in the baseline ECG, especially LBBB; (b) elevations of myocardial necrosis markers (MNM) resulting from situations other than AMI and; (c) old changes in contractility detected by transthoracic ECG. Serum cardiac troponin (Tn) is the most specific and most used MNM for the diagnosis of AMI. Nevertheless, in some situations troponin elevation may not be due to an AMI, as in cases of acute pulmonary embolism, acute pericarditis, severe heart failure, myocarditis, and sepsis and kidney failure. Patients with kidney failure have high probability of concurrent cardiovascular disease. Furthermore, the cross-reacting proteins interfering with skeletal muscle, analytical imprecision and interactions with the dialysis membrane may cause elevation of troponin in 7% to 17% of patients with kidney failure. When in doubt about diagnosis of AMI, {sup 99m}Technetium pyrophosphate myocardial scintigraphy ({sup 99m}Tc-PYP) stands out as a noninvasive method capable of identifying areas of myocardial necrosis, thus helping in the diagnosis of AMI. {sup 99m}Tc-labeled phosphonate agents undergo chemical absorption with calcium. A large influx of calcium occurs during the evolutionary process of AMI. The calcium flows into the intracellular space and myocardial concentration of {sup 99m}Tc-PYP follows such increase, with a maximum peak uptake about 48 to 72 hours after the acute event. The

  6. Micro-Electromechanical Acoustic Resonator Coated with Polyethyleneimine Nanofibers for the Detection of Formaldehyde Vapor

    Directory of Open Access Journals (Sweden)

    Da Chen

    2018-02-01

    Full Text Available We demonstrate a promising strategy to combine the micro-electromechanical film bulk acoustic resonator and the nanostructured sensitive fibers for the detection of low-concentration formaldehyde vapor. The polyethyleneimine nanofibers were directly deposited on the resonator surface by a simple electrospinning method. The film bulk acoustic resonator working at 4.4 GHz acted as a sensitive mass loading platform and the three-dimensional structure of nanofibers provided a large specific surface area for vapor adsorption and diffusion. The ultra-small mass change induced by the absorption of formaldehyde molecules onto the amine groups in polyethyleneimine was detected by measuring the frequency downshift of the film bulk acoustic resonator. The proposed sensor exhibits a fast, reversible and linear response towards formaldehyde vapor with an excellent selectivity. The gas sensitivity and the detection limit were 1.216 kHz/ppb and 37 ppb, respectively. The study offers a great potential for developing sensitive, fast-response and portable sensors for the detection of indoor air pollutions.

  7. High Hydrogen Content Graphene Hydride Compounds & High Cross-Section Cladding Coatings for Fast Neutron Detection

    International Nuclear Information System (INIS)

    Chandrashekhar, MVS

    2017-01-01

    The objective is to develop and implement a superior low-cost, large area (potentially >32in), easily deployable, close proximity, harsh environment innovative neutron sensor needed for next generation fuel cycle monitoring. We will exploit recent breakthroughs at the PI's lab on the electrochemistry of epitaxial graphene (EG) formed on commercial SiC wafers, a transformative nanomaterial system with superior radiation detection and durability properties to develop a new paradigm in detection for fast neutrons, a by-product of fission reactors. There are currently few effective detection/monitoring schemes, especially solid-state ones at present. This is essential for monitoring and control of future fuel cycles to make them more efficient and reliable. By exploiting these novel materials, as well as innovative hybrid SiC/EG/Cladding device architectures conceived by the team, will develop low-cost, high performance solutions to fast-neutron detection. Finally, we will also explore 3-terminal device implementations for neutron detectors with built-in electronic gain to further shrink these devices and improve their sensitivity.

  8. Aptamer-Based electrochemiluminescent detection of MCF-7 cancer cells based on carbon quantum dots coated mesoporous silica nanoparticles

    International Nuclear Information System (INIS)

    Su, Min; Liu, Heng; Ge, Lei; Wang, Yanhu; Ge, Shenguang; Yu, Jinghua; Yan, Mei

    2014-01-01

    Graphical abstract: - Highlights: • Aptamers have many advantages over antibodies, such as low molecular weight, easy but reproducible production and low cost. • Mesoporous silica nanoparticles (MSNs) were prepared to load more CQDs for signal amplification which has a large surface area and high pore volume, ordered porous channels, a uniform and tunable pore structure, and a great diversity in surface functionalization • 3D-GR@AuNPs was prepared as biointerface for the immobilization of cancer cells due to their good biological compatibility, excellent conductivity and large surface area. • This new aptasensor may be quite promising, with potential broad applications in cancer early diagnosis due to the excellent analytical performance. - Abstract: In this work, we developed a novel electrochemiluminescence (ECL) platform for ultrasensitive and selective detection of MCF-7 cancer cells. To construct the platform, three-dimensional macroporous AuNPs@graphene complex was prepared through freeze drying process to modify glassy carbon electrode, which provided an effective matrix for concanavalin A to capture cancer cells due to its high surface area-to-weight ratio and excellent mechanical properties. The carbon quantum dots (CQDs) coated mesoporous silica nanoparticles were used as excellent ECL tracers due to their low cytotoxicity and good biocompatibility. Then, the prepared tracers were conjugated with mucin1 aptamer to specifically bind mucin1 on cancer cells with high stability and bioactivity. Structure characterization was obtained by means of transmission electron microscopy and scanning electron microscopy images. The proposed method showed a good analytical performance for the detection of MCF-7 cancer cells ranging from 500 to 2 × 10 7 cells·mL −1 with a detection limit of 230 cells mL −1 . The as-proposed device has the advantages of high sensitivity, nice specificity, and good stability and could offer great promise for sensitive

  9. Failure analysis of thermally cycled columnar thermal barrier coatings produced by high-velocity-air fuel and axial-suspension-plasma spraying: A design perspective

    Czech Academy of Sciences Publication Activity Database

    Ganvir, A.; Vaidhyanathan, V.; Markocsan, N.; Gupta, M.; Pala, Zdeněk; Lukáč, František

    2018-01-01

    Roč. 44, č. 3 (2018), s. 3161-3172 ISSN 0272-8842 Institutional support: RVO:61389021 Keywords : Columnar Thermal Barrier Coatings * Axial Suspension Plasma spraying * Thermal Cyclic Fatigue * High Velocity Air Fuel Spraying Subject RIV: JK - Corrosion ; Surface Treatment of Materials OBOR OECD: Coating and films Impact factor: 2.986, year: 2016 https://www.sciencedirect.com/science/article/pii/S0272884217325403

  10. Biocompatible Water Soluble Polyacrylic Acid Coated CdSe/Cu Quantum Dot Conjugates for Biomolecule Detection.

    Science.gov (United States)

    Gomaa, Ola M; Okasha, Aly; Hosni, Hany M; El-Hag Ali, Amr

    2018-01-01

    Biocompatible polyacrylic acid functionalized CdSe/Cu quantum dot conjugates were synthesized to be used for biomolecules detection. The study results demonstrate the conjugation of the 2.5-3 nm QD with gram negative bacteria with a low detection limit of 28 cfu/ml. The photoluminescence (PL) intensity was correlated to bacterial count, cellular proteins and exopolysaccharides in the tested samples. Confocal Scanning Laser Microscopy (CSLM) images showed significant QD uptake within the cells, both cytoplasm and DNA were the predominant targeted biomolecules, higher fluorescent uptake was shown in gram negative bacteria than that observed for gram positive bacteria. Moreover, PL showed that there was a distinction between live and dead cells as well as gram negative and gram positive cells. Cell viability was not affected even after 6 days (100% viability) rendering it a non-toxic QD. The method is simple and is performed in a single step within approximately 10 min as compared to multi-step protocols for classical microbial count or fluorescent dye staining. All the above results indicate that the CdSe/Cu-PAA QDs are suitable for biomolecule detection, bio-labeling and bioimaging applications.

  11. Multifunctional devices based on SnO2@rGO-coated fibers for human motion monitoring, ethanol detection, and photo response

    Science.gov (United States)

    Mi, Qing; Wang, Qi; Zang, Siyao; Chai, Zhaoer; Zhang, Jinnan; Ren, Xiaomin

    2018-05-01

    In this study, we developed a multifunctional device based on SnO2@rGO-coated fibers utilizing plasma treatment, dip coating, and microwave irradiation in sequence, and finally realized highly sensitive human motion monitoring, relatively good ethanol detection, and an obvious photo response. Moreover, the high level of comfort and compactness derived from highly elastic and comfortable fabrics contributes to the long-term availability and test accuracy. As an attempt at multifunctional integration of smart clothing, this work provides an attractive and relatively practical research direction.

  12. [Modal failure analysis and effects in the detection of errors in the transport of samples to the clinical laboratory].

    Science.gov (United States)

    Parés-Pollán, L; Gonzalez-Quintana, A; Docampo-Cordeiro, J; Vargas-Gallego, C; García-Álvarez, G; Ramos-Rodríguez, V; Diaz Rubio-García, M P

    2014-01-01

    Owing to the decrease in values of biochemical glucose parameter in some samples from external extraction centres, and the risk this implies to patient safety; it was decided to apply an adaptation of the «Health Services Failure Mode and Effects Analysis» (HFMEA) to manage risk during the pre-analytical phase of sample transportation from external centres to clinical laboratories. A retrospective study of glucose parameter was conducted during two consecutive months. The analysis was performed in its different phases: to define the HFMEA topic, assemble the team, graphically describe the process, conduct a hazard analysis, design the intervention and indicators, and identify a person to be responsible for ensuring completion of each action. The results of glucose parameter in one of the transport routes, were significantly lower (P=.006). The errors and potential causes of this problem were analysed, and criteria of criticality and detectability were applied (score≥8) in the decision tree. It was decided to: develop a document management system; reorganise extractions and transport routes in some centres; quality control of the sample container ice-packs, and the time and temperature during transportation. This work proposes quality indicators for controlling time and temperature of transported samples in the pre-analytical phase. Periodic review of certain laboratory parameters can help to detect problems in transporting samples. The HFMEA technique is useful for the clinical laboratory. Copyright © 2013 SECA. Published by Elsevier Espana. All rights reserved.

  13. Synthesis of cysteamine-coated CdTe quantum dots and its application in mercury (II) detection

    Energy Technology Data Exchange (ETDEWEB)

    Pei Jiying [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Department of Chemistry, University of Science and Technology of China (USTC), Hefei 230026 (China); Zhu Hui; Wang Xiaolei [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Zhang Hanchang [Department of Chemistry, University of Science and Technology of China (USTC), Hefei 230026 (China); Yang Xiurong, E-mail: xryang@ciac.jl.cn [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China)

    2012-12-13

    Highlights: Black-Right-Pointing-Pointer High-quality CA-CdTe QDs were synthesized with a kinetic-growth strategy. Black-Right-Pointing-Pointer The synthesis procedures were very simple. Black-Right-Pointing-Pointer The obtained QDs were used to detect Hg{sup 2+} without the interference of Cu{sup 2+}. - Abstract: High-quality cysteamine-coated CdTe quantum dots (CA-CdTe QDs) were successfully synthesized in aqueous phase by a facile one-pot method. Through hydroxylamine hydrochloride-promoted kinetic growth strategy, water-soluble CA-CdTe QDs could be obtained conveniently in a conical flask by a stepwise addition of raw materials. The photoluminescence quantum yield (PL QY) of the obtained QDs reached 9.2% at the emission peak of 520 nm. The optical property and the morphology of the QDs were characterized by UV-vis absorption spectra, photoluminescence spectra (PL) and transmission electron microscopy (TEM) respectively. Furthermore, the fluorescence of the resultant QDs was quenched by copper (II) (Cu{sup 2+}) and mercury (II) (Hg{sup 2+}) meanwhile. It is worthy of note that to separately detect Hg{sup 2+}, cyanide ion could be used to eliminate the interference of Cu{sup 2+}. Under the optimal conditions, the response was linearly proportional to the logarithm of Hg{sup 2+} concentration over the range of 0.08-3.33 {mu}M with a limit of detection (LOD) of 0.07 {mu}M.

  14. Label-free SERS detection of relevant bioanalytes on silver-coated carbon nanotubes: The case of cocaine

    Science.gov (United States)

    Sanles-Sobrido, Marcos; Rodríguez-Lorenzo, Laura; Lorenzo-Abalde, Silvia; González-Fernández, África; Correa-Duarte, Miguel A.; Alvarez-Puebla, Ramón A.; Liz-Marzán, Luis M.

    2009-09-01

    Surface-enhanced Raman scattering (SERS) spectroscopy can be used for the label-free determination and quantification of relevant small biometabolites that are hard to identify by conventional immunological methods, in the absence of labelling. In this work, detection is based on monitoring the vibrational changes occurring at a specific biointerface (a monoclonal antibody, mAb) supported on silver-coated carbon nanotubes (CNT@Ag). Engineered CNT@Ag play a key role, as they offer a stable substrate to support the biointerface, with a high density of hot spots. Proof of concept is demonstrated through the analysis and quantification of the main cocaine metabolite benzoylecgonine. These results open a new avenue toward the generation of portable sensors for fast ultradetection and quantification of relevant metabolites. The use of discrete particles (CNT@Ag@mAb) rather than rough films, or other conventional SERS supports, will also enable a safe remote interrogation of highly toxic sources in environmental problems or in biological fluids.Surface-enhanced Raman scattering (SERS) spectroscopy can be used for the label-free determination and quantification of relevant small biometabolites that are hard to identify by conventional immunological methods, in the absence of labelling. In this work, detection is based on monitoring the vibrational changes occurring at a specific biointerface (a monoclonal antibody, mAb) supported on silver-coated carbon nanotubes (CNT@Ag). Engineered CNT@Ag play a key role, as they offer a stable substrate to support the biointerface, with a high density of hot spots. Proof of concept is demonstrated through the analysis and quantification of the main cocaine metabolite benzoylecgonine. These results open a new avenue toward the generation of portable sensors for fast ultradetection and quantification of relevant metabolites. The use of discrete particles (CNT@Ag@mAb) rather than rough films, or other conventional SERS supports, will also

  15. Multiwalled carbon nanotubes coated fibers for solid-phase microextraction of polybrominated diphenyl ethers in water and milk samples before gas chromatography with electron-capture detection.

    Science.gov (United States)

    Wang, Jun-Xia; Jiang, Dong-Qing; Gu, Zhi-Yuan; Yan, Xiu-Ping

    2006-12-22

    Determination of polybrominated diphenyl ethers (PBDEs) in environmental samples has raised great concerns due to the widespread use of PBDEs and their potential risk to humans. Solid-phase microextraction (SPME) is a fast, simple, cost-effective, and green sample preparation technique and is widely used for environmental analysis, but reports on the application of SPME for determination of PBDEs are very limited, and only a few publications dealing with commercial SPME fibers are available for extraction of PBDEs. Herein, we report a novel SPME method using multiwalled carbon nanotubes (MWCNTs) as the SPME fiber coating for gas chromatography with electron-capture detection (GC-ECD) of PBDEs in environmental samples. The MWCNTs coating gave much higher enhancement factors (616-1756) than poly (5% dibenzene-95% dimethylsiloxane) coating (139-384) and activated carbon coating (193-423). Thirty-minute extraction of 10 mL of sample solution using the MWCNTs coated fiber for GC-ECD determination yielded the limits of detection of 3.6-8.6 ng L(-1) and exhibited good linearity of the calibration functions (r(2)>0.995). The precision (RSD%, n=4) for peak area and retention time at the 500 ng L(-1) level was 6.9-8.8% and 0.6-0.9%, respectively. The developed method was successfully applied for the analysis of real samples including local river water, wastewater, and milk samples. The recovery of the PBDEs at 500 ng L(-1) spiked in these samples ranged from 90 to 119%. No PBDEs were detected in the river water and skimmed milk samples, whereas in the wastewater sample, 134-215 ng L(-1) of PBDEs were found. The PBDEs were detected in all whole fat milk samples, ranging from 13 to 484 ng L(-1). In a semiskimmed milk sample, only BDE-47 was found at 21 ng L(-1).

  16. Cadmium (II) imprinted 3-mercaptopropyltrimethoxysilane coated stir bar for selective extraction of trace cadmium from environmental water samples followed by inductively coupled plasma mass spectrometry detection

    International Nuclear Information System (INIS)

    Zhang Nan; Hu Bin

    2012-01-01

    Graphical abstract: Ion imprinted 3-mercaptopropyltrimethoxysilane (MPTS) coated stir bar for selective extraction of trace Cd(II). Highlights: ► Ion imprinted polymers were proposed as the coating for SBSE for the first time. ► Cd(II) imprinted MPTS-silica coating was prepared by a double-imprinting concept. ► A novel method of SBSE–ICP-MS was developed for the determination of Cd in waters. ► This method is rapid, selective, sensitive and applicable for determining trace Cd(II) in waters. - Abstract: Cd(II) imprinted 3-mercaptopropyltrimethoxysilane (MPTS)-silica coated stir bar was prepared by sol–gel technique combining with a double-imprinting concept for the first time and was employed for stir bar sorptive extraction (SBSE) of trace Cd(II) from water samples followed by inductively coupled plasma mass spectrometry (ICP-MS) detection. A tetramethoxysilane (TMOS) coating was first in situ created on the glass bar surface. Afterward, a sol solution containing MPTS as the functional precursor, ethanol as the solvent and both Cd(II) and surfactant micelles (cetyltrimethylammonium bromide, CTAB) as the template was again coated on the TMOS bar. The structures of the stir bar coating were characterized by FT-IR spectroscopy. Round-bottom vial was used for the extraction of Cd(II) by SBSE to avoid abrasion of stir bar coatings. The factors affecting the extraction of Cd(II) by SBSE such as pH, stirring rate and time, sample/elution volume and interfering ions have been investigated in detail, and the optimized experimental parameters were obtained. Under the optimized conditions, the adsorption capacities of non-imprinted and imprinted coating stir bars were found to be 0.5 μg and 0.8 μg bar −1 . The detection limit (3σ) based on three times standard deviations of the method blanks by 7 replicates was 4.40 ng L −1 and the relative standard deviation (RSD) was 3.38% (c = 1 μg L −1 , n = 7). The proposed method was successfully applied for the

  17. Cadmium (II) imprinted 3-mercaptopropyltrimethoxysilane coated stir bar for selective extraction of trace cadmium from environmental water samples followed by inductively coupled plasma mass spectrometry detection

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Nan [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072 (China); Hu Bin, E-mail: binhu@whu.edu.cn [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072 (China)

    2012-04-20

    Graphical abstract: Ion imprinted 3-mercaptopropyltrimethoxysilane (MPTS) coated stir bar for selective extraction of trace Cd(II). Highlights: Black-Right-Pointing-Pointer Ion imprinted polymers were proposed as the coating for SBSE for the first time. Black-Right-Pointing-Pointer Cd(II) imprinted MPTS-silica coating was prepared by a double-imprinting concept. Black-Right-Pointing-Pointer A novel method of SBSE-ICP-MS was developed for the determination of Cd in waters. Black-Right-Pointing-Pointer This method is rapid, selective, sensitive and applicable for determining trace Cd(II) in waters. - Abstract: Cd(II) imprinted 3-mercaptopropyltrimethoxysilane (MPTS)-silica coated stir bar was prepared by sol-gel technique combining with a double-imprinting concept for the first time and was employed for stir bar sorptive extraction (SBSE) of trace Cd(II) from water samples followed by inductively coupled plasma mass spectrometry (ICP-MS) detection. A tetramethoxysilane (TMOS) coating was first in situ created on the glass bar surface. Afterward, a sol solution containing MPTS as the functional precursor, ethanol as the solvent and both Cd(II) and surfactant micelles (cetyltrimethylammonium bromide, CTAB) as the template was again coated on the TMOS bar. The structures of the stir bar coating were characterized by FT-IR spectroscopy. Round-bottom vial was used for the extraction of Cd(II) by SBSE to avoid abrasion of stir bar coatings. The factors affecting the extraction of Cd(II) by SBSE such as pH, stirring rate and time, sample/elution volume and interfering ions have been investigated in detail, and the optimized experimental parameters were obtained. Under the optimized conditions, the adsorption capacities of non-imprinted and imprinted coating stir bars were found to be 0.5 {mu}g and 0.8 {mu}g bar{sup -1}. The detection limit (3{sigma}) based on three times standard deviations of the method blanks by 7 replicates was 4.40 ng L{sup -1} and the relative standard

  18. Detection of polydimethylsiloxanes transferred from silicone-coated parchment paper to baked goods using direct analysis in real time mass spectrometry.

    Science.gov (United States)

    Jakob, Andreas; Crawford, Elizabeth A; Gross, Jürgen H

    2016-04-01

    The non-stick properties of parchment papers are achieved by polydimethylsiloxane (PDMS) coatings. During baking, PDMS can thus be extracted from the silicone-coated parchment into the baked goods. Positive-ion direct analysis in real time (DART) mass spectrometry (MS) is highly efficient for the analysis of PDMS. A DART-SVP source was coupled to a quadrupole-time-of-flight mass spectrometer to detect PDMS on the contact surface of baked goods after use of silicone-coated parchment papers. DART spectra from the bottom surface of baked cookies and pizzas exhibited signals because of PDMS ions of the general formula [(C2H6SiO)n  + NH4 ](+) in the m/z 800-1900 range. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Memory effect, resolution, and efficiency measurements of an Al{sub 2}O{sub 3} coated plastic scintillator used for radioxenon detection

    Energy Technology Data Exchange (ETDEWEB)

    Bläckberg, L., E-mail: lisa.blackberg@physics.uu.se [Department of Physics and Astronomy, Uppsala University, Box 516, SE-75120 Uppsala (Sweden); Fritioff, T.; Mårtensson, L.; Nielsen, F.; Ringbom, A. [Division of Defence and Security Systems, Swedish Defence Research Agency (FOI), SE-17290 Stockholm (Sweden); Sjöstrand, H.; Klintenberg, M. [Department of Physics and Astronomy, Uppsala University, Box 516, SE-75120 Uppsala (Sweden)

    2013-06-21

    A cylindrical plastic scintillator cell, used for radioxenon monitoring within the verification regime of the Comprehensive Nuclear-Test-Ban Treaty, has been coated with 425 nm Al{sub 2}O{sub 3} using low temperature Atomic Layer Deposition, and its performance has been evaluated. The motivation is to reduce the memory effect caused by radioxenon diffusing into the plastic scintillator material during measurements, resulting in an elevated detection limit. Measurements with the coated detector show both energy resolution and efficiency comparable to uncoated detectors, and a memory effect reduction of a factor of 1000. Provided that the quality of the detector is maintained for a longer period of time, Al{sub 2}O{sub 3} coatings are believed to be a viable solution to the memory effect problem in question.

  20. White-coat, masked and sustained hypertension detected by home blood pressure monitoring in adolescents: prevalence and associated factors.

    Science.gov (United States)

    Jardim, Thiago Veiga; Carneiro, Carolina de Souza; Morais, Polyana; Roriz, Vanessa; Mendonça, Karla Lorena; Nascente, Flávia Miquetichuc; Póvoa, Thaís Inácio Rolim; Barroso, Weimar Kunz Sebba; Sousa, Ana Luiza Lima; Jardim, Paulo César Veiga

    2018-06-01

    Population-based studies estimating prevalence's of white-coat, masked and sustained hypertension in non-European adolescents are needed, particularly in developing countries. Aiming to determine these estimates and, additionally identify factors associated to these conditions this study was conducted. Cross-sectional study with a representative sample of secondary school students from a Brazilian state capital. Office measurements were performed with validated semi-automatic devices. Home BP (blood pressure) monitoring protocol included two day-time and two evening-time measurements over 6 days. Adolescents' were classified as: normotensives (office and home BP coat hypertensives (office BP ≥95th percentile and home BP coat, masked and sustained hypertension. In a sample of 1024 adolescents, prevalence of white-coat, masked and sustained hypertension was 7.5%, 2.2% and 1.7%, respectively. Male sex was positively associated with white-coat hypertension (OR 2.68; 95%CI 1.58-4.54; p coat (OR 1.23; 95%CI 1.16-1.30; p coat hypertension, masked and sustained hypertension in a population of non-European adolescents assessed by home BP monitoring was 7.5%, 2.2% and 1.7% respectively. Male sex was positively associated with white-coat hypertension in these adolescents while BMI was positively associated with both white-coat and sustained hypertension.

  1. Detecting Slow Deformation Signals Preceding Dynamic Failure: A New Strategy For The Mitigation Of Natural Hazards (SAFER)

    Science.gov (United States)

    Vinciguerra, S.; Colombero, C.; Comina, C.; Umili, G.

    2015-12-01

    Rock slope monitoring is a major aim in territorial risk assessment and mitigation. The use of "site specific" microseismic monitoring systems can allow to detect pre-failure signals in unstable sectors within the rock mass and to predict the possible acceleration to the failure. To this aim multi-scale geophysical methods can provide a unique tool for an high-resolution imaging of the internal structure of the rock mass and constraints on the physical state of the medium. We present here a cross-hole seismic tomography survey coupled with laboratory ultrasonic velocity measurements and determination of physical properties on rock samples to characterize the damaged and potentially unstable granitic cliff of Madonna del Sasso (NW, Italy). Results allowed to achieve two main advances, in terms of obtaining: i) a lithological interpretation of the velocity field obtained at the site, ii) a systematic correlation of the measured velocities with physical properties (density and porosity) and macroscopic features of the granite (weathering and anisotropy) of the cliff. A microseismic monitoring system developed by the University of Turin/Compagnia San Paolo, consisting of a network of 4 triaxial geophones (4.5 Hz) connected to a 12-channel data logger, has been deployed on the unstable granitic cliff. More than 2000 events with different waveforms, duration and frequency content were recorded between November 2013 and July 2014. By inspecting the acquired events we identified the key parameters for a reliable distinction among the nature of each signal, i.e. the signal shape (in terms of amplitude, duration, kurtosis) and the frequency content (maximum frequency content and frequency distribution). Four main classes of recorded signals can be recognised: microseismic events, regional earthquakes, electrical noises and calibration signals, and unclassified events (probably grouping rockfalls, quarry blasts, other anthropic and natural sources of seismic noise).

  2. Echographic detectability of optoacoustic signals from low-concentration PEG-coated gold nanorods.

    Science.gov (United States)

    Conversano, Francesco; Soloperto, Giulia; Greco, Antonio; Ragusa, Andrea; Casciaro, Ernesto; Chiriacò, Fernanda; Demitri, Christian; Gigli, Giuseppe; Maffezzoli, Alfonso; Casciaro, Sergio

    2012-01-01

    To evaluate the diagnostic performance of gold nanorod (GNR)-enhanced optoacoustic imaging employing a conventional echographic device and to determine the most effective operative configuration in order to assure optoacoustic effectiveness, nanoparticle stability, and imaging procedure safety. The most suitable laser parameters were experimentally determined in order to assure nanoparticle stability during the optoacoustic imaging procedures. The selected configuration was then applied to a novel tissue-mimicking phantom, in which GNR solutions covering a wide range of low concentrations (25-200 pM) and different sample volumes (50-200 μL) were exposed to pulsed laser irradiation. GNR-emitted optoacoustic signals were acquired either by a couple of single-element ultrasound probes or by an echographic transducer. Off-line analysis included: (a) quantitative evaluation of the relationships between GNR concentration, sample volume, phantom geometry, and amplitude of optoacoustic signals propagating along different directions; (b) echographic detection of "optoacoustic spots," analyzing their intensity, spatial distribution, and clinical exploitability. MTT measurements performed on two different cell lines were also used to quantify biocompatibility of the synthesized GNRs in the adopted doses. Laser irradiation at 30 mJ/cm(2) for 20 seconds resulted in the best compromise among the requirements of effectiveness, safety, and nanoparticle stability. Amplitude of GNR-emitted optoacoustic pulses was proportional to both sample volume and concentration along each considered propagation direction for all the tested boundary conditions, providing an experimental confirmation of isotropic optoacoustic emission. Average intensity of echographically detected spots showed similar behavior, emphasizing the presence of an "ideal" GNR concentration (100 pM) that optimized optoacoustic effectiveness. The tested GNRs also exhibited high biocompatibility over the entire considered

  3. Is Thrombus With Subcutaneous Edema Detected by Ultrasonography Related to Short Peripheral Catheter Failure? A Prospective Observational Study.

    Science.gov (United States)

    Takahashi, Toshiaki; Murayama, Ryoko; Oe, Makoto; Nakagami, Gojiro; Tanabe, Hidenori; Yabunaka, Koichi; Arai, Rika; Komiyama, Chieko; Uchida, Miho; Sanada, Hiromi

    Short peripheral catheter (SPC) failure is an important clinical problem. The purpose of this study was to clarify the relationship between SPC failure and etiologies such as thrombus, subcutaneous edema, and catheter dislodgment using ultrasonography and to explore the risk factors associated with the etiologies. Two hundred catheters that were in use for infusion, excluding chemotherapy, were observed. Risk factors were examined by logistic regression analysis. Sixty catheters were removed as the result of SPC failure. Frequency of thrombus with subcutaneous edema in SPC failure cases was significantly greater than in those cases where therapy was completed without complications (P edema. Results suggest that subsurface skin assessment for catheterization could prevent SPC failure.

  4. Echographic detectability of optoacoustic signals from low-concentration PEG-coated gold nanorods

    Directory of Open Access Journals (Sweden)

    Conversano F

    2012-08-01

    Full Text Available Francesco Conversano,1 Giulia Soloperto,1 Antonio Greco,1 Andrea Ragusa,1,2 Ernesto Casciaro,1 Fernanda Chiriacò,1 Christian Demitri,3 Giuseppe Gigli,2–5 Alfonso Maffezzoli,3 Sergio Casciaro11National Research Council, Institute of Clinical Physiology, Lecce, Italy; 2National Nanotechnology Laboratory of CNR-NANO, Lecce, Italy; 3University of Salento, Department of Engineering for Innovation, Lecce, Italy; 4Italian Institute of Technology – Center for Biomolecular Nanotechnology (CBN-IIT, Arnesano, Italy; 5University of Salento, Department of Mathematics and Physics ‘Ennio De Giorgi’, Lecce, ItalyPurpose: To evaluate the diagnostic performance of gold nanorod (GNR-enhanced optoacoustic imaging employing a conventional echographic device and to determine the most effective operative configuration in order to assure optoacoustic effectiveness, nanoparticle stability, and imaging procedure safety.Methods: The most suitable laser parameters were experimentally determined in order to assure nanoparticle stability during the optoacoustic imaging procedures. The selected configuration was then applied to a novel tissue-mimicking phantom, in which GNR solutions covering a wide range of low concentrations (25–200 pM and different sample volumes (50–200 µL were exposed to pulsed laser irradiation. GNR-emitted optoacoustic signals were acquired either by a couple of single-element ultrasound probes or by an echographic transducer. Off-line analysis included: (a quantitative evaluation of the relationships between GNR concentration, sample volume, phantom geometry, and amplitude of optoacoustic signals propagating along different directions; (b echographic detection of “optoacoustic spots,” analyzing their intensity, spatial distribution, and clinical exploitability. MTT measurements performed on two different cell lines were also used to quantify biocompatibility of the synthesized GNRs in the adopted doses.Results: Laser irradiation at

  5. Silica Gel Coated Spherical Micro resonator for Ultra-High Sensitivity Detection of Ammonia Gas Concentration in Air.

    Science.gov (United States)

    Mallik, Arun Kumar; Farrell, Gerald; Liu, Dejun; Kavungal, Vishnu; Wu, Qiang; Semenova, Yuliya

    2018-01-26

    A silica gel coated microsphere resonator is proposed and experimentally demonstrated for measurements of ammonia (NH 3 ) concentration in air with ultra-high sensitivity. The optical properties of the porous silica gel layer change when it is exposed to low (parts per million (ppm)) and even ultra-low (parts per billion (ppb)) concentrations of ammonia vapor, leading to a spectral shift of the WGM resonances in the transmission spectrum of the fiber taper. The experimentally demonstrated sensitivity of the proposed sensor to ammonia is estimated as 34.46 pm/ppm in the low ammonia concentrations range from 4 ppm to 30 ppm using an optical spectrum analyser (OSA), and as 800 pm/ppm in the ultra-low range of ammonia concentrations from 2.5 ppb to 12 ppb using the frequency detuning method, resulting in the lowest detection limit (by two orders of magnitude) reported to date equal to 0.16 ppb of ammonia in air. In addition, the sensor exhibits excellent selectivity to ammonia and very fast response and recovery times measured at 1.5 and 3.6 seconds, respectively. Other attractive features of the proposed sensor are its compact nature, simplicity of fabrication.

  6. Immobilization of ruthenium phthalocyanine on silica-coated multi-wall partially oriented carbon nanotubes: Electrochemical detection of fenitrothion pesticide

    Energy Technology Data Exchange (ETDEWEB)

    Canevari, Thiago C., E-mail: tccanevari@gmail.com [Engineering School, Mackenzie Presbyterian University, 01302-907 São Paulo, SP (Brazil); Prado, Thiago M.; Cincotto, Fernando H.; Machado, Sergio A.S. [Institute of Chemistry, State University of São Paulo, P.O. Box 780, 13560-970 São Carlos, SP (Brazil)

    2016-04-15

    Highlights: • Hybrid material, SiO{sub 2}/MWCNTs containing ruthenium phthalocyanine (RuPc) synthesized in situ. • Silica containing multi-walled carbon nanotube partially oriented. • Determination of pesticide fenitrothion in orange juice. - Abstract: This paper reports on the determination of the pesticide fenitrothion using a glassy carbon electrode modified with silica-coated, multi-walled, partially oriented carbon nanotubes, SiO{sub 2}/MWCNTs, containing ruthenium phthalocyanine (RuPc) synthesized in situ. The hybrid SiO{sub 2}/MWCNTs/RuPc material was characterized by UV–vis absorption spectroscopy, X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), high-resolution transmission electron microscopy (HR-TEM) and differential pulse voltammetry. The modified electrode showed well-defined peaks in the presence of fenitrothion in acetate buffer, pH 4.5, with a sensitivity of 0.0822 μA μM{sup −1} mm{sup −2} and a detection limit of 0.45 ppm. Notably, the modified SiO{sub 2}/MWCNTs/RuPc electrodes with did not suffer from significant influences in the presence of other organophosphorus pesticides during the determination of the fenitrothion pesticide. Moreover, this modified electrode showed excellent performance in the determination of fenitrothion in orange juice.

  7. A novel EIS field effect structures coated with TESUD-PPy-PVC-dibromoaza[7]helicene matrix for potassium ions detection

    Energy Technology Data Exchange (ETDEWEB)

    Tounsi, Moncef, E-mail: tounsi1981@live.fr [Laboratoire des Interfaces et des Matériaux Avancés (LIMA), Faculté des Sciences de Monastir, Université de Monastir (Tunisia); Université de Lyon, Institut de Sciences Analytiques (ISA) – UMR 5280, 5 rue de la Doua, 69100 Villeurbanne (France); Ben Braiek, Mourad [Laboratoire de Synthèse Organique Asymétrique et Catalyse Homogène, Faculté des Sciences, Université de Monastir, Avenue de l' environnement, 5019, Monastir (Tunisia); Barhoumi, Houcine [Laboratoire des Interfaces et des Matériaux Avancés (LIMA), Faculté des Sciences de Monastir, Université de Monastir (Tunisia); Baraket, Abdoullatif; Lee, Michael; Zine, Nadia [Université de Lyon, Institut de Sciences Analytiques (ISA) – UMR 5280, 5 rue de la Doua, 69100 Villeurbanne (France); Maaref, Abderrazak [Laboratoire des Interfaces et des Matériaux Avancés (LIMA), Faculté des Sciences de Monastir, Université de Monastir (Tunisia); Errachid, Abdelhamid, E-mail: abdelhamid.errachid-el-salhi@univ-lyon1.fr [Université de Lyon, Institut de Sciences Analytiques (ISA) – UMR 5280, 5 rue de la Doua, 69100 Villeurbanne (France)

    2016-04-01

    In this work, we describe the development of new Aza[7]helicene-containing PVC-based membranes for the K{sup +} ions quantification. Here, silicon nitride-based structures (Si-p/SiO{sub 2}/Si{sub 3}N{sub 4}) were developed and the surface was activated, functionalized with an aldehyde–silane (11-(Triethoxysilyl)undecanal (TESUD)), functionalized with polypyrrole (PPy), and coated with the polyvinylchloride (PVC)-membrane containing the Aza[7]helicene as ionophore. All stages of functionalization process have been thoroughly studied by contact angle measurements (CAMs) and atomic force microscopy (AFM). The developed ion-selective electrode (ISE) was then applied using electrochemical impedance spectroscopy (EIS) for the detection of potassium ions. A linear range was observed between 1.0 × 10{sup −8} M to 1.0 × 10{sup −3} M and a detection limit of 1.0 × 10{sup −8} M was observed. The EIS results have showed a good sensitivity to potassium ion using this novel technique. The target helicene exhibited good solubility and excellent thermal stability with a high decomposition temperature (Td > 300 °C) and it indicates that helicene may be a promising material as ionophore for ion-selective electrodes (ISEs) elaboration. - Highlights: • Synthesis and characterization of a new derivatives of Aza[7]helicenes • Manufacture of PPy structures on the SiO{sub 2}/Si{sub 3}N{sub 4} surface using the TESUD as cross linking agent. • The PPy fabricated microstructures can be used as support matrix in biosensing. • Impedimetric K{sup +}-ISEs was developed by using dibromoaza[7]helicene as ionophore for K{sup +} ions determination.

  8. Sensitive and Specific Biomimetic Lipid Coated Microfluidics to Isolate Viable Circulating Tumor Cells and Microemboli for Cancer Detection.

    Directory of Open Access Journals (Sweden)

    Jia-Yang Chen

    Full Text Available Here we presented a simple and effective membrane mimetic microfluidic device with antibody conjugated supported lipid bilayer (SLB "smart coating" to capture viable circulating tumor cells (CTCs and circulating tumor microemboli (CTM directly from whole blood of all stage clinical cancer patients. The non-covalently bound SLB was able to promote dynamic clustering of lipid-tethered antibodies to CTC antigens and minimized non-specific blood cells retention through its non-fouling nature. A gentle flow further flushed away loosely-bound blood cells to achieve high purity of CTCs, and a stream of air foam injected disintegrate the SLB assemblies to release intact and viable CTCs from the chip. Human blood spiked cancer cell line test showed the ~95% overall efficiency to recover both CTCs and CTMs. Live/dead assay showed that at least 86% of recovered cells maintain viability. By using 2 mL of peripheral blood, the CTCs and CTMs counts of 63 healthy and colorectal cancer donors were positively correlated with the cancer progression. In summary, a simple and effective strategy utilizing biomimetic principle was developed to retrieve viable CTCs for enumeration, molecular analysis, as well as ex vivo culture over weeks. Due to the high sensitivity and specificity, it is the first time to show the high detection rates and quantity of CTCs in non-metastatic cancer patients. This work offers the values in both early cancer detection and prognosis of CTC and provides an accurate non-invasive strategy for routine clinical investigation on CTCs.

  9. Detecting Slow Deformation Signals Preceding Dynamic Failure: A New Strategy For The Mitigation Of Natural Hazards (SAFER)

    Science.gov (United States)

    Vinciguerra, Sergio; Colombero, Chiara; Comina, Cesare; Ferrero, Anna Maria; Mandrone, Giuseppe; Umili, Gessica; Fiaschi, Andrea; Saccorotti, Gilberto

    2015-04-01

    Rock slope monitoring is a major aim in territorial risk assessment and mitigation. The high velocity that usually characterizes the failure phase of rock instabilities makes the traditional instruments based on slope deformation measurements not applicable for early warning systems. The use of "site specific" microseismic monitoring systems, with particular reference to potential destabilizing factors, such as rainfalls and temperature changes, can allow to detect pre-failure signals in unstable sectors within the rock mass and to predict the possible acceleration to the failure. We deployed a microseismic monitoring system in October 2013 developed by the University of Turin/Compagnia San Paolo and consisting of a network of 4 triaxial 4.5 Hz seismometers connected to a 12 channel data logger on an unstable patch of the Madonna del Sasso, Italian Western Alps. The initial characterization based on geomechanical and geophysical tests allowed to understand the instability mechanism and to design a 'large aperture' configuration which encompasses the entire unstable rock and can monitor subtle changes of the mechanical properties of the medium. Stability analysis showed that the stability of the slope is due to rock bridges. A continuous recording at 250 Hz sampling frequency (switched in March 2014 to 1 kHz for improving the first arrival time picking and obtain wider frequency content information) and a trigger recording based on a STA/LTA (Short Time Average over Long Time Average) detection algorithm have been used. More than 2000 events with different waveforms, duration and frequency content have been recorded between November 2013 and March 2014. By inspecting the acquired events we identified the key parameters for a reliable distinction among the nature of each signal, i.e. the signal shape in terms of amplitude, duration, kurtosis and the frequency content in terms of range of maximum frequency content, frequency distribution in spectrograms. Four main

  10. A Failure Detection Strategy for Intrafraction Prostate Motion Monitoring With On-Board Imagers for Fixed-Gantry IMRT

    International Nuclear Information System (INIS)

    Liu Wu; Luxton, Gary; Xing Lei

    2010-01-01

    Purpose: To develop methods to monitor prostate intrafraction motion during fixed-gantry intensity-modulated radiotherapy using MV treatment beam imaging together with minimal kV imaging for a failure detection strategy that ensures prompt detection when target displacement exceeds a preset threshold. Methods and Materials: Real-time two-dimensional (2D) marker position in the MV image plane was obtained by analyzing cine-MV images. The marker's in-line movement, and thus its time-varying three-dimensional (3D) position, was estimated by combining the 2D projection data with a previously established correlative relationship between the directional components of prostate motion. A confirmation request for more accurate localization using MV-kV triangulation was triggered when the estimated prostate displacement based on the cine-MV data was greater than 3 mm. An interventional action alert followed on positive MV-kV confirmation. To demonstrate the feasibility and accuracy of the proposed method, simulation studies of conventional-fraction intensity-modulated radiotherapy sessions were done using 536 Calypso-measured prostate trajectories from 17 radiotherapy patients. Results: A technique for intrafraction prostate motion management has been developed. The technique, using 'freely available' cine-MV images and minimum on-board kV imaging (on average 2.5 images/fraction), successfully limited 3D prostate movement to within a range of 3 mm relative to the MV beam for 99.4% of the total treatment time. On average, only approximately one intervention/fraction was needed to achieve this level of accuracy. Conclusion: Instead of seeking to accurately and continuously localize the prostate target as existing motion tracking systems do, the present technique effectively uses cine-MV data to provide a clinically valuable way to minimize kV usage, while maintaining high targeting accuracy.

  11. Visual assessment of brain magnetic resonance imaging detects injury to cognitive regulatory sites in patients with heart failure.

    Science.gov (United States)

    Pan, Alan; Kumar, Rajesh; Macey, Paul M; Fonarow, Gregg C; Harper, Ronald M; Woo, Mary A

    2013-02-01

    Heart failure (HF) patients exhibit depression and executive function impairments that contribute to HF mortality. Using specialized magnetic resonance imaging (MRI) analysis procedures, brain changes appear in areas regulating these functions (mammillary bodies, hippocampi, and frontal cortex). However, specialized MRI procedures are not part of standard clinical assessment for HF (which is usually a visual evaluation), and it is unclear whether visual MRI examination can detect changes in these structures. Using brain MRI, we visually examined the mammillary bodies and frontal cortex for global and hippocampi for global and regional tissue changes in 17 HF and 50 control subjects. Significantly global changes emerged in the right mammillary body (HF 1.18 ± 1.13 vs control 0.52 ± 0.74; P = .024), right hippocampus (HF 1.53 ± 0.94 vs control 0.80 ± 0.86; P = .005), and left frontal cortex (HF 1.76 ± 1.03 vs control 1.24 ± 0.77; P = .034). Comparison of the visual method with specialized MRI techniques corroborates right hippocampal and left frontal cortical, but not mammillary body, tissue changes. Visual examination of brain MRI can detect damage in HF in areas regulating depression and executive function, including the right hippocampus and left frontal cortex. Visual MRI assessment in HF may facilitate evaluation of injury to these structures and the assessment of the impact of potential treatments for this damage. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Application of some pattern recognition methods for the early detection of failures at NPP components by means of noise diagnosis

    International Nuclear Information System (INIS)

    Weiss, F.P.

    1985-01-01

    The automation of the decisions on normality or abnormality of the plant condition being based on automated measurements is an essential step for the integration of noise diagnostics into the control and safety system of a nuclear power plant. By reason of the stochastic character of noise diagnostic measuring quantities principles of statistical pattern recognition are used in order automatically to get a decision on the plant condition. Four different pattern recognition methods complementing each other have been developed respectively tested with data from a WWER-440 type reactor. These four methods are included in a specially written software package. According to stationarity, correlation and probability distribution type of the state describing features and according to the necessary detection sensitivity to failures either the decorrelation method, the cluster method, the Parzen method or the distribution test of Wilcoxon, Mann and Whitney has to be applied. The efficiency and the limits of the investigated methods are discussed in detail. In context with the surveillance of the WWER-440 core by means of the power spectral densities of neutron flux fluctuations it could as well experimentally as theoretically be shown that the logarithmic power spectral densities follow a Gaussian probability distribution. (author)

  13. Predictors of treatment failure and time to detection and switching in HIV-infected Ethiopian children receiving first line anti-retroviral therapy

    Directory of Open Access Journals (Sweden)

    Bacha Tigist

    2012-08-01

    Full Text Available Abstract Background The emergence of resistance to first line antiretroviral therapy (ART regimen leads to the need for more expensive and less tolerable second line drugs. Hence, it is essential to identify and address factors associated with an increased probability of first line ART regimen failure. The objective of this article is to report on the predictors of first line ART regimen failure, the detection rate of ART regime failure, and the delay in switching to second line ART drugs. Methods A retrospective cohort study was conducted from 2005 to 2011. All HIV infected children under the age of 15 who took first line ART for at least six months at the four major hospitals of Addis Ababa, Ethiopia were included. Data were collected, entered and analyzed using Epi info/ENA version 3.5.1 and SPSS version 16. The Cox proportional-hazard model was used to assess the predictors of first line ART failure. Results Data of 1186 children were analyzed. Five hundred seventy seven (48.8% were males with a mean age of 6.22 (SD = 3.10 years. Of the 167(14.1% children who had treatment failure, 70 (5.9% had only clinical failure, 79 (6.7% had only immunologic failure, and 18 (1.5% had both clinical and immunologic failure. Patients who had height for age in the third percentile or less at initiation of ART were found to have higher probability of ART treatment failure [Adjusted Hazard Ratio (AHR, 3.25 95% CI, 1.00-10.58]. Patients who were less than three years old [AHR, 1.85 95% CI, 1.24-2.76], chronic diarrhea after initiation of antiretroviral treatment [AHR, 3.44 95% CI, 1.37-8.62], ART drug substitution [AHR, 1.70 95% CI, 1.05-2.73] and base line CD4 count below 50 cells/mm3 [AHR, 2.30 95% CI, 1.28-4.14] were also found to be at higher risk of treatment failure. Of all the 167 first line ART failure cases, only 24 (14.4% were switched to second line ART with a mean delay of 24 (SD = 11.67 months. The remaining 143 (85.6% cases were diagnosed

  14. Avoidance Behavior against Positive Allergens Detected with a Multiple Allergen Simultaneous Test Immunoblot Assay in Patients with Urticaria: Factors Associated with Avoidance Success/Failure.

    Science.gov (United States)

    Lee, Min Kyung; Kwon, In Ho; Kim, Han Su; Kim, Heung Yeol; Cho, Eun Byul; Bae, Youin; Park, Gyeong Hun; Park, Eun Joo; Kim, Kwang Ho; Kim, Kwang Joong

    2016-02-01

    Avoidance behavior against positive allergens detected by using multiple allergen simultaneous test (MAST)-immunoblot assay in patients with urticaria has been rarely reported. We aimed to assess the avoidance behavior of patients with urticaria against positive allergens detected with a MAST. One hundred and one urticaria patients who showed positivity to at least one allergen on a MAST completed a questionnaire regarding their test results. The avoidance behavior of the patients was evaluated, and relevant determining factors of avoidance success/failure were statistically assessed. We detected 144 different data (n=51, food allergens; n=17, pollen allergens; and n=76, aeroallergens) from 101 patients with urticaria. The avoidance failure rates were 33.3% for food allergens, 70.6% for pollen allergens, and 30.3% for aeroallergens. The pollen group showed a significantly higher avoidance failure rate than the food and aeroallergen groups (psuccessfully avoid allergens (psuccess or failure against allergens in patients with urticaria when clinicians conduct allergen-specific immunoglobulin E tests.

  15. Novel sensing approach for LPG leakage detection: Part II: Effects of particle size, composition and coating layer thickness

    KAUST Repository

    Mukhopadhyay, Subhas; Nag, Anindya; Zia, Asif; Li, Xie; Kosel, Jü rgen

    2015-01-01

    exhibits the optimization of the response time of the sensor by inhabiting characteristic changes like variation in the concentration of the dispersion medium, thickness of the coating and the size of the dispersed medium. Different concentrations

  16. Rapid detection of Cu(2+) by a paper-based microfluidic device coated with bovine serum albumin (BSA)-Au nanoclusters.

    Science.gov (United States)

    Fang, Xueen; Zhao, Qianqian; Cao, Hongmei; Liu, Juan; Guan, Ming; Kong, Jilie

    2015-11-21

    In this work, bovine serum albumin (BSA)-Au nanoclusters were used to coat a paper-based microfluidic device. This device acted as a Cu(2+) biosensor that showed fluorescence quenching on detection of copper ions. The detection limit of this sensor could be adjusted by altering the water absorbing capacity of the device. Qualitative and semi-quantitative results could be obtained visually without the aid of any advanced instruments. This sensor could test Cu(2+) rapidly with high specificity and sensitivity, which would be useful for point-of-care testing (POCT).

  17. Failure in the detection of the sentinel lymph node with a combined technique of radioactive tracer and blue dye in a patient with cancer of the vulva and a single positive lymph node

    NARCIS (Netherlands)

    Fons, G.; ter Rahe, B.; Sloof, G.; de Hullu, J.; van der Velden, J.

    2004-01-01

    Background. In early stage vulvar cancer, the sentinel lymph node procedure with a radioactive tracer appears to be a promising new diagnostic tool to predict lymph node status. No detection failures have been published so far in vulvar cancer. We recently experienced failure in the detection of the

  18. Failure in the detection of the sentinel lymph node with a combined technique of radioactive tracer and blue dye in a patient with cancer of the vulva and a single positive lymph node

    NARCIS (Netherlands)

    Fons, G; ter Rahe, B; Sloof, G; de Hullu, J; van der Velden, J

    Background. In early stage vulvar cancer, the sentinel lymph node procedure with a radioactive tracer appears to be a promising new diagnostic tool to predict lymph node status. No detection failures have been published so far in vulvar cancer. We recently experienced failure in the detection of the

  19. The internal model: A study of the relative contribution of proprioception and visual information to failure detection in dynamic systems. [sensitivity of operators versus monitors to failures

    Science.gov (United States)

    Kessel, C.; Wickens, C. D.

    1978-01-01

    The development of the internal model as it pertains to the detection of step changes in the order of control dynamics is investigated for two modes of participation: whether the subjects are actively controlling those dynamics or are monitoring an autopilot controlling them. A transfer of training design was used to evaluate the relative contribution of proprioception and visual information to the overall accuracy of the internal model. Sixteen subjects either tracked or monitored the system dynamics as a 2-dimensional pursuit display under single task conditions and concurrently with a sub-critical tracking task at two difficulty levels. Detection performance was faster and more accurate in the manual as opposed to the autopilot mode. The concurrent tracking task produced a decrement in detection performance for all conditions though this was more marked for the manual mode. The development of an internal model in the manual mode transferred positively to the automatic mode producing enhanced detection performance. There was no transfer from the internal model developed in the automatic mode to the manual mode.

  20. Signal sensitivity of alternating current potential drop measurement for crack detection of conductive substrate with tunable coating materials through finite element modeling

    International Nuclear Information System (INIS)

    Rao, Simha Sandeep; Zhao, Huijuan; Liu, Ming; Peng, Fei; Zhang, Bo

    2016-01-01

    We adopt a finite element numerical modeling approach to investigate the electromagnetic coupling effect of two parallel electric conductors with tunable electric conductivity σ and magnetic permeability μ . For two parallel conductors C and S ( μ C   ⋅  σ C   ≤  μ S   ⋅  σ S ), we find that the shape of current density profile of conductor S is dependent on the product of μ C   ⋅  σ C , while the magnitude is determined by the AC current frequency f . On the other hand, the frequency f affects not only the shape but also the magnitude of the current density profile of conductor C. We further adopt a coplanar model to investigate the signal sensitivity of alternating current potential drop (ACPD) measurement for both surface crack and inner crack detection. We find that with modified coating materials (lower electric conductivity and higher magnetic permeability, compared with the substrate material properties), the crack detection signal sensitivity can be greatly enhanced for both the cracks within the coating and at the coating/substrate interface, where cracks are most commonly encountered in real situations. (paper)

  1. Colloidal Gold Nanoclusters Spiked Silica Fillers in Mixed Matrix Coatings: Simultaneous Detection and Inhibition of Healthcare-Associated Infections

    KAUST Repository

    Alsaiari, Shahad K.; Hammami, Mohamed Amen; Croissant, Jonas G.; Omar, Haneen; Neelakanda, Pradeep; Yapici, Tahir; Peinemann, Klaus-Viktor; Khashab, Niveen M.

    2017-01-01

    Healthcare-associated infections (HAIs) are the infections that patients get while receiving medical treatment in a medical facility with bacterial HAIs being the most common. Silver and gold nanoparticles (NPs) have been successfully employed as antibacterial motifs; however, NPs leaching in addition to poor dispersion and overall reproducibility are major hurdles to further product development. In this study, the authors design and fabricate a smart antibacterial mixed-matrix membrane coating comprising colloidal lysozyme-templated gold nanoclusters as nanofillers in poly(ethylene oxide)/poly(butylene terephthalate) amphiphilic polymer matrix. Mesoporous silica nanoparticles-lysozyme functionalized gold nanoclusters disperse homogenously within the polymer matrix with no phase separation and zero NPs leaching. This mixed-matrix coating can successfully sense and inhibit bacterial contamination via a controlled release mechanism that is only triggered by bacteria. The system is coated on a common radiographic dental imaging device (photostimulable phosphor plate) that is prone to oral bacteria contamination. Variation and eventually disappearance of the red fluorescence surface under UV light signals bacterial infection. Kanamycin, an antimicrobial agent, is controllably released to instantly inhibit bacterial growth. Interestingly, the quality of the images obtained with these coated surfaces is the same as uncoated surfaces and thus the safe application of such smart coatings can be expanded to include other medical devices without compromising their utility.

  2. Colloidal Gold Nanoclusters Spiked Silica Fillers in Mixed Matrix Coatings: Simultaneous Detection and Inhibition of Healthcare-Associated Infections.

    Science.gov (United States)

    Alsaiari, Shahad K; Hammami, Mohammed A; Croissant, Jonas G; Omar, Haneen W; Neelakanda, Pradeep; Yapici, Tahir; Peinemann, Klaus-Viktor; Khashab, Niveen M

    2017-03-01

    Healthcare-associated infections (HAIs) are the infections that patients get while receiving medical treatment in a medical facility with bacterial HAIs being the most common. Silver and gold nanoparticles (NPs) have been successfully employed as antibacterial motifs; however, NPs leaching in addition to poor dispersion and overall reproducibility are major hurdles to further product development. In this study, the authors design and fabricate a smart antibacterial mixed-matrix membrane coating comprising colloidal lysozyme-templated gold nanoclusters as nanofillers in poly(ethylene oxide)/poly(butylene terephthalate) amphiphilic polymer matrix. Mesoporous silica nanoparticles-lysozyme functionalized gold nanoclusters disperse homogenously within the polymer matrix with no phase separation and zero NPs leaching. This mixed-matrix coating can successfully sense and inhibit bacterial contamination via a controlled release mechanism that is only triggered by bacteria. The system is coated on a common radiographic dental imaging device (photostimulable phosphor plate) that is prone to oral bacteria contamination. Variation and eventually disappearance of the red fluorescence surface under UV light signals bacterial infection. Kanamycin, an antimicrobial agent, is controllably released to instantly inhibit bacterial growth. Interestingly, the quality of the images obtained with these coated surfaces is the same as uncoated surfaces and thus the safe application of such smart coatings can be expanded to include other medical devices without compromising their utility. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Colloidal Gold Nanoclusters Spiked Silica Fillers in Mixed Matrix Coatings: Simultaneous Detection and Inhibition of Healthcare-Associated Infections

    KAUST Repository

    Alsaiari, Shahad K.

    2017-01-25

    Healthcare-associated infections (HAIs) are the infections that patients get while receiving medical treatment in a medical facility with bacterial HAIs being the most common. Silver and gold nanoparticles (NPs) have been successfully employed as antibacterial motifs; however, NPs leaching in addition to poor dispersion and overall reproducibility are major hurdles to further product development. In this study, the authors design and fabricate a smart antibacterial mixed-matrix membrane coating comprising colloidal lysozyme-templated gold nanoclusters as nanofillers in poly(ethylene oxide)/poly(butylene terephthalate) amphiphilic polymer matrix. Mesoporous silica nanoparticles-lysozyme functionalized gold nanoclusters disperse homogenously within the polymer matrix with no phase separation and zero NPs leaching. This mixed-matrix coating can successfully sense and inhibit bacterial contamination via a controlled release mechanism that is only triggered by bacteria. The system is coated on a common radiographic dental imaging device (photostimulable phosphor plate) that is prone to oral bacteria contamination. Variation and eventually disappearance of the red fluorescence surface under UV light signals bacterial infection. Kanamycin, an antimicrobial agent, is controllably released to instantly inhibit bacterial growth. Interestingly, the quality of the images obtained with these coated surfaces is the same as uncoated surfaces and thus the safe application of such smart coatings can be expanded to include other medical devices without compromising their utility.

  4. Environmental effect of S02-bearing atmosphere on the creep fatigue failure of aluminide-coated MM-002 nickel-base superalloy at 870°C

    CSIR Research Space (South Africa)

    Aghion, E

    1995-04-15

    Full Text Available stream_source_info Aghion_1995.pdf.txt stream_content_type text/plain stream_size 22555 Content-Encoding ISO-8859-1 stream_name Aghion_1995.pdf.txt Content-Type text/plain; charset=ISO-8859-1 JOURNAL OF" MATERIALS... Figure 1 Microstructure at a longitudinal cross-sectional specimen of coated MAR-M002 with spot chemical analysis of the different layers; etched. two parts, namely the gas mixing system and thermo- mechanical loading system. The specimen neck...

  5. Comparing the detection of iron-based pottery pigment on a carbon-coated sherd by SEM-EDS and by Micro-XRF-SEM.

    Science.gov (United States)

    Pendleton, Michael W; Washburn, Dorothy K; Ellis, E Ann; Pendleton, Bonnie B

    2014-03-01

    The same sherd was analyzed using a scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) and a micro X-ray fluorescence tube attached to a scanning electron microscope (Micro-XRF-SEM) to compare the effectiveness of elemental detection of iron-based pigment. To enhance SEM-EDS mapping, the sherd was carbon coated. The carbon coating was not required to produce Micro-XRF-SEM maps but was applied to maintain an unbiased comparison between the systems. The Micro-XRF-SEM analysis was capable of lower limits of detection than that of the SEM-EDS system, and therefore the Micro-XRF-SEM system could produce elemental maps of elements not easily detected by SEM-EDS mapping systems. Because SEM-EDS and Micro-XRF-SEM have been used for imaging and chemical analysis of biological samples, this comparison of the detection systems should be useful to biologists, especially those involved in bone or tooth (hard tissue) analysis.

  6. Application of Microwave Methods for Characterization of NEG Coatings and Obstacle Detection in Accelerator Beam-pipes

    CERN Document Server

    Seebacher, David

    2009-01-01

    In many particle accelerators, including the LHC at the European Organization for Nuclear Research CERN, NEG coatings are used to improve vacuum performance. In other particle accelerators there have been hints that those coatings could have a relevant impact on the beam coupling impedance, however the data available is contradictory. To clarify the possible impact of NEG coatings the electromagnetic properties have been measured. The measurements have been carried out by means of cavity perturbation method. The second part of this thesis deals with the microwave waveguide reflectometer developed at CERN several years ago, which is used as part of the quality assurance test program for the LHC assembly. To ensure optimum operation and to avoid an expensive removal of any foreign object from inside the LHC beam-screen after its completion, microwave reflectometry is performed. Until now several objects have been found by means of reflectometry, but so far neither precise data about the reflections of different...

  7. Launch Pad Coatings for Smart Corrosion Control

    Science.gov (United States)

    Calle, Luz M.; Hintze, Paul E.; Bucherl, Cori N.; Li, Wenyan; Buhrow, Jerry W.; Curran, Jerome P.; Whitten, Mary C.

    2010-01-01

    Corrosion is the degradation of a material as a result of its interaction with the environment. The environment at the KSC launch pads has been documented by ASM International (formerly American Society for Metals) as the most corrosive in the US. The 70 tons of highly corrosive hydrochloric acid that are generated by the solid rocket boosters during a launch exacerbate the corrosiveness of the environment at the pads. Numerous failures at the pads are caused by the pitting of stainless steels, rebar corrosion, and the degradation of concrete. Corrosion control of launch pad structures relies on the use of coatings selected from the qualified products list (QPL) of the NASA Standard 5008A for Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment. This standard was developed to establish uniform engineering practices and methods and to ensure the inclusion of essential criteria in the coating of ground support equipment (GSE) and facilities used by or for NASA. This standard is applicable to GSE and facilities that support space vehicle or payload programs or projects and to critical facilities at all NASA locations worldwide. Environmental regulation changes have dramatically reduced the production, handling, use, and availability of conventional protective coatings for application to KSC launch structures and ground support equipment. Current attrition rate of qualified KSC coatings will drastically limit the number of commercial off the shelf (COTS) products available for the Constellation Program (CxP) ground operations (GO). CxP GO identified corrosion detection and control technologies as a critical, initial capability technology need for ground processing of Ares I and Ares V to meet Constellation Architecture Requirements Document (CARD) CxP 70000 operability requirements for reduced ground processing complexity, streamlined integrated testing, and operations phase affordability

  8. Polyethylenimine-coated Fe3O4 nanoparticles effectively quench fluorescent DNA, which can be developed as a novel platform for protein detection.

    Science.gov (United States)

    Ma, Long; Sun, Nana; Zhang, Jinyan; Tu, Chunhao; Cao, Xiuqi; Duan, Demin; Diao, Aipo; Man, Shuli

    2017-11-23

    We report a novel assembly of polyethyleneimine (PEI)-coated Fe 3 O 4 nanoparticles (NPs) with single-stranded DNA (ssDNA), and the fluorescence of the dye labeled in the DNA is remarkably quenched. In the presence of a target protein, the protein-DNA aptamer mutual interaction releases the ssDNA from this assembly and hence restores the fluorescence. This feature could be adopted to develop an aptasensor for protein detection. As a proof-of-concept, for the first time, we have used this proposed sensing strategy to detect thrombin selectively and sensitively. Furthermore, simultaneous multiple detection of thrombin and lysozyme in a complex protein mixture has been proven to be possible.

  9. Transparent, flexible surface enhanced Raman scattering substrates based on Ag-coated structured PET (polyethylene terephthalate) for in-situ detection

    International Nuclear Information System (INIS)

    Zuo, Zewen; Zhu, Kai; Gu, Chuan; Wen, Yibing; Cui, Guanglei; Qu, Jun

    2016-01-01

    Highlights: • Transparent, flexible SERS substrates were prepared using techniques compatible with well-established silicon device technologies. • The SERS substrates exhibit high sensitivity and good reproducibility. • The high performance is related with the quasi-three-dimensional structure of the PET. • In-situ detection of analyte on irregular objects was achieved by this SERS substrate. - Abstract: Transparent, flexible surface-enhanced Raman scattering (SERS) substrates were fabricated by metalization of structured polyethylene terephthalate (PET) sheets. The resultant Ag-coated structured PET SERS substrates were revealed to be highly sensitive with good reproducibility and stability, an enhancement factor of 3 × 10 6 was acquired, which can be attributed mainly to the presence of plentiful multiple-type hot spots within the quasi-three-dimensional surface of the structured PET obtained by oxygen plasma etching. In addition, detections of model molecules on fruit skin were also carried out, demonstrating the great potential of the Ag-coated structured PET in in-situ detection of analyte on irregular objects. Importantly, the technique used for the preparation of such substrate is completely compatible with well-established silicon device technologies, and large-area fabrication with low cost can be readily realized.

  10. Transparent, flexible surface enhanced Raman scattering substrates based on Ag-coated structured PET (polyethylene terephthalate) for in-situ detection

    Energy Technology Data Exchange (ETDEWEB)

    Zuo, Zewen, E-mail: zuozewen@mail.ahnu.edu.cn; Zhu, Kai; Gu, Chuan; Wen, Yibing; Cui, Guanglei; Qu, Jun

    2016-08-30

    Highlights: • Transparent, flexible SERS substrates were prepared using techniques compatible with well-established silicon device technologies. • The SERS substrates exhibit high sensitivity and good reproducibility. • The high performance is related with the quasi-three-dimensional structure of the PET. • In-situ detection of analyte on irregular objects was achieved by this SERS substrate. - Abstract: Transparent, flexible surface-enhanced Raman scattering (SERS) substrates were fabricated by metalization of structured polyethylene terephthalate (PET) sheets. The resultant Ag-coated structured PET SERS substrates were revealed to be highly sensitive with good reproducibility and stability, an enhancement factor of 3 × 10{sup 6} was acquired, which can be attributed mainly to the presence of plentiful multiple-type hot spots within the quasi-three-dimensional surface of the structured PET obtained by oxygen plasma etching. In addition, detections of model molecules on fruit skin were also carried out, demonstrating the great potential of the Ag-coated structured PET in in-situ detection of analyte on irregular objects. Importantly, the technique used for the preparation of such substrate is completely compatible with well-established silicon device technologies, and large-area fabrication with low cost can be readily realized.

  11. A preliminary study of oxidation-resistant coatings on refractory-metal thermocouple sheaths

    International Nuclear Information System (INIS)

    Wilkins, S.C.

    1985-01-01

    The need to make reliable temperature measurements up to 2200 0 C or higher in steam environments during in-pile nuclear fuel damage tests led to a search for oxidation-resistant coatings for the refractory-metal sheaths used to enclose and protect thermocouples used for such measurements. Iridium, thoria, and thoria-over-iridium coatings were separately sputter-deposited on molybdenum-rhenium alloy protection tubes for evaluation. The coated samples were individually heated in flowing steam in an induction furnace. An extension tube welded to each sample was connected to a vacuum pump and gauge; failure of the sample was detected by noting the degradation of the vacuum maintained in the sample. Relatively heavy coatings of iridium provided a modest degree of oxidation protection at the temperatures of interest. Thoria coatings provided no significant protection at those temperatures, compared to uncoated control samples

  12. Radiographic detection of 100 A thickness variations in 1-μm-thick coatings applied to submillimeter-diameter laser fusion targets

    International Nuclear Information System (INIS)

    Stupin, D.M.

    1986-01-01

    We have developed x-ray radiography to measure thickness variations of coatings on laser fusion targets. Our technique is based on measuring the variation in x-ray transmission through the targets. The simplest targets are hollow glass microshells or microballoons 100 to 500 μm in diameter, that have several layers of metals or plastics, 1 to 100 μm thick. Our goal is to examine these opaque coatings for thickness variations as small as 1% or 0.1%, depending on the type of defect. Using contact radiography we have obtained the desired sensitivity for concentric and elliptical defects of 1%. This percentage corresponds to thickness variations as small as 100 A in a 1-μm-thick coating. For warts and dimples, the desired sensitivity is a function of the area of the defect, and we are developing a system to detect 0.1% thickness variations that cover an area 10 μm by 10 μm. We must use computer analysis of contact radiographs to measure 1% thickness variations in either concentricity or ellipticity. Because this analysis takes so long on our minicomputer, we preselect the radiographs by looking for defects at the 10% level on a video image analysis system

  13. Water-compatible graphene oxide/molecularly imprinted polymer coated stir bar sorptive extraction of propranolol from urine samples followed by high performance liquid chromatography-ultraviolet detection.

    Science.gov (United States)

    Fan, Wenying; He, Man; You, Linna; Zhu, Xuewei; Chen, Beibei; Hu, Bin

    2016-04-22

    Due to the high selectivity and stability, molecularly imprinted polymers (MIPs) have been successfully applied in stir bar sorptive extraction (SBSE) as a special coating to improve the selective extraction capability for target analytes. However, traditional MIPs usually suffer from incompatibility in aqueous media and low adsorption capacity, which limit the application of MIP coated stir bar in aqueous samples. To solve these problems, a water-compatible graphene oxides (GO)/MIP composite coated stir bar was prepared in this work by in situ polymerization. The prepared water-compatible GO/MIP coated stir bar presented good mechanical strength and chemical stability, and its recognition ability in aqueous samples was improved due to the polymerization of MIP in water environment, the adsorption capacity for target analytes was also increased by the addition of GO in MIP pre-polymer solution. Based on it, a method of water-compatible GO/MIP coated stir bar sorptive extraction combined with high performance liquid chromatography-ultraviolet detector (HPLV-UV) was proposed for the analysis of propranolol (PRO) in aqueous solution. The influencing factors of SBSE, such as sample pH, salt effect, stirring rate, extraction time, desorption solvent and desorption time, were optimized, and the analytical performance of the developed SBSE-HPLC-UV method was evaluated under the optimized conditions. The limit of detection (LOD) of the proposed method for PRO was about 0.37 μg L(-1), and the enrichment factor (EF) was 59.7-fold (theoretical EF was 100-fold). The reproducibility was also investigated at concentrations of 5 μg L(-1) and the relative standard deviation (RSD) was found to be 7.3% (n=7). The proposed method of GO/MIP coating-SBSE-HPLC-UV was successfully applied for the assay of the interested PRO drug in urine samples, and further extended to the investigation of the excretion of the drugs by monitoring the variation of the concentration of PRO in urine

  14. Development of a system for automatic detection of pellet failures; Desarrollo de un sistema para deteccion automatica de fallas en pastillas

    Energy Technology Data Exchange (ETDEWEB)

    Lavagnino, C E [Comision Nacional de Energia Atomica, San Martin (Argentina). Unidad de Actividad Combustibles Nucleares

    1997-12-31

    Nowadays, the failure controls in UO{sub 2} pellets for Atucha and Embalse reactors are performed visually. In this work it is presented the first stage of the development of a system that allows an automatic approach to the task. For this purpose, the problem has been subdivided in three jobs: choosing the illumination environment, finding the algorithm that detects failures with user-defined tolerance and engineering the mechanic system that supports the desired manipulations of the pellets. In this paper, the former two are developed. a) Finding the illumination conditions that allow subtracting the failure from the normal element surface, knowing, in first place, the cylindrical characteristics of it and, as a consequence, the differences in the light reflection direction and, in second place, the texture differences in relation to the rectification type of the pellet. b) Writing a fast and simple algorithm that allows the identification of the failure following the production specifications. Examples of the developed algorithm are shown. (author). 4 refs.

  15. Search for HRV-parameters that detect a sympathetic shift in heart failure patients on beta-blocker treatment

    NARCIS (Netherlands)

    Zhang, Yanru; de Peuter, Olav R.; Kamphuisen, Pieter W.; Karemaker, John M.

    2013-01-01

    Background: A sympathetic shift in heart rate variability (HRV) from high to lower frequencies may be an early signal of deterioration in a monitored patient. Most chronic heart failure (CHF) patients receive (3-blockers. This tends to obscure HRV observation by increasing the fast variations. We

  16. Failure mechanisms in high temperature gas cooled reactor fuel particles

    International Nuclear Information System (INIS)

    Soo, P.; Uneberg, G.; Sabatini, R.L.; Schweitzer, D.G.

    1979-01-01

    BISO coated UO 2 and ThO 2 particles were heated to high temperatures to determine failure mechanisms during hypothetical loss of coolant scenarios. Rapid failure begins when the oxides are reduced to liquid carbides. Several failure mechanisms are applicable, ranging from hole and crack formation in the coatings to catastrophic particle disintegration

  17. Polyaniline/cyclodextrin composite coated stir bar sorptive extraction combined with high performance liquid chromatography-ultraviolet detection for the analysis of trace polychlorinated biphenyls in environmental waters.

    Science.gov (United States)

    Lei, Yun; He, Man; Chen, Beibei; Hu, Bin

    2016-04-01

    A novel polyaniline/α-cyclodextrin (PANI/α-CD) composite coated stir bar was prepared by sol-gel process for the analysis of polychlorinated biphenyls (PCBs) in this work. The preparation reproducibility of the PANI/α-CD-coated stir bar was good, with relative standard deviations (RSDs) ranging from 2.3% to 3.7% (n=7) and 2.0% to 3.8% (n=7) for bar to bar and batch to batch, respectively. Based on it, a novel method of PANI/α-CD-coated stir bar sorptive extraction (SBSE) followed by high performance liquid chromatography-ultraviolet (HPLC-UV) detection was developed for the determination of trace PCBs in environmental waters. To obtain the best extraction performance for target PCBs, several parameters affecting SBSE, such as extraction time, stirring rate, and ionic strength were investigated. Under optimal experimental conditions, the limits of detection (LODs) of the proposed method for seven PCBs were in the range of 0.048-0.22 μg/L, and the RSDs were 5.3-9.8% (n=7, c=1 μg/L). Enrichment factors (EFs) ranging from 39.8 to 68.4-fold (theoretical EF, 83.3-fold) for target analytes were achieved. The proposed method was successfully applied for the determination of seven target PCBs in Yangtze River water and East Lake water, and the recoveries were in the range of 73.0-120% for the spiked East Lake water samples and 82.7-121% for the spiked Yangtze River water samples, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Determination of nitrite, nitrate, bromide, and iodide in seawater by ion chromatography with UV detection using dilauryldimethylammonium-coated monolithic ODS columns and sodium chloride as an eluent.

    Science.gov (United States)

    Ito, Kazuaki; Nomura, Ryosuke; Fujii, Takuya; Tanaka, Masahito; Tsumura, Tomoaki; Shibata, Hiroyuki; Hirokawa, Takeshi

    2012-11-01

    A method was developed for determination of inorganic anions, including nitrite (NO(2)(-)), nitrate (NO(3)(-)), bromide (Br(-)), and iodide (I(-)), in seawater by ion chromatography (IC). The IC system used two dilauryldimethylammonium bromide (DDAB)-coated monolithic ODS columns (50 × 4.6 mm i.d. and 100 × 4.6 mm i.d.) connected in series for separation of the ions. Aqueous NaCl (0.5 mol/L; flow rate, 3 mL/min) containing 5 mmol/L phosphate buffer (pH 5) was used as the eluent, and detection was with a UV detector at 225 nm. The monolithic ODS columns were coated and equilibrated with a 1-mmol/L DDAB solution (in H(2)O/methanol, 90:10 v/v). The hydrophilic ions (NO(2)(-), NO(3)(-), and Br(-)) were separated within 3 min and the retention time of I(-) was 16 min. No interferences from matrix ions, such as chloride and sulfate ions, were observed in 35 ‰ artificial seawater. The detection limits were 0.6 μg/L for NO(2)(-), 1.1 μg/L for NO(3)(-), 70 μg/L for Br(-), and 1.6 μg/L for I(-) with a 200-μL sample injection. The performance of the coated columns was maintained without addition of DDAB in the eluent. The IC system was successfully applied to real seawater samples with recovery rates of 94-108 % for all ions.

  19. Synthesis of surface molecular imprinting polymer on SiO{sub 2}-coated CdTe quantum dots as sensor for selective detection of sulfadimidine

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Zhiping; Ying, Haiqin; Liu, Yanyan [School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013 (China); Xu, Wanzhen, E-mail: xwz09@ujs.edu.cn [School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013 (China); Yang, Yanfei; Luan, Yu [Zhenjiang Institute for Drug Control of Jiangsu Province, Zhenjiang 212003 (China); Lu, Yi; Liu, Tianshu [Zhenjiang Entry-Exit Inspection Quarantine Bureau, Zhenjiang 212008 (China); Yu, Shui [School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013 (China); Yang, Wenming, E-mail: ywm@ujs.edu.cn [School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013 (China)

    2017-05-15

    Highlights: • Surface molecular imprinting technology and SiO{sub 2}-coated CdTe QDs were combined to prepare a novel fluorescent sensor for selective detection of sulfadimidine. • The relative fluorescent intensity weakened in a linear way with the increasing concentration of sulfadimidine in the range of 10–60 μmol L{sup −1}. • The practical application of the fluorescent MIP sensor was evaluated by means of analyzing sulfadimidine in the real milk samples. The recoveries were at the range of 90.3–99.6% and the relative standard deviation ranged from 1.9 to 3.1%. - Abstract: This paper demonstrates a facile method to synthesize surface molecular imprinting polymer (MIP) on SiO{sub 2}-coated CdTe QDs for selective detection of sulfadimidine (SM{sub 2}). The fluorescent MIP sensor was prepared using cadmium telluride quantum dots (CdTe QDs) as the material of fluorescent signal readout, sulfadimidine as template molecule, 3-aminopropyltriethoxysilane (APTES) as functional monomer and tetraethyloxysilane (TEOS) as cross-linking agent. The CdTe cores were embed in the silicon shells by a sol-gel reaction and then the molecular imprinting layers were immobilized on the surface of the SiO{sub 2}-coated CdTe QDs. Under the optimized conditions, the relative fluorescent intensity weakened in a linear way with the increasing concentration of sulfadimidine in the range of 10–60 μmol L{sup −1}. The practical application of the fluorescent MIP sensor was evaluated by means of analyzing sulfadimidine in the real milk samples. The recoveries were at the range of 90.3–99.6% and the relative standard deviation (RSD) ranged from 1.9 to 3.1%, which indicates the successful synthesis of the fluorescent MIP sensor. This sensor provides an alternative solution for selective determination of sulfadimidine from real milk samples.

  20. Using medical imaging for the detection of adverse events ("incidents") during the utilization of left ventricular assist devices in adult patients with advanced heart failure.

    Science.gov (United States)

    Kaufmann, Friedrich; Krabatsch, Thomas

    2016-05-01

    Ventricular assist devices (VAD) are used for mechanical support of the terminally failing heart. Failure of these life supporting systems can be fatal. Early and reliable detection of any upcoming problems is mandatory and is crucial for the outcome. Medical imaging methods are described within this review, which are not only essential for diagnosis of typically VAD-related complications but also for the detection or verification of technical issues. Within this review the utilization of medical imaging equipment for the diagnosis of technical malfunctions or damages of implanted system components is discussed. A newly developed specialized acoustic imaging method for pump thrombosis detection will also be described along with the most common VAD-related medical complications and their respective imaging methods and the limitations induced by the use of the VAD-system.

  1. Performance of a polymer coated silicon microarray for simultaneous detection of food allergen-specific IgE and IgG4.

    Science.gov (United States)

    Sievers, S; Cretich, M; Gagni, P; Ahrens, B; Grishina, G; Sampson, H A; Niggemann, B; Chiari, M; Beyer, K

    2017-08-01

    Microarray-based component-resolved diagnostics (CRD) has become an accepted tool to detect allergen-specific IgE sensitization towards hundreds of allergens in parallel from one drop of serum. Nevertheless, specificity and sensitivity as well as a simultaneous detection of allergen-specific IgG 4 , as a potential parameter for tolerance development, remain to be optimized. We applied the recently introduced silicon chip coated with a functional polymer named copoly(DMA-NAS-MAPS) to the simultaneous detection of food allergen-specific IgE and IgG 4 , and compared it with ImmunoCAP and ImmunoCAP ISAC. Inter- and intraslide variation, linearity of signal and working range, sensitivity and application of internal calibrations for IgE and IgG 4 were assessed. Native and recombinant allergenic proteins from hen's egg and cow's milk were spotted on silicon chips coated with copoly(DMA-NAS-MAPS) along with known concentrations for human IgE and IgG 4 . A serum pool and 105 patient samples were assessed quantitatively and semi-quantitatively with the ImmunoCAP and ImmunoCAP ISAC and correlated with IgE- and IgG 4 -specific fluorescence on silicon microarrays. Allergen-specific IgE and IgG 4 were detected in parallel using two fluorescent dyes with no crosstalk. Results from the ImmunoCAP correlated better with microarray fluorescence than with ImmunoCAP ISAC except for the allergen ovomucoid. The working range of the silicon microarray for total hen's egg-specific IgE was comparable to the range of 0.1 to >100 kU A /L of the ImmunoCAP system, whereas for total cow's milk, the silicon microarray was less sensitive. Detectable allergen-specific IgG 4 could be determined only for low concentrations, but still correlated positively with ImmunoCAP results. We confirmed the ability of the polymer coated silicon microarray to be comparably sensitive to the ImmunoCAP ISAC for various food allergens. This suggests that the copoly(DMA-NAS-MAPS) microarray is a low-cost, self

  2. Automotive component failures

    CSIR Research Space (South Africa)

    Heyes, AM

    1998-06-01

    Full Text Available in service for approximately 19\\999 km[ 1[1[ Visual examination Upon stripping the engine it was found that one of the combustion chambers showed heavy carbonaceous deposits indicative of the burning of oil "Fig[ 2# Circumferential black marks were found... whether failures in other vehicles could be expected[ 2[1[ Visual and stereo microscope examination The section of torsion bar submitted for examination was coated with a black paint coating which had ~aked o} at localised spots\\ where light rusting had...

  3. Polydimethylsiloxane/covalent triazine frameworks coated stir bar sorptive extraction coupled with high performance liquid chromatography-ultraviolet detection for the determination of phenols in environmental water samples.

    Science.gov (United States)

    Zhong, Cheng; He, Man; Liao, Huaping; Chen, Beibei; Wang, Cheng; Hu, Bin

    2016-04-08

    In this work, covalent triazine frameworks (CTFs) were introduced in stir bar sorptive extraction (SBSE) and a novel polydimethylsiloxane(PDMS)/CTFs stir bar coating was prepared by sol-gel technique for the sorptive extraction of eight phenols (including phenol, 2-chlorophenol, 2-nitrophenol, 4-nitrophenol, 2,4-dimethylphenol, p-chloro-m-cresol and 2,4-dichlorophenol, 2,4,6-trichlorophenol) from environmental water samples followed by high performance liquid chromatography-ultraviolet (HPLC-UV) detection. The prepared PDMS/CTFs coated stir bar showed good preparation reproducibility with the relative standard deviations (RSDs) ranging from 3.5 to 5.7% (n=7) in one batch, and from 3.7 to 9.3% (n=7) among different batches. Several parameters affecting SBSE of eight target phenols including extraction time, stirring rate, sample pH, ionic strength, desorption solvent and desorption time were investigated. Under the optimal experimental conditions, the limits of detection (LODs, S/N=3) were found to be in the range of 0.08-0.30 μg/L. The linear range was 0.25-500 μg/L for 2-nitrophenol, 0.5-500 μg/L for phenol, 2-chlorophenol, 4-nitrophenol as well as 2,4-dimethylphenol, and 1-500 μg/L for p-chloro-m-cresol, 2,4-dichlorophenol as well as 2,4,6-trichlorophenol, respectively. The intra-day relative standard deviations (RSDs) were in the range of 4.3-9.4% (n=7, c=2 μg/L) and the enrichment factors ranged from 64.9 to 145.6 fold (theoretical enrichment factor was 200-fold). Compared with commercial PDMS coated stir bar (Gerstel) and PEG coated stir bar (Gerstel), the prepared PDMS/CTFs stir bar showed better extraction efficiency for target phenol compounds. The proposed method was successfully applied to the analysis of phenols in environmental water samples and good relative recoveries were obtained with the spiking level at 2, 10, 50 μg/L, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Controlled deposition of functionalized silica coated zinc oxide nano-assemblies at the air/water interface for blood cancer detection

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Chandra Mouli [Biomedical Instrumentation Section, CSIR-National Physical Laboratory, New Delhi 110012 (India); Nanobioelectronics Laboratory, Department of Biotechnology, Delhi Technological University, Delhi 110042 (India); Dewan, Srishti [Biomedical Instrumentation Section, CSIR-National Physical Laboratory, New Delhi 110012 (India); Biomedical Engineering Department, Deenbandhu Chhotu Ram University of Science & Technology, Haryana 131039 (India); Chawla, Seema [Biomedical Engineering Department, Deenbandhu Chhotu Ram University of Science & Technology, Haryana 131039 (India); Yadav, Birendra Kumar [Rajiv Gandhi Cancer Institute and Research Centre, Rohini, Delhi 110085 (India); Sumana, Gajjala, E-mail: sumanagajjala@gmail.com [Biomedical Instrumentation Section, CSIR-National Physical Laboratory, New Delhi 110012 (India); Malhotra, Bansi Dhar, E-mail: bansi.malhotra@gmail.com [Biomedical Instrumentation Section, CSIR-National Physical Laboratory, New Delhi 110012 (India); Nanobioelectronics Laboratory, Department of Biotechnology, Delhi Technological University, Delhi 110042 (India)

    2016-09-21

    We report results of the studies relating to controlled deposition of the amino-functionalized silica-coated zinc oxide (Am-Si@ZnO) nano-assemblies onto an indium tin oxide (ITO) coated glass substrate using Langmuir-Blodgett (LB) technique. The monolayers have been deposited by transferring the spread solution of Am-Si@ZnO stearic acid prepared in chloroform at the air-water interface, at optimized pressure (16 mN/m), concentration (10 mg/ml) and temperature (23 °C). The high-resolution transmission electron microscopic studies of the Am-Si@ZnO nanocomposite reveal that the nanoparticles have a microscopic structure comprising of hexagonal assemblies of ZnO with typical dimensions of 30 nm. The surface morphology of the LB multilayer observed by scanning electron microscopy shows uniform surface of the Am-Si@ZnO film in the nanometer range (<80 nm). These electrodes have been utilized for chronic myelogenous leukemia (CML) detection by covalently immobilizing the amino-terminated oligonucleotide probe sequence via glutaraldehyde as a crosslinker. The response studies of these fabricated electrodes carried out using electrochemical impedance spectroscopy show that this Am-Si@ZnO LB film based nucleic acid sensor exhibits a linear response to complementary DNA (10{sup −6}–10{sup −16} M) with a detection limit of 1 × 10{sup −16} M. This fabricated platform is validated with clinical samples of CML positive patients and the results demonstrate its immense potential for clinical diagnosis. - Graphical abstract: Controlled deposition of functionalized silica coated zinc oxide nano-assemblies at the air/water interface for label free electrochemical detection of chronic myelogenous leukemia. - Highlights: • Stable and controlled deposition of Am-Si@ZnO nano-assemblies using LB technique. • Uniform monolayer deposition of the Am-Si@ZnO LB film within the nanometer range. • Am-Si@ZnO LB film shows enhanced electrochemical properties. • Fabricated

  5. Failure of pheromone traps in detecting incipient populations of boll weevils (Coleoptera: Curculionidae): Investigation of two potential contributing factors

    Science.gov (United States)

    Progress towards complete eradication of the boll weevil has been delayed in some areas of Texas due to the inconsistent performance of pheromone traps in detecting incipient weevil populations. In 2008 substantial infestations of boll weevils, Anthonomus grandis Boheman, were detected in several c...

  6. Synthesis of Colloidal Quantum Dots Coated with Mercaptosuccinic Acid for Early Detection and Therapeutics of Oral Cancers

    Science.gov (United States)

    Jocelin, G.; Arivarasan, A.; Ganesan, M.; Prasad, N. Rajendra; Sasikala, G.

    2016-04-01

    Quantum dots (QDs) are gaining widespread recognition for its luminescence behavior and unique photo physical properties as a bio-marker and inorganic fluorophore. In spite of such rampant advantages, its application is clinically hampered depending on the surface coating decreasing its luminescence efficiency. The present study reports preparation of CdTe QDs capped with biologically active thiol based material, mercaptosuccinic acid (MSA) for diagnosis of oral cancer (KB) cells by acting as a fluorophore marking targeted tumor cells and at the same time exhibiting certain cytotoxic effects. Synthesized MSA coated CdTe QDs is spherical in shape with an average particle size of 3-5nm. In vitro, the rapid uptake of MSA CdTe QDs in oral cancer cell lines were assessed through fluorescence microscopy. Further, this study evaluates the therapeutic efficiency of MSA CdTe QDs in human oral cancer cell lines using MTT analysis. MSA CdTe QDs exhibit significant cytotoxicity in oral cancer cells in a dose dependent manner with low IC50 when compared with other raw CdTe QDs. MSA CdTe QDs were also treated with human lymphocytes (normal cells) to assess and compare the toxicity profile of QDs in normal and oral tumors. The results of our present study strengthen our hypothesis of using MSA CdTe QDs as detector for tracking and fluorescence imaging of oral cancer cells and exhibiting sufficient cytotoxicity in them.

  7. Coating thickness measuring device

    International Nuclear Information System (INIS)

    Joffe, B.B.; Sawyer, B.E.; Spongr, J.J.

    1984-01-01

    A device especially adapted for measuring the thickness of coatings on small, complexly-shaped parts, such as, for example, electronic connectors, electronic contacts, or the like. The device includes a source of beta radiation and a radiation detector whereby backscatter of the radiation from the coated part can be detected and the thickness of the coating ascertained. The radiation source and detector are positioned in overlying relationship to the coated part and a microscope is provided to accurately position the device with respect to the part. Means are provided to control the rate of descent of the radiation source and radiation detector from its suspended position to its operating position and the resulting impact it makes with the coated part to thereby promote uniformity of readings from operator to operator, and also to avoid excessive impact with the part, thereby improving accuracy of measurement and eliminating damage to the parts

  8. Chemical speciation of arsenic species in human blood serum by liquid chromatography using a phosphatidylcholine-coated ODS column with detection by ICP-MS

    International Nuclear Information System (INIS)

    Hasegawa, Takuya; Ishise, Jotaro; Fukumoto, Yasuharu; Matsuura, Hirotaka; Zhu, Yanbei; Umemura, Tomonari; Haraguchi, Hiroki; Yamamoto, Kazuhito; Naoe, Tomoki

    2007-01-01

    Chemical speciation of arsenic species in human blood serum was performed by high-performance liquid chromatography/inductively coupled plasma mass spectrometry (HPLC/ICP-MS) with direct sample injection, where an octadecylsilyl silica (ODS) column coated with phosphatidylcholine (PC) (hereafter known as 'PC-coated ODS column') was used as the separation column. In arsenic species analysis, a citrate buffer solution (pH 4.0) was used as the mobile phase, in which the following reagents were added: sodium 1-dodecanesulfonate (SDS), tetramethylammonium hydroxide (TMAH), which are ion-pair reagents to separate inorganic and organic arsenic species, and 3-[(3-cholamidopropyl)-dimethylammonio]-1-propane sulfonate (CHAPS), which is a protein-solubilizing agent to prevent adsorption of proteins on the column. As a result of optimization, five representative arsenic species spiked in human blood serum reference material could be separated from each other within 5 min on the PC-coated ODS column by elution with a 5 mM citrate buffer (pH 4.0) containing 5 mM SDS, 5 mM THAH, and 0.2 mM CHAPS. The detection limits obtained by ICP-MS were 3.1, 2.7, 4.5, 2.5, and 2.5 ng of As g -1 for arsenate (iAs V ), arsenite (iAs III ), monomethylarsonic acid (MMA), dimethylarsenic acid (DMA), and arsenobetaine (AB), respectively, when the injection volume was 20 μL. The present separation system was also applied to speciation analysis of arsenic species in human blood serum collected from a leukemia patient after therapeutic treatment with arsenic. (author)

  9. Using DR52c/Ni2+ mimotope tetramers to detect Ni2+ reactive CD4+ T cells in patients with joint replacement failure.

    Science.gov (United States)

    Zhang, Yan; Wang, Yang; Anderson, Kirsten; Novikov, Andrey; Liu, Zikou; Pacheco, Karin; Dai, Shaodong

    2017-09-15

    T cell mediated hypersensitivity to nickel (Ni 2+ ) is one of the most common causes of allergic contact dermatitis. Ni 2+ sensitization may also contribute to the failure of Ni 2+ containing joint implants, and revision to non-Ni 2+ containing hardware can be costly and debilitating. Previously, we identified Ni 2+ mimotope peptides, which are reactive to a CD4 + T cell clone, ANi2.3 (Vα1, Vβ17), isolated from a Ni 2+ hypersensitive patient with contact dermatitis. This T cell is restricted to the major histocompatibility complex class II (MHCII) molecule, Human Leukocyte Antigen (HLA)-DR52c (DRA, DRB3*0301). However, it is not known if Ni 2+ induced T cell responses in sensitized joint replacement failure patients are similar to subjects with Ni 2+ induced contact dermatitis. Here, we generated DR52c/Ni 2+ mimotope tetramers, and used them to test if the same Ni 2+ T cell activation mechanism could be generalized to Ni 2+ sensitized patients with associated joint implant failure. We confirmed the specificity of these tetramers by staining of ANi2.3T cell transfectomas. The DR52c/Ni 2+ mimotope tetramer detected Ni 2+ reactive CD4 + T cells in the peripheral blood mononuclear cells (PBMC) of patients identified as Ni 2+ sensitized by patch testing and a positive Ni 2+ LPT. When HLA-typed by a DR52 specific antibody, three out of four patients were DR52 positive. In one patient, Ni 2+ stimulation induced the expansion of Vβ17 positive CD4 + T cells from 0.8% to 13.3%. We found that the percentage of DR52 positivity and Vβ17 usage in Ni 2+ sensitized joint failure patients are similar to Ni sensitized skin allergy patients. Ni 2+ independent mimotope tetramers may be a useful tool to identify the Ni 2+ reactive CD4 + T cells. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. A geometric approach for fault detection and isolation of stator short circuit failure in a single asynchronous machine

    KAUST Repository

    Khelouat, Samir; Benalia, Atallah; Boukhetala, Djamel; Laleg-Kirati, Taous-Meriem

    2012-01-01

    in nonlinear systems, we will study some structural properties which are fault detectability and isolation fault filter existence. We will then design filters for residual generation. We will consider two approaches: a two-filters structure and a single filter

  11. A Multifunctional Smart Coating for Autonomous Corrosion Control

    Science.gov (United States)

    Calle, Luz Marina; Buhrow, Jerry W.; Jolley, Scott T.

    2012-01-01

    Corrosion is a destructive process that often causes failure in metallic components and structures. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to control it. The multi-functionality of the coating is based on micro-encapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of other existing microcapsules designs, the corrosion controlled release function that allows the delivery of corrosion indicators and inhibitors on demand only when and where needed. Corrosion indicators as well as corrosion inhibitors have been incorporated into microcapsules, blended into several paint systems, and tested for corrosion detection and protection efficacy. This

  12. Thermal Shock Property of Al/Ni-ZrO2 Gradient Thermal Barrier Coatings

    Institute of Scientific and Technical Information of China (English)

    FANJin-juan; WANGQuan-sheng; ZHANGWei-fang

    2004-01-01

    Al/Ni-ZrO2 gradient thermal barrier coatings are made on aluminum substrate using plasma spraying method and one direction thermal shock properties of the coatings are studied in this paper. The results show that pores in coatings link to form cracks vertical to coating surface. They go through the whole ZrO2 coating once vertical cracks form. When thermal shock cycles increase, horizontal cracks that result in coatings failure forms in the coatings and interface. And vertical cracks delay appearance of horizontal cracks and enhance thermal shock property of coatings. Failure mechanisms of coating thermal shock are discussed using experiments and finite element method.

  13. Failure to detect seasonal changes in the song system nuclei of the black-capped chickadee (Poecile atricapillus).

    Science.gov (United States)

    Smulders, T V; Lisi, M D; Tricomi, E; Otter, K A; Chruszcz, B; Ratcliffe, L M; DeVoogd, T J

    2006-08-01

    Most temperate songbird species sing seasonally, and the brain areas involved in producing song (the song system) vary in size alongside the changes in behavior. Black-capped chickadees (Poecile atricapillus) also sing seasonally, and we find that there are changes in the stereotypy and the length of the fee-bee song from the nonbreeding to the breeding season. Yet despite these changes, we fail to find any evidence of seasonal changes in the song system. The song system of males is larger than that of females, as is typical in songbirds, but the ratio between the sexes is small compared to other species. We suggest three hypotheses to explain our failure to find seasonal variation in the chickadee song system.

  14. Quartz Crystal Microbalance Coated with Sol-gel-derived Thin Films as Gas Sensor for NO Detection

    Directory of Open Access Journals (Sweden)

    S. J. O’Shea

    2003-10-01

    Full Text Available This paper presents the possibilities and properties of Indium tin oxide (ITO-covered quartz crystal as a NOx toxic gas-sensor. The starting sol-gel solution was prepared by mixing indium chloride dissolved in acetylacetone and tin chloride dissolved in ethanol (0-20% by weight. The ITO thin films were deposited on the gold electrodes of quartz crystal by spin-coating technique and subsequently followed a standard photolithography to pattern the derived films to ensure all sensors with the same sensing areas. All heat treatment processes were controlled below 500°C in order to avoid the piezoelectric characteristics degradation of quartz crystal (Quartz will lose its piezoelectricity at ~573°C due to the phase change from α to β. The electrical and structural properties of ITO thin films were characterized with Hall analysis system, TG/DTA, XRD, XPS, SEM and etc. The gas sensor had featured with ITO thin films of ~100nm as the receptor to sense the toxic gas NO and quartz crystal with frequency of 10MHz as the transducer to transfer the surface reactions (mass loading, etc into the frequency shift. A homemade setup had been employed to measure the sensor response under the static mode. The experimental results had indicated that the ITO-coated QCM had a good sensitivity for NO gas, ~12Hz/100ppm within 5mins. These results prove that the ITO-covered quartz crystals are usable as a gas sensor and as an analytical device.

  15. Associations between inadequate knee function detected by KOOS and prospective graft failure in an anterior cruciate ligament-reconstructed knee.

    Science.gov (United States)

    Granan, Lars-Petter; Baste, Valborg; Engebretsen, Lars; Inacio, Maria C S

    2015-04-01

    First, to evaluate whether the 2 year post-operative Knee injury and Osteoarthritis Outcome Score (KOOS) in primary anterior cruciate ligament reconstructions (ACLRs) was significantly different between patients that did not go on to have a subsequent revision after the 2 year post-operative control and the ones that did. Second, to test whether the "clinically failure" value of KOOS quality of life (QoL) < 44 was indicative of a clinically relevant difference in the risk of subsequent revision ACLR. ACLRs reported to the Norwegian Knee Ligament Registry between June 2004 and December 2009. 5,517 primary ACLRs with at least 2-year follow-up with KOOS QoL before revision surgery. There were clinically significant differences, adjusted and unadjusted, in both the KOOS Sport and Recreation and QoL subscales in patients with a later revision surgery compared to those that did not have a revision surgery. In adjusted models, the risk of later ACLR revision was 3.7 (95 % CI 2.2-6.0) higher in patients with a 2-year KOOS QoL < 44 compared to patients with a KOOS QoL ≥ 44. For every 10-point reduction in the KOOS QoL, a 33.6 % (95 % CI 21.2-47.5 %) higher risk for later ACLR revision was observed. This study reveals an association between inadequate knee function, as measured by KOOS, and a prospective ACL-reconstructed graft failure. Prognostic study (prospective cohort study), Level II.

  16. Colorimetric gas detection by the varying thickness of a thin film of ultrasmall PTSA-coated TiO2 nanoparticles on a Si substrate

    Directory of Open Access Journals (Sweden)

    Urmas Joost

    2017-01-01

    Full Text Available Colorimetric gas sensing is demonstrated by thin films based on ultrasmall TiO2 nanoparticles (NPs on Si substrates. The NPs are bound into the film by p-toluenesulfonic acid (PTSA and the film is made to absorb volatile organic compounds (VOCs. Since the color of the sensing element depends on the interference of reflected light from the surface of the film and from the film/silicon substrate interface, colorimetric detection is possible by the varying thickness of the NP-based film. Indeed, VOC absorption causes significant swelling of the film. Thus, the optical path length is increased, interference wavelengths are shifted and the refractive index of the film is decreased. This causes a change of color of the sensor element visible by the naked eye. The color response is rapid and changes reversibly within seconds of exposure. The sensing element is extremely simple and cheap, and can be fabricated by common coating processes.

  17. Total inorganic arsenic detection in real water samples using anodic stripping voltammetry and a gold-coated diamond thin-film electrode.

    Science.gov (United States)

    Song, Yang; Swain, Greg M

    2007-06-12

    An accurate method for total inorganic arsenic determination in real water samples was developed using differential pulse anodic stripping voltammetry (DPASV) and a Au-coated boron-doped diamond thin-film electrode. Keys to the method are the use of a conducting diamond platform and solid phase extraction for sample preparation. In the method, the As(III) present in the sample is first detected by DPASV. The As(V) present is then reduced to As(III) by reaction with Na2SO3 and this is followed by a second detection of As(III) by DPASV. Interfering metal ions (e.g., Cu(II)) that cause decreased electrode response sensitivity for arsenic in real samples are removed by solid phase extraction as part of the sample preparation. For example, Cu(II) caused a 30% decrease in the As stripping peak current at a solution concentration ratio of 3:1 (Cu(II)/As(III)). This loss was mitigated by passage of the solution through a Chelex 100 cation exchange resin. After passage, only a 5% As stripping current response loss was seen. The effect of organic matter on the Au-coated diamond electrode response for As(III) was also evaluated. Humic acid at a 5 ppm concentration caused only a 9% decrease in the As stripping peak charge for Au-coated diamond. By comparison, a 50% response decrease was observed for Au foil. Clearly, the chemical properties of the diamond surface in the vicinity of the metal deposits inhibit molecular adsorption on at least some of the Au surface. The method provided reproducible and accurate results for total inorganic arsenic in two contaminated water samples provided by the U.S. Bureau of Reclamation. The total inorganic As concentration in the two samples, quantified by the standard addition method, was 23.2+/-2.9 ppb for UV plant influent water and 16.4+/-0.9 ppb for Well 119 water (n=4). These values differed from the specified concentrations by less than 4%.

  18. Total inorganic arsenic detection in real water samples using anodic stripping voltammetry and a gold-coated diamond thin-film electrode

    International Nuclear Information System (INIS)

    Song Yang; Swain, Greg M.

    2007-01-01

    An accurate method for total inorganic arsenic determination in real water samples was developed using differential pulse anodic stripping voltammetry (DPASV) and a Au-coated boron-doped diamond thin-film electrode. Keys to the method are the use of a conducting diamond platform and solid phase extraction for sample preparation. In the method, the As(III) present in the sample is first detected by DPASV. The As(V) present is then reduced to As(III) by reaction with Na 2 SO 3 and this is followed by a second detection of As(III) by DPASV. Interfering metal ions (e.g., Cu(II)) that cause decreased electrode response sensitivity for arsenic in real samples are removed by solid phase extraction as part of the sample preparation. For example, Cu(II) caused a 30% decrease in the As stripping peak current at a solution concentration ratio of 3:1 (Cu(II)/As(III)). This loss was mitigated by passage of the solution through a Chelex 100 cation exchange resin. After passage, only a 5% As stripping current response loss was seen. The effect of organic matter on the Au-coated diamond electrode response for As(III) was also evaluated. Humic acid at a 5 ppm concentration caused only a 9% decrease in the As stripping peak charge for Au-coated diamond. By comparison, a 50% response decrease was observed for Au foil. Clearly, the chemical properties of the diamond surface in the vicinity of the metal deposits inhibit molecular adsorption on at least some of the Au surface. The method provided reproducible and accurate results for total inorganic arsenic in two contaminated water samples provided by the U.S. Bureau of Reclamation. The total inorganic As concentration in the two samples, quantified by the standard addition method, was 23.2 ± 2.9 ppb for UV plant influent water and 16.4 ± 0.9 ppb for Well 119 water (n = 4). These values differed from the specified concentrations by less than 4%

  19. Physicochemical Properties of Calcium Phosphate Based Coating on Gutta-Percha Root Canal Filling

    Directory of Open Access Journals (Sweden)

    Afaf Al-Haddad

    2015-01-01

    Full Text Available Dental Gutta-percha (GP is a polymer based standard root canal filling material that has been widely used in dentistry. However, it has an inadequate sealing ability and adhesion to root dentin. The aim of this study is to coat GP with a bioactive material to enhance its sealing ability and adhesion to the root sealer and subsequently to the root dentin. The choice of coating method is limited by the nature of GP as it requires a technique that is not governed by high temperatures or uses organic solvents. In this study, biomimetic coating technique using 1.5 Tas-simulated body fluids (SBF was employed to coat the treated GP cones. The coated samples were characterized using Fourier transform infrared spectroscopy (FTIR, X-ray Diffraction (XRD, and field emission scanning electron microscope (FESEM. The presence of hydroxyl, carbonate, and phosphate groups was detected by FTIR while the formation of hydroxyapatite (HA/calcium phosphate was confirmed with XRD. FESEM revealed uniform, thin, and crystalline HA calcium phosphate coating. The adhesion of the coating to the GP substrate was assessed with microscratch technique. It was viable with cohesive failure mode. In conclusion, Tas-SBF is able to coat pretreated GP cones with a crystalline apatitic calcium phosphate layer.

  20. Dual Recognition Strategy for Specific and Sensitive Detection of Bacteria Using Aptamer-Coated Magnetic Beads and Antibiotic-Capped Gold Nanoclusters.

    Science.gov (United States)

    Cheng, Dan; Yu, Mengqun; Fu, Fei; Han, Weiye; Li, Gan; Xie, Jianping; Song, Yang; Swihart, Mark T; Song, Erqun

    2016-01-05

    Food poisoning and infectious diseases caused by pathogenic bacteria such as Staphylococcus aureus (SA) are serious public health concerns. A method of specific, sensitive, and rapid detection of such bacteria is essential and important. This study presents a strategy that combines aptamer and antibiotic-based dual recognition units with magnetic enrichment and fluorescent detection to achieve specific and sensitive quantification of SA in authentic specimens and in the presence of much higher concentrations of other bacteria. Aptamer-coated magnetic beads (Apt-MB) were employed for specific capture of SA. Vancomycin-stabilized fluorescent gold nanoclusters (AuNCs@Van) were prepared by a simple one-step process and used for sensitive quantification of SA in the range of 32-10(8) cfu/mL with the detection limit of 16 cfu/mL via a fluorescence intensity measurement. And using this strategy, about 70 cfu/mL of SA in complex samples (containing 3 × 10(8) cfu/mL of other different contaminated bacteria) could be successfully detected. In comparison to prior studies, the developed strategy here not only simplifies the preparation procedure of the fluorescent probes (AuNCs@Van) to a great extent but also could sensitively quantify SA in the presence of much higher concentrations of other bacteria directly with good accuracy. Moreover, the aptamer and antibiotic used in this strategy are much less expensive and widely available compared to common-used antibodies, making it cost-effective. This general aptamer- and antibiotic-based dual recognition strategy, combined with magnetic enrichment and fluorescent detection of trace bacteria, shows great potential application in monitoring bacterial food contamination and infectious diseases.

  1. The clinical significance of detection to heart rate deceleration capacity and heart rate variability in patients with chronic heart failure

    Directory of Open Access Journals (Sweden)

    Jiang-rong Zhou

    2015-01-01

    Full Text Available Objective: To study the change of heart rate deceleration capacity ( DC and heart rate variability in patients with chronic heart failure (CHF and its relationship with left ventricular ejection fraction (LVEF. Methods: DC, LVEF, time and frequency domain parameters of HRV were measured in 66 patients with CHF and 34 healthy adults (control group by using 24h Holter recordings and Echocardiography. The standard deviation of normal R-R intervals( SDNN, squares of differences between adjacent NN intervals ( RMSSD,low frequency power( LFn and high frequency power( HFn and the changes of LVEF were compared between  the two groups,the relationship between DC,LVEF and HRV were studied in patients with CHF. Results: The median value of DC in the patients with CHF was significantly lower than that in control group( 3.1 ± 2.4 ms vs 7.2 ± 1.3 ms,P <0.01.Incidence of abnormal DC in the CHF group was 57.5%,which was significantly higher than that in the control group (P <0.01.The HRV index, including SDNN、RMSSD、LFn、HFn, in the CHF group was significantly lower than that in normal control group (P < 0.01. Significant positive correlation between HRV index and LVEF were confirmed (P < 0.01. Conclusions: DC and HRV index are lower in patients with CHF and have a good correlation with the left ventricular ejection fraction.

  2. Personality disorders in heart failure patients requiring psychiatric management: comorbidity detections from a routine depression and anxiety screening protocol.

    Science.gov (United States)

    Tully, Phillip J; Selkow, Terina

    2014-12-30

    Several international guidelines recommend routine depression screening in cardiac disease populations. No previous study has determined the prevalence and comorbidities of personality disorders in patients presenting for psychiatric treatment after these screening initiatives. In the first stage 404 heart failure (HF) patients were routinely screened and 73 underwent structured interview when either of the following criteria were met: (a) Patient Health Questionnaire ≥10; (b) Generalized Anxiety Disorder Questionnaire ≥7); (c) Response to one item panic-screener. Or (d) Suicidality. Patients with personality disorders were compared to the positive-screen patients on psychiatric comorbidities. The most common personality disorders were avoidant (8.2%), borderline (6.8%) and obsessive compulsive (4.1%), other personality disorders were prevalent in less than patients. Personality disorder patients had significantly greater risk of major depression (risk ratio (RR) 1.2; 95% confidence interval (CI) 1.2-13.3), generalized anxiety disorder (RR 3.2; 95% CI 1.0-10.0), social phobia (RR 3.8; 95% CI 1.3-11.5) and alcohol abuse/dependence (RR 3.2; 95% 1.0-9.5). The findings that HF patients with personality disorders presented with complex psychiatric comorbidity suggest that pathways facilitating the integration of psychiatric services into cardiology settings are warranted when routine depression screening is in place. Crown Copyright © 2014. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Case study: IBM Watson Analytics cloud platform as Analytics-as-a-Service system for heart failure early detection

    OpenAIRE

    Guidi, Gabriele; Miniati, Roberto; Mazzola, Matteo; Iadanza, Ernesto

    2016-01-01

    In the recent years the progress in technology and the increasing availability of fast connections have produced a migration of functionalities in Information Technologies services, from static servers to distributed technologies. This article describes the main tools available on the market to perform Analytics as a Service (AaaS) using a cloud platform. It is also described a use case of IBM Watson Analytics, a cloud system for data analytics, applied to the following research scope: detect...

  4. Labeling transplanted mice islet with polyvinylpyrrolidone coated superparamagnetic iron oxide nanoparticles for in vivo detection by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Huang Hai; Xie Qiuping; Kang Muxing; Zhang Bo; Wu Yulian [Department of Surgery, 2nd Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009 (China); Zhang Hui; Chen Jin; Zhai Chuanxin; Yang Deren [State Key Lab of Silicon Materials and Department of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Jiang Biao, E-mail: wuyulian@medmail.com.c, E-mail: yulianwu2003@yahoo.c [Department of Radiology, 2nd Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009 (China)

    2009-09-09

    Superparamagnetic iron oxide nanoparticles (SPIO) are emerging as a novel probe for noninvasive cell tracking with magnetic resonance imaging (MRI) and have potential wide usage in medical research. In this study, we have developed a method using high-temperature hydrolysis of chelate metal alkoxide complexes to synthesize polyvinylpyrrolidone coated iron oxide nanoparticles (PVP-SPIO), as a biocompatible magnetic agent that can efficiently label mice islet {beta}-cells. The size, crystal structure and magnetic properties of the as-synthesized nanoparticles have been characterized. The newly synthesized PVP-SPIO with high stability, crystallinity and saturation magnetization can be efficiently internalized into {beta}-cells, without affecting viability and function. The imaging of 100 PVP-SPIO-labeled mice islets in the syngeneic renal subcapsular model of transplantation under a clinical 3.0 T MR imager showed high spatial resolution in vivo. These results indicated the great potential application of the PVP-SPIO as an MRI contrast agent for monitoring transplanted islet grafts in the clinical management of diabetes in the near future.

  5. Labeling transplanted mice islet with polyvinylpyrrolidone coated superparamagnetic iron oxide nanoparticles for in vivo detection by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Huang Hai; Xie Qiuping; Kang Muxing; Zhang Bo; Wu Yulian; Zhang Hui; Chen Jin; Zhai Chuanxin; Yang Deren; Jiang Biao

    2009-01-01

    Superparamagnetic iron oxide nanoparticles (SPIO) are emerging as a novel probe for noninvasive cell tracking with magnetic resonance imaging (MRI) and have potential wide usage in medical research. In this study, we have developed a method using high-temperature hydrolysis of chelate metal alkoxide complexes to synthesize polyvinylpyrrolidone coated iron oxide nanoparticles (PVP-SPIO), as a biocompatible magnetic agent that can efficiently label mice islet β-cells. The size, crystal structure and magnetic properties of the as-synthesized nanoparticles have been characterized. The newly synthesized PVP-SPIO with high stability, crystallinity and saturation magnetization can be efficiently internalized into β-cells, without affecting viability and function. The imaging of 100 PVP-SPIO-labeled mice islets in the syngeneic renal subcapsular model of transplantation under a clinical 3.0 T MR imager showed high spatial resolution in vivo. These results indicated the great potential application of the PVP-SPIO as an MRI contrast agent for monitoring transplanted islet grafts in the clinical management of diabetes in the near future.

  6. Failure to detect circulating DNA-anti-DNA complexes by four radioimmunological methods in patients with systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Izui, S.; Lambert, P.H.; Miescher, P.A.

    1977-01-01

    The presence of DNA-anti-DNA complexes in sera from patients with systemic lupus erythematosus (SLE) was investigated by two new radioimmunoassays (RIA) developed for this purpose and by measuring the CLq and DNA binding activity of serum before and after treatment with DNAse. Two direct RIA developed in this study were based on the reactivity of [ 3 H]actinomycin D ([ 3 H]ACT-D) or solid-phase methylated bovine serum albumin (mBSA) with DNA-anti-DNA complexes. DNA-anti-DNA complexes prepared in vitro could be efficiently detected at various antigen-antibody ratios by these two RIA. Increased levels of circulating immune complexes as indicated by the CLq binding test were found in 52% of SLE sera. However, the frequency of specific DNA-anti-DNA complexes detected in SLE sera was very low. Only 6% of sera exhibited an increased value deviating by more than three s.d. from the normal mean when tested with the [ 3 H]ACT-D binding RIA or the solid-phase mBSA RIA. On the other hand, there was no significant difference in the serum CLq or DNA binding activity after treatment with DNAse. These results suggest that DNA-anti-DNA complexes do not occur frequently in circulating blood and represent only a very small portion of the immune complexes detected in serum from patients with SLE. (author)

  7. Failure to detect circulating DNA-anti-DNA complexes by four radioimmunological methods in patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Izui, S; Lambert, P H; Miescher, P A [Hopital Cantonal Geneve (Switzerland)

    1977-12-01

    The presence of The DNA-anti-DNA complexes in sera from patients with systemic lupus erythematosus (SLE) was investigated by two new radioimmunoassays (RIA) developed for this purpose and by measuring the CLq and DNA binding activity of serum before and after treatment with DNAse. Two direct RIA developed in this study were based on the reactivity of (/sup 3/H)actinomycin D ((/sup 3/H)ACT-D) or solid-phase methylated bovine serum albumin (mBSA) with DNA-anti-DNA complexes. DNA-anti-DNA complexes prepared in vitro could be efficiently detected at various antigen-antibody ratios by these two RIA. Increased levels of circulating immune complexes as indicated by the CLq binding test were found in 52% of the SLE sera. However, the frequency of specific DNA-anti-DNA complexes detected in the SLE sera was very low. Only 6% of the sera exhibited an increased value deviating by more than three s.d. from the normal mean when tested with the (/sup 3/H)ACT-D binding RIA or the solid-phase mBSA RIA. On the other hand, there was no significant difference in the serum CLq or DNA binding activity after treatment with DNAse. These results suggest that DNA-anti-DNA complexes do not occur frequently in circulating blood and represent only a very small portion of the immune complexes detected in serum from patients with SLE.

  8. Machine Learning Methods Improve Prognostication, Identify Clinically Distinct Phenotypes, and Detect Heterogeneity in Response to Therapy in a Large Cohort of Heart Failure Patients.

    Science.gov (United States)

    Ahmad, Tariq; Lund, Lars H; Rao, Pooja; Ghosh, Rohit; Warier, Prashant; Vaccaro, Benjamin; Dahlström, Ulf; O'Connor, Christopher M; Felker, G Michael; Desai, Nihar R

    2018-04-12

    Whereas heart failure (HF) is a complex clinical syndrome, conventional approaches to its management have treated it as a singular disease, leading to inadequate patient care and inefficient clinical trials. We hypothesized that applying advanced analytics to a large cohort of HF patients would improve prognostication of outcomes, identify distinct patient phenotypes, and detect heterogeneity in treatment response. The Swedish Heart Failure Registry is a nationwide registry collecting detailed demographic, clinical, laboratory, and medication data and linked to databases with outcome information. We applied random forest modeling to identify predictors of 1-year survival. Cluster analysis was performed and validated using serial bootstrapping. Association between clusters and survival was assessed with Cox proportional hazards modeling and interaction testing was performed to assess for heterogeneity in response to HF pharmacotherapy across propensity-matched clusters. Our study included 44 886 HF patients enrolled in the Swedish Heart Failure Registry between 2000 and 2012. Random forest modeling demonstrated excellent calibration and discrimination for survival (C-statistic=0.83) whereas left ventricular ejection fraction did not (C-statistic=0.52): there were no meaningful differences per strata of left ventricular ejection fraction (1-year survival: 80%, 81%, 83%, and 84%). Cluster analysis using the 8 highest predictive variables identified 4 clinically relevant subgroups of HF with marked differences in 1-year survival. There were significant interactions between propensity-matched clusters (across age, sex, and left ventricular ejection fraction and the following medications: diuretics, angiotensin-converting enzyme inhibitors, β-blockers, and nitrates, P <0.001, all). Machine learning algorithms accurately predicted outcomes in a large data set of HF patients. Cluster analysis identified 4 distinct phenotypes that differed significantly in outcomes and in

  9. Expression profile of Rab5, Rab7, tryptophan aspartate-containing coat protein, leprae lipoarabinomannan, and phenolic glycolipid-1 on the failure of the phagolysosome process in macrophages of leprosy patients as a viability marker of Mycobacterium leprae.

    Science.gov (United States)

    Prakoeswa, Cita Rosita Sigit; Wahyuni, Ratna; Iswahyudi; Adriaty, Dinar; Yusuf, Irawan; Sutjipto; Agusni, Indropo; Izumi, Shinzo

    2016-06-01

    Phagolysosome process in macrophage of leprosy patients' is important in the early phase of eliminating Mycobacterium leprae invasion. This study was to clarify the involvement of Rab5, Rab7, and trytophan aspartate-containing coat protein (TACO) from host macrophage and leprae lipoarabinomannan (Lep-LAM) and phenolic glycolipid-1 (PGL-1) from M. leprae cell wall as the reflection of phagolysosome process in relation to 16 subunit ribosomal RNA (16S rRNA) M. leprae as a marker of viability of M. leprae. Using a cross sectional design study, skin biopsies were obtained from 47 newly diagnosed, untreated leprosy at Dr Soetomo Hospital, Surabaya, Indonesia. RNA isolation and complementary DNA synthesis were performed. Samples were divided into two groups: 16S rRNA M. leprae-positive and 16S rRNA M. leprae-negative. The expressions of Rab5, Rab7, TACO, Lep-LAM, and PGL-1 were assessed with an immunohistochemistry technique. Using Mann-Whitney U analysis, a significant difference in the expression profile of Rab5, Rab7, Lep-LAM, and PGL-1 was found (p.05). Spearman analysis revealed that there was a significant correlation between the score of Rab5, Rab7, Lep-LAM, and PGL-1 and the score of 16S rRNA M. leprae (pleprae infection, Rab5, Rab7, and Lep-LAM play important roles in the failure of phagolysosome process via a membrane trafficking pathway, while PGL-1 plays a role via blocking lysosomal activities. These inventions might be used for the development of an early diagnostic device in the future. Copyright © 2016 Asian-African Society for Mycobacteriology. Published by Elsevier Ltd. All rights reserved.

  10. Detection and prognostic impact of renal dysfunction in patients with chronic heart failure and normal serum creatinine.

    Science.gov (United States)

    Scrutinio, Domenico; Passantino, Andrea; Lagioia, Rocco; Santoro, Daniela; Cacciapaglia, Erasmo

    2011-03-03

    Accurate identification of renal dysfunction (RD) is crucial to risk stratification in chronic heart failure (CHF). Patients with CHF are at special risk of having RD despite normal serum creatinine (SCr), owing to a decreased Cr generation. At low levels of SCr, the equations estimating renal function are less accurate. This study was aimed to assess and compare the prognostic value of formulas estimating renal function in CHF patients with normal SCr. We studied 462 patients with systolic CHF and normal SCr. Creatinine clearance was estimated by the Cockcroft-Gault (eCrCl) and glomerular filtration rate by the 4-variable MDRD equation (eGFR); eCrCl normalized for body-surface area (eCrCl(BSA)) was calculated. The primary outcome was all-cause mortality at 2 years. Seventy five patients died. At multivariate Cox regression analysis, only eCrCl(BSA) was significantly associated with mortality (p = 0.006); eGFR (p = 0.24), eCrCl (p = 0.09) and BUN (p = 0.14) were not statistically significant predictors. The patients in the lowest eCrCl(BSA) quartile had an adjusted 2.1-fold (CI: 1.06-4.1) increased risk of mortality, compared with those in the referent quartile. Two-year survival was 70.4% in the lowest eCrCl(BSA) quartile and 89.7% in the referent quartile. Other independent predictors of mortality were ischemic etiology (RR: 2.16 [CI: 1.3-3.5], p = 0.0017), NYHA III/IV class (RR: 2.45 [CI: 1.51-3.97], p = 0.0003), LVEF high-risk subgroup and can more accurately be identified by the CG formula corrected for BSA than the MDRD. Copyright © 2009 Elsevier B.V. All rights reserved.

  11. Correlación vibroacústica: detección cognitiva e identificación de fallas. // Vibroacoustic correlation: Failure identification and cognoscitive detection

    Directory of Open Access Journals (Sweden)

    F. Miyara

    2000-03-01

    Full Text Available Se presenta una metodología para la investigación diagnóstica de fallas en máquinas industriales mediante un correladorvibroacústico, dispositivo que permite comparar automáticamente las frecuencias de una señal acústica y una vibratoria. Seconjuga así la habilidad humana para la detección de ruidos anómalos con la identificación objetiva de su procedencia.Palabras claves Acústica, ruido, vibraciones, correlación, fallas, identificación_____________________________________________________________________________AbstractA methodology for the diagnosis investigation of failure in industrial machines by means of a vibroacustic corelator ispresented, device that allow to compare the frecuencies of an acoustic signal and a vibratory one automatically.In this waythe human ability for the detection of anomalous noises is conjugated with the objective identification of their origin.Key words: Acoustic, Noise, Vibrations, Correlation, Failure Identification.

  12. Prevalence and evolution of low frequency HIV drug resistance mutations detected by ultra deep sequencing in patients experiencing first line antiretroviral therapy failure.

    Science.gov (United States)

    Vandenhende, Marie-Anne; Bellecave, Pantxika; Recordon-Pinson, Patricia; Reigadas, Sandrine; Bidet, Yannick; Bruyand, Mathias; Bonnet, Fabrice; Lazaro, Estibaliz; Neau, Didier; Fleury, Hervé; Dabis, François; Morlat, Philippe; Masquelier, Bernard

    2014-01-01

    Clinical relevance of low-frequency HIV-1 variants carrying drug resistance associated mutations (DRMs) is still unclear. We aimed to study the prevalence of low-frequency DRMs, detected by Ultra-Deep Sequencing (UDS) before antiretroviral therapy (ART) and at virological failure (VF), in HIV-1 infected patients experiencing VF on first-line ART. Twenty-nine ART-naive patients followed up in the ANRS-CO3 Aquitaine Cohort, having initiated ART between 2000 and 2009 and experiencing VF (2 plasma viral loads (VL) >500 copies/ml or one VL >1000 copies/ml) were included. Reverse transcriptase and protease DRMs were identified using Sanger sequencing (SS) and UDS at baseline (before ART initiation) and VF. Additional low-frequency variants with PI-, NNRTI- and NRTI-DRMs were found by UDS at baseline and VF, significantly increasing the number of detected DRMs by 1.35 fold (plow-frequency DRMs modified ARV susceptibility predictions to the prescribed treatment for 1 patient at baseline, in whom low-frequency DRM was found at high frequency at VF, and 6 patients at VF. DRMs found at VF were rarely detected as low-frequency DRMs prior to treatment. The rare low-frequency NNRTI- and NRTI-DRMs detected at baseline that correlated with the prescribed treatment were most often found at high-frequency at VF. Low frequency DRMs detected before ART initiation and at VF in patients experiencing VF on first-line ART can increase the overall burden of resistance to PI, NRTI and NNRTI.

  13. Applications of a morphological scene change detection (MSCD) for visual leak and failure identification in process and chemical engineering

    Science.gov (United States)

    Tickle, Andrew J.; Harvey, Paul K.; Smith, Jeremy S.

    2010-10-01

    Morphological Scene Change Detection (MSCD) is a process typically tasked at detecting relevant changes in a guarded environment for security applications. This can be implemented on a Field Programmable Gate Array (FPGA) by a combination of binary differences based around exclusive-OR (XOR) gates, mathematical morphology and a crucial threshold setting. The additional ability to set up the system in virtually any location due to the FPGA makes it ideal for insertion into an autonomous mobile robot for patrol duties. However, security is not the only potential of this robust algorithm. This paper details how such a system can be used for the detection of leaks in piping for use in the process and chemical industries and could be deployed as stated in the above manner. The test substance in this work was water, which was pumped either as a liquid or as low pressure steam through a simple pipe configuration with holes at set points to simulate the leaks. These holes were situated randomly at either the center of a pipe (in order to simulate an impact to it) or at a joint or corner (to simulate a failed weld). Imagery of the resultant leaks, which were visualised as drips or the accumulation of steam, which where analysed using MATLAB to determine their pixel volume in order to calibrate the trigger for the MSCD. The triggering mechanism is adaptive to make it possible in theory for the type of leak to be determined by the number of pixels in the threshold of the image and a numerical output signal to state which of the leak situations is being observed. The system was designed using the DSP Builder package from Altera so that its graphical nature is easily comprehensible to the non-embedded system designer. Furthermore, all the data from the DSP Builder simulation underwent verification against MATLAB comparisons using the image processing toolbox in order to validate the results.

  14. High Hydrogen Content Graphene Hydride Compounds & High Cross-­ Section Cladding Coatings for Fast Neutron Detection

    Energy Technology Data Exchange (ETDEWEB)

    Chandrashekhar, MVS [Univ. of South Carolina, Columbia, SC (United States)

    2017-06-21

    The objective is to develop and implement a superior low-cost, large area (potentially >32in), easily deployable, close proximity, harsh environment innovative neutron sensor needed for next generation fuel cycle monitoring. We will exploit recent breakthroughs at the PI’s lab on the electrochemistry of epitaxial graphene (EG) formed on commercial SiC wafers, a transformative nanomaterial system with superior radiation detection and durability properties to develop a new paradigm in detection for fast neutrons, a by-product of fission reactors. There are currently few effective detection/monitoring schemes, especially solid-state ones at present. This is essential for monitoring and control of future fuel cycles to make them more efficient and reliable. By exploiting these novel materials, as well as innovative hybrid SiC/EG/Cladding device architectures conceived by the team, will develop low-cost, high performance solutions to fast-neutron detection. Finally, we will also explore 3-terminal device implementations for neutron detectors with built-in electronic gain to further shrink these devices and improve their sensitivity.

  15. Combined use of vancomycin-modified Ag-coated magnetic nanoparticles and secondary enhanced nanoparticles for rapid surface-enhanced Raman scattering detection of bacteria.

    Science.gov (United States)

    Wang, Chongwen; Gu, Bing; Liu, Qiqi; Pang, Yuanfeng; Xiao, Rui; Wang, Shengqi

    2018-01-01

    Pathogenic bacteria have always been a significant threat to human health. The detection of pathogens needs to be rapid, accurate, and convenient. We present a sensitive surface-enhanced Raman scattering (SERS) biosensor based on the combination of vancomycin-modified Ag-coated magnetic nanoparticles (Fe 3 O 4 @Ag-Van MNPs) and Au@Ag nanoparticles (NPs) that can effectively capture and discriminate bacterial pathogens from solution. The high-performance Fe 3 O 4 @Ag MNPs were modified with vancomycin and used as bacteria capturer for magnetic separation and enrichment. The modified MNPS were found to exhibit strong affinity with a broad range of Gram-positive and Gram-negative bacteria. After separating and rinsing bacteria, Fe 3 O 4 @Ag-Van MNPs and Au@Ag NPs were synergistically used to construct a very large number of hot spots on bacteria cells, leading to ultrasensitive SERS detection. The dominant merits of our dual enhanced strategy included high bacterial-capture efficiency (>65%) within a wide pH range (pH 3.0-11.0), a short assay time (<30 min), and a low detection limit (5×10 2 cells/mL). Moreover, the spiked tests show that this method is still valid in milk and blood samples. Owing to these capabilities, the combined system enabled the sensitive and specific discrimination of different pathogens in complex solution, as verified by its detection of Gram-positive bacterium Escherichia coli , Gram-positive bacterium Staphylococcus aureus , and methicillin-resistant S. aureus . This method has great potential for field applications in food safety, environmental monitoring, and infectious disease diagnosis.

  16. Extraction of total nucleic acid based on silica-coated magnetic particles for RT-qPCR detection of plant RNA virus/viroid.

    Science.gov (United States)

    Sun, Ning; Deng, Congliang; Zhao, Xiaoli; Zhou, Qi; Ge, Guanglu; Liu, Yi; Yan, Wenlong; Xia, Qiang

    2014-02-01

    In this study, a nucleic acid extraction method based on silica-coated magnetic particles (SMPs) and RT-qPCR assay was developed to detect Arabis mosaic virus (ArMV), Lily symptomless virus (LSV), Hop stunt viroid (HSVd) and grape yellow speckle viroid 1 (GYSVd-1). The amplification sequences of RT-qPCR were reversely transcribed in vitro as RNA standard templates. The standard curves covered six or seven orders of magnitude with a detection limit of 100 copies per each assay. Extraction efficiency of the SMPs method was evaluated by recovering spiked ssRNAs from plant samples and compared to two commercial kits (TRIzol and RNeasy Plant mini kit). Results showed that the recovery rate of SMPs method was comparable to the commercial kits when spiked ssRNAs were extracted from lily leaves, whereas it was two or three times higher than commercial kits when spiked ssRNAs were extracted from grapevine leaves. SMPs method was also used to extract viral nucleic acid from15 ArMV-positive lily leaf samples and 15 LSV-positive lily leaf samples. SMPs method did not show statistically significant difference from other methods on detecting ArMV, but LSV. The SMPs method has the same level of virus load as the TRIzol, and its mean virus load of was 0.5log10 lower than the RNeasy Plant mini kit. Nucleic acid was extracted from 19 grapevine-leaf samples with SMPs and the two commercial kits and subsequently screened for HSVd and GYSVd-1 by RT-qPCR. Regardless of HSVd or GYSVd-1, SMPs method outperforms other methods on both positive rate and the viroid load. In conclusion, SMPs method was able to efficiently extract the nucleic acid of RNA viruses or viroids, especially grapevine viroids, from lily-leaf or grapevine-leaf samples for RT-qPCR detection. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Flexible and Compressible PEDOT:PSS@Melamine Conductive Sponge Prepared via One-Step Dip Coating as Piezoresistive Pressure Sensor for Human Motion Detection.

    Science.gov (United States)

    Ding, Yichun; Yang, Jack; Tolle, Charles R; Zhu, Zhengtao

    2018-05-09

    Flexible and wearable pressure sensor may offer convenient, timely, and portable solutions to human motion detection, yet it is a challenge to develop cost-effective materials for pressure sensor with high compressibility and sensitivity. Herein, a cost-efficient and scalable approach is reported to prepare a highly flexible and compressible conductive sponge for piezoresistive pressure sensor. The conductive sponge, poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS)@melamine sponge (MS), is prepared by one-step dip coating the commercial melamine sponge (MS) in an aqueous dispersion of poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). Due to the interconnected porous structure of MS, the conductive PEDOT:PSS@MS has a high compressibility and a stable piezoresistive response at the compressive strain up to 80%, as well as good reproducibility over 1000 cycles. Thereafter, versatile pressure sensors fabricated using the conductive PEDOT:PSS@MS sponges are attached to the different parts of human body; the capabilities of these devices to detect a variety of human motions including speaking, finger bending, elbow bending, and walking are evaluated. Furthermore, prototype tactile sensory array based on these pressure sensors is demonstrated.

  18. Determination of arsenic in ambient water at sub-part-per-trillion levels by hydride generation Pd coated platform collection and GFAAS detection.

    Science.gov (United States)

    Liang, L; Lazoff, S; Chan, C; Horvat, M; Woods, J S

    1998-11-01

    A method for trace determination of total arsenic in ambient waters is described. Arsenic is separated on-line from a large volume water sample by hydride generation and purging, pre-collected on a Pd coated pyrolytic platform cuvette using a simple and inexpensive system, and finally detected by GFAAS. Instrument parameters, hydride generation, transportation, and collection were optimized. The analytical behavior for major species including As(3+), As(5+), monomethyl As (MMA), and dimethyl As (DMA) were investigated individually. Problems arising from use of the system were discussed and eliminated. The necessity of sample digestion and an efficient digestion method were studied. Sample digestion for water with low organic content such as tap water and clean ground water and some clean surface water can be omitted. The method detection limit (MDL) is 0.3 ng l(-1) for a 25 ml water sample. Recoveries close to 100% with R.S.D.rain, sewage effluent, and saline water from different origins in the US, China, and Canada were collected and analyzed using ultra clean sampling and analysis techniques. The background levels of As in most water analyzed were established for the first time, and found to be far above the EPA's health effect criteria, 18 ng l(-1).

  19. Barley husk carbon as the fiber coating for the solid-phase microextraction of twelve pesticides in vegetables prior to gas chromatography-mass spectrometric detection.

    Science.gov (United States)

    Liang, Weiqian; Wang, Juntao; Zang, Xiaohuan; Dong, Wenhuan; Wang, Chun; Wang, Zhi

    2017-03-31

    In this work, a barley husk biomaterial was successfully carbonized by hydrothermal method. The carbon had a high specific surface area and good stability. It was coated onto a stainless steel wire through sol-gel technique to prepare a solid-phase microextraction fiber for the extraction of trace levels of twelve pesticides (tsumacide, fenobucarb, indoxacarb, diethofencarb, thimet, terbufos, malathion, thiamethoxam, imidacloprid, buprofezin, acetamiprid, thiamethoxam) from vegetable samples prior to gas chromatography-mass spectrometric (GC-MS) detection. The main experimental parameters that could influence the extraction efficiency such as extraction time, extraction temperature, sample pH, sample salinity, stirring rate, desorption temperature and desorption time, were investigated. Under the optimized conditions, the linearity was observed in the range of 0.2-75.0μgkg -1 for tomato samples, and 0.3-60.0μgkg -1 for cucumber samples, with the correlation coefficients (r) ranging from 0.9959 to 0.9983. The limits of detection of the method were 0.01-0.05μgkg -1 for tomato samples, and 0.03-0.10μgkg -1 for cucumber samples. The recoveries of the analytes for the method from spiked samples were in the range of 76%-104%, and the precision, expressed as the relative standard deviations, was less than 12%. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Respiratory Failure

    Science.gov (United States)

    Respiratory failure happens when not enough oxygen passes from your lungs into your blood. Your body's organs, ... brain, need oxygen-rich blood to work well. Respiratory failure also can happen if your lungs can' ...

  1. Understanding Coatings that Protect Plasmonic Structures for Materials Characterization and Detection and Identification of Chemical, Biological and Explosive Agents

    Science.gov (United States)

    2013-04-11

    require the rough metal films that result from dewetting , the silver films for X-ray photoelectron spectroscopy (XPS) and XR study were made thick...enough to avoid dewetting , since smooth, planar films were needed for those techniques. The preparation conditions for these flat samples were the same...spectroscopy (XPS) and AFM. While TERS and SERS- based detection techniques require the rough metal films that result from dewetting , the silver 4 films

  2. Rapid, highly sensitive detection of herpes simplex virus-1 using multiple antigenic peptide-coated superparamagnetic beads.

    Science.gov (United States)

    Ran, Ying-Fen; Fields, Conor; Muzard, Julien; Liauchuk, Viktoryia; Carr, Michael; Hall, William; Lee, Gil U

    2014-12-07

    A sensitive, rapid, and label free magnetic bead aggregation (MBA) assay has been developed that employs superparamagnetic (SPM) beads to capture, purify, and detect model proteins and the herpes simplex virus (HSV). The MBA assay is based on monitoring the aggregation state of a population of SPM beads using light scattering of individual aggregates. A biotin-streptavidin MBA assay had a femtomolar (fM) level sensitivity for analysis times less than 10 minutes, but the response of the assay becomes nonlinear at high analyte concentrations. A MBA assay for the detection of HSV-1 based on a novel peptide probe resulted in the selective detection of the virus at concentrations as low as 200 viral particles (vp) per mL in less than 30 min. We define the parameters that determine the sensitivity and response of the MBA assay, and the mechanism of enhanced sensitivity of the assay for HSV. The speed, relatively low cost, and ease of application of the MBA assay promise to make it useful for the identification of viral load in resource-limited and point-of-care settings where molecular diagnostics cannot be easily implemented.

  3. Detection and characterisation of trypanosome strains supposedly resistant to trypanocidal drugs in Senegal; Detection au buffy coat technique et en ELISA de souches de trypanosomes supposees chimioresistantes au Senegal et caracterisation therapeutique

    Energy Technology Data Exchange (ETDEWEB)

    Diaite, A; Seye, M; Mane, A; Ndiaye, T; Seye, M M [Institut Senegalais de Recherches Agricoles (ISRA), Dakar (Senegal). Lab. de Parasitologie

    1997-02-01

    In the region of Sokone cattle are constantly exposed to infections with trypanosomes transmitted by Glossina morsitans submorsitans and G. palpalis gambiensis. Trypanocidal drugs are widely used by the farmers on the 50,000 cattle present in the region. Consequently, drug resistance has become a major problem. During the present study goats were inoculated with trypanosome strains isolated from infected cattle. Following the appearance of parasitaemia, the animals were treated with either Berenil, Samorin or Ethidium. The results indicated the parasites were susceptible to Samorin, but one of the Trypanosoma vivax strains showed resistance to Berenil and Ethidium. In addition, the performance of the antigen detection ELISA was compared with that of the Buffy Coat Technique using more than 1000 serum samples from the Sokone region and 100 samples from Northern Senegal infested with tsetse flies. The results showed a very high specificity of 98%. However, additional tests will be necessary to assess the sensitivity properly. (author). 3 refs, 7 tabs.

  4. Constructed ILs coated porous magnetic nickel cobaltate hexagonal nanoplates sensing materials for the simultaneous detection of cumulative toxic metals

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Yuanyuan; Zhang, Lei, E-mail: zhanglei63@126.com

    2017-07-05

    Highlights: • A novel sensor material based on ionic liquids@nickel cobaltate was constructed. • Various morphologies of NiCo{sub 2}O{sub 4} were synthesized for electrocatalytic comparison. • ILs@NiCo{sub 2}O{sub 4}-P was used to detect cumulative toxic metals for the first time. • The sensor displayed well reproducibility, excellent selectivity and sensitivity. • The method was applied to detect practical samples with satisfactory results. - Abstract: The different morphologies of magnetic nickel cobaltate (NiCo{sub 2}O{sub 4}) electrocatalysts, consisting of nanoparticles (NiCo{sub 2}O{sub 4}-N), nanoplates (NiCo{sub 2}O{sub 4}-P) and microspheres (NiCo{sub 2}O{sub 4}-S) were fabricated. It was found that the electrocatalytic properties of the sensing materials were strongly dependent on morphology and specific surface area. The porous NiCo{sub 2}O{sub 4} hexagonal nanoplates coupled with ILs as modified materials (ILs@NiCo{sub 2}O{sub 4}-P) for the simultaneous determination of thallium (Tl{sup +}), lead (Pb{sup 2+}) and copper (Cu{sup 2+}), exhibited high sensitivity, long-time stability and good repeatability. The enhanced electrocatalytic activity was attributed to relatively large specific surface area, excellent electronic conductivity, and unique porous nanostructure. The analytical performance of the constructed electrode on detection of Tl{sup +}, Pb{sup 2+} and Cu{sup 2+} was examined using differential pulse anodic stripping voltammetry (DPASV). Under optimal conditions, the electrode showed a good linear response to Tl{sup +}, Pb{sup 2+}and Cu{sup 2+} in the concentration range of 0.1–100.0, 0.1–100.0 and 0.05–100.0 μg/L, respectively. The detection limits (S/N = 3) were 0.046, 0.034 and 0.029 μg/L for Tl{sup +}, Pb{sup 2+} and Cu{sup 2+}, respectively. The fabricated sensor was successfully applied to detect trace Tl{sup +}, Pb{sup 2+} and Cu{sup 2+} in various water and soil samples with satisfactory results. Hence, this work

  5. Heart Failure

    Science.gov (United States)

    Heart failure is a condition in which the heart can't pump enough blood to meet the body's needs. Heart failure does not mean that your heart has stopped ... and shortness of breath Common causes of heart failure are coronary artery disease, high blood pressure and ...

  6. Clinical development of a failure detection-based online repositioning strategy for prostate IMRT--Experiments, simulation, and dosimetry study

    International Nuclear Information System (INIS)

    Liu Wu; Qian Jianguo; Hancock, Steven L.; Xing, Lei; Luxton, Gary

    2010-01-01

    Purpose: To implement and evaluate clinic-ready adaptive imaging protocols for online patient repositioning (motion tracking) during prostate IMRT using treatment beam imaging supplemented by minimal, as-needed use of on-board kV. Methods: The authors examine the two-step decision-making strategy: (1) Use cine-MV imaging and online-updated characterization of prostate motion to detect target motion that is potentially beyond a predefined threshold and (2) use paired MV-kV 3D localization to determine overthreshold displacement and, if needed, reposition the patient. Two levels of clinical implementation were evaluated: (1) Field-by-field based motion correction for present-day linacs and (2) instantaneous repositioning for new-generation linacs with capabilities of simultaneous MV-kV imaging and remote automatic couch control during treatment delivery. Experiments were performed on a Varian Trilogy linac in clinical mode using a 4D motion phantom programed with prostate motion trajectories taken from patient data. Dosimetric impact was examined using a 2D ion chamber array. Simulations were done for 536 trajectories from 17 patients. Results: Despite the loss of marker detection efficiency caused by the MLC leaves sometimes obscuring the field at the marker's projected position on the MV imager, the field-by-field correction halved (from 23% to 10%) the mean percentage of time that target displacement exceeded a 3 mm threshold, as compared to no intervention. This was achieved at minimal cost in additional imaging (average of one MV-kV pair per two to three treatment fractions) and with a very small number of repositionings (once every four to five fractions). Also with low kV usage (∼2/fraction), the instantaneous repositioning approach reduced overthreshold time by more than 75% (23% to 5%) even with severe MLC blockage as often encountered in current IMRT and could reduce the overthreshold time tenfold (to <2%) if the MLC blockage problem were relieved. The

  7. Clinical development of a failure detection-based online repositioning strategy for prostate IMRT--experiments, simulation, and dosimetry study.

    Science.gov (United States)

    Liu, Wu; Qian, Jianguo; Hancock, Steven L; Xing, Lei; Luxton, Gary

    2010-10-01

    To implement and evaluate clinic-ready adaptive imaging protocols for online patient repositioning (motion tracking) during prostate IMRT using treatment beam imaging supplemented by minimal, as-needed use of on-board kV. The authors examine the two-step decision-making strategy: (1) Use cine-MV imaging and online-updated characterization of prostate motion to detect target motion that is potentially beyond a predefined threshold and (2) use paired MV-kV 3D localization to determine overthreshold displacement and, if needed, reposition the patient. Two levels of clinical implementation were evaluated: (1) Field-by-field based motion correction for present-day linacs and (2) instantaneous repositioning for new-generation linacs with capabilities of simultaneous MV-kV imaging and remote automatic couch control during treatment delivery. Experiments were performed on a Varian Trilogy linac in clinical mode using a 4D motion phantom programed with prostate motion trajectories taken from patient data. Dosimetric impact was examined using a 2D ion chamber array. Simulations were done for 536 trajectories from 17 patients. Despite the loss of marker detection efficiency caused by the MLC leaves sometimes obscuring the field at the marker's projected position on the MV imager, the field-by-field correction halved (from 23% to 10%) the mean percentage of time that target displacement exceeded a 3 mm threshold, as compared to no intervention. This was achieved at minimal cost in additional imaging (average of one MV-kV pair per two to three treatment fractions) and with a very small number of repositionings (once every four to five fractions). Also with low kV usage (approximation 2/fraction), the instantaneous repositioning approach reduced overthreshold time by more than 75% (23% to 5%) even with severe MLC blockage as often encountered in current IMRT and could reduce the overthreshold time tenfold (to < 2%) if the MLC blockage problem were relieved. The information

  8. Clinical development of a failure detection-based online repositioning strategy for prostate IMRT--Experiments, simulation, and dosimetry study

    Energy Technology Data Exchange (ETDEWEB)

    Liu Wu; Qian Jianguo; Hancock, Steven L.; Xing, Lei; Luxton, Gary [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305-5847 (United States) and Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut 06510 (United States); Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305-5847 (United States)

    2010-10-15

    Purpose: To implement and evaluate clinic-ready adaptive imaging protocols for online patient repositioning (motion tracking) during prostate IMRT using treatment beam imaging supplemented by minimal, as-needed use of on-board kV. Methods: The authors examine the two-step decision-making strategy: (1) Use cine-MV imaging and online-updated characterization of prostate motion to detect target motion that is potentially beyond a predefined threshold and (2) use paired MV-kV 3D localization to determine overthreshold displacement and, if needed, reposition the patient. Two levels of clinical implementation were evaluated: (1) Field-by-field based motion correction for present-day linacs and (2) instantaneous repositioning for new-generation linacs with capabilities of simultaneous MV-kV imaging and remote automatic couch control during treatment delivery. Experiments were performed on a Varian Trilogy linac in clinical mode using a 4D motion phantom programed with prostate motion trajectories taken from patient data. Dosimetric impact was examined using a 2D ion chamber array. Simulations were done for 536 trajectories from 17 patients. Results: Despite the loss of marker detection efficiency caused by the MLC leaves sometimes obscuring the field at the marker's projected position on the MV imager, the field-by-field correction halved (from 23% to 10%) the mean percentage of time that target displacement exceeded a 3 mm threshold, as compared to no intervention. This was achieved at minimal cost in additional imaging (average of one MV-kV pair per two to three treatment fractions) and with a very small number of repositionings (once every four to five fractions). Also with low kV usage ({approx}2/fraction), the instantaneous repositioning approach reduced overthreshold time by more than 75% (23% to 5%) even with severe MLC blockage as often encountered in current IMRT and could reduce the overthreshold time tenfold (to <2%) if the MLC blockage problem were

  9. Gear Tooth Failure Detection by the Resonance Demodulation Technique and the Instantaneous Power Spectrum Method – A Comparative Study

    Directory of Open Access Journals (Sweden)

    Ahmad Ghasemloonia

    2011-01-01

    Full Text Available The role of gears in industry for speed and torque variation purposes is obvious. The gearbox diagnostic methods have been improved quickly in recent years. In this paper, two of the newest methods, the resonance demodulation technique (R.D, and the instantaneous power spectrum technique (IPS are applied to gearbox vibration signals and their capabilities in fault detection are compared. Yet, the important role of time averaging should not be dispensed with, as it is the primary step for both techniques. In the present study, the mathematical method of these techniques, according to the mathematical vibration model of gears, is introduced, these techniques are applied to the test rig data, and finally the results of both methods are compared. The results indicate that in each method, the location of fault can be estimated and it is located in the same angular position in both methods. The IPS method is applicable to severe faults, whereas the resonance demodulation technique is a simple tool to recognize the fault at each severity and at the early stages of fault generation.

  10. Thermal barrier coatings: Coating methods, performance, and heat engine applications. (Latest citations from the EI Compendex*plus database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-02-01

    The bibliography contains citations concerning conference proceedings on coating methods, performance evaluations, and applications of thermal barrier coatings as protective coatings for heat engine components against high temperature corrosions and chemical erosions. The developments of thermal barrier coating techniques for high performance and reliable gas turbines, diesel engines, jet engines, and internal combustion engines are presented. Topics include plasma sprayed coating methods, yttria stabilized zirconia coatings, coating life models, coating failure and durability, thermal shock and cycling, and acoustic emission analysis of coatings. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  11. Thermal barrier coatings: Coating methods, performance, and heat engine applications. (Latest citations from the EI Compendex*plus database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    The bibliography contains citations concerning conference proceedings on coating methods, performance evaluations, and applications of thermal barrier coatings as protective coatings for heat engine components against high temperature corrosions and chemical erosions. The developments of thermal barrier coating techniques for high performance and reliable gas turbines, diesel engines, jet engines, and internal combustion engines are presented. Topics include plasma sprayed coating methods, yttria stabilized zirconia coatings, coating life models, coating failure and durability, thermal shock and cycling, and acoustic emission analysis of coatings. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  12. Fialuridine induces acute liver failure in chimeric TK-NOG mice: a model for detecting hepatic drug toxicity prior to human testing.

    Directory of Open Access Journals (Sweden)

    Dan Xu

    2014-04-01

    Full Text Available Seven of 15 clinical trial participants treated with a nucleoside analogue (fialuridine [FIAU] developed acute liver failure. Five treated participants died, and two required a liver transplant. Preclinical toxicology studies in mice, rats, dogs, and primates did not provide any indication that FIAU would be hepatotoxic in humans. Therefore, we investigated whether FIAU-induced liver toxicity could be detected in chimeric TK-NOG mice with humanized livers.Control and chimeric TK-NOG mice with humanized livers were treated orally with FIAU 400, 100, 25, or 2.5 mg/kg/d. The response to drug treatment was evaluated by measuring plasma lactate and liver enzymes, by assessing liver histology, and by electron microscopy. After treatment with FIAU 400 mg/kg/d for 4 d, chimeric mice developed clinical and serologic evidence of liver failure and lactic acidosis. Analysis of liver tissue revealed steatosis in regions with human, but not mouse, hepatocytes. Electron micrographs revealed lipid and mitochondrial abnormalities in the human hepatocytes in FIAU-treated chimeric mice. Dose-dependent liver toxicity was detected in chimeric mice treated with FIAU 100, 25, or 2.5 mg/kg/d for 14 d. Liver toxicity did not develop in control mice that were treated with the same FIAU doses for 14 d. In contrast, treatment with another nucleotide analogue (sofosbuvir 440 or 44 mg/kg/d po for 14 d, which did not cause liver toxicity in human trial participants, did not cause liver toxicity in mice with humanized livers.FIAU-induced liver toxicity could be readily detected using chimeric TK-NOG mice with humanized livers, even when the mice were treated with a FIAU dose that was only 10-fold above the dose used in human participants. The clinical features, laboratory abnormalities, liver histology, and ultra-structural changes observed in FIAU-treated chimeric mice mirrored those of FIAU-treated human participants. The use of chimeric mice in preclinical toxicology

  13. Fialuridine induces acute liver failure in chimeric TK-NOG mice: a model for detecting hepatic drug toxicity prior to human testing.

    Science.gov (United States)

    Xu, Dan; Nishimura, Toshi; Nishimura, Sachiko; Zhang, Haili; Zheng, Ming; Guo, Ying-Ying; Masek, Marylin; Michie, Sara A; Glenn, Jeffrey; Peltz, Gary

    2014-04-01

    Seven of 15 clinical trial participants treated with a nucleoside analogue (fialuridine [FIAU]) developed acute liver failure. Five treated participants died, and two required a liver transplant. Preclinical toxicology studies in mice, rats, dogs, and primates did not provide any indication that FIAU would be hepatotoxic in humans. Therefore, we investigated whether FIAU-induced liver toxicity could be detected in chimeric TK-NOG mice with humanized livers. Control and chimeric TK-NOG mice with humanized livers were treated orally with FIAU 400, 100, 25, or 2.5 mg/kg/d. The response to drug treatment was evaluated by measuring plasma lactate and liver enzymes, by assessing liver histology, and by electron microscopy. After treatment with FIAU 400 mg/kg/d for 4 d, chimeric mice developed clinical and serologic evidence of liver failure and lactic acidosis. Analysis of liver tissue revealed steatosis in regions with human, but not mouse, hepatocytes. Electron micrographs revealed lipid and mitochondrial abnormalities in the human hepatocytes in FIAU-treated chimeric mice. Dose-dependent liver toxicity was detected in chimeric mice treated with FIAU 100, 25, or 2.5 mg/kg/d for 14 d. Liver toxicity did not develop in control mice that were treated with the same FIAU doses for 14 d. In contrast, treatment with another nucleotide analogue (sofosbuvir 440 or 44 mg/kg/d po) for 14 d, which did not cause liver toxicity in human trial participants, did not cause liver toxicity in mice with humanized livers. FIAU-induced liver toxicity could be readily detected using chimeric TK-NOG mice with humanized livers, even when the mice were treated with a FIAU dose that was only 10-fold above the dose used in human participants. The clinical features, laboratory abnormalities, liver histology, and ultra-structural changes observed in FIAU-treated chimeric mice mirrored those of FIAU-treated human participants. The use of chimeric mice in preclinical toxicology studies could improve

  14. Optical Detection of Ketoprofen by Its Electropolymerization on an Indium Tin Oxide-Coated Optical Fiber Probe.

    Science.gov (United States)

    Bogdanowicz, Robert; Niedziałkowski, Paweł; Sobaszek, Michał; Burnat, Dariusz; Białobrzeska, Wioleta; Cebula, Zofia; Sezemsky, Petr; Koba, Marcin; Stranak, Vitezslav; Ossowski, Tadeusz; Śmietana, Mateusz

    2018-04-27

    In this work an application of optical fiber sensors for real-time optical monitoring of electrochemical deposition of ketoprofen during its anodic oxidation is discussed. The sensors were fabricated by reactive magnetron sputtering of indium tin oxide (ITO) on a 2.5 cm-long core of polymer-clad silica fibers. ITO tuned in optical properties and thickness allows for achieving a lossy-mode resonance (LMR) phenomenon and it can be simultaneously applied as an electrode in an electrochemical setup. The ITO-LMR electrode allows for optical monitoring of changes occurring at the electrode during electrochemical processing. The studies have shown that the ITO-LMR sensor’s spectral response strongly depends on electrochemical modification of its surface by ketoprofen. The effect can be applied for real-time detection of ketoprofen. The obtained sensitivities reached over 1400 nm/M (nm·mg −1 ·L) and 16,400 a.u./M (a.u.·mg −1 ·L) for resonance wavelength and transmission shifts, respectively. The proposed method is a valuable alternative for the analysis of ketoprofen within the concentration range of 0.25⁻250 μg mL −1 , and allows for its determination at therapeutic and toxic levels. The proposed novel sensing approach provides a promising strategy for both optical and electrochemical detection of electrochemical modifications of ITO or its surface by various compounds.

  15. High sensitive detection of copper II ions using D-penicillamine-coated gold nanorods based on localized surface plasmon resonance

    Science.gov (United States)

    Hong, Yoochan; Jo, Seongjae; Park, Joohyung; Park, Jinsung; Yang, Jaemoon

    2018-05-01

    In this paper, we describe the development of a nanoplasmonic biosensor based on the localized surface plasmon resonance (LSPR) effect that enables a sensitive and selective recognition of copper II ions. First, we fabricated the nanoplasmonics as LSPR substrates using gold nanorods (GNR) and the nano-adsorption method. The LSPR sensitivity of the nanoplasmonics was evaluated using various solvents with different refractive indexes. Subsequently, D-penicillamine (DPA)—a chelating agent of copper II ions—was conjugated to the surface of the GNR. The limit of detection (LOD) for the DPA-conjugated nanoplasmonics was 100 pM. Furthermore, selectivity tests were conducted using various divalent cations, and sensitivity tests were conducted on the nanoplasmonics under blood-like environments. Finally, the developed nanoplasmonic biosensor based on GNR shows great potential for the effective recognition of copper II ions, even in human blood conditions.

  16. Iohexol clearance is superior to creatinine-based renal function estimating equations in detecting short-term renal function decline in chronic heart failure.

    Science.gov (United States)

    Cvan Trobec, Katja; Kerec Kos, Mojca; von Haehling, Stephan; Anker, Stefan D; Macdougall, Iain C; Ponikowski, Piotr; Lainscak, Mitja

    2015-12-01

    To compare the performance of iohexol plasma clearance and creatinine-based renal function estimating equations in monitoring longitudinal renal function changes in chronic heart failure (CHF) patients, and to assess the effects of body composition on the equation performance. Iohexol plasma clearance was measured in 43 CHF patients at baseline and after at least 6 months. Simultaneously, renal function was estimated with five creatinine-based equations (four- and six-variable Modification of Diet in Renal Disease, Cockcroft-Gault, Cockcroft-Gault adjusted for lean body mass, Chronic Kidney Disease Epidemiology Collaboration equation) and body composition was assessed using bioimpedance and dual-energy x-ray absorptiometry. Over a median follow-up of 7.5 months (range 6-17 months), iohexol clearance significantly declined (52.8 vs 44.4 mL/[min ×1.73 m2], P=0.001). This decline was significantly higher in patients receiving mineralocorticoid receptor antagonists at baseline (mean decline -22% of baseline value vs -3%, P=0.037). Mean serum creatinine concentration did not change significantly during follow-up and no creatinine-based renal function estimating equation was able to detect the significant longitudinal decline of renal function determined by iohexol clearance. After accounting for body composition, the accuracy of the equations improved, but not their ability to detect renal function decline. Renal function measured with iohexol plasma clearance showed relevant decline in CHF patients, particularly in those treated with mineralocorticoid receptor antagonists. None of the equations for renal function estimation was able to detect these changes. ClinicalTrials.gov registration number: NCT01829880.

  17. Iohexol clearance is superior to creatinine-based renal function estimating equations in detecting short-term renal function decline in chronic heart failure

    Science.gov (United States)

    Cvan Trobec, Katja; Kerec Kos, Mojca; von Haehling, Stephan; Anker, Stefan D.; Macdougall, Iain C.; Ponikowski, Piotr; Lainscak, Mitja

    2015-01-01

    Aim To compare the performance of iohexol plasma clearance and creatinine-based renal function estimating equations in monitoring longitudinal renal function changes in chronic heart failure (CHF) patients, and to assess the effects of body composition on the equation performance. Methods Iohexol plasma clearance was measured in 43 CHF patients at baseline and after at least 6 months. Simultaneously, renal function was estimated with five creatinine-based equations (four- and six-variable Modification of Diet in Renal Disease, Cockcroft-Gault, Cockcroft-Gault adjusted for lean body mass, Chronic Kidney Disease Epidemiology Collaboration equation) and body composition was assessed using bioimpedance and dual-energy x-ray absorptiometry. Results Over a median follow-up of 7.5 months (range 6-17 months), iohexol clearance significantly declined (52.8 vs 44.4 mL/[min ×1.73 m2], P = 0.001). This decline was significantly higher in patients receiving mineralocorticoid receptor antagonists at baseline (mean decline -22% of baseline value vs -3%, P = 0.037). Mean serum creatinine concentration did not change significantly during follow-up and no creatinine-based renal function estimating equation was able to detect the significant longitudinal decline of renal function determined by iohexol clearance. After accounting for body composition, the accuracy of the equations improved, but not their ability to detect renal function decline. Conclusions Renal function measured with iohexol plasma clearance showed relevant decline in CHF patients, particularly in those treated with mineralocorticoid receptor antagonists. None of the equations for renal function estimation was able to detect these changes. ClinicalTrials.gov registration number NCT01829880 PMID:26718759

  18. Oxidation of iridium coating on rhenium coated graphite at elevated temperature in stagnated air

    International Nuclear Information System (INIS)

    Huang, Yongle; Bai, Shuxin; Zhang, Hong; Ye, Yicong

    2015-01-01

    Highlights: • Continuous and dense Ir coatings were prepared on graphite by electrodepostion. • The purification of the as-prepared Ir coating was higher than about 99.98%. • The Ir/Re/C specimen kept integrity without significant failures after oxidation. • The average oxidation rate of the Ir coating was about 0.219 mg/(cm 2 min). • Penetrating holes at gains boundaries resulted in the failure of the Ir coating. - Abstract: Continuous and dense iridium coatings were prepared on the rhenium coated graphite specimens by electrodeposition. The iridium/rhenium coated graphite (Ir/Re/C) specimens were oxidized at elevated temperatures in stagnated air for 3600 s. The purification of the as-prepared Ir coating was higher than about 99.98% with the main impurity elements Si, Al, Fe and Ru. After oxidation, the Ir/Re/C specimens kept integrity without significant failures and the average oxidation rate was about 0.219 mg/(cm 2 min). Pores were found at the grain boundaries and concentrated to penetrating holes with the growth of Ir grains, which resulted in disastrous failures of the Ir coating

  19. Oxidation of iridium coating on rhenium coated graphite at elevated temperature in stagnated air

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Yongle; Bai, Shuxin, E-mail: NUDT_MSE_501@163.com; Zhang, Hong; Ye, Yicong

    2015-02-15

    Highlights: • Continuous and dense Ir coatings were prepared on graphite by electrodepostion. • The purification of the as-prepared Ir coating was higher than about 99.98%. • The Ir/Re/C specimen kept integrity without significant failures after oxidation. • The average oxidation rate of the Ir coating was about 0.219 mg/(cm{sup 2} min). • Penetrating holes at gains boundaries resulted in the failure of the Ir coating. - Abstract: Continuous and dense iridium coatings were prepared on the rhenium coated graphite specimens by electrodeposition. The iridium/rhenium coated graphite (Ir/Re/C) specimens were oxidized at elevated temperatures in stagnated air for 3600 s. The purification of the as-prepared Ir coating was higher than about 99.98% with the main impurity elements Si, Al, Fe and Ru. After oxidation, the Ir/Re/C specimens kept integrity without significant failures and the average oxidation rate was about 0.219 mg/(cm{sup 2} min). Pores were found at the grain boundaries and concentrated to penetrating holes with the growth of Ir grains, which resulted in disastrous failures of the Ir coating.

  20. CD163-Macrophages Are Involved in Rhabdomyolysis-Induced Kidney Injury and May Be Detected by MRI with Targeted Gold-Coated Iron Oxide Nanoparticles.

    Science.gov (United States)

    Rubio-Navarro, Alfonso; Carril, Mónica; Padro, Daniel; Guerrero-Hue, Melanie; Tarín, Carlos; Samaniego, Rafael; Cannata, Pablo; Cano, Ainhoa; Villalobos, Juan Manuel Amaro; Sevillano, Ángel Manuel; Yuste, Claudia; Gutiérrez, Eduardo; Praga, Manuel; Egido, Jesús; Moreno, Juan Antonio

    2016-01-01

    Macrophages play an important role in rhabdomyolysis-acute kidney injury (AKI), although the molecular mechanisms involved in macrophage differentiation are poorly understood. We analyzed the expression and regulation of CD163, a membrane receptor mainly expressed by anti-inflammatory M2 macrophages, in rhabdomyolysis-AKI and developed targeted probes for its specific detection in vivo by MRI. Intramuscular injection of glycerol in mice promoted an early inflammatory response, with elevated proportion of M1 macrophages, and partial differentiation towards a M2 phenotype in later stages, where increased CD163 expression was observed. Immunohistological studies confirmed the presence of CD163-macrophages in human rhabdomyolysis-AKI. In cultured macrophages, myoglobin upregulated CD163 expression via HO-1/IL-10 axis. Moreover, we developed gold-coated iron oxide nanoparticles vectorized with an anti-CD163 antibody that specifically targeted CD163 in kidneys from glycerol-injected mice, as determined by MRI studies, and confirmed by electron microscopy and immunological analysis. Our findings are the first to demonstrate that CD163 is present in both human and experimental rhabdomyolysis-induced AKI, suggesting an important role of this molecule in this pathological condition. Therefore, the use of probes targeting CD163-macrophages by MRI may provide important information about the cellular composition of renal lesion in rhabdomyolysis.

  1. Polymer-coated magnetic nanospheres for preconcentration of organochlorine and pyrethroid pesticides prior to their determination by gas chromatography with electron capture detection

    International Nuclear Information System (INIS)

    Yang, Genggeng; He, Zeying; Liu, Xueke; Liu, Chang; Zhan, Jing; Liu, Donghui; Wang, Peng; Zhou, Zhiqiang

    2016-01-01

    Magnetic polymer nanospheres were prepared and used as adsorbents for the extraction of organochlorine and pyrethroid pesticides from water samples. The adsorbents were synthesized by mini emulsion polymerization of N-vinylimidazole and divinylbenzene and simultaneous encapsulation of oleic acid-coated Fe 3 O 4 nanoparticles. Following desorption with ethyl acetate, the target analytes β-hexachlorocyclohexane, δ-hexachlorocyclohexane, p,p’-DDE, heptachlor, trans-chlordan, cis-chlordan, bifenthrin, β-cypermethrin, δ-methrin, λ-cyhalothrin and esfenvalerate were determined by gas chromatography with electron capture detection. Desorption conditions, extraction times and sample volume were screened by Plackett-Burman design and optimized by Box-Behnken design. Under the optimum conditions, the organochlorines can be quantified in the 20 to 400 ng L −1 concentration range, and the pyrethroids in the 400 to 4000 ng L −1 concentration range. The recoveries of organochlorines and pyrethroids from spiked real water samples are between 77.6 and 97.3 %, with relative standard deviations between 0.9 and 10.0 %. The method for magnetic solid phase extraction described here is fast, simple and friendly to the environment. (author)

  2. Incidence of Lettuce mosaic virus in lettuce and its detection by polyclonal antibodies produced against recombinant coat protein expressed in Escherichia coli.

    Science.gov (United States)

    Sharma, Prachi; Sharma, Susheel; Singh, Jasvir; Saha, Swati; Baranwal, V K

    2016-04-01

    Lettuce mosaic virus (LMV), a member of the genus Potyvirus of family Potyviridae, causes mosaic disease in lettuce has recently been identified in India. The virus is seed borne and secondary infection occurs through aphids. To ensure virus freedom in seeds it is important to develop diagnostic tools, for serological methods the production of polyclonal antibodies is a prerequisite. The coat protein (CP) gene of LMV was amplified, cloned and expressed using pET-28a vector in Escherichia coli BL21DE3 competent cells. The LMV CP was expressed as a fusion protein containing a fragment of the E. coli His tag. The LMV CP/His protein reacted positively with a commercial antiserum against LMV in an immunoblot assay. Polyclonal antibodies purified from serum of rabbits immunized with the fusion protein gave positive results when LMV infected lettuce (Lactuca sativa) was tested at 1:1000 dilution in PTA-ELISA. These were used for specific detection of LMV in screening lettuce accessions. The efficacy of the raised polyclonal antiserum was high and it can be utilized in quarantine and clean seed production. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Sorbent Film-Coated Passive Samplers for Explosives Vapour Detection Part A: Materials Optimisation and Integration with Analytical Technologies.

    Science.gov (United States)

    McEneff, Gillian L; Murphy, Bronagh; Webb, Tony; Wood, Dan; Irlam, Rachel; Mills, Jim; Green, David; Barron, Leon P

    2018-04-11

    A new thin-film passive sampler is presented as a low resource dependent and discrete continuous monitoring solution for explosives-related vapours. Using 15 mid-high vapour pressure explosives-related compounds as probes, combinations of four thermally stable substrates and six film-based sorbents were evaluated. Meta-aramid and phenylene oxide-based materials showed the best recoveries from small voids (~70%). Analysis was performed using liquid chromatography-high resolution accurate mass spectrometry which also enabled tentative identification of new targets from the acquired data. Preliminary uptake kinetics experiments revealed plateau concentrations on the device were reached between 3-5 days. Compounds used in improvised explosive devices, such as triacetone triperoxide, were detected within 1 hour and were stably retained by the sampler for up to 7 days. Sampler performance was consistent for 22 months after manufacture. Lastly, its direct integration with currently in-service explosives screening equipment including ion mobility spectrometry and thermal desorption mass spectrometry is presented. Following exposure to several open environments and targeted interferences, sampler performance was subsequently assessed and potential interferences identified. High-security building and area monitoring for concealed explosives using such cost-effective and discrete passive samplers can add extra assurance to search routines while minimising any additional burden on personnel or everyday site operation.

  4. Contraceptive failure

    DEFF Research Database (Denmark)

    Rasch, Vibeke

    2002-01-01

    Most studies focusing on contraceptive failure in relation to pregnancy have focused on contraceptive failure among women having induced abortions, thereby neglecting those women who, despite contraceptive failure, accept the pregnancy and intend to carry the fetus to term. To get a more complete...... picture of the problem of contraceptive failure, this study focuses on contraceptive failure among women with diverse pregnancy outcomes. In all, 3520 pregnant women attending Odense University Hospital were included: 373 had induced abortions, 435 had spontaneous abortions, 97 had ectopic pregnancies......, and 2614 received antenatal care. The variables studied comprise age, partner relationship, number of births, occupational and economical situation, and contraceptive use.Contraceptive failure, defined as contraceptive use (condom, diaphragm, IUD, oral contraception, or another modern method...

  5. Heart Failure

    OpenAIRE

    McMurray, John; Ponikowski, Piotr

    2011-01-01

    Heart failure occurs in 3% to 4% of adults aged over 65 years, usually as a consequence of coronary artery disease or hypertension, and causes breathlessness, effort intolerance, fluid retention, and increased mortality. The 5-year mortality in people with systolic heart failure ranges from 25% to 75%, often owing to sudden death following ventricular arrhythmia. Risks of cardiovascular events are increased in people with left ventricular systolic dysfunction (LVSD) or heart failure.

  6. Microcystin-LR detection in water by the Fabry-Pérot interferometer using an optical fibre coated with a sol-gel imprinted sensing membrane.

    Science.gov (United States)

    Queirós, Raquel B; Silva, S O; Noronha, J P; Frazão, O; Jorge, P; Aguilar, G; Marques, P V S; Sales, M G F

    2011-05-15

    Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 μg L(-1) of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry-Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol-gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol-gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry-Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3-1.4 μg L(-1) with a sensitivity of -12.4±0.7 nm L μg(-1). The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of -5.9±0.2 nm L μg(-1). The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Evaluating IMRT and VMAT dose accuracy: Practical examples of failure to detect systematic errors when applying a commonly used metric and action levels

    Energy Technology Data Exchange (ETDEWEB)

    Nelms, Benjamin E. [Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States); Chan, Maria F. [Memorial Sloan-Kettering Cancer Center, Basking Ridge, New Jersey 07920 (United States); Jarry, Geneviève; Lemire, Matthieu [Hôpital Maisonneuve-Rosemont, Montréal, QC H1T 2M4 (Canada); Lowden, John [Indiana University Health - Goshen Hospital, Goshen, Indiana 46526 (United States); Hampton, Carnell [Levine Cancer Institute/Carolinas Medical Center, Concord, North Carolina 28025 (United States); Feygelman, Vladimir [Moffitt Cancer Center, Tampa, Florida 33612 (United States)

    2013-11-15

    Purpose: This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detailing these case studies is to explore different, more sensitive methods and metrics that could be used more effectively for evaluating accuracy of dose algorithms, delivery systems, and QA devices.Methods: The authors present seven real-world case studies representing a variety of combinations of the treatment planning system (TPS), linac, delivery modality, and systematic error type. These case studies are typical to what might be used as part of an IMRT or VMAT commissioning test suite, varying in complexity. Each case study is analyzed according to TG-119 instructions for gamma passing rates and action levels for per-beam and/or composite plan dosimetric QA. Then, each case study is analyzed in-depth with advanced diagnostic methods (dose profile examination, EPID-based measurements, dose difference pattern analysis, 3D measurement-guided dose reconstruction, and dose grid inspection) and more sensitive metrics (2% local normalization/2 mm DTA and estimated DVH comparisons).Results: For these case studies, the conventional 3%/3 mm gamma passing rates exceeded 99% for IMRT per-beam analyses and ranged from 93.9% to 100% for composite plan dose analysis, well above the TG-119 action levels of 90% and 88%, respectively. However, all cases had systematic errors that were detected only by using advanced diagnostic techniques and more sensitive metrics. The systematic errors caused variable but noteworthy impact, including estimated target dose coverage loss of up to 5.5% and local dose deviations up to 31.5%. Types of errors included TPS model settings, algorithm limitations, and modeling and alignment of QA phantoms in the TPS. Most of the errors were

  8. Sensor Failure Detection through Introspection

    National Research Council Canada - National Science Library

    Smeltz, Jeremy; Valerius, Andrew

    2007-01-01

    .... One area of research being done is simultaneous localization and mapping (SLAM). SLAM uses a robot's sensors to generate a map of the area while maintaining its current position within that map...

  9. Immuno-Spin Trapping-Based Detection of Oxidative Modifications in Cardiomyocytes and Coronary Endothelium in the Progression of Heart Failure in Tgαq*44 Mice

    Directory of Open Access Journals (Sweden)

    Bartosz Proniewski

    2018-05-01

    Full Text Available Recent studies suggest both beneficial and detrimental role of increased reactive oxygen species and oxidative stress in heart failure (HF. However, it is not clear at which stage oxidative stress and oxidative modifications occur in the endothelium in relation to cardiomyocytes in non-ischemic HF. Furthermore, most methods used to date to study oxidative stress are either non-specific or require tissue homogenization. In this study, we used immuno-spin trapping (IST technique with fluorescent microscopy-based detection of DMPO nitrone adducts to localize and quantify oxidative modifications of the hearts from Tgαq*44 mice; a murine model of HF driven by cardiomyocyte-specific overexpression of Gαq* protein. Tgαq*44 mice and age-matched FVB controls at early, transition, and late stages of HF progression were injected with DMPO in vivo and analyzed ex vivo for DMPO nitrone adducts signals. Progressive oxidative modifications in cardiomyocytes, as evidenced by the elevation of DMPO nitrone adducts, were detected in hearts from 10- to 16-month-old, but not in 8-month-old Tgαq*44 mice, as compared with age-matched FVB mice. The DMPO nitrone adducts were detected in left and right ventricle, septum, and papillary muscle. Surprisingly, significant elevation of DMPO nitrone adducts was also present in the coronary endothelium both in large arteries and in microcirculation simultaneously, as in cardiomyocytes, starting from 10-month-old Tgαq*44 mice. On the other hand, superoxide production in heart homogenates was elevated already in 6-month-old Tgαq*44 mice and progressively increased to high levels in 14-month-old Tgαq*44 mice, while the enzymatic activity of catalase, glutathione reductase, and glutathione peroxidase was all elevated as early as in 4-month-old Tgαq*44 mice and stayed at a similar level in 14-month-old Tgαq*44. In summary, this study demonstrates that IST represents a unique method that allows to quantify oxidative

  10. Failure Analysis of Alumina Reinforced Aluminum Microtruss and Tube Composites

    Science.gov (United States)

    Chien, Hsueh Fen (Karen)

    The energy absorption capacity of cellular materials can be dramatically increased by applying a structural coating. This thesis examined the failure mechanisms of alumina reinforced 3003 aluminum alloy microtrusses and tubes. Alumina coatings were produced by hard anodizing and by plasma electrolytic oxidation (PEO). The relatively thin and discontinuous oxide coating at the hinge acted as a localized weak spot which triggered a chain reaction of failure, including oxide fracture, oxide spallation, oxide penetration to the aluminum core and severe local plastic deformation of the core. For the PEO microtrusses, delamination occurred within the oxide coating resulting in a global strut buckling failure mode. A new failure mode for the anodized tubes was observed: (i) axisymmetric folding of the aluminum core, (ii) longitudinal fracture, and (iii) alumina pulverization. Overall, the alumina coating enhanced the buckling resistance of the composites, while the aluminum core supported the oxide during the damage propagation.

  11. Inverter ratio failure detector

    Science.gov (United States)

    Wagner, A. P.; Ebersole, T. J.; Andrews, R. E. (Inventor)

    1974-01-01

    A failure detector which detects the failure of a dc to ac inverter is disclosed. The inverter under failureless conditions is characterized by a known linear relationship of its input and output voltages and by a known linear relationship of its input and output currents. The detector includes circuitry which is responsive to the detector's input and output voltages and which provides a failure-indicating signal only when the monitored output voltage is less by a selected factor, than the expected output voltage for the monitored input voltage, based on the known voltages' relationship. Similarly, the detector includes circuitry which is responsive to the input and output currents and provides a failure-indicating signal only when the input current exceeds by a selected factor the expected input current for the monitored output current based on the known currents' relationship.

  12. Mixed hemimicelles solid-phase extraction based on sodium dodecyl sulfate-coated nano-magnets for selective adsorption and enrichment of illegal cationic dyes in food matrices prior to high-performance liquid chromatography-diode array detection detection.

    Science.gov (United States)

    Qi, Ping; Liang, Zhi-An; Wang, Yu; Xiao, Jian; Liu, Jia; Zhou, Qing-Qiong; Zheng, Chun-Hao; Luo, Li-Ni; Lin, Zi-Hao; Zhu, Fang; Zhang, Xue-Wu

    2016-03-11

    In this study, mixed hemimicelles solid-phase extraction (MHSPE) based on sodium dodecyl sulfate (SDS) coated nano-magnets Fe3O4 was investigated as a novel method for the extraction and separation of four banned cationic dyes, Auramine O, Rhodamine B, Basic orange 21 and Basic orange 22, in condiments prior to HPLC detection. The main factors affecting the extraction of analysts, such as pH, surfactant and adsorbent concentrations and zeta potential were studied and optimized. Under optimized conditions, the proposed method was successful applied for the analysis of banned cationic dyes in food samples such as chili sauce, soybean paste and tomato sauce. Validation data showed the good recoveries in the range of 70.1-104.5%, with relative standard deviations less than 15%. The method limits of determination/quantification were in the range of 0.2-0.9 and 0.7-3μgkg(-1), respectively. The selective adsorption and enrichment of cationic dyes were achieved by the synergistic effects of hydrophobic interactions and electrostatic attraction between mixed hemimicelles and the cationic dyes, which also resulted in the removal of natural pigments interferences from sample extracts. When applied to real samples, RB was detected in several positive samples (chili powders) within the range from 0.042 to 0.177mgkg(-1). These results indicate that magnetic MHSPE is an efficient and selective sample preparation technique for the extraction of banned cationic dyes in a complex matrix. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Heart Failure

    Science.gov (United States)

    ... Other diseases. Chronic diseases — such as diabetes, HIV, hyperthyroidism, hypothyroidism, or a buildup of iron (hemochromatosis) or ... transplantation or support with a ventricular assist device. Prevention The key to preventing heart failure is to ...

  14. Hard coatings

    International Nuclear Information System (INIS)

    Dan, J.P.; Boving, H.J.; Hintermann, H.E.

    1993-01-01

    Hard, wear resistant and low friction coatings are presently produced on a world-wide basis, by different processes such as electrochemical or electroless methods, spray technologies, thermochemical, CVD and PVD. Some of the most advanced processes, especially those dedicated to thin film depositions, basically belong to CVD or PVD technologies, and will be looked at in more detail. The hard coatings mainly consist of oxides, nitrides, carbides, borides or carbon. Over the years, many processes have been developed which are variations and/or combinations of the basic CVD and PVD methods. The main difference between these two families of deposition techniques is that the CVD is an elevated temperature process (≥ 700 C), while the PVD on the contrary, is rather a low temperature process (≤ 500 C); this of course influences the choice of substrates and properties of the coating/substrate systems. Fundamental aspects of the vapor phase deposition techniques and some of their influences on coating properties will be discussed, as well as the very important interactions between deposit and substrate: diffusions, internal stress, etc. Advantages and limitations of CVD and PVD respectively will briefly be reviewed and examples of applications of the layers will be given. Parallel to the development and permanent updating of surface modification technologies, an effort was made to create novel characterisation methods. A close look will be given to the coating adherence control by means of the scratch test, at the coating hardness measurement by means of nanoindentation, at the coating wear resistance by means of a pin-on-disc tribometer, and at the surface quality evaluation by Atomic Force Microscopy (AFM). Finally, main important trends will be highlighted. (orig.)

  15. Informing the Design of "Lifestyle Monitoring" Technology for the Detection of Health Deterioration in Long-Term Conditions: A Qualitative Study of People Living With Heart Failure.

    Science.gov (United States)

    Hargreaves, Sarah; Hawley, Mark S; Haywood, Annette; Enderby, Pamela M

    2017-06-28

    Health technologies are being developed to help people living at home manage long-term conditions. One such technology is "lifestyle monitoring" (LM), a telecare technology based on the idea that home activities may be monitored unobtrusively via sensors to give an indication of changes in health-state. However, questions remain about LM technology: how home activities change when participants experience differing health-states; and how sensors might capture clinically important changes to inform timely interventions. The objective of this paper was to report the findings of a study aimed at identifying changes in activity indicative of important changes in health in people with long-term conditions, particularly changes indicative of exacerbation, by exploring the relationship between home activities and health among people with heart failure (HF). We aimed to add to the knowledge base informing the development of home monitoring technologies designed to detect health deterioration in order to facilitate early intervention and avoid hospital admissions. This qualitative study utilized semistructured interviews to explore everyday activities undertaken during the three health-states of HF: normal days, bad days, and exacerbations. Potential recruits were identified by specialist nurses and attendees at an HF support group. The sample was purposively selected to include a range of experience of living with HF. The sample comprised a total of 20 people with HF aged 50 years and above, and 11 spouses or partners of the individuals with HF. All resided in Northern England. Participant accounts revealed that home activities are in part shaped by the degree of intrusion from HF symptoms. During an exacerbation, participants undertook activities specifically to ease symptoms, and detailed activity changes were identified. Everyday activity was also influenced by a range of factors other than health. The study highlights the importance of careful development of LM

  16. One-pot synthesis of zeolitic imidazolate framework-8/poly (methyl methacrylate-ethyleneglycol dimethacrylate) monolith coating for stir bar sorptive extraction of phytohormones from fruit samples followed by high performance liquid chromatography-ultraviolet detection.

    Science.gov (United States)

    You, Linna; He, Man; Chen, Beibei; Hu, Bin

    2017-11-17

    In this work, zeolitic imidazolate framework-8 (ZIF-8)/poly (methyl methacrylate-ethyleneglycol dimethacrylate) (MMA-EGDMA) composite monolith was in situ synthesized on stir bar by one-pot polymerization. Compared with the neat monolith, ZIF-8/poly(MMA-EGDMA) composite monolith has larger surface area and pore volume. It also exhibits higher extraction efficiency for target phytohormones than poly(MMA-EGDMA) monolith and commercial polyethylene glycol (PEG) coated stir bar. Based on it, a method of ZIF-8/poly(MMA-EGDMA) monolith coated stir bar sorptive extraction (SBSE)-high performance liquid chromatography-ultraviolet detection (HPLC-UV) was established for the analysis of five phytohormones in apple and pear samples. The developed method exhibited low limits of detection (0.11-0.51μg/L), wide linear range (0.5-500μg/L) and good recoveries (82.7-111%), which demonstrated good application potential of the ZIF-8/monolith coated stir bar in trace analysis of organic compounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Detection and control of as-produced pyrocarbon permeability in biso-coated high-temperature gas-cooled reactor fuel particles

    International Nuclear Information System (INIS)

    Stinton, D.P.; Thiele, B.A.; Lackey, W.J.; Morgan, C.S.

    1980-05-01

    About 60 Biso-coated particle batches with coatings deposited in either 0.13- or 0.24-m dia coaters were studied in this work. These batches were carefully characterized for permeability by neon-helium intrusion, long-term chlorination followed by radiography, and fission gas release. These methods of permeability measurement were compared and correlated with deposition conditions as well as pyrocarbon properties. The results from several irradiation tests were also used to evaluate the validity of the permeability measurements. The neon-helium and long-term chlorination techniques correlated very clearly. Coatings with neon-to-helium ratios below 0.3 were gastight by the chlorination procedure, whereas those with ratios above 0.4 were permeable. The fission gas release technique was unable to distinguish between slightly permeable coatings and gastight ones. Therefore, neon-helium and long-term chlorination procedures are preferred over the fission gas release technique. Results from several irradiation tests verified that coatings with neon-to-helium ratios below 0.3 were gastight, whereas those with ratios above about 0.4 were permeable. 10 figures, 2 tables

  18. Detection of volatile organic compounds using an optical fiber sensor coated with a sol-gel silica layer containing immobilized Nile red

    Science.gov (United States)

    Liu, Dejun; Lian, Xiaokang; Mallik, Arun Kumar; Han, Wei; Wei, Fangfang; Yuan, Jinhui; Yu, Chongxiu; Farrell, Gerald; Semenova, Yuliya; Wu, Qiang

    2017-04-01

    A simple volatile organic compound (VOC) sensor based on a tapered small core singlemode fiber (SCSMF) structure is reported. The tapered SCSMF fiber structure with a waist diameter of 7.0 μm is fabricated using a customized microheater brushing technique. Silica based material containing immobilized Nile red was prepared by a sol-gel method and was used as a coating applied to the surface of the tapered fiber structure. Different coating thicknesses created by a 2-pass and 4-pass coating process are investigated. The experiments demonstrate that both sensors show a linear response at different gas concentrations to all three tested VOCs (methanol, ethanol and acetone). The sensor with a thicker coating shows better sensitivities but longer response and recovery times. The best measurement resolutions for the 4-pass coating sensor are estimated to be 2.3 ppm, 1.5 ppm and 3.1 ppm for methanol, ethanol and acetone, respectively. The fastest response and recovery time of 1 min and 5 min are demonstrated by the sensor in the case of methanol.

  19. Smart Coatings for Corrosion Protection

    Science.gov (United States)

    Calle, Luz Marina; Li, Wendy; Buhrow, Jerry W.; Johnsey, Marissa N.

    2016-01-01

    Nearly all metals and their alloys are subject to corrosion that causes them to lose their structural integrity or other critical functionality. It is essential to detect corrosion when it occurs, and preferably at its early stage, so that action can be taken to avoid structural damage or loss of function. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to indicate it and control it.

  20. Protective Coatings

    Science.gov (United States)

    1980-01-01

    General Magnaplate Corporation's pharmaceutical machine is used in the industry for high speed pressing of pills and capsules. Machine is automatic system for molding glycerine suppositories. These machines are typical of many types of drug production and packaging equipment whose metal parts are treated with space spinoff coatings that promote general machine efficiency and contribute to compliance with stringent federal sanitation codes for pharmaceutical manufacture. Collectively known as "synergistic" coatings, these dry lubricants are bonded to a variety of metals to form an extremely hard slippery surface with long lasting self lubrication. The coatings offer multiple advantages; they cannot chip, peel or be rubbed off. They protect machine parts from corrosion and wear longer, lowering maintenance cost and reduce undesired heat caused by power-robbing friction.

  1. Thermophysical and Thermomechanical Properties of Thermal Barrier Coating Systems

    Science.gov (United States)

    Zhu, Dongming; Miller, Robert A.

    2000-01-01

    Thermal barrier coatings have been developed for advanced gas turbine and diesel engine applications to improve engine reliability and fuel efficiency. However, the issue of coating durability under high temperature cyclic conditions is still of major concern. The coating failure is closely related to thermal stresses and oxidation in the coating systems. Coating shrinkage cracking resulting from ceramic sintering and creep at high temperatures can further accelerate the coating failure process. The purpose of this paper is to address critical issues such as ceramic sintering and creep, thermal fatigue and their relevance to coating life prediction. Novel test approaches have been established to obtain critical thermophysical and thermomechanical properties of the coating systems under near-realistic temperature and stress gradients encountered in advanced engine systems. Emphasis is placed on the dynamic changes of the coating thermal conductivity and elastic modulus, fatigue and creep interactions, and resulting failure mechanisms during the simulated engine tests. Detailed experimental and modeling results describing processes occurring in the thermal barrier coating systems provide a framework for developing strategies to manage ceramic coating architecture, microstructure and properties.

  2. Superior sealing effect of hydroxyapatite in porous-coated implants

    DEFF Research Database (Denmark)

    Rahbek, Ole; Kold, Søren; Bendix, Knud

    2005-01-01

    Migration of wear debris to the periprosthetic bone is a major cause of osteolysis and implant failure. Both closed-pore porous coatings and hydroxyapatite (HA) coatings have been claimed to prevent the migration of wear debris. We investigated whether HA could augment the sealing effect of a por......Migration of wear debris to the periprosthetic bone is a major cause of osteolysis and implant failure. Both closed-pore porous coatings and hydroxyapatite (HA) coatings have been claimed to prevent the migration of wear debris. We investigated whether HA could augment the sealing effect...

  3. In vitro mechanical integrity of hydroxyapatite coated magnesium alloy

    International Nuclear Information System (INIS)

    Kannan, M Bobby; Orr, Lynnley

    2011-01-01

    The mechanical integrity of resorbable implants during service, especially in load bearing orthopaedic applications, is critical. The high degradation rate of resorbable magnesium and magnesium-based implants in body fluid may potentially cause premature in-service failure. In this study, a magnesium alloy (AZ91) was potentiostatically coated with hydroxyapatite at different cathodic voltages in an attempt to enhance the mechanical integrity. The mechanical integrity of the uncoated and hydroxyapatite coated alloys was evaluated after in vitro testing of the coated samples in simulated body fluid (SBF). The uncoated alloy showed 40% loss in the mechanical strength after five days exposure to SBF. However, the hydroxyapatite coated alloy exposed to SBF showed 20% improvement in the mechanical strength as compared to that of the uncoated alloy. The alloy coated potentiostatically at -2 V performed better than the -3 V coated alloy. The cross-sectional analysis of the coatings revealed relatively uniform coating thickness for the -2 V coated alloy, whereas the -3 V coated alloy exhibited areas of uneven coating. This can be attributed to the increase in hydrogen evolution on the alloy during -3 V coating as compared to -2 V coating. The scanning electron micrographs of the in vitro tested alloy revealed that hydroxyapatite coating significantly reduced the localized corrosion of the alloy, which is critical for better in-service mechanical integrity. Thus, the study suggests that the in vitro mechanical integrity of resorbable magnesium-based alloy can be improved by potentiostatic hydroxyapatite coating.

  4. In vitro mechanical integrity of hydroxyapatite coated magnesium alloy.

    Science.gov (United States)

    Kannan, M Bobby; Orr, Lynnley

    2011-08-01

    The mechanical integrity of resorbable implants during service, especially in load bearing orthopaedic applications, is critical. The high degradation rate of resorbable magnesium and magnesium-based implants in body fluid may potentially cause premature in-service failure. In this study, a magnesium alloy (AZ91) was potentiostatically coated with hydroxyapatite at different cathodic voltages in an attempt to enhance the mechanical integrity. The mechanical integrity of the uncoated and hydroxyapatite coated alloys was evaluated after in vitro testing of the coated samples in simulated body fluid (SBF). The uncoated alloy showed 40% loss in the mechanical strength after five days exposure to SBF. However, the hydroxyapatite coated alloy exposed to SBF showed 20% improvement in the mechanical strength as compared to that of the uncoated alloy. The alloy coated potentiostatically at -2 V performed better than the -3 V coated alloy. The cross-sectional analysis of the coatings revealed relatively uniform coating thickness for the -2 V coated alloy, whereas the -3 V coated alloy exhibited areas of uneven coating. This can be attributed to the increase in hydrogen evolution on the alloy during -3 V coating as compared to -2 V coating. The scanning electron micrographs of the in vitro tested alloy revealed that hydroxyapatite coating significantly reduced the localized corrosion of the alloy, which is critical for better in-service mechanical integrity. Thus, the study suggests that the in vitro mechanical integrity of resorbable magnesium-based alloy can be improved by potentiostatic hydroxyapatite coating. © 2011 IOP Publishing Ltd

  5. In vitro mechanical integrity of hydroxyapatite coated magnesium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, M Bobby; Orr, Lynnley, E-mail: bobby.mathan@jcu.edu.au [Discipline of Chemical Engineering, School of Engineering and Physical Sciences, James Cook University, Townsville, Queensland 4811 (Australia)

    2011-08-15

    The mechanical integrity of resorbable implants during service, especially in load bearing orthopaedic applications, is critical. The high degradation rate of resorbable magnesium and magnesium-based implants in body fluid may potentially cause premature in-service failure. In this study, a magnesium alloy (AZ91) was potentiostatically coated with hydroxyapatite at different cathodic voltages in an attempt to enhance the mechanical integrity. The mechanical integrity of the uncoated and hydroxyapatite coated alloys was evaluated after in vitro testing of the coated samples in simulated body fluid (SBF). The uncoated alloy showed 40% loss in the mechanical strength after five days exposure to SBF. However, the hydroxyapatite coated alloy exposed to SBF showed 20% improvement in the mechanical strength as compared to that of the uncoated alloy. The alloy coated potentiostatically at -2 V performed better than the -3 V coated alloy. The cross-sectional analysis of the coatings revealed relatively uniform coating thickness for the -2 V coated alloy, whereas the -3 V coated alloy exhibited areas of uneven coating. This can be attributed to the increase in hydrogen evolution on the alloy during -3 V coating as compared to -2 V coating. The scanning electron micrographs of the in vitro tested alloy revealed that hydroxyapatite coating significantly reduced the localized corrosion of the alloy, which is critical for better in-service mechanical integrity. Thus, the study suggests that the in vitro mechanical integrity of resorbable magnesium-based alloy can be improved by potentiostatic hydroxyapatite coating.

  6. The ability of NT-proBNP to detect chronic heart failure and predict all-cause mortality is higher in elderly Chinese coronary artery disease patients with chronic kidney disease

    OpenAIRE

    Fu, Shihui; Yi,Shuangyan; Liu,Yuan; Zhu,Bing; Wang,Liang; Tiehui Xiao,; Bai,Yongyi; Ye,Ping; Luo,Leiming

    2013-01-01

    Shihui Fu, Leiming Luo, Ping Ye, Shuangyan Yi, Yuan Liu, Bing Zhu, Liang Wang, Tiehui Xiao, Yongyi Bai Department of Geriatric Cardiology, Chinese PLA General Hospital, Beijing, People's Republic of China Objective: To analyze the relationship between N-terminal pro-brain natriuretic peptide (NT-proBNP) and renal function, and compare the ability and cut-off thresholds of NT-proBNP to detect chronic heart failure (CHF) and predict mortality in elderly Chinese coronary artery disease ...

  7. A Multifunctional Coating for Autonomous Corrosion Control

    Science.gov (United States)

    Calle, Luz M.; Li, Wenyan; Buhrow, Jerry W.; Jolley, Scott t.

    2011-01-01

    Nearly all metals and their alloys are subject to corrosion that causes them to lose their structural integrity or other critical functionality. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to indicate it and control it. The multi-functionality of the coating is based on microencapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of existing microcapsulation designs, the corrosion controlled release function that triggers the delivery of corrosion indicators and inhibitors on demand, only when and where needed. Microencapsulation of self-healing agents for autonomous repair of mechanical damage to the coating is also being pursued. Corrosion indicators, corrosion inhibitors, as well as self-healing agents, have been encapsulated and dispersed into several paint systems to test the corrosion detection, inhibition, and self-healing properties of the coating. Key words: Corrosion, coating, autonomous corrosion control, corrosion indication, corrosion inhibition, self-healing coating, smart coating, multifunctional coating, microencapsulation.

  8. The strength and failure of silica optical fibers

    International Nuclear Information System (INIS)

    Yan, C; Bai, R X; Yu, H; Canning, J; Law, S

    2010-01-01

    The mechanical strength and failure behavior of conventional and microstructured silica optical fibers was investigated using a tensile test and fracture mechanics and numerical analyses. The effect of polymer coating on failure behavior was also studied. The results indicate that all these fibers fail in a brittle manner and failure normally starts from fiber surfaces. The failure loads observed in coated fibers are higher than those in bare fibers. The introduction of air holes reduces fiber strength and their geometrical arrangements have a remarkable effect on stress distribution in the longitudinal direction. These results are potentially useful for the design, fabrication and evaluation of optical fibers for a wide range of applications.

  9. Failure Modes

    DEFF Research Database (Denmark)

    Jakobsen, K. P.; Burcharth, H. F.; Ibsen, Lars Bo

    1999-01-01

    The present appendix contains the derivation of ten different limit state equations divided on three different failure modes. Five of the limit state equations can be used independently of the characteristics of the subsoil, whereas the remaining five can be used for either drained or undrained s...

  10. Types of Heart Failure

    Science.gov (United States)

    ... Introduction Types of Heart Failure Classes of Heart Failure Heart Failure in Children Advanced Heart Failure • Causes and ... and procedures related to heart disease and stroke. Heart Failure Questions to Ask Your Doctor Use these questions ...

  11. Classes of Heart Failure

    Science.gov (United States)

    ... Introduction Types of Heart Failure Classes of Heart Failure Heart Failure in Children Advanced Heart Failure • Causes and ... and Advanced HF • Tools and Resources • Personal Stories Heart Failure Questions to Ask Your Doctor Use these questions ...

  12. U.S. Department Of Energy's nuclear engineering education research: highlights of recent and current research-III. 4. Early Detection of Plant Equipment Failures: A Case Study in Just-In-Time Maintenance

    International Nuclear Information System (INIS)

    Parlos, Alexander G.; Kim, Kyusung; Bharadwaj, Raj M.

    2001-01-01

    Approximately 60% of all incipient electric motor failures is attributed to mechanical and electromechanical causes, whereas 33% of all motor failures is attributed to faults related to motor winding insulation. There has been much research reported on the detection and diagnosis of incipient motor failures. The most widely accepted approach for detection of mechanical failures is vibration monitoring, whereas motor current monitoring is used for electromechanical faults such as broken rotor bars and end-rings. In this paper, the development and testing of a model-based fault detection system for electric motors is briefly presented. In particular, the presented fault detection system has been developed using only motor nameplate information. Furthermore, the fault detection results presented utilize only motor voltage and current sensor information, minimizing the need for expensive or intrusive sensors. In this study, dynamic recurrent neural networks are used to predict the input-output response of a three-phase induction motor while using an estimate of the motor speed signal. Accurate state filtering of the motor speed using only electrical measurements is feasible, and it has been demonstrated in other recent publications. The developed input-output motor model requires no knowledge of the motor specifics; rather, only motor nameplate information is used. The resulting model appears very effective in accurately predicting the dynamic behavior of the nonlinear motor system to varying supply unbalance and load levels. The motor model is then used to generate the residuals needed in the fault diagnosis system. Following the residual generation step, fault detection must be pursued by appropriately processing the residuals. It is common to first extract features characteristic of the faults being investigated prior to attempting fault detection. In this study, multi-resolution (or wavelet) signal-processing techniques are used in combination with more traditional

  13. Cavitation Erosion of Plasma -sprayed Coatings

    International Nuclear Information System (INIS)

    Kim, J. J.; Park, J. S.; Jeon, S. B.

    1991-01-01

    Tungsten Carbide, chromium carbide and chromium oxide coatings were obtained on a 304 stainless steel substrate by plasma spraying technique. The coated samples were exposed to cavitation generated in distilled water by a 20KHz ultrasonic horn. The results of investigation reveal that all the samples tested are significantly eroded even within ten minutes of exposure, indicative of a short incubation period. The eroded surfaces can be characterized as having large pits and flat smooth areas. The latter may be associated with the poor cohesive strength of the coatings, which leads to the failures between individual lamellae

  14. Determination of the DBTT of Aluminide Coatings and its Influence on the Mechanical Behavior of Coated Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Dryepondt, Sebastien N [ORNL; Pint, Bruce A [ORNL

    2010-01-01

    The ductility of various coatings deposited by chemical vapor deposition, pack cementation and slurry processes on Fe- and Ni-based alloys was characterized by indentation at room temperature. A hot indentation apparatus has also been developed to more rapidly determine the ductile to brittle transition temperature of coated specimens. Creep testing has been conducted on bare and coated alloy 230 (NiCrW) specimens at 800 C with a significant decrease in creep life observed. Based on the observed failure of coated 230 specimens, the impact of coating ductility on substrate creep properties is discussed.

  15. Failure Analysis

    International Nuclear Information System (INIS)

    Iorio, A.F.; Crespi, J.C.

    1987-01-01

    After ten years of operation at the Atucha I Nuclear Power Station a gear belonging to a pressurized heavy water reactor refuelling machine, failed. The gear box was used to operate the inlet-outlet heavy-water valve of the machine. Visual examination of the gear device showed an absence of lubricant and that several gear teeth were broken at the root. Motion was transmitted with a speed-reducing device with controlled adjustable times in order to produce a proper fitness of the valve closure. The aim of this paper is to discuss the results of the gear failure analysis in order to recommend the proper solution to prevent further failures. (Author)

  16. Characterization of the behavior of three definitions of prostate-specific antigen-based biochemical failure in relation to detection and follow-up biases: comparison with the American Society for Therapeutic Radiology and Oncology consensus definition.

    Science.gov (United States)

    Williams, Scott G

    2006-03-01

    To examine the impact of detection biases on three prostate cancer biochemical failure (bF) definitions in comparison with the existing American Society for Therapeutic Radiology and Oncology Consensus Definition (ACD). Three alternative bF definitions were tested against the ACD: three rises in prostate-specific antigen (PSA) level without backdating, nadir plus 2 ng/mL, and a threshold PSA level of >3 ng/mL, according to data from 1050 men. The mean time between PSA tests (MTBT), regularity of collection, and calendar year of analysis were examined in each bF definition. The MTBT produced a statistically significant difference in the derived hazard ratio for identification of bF in all definitions. The influence of test regularity was statistically significant beyond the median level of regularity in all definitions. The year of analysis impacted greatly on the ACD, whereas the three alternative definitions exhibited minor follow-up duration variations by comparison. The alternative definitions had reliable follow-up when the crude median time to censoring was at least 1.6 times greater than that of failure. Detection biases will always be a significant issue in defining bF. A number of alternative failure definitions have more predictable interactions with these biases than the existing ACD.

  17. Characterization of the behavior of three definitions of prostate-specific antigen-based biochemical failure in relation to detection and follow-up biases: Comparison with the American Society for Therapeutic Radiology and Oncology consensus definition

    International Nuclear Information System (INIS)

    Williams, Scott G.

    2006-01-01

    Purpose: To examine the impact of detection biases on three prostate cancer biochemical failure (bF) definitions in comparison with the existing American Society for Therapeutic Radiology and Oncology Consensus Definition (ACD). Methods and Materials: Three alternative bF definitions were tested against the ACD: three rises in prostate-specific antigen (PSA) level without backdating, nadir plus 2 ng/mL, and a threshold PSA level of >3 ng/mL, according to data from 1050 men. The mean time between PSA tests (MTBT), regularity of collection, and calendar year of analysis were examined in each bF definition. Results: The MTBT produced a statistically significant difference in the derived hazard ratio for identification of bF in all definitions. The influence of test regularity was statistically significant beyond the median level of regularity in all definitions. The year of analysis impacted greatly on the ACD, whereas the three alternative definitions exhibited minor follow-up duration variations by comparison. The alternative definitions had reliable follow-up when the crude median time to censoring was at least 1.6 times greater than that of failure. Conclusions: Detection biases will always be a significant issue in defining bF. A number of alternative failure definitions have more predictable interactions with these biases than the existing ACD

  18. Effect of secondary organic aerosol coating thickness on the real-time detection and characterization of biomass-burning soot by two particle mass spectrometers

    Directory of Open Access Journals (Sweden)

    A. T. Ahern

    2016-12-01

    Full Text Available Biomass burning is a large source of light-absorbing refractory black carbon (rBC particles with a wide range of morphologies and sizes. The net radiative forcing from these particles is strongly dependent on the amount and composition of non-light-absorbing material internally mixed with the rBC and on the morphology of the mixed particles. Understanding how the mixing state and morphology of biomass-burning aerosol evolves in the atmosphere is critical for constraining the influence of these particles on radiative forcing and climate. We investigated the response of two commercial laser-based particle mass spectrometers, the vacuum ultraviolet (VUV ablation LAAPTOF and the IR vaporization SP-AMS, to monodisperse biomass-burning particles as we sequentially coated the particles with secondary organic aerosol (SOA from α-pinene ozonolysis. We studied three mobility-selected soot core sizes, each with a number of successively thicker coatings of SOA applied. Using IR laser vaporization, the SP-AMS had different changes in sensitivity to rBC compared to potassium as a function of applied SOA coatings. We show that this is due to different effective beam widths for the IR laser vaporization region of potassium versus black carbon. The SP-AMS's sensitivity to black carbon (BC mass was not observed to plateau following successive SOA coatings, despite achieving high OA : BC mass ratios greater than 9. We also measured the ion fragmentation pattern of biomass-burning rBC and found it changed only slightly with increasing SOA mass. The average organic matter ion signal measured by the LAAPTOF demonstrated a positive correlation with the condensed SOA mass on individual particles, despite the inhomogeneity of the particle core compositions. This demonstrates that the LAAPTOF can obtain quantitative mass measurements of aged soot-particle composition from realistic biomass-burning particles with complex morphologies and composition.

  19. Sorptive extraction using polydimethylsiloxane/metal-organic framework coated stir bars coupled with high performance liquid chromatography-fluorescence detection for the determination of polycyclic aromatic hydrocarbons in environmental water samples.

    Science.gov (United States)

    Hu, Cong; He, Man; Chen, Beibei; Zhong, Cheng; Hu, Bin

    2014-08-22

    In this work, metal-organic frameworks (MOFs, Al-MIL-53-NH₂) were synthesized via the hydrothermal method, and novel polydimethylsiloxane/metal-organic framework (PDMS/MOFs, PDMS/Al-MIL-53-NH₂)-coated stir bars were prepared by the sol-gel technique. The preparation reproducibility of the PDMS/MOFs-coated stir bar was good, with relative standard deviations (RSDs) ranging from 4.8% to 14.9% (n=7) within one batch and from 6.2% to 16.9% (n=6) among different batches. Based on this fact, a new method of PDMS/MOFs-coated stir bar sorptive extraction (SBSE) and ultrasonic-assisted liquid desorption (UALD) coupled with high performance liquid chromatography-fluorescence detection (HPLC-FLD) was developed for the determination of polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. To obtain the best extraction performance for PAHs, several parameters affecting SBSE, such as extraction time, stirring rate, and extraction temperature, were investigated. Under optimal experimental conditions, wide linear ranges and good RSDs (n=7) were obtained. With enrichment factors (EFs) of 16.1- to 88.9-fold (theoretical EF, 142-fold), the limits of detection (LODs, S/N=3) of the developed method for the target PAHs were found to be in the range of 0.05-2.94 ng/L. The developed method was successfully applied to the analysis of PAHs in Yangtze River and East Lake water samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Influence of coating quality on the service life of land-based gas turbine blades

    Energy Technology Data Exchange (ETDEWEB)

    Cheruvu, N.S. [Southwest Research Institute, San Antonio (United States)

    2007-06-15

    The land-based gas turbine blades operate at severe operating conditions: higher metal temperatures and stresses, and severe duty cycles. Metallic coatings with or without a top ceramic coating have been used to protect the turbine blades. The durability of the coating system is one of the prime life-limiting factors of modem gas turbine blades. The quality of the coating plays a critical role on the coating life. This paper discusses the failure mechanisms of the coatings and describes how the quality of the coating affects the service life of a gas turbine blade. A few case studies are presented in the paper. (orig.)

  1. Micro-thermal analysis of polyester coatings

    NARCIS (Netherlands)

    Fischer, H.R.

    2010-01-01

    The application and suitability of micro-thermal analysis to detect changes in the chemical and physical properties of coating due to ageing and especially photo-degradation is demonstrated using a model polyester coating based on neopentyl glycol isophthalic acid. The changes in chemical structure

  2. A wideband optical monitor for a planetary-rotation coating-system

    International Nuclear Information System (INIS)

    Campanelli, M.B.; Smith, D.J.

    1998-01-01

    A substrate-specific, through-planet, wideband optical coating monitor is being developed to increase production yield and the understanding of physical vapor deposition (PVD) coatings fabricated in the Optical Manufacturing Laboratory at the University of Rochester's Laboratory for Laser Energetics. In-situ wideband optical monitoring of planetary rotation systems allows direct monitoring of large, expensive substrates with complex layering schemes. The optical monitor discussed here is under development for coating several large (e.g., 80.7 x 41.7 x 9.0 cm) polarizers for the National Ignition Facility. Wideband optical monitoring of the production substrates is used in concert with an array of crystal monitors for process control, film parameter evaluation, and error detection with associated design reoptimization. The geometry of a planetary rotation system, which produces good uniformity across large substrates, makes optical monitoring more difficult. Triggering and timing techniques for data acquisition become key to the process because the optical coating is available only intermittently for monitoring. Failure to properly consider the effects of the system dynamics during data retrieval and processing may result in significant decreases in the spectral data's reliability. Improved data accuracy allows better determination of film thicknesses, indices, and inhomogeneities and enables in-situ error detection for design reoptimization

  3. Multilayer composition coatings for cutting tools: formation and performance properties

    Science.gov (United States)

    Tabakov, Vladimir P.; Vereschaka, Anatoly S.; Vereschaka, Alexey A.

    2018-03-01

    The paper considers the concept of a multi-layer architecture of the coating in which each layer has a predetermined functionality. Latest generation of coatings with multi-layered architecture for cutting tools secure a dual nature of the coating, in which coatings should not only improve the mechanical and physical characteristics of the cutting tool material, but also reduce the thermo-mechanical effect on the cutting tool determining wear intensity. Here are presented the results of the development of combined methods of forming multi-layer coatings with improved properties. Combined method of forming coatings using a pulsed laser allowed reducing excessively high levels of compressive residual stress and increasing micro hardness of the multilayered coatings. The results in testing coated HSS tools showed that the use of additional pulse of laser processing increases tool life up to 3 times. Using filtered cathodic vacuum arc deposition for the generation of multilayer coatings based on TiAlN compound has increased the wear-resistance of carbide tools by 2 fold compared with tool life of cutting tool with commercial TiN coatings. The aim of this study was to develop an innovative methodological approach to the deposition of multilayer coatings for cutting tools with functional architectural selection, properties and parameters of the coating based on sound knowledge of coating failure in machining process.

  4. Heart failure - tests

    Science.gov (United States)

    CHF - tests; Congestive heart failure - tests; Cardiomyopathy - tests; HF - tests ... the best test to: Identify which type of heart failure (systolic, diastolic, valvular) Monitor your heart failure and ...

  5. Thermal shock behavior of platinum aluminide bond coat/electron beam-physical vapor deposited thermal barrier coatings

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhenhua, E-mail: zhxuciac@163.com [Beijing Institute of Aeronautical Materials, Department 5, P.O. Box 81-5, Beijing 100095 (China); Dai, Jianwei [Beijing Institute of Aeronautical Materials, Department 5, P.O. Box 81-5, Beijing 100095 (China); Niu, Jing [Shenyang Liming Aero-engine (Group) Corporation Ltd., Institute of Metallurgical Technology, Technical Center, Shengyang 110043 (China); Li, Na; Huang, Guanghong; He, Limin [Beijing Institute of Aeronautical Materials, Department 5, P.O. Box 81-5, Beijing 100095 (China)

    2014-12-25

    Highlights: • TBCs of (Ni, Pt)Al bond coat with grit blasting process and YSZ ceramic coating. • Grain boundary ridges are the sites for spallation damage initiation in TBCs. • Ridges removed, cavities formation appeared and the damage initiation deteriorated. • Damage initiation and progression at interface lead to a buckling failure. - Abstract: Thermal barrier coating systems (TBCs) including of chemical vapor deposited (Ni, Pt)Al bond coat with grit blasting process and electron beam physical vapor deposited Y{sub 2}O{sub 3}-stabilized-ZrO{sub 2} (YSZ) ceramic coating were investigated. The phase structures, surface and cross-sectional morphologies, thermal shock behaviors and residual stresses of the coatings were studied in detail. Grain boundary ridges still remain on the surface of bond coat prior to the deposition of the ceramic coating, which are shown to be the major sites for spallation damage initiation in TBCs. When these ridges are mostly removed, they appear some of cavities formation and then the damage initiation mode is deteriorated. Damage initiation and progression occurs at the bond coat to thermally grown oxide (TGO) interface leading to a buckling failure behavior. A buckle failure once started may be arrested when it runs into a region of high bond coat to TGO interface toughness. Thus, complete failure requires further loss in toughness of the bond coat to TGO interface during cooling. The suppressed cavities formation, the removed ridges at the grain boundaries, the relative high TGO to bond coat interface toughness, the uniform growth behavior of TGO thickening and the lower of the residual stress are the primary factors for prolonging the lifetime of TBCs.

  6. Competitive binding of polyethyleneimine-coated gold nanoparticles to enzymes and bacteria: a key mechanism for low-level colorimetric detection of gram-positive and gram-negative bacteria

    International Nuclear Information System (INIS)

    Thiramanas, Raweewan; Laocharoensuk, Rawiwan

    2016-01-01

    The article describes a simple and rapid method for colorimetric detection of bacteria. It is based on competitive binding of positively charged polyethyleneimine-coated gold nanoparticles (PEI-AuNPs) to negatively charged enzymes and bacteria. The PEI-AuNPs are electrostatically attracted by both the bacterial surface and the enzyme β-galactosidase (β-Gal). Binding to the latter results in the inhibition of enzyme activity. However, in the presence of a large number of bacteria, the PEI-AuNPs preferentially bind to bacteria. Hence, the enzyme will not be inhibited and its activity can be colorimetrically determined via hydrolysis of the chromogenic substrate chlorophenol red β-D-galactopyranoside (CPRG). The detection limit of this assay is as low as 10 cfu·mL −1 , and the linear range extends from 10 6 to 10 8 cfu·mL −1 . The assay is applicable to both Gram-negative (such as enterotoxigenic Escherichia coli; ETEC) and Gram-positive (Staphylococcus aureus; S. aureus) bacteria. Results are obtained within 10 min using an optical reader, and within 2–3 h by bare-eye detection. The method was applied to the identification of ETEC contamination at a level of 10 cfu·mL −1 in spiked drinking water. Given its low detection limit and rapidity (sample preconcentration is not required), this method holds great promise for on-site detection of total bacterial contamination. (author)

  7. Coating materials

    International Nuclear Information System (INIS)

    Ozeki, Takao; Kimura, Tadashi; Kobayashi, Juichi; Maeda, Yutaka; Nakamoto, Hideo.

    1969-01-01

    A non-solvent type coating material composition having properties as good as thermosetting acrylic or amino alkid resins is provided by employing active energy irradiation, particularly electron beams, using a radically polymerizable low molecular compound (A) (hereafter called an oligomer) containing at least two vinyl radicals in one molecule. This oligomer is produced by reacting an epoxy-containing vinyl monomer with alpha-, beta-ethylene unsaturated carboxylic acids or their anhydrides. The composition (I) contains 10% - 100% of this oligomer. In embodiments, an oligomer having a fiberous trivinyl construction is produced by reacting 180 parts by weight of glycidyl methacrylate ester with 130 parts of itaconic acid in the presence of a polymerization-inhibitor and an addition reaction catalyst at 90 0 C for 6 hours. In practice, the coating material compositions (1), consist of the whole oligomer [I-1]; (2), consist of 10-90% of (A) component and 90%-10% of vinyl monomers containing at least 30% (meth) acrylic monomer [I-2]; (3), 10%-90% of component (A) and 90%-10% of other monomers containing at least two vinyl radicals [I-3]; (4), a mixture of (I-2) and (I-3), [I-4]; and (5), consist of 50% or less unsaturated polyester of 500-5,000 molecular weight range or drying oil, or alkyd resin of 500-5,000 molecular weight range modified by drying oil, [I-5]. As a catalyst a tertiary amino vinyl compound is preferred. Five examples are given. (Iwakiri, K.)

  8. Cathodic delamination of seawater-immersed anticorrosive coatings: Mapping of parameters affecting the rate

    DEFF Research Database (Denmark)

    Sørensen, Per Aggerholm; Dam-Johansen, Kim; Weinell, C. E.

    2010-01-01

    Abstract: Cathodic delamination is one of the major modes of failure for organic coatings immersed in seawater and refers to the weakening or loss of adhesion between the coating and the substrate. The diminished adhesion is the result of electrochemical reactions occurring at the coating...

  9. Investigation of metallurgical coatings for automotive applications

    Science.gov (United States)

    Su, Jun Feng

    Metallurgical coatings have been widely used in the automotive industry from component machining, engine daily running to body decoration due to their high hardness, wear resistance, corrosion resistance and low friction coefficient. With high demands in energy saving, weight reduction and limiting environmental impact, the use of new materials such as light Aluminum/magnesium alloys with high strength-weight ratio for engine block and advanced high-strength steel (AHSS) with better performance in crash energy management for die stamping, are increasing. However, challenges are emerging when these new materials are applied such as the wear of the relative soft light alloys and machining tools for hard AHSS. The protective metallurgical coatings are the best option to profit from these new materials' advantages without altering largely in mass production equipments, machinery, tools and human labor. In this dissertation, a plasma electrolytic oxidation (PEO) coating processing on aluminum alloys was introduced in engine cylinder bores to resist wear and corrosion. The tribological behavior of the PEO coatings under boundary and starve lubrication conditions was studied experimentally and numerically for the first time. Experimental results of the PEO coating demonstrated prominent wear resistance and low friction, taking into account the extreme working conditions. The numerical elastohydrodynamic lubrication (EHL) and asperity contact based tribological study also showed a promising approach on designing low friction and high wear resistant PEO coatings. Other than the fabrication of the new coatings, a novel coating evaluation methodology, namely, inclined impact sliding tester was presented in the second part of this dissertation. This methodology has been developed and applied in testing and analyzing physical vapor deposition (PVD)/ chemical vapor deposition (CVD)/PEO coatings. Failure mechanisms of these common metallurgical hard coatings were systematically

  10. Microencapsulation of Corrosion Indicators for Smart Coatings

    Science.gov (United States)

    Li, Wenyan; Buhrow, Jerry W.; Jolley, Scott T.; Calle, Luz M.; Hanna,Joshua S.; Rawlins, James W.

    2011-01-01

    A multifunctional smart coating for the autonomous detection, indication, and control of corrosion is been developed based on microencapsulation technology. This paper summarizes the development, optimization, and testing of microcapsules specifically designed for early detection and indication of corrosion when incorporated into a smart coating. Results from experiments designed to test the ability of the microcapsules to detect and indicate corrosion, when blended into several paint systems, show that these experimental coatings generate a color change, indicative of spot specific corrosion events, that can be observed with the naked eye within hours rather than the hundreds of hours or months typical of the standard accelerated corrosion test protocols.. Key words: smart coating, corrosion detection, microencapsulation, microcapsule, pH-sensitive microcapsule, corrosion indicator, corrosion sensing paint

  11. Design and Characterization of High-strength Bond Coats for Improved Thermal Barrier Coating Durability

    Science.gov (United States)

    Jorgensen, David John

    High pressure turbine blades in gas turbine engines rely on thermal barrier coating (TBC) systems for protection from the harsh combustion environment. These coating systems consist of a ceramic topcoat for thermal protection, a thermally grown oxide (TGO) for oxidation passivation, and an intermetallic bond coat to provide compatibility between the substrate and ceramic over-layers while supplying aluminum to sustain Al2O 3 scale growth. As turbine engines are pushed to higher operating temperatures in pursuit of better thermal efficiency, the strength of industry-standard bond coats limits the lifetime of these coating systems. Bond coat creep deformation during thermal cycling leads to a failure mechanism termed rumpling. The interlayer thermal expansion differences, combined with TGO-imposed growth stresses, lead to the development of periodic undulations in the bond coat. The ceramic topcoat has low out-of-plane compliance and thus detaches and spalls from the substrate, resulting in a loss of thermal protection and subsequent degradation of mechanical properties. New creep resistant Ni3Al bond coats were designed with improved high-temperature strength to inhibit this type of premature failure at elevated temperatures. These coatings resist rumpling deformation while maintaining compatibility with the other layers in the system. Characterization methods are developed to quantify rumpling and assess the TGO-bond coat interface toughness of experimental systems. Cyclic oxidation experiments at 1163 °C show that the Ni3Al bond coats do not experience rumpling but have faster oxide growth rates and are quicker to spall TGO than the (Pt,Ni)Al benchmark. However, the Ni 3Al coatings outperformed the benchmark by over threefold in TBC system life due to a higher resistance to rumpling (mechanical degradation) while maintaining adequate oxidation passivation. The Ni3Al coatings eventually grow spinel NiAl2O4 on top of the protective Al2O3 layer, which leads to the

  12. Heart failure - home monitoring

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000113.htm Heart failure - home monitoring To use the sharing features on ... your high blood pressure Fast food tips Heart failure - discharge Heart failure - fluids and diuretics Heart failure - what to ...

  13. Coatings and Corrosion Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose: The mission of the Coatings and Corrosion Laboratory is to develop and analyze the effectiveness of innovative coatings test procedures while evaluating the...

  14. Corrosion issues of powder coated AA6060 aluminium profiles

    DEFF Research Database (Denmark)

    Din, Rameez Ud; Valgarðsson, Smári; Jellesen, Morten Stendahl

    2015-01-01

    In this study detailed microstructural investigation of the reason for unexpected corrosion of powder coated aluminium alloy AA6060 windows profiles has been performed. The results from this study reveals that the failure of the window profiles was originated from the surface defects present...... on the extruded AA6060 aluminium profile after metallurgical process prior to powder coating. Surface defects are produced due to intermetallic particles in the alloy, which disturb the flow during the extrusion process. The corrosion mechanism leading to the failure of the powder coated AA6060 aluminium profiles...

  15. FEM simulation of TBC failure in a model system

    Energy Technology Data Exchange (ETDEWEB)

    Seiler, P; Baeker, M; Roesier, J [Institut fuer Werkstoffe (IfW), Technische Universitaet Braunschweig (Germany); Beck, T; Schweda, M, E-mail: p.seiler@tu-bs.d [Institut fuer Energieforschung/ Werkstoffstruktur und -Eigenschaften (IEF 2), Forschungszentrum Juelich (Germany)

    2010-07-01

    In order to study the behavior of the complex failure mechanisms in thermal barrier coatings on turbine blades, a simplified model system is used to reduce the number of system parameters. The artificial system consists of a bond-coat material (fast creeping Fecralloy or slow creeping MA956) as the substrate with a Y{sub 2}O{sub 3} partially stabilized plasma sprayed zircon oxide TBC on top and a TGO between the two layers. A 2-dimensional FEM simulation was developed to calculate the growth stress inside the simplified coating system. The simulation permits the study of failure mechanisms by identifying compression and tension areas which are established by the growth of the oxide layer. This provides an insight into the possible crack paths in the coating and it allows to draw conclusions for optimizing real thermal barrier coating systems.

  16. Retrospective Identification of Herpes Simplex 2 Virus-Associated Acute Liver Failure in an Immunocompetent Patient Detected Using Whole Transcriptome Shotgun Sequencing.

    Science.gov (United States)

    Ono, Atsushi; Hayes, C Nelson; Akamatsu, Sakura; Imamura, Michio; Aikata, Hiroshi; Chayama, Kazuaki

    2017-01-01

    Acute liver failure (ALF) is a severe condition in which liver function rapidly deteriorates in individuals without prior history of liver disease. While most cases result from acetaminophen overdose or viral hepatitis, in up to a third of patients, no clear cause can be identified. Liver transplantation has greatly reduced mortality among these patients, but 40% of patients recover without liver transplantation. Therefore, there is an urgent need for rapid determination of the etiology of acute liver failure. In this case report, we present a case of herpes simplex 2 virus- (HSV-) associated ALF in an immunocompetent patient. The patient recovered without LT, but the presence of HSV was not suspected at the time, precluding more effective treatment with acyclovir. To determine the etiology, stored blood samples were analyzed using whole transcriptome shotgun sequencing followed by mapping to a panel of viral reference sequences. The presence of HSV-DNA in blood samples at the time of admission was confirmed using real-time polymerase chain reaction, and, at the time of discharge, HSV-DNA levels had decreased by a factor of 10 6 . Conclusions. In ALF cases of undetermined etiology, uncommon causes should be considered, especially those for which an effective treatment is available.

  17. Retrospective Identification of Herpes Simplex 2 Virus-Associated Acute Liver Failure in an Immunocompetent Patient Detected Using Whole Transcriptome Shotgun Sequencing

    Directory of Open Access Journals (Sweden)

    Atsushi Ono

    2017-01-01

    Full Text Available Acute liver failure (ALF is a severe condition in which liver function rapidly deteriorates in individuals without prior history of liver disease. While most cases result from acetaminophen overdose or viral hepatitis, in up to a third of patients, no clear cause can be identified. Liver transplantation has greatly reduced mortality among these patients, but 40% of patients recover without liver transplantation. Therefore, there is an urgent need for rapid determination of the etiology of acute liver failure. In this case report, we present a case of herpes simplex 2 virus- (HSV- associated ALF in an immunocompetent patient. The patient recovered without LT, but the presence of HSV was not suspected at the time, precluding more effective treatment with acyclovir. To determine the etiology, stored blood samples were analyzed using whole transcriptome shotgun sequencing followed by mapping to a panel of viral reference sequences. The presence of HSV-DNA in blood samples at the time of admission was confirmed using real-time polymerase chain reaction, and, at the time of discharge, HSV-DNA levels had decreased by a factor of 106. Conclusions. In ALF cases of undetermined etiology, uncommon causes should be considered, especially those for which an effective treatment is available.

  18. Clinically relevant diagnostic research in primary care: the example of B-type natriuretic peptides in the detection of heart failure.

    Science.gov (United States)

    Kelder, Johannes C; Rutten, Frans H; Hoes, Arno W

    2009-02-01

    With the emergence of novel diagnostic tests, e.g. point-of-care tests, clinically relevant empirical evidence is needed to assess whether such a test should be used in daily practice. With the example of the value of B-type natriuretic peptides (BNP) in the diagnostic assessment of suspected heart failure, we will discuss the major methodological issues crucial in diagnostic research; most notably the choice of the study population and the data analysis with a multivariable approach. BNP have been studied extensively in the emergency care setting, and also several studies in the primary care are available. The usefulness of this test when applied in combination with other readily available tests is still not adequately addressed in the relevant patient domain, i.e. those who are clinically suspected of heart failure by their GP. Future diagnostic research in primary care should be targeted much more at answering the clinically relevant question 'Is it useful to add this (new) test to the other tests I usually perform, including history taking and physical examination, in patients I suspect of having a certain disease'.

  19. Thermal stability of double-ceramic-layer thermal barrier coatings with various coating thickness

    International Nuclear Information System (INIS)

    Dai Hui; Zhong Xinghua; Li Jiayan; Zhang Yanfei; Meng Jian; Cao Xueqiang

    2006-01-01

    Double-ceramic-layer (DCL) coatings with various thickness ratios composed of YSZ (6-8 wt.% Y 2 O 3 + ZrO 2 ) and lanthanum zirconate (LZ, La 2 Zr 2 O 7 ) were produced by the atmospheric plasma spraying. Chemical stability of LZ in contact with YSZ in DCL coatings was investigated by calcining powder blends at different temperatures. No obvious reaction was observed when the calcination temperature was lower than 1250 deg. C, implying that LZ and YSZ had good chemical applicability for producing DCL coating. The thermal cycling test indicate that the cycling lives of the DCL coatings are strongly dependent on the thickness ratio of LZ and YSZ, and the coatings with YSZ thickness between 150 and 200 μm have even longer lives than the single-layer YSZ coating. When the YSZ layer is thinner than 100 μm, the DCL coatings failed in the LZ layer close to the interface of YSZ layer and LZ layer. For the coatings with the YSZ thickness above 150 μm, the failure mainly occurs at the interface of the YSZ layer and the bond coat

  20. High temperature oxidation behavior of hafnium modified NiAl bond coat in EB-PVD thermal barrier coating system

    Energy Technology Data Exchange (ETDEWEB)

    Guo Hongbo; Sun Lidong; Li Hefei [Department of Material Science and Engineering, Beijing University of Aeronautics and Astronautics, No.37 Xueyuan Road, Beijing 100083 (China); Gong Shengkai [Department of Material Science and Engineering, Beijing University of Aeronautics and Astronautics, No.37 Xueyuan Road, Beijing 100083 (China)], E-mail: gongsk@buaa.edu.cn

    2008-06-30

    NiAl coatings doped with 0.5 at.% and 1.5 at.% Hf were produced by co-evaporation of NiAl and Hf ingots by electron beam physical vapor deposition (EB-PVD), respectively. The addition of 0.5 at.% Hf significantly improved the cyclic oxidation resistance of the NiAl coating. The TGO layer in the 1.5 at.% Hf doped NiAl coating is straight; while that in the 0.5 at.% Hf doped coating became undulated after thermal cycling. The doped NiAl thermal barrier coatings (TBCs) revealed improved thermal cycling lifetimes at 1423 K, compared to the undoped TBC. Failure of the 0.5 at.% Hf doped TBC occurred by cracking at the interface between YSZ topcoat and bond coat, while the 1.5 at.% Hf doped TBC cracked at the interface between bond coat and substrate.

  1. Graphene Coatings

    DEFF Research Database (Denmark)

    Stoot, Adam Carsten; Camilli, Luca; Bøggild, Peter

    2014-01-01

    Owing to its remarkable electrical and mechanical properties, graphene has been attracting tremendous interest in materials science. In particular, its chemical stability and impermeability make it a promising protective membrane. However, recent investigations reveal that single layer graphene...... cannot be used as a barrier in the long run, due to galvanic corrosion phenomena arising when oxygen or water penetrate through graphene cracks or domain boundaries. Here, we overcome this issue by using a multilayered (ML) graphene coating. Our lab- as well as industrial-scale tests demonstrate that ML...... graphene can effectively protect Ni in harsh environments, even after long term exposure. This is made possible by the presence of a high number of graphene layers, which can efficiently mask the cracks and domain boundaries defects found in individual layers of graphene. Our findings thus show...

  2. Coating materials

    International Nuclear Information System (INIS)

    Ozeki, Takao; Kimura, Tadashi; Kobayashi, Juichi; Maeda, Yutaka; Nakamoto, Hideo.

    1969-01-01

    A non-solvent type coating material composition is provided which can be hardened by irradiation with active energy, particularly electron beams, using a composition which contains 10%-100% of a radically polymerizable low molecular compound (A), (hereafter called an oligomer), having at least two vinyl radicals in one molecule. These compositions have a high degree of polymerization and characteristics equivalent to thermosetting acrylic or amino alkyd resin. The oligomer (A) is produced by reacting an epoxy-containing vinyl monomer with saturated polycarboxylic acids or anhydrides. In one embodiment, 146 parts by weight of adipic acid and 280 parts of glycidyl methacrylate ester undergo addition reaction in the presence of a polymerization-inhibitor and a catalyst at 90 0 C for 6 hours to produce an oligomer having a fiberous divinyl construction. The coating composition utilizes this oligomer in the forms of (I-1), a whole oligomer; (I-2), 0%-90% of this oligomer and 90%-10% of a vinyl monomer containing at least 30% of (meth) acrylic monomer; (I-3), 10%-90% of such oligomer and 90%-10% of other monomers containing at least two vinyl radicals in one molecule; (I-4), a mixture of (I-2) and (I-3) in proportion of 1/9 to 9/1, and (I-5), above four compositions each containing 50% or less unsaturated polyester or drying oil having 500-5,000 molecules or a drying oil-modified alkyd resin having 500-5,000 molecules. Four examples are given. (Iwakiri, K.)

  3. Titania and Zinc Oxide Nanoparticles: Coating with Polydopamine and Encapsulation within Lecithin Liposomes—Water Treatment Analysis by Gel Filtration Chromatography with Fluorescence Detection

    Directory of Open Access Journals (Sweden)

    Xuhao Zhao

    2018-02-01

    Full Text Available The interplay of metal oxide nanoparticles, environmental pollution, and health risks is key to all industrial and drinking water treatment processes. In this work we present a study using gel filtration chromatography for the analytical investigation of metal oxide nanoparticles in water, their coating with polydopamine, and their encapsulation within lecithin liposomes. Polydopamine prevents TiO2 and ZnO nanoparticles from aggregation during chromatographic separation. Lecithin forms liposomes that encapsulate the nanoparticles and carry them through the gel filtration column, producing an increase of peak area for quantitative analysis without any change in retention time to affect qualitative identification. To the best of our knowledge, this is the first report that demonstrates the potential application of lecithin liposomes for cleaning up metal oxide nanoparticles in water treatment. Encapsulation of graphene quantum dots by liposomes would allow for monitoring of nanoparticle-loaded liposomes to ensure their complete removal by membrane ultrafiltration from treated water.

  4. Mitochondrial markers predict recurrence, metastasis and tamoxifen-resistance in breast cancer patients: Early detection of treatment failure with companion diagnostics.

    Science.gov (United States)

    Sotgia, Federica; Fiorillo, Marco; Lisanti, Michael P

    2017-09-15

    Here, we used a data-mining and informatics approach to discover new biomarkers of resistance to hormonal therapy in breast cancer. More specifically, we investigated whether nuclear-encoded genes associated with mitochondrial biogenesis can be used to predict tumor recurrence, distant metastasis and treatment failure in high-risk breast cancer patients. Overall, this strategy allowed us to directly provide in silico validation of the prognostic value of these mitochondrial components in large and clinically relevant patient populations, with >15 years of follow-up data. For this purpose, we employed a group of 145 ER(+) luminal A breast cancer patients, with lymph-node (LN) metastasis at diagnosis, that were treated with tamoxifen, but not any chemotherapy agents. Using this approach, we identified >60 new individual mitochondrial biomarkers that predicted treatment failure and tumor recurrence, with hazard-ratios (HR) of up to 4.17 ( p =2.2e-07). These include mitochondrial chaperones (HSPD1, HSPA9), membrane proteins (VDAC2, TOMM70A) and anti-oxidants (SOD2), as well as 18 different mitochondrial ribosomal proteins (MRPs) and >20 distinct components of the OXPHOS complexes. In addition, we combined 4 mitochondrial proteins (HSPD1, UQCRB, MRPL15, COX17), to generate a compact mitochondrial gene signature, associated with a HR of 5.34 ( p =1e-09). This signature also successfully predicted distant metastasis and was effective in larger groups of ER(+) ( N =2,447), basal ( N =540) and HER2(+) ( N =193) breast cancers. It was also effective in all breast cancers ( N =3,180), if considered together as a single group. Based on this analysis, we conclude that mitochondrial biogenesis should be considered as a new therapeutic target for overcoming tumor recurrence, distant metastasis and treatment failure in patients with breast cancer. In summary, we identified individual mitochondrial biomarkers and 2 compact mitochondrial gene signatures that can be used to predict

  5. Zirconia coated stir bar sorptive extraction combined with large volume sample stacking capillary electrophoresis-indirect ultraviolet detection for the determination of chemical warfare agent degradation products in water samples.

    Science.gov (United States)

    Li, Pingjing; Hu, Bin; Li, Xiaoyong

    2012-07-20

    In this study, a sensitive, selective and reliable analytical method by combining zirconia (ZrO₂) coated stir bar sorptive extraction (SBSE) with large volume sample stacking capillary electrophoresis-indirect ultraviolet (LVSS-CE/indirect UV) was developed for the direct analysis of chemical warfare agent degradation products of alkyl alkylphosphonic acids (AAPAs) (including ethyl methylphosphonic acid (EMPA) and pinacolyl methylphosphonate (PMPA)) and methylphosphonic acid (MPA) in environmental waters. ZrO₂ coated stir bar was prepared by adhering nanometer-sized ZrO₂ particles onto the surface of stir bar with commercial PDMS sol as adhesion agent. Due to the high affinity of ZrO₂ to the electronegative phosphonate group, ZrO₂ coated stir bars could selectively extract the strongly polar AAPAs and MPA. After systematically optimizing the extraction conditions of ZrO₂-SBSE, the analytical performance of ZrO₂-SBSE-CE/indirect UV and ZrO₂-SBSE-LVSS-CE/indirect UV was assessed. The limits of detection (LODs, at a signal-to-noise ratio of 3) obtained by ZrO₂-SBSE-CE/indirect UV were 13.4-15.9 μg/L for PMPA, EMPA and MPA. The relative standard deviations (RSDs, n=7, c=200 μg/L) of the corrected peak area for the target analytes were in the range of 6.4-8.8%. Enhancement factors (EFs) in terms of LODs were found to be from 112- to 145-fold. By combining ZrO₂ coating SBSE with LVSS as a dual preconcentration strategy, the EFs were magnified up to 1583-fold, and the LODs of ZrO₂-SBSE-LVSS-CE/indirect UV were 1.4, 1.2 and 3.1 μg/L for PMPA, EMPA, and MPA, respectively. The RSDs (n=7, c=20 μg/L) were found to be in the range of 9.0-11.8%. The developed ZrO₂-SBSE-LVSS-CE/indirect UV method has been successfully applied to the analysis of PMPA, EMPA, and MPA in different environmental water samples, and the recoveries for the spiked water samples were found to be in the range of 93.8-105.3%. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. A Fast and Cost-Effective Detection of Melamine by Surface Enhanced Raman Spectroscopy Using a Novel Hydrogen Bonding-Assisted Supramolecular Matrix and Gold-Coated Magnetic Nanoparticles

    Directory of Open Access Journals (Sweden)

    Jing Neng

    2017-05-01

    Full Text Available A fast and cost-effective melamine detection approach has been developed based on surface enhanced Raman spectroscopy (SERS using a novel hydrogen bonding-assisted supramolecular matrix. The detection utilizes Fe3O4/Au magnetic nanoparticles coated with 5-aminoorotic acid (AOA as a SERS active substrate (Fe3O4/Au–AOA, and Rhodamine B (RhB conjugated AOA as a Raman reporter (AOA–RhB. Upon mixing the reagents with melamine, a supramolecular complex [Fe3O4/Au–AOA•••melamine•••AOA–RhB] was formed due to the strong multiple hydrogen bonding interactions between AOA and melamine. The complex was separated and concentrated to a pellet by an external magnet and used as a supramolecular matrix for the melamine detection. Laser excitation of the complex pellet produced a strong SERS signal diagnostic for RhB. The logarithmic intensity of the characteristic RhB peaks was found to be proportional to the concentration of melamine with a limit of detection of 2.5 µg/mL and a detection linearity range of 2.5~15.0 µg/mL in milk. As Fe3O4 nanoparticles and AOA are thousands of times less expensive than the monoclonal antibody used in a traditional sandwich immunoassay, the current assay drastically cut down the cost of melamine detection. The current approach affords promise as a biosensor platform that cuts down sample pre-treatment steps and measurement expense.

  7. Thermal Shock Resistance of Stabilized Zirconia/Metal Coat on Polymer Matrix Composites by Thermal Spraying Process

    Science.gov (United States)

    Zhu, Ling; Huang, Wenzhi; Cheng, Haifeng; Cao, Xueqiang

    2014-12-01

    Stabilized zirconia/metal coating systems were deposited on the polymer matrix composites by a combined thermal spray process. Effects of the thicknesses of metal layers and ceramic layer on thermal shock resistance of the coating systems were investigated. According to the results of thermal shock lifetime, the coating system consisting of 20 μm Zn and 125 μm 8YSZ exhibited the best thermal shock resistance. Based on microstructure evolution, failure modes and failure mechanism of the coating systems were proposed. The main failure modes were the formation of vertical cracks and delamination in the outlayer of substrate, and the appearance of coating spallation. The residual stress, thermal stress and oxidation of substrate near the substrate/metal layer interface were responsible for coating failure, while the oxidation of substrate near the substrate/coating interface was the dominant one.

  8. Testing of low Z coated limiters in tokamak fusion devices

    International Nuclear Information System (INIS)

    Whitely, J.B.; Mullendore, A.W.; Langley, R.A.

    1980-01-01

    Extensive testing on a laboratory scale has been used to select those coatings most suitable for this environment. From this testing which included pulsed electron beam heating, low energy ion bombardment and arcing, chemical vapor deposited coating of TiB 2 and TiC on Poco graphite substrates have been selected and tested as limiters in ISX. Both limiter materials gave clean, stable, reproducible tokamak discharges the first day of operation. After one weeks exposure, the TiC limiter showed only superficial damage with no coating failure. The TiB 2 limiter had some small areas of coating failure. TiC coated graphite limiters have also been briefly tested in the tokamaks Alcator and PDX with favorable results

  9. Electrocurtain coating process for coating solar mirrors

    Science.gov (United States)

    Kabagambe, Benjamin; Boyd, Donald W.; Buchanan, Michael J.; Kelly, Patrick; Kutilek, Luke A.; McCamy, James W.; McPheron, Douglas A.; Orosz, Gary R.; Limbacher, Raymond D.

    2013-10-15

    An electrically conductive protective coating or film is provided over the surface of a reflective coating of a solar mirror by flowing or directing a cation containing liquid and an anion containing liquid onto the conductive surface. The cation and the anion containing liquids are spaced from, and preferably out of contact with one another on the surface of the reflective coating as an electric current is moved through the anion containing liquid, the conductive surface between the liquids and the cation containing liquid to coat the conductive surface with the electrically conductive coating.

  10. Steam generator tube failures

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service

  11. Low Temperature Powder Coating

    Science.gov (United States)

    2011-02-09

    of volatile organic compounds (VOCs) and hazardous air pollutants (HAPs) • Legacy primers contain hexavalent chrome • Conventional powder coatings...coatings both in laboratory and field service evaluations • LTCPC allows environmental cost reductions through VOC/HAP elimination and hexavalent ... chrome reduction. • The LTCPC process greatly shortens the coating operation (LTCPC cures much more rapidly then conventional wet coatings) resulting in

  12. Irradiation behaviors of coated fuel particles, (4)

    International Nuclear Information System (INIS)

    Fukuda, Kousaku; Kashimura, Satoru; Ogawa, Toru; Ikawa, Katsuichi; Iwamoto, Kazumi; Ishimoto, Kiyoshi

    1981-09-01

    Loose coated fuel particles prepared in confirmity to a preliminary design for the multi-purpose VHTR in fiscal 1972 - 1974 were irradiated by 73F - 12A capsule in JMTR. Main purpose for this irradiation experiment was to examine irradiation stability of the candidate TRISO coated fuel particles for the VHTR. Also the coated particles possessing low-density kernel (90%TD), highly anisotropic OLTI-PyC and ZrC coating layer were loaded with the candidate particles in this capsule. The coated particles were irradiated up to 1.5 x 10 21 n/cm 2 of fast neutron fluence (E > 0.18 MeV) and 3.2% FIMA of burnup. In the post irradiation examination it was observed that among three kinds of TRISO particles exposed to irradiation corresponding to the normal operating condition of the VHTR ones possessing poor characteristics of the coating layers did not show a good stability. The particles irradiated under abnormally high temperature condition (> 1800 0 C) revealed 6.7% of max. EOL failure fraction (95% confidence limit). Most of these particles were failed by the ameoba effect. Furthermore, among four kinds of the TRISO particles exposed to irradiation corresponding to the transient condition of the VHTR (--1500 0 C) the two showed a good stability, while the particles possessing highly anisotropic OLTI-PyC or poorly characteristic coating layers were not so good. (author)

  13. Palliative Care in Heart Failure

    Directory of Open Access Journals (Sweden)

    Hatice Mert

    2012-04-01

    Full Text Available Heart failure is an important health problem since its incidence and prevalence is increasing year by year. Since symptom burden and mortality are high in heart failure, supportive and palliative care should be provided. However, very few patients are referred to palliative care services. In comparison with cancer patients, it is difficult to identify end of life care for patients with heart failure, because these patients are hospitalized when the signs of acute decompensation appear, and their symptoms decrease and functional status improve before they are discharged. Therefore, palliative care, which is a holistic approach aiming to improve patients’ quality of life, to detect and treat the attacks of the disease before they become severe, and to deal with patients’ physical, psychological, social, and mental health altogether during their care, should be integrated into heart failure patients’ care. [TAF Prev Med Bull 2012; 11(2.000: 217-222

  14. An evaluation of the use of new Doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model

    Science.gov (United States)

    Tabata, Tomotsugu; Cardon, Lisa A.; Armstrong, Guy P.; Fukamach, Kiyotaka; Takagaki, Masami; Ochiai, Yoshie; McCarthy, Patrick M.; Thomas, James D.

    2003-01-01

    BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

  15. Hand-held optical sensor using denatured antibody coated electro-active polymer for ultra-trace detection of copper in blood serum and environmental samples.

    Science.gov (United States)

    Chandra, Sutapa; Dhawangale, Arvind; Mukherji, Soumyo

    2018-07-01

    An optimum copper concentration in environment is highly desired for all forms of life. We have developed an ultrasensitive copper sensor which functions from femto to micro molar concentration accurately (R 2 = 0.98). The sensor is based on denatured antibody immunoglobulin G (IgG), immobilized on polyaniline (PAni) which in turn is the coating on the core of an optical fiber. The sensing relies on changes in evanescent wave absorbance in the presence of the analyte. The sensor showed excellent selectivity towards Cu (II) ions over all other metal ions. The sensor was tested with lake and marine water samples to determine unknown concentrations of copper ions and the recovery results were within 90-115%, indicating reasonable accuracy. We further integrated the fiber-optic sensor with a miniaturized hand-held instrumentation platform to develop an accurate and field deployable device which can broadly be applicable to determine Cu (II) concentration in a wide range of systems - natural water bodies, soil as well as blood serum. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Use of green coating (cork) in solid-phase microextraction for the determination of organochlorine pesticides in water by gas chromatography-electron capture detection.

    Science.gov (United States)

    Neves Dias, Adriana; Simão, Vanessa; Merib, Josias; Carasek, Eduardo

    2015-03-01

    A novel method for the determination of organochlorine pesticides in water samples with extraction using cork fiber and analysis by gas chromatography with electron capture detector was developed. Also, the procedure to extract these pesticides with DVB/Car/PDMS fiber was optimized. The optimization of the variables involved in the extraction of organochlorine pesticides using the aforementioned fibers was carried out by multivariate design. The optimum extraction conditions were sample temperature 75 °C, extraction time 60 min and sodium chloride concentration 10% for the cork fiber and sample temperature 50 °C and extraction time 60 min (without salt) for the DVB/Car/PDMS fiber. The quantification limits for the two fibers varied between 1.0 and 10.0 ng L(-1). The linear correlation coefficients were >0.98 for both fibers. The method applied with the use of the cork fiber provided recovery values between 60.3 and 112.7 and RSD≤25.5 (n=3). The extraction efficiency values for the cork and DVB/Car/PDMS fibers were similar. The results show that cork is a promising alternative as a coating for SPME. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. On the interfacial degradation mechanisms of thermal barrier coating systems: Effects of bond coat composition

    Energy Technology Data Exchange (ETDEWEB)

    Wu, R.T., E-mail: WU.Rudder@nims.go.jp [International Center for Young Scientists, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba City, Ibaraki (Japan); Wang, X.; Atkinson, A. [Department of Materials, Imperial College London, Prince Consort Road, London SW7 2BP (United Kingdom)

    2010-10-15

    Thermal barrier coating (TBC) systems based on an electron beam physical vapour deposited, yttria-stabilized zirconia (YSZ) top coat and a substrate material of CMSX-4 superalloy were identically prepared to systematically study the behaviour of different bond coats. The three bond coat systems investigated included two {beta}-structured Pt-Al types and a {gamma}-{gamma}' type produced by Pt diffusion without aluminizing. Progressive evolution of stress in the thermally grown aluminium oxide (TGO) upon thermal cycling, and its relief by plastic deformation and fracture, were studied using luminescence spectroscopy. The TBCs with the LT Pt-Al bond coat failed by a rumpling mechanism that generated isolated cracks at the interface between the TGO and the YSZ. This reduced adhesion at this interface and the TBC delaminated when it could no longer resist the release of the stored elastic energy of the YSZ, which stiffened with time due to sintering. In contrast, the TBCs with Pt diffusion bond coats did not rumple, and the adhesion of interfaces in the coating did not obviously degrade. It is shown that the different failure mechanisms are strongly associated with differences in the high-temperature mechanical properties of the bond coats.

  18. Experimental demonstration of all-optical weak magnetic field detection using beam-deflection of single-mode fiber coated with cobalt-doped nickel ferrite nanoparticles.

    Science.gov (United States)

    Pradhan, Somarpita; Chaudhuri, Partha Roy

    2015-07-10

    We experimentally demonstrate single-mode optical-fiber-beam-deflection configuration for weak magnetic-field-detection using an optimized (low coercive-field) composition of cobalt-doped nickel ferrite nanoparticles. Devising a fiber-double-slit type experiment, we measure the surrounding magnetic field through precisely measuring interference-fringe yielding a minimum detectable field ∼100  mT and we procure magnetization data of the sample that fairly predicts SQUID measurement. To improve sensitivity, we incorporate etched single-mode fiber in double-slit arrangement and recorded a minimum detectable field, ∼30  mT. To further improve, we redefine the experiment as modulating fiber-to-fiber light-transmission and demonstrate the minimum field as 2.0 mT. The device will be uniquely suited for electrical or otherwise hazardous environments.

  19. Highly specific and rapid immuno-fluorescent visualization and detection of E. coli O104:H4 with protein-A coated magnetic beads based LST-MUG assay.

    Science.gov (United States)

    Barizuddin, Syed; Balakrishnan, Baskar; Stringer, R Cody; Dweik, Majed

    2015-08-01

    A method combining immunomagnetic separation and fluorescent sensing was developed to detect Escherichia coli (E. coli) O104:H4. The antibody specific to E. coli O104:H4 was immobilized on protein A-coated magnetic beads. This protein-A-anti E. coli O104:H4 complex was used to bind Fluorescein IsoThioCyanate (FITC) labeled E. coli O104:H4 antigen (whole cell) on it. The goal was to achieve a fluorescently detectable protein-A-anti E. coli O104:H4-E. coli O104:H4 complex on the magnetic beads. Fluorescent microscopy was used to image the magnetic beads. The resulting fluorescence on the beads was due to the FITC labeled antigen binding on the protein-A-anti E. coli O104:H4 immobilized magnetic beads. This visually proves the antigen-antibody binding. The fluorescent imaging results were obtained in 2 h if the minimum available bacteria in the sample were at least 10(5) CFU/ml. If no fluorescence was observed on the magnetic beads during fluorescent imaging, it indicates the bacterial concentration in the sample to be too low for it to have bound to the magnetic beads and hence no detection was possible. To detect bacterial concentration less than 10(5) CFU/ml in the sample, an additional step was required for detection. The magnetic bead complex was added to the LST-MUG (lauryl sulfate tryptose-4-methylumbelliferyl-β-D-glucuronide), a signaling reporter. The E. coli O104:H4 grows in LST-MUG and releases β-glucuronidase enzyme. This enzyme cleaves the MUG substrate that produces 4-methylumbelliferone, a highly fluorescent species. This fluorescence was detected using a spectrofluorometer. The emission peak in the fluorescent spectrum was found to be at 450 nm. The lower and upper detection range for this LST-MUG assay was found to be 2.05×10(5)-4.09×10(8) CFU/ml. The results for the LST-MUG assay for concentrations below 10(5) CFU/ml were ascertained in 8h. The advantages of this technique include the specific detection of bacteria without an enrichment step and

  20. Porous polymer coatings on metal microneedles for enhanced drug delivery

    Science.gov (United States)

    Ullah, Asad; Kim, Chul Min; Kim, Gyu Man

    2018-04-01

    We present a simple method to coat microneedles (MNs) uniformly with a porous polymer (PLGA) that can deliver drugs at high rates. Stainless steel (SS) MNs of high mechanical strength were coated with a thin porous polymer layer to enhance their delivery rates. Additionally, to improve the interfacial adhesion between the polymer and MNs, the MN surface was modified by plasma treatment followed by dip coating with polyethyleneimine, a polymer with repeating amine units. The average failure load (the minimum force sufficient for detaching the polymer layer from the surface of SS) recorded for the modified surface coating was 25 N, whereas it was 2.2 N for the non-modified surface. Calcein dye was successfully delivered into porcine skin to a depth of 750 µm by the porous polymer-coated MNs, demonstrating that the developed MNs can pierce skin easily without deformation of MNs; additional skin penetration tests confirmed this finding. For visual comparison, rhodamine B dye was delivered using porous-coated and non-coated MNs in gelatin gel which showed that delivery with porous-coated MNs penetrate deeper when compared with non-coated MNs. Finally, lidocaine and rhodamine B dye were delivered in phosphate-buffered saline (PBS) medium by porous polymer-coated and non-coated MNs. For rhodamine B, drug delivery with the porous-coated MNs was five times higher than that with the non-coated MNs, whereas 25 times more lidocaine was delivered by the porous-coated MNs compared with the non-coated MNs.