WorldWideScience

Sample records for coagulation contact phase

  1. Contact activation of blood-plasma coagulation

    Science.gov (United States)

    Golas, Avantika

    Surface engineering of biomaterials with improved hemocompatibility is an imperative, given the widespread global need for cardiovascular devices. Research summarized in this dissertation focuses on contact activation of FXII in buffer and blood plasma frequently referred to as autoactivation. The extant theory of contact activation imparts FXII autoactivation ability to negatively charged, hydrophilic surfaces. According to this theory, contact activation of plasma involves assembly of proteins comprising an "activation complex" on activating surfaces mediated by specific chemical interactions between complex proteins and the surface. This work has made key discoveries that significantly improve our core understanding of contact activation and unravel the existing paradigm of plasma coagulation. It is shown herein that contact activation of blood factor XII (FXII, Hageman factor) in neat-buffer solution exhibits a parabolic profile when scaled as a function of silanized-glass-particle activator surface energy (measured as advancing water adhesion tension t°a=g° Iv costheta in dyne/cm, where g°Iv is water interfacial tension in dyne/cm and theta is the advancing contact angle). Nearly equal activation is observed at the extremes of activator water-wetting properties --36 moderated by adsorption of plasma proteins unrelated to coagulation through an "adsorption-dilution" effect that blocks FXII contact with hydrophobic activator surfaces. The adsorption-dilution effect explains the apparent specificity for hydrophilic activators pursued by earlier investigators. Finally a comparison of FXII autoactivation in buffer, serum, protein cocktail, and plasma solutions is shown herein. Activation of blood plasma coagulation in vitro by contact with material surfaces is demonstrably dependent on plasma-volume-to-activator-surface-area ratio. However, activation of factor XII dissolved in buffer, protein cocktail, heat-denatured serum, and FXI deficient plasma does not

  2. The Mast Cell, Contact, and Coagulation System Connection in Anaphylaxis

    Directory of Open Access Journals (Sweden)

    Mar Guilarte

    2017-07-01

    Full Text Available Anaphylaxis is the most severe form of allergic reaction, resulting from the effect of mediators and chemotactic substances released by activated cells. Mast cells and basophils are considered key players in IgE-mediated human anaphylaxis. Beyond IgE-mediated activation of mast cells/basophils, further mechanisms are involved in the occurrence of anaphylaxis. New insights into the potential relevance of pathways other than mast cell and basophil degranulation have been unraveled, such as the activation of the contact and the coagulation systems. Mast cell heparin released upon activation provides negatively charged surfaces for factor XII (FXII binding and auto-activation. Activated FXII, the initiating serine protease in both the contact and the intrinsic coagulation system, activates factor XI and prekallikrein, respectively. FXII-mediated bradykinin (BK formation has been proven in the human plasma of anaphylactic patients as well as in experimental models of anaphylaxis. Moreover, the severity of anaphylaxis is correlated with the increase in plasma heparin, BK formation and the intensity of contact system activation. FXII also activates plasminogen in the fibrinolysis system. Mast cell tryptase has been shown to participate in fibrinolysis through plasmin activation and by facilitating the degradation of fibrinogen. Some usual clinical manifestations in anaphylaxis, such as angioedema or hypotension, or other less common, such as metrorrhagia, may be explained by the direct effect of the activation of the coagulation and contact system driven by mast cell mediators.

  3. Treatment of slaughter wastewater by coagulation sedimentation-anaerobic biological filter and biological contact oxidation process

    Science.gov (United States)

    Sun, M.; Yu, P. F.; Fu, J. X.; Ji, X. Q.; Jiang, T.

    2017-08-01

    The optimal process parameters and conditions for the treatment of slaughterhouse wastewater by coagulation sedimentation-AF - biological contact oxidation process were studied to solve the problem of high concentration organic wastewater treatment in the production of small and medium sized slaughter plants. The suitable water temperature and the optimum reaction time are determined by the experiment of precipitation to study the effect of filtration rate and reflux ratio on COD and SS in anaerobic biological filter and the effect of biofilm thickness and gas water ratio on NH3-N and COD in biological contact oxidation tank, and results show that the optimum temperature is 16-24°C, reaction time is 20 min in coagulating sedimentation, the optimum filtration rate is 0.6 m/h, and the optimum reflux ratio is 300% in anaerobic biological filter reactor. The most suitable biological film thickness range of 1.8-2.2 mm and the most suitable gas water ratio is 12:1-14:1 in biological contact oxidation pool. In the coupling process of continuous operation for 80 days, the average effluent’s mass concentrations of COD, TP and TN were 15.57 mg/L, 40 mg/L and 0.63 mg/L, the average removal rates were 98.93%, 86.10%, 88.95%, respectively. The coupling process has stable operation effect and good effluent quality, and is suitable for the industrial application.

  4. MR-guided noninvasive thermal coagulation of in-vivo liver tissue using ultrasonic phased array

    Science.gov (United States)

    Daum, Douglas R.; Smith, Nadine; McDannold, Nathan; Hynynen, Kullervo H.

    1999-05-01

    Magnetic resonance (MR) imaging was used to guide and monitor the thermal tissue coagulation of in vivo porcine tissue using a 256 element ultrasonic phased array. The array could coagulate tissue volumes greater than 2 cm3 in liver and 0.5 cm3 in kidney using a single 20 second sonication. This sonication used multiple focus fields which were temporally cycled to heat large tissue volumes simultaneously. Estimates of the coagulated tissue using a thermal dose threshold compare well with T2-weighted images of post sonication lesions. The overlapping large focal volumes could aid in the treatment of large tumor volumes which require multiple overlapping sonications. The ability of MR to detect the presence and undesirable thermal increases at acoustic obstacle such as cartilaginous and bony ribs is demonstrated. This could have a significant impact on the ability to monitor thermal treatments of the liver and other organs which are acoustically blocked.

  5. Phase formation in contact of dissimilar metals

    Energy Technology Data Exchange (ETDEWEB)

    Savvin, V S; Kazachkova, Yu A; Povzner, A A [Ural State Technical University-UPI, Mira st., 19, A-203, Yekaterinburg 620002 (Russian Federation)], E-mail: savvin-vs@yandex.ru

    2008-02-15

    Formation and growth of intermediate phases in contact of the crystalline samples forming a two-component eutectic system is considered. It is shown that during the competition to a growing liquid phase the intermediate solid phases cannot grow by diffusion. The alternative is formation of metastable areas of a liquid phase. Measurements of liquid layers extent in Pb-Bi and In-Bi systems have allowed to define the composition of liquid on interface where formation of metastable liquid is possible. The results show that the concentration interval of a liquid layer corresponds to a stable constitution diagram. In order to explain the experimental results the hypothesis according to which the intermediate solid phases are formed as a result of precipitation from metastable melt is considered. The experimental confirmation of formation and crystallization of a metastable liquid is the fact that intergrowth of the samples forming system with an intermetallic phase at temperatures below the temperature of fusion of the most low-melting eutectic is observed. The possibility of the processes concerned with the occurrence of metastable areas of a liquid is showed by means of computer imitation.

  6. Contact Stress Design Parameters for Titanium Bearings, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Air-Lock's Phase I effort tested the effects of ball induced contact stresses on Titanium bearing races. The contact stress design limit that would achieve a...

  7. Bias dependent specic contact resistance of phase change material to metal contacts

    NARCIS (Netherlands)

    Roy, Deepu; in 't Zandt, Micha; Wolters, Robertus A.M.

    2010-01-01

    Knowledge of contact resistance of phase change materials (PCM) to metal electrodes is important for scaling, device modeling and optimization of phase change random access memory (PCRAM) cells. In this article, we report the systematic determination of the speci_c contact resistance (_c) with

  8. The Interplay between Inflammation, Coagulation and Endothelial Injury in the Early Phase of Acute Pancreatitis: Clinical Implications

    Directory of Open Access Journals (Sweden)

    Paulina Dumnicka

    2017-02-01

    Full Text Available Acute pancreatitis (AP is an inflammatory disease with varied severity, ranging from mild local inflammation to severe systemic involvement resulting in substantial mortality. Early pathologic events in AP, both local and systemic, are associated with vascular derangements, including endothelial activation and injury, dysregulation of vasomotor tone, increased vascular permeability, increased leukocyte migration to tissues, and activation of coagulation. The purpose of the review was to summarize current evidence regarding the interplay between inflammation, coagulation and endothelial dysfunction in the early phase of AP. Practical aspects were emphasized: (1 we summarized available data on diagnostic usefulness of the markers of endothelial dysfunction and activated coagulation in early prediction of severe AP; (2 we reviewed in detail the results of experimental studies and clinical trials targeting coagulation-inflammation interactions in severe AP. Among laboratory tests, d-dimer and angiopoietin-2 measurements seem the most useful in early prediction of severe AP. Although most clinical trials evaluating anticoagulants in treatment of severe AP did not show benefits, they also did not show significantly increased bleeding risk. Promising results of human trials were published for low molecular weight heparin treatment. Several anticoagulants that proved beneficial in animal experiments are thus worth testing in patients.

  9. Numerical methods for two-phase flow with contact lines

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Clauido

    2012-07-01

    This thesis focuses on numerical methods for two-phase flows, and especially flows with a moving contact line. Moving contact lines occur where the interface between two fluids is in contact with a solid wall. At the location where both fluids and the wall meet, the common continuum descriptions for fluids are not longer valid, since the dynamics around such a contact line are governed by interactions at the molecular level. Therefore the standard numerical continuum models have to be adjusted to handle moving contact lines. In the main part of the thesis a method to manipulate the position and the velocity of a contact line in a two-phase solver, is described. The Navier-Stokes equations are discretized using an explicit finite difference method on a staggered grid. The position of the interface is tracked with the level set method and the discontinuities at the interface are treated in a sharp manner with the ghost fluid method. The contact line is tracked explicitly and its dynamics can be described by an arbitrary function. The key part of the procedure is to enforce a coupling between the contact line and the Navier-Stokes equations as well as the level set method. Results for different contact line models are presented and it is demonstrated that they are in agreement with analytical solutions or results reported in the literature.The presented Navier-Stokes solver is applied as a part in a multiscale method to simulate capillary driven flows. A relation between the contact angle and the contact line velocity is computed by a phase field model resolving the micro scale dynamics in the region around the contact line. The relation of the microscale model is then used to prescribe the dynamics of the contact line in the macro scale solver. This approach allows to exploit the scale separation between the contact line dynamics and the bulk flow. Therefore coarser meshes can be applied for the macro scale flow solver compared to global phase field simulations

  10. Autovalidation and automation of the postanalytical phase of routine hematology and coagulation analyses in a university hospital laboratory.

    Science.gov (United States)

    Mlinaric, Ana; Milos, Marija; Coen Herak, Désirée; Fucek, Mirjana; Rimac, Vladimira; Zadro, Renata; Rogic, Dunja

    2018-02-23

    The need to satisfy high-throughput demands for laboratory tests continues to be a challenge. Therefore, we aimed to automate postanalytical phase in hematology and coagulation laboratory by autovalidation of complete blood count (CBC) and routine coagulation test results (prothrombin time [PT], international normalized ratio [PT-INR], activated partial thromboplastin time [APTT], fibrinogen, antithrombin activity [AT] and thrombin time [TT]). Work efficacy and turnaround time (TAT) before and after implementation of automated solutions will be compared. Ordering panels tailored to specific patient populations were implemented. Rerun and reflex testing rules were set in the respective analyzers' software (Coulter DxH Connectivity 1601, Beckman Coulter, FL, USA; AutoAssistant, Siemens Healthcare Diagnostics, Germany), and sample status information was transferred into the laboratory information system. To evaluate if the automation improved TAT and efficacy, data from manually verified results in September and October of 2015 were compared with the corresponding period in 2016 when autovalidation was implemented. Autovalidation rates of 63% for CBC and 65% for routine coagulation test results were achieved. At the TAT of 120 min, the percentage of reported results increased substantially for all analyzed tests, being above 90% for CBC, PT, PT-INR and fibrinogen and 89% for APTT. This output was achieved with three laboratory technicians less compared with the period when the postanalytical phase was not automated. Automation allowed optimized laboratory workflow for specific patient populations, thereby ensuring standardized results reporting. Autovalidation of test results proved to be an efficient tool for improvement of laboratory work efficacy and TAT.

  11. Experimental investigation of direct contact three phase boiling heat transfer

    International Nuclear Information System (INIS)

    Bruce, W.D.

    1981-01-01

    The system which was studied in the present work consisted of one liquid undergoing vaporization by contact with a hotter immiscible liquid. The liquids and vapor were contacted in a counterflow spray column with only differential increases in vapor quality. Experiments yielded vertical temperature profiles, flow rates of the phases, liquid holdups, pressure drops, and a characterization of flow patterns. A micro-computer was utilized for measuring temperatures in the column at the rate of 1500 to 1600 times per second at several depths. Analysis of the experimental data indicate that the maximum temperature difference between the phases is 0.5F 0 , and that a temperature crossover occurs at the lower end of the column. The heat transfer fluid undergoes flash vaporization at its inlet at the top of the column, and much of its sensible heat is tranferred to the dispersed phase near the top of the column. Temperature profiles along the length of the boiler are nearly flat, and very little heat transfer occurs in the lower part of the boiler. A chemical method was developed for measuring effective interfacial area in a direct contact boiler. The theoretical basis of the method is discussed, and physico-chemical data necessary for application of the technique are reported. Water solubility of methyl salicylate was measured as a function of temperature, and the second order reaction rate coefficient for saponification of methyl salicylate by sodium hydroxide was determined from sodium hydroxide concentration versus time data and a computer model of a well-mixed semibatch reactor. The activation energy for the reaction was found to be 9.58 kilocalories per gram mole

  12. Innovative separation and preconcentration technique of coagulating homogenous dispersive micro solid phase extraction exploiting graphene oxide nanosheets

    Energy Technology Data Exchange (ETDEWEB)

    Ghazaghi, Mehri [Department of Chemistry, College of Science, Semnan University, P.O. Box: 35131-19111, Semnan (Iran, Islamic Republic of); Mousavi, Hassan Zavvar, E-mail: hzmousavi@semnan.ac.ir [Department of Chemistry, College of Science, Semnan University, P.O. Box: 35131-19111, Semnan (Iran, Islamic Republic of); Rashidi, Ali Morad [Nanotechnology Research Center, Research Institute of Petroleum Industry (RIPI), West Entrance Blvd., Olympic Village, P.O. Box: 14857-33111, Tehran (Iran, Islamic Republic of); Shirkhanloo, Hamid [Occupational and Environmental Health Research Center (OEHRC), Iranian Petroleum Industry Health Research Institute (IPIHRI), Tehran (Iran, Islamic Republic of); Rahighi, Reza [Nanotechnology Research Center, Research Institute of Petroleum Industry (RIPI), West Entrance Blvd., Olympic Village, P.O. Box: 14857-33111, Tehran (Iran, Islamic Republic of); Department of Research and Development, Sharif Ultrahigh Nanotechnologists (SUN) Company, P.O. Box: 13488-96394, Tehran (Iran, Islamic Republic of)

    2016-01-01

    A uniquely novel, fast, and facile technique is introduced for the first time in which a scant amount of graphene oxide (GO), without modification, has been utilized in dispersive mode of solid phase extraction (SPE) for an efficient yet simple separation. The proposed method of coagulating homogenous dispersive micro solid phase extraction (CHD-µSPE) is based on coagulation of homogeneous GO solution with the aid of polyetheneimine (PEI). CHD-µSPE use full adsorption capacity of GO because in this method was used GO solution obtained from synthesis process without drying step and stacking nanosheets. In optimized condition, 30 µL GO solution (7 mg mL{sup −1}), obtained in synthesis process, was injected into 1.5 mL the sample solution followed by immediate injection of 53 µL PEI solution (1 mg mL{sup −1}). After inserting PEI, GO sheets aggregate and can be readily separated by centrifugation. PEI not only cause aggregation of GO, but also form three-dimensional network of GO with easy handling in following separation steps. Lead, cadmium, and chromium were selected as model analytes and the effecting parameters including the amount of GO, concentration of PEI, sample pH, extraction time, and type of desorption solvent were investigated and optimized. The results indicate that the proposed CHD-µSPE method can be successfully applied GO in dispersive mode of SPE without effecting on good capability adsorption of GO. The novel method was applied in determination of lead, cadmium, and chromium in water, human saliva, and urine samples by electrothermal atomic absorption spectrometry. The detection limits are as low as 0.035, 0.005, and 0.012 µg L{sup −1} for Pb, Cd, and Cr respectively. The intra-day precisions (RSDs) were lower than 3.8%. CHD-µSPE method showed a good linear ranges of 0.24–15.6, 0.015–0.95 and 0.039–2.33 µg L{sup −1} for Pb, Cd and Cr respectively. Method performance was investigated by determination of mentioned

  13. Innovative separation and preconcentration technique of coagulating homogenous dispersive micro solid phase extraction exploiting graphene oxide nanosheets.

    Science.gov (United States)

    Ghazaghi, Mehri; Mousavi, Hassan Zavvar; Rashidi, Ali Morad; Shirkhanloo, Hamid; Rahighi, Reza

    2016-01-01

    A uniquely novel, fast, and facile technique is introduced for the first time in which a scant amount of graphene oxide (GO), without modification, has been utilized in dispersive mode of solid phase extraction (SPE) for an efficient yet simple separation. The proposed method of coagulating homogenous dispersive micro solid phase extraction (CHD-µSPE) is based on coagulation of homogeneous GO solution with the aid of polyetheneimine (PEI). CHD-µSPE use full adsorption capacity of GO because in this method was used GO solution obtained from synthesis process without drying step and stacking nanosheets. In optimized condition, 30 µL GO solution (7 mg mL(-1)), obtained in synthesis process, was injected into 1.5 mL the sample solution followed by immediate injection of 53 µL PEI solution (1 mg mL(-1)). After inserting PEI, GO sheets aggregate and can be readily separated by centrifugation. PEI not only cause aggregation of GO, but also form three-dimensional network of GO with easy handling in following separation steps. Lead, cadmium, and chromium were selected as model analytes and the effecting parameters including the amount of GO, concentration of PEI, sample pH, extraction time, and type of desorption solvent were investigated and optimized. The results indicate that the proposed CHD-µSPE method can be successfully applied GO in dispersive mode of SPE without effecting on good capability adsorption of GO. The novel method was applied in determination of lead, cadmium, and chromium in water, human saliva, and urine samples by electrothermal atomic absorption spectrometry. The detection limits are as low as 0.035, 0.005, and 0.012 µg L(-1) for Pb, Cd, and Cr respectively. The intra-day precisions (RSDs) were lower than 3.8%. CHD-µSPE method showed a good linear ranges of 0.24-15.6, 0.015-0.95 and 0.039-2.33 µg L(-1) for Pb, Cd and Cr respectively. Method performance was investigated by determination of mentioned metal ions in river water, human urine and

  14. Speci﬿c contact resistance of phase change materials to metal electrode

    NARCIS (Netherlands)

    Roy, Deepu; in 't Zandt, Micha A.A.; Wolters, Robertus A.M.

    2010-01-01

    For phase change random access memory (PCRAM) cells, it is important to know the contact resistance of phase change materials (PCMs) to metal electrodes at the contacts. In this letter, we report the systematic determination of the speci﬿c contact resistance (Ͽc ) of doped Sb2Te and Ge2Sb2Te5 to TiW

  15. Heat transfer modelling of two-phase bubbles swarm condensing in three - phase direct - contact condenser

    Directory of Open Access Journals (Sweden)

    Mahood Hameed B.

    2016-01-01

    Full Text Available An analytical model for the convective heat transfer coefficient and the two-phase bubble size of a three-phase direct contact heat exchanger was developed. Until the present, there has only been a theoretical model available that deals with a single two-phase bubble and a bubble train condensation in an immiscible liquid. However, to understand the actual heat transfer process within the three-phase direct contact condenser, characteristic models are required. A quasi - steady energy equation in a spherical coordinate system with a potential flow assumption and a cell model configuration has been simplified and solved analytically. The convective heat transfer in terms of Nu number has been derived, and it was found to be a function to Pe number and a system void fraction. In addition, the two-phase bubble size relates to the system void fraction and has been developed by solving a simple energy balance equation and using the derived convective heat transfer coefficient expression. Furthermore, the model correlates well with previous experimental data and theoretical results.

  16. A Randomized, Double-Blind, Placebo-Controlled, Phase 2b Study to Evaluate the Safety and Efficacy of Recombinant Human Soluble Thrombomodulin, ART-123, in Patients With Sepsis and Suspected Disseminated Intravascular Coagulation

    NARCIS (Netherlands)

    Vincent, Jean-Louis; Ramesh, Mayakonda K.; Ernest, David; Larosa, Steven P.; Pachl, Jan; Aikawa, Naoki; Hoste, Eric; Levy, Howard; Hirman, Joe; Levi, Marcel; Daga, Mradul; Kutsogiannis, Demetrios J.; Crowther, Mark; Bernard, Gordon R.; Devriendt, Jacques; Puigserver, Joan Vidal; Blanzaco, Daniel U.; Esmon, Charles T.; Parrillo, Joseph E.; Guzzi, Louis; Henderson, Seton J.; Pothirat, Chaicharn; Mehta, Parthiv; Fareed, Jawed; Talwar, Deepak; Tsuruta, Kazuhisa; Gorelick, Kenneth J.; Osawa, Yutaka; Kaul, Inder

    2013-01-01

    Objectives: To determine the safety and efficacy of recombinant thrombomodulin (ART-123) in patients with suspected sepsis-associated disseminated intravascular coagulation. Design: Phase 2b, international, multicenter, double-blind, randomized, placebo-controlled, parallel group, screening trial.

  17. Effects of Phase Difference Between Axial and Contact loads on Fretting Fatigue Behavior of Titanium Alloy

    National Research Council Canada - National Science Library

    Almajali, Mohammad

    2006-01-01

    .... Most of the previous works were accomplished under a constant applied normal load and a little effort was done under a variable contact load, while none of these studies have considered the phase...

  18. Freeform optics: a non-contact "test plate" for manufacturing, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this NASA SBIR Phase I study is to determine the feasibility of measuring precision (fractional wave) freeform optics using non-contact areal (imaging)...

  19. Generic two-phase coexistence in the quadratic contact process

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Xiaofang [Iowa State Univ., Ames, IA (United States)

    2009-01-01

    This thesis focuses on the demonstration of the existence of and analysis of phenomena related to the discontinuous non-equilibrium phase transition between an active (or reactive) state and a poisoned (or extinguished) state occurring in a stochastic lattice-gas realization of Schloegl’s second model for autocatalysis.

  20. Photosensitized Oxygenations of Hexamethylbenzene in Phase Contact Enhanced Microreactor

    International Nuclear Information System (INIS)

    Park, Chan Yi; Park, Jeong Hyeon; Lim Hyo Jin; Hwang, Geumsook; Park, Chan Pil

    2014-01-01

    Activated singlet oxygen ( 1 O 2 ) has successfully been utilized in production of various compounds including fragrances, pharmaceuticals, and fine chemicals. However, the traditional reaction required a prolonged reaction time due to the difficulty of introducing adequate light and oxygen into the solution. Low contact probability between four species of oxygen, photosensitizer, light, and reagent is an inherent drawback of the traditional photoreaction. Molecular diffusion distance is the most important factor in the heterogeneous reactions including gas-liquid, gassolid, liquid-solid, and immiscible liquid-liquid. Therefore, rates of reaction are closely depended on the distance. Microreactor has provided a distinct advantage in the short molecular diffusion distance due to the high surface-to-volume ratio driven by narrow fluidic channels

  1. Alpha 1-antitrypsin Pittsburgh (Met358-->Arg) inhibits the contact pathway of intrinsic coagulation and alters the release of human neutrophil elastase during simulated extracorporeal circulation

    NARCIS (Netherlands)

    Wachtfogel, Y.T.; Bischoff, Rainer; Bauer, R; Hack, C.E.; Nuijens, J.H; Kucich, U.; Niewiarowski, S.; Edmunds, Jr. L.H.; Colman, R.W.

    1994-01-01

    Cardiopulmonary bypass prolongs bleeding time, increases postoperative blood loss, and triggers activation of plasma proteolytic enzyme systems and blood cells referred to as the "whole body inflammatory response". Contact of blood with synthetic surfaces leads to qualitative and quantitative

  2. Thermodynamics and phase equilibria of ternary systems relevant to contact materials for compound semiconductors

    International Nuclear Information System (INIS)

    Ipser, H.; Richter, K.; Micke, K.

    1997-01-01

    In order to investigate the stability of ohmic contacts to compound semiconductors, it is necessary to know the phase equilibria in the corresponding multi-component systems. We are currently studying the phase equilibria and thermophysical properties of several ternary systems which are of interest in view of the use of nickel, palladium and platinum as contact materials for GaSb and InSb compound semiconductors: Ga-Ni-Sb, In-Ni-Sb, Ga-Pd-Sb and Ga-Pt-Sb. Phase equilibria are investigated by thermal analyses, X-ray powder diffraction methods as well as electron microprobe analysis. Thermodynamic properties are derived from vapour pressure measurements using an isopiestic method. It is planned to combine all information on phase equilibria and thermochemistry for the ternary and the limiting binary systems to perform an optimization of the ternary systems by computer calculations using standard software. (author)

  3. Normal Coagulation

    Science.gov (United States)

    2014-09-04

    factor VIII, or hemophilia A, is a well- characterized bleeding disorder linked to the X chromosome . Severe hemophilia A therefore occurs almost... disappears from the fluid phase of the reaction. Thus, the “initial clot” is a mixture composed of fibrin and fibrinogen. with the somatomedin B

  4. Process Intensification. Continuous Two-Phase Catalytic Reactions in a Table-Top Centrifugal Contact Separator

    NARCIS (Netherlands)

    Kraai, Gerard N.; Schuur, Boelo; van Zwol, Floris; Haak, Robert M.; Minnaard, Adriaan J.; Feringa, Ben L.; Heeres, Hero J.; de Vries, Johannes G.; Prunier, ML

    2009-01-01

    Production of fine chemicals is mostly performed in batch reactors. Use of continuous processes has many advantages which may reduce the cost of production. We have developed the use of centrifugal contact separators (CCSs) for continuous two-phase catalytic reactions. This equipment has previously

  5. Contact line motion in confined liquid–gas systems: Slip versus phase transition

    KAUST Repository

    Xu, Xinpeng

    2010-11-30

    In two-phase flows, the interface intervening between the two fluid phases intersects the solid wall at the contact line. A classical problem in continuum fluid mechanics is the incompatibility between the moving contact line and the no-slip boundary condition, as the latter leads to a nonintegrable stress singularity. Recently, various diffuse-interface models have been proposed to explain the contact line motion using mechanisms missing from the sharp-interface treatments in fluid mechanics. In one-component two-phase (liquid–gas) systems, the contact line can move through the mass transport across the interface while in two-component (binary) fluids, the contact line can move through diffusive transport across the interface. While these mechanisms alone suffice to remove the stress singularity, the role of fluid slip at solid surface needs to be taken into account as well. In this paper, we apply the diffuse-interface modeling to the study of contact line motion in one-component liquid–gas systems, with the fluid slip fully taken into account. The dynamic van der Waals theory has been presented for one-component fluids, capable of describing the two-phase hydrodynamics involving the liquid–gas transition [A. Onuki, Phys. Rev. E 75, 036304 (2007)]. This theory assumes the local equilibrium condition at the solid surface for density and also the no-slip boundary condition for velocity. We use its hydrodynamicequations to describe the continuum hydrodynamics in the bulk region and derive the more general boundary conditions by introducing additional dissipative processes at the fluid–solid interface. The positive definiteness of entropy production rate is the guiding principle of our derivation. Numerical simulations based on a finite-difference algorithm have been carried out to investigate the dynamic effects of the newly derived boundary conditions, showing that the contact line can move through both phase transition and slip, with their relative

  6. Properties predictive modeling through the concept of a hybrid interphase existing between phases in contact

    Science.gov (United States)

    Portan, D. V.; Papanicolaou, G. C.

    2018-02-01

    From practical point of view, predictive modeling based on the physics of composite material behavior is wealth generating; by guiding material system selection and process choices, by cutting down on experimentation and associated costs; and by speeding up the time frame from the research stage to the market place. The presence of areas with different properties and the existence of an interphase between them have a pronounced influence on the behavior of a composite system. The Viscoelastic Hybrid Interphase Model (VHIM), considers the existence of a non-homogeneous viscoelastic and anisotropic interphase having properties depended on the degree of adhesion between the two phases in contact. The model applies for any physical/mechanical property (e.g. mechanical, thermal, electrical and/or biomechanical). Knowing the interphasial variation of a specific property one can predict the corresponding macroscopic behavior of the composite. Moreover, the model acts as an algorithm and a two-way approach can be used: (i) phases in contact may be chosen to get the desired properties of the final composite system or (ii) the initial phases in contact determine the final behavior of the composite system, that can be approximately predicted. The VHIM has been proven, amongst others, to be extremely useful in biomaterial designing for improved contact with human tissues.

  7. Novel Sn-Based Contact Structure for GeTe Phase Change Materials.

    Science.gov (United States)

    Simchi, Hamed; Cooley, Kayla A; Ding, Zelong; Molina, Alex; Mohney, Suzanne E

    2018-05-16

    Germanium telluride (GeTe) is a phase change material (PCM) that has gained recent attention because of its incorporation as an active material for radio frequency (RF) switches, as well as memory and novel optoelectronic devices. Considering PCM-based RF switches, parasitic resistances from Ohmic contacts can be a limiting factor in device performance. Reduction of the contact resistance ( R c ) is therefore critical for reducing the on-state resistance to meet the requirements of high-frequency RF applications. To engineer the Schottky barrier between the metal contact and GeTe, Sn was tested as an interesting candidate to alter the composition of the semiconductor near its surface, potentially forming a narrow band gap (0.2 eV) SnTe or a graded alloy with SnTe in GeTe. For this purpose, a novel contact stack of Sn/Fe/Au was employed and compared to a conventional Ti/Pt/Au stack. Two different premetallization surface treatments of HCl and deionized (DI) H 2 O were employed to make a Te-rich and Ge-rich interface, respectively. Contact resistance values were extracted using the refined transfer length method. The best results were obtained with DI H 2 O for the Sn-based contacts but HCl treatment for the Ti/Pt/Au contacts. The as-deposited contacts had the R c (ρ c ) of 0.006 Ω·mm (8 × 10 -9 Ω·cm 2 ) for Sn/Fe/Au and 0.010 Ω·mm (3 × 10 -8 Ω·cm 2 ) for Ti/Pt/Au. However, the Sn/Fe/Au contacts were thermally stable, and their resistance decreased further to 0.004 Ω·mm (4 × 10 -9 Ω·cm 2 ) after annealing at 200 °C. In contrast, the contact resistance of the Ti/Pt/Au stack increased to 0.012 Ω·mm (4 × 10 -8 Ω·cm 2 ). Transmission electron microscopy was used to characterize the interfacial reactions between the metals and GeTe. It was found that formation of SnTe at the interface, in addition to Fe diffusion (doping) into GeTe, is likely responsible for the superior performance of Sn/Fe/Au contacts, resulting in one of the lowest reported

  8. Phase change predictions for liquid fuel in contact with steel structure using the heat conduction equation

    Energy Technology Data Exchange (ETDEWEB)

    Brear, D.J. [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1998-01-01

    When liquid fuel makes contact with steel structure the liquid can freeze as a crust and the structure can melt at the surface. The melting and freezing processes that occur can influence the mode of fuel freezing and hence fuel relocation. Furthermore the temperature gradients established in the fuel and steel phases determine the rate at which heat is transferred from fuel to steel. In this memo the 1-D transient heat conduction equations are applied to the case of initially liquid UO{sub 2} brought into contact with solid steel using up-to-date materials properties. The solutions predict criteria for fuel crust formation and steel melting and provide a simple algorithm to determine the interface temperature when one or both of the materials is undergoing phase change. The predicted steel melting criterion is compared with available experimental results. (author)

  9. Phase change predictions for liquid fuel in contact with steel structure using the heat conduction equation

    International Nuclear Information System (INIS)

    Brear, D.J.

    1998-01-01

    When liquid fuel makes contact with steel structure the liquid can freeze as a crust and the structure can melt at the surface. The melting and freezing processes that occur can influence the mode of fuel freezing and hence fuel relocation. Furthermore the temperature gradients established in the fuel and steel phases determine the rate at which heat is transferred from fuel to steel. In this memo the 1-D transient heat conduction equations are applied to the case of initially liquid UO 2 brought into contact with solid steel using up-to-date materials properties. The solutions predict criteria for fuel crust formation and steel melting and provide a simple algorithm to determine the interface temperature when one or both of the materials is undergoing phase change. The predicted steel melting criterion is compared with available experimental results. (author)

  10. Mixed-order phase transition of the contact process near multiple junctions.

    Science.gov (United States)

    Juhász, Róbert; Iglói, Ferenc

    2017-02-01

    We have studied the phase transition of the contact process near a multiple junction of M semi-infinite chains by Monte Carlo simulations. As opposed to the continuous transitions of the translationally invariant (M=2) and semi-infinite (M=1) system, the local order parameter is found to be discontinuous for M>2. Furthermore, the temporal correlation length diverges algebraically as the critical point is approached, but with different exponents on the two sides of the transition. In the active phase, the estimate is compatible with the bulk value, while in the inactive phase it exceeds the bulk value and increases with M. The unusual local critical behavior is explained by a scaling theory with an irrelevant variable, which becomes dangerous in the inactive phase. Quenched spatial disorder is found to make the transition continuous in agreement with earlier renormalization group results.

  11. Droplets and the three-phase contact line at the nano-scale. Statics and dynamics

    Science.gov (United States)

    Yatsyshin, Petr; Sibley, David; Savva, Nikos; Kalliadasis, Serafim

    2014-11-01

    Understanding the behaviour of the solid-liquid-vapour contact line at the scale of several tens of molecular diameters is important in wetting hydrodynamics with applications in micro- and nano-fluidics, including the design of lab-on-a-chip devices and surfaces with specific wetting properties. Due to the fluid inhomogeneity at the nano-scale, the application of continuum-mechanical approaches is limited, and a natural way to remedy this is to seek descriptions accounting for the non-local molecular-level interactions. Density Functional Theory (DFT) for fluids offers a statistical-mechanical framework based on expressing the free energy of the fluid-solid pair as a functional of the spatially varying fluid density. DFT allows us to investigate small drops deposited on planar substrates whilst keeping track of the microscopic structural details of the fluid. Starting from a model of intermolecular forces, we systematically obtain interfaces, surface tensions, and the microscopic contact angle. Using a dynamic extension of equilibrium DFT, we investigate the diffusion-driven evolution of the three-phase contact line to gain insight into the dynamic behaviour of the microscopic contact angle, which is still under debate.

  12. IMPROVEMENT OF COAGULATION PROCESS FOR THE PRUT RIVER WATER TREATMENT USING ALUMINUM SULPHATE

    Directory of Open Access Journals (Sweden)

    Larisa Postolachi

    2015-06-01

    Full Text Available The aim of presented research was to optimize the treatment process of the Prut River water. In order to realize the proposed goal, there were studied the following factors which can improve the process of coagulation: (i the influence of stirring speed during coagulation and (ii the influence of the concentration of the coagulant solution added in the process of coagulation. The optimal conditions of coagulation were established using the Jar-test method. Application of the recommended procedure contribute to the reduction of the coagulant dose, the contact time, the aluminum concentration in water and the expenses for water treatment.

  13. A finite-element model for moving contact line problems in immiscible two-phase flow

    Science.gov (United States)

    Kucala, Alec

    2017-11-01

    Accurate modeling of moving contact line (MCL) problems is imperative in predicting capillary pressure vs. saturation curves, permeability, and preferential flow paths for a variety of applications, including geological carbon storage (GCS) and enhanced oil recovery (EOR). The macroscale movement of the contact line is dependent on the molecular interactions occurring at the three-phase interface, however most MCL problems require resolution at the meso- and macro-scale. A phenomenological model must be developed to account for the microscale interactions, as resolving both the macro- and micro-scale would render most problems computationally intractable. Here, a model for the moving contact line is presented as a weak forcing term in the Navier-Stokes equation and applied directly at the location of the three-phase interface point. The moving interface is tracked with the level set method and discretized using the conformal decomposition finite element method (CDFEM), allowing for the surface tension and the wetting model to be computed at the exact interface location. A variety of verification test cases for simple two- and three-dimensional geometries are presented to validate the current MCL model, which can exhibit grid independence when a proper scaling for the slip length is chosen. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA-0003525.

  14. Results of a phase I/II open-label, safety and efficacy trial of coagulation factor IX (recombinant), albumin fusion protein in haemophilia B patients.

    Science.gov (United States)

    Martinowitz, U; Lissitchkov, T; Lubetsky, A; Jotov, G; Barazani-Brutman, T; Voigt, C; Jacobs, I; Wuerfel, T; Santagostino, E

    2015-11-01

    rIX-FP is a coagulation factor IX (recombinant), albumin fusion protein with more than fivefold half-life prolongation over other standard factor IX (FIX) products available on the market. This prospective phase II, open-label study evaluated the safety and efficacy of rIX-FP for the prevention of bleeding episodes during weekly prophylaxis and assessed the haemostatic efficacy for on-demand treatment of bleeding episodes in previously treated patients with haemophilia B. The study consisted of a 10-14 day evaluation of rIX-FP pharmacokinetics (PK), and an 11 month safety and efficacy evaluation period with subjects receiving weekly prophylaxis treatment. Safety was evaluated by the occurrence of related adverse events, and immunogenic events, including development of inhibitors. Efficacy was evaluated by annualized spontaneous bleeding rate (AsBR), and the number of injections to achieve haemostasis. Seventeen subjects participated in the study, 13 received weekly prophylaxis and 4 received episodic treatment only. No inhibitors were detected in any subject. The mean and median AsBR were 1.25, and 1.13 respectively in the weekly prophylaxis arm. All bleeding episodes were treated with 1 or 2 injections of rIX-FP. Three prophylaxis subjects who were treated on demand prior to study entry had >85% reduction in AsBR compared to the bleeding rate prior to study entry. This study demonstrated the efficacy for weekly routine prophylaxis of rIX-FP to prevent spontaneous bleeding episodes and for the treatment of bleeding episodes. In addition no safety issues were detected during the study and an improved PK profile was demonstrated. © 2015 CSL Behring. Haemophilia published by John Wiley & Sons Ltd.

  15. Biomechanical analysis of the contact phase in drop jumps performed in water and on dry land

    Directory of Open Access Journals (Sweden)

    Caroline Ruschel

    2016-03-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2016v18n1p41   Plyometric training in the aquatic environment has been used as way of reducing loads through the action of buoyancy. However, little is known about the biomechanical characteristics of plyometric exercises in water, which can assist in the prescription of training in this environment. This study aimed to analyze the vertical component of the ground reaction force and contact duration of drop jumps (DJ performed on land and at hip level water immersion. Participants were 22 male athletes (19.1 ± 3.7 years, who performed three maximum DJs in water and on dry land. Peak force and duration of braking and propulsion sub-phases of the DJ contact were analyzed with the use of two underwater force platforms, a 2-D waterproofed electrogoniometer, acquisition systems ADS2000-IP and TeleMyo 2400TG2, and a signal synchronizer. The effect of immersion was investigated through comparison tests for dependent samples (p <0.05. In water, the following results were observed: (a reduction of 41.8% (p <0.001, d = 2.24 and 23.8% (p <0.001, d = 1.50 of peak forces during braking and propulsion sub-phases respectively; and (b increase of 41.8% in the braking (p <0.001, d = 1.41 and 12.3% in the propulsion contact times (p = 0.006, d = 0.75. The aquatic environment can be an alternative when one aims to reduce the load during the DJ contact; however, the longer duration increasing of contact sub-phases in water at hip immersion may compromise the proper functioning of the stretch-shortening cycle in water.

  16. Study and Experiment on Non-Contact Voltage Sensor Suitable for Three-Phase Transmission Line.

    Science.gov (United States)

    Zhou, Qiang; He, Wei; Xiao, Dongping; Li, Songnong; Zhou, Kongjun

    2015-12-30

    A voltage transformer, as voltage signal detection equipment, plays an important role in a power system. Presently, more and more electric power systems are adopting potential transformer and capacitance voltage transformers. Transformers are often large in volume and heavyweight, their insulation design is difficult, and an iron core or multi-grade capacitance voltage division structure is generally adopted. As a result, the detection accuracy of transformer is reduced, a huge phase difference exists between detection signal and voltage signal to be measured, and the detection signal cannot accurately and timely reflect the change of conductor voltage signal to be measured. By aiming at the current problems of electric transformation, based on electrostatic induction principle, this paper designed a non-contact voltage sensor and gained detection signal of the sensor through electrostatic coupling for the electric field generated by electric charges of the conductor to be measured. The insulation structure design of the sensor is simple and its volume is small; phase difference of sensor measurement is effectively reduced through optimization design of the electrode; and voltage division ratio and measurement accuracy are increased. The voltage sensor was tested on the experimental platform of simulating three-phase transmission line. According to the result, the designed non-contact voltage sensor can realize accurate and real-time measurement for the conductor voltage. It can be applied to online monitoring for the voltage of three-phase transmission line or three-phase distribution network line, which is in accordance with the development direction of the smart grid.

  17. Large-Area, Multi-Junction, Epitaxial Lift-Off Solar Cells with Backside Contacts, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase II program we propose to develop a manufacturable production process to introduce backside contacts to MicroLink Devices? large-area, multi-junction...

  18. Large-Area, Multi-Junction, Epitaxial Lift-Off Solar Cells with Backside Contacts, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase I program we propose to develop an innovative fabrication process to introduce backside contacts to MicroLink Devices' large-area, multi-junction...

  19. Theories of blood coagulation.

    Science.gov (United States)

    Riddel, James P; Aouizerat, Bradley E; Miaskowski, Christine; Lillicrap, David P

    2007-01-01

    Although the concept of the coagulation cascade represented a significant advance in the understanding of coagulation and served for many years as a useful model, more recent clinical and experimental observations demonstrate that the cascade/waterfall hypothesis does not fully and completely reflect the events of hemostasis in vivo. The goal of this article is to review the evolution of the theories of coagulation and their proposed models to serve as a tool when reviewing the research and practice literature that was published in the context of these different theories over time.

  20. Dust coagulation in ISM

    Science.gov (United States)

    Chokshi, Arati; Tielens, Alexander G. G. M.; Hollenbach, David

    1989-01-01

    Coagulation is an important mechanism in the growth of interstellar and interplanetary dust particles. The microphysics of the coagulation process was theoretically analyzed as a function of the physical properties of the coagulating grains, i.e., their size, relative velocities, temperature, elastic properties, and the van der Waal interaction. Numerical calculations of collisions between linear chains provide the wave energy in individual particles and the spectrum of the mechanical vibrations set up in colliding particles. Sticking probabilities are then calculated using simple estimates for elastic deformation energies and for the attenuation of the wave energy due to absorption and scattering processes.

  1. Hybrid Smith predictor and phase lead based divergence compensation for hardware-in-the-loop contact simulation with measurement delay

    Science.gov (United States)

    Qi, Chenkun; Gao, Feng; Zhao, Xianchao; Wang, Qian; Ren, Anye

    2018-06-01

    On the ground the hardware-in-the-loop (HIL) simulation is a good approach to test the contact dynamics of spacecraft docking process in space. Unfortunately, due to the time delay in the system the HIL contact simulation becomes divergent. However, the traditional first-order phase lead compensation approach still result in a small divergence for the pure time delay. The serial Smith predictor and phase lead compensation approach proposed by the authors recently will lead to an over-compensation and an obvious convergence. In this study, a hybrid Smith predictor and phase lead compensation approach is proposed. The hybrid Smith predictor and phase lead compensation can achieve a higher simulation fidelity with a little convergence. The phase angle of the compensator is analyzed and the stability condition of the HIL simulation system is given. The effectiveness of the proposed compensation approach is tested by simulations on an undamped elastic contact process.

  2. Disseminated intravascular coagulation (DIC)

    Science.gov (United States)

    ... Jr, Silberstein LE, et al, eds. Hematology: Basic Principles and Practice . 6th ed. Philadelphia, PA: Elsevier Saunders; 2013:chap 141. Thachil J, Toh CH. Current concepts in the management of disseminated intravascular coagulation. Thromb Res . 2012;129 ...

  3. Coagulation and inflammation

    NARCIS (Netherlands)

    van der Poll, T.

    2001-01-01

    Severe infection induces both activation of the coagulation system and multiple other inflammatory mediator cascades. This concise review summarizes the current knowledge of mechanisms that are considered to contribute to the procoagulant response to sepsis. Furthermore, evidence is discussed that

  4. Coagulation and Mental Disorders

    Directory of Open Access Journals (Sweden)

    Silvia Hoirisch-Clapauch

    2014-10-01

    Full Text Available The neurovascular unit is a key player in brain development, homeostasis, and pathology. Mental stress affects coagulation, while severe mental illnesses, such as recurrent depression and schizophrenia, are associated with an increased thrombotic risk and cardiovascular morbidity. Evidence indicates that the hemostatic system is involved to some extent in the pathogenesis, morbidity, and prognosis of a wide variety of psychiatric disorders. The current review focuses on emerging data linking coagulation and some psychiatric disorders.

  5. Contact size scaling of a W-contact phase-change memory cell based on numerical simulation

    International Nuclear Information System (INIS)

    Wei Yiqun; Lin Xinnan; Jia Yuchao; Cui Xiaole; Zhang Xing; Song Zhitang

    2012-01-01

    In the design of phase-change memory (PCM), it is important to perform numerical simulations to predict the performances of different device structures. This work presents a numerical simulation using a coupled system including Poisson's equation, the current continuity equation, the thermal conductivity equation, and phase-change dynamics to simulate the thermal and electric characteristics of phase-change memory. This method discriminates the common numerical simulation of PCM cells, from which it applies Possion's equation and current continuity equations instead of the Laplace equation to depict the electric characteristics of PCM cells, which is more adoptable for the semiconductor characteristics of phase-change materials. The results show that the simulation agrees with the measurement, and the scalability of PCM is predicted.

  6. Coagulation chemistries for silica removal from cooling tower water.

    Energy Technology Data Exchange (ETDEWEB)

    Nyman, May Devan; Altman, Susan Jeanne; Stewart, Tom

    2010-02-01

    The formation of silica scale is a problem for thermoelectric power generating facilities, and this study investigated the potential for removal of silica by means of chemical coagulation from source water before it is subjected to mineral concentration in cooling towers. In Phase I, a screening of many typical as well as novel coagulants was carried out using concentrated cooling tower water, with and without flocculation aids, at concentrations typical for water purification with limited results. In Phase II, it was decided that treatment of source or make up water was more appropriate, and that higher dosing with coagulants delivered promising results. In fact, the less exotic coagulants proved to be more efficacious for reasons not yet fully determined. Some analysis was made of the molecular nature of the precipitated floc, which may aid in process improvements. In Phase III, more detailed study of process conditions for aluminum chloride coagulation was undertaken. Lime-soda water softening and the precipitation of magnesium hydroxide were shown to be too limited in terms of effectiveness, speed, and energy consumption to be considered further for the present application. In Phase IV, sodium aluminate emerged as an effective coagulant for silica, and the most attractive of those tested to date because of its availability, ease of use, and low requirement for additional chemicals. Some process optimization was performed for coagulant concentration and operational pH. It is concluded that silica coagulation with simple aluminum-based agents is effective, simple, and compatible with other industrial processes.

  7. Convective heat transfer measurements in a vapour-liquid-liquid three-phase direct contact heat exchanger

    Science.gov (United States)

    Mahood, Hameed B.; Campbell, A. N.; Baqir, Ali Sh.; Sharif, A. O.; Thorpe, R. B.

    2017-12-01

    Energy usage is increasing around the world due to the continued development of technology, and population growth. Solar energy is a promising low-grade energy resource that can be harvested and utilised in different applications, such solar heater systems, which are used in both domestic and industrial settings. However, the implementation of an efficient energy conversion system or heat exchanger would enhance such low-grade energy processes. The direct contact heat exchanger could be the right choice due to its ability to efficiently transfer significant amounts of heat, simple design, and low cost. In this work, the heat transfer associated with the direct contact condensation of pentane vapour bubbles in a three-phase direct contact condenser is investigated experimentally. Such a condenser could be used in a cycle with a solar water heater and heat recovery systems. The experiments on the steady state operation of the three-phase direct contact condenser were carried out using a short Perspex tube of 70 cm in total height and an internal diameter of 4 cm. Only a height of 48 cm was active as the direct contact condenser. Pentane vapour, (the dispersed phase) with three different initial temperatures (40° C, 43.5° C and 47.5° C) was directly contacted with water (the continuous phase) at 19° C. The experimental results showed that the total heat transfer rate per unit volume along the direct contact condenser gradually decreased upon moving higher up the condenser. Additionally, the heat transfer rate increases with increasing mass flow rate ratio, but no significant effect on the heat transfer rate of varying the initial temperature of the dispersed phase was seen. Furthermore, both the outlet temperature of the continuous phase and the void fraction were positively correlated with the total heat transfer rate per unit volume, with no considerable effect of the initial temperature difference between the dispersed and continuous phases.

  8. Convective heat transfer measurements in a vapour-liquid-liquid three-phase direct contact heat exchanger

    Science.gov (United States)

    Mahood, Hameed B.; Campbell, A. N.; Baqir, Ali Sh.; Sharif, A. O.; Thorpe, R. B.

    2018-06-01

    Energy usage is increasing around the world due to the continued development of technology, and population growth. Solar energy is a promising low-grade energy resource that can be harvested and utilised in different applications, such solar heater systems, which are used in both domestic and industrial settings. However, the implementation of an efficient energy conversion system or heat exchanger would enhance such low-grade energy processes. The direct contact heat exchanger could be the right choice due to its ability to efficiently transfer significant amounts of heat, simple design, and low cost. In this work, the heat transfer associated with the direct contact condensation of pentane vapour bubbles in a three-phase direct contact condenser is investigated experimentally. Such a condenser could be used in a cycle with a solar water heater and heat recovery systems. The experiments on the steady state operation of the three-phase direct contact condenser were carried out using a short Perspex tube of 70 cm in total height and an internal diameter of 4 cm. Only a height of 48 cm was active as the direct contact condenser. Pentane vapour, (the dispersed phase) with three different initial temperatures (40° C, 43.5° C and 47.5° C) was directly contacted with water (the continuous phase) at 19° C. The experimental results showed that the total heat transfer rate per unit volume along the direct contact condenser gradually decreased upon moving higher up the condenser. Additionally, the heat transfer rate increases with increasing mass flow rate ratio, but no significant effect on the heat transfer rate of varying the initial temperature of the dispersed phase was seen. Furthermore, both the outlet temperature of the continuous phase and the void fraction were positively correlated with the total heat transfer rate per unit volume, with no considerable effect of the initial temperature difference between the dispersed and continuous phases.

  9. POLYELECTROLYTE MULTILAYER STAMPING IN AQUEOUS PHASE AND NON-CONTACT MODE

    Science.gov (United States)

    Mehrotra, Sumit; Lee, Ilsoon; Liu, Chun; Chan, Christina

    2011-01-01

    Polyelectrolyte multilayer (PEM) transfer printing has been previously achieved by stamping under dry conditions. Here, we show for the first time, that PEM can be transferred from a stamp to the base substrate under aqueous conditions whereby the two surfaces are in a non-contact mode. Degradable multilayers of (PAA/PEG)10.5 followed by non-degradable multilayers of (PDAC/SPS)80.5 were fabricated under acidic pH conditions on either PDMS or glass (stamp), and subsequently transferred over top of another multilayer prepared on a different substrate (base substrate), with a spacing of ~ 200 μm between the stamping surface and the base substrate. This multilayer transfer was performed under physiological pH conditions. This process is referred to herein as non-contact, aqueous-phase multilayer (NAM) transfer. NAM transfer can be useful for applications such as fabricating three-dimensional (3-D) cellular scaffolds. We attempted to create a 3-D cellular scaffold using NAM transfer, and characterized the scaffolds with conventional and fluorescence microscopy. PMID:21860540

  10. A gradient stable scheme for a phase field model for the moving contact line problem

    KAUST Repository

    Gao, Min

    2012-02-01

    In this paper, an efficient numerical scheme is designed for a phase field model for the moving contact line problem, which consists of a coupled system of the Cahn-Hilliard and Navier-Stokes equations with the generalized Navier boundary condition [1,2,4]. The nonlinear version of the scheme is semi-implicit in time and is based on a convex splitting of the Cahn-Hilliard free energy (including the boundary energy) together with a projection method for the Navier-Stokes equations. We show, under certain conditions, the scheme has the total energy decaying property and is unconditionally stable. The linearized scheme is easy to implement and introduces only mild CFL time constraint. Numerical tests are carried out to verify the accuracy and stability of the scheme. The behavior of the solution near the contact line is examined. It is verified that, when the interface intersects with the boundary, the consistent splitting scheme [21,22] for the Navier Stokes equations has the better accuracy for pressure. © 2011 Elsevier Inc.

  11. Sliding three-phase contact line of printed droplets for single-crystal arrays

    International Nuclear Information System (INIS)

    Kuang, Minxuan; Wu, Lei; Li, Yifan; Gao, Meng; Zhang, Xingye; Jiang, Lei; Song, Yanlin

    2016-01-01

    Controlling the behaviours of printed droplets is an essential requirement for inkjet printing of delicate three-dimensional (3D) structures or high-resolution patterns. In this work, molecular deposition and crystallization are regulated by manipulating the three-phase contact line (TCL) behaviour of the printed droplets. The results show that oriented single-crystal arrays are fabricated based on the continuously sliding TCL. Owing to the sliding of the TCL on the substrate, the outward capillary flow within the evaporating droplet is suppressed and the molecules are brought to the centre of the droplet, resulting in the formation of a single crystal. This work provides a facile strategy for controlling the structures of printed units by manipulating the TCL of printed droplets, which is significant for realizing high-resolution patterns and delicate 3D structures. (paper)

  12. Experimental and Analytical Study of Lead-Bismuth-Water Direct Contact Boiling Two-Phase Flow

    Science.gov (United States)

    Novitrian; Dostal, Vaclav; Takahashi, Minoru

    The characteristics of lead-bismuth(Pb-Bi)-water boiling two-phase flow were investigated experimentally and analytically using a Pb-Bi-water direct contact boiling two-phase flow loop. Pb-Bi flow rates and void fraction were measured in a vertical circular tube at conditions of system pressure 7MPa, liquid metal temperature 460°C and injected water temperature 220°C. The drift-flux model with the assumption that bubble sizes were dependent on the fluid surface tension and the density ratio of Pb-Bi to steam-water mixture was chosen and modified by the best fit to the measured void fraction. Pb-Bi flow rates were analytically estimated using balance condition between buoyancy force and pressure losses, where the buoyancy force was calculated from void fraction estimated using the modified drift-flux model. The deviation of the analytical results of the flow rates from the experimental ones was less than 10%.

  13. Investigational drugs for coagulation disorders.

    Science.gov (United States)

    Mannucci, Pier Mannuccio; Mancuso, Maria Elisa

    2013-08-01

    The current standard treatment in persons with hemophilia (PWH) is prophylaxis, given intravenously twice or thrice weekly, which is associated with a non negligible burden on patients' quality of life. Therefore the main attempts aiming to improve the management of PWH are targeted towards the development of a new generation of coagulation factors endowed with properties facilitating prophylaxis and/or a better control of bleeding. This article summarizes the main results obtained so far in the development of new antihemophilic products, and emphasizes the formidable requirements imposed upon by regulatory agencies to get marketing authorization for new drugs, which make progress in this field difficult. Published literature on new molecules for replacement treatment in hemophilia A and B has been retrieved by using PubMed search and all ongoing clinical trials have been looked for online. New molecules are usually engineered to have a longer plasma half-life but also in some instances a higher potency. The prolongation of half-life may be obtained by using sustained release delivery vehicles, by chemical modification or by creating fusion proteins. Factors VIII, IX and VII have been variably modified in order to obtain improved coagulation products and results from Phase I/II studies are encouraging, particularly for factor IX. However, Phase III studies that should provide evidence on efficacy and effectiveness more cogent for clinical use are still ongoing and results are not yet available.

  14. Evaluation of Contact Heat Transfer Coefficient and Phase Transformation during Hot Stamping of a Hat-Type Part

    Science.gov (United States)

    Kim, Heung-Kyu; Lee, Seong Hyeon; Choi, Hyunjoo

    2015-01-01

    Using an inverse analysis technique, the heat transfer coefficient on the die-workpiece contact surface of a hot stamping process was evaluated as a power law function of contact pressure. This evaluation was to determine whether the heat transfer coefficient on the contact surface could be used for finite element analysis of the entire hot stamping process. By comparing results of the finite element analysis and experimental measurements of the phase transformation, an evaluation was performed to determine whether the obtained heat transfer coefficient function could provide reasonable finite element prediction for workpiece properties affected by the hot stamping process. PMID:28788046

  15. Blood coagulation factor VIII

    Indian Academy of Sciences (India)

    Factor VIII (FVIII) functions as a co-factor in the blood coagulation cascade for the proteolytic activation of factor X by factor IXa. Deficiency of FVIII causes hemophilia A, the most commonly inherited bleeding disorder. This review highlights current knowledge on selected aspects of FVIII in which both the scientist and the ...

  16. The contact angle of wetting of the solid phase of soil before and after chemical modification

    Directory of Open Access Journals (Sweden)

    Tyugai Zemfira

    2015-07-01

    Full Text Available Wettability of soil affects a wide variety of processes including infiltration, preferential flow and surface runoff. Wettability of surface is usually expressed in terms of contact angle (CA measurement. If the CA between liquid and solid surface is less than 90°, the surface is called hydrophilic, otherwise the surface is called hydrophobic. If the CA of water droplet on hydrophilic surface is in a range of 0-30° this surface is called superhydrophilic. In case of superhydrophobic surfaces the CA exceeds 150° that means that these surfaces are extremely difficult to wet. CA of wetting of mineral soil particles depends on the overlying organic and iron compounds. The object of study is a sample of the humus-accumulative horizon of typical chernozem (Kursk, Russia and two samples (horizons A1, B2 of red ferrallitic soils (Fr. Norfolk, NE Oceania. The soil samples were analyzed for organic carbon, forms of non-silicate iron and hydrophobic-hydrophilic composition of humic substances. CA of wetting was determined in the intact samples and after removal of organic matter (H2O2 treatment, amorphous and crystallized forms of iron. Static contact angles were determined with the sessile drop method using a digital goniometer (Drop Shape Analysis System, DSA100, Krüss GmbH, Hamburg, Germany. The contact angle was calculated by the Young–Laplace method (fitting of Young–Laplace equation to the drop shape. The measurements were repeated 10-15 times for every sample. Oxidation of organic matter (H2O2 treatment causes an increase in the values of CA of wetting (in chernozem from 9.3 to 28,0-29.5º, in ferrallitic soil from 18.0 − 27.3 to 22.4 − 33.4º. CA remained constant for chernozem and slightly decreased in the case of ferrallitic soil, when the removal of amorphous and crystallized forms of iron was performed on samples pretreated with H2O2. CA increase occurs after successive removal of nonsilicate forms of iron from soil samples of

  17. Effect of sonochemical synthesized TiO2 nanoparticles and coagulation bath temperature on morphology, thermal stability and pure water flux of asymmetric cellulose acetate membranes prepared via phase inversion method

    Directory of Open Access Journals (Sweden)

    Abedini Reza

    2012-01-01

    Full Text Available In this study, asymmetric pure CA and CA/ TiO2 composite membranes were prepared via phase inversion by dispersing TiO2 nanopaticles in the CA casting solutions induced by immersion precipitation in water coagulation bath. TiO2 nanoparticles, which were synthesized by the sonochemical method, were added into the casting solution with different concentrations. Effects of TiO2 nanoparticles concentration (0 wt. %, 5wt.%, 10wt.%, 15wt.%, 20wt.% and 25wt.% and coagulation bath temperature (CBT= 25°C, 50°C and 75°C on morphology, thermal stability and pure water flux (PWF of the prepared membranes were studied and discussed. Increasing TiO2 concentration in the casting solution film along with higher CBT resulted in increasing the membrane thickness, water content (WC, membrane porosity and pure water flux (PWF, also these changes facilitate macrovoids formation. Thermal gravimetric analysis (TGA shows that thermal stability of the composite membranes were improved by the addition of TiO2 nanopaticles. Also TGA results indicated that increasing CBT in each TiO2 concentration leads to the decreasing of decomposition temperature (Td of hybrid membranes.

  18. Effect of non-solvents used in the coagulation bath on morphology of PVDF membranes

    Directory of Open Access Journals (Sweden)

    Mônica Beatriz Thürmer

    2012-12-01

    Full Text Available The aim of this paper was to prepare a poly (vinylidene fluoride (PVDF membrane using different non-solvents in the coagulation bath for the phase inversion method. In order to increase the mechanical strength of membranes, facing the pressure of work, was used a macro-porous polyester support. The morphology and structure of the resulting membranes were evaluated by scanning electron microscopy, porosity measurements, water and 1-octanol uptake, contact angle, pure water flux, hydraulic permeability and hydraulic resistance. The morphology and pure water flux changed significantly using ethanol (symmetric membrane and/or water (asymmetric membrane as the non-solvent. The symmetric membrane presented a high hydrophobic surface (water contact angle ~136º and a higher pure water flux and porosity than the asymmetric membrane, which presented a lower hydrophobicity surface (water contact angle ~90º. The morphologies obtained suggest different applications.

  19. Lattice Boltzmann modeling of contact angle and its hysteresis in two-phase flow with large viscosity difference.

    Science.gov (United States)

    Liu, Haihu; Ju, Yaping; Wang, Ningning; Xi, Guang; Zhang, Yonghao

    2015-09-01

    Contact angle hysteresis is an important physical phenomenon omnipresent in nature and various industrial processes, but its effects are not considered in many existing multiphase flow simulations due to modeling complexity. In this work, a multiphase lattice Boltzmann method (LBM) is developed to simulate the contact-line dynamics with consideration of the contact angle hysteresis for a broad range of kinematic viscosity ratios. In this method, the immiscible two-phase flow is described by a color-fluid model, in which the multiple-relaxation-time collision operator is adopted to increase numerical stability and suppress unphysical spurious currents at the contact line. The contact angle hysteresis is introduced using the strategy proposed by Ding and Spelt [Ding and Spelt, J. Fluid Mech. 599, 341 (2008)JFLSA70022-112010.1017/S0022112008000190], and the geometrical wetting boundary condition is enforced to obtain the desired contact angle. This method is first validated by simulations of static contact angle and dynamic capillary intrusion process on ideal (smooth) surfaces. It is then used to simulate the dynamic behavior of a droplet on a nonideal (inhomogeneous) surface subject to a simple shear flow. When the droplet remains pinned on the surface due to hysteresis, the steady interface shapes of the droplet quantitatively agree well with the previous numerical results. Four typical motion modes of contact points, as observed in a recent study, are qualitatively reproduced with varying advancing and receding contact angles. The viscosity ratio is found to have a notable impact on the droplet deformation, breakup, and hysteresis behavior. Finally, this method is extended to simulate the droplet breakup in a microfluidic T junction, with one half of the wall surface ideal and the other half nonideal. Due to the contact angle hysteresis, the droplet asymmetrically breaks up into two daughter droplets with the smaller one in the nonideal branch channel, and the

  20. Lead-germanium ohmic contact on to gallium arsenide formed by the solid phase epitaxy of germanium: A microstructure study

    Science.gov (United States)

    Radulescu, Fabian

    2000-12-01

    Driven by the remarkable growth in the telecommunication market, the demand for more complex GaAs circuitry continued to increase in the last decade. As a result, the GaAs industry is faced with new challenges in its efforts to fabricate devices with smaller dimensions that would permit higher integration levels. One of the limiting factors is the ohmic contact metallurgy of the metal semiconductor field effect transistor (MESFET), which, during annealing, induces a high degree of lateral diffusion into the substrate. Because of its limited reaction with the substrate, the Pd-Ge contact seems to be the most promising candidate to be used in the next generation of MESFET's. The Pd-Ge system belongs to a new class of ohmic contacts to compound semiconductors, part of an alloying strategy developed only recently, which relies on solid phase epitaxy (SPE) and solid phase regrowth to "un-pin" the Fermi level at the surface of the compound semiconductor. However, implementing this alloy into an integrated process flow proved to be difficult due to our incomplete understanding of the microstructure evolution during annealing and its implications on the electrical properties of the contact. The microstructure evolution and the corresponding solid state reactions that take place during annealing of the Pd-Ge thin films on to GaAs were studied in connection with their effects on the electrical properties of the ohmic contact. The phase transformations sequence, transition temperatures and activation energies were determined by combining differential scanning calorimetry (DSC) for thermal analysis with transmission electron microscopy (TEM) for microstructure identification. In-situ TEM annealing experiments on the Pd/Ge/Pd/GaAs ohmic contact system have permitted real time determination of the evolution of contact microstructure. The kinetics of the solid state reactions, which occur during ohmic contact formation, were determined by measuring the grain growth rates

  1. Overview of the coagulation system

    Directory of Open Access Journals (Sweden)

    Sanjeev Palta

    2014-01-01

    Full Text Available Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms ′coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same.

  2. Overview of the coagulation system.

    Science.gov (United States)

    Palta, Sanjeev; Saroa, Richa; Palta, Anshu

    2014-09-01

    Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms 'coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same.

  3. A comparison of Coulomb and pseudo-Coulomb friction implementations: Application to the table contact phase of gymnastics vaulting.

    Science.gov (United States)

    Jackson, M I; Hiley, M J; Yeadon, M R

    2011-10-13

    In the table contact phase of gymnastics vaulting both dynamic and static friction act. The purpose of this study was to develop a method of simulating Coulomb friction that incorporated both dynamic and static phases and to compare the results with those obtained using a pseudo-Coulomb implementation of friction when applied to the table contact phase of gymnastics vaulting. Kinematic data were obtained from an elite level gymnast performing handspring straight somersault vaults using a Vicon optoelectronic motion capture system. An angle-driven computer model of vaulting that simulated the interaction between a seven segment gymnast and a single segment vaulting table during the table contact phase of the vault was developed. Both dynamic and static friction were incorporated within the model by switching between two implementations of the tangential frictional force. Two vaulting trials were used to determine the model parameters using a genetic algorithm to match simulations to recorded performances. A third independent trial was used to evaluate the model and close agreement was found between the simulation and the recorded performance with an overall difference of 13.5%. The two-state simulation model was found to be capable of replicating performance at take-off and also of replicating key contact phase features such as the normal and tangential motion of the hands. The results of the two-state model were compared to those using a pseudo-Coulomb friction implementation within the simulation model. The two-state model achieved similar overall results to those of the pseudo-Coulomb model but obtained solutions more rapidly. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. INNOVATIVE NON-CONTACT METROLOGY SOLUTIONS FOR LARGE OPTICAL TELESCOPES, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA has unique non-contact precision metrology requirements for dimensionally inspecting the global position and orientation of large and highly-polished...

  5. ChemCam-like Spectrometer for Non-Contact Measurements of Key Isotopes, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This project addresses the need for a non-contact instrument capable of measuring the isotopic ratios O-18/O-16 and D/H from water ice and other solid materials...

  6. Contact line motion in confined liquid–gas systems: Slip versus phase transition

    KAUST Repository

    Xu, Xinpeng; Qian, Tiezheng

    2010-01-01

    -slip boundary condition, as the latter leads to a nonintegrable stress singularity. Recently, various diffuse-interface models have been proposed to explain the contact line motion using mechanisms missing from the sharp-interface treatments in fluid mechanics

  7. Phase-coherent electron transport through metallic atomic-sized contacts and organic molecules

    Energy Technology Data Exchange (ETDEWEB)

    Pauly, F.

    2007-02-02

    This work is concerned with the theoretical description of systems at the nanoscale, in particular the electric current through atomic-sized metallic contacts and organic molecules. In the first part, the characteristic peak structure in conductance histograms of different metals is analyzed within a tight-binding model. In the second part, an ab-initio method for quantum transport is developed and applied to single-atom and single-molecule contacts. (orig.)

  8. Non-contact Measurement of Remaining Thickness of Corroding Superheater Tubes. Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    Borggreen, Kjeld; Storesund, Jan

    2006-10-15

    Corrosion of superheaters has become a severe problem in many biomass boilers and incineration plants. This new situation calls for frequent tube wall thickness testing of the superheaters during very short shut-downs. To meet this demand Electro Magnetic Acoustic Transducer (EMAT) candidates as substitute for conventional manually operated contact UT-transducers. The EMAT can contactlessly generate an ultrasonic wave in the interphase between the external oxide and the metal. This means that measurements can be undertaken much quicker and with a much higher coverage simultaneously, without preceding blast operations. It is the aim of the project to demonstrate the usefulness of two simple EMAT systems, Panametrics and Sonatest, for fast and reliable tube thickness inspections in difficult-to-access superheater sections. The present Phase 1 of the project involves testing of the performance of the two systems in laboratory with the following results: 1. Both instruments work well on plate, tube, and pipe samples assuming the presence of an external oxide layer formed at a temperature above approximately 400 deg C. 2. Both instruments work well on all types of ferritic and martensitic steels but not on austenitic steels. 3. Both instruments work well independent of the thickness of the active oxide layer. 4. Both instruments work well independent of tube diameter, wall thickness, and sample width. 5. Both instruments work well over a very large range of wall thicknesses. Minimum tube wall thickness is less than 1.8 mm. 6. The tolerable lift-off (free distance between transducer and tube surface) is 2.4 - 3.0 mm for Panametrics system and 3.6 - 4.8 mm for Sonatest's system. The tolerable lift-off is a measure of the thickness of ash deposits, which can be tolerated on the tube surface as well as the misplacement, which can be tolerated in case of remote tube testing. 7. The tolerable off-set between tube axis and probe axis is very large for both instruments (10

  9. Non-contact Measurement of Remaining Thickness of Corroding Superheater Tubes. Phase 2

    Energy Technology Data Exchange (ETDEWEB)

    Borggreen, Kjeld; Storesund, Jan

    2007-12-15

    The Electro Magnetic Acoustic Transducer (EMAT) is a contactless thickness gauge for detection of corrosion on superheater tubes; it candidates as substitute for conventional manually operated contact UT transducers. It is the aim of the project to demonstrate the usefulness of two simple EMAT systems, Panametrics and Sonatest, for fast and reliable tube thickness inspections in difficult-to-access superheater sections. The present Phase 2 of the project involves testing of the systems on real compact superheaters in remote operation with the help of a mechanical manipulator designed and built for the purpose. The results are the following: - Both EMAT systems work well when tested in the field during handheld operation on tubes with a moderate thick layer of corrosion products and ash. The practical obtainable speed of cross-panel inspection of easily accessible panels is approximately 6 tubes per minute (6 thickness readings per minute). - The Sonatest system works well when tested in the field during remote operation on heavily corroded superheater tubes with thick ash layer. The Panametrics system was not found suitable for this type of field work. - The mechanical manipulator works well for cross-panel inspection of difficult-to-access superheater sections independent of the tube dimensions and the free space between the panels. In its present design it needs few improvements. - The practical obtainable speed of cross-panel inspection is 3 tubes per minute (3 thickness readings per minute). This speed is limited by the detection rate of the EMAT system and not by the travelling speed of the probe. - Scanning of tubes along their axis was never attempted, because the EMAT instruments were not capable of collecting data coming as a continuous stream. - It cannot be judged from visual alone and hardly from the service data, if a tube or a panel can be inspected by the magnetostrictive EMAT method or not. - The main contribution to failure of the EMAT inspection

  10. COAGULATION ACTIVITY IN LIVER DISEASE

    Directory of Open Access Journals (Sweden)

    Dr. Sheikh Sajjadieh Mohammad Reza

    2009-07-01

    Full Text Available Patients with advanced hepatic failure may present with the entire spectrum of coagulation factor deficiencies. This study was designed to determine laboratory abnormalities in coagulation in chronic liver disease and the association of these abnormalities with the extent of chronic hepatitis and cirrhosis. Coagulation markers were assayed in 60 participants: 20 patients with chronic hepatitis, 20 patients with cirrhosis, and 20 healthy individuals (control. Plasma levels of anti-thrombin III were determined by a chromogenic substrate method, and plasma concentrations of fibrinogen were analyzed by the Rutberg method. Commercially available assays were used for laboratory coagulation tests. The levels of coagualation activity markers in patients with chronic liver disease were significantly different in comparison to those in healthy participants. These results indicate the utility of measuring markers for coagulation activity in determining which cirrhosis patients are more susceptible to disseminated intravascular coagulation.

  11. Gaz Phase IR and UV Spectroscopy of Neutral Contact Ion Pairs

    Science.gov (United States)

    Habka, Sana; Brenner, Valerie; Mons, Michel; Gloaguen, Eric

    2016-06-01

    Cations and anions, in solution, tend to pair up forming ion pairs. They play a crucial role in many fundamental processes in ion-concentrated solutions and living organisms. Despite their importance and vast applications in physics, chemistry and biochemistry, they remain difficult to characterize namely because of the coexistence of several types of pairing in solution. However, an interesting alternative consists in applying highly selective gas phase spectroscopy which can offer new insights on these neutral ion pairs. Our study consists in characterizing contact ion pairs (CIPs) in isolated model systems (M+, Ph-(CH2)n-COO- with M=Li, Na, K, Rb, Cs, and n=1-3), to determine their spectral signatures and compare them to ion pairs in solution. We have used laser desorption to vaporize a solid tablet containing the desired salt. Structural information for each system was obtained by mass-selective, UV and IR laser spectroscopy combined with high level quantum chemistry calculations1. Evidence of the presence of neutral CIPs was found by scanning the π-π* transition of the phenyl ring using resonant two-photon ionization (R2PI). Then, conformational selective IR/UV double resonance spectra were recorded in the CO2- stretch region for each conformation detected. The good agreement between theoretical data obtained at the BSSE-corrected-fullCCSD(T)/dhf-TZVPP//B97-D3/dhf-TZVPP level and experimental IR spectra led us to assign the 3D structure for each ion pair formed. Spectral signatures of (M+, Ph-CH2-COO-) pairs, were assigned to a bidentate CIPs between the alkali cation and the carboxylate group. In the case of (Li+, Ph-(CH2)3-COO-) pairs, the presence of a flexible side chain promotes a cation-π interaction leading to a tridentate O-O-π structure with its unique IR and UV signatures. IR spectra obtained on isolated CIPs were found very much alike the ones published on lithium and sodium acetate in solution2. However, in the case of sodium acetate, solution

  12. Determination of the mass-transfer coefficient in liquid phase in a stream-bubble contact device

    Science.gov (United States)

    Dmitriev, A. V.; Dmitrieva, O. S.; Madyshev, I. N.

    2016-09-01

    One of the most effective energy saving technologies is the improvement of existing heat and mass exchange units. A stream-bubble contact device is designed to enhance the operation efficiency of heat and mass exchange units. The stages of the stream-bubble units that are proposed by the authors for the decarbonization process comprise contact devices with equivalent sizes, whose number is determined by the required performance of a unit. This approach to the structural design eliminates the problems that arise upon the transition from laboratory samples to industrial facilities and makes it possible to design the units of any required performance without a decrease in the effectiveness of mass exchange. To choose the optimal design that provides the maximum effectiveness of the mass-exchange processes in units and their intensification, the change of the mass-transfer coefficient is analyzed with the assumption of a number of parameters. The results of the study of the effect of various structural parameters of a stream-bubble contact device on the mass-transfer coefficient in the liquid phase are given. It is proven that the mass-transfer coefficient increases in the liquid phase, in the first place, with the growth of the level of liquid in the contact element, because the rate of the liquid run-off grows in this case and, consequently, the time of surface renewal is reduced; in the second place, with an increase in the slot diameter in the downpipe, because the jet diameter and, accordingly, their section perimeter and the area of the surface that is immersed in liquid increase; and, in the third place, with an increase in the number of slots in the downpipe, because the area of the surface that is immersed in the liquid of the contact element increases. Thus, in order to increase the mass-transfer coefficient in the liquid phase, it is necessary to design the contact elements with a minimum width and a large number of slots and their increased diameter; in

  13. Stability of Naturally Relevant Ternary Phases in the Cu–Sn–S system in Contact with an Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Andrea Giaccherini

    2016-07-01

    Full Text Available A relevant research effort is devoted to the synthesis and characterization of phases belonging to the ternary system Cu–Sn–S, mainly for their possible applications in semiconductor technology. Among all ternary phases, kuramite, Cu3SnS4, mohite, Cu2SnS3, and Cu4Sn7S16 have attracted the highest interest. Numerous studies were carried out claiming for the description of new phases in the ternary compositional field. In this study, we revise the existing literature on this ternary system, with a special focus on the phases stable in a temperature range at 25 °C. The only two ternary phases observed in nature are mohite and kuramite. Their occurrence is described as very rare. A numerical modelling of the stable solid phases in contact with a water solution was underwent to define stability relationships of the relevant phases of the system. The numerical modelling of the Eh-pH diagrams was carried out through the phreeqc software with the lnll.dat thermodynamic database. Owing to the complexity of this task, the subsystems Cu–O–H, Sn–O–H, Cu–S–O–H and Sn–S–O–H were firstly considered. The first Pourbaix diagram for the two naturally relevant ternary phases is then proposed.

  14. Colloids removal from water resources using natural coagulant: Acacia auriculiformis

    Science.gov (United States)

    Abdullah, M.; Roslan, A.; Kamarulzaman, M. F. H.; Erat, M. M.

    2017-09-01

    All waters, especially surface waters contain dissolved, suspended particles and/or inorganic matter, as well as several biological organisms, such as bacteria, algae or viruses. This material must be removed because it can affect the water quality that can cause turbidity and colour. The objective of this study is to develop water treatment process from Seri Alam (Johor, Malaysia) lake water resources by using natural coagulant Acacia auriculiformis pods through a jar test experiment. Jar test is designed to show the effectiveness of the water treatment. This process is a laboratory procedure that will simulate coagulation/flocculation with several parameters selected namely contact time, coagulant dosage and agitation speed. The most optimum percentage of colloids removal for each parameter is determined at 0.2 g, 90 min and 80 rpm. FESEM (Field-emission Scanning Electron Microscope) observed the small structures of final floc particles for optimum parameter in this study to show that the colloids coagulated the coagulant. All result showed that the Acacia auriculiformis pods can be a very efficient coagulant in removing colloids from water.

  15. Blood coagulation in hemophilia A and hemophilia C

    NARCIS (Netherlands)

    Cawthern, K. M.; van 't Veer, C.; Lock, J. B.; DiLorenzo, M. E.; Branda, R. F.; Mann, K. G.

    1998-01-01

    Tissue factor (TF)-induced coagulation was compared in contact pathway suppressed human blood from normal, factor VIII-deficient, and factor XI-deficient donors. The progress of the reaction was analyzed in quenched samples by immunoassay and immunoblotting for fibrinopeptide A (FPA),

  16. Trauma and Coagulation

    Directory of Open Access Journals (Sweden)

    Murat Yılmaz

    2011-08-01

    Full Text Available Bleeding and coagulation disorders related to trauma are pathological processes which are frequently seen and increase mortality. For the purpose, trauma patients should be protected from hypoperfusion, hypothermia, acidosis and hemodilution which may aggravate the increase in physiological responses to trauma as anticoagulation and fibrinolysis. Performing damage control surgery and resuscitation and transfusion of adequate blood and blood products in terms of amount and content as stated in protocols may increase the rate of survival. Medical treatments augmenting fibrin formation (fibrinogen, desmopressin, factor VIIa or preventing fibrin degradation (tranexamic acid have been proposed in selected cases but the efficacy of these agents in trauma patients are not proven. (Journal of the Turkish Society Intensive Care 2011; 9:71-6

  17. Treatment of Textile Wastewaterby Adsorption and Coagulation

    Directory of Open Access Journals (Sweden)

    Himanshu Patel

    2010-01-01

    Full Text Available The composite of wastewater treatment was carried out using activated charcoal as adsorbent to remove COD, BOD, color in which various parameters like adsorbent dose, contact duration, temperature and agitator speed were considered. The adsorbent behavior can be explained on the basis of Freundlich and Langmuir adsorption isotherm model. Maximum removal (87.6, 81.0 and 90.0% of COD, BOD and color respectively was found at adsorbent dosage of 11 g/L. Also, the textile mill wastewater was treated with different doses of coagulants like alum, ferric sulphate and ferrous sulphate at constant contact duration (4 hours and room temperature (300 K. Percentage reduction (maximum corresponds to 80.2, 74.0 and 84.9% was obtained for removal of COD, BOD and color respectively.

  18. Self-Tuning Threshold Method for Real-Time Gait Phase Detection Based on Ground Contact Forces Using FSRs

    Directory of Open Access Journals (Sweden)

    Jing Tang

    2018-02-01

    Full Text Available This paper presents a novel methodology for detecting the gait phase of human walking on level ground. The previous threshold method (TM sets a threshold to divide the ground contact forces (GCFs into on-ground and off-ground states. However, the previous methods for gait phase detection demonstrate no adaptability to different people and different walking speeds. Therefore, this paper presents a self-tuning triple threshold algorithm (STTTA that calculates adjustable thresholds to adapt to human walking. Two force sensitive resistors (FSRs were placed on the ball and heel to measure GCFs. Three thresholds (i.e., high-threshold, middle-threshold andlow-threshold were used to search out the maximum and minimum GCFs for the self-adjustments of thresholds. The high-threshold was the main threshold used to divide the GCFs into on-ground and off-ground statuses. Then, the gait phases were obtained through the gait phase detection algorithm (GPDA, which provides the rules that determine calculations for STTTA. Finally, the STTTA reliability is determined by comparing the results between STTTA and Mariani method referenced as the timing analysis module (TAM and Lopez–Meyer methods. Experimental results show that the proposed method can be used to detect gait phases in real time and obtain high reliability when compared with the previous methods in the literature. In addition, the proposed method exhibits strong adaptability to different wearers walking at different walking speeds.

  19. An energy-based equilibrium contact angle boundary condition on jagged surfaces for phase-field methods.

    Science.gov (United States)

    Frank, Florian; Liu, Chen; Scanziani, Alessio; Alpak, Faruk O; Riviere, Beatrice

    2018-08-01

    We consider an energy-based boundary condition to impose an equilibrium wetting angle for the Cahn-Hilliard-Navier-Stokes phase-field model on voxel-set-type computational domains. These domains typically stem from μCT (micro computed tomography) imaging of porous rock and approximate a (on μm scale) smooth domain with a certain resolution. Planar surfaces that are perpendicular to the main axes are naturally approximated by a layer of voxels. However, planar surfaces in any other directions and curved surfaces yield a jagged/topologically rough surface approximation by voxels. For the standard Cahn-Hilliard formulation, where the contact angle between the diffuse interface and the domain boundary (fluid-solid interface/wall) is 90°, jagged surfaces have no impact on the contact angle. However, a prescribed contact angle smaller or larger than 90° on jagged voxel surfaces is amplified. As a remedy, we propose the introduction of surface energy correction factors for each fluid-solid voxel face that counterbalance the difference of the voxel-set surface area with the underlying smooth one. The discretization of the model equations is performed with the discontinuous Galerkin method. However, the presented semi-analytical approach of correcting the surface energy is equally applicable to other direct numerical methods such as finite elements, finite volumes, or finite differences, since the correction factors appear in the strong formulation of the model. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Blood coagulation factors as inflammatory mediators

    NARCIS (Netherlands)

    Schoenmakers, Saskia H. H. F.; Reitsma, Pieter H.; Spek, C. Arnold

    2005-01-01

    After the first observations about blood coagulation by Hippocrates, it took until the early 1900s before the classic theory of blood coagulation was presented. As more and more other coagulation factors were discovered, the four-factor coagulation scheme became more complex, but better understood,

  1. Cellular dynamics in the draining lymph nodes during sensitization and elicitation phases of contact hypersensitivity

    DEFF Research Database (Denmark)

    Larsen, Jeppe Madura; Geisler, Carsten; Nielsen, Martin Weiss

    2007-01-01

    BACKGROUND: The different role of various immunological effector cells in contact hypersensitivity (CHS) is receiving increased attention. During the past decade, the involvement of different cell types in CHS has been investigated by the use of antibody-induced depletion of specific subtypes...... of immunological cells and by studying knockout mice lacking one or more of these immunological cell populations. OBJECTIVES: To develop a method for studying the collective cellular dynamics of immune cells in the draining lymph nodes during CHS in intact animals. PATIENTS/METHODS: Mice were sensitized and....../or challenged with 2,4-dinitrofluorobenzene or oxazolone. Using multi-parameter flow cytometry we determined the proliferation, activation state, and absolute number of helper T cells, cytotoxic T cells, B cells, and natural killer cells in the draining lymph nodes. RESULTS: The presented method can be applied...

  2. Numerical modelling of single-phase flow in rough fractures with contacts

    Science.gov (United States)

    Olkiewicz, Piotr; Dabrowski, Marcin

    2017-04-01

    Fracture flow may dominate in rocks with low porosity and it can accompany both industrial and natural processes. Typical examples of such processes are natural flows in crystalline rocks and industrial flows in oil and gas production systems or hydraulic fracturing. Fracture flow provides an important mechanism for transporting mass and energy. The distribution of the apertures of fracture and contact area are the key parameters with regard to the fracture transmissivity. We use the method of correlated random fields [Mourzenko, 1996] to generate synthetic fracture geometry in 3D. The flow of an incompressible Newtonian viscous fluid in geological formation can be approximated by the Stokes, the Stokes-Brinkman or the Reynolds models. We use our own implementation of the finite element method based on MILAMIN [Dabrowski, 2008] to solve governing partial differential equation over domain. We compare the Stokes, the Stokes-Brinkamn and the Reynolds models for fracture flow based on systematic numerical simulations for a wide range of geometric parameters. Mismatch between the Reynolds and the Stokes models becomes significant with increasing fracture roughness or contact area. The Stokes-Brinkman model is more accurate than Reynolds models due to additional Laplacian term, which allows to fulfil no-slip boundary condition. We present condition when the Reynolds and the Stokes-Brinkman models are valid. In the last three decades many authors used the Reynolds equation for studying fracture flow because of its simplicity. We recommend using the Stokes-Brinkman model for fracture flow, which allows to fulfil no-slip boundary condition on asperities boundary and is more accurate for rough fractures than the Reynolds model.

  3. Computer Simulations of Contact Forces for Airbags with Different Folding Patterns During Deployment Phase

    Directory of Open Access Journals (Sweden)

    King H. Yang

    1995-01-01

    Full Text Available An explicit finite element method was used to study the neck load and the contact force between an occupant and an airbag during an out-of-position frontal automobile crash. Two different folding patterns and two different mounting angles of the airbag were simulated. For the four cases simulated, the occupant’s neck axial force ranged from 156 to 376% of the data obtained from in-position sled tests using the Hybrid III dummy. The neck shear force ranged from 87 to 229% and the neck flexion moment ranged from 68 to 127% of in-position experimental results. In both 300 mounting angle simulations, the neck axial forces were higher than that of the two simulations with 00 mounting angles, but the trend for the neck shear force was the opposite. Although the kinematics of the model appear reasonable, the numbers generated by the model must be reviewed with great caution because the model has not been fully validated.

  4. Scatterometry measurement of nested lines, dual space, and rectangular contact CD on phase-shift masks

    Science.gov (United States)

    Lee, Kyung M.; Yedur, Sanjay; Henrichs, Sven; Tavassoli, Malahat; Baik, Kiho

    2007-03-01

    Evaluation of lithography process or stepper involves very large quantity of CD measurements and measurement time. In this paper, we report on a application of Scatterometry based metrology for evaluation of binary photomask lithography. Measurements were made on mask level with ODP scatterometer then on wafer with CD-SEM. 4 to 1 scaling from mask to wafer means 60nm line on wafer translates to 240nm on mask, easily measurable on ODP. Calculation of scatterometer profile information was performed by a in-situ library-based analysis (5sec/site). We characterized the CD uniformity, linearity, and metal film thickness uniformity. Results show that linearity measured from fixed-pitch, varying line/space ratio targets show good correlation to top-down CD-SEM with R2 of more than 0.99. ODP-SEM correlation results for variable pitch shows that careful examination of scatterometer profile results in order to obtain better correlation to CD SEM, since both tools react differently to the target profile variation. ODP results show that global CD distribution is clearly measurable with less outliers compared to CD SEM data. This is thought to be due to 'averaging' effect of scatterometer. The data show that Scatterometry provides a nondestructive and faster mean of characterizing lithography stepper performanceprofiles. APSM 1st level (before Cr removal) 'dual-space' CDs and EPSM rectangular contacts were also measured with and results demonstrates that Scatterometer is capable of measuring these targets with reasonable correlation to SEM.

  5. Coagulation factor XI improves host defence during murine pneumonia-derived sepsis independent of factor XII activation

    NARCIS (Netherlands)

    Stroo, Ingrid; Zeerleder, Sacha; Ding, Chao; Luken, Brenda M.; Roelofs, Joris J. T. H.; de Boer, Onno J.; Meijers, Joost C. M.; Castellino, Francis J.; van 't Veer, Cornelis; van der Poll, Tom

    2017-01-01

    Bacterial pneumonia, the most common cause of sepsis, is associated with activation of coagulation. Factor XI (FXI), the key component of the intrinsic pathway, can be activated via factor XII (FXII), part of the contact system, or via thrombin. To determine whether intrinsic coagulation is involved

  6. 3D adaptive finite element method for a phase field model for the moving contact line problems

    KAUST Repository

    Shi, Yi

    2013-08-01

    In this paper, we propose an adaptive finite element method for simulating the moving contact line problems in three dimensions. The model that we used is the coupled Cahn-Hilliard Navier-Stokes equations with the generalized Navier boundary condition(GNBC) proposed in [18]. In our algorithm, to improve the efficiency of the simulation, we use the residual type adaptive finite element algorithm. It is well known that the phase variable decays much faster away from the interface than the velocity variables. There- fore we use an adaptive strategy that will take into account of such difference. Numerical experiments show that our algorithm is both efficient and reliable. © 2013 American Institute of Mathematical Sciences.

  7. Dust Coagulation in Infalling Protostellar Envelopes I. Compact Grains

    Science.gov (United States)

    Yorke, H.; Lin, D.; Suttner, G.

    1999-01-01

    Dust plays a key role in the optical, thermodynamic and gas dynamical behavior of collapsing molecular cores. Because of relative velocities of the individual dust grains, coagulation and shattering can modify the grain size distribution and -- due to corresponding changes in the medium's opacity significantly -- influence the evolution during early phases of star formation.

  8. An efficient scheme for a phase field model for the moving contact line problem with variable density and viscosity

    KAUST Repository

    Gao, Min

    2014-09-01

    In this paper, we develop an efficient numerical method for the two phase moving contact line problem with variable density, viscosity, and slip length. The physical model is based on a phase field approach, which consists of a coupled system of the Cahn-Hilliard and Navier-Stokes equations with the generalized Navier boundary condition [1,2,5]. To overcome the difficulties due to large density and viscosity ratio, the Navier-Stokes equations are solved by a splitting method based on a pressure Poisson equation [11], while the Cahn-Hilliard equation is solved by a convex splitting method. We show that the method is stable under certain conditions. The linearized schemes are easy to implement and introduce only mild CFL time constraint. Numerical tests are carried out to verify the accuracy, stability and efficiency of the schemes. The method allows us to simulate the interface problems with extremely small interface thickness. Three dimensional simulations are included to validate the efficiency of the method. © 2014 Elsevier Inc.

  9. An efficient scheme for a phase field model for the moving contact line problem with variable density and viscosity

    KAUST Repository

    Gao, Min; Wang, Xiao-Ping

    2014-01-01

    In this paper, we develop an efficient numerical method for the two phase moving contact line problem with variable density, viscosity, and slip length. The physical model is based on a phase field approach, which consists of a coupled system of the Cahn-Hilliard and Navier-Stokes equations with the generalized Navier boundary condition [1,2,5]. To overcome the difficulties due to large density and viscosity ratio, the Navier-Stokes equations are solved by a splitting method based on a pressure Poisson equation [11], while the Cahn-Hilliard equation is solved by a convex splitting method. We show that the method is stable under certain conditions. The linearized schemes are easy to implement and introduce only mild CFL time constraint. Numerical tests are carried out to verify the accuracy, stability and efficiency of the schemes. The method allows us to simulate the interface problems with extremely small interface thickness. Three dimensional simulations are included to validate the efficiency of the method. © 2014 Elsevier Inc.

  10. Data for chromosome contacts and matched transcription profiles at three cell cycle phases in the fission yeast

    Directory of Open Access Journals (Sweden)

    Ralph S. Grand

    2015-06-01

    Full Text Available The data described in this article pertains to Grand et al. (2014, “Chromosome conformation maps in fission yeast reveal cell cycle dependent sub nuclear structure” [1]. Temperature sensitive Schizosaccharomyces pombe cell division cycle (cdc mutants, which are induced by a shift in temperature to 36 °C, were chosen for the analysis of genome structure in the G1 phase, G2 phase and mitotic anaphase of the cell cycle. Chromatin and total RNA were isolated from the same cell culture following synchronization. Two biological replicates were analyzed for each condition. The global, three-dimensional organization of the chromosomes was captured at high resolution using Genome Conformation Capture (GCC. GCC libraries and RNA samples were sequenced using an Illumina Hi-Seq 2000 platform (Beijing Genomics Institute (China. DNA sequences were processed using the Topography suite v1.19 [2] to obtain chromosome contact frequency matrices. RNA sequences were processed using the Cufflinks pipeline [3] to measure gene transcript levels and how these varied between the conditions. All sequence data, processed GCC and transcriptome files are available under the Gene Expression Omnibus (GEO accession number GSE52287 (http://www.ncbi.nlm.nih.gov/geo/query/acc.cgi?acc=GSE52287.

  11. Real-time electrical impedimetric monitoring of blood coagulation process under temperature and hematocrit variations conducted in a microfluidic chip.

    Directory of Open Access Journals (Sweden)

    Kin Fong Lei

    Full Text Available Blood coagulation is an extremely complicated and dynamic physiological process. Monitoring of blood coagulation is essential to predict the risk of hemorrhage and thrombosis during cardiac surgical procedures. In this study, a high throughput microfluidic chip has been developed for the investigation of the blood coagulation process under temperature and hematocrit variations. Electrical impedance of the whole blood was continuously recorded by on-chip electrodes in contact with the blood sample during coagulation. Analysis of the impedance change of the blood was conducted to investigate the characteristics of blood coagulation process and the starting time of blood coagulation was defined. The study of blood coagulation time under temperature and hematocrit variations was shown a good agreement with results in the previous clinical reports. The electrical impedance measurement for the definition of blood coagulation process provides a fast and easy measurement technique. The microfluidic chip was shown to be a sensitive and promising device for monitoring blood coagulation process even in a variety of conditions. It is found valuable for the development of point-of-care coagulation testing devices that utilizes whole blood sample in microliter quantity.

  12. Blood coagulation and the risk of atherothrombosis: a complex relationship

    Directory of Open Access Journals (Sweden)

    van der Voort Danielle

    2004-12-01

    Full Text Available Abstract The principles of Virchov's triad appear to be operational in atherothrombosis or arterial thrombosis: local flow changes and particularly vacular wall damage are the main pathophysiological elements. Furthermore, alterations in arterial blood composition are also involved although the specific role and importance of blood coagulation is an ongoing matter of debate. In this review we provide support for the hypothesis that activated blood coagulation is an essential determinant of the risk of atherothrombotic complications. We distinguish two phases in atherosclerosis: In the first phase, atherosclerosis develops under influence of "classical" risk factors, i.e. both genetic and acquired forces. While fibrinogen/fibrin molecules participate in early plaque lesions, increased activity of systemic coagulation is of no major influence on the risk of arterial thrombosis, except in rare cases where a number of specific procoagulant forces collide. Despite the presence of tissue factor – factor VII complex it is unlikely that all fibrin in the atherosclerotic plaque is the direct result from local clotting activity. The dominant effect of coagulation in this phase is anticoagulant, i.e. thrombin enhances protein C activation through its binding to endothelial thrombomodulin. The second phase is characterized by advancing atherosclerosis, with greater impact of inflammation as indicated by an elevated level of plasma C-reactive protein, the result of increased production influenced by interleukin-6. Inflammation overwhelms protective anticoagulant forces, which in itself may have become less efficient due to down regulation of thrombomodulin and endothelial cell protein C receptor (EPCR expression. In this phase, the inflammatory drive leads to recurrent induction of tissue factor and assembly of catalytic complexes on aggregated cells and on microparticles, maintaining a certain level of thrombin production and fibrin formation. In advanced

  13. Study on direct-contact phase-change liquid immersion cooling dense-array solar cells under high concentration ratios

    International Nuclear Information System (INIS)

    Kang, Xue; Wang, Yiping; Huang, Qunwu; Cui, Yong; Shi, Xusheng; Sun, Yong

    2016-01-01

    Highlights: • Direct-contact phase-change liquid immersion cooling for solar cells was proposed. • A self-regulating system investigated the feasibility in temperature control. • Temperature was well controlled between 87.3 °C and 88.5 °C. • Surface heat transfer coefficient was up to 23.49 kW/(m"2·K) under 398.4×. • A model illustrated the interface function was the main reason to affect light. - Abstract: A new cooling method by directly immersing the solar cells into phase-change liquid was put forward to cool dense-array solar cells in high concentrating photovoltaic system. A self-running system was built to study the feasibility of temperature control and the effect of bubbles generated by ethanol phase change under concentration ratio ranged between 219.8× and 398.4×. The results show that the cooling system is self-regulating without consuming extra energy and ethanol flow rate reaches up to 180.6 kg/(s·m"2) under 398.4×. The temperature of solar cells distributes in the range between 87.3 °C and 88.5 °C, the surface heat transfer coefficient of electric heating plate is up to 23.49 kW/(m"2·K) under 398.4×. The bubble effect on electrical performance of triple-junction solar cells is reported and the results show that I_s_c and P_m_a_x decline 10.2% and 7.3%, respectively. A model based on bubble images illustrates that light loss at the interface between ethanol and bubble is the main reason to cut down the electrical performance.

  14. The interplay between platelets and coagulation

    NARCIS (Netherlands)

    Weeterings, C.

    2009-01-01

    Platelet activation and blood coagulation are two processes often studied separately, but which cannot be seen independently from each other. Platelets play a pivotal role in coagulation, not only by providing negatively charged phospholipids, but also in localizing the coagulation process from a

  15. Coagulants modulate the hypocholesterolemic effect of tofu ...

    African Journals Online (AJOL)

    hope&shola

    2006-02-02

    Feb 2, 2006 ... The recent increase in soymilk and tofu (coagulated soymilk) consumption especially in western countries is due to the recognition of the health benefits of soy foods. The amount and the type of coagulated biomolecules (such as isoflavones) vary with the type of coagulant, and this will inevitable alter their ...

  16. Postprandial triglycerides and blood coagulation.

    Science.gov (United States)

    Silveira, A

    2001-01-01

    Most of our lifetime we spend in the postprandial state. Postprandial triglyceridemia may represent a procoagulant state involving disturbances of both blood coagulation and fibrinolysis, in particular due to elevation of the plasma levels of activated factor VII (VIIa) and plasminogen activator inhibitor (PAI-1). Therefore, disturbances of the hemostatic system might, at least partly, account for by the link between hypertriglyceridemia and coronary heart disease (CHD). Factor VIIa is the first enzyme of the blood coagulation system and serves a priming function for triggering of the clotting cascade. The coagulant activity of factor VII (VIIc, total activity of factor VII in plasma) was identified as an independent predictor of myocardial infarction in initially healthy middle-aged men, and particularly of fatal coronary events, and both serum cholesterol and triglyceride concentrations correlated positively with the VIIc level. Addition of fat to diet has been consistently shown to cause a rapid conversion of the factor VII zymogen into its active form (VIIa) whereas the concentration of total protein is unaffected. Postprandial activation of factor VII is dependent on lipolytic activity and it is mainly supported by large triglyceride-rich lipoprotein of the VLDL class. Studies in vivo with specific coagulation factor-deficient patients indicate that factor IX is essential for the postprandial activation of factor VII. The basal generation of thrombin seems to be unaffected by increased plasma levels of VIIa. However, since VIIa-tissue factor complex is responsible for the initiation of the coagulation cascade, increased generation of VIIa in the postprandial state would increase the potential for thrombin production in the event of plaque rupture. Plasminogen activator inhibitor-1 (PAI-1) is the major physiological inhibitor of the plasminogen activators in the circulation and thereby the principal inhibitor of the fibrinolytic system. Postprandial

  17. A three-phase in-vitro system for studying Pseudomonas aeruginosa adhesion and biofilm formation upon hydrogel contact lenses

    Directory of Open Access Journals (Sweden)

    Kohlmann Thomas

    2010-11-01

    Full Text Available Abstract Background Pseudomonas aeruginosa is commonly associated with contact lens (CL -related eye infections, for which bacterial adhesion and biofilm formation upon hydrogel CLs is a specific risk factor. Whilst P. aeruginosa has been widely used as a model organism for initial biofilm formation on CLs, in-vitro models that closely reproduce in-vivo conditions have rarely been presented. Results In the current investigation, a novel in-vitro biofilm model for studying the adherence of P. aeruginosa to hydrogel CLs was established. Nutritional and interfacial conditions similar to those in the eye of a CL wearer were created through the involvement of a solid:liquid and a solid:air interface, shear forces and a complex artificial tear fluid. Bioburdens varied depending on the CL material and biofilm maturation occurred after 72 h incubation. Whilst a range of biofilm morphologies were visualised including dispersed and adherent bacterial cells, aggregates and colonies embedded in extracellular polymer substances (EPS, EPS fibres, mushroom-like formations, and crystalline structures, a compact and heterogeneous biofilm morphology predominated on all CL materials. Conclusions In order to better understand the process of biofilm formation on CLs and to test the efficacy of CL care solutions, representative in-vitro biofilm models are required. Here, we present a three-phase biofilm model that simulates the environment in the eye of a CL wearer and thus generates biofilms which resemble those commonly observed in-situ.

  18. Coagulation Status in Hidradenitis Suppurativa

    DEFF Research Database (Denmark)

    Miller, Iben Marie; Johansen, Maria Egede; Mogensen, Ulla B

    2015-01-01

    BACKGROUND: Chronic inflammatory diseases other than hidradenitis suppurativa (HS) have been associated with prothrombotic/hypercoagulable status. OBJECTIVE: To investigate a possible association between the chronic inflammatory skin disease HS and prothrombotic/hypercoagulable state. METHODS: We.......3432). CONCLUSION: We did not find an association between HS and prothrombotic/hypercoagulable status. Thus, thrombocytes may not be activated in HS. Furthermore, INR may not be affected in HS, suggesting that intrinsic and vitamin K-dependent coagulation factors appear unaffected....

  19. Spontaneous imbibition in fractal tortuous micro-nano pores considering dynamic contact angle and slip effect: phase portrait analysis and analytical solutions.

    Science.gov (United States)

    Li, Caoxiong; Shen, Yinghao; Ge, Hongkui; Zhang, Yanjun; Liu, Tao

    2018-03-02

    Shales have abundant micro-nano pores. Meanwhile, a considerable amount of fracturing liquid is imbibed spontaneously in the hydraulic fracturing process. The spontaneous imbibition in tortuous micro-nano pores is special to shale, and dynamic contact angle and slippage are two important characteristics. In this work, we mainly investigate spontaneous imbibition considering dynamic contact angle and slip effect in fractal tortuous capillaries. We introduce phase portrait analysis to analyse the dynamic state and stability of imbibition. Moreover, analytical solutions to the imbibition equation are derived under special situations, and the solutions are verified by published data. Finally, we discuss the influences of slip length, dynamic contact angle and gravity on spontaneous imbibition. The analysis shows that phase portrait is an ideal tool for analysing spontaneous imbibition because it can evaluate the process without solving the complex governing ordinary differential equations. Moreover, dynamic contact angle and slip effect play an important role in fluid imbibition in fractal tortuous capillaries. Neglecting slip effect in micro-nano pores apparently underestimates imbibition capability, and ignoring variations in contact angle causes inaccuracy in predicting imbibition speed at the initial stage of the process. Finally, gravity is one of the factors that control the stabilisation of the imbibition process.

  20. Expression of human blood coagulation factor XI: characterization of the defect in factor XI type III deficiency

    NARCIS (Netherlands)

    Meijers, J. C.; Davie, E. W.; Chung, D. W.

    1992-01-01

    Human factor XI (FXI) is a blood coagulation factor participating in the early phase of the intrinsic pathway of blood coagulation. It circulates in blood as a glycoprotein composed of two identical chains held together by a single disulfide bond between the fourth apple domains. FXI has been

  1. Modeling and simulations for molecular scale hydrodynamics of the moving contact line in immiscible two-phase flows

    KAUST Repository

    Qian, Tiezheng

    2009-10-29

    This paper starts with an introduction to the Onsager principle of minimum energy dissipation which governs the optimal paths of deviation and restoration to equilibrium. Then there is a review of the variational approach to moving contact line hydrodynamics. To demonstrate the validity of our continuum hydrodynamic model, numerical results from model calculations and molecular dynamics simulations are presented for immiscible Couette and Poiseuille flows past homogeneous solid surfaces, with remarkable overall agreement. Our continuum model is also used to study the contact line motion on surfaces patterned with stripes of different contact angles (i.e. surfaces of varying wettability). Continuum calculations predict the stick-slip motion for contact lines moving along these patterned surfaces, in quantitative agreement with molecular dynamics simulation results. This periodic motion is tunable through pattern period (geometry) and contrast in wetting property (chemistry). The consequence of stick-slip contact line motion on energy dissipation is discussed. © 2009 IOP Publishing Ltd.

  2. A Simple Approach to Characterize Gas-Aqueous Liquid Two-phase Flow Configuration Based on Discrete Solid-Liquid Contact Electrification.

    Science.gov (United States)

    Choi, Dongwhi; Lee, Donghyeon; Kim, Dong Sung

    2015-10-14

    In this study, we first suggest a simple approach to characterize configuration of gas-aqueous liquid two-phase flow based on discrete solid-liquid contact electrification, which is a newly defined concept as a sequential process of solid-liquid contact and successive detachment of the contact liquid from the solid surface. This approach exhibits several advantages such as simple operation, precise measurement, and cost-effectiveness. By using electric potential that is spontaneously generated by discrete solid-liquid contact electrification, the configurations of the gas-aqueous liquid two-phase flow such as size of a gas slug and flow rate are precisely characterized. According to the experimental and numerical analyses on parameters that affect electric potential, gas slugs have been verified to behave similarly to point electric charges when the measuring point of the electric potential is far enough from the gas slug. In addition, the configuration of the gas-aqueous liquid two-phase microfluidic system with multiple gas slugs is also characterized by using the presented approach. For a proof-of-concept demonstration of using the proposed approach in a self-triggered sensor, a gas slug detector with a counter system is developed to show its practicality and applicability.

  3. Removal of arsenic and iron removal from drinking water using coagulation and biological treatment.

    Science.gov (United States)

    Pramanik, Biplob Kumar; Pramanik, Sagor Kumar; Suja, Fatihah

    2016-02-01

    Effects of biological activated carbon (BAC), biological aerated filter (BAF), alum coagulation and Moringa oleifera coagulation were investigated to remove iron and arsenic contaminants from drinking water. At an initial dose of 5 mg/L, the removal efficiency for arsenic and iron was 63% and 58% respectively using alum, and 47% and 41% respectively using Moringa oleifera. The removal of both contaminants increased with the increase in coagulant dose and decrease in pH. Biological processes were more effective in removing these contaminants than coagulation. Compared to BAF, BAC gave greater removal of both arsenic and iron, removing 85% and 74%, respectively. Longer contact time for both processes could reduce the greater concentration of arsenic and iron contaminants. The addition of coagulation (at 5 mg/L dosage) and a biological process (with 15 or 60 min contact time) could significantly increase removal efficiency, and the maximum removal was observed for the combination of alum and BAC treatment (60 min contact time), with 100% and 98.56% for arsenic and iron respectively. The reduction efficiency of arsenic and iron reduced with the increase in the concentration of dissolved organics in the feedwater due to the adsorption competition between organic molecules and heavy metals.

  4. Modeling and simulations for molecular scale hydrodynamics of the moving contact line in immiscible two-phase flows

    KAUST Repository

    Qian, Tiezheng; Wu, Congmin; Lei, Siu Long; Wang, Xiao Ping; Sheng, Ping

    2009-01-01

    This paper starts with an introduction to the Onsager principle of minimum energy dissipation which governs the optimal paths of deviation and restoration to equilibrium. Then there is a review of the variational approach to moving contact line

  5. A fully discrete energy stable scheme for a phase filed moving contact line model with variable densities and viscosities

    KAUST Repository

    Zhu, Guangpu; Chen, Huangxin; Sun, Shuyu; Yao, Jun

    2018-01-01

    In this paper, a fully discrete scheme which considers temporal and spatial discretizations is presented for the coupled Cahn-Hilliard equation in conserved form with the dynamic contact line condition and the Navier-Stokes equation

  6. Robust Load Cell Cell for Discrete Contact Force Measurements of Sampling Systems and/or Instruments, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Bear Engineering proposes to develop a simple, robust, extreme environment compatible, mechanical load cell to enable the control of contact forces for placement of...

  7. Solid-Phase Contact Assay That Uses a lux-Marked Nitrosomonas europaea Reporter Strain To Estimate Toxicity of Bioavailable Linear Alkylbenzene Sulfonate in Soil

    OpenAIRE

    Brandt, Kristian K.; Pedersen, Anders; Sørensen, Jan

    2002-01-01

    Information about in situ toxicity of the bioavailable pools of adsorptive soil pollutants is a prerequisite for proper ecological risk assessment in contaminated soils. Such toxicity data may be obtained by assays allowing for direct exposure of introduced test microorganisms to the toxicants, as they appear in solid solution equilibria in the natural soil. We describe a novel sensitive solid-phase contact assay for in situ toxicity testing of soil pollutants based on a recombinant biolumine...

  8. Stick–slip boundary friction mode as a second-order phase transition with an inhomogeneous distribution of elastic stress in the contact area

    Directory of Open Access Journals (Sweden)

    Iakov A. Lyashenko

    2017-09-01

    Full Text Available This article presents an investigation of the dynamical contact between two atomically flat surfaces separated by an ultrathin lubricant film. Using a thermodynamic approach we describe the second-order phase transition between two structural states of the lubricant which leads to the stick–slip mode of boundary friction. An analytical description and numerical simulation with radial distributions of the order parameter, stress and strain were performed to investigate the spatial inhomogeneity. It is shown that in the case when the driving device is connected to the upper part of the friction block through an elastic spring, the frequency of the melting/solidification phase transitions increases with time.

  9. On the Size Dependence of Molar and Specific Properties of Independent Nano-phases and Those in Contact with Other Phases

    Science.gov (United States)

    Kaptay, George

    2018-05-01

    Nano-materials are materials with at least one nano-phase. A nano-phase is a phase with at least one of its dimensions below 100 nm. It is shown here that nano-phases have at least 1% of their atoms along their surface layer. The ratio of surface atoms is proportional to the specific surface area of the phase, defined as the ratio of its surface area to its volume. Each specific/molar property has its bulk value and its surface value for the given phase, being always different, as the energetic states of the atoms in the bulk and in the surface layer of a phase are different. The average specific/molar property of a nano-phase is modeled here as a linear combination of the bulk and surface values of the same property, scaled with the ratio of the surface atoms. That makes the performance of all nano-phases proportional to their specific surface area. As the characteristic size of the nano-phase is inversely proportional to its specific surface area, all specific/molar properties of nano-phases are inversely proportional to the characteristic size of the phase. This is applied to the size dependence of the molar Gibbs energy of the nano-phase, which appears to be in agreement with the thermodynamics of Gibbs. This agreement proves the general validity of the present model on the size dependence of the specific/molar properties of independent nano-phases. It is shown that the properties of nano-phases are different for independent nano-phases (surrounded only by their equilibrium vapor phase) and for nano-phases in multi-phase situations, such as a liquid nano-droplet in the sessile drop configuration.

  10. Are Cancer Patients' Socioeconomic and Cultural Factors Associated with Contact to General Practitioners in the Last Phase of Life?

    DEFF Research Database (Denmark)

    Neergaard, M A; Olesen, Frede; Sondergaard, J

    2015-01-01

    Introduction. General practitioners (GPs) play an important role in end of life care, which should be offered regardless of socioeconomic position and cultural factors. The aim was to analyse associations between GP contacts at the end of life and socioeconomic and cultural characteristics......' socioeconomic and cultural characteristics were calculated. Results. Having low income (RR: 1.18 (95% CI: 1.03; 1.35)) and being immigrants or descendants of immigrants (RR: 1.17 (95% CI: 1.02; 1.35)) were associated with GP face-to-face contacts. However, patients living in large municipalities had lower...

  11. Treatment of the oily produced water (OPW using coagulant mixtures

    Directory of Open Access Journals (Sweden)

    R. Hosny

    2016-09-01

    Full Text Available Treatment of the oily produced water (OPW before injection into oil reservoirs is necessary to reduce formation damage. This can be done using chemo-physical process to minimize the oil droplets in water. In this respect, this work aims to extract natural polymer (chitosan from shrimp shells and mix it with coagulants (chitosan/carboxy methyl cellulose and chitosan/aluminum sulfate to adsorb oil from OPW. Adsorption experiments were carried out in batch mode firstly to choose the best coagulants in water treatment, also to investigate the effects of pH on the adsorption uptake, adsorbent dosage, coagulant mixture doses and contact time. It was found that the oil removal by chitosan reached 96.35% and 59% at pH = 4 and pH = 9, respectively. The ability of chitosan to remove oil was increased after adding different coagulants CMC/or aluminum sulfate at average mixing time between 30 and 60 min. It was also found that the highest removal efficiency of chitosan/CMC is 99% at (90% chitosan: 10% CMC and chitosan/Al2(SO43 is 85% at (80% chitosan: 20% Al2(SO43. The SEM photographs of chitosan, chitosan/CMC and chitosan/Al2(SO43 mixture as oil removal showed that chitosan/Al2(SO43 lies between chitosan alone and chitosan/CMC mixture. Generally chitosan/CMC characterized significantly by its high ability to adsorb petroleum oil and suspended solids from OPW, additionally, reduces the economic cost of water treatment.

  12. Investigation of coagulation activity of natural coagulants from seeds of different leguminose species

    Directory of Open Access Journals (Sweden)

    Šćiban Marina B.

    2005-01-01

    Full Text Available The ability of seeds of plants: Phaseolus vulgaris, Robinia pseudoacacia Ceratonia siliqua and Amorpha fruticosa, to act as natural coagulants was tested using synthetic turbid water. This water was prepared by adding kaolin into tap water, just before the test. Active components were extracted from ground seeds with distilled water. The coagulation ability of this extract was assessed by the use of standard jar test measurements in water with various initial turbidity. Investigation of these natural coagulants was confirmed their positive coagulation activity. Of all plants that have been examined, the seed extract from Ceratonia siliqua appeared to be one of the most effective coagulants for water treatment. A dose of 20 mg/l of this coagulant resulted in 100% coagulation activity for clarification of water with 17.5 NTU initial turbidity.

  13. Influence of vegetable coagulant and ripening time on the lipolytic and sensory profile of cheeses made with raw goat milk from Canary breeds.

    Science.gov (United States)

    Rincón, Arturo A; Pino, Verónica; Fresno, María R; Jiménez-Abizanda, Ana I; Álvarez, Sergio; Ayala, Juan H; Afonso, Ana M

    2017-04-01

    Free fatty acids and sensory profiles were obtained for cheeses made with raw goat milk and vegetable coagulant, derived from the cardoon flower ( Cynara cardunculus), at different ripening times (7 and 20 days). A solid-liquid phase extraction method followed by solid-phase extraction and gas chromatography was used. Profiles were also obtained with cheeses made with commercial coagulant, traditional kid rennet paste, and mixture coagulant (vegetable coagulant-kid rennet). The use of vegetable coagulant and vegetable coagulant-kid rennet is common in traditional Protected Designation of Origin cheeses such as " Queso Flor de Guía" and " Queso Media Flor de Guía" (Spain). Contents of short-chain free fatty acids (7.5-22.5 mmol·kg -1 ), medium-chain free fatty acids (0.4-3.7 mmol·kg -1 ), and long-chain free fatty acids (0.2-2.1 mmol·kg -1 ) varied depending on the coagulant type and the ripening time. Vegetable coagulant cheeses present odour intensity and flavour intensity much higher than commercial coagulant cheeses in the sensory analysis for cheeses obtained with seven days of ripening, but the values decrease when increasing the ripening time. Multivariate analysis allowed us to differentiate cheese samples according to the ripening time when using lipolytic profile and according to the coagulant type using the sensory profile.

  14. Process of coagulating asphalts, etc

    Energy Technology Data Exchange (ETDEWEB)

    Schaeffer, J A; Pfersch, G

    1931-03-28

    The present invention has for its object a process of deasphaltizing and deparaffining applicable to mixtures of hydrocarbons such as crude mineral oils and tars obtained under the influence of heat from shales, lignites, peats, and similar products, to natural bitumens and those obtained by extraction with organic solvents and also all those derived from the substances, the process in question having the following characteristics: the coagulation or the precipitation of the asphaltic material, the resinous material, and the asphaltic and resinous material, which is found in the colloidal state or any other state in the substances given above, is obtained by the addition of a small amount of solvent and of acids or mixtures of acids.

  15. Non-Contact Sensor for Long-Term Continuous Vital Signs Monitoring: A Review on Intelligent Phased-Array Doppler Sensor Design.

    Science.gov (United States)

    Hall, Travis; Lie, Donald Y C; Nguyen, Tam Q; Mayeda, Jill C; Lie, Paul E; Lopez, Jerry; Banister, Ron E

    2017-11-15

    It has been the dream of many scientists and engineers to realize a non-contact remote sensing system that can perform continuous, accurate and long-term monitoring of human vital signs as we have seen in many Sci-Fi movies. Having an intelligible sensor system that can measure and record key vital signs (such as heart rates and respiration rates) remotely and continuously without touching the patients, for example, can be an invaluable tool for physicians who need to make rapid life-and-death decisions. Such a sensor system can also effectively help physicians and patients making better informed decisions when patients' long-term vital signs data is available. Therefore, there has been a lot of research activities on developing a non-contact sensor system that can monitor a patient's vital signs and quickly transmit the information to healthcare professionals. Doppler-based radio-frequency (RF) non-contact vital signs (NCVS) monitoring system are particularly attractive for long term vital signs monitoring because there are no wires, electrodes, wearable devices, nor any contact-based sensors involved so the subjects may not be even aware of the ubiquitous monitoring. In this paper, we will provide a brief review on some latest development on NCVS sensors and compare them against a few novel and intelligent phased-array Doppler-based RF NCVS biosensors we have built in our labs. Some of our NCVS sensor tests were performed within a clutter-free anechoic chamber to mitigate the environmental clutters, while most tests were conducted within the typical Herman-Miller type office cubicle setting to mimic a more practical monitoring environment. Additionally, we will show the measurement data to demonstrate the feasibility of long-term NCVS monitoring. The measured data strongly suggests that our latest phased array NCVS system should be able to perform long-term vital signs monitoring intelligently and robustly, especially for situations where the subject is sleeping

  16. Language Contact.

    Science.gov (United States)

    Nelde, Peter Hans

    1995-01-01

    Examines the phenomenon of language contact and recent trends in linguistic contact research, which focuses on language use, language users, and language spheres. Also discusses the role of linguistic and cultural conflicts in language contact situations. (13 references) (MDM)

  17. Measurement of the coagulation dynamics of bovine liver using the modified microscopic Beer-Lambert law.

    Science.gov (United States)

    Terenji, Albert; Willmann, Stefan; Osterholz, Jens; Hering, Peter; Schwarzmaier, Hans-Joachim

    2005-06-01

    During heating, the optical properties of biological tissues change with the coagulation state. In this study, we propose a technique, which uses these changes to monitor the coagulation process during laser-induced interstitial thermotherapy (LITT). Untreated and coagulated (water bath, temperatures between 35 degrees C and 90 degrees C for 20 minutes.) samples of bovine liver tissue were examined using a Nd:YAG (lambda = 1064 nm) frequency-domain reflectance spectrometer. We determined the time integrated intensities (I(DC)) and the phase shifts (Phi) of the photon density waves after migration through the tissue. From these measured quantities, the time of flight (TOF) of the photons and the absorption coefficients of the samples were derived using the modified microscopic Beer-Lambert law. The absorption coefficients of the liver samples decreased significantly with the temperature in the range between 50 degrees C and 70 degrees C. At the same time, the TOF of the investigated photos was found increased indicating an increased scattering. The coagulation dynamics could be well described using the Arrhenius formalism with the activation energy of 106 kJ/mol and the frequency factor of 1.59 x 10(13)/second. Frequency-domain reflectance spectroscopy in combination with the modified microscopic Beer-Lambert (MBL) is suitable to measure heat induced changes in the absorption and scattering properties of bovine liver in vitro. The technique may be used to monitor the coagulation dynamics during local thermo-coagulation in vivo. Copyright 2005 Wiley-Liss, Inc.

  18. Influential factors of formation kinetics of flocs produced by water treatment coagulants.

    Science.gov (United States)

    Wu, Chunde; Wang, Lin; Hu, Bing; Ye, Jian

    2013-05-01

    The growth rate and size of floc formation is of great importance in water treatment especially in coagulation process. The floc formation kinetics and the coagulation efficiency of synthetic water were investigated by using an on-line continuous optical photometric dispersion analyze and the analysis of water quality. Experimental conditions such as alum dosage, pH value for coagulation, stirring intensity and initial turbidity were extensively examined. The photometric dispersion analyze results showed that coagulation of kaolin suspensions with two coagulants (alum and polyaluminium chloride) could be taken as a two-phase process: slow and rapid growth periods. Operating conditions with higher coagulant doses, appropriate pH and average shear rate might be particularly advantageous. The rate of overall floc growth was mainly determined by a combination of hydraulic and water quality conditions such as pH and turbidity. The measurement of zeta potential indicates that polyaluminium chloride exhibited higher charge-neutralizing ability than alum and achieved lower turbidities than alum for equivalent Al dosages. Under the same operating conditions, the alum showed a higher grow rate, but with smaller floc size.

  19. Multipurpose HTS Coagulation Analysis: Assay Development and Assessment of Coagulopathic Snake Venoms

    Directory of Open Access Journals (Sweden)

    Kristina B. M. Still

    2017-11-01

    Full Text Available Coagulation assays currently employed are often low throughput, require specialized equipment and/or require large blood/plasma samples. This study describes the development, optimization and early application of a generic low-volume and high-throughput screening (HTS assay for coagulation activity. The assay is a time-course spectrophotometric measurement which kinetically measures the clotting profile of bovine or human plasma incubated with Ca2+ and a test compound. The HTS assay can be a valuable new tool for coagulation diagnostics in hospitals, for research in coagulation disorders, for drug discovery and for venom research. A major effect following envenomation by many venomous snakes is perturbation of blood coagulation caused by haemotoxic compounds present in the venom. These compounds, such as anticoagulants, are potential leads in drug discovery for cardiovascular diseases. The assay was implemented in an integrated analytical approach consisting of reversed-phase liquid chromatography (LC for separation of crude venom components in combination with parallel post-column coagulation screening and mass spectrometry (MS. The approach was applied for the rapid assessment and identification of profiles of haemotoxic compounds in snake venoms. Procoagulant and anticoagulant activities were correlated with accurate masses from the parallel MS measurements, facilitating the detection of peptides showing strong anticoagulant activity.

  20. Blood viscosity during coagulation at different shear rates

    Science.gov (United States)

    Ranucci, Marco; Laddomada, Tommaso; Ranucci, Matteo; Baryshnikova, Ekaterina

    2014-01-01

    Abstract During the coagulation process, blood changes from a liquid to a solid gel phase. These changes are reflected by changes in blood viscosity; however, blood viscosity at different shear rates (SR) has not been previously explored during the coagulation process. In this study, we investigated the viscosity changes of whole blood in 10 subjects with a normal coagulation profile, using a cone‐on‐plate viscosimeter. For each subject, three consecutive measurements were performed, at a SR of 20, 40, 80 sec−1. On the basis of the time‐dependent changes in blood viscosity, we identified the gel point (GP), the time‐to‐gel point (TGP), the maximum clot viscosity (MCV), and the clot lysis half‐time (CLH). The TGP significantly (P = 0.0023) shortened for increasing SR, and was significantly associated with the activated partial thromboplastin time at a SR of 20 sec−1 (P = 0.038) and 80 sec−1 (P = 0.019). The MCV was significantly lower at a SR of 80 sec−1 versus 40 sec−1 (P = 0.027) and the CLH significantly (P = 0.048) increased for increasing SR. These results demonstrate that measurement of blood viscosity during the coagulation process offers a number of potentially useful parameters. In particular, the association between the TGP and the activated partial thromboplastin time is an expression of the clotting time (intrinsic and common pathway), and its shortening for increasing SR may be interpreted the well‐known activating effects of SR on platelet activation and thrombin generation. Further studies focused on the TGP under conditions of hypo‐ or hypercoagulability are required to confirm its role in the clinical practice. PMID:24994896

  1. Noneczematous Contact Dermatitis

    Science.gov (United States)

    Foti, Caterina; Vestita, Michelangelo; Angelini, Gianni

    2013-01-01

    Irritant or allergic contact dermatitis usually presents as an eczematous process, clinically characterized by erythematoedematovesicous lesions with intense itching in the acute phase. Such manifestations become erythematous-scaly as the condition progresses to the subacute phase and papular-hyperkeratotic in the chronic phase. Not infrequently, however, contact dermatitis presents with noneczematous features. The reasons underlying this clinical polymorphism lie in the different noxae and contact modalities, as well as in the individual susceptibility and the various targeted cutaneous structures. The most represented forms of non-eczematous contact dermatitis include the erythema multiforme-like, the purpuric, the lichenoid, and the pigmented kinds. These clinical entities must obviously be discerned from the corresponding “pure” dermatitis, which are not associated with contact with exogenous agents. PMID:24109520

  2. Removal of congo red and methylene blue from waste water using coagulation

    International Nuclear Information System (INIS)

    Ghaffar, S.; Nosheen, S.; Ahmad, N.

    2011-01-01

    The textile industry has been condemned as being one of the world's worst offenders in terms of pollution Because of increasing population and industrial developments, a huge amount of wastewater is discharged to the environment above the level that the nature can eliminate. Many techniques like oxidation, reduction, physical treatment and biological method are available for removal of colored dyes from wastewater. The work presented here involved the decolorisation of wastewater containing congo red and methylene blue using various coagulants such as alum, bentonite and lime. The effect of various experimental factors such as dosage of coagulants, contact time between coagulant and dye and concentration of dyes and working environment like shaking and static was studied. Under static condition alum give almost 43% removal of congo red while with 10 minutes shaking 74 % removal of 80 dye was achieved with same coagulant. The highest removal of congo red was found to be 99.5 % by using alum after 30 minutes of shaking but in case of methylene blue it intensified the color and gave negative results. Lime gave only 33 % color removal of congo red under static conditions while 57% color was removed under shaking conditions. Maximum color removal achieved by lime was 89% at 40 minutes with shaking condition. Lime gave 60% removal of methylene blue in static condition and 90% removal in shaking condition and maximum absorbance at 80 ppm was 90%. Bentonite also used for the removal of methylene blue and gave 89% removal in shaking condition. By increasing shaking time %age removal increased to 100% at 40 min. And amount of coagulant increased the removal efficiency it attained 100% in both lime and bentonite coagulant for methylene blue Overall alum was found to be better coagulant for the removal of congo red from its aqueous solution. Lime and bentonite both proved better and economical for removal of methylene blue from aqueous solution at lab scale. (author)

  3. Automatic method for estimation of in situ effective contact angle from X-ray micro tomography images of two-phase flow in porous media.

    Science.gov (United States)

    Scanziani, Alessio; Singh, Kamaljit; Blunt, Martin J; Guadagnini, Alberto

    2017-06-15

    Multiphase flow in porous media is strongly influenced by the wettability of the system, which affects the arrangement of the interfaces of different phases residing in the pores. We present a method for estimating the effective contact angle, which quantifies the wettability and controls the local capillary pressure within the complex pore space of natural rock samples, based on the physical constraint of constant curvature of the interface between two fluids. This algorithm is able to extract a large number of measurements from a single rock core, resulting in a characteristic distribution of effective in situ contact angle for the system, that is modelled as a truncated Gaussian probability density distribution. The method is first validated on synthetic images, where the exact angle is known analytically; then the results obtained from measurements within the pore space of rock samples imaged at a resolution of a few microns are compared to direct manual assessment. Finally the method is applied to X-ray micro computed tomography (micro-CT) scans of two Ketton cores after waterflooding, that display water-wet and mixed-wet behaviour. The resulting distribution of in situ contact angles is characterized in terms of a mixture of truncated Gaussian densities. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  4. The influence of the spin-dependent phases of tunneling electrons on the conductance of a point ferromagnet/isolator/d-wave superconductor contact.

    Science.gov (United States)

    Vodopyanov, B P

    2010-05-12

    The influence of the spin-dependent phase shifts (SDPSs) associated with the electronic reflection and transmission amplitudes acquired by electrons upon scattering at the potential barrier on the Andreev reflection probability of electron and hole excitations for a ferromagnet/isolator/d-wave superconductor (FIS) contact and on the charge conductance of the FIS contact is studied. Various superconductor orientations are considered. It has been found that for strong ferromagnets and ultrathin interface potential for the {110} oriented d-wave superconductor the presence of the SDPS can lead to the appearance of finite-voltage peaks in the charge conductance of the F/I/d-wave superconductor contact. On the contrary, for the {100} orientation of the d-wave superconductor the presence of the SDPS can lead to restoration of the zero-voltage peak and suppression of finite-voltage peaks. The spin-dependent amplitudes of the Andreev reflection probability and energy levels of the spin-dependent Andreev bound states are found.

  5. Factor XI Deficiency Alters the Cytokine Response and Activation of Contact Proteases during Polymicrobial Sepsis in Mice.

    Directory of Open Access Journals (Sweden)

    Charles E Bane

    Full Text Available Sepsis, a systemic inflammatory response to infection, is often accompanied by abnormalities of blood coagulation. Prior work with a mouse model of sepsis induced by cecal ligation and puncture (CLP suggested that the protease factor XIa contributed to disseminated intravascular coagulation (DIC and to the cytokine response during sepsis. We investigated the importance of factor XI to cytokine and coagulation responses during the first 24 hours after CLP. Compared to wild type littermates, factor XI-deficient (FXI-/- mice had a survival advantage after CLP, with smaller increases in plasma levels of TNF-α and IL-10 and delayed IL-1β and IL-6 responses. Plasma levels of serum amyloid P, an acute phase protein, were increased in wild type mice 24 hours post-CLP, but not in FXI-/- mice, supporting the impression of a reduced inflammatory response in the absence of factor XI. Surprisingly, there was little evidence of DIC in mice of either genotype. Plasma levels of the contact factors factor XII and prekallikrein were reduced in WT mice after CLP, consistent with induction of contact activation. However, factor XII and PK levels were not reduced in FXI-/- animals, indicating factor XI deficiency blunted contact activation. Intravenous infusion of polyphosphate into WT mice also induced changes in factor XII, but had much less effect in FXI deficient mice. In vitro analysis revealed that factor XIa activates factor XII, and that this reaction is enhanced by polyanions such polyphosphate and nucleic acids. These data suggest that factor XI deficiency confers a survival advantage in the CLP sepsis model by altering the cytokine response to infection and blunting activation of the contact (kallikrein-kinin system. The findings support the hypothesis that factor XI functions as a bidirectional interface between contact activation and thrombin generation, allowing the two processes to influence each other.

  6. Removal of silver nanoparticles by coagulation processes

    International Nuclear Information System (INIS)

    Sun, Qian; Li, Yan; Tang, Ting; Yuan, Zhihua; Yu, Chang-Ping

    2013-01-01

    Highlights: • This study investigated the removal of AgNP suspensions by four regular coagulants. • The optimal removal efficiencies for the four coagulants were achieved at pH 7.5. • The removal efficiency of AgNPs was affected by the natural water characteristics. • TEM and XRD showed that AgNPs or silver-containing NPs were adsorbed onto the flocs. -- Abstract: Commercial use of silver nanoparticles (AgNPs) will lead to a potential route for human exposure via potable water. Coagulation followed by sedimentation, as a conventional technique in the drinking water treatment facilities, may become an important barrier to prevent human from AgNP exposures. This study investigated the removal of AgNP suspensions by four regular coagulants. In the aluminum sulfate and ferric chloride coagulation systems, the water parameters slightly affected the AgNP removal. However, in the poly aluminum chloride and polyferric sulfate coagulation systems, the optimal removal efficiencies were achieved at pH 7.5, while higher or lower of pH could reduce the AgNP removal. Besides, the increasing natural organic matter (NOM) would reduce the AgNP removal, while Ca 2+ and suspended solids concentrations would also affect the AgNP removal. In addition, results from the transmission electron microscopy and X-ray diffraction showed AgNPs or silver-containing nanoparticles were adsorbed onto the flocs. Finally, natural water samples were used to validate AgNP removal by coagulation. This study suggests that in the case of release of AgNPs into the source water, the traditional water treatment process, coagulation/sedimentation, can remove AgNPs and minimize the silver ion concentration under the well-optimized conditions

  7. Emergent self-similarity of cluster coagulation

    Science.gov (United States)

    Pushkin, Dmtiri O.

    A wide variety of nonequilibrium processes, such as coagulation of colloidal particles, aggregation of bacteria into colonies, coalescence of rain drops, bond formation between polymerization sites, and formation of planetesimals, fall under the rubric of cluster coagulation. We predict emergence of self-similar behavior in such systems when they are 'forced' by an external source of the smallest particles. The corresponding self-similar coagulation spectra prove to be power laws. Starting from the classical Smoluchowski coagulation equation, we identify the conditions required for emergence of self-similarity and show that the power-law exponent value for a particular coagulation mechanism depends on the homogeneity index of the corresponding coagulation kernel only. Next, we consider the current wave of mergers of large American banks as an 'unorthodox' application of coagulation theory. We predict that the bank size distribution has propensity to become a power law, and verify our prediction in a statistical study of the available economical data. We conclude this chapter by discussing economically significant phenomenon of capital condensation and predicting emergence of power-law distributions in other economical and social data. Finally, we turn to apparent semblance between cluster coagulation and turbulence and conclude that it is not accidental: both of these processes are instances of nonlinear cascades. This class of processes also includes river network formation models, certain force-chain models in granular mechanics, fragmentation due to collisional cascades, percolation, and growing random networks. We characterize a particular cascade by three indicies and show that the resulting power-law spectrum exponent depends on the indicies values only. The ensuing algebraic formula is remarkable for its simplicity.

  8. A fully discrete energy stable scheme for a phase filed moving contact line model with variable densities and viscosities

    KAUST Repository

    Zhu, Guangpu

    2018-01-26

    In this paper, a fully discrete scheme which considers temporal and spatial discretizations is presented for the coupled Cahn-Hilliard equation in conserved form with the dynamic contact line condition and the Navier-Stokes equation with the generalized Navier boundary condition. Variable densities and viscosities are incorporated in this model. A rigorous proof of energy stability is provided for the fully discrete scheme based on a semi-implicit temporal discretization and a finite difference method on the staggered grids for the spatial discretization. A splitting method based on the pressure stabilization is implemented to solve the Navier-Stokes equation, while the stabilization approach is also used for the Cahn-Hilliard equation. Numerical results in both 2-D and 3-D demonstrate the accuracy, efficiency and decaying property of discrete energy of the proposed scheme.

  9. Contribution to the development and the modelling of an ultrasonic conformable phased array transducer for the contact inspection of 3D complex geometry components

    International Nuclear Information System (INIS)

    Guedes, O.

    2005-04-01

    With the difficulties encountered for the exploration of complex shape surfaces, particularly in nuclear industry, the ultrasonic conformable phased array transducer allows a non destructive evaluation of parts with 3D complex parts. For this, one can use the Smart Contact Transducer principle to generate an ultrasonic field by adaptive dynamic focalisation, with a matrix array composed of independent elements moulded in a soft resin. This work deals with the electro-acoustic conception, with the realization of such a prototype and with the study of it's mechanical and acoustic behaviour. The array design is defined using a radiation model adapted to the simulation of contact sources on a free surface. Once one have defined the shape of the radiating elements, a vibratory analysis using finite elements method allows the determination of the emitting structure with 1-3 piezocomposite, witch leads to the realization of emitting-receiving elements. With the measurement of the field transmitted by such elements, we deduced new hypothesis to change the model of radiation. Thus one can take into account normal and tangential stresses calculated with finite element modelling at the interface between the element and the propagation medium, to use it with the semi-analytical model. Some vibratory phenomena dealing with fluid coupling of contact transducers have been studied, and the prediction of the transverse wave radiation profile have been improved. The last part of this work deals with the realization of the first prototype of the conformable phased array transducer. For this a deformation measuring system have been developed, to determine the position of each element on real time with the displacement of the transducer on complex shape surfaces. With those positions, one can perform the calculation of the a delay law intended for the adaptive dynamic focusing of the desired ultrasonic field. The conformable phased array transducer have been characterized in

  10. Contacting gases and liquids

    International Nuclear Information System (INIS)

    Robinson, L.F.; Cahalan, M.J.

    1980-01-01

    A process is described for contacting substantially immiscible phases to transfer material from one phase to another, which comprises passing the phases through a contactor, while causing portions of at least one phase to be repeatedly passed through at least one other phase. One phase in the contactor is gaseous, and another liquid. A further phase can be liquid or solid The process may be used for extracting impurities from china clay, or extracting uranium values from ore with oxygen gas acting to oxidise the uranium. (author)

  11. Non-Contact Sensor for Long-Term Continuous Vital Signs Monitoring: A Review on Intelligent Phased-Array Doppler Sensor Design

    Science.gov (United States)

    Hall, Travis; Nguyen, Tam Q.; Mayeda, Jill C.; Lie, Paul E.; Lopez, Jerry; Banister, Ron E.

    2017-01-01

    It has been the dream of many scientists and engineers to realize a non-contact remote sensing system that can perform continuous, accurate and long-term monitoring of human vital signs as we have seen in many Sci-Fi movies. Having an intelligible sensor system that can measure and record key vital signs (such as heart rates and respiration rates) remotely and continuously without touching the patients, for example, can be an invaluable tool for physicians who need to make rapid life-and-death decisions. Such a sensor system can also effectively help physicians and patients making better informed decisions when patients’ long-term vital signs data is available. Therefore, there has been a lot of research activities on developing a non-contact sensor system that can monitor a patient’s vital signs and quickly transmit the information to healthcare professionals. Doppler-based radio-frequency (RF) non-contact vital signs (NCVS) monitoring system are particularly attractive for long term vital signs monitoring because there are no wires, electrodes, wearable devices, nor any contact-based sensors involved so the subjects may not be even aware of the ubiquitous monitoring. In this paper, we will provide a brief review on some latest development on NCVS sensors and compare them against a few novel and intelligent phased-array Doppler-based RF NCVS biosensors we have built in our labs. Some of our NCVS sensor tests were performed within a clutter-free anechoic chamber to mitigate the environmental clutters, while most tests were conducted within the typical Herman-Miller type office cubicle setting to mimic a more practical monitoring environment. Additionally, we will show the measurement data to demonstrate the feasibility of long-term NCVS monitoring. The measured data strongly suggests that our latest phased array NCVS system should be able to perform long-term vital signs monitoring intelligently and robustly, especially for situations where the subject is

  12. Non-Contact Sensor for Long-Term Continuous Vital Signs Monitoring: A Review on Intelligent Phased-Array Doppler Sensor Design

    Directory of Open Access Journals (Sweden)

    Travis Hall

    2017-11-01

    Full Text Available It has been the dream of many scientists and engineers to realize a non-contact remote sensing system that can perform continuous, accurate and long-term monitoring of human vital signs as we have seen in many Sci-Fi movies. Having an intelligible sensor system that can measure and record key vital signs (such as heart rates and respiration rates remotely and continuously without touching the patients, for example, can be an invaluable tool for physicians who need to make rapid life-and-death decisions. Such a sensor system can also effectively help physicians and patients making better informed decisions when patients’ long-term vital signs data is available. Therefore, there has been a lot of research activities on developing a non-contact sensor system that can monitor a patient’s vital signs and quickly transmit the information to healthcare professionals. Doppler-based radio-frequency (RF non-contact vital signs (NCVS monitoring system are particularly attractive for long term vital signs monitoring because there are no wires, electrodes, wearable devices, nor any contact-based sensors involved so the subjects may not be even aware of the ubiquitous monitoring. In this paper, we will provide a brief review on some latest development on NCVS sensors and compare them against a few novel and intelligent phased-array Doppler-based RF NCVS biosensors we have built in our labs. Some of our NCVS sensor tests were performed within a clutter-free anechoic chamber to mitigate the environmental clutters, while most tests were conducted within the typical Herman-Miller type office cubicle setting to mimic a more practical monitoring environment. Additionally, we will show the measurement data to demonstrate the feasibility of long-term NCVS monitoring. The measured data strongly suggests that our latest phased array NCVS system should be able to perform long-term vital signs monitoring intelligently and robustly, especially for situations where the

  13. Hemorrhoidectomy: pedicle ligation vs pedicle coagulation

    International Nuclear Information System (INIS)

    Shaikh, B.S.; Balaoch, I.B.; Sohu, K.M.

    2015-01-01

    Objective: To compare the outcome of pedicle ligation vs pedicle coagulation haemorrhoidectomy. Methodology: This comparative prospective study was carried out at Department of Surgery, Ghulam Muhammad Maher Medcial College Hospital, Sukkur, Pakistan from January 2011 to January 2013 and included 300 patients of hemorrhoids. After routine workup, patients were randomly divided into two equal groups with one group receiving pedicle ligation and other pedicle coagulation for hemorrhoidectomy. Postoperatively they were followed for a period of 8 weeks for complications including pain, urinary retention, bleeding and anal stricture. Pain was recorded up to 10th postoperative day on the basis of visual analogue scale. Results: Mean age was 45 years and male to female ratio was 1.7:1. Mean operative time in pedicle ligation group was 15 min (range 14-20 min) and 17 min (15-25 min) in pedicle coagulation group. In Pedicle ligation group, pain was worst in 35 patients, moderate in 85 and mild in 30 patients; on the other hand in pedicle coagulation group, just 09 patients experienced worst pain. Urinary retention was observed in 44 patients in pedicle ligation group and 19 in pedicle coagulation group. Five patients in pedicle ligation group developed bleeding after their discharge from hospital; 7 patients in pedicle coagulation group reported secondary bleeding. Anal stricture was a rare complication and was found equally common in both the groups. Conclusion: Conventional hemorrhoidectomy with pedicle coagulation is an effective treatment modality for hemorrhoids and is associated with less chance of postoperative anal pain and urinary retention. (author)

  14. Magnetic particle imaging of blood coagulation

    Energy Technology Data Exchange (ETDEWEB)

    Murase, Kenya, E-mail: murase@sahs.med.osaka-u.ac.jp; Song, Ruixiao; Hiratsuka, Samu [Department of Medical Physics and Engineering, Division of Medical Technology and Science, Faculty of Health Science, Graduate School of Medicine, Osaka University, Osaka 565-0871 (Japan)

    2014-06-23

    We investigated the feasibility of visualizing blood coagulation using a system for magnetic particle imaging (MPI). A magnetic field-free line is generated using two opposing neodymium magnets and transverse images are reconstructed from the third-harmonic signals received by a gradiometer coil, using the maximum likelihood-expectation maximization algorithm. Our MPI system was used to image the blood coagulation induced by adding CaCl{sub 2} to whole sheep blood mixed with magnetic nanoparticles (MNPs). The “MPI value” was defined as the pixel value of the transverse image reconstructed from the third-harmonic signals. MPI values were significantly smaller for coagulated blood samples than those without coagulation. We confirmed the rationale of these results by calculating the third-harmonic signals for the measured viscosities of samples, with an assumption that the magnetization and particle size distribution of MNPs obey the Langevin equation and log-normal distribution, respectively. We concluded that MPI can be useful for visualizing blood coagulation.

  15. Coagulation management in patients undergoing neurosurgical procedures.

    Science.gov (United States)

    Robba, Chiara; Bertuetti, Rita; Rasulo, Frank; Bertuccio, Alessando; Matta, Basil

    2017-10-01

    Management of coagulation in neurosurgical procedures is challenging. In this contest, it is imperative to avoid further intracranial bleeding. Perioperative bleeding can be associated with a number of factors, including anticoagulant drugs and coagulation status but is also linked to the characteristic and the site of the intracranial disorder. The aim of this review will be to focus primarily on the new evidence regarding the management of coagulation in patients undergoing craniotomy for neurosurgical procedures. Antihemostatic and anticoagulant drugs have shown to be associated with perioperative bleeding. On the other hand, an increased risk of venous thromboembolism and hypercoagulative state after elective and emergency neurosurgery, in particular after brain tumor surgery, has been described in several patients. To balance the risk between thrombosis and bleeding, it is important to be familiar with the perioperative changes in coagulation and with the recent management guidelines for anticoagulated patients undergoing neurosurgical procedures, in particular for those taking new direct anticoagulants. We have considered the current clinical trials and literature regarding both safety and efficacy of deep venous thrombosis prophylaxis in the neurosurgical population. These were mainly trials concerning both elective surgical and intensive care patients with a poor grade intracranial bleed or multiple traumas with an associated severe traumatic brain injury (TBI). Coagulation management remains a major issue in patients undergoing neurosurgical procedures. However, in this field of research, literature quality is poor and further studies are necessary to identify the best strategies to minimize risks in this group of patients.

  16. Intraventricular hemorrhage in preterm infants: coagulation perspectives.

    Science.gov (United States)

    Kuperman, Amir A; Kenet, Gili; Papadakis, Emmanuel; Brenner, Benjamin

    2011-10-01

    It has long been considered that a severe coagulation deficiency in premature newborns could be a major contributing factor in the occurrence of intraventricular hemorrhage (IVH). High-grade IVH has also been shown to coincide with severe derangement of coagulation in extremely low birth weight infants. This review focuses on the relevance of the physiologically developing immature hemostatic system to IVH, and the potential benefit of agents affecting hemostasis for IVH therapy or prevention in preterm infants. The findings of small, open-label interventional studies on the effect of ethamsylate, vitamin K, fresh frozen plasma, recombinant activated factor VII, and prothrombin complex concentrate on the premature coagulation system will be reviewed. © Thieme Medical Publishers.

  17. Infrared coagulation: a new treatment for hemorrhoids

    International Nuclear Information System (INIS)

    Leicester, R.J.; Nicholls, R.J.; Mann, C.V.

    1981-01-01

    Many methods, which have effectively reduced the number of patients requiring hospital admission, have been described for the outpatient treatment of hemorrhoids. However, complications have been reported, and the methods are often associated with unpleasant side effects. In 1977 Neiger et al. described a new method that used infrared coagulation, which produced minimal side effects. The authors have conducted a prospective, randomized trial to evaluate infrared coagulation compared with more traditional methods of treatment. The authors' results show that it may be more effective than injection sclerotherapy in treating non-prolapsing hemorrhoids and that it compares favorably with rubber band ligation in most prolapsing hemorrhoids. No complications occurred, and significantly fewer patients experienced pain after infrared coagulation

  18. An updated concept of coagulation with clinical implications.

    Science.gov (United States)

    Romney, Gregory; Glick, Michael

    2009-05-01

    Over the past century, a series of models have been put forth to explain the coagulation mechanism. The coagulation cascade/waterfall model has gained the most widespread acceptance. This model, however, has problems when it is used in different clinical scenarios. A more recently proposed cell-based model better describes the coagulation process in vivo and provides oral health care professionals (OHCPs) with a better understanding of the clinical implications of providing dental care to patients with potentially increased bleeding tendencies. The authors conducted a literature search using the PubMed database. They searched for key words including "coagulation," "hemostasis," "bleeding," "coagulation factors," "models," "prothrombin time," "activated partial thromboplastin time," "international normalized ratio," "anticoagulation therapy" and "hemophilia" separately and in combination. The coagulation cascade/waterfall model is insufficient to explain coagulation in vivo, predict a patient's bleeding tendency, or correlate clinical outcomes with specific laboratory screening tests such as prothrombin time, activated partial thromboplastin time and international normalized ratio. However, the cell-based model of coagulation that reflects the in vivo process of coagulation provides insight into the clinical ramifications of treating dental patients with specific coagulation factor deficiencies. Understanding the in vivo coagulation process will help OHCPs better predict a patient's bleeding tendency. In addition, applying the theoretical concept of the cell-based model of coagulation to commonly used laboratory screening tests for coagulation and bleeding will result in safer and more appropriate dental care.

  19. The investigation of coagulation activity of natural coagulants extracted from different strains of common bean

    Directory of Open Access Journals (Sweden)

    Šćiban Marina B.

    2010-01-01

    Full Text Available Coagulation and flocculation by adding chemicals are the methods that are usually used for removal of water turbidity. This study is concerned with the coagulation activity of extracts of various strains of bean. The aim was to ascertain if bean varieties influence coagulation activity. Active components were extracted from 1 g of ground sample with 100 ml distilled water. Contents of dry matter and nitrogen were specified in the solid samples, and the content of soluble nitrogen was determined in the extracts. These data were used to calculate the efficiency of extraction of nitrogen-containing compounds. The coagulation activity was assessed by jar test using synthetic turbid water, of the initial pH 9 and turbidity 35 NTU. The jar test was carried out by adding different amounts of extracts to model water, and stirring the content. After sedimentation for 1 h, residual turbidity was determined by turbidimeter and coagulation activity was calculated. The increment of organic matter concentration after the coagulation was also determined. These experiments confirmed that extracts of all investigated strains of bean could be used successfully as natural coagulants.

  20. Comparison of the level of residual coagulant activity in different cheese varieties.

    Science.gov (United States)

    Bansal, Nidhi; Fox, Patrick F; McSweeney, Paul L H

    2009-08-01

    The coagulant retained in cheese curd is a major contributor to proteolysis during ripening. The objective of this study was to quantify residual coagulant in 9 cheese varieties by measuring its activity on a synthetic heptapeptide (Pro-Thr-Glu-Phe-[NO2-Phe]-Arg-Leu) assayed using reversed-phase HPLC. The level of residual coagulant activity was highest in Camembert cheese, probably due to its low pH at whey drainage and the high moisture content of the cheese, followed in order by Feta=Port du Salut=Cheddar>Gouda>Emmental=Parmigiano Reggiano=low-moisture part-skim Mozzarella=Mozzarella di Bufala Campana. The high cooking temperature (50-54 degrees C) used during the manufacture of Emmental and Parmigiano Reggiano cheeses and the cooking and stretching step in hot water during the manufacture of Mozzarella cheese may be the reasons for the lowest residual coagulant activity in these cheeses. The level of residual coagulant activity was higher in Feta cheese made from milk concentrated by ultrafiltration than in conventional Feta.

  1. Vitamin K: from coagulation to calcification.

    Science.gov (United States)

    Paakkari, Ilari

    Vitamin K is not only essential for the synthesis of coagulation factors in the liver, but it also strengthens the bones and prevents calcification of the arteries. These effects are mediated through the same mechanism, i.e. carboxylation of Gla target proteins. The discovery of novel Gla proteins that are not associated with blood coagulation or calcium metabolism indicates that vitamin K has additional effects in the pancreas and the central nervous system, for example. As dietary supplements, vitamin K1 of plant origin and vitamins K2 of bacterial origin may exert different effects.

  2. THE RATIONALIZATION OF THE PARAMETERS OF MILK PROTEINS’ THERMO ACID COAGULATION BY BERRY COAGULANTS

    Directory of Open Access Journals (Sweden)

    Olena GREK

    2017-03-01

    Full Text Available This paper presents the results related to the influence of berry coagulant amount, its proactive acidity and duration of thermo acid coagulation on the process of milk proteins’ sedimentation. In the present work, the regression equations and response surface analysis were used to design and optimize an industrial bioprocess. Increase in the berry coagulant amount to 11 % and reduction of active acidity to 2.4 units were determined. pH up to 3 minutes is characterized by the highest processes of destabilization. Moreover, it improves the organoleptic properties and has the biggest impact on the yield of protein-berry clot (to 25 % and active acidity.

  3. MRI-guided Therapeutic Ultrasound : In vitro Validation of a New MR Compatible, Phased Array, Contact Endorectal Ultrasound Transducer with Active Feedback Control of Temperature Evolution

    Science.gov (United States)

    Salomir, Rares; Rata, Mihaela; Lafon, Cyril; Melodelima, David; Chapelon, Jean-Yves; Mathias, Adrien; Cotton, François; Bonmartin, Alain; Cathignol, Dominique

    2006-05-01

    Contact application of high intensity ultrasound was demonstrated to be suitable for thermal ablation of sectorial tumours of the digestive duct. Experimental validation of a new MR compatible ultrasonic device is described here, dedicated to the minimal invasive therapy of localized colorectal cancer. This is a cylindrical 1D 64-element phased array transducer of 14 mm diameter and 25 mm height (Imasonic, France) allowing electronic rotation of the acoustic beam. Operating frequency ranges from 3.5 to 4.0 MHz and up to 5 effective electrical watts per element are available. A plane wave is reconstructed by simultaneous excitation of eigth adjacent elements with an appropriate phase law. Driving electronics operates outside the Faraday cage of the scanner and provides fast switching capabilities. Excellent passive and active compatibility with the MRI data acquisition has been demonstrated. In addition, feasibility of active temperature control has been demonstrated based on real-time data export out of the MR scanner and a PID feedback algorithm. Further studies will address the in-vivo validation and the integration of a miniature NMR coil for increased SNR in the near field.

  4. Novel approaches to the management of disseminated intravascular coagulation

    NARCIS (Netherlands)

    Levi, M. [=Marcel M.; de Jonge, E.; van der Poll, T.; ten Cate, H.

    2000-01-01

    Disseminated intravascular coagulation (DIC) is a syndrome characterized by systemic intravascular activation of coagulation, leading to widespread deposition of fibrin in the circulation. We addressed the issue of whether there is evidence that this fibrin deposition contributes to multiple organ

  5. [Perioperative changes of coagulation functions in the local advanced liver cancer patients receiving liver transplantation].

    Science.gov (United States)

    Wang, Hao-Yuan; Zhao, Qing-Yu; Yuan, Yun-Fei

    2008-07-01

    Liver transplantation is widely accepted as an effective therapy of hepatoma. Perioperative dynamic observation of coagulation function is important for graft-receivers. This study was to explore perioperative changes of coagulation functions in the local advanced liver cancer patients who received liver transplantation. Clinical data of 31 local advanced liver cancer patients, underwent liver transplantation from Sep. 2003 to Jan. 2007, were analyzed. Platelet (PLT) counting, prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen (Fib) and international normalized ratio (INR) before operation, at anhepatic phase and the first week after operation were analyzed to evaluate congulation function. The coagulation functions of most patients were normal before operation. The six parameters varied significantly at anhepatic phase and on most days of the first week after operation when compared with the preoperative levels (Pfunctions of local advanced liver cancer patients shift from hypocoagulatory to hypercoagulatory or normal in perioperative period, therefore, prevention of bleeding should be focused on at anhepatic phase and on 1-2 days after operation while prevention of thrombosis should be focused on after the first week after operation. The degree of liver cirrhosis and Child-Pugh level could help to evaluate postoperative coagulation disorder.

  6. Allergic Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Meltem Önder

    2009-03-01

    Full Text Available Allergic contact dermatitis is the delayed type hypersensitivity reaction to exogenous agents. Allergic contact dermatitis may clinically present acutely after allergen exposure and initial sensitization in a previously sensitized individual. Acute phase is characterized by erythematous, scaly plaques. In severe cases vesiculation and bullae in exposed areas are very characteristic. Repeated or continuous exposure of sensitized individual with allergen result in chronic dermatitis. Lichenification, erythematous plaques, hyperkeratosis and fissuring may develop in chronic patients. Allergic contact dermatitis is very common dermatologic problem in dermatology daily practice. A diagnosis of contact dermatitis requires the careful consideration of patient history, physical examination and patch testing. The knowledge of the clinical features of the skin reactions to various contactans is important to make a correct diagnosis of contact dermatitis. It can be seen in every age, in children textile product, accessories and touch products are common allergens, while in adults allergic contact dermatitis may be related with topical medicaments. The contact pattern of contact dermatitis depends on fashion and local traditions as well. The localization of allergic reaction should be evaluated and patients’ occupation and hobbies should be asked. The purpose of this review is to introduce to our collaques up dated allergic contact dermatitis literatures both in Turkey and in the World.

  7. Contact Line Dynamics

    Science.gov (United States)

    Kreiss, Gunilla; Holmgren, Hanna; Kronbichler, Martin; Ge, Anthony; Brant, Luca

    2017-11-01

    The conventional no-slip boundary condition leads to a non-integrable stress singularity at a moving contact line. This makes numerical simulations of two-phase flow challenging, especially when capillarity of the contact point is essential for the dynamics of the flow. We will describe a modeling methodology, which is suitable for numerical simulations, and present results from numerical computations. The methodology is based on combining a relation between the apparent contact angle and the contact line velocity, with the similarity solution for Stokes flow at a planar interface. The relation between angle and velocity can be determined by theoretical arguments, or from simulations using a more detailed model. In our approach we have used results from phase field simulations in a small domain, but using a molecular dynamics model should also be possible. In both cases more physics is included and the stress singularity is removed.

  8. Characterisation of coal washery effluent and optimisation of coagulation behaviour of Moringa oleifera seed as a coagulant.

    Science.gov (United States)

    Kapse, Gaurav; Patoliya, Pruthvi; Samadder, S R

    2017-03-01

    The huge quantity of effluent generated in coal washing processes contains large amount of suspended and dissolved solids, clay minerals, coal fines and other impurities associated with raw coal. The present system of recirculation of the effluent is found to be ineffective in removing colloidal fines, which is the major part of the impurities present in washery effluent. Hence, there is a need for the assessment of a better technique for an efficient removal of these impurities. This study deals with detailed characterisation of coal washery effluent and fine particles present in it. For efficient removal of impurities, the suitability of biocoag-flocculation process using Moringa oleifera seed biomass as a natural coagulant was examined. Various doses of M. oleifera ranging from 0.2 to 3 mL/L were used in order to determine the optimal conditions. The impact of the variations in pH of the effluent (2-10), contact time (5-30 min), settlement time (5-50 min), temperature (10-50 °C) and the effluent dilution (1:0-1:5) was also assessed to optimise the treatment process. Post treatment analysis was carried out for determination of the different parameters such as pH, conductivity, turbidity, solids and settling velocity. Excellent reduction in turbidity (97.42%) and suspended solids (97.78%) was observed at an optimum dose of M. oleifera seed coagulant of 0.8 mL/L with an optimum contact time of 15 and at 20 min of settling time. In comparison with very few past studies of M. oleifera in the treatment of coal washery effluent with high dose and inadequate removal, this study stands to be a major highlight with low dose and high removal of the impurities. M. oleifera coagulant is considered to be an environment-friendly material, therefore, its application is recommended for simple and efficient treatment of coal washery effluent.

  9. Coagulation activity in liver disease | Reza | Internet Journal of ...

    African Journals Online (AJOL)

    Patients with advanced hepatic failure may present with the entire spectrum of coagulation factor deficiencies. This study was designed to determine laboratory abnormalities in coagulation in chronic liver disease and the association of these abnormalities with the extent of chronic hepatitis and cirrhosis. Coagulation ...

  10. Quinine-induced disseminated intravascular coagulation.

    Science.gov (United States)

    Spearing, R L; Hickton, C M; Sizeland, P; Hannah, A; Bailey, R R

    Recurrent disseminated intravascular coagulation occurred in 3 women after ingestion of quinine tablets for cramp. All had circulating quinine-dependent antibodies to platelets and in 2 there was initial evidence of antibody consumption, with low titres that rose steeply over the next few days and remained high for many months.

  11. Brownian coagulation at high particle concentrations

    NARCIS (Netherlands)

    Trzeciak, T.M.

    2012-01-01

    The process of Brownian coagulation, whereby particles are brought together by thermal motion and grow by collisions, is one of the most fundamental processes influencing the final properties of particulate matter in a variety of technically important systems. It is of importance in colloids,

  12. Coagulation-flocculation studies of wastewaters

    NARCIS (Netherlands)

    Leentvaar, J.

    1982-01-01

    Although coagulation-flocculation processes have been practiced world-wide for almost a century in water treatment, several problems both in the theoretical and in the applied field have not been resolved yet. Especially interpretation of practical results with respect to governing

  13. 21 CFR 864.5400 - Coagulation instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...

  14. Quantifying interspecific coagulation efficiency of phytoplankton

    DEFF Research Database (Denmark)

    Hansen, J.L.S.; Kiørboe, Thomas

    1997-01-01

    . nordenskjoeldii. Mutual coagulation between Skeletonema costatum and the non-sticky cel:ls of Ditylum brightwellii also proceeded with hall the efficiency of S. costatum alone. The latex beads were suitable to be used as 'standard particles' to quantify the ability of phytoplankton to prime aggregation...

  15. Comparison of electrocoagulation and chemical coagulation ...

    African Journals Online (AJOL)

    In this work, electrocoagulation and chemical coagulation were applied to the exit effluent of a textile factory located at Douala (Cameroon).The investigations were focused on the operational (pH, conductivity) and pollution parameters (COD, total phosphorus, turbidity). The electrolytic treatment was carried out with 0.4 A ...

  16. TRAITEMENT DES EAUX USEES PAR COAGULATION-FLOCULATION EN UTILISANT LE SULFATE D’ALUMINIUM COMME COAGULANT

    OpenAIRE

    Nora SEGHAIRI; Leila MIMECHE; Adel BOUZID; Yassir AYACHI

    2017-01-01

    Domestic wastewater treatment by coagulation-flocculation is widely used internationally. This treatment reduces color and turbidity, indicating organic and inorganic contaminants, but at acceptable levels for treated waste water discharged into the receiving environment. The objective of this study is to optimize the treatment of wastewater by coagulation-flocculation using aluminum sulphate as a coagulant. Various reaction parameters are taken into account, such as the coagulant dose,...

  17. Enhanced coagulation for improving coagulation performance and reducing residual aluminum combining polyaluminum chloride with diatomite.

    Science.gov (United States)

    Hu, Wenchao; Wu, Chunde

    2016-01-01

    The feasibility of using enhanced coagulation, which combined polyaluminum chloride (PAC) with diatomite for improving coagulation performance and reducing the residual aluminum (Al), was discussed. The effects of PAC and diatomite dosage on the coagulation performance and residual Al were mainly investigated. Results demonstrated that the removal efficiencies of turbidity, dissolved organic carbon (DOC), and UV254 were significantly improved by the enhanced coagulation, compared with PAC coagulation alone. Meaningfully, the five forms of residual Al (total Al (TAl), total dissolved Al (TDAl), dissolved organic Al (DOAl), dissolved monomeric Al (DMAl), and dissolved organic monomeric Al (DOMAl)) all had different degrees of reduction in the presence of diatomite and achieved the lowest concentrations (0.185, 0.06, 0.053, 0.014, and 0 mg L(-1), respectively) at a PAC dose of 15 mg L(-1) and diatomite dose of 40 mg L(-1). In addition, when PAC was used as coagulant, the majority of residual Al existed in dissolved form (about 31.14-70.16%), and the content of DOMAl was small in the DMAl.

  18. Effect of intravenous administration of dextrose on coagulation in healthy dogs.

    Science.gov (United States)

    Gonzales, Jennifer L; Hanel, Rita M; Hansen, Bernie D; Marks, Steve L

    2011-04-01

    To investigate effects of IV administration of dextrose on coagulation in healthy dogs. 7 dogs. Thromboelastography and coagulation panel analysis were used to assess coagulation. Samples (S1 through S9) were collected during the study phases: phase 0 (S1 [baseline]); phase 1 (S2 and S3), infusion of crystalloid fluid without dextrose; phase 2 (S4 and S5), high-rate dextrose infusion; phase 3 (S6, S7, and S8), moderate-rate dextrose infusion; and phase 4 (S9), discontinuation of fluids for 24 hours. In phase 3, dogs were allocated to 2 groups; 1 was administered dextrose at a rate comparable to total parental nutrition (40% of resting energy requirement; group A), and 1 was administered dextrose at rates equaling 70% to 90% of resting energy requirement (group B). Blood glucose concentration was measured every 2 hours. No dogs had clinically relevant sustained hyperglycemia. Maximum amplitude and elastic shear modulus were significantly lower at S6 than at S1 through S4. Concentration of D-dimer was significantly higher at S6 than at S1, S3, and S4 and significantly higher at S5 than at S3. Prothrombin time was significantly prolonged at S3, S5, S7, S8, and S9, compared with the value at S1. Activated partial thromboplastin time was significantly prolonged at S5 and S6, compared with values at S1, S2, S3, S4, and S9. IV administration of dextrose to healthy dogs at rates comparable to or higher than those for conventional parenteral nutrition resulted in mild but clinically unimportant interference with coagulation.

  19. Contact efflorescence as a pathway for crystallization of atmospherically relevant particles.

    Science.gov (United States)

    Davis, Ryan D; Lance, Sara; Gordon, Joshua A; Ushijima, Shuichi B; Tolbert, Margaret A

    2015-12-29

    Inadequate knowledge of the phase state of atmospheric particles represents a source of uncertainty in global climate and air quality models. Hygroscopic aqueous inorganic particles are often assumed to remain liquid throughout their atmospheric lifetime or only (re)crystallize at low relative humidity (RH) due to the kinetic limitations of efflorescence (salt crystal nucleation and growth from an aqueous solution). Here we present experimental observations of a previously unexplored heterogeneous nucleation pathway that we have termed "contact efflorescence," which describes efflorescence initiated by an externally located solid particle coming into contact with the surface of a metastable aqueous microdroplet. This study demonstrates that upon a single collision, contact efflorescence is a pathway for crystallization of atmospherically relevant aqueous particles at high ambient RH (≤80%). Soluble inorganic crystalline particles were used as contact nuclei to induce efflorescence of aqueous ammonium sulfate [(NH4)2SO4], sodium chloride (NaCl), and ammonium nitrate (NH4NO3), with efflorescence being observed in several cases close to their deliquescence RH values (80%, 75%, and 62%, respectively). To our knowledge, these observations represent the highest reported efflorescence RH values for microdroplets of these salts. These results are particularly important for considering the phase state of NH4NO3, where the contact efflorescence RH (∼20-60%) is in stark contrast to the observation that NH4NO3 microdroplets do not homogeneously effloresce, even when exposed to extremely arid conditions (<1% RH). Considering the occurrence of particle collisions in the atmosphere (i.e., coagulation), these observations of contact efflorescence challenge many assumptions made about the phase state of inorganic aerosol.

  20. Magnetic Resonance Mediated Radio Frequency Coagulation for Vascular Repair

    Science.gov (United States)

    Zhao, Ming

    Purpose. Magnetic Resonance Mediated Radiofrequency Coagulation employs the RF heating effect of MRI scanning to coagulate biomaterials for repair of vascular defects. Coagulation of a protein biomaterial by MR-induced RF heating is a novel means to effect repair of defects such as aneurysms or arteriovenous malformations. Our novel method is to coagulate a thermosetting material (such as egg white, which can be used for investigating heat coagulation behavior and MR relaxation properties) delivered endovascularly by catheter and coagulated by RF-induced heating of an intracatheter resonant wire antenna in the scanner. Methods. Experiments were performed on a Siemens 1.5 T MRI scanner and a Bruker 14T NMR spectrometer. Egg white was brought to equilibrium at seven temperatures (20, 30, 40, 50, 60, 70 and 37 °C) in sequence. Measurement of the water spin-lattice relaxation time Ti, spin-spin relaxation time T2, spin-lattice relaxation time in the rotating frame T1p, or full width at half maximum of the MT spectrum were performed at each temperature. Relaxation parameters of raw egg white and egg white after coagulation at 70 °C were measured in the scanner at 20 °C to determine optimum inversion time, echo time and offset frequency for good image contrast between coagulated and uncoagulated protein. Finally, coagulation of egg white within a glass aneurysm phantom by RF heating in the scanner was performed to demonstrate the MR coagulation methodology and the ability to achieve image contrast between coagulated and uncoagulated biomaterial. Results. Water T2, T1p and MT gave the most definitive indication of the change from uncoagulated at low temperature to fully coagulated at 60 °C, while water T1 showed only the expected gradual increase with temperature, and no response to coagulation. MT weighted imaging is expected to be the optimum method to establish the coagulation condition of the biomaterial.

  1. Caveats in studies of the physiological role of polyphosphates in coagulation.

    Science.gov (United States)

    Lindahl, Tomas L; Ramström, Sofia; Boknäs, Niklas; Faxälv, Lars

    2016-02-01

    Platelet-derived polyphosphates (polyP), stored in dense granule and released upon platelet activation, have been claimed to enhance thrombin activation of coagulation factor XI (FXI) and to activate FXII directly. The latter claim is controversial and principal results leading to these conclusions are probably influenced by methodological problems. It is important to consider that low-grade contact activation is initiated by all surfaces and is greatly amplified by the presence of phospholipids simulating the procoagulant membranes of activated platelets. Thus, proper use of inhibitors of the contact pathway and a careful choice of materials for plates and tubes is important to avoid artefacts. The use of phosphatases used to degrade polyP has an important drawback as it also degrades the secondary activators ADP and ATP, which are released from activated platelets. In addition, the use of positively charged inhibitors, such as polymyxin B, to inhibit polyP in platelet-rich plasma and blood is problematic, as polymyxin B also slows coagulation in the absence of polyP. In conclusion we hope awareness of the above caveats may improve research on the physiological roles of polyP in coagulation. © 2016 Authors; published by Portland Press Limited.

  2. Evaluation of the process of coagulation/flocculation of produced water using Moringa oleifera Lam. as natural coagulant

    Energy Technology Data Exchange (ETDEWEB)

    Santana, C.R.; Pereira, D.F.; Sousa, S.C S N.; Silva, G.F. [Universidade Federal de Sergipe (UFSE), Sao Cristovao, SE (Brazil). Dept. de Engenharia Quimica], e-mail: claudia@ufs.br; Cavalcanti, E.B. [Universidade Tiradentes (UNIT), SE (Brazil). Inst. de Tecnologia e Pesquisa

    2010-07-15

    In the lifetime of an oil well, there comes a moment when a lot of water begins to be produced along with oil, either by the conditions of the reservoir, or as a result of water injection in the secondary recovery of the well. An important step in such process involves the treatment of the produced water by means of coagulation techniques. Therefore, the use of environmentally correct coagulants is presented as a viable alternative and has demonstrated advantages over the use of chemical coagulants. The plant of the genus Moringa, whose species is oleifera Lam, stands out as one of the most promising natural coagulants. The present study investigated the evaluation of the coagulation/flocculation of produced water, using seeds of Moringa oleifera Lam. as coagulant. The results were very significant, demonstrating that Moringa oleifera Lam. can be used as a natural coagulant in this type of treatment. (author)

  3. Facile Fabrication of Superhydrophobic Paper with Excellent Water Repellency and Moisture Resistance by Phase Separation

    Directory of Open Access Journals (Sweden)

    Pan Li

    2016-06-01

    Full Text Available A simple but effective method of fabricating superhydrophobic paper with excellent moisture resistance was developed by precipitating carnauba wax onto the surface of cellulose fibers using a phase separation method. Response surface methodology (RSM was used to optimize the effects of the preparation variables on the water contact angle (WCA of the paper surface. The four independent variables were carnauba wax concentration, immersion time, coagulation bath ratio (water/ethanol, and coagulation bath time. The optimal treatment conditions were as follows: wax concentration, 3.78% (wax/chloroform, w/v; immersion time, 1.46 h; coagulation bath ratio, 13/87 (water/ethanol, v/v; and coagulation bath time, 2.63 h. Under these conditions, the experimental WCA reached 152.7°, which agreed closely with the predicted value of 154.1°. The surface morphology of the superhydrophobic paper was characterized by scanning electron microscopy (SEM and atomic force microscopy (AFM, and the images showed that cluster-like carnauba wax aggregation completely covered the fiber surface, resulting in increased roughness. Moreover, the moisture resistance of the obtained superhydrophobic paper was evaluated. The results demonstrated that under high relative humidity conditions, the moisture resistance of the superhydrophobic paper significantly improved, and its tensile strength remained high.

  4. Neurosurgery contact handheld probe based on sapphire shaped crystal

    Science.gov (United States)

    Shikunova, I. A.; Stryukov, D. O.; Rossolenko, S. N.; Kiselev, A. M.; Kurlov, V. N.

    2017-01-01

    A handheld contact probe based on sapphire shaped crystal is developed for intraoperative spectrally-resolved optical diagnostics, laser coagulation and aspiration of malignant brain tissue. The technology was integrated into the neurosurgical workflow for intraoperative real-time identification and removing of invasive brain cancer.

  5. The contact activation proteins: a structure/function overview

    NARCIS (Netherlands)

    Meijers, J. C.; McMullen, B. A.; Bouma, B. N.

    1992-01-01

    In recent years, extensive knowledge has been obtained on the structure/function relationships of blood coagulation proteins. In this overview, we present recent developments on the structure/function relationships of the contact activation proteins: factor XII, high molecular weight kininogen,

  6. Ventricular metastasis resulting in disseminated intravascular coagulation

    Directory of Open Access Journals (Sweden)

    Davis Ian D

    2005-05-01

    Full Text Available Abstract Background Disseminated Intravascular Coagulation (DIC complicates up to 7% of malignancies, the commonest solid organ association being adenocarcinoma. Transitional Cell Carcinoma (TCC has rarely been associated with DIC. Case presentation A 74-year-old woman with TCC bladder and DIC was found to have a cardiac lesion suspicious for metastatic disease. The DIC improved with infusion of plasma and administration of Vitamin K, however the cardiac lesion was deemed inoperable and chemotherapy inappropriate; given the patients functional status. We postulate that direct activation of the coagulation cascade by the intraventricular metastasis probably triggered the coagulopathy in this patient. Conclusion Cardiac metastases should be considered in cancer patients with otherwise unexplained DIC. This may influence treatment choices.

  7. EFFECTS OF ORAL CONTRACEPTIVES ON COAGULATING FACTORS

    Directory of Open Access Journals (Sweden)

    H.R. Sadeghipour Roudsari.

    1997-06-01

    Full Text Available Thirty young, healthy, nonsmoking women (mean age approximately 28 years taking low-dose oral contraceptive pills were recruited for the study of the effects of these pills on coagulating factors. Twenty subjects were taking LD pill (Ethinyl estradiol 0.03 mg, levonorgestrel 0.15 mg and 10 others were taking Cilest (Ethinyl estradiol 0.035 mg, Norgestimate 0.25 mg for six months. The control subjects did not receive any oral contraceptives or other medications. Our results showed that:"n1. There is no significant difference between the effects of LD and Cilest (with a different progestin content on coagulating factors."n2. No significant changes were observed between both LD users and controls in PT, APTT, and fibrinogen levels."n3. No significant changes were observed between both Cilest users and controls in PT, APTT, and fibrinogen levels."n

  8. Coagulation of sheep intestinal and prefemoral lymph.

    Science.gov (United States)

    Hanley, C A; Johnston, M G; Nelson, W

    1988-06-01

    We have determined the most suitable method for the automated analysis of the clotting parameters in sheep intestinal and prefemoral lymph as defined by the Activated Partial Thromboplastin Times (APTT; measure of intrinsic coagulation pathway) and the Prothrombin Times (PT; measure of extrinsic coagulation pathway). As opposed to optical density systems, the use of a Fibro-System Fibrometer was found to provide the most consistent assessment of coagulation with the endpoint being the time to fibrin strand formation. We measured APTT in sheep intestinal and prefemoral lymph of 59.78 +/- 7.69 seconds and 51.03 +/- 10.49 seconds respectively. These values were more prolonged than those obtained from sheep blood plasma but only in the case of intestinal lymph were the differences significant (p less than 0.025). Human blood APTT values were significantly less than both sheep blood (p less than 0.05) and sheep intestinal (p less than 0.001) and prefemoral lymph (p less than 0.01). PT values were found to be 21.56 +/- 1.14 seconds in intestinal and 22.00 +/- 1.88 seconds in prefemoral lymph. These values were also significantly greater than those obtained from sheep blood (both p less than 0.001). Human blood PTs were significantly less than both sheep blood (p less than 0.001) and intestinal and prefemoral lymph (both p less than 0.001). Measurement of APTT and PT values in intestinal lymph and PT determinations in prefemoral lymph were not affected by storage in the refrigerator or freezer. There was some indication that APTT values in prefemoral samples were susceptible to storage artifacts; however, the differences in coagulation times were not significant.

  9. Disseminated intravascular coagulation in solid tumors

    International Nuclear Information System (INIS)

    Terzieff, V.; Alonso, I.; Vázquez, A.

    2004-01-01

    It is estimated that 20-25% of cases of disseminated intravascular coagulation (DIC) relate to an underlying neoplasia primarily hematologic. It is estimated that about 5% of patients with solid tumors have CID clinic, although the incidence of subclinical alterations is much higher. The CID is not limited to the activation of the coagulation cascade, which leads to bleeding micro thrombosis and consumption of coagulation factors. Solid tumors are frequently associated adenocarcinomas producers mucin (especially gastric), usually in the context of a disseminated disease. The mucin may act as a promoter of the cascade, but probably it is a multi-event. High levels of TNF to produced by the tumor mass and chemotherapy-induced cell lysis have Also linked. Although the bleeding is usually oriented diagnosis, the most frequent cause of death is thrombosis. There are no specific tests for diagnosis. Elevated levels of D-dimer and products oriented fibrinogen degradation diagnosis. No reduction fibrinogen and almost always, one thrombocytopenia consumption. Treatment is complex and there is no consensus on many points. To recover the lost factors for consumption, it is recommended to use fresh frozen plasma and / or washed red blood cells. the heparin anticoagulation low dose is indicated since the disease causal can not be controlled quickly, but should not be initiated if there thrombocytopenia 50.000.El under profuse bleeding can require the use of tranexamic acid or EACA. Acute DIC, the case of our patient, is rare and very serious

  10. Exact combinatorial approach to finite coagulating systems

    Science.gov (United States)

    Fronczak, Agata; Chmiel, Anna; Fronczak, Piotr

    2018-02-01

    This paper outlines an exact combinatorial approach to finite coagulating systems. In this approach, cluster sizes and time are discrete and the binary aggregation alone governs the time evolution of the systems. By considering the growth histories of all possible clusters, an exact expression is derived for the probability of a coagulating system with an arbitrary kernel being found in a given cluster configuration when monodisperse initial conditions are applied. Then this probability is used to calculate the time-dependent distribution for the number of clusters of a given size, the average number of such clusters, and that average's standard deviation. The correctness of our general expressions is proved based on the (analytical and numerical) results obtained for systems with the constant kernel. In addition, the results obtained are compared with the results arising from the solutions to the mean-field Smoluchowski coagulation equation, indicating its weak points. The paper closes with a brief discussion on the extensibility to other systems of the approach presented herein, emphasizing the issue of arbitrary initial conditions.

  11. Imaging of blood plasma coagulation at supported lipid membranes.

    Science.gov (United States)

    Faxälv, Lars; Hume, Jasmin; Kasemo, Bengt; Svedhem, Sofia

    2011-12-15

    The blood coagulation system relies on lipid membrane constituents to act as regulators of the coagulation process upon vascular trauma, and in particular the 2D configuration of the lipid membranes is known to efficiently catalyze enzymatic activity of blood coagulation factors. This work demonstrates a new application of a recently developed methodology to study blood coagulation at lipid membrane interfaces with the use of imaging technology. Lipid membranes with varied net charges were formed on silica supports by systematically using different combinations of lipids where neutral phosphocholine (PC) lipids were mixed with phospholipids having either positively charged ethylphosphocholine (EPC), or negatively charged phosphatidylserine (PS) headgroups. Coagulation imaging demonstrated that negatively charged SiO(2) and membrane surfaces exposing PS (obtained from liposomes containing 30% of PS) had coagulation times which were significantly shorter than those for plain PC membranes and EPC exposing membrane surfaces (obtained from liposomes containing 30% of EPC). Coagulation times decreased non-linearly with increasing negative surface charge for lipid membranes. A threshold value for shorter coagulation times was observed below a PS content of ∼6%. We conclude that the lipid membranes on solid support studied with the imaging setup as presented in this study offers a flexible and non-expensive solution for coagulation studies at biological membranes. It will be interesting to extend the present study towards examining coagulation on more complex lipid-based model systems. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Porous Aromatic Framework 48/Gel Hybrid Material Coated Solid-Phase Microextraction Fiber for the Determination of the Migration of Styrene from Polystyrene Food Contact Materials.

    Science.gov (United States)

    Jin, Yuanyuan; Li, Zhongyue; Yang, Lei; Xu, Jun; Zhao, Le; Li, Zhonghao; Niu, Jiajia

    2017-01-17

    A novel solid-phase microextraction (SPME) fiber was fabricated by a porous aromatic framework 48 (PAF-48)/gel hybrid material through a sol-gel process. PAF-48 is a porous organic framework (POF) material that was polymerized from 1,3,5-triphenylbenzene. The uniform pore structure, high surface area, continuous conjugate network, and hydrophobicity make PAF-48 expected to have special abilities to absorb and extract styrene as well as some other harmful volatile aromatic compounds (VACs). The PAF-48/gel-coated fiber was explored for the extraction of styrene and six VACs (benzene, toluene, ethylbenzene, and xylenes) from aqueous food simulants followed by gas chromatography (GC) separation. The fiber was found to be very sensitive for the determination of the target molecules with wide linear ranges (0.1-200 or 500 μg·kg -1 ), low limits of detection (LODs, 0.003-0.060 μg·kg -1 ), acceptable precisions (intraday relative standard deviation, RSD 200 times). Particularly for styrene, the PAF-48/gel-coated fiber exhibited a much lower LOD (0.006 μg·kg -1 ) compared with most of the reported fibers. Moreover, the PAF-48/gel-coated fiber had a high extraction selectivity for styrene and VACs over alcohols, phenols, aromatic amines, and alkanes and show a molecular sieving effect for the different molecule sizes. Finally, the PAF-48/gel-coated SPME fiber was successfully applied in GC for the determination of the specific migrations of styrene and VACs from polystyrene (PS) plastic food contact materials (FCMs).

  13. Risk of disseminated intravascular coagulation in patients undergoing US-guided transperineal prostatic biopsy

    International Nuclear Information System (INIS)

    Stella, M.S.; Comparato, D.; Camici, M.; Evangelisti, L.; Gaudio, V.; De Negri, F.; Talarico, L.; Giusti, C.; Morelli, G.

    1991-01-01

    Disseminated intravascular coagulation (DIC) is a severe life-threatening acute bleeding disorder. Traumatized tissues, tumors, necrotic tissues, or bacterial endotoxines release similar material in the blood to the tissutal factors activating the coagulation cascade. This preliminary study was aimed at verifying the risk of DIV in patients undergoing US-guided transperineal prostatic biopsy with Chiba and Tru-Cut needles. To evaluate the activation degree of coagulation factors in the circulation, the authors measured the concentrations of urinary fibrin degradation products in 10 patients undergoing US-guided transperineal prostatic biopsy, both before and after biopsy, every second hour, for 24 hours. Every tube of urine sample contained soya bean trypsin inhibitor and bovine thrombin to prevent any further fibrin degradation during incubation period for the possible presence of blood in urine samples. The results showed that 7/10 patients had marked increase in urinary fibrin degradation product levels (up to 800 XXXX%), with a 3-phase trend: early peak after 2-6 hours, middle peak after 6-14 hours, and late peak after 18-24 hours, which proved the activation of the coagulation cascade

  14. Coagulation performance of a novel poly-ferric-acetate (PFC) coagulant in phosphate-kaolin synthetic water treatment

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Yanxin; Lu, Jinpeng; Dong, Xiongzi; Yao, Chengli [Hefei Normal University, Hefei (China); Hao, Jianwen [Anhui Vocational and Technical College, Hefei (China)

    2017-10-15

    The process of coagulation-flocculation is increasingly applied in wastewater treatment. And the polymerized inorganic coagulants are widely used among these coagulation-flocculation processes. However, conventional coagulants using sulfates or chlorides as counter anion may give rise to corrosion. The purpose of this study was to synthesize PFC coagulants in which acetate is used as counter anion. The influences on the preparation of PFC were optimized. The synthesis was done at the optimum conditions, such as temperature of 60 .deg. C, the Fe/CH{sub 3}COOH molar ratio of 1 : 4.0 and reaction time of 6 h, respectively. The prepared PFC coagulants were characterized by Fourier transform infrared (FTIR) spectrophotometry and scanning electron microscopy (SEM). PFC was found to mainly form complexation polymeric species and present more cluster and lamellar structure. A series of jar tests were carried out to study the coagulation performance of PFC and PFS in phosphate-kaolin synthetic water treatment. Results showed that the coagulation performance of PFC was more efficient than PFS's in terms of the phosphorus removal efficiency and the residual turbidity. Due to using acetate as counter anion to iron, PFC is less harmful to the processes of water treatment and equipment than that of the conventional coagulants applied chlorides or sulfates. Therefore, PFC is a promising coagulant in the process of corrosion sensitive applications and the process of wastewater containing phosphorus treatment.

  15. LANL Contacts

    Science.gov (United States)

    : (505) 665-3664 ethics@lanl.gov Journalist queries Communications Office (505) 667-7000 Media contacts programs and employee resources. General Employee directory Emergency communication Communications Office (505) 667-7000 Ethics & Audits Internal Audit: (505) 665-3104 Ethics Office: (505) 667-7506 Fax

  16. Coagulation defects in experimental hepatic injury in the dog.

    Science.gov (United States)

    Osbaldiston, G W; Hoffman, M W

    1971-04-01

    Alteration in activity of blood coagulation factors in dogs with acute hepatic injury caused by oral carbon tetrachloride dosing was studied. Coagulation Factors II, VII and IX were dramatically reduced within 48 hours but recovered to normal in the next five days. Because surgery is rarely performed on dogs with hepatic necrosis, the use of fresh whole blood tranfusion to improve the coagulation defect in hepatic injury was also studied. Transfusion was found to have only a temporary beneficial effect.

  17. Coagulation and Adsorption Treatment of Printing Ink Wastewater

    OpenAIRE

    Klančnik, Maja

    2014-01-01

    The intention of the study was to improve the efficiency of total organic carbon (TOC) and colour removal from the wastewater samples polluted with flexographic printing ink following coagulation treatments with further adsorption onto activated carbons and ground orange peel. The treatment efficiencies were compared to those of further flocculation treatments and of coagulation and adsorption processes individually. Coagulation was a relatively effective single-treatment method, removing 99...

  18. Coagulation and flocculation of dissolved organic substances with organic polymers

    OpenAIRE

    Kvinnesland, Thomas

    2002-01-01

    Coagulation of natural organic matter (NOM) in water is a well-established process, enabling or enhancing the removal of these substances by different particle separation processes. The dominating coagulating agents used are, however, inorganic salts of iron (Fe3+) and aluminium (Al3+). The primary use of organic polymers is as flocculating agents for already coagulated aggregates. However, in recent years the use of cationic organic polymers have received increasing attent...

  19. Coagulation factor VII variants resistant to inhibitory antibodies.

    Science.gov (United States)

    Branchini, Alessio; Baroni, Marcello; Pfeiffer, Caroline; Batorova, Angelika; Giansily-Blaizot, Muriel; Schved, Jean F; Mariani, Guglielmo; Bernardi, Francesco; Pinotti, Mirko

    2014-11-01

    Replacement therapy is currently used to prevent and treat bleeding episodes in coagulation factor deficiencies. However, structural differences between the endogenous and therapeutic proteins might increase the risk for immune complications. This study was aimed at identifying factor (F)VII variants resistant to inhibitory antibodies developed after treatment with recombinant activated factor VII (rFVIIa) in a FVII-deficient patient homozygous for the p.A354V-p.P464Hfs mutation, which predicts trace levels of an elongated FVII variant in plasma. We performed fluorescent bead-based binding, ELISA-based competition as well as fluorogenic functional (activated FX and thrombin generation) assays in plasma and with recombinant proteins. We found that antibodies displayed higher affinity for the active than for the zymogen FVII (half-maximal binding at 0.54 ± 0.04 and 0.78 ± 0.07 BU/ml, respectively), and inhibited the coagulation initiation phase with a second-order kinetics. Isotypic analysis showed a polyclonal response with a large predominance of IgG1. We hypothesised that structural differences in the carboxyl-terminus between the inherited FVII and the therapeutic molecules contributed to the immune response. Intriguingly, a naturally-occurring, poorly secreted and 5-residue truncated FVII (FVII-462X) escaped inhibition. Among a series of truncated rFVII molecules, we identified a well-secreted and catalytically competent variant (rFVII-464X) with reduced binding to antibodies (half-maximal binding at 0.198 ± 0.003 BU/ml) as compared to the rFVII-wt (0.032 ± 0.002 BU/ml), which led to a 40-time reduced inhibition in activated FX generation assays. Taken together our results provide a paradigmatic example of mutation-related inhibitory antibodies, strongly support the FVII carboxyl-terminus as their main target and identify inhibitor-resistant FVII variants.

  20. Peculiarities of coagulation hemostasis disorders in patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Yakovlieva V.H.

    2015-09-01

    Full Text Available The violation of blood coagulation properties is observed in many diseases of the respiratory system, including chronic obstructive pulmonary disease (COPD. It is known that in a stable COPD phase release of proinflammatory cytokines in blood is observed, it leads to disturbance of hemostasis parameters toward hypercoagulation. The aim of our study was to determine possibility of coagulation disorders formation in patients with COPD in a stable phase of pathological process at different stages of disease course and identify relationship between coagulation parameters levels and degree of violation of ventilation lung function. Materials and methods. We examined 30 patients with COPD in a stable disease phase, included in the main group (FEV1 =49,5±15,5% of the due, there were 27 men (90.0%, 3 (30.0% women, mean age was 61,8±7,9 years, level of pack /years index - 34,2±15,3. The control group consisted of 10 healthy subjects matched with the patients of the main group by age and sex. All patients were divided into 2 subgroups. Subgroup 1 included 16 patients with moderate COPD, that is the level of FEV1>50% (61,8±7,4% of predicted, and subgroup 2 - 14 COPD patients with severe COPD, that is the level of FEV1 <50% (35,3±8,2% of predicted. Patients received standard treatment according to the disease stage. Main indicators of coagulation levels: prothrombin index (PI, prothrombin ratio (PR, international normalized ratio (INR, activated partial thromboplastin time (APTT, thrombin time (TT and antithrombin III (AT III were identified in all patients. Results. The levels of PI, PR and INR in the subgroup 1 differed significantly from those of in the subgroup 2, control group (p<0,05 and pointed at hypercoagulation, whereas in the subgroup 2 all indicators were absolutely identical with control group. Correlation link between the level of INR levels and FEV1 (r=-0,73; p<0.01 in patients of the main group was determined. Levels of APTT, TT and AT

  1. Tissue regenerating functions of coagulation factor XIII

    DEFF Research Database (Denmark)

    Soendergaard, C; Kvist, P H; Seidelin, J B

    2013-01-01

    The protransglutaminase factor XIII (FXIII) has recently gained interest within the field of tissue regeneration, as it has been found that FXIII significantly influences wound healing by exerting a multitude of functions. It supports haemostasis by enhancing platelet adhesion to damaged......-receptor 2 and the αVβ3 integrin is important for angiogenesis supporting formation of granulation tissue. Chronic inflammatory conditions involving bleeding and activation of the coagulation cascade have been shown to lead to reduced FXIII levels in plasma. Of particular importance for this review...

  2. Microwave tissue coagulation: effects of power and treatment time on coagulation size

    International Nuclear Information System (INIS)

    Kang, Seung Pyung; Kim, Young Hwan; Park, Dong Man; Kim, Jeong Seok; Park, Seo Young; Cha, Soon Joo; Hur, Gham

    1999-01-01

    To determine the effects of power and coagulation time on lesion size of ex-vivo bovine liver using microwaves. Six bovine livers were divided into two groups (first group : 30W output, second group : 60W output) and microwave coagulation was performed for 30, 60, and 120 sec. Thermal injury site was then observed by means of sonography, and the maximal transverse diameter of the echo-change portion after microwave coagulation was measured. On the section of specimen, maximal transverse diameters of the thermal injury site were measured by gross inspection and compared with the result of sonographic measurement. Maximal transverse diameters of hyperechoic lesions of the first group, as seen on sonography, were 8.3mm, 12.2mm, and 15.6mm, and the maximal transverse diameters of thermal injury sites on gross specimens were 9.1mm, 12.0mm, and 15.1mm, respectively. Maximal transverse diameters of hyperechoic lesions of the second group, as seen on sonography, were 12.1mm, 17.4mm, and 21.2mm and maximal transverse diameters of thermal injury sites on gross specimens were 13.2mm, 16.0mm, and 20.0mm, respectively. Statistically maximal transverse diameters of hyperechoic lesions, as seen on sonography, correlated closely with the gross findings of maximal transverse diameters of thermal injury sites (P < .05). Maximal transverse diameters of thermal injury sites were significantly increased as the output of the microwave coagulator and the duration of coagulation time increased (P < .05)

  3. Optoacoustic temperature determination and automatic coagulation control in rabbits

    Science.gov (United States)

    Schlott, Kerstin; Koinzer, Stefan; Ptaszynski, Lars; Luft, Susanne; Baade, Alex; Bever, Marco; Roider, Johann; Birngruber, Reginald; Brinkmann, Ralf

    2011-03-01

    Retinal laser photocoagulation is an established treatment method for many retinal diseases like macula edema or diabetic retinopathy. The selection of the laser parameters is so far based on post treatment evaluation of the lesion size and strength. Due to local pigment variations in the fundus and individual transmission the same laser parameters often lead to an overtreatment. Optoacoustic allows a non invasive monitoring of the retinal temperature increase during retinal laser irradiation by measuring the temperature dependent pressure amplitudes, which are induced by short probe laser pulses. A 75 ns/ 523 nm Nd:YLF was used as a probe laser at a repetition rate of 1 kHz, and a cw / 532 nm treatment laser for heating. A contact lens was modified with a ring-shaped ultrasonic transducer to detect the pressure waves at the cornea. Temperatures were collected for irradiations leading to soft or invisible lesions. Based on this data the threshold for denaturation was found. By analyzing the initial temperature increase, the further temperature development during irradiation could be predicted. An algorithm was found to calculate the irradiation time, which is needed for a soft lesion formation, from the temperature curve. By this it was possible to provide a real-time dosimetry by automatically switching off the treatment laser after the calculated irradiation time. Automatically controlled coagulations appear softer and more uniformly.

  4. A comparative study of coagulation, granular- and powdered-activated carbon for the removal of perfluorooctane sulfonate and perfluorooctanoate in drinking water treatment.

    Science.gov (United States)

    Pramanik, Biplob Kumar; Pramanik, Sagor Kumar; Suja, Fatihah

    2015-01-01

    Perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA) are persistent organic pollutants in the environment and their occurrence causes toxicological effects on humans. We examined different conventional coagulant treatments such as alum, ferric chloride and polyaluminium chloride in removing these compounds. These were then compared with a natural coagulant (Moringa oleifera). We also investigated the powdered-activated carbon (PAC) and granular-activated carbon (GAC) for removing these compounds. At an initial dose of 5 mg/L, polyaluminium chloride led to a higher reduction of PFOS/PFOA compared with alum which in turn was higher than ferric. The removal efficiency increased with the increase in coagulant dose and decrease in pH. M. oleifera was very effective in reducing PFOS and PFOA than conventional coagulants, with a reduction efficiencies of 65% and 72%, respectively, at a dose of 30 mg/L. Both PAC and GAC were very effective in reducing these compounds than coagulations. PAC led to a higher reduction in PFOS and PFOA than GAC due to its greater surface area and shorter internal diffusion distances. The addition of PAC (10 min contact time) with coagulation (at 5 mg/L dosage) significantly increased the removal efficiency, and the maximum removal efficiency was for M. oleifera with 98% and 94% for PFOS and PFOA, respectively. The reduction efficiency of PFOS/PFOA was reduced with the increase in dissolved organic concentration due to the adsorption competition between organic molecules and PFOS/PFOA.

  5. New treatment strategies for disseminated intravascular coagulation based on current understanding of the pathophysiology

    NARCIS (Netherlands)

    Levi, Marcel; de Jonge, Evert; van der Poll, Tom

    2004-01-01

    A variety of clinical conditions may cause systemic activation of coagulation, ranging from insignificant laboratory changes to severe disseminated intravascular coagulation (DIC). DIC consists of a widespread, systemic activation of coagulation, resulting in diffuse fibrin deposition in small and

  6. Natural organic matters removal efficiency by coagulation

    Science.gov (United States)

    Sapingi, Mohd Sharizal Mohd; Pishal, Munirah; Murshed, Mohamad Fared

    2017-10-01

    The presence of Natural Organic Matter (NOM) in surface water results in unwanted characteristics in terms of color, odor, and taste. NOM content reaction with free chlorine in treated water lowers the water quality further. Chlorine is added for disinfection and produces undesirable disinfection by-products (DPBs). DBPs in drinking water are carcinogenic to consumers and may promote cancerous cell development in the human body. This study was performed to compare the coagulant efficiency of aluminum sulfate (Alum) and ferric chloride (FeCl3) on NOM removal (as in UV254 absorbance) and turbidity removal under three pH conditions (pH 6, pH 7, and sample actual pH). The three sampling points for these studies were Jalan Baru River, Kerian River, and Redac Pond. Additional sampling points, such as Lubuk Buntar and a tubewell located in the Civil Engineering School, were included to observe differences in characteristics. DOC, UV absorbance, and full wavelength were tested, after which samples treated with alum were also tested to further analyze the NOM content. Based on UV254 absorbance and DOC data, specific UV value was calculated to obtain vital synopsis of the characteristics of NOM content, as well as coagulation efficiency.

  7. Temperature effects on flocculation, using different coagulants.

    Science.gov (United States)

    Fitzpatrick, C S B; Fradin, E; Gregory, J

    2004-01-01

    Temperature is known to affect flocculation and filter performance. Jar tests have been conducted in the laboratory, using a photometric dispersion analyser (PDA) to assess the effects of temperature on floc formation, breakage and reformation. Alum, ferric sulphate and three polyaluminium chloride (PACI) coagulants have been investigated for temperatures ranging between 6 and 29 degrees C for a suspension of kaolin clay in London tap water. Results confirm that floc formation is slower at lower temperatures for all coagulants. A commercial PACl product, PAX XL 19, produces the largest flocs for all temperatures; and alum the smallest. Increasing the shear rate results in floc breakage in all cases and the flocs never reform to their original size. This effect is most notable for temperatures around 15 degrees C. Breakage, in terms of floc size reduction, is greater for higher temperatures, suggesting a weaker floc. Recovery after increased shear is greater at lower temperatures implying that floc break-up is more reversible for lower temperatures.

  8. Effects of Puff-Adder Venom on Coagulation, Fibrinolysis and ...

    African Journals Online (AJOL)

    The in vitro and in vivo haematological effects of puffadder (Bitis arietans) venom in the baboon (Papio ursinus) with regard to its effect on coagulation, fibrinolysis and platelet aggregation were studied. There is a delay in the intrinsic coagulation mechanism with fibrinolysis and in vitro fibrinogenolysis. Normal human ...

  9. Evaluation of Moringa oleifera seed as coagulation aid for treatment ...

    African Journals Online (AJOL)

    Laboratory tests were carried out to evaluate the potentials of Moringa oleifera seed powder as a coagulation aid for removal of suspended particles in fish culture effluent. The standard jar test was used to investigate the dosage and mixing intensity required to optimize the use of the coagulant in removing of suspended ...

  10. Critical assessment of chitosan as coagulant to remove cyanobacteria

    NARCIS (Netherlands)

    Lürling, Miquel; Noyma, Natalia Pessoa; Magalhães, Leonardo de; Miranda, Marcela; Mucci, Maíra; Oosterhout, Frank van; Huszar, Vera L.M.; Marinho, Marcelo Manzi

    2017-01-01

    Removal of cyanobacteria from the water column using a coagulant and a ballast compound is a promising technique to mitigate nuisance. As coagulant the organic, biodegradable polymer chitosan has been promoted. Results in this study show that elevated pH, as may be common during cyanobacterial

  11. Disseminated intravascular coagulation in meningococcal sepsis. Case 7

    NARCIS (Netherlands)

    Zeerleder, S.; Zürcher Zenklusen, R.; Hack, C. E.; Wuillemin, W. A.

    2003-01-01

    We report on a man (age: 49 years), who died from severe meningococcal sepsis with disseminated intravascular coagulation (DIC), multiple organ dysfunction syndrome and extended skin necrosis. We discuss in detail the pathophysiology of the activation of coagulation and fibrinolysis during sepsis.

  12. Polyferric sulphate: preparation, characterisation and application in coagulation experiments.

    Science.gov (United States)

    Zouboulis, A I; Moussas, P A; Vasilakou, F

    2008-07-15

    The process of coagulation is a core environmental protection technology, which is mainly used in the water or wastewater treatment facilities. Research is now focused on the development of inorganic pre-polymerised coagulants. A characteristic example is PFS (polyferric sulphate), a relatively new pre-polymerised inorganic coagulant with high cationic charge. In this paper, the role of major parameters, including temperature, types of chemical reagents, ratio r=[OH]/[Fe], rate of base addition in the preparation stages of PFS were investigated. Furthermore, the prepared PFS was characterised based on typical properties, such as the percentage of the polymerised iron present in the compound, z-potential, pH, etc. Moreover, dynamics of coagulation process were examined by means of the Photometric Dispersion Analyzer (PDA). Finally, the coagulation efficiency of PFS in treating kaolin suspension and biologically pre-treated wastewater was evaluated in comparison with the respective conventional coagulant agent. The results indicate that certain parameters, such as the r value, the rate of base addition and the duration and temperature of the polymerisation stage, significantly affected the properties of the PFS. Additionally, the prepared PFS polymerised coagulants exhibit a significantly better coagulation performance than the respective non-polymerised one, i.e. ferric sulphate.

  13. Critical assessment of chitosan as coagulant to remove cyanobacteria

    NARCIS (Netherlands)

    Lurling, Miguel; Noyma, Natalia Pessoa; Magalhães, de Leonardo; Miranda, Marcela; Mucci, Maíra; Oosterhout, van F.; Huszar, Vera L.M.; Marinho, Marcelo Manzi

    2017-01-01

    Removal of cyanobacteria from the water column using a coagulant and a ballast compound is a promising technique to mitigate nuisance. As coagulant the organic, biodegradable polymer chitosan has been promoted. Results in this study show that elevated pH, as may be common during cyanobacterial

  14. Crosstalk between coagulation and inflammation in mastitis and metritis in dairy cows.

    Science.gov (United States)

    Bobowiec, Ryszard; Wessely-Szponder, Joanna; Hola, Piotr

    2009-06-01

    Coagulation and inflammation are closely related as part of the mechanisms of host defence during a severe infection. The aim of this study was to investigate the relation between thrombin as a factor in both the coagulative and inflammatory processes and neutrophil secretory function on the basis of lactoferrin (LF), elastase and myeloperoxidase release in the course of mastitis and metritis in cows. Thrombin generation was measured on the basis of hydrolysis of SAR-PRO-ARG-pNA and lactoferrin concentration was estimated by an ELISA method. The greatest thrombin generation was observed in the metritis group (1.18 +/- 0.62 IU). The level of LF was the highest in the group of cows with mastitis (0.74 +/- 0.55 mg/ml) in the first phase of the disease. In the second phase of the diseases the level of serum LF in cows with mastitis diminished to the value of 0.41 +/- 0.16 mg/ml, whereas in cows with metritis the level of LF increased to 0.51 +/- 0.17 mg/ml. This study reveals that the excessive production of thrombin not only causes hypercoagulatory disorders but also exaggerates neutrophil function by the release of some enzymes which may play a destructive role during disseminated intravascular coagulation (DIC). These enzymes also inhibit anticoagulative systems, thus potentially worsening the course of the disease.

  15. Coagulation profile in open and video-assisted thoracoscopic lobectomies

    DEFF Research Database (Denmark)

    Christensen, Thomas Decker; Vad, Henrik; Pedersen, Søren

    2018-01-01

    OBJECTIVES: Lung cancer patients are perceived to have a relatively high risk of venous thromboembolic events due to an activation of the coagulation system. In terms of activation of the coagulation system, the difference between video-assisted thoracoscopic surgery (VATS) and open lobectomies...... for primary lung cancer has not been investigated. The aim of this study was to compare the impact on the coagulation system in patients undergoing curative surgery for primary lung cancer by either VATS or open lobectomies. METHODS: In total, 62 patients diagnosed with primary lung cancer were allocated...... to either VATS (n = 32) or open lobectomies (n = 30). All patients received subcutaneous injections with dalteparin (Fragmin®) 5000 IE once daily. The coagulation was assessed pre- and intraoperatively, and the first 2 days postoperatively by standard coagulation blood tests, thromboelastometry (ROTEM...

  16. Interplay between coagulation and vascular inflammation in sickle cell disease

    Science.gov (United States)

    Sparkenbaugh, Erica; Pawlinski, Rafal

    2013-01-01

    Sickle cell disease is the most common inherited hematologic disorder that leads to the irreversible damage of multiple organs. Although sickling of red blood cells and vaso-occlusion are central to the pathophysiology of sickle cell disease the importance of hemolytic anemia and vasculopathy has been recently recognized. Hypercoagulation state is another prominent feature of sickle cell disease and is mediated by activation of both intrinsic and extrinsic coagulation pathways. Growing evidence demonstrates that coagulation may not only contribute to the thrombotic complications, but also to vascular inflammation associated with this disease. This article summarizes the role of vascular inflammation and coagulation activation, discusses potential mechanisms responsible for activation of coagulation and reviews recent data demonstrating the crosstalk between coagulation and vascular inflammation in sickle cell disease. PMID:23593937

  17. Effects of conjugated estrogens/bazedoxifene on lipid and coagulation variables

    DEFF Research Database (Denmark)

    Skouby, Sven O; Pan, Kaijie; Thompson, John R

    2015-01-01

    OBJECTIVE: This study aims to evaluate the effects of conjugated estrogens (CE)/bazedoxifene (BZA) on lipid and coagulation variables in a randomized, double-blind, placebo- and active-controlled phase 3 study of nonhysterectomized postmenopausal women. METHODS: The Selective estrogens, Menopause......, And Response to Therapy (SMART)-5 trial evaluated the efficacy and safety of CE/BZA in postmenopausal women (N = 1,843) with menopausal symptoms. Lipid (N = 1,843) and coagulation (N = 590) variables were assessed in women receiving daily CE 0.45 mg/BZA 20 mg, CE 0.625 mg/BZA 20 mg, BZA 20 mg, CE 0.45 mg...... reassurance that CE/BZA does not adversely affect lipid metabolism or hemostatic balance. In accordance, the incidences of venous thromboembolic events and cardiovascular events in postmenopausal women are similar to those observed with placebo....

  18. Contact angle and local wetting at contact line.

    Science.gov (United States)

    Li, Ri; Shan, Yanguang

    2012-11-06

    This theoretical study was motivated by recent experiments and theoretical work that had suggested the dependence of the static contact angle on the local wetting at the triple-phase contact line. We revisit this topic because the static contact angle as a local wetting parameter is still not widely understood and clearly known. To further clarify the relationship of the static contact angle with wetting, two approaches are applied to derive a general equation for the static contact angle of a droplet on a composite surface composed of heterogeneous components. A global approach based on the free surface energy of a thermodynamic system containing the droplet and solid surface shows the static contact angle as a function of local surface chemistry and local wetting state at the contact line. A local approach, in which only local forces acting on the contact line are considered, results in the same equation. The fact that the local approach agrees with the global approach further demonstrates the static contact angle as a local wetting parameter. Additionally, the study also suggests that the wetting described by the Wenzel and Cassie equations is also the local wetting of the contact line rather than the global wetting of the droplet.

  19. Coagulant recovery and reuse for drinking water treatment.

    Science.gov (United States)

    Keeley, James; Jarvis, Peter; Smith, Andrea D; Judd, Simon J

    2016-01-01

    Coagulant recovery and reuse from waterworks sludge has the potential to significantly reduce waste disposal and chemicals usage for water treatment. Drinking water regulations demand purification of recovered coagulant before they can be safely reused, due to the risk of disinfection by-product precursors being recovered from waterworks sludge alongside coagulant metals. While several full-scale separation technologies have proven effective for coagulant purification, none have matched virgin coagulant treatment performance. This study examines the individual and successive separation performance of several novel and existing ferric coagulant recovery purification technologies to attain virgin coagulant purity levels. The new suggested approach of alkali extraction of dissolved organic compounds (DOC) from waterworks sludge prior to acidic solubilisation of ferric coagulants provided the same 14:1 selectivity ratio (874 mg/L Fe vs. 61 mg/L DOC) to the more established size separation using ultrafiltration (1285 mg/L Fe vs. 91 mg/L DOC). Cation exchange Donnan membranes were also examined: while highly selective (2555 mg/L Fe vs. 29 mg/L DOC, 88:1 selectivity), the low pH of the recovered ferric solution impaired subsequent treatment performance. The application of powdered activated carbon (PAC) to ultrafiltration or alkali pre-treated sludge, dosed at 80 mg/mg DOC, reduced recovered ferric DOC contamination to water quality parameters. Several PAC-polished recovered coagulants provided the same or improved DOC and turbidity removal as virgin coagulant, as well as demonstrating the potential to reduce disinfection byproducts and regulated metals to levels comparable to that attained from virgin material. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Optimum coagulant forecasting by modeling jar test experiments using ANNs

    Science.gov (United States)

    Haghiri, Sadaf; Daghighi, Amin; Moharramzadeh, Sina

    2018-01-01

    Currently, the proper utilization of water treatment plants and optimizing their use is of particular importance. Coagulation and flocculation in water treatment are the common ways through which the use of coagulants leads to instability of particles and the formation of larger and heavier particles, resulting in improvement of sedimentation and filtration processes. Determination of the optimum dose of such a coagulant is of particular significance. A high dose, in addition to adding costs, can cause the sediment to remain in the filtrate, a dangerous condition according to the standards, while a sub-adequate dose of coagulants can result in the reducing the required quality and acceptable performance of the coagulation process. Although jar tests are used for testing coagulants, such experiments face many constraints with respect to evaluating the results produced by sudden changes in input water because of their significant costs, long time requirements, and complex relationships among the many factors (turbidity, temperature, pH, alkalinity, etc.) that can influence the efficiency of coagulant and test results. Modeling can be used to overcome these limitations; in this research study, an artificial neural network (ANN) multi-layer perceptron (MLP) with one hidden layer has been used for modeling the jar test to determine the dosage level of used coagulant in water treatment processes. The data contained in this research have been obtained from the drinking water treatment plant located in Ardabil province in Iran. To evaluate the performance of the model, the mean squared error (MSE) and correlation coefficient (R2) parameters have been used. The obtained values are within an acceptable range that demonstrates the high accuracy of the models with respect to the estimation of water-quality characteristics and the optimal dosages of coagulants; so using these models will allow operators to not only reduce costs and time taken to perform experimental jar tests

  1. Prioritized Contact Transport Stream

    Science.gov (United States)

    Hunt, Walter Lee, Jr. (Inventor)

    2015-01-01

    A detection process, contact recognition process, classification process, and identification process are applied to raw sensor data to produce an identified contact record set containing one or more identified contact records. A prioritization process is applied to the identified contact record set to assign a contact priority to each contact record in the identified contact record set. Data are removed from the contact records in the identified contact record set based on the contact priorities assigned to those contact records. A first contact stream is produced from the resulting contact records. The first contact stream is streamed in a contact transport stream. The contact transport stream may include and stream additional contact streams. The contact transport stream may be varied dynamically over time based on parameters such as available bandwidth, contact priority, presence/absence of contacts, system state, and configuration parameters.

  2. Host defense peptides of thrombin modulate inflammation and coagulation in endotoxin-mediated shock and Pseudomonas aeruginosa sepsis.

    Science.gov (United States)

    Kalle, Martina; Papareddy, Praveen; Kasetty, Gopinath; Mörgelin, Matthias; van der Plas, Mariena J A; Rydengård, Victoria; Malmsten, Martin; Albiger, Barbara; Schmidtchen, Artur

    2012-01-01

    Gram-negative sepsis is accompanied by a disproportionate innate immune response and excessive coagulation mainly induced by endotoxins released from bacteria. Due to rising antibiotic resistance and current lack of other effective treatments there is an urgent need for new therapies. We here present a new treatment concept for sepsis and endotoxin-mediated shock, based on host defense peptides from the C-terminal part of human thrombin, found to have a broad and inhibitory effect on multiple sepsis pathologies. Thus, the peptides abrogate pro-inflammatory cytokine responses to endotoxin in vitro and in vivo. Furthermore, they interfere with coagulation by modulating contact activation and tissue factor-mediated clotting in vitro, leading to normalization of coagulation responses in vivo, a previously unknown function of host defense peptides. In a mouse model of Pseudomonas aeruginosa sepsis, the peptide GKY25, while mediating a modest antimicrobial effect, significantly inhibited the pro-inflammatory response, decreased fibrin deposition and leakage in the lungs, as well as reduced mortality. Taken together, the capacity of such thrombin-derived peptides to simultaneously modulate bacterial levels, pro-inflammatory responses, and coagulation, renders them attractive therapeutic candidates for the treatment of invasive infections and sepsis.

  3. Host defense peptides of thrombin modulate inflammation and coagulation in endotoxin-mediated shock and Pseudomonas aeruginosa sepsis.

    Directory of Open Access Journals (Sweden)

    Martina Kalle

    Full Text Available Gram-negative sepsis is accompanied by a disproportionate innate immune response and excessive coagulation mainly induced by endotoxins released from bacteria. Due to rising antibiotic resistance and current lack of other effective treatments there is an urgent need for new therapies. We here present a new treatment concept for sepsis and endotoxin-mediated shock, based on host defense peptides from the C-terminal part of human thrombin, found to have a broad and inhibitory effect on multiple sepsis pathologies. Thus, the peptides abrogate pro-inflammatory cytokine responses to endotoxin in vitro and in vivo. Furthermore, they interfere with coagulation by modulating contact activation and tissue factor-mediated clotting in vitro, leading to normalization of coagulation responses in vivo, a previously unknown function of host defense peptides. In a mouse model of Pseudomonas aeruginosa sepsis, the peptide GKY25, while mediating a modest antimicrobial effect, significantly inhibited the pro-inflammatory response, decreased fibrin deposition and leakage in the lungs, as well as reduced mortality. Taken together, the capacity of such thrombin-derived peptides to simultaneously modulate bacterial levels, pro-inflammatory responses, and coagulation, renders them attractive therapeutic candidates for the treatment of invasive infections and sepsis.

  4. Removal of Dye in Wastewater by Adsorption-Coagulation Combined System with Hibiscus sabdariffa as the Coagulant

    Directory of Open Access Journals (Sweden)

    Hoong Ho Nicholas Jian

    2018-01-01

    Full Text Available The conventional process to treat dye wastewater is the physicochemical treatment such as coagulation, flocculation and adsorption process. A new approach has been demonstrated to treat Congo red dye wastewater, which is the adsorption-coagulation hybrid process. Natural coagulant extracted from Hibiscus sabdariffa seeds is used as the coagulant while activated carbon is used as the adsorbent in this case study. The objective of this experiment is to study the significant factors that will affect the efficiency of dye removal. Then, the optimum conditions for the hybrid process is determined using Respond Surface Methodology (RSM. The variables are pH, initial dye concentration, coagulant dosage and adsorbent dosage while the response of experiment is the dye removal percentage. A three-level and four-variable Box-Behnken design (BBD is used for the RSM. A total of 27 sets of experimental results is required to determine the optimum conditions. Jar test is used to conduct the experiment with the addition of coagulant and adsorbent simultaneously. Based on the regression model analysis and ANOVA, the highly significant factors that contribute to the dye removal efficiency through adsorption-coagulation hybrid process are pH of solution and initial dye concentration. The RSM results shows that the optimised process parameters for adsorption-coagulation hybrid process with Hibiscus sabdariffa seeds as the coagulant and activated carbon as the adsorbent are pH 2, initial dye concentration of 385 ppm, coagulant dosage of 209 mg/L and adsorbent dosage of 150 mg/L. The dye removal reaches up to 96.67% under optimum parameters.

  5. Effects on coagulation factor production following primary hepatomitogen-induced direct hyperplasia.

    Science.gov (United States)

    Tatsumi, Kohei; Ohashi, Kazuo; Taminishi, Sanae; Takagi, Soichi; Utoh, Rie; Yoshioka, Akira; Shima, Midori; Okano, Teruo

    2009-11-14

    To investigate the molecular mechanisms involved in coagulation factor expression and/or function during direct hyperplasia (DH)-mediated liver regeneration. Direct hyperplasia-mediated liver regeneration was induced in female C57BL/6 mice by administering 1,4-bis[2-(3,5-dichloropyridyloxy)] benzene (TCPOBOP), a representative hepatomitogen. Mice were weighed and sacrificed at various time points [Day 0 (D0: prior to injection), 3 h, D1, D2, D3, and D10] after TCPOBOP administration to obtain liver and blood samples. Using the RNA samples extracted from the liver, a comprehensive analysis was performed on the hepatic gene expression profiling of coagulation-related factors by real-time RT-PCR (fibrinogen, prothrombin, factors V, VII, VIII, IX, X, XI, XII, XIIIbeta, plasminogen, antithrombin, protein C, protein S, ADAMTS13, and VWF). The corresponding plasma levels of coagulation factors (fibrinogen, prothrombin, factors V, VII, VIII, IX, X, XI, XII, XIII, and VWF) were also analyzed and compared with their mRNA levels. Gavage administration of TCPOBOP (3 mg/kg body weight) resulted in a marked and gradual increase in the weight of the mouse livers relative to the total body weight to 220% by D10 relative to the D0 (control) ratios. At the peak of liver regeneration (D1 and D2), the gene expression levels for most of the coagulation-related factors (fibrinogen, prothrombin, factors V, VII, VIII, IX, XI, XII, XIIIbeta, plasminogen, antithrombin, protein C, ADAMTS13, VWF) were found to be down-regulated in a time-dependent manner, and gradually recovered by D10 to the basal levels. Only mRNA levels of factor X and protein S failed to show any decrease during the regenerative phase. As for the plasma levels, 5 clotting factors (prothrombin, factors VIII, IX, XI, and XII) demonstrated a significant decrease (Pfactors, factor IX and factor XI showed the most dramatic decline in their activities by about 50% at D2 compared to the basal levels, and these reductions in

  6. Reducing surface water total and methyl mercury concentrations and bioavailability using a coagulation-wetland system

    Science.gov (United States)

    Kraus, T. E.; Fleck, J.; Henneberry, Y. K.; Stumpner, E. B.; Krabbenhoft, D. P.; Bachand, P.; Randall, P.

    2013-12-01

    With the recent passage of laws regulating concentrations and loads of mercury (Hg) in surface waters, there is a need to develop management practices that will reduce the export of Hg from both point and non-point sources. Coagulation with metal based salts to remove particles and dissolved organic matter (DOM) from solution is a practice commonly employed by drinking water utilities. Because dissolved Hg is associated with particles and DOM, it follows that Hg should also be removed during the coagulation process and end up associated with the organo-metal precipitate, termed flocculate (floc). The effectiveness of iron- and aluminum-based coagulants for removing both inorganic and methyl mercury (IHg and MeHg, respectively) from solution was demonstrated in laboratory studies conducted on agricultural drainage waters of the Sacramento-San Joaquin Delta: dissolved concentrations of MeHg decreased by 80% while IHg decreased by 97% following coagulation. To test the field application of this technology, samples were collected from the inflows and outflows of wetland treatment cells constructed in the central Delta of California. This replicated field experiment includes three replicates each of three inflow waters treatments: (1) iron sulfate addition, (2) polyaluminum chloride addition, and (3) untreated controls. Water entering and exiting the nine treatment cells was sampled approximately monthly over a 1-year period for total Hg and MeHg in both the dissolved and particulate aqueous phases. Initial results confirm that coagulant addition is removing Hg (total and methyl, particulate and dissolved) from solution and sequestering it in the floc. Seasonal effects on DOM concentration and other factors appear to effect whether passage through the wetland cells alters surface water dissolved organic carbon (DOC) and Hg concentrations. Related studies will examine whether the presence of the floc affects the production and fate of MeHg within the wetland cells. If

  7. Treatment of waste water by coagulation and flocculation using biomaterials

    Science.gov (United States)

    Muruganandam, L.; Saravana Kumar, M. P.; Jena, Amarjit; Gulla, Sudiv; Godhwani, Bhagesh

    2017-11-01

    The present study deals with the determination of physical and chemical parameters in the treatment process of waste water by flocculation and coagulation processes using natural coagulants and assessing their feasibility for water treatment by comparing the performance with each other and with a synthetic coagulant. Initial studies were done on the synthetic waste water to determine the optimal pH and dosage, the activity of natural coagulant, followed by the real effluent from tannery waste. The raw tannery effluent was bluish-black in colour, mildly basic in nature, with high COD 4000mg/l and turbidity in the range 700NTU, was diluted and dosed with organic coagulants, AloeVera, MoringaOleifera and Cactus (O.ficus-indica). The study observed that coagulant Moringa Oleifera of 15 mg/L dose at 6 pH gave the best reduction efficiencies for major physicochemical parameters followed by Aloe Vera and Cactus under identical conditions. The study reveals that the untreated tannery effluents can be treated with environmental confirmative naturally occurring coagulants.

  8. Local Void Fractions and Bubble Velocity in Vertical Air-Water Two-Phase Flows Measured by Needle-Contact Capacitance Probe

    Directory of Open Access Journals (Sweden)

    Shanfang Huang

    2018-01-01

    Full Text Available Multiphase flow measurements have become increasingly important in a wide range of industrial fields. In the present study, a dual needle-contact capacitance probe was newly designed to measure local void fractions and bubble velocity in a vertical channel, which was verified by digital high-speed camera system. The theoretical analyses and experiments show that the needle-contact capacitance probe can reliably measure void fractions with the readings almost independent of temperature and salinity for the experimental conditions. In addition, the trigger-level method was chosen as the signal processing method for the void fraction measurement, with a minimum relative error of −4.59%. The bubble velocity was accurately measured within a relative error of 10%. Meanwhile, dynamic response of the dual needle-contact capacitance probe was analyzed in detail. The probe was then used to obtain raw signals for vertical pipe flow regimes, including plug flow, slug flow, churn flow, and bubbly flow. Further experiments indicate that the time series of the output signals vary as the different flow regimes and are consistent with each flow structure.

  9. Distribution functions and moments in the theory of coagulation

    International Nuclear Information System (INIS)

    Pich, J.

    1990-04-01

    Different distribution functions and their moments used in the Theory of coagulation are summarized and analysed. Relations between the moments of these distribution functions are derived and the physical meaning of individual moments is briefly discussed. The time evolution of the moment of order zero (total number concentration) during the coagulation process is analysed for the general kernel of the Smoluchowski equation. On this basis the time evolution of certain physically important quantities related to this moment such as mean particle size, surface and volume as well as surface concentration is described. Equations for the half time of coagulation for the general collision frequency factor are derived. (orig.) [de

  10. Implementation of a microcontroller-based semi-automatic coagulator.

    Science.gov (United States)

    Chan, K; Kirumira, A; Elkateeb, A

    2001-01-01

    The coagulator is an instrument used in hospitals to detect clot formation as a function of time. Generally, these coagulators are very expensive and therefore not affordable by a doctors' office and small clinics. The objective of this project is to design and implement a low cost semi-automatic coagulator (SAC) prototype. The SAC is capable of assaying up to 12 samples and can perform the following tests: prothrombin time (PT), activated partial thromboplastin time (APTT), and PT/APTT combination. The prototype has been tested successfully.

  11. Feasibility of treating emulsified oily and salty wastewaters through coagulation and bio-regenerated GAC filtration.

    Science.gov (United States)

    Mancini, Giuseppe; Panzica, Michele; Fino, Debora; Cappello, Simone; Yakimov, Michail M; Luciano, Antonella

    2017-12-01

    In the present study, chemical oxygen demand (COD) removal by coagulation and packed-columns of both fresh and bioregenerated granular activated carbon (GAC) is reported as a feasible treatment for saline and oily wastewaters (slops) generated from marine oil tankers cleaning. The use of Ferric chloride (FeCl 3 ), Aluminium sulphate (Al 2 (SO 4 ) 3 ) and Polyaluminum chloride (Al 2 (OH 3 )Cl 3 ) was evaluated in the pre-treatment by coagulation of a real slop, after a de-oiling phase in a tank skimmer Comparison of coagulation process indicated that Polyaluminum chloride and Aluminium sulphate operate equally well (20-30% of COD removal) when applied at their optimal dose (40 and 90 mg/l respectively) but the latter should be preferred in order to significantly control the sludge production. The results from the column filtration tests indicated the feasibility of using the selected GAC (Filtrasorb 400 -Calgon Carbon Corporation) to achieve the respect of the discharge limits in the slops treatment with a carbon usage rate in the range 0.1-0.3 kg/m 3 of treated effluent. Moreover, biological regeneration through Alcalinovorax borkumensis SK2 was proved to be a cost-effective procedure since the reuse of spent GAC through such regeneration process for further treatment could still achieve approximately 90% of the initial sorption capacity, reducing then costs for the use of new sorbents and also the need for waste disposal. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. The Coagulation Profile of End-Stage Liver Disease and Considerations for Intraoperative Management.

    Science.gov (United States)

    Forkin, Katherine T; Colquhoun, Douglas A; Nemergut, Edward C; Huffmyer, Julie L

    2018-01-01

    The coagulopathy of end-stage liver disease results from a complex derangement in both anticoagulant and procoagulant processes. With even minor insults, cirrhotic patients experience either inappropriate bleeding or clotting, or even both simultaneously. The various phases of liver transplantation along with fluid and blood product administration may contribute to additional disturbances in coagulation. Thus, anesthetic management of patients undergoing liver transplantation to improve hemostasis and avoid inappropriate thrombosis in the perioperative environment can be challenging. To add to this challenge, traditional laboratory tests of coagulation are difficult to interpret in patients with end-stage liver disease. Viscoelastic coagulation tests such as thromboelastography (Haemonetics Corporation, Braintree, MA) and rotational thromboelastometry (TEM International, Munich, Germany) have helped to reduce transfusion of allogeneic blood products, especially fresh frozen plasma, but have also lead to the increased use of fibrinogen-containing products. In general, advancements in surgical techniques and anesthetic management have led to significant reduction in blood transfusion requirements during liver transplantation. Targeted transfusion protocols and pharmacologic prevention of fibrinolysis may further aid in the management of the complex coagulopathy of end-stage liver disease.

  13. Effect of nano-scale curvature on the intrinsic blood coagulation system

    Science.gov (United States)

    Kushida, Takashi; Saha, Krishnendu; Subramani, Chandramouleeswaran; Nandwana, Vikas; Rotello, Vincent M.

    2014-01-01

    The intrinsic coagulation activity of silica nanoparticles strongly depends on their surface curvature. Nanoparticles with higher surface curvature do not denature blood coagulation factor XII on its surface, providing a coagulation ‘silent’ surface, while nanoparticles with lower surface curvature shows denaturation and concomitant coagulation. PMID:25341004

  14. Potential Use of Polyaluminium Chloride and Tobacco Leaf as Coagulant and Coagulant Aid in Post-Treatment of Landfill Leachate

    Directory of Open Access Journals (Sweden)

    Nurfarahim Rusdizal

    2015-12-01

    Full Text Available A study was conducted to treat stabilized leachate by applying polyaluminium chloride (PAC and tobacco leaf extract as a coagulant and coagulant aid. Experimental results indicated that the tobacco leaves were positively charged. The removal rate of the chemical oxygen demand, using 1500 mg/L PAC as a sole coagulant, was approximately 63% and increased to 91% when 1000 mg/L PAC was mixed with 1000 mg/L tobacco leaf. Additionally, 1500 mg/L PAC with 250 - 1000 mg/L tobacco leaf and 54% ammoniacal nitrogen was removed, compared with only 46% reduction using 1500 mg/L with only 46% reduction.

  15. Does whole blood coagulation analysis reflect developmental haemostasis?

    DEFF Research Database (Denmark)

    Ravn, Hanne Berg; Andreasen, Jo Bønding; Hvas, Anne-Mette

    2017-01-01

    .05), but there was no sign of developmental changes in whole blood coagulation assessment when applying ROTEM, apart from clotting time in the EXTEM assay (P reach statistical significance. Citrate-anticoagulated blood showed...

  16. coagulation factors level in fresh frozen plasma in rwanda

    African Journals Online (AJOL)

    2014-02-02

    Feb 2, 2014 ... Setting: Jomo Kenyatta University of Agriculture and Technology in ... a major role in blood coagulation process. ... storage conditions and quality control prior to clinical ... instrumentation Laboratory Company USA made in.

  17. Coagulation profile in patients undergoing video-assisted thoracoscopic lobectomy

    DEFF Research Database (Denmark)

    Christensen, Thomas Decker; Vad, Henrik; Pedersen, Søren

    2017-01-01

    -, and the first two days postoperatively by standard coagulation blood test, thromboelastometry (ROTEM®) and thrombin generation. Results: Patients undergoing potential curative surgery for lung cancer were not hypercoagulable preoperatively. There was no statistically significant difference in the majority......Background: Knowledge about the impact of Low-Molecular-Weight Heparin (LMWH) on the coagulation system in patients undergoing minimal invasive lung cancer surgery is sparse. The aim of this study was to assess the effect of LMWH on the coagulation system in patients undergoing Video......-Assisted Thoracoscopic Surgery (VATS) lobectomy for primary lung cancer. Methods: Sixty-three patients diagnosed with primary lung cancer undergoing VATS lobectomy were randomized to either subcutaneous injection with dalteparin (Fragmin®) 5000 IE once daily or no intervention. Coagulation was assessed pre-, peri...

  18. Performance of Solanum incunum Linnaeus as natural coagulant ...

    African Journals Online (AJOL)

    hope&shola

    2- concentrations for the treated water conforms to the Tanzanian Standards and WHO guidelines for drinking ... that S. incunum is promising as coagulant and disinfectant product for water purification. Key words: .... light greenish blue-grey.

  19. Coagulation Factor Tests: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Coagulation Factor Assay; 156–7 p. ...

  20. Guidelines for the diagnosis and management of disseminated intravascular coagulation

    NARCIS (Netherlands)

    Levi, M. [=Marcel M.; Toh, C. H.; Thachil, J.; Watson, H. G.

    2009-01-01

    The diagnosis of disseminated intravascular coagulation (DIC) should encompass both clinical and laboratory information. The International Society for Thrombosis and Haemostasis (ISTH) DIC scoring system provides objective measurement of DIC. Where DIC is present the scoring system correlates with

  1. Bio-responsive polymer hydrogels homeostatically regulate blood coagulation.

    Science.gov (United States)

    Maitz, Manfred F; Freudenberg, Uwe; Tsurkan, Mikhail V; Fischer, Marion; Beyrich, Theresa; Werner, Carsten

    2013-01-01

    Bio-responsive polymer architectures can empower medical therapies by engaging molecular feedback-response mechanisms resembling the homeostatic adaptation of living tissues to varying environmental constraints. Here we show that a blood coagulation-responsive hydrogel system can deliver heparin in amounts triggered by the environmental levels of thrombin, the key enzyme of the coagulation cascade, which--in turn--becomes inactivated due to released heparin. The bio-responsive hydrogel quantitatively quenches blood coagulation over several hours in the presence of pro-coagulant stimuli and during repeated incubation with fresh, non-anticoagulated blood. These features enable the introduced material to provide sustainable, autoregulated anticoagulation, addressing a key challenge of many medical therapies. Beyond that, the explored concept may facilitate the development of materials that allow the effective and controlled application of drugs and biomolecules.

  2. Effects of coagulating enzyme types (commercial calf rennet ...

    African Journals Online (AJOL)

    Effects of coagulating enzyme types (commercial calf rennet, Aspergillus niger var. awamori as recombinant chymosin and rhizomucor miehei as microbial rennet) on the chemical and sensory characteristics of white pickled cheese.

  3. Effects of coagulating enzyme types (commercial calf rennet ...

    African Journals Online (AJOL)

    Aysegul

    2013-09-11

    clotting enzyme in traditional cheese-making world- wide (Fox, 1987 ... Following pre-brining, the cheeses were packaged in plastic cups (1 kg) containing ..... study the differential degradation of αs-casein by various coagulants.

  4. Hyperglycemia stimulates coagulation, whereas hyperinsulinemia impairs fibrinolysis in healthy humans

    NARCIS (Netherlands)

    Stegenga, Michiel E.; van der Crabben, Saskia N.; Levi, Marcel; de Vos, Alex F.; Tanck, Michael W.; Sauerwein, Hans P.; van der Poll, Tom

    2006-01-01

    Type 2 diabetes and insulin resistance syndromes are associated with an increased risk for cardiovascular and thrombotic complications. A disturbed balance between coagulation and fibrinolysis has been implicated in the pathogenesis hereof. To determine the selective effects of hyperglycemia and

  5. Contact Lens Care

    Science.gov (United States)

    ... Consumers Consumer Information by Audience For Women Contact Lens Care Share Tweet Linkedin Pin it More sharing ... www.fda.gov/medwatch Learn More about Contact Lens Care Other Tips on Contact Lenses Decorative Contact ...

  6. Removal of Arsenic from Drinking Water by Adsorption and Coagulation

    Science.gov (United States)

    Zhang, M.; Sugita, H.; Hara, J.; Takahashi, S.

    2013-12-01

    Removal of arsenic from drinking water has been an important issue worldwide, which has attracted greater attentions in recent years especially for supplying safe drinking water in developing countries. Although many kinds of treatment approaches that are available or applicable both in principle and practice, such as adsorption, coagulation, membrane filtration, ion exchange, biological process, electrocoagulation and so on, the first 2 approaches (i.e., adsorption and coagulation) are most promising due to the low-cost, high-efficiency, simplicity of treating systems, and thus can be practically used in developing countries. In this study, a literature survey on water quality in Bangladesh was performed to understand the ranges of arsenic concentration and pH of groundwater in Bangladesh. A series of tests were then organized and performed to investigate the effects of arsenic concentration, arsenic forms, pH, chemical compositions of the materials used for adsorption and coagulation, particle size distribution and treatment time on quality of treated water. The experimental results obtained in the study illustrated that both adsorption and coagulation can be used to effectively reduce the concentrations of either arsenic (V) or arsenic (III) from the contaminated water. Coagulation of arsenic with a magnesium-based material developed in this study can be very effective to remove arsenic, especially arsenic (V), from contaminated water with a concentration of 10 ppm to an undetectable level of 0.002 ppm by ICP analyses. Compared to arsenic (III), arsenic (V) is easier to be removed. The materials used for adsorption and coagulation in this study can remove arsenic (V) up to 9 mg/g and 6 mg/g, and arsenic (III) up to 4 mg/g and 3 mg/g, respectively, depending on test conditions and compositions of the materials being used. The control of pH during treatment can be a challenging technical issue for developing both adsorbent and coagulant. Keywords: Water Treatment

  7. Monitoring soft tissue coagulation by optical spectroscopy

    Science.gov (United States)

    Lihachev, A.; Lihacova, I.; Heinrichs, H.; Spigulis, J.; Trebst, T.; Wehner, M.

    2017-12-01

    Laser tissue welding (LTW) or laser tissue soldering (LTS) is investigated since many years for treatment of incisions, wound closure and anastomosis of vessels [1, 2]. Depending on the process, a certain temperature in the range between 65 °C to 85 °C must be reached and held for a few seconds. Care has to be taken not to overheat the tissue, otherwise necrosis or tissue carbonization may occur and will impair wound healing. Usually the temperature is monitored during the process to control the laser power [3]. This requires either bulky equipment or expensive and fragile infrared fibers to feed the temperature signal to an infrared detector. Alternatively, changes in tissue morphology can be directly observed by analysis of spectral reflectance. We investigate spectral changes in the range between 400 nm to 900 nm wavelength. Characteristic spectral changes occur when the temperature of tissue samples increase above 70 °C which is a typical setpoint value for temperature control of coagulation. We conclude that simple spectroscopy in the visible range can provide valuable information during LTS and LTW and probably replace the delicate measurement of temperature. A major advantage is that optical measurements can be performed using standard optical fibers and can be easily integrated into a surgical tool.

  8. Planetesimal formation by sweep-up coagulation

    Science.gov (United States)

    Windmark, Fredrik; Birnstiel, Til; Ormel, Chris W.; Dullemond, Cornelis P.

    2013-07-01

    The formation of planetesimals is often accredited to collisional sticking of dust grains in the protoplanetary disk. The exact process is however unknown, as collisions between larger aggregates tend to lead to fragmentation or bouncing rather than sticking. These growth barriers tend to halt the dust growth already at millimeters or centimeters in size, which is far below the kilometer-sizes that are needed for gravity to aid in the accretion. To study how far dust coagulation can proceed, we have developed a new collision model based on the latest laboratory experiments, and have used it together with a dust-size evolution code capable of resolving all grain interactions in the protoplanetary disk. We find that for the general dust population, bouncing and fragmenting collisions prevent the growth above millimeter-sizes. However, a small number of lucky particles can grow larger than the rest by only interacting at low, sticky velocities. As they grow, they become increasingly resilient to fragmentation caused by the small grains. In this way, two populations are formed: One which remains small due to the collisional barriers, and one that continues to grow by sweeping up the smaller grains around them.

  9. A Pontential Agriculture Waste Material as Coagulant Aid: Cassava Peel

    Science.gov (United States)

    Othman, N.; Abd-Rahim, N.-S.; Tuan-Besar, S.-N.-F.; Mohd-Asharuddin, S.; Kumar, V.

    2018-02-01

    All A large amount of cassava peel waste is generated annually by small and medium scale industries. This has led to a new policy of complete utilization of raw materials so that there will be little or no residue left that could pose pollution problems. Conversion of these by-products into a material that poses an ability to remove toxic pollutant would increase the market value and ultimately benefits the producers. This study investigated the characteristics of cassava peel as a coagulant aid material and optimization process using the cassava peel was explored through coagulation and flocculation. This research had highlighted that the Cassava peels contain sugars in the form of polysaccharides such as starch and holocellulose. The FTIR results revealed that amino acids containing abundant of carboxyl, hydroxyl and amino groups which has significant capabilities in removing pollutants. Whereas analysis by XRF spectrometry indicated that the CP samples contain Fe2O3 and Al2O3 which might contribute to its coagulation ability. The optimum condition allowed Cassava peel and alum removed high turbidity up to 90. This natural coagulant from cassava peel is found to be an alternative coagulant aid to reduce the usage of chemical coagulants

  10. Contribution to the development and the modelling of an ultrasonic conformable phased array transducer for the contact inspection of 3D complex geometry components; Contribution au developpement et a la modelisation d'un traducteur ultrasonore multielements conformable pour l'inspection au contact de composants a geometrie complexe 3D

    Energy Technology Data Exchange (ETDEWEB)

    Guedes, O

    2005-04-15

    With the difficulties encountered for the exploration of complex shape surfaces, particularly in nuclear industry, the ultrasonic conformable phased array transducer allows a non destructive evaluation of parts with 3D complex parts. For this, one can use the Smart Contact Transducer principle to generate an ultrasonic field by adaptive dynamic focalisation, with a matrix array composed of independent elements moulded in a soft resin. This work deals with the electro-acoustic conception, with the realization of such a prototype and with the study of it's mechanical and acoustic behaviour. The array design is defined using a radiation model adapted to the simulation of contact sources on a free surface. Once one have defined the shape of the radiating elements, a vibratory analysis using finite elements method allows the determination of the emitting structure with 1-3 piezocomposite, witch leads to the realization of emitting-receiving elements. With the measurement of the field transmitted by such elements, we deduced new hypothesis to change the model of radiation. Thus one can take into account normal and tangential stresses calculated with finite element modelling at the interface between the element and the propagation medium, to use it with the semi-analytical model. Some vibratory phenomena dealing with fluid coupling of contact transducers have been studied, and the prediction of the transverse wave radiation profile have been improved. The last part of this work deals with the realization of the first prototype of the conformable phased array transducer. For this a deformation measuring system have been developed, to determine the position of each element on real time with the displacement of the transducer on complex shape surfaces. With those positions, one can perform the calculation of the a delay law intended for the adaptive dynamic focusing of the desired ultrasonic field. The conformable phased array transducer have been characterized in

  11. Contribution to the development and the modelling of an ultrasonic conformable phased array transducer for the contact inspection of 3D complex geometry components; Contribution au developpement et a la modelisation d'un traducteur ultrasonore multielements conformable pour l'inspection au contact de composants a geometrie complexe 3D

    Energy Technology Data Exchange (ETDEWEB)

    Guedes, O

    2005-04-15

    With the difficulties encountered for the exploration of complex shape surfaces, particularly in nuclear industry, the ultrasonic conformable phased array transducer allows a non destructive evaluation of parts with 3D complex parts. For this, one can use the Smart Contact Transducer principle to generate an ultrasonic field by adaptive dynamic focalisation, with a matrix array composed of independent elements moulded in a soft resin. This work deals with the electro-acoustic conception, with the realization of such a prototype and with the study of it's mechanical and acoustic behaviour. The array design is defined using a radiation model adapted to the simulation of contact sources on a free surface. Once one have defined the shape of the radiating elements, a vibratory analysis using finite elements method allows the determination of the emitting structure with 1-3 piezocomposite, witch leads to the realization of emitting-receiving elements. With the measurement of the field transmitted by such elements, we deduced new hypothesis to change the model of radiation. Thus one can take into account normal and tangential stresses calculated with finite element modelling at the interface between the element and the propagation medium, to use it with the semi-analytical model. Some vibratory phenomena dealing with fluid coupling of contact transducers have been studied, and the prediction of the transverse wave radiation profile have been improved. The last part of this work deals with the realization of the first prototype of the conformable phased array transducer. For this a deformation measuring system have been developed, to determine the position of each element on real time with the displacement of the transducer on complex shape surfaces. With those positions, one can perform the calculation of the a delay law intended for the adaptive dynamic focusing of the desired ultrasonic field. The conformable phased array transducer have been characterized in

  12. Perspectives of transurethral robotic laser resection of the prostate: vaporization and coagulation effects with the Nd:YAG laser

    Science.gov (United States)

    Ho, Gideon; Teo, Ming Y.; Kwoh, Chee K.; Ng, Wan S.; Cheng, Wai S.

    2000-05-01

    A longer operating time and steeper learning curve in mastering the techniques for transurethral laser resection of the prostate are the main problems faced by surgeons compared to standard transurethral resection of the prostate (TURP). However, these disadvantages can be solved with the introduction of a treatment modality designed and developed based on an integrated system of computer, robotics and laser technology. In vitro experiments were carried out to determine variables affecting the vaporization and coagulation lesions, in order to identify the parameters that could optimize this modality. Human cadaveric prostate and fresh chicken breast tissues were irradiated with different parameters using continuous wave Nd:YAG laser fiber in contact with the tissue. The effects of irrigant flowrate, fiber/tissue angle of inclination, number of passes, direction, speed and power of lase on the volume of tissue vaporized and coagulated, were assessed. A non-contact optical coordinate measuring machine was used to measure the depth and width of the vaporized and coagulated lesion. Results reveal that for each directional vaporization path (forward, clockwise and counter-clockwise), power and speed of lase are the most significant parameters influencing the volume of the vaporized and coagulated lesion. Optimized values of the power and speed of lase at 100 W and 1 - 3 mm/s respectively were obtained from the experiments when the tissues were irradiated in the forward, clockwise and counter-clockwise directions. It was concluded from our study to quantify tissue removal and damage, optimized values of irradiation power and speed could be obtained and implemented in the procedure of transurethral robotic laser resection of the prostate.

  13. Enhanced WWTP effluent organic matter removal in hybrid ozonation-coagulation (HOC) process catalyzed by Al-based coagulant

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Xin [School of Environmental and Municipal Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi Province, 710055 (China); Jin, Pengkang, E-mail: pkjin@hotmail.com [School of Environmental and Municipal Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi Province, 710055 (China); Hou, Rui [School of Environmental and Municipal Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi Province, 710055 (China); Yang, Lei [Department of Materials Science and Engineering, Monash University, Clayton, VIC, 3800 (Australia); Wang, Xiaochang C., E-mail: xcwang@xauat.edu.cn [School of Environmental and Municipal Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi Province, 710055 (China)

    2017-04-05

    Highlights: • A novel HOC process was firstly put forward to apply in wastewater reclamation. • Interactions between ozone and Al-based coagulants was found in the HOC process. • Ozonation can be catalyzed and enhanced by Al-based coagulants in the HOC process. • HOC process showed better organics removal than pre-ozonation-coagulation process. - Abstract: A novel hybrid ozonation-coagulation (HOC) process was developed for application in wastewater reclamation. In this process, ozonation and coagulation occurred simultaneously within a single unit. Compared with the conventional pre-ozonation-coagulation process, the HOC process exhibited much better performance in removing dissolved organic matters. In particular, the maximal organic matters removal efficiency was obtained at the ozone dosage of 1 mgO{sub 3}/mg DOC at each pH value (pH 5, 7 and 9). In order to interpret the mechanism of the HOC process, ozone decomposition was monitored. The results indicated that ozone decomposed much faster in the HOC process. Moreover, by using the reagent of O{sub 3}-resistant hydroxyl radical (·OH) probe compound, para-chlorobenzoic acid (pCBA), and electron paramagnetic resonance (EPR) analysis, it was observed that the HOC process generated higher content of ·OH compared with pre-ozonation process. This indicates that the ·OH oxidation reaction as the key step can be catalyzed and enhanced by Al-based coagulants and their hydrolyzed products in this developed process. Thus, based on the catalytic effects of Al-based coagulants on ozonation, the HOC process provides a promising alternative to the conventional technology for wastewater reclamation in terms of higher efficiency.

  14. Enhanced algae removal by Ti-based coagulant: comparison with conventional Al- and Fe-based coagulants.

    Science.gov (United States)

    Xu, Jie; Zhao, Yanxia; Gao, Baoyu; Zhao, Qian

    2018-05-01

    The water eutrophication caused by cyanobacteria seasonally proliferates, which is a hot potato to be resolved for water treatment plants. This study firstly investigated coagulation performance of titanium tetrachloride (TiCl 4 ) for Microcystis aeruginosa synthetic water treatment. Results show complete algal cell removal by TiCl 4 coagulation without damage to cell membrane integrity even under harsh conditions; 60 mg/L TiCl 4 was effective in removing the microcystins up to 85%. Furthermore, besides having stronger UV 254 removal capability and the higher removal of fluorescent substances over Al- and Fe-based coagulants, TiCl 4 coagulant required more compact coagulation and sedimentation tanks due to its significantly improved floc growth and sedimentation speed. Meanwhile, its' short hydraulic retention time avoided algal cell breakage and subsequent algal organic matter release. Microcystin concentrations were kept at a low level during sludge storage period, indicating that the TiCl 4 flocs could prevent algal cells from natural lysis. To facilitate water recycling without secondary contamination, the algae-containing sludge after TiCl 4 coagulation ought to be disposed within 12 days at 20 °C and 8 days at 35 °C.

  15. Blood coagulation abnormalities in multibacillary leprosy patients.

    Science.gov (United States)

    Silva, Débora Santos da; Teixeira, Lisandra Antonia Castro; Beghini, Daniela Gois; Ferreira, André Teixeira da Silva; Pinho, Márcia de Berredo Moreira; Rosa, Patricia Sammarco; Ribeiro, Marli Rambaldi; Freire, Monica Di Calafiori; Hacker, Mariana Andrea; Nery, José Augusto da Costa; Pessolani, Maria Cristina Vidal; Tovar, Ana Maria Freire; Sarno, Euzenir Nunes; Perales, Jonas; Bozza, Fernando Augusto; Esquenazi, Danuza; Monteiro, Robson Queiroz; Lara, Flavio Alves

    2018-03-01

    Leprosy is a chronic dermato-neurological disease caused by Mycobacterium leprae infection. In 2016, more than 200,000 new cases of leprosy were detected around the world, representing the most frequent cause of infectious irreversible deformities and disabilities. In the present work, we demonstrate a consistent procoagulant profile on 40 reactional and non-reactional multibacillary leprosy patients. A retrospective analysis in search of signs of coagulation abnormalities among 638 leprosy patients identified 35 leprosy patients (5.48%) which displayed a characteristic lipid-like clot formed between blood clot and serum during serum harvesting, herein named 'leprosum clot'. Most of these patients (n = 16, 45.7%) belonged to the lepromatous leprosy pole of the disease. In addition, formation of the leprosum clot was directly correlated with increased plasma levels of soluble tissue factor and von Willebrand factor. High performance thin layer chromatography demonstrated a high content of neutral lipids in the leprosum clot, and proteomic analysis demonstrated that the leprosum clot presented in these patients is highly enriched in fibrin. Remarkably, differential 2D-proteomics analysis between leprosum clots and control clots identified two proteins present only in leprosy patients clots: complement component 3 and 4 and inter-alpha-trypsin inhibitor family heavy chain-related protein (IHRP). In agreement with those observations we demonstrated that M. leprae induces hepatocytes release of IHRP in vitro. We demonstrated that leprosy MB patients develop a procoagulant status due to high levels of plasmatic fibrinogen, anti-cardiolipin antibodies, von Willebrand factor and soluble tissue factor. We propose that some of these components, fibrinogen for example, presents potential as predictive biomarkers of leprosy reactions, generating tools for earlier diagnosis and treatment of these events.

  16. Blood coagulation abnormalities in multibacillary leprosy patients.

    Directory of Open Access Journals (Sweden)

    Débora Santos da Silva

    2018-03-01

    Full Text Available Leprosy is a chronic dermato-neurological disease caused by Mycobacterium leprae infection. In 2016, more than 200,000 new cases of leprosy were detected around the world, representing the most frequent cause of infectious irreversible deformities and disabilities.In the present work, we demonstrate a consistent procoagulant profile on 40 reactional and non-reactional multibacillary leprosy patients. A retrospective analysis in search of signs of coagulation abnormalities among 638 leprosy patients identified 35 leprosy patients (5.48% which displayed a characteristic lipid-like clot formed between blood clot and serum during serum harvesting, herein named 'leprosum clot'. Most of these patients (n = 16, 45.7% belonged to the lepromatous leprosy pole of the disease. In addition, formation of the leprosum clot was directly correlated with increased plasma levels of soluble tissue factor and von Willebrand factor. High performance thin layer chromatography demonstrated a high content of neutral lipids in the leprosum clot, and proteomic analysis demonstrated that the leprosum clot presented in these patients is highly enriched in fibrin. Remarkably, differential 2D-proteomics analysis between leprosum clots and control clots identified two proteins present only in leprosy patients clots: complement component 3 and 4 and inter-alpha-trypsin inhibitor family heavy chain-related protein (IHRP. In agreement with those observations we demonstrated that M. leprae induces hepatocytes release of IHRP in vitro.We demonstrated that leprosy MB patients develop a procoagulant status due to high levels of plasmatic fibrinogen, anti-cardiolipin antibodies, von Willebrand factor and soluble tissue factor. We propose that some of these components, fibrinogen for example, presents potential as predictive biomarkers of leprosy reactions, generating tools for earlier diagnosis and treatment of these events.

  17. Effects of surface chemistry on coagulation of submicron iron oxide particles (α-Fe_2O_3) in water

    OpenAIRE

    Liang, Liyuan

    1988-01-01

    Particles in the colloidal size range, i.e. smaller than 10^(-6) meter, are of interest in environmental science and many other fields of science and engineering. Since aqueous oxide particles have high specific surface areas they adsorb ions and molecules from water, and may remain stable in the aqueous phase with respect to coagulation. Submicron particles collide as a result of their thermal energy, and the effective collision rate is slowed by electric repulsion forces. A key to understan...

  18. A quantitative comparison between electrocoagulation and chemical coagulation for boron removal from boron-containing solution

    International Nuclear Information System (INIS)

    Yilmaz, A. Erdem; Boncukcuoglu, Recep; Kocakerim, M. Muhtar

    2007-01-01

    This paper provides a quantitative comparison of electrocoagulation and chemical coagulation approaches based on boron removal. Electrocoagulation process delivers the coagulant in situ as the sacrificial anode corrodes, due to a fixed current density, while the simultaneous evolution of hydrogen at the cathode allows for pollutant removal by flotation. By comparison, conventional chemical coagulation typically adds a salt of the coagulant, with settling providing the primary pollutant removal path. Chemical coagulation was carried out via jar tests using aluminum chloride. Comparison was done with the same amount of coagulant between electrocoagulation and chemical coagulation processes. Boron removal obtained was higher with electrocoagulation process. In addition, it was seen that chemical coagulation has any effect for boron removal from boron-containing solution. At optimum conditions (e.g. pH 8.0 and aluminum dose of 7.45 g/L), boron removal efficiencies for electrocoagulation and chemical coagulation were 94.0% and 24.0%, respectively

  19. A quantitative comparison between electrocoagulation and chemical coagulation for boron removal from boron-containing solution

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, A. Erdem [Atatuerk University, Faculty of Engineering, Department of Environmental Engineering, 25240 Erzurum (Turkey)], E-mail: aerdemy@atauni.edu.tr; Boncukcuoglu, Recep [Atatuerk University, Faculty of Engineering, Department of Environmental Engineering, 25240 Erzurum (Turkey); Kocakerim, M. Muhtar [Atatuerk University, Faculty of Engineering, Department of Chemical Engineering, 25240 Erzurum (Turkey)

    2007-10-22

    This paper provides a quantitative comparison of electrocoagulation and chemical coagulation approaches based on boron removal. Electrocoagulation process delivers the coagulant in situ as the sacrificial anode corrodes, due to a fixed current density, while the simultaneous evolution of hydrogen at the cathode allows for pollutant removal by flotation. By comparison, conventional chemical coagulation typically adds a salt of the coagulant, with settling providing the primary pollutant removal path. Chemical coagulation was carried out via jar tests using aluminum chloride. Comparison was done with the same amount of coagulant between electrocoagulation and chemical coagulation processes. Boron removal obtained was higher with electrocoagulation process. In addition, it was seen that chemical coagulation has any effect for boron removal from boron-containing solution. At optimum conditions (e.g. pH 8.0 and aluminum dose of 7.45 g/L), boron removal efficiencies for electrocoagulation and chemical coagulation were 94.0% and 24.0%, respectively.

  20. Effect of nano-scale curvature on the intrinsic blood coagulation system

    Science.gov (United States)

    Kushida, Takashi; Saha, Krishnendu; Subramani, Chandramouleeswaran; Nandwana, Vikas; Rotello, Vincent M.

    2014-11-01

    The intrinsic coagulation activity of silica nanoparticles strongly depends on their surface curvature. Nanoparticles with higher surface curvature do not denature blood coagulation factor XII on its surface, providing a coagulation `silent' surface, while nanoparticles with lower surface curvature show denaturation and concomitant coagulation.The intrinsic coagulation activity of silica nanoparticles strongly depends on their surface curvature. Nanoparticles with higher surface curvature do not denature blood coagulation factor XII on its surface, providing a coagulation `silent' surface, while nanoparticles with lower surface curvature show denaturation and concomitant coagulation. Electronic supplementary information (ESI) available: Physical properties and scanning electron micrographs (SEM) of silica NPs, intrinsic coagulation activity after 3 h. See DOI: 10.1039/c4nr04128c

  1. Occupational contact urticaria and protein contact dermatitis.

    Science.gov (United States)

    Doutre, Marie-Sylvie

    2005-01-01

    Irritant dermatitis and eczema are the most prevalent occupational skin diseases. Less common are immediate contact reactions such as contact urticaria and protein contact dermatitis. Occupational contact urticaria can be subdivided into two categories, immunological and non immunological. However, some agents can induce these two types of reactions. Contact urticaria to natural rubber latex is particularly frequent among health care personnel, but contact urticaria to a wide variety of other substances occurs in many other occupations. Among those at risk are cooks, bakers, butchers, restaurant personnel, veterinarians, hairdressers, florists, gardeners, and forestry workers. Protein contact dermatitis in some of these occupations is caused principally by proteins of animal or plant origin, especially among individuals with a history of atopic dermatitis. Diagnosis requires careful interrogation, clinical examination and skin tests (open tests and prick tests with immediate lecture) to identify a particular contact allergen.

  2. Expression of CD73 slows down migration of skin dendritic cells, affecting the sensitization phase of contact hypersensitivity reactions in mice.

    Science.gov (United States)

    Neuberger, A; Ring, S; Silva-Vilches, C; Schrader, J; Enk, A; Mahnke, K

    2017-09-01

    Application of haptens to the skin induces release of immune stimulatory ATP into the extracellular space. This "danger" signal can be converted to immunosuppressive adenosine (ADO) by the action of the ectonucleotidases CD39 and CD73, expressed by skin and immune cells. Thus, the expression and regulation of CD73 by skin derived cells may have crucial influence on the outcome of contact hypersensitivity (CHS) reactions. To investigate the role of CD73 expression during 2,4,6-trinitrochlorobenzene (TNCB) induced CHS reactions. Wild type (wt) and CD73 deficient mice were subjected to TNCB induced CHS. In the different mouse strains the resulting ear swelling reaction was recorded along with a detailed phenotypic analysis of the skin migrating subsets of dendritic cells (DC). In CD73 deficient animals the motility of DC was higher as compared to wt animals and in particular after sensitization we found increased migration of Langerin + DC from skin to draining lymph nodes (LN). In the TNCB model this led to a stronger sensitization as indicated by increased frequency of interferon-γ producing T cells in the LN and an increased ear thickness after challenge. CD73 derived ADO production slows down migration of Langerin + DC from skin to LN. This may be a crucial mechanism to avoid over boarding immune reactions against haptens. Copyright © 2017 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.

  3. Contact system activation and high thrombin generation in hyperthyroidism.

    Science.gov (United States)

    Kim, Namhee; Gu, Ja-Yoon; Yoo, Hyun Ju; Han, Se Eun; Kim, Young Il; Nam-Goong, Il Sung; Kim, Eun Sook; Kim, Hyun Kyung

    2017-05-01

    Hyperthyroidism is associated with increased thrombotic risk. As contact system activation through formation of neutrophil extracellular traps (NET) has emerged as an important trigger of thrombosis, we hypothesized that the contact system is activated along with active NET formation in hyperthyroidism and that their markers correlate with disease severity. In 61 patients with hyperthyroidism and 40 normal controls, the levels of coagulation factors (fibrinogen, and factor VII, VIII, IX, XI and XII), D-dimer, thrombin generation assay (TGA) markers, NET formation markers (histone-DNA complex, double-stranded DNA and neutrophil elastase) and contact system markers (activated factor XII (XIIa), high-molecular-weight kininogen (HMWK), prekallikrein and bradykinin) were measured. Patients with hyperthyroidism showed higher levels of fibrinogen (median (interquartile range), 315 (280-344) vs 262 (223-300), P  = 0.001), D-dimer (103.8 (64.8-151.5) vs 50.7 (37.4-76.0), P  hyperthyroidism's contribution to coagulation and contact system activation. Free T4 was significantly correlated with factors VIII and IX, D-dimer, double-stranded DNA and bradykinin. This study demonstrated that contact system activation and abundant NET formation occurred in the high thrombin generation state in hyperthyroidism and were correlated with free T4 level. © 2017 European Society of Endocrinology.

  4. WATER PURIFICATION BY COAGULATION UNDER THE INFLUENCE OF ULTRASONIC FIELD

    Directory of Open Access Journals (Sweden)

    Vikulina Vera Borisovna

    2016-03-01

    Full Text Available The authors carried out experiments on the in-fluence of ultrasound on the subsidence of suspended materials. The efficiency of coagulation process in wa-ter purification in ultrasound field is estimated. The influence of ultrasound on the water with suspended materials before introducing coagulant was a condition of the experiment. The magnetostriction method for obtaining ultrasound oscillations with the help of ultra-sound generator of batch production was applied. The samples were chosen and the coagulation process was controlled using standard procedures. The experimental data was obtained which estimate the efficiency in-crease in the subsidence of suspended materials de-pending on the duration of ultrasound processing. Dur-ing one minute of ultrasound processing the following results were obtained: the subsidence efficiency in-creased by 25.83 % in case of coagulant share Al2O3 2.5 mg/l; the subsidence efficiency increased by 23.70 % in case of coagulant share Al2O3 5.0 mg/l.

  5. Vegetable coagulants as alternative for treatment of wastewater in Mexico

    Directory of Open Access Journals (Sweden)

    Servando López-León

    2017-11-01

    Full Text Available This review addresses the various properties of natural coagulants, water, the chemical substance essential for life and the ideal solvent for a large number of compounds, it is commonly used with domestic, commercial and industrial purposes. After its use, it presents sewage to be retired before use it once again. To remove pollutant, water is subject to different physical, chemical and biological processes. Here, the clarification process uses aluminum and iron materials to remove the solids present; these materials are reported as health hazardous and toxic. In Mexico, regulatory frame work stablish that treated wastewater should do not exceed 0.2 mg/L of aluminum even though has been reported an increased risk of Alzheimer's in populations when water exceeds 0.1 mg/L. Natural coagulants have showed coagulation properties when are used in the clarification process, proven its advantages over traditional ones; such as low cost, good coagulant properties and safe health and non-toxic properties. Here, we enlist some vegetable species as alternatives to the traditional based on aluminum and iron. Additionally, these species are known to have origins on Mexico or being present extensively in the territory, making possible to think about them as alternative coagulants in the clarification process of the wastewater treatment process.

  6. The Effect of LiCl and Coagulation Bath Temperature on the Structure and Performance of PVDF Membranes

    Directory of Open Access Journals (Sweden)

    Marzieh Sedaghat

    2015-09-01

    Full Text Available Polyvinylidene fluoride (PVDF membranes are widely used in microfiltration and ultrafiltration processes for their excellent mechanical and chemical resistance and thermal stability in comparison with other polymeric membranes. Non-solvent induced phase separation (NIPS is the most important method by which the PVDF membranes are prepared. The structure of the membranes prepared by NIPS method depends on different parameters including the concentration of the polymer solution, polymer molecular weight, the composition and temperature of coagulation bath, type of solvent and the presence of additives in the initial solution. In the present work, the effects of coagulation bath temperature and LiCl content of the dope solution were studied with respect to the structure and performance of PVDF membranes. N-Methyl-2-pyrrolidone and water were used as solvent and coagulation bath, respectively. A set of analytical techniques including: scanning electron microscopy, mechanical test, pure water permeability and mean pore radius of pores was used to characterize the membranes. Moreover, the separation of humic acid, a main biological contaminant in surface water resources, was studied to determine membranes performance. The results show that at constant coagulation bath temperature, presence of LiCl in the dope solution increased the number as well as the mean pore radius of the pores at the surface of membranes and consequently, pure water permeability of the membranes was increased, whereas, the mechanical strength and humic acid rejection of the membranes were dropped. Moreover, at a constant content of LiCl, increasing the coagulation bath temperature decreased the size of macrovoids so that the mechanical strength as well as humic acid rejection of the membranes was increased.

  7. Detection of tissue coagulation by decorrelation of ultrasonic echo signals in cavitation-enhanced high-intensity focused ultrasound treatment.

    Science.gov (United States)

    Yoshizawa, Shin; Matsuura, Keiko; Takagi, Ryo; Yamamoto, Mariko; Umemura, Shin-Ichiro

    2016-01-01

    A noninvasive technique to monitor thermal lesion formation is necessary to ensure the accuracy and safety of high-intensity focused ultrasound (HIFU) treatment. The purpose of this study is to ultrasonically detect the tissue change due to thermal coagulation in the HIFU treatment enhanced by cavitation microbubbles. An ultrasound imaging probe transmitted plane waves at a center frequency of 4.5 MHz. Ultrasonic radio-frequency (RF) echo signals during HIFU exposure at a frequency of 1.2 MHz were acquired. Cross-correlation coefficients were calculated between in-phase and quadrature (IQ) data of two B-mode images with an interval time of 50 and 500 ms for the estimation of the region of cavitation and coagulation, respectively. Pathological examination of the coagulated tissue was also performed to compare with the corresponding ultrasonically detected coagulation region. The distribution of minimum hold cross-correlation coefficient between two sets of IQ data with 50-ms intervals was compared with a pulse inversion (PI) image. The regions with low cross-correlation coefficients approximately corresponded to those with high brightness in the PI image. The regions with low cross-correlation coefficients in 500-ms intervals showed a good agreement with those with significant change in histology. The results show that the regions of coagulation and cavitation could be ultrasonically detected as those with low cross-correlation coefficients between RF frames with certain intervals. This method will contribute to improve the safety and accuracy of the HIFU treatment enhanced by cavitation microbubbles.

  8. Geometry-Dependent Electrostatics near Contact Lines

    International Nuclear Information System (INIS)

    Chou, Tom

    2001-01-01

    Long-ranged electrostatic interactions in electrolytes modify contact angles on charged substrates in a scale and geometry-dependent manner. For angles measured at scales smaller than the typical Debye screening length, the wetting geometry near the contact line must be explicitly considered. Using variational and asymptotic methods, we derive new transcendental equations for the contact angle as functions of the electrostatic potential only at the three phase contact line. Analytic expressions are found in certain limits and compared with predictions for contact angles measured with lower resolution. An estimate for electrostatic contributions to line tension is also given

  9. Comparison of Moringa stenopetala seed extract as a clean coagulant with Alum and Moringa stenopetala-Alum hybrid coagulant to remove direct dye from Textile Wastewater.

    Science.gov (United States)

    Dalvand, Arash; Gholibegloo, Elham; Ganjali, Mohammad Reza; Golchinpoor, Najmeh; Khazaei, Mohammad; Kamani, Hossein; Hosseini, Sara Sadat; Mahvi, Amir Hossein

    2016-08-01

    In this study, the efficiency of Moringa stenopetala seed extract was compared with alum and M. stenopetala-alum hybrid coagulant to remove Direct Red 23 azo dye from textile wastewater. The effects of parameters such as pH, coagulant dose, type of salt used for the extraction of coagulant and initial dye concentration on dye removal efficiency were investigated. Moreover, the existing functional groups on the structure of M. stenopetala coagulant (MSC) were determined by Fourier transform infrared spectroscopy, and the morphology of sludge produced by MSC, alum, and hybrid coagulant was characterized by scanning electron microscopy. Ninhydrin test was also used to determine the quantity of primary amines in the MSC and Moringa oleifera coagulant (MOC). According to the results, with increasing the coagulant dose and decreasing the initial dye concentration, dye removal efficiency has increased. The maximum dye removal of 98.5, 98.2, and 98.3 % were obtained by using 240, 120, and 80 mg/L MSC, alum and hybrid coagulant at pH 7, respectively. The results also showed MSC was much more effective than MOC for dye removal. The volume of sludge produced by MSC was one fourth and half of those produced by alum and hybrid coagulant, respectively. Based on the results, hybrid coagulant was the most efficient coagulant for direct dye removal from colored wastewater.

  10. Ozonation and/or Coagulation - Ceramic Membrane Hybrid for Filtration of Impaired-Quality Source Waters

    KAUST Repository

    Ha, Changwon

    2013-09-01

    When microfiltration (MF) and ultrafiltration (UF) membranes are applied for drinking water treatment/wastewater reuse, membrane fouling is an evitable problem, causing the loss of productivity over time. Polymeric membranes have been often reported to experience rapid and/or problematical fouling, restraining sustainable operation. Ceramic membranes can be effectively employed to treat impaired-quality source waters due to their inherent robustness in terms of physical and chemical stability. This research aimed to identify the effects of coagulation and/or ozonation on ceramic membrane filtration for seawater and wastewater (WW) effluent. Two different types of MF and UF ceramic membranes obtained by sintering (i.e., TAMI made of TiO2+ZrO2) and anodic oxidation process (i.e., AAO made of Al2O3) were employed for bench-scale tests. Precoagulation was shown to play an important role in both enhancing membrane filterability and natural organic matter (NOM) removal efficacy for treating a highorganic surface water. The most critical factors were found to be pH and coagulant dosage with the highest efficiency resulting under low pH and high coagulant dose. Due to the ozone-resistance nature of the ceramic membranes, preozonation allowed the ceramic membranes to be operated at higher flux, especially leading to significant flux improvement when treating seawater in the presence of calcium and magnesium. 4 Dissolved ozone in contact with the TAMI ceramic membrane surface accelerated the formation of hydroxyl (˙OH) radicals in WW effluent treatment. Flux restoration of both ceramic membranes, fouled with seawater and WW effluent, was efficiently achieved by high backwash (BW) pressure and ozone in chemically enhanced backwashing (CEB). Ceramic membranes exhibited a pH-dependent permeate flux while filtering WW effluent, showing reduced fouling with increased pH. On the other hand, for filtering seawater, differences in permeate flux between the two membranes was

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  13. Removal Natural Organic Matter (NOM in Peat Water from Wetland Area by Coagulation-Ultrafiltration Hybrid Process with Pretreatment Two-Stage Coagulation

    Directory of Open Access Journals (Sweden)

    Mahmud Mahmud

    2013-11-01

    Full Text Available The primary problem encountered in the application of membrane technology was membrane fouling. During this time, hybrid process by coagulation-ultrafiltration in drinking water treatment that has been conducted by some research, using by one-stage coagulation. The goal of this research was to investigate the effect of two-stage coagulation as a pretreatment towards performance of the coagulation-ultrafiltration hybrid process for removal NOM in the peat water. Coagulation process, either with the one-stage or two-stage coagulation was very good in removing charge hydrophilic fraction, i.e. more than 98%. NOM fractions of the peat water, from the most easily removed by the two-stage coagulation and one-stage coagulation process was charged hydrophilic>strongly hydrophobic>weakly hydrophobic>neutral hydrophilic. The two-stage coagulation process could removed UV254 and colors with a little better than the one-stage coagulation at the optimum coagulant dose. Neutral hydrophilic fraction of peat water NOM was the most influential fraction of UF membrane fouling. The two-stage coagulation process better in removing the neutral hidrophilic fraction, while removing of the charged hydrophilic, strongly hydrophobic and weakly hydrophobic similar to the one-stage coagulation. Hybrid process by pretreatment with two-stage coagulation, beside can increased removal efficiency of UV254 and color, also can reduced fouling rate of the ultrafiltration membraneIt must not exceed 250 words, contains a brief summary of the text, covering the whole manuscript without being too elaborate on every section. Avoid any abbreviation, unless it is a common knowledge or has been previously stated.

  14. Removal Natural Organic Matter (NOM in Peat Water from Wetland Area by Coagulation-Ultrafiltration Hybrid Process with Pretreatment Two-Stage Coagulation

    Directory of Open Access Journals (Sweden)

    Mahmud Mahmud

    2016-06-01

    Full Text Available The primary problem encountered in the application of membrane technology was membrane fouling. During this time, hybrid process by coagulation-ultrafiltration in drinking water treatment that has been conducted by some research, using by one-stage coagulation. The goal of this research was to investigate the effect of two-stage coagulation as a pretreatment towards performance of the coagulation-ultrafiltration hybrid process for removal NOM in the peat water. Coagulation process, either with the one-stage or two-stage coagulation was very good in removing charge hydrophilic fraction, i.e. more than 98%. NOM fractions of the peat water, from the most easily removed by the two-stage coagulation and one-stage coagulation process was charged hydrophilic>strongly hydrophobic>weakly hydrophobic>neutral hydrophilic. The two-stage coagulation process could removed UV254 and colors with a little better than the one-stage coagulation at the optimum coagulant dose. Neutral hydrophilic fraction of peat water NOM was the most influential fraction of UF membrane fouling. The two-stage coagulation process better in removing the neutral hidrophilic fraction, while removing of the charged hydrophilic, strongly hydrophobic and weakly hydrophobic similar to the one-stage coagulation. Hybrid process by pretreatment with two-stage coagulation, beside can increased removal efficiency of UV254 and color, also can reduced fouling rate of the ultrafiltration membraneIt must not exceed 250 words, contains a brief summary of the text, covering the whole manuscript without being too elaborate on every section. Avoid any abbreviation, unless it is a common knowledge or has been previously stated.

  15. Exact results for the Boltzmann equation and Smoluchowski's coagulation equation

    International Nuclear Information System (INIS)

    Hendriks, E.M.

    1983-01-01

    Almost no analytical solutions have been found for realistic intermolecular forces, largely due to the complicated structure of the collision term which calls for the construction of simplified models, in which as many physical properties are maintained as possible. In the first three chapters of this thesis such model Boltzmann equations are studied. Only spatially homogeneous gases with isotropic distribution functions are considered. Chapter I considers transition kernels, chapter II persistent scattering models and chapter III very hard particles. The second part of this dissertation deals with Smoluchowski's coagulation equation for the size distribution function in a coagulating system, with chapters devoted to the following topics: kinetics of gelation and universality, coagulation equations with gelation and exactly soluble models of nucleation. (Auth./C.F.)

  16. Comparison of electrocoagulation and chemical coagulation for heavy metal removal

    Energy Technology Data Exchange (ETDEWEB)

    Akbal, F.; Camci, S. [Ondokuz Mayis University, Engineering Faculty, Environmental Engineering Department, Kurupelit, Samsun (Turkey)

    2010-10-15

    Copper (Cu), chromium (Cr), and nickel (Ni) removal from metal plating wastewater by electrocoagulation and chemical coagulation was investigated. Chemical coagulation was performed using either aluminum sulfate or ferric chloride, whereas electrocoagulation was done in an electrolytic cell using aluminum or iron electrodes. By chemical coagulation, Cu-, Cr-, and Ni-removal of 99.9 % was achieved with aluminum sulfate and ferric chloride dosages of 500, 1000, and 2000 mg L{sup -1}, respectively. Removal of metals by electrocoagulation was affected by the electrode material, wastewater pH, current density, number of electrodes, and electrocoagulation time. Electrocoagulation with iron electrodes at a current density of 10 mA cm{sup -2}, electrocoagulation time of 20 min, and pH 3.0 resulted in 99.9 % Cu-, 99.9 % Cr-, and 98 % Ni-removal. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  17. Exploration by radioactive fibrinogen of intrarenal coagulation phenomena. Preliminary results

    International Nuclear Information System (INIS)

    Simon, Jacques.

    1974-01-01

    The participation of fibrin deposits in kidney pathology was studied by the use of a radioactive tracer involved in the coagulation phenomenon: iodine 131-labelled fibrinogen. The isotopic exploration consists of a fibrinogen kinetics study combined with external counting over the kidney regions. The different stages of the procedure are described: separation, purification and labelling of fibrinogen; characteristics of the radioactive fibrinogen used; practical details of the examination itself; data analysis method. A chapter devoted to verifications and discussions of the procedure is followed by a report on the exploration of intrarenal coagulation phenomena in 30 kidney disease patients. In conclusion, the study of fibrinogen kinetics is considered as the most suitable method to detect local or slight intravascular coagulation phenomena. The sensitivity of the isotopic exploration is very satisfactory. The main criticism directed against this method is that the exploration is general and therefore blind [fr

  18. TRAITEMENT DES EAUX USEES PAR COAGULATION-FLOCULATION EN UTILISANT LE SULFATE D’ALUMINIUM COMME COAGULANT

    Directory of Open Access Journals (Sweden)

    Nora SEGHAIRI

    2017-12-01

    Full Text Available Domestic wastewater treatment by coagulation-flocculation is widely used internationally. This treatment reduces color and turbidity, indicating organic and inorganic contaminants, but at acceptable levels for treated waste water discharged into the receiving environment. The objective of this study is to optimize the treatment of wastewater by coagulation-flocculation using aluminum sulphate as a coagulant. Various reaction parameters are taken into account, such as the coagulant dose, the pH of the solutions, the conductivity, the BOD5, the nitrates, the ammonium and the phosphates. We found from the different results obtained the optimal dose of aluminum sulphate is 400 mg/l with a reduction of 96.31%, 82.44% 90.95% and 78.74% respectively for phosphates, nitrates, ammonium and BOD5. It is recognized that pH influences the abatement rates of pollution contained in wastewater. For each water, there is a pH range for which coagulation- flocculation takes place rapidly. For our study, the optimum pH for removal of BOD5 and ammonium is between 6 and 7.

  19. Unexpected Ge-Ge contacts in the two-dimensional Ge{sub 4}Se{sub 3}Te phase and analysis of their chemical cause with the density of energy (DOE) function

    Energy Technology Data Exchange (ETDEWEB)

    Kuepers, Michael; Konze, Philipp M.; Maintz, Stefan; Steinberg, Simon [Institute of Inorganic Chemistry, Chair of Solid-State and Quantum Chemistry, RWTH Aachen University (Germany); Mio, Antonio M.; Cojocaru-Miredin, Oana; Zhu, Min; Wuttig, Matthias [I. Physikalisches Institut, RWTH Aachen University (Germany); Mueller, Merlin; Mayer, Joachim [Gemeinschaftslabor fuer Elektronenmikroskopie, RWTH Aachen University (Germany); Luysberg, Martina [Ernst-Ruska-Center, Forschungszentrum Juelich GmbH (Germany); Dronskowski, Richard [Institute of Inorganic Chemistry, Chair of Solid-State and Quantum Chemistry, RWTH Aachen University (Germany); Juelich-Aachen Research Alliance (JARA-HPC), RWTH Aachen University (Germany)

    2017-08-14

    A hexagonal phase in the ternary Ge-Se-Te system with an approximate composition of GeSe{sub 0.75}Te{sub 0.25} has been known since the 1960s but its structure has remained unknown. We have succeeded in growing single crystals by chemical transport as a prerequisite to solve and refine the Ge{sub 4}Se{sub 3}Te structure. It consists of layers that are held together by van der Waals type weak chalcogenide-chalcogenide interactions but also display unexpected Ge-Ge contacts, as confirmed by electron microscopy analysis. The nature of the electronic structure of Ge{sub 4}Se{sub 3}Te was characterized by chemical bonding analysis, in particular by the newly introduced density of energy (DOE) function. The Ge-Ge bonding interactions serve to hold electrons that would otherwise go into antibonding Ge-Te contacts. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. Coagulation-flocculation studies of laboratory wastewater using different combinations

    International Nuclear Information System (INIS)

    Butt, M. T.; Khan, R. A.; Khokar, A.; Iqbal, K.

    2013-01-01

    This study was conducted on the wastewater of PCSIR Laboratories complex Lahore. Both single as well as blended form was used in order to achieve maximum results and to reduce the cost. These experiments were conducted in Hudson Jars of one liter capacity using the coagulation technique for the removal of total suspended solids (TSS) and turbidity. The pH range was 6-8 and 4-10 for treatment. Four coagulants were used such as FeCl 3 , AlCl 3 . Alum and FeSO 4 , to remove the turbidity in single and blended form. Results of single coagulant are FeCl 3 from 39.7 to 11.51 NTU; AlCl 3 from 47.48 to 11.8 NTU. Alum 43 to 25.3NTU.FeSO 4 showed increasing trend in turbidity 53 to 120 NTU. The blended set of coagulants AlCl 3 +Alum turbidity from 45 to 18.55 NTU. The AlCl 3 and FeCl 3 showed almost similar results but after overnight settling results were excellent and alum showed also good results. The turbidity was removed from 54 to 27 NTU, 48 to 22 NTU, 44 to 17 NTU, and after overnight settling 33 to 4 NTU. The results of blended coagulants FeCl 3 +AlCl 3 after one, two and three hours settling were also studied and found best and blend AlCl3+Alum showed also similar trend and the blend of Alum+FeCl 3 after overnight settling was excellent. The same coagulants and its blended form were used for TSS removal and results are 278 to 7 mg/L, in blended form AlCl 3 +Alum show similar results but Alum + FeCl 3 showed excellent results. The TSS and turbidity removal was 87%, 97.5%. (author)

  1. The mechanism and properties of acid-coagulated milk gels

    Directory of Open Access Journals (Sweden)

    Chanokphat Phadungath

    2005-03-01

    Full Text Available Acid-coagulated milk products such as fresh acid-coagulated cheese varieties and yogurt areimportant dairy food products. However, little is known regarding the mechanisms involved in gel formation, physical properties of acid gels, and the effects of processing variables such as heat treatment and gelation temperature on the important physical properties of acid milk gels. This paper reviews the modern concepts of possible mechanisms involved in the formation of particle milk gel aggregation, along with recent developments including the use of techniques such as dynamic low amplitude oscillatory rheology to observe the gel formation process, and confocal laser scanning microscopy to monitor gel microstructure.

  2. Reincarnation of ancient links between coagulation and complement.

    Science.gov (United States)

    Conway, E M

    2015-06-01

    Throughout evolution, organisms have developed means to contain wounds by simultaneously limiting bleeding and eliminating pathogens and damaged host cells via the recruitment of innate defense mechanisms. Disease emerges when there is unchecked activation of innate immune and/or coagulation responses. A key component of innate immunity is the complement system. Concurrent excess activation of coagulation and complement - two major blood-borne proteolytic pathways - is evident in numerous diseases, including atherosclerosis, diabetes, venous thromboembolic disease, thrombotic microangiopathies, arthritis, cancer, and infectious diseases. Delineating the cross-talk between these two cascades will uncover novel therapeutic insights. © 2015 International Society on Thrombosis and Haemostasis.

  3. Apparent contact angle and contact angle hysteresis on liquid infused surfaces.

    Science.gov (United States)

    Semprebon, Ciro; McHale, Glen; Kusumaatmaja, Halim

    2016-12-21

    We theoretically investigate the apparent contact angle and contact angle hysteresis of a droplet placed on a liquid infused surface. We show that the apparent contact angle is not uniquely defined by material parameters, but also has a dependence on the relative size between the droplet and its surrounding wetting ridge formed by the infusing liquid. We derive a closed form expression for the contact angle in the limit of vanishing wetting ridge, and compute the correction for small but finite ridge, which corresponds to an effective line tension term. We also predict contact angle hysteresis on liquid infused surfaces generated by the pinning of the contact lines by the surface corrugations. Our analytical expressions for both the apparent contact angle and contact angle hysteresis can be interpreted as 'weighted sums' between the contact angles of the infusing liquid relative to the droplet and surrounding gas phases, where the weighting coefficients are given by ratios of the fluid surface tensions.

  4. The Coagulant Type Influence on Removal Efficiency of 5- and 6-Ring Pahs During Water Coagulation Process

    Directory of Open Access Journals (Sweden)

    Nowacka Anna

    2014-12-01

    Full Text Available The article presents results on investigation of the removal efficiency of selected 5- and 6-ring polycyclic aromatic hydrocarbons (benzo[a]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[j]fluoranthene, benzo[g,h,i]perylene, indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene from water during coagulation and sedimentation process. Two pre-hydrolyzed aluminum coagulants: PAX XL 19H and FLOKOR 105V were chosen for research. Process was carried out at optimum process parameters: rapid-mixing - 3 min at the rotational speed of 200 rpm, slow mixing - 10 min at 30 rpm, sedimentation - 60 min. The removal effectiveness was dependant on coagulant type and its composition. Better results in the removal of 5-and 6-ring PAHs were obtained after application of FLOKOR 105V (lower aluminum content than after using PAX XL 19H.

  5. Contact symmetries and Hamiltonian thermodynamics

    International Nuclear Information System (INIS)

    Bravetti, A.; Lopez-Monsalvo, C.S.; Nettel, F.

    2015-01-01

    It has been shown that contact geometry is the proper framework underlying classical thermodynamics and that thermodynamic fluctuations are captured by an additional metric structure related to Fisher’s Information Matrix. In this work we analyse several unaddressed aspects about the application of contact and metric geometry to thermodynamics. We consider here the Thermodynamic Phase Space and start by investigating the role of gauge transformations and Legendre symmetries for metric contact manifolds and their significance in thermodynamics. Then we present a novel mathematical characterization of first order phase transitions as equilibrium processes on the Thermodynamic Phase Space for which the Legendre symmetry is broken. Moreover, we use contact Hamiltonian dynamics to represent thermodynamic processes in a way that resembles the classical Hamiltonian formulation of conservative mechanics and we show that the relevant Hamiltonian coincides with the irreversible entropy production along thermodynamic processes. Therefore, we use such property to give a geometric definition of thermodynamically admissible fluctuations according to the Second Law of thermodynamics. Finally, we show that the length of a curve describing a thermodynamic process measures its entropy production

  6. Treatment of sugar beet thick juice spent wash by chemical and natural coagulants

    Directory of Open Access Journals (Sweden)

    Antov Mirjana G.

    2009-01-01

    Full Text Available The possibility of treatment of wastewater from bioethanol production by aluminium sulfate and natural coagulant extracted from common bean seed was studied. The highest coagulation activity at pH 6.5 is reached with analum dose of 1 g/l, but only a little lower coagulation activities were obtained by the dose of 0.05 and 0.10 g/l, which is more favorable for economic and environmental reasons. When natural coagulant from common bean was applied the highest coagulation activity, 14.3%, at pH 6.5 is reached with a dose of 0.5 ml/l. However, when common bean natural coagulant was used simultaneously with alum, the highest turbidity removal resulting in 24% coagulation activity was achieved and this was more efficient than when alum or natural coagulant were used.

  7. Early markers of blood coagulation and fibrinolysis activation in Argentine hemorrhagic fever

    NARCIS (Netherlands)

    Heller, M. V.; Marta, R. F.; Sturk, A.; Maiztegui, J. I.; Hack, C. E.; Cate, J. W.; Molinas, F. C.

    1995-01-01

    Junin virus, an arenaviridae, is the etiological agent of Argentine hemorrhagic fever. In addition to thrombocytopenia, patients present several alterations in both the blood coagulation and the fibrinolytic system, but diffuse intravascular coagulation could not be demonstrated. To investigate

  8. Networks of enzymatically oxidized membrane lipids support calcium-dependent coagulation factor binding to maintain hemostasis

    NARCIS (Netherlands)

    Lauder, S.N.; Allen-Redpath, K.; Slatter, D.A.; Aldrovandi, M.; O'Connor, A.; Farewell, D.; Percy, C.L.; Molhoek, J.E.; Rannikko, S.; Tyrrell, V.J.; Ferla, S.; Milne, G.L.; Poole, A.W.; Thomas, C.P.; Obaji, S.; Taylor, P.R.; Jones, S.A.; Groot, P.G. de; Urbanus, R.T.; Horkko, S.; Uderhardt, S.; Ackermann, J.; Jenkins, P.V.; Brancale, A.; Kronke, G.; Collins, P.W.; O'Donnell, V.B.

    2017-01-01

    Blood coagulation functions as part of the innate immune system by preventing bacterial invasion, and it is critical to stopping blood loss (hemostasis). Coagulation involves the external membrane surface of activated platelets and leukocytes. Using lipidomic, genetic, biochemical, and mathematical

  9. Therapeutic intervention in disseminated intravascular coagulation: have we made any progress in the last millennium?

    NARCIS (Netherlands)

    Levi, Marcel; de Jonge, Evert; van der Poll, Tom

    2002-01-01

    Disseminated intravascular coagulation (DIC) is a syndrome characterized by systemic intravascular activation of coagulation, leading to widespread deposition of fibrin in the circulation. Recent knowledge on important pathogenetic mechanisms that may lead to DIC has resulted in novel preventive and

  10. Effect of solvent evaporation and coagulation on morphology development of asymmetric membranes

    Science.gov (United States)

    Chandrasekaran, Neelakandan; Kyu, Thein

    2008-03-01

    Miscibility behavior of blends of amorphous polyamide (PA) and polyvinylpyrrolidone (PVP) was studied in relation to membrane formation. Dimethylsulfoxide (DMSO) and water were used as solvent and non-solvent, respectively. Differential scanning calorimetry and cloud point measurements revealed that the binary PA/PVP blends as well as the ternary PA/PVP/DMSO system were completely miscible at all compositions. However, the addition of non-solvent (water) to this ternary system has led to phase separation. Visual turbidity study was used to establish a ternary liquid-liquid phase diagram of the PA-PVP/DMSO/water system. Scanning Electron Microscopy (SEM) showed the development of finger-like and sponge-like cross sectional morphologies during coagulation. Effects of polymer concentration, PA/PVP blend ratio, solvent/non-solvent quality, and evaporation time on the resulting membrane morphology will be discussed.

  11. Improvement of extraction method of coagulation active components from Moringa oleifera seed

    OpenAIRE

    Okuda, Tetsuji; Baes, Aloysius U.; Nishijima, Wataru; Okada, Mitsumasa

    1999-01-01

    A new method for the extraction of the active coagulation component from Moringa oleifera seeds was developed and compared with the ordinary water extraction method (MOC–DW). In the new method, 1.0 mol l-1 solution of sodium chloride (MOC–SC) and other salts were used for extraction of the active coagulation component. Batch coagulation experiments were conducted using 500 ml of low turbid water (50 NTU). Coagulation efficiencies were evaluated based on the dosage required to remove kaolinite...

  12. Contact Dermatitis in Pediatrics.

    Science.gov (United States)

    Pelletier, Janice L; Perez, Caroline; Jacob, Sharon E

    2016-08-01

    Contact dermatitis is an umbrella term that describes the skin's reaction to contacted noxious or allergenic substances. The two main categories of contact dermatitis are irritant type and allergic type. This review discusses the signs, symptoms, causes, and complications of contact dermatitis. It addresses the testing, treatment, and prevention of contact dermatitis. Proper management of contact dermatitis includes avoidance measures for susceptible children. Implementation of a nickel directive (regulating the use of nickel in jewelry and other products that come into contact with the skin) could further reduce exposure to the most common allergens in the pediatric population. [Pediatr Ann. 2016;45(8):e287-e292.]. Copyright 2016, SLACK Incorporated.

  13. On the Method of Efficient Ice Cold Energy Storage Using a Heat Transfer of Direct Contact Phase Change and a Natural Circulation of a Working Medium in an Enclosure

    Science.gov (United States)

    Utaka, Yoshio; Saito, Akio; Nakata, Naoki

    The objectives of this report are to propose a new method of the high performance cold energy storage using ice as a phase change material and to clarify the heat transfer characteristics of the apparatus of ice cold energy storage based on the proposed principle. A working medium vapor layer a water layer and a working medium liquid layer stratified in this order from the top were kept in an enclosure composed of a condenser, an evaporator and a condensate receiver-and-return tube. The direct contact heat transfers between water or ice and a working medium in an enclosure were applied for realizing the high performance cold energy storage and release. In the storage and release processes, water changes the phase between the liquid and the solid, and the working medium cnanges between the vapor and the liquid with a natural circulation. Experimental apparatus was manufactured and R12 and R114 were selected as working media in the thermal energy storage enclosure. It was confirmed by the measurements that the efficient formation and melting of ice were achieved. Then, th e heat transfer characteristics were clarified for the effects of the initial water height, the initial height of woking medium liquid layer and the inlet coolant temperature.

  14. Characterization of coagulation factor synthesis in nine human primary cell types

    NARCIS (Netherlands)

    Dashty, Monireh; Akbarkhanzadeh, Vishtaseb; Zeebregts, Clark J.; Spek, C. Arnold; Sijbrands, Eric J.; Peppelenbosch, Maikel P.; Rezaee, Farhad

    2012-01-01

    The coagulation/fibrinolysis system is essential for wound healing after vascular injury. According to the standard paradigm, the synthesis of most coagulation factors is restricted to liver, platelets and endothelium. We challenged this interpretation by measuring coagulation factors in nine human

  15. Demonstration of the Coagulation and Diffusion of Homemade Slime Prepared under Acidic Conditions without Borate

    Science.gov (United States)

    Isokawa, Naho; Fueda, Kazuki; Miyagawa, Korin; Kanno, Kenichi

    2015-01-01

    Poly(vinyl alcohol) (PVA) precipitates in many kinds of aqueous salt solutions. While sodium sulfate, a coagulant for PVA fiber, precipitates PVA to yield a white rigid gel, coagulation of PVA with aluminum sulfate, a coagulant for water treatment, yields a slime-like viscoelastic fluid. One type of homemade slime is prepared under basic…

  16. Coagulation profile of children with sickle cell anemia in steady state ...

    African Journals Online (AJOL)

    Background: Sickle cell anemia is associated with a hypercoagulable state that may lead to alterations in a coagulation profile. Measurements of coagulation factors are known to have some predictive value for clinical outcome. Objectives: To determine the coagulation profile of children with SCA in steady state and crisis ...

  17. Comparison of coagulation activity tests in vitro for selected biomaterials

    NARCIS (Netherlands)

    van Oeveren, W; Haan, J; Lagerman, P; Schoen, T

    Testing of coagulation induced by external communicating medical devices is an International Standardisation Organization (ISO) requirement for products exposed to human blood. Four categories of tests are indicated by ISO 10993/4: a clotting test (partial thromboplastin time; PTT), thrombin

  18. Bladder perforation owing to a unipolar coagulating device.

    Science.gov (United States)

    Pakter, J; Budnick, L D

    1981-09-15

    A report on a patient who sustained a burn and perforation of the urinary bladder from visible sparks emanating from a unipolar coagulating device during the couse of laparoscopic sterilization is presented. It is the first report of urinary bladder burns using a unipolar coagulating device. A 24-year-old woman, gravida 10, para 3, abortus 7, underwent a laparoscopic sterilization with a unipolar coagulating device. As the physician was finishing the coagulation, a spark from the device caused a 1-2 cm burn with a central area of perforation into the urinary bladder. Conservative treatment was recommended, and consisted of Foley catheterization and drainage for 5 days. Initial urine culture revealed Klebsiella species, and oral ampicillin was prescribed. Hematuria was noted throughout the patient's hospitalization, and blood clots were present in the urine on Day 2 postoperation. The patient had no abdominal or flank pain, was afebrile, and had a stable hemoglobin level during the hospital stay. Cystography was performed on Day 5 postoperatively and demonstrated no perforation. Foley catheter was removed. Patient was discharged 2 days later and remains in good health 3 months postoperatively.

  19. Treatment of melanoidin wastewater by anaerobic digestion and coagulation.

    Science.gov (United States)

    Arimi, Milton M; Zhang, Yongjun; Götz, Gesine; Geißen, Sven-Uwe

    2015-01-01

    Melanoidins are dark-coloured recalcitrant pollutants found in many industrial wastewaters including coffee-manufacturing effluent, molasses distillery wastewater (MDWW) and other wastewater with molasses as the raw material. The wastewaters are mostly treated with anaerobic digestion after some dilution to minimize the inhibition effect. However, the dark colour and recalcitrant dissolved organic carbon (DOC) mainly caused by melanoidin are not effectively removed. The aim of this study was to investigate the removal of colour and remnant DOC by different coagulants from anaerobically digested MDWW. From the six coagulants tested, ferric chloride had the highest melanoidin (48%), colour (92.7%) and DOC (63.3%) removal at pH 5 and a dosage of 1.6 g/l. Both polymer and inorganic salt coagulants tested had optimal colour, melanoidin and DOC removal at acidic pH. The molecular size distribution of synthetic melanoidins by liquid chromatography-organic carbon detection indicated a preferential removal of high-molecular-weight melanoidins over low weight melanoidins by the coagulation. Further studies should focus on how to improve biodegradability of the treated effluent for it to be reused as dilution water for anaerobic digestion.

  20. Effects of a polymeric organic coagulant for industrial mineral oil ...

    African Journals Online (AJOL)

    The removal of chemical oxidation demand (COD), soap oil and grease (SOG), total suspended solids (TSS) and turbidity from the MOW were used as the response variables for the coagulation flotation process. This was done with a standard dissolved air flotation jar test. The results show that the actual COD, SOG, TSS ...

  1. The Inflammatory Actions of Coagulant and Fibrinolytic Proteases in Disease

    Directory of Open Access Journals (Sweden)

    Michael Schuliga

    2015-01-01

    Full Text Available Aside from their role in hemostasis, coagulant and fibrinolytic proteases are important mediators of inflammation in diseases such as asthma, atherosclerosis, rheumatoid arthritis, and cancer. The blood circulating zymogens of these proteases enter damaged tissue as a consequence of vascular leak or rupture to become activated and contribute to extravascular coagulation or fibrinolysis. The coagulants, factor Xa (FXa, factor VIIa (FVIIa, tissue factor, and thrombin, also evoke cell-mediated actions on structural cells (e.g., fibroblasts and smooth muscle cells or inflammatory cells (e.g., macrophages via the proteolytic activation of protease-activated receptors (PARs. Plasmin, the principle enzymatic mediator of fibrinolysis, also forms toll-like receptor-4 (TLR-4 activating fibrin degradation products (FDPs and can release latent-matrix bound growth factors such as transforming growth factor-β (TGF-β. Furthermore, the proteases that convert plasminogen into plasmin (e.g., urokinase plasminogen activator evoke plasmin-independent proinflammatory actions involving coreceptor activation. Selectively targeting the receptor-mediated actions of hemostatic proteases is a strategy that may be used to treat inflammatory disease without the bleeding complications of conventional anticoagulant therapies. The mechanisms by which proteases of the coagulant and fibrinolytic systems contribute to extravascular inflammation in disease will be considered in this review.

  2. Reduction of Turbidity of Water Using Locally Available Natural Coagulants

    Science.gov (United States)

    Asrafuzzaman, Md.; Fakhruddin, A. N. M.; Hossain, Md. Alamgir

    2011-01-01

    Turbidity imparts a great problem in water treatment. Moringa oleifera, Cicer arietinum, and Dolichos lablab were used as locally available natural coagulants in this study to reduce turbidity of synthetic water. The tests were carried out, using artificial turbid water with conventional jar test apparatus. Optimum mixing intensity and duration were determined. After dosing water-soluble extracts of Moringa oleifera, Cicer arietinum, and Dolichos lablab reduced turbidity to 5.9, 3.9, and 11.1 nephelometric turbidity unit (NTU), respectively, from 100 NTU and 5, 3.3, and 9.5, NTU, respectively, after dosing and filtration. Natural coagulants worked better with high, turbid, water compare to medium, or low, turbid, water. Highest turbidity reduction efficiency (95.89%) was found with Cicer arietinum. About 89 to 96% total coliform reduction were also found with natural coagulant treatment of turbid water. Using locally available natural coagulants, suitable, easier, and environment friendly options for water treatment were observed. PMID:23724307

  3. Coagulation / flocculation process in the removal of trace metals ...

    African Journals Online (AJOL)

    Attempts were made in this study to examine the effectiveness of polymer addition to coagulation process during treatment of a beverage industrial wastewater to remove some of its trace metals content such as lead, cadmium, total iron, total chromium, nickel and zinc. Experiments were conducted using the standard Jar ...

  4. Valproic acid modulates platelet and coagulation function ex vivo

    DEFF Research Database (Denmark)

    Bambakidis, Ted; Dekker, Simone E; Halaweish, Ihab

    2017-01-01

    of coagulopathy, it remains unknown whether this is a direct effect of the drug, or the establishment of an overall prosurvival phenotype. We thus conducted an ex-vivo experiment to determine if VPA has an effect on coagulation and platelet function. Ten swine were subjected to traumatic brain injury (TBI...

  5. Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.

    Science.gov (United States)

    Chen, Liming; Chen, Yu

    2015-01-01

    Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.

  6. Evaluation of the effect of advanced coagulation process to optimize ...

    African Journals Online (AJOL)

    Evaluation of the effect of advanced coagulation process to optimize the removal of natural organic matter in water (Case study: drinking water of Mashhad's ... and in addition to giving taste, color and odor to the water, they can intervene in the oxidization and removal of heavy metals such as arsenic, iron and manganese.

  7. Cosmetic wastewater treatment by coagulation and advanced oxidation processes.

    Science.gov (United States)

    Naumczyk, Jeremi; Bogacki, Jan; Marcinowski, Piotr; Kowalik, Paweł

    2014-01-01

    In this study, the treatment process of three cosmetic wastewater types has been investigated. Coagulation allowed to achieve chemical oxygen demand (COD) removal of 74.6%, 37.7% and 74.0% for samples A (Al2(SO4)3), B (Brentafloc F3) and C (PAX 16), respectively. The Fenton process proved to be effective as well - COD removal was equal to 75.1%, 44.7% and 68.1%, respectively. Coagulation with FeCl3 and the subsequent photo-Fenton process resulted in the best values of final COD removal equal to 92.4%, 62.8% and 90.2%. In case of the Fenton process, after coagulation these values were equal to 74.9%, 50.1% and 84.8%, while in case of the H2O2/UV process, the obtained COD removal was 83.8%, 36.2% and 80.9%. High value of COD removal in the Fenton process carried out for A and C wastewater samples was caused by a significant contribution of the final neutralization/coagulation. Very small effect of the oxidation reaction in the Fenton process in case of sample A resulting from the presence of antioxidants, 'OH radical scavengers' in the wastewater.

  8. OPTIMIZATION OF FLOCCULATION PROCESS BY MICROBIAL COAGULANT IN RIVER WATER

    Directory of Open Access Journals (Sweden)

    Fatin Nabilah Murad

    2017-12-01

    Full Text Available The existing process of coagulation and flocculation are using chemicals that known as cationic coagulant such as alum, ferric sulfate, calcium oxide, and organic polymers.  Thus, this study concentrates on optimizing of flocculation process by microbial coagulant in river water. Turbidity and suspended solids are the main constraints of river water quality in Malaysia. Hence, a study is proposed to produce microbial coagulants isolated locally for river water treatment. The chosen microbe used as the bioflocculant producer is Aspergillus niger. The parameters to optimization in the flocculation process were pH, bioflocculant dosage and effluent concentration. The research was done in the jar test process and the process parameters for maximum turbidity removal was validated. The highest flocculating activity was obtained on day seven of cultivation in the supernatant. The optimum pH and bioflocculant dosage for an optimize sedimentation process were between 4-5 and 2-3 mL for 0.3 g/L of effluent concentration respectively. The model was validated by using a river water sample from Sg. Pusu and the result showed that the model was acceptable to evaluate the bioflocculation process.

  9. Application of Moringa peregrina seed extract as a natural coagulant ...

    African Journals Online (AJOL)

    Hamed.B

    aqueous effluents from various manufacturing processes such as petroleum and ... rubber, plastics, paper, oil refineries and phenol-producing industries. ... coagulation, phenolic contaminants can damage ... al., 2008), enzymatic treatments (Mao et al., 2006), .... important not only for process economy but also for lower.

  10. Coagulation changes following traumatic brain injury and shock

    DEFF Research Database (Denmark)

    Sillesen, Martin

    2014-01-01

    In these studies, we have shown that coagulation and innate immunity pathways respond to trauma within minutes. Furthermore, the appearance of dysfunction of platelets as well as activation of the endothelium is rapidly manifested. Interestingly, many of these changes were attenuated by treatment...

  11. Production and characterization of water treatment coagulant from ...

    African Journals Online (AJOL)

    Base on high cost in coagulant for treating both domestic and industrial water in the recent time. There is need to identify cheaper and efficient methods of removing contaminant as the demand for clean water increases. A study was carried out to investigate the use of locally sourced Kaolinite clay from Okefomo ...

  12. Coagulation and Adsorption Treatment of Printing Ink Wastewater

    Directory of Open Access Journals (Sweden)

    Maja Klančnik

    2015-03-01

    Full Text Available The intention of the study was to improve the efficiency of total organic carbon (TOC and colour removal from the wastewater samples polluted with flexographic printing ink following coagulation treatments with further adsorption onto activated carbons and ground orange peel. The treatment efficiencies were compared to those of further flocculation treatments and of coagulation and adsorption processes individually. Coagulation was a relatively effective single-treatment method, removing 99.7% of the colour and 86.9% of the organic substances (TOC from the printing ink wastewater samples. Further flocculation did not further eliminate organic pollutants, whereas subsequent adsorption with 7 g/l of granular activated carbon further reduced organic substances by 35.1%, and adsorption with 7 g/l of powdered activated carbon further reduced organic substances by 59.3%. Orange peel was an inappropriate adsorbent for wastewater samples with low amounts of pollution, such as water that had been treated by coagulation. However, in highly polluted printing ink wastewater samples, the adsorption treatment with ground orange peel achieved efficiencies comparable to those of the granular activated carbon treatments.

  13. Optimization of coagulation-flocculation process for colour removal ...

    African Journals Online (AJOL)

    Response surface methodology (RSM) using face-centered central composite design (FCCD) was used to optimize the four variables. Increase in the colour removal efficiency was higher in acidic solution pH. Accurate control of coagulant dosages gave optimum destabilization of charged particles and re-stabilization ...

  14. Multiple roles of the coagulation protease cascade during virus infection.

    Science.gov (United States)

    Antoniak, Silvio; Mackman, Nigel

    2014-04-24

    The coagulation cascade is activated during viral infections. This response may be part of the host defense system to limit spread of the pathogen. However, excessive activation of the coagulation cascade can be deleterious. In fact, inhibition of the tissue factor/factor VIIa complex reduced mortality in a monkey model of Ebola hemorrhagic fever. Other studies showed that incorporation of tissue factor into the envelope of herpes simplex virus increases infection of endothelial cells and mice. Furthermore, binding of factor X to adenovirus serotype 5 enhances infection of hepatocytes but also increases the activation of the innate immune response to the virus. Coagulation proteases activate protease-activated receptors (PARs). Interestingly, we and others found that PAR1 and PAR2 modulate the immune response to viral infection. For instance, PAR1 positively regulates TLR3-dependent expression of the antiviral protein interferon β, whereas PAR2 negatively regulates expression during coxsackievirus group B infection. These studies indicate that the coagulation cascade plays multiple roles during viral infections.

  15. The coagulation system in endocrine disorders: a narrative review

    NARCIS (Netherlands)

    Squizzato, A.; Gerdes, V. E. A.; Ageno, W.; Büller, H. R.

    2007-01-01

    Endocrine disorders can influence the haemostatic balance. Abnormal coagulation test results have been observed in patients with abnormal hormone levels. Also unprovoked bleeding or thrombotic events have been associated with endocrine disease. The aim of the present review is to summarise the

  16. Evaluation of Chitin as Natural Coagulant in Water Treatment

    Directory of Open Access Journals (Sweden)

    V. Saritha

    2012-04-01

    Full Text Available The use of synthetic coagulants is not regarded as suitable due to health and economic considerations. The present study was aimed to investigate the effects of alum as coagulant in conjunction with chitin as coagulant aid on the removal of turbidity, hardness and Escherichia coli from water. A conventional jar test apparatus was employed for the tests. The experiment was conducted at three different pH conditions of 6, 7 and 8. The dosages chosen were 0.5, 1, 1.5 and 2mg/l. The results showed that turbidity decrease provided also a primary Escherichia coli reduction. Hardness removal efficiency was observed to be 93% at pH 7 with 1mg/l concentration by alum whereas chitin was stable at all the pH ranges showing highest removal at 1 and 1.5mg/l with pH 7. At low concentration chitin showed marginally better performance on hardness. In conclusion, using natural coagulants results in considerable savings in chemicals and sludge handling cost may be achieved.

  17. The effects of continuous venovenous hemofiltration on coagulation activation

    NARCIS (Netherlands)

    Bouman, Catherine S. C.; de Pont, Anne-Cornélie J. M.; Meijers, Joost C. M.; Bakhtiari, Kamran; Roem, Dorina; Zeerleder, Sacha; Wolbink, Gertjan; Korevaar, Johanna C.; Levi, Marcel; de Jonge, Evert

    2006-01-01

    INTRODUCTION: The mechanism of coagulation activation during continuous venovenous hemofiltration (CVVH) has not yet been elucidated. Insight into the mechanism(s) of hemostatic activation within the extracorporeal circuit could result in a more rational approach to anticoagulation. The aim of the

  18. optimization of coagulation-flocculation process for colour removal

    African Journals Online (AJOL)

    user

    2DEPARTMENT OF CHEMICAL ENGINEERING, NNAMDI AZIKIWE UNIVERSITY, AWKA, ANAMBRA STATE. ... The ability of organic polymer rich coagulants for colour removal from acid dye was studied. ... Response surface methodology (RSM) using face-centered ...... successfully applied for modeling and optimizing the.

  19. Whole blood coagulation time, haematocrit, haemoglobin and total ...

    African Journals Online (AJOL)

    The study was carried out to determine the values of whole blood coagulation time (WBCT), haematocrit (HM), haemaglobin (HB) and total protein (TP) of one hundred and eighteen apparently healthy turkeys reared under an extensive management system in Zaria. The mean values for WBCT, HM, HB and TP were 1.12 ...

  20. Coagulation and fibrinolysis in hyperparathyroidism secondary to vitamin D deficiency

    NARCIS (Netherlands)

    Elbers, Laura P. B.; Wijnberge, Marije; Meijers, Joost C. M.; Poland, Dennis C. W.; Brandjes, Dees P. M.; Fliers, Eric; Gerdes, Victor E. A.

    2018-01-01

    Abnormal coagulation tests have been observed in patients with primary hyperparathyroidism (HPT) suggesting a prothrombotic effect of parathyroid hormone (PTH). Vitamin D deficiency (VIDD) is the most frequent cause of secondary HPT. Aim of our study was to investigate the influence of HPT secondary

  1. Aversion substance(s) of the rat coagulating glands

    Science.gov (United States)

    Gawienowski, Anthony M.; Berry, Iver J.; Kennelly, James J.

    1982-01-01

    The aversive substance(s) present in adult male urine were not found in castrate rat urine. Removal of the coagulating glands also resulted in a loss of the aversion compounds. The aversion substances were restored to the urine after androgen treatment of the castrate rats.

  2. Effect of cyanobacterial peptides and proteins on coagulation of kaolinite

    Czech Academy of Sciences Publication Activity Database

    Novotná, Kateřina; Barešová, Magdalena; Čermáková, Lenka; Načeradská, Jana; Pivokonský, Martin

    2016-01-01

    Roč. 6, č. 2 (2016), s. 83-89 ISSN 1805-0174 Institutional support: RVO:67985874 Keywords : cellular organic matter * coagulation * complex formation * Microcystis aeruginosa * water treatment Subject RIV: DA - Hydrology ; Limnology http://www.ejes.cz/index.php/ejes/article/view/271/123

  3. A detailed aerosol mixing state model for investigating interactions between mixing state, semivolatile partitioning, and coagulation

    Directory of Open Access Journals (Sweden)

    J. Lu

    2010-04-01

    Full Text Available A new method for describing externally mixed particles, the Detailed Aerosol Mixing State (DAMS representation, is presented in this study. This novel method classifies aerosols by both composition and size, using a user-specified mixing criterion to define boundaries between compositional populations. Interactions between aerosol mixing state, semivolatile partitioning, and coagulation are investigated with a Lagrangian box model that incorporates the DAMS approach. Model results predict that mixing state affects the amount and types of semivolatile organics that partition to available aerosol phases, causing external mixtures to produce a more size-varying composition than internal mixtures. Both coagulation and condensation contribute to the mixing of emitted particles, producing a collection of multiple compositionally distinct aerosol populations that exists somewhere between the extremes of a strictly external or internal mixture. The selection of mixing criteria has a significant impact on the size and type of individual populations that compose the modeled aerosol mixture. Computational demands for external mixture modeling are significant and can be controlled by limiting the number of aerosol populations used in the model.

  4. Contact mechanics: contact area and interfacial separation from small contact to full contact

    International Nuclear Information System (INIS)

    Yang, C; Persson, B N J

    2008-01-01

    We present a molecular dynamics study of the contact between a rigid solid with a randomly rough surface and an elastic block with a flat surface. The numerical calculations mainly focus on the contact area and the interfacial separation from small contact (low load) to full contact (high load). For a small load the contact area varies linearly with the load and the interfacial separation depends logarithmically on the load. For a high load the contact area approaches the nominal contact area (i.e. complete contact), and the interfacial separation approaches zero. The numerical results have been compared with analytical theory and experimental results. They are in good agreement with each other. The present findings may be very important for soft solids, e.g. rubber, or for very smooth surfaces, where complete contact can be reached at moderately high loads without plastic deformation of the solids

  5. Coagulation sensors based on magnetostrictive delay lines for biomedical and chemical engineering applications

    International Nuclear Information System (INIS)

    Maliaritsi, E.; Zoumpoulakis, L.; Simitzis, J.; Vassiliou, P.; Hristoforou, E.

    2006-01-01

    Coagulation sensors based on the magnetostrictive delay line technique are presented in this paper. They are based on magnetostrictive ribbons and are used for measuring the coagulation, curing or solidification time of different liquids. Experimental results indicate that the presented sensing elements can determine the blood coagulation with remarkable repeatability, thus allowing their use as blood coagulation sensors. Additionally, results indicate that they can also measure curing time of resins, solidification of fluids and coagulation of chemical substances, therefore allowing their implementation in chemical engineering applications

  6. Treatment of sugar beet thick juice spent wash by chemical and natural coagulants

    OpenAIRE

    Antov Mirjana G.; Klašnja Mile T.; Šćiban Marina B.

    2009-01-01

    The possibility of treatment of wastewater from bioethanol production by aluminium sulfate and natural coagulant extracted from common bean seed was studied. The highest coagulation activity at pH 6.5 is reached with analum dose of 1 g/l, but only a little lower coagulation activities were obtained by the dose of 0.05 and 0.10 g/l, which is more favorable for economic and environmental reasons. When natural coagulant from common bean was applied the highest coagulation activity, 14.3%, at pH ...

  7. Treatment of sugar beet extraction juice stillage by natural coagulants extracted from common bean

    Directory of Open Access Journals (Sweden)

    Prodanović Jelena M.

    2015-01-01

    Full Text Available Distillery wastewaters have a great pollution potential, and pollution caused by them is one of the most critical environmental issues. This study is concerned with the coagulation efficiency of a new, environmental friendly, natural coagulant extracted from common bean seeds in the primary treatment of distillery wastewater in the bioethanol production from sugar beet juice. Active coagulation components were extracted from ground seeds of common bean with 0.5 mol/L NaCl. The obtained raw extract was used as a coagulant. The coagulation efficiency was measured by jar test at different pH values of wastewater, and a decrease in organic matter content was determined. The experiments confirmed that natural coagulant from common bean could be successfully used for the treatment of extraction juice distillery wastewater. The highest coagulation efficiencies were achieved at the pH 5.2 with a coagulant dose of 30 mL/L, and at the pH 8.5 with a coagulant dose of 5 mL/L, and they were 64.71% and 68.75% respectively. These encouraging results indicate that natural coagulant from common bean seeds is a potential alternative to conventional chemical coagulant/flocculant agents for treatment of wastewaters.[Projekat Ministarstva nauke Republike Srbije, br. III 43005

  8. Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking.

    Science.gov (United States)

    Wang, Guangye; Huang, Wenjun; Song, Qi; Liang, Jinfeng

    2017-11-01

    This study aims to analyze the contact areas and pressure distributions between the femoral head and mortar during normal walking using a three-dimensional finite element model (3D-FEM). Computed tomography (CT) scanning technology and a computer image processing system were used to establish the 3D-FEM. The acetabular mortar model was used to simulate the pressures during 32 consecutive normal walking phases and the contact areas at different phases were calculated. The distribution of the pressure peak values during the 32 consecutive normal walking phases was bimodal, which reached the peak (4.2 Mpa) at the initial phase where the contact area was significantly higher than that at the stepping phase. The sites that always kept contact were concentrated on the acetabular top and leaned inwards, while the anterior and posterior acetabular horns had no pressure concentration. The pressure distributions of acetabular cartilage at different phases were significantly different, the zone of increased pressure at the support phase distributed at the acetabular top area, while that at the stepping phase distributed in the inside of acetabular cartilage. The zones of increased contact pressure and the distributions of acetabular contact areas had important significance towards clinical researches, and could indicate the inductive factors of acetabular osteoarthritis. Copyright © 2016. Published by Elsevier Taiwan.

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Cleveland. "This is far from the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over-the-Counter Costume Contact Lenses Can ... was in severe pain and on medication for four weeks, and couldn't see well enough to ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados ... truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non- ...

  14. Colored Contact Lens Dangers

    Science.gov (United States)

    ... Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados ... truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non- ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Cleveland. "This is far from the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager ... the lenses. Never share contact lenses with another person. Get follow up exams with your eye care ...

  16. Contact Angle Goniometer

    Data.gov (United States)

    Federal Laboratory Consortium — Description:The FTA32 goniometer provides video-based contact angle and surface tension measurement. Contact angles are measured by fitting a mathematical expression...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to ... wear costume contact lenses for Halloween or any time of year, follow these guidelines: Get an eye ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... glow-in-the-dark lizard lenses, costume contacts can certainly add a spooky, eye-popping touch. But ... consideration as a standard contact lens because they can be purchased over-the-counter or on the ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering ... Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  1. Dermatitis, contact (image)

    Science.gov (United States)

    This picture shows a skin inflammation (dermatitis) caused by contact with a material that causes an allergic reaction in this person. Contact dermatitis is a relatively common condition, and can be caused ...

  2. Contact materials for nanoelectronics

    KAUST Repository

    Alshareef, Husam N.; Quevedo-Ló pez, Manuel Angel Quevedo; Majhi, Prashant

    2011-01-01

    In this article, we review current research activities in contact material development for electronic and nanoelectronic devices. A fundamental issue in contact materials research is to understand and control interfacial reactions and phenomena

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... the United States. All contact lenses are medical devices that require a prescription and proper fitting by an eye-care professional. Retailers that sell contacts without a ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  5. A thermodynamic model of contact angle hysteresis.

    Science.gov (United States)

    Makkonen, Lasse

    2017-08-14

    When a three-phase contact line moves along a solid surface, the contact angle no longer corresponds to the static equilibrium angle but is larger when the liquid is advancing and smaller when the liquid is receding. The difference between the advancing and receding contact angles, i.e., the contact angle hysteresis, is of paramount importance in wetting and capillarity. For example, it determines the magnitude of the external force that is required to make a drop slide on a solid surface. Until now, fundamental origin of the contact angle hysteresis has been controversial. Here, this origin is revealed and a quantitative theory is derived. The theory is corroborated by the available experimental data for a large number of solid-liquid combinations. The theory is applied in modelling the contact angle hysteresis on a textured surface, and these results are also in quantitative agreement with the experimental data.

  6. Ceramic Membrane combined with Powdered Activated Carbon (PAC) or Coagulation for Treatment of Impaired Quality Waters

    KAUST Repository

    Hamad, Juma Z.

    2013-08-29

    Ceramic membranes (CM) are robust membranes attributed with high production, long life span and stability against critical conditions. While capital costs are high, these are partially offset by lower operation and maintenance costs compared to polymeric membranes. Like any other low-pressure membrane (LPM), CM faces problems of fouling, low removal of organic matter and poor removal of trace organic compounds (TOrCs). Current pretreatment approaches that are mainly based on coagulation and adsorption can remove some organic matter but with a low removal of the biopolymers component which is responsible for fouling. Powdered activated carbon (PAC) accompanied with a LPM maintains good removal of TOrCs. However, enhanced removal of TOrCs to higher level is required. Submicron powdered activated carbon (SPAC), obtained after crushing commercial activated carbon into very fine particle, and novel activated carbon (KCU 6) which is characterized with larger pores and high surface area were employed. A pre-coating approach, which provides intimated contact between PAC and contaminants, was adopted for wastewater and (high DOC) surface water treatment. For seawater, in-line coagulation with iron III chloride was adopted. Both SPAC and KCU 6 showed good removal of biopolymers at a dose of 30 mg/L with > 85 % and 90 %, respectively. A dose of 40 mg/L of SPAC and 30 mg/L KCU 6 pre-coats were successful used in controlling membrane fouling. SPAC is suggested to remove biopolymers by physical means and adsorption while KCU 6 removed biopolymers through adsorption. Both KCU 6 and SPAC attained high removal of TOrCs whereas KCU 6 showed outstanding performance. Out of 29 TOrCs investigated, KCU 6 showed > 87 % TOrCs rejection for 28 compounds. In seawater pretreatment, transparent exopolymer particles (TEP) were found to be an important foulant. TEP promoted both reversible and irreversible fouling. TEP are highly electronegative while alumina CM is positively charged which

  7. Contact Lens Risks

    Science.gov (United States)

    ... There is a risk of eye infection from bacteria in swimming pool water, hot tubs, lakes and the ocean Replace your contact lens storage case every 3 months or as directed by your eye care professional. Other Risks of Contact Lenses Other risks of contact lenses include pink eye ( ...

  8. Hydrogenation of passivated contacts

    Energy Technology Data Exchange (ETDEWEB)

    Nemeth, William; Yuan, Hao-Chih; LaSalvia, Vincenzo; Stradins, Pauls; Page, Matthew R.

    2018-03-06

    Methods of hydrogenation of passivated contacts using materials having hydrogen impurities are provided. An example method includes applying, to a passivated contact, a layer of a material, the material containing hydrogen impurities. The method further includes subsequently annealing the material and subsequently removing the material from the passivated contact.

  9. Mixed Lubricated Line Contacts

    NARCIS (Netherlands)

    Faraon, I.C.

    2005-01-01

    The present work deals with friction in mixed lubricated line contacts. Components in systems are becoming smaller and due to, for instance power transmitted, partial contact may occur. In industrial applications, friction between the moving contacting surfaces cannot be avoided, therefore it is

  10. New Cosmetic Contact Allergens

    Directory of Open Access Journals (Sweden)

    An Goossens

    2015-02-01

    Full Text Available Allergic and photo-allergic contact dermatitis, and immunologic contact urticaria are potential immune-mediated adverse effects from cosmetics. Fragrance components and preservatives are certainly the most frequently observed allergens; however, all ingredients must be considered when investigating for contact allergy.

  11. MILK COAGULATION PROPERTIES OF CATTLE BREEDS REARED IN ALPINE AREA

    Directory of Open Access Journals (Sweden)

    Giulio Visentin

    2015-09-01

    Full Text Available The aim of the present study was to apply mid-infrared spectroscopy prediction models developed for milk coagulation properties (MCP to a spectral dataset of 123,240 records collected over a 2-year period in the Alpine area, and to investigate sources of variation of the predicted MCP. Mixed linear models included fixed effects of breed, month and year of sampling, days in milk, parity, and the interactions between the main effects. Random effects were herd nested within breed, cow nested within breed, and the residual. All fixed effects were significant (P<0.05 in explaining the variation of MCP. In particular, milk clotting characteristics varied significantly among breeds, and local Alpine Grey breed exhibited the most favourable processing characteristics. Milk coagulation properties varied across lactation and were at their worst after the peak.

  12. Change of particle size distribution during Brownian coagulation

    International Nuclear Information System (INIS)

    Lee, K.W.

    1984-01-01

    Change in particle size distribution due to Brownian coagulation in the continuum regime has been stuied analytically. A simple analytic solution for the size distribution of an initially lognormal distribution is obtained based on the assumption that the size distribution during the coagulation process attains or can, at least, be represented by a time dependent lognormal function. The results are found to be in a form that corrects Smoluchowski's solution for both polydispersity and size-dependent kernel. It is further shown that regardless of whether the initial distribution is narrow or broad, the spread of the distribution is characterized by approaching a fixed value of the geometric standard deviation. This result has been compared with the self-preserving distribution obtained by similarity theory. (Author)

  13. Rheological behavior of raw natural rubber coagulated by microorganisms

    Directory of Open Access Journals (Sweden)

    Zhifen Wang

    2014-01-01

    Full Text Available Tests of the strain sweep, frequency sweep and stress relaxation for raw natural rubber coagulated by microorganisms (NR-m and raw natural rubber coagulated by acid (NR-a were carried out with the use of a rubber process analyzer (RPA. The results showed that the storage torque, complex viscosity of NR-m were higher than those of NR-a while the loss factor was lower. The effect of temperature on viscosity of raw NR was studied following the Arrhenious-Frenkel-Eyring model. The viscous flow behavior of NR-m was poorer than those of NR-a. Furthermore, stress relaxation measurements of raw NR showed a longer period of relaxation for NR-m.

  14. Impact of Rodenticides on the Coagulation Properties of Milk

    Directory of Open Access Journals (Sweden)

    Salam A. Ibrahim

    2018-04-01

    Full Text Available In this study, we investigated the impact of the rodenticides (strychnine, bromadiolone, and brodifacoum on milk pH, rennet coagulation time (RCT, and coagulum strength. Sub-lethal amounts of strychnine and bromadiolone produced an unnaturally large change in milk pH, compared to brodifacoum and brodifacoum on milk coagulation properties. All three studied rodenticides significantly affected RCT and coagulum strength. The presence of sub-lethal amounts of each individual rodenticide increased RCT by an overall mean of 17% (p < 0.001. Rodenticide contamination decreased coagulum strength by an overall mean of 26% (p < 0.05. Our results suggest that such changes could be noticeable at the farm, thus, potentially averting the mixture of contaminated milk with the tanker supply, and preventing downstream distribution to consumers.

  15. Weighted Flow Algorithms (WFA) for stochastic particle coagulation

    International Nuclear Information System (INIS)

    DeVille, R.E.L.; Riemer, N.; West, M.

    2011-01-01

    Stochastic particle-resolved methods are a useful way to compute the time evolution of the multi-dimensional size distribution of atmospheric aerosol particles. An effective approach to improve the efficiency of such models is the use of weighted computational particles. Here we introduce particle weighting functions that are power laws in particle size to the recently-developed particle-resolved model PartMC-MOSAIC and present the mathematical formalism of these Weighted Flow Algorithms (WFA) for particle coagulation and growth. We apply this to an urban plume scenario that simulates a particle population undergoing emission of different particle types, dilution, coagulation and aerosol chemistry along a Lagrangian trajectory. We quantify the performance of the Weighted Flow Algorithm for number and mass-based quantities of relevance for atmospheric sciences applications.

  16. Impact of Silver Nanoparticles on Haemolysis, Platelet Function and Coagulation

    Directory of Open Access Journals (Sweden)

    Julie Laloy

    2014-09-01

    Full Text Available Silver nanoparticles (Ag NPs are increasingly used in biomedical applications because of their large antimicrobial spectrum. Data in the literature on the ability of Ag NPs to perform their desired function without eliciting undesirable effects on blood elements are very limited and contradictory. We studied the impact of Ag NPs on erythrocyte integrity, platelet function and blood coagulation. Erythrocyte integrity was assessed by spectrophotometric measurement of haemoglobin release. Platelet adhesion and aggregation was determined by light transmission aggregometry and scanning electron microscopy. The calibrated thrombin generation test was used to study the impact on coagulation cascade. We demonstrated that Ag NPs induced haemolysis. They also increase platelet adhesion without having any impact on platelet aggregation. Finally, they also had procoagulant potential. Bringing all data from these tests together, the no observed effect concentration is 5 μg/mL.

  17. Weighted Flow Algorithms (WFA) for stochastic particle coagulation

    Science.gov (United States)

    DeVille, R. E. L.; Riemer, N.; West, M.

    2011-09-01

    Stochastic particle-resolved methods are a useful way to compute the time evolution of the multi-dimensional size distribution of atmospheric aerosol particles. An effective approach to improve the efficiency of such models is the use of weighted computational particles. Here we introduce particle weighting functions that are power laws in particle size to the recently-developed particle-resolved model PartMC-MOSAIC and present the mathematical formalism of these Weighted Flow Algorithms (WFA) for particle coagulation and growth. We apply this to an urban plume scenario that simulates a particle population undergoing emission of different particle types, dilution, coagulation and aerosol chemistry along a Lagrangian trajectory. We quantify the performance of the Weighted Flow Algorithm for number and mass-based quantities of relevance for atmospheric sciences applications.

  18. Evaluation of Disseminated Intravascular Coagulation in the Craniocerebral Traumas

    Directory of Open Access Journals (Sweden)

    Faruk Altinel

    2014-06-01

    Full Text Available Traumatic injury is one of the most important cause of disseminated intravascular coagulation (DIC. It occurs because of blood loss and hemodilution due to fluid resuscitation. The incidence of trauma associated DIC is mainly higher in the craniocerebral traumas. Even though craniocerebral trauma related DIC is well defined, the pathophysiology has been poorly characterized in the literature. Due to the fact that brain tissue is highly significant for procoagulant molecules, craniocerebral traumas are closely related to DIC. In the current study, 30 patients admitted to emergency room have been considered on the first and fifth day of admission to the hospital for the coagulation tests to evaluate DIC in both two groups. [Cukurova Med J 2014; 39(3.000: 488-495

  19. The changes in the fibrinogen concentration and coagulation pathways in winter and summer in cattle

    Directory of Open Access Journals (Sweden)

    ameneh khoshvaghti

    2013-08-01

    Full Text Available Fibrinogen is an important coagulation factor and a positive acute phase protein and its levels increases in cases of inflammation infection and stress. The present research was done to determine whether the fibrinogen concentration, prothrombin time (PT and activated partial thromboplastin time (APTT can be affected by seasonal changes. In this study, the blood of ten apparently healthy cows from around Yasouj city were taken under aseptic conditions and, then the plasma was separated. The fibrinogen concentration, was assayed by sedimentation refractometry method, PT and APTT were measurement by coagolometric method. The statistical analysis indicated that there was significant difference between the mean concentration of fibrinogen in summer and winter (P0.05. It is concluded that seasonal changes can affect the fibrinogen concentration but does no affect PT and APTT significantly.

  20. Comparison of different methods used in integral codes to model coagulation of aerosols

    Science.gov (United States)

    Beketov, A. I.; Sorokin, A. A.; Alipchenkov, V. M.; Mosunova, N. A.

    2013-09-01

    The methods for calculating coagulation of particles in the carrying phase that are used in the integral codes SOCRAT, ASTEC, and MELCOR, as well as the Hounslow and Jacobson methods used to model aerosol processes in the chemical industry and in atmospheric investigations are compared on test problems and against experimental results in terms of their effectiveness and accuracy. It is shown that all methods are characterized by a significant error in modeling the distribution function for micrometer particles if calculations are performed using rather "coarse" spectra of particle sizes, namely, when the ratio of the volumes of particles from neighboring fractions is equal to or greater than two. With reference to the problems considered, the Hounslow method and the method applied in the aerosol module used in the ASTEC code are the most efficient ones for carrying out calculations.

  1. Commonly Used Dietary Supplements on Coagulation Function during Surgery

    Directory of Open Access Journals (Sweden)

    Chong-Zhi Wang

    2015-07-01

    Full Text Available Background: Patients who undergo surgery appear to use dietary supplements significantly more frequently than the general population. Because they contain pharmacologically active compounds, dietary supplements may affect coagulation and platelet function during the perioperative period through direct effects, pharmacodynamic interactions, and pharmacokinetic interactions. However, in this regard, limited studies have been conducted that address the pharmacological interactions of dietary supplements. To avoid possible bleeding risks during surgery, information about the potential complications of dietary supplements during perioperative management is important for physicians. Methods: Through a systematic database search of all available years, articles were identified in this review if they included dietary supplements and coagulation/platelet function, while special attention was paid to studies published after 1990. Results: Safety concerns are reported in commercially available dietary supplements. Effects of the most commonly used natural products on blood coagulation and platelet function are systematically reviewed, including 11 herbal medicines (echinacea, ephedra, garlic, ginger, ginkgo, ginseng, green tea, kava, saw palmetto, St John’s wort, and valerian and four other dietary supplements (coenzyme Q10, glucosamine and chondroitin sulfate, fish oil, and vitamins. Bleeding risks of garlic, ginkgo, ginseng, green tea, saw palmetto, St John’s wort, and fish oil are reported. Cardiovascular instability was observed with ephedra, ginseng, and kava. Pharmacodynamic and pharmacokinetic interactions between dietary supplements and drugs used in the perioperative period are discussed. Conclusions: To prevent potential problems associated with the use of dietary supplements, physicians should be familiar with the perioperative effects of commonly used dietary supplements. Since the effects of dietary supplements on coagulation and platelet

  2. Commonly Used Dietary Supplements on Coagulation Function during Surgery

    Science.gov (United States)

    Wang, Chong-Zhi; Moss, Jonathan; Yuan, Chun-Su

    2015-01-01

    Abstract Background Patients who undergo surgery appear to use dietary supplements significantly more frequently than the general population. Because they contain pharmacologically active compounds, dietary supplements may affect coagulation and platelet function during the perioperative period through direct effects, pharmacodynamic interactions, and pharmacokinetic interactions. However, in this regard, limited studies have been conducted that address the pharmacological interactions of dietary supplements. To avoid possible bleeding risks during surgery, information about the potential complications of dietary supplements during perioperative management is important for physicians. Methods Through a systematic database search of all available years, articles were identified in this review if they included dietary supplements and coagulation/platelet function, while special attention was paid to studies published after 1990. Results Safety concerns are reported in commercially available dietary supplements. Effects of the most commonly used natural products on blood coagulation and platelet function are systematically reviewed, including 11 herbal medicines (echinacea, ephedra, garlic, ginger, ginkgo, ginseng, green tea, kava, saw palmetto, St John’s wort, and valerian) and four other dietary supplements (coenzyme Q10, glucosamine and chondroitin sulfate, fish oil, and vitamins). Bleeding risks of garlic, ginkgo, ginseng, green tea, saw palmetto, St John’s wort, and fish oil are reported. Cardiovascular instability was observed with ephedra, ginseng, and kava. Pharmacodynamic and pharmacokinetic interactions between dietary supplements and drugs used in the perioperative period are discussed. Conclusions To prevent potential problems associated with the use of dietary supplements, physicians should be familiar with the perioperative effects of commonly used dietary supplements. Since the effects of dietary supplements on coagulation and platelet function are

  3. Infrared coagulation versus rubber band ligation in early stage hemorrhoids.

    Science.gov (United States)

    Gupta, P J

    2003-10-01

    The ideal therapy for early stages of hemorrhoids is always debated. Some are more effective but are more painful, others are less painful but their efficacy is also lower. Thus, comfort or efficacy is a major concern. In the present randomized study, a comparison is made between infrared coagulation and rubber band ligation in terms of effectiveness and discomfort. One hundred patients with second degree bleeding piles were randomized prospectively to either rubber band ligation (N = 54) or infrared coagulation (N = 46). Parameters measured included postoperative discomfort and pain, time to return to work, relief in incidence of bleeding, and recurrence rate. The mean age was 38 years (range 19-68 years). The mean duration of disease was 17.5 months (range 12 to 34 months). The number of male patients was double that of females. Postoperative pain during the first week was more intense in the band ligation group (2-5 vs 0-3 on a visual analogue scale). Post-defecation pain was more intense with band ligation and so was rectal tenesmus (P = 0.0059). The patients in the infrared coagulation group resumed their duties earlier (2 vs 4 days, P = 0.03), but also had a higher recurrence or failure rate (P = 0.03). Thus, we conclude that band ligation, although more effective in controlling symptoms and obliterating hemorrhoids, is associated with more pain and discomfort to the patient. As infrared coagulation can be conveniently repeated in case of recurrence, it could be considered to be a suitable alternative office procedure for the treatment of early stage hemorrhoids.

  4. Infrared coagulation versus rubber band ligation in early stage hemorrhoids

    Directory of Open Access Journals (Sweden)

    P.J. Gupta

    2003-10-01

    Full Text Available The ideal therapy for early stages of hemorrhoids is always debated. Some are more effective but are more painful, others are less painful but their efficacy is also lower. Thus, comfort or efficacy is a major concern. In the present randomized study, a comparison is made between infrared coagulation and rubber band ligation in terms of effectiveness and discomfort. One hundred patients with second degree bleeding piles were randomized prospectively to either rubber band ligation (N = 54 or infrared coagulation (N = 46. Parameters measured included postoperative discomfort and pain, time to return to work, relief in incidence of bleeding, and recurrence rate. The mean age was 38 years (range 19-68 years. The mean duration of disease was 17.5 months (range 12 to 34 months. The number of male patients was double that of females. Postoperative pain during the first week was more intense in the band ligation group (2-5 vs 0-3 on a visual analogue scale. Post-defecation pain was more intense with band ligation and so was rectal tenesmus (P = 0.0059. The patients in the infrared coagulation group resumed their duties earlier (2 vs 4 days, P = 0.03, but also had a higher recurrence or failure rate (P = 0.03. Thus, we conclude that band ligation, although more effective in controlling symptoms and obliterating hemorrhoids, is associated with more pain and discomfort to the patient. As infrared coagulation can be conveniently repeated in case of recurrence, it could be considered to be a suitable alternative office procedure for the treatment of early stage hemorrhoids.

  5. Commonly Used Dietary Supplements on Coagulation Function during Surgery.

    Science.gov (United States)

    Wang, Chong-Zhi; Moss, Jonathan; Yuan, Chun-Su

    2015-09-01

    Patients who undergo surgery appear to use dietary supplements significantly more frequently than the general population. Because they contain pharmacologically active compounds, dietary supplements may affect coagulation and platelet function during the perioperative period through direct effects, pharmacodynamic interactions, and pharmacokinetic interactions. However, in this regard, limited studies have been conducted that address the pharmacological interactions of dietary supplements. To avoid possible bleeding risks during surgery, information of potential complications of dietary supplements during perioperative management is important for physicians. Through a systematic database search of all available years, articles were identified in this review if they included dietary supplements and coagulation/platelet function, while special attention was paid to studies published after 1990. Safety concerns are reported in commercially available dietary supplements. Effects of the most commonly used natural products on blood coagulation and platelet function are systematically reviewed, including 11 herbal medicines (echinacea, ephedra, garlic, ginger, ginkgo, ginseng, green tea, kava, saw palmetto, St John's wort, and valerian) and 4 other dietary supplements (coenzyme Q 10 , glucosamine and chondroitin sulfate, fish oil, and vitamins). Bleeding risks of garlic, ginkgo, ginseng, green tea, saw palmetto, St John's wort, and fish oil are reported. Cardiovascular instability was observed with ephedra, ginseng, and kava. Pharmacodynamic and pharmacokinetic interactions between dietary supplements and drugs used in the perioperative period are discussed. To prevent potential problems associated with the use of dietary supplements, physicians should be familiar with the perioperative effects of commonly used dietary supplements. Since the effects of dietary supplements on coagulation and platelet function are difficult to predict, it is prudent to advise their

  6. Chronic sleep deprivation markedly reduces coagulation factor VII expression

    Science.gov (United States)

    Pinotti, Mirko; Bertolucci, Cristiano; Frigato, Elena; Branchini, Alessio; Cavallari, Nicola; Baba, Kenkichi; Contreras-Alcantara, Susana; Ehlen, J. Christopher; Bernardi, Francesco; Paul, Ketema N.; Tosini, Gianluca

    2010-01-01

    Chronic sleep loss, a common feature of human life in industrialized countries, is associated to cardiovascular disorders. Variations in functional parameters of coagulation might contribute to explain this relationship. By exploiting the mouse model and a specifically designed protocol, we demonstrated that seven days of partial sleep deprivation significantly decreases (−30.5%) the thrombin generation potential in plasma evaluated upon extrinsic (TF/FVIIa pathway) but not intrinsic activation of coagulation. This variation was consistent with a decrease (−49.8%) in the plasma activity levels of factor VII (FVII), the crucial physiologicalal trigger of coagulation, which was even more pronounced at the liver mRNA level (−85.7%). The recovery in normal sleep conditions for three days completely restored thrombin generation and FVII activity in plasma. For the first time, we demonstrate that chronic sleep deprivation on its own reduces, in a reversible manner, the FVII expression levels, thus influencing the TF/FVIIa activation pathway efficiency. PMID:20418241

  7. Activation of the coagulation cascade in patients with scrub typhus.

    Science.gov (United States)

    Lee, Hee-Jeong; Park, Chi-Young; Park, Sang-Gon; Yoon, Na-Ra; Kim, Dong-Min; Chung, Choon-Hae

    2017-09-01

    This retrospective study aimed to evaluate the levels of coagulation factors and presence of disseminated intravascular coagulation (DIC) in patients with scrub typhus. We included patients confirmed to have scrub typhus at the Chosun University Hospital between September 2004 and December 2009. The DIC scores were evaluated in 365 patients and 36 healthy controls. The median concentrations of fibrinogen, d-dimer, and fibrin/fibrinogen degradation products (FDP) were compared between patients and healthy controls (pscrub typhus had longer prothrombin time and lower platelet counts than the controls. Major bleeding was observed in 18/365 patients with scrub typhus. Fifty-one (14.0%) patients presented with severe complications of scrub typhus. Overt DIC and thrombocytopenia (scrub typhus had overt DIC, as defined by the International Society on Thrombosis and Hemostasis DIC score (DIC1) and the DIC-scoring template with a fibrinogen/C-reactive protein-ratio (DIC2), respectively. Three (16.7%) and 10 (55.6%) patients with bleeding had overt DIC, as defined by the DIC1 and DIC2, respectively. Seven (13.7%) and 26 (51%) patients with severe illness had overt DIC, as defined by DIC1 and DIC2, respectively. In conclusion, activation of the coagulation system is an important feature of scrub typhus and is correlated with severe disease, including bleeding. This is the first study to report a relationship between DIC and scrub typhus. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Coagulation of dielectric dust grains due to variable asymmetric charging

    International Nuclear Information System (INIS)

    Manweiler, Jerry W.; Armstrong, Thomas P.; Cravens, Thomas E.

    1998-01-01

    Observational evidence of electrical forces acting significantly on small solids is present for both the modern solar system in Saturn's rings and the ancient solar system in chondritic meteorites. It is likely that grain-grain coagulation rates are affected by the distribution of charges on small grains. Plasma particle impacts and photoelectric effects can provide the charges. It appears that some charging is inevitable and that plasma grain interactions need to be evaluated to determine the size of the effect on coagulation rates. We apply the results of our previous charging work to models of the protoplanetary nebula. It is expected that the protoplanetary nebula is weakly ionized except in certain instances and locations such as: solar flares in the interior, ultraviolet radiation at the outer boundary, and during enhanced luminosity of the star. Since the grains we study are non-conducting and show strong dipole moments in flowing plasma, we modify the geometric cross sections to include the effects of flowing plasma on non-conducting grains with plasma mediated shielding. This paper provides results showing how plasma flow affects the processes involved in charging the grains--total charge and charge distribution. We calculate the modifications to the cross sections and subsequent changes in the coagulation rates

  9. Effect of Centrifuge Temperature on Routine Coagulation Tests.

    Science.gov (United States)

    Yazar, Hayrullah; Özdemir, Fatma; Köse, Elif

    2018-01-01

    This study investigated the effects of cooled and standard centrifuges on the results of coagulation tests to examine the effects of centrifugation temperature. Equal-volume blood samples from each patient were collected at the same time intervals and subjected to standard (25°C) and cooled centrifugation (2-4°C). Subsequently, the prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (aPTT), fibrinogen, and D-dimer values were determined in runs with the same lot numbers in the same coagulation device using the Dia-PT R (PT and INR), Dia-PTT-liquid (aPTT), Dia-FIB (fibrinogen), and Dia-D-dimer kits, respectively. The study enrolled 771 participants. The PT was significantly (p centrifuges were as follows: PT 10.30 versus 10.50 s; PT (INR) 1.04 versus 1.09 s; APTT 28.90 versus 29.40 s; fibrinogen 321.5 versus 322.1 mg/dL; and D-dimer 179.5 versus 168.7 µg FEU/mL. There were significant differences (p centrifuges. Centrifuge temperature can have a significant effect on the results of coagulation tests. However, broad and specific disease-based studies are needed. © 2018 S. Karger AG, Basel.

  10. Slaughterhouse wastewater treatment by combined chemical coagulation and electrocoagulation process.

    Science.gov (United States)

    Bazrafshan, Edris; Kord Mostafapour, Ferdos; Farzadkia, Mehdi; Ownagh, Kamal Aldin; Mahvi, Amir Hossein

    2012-01-01

    Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD(5) removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater.

  11. Slaughterhouse Wastewater Treatment by Combined Chemical Coagulation and Electrocoagulation Process

    Science.gov (United States)

    Bazrafshan, Edris; Kord Mostafapour, Ferdos; Farzadkia, Mehdi; Ownagh, Kamal Aldin; Mahvi, Amir Hossein

    2012-01-01

    Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD5 removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater. PMID:22768233

  12. Microwave coagulation therapy and drug injection to treat splenic injury.

    Science.gov (United States)

    Zhang, Guoming; Sun, Yuanyuan; Yu, Jie; Dong, Lei; Mu, Nannan; Liu, Xiaohong; Liu, Lanfen; Zhang, Yan; Wang, Xiaofei; Liang, Ping

    2014-01-01

    The present study compares the efficacy of 915- and 2450-MHz contrast-enhanced ultrasound (CEUS)-guided percutaneous microwave coagulation with that of CEUS-guided thrombin injection for the treatment of trauma-induced spleen hemorrhage. In a canine splenic artery hemorrhage model with two levels of arterial diameter (A, microwaves and drug injection. Therapy efficacy was measured by comparing bleeding rate, hemostatic time, bleeding index, bleeding volume, and pathology. The most efficient technique was CEUS-guided 915-MHz percutaneous microwave coagulation therapy in terms of action time and total blood loss. The success rate of the 915-MHz microwave group was higher than that of the 2450-MHz microwave and the drug injection groups (except A level, P microwave group than those in the 2450-MHz microwave and drug injection groups (P microwave group, but pathologic changes of light injury could be seen in the other groups. The present study provides evidence that microwave coagulation therapy is more efficient than thrombin injection for the treatment of splenic hemorrhage. Furthermore, treatment with 915-MHz microwaves stops bleeding more rapidly and generates a wider cauterization zone than does treatment with 2450-MHz microwaves. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Enhancement of sedimentation and coagulation with static magnetic field

    Science.gov (United States)

    Zieliński, Marcin; Dębowski, Marcin; Hajduk, Anna; Rusanowska, Paulina

    2017-11-01

    The static magnetic field can be an alternative method for wastewater treatment. It has been proved that this physical factor, accelerates the biochemical processes, catalyzes advanced oxidation, intensifies anaerobic and aerobic processes or reduces swelling of activated sludge. There are also reports proving the positive impact of the static magnetic field on the coagulation and sedimentation, as well as the conditioning and dewatering of sludge. In order to be applied in larger scale the published results should be verified and confirmed. In the studies, the enhancement of sedimentation by the static magnetic field was observed. The best sedimentation was noted in the experiment, where magnetizers were placed on activated sludge bioreactor and secondary settling tank. No effect of the static magnetic field on coagulation with the utilization of PIX 113 was observed. However, the static magnetic field enhanced coagulation with the utilization of PAX-XL9. The results suggest that increased sedimentation of colloids and activated sludge, can in practice mean a reduction in the size of the necessary equipment for sedimentation with an unchanged efficiency of the process.

  14. Numerical Simulation of the Coagulation Dynamics of Blood

    Directory of Open Access Journals (Sweden)

    T. Bodnár

    2008-01-01

    Full Text Available The process of platelet activation and blood coagulation is quite complex and not yet completely understood. Recently, a phenomenological meaningful model of blood coagulation and clot formation in flowing blood that extends existing models to integrate biochemical, physiological and rheological factors, has been developed. The aim of this paper is to present results from a computational study of a simplified version of this coupled fluid-biochemistry model. A generalized Newtonian model with shear-thinning viscosity has been adopted to describe the flow of blood. To simulate the biochemical changes and transport of various enzymes, proteins and platelets involved in the coagulation process, a set of coupled advection–diffusion–reaction equations is used. Three-dimensional numerical simulations are carried out for the whole model in a straight vessel with circular cross-section, using a finite volume semi-discretization in space, on structured grids, and a multistage scheme for time integration. Clot formation and growth are investigated in the vicinity of an injured region of the vessel wall. These are preliminary results aimed at showing the validation of the model and of the numerical code.

  15. Removal of arsenic from contaminated water using coagulation enhanced microfiltration

    International Nuclear Information System (INIS)

    Volchek, K.; Velicogna, D.; Dumouchel, A.; Wong, W.P.; Brown, C.E.

    2002-01-01

    Results of an innovative arsenic removal process were presented. The process is based on a combination of coagulation and microfiltration processes. Coagulation-Enhanced Microfiltration (CEMF) may eventually become a full-scale commercial technology. This study focused on the process with respect to groundwater treatment because of the importance of arsenic contamination in drinking water. Most experiments were bench-scale using tap water spiked with arsenic. Ferric chloride, which is commonly used in arsenic removal processes was also added. In addition, some tests were conducted on actual arsenic-contaminated water from the effluent treatment plant of a former mining site in Ontario. Results indicate a high arsenic removal efficiency in both spiked and actual water solutions. The microfiltration significantly reduced the level of arsenic in the treatment. This paper described the characteristics of membrane separation. It also presented information regarding chemically enhanced membrane filtration and coagulation-enhanced microfiltration. Bench-scale tests were conducted with both tubular membranes and with immersed capillary membranes. The effect of iron to arsenic ratios on the effectiveness of the system was also tested. It was recommended that future research should include a field study of the process on a pilot-scale to optimize process parameters and to accurately determine the cost of the process. 16 refs., 8 tabs., 9 figs

  16. OPTIMISATION OF HIBISCUS SABDARIFFA AS A NATURAL COAGULANT TO TREAT CONGO RED IN WASTEWATER

    Directory of Open Access Journals (Sweden)

    MUN Y. YONG

    2016-02-01

    Full Text Available The process of coagulation is commonly practiced in water and wastewater treatment to reduce level of dissolved chemical, turbidity and so on with the usage of coagulant. Aluminium sulphate (alum is the most commonly used coagulant, however, recent studies show that residual aluminium in drinking water and sludge may induce Alzheimer’s disease and environmental issues. Natural coagulant which is environmental friendly and non-toxic is developed as an alternative to overcome these issues. In this work, Hibiscus Sabdariffa was studied as natural coagulant to treat dye wastewater containing Congo red. The seeds were extracted with different solvent such as distilled water, 0.5 M NaCl and 0.05 M NaOH to extract the coagulation agent. The working parameters were optimised using Response Surface Methodology (RSM. 0.5 M NaCl was found to have highest colour removal of 95.1 % among the solvents. In addition, Hibiscus Sabdariffa seed was found to be an effective coagulant that has 91.2 % colour removal at the optimal working condition of pH 2, 190 mg/L coagulant dosage at 400 ppm of dye concentration. It was also been identified that the performance of natural coagulant is comparable with conventional coagulant, aluminium sulphate with colour removal of 91.2 % and 92.3 % respectively.

  17. The evaluation study of helical CT for hepatocellular carcinoma with microwave coagulation treatment

    International Nuclear Information System (INIS)

    Zheng Keguo; Xu Dasheng; Xie Xiaoyan; Peng Zhenpeng

    2002-01-01

    Objective: To study the helical CT signs of the hepatocellular carcinoma (HCC) after percutaneous microwave coagulation therapy (PMCT) and to evaluate the correlation between the helical CT signs and the therapeutic effect of HCC. Methods: The helical CT signs were analyzed in 22 cases with 26 lesions of the hepatocellular carcinoma that were treated with PMCT under ultrasonic guidance. Results: In 21 lesions, no enhancement was detected in the lesion border or inside the lesion at hepatic arterial phase (HAP) and portal venous phase (PVP). In 7 lesions, the slight or marked patchy enhancement was revealed in the surrounding liver of the lesions in HAP. In 5 lesions, nodular enhancement was found in the lesion border or inside the lesion in HAP. Conclusion: The dual-phase helical CT might be accurate in judging the therapeutic effect of HCC after PMCT. If no enhancement was showed in the lesions in the dual-phase helical CT, it indicated that no tumor survived. If slight or marked patchy pattern enhancement was revealed in the surrounding liver of the lesions in HAP, it was a normal reaction after PMCT. If nodular enhancement was found in the lesion border or inside the lesion in HAP, it indicated that the tumor partially survived

  18. CONTACT RESISTANCE MODELING

    Directory of Open Access Journals (Sweden)

    S. V. LOSKUTOV

    2018-05-01

    Full Text Available Purpose. To determine the contribution of the real contact spots distribution in the total conductivity of the conductors contact. Methodology. The electrical contact resistance research was carried out on models. The experimental part of this work was done on paper with a graphite layer with membranes (the first type and conductive liquids with discrete partitions (the second type. Findings. It is shown that the contact electrical resistance is mainly determined by the real area of metal contact. The experimental dependence of the electrical resistance of the second type model on the distance between the electrodes and the potential distribution along the sample surface for the first type model were obtained. The theoretical model based on the principle of electric field superposition was considered. The dependences obtained experimentally and calculated by using the theoretical model are in good agreement. Originality. The regularity of the electrical contact resistance formation on a large number of membranes was researched for the first time. A new model of discrete electrical contact based on the liquid as the conducting environment with nuclear membrane partitions was developed. The conclusions of the additivity of contact and bulk electrical resistance were done. Practical value. Based on these researches, a new experimental method of kinetic macroidentation that as a parameter of the metal surface layer deformation uses the real contact area was developed. This method allows to determine the value of average contact stresses, yield point, change of the stress on the depth of deformation depending on the surface treatment.

  19. Contact and symplectic topology

    CERN Document Server

    Colin, Vincent; Stipsicz, András

    2014-01-01

    Symplectic and contact geometry naturally emerged from the mathematical description of classical physics. The discovery of new rigidity phenomena and properties satisfied by these geometric structures launched a new research field worldwide. The intense activity of many European research groups in this field is reflected by the ESF Research Networking Programme "Contact And Symplectic Topology" (CAST). The lectures of the Summer School in Nantes (June 2011) and of the CAST Summer School in Budapest (July 2012) provide a nice panorama of many aspects of the present status of contact and symplectic topology. The notes of the minicourses offer a gentle introduction to topics which have developed in an amazing speed in the recent past. These topics include 3-dimensional and higher dimensional contact topology, Fukaya categories, asymptotically holomorphic methods in contact topology, bordered Floer homology, embedded contact homology, and flexibility results for Stein manifolds.

  20. Introduction to contact mechanics

    CERN Document Server

    Fischer-Cripps, Anthony C

    2000-01-01

    Contact mechanics deals with the elastic or plastic contact between two solid objects, and is thus intimately connected with such topics as fracture, hardness, and elasticity.This text, intended for advanced undergraduates, begins with an introduction to the mechanical properties of materials, general fracture mechanics, and fractures in brittle solids.This is followed by a detailed discussion of stresses and the nature of elastic and elastic-plastic contact.

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial ...

  2. Colors and contact dermatitis.

    Science.gov (United States)

    Bonamonte, Domenico; Foti, Caterina; Romita, Paolo; Vestita, Michelangelo; Angelini, Gianni

    2014-01-01

    The diagnosis of skin diseases relies on several clinical signs, among which color is of paramount importance. In this review, we consider certain clinical presentations of both eczematous and noneczematous contact dermatitis in which color plays a peculiar role orientating toward the right diagnosis. The conditions that will be discussed include specific clinical-morphologic subtypes of eczematous contact dermatitis, primary melanocytic, and nonmelanocytic contact hyperchromia, black dermographism, contact chemical leukoderma, and others. Based on the physical, chemical, and biologic factors underlying a healthy skin color, the various skin shades drawing a disease picture are thoroughly debated, stressing their etiopathogenic origins and histopathologic aspects.

  3. Self-production of tissue factor-coagulation factor VII complex by ovarian cancer cells

    OpenAIRE

    Yokota, N; Koizume, S; Miyagi, E; Hirahara, F; Nakamura, Y; Kikuchi, K; Ruf, W; Sakuma, Y; Tsuchiya, E; Miyagi, Y

    2009-01-01

    Background: Thromboembolic events are a major complication in ovarian cancer patients. Tissue factor (TF) is frequently overexpressed in ovarian cancer tissue and correlates with intravascular thrombosis. TF binds to coagulation factor VII (fVII), changing it to its active form, fVIIa. This leads to activation of the extrinsic coagulation cascade. fVII is produced by the liver and believed to be supplied from blood plasma at the site of coagulation. However, we recently showed that ovarian ca...

  4. Modelling of the Blood Coagulation Cascade in an In Vitro Flow System

    DEFF Research Database (Denmark)

    Andersen, Nina Marianne; Sørensen, Mads Peter; Efendiev, Messoud A.

    2010-01-01

    We derive a mathematical model of a part of the blood coagulation cascade set up in a perfusion experiment. Our purpose is to simulate the influence of blood flow and diffusion on the blood coagulation pathway. The resulting model consists of a system of partial differential equations taking...... and flow equations, which guarantee non negative concentrations at all times. The criteria is applied to the model of the blood coagulation cascade....

  5. Treatment of sugar beet extraction juice stillage by natural coagulants extracted from common bean

    OpenAIRE

    Prodanović Jelena M.; Šćiban Marina B.; Antov Mirjana G.; Kukić Dragana V.; Vasić Vesna M.

    2015-01-01

    Distillery wastewaters have a great pollution potential, and pollution caused by them is one of the most critical environmental issues. This study is concerned with the coagulation efficiency of a new, environmental friendly, natural coagulant extracted from common bean seeds in the primary treatment of distillery wastewater in the bioethanol production from sugar beet juice. Active coagulation components were extracted from ground seeds of common bean with...

  6. Comparative thermometric coagulation studies of plasmas from normal outbred Swiss Webster mice and persons.

    Science.gov (United States)

    Tsang, V C; Wyatt, C R; Damian, R T

    1979-06-01

    The functional capabilities of a thermometric clot-timer have been demonstrated in a comparative study of human and mouse plasma coagulation. The influence of some variables on coagulation times of mouse and human plasmas were examined in activated partial thromboplastin time, one-stage prothrombin time, and Russell's viper venom time assays. Mouse plasma coagulation times were generally shorter and more reproducible than those of human plasma. Optimal assay conditions are also described.

  7. Influence of ionizing radiation and 12-crown-4 on coagulation system components of rat blood

    International Nuclear Information System (INIS)

    Kratenko, R.Yi.

    2006-01-01

    The influence of 12-crown-4 and ionizing radiation on some components of blood coagulation system: Ca 2+ contents and prostaglandin concentrations in the blood serum, and erythrocyte contents in the blood plasma are studied. The influence of 12-crown-4 and ionizing radiation increases the coagulational properties of erythrocytes. The synergism of ionizing irradiation and 12-crown-4 influence blood coagulation process points out at the occurrence of radiomimetic properties of the latter

  8. Removal of natural organic matter in drinking water treatment by coagulation: A comprehensive review.

    Science.gov (United States)

    Sillanpää, Mika; Ncibi, Mohamed Chaker; Matilainen, Anu; Vepsäläinen, Mikko

    2018-01-01

    Natural organic matter (NOM) is a complex matrix of organic substances produced in (or channeled to) aquatic ecosystems via various biological, geological and hydrological cycles. Such variability is posing a serious challenge to most water treatment technologies, especially the ones designed to treat drinking water supplies. Lately, in addition to the fluctuating composition of NOM, a substantial increase of its concentration in fresh waters, and also municipal wastewater effluents, has been reported worldwide, which justifies the urgent need to develop highly efficient and versatile water treatment processes. Coagulation is among the most applied processes for water and wastewater treatment. The application of coagulation to remove NOM from drinking water supplies has received a great deal of attention from researchers around the world because it was efficient and helped avoiding the formation of disinfection by products (DBPs). Nonetheless, with the increased fluctuation of NOM in water (concentration and composition), the efficiency of conventional coagulation was substantially reduced, hence the need to develop enhanced coagulation processes by optimizing the operating conditions (mainly the amount coagulants and pH), developing more efficient inorganic or organic coagulants, as well as coupling coagulation with other water treatment technologies. In the present review, recent research studies dealing with the application of coagulation for NOM removal from drinking water supplies are presented and compared. In addition, integration schemes combining coagulation and other water treatment processes are presented, including membrane filtration, oxidation, adsorption and others processes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Using Coagulation Process in Optimizing Natural Organic Matter Removal from Low Turbidity Waters

    Directory of Open Access Journals (Sweden)

    Alireza Mesdaghinia

    2006-03-01

    Full Text Available Optimization of coagulation process  for efficient removal of Natural Organic Matters (NOM has gained a lot of focus over the last years to meet the requirements of enhanced coagulation. NOM comprises both particulate and soluble components which the latter usually comprises the main portion. Removal of soluble NOM from low turbidity waters by coagulation is not a successful process unless enough attention is paid to stages of formation and development of both micro and macro-flocs. This study, which presents experimental results from pilot scale research studies aimed at optimizing coagulation process applied to synthetic raw waters supplemented by adding commercial humic acid with low turbidity levels, explains how pH and turbidity can be controlled to maximize soluble NOM removal. The removal of NOM at various coagulant doses and coagulation pHs has been assessed through raw and treated (coagulated-settled water measurements of total organic carbon (TOC. For low turbidity waters, essential floc nucleation sites can be provided by creating synthetic turbidities, for example by adding clay. Adjusting the initial pH at 5.5 or adding clay before coagulant addition allows the formation of micro-flocs as well as formation of the insoluble flocs at low coagulant doses.

  10. Coagulation mechanism of salt solution-extracted active component in Moringa oleifera seeds.

    Science.gov (United States)

    Okuda, T; Baes, A U; Nishijima, W; Okada, M

    2001-03-01

    This study focuses on the coagulation mechanism by the purified coagulant solution (MOC-SC-PC) with the coagulation active component extracted from M. oleifera seeds using salt solution. The addition of MOC-SC-PC tap water formed insoluble matters. This formation was responsible for kaolin coagulation. On the other hand, insoluble matters were not formed when the MOC-SC-PC was added into distilled water. The formation was affected by Ca2+ or other bivalent cations which may connect each molecule of the active coagulation component in MOC-SC-PC and form a net-like structure. The coagulation mechanism of MOC-SC-PC seemed to be an enmeshment of Kaolin by the insoluble matters with the net-like structure. In case of Ca2+ ion (bivalent cations), at least 0.2 mM was necessary for coagulation at 0.3 mgC l-1 dose of MOC-SC-PC. Other coagulation mechanisms like compression of double layer, interparticle bridging or charge neutralization were not responsible for the coagulation by MOC-SC-PC.

  11. Coagulation mechanism of salt solution-extracted active component in Moringa oleifera seeds

    OpenAIRE

    Okuda, Tetsuji; Baes, Aloysius U.; Nishijima, Wataru; Okada, Mitsumasa

    2001-01-01

    This study focuses on the coagulation mechanism by the purified coagulant solution (MOC-SC-PC) with the coagulation active component extracted from M. oleifera seeds using salt solution. The addition of MOC-SC-PC into tap water formed insoluble matters. The formation was responsible for kaolin coagulation. On the other hand, insoluble matters were not formed when the MOC-SC-PC was added into distilled water. The formation was affected by Ca2+ or other bivalent cations which may connect each m...

  12. Application of Moringa Oleifera Seed Powder for Iron (III) Coagulation on Local Water Resources

    OpenAIRE

    Prasetyaningtyas, Fadillah Utami; Rumhayati, Barlah; Masruri, Masruri

    2013-01-01

    This research aims to know the effect of the use of powder moringa seed to coagulant mass and coagulation process, and its effectiveness to increase the quality of pure water. This research uses factorial research design and statistic test MANOVA. To analyse water quality, the researcher uses Fe parameter.  A graphic of coagulant mass and time for each parameter is used to analyse the data. Based on the research result, the uses of moringa seed as coagulant in each 300 mL mineral water gives ...

  13. Gas-liquid contacting in mixing vessels

    International Nuclear Information System (INIS)

    Mann, R.

    1983-01-01

    This report by Dr. R. Mann of UMIST presents a critical survey of literature on the contacting of gases with liquids in stirred vessels. Research undertaken in the last fifteen years in analysed, and promising areas for future research are identified. The report deals with physical contacting, mass transfer between the gas and liquid phases and the utilisation of the stirred vessel as a gas-liquid reactor. Three sections are given on gas-liquid contacting: physical aspects; interphase mass transfer; and chemical reactions. It also discusses recent new approaches and includes a summary of conclusions, nomenclature and references

  14. Comparison of the Performance of Corn Starch Coagulant Aid Accompany with Alum, Polyaluminum Chloride and Ferric Chloride Coagulants in Turbidity Removal from Water

    Directory of Open Access Journals (Sweden)

    Leila Mosleh

    2014-09-01

    Full Text Available Background: The most important process in water treatment plant is coagulation and flocculation. Regular chemical coagulant which used in Iran are aluminum sulfate (Alum and ferric chloride. Chemical coagulants have hazardous effect on human health and their cost is high for developing country. The purpose of this study was to evaluate the comparison of chemical coagulants accompany with corn starch as a coagulant aid, for the turbidity removal from water. Methods: This study was accomplished in pilot-scale with synthetic turbid water using clay. In this research, initial turbidity of 250 and 500 NTU was experimented. Chemical coagulant dose during the experiment was 1, 2 and 5 ppm and natural coagulant dose was 0, 0.1, 0.3, 0.5 and 0.7 ppm. Results: The results showed that maximum removal efficiency of turbidity in initial turbidity of 250 NTU belonged to poly aluminum chloride with 5 ppm dosage and corn starch with 0.7 ppm dosage which removed and reduced the initial turbidity to 98.48% and 3.73 NTU, respectively. Moreover, in initial turbidity of 500 NTU the maximum removal efficiency was 98.52% which belonged to ferric chloride and corn starch (5 and 0.7 ppm respectively and reduced the initial turbidity to 7.4 NTU. Conclusions: The results of this study showed that using natural coagulant aid reduce the chemical coagulant consumption, and also does not have significant effect on pH range and reduce the health risks. While huge amount of required polyelectrolytes for water treatment plant imported to the country and the production of corn starch in our country is high, it is hope that the results of this project can be used in industrial scale.

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... eye-care professional. Retailers that sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. "Many of the lenses found online or in beauty salons, novelty shops or in pop-up ... contact lenses from a retailer that does not ask for a prescription. ...

  16. Electric contact arcing

    International Nuclear Information System (INIS)

    Cuthrell, R.E.

    1976-01-01

    Electrical contacts must function properly in many types of components used in nuclear weapon systems. Design, application, and testing of these components require detailed knowledge of chemical and physical phenomena associated with stockpile storage, stockpile testing, and operation. In the past, investigation of these phenomena has led to significant discoveries on the effects of surface contaminants, friction and wear, and the mechanics of closure on contact performance. A recent investigation of contact arcing phenomena which revealed that, preceding contact closure, arcs may occur at voltages lower than had been previously known is described. This discovery is important, since arcing may damage contacts, and repetitive testing of contacts performed as part of a quality assurance program might produce cumulative damage that would yield misleading life-test data and could prevent proper operation of the contacts at some time in the future. This damage can be avoided by determining the conditions under which arcing occurs, and ensuring that these conditions are avoided in contact testing

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Get follow up exams with your eye care provider. If you notice redness, swelling, excessive discharge, pain or discomfort from wearing contact lenses, remove the lenses and seek immediate medical attention from an ophthalmologist. Related resources: Learn how to properly care for contact lenses . ...

  18. Sciences & Nature: Contact

    African Journals Online (AJOL)

    Principal Contact. Ehouan Etienne Ehile Professor University of Abobo-Adjamé 02 BP 801 Abidjan 02. Phone: (+225) 2030 4201. Fax: (+225) 2030 4203. Email: eh_ehile@yahoo.fr. Support Contact. Irie Zoro Bi Email: banhiakalou@yahoo.fr. ISSN: 1812-0741. AJOL African Journals Online. HOW TO USE AJOL.

  19. Contact Us | DOepatents

    Science.gov (United States)

    advance. Your help is appreciated. Contact us by email Email doepatentscomments@osti.gov NOTE: Email us by phone Phone Phone (865) 241-5275 Contact us in writing Mail U.S. Department of Energy Office of non-federal websites. Their policies may differ from this site. Javascript Not Enabled Email Link

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... eye-care team . Consumer warning about the improper use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering buying approved by the FDA? Check the FDA's database of approved contact lenses . Related Stories Prevent Infection ...

  1. Contact dermatitis. A review

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Benezra, C; Burrows, D

    1987-01-01

    In recent years, there has been a dramatic rise in our understanding of contact dermatitis. This paper is a review of our knowledge of the mechanisms involved in contact dermatitis and related phenomena, the investigation of these events and the emergence of significant new allergens during...

  2. Contact Hamiltonian mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Bravetti, Alessandro, E-mail: alessandro.bravetti@iimas.unam.mx [Instituto de Investigaciones en Matemáticas Aplicadas y en Sistemas, Universidad Nacional Autónoma de México, A. P. 70543, México, DF 04510 (Mexico); Cruz, Hans, E-mail: hans@ciencias.unam.mx [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, A. P. 70543, México, DF 04510 (Mexico); Tapias, Diego, E-mail: diego.tapias@nucleares.unam.mx [Facultad de Ciencias, Universidad Nacional Autónoma de México, A.P. 70543, México, DF 04510 (Mexico)

    2017-01-15

    In this work we introduce contact Hamiltonian mechanics, an extension of symplectic Hamiltonian mechanics, and show that it is a natural candidate for a geometric description of non-dissipative and dissipative systems. For this purpose we review in detail the major features of standard symplectic Hamiltonian dynamics and show that all of them can be generalized to the contact case.

  3. Contact Quality in Participation

    DEFF Research Database (Denmark)

    Simonsen, Jesper; Jensen, Olav Storm

    2016-01-01

    We investigate the concept of participation from the perspective of quality of the contact in the communicative interactions between participants. We argue for the need for an academic-personal competence that qualifies the human contact central in all Participatory Design (PD) activities as a way...

  4. Nigerian Food Journal: Contact

    African Journals Online (AJOL)

    Nigerian Food Journal. ... Nigerian Food Journal: Contact. Journal Home > About the Journal > Nigerian Food Journal: Contact. Log in or Register to get access to full text downloads. ... Mailing Address. Department of Food Science and Technology University of Agriculture, Makurdi, Nigeria ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to enhance their costumes. From ... MD, professor of ophthalmology at Case Western Reserve University in Cleveland. "This is far ... Use Facts About Colored Contacts and Halloween Safety Colored ...

  6. Bloodcurdling movies and measures of coagulation: Fear Factor crossover trial.

    Science.gov (United States)

    Nemeth, Banne; Scheres, Luuk J J; Lijfering, Willem M; Rosendaal, Frits R

    2015-12-16

    To assess whether, as has been hypothesised since medieval times, acute fear can curdle blood. Crossover trial. Main meeting room of Leiden University's Department of Clinical Epidemiology, the Netherlands, converted to a makeshift cinema. 24 healthy volunteers aged ≤30 years recruited among students, alumni, and employees of the Leiden University Medical Center: 14 were assigned to watch a frightening (horror) movie followed by a non-threatening (educational) movie and 10 to watch the movies in reverse order. The movies were viewed more than a week apart at the same time of day and both lasted approximately 90 minutes. The primary outcome measures were markers, or "fear factors" of coagulation activity: blood coagulant factor VIII, D-dimer, thrombin-antithrombin complexes, and prothrombin fragments 1+2. The secondary outcome was participant reported fear experienced during each movie using a visual analogue fear scale. All participants completed the study. The horror movie was perceived to be more frightening than the educational movie on a visual analogue fear scale (mean difference 5.4, 95% confidence interval 4.7 to 6.1). The difference in factor VIII levels before and after watching the movies was higher for the horror movie than for the educational movie (mean difference of differences 11.1 IU/dL (111 IU/L), 95% confidence interval 1.2 to 21.0 IU/dL). The effect of either movie on levels of thrombin-antithrombin complexes, D-dimer, and prothrombin fragments 1+2 did not differ. Frightening (in this case, horror) movies are associated with an increase of blood coagulant factor VIII without actual thrombin formation in young and healthy adults. Trial registration ClinicalTrials.gov NCT02601053. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Coagulation abnormalities in patients with chronic liver disease in Pakistan

    International Nuclear Information System (INIS)

    Siddiqui, S.A.; Ghani, M.H.; Ghori, M.A.; Ahmed, M.

    2011-01-01

    Objective: To determine the coagulation abnormalities and relationship between abnormal clotting tests and the risk of gastrointestinal bleeding (GI) among chronic liver disease (CLD) patients admitted at a tertiary care hospital in Pakistan. Methods: Adult CLD patients admitted at Liaquat University Hospital Jamshoro, during Nov 2004 - Oct 2005, were included in the study. The patients blood were tested for coagulation abnormalities including prothrombin time (PT), activated partial thromboplastin time (aPTT), platelet count and plasma fibrinogen. Association was seen between the abnormal clotting tests and the gastrointestinal bleeding by calculating relative risk (RR) with 95% confidence interval. Results: PT was prolonged in 88% and aPTT was raised in 71% cases of CLD. Both PT and aPTT were prolonged in 67% CLD cases. Approximately 37% CLD cases had decreased platelet count and 15% cases had decreased serum fibrinogen level. Relative risk of GI bleeding with abnormal clotting tests in CLD cases were weakly positive for PT (RR = 1.02; 95% CI, 0.49-2.10), negative for aPTT (RR=0.83; 95% CI, 0.47-1.45), strongly positive for decreased platelet counts (RR = 1.96; 95% CI, 1.08-3.56) and also for decreased fibrinogen level (RR = 1.47; 95% CI, 0.64-3.35). Conclusion: Coagulation abnormalities were profound in CLD. Decrease platelet counts and fibrinogen levels were related with GI bleeding but PT and aPTT were not significantly related with GI bleeding in patients with chronic liver disease. Nevertheless, these parameters (PT and aPTT) were still used as prognostic markers. (author)

  8. Coagulation of Agglomerates Consisting of Polydisperse Primary Particles.

    Science.gov (United States)

    Goudeli, E; Eggersdorfer, M L; Pratsinis, S E

    2016-09-13

    The ballistic agglomeration of polydisperse particles is investigated by an event-driven (ED) method and compared to the coagulation of spherical particles and agglomerates consisting of monodisperse primary particles (PPs). It is shown for the first time to our knowledge that increasing the width or polydispersity of the PP size distribution initially accelerates the coagulation rate of their agglomerates but delays the attainment of their asymptotic fractal-like structure and self-preserving size distribution (SPSD) without altering them, provided that sufficiently large numbers of PPs are employed. For example, the standard asymptotic mass fractal dimension, Df, of 1.91 is attained when clusters are formed containing, on average, about 15 monodisperse PPs, consistent with fractal theory and the literature. In contrast, when polydisperse PPs with a geometric standard deviation of 3 are employed, about 500 PPs are needed to attain that Df. Even though the same asymptotic Df and mass-mobility exponent, Dfm, are attained regardless of PP polydispersity, the asymptotic prefactors or lacunarities of Df and Dfm increase with PP polydispersity. For monodisperse PPs, the average agglomerate radius of gyration, rg, becomes larger than the mobility radius, rm, when agglomerates consist of more than 15 PPs. Increasing PP polydispersity increases that number of PPs similarly to the above for the attainment of the asymptotic Df or Dfm. The agglomeration kinetics are quantified by the overall collision frequency function. When the SPSD is attained, the collision frequency is independent of PP polydispersity. Accounting for the SPSD polydispersity in the overall agglomerate collision frequency is in good agreement with that frequency from detailed ED simulations once the SPSD is reached. Most importantly, the coagulation of agglomerates is described well by a monodisperse model for agglomerate and PP sizes, whereas the detailed agglomerate size distribution can be obtained by

  9. Contact materials for nanoelectronics

    KAUST Repository

    Alshareef, Husam N.

    2011-02-01

    In this article, we review current research activities in contact material development for electronic and nanoelectronic devices. A fundamental issue in contact materials research is to understand and control interfacial reactions and phenomena that modify the expected device performance. These reactions have become more challenging and more difficult to control as new materials have been introduced and as device sizes have entered the deep nanoscale. To provide an overview of this field of inquiry, this issue of MRS Bulletin includes articles on gate and contact materials for Si-based devices, junction contact materials for Si-based devices, and contact materials for alternate channel substrates (Ge and III-V), nanodevices. © 2011 Materials Research Society.

  10. Rare coagulation disorders: fibrinogen, factor VII and factor XIII.

    Science.gov (United States)

    de Moerloose, P; Schved, J-F; Nugent, D

    2016-07-01

    Rare coagulation disorders (RCDs) include the inherited deficiencies of fibrinogen, factor (F) II, FV, combined FV and VIII, FVII, FX, combined FVII and X, FXI, FXIII and combined congenital deficiency of vitamin K-dependent factors (VKCFDs). Despite their rarity, a deep comprehension of all these disorders is essential to really understand haemostasis. Indeed, even if they share some common features each RCD has some particularity which makes it unique. In this review, we focus on three disorders: fibrinogen, FVII and FXIII. © 2016 John Wiley & Sons Ltd.

  11. Evaluation of Coagulation Profiles in Dogs with Septic Shock

    OpenAIRE

    YILMAZ, Zeki; YALÇIN, Ebru

    2002-01-01

    The aim of the this study was to observe possible changes in coagulation profiles in dogs with septic shock. A total of 30 dogs (control group n=10, test group n=20) were used as materials in this study. Although different diseases leading to septic shock were diagnosed in dogs in the test group, dogs were selected on the basis of septic shock criteria such as fever or hypothermia, hypotension, leukopenia or leukocytosis and thrombocytopenia. In addition to the results of rutine clinical and...

  12. Structural and functional studies on human coagulation factor V

    OpenAIRE

    Neut Kolfschoten, Marijn van der

    2005-01-01

    The aim of this research was to obtain a better insight into the structure and functioning of clotting factor V (FV), a protein that plays an important role in the regulation of clotting. Congenital defects in FV can greatly disturb the coagulation system, and can lead to symptoms ranging from para-haemophilia to thrombosis. One example of a congenital defect in FV I is the R506Q mutation (an aminoacid change at position 506 in the aminoacid chain of FV). This deviating FV molecule (also know...

  13. Numerical simulations of a reduced model for blood coagulation

    Science.gov (United States)

    Pavlova, Jevgenija; Fasano, Antonio; Sequeira, Adélia

    2016-04-01

    In this work, the three-dimensional numerical resolution of a complex mathematical model for the blood coagulation process is presented. The model was illustrated in Fasano et al. (Clin Hemorheol Microcirc 51:1-14, 2012), Pavlova et al. (Theor Biol 380:367-379, 2015). It incorporates the action of the biochemical and cellular components of blood as well as the effects of the flow. The model is characterized by a reduction in the biochemical network and considers the impact of the blood slip at the vessel wall. Numerical results showing the capacity of the model to predict different perturbations in the hemostatic system are discussed.

  14. Endobronchial Electrocautery and Argon Plasma Coagulation: A Practical Approach

    Directory of Open Access Journals (Sweden)

    Alain Tremblay

    2004-01-01

    Full Text Available The present review covers the technical and practical aspects of endobronchial electrocautery, including argon plasma coagulation, which have great potential for widespread use by pulmonologists around the world. The various electrocautery modes, power settings and electrode probes are described in detail, and the authors' clinical and technical approach is demonstrated with a narrative description and brief case presentations. Malignant airway obstruction, hemoptysis, web-like stenosis, stent related granulation tissue and early lung carcinomas are the most common indications for treatment. Advantages of electrocautery, such as low cost, rapid effect, safety and ease of use, are contrasted to other endobronchial therapeutic modalities. Published experience with electrocautery is reviewed.

  15. The effects of chemical coagulants on the decolorization of dyes by electrocoagulation using response surface methodology (RSM)

    Science.gov (United States)

    Butler, Erick B.; Hung, Yung-Tse; Mulamba, Oliver

    2017-09-01

    This study assessed the efficiency of electrocoagulation (ECF) coupled with an addition of chemical coagulant to decolorize textile dye. Tests were conducted using Box Behnken methodology to vary six parameters: dye type, weight, coagulant type, dose, initial pH and current density. The combination of electrocoagulation and chemical coagulation was able to decolorize dye up to 99.42 % in 30 min of treatment time which is remarkably shorter in comparison with using conventional chemical coagulation. High color removal was found to be contingent upon the dye type and current density, along with the interactions between the current density and the coagulant dose. The addition of chemical coagulants did enhanced treatment efficiency.

  16. An organic-inorganic hybrid coagulant containing Al, Zn and Fe (HOAZF: preparation, efficiency and mechanism of removing organic phosphorus

    Directory of Open Access Journals (Sweden)

    Y. Fu

    2018-04-01

    Full Text Available A polymeric-Al-Zn-Fe (PAZF coagulant showing high removal of pollutants has been successfully developed using a galvanized slag in earlier works, but it gave less elimination of phosphorus. To improve phosphorus removal, a hybrid organic-Al-Zn-Fe (HOAZF coagulant was prepared using PAZF and polyacrylamide (PAM as an organic additive, and then was characterized by scanning electron microscopy (SEM, infrared spectroscopy (IR, X-ray diffraction (XRD, and Zeta potential, respectively. Removing efficiency and mechanism of organophosphorus by HOAZF was probed using jar tests in treating a simulated pesticide wastewater containing dichlorvos (DDVP, compared to that by PAZF and polyaluminum chloride. The results displayed that HOAZF having relative lower Zeta potential (compared to PAZF exhibited complex surface morphology composited by Al, Zn and Fe and PAM, forming some new crystalline and amorphous substances different from that in PAZF. HOAZF gave higher removal of organophosphorus and far lower dosage than PAZF, and also posed a suitable wider pH range (pH = 7–12 for HOAZF and 10–11 for PAZF, respectively and suitable wider organophosphorus level range than PAZF. Removing organophosphorus by HOAZF was a simultaneous complex process involving a non-phase transfer of adsorption/bridging/sweeping and a phase transfer of chemical precipitation.

  17. Use of non-Conventional Material to Remove Cu+2 ions from Aqueous Solutions using Chemical Coagulation

    Directory of Open Access Journals (Sweden)

    Muna Yousif Abdul. Ahad

    2015-05-01

    Full Text Available Coagulation - flocculation are basic chemical engineering method in the treatment of metal-bearing industrial wastewater because it removes colloidal particles, some soluble compounds and very fine solid suspensions initially present in the wastewater by destabilization and formation of flocs. This research was conducted to study the feasibility of using natural coagulant such as okra and mallow and chemical coagulant such as alum for removing Cu and increase the removal efficiency and reduce the turbidity of treated water. Fourier transform Infrared (FTIR was carried out for okra and mallow before and after coagulant to determine their type of functional groups. Carbonyl and hydroxyl functional groups on the surface of okra and mallow were the major groups responsible for coagulation process. By using alum (conventional coagulants, okra and mallow (as a primary coagulant or in combination with the other two primary coagulants and by the jar testing, the optimum pH-value and dose of the coagulants were determined. The results indicated that the optimal pH values were 6.7, 8 and 6 for alum, okra and mallow, respectively. Mathematical modeling show significant results (sig.<0.05 for the % Cu removal (dependent variable with respect to coagulant dose (independent variable for the okra as a primary coagulant, alum with okra and alum with mallow as binary coagulants and alum, okra and mallow as ternary coagulants .

  18. Contacts to semiconductors

    International Nuclear Information System (INIS)

    Tove, P.A.

    1975-08-01

    Contacts to semiconductors play an important role in most semiconductor devices. These devices range from microelectronics to power components, from high-sensitivity light or radiation detectors to light-emitting of microwave-generating components. Silicon is the dominating material but compound semiconductors are increasing in importance. The following survey is an attempt to classify contact properties and the physical mechanisms involved, as well as fabrication methods and methods of investigation. The main interest is in metal-semiconductor type contacts where a few basic concepts are dealt with in some detail. (Auth.)

  19. Thyroid storm complicated by bicytopenia and disseminated intravascular coagulation.

    Science.gov (United States)

    Tokushima, Yoshinori; Sakanishi, Yuta; Nagae, Kou; Tokushima, Midori; Tago, Masaki; Tomonaga, Motosuke; Yoshioka, Tsuneaki; Hyakutake, Masaki; Sugioka, Takashi; Yamashita, Shu-ichi

    2014-07-24

    Male, 23. Thyroid storm. Delirium • diarrhea • fever • hypertension • hyperventilation • tachycardia • weight loss. -. -. Endocrinology and Metabolic. Unusual clinical course. The clinical presentation of thyroid storm includes fever, tachycardia, hypertension, and neurological abnormalities. It is a serious condition with a high mortality rate. Furthermore, some other complications affect the clinical course of thyroid storm. Although it is reported that prognosis is poor when thyroid storm is complicated by disseminated intravascular coagulation syndrome (DIC) and leukopenia, reports of such cases are rare. A 23-year-old man presented with delirium, high pyrexia, diarrhea, and weight loss of 18 kg over 2 months. According to the criteria of Burch and Wartofsky, he was diagnosed with thyroid storm on the basis of his symptom-complex and laboratory data that confirmed the presence of hyperthyroidism. Investigations also found leukopenia, thrombocytopenia, and disseminated intravascular coagulation, all of which are very rare complications of thyroid storm. We successfully treated him with combined therapy including anti-thyroid medication, despite leukopenia. Early diagnosis and treatment are essential in ensuring a good outcome for patients with this rare combination of medical problems.

  20. Effect of flomoxef on blood coagulation and alcohol metabolism.

    Science.gov (United States)

    Uchida, K; Matsubara, T

    1991-01-01

    The effect of flomoxef, a newly developed oxacephem antibiotic with an N-hydroxyethyltetrazolethiol (HTT) side chain, on blood coagulation and alcohol metabolism was compared with that of a series of cephalosporin antibiotics with N-methyltetrazolethiol (NMTT), thiadiazolethiol (TDT) or methylthiadiazolethiol (MTDT) side chains in position 3' of the cephalosporin nucleus known to cause hypoprothrombinemia and bleeding in patients who are malnourished, debilitated and/or of high age. A disulfiram-like effect caused by inhibition of aldehyde dehydrogenase was observed for NMTT-containing antibiotics. Studies were carried out on healthy volunteers and on rats. Eight-day treatment with 2 g flomoxef i.v. once or twice daily in five and six healthy male volunteers, respectively, did not cause any significant changes in prothrombin time (PT), coagulation factors II, VII, IX or X, in hepaplastin values or fibrinogen levels, activated partial thromboplastin time (APTT), platelet counts, bleeding time, or collagen- and ADP-induced platelet aggregation. Inhibition of vitamin K epoxide reductase was observed in rats treated with flomoxef, yet to a much lesser extent than observed for cephalosporins with NMTT, TDT or MTDT side chains. This defect was quickly normalized by vitamin K injection. There were no differences between oxacephem (1-O) and cephem (1-S) compounds with respect to effects on blood clotting and platelet aggregation. Flomoxef and its side chain HTT showed no influence on alcohol metbolism.

  1. Intraventricular hemorrhage in preterm infants and coagulation--ambivalent perspectives?

    Science.gov (United States)

    Kuperman, Amir A; Brenner, Benjamin; Kenet, Gili

    2013-01-01

    Intraventricular hemorrhage (IVH) is a major complication of preterm birth, and large hemorrhages may yield significant future disability. During the last few decades, the survival of preterm infants has increased dramatically. Nevertheless, morbidity is still a major problem especially for very young and extremely low birth weight infants. As both, mortality and incidence of morbidities known to influence outcome, show a weekly decline with increasing gestational age, prematurity and low birth weight have been identified as major risk factors for IVH occurrence. This stems probably from the increased vulnerability of the premature germinal matrix as well as the physiologically impaired hemostasis, demonstrated in neonates. The hypothesis that a severe coagulation deficiency in the premature newborn could be a major contributing factor for IVH has been suggested, and small open label interventional studies targeting the premature coagulation system have been conducted with ethamsylate, vitamin K, fresh frozen plasma, recombinant activated factor VII and prothrombin complex concentrate. Nevertheless, potential venous origin of hemorrhages, which may be related to thrombophilic risk factors, has also been discussed. The following manuscript will focus upon IVH pathogenesis and address potential therapies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Dosimetry for photo-coagulation by the use of autofluorescence

    Science.gov (United States)

    Brodzinski, T.

    1989-01-01

    A basic problem when using lasers in medicine is that of dosimetry. The definition of the terms dose, effective value etc. will be dealt with in Chapter 2. This chapter is intended to give an insight into the problems of basic dosimetry and its technical realization within the field of photocoagulation, an established method used to treat the retina, or some skin diseases. Until now the coagulation process was assessed to be completed when the irradiated area became blanched. However in terms of dosimetry, it must be possible to predict or at least to monitor the biological effect using well-defined parameters for the laser or in achieving an objective measure for a feedback loop. In the case of coagulation, a prediction in this form is not possible. There are two ways of pro- ceeding further see Fig. 1. One can either determine the physical effect, i.e. temperature, by some kind of sensors, or even better, use some biological effect as a direct measure of the effective dose applied.

  3. [Influence of Gentiana lutea L extract on blood coagulation].

    Science.gov (United States)

    Bakuridze, A D; Nikolaev, S M; Tsagarenshvili, N T; Kurdiani, N G; Mikaia, G A

    2009-01-01

    The dry extract from the terrestrial parts of Gentiana Lutea was received in accordance to the developed by us general technological scheme. Study of the pharmacological influence of obtained extract on the coagulating properties of blood revealed that after its per os instillation into experimental animals the time of the formation of active thromboplastin reliably increases, while the time of thrombin and fibrinous cluster formation is shortened in comparison with those indices in the animals, that did not receive phyto-preparation, at the same time morphological appearance of the peripheral blood remains unchanged. Dry extract of terrestrial parts of Gentiana Lutea prepared in accordance to the technology recommended by us, together with widely known pharmacological effects, is characterized with new activity - influence on haemostasis. Obtained preliminary data concerning influence of the extract on coagulation of the blood request further deep studies of its mechanism. Revealed new activity of the terrestrial parts of Gentiana Lutea and the studies of the mechanism of its activity will serve in future as a basis for the recommendation of its use in new nosology. Terrestrial parts of Gentiana lutea L. are proposed as an alternative of the underground parts of the plant. Alongside with that, it is expedient to continue the studies devoted to the development of the haemostatic remedies of plant origin with systemic and local action (sponges, films, skin glues) from terrestrial parts of Gentiana lutea L.

  4. The influence of hydraulic conditions on coagulation process effectiveness

    Directory of Open Access Journals (Sweden)

    Sambor Aleksandra

    2017-01-01

    Full Text Available This paper presents the impact that small changes in the hydraulic installation between the flocculation chamber and the sedimentation tanks have on coagulation process effectiveness. This study has shown significant improvements in the parameters of the treated water. The research was conducted in two treatment systems: reference and test, in order to compare the changes that were introduced in the time period between January and May 2016. The hydraulic conditions between the flocculation chamber and the sedimentation tank were changed in the test system, leaving the reference system unchanged for comparative purposes. The height-wise positioning of the sedimentation tank relative to the flocculation chamber resulted in a formation of a cascade at the flocculation chamber drain at a height of 0.60m. Air was therefore introduced into the water, forming an air-water mixture, which disturbed the flow between the devices. It was found that floc transported by the pipeline was broken down, which hampered sedimentation in the sedimentation tank. This was confirmed by the analysis of chosen parameters from treated water. After changes in the hydraulic system, changes in water turbidity were noticed, indicating an increase in post-coagulation suspension separation effectiveness. Consequently, an increase in organic carbon removal was found relative to the reference system. This change influenced changes in UV254 absorbance to a much lesser extent.

  5. The influence of hydraulic conditions on coagulation process effectiveness

    Science.gov (United States)

    Sambor, Aleksandra; Ferenc, Zbigniew

    2017-11-01

    This paper presents the impact that small changes in the hydraulic installation between the flocculation chamber and the sedimentation tanks have on coagulation process effectiveness. This study has shown significant improvements in the parameters of the treated water. The research was conducted in two treatment systems: reference and test, in order to compare the changes that were introduced in the time period between January and May 2016. The hydraulic conditions between the flocculation chamber and the sedimentation tank were changed in the test system, leaving the reference system unchanged for comparative purposes. The height-wise positioning of the sedimentation tank relative to the flocculation chamber resulted in a formation of a cascade at the flocculation chamber drain at a height of 0.60m. Air was therefore introduced into the water, forming an air-water mixture, which disturbed the flow between the devices. It was found that floc transported by the pipeline was broken down, which hampered sedimentation in the sedimentation tank. This was confirmed by the analysis of chosen parameters from treated water. After changes in the hydraulic system, changes in water turbidity were noticed, indicating an increase in post-coagulation suspension separation effectiveness. Consequently, an increase in organic carbon removal was found relative to the reference system. This change influenced changes in UV254 absorbance to a much lesser extent.

  6. PROJECT OF COAGULANT DISPENSER IN PULVERIZATION AERATOR WITH WIND DRIVE

    Directory of Open Access Journals (Sweden)

    Ewa Osuch

    2017-09-01

    Full Text Available Lakes are one of most important freshwater ecosystems, playing significant role in functioning of nature and human economy. Swarzędzkie Lake is good example of ecosystem, which in last half-century was exposed to the influence of strong anthropopressure. Direct inflow of sewage with large number of biogens coming to the lake with water of inflows caused distinct disturbance of its functioning. In autumn 2011 restoration begined on Swarzędzkie Lake for reduction of lake trophy and improvement of water quality. For achieving better and quicker effect, simultaneously combination of some methods was applied, among others method of oxygenation of over-bottom water with help of pulverization aerator and method of precise inactivation of phosphorus in water depths. Characterization and analysis of improved coagulant dispenser applying active substance only during work of pulverization aerator is the aim of this thesis. Principle of dispenser work, its structure and location in pulverization aerator were explained. It was stated, that introduction to water a factor initiating process of phosphorus inactivation causes significant reduction of mineral phosphorus in water and size of coagulant dose correlates with intensity of work of pulverization aerator with wind drive.

  7. Selective binding behavior of humic acid removal by aluminum coagulation.

    Science.gov (United States)

    Jin, Pengkang; Song, Jina; Yang, Lei; Jin, Xin; Wang, Xiaochang C

    2018-02-01

    The reactivity characteristics of humic acid (HA) with aluminium coagulants at different pH values was investigated. It revealed that the linear complexation reaction occurred between aluminum and humic acid at pH aluminum existed in the form of free aluminum and remained unreacted in the presence of HA until the concentration reached to trigger Al(OH) 3(s) formation. Differentiating the change of functional groups of HA by 1 H nuclear magnetic resonance spectroscopy and X-ray photoelectron spectra analysis, it elucidated that there was a selective complexation between HA and Al with lower Al dosage at pH 5, which was probably due to coordination of the activated functional groups onto aluminium. While almost all components were removed proportionally by sweep adsorption without selectivity at pH 7, as well as that with higher Al dosage at pH 5. This study provided a promising pathway to analyse the mechanism of the interaction between HA and metal coagulants in future. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Quality control in the development of coagulation factor concentrates.

    Science.gov (United States)

    Snape, T J

    1987-01-01

    Limitation of process change is a major factor contributing to assurance of quality in pharmaceutical manufacturing. This is particularly true in the manufacture of coagulation factor concentrates, for which presumptive testing for poorly defined product characteristics is an integral feature of finished product quality control. The development of new or modified preparations requires that this comfortable position be abandoned, and that the effect on finished product characteristics of changes to individual process steps (and components) be assessed. The degree of confidence in the safety and efficacy of the new product will be determined by, amongst other things, the complexity of the process alteration and the extent to which the results of finished product tests can be considered predictive. The introduction of a heat-treatment step for inactivation of potential viral contaminants in coagulation factor concentrates presents a significant challenge in both respects, quite independent of any consideration of assessment of the effectiveness of the viral inactivation step. These interactions are illustrated by some of the problems encountered with terminal dry heat-treatment (72 h. at 80 degrees C) of factor VIII and prothrombin complex concentrates manufactured by the Blood Products Laboratory.

  9. Challenges in Radiofrequency Pasteurization of Shell Eggs: Coagulation Rings.

    Science.gov (United States)

    Lau, Soon Kiat; Thippareddi, Harshavardhan; Jones, David; Negahban, Mehrdad; Subbiah, Jeyamkondan

    2016-10-01

    A total of 50 different configurations of simple radiofrequency (RF) heating at 27.12 MHz of a shell egg were simulated using a finite element model with the purpose of pasteurizing the egg. Temperature-dependent thermal and dielectric properties of the yolk, albumen, and shell were measured, fitted, and introduced into the model. A regression equation that relates the top electrode voltage to the gap between the electrodes and vertical position of the egg was developed. Simulation and experimental results had good agreement in terms of temperature deviation (root mean squared error ranged from 0.35 °C to 0.48 °C) and both results demonstrated the development of a "coagulation ring" around the air cell. The focused heating near the air cell of the egg prevented pasteurization of the egg due to its impact on quality (coagulation). Analysis of the electric field patterns offered a perspective on how nonuniform RF heating could occur in heterogeneous food products. The results can be used to guide development of RF heating for heterogeneous food products and further development of RF pasteurization of eggs. © 2016 Institute of Food Technologists®.

  10. Measuring contact area in a sliding human finger-pad contact.

    Science.gov (United States)

    Liu, X; Carré, M J; Zhang, Q; Lu, Z; Matcher, S J; Lewis, R

    2018-02-01

    The work outlined in this paper was aimed at achieving further understanding of skin frictional behaviour by investigating the contact area between human finger-pads and flat surfaces. Both the static and the dynamic contact areas (in macro- and micro-scales) were measured using various techniques, including ink printing, optical coherence tomography (OCT) and Digital Image Correlation (DIC). In the studies of the static measurements using ink printing, the experimental results showed that the apparent and the real contact area increased with load following a piecewise linear correlation function for a finger-pad in contact with paper sheets. Comparisons indicated that the OCT method is a reliable and effective method to investigate the real contact area of a finger-pad and allow micro-scale analysis. The apparent contact area (from the DIC measurements) was found to reduce with time in the transition from the static phase to the dynamic phase while the real area of contact (from OCT) increased. The results from this study enable the interaction between finger-pads and contact object surface to be better analysed, and hence improve the understanding of skin friction. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not been properly fitted by an eye care professional, the lenses stuck to my eye like a ... prescription and proper fitting by an eye-care professional. Retailers that sell contacts without a prescription are ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ... About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ... away without suffering an eye injury. However, the natural protective mechanisms of the eye – such as the ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ... a laser pointer several times, according to a report published this month in the New England Journal ...

  15. SAM Technical Contacts

    Science.gov (United States)

    These technical contacts are available to help with questions regarding method deviations, modifications, sample problems or interferences, quality control requirements, the use of alternative methods, or the need to address analytes or sample types.

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are ... this month in the New England Journal of Medicine. Unfortunately, this kind of injury is all too ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... a souvenir shop, but 10 hours after she first put in a pair of colored contact lenses, ... APR 24, 2018 By Kate Rauch In a first, scientists in China have created artificial photoreceptors to ...

  18. GAS-FOVEAL CONTACT

    DEFF Research Database (Denmark)

    Alberti, Mark; la Cour, Morten

    2018-01-01

    PURPOSE: To compare gas-foveal contact in face-down positioning (FDP) and nonsupine positioning (NSP), to analyze causes of gas-foveal separation and to determine how gas-foveal contact affects clinical outcome after idiopathic macular hole repair. METHODS: Single center, randomized controlled...... study. Participants with an idiopathic macular hole were allocated to either FDP or NSP. Primary outcome was gas-foveal contact, calculated by analyzing positioning in relation to intraocular gas fill. Positioning was measured with an electronic device recording positioning for 72 hours postoperatively....... RESULTS: Positioning data were available for 33/35 in the FDP group and 35/37 in the NSP group, thus results are based on 68 analyzed participants. Median gas-foveal contact was 99.82% (range 73.6-100.0) in the FDP group and 99.57% (range 85.3-100.0) in the NSP group (P = 0.22). In a statistical model...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Sep. 26, 2013 It started as an impulsive buy from a souvenir shop, but 10 hours after ... are being sold illegally," Dr. Steinemann said. Never buy colored contact lenses from a retailer that does ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ... 2018 By Dan T. Gudgel Do you know what the difference is between ophthalmologists and optometrists? A ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Halloween or any time of year, follow these guidelines: Get an eye exam from a licensed eye ... available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the ...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir shop, but ... require the same level of care or consideration as a standard contact lens because they can be ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... seek immediate medical attention from an ophthalmologist. Related resources: Learn how to properly care for contact lenses . ... have given blind patients some functional vision, using human embryonic stem cells. Two blind patients regained enough ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... that decorative lenses do not require the same level of care or consideration as a standard contact ... By Kate Rauch In a small but intriguing study, scientists in England have given blind patients some ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... MD, professor of ophthalmology at Case Western Reserve University in Cleveland. "This is far from the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lentes de contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir ... Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored contact lenses without ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... With Proper Contact Lens Care Apr 23, 2018 Solar Eclipse Inflicts Damage in the Shape of the ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human- ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... videos on your website Promotional materials for eye health observances EyeSmart resources are also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... valid prescription that includes the brand name, lens measurements, and expiration date. Purchase the colored contact lenses ... with human-made versions. U.S. News Highlights the Value of Ophthalmologists APR 20, 2018 By Dan T. ...

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... 13, 2017 Histoplasmosis Diagnosis Sep 01, 2017 How common is retinal detachment for people with high myopia? ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus ... Eye Health A-Z Symptoms Glasses & Contacts Tips & ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering buying approved by the ... Service For Advertisers For Media Ophthalmology Job Center © American ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About ...

  16. Ergonomics SA: Contact

    African Journals Online (AJOL)

    Principal Contact. Mrs June McDougall. Rhodes University. Department of Human Kinetics and Ergonomics. P.O. Box 94. Rhodes University. Grahamstown. 6140. Phone: +27 46 6038471. Email: j.mcdougall@ru.ac.za ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering buying approved by ... 23, 2018 Solar Eclipse Inflicts Damage in the Shape of ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... colored contact lenses to enhance their costumes. From blood-drenched vampire eyes to glow-in-the-dark ... properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... to the journals may be interrupted during this time. We are working to resolve the issue quickly ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... the United States. All contact lenses are medical devices that require a prescription and proper fitting by ... Care Apr 23, 2018 How long does it take the eye to go back to its original ...

  2. Tomato contact dermatitis

    DEFF Research Database (Denmark)

    Paulsen, Evy; Christensen, Lars P; Andersen, Klaus Ejner

    2012-01-01

    The tomato plant (Solanum lycopersicum) is an important crop worldwide. Whereas immediate-type reactions to tomato fruits are well known, contact dermatitis caused by tomatoes or tomato plants is rarely reported. The aims of this study were to present new data on contact sensitization to tomato...... plants and review the literature on contact dermatitis caused by both plants and fruits. An ether extract of tomato plants made as the original oleoresin plant extracts, was used in aimed patch testing, and between 2005 and 2011. 8 of 93 patients (9%) tested positive to the oleoresin extracts....... This prevalence is in accordance with the older literature that reports tomato plants as occasional sensitizers. The same applies to tomato fruits, which, in addition, may cause protein contact dermatitis. The allergens of the plant are unknown, but both heat-stable and heat-labile constituents seem...

  3. Fragrance allergic contact dermatitis.

    Science.gov (United States)

    Cheng, Judy; Zug, Kathryn A

    2014-01-01

    Fragrances are a common cause of allergic contact dermatitis in Europe and in North America. They can affect individuals at any age and elicit a spectrum of reactions from contact urticaria to systemic contact dermatitis. Growing recognition of the widespread use of fragrances in modern society has fueled attempts to prevent sensitization through improved allergen identification, labeling, and consumer education. This review provides an overview and update on fragrance allergy. Part 1 discusses the epidemiology and evaluation of suspected fragrance allergy. Part 2 reviews screening methods, emerging fragrance allergens, and management of patients with fragrance contact allergy. This review concludes by examining recent legislation on fragrances and suggesting potential additions to screening series to help prevent and detect fragrance allergy.

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Peligros asociados con los lentes de contacto de color Sep. 26, 2013 It started as an impulsive ... Halloween is a popular time for people to use colored contact lenses to enhance their costumes. From ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical ...

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus ... Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without ...

  12. Correlation between thromboelastography and traditional coagulation test parameters in hospitalized dogs

    Directory of Open Access Journals (Sweden)

    Rubanick JV

    2017-02-01

    Full Text Available Jean V Rubanick, Medora B Pashmakova, Micah A Bishop, James W Barr Department of Veterinary Small Animal Clinical Sciences, Texas A&M University, College Station, TX, USA Abstract: A hospital-based, prospective cross-sectional study was used to compare kaolin-activated thromboelastography (TEG parameters with traditional coagulation tests in 29 hospitalized dogs. Cases were included if the attending clinician requested coagulation testing. Blood was obtained from each dog and coagulation (prothrombin time, partial thromboplastin time, antithrombin activity, d-dimer concentration, and fibrinogen concentration and TEG analyses were performed. Hematocrit (Hct was also measured. Traditional coagulation results were evaluated for correlation with those from kaolin-activated TEG. Spearman’s correlation was used to calculate correlation coefficients. Fibrinogen was positively correlated with maximum amplitude (Pearson r=0.72, P<0.001 and global clot strength (Pearson r=0.72, P<0.001. There was no correlation between any of the remaining coagulation variables, TEG parameters, or Hct. Results of kaolin-activated TEG and traditional coagulation tests are not interchangeable means of monitoring coagulation derangements in this intensive care unit patient population. Determination of a true outcome measure is necessary to establish TEG’s clinical relevance to veterinary medicine. Keywords: TEG, thromboelastography, coagulation, hemostasis

  13. Inherited coagulation factor VII and X deficiencies associated with severe bleeding diathesis: Molecular genetics and pathophysiology

    NARCIS (Netherlands)

    Borensztajn, K.; Spek, C. A.

    2005-01-01

    The rare inherited coagulation disorders are a fascinating group of diseases that have provided us with important insights into the structure and functions of their respective deficient proteins. Factor (F)VII deficiency is the commonest of these inherited disorders of coagulation, whereas FX

  14. Plasma concentrations of blood coagulation factor VII measured by immunochemical and amidolytic methods

    DEFF Research Database (Denmark)

    Bladbjerg, E-M; Gram, J; Jespersen, J

    2000-01-01

    Ever since the coagulant activity of blood coagulation factor VII (FVII:C) was identified as a risk indicator of cardiac death, a large number of studies have measured FVII protein concentrations in plasma. FVII protein concentrations are either measured immunologically with an ELISA method (FVII...

  15. Identification of QTL on chromosome 18 associated with non-coagulating milk in Swedish Red cows

    NARCIS (Netherlands)

    Duchemin, Sandrine I.; Glantz, Maria; Koning, De Dirk Jan; Paulsson, Marie; Fikse, Willem F.

    2016-01-01

    Non-coagulating (NC) milk, defined as milk not coagulating within 40 min after rennet-addition, can have a negative influence on cheese production. Its prevalence is estimated at 18% in the Swedish Red (SR) cow population. Our study aimed at identifying genomic regions and causal variants

  16. Arsenic removal by coagulation using ferric chloride and chitosan from water

    Directory of Open Access Journals (Sweden)

    Farid Hesami

    2013-01-01

    Conclusions: Chitosan as natural coagulant aid improved arsenic removal efficiency by coagulation process using FeCl 3 . This method can be used for regions with drinking water contaminated with initial arsenic concentration less than 1 000 μg/l.

  17. The immediate and late effects of thyroid hormone (triiodothyronine) on murine coagulation gene transcription

    NARCIS (Netherlands)

    Salloum-Asfar, Salam; Boelen, Anita; Reitsma, Pieter H.; van Vlijmen, Bart J. M.

    2015-01-01

    Thyroid dysfunction is associated with changes in coagulation. The aim of our study was to gain more insight into the role of thyroid hormone in coagulation control. C57Black/6J mice received a low-iodine diet and drinking water supplemented with perchlorate to suppress endogenous triiodothyronine

  18. A review of studies of the activation of the blood coagulation mechanism in chimpanzees (Pan troglodytes)

    NARCIS (Netherlands)

    ten Cate, H.; Schenk, B. E.; Biemond, B. J.; Levi, M. [=Marcel M.; van der Poll, T.; Buller, H. R.; ten Cate, J. W.

    1994-01-01

    This paper reviews our recent studies of blood coagulation activation in the chimpanzee which were carried out employing sensitive immunoassays that measure activation markers of blood coagulation in plasma. Infused factor VIIa activated both factors IX and X in vivo; this reaction depended on the

  19. Coagulation competence and fluid recruitment after moderate blood loss in young men

    DEFF Research Database (Denmark)

    Zaar, Morten; Mørkeberg, Jakob; Pott, Frank C

    2014-01-01

    The coagulation system is activated by a reduction of the central blood volume during orthostatic stress and lower body negative pressure suggesting that also a blood loss enhances coagulation. During bleeding, however, the central blood volume is supported by fluid recruitment to the circulation...

  20. Chitosan as coagulant on cyanobacteria in lake restoration management may cause rapid cell lysis

    NARCIS (Netherlands)

    Nunes Teixeira Mucci, Maira; Noyma, Natalia Pessoa; Magalhães, de Leonardo; Miranda, Marcela; Oosterhout, van Frank; Guedes, Iamê Alves; Huszar, Vera L.M.; Marinho, Marcelo Manzi; Lürling, Miquel

    2017-01-01

    Combining coagulant and ballast to remove cyanobacteria from the water column is a promising restoration technique to mitigate cyanobacterial nuisance in surface waters. The organic, biodegradable polymer chitosan has been promoted as a coagulant and is viewed as non-toxic. In this study, we show

  1. Chitosan as coagulant on cyanobacteria in lake restoration management may cause rapid cell lysis

    NARCIS (Netherlands)

    Mucci, Maira; Noyma, Natalia Pessoa; de Magalhaes, Leonardo; Miranda, Marcela; van Oosterhout, Frank; Guedes, Iame Alves; Huszar, Vera L. M.; Marinho, Marcelo Manzi; Lürling, Miquel

    2017-01-01

    Combining coagulant and ballast to remove cyanobacteria from the water column is a promising restoration technique to mitigate cyanobacterial nuisance in surface waters. The organic, biodegradable polymer chitosan has been promoted as a coagulant and is viewed as non-toxic. In this study, we show

  2. Application of Moringa Oleifera Seed Powder For Iron (III Coagulation on Local Water Resources

    Directory of Open Access Journals (Sweden)

    Fadillah Utami Prasetyaningtyas

    2013-07-01

    Full Text Available This research aims to know the effect of the use of powder moringa seed to coagulant mass and coagulation process, and its effectiveness to increase the quality of pure water. This research uses factorial research design and statistic test MANOVA. To analyse water quality, the researcher uses Fe parameter.  A graphic of coagulant mass and time for each parameter is used to analyse the data. Based on the research result, the uses of moringa seed as coagulant in each 300 mL mineral water gives a possitives result to the river water sample using 100 mg coagulant mass and sedimentations time for 60 minutes, well water sample using 500 mg coagulant mass and sedimentations time for 60 minutes, tap water sample using 300 mg  coagulant mass and sedimentations time for 90 minutes. The effective coagulant that increase the water quality on well water is 98,32% of moringa seed powder, on river water is 96,64%  and for tap water is 25,62%.

  3. PILOT PLANT STUDY ON NATURAL WATER COAGULANTS AS COAGULAN AIDS FOR WATER SUPPLY

    Directory of Open Access Journals (Sweden)

    B BINA

    2001-06-01

    Full Text Available Introduction: Natural plant coagulants have an important role to play in provision of portable water to rural communities in the developing world. The plant material that their coagulation properties have been confirmed in previous lab scale studies and can be found widely in Iran was selected as coagulant aids. Pilot plant study was done to evaluate the efficiency of natural material such as Starch/Gum Tragacanth, Fenugreek and Yeast as coagulant aids in conjunction with comercial alum. Methods: The pilot was placed in Isfahan Water Treatment Plant (IWTP and efficiency of these materials in removal of turbidity from raw water enters the IWTP was evaluated. The results indicated while these materials were used as coagulant aids in concentration of 1-5 mg/l conjunction with alum are able to reduced the turbidity and final residuals turbidity meets the standards limits. Results: The coagulation efficiency of these material were found to be effected by certain physico-chemical factors, namely, concentration of suspended solids, divalent cation metal and time of agitation. The relative importance of these variable was evaluated. The results of COD test proved that the natural coagulant aids in the optimum doses produce no any significant organic residual. Discussion: Economical considerations showed that using of these material as coagulant aids can cause reduction in alum consumption and in some cases are more econmical than synthetic polyelectrolyte.

  4. A new inorganic-organic composite coagulant, consisting of polyferric sulphate (PFS) and polyacrylamide (PAA).

    Science.gov (United States)

    Moussas, P A; Zouboulis, A I

    2009-08-01

    Currently, research is focused on the synthesis of new composite coagulants, which are constituted of both inorganic and organic materials. In this paper, the development of relevant reagents was investigated, by combining the inorganic pre-polymerised iron-based coagulant Polyferric Sulphate (PFS) with an organic, non-ionic polymer (Polyacrylamide, PAA) under different PAA/Fe (mg/l) and OH/Fe molar ratios. Moreover, the new reagents were characterised in terms of typical properties, stability and morphological analysis (XRD, FTIR, SEM). Their coagulation performance, when treating low or high turbid kaolin-humic acid suspensions, was also investigated, whereas the applied coagulation mechanisms were discussed by using the Photometric Dispersion Analysis (PDA) analysis. The results show that the new coagulation reagents present improved properties, including increased effective polymer species concentration, and they exhibit very good stability. The respective tests using PDA confirmed that the predominant coagulation mechanism of PFS-PAA is the bridge formation mechanism. Coagulation experiments in low or high turbid kaolin-humic acid suspensions reveal that the novel composite reagent PFS-PAA exhibits better coagulation performance, when compared with simple PFS, in terms of zeta-potential reduction, turbidity and organic matter removal and residual iron concentration.

  5. Potential of Hibiscus Sabdariffa and Jatropha Curcas as Natural Coagulants in the Treatment of Pharmaceutical Wastewater

    Directory of Open Access Journals (Sweden)

    Sibartie Sheena

    2018-01-01

    Full Text Available Pharmaceutical wastewater is one of the most difficult wastewater to treat due to the presence of pharmaceutical compounds resulting in high concentration of organic matter, high turbidity and Chemical Oxygen Demand (COD. Chemical-based coagulation is a common method used to treat wastewater. However, the issue that has been raised with the use of chemical coagulants is their presence in water after treatment that can cause risks to the human health such as Alzheimer and cancer. Natural coagulants can be used as a safe alternative to these chemicals instead. Therefore, the objective of this experiment was to study the effect of H. Sabdariffa and J. Curcas as natural coagulants, separately and as a combination, on the treatment of pharmaceutical wastewater. Jar test experiment were carried out where beakers of 0.5L wastewater were mixed with the coagulants. The pH of the wastewater was varied from 2 to 12 while the coagulant dosage was varied from 40 to 200 mg/L. It was found that H. Sabdariffa works best at pH 4 and at a coagulant dosage of 190 mg/L with a highest turbidity removal of 35.8% and a decrease of COD by 29%. J. Curcas was found to perform best at pH 3 and with a coagulant dosage of 200 mg/L with a highest turbidity removal of 51% and a decrease of COD by 32%. When J. Curcas and H. Sabdariffa were used in combination, the optimum composition was found to be 80% J. Curcas and 20% H. Sabdariffa by weight with a maximum turbidity removal of 46.8% and a decrease in COD by 46%. In comparison between the two natural coagulants, J. Curcas is found to be a better and more suited coagulative agent for the treatment of pharmaceutical wastewater. The same experiment was carried with alum at pH 6 and coagulant dosage of 750 mg/L and a turbidity removal of 48% and a decrease in COD by 38% were recorded. In comparison with alum, J. Curcas was a better coagulant in treating the pharmaceutical wastewater. This shows that natural coagulants can be

  6. Lettuce contact allergy.

    Science.gov (United States)

    Paulsen, Evy; Andersen, Klaus E

    2016-02-01

    Lettuce (Lactuca sativa L.) and its varieties are important vegetable crops worldwide. They are also well-known, rarely reported, causes of contact allergy. As lettuce allergens and extracts are not commercially available, the allergy may be underdiagnosed. The aims of this article are to present new data on lettuce contact allergy and review the literature. Lettuce is weakly allergenic, and occupational cases are mainly reported. Using aimed patch testing in Compositae-allergic patients, two recent Danish studies showed prevalence rates of positive lettuce reactions of 11% and 22%. The majority of cases are non-occupational, and may partly be caused by cross-reactivity. The sesquiterpene lactone mix seems to be a poor screening agent for lettuce contact allergy, as the prevalence of positive reactions is significantly higher in non-occupationally sensitized patients. Because of the easy degradability of lettuce allergens, it is recommended to patch test with freshly cut lettuce stem and supplement this with Compositae mix. As contact urticaria and protein contact dermatitis may present as dermatitis, it is important to perform prick-to-prick tests, and possibly scratch patch tests as well. Any person who is occupationally exposed to lettuce for longer periods, especially atopics, amateur gardeners, and persons keeping lettuce-eating pets, is potentially at risk of developing lettuce contact allergy. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Diffusion mediated coagulation and fragmentation based study of domain formation in lipid bilayer membrane

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Laxminarsimha V., E-mail: laxman@iitk.ac.in [Mechanics and Applied Mathematics Group, Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur 208016 (India); Roy, Subhradeep [Department of Biomedical Engineering and Mechanics (MC 0219), Virginia Tech, 495 Old Turner Street, Blacksburg, VA 24061 (United States); Das, Sovan Lal [Mechanics and Applied Mathematics Group, Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur 208016 (India)

    2017-01-15

    We estimate the equilibrium size distribution of cholesterol rich micro-domains on a lipid bilayer by solving Smoluchowski equation for coagulation and fragmentation. Towards this aim, we first derive the coagulation kernels based on the diffusion behaviour of domains moving in a two dimensional membrane sheet, as this represents the reality better. We incorporate three different diffusion scenarios of domain diffusion into our coagulation kernel. Subsequently, we investigate the influence of the parameters in our model on the coagulation and fragmentation behaviour. The observed behaviours of the coagulation and fragmentation kernels are also manifested in the equilibrium domain size distribution and its first moment. Finally, considering the liquid domains diffusing in a supported lipid bilayer, we fit the equilibrium domain size distribution to a benchmark solution.

  8. Effect of THI on milk coagulation properties of Holstein-Friesian dairy cattle

    Directory of Open Access Journals (Sweden)

    Simone Beux

    Full Text Available ABSTRACT The objective of this study was to evaluate the effect of temperature-humidity index (THI on the milk coagulation properties of Holstein-Friesian dairy cattle from northeast part of Italy. A total of 592 individual milk samples from six dairy herds were evaluated. The milk coagulation properties traits analysed were milk rennet coagulation time and curd firmness, as well as the fat, protein, and casein contents, pH, milk aptitude to coagulate (IAC, and the somatic cell count. The THI was determined during the periods of sample collection. The THI results showed that values of up to 75 did not significantly change the IAC values; however, when the THI values were above 75, the IAC decreased significantly. The control of THI can be used to guarantee appropriate milk coagulation properties.

  9. Development of a magnetic coagulant based on Moringa oleifera seed extract for water treatment.

    Science.gov (United States)

    Santos, Tássia R T; Silva, Marcela F; Nishi, Leticia; Vieira, Angélica M S; Fagundes-Klen, Márcia R; Andrade, Murilo B; Vieira, Marcelo F; Bergamasco, Rosângela

    2016-04-01

    In this work, to evaluate the effectiveness of the coagulation/flocculation using a natural coagulant, using Moringa oleifera Lam functionalized with magnetic iron oxide nanoparticles, producing flakes that are attracted by an external magnetic field, thereby allowing a fast settling and separation of the clarified liquid, is proposed. The removal efficiency of the parameters, apparent color, turbidity, and compounds with UV254nm absorption, was evaluated. The magnetic functionalized M. oleifera Lam coagulant could effectively remove 90 % of turbidity, 85 % of apparent color, and 50 % for the compounds with absorption at UV254nm, in surface waters under the influence of an external magnetic field within 30 min. It was found that the coagulation/flocculation treatment using magnetic functionalized M. oleifera Lam coagulant was able to reduce the values of the physico-chemical parameters evaluated with reduced settling time.

  10. Patients with multiple contact allergies

    DEFF Research Database (Denmark)

    Carlsen, Berit Christina; Andersen, Klaus Ejner; Menné, Torkil

    2008-01-01

    Patients with multiple contact allergies, also referred to as polysensitized, are more frequent than predicted from prevalence of single sensitivities. The understanding of why some people develop multiple contact allergies, and characterization of patients with multiple contact allergies...... of developing multiple contact allergies. Evidence of allergen clusters among polysensitized individuals is also reviewed. The literature supports the idea that patients with multiple contact allergies constitute a special entity within the field of contact allergy. There is no generally accepted definition...... of patients with multiple contact allergies. We suggest that contact allergy to 3 or more allergens are defined as multiple contact allergies....

  11. Evaluating the Efficiency of Tragacanth Coagulant Aid in Removing Colloidal Materials and Suspended Solids Creating Turbidity from Karun River Water

    OpenAIRE

    Majid Farhadi; Afshin Takdastan; Roghayeh Baghbany

    2016-01-01

    Introduction: Colloidal materials and suspended solids cause turbidity in water. To remove turbidity, clarification method is used that includes processes of coagulation, flocculation, and sedimentation. Due to the long duration of coagulation process, coagulant aids are applied. Despite the favorable efficiency of synthetic polyelectrolytes as a coagulant aid, due to their harmful effects on human health, in this process, natural organic polymers are used instead. Materials and Methods: I...

  12. Evaluation of Impact of Coagulant Type on Operation Parameters in Direct Filtration

    Directory of Open Access Journals (Sweden)

    Ali Torabian

    2007-06-01

    Full Text Available Numerous advantages have been reported on PAC (poly aluminum chloride used as a coagulant over other coagulants such as alum and ferric chloride used in conventional water treatment process with medium and high turbidity levels. These include lower amounts of PACL required specially in removing turbidity, larger floc grain formation, reduced floc sedimentation time, lower sludge production, and relaxation of the need for pH adjustment by lime, among others. The present study aims to evaluate the effects of different coagulants such as ferric chloride and PACL on direct filtration and to identify the most effective material based on both turbidity and particle removal efficiencies. A perfectly experimental pilot system, including raw water preparation, coagulation, flocculation, distribution measurement, and filtration units, was designed and used. Raw water turbidity level in the experimental pilot was below 10 NTU. The effects of various parameters such as coagulant type, filtration rate, and coagulant dosage on the performance of the filter were investigated. The results obtained from several filtration cycles under different conditions indicated that average effluent turbidity level, effluent particle numbers, effluent turbidity variation graph, and effluent particle graph were lower throughout the filtration cycle when PACL was used compared to when ferric chloride was used as the coagulant. Increasing filtration rate led to increased turbidity and particle number. Addition of 2 mg/l of PACL (poor coagulation and flocculation scenario was compared with addition of 5 mg/l of ferric chloride (strong coagulation and flocculation scenario. The results indicated that higher average values of turbidity removal but lower turbidity and particle removal efficiencies obtained in the case of the poor coagulation and flocculation scenario.

  13. Tissue Factor Coagulant Activity is Regulated by the Plasma Membrane Microenvironment.

    Science.gov (United States)

    Yu, Yuanjie; Böing, Anita N; Hau, Chi M; Hajji, Najat; Ruf, Wolfram; Sturk, Auguste; Nieuwland, Rienk

    2018-06-01

     Tissue factor (TF) can be present in a non-coagulant and coagulant form. Whether the coagulant activity is affected by the plasma membrane microenvironment is unexplored.  This article studies the presence and coagulant activity of human TF in plasma membrane micro-domains.  Plasma membranes were isolated from human MIA PaCa2 cells, MDA-MB-231 cells and human vascular smooth muscle cells by Percoll gradient ultracentrifugation after cell disruption. Plasma membranes were fractionated by OptiPrep gradient ultracentrifugation, and the presence of TF, flotillin, caveolin, clathrin, protein disulphide isomerase (PDI), TF pathway inhibitor (TFPI) and phosphatidylserine (PS) were determined.  Plasma membranes contain two detergent-resistant membrane (DRM) compartments differing in density and biochemical composition. High-density DRMs (DRM-H) have a density ( ρ ) of 1.15 to 1.20 g/mL and contain clathrin, whereas low-density DRMs (DRM-L) have a density between 1.09 and 1.13 g/mL and do not contain clathrin. Both DRMs contain TF, flotillin and caveolin. PDI is detectable in DRM-H, TFPI is not detectable in either DMR-H or DRM-L and PS is detectable in DRM-L. The DRM-H-associated TF (> 95% of the TF antigen) lacks detectable coagulant activity, whereas the DRM-L-associated TF triggers coagulation. This coagulant activity is inhibited by lactadherin and thus PS-dependent, but seemed insensitive to 16F16, an inhibitor of PDI.  Non-coagulant and coagulant TF are present within different types of DRMs in the plasma membrane, and the composition of these DRMs may affect the TF coagulant activity. Schattauer GmbH Stuttgart.

  14. Haematology and coagulation profiles in cats with congenital portosystemic shunts.

    Science.gov (United States)

    Tzounos, Caitlin E; Tivers, Michael S; Adamantos, Sophie E; English, Kate; Rees, Alan L; Lipscomb, Vicky J

    2017-12-01

    Objectives The objectives of this study were, first, to report the haematological parameters and coagulation times for cats with a congenital portosystemic shunt (CPSS) and the influence of surgical shunt attenuation on these parameters; and, second, to identify any association between prolongation in coagulation profiles and incidence of perioperative haemorrhage. Methods This was a retrospective clinical study using client-owned cats with a CPSS. Signalment, shunt type (extra- or intrahepatic), degree of shunt attenuation (complete or partial), haematological parameters, prothrombin time (PT) and activated partial thromboplastin time (aPTT) test results, and occurrence of any perioperative clinical bleeding complications were recorded for cats undergoing surgical treatment of a CPSS at the Royal Veterinary College, UK, between 1994 and 2011. Results Forty-two cats were included. Thirty-six (85.7%) had an extrahepatic CPSS and six (14.3%) had an intrahepatic CPSS. Preoperatively, mean cell volume (MCV) and mean cell haemoglobin (MCH) were below the reference interval (RI) in 32 (76.2%) and 31 (73.8%) cats, respectively. Red blood cell count and mean cell haemoglobin concentration (MCHC) were above the RI in 10 (23.8%) and eight (19.1%) cats, respectively. Postoperatively, there were significant increases in haematocrit ( P = 0.044), MCV ( P = 0.008) and MCH ( P = 0.002). Despite the significant increase in MCV postoperatively, the median MCV postoperatively was below the RI, indicating persistence of microcytosis. Preoperatively, PT was above the upper RI in 14 cats (87.5%), and aPTT was above the upper RI in 11 cats (68.8%). No cat demonstrated a perioperative clinical bleeding complication. Conclusions and relevance Cats with a CPSS are likely to present with a microcytosis, but rarely present with anaemia, leukocytosis or thrombocytopenia. Surgical attenuation of the CPSS results in a significant increase in the HCT and MCV. Coagulation profiles in cats with a

  15. Argon plasma coagulation for rectal bleeding after prostate brachytherapy

    International Nuclear Information System (INIS)

    Smith, Stephen; Wallner, Kent; Dominitz, Jason A.; Han, Ben; True, Lawrence; Sutlief, Steven; Billingsley, Kevin

    2001-01-01

    Purpose: To better define the efficacy and safety of argon plasma coagulation (APC), specifically for brachytherapy-related proctitis, we reviewed the clinical course of 7 patients treated for persistent rectal bleeding. Approximately 2-10% of prostate cancer patients treated with 125 I or 103 Pd brachytherapy will develop radiation proctitis. The optimum treatment for patients with persistent bleeding is unclear from the paucity of available data. Prior reports lack specific dosimetric information, and patients with widely divergent forms of radiation were grouped together in the analyses. Methods and Materials: Seven patients were treated with APC at the Veterans Affairs Puget Sound Health Care System and the University of Washington from 1997 to 1999 for persistent rectal bleeding due to prostate brachytherapy-related proctitis. Four patients received supplemental external beam radiation, delivered by a four-field technique. A single gastroenterologist at the Veterans Affairs Puget Sound Health Care System treated 6 of the 7 patients. If the degree of proctitis was limited, all sites of active bleeding were coagulated in symptomatic patients. An argon plasma coagulator electrosurgical system was used to administer treatments every 4-8 weeks as needed. The argon gas flow was set at 1.6 L/min, with an electrical power setting of 40-45 W. Results: The rectal V100 (the total rectal volume, including the lumen, receiving the prescription dose or greater) for the 7 patients ranged from 0.13 to 4.61 cc. Rectal bleeding was first noticed 3-18 months after implantation. APC (range 1-3 sessions) was performed 9-22 months after implantation. Five patients had complete resolution of their bleeding, usually within days of completing APC. Two patients had only partial relief from bleeding, but declined additional APC therapy. No patient developed clinically evident progressive rectal wall abnormalities after APC, (post-APC follow-up range 4-13 months). Conclusions: Most

  16. Conservative systems with ports on contact manifolds

    NARCIS (Netherlands)

    Eberard, D.; Maschke, B.M.; van der Schaft, Arjan; Piztek, P.

    In this paper we propose an extension of port Hamiltonian systems, called conservative systems with ports, which encompass systems arising from the Irreversible Thermodynamics. Firstly we lift a port Hamiltonian system from its state space manifold to the thermodynamic phase space to a contact

  17. Identification of coagulation gene 3′UTR variants that are potentially regulated by microRNAs

    NARCIS (Netherlands)

    Vossen, Carla Y.; van Hylckama Vlieg, Astrid; Teruel-Montoya, Raúl; Salloum-Asfar, Salam; de Haan, Hugoline G.; Corral, Javier; Reitsma, Pieter H.; Koeleman, Bobby P.C.; Martínez, Constantino

    2017-01-01

    MicroRNAs have been recognized as critical regulators of gene expression and might affect the risk of venous thrombosis. We aimed to identify 3′ untranslated region (UTR) variants in coagulation genes that influence coagulation factor levels and venous thrombosis risk. The 3′UTR of coagulation genes

  18. Applications of Natural Coagulants to Treat Wastewater − A Review

    Directory of Open Access Journals (Sweden)

    Kumar Vicky

    2017-01-01

    Full Text Available The natural water falls from the mountain is merging into the oceans. This water is preserved by humans that are consumed for agriculture, industrial, and municipal use. This water become wastewater after different usage, and finally, completes the hydrological cycle. The water becomes wastewater due to population growth, urbanization, industrialization, sewage from household, institutions, hospitals, industries and etc. Wastewater can be destructive for the public because it contains a variety of organic and inorganic substances, biological substances, toxic inorganic compounds and the presence of toxic materials. The coagulant chemicals and its associated products are resourceful but these may change the characteristics of water in terms of physical and chemical characteristics, this make matters worse in the disposal of sludge. An option of natural polymer can be used in water and wastewater in this review. The natural polymers are most efficient that provide several benefits such as; prolific, exempt from physical and chemical changes from the treated water.

  19. Purification and Autoactivation Method for Recombinant Coagulation Factor VII.

    Science.gov (United States)

    Granovski, Vladimir; Freitas, Marcela C C; Abreu-Neto, Mario Soares; Covas, Dimas T

    2018-01-01

    Recombinant coagulation factor VII is a very important and complex protein employed for treatment of hemophiliac patients (hemophilia A/B) who develop inhibitors antibodies to conventional treatments (FVIII and FIX). The rFVII is a glycosylated molecule and circulates in plasma as zymogen of 50 kDa. When activated the molecule is cleaved to 20-30 kDa and has a half-life of about 3 h, needing to be processed fast and efficiently until freeze-drying. Here, we describe a very simple and fast purification sequence for rFVII using affinity FVII Select resin and a dialysis system that can be easily scaled up.

  20. Scaling of cluster growth for coagulating active particles

    Science.gov (United States)

    Cremer, Peet; Löwen, Hartmut

    2014-02-01

    Cluster growth in a coagulating system of active particles (such as microswimmers in a solvent) is studied by theory and simulation. In contrast to passive systems, the net velocity of a cluster can have various scalings dependent on the propulsion mechanism and alignment of individual particles. Additionally, the persistence length of the cluster trajectory typically increases with size. As a consequence, a growing cluster collects neighboring particles in a very efficient way and thus amplifies its growth further. This results in unusual large growth exponents for the scaling of the cluster size with time and, for certain conditions, even leads to "explosive" cluster growth where the cluster becomes macroscopic in a finite amount of time.

  1. Particle removal by coagulation and settling from a waste plume

    International Nuclear Information System (INIS)

    Hunt, J.R.

    1990-01-01

    Oceanic and coastal waters have long been used for disposal of human wastes, such as treated sewage, sewage sludge, dredged sediments from harbors, and more recently, drilling fluids from offshore oil exploration and deep-ocean bottom sediments that are resuspended by mining activities. These wastes contain pollutants mainly in the particulate fraction. Because most organic matter is particulate matter, toxic metals are either present as sulfide precipitates or adsorbed onto other particles, and suspended particles themselves are viewed as pollutants if an increase in turbidity is apparent. Thus, to analyze waste-disposal practices, an accurate prediction is needed for the fate of waste particles. This paper demonstrates how particle coagulation can be incorporated into models for predicting the fate of particulate wastes that are discharged into oceanic waters

  2. Analysis of ultrasonic techniques for monitoring milk coagulation during cheesemaking

    International Nuclear Information System (INIS)

    Budelli, E; Lema, P; Pérez, N; Negreira, C

    2012-01-01

    Experimental determination of time of flight and attenuation has been proposed in the literature as alternatives to monitoring the evolution of milk coagulation during cheese manufacturing. However, only laboratory scale procedures have been described. In this work, the use of ultrasonic time of flight and attenuation to determine cutting time and its feasibility to be applied at industrial scale were analyzed. Limitations to implement these techniques at industrial scale are shown experimentally. The main limitation of the use of time of flight is its strong dependence with temperature. Attenuation monitoring is affected by a thin layer of milk skin covering the transducer, which modifies the signal in a non-repetitive way. The results of this work can be used to develop alternative ultrasonic systems suitable for application in the dairy industry.

  3. The effects of transport by car on coagulation tests.

    Science.gov (United States)

    Ergin, Merve; Erdogan, Serpil; Akturk, Onur; Erel, Ozcan

    2017-10-26

    This research investigated the effects of the transport of blood samples between centers/laboratories by car on coagulation tests. Five tubes of blood samples were taken from 20 healthy volunteers. The samples consisted of a baseline (control) group, centrifuged and noncentrifuged transported samples; centrifuged and noncentrifuged untransported samples. The groups of centrifuged and noncentrifuged samples were transported by car for 2 h. The centrifuged and noncentrifuged untransported samples were incubated in the laboratory until the transported samples arrived. Prothrombin time (PT) and activated partial thromboplastin time (APTT) tests were conducted for all samples. Significant differences between the baseline group and the centrifuged and noncentrifuged transported samples and the noncentrifuged untransported samples were found for APTT levels (pcar.

  4. Intestinal volvulus with coagulative hepatic necrosis in a chicken.

    Science.gov (United States)

    Haridy, Mohie; Goryo, Masanobu; Sasaki, Jun; Okada, Kosuke

    2010-04-01

    A 7-week-old SPF chicken inoculated at 4 weeks of age with chicken anemia virus was puffed up depressed and had ruffled feathers and a good body condition. Intestinal volvulus involving the jejunum and part of the duodenum forming two loops with one knob was observed. Microscopically, venous infarction of the obstructed loops, periportal and sublobular multifocal coagulative hepatic necrosis and granulomatous inflammation of the cecal tonsils were observed. Gram staining revealed no bacteria in hepatic tissue; however, gram-positive bacilli were detected in the necrotic debris in the intestinal lumen. Immunosuppression might have predisposed the chicken to intestinal and cecal tonsil infection that then progressed to volvulus. Loss of the mucosal barrier in infarction might allow bacterial toxins and vasoactive factors to escape into the systemic circulation (toxemia) and be responsible for the hepatic necrosis.

  5. Quality standards for sample collection in coagulation testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Lima-Oliveira, Gabriel; Guidi, Gian Cesare; Favaloro, Emmanuel J

    2012-09-01

    Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Natural coagulation inhibitors and active protein c resistance in preeclampsia

    Directory of Open Access Journals (Sweden)

    Cengiz Demir

    2010-01-01

    Full Text Available INTRODUCTION: The etiology of preeclampsia is not fully established. A few studies have shown a relationship between natural coagulation inhibitors and preeclampsia. OBJECTIVES: The purpose of this study was to investigate the status of natural coagulation inhibitors and active protein C resistance (APC-R in preeclampsia. PATIENTS AND METHODS: We studied 70 women with preeclampsia recruited consecutively and 70 healthy pregnant and 70 nonpregnant women as controls. Plasma protein C (PC, free protein S (fPS, antithrombin III (ATIII and APC-R were evaluated. RESULTS: ATIII values were found to be significantly lower in preeclamptic patients than in the control groups (p< 0.001. Nevertheless, there was no significant difference between the healthy pregnant and nonpregnant women groups (p=0.141. The fPS values of the preeclamptic and healthy pregnant groups were lower than that of the nonpregnant group (p< 0.001, and the fPS value of the preeclamptic pregnant women was lower than that of healthy pregnant women (p<0.001. The PC value of the preeclamptic pregnant women was lower than that of the control groups (p< 0.001. The PC value of the healthy pregnant women was lower than that of the nonpregnant women (p< 0.001. The mean APC activity values were lower in the preeclamptic patients than that of the control groups (p< 0.001, p< 0.001. The APC-R positivity rates of the preeclamptic groups were higher than that of the control groups (p<0.001. CONCLUSIONS: This study demonstrated that ATIII, fPS, PC values and APC resistance were lower and APC-R positivity was higher in preeclamptic women than in normal pregnant and nonpregnant women.

  7. Coagulation processes of kaolinite and montmorillonite in calm, saline water

    Science.gov (United States)

    Zhang, Jin-Feng; Zhang, Qing-He; Maa, Jerome P.-Y.

    2018-03-01

    A three dimensional numerical model for simulating the coagulation processes of colloids has been performed by monitoring the time evolution of particle number concentration, the size distribution of aggregates, the averaged settling velocity, the collision frequency, and the collision efficiency in quiescent water with selected salinities. This model directly simulates all interaction forces between particles based on the lattice Boltzmann method (LBM) and the extended Derjaguin-Landau-Verwey-Overbeek (XDLVO) theory, and thus, can reveal the collision and coagulation processes of colloidal suspensions. Although using perfect spherical particles in the modeling, the results were compared with those for kaolinite and montmorillonite suspensions to demonstrate the capability of simulating the responses of these particles with highly irregular shape. The averaged settling velocity of kaolinite aggregates in quiescent saline water reached a maximum of 0.16 mm/s when the salinity increasing to about 3, and then, exhibited little dependence on salinity thereafter. Model simulations results (by choosing specific values that represent kaolinite's characteristics) indicate a similar trend: rapid decrease of the particle number concentration (i.e., rapidly flocculated, and thus, settling velocity also increases rapidly) when salinity increases from 0 to 2, and then, only increased slightly when salinity was further increased from 5 to 20. The collision frequency for kaolinite only decreases slightly with increasing salinity because that the fluid density and viscosity increase slightly in sea water. It suggests that the collision efficiency for kaolinite rises rapidly at low salinities and levels off at high salinity. For montmorillonite, the settling velocity of aggregates in quiescent saline water continuedly increases to 0.022 mm/s over the whole salinity range 0-20, and the collision efficiency for montmorillonite rises with increasing salinities.

  8. ON THE COAGULATION AND SIZE DISTRIBUTION OF PRESSURE CONFINED CORES

    International Nuclear Information System (INIS)

    Huang Xu; Zhou Tingtao; Lin, D. N. C.

    2013-01-01

    Observations of the Pipe Nebula have led to the discovery of dense starless cores. The mass of most cores is too small for their self-gravity to hold them together. Instead, they are thought to be pressure confined. The observed dense cores' mass function (CMF) matches well with the initial mass function of stars in young clusters. Similar CMFs are observed in other star forming regions such as the Aquila Nebula, albeit with some dispersion. The shape of these CMF provides important clues to the competing physical processes which lead to star formation and its feedback on the interstellar media. In this paper, we investigate the dynamical origin of the mass function of starless cores which are confined by a warm, less dense medium. In order to follow the evolution of the CMF, we construct a numerical method to consider the coagulation between the cold cores and their ablation due to Kelvin-Helmholtz instability induced by their relative motion through the warm medium. We are able to reproduce the observed CMF among the starless cores in the Pipe Nebula. Our results indicate that in environment similar to the Pipe Nebula: (1) before the onset of their gravitational collapse, the mass distribution of the progenitor cores is similar to that of the young stars, (2) the observed CMF is a robust consequence of dynamical equilibrium between the coagulation and ablation of cores, and (3) a break in the slope of the CMF is due to the enhancement of collisional cross section and suppression of ablation for cores with masses larger than the cores' Bonnor-Ebert mass.

  9. Benign intracranial hypertension associated to blood coagulation derangements

    Directory of Open Access Journals (Sweden)

    Niglio Alferio

    2006-12-01

    Full Text Available Abstract Background Benign Intracranial Hypertension (BIH may be caused, at least in part, by intracranial sinus thrombosis. Thrombosis is normally due to derangements in blood coagulation cascade which may predispose to abnormal clotting activation or deficiency in natural inhibitors' control. The aim of the study is to examine the strength of the association between risk factors for thrombosis and BIH. Patients and methods The incidence of prothrombotic abnormalities among a randomly investigated cohort of 17 patients with BIH, was compared with 51 healthy subjects matched for sex, age, body mass index, height and social background. Results The number of subjects with protein C deficiency was significantly higher in patients than in controls (3 vs 1, p Increased plasma levels of prothrombin fragment 1+2, fibrinopeptide A (FPA, and PAI-1 were demonstrated in patients group (5.7 ± 1.15 nM vs 0.45 ± 0.35 nM; 8.7 ± 2.5 ng/mL vs 2.2 ± 1.25 ng/mL; 45.7 ± 12.5 ng/mL vs 8.5 ± 6.7 ng/mL, respectively; p Discussion In agreement with other authors our data suggest a state of hypercoagulability in BIH associated with gene polymorphisms. Our findings also showed that mutations in cardiovascular genes significantly discriminate subjects with a BIH history. The association between coagulation and gene derangements, usually regarded to as cryptogenic, may suggest a possible pathogenetic mechanism in BIH. So, a prothrombotic tendency may exist that would, at least in part, explain some cases of BIH. Although based on a small population, these findings raise the exciting possibility of using these haemostatic factors as markers for selecting high-risk subjects in BIH disease.

  10. Rough Surface Contact

    Directory of Open Access Journals (Sweden)

    T Nguyen

    2017-06-01

    Full Text Available This paper studies the contact of general rough curved surfaces having nearly identical geometries, assuming the contact at each differential area obeys the model proposed by Greenwood and Williamson. In order to account for the most general gross geometry, principles of differential geometry of surface are applied. This method while requires more rigorous mathematical manipulations, the fact that it preserves the original surface geometries thus makes the modeling procedure much more intuitive. For subsequent use, differential geometry of axis-symmetric surface is considered instead of general surface (although this “general case” can be done as well in Chapter 3.1. The final formulas for contact area, load, and frictional torque are derived in Chapter 3.2.

  11. Acrylate Systemic Contact Dermatitis.

    Science.gov (United States)

    Sauder, Maxwell B; Pratt, Melanie D

    2015-01-01

    Acrylates, the 2012 American Contact Dermatitis Society allergen of the year, are found in a range of products including the absorbent materials within feminine hygiene pads. When fully polymerized, acrylates are nonimmunogenic; however, if not completely cured, the monomers can be potent allergens.A 28-year-old woman is presented, who had her teeth varnished with Isodan (Septodont, Saint-Maur-des-Fossés, France) containing HEMA (2-hydroxyethyl methacrylate) with no initial reaction. Approximately 1 month later, the patient developed a genital dermatitis secondary to her feminine hygiene pads. The initial reaction resolved, but 5 months later, the patient developed a systemic contact dermatitis after receiving a second varnishing.The patient was dramatically patch test positive to many acrylates. This case demonstrates a reaction to likely unpolymerized acrylates within a feminine hygiene pad, as well as broad cross-reactivity or cosensitivity to acrylates, and possibly a systemic contact dermatitis with systemic re-exposure to unpolymerized acrylates.

  12. Shoe allergic contact dermatitis.

    Science.gov (United States)

    Matthys, Erin; Zahir, Amir; Ehrlich, Alison

    2014-01-01

    Foot dermatitis is a widespread condition, affecting men and women of all ages. Because of the location, this condition may present as a debilitating problem to those who have it. Allergic contact dermatitis involving the feet is frequently due to shoes or socks. The allergens that cause shoe dermatitis can be found in any constituent of footwear, including rubber, adhesives, leather, dyes, metals, and medicaments. The goal of treatment is to identify and minimize contact with the offending allergen(s). The lack of product information released from shoe manufacturers and the continually changing trends in footwear present a challenge in treating this condition. The aim of this study is to review the current literature on allergic contact shoe dermatitis; clinical presentation, allergens, patch testing, and management will be discussed. PubMed and MEDLINE databases were used for the search, with a focus on literature updates from the last 15 years.

  13. ALLERGIC CONTACT DERMATITIS

    Directory of Open Access Journals (Sweden)

    Trisna Yuliharti Tersinanda

    2013-07-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE Allergic contact dermatitis is an immunologic reaction that tends to involve the surrounding skin and may even spread beyond affected sites. This skin disease is one of the more frequent, and costly dermatologic problems. Recent data from United Kingdom and United States suggest that the percentage of occupational contact dermatitis due to allergy may be much higher, thus raising the economic impact of occupational allergic contact dermatitis. There is not enough data about the epidemiology of allergic contact dermatitis in Indonesia, however based on research that include beautician in Denpasar, about 27,6 percent had side effect of cosmetics, which is 25,4 percent of it manifested as allergic contact dermatitis. Diagnosis of allergic contact dermatitis is based on anamnesis, physical examination, patch test, and this disease should be distinguished from other eczematous skin disease. The management is prevention of allergen exposure, symptomatic treatment, and physicochemical barrier /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin-top:0in; mso-para-margin-right:0in; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}

  14. Simple and rapid methods for purification and characterization of active coagulants from the seeds of Vigna unguiculata and Parkinsonia aculeata.

    Science.gov (United States)

    Marobhe, N J; Dalhammar, G; Gunaratna, K R

    2007-06-01

    The coagulating properties of aqueous crude extracts and purified proteins of Vigna unguiculata and Parkinsonia aculeata seeds, which are traditional water coagulants in rural areas of Tanzania, were studied. The coagulation activity assays were done using one millilitre (ml) of kaolin water samples. Coagulating proteins were purified in two-step ion exchange chromatography. The properties of coagulant protein were compared with Moringa oleifera. Coagulating components eluted by 0.6 M NaCl in both coagulants are cationic proteins that have the molecular mass of about 6 kDa, which is very similar to that of M. oleifera. The proteins of V. unguiculata and P. aculeata eluted by 0.3 M NaCl also harbour coagulation activity but proteins eluted with 0.6 M NaCl have higher activity. The dosage for coagulation using purified proteins of both coagulants is about 5 to 10 times lower than that of crude seed extracts. The optimum floc settling time of water treated by crude seed extracts and purified proteins ranged between two and two and half hours. Coagulating proteins of both coagulants eluted by 0.6 M NaCl are thermoresistant and retained coagulation activity of 87% to 92% after boiling for two hours at 80 degrees C and one hour at 95 degrees C. Thermotolerant proteins of V. unguiculata eluted by 0.6 M NaCl and P. aculeata have wider pH range of 5.5 to 8.5 for coagulation activity than those of M. oleifera proteins. The present investigation reveals the possibility of using purified natural coagulants for water treatment to produce safe drinking water.

  15. A natural coagulant protein from Moringa oleifera: isolation, characterization, and potential use for water treatment

    Science.gov (United States)

    Choudhary, Manisha; Neogi, Sudarsan

    2017-10-01

    In developing countries pond water is still widely used for drinking and household purposes, which develops higher turbidity during rainy seasons and requires a large amount of chemical coagulants, and this leads to high cost of treatment. To mitigate this, it is important to find an economical and natural coagulant to treat turbid water. The present study is focused on using a plant based component as a natural coagulant that is sustainable and environment-friendly. This work focuses on the extraction, isolation and purification of a natural coagulant from seed kernels of Moringa oleifera to enhance its turbidity removal efficiency. The determination of themolecular weight of the purified proteins was done using sodium dodecyl sulfate polyacrylamide gel electrophoresis. The active coagulant proteins were isolated using 30-60% and 60-80% saturation of ammonium sulfate. It was observed that proteins with molecular weight less than 36 kDa have superior coagulation activity. Turbidity removal efficiency of these active coagulant proteins was compared with alum. The possibility of using Moringa oleifera seeds as a natural antimicrobial agent was also investigated.

  16. Low-cost multi-stage filtration enhanced by coagulation-flocculation in upflow gravel filtration

    Directory of Open Access Journals (Sweden)

    L. D. Sánchez

    2012-12-01

    Full Text Available This paper assesses the operational and design aspects of coagulation and flocculation in upflow gravel filters (CF-UGF in a multi-stage filtration (MSF plant. This study shows that CF-UGF units improve the performance of MSF considerably, when the system operates with turbidity above 30 NTU. It strongly reduces the load of particulate material before the water enters in the slow sand filters (SSF and therewith avoids short filter runs and prevents early interruption in SSF operations. The removal efficiency of turbidity in the CF-UGF with coagulant was between 85 and 96%, whereas the average efficiency without coagulant dosing was 46% (range: 21–76%. Operating with coagulant also improves the removal efficiency for total coliforms, E-coli and HPC. No reduction was observed in the microbial activity of the SSF, no obstruction of the SSF bed was demonstrated and SSF runs were maintained between 50 and 70 days for a maximum head loss of 0.70 m. The most important advantage is the flexibility of the system to operate with and without coagulant according to the influent turbidity. It was only necessary for 20% of the time to operate with the coagulant. The CF-UGF unit represented 7% of total construction costs and the O&M cost for the use of coagulant represented only 0.3%.

  17. Performance optimization of coagulant/flocculant in the treatment of wastewater from a beverage industry.

    Science.gov (United States)

    Amuda, O S; Amoo, I A; Ajayi, O O

    2006-02-28

    This study investigated the effect of coagulation/flocculation treatment process on wastewater of Fumman Beverage Industry, Ibadan, Nigeria. The study also compared different dosages of coagulant, polyelectrolyte (non-ionic polyacrylamide) and different pH values of the coagulation processes. The effect of different dosages of polyelectrolyte in combination with coagulant was also studied. The results reveal that low pH values (3-8), enhance removal efficiency of the contaminants. Percentage removal of 78, 74 and 75 of COD, TSS and TP, respectively, were achieved by the addition of 500 mg/L Fe2(SO4)3.3H2O and 93, 94 and 96% removal of COD, TSS and TP, respectively, were achieved with the addition of 25 mg/L polyelectrolyte to the coagulation process. The volume of sludge produced, when coagulant was used solely, was higher compared to the use of polyelectrolyte combined with Fe2(SO4)3.3H2O. This may be as a result of non-ionic nature of the polyelectrolyte; hence, it does not chemically react with solids of the wastewater. Coagulation/flocculation may be useful as a pre-treatment process for beverage industrial wastewater prior to biological treatment.

  18. Removal of algal blooms from freshwater by the coagulation-magnetic separation method.

    Science.gov (United States)

    Liu, Dan; Wang, Peng; Wei, Guanran; Dong, Wenbo; Hui, Franck

    2013-01-01

    This research investigated the feasibility of changing waste into useful materials for water treatment and proposed a coagulation-magnetic separation technique. This technique was rapid and highly effective for clearing up harmful algal blooms in freshwater and mitigating lake eutrophication. A magnetic coagulant was synthesized by compounding acid-modified fly ash with magnetite (Fe(3)O(4)). Its removal effects on algal cells and dissolved organics in water were studied. After mixing, coagulation, and magnetic separation, the flocs obtained from the magnet surface were examined by SEM. Treated samples were withdrawn for the content determination of chlorophyll-a, turbidity, chemical oxygen demand (COD), total nitrogen, and total phosphorus. More than 99 % of algal cells were removed within 5 min after the addition of magnetic coagulant at optimal loadings (200 mg L(-1)). The removal efficiencies of COD, total nitrogen, and phosphorus were 93, 91, and 94 %, respectively. The mechanism of algal removal explored preliminarily showed that the magnetic coagulant played multiple roles in mesoporous adsorption, netting and bridging, as well as high magnetic responsiveness to a magnetic field. The magnetic-coagulation separation method can rapidly and effectively remove algae from water bodies and greatly mitigate eutrophication of freshwater using a new magnetic coagulant. The method has good performance, is low cost, can turn waste into something valuable, and provides reference and directions for future pilot and production scale-ups.

  19. The performance of double layer structure membrane prepared from flowing coagulant

    Science.gov (United States)

    Mieow Kee, Chan; Xeng, Anthony Leong Chan; Regal, Sasiskala; Singh, Balvinder; Raoo, Preeshaath; Koon Eu, Yap; Sok Choo, Ng

    2017-12-01

    Membrane with double layer structure is favourable as it exhibits smooth surface and macrovoids free structure. However, its’ performance in terms of permeability, porosity and strength has not been studied thoroughly. Additionally, the effect of flowing coagulant on the formation of double layer membrane has not been reported. Thus, the objective of this study is to investigate the performance of double layer membranes, which were prepared using flowing coagulant. Results showed that when the coagulant flow changed from laminar to turbulent, the pure water permeation of the membrane increased. It was due to the higher porosity in the membrane, which prepared by turbulent flow (CA-Turbulent) compared to the membrane which fabricated under laminar condition (CA-Laminar). This can be explained by the rapid solvent-coagulant exchange rate between the polymer solution and the turbulent coagulant. In term of strength, the tensile strength of the CA-Turbulent was ~32 MPa, which was 100% higher compared to CA-Laminar. This may due to the presence of large amount of nodules on its surface, which reduced the surface integrity. In conclusion, flowing coagulant altered the membrane properties and adopting turbulent coagulant flow in membrane fabrication would improve the porosity, surface roughness and the strength of the membrane.

  20. Charging and coagulation of radioactive and nonradioactive particles in the atmosphere

    International Nuclear Information System (INIS)

    Kim, Yong-ha; Yiacoumi, Sotira

    2016-01-01

    Charging and coagulation influence one another and impact the particle charge and size distributions in the atmosphere. However, few investigations to date have focused on the coagulation kinetics of atmospheric particles accumulating charge. This study presents three approaches to include mutual effects of charging and coagulation on the microphysical evolution of atmospheric particles such as radioactive particles. The first approach employs ion balance, charge balance, and a bivariate population balance model (PBM) to comprehensively calculate both charge accumulation and coagulation rates of particles. The second approach involves a much simpler description of charging, and uses a monovariate PBM and subsequent effects of charge on particle coagulation. The third approach is further simplified assuming that particles instantaneously reach their steady-state charge distributions. It is found that compared to the other two approaches, the first approach can accurately predict time-dependent changes in the size and charge distributions of particles over a wide size range covering from the free molecule to continuum regimes. The other two approaches can reliably predict both charge accumulation and coagulation rates for particles larger than about 0.04 micrometers and atmospherically relevant conditions. These approaches are applied to investigate coagulation kinetics of particles accumulating charge in a radioactive neutralizer, the urban atmosphere, and an atmospheric system containing radioactive particles. Limitations of the approaches are discussed.