  1. Comparison of two methods of therapy level calibration at 60Co gamma beams

    International Nuclear Information System (INIS)

    Bjerke, H.; Jaervinen, H.; Grimbergen, T.W.M.; Grindborg, J.E.; Chauvenet, B.; Czap, L.; Ennow, K.; Moretti, C.; Rocha, P.

    1998-01-01

    The accuracy and traceability of the calibration of radiotherapy dosimeters is of great concern to those involved in the delivery of radiotherapy. It has been proposed that calibration should be carried out directly in terms of absorbed dose to water, instead of using the conventional and widely applied quantity of air kerma. In this study, the faithfulness in disseminating standards of both air kerma and absorbed dose to water were evaluated, through comparison of both types of calibration for three types of commonly used radiotherapy dosimeters at 60 Co gamma beams at a few secondary and primary standard dosimetry laboratories (SSDLs and PSDLs). A supplementary aim was to demonstrate the impact which the change in the method of calibration would have on clinical dose measurements at the reference point. Within the estimated uncertainties, both the air kerma and absorbed dose to water calibration factors obtained at different laboratories were regarded as consistent. As might be expected, between the SSDLs traceable to the same PSDL the observed differences were smaller (less than 0.5%) than between PSDLs or SSDLs traceable to different PSDLs (up to 1.5%). This can mainly be attributed to the reported differences between the primary standards. The calibration factors obtained by the two methods differed by up to about 1.5% depending on the primary standards involved and on the parameters of calculation used for 60 Co gamma radiation. It is concluded that this discrepancy should be settled before the new method of calibration at 60 Co gamma beams in terms of absorbed dose to water is taken into routine use. (author)

  2. Comparison of two methods of therapy level calibration at 60Co gamma beams

    International Nuclear Information System (INIS)

    Bjerke, H; Jaervinen, H; Grimbergen, T W M; Grindborg, J-E; Chauvenet, B; Czap, L; Ennow, K; Moretti, C; Rocha, P

    1998-01-01

    The accuracy and traceability of the calibration of radiotherapy dosimeters is of great concern to those involved in the delivery of radiotherapy. It has been proposed that calibration should be carried out directly in terms of absorbed dose to water, instead of using the conventional and widely applied quantity of air kerma. In this study, the faithfulness in disseminating standards of both air kerma and absorbed dose to water were evaluated, through comparison of both types of calibration for three types of commonly used radiotherapy dosimeters at 60 Co gamma beams at a few secondary and primary standard dosimetry laboratories (SSDLs and PSDLs). A supplementary aim was to demonstrate the impact which the change in the method of calibration would have on clinical dose measurements at the reference point. Within the estimated uncertainties, both the air kerma and absorbed dose to water calibration factors obtained at different laboratories were regarded as consistent. As might be expected, between the SSDLs traceable to the same PSDL the observed differences were smaller (less than 0.5%) than between PSDLs or SSDLs traceable to different PSDLs (up to 1.5%). This can mainly be attributed to the reported differences between the primary standards. The calibration factors obtained by the two methods differed by up to about 1.5% depending on the primary standards involved and on the parameters of calculation used for 60 Co gamma radiation. It is concluded that this discrepancy should be settled before the new method of calibration at 60 Co gamma beams in terms of absorbed dose to water is taken into routine use

  3. Calculational methods for estimating skin dose from electrons in Co-60 gamma-ray beams

    International Nuclear Information System (INIS)

    Higgins, P.D.; Sibata, C.H.; Attix, F.H.; Paliwal, B.R.

    1983-01-01

    Several methods have been employed to calculate the relative contribution to skin dose due to scattered electrons in Co-60 gamma-ray beams. Either the Klein-Nishina differential scattering probability is employed to determine the number and initial energy of electrons scattered into the direction of a detector, or a Gaussian approximation is used to specify the surface distribution of initial pencil electron beams created by parallel or diverging photon fields. Results of these calculations are compared with experimental data. In addition, that fraction of relative surface dose resulting from photon interactions in air alone is estimated and compared with data extrapolated from measurements at large source-surface distance (SSD). The contribution to surface dose from electrons generated in air is 50% or more of the total skin dose for SSDs greater than 80 cm

  4. Simulating 60 Co gamma irradiation systems

    International Nuclear Information System (INIS)

    Omi, Nelson M.; Rela, Paulo R.

    2000-01-01

    The use of Cadgamma, a software dedicated to simulate 60 Co gamma irradiation systems, can lead to an optimized process and simulating, in a few hours, many configurations setups for the irradiation elements. The software can also simulate changes in the path of the product and the influence of any steady body like the support of the product support and source shoulders. These simulations minimize the number of dose mapping tests in industrial applications and allow the study of unusual setups. Cadgamma was developed at IPEN to simulate it is multipurpose 60 Co irradiation system, under construction and planned to be operating by the second half of 2001. The software was used on project stage and will help to optimize the irradiation process for each product to be treated. (author)

  5. Responses of commercial broiler chicks to 60Co gamma-rays

    International Nuclear Information System (INIS)

    Shebaita, M.K.; Kamar, G.A.R.; El-Barkouky, E.E.M.

    1981-01-01

    A total of 360 chicks of Nichols line at one-day old were used in this study. Within each sex, the chicks were divided into three exposure treatments (non-irradiated, 400 rads and 800 rads). The source of irradiation was 60 Co gamma-rays. The results can be summarized as follows: Of the 360 chicks used in this study, only 10 chicks died during the experimental period. Radiation induced a reduction in body weight in both sexes during the growth period. Gamma-rays reduce the feed intake in both sexes. Moreover, the feed conversion ratio for the irradiated chicks was higher than that the non-irradiated birds. While red blood cells and hemoglobin content were higher in the irradiated chicks, white blood cells count and especially lymphocytes did not affect by 60 Co gamma-rays. Gamma-rays had no effect on carcass, bone, meat and giblets as fractions of body weight in both sexes. Moreover, meat water content decreased and meat fat content increased in irradiated chicks. The total length and the total weight of the GI tract decreased due to 60 Co gamma-rays. The response of the different regions of the GI tract to this rays is different. Moreover, the effect of this radiation on the GI tract is dependent upon the body weight irrespective of the sex. (orig./MG) [de

  6. Experimental calibration and determination of the relative response for Lif: Mg, Ti(TLD-100) dosemeters at 60Co gamma and 60 kVp X-ray energies

    International Nuclear Information System (INIS)

    Marco, M.L.; Gonzalez, L.; Delgado, V.; Vano, E.; Moran, P.

    1985-01-01

    The thermoluminescence efficiency of LiF: Mg, Ti (TLD-100) dosemeters has been determined for photon beams from 60 Co gamma rays and 60 kVp X-rays. It has been proven that light yield varies as a function of the photon energy. An experiment was performed using an X-ray beam whose spectrum has been determined by an X-ray fluorescence method. This enabled a direct calculation of the absorbed doses in the T1 material for the different operation conditions. These values and the experimental ones from measuring T1 intensities have been used to obtain the efficiency for energy X-ray spectrum. From the above values, the dosemeter T1 response, relative to 60 Co, has been evaluated. (author)

  7. Measurement of Cerenkov Radiation Induced by the Gamma-Rays of Co-60 Therapy Units Using Wavelength Shifting Fiber

    Directory of Open Access Journals (Sweden)

    Kyoung Won Jang

    2014-04-01

    Full Text Available In this study, a wavelength shifting fiber that shifts ultra-violet and blue light to green light was employed as a sensor probe of a fiber-optic Cerenkov radiation sensor. In order to characterize Cerenkov radiation generated in the developed wavelength shifting fiber and a plastic optical fiber, spectra and intensities of Cerenkov radiation were measured with a spectrometer. The spectral peaks of light outputs from the wavelength shifting fiber and the plastic optical fiber were measured at wavelengths of 500 and 510 nm, respectively, and the intensity of transmitted light output of the wavelength shifting fiber was 22.2 times higher than that of the plastic optical fiber. Also, electron fluxes and total energy depositions of gamma-ray beams generated from a Co-60 therapy unit were calculated according to water depths using the Monte Carlo N-particle transport code. The relationship between the fluxes of electrons over the Cerenkov threshold energy and the energy depositions of gamma-ray beams from the Co-60 unit is a near-identity function. Finally, percentage depth doses for the gamma-ray beams were obtained using the fiber-optic Cerenkov radiation sensor, and the results were compared with those obtained by an ionization chamber. The average dose difference between the results of the fiber-optic Cerenkov radiation sensor and those of the ionization chamber was about 2.09%.

  8. Influence of 60Co gamma radiation on Zabrotes subfasciatus (Bohemann, 1833) (Coleoptera, Curculionidae) and beams Phaseolus vulgaris

    International Nuclear Information System (INIS)

    Moraes Rego, A.F. de; Rodrigues, Z.A.; Oliveira, M.L. de; Santana, M.D.

    1986-01-01

    Influence of gamma radiation on Zabrotes subfasciatus (Boh, 1833) (Coleoptera Bruchidae) and the beans Phaseolus vulgaris (L.). The effects of 60 CO gamma radiation, 50 Gy, on both Phaseolus vulgaris (L.) seedbeans and adults of Zabrotes subfasciatus were studied using the no free choise method. Radiation decreased insect fertility hence insect population and it damage loss of weight and germination of seedbeans. However, radiation resulted in abnamal seedlings, showing various degrees of morphological malformation, although there was no effect on germination rates or seedling vigor. (Author) [pt

  9. Responses of commercial broiler chicks to /sup 60/Co gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    Shebaita, M.K.; Kamar, G.A.R.; El-Barkouky, E.E.M.

    1981-12-01

    A total of 360 chicks of Nichols line at one-day old were used in this study. Within each sex, the chicks were divided into three exposure treatments (non-irradiated, 400 rads and 800 rads). The source of irradiation was /sup 60/Co gamma rays. The results can be summarized as follows: Of the 360 chicks used in this study, only 10 chicks died during the experimental period. Radiation induced a reduction in body weight in both sexes during the growth period. Gamma rays reduce the feed intake in both sexes. Moreover, the feed conversion ratio for the irradiated chicks was higher than that the non-irradiated birds. While red blood cells and hemoglobin content were higher in the irradiated chicks, white blood cells count and especially lymphocytes were not affected by /sup 60/Co gamma rays. Gamma rays had no effect on carcass, bone, meat and giblets as fractions of body weight in both sexes. Moreover, meat water content decreased and meat fat content increased in irradiated chicks. The total length and the total weight of the GI tract decreased due to /sup 60/Co gamma rays. The response of the different regions of the GI tract to these rays is different. Moreover, the effect of this radiation on the GI tract is dependent upon the body weight irrespective of the sex.

  10. Effect of /sup 60/Co. gamma. -rays on polyphenyl methacrylate obtained by. gamma. -ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Raghunath, S.; Rao, M.H.; Rao, K.N. (Bhabha Atomic Research Centre, Bombay (India). Chemistry Div.)

    1983-01-01

    Polyphenyl methacrylate of different molecular weights Msub(n) 13000, 34500 and crosslinked polymer prepared by /sup 60/Co ..gamma..-irradiation has been irradiated with /sup 60/Co ..gamma..-rays at 300 K. G(scission) of the 13000 molecular weight polymer was 15. The crosslinked polymer undergoes both degradation and crosslinking. G(x) value determined for that polymer is approx. 9. The gaseous product consists largely of CO with some CO/sub 2/ and H/sub 2/. Hydrocarbon gases were not detected. The yield of H/sub 2/ is only to the extent of 2 to 5% of the total gas and it is assumed that majority of scission takes place at the ester linkage. On the basis of the estimation of phenol and benzene, a mechanism for degradation and crosslinking is proposed.

  11. Functionalization and magnetization of carbon nanotubes using Co-60 gamma-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chen, C.Y.; Fu, M.J.; Tsai, C.Y. [Division of Isotope Application, Institute of Nuclear Energy Research, Atomic Energy Council, P.O. BOX 3-27 Longtan, Taoyuan County 32546, Taiwan (R.O.C.) (China); Lin, F.H. [Institute of Biomedical Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 10617, Taiwan (R.O.C.) (China); Chen, K.Y., E-mail: chenky@iner.gov.tw [Division of Isotope Application, Institute of Nuclear Energy Research, Atomic Energy Council, P.O. BOX 3-27 Longtan, Taoyuan County 32546, Taiwan (R.O.C.) (China)

    2014-10-01

    Functionalized magnetic carbon nanotubes (CNTs) can be used in the biological and biomedical fields as biosensors, drug delivery systems, etc., which makes research into processes for manufacturing modified CNTs quite important. In this paper, Co-60 gamma irradiation is shown to be an effective tool for fabricating functionalized and magnetized CNTs. After the Co-60 gamma irradiation, the presence of carboxylic functional groups on the CNT walls was confirmed by their Fourier transform infrared spectra, and the presence of Fe{sub 3}O{sub 4} was verified by the X-ray diffraction patterns. The functionalized and magnetized CNTs produced using Co-60 gamma irradiation have excellent dispersion properties. The techniques for functionalizing and magnetizing CNTs are introduced in this paper, and applications of the modified CNTs will be reported after more data are gathered. - Highlights: Dispersion ability of carbon nanotubes (CNTs) was improved by functionalization. CNTs were easily manipulated by precipitation of magnetic nanoparticles. Our product can be used as versatile biosensor substrate for biomarker screening.

  12. Different gamma ray (60 Co) dose effects on Sorghum genotype germination

    International Nuclear Information System (INIS)

    Tabosa, Jose Nildo; Gomes, Roberto Vicente; Reis, Odemar Vicente dos; Colaco, Waldeciro

    2004-01-01

    In agriculture, applying irradiation is a very valuable way of obtaining vegetable products for human and animal consumption. Cobalt-60, one of the main sources of gamma-rays, is considered an important tool in plant breeding programs, which have the objective of promoting genetic variability of cultivars with resistance to adverse environments. In this research, the effects of different 60 Co doses on germination vigor and seed germination velocity of forage sorghum genotypes were evaluated. The study was carried out at the IPA (Empresa Pernambucana de Pesquisa Agropecuaria) in Recife, Pernambuco, Brazil. The work was installed in germination boxes, following laboratory recommendations. Thus, a experiment involving three sorghum genotypes (IPA 467-4-2, IPA 02-03-01, and Sudan 4202), five 60 Co doses (Zero, 150, 300, 350, and 400 Gy), was set up. The sees were irradiated before the beginning of the experiment being exposed to gamma rays from a 60 Co-source (cobalt irradiator) at DEN (Nuclear Engineering Department) of the UFPE (Pernambuco Federal University), Brazil. The work also had the objective of evaluating the sorghum genotypes x 60 Co dose interaction. The main results obtained showed that the sorghum genotype IPA 02-03-01 presented the greatest values of germination and vigor percentages, and seed germination velocity, when compared to the others evaluated, on 350 and 400 Gy of 60 Co doses. (author)

  13. Introduction of beam flatness filter for 60Co teletherapy beam and its efficacy in clinical radiotherapy

    International Nuclear Information System (INIS)

    Sathiyan, S.; Ravichandran, R.; Ravikumar, M.

    2003-01-01

    In the western countries cobalt-60 machines have become obsolete, whereas in India we have about 250 machines operational for clinical radiotherapy. The basic differences of 6 MV x-ray beam and cobalt-60 beam are: a) build-up d max point, b) flatness of beam at depths, and c) sharpness of the beam edge. We looked at the homogeneity of delivered dose in the target volume in a 3 field SAD technique for 60 Co (80 cm, 100 cm) and 6 MV treatments. More dose variations are seen in 60 Co treated volume. The excess curvature of isodose curves of 60 Co at depths may be one of the reasons for this inhomogeneity in dose to target volume. Therefore, there is need for achieving perfect flatness in the isodose curves at desired depths. A flattening filter was fabricated using dental wax impression material to account for depths of curvature of 50% 60 Co isodose curve. The filter was fabricated for the Theratron 780C machine for necessary flatness. The beam flatness with filter was measured with a) ionization and b) TL dosimetry methods. The flattened beam profile was compared with 6 MV x-ray beam (Clinac-1800, M/s Varian, USA). Our measurements show uniform flatness of cobalt-60 isodose curve at desired depth and useful radiation field width comparable to 6 MV x-ray photon profile at full width at half maximum (FWHM). If this concept is extendable to short field widths, it appears that there is scope for use of such filter in the treatments of oesophagus, larynx, and pituitary tumours to achieve dose homogeneity. Using this flatness filter and penumbra trimmer, we may achieve better quality cobalt-60 beam for radiotherapy. (author)

  14. Calculational methods for estimating skin dose from electrons in Co-60 gamma-ray beams

    International Nuclear Information System (INIS)

    Higgins, P.D.; Sibata, C.H.; Attix, F.H.; Paliwal, B.R.

    1983-01-01

    Several methods have been employed to calculate the relative contribution to skin dose due to scattered electrons in Co-60 γ-ray beams. Either the Klein--Nishina differential scattering probability is employed to determine the number and initial energy of electrons scattered into the direction of a detector, or a Gaussian approximation is used to specify the surface distribution of initial pencil electron beams created by parallel or diverging photon fields. Results of these calculations are compared with experimental data. In addition, that fraction of relative surface dose resulting from photon interactions in air alone is estimated and compared with data extrapolated from measurements at large source--surface distance (SSD). The contribution to surface dose from electrons generated in air is 50% or more of the total skin dose for SSDs greater than 80 cm

  15. A comparison of ionizing radiation damage in CMOS devices from 60Co gamma rays, electrons and protons

    International Nuclear Information System (INIS)

    He Baoping; Yao Zhibin; Zhang Fengqi

    2009-01-01

    Radiation hardened CC4007RH and non-radiation hardened CC4011 devices were irradiated using 60 Co gamma rays, 1 MeV electrons and 1-9 MeV protons to compare the ionizing radiation damage of the gamma rays with the charged particles. For all devices examined, with experimental uncertainty, the radiation induced threshold voltage shifts (ΔV th ) generated by 60 Co gamma rays are equal to that of 1 MeV electron and 1-7 MeV proton radiation under 0 gate bias condition. Under 5 V gate bias condition, the distinction of threshold voltage shifts (ΔV th ) generated by 60 Co gamma rays and 1 MeV electrons irradiation are not large, and the radiation damage for protons below 9 MeV is always less than that of 60 Co gamma rays. The lower energy the proton has, the less serious the radiation damage becomes. (authors)

  16. Comparative effectiveness of gamma-rays and electron beams in food irradiation

    International Nuclear Information System (INIS)

    Hayashi, Toru

    1991-01-01

    Ionizing radiations which can be used for the treatment of foods are gamma-rays from Co-60 and Cs-137, accelerated electrons from a machine at an energy of 10 MeV or lower and X-rays from a machine at an energy of 5 MeV or lower. The Joint FAO/IAEA/WHO Expert Committee on the Wholesomeness of Irradiated Food held in 1980 concluded that the foods irradiated at overall average doses up to 10 kGy with the radiation listed above are wholesome for human consumption. While most of the commercial food irradiations are conducted with gamma-rays from Co-60, accelerated electrons are increasingly utilized for treating foods. An important difference between gamma-rays and accelerated electrons is the penetration capacity in materials. The penetration capacity of gamma-rays is much higher than that of accelerated electrons. Another important difference is the dose rate. The dose rates of gamma-rays from commercial Co-60 sources are 1-100 Gy/min, while those of electron beams from electron accelerators are 10 3 -10 6 Gy/s. Ideally a comparison of the effect of different types of ionizing radiation should be carried out at the same dose rate but this has been difficult due to the design of irradiators. It is very difficult to draw a definite conclusion on the difference in the effectiveness in food irradiation between gamma-rays and electron beams based on published data. This chapter deals with as many reports as possible on the comparative effectiveness of gamma-rays and electron beams and on the effect of dose rate on chemical reactions and living organisms, whether or not they demonstrate any dependency of the effect of irradiation on dose rate and type of radiation. (author)

  17. Co-60 gamma radiation assisted diffusion of iodine in polypropylene

    Energy Technology Data Exchange (ETDEWEB)

    Mathakari, N.L.; Bhoraskar, V.N. [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Pune, Maharashtra 411007 (India); Dhole, S.D., E-mail: sanjay@physics.unipune.ernet.i [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Pune, Maharashtra 411007 (India)

    2010-09-15

    Thin films of polypropylene having dimensions 50 mm x 15 mm x 350 {mu}m were immersed in 1 N iodine solution and then irradiated with Co-60 gamma radiation for the periods of 48, 96 and 144 h at the doses varying from 14.4 to 43.2 kGy. The films were also kept immersed in iodine solution for similar periods but without irradiation. Furthermore, the films were also directly-irradiated with Co-60 gamma radiation for similar periods and doses. The radiation-iodinated, plain-iodinated and directly-irradiated samples were characterized by using various techniques such as weight gain EDS, SEM, FTIR, UV-visible spectroscopy, contact angle and XRD. Weight gain, EDS and SEM collectively reveal that gamma irradiation enhances iodine intake in polypropylene. FTIR, EDS and contact angle measurements indicate that presence of iodine during irradiation resists radiation induced carbonylation of polypropylene. FTIR also shows presence of HOI (Hypoiodous acid) species instead of expected C-I bonds. UV-visible analysis unambiguously shows that presence of iodine enhances radiation induced band gap reduction process of polypropylene. XRD indicates that iodine decreases the crystallinity of polypropylene.

  18. Influence of source configuration on spectral composition of gamma-ray beams from 60Co teletherapy units

    International Nuclear Information System (INIS)

    Ehrlich, M.; Soares, C.G.; Jackson, B.; Lanoue, P.

    1978-01-01

    Measurements were made of the photon spectra of simulated 60 Co teletherapy beams. Various source configurations and source environments of practical interest were employed for this purpose. The sources consisted of activated cobalt pellets packed into steel capsules. Several combinations of capsule diameters and heights of pellet layers were used. The spacer materials filling the remaining capsule volume were chosen to be of high, intermediate, or low atomic number. The capsules could be inserted, one at a time, into a compartment of either tungsten or brass, simulating the central section of popular commercial 60 Co teletherapy units. There also was some choice in the atomic number of the structural elements holding the capsules in place in the compartment. The largest contribution of scattered photons was found to occur when the materials close to the source pellets had atomic numbers in the vicinity of 30. (author)

  19. Mantle treatment of Hodkin's disease with 60Co gamma rays

    International Nuclear Information System (INIS)

    Svahn-Tapper, G.

    1979-01-01

    60 Co mantle beams were used in the radiation treatment of patients| with Hodgkin's disease. A technique using beam-flattening filters is described. The dosimetry was based on dose plans drawn up manually for each patient. The good dosimetric accuracy of the method was verified by in vivo measurements of absorbed dose at the oesophagi of 60 patients. Split-course treatment with 40 Gy was given in 27 fractions over 71 days. Results and side-effects in 90 patients are analyzed. The local recurrence rate was 3 %. (author)

  20. [Chinese medicinal monomer and compound for 60Co-gamma-induced spermatogenic disturbance in mice].

    Science.gov (United States)

    Zhang, Wei-xing; Wang, Hua-li; Wang, Rui; Li, Rui; He, Wei; Zhang, Tian-biao

    2010-05-01

    To explore the effects of the monomer and compound of the Chinese herbal drugs resveratrol, lycium barbarum polysaccharide (LBP) and icariin on 60Co-gamma-induced spermatogenic disturbance in mice based on the theory of modern Chinese medicine. A total of 105 male Kunming mice were randomly divided into seven groups, with 15 in each. Group A were normally raised and Groups B, C, D, E, F and G irradiated by 60Co-gamma 6 Gy followed by 60Co-gamma 4 Gy at the interval of 7 days. A week later, Groups C, D, E, F and G received intragastrically the suspension of resveratrol, resveratrol + LBP, resveratrol + icariin, resveratrol + LBP + icariin and resveratrol + LBP + icariin + L-carnitine, respectively, at the dose of 80 mg/(kg x d) for 60 days. The general condition, physical signs and body weight changes of the mice were recorded, and 24 hours after the intragastric medication, their testes were harvested to obtain the testicular weight and indexes, the levels of FSH, LH, T and E2 determined by ELISA, the T/E2 ratio calculated, and the histology of the testis tissues observed under the microscope. The testicular indexes of the mice were decreased by radiation-induced damage, but restored to some extent after intragastric medication, especially in Groups E, F and G. The levels of FSH, LH and T were obviously improved by LBP. The T level and testis weight were increased by Icariin. The level of T/E2 was elevated in Groups E, F and G. The best results were achieved in Group F, which exhibited almost complete recovery from reproductive endocrine disorder and spermatogenic damage. The Chinese medicinal monomer is effective for 60Co-gamma-induced spermatogenic disturbance in mice, and the compound suspension of resveratrol + LBP + icariin produces the best result.

  1. Analysis of the microbial growth in 60Co gamma-irradiated foods by calorimetry

    International Nuclear Information System (INIS)

    Furuta, M.; Hamasaki, K.; Wirkner, S.; Constantinoiu, E.; Takahashi, K.; Hayashi, T.

    2002-01-01

    Using a heat conduction calorimeter equipped with 24 sample units the heat evolutions from growing 60Co gamma-irradiated bioburden of black pepper seeds and frozen beef were detected in the form of growth thermograms. 60Co gamma-irradiation affected the growth pattern in which a dose-dependent reduction of the growth rate constant was observed together with the retardation in growth, indicating a combination of bactericidal and bacteriostatic effects. We successfully determined the minimal inactivation doses for the two food samples using the relationship between the irradiation dose and the retardation in growth talpha, or the growth rate constant mu obtained from the growth thermograms. These results strongly suggested the possibility of calorimetry as a measure of predictive microbiology in food irradiation

  2. Calculation of uncertainties in the protocol of dosimetry for Co 60 beams in Radiotherapy

    International Nuclear Information System (INIS)

    Velazquez M, S.; Carrera M, F.; Sanchez S, J.

    1998-01-01

    The objective in this work is to show how the uncertainty is possible to know in the determination of the absorbed dose in Co 60 photon beams and to establish in a rational form, tolerance levels for this. It is took as base the spanish protocol of dosimetry in Radiotherapy. We have been centered in a Co 60 beam. We utilized the statistical theory of little samples. We allowed to suggest a new approach about the treatment of the tolerance levels and the uncertainty of the measurement. After two years of experience in the practical hospitable application we have gotten to put around 1 % uncertainty in the absolute dosimetry of the Co 60 beam. The presented protocol allows to execute the accuracy requirements in the determination of absorbed doses. (Author)

  3. Effect of Co-60 irradiation on hyperimmune antimeningococcus globulins-gamma

    International Nuclear Information System (INIS)

    Galguera, M.; Le Riverand, E.; Padron, S.

    1990-01-01

    Globulins-gamma from voluntary blood donors immunized with the Cuban BC antimeningococcus vaccine is now being used in our country for the treatment of the meningococcus disease. This study of the effect of Co-60 irradiation on antimeningococcus globulins-gamma was carried out to try to eliminate the inconvenience shown by the traditionally used sterilization procedures (losses in the filter and persistence of viral contamination). globulins-gamma was obtained by ethanol fractionation and was irradiated at a different dose in solution with different stabilizers and it was also lyophilized. Results of the chemical controls carried out lead to the conclusion that it is possible to use radiosterilization on this product in a lyophilized form. The preservation of bactericidal activity, even after the highest irradiation doses, confirms the above mentioned. 13 refs

  4. A comparison of large-scale electron beam and bench-scale 60Co irradiations of simulated aqueous waste streams

    Science.gov (United States)

    Kurucz, Charles N.; Waite, Thomas D.; Otaño, Suzana E.; Cooper, William J.; Nickelsen, Michael G.

    2002-11-01

    The effectiveness of using high energy electron beam irradiation for the removal of toxic organic chemicals from water and wastewater has been demonstrated by commercial-scale experiments conducted at the Electron Beam Research Facility (EBRF) located in Miami, Florida and elsewhere. The EBRF treats various waste and water streams up to 450 l min -1 (120 gal min -1) with doses up to 8 kilogray (kGy). Many experiments have been conducted by injecting toxic organic compounds into various plant feed streams and measuring the concentrations of compound(s) before and after exposure to the electron beam at various doses. Extensive experimentation has also been performed by dissolving selected chemicals in 22,700 l (6000 gal) tank trucks of potable water to simulate contaminated groundwater, and pumping the resulting solutions through the electron beam. These large-scale experiments, although necessary to demonstrate the commercial viability of the process, require a great deal of time and effort. This paper compares the results of large-scale electron beam irradiations to those obtained from bench-scale irradiations using gamma rays generated by a 60Co source. Dose constants from exponential contaminant removal models are found to depend on the source of radiation and initial contaminant concentration. Possible reasons for observed differences such as a dose rate effect are discussed. Models for estimating electron beam dose constants from bench-scale gamma experiments are presented. Data used to compare the removal of organic compounds using gamma irradiation and electron beam irradiation are taken from the literature and a series of experiments designed to examine the effects of pH, the presence of turbidity, and initial concentration on the removal of various organic compounds (benzene, toluene, phenol, PCE, TCE and chloroform) from simulated groundwater.

  5. A comparison of large-scale electron beam and bench-scale 60Co irradiations of simulated aqueous waste streams

    International Nuclear Information System (INIS)

    Kurucz, Charles N.; Waite, Thomas D.; Otano, Suzana E.; Cooper, William J.; Nickelsen, Michael G.

    2002-01-01

    The effectiveness of using high energy electron beam irradiation for the removal of toxic organic chemicals from water and wastewater has been demonstrated by commercial-scale experiments conducted at the Electron Beam Research Facility (EBRF) located in Miami, Florida and elsewhere. The EBRF treats various waste and water streams up to 450 l min -1 (120 gal min -1 ) with doses up to 8 kilogray (kGy). Many experiments have been conducted by injecting toxic organic compounds into various plant feed streams and measuring the concentrations of compound(s) before and after exposure to the electron beam at various doses. Extensive experimentation has also been performed by dissolving selected chemicals in 22,700 l (6000 gal) tank trucks of potable water to simulate contaminated groundwater, and pumping the resulting solutions through the electron beam. These large-scale experiments, although necessary to demonstrate the commercial viability of the process, require a great deal of time and effort. This paper compares the results of large-scale electron beam irradiations to those obtained from bench-scale irradiations using gamma rays generated by a 60 Co source. Dose constants from exponential contaminant removal models are found to depend on the source of radiation and initial contaminant concentration. Possible reasons for observed differences such as a dose rate effect are discussed. Models for estimating electron beam dose constants from bench-scale gamma experiments are presented. Data used to compare the removal of organic compounds using gamma irradiation and electron beam irradiation are taken from the literature and a series of experiments designed to examine the effects of pH, the presence of turbidity, and initial concentration on the removal of various organic compounds (benzene, toluene, phenol, PCE, TCE and chloroform) from simulated groundwater

  6. Fricke dosimetry: the difference between G(Fe3+) for 60Co gamma-rays and high-energy x-rays.

    Science.gov (United States)

    Klassen, N V; Shortt, K R; Seuntjens, J; Ross, C K

    1999-07-01

    A calibration of the Fricke dosimeter is a measurement of epsilon G(Fe3+). Although G(Fe3+) is expected to be approximately energy independent for all low-LET radiation, existing data are not adequate to rule out the possibility of changes of a few per cent with beam quality. When a high-precision Fricke dosimeter, which has been calibrated for one particular low-LET beam quality, is used to measure the absorbed dose for another low-LET beam quality, the accuracy of the absorbed dose measurement is limited by the uncertainty in the value of G(Fe3+). The ratio of G(Fe3+) for high-energy x-rays (20 and 30 MV) to G(Fe3+) for 60Co gamma-rays, G(Fe3+)MV(Co), was measured to be 1.007(+/-0.003) (confidence level of 68%) using two different types of water calorimeter, a stirred-water calorimeter (20 MV) and a sealed-water calorimeter (20, 30 MV). This value is consistent with our calculations based on the LET dependence of G(primary products) and, as well, with published measurements and theoretical treatments of G(Fe3+).

  7. Physics of gamma knife approach on convergent beams in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Wu, A.; Lindner, G.; Maitz, A.H.; Kalend, A.M.; Lunsford, L.D.; Flickinger, J.C.; Bloomer, W.D.

    1990-01-01

    The Presbyterian-University Hospital of Pittsburgh installed the first clinically designated Leksell gamma knife in the U.S. in August 1987. Gamma knife radiosurgery involves stereotactic target localization with the Leksell frame and subsequent closed-skull single-treatment session irradiation of a lesion with multiple highly focused gamma ray beams produced from 60Co sources. The hemispherical array of sources, the large number of small-diameter beams, and the steep dose gradients surrounding a targeted lesion make physical characterization of the radiation field complex. This paper describes the physical features and the operation of the gamma knife as well as the calibration procedures of the very small, well-collimated beams. The results of studies using in-phantom ion chamber, diode, film, and lithium fluoride thermoluminescent dosimetry were all in close agreement. Both single-beam and multiple-beam dose profiles were measured and reported for the interchangeable helmets, which have 4-, 8-, 14-, and 18-mm-diameter collimators. We also describe the dose calculation and treatment planning algorithm in the treatment planning system. Measurements of the accuracy of mechanical and radiation alignment are also performed and discussed

  8. Dosimetric response of united, commercially available CTA foils for 60Co gamma rays

    International Nuclear Information System (INIS)

    Peimel-Stuglik, Z.

    2001-01-01

    The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for 60 Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for 60 Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life. (author)

  9. Effects of 60Co gamma radiation on crotamine

    Directory of Open Access Journals (Sweden)

    Boni-Mitake M.

    2001-01-01

    Full Text Available Ionizing radiation can change the molecular structure and affect the biological properties of biomolecules. This has been employed to attenuate animal toxins. Crotamine is a strongly basic polypeptide (pI 10.3 from Crotalus durissus terrificus venom composed of 42 amino acid residues. It induces skeletal muscle spasms leading to a spastic paralysis of hind limbs in mice. The objective of the present study was to carry out a biochemical study and a toxic activity assay on native and irradiated crotamine. Crotamine was purified from C.d. terrificus venom by Sephadex G-100 gel filtration followed by ion-exchange chromatography, and irradiated at 2 mg/ml in 0.15 M NaCl with 2.0 kGy gamma radiation emitted by a 60Co source. The native and irradiated toxins were evaluated in terms of structure and toxic activity (LD50. Irradiation did not change the protein concentration, the electrophoretic profile or the primary structure of the protein although differences were shown by spectroscopic techniques. Gamma radiation reduced crotamine toxicity by 48.3%, but did not eliminate it.

  10. The comparison of Co-60 and 4MV photons matching dosimetry during half-beam technique

    International Nuclear Information System (INIS)

    Cakir, Aydin; Bilge, Hatice; Dadasbilge, Alpar; Kuecuecuek, Halil; Okutan, Murat; Merdan Fayda, Emre

    2005-01-01

    In this phantom study, we tried to compare matching dosimetry differences between half-blocking of Co-60 and asymmetric collimation of the 4MV photons during craniospinal irradiation. The dose distributions are compared and discussed. Firstly, some gaps with different sizes are left between cranial and spinal field borders. Secondly, the fields are overlapped in the same sizes. We irradiate the films located in water-equivalent solid phantoms with Co-60 and 4MV photon beams. This study indicates that the field placement errors in +/- 1mm are acceptable for both Co-60 and 4MV photon energies during craniospinal irradiation with half-beam block technique. Within these limits the dose variations are specified in +/- 5%. However, the setup errors that are more than 1mm are unacceptable for both asymmetric collimation of 4MV photon and half-blocking of Co-60

  11. Accumulation and dissipation of positive charges induced on a PMMA build-up cap of an ionisation chamber by 60Co gamma-ray irradiation

    International Nuclear Information System (INIS)

    Morishita, Y.; Takata, N.

    2013-01-01

    The signal current from an ionisation chamber with a PMMA build-up cap decreases with irradiation time due to electric fields produced by positive charges induced on the cap. In the present study, it was confirmed that the signal current decreases faster for irradiation using narrower 60 Co gamma-ray beams. This is because the number of secondary electrons that are emitted from surrounding materials and penetrate the build-up cap is smaller in a narrower gamma-ray beam, so that fewer positive charges are neutralised. The ionisation chamber was first subjected to continuous gamma-ray irradiation for 24 h, following which it was irradiated with shorter periodic gamma-ray bursts while measuring the current signal. This allowed the coefficients of positive charge accumulation and dissipation to be determined. It was found that the dissipation coefficient has a large constant value during gamma-ray irradiation and decreases asymptotically to a small value after irradiation is stopped. From the coefficients, the minimum signal current was calculated, which is the value when accumulation and dissipation balance each other under continuous irradiation. The time required for the signal current to recover following irradiation was also calculated. (authors)

  12. Effect of spirit irradiation with 60Co gamma-rays

    International Nuclear Information System (INIS)

    Gwardys, S.

    1975-01-01

    A few sorts of spirit were irradiated with a dose of 1 or 5 Mrad of 60 Co gamma-rays. Then the chemical composition of spirits was investigated. It was found that as a result of irradiation the content of acids, esters, acetal aldehydes and methanol increases, while the strength of higher alcohols decreases slightly. The changes of compounds content in particular spirits are dependent on radiation doses and chemical composition before irradiation. It was also discovered that spirit irradiation causes decrease or even disappearance of characteristic - for given spirits - maxima of UV absorption. (Z.M.)

  13. Cobalt-60 and Caesium-137 Gamma Sources; Sources de rayonnement gamma au cobalt-60 et au cesium-137; Gamma-istochniki iz kobal'ta-605 i tseziya-137; Fuentes gamma de cobalto-60 y de cesio-137

    Energy Technology Data Exchange (ETDEWEB)

    Kulish, E E; Fradkin, G M [Academy of Sciences of the USSR, Moscow, Union of Soviet Socialits Republics (Russian Federation)

    1960-07-15

    The paper gives the main technical characteristics of gamma sources produced in the USSR using cobalt-60 and caesium-137 and discusses some of the problems of their production technology. The paper contains information on the radiation spectra of Co{sup 60} and Cs{sup 137} and of the source material from which they are prepared. Data are given on the dependence of the activity of cobalt sources upon the intensity of the neutron beam and the geometrical size of the sample. The yield of caesium by uranium fission is also analyzed. The problem of hermetic sealing of the sources is discussed and a complete nomenclature of all the sources manufactured in the USSR are listed, their size and activity also being indicated. In conclusion a comparison of Co{sup 60} and Cs{sup 137} sources is made. (author) [French] Cette communication expose les caracteristiques techniques fondamentales des sources de rayonnement gamma a base de cobalt-60 et de cesium-137 pro- duites en URSS; on y examine egalement certaines questions relatives a la technologie de leur production. La communication contient des donnees sur la nature du rayonnement des isotopes {sup 60}Co et {sup 137}Cs, ainsi que sur celle des matieres brutes utilisees pour leur preparation. On donne les resultats obtenus lors de l'etude de la variation de l'activite des sources au cobalt en fonction de la valeur du flux de neutrons et des dimensions geometriques de l'echantillon, ainsi que les resultats relatifs a la valeur du rendement en isotopes de cesium lors de la fission des noyaux d'uranium. On etudie ensuite les procedes pour assurer l'hermeticite de ces sources. Suit une nomenclature complete des sources produites en URSS, comportant des indications sur leurs dimensions geometriques et sur les valeurs de leur activite. Enfin, il est procede a une comparaison des sources au {sup 60}Co et au {sup 137}Cs. (author) [Spanish] En este informe se describen las principales caracteristicas tecnicas de las fuentes gamma de

  14. The Co{sup 60} Irradiation Facility and the Gamma Field at Riso; Appareil d'irradiation au cobalt-60 et champ sous irradiation gamma, a Riso; Ustanovka dlya obluchenij, rabotayushchaya na So60, i pole gamma-luchej v rizo; Instalacion de irradiacion con cobalto-60 y campo de irradiacion gamma en el centro de Riso

    Energy Technology Data Exchange (ETDEWEB)

    Brynjolfsson, A; Holm, N W [Danish Atomic Energy Commission, Establishment Riso (Denmark)

    1960-07-15

    The paper describes both the Co{sup 60} irradiation facility and the gamma field at the Agricultural Department of the Research Establishment, Riso. The Co{sup 60} irradiation facility contains 1,800 curies of Co{sup 60.} Details of the construction are given together with the safety precautions which have been included in the design. Dosimetry has been carried out by four different methods: 1. Ionisation chambers, 2. Calorimetry, 3. Fricke dosimeter, 4. Photographic films. A general outline is given of the gamma field, including details of source position. The dose rate is approximately 100 r./hr. at a distance of 1 m. An area of radius 15 m is used for the growing of plants under irradiation. A brief indication is given of the class of products which have been irradiated in the two facilities. (author) [French] Le memoire decrit l'appareil d'irradiation au cobalt-60 et le champ sous irradiation gamma du Departement de l'agriculture de l'Organisme de recherche de Riso. L'appareil d'irradiation au cobalt-60 contient une source de 1 800 curies. Des details sont donnes sur la construction ainsi que sur les dispositifs de protection compris dans le plan. Quatre methodes differentes ont ete utilisees pour la dosimetrie: 1. Chambres d'ionisation 2. Calorimetrie 3. Dosimetrie de Fricke 4. Pellicules photographique s On donne un apercu general du champ gamma, ainsi que des details sur la position de la source. L'intensite de dose est de 100 R/h environ a une distance de 1 m. Une zone d'un rayon de 15 m est utilisee pour la croissance des plantes soumises a l'irradiation. Des indications sommaires sont donnees sur la categorie des produits qui ont ete soumis a l'irradiation dans les deux installations. (author) [Spanish] Los autores describen la instalacion de irradiacion con cobalto-60 y el campo de irradiacion gamma del Departamento de Agronomia del Instituto de Investigaciones de Riso. El dispositivo de irradiacion consiste en una fuente de cobalto-60 de 1 800 curies

  15. Radiation quality of tritium: a comparison with 60Co gamma rays.

    Science.gov (United States)

    Chen, Jing

    2013-09-01

    In a previous study, microdosimetric simulations were performed for tritium uniformly distributed in a medium, and for tritium bound to biologically critical sites of dimensions from 10 nm to 2 µm. Results of local energy density, i.e. energy deposition in microscopic regions, are different for these two cases. Based on the spatial distribution of energy deposition, dose mean lineal energies are calculated for tritium in the forms of tritiated water (HTO) and organically bound tritium (OBT). The dose mean lineal energies of OBT are about a factor of 1.7 higher than those of HTO in a wide range of target dimensions of biological interest. The results are consistent with radiobiological findings that OBT is about twice as effective as HTO. In this study, the same calculations were performed for (60)Co gamma rays in a wide range of target dimensions of biological interest (10 nm to 2 µm). Compared with (60)Co gamma rays, the estimated relative biological effectiveness could vary from 1.3 to 3.5 for HTO, and 2.3 to 5.6 for OBT. The results are consistent with radiobiological findings for various biological endpoints in different biological systems that OBT is about twice as effective as HTO.

  16. Hydrogel wound dressing preparation at the laboratory scale by using electron beam and gamma radiation

    International Nuclear Information System (INIS)

    Rapado Raneque, Manuel; Rodriguez Rodriguez, Alejandro; Peniche Covas, Carlos

    2013-01-01

    The present work describes the preparation of hydrogel based on cross-linked networks of poly (N-vinylpirrolidone), PVP, with polyethyleneglicol and agar with 90% water and PVP nancomposites with a synthetic nanoclay, Laponite XLG, for use as burn dressings. These systems were obtained in two ways: using gamma Co-60 and electron beam radiation. The gelation obtained dose was D g = 1.72 kGy. The elastic modulus of hydrogel was independent of the method of irradiation. It was 0.39 MPa for the hydrogel irradiated with gamma Co-60 and 0.38 MPa for electron beam irradiation. The elastic modulus of the nanocomposite membrane was 1.25 MPa, three times higher. These results indicate that the PVP/Laponite XLG nanocomposite hydrogel membrane is the best choice for wound dressing applications due to its high water sorption capacity and its superior mechanical properties.

  17. Calculation of uncertainties in the protocol of dosimetry for Co 60 beams in Radiotherapy; Calculo de incertidumbres en el protocolo de dosimetria para haces de Co 60 en Radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Velazquez M, S.; Carrera M, F.; Sanchez S, J. [Hospital Juan Ramon Jimenez, Ronda Norte s/n 21005 Huelva (Spain)

    1998-12-31

    The objective in this work is to show how the uncertainty is possible to know in the determination of the absorbed dose in Co 60 photon beams and to establish in a rational form, tolerance levels for this. It is took as base the spanish protocol of dosimetry in Radiotherapy. We have been centered in a Co 60 beam. We utilized the statistical theory of little samples. We allowed to suggest a new approach about the treatment of the tolerance levels and the uncertainty of the measurement. After two years of experience in the practical hospitable application we have gotten to put around 1 % uncertainty in the absolute dosimetry of the Co 60 beam. The presented protocol allows to execute the accuracy requirements in the determination of absorbed doses. (Author)

  18. The optimal dosage of 60 co gamma irradiation for obtaining salt gland mutants of exo-recretohalophyte limonium bicolor (bunge) o. kuntze

    International Nuclear Information System (INIS)

    Yuan, F.; Chen, M.; Yang, J.; Wang, B.

    2015-01-01

    Limonium bicolor (Bunge) O. Kuntze is a typical exo-recretohalophyte with multi-cellular salt glands. It is often used to improve saline-alkali soil. Seeds of L. bicolor were treated with different doses of 60 Co gamma irradiation to determine the LD50 for 60 Co gamma irradiation; the goal was to produce a relatively high number of mutants in salt gland development and salt secretion with a relatively low level of mortality. 60 Co gamma irradiation did not greatly affect germination, but an increase in gamma dose prevented the development of true leaves and reduced the percentage of seedlings that emerged from soil. The LD50 for 60 Co gamma irradiation was 120 Gy. Two mutants (few and many) were obtained under the LD50 using the screening methods - differential interference contrast microscope and leaf discs excretion model. Compared with the wild type, few and many had mutation in salt gland development, and many showed lower salt secretion rate per single salt gland than WT. These mutants would provide insight into the molecular mechanisms of salt gland development and salt secretion and into the development of salt-tolerant crop plants. (author)

  19. [Effect of 60Co gamma-irradiation on dilute aqueous solutions of surfactants].

    Science.gov (United States)

    Sawai, T; Shimokowa, T; Miki, Y; Oseko, K; Sawai, T

    1978-01-01

    Present work deals with the effects of gamma irradiation from 60Co gamma-ray source upon aqueous solutions of three kinds of surfactants. When dilute aqueous solutions of sodium dodecyl sulfate (SDS, anionic), cethyl trimethyl ammonium chloride (CTAC, cationic), and polyoxyethylene lauryl ether (POE, non-ionic) were irradiated with gamma-rays at a room remperature, the residual concentration, products, surface tension, and forming power were examined by colorimetric method, IR spectrophotometric method, gaschromatography, Ross-Miles method, and Traube's stalagnometer etc.. These surfactants were decomposed by the irradiation and thus the surface tension increased and the forming power, on the contrary, decreased with dose. Radiation chemical yields (G-value) of the degradation were about 1 for the solutions of SDS and CTAC, and about 0.3 for the POE solution. From the experimental results, it was found that following chemical reactions seem to occur followed by the radiolysis of water; a) bond cleavage of ester for SDS, of CN for CTAC, and of oxyethylene for POE, b) hydrogen abstraction from the surfactants, c) production of CO bond in the presence of dissolved oxygen.

  20. Radiosensitivity of California Wonder pepper variety to Co-60 gamma rays

    International Nuclear Information System (INIS)

    Puertas Arias, Ana Leonor; Gonzalez Nunez, Luis Manuel; Ramirez Fernandez, Ramiro

    1998-01-01

    Seeds of California wonder pepper variety were irradiated with dosages among 100-800 Gy, to intervals of 100 Gy, in a source of Co 60 gamma rays, with the objective of determining its radiosensitivity and to establish the adequate interval of dosage for the mutation breeding. A decrease of the growing indicators, productivity and plant fertility was observed with the increasing of irradiation dosages and the interval among 130-460 Gy was established as the most adequate

  1. Effect of acute sup(60)Co-gamma-irradiation on the in vivo lipid peroxidation in experimental animals

    International Nuclear Information System (INIS)

    Ronai, Eva; Benkoe, Gy.

    1984-01-01

    The effect of sublethal (6.0 Gy) and LDsub(50/30) (9.0 Gy) doses of sup(60)Co-gamma-irradiation on malondialdehyde (MDA) level was studied in rats. The findings suggest that in the organs investigated (brain, liver, spleen, kidneys, testicles, stomach, small intestines) acute sup(60)Co gamma-irradiation increased the formation of MDA, the main product of lipid peroxidation, in a time-related manner to an extent characteristic of the organ investigated. Differences in the degree and temporal development of the changes allow some conclusions as to the radiosensitivity of individual organs. On this basis it can be assumed that the increase in MDA level caused by irradiation considerably contributes to the development of certain symptoms of radiation sickness. (author)

  2. Cytogenetic comparison of the responses of mouse and human peripheral blood lymphocytes to 60Co gamma radiation

    International Nuclear Information System (INIS)

    Kligerman, A.D.; Halperin, E.C.; Erexson, G.L.; Honore, G.; Westbrook-Collins, B.; Allen, J.W.

    1988-01-01

    Experiments were conducted to compare the chromosome damaging effects of 60 Co gamma radiation on mouse and human peripheral blood lymphocytes (PBLs). Either whole blood or isolated and pelleted mononuclear leucocytes (MNLs) were irradiated with a 60 Co unit to yield exposures of 1, 2, 3, or 4 Gy. In addition, mice were whole-body irradiated in vivo with the same doses so that an in vitro-in vivo comparison could be made. The results indicate that mouse PBLs irradiated in whole blood, whether in vivo or in vitro, respond similarly to 60 Co gamma rays as measured by dicentric chromosome formation. In addition, mouse and human PBLs showed a similar radiosensitivity, but because the mouse PBL data were best fitted to an exponential function and the human PBL data to a quadratic function, direct comparisons were difficult to make. Pelleted MNLs from mice were much less sensitive to the clastogenic effects of gamma radiation than whole blood. This is believed to be due to hypoxic conditions that developed during irradiation and transport. Human PBLs did not show a marked difference whether irradiated in whole blood or as pelleted MNLs in tissue culture medium

  3. Effects of {sup 60} Co gamma radiation on crotamine

    Energy Technology Data Exchange (ETDEWEB)

    Boni-Mitake, M. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Dept. de Radioprotecao Ocupacional; Costa, H.; Spencer, P.J. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Dept. de Bioengenharia; Rogero, J.R [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Diretoria de Materiais; Vassilieff, V.S. [UNESP, Botucatu, SP (Brazil). Instituto de Biociencias. Ceatox - Centro de Assistencia Toxicologica]. E-mail: mbmitake@net.ipen.br

    2001-12-01

    Ionizing radiation can change the molecular structure and affect the biological properties of biomolecules. This has been employed to attenuate animal toxins. Crotamine is a strongly basic polypeptide (p I 10.3) from Crotalus durissus terrificus venom composed of 42 amino acid residues. It induces skeletal muscle spasms leading to a spastic paralysis of hind limbs in mice. The objective of the present study was to carry out a biochemical study and a toxic activity assay on native and irradiated crotamine. Crotamine was purified from C.d. terrificus venom by Sephadex G-100 gel filtration followed by ion-exchange chromatography, and irradiated at 2 mg/ml in 0.15 M NaCl with 2.0 kGy gamma radiation emitted by a 60 Co source. The native and irradiated toxins were evaluated in terms of structure and toxic activity (Ld50). Irradiation did not change the protein concentration, the electrophoretic profile or the primary structure of the protein although differences were shown by spectroscopic techniques. Gamma radiation reduced crotamine toxicity by 48.3%, but did not eliminate it. (author)

  4. Degradation Of α-Chitosan By Combined Treatment With Hydroperoxide And Gamma 60Co Radiation

    International Nuclear Information System (INIS)

    Nguyen Quoc Hien; Dang Van Phu; Bui Phuoc Phuc; Ha Thuc Huy

    2008-01-01

    Chitosan samples prepared from shrimp shell (α-chitosan) with degree of deacetylation (DD) of 70, 84 and 94% were treated with H 2 O 2 1.5% at room temperature for degradation. The oxidative chitosan was irradiated by gamma 60 Co radiation for further reduction of molecular weight. Viscosity-average molecular weight of chitosan was measured by capillary viscometer. Results showed that H 2 O 2 was an effective reagent for chitosan degradation. Radiation degradation yield (G s ) increased for chitosan with higher DD. Interestingly Gs-values for oxidative degraded chitosan were found out of 0.96, 5.73 and 7.80 scissions/100 eV that were remarkably higher compared to 0.20, 1.05 and 1.69 scissions/100 eV for initial chitosan with DD 70, 84 and 94%, respectively. Based on results obtained it can be concluded that combined treatment with hydroperoxide and gamma 60 Co radiation was remarkably effective for degradation of chitosan. (author)

  5. A study on the effect of 60Co gamma ray irradiation on the abrasion of dental polymethylmethacrylate, (3)

    International Nuclear Information System (INIS)

    Kimura, Hiroshi

    1981-01-01

    This report intends to clarify the relationship between the total exposure dose and scratch resistance to the specimens SF, SH, MF and MH, giving coating treatments to P.M.M.A. (dental polymethylmethacrylate) and exposing to the irradiation of 60 Co gamma ray at each dose rate. And based on the results, it is intended to develop coated P.M.M.A. with excellent scratch resistance give by irradiation of radioactive ray. From this study, the following results have been obtained. Irradiation of 60 Co gamma ray would give the best results at the exposure at 1 x 10 6 R. The SF and SH specimens in wet condition exposed to 60 Co gamma ray irradiation at 1 x 10 6 R showed a quantity of abrasion of only 17% that of untreated P.M.M.A. and the barrel test revealed outstanding abrasion and scratch resistance. Abrasion and scratch resistance of coated specimens are better utilized in wet conditions performing three times better than those in dry conditions. (author)

  6. Comparison of W-VC-C composites against Co-60, Se-75 and Sb-125 for gamma radioisotope sources

    Science.gov (United States)

    Demir, Ertugrul; Tugrul, A. Beril; Buyuk, Bulent; Yilmaz, Ozan; Ovecoglu, Lutfi

    2018-02-01

    Tungsten based materials are considered to be the promising materials for nuclear applications due to the good properties. The tungsten composite materials have so many advantages in nuclear technological applications especially fusion reactor systems. In this paper, Tungsten-Vanadium carbide-Graphite (W-VC-C) which include 93% tungsten (W), 6% vanadium carbide (VC) and 1% graphite (C) also which has three different alloying time (6-12-24 hours) were produced by mechanical alloying method. Co-60, Se-75 and Sb-125 gamma radioisotopeswere used as a gamma sources in order to determine behavior of gamma attenuation properties of the composite materials. The experimental results were compared with each other to clarify effects of varying gamma energies on the tungsten based composite materials. The mass attenuation coefficients of the samples were obtained by using XCOM computer code and compared with experimental data. The gamma linear attenuation, the mass attenuation coefficients and half value thickness (HVL) of the samples were evaluated and compared with Co-60, Se-75 and Sb-125 for gamma radioisotopes. Results showed that gamma attenuation coefficients of the samples depend on gamma energies and mechanical alloying time has negatively effect on the gamma shielding properties for the all studied W-VC-C.

  7. Study on the energy dependence of gamma radiation detectors for 137Cs and 60Co

    International Nuclear Information System (INIS)

    Nonato, Fernanda B.C.; Diniz, Raphael E.; Carvalho, Valdir S.; Vivolo, Vitor; Caldas, Linda V.E.

    2009-01-01

    38 Geiger-Mueller radiation detectors and 9 ionization chambers were calibrated, viewing to study the energy dependence of the monitor response for gamma radiation fields ( 137 Cs and 60 Co). The results were considered satisfactory only for ionization chambers and for some Geiger-Mueller detectors

  8. The primary exposure standard for Co-60 gamma radiation: characteristics and measurements procedures

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.

    1983-01-01

    A description is given of a cavity ionization chamber used, as a primary exposure standard, at the Laboratorio di Metrologia delle Radiazioni Ionizzanti of the ENEA in Italy. The primary standard is designed to make absolute measurements of exposure due to the Co-60 gamma radiation. The procedures for the realizationof the exposure unit are also described. Finally results of some international comparisons are reported

  9. Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and 60Co γ-rays

    International Nuclear Information System (INIS)

    Vadrucci, M.; Ronsivalle, C.; Marracino, F.; Montereali, R. M.; Picardi, L.; Piccinini, M.; Vincenti, M. A.; Esposito, G.; De Angelis, C.; Cherubini, R.; Pimpinella, M.

    2015-01-01

    Purpose: To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference 60 Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. Methods: EBT3 film samples were irradiated at the Istituto Nazionale di Fisica Nucleare—Laboratori Nazionali di Legnaro, Italy, with a 5 MeV proton beam generated by a 7 MV Van de Graaff CN accelerator. The nominal dose rates used were 2.1 Gy/min and 40 Gy/min. The delivered dose was determined by measuring the particle fluence and the energy spectrum in air with silicon surface barrier detector monitors. A preliminary study of the EBT3 film beam quality dependence in low-energy protons was conducted by passively degrading the beam energy. EBT3 films were also irradiated at ENEA-National Institute of Ionizing Radiation Metrology with gamma radiation produced by a 60 Co source characterized by an absorbed dose to water rate of 0.26 Gy/min as measured by a calibrated Farmer type ionization chamber. EBT3 film calibration curves were determined by means of a set of 40 film pieces irradiated to various doses ranging from 0.5 Gy to 30 Gy absorbed dose to water. An EPSON Expression 11000XL color scanner in transmission mode was used for film analysis. Scanner response stability, intrafilm uniformity, and interfilm reproducibility were verified. Optical absorption spectra measurements were performed on unirradiated and irradiated EBT3 films to choose the most sensitive color channel to the dose range used. Results: EBT3 GafChromic films show an under response up to about 33% for low-energy protons with respect to 60 Co gamma radiation, which is consistent with the linear energy transfer dependence already observed with higher energy protons, and a negligible dose-rate dependence in

  10. The relative biological effectiveness (RBE) of high-energy electrons, x-rays and Co-60 gamma-rays

    International Nuclear Information System (INIS)

    Kiyono, Kunihiro

    1974-01-01

    Linac (Mitsubishi-Shimizu 15 MeV medical linear accelerator) electron beams with actual generated energies of 8, 10, 12 and 15 MeV were compared with X-ray beams having energies of 8 and 10 MV. The RBE values were calculated from 50 percent hatch-ability (LD 50 ) in silk-worm embryos, 30-days lethality (LDsub(50/30)) in ddY mice, and mean lethal dose (Do) in cultured mouse YL cells or human FL cells. To estimate the RBE in clinical experiments, LRD (leukocyte reduction dose) value was calculated for each patient irradiated on the chest or lumbar vertebrae. It was concluded that there is little difference in practical significance between 8 to 10 MV X-rays and 8 to 15 MeV electrons, and that the biological effects of Linac radiations are about 90 to 100 percent of the effect of 60 Co gamma rays. The RBE values gradually decreased, contrary to the elevation of energy between 8 and 15 MeV for electrons and between 8 and 10 MV for X-rays. These values were compared with those of earlier reviews of work in this field, and were briefly discussed. (Evans, J.)

  11. Effect of sup 60 Co-gamma radiation on the properties of furs

    Energy Technology Data Exchange (ETDEWEB)

    Raina, R.K.; Wali, B.K. (Regional Research Lab., Srinagar (India)); Wani, A.M. (Nuclear Research Lab., Srinagar (India))

    1990-01-01

    Furs pretanned with various combinations of vegetable tanning agents and retanned with alum have been irradiated with {sup 60}Co {gamma}-radiation in the dose range 5.0-114.0 kGy. The physico-chemical modifications induced by the radiation have been assessed by measuring changes in tensile strength, absorption of water, elongation and shrinkage temperature. For investigations, samples have been taken from the same topographic region of the rabbit furs, belonging to the same age and sex. The results are discussed. (author).

  12. Some gamma radiation (60Co) effects on Chrysomya megacephala (Fabricius, 1794) (Diptira-Calliphoridae)

    International Nuclear Information System (INIS)

    Garcia, C.R.

    1987-03-01

    The effect of different gama radiation ( 60 Co) doses on Chrysomya megcephala (Fabricius) have been studied under laboratory conditions, in the Entomology Section of Centro de Energia Nuclear na Agricultura (CENA-USP), Piracicaba, SP, Brasil. The insects were collected close to sucking animals brooding areas, identified and reared on artificial diet, being kept in a temperature (26 +- 2 0 C) and humidity (66 +- 9%) controlled room, with 12L:12D photopheriod. A Gammabeam type 650 Cobalt-60 gamma irradiation source was used, with 28, 196x10 10 Bq activity at the beginning of the experiment. The pupae were submitted to increasing gamma radiation doses. To determine lethal doses, treatments were carried out at four different ages and to determine the sterilizing doses two-three day pupae were used. It was noted pupae radiosensitivity decreased with age, LD 50 varying from 14 - 513 Gy. The sterilizing dose for males was 40 Gy and for females 30 Gy. During the individuals life cycle, it was noted that there was a decrease in life expectancy (e x o ) of adults when the gamma radiation dose was increased. Treated males were more sensitive than females (Crossed with ''normals''), there occurring a marked reduction in the number of eggs and their viability when the used gamma radiation dose was increased. (author) [pt

  13. Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV x rays in concrete for beams of cone angles between 0 degrees and 14 degrees calculated by Monte Carlo simulation.

    Science.gov (United States)

    Jaradat, Adnan K; Biggs, Peter J

    2007-05-01

    The calculation of shielding barrier thicknesses for radiation therapy facilities according to the NCRP formalism is based on the use of broad beams (that is, the maximum possible field sizes). However, in practice, treatment fields used in radiation therapy are, on average, less than half the maximum size. Indeed, many contemporary treatment techniques call for reduced field sizes to reduce co-morbidity and the risk of second cancers. Therefore, published tenth value layers (TVLs) for shielding materials do not apply to these very small fields. There is, hence, a need to determine the TVLs for various beam modalities as a function of field size. The attenuation of (60)Co gamma rays and photons of 4, 6, 10, 15, and 18 MV bremsstrahlung x ray beams by concrete has been studied using the Monte Carlo technique (MCNP version 4C2) for beams of half-opening angles of 0 degrees , 3 degrees , 6 degrees , 9 degrees , 12 degrees , and 14 degrees . The distance between the x-ray source and the distal surface of the shielding wall was fixed at 600 cm, a distance that is typical for modern radiation therapy rooms. The maximum concrete thickness varied between 76.5 cm and 151.5 cm for (60)Co and 18 MV x rays, respectively. Detectors were placed at 630 cm, 700 cm, and 800 cm from the source. TVLs have been determined down to the third TVL. Energy spectra for 4, 6, 10, 15, and 18 MV x rays for 10 x 10 cm(2) and 40 x 40 cm(2) field sizes were used to generate depth dose curves in water that were compared with experimentally measured values.

  14. Comparative analysis of 60Co intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Fox, Christopher; Romeijn, H Edwin; Lynch, Bart; Dempsey, James F; Men, Chunhua; Aleman, Dionne M

    2008-01-01

    In this study, we perform a scientific comparative analysis of using 60 Co beams in intensity-modulated radiation therapy (IMRT). In particular, we evaluate the treatment plan quality obtained with (i) 6 MV, 18 MV and 60 Co IMRT; (ii) different numbers of static multileaf collimator (MLC) delivered 60 Co beams and (iii) a helical tomotherapy 60 Co beam geometry. We employ a convex fluence map optimization (FMO) model, which allows for the comparison of plan quality between different beam energies and configurations for a given case. A total of 25 clinical patient cases that each contain volumetric CT studies, primary and secondary delineated targets, and contoured structures were studied: 5 head-and-neck (H and N), 5 prostate, 5 central nervous system (CNS), 5 breast and 5 lung cases. The DICOM plan data were anonymized and exported to the University of Florida optimized radiation therapy (UFORT) treatment planning system. The FMO problem was solved for each case for 5-71 equidistant beams as well as a helical geometry for H and N, prostate, CNS and lung cases, and for 3-7 equidistant beams in the upper hemisphere for breast cases, all with 6 MV, 18 MV and 60 Co dose models. In all cases, 95% of the target volumes received at least the prescribed dose with clinical sparing criteria for critical organs being met for all structures that were not wholly or partially contained within the target volume. Improvements in critical organ sparing were found with an increasing number of equidistant 60 Co beams, yet were marginal above 9 beams for H and N, prostate, CNS and lung. Breast cases produced similar plans for 3-7 beams. A helical 60 Co beam geometry achieved similar plan quality as static plans with 11 equidistant 60 Co beams. Furthermore, 18 MV plans were initially found not to provide the same target coverage as 6 MV and 60 Co plans; however, adjusting the trade-offs in the optimization model allowed equivalent target coverage for 18 MV. For plans with comparable

  15. Studies of natural and 60Co gamma radio-induced conduction in metaphosphate glasses and silica

    International Nuclear Information System (INIS)

    Mengual Gil, M.A.

    1977-01-01

    A study of natural and 60 Co gamma radio-induced conduction in metaphosphate glasses and silica is presented. The experimental study of natural conduction current in metaphosphate glasses in function of temperature enables to observe two different values of the activation energies in the respective temperature ranges T>223K and T [fr

  16. Study on shelf life extension of papayas irradiated by /sup 60/Co gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    Chang, M.S.; Chen, M.D.; Lin, C.T.; Fu, Y.K.

    1984-11-01

    Papayas are one of the main fresh fruits in Taiwan area. Papaya fruits were treated with hot water to pasteurize peels followed by /sup 60/Co gamma-ray irradiation to extend the ripening time. The purpose of synergetic methods is to extend the shelf life of papaya fruits. This experiment was carried out by seven treatments, which were: (1) control group, (2) hot water treatment only, (3) hot water treatment with a 25 krad ..gamma..-irradiation, (4) hot water treatment with a 50 krad ..gamma..-irradiation, (5) hot water treatment with a 75 krad ..gamma..-irradiation, (6) 75 krad ..gamma..-irradiation only, and (7) hot water treatment with a 100 krad ..gamma..-irradiation. The items of observation were: surface yellowing, surface decaying, quality of texture, and length of period lasted after irradiation for 50% marketable papayas. The results of this study showed that a shelf-life extension of six days could be obtained for papayas subjected to hot water (50 to 55/sup 0/C) treatment and a 100 krad irradiation. 3 refs., 2 figs., 2 tabs.

  17. A gamma beam profile imager for ELI-NP Gamma Beam System

    Science.gov (United States)

    Cardarelli, P.; Paternò, G.; Di Domenico, G.; Consoli, E.; Marziani, M.; Andreotti, M.; Evangelisti, F.; Squerzanti, S.; Gambaccini, M.; Albergo, S.; Cappello, G.; Tricomi, A.; Veltri, M.; Adriani, O.; Borgheresi, R.; Graziani, G.; Passaleva, G.; Serban, A.; Starodubtsev, O.; Variola, A.; Palumbo, L.

    2018-06-01

    The Gamma Beam System of ELI-Nuclear Physics is a high brilliance monochromatic gamma source based on the inverse Compton interaction between an intense high power laser and a bright electron beam with tunable energy. The source, currently being assembled in Magurele (Romania), is designed to provide a beam with tunable average energy ranging from 0.2 to 19.5 MeV, rms energy bandwidth down to 0.5% and flux of about 108 photons/s. The system includes a set of detectors for the diagnostic and complete characterization of the gamma beam. To evaluate the spatial distribution of the beam a gamma beam profile imager is required. For this purpose, a detector based on a scintillator target coupled to a CCD camera was designed and a prototype was tested at INFN-Ferrara laboratories. A set of analytical calculations and Monte Carlo simulations were carried out to optimize the imager design and evaluate the performance expected with ELI-NP gamma beam. In this work the design of the imager is described in detail, as well as the simulation tools used and the results obtained. The simulation parameters were tuned and cross-checked with the experimental measurements carried out on the assembled prototype using the beam from an x-ray tube.

  18. A simple formula for depth dose calculation for Co-60 teletherapy beam dosimetry

    International Nuclear Information System (INIS)

    Tripathi, U.B.; Kelkar, N.Y.

    1979-01-01

    Knowledge of dose at all points of interest in the plane of tumour is essential for treatment planning. A very simple formula for scatter dose calculation along the central axis of a Co-60 beam has been derived. This formula uses primary dose at depth d, scatter air ratio at the depth of maximum ionisation and the effective depth of the volume, irradiating the medium. The method for calculation of percentage depth dose at any point in the principal plane has been explained in detail. The simple form of the formulation will help in improving the treatment plans for treatments of lesions using Co-60 teletherapy machines. (orig.) [de

  19. The effects of Co60 gamma rays on the absorption of salicylic natrium orally given to white rats

    International Nuclear Information System (INIS)

    Wiharto, Kunto; Kamal, Zainul; Mulyanto; Muryono, H.

    1982-01-01

    The effects of Co 60 gamma rays on the absorption of salicylic natrium orally taken by white rats after being irradiated were studied. Patients treated with radiation used to be given analgesic drugs to elicit pain. Effects of radiation on the physiology of gastrointestinal tracts of such patients are to be studied. Based on this perception some white rats were irradiated with Co 60 gamma rays at the cumulative doses of 500, 750, and 1000 rads which were fractionated to 5 daily doses of 100, 150, and 200 rads. Salicylate concentration in the rat's blood was measured with spectrophotometer. It was found that the greater the radiation dose was given, the less salicylic natrium was absorbed and at a certain dose saturation point happened. (RUW)

  20. A comparison of 4 MeV Proton and Co-60 gamma irradiation induced degradation in the electrical characteristics of N-channel MOSFETs

    Energy Technology Data Exchange (ETDEWEB)

    Anjum, Arshiya; Vinayakprasanna, N.H.; Pradeep, T.M. [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570006 (India); Pushpa, N. [Department of PG Studies in Physics, JSS College, Ooty Road, Mysore 570025 (India); Krishna, J.B.M. [IUC-DAE CSR, Kolkota 700098 (India); Gnana Prakash, A.P., E-mail: gnanaprakash@physics.uni-mysore.ac.in [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570006 (India)

    2016-07-15

    N-channel depletion MOSFETs were irradiated with 4 MeV Proton and Co-60 gamma radiation in the dose range of 100 krad(Si) to 100 Mrad(Si). The electrical characteristics of MOSFET such as threshold voltage (V{sub th}), density of interface trapped charges (ΔN{sub it}), density of oxide trapped charges (ΔN{sub ot}), transconductance (g{sub m}), mobility (μ), leakage current (I{sub L}) and drain saturation current (I{sub D} {sub Sat}) were studied as a function of dose. A considerable increase in ΔN{sub it} and ΔN{sub ot} and decrease in V{sub th,}g{sub m}, μ, and I{sub D} {sub Sat} was observed after irradiation. The results of 4 MeV Proton irradiation were compared with that of Co-60 gamma radiation and it is found that the degradation is more for the devices irradiated with 4 MeV Protons when compared with the Co-60 gamma radiation. This indicates that Protons induce more trapped charges in the field oxide region when compared to the gamma radiation.

  1. Multistep process of neoplastic transformation of normal human fibroblasts by 60Co gamma rays and Harvey sarcoma viruses

    Energy Technology Data Exchange (ETDEWEB)

    Namba, M.; Nishitani, K.; Fukushima, F.; Kimoto, T.; Nose, K.

    1986-03-15

    As reported previously (Namba et al., 1985), normal human fibroblasts were transformed by 60Co gamma-ray irradiation into immortal cells with abnormal karyotypes. These transformed cells (KMST-6), however, showed a low cloning efficiency in soft agar and no transplantability. However, upon treatment with Harvey murine sarcoma virus (Ha-MSV), the cells acquired elevated clonability in soft agar and transplantability in nude mice. Ha-MSV alone, however, did not convert normal human fibroblasts into either immortal or tumorigenic cells. The Ha-MSV-transformed KMST-6 cells showed an enhanced expression of the ras oncogene, but normal and 60Co gamma-ray-transformed cells did not. Our current data suggest that gamma rays worked against normal human cells as an initiator, giving rise to chromosome aberrations and immortality, and that Ha-MSV, probably through its ras oncogene, played a role in the progression of the malignant cell population to a more malignant one showing enhanced colony formation in soft agar and tumorigenicity in nude mice.

  2. Electrical characteristics of {sup 60}Co {gamma}-ray irradiated MIS Schottky diodes

    Energy Technology Data Exchange (ETDEWEB)

    Tataroglu, A. [Department of Physics, Faculty of Arts and Sciences, Gazi University, 06500 Ankara (Turkey)]. E-mail: ademt@gazi.edu.tr; Altindal, S. [Department of Physics, Faculty of Arts and Sciences, Gazi University, 06500 Ankara (Turkey)

    2006-11-15

    In order to interpret the effect of {sup 60}Co {gamma}-ray irradiation dose on the electrical characteristics of MIS Schottky diodes, they were stressed with a zero bias at 1 MHz in dark and room temperature during {gamma}-ray irradiation and the total dose range was 0-450 kGy. The effect of {gamma}-ray exposure on the electrical characteristics of MIS Schottky diodes has been investigated using C-V and G/{omega}-V measurements at room temperature. Experimental results show that {gamma}-ray irradiation induces a decrease in the barrier height {phi} {sub B} and series resistance R {sub s}, decreasing with increasing dose rate. Also, the acceptor concentration N {sub A} increases with increasing radiation dose. The C-V characteristics prove that there is a reaction for extra recombination centers in case of MIS Schottky diodes exposed to {gamma}-ray radiation. Furthermore, the density of interface states N {sub ss} by Hill-Coleman method increases with increasing radiation dose. Experimental results indicate that the interface-trap formation at high irradiation dose is reduced due to positive charge build-up in the Si/SiO{sub 2} interface (due to the trapping of holes) that reduces the flow rate of subsequent holes and protons from the bulk of the insulator to the Si/SiO{sub 2} interface.

  3. The induction mutation effects of "6"0Co gamma radiation on physiological growth of tomato

    International Nuclear Information System (INIS)

    Gusti Ngurah Sutapa; I Gde Antha Kasmawan

    2016-01-01

    Almost all types of cuisine in Indonesia are using tomatoes as the base material of manufacture. The nutritional value contained in tomatoes is also quite high, because there is a number of vitamin content required by the human body. In addition, the tomatoes in plants featured national horticultural commodity and priority on a number of provinces in Indonesia. So many benefits of tomatoes indicates that the productivity of tomatoes should be improved. One improvement in terms of quality can be done by means of mutation induction with gamma radiation of Co-60. Induction of mutations are genetic changes caused by human effort, one of them is by using radioactive materials. Gamma rays of Co-60 from the IRPASENA facility was exposed to tomato seeds at doses of 50, 100, 150, 200 and 250 Gy. And then measurements were conducted on the physiological growth of leaf width, plant height, number of fruit and wet weight of tomatoes from week 1 until harvest. The results showed a growth curve of tomato is in accordance with sigmoidal plant physiological growth curve. Optimal physiological growth of tomato plants was obtained at dose of gamma radiation of 100 Gy. At this optimal dose physiological growth of tomato plants is the best (superior) than in doses below and above 100 Gy and control. (author)

  4. 60Co gamma radiation effect on AlGaN//AlN/GaN HEMT devices

    International Nuclear Information System (INIS)

    Wang Yanping; Luo Yinhong; Wang Wei; Zhang Keying; Guo Hongxia; Guo Xiaoqiang; Wang Yuanming

    2013-01-01

    The testing techniques and experimental methods of the 60 Co gamma irradiation effect on AlGaN/AlN/GaN high electron mobility transistors (HEMTs) are established. The degradation of the electrical properties of the device under the actual radiation environment are analyzed theoretically, and studies of the total dose effects of gamma radiation on AlGaN/AlN/GaN HEMTs at three different radiation bias conditions are carried out. The degradation patterns of the main parameters of the AlGaN/AlN/GaN HEMTs at different doses are then investigated, and the device parameters that were sensitive to the gamma radiation induced damage and the total dose level induced device damage are obtained. (authors)

  5. Comparative analysis of {sup 60}Co intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fox, Christopher [Sun Nuclear Corporation, 425-A Pineda Court, Melbourne, FL 32940 (United States); Romeijn, H Edwin; Lynch, Bart; Dempsey, James F [Department of Radiation Oncology, University of Florida, Gainesville, FL 32610-0385 (United States); Men, Chunhua [Department of Industrial and Systems Engineering, University of Florida, Gainesville, FL 32611-6595 (United States); Aleman, Dionne M [Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario (Canada)], E-mail: chrisfox@sunnuclear.com, E-mail: romeijn@ise.ufl.edu, E-mail: lynchb@ufl.edu, E-mail: chhmen@ufl.edu, E-mail: aleman@mie.utoronto.edu, E-mail: dempsey@ufl.edu

    2008-06-21

    In this study, we perform a scientific comparative analysis of using {sup 60}Co beams in intensity-modulated radiation therapy (IMRT). In particular, we evaluate the treatment plan quality obtained with (i) 6 MV, 18 MV and {sup 60}Co IMRT; (ii) different numbers of static multileaf collimator (MLC) delivered {sup 60}Co beams and (iii) a helical tomotherapy {sup 60}Co beam geometry. We employ a convex fluence map optimization (FMO) model, which allows for the comparison of plan quality between different beam energies and configurations for a given case. A total of 25 clinical patient cases that each contain volumetric CT studies, primary and secondary delineated targets, and contoured structures were studied: 5 head-and-neck (H and N), 5 prostate, 5 central nervous system (CNS), 5 breast and 5 lung cases. The DICOM plan data were anonymized and exported to the University of Florida optimized radiation therapy (UFORT) treatment planning system. The FMO problem was solved for each case for 5-71 equidistant beams as well as a helical geometry for H and N, prostate, CNS and lung cases, and for 3-7 equidistant beams in the upper hemisphere for breast cases, all with 6 MV, 18 MV and {sup 60}Co dose models. In all cases, 95% of the target volumes received at least the prescribed dose with clinical sparing criteria for critical organs being met for all structures that were not wholly or partially contained within the target volume. Improvements in critical organ sparing were found with an increasing number of equidistant {sup 60}Co beams, yet were marginal above 9 beams for H and N, prostate, CNS and lung. Breast cases produced similar plans for 3-7 beams. A helical {sup 60}Co beam geometry achieved similar plan quality as static plans with 11 equidistant {sup 60}Co beams. Furthermore, 18 MV plans were initially found not to provide the same target coverage as 6 MV and {sup 60}Co plans; however, adjusting the trade-offs in the optimization model allowed equivalent target

  6. Hypodontia in the beagle after perinatal whole-body 60Co gamma irradiation

    International Nuclear Information System (INIS)

    Lee, A.C.; Angleton, G.M.; Benjamin, S.A.

    1989-01-01

    As part of a long-term study to evaluate health effects of pre- and postnatal irradiation, dental development was examined. Beagles were irradiated in utero at 8, 28, or 55 days postcoitus or postnatally at 2, 70, or 365 days postpartum. Whole-body 60 Co gamma radiation doses ranged from 0 to 3.8 Gy. There was an age-dependent dose-related increase in premolar hypodontia for animals irradiated at 55 days postcoitus or 2 days postpartum with doses of 0.83 Gy or higher and for those irradiated at 28 days postcoitus with 1.2 Gy or higher

  7. Effect of 60Co-gamma radiation on the binding properties in furs

    International Nuclear Information System (INIS)

    Raina, R.K.

    1992-01-01

    New Zealand white rabbit pelts were pickled by the usual procedure and were tanned with basic aluminium sulphate, basic chromium sulphate and their combinations. Tanned furs were irradiated with 60 Co-gamma radiations in the dose range of 5.0-114.0 kGy. The effect of radiation on the binding properties of various added substances like mineral tannins, fats, moisture and shrinkage temperature has been assessed by their comparison with the control samples. The results of these investigations show that radiation on furs causes detannage, increases the moisture and bound fat content and decreases the shrinkage temperature of the furs. (author)

  8. Perna perna (LINNAEUS, 1758) mussels irradiated by 60CO gamma rays cytotoxicity evaluation

    International Nuclear Information System (INIS)

    Martini, Gisela A.; Pusceddu, Fabio H.; Rogero, Sizue O.; Rogero, Jose Roberto

    2013-01-01

    The aim of the present work was the study of ionizing radiation effects on aquatic biota regarding the location of nuclear facilities nearby coastal areas assuming the risk of leaks and nuclear accidents. Bivalve mollusks have been widely used in the monitoring of aquatic environment studies mainly for their sessile habit and pollutants bioconcentration ability. So marine mussel Perna perna (Bivalvia: Mytilidae) was used as organism test in this study. The study of radioactive toxicity was performed by cytotoxicity test exposing the organisms to 11Gy gamma radiation dose. After radiation the neutral red retention assay evaluated the lysosomal membrane integrity in the mussel hemocytes. 50% lethal dose assay (LD50) of gamma radiation on Perna perna mussels was carried out by exposure the organisms to 60 Co gamma rays at doses ranging from 0 to 3000 Gy. The result of gamma radiation LD50 for these mussels was 1068 Gy and the neutral red retention time of irradiated organisms was about 47% lower than the control, non irradiated organisms. With the obtained results is expected to contribute in the study to identify the range of ionizing radiation doses which can cause toxic effects in marine invertebrates. (author)

  9. Prototype system for proton beam range measurement based on gamma electron vertex imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Han Rim [Neutron Utilization Technology Division, Korea Atomic Energy Research Institute, 111, Daedeok-daero 989beon-gil, Yuseong-gu, Daejeon 34057 (Korea, Republic of); Kim, Sung Hun; Park, Jong Hoon [Department of Nuclear Engineering, Hanyang University, Seongdong-gu, Seoul 04763 (Korea, Republic of); Jung, Won Gyun [Heavy-ion Clinical Research Division, Korean Institute of Radiological & Medical Sciences, Seoul 01812 (Korea, Republic of); Lim, Hansang [Department of Electronics Convergence Engineering, Kwangwoon University, Seoul 01897 (Korea, Republic of); Kim, Chan Hyeong, E-mail: chkim@hanyang.ac.kr [Department of Nuclear Engineering, Hanyang University, Seongdong-gu, Seoul 04763 (Korea, Republic of)

    2017-06-11

    In proton therapy, for both therapeutic effectiveness and patient safety, it is very important to accurately measure the proton dose distribution, especially the range of the proton beam. For this purpose, recently we proposed a new imaging method named gamma electron vertex imaging (GEVI), in which the prompt gammas emitting from the nuclear reactions of the proton beam in the patient are converted to electrons, and then the converted electrons are tracked to determine the vertices of the prompt gammas, thereby producing a 2D image of the vertices. In the present study, we developed a prototype GEVI system, including dedicated signal processing and data acquisition systems, which consists of a beryllium plate (= electron converter) to convert the prompt gammas to electrons, two double-sided silicon strip detectors (= hodoscopes) to determine the trajectories of those converted electrons, and a plastic scintillation detector (= calorimeter) to measure their kinetic energies. The system uses triple coincidence logic and multiple energy windows to select only the events from prompt gammas. The detectors of the prototype GEVI system were evaluated for electronic noise level, energy resolution, and time resolution. Finally, the imaging capability of the GEVI system was tested by imaging a {sup 90}Sr beta source, a {sup 60}Co gamma source, and a 45-MeV proton beam in a PMMA phantom. The overall results of the present study generally show that the prototype GEVI system can image the vertices of the prompt gammas produced by the proton nuclear interactions.

  10. Qualities of Patin Fishball Irradiated by Gamma Rays (60Co)

    International Nuclear Information System (INIS)

    Yarosita FS; Bustami I; Winarti Z; Rindy PT

    2004-01-01

    An experiment on patin fishball quality using gamma irradiation ( 60 Co) has been conducted. Samples were irradiated at 0, 1, 3 and 5 kGy and stored in refrigerator at temperature 10 o C for sixty days. Samples were analysed every fifteen days, except content of fat and protein that analysed only at the beginning and the end of storage. The purpose of this experiment is to know the quality changes of patin fishball irradiated during storage, by measuring of chemical (content of fat, protein, water, TVB value, pH value) and microbiology (TPC aerobic and anaerobic bacteria) changes. The results showed that irradiation did not affect macro nutrient contents (content of fat, protein and water) of patin fishball during storage but irradiation can affect TVB and pH values. Irradiation at 1 kGy can reduce one logarithmic cycle of total aerobic and anaerobic bacteria. The storage life of irradiated patin fishball treated at 1, 3 and 5 kGy could be extended up to 15, 30 and 60 days, respectively. Control samples the storage life could be extended less than 15 days. (author)

  11. Effects of CO-60 gamma radiation on the embryonary development of Biomphalaria Glabrata (Say, 1818)

    International Nuclear Information System (INIS)

    Okazaki, K.

    1988-01-01

    Some aspects of the effects of the ionizing radiation on the embryo and on the genetical material of Biomphalaria glabrata (Mollusca: Gastropoda) are presented. The embryos weresubmitted at various stages of development to doses of 5,10,15,20 and 25 Gy of Co-60 gamma radiation. As a criteia of evaluation of the embryos radiosensitivity, four biological parameters were used: mortality, malformation, hatching and chromossomal aberrations. (M.A.C.) [pt

  12. Study of radiation detectors response in standard X, gamma and beta radiation standard beams

    International Nuclear Information System (INIS)

    Nonato, Fernanda Beatrice Conceicao

    2010-01-01

    The response of 76 Geiger-Mueller detectors, 4 semiconductor detectors and 34 ionization chambers were studied. Many of them were calibrated with gamma radiation beams ( 37 Cs and 60 Co), and some of them were tested in beta radiation ( 90 Sr+ 9' 0Y e 204 Tl) and X radiation (N-60, N-80, N-100, N-150) beams. For all three types of radiation, the calibration factors of the instruments were obtained, and the energy and angular dependences were studied. For beta and gamma radiation, the angular dependence was studied for incident radiation angles of 0 deg and +- 45 deg. The curves of the response of the instruments were obtained over an angle interval of 0 deg to +- 90 deg, for gamma, beta and X radiations. The calibration factors obtained for beta radiation were compared to those obtained for gamma radiation. For gamma radiation, 24 of the 66 tested Geiger-Mueller detectors presented results for the energy dependence according to international recommendation of ISO 4037-2 and 56 were in accordance with the Brazilian ABNT 10011 recommendation. The ionization chambers and semiconductors were in accordance to national and international recommendations. All instruments showed angular dependence less than 40%. For beta radiation, the instruments showed unsatisfactory results for the energy dependence and angular dependence. For X radiation, the ionization chambers presented results for energy dependence according to the national recommendation, and the angular dependence was less than 40%. (author)

  13. Studies of radiation gamma effects of 60 Co on fecundity, fertility and survival of Biomphalaria straminea (Dunker, 1848)

    International Nuclear Information System (INIS)

    Albuquerque Melo, Ana M.M. de; Motta, Mauricy A. da

    1997-01-01

    The effects of gamma 60 Co radiation on fecundity, fertility and survival of Biomphalaria straminea was carried out with these mollusks kept in totality reproductive isolation and grouped, for their possible utilization in the study of radiation effect in biological system. Biomphalaria straminea species are disseminated in Brazil, specially in Northeast region. The snails were exposed to the following doses of gamma radiation: 2.5; 5.0; 7.5; 10; 15; 20; 25; 30; 35; 40; 45; 55; 60; 80; 160; 320; and 640 gy source was a Gamma Cell Co model RL (rate dose = 0,31 Gy/min). The fecundity was observed through the count of the spawing abd eggs number/snail/day; the fecundity and fertility when the radiation dose increased; it was evidenced that the grouped mollusks presented a better performance in respectivity when compared with the isolated ones. After the statistical analysis was observed that fercundity and fertility were closely related. The survival, presented higher levels of resistence in isolated mollusks than in grouped ones. The DL50/30 obtained for the isolated mollusks submitted the radiation was about 90 Gy and for the grouped ones 70 Gy. (author). 29 refs., 3 figs., 2 tabs

  14. Effects of gamma radiation from 60Co on dilute aqueous solutions of Linear Alkyl Sulfonate Surfactants and other organic pollutants

    International Nuclear Information System (INIS)

    Rohrer, D.M.

    1975-01-01

    This study is the result of research findings and operational experiences gained by the author in over four years of work associated with the use of 60 Co for the treatment of waste-water. The effects of 60 Co are discussed with regard to radiochemical destruction of specific organic pollutant species. The study deals specifically with the effects of gamma radiation from a 30,000 Ci 60 Co source upon aqueous solutions of Linear Alkyl Sulfonate Surfactants. The new Linear Alkyl Sulfonate (LAS) Surfactants, the major surfactant produced in the United States of America since June 1965, was developed to replace the old Alkyl Benzene Sulfonate (ABS) Surfactants. The reason for the removal of Alkyl Benzene Sulfonate Surfactants was their extreme environmental stability and the associated appearance of foam in waste-water treatment plants and receiving streams. Although the Linear Alkyl Sulfonate Surfactants are considered 'bio-degradable', the time required for 'bio-degradation' is impractical within the present environmental guidelines. This led to research into alternate techniques of treatment for the destruction of Linear Alkyl Sulfonate Surfactants. Consideration is also given to similar effects of gamma radiation upon pesticides and to the practical aspects of the use of gamma radiation for the treatment of waste-water. Included are discussions of the general experimental procedures used, the sources and their calibration, and sampling techniques to ensure the accuracy of the data. (author)

  15. Effect of [sup 60]Co-gamma radiation on the binding properties in furs

    Energy Technology Data Exchange (ETDEWEB)

    Raina, R K [Regional Research Lab., Srinagar (India)

    1992-09-01

    New Zealand white rabbit pelts were pickled by the usual procedure and were tanned with basic aluminium sulphate, basic chromium sulphate and their combinations. Tanned furs were irradiated with [sup 60]Co-gamma radiations in the dose range of 5.0-114.0 kGy. The effect of radiation on the binding properties of various added substances like mineral tannins, fats, moisture and shrinkage temperature has been assessed by their comparison with the control samples. The results of these investigations show that radiation on furs causes detannage, increases the moisture and bound fat content and decreases the shrinkage temperature of the furs. (author).

  16. The role of {sup 60}Co gamma-ray irradiation on the interface states and series resistance in MIS structures

    Energy Technology Data Exchange (ETDEWEB)

    Tascioglu, Ilke [Department of Physics, Faculty of Science and Arts, Gazi University, 06500 Ankara (Turkey); Tataroglu, Adem, E-mail: ademt@gazi.edu.t [Department of Physics, Faculty of Science and Arts, Gazi University, 06500 Ankara (Turkey); Ozbay, Akif; Altindal, Semsettin [Department of Physics, Faculty of Science and Arts, Gazi University, 06500 Ankara (Turkey)

    2010-04-15

    The effect of gamma-ray exposure on the metal-insulator-semiconductor (MIS) structures has been investigated using the electrical characteristics at room temperature. The MIS structures are irradiated with {sup 60}Co gamma-ray source. The energy distribution of interface states was determined from the forward bias I-V characteristics by taking into account the bias dependence of the effective barrier height and ideality factor. The value of series resistance decreases with increasing dose. Experimental results confirmed that gamma-ray irradiation have a significant effect on electrical characteristics of MIS structures.

  17. Deep defect levels in standard and oxygen enriched silicon detectors before and after **6**0Co-gamma-irradiation

    CERN Document Server

    Stahl, J; Lindström, G; Pintilie, I

    2003-01-01

    Capacitance Deep Level Transient Spectroscopy (C-DLTS) measurements have been performed on standard and oxygen-doped silicon detectors manufactured from high-resistivity n-type float zone material with left angle bracket 111 right angle bracket and left angle bracket 100 right angle bracket orientation. Three different oxygen concentrations were achieved by the so-called diffusion oxygenated float zone (DOFZ) process initiated by the CERN-RD48 (ROSE) collaboration. Before the irradiation a material characterization has been performed. In contrast to radiation damage by neutrons or high- energy charged hadrons, were the bulk damage is dominated by a mixture of clusters and point defects, the bulk damage caused by **6**0Co-gamma-radiation is only due to the introduction of point defects. The dominant electrically active defects which have been detected after **6**0Co-gamma-irradiation by C-DLTS are the electron traps VO//i, C//iC//s, V//2( = /-), V //2(-/0) and the hole trap C//i O//i. The main difference betwe...

  18. Perna perna (LINNAEUS, 1758) mussels irradiated by {sup 60}CO gamma rays cytotoxicity evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Martini, Gisela A.; Pusceddu, Fabio H.; Rogero, Sizue O.; Rogero, Jose Roberto, E-mail: gisela.martini@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The aim of the present work was the study of ionizing radiation effects on aquatic biota regarding the location of nuclear facilities nearby coastal areas assuming the risk of leaks and nuclear accidents. Bivalve mollusks have been widely used in the monitoring of aquatic environment studies mainly for their sessile habit and pollutants bioconcentration ability. So marine mussel Perna perna (Bivalvia: Mytilidae) was used as organism test in this study. The study of radioactive toxicity was performed by cytotoxicity test exposing the organisms to 11Gy gamma radiation dose. After radiation the neutral red retention assay evaluated the lysosomal membrane integrity in the mussel hemocytes. 50% lethal dose assay (LD50) of gamma radiation on Perna perna mussels was carried out by exposure the organisms to {sup 60}Co gamma rays at doses ranging from 0 to 3000 Gy. The result of gamma radiation LD50 for these mussels was 1068 Gy and the neutral red retention time of irradiated organisms was about 47% lower than the control, non irradiated organisms. With the obtained results is expected to contribute in the study to identify the range of ionizing radiation doses which can cause toxic effects in marine invertebrates. (author)

  19. Displacement correction factor versus effective point of measurement in depth dose curve measurements at {sup 60}Co gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Bruna, A [Universidad Nacional, Cordoba (Argentina). Facultad de Matematica, Astronomia y Fisica; Velez, G R [Hospital San Roque, Cordoba (Argentina). Dept. de Radioterapia; Brunetto, M [Centro Medico Rivado Dean Funes, Cordoba (Argentina)

    1996-08-01

    The discrepancies in data sets of values of the Displacement Factor p{sub d} recommended by different codes of practices for calibration purpose still demand further investigation to clarify this point. In this paper, we propose an experimental method to determine the displacement factor for cylindrical ionization chambers (thimble chambers) in photon beams. Measurements of p{sub d} for several depths were performed for {sup 60}Co gamma rays. From these results we calculated the shift of the effective point of measurement (z-z{sub eff}) for different depths. The results obtained in this work shown: (a) there is no significant change in p{sub d} from 2 cm to 17 cm of depth in water; (b) the value of p{sub d} for a ion-chamber Farmer type (inner radius r = 3.15 cm) is p{sub d} 0.988; (c) the shift of the effective point of measurement has a smooth variation with depth; (d) the value of (z-z{sub eff}) at the recommended calibration depth for {sup 60}Co beams (5 cm) is 0.6r (with r: inner radius of the chamber). The result (b) confirms the value of p{sub d} suggested by the SEFM and NACP protocols and differs with that of the AAPM. The value obtained for (z - z{sub eff}) (d) is very closed to that recommended by the IAEA TRS-277. Finally, the results (a) and (c) suggest that it should be preferable to use the displacement factor instead of effective point of measurement to perform measurements of depth dose curves, since the use of z{sub eff} should take into account its dependence on depth. (author). 7 refs, 4 figs.

  20. Dosimetry of a gammabeam 650 60Co irradiator

    International Nuclear Information System (INIS)

    Escobedo, J.F.; Nascimento Filho, V.F.; Barros Ferraz, E.S. de

    1980-01-01

    Fricke and glass dosimetries allowed the determination of some basic irradiation of the γ source Gamma-beam 650, 29,080 Ci of 60 Co on April 1st., 1974 made by Atomic Energy of Canada Limited, in operation at CENA - Piracicaba, Sa o Paulo, Brazil. The number of radioactive capsules in each of the 12 exposure tubes, the uniformity of the activity related to each tube and the mean position of the set of capsules during exposition were determined. The exposure rate at the central point of the internal cavity relatively to the diameter formed by 12 active tubes, were experimentally determined by Fricke dosimetry. The results agreed with those indicated in the operation manual of the irradiator source. (Author) [pt

  1. Morphological and histological studies on freshwater prawn Macrobrachium rosenbergii (de man) irradiated with {sup 60}Co gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Stalin, A.; Broos, K.V. [P.G. and Research Department of Zoology, Jamal Mohamed College (Autonomous), Tiruchirappalli 620020, Tamil Nadu (India); Sadiq Bukhari, A., E-mail: abjmc@yahoo.in [P.G. and Research Department of Zoology, Jamal Mohamed College (Autonomous), Tiruchirappalli 620020, Tamil Nadu (India); Syed Mohamed, H.E. [P.G. and Research Department of Zoology, Jamal Mohamed College (Autonomous), Tiruchirappalli 620020, Tamil Nadu (India); Singhal, R.K. [Analytical Spectroscopy Section, Analytical Chemistry Division, Bhabha Atomic Research Center, Trombay, Mumbai 4000085 (India); Venu-Babu, P. [Nuclear Agriculture and Biotechnology Division, Bhabha Atomic Research Center, Trombay, Mumbai 4000085 (India)

    2013-11-15

    Graphical abstract: -- Highlights: •Analyzing the impact of {sup 60}Co gamma radiation (low doses) in M. rosenbergii. •LD{sub 50} identified in 30 Gy; Irradiated exhibits morphological changes than control. •Significantly decreased HSI and histological changes in irradiated groups. •Aberration severities increased as increased of dose level. •Biomonitoring tool in determining low dose radiation pollution in aquatic ecosystem. -- Abstract: This study was framed to investigate the {sup 60}Co gamma radiation induced morphological and histological variations in freshwater prawn Macrobrachium rosenbergii. The LD{sub 50} value of {sup 60}Co gamma irradiated M. rosenbergii observed (by probit analysis) at 30 Gy. Prawns were irradiated to four different dose levels (3 mGy, 30 mGy, 300 mGy and 3000 mGy) using Theratron Phoenix TeleCobalt Unit [P-33] and one control group (without irradiation) maintained separately. Irradiated groups exhibited several morphological variations such as discoloration; damaged rostrum; opaque coloration in cephalothorax; black bands and dot formation in abdomen; deformed uropods and telson in tail regions when compared with control group. The Hepato Somatic Index reflected the severity of radiation on hepatopancreas. Histological variations in gills, hepatopancreas and muscles of irradiated groups were observed. In gills, structural changes such as swollen and fused lamellae, abnormal gill tips, hyperplasic, necrotic and clavate-globate lamellae were observed in gamma irradiated prawns. Accumulation of hemocytes in hemocoelic space, interstitial sinuses filled with abnormal infiltrated hemocytes, the tubular epithelium with ruptured basal laminae, abnormal and coagulated lumen, necrotic tubules, thickened basal laminae, tissue debris, necrotic hepatocytes were observed in irradiated prawn hepatopancreas. In muscle, shrinkage of muscular fiber and necrotic musculature were observed in irradiated prawns. These structural alterations of

  2. TH-AB-BRA-02: Automated Triplet Beam Orientation Optimization for MRI-Guided Co-60 Radiotherapy

    International Nuclear Information System (INIS)

    Nguyen, D; Thomas, D; Cao, M; O’Connor, D; Lamb, J; Sheng, K

    2016-01-01

    Purpose: MRI guided Co-60 provides daily and intrafractional MRI soft tissue imaging for improved target tracking and adaptive radiotherapy. To remedy the low output limitation, the system uses three Co-60 sources at 120° apart, but using all three sources in planning is considerably unintuitive. We automate the beam orientation optimization using column generation, and then solve a novel fluence map optimization (FMO) problem while regularizing the number of MLC segments. Methods: Three patients—1 prostate (PRT), 1 lung (LNG), and 1 head-and-neck boost plan (H&NBoost)—were evaluated. The beamlet dose for 180 equally spaced coplanar beams under 0.35 T magnetic field was calculated using Monte Carlo. The 60 triplets were selected utilizing the column generation algorithm. The FMO problem was formulated using an L2-norm minimization with anisotropic total variation (TV) regularization term, which allows for control over the number of MLC segments. Our Fluence Regularized and Optimized Selection of Triplets (FROST) plans were compared against the clinical treatment plans (CLN) produced by an experienced dosimetrist. Results: The mean PTV D95, D98, and D99 differ by −0.02%, +0.12%, and +0.44% of the prescription dose between planning methods, showing same PTV dose coverage. The mean PTV homogeneity (D95/D5) was at 0.9360 (FROST) and 0.9356 (CLN). R50 decreased by 0.07 with FROST. On average, FROST reduced Dmax and Dmean of OARs by 6.56% and 5.86% of the prescription dose. The manual CLN planning required iterative trial and error runs which is very time consuming, while FROST required minimal human intervention. Conclusions: MRI guided Co-60 therapy needs the output of all sources yet suffers from unintuitive and laborious manual beam selection processes. Automated triplet orientation optimization is shown essential to overcome the difficulty and improves the dosimetry. A novel FMO with regularization provides additional controls over the number of MLC segments

  3. TH-AB-BRA-02: Automated Triplet Beam Orientation Optimization for MRI-Guided Co-60 Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, D; Thomas, D; Cao, M; O’Connor, D; Lamb, J; Sheng, K [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA (United States)

    2016-06-15

    Purpose: MRI guided Co-60 provides daily and intrafractional MRI soft tissue imaging for improved target tracking and adaptive radiotherapy. To remedy the low output limitation, the system uses three Co-60 sources at 120° apart, but using all three sources in planning is considerably unintuitive. We automate the beam orientation optimization using column generation, and then solve a novel fluence map optimization (FMO) problem while regularizing the number of MLC segments. Methods: Three patients—1 prostate (PRT), 1 lung (LNG), and 1 head-and-neck boost plan (H&NBoost)—were evaluated. The beamlet dose for 180 equally spaced coplanar beams under 0.35 T magnetic field was calculated using Monte Carlo. The 60 triplets were selected utilizing the column generation algorithm. The FMO problem was formulated using an L2-norm minimization with anisotropic total variation (TV) regularization term, which allows for control over the number of MLC segments. Our Fluence Regularized and Optimized Selection of Triplets (FROST) plans were compared against the clinical treatment plans (CLN) produced by an experienced dosimetrist. Results: The mean PTV D95, D98, and D99 differ by −0.02%, +0.12%, and +0.44% of the prescription dose between planning methods, showing same PTV dose coverage. The mean PTV homogeneity (D95/D5) was at 0.9360 (FROST) and 0.9356 (CLN). R50 decreased by 0.07 with FROST. On average, FROST reduced Dmax and Dmean of OARs by 6.56% and 5.86% of the prescription dose. The manual CLN planning required iterative trial and error runs which is very time consuming, while FROST required minimal human intervention. Conclusions: MRI guided Co-60 therapy needs the output of all sources yet suffers from unintuitive and laborious manual beam selection processes. Automated triplet orientation optimization is shown essential to overcome the difficulty and improves the dosimetry. A novel FMO with regularization provides additional controls over the number of MLC segments

  4. Influence of 60Co gamma radiation on fluorine plasma treated enhancement-mode high-electron-mobility transistor

    International Nuclear Information System (INIS)

    Quan Si; Hao Yue; Ma Xiao-Hua; Yu Hui-You

    2011-01-01

    AlGaN/GaN depletion-mode high-electron-mobility transistor (D-HEMT) and fluorine (F) plasma treated enhancement-mode high-electron-mobility transistor (E-HEMT) are exposed to 60 Co gamma radiation with a dose of 1.6 Mrad (Si). No degradation is observed in the performance of D-HEMT. However, the maximum transconductance of E-HEMT is increased after radiation. The 2DEG density and the mobility are calculated from the results of capacitance-voltage measurement. The electron mobility decreases after fluorine plasma treatment and recovers after radiation. Conductance measurements in a frequency range from 10 kHz to 1 MHz are used to characterize the trapping effects in the devices. A new type of trap is observed in the F plasma treated E-HEMT compared with the D-HEMT, but the density of the trap decreases by radiation. Fitting of G p /ω data yields the trap densities D T = (1 − 3) × 10 12 cm −2 · eV −1 and D T = (0.2 − 0.8) × 10 12 cm −2 · eV −1 before and after radiation, respectively. The time constant is 0.5 ms-6 ms. With F plasma treatment, the trap is introduced by etch damage and degrades the electronic mobility. After 60 Co gamma radiation, the etch damage decreases and the electron mobility is improved. The gamma radiation can recover the etch damage caused by F plasma treatment. (interdisciplinary physics and related areas of science and technology)

  5. Relative Biological Effectiveness of 14-MeV Fast Neutrons to Co{sup 60} Gamma-Rays in Einkorn Wheat; Efficacite Biologique Relative des Neutrons Rapides de 14 MeV par Rapport aux Rayons Gamma de {sup 60}Co sur l'Engrain; Otnositel'naya biologicheskaya ehffektivnost' bystrykh nejtronov s ehnergiej 14 MeV i gamma-luchej CO{sup 60} pri ikh dejstvii na pshenitsu odnozernyanku; EBR de los Neutrones Rapidos de 14 MeV y de los Rayos Gamma del {sup 60}Co en el Trigo Escanda Menor

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, T. [National Institute of Genetics, Misima (Japan)

    1964-05-15

    The author investigated the RBE of 14 MeV neutrons to Co{sup 60} gamma-rays by using the specific locus method in Einkorn wheat. F{sub 1} seeds from the cross between the original strain and a chlorina mutant were used in this study (chlorina mutant was obtained as a single recessive mutant from X-irradiation; it was uniformly light green from seedling stage to maturity with relatively high survival rate and fertility). The F{sub 1} plants showed normal green colour and normal growth habit. Dormant F{sub 1} seeds were irradiated at 0.5 , 1.0 and 1.4 krad of fast neutrons ami 4.3 , 8.6 and 12.9 krad of gamma-rays. Mutations from dominant normal green to chlorina occurred by both irradiations and appeared in the leaves and stems of the heterozygotic Xi plants as longitudinal stripes. Around 80% of seeds germinated in the control lot and in the lowest dosage lots from both neutron and gamma-ray irradiations, and germination percentages were gradually decreased with increasing dosage of both kinds of radiation. Moreover, a similar tendency was observed at the early stage as to seedling growth which was gradually inhibited with increasing dosage. According to these results, neutron irradiation was about 13 times more effective than that of gamma-rays. Survival rate in the non-irradiated control was about 90% and about 60-80% of germinated seedlings survived in 0.5 and 1.0 krad lots from neutron irradiation and all lots irradiated by gamma-rays. On the other hand, only about 4% of germinated seedlings survived in the highest neutron lot. No mutation was observed in the control lot, and the number of plants which contained striped tillers increased with increasing dosage of both kinds of radiation. Mutated tillers were observed in about 15% of surviving plants obtained at the lowest dosage of neutron irradiation and a similar frequency was observed from the highest dosage of gamma-rays. RBE of 14 MeV neutrons to Co{sup 60} gamma-rays seemed to be at least 20 for the

  6. Gamma radiation (Co60) effects on active substances and microbe burden of medicinal plants

    International Nuclear Information System (INIS)

    Dall'Agnol, L.

    2001-01-01

    In order to evaluate the effects of radioactivity on active vegetal substances, samples of Fennel (Foeniculum vulgare Miller., fructus), Guarana (Paulinia cupana, Kunth, semen), Gingko (gingko biloba, L., folium), and Kawa-Kawa (Piper methysticum G. Forst, rhizoma), were treated with scaling doses (0 to 25 KGy) of gamma radiation (Co 60 ). The 'blind test' methodology was used. The active substances from each sample were analysed by qualitative and quantitative methods after radiation. There were no significant differences seen between the control sample (0 KGy) and the irradiated samples. Microbe contamination was significantly reduced, about 10000 CFU/g, with the initial 5 KGy dose. It was concluded that gamma radiation can be used as an alternative procedure to reduce microbiologic contamination in medicinal plants. Before this procedure can be extended to other medicinal plants, more specific analytical methods are recommended to verify possible structural alterations in active vegetal molecules. (author)

  7. Micronuclei induced by fast neutrons versus 60Co gamma-rays in human peripheral blood lymphocytes.

    Science.gov (United States)

    Vral, A; Verhaegen, F; Thierens, H; De Ridder, L

    1994-03-01

    Here we compared the effectiveness of neutrons ( = 5.5 MeV) versus 60Co gamma-rays in producing micronuclei (MN) in human lymphocytes. To obtain dose-response data, blood samples of six donors were irradiated with doses ranging from 0.1 to 5 Gy for gamma-rays and 0.1-3 Gy for neutrons. A linear dependence of MN yield with dose was found for fast neutrons while for gamma-rays a nonlinear dependence existed. For both radiation qualities no significant interindividual differences were found. Derived relative biological effectiveness values decreased with increasing dose. The MN frequency distributions were overdispersed with respect to the Poisson distribution, with neutrons showing higher dispersion values than with gamma-rays. To compare the repair kinetics of both radiation qualities split-dose experiments were performed. A dose of 4 Gy gamma-rays (3 Gy neutrons) was delivered either as a single exposure or in two equal fractions separated by time intervals ranging from 30 min to 10 h (30 min to 7 h for neutrons). The data showed for gamma-rays a significant decline (30% +/- 10%) in MN yield with interfraction time due to repair of DNA damage. This repair is a continuous process starting almost immediately after the first of the two doses and lasting 3-5 h. For fast neutrons no decline was observed indicating irreparable damage.

  8. Acción protectora de la melatonina sobre células mononucleares de sangre periférica humana sometidas a radiación gamma Co60

    Directory of Open Access Journals (Sweden)

    Martha Mesa-Villanueva

    2009-04-01

    Full Text Available Protective action of melatonin on human peripheral blood mononuclear cells exposed to gamma radiation Co60. Objective: toevaluate the protective effect of melatonin on peripheral blood mononuclear cells (PBMCs exposed in vitro to ionizing radiation. Materialsand methods: PBMCs drawn from healthy volunteers were incubated with 0, 1x10-5, 1x10-6 y 1x10-7 M melatonin for 10 minutes beforebeing exposed to gamma radiation (300 cGy; Co60 source. Afterwards, DNA damage was evaluated with the comet assay. Results:PBMCs pretreated with melatonin showed comet tails shorter than those without the hormone treatment, as well as a lower percentage ofcells with severe DNA damage. Conclusion: melatonin doses of 1x10-5, 1x10-6 and 1x10-7 M provide in vitro protection to PBMCs fromDNA damage (single strand breaks and alkali-labile sites induced by gamma radiation (300 cGy; Co60 source.

  9. Target size analysis of bioactive substances by radiation inactivation. Comparison with electron beam and. gamma. -ray

    Energy Technology Data Exchange (ETDEWEB)

    Kume, Tamikazu; Watanabe, Yuhei; Ishigaki, Isao; Hirose, Shigehisa

    1988-11-01

    The molecular sizes of various bioactive substances can be measured by the radiation inactivation method. The high energy electron beam (10 MeV) and /sup 60/Co-..gamma.. ray are mainly used for radiation inactivation method. When the practical electron accelerator (/similar to/ 3 MeV) is used for the method, the problems such as penetration and increase of temperature will arise. In this paper the radiation inactivation using 3MeV electron beam is investigated by comparison with ..gamma..-ray. When the plate type glass ampules (glass thickness 1 +- 0.1 mm) were used as the irradiation vessels, relatively uniform dose distribution was obtained. The temperature increased only from 21 degC to 35 degC by irradiation (0.77 mA, 100 passes, 100 kGy). Under the irradiation condition mentioned above, the molecular size of three enzymes were calculated from D/sub 37/ doses. The molecular sizes obtained by electron beam and ..gamma..-ray were 14,000 and 17,000 respectively for lysozyme, 33,000 for pepsin, and 191,000 and 164,000 for yeast alcohol dehydrogenase. These values agreed closely with the reported molecular weight, suggesting that the 3 MeV electron beam can also be used for the radiation inactivation under limited conditions.

  10. Re-establishment of the air kerma and ambient dose equivalent standards for the BIPM protection-level 60Co beam

    International Nuclear Information System (INIS)

    Kessler, C.; Roger, P.

    2005-07-01

    The air kerma and ambient dose equivalent standards for the protection-level 60 Co beam have been re-established following the repositioning of the irradiator and modifications to the beam. Details concerning the standards and the new uncertainty budgets are described in this report with their implications for dosimetry comparisons and calibrations. (authors)

  11. Study on the energy dependence of gamma radiation detectors for {sup 137}Cs and {sup 60}Co; Estudo da dependencia energetica de detectores de radiacao gama para {sup 137}Cs e {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Nonato, Fernanda B.C.; Diniz, Raphael E.; Carvalho, Valdir S.; Vivolo, Vitor; Caldas, Linda V.E., E-mail: fbnonato@ipen.b, E-mail: rediniz@ipen.b, E-mail: vcsouza@ipen.b, E-mail: vivolo@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    38 Geiger-Mueller radiation detectors and 9 ionization chambers were calibrated, viewing to study the energy dependence of the monitor response for gamma radiation fields ({sup 137}Cs and {sup 60}Co). The results were considered satisfactory only for ionization chambers and for some Geiger-Mueller detectors

  12. Influence of beta radiation from tritium and gamma radiation from 60Co on the biological half-times of organically bound tritium

    International Nuclear Information System (INIS)

    Radwan, I.

    1981-01-01

    The influence of beta radiation from tritium on the biological half-times of organically bound tritium in particular tissues of the rat is compred with the influence of fractionated gamma radiation from 60 Co. (M.F.W.)

  13. Measurement of high dose rates of 60Co by gamma activation of115In and 111Cd foils

    International Nuclear Information System (INIS)

    Haddad, Kh; Qattan, M.; Taleb, A.

    2009-12-01

    The high gamma dose rate measurement technique using nuclear reaction (γ,(γ ' ') was introduced in this work. This technique is cheap, easy, reliable, and independent of chemical and physical factors, which affect other techniques. The response to the absorbed dose in this technique is linear and can be used for high dose. Cd and In foils were irradiated using 60 Co source and the resulted isomer activities were measured using gamma spectrometer. These foils were calibrated to be used as dosemeter and its results were compared with conventional one. The dose distribution in the irradiation field was determined using In foils. (authors)

  14. Use of 60Co gamma radiation in increased levels of total polyphenol extracts of bark of Schinus terebinthifolius Raddi

    International Nuclear Information System (INIS)

    Santos, Gustavo H.F.; Silva, Edvane B.; Silva, Hianna A.M.F.; Amorin, Elba L.C.; Peixoto, Tadeu J.S.; Yara, Ricardo; Lima, Claudia S.A.

    2013-01-01

    Schinus terebinthifolius Raddi (Anacardiaceae) is well known as sources of phenolic compounds. Known as mastic pepper, red pepper tree is a plant native to midsize coast of Brazil. Some of its structures have proven antibacterial, anti-inflammatory, antifungal and healing. The aim of this study was to evaluate the difference in the phenol contents of crude extracts that were measured after irradiating the barks of S. terebinthifolius using gamma radiation from 60 Co. The crude extract were divided into a control group and eight experimental groups, which were separated based on the doses of gamma radiation to which they were exposed: 2.5, 5.0, 7.5, 10.0, 12.5, 15.0, 20.0 and 50.0 kGy (Assays were performed in triplicate). The results allow observe that gamma radiation promoted in extracts of bark of S. terebinthifolius, many percents increase (p> 0.05) of total polyphenol content between 2.5 kGy (41.93%) and 50.0 kGy (44.52%) compared to 0 kGy (30.07%), with the same gradual to 10.0 kGy, and reaching peak maximum at 10.0 kGy (68.44%). However, the study puts the process of gamma radiation from 60 Co as an alternative significant increase in the percentage of some natural substances of plant material, and subsequently contribute to the augmentation of various therapeutic applications to which they are assigned. (author)

  15. Synthesis of gold nano particles with enlargement size by gamma Co-60 irradiation and investigation of anti oxidation effect

    International Nuclear Information System (INIS)

    Nguyen Ngoc Duy; Dang Van Phu; Le Anh Quoc; Nguyen Quoc Hien

    2014-01-01

    Gold nanoparticles (AuNPs) with size in the range of 10-53 nm were synthesized by gamma Co-60 irradiation using water-soluble chitosan (WSC) as stabilizer and size enlargement by seed approach. Absorption wavelength (λ max ) was measured by UV-Vis spectroscopy and particle size was determined from TEM images. Results showed that value of λ max increased from 523 nm (seed particles) to 525, 537 and 549 nm and the size of AuNPs increased from 10 nm (seed particles) to 20, 38 and 53 nm, respectively, for concentration ratio of Au 3+ /Au 0 (seed) of 2.5, 5 and 10. Antioxidant effect of AuNPs with size of 10, 20, 38 and 53 nm was investigated using free radical 2, 2'-azino-bis (3-ethylbenzothiazoline-6-sulphonic acid) (ABTS .+ ). Results indicated that the smaller the particle size was (10 nm) the stronger the antioxidant effect attained. Thus, AuNPs/WSC synthesis by gamma Co-60 irradiation are promising for applications as antioxidants in cosmetics and in other fields as well. (author)

  16. Teratogenic effects of 60Co gamma rays irradiation on rat embryos

    International Nuclear Information System (INIS)

    Lee, Juing-Yi; Okuda, Hiroe; Tutimoto, Sigeo; Satow, Yukio

    1987-01-01

    The teratogenicity of 60 Co gamma rays was evaluated in Donryu rats. The results were compared with those of triterated water (HTO) for determining relative biological effectiveness (RBE) for incidence of malformations and LD 50 in rats. Pregnant rats were irradiated with a 60 Co source at a dose-rate of 0.5 Gy/min or 0.01 Gy/min on day 7, 8, 9, 10 or 11 of gestation with 0.8, 1.0, 1.2, 1.5, 2.0, 2.3, 2.5, 2.8 or 3.0 Gy. HTO was administered intraperitoneal injection to pregnant rats at various doses on day 7, 8, 9, 10 and 11 of gestation. The rats were sacrificed on day 18 and the offspring were examined for external and visceral malformations. Mortality, teratogenicity and effects on fetal growth were day-and dosage-dependent in both radiation groups. Congenital malformations were found most frequently in the 9-day irradiated group and followed by the 8, 11, 10 and 7-day irradiated groups. The incidence of cardiovascular anomalies was highest, especially in the day 9 of gestation group, followed by malformations in the central nervous system, craniofacial system, respiratory system, hind limbs and tail. Beta rays from HTO were found to be more effective than γ rays in inducing congenital malformations. The RBE for incidence of malformations and LD 50 was between 1.3 and 1.5. These studies suggest that simulator of tritium irradiation is urgently needed to investigate the biological effects on rats to estimate the human risks, with respect to RBE of tritium beta rays. (author)

  17. Effect of low doses of gamma radiation of Co-60 (radio-hormesis) in tomato seeds

    International Nuclear Information System (INIS)

    Wiendl, Toni Andreas

    2010-01-01

    Tomato seeds of the Gladiador hybrid were exposed to gamma radiation of Co-60 with the following doses: 0; 2,5; 5; 7,5; 10; 12,5; 15 e 20 Gy. Analysis were performed on germination, seedlings height to cotyledon, seedling total height, seedling fresh and dry weight, plant height, stalk diameter at the root beginning, fresh and dry weight of the 5 th leaf, number of green fruits with diameter higher than 3 cm, number of green, half ripen and ripen fruits, total number of fruits, Brix and pH of fruits, average fruit weight and fruit total production. A variety of stimulation effects were observed on the different plant developing stages. The greatest stimulus for production was observed in the 10 Gy dose. The highest seedling average height and plant average height were observed for the 7,5 Gy dose. The biggest number of green fruits with diameter higher than 3 cm occurred for the 12,5 and 15 Gy treatments. Irradiation also stimulated a higher total number of fruits in all doses, having advantage the 10 Gy dose which produced 88% more fruits than control as well as 86% more weight production. The fruits pH acidified significantly in a dose of 12,5 Gy and higher. Production increased in all treatments comparing to control and the highest stimulus for production observed was for the 10, 12,5 and 15 Gy. The use of low gamma radiation doses of Co-60 applied as pre-sowing treatment in the seeds, efficiently stimulated the development of plants and the tomato production. (author)

  18. Effect of low-dose 60Co gamma irradiation on the photosynthetic activity of maize seedlings

    International Nuclear Information System (INIS)

    Turcsanyi, G.

    1979-01-01

    Photosynthesis investigations were carried out on maize seedlings treated with 1000 rad of 60 Co gamma irradiation prior to sowing. The aim of the work was to find out, to what degree the individual processes of photosynthesis are affected by small doses of irradiation. The increase in weight, the chlorophyll a, chlorophyll b and carotinoid content as well as the photosynthetic O 2 -evolution and 14 CO 2 -fixation of the seedlings were measured. The results indicate that, in contradiction to the data given in the literature, the occasional increase in weight caused by small-dose irradiation is not in connection with the membrane-bound part of the photosynthetic apparatus, but it is the consequence of the increased activity of the Calvin-cycle enzymes in the stroma of the chloroplasts. (author)

  19. DNA double-strand break and apoptosis induction in human lymphocytes in different cycle cell phases by 60Co gamma rays and Bragg peak protons of a medical beam

    International Nuclear Information System (INIS)

    Khachenkova, A.A.; Boreyko, A.V.; Mozhaeva, A.V.; Chausov, V.N.; Ravnachka, I.I.; Amov, I.; Tiunchik, S.I.

    2009-01-01

    A comparative analysis is made of the regularities in the formation of DNA double-strand break and apoptosis induction in peripheral human blood lymphocytes in different cell cycle phases after 60 Co gamma and extended Bragg peak proton irradiation. It is shown that the formation of apoptotic cells in a lymphocyte population increases linearly in all the cell cycle stages after proton irradiation. The maximal DNA double-strand break and apoptosis yield in lymphocytes is observed in the S phase of the cell cycle

  20. Comparisons of the standards for air kerma of the PTB and the BIPM for 60Co and 137Cs gamma radiation

    International Nuclear Information System (INIS)

    Allisy-Roberts, P.J.; Burns, D.T.; Buermann, L.; Kramer, H.M.

    2005-11-01

    Direct comparisons of the standards for air kerma of the Physikalisch-Technische Bundesanstalt (PTB, Germany) and of the Bureau International des Poids et Mesures (BIPM) were carried out in the 60 Co and 137 Cs radiation beams of the BIPM in 2000. The results, expressed as ratios of the PTB and the BIPM standards for air kerma, indicate a relative difference in 60 Co of 9.9 x 10 -3 with a combined standard uncertainty of 1.8 x 10 -3 , and in 137 Cs of 6.4 x 10 -3 with a combined standard uncertainty of 2.8 x 10 -3 . The earlier comparisons in 60 Co γ rays made in 1971 (direct) and 1989 (indirect) resulted in an agreement of the two standards within 2 x 10 -3 . The differences obtained now are due to the application of new correction factors for wall effects and point source non-uniformity of the beam, k wall and k pn , for the PTB standards, which were calculated using Monte Carlo methods. (authors)

  1. Use of {sup 60}Co gamma radiation in increased levels of total polyphenol extracts of bark of Schinus terebinthifolius Raddi

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Gustavo H.F.; Silva, Edvane B.; Silva, Hianna A.M.F.; Amorin, Elba L.C.; Peixoto, Tadeu J.S.; Yara, Ricardo; Lima, Claudia S.A., E-mail: santosghf@hotmail.com, E-mail: edvborges@yahoo.com, E-mail: amdemelo@hotmail.com, E-mail: claudia.salima@gmail.com, E-mail: ricardo.yara@gmail.com, E-mail: tadeu1903@yahoo.com.br, E-mail: elba@ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2013-07-01

    Schinus terebinthifolius Raddi (Anacardiaceae) is well known as sources of phenolic compounds. Known as mastic pepper, red pepper tree is a plant native to midsize coast of Brazil. Some of its structures have proven antibacterial, anti-inflammatory, antifungal and healing. The aim of this study was to evaluate the difference in the phenol contents of crude extracts that were measured after irradiating the barks of S. terebinthifolius using gamma radiation from {sup 60}Co. The crude extract were divided into a control group and eight experimental groups, which were separated based on the doses of gamma radiation to which they were exposed: 2.5, 5.0, 7.5, 10.0, 12.5, 15.0, 20.0 and 50.0 kGy (Assays were performed in triplicate). The results allow observe that gamma radiation promoted in extracts of bark of S. terebinthifolius, many percents increase (p> 0.05) of total polyphenol content between 2.5 kGy (41.93%) and 50.0 kGy (44.52%) compared to 0 kGy (30.07%), with the same gradual to 10.0 kGy, and reaching peak maximum at 10.0 kGy (68.44%). However, the study puts the process of gamma radiation from {sup 60}Co as an alternative significant increase in the percentage of some natural substances of plant material, and subsequently contribute to the augmentation of various therapeutic applications to which they are assigned. (author)

  2. Responses of diode detectors to radiation beams from teletherapy machines

    International Nuclear Information System (INIS)

    Malinda, Lora; Nasukha

    2003-01-01

    Responses of diode detectors to radiation beams from teletherapy machines. It has been carried out responses to two sets of diode detector by using the beams of teletherapy Co-60 and medical linear accelerator. Each set of consist of 8 diode detectors was irradiated by using gamma beams from teletherapy Co-60 machines and 6 MV and 10 MV foron beams from medical linear accelerator and 6.9.12.16. and 20 MeV electron beams from medical linear accelerator. The detectors were positioned on the phantom circularly and radially and electronic equilibrium condition for all type and energy beams. It was found that every detectors had own individual response and it is not to be uniformity, since the fluctuation in between 16.6 % to 30.9 %. All detectors responses are linear to gamma and foron beams, and also for energy above 6 MeV for electron beams. Nonlinearity response occurs for 6 MeV electron beam, it is probably from the assumption of electronic equilibrium

  3. Biochemical and pharmacological studies of native and irradiated crotamine with gamma radiation of 60Co

    International Nuclear Information System (INIS)

    Mitake, Malvina Boni

    2000-01-01

    Ionizing radiation can change the molecular structure and affect the biological properties of biomolecules. This has been employed to attenuate animal toxins. Crotamine is a strongly basic polypeptide from the South American rattlesnake venom, composed of 42 amino acid residues. It induces skeletal muscle spasms leading to a spastic paralysis of hind limbs in mice. The objective of this thesis was carry out biochemical and pharmacological studies of native and irradiated crotamine with 60 Co. Crotamine was purified from Crotalus durissus terrificus venom by Sephadex G-100 gel filtration followed by ion exchange chromatography, using a Fast Performance Liquid Chromatography (FPLC) system. It was irradiated at 2 mg/ml in 0.15 M Na Cl with 2.0 kGy gamma radiation emitted by a 60 Co source. The native and irradiated crotamine were evaluated by biochemical characterization, toxic activity (LD 50 and biodistribution. The native and irradiated crotamine were labelled with 29.6 MBq of 125 I using chloramine T method, and separated in a Sephadex G-50 column. Male Swiss mice (35± 5 g), were injected i.p. with o.1 mL (2.4 x 10 6 cpm/mouse) of 125 I native crotamine or with 0.4 mL (1.3 x 10 6 cpm/mouse) of 125 I irradiated crotamine. At 0.08; 0.25; 0.5; 1; 2; 4; 8; 12 and 24 hours the animal were killed by ether inhalation. Blood, spleen, liver, kidneys, brain, lungs, heart, and skeletal muscle were collected in order to determine radioactivity content. The results showed that gamma radiation did not change the protein concentration, the electroforetic profile or the primary structure of the protein, although differences were shown by spectroscopic techniques. The gamma radiation diminished the toxicity of crotamine, but it did not abolish bioactivity. Biodistribution studies showed that native and irradiated crotamine have hepatic metabolism and renal elimination. The native and irradiated crotamine have affinity by skeletal muscle and they did not pass the blood - brain

  4. Elimination of N-nitrosamines and their precusors in some foods by /sup 60/Co. gamma. -ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Jifan, Hu; Yingqiang, He; Puju, Song

    1987-10-01

    N-Dimethylnitrosamine (NDMA) in some marine foods, such as dried shrimp, fish meal and salted fish, was drastically reduced by ..gamma..-ray irradiation with /sup 60/Co. The shrimp contained 54.6 ppb NDMA, but only 29.3, 8.8, 11.4, and 1.9 ppb were detected after irradiation with doses of 5, 10, 15 and 20 kGy. The corresponding reduction was 46.3%, 83.9%, 79.1%, and 96.6%, respectively. Similar results were also obtained in other two kinds of foods. NDMA could be completely eliminated by the irradiation in aqueous solution, which was much more markable than that in food samples. The major irradiated products of NDMA were dimethylamine and nitrous acid, but no re-formation of nitrosamines took place. /sup 60/Co irradiation also significantly decreased the content of nitrite in salted fish and in aqueous solution. No effect on nitrate could be observed.

  5. Verification of Treatment Planning System (TPS) on Beam Axis of Co-60 Teletherapy

    International Nuclear Information System (INIS)

    Nunung-Nuraeni; Budhy-Kurniawan; Purwanto; Sugiyantari; Heru-Prasetio; Nasukha

    2001-01-01

    Cancer diseases up to now can be able to be treated by using surgery, chemotherapy and radiotherapy. The need of high level precision and accuracy on radiation dose are very important task. One of task is verification of Treatment Planning System (Tps) to the treatment of patients. The research has been done to verify Tps on beam exis of teletherapy Co-60. Result found that the different between Tps and measurements are about -2.682 % to 1.918% for simple geometry and homogeneous material, 5.278 % to 4.990 % for complex geometry, and -3.202 % to -2.090 % for more complex geometry. (author)

  6. The development of 60Co γ knife therapy sources

    International Nuclear Information System (INIS)

    Wu Rihua; Li Xingyi; Wu Guihua; Xia Bing; Zhang Jirong; Chen Tieguang

    2001-01-01

    60 Co γ gamma knife source is a kernel unit of γ knife therapy equipment. It has small active core, high specific activity, narrow half dark area, best focus form, long use period. The research of 60 Co γ knife sources are presented. Specifications of γ knife sources, technical parameters, safety performance, structure feature, procedure and quality control during research are discussed. 60 Co γ source consists of high specific activity cobalt pellets and double stainless steel sealed by argon arc welding. Its safety performance, surface contamination and leakage testing meet the requirements of GB 4075 and GB 4076

  7. Morphological and histological studies on freshwater prawn Macrobrachium rosenbergii (de man) irradiated with (60)Co gamma radiation.

    Science.gov (United States)

    Stalin, A; Broos, K V; Sadiq Bukhari, A; Syed Mohamed, H E; Singhal, R K; Venu-Babu, P

    2013-11-15

    This study was framed to investigate the (60)Co gamma radiation induced morphological and histological variations in freshwater prawn Macrobrachium rosenbergii. The LD50 value of (60)Co gamma irradiated M. rosenbergii observed (by probit analysis) at 30 Gy. Prawns were irradiated to four different dose levels (3 mGy, 30 mGy, 300 mGy and 3,000 mGy) using Theratron Phoenix TeleCobalt Unit [P-33] and one control group (without irradiation) maintained separately. Irradiated groups exhibited several morphological variations such as discoloration; damaged rostrum; opaque coloration in cephalothorax; black bands and dot formation in abdomen; deformed uropods and telson in tail regions when compared with control group. The Hepato Somatic Index reflected the severity of radiation on hepatopancreas. Histological variations in gills, hepatopancreas and muscles of irradiated groups were observed. In gills, structural changes such as swollen and fused lamellae, abnormal gill tips, hyperplasic, necrotic and clavate-globate lamellae were observed in gamma irradiated prawns. Accumulation of hemocytes in hemocoelic space, interstitial sinuses filled with abnormal infiltrated hemocytes, the tubular epithelium with ruptured basal laminae, abnormal and coagulated lumen, necrotic tubules, thickened basal laminae, tissue debris, necrotic hepatocytes were observed in irradiated prawn hepatopancreas. In muscle, shrinkage of muscular fiber and necrotic musculature were observed in irradiated prawns. These structural alterations of the organs it is felt could affect the vital physiological functions such as respiration, osmotic and ionic regulation in gills and muscles; absorption, storage and secretion of the hepatopancreas which in turn could adversely affect the growth and survival of freshwater prawn M. rosenbergii. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Comparative effects of 60Co gamma-rays and neon and helium ions on cycle duration and division probability of EMT 6 cells. A time-lapse cinematography study.

    Science.gov (United States)

    Collyn-d'Hooghe, M; Hemon, D; Gilet, R; Curtis, S B; Valleron, A J; Malaise, E P

    1981-03-01

    Exponentially growing cultures of EMT 6 cells were irradiated in vitro with neon ions, helium ions or 60Co gamma-rays. Time-lapse cinematography allowed the determination, for individual cells, of cycle duration, success of the mitotic division and the age of the cell at the moment of irradiation. Irradiation induced a significant mitotic delay increasing proportionally with the delivered dose. Using mitotic delay as an endpoint, the r.b.e. for neon ions with respect to 60Co gamma-rays was 3.3 +/- 0.2 while for helium ions it was 1.2 +/- 0.1. Mitotic delay was greatest in those cells that had progressed furthest in their cycle at the time of irradiation. No significant mitotic delay was observed in the post-irradiation generation. Division probability was significantly reduced by irradiation both in the irradiated and in the post-irradiated generation. The reduction in division probability obtained with 3 Gy of neon ions was similar to that obtained after irradiation with 6 Gy of helium ions or 60Co gamma-rays.

  9. Effect of 60Co gamma-ray irradiation on dilute aqueous solutions of surfactants

    International Nuclear Information System (INIS)

    Sawai, Teruko; Shimokawa, Toshinari; Miki, Yasushi; Oseko, Koichi; Sawai, Takeshi

    1978-01-01

    Present work deals with the effects of gamma irradiation from 60 Co γ-ray source upon aqueous solutions of three kinds of surfactants. When dilute aqueous solutions of sodium dodecyl sulfate (SDS, anionic), cethyl trimethyl ammonium chloride (CTAC, cationic), and polyoxyethylene lauryl ether (POE, non-ionic) were irradiated with γ-rays at a room temperature, the residual concentration, products, surface tension, and forming power were examined by colorimetric method, IR spectrophotometric method, gaschromatography, Ross-Miles method, and Traube's stalagmometer etc. These surfactants were decomposed by the irradiation and thus the surface tension increased and the forming power, on the contrary, decreased with dose. Radiation chemical yields (G-value) of the degradation were about 1 for the solutions of SDS and CTAC, and about 0.3 for the POE solution. From the experimental results, it was found that following chemical reactions seem to occur followed by the radiolysis of water: a) bond cleavage of ester for SDS, of CN for CTAC, and of oxyethylene for POE, b) hydrogen abstraction from the surfactants, c) production of CO bond in the presence of dissolved oxygen. (auth.)

  10. Mechanical Property Of Zeolite-PVA Composite Mixture Irradiated By Gamma Ray Of Co-60

    International Nuclear Information System (INIS)

    Darsono; Danu, Sugiarto; Las, Tamzil

    2000-01-01

    Experiment on preparation of zeolite-polyvinyl alcohol composite for absorbance materials have been done by curring using Gamma γ-ray of Co-60. Zeolite with the particles size of 60 mesh was mixed with polyvinyl alcohol (PVA) at the concentration of the mixture were 6,9, and 12% by weight, than they were poured into glass tube (length = 100 mm; diameter = 10 mm) and irradiated at the doses of 10, 20, 30 dan 40 kGy with the dose rate of 7,5 kGy/ hr. Parameters observed were density, compressive strength, and hardness. Experimental results showed that polyvinyl alcohol in the mixture was significant effect to density and compressive strength, where as the irradiation dose was highly significant effect to compressive strength. The effect interaction between dose and polyvinyl alcohol concentration factors had significant effect to density or compressive strength. Almost all samples have pencil hardness of 4 - 5 H, for composite containing 6 % PVA, has pencil hardness of 2 - 3 H

  11. Polarized neutron capture in polarized 59Co and 165Ho nuclei

    International Nuclear Information System (INIS)

    Bosman, J.J.

    1976-01-01

    Gamma spectroscopy on the reactions 59 Co(n,γ) 60 Co and 165 Ho(n,γ) 166 Ho with polarized neutrons and polarized targets enabled the assignment of spins to 36 levels in 60 Co and 15 levels in 166 Ho. Several of them had not been reported earlier. The techniques used to polarize neutron beams and targets and the gamma-spectroscopy are extensively discussed

  12. The effect of gamma radiation from sources "6"0Co of soybean for shade tolerant

    International Nuclear Information System (INIS)

    Lilik Harsanti; Yulidar

    2016-01-01

    Gamma rays are electromagnetic waves that have a very strong penetrating power. One of the sources of gamma rays is from "6"0Co. The gamma rays have strong penetration power can be used of plant breeding to create new genetic diversity in the make of high-yielding varieties. Irradiation of gamma rays at a dose of 300 gray and 400 gray on soybean Denna 1 seed varieties has been done, then it was planted as M.1 the plants look healthy and robust and strong stems. The parameters observed plant height, sum book leaf, sum seed, sum pod and Percentage plant to live shade tolerant. The parameters observed were good: plant height doze 300 Gy (37.76 cm) and 400 gray (33.03 cm) The number of branches with doze 300 Gy (1.75) and 400 Gy (1.95), number of pod with doze 300 Gy (26.25) and 400 Gy (24.72), number of seed with doze 300 Gy (35.55 kg) and 400 Gy (33.65 kg), number of Naut with doze 300 Gy (9.28) and 400 Gy (8.53) and the percentage of plants capable of shade tolerant with doze 300 Gy (85) and 400 Gy(75). In conclusion, selection mutant lines of soybeans shade tolerant at generation M1 and next generation. (author)

  13. Adhesion of thymus lymphocytes to aortic endothelial cells in rats irradiated with sup 60 Co-. gamma. -rays

    Energy Technology Data Exchange (ETDEWEB)

    Yongjian, Geng; Zijun, Mao; Zhiwei, Yin [Suzhou Medical Coll., JS (China)

    1990-03-01

    Adhesion of thymus lymphocytes to aortic endothelial cells in Wistar rats irradiated with {sup 60}Co-{gamma}-rays was preliminarily investigated with a stereological method. The results of experiments suggest that the number of lymphocytes of thymus which adhered to aortic endothelial cells significantly (p < 0.01) decreased after irradiation at doses of 2 and 8 Gy. However, when both thymus and aorta were irradiated, there were more lymphocytes adhering to endothelial cells than that when only thymus was irradiated.

  14. Effect of Zi Gui decoction on immune function in {sup 60}Co {gamma}-ray irradiated mice

    Energy Technology Data Exchange (ETDEWEB)

    Qiujun, Lu; Shafei, Huang; Xipeng, Zhou; Jiayun, Song; Zhongxiong, Tang [Dept. of Pharmacology, Institute of Radiation Medicine, Beijing (China)

    1995-02-01

    Zi Gui decoction (ZG), a complex preparation of traditional Chinese herbal medicine, mainly consists of Radix Angelicae and Radix Astragali. The effects of ZG on mitogen induced proliferation IL-1 and -2 production, natural killer (NK) cell activity in {sup 60}Co {gamma}-ray irradiated mice is investigated. After 5 Gy whole body irradiation. mice were treated i.g. with ZG (1.2, 1.8 g/kg/day) for 20 days. An enhancement in Con A- and LPS-induced proliferations of splenocytes from the two dosage groups were observed. There were marked increases in IL-1 activity in peritoneal macrophage culturesa and IL-2 activity in splenocyte cultures from irradiated mice treated with ZG. The two dosage groups also showed significant potentiation of NK cell activity against YAC-1 target cells. The above results indicated that ZG could promote the recovery of immune functions in {gamma}-ray irradiated mice.

  15. Determination of {sup 60}Co sorption in natural clinoptilolite; Determinacion de la sorcion de {sup 60}Co en clinoptilolita natural

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez B, E.; Granados C, F. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    It was studied the clinoptilolite behavior coming from a deposit in Taxco, Guerrero in hydration and stabilization conditions with sodium for determining its sorption properties. The ion exchange process was carried out through gamma spectrometry using a CoCl{sub 2} solution marked with {sup 60} Co at p H 6.5 in different contact times. It was observed a maximum sorption of 0.408 m eq Co{sup +2}/g mineral, from 0.314 m eq Co{sup +2}/g mineral correspond at ion exchange. (Author)

  16. Determination of 60Co sorption in natural clinoptilolite

    International Nuclear Information System (INIS)

    Hernandez B, E.; Granados C, F.

    1997-01-01

    It was studied the clinoptilolite behavior coming from a deposit in Taxco, Guerrero in hydration and stabilization conditions with sodium for determining its sorption properties. The ion exchange process was carried out through gamma spectrometry using a CoCl 2 solution marked with 60 Co at p H 6.5 in different contact times. It was observed a maximum sorption of 0.408 m eq Co +2 /g mineral, from 0.314 m eq Co +2 /g mineral correspond at ion exchange. (Author)

  17. Evaluation of fruit productivity and quality in Hass avocado submitted to {sup 60}Co gamma radiation; Evaluacion de productividad y calidad de fruta en aguacate Hass sometido a radiacion gamma de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Cruz T, E. De la; Ibanez P, J; Mijares O, P; Garcia A, J M [Instituto nacional de Investigaciones Nucleares, Departamento de Biologia, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    Evaluation of productivity, postharvest behavior and fruit quality was performed on four years Hass avocado trees irradiated with {sup 60} Co gamma rays in doses of 5, 10, 15, 20 and 25 Gy, established in the ''La Labor'' Experimental Center of the Centro de Investigaciones Cientificas y Tecnologias del Aguacate en el Estado de Mexico (CICTAMEX) at Temascaltepec Mexico. Productivity had a significant increase in the dose of 15 Gy being the average number of fruits nearly 400 % more than the control at fruit setting, being such difference reduced at fruit harvesting to 300 %. In regard to postharvest performance, the respiration index (mg CO{sub 2}/kg/hr) did not show significant differences among treatments. Also others variables such as physiological weight losses, texture, maturity pattern, and sensorial tests (color, flavor, aroma, texture) were not different in regard to the control. This mean that radiation has altered productivity but not the quality and postharvest behavior of fruits. (Author)

  18. Evaluation of fruit productivity and quality in Hass avocado submitted to {sup 60}Co gamma radiation; Evaluacion de productividad y calidad de fruta en aguacate Hass sometido a radiacion gamma de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Cruz T, E. De la; Ibanez P, J.; Mijares O, P.; Garcia A, J.M. [Instituto nacional de Investigaciones Nucleares, Departamento de Biologia, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    Evaluation of productivity, postharvest behavior and fruit quality was performed on four years Hass avocado trees irradiated with {sup 60} Co gamma rays in doses of 5, 10, 15, 20 and 25 Gy, established in the ''La Labor'' Experimental Center of the Centro de Investigaciones Cientificas y Tecnologias del Aguacate en el Estado de Mexico (CICTAMEX) at Temascaltepec Mexico. Productivity had a significant increase in the dose of 15 Gy being the average number of fruits nearly 400 % more than the control at fruit setting, being such difference reduced at fruit harvesting to 300 %. In regard to postharvest performance, the respiration index (mg CO{sub 2}/kg/hr) did not show significant differences among treatments. Also others variables such as physiological weight losses, texture, maturity pattern, and sensorial tests (color, flavor, aroma, texture) were not different in regard to the control. This mean that radiation has altered productivity but not the quality and postharvest behavior of fruits. (Author)

  19. Effect of 60Co gamma irradiation on cochlea function and structure in guinea pigs

    International Nuclear Information System (INIS)

    Wang Zhonghe; Cai Yilin; Hu Haisen

    1994-01-01

    In the experiment inner ears of guinea pigs were irradiated with 60 Co gamma rays using the method of simulated clinical routine irradiation in order to find the effects of ionizing radiation on the cochlea function and structure and to explore the mechanism and protective measure that lead to hearing impairment following radiotherapy to the head and neck of cancer patients. Ten weeks after irradiation it was found that ABR threshold increased with increasing dose of radiation. The mean values of ABR thresholds in 70 Gy and 90 Gy groups were 10 dB and 28 dB respectively. The number of inner and outer hair cell and pillar cell loss was counted under microscope. The number of lost cells increased with increasing dose of radiation. The severity of damage in morphology of inner, outer hair cells and pillar cells reduced progressively. The groups of 70 Gy and 90 Gy lost significantly more than groups of control and 50 Gy(P<0.05). It is concluded that the damage of hair cells of cochlea is the direct result of gamma ray irradiation of the inner ear and is the main cause of hearing impairment following irradiation

  20. Effect of Co-60 single escape peak on detection of Cs-137 in analysis of radionuclide from research reactor

    International Nuclear Information System (INIS)

    Kim, M. S.; Park, S. J.

    2006-01-01

    The effect of the single escape peak of 1173 keV gamma-rays from Co-60 on the detection of Cs-137 activity is analyzed. The single escape peak of 1173 keV gamma-rays from Co-60 is located at the 662 keV, which is very close to the energy of gamma-rays from Cs-137. This single escape peak may be mistaken for the gamma-ray peak from Cs-137 activity in the case of large area of 1173 keV peak. The detection of Cs-137 is very important to the judgment of the contamination or the leakage of the material containing the fission product like reactor pool water and in the several experiments for reactor physics such as burn-up estimation. In this work, the areas of the single escape peak of the 1173 keV gamma-rays from Co-60 are measured with several full energy peak areas by using the HPGe detector. The critical limit by which we can decide whether the net count of 662 keV peak due to Co-60 would be significant or not is deduced. For this detection system, when the area of full energy peak is larger than 4.5 million, the single escape peak of 1173 keV gamma-rays from Co-60 can be regarded as the single significant peak. Therefore, it is confirmed that the detection of the Cs-137 activity is affected by the Co-60 in this case. Conservatively, for this detection system, it is recommended that the area of 1173 keV peak of Co-60 would be less than 2 million for neglecting the effect of Co-60. (authors)

  1. Report on salvage of a jammed cobalt-60 source of the gamma beam irradiator at Bangladesh Institute of Nuclear Agriculture (BINA), Mymensingh, Bangladesh

    International Nuclear Information System (INIS)

    Karim, S.M.F.; Awal, K.O.; Ali, M.A.T.

    1997-01-01

    This report is the follow-up of a recovery plan for a Co-60 source that was presented at the proceedings of a symposium at the International Atomic Energy Agency, Vienna during 6-10 November 1989. This report deals mainly with technical measures adopted to salvage the jammed Co-60 source of a gamma irradiator at the Bangladesh Institute of Nuclear Agriculture BINA, Mymensingh, Bangladesh. Different tools and devices were developed to allow the remote recovery of the source. The radiation safety measures taken and the device drawings are given, together with suggestions for future use of the source with the remaining activity for irradiation purposes. (author)

  2. Influence Of Dilution Factor For Activity Measurement Of 60CO

    International Nuclear Information System (INIS)

    Hermawan-Candra; Nazaroh; Ermi-Juita

    2003-01-01

    Influence of dilution factor for activity measurement of 60 Co has been studied. The aim of this research is to determine influence between activity measurement result of 60 Co before and after diluted. Measurement were done by using ionization chamber detectors system and gamma spectrometry system with NaI(TI) detector. Discrepancy within three ionization chambers measurements were 0.2% - 2.1% and NaI(Tl) were 3.5% - 6%. (author)

  3. Effects of 60Co gamma-rays on some biological characteristics of Chinese hamster lung cells

    International Nuclear Information System (INIS)

    Tang Pei; Wang Shoufang; Zhang Shuxian

    1988-01-01

    The proliferation of cells and the relationship between survival and dose were investigated in Chinese hamster lung (CHL) cells grown at stationary phase and irradiated with 60 Co gamma-rays. The ultrastructural changes and chromosome aberration in the cells after irradiation were also observed. The frequency of chromosome aberrations increased linearly with dose and the yields of dicentrics plus rings were best fitted to a linear-quadratic model. The 50% growth-inhibited dose was found to be 4.0Gy. Electron microscopy observation revealed swelling and vacuolation of mitochodria and indistinct cristae at lower doses. The alterations in nucleus at higher doses appeared to be depression of nuclear membrane and disappearance of chromatin

  4. Efect of Gamma 60Co Irradiation on The Growth, Lipid Content and Fatty Acid Composition of Botryococcus sp. Microalgae

    Directory of Open Access Journals (Sweden)

    Dini Ermavitalini

    2017-04-01

    Full Text Available Botryococcus sp. is one of microalgae species that has a high lipid content as much as 75% of their dry weight. But, lipid production by microalgae is regulated by their environmental condition (pH, light, temperature, nutrition, etc. Mutagenesis induced by Gamma 60Co irradiation can be utilized to alter the Botryococcus sp. genetic to get microalgae mutant strain that can produce a higher lipid content than the wild strain. Botryococcus sp. was irradiated with different doses of gamma ray of 60Co  (0, 2, 4, 6, and 10 Gy,  and the effect  on the growth, lipid content, and fatty acid composition of microalgae were observed. Research design used is random complete (RAL with 95 %  confident level for quantitive analysis based on the biomass and lipid contents. More over fatty acid composition was analyzed by Gas Cromatography-Mass Spectrometry (GC-MS. Results showed that Gamma irradiated gave an effect on growth and lipid content of Botryococcus sp. But between the control treatment (0 Gy with microalgae irradiated dose of 2 Gy, 4 Gy and 6 Gy were not significantly different. Whereas between the control with 10 Gy irradiated was significantly different. The highest biomassa and lipid content are found in 10 Gy irradiated microalgae with 0.833 gram biomass and 41% lipid content. Fatty acid profile of Botryococcus sp. control has 6 fatty acids while 10 Gy irradiated microalgae has 12 fatty acids, with the long-chain fatty acids increased, whereas short-chain fatty acids decreased.

  5. Evaluation of fruit productivity and quality in Hass avocado submitted to 60Co gamma radiation

    International Nuclear Information System (INIS)

    Cruz T, E. De la; Ibanez P, J.; Mijares O, P.; Garcia A, J.M.

    1999-01-01

    Evaluation of productivity, postharvest behavior and fruit quality was performed on four years Hass avocado trees irradiated with 60 Co gamma rays in doses of 5, 10, 15, 20 and 25 Gy, established in the ''La Labor'' Experimental Center of the Centro de Investigaciones Cientificas y Tecnologias del Aguacate en el Estado de Mexico (CICTAMEX) at Temascaltepec Mexico. Productivity had a significant increase in the dose of 15 Gy being the average number of fruits nearly 400 % more than the control at fruit setting, being such difference reduced at fruit harvesting to 300 %. In regard to postharvest performance, the respiration index (mg CO 2 /kg/hr) did not show significant differences among treatments. Also others variables such as physiological weight losses, texture, maturity pattern, and sensorial tests (color, flavor, aroma, texture) were not different in regard to the control. This mean that radiation has altered productivity but not the quality and postharvest behavior of fruits. (Author)

  6. Evaluation of myotoxic activity of Bothropstoxin-1 irradiated with 60Co gamma rays

    International Nuclear Information System (INIS)

    Mirco, Jessica; Baptista, Janaina A.; Caproni, Priscila; Yoshito, Daniele; Nascimento, Nanci do

    2009-01-01

    Ionizing radiation has been successfully employed to modify the immunological properties of biomolecules and has been proven to be a powerful tool to attenuate snake venoms toxicity without affecting their immunogenic properties. Snake venoms and their isolated toxins showed structural modifications after gamma radiation process, in aqueous solution, mainly by water radiolysis sub products. Free radical scavengers, such as NaNO 3 and t-butanol, present selective effects on specific radical from water radiolysis. The NaNO 3 has affinity by aqueous electron, while the t-butanol has affinity by hydroxyl radical. At the present work, we have investigated the myotoxic activity of Bothropstoxin-1 (BTHX-1), a K49 phospholipase, present in Bothrops jararacussu crude venom, before and after irradiation process, with or without scavenger substances presence. BTHX-1 was irradiated with 2 kGy of 60 Co gamma rays, in aqueous solution and in the presence of oxygen. BALB/c mice were inoculated with either native or irradiated toxin, with or without scavenger substances. After 3 hours, blood samples were collected and the myotoxic activity was evaluated by LDH (lactate dehydrogenase) release. The muscular tissue damage was directly related to the LDH amounts released. Irradiated Bothropstoxin-1, with or without NaNO 3 substance, caused less damage than their native counterpart. But irradiated toxin, in the presence of t-butanol, was so myotoxic as the native BTHX-1. These results indicate that irradiation of toxic proteins can promote significant modifications on their structures, but still retaining many of the original biological properties of their native counterparts. Additionally, some scavengers substances can change these gamma radiation effects. (author)

  7. A comparison of the survival (LD/sub 50/30/) of a number of inbred mouse strains after X and 60Co gamma irradiation

    International Nuclear Information System (INIS)

    Vacha, J.; Znojil, V.; Hola, J.; Sikulova, J.

    1984-01-01

    The value of LD/sub 50/30/ for X and 60 Co gamma radiation was ascertained for several inbred mouse strains and the significance of interstrain differences in these parameters determined. The rank order of strains according to LD/sub 50/30/ differs as between the two types of radiation with the exception of the strains BALB/c and B10.LP/Ph, which are the least resistant to radiation-induced lethality with both types of radiation. The strain C57BL/10ScSnPh is highly resistant to X irradiation. The relative biological effectiveness of 60 Co gamma radiation as compared with X-radiation from the point of view of lethality fluctuates between 0.748 and 0.952 in individual strains, with a mean value of 0.866 +- 0.033. The RBE values do not correlate with the radiosensitivity of the strain, but they do correlate with the relative contribution to erythropoiesis of the spleen. (author)

  8. Comparison of the survival (LD/sub 50/30/) of a number of inbred mouse strains after X and /sup 60/Co gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Vacha, J.; Znojil, V.; Hola, J.; Sikulova, J. (Ceskoslovenska Akademie Ved, Brno. Biofysikalni Ustav)

    1984-01-01

    The value of LD/sub 50/30/ for X and /sup 60/Co gamma radiation was ascertained for several inbred mouse strains and the significance of interstrain differences in these parameters determined. The rank order of strains according to LD/sub 50/30/ differs as between the two types of radiation with the exception of the strains BALB/c and B10.LP/Ph, which are the least resistant to radiation-induced lethality with both types of radiation. The strain C57BL/10ScSnPh is highly resistant to X irradiation. The relative biological effectiveness of /sup 60/Co gamma radiation as compared with X-radiation from the point of view of lethality fluctuates between 0.748 and 0.952 in individual strains, with a mean value of 0.866 +- 0.033. The RBE values do not correlate with the radiosensitivity of the strain, but they do correlate with the relative contribution to erythropoiesis of the spleen.

  9. Effect of Co-60 gamma radiation on optical, dielectric and mechanical properties of strontium L-ascorbate hexahydrate NLO crystal

    Science.gov (United States)

    Dileep, M. S.; Suresh Kumar, H. M.

    2018-04-01

    A potentially useful nonlinear optical semi-organic single crystal of strontium L-ascorbate hexahydrate (SLAH) was grown by solution growth slow evaporation technique at room temperature. The grown crystal is semi transparent, yellowish in color with monoclinic crystal system having space group P21 and is stable up to 198 °C. Further, SLAH crystals were irradiated with gamma rays produced by 60Co with different doses of 10 KGy, 30 KGy and 50 KGy at room temperature and then studied the effect of gamma-rays on dielectric properties, optical absorption, microhardness and SHG efficiency. The absorption study reveals that the absorbance of the grown crystal is appeared to be low throughout the visible region with a lower cutoff wavelength of 277 nm and these parameters are not affected upon gamma irradiation. The luminescence intensity of the crystal is also not affected by the irradiation. There is noticeable changes were observed in dielectric properties and hardness of the materials for different doses of gamma irradiation. The second harmonic generation (SHG) efficiency of the grown crystal is 0.54 times that of the KDP crystal and is decreased moderately by increasing the dosage of gamma irradiation.

  10. Attenuation of 60Co gamma rays by barium acrylic resin composite shields

    International Nuclear Information System (INIS)

    Abdulla, Riaz; Fidha, Mariyam; Sripathi Rao, B.H.; Kudkuli, Jagadish; Rekha, P.D.; Sharma, S.D.

    2015-01-01

    Oral squamous cell carcinoma is the sixth most common cancer reported globally, with an annual incidence of over 300,000 cases, of which 62% arise in developing countries. Radiation therapy is a treatment modality that uses ionizing radiation as a therapeutic agent. It is widely employed in the treatment of head and neck cancer, as a primary therapy coupled with surgical procedure and chemotherapy or as a palliative treatment for advanced tumors. However, radiotherapy can cause a series of complications such as xerostomia, mucositis, osteoradionecrosis, and radiation caries. Composite circular disc containing different ratios of acrylic and barium sulfate (BaSO 4 ) were made in-house. The purpose of this study was to evaluate the percentage attenuation from these composite shields in 60 Co gamma rays. A maximum of 8% radiation attenuation was achieved using 1:4 ratio of acrylic-BaSO 4 composite shields. The study proposes BaSO 4 as one of the compounds in combination with acrylic resin or any other thermoplastic substances for making biocompatible radiation attenuating devices. (author)

  11. Resposta de sementes de amendoim a diferentes doses de radiação gama (60Co Response of peanut seeds to different levels of gamma radiation (60Co

    Directory of Open Access Journals (Sweden)

    Tatiana da S. Santos

    2010-10-01

    Full Text Available A radiação gama, proveniente da fonte de 60Co, é bastante utilizada para esterilização, visando a prevenção da decomposição e a toxidez de origem microbiana em diversos produtos. O grau de radiossensibilidade de um embrião vegetal depende da espécie, do estágio de seu desenvolvimento durante a radiação, da dose empregada e do critério usado para medir o efeito biológico, sendo comumente utilizado o teste de germinação. Objetivou-se, com este trabalho, estudar a sensibilidade do amendoim a radiação gama e seus efeitos na germinação, no vigor e na micoflora das sementes da cultivar BRS Havana, irradiadas com uma fonte de 60Co, tipo gammacell, com taxa de dosagem de 12,5 kGy h-1. As doses testadas em kGy foram as seguintes: 0; 0,5; 1,0; 1,5; 2,0; 2,5; 3,0; 6,0; 9,0; 12,0; 15,0; 18,0; 21,0 e 24,0. Com os resultados obtidos, concluiu-se que as doses acima de 3,0 kGy prejudicaram a viabilidade das sementes e as doses acima de 12 kGy comprometeram totalmente o vigor e a germinação das sementes de amendoim. A radiação a partir da dose 2,0 kGy eliminou os fungos Aspergillus flavus e Aspergillus niger e, a partir da dose 3,0 kGy, eliminou o Aspergillus glaucus. O Penicilium spp. permaneceu em mais de 30% das sementes em todos os tratamentos com radiação, não sendo eliminado até a dose de 24 kGy.The gamma radiation from 60Co source is widely used for sterilization aiming at preventing decomposition and toxicity from microbes in several products. The degree of radiosensitvity of a plant embryo depends on the species, the development stage during radiation, doses used and the criteria used to measure the biological effect, the germination test, being commonly used.This work aimed to study the peanut sensitivity to gamma radiation and its effects in the germination, in the vigour and seeds microflora of cultivar BRS Havana, irradiated with 60Co source, type gammacell with rate of dosage of 12.5 kGy h-1. The tested doses were the

  12. Biochemical and pharmacological characterization of irradiated crotamine by gamma rays of 60Co

    International Nuclear Information System (INIS)

    Oliveira, Karina Corleto

    2014-01-01

    The serum production in Brazil, the only effective treatment in cases of snakebites, uses horses that although large size, have reduced l lifespan compared with horses not immunized. Ionizing radiation has been shown as an excellent tool in reducing the toxicity of venoms and toxins isolated, and promote the achievement of better immunogens for serum production, and contributing to the welfare of serum-producing animals. It is known, however, that the effects of ionizing radiation on protein are characterized by various chemical modifications, such as fragmentation, cross-linking due to aggregation and oxidation products generated by water radiolysis. However, the action of gamma radiation on toxins is not yet fully understood structurally and pharmacologically, a fact that prevents the application of this methodology in the serum production process. So we proposed in this paper the characterization of crotamine, an important protein from the venom of Crotalus durissus terrificus species, irradiated with 60 Co gamma rays. After isolating the toxin by chromatographic techniques and testing to prove the obtaining of pure crotamine, it was irradiated with gamma rays and subjected to structural analysis, Fluorescence and Circular Dichroism. Using high hydrostatic pressure tests were also conducted in order to verify that the conformational changes caused by radiation suffer modifications under high pressures. From the pharmacological point of view, muscle contraction tests were conducted with the objective of limiting the action of crotamine in smooth muscle as well as the change in the action of toxin caused structural changes to the front. Analysis of Circular Dichroism and Fluorescence showed changes in structural conformation of crotamine when subjected to gamma radiation and that such changes possibly occurring in the secondary and tertiary structure of the protein. The observed in pharmacological tests showed that the irradiated crotamine was less effective in

  13. INCASoy-36: soybean variety obtained in Cuba after the induction of mutations with 60Co gamma rays

    International Nuclear Information System (INIS)

    Ortiz, R; FeII, C de la; Ponce M

    2008-01-01

    INCASoy-36 variety was obtained after irradiating seeds from INCASoy-15 at doses of 240 Gy 60 Co gamma rays. This variety is adapted to summer and winter seedings; however, it can also be used in spring. Besides, its yields can reach up to 3,5-4,0 t.ha-1 grains in summer and spring seedings. It is tolerant to the main pests and diseases; it is especially resistant to Meloidogyne incognita attacks. During the adverse spring season, seeds have been damage tolerant. It can assure high productions with low inputs; therefore, it is feasible to Cuban agriculture. (Author)

  14. Investigations of immunoglobulins, circulating immune complexes and plasma free hemoglobin in cancer patients on 60Co gamma-ray therapy

    International Nuclear Information System (INIS)

    Horvath, M.; Rode, I.L.; Fekete, B.; Kiss, B.; Ringwald, G.

    1981-01-01

    32 patients with different tumours were irradiated by 60 Co gamma-rays. During therapy lasting for several weeks, changes in the content of immunoglobulin and of some other serum proteins, circulating immune complexes and plasma free hemoglobin were determined. Immunosuppression according to immunoglobulin content in serum was not produced by this type of radiation. Decrease in immune complex levels was a good prognostic sign. Low values of plasma hemoglobin content during treatment indicated that no erythrocyte membrane damage had been effected. (orig.) [de

  15. Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine

    International Nuclear Information System (INIS)

    Dulcescu, Mihaela; Murgulet Cristian

    2008-01-01

    The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the calculation of the dose deposited in the patient. (authors)

  16. Eradication of sweet potato weevil using Co-60 gamma radiation

    International Nuclear Information System (INIS)

    Tokunaga, Taizo

    2007-01-01

    Sweet potato weevil which is a harmful insect injuring sweet potatoes was found out at Yoron Island in 1915 for the first time in Kagoshima prefecture, Japan. Here the eradication of sweet potato weevils using cobalt 60 irradiation achieved at Kikai Island is described. The mass-reared male weevils in potatoes are in pasture after sterilized by gamma irradiation. If the sexually sterile male copulates with a wild female, the egg does not incubate. By the repeated sterilization during several generations, the eradication of sweet potato weevils was accomplished. (M.H.)

  17. Poster - 11: Radiation barrier thickness calculations for the GammaPod

    International Nuclear Information System (INIS)

    La Russa, Daniel; Vandervoort, Eric; Wilkins, David

    2016-01-01

    A consortium of radiotherapy centers in North America is in the process of evaluating a novel new 60 Co teletherapy device, called the GammaPod™ (Xcision Medical Systems, Columbia Maryland), designed specifically for breast SBRT. The GammaPod consists of 36 collimated 60 Co sources with a total activity of 4320 Ci. The sources are housed in a hemispherical source carrier that rotates during treatment to produce a cylindrically symmetric cone of primary beam spanning 16° – 54° degrees from the horizontal. This unique beam geometry presents challenges when designing or evaluating room shielding for the purposes of meeting regulatory requirements, and for ensuring the safety of staff and the public in surrounding areas. Conventional methods for calculating radiation barrier thicknesses have been adapted so that barrier transmission factors for the GammaPod can be determined from a few relevant distances and characteristics of the primary beam. Simple formalisms have been determined for estimating shielding requirements for primary radiation (with a rotating and non-rotating source carrier), patient-scattered radiation, and leakage radiation. When making worst case assumptions, it was found that conventional barrier thicknesses associated with linac treatment suites are sufficient for shielding all sources of radiation from the GammaPod.

  18. Poster - 11: Radiation barrier thickness calculations for the GammaPod

    Energy Technology Data Exchange (ETDEWEB)

    La Russa, Daniel; Vandervoort, Eric; Wilkins, David [Radiation Medicine Program, The Ottawa Hospital (Canada)

    2016-08-15

    A consortium of radiotherapy centers in North America is in the process of evaluating a novel new {sup 60}Co teletherapy device, called the GammaPod™ (Xcision Medical Systems, Columbia Maryland), designed specifically for breast SBRT. The GammaPod consists of 36 collimated {sup 60}Co sources with a total activity of 4320 Ci. The sources are housed in a hemispherical source carrier that rotates during treatment to produce a cylindrically symmetric cone of primary beam spanning 16° – 54° degrees from the horizontal. This unique beam geometry presents challenges when designing or evaluating room shielding for the purposes of meeting regulatory requirements, and for ensuring the safety of staff and the public in surrounding areas. Conventional methods for calculating radiation barrier thicknesses have been adapted so that barrier transmission factors for the GammaPod can be determined from a few relevant distances and characteristics of the primary beam. Simple formalisms have been determined for estimating shielding requirements for primary radiation (with a rotating and non-rotating source carrier), patient-scattered radiation, and leakage radiation. When making worst case assumptions, it was found that conventional barrier thicknesses associated with linac treatment suites are sufficient for shielding all sources of radiation from the GammaPod.

  19. Effects of 2. 0 Gy of /sup 60/Co gamma rays irradiation on rat embryos

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Juing-Yi; Satow, Yukio

    1987-01-01

    Pregnant rats of Donryu strain were exposed to a whole-body /sup 60/Co ..gamma.. ray irradiation of a single dose of 2.0 Gy (Dose rate: 0.5 Gy/min) on day 7, 8, 9, 10 or 11 of gestation (sperm day = day 0). The rats were sacrificed on day 18 and the offspring were examined for external and visceral malformations. Malformed embryos occurred between days 7 and 11 with the highest incidence occurring on day 9. Dose with 2.0 Gy increased the rate of resorption or death (52.1 %), in the survivors, caused congenital malformation in a majority of embryos (86.5 %) on day 8 of gestation. There is an increase in malformation (93.3 %) and growth retardation, but no increase in mortality (42.9 %) on day 9 of gestation. Relatively few anomalies resulted from irradiation on day 7 of gestation. The peak day for cardiovascular anomalies occurred on day 9 (88.3 % of all survival embryos) with high levels also occurring on day 8 (86.5 %). Cardiovascular anomalies consisted of VSD, hypoplasia of the pulmonary trunk, coarctation of the aorta, double aortic arch, right aortic arch, riding aorta, complete transposition of the aorta, persistent atrioventricular canal, vascular ring, aberrant right subclavian artery and others. Similar anomalies, but at a lower incidence, were produced by /sup 60/Co ..gamma.. ray at dose levels of 2.0 Gy on day 10 or 11 of gestation. Cases of cleft lip and cleft palate or facial cleft were observed seventeen fetuses on day 9 of gestation (31 %). Exencephaly occurred in nine embryos treated on day 9 (16.1 %) and in one embryos treated on day 10. Tail defects appeared with treatment on day 9 with the latter predominating on day 11. The present study show that maximum resorption (52.1 %) was seen with treatment on day 8 whereas the highest rate of malformation (93.3 %) was observed with treatment on day 9. (J.P.N.).

  20. Evaluation through comet assay of DNA damage induced in human lymphocytes by alpha particles. Comparison with protons and Co-60 gamma rays

    International Nuclear Information System (INIS)

    Di Giorgio, M.; Kreiner, A. J.; Schuff, J. A.; Vallerga, M. B.; Taja, M. R.; Lopez, F. O.; Alvarez, D. E.; Saint Martin, G.; Burton, A.; Debray, M. E.; Kesque, J. M.; Somacal, H.; Stoliar, P.; Valda, A.; Davidson, J.; Davidson, M.; Ozafran, M. J.; Vazquez, M. E.

    2004-01-01

    Several techniques with different sensitivity to single-strand breaks and/or double strand breaks were applied to detect DNA breaks generated by high LET particles. Tests that assess DNA damage in single cells might be the appropriate tool to estimate damage induced by particles, facilitating the assessment of heterogeneity of damage in a cell population. The microgel electrophoresis (comet) assay is a sensitive method for measuring DNA damage in single cells. The objective of this work was to evaluate the proficiency of comet assay to assess the effect of high LET radiation on peripheral blood lymphocytes, compared to protons and Co-60 gamma rays. Materials and methods: Irradiations of blood samples were performed at TANDAR laboratory (Argentina). Thin samples of human peripheral blood were irradiated with different doses (0-2.5 Gy) of 20.2 MeV helium-4 particles in the track segment mode, at nearly constant LET. Data obtained were compared with the effect induced by a MeV protons and Co-60 gamma rays. Alkaline comet assay was applied. Comets were quantified by the Olive tail moment. Distribution of the helium-4 particle and protons were evaluated considering Poisson distribution in lymphocyte nuclei. The mean dose per nucleus per particle result 0.053 Gy for protons and 0.178 Gy for helium-4 particles. When cells are exposed to a dose of 0.1 Gy, the hit probability model predicts that 43% of the nuclei should have experienced and alpha traversal while with protons, 85% of the nuclei should be hit. The experimental results show a biphasic response for helium-4 particles (0.1 Gy), indicating the existence of two subpopulations: unhit and hit. Distributions of tail moment as a function of fluence and experimental dose for comets induced by helium-4 particles, protons and Co-60 gamma rays were analyzed. With helium-4 irradiations, lymphocyte nuclei show an Olive tail moment distribution flattened to higher tail moments a dose increase. However, for irradiations with

  1. Studies on cannabis. III. Young plants from the seed irradiated with /sup 60/Co gamma rays for inhibiting their development after seeding

    Energy Technology Data Exchange (ETDEWEB)

    Shimomura, H; Kuriyama, E; Tomizawa, A [Tokyo Coll. of Pharmacy (Japan)

    1976-01-01

    The seedlings from Cannabis sativa L. seeds irradiated with different doses of ..gamma..-rays were examined, in order to determine the dose sufficient to kill the young plants naturally, before their hallucinnogenic component increases. The seeds of ''Minamioshihara No. 1'', which were harvested in 1972 in Tochigi Prefecture, were irradiated with eight different doses of /sup 60/Co ..gamma..-rays in January 17, 1973, and the seedlings were examined several times during the subsequent 9 months, from March to November 1973, and their morphological and histological effects were examined, and the results are summarized as follows: Samples irradiated with 1500 and 1000 krads developed radicles about 3 mm in length. Samples irradiated with 500, 200, and 50 krads grew into young plants with the first set of leaves, without lateral roots. Samples irradiated with 30 krads grew to about 10 cm high with a few lateral roots, and the epicotyls about 1 cm in length. These young plants from the irradiated seeds stayed in the same condition and then died. Samples irradiated with 15 and 5 krads grew in the same way as the controls until the stage of flowering. Samples irradiated with 500, 200, 50, and 30 krads showerd the cell membranes of endodermis and pericycle to be partially lignified and suberized. The degree of change was related to the dose of ..gamma..-rays. Samples irradiated with 30 krads showed withered cells near the end of the lateral nerves on the first and second set of leaves. The economical dose of /sup 60/Co ..gamma..-rays for inhibiting young plants from developing into adult ones was a minimum of 30 krads which made the young plants die. Irradiation with 50 krads of ..gamma..-rays will be required to kill the young plants completely before they develop the hallucinogenic component.

  2. Effects of Co60 gamma radiation on Biomphalaria glabrata (Say, 1818) Embryo. II. Malformations

    International Nuclear Information System (INIS)

    Okazaki, K.; Kawano, T.

    1990-01-01

    The morphogenetic effects of ionizing radiation were investigated in Biomphalaria glabrata embryos irradiated in the cleavage, blastula, gastrula, young trochophore and trochophore stages with 5 to 25 Gy doses of 60 CO gamma radiation. The number of malformed embryos rapidly increased with increasing radiation dose, reaching a maximum between 5th to 8th day after irradiation in all stages analyzed. Susceptibility to malformation induction was higher the younger than the age of the irradiated embryo. However, for the cleavage stage the frequency of malformed embryos was inversely proportional to radiation dose for the same radiation dose. Several types of morphogenetic malformations were obtained, among then cephalic malformations, exogastrula, shell malformations and embryos with everted stomodeum, unspecific malformations being the most frequent. The results show that the types of malformation induced by radiation probably are not radiation-specific and do not depend on the dose applied [pt

  3. Effect of. gamma. -radiation of /sup 60/Co on bacteria Sphaerotilus natans in nutrient medium containing calcium and lithium

    Energy Technology Data Exchange (ETDEWEB)

    Leonowicz-Babiak, K; Radziwolska, E; Widera, M

    1980-01-01

    The effect of ..gamma..-radiation of /sup 60/Co on an increase in dry matter of the polysaprobic zone bacteria Sphaerotilus natans was studied. Bacterial growth depended on the radiation dose absorbed. With a rise of the dose, the bacterial dry matter usually decreased. This relationship was not observed at a radiation dose of 72 krad. In the presence of calcium in the medium, the bacterial dry matter increased. An addition of lithium salt to the medium failed to increase the bacterial dry matter.

  4. Evaluation of myotoxic activity of Bothropstoxin-1 irradiated with {sup 60}Co gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Mirco, Jessica; Baptista, Janaina A.; Caproni, Priscila; Yoshito, Daniele; Nascimento, Nanci do [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil)], e-mail: jessica.mirco@yahoo.com.br, e-mail: janabap@gmail.com, e-mail: pricaproni@hotmail.com, e-mail: daniyoshito@uol.com.br, e-mail: nnascime@ipen.br

    2009-07-01

    Ionizing radiation has been successfully employed to modify the immunological properties of biomolecules and has been proven to be a powerful tool to attenuate snake venoms toxicity without affecting their immunogenic properties. Snake venoms and their isolated toxins showed structural modifications after gamma radiation process, in aqueous solution, mainly by water radiolysis sub products. Free radical scavengers, such as NaNO{sub 3} and t-butanol, present selective effects on specific radical from water radiolysis. The NaNO{sub 3} has affinity by aqueous electron, while the t-butanol has affinity by hydroxyl radical. At the present work, we have investigated the myotoxic activity of Bothropstoxin-1 (BTHX-1), a K49 phospholipase, present in Bothrops jararacussu crude venom, before and after irradiation process, with or without scavenger substances presence. BTHX-1 was irradiated with 2 kGy of {sup 60}Co gamma rays, in aqueous solution and in the presence of oxygen. BALB/c mice were inoculated with either native or irradiated toxin, with or without scavenger substances. After 3 hours, blood samples were collected and the myotoxic activity was evaluated by LDH (lactate dehydrogenase) release. The muscular tissue damage was directly related to the LDH amounts released. Irradiated Bothropstoxin-1, with or without NaNO{sub 3} substance, caused less damage than their native counterpart. But irradiated toxin, in the presence of t-butanol, was so myotoxic as the native BTHX-1. These results indicate that irradiation of toxic proteins can promote significant modifications on their structures, but still retaining many of the original biological properties of their native counterparts. Additionally, some scavengers substances can change these gamma radiation effects. (author)

  5. Semi-Broad-Beam Gamma Spectrometry of Some Mixtures and Solutions

    International Nuclear Information System (INIS)

    El-Kateb, A.H.

    2000-01-01

    The 33- and 662-keV X rays and gamma rays from 137 Cs and the 1173- and 1333-keV gamma rays from 60 Co have been employed as single and dual beams to study the attenuation of applied materials. These materials are soil containing water, dextrose solutions, and solutions of lithium chloride, sodium chloride, and potassium chloride. In soil the measurements covered water content ranging from saturation to nearly dry points. For dextrose, the content ranged from 0.25 g.cm -3 to zero. For the chloride solutions, the salt mass fraction was varied up to the ratio 0.1667. The setup geometry was arranged with a source-detector angle of 8.63 deg to allow good reception of the 33-keV line. The results were analyzed on the basis of the dependence of the absorption of intensity (intensities) on the content of the added component. The curves are fitted with concentration-dependent expansions, the coefficients of which are tabulated. It is concluded that soft X rays (33 keV) produce the most sensitive responses to concentrations. Correspondingly, a dual energy of 33 and 1250 keV (or 1333 keV) is the preferred combination to detect a desired component in a sample

  6. 60Co Transfer Factor From Lutosol Soil To Leafy Vegetable (Ipomea reptans poir)

    International Nuclear Information System (INIS)

    Leli-Nirwani; Jumaher; Wahyudi

    2003-01-01

    It has been conducted 60 Co transfer study from Lutosol soil to leafy vegetable plant by using pot treatment system. The aim of the research is to obtain data of the transfer factor of 60 Co from lutosol soil to leafy vegetable plant. Pot experiment was carried out by using the complete random design to evaluate two treatment, namely soil with 60 Co and without 60 Co (as a control). 60 Co concentration was with 6.1371 kBq/pot. Tested plant and control plant amount to 12 pots. Each pot contains 1 kg of soil. After harvesting, the weight of dry plant was determined and was conducted with Spectrometer Gamma to 60 Co concentration in dry plant and dry soil. Transfer factor was found to between 0.02 and 0.68 and the average is 0.2068. (author)

  7. Disinfection of wastewaters: high-energy electron vs gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Farooq, S [King Fahd Univ. of Petroleum and Minerals, Dhahran (Saudi Arabia). Dept. of Civil Engineering; Kurucz, C N; Waite, T D [Miami Univ., Coral Gables, FL (United States); Cooper, W J [Florida International Univ., Miami, FL (United States). Drinking Water Research Center

    1993-07-01

    A study was undertaken to examine the sensitivity of a wastewater population of coliphage, total coliforms and total flora present in raw sewage and secondary effluent after irradiating with similar doses delivered by a high-energy electron beam and [gamma]-radiation. The electron beam study was conducted on a large scale at the Virginia Key Wastewater Treatment Plant, Miami, Florida. The facility is equipped with a 1.5 MeV, 50 mA electron accelerator, with a wastewater flow rate of 8ls[sup -1]. Concurrent [gamma]-radiation studies were conducted at laboratory scale using a 5000 Ci, [sup 60]Co [gamma]-source. Three logs reduction of all three test organisms were observed at an electron beam dose of 500 krads, while at least four logs reduction were observed at the same dose utilizing the [gamma]'source. (Author).

  8. TLD postal dose quality audit service for Co-60 beams in reference conditions in Cuba

    International Nuclear Information System (INIS)

    Gutierrez Lores, S.; Walwyn Salas, G.; Alonso Villanueva, G.

    2008-01-01

    This report presents the methodology and experience of the Cuban's Secondary Standard Dosimetry Laboratory for the implementation of postal dose quality audits service for Co-60 beams in reference conditions, using TLDs. Under coordinated research project (Contract 10794) were bought (TLD -100) Tl rods type JR 1152F made in China, with dimensions of 6 mm x 1 mm x 1 mm. All of these rods were identified individually with a consecutive number made over one of its sides, using a fine tip of graphite. The method used to determinate the individual sensibility of the TL detectors was: irradiating a group of them, with the same history of irradiation and readout (100 rods approximately), four serial times in the same geometrical conditions, to read them out and to attribute to each of them a sensitivity factor. This sensitivity factor is equal to average for the 4 cycle of irradiation and readout of the quote between the TL readout from dosimeter i and the mean of all values for each cycle. The TLD signal was read using HARSHAW 2000C/B reader. The results obtained in the external verification of the accuracy of the dose determination by the TLD system were performed in cooperation with IAEA Dosimetry Laboratory at Seibersdorf in different years are shown, the results obtained of the quality audits carried out to the different services of radiotherapy of the country are analysed also. The quality audits are an useful tool for the improvement of the accuracy in the dosimetry of clinical beams of radiotherapy with Co-60, contributing this way to the improvement of the life quality to cancer patients of the Cuban system of health. (author)

  9. Fission product gamma-ray sources as an alternative to cobalt-60 sources for sewage sludge sterilization

    International Nuclear Information System (INIS)

    Herrnberger, V.R.D.

    1975-01-01

    The sterilization of sewage sludge is now performed successfully using 60 Co gamma-ray sources. The question arises whether more economic gamma-ray sources exist that could replace the 60 Co source. The following types of sources are considered: Spent fuel elements; mixtures of solidified fission products; and isolated solidified fission products such as 134 / 137 Cs. For a particular irradiation plant the specific source costs (S.Fr./Ci) and their contribution to the irradiation costs for 1 m 3 of sewage irradiated to a dose of 250 krad(S.Fr./m 3 ) are determined and compared with the costs of a plant using a 60 Co source. The encapsulation costs and the effect of the gamma absorption of the source are taken into account. Different encapsulation and source management techniques are reviewed to find the most economic for each source type. A spent fuel element irradiation facility is recommended for use either in combination with a sewage water purification plant or as part of a power reactor station where it replaces the storage water pool for the spent fuel elements. Additional source capsules are not envisaged, as long as double-walled source containers are used. The fission product mixtures are enclosed in double-walled capsules of two different forms: Small cylindrical rods and hollow cylinders. For caesium and cobalt cylindrical rods only are used. The main conclusions of the study are that the highest irradiation costs arise from the use of a fission product mixture source. The costs are, however, only 15% above those of a 60 Co plant. To be competitive the flow-rate has to be adapted to the decreasing activity of the source, resulting in a reduction to 20% within ten years of source utilization. The integrated irradiation plant with a spent fuel element source offers irradiation costs comparable with those of a 60 Co plant, if the flow-rate is constant during one year of source utilization. The irradiation costs are reduced to 25% of those of a 60 Co plant

  10. Analysis of interface states and series resistance at MIS structure irradiated under {sup 60}Co {gamma}-rays

    Energy Technology Data Exchange (ETDEWEB)

    Tataroglu, A. [Department of Physics, Faculty of Arts and Sciences, Gazi University, 06500 Ankara (Turkey)], E-mail: ademt@gazi.edu.tr; Altindal, S. [Department of Physics, Faculty of Arts and Sciences, Gazi University, 06500 Ankara (Turkey)

    2007-10-11

    In this research, we investigated the effect of {sup 60}Co {gamma}-ray exposure on the electrical properties of Au/SnO{sub 2}/n-Si (MIS) structures using current-voltage (I-V) measurements. The fabricated devices were exposed to {gamma}-ray doses ranging from 0 to 300 kGy at a dose rate of 2.12 kGy h{sup -1} in water at room temperature. The density of interface states N{sub ss} as a function of E{sub c}-E{sub ss} is deduced from the forward bias I-V data for each dose by taking into account the bias dependence effective barrier height and series resistance of device at room temperature. Experimental results show that the {gamma}-irradiation gives rise to an increase in the zero bias barrier height {phi}{sub BO}, as the ideality factor n and N{sub ss} decrease with increasing radiation dose. In addition, the values of series resistance were determined using Cheung's method. The R{sub s} increases with increasing radiation dose. The results show that the main effect of the radiation is the generation of interface states with energy level within the forbidden band gap at the insulator/semiconductor interface.

  11. Co60 and Cs137 gamma radiation effects on textured bscco Superconducting fibers

    International Nuclear Information System (INIS)

    Leyva Fabelo, A.; Bouza Dominguez, J.; Cruz Inclan, Crlos M.

    2001-01-01

    Bi2Sr2CaCu2Ox superconducting fibers synthesized by solid state reaction and textured by the method of zonal laser ablation were irradiated with gamma rays of 1.25 MeV and 662 keV and studied the behavior of some of its properties with the exposition dose. The measurements of dynamic magnetic susceptibility were used for the characterization of the samples. It was observed that for the dose of up to 600 kGy in the case of the Co60 and until 500 mGy for the Cs137, the fibers preserve its superconducting intragrain properties. It is an evidence of the high resistance of the material to the radiacional damage. In all the cases were verified that with the increase of the dose the Ton of the transition grows. Two possible mechanisms that play the most important role in this effect are explained in the text. The ac measurements allowed to verified the increasing behavior of the superconducting volume fraction in the sample with the exposition dose

  12. Effect of low doses of gamma radiation of Co-60 (radio-hormesis) in tomato seeds; Efeitos de baixas doses de radiacao gama do Co-60 (radio-hormesis) em sementes de tomate

    Energy Technology Data Exchange (ETDEWEB)

    Wiendl, Toni Andreas

    2010-07-01

    Tomato seeds of the Gladiador hybrid were exposed to gamma radiation of Co-60 with the following doses: 0; 2,5; 5; 7,5; 10; 12,5; 15 e 20 Gy. Analysis were performed on germination, seedlings height to cotyledon, seedling total height, seedling fresh and dry weight, plant height, stalk diameter at the root beginning, fresh and dry weight of the 5{sup th} leaf, number of green fruits with diameter higher than 3 cm, number of green, half ripen and ripen fruits, total number of fruits, Brix and pH of fruits, average fruit weight and fruit total production. A variety of stimulation effects were observed on the different plant developing stages. The greatest stimulus for production was observed in the 10 Gy dose. The highest seedling average height and plant average height were observed for the 7,5 Gy dose. The biggest number of green fruits with diameter higher than 3 cm occurred for the 12,5 and 15 Gy treatments. Irradiation also stimulated a higher total number of fruits in all doses, having advantage the 10 Gy dose which produced 88% more fruits than control as well as 86% more weight production. The fruits pH acidified significantly in a dose of 12,5 Gy and higher. Production increased in all treatments comparing to control and the highest stimulus for production observed was for the 10, 12,5 and 15 Gy. The use of low gamma radiation doses of Co-60 applied as pre-sowing treatment in the seeds, efficiently stimulated the development of plants and the tomato production. (author)

  13. DOSKMF2, Dose Rate Distribution in Co60 Gamma Irradiation Plants

    International Nuclear Information System (INIS)

    Remer, M.

    1988-01-01

    1 - Description of program or function: The DOSKMF2 code calculates dose rate distributions in gamma irradiation facilities with 60 Co sources. It has been developed as a tool for the evaluation of research units for the characterization, modification and optimization as well as for the simulation, planning design and evaluation of pilot and industrial facilities. 2 - Method of solution: The basic model of DOSKMF2 contains the computation of the exposure rate, which is dependent on a system of radiation sources (line and/or point sources) at one point of the radiation field. The geometric conditions are described by two coordinate systems. The first is used to arrange the radiation sources and tubes; the second is used to describe the shielding layers in the form of concentric circles. The build-up factor is approximated by Taylor coefficients, also in the case of multi-layer configurations. Calculations of radiation fields in complex irradiation facilities are made by many organizational variants based on the basic model. The interpretation of the results is supported by some statistical calculations. It is possible to store the calculated dose rate values for further processing. 3 - Restrictions on the complexity of the problem: The DOSKMF2 code is presently limited to 40 irradiation tubes and 10 crossed shielding layers. This can be increased by changing dimension statements and input organization

  14. Gamma radiation effects of {sup 60} Co on Bombyx mori (Lep., Bombycidae) modifying the silk fiber production; Influencia da radiacao gama ({sup 60} Co) na producao de fios de seda em Bombyx mori(Lep.,Bombycidae)

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro Junior, Francisco [Universidade Metodista de Piracicaba (UNIMEP), SP (Brazil); Bendassolli, Jose A. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)

    1997-12-01

    The present work aimed to verify the biological effects of the application of different doses of gamma radiation during the fifth instar of the silkworm catepillar. Sevently eight silkworm caterpillars (Bombyx mori) were irradiated with {gamma}{sup 60} Co radiation at the initial period of the fifth instar. The caterpillars were divided and classified in six batches of thirteen individuals each. Treatments 1 through 5 received 20, 40, 60, 80 and 100 Gy, respectively, and the control, also consisted of thirteen caterpillars, was not irradiated. The results showed a general increase in the silk fiber content in the irradiated batches compared to the control. The weight of the silk cocoons was higher with increasing doses of irradiation, from 20 to 80 Gy, respectively, followed by a decrease in weight in the treatment irradiated with 100 Gy. the results obtained in this experiment enable the conclusion that the radiation applied to the caterpillars significantly influenced the production of silk fiber in this species. (author). 4 refs., 2 figs., 3 tabs.

  15. Biochemical and pharmacological studies of native and irradiated crotamine with gamma radiation of {sup 60}Co; Estudo bioquimico e farmacologico das crotaminas nativa e irradiada com radiacao gama de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Mitake, Malvina Boni

    2000-07-01

    Ionizing radiation can change the molecular structure and affect the biological properties of biomolecules. This has been employed to attenuate animal toxins. Crotamine is a strongly basic polypeptide from the South American rattlesnake venom, composed of 42 amino acid residues. It induces skeletal muscle spasms leading to a spastic paralysis of hind limbs in mice. The objective of this thesis was carry out biochemical and pharmacological studies of native and irradiated crotamine with {sup 60} Co. Crotamine was purified from Crotalus durissus terrificus venom by Sephadex G-100 gel filtration followed by ion exchange chromatography, using a Fast Performance Liquid Chromatography (FPLC) system. It was irradiated at 2 mg/ml in 0.15 M Na Cl with 2.0 kGy gamma radiation emitted by a {sup 60} Co source. The native and irradiated crotamine were evaluated by biochemical characterization, toxic activity (LD{sub 50} and biodistribution. The native and irradiated crotamine were labelled with 29.6 MBq of {sup 125} I using chloramine T method, and separated in a Sephadex G-50 column. Male Swiss mice (35{+-} 5 g), were injected i.p. with o.1 mL (2.4 x 10{sup 6} cpm/mouse) of {sup 125} I native crotamine or with 0.4 mL (1.3 x 10{sup 6} cpm/mouse) of {sup 125} I irradiated crotamine. At 0.08; 0.25; 0.5; 1; 2; 4; 8; 12 and 24 hours the animal were killed by ether inhalation. Blood, spleen, liver, kidneys, brain, lungs, heart, and skeletal muscle were collected in order to determine radioactivity content. The results showed that gamma radiation did not change the protein concentration, the electroforetic profile or the primary structure of the protein, although differences were shown by spectroscopic techniques. The gamma radiation diminished the toxicity of crotamine, but it did not abolish bioactivity. Biodistribution studies showed that native and irradiated crotamine have hepatic metabolism and renal elimination. The native and irradiated crotamine have affinity by skeletal

  16. Studies on apple preservation by 60 -gamma irradiation

    International Nuclear Information System (INIS)

    Wang Chuanyao; Jiang Mengyue; Gao Meixu

    1992-01-01

    Studies on '60'Co-gamma irradiation of Golden Delicious apple have been carried out. The results showed that the optimum irradiation dosage for stored apple was ranged from 0.3-0.5 k Gy, with this dosage, the contents of vitamin c and titratalbe acidity in these apples had no significant change compared with unirradiated apples. The respiratory rate and the amount of ethylene release were decreased after irradiation. The mortality of the verticillate pathogenic fungi was 97% at the dose of 0.5 k Gy

  17. Gamma radiation effects of 60 Co on Bombyx mori (Lep., Bombycidae) modifying the silk fiber production

    International Nuclear Information System (INIS)

    Carneiro Junior, Francisco; Bendassolli, Jose A.

    1997-01-01

    The present work aimed to verify the biological effects of the application of different doses of gamma radiation during the fifth instar of the silkworm catepillar. Sevently eight silkworm caterpillars (Bombyx mori) were irradiated with γ 60 Co radiation at the initial period of the fifth instar. The caterpillars were divided and classified in six batches of thirteen individuals each. Treatments 1 through 5 received 20, 40, 60, 80 and 100 Gy, respectively, and the control, also consisted of thirteen caterpillars, was not irradiated. The results showed a general increase in the silk fiber content in the irradiated batches compared to the control. The weight of the silk cocoons was higher with increasing doses of irradiation, from 20 to 80 Gy, respectively, followed by a decrease in weight in the treatment irradiated with 100 Gy. the results obtained in this experiment enable the conclusion that the radiation applied to the caterpillars significantly influenced the production of silk fiber in this species. (author). 4 refs., 2 figs., 3 tabs

  18. Growing, regeneration and radiosensibility of sugarcane callus (Saccharum spp. hybrid var. “SP 70-1284” treated with gamma radiation source 60Co.

    Directory of Open Access Journals (Sweden)

    Apolonio Valdez Balero

    2004-07-01

    Full Text Available Calluses in growth of sugar cane, variety “SP 70-1284”, were radiated with a source of 60Co. The studied doses were between 10 and 80 Gy. The affectation of the Gamma radiation source 60Co in the growth of the callus and the regeneration of plants was evaluated. The results indicated that the dose that diminished the growth of callus in a value under 50% was the one of 30 Gy, and also the dose that diminished the regenerative capacity of the callus below to the 50% of the population was the one of 30 Gy. The results showed that for this variety of sugar cane doses superior to 30Gy of Gamma radiations jeopardizes the growth and the later regeneration of the callus. Its application is recommended to induce genetic variability in the variety of sugar cane “SP 70-1284”, as well as in programs of genetic improvement by mutations, in susceptible varieties of the sugar cane red blight (Puccinia melanocephala Syd using calluses in growth. Key words: callus, hybrid, in vitro, improvement, rust, Saccharum sp, variability

  19. Effects of Co60 gamma radiation on the immunogenic and antigenic properties of Bothrops jararacussu venom

    International Nuclear Information System (INIS)

    Spencer, Patrick J.; Nascimento, Nanci do; Rogero, Jose R.

    1997-01-01

    Ionizing radiation has been successfully employed to attenuate animals toxins and venoms for immunizing antisera producing animals. However, the radiation effects on antigenicity and immunogenecity have not yet been elucidated. In the present work, we investigated the effects of gamma rays on the antigenic and immunogenicity have not yet been elucidated. In the present work, we investigated the effects of gamma rays on the antigenic and immunogenic behaviour of Bothrops jararacussu venon. Venom samples (2mg/ml in 150 mM NaCl) were irradiated with 500, 1000 and 2000 Gy of 60 Co gamma rays. These samples were submitted to antigen capture ELISA on plates coated with commercial bothropic antiserum. Results suggest a loss of reactivity of the 1000 and 2000 Gy irradiated samples. Antibodies against native and 2000 Gy irradiated venoms were produced in rabbits. Both sera able to bind native venom with a slightly higher titer for anti-irradiated serum. These data suggest that radiation promoted structural modification on the antigen molecules. However since the antibodies produced against irradiated antivenom were able to recognize native venom, there must have been preservation of some antigenic determinants. It has already been demosntrated that irradiation of proteins leads to structural modifications and unfolding of the molecules. Our data suggest that irradiation led to conformational epitopes destruction with preservation of linear epitopes and that the response against irradiated venom may be attributed to these linear antigenic determinants. (author). 8 refs., 3 figs

  20. High and low energy gamma beam dump designs for the gamma beam delivery system at ELI-NP

    International Nuclear Information System (INIS)

    Yasin, Zafar; Matei, Catalin; Ur, Calin A.; Mitu, Iani-Octavian; Udup, Emil; Petcu, Cristian

    2016-01-01

    The Extreme Light Infrastructure - Nuclear Physics (ELI-NP) is under construction in Magurele, Bucharest, Romania. The facility will use two 10 PW lasers and a high intensity, narrow bandwidth gamma beam for stand-alone and combined laser-gamma experiments. The accurate estimation of particle doses and their restriction within the limits for both personel and general public is very important in the design phase of any nuclear facility. In the present work, Monte Carlo simulations are performed using FLUKA and MCNPX to design 19.4 and 4 MeV gamma beam dumps along with shielding of experimental areas. Dose rate contour plots from both FLUKA and MCNPX along with numerical values of doses in experimental area E8 of the facility are performed. The calculated doses are within the permissible limits. Furthermore, a reasonable agreement between both codes enhances our confidence in using one or both of them for future calculations in beam dump designs, radiation shielding, radioactive inventory, and other calculations releated to radiation protection. Residual dose rates and residual activity calculations are also performed for high-energy beam dump and their effect is negligible in comparison to contributions from prompt radiation.

  1. High and low energy gamma beam dump designs for the gamma beam delivery system at ELI-NP

    Energy Technology Data Exchange (ETDEWEB)

    Yasin, Zafar, E-mail: zafar.yasin@eli-np.ro; Matei, Catalin; Ur, Calin A.; Mitu, Iani-Octavian; Udup, Emil; Petcu, Cristian [Extreme Light Infrastructure - Nuclear Physics / Horia Hulubei National Institute for R& D in Physics and Nuclear Engineering, Bucharest-Magurele (Romania)

    2016-03-25

    The Extreme Light Infrastructure - Nuclear Physics (ELI-NP) is under construction in Magurele, Bucharest, Romania. The facility will use two 10 PW lasers and a high intensity, narrow bandwidth gamma beam for stand-alone and combined laser-gamma experiments. The accurate estimation of particle doses and their restriction within the limits for both personel and general public is very important in the design phase of any nuclear facility. In the present work, Monte Carlo simulations are performed using FLUKA and MCNPX to design 19.4 and 4 MeV gamma beam dumps along with shielding of experimental areas. Dose rate contour plots from both FLUKA and MCNPX along with numerical values of doses in experimental area E8 of the facility are performed. The calculated doses are within the permissible limits. Furthermore, a reasonable agreement between both codes enhances our confidence in using one or both of them for future calculations in beam dump designs, radiation shielding, radioactive inventory, and other calculations releated to radiation protection. Residual dose rates and residual activity calculations are also performed for high-energy beam dump and their effect is negligible in comparison to contributions from prompt radiation.

  2. Progress towards a semiconductor Compton camera for prompt gamma imaging during proton beam therapy for range and dose verification

    Science.gov (United States)

    Gutierrez, A.; Baker, C.; Boston, H.; Chung, S.; Judson, D. S.; Kacperek, A.; Le Crom, B.; Moss, R.; Royle, G.; Speller, R.; Boston, A. J.

    2018-01-01

    The main objective of this work is to test a new semiconductor Compton camera for prompt gamma imaging. Our device is composed of three active layers: a Si(Li) detector as a scatterer and two high purity Germanium detectors as absorbers of high-energy gamma rays. We performed Monte Carlo simulations using the Geant4 toolkit to characterise the expected gamma field during proton beam therapy and have made experimental measurements of the gamma spectrum with a 60 MeV passive scattering beam irradiating a phantom. In this proceeding, we describe the status of the Compton camera and present the first preliminary measurements with radioactive sources and their corresponding reconstructed images.

  3. Total integrated dose testing of solid-state scientific CD4011, CD4013, and CD4060 devices by irradiation with CO-60 gamma rays

    Science.gov (United States)

    Dantas, A. R. V.; Gauthier, M. K.; Coss, J. R.

    1985-01-01

    The total integrated dose response of three CMOS devices manufactured by Solid State Scientific has been measured using CO-60 gamma rays. Key parameter measurements were made and compared for each device type. The data show that the CD4011, CD4013, and CD4060 produced by this manufacturers should not be used in any environments where radiation levels might exceed 1,000 rad(Si).

  4. An industrial 60Co gamma irradiation facility in China

    International Nuclear Information System (INIS)

    Jin Yongling; Zhou Ruiying; Wang Binglin

    1990-01-01

    The radiation processing has developed very fast in China since 1980. There are more than 100 of 60 Co radiation facilities having been set up. Majority of them was with relatively small capacity and was used mainly for the laboratory study. An industrial radiation facility has been established and put into operation in Beijing Radiation Application Center (BRAC) recently. The project was based on the research works of irradiation technology during the period of 1980-1985. The main pre-research work was radiation sterilization of medical products and food irradiation. This work has obtained an award from State Commission of Science and Technology. The Commission has arranged the construction of an industrial sterilization plant for medical products as a major import project. The project has also been supported by IAEA as project CPR/8/002. The project includes a plant of production of 100,000,000 needles per year, a plant of production of 50,000,000 syringes per year and an automatic irradiation plant. All three parts have been set up now. The maximum capacity of 60 Co sources is 3.7 x 10 16 Bq, the first-time-loaded source is 12.21 x 10 15 Bq. (author)

  5. Radiation inactivation of Paenibacillus larvae and sterilization of American Foul Brood (AFB) infected hives using Co-60 gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    De Guzman, Zenaida M. [Microbiological Research and Service Laboratory, Atomic Research Division, Philippine Nuclear Research Institute, Diliman, Quezon City (Philippines); Cervancia, Cleofas R. [Institute of Biological Sciences, College of Arts and Sciences, University of the Philippines, Los Banos, Laguna (Philippines); Dimasuay, Kris Genelyn B.; Tolentino, Mitos M.; Abrera, Gina B.; Cobar, Ma. Lucia C. [Microbiological Research and Service Laboratory, Atomic Research Division, Philippine Nuclear Research Institute, Diliman, Quezon City (Philippines); Fajardo, Alejandro C.; Sabino, Noel G.; Manila-Fajardo, Analinda C. [Institute of Biological Sciences, College of Arts and Sciences, University of the Philippines, Los Banos, Laguna (Philippines); Feliciano, Chitho P., E-mail: cpfeliciano@pnri.dost.gov.ph [Microbiological Research and Service Laboratory, Atomic Research Division, Philippine Nuclear Research Institute, Diliman, Quezon City (Philippines); Institute of Biology, College of Science, University of the Philippines, Diliman, Quezon City (Philippines)

    2011-10-15

    The effectiveness of gamma radiation in inactivating the Philippine isolate of Paenibacillus larvae was investigated. Spores of P. larvae were irradiated at incremental doses (0.1, 0.2, 0.4, 0.8 and 1.6 kGy) of gamma radiation emitted by a {sup 60}Co source. Surviving spores were counted and used to estimate the decimal reduction (D{sub 10}) value. A dose of 0.2 kGy was sufficient to inactivate 90% of the total recoverable spores from an initial count of 10{sup 5}-9x10{sup 3} spores per glass plate. The sterilizing effect of high doses of gamma radiation on the spores of P. larvae in infected hives was determined. In this study, a minimum dose (D{sub min}) of 15 kGy was tested. Beehives with sub-clinical infections of AFB were irradiated and examined for sterility. All the materials were found to be free of P. larvae indicating its susceptibility to {gamma}-rays. After irradiation, there were no visible changes in the physical appearance of the hives' body, wax and frames. Thus, a dose of 15 kGy is effective enough for sterilization of AFB-infected materials. - Highlights: > We characterized Paenibacillus larvae and determined its radiation sensitivity. > We investigated the effectiveness of gamma rays in inactivating P. larvae. > Gamma radiation inactivates P. larvae. > 15 kGy is effective for the sterilization of P. larvae-infected hives. > Irradiation produces no visible changes in the hives' body, waxes and frames.

  6. PERUBAHAN KARAKTER KUANTITATIF MUCUNA PRURIENS GENERASI M1 PASCA IRRADIASI SINAR GAMMA CO-60

    Directory of Open Access Journals (Sweden)

    Yustinus Ulung Anggraito

    2015-02-01

    Full Text Available Koro benguk (Mucuna pruriens berpotensi sebagai bahan substitusi kedelai. Keragaman genetik koro benguk termasuk kategori rendah, sehingga perlu ditingkatkan keragaman genetiknya terutama pada faktor-faktor produksi. Tujuan penelitian adalah mendapatkan informasi mutasi mikro pada koro benguk generasi M1 setelah diradiasi dengan sinar gamma dari Cobalt-60. Benih koro benguk diperoleh dari Balai Pengembangan Perbenihan Tanaman Pangan dan Hortikultura (BP2TPH Ngipiksari, Sleman, Yogyakarta. Radiasi sinar gamma dilakukan di PAIR BATAN Pasar Jumat, Jakarta. Dosis radiasi gamma yang digunakan adalah 0; 25 Gy, 50 Gy; 100 Gy; 150 Gy, 200 Gy, dan 250 Gy. Eksperimen dilakukan menggunakan Rancangan Acak Kelompok (RAK. Parameter yang diamati adalah umur berbunga, jumlah polong, jumlah biji, berat 100 biji tanaman generasi M1. Data dianalisis menggunakan Anava, dilanjutkan dengan Uji Beda Nyata Duncan (DMRT. Hasil penelitian menunjukkan bahwa peningkatan dosis radiasi sinar gamma akan memperpanjang hari munculnya bunga dan berat biji, namun menurunkan jumlah polong dan jumlah biji pada tanaman generasi M1.

  7. Profitability of an Co 60 semi-industrial irradiator type Gamma Beam 651 Pt

    International Nuclear Information System (INIS)

    Cruz Z, E.

    1997-01-01

    It is described the capacity in volume of processed material by irradiation interesting interesting for the industry and how many laboratory samples can be processed. It is showed the costs of the annual processing, that is, the relation between the volume of sterilized material and his cost, this give us an idea about the profits for this type of gamma irradiators designed for low capacity, where is necessary to define the effective area of sterilization using high dose dosimetry. Also have been compared the maintenance costs, operation and salaries including monetary devaluation in function of the real production of the irradiation processing. Finally, it is remarked the objectives and essential characteristics of this semi-industrial irradiator. (Author)

  8. Nutritional balance of pigs irradiated on the hind part with 1100 rd of 60Co gamma rays

    International Nuclear Information System (INIS)

    Daburon, F.; Tricaud, Y.; Bourhoven, D.; Marion, C.

    1978-01-01

    The hind part of 10 adult miniature pigs was irradiated with 1100 rd of 60 Co gamma rays. The dietary mineral (Na, K, Ca, P), nitrogen and lipid balances of the animals were studied before and 1, 3 and 5 months after irradiation. While the classical early lesion of the intestinal mucosa recovered quite satisfactorily within one or two months, a pancreatic atrophy process developed progressively which might play a major role in the nutritional state of the pigs and thus in their survival. Concerning nutritional balance, nitrogen and sodium retention were perturbed until 5 months post-irradiation; cyanocobalamin absorption remained very low. Dry and organic matter utilization recovered nearly normal values in the 3rd ou 5th month [fr

  9. Radiation inactivation of Paenibacillus larvae and sterilization of American Foul Brood (AFB) infected hives using Co-60 gamma rays

    International Nuclear Information System (INIS)

    De Guzman, Zenaida M.; Cervancia, Cleofas R.; Dimasuay, Kris Genelyn B.; Tolentino, Mitos M.; Abrera, Gina B.; Cobar, Ma. Lucia C.; Fajardo, Alejandro C.; Sabino, Noel G.; Manila-Fajardo, Analinda C.; Feliciano, Chitho P.

    2011-01-01

    The effectiveness of gamma radiation in inactivating the Philippine isolate of Paenibacillus larvae was investigated. Spores of P. larvae were irradiated at incremental doses (0.1, 0.2, 0.4, 0.8 and 1.6 kGy) of gamma radiation emitted by a 60 Co source. Surviving spores were counted and used to estimate the decimal reduction (D 10 ) value. A dose of 0.2 kGy was sufficient to inactivate 90% of the total recoverable spores from an initial count of 10 5 -9x10 3 spores per glass plate. The sterilizing effect of high doses of gamma radiation on the spores of P. larvae in infected hives was determined. In this study, a minimum dose (D min ) of 15 kGy was tested. Beehives with sub-clinical infections of AFB were irradiated and examined for sterility. All the materials were found to be free of P. larvae indicating its susceptibility to γ-rays. After irradiation, there were no visible changes in the physical appearance of the hives' body, wax and frames. Thus, a dose of 15 kGy is effective enough for sterilization of AFB-infected materials. - Highlights: → We characterized Paenibacillus larvae and determined its radiation sensitivity. → We investigated the effectiveness of gamma rays in inactivating P. larvae. → Gamma radiation inactivates P. larvae. → 15 kGy is effective for the sterilization of P. larvae-infected hives. → Irradiation produces no visible changes in the hives' body, waxes and frames.

  10. Protective role of Hippopahe leaves against kidney damage in total body 60Co-gamma-irradiated mice

    International Nuclear Information System (INIS)

    Saini, Manu; Prasad, Jagdish; Bala, Madhu

    2012-01-01

    Hippophae rhamnoides has diverse therapeutic applications in Indian, Chinese and Tibetan medicine. Our earlier studies have shown that pretreatment with Hippophae leaf extract rendered >90% survival in mice population. The objective of this study was to investigate the role of our herbal preparation from Hippophae leaf against radiation induced kidney damage. The study was conducted with Strain 'A' male mice weighing approximately 28 ±2 g. The mice were administered Hippophae leaf extract, 30 minutes prior to 60 cobalt-gamma irradiation. The weight of kidneys and histological changes in kidney tissues at the light microscopic level were examined at 2, 5, 7, 10 and 15 days after treatment. The results showed that no significant change was observed in kidney weight after 60 cobalt-gamma irradiation. The glomerular damage in the form of glomerular sclerosis and percentage of damaged glomeruli; tubular damage in form of tubular dilations; apoptosis, and interstitial hemorrhages in renal cortex was also observed after radiation treatment. The pretreatment with Hippophae leaf extract countered most of the histological alterations induced by radiation. In comparison to radiation alone group, there was a significant decrease (p 60 cobalt gamma radiation induced damage. (author)

  11. Dosimetry characteristics of the Leksell gamma knife for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Wu, A.; Lindner, G.; Maitz, A.; Smarra, N.; Turco, R.F.; Kalend, A.M.; Lunsford, L.D.; Flickinger, J.C.; Bloomer, W.D.

    1988-01-01

    Gamma knife radiosurgery refers to the treatment procedure that delivers very high dose to a small brain lesion with 201 highly focused beams of Co-60. The hemispheric array of these multiple sources with the sizes of beams ranging from 4, 8, 14, to 18 mm makes the determination of dosimetry characteristics of the radiation field very complex. This paper describes the structures, operations, and dose characteristics of gamma knife. Dosimetry measurements were made using ion chamber, TLD, diode, and films to calibrate the dose outputs of the combination of 201 beams of 4, 8, 14, or 18 mm in diameter irradiating from various directions. Results of measured isodose distribution and dose profiles for the various diameter beams are also presented

  12. Polarised and tagged gamma-ray Ladon beams

    International Nuclear Information System (INIS)

    Babusci, D.

    1995-11-01

    The production of polarized and tagged gamma-ray beams by the backscattering of Laser light on the relativistic electrons circulating in storage rings is discussed. the main characteristic and the experimental results of the Ladon and LEGS beams are presented. The Graal beam is introduced

  13. Polarised and tagged gamma-ray Ladon beams

    Energy Technology Data Exchange (ETDEWEB)

    Babusci, D [Istituto Nazionale di Fisica Nucleare, Frascati (Italy). Lab. Nazionale di Frascati

    1995-11-01

    The production of polarized and tagged gamma-ray beams by the backscattering of Laser light on the relativistic electrons circulating in storage rings is discussed. the main characteristic and the experimental results of the Ladon and LEGS beams are presented. The Graal beam is introduced.

  14. Tl response of KMgF3 :Lu+PTFE depending on the dose of gamma radiation of 60Co

    International Nuclear Information System (INIS)

    Lopez, A.; Gonzalez, P.R.; Furetta, C.; Azorin, J; Rivera, T.; Sepulveda, F.

    2002-01-01

    Due to the great interest in Tl dosimetry for measuring the levels of radiation doses, as environmental as in the different medical radiation applications in different laboratories of the World it is continued in the searching of new Tl materials with optimum dosimetric characteristics and low cost. In this work the obtained results when irradiating Tl dosemeters of KMgF 3 :Lu + PTFE with gamma radiation of 60 Co are presented. Such results showed that this material presents linearity of response depending on the dose between 0.016 to 100 Gy. Although it is continued with the characterization tests it is able to say that this Tl new material can be used for dosimetric aims. (Author)

  15. Effect of gamma radiation of 60Co in the variability of chinese bean [Vigna unguiculata (l.) Walpers] en R4M4

    International Nuclear Information System (INIS)

    Salmeron E, J.; Bueno J, J.E.; Valencia E, F.; Cervantes S, T.; Cruz T, E. De la

    2007-01-01

    Selection of plants of Chinese bean coming from seed irradiated with gammas of 60 Co in the generation R 4 M 4 (fourth recurrent irradiation, fourth segregate generation) were carried out, taking as selection approaches the plant architecture, the numbers of sheaths for plant, sheath longitude, position of the sheaths, grain size and resistance to plagues and illnesses. 17 lines were selected for grain and 3 lines with fodder characteristics of black grain color were also obtained. (Author)

  16. Dose calculation method with 60-cobalt gamma rays in total body irradiation

    International Nuclear Information System (INIS)

    Scaff, Luiz Alberto Malaguti

    2001-01-01

    Physical factors associated to total body irradiation using 60 Co gamma rays beams, were studied in order to develop a calculation method of the dose distribution that could be reproduced in any radiotherapy center with good precision. The method is based on considering total body irradiation as a large and irregular field with heterogeneities. To calculate doses, or doses rates, of each area of interest (head, thorax, thigh, etc.), scattered radiation is determined. It was observed that if dismagnified fields were considered to calculate the scattered radiation, the resulting values could be applied on a projection to the real size to obtain the values for dose rate calculations. In a parallel work it was determined the variation of the dose rate in the air, for the distance of treatment, and for points out of the central axis. This confirm that the use of the inverse square law is not valid. An attenuation curve for a broad beam was also determined in order to allow the use of absorbers. In this work all the adapted formulas for dose rate calculations in several areas of the body are described, as well time/dose templates sheets for total body irradiation. The in vivo dosimetry, proved that either experimental or calculated dose rate values (achieved by the proposed method), did not have significant discrepancies. (author)

  17. Cell survival of human tumor cells compared with normal fibroblasts following 60Co gamma irradiation

    International Nuclear Information System (INIS)

    Lloyd, E.L.; Henning, C.B.; Reynolds, S.D.; Holmblad, G.L.; Trier, J.E.

    1982-01-01

    Three tumor cell lines, two of which were shown to be HeLa cells, were irradiated with 60 Co gamma irradiation, together with two cell cultures of normal human diploid fibroblasts. Cell survival was studied in three different experiments over a dose range of 2 to 14 gray. All the tumor cell lines showed a very wide shoulder in the dose response curves in contrast to the extremely narrow shoulder of the normal fibroblasts. In addition, the D/sub o/ values for the tumor cell lines were somewhat greater. These two characteristics of the dose response curves resulted in up to 2 orders of magnitude less sensitivity for cell inactivation of HeLa cells when compared with normal cells at high doses (10 gray). Because of these large differences, the extrapolation of results from the irradiation of HeLa cells concerning the mechanisms of normal cell killing should be interpreted with great caution

  18. Nuclear physics with advanced brilliant gamma beams at ELI–NP

    Directory of Open Access Journals (Sweden)

    Ur Călin A.

    2016-01-01

    Full Text Available The Extreme Light Infrastructure - Nuclear Physics facility is dedicated to nuclear physics studies with the use of extreme electromagnetic radiation. One of the main research system to be installed and operated in the facility is an outstanding high brilliance gamma beam system. The Gamma Beam System of ELI–NP will produce intense, quasi–monochromatic gamma beams via inverse Compton scattering of short laser pulses on relativistic electron beam pulses. The gamma beams available at ELI–NP will allow for the performance of photo-nuclear reactions aiming to reveal the intimate structure of the atomic nucleus. Nuclear Resonance Fluorescence, photo-fission, photo-disintegration reactions above the particle threshold will be used to study the dipole response of nuclei, the structure of the Pygmy resonances, nuclear processes relevant for astrophysics, production and study of exotic neutron–rich nuclei.

  19. Effect of 60 Co gamma radiation on crystalline proteins

    International Nuclear Information System (INIS)

    Bernardes, D.M.L.

    1991-01-01

    In order to study the effects of 6 0 Co gamma radiation on crystalline proteins an in vitro system was set up. For that, aqueous solutions from bovine crystalline were used irradiated with 0, 5.000, 10.000, 15.000, 20.000 and 25.000 Gy. The treatment led to protein alterations determined by different methods. By turbidimetry the formation of aggregates that increased with the radiation dose was revealed. The same observation was done from viscosity data and from the UV spectrum of the samples. From amino acid analysis and fluorimetry determinations, tryptophan appeared as the most sensitive amino acid. An increase in the free-S H-groups was also observed. After the standardization of the method, the radio modifier capability of glutathione, amino ethyl thiourea, mercapto ethyl alanine and dimethyl sulfoxide was tested. The results showed that in the presence of those substances the radiation effect was diminished. (author)

  20. Development of the 60Co gamma-ray standard field for therapy-level dosimeter calibration in terms of absorbed dose to water (ND,W)

    International Nuclear Information System (INIS)

    Fukumura, Akifumi; Mizuno, Hideyuki; Fukahori, Mai; Sakata, Suoh

    2013-01-01

    A primary standard for the absorbed dose rate to water in a 60 Co gamma-ray field was established at National Metrology Institute of Japan (NMIJ) in fiscal year 2011. Then, a 60 Co gamma-ray standard field for therapy-level dosimeter calibration in terms of absorbed dose to water was developed at National Institute of Radiological Sciences (NIRS) as a secondary standard dosimetry laboratory (SSDL). The results of an International Atomic Energy Agency (IAEA)/World Health Organization (WHO) TLD SSDL audit demonstrated that there was good agreement between NIRS stated absorbed dose to water and IAEA measurements. The IAEA guide based on the International Organization for Standardization (ISO) standard was used to estimate the relative expanded uncertainty of the calibration factor for a therapy-level Farmer type ionization chamber in terms of absorbed dose to water (N D,W ) with the new field. The uncertainty of N D,W was estimated to be 1.1% (k=2), which corresponds to approximately one third of the value determined in the existing air kerma field. The dissemination of traceability of the calibration factor determined in the new field is expected to diminish the uncertainty of dose delivered to patients significantly. (author)

  1. Ameliorative effect of salicylic acid and theophylline on photosynthetic pigment content in gamma irradiated french bean varieties, using "6"0Co as a source

    International Nuclear Information System (INIS)

    Shukla, Pradeep K.; Vishwakarma, Kapil Kumar; Shukla, Saumya; Sharma, Richa; Ramteke, P.W.; Misra, Pragati

    2017-01-01

    Irradiation of seeds may cause genetic variability that enable plant breeders to select new genotypes with improved qualitative and quantitative characteristics. An experiment was conducted to study the protective role of salicylic acid and theophylline on photosynthetic pigments of gamma exposed french bean. Seeds of four French bean were treated by different doses of gamma radiation using "6"0Co as source. The results showed that the application of salicylic acid and theophylline significantly increased chlorophyll a content, chlorophyll b content, total chlorophyll content and carotenoid content. Salicylic acid was more effective than theophylline in overcoming the radiation effects and therefore, showed more protection to the photosynthetic pigments. (author)

  2. Histological variations in liver of freshwater fish Oreochromis mossambicus exposed to 60Co gamma irradiation

    International Nuclear Information System (INIS)

    Sadiq Bukhari, A.; Syed Mohamed, H.E.; Broos, K.V.; Stalin, A.; Singhal, R.K.; Venubabu, P.

    2012-01-01

    The irradiation effect of 60 Co at the three dose level of 3 mGy, 30 mGy and 300 mGy on the histology of liver of the freshwater fish Oreochromis mossambicus was investigated. The liver of O. mossambicus was dissected out and processed for light microscopy studies. 60 Co exposed O. mossambicus were found to result in several alterations in the histoarchitecture of liver. The alterations included mild congestion of blood vessels, structural alteration, cellular swelling, vacuolation and necrotic liver cells, indicating a definite response to 60 Co irradiation. The results suggest that the liver of O. mossambicus exposed to 60 Co were structurally altered with increasing dose levels. It is to record that alteration in the liver does not affect the physiology, behaviour or lethality of the individuals. Self regulating mechanisms would have influenced the liver to remain sustained. To confirm the same further studies in the direction by increasing dose level is required. - Highlights: ► Fish Oreochromis mossambicus irradiated to the dose of 3 mGy, 30 mGy and 300 mGy. ► Histoarchitecture of liver altered with increasing dose levels of 60 Co. ► Alteration in the liver does not affect the physiology, behaviour or lethality. ► Self regulating mechanisms might have prevented from Lethality. ► HSI index value for exposed group reported ( 60 Co.

  3. Determination of the sterilizing gamma radiation dose of 60Co to ACANTHOSCELIDES OBTECTUS imagos (col. bruchidae)

    International Nuclear Information System (INIS)

    Arthur, V.; Wiendl, F.M.; Sgrillo, R.B.; Campanhola, C.

    1980-01-01

    This paper relates the results of experiments dealing with irradiation of adults of Acanthoscelides obtectus (Say, 1831). The insects were irradiated with doses of 0 (control), 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 and 20 krad gamma radiation of a 60 Co source. After irradiation, the adults were kept for observation on beans (Phaseolus vulgaris) var. Jalo, in a controlled environmen t chamber at 30 +- 1 0 C and 70 +- 5% relative humidity. Continuous weighing at weekly intervals was done 22 times, showing, by weight loss in percent, that the sterilizing dose for adults was 10,65 krad. It could also be observed that losses of less than 0,5% occured at 9 krad. For a possible employment on commercial scale, the ideal radiation dose for bean desinfestation would be 10 krad, after which no weight loss occurrence. (Author) [pt

  4. {sup 60}Co {gamma} irradiation effects on the current-voltage (I-V) characteristics of Al/SiO{sub 2}/p-Si (MIS) Schottky diodes

    Energy Technology Data Exchange (ETDEWEB)

    Tataroglu, A. [Department of Physics, Faculty of Arts and Sciences, Gazi University 06500, Ankara (Turkey)]. E-mail: ademt@gazi.edu.tr; Altindal, S. [Department of Physics, Faculty of Arts and Sciences, Gazi University 06500, Ankara (Turkey); Buelbuel, M.M. [Department of Physics, Faculty of Arts and Sciences, Gazi University 06500, Ankara (Turkey)

    2006-12-01

    It is well known that the exposure of any semiconductor surfaces to the {sup 60}Co {gamma}-ray irradiation causes electrically active defects. To investigate the effect of {gamma}-ray irradiation dose on the electrical characteristics of metal-insulator-semiconductor (MIS) Schottky diodes, the fabricated devices were exposed to {gamma} radiation at a dose of 2.12 kGy/h. The total dose range was from 0 to 450 kGy at room temperature. The density of interface states N {sub ss} as a function of E {sub ss}-E {sub v}, the values of series resistance R {sub s} and the bias dependence of the effective barrier height {phi} {sub e} for each dose were obtained from the forward bias I-V characteristics. Experimental results show that the {gamma}-irradiation gives rise to an increase in the zero bias barrier height {phi} {sub BO}, as the ideality factor n, R {sub s} and N {sub ss} decreases with increasing radiation dose.

  5. Profitability of an Co 60 semi-industrial irradiator type Gamma Beam 651 Pt; Rentabilidad de un irradiador de Cobalto 60 semi-industrial tipo Gamma beam 651 Pt

    Energy Technology Data Exchange (ETDEWEB)

    Cruz Z, E. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico. Apdo. Postal 70-51, 04510 Mexico D.F. (Mexico)

    1997-12-31

    It is described the capacity in volume of processed material by irradiation interesting interesting for the industry and how many laboratory samples can be processed. It is showed the costs of the annual processing, that is, the relation between the volume of sterilized material and his cost, this give us an idea about the profits for this type of gamma irradiators designed for low capacity, where is necessary to define the effective area of sterilization using high dose dosimetry. Also have been compared the maintenance costs, operation and salaries including monetary devaluation in function of the real production of the irradiation processing. Finally, it is remarked the objectives and essential characteristics of this semi-industrial irradiator. (Author)

  6. Multi-jump magnetic switching in ion-beam sputtered amorphous Co20Fe60B20 thin films

    International Nuclear Information System (INIS)

    Raju, M.; Chaudhary, Sujeet; Pandya, D. K.

    2013-01-01

    Unconventional multi-jump magnetization reversal and significant in-plane uniaxial magnetic anisotropy (UMA) in the ion-beam sputtered amorphous Co 20 Fe 60 B 20 (5–75 nm) thin films grown on Si/amorphous SiO 2 are reported. While such multi-jump behavior is observed in CoFeB(10 nm) film when the magnetic field is applied at 10°–20° away from the easy-axis, the same is observed in CoFeB(12.5 nm) film when the magnetic field is 45°–55° away from easy-axis. Unlike the previous reports of multi-jump switching in epitaxial films, their observance in the present case of amorphous CoFeB is remarkable. This multi-jump switching is found to disappear when the films are crystallized by annealing at 420 °C. The deposition geometry and the energy of the sputtered species appear to intrinsically induce a kind of bond orientation anisotropy in the films, which leads to the UMA in the as-grown amorphous CoFeB films. Exploitation of such multi-jump switching in amorphous CoFeB thin films could be of technological significance because of their applications in spintronic devices

  7. Comparative nephrotoxicity of native or Co-60 gamma rays irradiated crotoxin in mice

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Andre Moreira; Alves, Glaucie J.; Aires, Raquel da Silva; Turibio, Thompson O.; Thomazi, Gabriela O. Coelho; Spencer, Patrick J.; Nascimento, Nanci do, E-mail: andrerocha@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Nascimento-Rocha, Josefa M.; Magalhaes Filho, Asterio Souza, E-mail: 0304@prof.itpacporto.com.br [Instituto Tocantinense Presidente Antonio Carlos Porto (ITPAC), Porto Nacional, TO (Brazil)

    2015-07-01

    Snake venoms are complex mixtures of proteins and peptides with a wide spectrum of physiological targets such as the blood coagulation and cardiovascular systems and the motor end plate among others. Acute renal failure is a common complication in accidents with the South American rattlesnake. The toxin involved in this pathology is the crotoxin, a major component of the venom in terms of concentration and toxicity. Snake venoms, when irradiated with {sup 60}Co gamma rays present a significant decrease in toxicity while the immunogenic properties of its components are preserved. The use of irradiated venom is an attractive alternative for antisera production since it might reduce the appearance of renal lesions improving the welfare and lifespan of those animals employed on antivenom production. At the present work, we have compared the effects of native and irradiated crotoxin on the mice renal function. Tubular lesions were observed in all the samples from the animal group injected with native crotoxin. Animals injected with the irradiated toxin presented alteration only after 30 minutes and 1 hour after injection. These data suggest that the onset of the renal lesions is delayed and that the severity of the lesions might be lower when using irradiated crotoxin. (author)

  8. Comparative nephrotoxicity of native or Co-60 gamma rays irradiated crotoxin in mice

    International Nuclear Information System (INIS)

    Rocha, Andre Moreira; Alves, Glaucie J.; Aires, Raquel da Silva; Turibio, Thompson O.; Thomazi, Gabriela O. Coelho; Spencer, Patrick J.; Nascimento, Nanci do; Nascimento-Rocha, Josefa M.; Magalhaes Filho, Asterio Souza

    2015-01-01

    Snake venoms are complex mixtures of proteins and peptides with a wide spectrum of physiological targets such as the blood coagulation and cardiovascular systems and the motor end plate among others. Acute renal failure is a common complication in accidents with the South American rattlesnake. The toxin involved in this pathology is the crotoxin, a major component of the venom in terms of concentration and toxicity. Snake venoms, when irradiated with 60 Co gamma rays present a significant decrease in toxicity while the immunogenic properties of its components are preserved. The use of irradiated venom is an attractive alternative for antisera production since it might reduce the appearance of renal lesions improving the welfare and lifespan of those animals employed on antivenom production. At the present work, we have compared the effects of native and irradiated crotoxin on the mice renal function. Tubular lesions were observed in all the samples from the animal group injected with native crotoxin. Animals injected with the irradiated toxin presented alteration only after 30 minutes and 1 hour after injection. These data suggest that the onset of the renal lesions is delayed and that the severity of the lesions might be lower when using irradiated crotoxin. (author)

  9. Distribution of 60Co and 54Mn in graphite material of irradiated HTGR fuel assemblies

    International Nuclear Information System (INIS)

    Hayashi, Kimio; Kikuchi, Teruo; Kobayashi, Fumiaki; Minato, Kazuo; Fukuda, Kousaku; Ikawa, Katsuichi; Iwamoto, Kazumi

    1984-05-01

    Distribution of 60 Co and 54 Mn was measured in the graphite sleeves and blocks of the third and fourth HTGR fuel assemblies irradiated in the Oarai Gas Loop-1 (OGL-1), which is a high temperature inpile gas loop installed in the Japan Materials Testing Reactor (JMTR) of Japan Atomic Energy Research Institute (JAERI). Axial and circumferential profiles were obtained by gamma spectrometry, and radial profiles by lathe sectioning with gamma spectrometry. Distribution of 60 Co is in good agreement with that of thermal neutron flux, and the Co content in the graphite is estimated to be -- 1 x 10 -9 in weight fraction. Concentration of 54 Mn decreases toward the axial center in its axial profile, and radially is almost uniform inside and appreciably higher at free surfaces. An estimated Fe content of --10 -8 in wight fraction is smaller by two orders of magnitude than that from chemical analysis. Higher concentraion of 60 Co and 54 Mn at the free surfaces suggests the importance of transportation process of these nuclides in the coolant loop. (author)

  10. Study of the effect of the gamma radiation in polycarbonate

    International Nuclear Information System (INIS)

    Khoury, H.J.; Araujo, E.S. de; Silveira, S.V. da

    1990-01-01

    To estimate the radiation effects in the DUROLON polycarbonate, samples were irradiated with 60 Co gamma beam with doses between 0,2KGy and 50KGy. The results obtained shown variations in the yellowed index above 1KGy dose. Their mechanical proprieties are not changed at interval of this doses. (author) [pt

  11. Seed germination of peanuts irradiated with cobalt ({sup 60}CO); Germinacao de sementes de amendoim irradiadas com cobalto ({sup 60}Co)

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Niedja Marrize C.; Almeida, Francisco de Assis C.; Gomes, Josivanda P.; Pessoa, Elvira B., E-mail: niedjamarizze@yahoo.com.b, E-mail: josivanda@deag.ufcg.edu.b, E-mail: elvirabe@gmail.co [Universidade Federal de Campina Grande (UFCG), PB (Brazil). Dept. de Engenharia Agricola; Leal, Artur S. Cavalcanti, E-mail: arturcleal@yahoo.com.b [Universidade Federal de Campina Grande (UFCG), PB (Brazil). Dept. de Engenharia de Materiais

    2010-07-01

    This work was realized to evaluate the effect of gamma irradiation ({sup 60}Co) at doses 0, 0.50, 1.00, 1.50, 2.00, 2.50, 3.00 and 4.00 kGy, on germination of seeds of peanut, cultivar BR1. Irradiation Department of Nuclear, UFPE, where he received after the irradiation, they were stored in packing of PET and polyethylene braided with a time of 90 days. Through the results, obtained monthly, concluded that the dose of 0.5 kGy was effective in the germination of seeds of peanut, not affecting its power of germination and overcoming the witness within 30 to 60 days. (author)

  12. Gamma spectroscopy: from steady beams to radioactive beams

    International Nuclear Information System (INIS)

    Stezowski, O.

    2008-06-01

    The author gives an overview of his research works in the field of gamma spectroscopy. First, he recalls some results of experiments performed for the study of peculiar structures associated with different modes of nucleus rotation, and notably in the case of collective rotation of deformed and even super-deformed nuclei. Then, he details tools and methods used to experimentally determine the level scheme. The main characteristics of steady and radioactive beams are briefly presented, and their complementarities and differences are highlighted. Specific spectrometers and sensors are described. In a last chapter, the author discusses several research projects he is involved in, and more particularly the 'gamma tracking' which is the fundamental principle for gamma multi-sensors of the next generations

  13. Biochemical and pharmacological characterization of irradiated crotamine by gamma rays of {sup 60}Co; Caracterizacao bioquimica e farmacologica da crotamina irradiada por raios gama de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Karina Corleto

    2014-07-01

    The serum production in Brazil, the only effective treatment in cases of snakebites, uses horses that although large size, have reduced l lifespan compared with horses not immunized. Ionizing radiation has been shown as an excellent tool in reducing the toxicity of venoms and toxins isolated, and promote the achievement of better immunogens for serum production, and contributing to the welfare of serum-producing animals. It is known, however, that the effects of ionizing radiation on protein are characterized by various chemical modifications, such as fragmentation, cross-linking due to aggregation and oxidation products generated by water radiolysis. However, the action of gamma radiation on toxins is not yet fully understood structurally and pharmacologically, a fact that prevents the application of this methodology in the serum production process. So we proposed in this paper the characterization of crotamine, an important protein from the venom of Crotalus durissus terrificus species, irradiated with {sup 60}Co gamma rays. After isolating the toxin by chromatographic techniques and testing to prove the obtaining of pure crotamine, it was irradiated with gamma rays and subjected to structural analysis, Fluorescence and Circular Dichroism. Using high hydrostatic pressure tests were also conducted in order to verify that the conformational changes caused by radiation suffer modifications under high pressures. From the pharmacological point of view, muscle contraction tests were conducted with the objective of limiting the action of crotamine in smooth muscle as well as the change in the action of toxin caused structural changes to the front. Analysis of Circular Dichroism and Fluorescence showed changes in structural conformation of crotamine when subjected to gamma radiation and that such changes possibly occurring in the secondary and tertiary structure of the protein. The observed in pharmacological tests showed that the irradiated crotamine was less effective

  14. Effect of gamma radiation of {sup 60}Co in the variability of chinese bean [Vigna unguiculata (l.) Walpers] en R{sub 4}M{sub 4}; Efecto de la radiacion gamma de {sup 60}Co en la variabilidad de frijol chino [Vigna unguiculata (l.) Walpers] en R{sub 4}M{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Salmeron E, J.; Bueno J, J.E.; Valencia E, F. [CSAEGro, Iguala, Guerrero, Tel and Fax 01 733 (33) 24328 (Mexico); Cervantes S, T. [IREGEP (Mexico); Cruz T, E. De la [ININ, Departamento de Biologia, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: csaegro@prodigy.net.mx

    2007-07-01

    Selection of plants of Chinese bean coming from seed irradiated with gammas of {sup 60}Co in the generation R{sub 4}M{sub 4} (fourth recurrent irradiation, fourth segregate generation) were carried out, taking as selection approaches the plant architecture, the numbers of sheaths for plant, sheath longitude, position of the sheaths, grain size and resistance to plagues and illnesses. 17 lines were selected for grain and 3 lines with fodder characteristics of black grain color were also obtained. (Author)

  15. Effect of Co-60 gamma irradiated chitosan and phosphorus fertilizer on growth, yield and trigonelline content of Trigonella foenum-graecum L.

    Directory of Open Access Journals (Sweden)

    Tariq Ahmad Dar

    2015-07-01

    Full Text Available Natural marine polysaccharides such as chitosan, sodium alginate and carrageenan; after depolymerization by different techniques, have shown promising plant growth promoting and other biological activities. Chitosan after irradiation with Co-60 gamma-rays have proven to be a miraculous plant growth promoter in different plants. Trigonelline; an anti-diabetic compound is obtained mainly from the seeds of Fenugreek (Trigonella foenum-graecum L.. Trigonelline counteracts diabetes mellitus (DM through the operation of the mechanisms of insulin secretion, modulation of β-cell regeneration and stimulation of activity of glucose metabolism related enzymes. Considering the medicinal importance a pot experiment was conducted to investigate the effect of foliar application of Co-60 gamma irradiated chitosan (IC with soil applied phosphorus supplement on growth, biochemical and quality attributes of fenugreek. Four concentrations of irradiated chitosan were used (0, 40, 80 and 120 mg L−1 individually as well as in combination with single dose of phosphorus 40 kg ha−1. Un-irradiated chitosan (UN 40 mg L−1 and de-ionized water were used as control. IC significantly affected almost all the parameters including seed yield, trigonelline content and trigonelline yield. There were 10 treatments and among all, P40 + IC 40 mg L−1 proved to be the best, which increased total alkaloid content by 34.9%, seed yield by 125.4%, and trigonelline content by 17.8%. Contents of photosynthetic pigments and activity of nitrate reductase, carbonic anhydrase enzymes were also significantly enhanced.

  16. Dose rate distribution of the GammaBeam: 127 irradiator using MCNPX code

    International Nuclear Information System (INIS)

    Gual, Maritza Rodriguez; Batista, Adriana de Souza Medeiros; Pereira, Claubia; Faria, Luiz O. de; Grossi, Pablo Andrade

    2013-01-01

    The GammaBeam - 127 Irradiator is widely used for biological, chemical and medical applications of the gamma irradiation technology using Cobalt 60 radioactive at the Centro de Desenvolvimento da Tecnologia Nuclear CDTN/CNEN, Belo Horizonte, Brazil. The source has maximum activity of 60.000Ci, which is composed by 16 double encapsulated radioactive pencils placed in a rack. The facility is classified by the IAEA as Category II (dry storage facility). The aim of this work is to present a modelling developed to evaluate the dose rates at the irradiation room and the dose distribution at the irradiated products. In addition, the simulations could be used as a predictive tool of dose evaluation in the irradiation facility helping benchmark experiments in new similar facilities. The MCNPX simulated results were compared and validated with radiometric measurements using Fricke and TLDs dosimeters along several positions inside the irradiation room. (author)

  17. (60)Co in cast steel matrix: A European interlaboratory comparison for the characterisation of new activity standards for calibration of gamma-ray spectrometers in metallurgy.

    Science.gov (United States)

    Tzika, Faidra; Burda, Oleksiy; Hult, Mikael; Arnold, Dirk; Marroyo, Belén Caro; Dryák, Pavel; Fazio, Aldo; Ferreux, Laurent; García-Toraño, Eduardo; Javornik, Andrej; Klemola, Seppo; Luca, Aurelian; Moser, Hannah; Nečemer, Marijan; Peyrés, Virginia; Reis, Mario; Silva, Lidia; Šolc, Jaroslav; Svec, Anton; Tyminski, Zbigniew; Vodenik, Branko; Wätjen, Uwe

    2016-08-01

    Two series of activity standards of (60)Co in cast steel matrix, developed for the calibration of gamma-ray spectrometry systems in the metallurgical sector, were characterised using a European interlaboratory comparison among twelve National Metrology Institutes and one international organisation. The first standard, consisting of 14 disc shaped samples, was cast from steel contaminated during production ("originally"), and the second, consisting of 15 similar discs, from artificially-contaminated ("spiked") steel. The reference activity concentrations of (60)Co in the cast steel standards were (1.077±0.019) Bqg(-1) on 1 January 2013 12h00 UT and (1.483±0.022) Bqg(-1) on 1 June 2013 12h00 UT, respectively. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Effects of gamma radiation on phases of evolutional cycle of Corcyra cephalonica (Stainton, 1865) (Lepidoptera pyralidae) in artificial diet

    International Nuclear Information System (INIS)

    Aguilar, J.A.D.

    1991-04-01

    The effects of the increase in the gamma radiation ( 60 Co) doses on different phases of the evolutional cycle of Corcyra cephalonica (Stainton, 1865) (Lepidoptera Pyraliade) are studied. A cobalt 60 source type gamma beam 650 was used and the activity was of approximately 2.91 x 10 14 Bq. The experiments were conducted under controlled conditions with temperature at 25 ± 2 0 C and relative humidity of 70 ± 10%. (M.A.C.)

  19. Comparison of the standards of absorbed dose to water of the VNIIFTRI, Russia and the BIPM for {sup 60}Co {gamma} rays

    Energy Technology Data Exchange (ETDEWEB)

    Allisy-Roberts, P.J.; Burns, D.T. [Bureau International des Poids et Mesures (BIPM), 92 - Sevres (France); Berlyand, V.; Bregadze, Y.; Korostin, S. [All-Russian Scientific Research Institute for Physical-Technical and Radiotechnical Measurements, Moscow (Russian Federation)

    2003-09-15

    A comparison of the standards of absorbed dose to water of the All-Russian Scientific Research Institute for Physical-Technical and Radio-technical Measurements (VNIIFTRI), Russia and of the Bureau International des Poids et Mesures (BIPM) has been made in {sup 60}Co gamma radiation. The results show that the VNIIFTRI and the BIPM standards for absorbed dose to water are in agreement, yielding a mean ratio of 0.9967 for the calibration factors of the transfer chambers, the difference from unity being within the combined standard uncertainty (0.0043) for this result. (authors)

  20. Evaluation of gamma radiation (60-Co) induced mutation in two Phaseolus vulgaris varieties

    International Nuclear Information System (INIS)

    Silva, R.M.

    1984-01-01

    Two varieties of Phaseolus vulgaris (Jutiapan and San Martin) were irradiated at 0, 8, 15, 20 and 30 kR doses in a 60-cobalt gamma source, to identify mutants and 20% lethality. M 2 plants showing morphogical mutations were selected. Differences in sensitivity to irradiation of the two varieties were noted, using data and physiological effects of M 1 . Selection and analysis for protein content were in M 3 as well as hereditary changes. (M.A.C.) [pt

  1. Study of radiation detectors response in standard X, gamma and beta radiation standard beams; Estudo da resposta de monitores de radioprotecao em feixes padronizados de radiacao X, gama e beta

    Energy Technology Data Exchange (ETDEWEB)

    Nonato, Fernanda Beatrice Conceicao

    2010-07-01

    The response of 76 Geiger-Mueller detectors, 4 semiconductor detectors and 34 ionization chambers were studied. Many of them were calibrated with gamma radiation beams ({sup 37}Cs and {sup 60}Co), and some of them were tested in beta radiation ({sup 90}Sr+{sup 9'}0Y e {sup 204}Tl) and X radiation (N-60, N-80, N-100, N-150) beams. For all three types of radiation, the calibration factors of the instruments were obtained, and the energy and angular dependences were studied. For beta and gamma radiation, the angular dependence was studied for incident radiation angles of 0 deg and +- 45 deg. The curves of the response of the instruments were obtained over an angle interval of 0 deg to +- 90 deg, for gamma, beta and X radiations. The calibration factors obtained for beta radiation were compared to those obtained for gamma radiation. For gamma radiation, 24 of the 66 tested Geiger-Mueller detectors presented results for the energy dependence according to international recommendation of ISO 4037-2 and 56 were in accordance with the Brazilian ABNT 10011 recommendation. The ionization chambers and semiconductors were in accordance to national and international recommendations. All instruments showed angular dependence less than 40%. For beta radiation, the instruments showed unsatisfactory results for the energy dependence and angular dependence. For X radiation, the ionization chambers presented results for energy dependence according to the national recommendation, and the angular dependence was less than 40%. (author)

  2. Study of radiation detectors response in standard X, gamma and beta radiation standard beams; Estudo da resposta de monitores de radioprotecao em feixes padronizados de radiacao X, gama e beta

    Energy Technology Data Exchange (ETDEWEB)

    Nonato, Fernanda Beatrice Conceicao

    2010-07-01

    The response of 76 Geiger-Mueller detectors, 4 semiconductor detectors and 34 ionization chambers were studied. Many of them were calibrated with gamma radiation beams ({sup 37}Cs and {sup 60}Co), and some of them were tested in beta radiation ({sup 90}Sr+{sup 9'}0Y e {sup 204}Tl) and X radiation (N-60, N-80, N-100, N-150) beams. For all three types of radiation, the calibration factors of the instruments were obtained, and the energy and angular dependences were studied. For beta and gamma radiation, the angular dependence was studied for incident radiation angles of 0 deg and +- 45 deg. The curves of the response of the instruments were obtained over an angle interval of 0 deg to +- 90 deg, for gamma, beta and X radiations. The calibration factors obtained for beta radiation were compared to those obtained for gamma radiation. For gamma radiation, 24 of the 66 tested Geiger-Mueller detectors presented results for the energy dependence according to international recommendation of ISO 4037-2 and 56 were in accordance with the Brazilian ABNT 10011 recommendation. The ionization chambers and semiconductors were in accordance to national and international recommendations. All instruments showed angular dependence less than 40%. For beta radiation, the instruments showed unsatisfactory results for the energy dependence and angular dependence. For X radiation, the ionization chambers presented results for energy dependence according to the national recommendation, and the angular dependence was less than 40%. (author)

  3. The effect of perinatal 60Co gamma radiation on brain weight in beagles

    International Nuclear Information System (INIS)

    Hamilton, B.F.; Benjamin, S.A.; Angleton, G.M.; Lee, A.C.

    1989-01-01

    Beagle dogs were given single, whole-body 60 Co gamma-radiation exposures at one of three prenatal (8, 28, or 55 days postcoitus) or three postnatal (2, 70, or 365 days postpartum) ages to evaluate the relative radiosensitivity of various stages of brain development. A total of 387 dogs received mean doses ranging from 0.16 to 3.83 Gy, and 120 dogs were sham-irradiated. Groups of dogs were sacrificed at preselected times from 70 days to 11 years of age. Brain weight decreased significantly with increasing dose in dogs irradiated at 28 or 55 days postcoitus or at 2 days postpartum. Irradiations at 28 days postcoitus were dramatically more effective in causing a reduction in brain weight than those at 55 days postcoitus or 2 days postpartum. Among dogs given 1.0 Gy or more and followed for up to 4 years, there was a radiation effect evident at all three sensitive exposure ages. Among dogs given lower doses and followed for up to 11 years, there was a significant decrease in brain weight in dogs given 0.80-0.88 Gy at 28 days postcoitus. All decreases in brain weight were present after normalization for radiation-induced reductions in skeletal (body) size. No specific morphologic changes were noted in the brains which showed the radiation-related reductions in size

  4. Seed germination of peanuts irradiated with cobalt (60CO)

    International Nuclear Information System (INIS)

    Alves, Niedja Marrize C.; Almeida, Francisco de Assis C.; Gomes, Josivanda P.; Pessoa, Elvira B.; Leal, Artur S. Cavalcanti

    2010-01-01

    This work was realized to evaluate the effect of gamma irradiation ( 60 Co) at doses 0, 0.50, 1.00, 1.50, 2.00, 2.50, 3.00 and 4.00 kGy, on germination of seeds of peanut, cultivar BR1. Irradiation Department of Nuclear, UFPE, where he received after the irradiation, they were stored in packing of PET and polyethylene braided with a time of 90 days. Through the results, obtained monthly, concluded that the dose of 0.5 kGy was effective in the germination of seeds of peanut, not affecting its power of germination and overcoming the witness within 30 to 60 days. (author)

  5. Dosimetry of a gamma beam - 650 60Co irradiator. 3. Mapping of the isodose curves in the internal cavity

    International Nuclear Information System (INIS)

    Escobedo, J.F.; Nascimento Filho, V.F. do; Ferraz, E.S.B.

    1981-01-01

    The Gammabeam-650 60 Co irradiator, containing 29,080 curies (April 1 sup(st), 1974), made by Atomic Energy of Canada Limited and in operation at CENA - Piracicaba, Sao Paulo, Brazil, basically has a block of lead for storage and shielding of the radioactive capsules and 12 vertical pneumatic tubes to maintain them in exposure position. These tubes form a cylindrical internal cavity with varying diameter between 10 and 84 cm. The isodose curves were determined for the geometries of 3, 6 and 12 actives tubes and 42 and 84 cm of diameter using the Fricke's chemical dosimeter. (Author) [pt

  6. Report on EUROMET.RI(I)-K1 and EUROMET.RI(I)-K4 (EUROMET project no. 813): Comparison of air kerma and absorbed dose to water measurements of 60Co radiation beams for radiotherapy

    International Nuclear Information System (INIS)

    Csete, I.; Leiton, A.G.; Sochor, V.; Lapenas, A.; Grindborg, J.E.; Jokelainen, I.; Bjerke, H.; Dobrovodsky, J.; Megzifene, A.; Hourdakis, C.J.; Ivanov, R.; Vekic, B.; Kokocinski, J.; Cardoso, J.; Buermann, L.; Tiefenboeck, W.; Stucki, G.; Van Dijk, E.; Toni, M.P.; Minniti, R.; McCaffrey, J.P.; Silva, C.N.M.; Kharitonov, I.; Webb, D.; Saravi, M.; Delaunay, F.

    2010-01-01

    The results of an unprecedented international effort involving 26 countries are reported. The EUROMET.RI(I)-K1 and EUROMET.RI(I)-K4 key comparisons were conducted with the goal of supporting the relevant calibration and measurement capabilities (CMC) planned for publication by the participant laboratories. The measured quantities were the air kerma (K air ) and the absorbed dose to water (Dw) in 60 Co radiotherapy beams. The comparison was conducted by the pilot laboratory MKEH (Hungary), in a star-shaped arrangement from January 2005 to December 2008. The calibration coefficients of four transfer ionization chambers were measured using two electrometers. The largest deviation between any two calibration coefficients for the four chambers in terms of air kerma and absorbed dose to water was 2.7% and 3.3% respectively. An analysis of the participant uncertainty budgets enabled the calculation of degrees of equivalence (DoE), in terms of the deviations of the results and their associated uncertainties. As a result of this EUROMET project 813 comparison, the BIPM key comparison database (KCDB) will include eleven new Kair and fourteen new D w DoE values of European secondary standard dosimetry laboratories (SSDLs), and the KCDB will be updated with the new DoE values of the other participant laboratories. The pair-wise degrees of equivalence of participants were also calculated. In addition to assessing calibration techniques and uncertainty calculations of the participants, these comparisons enabled the experimental determinations of N Dw /N Kair ratios in the 60 Co gamma radiation beam for the four radiotherapy transfer chambers. (authors)

  7. Radiation degradation of marine polysaccharides by low energy electron beam

    International Nuclear Information System (INIS)

    Yoshii, Fumio; Nagasawa, Naotsugu; Kume, Tamikazu

    2003-01-01

    The radiation degradations of marine polysaccharides by both gamma Co-60 and electron beam irradiations are investigated. Polysaccharides and oligosaccharides can be produced by degradation of corresponding polysaccharides including marine polysaccharides such as alginates, chitin chitosan and carrageenan. The viscosity of alginate, chitosan and carrageenan solution decreases markedly with increase of the low energy electron beam irradiation time and the beam current. Furthermore, the viscosity is reduced sharply in short time for polysaccharide solution with low concentration, for instance carrageenan solution of 1%. (author)

  8. Use of 60 Co gamma radiation to expend the shell life of packaged sliced loaves

    International Nuclear Information System (INIS)

    Nazato, R.E.S.

    1991-11-01

    The evaluation of conservation of sliced loaves (bread cut into slices). baked by five bakeries of Piracicaba, after gamma irradiation and maintained into polyethylene begs of low density, of 47,5 and 85 μm of thicknesses is shown. The sliced loaves were put into the bags and thermo-sealed by hand, like they were handled by the bakers. After this, they were irradiated with doses of 0.0: 2.0; 4.0; 6.0; 8.0 and 10.0 kGy of gamma radiation in a irradiation chamber of Cobalt-60 at a dose rate of 2,68 kGy per hour, at the room temperature (28 0 C). After irradiation the samples were maintained under at the room temperature (26 - 34 0 C), and humidity, as similar as possible to the conditions of the markets, bakeries and shops they were sold. The samples were evaluated every days and if any of them presented sign of contamination. It was threw away because it was inappropriate for human consumption. (author)

  9. Re-evaluation of 60Co treatment facility of Korle-Bu Teaching Hospital

    International Nuclear Information System (INIS)

    Adu, S.

    2008-06-01

    The radiological protection assessment based on the shielding of the Co-60 Radiotherapy facility at the Korle Bu Teaching Hospital after the source replacement has been carried out. The results indicate that the concrete biological shield is adequate to attenuate the gamma photons from the new 222 TBq Co-60 source in use. The dose rates at critical locations of the public access area are within the recommended dose rate limit of O.5J..1Sv/h and 7.5J..1Sv/h for public and staff respectively. Thus the shielding has not deteriorated and still provides adequate protection for members of the public and the operating staff (au).

  10. Study on gamma and electron beam sterilization of third generation cephalosporins cefdinir and cefixime in solid state

    International Nuclear Information System (INIS)

    Singh, Babita K.; Parwate, Dilip V.; Das Sarma, Indrani B.; Shukla, Sudhir K.

    2010-01-01

    The effect of gamma radiation from 60 Co source and 2 MeV e-beam was studied on two thermolabile cephalosporin antibiotics viz cefdinir and cefixime in solid state. The parameters studied to assess radiolytic degradation were loss of chemical and microbiological potency, change in optical rotation, electronic and vibrational absorption characteristics, thermal behavior and color modification. ESR spectroscopic study, HPLC related impurity profile, thermogram and Raman spectrum are applied in deducing the nature of radiolytic impurities and their formation hypotheses. Cefixime is radiation sensitive, whereas cefdinir has acceptable radiation resistance at 25 kGy dose. The nature of radiolytic related impurities and their concentrations indicates that the lactam ring is not highly susceptible to direct radiation attack, which otherwise is considered very sensitive to stress (thermal, chemical and photochemical).

  11. Study on gamma and electron beam sterilization of third generation cephalosporins cefdinir and cefixime in solid state

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Babita K., E-mail: singhbab2001@rediffmail.co [Department of Chemistry, RTM Nagpur University Campus, Amravati Road, Nagpur 440033 (India); Parwate, Dilip V. [Department of Chemistry, RTM Nagpur University Campus, Amravati Road, Nagpur 440033 (India); Das Sarma, Indrani B. [Jhulelal Institute of Technology, Nagpur (India); Shukla, Sudhir K. [Central Forensic Science Laboratory, Chandigarh (India)

    2010-10-15

    The effect of gamma radiation from {sup 60}Co source and 2 MeV e-beam was studied on two thermolabile cephalosporin antibiotics viz cefdinir and cefixime in solid state. The parameters studied to assess radiolytic degradation were loss of chemical and microbiological potency, change in optical rotation, electronic and vibrational absorption characteristics, thermal behavior and color modification. ESR spectroscopic study, HPLC related impurity profile, thermogram and Raman spectrum are applied in deducing the nature of radiolytic impurities and their formation hypotheses. Cefixime is radiation sensitive, whereas cefdinir has acceptable radiation resistance at 25 kGy dose. The nature of radiolytic related impurities and their concentrations indicates that the lactam ring is not highly susceptible to direct radiation attack, which otherwise is considered very sensitive to stress (thermal, chemical and photochemical).

  12. Molecular exclusion chromatographic analysis on 60Co irradiated rattlesnake

    International Nuclear Information System (INIS)

    Murata, Y.; Rogero, J.R.

    1988-07-01

    Ionizing radiations are sufficiently energetic to be able of breaking chemical bonds and as result of that molecules of substances present in the irradiated will be chemically changed and their biological properties affected also. In this paper the effects of gamma radiation of Co-60 on the rattlesnake venom were studied. A pool of positive crotamina Crotalus durissus terrificus venom was dissolved in 0,15 M NaCl and irradiated with Co-60. Doses of 100, 250, 500, 750, 1500 and 2000 Gy were applied at the dose rate of 1190 Gy/h. With doses over 500 Gy the solutions became turbid, suggesting the presence of aggregates and structural changes of the proteins. The concentration of proteins from the filtered solution was measured by the Lowry method. One ml samples were measured at 230 nm. The partition coefficients and the areas of the three main fraction obtained were calculated. (author) [pt

  13. Study of gamma radiation from 60Co effects on Apis mellifera venom: biochemical, pharmacological and immunological aspects

    International Nuclear Information System (INIS)

    Costa, Helena

    2001-01-01

    Africanized honeybees are very common insects in Brazil and frequently cause accidents followed by important immunological reactions and even deaths. Their venoms are composed of a complex mixture of substances of general biological actions. Ionizing radiation is able to modify molecular structures affecting the biological properties of proteins. It decreases toxic and enzymatic activities and so, it appears promising as a venom detoxification tool. The main objective of this work was to study the effects of gamma radiation on bee venom, regarding biochemical, pharmacological and immunological aspects. Africanized Apis mellifera whole venom (2 mg/ml) in 0.15 M NaCl solution was irradiated with 2 kGy in a 60 Co source. Native and irradiated bee venoms were submitted to high performance size exclusion chromatography (Tosohaas G2000SW column), high performance reversed phase chromatography in a C-18 column under water/acetonitrile gradient, SDS-PAGE. For both venoms studies have been carried out in UV absorption spectrum, protein concentration, hemolytic activity, and PLA 2 activity analysis, lethality assay (LD 50 ). Biodistribution studies was carried out after labelling native and irradiated bee venom with 99m Tc. The results showed that gamma radiation did not change the protein concentration nor its immunogenicity, although it could be observed that irradiated bee venom UV spectrum and SDS-PAGE profile presented differences when compared to native bee venom. This suggests that some structural alterations in bee venom components could have occurred after irradiation. HPLC-RP profiles showed that gamma radiation could have caused conformational changes, such as unfolding of molecule chains, changing their hydrophobic groups exposuring. The hemolytic and the PLA 2 activities of irradiated bee venom were smaller than the native ones. The gamma radiation diminished the toxicity of bee venom, but did not abolish its bioactivity, like hemolysis. Biodistribution studies

  14. Radiography of Co-60 in the lead cube castings

    International Nuclear Information System (INIS)

    Djoli Soembogo; Harun Al Rasyid R; Namad Sianta

    2016-01-01

    Radiography Co-60 on Carbon steel or Stainless steel has been widely applied, but for metal Lead has not yet been applied and has not yet widely known. Lead has a greater density than Carbon steel or Stainless steel and could muffle gamma radiation so it takes a longer exposure time. The result of its film radiography are also not as good as compared to radiography applications on carbon steel or Stainless steel. The study also applied digital radiography using isotope Co-60 sources and used Epson V700 scanner positive film for digitization results of conventional radiographic films. These radiographs using film AGFA D7 to get the contrast medium, medium sensitivity and good image quality. The purpose of radiography Co-60 on the cube castings Lead is to find indications of defective castings cube Lead and digitizing the results using conventional radiographic film with a positive film media scanner to process the data transfer and storage of digital data. Radiographic testing has been carried out using the isotope Co-60 on metal castings Lead with a single thickness of a single shadow method using positive film scanner media and isotope Co-60 with disabilities observation parameter Lead metal castings on radiographic film. Co-60 radiation time exposure is 3,500 hours for the thickness of the metal cube castings Lead 100 mm with the activity of 29 Ci and perpendicular SFD of 840 mm. Radiographic testing on metal cube castings Lead by the method of a single thickness of single image defects produce a parameter indicative for a cube of metal castings Lead of porosity level 2. The density mean of radiographic film was 2.051 and 2.046 for 5 minutes in a developer solution. The result of scanning positive film is in the form of digital radiography which allows for the transfer of digital data or computerized storage of digital data. This status is still within limits acceptable under the standards referred. (author)

  15. Evaluation of an ionization chamber response at small distances during dosimetry of gamma radiation beams

    Energy Technology Data Exchange (ETDEWEB)

    Afonso, Luciana C.; Potiens, Maria da Penha A.; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: lafonso@ipen.br; mppalbu@ipen.br; lcaldas@ipen.br

    2007-07-01

    The beam dosimetry measurements of a gamma irradiator, utilized for calibration of mainly portable radiation monitors, at the Calibration Laboratory of IPEN, have been taken between the source-instrument distance of 1 m and 4 m. Due to the source decay and instruments with higher dose rate ranges, calibrations at distances smaller than 1 m are necessary. For this purpose, a 30 cm{sup 3} ionization chamber calibrated against a secondary standard system was utilized. The use of this chamber is appropriate, because it can be totally irradiated. The behavior of this ionization chamber was studied in terms of: repeatability, stability and current leakage, using a {sup 90}Sr+{sup 90}Y source. The repeatability test presented uncertainties lower than {+-}0.5%. Analyzing the stability results, the variation did not exceed {+-}1.0%. The current leakage did not exceed 0.5% of the reference value. The measurements at the irradiator beams were taken at smaller distances than 1 m (in steps of 10 cm). The distance square inverse law was verified for both {sup 137}Cs and {sup 60}Co sources; the variations did not exceed {+-}5%, according to the ISO 4037-1 standard. (author)

  16. Evaluation of an ionization chamber response at small distances during dosimetry of gamma radiation beams

    International Nuclear Information System (INIS)

    Afonso, Luciana C.; Potiens, Maria da Penha A.; Caldas, Linda V.E.

    2007-01-01

    The beam dosimetry measurements of a gamma irradiator, utilized for calibration of mainly portable radiation monitors, at the Calibration Laboratory of IPEN, have been taken between the source-instrument distance of 1 m and 4 m. Due to the source decay and instruments with higher dose rate ranges, calibrations at distances smaller than 1 m are necessary. For this purpose, a 30 cm 3 ionization chamber calibrated against a secondary standard system was utilized. The use of this chamber is appropriate, because it can be totally irradiated. The behavior of this ionization chamber was studied in terms of: repeatability, stability and current leakage, using a 90 Sr+ 90 Y source. The repeatability test presented uncertainties lower than ±0.5%. Analyzing the stability results, the variation did not exceed ±1.0%. The current leakage did not exceed 0.5% of the reference value. The measurements at the irradiator beams were taken at smaller distances than 1 m (in steps of 10 cm). The distance square inverse law was verified for both 137 Cs and 60 Co sources; the variations did not exceed ±5%, according to the ISO 4037-1 standard. (author)

  17. Dosimetric properties of dysprosium doped calcium magnesium borate glass subjected to Co-60 gamma ray

    Energy Technology Data Exchange (ETDEWEB)

    Omar, R. S., E-mail: ratnasuffhiyanni@gmail.com; Wagiran, H., E-mail: husin@utm.my; Saeed, M. A. [Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 Johor Bahru (Malaysia)

    2016-01-22

    Thermoluminescence (TL) dosimetric properties of dysprosium doped calcium magnesium borate (CMB:Dy) glass are presented. This study is deemed to understand the application of calcium as the modifier in magnesium borate glass with the presence of dysprosium as the activator to be performed as TL dosimeter (TLD). The study provides fundamental knowledge of a glass system that may lead to perform new TL glass dosimetry application in future research. Calcium magnesium borate glass systems of (70-y) B{sub 2}O{sub 3} − 20 CaO – 10 MgO-(y) Dy{sub 2}O{sub 3} with 0.05  mol % ≤ y ≤ 0.7  mol % of dyprosium were prepared by melt-quenching technique. The amorphous structure and TL properties of the prepared samples were determined using powder X-ray diffraction (XRD) and TL reader; model Harshaw 4500 respectively. The samples were irradiated to Co-60 gamma source at a dose of 50 Gy. Dosimetric properties such as annealing procedure, time temperature profile (TTP) setting, optimization of Dy{sub 2}O{sub 3} concentration of 0.5 mol % were determined for thermoluminescence dosimeter (TLD) reader used.

  18. Investigation of Chitosan for Decorporation of 60Co in the Rat

    International Nuclear Information System (INIS)

    Levitskaia, Tatiana G.; Creim, Jeffrey A.; Curry, Terry L.; Luders, Teresa; Morris, James E.; Sinkov, Sergey I.; Woodstock, Angela D.; Thrall, Karla D.

    2009-01-01

    Purpose: The reported investigation is a part of our on-going research aimed at identifying effective in vivo non-toxic decorporation agents and developing new therapies to treat internal contamination with radionuclides. The non-toxic nature of chitosan makes it an especially attractive candidate for unsupervised treatment of the general population in case of radiological/nuclear emergency. In this study, chemically unmodified water-soluble chitosan oligosaccharide of low molecular weight was tested for decorporation of cobalt-60 (Co-60) using a rodent model. Methods: Affinity of chitosan oligosaccharide for Co(II) was tested in vitro under conditions of physiological pH range and ionic strength using combined spectrophotometric and potentiometric titration techniques. Fisher F344 rat model was used for in vivo studies. To evaluate effect of chitosan on ingested Co-60, animals received single oral dose of Co-60 chloride (7-13.2 kBq per animal) followed by oral administration of chitosan material (288-366 mg per kg body weight); chitosan dosing was repeated in 24 hours. Chitosan was also tested for removal of internalized Co-60. In this study, Co-60 single intravenous injection (7-8 kBq per animal) was followed by repetitive oral (300 mg per kg body weight) or intravenous (195 mg per kg body weight) administration of the chitosan material once daily for 5 days. Control animal groups received a single dose of Co-60 without chelator treatment. Excreta was collected daily. Tissues were collected postmortem and analyzed for radioactivity by gamma counting technique. Results: In vitro experiments confirmed binding of Co(II) by chitosan oligosaccharide, formation of mixed cobalt-chitosan-hydroxide complex species was proposed, and stability constants was calculated. Control in vivo studies indicated that about 71% of ingested Co-60 was excreted in two days predominantly through the gastrointestinal tract. For intravenously administered Co-60, urinal excretion was

  19. Comparison of the standards of air kerma of the OMH and the BIPM for 60Co gamma radiation

    International Nuclear Information System (INIS)

    Allisy-Roberts, P.J.; Kessler, C.; Burns, D.T.; Roger, P.; Machula, G.; Csete, I.; Rabus, H.

    2006-09-01

    A direct comparison between the standards for air kerma of the Orszagos Meresugyi Hivatal (OMH) and of the Bureau International des Poids et Mesures (BIPM) has been carried out in the 60 Co radiation beams of the BIPM. The result, expressed as a ratio of the OMH and the BIPM standards for air kerma, indicates a relative difference of 10.9 x 10 -3 with a combined standard uncertainty of 2.2 x 10 -3 . This new result agrees at the level of 0.4 x 10 -3 with the earlier direct comparisons performed in 1986 and 1994, as modified in 2001 by the application of wall and axial non-uniformity correction factors, calculated for the OMH standards using the Monte Carlo method. (authors)

  20. Sensitivity of watermelon variety Bojura to mutant agents 60Co and EMS

    Directory of Open Access Journals (Sweden)

    Nikolay Velkov

    2016-04-01

    Full Text Available A study on the sensitivity of watermelon variety Bojura to mutagenic agents was carried out in 2013-2014. The goal was to establish effective doses for mutagenic treatment of dry seeds with 60Co gamma rays (80, 100, 200, 250, 350 and 450 Gy and swollen seeds with water for 24 hours were treated with ethyl methanesulfonate (EMS at a concentration of 2%. Dominant mutations were not observed in the M1 generation. Morphological changes in 14 of 1395 M2 plants were observed. Phenotypic variations changes were the colour of the seed coat, chlorophyll disorders of cotyledons, leaves, petals, and alterations of the location of the fruit set in the central stem. Visible changes of the morphological characteristics of the fruit were not observed. The doses induced certain morphological changes, however, higher doses or combined gamma rays 60Co and EMS treatments would induce mutations more efficiently. Subsequent experiments are required to obtain mutants with changes that affect flowers and fruits. The results are important for increasing mutation efficiency in watermelon breeding.

  1. Simulation on a limited angle beam gamma ray tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jung, Sung Hee; Moon, Jin Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    Limited angle beam tomography was introduced in the medical field more than two decades ago, where it was mainly used for cardiovascular diagnostics. Later, it was also used to trace multiphase flows. In these studies, the detection systems were fixed and a scanning electron beam was rapidly swept across an xray target using deflection coils. Thus very fast scanning was possible in these studies, but their geometry resulted in a heavy and bulky system because of a complex control system and vacuum tube. Because of its heavy hardware, limited angle beam tomography has remained as indoor equipment. If the source section is replaced by a gamma ray source, limited angle beam tomography will have a very light source device. In addition, limited angle beam tomography with a gamma ray source can be designed using an open type portable gantry because it does not need a vacuum guide for an electron beam. There is a lot of need for a portable tomographic system but so far no definitive solution has been created. The inspection of industrial on-line pipes, wood telephone poles, and cultural assets are some application areas. This study introduces limited angle beam gamma ray tomography, its simulation, and image reconstruction results. Image reconstruction was performed on the virtual experimental data from a Monte Carlo simulation. Image reconstruction algorithms that are known to be useful for limited angle data were applied and their results compared

  2. Calculation of direct effects of {sup 60}Co gamma rays on the different DNA structural levels: A simulation study using the Geant4-DNA toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Tajik, Marjan; Rozatian, Amir S.H. [Department of Physics, University of Isfahan, Hezar Jarib Street, Isfahan 81746-73441 (Iran, Islamic Republic of); Semsarha, Farid, E-mail: Semsarha@ibb.ut.ac.ir [Institute of Biochemistry and Biophysics (IBB), University of Tehran, P.O. Box: 13145-1384, Tehran (Iran, Islamic Republic of)

    2015-03-01

    In this study, simple single strand breaks (SSB) and double strand breaks (DSB) due to direct effects of the secondary electron spectrum of {sup 60}Co gamma rays on different organizational levels of a volume model of the B-DNA conformation have been calculated using the Geant4-DNA toolkit. Result of this study for the direct DSB yield shows a good agreement with other theoretical and experimental results obtained by both photons and their secondary electrons; however, in the case of SSB a noticeable difference can be observed. Moreover, regarding the almost constant yields of the direct strand breaks in the different structural levels of the DNA, calculated in this work, and compared with some theoretical studies, it can be deduced that the direct strand breaks yields depend mainly on the primary double helix structure of the DNA and the higher-order structures cannot have a noticeable effect on the direct DNA damage inductions by {sup 60}Co gamma rays. In contrast, a direct dependency between the direct SSB and DSB yields and the volume of the DNA structure has been found. Also, a further study on the histone proteins showed that they can play an important role in the trapping of low energy electrons without any significant effect on the direct DNA strand breaks inductions, at least in the range of energies used in the current study.

  3. Combined in-beam gamma-ray and conversion electron spectroscopy with radioactive ion beams

    Directory of Open Access Journals (Sweden)

    Konki J.

    2013-12-01

    Full Text Available In-beam gamma-ray and electron spectroscopy have been widely used as tools to study the broad variety of phenomena in nuclear structure. The SPEDE spectrometer is a new device to be used in conjunction with the MINIBALL germanium detector array to enable the detection of internal conversion electrons in coincidence with gamma rays from de-exciting nuclei in radioactive ion beam experiments at the upcoming HIE-ISOLDE facility at CERN, Switzerland. Geant4 simulations were carried out in order to optimise the design and segmentation of the silicon detector to achieve good energy resolution and performance.

  4. Research about combination of Gamma Knife and cobalt-60 radiation therapy to treat hypophysoma

    International Nuclear Information System (INIS)

    Xing Yueming; Zhao Xinping; Song Xiang; Wu Wei; Huang Bai

    2003-01-01

    Objective: To probe the therapeutic effectiveness of combination of Gamma Knife and cobalt-60 radiotherapy. Methods: 80 Hypophysoma patients who have been randomly grouped into two groups. Combination of Gamma Knife and cobalt-60 radiotherapy group and single Gamma knife group. Results: The therapeutic effectiveness of combination of Gamma Knife and cobalt-60 radiation therapy group was higher than that of single Gamma Knife group. Conclusion: The hospital that treat Hypophysoma with single Gamma Knife should add cobalt-60 radiotherapy in order to increase the local Hypophysoma dose

  5. Characterization of a power bipolar transistor as high-dose dosimeter for 1.9-2.2 MeV electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Fuochi, P.G., E-mail: fuochi@isof.cnr.i [ISOF-CNR Institute, Via P. Gobetti 101, I-40129, Bologna (Italy); Lavalle, M.; Corda, U. [ISOF-CNR Institute, Via P. Gobetti 101, I-40129, Bologna (Italy); Kuntz, F.; Plumeri, S. [Aerial, Parc d' Innovation Rue Laurent Fries F-67400 Illkirch (France); Gombia, E. [IMEM-CNR Institute, Viale delle Scienze 37 A, Loc. Fontanini, 43010 Parma (Italy)

    2010-04-15

    Results of the characterization studies on a power bipolar transistor investigated as a possible radiation dosimeter under laboratory condition using electron beams of energies from 2.2 to 8.6 MeV and gamma rays from a {sup 60}Co source and tested in industrial irradiation plants having high-activity {sup 60}Co gamma-source and high-energy, high-power electron beam have previously been reported. The present paper describes recent studies performed on this type of bipolar transistor irradiated with 1.9 and 2.2 MeV electron beams in the dose range 5-50 kGy. Dose response, post-irradiation heat treatment and stability, effects of temperature during irradiation in the range from -104 to +22 deg. C, dependence on temperature during reading in the range 20-50 deg. C, and the difference in response of the transistors irradiated from the plastic side and the copper side are reported. DLTS measurements performed on the irradiated devices to identify the recombination centres introduced by radiation and their dependence on dose and energy of the electron beam are also reported.

  6. Gamma-ray lasing by free nuclei and by matter-antimatter beams

    International Nuclear Information System (INIS)

    Rivlin, L.A.

    1997-01-01

    I discuss the possibilities to induce the gamma-ray emission departing from attempts to use the Moessbauer effect. Three separate approaches are considered: (A) Stimulated radiative transitions in deeply cooled nuclear beams with hidden inversion; (B) external two-photon ignition of nuclear lasing accompanied by gamma-ray giant pulse emission; and (C) burst-like radiative annihilation of relativistic beams of electrons and positrons or parapositronium atoms ignited by an external beam of soft photons

  7. Aspects of the immune response against proteic antigens submitted to the effects of 60Co gamma radiation

    International Nuclear Information System (INIS)

    Alves, Janaina Baptista.

    2004-01-01

    Considering the effects of gamma radiation on proteins and the capacity of the immune system to recognize modified macromolecules, we decided to evaluate some immunological aspects of B10.PL mice exposed to native or irradiated ovalbumin and bothrops toxin-1 (BthTx-1). In order to evaluate possible structural modifications of the molecules after being irradiated ( 60 Co gamma rays), bothrops toxin-1 was analysed by electrophoresis, while ovalbumin was submitted to analytical size exclusion chromatography. The toxin was also analysed by ESI-mass spectrometry. Our results indicate that radiation promoted modifications on both the molecules. Aiming to compare the toxicity of the native and irradiated forms of the toxin, an in vitro cytotoxicity assay, using CHO cells, was performed. According to our results, the modified toxin was 5 folds less toxic than its native counterpart. Sera of animals immunized with the native and irradiated proteins were analyzed in order to evaluate levels of IgG, as well as to quantify specific isotopes. While the native proteins induced a predominant Th2 response, the irradiated molecules apparently promoted a switch towards a Th1 pattern. We also performed a cell proliferation assay with splenocytes from mice immunized with either the native or the irradiated proteins, cultured in the presence of the antigens. Our results indicate that both the forms of the proteins induced a similar proliferative response. These data indicate a potential use of detoxified proteins as antigens for immunization. (author)

  8. Comparison of treatment in soybean grains between 60Co and e-beans applications

    International Nuclear Information System (INIS)

    Fanaro, Gustavo B.; Araujo, Michel M.; Thomaz, Fernanda S.; Duarte, Renato C.; Villavicencio, Anna Lucia C.H.

    2007-01-01

    Soybean is the most important oleaginous cultivated in Brazil, who is the second largest exported in the world, and generates high incomes, direct and indirectly, its oils could be used since to cook even to machine's fuel and the nutrients become basic for the feeding human being, beyond its by-products, that offer great diversities of products for the nourishing industry. Between the main factors that limit the attainment of high incomes, are the illnesses caused by microorganism like fungi, bacteria, and viruses that, in general, are difficult to control and cause damages on harvest of billions of dollar every year. An alternative to minimize the losses is preserving the grains through the irradiation that can come today from two different main sources: e-beam and 60 Co. Beyond power to be off when it will not be in use, the source of e-beams machines does not need to be recharged, is easily available, possess high tax of dose and low energy. However the 60 Co have low dose rate, high energy and the photons emission is continuous. This work aims to compare the effects of the radiation through viscosimetry, DNA Comet Assay and Cooking time techniques in soybean grains at doses 0, 1.0, 3.0 and 5.0kGy irradiated in ambient temperature at 60 Co source Gammacell 220 (A.E.C. Ltda) and in e-beam accelerator - Radiation Dynamics (Radiation Dynamics Co. model JOB, New York, USA), 1.5 MeV- 25mA with the lower dose. (author)

  9. Metabolism of 60Co in mollusca

    International Nuclear Information System (INIS)

    Nakahara, Motokazu

    1983-01-01

    After mollusca were bred in 60 Co-labeled sea water or were given 60 Co-labeled feed for certain hours, their tissues including the liver were removed as experimental samples. 60 Co metabolism was observed by the Sephadex gel filtration profile. A gel chromatogram of the liver in gastropoda showed a marked peak of 60 Co on the high-molecular side. Although the peak was observed on both high- and low-molecular sides in pelecypoda, it was more marked on the high-molecular side than on the low-molecular side. In cephalopoda, the peak pattern was similar to that in the other mollusca, but the proportion of low-molecular components was comparatively large. The gel filtration profile of 60 Co in various tissues of cephalopoda revealed the incorporation of 60 Co into the high-molecular components in blood, three peaks in the kidneys, and the incorporation of 60 Co into the low-molecular components in the branchial heart. The metabolism of 60 Co was dependent upon the chemical form of Co in gastropoda, and organic 60 Co was specifically observed in the high-molecular components. (Namekawa, K.)

  10. A comparison of mutagenic effects of common wheat by electron beam, fast neutron and 60Co gamma ray irradiation

    International Nuclear Information System (INIS)

    An Daochang; Wang Linqing

    1988-02-01

    After winter wheat was irradiated by electron beam, fast neutron and γ-rays, respectively, the RBE value of electron beam to both fast neutrons and γ-rays was less than one, the RBE value of fast neutron to γ-rays was largely more than one. This results indicated that biological effect of M 1 generation induced by electron beam was less than that of fast neutrons very much, and similar to γ-ray irradiation. With electron beam irradiation, the half-lethal doses of M 1 generation were from 185 to 370 Gy, closer to 370 Gy, the lethal doses from 740 to 925 Gy. M 2 mutation efficiency with electron beam treatment was larger as compared with that with both fast neutrons and γ-rays. A wider mutation spectrum and higher mutation efficiency compared with other physical mutagens can be obtained with electron beam irradiation, about 30% higher than that with γ-ray irradiation. The best doses of irradiation with electron beam were 370 to 555 Gy. Fast neutrons, a better dose of which was 25 Gy, could induce more mutants than that with γ-rays in M 2 generation. The dose in which biological injury reached to 50% was the best dose for M 2 mutants by electron beam irradiation

  11. Differential gene expression in primary fibroblasts induced by proton and cobalt-60 beam irradiation

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Bassler, Niels; Grzanka, Leszek

    2017-01-01

    profile: entrance, mid-SOBP and at the SOBP distal edge. Dose was delivered in three fractions × 3.5 Gy(RBE) (RBE 1.1). Cobalt-60 (Co-60) irradiation was used as reference. Real-time qPCR was performed to determine gene expression levels for 17 genes associated with inflammation response, fibrosis...... and angiogenesis. RESULTS: Differences in median gene expression levels were observed for multiple genes such as IL6, IL8 and CXCL12. Median IL6 expression was 30%, 24% and 47% lower in entrance, mid-SOBP and SOBP distal edge groups than in Co-60 irradiated cells. No genes were found to be oppositely regulated...... fibroblast cultures. Inflammatory factors were generally less extensively upregulated by proton irradiation compared with Co-60 photon irradiation. These effects may possibly influence the development of normal tissue damage in patients treated with proton beam therapy....

  12. Measurements of the light conversion efficiency of lithium borate for alpha particles relative to cobalt-60 gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bartlett, D.T.; Wall, B.F.; Fisher, E.S. (National Radiological Protection Board, Harwell (UK))

    1982-01-01

    The results are reported of measurements of the light conversion efficiencies of lithium borate TLD phosphor of British Nuclear Fuels Ltd. manufacture to 5.65 MeV and 2.4 MeV alpha particles relative to /sup 60/Co gamma radiation.

  13. Deep underground measurements of 60Co in steel exposed to the Hiroshima atomic bomb explosion.

    Science.gov (United States)

    Hult, Mikael; Gasparro, Joël; Vasselli, Roberto; Shizuma, Kiyoshi; Hoshi, Masaharu; Arnold, Dirk; Neumaier, Stefan

    2004-01-01

    When using gamma-ray spectrometry performed deep underground, it is possible to measure 60Co activities down to 0.1 mBq in steel samples of some 100 g without any pre-concentration. It is thus still possible to measure 60Co induced by neutrons from the atomic bomb explosion in Hiroshima in pieces of steel collected at distances up to about 1200 m slant range. The results of non-destructive measurements of eight steel samples are compared with the 1986 Dose Re-Evaluation (DS86) model calculations.

  14. Deep underground measurements of 60Co in steel exposed to the Hiroshima atomic bomb explosion

    International Nuclear Information System (INIS)

    Hult, Mikael; Gasparro, J.Joeel; Vasselli, Roberto; Shizuma, Kiyoshi; Hoshi, Masaharu; Arnold, Dirk; Neumaier, Stefan

    2004-01-01

    When using gamma-ray spectrometry performed deep underground, it is possible to measure 60 Co activities down to 0.1 mBq in steel samples of some 100 g without any pre-concentration. It is thus still possible to measure 60 Co induced by neutrons from the atomic bomb explosion in Hiroshima in pieces of steel collected at distances up to about 1200 m slant range. The results of non-destructive measurements of eight steel samples are compared with the 1986 Dose Re-Evaluation (DS86) model calculations

  15. Experimental determination of the beam quality dependence factors, kQ, for ionization chambers used in photon and electron dosimetry

    International Nuclear Information System (INIS)

    Guerra, A.S.; Laitano, R.F.; Pimpinella, M.

    1995-01-01

    Dosimetry in radiotherapy with ionization chambers calibrated in 60 Co gamma beams in terms of absorbed dose to water, D W , can be performed if a factor conventionally denoted as k Q is known. The factor k Q depends on the beam quality and the chamber characteristics. Calculated values of the k Q factors for many types of ionization chamber have been recently published. In this work the experimental determination of the k Q factors for various ionization chambers was performed for 6 MV and 15 MV photon beams and for a 14 MeV electron beam. The k Q factors were determined by a procedure based on relative measurements performed with the ionization chamber and ferrous sulphate solution in 60 Co gamma radiation and accelerator beams, respectively. The experimental k Q values are compared with the calculated values so far published. Theoretical and experimental k Q values are in fairly good agreement. The uncertainty in the experimental k Q factors determined in this work is less than about 1%, that is, appreciably smaller than the uncertainty of about 1.5% reported for the calculated values. (Author)

  16. The characteristics of epoxy resin cured by {gamma}-ray and E-beam

    Energy Technology Data Exchange (ETDEWEB)

    Nho, Y.C. E-mail: ycnho@kaeri.re.kr; Kang, Phil Hyun; Park, Jong Seok

    2004-10-01

    Epoxy resins are widely used as high-performance thermosetting resins for many industrial applications. In this study, the effect of an electron beam (E-beam) and {gamma}-ray irradiation on the curing of epoxy resins was investigated. Diglycidyl ether of bisphenol-A(DGEBA), diglycidyl ether of bisphenol-F(DGEBF) as epoxy resins, triarylsulfonium hexafluoroantimonate(TASHFA), and triarylsulfonium hexafluorophosphate(TASHFP) as initiators were used in this study. The chemical and mechanical characteristics of irradiated epoxy resins were compared after curing of E-beam and {gamma}-ray irradiation up to 50 kGy in N{sub 2} and air atmosphere. We ascertained the effect of oxygen on the radiation curing of epoxy resin. The thermal properties of cured epoxy were investigated using DMA and TGA. Mechanical properties such as flexural strength were measured. The chemical structures of cured epoxy were characterized by FT-NIR. The gel fraction and the stress at yield of epoxy resins irradiated by E-beam and {gamma}-ray in N{sub 2} atmosphere were also compared with those of epoxy resins irradiated by E-beam and {gamma}-ray in air.

  17. MoonBEAM: Gamma-Ray Burst Detectors on SmallSAT

    Science.gov (United States)

    Hui, C. M.; Briggs, M. S.; Goldstein, A. M.; Jenke, P. A.; Kocevski, D.; Wilson-Hodge, C. A.

    2018-01-01

    Moon Burst Energetics All-sky Monitor (MoonBEAM) is a CubeSat concept of deploying gamma-ray detectors in cislunar space to improve localization precision for gamma-ray bursts by utilizing the light travel time difference between a spacecraft in Earth and cislunar orbit. MoonBEAM is designed with high TRL components to be flight ready. This instrument would probe the extreme processes in cosmic collision of compact objects and facilitate multi-messenger time-domain astronomy to explore the end of stellar life cycles and black hole formations.

  18. Study of irradiated bothropstoxin-1 with 60Co gamma rays: immune system behavior

    International Nuclear Information System (INIS)

    Caproni, P.; Baptista, J.A.; Almeida, T.L. de; Nascimento, N.; Passos, L.A.C.

    2009-01-01

    Ionizing radiation has been successfully employed to modify the immunological properties of biomolecules. Very promising results were obtained when crude animal venoms, as well as isolated toxins, were treated with 60Co gamma rays, yielding toxoids with good immunogenicity. The achievement of modified antigens with lower toxicity and preserved or improved immunogenicity can be very useful. Ionizing radiation has already been proven to be a powerful tool to attenuate snake venom toxicity without affecting, and even increasing, their immunogenic properties. However, little is known about the modifications that irradiated molecules undergo and even less about the immunological response that such antigens elicit. In the present work, we investigated the immunological behavior of bothropstoxin-1, a K49 phospholipase, before and after irradiation. Structural modifications of the toxin were analyzed by SDS-PAGE. Isogenic mice were immunized with either the native or the irradiated toxin. The circulating antibodies were isotyped and titrated by ELISA. According to our data, irradiation promoted structural modifications in the toxin characterized by higher molecular weight forms of proteins (aggregates and oligomers). The results also indicated that irradiated toxins were immunogenic and antibodies elicited by them were able to recognize the native toxin in ELISA. These findings suggest that irradiation of toxic proteins can promote significant modifications in their structures; however they still retain many of the original antigenic and immunological properties of native proteins. Also, our data indicate that irradiated proteins induce higher titers of IgG2a and IgG2b, suggesting that Th1 cells are predominantly involved in the immune response. (author)

  19. Meiosis and ISSR analysis on genetic variation of {sup 60}Co {gamma}-rays irradiated variants of cut chrysanthemum

    Energy Technology Data Exchange (ETDEWEB)

    Lili, Xing; Fadi, Chen; Hengbin, Miao [College of Horticulture, Nanjing Agricultural University, Nanjing, Jiangsu (China)

    2009-08-15

    Cytology and ISSR technology were used to analyze genetic variations of {sup 60}Co {gamma}-rays induced variants of cut chrysanthemum 'Changzi', for further exploring the mechanism of irradiation and providing theoretical basis for breeding of chrysanthemum. The results showed that, meiotic abnormality ratio of lagging chromosome and chromosome bridge in variants were significantly higher than those in the control at anaphase I and II. The abnormality ratio was also raised with irradiation doses increasing. The highest ratio of two abnormal phenomena at anaphase I was 9.0%, 11.3%, and at anaphase II 15.5%, 8.6%, respectively. Polymorphic bands of 112 were amplified by 21 ISSR primers and the polymorphism rate was 71.3%, which proved that DNA changed in different degrees. These variants were divided into 5 groups by UPGMA based on Jaccard coefficient. It was observed that the clustering result related to their characters of flower shape and color variations. (authors)

  20. Calibration of intense 60Co gamma ray sources at the Savannah River Plant

    International Nuclear Information System (INIS)

    Bibler, N.E.

    1976-05-01

    Three different dosimeters were used to calibrate Savannah River Plant 60 Co sources having intensities greater than 10 7 rads/hr. These dosimeters are (a) ceric sulfate dissolved in 0.4M H 2 SO 4 , (b) oxalic acid dissolved in water, and (c) a commercially available nylon film containing a radiochromic dye. Response per unit dose to these dosimeters is independent of radiation intensity at 10 4 to 10 11 rads/hr. The dosimeters were calibrated at 6.0 x 10 5 rads/hr with a 60 Co source whose intensity was determined with the standard Fricke dosimeter. For the sources at 10 7 rads/hr or greater, intensities were calculated from slopes of linear plots of dosimeter response versus irradiation time. Individual dose rates varied from 1.0 x 10 7 to 4.6 x 10 7 rads/hr. Each source was calibrated with at least two different dosimeters. Relative standard deviations varied from 2 to 9 percent. A conservative estimate of the uncertainty in the accuracy of these dosimeters is 10 percent. Of the three dosimeters, the nylon film is easiest to use and is therefore recommended for future calibrations

  1. Comparative effects of gamma-rays and electron beams on peroxide formation in phosphatidylcholine

    International Nuclear Information System (INIS)

    Todoriki, S.; Hayashi, T.

    1994-01-01

    Phosphatidylcholine was irradiated in the state of a film or liposome with gamma-rays or electron beams, and the amount of peroxide was determined to compare the effects of the two types of radiation. The amounts of peroxide formed in both the film and liposome with gamma-rays were significantly larger than those with electron beams, when the samples were irradiated at the same dose. Proteins such as bacteriorhodopsin reduced the degree of peroxide formation in liposome, and the effect of gamma-rays was much larger than that of electron beams, even in the presence of protein. The results of the present investigation indicate that the effects of gamma-rays on peroxide formation in phosphatidylcholine were significantly larger than those of electron beams, irrespective of the state of the lipid

  2. The effect of {sup 60}Co ({gamma}-ray) irradiation on the electrical characteristics of Au/SnO{sub 2}/n-Si (MIS) structures

    Energy Technology Data Exchange (ETDEWEB)

    Goekcen, M. [Physics Department, Faculty of Arts and Sciences, Gazi University, 06500 Teknikokullar, Ankara (Turkey); Tataroglu, A. [Physics Department, Faculty of Arts and Sciences, Gazi University, 06500 Teknikokullar, Ankara (Turkey)], E-mail: ademt@gazi.edu.tr; Altindal, S.; Buelbuel, M.M. [Physics Department, Faculty of Arts and Sciences, Gazi University, 06500 Teknikokullar, Ankara (Turkey)

    2008-01-15

    The effect of {sup 60}Co ({gamma}-ray) irradiation on the electrical properties of Au/SnO{sub 2}/n-Si (MIS) structures has been investigated using the capacitance-voltage (C-V) and conductance-voltage (G/{omega}-V) measurements in the frequency range 1 kHz to 1 MHz at room temperature. The MIS structures were exposed to {gamma}-rays at a dose rate of 2.12 kGy/h in water and the range of total dose was 0-500 kGy. It was found that the C-V and G/{omega}-V curves were strongly influenced with both frequency and the presence of the dominant radiation-induced defects, and the series resistance was increased with increasing dose. Also, the radiation-induced threshold voltage shift ({delta}V{sub T}) strongly depended on radiation dose and frequency, and the density of interface states N{sub ss} by Hill-Coleman method decreases with increasing radiation dose.

  3. Effect of 60Co-gamma radiation on the properties of furs

    International Nuclear Information System (INIS)

    Raina, R.K.; Wali, B.K.; Wani, A.M.

    1990-01-01

    Furs pretanned with various combinations of vegetable tanning agents and retanned with alum have been irradiated with 60 Co γ-radiation in the dose range 5.0-114.0 kGy. The physico-chemical modifications induced by the radiation have been assessed by measuring changes in tensile strength, absorption of water, elongation and shrinkage temperature. For investigations, samples have been taken from the same topographic region of the rabbit furs, belonging to the same age and sex. The results are discussed. (author)

  4. Effect of 60Co-gamma radiation on the properties of furs

    Science.gov (United States)

    Raina, R. K.; Wali, B. K.; Wani, A. M.

    Furs pretanned with various combinations of vegetable tanning agents and retanned with alum have been irradiated with 60Co γ-radiation in the dose range 5.0-114.0 kGy. The physico-chemical modifications induced by the radiation have been assessed by measuring changes in tensile strength, absorption of water, elongation and shrinkage temperature. For investigations, samples have been taken from the same topographic region of the rabbit furs, belonging to the same age and sex. The results are discussed hereunder.

  5. Ablation of polytetrafluoroethylene using a continuous CO2 laser beam

    International Nuclear Information System (INIS)

    Tolstopyatov, E M

    2005-01-01

    The ablation of polytetrafluoroethylene (PTFE) is studied using a continuous CO 2 laser beam of 30-50 W at a mean intensity of 0.05-50 MW m -2 . The ablation products and changes in the target layer are examined using infrared spectroscopy, x-ray photoelectron spectroscopy, x-ray diffraction and electron microscopy. The main experiments were conducted with an unfocused beam of intensity 0.9-1.2 MW m -2 . The radiation-polymer interaction characteristics were found to change appreciably as the ablation conditions are approached. Within the polymer layer, light scattering diminishes and true resonant light absorption increases. Two distinct polymer components, which differ primarily in their resistance to CO 2 laser radiation, were found to exist under ablation conditions. The less stable component depolymerizes intensively, while the more resistant component is blown up into fibres by intense gas flow. The reasons behind this behaviour are discussed. Preliminary gamma irradiation of PTFE is found to have a significant influence on the laser ablation process

  6. Report on EUROMET.RI(I)-K1 and EUROMET.RI(I)-K4 (EUROMET project no. 813): Comparison of air kerma and absorbed dose to water measurements of {sup 60}Co radiation beams for radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Csete, I. [National Office of Measures (OMH) - pilot laboratory and corresponding author (Hungary); Leiton, A.G. [Research Centre for Energy, Environment and Technology (CMRI-CIEMAT) (Spain); Sochor, V. [Czech Metrology Institute (CMI) (Czech Republic); Lapenas, A. [Latvian National Metrology Center (LNMC-RMTC) (Latvia); Grindborg, J.E. [Swedish Radiation Protection Authority (SSI) (Sweden); Jokelainen, I. [Radiation and Nuclear Safety Authority (STUK) (Finland); Bjerke, H. [Norwegian Radiation Protection Authority (NRPA) (Norway); Dobrovodsky, J. [Slovak Institute of Metrology (SMU) (Slovakia); Megzifene, A. [International Atomic Energy Agency, IAEA, Vienna (Austria); Hourdakis, C.J. [Hellenic Atomic Energy Committee (HAEC-HIRCL) (Greece); Ivanov, R. [National Centre of Metrology (NCM) (Bulgaria); Vekic, B. [Rudjer Boskovic Institute (IRB) (Croatia); Kokocinski, J. [Central Office of Measures (GUM) (Poland); Cardoso, J. [Institute for Nuclear Technology (ITN-LMRIR) (Portugal); Buermann, L. [Physikalisch Technische Bundesanstalt (PTB) (Germany); Tiefenboeck, W. [Bundesamt fur Eich und Vermesungswesen (BEV) (Austria); Stucki, G. [17 Bundesamt fur Metrologie (METAS) (Switzerland); Van Dijk, E. [NMi Van Swinden Laboratorium (NMi) (Netherlands); Toni, M.P. [ENEA-CR Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti (ENEA) (Italy); Minniti, R. [20 National Institute of Standards and Technology (NIST) (United States); McCaffrey, J.P. [National Research Council Canada (NRC) (Canada); Silva, C.N.M. [National Metrology Laboratory of Ionizing Radiation (LNMRI-IRD) (Brazil); Kharitonov, I. [D I Mendeleyev Institute for Metrology (VNIIM) (RU); Webb, D. [Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) (Australia); Saravi, M. [National Atomic Energy Commission (CNEA-CAE) (Argentina); Delaunay, F. [Laboratoire National Henri Becquerel (LNE-LNHB) (France)

    2010-06-15

    The results of an unprecedented international effort involving 26 countries are reported. The EUROMET.RI(I)-K1 and EUROMET.RI(I)-K4 key comparisons were conducted with the goal of supporting the relevant calibration and measurement capabilities (CMC) planned for publication by the participant laboratories. The measured quantities were the air kerma (K{sub air}) and the absorbed dose to water (Dw) in {sup 60}Co radiotherapy beams. The comparison was conducted by the pilot laboratory MKEH (Hungary), in a star-shaped arrangement from January 2005 to December 2008. The calibration coefficients of four transfer ionization chambers were measured using two electrometers. The largest deviation between any two calibration coefficients for the four chambers in terms of air kerma and absorbed dose to water was 2.7% and 3.3% respectively. An analysis of the participant uncertainty budgets enabled the calculation of degrees of equivalence (DoE), in terms of the deviations of the results and their associated uncertainties. As a result of this EUROMET project 813 comparison, the BIPM key comparison database (KCDB) will include eleven new Kair and fourteen new D{sub w} DoE values of European secondary standard dosimetry laboratories (SSDLs), and the KCDB will be updated with the new DoE values of the other participant laboratories. The pair-wise degrees of equivalence of participants were also calculated. In addition to assessing calibration techniques and uncertainty calculations of the participants, these comparisons enabled the experimental determinations of N{sub Dw}/N{sub Kair} ratios in the {sup 60}Co gamma radiation beam for the four radiotherapy transfer chambers. (authors)

  7. Borosilicate glass for gamma irradiation fields

    Science.gov (United States)

    Baydogan, N.; Tugrul, A. B.

    2012-11-01

    Four different types of silicate glass specimens were irradiated with gamma radiation using a Co-60 radioisotope. Glass specimens, with four different chemical compositions, were exposed to neutron and mixed neutron/gamma doses in the central thimble and tangential beam tube of the nuclear research reactor. Optical variations were determined in accordance with standardisation concept. Changes in the direct solar absorbance (αe) of borosilicate glass were examined using the increase in gamma absorbed dose, and results were compared with the changes in the direct solar absorbance of the three different type silicate glass specimens. Solar absorption decreased due to decrease of penetration with absorbed dose. αe of borosilicate increased considerably when compared with other glass types. Changes in optical density were evaluated as an approach to create dose estimation. Mixed/thermal neutron irradiation on glass caused to increse αe.

  8. Description of morphologic characters in avocado trees (Persea americana. Mill) var. Hass, submitted to gamma radiation of 60 Co

    International Nuclear Information System (INIS)

    Sandoval R, L.

    2004-01-01

    It was carried out the characterization of 77 trees of avocado ''Hass'' subjected to gamma radiation of Co 60 , in doses of 0, 5, 10,15, 20 and 25 Gy based on previous studies of radiosensitivity with ends of improvement located in the experimental center ''La Labor'' belonging to the foundation Salvador Sanchez Colin. CICTAMEX. S C. in Temascaltepec, Mexico. It was carried out the morphological characterization of this variety according to the nomenclature settled down by the International Office of Genetic Resources (IBPGRI), registering 27 variables for the description of the tree, 33 for description of the fruit and 14 for the characterization of the seed. Regarding the architectural characterization 10 variables were evaluated. Using gamma radiation of Co 60 in the doses of 15 and 20 Gy it was detected a reduction of 22% in the portage of the tree, likewise had reduction the diameter of the trunk and of the foliage. It was found that the reduction in the behavior of the tree induces to a bigger variation of the form of the same one, in the distribution of the branches in the form of the fruit and in the form of the seed you Also detects a remarkable increment in the productivity of some hoist irradiated regarding the architecture of the tree one observes that the angle of inclination of the branches increase when being increased the radiation dose and that the longitude of the annual section of growth decreased significantly in the doses of 20 and 25 Gy. One observes a significant Increment in the I number of buds prolepticos in those hoist irradiated in the I finish mbdulo of rhythmic growth. Io that indicates a change substantial in the I inhabit of growth With the purpose of determining if the changes in morphology and architecture of the tree corresponded with the modification at level meristematico, they were carried out observations to the court microscope of having knitted apical vegetative meristematico in samples of you hoist of all the treatments

  9. The measurement of phi 60 mm x 600 mu m silicon PIN detector gamma sensitivity and time respond

    CERN Document Server

    Hu Meng Chun; Ye Wen Ying

    2002-01-01

    phi 60 mm x 600 mu m silicon PIN detector is a large area and high sensitive one which has been developed in near years. The authors have measured their gamma sensitivity and the time response. The experiment and theoretical calculated results in: sup 6 sup 0 Co gamma sensitivity is about 5 fC centre dot cm sup 2 /MeV, the rise time is about 10 ns and the half-high-width time is about 35 ns

  10. Investigations on Pasteurization of Cold Marinades by {sup 60}Co Gamma Rays; Recherches sur la Pasteurisation a Froid De Marinades par les Rayons Gamma du {sup 60}Co; Issledovaniya pasterizatsii kholodnykh marinadov gamma-luchami; Investigaciones Sobre la Pasteurizacion de Escabeches Frios por Irradiacion Gamma con {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Schoenborn, W.; Kinkel, R J.; Hafferl, W. [Battelle Institut e.V., Frankfurt/Main, Federal Republic of Germany (Germany)

    1966-11-15

    Marinated herring fillets are a fish product matured under the action of acetic acid and salt and marketed in a spiced brine containing about 3% salt and acetic acid (pH 4). Since the usual addition of the preservative hexamethylene-tetramine has been restricted to a limited period of time by the new German food law, investigations were made on pasteurization by means of ionizing rays, as a new method of preservation without the addition of other preservatives. Decay of this food product was caused by heterofermentative lactic-acid bacteria, which decarboxy- lated the amino acids set free from the protein; the decay was a result of carbon dioxide bombardment. The marinades were packed into flat tins holding about 125 g, and exposed to {sup 60}Co gamma rays from an under-water source, while being cooled. The shelf life of the tinned marinades was extended by the irradiation. The period up to bombardment at 15 Degree-Sign C was three times as long as usual in cases of irradiation with 155 krad. The critical number of 1 million germs per ml at 15 Degree-Sign C was also reached after a period three times as long as usual upon irradiation with 160 krad. The LD{sub 99} of three isolated strains of lactic-acid bacteria irradiated in a salt-peptone solution was 113, 165 and 144 krad, respectively. Since at 15 Degree-Sign C the growth of the germs is retarded, while at 20 Degree-Sign C it is practically unrestrained, the period of durability at a storage temperature of 18 Degree-Sign C could only be doubled by irradiation with 280 krad. The organoleptic tests were based on preference analyses by means of the nine-step Hedonic scale, and on difference tests (triangle test) and were performed by a paneli At 70 krad the taste is still acceptable at 140 krad there is a distinct taste of rays and at 280 krad the taste is disagreeable. A distinct improvement in taste is achieved by irradiation at low temperatures (-30 Degree-Sign C) and by the addition of ascorbic acid, sorbitol

  11. Development of irradiator 60Co sources

    International Nuclear Information System (INIS)

    Mosca, Rodrigo C.; Moura, Eduardo S.; Zeituni, Carlos A.; Mathor, Monica B.

    2011-01-01

    According to a recent report by the International Agency for Research on Cancer (IARC) / WHO (2008-2010), the global impact of cancer more than doubled in 30 years. In this report, it was estimated that occurred about 12 million new cancer cases and 7 million deaths. In Brazil in 2010, with estimates for the year 2011, point to the occurrence of 489,270 new cases of cancer. Among the possibilities for cancer treatment, radiotherapy is one of the most important therapeutic and resources used to combat it. However, inherent complications of treatment can occur such as tiredness, loss of appetite, radiodermatitis and in more extreme cases late radionecrosis. In order to reproduce a point of radionecrosis in the vicinity of radiodermatitis to mimic these effects in animals, producing a model for assessment of tissue repair, we propose the setting up of an irradiator source of collimated 60 Co. The development of was based on 11 sources of 60 Co with 1 mm thickness that were inserted by inference in stainless steel 'gate-source' screw (patent pending) and later adjusted in a cross-shaped arrangement reinforced so that the beam radiation is directed to a target point, saving for other regions around this target point. The main use of this irradiator with sources of 60 Co is just one cause radionecrosis point (target point) of approximately 5 mm 2 with a surrounding and adjacent area of radiodermatitis around about 8 to 10 mm 2 in laboratory animals for subsequent coating with epidermal-dermal matrix populated by a cell culture of human fibroblasts, keratinocytes and mesenchymal stem cells. With that said, its use will be valuable for evaluation of curative treatments against the bone and radionecrosis or palliative treatment rather than as it is currently assumed. (author)

  12. Effect of Gamma and Electron Beam Irradiation on Textile Waste Water

    International Nuclear Information System (INIS)

    Selambakkannu, S.; Khomsaton Abu Bakar; Ting, T.M.

    2011-01-01

    In this studies gamma and electron beam irradiation was used to treat textile waste water. Comparisons between both types of irradiation in terms of effectiveness to degrade the pollutants present in textile waste water was done. Prior to irradiation, the raw wastewater was diluted using distilled water to a target concentration of COD 400 mg/l. The sample was irradiated at selected doses between the ranges of 10 kGy to 100 kGy. The results showed that irradiation has significantly contributed in the reduction of the highly colored refractory organic pollutants. The COD removal at the lowest dose, 10 kGy, was reduced to 390 mg/l for gamma and 400 mg/l for electron beam. Meanwhile, at the highest dose, 100 kGy, the COD was reduced to 125 mg/l for gamma and 144 mg/l for electron beam. The degree of removal is influenced by the dose introduced during the treatment process. As the dose increased, the higher the removal of organic pollutant was recorded. However, gamma irradiation is more effective although the differences are not significant between gamma and electron beam irradiation. On the other hand, other properties of the wastewater such as pH, turbidity, suspended solid, BOD and color also shows a gradual decrease as the dose increases for both types of irradiation. (author)

  13. Supplementary comparison CCRI(I)-S2 of standards for absorbed dose to water in 60Co gamma radiation at radiation processing dose levels

    DEFF Research Database (Denmark)

    Burns, D. T.; Allisy-Roberts, P. J.; Desrosiers, M. F.

    2011-01-01

    Eight national standards for absorbed dose to water in 60Co gamma radiation at the dose levels used in radiation processing have been compared over the range from 1 kGy to 30 kGy using the alanine dosimeters of the NIST and the NPL as the transfer dosimeters. The comparison was organized...... by the Bureau International des Poids et Mesures, who also participated at the lowest dose level using their radiotherapy-level standard for the same quantity. The national standards are in general agreement within the standard uncertainties, which are in the range from 1 to 2 parts in 102. Evidence of a dose...

  14. Relative biological effectiveness measurements using murine lethality and survival of intestinal and hematopoietic stem cells after Fermilab neutrons compared to JANUS reactor neutrons and 60Co gamma rays

    International Nuclear Information System (INIS)

    Hanson, W.R.; Crouse, D.A.; Fry, R.J.M.; Ainsworth, E.J.

    1984-01-01

    The relative biological effectiveness (RBE) of the 25-MeV (average energy) neutron beam at the Fermi National Accelerator Laboratory was measured using murine bone marrow (LD/sub 50/30/) and gut (LD/sub 50/6/) lethality and killing of hematopoietic colony forming units (CFU-S) or intestinal clonogenic cells (ICC). The LD/sub 50/30/ and LD/sub 50/6/ for mice exposed to the Fermilab neutron beam were 6.6 and 8.7 Gy, respectively, intermediate between those of JANUS neutrons and 60 Co γ rays. The D 0 values for CFU-S and ICC were 47 cGy and 1.05 Gy, respectively, also intermediate between the lowest values found for JANUS neutrons and the highest values found after 60 Co γ rays. The split-dose survival ratios for CFU-S at intervals of 1-6 hr between doses were essentially 1.0 for both neutron sources. The 3-hr split-dose survival ratios for ICC were 1.0 for JANUS neutrons, 1.85 for Fermilab neutrons, and 6.5 for 60 Co γ rays. The RBE estimates for LD/sub 50/30/ were 1.5 and 2.3 for Fermilab and JANUS neutrons, respectively. Based on LD/sub 50/6/, the RBEs were 1.9 (Fermilab) and 3.0 (JANUS). The RBEs for CFU-S D 0 were 1.4 (Fermilab) and 1.9 (JANUS) and for jejunal microcolony D 0 1.4 (Fermilab) and 2.8 (JANUS)

  15. Deep underground measurements of {sup 60}Co in steel exposed to the Hiroshima atomic bomb explosion

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Mikael E-mail: mikael.hult@cec.eu.int; Gasparro, J.Joeel; Vasselli, Roberto; Shizuma, Kiyoshi; Hoshi, Masaharu; Arnold, Dirk; Neumaier, Stefan

    2004-09-01

    When using gamma-ray spectrometry performed deep underground, it is possible to measure {sup 60}Co activities down to 0.1 mBq in steel samples of some 100 g without any pre-concentration. It is thus still possible to measure {sup 60}Co induced by neutrons from the atomic bomb explosion in Hiroshima in pieces of steel collected at distances up to about 1200 m slant range. The results of non-destructive measurements of eight steel samples are compared with the 1986 Dose Re-Evaluation (DS86) model calculations.

  16. National comparison of activity measurements of 131I, 60Co, and 133Ba in Indonesia

    International Nuclear Information System (INIS)

    Wurdiyanto, Gatot; Marsoem, Pujadi; Widodo, Susilo; Iskandar, Dadong; Muhayatun; Hartoyo, Unggul; Sugino; Gede Sutresna, I.; Hutabarat, Tommy; Suparman, Ibon; Purwanto, Setyo

    2014-01-01

    National comparisons of radioactivity measurements of 131 I and 60 Co (in 2010) and of 133 Ba (in 2011) were carried out within the framework of the National Radiation Metrology Laboratory Program of Indonesia, coordinated by PTKMR-BATAN. Eleven laboratories took part in the comparison, and all measurements were made using gamma spectrometry, on point sources with an activity between 2000 Bq and 6000 Bq. Several laboratories reported values which were more than 10% different from the reference value for 131 I and 133 Ba. Possible reasons for these differences are discussed. This program will be continued with other radionuclides to maintain and control quality assurance for the local laboratories. - Highlights: • PTKMR-BATAN coordinated national comparison of 131 I, 60 Co and 133 Ba. • Eleven laboratories took part in the comparison. • All measurements were done using gamma spectrometry methods. • For 131 I and 133 Ba, 3 laboratories have more than 10% difference from reference laboratory value

  17. Quality of tri-Co-60 MR-IGRT treatment plans in comparison with VMAT treatment plans for spine SABR.

    Science.gov (United States)

    Choi, Chang Heon; Park, So-Yeon; Kim, Jung-In; Kim, Jin Ho; Kim, Kyubo; Carlson, Joel; Park, Jong Min

    2017-02-01

    To investigate the plan quality of tri-Co-60 intensity-modulated radiation therapy (IMRT) plans for spine stereotactic ablative radiotherapy (SABR). A total of 20 patients with spine metastasis were retrospectively selected. For each patient, a tri-Co-60 IMRT plan and a volumetric-modulated arc therapy (VMAT) plan were generated. The spinal cords were defined based on MR images for the tri-Co-60 IMRT, while isotropic 1-mm margins were added to the spinal cords for the VMAT plans. The VMAT plans were generated with 10-MV flattening filter-free photon beams of TrueBeam STx ™ (Varian Medical Systems, Palo Alto, CA), while the tri-Co-60 IMRT plans were generated with the ViewRay ™ system (ViewRay inc., Cleveland, OH). The initial prescription dose was 18 Gy (1 fraction). If the tolerance dose of the spinal cord was not met, the prescription dose was reduced until the spinal cord tolerance dose was satisfied. The mean dose to the target volumes, conformity index and homogeneity index of the VMAT and tri-Co-60 IMRT were 17.8 ± 0.8 vs 13.7 ± 3.9 Gy, 0.85 ± 0.20 vs 1.58 ± 1.29 and 0.09 ± 0.04 vs 0.24 ± 0.19, respectively. The integral doses and beam-on times were 16,570 ± 1768 vs 22,087 ± 2.986 Gy cm 3 and 3.95 ± 1.13 vs 48.82 ± 10.44 min, respectively. The tri-Co-60 IMRT seems inappropriate for spine SABR compared with VMAT. Advances in knowledge: For spine SABR, the tri-Co-60 IMRT is inappropriate owing to the large penumbra, large leaf width and low dose rate of the ViewRay system.

  18. Gamma ray beam transmutation

    International Nuclear Information System (INIS)

    Imasaki, K.; Li, D.; Miyamoto, S.; Amano, S.; Motizuki, T.

    2007-01-01

    We have proposed a new approach to nuclear transmutation by a gamma ray beam of Compton scattered laser photon. We obtained 20 MeV gamma ray in this way to obtain transmutation rates with the giant resonance of 1 97Au and 1 29Iodine. The rate of the transmutation agreed with the theoretical calculation. Experiments on energy spectrum of positron, electron and neutron from targets were performed for the energy balance and design of the system scheme. The reaction rate was about 1.5∼4% for appropriate photon energies and neutron production rate was up to 4% in the measurements. We had stored laser photon more than 5000 times in a small cavity which implied for a significant improvement of system efficiency. Using these technologies, we have designed an actual transmutation system for 1 29Iodine which has a 16 million year's activity. In my presentation, I will address the properties of this scheme, experiments results and transmutation system for iodine transmutation

  19. SU-E-T-335: Dosimetric Investigation of An Advanced Rotating Gamma Ray System for Imaged Guided Radiation Therapy

    International Nuclear Information System (INIS)

    Ma, C; Eldib, A; Chibani, O; Li, J; Chen, L; Li, C; Mora, G

    2015-01-01

    Purpose: Co-60 beams have unique dosimetric properties for cranial treatments and thoracic cancers. The conventional concern about the high surface dose is overcome by modern system designs with rotational treatment techniques. This work investigates a novel rotational Gamma ray system for image-guided, external beam radiotherapy. Methods: The CybeRT system (Cyber Medical Corp., China) consists of a ring gantry with either one or two treatment heads containing a Gamma source and a multileaf collimator (MLC). The MLC has 60 paired leaves, and the maximum field size is either 40cmx40cm (40 pairs of 0.5cm central leaves, 20 pairs of 1cm outer leaves), or 22cmx40cm (32 pairs of 0.25cm central leaves, 28 pairs of 0.5cm outer leaves). The treatment head(s) can swing 35° superiorly and 8° inferiorly, allowing a total of 43° non-coplanar beam incident. The treatment couch provides 6-degrees-of-freedom motion compensation and the kV cone-beam CT system has a spatial resolution of 0.4mm. Monte Carlo simulations were used to compute dose distributions and compare with measurements. A retrospective study of 98 previously treated patients was performed to compare CybeRT with existing RT systems. Results: Monte Carlo results confirmed the CybeRT design parameters including output factors and 3D dose distributions. Its beam penumbra/dose gradient was similar to or better than that of 6MV photon beams and its isocenter accuracy is 0.3mm. Co-60 beams produce lower-energy secondary electrons that exhibit better dose properties in low-density lung tissues. Because of their rapid depth dose falloff, Co-60 beams are favorable for peripheral lung tumors with half-arc arrangements to spare the opposite lung and critical structures. Superior dose distributions were obtained for head and neck, breast, spine and lung tumors. Conclusion: Because of its accurate dose delivery and unique dosimetric properties of C-60 sources, CybeRT is ideally suited for advanced SBRT as well as

  20. SU-E-T-335: Dosimetric Investigation of An Advanced Rotating Gamma Ray System for Imaged Guided Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ma, C; Eldib, A; Chibani, O; Li, J; Chen, L [Fox Chase Cancer Center, Philadelphia, PA (United States); Li, C [Renmin Hospital of Wuhan University, Wuhan (China); Mora, G [Universidade de Lisboa, Codex, Lisboa (Portugal)

    2015-06-15

    Purpose: Co-60 beams have unique dosimetric properties for cranial treatments and thoracic cancers. The conventional concern about the high surface dose is overcome by modern system designs with rotational treatment techniques. This work investigates a novel rotational Gamma ray system for image-guided, external beam radiotherapy. Methods: The CybeRT system (Cyber Medical Corp., China) consists of a ring gantry with either one or two treatment heads containing a Gamma source and a multileaf collimator (MLC). The MLC has 60 paired leaves, and the maximum field size is either 40cmx40cm (40 pairs of 0.5cm central leaves, 20 pairs of 1cm outer leaves), or 22cmx40cm (32 pairs of 0.25cm central leaves, 28 pairs of 0.5cm outer leaves). The treatment head(s) can swing 35° superiorly and 8° inferiorly, allowing a total of 43° non-coplanar beam incident. The treatment couch provides 6-degrees-of-freedom motion compensation and the kV cone-beam CT system has a spatial resolution of 0.4mm. Monte Carlo simulations were used to compute dose distributions and compare with measurements. A retrospective study of 98 previously treated patients was performed to compare CybeRT with existing RT systems. Results: Monte Carlo results confirmed the CybeRT design parameters including output factors and 3D dose distributions. Its beam penumbra/dose gradient was similar to or better than that of 6MV photon beams and its isocenter accuracy is 0.3mm. Co-60 beams produce lower-energy secondary electrons that exhibit better dose properties in low-density lung tissues. Because of their rapid depth dose falloff, Co-60 beams are favorable for peripheral lung tumors with half-arc arrangements to spare the opposite lung and critical structures. Superior dose distributions were obtained for head and neck, breast, spine and lung tumors. Conclusion: Because of its accurate dose delivery and unique dosimetric properties of C-60 sources, CybeRT is ideally suited for advanced SBRT as well as

  1. Behavior of the sorption of 60 Co in aqueous solution on inorganic materials as function of p H

    International Nuclear Information System (INIS)

    Granados, F.; Bulbulian, S.; Solache R, M.; Bertin, V.

    2004-01-01

    The sorption of the 60 Co is evaluated in aqueous solution on Mg O, MnO 2 , TiO 2 , Sn O, activated carbon and hydrotalcite calcined as a function of the p H, using the method for lots and quantifying at the 60 Co for gamma spectrometry. Likewise it was explained the one behavior of the sorption of the 60 Co in the materials with base in the chemical species of this radioactive isotope in aqueous solution. The chemical species of the 60 Co in solution were identified by electrophoresis of high voltage for the different p H values. It was found that under the experimental conditions, the 60 Co showed a significant sorption on MnO 2 , TiO 2 and activated carbon. On the other hand, in Mg O, Sn O and calcined hydrotalcite also was observed a sorption, although in smaller quantities. The studied hydrated metallic oxides retained the 60 Co for ion exchange via. It was found that the 60 Co was present as a cationic specie to p H 1, 3, 5 and 7 and like a neutral specie to alkaline p H. (Author)

  2. Effects of gamma radiation in mechanical and optical properties of polycarbonate

    International Nuclear Information System (INIS)

    Araujo, E.S.; Khoury, H.J.; Silveira, S.V. da; Dallolio, A.

    1990-01-01

    The polycarbonates are used in different industrial applications due to their excellent dielectric proprieties, impact resistance and high temperature resistance. For some of this applications, the polycarbonates are exposed to gamma radiation which produces a molecular scission, occasioning changes in the polycarbonate proprieties. To estimate the radiation effects in the DUROLON polycarbonate, samples were irradiated with sup(60)Co gamma beam with doses between 0,2kGy and 50kGy. The results obtained shown variations in the yellowness index above 1kGy dose. Their mechanical proprieties are not changed in the above dose interval. (author)

  3. Comparison of electron beam and gamma irradiation for the sterilization of allograft

    International Nuclear Information System (INIS)

    Jong il Choi; Nak Yun Sung; Hee Sub Lee; Jae Hun Kim; Myung Woo Byun; Ju Woon Lee

    2008-01-01

    Full text: For human use, it is necessary to sterilize the allograft in order to reduce the risk of infections and associated complications. In this study, we compared the effects of electron beam and gamma irradiation for the sterilization of the demineralized bone matrix (DBM) in a carboxymethylcellulose (CMC) carrier with regard to the physiological and osteoinductive properties. The CMC carrier was irradiated at the various doses. and the viscosity of the irradiated CMC was measured. The viscosity of the CMC irradiated with electron beam was higher than that with gamma ray. Also, the addition of vitamin C as the radical scavenger and irradiation at -70 degree C were shown to be effective in preventing the degradation of CMC by the irradiation. To investigate the effect of irradiation on the osteoinduction of DBM, alkaline phosphatase (ALP) activity with C2C12 cells was measured. The ALP activity of DBM in CMC was higher when irradiated with the electron beam compared with the gamma ray. The bone morphogenetic proteins (BMP) were extracted from DBM irradiated with electron beam and gamma ray, and it was found that the extraction efficiency of BMP was higher from DBM irradiated with the electron beam. This was reasoned for the higher APL activity of the electron beam irradiated DBM. With the advantages of electron beam such as short processing time, in-line processing, and low equipment cost, these results suggest that electron beam irradiation is recommendable for the sterilization of DBM allograft. (Author)

  4. Behavior of the sorption of {sup 60} Co in aqueous solution on inorganic materials as function of p H; Comportamiento de la sorcion del {sup 60} Co en solucion acuosa sobre materiales inorganicos como una funcion del pH

    Energy Technology Data Exchange (ETDEWEB)

    Granados, F.; Bulbulian, S.; Solache R, M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Bertin, V. [UAM-I, 09340 Mexico D.F. (Mexico)

    2004-07-01

    The sorption of the {sup 60} Co is evaluated in aqueous solution on Mg O, MnO{sub 2}, TiO{sub 2}, Sn O, activated carbon and hydrotalcite calcined as a function of the p H, using the method for lots and quantifying at the {sup 60} Co for gamma spectrometry. Likewise it was explained the one behavior of the sorption of the {sup 60} Co in the materials with base in the chemical species of this radioactive isotope in aqueous solution. The chemical species of the {sup 60} Co in solution were identified by electrophoresis of high voltage for the different p H values. It was found that under the experimental conditions, the {sup 60} Co showed a significant sorption on MnO{sup 2}, TiO{sup 2} and activated carbon. On the other hand, in Mg O, Sn O and calcined hydrotalcite also was observed a sorption, although in smaller quantities. The studied hydrated metallic oxides retained the {sup 60} Co for ion exchange via. It was found that the {sup 60} Co was present as a cationic specie to p H 1, 3, 5 and 7 and like a neutral specie to alkaline p H. (Author)

  5. 60Co levels in the seawater regions

    International Nuclear Information System (INIS)

    Yoshioka, Mitsuo

    1983-01-01

    In order to assess the contribution from nuclear power facilities to the 60 Co levels in seawater regions, it is essential to grasp the background values of 60 Co. The following matters are described: 60 Co sources and the respective inputs; nuclear test fallout and nuclear power plants; the 60 Co levels in overseas countries; the 60 Co levels in Japan; the 60 Co levels from nuclear power plants in Fukui prefecture. In the seawater regions around Japan, there have been numerous instances of 60 Co detection; several pCi/kg of dry earth in sea bottom earth and about 1 pCi/kg of raw material in marine life can be considered as the background levels due to nuclear test fallout and nuclear-powered submarines. In the seawater regions of Fukui prefecture, the 60 Co levels appreciably exceeded the above background due to the nuclear power plants, which are insignificant concerning the radiation exposure of the local people. (Mori, K.)

  6. Effect of 60Co gamma radiation on insects infesting rice during storage. Part III. Oryzaephylus surinamensis L., Cryptolestes pusillus S. and Cryptolestes ferrugineus S. (Cucujidae; Coleoptera)

    International Nuclear Information System (INIS)

    Lorenzo, P.

    1997-01-01

    Losses in rice grain in quantity and quality during storage are caused by insects infestations. In this paper the effect of 60 Co gamma radiation on the mortality of Oryzaephilus surinamensis L., Cryptolestes pusillus S. and Cryptolestes ferrugineus S. adults was study. Insects were irradiated with doses from 0,20 to 1,00 kGy at dose rates from 0,97 to 0,94 kGy.h -1 . After the treatment, the radiation damages were evaluated taking in consideration the sterility and mortality produced in the irradiated populations. According to the experimental results it was confirmed that irradiation doses from 0,40 to 0,60 kGy were effective to control the insects pests of stored rice in Cuba [es

  7. On the application of a simple model of cobalt-60 beams

    International Nuclear Information System (INIS)

    Gantchew, M.G.

    1979-01-01

    The simple mathematical model of the dose distribution in a phantom irradiated by a single beam of cobalt-60 gamma rays (Wilks, R.J., and Sutcliffe, J.F., 1977, Phys. Med. Biol., vol. 22, 737) requires measurements for each particular field size and diaphragm setting to describe the decrement functions (dose distributions along a straight line perpendicular to the central ray). Measurements made with a Gammatron-3 have shown satisfactory agreement between computed and measured lateral dose distributions for different diaphragm settings if the experimental data was first subjected to additional processing, and Wilks and Sutcliffe's model can therefore be applied to any diaphragm setting using this modification. Field sizes can therefore be entered according to diaphragm indicator reading in dose planning. (U.K.)

  8. The accumulation and distribution of 60Co in carp (Cyprinus carpio) in water-fish compartment system

    International Nuclear Information System (INIS)

    Poppy Intan Tjahaja; Putu Sukmabuana; Eko Susanto

    2012-01-01

    In relation with nuclear safety assessment, the parameter of radionuclide transfer in the environment is significantly needed for internal doses estimation received by public trough environment - food product - human pathways. International Atomic Energy Agency (IAEA) has published the transfer parameter data for temperate zone in Technical Report Series 472. In order to complete the IAEA data, especially for tropical region, the accumulation and distribution of 60 Co in carp (Cyprinus carpio) was experimentally studied based on the water-fish compartment system. The carp were cultured in 500L water containing 60 Co of about 30 Bq.mL -1 in a water tank. The 60 Co concentration in fish and water were measured using gamma spectrometer. The 60 Co was accumulated and distributed in the fish tissues with the concentration ratio (CR) of 3.08 mL.g -1 1.55 mL.g -1 and 1.14 mL.g -1 for internal organs, bones, and muscle, respectively. The CR of 60 Co in the fish will be useful in internal radiation dose estimation to human trough water-fish-human pathway, and will also complete the IAEA transfer parameter data for tropical region. (author)

  9. Effect of 60Co radiation on peritoneal cells

    International Nuclear Information System (INIS)

    Villavicencio, A.L.C.H.; Mastro, N.L. del.

    1988-07-01

    This work deals with the effect of 60 Co gamma irradiation on the levels and quality of peritoneal cells of albino mice. The cells were obtained from peritoneal exudate, fixed and stained in 30% glacial acetic acid containing 0,5% cristal violet. Os exudates from irradiated and control animals the qualitative analysis and the counting of different cell populations were performed one hour, three days and six days after irradiation with 9 Gy. All the cell populations from the peritoneal exudate shown a decrease 3 days after the irradiation with 9.0. Gy but the different cellular populations dimished in unlike proportions. The data reaffirm the discrepance in radiosensivity of the diverse peritoneal cell populations. (author) [pt

  10. Evaluación no destructiva de la patogenicidad de Cercospora agavicola en vitroplántulas de agave azul tequilero irradiadas con rayos gamma Co60

    OpenAIRE

    Ángeles-Espino, A.; Virgen-Calleros, G.; Valencia-Botín, J.; Ramírez-Serrano, C.; Paredes-Gutiérrez, L.; Hurtado-De la Peña, S.

    2016-01-01

    Resumen: El cultivo del agave y el tequila tienen importancia económica y social por los empleos en campo y la industria, además por las divisas de la exportación. El tizón foliar causado por Cercospora agavicola representa un alto riesgo en la zona de Los Altos de Jalisco, debido a que el clima favorece la dispersión y germinación de las esporas. Se inocularon plántulas obtenidas a partir de yemas axilares, mismas que se irradiaron con rayos gamma Co60 a 0 Gy (testigo), 5 Gy, 10 Gy, 15 Gy, 2...

  11. Enhancement of epoxide hydrolase production by 60 Co gamma and UV irradiation mutagenesis of Aspergillus niger ZJB-09103.

    Science.gov (United States)

    Jin, Huo-Xi; OuYang, Xiao-Kun; Hu, Zhong-Ce

    2017-05-01

    An effective epoxide hydrolase (EH) production strain was mutagenized using 60 Co gamma and UV irradiation. Among positive mutant strains, the EH activity of C2-44 reached 33.7 U/g, which was 267% as much as that of the original Aspergillus niger ZJB-09103. Compared with the wild type, there were significant changes in morphology for C2-44, including the color of mycelia on the slants and the shape of conidial head. In addition, glucose and soybean cake were the optimal carbon and nitrogen source in terms of EH activity for the mutant C2-44 instead of soluble starch and peptone for the wild-type strain. The reaction time required to reach 99% enantiomeric excesses of (S)-epichlorohydrin from racemic substrate was shortened significantly by the mutant C2-44. This phenomenon was probably explained by the higher V max for hydrolysis of racemic epichlorohydrin by C2-44 compared with Aspergillus niger ZJB-09103. © 2016 International Union of Biochemistry and Molecular Biology, Inc.

  12. CO2 laser coating of nanodiamond on aluminum using an annular beam

    International Nuclear Information System (INIS)

    Blum, Rodger; Molian, Pal

    2014-01-01

    Laser coating of nanodiamond (ND) on aluminum alloy A319 substrate was investigated using a diffraction-free ring beam. A 1000 W continuous wave CO 2 laser in the ring beam configuration heated the 25–35 μm thick electrostatically sprayed ND powder layers on aluminum surface, melted a very thin layer (10 μm) of aluminum in a controlled fashion and caused phase transition of ND to form 50–60 μm thick ND/diamond-like carbon (DLC) coating. Significant improvements in friction, wear resistance and surface finish were observed in the ring beam method over the traditional Gaussian beam method suggesting that these thick (50–60 μm) ND/DLC laser coatings can outperform the currently used thin (<4 μm) chemically vapor deposited DLC coatings for aluminum parts in automobiles.

  13. Study of irradiated bothropstoxin-1 with {sup 60}Co gamma rays: immune system behavior

    Energy Technology Data Exchange (ETDEWEB)

    Caproni, P.; Baptista, J.A.; Almeida, T.L. de; Nascimento, N. [Nuclear and Energy Research Institute (IPEN/CNEN-SP), SP (Brazil). Biotechnology Center; Passos, L.A.C. [State University of Campinas (UNICAMP), SP (Brazil). Lab. of Genetics and Embryo Cryopreservation

    2009-07-01

    Ionizing radiation has been successfully employed to modify the immunological properties of biomolecules. Very promising results were obtained when crude animal venoms, as well as isolated toxins, were treated with 60Co gamma rays, yielding toxoids with good immunogenicity. The achievement of modified antigens with lower toxicity and preserved or improved immunogenicity can be very useful. Ionizing radiation has already been proven to be a powerful tool to attenuate snake venom toxicity without affecting, and even increasing, their immunogenic properties. However, little is known about the modifications that irradiated molecules undergo and even less about the immunological response that such antigens elicit. In the present work, we investigated the immunological behavior of bothropstoxin-1, a K49 phospholipase, before and after irradiation. Structural modifications of the toxin were analyzed by SDS-PAGE. Isogenic mice were immunized with either the native or the irradiated toxin. The circulating antibodies were isotyped and titrated by ELISA. According to our data, irradiation promoted structural modifications in the toxin characterized by higher molecular weight forms of proteins (aggregates and oligomers). The results also indicated that irradiated toxins were immunogenic and antibodies elicited by them were able to recognize the native toxin in ELISA. These findings suggest that irradiation of toxic proteins can promote significant modifications in their structures; however they still retain many of the original antigenic and immunological properties of native proteins. Also, our data indicate that irradiated proteins induce higher titers of IgG2a and IgG2b, suggesting that Th1 cells are predominantly involved in the immune response. (author)

  14. Development and evaluation of a technique for in vivo monitoring of 60Co in human liver

    Science.gov (United States)

    Gomes, GH; Silva, MC; Mello, JQ; Dantas, ALA; Dantas, BM

    2018-03-01

    60Co is an artificial radioactive metal produced by activation of iron with neutrons. It decays by beta particles and gamma radiation and represents a risk of internal exposure of workers involved in the maintenance of nuclear power reactors. Intakes can be quantified through in vivo monitoring. This work describes the development of a technique for the quantification of 60Co in human liver. The sensitivity of the method is evaluated based on the minimum detectable effective doses. The results allow to state that the technique is suitable either for monitoring of occupational exposures or evaluation of accidental intakes.

  15. Differential production of proteolytic enzymes by normal human fibroblasts and their counterparts transformed by treatment with 60Co gamma rays

    International Nuclear Information System (INIS)

    Nishitani, Koji; Namba, Masayoshi; Ohkubo, Shigeki; Kimoto, Tetsuo

    1985-01-01

    Production of proteolytic enzymes by human fibroblasts in the process of transformation was investigated. The cells used were normal human fibroblasts (KSM-6) and their in vitro counterparts transformed by treatment with 60 Co gamma rays (KMST-6). Cells seeded by treatment with EDTA were cultured in a serum free medium. Proteolytic enzymes in the culture medium of cells were assayed using a synthetic substrate, N-α-(p-tosyl)-L-arginine ( 3 H) methyl ester hydrochloride. The transformed cells (KMST-6) produced a larger amount of enzymes than normal cells (KMS-6). The enzyme production in both cell lines was high in the exponential growth stage and then decreased as the cells reached confluency. The proteolytic enzymes produced by these cells were trypsin- and thrombin-like enzymes. Cell growth of KMST-6 or KMS-6 was not inhibited by the addition of protease inhibitors to the culture medium. (author)

  16. Gamma and electron beam irradiation effects on SiR-EPDM blends

    Directory of Open Access Journals (Sweden)

    R. Deepalaxmi

    2014-07-01

    Full Text Available Ethylene Propylene Diene Monomer (EPDM is widely used as Cable Insulation Material (CIM due to its good mechanical strength. Silicone Rubber (SiR is used in high temperature environments due to its good di-electric properties/hydrophobicity. The blending of SiR-EPDM may result in the improvement in their specific properties. The SiR-EPDM blend of equal composition (50:50 was prepared. When such blends are used as Cable Insulation Materials (CIM, they should perform their safety functions throughout their installed life in Nuclear Power Plants (NPP. The CIM will be exposed to Gamma irradiation at the installed locations. The short time accelerated testing was carried out, in order to forecast long-term performance of CIM. Electron beam irradiation is widely used in cable manufacturing industries to improve the performance of the polymeric materials. In the current study, on the purpose to investigate the effect of gamma/electron beam irradiation on the 50–50 composition of SiR-EPDM blend, blend was exposed to 25 Mrad dose of gamma/electron beam irradiation. The electrical and mechanical parameters like Volume Resistivity (VRY, Surface Resistivity (SRY, Tensile Strength (TS, Elongation at Break (EB, Hardness (H of the virgin, gamma/electron beam irradiated blends were determined as per ASTM/IEC standards. The nature of degradation was investigated using Fourier Transform Infrared Spectroscopy (FTIR. To determine the elemental composition of the materials at the surface, Energy Dispersive X-ray Analysis (EDAX has been done. Scanning Electron Microscopy (SEM analysis has been done to study the morphological changes. The occurrence of cross-linking is found to be the mechanism for ageing in gamma/electron beam irradiated SiR-EPDM blends.

  17. Effects of single and split doses of cobalt-60 gamma rays and 14 MeV neutrons on mouse stem cell spermatogonia.

    Science.gov (United States)

    Hacker-Klom, U B; Köhnlein, W; Göhde, W

    2000-12-01

    The long-term effects of ionizing radiation on male gonads may be the result of damage to spermatogonial stem cells. Doses of 10 cGy to 15 Gy (60)Co gamma rays or 10 cGy to 7 Gy 14 MeV neutrons were given to NMRI mice as single or split doses separated by a 24-h interval. The ratios of haploid spermatids/2c cells and the coefficients of variation of DNA histogram peaks as measures of both the cytocidal and the clastogenic actions of radiation were analyzed by DNA flow cytometry after DAPI staining. The coefficient of variation is not only a statistical examination of the data but is also used here as a measure of residual damage to DNA (i.e. a biological dosimeter). Testicular histology was examined in parallel. At 70 days after irradiation, the relative biological effectiveness for neutrons at 50% survival of spermatogonial stem cells was 3.6 for single doses and 2.8 for split doses. The average coefficient of variation of unirradiated controls of elongated spermatids was doubled when stem cells were irradiated with single doses of approximately 14 Gy (60)Co gamma rays or 3 Gy neutrons and observed 70 days later. Split doses of (60)Co gamma rays were more effective than single doses, doubling DNA dispersion at 7 Gy. No fractionation effect was found with neutrons with coefficients of variation.

  18. Electron beam sterilization of crude drug and its detection based on genetic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Satake, Motoyoshi; Sekita, Setsuko; Kamakura, Hiroyuki [National Inst. of Health Sciences, Tokyo (Japan)

    2000-02-01

    Chinese traditional crude drugs are medicines derived from natural materials so that most of them include various microorganisms such as soil microbials. Therefore, it is needed to develop a sterilization method for crude drugs not disturbing the efficacy of them. As one of such sterilization method, electron beam sterilization is paid attention now. In this study, the sterilizing effects of electron beam irradiation at various doses were investigated and the changes of low molecular substances were monitored. Phellodendron bark, rehmannia root, bupleurum root and Japanese angelica root samples were used as the subjects. Irradiation was made with {gamma}-ray ({sup 60}Co) and electron beam at 5, 10, 20, 30 and 60 kGy and the number of organisms included in each drug and the contents of effective ingredients were determined after radiation exposure was determined. The number of microbials in these crude drugs were reduced ten times or more by electron beam irradiation, indicating that electron beam exposure has similar effects to those of {gamma}-ray exposure at 10 kGy previously reported. Furthermore, the contents of effective ingredients of crude drugs, especially low molecular substances such as berberine, saponin, catalpol were not significantly changed by the electron beam exposure at the doses tested in this study and electron beam exposure as well as {gamma}-ray exposure hardly affects those ingredients even at 60 kGy. Meanwhile, significant differences were observed in large molecular fractions of gel filtration chromatography between before and after the electron beam exposure at 60 kGy, suggesting that there were structural changes in some large molecules. In addition, to develop a detection method for these crude drugs, genomic DNA was extracted from them and digested with a restriction enzyme, MspI and EcoRI. Then, the ends of the respective DNAs were linked. After amplification by primary PCR, selective PCR was conducted with three MspI primers and Eco

  19. Disturbed tooth formation by 60Co-gamma-ray radiation

    International Nuclear Information System (INIS)

    Doh, Akio

    1982-01-01

    The molar of guinea pigs was irradiated with 60 Co-#betta# ray for daily observations of the manifestation of disturbed tooth formation by microradiography and the time registration by tetracycline-labelling. Irradiation first injured young blast cells of the dentin in the growth phase, dental pulp cells, and cells of the enamel. The portion composed of injured cells formed a depressed ''constriction'' from the dental pulp side toward the border between the enamel and dentin. The cells of the enamel injured by irradiation in the growth phase later formed a very thin irregular stroma. In contrast, cells in the differentiation or subsequent phase at the time of irradiation and cells probably having started to grow after irradiation proceeded with formation of a normal stroma and calcification. No uniform relation was obtained between the histological staining of the organic stroma of normal or abnormal dentin and calcification. Labelling with tetracycline revealed that the irradiation conditions in the present study provoked hardly any changes in the speed of tooth eruption. (Chiba, N.)

  20. Effect of dose fractionation of 60Co gamma radiation on longevity and reproduction of Sitophilus granarius (L., 1785) (Col., Curculionidae) in wheat

    International Nuclear Information System (INIS)

    Arthur, V.; Walder, J.M.M.; Wiendl, F.M.; Domarco, R.E.; Haddad, S.S.

    1987-01-01

    The effects of fractionated doses of gamma radiation in different interval of time on longevity and reproductivity of Sitophilus granarius (L., 1785) are studied. Gamma radiation was provided at dose rate of 1.56 kGy/hour by a Cobalt 60 source (Gammabeam-650). The insects were divided in two sets: one was irradiated at acute doses and the other in fractionated doses, with interval of 48 hours. Both sets received doses of 0,40, 50, 60, 70, 80, 90 and 100Gy. Mortality and and emergency were determined weekly. (M.A.C.) [pt

  1. Relative biological effectiveness (R.B.E.) of Cf-252 vs. acute Co-60 and low dose rate Cs-137 irradiation by spleen weight loss

    International Nuclear Information System (INIS)

    Maruyama, Y.; Feola, J.M.; Magura, C.; Beach, J.L.

    1986-01-01

    R.B.E. of Cf-252 on lymphoid tissue was assessed by radiation study of spleen weight loss following acute Co-60, and low dose rate (L.D.R.) Cs-137 and Cf-252 irradiations. Acute Co-60 and L.D.R. Cs-137 dose-response followed two component exponential curves with a 1.3-fold greater effect of L.D.R. Cs-137 vs. acute Co-60 on the first slope and 1.9-fold greater effect for the 2nd slope. L.D.R. Cf-252 response was 1.3 x greater than acute Co-60 but was 1.0 vs. L.D.R. Cs-137 for the first slope indicating a similar effect of Cf-252 mixed neutron/gamma radiation to L.D.R. gamma radiation in producing spleen shrinkage. There was no effect of different sequences and schedules of mixing acute Co-60 with Cf-252 irradiation observed by endogenous CFU-S survival. The R.B.E. of 1.0 - 1.9 indicates that lymphohemopoietic in vivo, presumably well oxygenated, does not respond acutely or as sensitively as hypoxic tumor where R.B.E. is 5 - 7. (author)

  2. The Co-60 gamma-ray irradiation effects on the Al/HfSiO4/p-Si/Al MOS capacitors

    Science.gov (United States)

    Lok, R.; Kaya, S.; Karacali, H.; Yilmaz, E.

    2017-12-01

    In this work, the initial interface trap density (Nit) to examine device compability for microelectronics and then the Co-60 gamma irradiation responses of Al/HfSiO4/p-Si/Al (MOS) capacitors were investigated in various dose ranges up to 70 Gy. Pre-irradiation response of the devices was evaluated from high frequency (HF) and low frequency (LF) capacitance method and the Nit was calculated as 9.91 × 1011 cm-2 which shows that the HfSiO4/p-Si interface quality is convenient for microelectronics applications. The irradiation responses of the devices were carried out from flat-band and mid-gap voltage shifts obtained from stretch of capacitance characteristics prior to and after irradiation. The results show that the flat band voltages very slightly shifted to positive voltage values demonstrating the enhancement of negative charge trapping in device structure. The sensitivity of the Al/HfSiO4/p-Si/Al MOS capacitors was found to be 4.41 mV/Gy for 300 nm-thick HfSiO4 gate dielectrics. This value approximately 6.5 times smaller compared to the same thickness conventional SiO2 based MOS devices. Therefore, HfSiO4 exhibits crucial irradiation tolerance in gamma irradiation environment. Consequently, HfSiO4 dielectrics may have significant usage for microelectronic technology as a radiation hard material where radiation field exists such as in space applications.

  3. Study on adsorption of 60Co in soils and minerals and transportation of 60Co in bean-soil system

    International Nuclear Information System (INIS)

    Feng Yonghong; Chen Chuanqun; Wang Shouxiang; Zhang Yongxi; Sun Zhiming

    1998-02-01

    The adsorption and desorption of 60 Co in soils and minerals, and the transportation, accumulation, distribution in bean-soil system are studied. The results are as follows: (1) 60 Co was adsorbed rapidly and desorbed difficultly by soils and minerals. The order of the saturated adsorption rate and K d (distribution coefficient) of 60 Co at the balance value was: kieselguhr>paddy soil (loamy clay)>yellowish red soil>kaoline>perlite>silt-loamy soil. The order of D f (desorption factor) value was: yellowish red soil>silt-loamy soil>kaoline>perlite>paddy soil (loamy clay)>kieselguhr. The dynamic behavior of 60 Co in the soils and minerals could be described as a closed two--compartment model. (2) After 60 Co was introduced to the bean-soil system, the concentration of 60 Co in the root is about 10.4∼23.3 times of that in the stalk, and 30 times of that in the bean pod. The negative correlation between the concentration of 60 Co in the soil and depth was detected, over 90 per cent of 60 Co was retained within 6 centimeters of the surface layer, the half residual depth was 2 centimeters. An opened two-compartment model was applied to describe the behavior of 60 Co in the bean-soil system

  4. Development of irradiator {sup 60}Co sources

    Energy Technology Data Exchange (ETDEWEB)

    Mosca, Rodrigo C.; Moura, Eduardo S.; Zeituni, Carlos A.; Mathor, Monica B., E-mail: rcmosca@usp.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    According to a recent report by the International Agency for Research on Cancer (IARC) / WHO (2008-2010), the global impact of cancer more than doubled in 30 years. In this report, it was estimated that occurred about 12 million new cancer cases and 7 million deaths. In Brazil in 2010, with estimates for the year 2011, point to the occurrence of 489,270 new cases of cancer. Among the possibilities for cancer treatment, radiotherapy is one of the most important therapeutic and resources used to combat it. However, inherent complications of treatment can occur such as tiredness, loss of appetite, radiodermatitis and in more extreme cases late radionecrosis. In order to reproduce a point of radionecrosis in the vicinity of radiodermatitis to mimic these effects in animals, producing a model for assessment of tissue repair, we propose the setting up of an irradiator source of collimated {sup 60}Co. The development of was based on 11 sources of {sup 60}Co with 1 mm thickness that were inserted by inference in stainless steel 'gate-source' screw (patent pending) and later adjusted in a cross-shaped arrangement reinforced so that the beam radiation is directed to a target point, saving for other regions around this target point. The main use of this irradiator with sources of {sup 60}Co is just one cause radionecrosis point (target point) of approximately 5 mm{sup 2} with a surrounding and adjacent area of radiodermatitis around about 8 to 10 mm{sup 2} in laboratory animals for subsequent coating with epidermal-dermal matrix populated by a cell culture of human fibroblasts, keratinocytes and mesenchymal stem cells. With that said, its use will be valuable for evaluation of curative treatments against the bone and radionecrosis or palliative treatment rather than as it is currently assumed. (author)

  5. The international protocol for the dosimetry of external radiotherapy beams based on standards of absorbed dose to water

    International Nuclear Information System (INIS)

    Andreo, P.

    2001-01-01

    An International Code of Practice (CoP, or dosimetry protocol) for external beam radiotherapy dosimetry based on standards of absorbed dose to water has been published by the IAEA on behalf of IAEA, WHO, PAHO and ESTRO. The CoP provides a systematic and internationally unified approach for the determination of the absorbed dose to water in reference conditions with radiotherapy beams. The development of absorbed-dose-to-water standards for high-energy photons and electrons offers the possibility of reducing the uncertainty in the dosimetry of radiotherapy beams. Many laboratories already provide calibrations at the radiation quality of 60Co gamma-rays and some have extended calibrations to high-energy photon and electron beams. The dosimetry of kilovoltage x-rays, as well as that of proton and ion beams can also be based on these standards. Thus, a coherent dosimetry system based on the same formalism is achieved for practically all radiotherapy beams. The practical use of the CoP as simple. The document is formed by a set of different CoPs for each radiation type, which include detailed procedures and worksheets. All CoPs are based on ND,w chamber calibrations at a reference beam quality Qo, together with radiation beam quality correction factors kQ preferably measured directly for the user's chamber in a standards laboratory. Calculated values of kQ are provided together with their uncertainty estimates. Beam quality specifiers are 60Co, TPR20,10 (high-energy photons), R50 (electrons), HVL and kV (x-rays) and Rres (protons and ions) [es

  6. Effects on artificial blood substitute (Fluosol-DA) by 60Co gamma-ray irradiation

    International Nuclear Information System (INIS)

    Hishikawa-Itoh, Youko; Ayakawa, Yoshio; Miyata, Nobuki

    1982-01-01

    It had been demonstrated the high oxygen solubility of perfluorochemical emulsion (Fluosol-DA), and Fluosol-DA is going to apply as an oxygen carrier, namely artificial blood substitutes for clinical application. There have been many reports on physical, chemical and biological aspects of Fluosol-DA, but not have been reported on irradiation effects. In this paper, we investigated the effects on Fluosol-DA by 60 Co γ-ray irradiation. 1. pH of Fluosol-DA was increased apparently, this effect was not by irradiation, but by thermal effect. 2. Optical density of Fluosol-DA at 620 nm which meaned an effect on particles of Fluosol-DA was not changed by γ-irradiation. 3. F - ion concentration of Fluosol-DA which meaned an effect on structure of perfluorochemical was not changed merkedly. 4. The solubility of oxygen of Fluosol-DA was slightly increased by γ-irradiation at 25 0 C and 11 0 C, but this effect was disregarded. These results suggested that 60 Co γ-irradiation did not effect on pH, size or aggregation of particles, release of F - ion from Fluosol-DA and solubility of oxygen of Fluosol-DA. (author)

  7. Experimental determination of gamma radiation effect from cobalt 60 on the viscosity of SSBR-B polymer

    International Nuclear Information System (INIS)

    Santos, L.G. dos; Silva Filho, E.

    1989-01-01

    Samples of the polymer known as SSBR-B (Solution Styrenne Butadiene Rubber-Blockade) were irradiated with gamma rays from a 60 Co source. Viscosity analysis performed by using the method of Ostwald Showed that the viscosity remains about constant for doses in the range of zero to 11560 Gray (Gy). For doses greater than 11560 Gy the viscosity increases. This result characterizes an irradiation induced hardening of the polymer. (author) [pt

  8. Biochemical and pharmacological studies of native and irradiated crotamine with gamma radiation of Co60

    International Nuclear Information System (INIS)

    Mitake, M.B.

    2000-01-01

    Ionizing radiation can change the molecular structure and affect the biological properties of biomolecules. This has been employed to attenuate animal toxins. Crotamine is a strongly basic polypeptide from South American rattlesnake venom, composed of 42 amino acid residues. It induces skeletal muscle spasms, leading to a spastic paralysis of hind limbs in mice. The objective was to carry out biochemical and pharmacological studies of native and irradiated crotamine with Co. Crotamine was purified from Crotalus durissus terrificus venom by Sephadex G-100 gel filtration followed by ion exchange chromatography, using a Fast performance Liquid Chromatography (FPLC) system. It was irradiated at 2 mg/ml in 0.15 m NaCl with 2.0 kGy gamma radiation emitted by a Co source. Native and irradiated crotamine were evaluated by biochemical characterization, toxic activity (LD50), and biodistribution. The native and irradiated crotamine were labeled with 29.6 MBq of I using chloramine T method and separated in a Sephadex G-50 column. Male Swiss mice (35 @ 5 g) were injected IP with 0.1 mL (2.4x10 cpm/mouse) of I native crotamine or with 0.4 mL (1.3 x 10 cpm/mouse) of I irradiated crotamine. The animals were sacrificed by ether inhalation at 0.08, 0.25, 0.5,1, 2, 3, 4, 8, 12, and 24 hours. Blood, spleen, liver, kidneys, brain, lungs, heart, and skeletal muscle were collected in order to determine radioactivity content. The results showed that gamma radiation did not change protein concentration, electrophoretic profile, or protein primary structure, although differences could be seen by spectroscopic techniques. Gamma radiation reduced crotamine toxicity, but did not eliminate bioactivity. Biodistribution studies showed that native and irradiated crotamine have hepatic metabolism and renal elimination. Native and irradiated crotamine have an affinity to skeletal muscle and did not cross the blood-brain barrier. (author)

  9. The structure of neutron-rich nuclei explored via in-beam gamma-ray spectroscopy of fast beams

    International Nuclear Information System (INIS)

    Glasmacher, T.; Campbell, C.M.; Church, J.A.; Dinca, D.C.; Hansen, P.G.; Olliver, H.; Perry, B.C.; Sherrill, B.M.; Terry, J.R.; Bazin, D.; Enders, J.; Gade, A.; Hu, Z.; Mueller, W.F.

    2003-01-01

    In-beam gamma-ray spectroscopy with fast exotic beams provides an efficient tool to study bound states in exotic neutron-rich nuclei. Specialized experimental techniques have been developed and explore different aspects of nuclear structure. Inelastic scattering experiments with γ-ray detection can measure the response of exotic nuclei to electromagnetic (Coulomb excitation with a heavy target) or hadronic probes (proton scattering with hydrogen target). In-beam fragmentation populates higher-lying bound states to establish levels. Single- and two-nucleon knockout reactions allow for detailed wavefunction spectroscopy of individual levels and for the measurement of spectroscopic factors. Experimental programs employing these techniques are now underway at all projectile-fragmentation facilities around the world. Here we report on several successful in-beam gamma-ray spectroscopy experiments that have been performed at the Coupled Cyclotron Facility at Michigan State University with an emphasis on elucidating the evolution of nuclear structure around neutron numbers N=16, N=20, and N=28 in the π(sd) shell. (orig.)

  10. BaSO4:Eu as an energy independent thermoluminescent radiation dosimeter for gamma rays and C6+ ion beam

    Science.gov (United States)

    Sharma, Kanika; Bahl, Shaila; Singh, Birendra; Kumar, Pratik; Lochab, S. P.; Pandey, Anant

    2018-04-01

    BaSO4:Eu nanophosphor is delicately optimized by varying the concentration of the impurity element and compared to the commercially available thermoluminescent dosimeter (TLD) LiF:Mg,Ti (TLD-100) and by extension also to CaSO4:Dy (TLD-900) so as to achieve its maximum thermoluminescence (TL) sensitivity. Further, the energy dependence property of this barite nanophosphor is also explored at length by exposing the phosphor with 1.25 MeV of Co-60, 0.662 MeV of Cs-137, 85 MeV and 65 MeV of Carbon ion beams. Various batches of the phosphor at hand (with impurity concentrations being 0.05, 0.10, 0.20, 0.50 and 1.00 mol%) are prepared by the chemical co-precipitation method out of which BaSO4:Eu with 0.20 mol% Eu exhibits the maximum TL sensitivity. Further, the optimized nanophosphor exhibits a whopping 28.52 times higher TL sensitivity than the commercially available TLD-100 and 1.426 times higher sensitivity than TLD-900, a noteworthy linear response curve for an exceptionally wide range of doses i.e. 10 Gy to 2 kGy and a simple glow curve structure. Furthermore, when the newly optimized nanophosphor is exposed with two different energies of gamma radiations, namely 1.25 MeV of Co-60 (dose range- 10-300 Gy) and 0.662 MeV of Cs-137 (dose range- 1-300 Gy), it is observed that the shape and structure of the glow curves remain remarkably similar for different energies of radiation while the TL response curve shows little to no variation. When exposed to different energies of carbon ion beam BaSO4:Eu displays energy independence at lower doses i.e. from 6.059 to 14.497 kGy. Finally, even though energy independence is lost at higher doses, the material shows high sensitivity to higher energy (85 MeV) of carbon beam compared to the lower energy (65 MeV of C6+) and saturation is apparent only after 121.199 kGy. Therefore the present nanophosphor displays potential as an energy independent TLD.

  11. Resveratrol effects on life span and fertility of caenorhabditis elegans subject to 60Co gamma ray irradiation

    International Nuclear Information System (INIS)

    Ye Kai; Ji Chenbo; Guo Xirong; Gu Guixiong

    2011-01-01

    Caennorhabditis elegans was used as experimental model to investigate radiation effect of resveratrol on caenorhabditis elegans irradiated by 60 Co γ ray. Treatment with resveratrol can increase average life span and spawning rate, improve the survival rate of eggs, and protect their mitochondrion function of caenorhabditis elegans exposure to 60 Co γ ray. The results indicate that resveratrol has radiation protection effects, which might be related to its action on ROS decrease and mitochondrial defend. (authors)

  12. Measurements of lattice and grain boundary diffusivities of 60Co and 54Mn in type 316 stainless steel

    International Nuclear Information System (INIS)

    Polley, M.V.

    1981-02-01

    Diffusion in type 316 stainless steel was studied by depositing 60 Co and 54 Mn on flat polished surfaces and heating. Diffusion profiles, obtained after gamma-counting slices removed by hand grinding, were analysed using Suzuoka's ''instantaneous source'' model. (author)

  13. Scanning of Cargo Containers by Gamma-Ray and Fast Neutron Radiography

    International Nuclear Information System (INIS)

    Yousri, A.M.; Bashter, I.I.; Megahid, M.R.; Osman, A.M.; Kansouh, W.A.; Reda, A.M.

    2011-01-01

    This paper describes the combined systems which were installed and tested to detect contraband smuggled in cargo containers. These combined systems are based on radiographers work by gamma-rays emitted from point source 60 Co with 0.5 Ci activity and neutrons emitted from point isotopic sources of Pu-α-Be as well as 14 MeV neutrons emitted from sealed tube neutron generator. The transmitted gamma ray through the inspected object was measured by gamma detection system with NaI(Tl) detector while the transmitted fast neutron beam was measured by a neutron gamma detection system with stilbene organic scintillator. The later possess the capability of discrimination between between gamma and neutron pulses using a discrimination system based on pulse shape discrimination method. The measured intensities of primary incident and transmitted beams of gamma-rays and fast neutrons were used to construct 2D cross-sectional images of the inspected objects hidden directly within benign materials of the container and for object screened by high dense material to stop object detection by gamma or X-rays. The constructed images for the inspected objects show the good capability and effectiveness of the installed gamma and neutron radiographers to detect illicit materials hidden in air cargo containers and sea containers of med size. They have also indicated that the developed scanning systems possess the ease of mobility and low cost of scanning

  14. Development and evaluation of a technique for in vivo monitoring of {sup 60}Co in human liver

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, B.M.; Dantas, A.L.A.; Gomes, G.H.; Silva, M.C.; Mello, J.Q., E-mail: bmdantas@ird.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    {sup 60}Co is an artificial radioactive metal produced by activation of iron with neutrons. It decays by beta particles and gamma radiation and represents a risk of internal exposure of workers involved in the maintenance of nuclear power reactors. Intakes can be quantified through in vivo monitoring. This work describes the development of a technique for the quantification of {sup 60}Co in human liver. The sensitivity of the method is evaluated based on the minimum detectable effective doses. The results allow to state that the technique is suitable either for monitoring of occupational exposures or evaluation of accidental intakes. (author)

  15. A compact neutron beam generator system designed for prompt gamma nuclear activation analysis.

    Science.gov (United States)

    Ghassoun, J; Mostacci, D

    2011-08-01

    In this work a compact system was designed for bulk sample analysis using the technique of PGNAA. The system consists of (252)Cf fission neutron source, a moderator/reflector/filter assembly, and a suitable enclosure to delimit the resulting neutron beam. The moderator/reflector/filter arrangement has been optimised to maximise the thermal neutron component useful for samples analysis with a suitably low level of beam contamination. The neutron beam delivered by this compact system is used to irradiate the sample and the prompt gamma rays produced by neutron reactions within the sample elements are detected by appropriate gamma rays detector. Neutron and gamma rays transport calculations have been performed using the Monte Carlo N-Particle transport code (MCNP5). 2010 Elsevier Ltd. All rights reserved.

  16. CO{sub 2} laser coating of nanodiamond on aluminum using an annular beam

    Energy Technology Data Exchange (ETDEWEB)

    Blum, Rodger; Molian, Pal, E-mail: molian@iastate.edu

    2014-01-01

    Laser coating of nanodiamond (ND) on aluminum alloy A319 substrate was investigated using a diffraction-free ring beam. A 1000 W continuous wave CO{sub 2} laser in the ring beam configuration heated the 25–35 μm thick electrostatically sprayed ND powder layers on aluminum surface, melted a very thin layer (10 μm) of aluminum in a controlled fashion and caused phase transition of ND to form 50–60 μm thick ND/diamond-like carbon (DLC) coating. Significant improvements in friction, wear resistance and surface finish were observed in the ring beam method over the traditional Gaussian beam method suggesting that these thick (50–60 μm) ND/DLC laser coatings can outperform the currently used thin (<4 μm) chemically vapor deposited DLC coatings for aluminum parts in automobiles.

  17. The effect of build-up cap materials on the response of an ionization chamber to 60Co gamma rays

    International Nuclear Information System (INIS)

    Rocha, M.P.O.; Almeida, C.E. de

    1993-01-01

    Knowledge of the effect of wall and build-up cap materials on ionization chamber response is necessary to determine absorbed dose in a medium using a calibration factor based on exposure or kerma in air. Attenuation and scattering effects of 60 Co gamma rays in the ionization chamber wall and build-up cap, as well as their non-equivalence to air, were studied with an OFS ionization chamber (Delrin wall) and a set of build-up caps specially built for this purpose. Results for a specific material were plotted as functions of wall and cap total thickness, extrapolated to zero wall thickness, then corrected for mean centre of electron production in the wall (= 0.136 g cm -2 ). Correction factors for a specific thickness were analysed in relation to cap material, and to relative responses compared with values calculated by using AAPM, SEFM and IAEA formalisms for cap effects. A Monte Carlo calculation was performed to compare the experimental and theoretical values. Calculations showed an agreement within 0.1% with experimental values and a wall effect of approximately 1.6%. (Author)

  18. Measurements of 60Co in spoons activated by neutrons during the JCO criticality accident at Tokai-mura in 1999.

    Science.gov (United States)

    Gasparro, J; Hult, M; Komura, K; Arnold, D; Holmes, L; Johnston, P N; Laubenstein, M; Neumaier, S; Reyss, J-L; Schillebeeckx, P; Tagziria, H; Van Britsom, G; Vasselli, R

    2004-01-01

    Neutron activated items from the vicinity of the place where the JCO criticality accident occurred have been used to determine the fluence of neutrons around the facility and in nearby residential areas. By using underground laboratories for measuring the activation products, it is possible to extend the study to also cover radionuclides with very low activities from long-lived radionuclides. The present study describes gamma-ray spectrometry measurements undertaken in a range of underground laboratories for the purpose of measuring (60)Co more than 2 years after the criticality event. The measurements show that neutron fluence determined from (60)Co activity is in agreement with previous measurements using the short-lived radionuclides (51)Cr and (59)Fe. Limits on contamination of the samples with (60)Co are evaluated and shown to not greatly affect the utility of neutron fluence determinations using (60)Co activation.

  19. Shielding requirements on-site loading and acceptance testing on the Leksell gamma knife

    International Nuclear Information System (INIS)

    Maitz, A.H.; Lunsford, L.D.; Wu, A.; Lindner, G.; Flickinger, J.C.

    1990-01-01

    On August 14, 1987, the first stereotactic radiosurgical procedure using the gamma knife was performed in North America. Located in a self-contained radiosurgical suite in the basement of Presbyterian-University Hospital in Pittsburgh, Pennsylvania. This device uses 201 highly focused beams 60Co for the single-treatment closed-skull irradiation of brain lesions localized by stereotactic techniques (radiosurgery). One hundred and fifty-two patients with intracranial arteriovenous malformations or brain tumors were treated in the first year of operation. The Presbyterian University Hospital of Pittsburgh gamma knife is the first such unit in which the 60Co sources were loaded on-site. This effort required us to solve some difficult and unusual problems encountered during site preparation, delivery, and loading of the unit in a busy hospital setting. The solutions developed enabled installation and use of the gamma knife with minimal disruption of hospital activities while maintaining acceptable levels of exposure to radiation. Environmental surveys performed during the loading of the 201 radioactive sources (total, 219 TBq) confirmed that on-site loading is possible and practical. Our experience in the design, construction, and implementation of the first North American gamma knife supports the practicality and safety of on-site loading and may be of value in the planning and development of future gamma knife installations

  20. Muon Beam Studies in the H4 beam line and the Gamma Irradiation Facility (GIF++)

    CERN Document Server

    Margraf, Rachel; CERN. Geneva. EN Department

    2017-01-01

    In this report, I summarize my work of detailed study and optimization of the muon beam configuration of H4 beam line in SPS North Area. Using Monte-Carlo simulations, I studied the properties and behavior of the muon beam in combination with the field of the large, spectrometer “ GOLIATH” magnet at -1.5, -1.0, 0, 1.0 and 1.5 Tesla, which is shown to affect the central x position of the muon beam that is delivered to the Gamma Irradiation Facility (GIF++). I also studied the muon beam for different configurations of the two XTDV beam dumps upstream of GIF++ in the H4 beam line. I will also discuss my role in mapping the magnetic field of the GOLIATH magnet in the H4 beam line.

  1. Neutron beam design for low intensity neutron and gamma-ray radioscopy using small neutron sources

    CERN Document Server

    Matsumoto, T

    2003-01-01

    Two small neutron sources of sup 2 sup 5 sup 2 Cf and sup 2 sup 4 sup 1 Am-Be radioisotopes were used for design of neutron beams applicable to low intensity neutron and gamma ray radioscopy (LINGR). In the design, Monte Carlo code (MCNP) was employed to generate neutron and gamma ray beams suited to LINGR. With a view to variable neutron spectrum and neutron intensity, various arrangements were first examined, and neutron-filter, gamma-ray shield and beam collimator were verified. Monte Carlo calculations indicated that with a suitable filter-shield-collimator arrangement, thermal neutron beam of 3,900 ncm sup - sup 2 s sup - sup 1 with neutron/gamma ratio of 7x10 sup 7 , and 25 ncm sup - sup 2 s sup - sup 1 with very large neutron/gamma ratio, respectively, could be produced by using sup 2 sup 5 sup 2 Cf(122 mu g) and a sup 2 sup 4 sup 1 Am-Be(37GBq)radioisotopes at the irradiation port of 35 cm from the neutron sources.

  2. Gamma spectrometry on MANITU 271-01 gamma scan wires

    International Nuclear Information System (INIS)

    Dassel, G.; Buurveld, H.A.; Minkema, J.

    1994-08-01

    A series of irradiation experiments (271-series) is being performed of the sustain programme for material development and characterization of the NET (Next European Torus). In the framework of the first irradiation experiment 271-01, with irradiation up to 0.2 dpa, four gamma scan wires have been examined by gamma scanning. The purpose of the gamma scan wires (GSW) is to get information about the neutron fluence distribution in the capsules during irradiation. In the stainless steel wires the nuclides Co-58, Mu-54, Fe-59 and Co-60 are produced, are characteristic for fast and thermal neutron reactions. (orig./HP)

  3. Comparison of the standards for absorbed dose to water of the VNIIFTRI, Russia and the BIPM in {sup 60}Co gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Allisy-Roberts, P.J.; Kessler, C.; Burns, D.T. [Bureau International des Poids et Mesures (BIPM), 92 - Sevres (France); Berlyand, V.; Berlyand, A. [All-Russian Scientific Research Institute for Physical-Technical and Radiotechnical Measurements, Moscow (Russian Federation)

    2010-02-15

    A new comparison of the standards for absorbed dose to water of the All-Russian Scientific Research Institute for Physical-Technical and Radio-technical Measurements (VNIIFTRI), Russia and of the Bureau International des Poids et Mesures (BIPM) has been made in {sup 60}Co gamma radiation in 2009. The results show that the VNIIFTRI and the BIPM standards for absorbed dose to water are in agreement, yielding a mean ratio of 0.9976 for the calibration coefficients of the transfer chambers, the difference from unity being within the combined standard uncertainty (0.0043) for this result. This result is consistent with the earlier 2001 comparison result of 0.9967 (43). The updated degrees of equivalence for the VNIIFTRI are compared with those of the other national metrology institutes as presented in the BIPM key comparison database. (authors)

  4. SU-E-T-94: An Advanced Rotating Gamma Ray System for Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Ma, C; Chibani, O; Li, J; Chen, L [Fox Chase Cancer Center, Philadelphia, PA (United States); Mora, G [Universidade de Lisboa, Codex, Lisboa (Portugal)

    2015-06-15

    Purpose: Co-60 beams have unique dosimetric properties that are ideally suited for cranial treatments. Co-60 sources with cone-shaped collimators provide conformal dose distributions allowing for ablative treatments with rapid dose falloff to spare nearby critical structures. This work investigates a novel, image-guided, rotational Gamma ray system that provides both superior dose conformity/gradient and accurate stereotaxy for stereotactic radiosurgery (SRS). Methods: The SupeRay system (Cyber Medical Corp., China) consists of a rotating source chamber containing 30 gamma sources focusing at the isocenter with 4 collimators measuring 3, 4, 8 and 16mm in diameter. A novel switch design enables the 30 Gamma sources to be turned off at any arbitrarily selected 60° interval in order to avoid critical structures. The 3D treatment couch provides automatic treatment positioning between individual shots and the kV imaging system provides orthogonal images with a spatial resolution of 0.24mm to facilitate target localization. Monte Carlo simulations were used to compute dose distributions and compare with measurements and other Gamma ray SRS systems. Results: Monte Carlo results confirmed the SupeRay design parameters including output factors and 3D dose distributions. Its beam penumbra/dose gradient is similar to or slightly better than that of the Elekta Gamma Knife. The penumbra in the (x,y,z) direction was (7.38mm,7.38mm,3.86mm) for the 16mm collimator, (4.83mm,4.83mm,3.12mm) for the 8mm collimator, and (3.03mm,3.03mm,2.38mm) for the 4mm collimator, respectively, on the SupeRay system while it was (9.5mm,10.0mm,2.9mm), (4.3mm,4.3mm,2.9mm) and (3.2mm,3.2mm,1.9mm) for the same collimator sizes, respectively, on the Perfexion system. The kV imaging system together with a non-invasive relocatable frame provides accurate target localization (<0.5mm) for cases requiring multiple treatment fractions. Conclusion: Because of the unique dosimetric properties of Co-60 sources

  5. Load of Co-60 in large gamma irradiators: a safe proceeding

    International Nuclear Information System (INIS)

    Luca, Gilmara C.; Paquer, Daniela

    2011-01-01

    The inclusion of new Co-60 sources in industrial irradiators is an extra procedure to its operation and extremely critical. The operation requires planning, attention, responsibility and a well trained staff. Radiation level, package contamination and radioactive material escape evaluations are essential as measurement of pre-loading safety. The package transfer for the swimming pool i e the most critical moment of the operation. After sources transfer to the racks, it is necessary the monitoring of tools, package and sources through the scrubbing test. Notwithstanding to be a critical operation, the risk is minimized when it is performed according to safe rules and radiation protection, and in the process performed the individual accumulated doses does not exceed 50 to μSv

  6. Ambient-temperature diffusion and gettering of Pt atoms in GaN with surface defect region under 60Co gamma or MeV electron irradiation

    Science.gov (United States)

    Hou, Ruixiang; Li, Lei; Fang, Xin; Xie, Ziang; Li, Shuti; Song, Weidong; Huang, Rong; Zhang, Jicai; Huang, Zengli; Li, Qiangjie; Xu, Wanjing; Fu, Engang; Qin, G. G.

    2018-01-01

    Generally, the diffusion and gettering of impurities in GaN needs high temperature. Calculated with the ambient-temperature extrapolation value of the high temperature diffusivity of Pt atoms in GaN reported in literature, the time required for Pt atoms diffusing 1 nm in GaN at ambient temperature is about 19 years. Therefore, the ambient-temperature diffusion and gettering of Pt atoms in GaN can hardly be observed. In this work, the ambient-temperature diffusion and gettering of Pt atoms in GaN is reported for the first time. It is demonstrated by use of secondary ion mass spectroscopy that in the condition of introducing a defect region on the GaN film surface by plasma, and subsequently, irradiated by 60Co gamma-ray or 3 MeV electrons, the ambient-temperature diffusion and gettering of Pt atoms in GaN can be detected. It is more obvious with larger irradiation dose and higher plasma power. With a similar surface defect region, the ambient-temperature diffusion and gettering of Pt atoms in GaN stimulated by 3 MeV electron irradiation is more marked than that stimulated by gamma irradiation. The physical mechanism of ambient-temperature diffusion and gettering of Pt atoms in a GaN film with a surface defect region stimulated by gamma or MeV electron irradiation is discussed.

  7. Operation and Development on the Positive-Ion Based Neutral Beam Injection System for JT-60 and JT-60U

    International Nuclear Information System (INIS)

    Kuriyama, M.; Akino, N.; Ebisawa, N.; Honda, A.; Itoh, T.; Kawai, M.; Mogaki, K.; Ohga, T.; Oohara, H.; Umeda, N.; Usui, K.; Yamamoto, M.; Yamamoto, T.; Matsuoka, M.

    2002-01-01

    The positive-ion based neutral beam injection (NBI) system for JT-60, which consists of 14 beamline units and has a beam energy of 70 to 100 keV, started operation in 1986 with hydrogen beams and injected a neutral beam power of 27 MW at 75 keV into the JT-60 plasma. In 1991, the NBI system was modified to be able to handle deuterium beams as part of the JT-60 upgrade modification. After executing some research and developments, deuterium beams of 40 MW at 95 keV were injected in 1996. As a result, NBI has contributed to the achievement of the highest performance plasmas, a DT-equivalent fusion power gain of 1.25 and a fusion triple product of 1.55 x 10 21 keVs/m 3 , in the world on JT-60U

  8. Effect of gamma radiation (60Co) on the growth of Aspergillus ochraceus coffee (Coffea arabica L.)

    International Nuclear Information System (INIS)

    Rodrigues, Flavio T.; Duarte, Renato C.; Fanaro, Gustavo B.; Santillo, Amanda G.; Villavicencio, Anna Lucia C.H.

    2011-01-01

    Coffee is a major product on the world market. Its acceptance depends strongly on the sensory characteristics of the beverage, that is its aroma and flavor. One of the most important aspects of coffee culture today is the cup quality as such all segments of coffee production network are concentrating efforts to improve this trait. Foods that have been contaminated with fungi may contain may produce many mycotoxins including ochratoxim A (OTA). To prevent OTA in foodstuffs, it is necessary detect the producing fungi early. Ionizing radiation is a safe, environmentally clean, energy efficient process that can be used to increase the quality and reducing the microbiological contamination of the coffee. The aim of the present study was to evaluate the effects of different gamma radiation doses (0.0, 6.0, 12.0 and 18.0 kGy) on the growth of Aspergillus ochraceus in coffee (Coffee arabica L.). The analysis were performed to determine the fungi contamination the results were expressed as the viable counts per gram of sample (CFU/g) coffee samples irradiated and unirradiated. The results shows that microbiological contamination of coffee disagrees when increase doses of irradiation. The radiation doses 6.0, 12.0 and 18.0 kGy used resulted in a elimination of the number of Aspergillus ochraceus CFU/g when compared to the nonirradiated control group. Under the present conditions, gamma radiation was found to be an alternative for the control of Aspergillus ochraceus. (author)

  9. High-$\\gamma$ Beta Beams within the LAGUNA design study

    CERN Document Server

    Orme, Christopher

    2010-01-01

    Within the LAGUNA design study, seven candidate sites are being assessed for their feasibility to host a next-generation, very large neutrino observatory. Such a detector will be expected to feature within a future European accelerator neutrino programme (Superbeam or Beta Beam), and hence the distance from CERN is of critical importance. In this article, the focus is a $^{18}$Ne and $^{6}$He Beta Beam sourced at CERN and directed towards a 50 kton Liquid Argon detector located at the LAGUNA sites: Slanic (L=1570 km) and Pyh\\"{a}salmi (L=2300 km). To improve sensitivity to the neutrino mass ordering, these baselines are then combined with a concurrent run with the same flux directed towards a large Water \\v{C}erenkov detector located at Canfranc (L=650 km). This degeneracy breaking combination is shown to provide comparable physics reach to the conservative Magic Baseline Beta Beam proposals. For $^{18}$Ne ions boosted to $\\gamma=570$ and $^{6}$He ions boosted to $\\gamma=350$, the correct mass ordering can be...

  10. Contribution to the study of the behaviour of silicon planar transistors exposed to the {sup 60}Co {gamma} rays; Contribution a l'etude du comportement des transistors silicium a structure plane soumis aux rayons {gamma} du {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Le Ber, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-05-15

    This report gives an account of studies carried out on bipolar silicon planar transistors irradiated by {sup 60}Co {gamma} rays. The author describes the interactions on the matter of the different types of particles and he gives a brief bibliographical recall of foreign studies. The technological structure of the planar transistors is then described in order to help the understanding of the phenomena, general comments are made about the choice of measured parameters and on the statistical interpretation of results. An automatic instrument for the measurement of the gain is described and the reproducibility of the results is stated The complexity of the problem and the difficulty to predict the behaviour of the semiconductors components are clearly shown. It is stated that the observed dispersions depend on: - the electrical bias during irradiation - the injection level in the emitter-base junction during the measurement - the manufacturer for a given type - the instantaneous dose rate - the geometry used The problem is then examined from the reliability point of view and methods are given to evaluate the reliability for a given dose - 'Worst case' method - moment method - Monte Carlo method. (author) [French] Ce rapport rend compte du travail effectue sur les transistors bipolaires au silicium irradies au rayons {gamma} du cobalt 60. On passe en revue les mecanismes d'interaction des differents rayonnements avec la matiere et on fait un bref rappel bibliographique des etudes effectuees a l'etranger. On decrit ensuite la structure technologique du transistor pour aider a la comprehension des phenomenes, puis on donne des generalites sur le choix des parametres mesures et l'interpretation statistique des resultats. On decrit l'ensemble du systeme de mesure de gain et on s'attache a montrer la reproductibilite des mesures. Les resultats experimentaux mentionnes etablissent clairement la complexite du probleme et la difficulte qu'il y a de faire des previsions. On

  11. 氮离子束注入和钴60伽玛辐射对大豆产量性状和品质的影响%Effects of Nitrogen Ion Beam Implantation and 60Co-γ Irradiation on Yield Traits and Quality of Soybean

    Institute of Scientific and Technical Information of China (English)

    季良; 王仙; 彭琳; 聂石辉

    2013-01-01

    Selection of materials, mutagenic methods and doses are very important in mutation breeding. The objectives of this experiment was to discuss the mutation breeding technique of soybean by nitrogen ion beam implantation and 60Co-γ ray radiation. The dried seeds of four soybean varieties were treated by nitrogen ion beam implantation including 4 × 1016 ,6 × 1016 and 8 × 1016 N+ ·cm-2 and 60Co-γ ray irradiation of 100,150 and 200 Gy. The biological effects of two treatments on yield traits and quality of M6 generation were compared under the same planting conditions. The results indicated that compared with control, 4×l016 and 6 ×l0l6N+ ·cm-2 increased pods per plant(P <0. 05) and yield(P <0. 01 )of Xindadou 3 significantly;8 × 1016 ,6 × 1016and 100 Gy60Co-γ irradiation decreased seeds number and weight per plant(P <0. 05) ,100-seed weight(P< 0.05)and protein content of He99-756,respectively. 100,150 and 200 Gy60Co-γ irradiation increased fat content(P<0.05)of He99-756;4×l016and 8×l016N+ ·cm-2,100 and 200 Gy60Co-γ irradiation decreased seeds weight per plant(P <0. 05) of Xindadou 8 ,4 × 1016 ,6 × 1016 N+ ·cm-2 and 200 Gy60Co-γ irradiation increased yield of Xindadou 8 significantly;nitrogen ion beam implantation and 60Co-γ irradiation had no effect on the yield,yield components and quality of Shidadou 2. Thus the objectives of mutation breeding were determined according to sensitivity of materials, mutagenic methods and doses.%分别以3种剂量的N离子束注入(4×1016,6×1016和8×1016 N+ ·cm-2)和3种剂量的60C o-γ射线辐射(100,150和200 Gy)处理4份大豆干种子,在相同种植条件下对其M6代产量性状和品质进行研究,比较2种处理方法对大豆产量性状及品质的诱变效应.结果表明:与对照相比,新大豆3号4×1016N+·cm-2离子束注入处理单株荚数显著增加,6×1016N+ ·cm-2离子束注入处理产量极显著增加;合99-756 8×1016 N+ ·cm-2

  12. Experimental study on the temperature conditions for rod and plane irradiators with 60Co source

    International Nuclear Information System (INIS)

    Stepanov, G.D.; Osipov, V.B.; Sarapkin, I.I.; Chizhikov, V.A.

    1977-01-01

    The formation of a temperature field of rod and flat 60 Co irradiators has been studied. The experiments are carried out on a gamma installation. It has been shown that for a stationary operating mode the maximum cassette temperature (when the cassette contains a 60 Co source) is 148 deg C at maximum permissible temperature of 250 deg C. When ampoules containing the sources with maximum activity (640 Ci) are loaded into cassettes they have the temperature of 184 deg C. The reciprocal screening influence of rod irradiators gives the temperature rise of 8-10 deg in each element. The irradiators under study reach a stationary thermal operating mode in 150 min after the sources are elevated to the operating position

  13. Comparison of absorbed-dose-to-water units for Co-60 and high-energy x-rays between PTB and LNE-LNHB

    International Nuclear Information System (INIS)

    Delaunay, F.; Gouriou, J.; Le Roy, M.; Ostrowsky, A.; Sommier, L.; Vermesse, D.; Kapsch, R.P.; Illemann, J.; Krauss, A.

    2012-01-01

    During the Euramet project JRP7 'External Beam Cancer Therapy', PTB and LNE-LNHB used primary standards to determine the absorbed dose to water under IMRT conditions (in small fields). PTB used a water calorimeter to determine the absorbed-dose-to-water references in 6 MV and 10 MV beams for field sizes of 10 cm * 10 cm and 3 cm * 3 cm while LNE-LNHB used graphite calorimeters in 6MV and 12MV beams for field sizes of 10 cm * 10 cm, 4 cm * 4 cm and 2 cm * 2 cm. The purpose of this study is to compare PTB and LNE-LNHB new absorbed-dose-to-water references. LNE-LNHB sent an Exradin A1SL ionization chamber traceable to its primary standard to the PTB for calibration in 60 Co and in linac beams and PTB sent a PTW 31010 ionization chamber traceable to its primary standard to LNE-LNHB for calibration in 60 Co and in linac beams. Calculated Sw,air will be used as beam quality specifier for the ionization chamber comparison at different field sizes. The standard uncertainties (k = 1) of PTB and LNE-LNHB calibration coefficients lie respectively between 0.25% ( 60 Co) and 0.40% (linac) and between 0.29% and 0.46%. PTB and LNE-LNHB absorbed-dose-to-water references developed for this project, based respectively on water calorimetry and on graphite calorimetry, agree within 1.5 standard deviations for field size of 10 cm * 10 cm down to 2 cm * 2 cm and for beams of 6 MV to 10 MV. (authors)

  14. Treatment plan quality of tri-Co-60 MR-IGRT system in comparison with that of VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Min; Park, So Yeon; Kim, Jung In [Dept. of Nuclear Engineering, Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Hak Jae; Wu, Hong Gyun [Dept. of Nuclear Engineering, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2016-04-15

    The ViewRay{sup TM} system combines a 0.35-T MR imaging system and a radiation therapy system using a total of three Co-60 sources. It can perform static intensity-modulated radiation therapy (IMRT) with multi-leaf collimators (MLCs) with leaf widths of 1.05 cm at the plane of isocenter, at source to axis distance (SAD) of 105 cm. Since the tri-Co-60 MR-IGRT system can acquire near-real-time cine sagittal MR images during treatment, automated respiratory gating can be performed based on these cine images, thus, the target margins for lung stereotactic ablative radiotherapy (SABR) could be reduced considerably by comparison with the internal tarvet volume (ITV) approach. we compared lung SABR treatment plans of the tri-Co-60 MR-IGRT system with gross tumor volume (GTV) to those of volumetric modulated arc therapy (VMAT) using TrueBeam STx™ (Varian Medical Systems, Palo Alto, CA) with ITV in this study. The plan quality of the target volume of the VMAT with ITV was better than that of the GTV-based tri-Co-60 MR-IGRT for lung SABR. No significant differences for OARs were observed between the tri-Co-60 MR-IGRT and VMAT. However, the plan quality of the tri-Co-60 MR-IGRT system was clinically acceptable. Despite the relatively poor plan quality of the tri-Co-60 MR-IGRT system, it still has the advantage of real-time monitoring of tumor motion during treatment.

  15. Beta- and gamma-decay studies of neutron-rich chromium, manganese, cobalt and nickel isotopes including the new isotopes 60Cr and 60gMn

    International Nuclear Information System (INIS)

    Bosch, U.; Schmidt-Ott, W.D.; Runte, E.; Tidemand-Petersson, P.; Koschel, P.; Meissner, F.; Kirchner, R.; Klepper, O.; Roeckl, E.; Rykaczewski, K.; Schardt, D.

    1987-10-01

    A 36 mg/cm 2 thick nat W target was irradiated with 11.5 MeV/u 76 Ge of 15 to 20 particle + nA beam intensity. On-line mass-separated samples of projectile-like neutron-rich products from multi-nucleon transfer-reactions were investigated in the region of mass 58-69 by β- and γ-ray spectroscopy. The new isotope 60 Cr was identified with a half-life of 0.57(6) s and for the 60 Mn ground-state a half-life value of 51(6) s was obtained. Decay schemes were constructed for 58 Cr, 58 Mn (t 1/2 = 3 s), 65,66,67 Co and 69 Ni. One new γ-ray was found in the decay of 59 Cr. The Q β -value of 66 Co was measured yielding 9.7(5) MeV. The comparison of the measured new β-half-life of 60 Cr with the most recent predictions gave again an enhancement of the experimental value. (orig.)

  16. 60Co gamma irradiation effects on the the capacitance and conductance characteristics of Au/PMI/n-Si Schottky diodes

    Science.gov (United States)

    Tuğluoğlu, N.; Karadeniz, S.; Yüksel, Ö. F.; Şafak, H.; Kuş, M.

    2015-08-01

    In this work, the perylene-monoimide/n-Si (100) Schottky structures have been fabricated by spin coating process. We have studied the capacitance-voltage ( C- V) and conductance-voltage ( G- V) characteristics of the Au/perylene-monoimide/n-Si diodes at 500 kHz before and after 60Co γ-ray irradiation. The effects of 60Co γ -ray irradiation on the electrical characteristics of a perylene-monoimide/n-Si Schottky diode have been investigated. A decrease both in the capacitance and conductance has been observed after 60Co γ -ray irradiation. This has been attributed to a decrease in the net ionized dopant concentration that occurred as a result of 60Co γ-ray irradiation. Some contact parameters such as barrier height (Φ B ) interface state density ( N ss ) and series resistance ( R s ) have been calculated from the C- V and G- V characteristics of the diode before and after irradiation. It has been observed that the Φ B and N ss values are decreased after the applied radiation, while the R s value is increased.

  17. Toxoplasma gondii gamma irradiation using Co-60

    International Nuclear Information System (INIS)

    Serra-Freire, Nicolau Maues

    1996-01-01

    The use of nuclear power through radiation for the destruction of microorganisms which cause food deterioration, infections and toxicosis, is specifically for peaceful purposes. Toxoplasma gondii is a protozoa responsible for illnesses in humans and animals. One of the most common ways of transmission is through raw or poorly cooked meat. There is little information on the resistance of T. gondii to radiation. The objective of this research is to determine the Minimum Lethal Dose (MLD) of gamma radiation for those microorganisms. Suspensions of T. gondii containing approximately one million taquizoites/ml were irradiated with doses between up 0,01 up to 0,15 kGy (Kilogray) and inoculated to mice. The surviving T. gondii were re-irradiated with 0,01 up to 0,16 kGy. The irradiated protozoa were totally destroyed with a 0,15 kGy dose (MLD). Taquizoites issued from live protozoa of 0,14 kGy also were completely destroyed with dose of 0,15 kGy. No increase in resistance was observed regarding the non irradiated protozoa. (author)

  18. Decoloration Kinetics of Waste Cooking Oil by 60Co γ-ray/H2O2

    Science.gov (United States)

    Xiang, Yulin; Xiang, Yuxiu; Wang, Lipeng

    2016-03-01

    In order to decolorize, waste cooking oil, a dark red close to black solution from homes and restaurants, was subjected to 60Co γ-ray/H2O2 treatment. By virtue of UV/Vis spectrophotometric method, the influence of Gamma irradiation to decoloration kinetics and rate constants of the waste cooking oil in the presence of H2O2 was researched. In addition, the influence of different factors such as H2O2 concentration and irradiation dose on the decoloration rate of waste cooking oil was investigated. Results indicated that the decoloration kinetics of waste cooking oil conformed to the first-order reaction. The decoloration rate increased with the increase of irradiation dose and H2O2 concentration. Saponification analysis and sensory evaluation showed that the sample by 60Co γ-ray/H2O2 treatment presented better saponification performance and sensory score. Furthermore, according to cost estimate, the cost of the 60Co γ-ray/H2O2 was lower and more feasible than the H2O2 alone for decoloration of waste cooking oil.

  19. Measurements of {sup 60}Co in spoons activated by neutrons during the JCO criticality accident at Tokai-mura in 1999

    Energy Technology Data Exchange (ETDEWEB)

    Gasparro, J.; Hult, M. E-mail: mikael.hult@irmm.jrc.be; Komura, K.; Arnold, D.; Holmes, L.; Johnston, P.N.; Laubenstein, M.; Neumaier, S.; Reyss, J.-L.; Schillebeeckx, P.; Tagziria, H.; Van Britsom, G.; Vasselli, R

    2004-07-01

    Neutron activated items from the vicinity of the place where the JCO criticality accident occurred have been used to determine the fluence of neutrons around the facility and in nearby residential areas. By using underground laboratories for measuring the activation products, it is possible to extend the study to also cover radionuclides with very low activities from long-lived radionuclides. The present study describes {gamma}-ray spectrometry measurements undertaken in a range of underground laboratories for the purpose of measuring {sup 60}Co more than 2 years after the criticality event. The measurements show that neutron fluence determined from {sup 60}Co activity is in agreement with previous measurements using the short-lived radionuclides {sup 51}Cr and {sup 59}Fe. Limits on contamination of the samples with {sup 60}Co are evaluated and shown to not greatly affect the utility of neutron fluence determinations using {sup 60}Co activation.

  20. Study on dose distribution of therapeutic proton beams with prompt gamma measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. W. [National Cancer Center, Seoul (Korea, Republic of); Min, C. H.; Kim, C. H.; Kim, D. K.; Yoon, M. Y. [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2007-03-15

    The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization chamber at three different energies of 100, 150, 200 MeV's. The two distributions were well correlated within 1-2 mm. The effect of high-energy neutron appeared as blurred distribution near the distal dose falloff at the energy of 200 MeV. We then tested the PGS shielding design by adding additional layer of paraffin plates outside of the PGS, and found that fast neutrons significantly affect the background level. But the location of the dose fall-off was nearly coincident. The analysis of gamma energy spectrum showed that cut-off energy in gamma counting can be adjusted to enhance the signal to noise ratio. Further the ATOM phantom, which has similar tissue structure to human, was used to investigate the gamma distribution for the case of inhomogeneous matter. The location of dose falloff region was found to be well defined as for water phantom. Next an actual therapy beam, which was produced by the double scattering method, was used, for which the dose falloff by the gamma distribution was completely wiped out by background neutrons. It is not

  1. A dosimetric comparison of fan-beam intensity modulated radiotherapy with gamma knife stereotactic radiosurgery for treating intermediate intracranial lesions

    International Nuclear Information System (INIS)

    Ma Lijun; Xia Ping; Verhey, Lynn J.; Boyer, Arthur L.

    1999-01-01

    Purpose: To compare and evaluate treatment plans for the fan-beam intensity modulated radiotherapy and the Gamma Knife radiosurgery for treating medium-size intracranial lesions (range 4-25 cm 3 ). Methods and Materials: Treatment plans were developed for the Leksell Gamma Knife and a fan-beam inverse treatment planning system for intensity modulated radiotherapy. Treatment plan comparisons were carried out using dose-volume histogram (DVH), tissue-volume ratio (TVR), and maximum dose to the prescription dose (MDPD) ratio. The study was carried out for both simulated targets and clinical targets with irregular shapes and at different locations. Results: The MDPD ratio was significantly greater for the Gamma Knife plans than for the fan-beam IMRT plans. The Gamma Knife plans produced equivalent TVR values to the fan-beam IMRT plans. Based on the DVH comparison, the fan-beam IMRT delivered significantly more dose to the normal brain tissue than the Gamma Knife. The results of the comparison were found to be insensitive to the target locations. Conclusion: The Gamma Knife is better than the fan-beam IMRT in sparing normal brain tissue while producing equivalent tumor dose conformity for treating medium-size intracranial lesions. However, the target dose homogeneity is significantly better for the fan-beam IMRT than for the Gamma Knife

  2. Acoustic Split-Beam Echosounder Data (EK60)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Southeast Fisheries Science Center Mississippi Laboratories collects data using Simrad EK60 scientific split-beam acoustic echosounders during resource...

  3. Muon Beam Studies in the H4 beam line and the Gamma Irradiation Facility (GIF++)

    CERN Document Server

    Margraf, Rachel; CERN. Geneva. ATS Department

    2018-01-01

    In this note, we present detailed simulation results for the trajectory of a muon beam, traversing beam zones PPE-134 and PPE-154, produced by a 150 GeV positive hadron beam incident on collimators 9 & 10 in the H4 beam line when these collimators are placed off-beam axis to stop all hadrons and electrons. Using G4Beamline, a GEANT-4 based Monte-Carlo program, the trajectory of the muon beam has been studied for several field strengths of the GOLIATH magnet, as well as for different polarities. The position of the beam at the Gamma Irradiation Facility (GIF++), located downstream the PPE-144 area, is also presented. In addition, two configurations of the two XTDV’s present in the line (XTDV.022.520 and XTDV.022.610) have been studied, with the purpose to simulate the pion contamination of the beam both in PPE134 and GIF++.

  4. Electron-beam induced deposition and autocatalytic decomposition of Co(CO3NO

    Directory of Open Access Journals (Sweden)

    Florian Vollnhals

    2014-07-01

    Full Text Available The autocatalytic growth of arbitrarily shaped nanostructures fabricated by electron beam-induced deposition (EBID and electron beam-induced surface activation (EBISA is studied for two precursors: iron pentacarbonyl, Fe(CO5, and cobalt tricarbonyl nitrosyl, Co(CO3NO. Different deposits are prepared on silicon nitride membranes and silicon wafers under ultrahigh vacuum conditions, and are studied by scanning electron microscopy (SEM and scanning transmission X-ray microscopy (STXM, including near edge X-ray absorption fine structure (NEXAFS spectroscopy. It has previously been shown that Fe(CO5 decomposes autocatalytically on Fe seed layers (EBID and on certain electron beam-activated surfaces, yielding high purity, polycrystalline Fe nanostructures. In this contribution, we investigate the growth of structures from Co(CO3NO and compare it to results obtained from Fe(CO5. Co(CO3NO exhibits autocatalytic growth on Co-containing seed layers prepared by EBID using the same precursor. The growth yields granular, oxygen-, carbon- and nitrogen-containing deposits. In contrast to Fe(CO5 no decomposition on electron beam-activated surfaces is observed. In addition, we show that the autocatalytic growth of nanostructures from Co(CO3NO can also be initiated by an Fe seed layer, which presents a novel approach to the fabrication of layered nanostructures.

  5. Ion beam dump for JT-60 NBI

    International Nuclear Information System (INIS)

    Kuriyama, Masaaki; Horiike, Hiroshi; Matsuda, Shinzaburo; Morita, Hiroaki; Shibanuma, Kiyoshi

    1981-10-01

    The design of the active cooling type ion beam dump for JT-60 NBI which receives the total beam power of 5.6 MW for 10 sec continuously is described. It is composed of array of many finned tubes which is made of oxygen free copper with 0.2% silver content. The safety margin against thermal and mechanical troubles is estimated by the heat transfer and the thermal stress calculation. (author)

  6. Immune response against antigens irradiated with 60Co gamma-rays

    International Nuclear Information System (INIS)

    Baptista, J.A.; Spencer, P.J.; Oliveira, J.E.; Casare, M.S.; Nascimento, N.

    2006-01-01

    In the present work, we investigated the immunological behavior of bothropstoxin-1, a K49 phospholipase from Bothrops jararacussu, and of ovalbumin before and after irradiation with 60 Co γ-rays. Isogenic mice were immunized with either native or irradiated proteins. The circulating antibodies were isotyped and titrated by ELISA. Results indicate that irradiated proteins were immunogenic and the antibodies elicited by them were able to recognize the native proteins in ELISA. Data also indicate that the irradiated protein induced higher titers of IgG2a and IgG2b, suggesting that Th1 cells were predominantly involved in the immune response. Structural modifications of the proteins were investigated by SDSPAGE, mass spectrometry and size exclusion chromatography. According to our data, irradiation promoted structural modifications on both proteins, characterized by higher molecular weight forms (aggregates and oligomers). When analyzed by mass spectrometry, the irradiated bothropstoxin appeared in several oxidized forms. These results indicate that irradiation of toxic proteins can promote significant modifications in their structures, but still retain many of the original antigenic and immunological properties of native form. (author)

  7. An experimental and Monte Carlo investigation of the energy dependence of alanine/EPR dosimetry: I. Clinical x-ray beams

    International Nuclear Information System (INIS)

    Zeng, G G; McEwen, M R; Rogers, D W O; Klassen, N V

    2004-01-01

    The energy dependence of alanine/EPR dosimetry, in terms of absorbed dose-to-water for clinical 6, 10, 25 MV x-rays and 60 Co rays was investigated by measurements and Monte Carlo (MC) calculations. The dose rates were traceable to the NRC primary standard for absorbed dose, a sealed water calorimetry. The electron paramagnetic resonance (EPR) spectra of irradiated pellets were measured using a Bruker EMX 081 EPR spectrometer. The DOSRZnrc Monte Carlo code of the EGSnrc system was used to simulate the experimental conditions with BEAM code calculated input spectra of x-rays and γ-rays. Within the experimental uncertainty of 0.5%, the alanine EPR response to absorbed dose-to-water for x-rays was not dependent on beam quality from 6 MV to 25 MV, but on average, it was about 0.6% lower than its response to 60 Co gamma rays. Combining experimental data with Monte Carlo calculations, it is found that the alanine/EPR response per unit absorbed dose-to-alanine is the same for clinical x-rays and 60 Co gamma rays within the uncertainty of 0.6%. Monte Carlo simulations showed that neither the presence of PMMA holder nor varying the dosimeter thickness between 1 mm and 5 mm has significant effect on the energy dependence of alanine/EPR dosimetry within the calculation uncertainty of 0.3%

  8. Economics of gamma processing in cobalt-60 irradiation facilities

    International Nuclear Information System (INIS)

    Gay, H. G.; Kotler, J. G.

    1985-01-01

    Gamma processing by cobalt-60 is well established. However, since irradiation of food is relatively new from the commercial point of view, it is important to assess costs of gamma irradiation in the context of food processing. Five different types of AECL-RCC irradiation equipment are examined in terms of their throughputs, and capital and operating costs. Using these figures, costs of irradiation of nine types of food products are presented. In general, these represent about 2-10% of the wholesale cost of these products

  9. Detection of mixed-range proton pencil beams with a prompt gamma slit camera

    International Nuclear Information System (INIS)

    Priegnitz, M; Helmbrecht, S; Fiedler, F; Janssens, G; Smeets, J; Vander Stappen, F; Perali, I; Sterpin, E

    2016-01-01

    With increasing availability of proton and particle therapy centers for tumor treatment, the need for in vivo range verification methods comes more into the focus. Imaging of prompt gamma rays emitted during the treatment is one of the possibilities currently under investigation. A knife-edge shaped slit camera was recently proposed for this task and measurements proved the feasibility of range deviation detection in homogeneous and inhomogeneous targets. In the present paper, we concentrate on laterally inhomogeneous materials, which lead to range mixing situations when crossed by one pencil beam: different sections of the beam have different ranges. We chose exemplative cases from clinical irradiation and assembled idealized tissue equivalent targets. One-dimensional emission profiles were obtained by measuring the prompt gamma emission with the slit camera. It could be shown that the resulting range deviations can be detected by evaluation of the measured data with a previously developed range deviation detection algorithm. The retrieved value, however, strongly depends on the target composition, and is not necessarily in direct relation to the ranges of both parts of the beam. By combining the range deviation detection with an analysis of the slope of the distal edge of the measured prompt gamma profile, the origin of the detected range deviation, i.e. the mixed range of the beam, is also identified. It could be demonstrated that range mixed prompt gamma profiles exhibit less steep distal slopes than profiles from beams traversing laterally homogeneous material. For future application of the slit camera to patient irradiation with double scattered proton beams, situations similar to the range mixing cases are present and results could possibly apply. (paper)

  10. SU-E-T-623: Polarity Effects for Small Volume Ionization Chambers in Cobalt-60 Beams

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Y; Bhatnagar, J; Huq, M Saiful [Department of Radiation Oncology, University of Pittsburgh Cancer Institute and UPMC Cancer Center, Pittsburgh, PA (United States)

    2015-06-15

    Purpose: To investigate the polarity effects for small volume ionization chambers in {sup 60}Co gamma-ray beams using the Leksell Gamma Knife Perfexion. Methods: Measurements were made for 7 small volume ionization chambers (a PTW 31016, an Exradin A14, 2 Capintec PR0-5P, and 3 Exradin A16) using a PTW UNIDOSwebline Universal Dosemeter and an ELEKTA solid water phantom with proper inserts. For each ion chamber, the temperature/pressure corrected electric charge readings were obtained for 16 voltage values (±50V, ±100V, ±200V, ±300V, ±400V, ±500V, ±600V, ±700V). For each voltage, a five-minute leakage charge reading and a series of 2-minute readings were continuously taken during irradiation until 5 stable signals (less than 0.05% variation) were obtained. The average of the 5 reading was then used for the calculation of the polarity corrections at the voltage and for generating the saturation curves. Results: The polarity effects are more pronounced at high or low voltages than at the medium voltages for all chambers studied. The voltage dependence of the 3 Exradin A16 chambers is similar in shape. The polarity corrections for the Exradin A16 chambers changes rapidly from about 1 at 500V to about 0.98 at 700V. The polarity corrections for the 7 ion chambers at 300V are in the range from 0.9925 (for the PTW31016) to 1.0035 (for an Exradin A16). Conclusion: The polarity corrections for certain micro-chambers are large even at normal operating voltage.

  11. Prototype ion source for JT-60 neutral beam injectors

    International Nuclear Information System (INIS)

    Akiba, M.

    1981-01-01

    A prototype ion source for JT-60 neutral beam injectors has been fabricated and tested. Here, we review the construction of the prototype ion source and report the experimental results about the source characteristics that has been obtained at this time. The prototype ion source is now installed at the prototype unit of JT-60 neutral beam injection units and the demonstration of the performances of the ion source and the prototype unit has just started

  12. Gamma-ray-burst beaming and gravitational-wave observations.

    Science.gov (United States)

    Chen, Hsin-Yu; Holz, Daniel E

    2013-11-01

    Using the observed rate of short-duration gamma-ray bursts (GRBs) it is possible to make predictions for the detectable rate of compact binary coalescences in gravitational-wave detectors. We show that the nondetection of mergers in the existing LIGO/Virgo data constrains the beaming angles and progenitor masses of gamma-ray bursts, although these limits are fully consistent with existing expectations. We make predictions for the rate of events in future networks of gravitational-wave observatories, finding that the first detection of a neutron-star-neutron-star binary coalescence associated with the progenitors of short GRBs is likely to happen within the first 16 months of observation, even in the case of only two observatories (e.g., LIGO-Hanford and LIGO-Livingston) operating at intermediate sensitivities (e.g., advanced LIGO design sensitivity, but without signal recycling mirrors), and assuming a conservative distribution of beaming angles (e.g., all GRBs beamed within θ(j) = 30°). Less conservative assumptions reduce the waiting time until first detection to a period of weeks to months, with an event detection rate of >/~10/yr. Alternatively, the compact binary coalescence model of short GRBs can be ruled out if a binary is not seen within the first two years of operation of a LIGO-Hanford, LIGO-Livingston, and Virgo network at advanced design sensitivity. We also demonstrate that the gravitational wave detection rate of GRB triggered sources (i.e., those seen first in gamma rays) is lower than the rate of untriggered events (i.e., those seen only in gravitational waves) if θ(j)≲30°, independent of the noise curve, network configuration, and observed GRB rate. The first detection in gravitational waves of a binary GRB progenitor is therefore unlikely to be associated with the observation of a GRB.

  13. INFLUENCE OF INCUBATION TIME, GAMMA RAYS AND ELECTRON BEAM ON RADIATION RESISTANCE OF SOME SELECTED PATHOGENS

    International Nuclear Information System (INIS)

    EL-HIFNAWI, H.N.; EL-TABLAWY, S.Y.

    2009-01-01

    The effect of different growth phases on the radiation resistance, antibiotic susceptibility and pathogenicity of certain selected pathogens (Escherichia coli, Candida albicans and Staphylococcus aureus) was studied in mice. The obtained results showed that Escherichia coli was slightly more resistant to gamma radiation in 18 h than 24 h or 48 h but it was relatively more resistant to electron beam in 24 h and 48 h than 18 h. Candida albicans showed radiation resistance nearly the same in all incubation times in the case of gamma radiation while for electron beam, its radiation resistance was slightly more in 24 h and 48 h than in 18 h. On the other hand, Staphylococcus aureus recorded much more resistance to gamma radiation in the 48 h than in 24 h or 18 h whereas in the case of electron beam, it was slightly more resistant in 18 h than in 24 h and 48 h.The antibiotic susceptibility of Escherichia coli reported that the exposure to gamma radiation at 3 kGy and electron beam at 6 kGy increase the susceptibility to the nalidixic acid and nitrofurantoin. When Candida albicans was exposed to 3 kGy gamma radiation and 6 kGy electron beam, the same sensitivity to nystatin was observed in comparison with the unexposed one while the sensitivity of Staphylococcus aureus to some antibiotics (amoxicillin, nitrofurantoin and tetracycline) was decreased after exposure to gamma radiation at 0.75 and 2 kGy and electron beam at 6 kGy, but for other antibiotics (trimethoprim/ sulfamethoxazole), the sensitivity was increased at 6 kGy electron beam.The lethality percent recorded after the oral ingestion of the mice with the unexposed Escherichia coli and Candida albicans were 25% and 100%, respectively, and for 6 kGy exposure to electron beam was 0% . The cotaneous disease and abscesses caused by the intradermal injection of the mice with unexposed Staphylococcus aureus was 75% and for 6 kGy exposure to electron beam was 25%.

  14. Alanine/epr pellet dosimeter using poly(vinyl butyral-co-vinyl alcohol-co-vinyl acetate) copolymer as a binder for radiation dosimetry

    International Nuclear Information System (INIS)

    Beshir, W.B.; Ezz El-Din, H.M.; Abdel-fatth, A.A.; Ebraheem, S.

    2005-01-01

    A new alanine pellet dosimeter was developed for gamma and electron beam radiation dosimetry. Alanine powder was mixed with a new binding material, poly(vinyl butyral-co-vinyl alcohol-co-vinyl acetate) copolymer. Pellets were prepared by pressing fine powder alanine with 60% copolymer binder by using hydraulic press and a specially designed pressing die. The radiation-formed stable free radicals were analysed by using electron paramagnetic resonance (EPR) spectroscopy. The useful dose range of these pellets was found to ranges from 1 to 80 kGy. The stability of the radiation- induced response was also studied

  15. Electrophysical properties of In P crystals, irradiated with CO-60 gamma quanta

    International Nuclear Information System (INIS)

    Aliyev, M.I.; Guseynova, M.A.; Aliyev, I.M.; Ragimov, S.S.

    2005-01-01

    Full text : n-InP monocrystals were investigated before and after gamma irradiation having a doze about 10 and also within temperature interval from 77 to 320 K. On χ(T) and σ(T) dependences it is revealed that during gamma irradiation p-type antistructural defects are generated in n-InP crystals. It gives an opportunity of receiving of not alloyed semiinsulating indium fosfide [ru

  16. High-energy gamma-ray beams from Compton-backscattered laser light

    Energy Technology Data Exchange (ETDEWEB)

    Sandorfi, A.M.; LeVine, M.J.; Thorn, C.E.; Giordano, G.; Matone, G.

    1983-01-01

    Collisions of light photons with relativistic electrons have previously been used to produce polarized ..gamma..-ray beams with modest (-10%) resolution but relatively low intensity. In contrast, the LEGS project (Laser + Electron Gamma Source) at Brookhaven will produce a very high flux (>2 x 10/sup 7/ s/sup -1/) of background-free polarized ..gamma.. rays whose energy will be determined to a high accuracy (..delta..E = 2.3 MeV). Initially, 300(420)-MeV ..gamma.. rays will be produced by backscattering uv light from the new 2.5(3.0)-GeV X-ray storage ring of the National Synchrotron Light Source (NSLS). The LEGS facility will operate as one of many passive users of the NSLS. In a later stage of the project, a Free Electron Laser is expectred to extend the ..gamma..-ray energy up to 700 MeV.

  17. Preliminary study about frequencies of unstable chromosome alterations induced by gamma beam and neutron-gamma mixed field

    International Nuclear Information System (INIS)

    Mendes, Mariana E.; Souza, Priscilla L.G.; Brandao, Jose Odinilson de C.; Santos, Joelan A.L.; Vilela, Eudice C.; Lima, Fabiana F.; Calixto, Merilane S.; Santos, Neide

    2011-01-01

    The estimate on approximate dose in exposed individual can be made through conventional cytogenetic analysis of dicentric, this technique has been used to support physical dosimetry. It is important to estimate the absorbed dose in case of accidents with the aim of developing an appropriate treatment and biological dosimetry can be very useful in case where the dosimetry is unavailable. Exposure to gamma and neutron radiation leads to the same biological effects such as chromosomal alterations and cancer. However, neutrons cause more genetic damage, such as mutation or more structural damage, such as chromosome alterations. The aim of research is to compare frequencies of unstable chromosome alterations induced by a gamma beam with those from neutron-gamma mixed field. Two blood samples were obtained from one healthy donor and irradiated at different sources. The first sample was exposed to mixed field neutron-gamma sources 241 AmBe at the Neutron Calibration Laboratory (NCL - CRCN/NE - PE - Brazil) and the second one was exposed to 137 Cs gamma rays at 137 Cs Laboratory (CRCN/NE - PE - Brazil), both exposures resulting in an absorbed dose of 0.66Gy. Mitotic metaphase cells were obtained by lymphocyte culture for chromosomal analysis and slides were stained with Giemsa 5%. These preliminary results showed a similarity in associated dicentrics frequency per cell (0.041 and 0.048) after 137 Cs and 241 AmBe sources irradiations, respectively. However, it was not observed centric rings frequency per cell (0.0 and 0.027). This study will be continue to verify the frequencies of unstable chromosome alterations induced by only gamma beam and neutron-gamma mixed field. (author)

  18. Preliminary study about frequencies of unstable chromosome alterations induced by gamma beam and neutron-gamma mixed field

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, Mariana E.; Souza, Priscilla L.G.; Brandao, Jose Odinilson de C.; Santos, Joelan A.L.; Vilela, Eudice C.; Lima, Fabiana F. [Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Calixto, Merilane S.; Santos, Neide [Universidade Federal de Pernanmbuco (CCB/UFPE), Recife, PE (Brazil). Centro de Ciencias Biologicas. Dept. de Genetica

    2011-07-01

    The estimate on approximate dose in exposed individual can be made through conventional cytogenetic analysis of dicentric, this technique has been used to support physical dosimetry. It is important to estimate the absorbed dose in case of accidents with the aim of developing an appropriate treatment and biological dosimetry can be very useful in case where the dosimetry is unavailable. Exposure to gamma and neutron radiation leads to the same biological effects such as chromosomal alterations and cancer. However, neutrons cause more genetic damage, such as mutation or more structural damage, such as chromosome alterations. The aim of research is to compare frequencies of unstable chromosome alterations induced by a gamma beam with those from neutron-gamma mixed field. Two blood samples were obtained from one healthy donor and irradiated at different sources. The first sample was exposed to mixed field neutron-gamma sources {sup 241}AmBe at the Neutron Calibration Laboratory (NCL - CRCN/NE - PE - Brazil) and the second one was exposed to {sup 137}Cs gamma rays at {sup 137}Cs Laboratory (CRCN/NE - PE - Brazil), both exposures resulting in an absorbed dose of 0.66Gy. Mitotic metaphase cells were obtained by lymphocyte culture for chromosomal analysis and slides were stained with Giemsa 5%. These preliminary results showed a similarity in associated dicentrics frequency per cell (0.041 and 0.048) after {sup 137}Cs and {sup 241}AmBe sources irradiations, respectively. However, it was not observed centric rings frequency per cell (0.0 and 0.027). This study will be continue to verify the frequencies of unstable chromosome alterations induced by only gamma beam and neutron-gamma mixed field. (author)

  19. Performance analysis of a threshold-based parallel multiple beam selection scheme for WDM-based systems for Gamma-Gamma distributions

    KAUST Repository

    Nam, Sung Sik

    2017-03-02

    In this paper, we statistically analyze the performance of a threshold-based parallel multiple beam selection scheme (TPMBS) for Free-space optical (FSO) based system with wavelength division multiplexing (WDM) in cases where a pointing error has occurred for practical consideration over independent identically distributed (i.i.d.) Gamma-Gamma fading conditions. Specifically, we statistically analyze the characteristics in operation under conventional heterodyne detection (HD) scheme for both adaptive modulation (AM) case in addition to non-AM case (i.e., coherentnon-coherent binary modulation). Then, based on the statistically derived results, we evaluate the outage probability (CDF) of a selected beam, the average spectral efficiency (ASE), the average number of selected beams (ANSB), and the average bit error rate (BER). Some selected results shows that we can obtain the higher spectral efficiency and simultaneously reduce the potential increasing of the complexity of implementation caused by applying the selection based beam selection scheme without a considerable performance loss.

  20. Interaction of co-insult treatments wth cadmium chloride and gamma irradiation on lethality and blood indices

    International Nuclear Information System (INIS)

    Morgan, R.M.

    1981-01-01

    The main objectives of this study were (1) to gain insight into sensitivities of vital organs systems after treatments with cadmium chloride (CdCl 2 ), gamma ( 60 Co) radiation, and combined CdCl 2 -gamma radiation; (2) to determine physiological and cellular/molecular changes after these same treatments; and (3) to develop a summary of biochemical/hematological indicators for each insult individually, as well as for the co-insult treatment. Three lethality studies, Acute CdCl 2 , Chronic CdCl 2 , and Acute Radiation, wwere used to determine sublethal doses for the fourth study (Co-insult), which utilized various combinations of CdCl 2 and gamma radiation and from which the hematological and biochemical data were derived. Radiation groups exhibited statistically significant decreases in the total number of leukocytes, lymphocytes, and polyneutrophils. Significant increases were seen in serum iron, lactate dehydrogenase (LDH), alkaline phosphatase, and triglycerides. Cadmium groups had increased total numbers of leukocytes, polyneutrophils, and serum glutamic oxaloacetate transminase (SGOT). Decreases were seen in lymphocytes, hemoglobin, hematocrit, total red blood cell counts, and total protein. When co-insult treatments were used, significant decreases were seen in the total number of leukocytes, polyneutrophils, lymphocytes, hemoglobin, total red blood cells, and serum iron

  1. Hippophae leaf extract (SBL-1) countered radiation induced dysbiosis in jejunum of total body 60Cobalt gamma - irradiated mice

    International Nuclear Information System (INIS)

    Beniwal, C.S.; Madhu Bala

    2014-01-01

    Single dose of SBL-1 administered at the rate 30 mg/kg body weight (b.w.) 30 min prior to whole body 60 Co-gamma-irradiation at lethal dose (10 Gy), rendered >90% survival in comparison to zero survival in the non-SBL-1 treated 60 Co-gamma-irradiated (10 Gy) mice population (J Herbs Spices Med Plants, 2009; 15(2): 203-215). Present study investigated the effect of SBL-1 on jejunal microbiota in lethally irradiated mice. Study was performed with inbred Swiss albino Strain 'A' male mice (age 9 weeks) weighing 28±2 g. The animals were maintained under controlled environment at 26±2℃; 12 h light/dark cycle and offered standard animal food (Golden feed, Delhi) as well as tap water ad libitum. Metagenomic DNA was extracted, purified and quantified from jejunum of the mice. Universal primers (27f and 1492r) were used to amplify the 16S rRNA DNA from the metagenomic DNA. Amplicons were sequenced, vector contamination and chimeras were removed. The sequences (GenBank Accession No: KF681283 to KF681351) were taxonomically classified by using Sequence Match program, Ribosomal Database Project as well as by nucleotide-BLAST (E-value: 10, database: 16S rRNA gene sequences, Bacteria and Archea). Phylogenetic Tree was prepared using MEGA 5.2 package, using maximum likelihood algorithm after sequence alignment by MUSCLE. Thermus aquaticus was used as out-group to construct rooted tree. Branch stability was assessed by bootstrap analysis. Untreated animals and the animals treated with SBL-1 had 100% Lactobacillus; 60 Co gamma-irradiated animals had 55% Cohaesibacter (Alphaproteobacteria); 27% Mycoplasma (Tenericutes) and only 18% Lactobacillus; animals treated with SBL-1 prior to irradiation had 89% Lactobacillus and 11% Clostridium. This study demonstrated that treatment with SBL-1 at radioprotective doses before total body irradiation with lethal dose (10 Gy) countered the jejunal dysbiosis. (author)

  2. Quarantine treatment in eggs of Stenoma catenifer Walsingham (Lepidoptera: Elachistidae), with gamma radiation of Cobalt-60

    International Nuclear Information System (INIS)

    Silva, L.K.F.; Arthur, V.; Nava, D.E.; Parra, J.R.P.

    2006-01-01

    The objective of this work has been to determine the lethal dose of gamma radiation of Cobalt-60 for the Stenoma catenifer eggs. For the irradiation of the eggs an irradiador Gammacell-220 (CO60) was utilized, (Rate dose: 1.054 kGY/h). The doses were: 0, 25, 50, 75, 100, 125 and 150 Gy, 90 eggs/dose (six repetitions). The number of caterpillars emerged was evaluated, and the survivors growed in seeds of avocado. The adults obtained were coupled with normal insects, growed in boxes with double face paper containing the food (10% honey) and a fruit of avocado. The experimental design was totally random, being the data submitted to the analysis of the varianza and the averages compared by the test of Tukey (P=5%). The emergence of caterpillars from the treated eggs with dose of 0, 25 and 50 Gy was verified. The dose of 50 Gy caused deformation in the caterpillars emerged. The effect of the gamma radiation in the viability of the eggs was proportional to the dose increase. The adults from the eggs dealt with 25 Gy presented non viabilty of 92,85 and 100% for male and female, respectively. A radiation gamma of 75 Gy is recommended for treatment quarantine for avocado fruits infested with of S. catenifer eggs

  3. Damage to plasmid DNA produced by 60Co-gamma radiation and subsequent repair processes in E. coli with and without SOS induction

    International Nuclear Information System (INIS)

    Bien, M.

    1986-01-01

    This study was carried out to provide information on the question as to whether radiation-induced separation of double-stranded DNA in E. coli is followed by repair processes leading to the formation of replicable material. For the detection of those double-strand breaks, E. coli was first transformed using enzymatically linearised dBR 322-DNA. This served as a reference standard to compare the transformations using radiated DNA. DNA was either exposed to increasing doses of 60 Co-gamma radiation or separated into one oc-fraction and one lin-fraction following exposure to 30 Gy. The DNA samples thus obtained were then used to transform three different strains of E. coli (wild strain, SFX, SFXrecA - ). In order to improve the repair yield, the cells were additionally SOS-induced using ultraviolet radiation. The mutation rates were a measure of the number of errors occurring during the various repair processes. Restriction analysis was carried out to characterise the resulting mutants in greater detail. (orig./MG) [de

  4. Sorption of {sup 60} Co on inorganic solids; Sorcion de {sup 60} Co en solidos inorganicos

    Energy Technology Data Exchange (ETDEWEB)

    Granados C, F.; Bulbulian G, S. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Mardel V, B. [UAM-I, 09340 Mexico D.F. (Mexico)

    2003-07-01

    The behavior of sorption of the {sup 60} Co in aqueous solution under static conditions to different values of pH of the aqueous solution (1, 3, 5, 7, and 10) on MgO, MnO{sub 2}, SnO, TiO{sub 2}, activated carbon and calcinate hydrotalcite was investigated. It was found that the best sorbents of the {sup 60} Co was the MnO{sub 2}, activated carbon and TiO{sub 2} whose sorption was incremented when increasing the pH value of the aqueous solutions, in the one case of the hydrated oxides, the {sup 60} Co interacted with the electrically charged surface of the sorbents that depends on the pH of the solution and of the point of zero charge (zpc) of the sorbent. (Author)

  5. Effects of gamma and electron beam irradiation on the survival of pathogens inoculated into sliced and pizza cheeses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun-Joo [Department of Food Science and Technology, Chung-Ang University, Ansung, Gyunggi-do 456-756 (Korea, Republic of); Ham, Jun-Sang [Animal Products Processing Division, National Livestock Research Institute, RDA, Suwon 441-706 (Korea, Republic of); Lee, Ju-Woon [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Kim, Keehyuk [Department of Culinary Nutrition, Woosong University, Daejeon 300-718 (Korea, Republic of); Ha, Sang-Do [Department of Food Science and Technology, Chung-Ang University, Ansung, Gyunggi-do 456-756 (Korea, Republic of); Jo, Cheorun, E-mail: cheorun@cnu.ac.k [Department of Animal Science and Biotechnology, Chungnam National University, Daejeon 305-764 (Korea, Republic of)

    2010-06-15

    The objective of this study was to identify the efficacy of gamma and electron beam irradiation of the food-borne pathogens (Listeria monocytogenes and Staphylococcus aureus) in sliced and pizza cheeses commercially available in the Korean market. Total aerobic bacteria and yeast/mold in the cheeses ranged from 10{sup 2} to 10{sup 3} Log CFU/g. Irradiation of 1 kGy for sliced cheese and 3 kGy for pizza cheese were sufficient to lower the total aerobic bacteria to undetectable levels (10{sup 1} CFU/g). Pathogen inoculation test revealed that gamma irradiation was more effective than electron beam irradiation at the same absorbed dose, and the ranges of the D{sub 10} values were from 0.84 to 0.93 kGy for L. monocytogenes and from 0.60 to 0.63 kGy for S. aureus. Results suggest that a low dose irradiation can improve significantly the microbial quality and reduce the risk of contamination of sliced and pizza cheeses by the food-borne pathogens which can potentially occur during processing.

  6. Effects of gamma and electron beam irradiation on the survival of pathogens inoculated into sliced and pizza cheeses

    International Nuclear Information System (INIS)

    Kim, Hyun-Joo; Ham, Jun-Sang; Lee, Ju-Woon; Kim, Keehyuk; Ha, Sang-Do; Jo, Cheorun

    2010-01-01

    The objective of this study was to identify the efficacy of gamma and electron beam irradiation of the food-borne pathogens (Listeria monocytogenes and Staphylococcus aureus) in sliced and pizza cheeses commercially available in the Korean market. Total aerobic bacteria and yeast/mold in the cheeses ranged from 10 2 to 10 3 Log CFU/g. Irradiation of 1 kGy for sliced cheese and 3 kGy for pizza cheese were sufficient to lower the total aerobic bacteria to undetectable levels (10 1 CFU/g). Pathogen inoculation test revealed that gamma irradiation was more effective than electron beam irradiation at the same absorbed dose, and the ranges of the D 10 values were from 0.84 to 0.93 kGy for L. monocytogenes and from 0.60 to 0.63 kGy for S. aureus. Results suggest that a low dose irradiation can improve significantly the microbial quality and reduce the risk of contamination of sliced and pizza cheeses by the food-borne pathogens which can potentially occur during processing.

  7. Effects of gamma and electron beam irradiation on the survival of pathogens inoculated into sliced and pizza cheeses

    Science.gov (United States)

    Kim, Hyun-Joo; Ham, Jun-Sang; Lee, Ju-Woon; Kim, Keehyuk; Ha, Sang-Do; Jo, Cheorun

    2010-06-01

    The objective of this study was to identify the efficacy of gamma and electron beam irradiation of the food-borne pathogens ( Listeria monocytogenes and Staphylococcus aureus) in sliced and pizza cheeses commercially available in the Korean market. Total aerobic bacteria and yeast/mold in the cheeses ranged from 10 2 to 10 3 Log CFU/g. Irradiation of 1 kGy for sliced cheese and 3 kGy for pizza cheese were sufficient to lower the total aerobic bacteria to undetectable levels (10 1 CFU/g). Pathogen inoculation test revealed that gamma irradiation was more effective than electron beam irradiation at the same absorbed dose, and the ranges of the D 10 values were from 0.84 to 0.93 kGy for L. monocytogenes and from 0.60 to 0.63 kGy for S. aureus. Results suggest that a low dose irradiation can improve significantly the microbial quality and reduce the risk of contamination of sliced and pizza cheeses by the food-borne pathogens which can potentially occur during processing.

  8. Description of morphologic characters in avocado trees (Persea americana. Mill) var. Hass, submitted to gamma radiation of {sup 60} Co; Descripcion de caracteres morfologicos en arboles de aguacate (Persea americana. Mill) var. Hass, sometidos a radiacion gama de {sup 60} Co

    Energy Technology Data Exchange (ETDEWEB)

    Sandoval R, L

    2004-07-01

    It was carried out the characterization of 77 trees of avocado ''Hass'' subjected to gamma radiation of Co{sup 60}, in doses of 0, 5, 10,15, 20 and 25 Gy based on previous studies of radiosensitivity with ends of improvement located in the experimental center ''La Labor'' belonging to the foundation Salvador Sanchez Colin. CICTAMEX. S C. in Temascaltepec, Mexico. It was carried out the morphological characterization of this variety according to the nomenclature settled down by the International Office of Genetic Resources (IBPGRI), registering 27 variables for the description of the tree, 33 for description of the fruit and 14 for the characterization of the seed. Regarding the architectural characterization 10 variables were evaluated. Using gamma radiation of Co{sup 60} in the doses of 15 and 20 Gy it was detected a reduction of 22% in the portage of the tree, likewise had reduction the diameter of the trunk and of the foliage. It was found that the reduction in the behavior of the tree induces to a bigger variation of the form of the same one, in the distribution of the branches in the form of the fruit and in the form of the seed you Also detects a remarkable increment in the productivity of some hoist irradiated regarding the architecture of the tree one observes that the angle of inclination of the branches increase when being increased the radiation dose and that the longitude of the annual section of growth decreased significantly in the doses of 20 and 25 Gy. One observes a significant Increment in the I number of buds prolepticos in those hoist irradiated in the I finish mbdulo of rhythmic growth. Io that indicates a change substantial in the I inhabit of growth With the purpose of determining if the changes in morphology and architecture of the tree corresponded with the modification at level meristematico, they were carried out observations to the court microscope of having knitted apical vegetative meristematico in samples of you hoist of all the

  9. Description of morphologic characters in avocado trees (Persea americana. Mill) var. Hass, submitted to gamma radiation of {sup 60} Co; Descripcion de caracteres morfologicos en arboles de aguacate (Persea americana. Mill) var. Hass, sometidos a radiacion gama de {sup 60} Co

    Energy Technology Data Exchange (ETDEWEB)

    Sandoval R, L

    2004-07-01

    It was carried out the characterization of 77 trees of avocado ''Hass'' subjected to gamma radiation of Co{sup 60}, in doses of 0, 5, 10,15, 20 and 25 Gy based on previous studies of radiosensitivity with ends of improvement located in the experimental center ''La Labor'' belonging to the foundation Salvador Sanchez Colin. CICTAMEX. S C. in Temascaltepec, Mexico. It was carried out the morphological characterization of this variety according to the nomenclature settled down by the International Office of Genetic Resources (IBPGRI), registering 27 variables for the description of the tree, 33 for description of the fruit and 14 for the characterization of the seed. Regarding the architectural characterization 10 variables were evaluated. Using gamma radiation of Co{sup 60} in the doses of 15 and 20 Gy it was detected a reduction of 22% in the portage of the tree, likewise had reduction the diameter of the trunk and of the foliage. It was found that the reduction in the behavior of the tree induces to a bigger variation of the form of the same one, in the distribution of the branches in the form of the fruit and in the form of the seed you Also detects a remarkable increment in the productivity of some hoist irradiated regarding the architecture of the tree one observes that the angle of inclination of the branches increase when being increased the radiation dose and that the longitude of the annual section of growth decreased significantly in the doses of 20 and 25 Gy. One observes a significant Increment in the I number of buds prolepticos in those hoist irradiated in the I finish mbdulo of rhythmic growth. Io that indicates a change substantial in the I inhabit of growth With the purpose of determining if the changes in morphology and architecture of the tree corresponded with the modification at level meristematico, they were carried out observations to the court microscope of having knitted apical vegetative meristematico

  10. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy.

    Directory of Open Access Journals (Sweden)

    Luciana Tourinho Campos

    Full Text Available The use of high-dose-rate brachytherapy is currently a widespread practice worldwide. The most common isotope source is 192Ir, but 60Co is also becoming available for HDR. One of main advantages of 60Co compared to 192Ir is the economic and practical benefit because of its longer half-live, which is 5.27 years. Recently, Eckert & Ziegler BEBIG, Germany, introduced a new afterloading brachytherapy machine (MultiSource®; it has the option to use either the 60Co or 192Ir HDR source. The source for the Monte Carlo calculations is the new 60Co source (model Co0.A86, which is referred to as the new BEBIG 60Co HDR source and is a modified version of the 60Co source (model GK60M21, which is also from BEBIG.The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy to investigate the required treatment-planning parameters. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. To validate the source geometry, a few dosimetry parameters had to be calculated according to the AAPM TG-43U1 formalism. The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The spectrum to simulate 60Co was composed of two photon energies, 1.17 and 1.33 MeV. Only the gamma part of the spectrum was used; the contribution of the electrons to the dose is negligible because of the full absorption by the stainless-steel wall around the metallic 60Co. The XCOM photon cross-section library was used in subsequent simulations, and the photoelectric effect, pair

  11. The PRESPEC liquid-hydrogen target for in-beam gamma spectroscopy of exotic nuclei at GSI

    International Nuclear Information System (INIS)

    Louchart, C.; Gheller, J.M.; Chesny, Ph.; Authelet, G.; Rousse, J.Y.; Obertelli, A.; Boutachkov, P.; Pietri, S.; Ameil, F.; Audirac, L.; Corsi, A.; Dombradi, Z.; Gerl, J.; Gillibert, A.; Korten, W.; Mailleret, C.; Merchan, E.; Nociforo, C.; Pietralla, N.; Ralet, D.

    2014-01-01

    We report on a new liquid hydrogen and deuterium target dedicated to in-beam γ spectroscopy experiments in inverse kinematics at relativistic incident energies at GSI/FAIR. Target thicknesses from 10 to 80 mm can be achieved for an effective diameter of 60 mm. The target-cell and entrance window are maded of 200μm thick Mylar. The design has the advantage of being free of absorbing material at forward angles and 90°, allowing the detection of photons in a wide angular range. A commissioning experiment with a 54 Cr beam at 130 MeV/nucleon has been performed at GSI, using the Rare Isotopes INvestigation at GSI (RISING) detectors. The target has been shown to behave as expected and is ready for experiments at fragmentation Radioactive-Ion Beam Facilities. -- Highlights: • We report on a new liquid hydrogen target for gamma spectroscopy experiments at FAIR. • A commissioning experiment has been performed at GSI, using the RISING detectors. • The target behaves as expected and is ready for experiments

  12. Proceeding of the workshop on gamma-ray spectroscopy utilizing heavy-ion, photon and RI beams

    Energy Technology Data Exchange (ETDEWEB)

    Oshima, Masumi; Sugita, Michiaki; Hayakawa, Takehito [eds.

    1998-03-01

    Three time since 1992, we have held the symposia entitled `Joint Spectroscopy Experiments Utilizing JAERI Tandem-Booster Accelerator` at the Tokai Research Establishment. In the symposia, we have mainly discussed the plans of experiments to be done in this joint program. The joint program started in 1994. Several experiments have been made since and some new results have already come up. This symposium `Gamma-ray Spectroscopy utilizing heavy-ion, Photon and RI beams` was held at Tokai Research Establishment of JAERI. Because this symposium is the first occasion after the program started, the first purpose of the symposium is to present and discuss the experimental results so far obtained using the JAERI Tandem-Booster. The second purpose of the symposium is to discuss new possibilities of gamma-ray spectroscopy using new resources such as RI-beam and Photon-beam. The participants from RIKEN, Tohoku University and JAERI Neutron Science Research Center presented the future plans of experiments with RI-beam at each facility. Compared with these nuclear beams, photon beam provides a completely new tool for the {gamma}-ray spectroscopy, which is achieved by inverse Compton scattering between high-energy electron and laser beams. The 23 of the presented papers are indexed individually. (J.P.N.)

  13. Doses in sensitive organs during prostate treatment with a 60Co unit

    International Nuclear Information System (INIS)

    Vega-Carrillo, H.R.; Navarro Becerra, J.A.; Pérez Arrieta, M.L.; Pérez-Landeros, L.H.

    2014-01-01

    Using thermoluminiscent dosimeters the absorbed dose in the bladder, rectum and thyroid have been evaluated when 200 cGy was applied to the prostate. The treatment was applied with a 60 Co unit. A water phantom was built and thermoluminiscent dosimeters were located in the position where the prostate, bladder, rectum and thyroid are located. The therapeutic beam was applied in 4 irradiations at 0, 90, 180 and 270° with the prostate at the isocenter. The TLDs readouts were used to evaluate the absorbed dose in each organ. The absorbed doses were used to estimate the effective doses and the probability of developing secondary malignacies in thyroid, rectum and bladder. - Highlights: • The absorbed doses in the bladder, rectum and thyroid were measured. • Measurements were done during prostate treatment with a 60 Co unit. • TLD100s in a water phantom were used. • The effective doses were also estimated

  14. Emerging terawatt picosecond CO{sub 2} laser technology

    Energy Technology Data Exchange (ETDEWEB)

    Pogorelsky, I V [Accelerator Test Facility, Brookhaven National Lab., Upton, NY (United States)

    1998-03-01

    The first terawatt picosecond (TWps) CO{sub 2} laser is under construction at the BNL Accelerator Test Facility (ATF). TWps-CO{sub 2} lasers, having an order of magnitude longer wavelength than the well-known table-top terawatt solid state lasers, offer new opportunities for strong-field physics research. For laser wakefield accelerators (LWFA) the advantage of the new class of lasers is due to a gain of two orders of magnitude in the ponderomotive potential. The large average power of CO{sub 2} lasers is important for the generation of hard radiation through Compton back-scattering of the laser off energetic electron beams. We discuss applications of TWps-CO{sub 2} lasers for LWFA modules of a tentative electron-positron collider, for {gamma}-{gamma} (or {gamma}-lepton) colliders, for a possible `table-top` source of high-intensity x-rays and gamma rays, and the generation of polarized positron beams. (author)

  15. UNDERWATER ANALYSIS OF IRRADIATED REACTOR SLUGS FOR Co-60 AND OTHER RADIONUCLIDES AT THE SAVANNAH RIVER SITE

    International Nuclear Information System (INIS)

    CASELLA, VITO

    2004-01-01

    Co-60 was produced in the Savannah River Site (SRS) reactors in the 1970s, and the irradiated cobalt reactor slugs were stored in a reactor basin at SRS. Since the activity rates of these slugs were not accurately known, assaying was required. A sodium iodide gamma detector was placed above a specially designed air collimator assembly, so that the slug was eight to nine feet from the detector and was shielded by the basin water. Also, 18 curium sampler slugs, used to produce Cm-244 from Pu-239, were to be disposed of with the cobalt slugs. The curium slugs were also analyzed with a High Purity Germanium (HPGE) detector in an attempt to identify any additional radionuclides produced from the irradiation. Co-60 concentrations were determined for reactor disassembly basin cobalt slugs and the 18 curium sampler slugs. The total Co-60 activity of all of the assayed slugs in this work summed to 31,783 curies on 9/15/03. From the Co-60 concentrations of the curium sampler slugs, the irradiation flux was determined for the known irradiation time. The amounts of Pu-238,-239,-240,-241,-242; Am-241,-243; and Cm-242,-244 produced were then obtained based on the original amount of Pu-239 irradiated

  16. Monte Carlo investigation of design aspects of indigenously developed 120 Ci 60Co based industrial radiography device

    International Nuclear Information System (INIS)

    Palam Selvam, T.; Vishwakarma, R.S.; Sahoo, Dhiren K.; Sharma, Manoj K.; Srivastava, Piyush

    2016-01-01

    Industrial Radiography is an indispensable, versatile and well-established non destructive testing (NDT). Industrial radiography is carried out by using industrial radiography gamma exposure devices (IGRED) housing 60 Co and 192 Ir radioactive sources, and Industrial X-ray machines/accelerators. IGRED is an assembly of components which includes source housing, exposure mechanism, source drive system, pig tail, and source conduit. In the present study, we investigated the shielding design aspects of 120 Ci 60 Co-based IRGED using the Monte Carlo methods (MCNP version 3.1). The design details were provided by Board of Radiation and Isotope Technology (BRIT). As the objective is to finalize the suitable design of the device, we also included additional designs. The work also included measurements around the device using TLDs

  17. Comparative studies on the effect of negative pions, 60Co gamma irradiation and hyperthermia on an in vitro 'tumour model'

    International Nuclear Information System (INIS)

    Luecke-Huhle, C.; Dertinger, H.; Schlag, H.; Weibezahn, K.F.

    1977-01-01

    Multicellular spheriods of Chinese hamster cells (V79) are much more resistant than monolayer cultures of the same cell line; this is observed after 60 Co γ-irradiation, after hyperthermic treatment, after combined treatment of heat with 60 Co γ-radiation and after exposure to negative pi-mesons. Intercellular communication within the three-dimensional cell clones seems to be responsible for an enhanced repair capacity for sub-lethal as well as for potentially lethal damage. While the response of spheroid cells to 60 Co γ-irradiation is almost independent of the state of growth, there is a clear difference in survival whether exponentially growing outer cells or inner plateau phase cells are exposed to heat: moderate heat treatment (4h at 42 0 C) leads to a greater killing efficiency of exponentially growing cells while the inner non-cycling cells exhibit a recruitment of resting cells into the proliferative compartment as demonstrated by means of flow-microfluorometry. Hyperthermia in combination with 60 Co γ-irradiation was shown to eliminate hypoxic cells and to yield a thermal enhancement ratio comparable to the RBE value obtained after pion irradiation at maximum LET. (author)

  18. Nanodefect formation in LiF crystals under gamma irradiation

    International Nuclear Information System (INIS)

    Mussaeva, M.A.; Ibragimova, Eh.M.; Kalanov, M.U.; Muminov, M.I.

    2006-01-01

    One studied the spectra of absorption and of photoluminescence, microhardness and performed X-ray structure analysis of gamma-irradiated LiF crystals in a shutdown reactor and in 60 Co source when gamma-radiation dose rate was equal to 7.65 Gy/s. In addition to formation of point and combined radiation defects one detected the presence of the gamma-irradiation induced 28 nm size nanoparticles of LiOH phase in Li sublattice. Formation of defects is shown to occur more efficiently in a shutdown reactor in contrast to 60 Co source [ru

  19. Constraints on Short, Hard Gamma-Ray Burst Beaming Angles from Gravitational Wave Observations

    Science.gov (United States)

    Williams, D.; Clark, J. A.; Williamson, A. R.; Heng, I. S.

    2018-05-01

    The first detection of a binary neutron star merger, GW170817, and an associated short gamma-ray burst confirmed that neutron star mergers are responsible for at least some of these bursts. The prompt gamma-ray emission from these events is thought to be highly relativistically beamed. We present a method for inferring limits on the extent of this beaming by comparing the number of short gamma-ray bursts (SGRBs) observed electromagnetically with the number of neutron star binary mergers detected in gravitational waves. We demonstrate that an observing run comparable to the expected Advanced LIGO (aLIGO) 2016–2017 run would be capable of placing limits on the beaming angle of approximately θ \\in (2\\buildrel{\\circ}\\over{.} 88,14\\buildrel{\\circ}\\over{.} 15), given one binary neutron star detection, under the assumption that all mergers produce a gamma-ray burst, and that SGRBs occur at an illustrative rate of {{ \\mathcal R }}grb}=10 {Gpc}}-3 {yr}}-1. We anticipate that after a year of observations with aLIGO at design sensitivity in 2020, these constraints will improve to θ \\in (8\\buildrel{\\circ}\\over{.} 10,14\\buildrel{\\circ}\\over{.} 95), under the same efficiency and SGRB rate assumptions.

  20. Gamma (60CO) radiation effects on arcelin protein and evaluation of bean lineages against Acanthoscelides obtectus (Say) and Zabrotes subfasciatus (Boh.) (Col.: Bruchidae)

    International Nuclear Information System (INIS)

    Botelho, Ana Claudia Girardo

    2006-01-01

    The resistance of arcelin carrying seeds of bean lineages (Phaseolus vulgaris L.) against the bean weevils Acanthoscelides obtectus (Say, 1831) and Zabrotes subfasciatus (Bohemann, 1833) (Coleoptera: Bruchidae), and the influence of gamma radiation ( 60 CO) on the manifestation of arcelin resistance to Z. subfasciatus were verified. Laboratorial tests, in choice and non-choice tests, with wild specimens carrying Arc-1, Arc-2, Arc-3, Arc-4, Raz-56 and Raz-59 (with Arc-5 alleles) and commercial lineages as control IAC - Carioca and IAC - Arua were conducted. Statistical design was completely randomized, with five repetitions, with 10 g of grains from each lineage samples by portion. Attractiveness, oviposition, emergence, mortality, adults' weigh and longevity, developing period, sexual rate, seeds' weigh loss, infestation and fecundity (Z. subfasciatus) were observed. Gamma radiation doses irradiations, in general, haven't affected the resistance manifestation of lineages carrying arcelin protein variants against the Z. subfasciatus bean weevil, thus, joint application use of both control methods can be recommended. Raz-56 lineage showed high resistance of the antibiosis types and non-preference for oviposition and feeding to Z. subfasciatus, while Raz-59 showed antibiosis and non-preference for feeding, and both (Raz-56 and Raz-59) showed intermediate resistance to A. obtectus, against which lineage Arc-2 was the most harmful to its development, expressing non-preference to feeding and/or antibiosis. (author)

  1. Tumor induction in mice after local irradiation with single doses of either carbon-ion beams or gamma rays.

    Science.gov (United States)

    Ando, Koichi; Koike, Sachiko; Ohmachi, Yasushi; Ando, Yutaka; Kobashi, Gen

    2014-12-01

    To determine the dose-dependent relative biological effectiveness (RBE) for tumor prevalence in mice receiving single localized doses to their right leg of either carbon ions (15, 45 or 75 keV/μm) or 137Cs gamma rays. A total of 1647 female C3H mice were irradiated to their hind legs with a localized dose of either reference gamma rays or 15, 45 or 75 keV/μm carbon-ion beams. Irradiated mice were evaluated for tumors twice a month during their three-year life span, and the dimensions of any tumors found were measured with a caliper. The tumor induction frequency was calculated by Kaplan-Meier analysis. The incidence of tumors from 50 Gy of 45 keV/μm carbon ions was marginally higher than those from 50 Gy of gamma rays. However, 60 Gy of 15 keV/μm carbon ions induced significantly fewer tumors than did gamma rays. RBE values of 0.87 + 0.12, 1.29 + 0.08 or 2.06 + 0.39 for lifetime tumorigenesis were calculated for 15, 45 or 75 keV/μm carbon-ion beams, respectively. Fibrosarcoma predominated, with no Linear Energy Transfer (LET)-dependent differences in the tumor histology. Experiments measuring the late effect of leg skin shrinkage suggested that the carcinogenic damage of 15 keV/μm carbon ions would be less than that of gamma rays. We conclude that patients receiving radiation doses to their normal tissues would face less risk of secondary tumor induction by carbon ions of intermediate LET values compared to equivalent doses of photons.

  2. Effect of gamma radiation (Co60) in physic-chemical and sensory properties of aged beans (Phaseolus vulgaris, L.)

    International Nuclear Information System (INIS)

    Nascimento, Lenice Magali do

    1992-01-01

    The objective of this work is to evaluate the efficiency of different doses of gamma radiation as an alternative process to improve the quality of aged beans. Beans of the 'Carioca 80' variety were submitted to an accelerated aging process according to the followings patterns: 30 deg C and 50 or 75% relative humidity and 40 deg C and 50 or 80% relative humidity, during 45 days. After that time samples were submitted to gamma irradiation at doses of 300, 600, 900 and 1200 Krad. At the same time samples of 1989, 1987 and 1983 harvest and submitted to slow aging process, 12 deg C and 50-60% relative humidity, were evaluated to comparison with former accelerated aging. All the samples were analysed on moisture and starch content, cooking time, texture and sensorial evaluation. The results showed that samples submitted to aged faster presented better quality, second the evaluated parameters, as far as irradiation applied was 300 Krad. The same happened to samples of harvest 1989 aged slowly. The 1987 and 1983 harvests, respectively, were the doses that gave better softness to the beans. This work permitted conclude that gamma irradiation is an alternative method of advantage for aged beans, for same decrease the cooking time and improvement the sensory quality of stored grain. (author)

  3. Gamma, electron beam and ultraviolet radiation on control of storage rots and quality of Walla Walla onions

    International Nuclear Information System (INIS)

    Lu, J.Y.; Stevens, C.; Yakubu, P.; Loretan, P.A.; Eakin, D.

    1988-01-01

    Walla Walla onions were irradiated with doses of 0.1, 0.3, 1.0, 2.0 and 3.0 kGy of gamma rays; 0.1, 1.0, 2.0, 3.0 and 5.0 kGy of electron beams; or 0.44 × 10 4 1.32 × 10 4 , 3.52 × 10 4 , 7.33 × 10 4 and 19.1 × 10 4 erg/mm± of UV. The onions were stored up to four weeks at 20–25 C. UV irradiated onions exhibited the greatest percentage of marketable onions and reduction in postharvest rots. Sprouting was obsened with control, UV and electron beam irradiated onions but not with gamma irradiated onions. Effect of gamma, electron beams and UV on pH, moisture, ascorbic acid and color were not significant. Onions became soft with the high dose of gamma radiation (3.0 kGy). Total sugar content was not affected by UV and electron beam but tended to be greatest at the 1.0 kGy gamma radiation. The effect of the radiation on the onion sensory scores was not clearly indicated except that 3.0 kGy gamma ray irradiated onions had the lowest firmness score

  4. Batteryless {gamma}-Ray Dosimeter; Dosimetre de rayons {gamma}, sans batteries; {gamma}-dozimetr bez batarei; Dosimetro a rayos {gamma} sin bateria

    Energy Technology Data Exchange (ETDEWEB)

    Gross, Bernhard [National Institute of Technology, Rio de Janeiro (Brazil)

    1960-06-15

    The Compton current produced by X-rays and {gamma}-rays in the 0.3 to 3 MeV range is proportional to the radiant energy flux. Therefore the intensity of the current can be used as a measure of radiation dose. The present paper describes a radiation receiver and electrical measuring system suitable for Compton current measurements and results obtained with this device under irradiation from a 2000 curie Co{sup 60} source. (author) [French] Le courant de Compton produit par des rayons X et {gamma} dans le domaine d'energies compris entre 0,3 et 3 MeV est proportionnel au flux d'energie rayonnante. C'est pourquoi l'intensite du courant peut servir de mesure de la dose de rayonnements. Le memoire decrit un ensemble, appareil recepteur de rayonnements et appareil de mesure electrique, permettant de mesurer le courant de Compton et il expose les resultats obtenus, au moyen de ce dispositif, sous irradiation par une source de Co{sup 60} de 2000 curies. (author) [Spanish] La corriente de Compton producida por rayos X y rayos {gamma} de energia comprendida entre 0,3 y 3 MeV es proporcional al flujo de energia radiante. Por consiguiente, la intensidad de la corriente puede servir para medir la dosis de radiacion. En este trabajo se describen un receptor de radiaciones y un sistema de medicion electrica apropiados para determinar la intensidad de la corriente de Compton, asi como los resultados obtenidos mediante este dis- positivo cuando se irradia con una fuente de Co{sup 60} de 2000 curies. (author) [Russian] Komptonovskij potok, obrazuemyj rentgenovskim i luchami i {gamma}-luchami v predelakh ot 0,3 do 3 mehv, proportsionale n potoku luchistoj ehnergii. Poehtomu intensivnost' potoka mozhet byt' ispol'zovana dlya izmereniya dozy radiatsii. V nastoyashchem dokumente opisyvayutsya radiatsionny j priemnik i ehlektricheskaya izmeritel'naya sistema, prigodnye dlya izmerenij s pomoshch'yu komptonovskog o potoka, i rezul'taty, poluchennye s pomoshch'yu ehtogo ustrojstva v khode

  5. Gamma-Ray Pulsars: Beaming Evolution, Stats and Unident. EGRET Sources

    OpenAIRE

    Yadigaroglu, I. -A.; Romani, Roger W.

    1994-01-01

    We compute the variation of the beaming fraction with the efficiency of high energy gamma-ray production in the outer gap pulsar model of Romani and Yadigaroglu. This allows us to correct the fluxes observed for pulsars in the EGRET band and to derive a simple estimate of the variation of efficiency with age. Integration of this model over the population of young neutron stars gives the expected number of gamma-ray pulsars along with their distributions in age and distance. This model also sh...

  6. Changes in lens following 60Co irradiation

    International Nuclear Information System (INIS)

    Rozsival, P.; Obenberger, J.; Sladkova, J.

    1985-01-01

    Chinchilla rabbit lenses were irradiated using a 60 Co gamma source, and the changes in the transport activities, native weight, water content and dry weight were observed. The heads of rabbits were irradiated with doses of 10 and 20 Gy and functional changes occurring in the lenses were studied till the twenty-fourth week after the irradiation. The weight of the rabbit lens irradiated with a dose of 20 Gy significantly increased after the twelfth week and was maximal 16 weeks after irradiation when also cataracts were observed. The increased weight of lenses was caused by accumulation of water. The decrease in the dry weight of lenses preceded the period of visible cataracts. A decreased uptake of rubidium occurring during in vitro cultivation of lenses was the most sensitive marker for the changes caused by 20 Gy irradiation. It was significantly decreased as early as 8 weeks after irradiation, preceding the increased hydration of lenses by 4 weeks and the presence of visible cataracts by as much as 8 weeks

  7. Determination of contamination-free build-up for 60Co

    International Nuclear Information System (INIS)

    Higgins, P.D.; Sibata, CH.; Paliwal, B.R.

    1985-01-01

    Experimental verification of the difference between absorbed dose in tissue and the collision fraction of kerma requires precise knowledge of the absorbed dose curve, particularly in the build-up and build-down regions. A simple method from direct measurement of contamination-free build-up for 60 Co, which should also be applicable for most of the photon energies commonly employed for treatment, is presented. It is shown that the contribution from air-scattered electrons to the surface dose may be removed by extrapolating measurements of build-up to zero field size. The remaining contribution to contamination from the collimators and other source-related hardware may be minimised by measuring these build-up curves sufficiently far from the source. These results were tested by measuring the build-up using a magnet to sweep scattered electrons from the primary photon beam and by measuring the surface dose in the limit of an evacuated beam path. The relative dose at zero depth in polystyrene was found to be approximately 8.9+-0.3% of the dose at the depth of maximum build-up. (author)

  8. Dosimetry of electron and gamma radiation with DL-alanine

    International Nuclear Information System (INIS)

    Costa, Z.M. da; Campos, L.L.

    1996-01-01

    A dosimetric method based on the quantitative determination of stabilised free radicals in irradiated crystalline DL-alanine by electron spin resonance (ESR) spectroscopy was proposed as early in 1962. Since then, alanine dosemeters owing to their unique properties have been investigated by many authors and used in dosimetry of various types of radiation, namely gamma rays, electron and neutrons. Alanine is a simple aminoacid, on irradiation at room temperature predominantly free paramagnetic radicals of the type CH 3 -CH-COOH are produced. This paper reports the application of powder DL-alanine/ESR dosemeter for measurement of absorbed dose of gamma radiation from 60 Co sources and reactor nucleus and electron beams from accelerator. The obtained results give useful information about the instrumental care necessary to obtain the needed overall accuracy in determination of absorbed dose. (author)

  9. Transfer Factor of Co-60 and Cs-137 from Agricultural Soil to Agricultural Plant of Rice and Beans

    International Nuclear Information System (INIS)

    Suzie, D; Cerdas, T; Susilah, S; Umbara, H

    1996-01-01

    A study to estimate transfer factor of Co-60 and Cs-137 radionuclides from agricultural soil to agricultural plant of beans and rice in Serpong Nuclear Research Center Complex has been carried out. The soil used was that from off site Serpong Nuclear Research Center Complex, the agricultural plant samples were rice with variety of Cisadane, Situgintung, Seratus Malam, and Atomita 4, and for beans were peanut with variety of AH 1781 SI (parent) and A 20 psj (daughter), soybean with variety of Kerinci (parent) and Camar (daughter), and greenbean with variety of Manyar (parent) and Camar (daughter), which obtained from PAIR-BATAN Pasar Jumat. 10 kg of soil was put on the container which layered with plastic. The soil was contaminated with Co-60 and Cs-137 with activity concentration of 10 Bq/kg. Samples were counted with gamma spectrometer. The value of transfer factor was obtained by comparing activity concentration of agricultural plant with that of agricultural soil. The results of transfer factor of Co-60 for rice and beans were 0.12 x 10-2 and 1.05 x 10-2, respectively and the transfer factor of Cs-137 for rice and beans were 0.83 x 10-2 and 2.09 x 10-2, respectively. The gamma emmitter radionuclides counted from the soil of Serpong Nuclear Research Center Complex were Th-228, U-235, Ra-226, Ac-228 and K-40, with activities concentration as background were 35.39 - 101.60; 32.14 - 74.50; 23.37 - 28.57; 20.90 - 31.28 and 5.97 - 8.13 Bq/kg, respectively

  10. Effect of 60 Co gamma radiation on trehalose level of Saccharomyces boulardii cells

    International Nuclear Information System (INIS)

    Santos, Raquel Gouvea dos; Neves, Maria Jose; Duarte, Rinaldo; Nicoli, Jacques R.

    1996-01-01

    The medicine Floratil used for diarrhea treatment is composed by lyophilized yeast cells of Saccharomyces boulardii. The action mechanism of this product is unknown. The efficacy of S. boulardii depends on its viability. The increase in the trehalose level in S. cerevisiae cells submitted to a previous sub-lethal level heat shock results in resistance to a lethal shock. The aim of this work was to study weather the cell trehalose level is involved also in the resistance of gamma irradiation. It was noted that the yeast cells surviving to gamma irradiation had more trehalose level than control cells. Apparently there is a positive correlation between of trehalose level and gamma irradiation resistance of S.boulardii cells. (author)

  11. Evaluation of Radiosensitivity of HeLa Cells Infected with Polio Virus Irradiated by Co 60

    Directory of Open Access Journals (Sweden)

    F Seif

    2008-04-01

    Full Text Available ABSTRACT: Introduction & Objective: The main purpose of radiotherapy is exposing enough doses of radiation to tumor tissue and protecting the normal tissues around it. Tumor dose for each session in radiotherapy will be considered based on radiosensitivity of the tissues. The presence of viral diseases in tumoral area can affect the radiosensitivity of cells. This study aimed to evaluate the radiosensitivity of Hela cells infected with poliomyelitis virus irradiated by Co 60. Materials & Methods: In this study, the radiosensitivity of HeLa cells, with or without the viral infection, after gamma radiation of cobalt 60, was assessed. Results: Results of comparison of the radisensitivity of infected and uninfected cells indicates that after 2 Gy irradiation by Co 60, polio infection in low, moderate and high virus load, increases the cell death by 20-30%, 30-40% and 70-90% respectively. Conclusion : Radiosensitivity of tumoral cells increase when they are infected with viral agents. Results of this study showed that non cancer diseases should be considered when prescribing dose fraction in radiotherapy of cancers.

  12. Two Dimensional Verification of the Dose Distribution of Gamma Knife Model C using Monte Carlo Simulation with a Virtual Source

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae-Hoon; Kim, Yong-Kyun; Lee, Cheol Ho; Son, Jaebum; Lee, Sangmin; Kim, Dong Geon; Choi, Joonbum; Jang, Jae Yeong [Hanyang University, Seoul (Korea, Republic of); Chung, Hyun-Tai [Seoul National University, Seoul (Korea, Republic of)

    2016-10-15

    Gamma Knife model C contains 201 {sup 60}Co sources located on a spherical surface, so that each beam is concentrated on the center of the sphere. In the last work, we simulated the Gamma Knife model C through Monte Carlo simulation code using Geant4. Instead of 201 multi-collimation system, we made one single collimation system that collects source parameter passing through the collimator helmet. Using the virtual source, we drastically reduced the simulation time to transport 201 gamma circle beams to the target. Gamma index has been widely used to compare two dose distributions in cancer radiotherapy. Gamma index pass rates were compared in two calculated results using the virtual source method and the original method and measured results obtained using radiocrhomic films. A virtual source method significantly reduces simulation time of a Gamma Knife Model C and provides equivalent absorbed dose distributions as that of the original method showing Gamma Index pass rate close to 100% under 1mm/3% criteria. On the other hand, it gives a little narrow dose distribution compared to the film measurement showing Gamma Index pass rate of 94%. More accurate and sophisticated examination on the accuracy of the simulation and film measurement is necessary.

  13. TLD Postal service for quality audits of beams of Co-60 in reference conditions in Cuba

    International Nuclear Information System (INIS)

    Gutierrez L, S.; Walwyn S, G.; Alonso V, G.

    2006-01-01

    Purpose: To describe the methodology and experience of the Secondary Laboratory of Dosimetric Calibration of Cuba in the establishment of the TLD Postal Service for quality audits of beams of Co-60 in reference conditions. Materials and methods: Through the Coordinated Project of Research (Contract 10794) its was bought 200 solid thermoluminescent detectors of LiF: Mg, Ti (TLD-100) in micro bars form with dimensions of 6 x 1 x 1 mm and of the JR 1152F type manufactured in China. All these detectors were identified individually with a serial number on one of its faces, using a graphite fine sheet. Those detectors for its irradiation are introduced in cylindrical plastic capsules developed and used by the International Atomic Energy Agency (IAEA) in the Audit Postal Service of Dose IAEA/WHO, the capsules have one cavity equal to 3 mm for that is necessary to recover this cavity with a fine plastic tube so that the detectors remain immobile during the irradiation. The method used to determine the individual sensitivity of the thermoluminescent detectors is: to irradiate a detectors group (100 micro bars) 4 times in those same geometric conditions, with the same irradiation history and reading, then it is determine for each detector a sensitivity factor equal to the average of those readings obtained for the 4 irradiation cycles for each i detector among the average of all the reading values obtained during the 4 cycles. The thermoluminescent signal is obtained with a Harshaw 2000C/B reader manual. Results: The satisfactory results obtained in the verification of the calibration of the TLD system, using the reference irradiation service of the Seibersdorf Dosimetry Laboratory of the IAEA in three different years are shown. The results of the audits carried out to the different radiotherapy services of the country in different years are also presented. Conclusions: The experience with the detectors acquired in the project demonstrates that with an appropriate

  14. A GIF++ Gamma Irradiation Facility at the SPS H4 Beam Line

    CERN Document Server

    Capéans-Garrido, M; Linssen, L; Moll, M; Rembser, C

    2009-01-01

    The current document describes a proposal to implement a new gamma irradiation facility, combined with a high-energy particle beam in the SPS H4 beam line in hall EHN1. This new GIF++ facility is motivated by strong needs from the LHC and sLHC detector and accelerator communities for the tests of LHC components and systems.

  15. Study of gamma radiation from {sup 60}Co effects on Apis mellifera venom: biochemical, pharmacological and immunological aspects; Estudo dos efeitos da radiacao gama de {sup 60}Co na peconha de Apis mellifera: aspectos bioquimicos, farmacologicos e imunologicos

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Helena

    2001-07-01

    Africanized honeybees are very common insects in Brazil and frequently cause accidents followed by important immunological reactions and even deaths. Their venoms are composed of a complex mixture of substances of general biological actions. Ionizing radiation is able to modify molecular structures affecting the biological properties of proteins. It decreases toxic and enzymatic activities and so, it appears promising as a venom detoxification tool. The main objective of this work was to study the effects of gamma radiation on bee venom, regarding biochemical, pharmacological and immunological aspects. Africanized Apis mellifera whole venom (2 mg/ml) in 0.15 M NaCl solution was irradiated with 2 kGy in a {sup 60}Co source. Native and irradiated bee venoms were submitted to high performance size exclusion chromatography (Tosohaas G2000SW column), high performance reversed phase chromatography in a C-18 column under water/acetonitrile gradient, SDS-PAGE. For both venoms studies have been carried out in UV absorption spectrum, protein concentration, hemolytic activity, and PLA{sub 2} activity analysis, lethality assay (LD{sub 50}). Biodistribution studies was carried out after labelling native and irradiated bee venom with {sup 99m}Tc. The results showed that gamma radiation did not change the protein concentration nor its immunogenicity, although it could be observed that irradiated bee venom UV spectrum and SDS-PAGE profile presented differences when compared to native bee venom. This suggests that some structural alterations in bee venom components could have occurred after irradiation. HPLC-RP profiles showed that gamma radiation could have caused conformational changes, such as unfolding of molecule chains, changing their hydrophobic groups exposuring. The hemolytic and the PLA{sub 2} activities of irradiated bee venom were smaller than the native ones. The gamma radiation diminished the toxicity of bee venom, but did not abolish its bioactivity, like hemolysis

  16. Viabilidade e micoflora de sementes de amendoim irradiadas com cobalto (60Co Viability and mycoflora of irradiated seeds of peanut with cobalt (60Co

    Directory of Open Access Journals (Sweden)

    Niédja M. C. Alves

    2011-03-01

    Full Text Available Estudou-se o efeito de diferentes doses da irradiação gama na germinação e percentagem de infecção fúngica em sementes de amendoim cultivar BR1. Inicialmente, as sementes foram avaliadas quanto à micoflora, utilizando-se o método de papel de filtro umedecido, a germinação em substrato de papel germitest e determinação do teor de umidade em estufa, a 105 ± 2 ºC. Posteriormente, as sementes foram submetidas à irradiação com uma fonte de 60Co, tipo gammacell, onde se estudou o efeito de 8 doses de irradiação na micoflora e germinação das sementes acondicionadas em embalagem de PET e polietileno trançado durante 60 dias de armazenamento, sem controle de temperatura e umidade relativa do ar. Os fatores estudados (doses em kGy, embalagens e tempo de armazenamento foram analisados em um delineamento inteiramente casualizado, dispostos em fatorial. Com base nos resultados, observou-se que a irradiação gama afetou negativamente a germinação das sementes de amendoim e que doses acima de 3,0 kGy comprometem a germinação das sementes. A radiação a partir da dose 1,5 kGy eliminou os fungos Aspergillus niger e, Penicillium a partir da dose de 2,5 kGy.The effect of different doses of the gamma irradiation was studied on germination and percentage of fungal infection in peanut seeds cultivar BR1. Initially the seeds were evaluated for the mycoflora using the method of humidified filter paper, the germination in paper substratum germitest and determination of the moisture content in oven at 105 ± 2 ºC. Later on the seeds were submitted to irradiation with a source of 60Co, type gammacell, where the effect was studied of 8 doses of irradiation in the mycoflora and germination of the seeds conditioned in PET packing and polyethylene tressed during 60 days of storage, without control of temperature and relative humidity of the air. The studied factors (doses in kGy, packing and time of storage were analyzed in a completely

  17. The cryogenic silicon Beam Tracker of NA60 for heavy ion and proton beams

    International Nuclear Information System (INIS)

    Rosinsky, P.; Borer, K.; Casagrande, L.; Devaux, A.; Granata, V.; Guettet, N.; Hess, M.; Heuser, J.; Jarron, P.; Li, Z.; Lourenco, C.; Manso, F.; Niinikoski, T.O.; Palmieri, V.G.; Radermacher, E.; Shahoyan, R.; Sonderegger, P.

    2003-01-01

    The cryogenic silicon Beam Tracker of NA60 is the first detector based on the Lazarus effect used in a high-energy physics experiment. It employs single-sided silicon strip sensors of 50 μm pitch operated at a temperature of 130 K. Two tracking stations determine the transverse coordinates of the interaction point at the target with 20 μm resolution, to improve the determination of the offset of secondary vertices. This impact parameter measurement allows NA60 to distinguish between prompt dimuons and muon pairs from D-meson decays. The detector concept and technical feasibility have been demonstrated in beam time periods between 1999 and 2002

  18. Cytotoxicity evaluation of Diethyltoluamide (DEET) in Perna perna (Linnaeus, 1758) mussels non-irradiated and irradiated with 60Co gamma radiation

    International Nuclear Information System (INIS)

    Martini, Gisela de Assis

    2013-01-01

    Recent studies have identified the presence of several emerging pollutants in aquatic environments. The occurrence in different environmental matrices has been continuously reported, highlighting the need for toxicity studies. The DEET (N,N-diethyl-meta-toluamide) is the active ingredient used in most insect repellents, and is present in many commercially available formulations. Apart from chemical pollutants, aquatic organisms are subject to exposure of ionizing radiation from natural sources or in the vicinity of nuclear power plants. The present study evaluated the toxicity of DEET in organisms irradiated and non-irradiated with 60 Co gamma radiation, and the effects that radiation causes in lysosomes of hemocytes of Perna perna mussel. For this purpose, assays were performed to identify the acute toxicity of DEET concentration and the dose of gamma radiation able to cause mortality. Subsequently, cytotoxicity assays were carried out to assess the stability of the lysosomal membrane in organisms exposed to ionizing radiation and DEET. According to the results obtained in acute toxicity tests, the concentration of DEET that causes mortality of 50% exposed organisms (LC50) is 114,27 mg L -1 , and the radiation dose that causes mortality (LD50) is 1068 Gy. In the cytotoxicity assays, the concentration of the non-observed effect (NOEC) for irradiated and non-irradiated organisms 0.0001 mg L-1 and observed effect concentration (LOEC) at concentrations above this. The IC25 (72h) for non-irradiated organisms was 0.0003 mg L-1 and IC50 (72h) was 0.0008 mg L -1 for irradiated and non-irradiated organisms. Despite of the concentrations of effect found in this study were higher than in the environment, both measurements are in the same order of magnitude and should be also take into account the possible synergistic effects of DEET with other contaminants in the aquatic environment. (author)

  19. The effect of gamma ray on growth and anatomy structure of garlic leaf (A. sativum L.)

    International Nuclear Information System (INIS)

    Sumiyarsih, S.; Aliudin

    1990-01-01

    This experiment was conducted in Experimental Garden Banaran, East Java. This experiment used Complete Randomized Design with 10 replications and 7 treatments as followed: garlic seeds were radiated by gamma Co 60, with dosage 0, 2, 4, 6, 8, 10, and 12 krad. The result of this experiment showed that radiated treatment of gamma Co 60 ray decreased growth percentage, plants became dwarf, root growth was short, and dosage 10 and 12 krad resulted in rotten root. Also radiation of gamma Co 60 decreased number of stomata and diameter of trachea became smaller

  20. Establishing the estimation model on radiation level at the ambience of 60Co radiotherapy treatment room based on NCRP REPORT No.151

    International Nuclear Information System (INIS)

    Yang Haiyou; Liu Liping; Liang Yueqin; Yu Shui

    2009-01-01

    Objective: To establish the estimation model to evaluate the radiation level at the ambience of 60 Co radiotherapy treatment room. Methods: The estimation model derives from NCRP REPORT No.151- S tructural Shielding Design and Evaluation for Megavoltage X-and Gamma-Ray Radiotherapy Facilities b y making appropriate adjustment, which presents the calculation methods on radiation level at the ambience of megavoltage medical electron linear accelerator treatment room. Results: The application scope of estimation model from NCRP REPORT No.151 is extended to γ-radiotherapy facilities, and it can be regarded as a new model for calculating the radiation level at the ambience of 60 Co radiotherapy treatment room. Conclusion: The estimation model has certain reference value to evaluate the radiation level at the ambience of 60 Co radiotherapy treatment room. (authors)

  1. Effects of gamma irradiation of the 60 Co on antimicrobial action of plant extracts of bark and leaves of Schinus terebinthifolius Raddi

    International Nuclear Information System (INIS)

    Silva, Edvane Borges da; Santos, Gustavo Henrique Farias dos; Amaral, Ademir de Jesus; Xisto, Kesia; Araujo, Rosilma de Oliveira

    2014-01-01

    This study aimed to evaluate the potential for antimicrobial activity in vitro of extracts of bark and leaves of S. terebinthifolius treated with 60 Co gamma radiation. 5,0 doses were used; 7.5 and 10 kGy, being held non-irradiated controls. To determine the antimicrobial activity was applied to the disc diffusion technique to evaluate the diameter of the inhibition zones against Gram-positive bacteria, gram-negative bacteria, alcohol-acid-resistant and yeast. Antimicrobial activity was considered significant for halos ≥ 15 mm. The results indicate an intensification of antimicrobial action of bark extracts, the 5.0 kGy, against S. aureus. Was held the micro dilution in broth to determine the minimum inhibitory concentration (MIC) and Minimum Bactericidal Concentration (MBC) of peels extracts, compared to eight clinical isolates of S. aureus. The MBC values showed that ionizing radiation did not produce the increased of anti bacteriostatic action of S. terebinthifolius, but the results indicated that S. terebinthifolius bark extracts can be used as an antimicrobial agent and ionizing radiation as an important alternative in this conservation feature

  2. Comparison of skin doses to large fields using tangential beams from cobalt-60 gamma rays and 4-MV x rays

    International Nuclear Information System (INIS)

    Gagnon, W.F.; Peterson, M.D.

    1978-01-01

    Excess radiation to the skin during external beam megavoltage radiation therapy has reportedly caused excessive erythema in patients treated with the Clinac 4 linear accelerator on sloping surfaces, but not for similar treatments with cobalt-60. Doses at the epidermal level were measured under geometries simulating sloping surfaces for a Clinac 4 and an Eldorado 8 cobalt-60 teletherapy machine. For equal doses to the axilla, doses to the epidermal layer were similar. When the tumor dose was calculated for the mediastinum, the dose to the skin in the axillary region was 12% higher for the Clinac 4

  3. Sensory evaluation of black beans submitted to gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Moura, Neila Camargo de; Canniatti-Brazaca, Solange Guidolin; Spoto, Marta Helena Fillet; Arthur, Valter

    2005-01-01

    The objective of this research was to evaluate the sensory aspects of black beans submitted to gamma radiation from 60 Co. The study involved eight panelists, between 17 to 23 years old, who were selected and trained for the descriptive analysis of appearance, aroma, flavor and texture. The panelists analyzed alterations of appearance, aroma, flavor and texture of non-irradiated and irradiated black beans with doses 2, 4, 6, 8 and 10kGy. The results were analyzed by test F, ANOVA and the Tukey test (5%), with the use of computers and the sensory analysis software Compusense Five and SAS. The results showed that irradiated samples decreased the bitter flavor, accentuated color and brightness and samples non-irradiated dry texture. The radiation treatment is a good method for conservation of black beans in doses evaluated in this study.(author)

  4. Detection of an intense polychromatic gamma beam modulated at 3000 MHz; Detection d'un faisceau intense de gammas polychromatiques module a 3000 MHz

    Energy Technology Data Exchange (ETDEWEB)

    Beil, H; Veyssiere, A; Daujat, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    This paper presents two methods of detection of a {gamma} beam modulated at very high frequencies. The intense modulated beam is created by means of Bremsstrahlung in a gold-target, the latter having been placed in the emerging electron beam of the Linac at Saclay. A tentative interpretation of the physical phenomena involved in the detection processes is also given. The empirical data agree reasonably well with numerical evaluations based on well established theoretical concepts concerning these phenomena. (authors) [French] Cet article presente deux facons de detecter un faisceau de {gamma} module a haute frequence. Le faisceau intense de {gamma} est cree par l'impact d'electrons (acceleres dans un accelerateur lineaire) sur une cible en or. Une tentative d'interpretation des phenomenes physiques mis en cause dans le processus de detection est donnee et les valeurs experimentales trouvees s'accordent raisonnablement bien avec les valeurs calculees a partir des considerations theoriques des phenomenes. (auteurs)

  5. Dosimetric Consistency of Co-60 Teletherapy Unit- a ten years Study.

    Science.gov (United States)

    Baba, Misba H; Mohib-Ul-Haq, M; Khan, Aijaz A

    2013-01-01

    The goal of the Radiation standards and Dosimetry is to ensure that the output of the Teletherapy Unit is within ±2% of the stated one and the output of the treatment dose calculation methods are within ±5%. In the present paper, we studied the dosimetry of Cobalt-60 (Co-60) Teletherapy unit at Sher-I-Kashmir Institute of Medical Sciences (SKIMS) for last 10 years. Radioactivity is the phenomenon of disintegration of unstable nuclides called radionuclides. Among these radionuclides, Cobalt-60, incorporated in Telecobalt Unit, is commonly used in therapeutic treatment of cancer. Cobalt-60 being unstable decays continuously into Ni-60 with half life of 5.27 years thereby resulting in the decrease in its activity, hence dose rate (output). It is, therefore, mandatory to measure the dose rate of the Cobalt-60 source regularly so that the patient receives the same dose every time as prescribed by the radiation oncologist. The under dosage may lead to unsatisfactory treatment of cancer and over dosage may cause radiation hazards. Our study emphasizes the consistency between actual output and output obtained using decay method. The methodology involved in the present study is the calculations of actual dose rate of Co-60 Teletherapy Unit by two techniques i.e. Source to Surface Distance (SSD) and Source to Axis Distance (SAD), used for the External Beam Radiotherapy, of various cancers, using the standard methods. Thereby, a year wise comparison has been made between average actual dosimetric output (dose rate) and the average expected output values (obtained by using decay method for Co-60.). The present study shows that there is a consistency in the average output (dose rate) obtained by the actual dosimetry values and the expected output values obtained using decay method. The values obtained by actual dosimetry are within ±2% of the expected values. The results thus obtained in a year wise comparison of average output by actual dosimetry done regularly as a part of

  6. Comparison of the effects of gamma ray and e-beam irradiation on the quality of minced beef during storage

    International Nuclear Information System (INIS)

    Park, Jae Nam; Han, In Jun; Kim, Wang Geun; Song, Beom Seok; Kim, Jae Hun; Choi, Jong Il; Yoon, Yo Han; Byun, Myung Woo; Hwang, Han Joon; Lee, Ju Woon; Park, Jin Gyu

    2009-01-01

    This study was conducted to compare the microbiological and physicochemical qualities of minced beef irradiated with gamma ray of e-beam at the absorbed doses from 5 to 20 kGy. The total bacterial counts of minced beef were decreased depending upon the irradiation doses, but sterilizing effect of gamma irradiation was higher than that of e-beam irradiation. The contents of malondialdegyde of minced beef were increased depending upon irradiation doses as well as storage periods (p< 0.05). Volatile basic nitrogen in minced beef was constantly increased during storage, but the increasing rate were retarded by irradiation. The hunter's color values(L*, a* and b*) of gamma or e-beam irradiated minced beef were decreased as irradiation dose increasing. Meanwhile, the quality changes of gamma irradiated samples were faster than e-beam irradiated samples

  7. Thermal stability of formulations of PVC irradiated with {gamma} of {sup 60}; Estabilidad termica de formulaciones de PVC irradiadas con {gamma} de {sup 60} Co

    Energy Technology Data Exchange (ETDEWEB)

    Martinez P, M.E.; Carrasco A, H. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)]. E-mail: memp@nuclear.inin.mx; Castaneda F, A.; Benavides C, R.; Garcia R, S.P. [CIQA, 25100 Saltillo, Coahuila (Mexico)

    2004-07-01

    The industry of cables and wires frequently use cable isolations with base of formulations of PVC, in those that stabilizer has usually been used with the help of heavy metals, as the lead, which is toxic. To solve the problem, from the 2002 one has come studying in combined form in the National Institute of Nuclear Research ININ and the Center of Investigation in Applied Chemistry CIQA, the modifications induced by the radiation in formulations with the help of vinyl poly chloride PVC. In these formulations, prepared with cross linking agent, plastifying industrial grade, stuff and non toxic stabilizers of calcium estearate and zinc industrial grade, it is sought to replace the stabilizer of Pb. For this were irradiated it test tubes of PVC with gamma radiation of cobalt 60 to three different dose in atmospheres of air and argon. Later it was determined their thermal stability at different times of heating and it was measured the Young modulus by means of thermo mechanical analysis. Those results obtained together with other techniques of characterization suggest that the irradiated proposed formulation can substitute the one stabilized with lead. (Author)

  8. Load of Co-60 in large gamma irradiators: a safe proceeding; Carregamento de Co-60 em irradiadores de grande porte: um procedimento seguro

    Energy Technology Data Exchange (ETDEWEB)

    Luca, Gilmara C.; Paquer, Daniela, E-mail: gilmara@cbesa.com.b, E-mail: daniela@cbesa.com.b [CBE Embrarad, Jarinu, SP (Brazil)

    2011-10-26

    The inclusion of new Co-60 sources in industrial irradiators is an extra procedure to its operation and extremely critical. The operation requires planning, attention, responsibility and a well trained staff. Radiation level, package contamination and radioactive material escape evaluations are essential as measurement of pre-loading safety. The package transfer for the swimming pool i e the most critical moment of the operation. After sources transfer to the racks, it is necessary the monitoring of tools, package and sources through the scrubbing test. Notwithstanding to be a critical operation, the risk is minimized when it is performed according to safe rules and radiation protection, and in the process performed the individual accumulated doses does not exceed 50 to {mu}Sv

  9. A comparison of Australian and Canadian calibration coefficients for air kerma and absorbed dose to water for 60Co gamma radiation.

    Science.gov (United States)

    Shortt, K R; Huntley, R B; Kotler, L H; Boas, J F; Webb, D V

    2006-06-01

    Australian and Canadian calibration coefficients for air kerma and absorbed dose to water for 60Co gamma radiation have been compared using transfer standard ionization chambers of types NE 2561 and NE 2611A. Whilst the primary standards of air kerma are similar, both being thick-walled graphite cavity chambers but employing different methods to evaluate the Awall correction, the primary standards of absorbed dose to water are quite different. The Australian standard is based on measurements made with a graphite calorimeter, whereas the Canadian standard uses a sealed water calorimeter. The comparison result, expressed as a ratio of calibration coefficients R=N(ARPANSA)/N(NRC), is 1.0006 with a combined standard uncertainty of 0.35% for the air kerma standards and 1.0052 with a combined standard uncertainty of 0.47% for the absorbed dose to water standards. This demonstrates the agreement of the Australian and Canadian radiation dosimetry standards. The results are also consistent with independent comparisons of each laboratory with the BIPM reference standards. A 'trilateral' analysis confirms the present determination of the relationship between the standards, within the 0.09% random component of the combined standard uncertainty for the three comparisons.

  10. Ionizing radiation from 60Co and electron accelerator in reducing the population of Salmonella sp. inoculated in chicken meatballs: evaluation of acceptance by consumer

    International Nuclear Information System (INIS)

    Saito, Juliana

    2003-01-01

    Salmonella sp. is one of the main microorganisms that causes outbreaks of food borne diseases associated to poultry, and among its derivatives, the chicken meatballs are getting the favorites of the consumer. In the attempt to improve microbiological food safety, a method that has been hardly studied is the irradiation. To study the viability of the use o ionizing radiation originated from 60 Co and electrons accelerator in the reduction of Salmonella sp., frozen chickens meatballs were inoculated with 10 4 CFU/g of Salmonella sp., with needle and syringe. Subsequently they were exposure to doses of 1.5, 2.0, 2.5 and 3.0 kGy and Salmonella sp. was enumerated. Chicken meatballs were exposed to doses 3.0, 4.0 and 5.0 kGy and submitted to sensory analysis. The gamma radiation from 60 CO was effective in the reduction of Salmonella sp. inoculated in chicken meatballs. The ionizing radiation originated from electron beam was not effective in the conditions applied in this research. The commercial chicken meatballs prepared with chicken meat, mixed up with soy protein, seasoning and anti-oxidants additives did not loose their sensorial quality when exposure to doses of 3.0, 4.0 and 5.0 kGy and, in a general way, the consumers showed to be disposed to buy the irradiation product (author)

  11. Effect of the irradiation on Salmonella enteretidis var. typhimurium with gamma rays from 60Co

    International Nuclear Information System (INIS)

    Maliska, C.; Norberg, A.N.; Norberg, J.B.M.; Santos Souza, R.C. dos; Silva Tavares, P.R. da

    1988-01-01

    The use of ionizinf radiation to the destruction of microrganisms responsible for food deterioration, and productive of feeding toxinfections constitute their usefulness for actually peaceful goals of nuclear energy. The feeding toxinfections are, among us, produced in their most part by Salmonella enteritidis var. typhimurim. One hundred nineteen samples of milk containing about 150.000 bacteria per ml, by means doses ranging from 100 to 1.100 gy, two samples of surviving bacteria were again irradiated by doses up to 2.5000 Gy. The bacteria not previously irradiated were throughly killed by means of doses of 1.100 Gy. Salmonella enteritidis var. typhimurium was inactivated by means of 1.200 and 1.900 Gy doses. It was concluded that 60-Cobalt gamma radiation minimal lethal dose to Salmonella enteritidis var. typhimurium is 1.200 Gy; the re-irradiation to the survivors prompts the forthcoming of more resistant germs. (author) [pt

  12. Cobalt 60 gamma irradiation current status, trends and insights

    International Nuclear Information System (INIS)

    Corley, John T.

    1998-01-01

    This paper discusses the current status, trends and insights into the continued, safe use of cobalt 60 gamma irradiation. Also presented are some of the many initiatives undertaken at MDS Nordion. Topics covered include our investment for the future supply of raw materials and the latest news from source production. Briefly presented are the tasks associated with the safe transport of cobalt 60 around the world. Discussed is cobalt 60 usage at the customer site; more specifically maintaining source integrity, source utilization and irradiator design trends. Highlighted are industry trends for North America, Europe and the rest of the world. Finally presented are the challenges and opportunities for the industry. Stressed in the paper is the need to work together

  13. Dosis óptima de irradiación gamma con Co60 para inducción de mutagénesis en pastos

    Directory of Open Access Journals (Sweden)

    Alan Álvarez-Holguín

    2017-01-01

    Full Text Available La dosis letal (DL 50 y reducción media del crecimiento (RC 50 son parámetros utilizados para seleccionar dosis de irradiación adecuadas e inducir mutaciones para realizar mejoramiento genético vegetal. El objetivo fue determinar la DL 50 y RC 50 para conocer la dosis ó p tima de irradiación c on Co 60 en semilla de pasto llorón, buffel, banderita y navajita. Se evaluaron seis dosis de irradiación con Co 60 en semilla : 100, 200, 300, 450, 600 y 900 Gray (Gy y un tratamiento control (T - 0, sin irradiación. Las variables evaluadas fueron : porcentaj e de germinación (%GE, índice de velocidad de germinación (IVG, longitud de plúmula (LP y longitud de radícula (LR. Se realizó análisis de regresión y comparación de medias con la prueba de Dunnett. Mediante la ecuación de regresión se estimó la DL 50 p ara el %GE, así como RC 50 para el resto de las variables. La DL 50 se ponderó con 55%, mientras que la RC 50 se ponderó en 15% para cada una de las tres variables restantes. En general, los valores de las variables disminuyeron (P<0.05 conforme se incremen tó la dosis de irradiación, lo cual permitió determinar la DL 50 y RC 50 para cada especie. La media ponderada se obtuvo a los 628 Gy, 712 Gy, 698 Gy y 411 Gy para pasto llorón, buffel, banderita y navajita, respectivamente. Se recomiendan las dosis plantead as en este estudio, ya que esto permitirá plantear las bases para realizar mejoramiento genético a través de mutagénesis con irradiación gamma en los pastos evaluados.

  14. Sorption of 60 Co on inorganic solids

    International Nuclear Information System (INIS)

    Granados C, F.; Bulbulian G, S.; Mardel V, B.

    2003-01-01

    The behavior of sorption of the 60 Co in aqueous solution under static conditions to different values of pH of the aqueous solution (1, 3, 5, 7, and 10) on MgO, MnO 2 , SnO, TiO 2 , activated carbon and calcinate hydrotalcite was investigated. It was found that the best sorbents of the 60 Co was the MnO 2 , activated carbon and TiO 2 whose sorption was incremented when increasing the pH value of the aqueous solutions, in the one case of the hydrated oxides, the 60 Co interacted with the electrically charged surface of the sorbents that depends on the pH of the solution and of the point of zero charge (zpc) of the sorbent. (Author)

  15. Response of avocado genotypes to improvement through 60Co gamma radiation

    International Nuclear Information System (INIS)

    Cruz, E. De la; Rubi A, M.; Garcia A, J.M.

    1997-01-01

    Ten avocado genotypes were subjected to gamma radiation from 0 to 45 Gy in 1993. Vegetative and reproductive data were analysed in a factorial design. Genotypes differed significative on height and fruit number. Radiation affected significative fruit number but not tree height. ''Hass'' showed strongest interaction between genotype and doses, for fruit number. (Author)

  16. Ionizing radiation from {sup 60}Co and electron accelerator in reducing the population of Salmonella sp. inoculated in chicken meatballs: evaluation of acceptance by consumer;Radiacoes ionizantes provenientes de {sup 60}CO e acelerador de eletrons na reducao da populacao de Salmonella sp. inoculada em almondegas de frango: avaliacao da aceitacao do produto pelo consumidor

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Juliana

    2003-07-01

    Salmonella sp. is one of the main microorganisms that causes outbreaks of food borne diseases associated to poultry, and among its derivatives, the chicken meatballs are getting the favorites of the consumer. In the attempt to improve microbiological food safety, a method that has been hardly studied is the irradiation. To study the viability of the use o ionizing radiation originated from {sup 60} Co and electrons accelerator in the reduction of Salmonella sp., frozen chickens meatballs were inoculated with 10{sup 4} CFU/g of Salmonella sp., with needle and syringe. Subsequently they were exposure to doses of 1.5, 2.0, 2.5 and 3.0 kGy and Salmonella sp. was enumerated. Chicken meatballs were exposed to doses 3.0, 4.0 and 5.0 kGy and submitted to sensory analysis. The gamma radiation from {sup 60}CO was effective in the reduction of Salmonella sp. inoculated in chicken meatballs. The ionizing radiation originated from electron beam was not effective in the conditions applied in this research. The commercial chicken meatballs prepared with chicken meat, mixed up with soy protein, seasoning and anti-oxidants additives did not loose their sensorial quality when exposure to doses of 3.0, 4.0 and 5.0 kGy and, in a general way, the consumers showed to be disposed to buy the irradiation product (author)

  17. The relative biological effectiveness of a high energy neutron beam for micronuclei induction in T-lymphocytes of different individuals

    Energy Technology Data Exchange (ETDEWEB)

    Slabbert, J.P., E-mail: jps@tlabs.ac.z [NRF iThemba LABS (Laboratory for Accelerated Based Sciences), Somerset West (South Africa); Dept. of Medical Imaging and Clinical Oncology, University of Stellenbosch (South Africa); August, L. [NRF iThemba LABS (Laboratory for Accelerated Based Sciences), Somerset West (South Africa); Vral, A. [Dept. of Basic Medical Sciences, Ghent University (Belgium); Symons, J. [NRF iThemba LABS (Laboratory for Accelerated Based Sciences), Somerset West (South Africa)

    2010-12-15

    In assessing the radiation risk of personnel exposed to cosmic radiation fields as it pertains to radiological damage during travel in civilian aircrafts, it is particularly important to know the relative biological effectiveness (RBE) for high energy neutrons. It has been the subject of numerous investigations in recent years using different neutron energies and cytogenetic examinations. Variations in the radiosensitivity of white blood cells for different individuals are likely to influence the estimate of the relative biological effectiveness for high energy neutrons. This as such observations have been noted in the response of different cancer cell lines with varying inherent sensitivities. In this work the radiosensitivities of T-lymphocytes of different individuals to the p(66)/Be neutron beam at iThemba LABS were measured using micronuclei formations and compared to that noted following exposure to {sup 60}Co {gamma}-rays. The principle objective of this investigation was to establish if a relationship between neutron RBE and variation in biological response to {sup 60}Co {gamma}-rays for lymphocytes from different individuals could be determined. Peripheral blood samples were collected from four healthy donors and isolated lymphocytes were exposed to different doses of {sup 60}Co {gamma}-rays (1-5 Gy) and p(66)/Be neutrons (0.5-2.5 Gy). One sample per donor was not exposed to radiation and served as a control. Lymphocytes were stimulated using PHA and cultured to induce micronuclei in cytokinesis-blocked cells. Micronuclei yields were numerated using fluorescent microscopy. Radiosensitivities and RBE values were calculated from the fitted parameters describing the micronuclei frequency dose response data. Dissimilar dose response curves for different donors were observed reflecting varying inherent sensitivities to both neutron and gamma radiation. A clear reduction in the dose limiting RBE{sub M} is noted for donors with lymphocytes more sensitive to

  18. In-beam gamma spectroscopy of /sup 82/Sr

    CERN Document Server

    Dewald, A; Gelberg, A; Kaup, U; Von Brentano, P; Zell, K O

    1981-01-01

    The excited levels of /sup 82/Sr have been investigated by means of in-beam gamma-ray spectroscopy via the reactions /sup 72/Ge(/sup 12/C, 2n), /sup 66/Zn(/sup 19/F, p2n), and /sup 79/Br(/sup 6/Li, 3n). Lifetimes of excited states were measured by the recoil distance method. Excitation energies and B(E2) values have been compared with calculations using the Interacting Boson Model. (19 refs).

  19. An analytical solution to the shielding of Co 60 teletherapy rooms based on a semiempirical equation of photon attenuation

    International Nuclear Information System (INIS)

    Saez, D.G.; Hernandez, L.; Borroto, M.; Figueredo, M.

    1996-01-01

    A semiempirical equation of polynomial-exponential type is presented to describe the transmission data of Co-60 gamma radiation in finite materials of concrete and lead. This equation and the expression obtained for the relationship of scatter-to-incident exposure made easy the developing in computer of an analytical solution for shielding calculations of Co 60 teletherapy rooms, based on the procedures of the NCRP 49 and Simpkin's method. The standard error in the estimation of parameters is less than 1.7 % except for the attenuation of 150 'o' scattered radiation in concrete that resulted in 6.3 % for one of them. The shielding calculations were compared with the data in NCRP 49 for the same conditions with a correlation better than 99 %

  20. Gamma sterilization of disposable medical products (DMP's)

    International Nuclear Information System (INIS)

    Brinston, R.M.

    1990-01-01

    Ten million cubic meters (361 million cubic feet) of disposable medical products (DMP) and related health care items are estimated to be sterilized in the world. In this paper, current conditions and perspectives of gamma sterilization is discussed in comparison with ethylene oxide gas and electron beams. Of the total sterilization estimates for DMP, 2.8 million cubic meters (99 million cubic feet) are sterilized with gamma radiation, with a market share of 27%. Gamma radiation is becoming increased from both general market growth and the introduction of new products, as well as the conversion of product from ethylene oxide gas to cobalt-60. Regulatory pressures, legal considerations, and increasing publicity surrounding ethylene oxide usage are encouraging manufactures to switch to gamma radiation. Gamma's performance features include: no temperature change during the sterilization, high penetration, even through hermetically sealed packages, no residues, and no post-sterilization treatment or quarantine period. Gamma sterilization is economically beneficial in large volumes of product. Cost saving to the end user of gamma sterilization has meant lower minimum dose levels than 25 KGy. Despite of an increasingly accepted gamma radiation, there are still four factors to be considered, including cobalt-60 availability, price, transportation, and disposal. The price of cobalt-60 is based on neutron cost. In the future, cobalt-60 price is expected to be flat and enables gamma processing to become even more competitive with other sterilization methods. Gamma radiation using cobalt-60 has been proven as a safe, effective, and cost-competitive sterilization method for treating DMP and related health care items. It's wide use and many processing advantages will continue to make it a preferred sterilization method. (N.K.)

  1. Pilot postal audits in radiotherapy for 60Co in non-reference conditions in Cuba: practical consideration and preliminary results

    International Nuclear Information System (INIS)

    Gutierrez Lores, S.; Walwyn Salas, G.; Alonso Villanueva, G.

    2008-01-01

    Discusses the practical consideration and preliminary results of the Cuban's SSDL in Pilot Postal Audit in Radiotherapy for Co-60 in non-reference conditions under IAEA Coordinated Research Project E2.40.12. A strategy for national TLD audit programmes has been developed by the international Atomic Energy Agency (IAEA). It involves progression through three sequential dosimetry audit steps. The first step audits are for the beam output in reference conditions for photon beams. The second step audits are for the dose in reference and non-reference conditions on the beam axis for photon beams. The third step audits involve measurements of the dose in reference, and non-reference conditions off-axis for open and wedged symmetric and symmetric fields for photon beams. Under coordinated research project E2.40.12 were characterized 100 micro rods. All of these rods were identified individually with a consecutive number made over one of its sides, using a fine tip of graphite. The method used to determinate the individual sensibility of the TL detectors was: irradiating a group of them, with the same history of irradiation and readout. The TLD signal was read using HARSHAW 2000C/B reader. Based on the IAEA standard TLD holder for photon beams, a TLD holder was developed with horizontal arm to enable measurements 5 cm off the central axis. Successful results in two external trial carried out using the IAEA TLD service in the years 2003 - 2004 were obtained. Five 5 facilities were considered to be included in the Pilot Audit Audits in Radiotherapy for Co-60 in non reference conditions (on-axis) in the year 2003, according to recommendation of External Audit Group (EAG). For the year 2004 were considered only 3 facilities in the Pilot Audit Audits in Radiotherapy for Co-60 in non reference conditions (off-axis). Extend the postal dose audits to the rest of the institutions around the country. The participation in these audits promotes a major understanding of the physicists

  2. Activity evaluation from different native or irradiated with 60 Co gamma rays snake venoms and their inhibitory effect on Leishmania (Leishmania) amazonensis

    International Nuclear Information System (INIS)

    Lourenco, Cecilia de Oliveira

    2000-01-01

    Cutaneous leishmaniasis is a disease, caused by Leishmania parasites, that occurs frequently in tropical and sub-tropical regions of the world. Skin lesions that could results in disfiguring aspect characterize it. The treatment is based on few drugs as antimony salts or pentamidine that are toxic with increasing resistance by the parasite. Alternative forms of disease treatment are in constant search, including natural components as snake venoms. Previous studies demonstrate that some components of snake venoms have an inhibitory effect against those parasites, including Leishmania species. Although snake venoms presented high toxicity, several methods have been described to detoxify most or some of their toxic components, with favorable results by the use of gamma irradiation. In this report we tested several native and irradiated snake venoms for inhibitory effect against Leishmania (Leishmania) amazonensis parasite and LLCMK 2 mammalian cells, with enzymatic tests and electrophoresis. There are significant activity in Acanthophis antarcticus, Agkistrodon bilineatus, Bothrops moojeni, Bothrops jararaca, Hoplocephalus stephensi, Naja melanoleuca, Naja mossambica, Pseudechis australis, Pseudechis colletti, Pseudechis guttatus and Pseudechis porphyriacus, venom being inactive Pseudonaja textilis, Notechis ater niger, Notechis scutatus. Oxyuranus microlepidotus and Oxyuranus scutellatus venoms. After 2 KGy of 60 Co irradiation most venom loses significantly their activity. Venoms with antileishmanial activity presented L-amino acid oxidase (L-AO) activity and showed common protein with a molecular weight about 60kDa in SDS-PAGE. These results indicate that L-AO activity in those venoms are probably related with antileishmanial effect. (author)

  3. In vitro study of dose rate effect on Leksell Gamma Knife Perfexion

    International Nuclear Information System (INIS)

    Pastykova, V.; Novotny, J. jr.; Vachelova, J.; Davidkova, M.; Liscak, R.

    2018-01-01

    The main purpose of the study is to evaluate the radiobiological effect of the dose rate changes in Leksell Gamma Knife (LGK) clinical conditions. In principle there are two reasons why dose rate on LGK is reduced during patient irradiation: 1) Co-60 sources decay with a half-life of 5.26 years and 2) using multiple iso-centers and conformal treatment plans (e.g. with blocked beams). This pilot study is an experimental work performed in vitro with medulloblastoma DAOY cells. Are there effects caused by low dose rate which could negatively influence the clinical outcome of the radiosurgery? (authors)

  4. Transfer of 60Co from midwater squid to sperm whales

    International Nuclear Information System (INIS)

    Umezu, Takeshi; Minamisako, Yoko; Ebihara, Hiroshi; Watanabe, Hiroshi.

    1984-01-01

    Sperm whales are notable squid-eaters. They feed mainly on medium to large-sized cephalopods at midwater levels and defecate near the surface. This suggests the existence of an upward transport of 60 Co by sperm whales from the mesopelagic zone (150-1,200m). To elucidate this squid-whale route for this artificial radionuclide, 60 Co content was determined in squid and in predator whales captured by commercial whaling. In the Cephalopoda livers 60 Co levels of 30-500 mBq kg -1 wet were found and in the viscera of Odontoceti (toothed whales) 15-40 mBq kg -1 wet. About 0.3% of 60 Co ingested was estimated to be retained in a 23-year-old male sperm whale. In the livers of Bryde's whales, 60 Co levels of 40-80 mBq kg -1 wet were detected, but not in euphausiids and sardines, their possible prey. The level of Co in sperm whales was nearly the same as in Bryde's whales. Specific radioactivity 60 Co/ 59 Co in mBq μg -1 was several times higher in sperm whale (1.1-1.6) than in cephalopods (0.19-0.77). Eating prey with a high content of 60 Co in the 1960's may have contributed to the present body burden in sperm whales with a long-life span. However, the origin of 60 Co in Bryde's whales is unknown. (author)

  5. Gamma beams generation with high intensity lasers for two photon Breit-Wheeler pair production

    Science.gov (United States)

    D'Humieres, Emmanuel; Ribeyre, Xavier; Jansen, Oliver; Esnault, Leo; Jequier, Sophie; Dubois, Jean-Luc; Hulin, Sebastien; Tikhonchuk, Vladimir; Arefiev, Alex; Toncian, Toma; Sentoku, Yasuhiko

    2017-10-01

    Linear Breit-Wheeler pair creation is the lowest threshold process in photon-photon interaction, controlling the energy release in Gamma Ray Bursts and Active Galactic Nuclei, but it has never been directly observed in the laboratory. Using numerical simulations, we demonstrate the possibility to produce collimated gamma beams with high energy conversion efficiency using high intensity lasers and innovative targets. When two of these beams collide at particular angles, our analytical calculations demonstrate a beaming effect easing the detection of the pairs in the laboratory. This effect has been confirmed in photon collision simulations using a recently developed innovative algorithm. An alternative scheme using Bremsstrahlung radiation produced by next generation high repetition rate laser systems is also being explored and the results of first optimization campaigns in this regime will be presented.

  6. Studies on the transportation dynamics of 60Co in simulated ecosystem

    International Nuclear Information System (INIS)

    Wei Jianpeng; Chen Chuanqun; Wang Shouxiang; Sun Zhiming; Wang Jiyan

    1999-12-01

    The isotope tracer techniques were applied to study the transportation, accumulation and distribution of 60 Co in the pot-cultivated tomato-soil, aquatic and terrestrial ecosystems. Based on the principle of tracer dynamic compartment models, the mathematical formulae were established via computer simulation to describe the 60 Co behavior patterns in ecosystems and thus provided some basic information for elucidating the behavior of 60 Co in the environment. The results are as follows: (1) When 60 Co was introduced into the tomato-soil system, 60 Co was transported and accumulated in the soil and adsorbed by tomato root quickly, then transported to the above-ground plant. (2) The behavior patterns of 60 Co in the tomato-soil system could be described using the opened two-compartment model. (3) When 60 Co was introduced into aquatic system in the form of 60 Co-CoCl 2 , it was transported and transformed via deposit, complexation with other ions, adsorption and absorption by aquatic living things and led to the distribution and accumulation in individual part of the living things. (4) The behavior pattern of 60 Co in the aquatic-terrestrial ecosystem could be described by using opened five-compartment model

  7. Response of avocado genotypes to improvement through {sup 60}Co gamma radiation; Respuesta de diversos genotipos de aguacate al mejoramiento por radiacion gamma de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, E De la; Rubi A, M; Garcia A, J M [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    Ten avocado genotypes were subjected to gamma radiation from 0 to 45 Gy in 1993. Vegetative and reproductive data were analysed in a factorial design. Genotypes differed significative on height and fruit number. Radiation affected significative fruit number but not tree height. ''Hass'' showed strongest interaction between genotype and doses, for fruit number. (Author)

  8. Investigation of the Pygmy Dipole Resonance in {sup 60}Ni

    Energy Technology Data Exchange (ETDEWEB)

    Fritzsche, Matthias; Pietralla, Norbert; Romig, Christopher; Savran, Deniz; Sonnabend, Kerstin [Institut fuer Kernphysik, Technische Universitaet, Darmstadt (Germany); Rusev, Gencho; Tonchev, Anton P.; Tornow, Werner; Weller, Henry R. [Triangle Universities Nuclear Laboratory, Duke University, Durham, NC (United States); Zilges, Andreas [Institut fuer Kernphysik, Universitaet Koeln (Germany)

    2009-07-01

    At the High Intensity Photon Setup (HIPS) at S-DALINAC in Darmstadt {sup 60}Ni was investigated with unpolarized bremsstrahlung with energies up to 8.0 MeV and 9.9 MeV, respectively. Determination of spin and parity quantum numbers and absolute transition strengths was possible, using HPGe detectors placed under different angles. To assign also parity quantum numbers, the polarized photon beam of the High Intensity Gamma Source (HI{gamma}S) at Duke University was used. With the combined results, evidence of the Pygmy Dipole Resonance in {sup 60}Ni was found.

  9. Beam-helicity associated electroproduction of real photons ep {yields} e{gamma}{pi}N in the {Delta}-resonance region

    Energy Technology Data Exchange (ETDEWEB)

    Airapetian, A. [Giessen Univ. (Germany). 2. Physikalisches Inst.; Michigan Univ., Ann Arbor, MI (United States). Randall Laboratory of Physics; Akopov, N. [Yerevan Physics Institute (Argentina); Aschenauer, E.C. [DESY Zeuthen (Germany)] [and others; Collaboration: HERMES Collaboration

    2013-10-15

    The beam-helicity asymmetry in associated electroproduction of real photons, ep {yields} e{gamma}{pi}N, in the {Delta}(1232)-resonance region is measured using the longitudinally polarized HERA positron beam and an unpolarized hydrogen target. Azimuthal Fourier amplitudes of this asymmetry are extracted separately for two channels, ep {yields} e{gamma}{pi}{sup 0}p and ep {yields} e{gamma}{pi}{sup +}n, from a data set collected with a recoil detector. All asymmetry amplitudes are found to be consistent with zero.

  10. Comparison of proton microbeam and gamma irradiation for the radiation hardness testing of silicon PIN diodes

    Science.gov (United States)

    Jakšić, M.; Grilj, V.; Skukan, N.; Majer, M.; Jung, H. K.; Kim, J. Y.; Lee, N. H.

    2013-09-01

    Simple and cost-effective solutions using Si PIN diodes as detectors are presently utilized in various radiation-related applications in which excessive exposure to radiation degrades their charge transport properties. One of the conventional methods for the radiation hardness testing of such devices is time-consuming irradiation with electron beam or gamma-ray irradiation facilities, high-energy proton accelerators, or with neutrons from research reactors. Recently, for the purpose of radiation hardness testing, a much faster nuclear microprobe based approach utilizing proton irradiation has been developed. To compare the two different irradiation techniques, silicon PIN diodes have been irradiated with a Co-60 gamma radiation source and with a 6 MeV proton microbeam. The signal degradation in the silicon PIN diodes for both irradiation conditions has been probed by the IBIC (ion beam induced charge) technique, which can precisely monitor changes in charge collection efficiency. The results presented are reviewed on the basis of displacement damage calculations and NIEL (non-ionizing energy loss) concept.

  11. Phycoremediation of 137Cs and 60Co with selected species of aquatic microalgae

    International Nuclear Information System (INIS)

    Tatarova, D.; Galanda, D.; Strisovska, J.

    2016-01-01

    The presentation is focused on finding a suitable pH for phycoremediation of 137 Cs and 60 Co w ith microalgae Dunaliella salina and Chlorella vulgaris. To ensure a dynamic course of remediation the peristaltic pump was used, through which the solution was washed with radionuclides. During individual measurements the decrease in solution activity over time was monitored . Decline in activity in the samples was determined using a semiconductor HPGe gamma detector. The measured results showed that the best environment for phycoremediation for microalgae Dunaliella salina was at pH = 8 and less, for Chlorella vulgaris the best value was pH = 6. (authors)

  12. Calibration of the Gamma-RAy Polarimeter Experiment (GRAPE) at a polarized hard X-ray beam

    International Nuclear Information System (INIS)

    Bloser, P.F.; Legere, J.S.; McConnell, M.L.; Macri, J.R.; Bancroft, C.M.; Connor, T.P.; Ryan, J.M.

    2009-01-01

    The Gamma-RAy Polarimeter Experiment (GRAPE) is a concept for an astronomical hard X-ray Compton polarimeter operating in the 50-500 keV energy band. The instrument has been optimized for wide-field polarization measurements of transient outbursts from energetic astrophysical objects such as gamma-ray bursts and solar flares. The GRAPE instrument is composed of identical modules, each of which consists of an array of scintillator elements read out by a multi-anode photomultiplier tube (MAPMT). Incident photons Compton scatter in plastic scintillator elements and are subsequently absorbed in inorganic scintillator elements; a net polarization signal is revealed by a characteristic asymmetry in the azimuthal scattering angles. We have constructed a prototype GRAPE module containing a single CsI(Na) calorimeter element, at the center of the MAPMT, surrounded by 60 plastic elements. The prototype has been combined with custom readout electronics and software to create a complete 'engineering model' of the GRAPE instrument. This engineering model has been calibrated using a nearly 100% polarized hard X-ray beam at the Advanced Photon Source at Argonne National Laboratory. We find modulation factors of 0.46±0.06 and 0.48±0.03 at 69.5 and 129.5 keV, respectively, in good agreement with Monte Carlo simulations. In this paper we present details of the beam test, data analysis, and simulations, and discuss the implications of our results for the further development of the GRAPE concept.

  13. ADVANCED X-BAND TEST ACCELERATOR FOR HIGH BRIGHTNESS ELECTRON AND GAMMA RAY BEAMS

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, R A; Anderson, S G; Barty, C P; Chu, T S; Ebbers, C A; Gibson, D J; Hartemann, F V; Adolphsen, C; Jongewaard, E N; Raubenheimer, T; Tantawi, S G; Vlieks, A E; Wang, J W

    2010-05-12

    In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

  14. Response of avocado genotypes to improvement through {sup 60}Co gamma radiation; Respuesta de diversos genotipos de aguacate al mejoramiento por radiacion gamma de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, E. De la; Rubi A, M.; Garcia A, J.M. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    Ten avocado genotypes were subjected to gamma radiation from 0 to 45 Gy in 1993. Vegetative and reproductive data were analysed in a factorial design. Genotypes differed significative on height and fruit number. Radiation affected significative fruit number but not tree height. ''Hass'' showed strongest interaction between genotype and doses, for fruit number. (Author)

  15. Reliability studies on Si PIN photodiodes under Co-60 gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakara Rao, Y. P. [Integrated Circuits Division, Bharat Electronics Limited, Bangalore, Karnataka-560013 (India) and Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore, Karnataka-570006 (India); Praveen, K. C.; Gnana Prakash, A. P. [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore, Karnataka-570006 (India); Rani, Y. Rejeena [Integrated Circuits Division, Bharat Electronics Limited, Bangalore, Karnataka-560013 (India)

    2013-02-05

    Silicon PIN photodiodes were fabricated with 250 nm SiO{sub 2} antireflective coating (ARC). The changes in the electrical characteristics, capacitance-voltage characteristics and spectral response after gamma irradiation are systematically studied to estimate the radiation tolerance up to 10 Mrad. The different characteristics studied in this investigation demonstrate that Si PIN photodiodes are suitable for high radiation environment.

  16. Effect of antioxidants on thiobarbituric acid reactive substances, psychrotrophic bacteria and functional properties of mechanically deboned chicken meat irradiated with Cobalto-60 and electron beam sources

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Pomarico Neto, Walter, E-mail: hgomes@cnen.gov.br, E-mail: pbrito@cnen.gov.br, E-mail: cvroque@cnen.gov.br, E-mail: abrusqui@cnen.gov.br [Comissao Nacional de Energia Nuclear (LAPOC/CNEN-MG), Pocos de Caldas, MG (Brazil). Laboratorio de Pocos de Caldas; Mourao, Gerson Barreto; Orlando, Eduardo Adilson; Miyagusku, Luciana, E-mail: marciamh@ital.sp.gov.br, E-mail: eduardo.orlando@ital.sp.gov.br [Instituto de Tecnologia dos Alimentos (ITAL), Campinas, SP (Brazil)

    2013-07-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 (Sodium Polyphosphate and Sodium Ascorbate and Antioxidant 2 (Rosemary Extract and α-Tocopherol. The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (C), with antioxidant A1 and non-irradiated (A1), with antioxidant A2 and non-irradiated (A2) without antioxidant and irradiated in Cobalt-60 source (Co), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). The samples was conditioned in a transparent, low density frozen overnight at a temperature of -18 ± 1 deg C in a chamber, and irradiated in this state with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy/h) and electron beam (7.86 kGy/s). After this process, the samples were evaluated during the refrigeration period (2 ± 1 deg C) for 11 days for the following analysis: total psychrotrophic bacteria count and thiobarbituric acid reactive substances (TBARS) and the analysis of functional properties were performed after the irradiation process. The use of the combination of rosemary antioxidant and α-tocopherol were able to significantly decrease TBARS values caused by the irradiation of samples in MDCM cobalt-60 sources and electron beam, and show a synergetic effect to processing with ionizing radiation to reduce of psychrotrophic bacteria count. The use of irradiation processing of MDCM did not negatively affect the functional properties studied. (author)

  17. Effect of antioxidants on thiobarbituric acid reactive substances, psychrotrophic bacteria and functional properties of mechanically deboned chicken meat irradiated with Cobalto-60 and electron beam sources

    International Nuclear Information System (INIS)

    Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Pomarico Neto, Walter

    2013-01-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 (Sodium Polyphosphate and Sodium Ascorbate and Antioxidant 2 (Rosemary Extract and α-Tocopherol. The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (C), with antioxidant A1 and non-irradiated (A1), with antioxidant A2 and non-irradiated (A2) without antioxidant and irradiated in Cobalt-60 source (Co), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). The samples was conditioned in a transparent, low density frozen overnight at a temperature of -18 ± 1 deg C in a chamber, and irradiated in this state with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy/h) and electron beam (7.86 kGy/s). After this process, the samples were evaluated during the refrigeration period (2 ± 1 deg C) for 11 days for the following analysis: total psychrotrophic bacteria count and thiobarbituric acid reactive substances (TBARS) and the analysis of functional properties were performed after the irradiation process. The use of the combination of rosemary antioxidant and α-tocopherol were able to significantly decrease TBARS values caused by the irradiation of samples in MDCM cobalt-60 sources and electron beam, and show a synergetic effect to processing with ionizing radiation to reduce of psychrotrophic bacteria count. The use of irradiation processing of MDCM did not negatively affect the functional properties studied. (author)

  18. Determination of the displacement cross-section in C-60 fullerene exposed to the gamma rays

    International Nuclear Information System (INIS)

    Leyva, A.; Pinnera, I.; Leyva, D.; Cruz, C.; Abreu, Y.

    2011-01-01

    Using the threshold energy values reported in literature for spherical fullerene C-60 molecules and taking into account the McKinley-Feshbach approach, the effective atomic displacement cross-section in C-60 nanostructures exposed to the gamma rays was estimated. The Kinchin-Pease approximation for the damage function was also considered. These calculations were performed using MCCM code system developed by the authors for the study of gamma radiation damage in solid materials. (Author)

  19. Effects of 60Co gamma radiation on Biomphalaria glabrata (Say, 1818) Embryo, I. Mortality

    International Nuclear Information System (INIS)

    Okazaki, K.; Kawano, T.

    1990-01-01

    A study was conducted on the radiosensitivity of Biomphalaria glabrata embryos submitted to doses of 5, 10,15,20 and 25 Gy of 60 Co during the cleavage, blastula, gastrula, young trochophore and trochophore stages. Mortality was the parameter used to evaluated the damage induced by ionizing radiation. Susceptibility decreased with increasing embryo age and with decreased radiation dose. Estimated LD 50 values (15 days) showed that the cleavage stage (4.3 Gy) was approximately four times more radiosensitive than the trochophore stage (17.0 Gy). The survival curves obtained for each embryo stage are discussed on the basis of the multitarget theory. (author) [pt

  20. Desulfurization of petroleum by Co-60 gamma irradiation and analysis of products using GC-MS

    International Nuclear Information System (INIS)

    Mathuthu, M.; Tshivhase, V.M.; Olobatoke, R.Y.; Gaxela, N.N.

    2014-01-01

    Sulfur is an undesirable hetero-atom that has negative on motor engines if present in quantities between 50 and 180.000 ppm. Research has shown that sour petroleum can be 'sweetened' by gamma irradiation to de-sulfurize the crude oil. In this research we will report experimental results of desulfurizing petroleum locally procured. The objective is to improve the quality of product delivered to the motor market and also reduce the environmental pollution due to SO 2 emissions from engines. The gamma irradiated (de-sulfurized petroleum was chemically analyzed using GC-MS. The preliminary results show that the petroleum is polymerized by gamma radiation to higher molecular mass. The un-irradiated petroleum had a sulfur concentration of 3.24% and 0.020% wt after gamma irradiation. The sulfur content was reduced by a factor of about 160 when dose was increased from zero to 50 kGys. GC-MS Chromatographs are presented for the identified hydrocarbons after gamma irradiation. (authors)

  1. Co-60 uptake in some young cereal plants

    International Nuclear Information System (INIS)

    Dumitru, R.O.

    1998-01-01

    The measure of Co-60 uptake by young cereal plants is dependent on the type of soil, plant and growth conditions. Depending on the size of the uptake, a plant can be used for industrial purposes, fodder, foodstuff or for possible decontamination of the soil. Although the requirement for cobalt in higher plants is little, their contamination with Co-60 can be of interest because this radionuclide belongs to the class of the radionuclides with a great radiotoxicity. The soil-to-plant transfer factor (TF) is a measure of the radionuclide uptake in the plant. In this paper the soil-to-plant TFs for Co-60 were determined for the whole aerial part of some young plants in the cereal class that, in this stage of the development, may be used as fodder. To determine soil-to-plant TFs, plants cultivated in pots in laboratory conditions were used. The method used is similar with the plantlet method of Neubauer and Schneider. We have determined some physical, chemical and mineralogical properties of the studied soil, a brown-reddish forest type soil. The soil-to-plant TFs were calculated on the basis of the Co-60 activities determined in plant and soil dried samples. For the vegetal samples the whole aerial part of the plants was measured in millet, wheat, barley and triticale. At harvest, only a few millet plants where flowered. The results of the measurements of soil-to-plant TFs of Co-60 are the following: 0.0315±0.0017 for millet, 0.0260±0.0014 for barley, 0.0140±0.0008 for wheat and 0.0491±0.0022 for triticale. These TFs were corrected for standard conditions and were compared with data from literature. The soil-to-plant TFs for Co-60 found in the aerial part of young cereals are close to those recommended for the fodder. The obtained values prove the strong dependence of the soil-to-plant TFs for Co-60 on the type of soil and plant. (author)

  2. Flame retardant cotton fabrics by electron beam-induced polymerization of vinyl phosphonate oligomer

    International Nuclear Information System (INIS)

    Sawai, Takeshi; Ametani, Kazuo; Enomoto, Ichiro

    1988-01-01

    Vinyl phosphonate oligomer is presently used commercially as a cellulosic flame retardant in conjugation with N-methylol acrylamide, using a persulfate catalyst and a thermal cure. This combination can also be cured at room temperature with electron beams, as can the vinyl phosphonate alone. For the textile application, fixation of flame retardants by electron beams with low energy is one of the most promising applications. For the purpose of preparing flame resistant cotton fabrics such as bed sheets and pajamas, flame retardant curing of vinyl phosphonate oligomer on cotton fabrics was examined using electron beams from a self-sealed electron beam processor and gamma rays from a 60 Co source. A joint investigation was undertaken by the Tokyo Metropolitan Textile Research Institute and Tokyo Metropolitan Isotope Research Center to determine the feasibility of curing vinyl phosphonate oligomer on the cotton fabrics for textile finishing. (author)

  3. Beam dynamics in Compton ring gamma sources

    Directory of Open Access Journals (Sweden)

    Eugene Bulyak

    2006-09-01

    Full Text Available Electron storage rings of GeV energy with laser pulse stacking cavities are promising intense sources of polarized hard photons which, via pair production, can be used to generate polarized positron beams. In this paper, the dynamics of electron bunches circulating in a storage ring and interacting with high-power laser pulses is studied both analytically and by simulation. Both the common features and the differences in the behavior of bunches interacting with an extremely high power laser pulse and with a moderate pulse are discussed. Also considerations on particular lattice designs for Compton gamma rings are presented.

  4. Cobalt-60 gamma irradiation of shrimp

    International Nuclear Information System (INIS)

    Sullivan, N.L.B.

    1993-01-01

    Meta- and ortho-tyrosine were measured using high performance liquid chromatography (HPLC) in conjunction with electrochemical detection in shrimp irradiated using cobalt-60 gamma radiation in the absorbed dose range 0.8 to 6.0 kGy, in nonirradiated shrimp, and in bovine serum albumin (BSA) irradiated in dilute aqueous solution at 25.0 kGy. Ortho-tyrosine was measured in nonirradiated BSA. Para-, meta-, and ortho-tyrosine was measured using HPLC in conjunction with uv-absorption detection in dilute aqueous solutions of phenylalanine irradiated in the absorbed dose range 16.0 to 195.0 kGy. The measured yields of tyrosine isomers were approximately linear as a function of absorbed dose in shrimp, and in irradiated solutions of phenylalanine up to 37.0 kGy. The occurrence of meta- and ortho-tyrosine, which had formerly been considered unique radiolytic products, has not previously been reported in nonirradiated shrimp or BSA. The conventional hydrolyzation and analytical techniques used in the present study to measure meta- and ortho-tyrosine may provide the basis for a method to detect and determine the dose used in food irradiation

  5. Neutron/gamma dose separation by the multiple-ion-chamber technique

    International Nuclear Information System (INIS)

    Goetsch, S.J.

    1983-01-01

    Many mixed n/γ dosimetry systems rely on two dosimeters, one composed of a tissue-equivalent material and the other made from a non-hydrogenous material. The paired chamber technique works well in fields of neutron radiation nearly identical in spectral composition to that in which the dosimeters were calibrated. However, this technique is drastically compromised in phantom due to the degradation of the neutron spectrum. The three-dosimeter technique allows for the fall-off in neutron sensitivity of the two non-hydrogenous dosimeters. Precise and physically meaningful results were obtained with this technique with a D-T source in air and in phantom and with simultaneous D-T neutron and 60 Co gamma ray irradiation in air. The MORSE-CG coupled n/γ three-dimensional Monte Carlo code was employed to calculate neutron and gamma doses in a water phantom. Gamma doses calculated in phantom with this code were generally lower than corresponding ion chamber measurements. This can be explained by the departure of irradiation conditions from ideal narrow-beam geometry. 97 references

  6. V79 survival following simultaneous or sequential irradiation by 15-MeV neutrons and 60Co photons

    International Nuclear Information System (INIS)

    Higgins, P.D.; DeLuca, P.M. Jr.; Pearson, D.W.; Gould, M.N.

    1983-01-01

    A unique tandem source irradiation facility, composed of an intense d-T neutron source and a 60 Co teletherapy unit, was used to investigate biological responses for different neutron/photon configurations. V79 Chinese hamster cells, attached as monolayers in log-phase growth, were irradiated at 37 degrees C by either 14.8-MeV neutrons, 60 Co, or a mixture of 40% neutrons and 60% photons in simultaneous or sequential application. Measurements of cell survival indicate an increased effectiveness in cell killing for simultaneously administered neutrons and photons compared to that measured or predicted for sequentially applied beam modalities. An understanding of the magnitude of these interactive effects is important both for calculating accurate effective doses for neutron radiotherapy of deep-seated tumors, for which the photon component is appreciable, and for determination of environmental hazards to people occupationally exposed to mixtures of photons and neutrons

  7. V79 survival following simultaneous or sequential irradiation by 15-MeV neutrons and 60Co photons

    International Nuclear Information System (INIS)

    Higgins, P.D.; DeLuca, P.M. Jr.; Pearson, D.W.; Gould, M.N.

    1983-01-01

    A unique tandem source irradiation facility, composed of an intense d-T neutron source and a 60 Co teletherapy unit, was used to investigate biological responses for different neutron/photon configurations. V79 Chinese hamster cells, attached as monolayers in log-phase growth, were irradiated at 37 0 C by either 14.8-MeV neutrons, 60 Co, or a mixture of 40% neutrons and 60% photons in simultaneous or sequential application. Measurements of cell survival indicate an increased effectiveness in cell killing for simultaneously administered neutrons and photons compared to that measured or predicted for sequentially applied beam modalities. An understanding of the magnitude of these interactive effects is important both for calculating accurate effective doses for neutron radiotherapy of deep-seated tumors, for which the photon component is appreciable, and for determination of environmental hazards to people occupationally exposed to mixtures of photons and neutrons

  8. DNA damage and γH2AX expression in EJ cells induced by 60Co gamma-rays

    International Nuclear Information System (INIS)

    Pan Yan; Tian Mei; Liu Jianxiang; Ruan Jianlei; Su Xu

    2009-01-01

    Objective: To investigate 60 Co γ-rays induced DNA damage of human bladder cancer cell line EJ cells and the relationship between different doses of 60 Co γ-rays, γH2AX foci number and γH2AX expression level. Methods: EJ cells were exposed to different doses of 60 Co γ-rays and the oliver tail moment (TM) of EJ cells were analyzed with single cell gel electrophoresis (SCGE) . Immunofluorescent microscopy was used to analysis γH2AX foci formation in EJ cells after exposure to different doses of γ-ray irradiation and time-course after exposure to 2 Gy γ-ray irradiation. FACSAria was used to detect the changes of γH2AX protein expression in EJ cells. Results: The TMs of EJ cells were increased with the irradiation dose. The TM of 0 Gy group and 4 Gy group was 0.24 and 5.26, respectively. Immunofluorescent analysis demonstrated that γH2AX foci could be induced by γ-ray irradiation in dose-dependent and time-dependent manners. The foci number and size in nuclei of EJ cells was significantly increased after exposed to different doses of γ-ray irradiation and the foci remained detectable at 24 h after exposed to irradiation. The dose range in which foci could be clearly detected was from 0.1 to 4 Gy. FACSDiva showed that γH2AX protein expression was increased after exposure to different doses of γ-ray irradiation. γH2AX protein expression level of 0.1 Gy group and 4 Gy group was 7.4% and 29.2% , respectively. Conclusions: γH2AX foci could be the most sensitive indicator for DNA damage and repair in mammalian cells, and it might be a new biomarker for radiological emergency. (authors)

  9. Absolute exposure determination of cobalt-60 gamma radiation

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Ali, A.; Orfi, S.D.

    1986-02-01

    The report describes the procedure for the determination of absolute exposure for Cobalt-60 gamma radiation. A graphite cavity chamber, nominal volume of 1 cm 3 , manufactured by Austrian Research Centre Seibersdorf has been used. The exposure rate at reference distance determined with the graphite chamber was compared with mean exposure rate measured with NPL-Therapy level X-ray exposure meter normalized to same date. An agreement of 0.39% was found between the two measuring systems, which seems to be very encouraging and quite satisfactory. (authors)

  10. Optimization of point sources on thin films using a statistical design approach. Application to {sup 60}Co sources; Optimisation des sources ponctuelles sur film mince par une approche experimentale de type plan d'experiences. Application aux sources de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Sanoit, J.; Leprince, B. [CEA Saclay, Dept. d' Instrumentation et de Metrologie des Rayonnements Ionisants, 91 - Gif sur Yvette (France); Vailhen, D. [CEA Saclay, Dir. de la Surete Nucleaire et de la Qualite, 91 - Gif sur Yvette (France)

    2001-07-01

    Radioactive point sources prepared by depositing weighed drops on thin membranes are commonly used in ionizing radiation metrology for 47{pi}{beta}-{gamma} coincidence counting or for low energy electrons spectrometry. The present study deals with the preparation of good quality sources having high detection yields. Some influential parameters on the source quality are studied using {sup 60}Co as radioactive tracer. An approach based on experimental statistical designs has been chosen. This approach allows us to obtain reliable results with a number of experiences lower than in the case of a systematic approach. Homogeneous {sup 60}Co sources with high metrological qualifies (R{sub {beta}}> 96 %) can be prepared using a direct deposit of {approx} 5 mg drops of {sup 60}Co solution ([Co] = 12 {mu}g/g, [HCl] = 0,5 mol/I) and dried at 60 deg C. The support of the radioactive spot is constituted with a gold coated (130 {mu}g/cm{sup 2} of Au) Vyns films (thickness 45 {mu}g/cm{sup 2}) on which a pad (diameter = 7 - 8 mm) of polystyrene microspheres (Estapor K-007) is prepared by an electro-spraying technique under 7,5 kV during 10 minutes. The alcoholic solution used for the electro-spraying step has the following chemical composition [Estapor K-007] 2.5 10{sup -2} wt % and [Tween 20] = 2.7 10{sup -2} wt %. (authors)

  11. Feasibility study on production of Co-60 in PHWR

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Bae; Han, Hyon Soo; Joo, Po Kook

    2000-05-01

    The purpose of this study is to analyze the safeties and the economics for Co-60 production from Wolsung PHWR and to verify the feasibility on the manufacturing of the final Co-60 source for industrial irradiation. The feasibility of reactor conversion was carried out with KEPCO collaboration. Through the site survey on the experience of Gentililly-2 in Canada, a feasibility of plant conversion, changes in design, equipment and tools for Co-60 production was verified. It was estimated that the reactor conversion would not impose adverse impact on plant safety. For the encapsulation of radiation source and storage of the final products, a modification of concrete hot cell at KAERI was primary concerns. The installation and improvement of facilities are needed to avoid cross contamination and extra radiation exposure. Main items for these are pressure gauge, separated HEPA filter the ceiling separation, extra-shielding and ceiling hoist system. At present, storage pool has got admission based on 400 kCi. But it is necessary to seismic analysis and design improvement of shielding to store 10 MCi (Co-60) which is the estimated Co-60 capacity produced by 3 PHWRs. According to present investigation, a production of Co-60 by PHWR and RIPE was seemed to be an economically feasible business and it was also expected that a joint venture will be able to realize by cooperation with MDS Nordion Co.

  12. Feasibility study on production of Co-60 in PHWR

    International Nuclear Information System (INIS)

    Park, Kyung Bae; Han, Hyon Soo; Joo, Po Kook

    2000-05-01

    The purpose of this study is to analyze the safeties and the economics for Co-60 production from Wolsung PHWR and to verify the feasibility on the manufacturing of the final Co-60 source for industrial irradiation. The feasibility of reactor conversion was carried out with KEPCO collaboration. Through the site survey on the experience of Gentililly-2 in Canada, a feasibility of plant conversion, changes in design, equipment and tools for Co-60 production was verified. It was estimated that the reactor conversion would not impose adverse impact on plant safety. For the encapsulation of radiation source and storage of the final products, a modification of concrete hot cell at KAERI was primary concerns. The installation and improvement of facilities are needed to avoid cross contamination and extra radiation exposure. Main items for these are pressure gauge, separated HEPA filter the ceiling separation, extra-shielding and ceiling hoist system. At present, storage pool has got admission based on 400 kCi. But it is necessary to seismic analysis and design improvement of shielding to store 10 MCi (Co-60) which is the estimated Co-60 capacity produced by 3 PHWRs. According to present investigation, a production of Co-60 by PHWR and RIPE was seemed to be an economically feasible business and it was also expected that a joint venture will be able to realize by cooperation with MDS Nordion Co

  13. Development of Irradiation Procedure for Gamma Irradiation Chamber Bio beam GM 8000

    International Nuclear Information System (INIS)

    Shuhaimi Shamsudin; Affrida Abu Hassan; Zaiton Ahmad; Abdul Rahim Harun; Ahmad Zainuri Mohd Dzomir

    2015-01-01

    Bio Beam GM 8000 gamma irradiation chamber obtained a conditional approval to operate on March 27, 2012, and later acquired a full approval on December 13, 2012. The objective for the procurement of this gamma chamber is to develop an acute irradiation facility for biological samples, including plants tissues, insects, pupae, microorganisms, as well as animal and human cells. To ensure a smooth and efficient operation, irradiation procedures were developed and improved over time. This paper discusses the operation and management of the Bio Beam GM 8000 facility, including irradiation procedures and sample preparation, application for services through online e-client system, consultancy, quality assurance and information dissemination to internal as well as external clients. In addition, this paper also discusses the potential, constraints and improvement measures taken to optimize the use of this facility in order to meet its objectives. (author)

  14. Effect of pulsed dose in simultaneous and sequential irradiation of V-79 cells by 14.8 MeV neutrons and 60Co photons

    International Nuclear Information System (INIS)

    Higgins, P.D.; DeLuca, P.M. Jr.; Gould, M.N.; Schell, M.C.; Pearson, D.W.

    1983-01-01

    The effect of irradiating V-79 Chinese hamster ovary cells with a mixture of 40% 14.8-MeV neutrons and 60% 60 Co photons with simultaneous or sequential exposures is investigated. Target doses are obtained by irradiating cell samples with 3-minute-long pulses of alternating neutrons and photons (in the sequential case) or with mixed neutrons and photons followed by equal beam-off periods to insure equal total-exposure times for sequenced and simultaneous irradiations. We observe qualitative differences between the survival results under each beam configuration that confirms earlier observations

  15. A response of L-α-alanine and standard bone powder on 3.4 MeV/amu 59Co ion beams

    International Nuclear Information System (INIS)

    Stuglik, Z.; Sadlo, J.

    1997-01-01

    Dosimetric response of microcrystaline L-α-alanine and standard bovine bone powder on 3.4 MeV/amu 59 Co ions (LET ∼5500 eV/nm) was investigated. The long-lived paramagnetic centers created by ion beams were measured after 51 and 420 days. Relative sensitivity compared to gamma rays was estimated at 0.2 for L-α-alanine and 0.15 for standard bovine bone powder. (Author)

  16. Activation measurements for thermal neutrons. Part A. Cobalt (60Co) activation

    International Nuclear Information System (INIS)

    Kerr, George D.; Shizuma, Kiyoshi; Endo, Satoru; Maruyama, Takashi; Cullings, Harry M.; Komura, Kazuhisa; Okumura, Yutaka; Egbert, Stephen D.

    2005-01-01

    The 60 Co measurements at Hiroshima and Nagasaki were reviewed and compared with the results of the new DS02 calculations for the two cities. Some corrections were made to previously published data from the 1965 measurements of JNIRS, ground ranges of all of the 60 Co measurements were reviewed and new ground ranges were determined when possible by transforming sample coordinates to the new city maps for Hiroshima and Nagasaki, and transmission factors were investigated for a number of samples used in the 60 Co measurements. Transmission factors were not calculated for all samples used in the 60 Co measurements but some general rules were given for estimating transmission factors for these samples. Experimental measurements of the background 60 Co activity from environmental neutrons were also reviewed, and it was found that the 60 Co background from environmental neutrons was not an important factor in the 60 Co measurements of bomb-induced activity at either city. (J.P.N.)

  17. Induction of mutation, through gamma rays, in sugarcane

    International Nuclear Information System (INIS)

    Vieira, M.A.S.; Matsuoka, S.; Ruschel, R.

    1984-01-01

    Variety buds Co-740 of sugar cane were irradiated with gamma rays 60 Co at 0.0, 3.0, 4.0, 5.0, 6.0 and 7.0 kR to study changes in the obtained progeny. Evaluation of the germination capacity, height of plants and morphological changes were studied in the different treatments. (M.A.C.) [pt

  18. YAP(Ce) crystal characterization with proton beam up to 60 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Randazzo, N. [Istituto Nazionale di Fisica Nucleare, Sezione di Catania (I), Via S. Sofia, 64-I-95123 Catania (Italy)], E-mail: nunzio.randazzo@ct.infn.it; Sipala, V.; Aiello, S. [Istituto Nazionale di Fisica Nucleare, Sezione di Catania (I), Via S. Sofia, 64-I-95123 Catania (Italy); Lo Presti, D. [Istituto Nazionale di Fisica Nucleare, Sezione di Catania (I), Via S. Sofia, 64-I-95123 Catania (Italy); Dipartimento di Fisica e Astronomia, Universita di Catania, Catania (Italy); Cirrone, G.A.P.; Cuttone, G.; Di Rosa, F. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud (Italy)

    2008-02-21

    A YAP(Ce) crystal was characterized with a proton beam up to 60 MeV. Tests were performed to investigate the possibility of using this detector as a proton calorimeter. The size of the crystal was chosen so that the proton energy is totally lost inside the medium. The authors propose to use the YAP(Ce) crystal in medical applications for proton therapy. In particular, in proton computed tomography (pCT) project it is necessary as a calorimeter in order to measure the proton residual energy after the phantom. Energy resolution, linearity, and light yield were measured in the Laboratori Nazionali del Sud with the CATANA proton beam [ (http://www.lns.infn.it/CATANA/CATANA)] and the results are shown in this paper. The crystal shows a good resolution (3% at 60 MeV proton beam) and it shows good linearity for different proton beam energies (1% at 30-60 MeV energy range). The crystal performances confirm that the YAP(Ce) crystal represents a good solution for these kinds of application.

  19. YAP(Ce) crystal characterization with proton beam up to 60 MeV

    International Nuclear Information System (INIS)

    Randazzo, N.; Sipala, V.; Aiello, S.; Lo Presti, D.; Cirrone, G.A.P.; Cuttone, G.; Di Rosa, F.

    2008-01-01

    A YAP(Ce) crystal was characterized with a proton beam up to 60 MeV. Tests were performed to investigate the possibility of using this detector as a proton calorimeter. The size of the crystal was chosen so that the proton energy is totally lost inside the medium. The authors propose to use the YAP(Ce) crystal in medical applications for proton therapy. In particular, in proton computed tomography (pCT) project it is necessary as a calorimeter in order to measure the proton residual energy after the phantom. Energy resolution, linearity, and light yield were measured in the Laboratori Nazionali del Sud with the CATANA proton beam [ (http://www.lns.infn.it/CATANA/CATANA)] and the results are shown in this paper. The crystal shows a good resolution (3% at 60 MeV proton beam) and it shows good linearity for different proton beam energies (1% at 30-60 MeV energy range). The crystal performances confirm that the YAP(Ce) crystal represents a good solution for these kinds of application

  20. YAP(Ce) crystal characterization with proton beam up to 60 MeV

    Science.gov (United States)

    Randazzo, N.; Sipala, V.; Aiello, S.; Lo Presti, D.; Cirrone, G. A. P.; Cuttone, G.; Di Rosa, F.

    2008-02-01

    A YAP(Ce) crystal was characterized with a proton beam up to 60 MeV. Tests were performed to investigate the possibility of using this detector as a proton calorimeter. The size of the crystal was chosen so that the proton energy is totally lost inside the medium. The authors propose to use the YAP(Ce) crystal in medical applications for proton therapy. In particular, in proton computed tomography (pCT) project it is necessary as a calorimeter in order to measure the proton residual energy after the phantom. Energy resolution, linearity, and light yield were measured in the Laboratori Nazionali del Sud with the CATANA proton beam [ http://www.lns.infn.it/CATANA/CATANA] and the results are shown in this paper. The crystal shows a good resolution (3% at 60 MeV proton beam) and it shows good linearity for different proton beam energies (1% at 30-60 MeV energy range). The crystal performances confirm that the YAP(Ce) crystal represents a good solution for these kinds of application.

  1. Evaluation of skyshine dose due to gamma-rays from a cobalt-60 irradiation facility

    International Nuclear Information System (INIS)

    Kanazawa, Tamotsu; Okamoto, Shinichi; Ohnishi, Tokuhiro; Tsujii, Yukio

    1991-01-01

    We attempted to evaluate skyshine dose due to gamma-rays from a cobalt-60 irradiation facility. As the first step, the results of measurements and calculations were compared of the skyshine dose due to gamma-rays from the cobalt-60 source of 1.45 PBq set in the No.4 irradiation room of our laboratory. Distances of measuring points from the cobalt source were in the range from 17 m to about 100 m in the site of our office. Calculation was carried out with simplified single scattering method. The calculated values of the skyshine dose were higher than the measured values. For more precise evaluation of the skyshine dose, the following factors are to be considered; the dose rate distribution on the roof above the source and the attenuation of gamma-rays by air. (author)

  2. Analysis of the frequency of unstable chromosome aberrations in human lymphocytes irradiated with {sup 60}Co; Analise da frequencia de alteracoes cromossomicas instaveis em linfocitos humanos irradiados com {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Mendonca, Julyanne C.G.; Mendes, Mariana E.; Lima, Fabiana F., E-mail: july_cgm@hotmail.com, E-mail: mendes_sb@hotmail.com [Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Santos, Neide, E-mail: santos_neide@yahoo.com.br [Universidade Federal de Pernambuco (CCB/UFPE), Recife, PE (Brazil). Departamento de Genetica

    2013-07-01

    The aim of this study was to analyze the frequency of unstable chromosomal aberrations induced by gamma radiation from a {sup 60}Co source at two different doses. Samples were obtained from a healthy donor and exposed to {sup 60}Co source (Gammacel 220 ) located in the Department of Nuclear Energy of Pernambuco Federal University (DEN/UFPe/Brazil) with a rate of air Kerma to 3,277 Gy/h. Exposures resulted in absorbed dose 0.51 Gy and 0.77 Gy. Mitotic metaphases were obtained by culturing lymphocytes for chromosome analysis and the slides were stained with 5% Giemsa. Among the unstable chromosomal aberrations the dicentric chromosomes, ring chromosomes and acentric fragments were analyzed. To calculate the significance level the chi - square test was used, considering relevant differences between the frequencies when the value of p < 0.05. To calculate the significance level of the chi - square test was used, considering relevant differences between the frequencies when the value of p < 0.05. The results showed that there was significant difference of the frequencies of dicentric chromosomes (from 0.18 to 0.51 to 0.37 Gy to 0.77 Gy), however there was no statistically significant difference between the frequencies of acentric fragments ( 0.054 to 0, 51 Gy to 0.063 to 0.77 Gy) and ring chromosomes (0.001 to 0.51 Gy to 0.003 to 0.77 Gy). The low number of rings is found justified, considering that in irradiated human lymphocytes, its appearance is rare relative to dicentrics. The results confirm that dicentrics are the most reliable biomarkers in estimating dose after exposure to gamma radiation. These two points will make the calibration curve dose-response being built for Biological Dosimetry Laboratory of CRCN-NE/CNEN.

  3. Assessment of dose load of personnel in intratissue gamma beam therapy

    International Nuclear Information System (INIS)

    Stavitskij, R.V.; Zamyatin, O.A.; Varennikov, O.I.; Astakhova, I.V.

    1995-01-01

    Suggest a method for retrospective assessment of levels of irradiation of small groups of personnel exposed to radiation sources. Presents estimated values of cumulative and local doses obtained by personnel during intratissue gamma beam therapy carried out by manual consecutive injections of intrastats and irradiation sources. 3 refs.; 5 tabs

  4. Measurement of Relative Biological Effectiveness (RBE) for the Radiation Beam from Neutron Source Reactor YAYOI -Comparisons with Cyclotron Neutron and 60Co Gamma Ray-

    OpenAIRE

    HIROAKI, WAKABAYASHI; SHOZO, SUZUKI; AKIRA, ITO; Nuclear Engineering Research Laboratory, Faculty of Engineering, the University of Tokyo; Institute of Medical Science, the University of Tokyo; Institute of Medical Science, the University of Tokyo

    1983-01-01

    Radiation biology and/or therapy research and development for a research reactor beam need specific RBEs of neutrons as well as of specific reactions. RBEs for reactor beams measured in situ condition are interesting because actual radiation effects on each biological system are different depending on detailed conditions of irradiation. A small powered research reactor (Fast Neutron Source Reactor: YAYOI) was examined here as a neutron beam source for obtaining survival curves in a manner usu...

  5. Modeling of 60Co transport by groundwater

    International Nuclear Information System (INIS)

    Serebryakov, B.E.; Ivanov, E.A.; Shchukin, A.P.

    2006-01-01

    Results of calculation of the 60 Co migration in a water-bearing horizon after the accident Novo-Voronezh NPP in 1985 are presented. The accident was connected with the liquid radioactive waste leakage into the ground water. The features of 60 Co migration in the water-bearing horizon and its coming into the Don river are calculated by means of three-dimensional models. Population irradiation estimations show that the accident did not lead to exceeding the recommended dose limits [ru

  6. Beam pulsing of C60 electrostatic injector accelerator for linac

    International Nuclear Information System (INIS)

    Takahashi, Y.; Hattori, T.; Kashiwagi, H.; Hata, T.; Noda, K.

    2000-01-01

    The research which measured the energy loss by the interaction between C 60 fullerene beam and solid film using the TOF method was started. The beam pulsing equipment was manufactured in this reason. The method by the copping was adopted for the pulsing, and 10 kHz high frequency was applied between electrodes, and the 20 V maximum voltage between electrodes was obtained. The 600 keV acceleration will be carried out by the 200 kV accelerating column, after pulsing is sent to C 60 fullerene beam drawn from electron impact type ion source at 300 V in pulse intervals 50 μs and 4.6 μs pulse width. The APF-IH type linear accelerator that it settles the fullerene more and more using the APF focusing and accelerates at the high acceleration is designed and is manufactured, and this is made to be a linear accelerator of back step, the high energy acceleration will be carried out. (author)

  7. Long-term follow-up after accidental gamma irradiation from a 60Co source

    International Nuclear Information System (INIS)

    Klener, V.; Tuscany, R.; Vejlupkova, J.; Dvorak, J.; Vlkovic, P.

    1986-01-01

    In December 1973 a technician was accidentally irradiated when attempting to bring under control a sealed 60 Co source (110 TBq) which had been lodged in the head of a medical irradiation unit during a replacement operation. In the early period after the accident, severe skin changes on the left hand, epilation in a small area of the left temporal region and minor deviations in peripheral blood developed. In the following years, repeated surgery due to secondary skin defects of the left hand resulted in the loss of the fingers 2-5. Since 1975, changes in the lens of the left eye began to appear leading gradually to the deterioration of visual acuity. Later, opacities of the lens of the right eye were found. The patient's psychological and emotional attitude about the accident changed in the course of time. The factors influencing the psychic state of the patient are identified

  8. Assessment of shielding integrity of Co-60 gamma irradiation-ray scanner at Aflao Border, Ghana

    International Nuclear Information System (INIS)

    Agbemafo, Edwin Capacity

    2016-07-01

    This study examines the current state of the shielding integrity of the 38.7 TBq Co-60 gamma ray scanner with an average energy of 1.25 MeV operated by NICK TC Scan Limited, which has been in use for destination inspection at Aflao Border of Ghana, for the past six years, (2010-2016). The facility uses a high energy ionizing radiation in its operation; therefore continuous adequacy of the installed biological shielding is critical to the protection and safety of the workers and the general public. The workload of the facility has increased since its commissioning, requiring the review of the status of the installed shielding. Theoretical calculations for dose rates and barrier thicknesses based on tenth – value layer (TVL) concept and NCRP 151, 2005 recommendations, were done around the scanning facility using the current operational data. The results were then compared with the measured dose rates and the shielding thickness constituted during the commissioning stage, and international standards. Calculated dose rate at commissioning state ranges from 0.6μSv/hr to 2.4μSv/hr with an average dose rate of 1.43μSv/hr and that of the current operational state ranges from 1.1μSv/hr to 2.6μSv/hr with an average dose rate of 1.54μSv/hr, indicating an increase of 7.9%. Even though the dose rates were all below the recommended dose limit of 20μSvh"-"1 by NCRP, there has been an increase in dose to the staff and the general public. It has been observed that, the workload has increased three-fold from the commissioning stage to current operational state over the past six years. The assessment done on the installed shielding using the current operational data indicates that the shielding is inadequate in providing protection for the general public and the workers against X-ray radiation source of energy of at least 6MeV, and therefore the facility in its current state cannot be used to house a linear accelerator of energy up to 10MeV. (au)

  9. Effects of gamma and electron beam irradiation on the microbial quality of steamed tofu rolls

    International Nuclear Information System (INIS)

    Jia, Qian; Gao, Meixu; Li, Shurong; Wang, Zhidong

    2013-01-01

    The effectiveness of two kinds of radiation processing, gamma and electron beam (ebeam) irradiation, for the inactivation of Staphylococcus aureus, Salmonella enteritidis and Listeria innocua which were inoculated in pre-sterilised steamed tofu rolls was studied. The corresponding effects of both irradiation types on total bacterial counts (TBCs) in commercial steamed tofu rolls available in the market were also examined. The microbiological results demonstrated that gamma irradiation yielded D 10 values of 0.20, 0.24 and 0.22 kGy for S. aureus, S. enteritidis and L. innocua, respectively. The respective D 10 values for ebeam irradiation were 0.31, 0.35 and 0.27 kGy. Gamma and ebeam irradiation yielded D 10 values of 0.48 and 0.43 kGy for total bacterial counts in commercial steamed tofu rolls, respectively. The results suggest that ebeam irradiation has similar effect on decreasing TBCs in steamed tofu rolls, and gamma irradiation is slightly more effective than ebeam irradiation in reducing the populations of pathogenic bacteria. The observed differences in D 10 -values between them might be due to the significant differences in dose rate applied, and radiation processing of soybean products to improve their microbial quality could be available for other sources of protein. - Highlights: ► Our research material is steamed tofu rolls, a kind of soybean products. ► We compared the effects of gamma ray and electron beam irradiation. ► Total bacterial and three strains of pathogens are studied in our research. ► We reported electron beam has similar decontamination effect as gamma ray. ► Radiation processing of soybean products to improve their microbial quality could be available for other sources of protein.

  10. Advanced carbon-based material C60 modification using partially ionized cluster and energetic beams

    International Nuclear Information System (INIS)

    Du Yuancheng; Ren Zhongmin; Ning Zhifeng; Xu Ning; Li Fuming

    1997-01-01

    Two processes have been undertaken using Partially ionized cluster deposition (PICBD) and energetic ion bombardment beams deposition (IBD) respectively. C 60 films deposited by PICBD at V=0 and 65 V, which result in highly textured close-packed structure in orientation (110) and being more polycrystalline respectively, the resistance of C 60 films to oxygen diffusion contamination will be improved. In the case of PICBD, the ionized C 60 soccer-balls molecules in the evaporation beams will be fragmented in collision with the substrate under the elevated accelerating fields Va. As a new synthetic IBD processing, two low energy (400 and 1000 eV) nitrogen ion beams have been used to bombard C 60 films to synthesize the carbon nitride films

  11. V79 survival following simultaneous or sequential irradiation by 14.8-MeV neutrons and 60Co photons

    International Nuclear Information System (INIS)

    Higgins, P.D.; DeLuca, P.M. Jr.; Pearson, D.W.; Gould, M.N.

    1981-01-01

    A unique tandem source irradiation facility, comprised of an intense d-T neutron source and a 60 Co teletherapy unit, has been used to investigate biological response for different neutron/photon configurations. V79 Chinese hamster cells, attached as monolayers in log phase growth, were irradiated at 37 0 C by either 14.8 MeV neutrons, 60 Co or by a mixture of 40% neutrons - 60% photons in simultaneous or sequential application. Measurements of cell survival indicate an increased effectiveness in cell killing for simultaneously administered neutrons and photons than was measured or predicted for sequentially applied beam modalities. An understanding of the magnitude of these interactive effects is important both for calculating accurate effective doses for neutron radiotherapy of deep-seated tumors, for which the photon component is appreciable and for determination of environmental hazards to people occupationally exposed to low levels of photons and neutrons

  12. Structural and magnetic properties of ion-beam bombarded Co/Pt multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Lin, K.W.; Guo, J.Y.; Lin, S.R.; Ouyang, H. [Department of Materials Science and Engineering, National Chung Hsing University, Taichung 402 (China); Tsai, C.J. [Department of Materials Science and Engineering, National Tsing Hua University, Hsinchu 300 (China); Van Lierop, J. [Department of Physics and Astronomy, University of Manitoba, Winnipeg (Canada); Phuoc, N.N.; Suzuki, T. [Information Storage Materials Laboratory, Toyota Technological Institute, Nagoya 468-8511 (Japan)

    2007-12-15

    A series of [Pt(2 nm)/Co(2 nm)]{sub 10}/Pt(30 nm) multilayers were deposited by using an ion-beam technique. X-ray diffraction and transmission electron microscopy results have shown that as-deposited samples consist of h.c.p. Co and f.c.c. Pt phases. Disordered CoPt{sub 3} phases were developed with increasing End-Hall voltage (V{sub EH}) that induces greater ion-beam bombardment energy during deposition. This indicates that intermixing of Co and Pt increases with ion-beam bombardment. The coercivities (ranging from 100 Oe to 300 Oe) of Co/Pt multilayers decreased with increasing V{sub EH}. After annealing, the formation of CoPt{sub 3} was observed in these ion-beam bombarded samples, resulting in lower coercivities (H{sub c}{proportional_to} 50 Oe). The depressed transition temperature of CoPt{sub 3} for films deposited with the largest V{sub EH} was attributed to distorted CoPt{sub 3} structures that appeared with annealing. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  13. In vitro response of the human breast cancer cell line MDAMB-231 and human peripheral blood mononuclear cells exposed to 60Co at single fraction

    International Nuclear Information System (INIS)

    Andrade, Lidia Maria; Campos, Tarcisio Passos Ribeiro de; Leite, M.F.; Goes, A.M.

    2005-01-01

    Radiotherapy using gamma rays is a common modality of breast cancer treatment. The aim of this research is to investigate the biological response of the human breast cancer cell line MDAMB-231 and human peripheral blood mononuclear cells (PBMC) exposed in vitro to 60 Co irradiation at a single fraction of 10 Gy, 25 Gy and 50 Gy doses at 136,4 cGy.min -1 rate. Cells were irradiated at room temperature by the Theratron 80 radiotherapy system. Biological response was evaluated through cellular viability using MTT assay and nucleus damages visualized by Propidium Iodide assay and electrophoresis agarose gel after gamma irradiation. Nucleus damages induced by 60 Co irradiation were compared to damage caused by cell exposure to 10% methanol. The 50 Gy dose of irradiation did not stimulate nucleus damages at the same level as that affected by 10% methanol induction in the MDAMB-231. Further studies are necessary to understand these mechanisms in the MDAMB-231 human breast carcinoma cell line.(author)

  14. Effects of gamma radiation of Cobalt-60 on different phases of the evolutive cycle of pinworm - Tuta absoluta (Meyrich, 1917) (Lepidoptera,Gelechiidae)

    International Nuclear Information System (INIS)

    Groppo, Gerson Antonio

    1996-10-01

    The effects of different gamma radiation (Cobalt-60) doses on different phases of the evolutive cycle of Tuta absoluta (Meyrich, 1917) (Lepidoptera, Gelechiidae) have been studied under laboratory conditions in the laboratory of Entomology of Center for Nuclear Energy in Agriculture (CENA), University of Sao Paulo, Piracicaba, Sao Paulo State, Brazil. For all the treatments with gamma radiation a Cobalt-60 source type Gamma beam-650 was used. The doses utilized ranged from of 0,0 (Control) to 3250 Gy with a dose rate of 1110 Gy/h. The experiment was conducted under controlled conditions at 25± 2 deg C, 70 ± 5% of relative humidity and photo period of (12:12). It was verified that the lethal doses were: for eggs - 70 Gy; for larvae - 200 Gy e for pupae - 300 Gy. The sterilizing dose for adults from irradiated larvae was 45 Gy. The sterilizing dose for the crossing of irradiated female with normal males (FI X MN) was 100 Gy and for normal female with irradiated male (FN x MI) was 150 Gy, in the both crosses, doses refer to irradiation of pupae. The sterilizing dose for adults, of both sexes, irradiated and crossed with normal adults, (FI x MN) and (FN x MI, were 150 and 200 Gy, respectively. The average longevity of adults, of both sexes, irradiated and crossed with normal adults was 8,3 days. The immediate lethal dose for adults was 3250 Gy. (author)

  15. 60Co-labeling in 59Co(n,γ)60Co reaction and γ-ray irradiation of [Co(dien)2]3+ and [Co(en)3]3+ in crystals and/or in polyvinyl alcohol

    International Nuclear Information System (INIS)

    Sasaki, K.; Iiyoshi, N.; Watanabe, J.; Yamatera, H.

    1982-01-01

    Three isomers (sym-fac, unsym-fac, and mer forms) of [Co(dien) 2 ]Cl 3 were irradiated in a reactor in the form of crystals and in amorphous solids, where the ions were dissolved in polyvinyl alcohol (PVA) or adsorbed on an SP-Sephadex ion exchanger. The distribution of produced 60 Co among the isomers of the Co(III) complex and the Co(II) species was determined. The preferential labeling on the parent isomer was observed in crystals but not in PVA. In the Sephadex, no marked labeling occurred. For comparison with reactor-irradiated samples, mixed solutions of [Co(dien) 2 ]Cl 3 and 60 Co-labeled cobalt (II) chloride dissolved in PVA films ([Co(III)]/[Co(II)] = 2 - 3) were irradiated by γ-rays. Significant labeling was observed after the irradiation. Comparison of the results from the above experiments showed that the labeling was enhanced by radiation chemical reactions, and that the preferential labeling on the parent isomer of crystal samples resulted from the stiffness of the crystal matrix. (orig.)

  16. Prospects for utilization of Electron Beam Accelerators (EBAs) for processing of food products

    International Nuclear Information System (INIS)

    Sarma, K.S.

    2014-01-01

    Radiation processing using gamma radiation and high energy electron beams has been in practice for more than three decades in the industry. Since gamma radiation has the ability of higher penetration in the material, large scale irradiators (mainly based on mega curies of 60 Co radioactive source) are successfully employed for treating bulk products in sterilization and food preservation applications. Electron beam, due to its low penetration, has been exploited exclusively for applications involving polymer modifications to irradiate thin finished end products like electrical cable insulations, heat shrinkable sheets, tubes, automobile tyres etc using high power EBAs (energies 0.5 MeV-4 MeV and powers around ∼100 kW). Out of around 2500 industrial EB units currently employed worldwide (with total installed power above 150 MWL 90% are in the low to medium energy range (0.5 MeV to 4 MeV) being used for polymer modifications. However, recent technological advances in the manufacturing sector of industrial high energy EBAs and product handling systems resulted in widening utilization of EB technology for applications involving bulk product irradiation

  17. Concentration of 60Co by marine organisms through sediments

    International Nuclear Information System (INIS)

    Nakahara, Motokazu; Koyanagi, Taku; Saiki, Masamichi

    1976-01-01

    Uptake of 60 Co absorbed on sea sands by benthic marine organisms was observed in laboratory experiments, since the radioactive cobalt released from nuclear power plants or other establishments into coastal seawater trends to be absorbed on sea sediments and also various kinds of marine organisms live in bottom sediments. Few kinds of flatfishes (Limanda spp.) and shrimp (Trachypenaeus curvirostris) were reared in aquariums contained seawater and sea sands which were highly contaminated with 60 Co previously, and whole body retention and distribution of radioactivity were measured on the organisms taken up from the aquariums occasionally by a scintillation counter. Uptake of 60 Co from ingested sea sands was also observed on the flatfishes administrating the contaminated sands orally. Concentration of 60 Co by the flatfishes reared in the sands was not significant while the shrimp showed high retention of the radioactivity. The food habit of shrimp which usually feeds on organic detritus with other small benthic organisms is different from that of flatfishes, one of the carnivorous, and considered to bring the difference on the pathway of radionuclides concentration. Assimilation of 60 Co via the digestive tract of flatfishes through the sands was estimated as about 10 per cent of the administrated radioactivity. (auth.)

  18. Decommissioning of a 60Co unit and estimation of personal doses

    International Nuclear Information System (INIS)

    Lin, H.; Lin, P.; Liu, T.; Chu, C.

    2003-01-01

    Chang-hua Christian hospital needs to uninstall the 60 Co unit. The mode of this 60 Co teletherapy unit is SHIMADZU RTGS-10. The original lead head was taken as the source container of this 60 Co unit. The source head was dismantled and put into the prepared wooden box, after the source was sealed. This study describes the planning and dismantling of the retirement and transport of the 60 Co unit, and personal doses measured during the procedure. This work estimates the doses of radiation received by exposed workers during the dismantling of the machine. The workers received doses of approximately 53 μSv. This study shows that the original lead head can be used as the source container of this 60 Co unit. The 60 Co machine was smoothly dismantled and transported by conscientious and careful workers, using planned and controlled radiation protection, following the ALARA (as low as reasonably achievable) rule. (author)

  19. C-188 Co-60 sources installation and source rack loading optimization processes in a gamma irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Paulo de S.; Vasquez, Pablo A.S., E-mail: psantos@ipen.br, E-mail: pavsalva@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Since 2004, the Multipurpose Gamma Facility at the Nuclear and Energy Research Institute has been providing services on radiation processing for disinfection and sterilization of health care and disposable medical products as well to support research studies on modification of physical, chemical and biological properties of several materials. Recently, there was an increment in irradiation of the Cultural Heritages. This facility uses C-188 double-encapsulated radioactive Cobalt-60 sources known as pencils from manufactures outside of country. The activity of the cobalt sources decays into a stable nickel isotope with a half-life around 5.27 years, which means a loss of 12.3% annually. Then, additional pencils of Cobalt-60 are added periodically to the source rack to maintain the required capacity or installed activity of the facility. The manufacturer makes shipping of the radioactive sources inside a high density container type B(U) , by sea. This one involves many administrative, transport and radiation safety procedures. Once in the facility, the container is opened inside a deep pool water to remove the pencils. The required source geometry of the facility is obtained by loading these source pencils into predetermined diagram or positions in source modules and distributing these modules over the source rack of the facility. The dose variation can be reduced placing the higher activity source pencils near the periphery of the source rack. In this work are presented the procedures for perform the boiling leaching tests applied to the container, the Cobalt-60 sources installation, the loading processes and the source rack loading optimization. (author)

  20. Effects of gamma Co-60 radiation on the growth and development of peppermint (Mentha arvensis L.)

    International Nuclear Information System (INIS)

    Tran Thi Le Minh; Nguyen Truong Giang; Bui Thi Hong Gam; Le Quang Luan

    2015-01-01

    In this study, mints were regenerated from calluses irradiated by γ-rays (Co-60) at doses from 0 to 70 Gy. After 4 times of propagation, the M_1V_4 mints were transferred in a greenhouse for assessments of growth, development and essential oil content. Mint regenerated from calluses irradiated at low doses (0, 3, 4, 6, 8 and 10 Gy) showed no morphological difference compared to the control plants. However, low-dose irradiated mints showed better effect on growth and development, and mints regenerated from 6 Gy-irradiated sample had essential oil content with 1.3 times higher than that of control group. In case of plants irradiated at higher dose (30, 40, 50, 60 and 70 Gy), there were morphological variations such as stem become bigger and color of stem become purple. Especially, samples irradiated at 60 Gy showed better in growth, development and essential oil content (1.34 times higher than the control plants) and these characters were stable in M_1V_4. Among the irradiated mints, purple stem variations had the highest essential oil yield with 1.7 times higher than that of the original plants. (author)

  1. Study on the possibility of using a 60 Co therapeutical unity in Intensity Modulated Radiotherapy (IMRT)

    International Nuclear Information System (INIS)

    Dantas, Samuel Cesar

    2009-06-01

    With the increasing advances in complex treatment techniques, there is a tendency to obtain more sophisticated equipment to deliver the dose. The use of 3D conformal radiotherapy is now routine in many radiotherapy facilities as well as the utilization of intensity modulated radiotherapy (IMRT). Both are usually implemented using linear accelerators equipped with multi leaves collimators, which create the conformity and the fluence distributions required. However, the complexity of increasingly sophisticated equipment, such as linear accelerators, requires a frequent quality control of their operation, as well as a detailed and constant maintenance. Even carrying out these procedures, the accelerators may present technical problems interrupting for a long time a treatment using the IMRT technique. Despite the clear practical and technological advantages that linear accelerators have on 60 Co irradiators, these devices occupy an important place in radiotherapy, mainly due to the low cost of equipment installation and maintenance when compared to those required by accelerators. Many radiotherapy facilities that work with IMRT have tele therapeutic isocentric 60 Co units. In principle, such equipment would be able to be used for treatment with IMRT using compensating blocks to modulate the beam. This study investigates this possibility and shows that it is feasible. The comparison of treatment plans of a head-and-neck cancer and other of a cancer of the central nervous system, based on a 60 Co irradiator and a Linac 2300 C/D, presented advantages for the 60 Co irradiator. Furthermore; the delivery of dose obtained with the two systems showed themselves equivalent when compared to their respective plans. (author)

  2. Effects of 2.0 Gy of 60Co gamma rays irradiation on rat embryos

    International Nuclear Information System (INIS)

    Lee, Juing-Yi; Satow, Yukio

    1987-01-01

    Pregnant rats of Donryu strain were exposed to a whole-body 60 Co γ ray irradiation of a single dose of 2.0 Gy (Dose rate: 0.5 Gy/min) on day 7, 8, 9, 10 or 11 of gestation (sperm day = day 0). The rats were sacrificed on day 18 and the offspring were examined for external and visceral malformations. Malformed embryos occurred between days 7 and 11 with the highest incidence occurring on day 9. Dose with 2.0 Gy increased the rate of resorption or death (52.1 %), in the survivors, caused congenital malformation in a majority of embryos (86.5 %) on day 8 of gestation. There is an increase in malformation (93.3 %) and growth retardation, but no increase in mortality (42.9 %) on day 9 of gestation. Relatively few anomalies resulted from irradiation on day 7 of gestation. The peak day for cardiovascular anomalies occurred on day 9 (88.3 % of all survival embryos) with high levels also occurring on day 8 (86.5 %). Cardiovascular anomalies consisted of VSD, hypoplasia of the pulmonary trunk, coarctation of the aorta, double aortic arch, right aortic arch, riding aorta, complete transposition of the aorta, persistent atrioventricular canal, vascular ring, aberrant right subclavian artery and others. Similar anomalies, but at a lower incidence, were produced by 60 Co γ ray at dose levels of 2.0 Gy on day 10 or 11 of gestation. Cases of cleft lip and cleft palate or facial cleft were observed seventeen fetuses on day 9 of gestation (31 %). Exencephaly occurred in nine embryos treated on day 9 (16.1 %) and in one embryos treated on day 10. Tail defects appeared with treatment on day 9 with the latter predominating on day 11. The present study show that maximum resorption (52.1 %) was seen with treatment on day 8 whereas the highest rate of malformation (93.3 %) was observed with treatment on day 9. (J.P.N.)

  3. Determination of the Kwall correction factor for a cylindrical ionization chamber to measure air-kerma in 60Co gamma beams

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.; Pimpinella, M.; Bovi, M.

    2002-01-01

    The factor K wall to correct for photon attenuation and scatter in the wall of ionization chambers for 60 Co air-kerma measurement has been traditionally determined by a procedure based on a linear extrapolation of the chamber current to zero wall thickness. Monte Carlo calculations by Rogers and Bielajew (1990 Phys. Med. Biol. 35 1065-78) provided evidence, mostly for chambers of cylindrical and spherical geometry, of appreciable deviations between the calculated values of K wall and those obtained by the traditional extrapolation procedure. In the present work an experimental method other than the traditional extrapolation procedure was used to determine the K wall factor. In this method the dependence of the ionization current in a cylindrical chamber was analysed as a function of an effective wall thickness in place of the physical (radial) wall thickness traditionally considered in this type of measurement. To this end the chamber wall was ideally divided into distinct regions and for each region an effective thickness to which the chamber current correlates was determined. A Monte Carlo calculation of attenuation and scatter effects in the different regions of the chamber wall was also made to compare calculation to measurement results. The K wall values experimentally determined in this work agree within 0.2% with the Monte Carlo calculation. The agreement between these independent methods and the appreciable deviation (up to about 1%) between the results of both these methods and those obtained by the traditional extrapolation procedure support the conclusion that the two independent methods providing comparable results are correct and the traditional extrapolation procedure is likely to be wrong. The numerical results of the present study refer to a cylindrical cavity chamber like that adopted as the Italian national air-kerma standard at INMRI-ENEA (Italy). The method used in this study applies, however, to any other chamber of the same type. (author)

  4. C60 as an Atom Trap to Capture Co Adatoms

    DEFF Research Database (Denmark)

    Yang, Peng; Li, Dongzhe; Repain, Vincent

    2015-01-01

    C60 molecules were used to trap Co adatoms and clusters on a Au(111) surface using atomic/molecular manipulation with a scanning tunneling microscope. Two manipulation pathways (successive integration of single Co atoms in one molecule or direct integration of a Co cluster) were found...... to efficiently allow the formation of complexes mixing a C60 molecule with Co atoms. Scanning tunneling spectroscopy reveals the robustness of the pi states of C60 that are preserved after Co trapping. Scanning tunneling microscopy images and density functional theory calculations reveal that dissociated Co...... clusters of up to nine atoms can be formed at the molecule-substrate interface. These results open new perspectives in the interactions between metal adatoms and molecules, for applications in metal-organic devices...

  5. Effects of gamma ray and electron-beam irradiations on survival of anaerobic and facultatively anaerobic bacteria

    International Nuclear Information System (INIS)

    Miyahara, Michiko; Miyahara, Makoto

    2002-01-01

    An extension of the approval for food irradiation is desired due to the increase in the incidence of food poisoning in the world. One anaerobic (Clostridium perfringens) and four facultatively anaerobic (Bacillus cereus, Escherichia coli O157:H7, Listeria monocytogenes, and Salmonella Enteritidis) bacteria irradiated with gamma ray or electron beam (E-beam) were tested in terms of survival on agar under packaging atmosphere. Using pouch pack, effects of two irradiations on survival of anaerobic and facultatively anaerobic bacteria were evaluated comparatively. E-beam irradiation was more effective than gamma ray irradiation in decreasing the lethal dose 10% (D 10 ) value of B. cereus at 4 deg C, slightly more effective in that of E. coli O157, and similarly effective in that of the other three bacteria at 4 deg C. The gamma irradiation of the bacteria without incubation at 4 deg C before irradiation was more effective than that of the bacteria with incubation overnight at 4 deg C before irradiation in decreasing the D10 values of these bacteria (B. cereus, E. coli O157, and L. monocytogenes). Furthermore, ground beef patties inoculated with bacteria were irradiated with 1 kGy by E-beam (5 MeV) at 4 deg C. The inoculated bacteria in the 1-9 mm beef patties were killed by 1 kGy E-beam irradiation and some bacteria in more than 9 mm beef patties were not killed by the irradiation. (author)

  6. Self-powered detector probes for electron and gamma-ray beam monitoring in high-power industrial accelerators

    International Nuclear Information System (INIS)

    Lone, M.A.

    1992-08-01

    A self-powered detector (SPD) is a simple passive device that consists of a coaxial probe with a metallic outer sleeve, a mineral oxide insulating layer, and a metallic inner core. SPDs are used in nuclear reactors for monitoring neutron and gamma ray fields. Responses of various SPDs to electron and gamma ray beams from industrial accelerators were investigated with Monte Carlo simulations. By judicious choice of transmission filters, threshold SPD probes were investigated for on-line monitoring of the beam energy spectrum of the high-power IMPELA industrial electron accelerator. (Author) (14 figs, 16 refs.)

  7. Disinfestation of export oranges and tangerines (Citrus spp) against medfly Ceratitis capitata (Wied., 1824) (Diptera; Tephritidae) by gamma irradiation (Co-60)

    International Nuclear Information System (INIS)

    Costa, N.

    1990-01-01

    A gamma bean 650 cobalt-60 source was utilized for irradiation (0; 10; 50; 100; 200; 300; 400; 500; 750 and 1000 Gy) of fresh ripe fruits artificially interested by immature stages of Ceratitis capitata to determine the sterilizing and lethal doses. The sensorial and chemical analyses did not show any significant differences between the control and irradiated samples. Differences on loss of weight of oranges show that 500 and 1000 Gy doses were responsible for increasing the loss of water content. (author)

  8. Seeds of Camargue rice (Oryza Sativa L. Var Cigalon) and their responses to exposure to 60-Co gamma radiations. Study of the natural phenomenon of radiation protection

    International Nuclear Information System (INIS)

    Bayonove-Barthelemy, Jacqueline

    1978-01-01

    Within the frame of a project aiming at improving a technique of experimental mutagenesis (seed processing by cobalt-60 gamma rays), this research thesis reports the radiobiological characterization of Cigalon rice seeds, the adjustment of techniques of radiation protection, and the definition of processing and irradiation conditions which could reduce the undesirable physiological effects of cobalt-60 gamma radiation on rice seeds. The author reports the study of variations of physiological radio-sensitivity. Damages are assessed by comparing the growth of irradiated seeds with that of non-irradiated seeds. The mechanism of radiation natural protection is studied by comparing an inhibition in distilled water at two temperatures (5 and 24 C) with that obtained with cysteamine (an efficient radiation protection compound)

  9. Dose response curve for prematurely condensed chromosome fragments of human lymphocytes after 60Co-γ ray exposure

    International Nuclear Information System (INIS)

    Gao Jinsheng; Zheng Siying; Bao Hong

    1992-06-01

    The dose-effect relationship of premature condensed chromosome fragments in human lymphocytes irradiated by 60 Co gamma ray was studied by PCC method (premature condensed chromosomes). In addition, The conventional cellular genetics method was also used in the study. The response curve of both methods can represented by two linear equations. The ratio of two slopes, K PCC /K M1 , is about 28. Comparing with conventional method, the PCC method has many advantages such as faster, simpler, more sensitive and accurate. The PCC method used in the studying of radiation damage is also discussed

  10. Comparative study on disinfection potency of spore forming bacteria by electron-beam irradiation and gamma-ray irradiation

    International Nuclear Information System (INIS)

    Takizawa, Hironobu; Suzuki, Satoru; Suzuki, Tetsuya; Takama, Kozo; Hayashi, Toru; Yasumoto, Kyoden.

    1990-01-01

    Along with gamma-ray irradiation, electron-beam irradiation (EB) is a method to disinfect microorganisms which cause food decomposition and food-poisoning. The present study was undertaken to compare sterilization efficacy of EB and gamma-ray irradiation on bacterial spores and vegetative cells under various conditions. Spores of Bacillus pumilus, a marker strain for irradiation study, and Bacillus stearothermophilus known as a thermophilic bacteria were irradiated by electron-beam and gamma-ray separately at irradiation dose of 0 to 10 kGy on combination of wet/dry and aerobic/anaerobic conditions. Sterilization effect of irradiation on spores was evaluated by colony counting on agar plates. Results showed that both EB and gamma-ray irradiation gave sufficient sterilization effect on spores, and the sterilization effect increased exponentially with irradiation dose. The sterilization effect of gamma-ray irradiation was higher than that of EB in all cases. Higher disinfection effect was observed under aerobic condition. The present study suggests that oxygen supply in EB is more important than gamma-ray irradiation. No results suggesting that chlorine ion at 0.1 ppm (as available chlorine concentration) enhanced the sterilization efficacy of either EB or gamma-ray irradiation was obtained under any conditions examined. (author)

  11. Comparative study on disinfection potency of spore forming bacteria by electron-beam irradiation and gamma-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Takizawa, Hironobu; Suzuki, Satoru; Suzuki, Tetsuya; Takama, Kozo [Hokkaido Univ., Hakodate (Japan). Faculty of Fisheries; Hayashi, Toru; Yasumoto, Kyoden

    1990-10-01

    Along with gamma-ray irradiation, electron-beam irradiation (EB) is a method to disinfect microorganisms which cause food decomposition and food-poisoning. The present study was undertaken to compare sterilization efficacy of EB and gamma-ray irradiation on bacterial spores and vegetative cells under various conditions. Spores of Bacillus pumilus, a marker strain for irradiation study, and Bacillus stearothermophilus known as a thermophilic bacteria were irradiated by electron-beam and gamma-ray separately at irradiation dose of 0 to 10 kGy on combination of wet/dry and aerobic/anaerobic conditions. Sterilization effect of irradiation on spores was evaluated by colony counting on agar plates. Results showed that both EB and gamma-ray irradiation gave sufficient sterilization effect on spores, and the sterilization effect increased exponentially with irradiation dose. The sterilization effect of gamma-ray irradiation was higher than that of EB in all cases. Higher disinfection effect was observed under aerobic condition. The present study suggests that oxygen supply in EB is more important than gamma-ray irradiation. No results suggesting that chlorine ion at 0.1 ppm (as available chlorine concentration) enhanced the sterilization efficacy of either EB or gamma-ray irradiation was obtained under any conditions examined. (author).

  12. Computer generation of cobalt-60 single beam dose distribution using an analytical beam model

    International Nuclear Information System (INIS)

    Jayaraman, S.

    1981-01-01

    A beam dose calculation model based on evaluation of tissue air ratios (TAR) and scatter air ratios (SAR) for cobalt-60 beams of rectangular cross section has been developed. Off-central axis fall-off of primary radiation intensity is derived by an empirical formulation involving an arctangent function with the slope of the geometrical penumbra acting as an essential constant. Central axis TAR and SAR values are assessed by semi-empirical polynomial expressions employing the two sides of the rectangular field as the bariables. The model utilises a minimum number of parametric constants and is useful for computer generation of isodose curves. The model is capable of accounting for situations where wedge filters or split field shielding blocks, are encountered. Further it could be widely applied with minor modifications to several makes of the currently available cobalt-60 units. The paper explains the model and shows examples of the results obtained in comparison with the corresponding experimentally determined dose distributions. (orig.) [de

  13. Modematic: a fast laser beam analyzing system for high power CO2-laser beams

    Science.gov (United States)

    Olsen, Flemming O.; Ulrich, Dan

    2003-03-01

    The performance of an industrial laser is very much depending upon the characteristics of the laser beam. The ISO standards 11146 and 11154 describing test methods for laser beam parameters have been approved. To implement these methods in industry is difficult and especially for the infrared laser sources, such as the CO2-laser, the availabl analyzing systems are slow, difficult to apply and having limited reliability due to the nature of the detection methods. In an EUREKA-project the goal was defined to develop a laser beam analyzing system dedicated to high power CO2-lasers, which could fulfill the demands for an entire analyzing system, automating the time consuming pre-alignment and beam conditioning work required before a beam mode analyses, automating the analyzing sequences and data analysis required to determine the laser beam caustics and last but not least to deliver reliable close to real time data to the operator. The results of this project work will be described in this paper. The research project has led to the development of the Modematic laser beam analyzer, which is ready for the market.

  14. Development of prompt gamma measurement system for in vivo proton beam range verification

    International Nuclear Information System (INIS)

    Min, Chul Hee

    2011-02-01

    In radiation therapy, most research has focused on reducing unnecessary radiation dose to normal tissues and critical organs around the target tumor volume. Proton therapy is considered to be one of the most promising radiation therapy methods with its physical characteristics in the dose distribution, delivering most of the dose just before protons come to rest at the so-named Bragg peak; that is, proton therapy allows for a very high radiation dose to the tumor volume, effectively sparing adjacent critical organs. However, the uncertainty in the location of the Bragg peak, coming from not only the uncertainty in the beam delivery system and the treatment planning method but also anatomical changes and organ motions of a patient, could be a critical problem in proton therapy. In spite of the importance of the in vivo dose verification to prevent the misapplication of the Bragg peak and to guarantee both successful treatment and patient safety, there is no practical methodology to monitor the in vivo dose distribution, only a few attempts have been made so far. The present dissertation suggests the prompt gamma measurement method for monitoring of the in vivo proton dose distribution during treatment. As a key part of the process of establishing the utility of this method, the verification of the clear relationship between the prompt gamma distribution and the proton dose distribution was accomplished by means of Monte Carlo simulations and experimental measurements. First, the physical properties of prompt gammas were investigated on the basis of cross-section data and Monte Carlo simulations. Prompt gammas are generated mainly from proton-induced nuclear interactions, and then emitted isotropically in less than 10 -9 sec at energies up to 10 MeV. Simulation results for the prompt gamma yield of the major elements of a human body show that within the optimal energy range of 4-10 MeV the highest number of prompt gammas is generated from oxygen, whereas over the

  15. Gamma irradiation treatment of secondary sewage effluent

    International Nuclear Information System (INIS)

    Vajdic, A.H.

    The operation and monitoring of a pilot scale Co-60 gamma irradiation unit treating secondary sewage effluent is described. The disinfecting efficiency of the unit is compared to that of an experimental 'ideal' chlorination unit and to the plant chlorination process. A cost estimate for disinfection by gamma irradiation on a full plant scale is included. (author)

  16. Calibration of a radiation survey meter using Cs-137 gamma source

    International Nuclear Information System (INIS)

    Khalid, R. O.

    2005-07-01

    The survey instrument smartIon was calibrated at the Secondary Standard Dosimetry Laboratory, Sudan Atomic Energy Commission, in terms of kerma, free in air using Cs-137 gamma radiation. All the calibrations were performed using the reference instrument spherical ionization chamber LS-01. This reference instrument has been calibrated at the International Atomic Energy Agency, Vienna for x-rays, 137 Cs and 60 Co gamma radiation. The air kerma calibration factors for the instrument were determined as the ratio of the dose rates obtained with the reference standard chamber LS-01 and the dose rates of the instrument under calibration. The uncertainties for the survey meter smartIon and another survey meter RADOS were obtained and the results compared with the uncertainty for the reference standard chamber. Also, the values of dose rates were obtained for various angles of the incident beam, by changing the angle by which the radiation was incident on the sensitive point of the instrument.(Author)

  17. Sensitivity of P-Channel MOSFET to X- and Gamma-Ray Irradiation

    Directory of Open Access Journals (Sweden)

    Milić Pejović

    2013-01-01

    Full Text Available Investigation of Al-gate p-channel MOSFETs sensitivity following irradiation using 200 and 280 kV X-ray beams as well as gamma-ray irradiation of 60Co in the dose range from 1 to 5 Gy was performed in this paper. The response followed on the basis of threshold voltage shift and was studied as a function of absorbed dose. It was shown that the most significant change in threshold voltage was in the case of MOSFET irradiation in X-ray fields of 200 kV and when the gate voltage was +5 V. For practical applications in dosimetry, the sensitivity of the investigated MOSFETs was also satisfactory for X-ray tube voltage of 280 kV and for gamma rays. Possible processes in gate oxide caused by radiation and its impact on the response of MOSFETs were also analyzed in this paper.

  18. Research on degradation of vacuum O-rings under gamma radiation

    CERN Document Server

    Ino, H; Saitô, Y; Kubo, T; Kinsho, M

    2003-01-01

    The high-intensity proton accelerator being constructed by JAERI and KEK will generates greater beam power than conventional accelerators. The radiation emission due to beam losses will therefore increase. Since vacuum O-rings installed in the accelerator will be degraded badly by the radiation, there is need to find an O-ring that has more resistant to radiation. To find an O-ring that has better radiation resistant than that of the fluororubber used for conventional accelerators in general, some O-rings which are expected to have enough resistant to the radiation were irradiated, and estimated a degradation by measurement of outgassing rate, hardness, permeation time of helium gas, and an outward observation. Most of the O-rings were irradiated in an oxygen free atmosphere and in the air. The irradiations were carried out at room temperature in Co-60 gamma irradiation facility until a dose of 1 MGy was reached. The radiation resistance of PURE-RUBBER O-ring showed somewhat better than that of the fluororubb...

  19. Biochemical and hematological study of goats envenomed with natural and 60Co-irradiated bothropic venom

    International Nuclear Information System (INIS)

    Lucas de Oliveira, P.C.; Madruga, R.A.; Barbosa, N.P.U.; Sakate, M.

    2007-01-01

    Venoms from snakes of the Bothrops genus are proteolytic, coagulant, hemorrhagic and nephrotoxic, causing edema, necrosis, hemorrhage and intense pain at the bite site, besides systemic alterations. Many adjuvants have been added to the venom used in the sensitization of antiserum-producer animals to increase antigenic induction and reduce the envenomation pathological effects. Gamma radiation from 60 Co has been used as an attenuating agent of the venoms toxic properties. The main objective was to study, comparatively, clinical and laboratory aspects of goats inoculated with bothropic (Bothrops jararaca) venom, natural and irradiated from a 60 Co source. Twelve goats were divided into two groups of six animals: GINV, inoculated with 0.5 mg/kg of natural venom; and GIIV, inoculated with 0.5 mg/kg of irradiated venom. Blood samples were collected immediately before and one, two, seven, and thirty days after venom injection. Local lesions were daily evaluated. The following exams were carried out: blood tests; biochemical tests of urea, creatinine, creatine kinase, aspartate amino-transferase and alanine amino-transferase; clotting time; platelets count; and total serum immunoglobulin measurement. In the conditions of the present experiment, irradiated venom was less aggressive and more immunogenic than natural venom. (author)

  20. Monte Carlo simulation of the Leksell Gamma Knife: I. Source modelling and calculations in homogeneous media

    Energy Technology Data Exchange (ETDEWEB)

    Moskvin, Vadim [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN (United States)]. E-mail: vmoskvin@iupui.edu; DesRosiers, Colleen; Papiez, Lech; Timmerman, Robert; Randall, Marcus; DesRosiers, Paul [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN (United States)

    2002-06-21

    The Monte Carlo code PENELOPE has been used to simulate photon flux from the Leksell Gamma Knife, a precision method for treating intracranial lesions. Radiation from a single {sup 60}Co assembly traversing the collimator system was simulated, and phase space distributions at the output surface of the helmet for photons and electrons were calculated. The characteristics describing the emitted final beam were used to build a two-stage Monte Carlo simulation of irradiation of a target. A dose field inside a standard spherical polystyrene phantom, usually used for Gamma Knife dosimetry, has been computed and compared with experimental results, with calculations performed by other authors with the use of the EGS4 Monte Carlo code, and data provided by the treatment planning system Gamma Plan. Good agreement was found between these data and results of simulations in homogeneous media. Owing to this established accuracy, PENELOPE is suitable for simulating problems relevant to stereotactic radiosurgery. (author)

  1. Development of a high current 60 keV neutral lithium beam injector for beam emission spectroscopy measurements on fusion experiments

    Science.gov (United States)

    Anda, G.; Dunai, D.; Lampert, M.; Krizsanóczi, T.; Németh, J.; Bató, S.; Nam, Y. U.; Hu, G. H.; Zoletnik, S.

    2018-01-01

    A 60 keV neutral lithium beam system was designed and built up for beam emission spectroscopy measurement of edge plasma on the KSTAR and EAST tokamaks. The electron density profile and its fluctuation can be measured using the accelerated lithium beam-based emission spectroscopy system. A thermionic ion source was developed with a SiC heater to emit around 4-5 mA ion current from a 14 mm diameter surface. The ion optic is following the 2 step design used on other devices with small modifications to reach about 2-3 cm beam diameter in the plasma at about 4 m from the ion source. A newly developed recirculating sodium vapour neutralizer neutralizes the accelerated ion beam at around 260-280 °C even during long (manipulation techniques are applied to allow optimization, aiming, cleaning, and beam modulation. The maximum 60 keV beam energy with 4 mA ion current was successfully reached at KSTAR and at EAST. Combined with an efficient observation system, the Li-beam diagnostic enables the measurement of the density profile and fluctuations on the plasma turbulence time scale.

  2. The high intensity {gamma}-ray source (HI{gamma}S) and recent results

    Energy Technology Data Exchange (ETDEWEB)

    Tonchev, A.P. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States)]. E-mail: tonchev@tunl.duke.edu; Boswell, M. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Howell, C.R. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Karwowski, H.J. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Kelley, J.H. [North Carolina State University and TUNL, Raleigh, NC 27695 (United States); Tornow, W. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Wu, Y.K. [Duke University and Duke Free Electron Laser Laboratory, Durham, NC 27708-0319 (United States)

    2005-12-15

    The high intensity {gamma}-ray source (HI{gamma}S) utilizes intra-cavity backscattering of free electron laser photons from the Duke electron storage ring to produce a unique monoenergetic beam of high-flux {gamma}-rays with high polarization and selectable energy resolution. At present, {gamma}-ray beams with energies from 2 to 58 MeV are available with intensities as high as 10{sup 5}-5 x 10{sup 6} {gamma}/s, energy spreads of 3% or better, and nearly 100% linear polarization. The quality and intensity of the {gamma}-ray beams at HI{gamma}S are responsible for the unprecedented performance of this facility in a broad range of research programs in nuclear structure, nuclear astrophysics and nuclear applications. Recent results from excitation of isomeric states in ({gamma}, n) reactions and parity assignments of dipole states determined via the ({gamma}, {gamma}') reaction are presented.

  3. Sensory evaluation of black beans submitted to gamma radiation from Cobalt-60; Avaliacao sensorial de feijao preto submetido a radiacao de Cobalto-60

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Neila Camargo de; Canniatti-Brazaca, Solange Guidolin; Spoto, Marta Helena Fillet, E-mail: sgcbraza@esalq.usp.b [Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), Piracicaba, SP (Brazil). Dept. de Agroindustria, Alimentos e Nutricao; Arthur, Valter [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil). Secao de Entomologia e Irradiacao de Alimentos

    2005-04-15

    The objective of this research was to evaluate the sensory aspects of black beans submitted to gamma radiation from {sup 60}Co. The study involved eight panelists, between 17 to 23 years old, who were selected and trained for the descriptive analysis of appearance, aroma, flavor and texture. The panelists analyzed alterations of appearance, aroma, flavor and texture of non-irradiated and irradiated black beans with doses 2, 4, 6, 8 and 10kGy. The results were analyzed by test F, ANOVA and the Tukey test (5%), with the use of computers and the sensory analysis software Compusense Five and SAS. The results showed that irradiated samples decreased the bitter flavor, accentuated color and brightness and samples non-irradiated dry texture. The radiation treatment is a good method for conservation of black beans in doses evaluated in this study.(author)

  4. A simulation study on the dose distribution for a single beam of the gamma knife

    International Nuclear Information System (INIS)

    Chen, Chin-cheng; Jiang, Shiang-Huei; Lee, Chung-chi; Shiau, Cheng-Ying

    2000-01-01

    The purpose of this study is to evaluate the impact of the tissue heterogeneity on the dose distribution for a single beam of the gamma knife. The EGS4 Monte Carlo code was used to simulate both depth and radial profiles of the radiation dose in homogeneous and heterogeneous phantoms, respectively. The results are compared with the dose distribution calculated using the mathematical model of Gamma Plan, the treatment planning system of the gamma knife. The skull and sinus heterogeneity were simulated by a Teflon shell and an air shell, respectively. It was found that the tissue heterogeneity caused significant perturbation on the absolute depth dose at the focus as well as on the depth-dose distribution near the phantom surface and/or at the interface but little effect on the radial dose distribution. The effect of the beam aperture on the depth-dose distribution was also investigated in this study. (author)

  5. Multistep carcinogenesis of normal human fibroblasts. Human fibroblasts immortalized by repeated treatment with Co-60 gamma rays were transformed into tumorigenic cells with Ha-ras oncogenes.

    Science.gov (United States)

    Namba, M; Nishitani, K; Fukushima, F; Kimoto, T

    1988-01-01

    Two normal mortal human fibroblast cell strains were transformed into immortal cell lines, SUSM-1 and KMST-6, by treatment with 4-nitroquinoline 1-oxide (4NQO) and Co-60 gamma rays, respectively. These immortalized cell lines showed morphological changes of cells and remarkable chromosome aberrations, but neither of them grew in soft agar or formed tumors in nude mice. The immortal cell line, KMST-6, was then converted into neoplastic cells by treatment with Harvey murine sarcoma virus (Ha-MSV) or the c-Ha-ras oncogene derived from a human lung carcinoma. These neoplastically transformed cells acquired anchorage-independent growth potential and developed tumors when transplanted into nude mice. All the tumors grew progressively without regression until the animals died of tumors. In addition, the tumors were transplantable into other nude mice. Normal human fibroblasts, on the other hand, were not transformed into either immortal or tumorigenic cells by treatment with Ha-MSV or c-Ha-ras alone. Our present data indicate that (1) the chemical carcinogen, 4NQO, or gamma rays worked as an initiator of carcinogenesis in normal human cells, giving rise to immortality, and (2) the ras gene played a role in the progression of the immortally transformed cells to more malignant cells showing anchorage-independent growth and tumorigenicity. In other words, the immortalization process of human cells seems to be a pivotal or rate-limiting step in the carcinogenesis of human cells.

  6. Soil properties related to 60Co bioavailability in tropical soils

    International Nuclear Information System (INIS)

    Bartoly, Flavia; Wasserman, Maria Angelica; Rochedo, Elaine Ruas Rodriguez; Viana, Aline Gonzalez; Souza, Rodrigo Camara; Oliveira, Giselle Rodrigues; Reis, Wagner Goncalves Soares; Perez, Daniel Vidal

    2005-01-01

    This work presents the results of field experiments to obtain soil to plants Transfer factor (TF) for 60 Co in reference plants cultivated in Ferralsol, Acrisol and Nitisol. These soils represent the majority of Brazilian agricultural area. Values of TF varied from 0.001 to 0.05 for corn and from 0.001 to 0.81 for cabbage. Results of 60 Co TF were discussed in relation to the physical and chemical properties of the soils and 60 Co geochemical partition. The sequential chemical extraction showed that more than 40% of the 60 Co present in the soils are associated to manganese oxides. These results will provide regional values for parameters used in the environmental radiological modeling aiming to optimize the planning of emergency interventions or the waste management related to tropical soils. (author)

  7. Dosimetric evaluation of Radiotherapy units wit {sup 60}Co; Evaluacion dosimetrica de unidades de radioterapia con {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Leon, B. Salinas de; Tovar M, V.; Becerril V, A. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    The SSDL network of the IAEA performs, every year, quality audit tests for radiotherapy services ({sup 60} Co units and linear accelerators), and for national SSDL as well. Because of the SSDL-Mexico results in these tests and due to our enthusiasm and confidence in our work, a parallel test has been done , which is described in this talk as well as the results. Nowadays, a second parallel test goes up, which could confirm our optimism and open the possibility to our country to start a national dosimetric audit of {sup 60} Co radiotherapy units. (Author)

  8. Calibration curve to establish the exposure dose at Co{sup 60} gamma radiation; Curva de calibracion para establecer dosis de exposicion a radiacion gamma de Co{sup 60}

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C; Brena V, M [Departamento de Biologia, Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, Mexico D.F. (Mexico)

    2000-07-01

    The biological dosimetry is an adequate method for the dose determination in cases of overexposure to ionizing radiation or doubt of the dose obtained by physical methods. It is based in the aberrations analysis produced in the chromosomes. The behavior of leisure in chromosomes is of dose-response type and it has been generated curves in distinct laboratories. Next is presented the curve for gamma radiation produced in the National Institute of Nuclear Research (ININ) laboratory. (Author)

  9. Behavior of the dynamic magnetic susceptibility in ybco bula ceramics irradiated with gamma rays

    International Nuclear Information System (INIS)

    Leyva Fabelo, A.; Bouza Dominguez, J.; Cruz Inclan, Carlos M.

    2001-01-01

    Using measurements of the ac susceptibility, the behavior with the irradiation dose of YBa2Cu3O7- bulk ceramics synthesized by the classic reaction method in solid state, was studied. A Co60 gamma chamber model MPX-G-25M and a Cs137 source were employed as gamma ray sources. The behavior of the beginning temperature of the normal - superconducting state transition with the exposition dose show, independently of the incident gamma energy, a monotonous growth until reaching a threshold dose, after which, observe a fall, more abrupt in the case of the Co60. This behavior can be explained using the model that postulates the ability of the gamma radiation, in certain dose intervals, to stimulate the structural reordering in the oxygen sublattice. When the irradiation process takes place in the Co60 gamma chamber, the behavior of the superconducting volume fraction of the sample characterizes by the initial sharp fall with the dose, followed with an attenuation of the decrement. In the case of Cs137 irradiation, the behavior of the superconducting volume fraction is similar to the behavior of the Ton with the dose

  10. Evaluation and comparison of gamma- and electron beam irradiation effects on total and free gossypol of cottonseed meal

    International Nuclear Information System (INIS)

    Shawrang, P.; Mansouri, M.H.; Sadeghi, A.A.; Ziaie, F.

    2011-01-01

    Impact of gamma- and electron beam irradiation on total and free gossypol content of cottonseed meal was assessed by exposing them to doses of 10, 15, 20, 25 and 30 kGy. Gamma rays and electron beam showed the same effects with significant dose-dependent decrease in total and free gossypol content. Based on these results, ionizing irradiation at doses of 25 kGy and above could completely remove free gossypol and bring down total gossypol content to permissible level in poultry feed.

  11. Bioaccumulation and elimination of 60 Co and 137 Cs by Anomalocardia brasiliana (Gmelin, 1791) (Mollusca bivalvia). Remobilization of 60 Co, retained in marine sediment by microbial activity

    International Nuclear Information System (INIS)

    Mayr, L.M.

    1984-05-01

    It was studied the capacity of a bi valve mollusc Anomalocardia brasiliana, which lives in the local bottom sediment, to remobilize 60 Co previously sorbed in the sediment. Laboratory experiments demonstrated that the transference of 60 Co from the sediment to the animal was insignificant (bioaccumulation factor (BF) of the order of 10 -3 ). At the same time, the capacity of microorganisms, present in the bottom sediment, to remobilize 60 Co was studied. The results showed that this via of transference was important, considering the much greater microorganism biomass in relation to the biomass of bentonic organisms, as a whole. For 137 Cs the determined BF from water to the animal was 2.2. and, as in the case of 60 Co, the soft tissues concentrated more 137 Cs than shell. Remaining viscera showed the highest BFs. In another series of experiments, the loss of 60 Co or 137 Cs, previously accumulated by A. brasiliana, was followed in aquaria with or without sediment and the respective biological half-lives were calculated. Soft tissues retained 60 Co longer (biological half-life = 117 days) than shells, whereas for 137 Cs the opposite was observed and shells showed a biological half life of 38.5 days. The low values of 60 Co and 137 Cs BF S do not allow to classify A. brasiliana as good biological indicator for pollution by there radionuclides. However since A brasiliana is consumed by the local population and is commercialized to other areas, it was recommended that its contamination by 60 Co or 137 Cs should be monitored. (author)

  12. Study on the resistance of haloferax radiotolerans, an extreme Halophilic archaebacterium from Uromia lake against ultraviolet (UV) light and 60Co gamma-rays

    International Nuclear Information System (INIS)

    Asgarni, E.; Shirzad, M.; Soudi, M. R.; Shahmohammadi, H. R.; Falsafi, T.

    2006-01-01

    In this work, the capacity of an extreme halophilic archaebacterium, isolated from Uromia lake, Haloferax radiotolerans to withstand the lethal effects of ultraviolet light (UV),and 60 Co r-rays has been studied. The resistibility of this organism against the DNA-damaging agents was evaluated by calculating of the survival fractions at different dose rates of W and 60 Co r-rays radiations and compared with those of Escherichia coli B/r (a radioresistant strain of E. coli). D 37 values for Haloferax radiotolerans and E. coli B/r were 23 1, and 9 J/m 2 , respectively, by exposure to the UV light. They were 645, and 99 Gy, respectively, by exposure to 60 Co r-rays. Against these agents, Haloferax radiotolerans shows much more resistance compare to that of E. coli B/r. This is categorized as the first report of resistibility in the member of Archaea

  13. Effects of 60Co gamma radiation on defense function of human polymorphonuclear leukocytes

    International Nuclear Information System (INIS)

    Sasagawa, Sumiko; Suzuki, Kazuo; Sakatani, Tatsuichiro; Brooks, G.T.; Fujikura, Toshio.

    1986-06-01

    The effects of radiation on defense function of polymorphonuclear leukocytes (PMN) were studied following irradiation with 60 Co γ radiation (30 - 3,000 rad) using PMN separated from the peripheral blood of healthy volunteers. The migration distances for all three measures of chemotaxis to fMet-Leu-Phe (10 -8 M), chemokinesis induced by fMet-Leu-Phe, and random migration tended to decrease with increasing dose, showing 0.0054 μm/rad (p -5 M) in conjunction with cytochalasin B (CB, 5 μg/ml) there was a significant dose trend, showing the dose effects of decreasing 0.0022 % release/rad for BGL and 0.0030 % release/rad for LYZ with increasing dose. In superoxide anion (O 2 - ) production, a slight and marginally significant linear dose trend was found. These results suggest that the defense function of PMN is not so resistant to radiation as predicted from the fact that PMN in the peripheral blood are differentiated and mature. It is thought that radiation inflicts substantially harmful effects on the defense function of peripheral PMN. (author)

  14. Bioaccumulation of 137Cs and 60Co by Helianthus annuus

    International Nuclear Information System (INIS)

    Hornik, M.; Pipiska, M.; Vrtoch, L.; Augustin, J.; Lesny, J.

    2005-01-01

    The 60 Co and 137 Cs bioaccumulation by Helianthus annuus L. was measured during 9 day cultivation at 20 ± 2 o C in hydroponic Hoagland medium. Previous starvation for K + and for NH 4 + 2.2 and 2.7 times, respectively, enhanced 137 Cs uptake rate. Previous cultivation in surplus of K + ions 50 mmol·l -1 has no effect on 137 Cs bioaccumulation rate. Both 137 Cs and 60 Co bioaccumulation significantly increase with dilution of basic Hoagland medium up to 1:7 for caesium and up to 1:3 for cobalt followed by mild decrease at higher dilutions. Root to shoot specific 137 Cs radioactivity ratio (Bq.g -1 /Bq·g -1 , fresh wt.) increased with dilution from 1.46 to 9.6-9.8. The values root to shoot specific radioactivity ratio for 60 Co were less dependent on the nutrient concentrations and were within the range 5.7 to 8.5. 137 Cs was localized mainly in young leaves (30%) and roots (39%) and 60 Co mainly in roots (67%) and leaves (20%). Obtained data showed less sensitivity of 60 Co uptake by sunflower on nutrient concentration in hydroponic media. (author)

  15. Safety protection and technical improvement of 60Co irradiation facilities

    International Nuclear Information System (INIS)

    Zhou Yongxing; Liang Cannan

    1993-01-01

    To ensure personal safety, some improvements has been made in the design of 60 Co irradiation compartment. The shielding door was interlocked while the 60 Co source to be lifted to the irradiation position or lowered to the shielded position. A universal change-over switch was used to cut the power supply when the source moved beyond the limits. Both γ-ray alarm and a closed-TV system were adopted. The electromagnetic attraction method was employed to shift the 60 Co source from the Pb container to the source pipe

  16. MoonBEAM: A Beyond Earth-Orbit Gamma-Ray Burst Detector for Gravitational-Wave Astronomy

    Science.gov (United States)

    Hui, C. M.; Briggs, M. S.; Goldstein, A. M.; Jenke, P. A.; Kocevski, D.; Wilson-Hodge, C. A.

    2018-01-01

    Moon Burst Energetics All-sky Monitor (MoonBEAM) is a CubeSat concept of deploying gamma-ray detectors in cislunar space to improve localization precision for gamma-ray bursts by utilizing the light travel time difference between different orbits. We present here a gamma-ray SmallSat concept in Earth-Moon L3 halo orbit that is capable of rapid response and provide a timing baseline for localization improvement when partnered with an Earth-orbit instrument. Such an instrument would probe the extreme processes in cosmic collision of compact objects and facilitate multi-messenger time-domain astronomy to explore the end of stellar life cycles and black hole formations.

  17. Low energy gamma induced radiation damage in YBCO: electrical resistivity and the induced metal - insulator transition behaviors

    International Nuclear Information System (INIS)

    Cruz, Carlos M.; Pinnera, Ibrahin; Leyva, Antonio; Abreu, Yamiel; Sirgado, Nicolas

    2015-01-01

    In the present contribution the superconducting YBCO ρ(T) dependence behavior on the irradiation dose and accumulative time are studied for gamma quanta of E γ = 132 keV ( 57 Co) and 1,25 MeV ( 60 Co) at room temperature. In both cases, possible radiation effects on grain boundary and intragrain zones are evaluated by means of different gamma ray microscopic interaction models. It was conclude that 57 Co gamma quanta (E γ = 132 keV) modules YBCO ρ(T) dependence behavior through enhanced oxygen vacancy diffusion motions which collapse the electron percolative conduction paths in the grain boundary zones, effects which are not observed by irradiation with 60 Co gamma quanta (E γ = 1,25 MeV), in which case main irradiation effects on the electrical conduction mechanisms are limited to the intragrain zones. (Author)

  18. Decontamination of fermented chicken feet by 60Co irradiation

    International Nuclear Information System (INIS)

    Gao Peng; Wang Yan; Huang Min; Wu Ling; Du Xiaoying; Lei Qing; Xie Yan

    2010-01-01

    Fermented chicken feet was treated by 60Co irradiation, and the aerobic plate count, enumeration of coliforms, pathogens and TBARS value were measured during storage. The results showed that, aerobic plate count of all irradiated samples was lower than control, and enumeration of coliforms, and pathogens of Staphylococcus aureus, Shigella, Salmonella were not detected. TBARS value of all treatments was stable during 60 d storage. It could be concluded that 60Co irradiation of chicken feet was an effective method to prolong its shelf life. (authors)

  19. Oxygen enhancement ratio (OER) to Neutron and Co-60 γ ray

    International Nuclear Information System (INIS)

    Kim, Mi Sook; Ji, Young Hoon; Lee, Yong Min; Kim Kyeoung Jung

    1997-01-01

    Experiments in vitro, using human cell lines was carried out in order to establish whether or not there was a difference between oxygen enhancement ratio (OER) of neutron and Co-60 γ-ray and to determine OER dependence on radiation dose. MG-63 cell line and H-460 cell line were defined as the most sensitive cell line to neutron among our laboratory holding cell lines through preliminary study. Anoxia as was produced in glove box. The box was flushed for one hour with a mixture of 5 % CO 2 in ultrapure N 2 (total oxygen concentration < 10 ppm) and irradiated with neutron and Co-60 γ-ray. Oxic condition was same as anoxic condition except being irradiated in general air condition. The lower OER was observed in neutron than in Co-60 γ-ray. The dose dependence of OER was observed in neutron and Co-60 γ-ray all. But the dose dependence of the OER is somewhat larger for Co-60 γ-ray than for neutron. In the range of 1 to 8 Gy, the OER for photon and neutron range from 1.54 to 1.94 and 1.23 to 1.26 in MG-63 cell line. In case of H-460 the OER for Co-60 γ-ray and neutron range from 1.24 to 1.60 and 1.06 to 1.07 respectively. (author). 19 refs., 5 tabs., 5 figs

  20. The Effects of Cobalt-60 Gamma Radiation on Vitamin B{sub 6} and Folic Acid; Effets des rayons gamma (cobalt-60) sur la vitamine B{sub 6} et l’acide folique

    Energy Technology Data Exchange (ETDEWEB)

    Galatzeanu, I.; Antoni, F. [International Atomic Energy Agency, Vienna (Austria)

    1967-09-15

    A study has been made of the behaviour of pyridoxine and folic acid, including structural changes, after {sup 60}Co gamma irradiation. The irradiation of pyridoxine (vitamin B{sub 6}) and folic acid in aqueous solutions leads to their partial or total destruction, depending on the dose. The irradiation of pyridoxine and folic acid in the solid state mainly results in the elimination of hydrogen atoms (free radicals). After dissolving the irradiated samples in acid solutions it was observed that the irradiated molecule was renewed through replacement of the eliminated hydrogen atoms, which depend on the pH-value of the solution. This gives the possibility of sterilizing both pyridoxine and folic acid in the solid state by irradiation at 2 Mrad. Most of the radiolysis products of pyridoxine and folic acid irradiated in solution and in the solid state have been separated and identified by means of chromatography (paper and thin layer) and cellulose column electrophoresis. Electron spin resonance was used to determine the concentration and nature of the free radicals after irradiation of pyridoxine and folic acid in the solid state. (author) [French] On a Studie le comportement de la pyridoxine et de l'acide folique apres exposition aux rayons gamma ({sup 60}Co) et les changements dans leurs structures. L'irradiation de la pyridoxine (Vitamine B{sub 6}) et de l'acide folique en solutions aqueuses enttarne leur destruction partielle ou totale selon la dose. L'irradiation de la pyridoxine et de l'acide folique á l'etat solide enttarne principalement l'elimination d'atomes d'hydrogene (radicaux libres). Par dissolution des echanrilions irradies dans des solutions acides, on a observe un renouvellement de la molecule irradiee par remplacement des atomes d'hydrogene elimines qui est fonction du pH de la solution, ce qui permet de radiosteriliser a 2 Mrad á l'etat solide tant la pyridoxine que l'acide folique. On a separe et identifie la majorite des produits de radiolyse