WorldWideScience

Sample records for cms hcal readout

  1. Radiation Damage of the CERN CMS HCAL Scintillator/WLS fiber readout during Run1 and Run2 of the LHC

    CERN Document Server

    de Barbaro, Pawel Jan

    2017-01-01

    We present the results of a study of radiation damage of the CERN CMS HCAL Scintillator/WLS Fiber readout. Data were obtained using the Laser calibration system of the CMS hadron endcap detector during the operation of the LHC in 2010-2017. Scintillators used in the CMS hadron endcap calorimeter (HE) were irradiated at dose rates in the range of 0.1 rad/h to 0.1 krad/h. Results indicate that the radiation damage has a strong dose rate dependence. Using data collected in 2017, we have measured the response loss in a single HE section instrumented with Silicon photomultipliers (SiPMs). The results show a much smaller signal loss for the channels read out by SiPMs compared to signal loss for the channels read out by hybrid photodetectors (HPDs). The results imply that a large fraction of the response loss in the CMS HE detector observed in 2010-2017 comes from deterioration of the HPD photodetectors and not from radiation damage of scintillators.

  2. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Spalding

    2011-01-01

    Throughout the entire proton-proton run of 2011, all HCAL calorimeters operated very efficiently. Over 99% of HCAL readout and trigger channels were alive. However, during the year we did face two hardware problems. One major operation problem was the occasional loss of data from a single RBX caused by single event upsets (SEUs). The rate of RBX data loss was on average one incident per 10 pb–1 of integrated luminosity. This led to approximately 1% of CMS data loss. In order to mitigate this problem, HCAL has introduced an automatic reset of the RBX. With this reset, full operation was restored within about one minute. The final hardware correction of the problem will be possible only during a long shutdown (LS1) in 2013-’14. Another hardware problem that developed in 2011 was the failure of QPLL (quartz phase lock loops) chips. This led to the loss of phase of the readout clock with respect to the LHC clock. As a consequence, in two sections in HCAL (10 degree in φ on HB and 1...

  3. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    During the last 3 months commissioning of HCAL has continued for HO and HE+. We have also started the commissioning of the first wedge of HB+. Progress continues to be made by our Trigger/DAQ, DCS and DPG colleagues. HF will be used to obtain a Luminosity measurement for CMS. A first test of the modifications to the HF electronics was made in the August CMS global run. In addition to installation and commissioning of various parts of HCAL, we also completed a very successful summer Test Beam period which saw measurements of the combined HE/EE/ES calorimeter system in the H2 test beam. Installation and Commissioning a. HB commissioning This week, part of the final water-cooling system for HB was commissioned. Eighteen HB- wedges and two pilot wedges on HB+ have been connected to the water circuit on YB0. On Sept 6, 2007 cabling and commissioning was started for the first HB readout box (RBX) using temporary set of cables. We have connected RBX-17 to the Low Voltage PS and the HCAL Detector Control Sy...

  4. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    P. De Barbaro and J. Mans

    2012-01-01

      During last three months of LHC operation in 2012 (October–December) the HCAL performed well. Out of a total of 6.5 fb–1 recorded by CMS, 170 pb–1 had to be declared ‘bad’ during the certification process due to HCAL-related problems. Monitoring of HCAL readout using LED detected a continuous loss in the gain of photomultipliers in the HF. The gain loss is found to be related to the current drawn by the PMTs. The LED data are used to correct the calibration of the channels and L1 look-up tables are routinely updated when the maximum deviation in any of the channels reaches the level of 2%. Laser data are used to monitor radiation damage in the HF quartz fibers and HE scintillators. The 2012 data (20 fb–1 delivered) showed radiation-related loss of transparency in the quartz fibers, leading to 8% signal loss at high η (η =5) in HF. In the front sampling layers of HE towers, the scintillators also show radiation damage. ...

  5. First two barrel ECAL supermodules inserted in CMS HCAL

    CERN Multimedia

    K.Bell

    2006-01-01

    The first two barrel "supermodules" for the CMS Electromagnetic Calorimeter (ECAL) have been inserted into the barrel hadron calorimeter (HCAL) in the experimental hall (called SX5) in Cessy in preparation for the forthcoming magnet test and cosmic challenge (MTCC). Each of the two supermodules contains 1700 lead tungstate crystals in glass-fibre alveolar support structures, with associated avalanche photodiodes (APDs, for scintillation light detection), electronics and cooling system. The barrel ECAL will consist of 36 supermodules, many of which have already been produced (see CERN Bulletin 17-18, 2006). Team from CMS ECAL, CMS Integration and CEA-DAPNIA were involved in the insertion, with the production/integration of the supermodules themselves involving many technicians, engineers and physicists from many institutes. From left to right: Olivier Teller, Maf Alidra and Lucien Veillet.

  6. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    Since the beginning of 2007, HCAL has made significant progress in the installation and commissioning of both hardware and software. A large fraction of the physical Hadron Calorimeter modules have been installed in UX5. In fact, the only missing pieces are HE- and part of HO. The HB+/- were installed in the cryostat in March. HB scintillator layer-17 was installed above ground before the HB were lowered. The HB- scintillator layer-0 was installed immediately after completion of EB- installation. HF/HCAL Commissioning The commissioning and checkout of the HCAL readout electronics is also proceeding at a rapid pace in Bldg. 904 and USC55. All sixteen crates of HCAL VME readout electronics have been commissioned and certified for service. Fifteen are currently operating in the S2 level of USC55. The last crate is being used for firmware development in the Electronics Integration Facility in 904. All installed crates are interfaced to their VME computers and receive synchronous control from the fully-equipp...

  7. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Mans and P. De Barbaro

    2012-01-01

      During first three months of LHC operation in 2012 (April-June 2012), HCAL performed well.  Out of a total of 6.15 fb–1 recorded by CMS, 230 pb–1 had to be declared as ‘bad’ during certification process due to HCAL-related problems. There were two major sources of ‘bad’ data coming from HCAL. Firstly, RBX data losses resulted in approximately 90 pb–1 declared as ‘bad’. The RBX data loss problems are caused by Single Event Upsets (SEU) in Clock and Control Modules (CCMs). As CCMs are not accessible with the CMS detector closed, this problem can be only fixed during LS1. The second major source of  ‘bad’ data was a failure of TTCrx chip (installed on HF detector), which resulted in a loss of almost 80 pb–1. The intervention required access to the cavern, and so the unit could only be replaced during the inter-fill period. In 2011 and early 2012, we have...

  8. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    HB installation and commissioning has been completed. The commissioning of HO and HF- is in progress. HE-will be lowered in early 2008 and will be comissioned at that time. HCAL DAQ With the completion of HCAL Barrel commissioning, the HCAL Online Software group has deployed a large number of significant updates to the software. These updates bring the HCAL software closer to final operations. At the core level, the HCAL software has been ported to the latest complete XDAQ release (3.11/Release 4). In parallel, significant effort has been made on zero suppression, front-end configuration, online databases, and monitoring. A major effort since the last CMS Week has been made to enable zero-suppression in HCAL - an effort which involves the DPG, the online SW group, and the firmware/ electronics team. The zero-suppression algorithm was specified by the DPG group based on simulation work, implemented and tested by the firmware team, and supported by the software team. Zero-suppression will be deployed for t...

  9. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    Andris Skuja

    HCAL finished commissioning the central and forward detectors during the summer of 2008. HCAL was able to participate in all global runs. In particular, we were anxious to determine the performance of all of the HCAL HPDs at 3.8T. At this point in time this study still has not been completed because of various difficulties CMS has encountered to reach 3.8T. HF Commissioning The HF produces the raw data for the CMS Luminosity determination. It is also an important part of the min-bias trigger and forward jet triggers and physics. In June 2008 the HFs were out of their garages and being worked upon for Castor/Collar platform installation. The HFs were back in the garage position in July and were subject to a series of checks (mainly LED and laser) before starting the CRUZET3 global runs. As part of this sequence, calibration constants were checked via single photo-electrons, the HV choice was finalized and the relative timing was fixed. During CRUZET3 tests of LUMI were performed, and muon signals were measure...

  10. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    D. Green

    The organization of CMS HCAL contains four “geographic” efforts, HB, HO, HE and HF. In addition there are presently five “common” HCAL activities. These ef¬forts are concentrated on electronics, on controls (DCS), on physics objects (JetMet), on Installation and Commissioning (I&C), and on Test Beam (TB) and Cosmic Challenge (MTCC) data taking. HCAL has begun planning to re-organize to be synchronized with the overall CMS management structure. HF The full production of the wedges is completed for some time. The 2004 test beam work has established the radioactive source calibration system for HF works at the 5 % level or better and a note is completed. The calibration of the complete HF is complete. HF is now in the UX cavern and will be hooked up and read out as soon as the services are available. HE The two HE calorimeters are installed and an initial calibration has been established. In the MTCC the HE was read out and muon data was observed. Event b...

  11. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    P. De Barbaro and J. Mans.

    2013-01-01

      After the successful operation of the HCAL sub-detector during the proton-proton run in 2012 and heavy-ion run at the beginning of 2013, the group is now focusing on the following four LS1 tasks: ·       Replacement of present, thick-window, single-anode photomultipliers on HF with new, thin-window, multi-anode PMTs. The replacement of photomultipliers will reduce rate of punch-through window hits. All needed PMTs and baseboards have been delivered to CERN. A quality control station has been set up in B904. ·       Replacement of boards responsible for clock distribution in all HBHE and HO Clock and Control Modules (CCMs).  CCMs reside in each Readout Box and are only accessible when the CMS detector is open.  The installation of new CCMs will allow us to eliminate data loss caused by single-event upsets (SEUs) experienced during the 2011&ndash...

  12. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    Central Calorimeter (HB/HE/HO) Photodetectors The main activity of the HCAL group during the present shutdown is the replacement of a small fraction of the Central Calorimeter (HB/HE/HO) photodetectors -- the Hybrid Photo-Detectors (HPDs). During the MTCC of 2006 it was established that all HPDs exhibit a low rate of discharge generating large random pulses. This behaviour persists at the full CMS field. However, at relatively low fields (0.5 Tesla) this discharge rate increases dramatically and becomes very large for a fraction of the HPDs. The HO HPDs which sit in the gap of the return yoke are thus adversly affected. These discharge pulses have been labelled "HPD noise" (which must be distinguished from low level electronic noise which manifests itself as pedestal noise for all HPD readout channels). Additional intermediate level noise can be generated by ion-feedback arising from thermal and field emission electrons. Ion feedback noise never exceeds the equivalent of few 10s of GeV, the...

  13. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    Andris Skuja

    During the last 3 months HCAL has concentrated on ensuring that as many channels are operational as possible for the CRAFT startup. The Data Concentrator Cards (DCCs) for the entire readout path are in the process of being replaced.  HCAL has participated in all midweek global runs during the present startup and is ready to participate in CRAFT during July. Operations and Online The baseline goals of the first mid-week global runs after the winter shutdown were to re-establish the ability to take data in global running, to verify that the detector noise level was comparable to that measured at end of CRAFT 2008, and to finalize the HV settings for data taking. Commissioning of pedestal and laser data taking in orbit gaps started very soon thereafter. Now the orbit gap data are one of the main tools HCAL shifters use to verify that the detector is properly configured and is taking quality data. In March, a new zero suppression (ZS) scheme was deployed in the HTR firmware and commissioned in local ...

  14. Design of a test station for the CMS HCAL waveshifter/waveguide fiber system

    CERN Document Server

    Baumbaugh, B; Kozminski, J; Lu, Q; Ruchti, R C; Wayne, M; Budd, H S; De Barbaro, P; Skup, E

    1998-01-01

    A test station has been designed and is under construction to test the quality of assembled waveguide to waveshifter fiber to be used in the scintillating tile calorimeter for the Compact Moun Solenoid (CMS) Hadron Calorimeter $9 (HCAL). The test station consists of a light tight enclosure 6.8 meters long with the ability to move a light source over almost 6 meters of fiber. Data acquisition hardware and software are under development to analyze the quality $9 of the fiber as well as motor control hardware and software to operate the moveable light source. The design and performance expectations of the test station will be presented. (6 refs).

  15. The CMS Outer HCAL SiPM Upgrade

    CERN Document Server

    Lobanov, Artur

    2015-01-01

    The CMS Outer Hadron Calorimeter (HO) is the first large scale hadron collider detector to use SiPMs. By late January 2014 the installation of 1656 of 2376 channels was completed. The HO readout system provides for active temperature stabilization of the SiPMs to less than 0.1$^\\circ$C using Peltier coolers, temperature measurement, and software feedback. Each channel has independently controlled bias voltage with a resolution of 25~mV. Each SiPM is read out by 40~MHz QIE ADCs. We report on the system design, schedule and progress. The next phase for the detector is commissioning during 2014 before the 2015 LHC run. We report on the status of commissioning and plans for operation. We discuss the calibration strategy with local cosmic ray runs using the HO's self trigger ability. We discuss the plans for a global CMS operations run in November 2014.

  16. Upgrade plans for hadron calorimeter in the CMS detector

    International Nuclear Information System (INIS)

    Dugad, Shashikant R.

    2010-01-01

    The Large Hadron Collider (LHC) is expected to undergo upgrades in two phases in next decade. Luminosity at the completion of the second phase is expected to increase by an order of magnitude to 10 35 /cm 2 s. The upgrade of the CMS Hadron Calorimeter (HCAL) is being planned to sustain an increased dose of radiation and challenges arising from occupancy rate due to higher luminosity. Replacement of existing photo readout device by silicon photomultipliers is being planned for the HCAL. Detailed studies performed on this device are presented. Plans on the upgrade of the front-end electronics, DAQ, trigger, and the active elements in some part of the detector will be discussed in detail.

  17. The CMS HGCAL detector for HL-LHC upgrade

    CERN Document Server

    Martelli, Arabella

    2017-01-01

    The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine structure of showers can be measured and used to enhance pileup rejection and particle identification, whilst still achieving good energy resolution. The ECAL and a large fraction of HCAL will be based on hexagonal silicon sensors of 0.5 - 1 cm$^2$ cell size, with the remainder of the HCAL based on highly-segmented scintillators with SiPM readout. The intrinsic high-precision timing capabilities of the silicon sensors wi...

  18. The CMS High Granularity Calorimeter for HL-LHC

    CERN Document Server

    Mastrolorenzo, Luca

    2017-01-01

    The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine structure of showers can be measured and used to enhance pileup rejection and particle identification, whilst still achieving good energy resolution. The ECAL and a large fraction of HCAL will be based on hexagonal silicon sensors of 0.5 - 1 cm$^2$ cell size, with the remainder of the HCAL based on highly-segmented scintillators with SiPM readout. The intrinsic high-precision timing capabilities of the silicon sensors wi...

  19. The CMS High Granularity Calorimeter for the High Luminosity LHC

    CERN Document Server

    Sauvan, Jean-baptiste

    2017-01-01

    The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine structure of showers can be measured and used to enhance pileup rejection and particle identification, whilst still achieving good energy resolution. The ECAL and a large fraction of HCAL will be based on hexagonal silicon sensors of 0.5 - 1 cm$^2$ cell size, with the remainder of the HCAL based on highly-segmented scintillators with silicon photomultiplier (SiPM) readout. The intrinsic high-precision timing capabilities...

  20. Design and Performance of the CMS Pixel Detector Readout Chip

    CERN Document Server

    Kästli, H C; Erdmann, W; Hörmann, C; Horisberger, R P; Kotlinski, D; Meier, B; Hoermann, Ch.

    2006-01-01

    The readout chip for the CMS pixel detector has to deal with an enormous data rate. On-chip zero suppression is inevitable and hit data must be buffered locally during the latency of the first level trigger. Dead-time must be kept at a minimum. It is dominated by contributions coming from the readout. To keep it low an analog readout scheme has been adopted where pixel addresses are analog coded. We present the architecture of the final CMS pixel detector readout chip with special emphasis on the analog readout chain. Measurements of its performance are discussed.

  1. The CMS HGCAL detector for the HL-LHC upgrade

    CERN Document Server

    Steen, Arnaud

    2017-01-01

    The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine structure of showers can be measured and used to enhance pileup rejection and particle identification, whilst still achieving good energy resolution. The ECAL and a large fraction of HCAL will be based on hexagonal silicon sensors of 0.5 - 1 cm$^2$ cell size, with the remainder of the HCAL based on highly-segmented scintillators with SiPM readout. The intrinsic high-precision timing capabilities of the silicon sensors wi...

  2. Search for Supersymmetric Top-Quark Partners Using Support Vector Machines and Upgrade of the Hadron Calorimeter Front-End Readout Control System at CMS

    CERN Document Server

    Sahin, Mehmet Ozgur; Schleper, Peter

    2017-01-01

    In this thesis a search for direct pair production of supersymmetric top-quark partners aswell as work on the upgrade of the front-end readout controller of the Hadron Calorimeter(HCAL) of the Compact Muon Solenoid (CMS) experiment are presented.The most appealing extension of the Standard Model (SM) is supersymmetry (SUSY), relating the integer spin (bosons) and half-integer spin elementary particles (fermions). Supersymmetric top-quark partners (t) around and below the TeV energy scale offer a solution to thehierarchy problem. Furthermore, R-parity conserving SUSY models propose a cold dark matter candidate in the form of stable lightest supersymmetric particles, e.g. lightest neutralinos(χ0 ).The analysis performed in this thesis is a search for top-squark pair production in a final state consisting of a single isolated lepton, jets, among which at least one is tagged asbottom-quark jet, and large missing transverse energy at the CMS experiment at the CERNLarge Hadron Collider (LHC) with 8 TeV center-of-...

  3. Development of a MicroTCA Carrier Hub for CMS at HL-LHC

    International Nuclear Information System (INIS)

    Dimitriyev, M; Hazen, E; Wu, S X; Rohlf, J

    2010-01-01

    We are developing a Micro TCA Carrier Hub card which provides timing, control and data acquisition functions in a Micro TCA crate for HL-LHC readout electronics. This module may be mounted in the primary or redundant MCH slot in a Micro TCA crate, and distributes low-jitter LHC RF clock and encoded fast timing signals to up to 12 AMC modules. In addition, it receives buffer status signals and DAQ data at up to 600 MBytes/sec from each AMC. The prototype module is built on a commercial MCH base board with a custom mezzanine board stack. The latest Xilinx(R) Virtex(R)-6 FPGA are used to provide a clear upgrade path. Prototype modules have been developed for a CMS HCAL test beam in summer 2010. We describe the specifications of the module, its application in a Micro TCA system beyond CMS HCAL, and our experience in commissioning the module for the test beam.

  4. Development of a MicroTCA Carrier Hub for CMS at HL-LHC

    CERN Document Server

    Dimitriyev, M; Wu, S X; Rohlf, J; 10.1088/1748-0221/5/12/C12042

    2010-01-01

    We are developing a Micro TCA Carrier Hub card which provides timing, control and data acquisition functions in a Micro TCA crate for HL-LHC readout electronics. This module may be mounted in the primary or redundant MCH slot in a Micro TCA crate, and distributes low-jitter LHC RF clock and encoded fast timing signals to up to 12 AMC modules. In addition, it receives buffer status signals and DAQ data at up to 600 MBytes/sec from each AMC. The prototype module is built on a commercial MCH base board with a custom mezzanine board stack. The latest Xilinx® Virtex®-6 FPGA are used to provide a clear upgrade path. Prototype modules have been developed for a CMS HCAL test beam in summer 2010. We describe the specifications of the module, its application in a Micro TCA system beyond CMS HCAL, and our experience in commissioning the module for the test beam

  5. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    P. De Barbaro

    2011-01-01

    HCAL operated very efficiently through the first three months of LHC operation, with the percentage of good channels remaining high (> 99.4%). A single, exceptional loss of ~15 pb-1 of good data was caused by the failure of an AC/DC power converter which provided low voltage to half of HE-plus Readout Boxes (RBXs). The supply was replaced and the failure is under investigation by the manufacturer. One major operation problem is the occasional loss of data from a single RBX. While in 2010 these incidents occurred roughly once per week, the rate of RBX data loss cases has increased substantially in 2011. Recent studies have shown that the rate of these incidents is strongly correlated with the collision rate, with on average one incident per 10 pb-1 of integrated luminosity. In order to mitigate this problem, HCAL has introduced an automatic reset of the RBX. With this reset, full operation is restored within about one minute. We believe that the final fix of the problem will require access to all the...

  6. The CMS Outer HCAL SiPM Upgrade

    CERN Document Server

    CMS Collaboration

    2014-01-01

    The CMS Outer Hadron Calorimeter (HO) is the first large scale hadron collider detector to use SiPMs. By late January 2014 the installation of 1656 of 2376 channels was completed. The HO readout system provides for active temperature stabilisation of the SiPMs to less than 0.1$^\\circ$C using Peltier coolers, temperature measurement, and software feedback. Each channel has independently controlled bias voltage with a resolution of 25mV. Each SiPM is read out by 40MHz QIE ADCs. We report on the system design, schedule and progress. The next phase for the detector is commissioning during 2014 before the 2015 LHC run. We report on the status of commissioning and plans for operation. We discuss the calibration strategy with local cosmic ray runs using the HO's self trigger ability.

  7. Comparison between two possible CMS Barrel Muon Readout Architectures

    International Nuclear Information System (INIS)

    Aguayo, P.; Barcala, J.M.; Molinero, A.; Pablos, J.L.; Willmott, C.; Alberdi, J.; Marin, J.; Navarrete, J.; Romero, L.

    1997-01-01

    A comparison between two possible readout arquitectures for the CMS muon barrel readout electronics is presented, including various aspects like costs, reliability, installation, staging and maintenance. A review of the present baseline architecture is given in the appendix. (Author)

  8. Installation of CMS EB (ECAL Barrel) Supermodules 5 and 13 inside HB+ (HCAL Barrel) on 26/27 April 2006

    CERN Multimedia

    Ken Bell, RAL

    2006-01-01

    The first two barrel "supermodules" of the CMS Electromagnetic Calorimeter (ECAL) have been inserted into the barrel hadron calorimeter (HCAL) in the CMS experimental hall (called SX5) in Cessy in preparation for the forthcoming magnet test and cosmic challenge (MTCC). Each of the two supermodules contains 1700 lead tungstate crystals in glass-fibre alveolar support structures, with associated avalanche photodiodes (APDs, for scintillation light detection), electronics and cooling system. See also the document CMS-PHO-OREACH-2006-019. The first two pictures show the two supermodules in their final position. Fig. 3: the "enfourneur" in position on the HB Cradle. Fig. 4: supermodule n. 5 and extension rails being lifted to the enforneur. Figs. 5-6: supermodule approaching the enforneur. Fig. 7: rotating the Enfourneur to the correct phi direction Figs. 8-9: aligning the extension rails with the rails inside HB and view from inside HB, once the rails are aligned. Figs. 10-12: insertion of supermodule n. 5. Fig. ...

  9. The CMS High-Granularity Calorimeter (HGCAL) for Operation at the High-Luminosity LHC

    CERN Document Server

    Pitters, Florian Michael

    2017-01-01

    The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine structure of showers can be measured and used to enhance pileup rejection and particle identification, whilst still achieving good energy resolution. The ECAL and a large fraction of HCAL will be based on hexagonal silicon sensors of 0.5 - 1 cm^2 cell size, with the remainder of the HCAL based on highly-segmented scintillators with SiPM readout. The intrinsic high-precision timing capabilities of the silicon sensors will...

  10. The CMS High Granularity Calorimeter for the High Luminosity LHC

    Science.gov (United States)

    Sauvan, J.-B.

    2018-02-01

    The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine structure of showers can be measured and used to enhance pileup rejection and particle identification, whilst still achieving good energy resolution. The ECAL and a large fraction of HCAL will be based on hexagonal silicon sensors of 0.5-1 cm2 cell size, with the remainder of the HCAL based on highly-segmented scintillators with silicon photomultiplier (SiPM) readout. The intrinsic high-precision timing capabilities of the silicon sensors will add an extra dimension to event reconstruction, especially in terms of pileup rejection.

  11. Synchronization and Timing in CMS HCAL

    CERN Document Server

    Baiatian, G; Emeliantchik, Igor; Massolov, V; Shumeiko, Nikolai; Stefanovich, R; Damgov, Jordan; Dimitrov, Lubomir; Genchev, Vladimir; Piperov, Stefan; Vankov, Ivan; Litov, Leander; Bencze, Gyorgy; Laszlo, Andras; Pal, Andras; Vesztergombi, Gyorgy; Zálán, Peter; Fenyvesi, Andras; Bawa, Harinder Singh; Beri, Suman Bala; Bhatnagar, Vipin; Kaur, Manjit; Kohli, Jatinder Mohan; Kumar, Arun; Singh, Jas Bir; Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Chendvankar, Sanjay; Dugad, Shashikant; Kalmani, Suresh Devendrappa; Katta, S; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Patil, Mandakini Ravindra; Reddy, L; Satyanarayana, B; Sharma, Seema; Sudhakar, Katta; Verma, Piyush; Hashemi, Majid; Mohammadi-Najafabadi, M; Paktinat, S; Golutvin, Igor; Kalagin, Vladimir; Kosarev, Ivan; Ladygin, Vladimir; Mescheryakov, G; Moissenz, P; Petrosian, A; Sergeyev, S; Smirnov, Vitaly; Vishnevskiy, Alexander; Volodko, Anton; Zarubin, Anatoli; Gavrilov, Vladimir; Gershtein, Yuri; Ilyina, N; Kaftanov, Vitali; Kisselevich, I; Kolossov, V; Krokhotin, Andrey; Kuleshov, Sergey; Litvintsev, Dmitri; Ulyanov, A; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Demianov, A; Gribushin, Andrey; Kodolova, Olga; Petrushanko, Sergey; Sarycheva, Ludmila; Teplov, V; Vardanyan, Irina; Yershov, A; Abramov, Victor; Goncharov, Petr; Kalinin, Alexey; Khmelnikov, Alexander; Korablev, Andrey; Korneev, Yury; Krinitsyn, Alexander; Kryshkin, V; Lukanin, Vladimir; Pikalov, Vladimir; Ryazanov, Anton; Talov, Vladimir; Turchanovich, L; Volkov, Alexey; Camporesi, Tiziano; De Visser, Theo; Vlassov, E; Aydin, Sezgin; Bakirci, Mustafa Numan; Cerci, Salim; Dumanoglu, Isa; Eskut, Eda; Kayis-Topaksu, A; Koylu, S; Kurt, Pelin; Onengüt, G; Ozkurt, Halil; Polatoz, A; Sogut, Kenan; Topakli, Huseyin; Vergili, Mehmet; Yetkin, Taylan; Cankocak, Kerem; Esendemir, Akif; Gamsizkan, Halil; Güler, M; Ozkan, Cigdem; Sekmen, Sezen; Serin-Zeyrek, M; Sever, Ramazan; Yazgan, Efe; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Gülmez, Erhan; Isiksal, Engin; Kaya, Mithat; Ozkorucuklu, Suat; Levchuk, Leonid; Sorokin, Pavel; Senchyshyn, Vitaliy; Hauptman, John M; Abdullin, Salavat; Elias, John E; Elvira, D; Freeman, Jim; Green, Dan; Los, Serguei; O'Dell, Vivian; Ronzhin, Anatoly; Suzuki, Ichiro; Vidal, Richard; Whitmore, Juliana; Arcidy, M; Hazen, Eric; Heering, Arjan Hendrix; Lawlor, C; Lazic, Dragoslav; Machado, Emanuel; Rohlf, James; Varela, F; Wu, Shouxiang; Baden, Drew; Bard, Robert; Eno, Sarah Catherine; Grassi, Tullio; Jarvis, Chad; Kellogg, Richard G; Kunori, Shuichi; Mans, Jeremy; Skuja, Andris; Podrasky, V; Sanzeni, Christopher; Winn, Dave; Akgun, Ugur; Ayan, S; Duru, Firdevs; Merlo, Jean-Pierre; Mestvirishvili, Alexi; Miller, Michael; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Schmidt, Ianos; Akchurin, Nural; Carrell, Kenneth Wayne; Gumus, Kazim; Kim, Heejong; Spezziga, Mario; Thomas, Ray; Wigmans, Richard; Baarmand, Marc M; Mermerkaya, Hamit; Ralich, Robert; Vodopiyanov, Igor; Kramer, Laird; Linn, Stephan; Markowitz, Pete; Cushman, Priscilla; Ma, Yousi; Sherwood, Brian; Cremaldi, Lucien Marcus; Reidy, Jim; Sanders, David A; Karmgard, Daniel John; Ruchti, Randy; Fisher, Wade Cameron; Tully, Christopher; Bodek, Arie; De Barbaro, Pawel; Budd, Howard; Chung, Yeon Sei; Haelen, T; Hagopian, Sharon; Hagopian, Vasken; Johnson, K; Barnes, Virgil E; Laasanen, Alvin T

    2006-01-01

    The synchronization and timing of the hadron calorimeter (HCAL) for the Compact Muon Solenoid has been extensively studied with test beams at CERN during the period 2003-4, including runs with 40 MHz structured beam. The relative phases of the signals from different calorimeter segments are timed to 1 ns accuracy using a laser and equalized using programmable delay settings in the front-end electronics. The beam was used to verify the timing and to map out the entire range of pulse shapes over the 25 ns interval between beam crossings. These data were used to make detailed measurements of energy-dependent time slewing effects and to tune the electronics for optimal performance.

  12. Readout chip for the CMS pixel detector upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Rossini, Marco, E-mail: marco.rossini@phys.ethz.ch

    2014-11-21

    For the CMS experiment a new pixel detector is planned for installation during the extended shutdown in winter 2016/2017. Among the changes of the detector modified front end electronics will be used for higher efficiency at peak luminosity of the LHC and faster readout. The first prototype versions of the new readout chip have been designed and produced. The results of qualification and calibration for the new chip are presented in this paper.

  13. Monitoring the CMS strip tracker readout system

    International Nuclear Information System (INIS)

    Mersi, S; Bainbridge, R; Cripps, N; Fulcher, J; Wingham, M; Baulieu, G; Bel, S; Delaere, C; Drouhin, F; Mirabito, L; Cole, J; Giassi, A; Gross, L; Hahn, K; Nikolic, M; Tkaczyk, S

    2008-01-01

    The CMS Silicon Strip Tracker at the LHC comprises a sensitive area of approximately 200 m 2 and 10 million readout channels. Its data acquisition system is based around a custom analogue front-end chip. Both the control and the readout of the front-end electronics are performed by off-detector VME boards in the counting room, which digitise the raw event data and perform zero-suppression and formatting. The data acquisition system uses the CMS online software framework to configure, control and monitor the hardware components and steer the data acquisition. The first data analysis is performed online within the official CMS reconstruction framework, which provides many services, such as distributed analysis, access to geometry and conditions data, and a Data Quality Monitoring tool based on the online physics reconstruction. The data acquisition monitoring of the Strip Tracker uses both the data acquisition and the reconstruction software frameworks in order to provide real-time feedback to shifters on the operational state of the detector, archiving for later analysis and possibly trigger automatic recovery actions in case of errors. Here we review the proposed architecture of the monitoring system and we describe its software components, which are already in place, the various monitoring streams available, and our experiences of operating and monitoring a large-scale system

  14. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    HCAL installation and commissioning is approaching completion. Work continues on commissioning of HE-, HF- and the minus wheels of HO. We expect that all commissioning will be completed by mid-March. HCAL commissioning is interleaved with integration of HCAL and the Global Calorimeter Trigger (GCT). HCAL is attempting to take data using the HPD self-trigger as part of the GCT trigger path. Initial attempts in mid-February have not succeeded. Work continues on HCAL and the GCT. HPD lifetimes at 4 Tesla are being measured in Princeton. After more than a month of testing in a 4 Tesla field there are no sur¬prises. As the lifetime measurements proceed, the HPD response at intermediate fields of 1 Tesla will be verified and analyzed. Work also continues on HCAL calibration and DCS/DSS at Point 5. More details for some of the subsystems are presented in what follows. HE HE plus The cooling system of HE+ is functional now. The HE+ final connections to the LV system are complete. LV and HV tests to ev...

  15. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Spalding and A. Skuja

    2010-01-01

    Splash and Collision Data HCAL recorded the beam-on-collimator (splash) and the first collision data in November and December 2009, and provided triggers to CMS with the forward calorimeter, HF. Splash events were used to improve the energy inter-calibration of the HB and HE channels, with the basic assumption that the energy deposited in the detector by the large flux of muons that passed through in splash events was a smooth function in eta and phi. The new HB and HE calibration coefficients were applied prior to the collision data taking. For HO, a similar analysis is being finalized. Splash events were also used to determine the relative timing between channels in HB and HE, and new delay settings were calculated based on splashes from one beam, applied and verified with the splash events from the other beam. During Fall 2009, the HF technical trigger was improved in order to be effectively used as one of the main CMS triggers during the collision data taking. Collisions were successfully recorded by all...

  16. Search for supersymmetric top-quark partners using support vector machines and upgrade of the hadron calorimeter front-end readout control system at CMS

    Energy Technology Data Exchange (ETDEWEB)

    Sahin, Mehmet Oezguer

    2017-04-15

    In this thesis a search for direct pair production of supersymmetric top-quark partners as well as work on the upgrade of the front-end readout controller of the Hadron Calorimeter (HCAL) of the Compact Muon Solenoid (CMS) experiment are presented. The most appealing extension of the Standard Model (SM) is supersymmetry (SUSY), relating the integer spin (bosons) and half-integer spin elementary particles (fermions). Supersymmetric top-quark partners (t) around and below the TeV energy scale offer a solution to the hierarchy problem. Furthermore, R-parity conserving SUSY models propose a cold dark matter candidate in the form of stable lightest supersymmetric particles, e.g. lightest neutralinos (χ{sup 0}). The analysis performed in this thesis is a search for top-squark pair production in a final state consisting of a single isolated lepton, jets, among which at least one is tagged as bottom-quark jet, and large missing transverse energy at the CMS experiment at the CERN Large Hadron Collider (LHC) with 8 TeV center-of-mass energy. A new Support Vector Machines (SVM) High-Energy Physics interface (SVM-HINT) software is introduced to classify signal events originating from new physics processes and the SM background. SVM-HINT is enhanced with a novel statistical significance based optimization algorithm providing a state-of-the-art classification power. Monte Carlo simulations are used in the training and optimization procedure, and high signal purity search regions are determined in the search for top-squark pair production. The background event yields in each search region are predicted using a data-driven background estimation method. The results are interpreted within a simplified model assuming a branching ratio of 100% to t → tχ{sup 0}. No significant discrepancy between the data and the SM predictions has been observed. Exclusion limits were derived to constrain the m{sub t} and m{sub χ{sup 0}} of the investigated simplified model. The sensitivity of the

  17. Search for supersymmetric top-quark partners using support vector machines and upgrade of the hadron calorimeter front-end readout control system at CMS

    International Nuclear Information System (INIS)

    Sahin, Mehmet Oezguer

    2017-04-01

    In this thesis a search for direct pair production of supersymmetric top-quark partners as well as work on the upgrade of the front-end readout controller of the Hadron Calorimeter (HCAL) of the Compact Muon Solenoid (CMS) experiment are presented. The most appealing extension of the Standard Model (SM) is supersymmetry (SUSY), relating the integer spin (bosons) and half-integer spin elementary particles (fermions). Supersymmetric top-quark partners (t) around and below the TeV energy scale offer a solution to the hierarchy problem. Furthermore, R-parity conserving SUSY models propose a cold dark matter candidate in the form of stable lightest supersymmetric particles, e.g. lightest neutralinos (χ"0). The analysis performed in this thesis is a search for top-squark pair production in a final state consisting of a single isolated lepton, jets, among which at least one is tagged as bottom-quark jet, and large missing transverse energy at the CMS experiment at the CERN Large Hadron Collider (LHC) with 8 TeV center-of-mass energy. A new Support Vector Machines (SVM) High-Energy Physics interface (SVM-HINT) software is introduced to classify signal events originating from new physics processes and the SM background. SVM-HINT is enhanced with a novel statistical significance based optimization algorithm providing a state-of-the-art classification power. Monte Carlo simulations are used in the training and optimization procedure, and high signal purity search regions are determined in the search for top-squark pair production. The background event yields in each search region are predicted using a data-driven background estimation method. The results are interpreted within a simplified model assuming a branching ratio of 100% to t → tχ"0. No significant discrepancy between the data and the SM predictions has been observed. Exclusion limits were derived to constrain the m_t and m_χ_"0 of the investigated simplified model. The sensitivity of the previous searches with

  18. Optical readout and control systems for the CMS tracker

    CERN Document Server

    Troska, Jan K; Faccio, F; Gill, K; Grabit, R; Jareno, R M; Sandvik, A M; Vasey, F

    2003-01-01

    The Compact Muon Solenoid (CMS) Experiment will be installed at the CERN Large Hadron Collider (LHC) in 2007. The readout system for the CMS Tracker consists of 10000000 individual detector channels that are time-multiplexed onto 40000 unidirectional analogue (40 MSample /s) optical links for transmission between the detector and the 65 m distant counting room. The corresponding control system consists of 2500 bi-directional digital (40 Mb/s) optical links based as far as possible upon the same components. The on-detector elements (lasers and photodiodes) of both readout and control links will be distributed throughout the detector volume in close proximity to the silicon detector elements. For this reason, strict requirements are placed on minimal package size, mass, power dissipation, immunity to magnetic field, and radiation hardness. It has been possible to meet the requirements with the extensive use of commercially available components with a minimum of customization. The project has now entered its vol...

  19. The CMS silicon strip tracker and its electronic readout

    International Nuclear Information System (INIS)

    Friedl, M.

    2001-05-01

    The Large Hadron Collider (LHC) at CERN (Geneva, CH) will be the world's biggest accelerator machine when operation starts in 2006. One of its four detector experiments is the Compact Muon Solenoid (CMS), consisting of a large-scale silicon tracker and electromagnetic and hadron calorimeters, all embedded in a solenoidal magnetic field of 4 T, and a muon system surrounding the magnet coil. The Silicon Strip Tracker has a sensitive area of 206m 2 with 10 million analog channels which are read out at the collider frequency of 40 MHz. The building blocks of the CMS Tracker are the silicon sensors, APV amplifier ASICs, supporting front-end ASICs, analog and digital optical links as well as data processors and control units in the back-end. Radiation tolerance, readout speed and the huge data volume are challenging requirements. The charge collection in silicon detectors was modeled, which is discussed as well as the concepts of readout amplifiers with respect to the LHC requirements, including the deconvolution method of fast pulse shaping, electronic noise constraints and radiation effects. Moreover, extensive measurements on prototype components of the CMS Tracker and different versions of the APV chip in particular were performed. There was a significant contribution to the construction of several detector modules, characterized them in particle beam tests and quantified radiation induced effects on the APV chip and on silicon detectors. In addition, a prototype of the analog optical link and the analog performance of the back-end digitization unit were evaluated. The results are very encouraging, demonstrating the feasibility of the CMS Silicon Strip Tracker system and motivating progress towards the construction phase. (author)

  20. Design, performance, and calibration of the CMS hadron-outer calorimeter

    International Nuclear Information System (INIS)

    Abdullin, S.; Gavrilov, V.; Ilyina, N.; Kaftanov, V.; Kisselevich, I.; Kolossov, V.; Krokhotin, A.; Kuleshov, S.; Pozdnyakov, A.; Safronov, G.; Semenov, S.; Stolin, V.; Ulyanov, A.; Abramov, V.; Goncharov, P.; Kalinin, A.; Khmelnikov, A.; Korablev, A.; Korneev, Y.; Krinitsyn, A.; Kryshkin, V.; Lukanin, V.; Pikalov, V.; Ryazanov, A.; Talov, V.; Turchanovich, L.; Volkov, A.; Acharya, B.; Aziz, T.; Banerjee, Sudeshna; Banerjee, Sunanda; Bose, S.; Chendvankar, S.; Deshpande, P.V.; Dugad, S.; Ganguli, S.N.; Guchait, M.; Gurtu, A.; Kalmani, S.; Krishnaswamy, M.R.; Maity, M.; Majumder, G.; Mazumdar, K.; Mondal, N.; Nagaraj, P.; Narasimham, V.S.; Patil, M.; Reddy, L.; Satyanarayana, B.; Sharma, S.; Sudhakar, K.; Tonwar, S.; Verma, P.; Adam, N.; Fisher, W.; Halyo, V.; Hunt, A.; Jones, J.; Laird, E.; Landsberg, G.; Marlow, D.; Tully, C.; Werner, J.; Adams, M.; Bard, R.; Burchesky, K.; Qian, W.; Akchurin, N.; Berntzon, L.; Carrell, K.; Guemues, K.; Jeong, C.; Kim, H.; Lee, S.W.; Popescu, S.; Roh, Y.; Spezziga, M.; Thomas, R.; Volobouev, I.; Wigmans, R.; Yazgan, E.; Akgun, U.; Albayrak, E.; Ayan, S.; Clarida, W.; Debbins, P.; Duru, F.; Ingram, D.; Merlo, J.P.; Mestvirishvili, A.; Miller, M.; Moeller, A.; Norbeck, E.; Olson, J.; Onel, Y.; Ozok, F.; Schmidt, I.; Yetkin, T.; Anderson, E.W.; Hauptman, J.; Antchev, G.; Arcidy, M.; Hazen, E.; Heister, A.; Lawlor, C.; Lazic, D.; Machado, E.; Posch, C.; Rohlf, J.; Sulak, L.; Varela, F.; Wu, S.X.; Aydin, S.; Bakirci, M.N.; Cerci, S.; Dumanoglu, I.; Erturk, S.; Eskut, E.; Kayis-Topaksu, A.; Onengut, G.; Ozkurt, H.; Polatoz, A.; Sogut, K.; Topakli, H.; Vergili, M.; Baarmand, M.; Mermerkaya, H.; Ralich, R.M.; Vodopiyanov, I.; Babich, K.; Golutvin, I.; Kalagin, V.; Kosarev, I.; Ladygin, V.; Mescheryakov, G.; Moissenz, P.; Petrosyan, A.; Rogalev, E.; Smirnov, V.; Vishnevskiy, A.; Volodko, A.; Zarubin, A.; Baden, D.; Eno, S.; Grassi, T.; Jarvis, C.; Kellogg, R.; Kunori, S.; Skuja, A.; Wang, L.; Wetstein, M.; Barnes, V.; Laasanen, A.; Pompos, A.; Bawa, H.; Beri, S.; Bhandari, V.; Bhatnagar, V.; Kaur, M.; Kohli, J.; Kumar, A.; Singh, B.; Singh, J.B.; Baiatian, G.; Sirunyan, A.; Bencze, G.; Laszlo, A.; Pal, A.; Vesztergombi, G.; Zalan, P.; Bhatti, A.; Bodek, A.; Budd, H.; Chung, Y.; Barbaro, P. de; Haelen, T.; Bose, T.; Esen, S.; Vanini, A.; Camporesi, T.; Visser, T. de; Efthymiopoulos, I.; Cankocak, K.; Cremaldi, L.; Reidy, J.; Sanders, D.A.; Cushman, P.; Ma, Y.; Sherwood, B.; Damgov, J.; Piperov, S.; Deliomeroglu, M.; Guelmez, E.; Isiksal, E.; Kaya, M.; Kaya, O.; Ozkorucuklu, S.; Sonmez, N.; Demianov, A.; Ershov, A.; Gribushin, A.; Kodolova, O.; Petrushanko, S.; Sarycheva, L.; Teplov, K.; Vardanyan, I.; Diaz, J.; Gaultney, V.; Kramer, L.; Linn, S.; Lobolo, L.; Markowitz, P.; Martinez, G.; Dimitrov, L.; Genchev, V.; Vankov, I.; Elias, J.; Elvira, D.; Freeman, J.; Green, D.; Los, S.; Ronzhin, A.; Sergeyev, S.; Suzuki, I.; Vidal, R.; Whitmore, J.; Emeliantchik, I.; Mossolov, V.; Shumeiko, N.; Stefanovich, R.; Fenyvesi, A.; Gamsizkan, H.; Murat Gueler, A.; Ozkan, C.; Sekmen, S.; Serin, M.; Sever, R.; Zeyrek, M.; Gleyzer, S.; Hagopian, S.; Hagopian, V.; Johnson, K.; Grinev, B.; Lubinsky, V.; Senchishin, V.; Hashemi, M.; Mohammadi-Najafabadi, M.; Paktinat, S.; Heering, A.; Karmgard, D.; Ruchti, R.; Levchuk, L.; Sorokin, P.; Litvintsev, D.; Mans, J.; Penzo, A.; Podrasky, V.; Sanzeni, C.; Winn, D.; Vlassov, E.

    2008-01-01

    The Outer Hadron Calorimeter (HCAL HO) of the CMS detector is designed to measure the energy that is not contained by the barrel (HCAL HB) and electromagnetic (ECAL EB) calorimeters. Due to space limitation the barrel calorimeters do not contain completely the hadronic shower and an outer calorimeter (HO) was designed, constructed and inserted in the muon system of CMS to measure the energy leakage. Testing and calibration of the HO was carried out in a 300 GeV/c test beam that improved the linearity and resolution. HO will provide a net improvement in missing E T measurements at LHC energies. Information from HO will also be used for the muon trigger in CMS. (orig.)

  1. Design, performance, and calibration of the CMS hadron-outer calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Abdullin, S.; Gavrilov, V.; Ilyina, N.; Kaftanov, V.; Kisselevich, I.; Kolossov, V.; Krokhotin, A.; Kuleshov, S.; Pozdnyakov, A.; Safronov, G.; Semenov, S.; Stolin, V.; Ulyanov, A. [ITEP, Moscow (Russian Federation); Abramov, V.; Goncharov, P.; Kalinin, A.; Khmelnikov, A.; Korablev, A.; Korneev, Y.; Krinitsyn, A.; Kryshkin, V.; Lukanin, V.; Pikalov, V.; Ryazanov, A.; Talov, V.; Turchanovich, L.; Volkov, A. [IHEP, Protvino (Russian Federation); Acharya, B.; Aziz, T.; Banerjee, Sudeshna; Banerjee, Sunanda; Bose, S.; Chendvankar, S.; Deshpande, P.V.; Dugad, S.; Ganguli, S.N.; Guchait, M.; Gurtu, A.; Kalmani, S.; Krishnaswamy, M.R.; Maity, M.; Majumder, G.; Mazumdar, K.; Mondal, N.; Nagaraj, P.; Narasimham, V.S.; Patil, M.; Reddy, L.; Satyanarayana, B.; Sharma, S.; Sudhakar, K.; Tonwar, S.; Verma, P. [Tata Inst. of Fundamental Research, Mumbai (India); Adam, N.; Fisher, W.; Halyo, V.; Hunt, A.; Jones, J.; Laird, E.; Landsberg, G.; Marlow, D.; Tully, C.; Werner, J. [Princeton Univ., NJ (United States); Adams, M.; Bard, R.; Burchesky, K.; Qian, W. [Univ. of Illinois, Chicago, IL (United States); Akchurin, N.; Berntzon, L.; Carrell, K.; Guemues, K.; Jeong, C.; Kim, H.; Lee, S.W.; Popescu, S.; Roh, Y.; Spezziga, M.; Thomas, R.; Volobouev, I.; Wigmans, R.; Yazgan, E. [Texas Tech Univ., Lubbock, TX (United States); Akgun, U.; Albayrak, E.; Ayan, S.; Clarida, W.; Debbins, P.; Duru, F.; Ingram, D.; Merlo, J.P.; Mestvirishvili, A.; Miller, M.; Moeller, A.; Norbeck, E.; Olson, J.; Onel, Y.; Ozok, F.; Schmidt, I.; Yetkin, T. [Univ. of Iowa, Iowa City, IA (United States); Anderson, E.W.; Hauptman, J. [Iowa State Univ., Ames, IA (United States); Antchev, G.; Arcidy, M.; Hazen, E.; Heister, A.; Lawlor, C.; Lazic, D.; Machado, E.; Posch, C.; Rohlf, J.; Sulak, L.; Varela, F.; Wu, S.X. [Boston Univ., MA (United States); Aydin, S.; Bakirci, M.N.; Cerci, S.; Dumanoglu, I.; Erturk, S.; Eskut, E.; Kayis-Topaksu, A.; Onengut, G.; Ozkurt, H.; Polatoz, A.; Sogut, K. [and others

    2008-10-15

    The Outer Hadron Calorimeter (HCAL HO) of the CMS detector is designed to measure the energy that is not contained by the barrel (HCAL HB) and electromagnetic (ECAL EB) calorimeters. Due to space limitation the barrel calorimeters do not contain completely the hadronic shower and an outer calorimeter (HO) was designed, constructed and inserted in the muon system of CMS to measure the energy leakage. Testing and calibration of the HO was carried out in a 300 GeV/c test beam that improved the linearity and resolution. HO will provide a net improvement in missing E{sub T} measurements at LHC energies. Information from HO will also be used for the muon trigger in CMS. (orig.)

  2. Test vehicles for CMS HGCAL readout ASIC

    CERN Document Server

    Thienpont, Damien

    2017-01-01

    This paper presents first measurement results of two test vehicles ASIC embedding some building blocks for the future CMS High Granularity CALorimeter (HGCAL) read-out ASIC. They were fabricated in CMOS 130 nm, in order to first design the Analog and Mixed-Signal blocks before going to a complete and complex chip. Such a circuit needs to achieve low noise high dynamic range charge measurement and 20 ps resolution timing capability. The results show good analog performance but with higher noise levels compared to simulations. We present the results of the preamplifiers, shapers and ADCs.

  3. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    The highlight of HCAL operations during the last three months was the CRAFT run. In addition to understanding better the overall HCAL detector operations, we also measured the HPD (Hybrid Photo Detector) response in a magnetic field. In particular, at fields of 0.5T to 3.0T the HPDs exhibit large discharge pulses. Such behaviour is not observed above 3.5T. We determined that about 8 HPDs were not suitable for magnetic field operation in HB and HE. For HO it was found that all HPDs were OK in Ring 0 but an additional 20 (or so) HPDs were marginal for Rings 1 and Rings 2. In addition, the HV of the HPDs for Rings 1 and Rings 2 had to be lowered to 6.5KV (from 8KV) for stable operation. DPG and CRAFT During CRAFT the HCAL DPG focused on developing and testing the tools needed for fast data validation and run certification, and for full integration of all configurations needed to initialize zero suppression (ZS), LUT, etc., .using central run Keys. The display of alarms to HCAL shifters was expanded to inc...

  4. Construction and beam-tests of silicon-tungsten and scintillator-SiPM modules for the CMS High Granularity Calorimeter for HL-LHC

    CERN Document Server

    Chang, Yung-wei

    2018-01-01

    A High Granularity Calorimeter (HGCAL) is being designed to replace the existing endcap calorimeters in CMS for the HL-LHC era. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments, with silicon sensors being chosen for the high-pseudorapidity regions due to their radiation tolerance. The remainder of the HGCAL, in the lower radiation environment, will use plastic scintillator with on-tile SiPM readout. Prototype hexagonal silicon modules, featuring a new Skiroc2-CMS front-end chip, together with a modified version of the scintillator-SiPM CALICE AHCAL, have been built and tested in beams at CERN in 2017. In this poster, we present measurements of noise, calibration, shower shapes and performance with electrons, pions and muons.

  5. The selective read-out processor for the CMS electromagnetic calorimeter

    CERN Document Server

    Girão de Almeida, Nuño Miguel; Faure, Jean Louis; Gachelin, Olivier; Gras, Philippe; Mandjavidze, Irakli; Mur, Michel; Varela, João

    2005-01-01

    This paper describes the selective read-out processor (SRP) proposed for the electromagnetic calorimeter (ECAL) of the Compact Muon Solenoid (CMS) experiment at LHC (CERN). The aim is to reduce raw ECAL data to a level acceptable by the CMS data acquisition (DAQ) system. For each positive level 1 trigger, the SRP is guided by trigger primitive generation electronics to identify ECAL regions with energy deposition satisfying certain programmable criteria. It then directs the ECAL read-out electronics to apply predefined zero suppression levels to the crystal data, depending whether the crystals fall within these regions or not. The main challenges for the SRP are some 200 high speed (1.6 Gbit/s) I/O channels, asynchronous operation at up to 100 kHz level 1 trigger rate, a 5- mu s real-time latency requirement and a need to retain flexibility in choice of selection algorithms. The architecture adopted for the SRP is based on modern parallel optic pluggable modules and high density field programmable gate array ...

  6. Light-to-light readout system of the CMS electromagnetic calorimeter

    CERN Document Server

    Denes, P; Lustermann, W; Mathez, H; Pangaud, P; Walder, J P

    2001-01-01

    For the CMS experiment at the Large Hadron Collider at CERN, an 8OOOO-crysral electromagnetic calorimeter will measure electron and photon energies with high precision over a dynamic range of roughly 16 bits. The readout electronics will be located directly behind the crystals, and must survive a total dose of up to 2x10 Gy along with 5x10**1**3 n/cm**2. A readout chain consisting of a custom wide-range acquisition circuit, commercial ADC and custom optical link for each crystal is presently under construction. An overview of the design is presented, with emphasis on the large-scale fiber communication system. 11 Refs.

  7. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Spalding

    2010-01-01

    The HCAL system operated very reliably in the 2010 running period for both pp and heavy ion collisions, with 99% of channels live (excluding HO ring 2). Since early June, the high voltage for HO ring 2 was turned off in order to preserve the HPDs as long-term spares (see last bulletin). This results in little impact to physics performance in early LHC operation. In HB and HE, one channel was masked as bad in mid-July due to an unstable pedestal. In addition, the bias voltage was reduced for one HPD due to excessive current draw. This HPD continues to operate reliably with only a minor reduction in timing resolution. Overall this represents very stable operation for a long period. There is one operational problem that is proving difficult to trouble-shoot. Occasionally, about once every few days, one readout box (only) will lose synchronization and deliver garbled data. Recovery requires a complete reset of the system. This behavior cannot be reproduced in test setups, but in-situ diagnostics have been develo...

  8. CERN Open Days CMS Posters

    CERN Multimedia

    Davis, Siona Ruth

    2016-01-01

    Themes: 1) You are here (location P5, Cessy) 2) CERN 3) LHC 4) CMS Detector 5) Magnet 6) Subdetectors (Tracker, ECAL, HCAL, Muons) 7) Trigger and Data Acquisition 8) Collaboration 9) Site Geography 10) Construction 11) Lowering and Installation 12) Physics

  9. Development of Digital Readout Electronics for the CMS Tracker

    CERN Document Server

    Corrin, E P

    2002-01-01

    The Compact Muon Solenoid (CMS) is a general-purpose detector, based at CERN in Switzerland, designed to look for new physics in high-energy protonproton collisions provided by the Large Hadron Collider. The CMS tracker has 10 million readout channels being sampled at a rate of 40 MHz, then read out at up to 100 kHz, generating huge volumes of data; it is essential that the system can handle these rates without any of the data being lost or corrupted. The CMS tracker FED processes the data, removing pedestal and common mode-noise, and then performing hit and cluster finding. Strips below threshold are discarded, resulting in a significant reduction in data size. These zero suppressed data are stored in a buffer before being sent to the DAQ. The processing on the FEDs is done using FPGAs. Programmable logic was chosen over custom ASICs because of the lower cost, faster design and verification process, and the ability to easily upgrade the firmware at a later date. This thesis is concerned with the digital read...

  10. Irradiation test of the HCAL Forward and Endcap upgrade electronics at the CHARM facility at CERN

    CERN Document Server

    AUTHOR|(CDS)2068434; Costanza, Francesco; Karakaya, Tugba; Sahin, Mehmet Ozgur; Lincoln, Don; Strobbe, Nadja; Kaminskiy, Alexander; Tlisov, Danila; Wang, Yanchu; Hirschauer, James Francis

    2016-01-01

    In the period October 21 – 28, 2015, the CMS HCAL group did a radiation tolerance study for the Phase I Upgrade HF, HE and HB front end electronics. The test was conducted at the CERN CHARM facility, which is a mixed field radiation facility. No permanent damages were observed. Effects observed during the irradiation are presented.

  11. CMS AWARDS

    CERN Multimedia

    Steven Lowette

    Working under great time pressure towards a common goal in gradual steps can sometimes cause us to forget to take a step back, and celebrate what marvels have been achieved. A general need was felt within CMS to expand the recognition for our young scientists that made outstanding, well recognized and creative contributions to CMS, which served to significantly advance the performance of CMS as a complete and powerful experiment. Therefore, the Collaboration Board endorsed in March 2009 a proposal from the CB Chair and Advisory Group to award each year the newly created "CMS Achievement Award" to fourteen graduate students and postdocs that made exceptional contributions to the Tracker, ECAL, HCAL and Muon subdetectors as well as the TriDAS project, the Commissioning of CMS and the Offline Software and Computing projects. It was also agreed that there was a need to go back in time, and retroactively attribute awards for the years 2007 and 2008 when CMS went from a bare cavern to a detect...

  12. Upgrade of the CMS hardron calorimeter for an upgraded LHC

    OpenAIRE

    Anderson, Jake

    2012-01-01

    The CMS barrel and endcap hadron calorimeters (Hcal) upgrading the current photo-sensors are hybrid photodiodes (HPDs) to meet the demands of the upgraded luminosity of the LHC. A key aspect of the Hcal upgrade is to add longitudinal segmentation to improve background rejection, energy resolution, and electron isolation at L1 trigger. The increased segmentation can be achieved by replacing the HPD's with multi-pixel Geiger-mode avalanche photodiodes. The upgraded electron...

  13. CMS Status

    International Nuclear Information System (INIS)

    Dobrzynski, L.

    2007-01-01

    The status of the construction and installation of CMS detector is reviewed. The 4T magnet is cold since end of February 2006. Its commissioning up to the nominal field started in July 2006 allowing a Cosmic Challenge in which elements of the final detector are involved. All big mechanical pieces equipped with muons chambers have been assembled in the surface hall SX5. Since mid July the detector is closed with commissioned HCAL, two ECAL supermodules and representative elements of the silicon tracker. The trigger system as well as the DAQ are tested. After the achievement of the physics TDR, CMS is now ready for the promising signal hunting. (author)

  14. A Front-End Readout Architecture for the CMS Barrel Muon Detector: A Feasibility Study

    International Nuclear Information System (INIS)

    Aguayo, P.; Alberdi, J.; Barcala, J.M.; Marin, J.; Molinero, A.; Navarrete, J.; Pablos, J.L. de; Romero, L.; Willmot, C.

    1995-01-01

    A feasibility study of a possible architecture for the CMS barrel muon detector readout electronics is presented. some aspects of system reliability are discussed. Values for the required FIFO's to store data during the first level trigger latency are given

  15. Front end readout electronics for the CMS hadron calorimeter

    CERN Document Server

    Shaw, Terri M

    2002-01-01

    The front-end electronics for the CMS Hadron Calorimeter provides digitized data at the beam interaction rate of 40 MHz. Analog signals provided by hybrid photodiodes (HPDs) or photomultiplier tubes (PMTs) are digitized and the data is sent off board through serialized fiber optic links running at 1600 Mbps. In order to maximize the input signal, the front-end electronics are housed on the detector in close proximity to the scintillating fibers or phototubes. To fit the electronics into available space, custom crates, backplanes and cooling methods have had to be developed. During the expected ten-year lifetime, the front-end readout electronics will exist in an environment where radiation levels approach 330 rads and the neutron fluence will be 1.3E11 n/cm sup 2. For this reason, the design approach relies heavily upon custom radiation tolerant ASICs. This paper will present the system architecture of the front-end readout crates and describe their results with early prototypes.

  16. Front end readout electronics for the CMS hadron calorimeter

    International Nuclear Information System (INIS)

    Terri M. Shaw et al.

    2002-01-01

    The front-end electronics for the CMS Hadron Calorimeter provides digitized data at the beam interaction rate of 40 MHz. Analog signals provided by hybrid photodiodes (HPDs) or photomultiplier tubes (PMTs) are digitized and the data is sent off board through serialized fiber optic links running at 1600 Mbps. In order to maximize the input signal, the front-end electronics are housed on the detector in close proximity to the scintillating fibers or phototubes. To fit the electronics into available space, custom crates, backplanes and cooling methods have had to be developed. During the expected ten-year lifetime, the front-end readout electronics will exist in an environment where radiation levels approach 330 rads and the neutron fluence will be 1.3E11 n/cm 2 . For this reason, the design approach relies heavily upon custom radiation tolerant ASICs. This paper will present the system architecture of the front-end readout crates and describe their results with early prototypes

  17. The front-end data conversion and readout electronics for the CMS ECAL upgrade

    CERN Document Server

    Mazza, Gianni

    2017-01-01

    The High Luminosity LHC (HL-LHC) will require a significant upgrade of the readout electronics for the CMS Electromagnetic Calorimeter (ECAL). The Very Front-End (VFE) output signal will be sampled at 160 MS/s (i.e. four times the current sampling rate) with 13 bit resolution. Therefore, a high-speed, high-resolution ADC is required. Moreover, each readout channel will produce 2.08 Gb/s, thus requiring fast data transmission circuitry. A new readout architecture, based on two 12 bit, 160 MS/s ADCs, lossless data compression algorithms and fast serial links have been developed for the ECAL upgrade. These functions will be integrated in a single ASIC which is currently under design in a commercial CMOS 65 nm technology using radiation damage mitigation techniques.

  18. Characterization of the CBC2 readout ASIC for the CMS strip-tracker high-luminosity upgrade

    International Nuclear Information System (INIS)

    Braga, D; Hall, G; Pesaresi, M; Raymond, M; Jones, L; Murray, P; Prydderch, M

    2014-01-01

    The CMS Binary Chip 2 (CBC2) is a full-scale prototype ASIC developed for the front-end readout of the high-luminosity upgrade of the CMS silicon strip tracker. The 254-channel, 130 nm CMOS ASIC is designed for the binary readout of double-layer modules, and features cluster-width discrimination and coincidence logic for detecting high-P T track candidates. The chip was delivered in January 2013 and has since been bump-bonded to a dual-chip hybrid and extensively tested. The CBC2 is fully functional and working to specification: we present the result of electrical characterization of the chip, including gain, noise, threshold scan and power consumption, together with the performance of the stub finding logic. Finally we will outline the plan for future developments towards the production version

  19. The front-end data conversion and readout electronics for the CMS ECAL upgrade

    Science.gov (United States)

    Mazza, G.; Cometti, S.

    2018-03-01

    The High Luminosity LHC (HL-LHC) will require a significant upgrade of the readout electronics for the CMS Electromagnetic Calorimeter (ECAL). The Very Front-End (VFE) output signal will be sampled at 160 MS/s (i.e. four times the current sampling rate) with a 13 bits resolution. Therefore, a high-speed, high-resolution ADC is required. Moreover, each readout channel will produce 2.08 Gb/s, thus requiring a fast data transmission circuitry. A new readout architecture, based on two 12 bit, 160 MS/s ADCs, lossless data compression algorithms and fast serial links have been developed for the ECAL upgrade. These functions will be integrated in a single ASIC which is currently under design in a commercial CMOS 65 nm technology using radiation damage mitigation techniques.

  20. A VME-based readout system for the CMS Preshower sub-detector

    CERN Document Server

    Antchev, G; Bialas, W; Da Silva, J C; Kokkas, P; Manthos, N; Reynaud, S; Sidiropoulos, G; Snoeys, W; Vichoudis, P

    2007-01-01

    The CMS preshower is a fine grain detector that comprises 4288 silicon sensors, each containing 32 strips. The raw data are transferred from the detector to the counting room via 1208 optical fibres. Each fibre carries a 600-byte data packet per event. The maximum average level-1 trigger rate of 100 kHz results in a total data flow of ~72 GB/s from the preshower. For the readout of the preshower, 56 links to the CMS DAQ have been reserved, each having a bandwidth of 200 MB/s (2 kB/event). The total available downstream bandwidth of GB/s necessitates a reduction in the data volume by a factor of at least 7. A modular VME-based system is currently under development. The main objective of each VME board in this system is to acquire on-detector data from at least 22 optical links, perform on-line data reduction and pass the concentrated data to the CMS DAQ. The principle modules that the system is based on are being developed in collaboration with the TOTEM experiment.

  1. A software approach for readout and data acquisition in CMS

    CERN Document Server

    Antchev, G H; Chatellier, S; Cittolin, Sergio; Erhan, S; Gigi, D; Gutleber, J; Jacobs, C; Meijers, F; Nicolau, R; Orsini, L; Pollet, Lucien; Rácz, A; Samyn, D; Sinanis, N; Sphicas, Paris

    2000-01-01

    Traditional systems dominated by performance constraints tend to neglect other qualities such as maintainability and configurability. Object-Orientation allows one to encapsulate the technology differences in communication sub-systems and to provide a uniform view of data transport layer to the systems engineer. We applied this paradigm to the design and implementation of intelligent data servers in the Compact Muon Solenoid (CMS) data acquisition system at CERN to easily exploiting the physical communication resources of the available equipment. CMS is a high-energy physics experiment under study that incorporates a highly distributed data acquisition system. This paper outlines the architecture of one part, the so called Readout Unit, and shows how we can exploit the object advantage for systems with specific data rate requirements. A C++ streams communication layer with zero copying functionality has been established for UDP, TCP, DLPI and specific Myrinet and VME bus communication on the VxWorks real-time...

  2. LC HCAL Absorber And Active Media Comparisons Using a Particle-Flow Algorithm

    International Nuclear Information System (INIS)

    Magill, Steve; Kuhlmann, S.

    2006-01-01

    We compared Stainless Steel (SS) to Tungsten (W) as absorber for the HCAL in simulation using single particles (pions) and a Particle-Flow Algorithm applied to e + e - -> Z -> qqbar events. We then used the PFA to evaluate the performance characteristics of a LC HCAL using W absorber and comparing scintillator and RPC as active media. The W/Scintillator HCAL performs better than the SS/Scintillator version due to finer λ I sampling and narrower showers in the dense absorber. The W/Scintillator HCAL performs better than the W/RPC HCAL except in the number of unused hits in the PFA. Since this represents the confusion term in the PFA response, additional tuning and optimization of a W/RPC HCAL might significantly improve this HCAL configuration

  3. Readout architecture for the Pixel-Strip module of the CMS Outer Tracker Phase-2 upgrade

    CERN Document Server

    Caratelli, Alessandro; Jan Kaplon; Kloukinas, Konstantinos; Simone Scarfi

    2017-01-01

    The Outer Tracker upgrade of the Compact Muon Solenoid (CMS) experiment at CERN introduces new challenges for the front-end readout electronics. In particular, the capability of identifying particles with high transverse momentum using modules with double sensor layers requires high speed real time interconnects between readout ASICs. The Pixel-Strip module combines a pixelated silicon layer with a silicon-strip layer. Consequently, it needs two different readout ASICs, namely the Short Strip ASIC (SSA) for the strip sensor and the Macro Pixel ASIC (MPA) for the pixelated sensor. The architecture proposed in this paper allows for a total data flow between readout ASICs of $\\sim$100\\,Gbps and reduces the output data flow from 1.3\\,Tbps to 30\\,Gbps per module while limiting the total power density to below 100\\,mW/cm$^2$. In addition a system-level simulation framework of all the front-end readout ASICs is developed in order to verify the data processing algorithm and the hardware implementation allowing mult...

  4. An overview of CMS central hadron calorimeter

    CERN Document Server

    Katta, S

    2002-01-01

    The central hadron calorimeter for CMS detector is a sampling calorimeter with active medium as scintillator plates interleaved with brass absorber plates. It covers the central pseudorapidity region (¿ eta ¿<3.0). The design and construction aspects are reported. The status of construction and assembly of various subdetectors of HCAL are presented. (5 refs).

  5. The digital readout system for the CMS electromagnetic calorimeter

    International Nuclear Information System (INIS)

    Lofstedt, Bo

    2000-01-01

    The CMS Electromagnetic Calorimeter is a high-precision detector demanding innovative solutions in order to cope with the high dynamic range and the extreme high resolution of the detector as well as with the harsh environment created by the high level of radiation and the 4 T magnetic field. The readout system is partly placed within the detector and partly in the adjacent counting room. As the on-detector electronics must cope with the harsh environment the use of standard components is excluded for this part of the system. This paper describes the solutions adopted for the high-precision analogue stages, the A-D conversion, the optical transfer of the raw data from the on-detector part to the so-called Upper Level Readout, placed in the counting room, and the functionality of the latter. The ECAL is instrumental in providing information to the first-level trigger process and the generation of this information will be described. Also, the problem of reducing the raw data volume (6x10 12 bytes/s) to a level that can be handled by the central DAQ system (10 5 bytes/s) without degrading the physics performance will be discussed

  6. “Exploring High Energy Interactions with CMS at the LHC”

    Energy Technology Data Exchange (ETDEWEB)

    Sulak, Lawrence R. [; Boston Univ., MA (United States)

    2016-08-01

    This High Energy Physics research project achieved its goal of exploring high-energy interactions with 7, 8 and 13 TeV data accumulated by CMS at the Energy Frontier. For the original hadron calorimeter (HCAL) and for its upgrade during Long Shutdown 1 (LS1), the PI helped propose and implement the upgrading the phototubes, new electronics, and fast timing of the hadronic forward (HF) and hadronic outer (HO) calorimeters of CMS, projects which he had forcefully advocated since the inception of CMS. The PI and his colleagues Prof. J. Rohlf and chief electronics engineer E. Hazen, his post-docs A. Heister and S. Girgis, and his graduate students (P. Lawson and D. Arcaro) contributed software tools used in perfecting of μTCA and Advanced Mezzanine Card (AMC13) electronics, the PC board that provides clock, timing and DAQ service for HCAL (and now many other subdetectors and central systems in the upgraded CMS detector). This Task reaped the benefits of these hardware contributions 1) to hermiticity for missing energy searches, and 2) to forward tagging jets for Vector Boson Fusion processes by analyzing and publishing early data, including that for the Higgs discovery and for exotic and supersymmetric searches.

  7. Commissioning of CMS Forward Hadron Calorimeters with Upgraded Multi-anode PMTs and uTCA Readout

    CERN Document Server

    Tiras, Emrah; Onel, Yasar

    2016-01-01

    The high flux of charged particles interacting with the CMS Forward Hadron Calorimeter PMT windows introduced a significant background for the trigger and offline data analysis. During Long Shutdown 1, all of the original PMTs were replaced with multi-anode, thin window photomultiplier tubes. At the same time, the back-end electronic readout system was upgraded to uTCA readout. The experience with commissioning and calibration of the Forward Hadron Calorimeter is described as well as the uTCA system. The upgrade was successful and provided quality data for Run 2 data-analysis at 13 TeV.

  8. Test of the CMS microstrip silicon tracker readout and control system

    CERN Document Server

    Zghiche, A

    2001-01-01

    The Microstrip Silicon tracker of the CMS detector is designed to provide robust particle tracking and vertex reconstruction within a strong magnetic field in the high luminosity environment of the LHC. The Tracker readout system employs Front-End Driver cards to digitize and buffer the analogue data arriving via optical links from on detector pipeline chips. The control chain of the front-end electronic is built to operate via optical fibers in order to shield the communications from the outside noise. Components close to the final design have been assembled to be tested in the X5 beam area at CERN where a dedicated 25 ns temporal structure beam has been made available by the SPS. This paper describes the hardware and the software developed for readout and control of data acquired by the front-end electronics operating at 40 MHz, Some preliminary results of the tests performed in the 25 ns beam are also given. (8 refs).

  9. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Mans and P. De Barbaro

    2012-01-01

      During the year-end technical stop, HCAL has successfully undertaken a number of efforts in the detector and calibration areas. The full online software suite has been modernised to the next generation of Scientific Linux and 64-bit computing. In HF, a full set of 24 thin-window phototubes from the production set has been installed to allow further study of background rates as well as to evaluate the behaviour of the tubes under irradiation. The optical data fibres from two wedges of HB and an equivalent portion of HE and HF have been split, allowing the parallel operation of upgrade backend electronics without affecting the ongoing operations of the VME electronics. The HCAL DPG group has prepared the software and calibration for the restart at 8 TeV. The reconstruction and noise rejection have been tuned for higher pile-up conditions, while the final calibrations for HF will be used for a final re-reconstruction of the 2011 data as well as for the 2012 start-up. The DPG group is prepared for ...

  10. Functional tests of 2S modules for the CMS Phase-2 Tracker Upgrade with a MicroTCA-based readout system

    CERN Document Server

    Preuten, Marius; Klein, Katja; Lipinski, Martin; Rauch, Max; Feld, Lutz

    2017-01-01

    First full size 2S module prototypes for the CMS Phase-2 Outer Tracker Upgrade have been assembled. With two sensors of realistic dimensions and 16 CBC2 readout ASICs on two front-end hybrids, the characteristics of these novel and complex objects can be studied.A MicroTCA based readout system was developed to test multiple front-end hybrids simultaneously. Therefore the concurrent information of the full module can be used for noise and signal studies.

  11. CBC3: a CMS microstrip readout ASIC with logic for track-trigger modules at HL-LHC

    CERN Document Server

    Prydderch, Mark Lyndon; Bell, Stephen Jean-marc; Key-Charriere, M; Jones, Lawrence; Auzinger, Georg; Borg, Johan; Hall, Geoffrey; Pesaresi, Mark Franco; Raymond, David Mark; Uchida, Kirika; Goldstein, Joel; Seif El Nasr, Sarah

    2018-01-01

    The CBC3 is the latest version of the CMS Binary Chip ASIC for readout of the outer radial region of the upgraded CMS Tracker at HL-LHC. This 254-channel, 130nm CMOS ASIC is designed to be bump-bonded to a substrate to which sensors will be wire-bonded. It will instrument double-layer 2S-modules, consisting of two overlaid silicon microstrip sensors with aligned microstrips. On-chip logic identifies first level trigger primitives from high transverse-momentum tracks by selecting correlated hits in the two sensors. Delivered in late 2016, the CBC3 has been under test for several months, including X-ray irradiations and SEU testing. Results and performance are reported.

  12. R&D; studies on the hadronic calorimeter and physics simulations on the Standard Model and minimal supersymmetric Standard Model Higgs bosons in the CMS experiment

    CERN Document Server

    Duru, Firdevs

    2007-01-01

    This thesis consists of two main parts: R&D; studies done on the Compact Muon Solenoid (CMS) Hadronic Calorimeter (HCAL) and physics simulations on the Higgs boson for a Minimal Supersymmetric Standard Model (MSSM) and a Standard Model (SM) channel. In the first part, the air core light guides used in the read-out system of the Hadronic Forward (HF) calorimeter and the reflective materials used in them are studied. Then, tests and simulations were performed to find the most efficient way to collect Cerenkov light from the quartz plates, which are proposed as a substitute for the scintillator tiles in the Hadronic Endcap (HE) calorimeter due to radiation damage problems. In the second part physics simulations and their results are presented. The MSSM channel H/A[arrow right]ττ [arrow right]l l v v v v is studied to investigate the jet and missing transverse energy (MET) reconstruction of the CMS detector. The effects of the jet and MET corrections on the Higgs boson mass reconstruction are investigated. ...

  13. The CMS Beam Halo Monitor Electronics

    CERN Document Server

    AUTHOR|(CDS)2080684; Fabbri, F.; Grassi, T.; Hughes, E.; Mans, J.; Montanari, A.; Orfanelli, S.; Rusack, R.; Torromeo, G.; Stickland, D.P.; Stifter, K.

    2016-01-01

    The CMS Beam Halo Monitor has been successfully installed in the CMS cavern in LHC Long Shutdown 1 for measuring the machine induced background for LHC Run II. The system is based on 40 detector units composed of synthetic quartz Cherenkov radiators coupled to fast photomultiplier tubes. The readout electronics chain uses many components developed for the Phase 1 upgrade to the CMS Hadronic Calorimeter electronics, with dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal is digitized by a charge integrating ASIC (QIE10), providing both the signal rise time, with few ns resolution, and the charge integrated over one bunch crossing. The backend electronics uses microTCA technology and receives data via a high-speed 5 Gbps asynchronous link. It records histograms with sub-bunch crossing timing resolution and is readout by IPbus using the newly designed CMS data acquisition for non-event based data. The data is processed in real time and published to CMS and the LHC, providi...

  14. Development of a test system for the analysis of the read-out electronic cabling for the CMS drift tube chambers

    International Nuclear Information System (INIS)

    Fernandez Bedoya, C.; Montero, M.; Willmott, C.

    2004-01-01

    A test system has been developed for the analysis of the read-out electronics cabling for the CMS drift tube chambers. The read-out electronics will be placed inside some aluminium boxes, so-called Minicrates, which are going to be produced soon at CIEMAT. Due to the difficulty of detecting and repairing errors in the cables once they have been installed and recalling also to the large number of Minicrates that are going to be produced, it was decided to design and develop a test system for testing the cabling before its installation. (Author)

  15. Radiation-hard optoelectronic data transfer for the CMS tracker

    International Nuclear Information System (INIS)

    Troska, J.K.

    1999-01-01

    An introduction to the physics prospects of future experiments at the CERN Large Hadron Collider (LHC) will be given, along with the rather stringent requirements placed on their detectors by the LHC environment. Emphasis will be placed upon the particle tracking detectors, and the particular problem of their readout systems. The novel analogue optical readout scheme chosen by the Compact Muon Solenoid (CMS) experiment at the LHC will provide the basis for the thesis. The reasons for preferring analogue optical data transmission in CMS will be given, leading to a description of a generic optical readout scheme and its components. The particular scheme chosen by CMS makes as wide as possible use of commercially available components. These will be given greatest importance, with descriptions of component operation and characteristics pertinent to successful readout of the CMS tracker within the constraints of the LHC environment. Of particular concern is the effect of the LHC's harsh radiation environment on the operational characteristics of the readout system and its components. Work on radiation effects in components of the CMS tracker optical readout system will be described. This work includes the effects of ionising (gamma photon) and particle (neutron, proton, pion) irradiation on the operational characteristics and reliability of laser diodes, photodiodes, and optical fibres. System integration issues are discussed in the context of the long-term operation of the full CMS tracker readout system under laboratory conditions. It will be shown that system stability can be maintained even under widely varying ambient conditions. (author)

  16. CBC2: A CMS microstrip readout ASIC with logic for track-trigger modules at HL-LHC

    Energy Technology Data Exchange (ETDEWEB)

    Hall, G., E-mail: g.hall@imperial.ac.uk [Blackett Laboratory, Imperial College, London SW7 2AZ (United Kingdom); Pesaresi, M.; Raymond, M. [Blackett Laboratory, Imperial College, London SW7 2AZ (United Kingdom); Braga, D.; Jones, L.; Murray, P.; Prydderch, M. [Rutherford Appleton Laboratory, Chilton, Didcot, Oxon OX11 OQX (United Kingdom); Abbaneo, D.; Blanchot, G.; Honma, A.; Kovacs, M.; Vasey, F. [CERN, CH-1211, Geneva (Switzerland)

    2014-11-21

    The CBC2 is the latest version of the CMS Binary Chip ASIC for readout of the upgraded CMS Tracker at the High Luminosity LHC. It is designed in 130 nm CMOS with 254 input channels and will be bump-bonded to a substrate to which sensors will be wire-bonded. The CBC2 is designed to instrument double layer modules, consisting of two overlaid silicon microstrip sensors with aligned microstrips, in the outer tracker. It incorporates logic to identify L1 trigger primitives in the form of “stubs”: high transverse-momentum track candidates which are identified within the low momentum background by selecting correlated hits between two closely separated microstrip sensors. The first prototype modules have been assembled. The performance of the chip in recent laboratory tests is briefly reported and the status of module construction described.

  17. First Half Of CMS Hadron Calorimeter Completed

    CERN Multimedia

    2001-01-01

    CMS HCAL electronics coordinator John Elias from Fermilab inspecting the assembled first half of the calorimeter. The first half barrel of the CMS hadron calorimeter was completed last month and assembly work on the elements of the second half commenced just last week. This is not a simple task considering the fact that the constructed half-barrel consists of eighteen 30 tonne segments each made with 0.15 mm tolerance. But through the work of everyone on the CMS hadron calorimeter team it is all moving forward. In the LHC, detection of particles produced in collisions of two proton beams requires measurement of their energy. To do this, the particle energy has to be changed into a form that can be easily measured. This is achieved by stopping the initial particles in a dense medium, where they create a shower of secondary particles. While particles that interact through electromagnetic forces (electrons and positrons) create relatively small showers, the size of showers created by hadrons, particles that i...

  18. Performance of the CMS Beam Halo Monitor

    CERN Document Server

    CMS Collaboration

    2015-01-01

    The CMS Beam Halo Monitor has been successfully installed in the CMS cavern in LHC Long Shutdown 1 for measuring the machine induced background for LHC Run II. The system is based on 40 detector units composed of radiation hard synthetic quartz Cherenkov radiators coupled to fast photomultiplier tubes for a direction sensitive measurement. The readout electronics chain uses many components developed for the Phase 1 upgrade to the CMS Hadronic Calorimeter electronics, with dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal is digitized by a charge integrating ASIC (QIE10), providing both the signal rise time, with few ns resolution, and the charge integrated over one bunch crossing. The backend electronics uses microTCA technology and received data via a high-speed 5 Gbps asynchronous link. It records histograms with sub-bunch crossing timing resolution and is readout by IPbus using the newly designed CMS data acquisition for non-event based data. The data is processed i...

  19. Test beam results of the first CMS double-sided strip module prototypes using the CBC2 read-out chip

    Energy Technology Data Exchange (ETDEWEB)

    Harb, Ali, E-mail: ali.harb@desy.de; Mussgiller, Andreas; Hauk, Johannes

    2017-02-11

    The CMS Binary Chip (CBC) is a prototype version of the front-end read-out ASIC to be used in the silicon strip modules of the CMS outer tracking detector during the high luminosity phase of the LHC. The CBC is produced in 130 nm CMOS technology and bump-bonded to the hybrid of a double layer silicon strip module, the so-called 2S-p{sub T} module. It has 254 input channels and is designed to provide on-board trigger information to the first level trigger system of CMS, with the capability of cluster-width discrimination and high-p{sub T} track identification. In November 2013 the first 2S-p{sub T} module prototypes equipped with the CBC chips were put to test at the DESY-II test beam facility. Data were collected exploiting a beam of positrons with an energy ranging from 2 to 4 GeV. In this paper the test setup and the results are presented.

  20. Performance of the Prototype Readout System for the CMS Endcap Hadron Calorimeter Upgrade

    Science.gov (United States)

    Chaverin, Nate; Dittmann, Jay; Hatakeyama, Kenichi; Pastika, Nathaniel; CMS Collaboration

    2016-03-01

    The Compact Muon Solenoid (CMS) experiment at the CERN Large Hadron Collider (LHC) will upgrade the photodetectors and readout systems of the endcap hadron calorimeter during the technical stop scheduled for late 2016 and early 2017. A major milestone for this project was a highly successful testbeam run at CERN in August 2015. The testbeam run served as a full integration test of the electronics, allowing a study of the response of the preproduction electronics to the true detector light profile, as well as a test of the light yield of various new plastic scintillator materials. We present implications for the performance of the hadron calorimeter front-end electronics based on testbeam data, and we report on the production status of various components of the system in preparation for the upgrade.

  1. Deployment of the CMS Tracker AMC as Backend for the CMS Pixel Detector

    CERN Document Server

    AUTHOR|(CDS)2079000

    2016-01-01

    The silicon pixel detector of the CMS experiment at CERN will be replaced with an upgraded version at the beginning of 2017 with the new detector featuring an additional barrel- and end-cap layer resulting in an increased number of fully digital read-out links running at 400Mb/s. New versions of the PSI46 Read-Out Chip and Token Bit Manager have been developed to operate at higher rates and reduce data loss. Front-End Controller and Front-End Driver boards, based on the {\\textmu}TCA compatible CMS Tracker AMC, a variant of the FC7 card, are being developed using different mezzanines to host the optical links for the digital read-out and control system. An overview of the system architecture is presented, with details on the implementation, and first results obtained from test systems.

  2. High precision electromagnetic calorimetry with 40 MHz readout: the CMS crystal ECAL for the High-Luminosity LHC

    CERN Document Server

    Orimoto, Toyoko Jennifer

    2017-01-01

    The electromagnetic calorimeter (ECAL) of the Compact Muon Solenoid Experiment (CMS) will be upgraded to meet the challenging running conditions expected after the High-Luminosity upgrade of the LHC (HL-LHC). Particular challenges at HL-LHC are the harsh radiation environment, the increasing data rates and the extreme level of pile-up events, with up to 200 simultaneous proton-proton collisions. The detector will have to sustain an instantaneous luminosity of above $5 \\times 10^{34} cm^2 s^{-1}$, maintaining a performance similar to the one of LHC Run I for an integrated luminosity of 3 to 5 $ab^{-1}$. This poses stringent requirements on the radiation resistance of detector components, the readout and data transfer from the front end to the back end electronics, as well as the latency of the trigger system. The barrel region of the CMS ECAL will be able to retain the current lead tungstate crystals and avalanche photodiode detectors which will meet the energy measurement performance requirements throughout t...

  3. The supermodule insertion tool of the CMS electromagnetic calorimeter and the first trial insertion of a supermodule.

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    The first trial insertion of a complete Electromagnetic Calorimeter (ECAL) "supermodule" (1700 lead-tungstate crystals, with support structures, light detectors (avalanche photodiodes), readout electronics and cooling system) was performed on 1st March. This delicate operation - sliding a 2-tonne 3m-long object onto support rails (in real life these are attached to the barrel hadron calorimeter (HCAL)) - made use of a custom designed "squirrel cage". The rotatable squirrel cage allows the insertion of any supermodule into any of the 18 positions, including very fine (sub-mm) adjustments. The first supermodule will be inserted into the real HCAL later this month in preparation for the "magnet test and cosmic-ray challenge" (MTCC). In the first image the supermodule is in the centre and the alignment disks are highlighted by the flash.

  4. Energy reconstruction of hadrons in highly granular combined ECAL and HCAL systems

    Science.gov (United States)

    Israeli, Y.

    2018-05-01

    This paper discusses the hadronic energy reconstruction of two combined electromagnetic and hadronic calorimeter systems using physics prototypes of the CALICE collaboration: the silicon-tungsten electromagnetic calorimeter (Si-W ECAL) and the scintillator-SiPM based analog hadron calorimeter (AHCAL); and the scintillator-tungsten electromagnetic calorimeter (ScECAL) and the AHCAL. These systems were operated in hadron beams at CERN and FNAL, permitting the study of the performance in combined ECAL and HCAL systems. Two techniques for the energy reconstruction are used, a standard reconstruction based on calibrated sub-detector energy sums, and one based on a software compensation algorithm making use of the local energy density information provided by the high granularity of the detectors. The software compensation-based algorithm improves the hadronic energy resolution by up to 30% compared to the standard reconstruction. The combined system data show comparable energy resolutions to the one achieved for data with showers starting only in the AHCAL and therefore demonstrate the success of the inter-calibration of the different sub-systems, despite of their different geometries and different readout technologies.

  5. Performance of the CMS Hadron Calorimeter with Cosmic Ray Muons and LHC Beam Data

    CERN Document Server

    Chatrchyan, S; Sirunyan, A M; Adam, W; Arnold, B; Bergauer, H; Bergauer, T; Dragicevic, M; Eichberger, M; Erö, J; Friedl, M; Frühwirth, R; Ghete, V M; Hammer, J; Hänsel, S; Hoch, M; Hörmann, N; Hrubec, J; Jeitler, M; Kasieczka, G; Kastner, K; Krammer, M; Liko, D; Magrans de Abril, I; Mikulec, I; Mittermayr, F; Neuherz, B; Oberegger, M; Padrta, M; Pernicka, M; Rohringer, H; Schmid, S; Schöfbeck, R; Schreiner, T; Stark, R; Steininger, H; Strauss, J; Taurok, A; Teischinger, F; Themel, T; Uhl, D; Wagner, P; Waltenberger, W; Walzel, G; Widl, E; Wulz, C E; Chekhovsky, V; Dvornikov, O; Emeliantchik, I; Litomin, A; Makarenko, V; Marfin, I; Mossolov, V; Shumeiko, N; Solin, A; Stefanovitch, R; Suarez Gonzalez, J; Tikhonov, A; Fedorov, A; Karneyeu, A; Korzhik, M; Panov, V; Zuyeuski, R; Kuchinsky, P; Beaumont, W; Benucci, L; Cardaci, M; De Wolf, E A; Delmeire, E; Druzhkin, D; Hashemi, M; Janssen, X; Maes, T; Mucibello, L; Ochesanu, S; Rougny, R; Selvaggi, M; Van Haevermaet, H; Van Mechelen, P; Van Remortel, N; Adler, V; Beauceron, S; Blyweert, S; D'Hondt, J; De Weirdt, S; Devroede, O; Heyninck, J; Kalogeropoulos, A; Maes, J; Maes, M; Mozer, M U; Tavernier, S; Van Doninck, W; Van Mulders, P; Villella, I; Bouhali, O; Chabert, E C; Charaf, O; Clerbaux, B; De Lentdecker, G; Dero, V; Elgammal, S; Gay, A P R; Hammad, G H; Marage, P E; Rugovac, S; Vander Velde, C; Vanlaer, P; Wickens, J; Grunewald, M; Klein, B; Marinov, A; Ryckbosch, D; Thyssen, F; Tytgat, M; Vanelderen, L; Verwilligen, P; Basegmez, S; Bruno, G; Caudron, J; Delaere, C; Demin, P; Favart, D; Giammanco, A; Grégoire, G; Lemaitre, V; Militaru, O; Ovyn, S; Piotrzkowski, K; Quertenmont, L; Schul, N; Beliy, N; Daubie, E; Alves, G A; Pol, M E; Souza, M H G; Carvalho, W; De Jesus Damiao, D; De Oliveira Martins, C; Fonseca De Souza, S; Mundim, L; Oguri, V; Santoro, A; Silva Do Amaral, S M; Sznajder, A; Fernandez Perez Tomei, T R; Ferreira Dias, M A; Gregores, E M; Novaes, S F; Abadjiev, K; Anguelov, T; Damgov, J; Darmenov, N; Dimitrov, L; Genchev, V; Iaydjiev, P; Piperov, S; Stoykova, S; Sultanov, G; Trayanov, R; Vankov, I; Dimitrov, A; Dyulendarova, M; Kozhuharov, V; Litov, L; Marinova, E; Mateev, M; Pavlov, B; Petkov, P; Toteva, Z; Chen, G M; Chen, H S; Guan, W; Jiang, C H; Liang, D; Liu, B; Meng, X; Tao, J; Wang, J; Wang, Z; Xue, Z; Zhang, Z; Ban, Y; Cai, J; Ge, Y; Guo, S; Hu, Z; Mao, Y; Qian, S J; Teng, H; Zhu, B; Avila, C; Baquero Ruiz, M; Carrillo Montoya, C A; Gomez, A; Gomez Moreno, B; Ocampo Rios, A A; Osorio Oliveros, A F; Reyes Romero, D; Sanabria, J C; Godinovic, N; Lelas, K; Plestina, R; Polic, D; Puljak, I; Antunovic, Z; Dzelalija, M; Brigljevic, V; Duric, S; Kadija, K; Morovic, S; Fereos, R; Galanti, M; Mousa, J; Papadakis, A; Ptochos, F; Razis, P A; Tsiakkouri, D; Zinonos, Z; Hektor, A; Kadastik, M; Kannike, K; Müntel, M; Raidal, M; Rebane, L; Anttila, E; Czellar, S; Härkönen, J; Heikkinen, A; Karimäki, V; Kinnunen, R; Klem, J; Kortelainen, M J; Lampén, T; Lassila-Perini, K; Lehti, S; Lindén, T; Luukka, P; Mäenpää, T; Nysten, J; Tuominen, E; Tuominiemi, J; Ungaro, D; Wendland, L; Banzuzi, K; Korpela, A; Tuuva, T; Nedelec, P; Sillou, D; Besancon, M; Chipaux, R; Dejardin, M; Denegri, D; Descamps, J; Fabbro, B; Faure, J L; Ferri, F; Ganjour, S; Gentit, F X; Givernaud, A; Gras, P; Hamel de Monchenault, G; Jarry, P; Lemaire, M C; Locci, E; Malcles, J; Marionneau, M; Millischer, L; Rander, J; Rosowsky, A; Rousseau, D; Titov, M; Verrecchia, P; Baffioni, S; Bianchini, L; Bluj, M; Busson, P; Charlot, C; Dobrzynski, L; Granier de Cassagnac, R; Haguenauer, M; Miné, P; Paganini, P; Sirois, Y; Thiebaux, C; Zabi, A; Agram, J L; Besson, A; Bloch, D; Bodin, D; Brom, J M; Conte, E; Drouhin, F; Fontaine, J C; Gelé, D; Goerlach, U; Gross, L; Juillot, P; Le Bihan, A C; Patois, Y; Speck, J; Van Hove, P; Baty, C; Bedjidian, M; Blaha, J; Boudoul, G; Brun, H; Chanon, N; Chierici, R; Contardo, D; Depasse, P; Dupasquier, T; El Mamouni, H; Fassi, F; Fay, J; Gascon, S; Ille, B; Kurca, T; Le Grand, T; Lethuillier, M; Lumb, N; Mirabito, L; Perries, S; Vander Donckt, M; Verdier, P; Djaoshvili, N; Roinishvili, N; Roinishvili, V; Amaglobeli, N; Adolphi, R; Anagnostou, G; Brauer, R; Braunschweig, W; Edelhoff, M; Esser, H; Feld, L; Karpinski, W; Khomich, A; Klein, K; Mohr, N; Ostaptchouk, A; Pandoulas, D; Pierschel, G; Raupach, F; Schael, S; Schultz von Dratzig, A; Schwering, G; Sprenger, D; Thomas, M; Weber, M; Wittmer, B; Wlochal, M; Actis, O; Altenhöfer, G; Bender, W; Biallass, P; Erdmann, M; Fetchenhauer, G; Frangenheim, J; Hebbeker, T; Hilgers, G; Hinzmann, A; Hoepfner, K; Hof, C; Kirsch, M; Klimkovich, T; Kreuzer, P; Lanske, D; Merschmeyer, M; Meyer, A; Philipps, B; Pieta, H; Reithler, H; Schmitz, S A; Sonnenschein, L; Sowa, M; Steggemann, J; Szczesny, H; Teyssier, D; Zeidler, C; Bontenackels, M; Davids, M; Duda, M; Flügge, G; Geenen, H; Giffels, M; Haj Ahmad, W; Hermanns, T; Heydhausen, D; Kalinin, S; Kress, T; Linn, A; Nowack, A; Perchalla, L; Poettgens, M; Pooth, O; Sauerland, P; Stahl, A; Tornier, D; Zoeller, M H; Aldaya Martin, M; Behrens, U; Borras, K; Campbell, A; Castro, E; Dammann, D; Eckerlin, G; Flossdorf, A; Flucke, G; Geiser, A; Hatton, D; Hauk, J; Jung, H; Kasemann, M; Katkov, I; Kleinwort, C; Kluge, H; Knutsson, A; Kuznetsova, E; Lange, W; Lohmann, W; Mankel, R; Marienfeld, M; Meyer, A B; Miglioranzi, S; Mnich, J; Ohlerich, M; Olzem, J; Parenti, A; Rosemann, C; Schmidt, R; Schoerner-Sadenius, T; Volyanskyy, D; Wissing, C; Zeuner, W D; Autermann, C; Bechtel, F; Draeger, J; Eckstein, D; Gebbert, U; Kaschube, K; Kaussen, G; Klanner, R; Mura, B; Naumann-Emme, S; Nowak, F; Pein, U; Sander, C; Schleper, P; Schum, T; Stadie, H; Steinbrück, G; Thomsen, J; Wolf, R; Bauer, J; Blüm, P; Buege, V; Cakir, A; Chwalek, T; De Boer, W; Dierlamm, A; Dirkes, G; Feindt, M; Felzmann, U; Frey, M; Furgeri, A; Gruschke, J; Hackstein, C; Hartmann, F; Heier, S; Heinrich, M; Held, H; Hirschbuehl, D; Hoffmann, K H; Honc, S; Jung, C; Kuhr, T; Liamsuwan, T; Martschei, D; Mueller, S; Müller, Th; Neuland, M B; Niegel, M; Oberst, O; Oehler, A; Ott, J; Peiffer, T; Piparo, D; Quast, G; Rabbertz, K; Ratnikov, F; Ratnikova, N; Renz, M; Saout, C; Sartisohn, G; Scheurer, A; Schieferdecker, P; Schilling, F P; Schott, G; Simonis, H J; Stober, F M; Sturm, P; Troendle, D; Trunov, A; Wagner, W; Wagner-Kuhr, J; Zeise, M; Zhukov, V; Ziebarth, E B; Daskalakis, G; Geralis, T; Karafasoulis, K; Kyriakis, A; Loukas, D; Markou, A; Markou, C; Mavrommatis, C; Petrakou, E; Zachariadou, A; Gouskos, L; Katsas, P; Panagiotou, A; Evangelou, I; Kokkas, P; Manthos, N; Papadopoulos, I; Patras, V; Triantis, F A; Bencze, G; Boldizsar, L; Debreczeni, G; Hajdu, C; Hernath, S; Hidas, P; Horvath, D; Krajczar, K; Laszlo, A; Patay, G; Sikler, F; Toth, N; Vesztergombi, G; Beni, N; Christian, G; Imrek, J; Molnar, J; Novak, D; Palinkas, J; Szekely, G; Szillasi, Z; Tokesi, K; Veszpremi, V; Kapusi, A; Marian, G; Raics, P; Szabo, Z; Trocsanyi, Z L; Ujvari, B; Zilizi, G; Bansal, S; Bawa, H S; Beri, S B; Bhatnagar, V; Jindal, M; Kaur, M; Kaur, R; Kohli, J M; Mehta, M Z; Nishu, N; Saini, L K; Sharma, A; Singh, A; Singh, J B; Singh, S P; Ahuja, S; Arora, S; Bhattacharya, S; Chauhan, S; Choudhary, B C; Gupta, P; Jain, S; Jha, M; Kumar, A; Ranjan, K; Shivpuri, R K; Srivastava, A K; Choudhury, R K; Dutta, D; Kailas, S; Kataria, S K; Mohanty, A K; Pant, L M; Shukla, P; Topkar, A; Aziz, T; Guchait, M; Gurtu, A; Maity, M; Majumder, D; Majumder, G; Mazumdar, K; Nayak, A; Saha, A; Sudhakar, K; Banerjee, S; Dugad, S; Mondal, N K; Arfaei, H; Bakhshiansohi, H; Fahim, A; Jafari, A; Mohammadi Najafabadi, M; Moshaii, A; Paktinat Mehdiabadi, S; Rouhani, S; Safarzadeh, B; Zeinali, M; Felcini, M; Abbrescia, M; Barbone, L; Chiumarulo, F; Clemente, A; Colaleo, A; Creanza, D; Cuscela, G; De Filippis, N; De Palma, M; De Robertis, G; Donvito, G; Fedele, F; Fiore, L; Franco, M; Iaselli, G; Lacalamita, N; Loddo, F; Lusito, L; Maggi, G; Maggi, M; Manna, N; Marangelli, B; My, S; Natali, S; Nuzzo, S; Papagni, G; Piccolomo, S; Pierro, G A; Pinto, C; Pompili, A; Pugliese, G; Rajan, R; Ranieri, A; Romano, F; Roselli, G; Selvaggi, G; Shinde, Y; Silvestris, L; Tupputi, S; Zito, G; Abbiendi, G; Bacchi, W; Benvenuti, A C; Boldini, M; Bonacorsi, D; Braibant-Giacomelli, S; Cafaro, V D; Caiazza, S S; Capiluppi, P; Castro, A; Cavallo, F R; Codispoti, G; Cuffiani, M; D'Antone, I; Dallavalle, G M; Fabbri, F; Fanfani, A; Fasanella, D; Giacomelli, P; Giordano, V; Giunta, M; Grandi, C; Guerzoni, M; Marcellini, S; Masetti, G; Montanari, A; Navarria, F L; Odorici, F; Pellegrini, G; Perrotta, A; Rossi, A M; Rovelli, T; Siroli, G; Torromeo, G; Travaglini, R; Albergo, S; Costa, S; Potenza, R; Tricomi, A; Tuve, C; Barbagli, G; Broccolo, G; Ciulli, V; Civinini, C; D'Alessandro, R; Focardi, E; Frosali, S; Gallo, E; Genta, C; Landi, G; Lenzi, P; Meschini, M; Paoletti, S; Sguazzoni, G; Tropiano, A; Benussi, L; Bertani, M; Bianco, S; Colafranceschi, S; Colonna, D; Fabbri, F; Giardoni, M; Passamonti, L; Piccolo, D; Pierluigi, D; Ponzio, B; Russo, A; Fabbricatore, P; Musenich, R; Benaglia, A; Calloni, M; Cerati, G B; D'Angelo, P; De Guio, F; Farina, F M; Ghezzi, A; Govoni, P; Malberti, M; Malvezzi, S; Martelli, A; Menasce, D; Miccio, V; Moroni, L; Negri, P; Paganoni, M; Pedrini, D; Pullia, A; Ragazzi, S; Redaelli, N; Sala, S; Salerno, R; Tabarelli de Fatis, T; Tancini, V; Taroni, S; Buontempo, S; Cavallo, N; Cimmino, A; De Gruttola, M; Fabozzi, F; Iorio, A O M; Lista, L; Lomidze, D; Noli, P; Paolucci, P; Sciacca, C; Azzi, P; Bacchetta, N; Barcellan, L; Bellan, P; Bellato, M; Benettoni, M; Biasotto, M; Bisello, D; Borsato, E; Branca, A; Carlin, R; Castellani, L; Checchia, P; Conti, E; Dal Corso, F; De Mattia, M; Dorigo, T; Dosselli, U; Fanzago, F; Gasparini, F; Gasparini, U; Giubilato, P; Gonella, F; Gresele, A; Gulmini, M; Kaminskiy, A; Lacaprara, S; Lazzizzera, I; Margoni, M; Maron, G; Mattiazzo, S; Mazzucato, M; Meneghelli, M; Meneguzzo, A T; Michelotto, M; Montecassiano, F; Nespolo, M; Passaseo, M; Pegoraro, M; Perrozzi, L; Pozzobon, N; Ronchese, P; Simonetto, F; Toniolo, N; Torassa, E; Tosi, M; Triossi, A; Vanini, S; Ventura, S; Zotto, P; Zumerle, G; Baesso, P; Berzano, U; Bricola, S; Necchi, M M; Pagano, D; Ratti, S P; Riccardi, C; Torre, P; Vicini, A; Vitulo, P; Viviani, C; Aisa, D; Aisa, S; Babucci, E; Biasini, M; Bilei, G M; Caponeri, B; Checcucci, B; Dinu, N; Fanò, L; Farnesini, L; Lariccia, P; Lucaroni, A; Mantovani, G; Nappi, A; Piluso, A; Postolache, V; Santocchia, A; Servoli, L; Tonoiu, D; Vedaee, A; Volpe, R; Azzurri, P; Bagliesi, G; Bernardini, J; Berretta, L; Boccali, T; Bocci, A; Borrello, L; Bosi, F; Calzolari, F; Castaldi, R; Dell'Orso, R; Fiori, F; Foà, L; Gennai, S; Giassi, A; Kraan, A; Ligabue, F; Lomtadze, T; Mariani, F; Martini, L; Massa, M; Messineo, A; Moggi, A; Palla, F; Palmonari, F; Petragnani, G; Petrucciani, G; Raffaelli, F; Sarkar, S; Segneri, G; Serban, A T; Spagnolo, P; Tenchini, R; Tolaini, S; Tonelli, G; Venturi, A; Verdini, P G; Baccaro, S; Barone, L; Bartoloni, A; Cavallari, F; Dafinei, I; Del Re, D; Di Marco, E; Diemoz, M; Franci, D; Longo, E; Organtini, G; Palma, A; Pandolfi, F; Paramatti, R; Pellegrino, F; Rahatlou, S; Rovelli, C; Alampi, G; Amapane, N; Arcidiacono, R; Argiro, S; Arneodo, M; Biino, C; Borgia, M A; Botta, C; Cartiglia, N; Castello, R; Cerminara, G; Costa, M; Dattola, D; Dellacasa, G; Demaria, N; Dughera, G; Dumitrache, F; Graziano, A; Mariotti, C; Marone, M; Maselli, S; Migliore, E; Mila, G; Monaco, V; Musich, M; Nervo, M; Obertino, M M; Oggero, S; Panero, R; Pastrone, N; Pelliccioni, M; Romero, A; Ruspa, M; Sacchi, R; Solano, A; Staiano, A; Trapani, P P; Trocino, D; Vilela Pereira, A; Visca, L; Zampieri, A; Ambroglini, F; Belforte, S; Cossutti, F; Della Ricca, G; Gobbo, B; Penzo, A; Chang, S; Chung, J; Kim, D H; Kim, G N; Kong, D J; Park, H; Son, D C; Bahk, S Y; Song, S; Jung, S Y; Hong, B; Kim, H; Kim, J H; Lee, K S; Moon, D H; Park, S K; Rhee, H B; Sim, K S; Kim, J; Choi, M; Hahn, G; Park, I C; Choi, S; Choi, Y; Goh, J; Jeong, H; Kim, T J; Lee, J; Lee, S; Janulis, M; Martisiute, D; Petrov, P; Sabonis, T; Castilla Valdez, H; Sánchez Hernández, A; Carrillo Moreno, S; Morelos Pineda, A; Allfrey, P; Gray, R N C; Krofcheck, D; Bernardino Rodrigues, N; Butler, P H; Signal, T; Williams, J C; Ahmad, M; Ahmed, I; Ahmed, W; Asghar, M I; Awan, M I M; Hoorani, H R; Hussain, I; Khan, W A; Khurshid, T; Muhammad, S; Qazi, S; Shahzad, H; Cwiok, M; Dabrowski, R; Dominik, W; Doroba, K; Konecki, M; Krolikowski, J; Pozniak, K; Romaniuk, Ryszard; Zabolotny, W; Zych, P; Frueboes, T; Gokieli, R; Goscilo, L; Górski, M; Kazana, M; Nawrocki, K; Szleper, M; Wrochna, G; Zalewski, P; Almeida, N; Antunes Pedro, L; Bargassa, P; David, A; Faccioli, P; Ferreira Parracho, P G; Freitas Ferreira, M; Gallinaro, M; Guerra Jordao, M; Martins, P; Mini, G; Musella, P; Pela, J; Raposo, L; Ribeiro, P Q; Sampaio, S; Seixas, J; Silva, J; Silva, P; Soares, D; Sousa, M; Varela, J; Wöhri, H K; Altsybeev, I; Belotelov, I; Bunin, P; Ershov, Y; Filozova, I; Finger, M; Finger, M., Jr.; Golunov, A; Golutvin, I; Gorbounov, N; Kalagin, V; Kamenev, A; Karjavin, V; Konoplyanikov, V; Korenkov, V; Kozlov, G; Kurenkov, A; Lanev, A; Makankin, A; Mitsyn, V V; Moisenz, P; Nikonov, E; Oleynik, D; Palichik, V; Perelygin, V; Petrosyan, A; Semenov, R; Shmatov, S; Smirnov, V; Smolin, D; Tikhonenko, E; Vasil'ev, S; Vishnevskiy, A; Volodko, A; Zarubin, A; Zhiltsov, V; Bondar, N; Chtchipounov, L; Denisov, A; Gavrikov, Y; Gavrilov, G; Golovtsov, V; Ivanov, Y; Kim, V; Kozlov, V; Levchenko, P; Obrant, G; Orishchin, E; Petrunin, A; Shcheglov, Y; Shchetkovskiy, A; Sknar, V; Smirnov, I; Sulimov, V; Tarakanov, V; Uvarov, L; Vavilov, S; Velichko, G; Volkov, S; Vorobyev, A; Andreev, Yu; Anisimov, A; Antipov, P; Dermenev, A; Gninenko, S; Golubev, N; Kirsanov, M; Krasnikov, N; Matveev, V; Pashenkov, A; Postoev, V E; Solovey, A; Toropin, A; Troitsky, S; Baud, A; Epshteyn, V; Gavrilov, V; Ilina, N; Kaftanov, V; Kolosov, V; Kossov, M; Krokhotin, A; Kuleshov, S; Oulianov, A; Safronov, G; Semenov, S; Shreyber, I; Stolin, V; Vlasov, E; Zhokin, A; Boos, E; Dubinin, M; Dudko, L; Ershov, A; Gribushin, A; Klyukhin, V; Kodolova, O; Lokhtin, I; Petrushanko, S; Sarycheva, L; Savrin, V; Snigirev, A; Vardanyan, I; Dremin, I; Kirakosyan, M; Konovalova, N; Rusakov, S V; Vinogradov, A; Akimenko, S; Artamonov, A; Azhgirey, I; Bitioukov, S; Burtovoy, V; Grishin, V; Kachanov, V; Konstantinov, D; Krychkine, V; Levine, A; Lobov, I; Lukanin, V; Mel'nik, Y; Petrov, V; Ryutin, R; Slabospitsky, S; Sobol, A; Sytine, A; Tourtchanovitch, L; Troshin, S; Tyurin, N; Uzunian, A; Volkov, A; Adzic, P; Djordjevic, M; Jovanovic, D; Krpic, D; Maletic, D; Puzovic, J; Smiljkovic, N; Aguilar-Benitez, M; Alberdi, J; Alcaraz Maestre, J; Arce, P; Barcala, J M; Battilana, C; Burgos Lazaro, C; Caballero Bejar, J; Calvo, E; Cardenas Montes, M; Cepeda, M; Cerrada, M; Chamizo Llatas, M; Clemente, F; Colino, N; Daniel, M; De La Cruz, B; Delgado Peris, A; Diez Pardos, C; Fernandez Bedoya, C; Fernández Ramos, J P; Ferrando, A; Flix, J; Fouz, M C; Garcia-Abia, P; Garcia-Bonilla, A C; Gonzalez Lopez, O; Goy Lopez, S; Hernandez, J M; Josa, M I; Marin, J; Merino, G; Molina, J; Molinero, A; Navarrete, J J; Oller, J C; Puerta Pelayo, J; Romero, L; Santaolalla, J; Villanueva Munoz, C; Willmott, C; Yuste, C; Albajar, C; Blanco Otano, M; de Trocóniz, J F; Garcia Raboso, A; Lopez Berengueres, J O; Cuevas, J; Fernandez Menendez, J; Gonzalez Caballero, I; Lloret Iglesias, L; Naves Sordo, H; Vizan Garcia, J M; Cabrillo, I J; Calderon, A; Chuang, S H; Diaz Merino, I; Diez Gonzalez, C; Duarte Campderros, J; Fernandez, M; Gomez, G; Gonzalez Sanchez, J; Gonzalez Suarez, R; Jorda, C; Lobelle Pardo, P; Lopez Virto, A; Marco, J; Marco, R; Martinez Rivero, C; Martinez Ruiz del Arbol, P; Matorras, F; Rodrigo, T; Ruiz Jimeno, A; Scodellaro, L; Sobron Sanudo, M; Vila, I; Vilar Cortabitarte, R; Abbaneo, D; Albert, E; Alidra, M; Ashby, S; Auffray, E; Baechler, J; Baillon, P; Ball, A H; Bally, S L; Barney, D; Beaudette, F; Bellan, R; Benedetti, D; Benelli, G; Bernet, C; Bloch, P; Bolognesi, S; Bona, M; Bos, J; Bourgeois, N; Bourrel, T; Breuker, H; Bunkowski, K; Campi, D; Camporesi, T; Cano, E; Cattai, A; Chatelain, J P; Chauvey, M; Christiansen, T; Coarasa Perez, J A; Conde Garcia, A; Covarelli, R; Curé, B; De Roeck, A; Delachenal, V; Deyrail, D; Di Vincenzo, S; Dos Santos, S; Dupont, T; Edera, L M; Elliott-Peisert, A; Eppard, M; Favre, M; Frank, N; Funk, W; Gaddi, A; Gastal, M; Gateau, M; Gerwig, H; Gigi, D; Gill, K; Giordano, D; Girod, J P; Glege, F; Gomez-Reino Garrido, R; Goudard, R; Gowdy, S; Guida, R; Guiducci, L; Gutleber, J; Hansen, M; Hartl, C; Harvey, J; Hegner, B; Hoffmann, H F; Holzner, A; Honma, A; Huhtinen, M; Innocente, V; Janot, P; Le Godec, G; Lecoq, P; Leonidopoulos, C; Loos, R; Lourenço, C; Lyonnet, A; Macpherson, A; Magini, N; Maillefaud, J D; Maire, G; Mäki, T; Malgeri, L; Mannelli, M; Masetti, L; Meijers, F; Meridiani, P; Mersi, S; Meschi, E; Meynet Cordonnier, A; Moser, R; Mulders, M; Mulon, J; Noy, M; Oh, A; Olesen, G; Onnela, A; Orimoto, T; Orsini, L; Perez, E; Perinic, G; Pernot, J F; Petagna, P; Petiot, P; Petrilli, A; Pfeiffer, A; Pierini, M; Pimiä, M; Pintus, R; Pirollet, B; Postema, H; Racz, A; Ravat, S; Rew, S B; Rodrigues Antunes, J; Rolandi, G; Rovere, M; Ryjov, V; Sakulin, H; Samyn, D; Sauce, H; Schäfer, C; Schlatter, W D; Schröder, M; Schwick, C; Sciaba, A; Segoni, I; Sharma, A; Siegrist, N; Siegrist, P; Sinanis, N; Sobrier, T; Sphicas, P; Spiga, D; Spiropulu, M; Stöckli, F; Traczyk, P; Tropea, P; Troska, J; Tsirou, A; Veillet, L; Veres, G I; Voutilainen, M; Wertelaers, P; Zanetti, M; Bertl, W; Deiters, K; Erdmann, W; Gabathuler, K; Horisberger, R; Ingram, Q; Kaestli, H C; König, S; Kotlinski, D; Langenegger, U; Meier, F; Renker, D; Rohe, T; Sibille, J; Starodumov, A; Betev, B; Caminada, L; Chen, Z; Cittolin, S; Da Silva Di Calafiori, D R; Dambach, S; Dissertori, G; Dittmar, M; Eggel, C; Eugster, J; Faber, G; Freudenreich, K; Grab, C; Hervé, A; Hintz, W; Lecomte, P; Luckey, P D; Lustermann, W; Marchica, C; Milenovic, P; Moortgat, F; Nardulli, A; Nessi-Tedaldi, F; Pape, L; Pauss, F; Punz, T; Rizzi, A; Ronga, F J; Sala, L; Sanchez, A K; Sawley, M C; Sordini, V; Stieger, B; Tauscher, L; Thea, A; Theofilatos, K; Treille, D; Trüb, P; Weber, M; Wehrli, L; Weng, J; Zelepoukine, S; Amsler, C; Chiochia, V; De Visscher, S; Regenfus, C; Robmann, P; Rommerskirchen, T; Schmidt, A; Tsirigkas, D; Wilke, L; Chang, Y H; Chen, E A; Chen, W T; Go, A; Kuo, C M; Li, S W; Lin, W; Bartalini, P; Chang, P; Chao, Y; Chen, K F; Hou, W S; Hsiung, Y; Lei, Y J; Lin, S W; Lu, R S; Schümann, J; Shiu, J G; Tzeng, Y M; Ueno, K; Velikzhanin, Y; Wang, C C; Wang, M; Adiguzel, A; Ayhan, A; Azman Gokce, A; Bakirci, M N; Cerci, S; Dumanoglu, I; Eskut, E; Girgis, S; Gurpinar, E; Hos, I; Karaman, T; Kayis Topaksu, A; Kurt, P; Önengüt, G; Önengüt Gökbulut, G; Ozdemir, K; Ozturk, S; Polatöz, A; Sogut, K; Tali, B; Topakli, H; Uzun, D; Vergili, L N; Vergili, M; Akin, I V; Aliev, T; Bilmis, S; Deniz, M; Gamsizkan, H; Guler, A M; Öcalan, K; Serin, M; Sever, R; Surat, U E; Zeyrek, M; Deliomeroglu, M; Demir, D; Gülmez, E; Halu, A; Isildak, B; Kaya, M; Kaya, O; Ozkorucuklu, S; Sonmez, N; Levchuk, L; Lukyanenko, S; Soroka, D; Zub, S; Bostock, F; Brooke, J J; Cheng, T L; Cussans, D; Frazier, R; Goldstein, J; Grant, N; Hansen, M; Heath, G P; Heath, H F; Hill, C; Huckvale, B; Jackson, J; Mackay, C K; Metson, S; Newbold, D M; Nirunpong, K; Smith, V J; Velthuis, J; Walton, R; Bell, K W; Brew, C; Brown, R M; Camanzi, B; Cockerill, D J A; Coughlan, J A; Geddes, N I; Harder, K; Harper, S; Kennedy, B W; Murray, P; Shepherd-Themistocleous, C H; Tomalin, I R; Williams, J H; Womersley, W J; Worm, S D; Bainbridge, R; Ball, G; Ballin, J; Beuselinck, R; Buchmuller, O; Colling, D; Cripps, N; Davies, G; Della Negra, M; Foudas, C; Fulcher, J; Futyan, D; Hall, G; Hays, J; Iles, G; Karapostoli, G; MacEvoy, B C; Magnan, A M; Marrouche, J; Nash, J; Nikitenko, A; Papageorgiou, A; Pesaresi, M; Petridis, K; Pioppi, M; Raymond, D M; Rompotis, N; Rose, A; Ryan, M J; Seez, C; Sharp, P; Sidiropoulos, G; Stettler, M; Stoye, M; Takahashi, M; Tapper, A; Timlin, C; Tourneur, S; Vazquez Acosta, M; Virdee, T; Wakefield, S; Wardrope, D; Whyntie, T; Wingham, M; Cole, J E; Goitom, I; Hobson, P R; Khan, A; Kyberd, P; Leslie, D; Munro, C; Reid, I D; Siamitros, C; Taylor, R; Teodorescu, L; Yaselli, I; Bose, T; Carleton, M; Hazen, E; Heering, A H; Heister, A; John, J St; Lawson, P; Lazic, D; Osborne, D; Rohlf, J; Sulak, L; Wu, S; Andrea, J; Avetisyan, A; Bhattacharya, S; Chou, J P; Cutts, D; Esen, S; Kukartsev, G; Landsberg, G; Narain, M; Nguyen, D; Speer, T; Tsang, K V; Breedon, R; Calderon De La Barca Sanchez, M; Case, M; Cebra, D; Chertok, M; Conway, J; Cox, P T; Dolen, J; Erbacher, R; Friis, E; Ko, W; Kopecky, A; Lander, R; Lister, A; Liu, H; Maruyama, S; Miceli, T; Nikolic, M; Pellett, D; Robles, J; Searle, M; Smith, J; Squires, M; Stilley, J; Tripathi, M; Vasquez Sierra, R; Veelken, C; Andreev, V; Arisaka, K; Cline, D; Cousins, R; Erhan, S; Hauser, J; Ignatenko, M; Jarvis, C; Mumford, J; Plager, C; Rakness, G; Schlein, P; Tucker, J; Valuev, V; Wallny, R; Yang, X; Babb, J; Bose, M; Chandra, A; Clare, R; Ellison, J A; Gary, J W; Hanson, G; Jeng, G Y; Kao, S C; Liu, F; Liu, H; Luthra, A; Nguyen, H; Pasztor, G; Satpathy, A; Shen, B C; Stringer, R; Sturdy, J; Sytnik, V; Wilken, R; Wimpenny, S; Branson, J G; Dusinberre, E; Evans, D; Golf, F; Kelley, R; Lebourgeois, M; Letts, J; Lipeles, E; Mangano, B; Muelmenstaedt, J; Norman, M; Padhi, S; Petrucci, A; Pi, H; Pieri, M; Ranieri, R; Sani, M; Sharma, V; Simon, S; Würthwein, F; Yagil, A; Campagnari, C; D'Alfonso, M; Danielson, T; Garberson, J; Incandela, J; Justus, C; Kalavase, P; Koay, S A; Kovalskyi, D; Krutelyov, V; Lamb, J; Lowette, S; Pavlunin, V; Rebassoo, F; Ribnik, J; Richman, J; Rossin, R; Stuart, D; To, W; Vlimant, J R; Witherell, M; Apresyan, A; Bornheim, A; Bunn, J; Chiorboli, M; Gataullin, M; Kcira, D; Litvine, V; Ma, Y; Newman, H B; Rogan, C; Timciuc, V; Veverka, J; Wilkinson, R; Yang, Y; Zhang, L; Zhu, K; Zhu, R Y; Akgun, B; Carroll, R; Ferguson, T; Jang, D W; Jun, S Y; Paulini, M; Russ, J; Terentyev, N; Vogel, H; Vorobiev, I; Cumalat, J P; Dinardo, M E; Drell, B R; Ford, W T; Heyburn, B; Luiggi Lopez, E; Nauenberg, U; Stenson, K; Ulmer, K; Wagner, S R; Zang, S L; Agostino, L; Alexander, J; Blekman, F; Cassel, D; Chatterjee, A; Das, S; Gibbons, L K; Heltsley, B; Hopkins, W; Khukhunaishvili, A; Kreis, B; Kuznetsov, V; Patterson, J R; Puigh, D; Ryd, A; Shi, X; Stroiney, S; Sun, W; Teo, W D; Thom, J; Vaughan, J; Weng, Y; Wittich, P; Beetz, C P; Cirino, G; Sanzeni, C; Winn, D; Abdullin, S; Afaq, M A; Albrow, M; Ananthan, B; Apollinari, G; Atac, M; Badgett, W; Bagby, L; Bakken, J A; Baldin, B; Banerjee, S; Banicz, K; Bauerdick, L A T; Beretvas, A; Berryhill, J; Bhat, P C; Biery, K; Binkley, M; Bloch, I; Borcherding, F; Brett, A M; Burkett, K; Butler, J N; Chetluru, V; Cheung, H W K; Chlebana, F; Churin, I; Cihangir, S; Crawford, M; Dagenhart, W; Demarteau, M; Derylo, G; Dykstra, D; Eartly, D P; Elias, J E; Elvira, V D; Evans, D; Feng, L; Fischler, M; Fisk, I; Foulkes, S; Freeman, J; Gartung, P; Gottschalk, E; Grassi, T; Green, D; Guo, Y; Gutsche, O; Hahn, A; Hanlon, J; Harris, R M; Holzman, B; Howell, J; Hufnagel, D; James, E; Jensen, H; Johnson, M; Jones, C D; Joshi, U; Juska, E; Kaiser, J; Klima, B; Kossiakov, S; Kousouris, K; Kwan, S; Lei, C M; Limon, P; Lopez Perez, J A; Los, S; Lueking, L; Lukhanin, G; Lusin, S; Lykken, J; Maeshima, K; Marraffino, J M; Mason, D; McBride, P; Miao, T; Mishra, K; Moccia, S; Mommsen, R; Mrenna, S; Muhammad, A S; Newman-Holmes, C; Noeding, C; O'Dell, V; Prokofyev, O; Rivera, R; Rivetta, C H; Ronzhin, A; Rossman, P; Ryu, S; Sekhri, V; Sexton-Kennedy, E; Sfiligoi, I; Sharma, S; Shaw, T M; Shpakov, D; Skup, E; Smith, R P; Soha, A; Spalding, W J; Spiegel, L; Suzuki, I; Tan, P; Tanenbaum, W; Tkaczyk, S; Trentadue, R; Uplegger, L; Vaandering, E W; Vidal, R; Whitmore, J; Wicklund, E; Wu, W; Yarba, J; Yumiceva, F; Yun, J C; Acosta, D; Avery, P; Barashko, V; Bourilkov, D; Chen, M; Di Giovanni, G P; Dobur, D; Drozdetskiy, A; Field, R D; Fu, Y; Furic, I K; Gartner, J; Holmes, D; Kim, B; Klimenko, S; Konigsberg, J; Korytov, A; Kotov, K; Kropivnitskaya, A; Kypreos, T; Madorsky, A; Matchev, K; Mitselmakher, G; Pakhotin, Y; Piedra Gomez, J; Prescott, C; Rapsevicius, V; Remington, R; Schmitt, M; Scurlock, B; Wang, D; Yelton, J; Ceron, C; Gaultney, V; Kramer, L; Lebolo, L M; Linn, S; Markowitz, P; Martinez, G; Rodriguez, J L; Adams, T; Askew, A; Baer, H; Bertoldi, M; Chen, J; Dharmaratna, W G D; Gleyzer, S V; Haas, J; Hagopian, S; Hagopian, V; Jenkins, M; Johnson, K F; Prettner, E; Prosper, H; Sekmen, S; Baarmand, M M; Guragain, S; Hohlmann, M; Kalakhety, H; Mermerkaya, H; Ralich, R; Vodopiyanov, I; Abelev, B; Adams, M R; Anghel, I M; Apanasevich, L; Bazterra, V E; Betts, R R; Callner, J; Castro, M A; Cavanaugh, R; Dragoiu, C; Garcia-Solis, E J; Gerber, C E; Hofman, D J; Khalatian, S; Mironov, C; Shabalina, E; Smoron, A; Varelas, N; Akgun, U; Albayrak, E A; Ayan, A S; Bilki, B; Briggs, R; Cankocak, K; Chung, K; Clarida, W; Debbins, P; Duru, F; Ingram, F D; Lae, C K; McCliment, E; Merlo, J P; Mestvirishvili, A; Miller, M J; Moeller, A; Nachtman, J; Newsom, C R; Norbeck, E; Olson, J; Onel, Y; Ozok, F; Parsons, J; Schmidt, I; Sen, S; Wetzel, J; Yetkin, T; Yi, K; Barnett, B A; Blumenfeld, B; Bonato, A; Chien, C Y; Fehling, D; Giurgiu, G; Gritsan, A V; Guo, Z J; Maksimovic, P; Rappoccio, S; Swartz, M; Tran, N V; Zhang, Y; Baringer, P; Bean, A; Grachov, O; Murray, M; Radicci, V; Sanders, S; Wood, J S; Zhukova, V; Bandurin, D; Bolton, T; Kaadze, K; Liu, A; Maravin, Y; Onoprienko, D; Svintradze, I; Wan, Z; Gronberg, J; Hollar, J; Lange, D; Wright, D; Baden, D; Bard, R; Boutemeur, M; Eno, S C; Ferencek, D; Hadley, N J; Kellogg, R G; Kirn, M; Kunori, S; Rossato, K; Rumerio, P; Santanastasio, F; Skuja, A; Temple, J; Tonjes, M B; Tonwar, S C; Toole, T; Twedt, E; Alver, B; Bauer, G; Bendavid, J; Busza, W; Butz, E; Cali, I A; Chan, M; D'Enterria, D; Everaerts, P; Gomez Ceballos, G; Hahn, K A; Harris, P; Jaditz, S; Kim, Y; Klute, M; Lee, Y J; Li, W; Loizides, C; Ma, T; Miller, M; Nahn, S; Paus, C; Roland, C; Roland, G; Rudolph, M; Stephans, G; Sumorok, K; Sung, K; Vaurynovich, S; Wenger, E A; Wyslouch, B; Xie, S; Yilmaz, Y; Yoon, A S; Bailleux, D; Cooper, S I; Cushman, P; Dahmes, B; De Benedetti, A; Dolgopolov, A; Dudero, P R; Egeland, R; Franzoni, G; Haupt, J; Inyakin, A; Klapoetke, K; Kubota, Y; Mans, J; Mirman, N; Petyt, D; Rekovic, V; Rusack, R; Schroeder, M; Singovsky, A; Zhang, J; Cremaldi, L M; Godang, R; Kroeger, R; Perera, L; Rahmat, R; Sanders, D A; Sonnek, P; Summers, D; Bloom, K; Bockelman, B; Bose, S; Butt, J; Claes, D R; Dominguez, A; Eads, M; Keller, J; Kelly, T; Kravchenko, I; Lazo-Flores, J; Lundstedt, C; Malbouisson, H; Malik, S; Snow, G R; Baur, U; Iashvili, I; Kharchilava, A; Kumar, A; Smith, K; Strang, M; Alverson, G; Barberis, E; Boeriu, O; Eulisse, G; Govi, G; McCauley, T; Musienko, Y; Muzaffar, S; Osborne, I; Paul, T; Reucroft, S; Swain, J; Taylor, L; Tuura, L; Anastassov, A; Gobbi, B; Kubik, A; Ofierzynski, R A; Pozdnyakov, A; Schmitt, M; Stoynev, S; Velasco, M; Won, S; Antonelli, L; Berry, D; Hildreth, M; Jessop, C; Karmgard, D J; Kolberg, T; Lannon, K; Lynch, S; Marinelli, N; Morse, D M; Ruchti, R; Slaunwhite, J; Warchol, J; Wayne, M; Bylsma, B; Durkin, L S; Gilmore, J; Gu, J; Killewald, P; Ling, T Y; Williams, G; Adam, N; Berry, E; Elmer, P; Garmash, A; Gerbaudo, D; Halyo, V; Hunt, A; Jones, J; Laird, E; Marlow, D; Medvedeva, T; Mooney, M; Olsen, J; Piroué, P; Stickland, D; Tully, C; Werner, J S; Wildish, T; Xie, Z; Zuranski, A; Acosta, J G; Bonnett Del Alamo, M; Huang, X T; Lopez, A; Mendez, H; Oliveros, S; Ramirez Vargas, J E; Santacruz, N; Zatzerklyany, A; Alagoz, E; Antillon, E; Barnes, V E; Bolla, G; Bortoletto, D; Everett, A; Garfinkel, A F; Gecse, Z; Gutay, L; Ippolito, N; Jones, M; Koybasi, O; Laasanen, A T; Leonardo, N; Liu, C; Maroussov, V; Merkel, P; Miller, D H; Neumeister, N; Sedov, A; Shipsey, I; Yoo, H D; Zheng, Y; Jindal, P; Parashar, N; Cuplov, V; Ecklund, K M; Geurts, F J M; Liu, J H; Maronde, D; Matveev, M; Padley, B P; Redjimi, R; Roberts, J; Sabbatini, L; Tumanov, A; Betchart, B; Bodek, A; Budd, H; Chung, Y S; de Barbaro, P; Demina, R; Flacher, H; Gotra, Y; Harel, A; Korjenevski, S; Miner, D C; Orbaker, D; Petrillo, G; Vishnevskiy, D; Zielinski, M; Bhatti, A; Demortier, L; Goulianos, K; Hatakeyama, K; Lungu, G; Mesropian, C; Yan, M; Atramentov, O; Bartz, E; Gershtein, Y; Halkiadakis, E; Hits, D; Lath, A; Rose, K; Schnetzer, S; Somalwar, S; Stone, R; Thomas, S; Watts, T L; Cerizza, G; Hollingsworth, M; Spanier, S; Yang, Z C; York, A; Asaadi, J; Aurisano, A; Eusebi, R; Golyash, A; Gurrola, A; Kamon, T; Nguyen, C N; Pivarski, J; Safonov, A; Sengupta, S; Toback, D; Weinberger, M; Akchurin, N; Berntzon, L; Gumus, K; Jeong, C; Kim, H; Lee, S W; Popescu, S; Roh, Y; Sill, A; Volobouev, I; Washington, E; Wigmans, R; Yazgan, E; Engh, D; Florez, C; Johns, W; Pathak, S; Sheldon, P; Andelin, D; Arenton, M W; Balazs, M; Boutle, S; Buehler, M; Conetti, S; Cox, B; Hirosky, R; Ledovskoy, A; Neu, C; Phillips II, D; Ronquest, M; Yohay, R; Gollapinni, S; Gunthoti, K; Harr, R; Karchin, P E; Mattson, M; Sakharov, A; Anderson, M; Bachtis, M; Bellinger, J N; Carlsmith, D; Crotty, I; Dasu, S; Dutta, S; Efron, J; Feyzi, F; Flood, K; Gray, L; Grogg, K S; Grothe, M; Hall-Wilton, R; Jaworski, M; Klabbers, P; Klukas, J; Lanaro, A; Lazaridis, C; Leonard, J; Loveless, R; Magrans de Abril, M; Mohapatra, A; Ott, G; Polese, G; Reeder, D; Savin, A; Smith, W H; Sourkov, A; Swanson, J; Weinberg, M; Wenman, D; Wensveen, M; White, A

    2010-01-01

    The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters underground. Various measurements were also performed during the few days of beam in the LHC in September 2008. Calibration parameters were extracted, and the energy response of the HCAL determined from test beam data has been checked.

  6. Phase 1 upgrade of the CMS forward hadronic calorimeter

    CERN Document Server

    Noonan, Daniel Christopher

    2017-01-01

    The CMS experiment at the Large Hadron Collider at CERN is upgrading the photo- detection and readout system of the forward hadronic calorimeter. The phase 1 upgrade of the CMS forward calorimeter requires the replacement of the current photomultiplier tubes, as well as the installation of a new front-end readout system. The new photomultiplier tubes contain a thinner window as well as multi-anode readout. The front-end electronics will use the QIE10 ASIC which combines signal digitization with timing information. The major components of the upgrade as well as the current status are described in this paper.

  7. Parameters of the preproduction series SiPMs for the CMS HCAL phase I upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Heering, A., E-mail: Adriaan.Heering@cern.ch [University of Notre Dame, Notre Dame, IN 46556 (United States); Musienko, Yu., E-mail: Iouri.Musienko@cern.ch [University of Notre Dame, Notre Dame, IN 46556 (United States); Institute for Nuclear Research RAS, pr. 60-letiya Oktyabrya 7a, 117312 Moscow (Russian Federation); Ruchti, R.; Wayne, M. [University of Notre Dame, Notre Dame, IN 46556 (United States); Karneyeu, A.; Postoev, V. [Institute for Nuclear Research RAS, pr. 60-letiya Oktyabrya 7a, 117312 Moscow (Russian Federation)

    2016-07-11

    In 2012 the HCAL SiPM photo sensor upgrade was approved for the increased luminosity (5*10{sup 34}) of SLHC. The upgrade will replace the current hybrid photodiodes (HPDs) with multi-pixel Geiger-mode avalanche photodiodes, also known as silicon photomultipliers (SiPMs). A key aspect of the upgrade to SiPMs is to add longitudinal segmentation and improve signal to noise to compensate for scintillator radiation damage. After 5 years of R&D with multiple companies we developed custom large dynamic range SiPMs with large PDE and small ENC. To ensure good mechanical alignment and easy handling of the large number of production channels (>20,000) we have developed a custom ceramic package with a very thin 0.3 mm quartz window with Kyocera. Each package holds 8 channels of SiPMs. Here we report on the final SiPM parameters of the 2014 preproduction run from Hamamatsu (HPK) who has produced a series of 175 arrays with a total of 1400 SiPMs. An overview of our QA results and measurements of the photon detection efficiency, spectral response, crosstalk and cell recovery time will be discussed. - Highlights: • Uniformity of large scale SiPM production. • Small cell size SiPMs with high photo detection efficiency. • Fast recovery time SiPMs. • Custom packaging of SiPMs in High Energy Physics experiments.

  8. View through the CMS detector during the cooldown of the solenoid on February 2006

    CERN Multimedia

    Richard Breedon, UC Davis

    2006-01-01

    Image looking along the beam direction through CMS. One can see, from the inside out: the patch panels and cables for the Preshower and ECAL; the front of the endcap HCAL; some cathode strip chambers (CSCs) for detecting muons; the sealed solenoid (the first circular silver-coloured ring) currently being cooled to operating temperature and held by the central barrel yoke ring (red and orange); one of the other barrel yoke rings installed with many muon chambers (silver rectangular boxes).

  9. Design of the new front-end electronics for the readout of the upgraded CMS electromagnetic calorimeter for the HL-LHC

    CERN Document Server

    Cometti, Simona

    2017-01-01

    The Compact Muon Solenoid detector was originally designed to operate for about ten years, for LHC instantaneous luminosities up to $1 \\cdot 10^{34}$ cm$^{-2}$ s$^{-1}$ and integrated luminosity of 500 fb$^{-1}$. The High Luminosity LHC will increase the instantaneous luminosity by about a factor of 5 from current levels and CMS will accumulate an integrated luminosity of 3000 fb$^{-1}$ by about 2035. With such high luminosity the electromagnetic calorimeter of CMS will have to cope with a challenging increase in the number of interactions per bunch crossing and in radiation levels. The front-end readout electronics will be completely redesigned, with the goals of providing precision timing, low noise and added flexibility in the trigger system. It will use a faster pre-amplifier, increase the sampling frequency from 40 MS/s to 160 MS/s and implement a trigger system that resides entirely off-detector.

  10. An approach for high voltage power supply system for HCAL of LHCb experiment

    International Nuclear Information System (INIS)

    Cimpean, A.; Dumitru, D.; Kluger, A.; Magureanu, C.; Tarta, D.; Coca, C.; Orlandea, M.; Popescu, S.

    2003-01-01

    The main aim of the calorimeter system of the LHCb (Large Hadron Collider Beauty) experiment dedicated to precision measurements of CP violation and rare phenomena is to provide identification of the electrons, hadrons and photons, for the level-0 trigger and offline analysis with measurements of position and energy. The system consists in a scintillator pad/preshower (SPD/PS) detector, an electromagnetic calorimeter (ECAL) and a hadron calorimeter (HCAL), all the sub-detectors having a similar technology with scintillating tiles as active material and being read out via wavelength-shifting fibers and with an identical readout electronics for ECAL and HCAL and similar electronics for the PS. During 1997-1999 a computer controlled High Voltage (HV) distribution scheme was developed by Horia Hulubei National Institute for Physics and Nuclear Engineering (IFIN-HH) group and used to supply the PMTs of half HCAL prototype during the beam tests (1998-2000). This scheme consisted of three parts: 1) a control box which includes low voltage power supply, the RS232 interface to a PC and three modules of high voltage power supply; 2) two types of multichannel HV distributors with an individual voltage setting; 3) a software package to control all settings and refresh them periodically. Based on the acquired experience, a new design for a High Voltage Power Supply (HVPS) which satisfies the LHCb requirements has been developed for PMTs of the hadron calorimeter. The demands of this system are simplicity and low cost. This HVPS with multiple outputs (HV for photocathode and D1 - D4 dynodes) is destined to supply, with the same high voltage, groups of PMTs sorted by similar characteristics as gain and sensitivity. Because of the high rates (∼ 40 MHz) supported by PMTs, booster voltage sources are necessary to supply current for the last 4 dynodes. The box has 5 HV power supplies for photocathodes and the last 4 dynodes, each HV power supply being followed by a 4 channel

  11. Operation and Monitoring of the CMS Regional Calorimeter Trigger Hardware

    CERN Document Server

    Klabbers, P

    2008-01-01

    The electronics for the Regional Calorimeter Trigger (RCT) of the Compact Muon Solenoid Experiment (CMS) have been produced, tested, and installed. The RCT hardware consists of one clock distribution crate and 18 double-sided crates containing custom boards, ASICs, and backplanes. The RCT receives 8-bit energies and a data quality bit from the HCAL and ECAL Trigger Primitive Generators (TPGs) and sends it to the CMS Global Calorimeter Trigger (GCT) after processing. Integration tests with the TPG and GCT subsystems have been successful. Installation is complete and the RCT is integrated into the Level-1 Trigger chain. Data taking has begun using detector noise, cosmic rays, proton-beam debris, and beamhalo muons. The operation and configuration of the RCT is a completely automated process. The tools to monitor, operate, and debug the RCT are mature and will be described in detail, as well as the results from data taking with the RCT.

  12. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    by J. Spalding and A. Skuja

    2010-01-01

    Operations and Maintenance All HCAL sub-detectors participated throughout the recent data taking with 7 TeV collisions. A timing scan of HF was performed to optimize the timing across the detectors and to set the overall time position of the ~10-ns wide signals within the 25-ns integration time slice. This position was chosen to ensure that the trigger primitives in physics events are generated synchronously at the desired bunch crossing, while also providing discrimination between the calorimeter signals and anomalous signals due to interactions within the photomultiplier tubes. This timing discrimination is now used in the standard filter algorithms for anomalous signals. For HB and HE, once the statistics needed to assess the timing of a sufficient number of channels was accumulated, it was verified that the time settings determined with cosmic, splash events and initial collision data were appropriate for the 7 TeV collision data taking. A further fine-tuning of the HB and HE time settings will be perfo...

  13. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Spalding

    2011-01-01

    All the HCAL calorimeters are ready for data-taking in 2011 and participated fully in the cosmic running and initial beam operations in the last few weeks. Several improvements were made during the winter technical stop, including replacement of the light-guide sleeves in HF, improvements to the low voltage power connections, and separation of HF from HB and HE in the DAQ partitions. During the 2010 running a form of anomalous noise in the HF was identified as being caused by scintillation when charged particles pass through a portion of the air light-guide sleeve. This portion was constructed from a non-conductive mirror-like material called “HEM”. To suppress these anomalous signals, during the recent winter technical stop all sleeves in the detector were replaced with sleeves made of Tyvek. The detector has been recommissioned with all channels fully operational. Recalibration of the detector will be required due to the differing reflectivity of the new sleeves compared with the HEM sl...

  14. Precision Physics and Searches with Top and Bottom Quarks

    International Nuclear Information System (INIS)

    Garcia-Bellido, Aran

    2016-01-01

    This report goes into detail about all of the topics that were worked on by the research group from July 2015 to July 2016. The topics are: Search for supersymmetry in the all-jets final state using @@ T , measurement of the $t\\bardifferential cross section in CMS Run 2, B-physics leadership, CMS HCAL operations, CMS HCAL detector upgrade. In addition to detailing these topics, publications are listed which came from this research group.

  15. The CMS Tracker Readout Front End Driver

    CERN Document Server

    Foudas, C.; Ballard, D.; Church, I.; Corrin, E.; Coughlan, J.A.; Day, C.P.; Freeman, E.J.; Fulcher, J.; Gannon, W.J.F.; Hall, G.; Halsall, R.N.J.; Iles, G.; Jones, J.; Leaver, J.; Noy, M.; Pearson, M.; Raymond, M.; Reid, I.; Rogers, G.; Salisbury, J.; Taghavi, S.; Tomalin, I.R.; Zorba, O.

    2004-01-01

    The Front End Driver, FED, is a 9U 400mm VME64x card designed for reading out the Compact Muon Solenoid, CMS, silicon tracker signals transmitted by the APV25 analogue pipeline Application Specific Integrated Circuits. The FED receives the signals via 96 optical fibers at a total input rate of 3.4 GB/sec. The signals are digitized and processed by applying algorithms for pedestal and common mode noise subtraction. Algorithms that search for clusters of hits are used to further reduce the input rate. Only the cluster data along with trigger information of the event are transmitted to the CMS data acquisition system using the S-LINK64 protocol at a maximum rate of 400 MB/sec. All data processing algorithms on the FED are executed in large on-board Field Programmable Gate Arrays. Results on the design, performance, testing and quality control of the FED are presented and discussed.

  16. Commissioning of Upgrade Forward Hadron Calorimeters of CMS

    CERN Document Server

    Bilki, Burak

    2016-01-01

    The CMS experiment at the Large Hadron Collider (LHC) at CERN is upgrading the photo-detection and readout system of the forward hadron calorimeter (HF). During Long Shutdown 1, all of the original PMTs were replaced with multi-anode, thin window photomultipliers. At the same time, the back-end readout system was upgraded to micro-TCA readout. Here we report on the experience with commissioning and calibrating the HF front-end as well as the online operational challenges of the micro-TCA system.

  17. The CMS Beam Halo Monitor electronics

    International Nuclear Information System (INIS)

    Tosi, N.; Fabbri, F.; Montanari, A.; Torromeo, G.; Dabrowski, A.E.; Orfanelli, S.; Grassi, T.; Hughes, E.; Mans, J.; Rusack, R.; Stifter, K.; Stickland, D.P.

    2016-01-01

    The CMS Beam Halo Monitor has been successfully installed in the CMS cavern in LHC Long Shutdown 1 for measuring the machine induced background for LHC Run II. The system is based on 40 detector units composed of synthetic quartz Cherenkov radiators coupled to fast photomultiplier tubes (PMTs). The readout electronics chain uses many components developed for the Phase 1 upgrade to the CMS Hadronic Calorimeter electronics, with dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal is digitized by a charge integrating ASIC (QIE10), providing both the signal rise time, with few nanosecond resolution, and the charge integrated over one bunch crossing. The backend electronics uses microTCA technology and receives data via a high-speed 5 Gbps asynchronous link. It records histograms with sub-bunch crossing timing resolution and is read out via IPbus using the newly designed CMS data acquisition for non-event based data. The data is processed in real time and published to CMS and the LHC, providing online feedback on the beam quality. A dedicated calibration monitoring system has been designed to generate short triggered pulses of light to monitor the efficiency of the system. The electronics has been in operation since the first LHC beams of Run II and has served as the first demonstration of the new QIE10, Microsemi Igloo2 FPGA and high-speed 5 Gbps link with LHC data

  18. Electronics and Calibration system for the CMS Beam Halo Monitor

    CERN Document Server

    Tosi, Nicolò; Fabbri, Franco L; Finkel, Alexey; Orfanelli, Stella; Loos, R; Montanari, Alessandro; Rusack, R; Stickland, David P

    2014-01-01

    In the context of increasing luminosity of LHC, it will be important to accurately measure the Machine Induced Background. A new monitoring system will be installed in the cavern of the Compact Muon Solenoid (CMS) experiment for measuring the beam background at high radius. This detector is composed of synthetic quartz Cherenkov radiators, coupled to fast photomultiplier tubes (PMT). The readout chain of this detector will make use of many components developed for the Phase 1 upgrade to the CMS Hadron Calorimeter electronics, with a dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal will be digitized by a charge integrating ASIC (QIE10), providing both the signal rise time and the charge integrated over one bunch crossing. The backend electronics will record bunch-by-bunch histograms, which will be published to CMS and the LHC using the newly designed CMS beam instrumentation specific DAQ. A calibration monitoring system has been designed to generate triggered pulses of...

  19. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Spalding.

    Following the shutdown activities (see previous Bulletin), the HCAL detectors were commissioned with extensive global and cosmic running. All of the 2592, 2592, and 1728 channels of HB, HE and HF, respectively, are operational. The campaign for replacing those HPDs that showed increased noise level or other anomalies in CRAFT08 was completed during last spring. So far none of the HPDs in HB and HE have shown any sign of deterioration of noise level. Only one HO HPD in one of the outer wheels (YB-1), where problems with noise discharge in magnetic field were expected, started discharging a few months ago, and its high voltage was turned off. Two other HPDs in HO YB-1 had the HV turned off due to over-current. The total number of non-functional HO channels is 83, seven of which located in YB0. Similarly ZDC is fully functional. CASTOR was installed in June, and initial commissioning carried out with the magnetic field and with first circulating beam. On the jet trigger side, we observe perfec...

  20. Status of the CMS Phase 1 Pixel Upgrade

    CERN Document Server

    Mattig, Stefan

    2014-01-01

    The silicon pixel detector is the innermost component of the CMS tracking system, providing high precision space point measurements of charged particle trajectories. Before 2018 the instantaneous luminosity of the LHC is expected to reach 2\\,$\\times 10^{34}\\,{\\rm cm^{-2}s^{-1}}$, which will significantly increase the number of interactions per bunch crossing. The current pixel detector of CMS was not designed to work efficiently in such a high occupancy environment and will be degraded by substantial data-loss introduced by buffer filling in the analog Read-Out Chip (ROC) and effects of radiation damage in the sensors, built up over the operational period. To maintain a high tracking efficiency, CMS has planned to replace the current pixel system during ``Phase 1'' (2016/17) by a new lightweight detector, equipped with an additional 4th layer in the barrel, and one additional forward/backward disk. A new digital ROC has been designed, with increased buffers to minimize data-loss, and a digital read-out protoc...

  1. Macro Pixel ASIC (MPA): The readout ASIC for the pixel-strip (PS) module of the CMS outer tracker at HL-LHC

    CERN Document Server

    Ceresa, Davide; Kloukinas, Konstantinos; Jan Kaplon; Bialas, Wojciech; Re, Valerio; Traversi, Gianluca; Gaioni, Luigi; Ratti, Lodovico

    2014-01-01

    The CMS tracker at HL-LHC is required to provide prompt information on particles with high transverse momentum to the central Level\\,1 trigger. For this purpose, the innermost part of the outer tracker is based on a combination of a pixelated sensor with a short strip sensor, the so-called Pixel-Strip module (PS). The readout of these sensors is carried out by distinct ASICs, the Strip Sensor ASIC (SSA), for the strip layer, and the Macro Pixel ASIC (MPA) for the pixel layer. The processing of the data directly on the front-end module represents a design challenge due to the large data volume (30720\\,pixels and 1920\\,strips per module) and the limited power budget. This is the reason why several studies have been carried out to find the best compromise between ASICs performance and power consumption. This paper describes the current status of the MPA ASIC development where the logic for generating prompt information on particles with high transverse momentum is implemented. An overview of the readout method i...

  2. The Philosophy and Feasibility of Dual Readout Calorimetry

    International Nuclear Information System (INIS)

    Hauptman, John

    2006-01-01

    I will discuss the general physical ideas behind dual-readout calorimetry, their implementation in DREAM (Dual REAdout Module) with exact separation of scintillation and Cerenkov light, implementation with mixed light in DREAM fibers, anticipated implementation in PbWO4 crystals with applications to the 4th Concept detector and to CMS, use in high energy gamma-ray and cosmic ray astrophysics with Cerenkov and N2 fluorescent light, and implementation in the 4th Concept detector for muon identification

  3. Noise Reduction Effect of Multiple-Sampling-Based Signal-Readout Circuits for Ultra-Low Noise CMOS Image Sensors

    Directory of Open Access Journals (Sweden)

    Shoji Kawahito

    2016-11-01

    Full Text Available This paper discusses the noise reduction effect of multiple-sampling-based signal readout circuits for implementing ultra-low-noise image sensors. The correlated multiple sampling (CMS technique has recently become an important technology for high-gain column readout circuits in low-noise CMOS image sensors (CISs. This paper reveals how the column CMS circuits, together with a pixel having a high-conversion-gain charge detector and low-noise transistor, realizes deep sub-electron read noise levels based on the analysis of noise components in the signal readout chain from a pixel to the column analog-to-digital converter (ADC. The noise measurement results of experimental CISs are compared with the noise analysis and the effect of noise reduction to the sampling number is discussed at the deep sub-electron level. Images taken with three CMS gains of two, 16, and 128 show distinct advantage of image contrast for the gain of 128 (noise(median: 0.29 e−rms when compared with the CMS gain of two (2.4 e−rms, or 16 (1.1 e−rms.

  4. VIPRAM_L1CMS: a 2-Tier 3D Architecture for Pattern Recognition for Track Finding

    Energy Technology Data Exchange (ETDEWEB)

    Hoff, J. R. [Fermilab; Joshi, Joshi,S. [Northwestern U.; Liu, Liu, [Fermilab; Olsen, J. [Fermilab; Shenai, A. [Fermilab

    2017-06-15

    In HEP tracking trigger applications, flagging an individual detector hit is not important. Rather, the path of a charged particle through many detector layers is what must be found. Moreover, given the increased luminosity projected for future LHC experiments, this type of track finding will be required within the Level 1 Trigger system. This means that future LHC experiments require not just a chip capable of high-speed track finding but also one with a high-speed readout architecture. VIPRAM_L1CMS is 2-Tier Vertically Integrated chip designed to fulfill these requirements. It is a complete pipelined Pattern Recognition Associative Memory (PRAM) architecture including pattern recognition, result sparsification, and readout for Level 1 trigger applications in CMS with 15-bit wide detector addresses and eight detector layers included in the track finding. Pattern recognition is based on classic Content Addressable Memories with a Current Race Scheme to reduce timing complexity and a 4-bit Selective Precharge to minimize power consumption. VIPRAM_L1CMS uses a pipelined set of priority-encoded binary readout structures to sparsify and readout active road flags at frequencies of at least 100MHz. VIPRAM_L1CMS is designed to work directly with the Pulsar2b Architecture.

  5. Front-end electronics for the CMS preshower detector

    CERN Document Server

    Go, A; Barney, D; Bloch, P; Peisert, Anna; Löfstedt, B; Reynaud, S; Borkar, S; Lalwani, S

    2002-01-01

    The front-end readout system PACE2 for the CMS preshower detector consists of two chips: Delta is a 32 channel preamplifier and shaper that provides low noise, charge to voltage readout for large capacitive silicon sensors over a large dynamic range (up to 400 MIPs); PACE-AM contains a 32-channel wide, 160-cell deep, analog memory with a 32 to 1 multiplexer for serial readout. These chips are designed in .8 mu m BiCMOS DMILL radiation tolerant technology. The performance in terms of dynamic range, linearity, noise, peaking time and memory uniformity are presented. (4 refs).

  6. Development of pixel readout integrated circuits for extreme rate and radiation

    CERN Multimedia

    Liberali, V; Rizzi, A; Re, V; Minuti, M; Pangaud, P; Barbero, M B; Pacher, L; Kluit, R; Hinchliffe, I; Manghisoni, M; Giubilato, P; Faccio, F; Pernegger, H; Krueger, H; Gensolen, F D; Bilei, G M; Da rocha rolo, M D; Prydderch, M L; Fanucci, L; Grillo, A A; Bellazzini, R; Palomo pinto, F R; Michelis, S; Huegging, F G; Kishishita, T; Marchiori, G; Christian, D C; Kaestli, H C; Meier, B; Andreazza, A; Key-charriere, M; Linssen, L; Dannheim, D; Conti, E; Hemperek, T; Menouni, M; Fougeron, D; Genat, J; Bomben, M; Marzocca, C; Demaria, N; Mazza, G; Van bakel, N A; Palla, F; Grippo, M T; Magazzu, G; Ratti, L; Abbaneo, D; Crescioli, F; Deptuch, G W; Neue, G; De robertis, G; Passeri, D; Placidi, P; Gromov, V; Morsani, F; Paccagnella, A; Christiansen, J; Dho, E; Wermes, N; Rymaszewski, P; Rozanov, A; Wang, A; Lipton, R J; Havranek, M; Neviani, A; Marconi, S; Karagounis, M; Godiot, S; Calderini, G; Seidel, S C; Horisberger, R P; Garcia-sciveres, M A; Stabile, A; Beccherle, R; Bacchetta, N

    The present hybrid pixel detectors in operation at the LHC represent a major achievement. They deployed a new technology on an unprecedented scale and their success firmly established pixel tracking as indispensable for future HEP experiments. However, extrapolation of hybrid pixel technology to the HL-LHC presents major challenges on several fronts. We propose a new RD collaboration specifically focused on the development of pixel readout Integrated Circuits (IC). The IC challenges include: smaller pixels to resolve tracks in boosted jets, much higher hit rates (1-2 GHz/cm$^{2}$), unprecedented radiation tolerance (10 MGy), much higher output bandwidth, and large IC format with low power consumption in order to instrument large areas while keeping the material budget low. We propose a collaboration to design the next generation of hybrid pixel readout chips to enable the ATLAS and CMS Phase 2 pixel upgrades. This does not imply that ATLAS and CMS must use the same exact pixel readout chip, as most of the dev...

  7. Status of the CMS Phase I pixel detector upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Spannagel, S., E-mail: simon.spannagel@desy.de

    2016-09-21

    A new pixel detector for the CMS experiment is being built, owing to the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking while featuring a significantly reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and comprises a low-threshold comparator. These improvements allow the new pixel detector to sustain and improve the efficiency of the current pixel tracker at the increased requirements imposed by high luminosities and pile-up. This contribution gives an overview of the design of the upgraded pixel detector and the status of the upgrade project, and presents test beam performance measurements of the production read-out chip.

  8. Status of the CMS Phase I Pixel Detector Upgrade

    CERN Document Server

    Spannagel, Simon

    2016-09-21

    A new pixel detector for the CMS experiment is being built, owing to the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking while featuring a significantly reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and comprises a low-threshold comparator. These improvements allow the new pixel detector to sustain and improve the efficiency of the current pixel tracker at the increased requirements imposed by high luminosities and pile-up. This contribution gives an overview of the design of the upgraded pixel detector and the status of the upgrade project, and presents test beam performance measurements of the production read-out chip.

  9. The CMS Outer Hadron Calorimeter

    CERN Document Server

    Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Bawa, Harinder Singh; Beri, Suman Bala; Bhandari, Virender; Bhatnagar, Vipin; Chendvankar, Sanjay; Deshpande, Pandurang Vishnu; Dugad, Shashikant; Ganguli, Som N; Guchait, Monoranjan; Gurtu, Atul; Kalmani, Suresh Devendrappa; Kaur, Manjit; Kohli, Jatinder Mohan; Krishnaswamy, Marthi Ramaswamy; Kumar, Arun; Maity, Manas; Majumder, Gobinda; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Narasimham, Vemuri Syamala; Patil, Mandakini Ravindra; Reddy, L V; Satyanarayana, B; Sharma, Seema; Singh, B; Singh, Jas Bir; Sudhakar, Katta; Tonwar, Suresh C; Verma, Piyush

    2006-01-01

    The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with a outer calorimeter to ensure high energy shower containment in CMS and thus working as a tail catcher. Fabrication, testing and calibrations of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing $\\et$ measurements at LHC energies. The outer hadron calorimeter has a very good signal to background ratio even for a minimum ionising particle and can hence be used in coincidence with the Resistive Plate Chambers of the CMS detector for the muon trigger.

  10. Construction and commissioning of the Phase 1 upgrade of the CMS pixel detector

    CERN Document Server

    Bartek, Rachel

    2017-01-01

    The Phase 1 upgrade of the CMS pixel detector, installed by the CMS collaboration during the recent extended end-of-year technical stop, is built out of four barrel layers (BPIX) and three forward disks in each endcap (FPIX). It comprises a total of 124M pixel channels, in 1,856 modules and it is designed to withstand instantaneous luminosities of up to $2 \\rm{x} 10^{34} \\rm{cm}^{-2} \\rm{s}^{-1}$ with increased detector acceptance and additional redundancy for the tracking, while at the same time reducing the material budget. These goals are achieved using a new readout chip and modified powering and readout schemes, one additional tracking layer both in the barrel and in the disks, and new detector supports including a $\\rm{CO}_2$ based evaporative cooling system. Different parts of the detector have been assembled over the last year and later brought to CERN for installation inside the CMS tracker. At various stages during the assembly tests have been performed to ensure that the readout and power electro...

  11. New Fast Beam Conditions Monitoring (BCM1F) system for CMS

    Science.gov (United States)

    Zagozdzinska, A. A.; Bell, A. J.; Dabrowski, A. E.; Hempel, M.; Henschel, H. M.; Karacheban, O.; Przyborowski, D.; Leonard, J. L.; Penno, M.; Pozniak, K. T.; Miraglia, M.; Lange, W.; Lohmann, W.; Ryjov, V.; Lokhovitskiy, A.; Stickland, D.; Walsh, R.

    2016-01-01

    The CMS Beam Radiation Instrumentation and Luminosity (BRIL) project is composed of several systems providing the experiment protection from adverse beam conditions while also measuring the online luminosity and beam background. Although the readout bandwidth of the Fast Beam Conditions Monitoring system (BCM1F—one of the faster monitoring systems of the CMS BRIL), was sufficient for the initial LHC conditions, the foreseen enhancement of the beams parameters after the LHC Long Shutdown-1 (LS1) imposed the upgrade of the system. This paper presents the new BCM1F, which is designed to provide real-time fast diagnosis of beam conditions and instantaneous luminosity with readout able to resolve the 25 ns bunch structure.

  12. Commissioning and first results from the CMS phase-1 upgrade pixel detector

    CERN Document Server

    Sonneveld, Jorine Mirjam

    2017-01-01

    The phase~1 upgrade of the CMS pixel detector has been designed to maintain the tracking performance at instantaneous luminosities of $2 \\times 10^{34} \\mathrm{~cm}^{-2} \\mathrm{~s}^{-1}$. Both barrel and endcap disk systems now feature one extra layer (4 barrel layers and 3 endcap disks), and a digital readout that provides a large enough bandwidth to read out its 124M pixel channels (87.7 percent more pixels compared to the previous system). The backend control and readout systems have been upgraded accordingly from VME-based to micro-TCA-based ones. The detector is now also fitted with a bi-phase CO$_2$ cooling system that reduces the material budget in the tracking region. The detector has been installed inside CMS at the start of 2017 and is now taking data. These proceedings discuss experiences in the commissioning and operation of the CMS phase~1 pixel detector. The first results from the CMS phase~1 pixel detector with this year's LHC proton-proton collision data are presented. ...

  13. Development of pixel readout integrated circuits for extreme rate and radiation

    CERN Document Server

    Garcia-Sciveres, M; CERN. Geneva. The LHC experiments Committee; LHCC

    2013-01-01

    Letter of Intent for RD Collaboration Proposal focused on development of a next generation pixel readout integrated circuits needed for high luminosity LHC detector upgrades. Brings together ATLAS and CMS pixel chip design communities.

  14. Contribution to the study of the readout of the electromagnetic calorimeter crystals in the CMS experiment at LHC; Contribution a l`etude de la lecture des cristaux du calorimetre electromagnetique de l`experience CMS au LHC

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Franck [Universite Claude Bernard Lyon-1, 69 - Lyon (France)

    1998-07-03

    The search for neutral Higgs boson through its decay into two photons provides a very promising signal for a mass between 90 and 150 GeV. It requires an electromagnetic calorimeter of very high resolution. The CMS (Compact Muon Solenoid) electromagnetic calorimeter must be made up of more than 80,000 lead tungstate crystals. In the central part (the barrel), the scintillation light readout is performed by means of avalanche photodiodes, a silicon photo-sensor with internal gain which is a relative novelty in high energy physics. Concerning the readout electronics, the energy available in the centre-of-mass (14 TeV) as well as the collision frequency (40 MHz) of LHC impose constraints with respect to the signal treatment up to the acquisition. The retained solution consists in pairing two avalanche photodiodes, the parameters of which (gain, temperature dependence, dark current, etc) must be controlled, and coupling them to a low noise preamplifier of high dynamical range (5 MeV - 2 TeV) followed by a four-slopes linear compressor and a analog-digital sampling converter of 12 bits, 40 MHz. The thesis presents the prototypes of different electromagnetic calorimeters tested in the high energy beam. An energy resolution of 0.6% at 100 GeV was obtained with a conventional readout circuitry, while the integrated associated circuits were radiation resistant 73 refs., 100 figs., 19 tabs.

  15. Phase I Upgrade of the CMS Hadron Calorimeter

    CERN Document Server

    Cooper, Seth Isaac

    2014-01-01

    In preparation for Run 2 (2015) and Run 3 of the LHC (2019), the CMS hadron calorimeter has begun a series of ambitious upgrades. These include new photodetectors in addition to improved front-end and back-end readout electronics. In the hadron forward calorimeter, the existing photomultiplier tubes are being replaced with thinner window, multi-anode readout models, while in the central region, the hybrid photodiodes will be replaced with silicon photomultipliers. The front-end electronics will include high precision timing readout, and the backend electronics will handle the increased data bandwidth. The barrel and endcap longitudinal segmentation will also be increased. This report will describe the motivation for the upgrade, its major components, and its current status.

  16. Electronic calibration developed for the CMS electromagnetic calorimeter

    CERN Document Server

    Baek, Y W; David, P Y; Ditta, J; Hermel, V; Fouque, N; Mendiburu, J P; Nédélec, P; Peigneux, J P; Poireau, V; Rebecchi, P; Silou, D

    2004-01-01

    An electronic system, designed to provide a relative calibration for the readout of the CMS electromagnetic calorimeter (CMS-ECAL), is described. On request, this system injects a pulse at the input of a predetermined group of preamplifiers with preselected amplitude and a shape identical to the one produced by the photodetectors. Several chips, in DMILL 0.8 mu m technology, have been developed for integration on the front-end electronics. We describe the principle, the testing, the measurement of their precision, and radiation hardness. (6 refs).

  17. Radiation testing of electronics for the CMS endcap muon system

    Energy Technology Data Exchange (ETDEWEB)

    Bylsma, B. [Ohio State University (United States); Cady, D.; Celik, A. [Texas A and M University, College Station, TX 77843 (United States); Durkin, L.S. [Ohio State University (United States); Gilmore, J., E-mail: gilmore@tamu.edu [Texas A and M University, College Station, TX 77843 (United States); Haley, J. [Northeastern University (United States); Khotilovich, V.; Lakdawala, S. [Texas A and M University, College Station, TX 77843 (United States); Liu, J.; Matveev, M.; Padley, B.P.; Roberts, J. [Rice University (United States); Roe, J.; Safonov, A.; Suarez, I. [Texas A and M University, College Station, TX 77843 (United States); Wood, D. [Northeastern University (United States); Zawisza, I. [Texas A and M University, College Station, TX 77843 (United States)

    2013-01-11

    The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause permanent damage to the electronic circuitry, as well as temporary effects such as data corruption induced by Single Event Upsets. Once the High Luminosity LHC (HL-LHC) accelerator upgrades are completed it will have five times higher instantaneous luminosity than LHC, allowing for detection of rare physics processes, new particles and interactions. Tests have been performed to determine the effects of radiation on the electronic components to be used for the Endcap Muon electronics project currently being designed for installation in the CMS experiment in 2013. During these tests the digital components on the test boards were operating with active data readout while being irradiated with 55 MeV protons. In reactor tests, components were exposed to 30 years equivalent levels of neutron radiation expected at the HL-LHC. The highest total ionizing dose (TID) for the muon system is expected at the innermost portion of the CMS detector, with 8900 rad over 10 years. Our results show that Commercial Off-The-Shelf (COTS) components selected for the new electronics will operate reliably in the CMS radiation environment.

  18. Radiation testing of electronics for the CMS endcap muon system

    Science.gov (United States)

    Bylsma, B.; Cady, D.; Celik, A.; Durkin, L. S.; Gilmore, J.; Haley, J.; Khotilovich, V.; Lakdawala, S.; Liu, J.; Matveev, M.; Padley, B. P.; Roberts, J.; Roe, J.; Safonov, A.; Suarez, I.; Wood, D.; Zawisza, I.

    2013-01-01

    The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause permanent damage to the electronic circuitry, as well as temporary effects such as data corruption induced by Single Event Upsets. Once the High Luminosity LHC (HL-LHC) accelerator upgrades are completed it will have five times higher instantaneous luminosity than LHC, allowing for detection of rare physics processes, new particles and interactions. Tests have been performed to determine the effects of radiation on the electronic components to be used for the Endcap Muon electronics project currently being designed for installation in the CMS experiment in 2013. During these tests the digital components on the test boards were operating with active data readout while being irradiated with 55 MeV protons. In reactor tests, components were exposed to 30 years equivalent levels of neutron radiation expected at the HL-LHC. The highest total ionizing dose (TID) for the muon system is expected at the innermost portion of the CMS detector, with 8900 rad over 10 years. Our results show that Commercial Off-The-Shelf (COTS) components selected for the new electronics will operate reliably in the CMS radiation environment.

  19. Digital HCAL Electronics: Status of Production

    Energy Technology Data Exchange (ETDEWEB)

    Drake, Gary; Repond, Jose, E-mail: drake@hep.anl.gov [Argonne National Laboratory (United States)

    2011-04-01

    This is a status report of the production of the readout electronics for the Digital Hadron Calorimeter (DHCAL) prototype. The prototype will be equipped with Resistive Plate Chambers (RPCs), read out with 1 x 1 cm{sup 2} pads. The readout of each channel is simplified to provide a yes or no (digital readout) within a time bin of 100 ns. Each detector layer with an area of 96 x 96 cm{sup 2} contains close to 10,000 readout channels. The total channel count for the entire prototype calorimeter with 38 active layers is approximately 350,000.

  20. CMS Silicon Strip Tracker Performance

    CERN Document Server

    Agram, Jean-Laurent

    2012-01-01

    The CMS Silicon Strip Tracker (SST), consisting of 9.6 million readout channels from 15148 modules and covering an area of 198 square meters, needs to be precisely calibrated in order to correctly reconstruct the events recorded. Calibration constants are derived from different workflows, from promptly reconstructed events with particles as well as from commissioning events gathered just before the acquisition of physics runs. The performance of the SST has been carefully studied since the beginning of data taking: the noise of the detector, data integrity, signal-over-noise ratio, hit reconstruction efficiency and resolution have been all investigated with time and for different conditions. In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

  1. CMS DAQ Event Builder Based on Gigabit Ethernet

    CERN Document Server

    Bauer, G; Branson, J; Brett, A; Cano, E; Carboni, A; Ciganek, M; Cittolin, S; Erhan, S; Gigi, D; Glege, F; Gómez-Reino, Robert; Gulmini, M; Gutiérrez-Mlot, E; Gutleber, J; Jacobs, C; Kim, J C; Klute, M; Lipeles, E; Lopez-Perez, Juan Antonio; Maron, G; Meijers, F; Meschi, E; Moser, R; Murray, S; Oh, A; Orsini, L; Paus, C; Petrucci, A; Pieri, M; Pollet, L; Rácz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Sumorok, K; Suzuki, I; Tsirigkas, D; Varela, J

    2007-01-01

    The CMS Data Acquisition System is designed to build and filter events originating from 476 detector data sources at a maximum trigger rate of 100 KHz. Different architectures and switch technologies have been evaluated to accomplish this purpose. Events will be built in two stages: the first stage will be a set of event builders called FED Builders. These will be based on Myrinet technology and will pre-assemble groups of about 8 data sources. The second stage will be a set of event builders called Readout Builders. These will perform the building of full events. A single Readout Builder will build events from 72 sources of 16 KB fragments at a rate of 12.5 KHz. In this paper we present the design of a Readout Builder based on TCP/IP over Gigabit Ethernet and the optimization that was required to achieve the design throughput. This optimization includes architecture of the Readout Builder, the setup of TCP/IP, and hardware selection.

  2. Performance of the CMS Phase 1 Pixel Detector

    CERN Document Server

    Akgun, Bora

    2018-01-01

    It is anticipated that the LHC accelerator will reach and exceed the luminosity of L = 2$\\times$10$^{34}$cm$^{-2}$s$^{-1}$ during the LHC Run 2 period until 2023. At this higher luminosity and increased hit occupancies the CMS phase-0 pixel detector would have been subjected to severe dead time and inefficiencies introduced by limited buffers in the analog read-out chip and effects of radiation damage in the sensors. Therefore a new pixel detector has been built and replaced the phase-0 detector in the 2016/17 LHC extended year-end technical stop. The CMS phase-1 pixel detector features four central barrel layers and three end-cap disks in forward and backward direction for robust tracking performance, and a significantly reduced overall material budget including new cooling and powering schemes. The design of the new front-end readout chip comprises larger data buffers, an increased transmission bandwidth, and low-threshold comparators. These improvements allow the new pixel detector to sustain and improve t...

  3. The CMS all silicon Tracker simulation

    CERN Document Server

    Biasini, Maurizio

    2009-01-01

    The Compact Muon Solenoid (CMS) tracker detector is the world's largest silicon detector with about 201 m$^2$ of silicon strips detectors and 1 m$^2$ of silicon pixel detectors. It contains 66 millions pixels and 10 million individual sensing strips. The quality of the physics analysis is highly correlated with the precision of the Tracker detector simulation which is written on top of the GEANT4 and the CMS object-oriented framework. The hit position resolution in the Tracker detector depends on the ability to correctly model the CMS tracker geometry, the signal digitization and Lorentz drift, the calibration and inefficiency. In order to ensure high performance in track and vertex reconstruction, an accurate knowledge of the material budget is therefore necessary since the passive materials, involved in the readout, cooling or power systems, will create unwanted effects during the particle detection, such as multiple scattering, electron bremsstrahlung and photon conversion. In this paper, we present the CM...

  4. Production chain of CMS pixel modules

    CERN Multimedia

    2006-01-01

    The pictures show the production chain of pixel modules for the CMS detector. Fig.1: overview of the assembly procedure. Fig.2: bump bonding with ReadOut Chip (ROC) connected to the sensor. Fig.3: glueing a raw module onto the baseplate strips. Fig.4: glueing of the High Density Interconnect (HDI) onto a raw module. Fig.5: pull test after heat reflow. Fig.6: wafer sensor processing, Indium evaporation.

  5. RD Collaboration Proposal: Development of pixel readout integrated circuits for extreme rate and radiation

    CERN Document Server

    Chistiansen, J (CERN)

    2013-01-01

    This proposal describes a new RD collaboration to develop the next genrration of hybrid pixel readout chips for use in ATLAS and CMS PHase 2 upgrades. extrapolation of hybrid pixel technology to the HL-LHC presents major challenges on several fronts. Challenges include: smaller pixels to resolve tracks in boosted jets, much higher hit rates (1-2 GHz/cm2 ), unprecedented radiation tolerance (10 MGy), much higher output bandwidth, and large IC format with low power consumption in order to instrument large areas while keeping the material budget low. This collaboration is specifically focused on design of hybrid pixel readout chips, and not on more general chip design or on other aspects of hybrid pixel technology. Participants include 7 institutes on ATLAS and 7 on CMS, plus 2 on both experiments.

  6. Study of the CMS Phase-1 Pixel Pilot Blade Reconstruction

    CERN Document Server

    Vami, Tamas Almos

    2017-01-01

    The Compact Muon Solenoid (CMS) detector is one of two general-purpose detectors that measure the products of high energy particle interactions in the Large Hadron Collider (LHC) at CERN. The silicon pixel detector is the innermost component of the CMS tracking system. The detector which was in operation between 2009 and 2016 has now been replaced with an upgraded one in the beginning of 2017. During the previous shutdown period of the LHC, a prototype readout system and a third disk was inserted into the old forward pixel detector with eight prototype blades constructed using the new digital read-out chips. Testing the performance of these pilot modules enabled us to gain operational experience with the upgraded detector. In this paper, the reconstruction and analysis of the data taken with the new modules are presented including information on the calibration of the reconstruction software. The hit finding efficiency and track-hit residual distributions are also shown.

  7. Radiation Testing of Electronics for the CMS Endcap Muon System

    CERN Document Server

    INSPIRE-00070357; Celik, A.; Durkin, L.S.; Gilmore, J.; Haley, J.; Khotilovich, V.; Lakdawala, S.; Liu, J.; Matveev, M.; Padley, B.P.; Roberts, J.; Roe, J.; Safonov, A.; Suarez, I.; Wood, D.; Zawisza, I.

    2013-01-01

    The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause permanent damage to the electronic circuitry, as well as temporary effects such as data corruption induced by Single Event Upsets. Once the High Luminosity LHC (HL-LHC) accelerator upgrades are completed it will have five times higher instantaneous luminosity than LHC, allowing for detection of rare physics processes, new particles and interactions. Tests have been performed to determine the effects of radiation on the electronic components to be used for the Endcap Muon electronics project currently being designed for installation in the CMS experiment in 2013. During these tests the digital components on the test boards were operating with active data readout while being irradiated with 55 MeV protons. In reactor tests, components were exposed to 30 years equivalent levels o...

  8. CMS Forward Pixel Upgrade Electronics and System Testing

    CERN Document Server

    Weber, Hannsjorg Artur

    2016-01-01

    This note discusses results of electronics and system testing of the CMS forward pixel (FPIX) detector upgrade for Phase 1. The FPIX detector is comprised of four stand-alone half cylinders, each of which contains frontend readout electronic boards, power regulators, cables and fibers in addition to the pixel modules. All of the components undergo rigorous testing and quality assurance before assembly into the half cylinders. Afterwards, we perform full system tests on the completely assembled half cylinders, including calibrations at final operating temperatures, characterization of the realistic readout chain, and system grounding and noise studies. The results from all these tests are discussed.

  9. MPPC Photon Sensor Operational Experience in CMS

    CERN Document Server

    Kunsken, Andreas

    2015-01-01

    The CMS Outer Hadron Calorimeter (HO) is the first large scale hadron collider detector to use SIPMs. To build the system we purchased and measured 3000 Hamamatsu MPPCs. 1656 channels of MPPC with 40MHz readout have currently been installed into CMS. We report on comparisons of in situ and vendor supplied measurements. We present results on in-situ working point optimization by IV scanning and temperature vs V scanning. We have developed several techniques for determining the breakdown voltage in situ. We compare the performance of each technique and its success in working point optimization. We present results on gain, noise, and cross talk monitoring. We present results on overall system stability.

  10. Operating characteristics of radiation-hardened silicon pixel detectors for the CMS experiment

    CERN Document Server

    Hyosung, Cho

    2002-01-01

    The Compact Muon Solenoid (CMS) experiment at the CERN Large Hadron Collider (LHC) will have forward silicon pixel detectors as its innermost tracking device. The pixel devices will be exposed to the harsh radiation environment of the LHC. Prototype silicon pixel detectors have been designed to meet the specification of the CMS experiment. No guard ring is required on the n/sup +/ side, and guard rings on the p/sup +/ side are always kept active before and after type inversion. The whole n/sup +/ side is grounded and connected to readout chips, which greatly simplifies detector assembling and improves the stability of bump-bonded readout chips on the n/sup +/ side. Operating characteristics such as the leakage current, the full depletion voltage, and the potential distributions over guard rings were tested using standard techniques. The tests are discussed in this paper. (9 refs).

  11. LHC-rate beam test of CMS pixel barrel modules

    International Nuclear Information System (INIS)

    Erdmann, W.; Hoermann, Ch.; Kotlinski, D.; Horisberger, R.; Kaestli, H. Chr.; Gabathuler, K.; Bertl, W.; Meier, B.; Langenegger, U.; Trueeb, P.; Rohe, T.

    2007-01-01

    Modules for the CMS pixel barrel detector have been operated in a high rate pion beam at PSI in order to verify under LHC-like conditions the final module design for the production. The test beam provided charged particle rates up to 10 8 cm -2 s -1 over the full module area. Bunch structure and randomized high trigger rates simulated realistic operation. A four layer telescope made of single pixel readout chip assemblies provided tracking needed for the determination of the modules hit reconstruction efficiency. The performance of the modules has been shown to be adequate for the CMS pixel barrel

  12. Study of Calorimeter Calibration with Tau's in CMS.

    CERN Document Server

    Denegri, Daniel; Nikitenko, Alexander

    1997-01-01

    We propose to calibrate in situ the CMS calorimetry using the single, isolated pions from tau-> pi nu in W -> tau nu and Z, gamma^* -> tau tau processes applying the p/E method. In case of pions non-interacting in the ECAL the method is straightforward, but for pions interacting in the ECAL care is needed to suppress and keep under control pi+- pi0's from tau's or QCS jets, which could vitiate the method. This can be achieved exploiting the ECAL granularity and tracker-calorimetry special matching. The momentum of the isolated high pt pion can be directly compared to the calorimeter measurement. Triggering of the W -> tau nu events is envisaged with a special tau-jet trigger combined with a missing transverse energy trigger. The Z gamma^* -> tau tau events could be triggered by lepton + tau-jet and double tau-jet trigger. The event rate for pt of pion > 15 GeV is e nough to calibrate each HCAL cell at a 1% precision after collection of 10^4 pb-1 of data.

  13. The CMS tracker operation and performance at the Magnet Test and Cosmic Challenge

    International Nuclear Information System (INIS)

    Adam, W; Bergauer, T; Dragicevic, M; Friedl, M; Fruehwirth, R; Haensel, S; Hrubec, J; Krammer, M; Pernicka, M; Waltenberger, W; Widl, E; Mechelen, P Van; Cardaci, M; Beaumont, W; Langhe, E de; Wolf, E A de; Delmeire, E; Bouhali, O; Charaf, O; Clerbaux, B

    2008-01-01

    During summer 2006 a fraction of the CMS silicon strip tracker was operated in a comprehensive slice test called the Magnet Test and Cosmic Challenge (MTCC). At the MTCC, cosmic rays detected in the muon chambers were used to trigger the readout of all CMS sub-detectors in the general data acquisition system and in the presence of the 4 T magnetic field produced by the CMS superconducting solenoid. This document describes the operation of the Tracker hardware and software prior, during and after data taking. The performance of the detector as resulting from the MTCC data analysis is also presented

  14. Experimental particle physics research at Texas Tech University

    International Nuclear Information System (INIS)

    Akchurin, Nural; Lee, Sung-Won; Volobouev, Igor; Wigmans, Richard

    2016-01-01

    The high energy physics group at Texas Tech University (TTU) concentrates its research efforts on the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) and on generic detector R&D for future applications. Our research programs have been continuously supported by the US Department of Energy for over two decades, and this final report summarizes our achievements during the last grant period from May 1, 2012 to March 31, 2016. After having completed the Run 1 data analyses from the CMS detector, including the discovery of the Higgs boson in July 2012, we concentrated on commissioning the CMS hadron calorimeter (HCAL) for Run 2, performing analyses of Run 2 data, and making initial studies and plans for the second phase of upgrades in CMS. Our research has primarily focused on searches for Beyond Standard Model (BSM) physics via dijets, monophotons, and monojets. We also made significant contributions to the analyses of the semileptonic Higgs decays and Standard Model (SM) measurements in Run 1. Our work on the operations of the CMS detector, especially the performance monitoring of the HCAL in Run 1, was indispensable to the experiment. Our team members, holding leadership positions in HCAL, have played key roles in the R&D, construction, and commissioning of these detectors in the last decade. We also maintained an active program in jet studies that builds on our expertise in calorimetry and algorithm development. In Run 2, we extended some of our analyses at 8 TeV to 13 TeV, and we also started to investigate new territory, e.g., dark matter searches with unexplored signatures. The objective of dual-readout calorimetry R&D was intended to explore (and, if possible, eliminate) the obstacles that prevent calorimetric detection of hadrons and jets with a comparable level of precision as we have grown accustomed to for electrons and photons. The initial prototype detector was successfully tested at the SPS/CERN in 2003-2004 and evolved over the

  15. Experimental particle physics research at Texas Tech University

    Energy Technology Data Exchange (ETDEWEB)

    Akchurin, Nural [Texas Tech Univ., Lubbock, TX (United States); Lee, Sung-Won [Texas Tech Univ., Lubbock, TX (United States); Volobouev, Igor [Texas Tech Univ., Lubbock, TX (United States); Wigmans, Richard [Texas Tech Univ., Lubbock, TX (United States)

    2016-06-22

    The high energy physics group at Texas Tech University (TTU) concentrates its research efforts on the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) and on generic detector R&D for future applications. Our research programs have been continuously supported by the US Department of Energy for over two decades, and this final report summarizes our achievements during the last grant period from May 1, 2012 to March 31, 2016. After having completed the Run 1 data analyses from the CMS detector, including the discovery of the Higgs boson in July 2012, we concentrated on commissioning the CMS hadron calorimeter (HCAL) for Run 2, performing analyses of Run 2 data, and making initial studies and plans for the second phase of upgrades in CMS. Our research has primarily focused on searches for Beyond Standard Model (BSM) physics via dijets, monophotons, and monojets. We also made significant contributions to the analyses of the semileptonic Higgs decays and Standard Model (SM) measurements in Run 1. Our work on the operations of the CMS detector, especially the performance monitoring of the HCAL in Run 1, was indispensable to the experiment. Our team members, holding leadership positions in HCAL, have played key roles in the R&D, construction, and commissioning of these detectors in the last decade. We also maintained an active program in jet studies that builds on our expertise in calorimetry and algorithm development. In Run 2, we extended some of our analyses at 8 TeV to 13 TeV, and we also started to investigate new territory, e.g., dark matter searches with unexplored signatures. The objective of dual-readout calorimetry R&D was intended to explore (and, if possible, eliminate) the obstacles that prevent calorimetric detection of hadrons and jets with a comparable level of precision as we have grown accustomed to for electrons and photons. The initial prototype detector was successfully tested at the SPS/CERN in 2003-2004 and evolved over the

  16. Power distribution studies for CMS forward tracker

    International Nuclear Information System (INIS)

    Todri, A.; Turqueti, M.; Rivera, R.; Kwan, S.

    2009-01-01

    The Electronic Systems Engineering Department of the Computing Division at the Fermi National Accelerator Laboratory is carrying out R and D investigations for the upgrade of the power distribution system of the Compact Muon Solenoid (CMS) Pixel Tracker at the Large Hadron Collider (LHC). Among the goals of this effort is that of analyzing the feasibility of alternative powering schemes for the forward tracker, including DC to DC voltage conversion techniques using commercially available and custom switching regulator circuits. Tests of these approaches are performed using the PSI46 pixel readout chip currently in use at the CMS Tracker. Performance measures of the detector electronics will include pixel noise and threshold dispersion results. Issues related to susceptibility to switching noise will be studied and presented. In this paper, we describe the current power distribution network of the CMS Tracker, study the implications of the proposed upgrade with DC-DC converters powering scheme and perform noise susceptibility analysis.

  17. IHEP in the LHCb

    CERN Multimedia

    2001-01-01

    The LHCb hadron calorimeter (HCAL), designed at IHEP, is a sampling device made out of steel and scintillating tiles readout by wavelength-shifting fibers. A total of 52 modules have to be produced to built up the two halves of the HCAL structure. IHEP took responsibility for the tiles production, assembling and testing of the modules and for precise machining of the optics components.

  18. Sensor Development for the CMS Pixel Detector

    CERN Document Server

    Rohe, T; Chiochia, V; Cremaldi, L M; Cucciarelli, S; Dorkhov, A; Konecki, M; Prokofiev, K; Regenfus, C; Sanders, D A; Son, S; Speer, T; Swartz, M

    2003-01-01

    This paper reports on a current R&D activity for the sensor part of the CMS pixel detector. Devices featuring several design and technology options have been irradiated up to a proton fluence of 1E15 (1MeV Neutron)/cm**2 at the CERN PS. Afterwards they have been bump bonded to unirradiated readout chips. The chip allows a non zero suppressed full analogue readout and therefore a good characterization of the sensors in terms of noise and charge collection properties. The samples have been tested using high energy pions in the H2 beam line of the CERN SPS in June and September 2003. The results of this test beam are presented and the differences between the sensor options are discussed.

  19. Radiation and Temperature Effects on the APV25 Readout Chip for the CMS Tracker

    CERN Document Server

    Messomo, Etam Albert Noah

    2002-01-01

    The Compact Muon Solenoid (CMS) is one of four particle detectors designed for use at the Large Hadron Collider (LHC) currently under construction at CERN, the European Laboratory for Particle Physics in Geneva. The LHC will accelerate two counterrotating beams of protons to energies of 7 TeV and produce 109 proton-proton collisions per second at a bunch-crossing frequency of 40 MHz. These collisions occuring at the centre of CMS will generate a very hostile radiation environment. The CMS sub-detector system closest to the collision point is the highly segmented Tracker, consisting of a silicon pixel detector with 45 million channels and a silicon microstrip detector with 10 million channels. The microstrip detector will be read out by the APV25, a custom-made chip manufactured in a commercial 0.25 µm CMOS microelectronics process. Radiation and temperature studies are required to ensure that the APV25 can operate reliably in the CMS environment. The radiation effects to which the APV25 could be susceptible ...

  20. Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters

    CERN Document Server

    Baiatian, G; Emeliantchik, Igor; Massolov, V; Shumeiko, Nikolai; Stefanovich, R; Damgov, Jordan; Dimitrov, Lubomir; Genchev, Vladimir; Piperov, Stefan; Vankov, Ivan; Litov, Leander; Bencze, Gyorgy; Laszlo, Andras; Pal, Andras; Vesztergombi, Gyorgy; Zálán, Peter; Fenyvesi, Andras; Bawa, Harinder Singh; Beri, Suman Bala; Bhatnagar, Vipin; Kaur, Manjit; Kohli, Jatinder Mohan; Kumar, Arun; Singh, Jas Bir; Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Chendvankar, Sanjay; Dugad, Shashikant; Kalmani, Suresh Devendrappa; Katta, S; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Patil, Mandakini Ravindra; Reddy, L; Satyanarayana, B; Sharma, Seema; Sudhakar, Katta; Verma, Piyush; Hashemi, Majid; Mohammadi-Najafabadi, M; Paktinat, S; Babich, Kanstantsin; Golutvin, Igor; Kalagin, Vladimir; Kamenev, Alexey; Konoplianikov, V; Kosarev, Ivan; Moissenz, K; Moissenz, P; Oleynik, Danila; Petrosian, A; Rogalev, Evgueni; Semenov, Roman; Sergeyev, S; Shmatov, Sergey; Smirnov, Vitaly; Vishnevskiy, Alexander; Volodko, Anton; Zarubin, Anatoli; Druzhkin, Dmitry; Ivanov, Alexander; Kudinov, Vladimir; Orlov, Alexandre; Smetannikov, Vladimir; Gavrilov, Vladimir; Gershtein, Yuri; Ilyina, N; Kaftanov, Vitali; Kisselevich, I; Kolossov, V; Krokhotin, Andrey; Kuleshov, Sergey; Litvintsev, Dmitri; Ulyanov, A; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Demianov, A; Gribushin, Andrey; Kodolova, Olga; Petrushanko, Sergey; Sarycheva, Ludmila; Teplov, V; Vardanyan, Irina; Yershov, A; Abramov, Victor; Goncharov, Petr; Kalinin, Alexey; Khmelnikov, Alexander; Korablev, Andrey; Korneev, Yury; Krinitsyn, Alexander; Kryshkin, V; Lukanin, Vladimir; Pikalov, Vladimir; Ryazanov, Anton; Talov, Vladimir; Turchanovich, L; Volkov, Alexey; Camporesi, Tiziano; de Visser, Theo; Vlassov, E; Aydin, Sezgin; Bakirci, Mustafa Numan; Cerci, Salim; Dumanoglu, Isa; Eskut, Eda; Kayis-Topaksu, A; Koylu, S; Kurt, Pelin; Onengüt, G; Ozkurt, Halil; Polatoz, A; Sogut, Kenan; Topakli, Huseyin; Vergili, Mehmet; Yetkin, Taylan; Cankoc, K; Esendemir, Akif; Gamsizkan, Halil; Güler, M; Ozkan, Cigdem; Sekmen, Sezen; Serin-Zeyrek, M; Sever, Ramazan; Yazgan, Efe; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Gülmez, Erhan; Isiksal, Engin; Kaya, Mithat; Ozkorucuklu, Suat; Levchuk, Leonid; Sorokin, Pavel; Grynev, B; Lyubynskiy, Vadym; Senchyshyn, Vitaliy; Hauptman, John M; Abdullin, Salavat; Elias, John E; Elvira, D; Freeman, Jim; Green, Dan; Los, Serguei; ODell, V; Ronzhin, Anatoly; Suzuki, Ichiro; Vidal, Richard; Whitmore, Juliana; Arcidy, M; Hazen, Eric; Heering, Arjan Hendrix; Lawlor, C; Lazic, Dragoslav; Machado, Emanuel; Rohlf, James; Varela, F; Wu, Shouxiang; Baden, Drew; Bard, Robert; Eno, Sarah Catherine; Grassi, Tullio; Jarvis, Chad; Kellogg, Richard G; Kunori, Shuichi; Mans, Jeremy; Skuja, Andris; Podrasky, V; Sanzeni, Christopher; Winn, Dave; Akgun, Ugur; Ayan, S; Duru, Firdevs; Merlo, Jean-Pierre; Mestvirishvili, Alexi; Miller, Michael; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Schmidt, Ianos; Akchurin, Nural; Carrell, Kenneth Wayne; Gusum, K; Kim, Heejong; Spezziga, Mario; Thomas, Ray; Wigmans, Richard; Baarmand, Marc M; Mermerkaya, Hamit; Ralich, Robert; Vodopiyanov, Igor; Kramer, Laird; Linn, Stephan; Markowitz, Pete; Cushman, Priscilla; Ma, Yousi; Sherwood, Brian; Cremaldi, Lucien Marcus; Reidy, Jim; Sanders, David A; Karmgard, Daniel John; Ruchti, Randy; Fisher, Wade Cameron; Tully, Christopher; Bodek, Arie; De Barbaro, Pawel; Budd, Howard; Chung, Yeon Sei; Haelen, T; Hagopian, Sharon; Hagopian, Vasken; Johnson, Kurtis F; Barnes, Virgil E; Laasanen, Alvin T

    2008-01-01

    Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\\% to 5\\%.

  1. Integration of the CMS Phase 1 Pixel Detector

    CERN Document Server

    Kornmayer, Andreas

    2018-01-01

    During the extended year-end technical stop 2016/17 the CMS Pixel Detector has been replaced. The new Phase 1 Pixel Detector is designed for a luminosity that could exceed $\\text{L} = 2x10^{34} cm^{−2}s^{−1}$. With one additional layer in the barrel and the forward region of the new detector, combined with the higher hit rates as the LHC luminosity increases, these conditions called for an upgrade of the data acquisition system, which was realised based on the $\\mu$TCA standard. This contribution focuses on the experiences with integration of the new detector readout and control system and reports on the operational performance of the CMS Pixel detector.

  2. Data concentrator card and test system for the CMS ECAL readout

    CERN Document Server

    Almeida, N; Alemany, R; Cardoso, N; Varela, J

    2003-01-01

    The Data Concentrator Card (DCC) is part of the Off-Detector (OD) Electronics sub-system of the CMS Electromagnetic Calorimeter. The DCC is responsible for crystal and trigger data collection from the Front-End system and from the ECAL Trigger system respectively.

  3. The CMS tracker calibration workflow: Experience with cosmic ray data

    International Nuclear Information System (INIS)

    Frosali, Simone

    2010-01-01

    During the second part of 2008 a CMS commissioning was performed with the acquisition of cosmic events in global runs. Cosmic rays detected in the muon chambers were used to trigger the readout of all CMS subdetectors in the general data acquisition system. A total of about 300M of tracks were collected by the CMS Muon Chambers with a 3.8T magnetic field produced by the CMS superconducting solenoid, 6M of which pointing to the tracker region and reconstructed by the Si-Strip Tracker (SST) detectors. Other 1M of cosmic tracks were collected with the magnetic field off. Using the cosmic data available it was possible to validate the performances of the CMS tracker calibration workflows. In this paper the adopted calibration workflow is described. In particular, the three main calibration workflows requested for the low level reconstruction of the SST, i.e. gain calibration, Lorentz angle calibration and bad components identification, are described. The results obtained using cosmic tracks for these three calibration workflows are also presented.

  4. Commissioning and Performance of the CMS Silicon Strip Tracker with Cosmic Ray Muons

    CERN Document Server

    Chatrchyan, S; Sirunyan, A M; Adam, W; Arnold, B; Bergauer, H; Bergauer, T; Dragicevic, M; Eichberger, M; Erö, J; Friedl, M; Frühwirth, R; Ghete, V M; Hammer, J; Hänsel, S; Hoch, M; Hörmann, N; Hrubec, J; Jeitler, M; Kasieczka, G; Kastner, K; Krammer, M; Liko, D; Magrans de Abril, I; Mikulec, I; Mittermayr, F; Neuherz, B; Oberegger, M; Padrta, M; Pernicka, M; Rohringer, H; Schmid, S; Schöfbeck, R; Schreiner, T; Stark, R; Steininger, H; Strauss, J; Taurok, A; Teischinger, F; Themel, T; Uhl, D; Wagner, P; Waltenberger, W; Walzel, G; Widl, E; Wulz, C E; Chekhovsky, V; Dvornikov, O; Emeliantchik, I; Litomin, A; Makarenko, V; Marfin, I; Mossolov, V; Shumeiko, N; Solin, A; Stefanovitch, R; Suarez Gonzalez, J; Tikhonov, A; Fedorov, A; Karneyeu, A; Korzhik, M; Panov, V; Zuyeuski, R; Kuchinsky, P; Beaumont, W; Benucci, L; Cardaci, M; De Wolf, E A; Delmeire, E; Druzhkin, D; Hashemi, M; Janssen, X; Maes, T; Mucibello, L; Ochesanu, S; Rougny, R; Selvaggi, M; Van Haevermaet, H; Van Mechelen, P; Van Remortel, N; Adler, V; Beauceron, S; Blyweert, S; D'Hondt, J; De Weirdt, S; Devroede, O; Heyninck, J; Kalogeropoulos, A; Maes, J; Maes, M; Mozer, M U; Tavernier, S; Van Doninck, W; Van Mulders, P; Villella, I; Bouhali, O; Chabert, E C; Charaf, O; Clerbaux, B; De Lentdecker, G; Dero, V; Elgammal, S; Gay, A P R; Hammad, G H; Marage, P E; Rugovac, S; Vander Velde, C; Vanlaer, P; Wickens, J; Grunewald, M; Klein, B; Marinov, A; Ryckbosch, D; Thyssen, F; Tytgat, M; Vanelderen, L; Verwilligen, P; Basegmez, S; Bruno, G; Caudron, J; Delaere, C; Demin, P; Favart, D; Giammanco, A; Grégoire, G; Lemaitre, V; Militaru, O; Ovyn, S; Piotrzkowski, K; Quertenmont, L; Schul, N; Beliy, N; Daubie, E; Alves, G A; Pol, M E; Souza, M H G; Carvalho, W; De Jesus Damiao, D; De Oliveira Martins, C; Fonseca De Souza, S; Mundim, L; Oguri, V; Santoro, A; Silva Do Amaral, S M; Sznajder, A; Fernandez Perez Tomei, T R; Ferreira Dias, M A; Gregores, E M; Novaes, S F; Abadjiev, K; Anguelov, T; Damgov, J; Darmenov, N; Dimitrov, L; Genchev, V; Iaydjiev, P; Piperov, S; Stoykova, S; Sultanov, G; Trayanov, R; Vankov, I; Dimitrov, A; Dyulendarova, M; Kozhuharov, V; Litov, L; Marinova, E; Mateev, M; Pavlov, B; Petkov, P; Toteva, Z; Chen, G M; Chen, H S; Guan, W; Jiang, C H; Liang, D; Liu, B; Meng, X; Tao, J; Wang, J; Wang, Z; Xue, Z; Zhang, Z; Ban, Y; Cai, J; Ge, Y; Guo, S; Hu, Z; Mao, Y; Qian, S J; Teng, H; Zhu, B; Avila, C; Baquero Ruiz, M; Carrillo Montoya, C A; Gomez, A; Gomez Moreno, B; Ocampo Rios, A A; Osorio Oliveros, A F; Reyes Romero, D; Sanabria, J C; Godinovic, N; Lelas, K; Plestina, R; Polic, D; Puljak, I; Antunovic, Z; Dzelalija, M; Brigljevic, V; Duric, S; Kadija, K; Morovic, S; Fereos, R; Galanti, M; Mousa, J; Papadakis, A; Ptochos, F; Razis, P A; Tsiakkouri, D; Zinonos, Z; Hektor, A; Kadastik, M; Kannike, K; Müntel, M; Raidal, M; Rebane, L; Anttila, E; Czellar, S; Härkönen, J; Heikkinen, A; Karimäki, V; Kinnunen, R; Klem, J; Kortelainen, M J; Lampén, T; Lassila-Perini, K; Lehti, S; Lindén, T; Luukka, P; Mäenpää, T; Nysten, J; Tuominen, E; Tuominiemi, J; Ungaro, D; Wendland, L; Banzuzi, K; Korpela, A; Tuuva, T; Nedelec, P; Sillou, D; Besancon, M; Chipaux, R; Dejardin, M; Denegri, D; Descamps, J; Fabbro, B; Faure, J L; Ferri, F; Ganjour, S; Gentit, F X; Givernaud, A; Gras, P; Hamel de Monchenault, G; Jarry, P; Lemaire, M C; Locci, E; Malcles, J; Marionneau, M; Millischer, L; Rander, J; Rosowsky, A; Rousseau, D; Titov, M; Verrecchia, P; Baffioni, S; Bianchini, L; Bluj, M; Busson, P; Charlot, C; Dobrzynski, L; Granier de Cassagnac, R; Haguenauer, M; Miné, P; Paganini, P; Sirois, Y; Thiebaux, C; Zabi, A; Agram, J L; Besson, A; Bloch, D; Bodin, D; Brom, J M; Conte, E; Drouhin, F; Fontaine, J C; Gelé, D; Goerlach, U; Gross, L; Juillot, P; Le Bihan, A C; Patois, Y; Speck, J; Van Hove, P; Baty, C; Bedjidian, M; Blaha, J; Boudoul, G; Brun, H; Chanon, N; Chierici, R; Contardo, D; Depasse, P; Dupasquier, T; El Mamouni, H; Fassi, F; Fay, J; Gascon, S; Ille, B; Kurca, T; Le Grand, T; Lethuillier, M; Lumb, N; Mirabito, L; Perries, S; Vander Donckt, M; Verdier, P; Djaoshvili, N; Roinishvili, N; Roinishvili, V; Amaglobeli, N; Adolphi, R; Anagnostou, G; Brauer, R; Braunschweig, W; Edelhoff, M; Esser, H; Feld, L; Karpinski, W; Khomich, A; Klein, K; Mohr, N; Ostaptchouk, A; Pandoulas, D; Pierschel, G; Raupach, F; Schael, S; Schultz von Dratzig, A; Schwering, G; Sprenger, D; Thomas, M; Weber, M; Wittmer, B; Wlochal, M; Actis, O; Altenhöfer, G; Bender, W; Biallass, P; Erdmann, M; Fetchenhauer, G; Frangenheim, J; Hebbeker, T; Hilgers, G; Hinzmann, A; Hoepfner, K; Hof, C; Kirsch, M; Klimkovich, T; Kreuzer, P; Lanske, D; Merschmeyer, M; Meyer, A; Philipps, B; Pieta, H; Reithler, H; Schmitz, S A; Sonnenschein, L; Sowa, M; Steggemann, J; Szczesny, H; Teyssier, D; Zeidler, C; Bontenackels, M; Davids, M; Duda, M; Flügge, G; Geenen, H; Giffels, M; Haj Ahmad, W; Hermanns, T; Heydhausen, D; Kalinin, S; Kress, T; Linn, A; Nowack, A; Perchalla, L; Poettgens, M; Pooth, O; Sauerland, P; Stahl, A; Tornier, D; Zoeller, M H; Aldaya Martin, M; Behrens, U; Borras, K; Campbell, A; Castro, E; Dammann, D; Eckerlin, G; Flossdorf, A; Flucke, G; Geiser, A; Hatton, D; Hauk, J; Jung, H; Kasemann, M; Katkov, I; Kleinwort, C; Kluge, H; Knutsson, A; Kuznetsova, E; Lange, W; Lohmann, W; Mankel, R; Marienfeld, M; Meyer, A B; Miglioranzi, S; Mnich, J; Ohlerich, M; Olzem, J; Parenti, A; Rosemann, C; Schmidt, R; Schoerner-Sadenius, T; Volyanskyy, D; Wissing, C; Zeuner, W D; Autermann, C; Bechtel, F; Draeger, J; Eckstein, D; Gebbert, U; Kaschube, K; Kaussen, G; Klanner, R; Mura, B; Naumann-Emme, S; Nowak, F; Pein, U; Sander, C; Schleper, P; Schum, T; Stadie, H; Steinbrück, G; Thomsen, J; Wolf, R; Bauer, J; Blüm, P; Buege, V; Cakir, A; Chwalek, T; De Boer, W; Dierlamm, A; Dirkes, G; Feindt, M; Felzmann, U; Frey, M; Furgeri, A; Gruschke, J; Hackstein, C; Hartmann, F; Heier, S; Heinrich, M; Held, H; Hirschbuehl, D; Hoffmann, K H; Honc, S; Jung, C; Kuhr, T; Liamsuwan, T; Martschei, D; Mueller, S; Müller, Th; Neuland, M B; Niegel, M; Oberst, O; Oehler, A; Ott, J; Peiffer, T; Piparo, D; Quast, G; Rabbertz, K; Ratnikov, F; Ratnikova, N; Renz, M; Saout, C; Sartisohn, G; Scheurer, A; Schieferdecker, P; Schilling, F P; Schott, G; Simonis, H J; Stober, F M; Sturm, P; Troendle, D; Trunov, A; Wagner, W; Wagner-Kuhr, J; Zeise, M; Zhukov, V; Ziebarth, E B; Daskalakis, G; Geralis, T; Karafasoulis, K; Kyriakis, A; Loukas, D; Markou, A; Markou, C; Mavrommatis, C; Petrakou, E; Zachariadou, A; Gouskos, L; Katsas, P; Panagiotou, A; Evangelou, I; Kokkas, P; Manthos, N; Papadopoulos, I; Patras, V; Triantis, F A; Bencze, G; Boldizsar, L; Debreczeni, G; Hajdu, C; Hernath, S; Hidas, P; Horvath, D; Krajczar, K; Laszlo, A; Patay, G; Sikler, F; Toth, N; Vesztergombi, G; Beni, N; Christian, G; Imrek, J; Molnar, J; Novak, D; Palinkas, J; Szekely, G; Szillasi, Z; Tokesi, K; Veszpremi, V; Kapusi, A; Marian, G; Raics, P; Szabo, Z; Trocsanyi, Z L; Ujvari, B; Zilizi, G; Bansal, S; Bawa, H S; Beri, S B; Bhatnagar, V; Jindal, M; Kaur, M; Kaur, R; Kohli, J M; Mehta, M Z; Nishu, N; Saini, L K; Sharma, A; Singh, A; Singh, J B; Singh, S P; Ahuja, S; Arora, S; Bhattacharya, S; Chauhan, S; Choudhary, B C; Gupta, P; Jain, S; Jha, M; Kumar, A; Ranjan, K; Shivpuri, R K; Srivastava, A K; Choudhury, R K; Dutta, D; Kailas, S; Kataria, S K; Mohanty, A K; Pant, L M; Shukla, P; Topkar, A; Aziz, T; Guchait, M; Gurtu, A; Maity, M; Majumder, D; Majumder, G; Mazumdar, K; Nayak, A; Saha, A; Sudhakar, K; Banerjee, S; Dugad, S; Mondal, N K; Arfaei, H; Bakhshiansohi, H; Fahim, A; Jafari, A; Mohammadi Najafabadi, M; Moshaii, A; Paktinat Mehdiabadi, S; Rouhani, S; Safarzadeh, B; Zeinali, M; Felcini, M; Abbrescia, M; Barbone, L; Chiumarulo, F; Clemente, A; Colaleo, A; Creanza, D; Cuscela, G; De Filippis, N; De Palma, M; De Robertis, G; Donvito, G; Fedele, F; Fiore, L; Franco, M; Iaselli, G; Lacalamita, N; Loddo, F; Lusito, L; Maggi, G; Maggi, M; Manna, N; Marangelli, B; My, S; Natali, S; Nuzzo, S; Papagni, G; Piccolomo, S; Pierro, G A; Pinto, C; Pompili, A; Pugliese, G; Rajan, R; Ranieri, A; Romano, F; Roselli, G; Selvaggi, G; Shinde, Y; Silvestris, L; Tupputi, S; Zito, G; Abbiendi, G; Bacchi, W; Benvenuti, A C; Boldini, M; Bonacorsi, D; Braibant-Giacomelli, S; Cafaro, V D; Caiazza, S S; Capiluppi, P; Castro, A; Cavallo, F R; Codispoti, G; Cuffiani, M; D'Antone, I; Dallavalle, G M; Fabbri, F; Fanfani, A; Fasanella, D; Giacomelli, P; Giordano, V; Giunta, M; Grandi, C; Guerzoni, M; Marcellini, S; Masetti, G; Montanari, A; Navarria, F L; Odorici, F; Pellegrini, G; Perrotta, A; Rossi, A M; Rovelli, T; Siroli, G; Torromeo, G; Travaglini, R; Albergo, S; Costa, S; Potenza, R; Tricomi, A; Tuve, C; Barbagli, G; Broccolo, G; Ciulli, V; Civinini, C; D'Alessandro, R; Focardi, E; Frosali, S; Gallo, E; Genta, C; Landi, G; Lenzi, P; Meschini, M; Paoletti, S; Sguazzoni, G; Tropiano, A; Benussi, L; Bertani, M; Bianco, S; Colafranceschi, S; Colonna, D; Fabbri, F; Giardoni, M; Passamonti, L; Piccolo, D; Pierluigi, D; Ponzio, B; Russo, A; Fabbricatore, P; Musenich, R; Benaglia, A; Calloni, M; Cerati, G B; D'Angelo, P; De Guio, F; Farina, F M; Ghezzi, A; Govoni, P; Malberti, M; Malvezzi, S; Martelli, A; Menasce, D; Miccio, V; Moroni, L; Negri, P; Paganoni, M; Pedrini, D; Pullia, A; Ragazzi, S; Redaelli, N; Sala, S; Salerno, R; Tabarelli de Fatis, T; Tancini, V; Taroni, S; Buontempo, S; Cavallo, N; Cimmino, A; De Gruttola, M; Fabozzi, F; Iorio, A O M; Lista, L; Lomidze, D; Noli, P; Paolucci, P; Sciacca, C; Azzi, P; Bacchetta, N; Barcellan, L; Bellan, P; Bellato, M; Benettoni, M; Biasotto, M; Bisello, D; Borsato, E; Branca, A; Carlin, R; Castellani, L; Checchia, P; Conti, E; Dal Corso, F; De Mattia, M; Dorigo, T; Dosselli, U; Fanzago, F; Gasparini, F; Gasparini, U; Giubilato, P; Gonella, F; Gresele, A; Gulmini, M; Kaminskiy, A; Lacaprara, S; Lazzizzera, I; Margoni, M; Maron, G; Mattiazzo, S; Mazzucato, M; Meneghelli, M; Meneguzzo, A T; Michelotto, M; Montecassiano, F; Nespolo, M; Passaseo, M; Pegoraro, M; Perrozzi, L; Pozzobon, N; Ronchese, P; Simonetto, F; Toniolo, N; Torassa, E; Tosi, M; Triossi, A; Vanini, S; Ventura, S; Zotto, P; Zumerle, G; Baesso, P; Berzano, U; Bricola, S; Necchi, M M; Pagano, D; Ratti, S P; Riccardi, C; Torre, P; Vicini, A; Vitulo, P; Viviani, C; Aisa, D; Aisa, S; Babucci, E; Biasini, M; Bilei, G M; Caponeri, B; Checcucci, B; Dinu, N; Fanò, L; Farnesini, L; Lariccia, P; Lucaroni, A; Mantovani, G; Nappi, A; Piluso, A; Postolache, V; Santocchia, A; Servoli, L; Tonoiu, D; Vedaee, A; Volpe, R; Azzurri, P; Bagliesi, G; Bernardini, J; Berretta, L; Boccali, T; Bocci, A; Borrello, L; Bosi, F; Calzolari, F; Castaldi, R; Dell'Orso, R; Fiori, F; Foà, L; Gennai, S; Giassi, A; Kraan, A; Ligabue, F; Lomtadze, T; Mariani, F; Martini, L; Massa, M; Messineo, A; Moggi, A; Palla, F; Palmonari, F; Petragnani, G; Petrucciani, G; Raffaelli, F; Sarkar, S; Segneri, G; Serban, A T; Spagnolo, P; Tenchini, R; Tolaini, S; Tonelli, G; Venturi, A; Verdini, P G; Baccaro, S; Barone, L; Bartoloni, A; Cavallari, F; Dafinei, I; Del Re, D; Di Marco, E; Diemoz, M; Franci, D; Longo, E; Organtini, G; Palma, A; Pandolfi, F; Paramatti, R; Pellegrino, F; Rahatlou, S; Rovelli, C; Alampi, G; Amapane, N; Arcidiacono, R; Argiro, S; Arneodo, M; Biino, C; Borgia, M A; Botta, C; Cartiglia, N; Castello, R; Cerminara, G; Costa, M; Dattola, D; Dellacasa, G; Demaria, N; Dughera, G; Dumitrache, F; Graziano, A; Mariotti, C; Marone, M; Maselli, S; Migliore, E; Mila, G; Monaco, V; Musich, M; Nervo, M; Obertino, M M; Oggero, S; Panero, R; Pastrone, N; Pelliccioni, M; Romero, A; Ruspa, M; Sacchi, R; Solano, A; Staiano, A; Trapani, P P; Trocino, D; Vilela Pereira, A; Visca, L; Zampieri, A; Ambroglini, F; Belforte, S; Cossutti, F; Della Ricca, G; Gobbo, B; Penzo, A; Chang, S; Chung, J; Kim, D H; Kim, G N; Kong, D J; Park, H; Son, D C; Bahk, S Y; Song, S; Jung, S Y; Hong, B; Kim, H; Kim, J H; Lee, K S; Moon, D H; Park, S K; Rhee, H B; Sim, K S; Kim, J; Choi, M; Hahn, G; Park, I C; Choi, S; Choi, Y; Goh, J; Jeong, H; Kim, T J; Lee, J; Lee, S; Janulis, M; Martisiute, D; Petrov, P; Sabonis, T; Castilla Valdez, H; Sánchez Hernández, A; Carrillo Moreno, S; Morelos Pineda, A; Allfrey, P; Gray, R N C; Krofcheck, D; Bernardino Rodrigues, N; Butler, P H; Signal, T; Williams, J C; Ahmad, M; Ahmed, I; Ahmed, W; Asghar, M I; Awan, M I M; Hoorani, H R; Hussain, I; Khan, W A; Khurshid, T; Muhammad, S; Qazi, S; Shahzad, H; Cwiok, M; Dabrowski, R; Dominik, W; Doroba, K; Konecki, M; Krolikowski, J; Pozniak, K; Romaniuk, Ryszard; Zabolotny, W; Zych, P; Frueboes, T; Gokieli, R; Goscilo, L; Górski, M; Kazana, M; Nawrocki, K; Szleper, M; Wrochna, G; Zalewski, P; Almeida, N; Antunes Pedro, L; Bargassa, P; David, A; Faccioli, P; Ferreira Parracho, P G; Freitas Ferreira, M; Gallinaro, M; Guerra Jordao, M; Martins, P; Mini, G; Musella, P; Pela, J; Raposo, L; Ribeiro, P Q; Sampaio, S; Seixas, J; Silva, J; Silva, P; Soares, D; Sousa, M; Varela, J; Wöhri, H K; Altsybeev, I; Belotelov, I; Bunin, P; Ershov, Y; Filozova, I; Finger, M; Finger, M., Jr.; Golunov, A; Golutvin, I; Gorbounov, N; Kalagin, V; Kamenev, A; Karjavin, V; Konoplyanikov, V; Korenkov, V; Kozlov, G; Kurenkov, A; Lanev, A; Makankin, A; Mitsyn, V V; Moisenz, P; Nikonov, E; Oleynik, D; Palichik, V; Perelygin, V; Petrosyan, A; Semenov, R; Shmatov, S; Smirnov, V; Smolin, D; Tikhonenko, E; Vasil'ev, S; Vishnevskiy, A; Volodko, A; Zarubin, A; Zhiltsov, V; Bondar, N; Chtchipounov, L; Denisov, A; Gavrikov, Y; Gavrilov, G; Golovtsov, V; Ivanov, Y; Kim, V; Kozlov, V; Levchenko, P; Obrant, G; Orishchin, E; Petrunin, A; Shcheglov, Y; Shchetkovskiy, A; Sknar, V; Smirnov, I; Sulimov, V; Tarakanov, V; Uvarov, L; Vavilov, S; Velichko, G; Volkov, S; Vorobyev, A; Andreev, Yu; Anisimov, A; Antipov, P; Dermenev, A; Gninenko, S; Golubev, N; Kirsanov, M; Krasnikov, N; Matveev, V; Pashenkov, A; Postoev, V E; Solovey, A; Toropin, A; Troitsky, S; Baud, A; Epshteyn, V; Gavrilov, V; Ilina, N; Kaftanov, V; Kolosov, V; Kossov, M; Krokhotin, A; Kuleshov, S; Oulianov, A; Safronov, G; Semenov, S; Shreyber, I; Stolin, V; Vlasov, E; Zhokin, A; Boos, E; Dubinin, M; Dudko, L; Ershov, A; Gribushin, A; Klyukhin, V; Kodolova, O; Lokhtin, I; Petrushanko, S; Sarycheva, L; Savrin, V; Snigirev, A; Vardanyan, I; Dremin, I; Kirakosyan, M; Konovalova, N; Rusakov, S V; Vinogradov, A; Akimenko, S; Artamonov, A; Azhgirey, I; Bitioukov, S; Burtovoy, V; Grishin, V; Kachanov, V; Konstantinov, D; Krychkine, V; Levine, A; Lobov, I; Lukanin, V; Mel'nik, Y; Petrov, V; Ryutin, R; Slabospitsky, S; Sobol, A; Sytine, A; Tourtchanovitch, L; Troshin, S; Tyurin, N; Uzunian, A; Volkov, A; Adzic, P; Djordjevic, M; Jovanovic, D; Krpic, D; Maletic, D; Puzovic, J; Smiljkovic, N; Aguilar-Benitez, M; Alberdi, J; Alcaraz Maestre, J; Arce, P; Barcala, J M; Battilana, C; Burgos Lazaro, C; Caballero Bejar, J; Calvo, E; Cardenas Montes, M; Cepeda, M; Cerrada, M; Chamizo Llatas, M; Clemente, F; Colino, N; Daniel, M; De La Cruz, B; Delgado Peris, A; Diez Pardos, C; Fernandez Bedoya, C; Fernández Ramos, J P; Ferrando, A; Flix, J; Fouz, M C; Garcia-Abia, P; Garcia-Bonilla, A C; Gonzalez Lopez, O; Goy Lopez, S; Hernandez, J M; Josa, M I; Marin, J; Merino, G; Molina, J; Molinero, A; Navarrete, J J; Oller, J C; Puerta Pelayo, J; Romero, L; Santaolalla, J; Villanueva Munoz, C; Willmott, C; Yuste, C; Albajar, C; Blanco Otano, M; de Trocóniz, J F; Garcia Raboso, A; Lopez Berengueres, J O; Cuevas, J; Fernandez Menendez, J; Gonzalez Caballero, I; Lloret Iglesias, L; Naves Sordo, H; Vizan Garcia, J M; Cabrillo, I J; Calderon, A; Chuang, S H; Diaz Merino, I; Diez Gonzalez, C; Duarte Campderros, J; Fernandez, M; Gomez, G; Gonzalez Sanchez, J; Gonzalez Suarez, R; Jorda, C; Lobelle Pardo, P; Lopez Virto, A; Marco, J; Marco, R; Martinez Rivero, C; Martinez Ruiz del Arbol, P; Matorras, F; Rodrigo, T; Ruiz Jimeno, A; Scodellaro, L; Sobron Sanudo, M; Vila, I; Vilar Cortabitarte, R; Abbaneo, D; Albert, E; Alidra, M; Ashby, S; Auffray, E; Baechler, J; Baillon, P; Ball, A H; Bally, S L; Barney, D; Beaudette, F; Bellan, R; Benedetti, D; Benelli, G; Bernet, C; Bloch, P; Bolognesi, S; Bona, M; Bos, J; Bourgeois, N; Bourrel, T; Breuker, H; Bunkowski, K; Campi, D; Camporesi, T; Cano, E; Cattai, A; Chatelain, J P; Chauvey, M; Christiansen, T; Coarasa Perez, J A; Conde Garcia, A; Covarelli, R; Curé, B; De Roeck, A; Delachenal, V; Deyrail, D; Di Vincenzo, S; Dos Santos, S; Dupont, T; Edera, L M; Elliott-Peisert, A; Eppard, M; Favre, M; Frank, N; Funk, W; Gaddi, A; Gastal, M; Gateau, M; Gerwig, H; Gigi, D; Gill, K; Giordano, D; Girod, J P; Glege, F; Gomez-Reino Garrido, R; Goudard, R; Gowdy, S; Guida, R; Guiducci, L; Gutleber, J; Hansen, M; Hartl, C; Harvey, J; Hegner, B; Hoffmann, H F; Holzner, A; Honma, A; Huhtinen, M; Innocente, V; Janot, P; Le Godec, G; Lecoq, P; Leonidopoulos, C; Loos, R; Lourenço, C; Lyonnet, A; Macpherson, A; Magini, N; Maillefaud, J D; Maire, G; Mäki, T; Malgeri, L; Mannelli, M; Masetti, L; Meijers, F; Meridiani, P; Mersi, S; Meschi, E; Meynet Cordonnier, A; Moser, R; Mulders, M; Mulon, J; Noy, M; Oh, A; Olesen, G; Onnela, A; Orimoto, T; Orsini, L; Perez, E; Perinic, G; Pernot, J F; Petagna, P; Petiot, P; Petrilli, A; Pfeiffer, A; Pierini, M; Pimiä, M; Pintus, R; Pirollet, B; Postema, H; Racz, A; Ravat, S; Rew, S B; Rodrigues Antunes, J; Rolandi, G.; Rovere, M; Ryjov, V; Sakulin, H; Samyn, D; Sauce, H; Schäfer, C; Schlatter, W D; Schröder, M; Schwick, C; Sciaba, A; Segoni, I; Sharma, A; Siegrist, N; Siegrist, P; Sinanis, N; Sobrier, T; Sphicas, P; Spiga, D; Spiropulu, M; Stöckli, F; Traczyk, P; Tropea, P; Troska, J; Tsirou, A; Veillet, L; Veres, G I; Voutilainen, M; Wertelaers, P; Zanetti, M; Bertl, W; Deiters, K; Erdmann, W; Gabathuler, K; Horisberger, R; Ingram, Q; Kaestli, H C; König, S; Kotlinski, D; Langenegger, U; Meier, F; Renker, D; Rohe, T; Sibille, J; Starodumov, A; Betev, B; Caminada, L; Chen, Z; Cittolin, S; Da Silva Di Calafiori, D R; Dambach, S; Dissertori, G; Dittmar, M; Eggel, C; Eugster, J; Faber, G; Freudenreich, K; Grab, C; Hervé, A; Hintz, W; Lecomte, P; Luckey, P D; Lustermann, W; Marchica, C; Milenovic, P; Moortgat, F; Nardulli, A; Nessi-Tedaldi, F; Pape, L; Pauss, F; Punz, T; Rizzi, A; Ronga, F J; Sala, L; Sanchez, A K; Sawley, M C; Sordini, V; Stieger, B; Tauscher, L; Thea, A; Theofilatos, K; Treille, D; Trüb, P; Weber, M; Wehrli, L; Weng, J; Zelepoukine, S; Amsler, C; Chiochia, V; De Visscher, S; Regenfus, C; Robmann, P; Rommerskirchen, T; Schmidt, A; Tsirigkas, D; Wilke, L; Chang, Y H; Chen, E A; Chen, W T; Go, A; Kuo, C M; Li, S W; Lin, W; Bartalini, P; Chang, P; Chao, Y; Chen, K F; Hou, W S; Hsiung, Y; Lei, Y J; Lin, S W; Lu, R S; Schümann, J; Shiu, J G; Tzeng, Y M; Ueno, K; Velikzhanin, Y; Wang, C C; Wang, M; Adiguzel, A; Ayhan, A; Azman Gokce, A; Bakirci, M N; Cerci, S; Dumanoglu, I; Eskut, E; Girgis, S; Gurpinar, E; Hos, I; Karaman, T; Kayis Topaksu, A; Kurt, P; Önengüt, G; Önengüt Gökbulut, G; Ozdemir, K; Ozturk, S; Polatöz, A; Sogut, K; Tali, B; Topakli, H; Uzun, D; Vergili, L N; Vergili, M; Akin, I V; Aliev, T; Bilmis, S; Deniz, M; Gamsizkan, H; Guler, A M; Öcalan, K; Serin, M; Sever, R; Surat, U E; Zeyrek, M; Deliomeroglu, M; Demir, D; Gülmez, E; Halu, A; Isildak, B; Kaya, M; Kaya, O; Ozkorucuklu, S; Sonmez, N; Levchuk, L; Lukyanenko, S; Soroka, D; Zub, S; Bostock, F; Brooke, J J; Cheng, T L; Cussans, D; Frazier, R; Goldstein, J; Grant, N; Hansen, M; Heath, G P; Heath, H F; Hill, C; Huckvale, B; Jackson, J; Mackay, C K; Metson, S; Newbold, D M; Nirunpong, K; Smith, V J; Velthuis, J; Walton, R; Bell, K W; Brew, C; Brown, R M; Camanzi, B; Cockerill, D J A; Coughlan, J A; Geddes, N I; Harder, K; Harper, S; Kennedy, B W; Murray, P; Shepherd-Themistocleous, C H; Tomalin, I R; Williams, J H; Womersley, W J; Worm, S D; Bainbridge, R; Ball, G; Ballin, J; Beuselinck, R; Buchmuller, O; Colling, D; Cripps, N; Davies, G; Della Negra, M; Foudas, C; Fulcher, J; Futyan, D; Hall, G; Hays, J; Iles, G; Karapostoli, G; MacEvoy, B C; Magnan, A M; Marrouche, J; Nash, J; Nikitenko, A; Papageorgiou, A; Pesaresi, M; Petridis, K; Pioppi, M; Raymond, D M; Rompotis, N; Rose, A; Ryan, M J; Seez, C; Sharp, P; Sidiropoulos, G; Stettler, M; Stoye, M; Takahashi, M; Tapper, A; Timlin, C; Tourneur, S; Vazquez Acosta, M; Virdee, T; Wakefield, S; Wardrope, D; Whyntie, T; Wingham, M; Cole, J E; Goitom, I; Hobson, P R; Khan, A; Kyberd, P; Leslie, D; Munro, C; Reid, I D; Siamitros, C; Taylor, R; Teodorescu, L; Yaselli, I; Bose, T; Carleton, M; Hazen, E; Heering, A H; Heister, A; John, J St; Lawson, P; Lazic, D; Osborne, D; Rohlf, J; Sulak, L; Wu, S; Andrea, J; Avetisyan, A; Bhattacharya, S; Chou, J P; Cutts, D; Esen, S; Kukartsev, G; Landsberg, G; Narain, M; Nguyen, D; Speer, T; Tsang, K V; Breedon, R; Calderon De La Barca Sanchez, M; Case, M; Cebra, D; Chertok, M; Conway, J; Cox, P T; Dolen, J; Erbacher, R; Friis, E; Ko, W; Kopecky, A; Lander, R; Lister, A; Liu, H; Maruyama, S; Miceli, T; Nikolic, M; Pellett, D; Robles, J; Searle, M; Smith, J; Squires, M; Stilley, J; Tripathi, M; Vasquez Sierra, R; Veelken, C; Andreev, V; Arisaka, K; Cline, D; Cousins, R; Erhan, S; Hauser, J; Ignatenko, M; Jarvis, C; Mumford, J; Plager, C; Rakness, G; Schlein, P; Tucker, J; Valuev, V; Wallny, R; Yang, X; Babb, J; Bose, M; Chandra, A; Clare, R; Ellison, J A; Gary, J W; Hanson, G; Jeng, G Y; Kao, S C; Liu, F; Liu, H; Luthra, A; Nguyen, H; Pasztor, G; Satpathy, A; Shen, B C; Stringer, R; Sturdy, J; Sytnik, V; Wilken, R; Wimpenny, S; Branson, J G; Dusinberre, E; Evans, D; Golf, F; Kelley, R; Lebourgeois, M; Letts, J; Lipeles, E; Mangano, B; Muelmenstaedt, J; Norman, M; Padhi, S; Petrucci, A; Pi, H; Pieri, M; Ranieri, R; Sani, M; Sharma, V; Simon, S; Würthwein, F; Yagil, A; Campagnari, C; D'Alfonso, M; Danielson, T; Garberson, J; Incandela, J; Justus, C; Kalavase, P; Koay, S A; Kovalskyi, D; Krutelyov, V; Lamb, J; Lowette, S; Pavlunin, V; Rebassoo, F; Ribnik, J; Richman, J; Rossin, R; Stuart, D; To, W; Vlimant, J R; Witherell, M; Apresyan, A; Bornheim, A; Bunn, J; Chiorboli, M; Gataullin, M; Kcira, D; Litvine, V; Ma, Y; Newman, H B; Rogan, C; Timciuc, V; Veverka, J; Wilkinson, R; Yang, Y; Zhang, L; Zhu, K; Zhu, R Y; Akgun, B; Carroll, R; Ferguson, T; Jang, D W; Jun, S Y; Paulini, M; Russ, J; Terentyev, N; Vogel, H; Vorobiev, I; Cumalat, J P; Dinardo, M E; Drell, B R; Ford, W T; Heyburn, B; Luiggi Lopez, E; Nauenberg, U; Stenson, K; Ulmer, K; Wagner, S R; Zang, S L; Agostino, L; Alexander, J; Blekman, F; Cassel, D; Chatterjee, A; Das, S; Gibbons, L K; Heltsley, B; Hopkins, W; Khukhunaishvili, A; Kreis, B; Kuznetsov, V; Patterson, J R; Puigh, D; Ryd, A; Shi, X; Stroiney, S; Sun, W; Teo, W D; Thom, J; Vaughan, J; Weng, Y; Wittich, P; Beetz, C P; Cirino, G; Sanzeni, C; Winn, D; Abdullin, S; Afaq, M A; Albrow, M; Ananthan, B; Apollinari, G; Atac, M; Badgett, W; Bagby, L; Bakken, J A; Baldin, B; Banerjee, S; Banicz, K; Bauerdick, L A T; Beretvas, A; Berryhill, J; Bhat, P C; Biery, K; Binkley, M; Bloch, I; Borcherding, F; Brett, A M; Burkett, K; Butler, J N; Chetluru, V; Cheung, H W K; Chlebana, F; Churin, I; Cihangir, S; Crawford, M; Dagenhart, W; Demarteau, M; Derylo, G; Dykstra, D; Eartly, D P; Elias, J E; Elvira, V D; Evans, D; Feng, L; Fischler, M; Fisk, I; Foulkes, S; Freeman, J; Gartung, P; Gottschalk, E; Grassi, T; Green, D; Guo, Y; Gutsche, O; Hahn, A; Hanlon, J; Harris, R M; Holzman, B; Howell, J; Hufnagel, D; James, E; Jensen, H; Johnson, M; Jones, C D; Joshi, U; Juska, E; Kaiser, J; Klima, B; Kossiakov, S; Kousouris, K; Kwan, S; Lei, C M; Limon, P; Lopez Perez, J A; Los, S; Lueking, L; Lukhanin, G; Lusin, S; Lykken, J; Maeshima, K; Marraffino, J M; Mason, D; McBride, P; Miao, T; Mishra, K; Moccia, S; Mommsen, R; Mrenna, S; Muhammad, A S; Newman-Holmes, C; Noeding, C; O'Dell, V; Prokofyev, O; Rivera, R; Rivetta, C H; Ronzhin, A; Rossman, P; Ryu, S; Sekhri, V; Sexton-Kennedy, E; Sfiligoi, I; Sharma, S; Shaw, T M; Shpakov, D; Skup, E; Smith, R P; Soha, A; Spalding, W J; Spiegel, L; Suzuki, I; Tan, P; Tanenbaum, W; Tkaczyk, S; Trentadue, R; Uplegger, L; Vaandering, E W; Vidal, R; Whitmore, J; Wicklund, E; Wu, W; Yarba, J; Yumiceva, F; Yun, J C; Acosta, D; Avery, P; Barashko, V; Bourilkov, D; Chen, M; Di Giovanni, G P; Dobur, D; Drozdetskiy, A; Field, R D; Fu, Y; Furic, I K; Gartner, J; Holmes, D; Kim, B; Klimenko, S; Konigsberg, J; Korytov, A; Kotov, K; Kropivnitskaya, A; Kypreos, T; Madorsky, A; Matchev, K; Mitselmakher, G; Pakhotin, Y; Piedra Gomez, J; Prescott, C; Rapsevicius, V; Remington, R; Schmitt, M; Scurlock, B; Wang, D; Yelton, J; Ceron, C; Gaultney, V; Kramer, L; Lebolo, L M; Linn, S; Markowitz, P; Martinez, G; Rodriguez, J L; Adams, T; Askew, A; Baer, H; Bertoldi, M; Chen, J; Dharmaratna, W G D; Gleyzer, S V; Haas, J; Hagopian, S; Hagopian, V; Jenkins, M; Johnson, K F; Prettner, E; Prosper, H; Sekmen, S; Baarmand, M M; Guragain, S; Hohlmann, M; Kalakhety, H; Mermerkaya, H; Ralich, R; Vodopiyanov, I; Abelev, B; Adams, M R; Anghel, I M; Apanasevich, L; Bazterra, V E; Betts, R R; Callner, J; Castro, M A; Cavanaugh, R; Dragoiu, C; Garcia-Solis, E J; Gerber, C E; Hofman, D J; Khalatian, S; Mironov, C; Shabalina, E; Smoron, A; Varelas, N; Akgun, U; Albayrak, E A; Ayan, A S; Bilki, B; Briggs, R; Cankocak, K; Chung, K; Clarida, W; Debbins, P; Duru, F; Ingram, F D; Lae, C K; McCliment, E; Merlo, J P; Mestvirishvili, A; Miller, M J; Moeller, A; Nachtman, J; Newsom, C R; Norbeck, E; Olson, J; Onel, Y; Ozok, F; Parsons, J; Schmidt, I; Sen, S; Wetzel, J; Yetkin, T; Yi, K; Barnett, B A; Blumenfeld, B; Bonato, A; Chien, C Y; Fehling, D; Giurgiu, G; Gritsan, A V; Guo, Z J; Maksimovic, P; Rappoccio, S; Swartz, M; Tran, N V; Zhang, Y; Baringer, P; Bean, A; Grachov, O; Murray, M; Radicci, V; Sanders, S; Wood, J S; Zhukova, V; Bandurin, D; Bolton, T; Kaadze, K; Liu, A; Maravin, Y; Onoprienko, D; Svintradze, I; Wan, Z; Gronberg, J; Hollar, J; Lange, D; Wright, D; Baden, D; Bard, R; Boutemeur, M; Eno, S C; Ferencek, D; Hadley, N J; Kellogg, R G; Kirn, M; Kunori, S; Rossato, K; Rumerio, P; Santanastasio, F; Skuja, A; Temple, J; Tonjes, M B; Tonwar, S C; Toole, T; Twedt, E; Alver, B; Bauer, G; Bendavid, J; Busza, W; Butz, E; Cali, I A; Chan, M; D'Enterria, D; Everaerts, P; Gomez Ceballos, G; Hahn, K A; Harris, P; Jaditz, S; Kim, Y; Klute, M; Lee, Y J; Li, W; Loizides, C; Ma, T; Miller, M; Nahn, S; Paus, C; Roland, C; Roland, G; Rudolph, M; Stephans, G; Sumorok, K; Sung, K; Vaurynovich, S; Wenger, E A; Wyslouch, B; Xie, S; Yilmaz, Y; Yoon, A S; Bailleux, D; Cooper, S I; Cushman, P; Dahmes, B; De Benedetti, A; Dolgopolov, A; Dudero, P R; Egeland, R; Franzoni, G; Haupt, J; Inyakin, A; Klapoetke, K; Kubota, Y; Mans, J; Mirman, N; Petyt, D; Rekovic, V; Rusack, R; Schroeder, M; Singovsky, A; Zhang, J; Cremaldi, L M; Godang, R; Kroeger, R; Perera, L; Rahmat, R; Sanders, D A; Sonnek, P; Summers, D; Bloom, K; Bockelman, B; Bose, S; Butt, J; Claes, D R; Dominguez, A; Eads, M; Keller, J; Kelly, T; Kravchenko, I; Lazo-Flores, J; Lundstedt, C; Malbouisson, H; Malik, S; Snow, G R; Baur, U; Iashvili, I; Kharchilava, A; Kumar, A; Smith, K; Strang, M; Alverson, G; Barberis, E; Boeriu, O; Eulisse, G; Govi, G; McCauley, T; Musienko, Y; Muzaffar, S; Osborne, I; Paul, T; Reucroft, S; Swain, J; Taylor, L; Tuura, L; Anastassov, A; Gobbi, B; Kubik, A; Ofierzynski, R A; Pozdnyakov, A; Schmitt, M; Stoynev, S; Velasco, M; Won, S; Antonelli, L; Berry, D; Hildreth, M; Jessop, C; Karmgard, D J; Kolberg, T; Lannon, K; Lynch, S; Marinelli, N; Morse, D M; Ruchti, R; Slaunwhite, J; Warchol, J; Wayne, M; Bylsma, B; Durkin, L S; Gilmore, J; Gu, J; Killewald, P; Ling, T Y; Williams, G; Adam, N; Berry, E; Elmer, P; Garmash, A; Gerbaudo, D; Halyo, V; Hunt, A; Jones, J; Laird, E; Marlow, D; Medvedeva, T; Mooney, M; Olsen, J; Piroué, P; Stickland, D; Tully, C; Werner, J S; Wildish, T; Xie, Z; Zuranski, A; Acosta, J G; Bonnett Del Alamo, M; Huang, X T; Lopez, A; Mendez, H; Oliveros, S; Ramirez Vargas, J E; Santacruz, N; Zatzerklyany, A; Alagoz, E; Antillon, E; Barnes, V E; Bolla, G; Bortoletto, D; Everett, A; Garfinkel, A F; Gecse, Z; Gutay, L; Ippolito, N; Jones, M; Koybasi, O; Laasanen, A T; Leonardo, N; Liu, C; Maroussov, V; Merkel, P; Miller, D H; Neumeister, N; Sedov, A; Shipsey, I; Yoo, H D; Zheng, Y; Jindal, P; Parashar, N; Cuplov, V; Ecklund, K M; Geurts, F J M; Liu, J H; Maronde, D; Matveev, M; Padley, B P; Redjimi, R; Roberts, J; Sabbatini, L; Tumanov, A; Betchart, B; Bodek, A; Budd, H; Chung, Y S; de Barbaro, P; Demina, R; Flacher, H; Gotra, Y; Harel, A; Korjenevski, S; Miner, D C; Orbaker, D; Petrillo, G; Vishnevskiy, D; Zielinski, M; Bhatti, A; Demortier, L; Goulianos, K; Hatakeyama, K; Lungu, G; Mesropian, C; Yan, M; Atramentov, O; Bartz, E; Gershtein, Y; Halkiadakis, E; Hits, D; Lath, A; Rose, K; Schnetzer, S; Somalwar, S; Stone, R; Thomas, S; Watts, T L; Cerizza, G; Hollingsworth, M; Spanier, S; Yang, Z C; York, A; Asaadi, J; Aurisano, A; Eusebi, R; Golyash, A; Gurrola, A; Kamon, T; Nguyen, C N; Pivarski, J; Safonov, A; Sengupta, S; Toback, D; Weinberger, M; Akchurin, N; Berntzon, L; Gumus, K; Jeong, C; Kim, H; Lee, S W; Popescu, S; Roh, Y; Sill, A; Volobouev, I; Washington, E; Wigmans, R; Yazgan, E; Engh, D; Florez, C; Johns, W; Pathak, S; Sheldon, P; Andelin, D; Arenton, M W; Balazs, M; Boutle, S; Buehler, M; Conetti, S; Cox, B; Hirosky, R; Ledovskoy, A; Neu, C; Phillips II, D; Ronquest, M; Yohay, R; Gollapinni, S; Gunthoti, K; Harr, R; Karchin, P E; Mattson, M; Sakharov, A; Anderson, M; Bachtis, M; Bellinger, J N; Carlsmith, D; Crotty, I; Dasu, S; Dutta, S; Efron, J; Feyzi, F; Flood, K; Gray, L; Grogg, K S; Grothe, M; Hall-Wilton, R; Jaworski, M; Klabbers, P; Klukas, J; Lanaro, A; Lazaridis, C; Leonard, J; Loveless, R; Magrans de Abril, M; Mohapatra, A; Ott, G; Polese, G; Reeder, D; Savin, A; Smith, W H; Sourkov, A; Swanson, J; Weinberg, M; Wenman, D; Wensveen, M; White, A

    2010-01-01

    During autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the muon chambers and used to trigger the readout of all CMS sub-detectors. About 15 million events with a muon in the tracker were collected. The efficiency of hit and track reconstruction were measured to be higher than 99% and consistent with expectations from Monte Carlo simulation. This article details the commissioning and performance of the Silicon Strip Tracker with cosmic ray muons.

  5. the CMS Experiment at the HL-LHC

    Directory of Open Access Journals (Sweden)

    Pozzobon Nicola

    2016-01-01

    Full Text Available A major upgrade of the readout and trigger electronics of the CMS Drift Tubes muon detector is foreseen in order to allow its efficient operation at the High Luminosity LHC. A proposal for a new L1 Trigger Primitives Generator for this detector is presented, featuring an algorithm operating on the time of charge collection measurements provided by the asynchronous readout of the new TDC system being developed. The algorithm is being designed around the implementation in state-of-the-art FPGA devices of the original development of a Compact Hough Transform (CHT algorithm combined with a Majority Mean-Timer, to identify both the parent bunch crossing and the muon track parameters. The current state of the design is presented along with the performance requirements, focusing on the future developments.

  6. Position dependence of charge collection in prototype sensors for the CMS pixel detector

    CERN Document Server

    Rohe, Tilman; Chiochia, Vincenzo; Cremaldi, Lucien M; Cucciarelli, Susanna; Dorokhov, Andrei; Konecki, Marcin; Prokofiev, Kirill; Regenfus, Christian; Sanders, David A; Son Seung Hee; Speer, Thomas; Swartz, Morris

    2004-01-01

    This paper reports on the sensor R&D activity for the CMS pixel detector. Devices featuring several design and technology options have been irradiated up to a proton fluence1 of 1 multiplied by 10**1**5 n //e//q/cm**2 at the CERN PS. Afterward, they were bump bonded to unirradiated readout chips and tested using high energy pions in the H2 beam line of the CERN SPS. The readout chip allows a nonzero suppressed full analogue readout and therefore a good characterization of the sensors in terms of noise and charge collection properties. The position dependence of signal is presented and the differences between the two sensor options are discussed. 20 Refs.

  7. TRIGGER

    CERN Multimedia

    Wesley Smith

    Level-1 Trigger Hardware and Software The production of the trigger hardware is now basically finished, and in time for the turn-on of the LHC. The last boards produced are the Trigger Concentrator Cards for the ECAL Endcaps (TCC-EE). After the recent installation of the four EE Dees, the TCC-EE prototypes were used for their commissioning. Production boards are arriving and are being tested continuously, with the last ones expected in November. The Regional Calorimeter Trigger hardware is fully integrated after installation of the last EE cables. Pattern tests from the HCAL up to the GCT have been performed successfully. The HCAL triggers are fully operational, including the connection of the HCAL-outer and forward-HCAL (HO/HF) technical triggers to the Global Trigger. The HCAL Trigger and Readout (HTR) board firmware has been updated to permit recording of the tower “feature bit” in the data. The Global Calorimeter Trigger hardware is installed, but some firmware developments are still n...

  8. Design, Performance, and Calibration of the CMS Hadron-Outer Calorimeter

    CERN Document Server

    Abdullin, Salavat; Acharya, Bannaje Sripathi; Adam, Nadia; Adams, Mark Raymond; Akchurin, Nural; Akgun, Ugur; Albayrak, Elif Asli; Anderson, E Walter; Antchev, Georgy; Arcidy, M; Ayan, S; Aydin, Sezgin; Aziz, Tariq; Baarmand, Marc M; Babich, Kanstantsin; Baden, Drew; Bakirci, Mustafa Numan; Banerjee, Sunanda; Banerjee, Sudeshna; Bard, Robert; Barnes, Virgil E; Bawa, Harinder Singh; Baiatian, G; Bencze, Gyorgy; Beri, Suman Bala; Berntzon, Lisa; Bhatnagar, Vipin; Bhatti, Anwar; Bodek, Arie; Bose, Suvadeep; Bose, Tulika; Budd, Howard; Burchesky, Kyle; Camporesi, Tiziano; Cankocak, Kerem; Carrell, Kenneth Wayne; Cerci, Salim; Chendvankar, Sanjay; Chung, Yeon Sei; Clarida, Warren; Cremaldi, Lucien Marcus; Cushman, Priscilla; Damgov, Jordan; De Barbaro, Pawel; Debbins, Paul; Deliomeroglu, Mehmet; Demianov, A; de Visser, Theo; Deshpande, Pandurang Vishnu; Díaz, Jonathan; Dimitrov, Lubomir; Dugad, Shashikant; Dumanoglu, Isa; Duru, Firdevs; Efthymiopoulos, I; Elias, John E; Elvira, D; Emeliantchik, Igor; Eno, Sarah Catherine; Ershov, Alexander; Erturk, Sefa; Esen, Selda; Eskut, Eda; Fenyvesi, Andras; Fisher, Wade Cameron; Freeman, Jim; Ganguli, Som N; Gaultney, Vanessa; Gamsizkan, Halil; Gavrilov, Vladimir; Genchev, Vladimir; Gleyzer, Sergei V; Golutvin, Igor; Goncharov, Petr; Grassi, Tullio; Green, Dan; Gribushin, Andrey; Grinev, B; Gurtu, Atul; Murat Güler, A; Gülmez, Erhan; Gümüs, K; Haelen, T; Hagopian, Sharon; Hagopian, Vasken; Halyo, Valerie; Hashemi, Majid; Hauptman, John M; Hazen, Eric; Heering, Arjan Hendrix; Heister, Arno; Hunt, Adam; Ilyina, N; Ingram, D; Isiksal, Engin; Jarvis, Chad; Jeong, Chiyoung; Johnson, Kurtis F; Jones, John; Kaftanov, Vitali; Kalagin, Vladimir; Kalinin, Alexey; Kalmani, Suresh Devendrappa; Karmgard, Daniel John; Kaur, Manjit; Kaya, Mithat; Kaya, Ozlem; Kayis-Topaksu, A; Kellogg, Richard G; Khmelnikov, Alexander; Kim, Heejong; Kisselevich, I; Kodolova, Olga; Kohli, Jatinder Mohan; Kolossov, V; Korablev, Andrey; Korneev, Yury; Kosarev, Ivan; Kramer, Laird; Krinitsyn, Alexander; Krishnaswamy, Marthi Ramaswamy; Krokhotin, Andrey; Kryshkin, V; Kuleshov, Sergey; Kumar, Arun; Kunori, Shuichi; Laasanen, Alvin T; Ladygin, Vladimir; Laird, Edward; Landsberg, Greg; Laszlo, Andras; Lawlor, C; Lazic, Dragoslav; Lee, Sang Joon; Levchuk, Leonid; Linn, Stephan; Litvintsev, Dmitri; Lobolo, L; Los, Serguei; Lubinsky, V; Lukanin, Vladimir; Ma, Yousi; Machado, Emanuel; Maity, Manas; Majumder, Gobinda; Mans, Jeremy; Marlow, Daniel; Markowitz, Pete; Martínez, German; Mazumdar, Kajari; Merlo, Jean-Pierre; Mermerkaya, Hamit; Mescheryakov, G; Mestvirishvili, Alexi; Miller, Michael; Möller, A; Mohammadi-Najafabadi, M; Moissenz, P; Mondal, Naba Kumar; Mossolov, Vladimir; Nagaraj, P; Narasimham, Vemuri Syamala; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Onengüt, G; Ozkan, Cigdem; Ozkurt, Halil; Ozkorucuklu, Suat; Ozok, Ferhat; Paktinat, S; Pal, Andras; Patil, Mandakini Ravindra; Penzo, Aldo; Petrushanko, Sergey; Petrosian, A; Pikalov, Vladimir; Piperov, Stefan; Podrasky, V; Polatoz, A; Pompos, Arnold; Popescu, Sorina; Posch, C; Pozdnyakov, Andrey; Qian, Weiming; Ralich, Robert; Reddy, L; Reidy, Jim; Rogalev, Evgueni; Roh, Youn; Rohlf, James; Ronzhin, Anatoly; Ruchti, Randy; Ryazanov, Anton; Safronov, Grigory; Sanders, David A; Sanzeni, Christopher; Sarycheva, Ludmila; Satyanarayana, B; Schmidt, Ianos; Sekmen, Sezen; Semenov, Sergey; Senchishin, V; Sergeyev, S; Serin, Meltem; Sever, Ramazan; Singh, B; Singh, Jas Bir; Sirunyan, Albert M; Skuja, Andris; Sharma, Seema; Sherwood, Brian; Shumeiko, Nikolai; Smirnov, Vitaly; Sogut, Kenan; Sonmez, Nasuf; Sorokin, Pavel; Spezziga, Mario; Stefanovich, R; Stolin, Viatcheslav; Sudhakar, Katta; Sulak, Lawrence; Suzuki, Ichiro; Talov, Vladimir; Teplov, Konstantin; Thomas, Ray; Tonwar, Suresh C; Topakli, Huseyin; Tully, Christopher; Turchanovich, L; Ulyanov, A; Vanini, A; Vankov, Ivan; Vardanyan, Irina; Varela, F; Vergili, Mehmet; Verma, Piyush; Vesztergombi, Gyorgy; Vidal, Richard; Vishnevskiy, Alexander; Vlassov, E; Vodopiyanov, Igor; Volobouev, Igor; Volkov, Alexey; Volodko, Anton; Wang, Lei; Werner, Jeremy Scott; Wetstein, Matthew; Winn, Dave; Wigmans, Richard; Whitmore, Juliana; Wu, Shouxiang; Yazgan, Efe; Yetkin, Taylan; Zálán, Peter; Zarubin, Anatoli; Zeyrek, Mehmet

    2008-01-01

    The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with an outer calorimeter to ensure high energy shower containment in the calorimeter. Fabrication, testing and calibration of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing $\\et$ measurements at LHC energies. The outer hadron calorimeter will also be used for the muon trigger in coincidence with other muon chambers in CMS.

  9. System tests with silicon strip module prototypes for the Phase-2-upgrade of the CMS tracker

    Energy Technology Data Exchange (ETDEWEB)

    Feld, Lutz; Karpinski, Waclaw; Klein, Katja; Preuten, Marius [I. Physikalisches Institut B, RWTH Aachen University (Germany)

    2016-07-01

    To prepare the CMS experiment for the High Luminosity LHC and its instantaneous luminosity of 5 . 10{sup 34} cm{sup -2}s{sup -1}, in the Long Shutdown 3 (around 2024) the CMS Silicon Tracker will be replaced. The Silicon Strip Modules for the new Tracker will host two vertically stacked sensors. The combination of hit information from both sensors will allow the estimation of the transverse momentum (p{sub T}) of charged particles in the module front-end. This can be used to identify hits from potential interesting high-p{sub T} tracks (above 2 GeV) for the first trigger level. The CMS Binary Chip (CBC) provides the analogue readout of two sensors and a digital section, into which the momentum discrimination is integrated. The modules will host a new DC-DC converter chain, which will allow individual powering of each module. First measurements with early prototypes on the interplay between DC-DC powering and the read-out functions of the module are presented in this talk.

  10. Implementation of on-line data reduction algorithms in the CMS Endcap Preshower Data Concentrator Cards

    CERN Document Server

    Barney, D; Kokkas, P; Manthos, N; Sidiropoulos, G; Reynaud, S; Vichoudis, P

    2007-01-01

    The CMS Endcap Preshower (ES) sub-detector comprises 4288 silicon sensors, each containing 32 strips. The data are transferred from the detector to the counting room via 1208 optical fibres running at 800Mbps. Each fibre carries data from two, three or four sensors. For the readout of the Preshower, a VME-based system, the Endcap Preshower Data Concentrator Card (ES-DCC), is currently under development. The main objective of each readout board is to acquire on-detector data from up to 36 optical links, perform on-line data reduction via zero suppression and pass the concentrated data to the CMS event builder. This document presents the conceptual design of the Reduction Algorithms as well as their implementation in the ES-DCC FPGAs. These algorithms, as implemented in the ES-DCC, result in a data-reduction factor of 20.

  11. Implementation of On-Line Data Reduction Algorithms in the CMS Endcap Preshower Data Concentrator Card

    CERN Document Server

    Barney, David; Kokkas, Panagiotis; Manthos, Nikolaos; Reynaud, Serge; Sidiropoulos, Georgios; Vichoudis, Paschalis

    2006-01-01

    The CMS Endcap Preshower (ES) sub-detector comprises 4288 silicon sensors, each containing 32 strips. The data are transferred from the detector to the counting room via 1208 optical fibres running at 800Mbps. Each fibre carries data from 2, 3 or 4 sensors. For the readout of the Preshower, a VME-based system - the Endcap Preshower Data Concentrator Card (ES-DCC) is currently under development. The main objective of each readout board is to acquire on-detector data from up to 36 optical links, perform on-line data reduction (zero suppression) and pass the concentrated data to the CMS event builder. This document presents the conceptual design of the Reduction Algorithms as well as their implementation into the ES-DCC FPGAs. The algorithms implemented into the ES-DCC resulted in a reduction factor of ~20.

  12. Tracking in the trigger from the CDF experience to CMS upgrade

    CERN Document Server

    Palla, F

    2007-01-01

    Precise tracking information in the online selection of interesting physics events is extremely beneficial at hadron colliders. The CDF experiment at the Tevatron, has shown for the first time the impact of the tracking in triggers, allowing to achieve unprecedented precision in B-physics measurements. The CMS experiment at LHC will largely make use of tracking information at high level trigger, after the Level-1 acceptance. The increased luminosity of the Super-LHC collider will impose to CMS a drastic revision of the Level-1 trigger strategy, incorporating the tracker information at the first stage of the selection. After a review of the CDF and CMS approaches we will discuss several possible Level-1 tracker based concepts for the upgraded CMS detector at Super-LHC. One approach is based on associative memories, which has already been demonstrated in CDF. It makes use of binary readout in the front end electronics, followed by transfer of the full granularity data off detector using optical links to dedicat...

  13. Module Production and Qualification for the Phase I Upgrade of the CMS Pixel Detector

    CERN Document Server

    AUTHOR|(CDS)2086689

    2015-01-01

    After consolidation of the LHC in 2013/14 its centre-of-mass energy will increase to 13TeV and the luminosity will reach $2 \\cdot 10^{34}\\, \\textnormal{cm}^{-2} \\textnormal{s}^{-1}$, which is twice the design luminosity. The latter will result in more simultaneous particle collisions, which would significantly increase the dead time of the current readout chip of the CMS pixel detector. Therefore the entire CMS pixel detector is replaced in 2016/17 and a new digital readout with larger buffers will be used to handle increasing pixel hit rates. An additional fourth barrel-layer provides more space points to improve track reconstruction. Half of the required modules for layer four is being produced at Karlsruhe Institute of Technology (KIT). This poster deals with the smallest discrete subunit of the pixel detector, the module and its assembly process. Moreover first production experience will be shown.

  14. Laser Transmitters for the optical link systems used in CMS

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    In the CMS experiment of the now new flagship LHC optical links will be used for the tracker readout system. One part of this components will be semiconductor laser (~50.000 !!!), named correctly: 1310 nm InGaAsP (DCPBH-MQW) edge-emitting laser. They are foreseen as transmitter in the Tx Hybrid part of the optical link system.

  15. Saturation and Energy Corrections for TeV Electrons and Photons

    CERN Document Server

    Clerbaux, Barbara; Mahmoud, Tariq; Marage, Pierre Edouard

    2006-01-01

    This note presents a study of the response of the CMS electromagnetic calorimeter ECAL to high energy electrons and photons (from 500 to 4000 GeV), using the full simulation of the CMS detector. The longitudinal containment and the lateral extension of high energy showers are discussed, and energy and eta dependent correction factors F(E_meas, eta), where E_meas = E_ECAL + E_HCAL, are determined in order to reconstruct the incident particle energy, using the energies measured in the ECAL and in the hadronic calorimeter HCAL. For ECAL barrel crystals with energy deposit higher than 1700 GeV, improvements are proposed to techniques aimed at correcting for the effects of electronics saturation.

  16. The construction of the phase 1 upgrade of the CMS pixel detector

    CERN Document Server

    Weber, Hannsjorg Artur

    2017-01-01

    The innermost layers of the original CMS tracker were built out of pixel detectors arranged in three barrel layers and two forward disks in each endcap. The original CMS detector was designed for the nominal instantaneous LHC luminosity of $1\\times10^{34}\\,\\text{cm}^{-2}\\text{s}^{-1}$. Under the conditions expected in the coming years, which will see an increase of a factor two of the instantaneous luminosity, the CMS pixel detector would have seen a dynamic inefficiency caused by data losses due to buffer overflows. For this reason the CMS collaboration has installed during the recent extended end of year shutdown a replacement pixel detector. The phase-1 upgrade of the CMS pixel detector will operate at high efficiency at an instantaneous luminosity of $2\\times10^{34}\\,\\text{cm}^{-2}\\text{s}^{-1}$ with increased detector acceptance and additional redundancy for the tracking, while at the same time reducing the material budget. These goals are achieved using a new read-out chip and modified powering and rea...

  17. Study of the CMS Phase 1 Pixel Pilot Blade Reconstruction

    CERN Document Server

    CMS Collaboration

    2017-01-01

    The silicon pixel detector is the innermost component of the CMS tracking system. It was replaced in March 2017 with an upgraded one, called the Phase 1 upgrade detector. During Long Shutdown 1, a third disk was inserted into the present forward pixel detector with eight prototype blades constructed using a new digital read-out chip architecture and a prototype readout chain. Testing the performance of these pilot modules enabled us to gain experience with the Phase 1 upgrade modules. In this document, the data reconstruction with the pilot system is presented. The hit finding efficiency and residual of these new modules is also shown, and how these observables were used to adjust the timing of the pilot blades.

  18. Single event upset studies on the CMS tracker APV25 readout chip

    International Nuclear Information System (INIS)

    Noah, E.; Bauer, T.; Bisello, D.; Faccio, F.; Friedl, M.; Fulcher, J.R.; Hall, G.; Huhtinen, M.; Kaminsky, A.; Pernicka, M.; Raymond, M.; Wyss, J.

    2002-01-01

    The microstrip tracker for the CMS experiment at the CERN Large Hadron Collider will be read out using APV25 chips. During high luminosity running the tracker will be exposed to particle fluxes up to 10 7 cm -2 s -1 , which raises concerns that the APV25 could occasionally suffer Single Event Upsets (SEUs). The effect of SEU on the APV25 has been studied to investigate implications for CMS detector operation and from the viewpoint of detailed circuit operation, to improve the understanding of its origin and what factors affect its magnitude. Simulations were performed to reconstruct the effects created by highly ionising particles striking sensitive parts of the circuits, along with consideration of the underlying mechanisms of charge deposition, collection and the consequences. A model to predict the behaviour of the memory circuits in the APV25 has been developed and data collected from dedicated experiments using both heavy ions and hadrons have been shown to support it

  19. Electronics for the CMS muon drift tube chambers the read-out minicrate

    CERN Document Server

    Fernandez Bedoya, Cristina; Oller, Juan Carlos; Willmott, Carlos

    2005-01-01

    On the Compact Muon Solenoid (CMS) experimentat the Large Hadron Collider (LHC) at the CERN laboratory, the drift tube chambers are responsible for muon detection and precise momentum measurement. In this paper the first level of the read out electronics for these drift tube chambers is described. These drift tube chambers will be located inside the muon barrel detector in the so-called minicrates (MCs), attached to the chambers. The read out boards (ROBs) are the main component of this first level data acquisition system, and they are responsible for the time digitalization related to Level 1 Accept (L1A) trigger of the incoming signals from the front-end electronics, followed by a consequent data merging to the next stages of the data acquisition system. ROBs' architecture and functionality have been exhaustively tested, as well as their capability of operation beyond the expected environmental conditions inside the CMS detector. Due to the satisfactory results obtained, final production of ROBs and their a...

  20. The CMS High-Level Trigger

    International Nuclear Information System (INIS)

    Covarelli, R.

    2009-01-01

    At the startup of the LHC, the CMS data acquisition is expected to be able to sustain an event readout rate of up to 100 kHz from the Level-1 trigger. These events will be read into a large processor farm which will run the 'High-Level Trigger'(HLT) selection algorithms and will output a rate of about 150 Hz for permanent data storage. In this report HLT performances are shown for selections based on muons, electrons, photons, jets, missing transverse energy, τ leptons and b quarks: expected efficiencies, background rates and CPU time consumption are reported as well as relaxation criteria foreseen for a LHC startup instantaneous luminosity.

  1. The CMS High-Level Trigger

    CERN Document Server

    Covarelli, Roberto

    2009-01-01

    At the startup of the LHC, the CMS data acquisition is expected to be able to sustain an event readout rate of up to 100 kHz from the Level-1 trigger. These events will be read into a large processor farm which will run the "High-Level Trigger" (HLT) selection algorithms and will output a rate of about 150 Hz for permanent data storage. In this report HLT performances are shown for selections based on muons, electrons, photons, jets, missing transverse energy, tau leptons and b quarks: expected efficiencies, background rates and CPU time consumption are reported as well as relaxation criteria foreseen for a LHC startup instantaneous luminosity.

  2. The CMS High-Level Trigger

    Science.gov (United States)

    Covarelli, R.

    2009-12-01

    At the startup of the LHC, the CMS data acquisition is expected to be able to sustain an event readout rate of up to 100 kHz from the Level-1 trigger. These events will be read into a large processor farm which will run the "High-Level Trigger" (HLT) selection algorithms and will output a rate of about 150 Hz for permanent data storage. In this report HLT performances are shown for selections based on muons, electrons, photons, jets, missing transverse energy, τ leptons and b quarks: expected efficiencies, background rates and CPU time consumption are reported as well as relaxation criteria foreseen for a LHC startup instantaneous luminosity.

  3. Fast beam conditions monitor BCM1F for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bell, A. [CERN, Geneva (Switzerland); Geneva Univ. (Switzerland); Castro, E. [DESY Zeuthen (Germany); Hall-Wilton, R. [CERN, Geneva (Switzerland); Wisconsin Univ., Madison, WI (US)] (and others)

    2009-10-15

    The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of different sub-systems measuring either the particle flux near the beam pipe with time resolution between nano- and microseconds or the integrated dose over longer time intervals. This paper presents the Fast Beam Conditions Monitor, BCM1F, which is designed for fast flux monitoring measuring both beam halo and collision products. BCM1F is located inside the CMS pixel detector volume close to the beam-pipe. It uses sCVD diamond sensors and radiation hard front-end electronics, along with an analog optical readout of the signals. The commissioning of the system and its successful operation during the first beams of the LHC are described. (orig.)

  4. Fast beam conditions monitor BCM1F for the CMS experiment

    International Nuclear Information System (INIS)

    Bell, A.; Castro, E.; Hall-Wilton, R.

    2009-10-01

    The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of different sub-systems measuring either the particle flux near the beam pipe with time resolution between nano- and microseconds or the integrated dose over longer time intervals. This paper presents the Fast Beam Conditions Monitor, BCM1F, which is designed for fast flux monitoring measuring both beam halo and collision products. BCM1F is located inside the CMS pixel detector volume close to the beam-pipe. It uses sCVD diamond sensors and radiation hard front-end electronics, along with an analog optical readout of the signals. The commissioning of the system and its successful operation during the first beams of the LHC are described. (orig.)

  5. The CMS silicon tracker

    International Nuclear Information System (INIS)

    Focardi, E.; Albergo, S.; Angarano, M.; Azzi, P.; Babucci, E.; Bacchetta, N.; Bader, A.; Bagliesi, G.; Basti, A.; Biggeri, U.; Bilei, G.M.; Bisello, D.; Boemi, D.; Bosi, F.; Borrello, L.; Bozzi, C.; Braibant, S.; Breuker, H.; Bruzzi, M.; Buffini, A.; Busoni, S.; Candelori, A.; Caner, A.; Castaldi, R.; Castro, A.; Catacchini, E.; Checcucci, B; Ciampolini, P.; Civinini, C.; Creanza, D.; D'Alessandro, R.; Da Rold, M.; Demaria, N.; De Palma, M.; Dell'Orso, R.; Della Marina, R.; Dutta, S.; Eklund, C.; Feld, L.; Fiore, L.; French, M.; Freudenreich, K.; Frey, A.; Fuertjes, A.; Giassi, A.; Giorgi, M.; Giraldo, A.; Glessing, B.; Gu, W.H.; Hall, G.; Hammarstrom, R.; Hebbeker, T.; Honma, A.; Hrubec, J.; Huhtinen, M.; Kaminsky, A.; Karimaki, V.; Koenig, St.; Krammer, M.; Lariccia, P.; Lenzi, M.; Loreti, M.; Leubelsmeyer, K.; Lustermann, W.; Maettig, P.; Maggi, G.; Mannelli, M.; Mantovani, G.; Marchioro, A.; Mariotti, C.; Martignon, G.; Evoy, B.Mc; Meschini, M.; Messineo, A.; Migliore, E.; My, S.; Paccagnella, A.; Palla, F.; Pandoulas, D.; Papi, A.; Parrini, G.; Passeri, D.; Pieri, M.; Piperov, S.; Potenza, R.; Radicci, V.; Raffaelli, F.; Raymond, M.; Rizzo, F.; Santocchia, A.; Schmitt, B.; Selvaggi, G.; Servoli, L.; Sguazzoni, G.; Siedling, R.; Silvestris, L.; Starodumov, A.; Stavitski, I.; Stefanini, G.; Surrow, B.; Tempesta, P.; Tonelli, G.; Tricomi, A.; Tuuva, T.; Vannini, C.; Verdini, P.G.; Viertel, G.; Xie, Z.; Yahong, Li; Watts, S.; Wittmer, B.

    2000-01-01

    This paper describes the Silicon microstrip Tracker of the CMS experiment at LHC. It consists of a barrel part with 5 layers and two endcaps with 10 disks each. About 10 000 single-sided equivalent modules have to be built, each one carrying two daisy-chained silicon detectors and their front-end electronics. Back-to-back modules are used to read-out the radial coordinate. The tracker will be operated in an environment kept at a temperature of T=-10 deg. C to minimize the Si sensors radiation damage. Heavily irradiated detectors will be safely operated due to the high-voltage capability of the sensors. Full-size mechanical prototypes have been built to check the system aspects before starting the construction

  6. Development of the data acquisition system for the Triple-GEM detectors for the upgrade of the CMS forward muon spectrometer

    CERN Document Server

    Abbaneo, D; Akl, M A; Ahmed, W; Armaingaud, C; Aspell, P; Assran, Y; Bally, S; Ban, Y; Banerjee, S; Barria, P; Benussi, L; Bhopatkar, V; Bianco, S; Bos, J; Bouhali, O; Cai, J; Calabria, C; Castaneda, A; Cauwenbergh, S; Celik, A; Christiansen, J; Colafranceschi, S; Colaleo, A; Conde Garcia, A; Dabrowski, M; De Lentdecker, G; De Oliveira, R; De Robertis, G; Dildick, S; Ferry, S; Flanagan, W; Gilmore, J; Guilloux, F; Gutierrez, A; Hoepfner, K; Hohlmann, M; Kamon, T; Karchin, P E; Khotilovich, V; Korntheuer, M; Krutelyov, S; Lenzi, T; Loddo, F; Maerschalk, T; Magazzu, G; Maggi, M; Maghrbi, Y; Marchioro, A; Marinov, A; Mazumdar, N; Merlin, J A; Mukhopadhyay, S; Nuzzo, S; Oliveri, E; Philipps, B; Piccolo, D; Postema, H; Radi, A; Radogna, R; Raffone, G; Ranieri, A; Rodrigues, A; Ropelewski, L; Safonov, A; Sakharov, A; Salva, S; Saviano, G; Sharma, A; Talvitie, J; Tatarinov, A; Teng, H; Turini, N; Tuuva, T; Twigger, J; Tytgat, M; van Stenis, M.; Verhagen, E; Yang, Y; Zaganidis, N; Zenoni, F

    2014-01-01

    In this contribution we will report on the progress of thedesign of the readout and data acquisition system being developedfor triple-GEM detectors which will be installed in the forwardregion (1.5 < |η| < 2.2) of the CMS muonspectrometer during the 2nd long shutdown of the LHC, expectedin the period 2017–2018. The system will be designed to take fulladvantage of current generic developments introduced for the LHCupgrades. The current design is based on the use of CERN GLIB boardshosted in micro-TCA crates for the off-detector electronics and theVersatile Link with the GBT chipset to link the front-endelectronics to the GLIB boards. In this contribution we willdescribe the physics goals, the hardware architectures and report onthe expected performance of the CMS GEM readout system, includingpreliminary timing resolution simulations.

  7. Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    CERN Document Server

    Baiatian, G; Emeliantchik, Igor; Massolov, V; Shumeiko, Nikolai; Stefanovich, R; Damgov, Jordan; Dimitrov, Lubomir; Genchev, Vladimir; Piperov, Stefan; Vankov, Ivan; Litov, Leander; Bencze, Gyorgy; Laszlo, Andras; Pal, Andras; Vesztergombi, Gyorgy; Zálán, Peter; Fenyvesi, Andras; Bawa, Harinder Singh; Beri, Suman Bala; Bhatnagar, Vipin; Kaur, Manjit; Kohli, Jatinder Mohan; Kumar, Arun; Singh, Jas Bir; Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Chendvankar, Sanjay; Dugad, Shashikant; Kalmani, Suresh Devendrappa; Katta, S; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Patil, Mandakini Ravindra; Reddy, L; Satyanarayana, B; Sharma, Seema; Sudhakar, Katta; Verma, Piyush; Hashemi, Majid; Mohammadi-Najafabadi, M; Paktinat, S; Golutvin, Igor; Kalagin, Vladimir; Kosarev, Ivan; Ladygin, Vladimir; Mescheryakov, G; Moissenz, P; Petrosian, A; Sergeyev, S; Smirnov, Vitaly; Vishnevskiy, Alexander; Volodko, Anton; Zarubin, Anatoli; Gavrilov, Vladimir; Gershtein, Yuri; Ilyina, N; Kaftanov, Vitali; Kisselevich, I; Kolossov, V; Krokhotin, Andrey; Kuleshov, Sergey; Litvintsev, Dmitri; Ulyanov, A; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Demianov, A; Gribushin, Andrey; Kodolova, Olga; Petrushanko, Sergey; Sarycheva, Ludmila; Teplov, V; Vardanyan, Irina; Yershov, A; Abramov, Victor; Goncharov, Petr; Kalinin, Alexey; Khmelnikov, Alexander; Korablev, Andrey; Korneev, Yury; Krinitsyn, Alexander; Kryshkin, V; Lukanin, Vladimir; Pikalov, Vladimir; Ryazanov, Anton; Talov, Vladimir; Turchanovich, L; Volkov, Alexey; Camporesi, Tiziano; De Visser, Theo; Vlassov, E; Aydin, Sezgin; Bakirci, Mustafa Numan; Cerci, Salim; Dumanoglu, Isa; Eskut, Eda; Kayis-Topaksu, A; Koylu, S; Kurt, Pelin; Onengüt, G; Ozkurt, Halil; Polatoz, A; Sogut, Kenan; Topakli, Huseyin; Vergili, Mehmet; Yetkin, Taylan; Cankocak, Kerem; Esendemir, Akif; Gamsizkan, Halil; Güler, M; Ozkan, Cigdem; Sekmen, Sezen; Serin-Zeyrek, M; Sever, Ramazan; Yazgan, Efe; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Dindar, Kamile; Gülmez, Erhan; Isiksal, Engin; Kaya, Mithat; Ozkorucuklu, Suat; Levchuk, Leonid; Sorokin, Pavel; Senchishin, V; Hauptman, John M; Abdullin, Salavat; Elias, John E; Elvira, D; Freeman, Jim; Green, Dan; Los, Serguei; O'Dell, Vivian; Ronzhin, Anatoly; Suzuki, Ichiro; Vidal, Richard; Whitmore, Juliana; Arcidy, M; Hazen, Eric; Heering, Arjan Hendrix; Lawlor, C; Lazic, Dragoslav; Machado, Emanuel; Rohlf, James; Varela, F; Wu, Shouxiang; Baden, Drew; Bard, Robert; Eno, Sarah Catherine; Grassi, Tullio; Jarvis, Chad; Kellogg, Richard G; Kunori, Shuichi; Mans, Jeremy; Skuja, Andris; Podrasky, V; Sanzeni, Christopher; Winn, Dave; Akgun, Ugur; Ayan, S; Duru, Firdevs; Merlo, Jean-Pierre; Mestvirishvili, Alexi; Miller, Michael; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Schmidt, Ianos; Akchurin, Nural; Carrell, Kenneth Wayne; Gumus, Kazim; Kim, Heejong; Spezziga, Mario; Thomas, Ray; Baarmand, Marc M; Mermerkaya, Hamit; Ralich, Robert; Vodopiyanov, Igor; Kramer, Laird; Linn, Stephan; Markowitz, Pete; Cushman, Priscilla; Ma, Yousi; Sherwood, Brian; Cremaldi, Lucien Marcus; Reidy, Jim; Sanders, David A; Karmgard, Daniel John; Ruchti, Randy; Fisher, Wade Cameron; Tully, Christopher; Bodek, Arie; De Barbaro, Pawel; Budd, Howard; Chung, Yeon Sei; Haelen, T; Hagopian, Sharon; Hagopian, Vasken; Johnson, Kurtis F; Barnes, Virgil E; Laasanen, Alvin T

    2007-01-01

    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are...

  8. Fine-mesh photodetectors for CMS Endcap Electromagnetic Calorimeter

    CERN Document Server

    Bajanov, N A; Gusev, Yu I; Klechneva, T Yu; Kovalev, A I; Levtchenko, L A; Moroz, F V; Seliverstov, D M; Kachanov, V A; Golubev, N A; Frolov, V A; Lukyanov, V N; Mamaeva, G A; Prilutskaya, D M

    2000-01-01

    The behaviour of fine-mesh vacuum phototriodes (VPTs) with the external diameters of 21 and 35 mm has been investigated in an axial magnetic field up to 4 T in view of their applications as readout devices for CMS Endcap Electromagnetic Calorimeter. The measured VPT parameters are: the photocathode's sensitivity and its homogeneity, the gain in zero and 4 T magnetic field at tilt angles corresponding to the pseudorapidity range of CMS ECAL Endcap 1.48-3.0 as a function of fine-mesh cell dimensions, excess noise factor and the stability of the photocathode response under the illumination by light emission diodes (LED) and the irradiation by 14 MeV neutrons. Phototriodes with 100 lines per mm fine-mesh and 25 mm external diameter are found to be the best candidates for coupling with rear PbWO/sub 4/ crystals by dimensions of 30*30 mm, proposed to be used in CMS ECAL Endcaps. VPTs provide a gain of the order (6-8) in a 4 T magnetic field and an excess noise factor of 2-2.5 under illumination of a full photocatho...

  9. Studies for the Commissioning of the CERN CMS Silicon Strip Tracker

    CERN Document Server

    Bloch, Christoph; Abbaneo, Duccio; Fabjan, Christian Wolfgang

    2008-01-01

    In 2008 the Large Hadron Collider (LHC) at CERN will start producing proton-proton collisions of unprecedented energy. One of its main experiments is the Compact Muon Solenoid (CMS), a general purpose detector, optimized for the search of the Higgs boson and super symmetric particles. The discovery potential of the CMS detector relies on a high precision tracking system, made of a pixel detector and the largest silicon strip Tracker ever built. In order to operate successfully a device as complex as the CMS silicon strip Tracker, and to fully exploit its potential, the properties of the hardware need to be characterized as precisely as possible, and the reconstruction software needs to be commissioned with physics signals. A number of issues were identified and studied to commission the detector, some of which concern the entire Tracker, while some are specific to the Tracker Outer Barrel (TOB): - the time evolution of the signals in the readout electronics need to be precisely measured and correctly simulate...

  10. The CMS ECAL Upgrade for Precision Crystal Calorimetry at the HL-LHC

    CERN Document Server

    Jofrehei, Arash

    2017-01-01

    The Compact Muon Solenoid Experiment (CMS) is operating at the Large Hadron Collider (LHC) with proton-proton collisions at 13 TeV center-of-mass energy and at a bunch spacing of 25 ns. Challenging running conditions for CMS are expected after the High-Luminosity upgrade of the LHC (HL-LHC). We review the CMS ECAL crystal calorimeter upgrade and present results from the first test beam studies. Particular challenges at HL-LHC are the harsh radiation environment, the increasing data rates and the extreme level of pile-up events, with up to 200 simultaneous proton-proton collisions. Precision timing can be exploited to reduce the effect of the pile-up. We report on the timing resolution studies performed with test-beams. We discuss the new readout and trigger electronics, which must be upgraded due to the increased trigger and latency requirements at the HL-LHC.

  11. The CMS Hadron Forward Calorimeter Upgrade during Phase I

    CERN Document Server

    Gulmez, Erhan

    2014-01-01

    The CMS Hadron Forward Calorimeter will be upgraded during phase 1. The upgrade will include the replacement of the current PMTs with the 4-anode ones and the readout electronics. Currently, stray muons hitting the PMT windows produce Cherenkov light causing erroneous signals. These signals are detrimental to the triggering and physic results, since such signals mimic very high energy events. The new 4-anode PMTs are selected because of their thin windows to reduce the Cherenkov light production. Additional anodes also provide information to eliminate such signals. These new PMTs have been tested extensively to understand their characteristics and to develop the algorithms to eliminate the unwanted signals. Eventually, the current read out will be replaced with two-channel readout electronics for each PMT. The overall expected improvement on the physics results will also be discussed.

  12. CMS 2006 - CMS France days; CMS 2006 les journees CMS FRANCE

    Energy Technology Data Exchange (ETDEWEB)

    Huss, D.; Dobrzynski, L.; Virdee, J.; Boudoule, G.; Fontaine, J.C.; Faure, J.L.; Paganini, P.; Mathez, H.; Gross, L.; Charlot, C.; Trunov, A.; Patois, Y.; Busson, P.; Maire, M.; Berthon, U.; Todorov, T.; Beaudette, F.; Sirois, Y.; Baffioni, S.; Beauceron, S.; Delmeire, E.; Agram, J.L.; Goerlach, U.; Mangeol, D.; Salerno, R.; Bloch, D.; Lassila-Perini, K.; Blaha, J.; Drobychev, G.; Gras, P.; Hagenauer, M.; Denegri, D.; Lounis, A.; Faccio, F.; Lecoq, J

    2006-07-01

    These CMS talks give the opportunity for all the teams working on the CMS (Compact Muon Spectrometer) project to present the status of their works and to exchange ideas. 5 sessions have been organized: 1) CMS status and perspectives, 2) contributions of the different laboratories, 3) software and computation, 4) physics with CMS (particularly the search for the Higgs boson), and 5) electronic needs. This document gathers the slides of the presentations.

  13. The CMS silicon strip tracker

    International Nuclear Information System (INIS)

    Focardi, E.; Albergo, S.; Angarano, M.; Azzi, P.; Babucci, E.; Bacchetta, N.; Bader, A.; Bagliesi, G.; Bartalini, P.; Basti, A.; Biggeri, U.; Bilei, G.M.; Bisello, D.; Boemi, D.; Bosi, F.; Borrello, L.; Bozzi, C.; Braibant, S.; Breuker, H.; Bruzzi, M.; Candelori, A.; Caner, A.; Castaldi, R.; Castro, A.; Catacchini, E.; Checcucci, B.; Ciampolini, P.; Civinini, C.; Creanza, D.; D'Alessandro, R.; Da Rold, M.; Demaria, N.; De Palma, M.; Dell'Orso, R.; Marina, R. Della; Dutta, S.; Eklund, C.; Elliott-Peisert, A.; Feld, L.; Fiore, L.; French, M.; Freudenreich, K.; Fuertjes, A.; Giassi, A.; Giraldo, A.; Glessing, B.; Gu, W.H.; Hall, G.; Hammerstrom, R.; Hebbeker, T.; Hrubec, J.; Huhtinen, M.; Kaminsky, A.; Karimaki, V.; Koenig, St.; Krammer, M.; Lariccia, P.; Lenzi, M.; Loreti, M.; Luebelsmeyer, K.; Lustermann, W.; Maettig, P.; Maggi, G.; Mannelli, M.; Mantovani, G.; Marchioro, A.; Mariotti, C.; Martignon, G.; Evoy, B. Mc; Meschini, M.; Messineo, A.; My, S.; Paccagnella, A.; Palla, F.; Pandoulas, D.; Parrini, G.; Passeri, D.; Pieri, M.; Piperov, S.; Potenza, R.; Raffaelli, F.; Raso, G.; Raymond, M.; Santocchia, A.; Schmitt, B.; Selvaggi, G.; Servoli, L.; Sguazzoni, G.; Siedling, R.; Silvestris, L.; Skog, K.; Starodumov, A.; Stavitski, I.; Stefanini, G.; Tempesta, P.; Tonelli, G.; Tricomi, A.; Tuuva, T.; Vannini, C.; Verdini, P.G.; Viertel, G.; Xie, Z.; Wang, Y.; Watts, S.; Wittmer, B.

    1999-01-01

    The Silicon Strip Tracker (SST) is the intermediate part of the CMS Central Tracker System. SST is based on microstrip silicon devices and in combination with pixel detectors and the Microstrip Gas Chambers aims at performing pattern recognition, track reconstruction and momentum measurements for all tracks with p T ≥2 GeV/c originating from high luminosity interactions at √s=14 TeV at LHC. We aim at exploiting the advantages and the physics potential of the precise tracking performance provided by the microstrip silicon detectors on a large scale apparatus and in a much more difficult environment than ever. In this paper we describe the actual SST layout and the readout system. (author)

  14. Members of the Forum Engelberg visit CERN

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    The Forum Engelberg is an annual interdisciplinary conference held in Engelberg, Switzerland intended to act as an international platform for debate and exchange of views on key issues affecting scientific research, technology, economics and philosophy. Its President, Hubert Curien - former French Minister of Research and Space Research, and President of the CERN Council from 1994 to 1996 - is pictured here. Photo 01: Hubert Curien in front of the first half of the CMS detector's barrel hadronic calorimeter (HCAL). The barrel HCAL is a cylindrical structure which will surround the collision region and measure the energy of quarks and jets emerging at large angles relative to the beam direction. Photo 02: Hubert Curien (left) with Bernard Ecoffey, Founder of the Forum Engelberg, in front of the first half of the CMS detector's barrel hadronic calorimeter.

  15. A micro-TCA based data acquisition system for the Triple-GEM detectors for the upgrade of the CMS forward muon spectrometer

    CERN Document Server

    Lenzi, Thomas

    2016-01-01

    We will present the electronic and DAQ system being developed for TripleGEM detectors which will be installed in the CMS muon spectrometer. The microTCA system uses an Advanced Mezzanine Card equipped with an FPGA and the Versatile Link with the GBT chipset to link the front and back-end. On the detector an FPGA mezzanine board, the OptoHybrid, has to collect the data from the detector readout chips to transmit them optically to the microTCA boards using the GBT protocol. We will describe the hardware architecture, report on the status of the developments, and present results obtained with the system.In this contribution we will report on the progress of the design of the electronic readout and data acquisition (DAQ) system being developed for Triple-GEM detectors which will be installed in the forward region (1.5 < eta < 2.2) of the CMS muon spectrometer during the 2nd long shutdown of the LHC, planed for the period 2018-2019. The architecture of the Triple-GEM readout system is based on the use of the...

  16. The CMS ECAL Upgrade for Precision Crystal Calorimetry at the HL-LHC

    CERN Document Server

    Petyt, David Anthony

    2018-01-01

    The electromagnetic calorimeter (ECAL) of the Compact Muon Solenoid Experiment (CMS) is operating at the Large Hadron Collider (LHC) in 2016 with proton-proton collisions at 13 TeV center-of-mass energy and at a bunch spacing of 25 ns. Challenging running conditions for CMS are expected after the High-Luminosity upgrade of the LHC (HL-LHC). We review the design and R and D studies for the CMS ECAL crystal calorimeter upgrade and present first test beam studies. Particular challenges at HL-LHC are the harsh radiation environment, the increasing data rates and the extreme level of pile-up events, with up to 200 simultaneous proton-proton collisions. We present test beam results of hadron irradiated PbWO$_{4}$ crystals up to fluences expected at the HL-LHC. We also report on the R and D for the new readout and trigger electronics, which must be upgraded due to the increased trigger and latency requirements at the HL-LHC.

  17. Tracking at High Level Trigger in CMS

    CERN Document Server

    Tosi, Mia

    2016-01-01

    The trigger systems of the LHC detectors play a crucial role in determining the physics capabili- ties of the experiments. A reduction of several orders of magnitude of the event rate is needed to reach values compatible with detector readout, offline storage and analysis capability. The CMS experiment has been designed with a two-level trigger system: the Level-1 Trigger (L1T), implemented on custom-designed electronics, and the High Level Trigger (HLT), a stream- lined version of the CMS offline reconstruction software running on a computer farm. A software trigger system requires a trade-off between the complexity of the algorithms, the sustainable out- put rate, and the selection efficiency. With the computing power available during the 2012 data taking the maximum reconstruction time at HLT was about 200 ms per event, at the nominal L1T rate of 100 kHz. Track reconstruction algorithms are widely used in the HLT, for the reconstruction of the physics objects as well as in the identification of b-jets and ...

  18. Digital Power Consumption Estimations for CHIPIX65 Pixel Readout Chip

    CERN Document Server

    Marcotulli, Andrea

    2016-01-01

    New hybrid pixel detectors with improved resolution capable of dealing with hit rates up to 3 GHz/cm2 will be required for future High Energy Physics experiments in the Large Hadron Collider (LHC) at CERN. Given this, the RD53 collaboration works on the design of the next generation pixel readout chip needed for both the ATLAS and CMS detector phase 2 pixel upgrades. For the RD53 demonstrator chip in 65nm CMOS technology, different architectures are considered. In particular the purpose of this work is estimating the power consumption of the digital architecture of the readout ASIC developed by CHIPIX65 project of the INFN National Scientific Committee. This has been done with modern chip design tools integrated with the VEPIX53 simulation framework that has been developed within the RD53 collaboration in order to assess the performance of the system in very high rate, high energy physics experiments.

  19. Qualification Procedures of the CMS Pixel Barrel Modules

    CERN Document Server

    Starodumov, A; Horisberger, R.; Kastli, H.Chr.; Kotlinski, D.; Langenegger, U.; Meier, B.; Rohe, T.; Trueb, P.

    2006-01-01

    The CMS pixel barrel system will consist of three layers built of about 800 modules. One module contains 66560 readout channels and the full pixel barrel system about 48 million channels. It is mandatory to test each channel for functionality, noise level, trimming mechanism, and bump bonding quality. Different methods to determine the bump bonding yield with electrical measurements have been developed. Measurements of several operational parameters are also included in the qualification procedure. Among them are pixel noise, gains and pedestals. Test and qualification procedures of the pixel barrel modules are described and some results are presented.

  20. Performance of the CMS precision electromagnetic calorimeter at LHC Run II and prospects for High-Luminosity LHC

    Science.gov (United States)

    Zhang, Zhicai

    2018-04-01

    Many physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high-resolution electron and photon energy measurements. Following the excellent performance achieved during LHC Run I at center-of-mass energies of 7 and 8 TeV, the CMS electromagnetic calorimeter (ECAL) is operating at the LHC with proton-proton collisions at 13 TeV center-of-mass energy. The instantaneous luminosity delivered by the LHC during Run II has achieved unprecedented levels. The average number of concurrent proton-proton collisions per bunch-crossing (pileup) has reached up to 40 interactions in 2016 and may increase further in 2017. These high pileup levels necessitate a retuning of the ECAL readout and trigger thresholds and reconstruction algorithms. In addition, the energy response of the detector must be precisely calibrated and monitored. We present new reconstruction algorithms and calibration strategies that were implemented to maintain the excellent performance of the CMS ECAL throughout Run II. We will show performance results from the 2015-2016 data taking periods and provide an outlook on the expected Run II performance in the years to come. Beyond the LHC, challenging running conditions for CMS are expected after the High-Luminosity upgrade of the LHC (HL-LHC) . We review the design and R&D studies for the CMS ECAL and present first test beam studies. Particular challenges at HL-LHC are the harsh radiation environment, the increasing data rates, and the extreme level of pile-up events, with up to 200 simultaneous proton-proton collisions. We present test beam results of hadron irradiated PbWO crystals up to fluences expected at the HL-LHC . We also report on the R&D for the new readout and trigger electronics, which must be upgraded due to the increased trigger and latency requirements at the HL-LHC.

  1. First test of a CMS DT chamber equipped with full electronics in a muon beam

    CERN Multimedia

    Jesus Puerta-Pelayo

    2003-01-01

    A CMS DT chamber of MB3 type, equipped with the final version of a minicrate (containing all on-chamber trigger and readout electronics), was tested in a muon beam for the first time. The beam was bunched in 25 ns spills, allowing an LHC-like response of the chamber trigger. This test confirmed the excellent performance of the trigger design.

  2. Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

    CERN Document Server

    Abbrescia, Marcello; Benussi, Luigi; Bianco, Stefano; Cauwenbergh, Simon Marc D; Ferrini, Mauro; Muhammad, Saleh; Passamontic, L; Pierluigi, Daniele; Piccolo, Davide; Primavera, Federica; Russo, Alessandro; Savianoc, G; Tytgat, Michael

    2016-01-01

    The operations of Resistive Plate Chambers in LHC experiments require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In view of the CMS experiment upgrade several tests are ongoing to measure the performance of the detector in terms of efficiency, streamer probability, induced charge and time resolution. Prototype chambers with readout pads and with the standard cms electronic setup are under test. In this talk preliminary results on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze and with CO2 based gas mixtures are presented and discussed for the possible application in the CMS experiment.

  3. COMMISSIONING AND DETECTOR PERFORMANCE GROUPS (DPG)

    CERN Multimedia

    Tiziano Camporesi

    Pit commissioning activities The last 4 months have seen various major achievements in hardware commissioning, global data taking, readiness of the DPGs to deal with LHC data flows and alignment and calibration workflows. Since February, the global commissioning has been characterized on the one side by more and more of the final CMS detector becoming available for global readout and triggering and on the other side by consolidation of many of the central software infrastructure and of most of the services infrastructure. The reliability of services like cooling, power, gas has markedly improved with respect to what we observed in the second half of 2007.   Of particular note are the delivery of all low voltage power supplies, the commissioning of the final power distribution, the progressive commissioning ( still ongoing)  of the Detector Safety System and of the associated DCS early warning and alarm system. On the detector side, while already we are used to seeing all of HCAL being exe...

  4. AVME readout module for multichannel ASIC characterization

    International Nuclear Information System (INIS)

    Borkar, S.P.; Lalwani, S.K.; Ghodgaonkar, M.D.; Kataria, S.K.; Reynaud, Serge; )

    2004-01-01

    Electronics Division, BARC has been working on the development of multi-channel ASIC, called SPAIR (Silicon-strip Pulse Amplifier Integrated Readout). It contains 8 channels of preamplifier, shaper and track-and-hold circuitry. Electronics Division has also actively participated in development of test setup for the front-end ASIC, called PACE, for the preshower detector of the Compact Muon Solenoid (CMS) Experiment at CERN, Geneva. PACE is a 32 channel ASIC for silicon strip detector, containing preamplifier, shaper, calibration circuitry, switched capacitor array, readout amplifier per channel and an analog multiplexer. A VME Readout Module, (VRM) is developed which can be utilized in data acquisition from ASICs like PACE and SPAIR. The VRM can also be used as the Detector Dependent Unit for digitally processing the data received from the front-end electronics on the 16-bit LVDS port. The processed, data can be read by the VME system. Thus the VRM is very useful in building an ASIC characterization system and/or the automated ASIC production testing system. It can be used also to build the applications using such ASICs. To cater to various requirements arising in future, variety of VME modules are to be developed like ADCs, DACs and D 1/0. VME interface remains a common part to all these modules. The different functional blocks of these modules can be designed and fabricated on small piggyback boards (called Test Boards) and mounted on the VRM, which provides the common VME interface. The design details and uses of VRM are presented here. (author)

  5. CMS 2006 - CMS France days

    International Nuclear Information System (INIS)

    Huss, D.; Dobrzynski, L.; Virdee, J.; Boudoule, G.; Fontaine, J.C.; Faure, J.L.; Paganini, P.; Mathez, H.; Gross, L.; Charlot, C.; Trunov, A.; Patois, Y.; Busson, P.; Maire, M.; Berthon, U.; Todorov, T.; Beaudette, F.; Sirois, Y.; Baffioni, S.; Beauceron, S.; Delmeire, E.; Agram, J.L.; Goerlach, U.; Mangeol, D.; Salerno, R.; Bloch, D.; Lassila-Perini, K.; Blaha, J.; Drobychev, G.; Gras, P.; Hagenauer, M.; Denegri, D.; Lounis, A.; Faccio, F.; Lecoq, J.

    2006-01-01

    These CMS talks give the opportunity for all the teams working on the CMS (Compact Muon Spectrometer) project to present the status of their works and to exchange ideas. 5 sessions have been organized: 1) CMS status and perspectives, 2) contributions of the different laboratories, 3) software and computation, 4) physics with CMS (particularly the search for the Higgs boson), and 5) electronic needs. This document gathers the slides of the presentations

  6. The CMS ECAL Upgrade for Precision Crystal Calorimetry at the HL-LHC

    CERN Document Server

    Marinelli, Nancy

    2017-01-01

    The Compact Muon Solenoid Experiment (CMS) is operating at the Large Hadron Collider (LHC) with proton-proton collisions at 13 TeV center-of-mass energy and at a bunch spacing of 25 ns. New further challenging running conditions for CMS are expected after the High-Luminosity upgrade of the LHC (HL--LHC). The CMS electromagnetic calorimeter (ECAL) will need to be upgraded to substain the hardned environment.The design and R\\ and D studies for the ECAL upgrade are presented together with first test beam studies. Particular challenges at HL--LHC are the harsh radiation environment, the increasing data rates and the extreme level of pile-up events, with up to 200 simultaneous proton-proton collisions. Precision timing can be exploited to reduce the effect of the pile-up. Time resolution measurementscarried out during test-beams are shown. Plans are also shown for R\\ and D for the new readout and trigger electronics, which must be upgraded due to the increased trigger and latency requirements at the HL--LHC

  7. Phase1 upgrade of the CMS-HF Calorimeter

    CERN Document Server

    Gulmez, Erhan

    2016-01-01

    In this presentation, results of the Phase I upgrade of the CMS Hadron Forward Calorimeter (HF) are discussed. The CMS-HF Calorimeter was using regular PMTs. Cherenkov light produced in the quartz fibers embedded in the iron absorber was read out with the PMTs. However, occasionally, stray muons hitting the PMT windows cause Cherenkov radiation in the PMT itself and produce large signals. These large signals mimic a very high-energy particle and are tagged as important by the trigger. To reduce this problem, PMTs had to be replaced. The four-anode PMTs that were chosen have thinner windows; thereby reducing the Cherenkov radiation in the PMT window. As part of the upgrade, the read-out electronics is to be replaced so that the PMTs are read out in two channels by connecting each pair of anodes to a single channel. Information provided by these two channels will help us reject the false signals due to the stray muons since the Cherenkov radiation in the PMT window is more likely to produce a signal only in one...

  8. Test results from a prototype lead tungstate crystal calorimeter with vacuum phototriode readout for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Apollonio, M; Barber, G; Bell, K; Britton, D; Brooke, J; Brown, R; Bourotte, J; Camanzi, B; Cockerill, D; Davies, G; Devitsin, E; Gninenko, S; Golubev, N; Goussev, Y; Grafstroem, P; Haguenauer, M; Head, R; Heath, H; Hobson, P; Inyakin, A; Katchanov, V; Kirsanov, M; Lintern, L; Lodge, A; Mcleod, E; Nash, S; Newbold, D; Ukhanov, M; Postoev, V; Patalakha, D; Presland, A; Probert, M; Seez, C; Semeniouk, I; Seliverstov, D; Smith, B; Sproston, M; Tapper, R; Tchuiko, B

    2002-05-21

    Tests of a prototype for the electromagnetic calorimeter (ECAL) of the compact muon solenoid experiment (CMS) at the large hadron collider are described. The basic unit for the endcap ECAL in CMS is a 'supercrystal' of 25 lead tungstate crystals. Results are presented from tests of the first full-sized supercrystal in electron beams and in a 3 T magnetic field. The supercrystal was exposed to electron beams with energies from 25 to 180 GeV. An energy resolution ({sigma}{sub E}/E) of (0.48{+-}0.01)% was measured at 180 GeV.

  9. Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

    International Nuclear Information System (INIS)

    Abbrescia, M.; Muhammad, S.; Saviano, G.; Auwegem, P. Van; Cauwenbergh, S.; Tytgat, M.; Benussi, L.; Bianco, S.; Passamonti, L.; Pierluigi, D.; Piccolo, D.; Primavera, F.; Russo, A.; Ferrini, M.

    2016-01-01

    The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In view of the CMS experiment upgrade, several tests are ongoing to measure the performance of the detector with these new ecological gas mixtures, in terms of efficiency, streamer probability, induced charge and time resolution. Prototype chambers with readout pads and with the standard CMS electronic setup are under test. In this paper preliminary results on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze, with CO 2 and CF 3 I based gas mixtures are presented and discussed for the possible application in the CMS experiment.

  10. Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

    CERN Document Server

    Abbrescia, M.

    2016-01-01

    The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In view of the CMS experiment upgrade, several tests are ongoing to measure the performance of the detector with these new ecological gas mixtures, in terms of efficiency, streamer probability, induced charge and time resolution. Prototype chambers with readout pads and with the standard CMS electronic setup are under test. In this paper preliminary results on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze, with CO2 and CF3I based gas mixtures are presented and discussed for the possible application in the CMS experiment.

  11. CMS Level-1 Upgrade Calorimeter Trigger Prototype Development

    CERN Document Server

    Klabbers, Pamela Renee

    2013-01-01

    As the LHC increases luminosity and energy, it will become increasingly difficult to select interesting physics events and remain within the readout bandwidth limitations. An upgrade to the CMS Calorimeter Trigger implementing more complex algorithms is proposed. It utilizes AMC cards with Xilinx FPGAs running in micro-TCA crate with card interconnections via crate backplanes and optical links operating at up to 10 Gbps. Prototype cards with Virtex-6 and Virtex-7 FPGAs have been built and software frameworks for operation and monitoring developed. The physics goals, hardware architectures, and software will be described in this talk. More details can be found in a separate poster at this conference.

  12. Radiation hardness of CMS pixel barrel modules

    CERN Document Server

    Rohe, T; Erdmann, W; Kästli, H C; Khalatyan, S; Meier, B; Radicci, V; Sibille, J

    2010-01-01

    Pixel detectors are used in the innermost part of the multi purpose experiments at LHC and are therefore exposed to the highest fluences of ionising radiation, which in this part of the detectors consists mainly of charged pions. The radiation hardness of all detector components has thoroughly been tested up to the fluences expected at the LHC. In case of an LHC upgrade, the fluence will be much higher and it is not yet clear how long the present pixel modules will stay operative in such a harsh environment. The aim of this study was to establish such a limit as a benchmark for other possible detector concepts considered for the upgrade. As the sensors and the readout chip are the parts most sensitive to radiation damage, samples consisting of a small pixel sensor bump-bonded to a CMS-readout chip (PSI46V2.1) have been irradiated with positive 200 MeV pions at PSI up to 6E14 Neq and with 21 GeV protons at CERN up to 5E15 Neq. After irradiation the response of the system to beta particles from a Sr-90 source w...

  13. CMS DOCUMENTATION

    CERN Multimedia

    CMS TALKS AT MAJOR MEETINGS The agenda and talks from major CMS meetings can now be electronically accessed from the iCMS Web site. The following items can be found on: http://cms.cern.ch/iCMS/ General - CMS Weeks (Collaboration Meetings), CMS Weeks Agendas The talks presented at the Plenary Sessions. LHC Symposiums Management - CB - MB - FB - FMC Agendas and minutes are accessible to CMS members through their AFS account (ZH). However some linked documents are restricted to the Board Members. FB documents are only accessible to FB members. LHCC The talks presented at the ‘CMS Meetings with LHCC Referees’ are available on request from the PM or MB Country Representative. Annual Reviews The talks presented at the 2006 Annual reviews are posted.   CMS DOCUMENTS It is considered useful to establish information on the first employment of CMS doctoral students upon completion of their theses. Therefore it is requested that Ph.D students inform the CMS Secretariat a...

  14. CMS DOCUMENTATION

    CERN Multimedia

    CMS TALKS AT MAJOR MEETINGS The agenda and talks from major CMS meetings can now be electronically accessed from the iCMS Web site. The following items can be found on: http://cms.cern.ch/iCMS/ General - CMS Weeks (Collaboration Meetings), CMS Weeks Agendas The talks presented at the Plenary Sessions. LHC Symposiums Management - CB - MB - FB - FMC Agendas and minutes are accessible to CMS members through their AFS account (ZH). However some linked documents are restricted to the Board Members. FB documents are only accessible to FB members. LHCC The talks presented at the ‘CMS Meetings with LHCC Referees’ are available on request from the PM or MB Country Representative. Annual Reviews The talks presented at the 2006 Annual reviews are posted. CMS DOCUMENTS It is considered useful to establish information on the first employment of CMS doctoral students upon completion of their theses. Therefore it is requested that Ph.D students inform the CMS Secretariat about the natu...

  15. CMS DOCUMENTATION

    CERN Multimedia

    CMS TALKS AT MAJOR MEETINGS The agenda and talks from major CMS meetings can now be electronically accessed from the iCMS Web site. The following items can be found on: http://cms.cern.ch/iCMS/ General - CMS Weeks (Collaboration Meetings), CMS Weeks Agendas The talks presented at the Plenary Sessions. LHC Symposiums Management - CB - MB - FB - FMC Agendas and minutes are accessible to CMS members through their AFS account (ZH). However some linked documents are restricted to the Board Members. FB documents are only accessible to FB members. LHCC The talks presented at the ‘CMS Meetings with LHCC Referees’ are available on request from the PM or MB Country Representative. Annual Reviews The talks presented at the 2006 Annual reviews are posted. CMS DOCUMENTS It is considered useful to establish information on the first employment of CMS doctoral students upon completion of their theses. Therefore it is requested that Ph.D students inform the CMS Secretariat about the natur...

  16. CMS DOCUMENTATION

    CERN Multimedia

    CMS TALKS AT MAJOR MEETINGS The agenda and talks from major CMS meetings can now be electronically accessed from the iCMS Web site. The following items can be found on: http://cms.cern.ch/iCMS/ Management- CMS Weeks (Collaboration Meetings), CMS Weeks Agendas The talks presented at the Plenary Sessions. Management - CB - MB - FB Agendas and minutes are accessible to CMS members through their AFS account (ZH). However some linked documents are restricted to the Board Members. FB documents are only accessible to FB members. LHCC The talks presented at the ‘CMS Meetings with LHCC Referees’ are available on request from the PM or MB Country Representative. Annual Reviews The talks presented at the 2007 Annual reviews are posted. CMS DOCUMENTS It is considered useful to establish information on the first employment of CMS doctoral students upon completion of their theses. Therefore it is requested that Ph.D students inform the CMS Secretariat about the nature of em¬pl...

  17. CMS DOCUMENTATION

    CERN Multimedia

    CMS TALKS AT MAJOR MEETINGS The agenda and talks from major CMS meetings can now be electronically accessed from the iCMS Web site. The following items can be found on: http://cms.cern.ch/iCMS/ Management- CMS Weeks (Collaboration Meetings), CMS Weeks Agendas The talks presented at the Plenary Sessions. Management - CB - MB - FB Agendas and minutes are accessible to CMS members through their AFS account (ZH). However some linked documents are restricted to the Board Members. FB documents are only accessible to FB members. LHCC The talks presented at the ‘CMS Meetings with LHCC Referees’ are available on request from the PM or MB Country Representative. Annual Reviews The talks presented at the 2007 Annual reviews are posted. CMS DOCUMENTS It is considered useful to establish information on the first employment of CMS doctoral students upon completion of their theses. Therefore it is requested that Ph.D students inform the CMS Secretariat about the nature of employment and ...

  18. CMS DOCUMENTATION

    CERN Multimedia

    CMS TALKS AT MAJOR MEETINGS The agenda and talks from major CMS meetings can now be electronically accessed from the iCMS Web site. The following items can be found on: http://cms.cern.ch/iCMS/ General - CMS Weeks (Collaboration Meetings), CMS Weeks Agendas The talks presented at the Plenary Sessions. LHC Symposiums Management - CB - MB - FB - FMC Agendas and minutes are accessible to CMS members through their AFS account (ZH). However some linked documents are restricted to the Board Members. FB documents are only accessible to FB members. LHCC The talks presented at the ‘CMS Meetings with LHCC Referees’ are available on request from the PM or MB Country Representative. Annual Reviews The talks presented at the 2006 Annual reviews are posted. CMS DOCUMENTS It is considered useful to establish information on the first employment of CMS doctoral students upon completion of their theses. Therefore it is requested that Ph.D students inform the CMS Secretariat about the na...

  19. Calibration by precise charge injection of a sub-detector of CMS; Calibration par injection de charge du calorimetre electromagnetique de CMS

    Energy Technology Data Exchange (ETDEWEB)

    Yong-Wook Baek

    2001-01-26

    This thesis was carried out within the framework of the international collaboration which has the responsibility of the experience CMS (Compact Muon Solenoid) on LHC, at CERN. The physics of the fundamental particles which will be explored by this experiment is described within the standard model. The configuration of sub-detector of CMS is briefly described, with a particular weight on the read-out chain of the electromagnetic calorimeter. The work carried out to calibrate this chain by a precise charge injection at the input of preamplifiers is described. The 4 integrated circuits CTRL, TPLS, DAC, and injector which will constitute the components of this chain of calibration are described. The circuit of injection, which is the main circuit in this project, was imagined and developed at the laboratory in DMILL technology. This injector generates a signal which has a form identical to the signal of the detector. The measurements on the linearity of the injectors are presented. In order to know its behavior under real conditions (flow of neutrons {approx} 2 x 10{sup 13} neutrons/cm{sup 2}/10 years) where this circuit is installed in detector CMS, we submitted the prototypes of injector to irradiation and the results are summarized. The research and development on this circuit produced an integrated circuit hardened to irradiations, whose variation of slope is lower than 0.25% for an integrated of 2 x 10{sup 13} neutrons/cm{sup 2} and indestructible under 10{sup 15} neutrons/cm{sup 2}. This circuit has satisfactory qualities to be assembled on the electronic card which will treat the data of calorimeter ECAL of CMS. (author)

  20. CMS DOCUMENTATION

    CERN Multimedia

    CMS TALKS AT MAJOR MEETINGS The agenda and talks from major CMS meetings can now be electronically accessed from the ICMS Web site. The following items can be found on: http://cms.cern.ch/iCMS Management – CMS Weeks (Collaboration Meetings), CMS Weeks Agendas The talks presented at the Plenary Sessions. Management – CB – MB – FB Agendas and minutes are accessible to CMS members through Indico. LHCC The talks presented at the ‘CMS Meetings with LHCC Referees’ are available on request from the PM or MB Country Representative. Annual Reviews The talks presented at the 2008 Annual Reviews are posted in Indico. CMS DOCUMENTS It is considered useful to establish information on the first employment of CMS doctoral student upon completion of their theses.  Therefore it is requested that Ph.D students inform the CMS Secretariat about the nature of employment and name of their first employer. The Notes, Conference Reports and Theses published si...

  1. The CMS crystal calorimeter

    CERN Document Server

    Lustermann, W

    2004-01-01

    The measurement of the energy of electrons and photons with very high accuracy is of primary importance far the study of many physics processes at the Large Hadron Collider (LHC), in particular for the search of the Higgs Boson. The CMS experiment will use a crystal calorimeter with pointing geometry, almost covering 4p, as it offers a very good energy resolution. It is divided into a barrel composed of 61200 lead tungstate crystals, two end-caps with 14648 crystals and a pre-shower detector in front of the end-cap. The challenges of the calorimeter design arise from the high radiation environment, the 4 Tesla magnetic eld, the high bunch crossing rate of 40 MHz and the large dynamic range, requiring the development of fast, radiation hard crystals, photo-detectors and readout electronics. An overview of the construction and design of the calorimeter will be presented, with emphasis on some of the details required to meet the demanding performance goals. 19 Refs.

  2. Custom integrated front-end circuit for the CMS electromagnetic calorimeter

    CERN Document Server

    Walder, J P; Denes, P; Mathez, H; Pangaud, P

    2001-01-01

    A wide dynamic range multi-gain transimpedance amplifier custom integrated circuit has been developed for the readout of avalanche photodiode and vacuum photodiode in the CMS electromagnetic calorimeter for LHC experiment. The 92 db input dynamic range is divided into four ranges of 12 bits each in order to provide 40 MHz analog sampled data to a 12 bits ADC. This concept, which has been integrated in rad-hard full complementary bipolar technology, will be described. Experimental results obtained in lab and under irradiation will be presented along with test strategy being used for mass production. 6 Refs.

  3. The control system for the CMS tracker front-end

    CERN Document Server

    Drouhin, F; Ljuslin, C; Maazouzi, C; Marchiero, A; Marinelli, N; Paillard, C; Siegrist, P; Tsirou, A L; Verdini, P G; Walsham, P; Zghiche, A

    2002-01-01

    The CMS Tracker uses complex, programmable embedded electronics for the readout of the Silicon sensors, for the control of the working point of the optical transmitters, for the phase adjustment of the 40 MHz LHC clock and for the monitoring of the voltages, currents and temperatures. In order to establish reliable, noise-free communication with the outside world the control chain has been designed to operate over a ribbon of optical fibers. The optical links, the Front End Controller board that carries their support electronics, the Clocking and Control Unit module receiving the signals over the high-speed link and fanning them out to the front- ends have recently become available. A multi-layered software architecture to handle these devices, and the front-ends, in a way transparent to the end-user, interfaced to an Oracle database for the retrieval of the parameters to be downloaded with the intent of building and operating a small-scale prototype of the control system for the CMS Tracker. The paper descri...

  4. Performance and Future Upgrades of the CMS Drift Tube Muon Detector

    CERN Document Server

    Redondo Ferrero, David Daniel

    2017-01-01

    A key component of the CMS (Compact Muon Solenoid) experiment is its muon system. The tracking and triggering of muons in the central part relies on Drift Tube (DT) chambers. The DT system keeps evolving in order to cope with long term operational challenges, as well as future constraints for rate reduction imposed by future increases of LHC luminosity, maintaining the highest possible efficiency. During the first long LHC shutdown (LS1) a significant number of improvements and upgrades started being implemented, in particular concerning the readout and trigger electronics. Ever since LS1, each LHC winter shutdown is used to install and test these new developments towards HL-LHC.Regarding the long term operation of the DT system, in order to cope with up to a factor 2 nominal LHC luminosity, several modifications will be required. The in-chamber local electronics will be modified to cope with the new environment. Also the second level of the readout system needs to be redesigned to minimize event processing ...

  5. Development of a new Silicon Tracker at CMS for Super-LHC

    CERN Document Server

    Pesaresi, Mark

    2010-01-01

    Tracking is an essential requirement for any high energy particle physics experiment. The Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC) employs an all silicon tracker, the largest of its kind, for the precise measurement of track momentum and vertex position. With approximately 10 million detector channels in the strip tracker alone, the analogue non-sparsified readout system has been designed to handle the large data volumes generated at the 100 kHz Level 1 (L1) trigger rate. Fluctuations in the event rate are controlled using buffers whose occupancies are constantly monitored to prevent overflows, otherwise causing loss of synchronisation and data. The status of the tracker is reported by the APV emulator (APVe), which has now been successfully commissioned within the silicon strip tracker readout system. The APVe plays a crucial role in the synchronisation of the tracker by deterministic calculation of the front end buffer occupancy and by monitoring the status of the Front End Dr...

  6. Design, simulation, fabrication, and preliminary tests of 3D CMS pixel detectors for the super-LHC

    Energy Technology Data Exchange (ETDEWEB)

    Koybasi, Ozhan; /Purdue U.; Bortoletto, Daniela; /Purdue U.; Hansen, Thor-Erik; /SINTEF, Oslo; Kok, Angela; /SINTEF, Oslo; Hansen, Trond Andreas; /SINTEF, Oslo; Lietaer, Nicolas; /SINTEF, Oslo; Jensen, Geir Uri; /SINTEF, Oslo; Summanwar, Anand; /SINTEF, Oslo; Bolla, Gino; /Purdue U.; Kwan, Simon Wing Lok; /Fermilab

    2010-01-01

    The Super-LHC upgrade puts strong demands on the radiation hardness of the innermost tracking detectors of the CMS, which cannot be fulfilled with any conventional planar detector design. The so-called 3D detector architectures, which feature columnar electrodes passing through the substrate thickness, are under investigation as a potential solution for the closest operation points to the beams, where the radiation fluence is estimated to reach 10{sup 16} n{sub eq}/cm{sup 2}. Two different 3D detector designs with CMS pixel readout electronics are being developed and evaluated for their advantages and drawbacks. The fabrication of full-3D active edge CMS pixel devices with p-type substrate has been successfully completed at SINTEF. In this paper, we study the expected post-irradiation behaviors of these devices with simulations and, after a brief description of their fabrication, we report the first leakage current measurement results as performed on wafer.

  7. The CMS Beam Halo Monitor at LHC implementation and first measurements

    CERN Document Server

    Tosi, Nicolo

    2017-01-01

    A Cherenkov based detector system has been installed at the Large Hadron Collider (LHC), in order to measure the Machine Induced Background (MIB) for the Compact Muon Solenoid (CMS) experiment.The system is composed of forty identical detector units formed by a cylindrical Quartz radiator directly coupled to a Photomultiplier. These units are installed at a radius of 1.8m and a distance of 20.6 m from the CMS interaction point.The fast and direction-sensitive signal allows to measure incoming MIB particles while suppressing the much more abundant collision products and albedo particles, which reach the detector at a different time and from a different direction.The system readout electronics is based on the QIE10 ASIC and a uTCA based back-end, and it allows a continuous online measurement of the background rate separately per each bunch.The detector has been installed in 2015 and is now fully commissioned. Measurements demonstrating the capability of detecting anomalous beam conditions will be presented.

  8. Channel control ASIC for the CMS hadron calorimeter front end readout module

    International Nuclear Information System (INIS)

    Ray Yarema et al.

    2002-01-01

    The Channel Control ASIC (CCA) is used along with a custom Charge Integrator and Encoder (QIE) ASIC to digitize signals from the hybrid photo diodes (HPDs) and photomultiplier tubes (PMTs) in the CMS hadron calorimeter. The CCA sits between the QIE and the data acquisition system. All digital signals to and from the QIE pass through the CCA chip. One CCA chip interfaces with two QIE channels. The CCA provides individually delayed clocks to each of the QIE chips in addition to various control signals. The QIE sends digitized PMT or HPD signals and time slice information to the CCA, which sends the data to the data acquisition system through an optical link

  9. Prospects for a precision timing upgrade of the CMS PbWO$_{4}$ crystal electromagnetic calorimeter for the HL-LHC

    CERN Document Server

    Marzocchi, Badder

    2017-01-01

    The upgrade of the Compact Muon Solenoid (CMS) crystal electromagnetic calorimeter (ECAL), which will operate at the High Luminosity Large Hadron Collider (HL-LHC), will achieve a timing resolution of around 30 ps for high energy photons and electrons. In this talk we will discuss the benefits of precision timing for the ECAL event reconstruction at HL-LHC. Simulation studies on the timing properties of PbWO crystals, as well as the impact of the photosensors and the readout electronics on the timing performance, will be presented. Test beam studies on the timing performance of PbWO$_{4}$ crystals with various photosensors and readout electronics will be shown.

  10. Prospects for a precision timing upgrade of the CMS PbWO crystal electromagnetic calorimeter for the HL-LHC

    Science.gov (United States)

    Massironi, A.

    2018-04-01

    The upgrade of the Compact Muon Solenoid (CMS) crystal electromagnetic calorimeter (ECAL), which will operate at the High Luminosity Large Hadron Collider (HL-LHC), will achieve a timing resolution of around 30 ps for high energy photons and electrons. In this talk we will discuss the benefits of precision timing for the ECAL event reconstruction at HL-LHC. Simulation studies focused on the timing properties of PbWO4 crystals, as well as the impact of the photosensors and the readout electronics on the timing performance, will be presented. Test beam studies intended to measure the timing performance of the PbWO4 crystals with different photosensors and readout electronics will be shown.

  11. Prospects for a precision timing upgrade of the CMS PbWO crystal electromagnetic calorimeter for the HL-LHC

    CERN Document Server

    Massironi, Andrea

    2017-01-01

    The upgrade of the Compact Muon Solenoid (CMS) crystal electromagnetic calorimeter (ECAL), which will operate at the High Luminosity Large Hadron Collider (HL-LHC), will achieve a timing resolution of around 30 ps for high energy photons and electrons. In this talk we will discuss the benefits of precision timing for the ECAL event reconstruction at HL-LHC. Simulation studies focused on the timing properties of PbWO$_4$ crystals, as well as the impact of the photosensors and the readout electronics on the timing performance, will be presented. Test beam studies intended to measure the timing performance of the PbWO$_4$ crystals with different photosensors and readout electronics will be shown.

  12. CMS Experiment Data Processing at RDMS CMS Tier 2 Centers

    CERN Document Server

    Gavrilov, V; Korenkov, V; Tikhonenko, E; Shmatov, S; Zhiltsov, V; Ilyin, V; Kodolova, O; Levchuk, L

    2012-01-01

    Russia and Dubna Member States (RDMS) CMS collaboration was founded in the year 1994 [1]. The RDMS CMS takes an active part in the Compact Muon Solenoid (CMS) Collaboration [2] at the Large Hadron Collider (LHC) [3] at CERN [4]. RDMS CMS Collaboration joins more than twenty institutes from Russia and Joint Institute for Nuclear Research (JINR) member states. RDMS scientists, engineers and technicians were actively participating in design, construction and commissioning of all CMS sub-detectors in forward regions. RDMS CMS physics program has been developed taking into account the essential role of these sub-detectors for the corresponding physical channels. RDMS scientists made large contribution for preparation of study QCD, Electroweak, Exotics, Heavy Ion and other physics at CMS. The overview of RDMS CMS physics tasks and RDMS CMS computing activities are presented in [5-11]. RDMS CMS computing support should satisfy the LHC data processing and analysis requirements at the running phase of the CMS experime...

  13. Experience in the Development of the CMS Inner Tracker Analog Optohybrid Circuits: Project, Qualification, Volume Production, Quality Assurance and Final Performance

    CERN Document Server

    Ricci, Daniel; Bilei, Gian Mario; Casinini, F; Postolache, Vasile

    2005-01-01

    The Tracker system of the Compact Muon Solenoid (CMS) Experiment, will employ approximately 40,000 analog fibre-optic data and control links. The optical readout system is responsible for converting and transmitting the electrical signals coming out from the front-end to the outside counting room. Concerning the inner part of the Tracker, about 3,600 Analog Optohybrid circuits are involved in this tasks. These circuits have been designed and successfully produced in Italy under the responsibility of INFN Perugia CMS group completing the volume production phase by February 2005. Environmental features, reliability and performances of these circuits have been extensively tested and qualified. This paper reviews the most relevant steps of the manufacturing and quality assurance process: from prototypes to mass-production for the final CMS use.

  14. Performance of the CMS precision electromagnetic calorimeter at LHC Run II and prospects for High-Luminosity LHC

    CERN Document Server

    Zhang, Zhicai

    2017-01-01

    Many physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high-resolution electron and photon energy measurements. Following the excellent performance achieved during LHC Run I at center-of-mass energies of 7 and 8 TeV, the CMS electromagnetic calorimeter (ECAL) is operating at the LHC with proton-proton collisions at 13 TeV center-of-mass energy. The instantaneous luminosity delivered by the LHC during Run II has achieved unprecedented levels. The average number of concurrent proton-proton collisions per bunch-crossing (pileup) has reached up to 40 interactions in 2016 and may increase further in 2017. These high pileup levels necessitate a retuning of the ECAL readout and trigger thresholds and reconstruction algorithms. In addition, the energy response of the detector must be precisely calibrated and monitored. We present new reconstruction algorithms and calibration strategies that were implemented to maintain the excellent performance of the CMS ECAL throughout Run...

  15. HGCAL A High-Granularity Calorimeter for the Endcaps of CMS at HL-LHC

    CERN Document Server

    Magnan, Anne-marie

    2016-01-01

    Calorimetry at the High Luminosity LHC (HL-LHC) faces two enormous challenges, particularly in the forward direction radiation tolerance and unprecedented in-time event pileup. To meet these challenges, the CMS experiment has decided to construct a High Granularity Calorimeter (HGCAL), featuring a previously unrealized transverse and longitudinal segmentation, for both electromagnetic and hadronic compartments. This will facilitate particle-flow-type calorimetry, where the fine structure of showers can be measured and used to enhance particle identification, energy resolution and pileup rejection. The majority of the HGCAL will be based on robust and cost-effective hexagonal silicon sensors with $\\simeq 1$\\,cm$^2$ or 0.5\\,cm$^2$ hexagonal cell size, with the final 5 interaction lengths of the hadronic compartment being based on highly segmented plastic scintillator with on-scintillator SiPM readout. We present an overview of the HGCAL project, including the motivation, engineering design, readout/trigger con...

  16. One Year of FOS Measurements in CMS Experiment at CERN

    Science.gov (United States)

    Szillási, Zoltán; Buontempo, Salvatore; Béni, Noémi; Breglio, Giovanni; Cusano, Andrea; Laudati, Armando; Giordano, Michele; Saccomanno, Andrea; Druzhkin, Dmitry; Tsirou, Andromachi

    Results are presented on the activity carried out by our research group, in collaboration with the SME Optosmart s.r.l. (an Italian spin-off company), on the application of Fiber Optic Sensor (FOS) techniques to monitor high-energy physics (HEP) detectors. Assuming that Fiber Bragg Grating sensors (FBGs) radiation hardness has been deeply studied for other field of application, we have applied the FBG technology to the HEP research domain. We present here the experimental evidences of the solid possibility to use such a class of sensors also in HEP detector very complex environmental side conditions. In particular we present more than one year data results of FBG measurements in the Compact Muon Solenoid (CMS) experiment set up at the CERN, where we have monitored temperatures (within CMS core) and strains in different locations by using FBG sensors during the detector operation with the Large Hadron Collider (LHC) collisions and high magnetic field. FOS data and FOS readout system stability and reliability is demonstrated, with continuous 24/24 h 7/7d data taking under severe and complex side conditions.

  17. Silicon Sensors for the Upgrades of the CMS Pixel Detector

    CERN Document Server

    Centis Vignali, Matteo; Schleper, Peter

    2015-01-01

    The Compact Muon Solenoid (CMS) is a general purpose detector at the Large Hadron Collider (LHC). The LHC luminosity is constantly increased through upgrades of the accel- erator and its injection chain. Two major upgrades will take place in the next years. The rst upgrade involves the LHC injector chain and allows the collider to achieve a luminosity of about 2 10 34 cm-2 s-1 A further upgrade of the LHC foreseen for 2025 will boost its luminosity to 5 10 34 cm-2 s1. As a consequence of the increased luminosity, the detectors need to be upgraded. In particular, the CMS pixel detector will undergo two upgrades in the next years. The rst upgrade (phase I) consists in the substitution of the current pixel detector in winter 2016/2017. The upgraded pixel detector will implement new readout elec- tronics that allow ecient data taking up to a luminosity of 2 10 34 cm-2s-1,twice as much as the LHC design luminosity. The modules that will constitute the upgraded detector are being produced at dierent institutes. Ham...

  18. 42 CFR 405.874 - Appeals of CMS or a CMS contractor.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Appeals of CMS or a CMS contractor. 405.874 Section... Part B Program § 405.874 Appeals of CMS or a CMS contractor. A CMS contractor's (that is, a carrier... supplier enrollment application. If CMS or a CMS contractor denies a provider's or supplier's enrollment...

  19. Validation of the Read Out Electronics for the CMS Muon Drift Chambers at Tests Beam in CERN/GIF; Validacion en el Test Beam del CERN/GIF de la electronica de Lectura de las Camaras de Muones del Experimento CMS

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, C.; Fouz, M. c.; Marin, J.; Oller, J. C.; Willmott, C.; Amigo, L. J.

    2002-07-01

    Part of the readout system for the CMS muon drift chambers has been tested in test beams at CERN/GIF. Read Out Board (ROB) and HPTD have been validated with signals from a real muon beam, with an structure and flux similar to LHC operating conditions and using one of the chambers produced in CIEMAT already located in the test beam area under normal gas and voltage conditions. (Author) 5 refs.

  20. Data analysis to evaluate the CPPF system in CMS trigger phase-I upgrade

    CERN Document Server

    CMS Collaboration

    2018-01-01

    The CMS Level-1 trigger upgrade system consists of several layers of electronics with a large number of homogeneous cards based on the Micro-TCA(uTCA) standard. The CPPF(Concentration Pre-Processing and Fan-out)system belongs to one of the electronic layers, covering the Muon RPC (Resistive plate chambers) Overlap and Endcap region, and provides preprocessing algorithm for track finding. It includes, in hardware, eight specially designed CPPF cards, one generic CMS card called AMC13, one commercial MCH card, and a Micro-TCA Shelf. Its functionality is realized with five firmware modules: TTC module, optical input module, optical output module, readout module, and a CORE module for cluster finding and transformation. In addition to the firmware functionality, online software is needed for controlling and monitoring each individual CPPF module and the whole CPPF system. This presentation will discuss the data analysis to evaluate the system.

  1. CMS Collaboration

    International Nuclear Information System (INIS)

    Faridah Mohammad Idris; Wan Ahmad Tajuddin Wan Abdullah; Zainol Abidin Ibrahim

    2013-01-01

    Full-text: CMS Collaboration is an international scientific collaboration located at European Organization for Nuclear Research (CERN), Switzerland, dedicated in carried out research on experimental particle physics. Consisting of 179 institutions from 41 countries from all around the word, CMS Collaboration host a general purpose detector for example the Compact Muon Solenoid (CMS) for members in CMS Collaboration to conduct experiment from the collision of two proton beams accelerated to a speed of 8 TeV in the LHC ring. In this paper, we described how the CMS detector is used by the scientist in CMS Collaboration to reconstruct the most basic building of matter. (author)

  2. Concepts and design of the CMS high granularity calorimeter Level-1 trigger

    CERN Document Server

    Sauvan, Jean-Baptiste

    2016-01-01

    The CMS experiment has chosen a novel high granularity calorimeter for the forward region as part of its planned upgrade for the high luminosity LHC. The calorimeter will have a fine segmentation in both the transverse and longitudinal directions and will be the first such calorimeter specifically optimised for particle flow reconstruction to operate at a colliding beam experiment. The high granularity results in around six million readout channels in total and so presents a significant challenge in terms of data manipulation and processing for the trigger; the trigger data volumes will be an order of magnitude above those currently handled at CMS. In addition, the high luminosity will result in an average of 140 to 200 interactions per bunch crossing, giving a huge background rate in the forward region that needs to be efficiently reduced by the trigger algorithms. Efficient data reduction and reconstruction algorithms making use of the fine segmentation of the detector have been simulated and evaluated. The...

  3. Status and future prospects of the Muon Drift Tubes system of CMS

    CERN Document Server

    Masetti, Gianni

    2016-01-01

    A key component of the CMS (Compact Muon Solenoid) experiment is its muon system. The tracking and triggering of muons in the central part relies on Drift Tube (DT) chambers. During the first Long Shutdown of LHC (LS1) a number of improvements and upgrades were implemented, in particular concerning the readout and trigger electronics. The increase of luminosity expected by LHC during phase 1 will impose several constraints for rate reduction while maintaining high efficiency in the CMS Level 1 trigger system.In order to exploit the muon detector redundancy, a new trigger system has been designed. The TwinMux system is the early layer of the muon barrel region that combines the primitives information from different subdetectors DT, Resistive Plate Chambers (RPC) and Outer Hadron Calorimeter (HO).Regarding the long term operation of the DT system, in order to cope with up to a factor 2 nominal LHC luminosity, several improvements will be implemented. The in-chamber local electronics will be modified to cope wi...

  4. CMS Detector Posters

    CERN Multimedia

    2016-01-01

    CMS Detector posters (produced in 2000): CMS installation CMS collaboration From the Big Bang to Stars LHC Magnetic Field Magnet System Trackering System Tracker Electronics Calorimetry Eletromagnetic Calorimeter Hadronic Calorimeter Muon System Muon Detectors Trigger and data aquisition (DAQ) ECAL posters (produced in 2010, FR & EN): CMS ECAL CMS ECAL-Supermodule cooling and mechatronics CMS ECAL-Supermodule assembly

  5. TRIGGER

    CERN Multimedia

    Wesley Smith

    Level-1 Trigger Hardware and Software The hardware of the trigger components has been mostly finished. The ECAL Endcap Trigger Concentrator Cards (TCC) are in production while Barrel TCC firmware has been upgraded, and the Trigger Primitives can now be stored by the Data Concentrator Card for readout by the DAQ. The Regional Calorimeter Trigger (RCT) system is complete, and the timing is being finalized. All 502 HCAL trigger links to RCT run without error. The HCAL muon trigger timing has been equalized with DT, RPC, CSC and ECAL. The hardware and firmware for the Global Calorimeter Trigger (GCT) jet triggers are being commissioned and data from these triggers is available for readout. The GCT energy sums from rings of trigger towers around the beam pipe beam have been changed to include two rings from both sides. The firmware for Drift Tube Track Finder, Barrel Sorter and Wedge Sorter has been upgraded, and the synchronization of the DT trigger is satisfactory. The CSC local trigger has operated flawlessly u...

  6. TRIGGER

    CERN Multimedia

    W. Smith

    Level-1 Trigger Hardware and Software The trigger system has been constantly in use in cosmic and commissioning data taking periods. During CRAFT running it delivered 300 million muon and calorimeter triggers to CMS. It has performed stably and reliably. During the abort gaps it has also provided laser and other calibration triggers. Timing issues, namely synchronization and latency issues, have been solved. About half of the Trigger Concentrator Cards for the ECAL Endcap (TCC-EE) are installed, and the firmware is being worked on. The production of the other half has started. The HCAL Trigger and Readout (HTR) card firmware has been updated, and new features such as fast parallel zero-suppression have been included. Repairs of drift tube (DT) trigger mini-crates, optical links and receivers of sector collectors are under way and have been completed on YB0. New firmware for the optical receivers of the theta links to the drift tube track finder is being installed. In parallel, tests with new eta track finde...

  7. CMS Connect

    Science.gov (United States)

    Balcas, J.; Bockelman, B.; Gardner, R., Jr.; Hurtado Anampa, K.; Jayatilaka, B.; Aftab Khan, F.; Lannon, K.; Larson, K.; Letts, J.; Marra Da Silva, J.; Mascheroni, M.; Mason, D.; Perez-Calero Yzquierdo, A.; Tiradani, A.

    2017-10-01

    The CMS experiment collects and analyzes large amounts of data coming from high energy particle collisions produced by the Large Hadron Collider (LHC) at CERN. This involves a huge amount of real and simulated data processing that needs to be handled in batch-oriented platforms. The CMS Global Pool of computing resources provide +100K dedicated CPU cores and another 50K to 100K CPU cores from opportunistic resources for these kind of tasks and even though production and event processing analysis workflows are already managed by existing tools, there is still a lack of support to submit final stage condor-like analysis jobs familiar to Tier-3 or local Computing Facilities users into these distributed resources in an integrated (with other CMS services) and friendly way. CMS Connect is a set of computing tools and services designed to augment existing services in the CMS Physics community focusing on these kind of condor analysis jobs. It is based on the CI-Connect platform developed by the Open Science Grid and uses the CMS GlideInWMS infrastructure to transparently plug CMS global grid resources into a virtual pool accessed via a single submission machine. This paper describes the specific developments and deployment of CMS Connect beyond the CI-Connect platform in order to integrate the service with CMS specific needs, including specific Site submission, accounting of jobs and automated reporting to standard CMS monitoring resources in an effortless way to their users.

  8. Validation of the Read Out Electronics for the CMS Muon Drift Chambers at Tests Beam in CERN/GIF

    CERN Document Server

    Fernández, C; Fouz-Iglesias, M C; Marin, J; Oller, J C; Willmott, C

    2002-01-01

    Part of the readout system for the CMS muon drift chambers has been tested in test beams at CERN/GIF. Read Out Board (ROB) and HPTD have been validated with signals from a real muon beam, with an structure and flux similar to LHC operating conditions and using one of the chambers produced in CIEMAT already located in the test beam area under normal gas and voltage conditions. (Author) 5 refs.

  9. Pixel Sensors with slim edges and small pitches for the CMS upgrades for HL-LHC

    CERN Document Server

    AUTHOR|(CDS)2084134; Bolla, Gino; Rivera, Ryan Allen; Uplegger, Lorenzo; Zoi, Irene

    2016-01-01

    Planar n-in-n silicon detectors with small pitches and slim edges are being investigated for the innermost layers of tracking devices for the foreseen upgrades of the LHC. Sensor prototypes compatible with the CMS readout, fabricated by Sintef, were tested in the laboratory and with a 120~GeV/c proton beam at the Fermilab test beam facility before and after irradiation with up to 2x10$^{15}$ n$_{eq}/$cm$^2$ fluence. Preliminary results of the data analysis are presented.

  10. CMS Factsheet

    CERN Multimedia

    Lapka, Marzena; Rao, Achintya

    2016-01-01

    CMS Factsheets: containing facts about the CMS collaboration and detector. Printed copies of the English version are available from the CMS Secretariat. Responsible for translations: English only - E.Gibney (updated 2015)

  11. The New CMS DAQ System for Run 2 of the LHC

    CERN Document Server

    AUTHOR|(CDS)2087644; Behrens, Ulf; Branson, James; Chaze, Olivier; Cittolin, Sergio; Darlea, Georgiana Lavinia; Deldicque, Christian; Dobson, Marc; Dupont, Aymeric; Erhan, Samim; Forrest, Andrew Kevin; Gigi, Dominique; Glege, Frank; Gomez Ceballos, Guillelmo; Gomez-Reino Garrido, Robert; Hegeman, Jeroen Guido; Holzner, Andre Georg; Masetti, Lorenzo; Meijers, Franciscus; Meschi, Emilio; Mommsen, Remigius; Morovic, Srecko; Vivian O'Dell; Orsini, Luciano; Paus, Christoph Maria Ernst; Petrucci, Andrea; Pieri, Marco; Racz, Attila; Sakulin, Hannes; Schwick, Christoph; Stieger, Benjamin Bastian; Sumorok, Konstanty; Veverka, Jan; Zejdl, Petr

    2015-01-01

    The data acquisition system (DAQ) of the CMS experiment at the CERN Large Hadron Collider assembles events at a rate of 100 kHz, transporting event data at an aggregate throughput of 100 GB/s to the high level trigger (HLT) farm. The HLT farm selects interesting events for storage and offline analysis at a rate of around 1 kHz. The DAQ system has been redesigned during the accelerator shutdown in 2013/14. The motivation is twofold Firstly, the current compute nodes, networking, and storage infrastructure will have reached the end of their lifetime by the time the LHC restarts. Secondly, in order to handle higher LHC luminosities and event pileup, a number of sub-detectors will be upgraded, increasing the number of readout channels and replacing the off-detector readout electronics with a micro-TCA implementation. The new DAQ architecture will take advantage of the latest developments in the computing industry. For data concentration, 10/40 Gb/s Ethernet technologies will be used, as well as an implementation...

  12. HGCAL: A High-Granularity Calorimeter for the Endcaps of CMS at HL-LHC

    Science.gov (United States)

    Ochando, Christophe; CMS Collaboration

    2017-11-01

    Calorimetry at the High Luminosity LHC (HL-LHC) faces two enormous challenges, particularly in the forward direction: radiation tolerance and unprecedented in-time event pileup. To meet these challenges, the CMS experiment has decided to construct a High Granularity Calorimeter (HGCAL), featuring a previously unrealized transverse and longitudinal segmentation, for both electromagnetic and hadronic compartments. This will facilitate particle-flow-type calorimetry, where the fine structure of showers can be measured and used to enhance particle identification, energy resolution and pileup rejection. The majority of the HGCAL will be based on robust and cost-effective hexagonal silicon sensors with about 1cm2 or 0.5cm2 hexagonal cell size, with the final 5 interaction lengths of the hadronic compartment being based on highly segmented plastic scintillator with on-scintillator SiPM readout. We present an overview of the HGCAL project, including the motivation, engineering design, readout concept and simulated performance.

  13. CMS-Wave

    Science.gov (United States)

    2015-10-30

    Coastal Inlets Research Program CMS -Wave CMS -Wave is a two-dimensional spectral wind-wave generation and transformation model that employs a forward...marching, finite-difference method to solve the wave action conservation equation. Capabilities of CMS -Wave include wave shoaling, refraction... CMS -Wave can be used in either on a half- or full-plane mode, with primary waves propagating from the seaward boundary toward shore. It can

  14. Radiation hardness of CMS pixel barrel modules

    International Nuclear Information System (INIS)

    Rohe, T.; Bean, A.; Erdmann, W.; Kaestli, H.-C.; Khalatyan, S.; Meier, B.; Radicci, V.; Sibille, J.

    2010-01-01

    Pixel detectors are used in the innermost part of the multi purpose experiments at the LHC and are therefore exposed to the highest fluences of ionising radiation, which in this part of the detectors consists mainly of charged pions. The radiation hardness of all detector components has been thoroughly tested up to the fluences expected at the LHC. In case of an LHC upgrade, the fluence will be much higher and it is not yet clear how long the present pixel modules will stay operative in such a harsh environment. The aim of this study was to establish such a limit as a benchmark for other possible detector concepts considered for the upgrade. As the sensors and the readout chip are the parts most sensitive to radiation damage, samples consisting of a small pixel sensor bump-bonded to a CMS-readout chip (PSI46V2.1) have been irradiated with positive 200 MeV pions at PSI up to 6x10 14 n eq /cm 2 and with 21 GeV protons at CERN up to 5x10 15 n eq /cm 2 . After irradiation the response of the system to beta particles from a 90 Sr source was measured to characterise the charge collection efficiency of the sensor. Radiation induced changes in the readout chip were also measured. The results show that the present pixel modules can be expected to be still operational after a fluence of 2.8x10 15 n eq /cm 2 . Samples irradiated up to 5x10 15 n eq /cm 2 still see the beta particles. However, further tests are needed to confirm whether a stable operation with high particle detection efficiency is possible after such a high fluence.

  15. arXiv Energy Reconstruction of Hadrons in highly granular combined ECAL and HCAL systems

    CERN Document Server

    Israeli, Yasmine

    2018-05-03

    This paper discusses the hadronic energy reconstruction of two combined electromagnetic and hadronic calorimeter systems using physics prototypes of the CALICE collaboration: the silicon-tungsten electromagnetic calorimeter (Si-W ECAL) and the scintillator-SiPM based analog hadron calorimeter (AHCAL); and the scintillator-tungsten electromagnetic calorimeter (ScECAL) and the AHCAL. These systems were operated in hadron beams at CERN and FNAL, permitting the study of the performance in combined ECAL and HCAL systems. Two techniques for the energy reconstruction are used, a standard reconstruction based on calibrated sub-detector energy sums, and one based on a software compensation algorithm making use of the local energy density information provided by the high granularity of the detectors. The software compensation-based algorithm improves the hadronic energy resolution by up to 30% compared to the standard reconstruction. The combined system data show comparable energy resolutions to the one achieved for da...

  16. Calibration and monitoring of a scintillator HCAL with SiPMs CALICE scintillator HCAL

    International Nuclear Information System (INIS)

    Lucaci-Timoce, Angela

    2009-01-01

    The operational experience with a highly-granular analogue hadronic calorimeter (AHCAL) consisting of 7608 individual scintillator tiles readout via Silicon-Photo-multipliers (SiPM) is presented. The calibration of each cell is based on minimum ionizing particle signals for which in general a muon beam is used. In addition, a correction for the non-linearity introduced by the finite number of pixels (1156) in the SiPM is applied. The aspects of temperature and voltage dependence of SiPM are addressed, and monitoring and calibration procedures are discussed. Such procedures are essential for the extrapolation of calibration factors over several days of data taking with the calorimeter. For this purpose a versatile UV-LED light distribution system was developed, capable of delivering light to all tiles with intensity from a few photo-electrons to the saturation of the SiPM. The procedures are tested using data collected with the AHCAL at the CERN SPS test beam.

  17. FILTRES: a 128 channels VLSI mixed front-end readout electronic development for microstrip detectors

    International Nuclear Information System (INIS)

    Anstotz, F.; Hu, Y.; Michel, J.; Sohler, J.L.; Lachartre, D.

    1998-01-01

    We present a VLSI digital-analog readout electronic chain for silicon microstrip detectors. The characteristics of this circuit have been optimized for the high resolution tracker of the CERN CMS experiment. This chip consists of 128 channels at 50 μm pitch. Each channel is composed by a charge amplifier, a CR-RC shaper, an analog memory, an analog processor, an output FIFO read out serially by a multiplexer. This chip has been processed in the radiation hard technology DMILL. This paper describes the architecture of the circuit and presents test results of the 128 channel full chain chip. (orig.)

  18. Commissioning of the CMS Hadron Forward Calorimeters Phase I Upgrade

    CERN Document Server

    Bilki, Burak

    2017-01-01

    The final phase of the CMS Hadron Forward Calorimeters Phase I upgrade was performed during the Extended Year End Technical Stop of 2016 and 2017. In the framework of the upgrade, the PMT boxes were reworked to implement two channel readout in order to exploit the benefits of the multi-anode PMTs in background tagging and signal recovery. The front-end electronics were also upgraded to QIE10-based electronics which implement larger dynamic range and a 6-bit TDC. Following this major upgrade, the Hadron Forward Calorimeters were commissioned for operation readiness in 2017. Here we describe the details and the components of the upgrade, and discuss the operational experience and results obtained during the upgrade and commissioning.

  19. Commissioning of the CMS Hadron Forward Calorimeters Phase I Upgrade

    Science.gov (United States)

    Bilki, B.; Onel, Y.

    2018-03-01

    The final phase of the CMS Hadron Forward Calorimeters Phase I Upgrade was performed during the Extended Year End Technical Stop of 2016-2017. In the framework of the upgrade, the PMT boxes were reworked to implement two channel readout in order to exploit the benefits of the multi-anode PMTs in background tagging and signal recovery. The front-end electronics were also upgraded to QIE10-based electronics which implement larger dynamic range and a 6-bit TDC. Following this major upgrade, the Hadron Forward Calorimeters were commissioned for operation readiness in 2017. Here we describe the details and the components of the upgrade, and discuss the operational experience and results obtained during the upgrade and commissioning.

  20. The upgrade of the CMS hadron calorimeter with silicon photomultipliers

    CERN Document Server

    Strobbe, N

    2017-01-01

    The upgrade of the hadron calorimeter of the CMS experiment at the CERN Large Hadron Collider is currently underway. The endcap sections will be upgraded in the winter of 2016–2017 and the barrel sections during the second LHC long shutdown in 2019. The existing photosensors will be replaced with about 16 000 new silicon photomultipliers (SiPMs), resulting in the first large installation of SiPMs in a radiation environment. All associated front-end electronics will also be upgraded. This paper discusses the motivation for the upgrade and provides a description 17 of the new system, including the SiPMs with associated control electronics and the front-end readout cards.

  1. Pixel sensors with slim edges and small pitches for the CMS upgrades for HL-LHC

    Energy Technology Data Exchange (ETDEWEB)

    Vernieri, Caterina, E-mail: cvernier@fnal.gov [Fermilab, Batavia, IL 60510 (United States); Bolla, Gino; Rivera, Ryan; Uplegger, Lorenzo [Fermilab, Batavia, IL 60510 (United States); Zoi, Irene [Fermilab, Batavia, IL 60510 (United States); University of Florence, Firenze, 50121 (Italy)

    2017-02-11

    Planar n-in-n silicon detectors with small pitches and slim edges are being investigated for the innermost layers of tracking devices for the foreseen upgrades of the LHC experiments. Sensor prototypes compatible with the CMS readout, fabricated by Sintef, were tested in the laboratory and with a 120 GeV/c proton beam at the Fermilab test beam facility before and after irradiation with up to 2×10{sup 15} n{sub eq}/cm{sup 2} fluence. Preliminary results of the data analysis are presented.

  2. SiPM based readout system for PbWO4 crystals

    Science.gov (United States)

    Berra, A.; Bolognini, D.; Bonfanti, S.; Bonvicini, V.; Lietti, D.; Penzo, A.; Prest, M.; Stoppani, L.; Vallazza, E.

    2013-08-01

    Silicon PhotoMultipliers (SiPMs) consist of a matrix of small passively quenched silicon avalanche photodiodes operated in limited Geiger-mode (GM-APDs) and read out in parallel from a common output node. Each pixel (with a typical size in the 20-100 μm range) gives the same current response when hit by a photon; the SiPM output signal is the sum of the signals of all the pixels, which depends on the light intensity. The main advantages of SiPMs with respect to photomultiplier tubes (PMTs) are essentially the small dimensions, the insensitivity to magnetic fields and a low bias voltage. This contribution presents the performance of a SiPM based readout system for crystal calorimeters developed in the framework of the FACTOR/TWICE collaboration. The SiPM used for the test is a new device produced by FBK-irst which consists in a matrix of four sensors embedded in the same silicon substrate, called QUAD. The SiPM has been coupled to a lead tungstate crystal, an early-prototype version of the crystals developed for the electromagnetic calorimeter of the CMS experiment. New tests are foreseen using a complete module consisting of nine crystals, each one readout by two QUADs.

  3. SiPM based readout system for PbWO4 crystals

    International Nuclear Information System (INIS)

    Berra, A.; Bolognini, D.; Bonfanti, S.; Bonvicini, V.; Lietti, D.; Penzo, A.; Prest, M.; Stoppani, L.; Vallazza, E.

    2013-01-01

    Silicon PhotoMultipliers (SiPMs) consist of a matrix of small passively quenched silicon avalanche photodiodes operated in limited Geiger-mode (GM-APDs) and read out in parallel from a common output node. Each pixel (with a typical size in the 20–100 μm range) gives the same current response when hit by a photon; the SiPM output signal is the sum of the signals of all the pixels, which depends on the light intensity. The main advantages of SiPMs with respect to photomultiplier tubes (PMTs) are essentially the small dimensions, the insensitivity to magnetic fields and a low bias voltage. This contribution presents the performance of a SiPM based readout system for crystal calorimeters developed in the framework of the FACTOR/TWICE collaboration. The SiPM used for the test is a new device produced by FBK-irst which consists in a matrix of four sensors embedded in the same silicon substrate, called QUAD. The SiPM has been coupled to a lead tungstate crystal, an early-prototype version of the crystals developed for the electromagnetic calorimeter of the CMS experiment. New tests are foreseen using a complete module consisting of nine crystals, each one readout by two QUADs

  4. Stand-alone Cosmic Muon Reconstruction Before Installation of the CMS Silicon Strip Tracker

    CERN Document Server

    Adam, W.; Dragicevic, M.; Friedl, M.; Fruhwirth, R.; Hansel, S.; Hrubec, J.; Krammer, M.; Oberegger, M.; Pernicka, M.; Schmid, S.; Stark, R.; Steininger, H.; Uhl, D.; Waltenberger, W.; Widl, E.; Van Mechelen, P.; Cardaci, M.; Beaumont, W.; de Langhe, E.; de Wolf, E.A.; Delmeire, E.; Hashemi, M.; Bouhali, O.; Charaf, O.; Clerbaux, B.; Dewulf, J.-P.; Elgammal, S.; Hammad, G.; de Lentdecker, G.; Marage, P.; Vander Velde, C.; Vanlaer, P.; Wickens, J.; Adler, V.; Devroede, O.; De Weirdt, S.; D'Hondt, J.; Goorens, R.; Heyninck, J.; Maes, J.; Mozer, Matthias Ulrich; Tavernier, S.; Van Lancker, L.; Van Mulders, P.; Villella, I.; Wastiels, C.; Bonnet, J.-L.; Bruno, G.; De Callatay, B.; Florins, B.; Giammanco, A.; Gregoire, G.; Keutgen, Th.; Kcira, D.; Lemaitre, V.; Michotte, D.; Militaru, O.; Piotrzkowski, K.; Quertermont, L.; Roberfroid, V.; Rouby, X.; Teyssier, D.; Daubie, E.; Anttila, E.; Czellar, S.; Engstrom, P.; Harkonen, J.; Karimaki, V.; Kostesmaa, J.; Kuronen, A.; Lampen, T.; Linden, T.; Luukka, P.-R.; Maenpaa, T.; Michal, S.; Tuominen, E.; Tuominiemi, J.; Ageron, M.; Baulieu, G.; Bonnevaux, A.; Boudoul, G.; Chabanat, E.; Chabert, E.; Chierici, R.; Contardo, D.; Della Negra, R.; Dupasquier, T.; Gelin, G.; Giraud, N.; Guillot, G.; Estre, N.; Haroutunian, R.; Lumb, N.; Perries, S.; Schirra, F.; Trocme, B.; Vanzetto, S.; Agram, J.-L.; Blaes, R.; Drouhin, F.; Ernenwein, J.-P.; Fontaine, J.-C.; Berst, J.-D.; Brom, J.-M.; Didierjean, F.; Goerlach, U.; Graehling, P.; Gross, L.; Hosselet, J.; Juillot, P.; Lounis, A.; Maazouzi, C.; Olivetto, C.; Strub, R.; Van Hove, P.; Anagnostou, G.; Brauer, R.; Esser, H.; Feld, L.; Karpinski, W.; Klein, K.; Kukulies, C.; Olzem, J.; Ostapchuk, A.; Pandoulas, D.; Pierschel, G.; Raupach, F.; Schael, S.; Schwering, G.; Sprenger, D.; Thomas, M.; Weber, M.; Wittmer, B.; Wlochal, M.; Beissel, F.; Bock, E.; Flugge, G.; Gillissen, C.; Hermanns, T.; Heydhausen, D.; Jahn, D.; Kaussen, G.; Linn, A.; Perchalla, L.; Poettgens, M.; Pooth, O.; Stahl, A.; Zoeller, M.H.; Buhmann, P.; Butz, E.; Flucke, G.; Hamdorf, R.; Hauk, J.; Klanner, R.; Pein, U.; Schleper, P.; Steinbruck, G.; Blum, P.; De Boer, W.; Dierlamm, A.; Dirkes, G.; Fahrer, M.; Frey, M.; Furgeri, A.; Hartmann, F.; Heier, S.; Hoffmann, K.-H.; Kaminski, J.; Ledermann, B.; Liamsuwan, T.; Muller, S.; Muller, Th.; Schilling, F.-P.; Simonis, H.-J.; Steck, P.; Zhukov, V.; Cariola, P.; De Robertis, G.; Ferorelli, R.; Fiore, L.; Preda, M.; Sala, G.; Silvestris, L.; Tempesta, P.; Zito, G.; Creanza, D.; De Filippis, N.; De Palma, M.; Giordano, D.; Maggi, G.; Manna, N.; My, S.; Selvaggi, G.; Albergo, S.; Chiorboli, M.; Costa, S.; Galanti, M.; Giudice, N.; Guardone, N.; Noto, F.; Potenza, R.; Saizu, M.A.; Sparti, V.; Sutera, C.; Tricomi, A.; Tuve, C.; Brianzi, M.; Civinini, C.; Maletta, F.; Manolescu, F.; Meschini, M.; Paoletti, S.; Sguazzoni, G.; Broccolo, B.; Ciulli, V.; D'Alessandro, R.; Focardi, E.; Frosali, S.; Genta, C.; Landi, G.; Lenzi, P.; Macchiolo, A.; Magini, N.; Parrini, G.; Scarlini, E.; Cerati, G.; Azzi, P.; Bacchetta, N.; Candelori, A.; Dorigo, T.; Kaminsky, A.; Karaevski, S.; Khomenkov, V.; Reznikov, S.; Tessaro, M.; Bisello, D.; De Mattia, M.; Giubilato, P.; Loreti, M.; Mattiazzo, S.; Nigro, M.; Paccagnella, A.; Pantano, D.; Pozzobon, N.; Tosi, M.; Bilei, G.M.; Checcucci, B.; Fano, L.; Servoli, L.; Ambroglini, F.; Babucci, E.; Benedetti, D.; Biasini, M.; Caponeri, B.; Covarelli, R.; Giorgi, M.; Lariccia, P.; Mantovani, G.; Marcantonini, M.; Postolache, V.; Santocchia, A.; Spiga, D.; Bagliesi, G.; Balestri, G.; Berretta, L.; Bianucci, S.; Boccali, T.; Bosi, F.; Bracci, F.; Castaldi, R.; Ceccanti, M.; Cecchi, R.; Cerri, C.; Cucoanes, A .S.; Dell'Orso, R.; Dobur, D.; Dutta, S.; Giassi, A.; Giusti, S.; Kartashov, D.; Kraan, A.; Lomtadze, T.; Lungu, G.A.; Magazzu, G.; Mammini, P.; Mariani, F.; Martinelli, G.; Moggi, A.; Palla, F.; Palmonari, F.; Petragnani, G.; Profeti, A.; Raffaelli, F.; Rizzi, D.; Sanguinetti, G.; Sarkar, S.; Sentenac, D.; Serban, A.T.; Slav, A.; Soldani, A.; Spagnolo, P.; Tenchini, R.; Tolaini, S.; Venturi, A.; Verdini, P.G.; Vos, M.; Zaccarelli, L.; Avanzini, C.; Basti, A.; Benucci, L.; Bocci, A.; Cazzola, U.; Fiori, F.; Linari, S.; Massa, M.; Messineo, A.; Segneri, G.; Tonelli, G.; Azzurri, P.; Bernardini, J.; Borrello, L.; Calzolari, F.; Foa, L.; Gennai, S.; Ligabue, F.; Petrucciani, G.; Rizzi, A.; Yang, Z.; Benotto, F.; Demaria, N.; Dumitrache, F.; Farano, R.; Borgia, M.A.; Castello, R.; Costa, M.; Migliore, E.; Romero, A.; Abbaneo, D.; Abbas, M.; Ahmed, I.; Akhtar, I.; Albert, E.; Bloch, C.; Breuker, H.; Butt, S.; Buchmuller, O.; Cattai, A.; Delaere, C.; Delattre, M.; Edera, L.M.; Engstrom, P.; Eppard, M.; Gateau, M.; Gill, K.; Giolo-Nicollerat, A.-S.; Grabit, R.; Honma, A.; Huhtinen, M.; Kloukinas, K.; Kortesmaa, J.; Kottelat, L.J.; Kuronen, A.; Leonardo, N.; Ljuslin, C.; Mannelli, M.; Masetti, L.; Marchioro, A.; Mersi, S.; Michal, S.; Mirabito, L.; Muffat-Joly, J.; Onnela, A.; Paillard, C.; Pal, I.; Pernot, J.F.; Petagna, P.; Petit, P.; Piccut, C.; Pioppi, M.; Postema, H.; Ranieri, R.; Ricci, D.; Rolandi, G.; Ronga, F.; Sigaud, C.; Syed, A.; Siegrist, P.; Tropea, P.; Troska, J.; Tsirou, A.; Vander Donckt, M.; Vasey, F.; Alagoz, E.; Amsler, Claude; Chiochia, V.; Regenfus, Christian; Robmann, P.; Rochet, J.; Rommerskirchen, T.; Schmidt, A.; Steiner, S.; Wilke, L.; Church, I.; Cole, J.; Coughlan, J.; Gay, A.; Taghavi, S.; Tomalin, I.; Bainbridge, R.; Cripps, N.; Fulcher, J.; Hall, G.; Noy, M.; Pesaresi, M.; Radicci, V.; Raymond, D.M.; Sharp, P.; Stoye, M.; Wingham, M.; Zorba, O.; Goitom, I.; Hobson, P.R.; Reid, I.; Teodorescu, L.; Hanson, G.; Jeng, G.-Y.; Liu, H.; Pasztor, G.; Satpathy, A.; Stringer, R.; Mangano, B.; Affolder, K.; Affolder, T.; Allen, A.; Barge, D.; Burke, S.; Callahan, D.; Campagnari, C.; Crook, A.; D'Alfonso, M.; Dietch, J.; Garberson, Jeffrey Ford; Hale, D.; Incandela, H.; Incandela, J.; Jaditz, S.; Kalavase, P.; Kreyer, S.; Kyre, S.; Lamb, J.; Mc Guinness, C.; Mills, C.; Nguyen, H.; Nikolic, M.; Lowette, S.; Rebassoo, F.; Ribnik, J.; Richman, J.; Rubinstein, N.; Sanhueza, S.; Shah, Y.; Simms, L.; Staszak, D.; Stoner, J.; Stuart, D.; Swain, S.; Vlimant, J.-R.; White, D.; Ulmer, K.A.; Wagner, S.R.; Bagby, L.; Bhat, P.C.; Burkett, K.; Cihangir, S.; Gutsche, O.; Jensen, H.; Johnson, M.; Luzhetskiy, N.; Mason, D.; Miao, T.; Moccia, S.; Noeding, C.; Ronzhin, A.; Skup, E.; Spalding, W.J.; Spiegel, L.; Tkaczyk, S.; Yumiceva, F.; Zatserklyaniy, A.; Zerev, E.; Anghel, I.; Bazterra, V.E.; Gerber, C.E.; Khalatian, S.; Shabalina, E.; Baringer, Philip S.; Bean, A.; Chen, J.; Hinchey, C.; Martin, C.; Moulik, T.; Robinson, R.; Gritsan, A.V.; Lae, C.K.; Tran, N.V.; Everaerts, P.; Hahn, K.A.; Harris, P.; Nahn, S.; Rudolph, M.; Sung, K.; Betchart, B.; Demina, R.; Gotra, Y.; Korjenevski, S.; Miner, D.; Orbaker, D.; Christofek, L.; Hooper, R.; Landsberg, G.; Nguyen, D.; Narain, M.; Speer, T.; Tsang, K.V.

    2009-01-01

    The subsystems of the CMS silicon strip tracker were integrated and commissioned at the Tracker Integration Facility (TIF) in the period from November 2006 to July 2007. As part of the commissioning, large samples of cosmic ray data were recorded under various running conditions in the absence of a magnetic field. Cosmic rays detected by scintillation counters were used to trigger the readout of up to 15% of the final silicon strip detector, and over 4.7 million events were recorded. This document describes the cosmic track reconstruction and presents results on the performance of track and hit reconstruction as from dedicated analyses.

  5. Performance of the Pixel Luminosity Telescope for Luminosity Measurement at CMS during Run2

    CERN Document Server

    Lujan, Paul Joseph

    2017-01-01

    The Pixel Luminosity Telescope (PLT) is a dedicated system for luminosity measurement at the CMS experiment using silicon pixel sensors arranged into telescopes, each consisting of three sensor planes. It was installed in CMS at the beginning of 2015 and has been providing online and offline luminosity measurements throughout Run 2 of the LHC. The online bunch-by-bunch luminosity measurement employs the fast-or capability of the pixel readout chip to identify events where a hit is registered in all three sensors in a telescope, corresponding primarily to tracks originating from the interaction point. In addition, the full pixel information is read out at a lower rate, allowing for the calculation of corrections to the online luminosity from effects such as the miscounting of tracks not originating from the interaction point and detector efficiency. This paper presents results from the 2016 running of the PLT, including commissioning and operational history, luminosity calibration using Van der Meer scans, and...

  6. CMS General Poster 2009 : to raise awareness of CMS, the CMS detector, its parts and people

    CERN Multimedia

    CMS outreach

    2012-01-01

    A poster which is identical to the two inside pages of the CMS brochure. The poster contains an image of a cross section of the CMS detector, explanation of detector parts, the aims of the CMS experiment and numbers of scientists and institutions associated with the experiment.

  7. The CMS Trigger Supervisor: Control and Hardware Monitoring System of the CMS Level-1 Trigger at CERN

    CERN Document Server

    Ildefons Magrans de Abril

    2008-01-01

    The experiments CMS (Compact Muon Solenoid) and ATLAS (A Toroidal LHC ApparatuS) at the LargeHadron Collider (LHC) are the greatest exponents of the rising complexity in High Energy Physics (HEP) datahandling instrumentation. Tens of millions of readout channels, tens of thousands of hardware boards and thesame order of connections are figures of merit. However, the hardware volume is not the only complexitydimension, the unprecedented large number of research institutes and scientists that form the internationalcollaborations, and the long design, development, commissioning and operational phases are additional factorsthat must be taken into account.The Level-1 (L1) trigger decision loop is an excellent example of these difficulties. This system is based on apipelined logic destined to analyze without deadtime the data from each LHC bunch crossing occurring every25_ns, using special coarsely segmented trigger data from the detectors. The L1 trigger is responsible forreducing the rate of accepted crossings to...

  8. Development and evaluation of test stations for the quality assurance of the silicon micro-strip detector modules for the CMS experiment

    International Nuclear Information System (INIS)

    Poettgens, M.

    2007-01-01

    CMS (Compact Muon Solenoid) is one of four large-scale detectors which will be operated at the LHC (Large Hadron Collider) at the European Laboratory for Particle Physics (CERN). For the search for new physics the reconstruction of the collision products and their properties is essential. In the innermost part of the CMS detector the traces of ionizing particles are measured utilizing a silicon tracker. A large fraction of this detector is equipped with silicon micro-strip modules which provide a precise space resolution in 1-dimension. A module consists of a sensor for detection of particles, the corresponding read-out electronics (hybrid) and a mechanical support structure. Since the 15,148 modules, which will be installed in the silicon micro-strip detector, have a total sensitive surface area of about 198 m 2 , the inner tracker of CMS is the largest silicon tracking detector, which has ever been built. While the sensors and hybrids are produced in industry, the construction of the modules and the control of the quality is done by the members of the 21 participating institutes. Since the access to the silicon micro-strip tracker will be very limited after the installation in the CMS detector the installed modules must be of high quality. For this reason the modules are thoroughly tested and the test results are uploaded to a central database. By the development of a read-out system and the corresponding software the III. Physikalisches Institut made an important contribution for the electrical and functional quality control of hybrids and modules. The read-out system provides all features for the operation and test of hybrids and modules and stands out due to high reliability and simple handling. Because a very user-friedly and highly automated software it became the official test tool and was integrated in various test stands. The test stands, in which the read-out system is integrated in, are described and the tests which are implemented in the corresponding

  9. Development and evaluation of test stations for the quality assurance of the silicon micro-strip detector modules for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Poettgens, M.

    2007-11-22

    CMS (Compact Muon Solenoid) is one of four large-scale detectors which will be operated at the LHC (Large Hadron Collider) at the European Laboratory for Particle Physics (CERN). For the search for new physics the reconstruction of the collision products and their properties is essential. In the innermost part of the CMS detector the traces of ionizing particles are measured utilizing a silicon tracker. A large fraction of this detector is equipped with silicon micro-strip modules which provide a precise space resolution in 1-dimension. A module consists of a sensor for detection of particles, the corresponding read-out electronics (hybrid) and a mechanical support structure. Since the 15,148 modules, which will be installed in the silicon micro-strip detector, have a total sensitive surface area of about 198 m{sup 2}, the inner tracker of CMS is the largest silicon tracking detector, which has ever been built. While the sensors and hybrids are produced in industry, the construction of the modules and the control of the quality is done by the members of the 21 participating institutes. Since the access to the silicon micro-strip tracker will be very limited after the installation in the CMS detector the installed modules must be of high quality. For this reason the modules are thoroughly tested and the test results are uploaded to a central database. By the development of a read-out system and the corresponding software the III. Physikalisches Institut made an important contribution for the electrical and functional quality control of hybrids and modules. The read-out system provides all features for the operation and test of hybrids and modules and stands out due to high reliability and simple handling. Because a very user-friedly and highly automated software it became the official test tool and was integrated in various test stands. The test stands, in which the read-out system is integrated in, are described and the tests which are implemented in the

  10. Development and implementation of quality control strategies for CMS silicon strip tracker modules

    International Nuclear Information System (INIS)

    Dirkes, G.

    2003-01-01

    The CMS group in Karlsruhe is involved in the construction of the silicon trackers end-caps and will produce and qualify the 1 600 modules of ring 5. Therefore automatic test systems for module qualification are developed and test strategies are worked out. For the electrical tests a complete readout system is developed, based on readout modules available within the collaboration and extended by home build modules. These are based on a modular approach with less complex functional units attached to a motherboard and includes key functionalities like clock and trigger generation and their distribution, high and low voltage supply and test signal generation usable with lasers or infrared LEDs. The motherboard is connected to a standard PC, hosting a fast ADC, interface cards to the motherboard and the front-end electronics. Already during the R and D phase of this readout system, first prototype tests were performed and some weak points of the design were uncovered, resulting in changes of the electronics design of the front end hybrids. Two test stations are built. The first one focuses on a fast functionality test, which includes an active thermal cycle with readout at -10 C performed for each individual module. The other test station focuses on debugging and repair requirements. It disposes of sufficient space for a flexible use of the system, including the possibility of additional test options with lasers, radioactive sources, probes and LEDs. For quality control measurements at module level it turned out, that LEDs are of good use: Besides external signal generation by running them in a pulsed way, they can be used for constant illumination of sensors, inducing an artificial leakage current. This led to the discovery of gain losses of complete readout chips induced by shorted AC coupling capacitances of several readout channels, which are called pinholes. Therefore pinholes must be unbonded from the front end preamplifier, which requires faultless

  11. The 'KATOD-1' strip readout ASIC for cathode strip chamber

    International Nuclear Information System (INIS)

    Golutvin, I.A.; Gorbunov, N.V.; Karzhavin, V.Yu.; Khabarov, V.S.; Movchan, S.A.; Smolin, D.A.; Dvornikov, O.V.; Shumejko, N.M.; Chekhovskij, V.A.

    2001-01-01

    The 'KATOD-1', a 16-channels readout ASIC, has been designed to perform tests of P3 and P4 full-scale prototypes of the cathode strip chamber for the ME1/1 forward muon station of the Compact Muon Solenoid (CMS) experiment. The ASIC channel consists of two charge-sensitive preamplifiers, a three-stage shaper with cancellation, and an output driver. The ASIC is instrumented with control of gain, in the range of (-4.2 : +5.0) mV/fC, and control of output pulse-shape. The equivalent input noise is equal to 2400 e with the slope of 12 e/pF for detector capacity up to 200 pF. The peaking time is 100 ns for the chamber signal. The ASIC has been produced by a microwave Bi-jFET technology

  12. A new Slow Control and Run Initialization Byte-wise Environment (SCRIBE) for the quality control of mass-produced CMS GEM detectors

    CERN Document Server

    Colafranceschi, Stefano

    2016-01-01

    The CMS collaboration aims at improving the muon trigger and tracking performance at the HL-LHC by installing new Gas Electron Multiplier (GEM) detectors in the endcaps of the CMS experiment. Construction and commissioning of GEM detectors for the first muon endcap stations is ramping up in several laboratories using common quality control protocols. The SCRIBE framework is a scalable and cross-platform web-based application for the RD51 Scalable Readout System (SRS) that controls data acquisition and analyzes data in near real time. It has been developed mainly to simplify and standardize measurements of the GEM detector response uniformities with x-rays across all production sites. SCRIBE works with zero suppression of raw SRS pulse height data. This has increased acquisition rates to 5 kHz for a CMS GEM detector with 3072 strips and allows strip-by-strip response comparisons with a few hours of data taking. SCRIBE also manages parallel data reconstruction to provide near real-time feedback on the detector ...

  13. Data acquisition software for the CMS strip tracker

    International Nuclear Information System (INIS)

    Bainbridge, R; Cripps, N; Fulcher, J; Radicci, V; Wingham, M; Baulieu, G; Bel, S; Delaere, C; Drouhin, F; Gill, K; Mirabito, L; Cole, J; Jesus, A C A; Giassi, A; Giordano, D; Gross, L; Hahn, K; Mersi, S; Nikolic, M; Tkaczyk, S

    2008-01-01

    The CMS silicon strip tracker, providing a sensitive area of approximately 200 m 2 and comprising 10 million readout channels, has recently been completed at the tracker integration facility at CERN. The strip tracker community is currently working to develop and integrate the online and offline software frameworks, known as XDAQ and CMSSW respectively, for the purposes of data acquisition and detector commissioning and monitoring. Recent developments have seen the integration of many new services and tools within the online data acquisition system, such as event building, online distributed analysis, an online monitoring framework, and data storage management. We review the various software components that comprise the strip tracker data acquisition system, the software architectures used for stand-alone and global data-taking modes. Our experiences in commissioning and operating one of the largest ever silicon micro-strip tracking systems are also reviewed

  14. SiPM based readout system for PbWO{sub 4} crystals

    Energy Technology Data Exchange (ETDEWEB)

    Berra, A., E-mail: alessandro.berra@gmail.com [Università degli Studi dell' Insubria e INFN sezione di Milano Bicocca, Via Valleggio, 11-22100 Como (Italy); Bolognini, D.; Bonfanti, S. [Università degli Studi dell' Insubria e INFN sezione di Milano Bicocca, Via Valleggio, 11-22100 Como (Italy); Bonvicini, V. [INFN sezione di Trieste (Italy); Lietti, D. [Università degli Studi dell' Insubria e INFN sezione di Milano Bicocca, Via Valleggio, 11-22100 Como (Italy); Penzo, A. [INFN sezione di Trieste (Italy); Prest, M.; Stoppani, L. [Università degli Studi dell' Insubria e INFN sezione di Milano Bicocca, Via Valleggio, 11-22100 Como (Italy); Vallazza, E. [INFN sezione di Trieste (Italy)

    2013-08-01

    Silicon PhotoMultipliers (SiPMs) consist of a matrix of small passively quenched silicon avalanche photodiodes operated in limited Geiger-mode (GM-APDs) and read out in parallel from a common output node. Each pixel (with a typical size in the 20–100 μm range) gives the same current response when hit by a photon; the SiPM output signal is the sum of the signals of all the pixels, which depends on the light intensity. The main advantages of SiPMs with respect to photomultiplier tubes (PMTs) are essentially the small dimensions, the insensitivity to magnetic fields and a low bias voltage. This contribution presents the performance of a SiPM based readout system for crystal calorimeters developed in the framework of the FACTOR/TWICE collaboration. The SiPM used for the test is a new device produced by FBK-irst which consists in a matrix of four sensors embedded in the same silicon substrate, called QUAD. The SiPM has been coupled to a lead tungstate crystal, an early-prototype version of the crystals developed for the electromagnetic calorimeter of the CMS experiment. New tests are foreseen using a complete module consisting of nine crystals, each one readout by two QUADs.

  15. Testbeam and laboratory test results of irradiated 3D CMS pixel detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bubna, Mayur [Purdue University, Department of Physics, West Lafayette, IN 47907-1396 (United States); Purdue University, School of Electrical and Computer Engineering, West Lafayette, IN 47907-1396 (United States); Alagoz, Enver, E-mail: enver.alagoz@cern.ch [Purdue University, Department of Physics, West Lafayette, IN 47907-1396 (United States); Cervantes, Mayra; Krzywda, Alex; Arndt, Kirk [Purdue University, Department of Physics, West Lafayette, IN 47907-1396 (United States); Obertino, Margherita; Solano, Ada [Istituto Nazionale di Fisica Nucleare, Sezione di Torino, 10125 Torino (Italy); Dalla Betta, Gian-Franco [INFN Padova (Gruppo Collegato di Trento) (Italy); Dipartimento di Ingegneria e Scienzadella Informazione, Universitá di Trento, I-38123 Povo di Trento (Italy); Menace, Dario; Moroni, Luigi [Istituto Nazionale di Fisica Nucleare, Sezione di Milano Bicocca (Italy); Universitá degli Studi di Milano Bicocca, 20126 Milano (Italy); Uplegger, Lorenzo; Rivera, Ryan [Fermi National Accelerator Laboratory, Batavia, IL 60510-0500 (United States); Osipenkov, Ilya [Texas A and M University, Department of Physics, College Station, TX 77843-4242 (United States); Andresen, Jeff [Fermi National Accelerator Laboratory, Batavia, IL 60510-0500 (United States); Bolla, Gino; Bortoletto, Daniela [Purdue University, Department of Physics, West Lafayette, IN 47907-1396 (United States); Boscardin, Maurizio [Centro per i Materiali e i Microsistemi Fondazione Bruno Kessler (FBK), Trento, I-38123 Povo di Trento (Italy); Marie Brom, Jean [Strasbourg IPHC, Institut Pluriedisciplinaire Hubert Curien, F-67037 Strasbourg Cedex (France); Brosius, Richard [State University of New York at Buffalo (SUNY), Department of Physics, Buffalo, NY 14260-1500 (United States); Chramowicz, John [Fermi National Accelerator Laboratory, Batavia, IL 60510-0500 (United States); and others

    2013-12-21

    The CMS silicon pixel detector is the tracking device closest to the LHC p–p collisions, which precisely reconstructs the charged particle trajectories. The planar technology used in the current innermost layer of the pixel detector will reach the design limit for radiation hardness at the end of Phase I upgrade and will need to be replaced before the Phase II upgrade in 2020. Due to its unprecedented performance in harsh radiation environments, 3D silicon technology is under consideration as a possible replacement of planar technology for the High Luminosity-LHC or HL-LHC. 3D silicon detectors are fabricated by the Deep Reactive-Ion-Etching (DRIE) technique which allows p- and n-type electrodes to be processed through the silicon substrate as opposed to being implanted through the silicon surface. The 3D CMS pixel devices presented in this paper were processed at FBK. They were bump bonded to the current CMS pixel readout chip, tested in the laboratory, and testbeams carried out at FNAL with the proton beam of 120 GeV/c. In this paper we present the laboratory and beam test results for the irradiated 3D CMS pixel devices. -- Highlights: •Pre-irradiation and post-irradiation electrical properties of 3D sensors and 3D diodes from various FBK production batches were measured and analyzed. •I–T measurements of gamma irradiated diodes were analyzed to understand leakage current generation mechanism in 3D diodes. •Laboratory measurements: signal to noise ratio and charge collection efficiency of 3D sensors before and after irradiation. •Testbeam measurements: pre- and post-irradiation pixel cell efficiency and position resolution of 3D sensors.

  16. Readout Architecture for Hybrid Pixel Readout Chips

    CERN Document Server

    AUTHOR|(SzGeCERN)694170; Westerlund, Tomi; Wyllie, Ken

    The original contribution of this thesis to knowledge are novel digital readout architectures for hybrid pixel readout chips. The thesis presents asynchronous bus-based architecture, a data-node based column architecture and a network-based pixel matrix architecture for data transportation. It is shown that the data-node architecture achieves readout efficiency 99 % with half the output rate as a bus-based system. The network-based solution avoids ``broken'' columns due to some manufacturing errors, and it distributes internal data traffic more evenly across the pixel matrix than column-based architectures. An improvement of $>$ 10 % to the efficiency is achieved with uniform and non-uniform hit occupancies. Architectural design has been done using transaction level modeling ($TLM$) and sequential high-level design techniques for reducing the design and simulation time. It has been possible to simulate tens of column and full chip architectures using the high-level techniques. A decrease of $>$ 10 in run-time...

  17. CMS Fast Facts

    Data.gov (United States)

    U.S. Department of Health & Human Services — CMS has developed a new quick reference statistical summary on annual CMS program and financial data. CMS Fast Facts includes summary information on total program...

  18. Calibration and performance test of the Very-Front-End electronics for the CMS electromagnetic calorimeter

    International Nuclear Information System (INIS)

    Blaha, J.

    2008-05-01

    A Very-Front-End (VFE) card is an important part of the on-detector read-out electronics of the CMS (Compact Muon Solenoid) electromagnetic calorimeter that is made of ∼ 76.000 radiation hard scintillating crystals PbWO 4 and operates on the Large Hadron Collider (LHC) at CERN. Almost 16.000 VFE cards that shape, amplify and digitize incoming signals from photodetectors generated by interacting particles. Since any maintenance of any part of the calorimeter is not possible during the 10-year lifetime of the experiment, the extensive screening program was employed throughout the whole manufacture process. As a part of readout electronics quality assurance program, the systems for burn-in and precise calibration of the VFE boards were developed and successfully used at IPN Lyon. In addition to functionality tests, all relevant electrical properties of each card were measured and analyzed in detail to obtain their full characterization and to build a database with all required parameters which will serve for the initial calibration of the whole calorimeter. In order to evaluate the calorimeter performance and also to deliver the most precise calibration constants, several fully equipped super-modules were extensively studied and calibrated during the test beam campaigns at CERN. As an important part of these tests, accurate studies of the electronics noise and relative gains, which are needed for measurement in high energy range, were carried out to optimize amplitude reconstruction procedure and thus improve the precision of the calorimeter energy determination. The heart of the thesis consists of the calibration of all VFE boards, including optimization of the laboratory calibration system and precise analysis of measured values to delivered desired calibration constants. The second half of the thesis is focused on the accurate evaluation and optimization of the read-out electronics in real data taking conditions. The results obtained in the laboratory at IPN Lyon

  19. Construction of the CMS Tracker End-Caps and an Impact Study on Defects

    CERN Document Server

    Linn, Alexander

    2008-01-01

    The CMS experiment at the LHC accelerator at the research center CERN close to Geneva will study proton proton collisions at up to now unprecedented centre of mass energies from the year 2008 on. To discover theoretically predicted elementary particles, CMS was equipped with the largest silicon tracker so far with a sensitive area of 198m2. Partitioned into more than 15.000 silicon strip modules, the construction and test of the tracker was a huge challenge for the involved institutes. The III. Physikalisches Institut B of the RWTH Aachen had a leading role in the construction and test of substructures, so called petals, for the end caps of the tracker. The petals were assembled in a clean room and underwent first basic tests to ensure the general operationability of each component. Failures detected during the assembly are described and improvements of the silicon strip modules are discussed. After the assembly the petals underwent a cold test for several days. For the first time all readout components of th...

  20. CMS Wallet Card

    Data.gov (United States)

    U.S. Department of Health & Human Services — The CMS Wallet Card is a quick reference statistical summary on annual CMS program and financial data. The CMS Wallet Card is available for each year from 2004...

  1. The TOTEM DAQ based on the Scalable Readout System (SRS)

    Science.gov (United States)

    Quinto, Michele; Cafagna, Francesco S.; Fiergolski, Adrian; Radicioni, Emilio

    2018-02-01

    The TOTEM (TOTal cross section, Elastic scattering and diffraction dissociation Measurement at the LHC) experiment at LHC, has been designed to measure the total proton-proton cross-section and study the elastic and diffractive scattering at the LHC energies. In order to cope with the increased machine luminosity and the higher statistic required by the extension of the TOTEM physics program, approved for the LHC's Run Two phase, the previous VME based data acquisition system has been replaced with a new one based on the Scalable Readout System. The system features an aggregated data throughput of 2GB / s towards the online storage system. This makes it possible to sustain a maximum trigger rate of ˜ 24kHz, to be compared with the 1KHz rate of the previous system. The trigger rate is further improved by implementing zero-suppression and second-level hardware algorithms in the Scalable Readout System. The new system fulfils the requirements for an increased efficiency, providing higher bandwidth, and increasing the purity of the data recorded. Moreover full compatibility has been guaranteed with the legacy front-end hardware, as well as with the DAQ interface of the CMS experiment and with the LHC's Timing, Trigger and Control distribution system. In this contribution we describe in detail the architecture of full system and its performance measured during the commissioning phase at the LHC Interaction Point.

  2. Design of two digital radiation tolerant integrated circuits for high energy physics experiments data readout

    CERN Document Server

    Bonacini, Sandro

    2003-01-01

    High Energy Physics research (HEP) involves the design of readout electron- ics for its experiments, which generate a high radiation ¯eld in the detectors. The several integrated circuits placed in the future Large Hadron Collider (LHC) experiments' environment have to resist the radiation and carry out their normal operation. In this thesis I will describe in detail what, during my 10-months partic- ipation in the digital section of the Microelectronics group at CERN, I had the possibility to work on: - The design of a radiation-tolerant data readout digital integrated cir- cuit in a 0.25 ¹m CMOS technology, called \\the Kchip", for the CMS preshower front-end system. This will be described in Chapter 3. - The design of a radiation-tolerant SRAM integrated circuit in a 0.13 ¹m CMOS technology, for technology radiation testing purposes and fu- ture applications in the HEP ¯eld. The SRAM will be described in Chapter 4. All the work has carried out under the supervision and with the help of Dr. Kostas Klouki...

  3. CMS computing on grid

    International Nuclear Information System (INIS)

    Guan Wen; Sun Gongxing

    2007-01-01

    CMS has adopted a distributed system of services which implement CMS application view on top of Grid services. An overview of CMS services will be covered. Emphasis is on CMS data management and workload Management. (authors)

  4. Timing and Readout Contorl in the LHCb Upgraded Readout System

    CERN Document Server

    Alessio, Federico

    2016-01-01

    In 2019, the LHCb experiment at CERN will undergo a major upgrade where its detectors electronics and entire readout system will be changed to read-out events at the full LHC rate of 40 MHz. In this paper, the new timing, trigger and readout control system for such upgrade is reviewed. Particular attention is given to the distribution of the clock, timing and synchronization information across the entire readout system using generic FTTH technology like Passive Optical Networks. Moreover the system will be responsible to generically control the Front-End electronics by transmitting configuration data and receiving monitoring data, offloading the software control system from the heavy task of manipulating complex protocols of thousands of Front-End electronics devices. The way in which this was implemented is here reviewed with a description of results from first implementations of the system, including usages in test-benches, implementation of techniques for timing distribution and latency control."

  5. Pixel detector readout chip

    CERN Multimedia

    1991-01-01

    Close-up of a pixel detector readout chip. The photograph shows an aera of 1 mm x 2 mm containing 12 separate readout channels. The entire chip contains 1000 readout channels (around 80 000 transistors) covering a sensitive area of 8 mm x 5 mm. The chip has been mounted on a silicon detector to detect high energy particles.

  6. [Evaluation of Image Quality of Readout Segmented EPI with Readout Partial Fourier Technique].

    Science.gov (United States)

    Yoshimura, Yuuki; Suzuki, Daisuke; Miyahara, Kanae

    Readout segmented EPI (readout segmentation of long variable echo-trains: RESOLVE) segmented k-space in the readout direction. By using the partial Fourier method in the readout direction, the imaging time was shortened. However, the influence on image quality due to insufficient data sampling is concerned. The setting of the partial Fourier method in the readout direction in each segment was changed. Then, we examined signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and distortion ratio for changes in image quality due to differences in data sampling. As the number of sampling segments decreased, SNR and CNR showed a low value. In addition, the distortion ratio did not change. The image quality of minimum sampling segments is greatly different from full data sampling, and caution is required when using it.

  7. Production of the new pixel detector for the upgrade of the CMS experiment and study of anomalous couplings in the non-resonant Higgs bosons pair production in p-p collisions at $\\sqrt{s}$ = 13 TeV

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00367286; Dorigo, Tommaso

    2016-01-01

    The present Ph.D thesis describes the work done within the CMS collaboration on the pixel detector upgrade and on the search for non-resonant di-Higgs production in p-p collision at LHC. The CMS upgrade project foresees, inter alia, the production of a new pixel detector (CMS Phase 1 Pixel Upgrade) to be commissioned at the beginning of 2017. Crucial part of the upgrade is the new readout chip (ROC) for the silicon sensor, psi46digV2respin, designed at the Paul Scherrer Institute (PSI) with a 250 nm CMOS technology. The thesis concerns the study and the development of test procedures for this new readout chip. Thanks to a long stay at PSI, I could provide an important contribution to the debug phases of the first version of the ROC and TBM, the chip that handles the various ROCs in the pixel module, and to the development of the software used by the whole collaboration for the ROC and module testing. Furthermore, I managed the ROC wafers test from the early project phases. The ROCs are produced on silicon wa...

  8. The "KATOD-1" Strip Readout ASIC for Cathode Strip Chamber

    CERN Document Server

    Golutvin, I A; Karjavin, V Yu; Khabarov, V S; Movchan, S A; Smolin, D A; Dvornikov, O V; Shumeiko, N M; Tchekhovski, V A

    2001-01-01

    The "KATOD-1", a 16-channels readout ASIC, has been designed to perform tests of P3 and P4 full-scale prototypes of the cathode strip chamber for the ME1/1 forward muon station of the Compact Muon Solenoid (CMS) experiment. The ASIC channel consists of two charge-sensitive preamplifiers, a three-stage shaper with tail cancellation, and an output driver. The ASIC is instrumented with control of gain, in the range of (-4.2\\div +5.0) mV/fC, and control of output pulse-shape. The equivalent input noise is equal to 2400 e with the slope of 12 e/pF for detector capacity up to 200 pF. The peaking time is 100 ns for the chamber signal. The ASIC has been produced by a microwave Bi-jFET technology.

  9. CMS Statistics

    Data.gov (United States)

    U.S. Department of Health & Human Services — The CMS Center for Strategic Planning produces an annual CMS Statistics reference booklet that provides a quick reference for summary information about health...

  10. Qualification of barrel pixel detector modules for the Phase 1 Upgrade of the CMS vertex detector

    CERN Document Server

    Kudella, Simon

    2016-01-01

    To withstand the higher particle rates of LHC Runs 2 and 3, with expected luminosities of up to $2\\times 10^{34}\\,\\mathrm{cm^{-2}s^{-1}}$, the current CMS pixel detector at the LHC will be replaced as part of the CMS Phase I Upgrade during the extended winter shutdown in 2016/17. The new pixel detector features a new geometry with one additional detector layer in the barrel region~(BPIX) and one pair of additional disks in the forward region~(FPIX), new digital readout chips as well as a new CO$_{2}$-based cooling system for both the barrel and forward region. The BPIX detector module production is summarized, with special focus on the different stages of quality assurance. The quality tests as well as the calibrations which all produced modules undergo in a temperature and humidity controlled environment are described. Exemplarily, the KIT/Aachen production line and its subprocesses are presented together with its quality and yields.

  11. CMS offline web tools

    International Nuclear Information System (INIS)

    Metson, S; Newbold, D; Belforte, S; Kavka, C; Bockelman, B; Dziedziniewicz, K; Egeland, R; Elmer, P; Eulisse, G; Tuura, L; Evans, D; Fanfani, A; Feichtinger, D; Kuznetsov, V; Lingen, F van; Wakefield, S

    2008-01-01

    We describe a relatively new effort within CMS to converge on a set of web based tools, using state of the art industry techniques, to engage with the CMS offline computing system. CMS collaborators require tools to monitor various components of the computing system and interact with the system itself. The current state of the various CMS web tools is described along side current planned developments. The CMS collaboration comprises of nearly 3000 people from all over the world. As well as its collaborators, its computing resources are spread all over globe and are accessed via the LHC grid to run analysis, large scale production and data transfer tasks. Due to the distributed nature of collaborators effective provision of collaborative tools is essential to maximise physics exploitation of the CMS experiment, especially when the size of the CMS data set is considered. CMS has chosen to provide such tools over the world wide web as a top level service, enabling all members of the collaboration to interact with the various offline computing components. Traditionally web interfaces have been added in HEP experiments as an afterthought. In the CMS offline we have decided to put web interfaces, and the development of a common CMS web framework, on an equal footing with the rest of the offline development. Tools exist within CMS to transfer and catalogue data (PhEDEx and DBS/DLS), run Monte Carlo production (ProdAgent) and submit analysis (CRAB). Effective human interfaces to these systems are required for users with different agendas and practical knowledge of the systems to effectively use the CMS computing system. The CMS web tools project aims to provide a consistent interface to all these tools

  12. CMS offline web tools

    Energy Technology Data Exchange (ETDEWEB)

    Metson, S; Newbold, D [H.H. Wills Physics Laboratory, University of Bristol, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Belforte, S; Kavka, C [INFN, Sezione di Trieste (Italy); Bockelman, B [University of Nebraska Lincoln, Lincoln, NE (United States); Dziedziniewicz, K [CERN, Geneva (Switzerland); Egeland, R [University of Minnesota Twin Cities, Minneapolis, MN (United States); Elmer, P [Princeton (United States); Eulisse, G; Tuura, L [Northeastern University, Boston, MA (United States); Evans, D [Fermilab MS234, Batavia, IL (United States); Fanfani, A [Universita degli Studi di Bologna (Italy); Feichtinger, D [PSI, Villigen (Switzerland); Kuznetsov, V [Cornell University, Ithaca, NY (United States); Lingen, F van [California Institute of Technology, Pasedena, CA (United States); Wakefield, S [Blackett Laboratory, Imperial College, London (United Kingdom)

    2008-07-15

    We describe a relatively new effort within CMS to converge on a set of web based tools, using state of the art industry techniques, to engage with the CMS offline computing system. CMS collaborators require tools to monitor various components of the computing system and interact with the system itself. The current state of the various CMS web tools is described along side current planned developments. The CMS collaboration comprises of nearly 3000 people from all over the world. As well as its collaborators, its computing resources are spread all over globe and are accessed via the LHC grid to run analysis, large scale production and data transfer tasks. Due to the distributed nature of collaborators effective provision of collaborative tools is essential to maximise physics exploitation of the CMS experiment, especially when the size of the CMS data set is considered. CMS has chosen to provide such tools over the world wide web as a top level service, enabling all members of the collaboration to interact with the various offline computing components. Traditionally web interfaces have been added in HEP experiments as an afterthought. In the CMS offline we have decided to put web interfaces, and the development of a common CMS web framework, on an equal footing with the rest of the offline development. Tools exist within CMS to transfer and catalogue data (PhEDEx and DBS/DLS), run Monte Carlo production (ProdAgent) and submit analysis (CRAB). Effective human interfaces to these systems are required for users with different agendas and practical knowledge of the systems to effectively use the CMS computing system. The CMS web tools project aims to provide a consistent interface to all these tools.

  13. CMS MANANGEMENT MEETINGS

    CERN Multimedia

    Management Board Agendas and minutes of meetings of the Management Board are accessible to CMS members at: http://indico.cern.ch/categoryDisplay.py?categId=223 Collaboration Board Agendas and minutes of meetings of the Collaboration Board are accessible to CMS members at: http://indico.cern.ch/categoryDisplay.py?categId=174 LHCC: Feedback from the CMS Referees, LHCC 97 February 25, 2009. The CMS LHCC referees met with representatives of CMS on 17-2-09, to review progress since the last November minireview. The main topics included shutdown construction, maintenance and repairs; status of the preshower detector; commissioning and physics analysis results from cosmic ray running and CSA08; preparations for physics, off line analysis, computing, and data distribution. TOTEM management and the TOTEM referees then joined us for a joint session to examine the readiness of the TOTEM detector. Detector construction, maintenance, and repairs. The referees congratulate CMS Management and the Detector Groups for the...

  14. Commissioning of the CMS Hadron Forward Calorimeters Phase I Upgrade

    CERN Document Server

    Bilki, Burak

    2017-01-01

    The final phase of the CMS Hadron Forward Calorimeters Phase I upgrade is being performed during the Extended Year End Technical Stop of 2016 â?? 2017. In the framework of the upgrade, the PMT boxes are being reworked to implement two channel readout in order to exploit the benefits of the multi-anode PMTs in background tagging and signal recovery. The front-end electronics is also being upgraded to QIE10-based electronics which will implement larger dynamic range and a 6-bit TDC to eliminate the background to have an effect on the trigger. Following this major upgrade, the Hadron Forward Calorimeters will be commissioned for operation readiness in 2017. Here we describe the details and the components of the upgrade, and discuss the operational experience and results obtained during the upgrade and commissioning.

  15. Planar sensors for the upgrade of the CMS pixel detector

    International Nuclear Information System (INIS)

    Rohe, T.; Bean, A.; Radicci, V.; Sibille, J.

    2011-01-01

    A replacement of the present CMS pixel detector with a better performing light weight four-layer system is foreseen in 2016. In the lifetime of this new system the LHC will reach and exceed its nominal luminosity of 10 34 cm -2 s -1 . Therefore the radiation hardness of all parts of the pixel system has to be reviewed. For the construction of the much larger four-layer pixel system, the replacement of the present double sided sensors by much cheaper single sided ones is considered. However, the construction of pixel modules with such sensors is challenging due to the small geometrical distance of the sensor high voltage and the ground of the readout electronics. This small distance limits the sensor bias to about 500 V in the tested samples.

  16. Flexible custom designs for CMS DAQ

    CERN Document Server

    Arcidiacono, Roberta; Boyer, Vincent; Brett, Angela Mary; Cano, Eric; Carboni, Andrea; Ciganek, Marek; Cittolin, Sergio; Erhan, Samim; Gigi, Dominique; Glege, Frank; Gomez-Reino Garrido, Robert; Gulmini, Michele; Gutleber, Johannes; Jacobs, Claude; Maron, Gaetano; Meijers, Frans; Meschi, Emilio; Murray, Steven John; Oh, Alexander; Orsini, Luciano; Paus, Christoph; Petrucci, Andrea; Piedra Gomez, Jonatan; Pieri, Marco; Pollet, Lucien; Racz, Attila; Sakulin, Hannes; Schwick, Christoph; Sumorok, Konstanty; Suzuki, Ichiro; Tsirigkas, Dimitrios; Varela, Joao

    2006-01-01

    The CMS central DAQ system is built using commercial hardware (PCs and networking equipment), except for two components: the Front-end Readout Link (FRL) and the Fast Merger Module (FMM). The FRL interfaces the sub-detector specific front-end electronics to the central DAQ system in a uniform way. The FRL is a compact-PCI module with an additional PCI 64bit connector to host a Network Interface Card (NIC). On the sub-detector side, the data are written to the link using a FIFO-like protocol (SLINK64). The link uses the Low Voltage Differential Signal (LVDS) technology to transfer data with a throughput of up to 400 MBytes/s. The FMM modules collect status signals from the front-end electronics of the sub-detectors, merge and monitor them and provide the resulting signals with low latency to the first level trigger electronics. In particular, the throttling signals allow the trigger to avoid buffer overflows and data corruption in the front-end electronics when the data produced in the front-end exceeds the c...

  17. Testing and Integration of the Service Cylinders for the CMS Phase 1 pixel detector

    CERN Document Server

    Ngadiuba, Jennifer

    2016-01-01

    The present 3-layer CMS pixel detector will be replaced with a new 4-layer pixel system, referred to as Phase~1 upgrade, during the LHC extended technical stop in winter 2016/2017. The upgraded detector will allow to maintain the excellent tracking performance of CMS at the upcoming higher luminosity conditions at the LHC. The addition of an extra layer, closer to the beam pipe, demands a complete redesign of its services. The barrel pixel detector is attached to four half cylinders which carry the services along the beam pipe, accommodate the cooling lines and house the electronics for detector readout and control. The service cylinders are a complex system in design as well as in production due to the large number of channels and tight space requirements. In this document we present the design of the system and discuss the construction and testing of the service cylinders for the barrel pixel detector. Furthermore, we present results of the testing and calibrations carried out with a set of new digital dete...

  18. Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector

    CERN Document Server

    Dragicevic, M.; Hrubec, J.; Steininger, H.; Gädda, A.; Härkönen, J.; Lampén, T.; Luukka, P.; Peltola, T.; Tuominen, E.; Tuovinen, E.; Winkler, A.; Eerola, P.; Tuuva, T.; Baulieu, G.; Boudoul, G.; Caponetto, L.; Combaret, C.; Contardo, D.; Dupasquier, T.; Gallbit, G.; Lumb, N.; Mirabito, L.; Perries, S.; Donckt, M.Vander; Viret, S.; Bonnin, C.; Charles, L.; Gross, L.; Hosselet, J.; Tromson, D.; Feld, L.; Karpinski, W.; Klein, K.; Lipinski, M.; Pierschel, G.; Preuten, M.; Rauch, M.; Wlochal, M.; Aldaya, M.; Asawatangtrakuldee, C.; Beernaert, K.; Bertsche, D.; Contreras-Campana, C.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Gallo, E.; Garcia, J.Garay; Hansen, K.; Haranko, M.; Harb, A.; Hauk, J.; Keaveney, J.; Kalogeropoulos, A.; Kleinwort, C.; Lohmann, W.; Mankel, R.; Maser, H.; Mittag, G.; Muhl, C.; Mussgiller, A.; Pitzl, D.; Reichelt, O.; Savitskyi, M.; Schütze, P.; Sola, V.; Spannagel, S.; Walsh, R.; Zuber, A.; Biskop, H.; Buhmann, P.; Centis-Vignali, M.; Garutti, E.; Haller, J.; Hoffmann, M.; Klanner, R.; Lapsien, T.; Matysek, M.; Perieanu, A.; Scharf, Ch.; Schleper, P.; Schmidt, A.; Schwandt, J.; Sonneveld, J.; Steinbrück, G.; Vormwald, B.; Wellhausen, J.; Abbas, M.; Amstutz, C.; Barvich, T.; Barth, Ch.; Boegelspacher, F.; Boer, W.De; Butz, E.; Casele, M.; Colombo, F.; Dierlamm, A.; Freund, B.; Hartmann, F.; Heindl, S.; Husemann, U.; Kornmeyer, A.; Kudella, S.; Muller, Th.; Simonis, H.J.; Steck, P.; Weber, M.; Weiler, Th.; Kiss, T.; Siklér, F.; Tölyhi, T.; Veszprémi, V.; Cariola, P.; Creanza, D.; Palma, M.De; Robertis, G.De; Fiore, L.; Franco, M.; Loddo, F.; Sala, G.; Silvestris, L.; Maggi, G.; My, S.; Selvaggi, G.; Albergo, S.; Cappello, G.; Costa, S.; Mattia, A.Di; Giordano, F.; Potenza, R.; Saizu, M.A.; Tricomi, A.; Tuve, C.; Focardi, E.; Dinardo, M.E.; Fiorendi, S.; Gennai, S.; Malvezzi, S.; Manzoni, R.A.; Menasce, D.; Moroni, L.; Pedrini, D.; Azzi, P.; Bacchetta, N.; Bisello, D.; Dall'Osso, M.; Pozzobon, N.; Tosi, M.; Solestizi, L.Alunni; Biasini, M.; Bilei, G.M.; Cecchi, C.; Checcucci, B.; Ciangottini, D.; Fanò, L.; Gentsos, C.; Ionica, M.; Leonardi, R.; Manoni, E.; Mantovani, G.; Marconi, S.; Mariani, V.; Menichelli, M.; Modak, A.; Morozzi, A.; Moscatelli, F.; Passeri, D.; Placidi, P.; Postolache, V.; Rossi, A.; Saha, A.; Santocchia, A.; Storchi, L.; Spiga, D.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Basti, A.; Boccali, T.; Borrello, L.; Bosi, F.; Castaldi, R.; Ceccanti, M.; Ciocci, M.A.; Dell'Orso, R.; Donato, S.; Fedi, G.; Giassi, A.; Grippo, M.T.; Ligabue, F.; Magazzu, G.; Mammini, P.; Mariani, F.; Mazzoni, E.; Messineo, A.; Moggi, A.; Morsani, F.; Palla, F.; Palmonari, F.; Profeti, A.; Raffaelli, F.; Ragonesi, A.; Rizzi, A.; Soldani, A.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P.G.; Abbaneo, D.; Ahmed, I.; Albert, E.; Auzinger, G.; Berruti, G.; Bonnaud, J.; Daguin, J.; D'Auria, A.; Detraz, S.; Dondelewski, O.; Engegaard, B.; Faccio, F.; Frank, N.; Gill, K.; Honma, A.; Kornmayer, A.; Labaza, A.; Manolescu, F.; McGill, I.; Mersi, S.; Michelis, S.; Onnela, A.; Ostrega, M.; Pavis, S.; Peisert, A.; Pernot, J.F.; Petagna, P.; Postema, H.; Rapacz, K.; Sigaud, C.; Tropea, P.; Troska, J.; Tsirou, A.; Vasey, F.; Verlaat, B.; Vichoudis, P.; Zwalinski, L.; Bachmair, F.; Becker, R.; di Calafiori, D.; Casal, B.; Berger, P.; Djambazov, L.; Donega, M.; Grab, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Lustermann, W.; Mangano, B.; Marionneau, M.; Arbol, P.Martinez Ruiz del; Masciovecchio, M.; Meinhard, M.; Perozzi, L.; Roeser, U.; Starodumov, A.; Tavolaro, V.; Wallny, R.; Zhu, D.; Amsler, C.; Bösiger, K.; Caminada, L.; Canelli, F.; Chiochia, V.; de Cosa, A.; Galloni, C.; Hreus, T.; Kilminster, B.; Lange, C.; Maier, R.; Ngadiuba, J.; Pinna, D.; Robmann, P.; Taroni, S.; Yang, Y.; Bertl, W.; Deiters, K.; Erdmann, W.; Horisberger, R.; Kaestli, H.C.; Kotlinski, D.; Langenegger, U.; Meier, B.; Rohe, T.; Streuli, S.; Chen, P.H.; Dietz, C.; Fiori, F.; Grundler, U.; Hou, W.S.; Lu, R.S.; Moya, M.; Tsai, J.F.; Tzeng, Y.M.; Cussans, D.; Goldstein, J.; Grimes, M.; Newbold, D.; Hobson, P.; Reid, I.D.; Auzinger, G.; Bainbridge, R.; Dauncey, P.; Hall, G.; James, T.; Magnan, A.M.; Pesaresi, M.; Raymond, D.M.; Uchida, K.; Durkin, T.; Harder, K.; Shepherd-Themistocleous, C.; Chertok, M.; Conway, J.; Conway, R.; Flores, C.; Lander, R.; Pellett, D.; Ricci-Tam, F.; Squires, M.; Thomson, J.; Yohay, R.; Burt, K.; Ellison, J.; Hanson, G.; Olmedo, M.; Si, W.; Yates, B.R.; Dominguez, A.; Bartek, R.; Bentele, B.; Cumalat, J.P.; Ford, W.T.; Jensen, F.; Johnson, A.; Krohn, M.; Leontsinis, S.; Mulholland, T.; Stenson, K.; Wagner, S.R.; Apresyan, A.; Bolla, G.; Burkett, K.; Butler, J.N.; Canepa, A.; Cheung, H.W.K.; Christian, D.; Cooper, W.E.; Deptuch, G.; Derylo, G.; Gingu, C.; Grünendahl, S.; Hasegawa, S.; Hoff, J.; Howell, J.; Hrycyk, M.; Jindariani, S.; Johnson, M.; Kahlid, F.; Kwan, S.; Lei, C.M.; Lipton, R.; Sá, R.Lopes De; Liu, T.; Los, S.; Matulik, M.; Merkel, P.; Nahn, S.; Prosser, A.; Rivera, R.; Schneider, B.; Sellberg, G.; Shenai, A.; Siehl, K.; Spiegel, L.; Tran, N.; Uplegger, L.; Voirin, E.; Berry, D.R.; Chen, X.; Ennesser, L.; Evdokimov, A.; Gerber, C.E.; Makauda, S.; Mills, C.; Gonzalez, I.D.Sandoval; Alimena, J.; Antonelli, L.J.; Francis, B.; Hart, A.; Hill, C.S.; Parashar, N.; Stupak, J.; Bortoletto, D.; Bubna, M.; Hinton, N.; Jones, M.; Miller, D.H.; Shi, X.; Baringer, P.; Bean, A.; Khalil, S.; Kropivnitskaya, A.; Majumder, D.; Schmitz, E.; Wilson, G.; Ivanov, A.; Mendis, R.; Mitchell, T.; Skhirtladze, N.; Taylor, R.; Anderson, I.; Fehling, D.; Gritsan, A.; Maksimovic, P.; Martin, C.; Nash, K.; Osherson, M.; Swartz, M.; Xiao, M.; Acosta, J.G.; Cremaldi, L.M.; Oliveros, S.; Perera, L.; Summers, D.; Bloom, K.; Claes, D.R.; Fangmeier, C.; Suarez, R.Gonzalez; Monroy, J.; Siado, J.; Bartz, E.; Gershtein, Y.; Halkiadakis, E.; Kyriacou, S.; Lath, A.; Nash, K.; Osherson, M.; Schnetzer, S.; Stone, R.; Walker, M.; Malik, S.; Norberg, S.; Vargas, J.E.Ramirez; Alyari, M.; Dolen, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Kharchilava, A.; Nguyen, D.; Parker, A.; Rappoccio, S.; Roozbahani, B.; Alexander, J.; Chaves, J.; Chu, J.; Dittmer, S.; McDermott, K.; Mirman, N.; Rinkevicius, A.; Ryd, A.; Salvati, E.; Skinnari, L.; Soffi, L.; Tao, Z.; Thom, J.; Tucker, J.; Zientek, M.; Akgün, B.; Ecklund, K.M.; Kilpatrick, M.; Nussbaum, T.; Zabel, J.; D'Angelo, P.; Johns, W.; Rose, K.

    2017-05-30

    A new pixel detector for the CMS experiment is being built, owing to the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking while featuring a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and comprises a low-threshold comparator. These upgrades allow the new pixel detector to sustain and improve the efficiency of the current pixel tracker at the increased requirements imposed by high luminosities and pile-up. In this paper, comprehensive test beam studies are presented which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency has been determined to be ($99.95 \\pm 0.05$) \\%, while the intrinsic spatial resolution has been measured to be ($4.80 \\pm 0.25$) $\\mu$m and ($7.99 \\pm 0.21$...

  19. Prototypdetektoren für das geplante Upgradeprojekt 'Muon Track Fast Tag' am CMS-Experiment

    CERN Document Server

    Weingarten, Simon; Stahl, Achim

    Upgrading the muon system will be one of the major challenges for the CMS experiment atthe projected high luminosity LHC (HL-LHC) with an expected instantaneous luminosityof L = 1035 /(cm2 · s). Most importantly, the muon trigger rate has to be reduced inorder to keep the level 1 trigger rate inside the reserved bandwidth. Another concernthat has to be dealt with is the rising number of ambiguities in the muon chambers dueto simultaneously traversing muons, so-called ghost hits. With the Muon Track fast Tag(MTT), a new detector subsystem between the CMS solenoid and the first muon stationis proposed to solve these problems. An implementation of the MTT system based on fastplastic scintillators read out by silicon photomultipliers (SiPM) is under development atthe Physics Institute III of RWTH Aachen University.In this thesis, results of prototype detectors with 100 × 100 × 5 mm3 scintillator-tilesand dual SiPM-readout are presented. All studies have been done with cosmic muons andfocus on parameter optimi...

  20. Development and Evaluation of Test Stations for the Quality Assurance of the Silicon Micro-Strip Detector Modules for the CMS Experiment

    CERN Document Server

    Pöttgens, Michael

    2007-01-01

    CMS (Compact Muon Solenoid) is one of four large-scale detectors which will be operated at the LHC (Large Hadron Collider) at the European Laboratory for Particle Physics (CERN). For the search for new physics the reconstruction of the collision products and their properties is essential. In the innermost part of the CMS detector the traces of ionizing particles are measured utilizing a silicon tracker. A large fraction of this detector is equipped with silicon micro-strip modules which provide a precise space resolution in 1-dimension. A module consists of a sensor for detection of particles, the corresponding read-out electronics (hybrid) and a mechanical support structure. Since the 15,148 modules, which will be installed in the silicon micro-strip detector, have a total sensitive surface area of about 198 m2, the inner tracker of CMS is the largest silicon tracking detector, which has ever been built. While the sensors and hybrids are produced in industry, the construction of the modules and the control o...

  1. CMS Centre at CERN

    CERN Multimedia

    2007-01-01

    A new "CMS Centre" is being established on the CERN Meyrin site by the CMS collaboration. It will be a focal point for communications, where physicists will work together on data quality monitoring, detector calibration, offline analysis of physics events, and CMS computing operations. Construction of the CMS Centre begins in the historic Proton Synchrotron (PS) control room. The historic Proton Synchrotron (PS) control room, Opened by Niels Bohr in 1960, will be reused by CMS to built its control centre. TThe LHC@FNAL Centre, in operation at Fermilab in the US, will work very closely with the CMS Centre, as well as the CERN Control Centre. (Photo Fermilab)The historic Proton Synchrotron (PS) control room is about to start a new life. Opened by Niels Bohr in 1960, the room will be reused by CMS to built its control centre. When finished, it will resemble the CERN Contro...

  2. Optical readout and control interface for the BTeV pixel vertex detector

    CERN Document Server

    Vergara-Limon, S; Sheaff, M; Vargas, M A

    2002-01-01

    Optical links will be used for sending data back and forth from the counting room to the detector in the data acquisition systems for future high energy physics experiments, including ATLAS and CMS in the LHC at CERN (Switzerland) and BTeV at Fermilab (USA). This is because they can be ultra-high speed and are relatively immune to electro-magnetic interference (EMI). The baseline design for the BTeV Pixel Vertex Detector includes two types of optical link, one to control and monitor and the other to read out the hit data from the multi-chip modules on each half-plane of the detector. The design and performance of the first prototype of the Optical Readout and Control Interface for the BTeV Pixel Vertex Detector is described.

  3. Operational experience with the CMS Data Acquisition System

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    The data-acquisition (DAQ) system of the CMS experiment at the LHC performs the read-out and assembly of events accepted by the first level hardware trigger. Assembled events are made available to the high-level trigger (HLT), which selects interesting events for offline storage and analysis. The system is designed to handle a maximum input rate of 100 kHz and an aggregated throughput of 100 GB/s originating from approximately 500 sources and 10^8 electronic channels. An overview of the architecture and design of the hardware and software of the DAQ system is given. We report on the performance and operational experience of the DAQ and its Run Control System in the first two years of collider run of the LHC, both in proton-proton and Pb-Pb collisions. We present an analysis of the current performance, its limitations, and the most common failure modes and discuss the ongoing evolution of the HLT capability needed to match the luminosity ramp-up of the LHC.

  4. CERN Open Days 2013, Point 5 - CMS: CMS Experiment

    CERN Multimedia

    CERN Photolab

    2013-01-01

    Stand description: Come to LHC's Point 5 and visit the Compact Muon Solenoid (CMS) experiment that discovered the Higgs boson ! Descend 100 metres underground and take a walk in the cathedral-sized cavern housing the 14,000-tonne CMS detector. Ask Higgs hunters and other scientists just about anything, be it questions about their work, particle physics or the engineering challenges of building CMS.  On surface no restricted access  Point 5 will be abuzz all day long with activities for all ages, including literally "cool" cryogenics shows featuring the world's fastest ice-cream maker, dance performances, and much more.

  5. CMS MANAGEMENT MEETINGS

    CERN Multimedia

    Management Board Agendas and minutes of meetings of the Management Board are accessible to CMS members at: http://indico.cern.ch/categoryDisplay.py?categId=223 Collaboration Board Agendas and minutes of meetings of the Collaboration Board are accessible to CMS members at: http://indico.cern.ch/categoryDisplay.py?categId=174 LHCC: Feedback from the CMS Referees, LHCC 97 February 25, 2009. The CMS LHCC referees met with representatives of CMS on 17-2-09, to review progress since the last November minireview. The main topics included  shutdown construction, maintenance and repairs;  status of the preshower detector; commissioning and physics analysis results from cosmic ray running and CSA08;   preparations for physics, off line analysis, computing, and data distribution. TOTEM management and the TOTEM referees then joined us for a joint session to examine the readiness of the TOTEM detector. Detector construction, maintenance, and repairs. The referees congratulate C...

  6. CMS Thesis Award

    CERN Multimedia

    2004-01-01

    The 2003 CMS thesis award was presented to Riccardo Ranieri on 15 March for his Ph.D. thesis "Trigger Selection of WH → μ ν b bbar with CMS" where 'WH → μ ν b bbar' represents the associated production of the W boson and the Higgs boson and their subsequent decays. Riccardo received his Ph.D. from the University of Florence and was supervised by Carlo Civinini. In total nine thesis were nominated for the award, which was judged on originality, impact within the field of high energy physics, impact within CMS and clarity of writing. Gregory Snow, secretary of the awarding committee, explains why Riccardo's thesis was chosen, ‘‘The search for the Higgs boson is one of the main physics goals of CMS. Riccardo's thesis helps the experiment to formulate the strategy which will be used in that search.'' Lorenzo Foà, Chairperson of the CMS Collaboration Board, presented Riccardo with an commemorative engraved plaque. He will also receive the opportunity to...

  7. CMS MANAGEMENT MEETINGS

    CERN Multimedia

    Jim Virdee

    Management Board Agendas and minutes of meetings of the Management Board are accessible to CMS members at: http://indico.cern.ch/categoryDisplay.py?categId=223 Collaboration Board Agendas and minutes of meetings of the Collaboration Board are accessible to CMS members at: http://indico.cern.ch/categoryDisplay.py?categId=174 LHCC: Feedback from the CMS Referees, LHCC 97 February 25, 2009. The CMS LHCC referees met with representatives of CMS on 17-2-09, to review progress since the last November minireview. The main topics included  shutdown construction, maintenance and repairs;  status of the preshower detector; commissioning and physics analysis results from cosmic ray running and CSA08;   preparations for physics, off line analysis, computing, and data distribution. TOTEM management and the TOTEM referees then joined us for a joint session to examine the readiness of the TOTEM detector. Detector construction, maintenance, and repairs. The referees congratula...

  8. Dose-ranging pharmacokinetics of colistin methanesulphonate (CMS) and colistin in rats following single intravenous CMS doses.

    Science.gov (United States)

    Marchand, Sandrine; Lamarche, Isabelle; Gobin, Patrice; Couet, William

    2010-08-01

    The aim of this study was to evaluate the effect of colistin methanesulphonate (CMS) dose on CMS and colistin pharmacokinetics in rats. Three rats per group received an intravenous bolus of CMS at a dose of 5, 15, 30, 60 or 120 mg/kg. Arterial blood samples were drawn at 0, 5, 15, 30, 60, 90, 120, 150 and 180 min. CMS and colistin plasma concentrations were determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The pharmacokinetic parameters of CMS and colistin were calculated by non-compartmental analysis. Linear relationships were observed between CMS and colistin AUCs to infinity and CMS doses, as well as between CMS and colistin C(max) and CMS doses. CMS and colistin pharmacokinetics were linear for a range of colistin concentrations covering the range of values encountered and recommended in patients even during treatment with higher doses.

  9. Readout electronic for multichannel detectors

    CERN Document Server

    Kulibaba, V I; Naumov, S V

    2001-01-01

    Readout electronics based on the 128-channel chip 'Viking' (IDE AS inc., Norway) is considered. The chip 'Viking' integrates 128 low noise charge-sensitive preamplifiers with tunable CR-(RC) sup 2 shapers,analog memory and multiplexed readout to one output. All modules of readout electronics were designed and produced in KIPT taking into account the published recommendations of IDE AS inc.

  10. Readout electronic for multichannel detectors

    International Nuclear Information System (INIS)

    Kulibaba, V.I.; Maslov, N.I.; Naumov, S.V.

    2001-01-01

    Readout electronics based on the 128-channel chip 'Viking' (IDE AS inc., Norway) is considered. The chip 'Viking' integrates 128 low noise charge-sensitive preamplifiers with tunable CR-(RC) 2 shapers,analog memory and multiplexed readout to one output. All modules of readout electronics were designed and produced in KIPT taking into account the published recommendations of IDE AS inc

  11. Sensor development for the CMS pixel detector

    CERN Document Server

    Bölla, G; Horisberger, R P; Kaufmann, R; Rohe, T; Roy, A

    2002-01-01

    The CMS experiment which is currently under construction at the Large Hadron Collider (LHC) at CERN (Geneva, Switzerland) will contain a pixel detector which provides in its final configuration three space points per track close to the interaction point of the colliding beams. Because of the harsh radiation environment of the LHC, the technical realization of the pixel detector is extremely challenging. The readout chip as the most damageable part of the system is believed to survive a particle fluence of 6x10 sup 1 sup 4 n sub e sub q /cm sup 2 (All fluences are normalized to 1 MeV neutrons and therefore all components of the hybrid pixel detector have to perform well up to at least this fluence. As this requires a partially depleted operation of the silicon sensors after irradiation-induced type inversion of the substrate, an ''n in n'' concept has been chosen. In order to perform IV-tests on wafer level and to hold accidentally unconnected pixels close to ground potential, a resistive path between the pixe...

  12. Pre- and post-irradiation performance of FBK 3D silicon pixel detectors for CMS

    International Nuclear Information System (INIS)

    Krzywda, A.; Alagoz, E.; Bubna, M.; Obertino, M.; Solano, A.; Arndt, K.; Uplegger, L.; Betta, G.F. Dalla; Boscardin, M.; Ngadiuba, J.; Rivera, R.; Menasce, D.; Moroni, L.; Terzo, S.; Bortoletto, D.; Prosser, A.; Adreson, J.; Kwan, S.; Osipenkov, I.; Bolla, G.

    2014-01-01

    In preparation for the tenfold luminosity upgrade of the Large Hadron Collider (the HL-LHC) around 2020, three-dimensional (3D) silicon pixel sensors are being developed as a radiation-hard candidate to replace the planar ones currently being used in the CMS pixel detector. This study examines an early batch of FBK sensors (named ATLAS08) of three 3D pixel geometries: 1E, 2E, and 4E, which respectively contain one, two, and four readout electrodes for each pixel, passing completely through the bulk. We present electrical characteristics and beam test performance results for each detector before and after irradiation. The maximum fluence applied is 3.5×10 15 n eq /cm 2

  13. The Detector Control Unit An ASIC for the monitoring of the CMS silicon tracker

    CERN Document Server

    Magazzù, G; Moreira, P

    2004-01-01

    The Detector Control Unit (DCU) is an ASIC developed as the central building block of a monitoring system for the CMS Tracker. Leakage currents in the Silicon detectors, power supply voltages of the readout electronics and local temperatures will be monitored in order to guarantee safe operating conditions during the 10-years lifetime in the LHC environment. All these measurements can be performed by an A/D converter preceded by an analog multiplexer and properly interfaced to the central control system. The requirements in terms of radiation tolerance, low-power dissipation and integration with the rest of the system led to the design of a custom integrated circuit. Its structure and characteristics are described in this paper. (6 refs).

  14. CMS Central Hadron Calorimeter

    OpenAIRE

    Budd, Howard S.

    2001-01-01

    We present a description of the CMS central hadron calorimeter. We describe the production of the 1996 CMS hadron testbeam module. We show the results of the quality control tests of the testbeam module. We present some results of the 1995 CMS hadron testbeam.

  15. CMS Records Schedule

    Data.gov (United States)

    U.S. Department of Health & Human Services — The CMS Records Schedule provides disposition authorizations approved by the National Archives and Records Administration (NARA) for CMS program-related records...

  16. CMS analysis school model

    International Nuclear Information System (INIS)

    Malik, S; Bloom, K; Shipsey, I; Cavanaugh, R; Klima, B; Chan, Kai-Feng; D'Hondt, J; Narain, M; Palla, F; Rolandi, G; Schörner-Sadenius, T

    2014-01-01

    To impart hands-on training in physics analysis, CMS experiment initiated the concept of CMS Data Analysis School (CMSDAS). It was born over three years ago at the LPC (LHC Physics Centre), Fermilab and is based on earlier workshops held at the LPC and CLEO Experiment. As CMS transitioned from construction to the data taking mode, the nature of earlier training also evolved to include more of analysis tools, software tutorials and physics analysis. This effort epitomized as CMSDAS has proven to be a key for the new and young physicists to jump start and contribute to the physics goals of CMS by looking for new physics with the collision data. With over 400 physicists trained in six CMSDAS around the globe, CMS is trying to engage the collaboration in its discovery potential and maximize physics output. As a bigger goal, CMS is striving to nurture and increase engagement of the myriad talents, in the development of physics, service, upgrade, education of those new to CMS and the career development of younger members. An extension of the concept to the dedicated software and hardware schools is also planned, keeping in mind the ensuing upgrade phase.

  17. CMS Analysis School Model

    Energy Technology Data Exchange (ETDEWEB)

    Malik, S. [Nebraska U.; Shipsey, I. [Purdue U.; Cavanaugh, R. [Illinois U., Chicago; Bloom, K. [Nebraska U.; Chan, Kai-Feng [Taiwan, Natl. Taiwan U.; D' Hondt, J. [Vrije U., Brussels; Klima, B. [Fermilab; Narain, M. [Brown U.; Palla, F. [INFN, Pisa; Rolandi, G. [CERN; Schörner-Sadenius, T. [DESY

    2014-01-01

    To impart hands-on training in physics analysis, CMS experiment initiated the concept of CMS Data Analysis School (CMSDAS). It was born over three years ago at the LPC (LHC Physics Centre), Fermilab and is based on earlier workshops held at the LPC and CLEO Experiment. As CMS transitioned from construction to the data taking mode, the nature of earlier training also evolved to include more of analysis tools, software tutorials and physics analysis. This effort epitomized as CMSDAS has proven to be a key for the new and young physicists to jump start and contribute to the physics goals of CMS by looking for new physics with the collision data. With over 400 physicists trained in six CMSDAS around the globe, CMS is trying to engage the collaboration in its discovery potential and maximize physics output. As a bigger goal, CMS is striving to nurture and increase engagement of the myriad talents, in the development of physics, service, upgrade, education of those new to CMS and the career development of younger members. An extension of the concept to the dedicated software and hardware schools is also planned, keeping in mind the ensuing upgrade phase.

  18. CMS geometry through 2020

    International Nuclear Information System (INIS)

    Osborne, I; Brownson, E; Eulisse, G; Jones, C D; Sexton-Kennedy, E; Lange, D J

    2014-01-01

    CMS faces real challenges with upgrade of the CMS detector through 2020 and beyond. One of the challenges, from the software point of view, is managing upgrade simulations with the same software release as the 2013 scenario. We present the CMS geometry description software model, its integration with the CMS event setup and core software. The CMS geometry configuration and selection is implemented in Python. The tools collect the Python configuration fragments into a script used in CMS workflow. This flexible and automated geometry configuration allows choosing either transient or persistent version of the same scenario and specific version of the same scenario. We describe how the geometries are integrated and validated, and how we define and handle different geometry scenarios in simulation and reconstruction. We discuss how to transparently manage multiple incompatible geometries in the same software release. Several examples are shown based on current implementation assuring consistent choice of scenario conditions. The consequences and implications for multiple/different code algorithms are discussed.

  19. CMS Program Statistics

    Data.gov (United States)

    U.S. Department of Health & Human Services — The CMS Office of Enterprise Data and Analytics has developed CMS Program Statistics, which includes detailed summary statistics on national health care, Medicare...

  20. CMS Drug Spending

    Data.gov (United States)

    U.S. Department of Health & Human Services — CMS has released several information products that provide spending information for prescription drugs in the Medicare and Medicaid programs. The CMS Drug Spending...

  1. CMS Awards

    CERN Multimedia

    2004-01-01

    Ali Mohammad Rafiee receives the CMS Gold Award from Michel Della Negra of CMS. As part of the fifth annual CMS Awards, Iranian contractor HEPCO, located in Arak, an industrial town 200 km west of Tehran, received their Gold Award in a ceremony held on 14 June 2004 (the other award winners were reported in bulletin 13/2004). The Awards are given each year to a small number of the approximately one thousand contractors working on the CMS project. Gold Awards are given for outstanding technical achievement in work carried out for the detector. HEPCO received the Award for the excellent quality of their work in constructing two 25 tonne support tables, two 75 tonne shields (FCS) and eight supporting brackets to lower the HF into the cavern. Welds and machining obtained tolerances that were very difficult in structures of that size. Mr. A. M. Rafiee, the General Manager of the company, acknowledged the benefits of this collaboration, and thanked the efforts and skills of the many staff involved.

  2. The IBL Readout System

    CERN Document Server

    Dopke, J; The ATLAS collaboration; Flick, T; Gabrielli, A; Kugel, A; Maettig, P; Morettini, P; Polini, A; Schroer, N

    2010-01-01

    The first upgrade for the ATLAS pixel detector will be an additional layer, which is called IBL (Insertable B-Layer). To readout this new layer having new electronics assembled an update of the readout electronics is necessary. The aim is to develop a system which is capable to read out at a higher bandwidth and also compatible with the existing system to be integrated into it. The talk will describe the necessary development to reach a new readout system, concentrating on the requirements of a newly designed Back of Crate card as the optical interface in the counting room.

  3. The IBL Readout System

    CERN Document Server

    Dopke, J; Flick, T; Gabrielli, A; Kugel, A; Maettig, P; Morettini, P; Polini, A; Schroer, N

    2011-01-01

    The first upgrade for the ATLAS Pixel Detector will be an additional layer, which is called IBL (Insertable B-Layer). To readout this new layer, having new electronics, an update of the readout electronics is necessary. The aim is to develop a system which is capable to read out at a higher bandwidth, but also compatible with the existing system to be integrated into it. This paper will describe the necessary development to reach a new readout system, concentrating on the requirements of a newly designed Back of Crate card as the optical interface in the counting room.

  4. CMS computing support at JINR

    International Nuclear Information System (INIS)

    Golutvin, I.; Koren'kov, V.; Lavrent'ev, A.; Pose, R.; Tikhonenko, E.

    1998-01-01

    Participation of JINR specialists in the CMS experiment at LHC requires a wide use of computer resources. In the context of JINR activities in the CMS Project hardware and software resources have been provided for full participation of JINR specialists in the CMS experiment; the JINR computer infrastructure was made closer to the CERN one. JINR also provides the informational support for the CMS experiment (web-server http://sunct2.jinr.dubna.su). Plans for further CMS computing support at JINR are stated

  5. Beam Test Results for Single- and Double-Sided Silicon Detector Prototypes of the CMS Central Detector

    CERN Document Server

    Adriani, O

    1997-01-01

    We report the results of two beam tests performed in July and September 1995 at CERN using silicon microstrip detectors of various types: single sided, double sided with small angle stereo strips, double sided with orthogonal strips, double sided with pads. For the read-out electronics use was made of Preshape32, Premux128 and VA1 chips. The signal to noise ratio and the resolution of the detectors was studied for different incident angles of the incoming particles and for different values of the detector bias voltage. The goal of these tests was to check and improve the performances of the prototypes for the CMS Central Detector.

  6. CMS Tracker Readout Prototype Front-End Driver PCI Mezzanine Card (Mk1) (connector side)

    CERN Multimedia

    J.Coughlan

    1998-01-01

    The tracking system of the CMS detector at the LHC employs Front End Driver (FED) cards to digitise, buffer and sparsify analogue data arriving via optical links from on detector pipeline chips. This paper describes a prototype version of the FED based upon the popular commercial PCI bus Mezzanine Card (PMC) form factor. The FED-PMC consists of an 8 channel, 9 bit ADC, card, providing a 1 MByte data buffer and operating at the LHC design frequency of 40 MHz. The core of the card is a re-programmable FPGA which allows the functionality of the card to be conveniently modified. The card is supplied with a comprehensive library of C routines.The PMC form factor allows the card to be plugged onto a wide variety of processor carrier boards and even directly into PCI based PCs. The flexibility of the FPGA based design permits the card to be used in a variety of ADC based applications.

  7. LHCb: Fast Readout Control for the upgraded readout architecture of the LHCb experiment at CERN

    CERN Multimedia

    Alessio, F

    2013-01-01

    The LHCb experiment at CERN has proposed an upgrade towards a full 40 MHz readout system in order to run between five and ten times its initial design luminosity with an upgraded LHCb detector. As a consequence, the various LHCb sub-systems in the readout architecture will be upgraded to cope with higher sub-detector occupancies, higher rate, and higher readout load. The new architecture, new functionalities, and the first hardware implementation of a new LHCb Readout Control system (commonly referred to as S-TFC) for the upgraded LHCb experiment is here presented. Our attention is focused in describing solutions for the distribution of clock and timing information to control the entire upgraded readout architecture by profiting of a bidirectional optical network and powerful FPGAs, including a real-time mechanism to synchronize the entire system. Solutions and implementations are presented, together with first results on the simulation and the validation of the system.

  8. Installation and Commissioning of the CMS Hadron Forward Calorimeters Phase I Upgrade

    CERN Document Server

    Onel, Yasar

    2017-01-01

    The final phase of the CMS Hadron Forward Calorimeters Phase I upgrade was performed during the Extended Year End Technical Stop of 2016-2017. In the framework of the upgrade, the PMT boxes were reworked to implement two channel readout in order to exploit the benefits of the multi-anode PMTs in background tagging and signal recovery. The front-end electronics was also being upgraded to QIE10-based electronics which will implement larger dynamic range and a 6-bit TDC to provide additional handles to eliminate the background. Following this major upgrade, the Hadron Forward Calorimeters are being commissioned for operation readiness in 2017. Here we describe the details and the components of the upgrade, and discuss the operational experience and results obtained during the upgrade and commissioning.

  9. Readout ASIC for ILC-FPCCD vertex detector

    International Nuclear Information System (INIS)

    Takubo, Yosuke; Miyamoto, Akiya; Ikeda, Hirokazu; Yamamoto, Hitoshi; Itagaki, Kennosuke; Nagamine, Tadashi; Sugimoto, Yasuhiro

    2010-01-01

    The concept of FPCCD (Fine Pixel CCD) whose pixel size is 5x5μm 2 has been proposed as vertex detector at ILC. Since FPCCD has 128 x20,000 pixels in one readout channel, its readout poses a considerable challenge. We have developed a prototype of readout ASIC to readout the large number of pixels during the inter-train gap of the ILC beam. In this paper, we report the design and performance of the readout ASIC.

  10. Novel Trigger-Capable Modules for the Future CMS Tracking Detector and Inclusive Top Quark Pair Production Cross Section at $\\sqrt{s} = 13$ TeV

    CERN Document Server

    Harb, Ali; Mussgiller, Andreas

    2017-01-01

    This work covers two important aspects in the field of high-energy physics; detector development and physics data analysis. The first part of this thesis is devoted to the detector development activities for the Phase-II upgrade of the Compact Muon Solenoid (CMS) experiment’s outer tracking detector. To cope with the increased luminosity during the high-luminosity era of the Large Hadron Collider (LHC), it is foreseen to replace the existing tracking system of CMS with an entirely new system. Owing to a novel module concept called the $p_T$–module, the upgraded tracking system will be able to provide first level trigger information by means of an on-board momentum discrimination logic. This will be achieved using a new readout chip, the so-called CMS Binary Chip (CBC). The very first test beam measurement using $p_T$ –module prototypes, equipped with the CBC chip is presented and discussed. The obtained results serve as a proof-of-concept for such modules and shows that the CBC performs as expected. In...

  11. Pharmacokinetics of Colistin Methansulphonate (CMS) and Colistin after CMS Nebulisation in Baboon Monkeys.

    Science.gov (United States)

    Marchand, Sandrine; Bouchene, Salim; de Monte, Michèle; Guilleminault, Laurent; Montharu, Jérôme; Cabrera, Maria; Grégoire, Nicolas; Gobin, Patrice; Diot, Patrice; Couet, William; Vecellio, Laurent

    2015-10-01

    The objective of this study was to compare two different nebulizers: Eflow rapid® and Pari LC star® by scintigraphy and PK modeling to simulate epithelial lining fluid concentrations from measured plasma concentrations, after nebulization of CMS in baboons. Three baboons received CMS by IV infusion and by 2 types of aerosols generators and colistin by subcutaneous infusion. Gamma imaging was performed after nebulisation to determine colistin distribution in lungs. Blood samples were collected during 9 h and colistin and CMS plasma concentrations were measured by LC-MS/MS. A population pharmacokinetic analysis was conducted and simulations were performed to predict lung concentrations after nebulization. Higher aerosol distribution into lungs was observed by scintigraphy, when CMS was nebulized with Pari LC® star than with Eflow Rapid® nebulizer. This observation was confirmed by the fraction of CMS deposited into the lung (respectively 3.5% versus 1.3%).CMS and colistin simulated concentrations in epithelial lining fluid were higher after using the Pari LC star® than the Eflow rapid® system. A limited fraction of CMS reaches lungs after nebulization, but higher colistin plasma concentrations were measured and higher intrapulmonary colistin concentrations were simulated with the Pari LC Star® than with the Eflow Rapid® system.

  12. Opportunistic resource usage in CMS

    International Nuclear Information System (INIS)

    Kreuzer, Peter; Hufnagel, Dirk; Dykstra, D; Gutsche, O; Tadel, M; Sfiligoi, I; Letts, J; Wuerthwein, F; McCrea, A; Bockelman, B; Fajardo, E; Linares, L; Wagner, R; Konstantinov, P; Blumenfeld, B; Bradley, D

    2014-01-01

    CMS is using a tiered setup of dedicated computing resources provided by sites distributed over the world and organized in WLCG. These sites pledge resources to CMS and are preparing them especially for CMS to run the experiment's applications. But there are more resources available opportunistically both on the GRID and in local university and research clusters which can be used for CMS applications. We will present CMS' strategy to use opportunistic resources and prepare them dynamically to run CMS applications. CMS is able to run its applications on resources that can be reached through the GRID, through EC2 compliant cloud interfaces. Even resources that can be used through ssh login nodes can be harnessed. All of these usage modes are integrated transparently into the GlideIn WMS submission infrastructure, which is the basis of CMS' opportunistic resource usage strategy. Technologies like Parrot to mount the software distribution via CVMFS and xrootd for access to data and simulation samples via the WAN are used and will be described. We will summarize the experience with opportunistic resource usage and give an outlook for the restart of LHC data taking in 2015.

  13. CMS Data Analysis School Model

    CERN Document Server

    Malik, Sudhir; Cavanaugh, R; Bloom, K; Chan, Kai-Feng; D'Hondt, J; Klima, B; Narain, M; Palla, F; Rolandi, G; Schörner-Sadenius, T

    2014-01-01

    To impart hands-on training in physics analysis, CMS experiment initiated the  concept of CMS Data Analysis School (CMSDAS). It was born three years ago at the LPC (LHC Physics Center), Fermilab and is based on earlier workshops held at the LPC and CLEO Experiment. As CMS transitioned from construction to the data taking mode, the nature of earlier training also evolved to include more of analysis tools, software tutorials and physics analysis. This effort epitomized as CMSDAS has proven to be a key for the new and young physicists to jump start and contribute to the physics goals of CMS by looking for new physics with the collision data. With over 400 physicists trained in six CMSDAS around the globe , CMS is trying to  engage the collaboration discovery potential and maximize the physics output. As a bigger goal, CMS is striving to nurture and increase engagement of the myriad talents of CMS, in the development of physics, service, upgrade, education of those new to CMS and the caree...

  14. Development of a Timepix3 readout system based on the Merlin readout system

    International Nuclear Information System (INIS)

    Crevatin, G.; Carrato, S.; Horswell, I.; Omar, D.; Tartoni, N.; Cautero, G.

    2015-01-01

    Timepix3 chip is a new ASIC specifically designed to readout hybrid pixel detectors. The main purpose of Timepix3 is to measure the time of arrival of events. This characteristic can be exploited very effectively to develop detectors for time resolved experiments at synchrotron radiation facilities. In order to investigate how the ASIC can be applied to synchrotron experiments the Merlin readout system, developed at Diamond for the Medipix3 ASIC, has been adapted to readout the Timepix3 ASIC. The first tests of the ASIC with pulse injection and with alpha particles show that its behaviour is consistent with its nominal characteristics

  15. CMS Comic Book Brochure

    CERN Document Server

    2006-01-01

    To raise students' awareness of what the CMS detector is, how it was constructed and what it hopes to find. Titled "CMS Particle Hunter," this colorful comic book style brochure explains to young budding scientists and science enthusiasts in colorful animation how the CMS detector was made, its main parts, and what scientists hope to find using this complex tool.

  16. Search for SUSY in same-sign di-lepton events with the CMS detector

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Matthias

    2012-07-15

    In this thesis a search for new physics is presented, based on events with two isolated same-sign leptons (muons and electrons), jets, and missing transverse energy. The analyzed data corresponds to an integrated luminosity of 1.1 fb{sup -1} and is collected with the CMS detector in proton-proton collisions at the LHC with a center-of-mass energy of 7 TeV. A counting experiment is established by developing an event selection in order to select signal events in three different channels ({mu}{mu}, e{mu} and ee), while rejecting the Standard Model background as efficiently as possible. Standard Model background contributions are classified into several categories and estimated using different techniques. A total of 7 events is observed in data, being in agreement with the Standard Model background prediction of 11{+-}1(stat.){+-}2.7(syst.) events. Hence, no evidence for new physics is found. The observations are utilized to constrain the cMSSM by setting upper exclusion limits on possible signal contributions. The technical part of this theses contributes to the planned upgrade of the CMS experiment, by giving a motivation for a certain readout design of the hadronic calorimeter, in order to improve the performance of the detector in future. (orig.)

  17. Search for SUSY in same-sign di-lepton events with the CMS detector

    International Nuclear Information System (INIS)

    Stein, Matthias

    2012-07-01

    In this thesis a search for new physics is presented, based on events with two isolated same-sign leptons (muons and electrons), jets, and missing transverse energy. The analyzed data corresponds to an integrated luminosity of 1.1 fb -1 and is collected with the CMS detector in proton-proton collisions at the LHC with a center-of-mass energy of 7 TeV. A counting experiment is established by developing an event selection in order to select signal events in three different channels (μμ, eμ and ee), while rejecting the Standard Model background as efficiently as possible. Standard Model background contributions are classified into several categories and estimated using different techniques. A total of 7 events is observed in data, being in agreement with the Standard Model background prediction of 11±1(stat.)±2.7(syst.) events. Hence, no evidence for new physics is found. The observations are utilized to constrain the cMSSM by setting upper exclusion limits on possible signal contributions. The technical part of this theses contributes to the planned upgrade of the CMS experiment, by giving a motivation for a certain readout design of the hadronic calorimeter, in order to improve the performance of the detector in future. (orig.)

  18. Performance of new radiation tolerant thin n-in-p Silicon pixel sensors for the CMS experiment at High Luminosity LHC

    CERN Document Server

    Dalla Betta, G.F; Darbo, G; Dinardo, Mauro; Giacomini, G; Menasce, Dario; Meschini, Marco; Messineo, Alberto; Moroni, Luigi; Rivera, Ryan Allen; Ronchin, S; Uplegger, Lorenzo; Viliani, Lorenzo; Zoi, Irene; Zuolo, Davide

    2017-01-01

    The High Luminosity upgrade of the CERN-LHC (HL-LHC) demands for a new high-radiation tolerant solid-state pixel sensor capable of surviving fluencies up to a few 10$^{16}$ particles/cm$^2$ at $\\sim$3 cm from the interaction point. To this extent the INFN ATLAS-CMS joint research activity in collaboration with Fondazione Bruno Kessler-FBK, is aiming at the development of thin n-in-p type pixel sensors for the HL-LHC. The R and D covers both planar and single-sided 3D columnar pixel devices made with the Si-Si Direct Wafer Bonding technique, which allows for the production of sensors with 100~$\\mu {\\rm m}$ and 130~$\\mu {\\rm m}$ active thickness for planars, and 130~$\\mu {\\rm m}$ for 3D sensors, the thinnest ones ever produced so far. First prototypes of hybrid modules bump-bonded to the present CMS readout chip have been tested in beam tests. Preliminary results on their performance before and after irradiation are presented.

  19. Performance of the CMS 2S $p_T$ module prototype using CBC2 readout at beam tests

    CERN Document Server

    Roy Chowdhury, Suvankar

    2017-01-01

    As the LHC will enter into its high luminosity phase\\,(HL-LHC), operating at a luminosity of $5\\rm{\\mbox{-}}7.5\\times10^{34}~\\rm cm^{-2}\\rm s^{-1}$, the CMS experiment will replace the Run 2 tracker with a new one which will be able to sustain the increased number of collisions per bunch crossing, which can be as high as 200. The tracker information will be used in the Level-1 trigger to reject low $p_T$ tracks. In this paper, the performance of the modules of the proposed outer tracker in test beams is reported.

  20. CMS analysis operations

    International Nuclear Information System (INIS)

    Andreeva, J; Maier, G; Spiga, D; Calloni, M; Colling, D; Fanzago, F; D'Hondt, J; Maes, J; Van Mulders, P; Villella, I; Klem, J; Letts, J; Padhi, S; Sarkar, S

    2010-01-01

    During normal data taking CMS expects to support potentially as many as 2000 analysis users. Since the beginning of 2008 there have been more than 800 individuals who submitted a remote analysis job to the CMS computing infrastructure. The bulk of these users will be supported at the over 40 CMS Tier-2 centres. Supporting a globally distributed community of users on a globally distributed set of computing clusters is a task that requires reconsidering the normal methods of user support for Analysis Operations. In 2008 CMS formed an Analysis Support Task Force in preparation for large-scale physics analysis activities. The charge of the task force was to evaluate the available support tools, the user support techniques, and the direct feedback of users with the goal of improving the success rate and user experience when utilizing the distributed computing environment. The task force determined the tools needed to assess and reduce the number of non-zero exit code applications submitted through the grid interfaces and worked with the CMS experiment dashboard developers to obtain the necessary information to quickly and proactively identify issues with user jobs and data sets hosted at various sites. Results of the analysis group surveys were compiled. Reference platforms for testing and debugging problems were established in various geographic regions. The task force also assessed the resources needed to make the transition to a permanent Analysis Operations task. In this presentation the results of the task force will be discussed as well as the CMS Analysis Operations plans for the start of data taking.

  1. Upgrade of the TOTEM DAQ using the Scalable Readout System (SRS)

    International Nuclear Information System (INIS)

    Quinto, M; Cafagna, F; Fiergolski, A; Radicioni, E

    2013-01-01

    The main goals of the TOTEM Experiment at the LHC are the measurements of the elastic and total p-p cross sections and the studies of the diffractive dissociation processes. At LHC, collisions are produced at a rate of 40 MHz, imposing strong requirements for the Data Acquisition Systems (DAQ) in terms of trigger rate and data throughput. The TOTEM DAQ adopts a modular approach that, in standalone mode, is based on VME bus system. The VME based Front End Driver (FED) modules, host mezzanines that receive data through optical fibres directly from the detectors. After data checks and formatting are applied in the mezzanine, data is retransmitted to the VME interface and to another mezzanine card plugged in the FED module. The VME bus maximum bandwidth limits the maximum first level trigger (L1A) to 1 kHz rate. In order to get rid of the VME bottleneck and improve scalability and the overall capabilities of the DAQ, a new system was designed and constructed based on the Scalable Readout System (SRS), developed in the framework of the RD51 Collaboration. The project aims to increase the efficiency of the actual readout system providing higher bandwidth, and increasing data filtering, implementing a second-level trigger event selection based on hardware pattern recognition algorithms. This goal is to be achieved preserving the maximum back compatibility with the LHC Timing, Trigger and Control (TTC) system as well as with the CMS DAQ. The obtained results and the perspectives of the project are reported. In particular, we describe the system architecture and the new Opto-FEC adapter card developed to connect the SRS with the FED mezzanine modules. A first test bench was built and validated during the last TOTEM data taking period (February 2013). Readout of a set of 3 TOTEM Roman Pot silicon detectors was carried out to verify performance in the real LHC environment. In addition, the test allowed a check of data consistency and quality

  2. Evacuation drill at CMS

    CERN Multimedia

    Niels Dupont-Sagorin and Christoph Schaefer

    2012-01-01

    Training personnel, including evacuation guides and shifters, checking procedures, improving collaboration with the CERN Fire Brigade: the first real-life evacuation drill at CMS took place on Friday 3 February from 12p.m. to 3p.m. in the two caverns located at Point 5 of the LHC.   CERN personnel during the evacuation drill at CMS. Evacuation drills are required by law and have to be organized periodically in all areas of CERN, both above and below ground. The last drill at CMS, which took place in June 2007, revealed some desiderata, most notably the need for a public address system. With this equipment in place, it is now possible to broadcast audio messages from the CMS control room to the underground areas.   The CMS Technical Coordination Team and the GLIMOS have focused particularly on preparing collaborators for emergency situations by providing training and organizing regular safety drills with the HSE Unit and the CERN Fire Brigade. This Friday, the practical traini...

  3. CMS Space Monitoring

    Science.gov (United States)

    Ratnikova, N.; Huang, C.-H.; Sanchez-Hernandez, A.; Wildish, T.; Zhang, X.

    2014-06-01

    During the first LHC run, CMS stored about one hundred petabytes of data. Storage accounting and monitoring help to meet the challenges of storage management, such as efficient space utilization, fair share between users and groups and resource planning. We present a newly developed CMS space monitoring system based on the storage metadata dumps produced at the sites. The information extracted from the storage dumps is aggregated and uploaded to a central database. A web based data service is provided to retrieve the information for a given time interval and a range of sites, so it can be further aggregated and presented in the desired format. The system has been designed based on the analysis of CMS monitoring requirements and experiences of the other LHC experiments. In this paper, we demonstrate how the existing software components of the CMS data placement system, PhEDEx, have been re-used, dramatically reducing the development effort.

  4. CMS Space Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Ratnikova, N. [Fermilab; Huang, C.-H. [Fermilab; Sanchez-Hernandez, A. [CINVESTAV, IPN; Wildish, T. [Princeton U.; Zhang, X. [Beijing, Inst. High Energy Phys.

    2014-01-01

    During the first LHC run, CMS stored about one hundred petabytes of data. Storage accounting and monitoring help to meet the challenges of storage management, such as efficient space utilization, fair share between users and groups and resource planning. We present a newly developed CMS space monitoring system based on the storage metadata dumps produced at the sites. The information extracted from the storage dumps is aggregated and uploaded to a central database. A web based data service is provided to retrieve the information for a given time interval and a range of sites, so it can be further aggregated and presented in the desired format. The system has been designed based on the analysis of CMS monitoring requirements and experiences of the other LHC experiments. In this paper, we demonstrate how the existing software components of the CMS data placement system, PhEDEx, have been re-used, dramatically reducing the development effort.

  5. Single-Readout High-Density Memristor Crossbar

    KAUST Repository

    Zidan, M. A.

    2016-01-07

    High-density memristor-crossbar architecture is a very promising technology for future computing systems. The simplicity of the gateless-crossbar structure is both its principal advantage and the source of undesired sneak-paths of current. This parasitic current could consume an enormous amount of energy and ruin the readout process. We introduce new adaptive-threshold readout techniques that utilize the locality and hierarchy properties of the computer-memory system to address the sneak-paths problem. The proposed methods require a single memory access per pixel for an array readout. Besides, the memristive crossbar consumes an order of magnitude less power than state-of-the-art readout techniques.

  6. Single-Readout High-Density Memristor Crossbar

    KAUST Repository

    Zidan, M. A.; Omran, Hesham; Naous, Rawan; Salem, Ahmed Sultan; Fahmy, H. A. H.; Lu, W. D.; Salama, Khaled N.

    2016-01-01

    High-density memristor-crossbar architecture is a very promising technology for future computing systems. The simplicity of the gateless-crossbar structure is both its principal advantage and the source of undesired sneak-paths of current. This parasitic current could consume an enormous amount of energy and ruin the readout process. We introduce new adaptive-threshold readout techniques that utilize the locality and hierarchy properties of the computer-memory system to address the sneak-paths problem. The proposed methods require a single memory access per pixel for an array readout. Besides, the memristive crossbar consumes an order of magnitude less power than state-of-the-art readout techniques.

  7. Status and future prospects of the Muon Drift Tubes System of CMS

    International Nuclear Information System (INIS)

    Masetti, G.

    2017-01-01

    A key component of the CMS (Compact Muon Solenoid) experiment is its muon system. The tracking and triggering of muons in the central part relies on Drift Tube (DT) chambers. In 2013 and 2014 a number of improvements and upgrades were implemented, in particular concerning the readout and trigger electronics. The increase of luminosity expected by LHC will impose several constraints for rate reduction while maintaining high efficiency in the CMS Level 1 trigger system. In order to exploit the muon detector redundancy, a new trigger system has been designed. The TwinMux system is the early layer of the muon barrel region that combines the primitives information from different subdetectors: DT, Resistive Plate Chambers (RPC) and Outer Hadron Calorimeter (HO). Regarding the long term operation of the DT system, in order to cope with up to a factor 2 nominal LHC luminosity, several improvements will be implemented. The in-chamber local electronics will be modified to cope with the new rate and radiation environment. This paper will present, along with the main system improvements implemented in the system, the first performance results from data collected at 13 TeV center-of-mass energy during 2016, confirming the satisfactory operation of both DT performance and the TwinMux system. A review of the present status and plans for the DT system upgrades will be also described.

  8. Simulation of the Dynamic Inefficiency of the CMS Pixel Detector

    CERN Document Server

    INSPIRE-00380273

    2015-05-07

    The Pixel Detector is the innermost part of the CMS Tracker. It therefore has to prevail in the harshest environment in terms of particle fluence and radiation. There are several mechanisms that may decrease the efficiency of the detector. These are mainly caused by data acquisition (DAQ) problems and/or Single Event Upsets (SEU). Any remaining efficiency loss is referred to as the dynamic inefficiency. It is caused by various mechanisms inside the Readout Chip (ROC) and depends strongly on the data occupancy. In the 2012 data, at high values of instantaneous luminosity the inefficiency reached 2\\% (in the region closest to the interaction point) which is not negligible. In the 2015 run higher instantaneous luminosity is expected, which will result in lower efficiencies; therefore this effect needs to be understood and simulated. A data-driven method has been developed to simulate dynamic inefficiency, which has been shown to successfully simulate the effects.

  9. High Granularity Calorimeter for the CMS Endcap at HL-LHC

    CERN Document Server

    Rusack, Roger

    2016-01-01

    Calorimetry at the High Luminosity LHC (HL-LHC) faces two enormous challenges, particularly in the forward direction radiation tolerance and unprecedented in-time event pileup. To meet these challenges, the CMS experiment has decided to construct a High Granularity Calorimeter (HGCAL), featuring an unprecedented transverse and longitudinal segmentation in a collider detector, both for electromagnetic and hadronic compartments. This will enable the optimal utilization of the Particle Flow Algorithms, with which the fine structure of showers can be measured and used to enhance particle identification, energy resolution and pileup rejection. The majority of the HGCAL will be based on robust and cost-effective hexagonal silicon sensors with ~1cm^2 or 0.5cm^2 hexagonal cell size, with the final 5 interaction lengths of the hadronic compartment being based on highly segmented plastic scintillator with SiPM readout. Here, we present an overview of the HGCAL project, including the motivation, engineering design, rea...

  10. International Masterclass at CMS

    CERN Multimedia

    Lapka, M

    2012-01-01

    The CMS collaboration welcomed a class of French high school students to the CERN facility in Meyrin, Switzerland on the 12 of March, 2012. Students spent the day meeting with physicists, hearing talks, asking questions, and participating in a hands-on exercise using real data collected by the CMS experiment on the Large Hadron Colider. Talks and other resources are available here: http://ippog-dev.web.cern.ch/resources/2012/ippog-international-masterclass-2012-cms

  11. CMS Industries awarded gold, crystal

    CERN Multimedia

    2006-01-01

    The CMS collaboration honoured 10 of its top suppliers in the seventh annual awards ceremony The representatives of the firms that recieved the CMS Gold and Crystal Awards stand with their awards after the ceremony. The seventh annual CMS Awards ceremony was held on Monday 13 March to recognize the industries that have made substantial contributions to the construction of the collaboration's detector. Nine international firms received Gold Awards, and General Tecnica of Italy received the prestigious Crystal Award. Representatives from the companies attended the ceremony during the plenary session of CMS week. 'The role of CERN, its machines and experiments, beyond particle physics is to push the development of equipment technologies related to high-energy physics,'said CMS Awards Coordinator Domenico Campi. 'All of these industries must go beyond the technologies that are currently available.' Without the involvement of good companies over the years, the construction of the CMS detector wouldn't be possible...

  12. Detector Performance and Upgrade Plans of the Pixel Luminosity Telescope for Online per-Bunch Luminosity Measurement at CMS

    CERN Document Server

    CMS Collaboration

    2017-01-01

    The Pixel Luminosity Telescope (PLT) is a dedicated system for luminosity measurement at the CMS experiment using silicon pixel sensors. It was installed during LS1 and has been providing luminosity measurements throughout Run 2. The online bunch-by-bunch luminosity measurement employs the "fast-or" capability of the pixel readout chip (PSI46) to quickly identify likely tracks at the full 40MHz interaction rate. In addition, the full pixel information is read out at a lower rate, allowing for more detailed offline analysis. In this talk, we will present details of the commissioning, performance and operational history of the currently installed hardware and upgrade plans for LS2.

  13. CMS MANAGEMENT MEETINGS

    CERN Multimedia

    2010-01-01

    The Agendas and Minutes of the Management Board meetings are accessible to CMS members at: http://indico.cern.ch/categoryDisplay.py?categId=223 The Agendas and Minutes of the Collaboration Board meetings are accessible to CMS members at: http://indico.cern.ch/categoryDisplay.py?categId=174

  14. CERN Researchers' Night @ CMS + TOTEM

    CERN Multimedia

    Hoch, Michael

    2011-01-01

    Young researchers' shifter training at CMS; • Introduction talk with discussion, • CMS control room shadowing the shifters • TOTEM control room introduction and discusson • Scientific poster work shop and presentation • Science Art installations ‘Faces of CMS’ & ‘Science Cloud’ • CMS Shift diploma presentation

  15. Quantitative proteomic analysis of CMS-related changes in Honglian CMS rice anther.

    Science.gov (United States)

    Sun, Qingping; Hu, Chaofeng; Hu, Jun; Li, Shaoqing; Zhu, Yingguo

    2009-10-01

    Honglian (HL) cytoplasmic male sterility (CMS) is one of the rice CMS types and has been widely used in hybrid rice production in China. The CMS line (Yuetai A, YTA) has a Yuetai B (maintainer line, YTB) nuclear genome, but has a rearranged mitochondrial (mt) genome consisting of Yuetai B. The fertility of hybrid (HL-6) was restored by restorer gene in nuclear genome of restorer line (9311). We used isotope-code affinity tag (ICAT) technology to perform the protein profiling of uninucleate stage rice anther and identify the CMS-HL related proteins. Two separate ICAT analyses were performed in this study: (1) anthers from YTA versus anthers from YTB, and (2) anthers from YTA versus anthers from HL-6. Based on the two analyses, a total of 97 unique proteins were identified and quantified in uninucleate stage rice anther under the error rate of less than 10%, of which eight proteins showed abundance changes of at least twofold between YTA and YTB. Triosephosphate isomerase, fructokinase II, DNA-binding protein GBP16 and ribosomal protein L3B were over-expressed in YTB, while oligopeptide transporter, floral organ regulator 1, kinase and S-adenosyl-L: -methionine synthetase were over-expressed in YTA. Reduction of the proteins associated with energy production and lesser ATP equivalents detected in CMS anther indicated that the low level of energy production played an important role in inducing CMS-HL.

  16. CMS MANAGEMENT MEETINGS

    CERN Multimedia

    The Agendas and Minutes of the Management Board meetings are accessible to CMS members at: http://indico.cern.ch/categoryDisplay.py?categId=223  The Agendas and Minutes of the Collaboration Board meetings are accessible to CMS members at: http://indico.cern.ch/categoryDisplay.py?categId=174 

  17. Debugging data transfers in CMS

    International Nuclear Information System (INIS)

    Bagliesi, G; Belforte, S; Bloom, K; Bockelman, B; Bonacorsi, D; Fisk, I; Flix, J; Hernandez, J; D'Hondt, J; Maes, J; Kadastik, M; Klem, J; Kodolova, O; Kuo, C-M; Letts, J; Magini, N; Metson, S; Piedra, J; Pukhaeva, N; Tuura, L

    2010-01-01

    The CMS experiment at CERN is preparing for LHC data taking in several computing preparation activities. In early 2007 a traffic load generator infrastructure for distributed data transfer tests was designed and deployed to equip the WLCG tiers which support the CMS virtual organization with a means for debugging, load-testing and commissioning data transfer routes among CMS computing centres. The LoadTest is based upon PhEDEx as a reliable, scalable data set replication system. The Debugging Data Transfers (DDT) task force was created to coordinate the debugging of the data transfer links. The task force aimed to commission most crucial transfer routes among CMS tiers by designing and enforcing a clear procedure to debug problematic links. Such procedure aimed to move a link from a debugging phase in a separate and independent environment to a production environment when a set of agreed conditions are achieved for that link. The goal was to deliver one by one working transfer routes to the CMS data operations team. The preparation, activities and experience of the DDT task force within the CMS experiment are discussed. Common technical problems and challenges encountered during the lifetime of the taskforce in debugging data transfer links in CMS are explained and summarized.

  18. Digital column readout architectures for hybrid pixel detector readout chips

    International Nuclear Information System (INIS)

    Poikela, T; Plosila, J; Westerlund, T; Buytaert, J; Campbell, M; Gaspari, M De; Llopart, X; Wyllie, K; Gromov, V; Kluit, R; Beuzekom, M van; Zappon, F; Zivkovic, V; Brezina, C; Desch, K; Fu, Y; Kruth, A

    2014-01-01

    In this paper, two digital column architectures suitable for sparse readout of data from a pixel matrix in trigger-less applications are presented. Each architecture reads out a pixel matrix of 256 x 256 pixels with a pixel pitch of 55 μm. The first architecture has been implemented in the Timepix3 chip, and this is presented together with initial measurements. Simulation results and measured data are compared. The second architecture has been designed for Velopix, a readout chip planned for the LHCb VELO upgrade. Unlike Timepix3, this has to be tolerant to radiation-induced single-event effects. Results from post-layout simulations are shown with the circuit architectures

  19. Compression module for the BCM1F microTCA raw data readout

    CERN Document Server

    Dostanic, Milica

    2017-01-01

    BCM1F is a diamond based detector and one of the luminometers and background monitors operated by the BRIL group, part of the CMS experiment. BCM1F's front-end produces analog signals which are digitized in a new microTCA back-end. An FPGA in the back-end part takes care of signal processing and stores raw data. The raw data readout has been improved by implementing a data compression module in the firmware. This module has allowed storing larger amount of data in short time intervals. The module has been implemented in VHDL, using a zero suppression algorithm: only data above a defined threshold is stored into memory, while the samples around the base line are discarded. Thanks to metadata, describing the suppressed data, the shape of input signals and time information are preserved. Tests with simulations and a pulse generator showed good results and proved that the module can achieve large compression factor.

  20. The CMS dataset bookkeeping service

    Science.gov (United States)

    Afaq, A.; Dolgert, A.; Guo, Y.; Jones, C.; Kosyakov, S.; Kuznetsov, V.; Lueking, L.; Riley, D.; Sekhri, V.

    2008-07-01

    The CMS Dataset Bookkeeping Service (DBS) has been developed to catalog all CMS event data from Monte Carlo and Detector sources. It provides the ability to identify MC or trigger source, track data provenance, construct datasets for analysis, and discover interesting data. CMS requires processing and analysis activities at various service levels and the DBS system provides support for localized processing or private analysis, as well as global access for CMS users at large. Catalog entries can be moved among the various service levels with a simple set of migration tools, thus forming a loose federation of databases. DBS is available to CMS users via a Python API, Command Line, and a Discovery web page interfaces. The system is built as a multi-tier web application with Java servlets running under Tomcat, with connections via JDBC to Oracle or MySQL database backends. Clients connect to the service through HTTP or HTTPS with authentication provided by GRID certificates and authorization through VOMS. DBS is an integral part of the overall CMS Data Management and Workflow Management systems.

  1. The CMS dataset bookkeeping service

    Energy Technology Data Exchange (ETDEWEB)

    Afaq, A; Guo, Y; Kosyakov, S; Lueking, L; Sekhri, V [Fermilab, Batavia, Illinois 60510 (United States); Dolgert, A; Jones, C; Kuznetsov, V; Riley, D [Cornell University, Ithaca, New York 14850 (United States)

    2008-07-15

    The CMS Dataset Bookkeeping Service (DBS) has been developed to catalog all CMS event data from Monte Carlo and Detector sources. It provides the ability to identify MC or trigger source, track data provenance, construct datasets for analysis, and discover interesting data. CMS requires processing and analysis activities at various service levels and the DBS system provides support for localized processing or private analysis, as well as global access for CMS users at large. Catalog entries can be moved among the various service levels with a simple set of migration tools, thus forming a loose federation of databases. DBS is available to CMS users via a Python API, Command Line, and a Discovery web page interfaces. The system is built as a multi-tier web application with Java servlets running under Tomcat, with connections via JDBC to Oracle or MySQL database backends. Clients connect to the service through HTTP or HTTPS with authentication provided by GRID certificates and authorization through VOMS. DBS is an integral part of the overall CMS Data Management and Workflow Management systems.

  2. The CMS dataset bookkeeping service

    International Nuclear Information System (INIS)

    Afaq, A; Guo, Y; Kosyakov, S; Lueking, L; Sekhri, V; Dolgert, A; Jones, C; Kuznetsov, V; Riley, D

    2008-01-01

    The CMS Dataset Bookkeeping Service (DBS) has been developed to catalog all CMS event data from Monte Carlo and Detector sources. It provides the ability to identify MC or trigger source, track data provenance, construct datasets for analysis, and discover interesting data. CMS requires processing and analysis activities at various service levels and the DBS system provides support for localized processing or private analysis, as well as global access for CMS users at large. Catalog entries can be moved among the various service levels with a simple set of migration tools, thus forming a loose federation of databases. DBS is available to CMS users via a Python API, Command Line, and a Discovery web page interfaces. The system is built as a multi-tier web application with Java servlets running under Tomcat, with connections via JDBC to Oracle or MySQL database backends. Clients connect to the service through HTTP or HTTPS with authentication provided by GRID certificates and authorization through VOMS. DBS is an integral part of the overall CMS Data Management and Workflow Management systems

  3. The CMS dataset bookkeeping service

    International Nuclear Information System (INIS)

    Afaq, Anzar; Dolgert, Andrew; Guo, Yuyi; Jones, Chris; Kosyakov, Sergey; Kuznetsov, Valentin; Lueking, Lee; Riley, Dan; Sekhri, Vijay

    2007-01-01

    The CMS Dataset Bookkeeping Service (DBS) has been developed to catalog all CMS event data from Monte Carlo and Detector sources. It provides the ability to identify MC or trigger source, track data provenance, construct datasets for analysis, and discover interesting data. CMS requires processing and analysis activities at various service levels and the DBS system provides support for localized processing or private analysis, as well as global access for CMS users at large. Catalog entries can be moved among the various service levels with a simple set of migration tools, thus forming a loose federation of databases. DBS is available to CMS users via a Python API, Command Line, and a Discovery web page interfaces. The system is built as a multi-tier web application with Java servlets running under Tomcat, with connections via JDBC to Oracle or MySQL database backends. Clients connect to the service through HTTP or HTTPS with authentication provided by GRID certificates and authorization through VOMS. DBS is an integral part of the overall CMS Data Management and Workflow Management systems

  4. A new dawn for CMS

    CERN Multimedia

    2007-01-01

    Supported by a gigantic crane and a factory-size room full of enthusiasm, the central barrel of CMS made its final journey underground on 28 February. The central section of the CMS detector starts its dramatic 10-hour descent underground.Several hours (and 100 metres) later, the massive barrel rests on the cavern floor. CMS scientists, journalists, photographers and members of the transport crew basked in the final rays of the 'solenoid-set' on 28 February as the central barrel of the CMS detector sinks below the horizon and began its ten-hour descent into the cavern 100 metres below. Thirteen metres long and weighing as much as five jumbo jets (1920 tonnes), the barrel is the largest of the 15 chunks of CMS detector that are being lowered one by one into the cavern. 'This is a challenging feat of engineering, as there are just 20 cm of leeway between the detector and the walls of the shaft,' said Austin Ball, Technical Coordinator of CMS. The section of the detector, which contains the solenoid of the magne...

  5. Frequency multiplexing for readout of spin qubits

    Energy Technology Data Exchange (ETDEWEB)

    Hornibrook, J. M.; Colless, J. I.; Mahoney, A. C.; Croot, X. G.; Blanvillain, S.; Reilly, D. J., E-mail: david.reilly@sydney.edu.au [ARC Centre of Excellence for Engineered Quantum Systems, School of Physics, University of Sydney, Sydney, NSW 2006 (Australia); Lu, H.; Gossard, A. C. [Materials Department, University of California, Santa Barbara, California 93106 (United States)

    2014-03-10

    We demonstrate a low loss, chip-level frequency multiplexing scheme for readout of scaled-up spin qubit devices. By integrating separate bias tees and resonator circuits on-chip for each readout channel, we realise dispersive gate-sensing in combination with charge detection based on two radio frequency quantum point contacts. We apply this approach to perform multiplexed readout of a double quantum dot in the few-electron regime and further demonstrate operation of a 10-channel multiplexing device. Limitations for scaling spin qubit readout to large numbers of multiplexed channels are discussed.

  6. Test beam demonstration of silicon microstrip modules with transverse momentum discrimination for the future CMS tracking detector

    Science.gov (United States)

    Adam, W.; Bergauer, T.; Brondolin, E.; Dragicevic, M.; Friedl, M.; Frühwirth, R.; Hoch, M.; Hrubec, J.; König, A.; Steininger, H.; Treberspurg, W.; Waltenberger, W.; Alderweireldt, S.; Beaumont, W.; Janssen, X.; Lauwers, J.; Van Mechelen, P.; Van Remortel, N.; Van Spilbeeck, A.; Beghin, D.; Brun, H.; Clerbaux, B.; De Lentdecker, G.; Delannoy, H.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Karapostoli, G.; Lenzi, T.; Léonard, A.; Luetic, J.; Maerschalk, T.; Marinov, A.; Postiau, N.; Randle-Conde, A.; Seva, T.; Vanlaer, P.; Vannerom, D.; Yonamine, R.; Wang, Q.; Yang, Y.; Zenoni, F.; Zhang, F.; Abu Zeid, S.; Blekman, F.; De Bruyn, I.; De Clercq, J.; D'Hondt, J.; Deroover, K.; Lowette, S.; Moortgat, S.; Moreels, L.; Python, Q.; Skovpen, K.; Van Mulders, P.; Van Parijs, I.; Bakhshiansohi, H.; Bondu, O.; Brochet, S.; Bruno, G.; Caudron, A.; Delaere, C.; Delcourt, M.; De Visscher, S.; Francois, B.; Giammanco, A.; Jafari, A.; Cabrera Jamoulle, J.; De Favereau De Jeneret, J.; Komm, M.; Krintiras, G.; Lemaitre, V.; Magitteri, A.; Mertens, A.; Michotte, D.; Musich, M.; Piotrzkowski, K.; Quertenmont, L.; Szilasi, N.; Vidal Marono, M.; Wertz, S.; Beliy, N.; Caebergs, T.; Daubie, E.; Hammad, G. H.; Härkönen, J.; Lampén, T.; Luukka, P.; Peltola, T.; Tuominen, E.; Tuovinen, E.; Eerola, P.; Baulieu, G.; Boudoul, G.; Caponetto, L.; Combaret, C.; Contardo, D.; Dupasquier, T.; Gallbit, G.; Lumb, N.; Mirabito, L.; Perries, S.; Vander Donckt, M.; Viret, S.; Agram, J.-L.; Andrea, J.; Bloch, D.; Bonnin, C.; Brom, J.-M.; Chabert, E.; Chanon, N.; Charles, L.; Conte, E.; Fontaine, J.-Ch.; Gross, L.; Hosselet, J.; Jansova, M.; Tromson, D.; Autermann, C.; Feld, L.; Karpinski, W.; Kiesel, K. M.; Klein, K.; Lipinski, M.; Ostapchuk, A.; Pierschel, G.; Preuten, M.; Rauch, M.; Schael, S.; Schomakers, C.; Schulz, J.; Schwering, G.; Wlochal, M.; Zhukov, V.; Pistone, C.; Fluegge, G.; Kuensken, A.; Pooth, O.; Stahl, A.; Aldaya, M.; Asawatangtrakuldee, C.; Beernaert, K.; Bertsche, D.; Contreras-Campana, C.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Gallo, E.; Garay Garcia, J.; Hansen, K.; Haranko, M.; Harb, A.; Hauk, J.; Keaveney, J.; Kalogeropoulos, A.; Kleinwort, C.; Lohmann, W.; Mankel, R.; Maser, H.; Mittag, G.; Muhl, C.; Mussgiller, A.; Pitzl, D.; Reichelt, O.; Savitskyi, M.; Schuetze, P.; Walsh, R.; Zuber, A.; Biskop, H.; Buhmann, P.; Centis-Vignali, M.; Garutti, E.; Haller, J.; Hoffmann, M.; Klanner, R.; Matysek, M.; Perieanu, A.; Scharf, Ch.; Schleper, P.; Schmidt, A.; Schwandt, J.; Sonneveld, J.; Steinbrück, G.; Vormwald, B.; Wellhausen, J.; Abbas, M.; Amstutz, C.; Barvich, T.; Barth, Ch.; Boegelspacher, F.; De Boer, W.; Butz, E.; Casele, M.; Colombo, F.; Dierlamm, A.; Freund, B.; Hartmann, F.; Heindl, S.; Husemann, U.; Kornmeyer, A.; Kudella, S.; Muller, Th.; Printz, M.; Simonis, H. J.; Steck, P.; Weber, M.; Weiler, Th.; Anagnostou, G.; Asenov, P.; Assiouras, P.; Daskalakis, G.; Kyriakis, A.; Loukas, D.; Paspalaki, L.; Siklér, F.; Veszprémi, V.; Bhardwaj, A.; Dalal, R.; Jain, G.; Ranjan, K.; Dutta, S.; Chowdhury, S. Roy; Bakhshiansohl, H.; Behnamian, H.; Khakzad, M.; Naseri, M.; Cariola, P.; Creanza, D.; De Palma, M.; De Robertis, G.; Fiore, L.; Franco, M.; Loddo, F.; Sala, G.; Silvestris, L.; Maggi, G.; My, S.; Selvaggi, G.; Albergo, S.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Saizu, M. A.; Tricomi, A.; Tuve, C.; Barbagli, G.; Brianzi, M.; Ciaranfi, R.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Latino, G.; Lenzi, P.; Meschini, M.; Paoletti, S.; Russo, L.; Scarlini, E.; Sguazzoni, G.; Strom, D.; Viliani, L.; Ferro, F.; Lo Vetere, M.; Robutti, E.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Malvezzi, S.; Manzoni, R. A.; Menasce, D.; Moroni, L.; Pedrini, D.; Azzi, P.; Bacchetta, N.; Bisello, D.; Dall'Osso, M.; Pozzobon, N.; Tosi, M.; De Canio, F.; Gaioni, L.; Manghisoni, M.; Nodari, B.; Riceputi, E.; Re, V.; Traversi, G.; Comotti, D.; Ratti, L.; Alunni Solestizi, L.; Biasini, M.; Bilei, G. M.; Cecchi, C.; Checcucci, B.; Ciangottini, D.; Fanò, L.; Gentsos, C.; Ionica, M.; Leonardi, R.; Manoni, E.; Mantovani, G.; Marconi, S.; Mariani, V.; Menichelli, M.; Modak, A.; Morozzi, A.; Moscatelli, F.; Passeri, D.; Placidi, P.; Postolache, V.; Rossi, A.; Saha, A.; Santocchia, A.; Storchi, L.; Spiga, D.; Androsov, K.; Azzurri, P.; Arezzini, S.; Bagliesi, G.; Basti, A.; Boccali, T.; Borrello, L.; Bosi, F.; Castaldi, R.; Ciampa, A.; Ciocci, M. A.; Dell'Orso, R.; Donato, S.; Fedi, G.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Magazzu, G.; Martini, L.; Mazzoni, E.; Messineo, A.; Moggi, A.; Morsani, F.; Palla, F.; Palmonari, F.; Raffaelli, F.; Rizzi, A.; Savoy-Navarro, A.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Bellan, R.; Costa, M.; Covarelli, R.; Da Rocha Rolo, M.; Demaria, N.; Rivetti, A.; Dellacasa, G.; Mazza, G.; Migliore, E.; Monteil, E.; Pacher, L.; Ravera, F.; Solano, A.; Fernandez, M.; Gomez, G.; Jaramillo Echeverria, R.; Moya, D.; Gonzalez Sanchez, F. J.; Vila, I.; Virto, A. L.; Abbaneo, D.; Ahmed, I.; Albert, E.; Auzinger, G.; Berruti, G.; Bianchi, G.; Blanchot, G.; Bonnaud, J.; Caratelli, A.; Ceresa, D.; Christiansen, J.; Cichy, K.; Daguin, J.; D'Auria, A.; Detraz, S.; Deyrail, D.; Dondelewski, O.; Faccio, F.; Frank, N.; Gadek, T.; Gill, K.; Honma, A.; Hugo, G.; Jara Casas, L. M.; Kaplon, J.; Kornmayer, A.; Kottelat, L.; Kovacs, M.; Krammer, M.; Lenoir, P.; Mannelli, M.; Marchioro, A.; Marconi, S.; Mersi, S.; Martina, S.; Michelis, S.; Moll, M.; Onnela, A.; Orfanelli, S.; Pavis, S.; Peisert, A.; Pernot, J.-F.; Petagna, P.; Petrucciani, G.; Postema, H.; Rose, P.; Tropea, P.; Troska, J.; Tsirou, A.; Vasey, F.; Vichoudis, P.; Verlaat, B.; Zwalinski, L.; Bachmair, F.; Becker, R.; di Calafiori, D.; Casal, B.; Berger, P.; Djambazov, L.; Donega, M.; Grab, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Lustermann, W.; Mangano, B.; Marionneau, M.; Martinez Ruiz del Arbol, P.; Masciovecchio, M.; Meinhard, M.; Perozzi, L.; Roeser, U.; Starodumov, A.; Tavolaro, V.; Wallny, R.; Zhu, D.; Amsler, C.; Bösiger, K.; Caminada, L.; Canelli, F.; Chiochia, V.; de Cosa, A.; Galloni, C.; Hreus, T.; Kilminster, B.; Lange, C.; Maier, R.; Ngadiuba, J.; Pinna, D.; Robmann, P.; Taroni, S.; Yang, Y.; Bertl, W.; Deiters, K.; Erdmann, W.; Horisberger, R.; Kaestli, H.-C.; Kotlinski, D.; Langenegger, U.; Meier, B.; Rohe, T.; Streuli, S.; Chen, P.-H.; Dietz, C.; Grundler, U.; Hou, W.-S.; Lu, R.-S.; Moya, M.; Cussans, D.; Flacher, H.; Goldstein, J.; Grimes, M.; Jacob, J.; Seif El Nasr-Storey, S.; Cole, J.; Hoad, C.; Hobson, P.; Morton, A.; Reid, I. D.; Auzinger, G.; Bainbridge, R.; Dauncey, P.; Fulcher, J.; Hall, G.; James, T.; Magnan, A.-M.; Pesaresi, M.; Raymond, D. M.; Uchida, K.; Braga, D.; Coughlan, J. A.; Harder, K.; Jones, L.; Ilic, J.; Murray, P.; Prydderch, M.; Tomalin, I. R.; Garabedian, A.; Heintz, U.; Narain, M.; Nelson, J.; Sagir, S.; Speer, T.; Swanson, J.; Tersegno, D.; Watson-Daniels, J.; Chertok, M.; Conway, J.; Conway, R.; Flores, C.; Lander, R.; Pellett, D.; Ricci-Tam, F.; Squires, M.; Thomson, J.; Yohay, R.; Burt, K.; Ellison, J.; Hanson, G.; Olmedo, M.; Si, W.; Yates, B. R.; Gerosa, R.; Sharma, V.; Vartak, A.; Yagil, A.; Zevi Della Porta, G.; Dutta, V.; Gouskos, L.; Incandela, J.; Kyre, S.; Mullin, S.; Qu, H.; White, D.; Dominguez, A.; Bartek, R.; Cumalat, J. P.; Ford, W. T.; Jensen, F.; Johnson, A.; Krohn, M.; Leontsinis, S.; Mulholland, T.; Stenson, K.; Wagner, S. R.; Apresyan, A.; Bolla, G.; Burkett, K.; Butler, J. N.; Cheung, H. W. K.; Chramowicz, J.; Christian, D.; Cooper, W. E.; Deptuch, G.; Derylo, G.; Gingu, C.; Grünendahl, S.; Hasegawa, S.; Hoff, J.; Howell, J.; Hrycyk, M.; Jindariani, S.; Johnson, M.; Kahlid, F.; Lei, C. M.; Lipton, R.; Lopes De Sá, R.; Liu, T.; Los, S.; Matulik, M.; Merkel, P.; Nahn, S.; Prosser, A.; Rivera, R.; Schneider, B.; Sellberg, G.; Shenai, A.; Spiegel, L.; Tran, N.; Uplegger, L.; Voirin, E.; Berry, D. R.; Chen, X.; Ennesser, L.; Evdokimov, A.; Evdokimov, O.; Gerber, C. E.; Hofman, D. J.; Makauda, S.; Mills, C.; Sandoval Gonzalez, I. D.; Alimena, J.; Antonelli, L. J.; Francis, B.; Hart, A.; Hill, C. S.; Parashar, N.; Stupak, J.; Bortoletto, D.; Bubna, M.; Hinton, N.; Jones, M.; Miller, D. H.; Shi, X.; Tan, P.; Baringer, P.; Bean, A.; Khalil, S.; Kropivnitskaya, A.; Majumder, D.; Wilson, G.; Ivanov, A.; Mendis, R.; Mitchell, T.; Skhirtladze, N.; Taylor, R.; Anderson, I.; Fehling, D.; Gritsan, A.; Maksimovic, P.; Martin, C.; Nash, K.; Osherson, M.; Swartz, M.; Xiao, M.; Acosta, J. G.; Cremaldi, L. M.; Oliveros, S.; Perera, L.; Summers, D.; Bloom, K.; Claes, D. R.; Fangmeier, C.; Gonzalez Suarez, R.; Monroy, J.; Siado, J.; Hahn, K.; Sevova, S.; Sung, K.; Trovato, M.; Bartz, E.; Gershtein, Y.; Halkiadakis, E.; Kyriacou, S.; Lath, A.; Nash, K.; Osherson, M.; Schnetzer, S.; Stone, R.; Walker, M.; Malik, S.; Norberg, S.; Ramirez Vargas, J. E.; Alyari, M.; Dolen, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Kharchilava, A.; Nguyen, D.; Parker, A.; Rappoccio, S.; Roozbahani, B.; Alexander, J.; Chaves, J.; Chu, J.; Dittmer, S.; McDermott, K.; Mirman, N.; Rinkevicius, A.; Ryd, A.; Salvati, E.; Skinnari, L.; Soffi, L.; Tao, Z.; Thom, J.; Tucker, J.; Zientek, M.; Akgün, B.; Ecklund, K. M.; Kilpatrick, M.; Nussbaum, T.; Zabel, J.; Betchart, B.; Covarelli, R.; Demina, R.; Hindrichs, O.; Petrillo, G.; Eusebi, R.; Patel, R.; Perloff, A.; Ulmer, K. A.; Delannoy, A. G.; D'Angelo, P.; Johns, W.

    2018-03-01

    A new CMS Tracker is under development for operation at the High Luminosity LHC from 2026 onwards. It includes an outer tracker based on dedicated modules that will reconstruct short track segments, called stubs, using spatially coincident clusters in two closely spaced silicon sensor layers. These modules allow the rejection of low transverse momentum track hits and reduce the data volume before transmission to the first level trigger. The inclusion of tracking information in the trigger decision is essential to limit the first level trigger accept rate. A customized front-end readout chip, the CMS Binary Chip (CBC), containing stub finding logic has been designed for this purpose. A prototype module, equipped with the CBC chip, has been constructed and operated for the first time in a 4 GeemVem/emc positron beam at DESY. The behaviour of the stub finding was studied for different angles of beam incidence on a module, which allows an estimate of the sensitivity to transverse momentum within the future CMS detector. A sharp transverse momentum threshold around 2 emVem/emc was demonstrated, which meets the requirement to reject a large fraction of low momentum tracks present in the LHC environment on-detector. This is the first realistic demonstration of a silicon tracking module that is able to select data, based on the particle's transverse momentum, for use in a first level trigger at the LHC . The results from this test are described here.

  7. 45 CFR 150.203 - Circumstances requiring CMS enforcement.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Circumstances requiring CMS enforcement. 150.203... CARE ACCESS CMS ENFORCEMENT IN GROUP AND INDIVIDUAL INSURANCE MARKETS CMS Enforcement Processes for... requiring CMS enforcement. CMS enforces HIPAA requirements to the extent warranted (as determined by CMS) in...

  8. First cosmic rays seen in the CMS Tracker Endcap

    CERN Multimedia

    Lutz Feld, RWTH Aachen

    2006-01-01

    On March 14, 2006, first cosmic muon tracks have been measured in the Tracker EndCap TEC+ of the CMS silicon strip tracker. The end caps have silicon strip modules mounted onto wedge-shaped carbon fiber support plates called petals. Up to 28 modules are arranged in radial rings on both sides of these plates. One eighth of an end cap (called sector) is populated with 18 petals. The TEC+ endcap is currently being integrated at RWTH Aachen. 400 silicon modules with a total of 241664 channels, corresponding to one eighth of the endcap, are read-out simultaneously by final power supply and DAQ components. On the left is the TEC+ in Aachen, whilst on the right is a computer image of a cosmic ray traversing the many layers of silicon sensors. To understand the response to real particles, basic functionality testing was followed by a cosmic muon run. A total of 400 silicon strip modules are read out with a channel inefficiency of below 1% and a common mode noise of only 25% of the intrinsic noise.

  9. Performance of the HLT muon reconstruction used in CMS

    CERN Document Server

    Ferreres Sole, Silvia

    2017-01-01

    The Large Hadron Collider (LHC) generates millions of collision per second. These collisions take place inside the detector, which should read out the data and store it for further analysis. However, there is no possible way of storing all the data generated at the LHC and, if it was, not all the events are interesting for further analysis since the majority of them are low-momenta events. Therefore, detectors need a trigger system to select which events are interested for further analysis and store them. In order to achieve that, the CMS trigger system is a two-level system composed by the Level1 and the High Level Trigger (HLT) that reduces the event rate from the collision rate at the LHC (30GHz) to what is stored and analyzed offline (around 1KHz). When a collision takes place, the Level1 trigger performs a fast readout of the detector. From the information of the detector, basic quantities are created and a pure hardware decision is taken on whether the event should be accepted or not. The Level1 reduces...

  10. CMS Brochure (german version)

    CERN Multimedia

    Marcastel, F

    2007-01-01

    CMS is the heaviest detector at the LHC, the most powerful particle accelerator in the world, which will start up in 2008. A multi-purpose detector, CMS is composed of several systems built around a powerful superconducting magnet.

  11. CMS brochure (English version)

    CERN Document Server

    Marcastel, Fabienne

    2014-01-01

    CMS is the heaviest detector at the LHC, the most powerful particle accelerator in the world, which has started up in 2008. A multi-purpose detector, CMS is composed of several systems built around a powerful superconducting magnet.

  12. CMS brochure (Spanish version)

    CERN Multimedia

    Lefevre, C

    2008-01-01

    CMS is the heaviest detector at the LHC, the most powerful particle accelerator in the world, which will start up in 2008. A multi-purpose detector, CMS is composed of several systems built around a powerful superconducting magnet.

  13. Silicon strip detector qualification for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kaussen, Gordon

    2008-10-06

    To provide the best spatial resolution for the particle trajectory reconstruction and a very fast readout, the inner tracking system of CMS is build up of silicon detectors with a pixel tracker in the center surrounded by a strip tracker. The silicon strip tracker consists of so-called modules representing the smallest detection unit of the tracking device. These modules are mounted on higher-level structures called shells in the tracker inner barrel (TIB), rods in the tracker outer barrel (TOB), disks in the tracker inner disks (TID) and petals in the tracker end caps (TEC). The performance of the participating two shells of the TIB, four rods of the TOB and two petals of the TEC (representing about 1% of the final strip tracker) could be studied in different magnetic fields over a period of approximately two month using cosmic muon signals. The last test before inserting the tracker in the CMS experiment was the Tracker Slice Test performed in spring/summer 2007 at the Tracker Integration Facility (TIF) at CERN after installing all subdetectors in the tracker support tube. Approximately 25% of the strip tracker +z side was powered and read out using a cosmic ray trigger built up of scintillation counters. In total, about 5 million muon events were recorded under various operating conditions. These events together with results from commissioning runs were used to study the detector response like cluster charges, signal-to-noise ratios and single strip noise behaviour as well as to identify faulty channels which turned out to be in the order of a few per mille. The performance of the silicon strip tracker during these different construction stages is discussed in this thesis with a special emphasis on the tracker end caps. (orig.)

  14. Silicon strip detector qualification for the CMS experiment

    International Nuclear Information System (INIS)

    Kaussen, Gordon

    2008-01-01

    To provide the best spatial resolution for the particle trajectory reconstruction and a very fast readout, the inner tracking system of CMS is build up of silicon detectors with a pixel tracker in the center surrounded by a strip tracker. The silicon strip tracker consists of so-called modules representing the smallest detection unit of the tracking device. These modules are mounted on higher-level structures called shells in the tracker inner barrel (TIB), rods in the tracker outer barrel (TOB), disks in the tracker inner disks (TID) and petals in the tracker end caps (TEC). The performance of the participating two shells of the TIB, four rods of the TOB and two petals of the TEC (representing about 1% of the final strip tracker) could be studied in different magnetic fields over a period of approximately two month using cosmic muon signals. The last test before inserting the tracker in the CMS experiment was the Tracker Slice Test performed in spring/summer 2007 at the Tracker Integration Facility (TIF) at CERN after installing all subdetectors in the tracker support tube. Approximately 25% of the strip tracker +z side was powered and read out using a cosmic ray trigger built up of scintillation counters. In total, about 5 million muon events were recorded under various operating conditions. These events together with results from commissioning runs were used to study the detector response like cluster charges, signal-to-noise ratios and single strip noise behaviour as well as to identify faulty channels which turned out to be in the order of a few per mille. The performance of the silicon strip tracker during these different construction stages is discussed in this thesis with a special emphasis on the tracker end caps. (orig.)

  15. CMS brochure (English version)

    CERN Document Server

    2017-01-01

    CMS is the heaviest detector at the LHC, the most powerful particle accelerator in the world, which has started up in 2008. A multi-purpose detector, CMS is composed of several systems built around a powerful superconducting magnet.CMS est la plus lourde des expériences du LHC, l'accélérateur de particules le plus puissant au monde qui a été mis en service en 2008. Les détecteurs de cette expérience polyvalente sont placés autour d'un puissant aimant supraconducteur.

  16. CMS brochure (French version)

    CERN Document Server

    2017-01-01

    CMS is the heaviest detector at the LHC, the most powerful particle accelerator in the world, which has started up in 2008. A multi-purpose detector, CMS is composed of several systems built around a powerful superconducting magnet.CMS est la plus lourde des expériences du LHC, l'accélérateur de particules le plus puissant au monde qui a été mis en service en 2008. Les détecteurs de cette expérience polyvalente sont placés autour d'un puissant aimant supraconducteur.

  17. Irradiation study of different silicon materials for the CMS tracker upgrade

    CERN Document Server

    Erfle, Joachim; Hansen, Wolfgang; Garutti, Erika

    Around 2022, an upgrade of the LHC collider complex is planned to significantly increase the luminosity (the High Luminosity LHC, HL-LHC). This means that the experiments have to cope with a higher number of collisions per bunch crossing and survive in a radiation environment much harsher than that at the present LHC. Especially the tracking detectors have to be improved for the HL-LHC. The increased number of tracks requires an increase of the number of readout channels while the higher radiation makes new sensor materials necessary. Within CMS, a measurement campaign was initiated to study the performance of different silicon materials in a corresponding radiation environment. To simulate the expected radiation the samples were irradiated with neutrons and with protons with two different energies. Radiation damage can be divided in two categories. First, ionizing energy loss in the surface isolation layers of the sensor leads to a change of the concentration of charged states in the sensor surface and there...

  18. CMS overview

    CERN Document Server

    AUTHOR|(CDS)2071615

    2016-01-01

    Most recent CMS data related to the high-density QCD are presented for pp and PbPb collisions at 2.76 TeV and pPb collisions at 5.02 TeV. The PbPb collision is essential to understand collective behavior and the final-state effects for the detailed characteristics of hot, dense partonic matter, whereas the pPb collision provides the critical information on the initial-state effects including the modification of the parton distribution function in cold nuclei. This paper highlights some of recent heavy-ion related results from CMS.

  19. A new visitor centre for CMS

    CERN Document Server

    2001-01-01

    At the inauguration of the new CMS visitor centre. The CMS experiment inaugurated a new visitor centre at its Cessy site on 14 June. This will allow the thousands of people who come to CERN each year to follow the construction of one the Laboratory's flagship experiments first-hand. CERN receives over 20,000 visitors each year. Until recently, many of them were taken on a guided tour of one of the LEP experiments. With the closure of LEP, however, trips underground are no longer possible, and the Visits' Service has put in place a number of other itineraries (Bulletin 46/2000). Since the CMS detector will be almost entirely constructed in a surface hall, it is now taking a big share of the limelight. The CMS visitor centre has been built on a platform overlooking CMS construction. It contains a set of clear descriptive posters describing the experiment, along with a video projection showing animations and movies about CMS construction. In the coming weeks, a display of CMS detector elements will be added, as...

  20. Study of the spatial resolution for binary readout detectors

    Energy Technology Data Exchange (ETDEWEB)

    Yonamine, R., E-mail: ryo.yonamine@ulb.ac.be; Maerschalk, T.; Lentdecker, G. De

    2016-07-11

    Often the binary readout is proposed for high granularity detectors to reduce the generated data volume to be readout at the price of a somewhat reduced spatial resolution compared to an analogue readout. We have been studying single hit resolutions obtained with a binary readout using simulations as well as analytical approaches. In this note we show that the detector geometry could be optimized to offer an equivalent spatial resolution than with an analogue readout.

  1. Performance study of large area encoding readout MRPC

    Science.gov (United States)

    Chen, X. L.; Wang, Y.; Chen, G.; Han, D.; Wang, X.; Zeng, M.; Zeng, Z.; Zhao, Z.; Guo, B.

    2018-02-01

    Muon tomography system built by the 2-D readout high spatial resolution Multi-gap Resistive Plate Chamber (MRPC) detector is a project of Tsinghua University. An encoding readout method based on the fine-fine configuration has been used to minimize the number of the readout electronic channels resulting in reducing the complexity and the cost of the system. In this paper, we provide a systematic comparison of the MRPC detector performance with and without fine-fine encoding readout. Our results suggest that the application of the fine-fine encoding readout leads us to achieve a detecting system with slightly worse spatial resolution but dramatically reduce the number of electronic channels.

  2. Auger Physicists visit CMS

    CERN Multimedia

    Hoch, Michael

    2012-01-01

    Visit at CERN P5 CMS in the experimental cavern Alan Watson, Auger Spokesperson Emeritus, University of Leeds; Jim Cronin, Nobel Laureate, Auger Spokesperson Emeritus, University of Chicago; Jim Virdee, CMS Former Spokesperson, Imperial College; Jim Matthews, Auger Co-Spokesperson, Louisiana State University

  3. Photos from the CMS Photo Book

    CERN Multimedia

    Boreham, S

    2008-01-01

    Photos from the CMS Photo Book. Activities at Point 5 in Cessy, France, between 1998 - 2008. Images of assembly and Installation of the CMS detector: - Civil Engineering - Assembly in the Surface Building - Lowering of the Heavy Elements - Installing and connecting the CMS detector in the underground experiment These images illustrate the assembly, installation and commissioning of the CMS detector. They cover the activities at Point 5 in Cessy, France, between 1998 and 2008. CMS is one of the most complex scientific instruments ever built. It has taken about 20 years to go from conceptual design to the completion of construction of the CMS detector for the LHC start-up in September 2008. Accomplishing this has required the talents, efforts and resources of over 2500 scientists and engineers from about 180 institutions in 38 countries. caverns Compiled by: S. Cittolin, F. Marcastel and T.S. Virdee

  4. CMS Higgs boson results

    CERN Document Server

    Bluj, Michal Jacek

    2018-01-01

    In this report we review recent Higgs boson results obtained with pp collisions at $\\sqrt{s}=\\,$13 TeV recorded by the CMS detector in 2016 for an integrated luminosity of 35.9fb$^{\\text{-1}}$. The 2016 data allowed the observation of the $H \\to \\tau\\tau$ and $H \\to WW$ decays with high significance. We also present a combined measurement based on a full set of CMS analyses performed with 2016 data. These results are compatible with the standard model predictions with precision of several measurements exceeding results from combination of ATLAS and CMS data collected in 2011 and 2012.

  5. Russian institute receives CMS Gold Award

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The Snezhinsk All-Russian Institute of Scientific Research for Technical Physics (VNIITF) of the Russian Federal Nuclear Centre (RFNC) is one of twelve CMS suppliers to receive awards for outstanding performance this year. The CMS Collaboration took the opportunity of the visit to CERN of the Director of VNIITF and his deputy to present the CMS Gold Award, which the institute has received for its exceptional performance in the assembly of steel plates for the CMS forward hadronic calorimeter. This calorimeter consists of two sets of 18 wedge-shaped modules arranged concentrically around the beam-pipe at each end of the CMS detector. Each module consists of steel absorber plates with quartz fibres inserted into them. The institute developed a special welding technique to assemble the absorber plates, enabling a high-quality detector to be produced at relatively low cost.RFNC-VNIITF Director Professor Georgy Rykovanov (right), is seen here receiving the Gold Award from Felicitas Pauss, Vice-Chairman of the CMS ...

  6. Conceptual investigations of a trigger extension for muons from pp collisions in the CMS experiment

    International Nuclear Information System (INIS)

    Erdogan, Yusuf

    2015-01-01

    As of 2023, the Large Hadron Collider can provide its experiments with five to ten times more luminosity than the current design value of 10 34 cm -2 s -1 . This upgrade will allow for the measurement of physics processes with very small cross sections. However, at these high luminosities, due to the pileup interactions, the detector occupancy will be very high. This will cause, on the one hand, a systematic increase of the trigger rates for single muons. On the other hand, amplified by the limited momentum resolution of the muon system, mismeasurements of the transverse momenta of muons will be dominant in the high momentum regime. In this region, the trigger rate distribution will saturate and the rate limitation with a transverse momentum threshold will be difficult. Furthermore, the quality of the single muon trigger at Level 1 will be decreased due to coincident particle transitions causing ambiguities in the innermost muon chambers. In 2007, a concept called Muon Track fast Tag (MTT) was introduced to address these trigger challenges. The studies, performed in this thesis, are divided into three parts. Concerning the MTT proposal, the main part deals with conceptual investigations on the possible trigger extension for muons from proton proton collisions in the CMS experiment. Thereby, the focus lies on the fundamental question of the muon detection capability of a scintillator system with SiPM readout. Such a system is the Hadron Outer calorimeter of CMS which is used for studies to answer this question. In the second part, the integration of the MTT system in the geometry description of the CMS detector is outlined. Thereby, it is written as a technical recipe which allows the understanding of the implementation of a new detector system in the CMS detector description. The last part of this thesis focuses on the Geant 4 simulations of the first MTT prototype. In this part, together with the simulation setup, selected results are introduced.

  7. CMS (Compact Muon Solenoid)

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    The milestone workshops on LHC experiments in Aachen in 1990 and at Evian in 1992 provided the first sketches of how LHC detectors might look. The concept of a compact general-purpose LHC experiment based on a solenoid to provide the magnetic field was first discussed at Aachen, and the formal Expression of Interest was aired at Evian. It was here that the Compact Muon Solenoid (CMS) name first became public. Optimizing first the muon detection system is a natural starting point for a high luminosity (interaction rate) proton-proton collider experiment. The compact CMS design called for a strong magnetic field, of some 4 Tesla, using a superconducting solenoid, originally about 14 metres long and 6 metres bore. (By LHC standards, this warrants the adjective 'compact'.) The main design goals of CMS are: 1 - a very good muon system providing many possibilities for momentum measurement (physicists call this a 'highly redundant' system); 2 - the best possible electromagnetic calorimeter consistent with the above; 3 - high quality central tracking to achieve both the above; and 4 - an affordable detector. Overall, CMS aims to detect cleanly the diverse signatures of new physics by identifying and precisely measuring muons, electrons and photons over a large energy range at very high collision rates, while also exploiting the lower luminosity initial running. As well as proton-proton collisions, CMS will also be able to look at the muons emerging from LHC heavy ion beam collisions. The Evian CMS conceptual design foresaw the full calorimetry inside the solenoid, with emphasis on precision electromagnetic calorimetry for picking up photons. (A light Higgs particle will probably be seen via its decay into photon pairs.) The muon system now foresaw four stations. Inner tracking would use silicon microstrips and microstrip gas chambers, with over 10 7 channels offering high track finding efficiency. In the central CMS barrel, the tracking elements are

  8. 42 CFR 489.53 - Termination by CMS.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Termination by CMS. 489.53 Section 489.53 Public... Reinstatement After Termination § 489.53 Termination by CMS. (a) Basis for termination of agreement with any provider. CMS may terminate the agreement with any provider if CMS finds that any of the following failings...

  9. Jim Virdee, the new spokesperson of CMS

    CERN Multimedia

    2006-01-01

    Jim Virdee and Michel Della Negra. On 21 June Tejinder 'Jim'Virdee was elected by the CMS collaboration as its new spokesperson, his 3-year term of office beginning in January 2007. He will take over from Michel Della Negra, who has been CMS spokesperson since its formalization in 1992. Three distinguished physicists stood as candidates for this election: Dan Green from Fermilab, programme manager of the US-CMS collaboration and coordinator of the CMS Hadron Calorimeter project; Jim Virdee from Imperial College London and CERN, deputy spokesperson of CMS since 1993; Gigi Rolandi from the University of Trieste and CERN, ex-Aleph spokesperson and currently involved in the preparations of the physics analyses to be done with CMS. On the early evening of 21 June, 141 of the 142 members of the CMS collaboration board, some represented by proxies, took part in a secret ballot. After two rounds of voting Jim Virdee was elected as spokesperson with a clear majority. Jim thanked the CMS collaboration 'for putting conf...

  10. BATS, the readout control of UA1

    Energy Technology Data Exchange (ETDEWEB)

    Botlo, M.; Dorenbosch, J.; Jimack, M.; Szoncso, F.; Taurok, A.; Walzel, G. (European Organization for Nuclear Research, Geneva (Switzerland))

    1991-04-15

    A steadily rising luminosity and different readout architectures for the various detector systems of UA1 required a new data flow control to minimize the dead time. BATS, a finite state machine conceived around two microprocessors in a single VME crate, improved flexibility and reliability. Compatibility with BATS streamlined all readout branches. BATS also proved to be a valuable asset in spotting readout problems and previously undetected data flow bottlenecks. (orig.).

  11. 42 CFR 401.108 - CMS rulings.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false CMS rulings. 401.108 Section 401.108 Public Health... GENERAL ADMINISTRATIVE REQUIREMENTS Confidentiality and Disclosure § 401.108 CMS rulings. (a) After... regulations, but which has been adopted by CMS as having precedent, may be published in the Federal Register...

  12. CMS tracker visualization tools

    Energy Technology Data Exchange (ETDEWEB)

    Mennea, M.S. [Dipartimento Interateneo di Fisica ' Michelangelo Merlin' e INFN sezione di Bari, Via Amendola 173 - 70126 Bari (Italy); Osborne, I. [Northeastern University, 360 Huntington Avenue, Boston, MA 02115 (United States); Regano, A. [Dipartimento Interateneo di Fisica ' Michelangelo Merlin' e INFN sezione di Bari, Via Amendola 173 - 70126 Bari (Italy); Zito, G. [Dipartimento Interateneo di Fisica ' Michelangelo Merlin' e INFN sezione di Bari, Via Amendola 173 - 70126 Bari (Italy)]. E-mail: giuseppe.zito@ba.infn.it

    2005-08-21

    This document will review the design considerations, implementations and performance of the CMS Tracker Visualization tools. In view of the great complexity of this sub-detector (more than 50 millions channels organized in 16540 modules each one of these being a complete detector), the standard CMS visualization tools (IGUANA and IGUANACMS) that provide basic 3D capabilities and integration within CMS framework, respectively, have been complemented with additional 2D graphics objects. Based on the experience acquired using this software to debug and understand both hardware and software during the construction phase, we propose possible future improvements to cope with online monitoring and event analysis during data taking.

  13. CMS tracker visualization tools

    CERN Document Server

    Zito, G; Osborne, I; Regano, A

    2005-01-01

    This document will review the design considerations, implementations and performance of the CMS Tracker Visualization tools. In view of the great complexity of this sub-detector (more than 50 millions channels organized in 16540 modules each one of these being a complete detector), the standard CMS visualization tools (IGUANA and IGUANACMS) that provide basic 3D capabilities and integration within CMS framework, respectively, have been complemented with additional 2D graphics objects. Based on the experience acquired using this software to debug and understand both hardware and software during the construction phase, we propose possible future improvements to cope with online monitoring and event analysis during data taking.

  14. CMS tracker visualization tools

    International Nuclear Information System (INIS)

    Mennea, M.S.; Osborne, I.; Regano, A.; Zito, G.

    2005-01-01

    This document will review the design considerations, implementations and performance of the CMS Tracker Visualization tools. In view of the great complexity of this sub-detector (more than 50 millions channels organized in 16540 modules each one of these being a complete detector), the standard CMS visualization tools (IGUANA and IGUANACMS) that provide basic 3D capabilities and integration within CMS framework, respectively, have been complemented with additional 2D graphics objects. Based on the experience acquired using this software to debug and understand both hardware and software during the construction phase, we propose possible future improvements to cope with online monitoring and event analysis during data taking

  15. Data Scouting in CMS

    CERN Document Server

    Anderson, Dustin James

    2016-01-01

    In 2011, the CMS collaboration introduced Data Scouting as a way to produce physics results with events that cannot be stored on disk, due to resource limits in the data acquisition and offline infrastructure. The viability of this technique was demonstrated in 2012, when 18 fb$^{-1}$ of collision data at $\\sqrt{s}$ = 8 TeV were collected. The technique is now a standard ingredient of CMS and ATLAS data-taking strategy. In this talk, we present the status of data scouting in CMS and the improvements introduced in 2015 and 2016, which promoted data scouting to a full-fledged, flexible discovery tool for the LHC Run II.

  16. Data acquisition and online control system for new gas-electron multiplier detectors in the endcap muon system of the CMS experiment

    CERN Document Server

    Ruiz Alvarez, Jose David

    2016-01-01

    A new data acquisition and on-line control system is being developed for gas-electron multiplier (GEM) detectors which will be installed in the forward region (1.6 \\( < \\eta < \\) 2.2) of the CMS muon spectrometer during the 2nd long shutdown of the LHC, planned for the period 2018-2019. A prototype system employs the TOTEM VFAT2 ASIC that will eventually be replaced with the VFAT3 ASIC, under development. The front-end ASIC communicates over printed circuit lines with an intermediate on-detector board called the opto-hybrid. Data, trigger, and control information is transmitted via optical fiber between the opto-hybrid and an off-detector readout system using micro-TCA technology. On-line software, implemented in the CMS XDAQ framework, includes applications for latency and HV scans, and system management. We report on the operational status of the prototype system that has been tested using cosmic ray muons and extracted high-energy particle beams. This work is preparatory for the operation of a prot...

  17. A micro-TCA based data acquisition system for the Triple-GEM detectors for the upgrade of the CMS forward muon spectrometer

    Science.gov (United States)

    Lenzi, T.

    2017-01-01

    The Gas Electron Multiplier (GEM) upgrade project aims at improving the performance of the muon spectrometer of the Compact Muon Solenoid (CMS) experiment which will suffer from the increase in luminosity of the Large Hadron Collider (LHC). The GEM collaboration proposes to instrument the first muon station with Triple-GEM detectors, a technology which has proven to be resistant to high fluxes of particles. The architecture of the readout system is based on the use of the microTCA standard hosting FPGA-based Advanced Mezzanine Card (AMC) and of the Versatile Link with the GBT chipset to link the on-detector electronics to the micro-TCA boards. For the front-end electronics a new ASIC, called VFAT3, is being developed. On the detector, a Xilinx Virtex-6 FPGA mezzanine board, called the OptoHybrid, has to collect the data from 24 VFAT3s and to transmit the data optically to the off-detector micro-TCA electronics, as well as to transmit the trigger data at 40 MHz to the CMS Cathode Strip Chamber (CSC) trigger. The microTCA electronics provides the interfaces from the detector (and front-end electronics) to the CMS DAQ, TTC (Timing, Trigger and Control) and Trigger systems. In this paper, we will describe the DAQ system of the Triple-GEM project and provide results from the latest test beam campaigns done at CERN.

  18. Silicon Sensor and Detector Developments for the CMS Tracker Upgrade

    CERN Document Server

    D'Alessandro, Raffaello

    2011-01-01

    CMS started a campaign to identify the future silicon sensor technology baseline for a new Tracker for the high-luminosity phase of LHC, coupled to a new effective way of providing tracking information to the experiment trigger. To this end a large variety of 6'' wafers was acquired in different thicknesses and technologies at HPK and new detector module designs were investigated. Detector thicknesses ranging from 50$\\mu$m to 300$\\mu$m are under investigation on float zone, magnetic Czochralski and epitaxial material both in n-in-p and p-in-n versions. P-stop and p-spray are explored as isolation technology for the n-in-p type sensors as well as the feasibility of double metal routing on 6'' wafers. Each wafer contains different structures to answer different questions, e.g. influence of geometry, Lorentz angle, radiation tolerance, annealing behaviour, validation of read-out schemes. Dedicated process test-structures, as well as diodes, mini-sensors, long and very short strip sensors and real pixel sensors ...

  19. CMS data and workflow management system

    CERN Document Server

    Fanfani, A; Bacchi, W; Codispoti, G; De Filippis, N; Pompili, A; My, S; Abbrescia, M; Maggi, G; Donvito, G; Silvestris, L; Calzolari, F; Sarkar, S; Spiga, D; Cinquili, M; Lacaprara, S; Biasotto, M; Farina, F; Merlo, M; Belforte, S; Kavka, C; Sala, L; Harvey, J; Hufnagel, D; Fanzago, F; Corvo, M; Magini, N; Rehn, J; Toteva, Z; Feichtinger, D; Tuura, L; Eulisse, G; Bockelman, B; Lundstedt, C; Egeland, R; Evans, D; Mason, D; Gutsche, O; Sexton-Kennedy, L; Dagenhart, D W; Afaq, A; Guo, Y; Kosyakov, S; Lueking, L; Sekhri, V; Fisk, I; McBride, P; Bauerdick, L; Bakken, J; Rossman, P; Wicklund, E; Wu, Y; Jones, C; Kuznetsov, V; Riley, D; Dolgert, A; van Lingen, F; Narsky, I; Paus, C; Klute, M; Gomez-Ceballos, G; Piedra-Gomez, J; Miller, M; Mohapatra, A; Lazaridis, C; Bradley, D; Elmer, P; Wildish, T; Wuerthwein, F; Letts, J; Bourilkov, D; Kim, B; Smith, P; Hernandez, J M; Caballero, J; Delgado, A; Flix, J; Cabrillo-Bartolome, I; Kasemann, M; Flossdorf, A; Stadie, H; Kreuzer, P; Khomitch, A; Hof, C; Zeidler, C; Kalini, S; Trunov, A; Saout, C; Felzmann, U; Metson, S; Newbold, D; Geddes, N; Brew, C; Jackson, J; Wakefield, S; De Weirdt, S; Adler, V; Maes, J; Van Mulders, P; Villella, I; Hammad, G; Pukhaeva, N; Kurca, T; Semneniouk, I; Guan, W; Lajas, J A; Teodoro, D; Gregores, E; Baquero, M; Shehzad, A; Kadastik, M; Kodolova, O; Chao, Y; Ming Kuo, C; Filippidis, C; Walzel, G; Han, D; Kalinowski, A; Giro de Almeida, N M; Panyam, N

    2008-01-01

    CMS expects to manage many tens of peta bytes of data to be distributed over several computing centers around the world. The CMS distributed computing and analysis model is designed to serve, process and archive the large number of events that will be generated when the CMS detector starts taking data. The underlying concepts and the overall architecture of the CMS data and workflow management system will be presented. In addition the experience in using the system for MC production, initial detector commissioning activities and data analysis will be summarized.

  20. Debugging Data Transfers in CMS

    CERN Document Server

    Bagliesi, G; Bloom, K; Bockelman, B; Bonacorsi, D; Fisk, I; Flix, J; Hernandez, J; D'Hondt, J; Kadastik, M; Klem, J; Kodolova, O; Kuo, C M; Letts, J; Maes, J; Magini, N; Metson, S; Piedra, J; Pukhaeva, N; Tuura, L; Sonajalg, S; Wu, Y; Van Mulders, P; Villella, I; Wurthwein, F

    2010-01-01

    The CMS experiment at CERN is preparing for LHC data taking in several computing preparation activities. In early 2007 a traffic load generator infrastructure for distributed data transfer tests called the LoadTest was designed and deployed to equip the WLCG sites that support CMS with a means for debugging, load-testing and commissioning data transfer routes among CMS computing centres. The LoadTest is based upon PhEDEx as a reliable, scalable data set replication system. The Debugging Data Transfers (DDT) task force was created to coordinate the debugging of the data transfer links. The task force aimed to commission most crucial transfer routes among CMS sites by designing and enforcing a clear procedure to debug problematic links. Such procedure aimed to move a link from a debugging phase in a separate and independent environment to a production environment when a set of agreed conditions are achieved for that link. The goal was to deliver one by one working transfer routes to the CMS data operations team...

  1. Evolution of the dual-readout calorimeter

    Indian Academy of Sciences (India)

    ... a calorimeter system of a relatively simple construction and moderate costs, however with excellent properties, built upon experience gained with the extensively beam-tested DREAM (Dual REAdout. Module) prototype. The main idea of multiple readout calorimetry is to indepen- dently measure for each hadronic shower ...

  2. Offline Reconstruction Algorithms for the CMS High Granularity Calorimeter for HL-LHC

    CERN Document Server

    Chen, Z; Meschi, Emilio; Scott, Edward John Titman; Seez, Christopher

    2017-01-01

    The upgraded High Luminosity LHC, after the third Long Shutdown (LS3), will provide an instantaneous luminosity of $7.5 \\times 10^{34}$ cm$^{-2}$ s$^{-1}$ (levelled), at theCollaboration price of extreme pileup of up to 200 interactions per crossing. Such extreme pileup poses significant challenges, in particular for forward calorimetry. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic and hadronic compartments. The electromagnetic and a large fraction of the hadronic portions will be based on hexagonal silicon sensors of 0.5 - 1 cm$^2$ cell size, with the remainder of the hadronic portion based on highly-segmented scintillators with SiPM readout. Offline clustering algorithms that make use of this extreme granularity require novel approaches to preserve the fine structure of showers and to be stable against pileup, wh...

  3. Development of radiation-hard optical links for the CMS tracker at CERN

    International Nuclear Information System (INIS)

    Vasey, F.; Arbet-Engels, V.; Cervelli, G.; Gill, K.; Grabit, R.; Mommaert, C.; Stefanini, G.

    1998-01-01

    A radiation-hard optical link is under development for readout and control of the tracking detector in the future CMS experiment at the CERN Large Hadron Collider. The authors present the optical system architecture based on edge-emitting InGaAsP laser-diode transmitters operating at a wavelength of 1.3 microm, single mode fiber ribbons, multi-way connectors and InGaAsP in photodiode receivers. They report on radiation hardness tests of lasers, photodiodes, fibers and connectors. Increases of laser threshold and pin leakage currents with hadron fluence have been observed together with decreases in laser slope-efficiency and photodiode responsivity. Short lengths of single-mode optical fiber and multi-way connectors have been found to be little affected by radiation damage. They analyze the analog and digital performance of prototype optical links transmitting data generated at a 40 MSample/s rate. Distortion, settling time, bandwidth, noise, dynamic range and bit-error-rate results are discussed

  4. LHCC COMPREHENSIVE REVIEW OF CMS (JULY 07)

    CERN Multimedia

    Extract from the Draft Report 1. EXECUTIVE SUMMARY The CMS Collaboration has made significant progress towards producing a detector ready for LHC operation in 2008. The past year saw all sub-detector groups success fully produce high-quality components and modules, and integrate them into the final objects to be installed into the CMS magnet. Installation and commissioning of final components in the CMS UXC55 cavern are well-under-way. In particular, the heavy lowering of detector elements into the CMS experiment cavern is a major success. The new CMS master schedule V36 incorporates the revised LHC machine schedule and includes an optimized detector sequencing. In spite of various delays, it remains possible that CMS will have an initial detector ready to exploit the initial LHC run in spring 2008. Installation of the Electromagnetic Calorimeter End-Cap (EE) and Pre-shower (ES) detectors is scheduled to be completed no sooner than July 2008 and CMS now plans to install the complete Pixel Detector for ...

  5. The CMS Magnetic Field Map Performance

    CERN Document Server

    Klyukhin, V.I.; Andreev, V.; Ball, A.; Cure, B.; Herve, A.; Gaddi, A.; Gerwig, H.; Karimaki, V.; Loveless, R.; Mulders, M.; Popescu, S.; Sarycheva, L.I.; Virdee, T.

    2010-04-05

    The Compact Muon Solenoid (CMS) is a general-purpose detector designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive featuresinclude a 4 T superconducting solenoid with 6 m diameter by 12.5 m long free bore, enclosed inside a 10000-ton return yoke made of construction steel. Accurate characterization of the magnetic field everywhere in the CMS detector is required. During two major tests of the CMS magnet the magnetic flux density was measured inside the coil in a cylinder of 3.448 m diameter and 7 m length with a specially designed field-mapping pneumatic machine as well as in 140 discrete regions of the CMS yoke with NMR probes, 3-D Hall sensors and flux-loops. A TOSCA 3-D model of the CMS magnet has been developed to describe the magnetic field everywhere outside the tracking volume measured with the field-mapping machine. A volume based representation of the magnetic field is used to provide the CMS simulation and reconstruction software with the magnetic field ...

  6. Guido Tonelli elected next CMS spokesperson

    CERN Multimedia

    2009-01-01

    Guido Tonelli has been elected as the next CMS spokesperson. He will take over from Jim Virdee on January 1, 2010, and will head the collaboration through the first crucial year of data-taking. Guido Tonelli, CMS spokesperson-elect, into the CMS cavern. "It will be very tough and there will be enormous pressure," explains Guido Tonelli, CMS spokesperson-elect. "It will be the first time that CMS will run for a whole year so it is important to go through the checklist to be able to take good quality data." Tonelli, who is currently CMS Deputy spokesperson, will take over from Jim Virdee on January 1, 2010 – only a few months into CMS’s first full year of data-taking. "The collisions will probably be different to our expectations. So it’s going to take the effort of the entire collaboration worldwide to be ready for this new phase." Born in Italy, Tonelli originally studied at the University of Pisa, where he is now a Professo...

  7. Distributed computing grid experiences in CMS

    CERN Document Server

    Andreeva, Julia; Barrass, T; Bonacorsi, D; Bunn, Julian; Capiluppi, P; Corvo, M; Darmenov, N; De Filippis, N; Donno, F; Donvito, G; Eulisse, G; Fanfani, A; Fanzago, F; Filine, A; Grandi, C; Hernández, J M; Innocente, V; Jan, A; Lacaprara, S; Legrand, I; Metson, S; Newbold, D; Newman, H; Pierro, A; Silvestris, L; Steenberg, C; Stockinger, H; Taylor, Lucas; Thomas, M; Tuura, L; Van Lingen, F; Wildish, Tony

    2005-01-01

    The CMS experiment is currently developing a computing system capable of serving, processing and archiving the large number of events that will be generated when the CMS detector starts taking data. During 2004 CMS undertook a large scale data challenge to demonstrate the ability of the CMS computing system to cope with a sustained data- taking rate equivalent to 25% of startup rate. Its goals were: to run CMS event reconstruction at CERN for a sustained period at 25 Hz input rate; to distribute the data to several regional centers; and enable data access at those centers for analysis. Grid middleware was utilized to help complete all aspects of the challenge. To continue to provide scalable access from anywhere in the world to the data, CMS is developing a layer of software that uses Grid tools to gain access to data and resources, and that aims to provide physicists with a user friendly interface for submitting their analysis jobs. This paper describes the data challenge experience with Grid infrastructure ...

  8. Faces of CMS: Photomosaic (September 2013, low-resolution)

    CERN Multimedia

    Antonelli, Jamie

    2013-01-01

    The "Faces of CMS" photomosaic project aims to show the human element of the CMS Experiment. Most of the images for public outreach show the experimental equipment of CMS or physics results and collision displays. With a collaboration of around 3,000 people scattered around the globe, it's difficult to present the members of CMS in any one image. We asked any interested CMS members to sign up for the project, and allow us to use their photographs. The resulting photo mosaic contains the faces of 1,271 CMS members.

  9. Silicon sensors for the upgrades of the CMS pixel detector

    International Nuclear Information System (INIS)

    Centis Vignali, Matteo

    2015-12-01

    The Compact Muon Solenoid (CMS) is a general purpose detector at the Large Hadron Collider (LHC). The LHC luminosity is constantly increased through upgrades of the accelerator and its injection chain. Two major upgrades will take place in the next years. The first upgrade involves the LHC injector chain and allows the collider to achieve a luminosity of about 2.10 34 cm -2 s -1 . A further upgrade of the LHC foreseen for 2025 will boost its luminosity to 5.10 34 cm -2 s -1 . As a consequence of the increased luminosity, the detectors need to be upgraded. In particular, the CMS pixel detector will undergo two upgrades in the next years. The first upgrade (phase I) consists in the substitution of the current pixel detector in winter 2016/2017. The upgraded pixel detector will implement new readout electronics that allow efficient data taking up to a luminosity of 2.10 34 cm -2 s -1 , twice as much as the LHC design luminosity. The modules that will constitute the upgraded detector are being produced at different institutes. Hamburg (University and DESY) is responsible for the production of 350 pixel modules. The second upgrade (phase II) of the pixel detector is foreseen for 2025. The innermost pixel layer of the upgraded detector will accumulate a radiation damage corresponding to an equivalent fluence of Φ eq =2.10 16 cm -2 and a dose of ∼10 MGy after an integrated luminosity of 3000 fb -1 . Several groups are investigating sensor designs and configurations able to withstand such high doses and fluences. This work is divided into two parts related to important aspects of the upgrades of the CMS pixel detector. For the phase I upgrade, a setup has been developed to provide an absolute energy calibration of the pixel modules that will constitute the detector. The calibration is obtained using monochromatic X-rays. The same setup is used to test the buffering capabilities of the modules' readout chip. The maximum rate experienced by the modules produced in

  10. New Management for CMS

    CERN Document Server

    CERN Bulletin

    2010-01-01

    As of January 2010, Guido Tonelli becomes the new CMS Spokesperson with a two-year term of office. A Professor of General Physics at the University of Pisa, Italy, and a CERN Staff Member since January 2010, Tonelli had already been appointed as Deputy Spokesperson under the previous management. He has taken over from Jim Virdee, who was CMS Spokesperson from January 2007 to December 2009. Guido Tonelli, new CMS spokesperson At the same time as Tonelli becomes Spokesperson, two new Deputies, Albert De Roeck and Joe Incandela, as well as a whole new set of Coordinators, are also starting their terms of office. ”With the first data-taking run we have shown that CMS is an excellent experiment. The next challenge will be to transform CMS into a discovery machine with a view to making it synonymous with scientific excellence. This will be very tough but, again, the winning element will be the focus and coherent effort of the whole collaboration. On my side I'll do my best but I will need...

  11. Distributed Analysis in CMS

    CERN Document Server

    Fanfani, Alessandra; Sanches, Jose Afonso; Andreeva, Julia; Bagliesi, Giusepppe; Bauerdick, Lothar; Belforte, Stefano; Bittencourt Sampaio, Patricia; Bloom, Ken; Blumenfeld, Barry; Bonacorsi, Daniele; Brew, Chris; Calloni, Marco; Cesini, Daniele; Cinquilli, Mattia; Codispoti, Giuseppe; D'Hondt, Jorgen; Dong, Liang; Dongiovanni, Danilo; Donvito, Giacinto; Dykstra, David; Edelmann, Erik; Egeland, Ricky; Elmer, Peter; Eulisse, Giulio; Evans, Dave; Fanzago, Federica; Farina, Fabio; Feichtinger, Derek; Fisk, Ian; Flix, Josep; Grandi, Claudio; Guo, Yuyi; Happonen, Kalle; Hernandez, Jose M; Huang, Chih-Hao; Kang, Kejing; Karavakis, Edward; Kasemann, Matthias; Kavka, Carlos; Khan, Akram; Kim, Bockjoo; Klem, Jukka; Koivumaki, Jesper; Kress, Thomas; Kreuzer, Peter; Kurca, Tibor; Kuznetsov, Valentin; Lacaprara, Stefano; Lassila-Perini, Kati; Letts, James; Linden, Tomas; Lueking, Lee; Maes, Joris; Magini, Nicolo; Maier, Gerhild; McBride, Patricia; Metson, Simon; Miccio, Vincenzo; Padhi, Sanjay; Pi, Haifeng; Riahi, Hassen; Riley, Daniel; Rossman, Paul; Saiz, Pablo; Sartirana, Andrea; Sciaba, Andrea; Sekhri, Vijay; Spiga, Daniele; Tuura, Lassi; Vaandering, Eric; Vanelderen, Lukas; Van Mulders, Petra; Vedaee, Aresh; Villella, Ilaria; Wicklund, Eric; Wildish, Tony; Wissing, Christoph; Wurthwein, Frank

    2009-01-01

    The CMS experiment expects to manage several Pbytes of data each year during the LHC programme, distributing them over many computing sites around the world and enabling data access at those centers for analysis. CMS has identified the distributed sites as the primary location for physics analysis to support a wide community with thousands potential users. This represents an unprecedented experimental challenge in terms of the scale of distributed computing resources and number of user. An overview of the computing architecture, the software tools and the distributed infrastructure is reported. Summaries of the experience in establishing efficient and scalable operations to get prepared for CMS distributed analysis are presented, followed by the user experience in their current analysis activities.

  12. The new silicon strip detectors for the CMS tracker upgrade

    International Nuclear Information System (INIS)

    Dragicevic, M.

    2010-01-01

    The first introductory part of the thesis describes the concept of the CMS experiment. The tasks of the various detector systems and their technical implementations in CMS are explained. To facilitate the understanding of the basic principles of silicon strip sensors, the subsequent chapter discusses the fundamentals in semiconductor technology, with particular emphasis on silicon. The necessary process steps to manufacture strip sensors in a so-called planar process are described in detail. Furthermore, the effects of irradiation on silicon strip sensors are discussed. To conclude the introductory part of the thesis, the design of the silicon strip sensors of the CMS Tracker are described in detail. The choice of the substrate material and the complex geometry of the sensors are reviewed and the quality assurance procedures for the production of the sensors are presented. Furthermore the design of the detector modules are described. The main part of this thesis starts with a discussion on the demands on the tracker caused by the increase in luminosity which is proposed as an upgrade to the LHC accelerator (sLHC). This chapter motivates the work I have conducted and clarifies why the solutions proposed by myself are important contributions to the upgrade of the CMS tracker. The following chapters present the concepts that are necessary to operate the silicon strip sensors at sLHC luminosities and additional improvements to the construction and quality assurance of the sensors and the detector modules. The most important concepts and works presented in chapters 7 to 9 are: Development of a software framework to enable the flexible and quick design of test structures and sensors. Selecting a suitable sensor material which is sufficiently radiation hard. Design, implementation and production of a standard set of test structures to enable the quality assurance of such sensors and any future developments. Electrical characterisation of the test structures and analysis

  13. Enabling opportunistic resources for CMS Computing Operations

    Energy Technology Data Exchange (ETDEWEB)

    Hufnagel, Dick [Fermilab

    2015-11-19

    With the increased pressure on computing brought by the higher energy and luminosity from the LHC in Run 2, CMS Computing Operations expects to require the ability to utilize “opportunistic” resources — resources not owned by, or a priori configured for CMS — to meet peak demands. In addition to our dedicated resources we look to add computing resources from non CMS grids, cloud resources, and national supercomputing centers. CMS uses the HTCondor/glideinWMS job submission infrastructure for all its batch processing, so such resources will need to be transparently integrated into its glideinWMS pool. Bosco and parrot wrappers are used to enable access and bring the CMS environment into these non CMS resources. Here we describe our strategy to supplement our native capabilities with opportunistic resources and our experience so far using them.

  14. Last crystals for the CMS chandelier

    CERN Multimedia

    2008-01-01

    In March, the last crystals for CMS’s electromagnetic calorimeter arrived from Russia and China. Like dedicated jewellers crafting an immense chandelier, the CMS ECAL collaborators are working extremely hard to install all the crystals before the start-up of the LHC. One of the last CMS end-cap crystals, complete with identification bar code. Lead tungstate crystals mounted onto one section of the CMS ECAL end caps. Nearly 10 years after the first production crystal arrived at CERN in September 1998, the very last shipment has arrived. These final crystals will be used to complete the end-caps of the electromagnetic calorimeter (ECAL) at CMS. All in all, there are more than 75,000 crystals in the ECAL. The huge quantity of CMS lead tungstate crystals used in the ECAL corresponds to the highest volume ever produced for a single experiment. The excellent quality of the crystals, both in ter...

  15. CMS ready for winding up

    CERN Multimedia

    2003-01-01

    End of October, the last lengths of conductor for the CMS superconducting solenoid have been produced. This is another large sub-project of the CMS Magnet being successfully finished, after completion of the Yoke last year (see Bulletin 43/2002).

  16. CMS Comic Book

    CERN Document Server

    Gill, Karl Aaron

    2006-01-01

    Titled "CMS Particle Hunter," this colorful comic book style brochure explains to young budding scientists and science enthusiasts in colorful animation how the CMS detector was made, its main parts, and what scientists hope to find using this complex tool. Book invites young students to get involved in particle physics themselves to join the adventure. Written by Dave Barney and Aline Guevera. Layout and drawings by Eric Paiharey and Frederic Vignaux. Available in English, French, German, Italian, Spanish and Portuguese. Year Produced: 2006. Update: September 2013.

  17. CMS Centres Worldwide - a New Collaborative Infrastructure

    International Nuclear Information System (INIS)

    Taylor, Lucas

    2011-01-01

    The CMS Experiment at the LHC has established a network of more than fifty inter-connected 'CMS Centres' at CERN and in institutes in the Americas, Asia, Australasia, and Europe. These facilities are used by people doing CMS detector and computing grid operations, remote shifts, data quality monitoring and analysis, as well as education and outreach. We present the computing, software, and collaborative tools and videoconferencing systems. These include permanently running 'telepresence' video links (hardware-based H.323, EVO and Vidyo), Webcasts, and generic Web tools such as CMS-TV for broadcasting live monitoring and outreach information. Being Web-based and experiment-independent, these systems could easily be extended to other organizations. We describe the experiences of using CMS Centres Worldwide in the CMS data-taking operations as well as for major media events with several hundred TV channels, radio stations, and many more press journalists simultaneously around the world.

  18. The PAUCam readout electronics system

    Science.gov (United States)

    Jiménez, Jorge; Illa, José M.; Cardiel-Sas, Laia; de Vicente, Juan; Castilla, Javier; Casas, Ricard

    2016-08-01

    The PAUCam is an optical camera with a wide field of view of 1 deg x 1 deg and up to 46 narrow and broad band filters. The camera is already installed on the William Herschel Telescope (WHT) in the Canary Islands, Spain and successfully commissioned during the first period of 2015. The paper presents the main results from the readout electronics commissioning tests and include an overview of the whole readout electronics system, its configuration and current performance.

  19. Readout scheme for the Baby-MIND detector

    CERN Document Server

    Noah, Etam; Cadoux, F; Favre, Y; Martinez, B; Nicola, L; Parsa, S; Rayner, M; Antonova, M; Fedotov, S; Izmaylov, A; Kleymenova, A; Khabibullin, M; Khotyantsev, A; Kudenko, Y; Likhacheva, V; Mefodiev, A; Mineev, O; Ovsiannikova, T; Shaykhiev, A; Suvorov, S; Yershov, N; Tsenov, R

    2016-01-01

    A readout scheme has been designed for the plastic scintillator bars of the Baby-MIND detector modules. This spectrometer will measure momentum and identify the charge of 1 GeV/c muons with magnetized iron plates interleaved with detector modules. One challenge the detector aims to address is that of keeping high charge identification efficiencies for momenta below 1 GeV/c where multiple scattering in the iron plates degrades momentum resolution. A front-end board has been developed, with 3 CITIROC readout chips per board and up to 96 channels. Hamamatsu MPPCs type S12571-025C photosensors were chosen for readout of wavelength shifting fibers embedded in plastic scintillators. Procurement of the MPPCs has been carried out to instrument 3000 channels in total. Design choices and first results of this readout scheme are presented.

  20. 42 CFR 460.20 - Notice of CMS determination.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Notice of CMS determination. 460.20 Section 460.20... ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.20 Notice of CMS determination. (a... application to CMS, CMS takes one of the following actions: (1) Approves the application. (2) Denies the...

  1. CMS Young Researchers Award 2013 and Fundamental Physics Scholars Award from the CMS Experiment

    CERN Multimedia

    Lapka, Marzena

    2014-01-01

    Photo 2: CMS Fundamental Physics Scholars (FPSs) 1st prize: Joosep Pata, from Estonian National Institue of Chemical Physics and Biophysics / Photo 1 and 3: CMS Young Researchers Award. From left to right: Guido Tonelli, Colin Bernet, Andre David, Oliver Gutsche, Dmytro Kovalskyi, Andrea Petrucci, Joe Incandela and Jim Virdee

  2. Design studies for the Phase II upgrade of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Orimoto, Toyoko Jennifer

    2016-01-01

    The High Luminosity LHC (HL-LHC) will provide unprecedented instantaneous and integrated luminosity. The lead tungstate crystals forming the barrel part of the Electromagnetic Calorimeter (ECAL) of the Compact Muon Solenoid (CMS) will still perform well, even after the expected integrated luminosity of 3000fb-1 at the end of HL-LHC. The avalanche photodiodes (APDs) used to detect the scintillation light will also continue to be operational, although there will be some increase in noise due to radiation-induced dark currents. This will be mitigated by reducing the barrel operating temperature during HL-LHC running.The front-end electronics of the ECAL barrel will be replaced, in order to remove existing constraints on trigger rate and latency and to provide additional capability to fully exploit the higher luminosity delivered by the HL-LHC. New developments in high-speed optical links will allow single-crystal readout at 40 MHz to upgraded off-detector processors, allowing maximum flexibility and enhanced tri...

  3. 42 CFR 422.510 - Termination of contract by CMS.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Termination of contract by CMS. 422.510 Section 422... Advantage Organizations § 422.510 Termination of contract by CMS. (a) Termination by CMS. CMS may at any time terminate a contract if CMS determines that the MA organization meets any of the following: (1...

  4. Novel trigger-capable modules for the future CMS tracking detector and inclusive top quark pair production cross section at √(s)=13 TeV

    International Nuclear Information System (INIS)

    Harb, Ali

    2017-07-01

    This work covers two important aspects in the field of high-energy physics; detector development and physics data analysis. The first part of this thesis is devoted to the detector development activities for the Phase-II upgrade of the Compact Muon Solenoid (CMS) experiment's outer tracking detector. To cope with the increased luminosity during the high-luminosity era of the Large Hadron Collider (LHC), it is foreseen to replace the existing tracking system of CMS with an entirely new system. Owing to a novel module concept called the p_T-module, the upgraded tracking system will be able to provide first level trigger information by means of an on-board momentum discrimination logic. This will be achieved using a new readout chip, the so-called CMS Binary Chip (CBC). The very first test beam measurement using p_T-module prototypes, equipped with the CBC chip is presented and discussed. The obtained results serve as a proof-of-concept for such modules and shows that the CBC performs as expected. In the second part of this thesis, the measurement of the top quark pair production cross section is addressed. The measurement is performed using 2.2 fb"-"1 of data collected by the CMS detector at a center-of-mass energy of 13 TeV. Results are shown in the eμ di-lepton channel, and for the first time at such energy, in the ee and μμ channels. With an improved treatment of systematic uncertainties, the results in all three channels are found to be in agreement with the theoretical predictions.

  5. Rutherford X-ray spectrometer readout

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1978-07-01

    Rutherford electronic X-ray spectrometer readout is based on the combination of two established techniques (a) the detection and location of soft X-rays by means of multichannel electron multiplier arrays (MCP's), and (b) the electronic readout of charge distributions (generally in multi-wire proportional counters) by means of the delay line techniques. In order for the latter device to function well a charge signal of approximately 10 6 electrons must be available to the delay line wand. This is achieved in the present device by means of two cascaded MCP's which can produce electron gains up to approximately 10 8 , and so operate the delay line from the single electron pulses generated at the front face of an MCP by a soft X-ray. The delay line readout technique was chosen because of its simplicity (both in terms of the necessary hardware and the associated electronics), robustness, and ease of implementation. In order to achieve the target spatial resolution of 50 μm (fwhm) or 20 μm (standard deviation) it was necessary to adapt the charge collection system so that the readout takes place from a length of delay line 200 mm long. The general layout of the system and the functions of the electronic circuits are described. Performance testing, setting up procedures and trouble shooting of the system are discussed. (U.K.)

  6. 42 CFR 423.509 - Termination of contract by CMS.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Termination of contract by CMS. 423.509 Section 423... Contracts with Part D plan sponsors § 423.509 Termination of contract by CMS. (a) Termination by CMS. CMS may at any time terminate a contract if CMS determines that the Part D plan sponsor meets any of the...

  7. 42 CFR 422.210 - Assurances to CMS.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Assurances to CMS. 422.210 Section 422.210 Public...) MEDICARE PROGRAM MEDICARE ADVANTAGE PROGRAM Relationships With Providers § 422.210 Assurances to CMS. (a) Assurances to CMS. Each organization will provide assurance satisfactory to the Secretary that the...

  8. The CMS Computing Model

    International Nuclear Information System (INIS)

    Bonacorsi, D.

    2007-01-01

    The CMS experiment at LHC has developed a baseline Computing Model addressing the needs of a computing system capable to operate in the first years of LHC running. It is focused on a data model with heavy streaming at the raw data level based on trigger, and on the achievement of the maximum flexibility in the use of distributed computing resources. The CMS distributed Computing Model includes a Tier-0 centre at CERN, a CMS Analysis Facility at CERN, several Tier-1 centres located at large regional computing centres, and many Tier-2 centres worldwide. The workflows have been identified, along with a baseline architecture for the data management infrastructure. This model is also being tested in Grid Service Challenges of increasing complexity, coordinated with the Worldwide LHC Computing Grid community

  9. Soft QCD at CMS and ATLAS

    CERN Document Server

    Starovoitov, Pavel; The ATLAS collaboration

    2018-01-01

    A short overview of the recent soft QCD results from the ATLAS and CMS collaborations is presented. The inelastic cross section measurement by CMS at 13 TeV is summarised. The contribution of the diffractive processes to the very forward photon spectra studied by ATLAS and LHCf is discussed. The ATLAS measurements of the exclusive two-photon production of the muon pairs is presented and compared to the previous ATLAS and CMS results.

  10. D-Zero muon readout electronics design

    International Nuclear Information System (INIS)

    Baldin, B.; Hansen, S.; Los, S.; Matveev, M.; Vaniev, V.

    1996-11-01

    The readout electronics designed for the D null Muon Upgrade are described. These electronics serve three detector subsystems and one trigger system. The front-ends and readout hardware are synchronized by means of timing signals broadcast from the D null Trigger Framework. The front-end electronics have continuously running digitizers and two levels of buffering resulting in nearly deadtimeless operation. The raw data is corrected and formatted by 16- bit fixed point DSP processors. These processors also perform control of the data buffering. The data transfer from the front-end electronics located on the detector platform is performed by serial links running at 160 Mbit/s. The design and test results of the subsystem readout electronics and system interface are discussed

  11. 23 CFR 500.109 - CMS.

    Science.gov (United States)

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false CMS. 500.109 Section 500.109 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRANSPORTATION INFRASTRUCTURE MANAGEMENT MANAGEMENT AND MONITORING SYSTEMS Management Systems § 500.109 CMS. (a) For purposes of this part, congestion means the level at...

  12. Overview of the Calorimeter Readout Upgrades

    CERN Document Server

    Straessner, Arno; The ATLAS collaboration

    2018-01-01

    The ATLAS and CMS calorimeter electronics will be upgraded for the HL-LHC data taking phase to cope with higher event pile-up and to allow improved trigger strategies. This presentations gives an overview of the ongoing developments for the CMS barrel calorimeters and the ATLAS LAr and Tile calorimeters.

  13. CMS - The Compact Muon Solenoid

    CERN Multimedia

    Bergauer, T; Waltenberger, W; Kratschmer, I; Treberer-treberspurg, W; Escalante del valle, A; Andreeva, I; Innocente, V; Camporesi, T; Malgeri, L; Marchioro, A; Moneta, L; Weingarten, W; Beni, N T; Cimmino, A; Rovere, M; Jafari, A; Lange, C G; Vartak, A P; Gilbert, A J; Pantaleo, F; Reis, T; Cucciati, G; Alipour tehrani, N; Stakia, A; Fallavollita, F; Pizzichemi, M; Rauco, G; Zhang, S; Hu, T; Yazgan, E; Zhang, H; Thomas-wilsker, J; Reithler, H K V; Philipps, B; Merschmeyer, M K; Heidemann, C A; Mukherjee, S; Geenen, H; Kuessel, Y; Weingarten, S; Gallo, E; Schwanenberger, C; Walsh bastos rangel, R; Beernaert, K S; De wit, A M; Elwood, A C; Connor, P; Lelek, A A; Wichmann, K H; Myronenko, V; Kovalchuk, N; Bein, S L; Dreyer, T; Scharf, C; Quast, G; Dierlamm, A H; Barth, C; Mol, X; Kudella, S; Schafer, D; Schimassek, R R; Matorras, F; Calderon tazon, A; Garcia ferrero, J; Bercher, M J; Sirois, Y; Callier, S; Depasse, P; Laktineh, I B; Grenier, G; Boudoul, G; Heath, G P; Hartley, D A; Quinton, S; Tomalin, I R; Harder, K; Francis, V B; Thea, A; Zhang, Z; Loukas, D; Hernath, S T; Naskar, K; Colaleo, A; Maggi, G P; Maggi, M; Loddo, F; Calabria, C; Campanini, R; Cuffiani, M; D'antone, I; Grandi, C; Navarria, F; Guiducci, L; Battilana, C; Tosi, N; Gulmini, M; Meola, S; Longo, E; Meridiani, P; Marzocchi, B; Schizzi, A; Cho, S; Ha, S; Kim, D H; Kim, G N; Md halid, M F B; Yusli, M N B; Dominik, W M; Bunkowski, K; Olszewski, M; Byszuk, A P; Rasteiro da silva, J C; Varela, J; Leong, Q; Sulimov, V; Vorobyev, A; Denisov, A; Murzin, V; Egorov, A; Lukyanenko, S; Postoev, V; Pashenkov, A; Solovey, A; Rubakov, V; Troitsky, S; Kirpichnikov, D; Lychkovskaya, N; Safronov, G; Fedotov, A; Toms, M; Barniakov, M; Olimov, K; Fazilov, M; Umaraliev, A; Dumanoglu, I; Bakirci, N M; Dozen, C; Demiroglu, Z S; Isik, C; Zeyrek, M; Yalvac, M; Ozkorucuklu, S; Chang, Y; Dolgopolov, A; Gottschalk, E E; Maeshima, K; Heavey, A E; Kramer, T; Kwan, S W L; Taylor, L; Tkaczyk, S M; Mokhov, N; Marraffino, J M; Mrenna, S; Yarba, V; Banerjee, B; Elvira, V D; Gray, L A; Holzman, B; Dagenhart, W; Canepa, A; Ryu, S C; Strobbe, N C; Adelman-mc carthy, J K; Contescu, A C; Andre, J O; Wu, J; Dittmer, S J; Bucinskaite, I; Zhang, J; Karchin, P E; Thapa, P; Zaleski, S G; Gran, J L; Wang, S; Zilizi, G; Raics, P P; Bhardwaj, A; Naimuddin, M; Smiljkovic, N; Stojanovic, M; Brandao malbouisson, H; De oliveira martins, C P; Tonelli manganote, E J; Medina jaime, M; Thiel, M; Laurila, S H; Graehling, P; Tonon, N; Blekman, F; Postiau, N J S; Leroux, P J; Van remortel, N; Janssen, X J; Di croce, D; Aleksandrov, A; Shopova, M F; Dogra, S M; Shinoda, A A; Arce, P; Daniel, M; Navarrete marin, J J; Redondo fernandez, I; Guirao elias, A; Cela ruiz, J M; Lottin, J; Gras, P; Kircher, F; Levesy, B; Payn, A; Guilloux, F; Negro, G; Leloup, C; Pasztor, G; Panwar, L; Bhatnagar, V; Bruzzi, M; Sciortino, S; Starodubtsev, O; Azzi, P; Conti, E; Lacaprara, S; Margoni, M; Rossin, R; Tosi, M; Fano', L; Lucaroni, A; Biino, C; Dattola, D; Rotondo, F; Ballestrero, A; Obertino, M M; Kiani, M B; Paterno, A; Magana villalba, R; Ramirez garcia, M; Reyes almanza, R; Gorski, M; Wrochna, G; Bluj, M J; Zarubin, A; Nozdrin, M; Ladygin, V; Malakhov, A; Golunov, A; Skrypnik, A; Sotnikov, A; Evdokimov, N; Tiurin, V; Lokhtin, I; Ershov, A; Platonova, M; Tyurin, N; Slabospitskii, S; Talov, V; Belikov, N; Ryazanov, A; Chao, Y; Tsai, J; Foord, A; Wood, D R; Orimoto, T J; Luckey, P D; Jaditz, S H; Stephans, G S; Darlea, G L; Di matteo, L; Maier, B; Trovato, M; Bhattacharya, S; Roberts, J B; Padley, P B; Tu, Z; Rorie, J T; Clarida, W J; Tiras, E; Khristenko, V; Cerizza, G; Pieri, M; Krutelyov, V; Saiz santos, M D; Klein, D S; Derdzinski, M; Murray, M J; Gray, J A; Minafra, N; Castle, J R; Bowen, J L S; Buterbaugh, K; Morrow, S I; Bunn, J; Newman, H; Spiropulu, M; Balcas, J; Lawhorn, J M; Thomas, S D; Panwalkar, S M; Kyriacou, S; Xie, Z; Ojalvo, I R; Salfeld-nebgen, J; Laird, E M; Wimpenny, S J; Yates, B R; Perry, T M; Schiber, C C; Diaz, D C; Uniyal, R; Mesic, B; Kolosova, M; Snow, G R; Lundstedt, C; Johnston, D; Zvada, M; Weitzel, D J; Damgov, J V; Cowden, C S; Giammanco, A; David, P N Y; Zobec, J; Cabrera jamoulle, J B; Daubie, E; Nash, J A; Evans, L; Hall, G; Nikitenko, A; Ryan, M J; Huffman, M A J; Styliaris, E; Evangelou, I; Sharan, M K; Roy, A; Rout, P K; Kalbhor, P N; Bagliesi, G; Braccini, P L; Ligabue, F; Boccali, T; Rizzi, A; Minuti, M; Oh, S; Kim, J; Sen, S; Boz evinay, M; Xiao, M; Hung, W T; Jensen, F O; Mulholland, T D; Kumar, A; Jones, M; Roozbahani, B H; Neu, C C; Thacker, H B; Wolfe, E M; Jabeen, S; Gilmore, J; Winer, B L; Rush, C J; Luo, W; Alimena, J M; Ko, W; Lander, R; Broadley, W H; Shi, M; Furic, I K; Low, J F; Bortignon, P; Alexander, J P; Zientek, M E; Conway, J V; Padilla fuentes, Y L; Florent, A H; Bravo, C B; Crotty, I M; Wenman, D L; Sarangi, T R; Ghabrous larrea, C; Gomber, B; Smith, N C; Long, K D; Roberts, J M; Hildreth, M D; Jessop, C P; Karmgard, D J; Loukas, N; Ferbel, T; Zielinski, M A; Cooper, S I; Jung, A; Van driessche, W G M; Fagot, A; Vermassen, B; Valchkova-georgieva, F K; Dimitrov, D S; Roumenin, T S; Podrasky, V; Re, V; Zucca, S; De canio, F; Romaniuk, R; Teodorescu, L; Krofcheck, D; Anderson, N G; Bell, S T; Salazar ibarguen, H A; Kudinov, V; Onishchenko, S; Naujikas, R; Lyubynskiy, V; Sobolev, O; Khan, M S; Adeel-ur-rehman, A; Hassan, Q U; Ali, I; Kreuzer, P K; Robson, A J; Gadrat, S G; Ivanov, A; Mendis, D; Da silva di calafiori, D R; Zeinali, M; Behnamian, H; Moroni, L; Malvezzi, S; Park, I; Pastika, N J; Oropeza barrera, C; Elkhateeb, E A A; Elmetenawee, W; Mohammed, Y; Tayel, E S A; Mcclatchey, R H; Kovacs, Z; Munir, K; Odeh, M; Magradze, E; Oikashvili, B; Shingade, P; Shukla, R A; Banerjee, S; Kumar, S; Jashal, B K; Grzanka, L; Adam, W; Ero, J; Fabjan, C; Jeitler, M; Rad, N K; Auffray hillemanns, E; Charkiewicz, A; Fartoukh, S; Garcia de enterria adan, D; Girone, M; Glege, F; Loos, R; Mannelli, M; Meijers, F; Sciaba, A; Meschi, E; Ricci, D; Petrucciani, G; Daguin, J; Vazquez velez, C; Karavakis, E; Nourbakhsh, S; Rabady, D S; Ceresa, D; Karacheban, O; Beguin, M; Kilminster, B J; Ke, Z; Meng, X; Zhang, Y; Tao, J; Romeo, F; Spiezia, A; Cheng, L; Zhukov, V; Feld, L W; Autermann, C T; Fischer, R; Erdweg, S; Kress, T H; Dziwok, C; Hansen, K; Schoerner-sadenius, T M; Marfin, I; Keaveney, J M; Diez pardos, C; Muhl, C W; Asawatangtrakuldee, C; Defranchis, M M; Asmuss, J P; Poehlsen, J A; Stober, F M H; Vormwald, B R; Kripas, V; Gonzalez vazquez, D; Kurz, S T; Niemeyer, C; Rieger, J O; Borovkov, A; Shvetsov, I; Sieber, G; Caspart, R; Iqbal, M A; Sander, O; Metzler, M B; Ardila perez, L E; Ruiz jimeno, A; Fernandez garcia, M; Scodellaro, L; Gonzalez sanchez, J F; Curras rivera, E; Semeniouk, I; Ochando, C; Bedjidian, M; Giraud, N A; Mathez, H; Zoccarato, Y D; Ianigro, J; Galbit, G C; Flacher, H U; Shepherd-themistocleous, C H; French, M J; Hill, J A; Jones, L L; Markou, A; Bencze, G L; Mishra, D K; Netrakanti, P K; Jha, V; Chudasama, R; Katta, S; Venditti, R; Cristella, L; Braibant-giacomelli, S; Dallavalle, G; Fabbri, F; Codispoti, G; Borgonovi, L; Caponero, M A; Berti, L; Fienga, F; Dafinei, I; Organtini, G; Del re, D; Pettinacci, V; Park, S K; Lee, K S; Kang, M; Kim, B; Park, H K; Kong, D J; Lee, S; Pak, S I; Zolkapli, Z B; Konecki, M A; Walczak, M B; Bargassa, P; Viegas guerreiro leonardo, N T; Levchenko, P; Orishchin, E; Suvorov, V; Uvarov, L; Gruzinskii, N; Pristavka, A; Kozlov, V; Radovskaia, A; Solovey, A; Kolosov, V; Vlassov, E; Parygin, P; Tumasyan, A; Topakli, H; Boran, F; Akin, I V; Oz, C; Gulmez, E; Atakisi, I O; Bakken, J A; Govi, G M; Lewis, J D; Shaw, T M; Bailleux, D; Stoynev, S E; Sexton-kennedy, E M; Huang, C; Lincoln, D W; Roser, R; Ito, A; Adams, M R; Apanasevich, L; Varelas, N; Sandoval gonzalez, I D; Hangal, D A; Yoo, J H; Ovcharova, A K; Bradmiller-feld, J W; Amin, N J; Miller, M P; Patterson, A S; Sharma, R K; Santoro, A; Lassila-perini, K M; Tuominiemi, J; Voutilainen, M A; Wu, X; Gross, L O; Le bihan, A; Fuks, B; Kieffer, E; Pansanel, J; Jansova, M; D'hondt, J; Abuzeid hassan, S A; Bilin, B; Beghin, D; Soultanov, G; Vankov, I D; Konstantinov, P B; Marra da silva, J; De souza santos, A; Arruda ramalho, L; Renker, D; Erdmann, W; Molinero vela, A; Fernandez bedoya, C; Bachiller perea, I; Chipaux, R; Faure, J D; Hamel de monchenault, G; Mandjavidze, I; Rander, J; Ferri, F; Leroy, C L; Machet, M; Nagy, M I; Felcini, M; Kaur, S; Saizu, M A; Civinini, C; Latino, G; Checchia, P; Ronchese, P; Vanini, S; Fantinel, S; Cecchi, C; Leonardi, R; Arneodo, M; Ruspa, M; Pacher, L; Rabadan trejo, R I; Mondragon herrera, C A; Golutvin, I; Zhiltsov, V; Melnichenko, I; Mjavia, D; Cheremukhin, A; Zubarev, E; Kalagin, V; Alexakhin, V; Mitsyn, V; Shulha, S; Vishnevskiy, A; Gavrilenko, M; Boos, E E; Obraztsov, S; Dubinin, M; Demiyanov, A; Dudko, L; Azhgirey, I; Chikilev, O; Turchanovich, L; Rurua, L; Hou, G W; Wang, M; Chang, P; Kumar, A; Liau, J; Lazic, D; Lawson, P D; Zou, D; Wisecarver, A L; Sumorok, K C; Klute, M; Lee, Y; Iiyama, Y; Velicanu, D A; Mc ginn, C; Abercrombie, D R; Tatar, K; Hahn, K A; Nussbaum, T W; Southwick, D C; Cittolin, S; Martin, T; Welke, C V; Wilson, G W; Baringer, P S; Sanders, S J; Mcbrayer, W J; Engh, D J; Sheldon, P D; Gurrola, A; Velkovska, J A; Melo, A M; Padeken, K O; Johnson, C N; Ni, H; Montalvo, R J; Heindl, M D; Ferguson, T; Vogel, H; Mudholkar, T K; Elmer, P; Tully, C; Luo, J; Hanson, G; Jandir, P S; Askew, A W; Kadija, K; Dimovasili, E; Attikis, A; Vasilas, I; Chen, G; Bockelman, B P; Kamalieddin, R; Barrefors, B P; Farleigh, B S; Akchurin, N; Demin, P; Pavlov, B A; Petkov, P S; Goranova, R; Tomsa, J; Lyons, L; Buchmuller, O; Magnan, A; Laner ogilvy, C; Di maria, R; Dutta, S; Thakur, S; Bettarini, S; Bosi, F; Giassi, A; Massa, M; Calzolari, F; Androsov, K; Lee, H; Komurcu, Y; Kim, D W; Wagner, S R; Perloff, A S; Rappoccio, S R; Harrington, C I; Baden, A R; Ricci-tam, F; Kamon, T; Rathjens, D; Pernie, L; Larsen, D; Ji, W; Pellett, D E; Smith, J; Acosta, D E; Field, R D; Yelton, J M; Kotov, K; Wang, S; Smolenski, K W; Mc coll, N W; Dasu, S R; Lanaro, A; Cook, J R; Gorski, T A; Buchanan, J J; Jain, S; Musienko, Y; Taroni, S; Meng, H; Siddireddy, P K; Xie, W; Rott, C; Benedetti, D; Everett, A A; Schulte, J; Mahakud, B; Ryckbosch, D D E; Crucy, S; Cornelis, T G M; Betev, B; Dimov, H; Raykov, P A; Uzunova, D G; Mihovski, K T; Mechinsky, V; Makarenko, V; Yermak, D; Yevarouskaya, U; Salvini, P; Manghisoni, M; Fontaine, J; Agram, J; Palinkas, J; Reid, I D; Bell, A J; Clyne, M N; Zavodchikov, S; Veelken, C; Kannike, K; Dewanjee, R K; Skarupelov, V; Piibeleht, M; Ehataht, K; Chang, S; Kuchinski, P; Bukauskas, L; Zhmurin, P; Kamal, A; Mubarak, M; Asghar, M I; Ahmad, N; Muhammad, S; Mansoor-ul-islam, S; Saddique, A; Waqas, M; Irshad, A; Veckalns, V; Toda, S; Choi, Y K; Yu, I; Hwang, C; Yumiceva, F X; Djambazov, L; Meinhard, M T; Becker, R J U; Grimm, O; Wallny, R S; Tavolaro, V R; Eller, P D; Meister, D; Paktinat mehdiabadi, S; Chenarani, S; Dini, P; Leporini, R; Dinardo, M; Brianza, L; Hakkarainen, U T; Parashar, N; Malik, S; Ramirez vargas, J E; Dharmaratna, W; Noh, S; Uang, A J; Kim, J H; Lee, J S H; Jeon, D; You, Z; Assran, Y; Elgammal, S; Ellithi kamel, A Y; Nayak, A K; Dash, D; Koca, N; Kothekar, K K; Karnam, R; Patil, M R; Torims, T; Hoch, M; Schieck, J R; Valentan, M; Spitzbart, D; Lucio alves, F L; Blanchot, G; Gill, K A; Orsini, L; Petrilli, A; Sharma, A; Tsirou, A; Deile, M; Hudson, D A; Gutleber, J; Folch, R; Tropea, P; Cerminara, G; Vichoudis, P; Pardo, T; Sabba, H; Selvaggi, M; Verzetti, M; Ngadiuba, J; Kornmayer, A; Niedziela, J; Aarrestad, T K; He, K; Li, B; Huang, Q; Pierschel, G; Esch, T; Louis, D; Quast, T; Nowack, A S; Beissel, F; Borras, K A; Mankel, R; Pitzl, D D; Kemp, Y; Meyer, A B; Krucker, D B; Mittag, G; Burgmeier, A; Lenz, T; Arndt, T M; Pflitsch, S K; Danilov, V; Dominguez damiani, D; Cardini, A; Kogler, R; Troendle, D C; Aggleton, R C; Lange, J; Reimers, A C; De boer, W; Weber, M M; Theel, A; Mozer, M U; Wayand, S; Harrendorf, M A; Harbaum, T R; El morabit, K; Marco, J; Rodrigo, T; Vila alvarez, I; Lopez garcia, A; Rembser, J; Mathieu, A; Kurca, T; Mirabito, L; Verdier, P; Combaret, C; Newbold, D M; Smith, V; Brooke, J J; Metson, S; Coughlan, J A; Torbet, M J; Belyaev, A; Kyriakis, A; Horvath, D; Veszpremi, V; Topkar, A; Selvaggi-maggi, G; Nuzzo, S V; Romano, F; Marangelli, B; Spinoso, V; Lezki, S; Castro, A; Rovelli, T; Brigliadori, L; Bianco, S; Fabbricatore, P; Farinon, S; Musenich, R; Ferro, F; Gozzelino, A; Buontempo, S; Casolaro, P; Paramatti, R; Vignati, M; Belforte, S; Hong, B; Roh, Y J; Choi, S Y; Son, D; Yang, Y C; Butanov, K; Kotobi, A; Krolikowski, J; Pozniak, K T; Misiura, M; Seixas, J C; Jain, A K; Nemallapudi, M V; Shchipunov, L; Lebedev, V; Skorobogatov, V; Klimenko, K; Terkulov, A; Kirakosyan, M; Azarkin, M; Krasnikov, N; Stepanova, L; Gavrilov, V; Spiridonov, A; Semenov, S; Krokhotin, A; Rusinov, V; Chistov, R; Zhemchugov, E; Nishonov, M; Hmayakyan, G; Khachatryan, V; Ozdemir, K; Ozturk, S; Tali, B; Kangal, E E; Turkcapar, S; Zorbakir, I S; Aliyev, T; Demir, D A; Liu, W; Apollinari, G; Osborne, I; Genser, K; Lammel, S; Whitmore, J; Mommsen, R; Apyan, A; Badgett jr, W F; Atac, M; Joshi, U P; Vidal, R A; Giacchetti, L A; Merkel, P; Johnson, M E; Soha, A L; Tran, N V; Rapsevicius, V; Hirschauer, J F; Voirin, E; Altunay cheung, M; Liu, T T; Mosquera morales, J F; Gerber, C E; Chen, X; Clarke, C J; Stuart, D D; Franco sevilla, M; Marsh, B J; Shivpuri, R K; Adzic, P; De almeida pacheco, M A; Matos figueiredo, D; De queiroz franco, A B; Melo de almeida, M; Bernardo valadao, R; Linden, T; Tuovinen, E V; Jarvinen, T T; Siikonen, H J L; Ripp-baudot, I L; Richer, M; Vander velde, C; Randle-conde, A S; Dong, J; Van haevermaet, H J H; Dimitrov, L; De paula bianchini, C; Muller cascadan, A; Kotlinski, B; Alcaraz maestre, J; Josa mutuberria, M I; Gonzalez lopez, O; Marin munoz, J; Puerta pelayo, J; Rodriguez vazquez, J J; Denegri, D; Jarry, P; Rosowsky, A; Tsipolitis, G; Grunewald, M; Singh, J; Chawla, R; Gupta, R; Giordano, F; Parrini, G; Russo, L; Dosselli, U; Mazzucato, M; Verlato, M; Wulzer, A; Traldi, S; Bortolato, D; Biasini, M; Bilei, G M; Movileanu, M; Santocchia, A; Mariani, V; Mariotti, C; Monaco, V; Accomando, E; Pinna angioni, G L; Boimska, B; Yuldashev, B; Kamenev, A; Belotelov, I; Filozova, I; Bunin, P; Golovanov, G; Gribushin, A; Kaminskiy, A; Volkov, P; Vorotnikov, G; Bityukov, S; Kryshkin, V; Petrov, V; Volkov, A; Troshin, S; Levin, A; Sumaneev, O V; Kalinin, A; Kulagin, N; Mandrik, P; Lin, C; Kovalskyi, D; Demiragli, Z; Hsu, D G; Michlin, B A; Fountain, M; Debbins, P A; Durgut, S; Tadel, M; White, A; Molina-perez, J A; Dost, J M; Boren, S S; Klein, A; Bhatti, A; Mesropian, C; Wilkinson, R; Xie, S; Marlow, D R; Jindal, P; Palmer, C A; Narain, M; Berry, E A; Usai, E; Korotkov, A L; Strossman, W; Kennedy, E; Burt, K F; Saha, A; Starodumov, A; Mavromanolakis, G; Nicolaou, C; Mao, Y; Claes, D R; Sill, A F; Lamichhane, K; Antunovic, Z; Piotrzkowski, K; Bondu, O; Dimitrov, A A; Albajar, C; Torga teixeira, R F; Iles, G M; Borg, J; Cripps, N A; Uchida, K; Fayer, S W; Wright, J C; Kokkas, P; Manthos, N; Bhattacharya, S; Nandan, S; Bellazzini, R; Carboni, A; Arezzini, S; Yang, U K; Roskes, J; Corcodilos, L A; Nauenberg, U; Johnson, D; Kharchilava, A; Mc lean, C A; Cox, B B; Hirosky, R J; Cummings, G E; Skuja, A; Bard, R L; Mueller, R D; Puigh, D M; Chertok, M B; Calderon de la barca sanchez, M; Gunion, J F; Vogt, R; Conway, R T; Gearhart, J W; Band, R E; Kukral, O; Korytov, A; Fu, Y; Madorsky, A; Brinkerhoff, A W; Rinkevicius, A; Mcdermott, K P; Tao, Z; Bellis, M; Gronberg, J B; Hauser, J; Bachtis, M; Kubic, J; Nash, W A; Greenler, L S; Caillol, C S; Woods, N; De jesus pardal vicente, M; Trembath-reichert, S; Singovski, A; Wolf, M; Smith, G N; Bucci, R E; Reinsvold, A C; Rupprecht, N C; Taus, R A; Buccilli, A T; Kroeger, R S; Reidy, J J; Barnes, V E; Kress, M K; Thieman, J R; Mccartin, J W; Gul, M; Khvastunov, I; Georgiev, I G; Biselli, A; Berzano, U; Vai, I; Braghieri, A; Cardoso lopes, R; Cuevas maestro, J F; Palencia cortezon, J E; Reucroft, S; Bheesette, S; Butler, A; Ivanov, A; Mizelkov, M; Kashpydai, O; Kim, J; Janulis, M; Zemleris, V; Ali, A; Ahmed, U S; Awan, M I; Lee, J; Dissertori, G; Pauss, F; Musella, P; Gomez espinosa, T A; Pigazzini, S; Vesterbacka olsson, M L; Klijnsma, T; Khakzad, M; Arfaei, H; Bonesini, M; Ciriolo, V; Gomez moreno, B; Linares garcia, L E; Bae, S; Ko, B; Hatakeyama, K; Mahmoud mohammed, M A; Aly, A; Ahmad, A; Bahinipati, S; Kim, T J; Goh, J; Fang, W; Kemularia, O; Melkadze, A; Sharma, S; Rane, A P; Ayala amaya, E R; Akle, B; Palomo pinto, F R; Madlener, T; Spanring, M; Pol, M E; Alda junior, W L; Rodrigues simoes moreira, P; Kloukinas, K; Onnela, A T O; Passardi, G; Perez, E F; Postema, W J; Petagna, P; Gaddi, A; Vieira de castro ferreira da silva, P M; Gastal, M; Dabrowski, A E; Mersi, S; Bianco, M; Alandes pradillo, M; Chen, Y; Kieseler, J; Bawej, T A; Roedne, L T; Hugo, G; Baschiera, M; Loiseau, T L; Donato, S; Wang, Y; Liu, Z; Yue, X; Teng, C; Wang, Z; Liao, H; Zhang, X; Chen, Y; Ahmad, M; Zhao, H; Qi, F; Li, B; Raupach, F; Tonutti, M P; Radziej, M; Fluegge, G; Haj ahmad, W; Kunsken, A; Roy, D M; Ziemons, T; Behrens, U; Henschel, H M; Kleinwort, C H; Dammann, D J; Van onsem, G P; Contreras campana, C J; Penno, M; Haranko, M; Singh, A; Turkot, O; Scheurer, V; Schleper, P; Schwandt, J; Schwarz, D; Hartmann, F; Muller, T; Mallows, S; Funke, D; Baselga bacardit, M; Mitra, S; Martinez rivero, C; Moya martin, D; Hidalgo villena, S; Chazin quero, B; Mine, P M G; Poilleux, P R; Salerno, R A; Martin perez, C; Amendola, C; Caponetto, L; Pugnere, D Y; Giraud, Y A N; Sordini, V; Grimes, M A; Burns, D J P; Harper, S J; Hajdu, C; Vami, T A; Dutta, D; Pant, L M; Kumar, V; Sarin, P; Di florio, A; Giacomelli, P; Montanari, A; Siroli, G P; Robutti, E; Maron, G; Fabozzi, F; Galati, G; Rovelli, C I; Della ricca, G; Vazzoler, F; Oh, Y D; Park, W H; Kwon, K H; Choi, J; Kalinowski, A; Santos amaral, L C; Di francesco, A; Velichko, G; Smirnov, I; Kozlov, V; Vavilov, S; Kirianov, A; Dremin, I; Rusakov, S; Nechitaylo, V; Kovzelev, A; Toropin, A; Anisimov, A; Barniakov, A; Gasanov, E; Eskut, E; Polatoz, A; Karaman, T; Zorbilmez, C; Bat, A; Tok, U G; Dag, H; Kaya, O; Tekten, S; Lin, T; Abdoulline, S; Bauerdick, L; Denisov, D; Gingu, C; Green, D; Nahn, S C; Prokofiev, O E; Strait, J B; Los, S; Bowden, M; Tanenbaum, W M; Guo, Y; Dykstra, D W; Mason, D A; Chlebana, F; Cooper, W E; Anderson, J M K; Weber, H A; Christian, D C; Alyari, M F; Diaz cruz, J A; Wang, M; Berry, D R; Siehl, K F; Poudyal, N; Kyre, S A; Mullin, S D; George, C; Szabo, Z; Malhotra, S; Milosevic, J; Prado da silva, W L; Martins mundim filho, L; Sanchez rosas, L J; Karimaki, V J; Toor, S Z; Karadzhinova, A G; Maazouzi, C; Van hove, P J; Hosselet, J; Goorens, R; Brun, H L; Kalsi, A K; Wang, Q; Vannerom, D; Antchev, G; Iaydjiev, P S; Mitev, G M; Amadio, G; Langenegger, U; Kaestli, H C; Meier, B; Fernandez ramos, J P; Besancon, M; Fabbro, B; Ganjour, S; Locci, E; Gevin, O; Suranyi, O; Bansal, S; Kumar, R; Sharma, S; Tuve, C N; Tricomi, A; Meschini, M; Paoletti, S; Sguazzoni, G; Gori, V; Carlin, R; Dal corso, F; Simonetto, F; Torassa, E; Zumerle, G; Borsato, E; Gonella, F; Dorigo, A; Larsen, H; Peroni, C; Trapani, P P; Buarque franzosi, D; Tamponi, U; Mejia guisao, J A; Zepeda fernandez, C H; Szleper, M; Zalewski, P D; Rybka, D K; Gorbunov, I; Perelygin, V; Kozlov, G; Semenov, R; Khvedelidze, A; Kodolova, O; Klyukhin, V; Snigirev, A; Kryukov, A; Ukhanov, M; Sobol, A; Bayshev, I; Akimenko, S; Lei, Y; Chang, Y; Kao, K; Lin, S; Yu, P; Li, Y; Fantasia, C; Gastler, D E; Paus, C; Wyslouch, B; Knuteson, B O; Azzolini, V; Goncharov, M; Brandt, S; Chen, Z; Liu, J; Chen, Z; Freed, S M; Zhang, A; Nachtman, J M; Penzo, A; Akgun, U; Yi, K; Rahmat, R; Gandrajula, R P; Dilsiz, K; Letts, J; Sharma, V A; Holzner, A G; Wuerthwein, F K; Padhi, S; Suarez silva, I M; Tapia takaki, D J; Stringer, R W; Kropivnitskaya, A; Majumder, D; Al-bataineh, A A; Gabella, W E; Johns, W E; Mora, J G; Shi, Z; Ciesielski, R A; Bornheim, A; Bartz, E H; Doroshenko, J; Halkiadakis, E; Salur, S; Robles, J A; Gray, R C; Saka, H; Osherson, M A; Hughes, E J; Paulini, M G; Russ, J S; Jang, D W; Piroue, P; Olsen, J D; Sands, W; Saluja, S; Cutts, D; Hadley, M H; Hakala, J C; Clare, R; Luthra, A P; Paneva, M I; Seto, R K; Mac intire, D A; Tentindo, S; Wahl, H; Chokheli, D; Micanovic, S; Razis, P; Mousa, J; Pantelides, S; Qian, S; Li, W; Stieger, B B; Lee, S W; Michotte de welle, D; De favereau de jeneret, J; Bakhshiansohi, H; Krintiras, G; Caputo, C; Sabev, C; Batinkov, A I; Zenz, S C; Pesaresi, M F; Summers, S P; Saoulidou, N; Koraka, C K; Ghosh, S; Sikdar, A K; Castaldi, R; Dell'orso, R; Palmonari, F; Rolandi, L; Moggi, A; Fedi, G; Coscetti, S; Seo, S H; Cankocak, K; Cumalat, J P; Smith, J G; Iashvili, I; Gallo, S M; Parker, A M; Ledovskoy, A; Hung, P Q; Vaman, D; Goodell, J D; Gomez, J A; Celik, A; Luo, S; Hill, C S; Francis, B P; Tripathi, S M; Squires, M K; Thomson, J A; Brainerd, C; Tuli, S; Bourilkov, D; Mitselmakher, G; Patterson, J R; Kuznetsov, V Y; Tan, S M; Strohman, C R; Rebassoo, F O; Valouev, V; Zelepukin, S; Lusin, S; Vuosalo, C O U; Ruggles, T H; Rusack, R; Woodard, A E; Meng, F; Dev, N; Vishnevskiy, D; Cremaldi, L M; Oliveros tautiva, S J; Jones, T M; Wang, F; Zaganidis, N; Tytgat, M G; Fedorov, A; Korjik, M; Panov, V; Montagna, P; Vitulo, P; Traversi, G; Gonzalez caballero, I; Eysermans, J; Logatchev, O; Orlov, A; Tikhomirov, A; Kulikova, T; Strumia, A; Nam, S K; Soric, I; Padimanskas, M; Siddiqi, H M; Qazi, S F; Ahmad, M; Makouski, M; Chakaberia, I; Mitchell, T B; Baarmand, M; Hits, D; Theofilatos, K; Mohr, N; Jimenez estupinan, R; Micheli, F; Pata, J; Corrodi, S; Mohammadi najafabadi, M; Menasce, D L; Pedrini, D; Malberti, M; Linn, S L; Mesa, D; Tuuva, T; Carrillo montoya, C A; Roque romero, G A; Suwonjandee, N; Kim, H; Khalil ibrahim, S S; Mahrous mohamed kassem, A M; Trojman, L; Sarkar, U; Bhattacharya, S; Babaev, A; Okhotnikov, V; Nakad, Z S; Fruhwirth, R; Majerotto, W; Mikulec, I; Rohringer, H; Strauss, J; Krammer, N; Hartl, C; Pree, E; Rebello teles, P; Ball, A; Bialas, W; Brachet, S B; Gerwig, H; Lourenco, C; Mulders, M P; Vasey, F; Wilhelmsson, M; Dobson, M; Botta, C; Dunser, M F; Pol, A A; Suthakar, U; Takahashi, Y; De cosa, A; Hreus, T; Chen, G; Chen, H; Jiang, C; Yu, T; Klein, K; Schulz, J; Preuten, M; Millet, P N; Keller, H C; Pistone, C; Eckerlin, G; Jung, J; Mnich, J; Jansen, H; Wissing, C; Savitskyi, M; Eichhorn, T V; Harb, A; Botta, V; Martens, I; Knolle, J; Eren, E; Reichelt, O; Schutze, P J; Saibel, A; Schettler, H H; Schumann, S; Kutzner, V G; Husemann, U; Giffels, M; Akbiyik, M; Friese, R M; Baur, S S; Faltermann, N; Kuhn, E; Gottmann, A I D; Muller, D; Balzer, M N; Maier, S; Schnepf, M J; Wassmer, M; Renner, C W; Tcherniakhovski, D; Piedra gomez, J; Vilar cortabitarte, R; Trevisani, N; Boudry, V; Charlot, C P; Tran, T H; Thiant, F; Lethuillier, M M; Perries, S O; Popov, A; Morrissey, Q; Brummitt, A J; Bell, S J; Assiouras, P; Sikler, F; De palma, M; Fiore, L; Pompili, A; Marzocca, C; Errico, F; Soldani, E; Cavallo, F R; Rossi, A M; Torromeo, G; Masetti, G; Virgilio, S; Thyssen, F D M; Iorio, A O M; Montecchi, M; Santanastasio, F; Bulfon, C; Zanetti, A M; Casarsa, M; Han, D; Song, J; Ibrahim, Z A B; Faccioli, P; Gallinaro, M; Beirao da cruz e silva, C; Kuznetsova, E; Levchuk, L; Andreev, V; Toropin, A; Dermenev, A; Karpikov, I; Epshteyn, V; Uliyanov, A; Polikarpov, S; Markin, O; Cagil, A; Karapinar, G; Isildak, B; Yu, S; Banicz, K B; Cheung, H W K; Butler, J N; Quigg, D E; Hufnagel, D; Rakness, G L; Spalding, W J; Bhat, P; Kreis, B J; Jensen, H B; Chetluru, V; Albert, M; Hu, Z; Mishra, K; Vernieri, C; Larson, K E; Zejdl, P; Matulik, M; Cremonesi, M; Doualot, N; Ye, Z; Wu, Z; Geffert, P B; Dutta, V; Heller, R E; Dorsett, A L; Choudhary, B C; Arora, S; Ranjeet, R; Melo da costa, E; Torres da silva de araujo, F; Da silveira, G G; Alves coelho, E; Belchior batista das chagas, E; Buss, N H; Luukka, P R; Tuominen, E M; Havukainen, J J; Tigerstedt, U B S; Goerlach, U; Patois, Y; Collard, C; Mathieu, C; Lowette, S R J; Python, Q P; Moortgat, S; Vanlaer, P; De lentdecker, G W P; Rugovac, S; Tavernier, F F; Beaumont, W; Van de klundert, M; Vankov, P H; Verguilov, V Z; Hadjiiska, R M; De moraes gregores, E; Iope, R L; Ruiz vargas, J C; Barcala riveira, M J; Hernandez calama, J M; Oller, J C; Flix molina, J; Navarro tobar, A; Sastre alvaro, J; Redondo ferrero, D D; Titov, M; Bausson, P; Major, P; Bala, S; Dhingra, N; Kumari, P; Costa, S; Pelli, S; Meneguzzo, A T; Passaseo, M; Pegoraro, M; Montecassiano, F; Dorigo, T; Silvestrin, L; Del duca, V; Demaria, N; Ferrero, M I; Mussa, R; Cartiglia, N; Mazza, G; Maina, E; Dellacasa, G; Covarelli, R; Cotto, G; Sola, V; Monteil, E; Shchelina, K; Castilla-valdez, H; De la cruz burelo, E; Kazana, M; Gorbunov, N; Kosarev, I; Smirnov, V; Korenkov, V; Savina, M; Lanev, A; Semenyushkin, I; Kashunin, I; Krouglov, N; Markina, A; Bunichev, V; Zotov, N; Miagkov, I; Nazarova, E; Uzunyan, A; Riutin, R; Tsverava, N; Paganis, E; Chen, K; Lu, R; Psallidas, A; Gorodetzky, P P; Hazen, E S; Avetisyan, A; Richardson, C A; Busza, W; Roland, C E; Cali, I A; Marini, A C; Wang, T; Schmitt, M H; Geurts, F; Ecklund, K M; Repond, J O; Schmidt, I; George, N; Ingram, F D; Wetzel, J W; Ogul, H; Spanier, S M; Mrak tadel, A; Zevi della porta, G J; Maguire, C F; Janjam, R K; Chevtchenko, S; Zhu, R; Voicu, B R; Mao, J; Stone, R L; Schnetzer, S R; Nash, K C; Kunnawalkam elayavalli, R; Laflotte, I; Weinberg, M G; Mc cracken, M E; Kalogeropoulos, A; Raval, A H; Cooperstein, S B; Landsberg, G; Kwok, K H M; Ellison, J A; Gary, J W; Si, W; Hagopian, V; Hagopian, S L; Bertoldi, M; Brigljevic, V; Ptochos, F; Ather, M W; Konstantinou, S; Yang, D; Li, Q; Attebury, G; Siado castaneda, J E; Lemaitre, V; Caebergs, T P M; Litov, L B; Fernandez de troconiz, J; Colling, D J; Davies, G J; Raymond, D M; Virdee, T S; Bainbridge, R J; Lewis, P; Rose, A W; Bauer, D U; Sotiropoulos, S; Papadopoulos, I; Triantis, F; Aslanoglou, X; Majumdar, N; Devadula, S; Ciocci, M A; Messineo, A; Palla, F; Grippo, M T; Yu, G B; Willemse, T; Lamsa, J; Blumenfeld, B J; Maksimovic, P; Gritsan, A; Cocoros, A A; Arnold, P; Tonwar, S C; Eno, S C; Mignerey, A L C; Nabili, S; Dalchenko, M; Maghrbi, Y; Huang, T; Sheharyar, A; Durkin, L S; Wang, Z; Tos, K M; Kim, B J; Guo, Y; Ma, P; Rosenzweig, D J; Reeder, D D; Smith, W; Surkov, A; Mohapatra, A K; Maurisset, A; Mans, J M; Kubota, Y; Frahm, E J; Chatterjee, R M; Ruchti, R; Mc cauley, T P; Ivie, P A; Betchart, B A; Hindrichs, O H; Sultana, M; Henderson, C; Sanders, D; Summers, D; Perera, L; Miller, D H; Miyamoto, J; Peng, C; Zahariev, R Z; Peynekov, M M; Ratti, L; Ressegotti, M; Czellar, S; Molnar, J; Khan, A; Morton, A; Vischia, P; Erice cid, C F; Carpinteyro bernardino, S; Chmelev, D; Smetannikov, V; Hektor, A; Kadastik, M; Godinovic, N; Simelevicius, D; Alvi, O I; Hoorani, H U R; Shahzad, H; Shah, M A; Shoaib, M; Rao, M A S; Sidwell, R; Roettger, T J; Corkill, S; Lustermann, W; Roeser, U H; Backhaus, M; Perrin, G L; Naseri, M; Rapuano, F; Redaelli, N; Carbone, L; Spiga, F; Brivio, F; Monti, F; Markowitz, P E; Rodriguez, J L; Morelos pineda, A; Norberg, S R; Ryu, M S; Jeng, Y G; Esteban lallana, M C; Trabelsi, A; Dittmann, J R; Elsayed, E; Khan, Z A; Soomro, K; Janikashvili, M; Kapoor, A; Rastogi, A; Remnev, G; Hrubec, J; Wulz, C; Fichtinger, S K; Abbaneo, D; Janot, P; Racz, A; Roche, J; Ryjov, V; Sphicas, P; Treille, D; Wertelaers, P; Cure, B R; Fulcher, J R; Moortgat, F W; Bocci, A; Giordano, D; Hegeman, J G; Hegner, B; Gallrapp, C; Cepeda hermida, M L; Riahi, H; Chapon, E; Orfanelli, S; Guilbaud, M R J; Seidel, M; Merlin, J A; Heidegger, C; Schneider, M A; Robmann, P W; Salerno, D N; Galloni, C; Neutelings, I W; Shi, J; Li, J; Zhao, J; Pandoulas, D; Rauch, M P; Schael, S; Hoepfner, K; Weber, M K; Teyssier, D F; Thuer, S; Rieger, M; Albert, A; Muller, T; Sert, H; Lohmann, W F; Ntomari, E; Grohsjean, A J; Wen, Y; Ron alvarez, E; Hampe, J; Bin anuar, A A; Blobel, V; Mattig, S; Haller, J; Sonneveld, J M; Malara, A; Rabbertz, K H; Freund, B; Schell, D B; Savoiu, D; Geerebaert, Y; Becheva, E L; Nguyen, M A; Stahl leiton, A G; Magniette, F B; Fay, J; Gascon-shotkin, S M; Ille, B; Viret, S; Finco, L; Brown, R; Cockerill, D; Williams, T S; Markou, C; Anagnostou, G; Mohanty, A K; Creanza, D M; De robertis, G; Verwilligen, P O J; Perrotta, A; Fanfani, A; Ciocca, C; Ravera, F; Toniolo, N; Badoer, S; Paolucci, P; Khan, W A; Voevodina, E; De iorio, A; Cavallari, F; Bellini, F; Cossutti, F; La licata, C; Da rold, A; Lee, K; Go, Y; Park, J; Kim, M S; Wan abdullah, W; Toldaiev, O; Golovtcov, V; Oreshkin, V; Sosnov, D; Soroka, D; Gninenko, S; Pivovarov, G; Erofeeva, M; Pozdnyakov, I; Danilov, M; Tarkovskii, E; Chadeeva, M; Philippov, D; Bychkova, O; Kardapoltsev, L; Onengut, G; Cerci, S; Vergili, M; Dolek, F; Sever, R; Gamsizkan, H; Ocalan, K; Dogan, H; Kaya, M; Kuo, C; Chang, Y; Albrow, M G; Banerjee, S; Berryhill, J W; Chevenier, G; Freeman, J E; Green, C H; O'dell, V R; Wenzel, H; Lukhanin, G; Di luca, S; Spiegel, L G; Deptuch, G W; Ratnikova, N; Paterno, M F; Burkett, K A; Jones, C D; Klima, B; Fagan, D; Hasegawa, S; Thompson, R; Gecse, Z; Liu, M; Pedro, K J; Jindariani, S; Zimmerman, T; Skirvin, T M; Hofman, D J; Evdokimov, O; Jung, K E; Trauger, H C; Gouskos, L; Karancsi, J; Kumar, A; Garg, R B; Keshri, S; Nogima, H; Sznajder, A; Vilela pereira, A; Eerola, P A; Pekkanen, J T K; Guldmyr, J H; Gele, D; Charles, L; Bonnin, C; Bourgatte, G; De clercq, J T; Favart, L; Grebenyuk, A; Yang, Y; Allard, Y; Genchev, V I; Galli mercadante, P; Tomei fernandez, T R; Ahuja, S; Ingram, Q; Rohe, T V; Colino, N; Ferrando, A; Garcia-abia, P; Calvo alamillo, E; Goy lopez, S; Delgado peris, A; Alvarez fernandez, A; Couderc, F; Moudden, Y; Potenza, R; D'alessandro, R; Landi, G; Viliani, L; Bisello, D; Gasparini, F; Michelotto, M; Benettoni, M; Bellato, M A; Fanzago, F; De castro manzano, P; Mantovani, G; Menichelli, M; Passeri, D; Placidi, P; Manoni, E; Storchi, L; Cirio, R; Romero, A; Staiano, A; Pastrone, N; Solano, A M; Argiro, S; Bellan, R; Duran osuna, M C; Ershov, Y; Zamyatin, N; Palchik, V; Afanasyev, S; Nikonov, E; Miller, M; Baranov, A; Ivanov, V; Petrushanko, S; Perfilov, M; Eyyubova, G; Baskakov, A; Kachanov, V; Korablev, A; Bordanovskiy, A; Kepuladze, Z; Hsiung, Y B; Wu, S; Rankin, D S; Jacob, C J; Alverson, G; Hortiangtham, A; Roland, G M; Gomez ceballos retuerto, G; Innocenti, G M; Allen, B L; Baty, A A; Narayanan, S M; Hu, M; Bi, R; Sung, K K H; Gunter, T K; Bueghly, J D; Yepes stork, P P; Mestvirishvili, A; Miller, M J; Norbeck, J E; Snyder, C M; Branson, J G; Sfiligoi, I; Rogan, C S; Edwards-bruner, C R; Young, R W; Verweij, M; Goulianos, K; Galvez, P D; Zhu, K; Lapadatescu, V; Dutta, I; Somalwar, S V; Park, M; Kaplan, S M; Feld, D B; Vorobiev, I; Lange, D; Zuranski, A M; Mei, K; Knight iii, R R; Spencer, E; Hogan, J M; Syarif, R; Olmedo negrete, M A; Ghiasi shirazi, S; Erodotou, E; Ban, Y; Xue, Z; Kravchenko, I; Keller, J D; Knowlton, D P; Wigmans, M E J; Volobouev, I; Peltola, T H T; Kovac, M; Bruno, G L; Gregoire, G; Delaere, C; Bodlak, M; Della negra, M J; James, T O; Shtipliyski, A M; Tziaferi, E; Karageorgos, V W; Karasavvas, D; Fountas, K; Mukhopadhyay, S; Basti, A; Raffaelli, F; Spandre, G; Mazzoni, E; Manca, E; Mandorli, G; Yoo, H D; Aerts, A; Eminizer, N C; Amram, O; Stenson, K M; Ford, W T; Green, M L; Kellogg, R; Jeng, G; Kunkle, J M; Baron, O; Feng, Y; Wong, K; Toufique, Y; Sehgal, V; Breedon, R E; Cox, P T; Mulhearn, M J; Gerhard, R M; Taylor, D N; Konigsberg, J; Sperka, D M; Lo, K H; Carnes, A M; Quach, D M; Li, T; Andreev, V; Herve, L A M; Klabbers, P R; Svetek, A; Hussain, U; Evans, A C; Lannon, K P; Fedorov, S; Bodek, A; Demina, R; Khukhunaishvili, A; West, C A; Perez, C U; Godang, R; Meier, M; Neumeister, N; Gruchala, M M; Zagurski, K B; Prosolovich, V; Kuhn, J; Ratti, S P; Riccardi, C M; Vacchi, C; Szekely, G; Hobson, P R; Fernandez menendez, J; Rodriguez bouza, V; Butler, P; Pedraza morales, M I; Barakat, N; Sakharov, V; Lavrenov, P; Ahmed, I; Kim, T Y; Pac, M Y; Sculac, T; Gajdosik, T; Tamosiunas, K; Juodagalvis, A; Dudenas, V; Barannik, S; Bashir, A; Khan, F; Saeed, F; Khan, M T; Maravin, Y; Mohammadi, A; Noonan, D C; Saunders, M D; Dittmar, M; Donega, M; Perrozzi, L; Nageli, C; Dorfer, C; Zhu, D H; Spirig, Y A; Ruini, D; Alishahiha, M; Ardalan, F; Saramad, S; Mansouri, R; Eskandari tadavani, E; Ragazzi, S; Tabarelli de fatis, T; Govoni, P; Ghezzi, A; Stringhini, G; Sevilla moreno, A C; Smith, C J; Abdelalim, A A; Hassan, A F A; Swain, S K; Sahoo, D K; Carrera jarrin, E F; Chauhan, S; Munoz chavero, F; Ambrogi, F; Hensel, C; Alves, G A; Baechler, J; Christiansen, J; De roeck, A; Gayde, J; Hansen, M; Kienzle, W; Reynaud, S; Schwick, C; Troska, J; Zeuner, W D; Osborne, J A; Moll, M; Franzoni, G; Tinoco mendes, A D; Milenovic, P; Garai, Z; Bendavid, J L; Dupont, N A; Gulhan, D C; Daponte, V; Martinez turtos, R; Giuffredi, R; Rapacz, K J; Otiougova, P; Zhu, G; Leggat, D A; Kiesel, M K; Lipinski, M; Wallraff, W; Meyer, A; Pook, T; Pooth, O; Behnke, O; Eckstein, D; Fischer, D J; Garay garcia, J; Vagnerini, A; Klanner, R; Stadie, H; Perieanu, A; Benecke, A; Abbas, S M; Schroeder, M; Lobelle pardo, P; Chwalek, T; Heidecker, C; Floh, K M; Gomez, G; Cabrillo bartolome, I J; Orviz fernandez, P; Duarte campderros, J; Busson, P; Dobrzynski, L; Fontaine, G R R; Granier de cassagnac, R; Paganini, P R J; Arleo, F P; Balagura, V; Martin blanco, J; Ortona, G; Kucher, I; Contardo, D C; Lumb, N; Baulieu, G; Lagarde, F; Shchablo, K; Heath, H F; Kreczko, L; Clement, E J; Paramesvaran, S; Bologna, S; Bell, K W; Petyt, D A; Moretti, S; Durkin, T J; Daskalakis, G; Kataria, S K; Iaselli, G; Pugliese, G; My, S; Sharma, A; Abbiendi, G; Taneja, S; Benussi, L; Fabbri, F; Calvelli, V; Frizziero, E; Barone, L M; De notaristefani, F; D'imperio, G; Gobbo, B; Yusupov, H; Liew, C S; Zabolotny, W M; Sobolev, S; Gavrikov, Y; Kozlov, I; Golubev, N; Andreev, Y; Tlisov, D; Zaytsev, V; Stepennov, A; Popova, E; Kolchanova, A; Shtol, D; Sirunyan, A; Gokbulut, G; Kara, O; Damarseckin, S; Guler, A M; Ozpineci, A; Hayreter, A; Li, S; Gruenendahl, S; Yarba, J; Para, A; Ristori, L F; Rubinov, P M; Reichanadter, M A; Churin, I; Beretvas, A; Muzaffar, S M; Lykken, J D; Gutsche, O; Baldin, B; Uplegger, L A; Lei, C M; Wu, W; Derylo, G E; Ruschman, M K; Lipton, R J; Whitbeck, A J; Schmitt, R; Contreras pasuy, L C; Olsen, J T; Cavanaugh, R J; Betts, R R; Wang, H; Sturdy, J T; Gutierrez jr, A; Campagnari, C F; White, D T; Brewer, F D; Qu, H; Ranjan, K; Lalwani, K; Md, H; Shah, A H; Fonseca de souza, S; De jesus damiao, D; Revoredo, E A; Chinellato, J A; Amadei marques da costa, C; Lampen, P T; Wendland, L A; Brom, J; Andrea, J; Tavernier, S; Van doninck, W K; Van mulders, P K A; Clerbaux, B; Rougny, R; Rashevski, G D; Rodozov, M N; Padula, S; Bernardes, C A; Dias maciel, C; Deiters, K; Feichtinger, D; Wiederkehr, S A; Cerrada, M; Fouz iglesias, M; Senghi soares, M; Pasquetto, E; Ferry, S C; Georgette, Z; Malcles, J; Csanad, M; Lal, M K; Walia, G; Kaur, A; Ciulli, V; Lenzi, P; Zanetti, M; Costa, M; Dughera, G; Bartosik, N; Ramirez sanchez, G; Frueboes, T M; Karjavine, V; Skachkov, N; Litvinenko, A; Petrosyan, A; Teryaev, O; Trofimov, V; Makankin, A; Golunov, A; Savrin, V; Korotkikh, V; Vardanyan, I; Lukina, O; Belyaev, A; Korneeva, N; Petukhov, V; Skvortsov, V; Konstantinov, D; Efremov, V; Smirnov, N; Shiu, J; Chen, P; Rohlf, J; Sulak, L R; St john, J M; Morse, D M; Krajczar, K F; Mironov, C M; Niu, X; Wang, J; Charaf, O; Matveev, M; Eppley, G W; Mccliment, E R; Ozok, F; Bilki, B; Zieser, A J; Olivito, D J; Wood, J G; Hashemi, B T; Bean, A L; Wang, Q; Tuo, S; Xu, Q; Roberts, J W; Anderson, D J; Lath, A; Jacques, P; Sun, M; Andrews, M B; Svyatkovskiy, A; Hardenbrook, J R; Heintz, U; Lee, J; Wang, L; Prosper, H B; Adams, J R; Liu, S; Wang, D; Swanson, D; Thiltges, J F; Undleeb, S; Finger, M; Beuselinck, R; Rand, D T; Tapper, A D; Malik, S A; Lane, R C; Panagiotou, A; Diamantopoulou, M; Vourliotis, E; Mallios, S; Mondal, K; Bhattacharya, R; Bhowmik, D; Libby, J F; Azzurri, P; Foa, L; Tenchini, R; Verdini, P G; Ciampa, A; Radburn-smith, B C; Park, J; Swartz, M L; Sarica, U; Borcherding, F O; Barria, P; Goadhouse, S D; Xia, F; Joyce, M L; Belloni, A; Bouhali, O; Toback, D; Osipenkov, I L; Almes, G T; Walker, J W; Bylsma, B G; Lefeld, A J; Conway, J S; Flores, C S; Avery, P R; Terentyev, N; Barashko, V; Ryd, A P E; Tucker, J M; Heltsley, B K; Wittich, P; Riley, D S; Skinnari, L A; Chu, J Y; Ignatenko, M; Lindgren, M A; Saltzberg, D P; Peck, A N; Herve, A A M; Savin, A; Herndon, M F; Mason, W P; Martirosyan, S; Grahl, J; Hansen, P D; Saradhy, R; Mueller, C N; Planer, M D; Suh, I S; Hurtado anampa, K P; De barbaro, P J; Garcia-bellido alvarez de miranda, A A; Korjenevski, S K; Moolekamp, F E; Fallon, C T; Acosta castillo, J G; Gutay, L; Barker, A W; Gough, E; Poyraz, D; Verbeke, W L M; Beniozef, I S; Krasteva, R L; Winn, D R; Fenyvesi, A C; Makovec, A; Munro, C G; Sanchez cruz, S; Bernardino rodrigues, N A; Lokhovitskiy, A; Uribe estrada, C; Rebane, L; Racioppi, A; Kim, H; Kim, T; Puljak, I; Boyaryntsev, A; Saeed, M; Tanwir, S; Butt, U; Hussain, A; Nawaz, A; Khurshid, T; Imran, M; Sultan, A; Naeem, M; Kaadze, K; Modak, A; Taylor, R D; Kim, D; Grab, C; Nessi-tedaldi, F; Fischer, J; Manzoni, R A; Zagozdzinska-bochenek, A A; Berger, P; Reichmann, M P; Hashemi, M; Rezaei hosseinabadi, F; Paganoni, M; Farina, F M; Joshi, Y R; Avila bernal, C A; Cabrera mora, A L; Segura delgado, M A; Gonzalez hernandez, C F; Asavapibhop, B; U-ruekolan, S; Kim, G; Choi, M; Aly, S; El sawy, M; Castaneda hernandez, A M; Pinna, D; Shamdasani, J; Tavkhelidze, D; Hegde, V; Aziz, T; Sur, N; Sutar, B J; Karmakar, S; Ghete, V M; Dragicevic, M G; Brandstetter, J; Marques moraes, A; Molina insfran, J A; Aspell, P; Baillon, P; Barney, D; Honma, A; Pape, L; Sakulin, H; Macpherson, A L; Bangert, N; Guida, R; Steggemann, J; Voutsinas, G G; Da silva gomes, D; Ben mimoun bel hadj, F; Bonnaud, J Y R; Canelli, F M; Bai, J; Qiu, J; Bian, J; Cheng, Y; Kukulies, C; Teroerde, M; Erdmann, M; Hebbeker, T; Zantis, F; Scheuch, F; Erdogan, Y; Campbell, A J; Kasemann, M; Lange, W; Raspiareza, A; Melzer-pellmann, I; Aldaya martin, M; Lewendel, B; Schmidt, R S; Lipka, E; Missiroli, M; Grados luyando, J M; Shevchenko, R; Babounikau, I; Steinbrueck, G; Vanhoefer, A; Ebrahimi, A; Pena rodriguez, K J; Niedziela, M A; Eich, M M; Froehlich, A; Simonis, H J; Katkov, I; Wozniewski, S; Marco de lucas, R J; Lopez virto, A M; Jaramillo echeverria, R W; Hennion, P; Zghiche, A; Chiron, A; Romanteau, T; Beaudette, F; Lobanov, A; Grasseau, G J; Pierre-emile, T B; El mamouni, H; Gouzevitch, M; Goldstein, J; Cussans, D G; Seif el nasr, S A; Titterton, A S; Ford, P J W; Olaiya, E O; Salisbury, J G; Paspalaki, G; Asenov, P; Hidas, P; Kiss, T N; Zalan, P; Shukla, P; Abbrescia, M; De filippis, N; Donvito, G; Radogna, R; Miniello, G; Gelmi, A; Capiluppi, P; Marcellini, S; Odorici, F; Bonacorsi, D; Genta, C; Ferri, G; Saviano, G; Ferrini, M; Minutoli, S; Tosi, S; Lista, L; Passeggio, G; Breglio, G; Merola, M; Diemoz, M; Rahatlou, S; Baccaro, S; Bartoloni, A; Talamo, I G; Cipriani, M; Kim, J Y; Oh, G; Lim, J H; Lee, J; Mohamad idris, F B; Gani, A B; Cwiok, M; Doroba, K; Martins galinhas, B E; Kim, V; Krivshich, A; Vorobyev, A; Ivanov, Y; Tarakanov, V; Lobodenko, A; Obikhod, T; Isayev, O; Kurov, O; Leonidov, A; Lvova, N; Kirsanov, M; Suvorova, O; Karneyeu, A; Demidov, S; Konoplyannikov, A; Popov, V; Pakhlov, P; Vinogradov, S; Klemin, S; Blinov, V; Skovpen, I; Chatrchyan, S; Grigorian, N; Kayis topaksu, A; Sunar cerci, D; Hos, I; Guler, Y; Kiminsu, U; Serin, M; Deniz, M; Turan, I; Eryol, F; Pozdnyakov, A; Liu, Z; Doan, T H; Hanlon, J E; Mcbride, P L; Pal, I; Garren, L; Oleynik, G; Harris, R M; Bolla, G; Kowalkowski, J B; Evans, D E; Vaandering, E W; Patrick, J F; Rechenmacher, R; Prosser, A G; Messer, T A; Tiradani, A R; Rivera, R A; Jayatilaka, B A; Duarte, J M; Todri, A; Harr, R F; Richman, J D; Bhandari, R; Dordevic, M; Cirkovic, P; Mora herrera, C; Rosa lopes zachi, A; De paula carvalho, W; Kinnunen, R L A; Lehti, S T; Maeenpaeae, T H; Bloch, D; Chabert, E C; Rudolf, N G; Devroede, O; Skovpen, K; Lontkovskyi, D; De wolf, E A; Van mechelen, P; Van spilbeeck, A B E; Georgiev, L S; Novaes, S F; Costa, M A; Costa leal, B; Horisberger, R P; De la cruz, B; Willmott, C; Perez-calero yzquierdo, A M; Dejardin, M M; Mehta, A; Barbagli, G; Focardi, E; Bacchetta, N; Gasparini, U; Pantano, D; Sgaravatto, M; Ventura, S; Zotto, P; Candelori, A; Pozzobon, N; Boletti, A; Servoli, L; Postolache, V; Rossi, A; Ciangottini, D; Alunni solestizi, L; Maselli, S; Migliore, E; Amapane, N C; Lopez fernandez, R; Sanchez hernandez, A; Heredia de la cruz, I; Matveev, V; Kracikova, T; Shmatov, S; Vasilev, S; Kurenkov, A; Oleynik, D; Verkheev, A; Voytishin, N; Proskuryakov, A; Bogdanova, G; Petrova, E; Bagaturia, I; Tsamalaidze, Z; Zhao, Z; Arcaro, D J; Barberis, E; Wamorkar, T; Wang, B; Ralph, D K; Velasco, M M; Odell, N J; Sevova, S; Li, W; Merlo, J; Onel, Y; Mermerkaya, H; Moeller, A R; Haytmyradov, M; Dong, R; Bugg, W M; Ragghianti, G C; Delannoy sotomayor, A G; Thapa, K; Yagil, A; Gerosa, R A; Masciovecchio, M; Schmitz, E J; Kapustinsky, J S; Greene, S V; Zhang, L; Vlimant, J V; Mughal, A; Cury siqueira, S; Gershtein, Y; Arora, S R R; Lin, W X; Stickland, D P; Mc donald, K T; Pivarski, J M C; Lucchini, M T; Higginbotham, S L; Rosenfield, M; Long, O R; Johnson, K F; Adams, T; Susa, T; Rykaczewski, H; Ioannou, A; Ge, Y; Levin, A M; Li, J; Li, L; Bloom, K A; Monroy montanez, J A; Kunori, S; Wang, Z; Favart, D; Maltoni, F; Vidal marono, M; Delcourt, M; Markov, S I; Seez, C; Richards, A J; Ferguson, W; Chatziangelou, M; Karathanasis, G; Kontaxakis, P; Jones, J A; Strologas, J; Katsoulis, P; Dutt, S; Roy chowdhury, S; Bhardwaj, R; Purohit, A; Singh, B; Behera, P K; Sharma, A; Spagnolo, P; Tonelli, G E; Giannini, L; Poulios, S; Groote, J F; Untuc, B; Oztirpan, F O; Koseoglu, I; Luiggi lopez, E E; Hadley, N J; Shin, Y H; Safonov, A; Eusebi, R; Rose, A K; Overton, D A; Erbacher, R D; Funk, G N; Pilot, J R; Regnery, B J; Klimenko, S; Matchev, K; Gleyzer, S; Wang, J; Cadamuro, L; Sun, W M; Soffi, L; Lantz, S R; Wright, D; Cline, D; Cousins jr, R D; Erhan, S; Yang, X; Schnaible, C J; Dasgupta, A; Loveless, R; Bradley, D C; Monzat, D; Dodd, L M; Tikalsky, J L; Kapusta, J; Gilbert, W J; Lesko, Z J; Marinelli, N; Wayne, M R; Heering, A H; Galanti, M; Duh, Y; Roy, A; Arabgol, M; Hacker, T J; Salva, S; Petrov, V; Barychevski, V; Drobychev, G; Lobko, A; Gabusi, M; Fabris, L; Conte, E R E; Kasprowicz, G H; Kyberd, P; Cole, J E; Lopez, J M; Salazar gonzalez, C A; Benzon, A M; Pelagio, L; Walsh, M F; Postnov, A; Lelas, D; Vaitkus, J V; Jurciukonis, D; Sulmanas, B; Ahmad, A; Ahmed, W; Jalil, S H; Kahl, W E; Taylor, D R; Choi, Y I; Jeong, Y; Roy, T; Schoenenberger, M A; Khateri, P; Etesami, S M; Fiorini, E; Pullia, A; Magni, S; Gennai, S; Fiorendi, S; Zuolo, D; Sanabria arenas, J C; Florez bustos, C A; Holguin coral, A; Mendez, H; Srimanobhas, N; Jaikar, A H; Arteche gonzalez, F J; Call, K R; Vazquez valencia, E F; Calderon monroy, M A; Abdelmaguid, A; Mal, P K; Yuan, L; Lomidze, I; Prangishvili, I; Adamov, G; Dube, S S; Dugad, S; Mohanty, G B; Bhat, M A; Bheesette, S; Malawski, M L; Abou kors, D J

    CMS is a general purpose proton-proton detector designed to run at the highest luminosity at the LHC. It is also well adapted for studies at the initially lower luminosities. The CMS Collaboration consists of over 1800 scientists and engineers from 151 institutes in 31 countries. The main design goals of CMS are: \\begin{enumerate} \\item a highly performant muon system, \\item the best possible electromagnetic calorimeter \\item high quality central tracking \\item hermetic calorimetry \\item a detector costing less than 475 MCHF. \\end{enumerate} All detector sub-systems have started construction. Engineering Design Reviews of parts of these sub-systems have been successfully carried-out. These are held prior to granting authorization for purchase. The schedule for the LHC machine and the experiments has been revised and CMS will be ready for first collisions now expected in April 2006. \\\\\\\\ ~~~~$\\bullet$ Magnet \\\\ The detector (see Figure) will be built around a long (13~m) and large bore ($\\phi$=5.9~m) high...

  14. Position readout by charge division in large two-dimensional detectors

    International Nuclear Information System (INIS)

    Alberi, J.L.

    1976-10-01

    The improvement in readout spatial resolution for charge division systems with subdivided readout electrodes has been analyzed. This readout forms the position and sum signals by a linear, unambiguous analogue summation technique. It is shown that the readout resolution is a function of only electrode capacitance and shaping parameters. The line width improves as 1/N/sup 1 / 2 /, where N is the number of electrode subdivisions

  15. The CMS conductor

    CERN Document Server

    Horváth, I L; Marti, H P; Neuenschwander, J; Smith, R P; Fabbricatore, P; Musenich, R; Calvo, A; Campi, D; Curé, B; Desirelli, Alberto; Favre, G; Riboni, P L; Sgobba, Stefano; Tardy, T; Sequeira-Lopes-Tavares, S

    2000-01-01

    The Compact Muon Solenoid (CMS) is one of the experiments, which are being designed in the framework of the Large Hadron Collider (LHC) project at CERN, the design field of the CMS magnet is 4 T, the magnetic length is 13 m and the aperture is 6 m. This high magnetic field is achieved by means of a 4 layer, 5 modules superconducting coil. The coil is wound from an Al-stabilized Rutherford type conductor. The nominal current of the magnet is 20 kA at 4.5 K. In the CMS coil the structural function is ensured, unlike in other existing Al-stabilized thin solenoids, both by the Al-alloy reinforced conductor and the external former. In this paper the retained manufacturing process of the 50-km long reinforced conductor is described. In general the Rutherford type cable is surrounded by high purity aluminium in a continuous co-extrusion process to produce the Insert. Thereafter the reinforcement is joined by Electron Beam Welding to the pure Al of the insert, before being machined to the final dimensions. During the...

  16. The readout system of the new H1 silicon detectors

    International Nuclear Information System (INIS)

    Buerger, J.; Hansen, K.; Lange, W.; Prell, S.; Zimmermann, W.; Henschel, H.; Haynes, W.J.; Noyes, G.W.; Joensson, L.; Gabathuler, K.; Horisberger, R.; Wagener, M.; Eichler, R.; Erdmann, W.; Niggli, H.; Pitzl, D.

    1995-03-01

    The H1 detector at HERA at DESY undergoes presently a major upgrade. In this context silicon strip detectors have been installed at beginning of 1995. The high bunch crossing frequency of HERA (10.4 MHz) demands a novel readout architecture which includes pipelining, signal processing and data reduction at a very early stage. The front end readout is hierarchically organized. The detector elements are read out by the APC chip which contains an analog pipeline and performs first background subtraction. Up to five readout chips are controlled by a Decoder Chip. The readout processor module (OnSiRoC) operates the detectors, controls the Decoder Chips and performs a first level data reduction. The paper describes the readout architecture of the H1 Silicon Detectors and performance data of the complete readout chain. (orig.)

  17. The CMS Higgs Boson Goose Game

    CERN Document Server

    Cavallo, Francesca Romana

    2015-01-01

    Building and operating the CMS Detector is a complicated endeavour! Now, more than 20 years after the detector was conceived, the CMS Bologna group proposes to follow the steps of this challenging project by playing The Higgs Boson Goose Game, illustrating CMS activities and goals.The concept of the game is inspired by the traditional Game of the Goose. The underlying idea is that the progress of building and operating a detector at the LHC is similar to the progress of the pawns on the game board it is fast at times, bringing rewards and satisfaction, while sometimes unexpected problems cause delays or even a step back requiring CMS scientists to use all of their skill and creativity to devise new solutions.

  18. CMS distributed computing workflow experience

    Science.gov (United States)

    Adelman-McCarthy, Jennifer; Gutsche, Oliver; Haas, Jeffrey D.; Prosper, Harrison B.; Dutta, Valentina; Gomez-Ceballos, Guillelmo; Hahn, Kristian; Klute, Markus; Mohapatra, Ajit; Spinoso, Vincenzo; Kcira, Dorian; Caudron, Julien; Liao, Junhui; Pin, Arnaud; Schul, Nicolas; De Lentdecker, Gilles; McCartin, Joseph; Vanelderen, Lukas; Janssen, Xavier; Tsyganov, Andrey; Barge, Derek; Lahiff, Andrew

    2011-12-01

    The vast majority of the CMS Computing capacity, which is organized in a tiered hierarchy, is located away from CERN. The 7 Tier-1 sites archive the LHC proton-proton collision data that is initially processed at CERN. These sites provide access to all recorded and simulated data for the Tier-2 sites, via wide-area network (WAN) transfers. All central data processing workflows are executed at the Tier-1 level, which contain re-reconstruction and skimming workflows of collision data as well as reprocessing of simulated data to adapt to changing detector conditions. This paper describes the operation of the CMS processing infrastructure at the Tier-1 level. The Tier-1 workflows are described in detail. The operational optimization of resource usage is described. In particular, the variation of different workflows during the data taking period of 2010, their efficiencies and latencies as well as their impact on the delivery of physics results is discussed and lessons are drawn from this experience. The simulation of proton-proton collisions for the CMS experiment is primarily carried out at the second tier of the CMS computing infrastructure. Half of the Tier-2 sites of CMS are reserved for central Monte Carlo (MC) production while the other half is available for user analysis. This paper summarizes the large throughput of the MC production operation during the data taking period of 2010 and discusses the latencies and efficiencies of the various types of MC production workflows. We present the operational procedures to optimize the usage of available resources and we the operational model of CMS for including opportunistic resources, such as the larger Tier-3 sites, into the central production operation.

  19. CMS distributed computing workflow experience

    International Nuclear Information System (INIS)

    Adelman-McCarthy, Jennifer; Gutsche, Oliver; Haas, Jeffrey D; Prosper, Harrison B; Dutta, Valentina; Gomez-Ceballos, Guillelmo; Hahn, Kristian; Klute, Markus; Mohapatra, Ajit; Spinoso, Vincenzo; Kcira, Dorian; Caudron, Julien; Liao Junhui; Pin, Arnaud; Schul, Nicolas; Lentdecker, Gilles De; McCartin, Joseph; Vanelderen, Lukas; Janssen, Xavier; Tsyganov, Andrey

    2011-01-01

    The vast majority of the CMS Computing capacity, which is organized in a tiered hierarchy, is located away from CERN. The 7 Tier-1 sites archive the LHC proton-proton collision data that is initially processed at CERN. These sites provide access to all recorded and simulated data for the Tier-2 sites, via wide-area network (WAN) transfers. All central data processing workflows are executed at the Tier-1 level, which contain re-reconstruction and skimming workflows of collision data as well as reprocessing of simulated data to adapt to changing detector conditions. This paper describes the operation of the CMS processing infrastructure at the Tier-1 level. The Tier-1 workflows are described in detail. The operational optimization of resource usage is described. In particular, the variation of different workflows during the data taking period of 2010, their efficiencies and latencies as well as their impact on the delivery of physics results is discussed and lessons are drawn from this experience. The simulation of proton-proton collisions for the CMS experiment is primarily carried out at the second tier of the CMS computing infrastructure. Half of the Tier-2 sites of CMS are reserved for central Monte Carlo (MC) production while the other half is available for user analysis. This paper summarizes the large throughput of the MC production operation during the data taking period of 2010 and discusses the latencies and efficiencies of the various types of MC production workflows. We present the operational procedures to optimize the usage of available resources and we the operational model of CMS for including opportunistic resources, such as the larger Tier-3 sites, into the central production operation.

  20. Hybrid amplifier for calorimetry with photodiode readout

    Energy Technology Data Exchange (ETDEWEB)

    Sushkov, V V

    1994-12-31

    A hybrid surface mounted amplifier for the photodiode readout of the EM calorimeter has been developed. The main technical characteristics of the design are presented. The design able to math readout constraints for a high luminosity collider experiment is discussed. 10 refs., 2 tabs., 8 figs.

  1. Validation of software releases for CMS

    International Nuclear Information System (INIS)

    Gutsche, Oliver

    2010-01-01

    The CMS software stack currently consists of more than 2 Million lines of code developed by over 250 authors with a new version being released every week. CMS has setup a validation process for quality assurance which enables the developers to compare the performance of a release to previous releases and references. The validation process provides the developers with reconstructed datasets of real data and MC samples. The samples span the whole range of detector effects and important physics signatures to benchmark the performance of the software. They are used to investigate interdependency effects of all CMS software components and to find and fix bugs. The release validation process described here is an integral part of CMS software development and contributes significantly to ensure stable production and analysis. It represents a sizable contribution to the overall MC production of CMS. Its success emphasizes the importance of a streamlined release validation process for projects with a large code basis and significant number of developers and can function as a model for future projects.

  2. 42 CFR 438.724 - Notice to CMS.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Notice to CMS. 438.724 Section 438.724 Public...) MEDICAL ASSISTANCE PROGRAMS MANAGED CARE Sanctions § 438.724 Notice to CMS. (a) The State must give the CMS Regional Office written notice whenever it imposes or lifts a sanction for one of the violations...

  3. Development and Evaluation of a Test System for the Quality Assurance during the Mass Production of Silicon Microstrip Detector Modules for the CMS Experiment

    CERN Document Server

    Franke, Torsten

    2005-01-01

    The Compact Muon Solenoid (CMS) is one of four large-scale experiments that is going to be installed at the Large Hadron Collider (LHC) at the European Laboratory for Particle Physics (CERN). For CMS an inner tracking system entirely equipped with silicon microstrip detectors was chosen. With an active area of about 198 m2 it will be the largest tracking device of the world that was ever constructed using silicon sensors. The basic components in the construction of the tracking system are approximately 16,000 so-called modules, which are pre-assembled units consisting of the sensors, the readout electronics and a support structure. The module production is carried out by a cooperation of number of institutes and industrial companies. To ensure the operation of the modules within the harsh radiation environment extensive tests have to be performed on all components. An important contribution to the quality assurance of the modules is made by a test system of which all components were developed in Aachen. In ad...

  4. Grid Interoperation with ARC middleware for the CMS experiment

    International Nuclear Information System (INIS)

    Edelmann, Erik; Groenager, Michael; Johansson, Daniel; Kleist, Josva; Field, Laurence; Qing, Di; Frey, Jaime; Happonen, Kalle; Klem, Jukka; Koivumaeki, Jesper; Linden, Tomas; Pirinen, Antti

    2010-01-01

    The Compact Muon Solenoid (CMS) is one of the general purpose experiments at the CERN Large Hadron Collider (LHC). CMS computing relies on different grid infrastructures to provide computational and storage resources. The major grid middleware stacks used for CMS computing are gLite, Open Science Grid (OSG) and ARC (Advanced Resource Connector). Helsinki Institute of Physics (HIP) hosts one of the Tier-2 centers for CMS computing. CMS Tier-2 centers operate software systems for data transfers (PhEDEx), Monte Carlo production (ProdAgent) and data analysis (CRAB). In order to provide the Tier-2 services for CMS, HIP uses tools and components from both ARC and gLite grid middleware stacks. Interoperation between grid systems is a challenging problem and HIP uses two different solutions to provide the needed services. The first solution is based on gLite-ARC grid level interoperability. This allows to use ARC resources in CMS without modifying the CMS application software. The second solution is based on developing specific ARC plugins in CMS software.

  5. Grid Interoperation with ARC middleware for the CMS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Edelmann, Erik; Groenager, Michael; Johansson, Daniel; Kleist, Josva [Nordic DataGrid Facility, Kastruplundgade 22, 1., DK-2770 Kastrup (Denmark); Field, Laurence; Qing, Di [CERN, CH-1211 Geneve 23 (Switzerland); Frey, Jaime [University of Wisconsin-Madison, 1210 W. Dayton St., Madison, WI (United States); Happonen, Kalle; Klem, Jukka; Koivumaeki, Jesper; Linden, Tomas; Pirinen, Antti, E-mail: Jukka.Klem@cern.c [Helsinki Institute of Physics, PO Box 64, FIN-00014 University of Helsinki (Finland)

    2010-04-01

    The Compact Muon Solenoid (CMS) is one of the general purpose experiments at the CERN Large Hadron Collider (LHC). CMS computing relies on different grid infrastructures to provide computational and storage resources. The major grid middleware stacks used for CMS computing are gLite, Open Science Grid (OSG) and ARC (Advanced Resource Connector). Helsinki Institute of Physics (HIP) hosts one of the Tier-2 centers for CMS computing. CMS Tier-2 centers operate software systems for data transfers (PhEDEx), Monte Carlo production (ProdAgent) and data analysis (CRAB). In order to provide the Tier-2 services for CMS, HIP uses tools and components from both ARC and gLite grid middleware stacks. Interoperation between grid systems is a challenging problem and HIP uses two different solutions to provide the needed services. The first solution is based on gLite-ARC grid level interoperability. This allows to use ARC resources in CMS without modifying the CMS application software. The second solution is based on developing specific ARC plugins in CMS software.

  6. Forward physics with CMS

    CERN Document Server

    Grothe, Monika

    2008-01-01

    Forward physics with CMS at the LHC covers a wide range of physics subjects, including very low-x_Bj QCD, underlying event and multiple interactions characteristics, gamma-mediated processes, shower development at the energy scale of primary cosmic ray interactions with the atmosphere, diffraction in the presence of a hard scale and even MSSM Higgs discovery in central exclusive production. Selected feasibility studies to illustrate the forward physics potential of CMS are presented.

  7. CMS: Present status, limitations, and upgrade plans

    International Nuclear Information System (INIS)

    Cheung, H.W.K.

    2011-01-01

    An overview of the CMS upgrade plans will be presented. A brief status of the CMS detector will be given, covering some of the issues we have so far experienced. This will be followed by an overview of the various CMS upgrades planned, covering the main motivations for them, and the various R and D efforts for the possibilities under study. The CMS detector has been working extremely well since the start of data-taking at the LHC as is evidenced by the numerous excellent results published by CMS and presented at this workshop and recent conferences. Less well documented are the various issues that have been encountered with the detector. In the spirit of this workshop I will cover some of these issues with particular emphasis on problems that motivate some of the upgrades to the CMS detector for this decade of data-taking. Though the CMS detector has been working extremely well and expectations are great for making the most of the LHC luminosity, there have been a number of issues encountered so far. Some of these have been described and while none currently presents a problem for physics performance, some of them are expected to become more problematic, especially at the highest Phase 1 luminosities for which the majority of the integrated luminosity will be collected. These motivate upgrades for various parts of the CMS detector so that the current excellent physics performance can be maintained or even surpassed in the realm of the highest Phase 1 luminosities.

  8. 100 Gbps PCI-Express readout for the LHCb upgrade

    International Nuclear Information System (INIS)

    Durante, P.; Neufeld, N.; Schwemmer, R.; Balbi, G.; Marconi, U.

    2015-01-01

    We present a new data acquisition system under development for the next upgrade of the LHCb experiment at CERN. We focus in particular on the design of a new generation of readout boards, the PCIe40, and on the viability of PCI-Express as an interconnect technology for high speed readout. We show throughput measurements across the PCI-Express bus, on Altera Stratix 5 devices, using a DMA mechanism and different synchronization schemes between the FPGA and the readout unit. Finally we discuss hardware and software design considerations necessary to achieve a data throughput of 100 Gbps in the final readout board

  9. Distributed Grid Experiences in CMS DC04

    CERN Document Server

    Fanfani, A; Grandi, C; Legrand, I; Suresh, S; Campana, S; Donno, F; Jank, W; Sinanis, N; Sciabà, A; García-Abia, P; Hernández, J; Ernst, M; Anzar, A; Fisk, I; Giacchetti, L; Graham, G; Heavey, A; Kaiser, J; Kuropatine, N; Perelmutov, T; Pordes, R; Ratnikova, N; Weigand, J; Wu, Y; Colling, D J; MacEvoy, B; Tallini, H; Wakefield, L; De Filippis, N; Donvito, G; Maggi, G; Bonacorsi, D; Dell'Agnello, L; Martelli, B; Biasotto, M; Fantinel, S; Corvo, M; Fanzago, F; Mazzucato, M; Tuura, L; Martin, T; Letts, J; Bockjoo, K; Prescott, C; Rodríguez, J; Zahn, A; Bradley, D

    2005-01-01

    In March-April 2004 the CMS experiment undertook a Data Challenge (DC04). During the previous 8 months CMS undertook a large simulated event production. The goal of the challenge was to run CMS reconstruction for sustained period at 25Hz in put rate, distribute the data to the CMS Tier-1 centers and analyze them at remote sites. Grid environments developed in Europe by the LHC Computing Grid (LCG) and in the US with Grid2003 were utilized to complete the aspects of the challenge. A description of the experiences, successes and lessons learned from both experiences with grid infrastructure is presented.

  10. Award for the best CMS thesis

    CERN Multimedia

    2003-01-01

    The 2002 CMS PhD Thesis Award for has been presented to Giacomo Luca Bruno for his thesis defended at the University of Pavia in Italy and entitled "The RPC detectors and the muon system for the CMS experiment at the LHC". His work was supervised by Sergio P. Ratti from the University of Pavia. Since April 2002, Giacomo has been employed as a research fellow by CERN's EP Division. He continues to work on CMS in the areas of data acquisition and physics reconstruction and selection. Last Monday he received a commemorative engraved plaque from Lorenzo Foà, chairman of the CMS Collaboration Board. He will also receive expenses paid to an international physics conference to present his thesis results. Giacomo Luca Bruno with Lorenzo Foà

  11. The CMS High Level Trigger System

    CERN Document Server

    Afaq, A; Bauer, G; Biery, K; Boyer, V; Branson, J; Brett, A; Cano, E; Carboni, A; Cheung, H; Ciganek, M; Cittolin, S; Dagenhart, W; Erhan, S; Gigi, D; Glege, F; Gómez-Reino, Robert; Gulmini, M; Gutiérrez-Mlot, E; Gutleber, J; Jacobs, C; Kim, J C; Klute, M; Kowalkowski, J; Lipeles, E; Lopez-Perez, Juan Antonio; Maron, G; Meijers, F; Meschi, E; Moser, R; Murray, S; Oh, A; Orsini, L; Paus, C; Petrucci, A; Pieri, M; Pollet, L; Rácz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Sexton-Kennedy, E; Sumorok, K; Suzuki, I; Tsirigkas, D; Varela, J

    2007-01-01

    The CMS Data Acquisition (DAQ) System relies on a purely software driven High Level Trigger (HLT) to reduce the full Level-1 accept rate of 100 kHz to approximately 100 Hz for archiving and later offline analysis. The HLT operates on the full information of events assembled by an event builder collecting detector data from the CMS front-end systems. The HLT software consists of a sequence of reconstruction and filtering modules executed on a farm of O(1000) CPUs built from commodity hardware. This paper presents the architecture of the CMS HLT, which integrates the CMS reconstruction framework in the online environment. The mechanisms to configure, control, and monitor the Filter Farm and the procedures to validate the filtering code within the DAQ environment are described.

  12. The CMS Data Analysis School Experience

    Energy Technology Data Exchange (ETDEWEB)

    De Filippis, N. [INFN, Bari; Bauerdick, L. [Fermilab; Chen, J. [Taiwan, Natl. Taiwan U.; Gallo, E. [DESY; Klima, B. [Fermilab; Malik, S. [Puerto Rico U., Mayaguez; Mulders, M. [CERN; Palla, F. [INFN, Pisa; Rolandi, G. [Pisa, Scuola Normale Superiore

    2017-11-21

    The CMS Data Analysis School is an official event organized by the CMS Collaboration to teach students and post-docs how to perform a physics analysis. The school is coordinated by the CMS schools committee and was first implemented at the LHC Physics Center at Fermilab in 2010. As part of the training, there are a number of “short” exercises on physics object reconstruction and identification, Monte Carlo simulation, and statistical analysis, which are followed by “long” exercises based on physics analyses. Some of the long exercises go beyond the current state of the art of the corresponding CMS analyses. This paper describes the goals of the school, the preparations for a school, the structure of the training, and student satisfaction with the experience as measured by surveys.

  13. Grid Interoperation with ARC Middleware for the CMS Experiment

    CERN Document Server

    Edelmann, Erik; Frey, Jaime; Gronager, Michael; Happonen, Kalle; Johansson, Daniel; Kleist, Josva; Klem, Jukka; Koivumaki, Jesper; Linden, Tomas; Pirinen, Antti; Qing, Di

    2010-01-01

    The Compact Muon Solenoid (CMS) is one of the general purpose experiments at the CERN Large Hadron Collider (LHC). CMS computing relies on different grid infrastructures to provide computational and storage resources. The major grid middleware stacks used for CMS computing are gLite, Open Science Grid (OSG) and ARC (Advanced Resource Connector). Helsinki Institute of Physics (HIP) hosts one of the Tier-2 centers for CMS computing. CMS Tier-2 centers operate software systems for data transfers (PhEDEx), Monte Carlo production (ProdAgent) and data analysis (CRAB). In order to provide the Tier-2 services for CMS, HIP uses tools and components from both ARC and gLite grid middleware stacks. Interoperation between grid systems is a challenging problem and HIP uses two different solutions to provide the needed services. The first solution is based on gLite-ARC grid level interoperability. This allows to use ARC resources in CMS without modifying the CMS application software. The second solution is based on developi...

  14. CMS Create #2 | 3-4 October | Register now!

    CERN Multimedia

    2016-01-01

    CMS Create brings together CERN members and students from IPAC Design Genève (see here). The goal is to build a prototype exhibit illustrating what CMS does and how it does it. The exhibit will introduce the world of a particle physics detector to the general public, and to younger visitors in particular.    CMS Create, hosted by IdeaSquare, was first held in November 2015. There were 4 highly diverse teams made of participants from many educational backgrounds and from 15 nationalities. 36% of these were women; a figure we hope will grow this year. The 25 participants were CMS physicists, computer scientists, engineers, other CMS collaborators and IPAC students. The 2015 winning exhibit is now permanently installed in the visitor reception centre at CMS Point 5, which was visited by 20.600 visitors during 2015. Are you creative and motivated to share your ideas?  Take part in CMS Create #2, meet with scientists and designers from all over the world and explain to CER...

  15. CMS Data Analysis: Current Status and Future Strategy

    CERN Document Server

    Innocente, V

    2003-01-01

    We present the current status of CMS data analysis architecture and describe work on future Grid-based distributed analysis prototypes. CMS has two main software frameworks related to data analysis: COBRA, the main framework, and IGUANA, the interactive visualisation framework. Software using these frameworks is used today in the world-wide production and analysis of CMS data. We describe their overall design and present examples of their current use with emphasis on interactive analysis. CMS is currently developing remote analysis prototypes, including one based on Clarens, a Grid-enabled client-server tool. Use of the prototypes by CMS physicists will guide us in forming a Grid-enriched analysis strategy. The status of this work is presented, as is an outline of how we plan to leverage the power of our existing frameworks in the migration of CMS software to the Grid.

  16. A Fastbus-based silicon strip readout system

    International Nuclear Information System (INIS)

    Neoustroev, P.; Stepanov, V.; Svoiski, M.; Uvarov, L.; Matthew, P.; Russ, J.; Cooper, P.

    1995-01-01

    The readout system we describe here is built specifically to work with the LBL-designed SVX chip. It is typical of systems using a master sequencer module to direct the trigger and readout cycles of the sparse data source and to push data into a digitization and storage module. (orig.)

  17. Performance of the Pixel Luminosity Telescope for Luminosity Measurement at CMS during Run 2

    CERN Document Server

    CMS Collaboration

    2017-01-01

    The Pixel Luminosity Telescope (PLT) is a dedicated system for luminosity measurement at the CMS experiment using silicon pixel sensors arranged into "telescopes", each consisting of three planes. It was installed during LS1 at the beginning of 2015 and has been providing online and offline luminosity measurements throughout Run 2. The online bunch-by-bunch luminosity measurement employs the "fast-or" capability of the pixel readout chip (PSI46) to identify events where a hit is registered in all three sensors in a telescope corresponding primarily to tracks originating from the interaction point. In addition, the full pixel information is read out at a lower rate, allowing for the calculation of corrections to the online luminosity from effects such as the miscounting of tracks not originating from the interaction point and detector efficiency. In this talk, we will present results from 2016 running and preliminary 2017 results, including commissioning and operational history, luminosity calibration using Va...

  18. CMS launches new educational tools

    CERN Document Server

    Corinne Pralavorio

    2014-01-01

    On 5 and 11 November, almost 90 pupils from the Fermi scientific high school in Livorno, Italy, took part in two Masterclass sessions organised by CMS.   CMS Masterclass participants.  The pupils took over a hall at CERN for an afternoon to test a new software tool called CIMA (CMS Instrument for Masterclass Analysis) for the first time. The software simplifies the process of recording results and reduces the number of steps required to enter data. During the exercise, each group of pupils had to analyse about a hundred events from the LHC. For each event, the budding physicists determined whether what they saw was a candidate W boson, Z boson or Higgs boson, identified the decay mode and entered key data. At the end of the analysis, they used the results to reconstruct a mass diagram. CIMA was developed by a team of scientists from the University of Aachen, Germany, the University of Notre-Dame, United States, and CERN. CMS has also added yet another educational tool to its already l...

  19. The CMS Electronic Logbook

    CERN Multimedia

    Bukowiec, S; Beccati, B; Behrens, U; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa Perez, J A; Deldicque, C; Erhan, S; Gigi, D; Glege, F; Gomez-Reino, R; Hatton, D; Hwong, Y L; Loizides, C; Ma, F; Masetti, L; Meijers, F; Meschi, E; Meyer, A; Mommsen, R K; Moser, R; O’Dell, V; Orsini, L; Paus, C; Petrucci, A; Pieri, M; Racz, A; Raginel, O; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, M; Sumorok, K; Sungho Yoon, A

    2010-01-01

    The CMS ELogbook (ELog) is a collaborative tool, which provides a platform to share and store information about various events or problems occurring in the Compact Muon Solenoid (CMS) experiment at CERN during operation. The ELog is based on a Model–View–Controller (MVC) software architectural pattern and uses an Oracle database to store messages and attachments. The ELog is developed as a pluggable web component in Oracle Portal in order to provide better management, monitoring and security.

  20. Improving collaborative documentation in CMS

    International Nuclear Information System (INIS)

    Lassila-Perini, Kati; Salmi, Leena

    2010-01-01

    Complete and up-to-date documentation is essential for efficient data analysis in a large and complex collaboration like CMS. Good documentation reduces the time spent in problem solving for users and software developers. The scientists in our research environment do not necessarily have the interests or skills of professional technical writers. This results in inconsistencies in the documentation. To improve the quality, we have started a multidisciplinary project involving CMS user support and expertise in technical communication from the University of Turku, Finland. In this paper, we present possible approaches to study the usability of the documentation, for instance, usability tests conducted recently for the CMS software and computing user documentation.

  1. A compact readout system for multi-pixel hybrid photodiodes

    International Nuclear Information System (INIS)

    Datema, C.P.; Meng, L.J.; Ramsden, D.

    1999-01-01

    Although the first Multi-pixel Hybrid Photodiode (M-HPD) was developed in the early 1990s by Delft Electronic Products, the main obstacle to its application has been the lack of availability of a compact read-out system. A fast, parallel readout system has been constructed for use with the earlier 25-pixel tube with High-energy Physics applications in mind. The excellent properties of the recently developed multi-pixel hybrid photodiodes (M-HPD) will be easier to exploit following the development of the new hybrid read-out circuits described in this paper. This system will enable all of the required read-out functions to be accommodate on a single board into which the M-HPD is plugged. The design and performance of a versatile system is described in which a trigger-signal, derived from the common-side of the silicon anode in the M-HPD, is used to trigger the readout of the 60-anode pixels in the M-HPD. The multi-channel amplifier section is based on the use of a new, commercial VLSI chip, whilst the read-out sequencer uses a chip of its own design. The common anode signal is processed by a fast amplifier and discriminator to provide a trigger signal when a single event is detected. In the prototype version, the serial analogue output data-stream is processed using a PC-mounted, high speed ADC. Results obtained using the new read-out system in a compact gamma-camera and with a small muon tracking-chamber demonstrate the low-noise performance of the system. The application of this read-out system in other position-sensitive or multi-anode photomultiplier tube applications are also described

  2. arXiv Performance verification of the CMS Phase-1 Upgrade Pixel detector

    CERN Document Server

    Veszpremi, Viktor

    2017-12-04

    The CMS tracker consists of two tracking systems utilizing semiconductor technology: the inner pixel and the outer strip detectors. The tracker detectors occupy the volume around the beam interaction region between 3 cm and 110 cm in radius and up to 280 cm along the beam axis. The pixel detector consists of 124 million pixels, corresponding to about 2 m 2 total area. It plays a vital role in the seeding of the track reconstruction algorithms and in the reconstruction of primary interactions and secondary decay vertices. It is surrounded by the strip tracker with 10 million read-out channels, corresponding to 200 m 2 total area. The tracker is operated in a high-occupancy and high-radiation environment established by particle collisions in the LHC . The current strip detector continues to perform very well. The pixel detector that has been used in Run 1 and in the first half of Run 2 was, however, replaced with the so-called Phase-1 Upgrade detector. The new system is better suited to match the increased inst...

  3. Estudio de un microcable de par trenzado para la comunicacion y lectura del modulo de pixeles del experimento CMS

    Science.gov (United States)

    Oliveros Tautiva, Sandra Jimena

    The Compact Muon Solenoid (CMS) is one of the two most important experiments at the Large Hadron Collider (LHC). The pixel detector is the component closest to the collision in CMS and it receives large doses of radiation which will affect its performance. The pixel detector will be replaced by a new one after four years. The aim is to reduce material in the sensitive zone of the new pixel detector, which leads to the implementation of a type of micro twisted pair cable that will replace the existing kapton cables and some connections will be eliminated. The purpose of this work was to study the viability of using these micro twisted pair cables in the existing 40 MHz analog readout. The electrical parameters of micro cables were determined, and operational tests were performed in a module using these cables for communicating and reading. Three different lengths of micro cables were used, 1.0, 1.5 and 2.0 m, in order to compare test results with those obtained using the kapton cable. It was found that the use of these cables does not affect the programming and reading of the pixels in one module, so the micro cables are viable to be used in place of the kapton cables.

  4. Exploiting Analytics Techniques in CMS Computing Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bonacorsi, D. [Bologna U.; Kuznetsov, V. [Cornell U.; Magini, N. [Fermilab; Repečka, A. [Vilnius U.; Vaandering, E. [Fermilab

    2017-11-22

    The CMS experiment has collected an enormous volume of metadata about its computing operations in its monitoring systems, describing its experience in operating all of the CMS workflows on all of the Worldwide LHC Computing Grid Tiers. Data mining efforts into all these information have rarely been done, but are of crucial importance for a better understanding of how CMS did successful operations, and to reach an adequate and adaptive modelling of the CMS operations, in order to allow detailed optimizations and eventually a prediction of system behaviours. These data are now streamed into the CERN Hadoop data cluster for further analysis. Specific sets of information (e.g. data on how many replicas of datasets CMS wrote on disks at WLCG Tiers, data on which datasets were primarily requested for analysis, etc) were collected on Hadoop and processed with MapReduce applications profiting of the parallelization on the Hadoop cluster. We present the implementation of new monitoring applications on Hadoop, and discuss the new possibilities in CMS computing monitoring introduced with the ability to quickly process big data sets from mulltiple sources, looking forward to a predictive modeling of the system.

  5. Towards higher reliability of CMS computing facilities

    International Nuclear Information System (INIS)

    Bagliesi, G; Bloom, K; Brew, C; Flix, J; Kreuzer, P; Sciabà, A

    2012-01-01

    The CMS experiment has adopted a computing system where resources are distributed worldwide in more than 50 sites. The operation of the system requires a stable and reliable behaviour of the underlying infrastructure. CMS has established procedures to extensively test all relevant aspects of a site and their capability to sustain the various CMS computing workflows at the required scale. The Site Readiness monitoring infrastructure has been instrumental in understanding how the system as a whole was improving towards LHC operations, measuring the reliability of sites when running CMS activities, and providing sites with the information they need to troubleshoot any problem. This contribution reviews the complete automation of the Site Readiness program, with the description of monitoring tools and their inclusion into the Site Status Board (SSB), the performance checks, the use of tools like HammerCloud, and the impact in improving the overall reliability of the Grid from the point of view of the CMS computing system. These results are used by CMS to select good sites to conduct workflows, in order to maximize workflows efficiencies. The performance against these tests seen at the sites during the first years of LHC running is as well reviewed.

  6. VIP visit to CERN P5 CMS of Pakistan Science Members

    CERN Multimedia

    Hoch, Michael

    2012-01-01

    VIP visit to CERN P5 CMS of PAEC & JCPC Science Members List of PAEC Visitors: Dr. Badar Suleman - Member Science PAEC & Member of JCPC Dr. Waqar M. Butt - Member Engineering (Head of HMC3) Dr. Maqsood Ahmad - Chief Scientist (Head of Accelerator Project) List of CMS participants: Prof. Joseph Incandela, CMS Spokesperson Dr. Austin Ball, CMS Technical Coordinator Mr Andrzej Charkiewicz, CMS Resources Manager Dr. Michael Hoch, CMS Outreach activities, CMS photographer and guide Dr. Achille Petrilli, CMS Team Leader

  7. SUSY searches in early CMS data

    International Nuclear Information System (INIS)

    Tricomi, A

    2008-01-01

    In the first year of data taking at LHC, the CMS experiment expects to collect about 1 fb -1 of data, which make possible the first searches for new phenomena. All such searches require however the measurement of the SM background and a detailed understanding of the detector performance, reconstruction algorithms and triggering. The CMS efforts are hence addressed to designing a realistic analysis plan in preparation to the data taking. In this paper, the CMS perspectives and analysis strategies for Supersymmetry (SUSY) discovery with early data are presented

  8. CP violation in CMS expected performance

    CERN Document Server

    Stefanescu, J

    1999-01-01

    The CMS experiment can contribute significantly to the measurement of the CP violation asymmetries. A recent evaluation of the expected precision on the CP violation parameter sin 2 beta in the channel B /sub d//sup 0/ to J/ psi $9 K/sub s//sup 0/ has been performed using a simulation of the CMS tracker including full pattern recognition. CMS has also studied the possibility to observe CP violation in the decay channel B/sub s//sup 0/ to J/ psi phi . The $9 results of these studies are reviewed. (7 refs).

  9. Frequency-chirped readout of spatial-spectral absorption features

    International Nuclear Information System (INIS)

    Chang, Tiejun; Mohan, R. Krishna; Harris, Todd L.; Merkel, Kristian D.; Tian Mingzhen; Babbitt, Wm. Randall

    2004-01-01

    This paper examines the physical mechanisms of reading out spatial-spectral absorption features in an inhomogeneously broadened medium using linear frequency-chirped electric fields. A Maxwell-Bloch model using numerical calculation for angled beams with arbitrary phase modulation is used to simulate the chirped field readout process. The simulation results indicate that any spatial-spectral absorption feature can be read out with a chirped field with the appropriate bandwidth, duration, and intensity. Mapping spectral absorption features into temporal intensity modulations depends on the chirp rate of the field. However, when probing a spatial-spectral grating with a chirped field, a beat signal representing the grating period can be created by interfering the emitted photon echo chirped field with a reference chirped field, regardless of the chirp rate. Comparisons are made between collinear and angled readout configurations. Readout signal strength and spurious signal distortions are investigated as functions of the grating strength and the Rabi frequency of the readout pulse. Using a collinear readout geometry, distortions from optical nutation on the transmitted field and higher-order harmonics are observed, both of which are avoided in an angled beam geometry

  10. 42 CFR 426.517 - CMS' statement regarding new evidence.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false CMS' statement regarding new evidence. 426.517... DETERMINATIONS Review of an NCD § 426.517 CMS' statement regarding new evidence. (a) CMS may review any new... experts; and (5) Presented during any hearing. (b) CMS may submit a statement regarding whether the new...

  11. Novel trigger-capable modules for the future CMS tracking detector and inclusive top quark pair production cross section at √(s)=13 TeV

    Energy Technology Data Exchange (ETDEWEB)

    Harb, Ali

    2017-07-15

    This work covers two important aspects in the field of high-energy physics; detector development and physics data analysis. The first part of this thesis is devoted to the detector development activities for the Phase-II upgrade of the Compact Muon Solenoid (CMS) experiment's outer tracking detector. To cope with the increased luminosity during the high-luminosity era of the Large Hadron Collider (LHC), it is foreseen to replace the existing tracking system of CMS with an entirely new system. Owing to a novel module concept called the p{sub T}-module, the upgraded tracking system will be able to provide first level trigger information by means of an on-board momentum discrimination logic. This will be achieved using a new readout chip, the so-called CMS Binary Chip (CBC). The very first test beam measurement using p{sub T}-module prototypes, equipped with the CBC chip is presented and discussed. The obtained results serve as a proof-of-concept for such modules and shows that the CBC performs as expected. In the second part of this thesis, the measurement of the top quark pair production cross section is addressed. The measurement is performed using 2.2 fb{sup -1} of data collected by the CMS detector at a center-of-mass energy of 13 TeV. Results are shown in the eμ di-lepton channel, and for the first time at such energy, in the ee and μμ channels. With an improved treatment of systematic uncertainties, the results in all three channels are found to be in agreement with the theoretical predictions.

  12. Set of CMS posters in Spanish

    CERN Multimedia

    Lapka, Marzena; Rao, Achintya

    2014-01-01

    14 A0 posters in English to be printed locally or displayed online. Purpose: science fairs, exhibitions, preparatory material for the CMS virtual visits, etc. Themes: CMS detector, sub-detectors, construction, lowering and installation, collaboration and physics. Available in many languages.

  13. Set of CMS posters in Greek

    CERN Multimedia

    Lapka, Marzena; Petrilli, Achille

    2015-01-01

    14 A0 posters in English to be printed locally or displayed online. Purpose: science fairs, exhibitions, preparatory material for the CMS virtual visits, etc. Themes: CMS detector, sub-detectors, construction, lowering and installation, collaboration and physics. Available in many languages.

  14. Set of CMS posters (multiple languages)

    CERN Multimedia

    Lapka, Marzena; Rao, Achintya

    2014-01-01

    14 A0 posters in English to be printed locally or displayed online. Purpose: science fairs, exhibitions, preparatory material for the CMS virtual visits, etc. Themes: CMS detector, sub-detectors, construction, lowering and installation, collaboration and physics. Available in many languages.

  15. A search for a heavy Majorana neutrino and a radiation damage simulation for the HF detector

    Science.gov (United States)

    Wetzel, James William

    A search for heavy Majorana neutrinos is performed using an event signature defined by two same-sign muons accompanied by two jets. This search is an extension of previous searches, (L3, DELPHI, CMS, ATLAS), using 19.7 fb -1 of data from the 2012 Large Hadron Collider experimental run collected by the Compact Muon Solenoid experiment. A mass window of 40-500 GeV/ c2 is explored. No excess events above Standard Model backgrounds is observed, and limits are set on the mixing element squared, |VmuN|2, as a function of Majorana neutFnrino mass. The Hadronic Forward (HF) Detector's performance will degrade as a function of the number of particles delivered to the detector over time, a quantity referred to as integrated luminosity and measured in inverse femtobarns (fb-1). In order to better plan detector upgrades, the CMS Forward Calorimetry Task Force (FCAL) group and the CMS Hadronic Calorimeter (HCAL) group have requested that radiation damage be simulated and the subsequent performance of the HF subdetector be studied. The simulation was implemented into both the CMS FastSim and CMS FullSim simulation packages. Standard calorimetry performance metrics were computed and are reported. The HF detector can expect to perform well through the planned delivery of 3000 fb-1.

  16. FASTBUS Readout Controller card for high speed data acquisition

    International Nuclear Information System (INIS)

    Zimmermann, S.

    1991-10-01

    This article describes a FASTBUS Readout Controller (FRC) for high speed data acquisition in FASTBUS based systems. The controller has two main interfaces: to FASTBUS and to a Readout Port. The FASTBUS interface performs FASTBUS master and slave operations at a maximum transfer rate exceeding 40 MBytes/s. The Readout Port can be adapted for a variety of protocols. Currently, it will be interfaced to a VME bus based processor with a VSB port. The on-board LR33000 embedded processor controls the readout, executing a list of operations download into its memory. It scans the FASTBUS modules and stores the data in a triple port DRAM (TPDRAM), through one of the Serial Access Memory (SAM) ports of the (TPDRAM). Later, it transfers this data to the readout port using the other SAM. The FRC also supports serial communication via RS232 and Ethernet interfaces. This device is intended for use in the data acquisition system at the Collider Detector at Fermilab. 5 refs., 3 figs

  17. The Latest from CMS

    CERN Multimedia

    2009-01-01

    CMS is on track to be ready for physics one month in advance of the LHC restart. The final installations are being completed and tests are being run to ensure that the experiment is as well prepared as possible to exploit sustained LHC operation throughout 2010. Physics week in Bologna, Italy, was a valuable time for CMS collaborators to discuss preparations for numerous physics analyses, as well as the performance of the detector during the recent data-taking period with cosmics (CRAFT 09). During this five-week exercise, more than 300 million cosmic events were recorded with the magnetic field on. This large data-set is being used to further improve the sub-detector alignment, calibration and performance whilst awaiting p-p collisions. Meanwhile, in the experimental cavern, Wolfram Zeuner, Deputy Technical Coordinator of CMS, reports "We are now very nearly closed up again. We are just doing the final clean-up work and are ready t...

  18. CMS outreach event to close LS1

    CERN Multimedia

    Achintya Rao

    2015-01-01

    CMS opened its doors to about 700 students from schools near CERN, who visited the detector on 16 and 17 February during the last major CMS outreach event of LS1.   Pellentesque sapien mi, pharetra vitae, auctor eu, congue sed, turpis. Enthusiastic CMS guides spent a day and a half showing the equally enthusiastic visitors, aged 10 to 18, the beauty of CMS and particle physics. The recently installed wheelchair lift was called into action and enabled a visitor who arrived on crutches to access the detector cavern unimpeded.  The CMS collaboration had previously devoted a day to school visits after the successful “Neighbourhood Days” in May 2014 and, encouraged by the turnout, decided to extend an invitation to local schools once again. The complement of nearly 40 guides and crowd marshals was aided by a support team that coordinated the transportation of the young guests and received them at Point 5, where a dedicated safety team including first-aiders, security...

  19. CMS Centres Worldwide - a New Collaborative Infrastructure

    CERN Document Server

    Taylor, Lucas

    2011-01-01

    Webcasts, and generic Web tools such as CMS-TV for broadcasting live monitoring and outreach information. Being Web-based and experiment-independent, these systems could easily be extended to other organizations. We describe the experiences of using CMS Centres Worldwide in the CMS data-taking operations as well as for major media events with several hundred TV channels, radio stations, and many more press journalists simultaneously around the world.

  20. 42 CFR 423.2264 - Guidelines for CMS review.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Guidelines for CMS review. 423.2264 Section 423....2264 Guidelines for CMS review. In reviewing marketing material or enrollment forms under § 423.2262, CMS determines (unless otherwise specified in additional guidance) that the marketing materials— (a...

  1. Radiation effects in electronics for the CMS tracking detector

    International Nuclear Information System (INIS)

    Fulcher, Jonathan Richard

    2001-01-01

    This thesis presents a study into the CMS tracker analogue front-end amplifier readout chip (APV), which during the period of the study was fabricated in three different VLSI technologies. The early versions were fabricated in a total dose radiation hardened Harris 1.2μm process. Later it was transferred to a DMILL 0.8μm process and the latest version is in a 0.25μm technology. Part of this thesis describes a test system which was designed to thoroughly test APV chips on the silicon wafer and produce a comprehensive data set for each chip to enable confident selection of good chips. The main study is on the effects that large dose radiation environments can cause in the individual parts of the chip. With the chips fabricated in different technologies it was possible to make some comparisons of the magnitude of the effects between the Harris and the 0.25μm technologies, but most of the work was aimed towards understanding the effects within the 0.25μm technology. Single Event Upset (SEU) was the main consideration behind the experimental and simulation work. The study had two main goals: the first was to investigate how SEU would affect the operation of the CMS detector in the expected high radiation environment of the Large Hadron Collider (LHC). The second goal was to look at SEU from a more academic viewpoint, enabling a full understanding of how it is caused and what factors affect its magnitude. Simulations were performed in order to reconstruct the conditions brought about by highly ionising particles striking certain parts of the sensitive circuits, along with careful consideration of the mechanisms behind the effect such as: ionised charge collection within the semiconductor parts of the chip, how this charge deposition affects the circuit and how the effects manifest themselves within larger devices. A good set of results was collected from specially designed experiments, from which a confirmation of the theoretical effect was produced. (author)

  2. Predicting dataset popularity for the CMS experiment

    CERN Document Server

    INSPIRE-00005122; Li, Ting; Giommi, Luca; Bonacorsi, Daniele; Wildish, Tony

    2016-01-01

    The CMS experiment at the LHC accelerator at CERN relies on its computing infrastructure to stay at the frontier of High Energy Physics, searching for new phenomena and making discoveries. Even though computing plays a significant role in physics analysis we rarely use its data to predict the system behavior itself. A basic information about computing resources, user activities and site utilization can be really useful for improving the throughput of the system and its management. In this paper, we discuss a first CMS analysis of dataset popularity based on CMS meta-data which can be used as a model for dynamic data placement and provide the foundation of data-driven approach for the CMS computing infrastructure.

  3. Predicting dataset popularity for the CMS experiment

    International Nuclear Information System (INIS)

    Kuznetsov, V.; Li, T.; Giommi, L.; Bonacorsi, D.; Wildish, T.

    2016-01-01

    The CMS experiment at the LHC accelerator at CERN relies on its computing infrastructure to stay at the frontier of High Energy Physics, searching for new phenomena and making discoveries. Even though computing plays a significant role in physics analysis we rarely use its data to predict the system behavior itself. A basic information about computing resources, user activities and site utilization can be really useful for improving the throughput of the system and its management. In this paper, we discuss a first CMS analysis of dataset popularity based on CMS meta-data which can be used as a model for dynamic data placement and provide the foundation of data-driven approach for the CMS computing infrastructure. (paper)

  4. The CMS Electromagnetic Calorimeter: Construction, Commissioning and Calibration

    CERN Document Server

    Orimoto, Toyoko

    2009-01-01

    The Compact Muon Solenoid (CMS) detector at the Large Hadron Colider (LHC) is ready for first collisions. The Electromagnetic Calorimeter (ECAL) of CMS, a high resolution detector comprised of nearly 76000 lead tungstate crystals, will play a crucial role in the coming physics searches undertaken by CMS. The design and performance of the CMS ECAL with test beams, cosmic rays, and first single beam data will be presented. In addition, the status of the calorimeter and plans for calibration with first collisions will be discussed.

  5. The CMS CERN Analysis Facility (CAF)

    Energy Technology Data Exchange (ETDEWEB)

    Buchmueller, O [Imperial College (United Kingdom); Bonacorsi, D [Universita and INFN, Bologna (Italy); Fanzago, F [Universita and INFN, Padova (Italy); Gowdy, S; Malgeri, L; Panzer-Steindel, B; Schwickerath, U; Spiga, D; Toebbicke, Rainer [Conseil Europeen Recherche Nucl. (CERN) Switzerland (Switzerland); Kreuzer, P [Rheinisch-Westfaelische Tech. Hoch. (RWTH) (Germany); Mankel, R [Deutsches Elektronen-Synchrotron (DESY) (Germany); Metson, S [University of Bristol (United Kingdom); Sanches, J Afonso; Teodoro, D, E-mail: Peter.Kreuzer@cern.c [Universidade do Estado do Rio De Janeiro (UERJ) (Brazil)

    2010-04-01

    The CMS CERN Analysis Facility (CAF) was primarily designed to host a large variety of latency-critical workflows. These break down into alignment and calibration, detector commissioning and diagnosis, and high-interest physics analysis requiring fast-turnaround. In addition to the low latency requirement on the batch farm, another mandatory condition is the efficient access to the RAW detector data stored at the CERN Tier-0 facility. The CMS CAF also foresees resources for interactive login by a large number of CMS collaborators located at CERN, as an entry point for their day-by-day analysis. These resources will run on a separate partition in order to protect the high-priority use-cases described above. While the CMS CAF represents only a modest fraction of the overall CMS resources on the WLCG GRID, an appropriately sized user-support service needs to be provided. We will describe the building, commissioning and operation of the CMS CAF during the year 2008. The facility was heavily and routinely used by almost 250 users during multiple commissioning and data challenge periods. It reached a CPU capacity of 1.4MSI2K and a disk capacity at the Peta byte scale. In particular, we will focus on the performances in terms of networking, disk access and job efficiency and extrapolate prospects for the upcoming LHC first year data taking. We will also present the experience gained and the limitations observed in operating such a large facility, in which well controlled workflows are combined with more chaotic type analysis by a large number of physicists.

  6. The CMS CERN Analysis Facility (CAF)

    International Nuclear Information System (INIS)

    Buchmueller, O; Bonacorsi, D; Fanzago, F; Gowdy, S; Malgeri, L; Panzer-Steindel, B; Schwickerath, U; Spiga, D; Toebbicke, Rainer; Kreuzer, P; Mankel, R; Metson, S; Sanches, J Afonso; Teodoro, D

    2010-01-01

    The CMS CERN Analysis Facility (CAF) was primarily designed to host a large variety of latency-critical workflows. These break down into alignment and calibration, detector commissioning and diagnosis, and high-interest physics analysis requiring fast-turnaround. In addition to the low latency requirement on the batch farm, another mandatory condition is the efficient access to the RAW detector data stored at the CERN Tier-0 facility. The CMS CAF also foresees resources for interactive login by a large number of CMS collaborators located at CERN, as an entry point for their day-by-day analysis. These resources will run on a separate partition in order to protect the high-priority use-cases described above. While the CMS CAF represents only a modest fraction of the overall CMS resources on the WLCG GRID, an appropriately sized user-support service needs to be provided. We will describe the building, commissioning and operation of the CMS CAF during the year 2008. The facility was heavily and routinely used by almost 250 users during multiple commissioning and data challenge periods. It reached a CPU capacity of 1.4MSI2K and a disk capacity at the Peta byte scale. In particular, we will focus on the performances in terms of networking, disk access and job efficiency and extrapolate prospects for the upcoming LHC first year data taking. We will also present the experience gained and the limitations observed in operating such a large facility, in which well controlled workflows are combined with more chaotic type analysis by a large number of physicists.

  7. Model of CMS Tracker

    CERN Multimedia

    Breuker

    1999-01-01

    A full scale CMS tracker mock-up exposed temporarily in the hall of building 40. The purpose of the mock-up is to study the routing of services, assembly and installation. The people in front are only a small fraction of the CMS tracker collaboration. Left to right : M. Atac, R. Castaldi, H. Breuker, D. Pandoulas,P. Petagna, A. Caner, A. Carraro, H. Postema, M. Oriunno, S. da Mota Silva, L. Van Lancker, W. Glessing, G. Benefice, A. Onnela, M. Gaspar, G. M. Bilei

  8. The CMS DBS query language

    International Nuclear Information System (INIS)

    Kuznetsov, Valentin; Riley, Daniel; Afaq, Anzar; Sekhri, Vijay; Guo Yuyi; Lueking, Lee

    2010-01-01

    The CMS experiment has implemented a flexible and powerful system enabling users to find data within the CMS physics data catalog. The Dataset Bookkeeping Service (DBS) comprises a database and the services used to store and access metadata related to CMS physics data. To this, we have added a generalized query system in addition to the existing web and programmatic interfaces to the DBS. This query system is based on a query language that hides the complexity of the underlying database structure by discovering the join conditions between database tables. This provides a way of querying the system that is simple and straightforward for CMS data managers and physicists to use without requiring knowledge of the database tables or keys. The DBS Query Language uses the ANTLR tool to build the input query parser and tokenizer, followed by a query builder that uses a graph representation of the DBS schema to construct the SQL query sent to underlying database. We will describe the design of the query system, provide details of the language components and overview of how this component fits into the overall data discovery system architecture.

  9. 42 CFR 460.18 - CMS evaluation of applications.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false CMS evaluation of applications. 460.18 Section 460... ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.18 CMS evaluation of applications. CMS evaluates an application for approval as a PACE organization on the basis of the following...

  10. A cosmic ray muon going through CMS with the magnet at full field. The line shows the path of the muon reconstructed from information recorded in the various detectors.

    CERN Multimedia

    Ianna, Osborne

    2007-01-01

    The event display of the event 3981 from the MTCC run 2605. The data has been taken with a magnetic field of 3.8 T. A detailed model of the magnetic field corresponding to 4T is shown as a color gradient from 4T in the center (red) to 0 T outside of the detector (blue). The cosmic muon has been detected by all four detectors participating in the run: the drift tubes, the HCAL, the tracker and the ECAL subdetectors and it has been reconstructed online. The event display shows the reconstructed 4D segments in the drift tubes (magenta), the reconstructed hits in HCAL (blue), the locally reconstructed track in the tracker (green), the uncalibrated rec hits in ECAL (light green). A muon track was reconstructed in the drift tubes and extrapolated back into the detector taking the magnetic field into account (green).

  11. Readout of the upgraded ALICE-ITS

    Science.gov (United States)

    Szczepankiewicz, A.; ALICE Collaboration

    2016-07-01

    The ALICE experiment will undergo a major upgrade during the second long shutdown of the CERN LHC. As part of this program, the present Inner Tracking System (ITS), which employs different layers of hybrid pixels, silicon drift and strip detectors, will be replaced by a completely new tracker composed of seven layers of monolithic active pixel sensors. The upgraded ITS will have more than twelve billion pixels in total, producing 300 Gbit/s of data when tracking 50 kHz Pb-Pb events. Two families of pixel chips realized with the TowerJazz CMOS imaging process have been developed as candidate sensors: the ALPIDE, which uses a proprietary readout and sparsification mechanism and the MISTRAL-O, based on a proven rolling shutter architecture. Both chips can operate in continuous mode, with the ALPIDE also supporting triggered operations. As the communication IP blocks are shared among the two chip families, it has been possible to develop a common Readout Electronics. All the sensor components (analog stages, state machines, buffers, FIFOs, etc.) have been modelled in a system level simulation, which has been extensively used to optimize both the sensor and the whole readout chain design in an iterative process. This contribution covers the progress of the R&D efforts and the overall expected performance of the ALICE-ITS readout system.

  12. Readout of the upgraded ALICE-ITS

    International Nuclear Information System (INIS)

    Szczepankiewicz, A.

    2016-01-01

    The ALICE experiment will undergo a major upgrade during the second long shutdown of the CERN LHC. As part of this program, the present Inner Tracking System (ITS), which employs different layers of hybrid pixels, silicon drift and strip detectors, will be replaced by a completely new tracker composed of seven layers of monolithic active pixel sensors. The upgraded ITS will have more than twelve billion pixels in total, producing 300 Gbit/s of data when tracking 50 kHz Pb–Pb events. Two families of pixel chips realized with the TowerJazz CMOS imaging process have been developed as candidate sensors: the ALPIDE, which uses a proprietary readout and sparsification mechanism and the MISTRAL-O, based on a proven rolling shutter architecture. Both chips can operate in continuous mode, with the ALPIDE also supporting triggered operations. As the communication IP blocks are shared among the two chip families, it has been possible to develop a common Readout Electronics. All the sensor components (analog stages, state machines, buffers, FIFOs, etc.) have been modelled in a system level simulation, which has been extensively used to optimize both the sensor and the whole readout chain design in an iterative process. This contribution covers the progress of the R&D efforts and the overall expected performance of the ALICE-ITS readout system.

  13. Readout of the upgraded ALICE-ITS

    Energy Technology Data Exchange (ETDEWEB)

    Szczepankiewicz, A., E-mail: Adam.Szczepankiewicz@cern.ch [CERN, Geneva (Switzerland); Institute of Computer Science, Warsaw University of Technology, Warsaw (Poland)

    2016-07-11

    The ALICE experiment will undergo a major upgrade during the second long shutdown of the CERN LHC. As part of this program, the present Inner Tracking System (ITS), which employs different layers of hybrid pixels, silicon drift and strip detectors, will be replaced by a completely new tracker composed of seven layers of monolithic active pixel sensors. The upgraded ITS will have more than twelve billion pixels in total, producing 300 Gbit/s of data when tracking 50 kHz Pb–Pb events. Two families of pixel chips realized with the TowerJazz CMOS imaging process have been developed as candidate sensors: the ALPIDE, which uses a proprietary readout and sparsification mechanism and the MISTRAL-O, based on a proven rolling shutter architecture. Both chips can operate in continuous mode, with the ALPIDE also supporting triggered operations. As the communication IP blocks are shared among the two chip families, it has been possible to develop a common Readout Electronics. All the sensor components (analog stages, state machines, buffers, FIFOs, etc.) have been modelled in a system level simulation, which has been extensively used to optimize both the sensor and the whole readout chain design in an iterative process. This contribution covers the progress of the R&D efforts and the overall expected performance of the ALICE-ITS readout system.

  14. Resistive Plate Chambers for hadron calorimetry: Tests with analog readout

    Energy Technology Data Exchange (ETDEWEB)

    Drake, Gary [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States); Repond, Jose [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States)]. E-mail: repond@hep.anl.gov; Underwood, David [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States); Xia, Lei [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States)

    2007-07-21

    Resistive Plate Chambers (RPCs) are being developed for use in a hadron calorimeter with very fine segmentation of the readout. The design of the chambers and various tests with cosmic rays are described. This paper reports on the measurements with multi-bit (or analog) readout of either a single larger or multiple smaller readout pads.

  15. Forward energy measurement with CMS

    CERN Document Server

    Kheyn, Lev

    2016-01-01

    Energy flow is measured in the forward region of CMS at pseudorapidities up to 6.6 in pp interactions at 13 TeV with forward (HF) and very forward (CASTOR) calorimeters. The results are compared to model predictions. The CMS results at different center-of-mass energies are intercompared using pseudorapidity variable shifted by beam rapidity, thus studying applicability of hypothesis of limiting fragmentation.

  16. 42 CFR 405.1834 - CMS reviewing official procedure.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false CMS reviewing official procedure. 405.1834 Section... Determinations and Appeals § 405.1834 CMS reviewing official procedure. (a) Scope. A provider that is a party to... Administrator by a designated CMS reviewing official who considers whether the decision of the intermediary...

  17. 42 CFR 422.2264 - Guidelines for CMS review.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Guidelines for CMS review. 422.2264 Section 422... Guidelines for CMS review. In reviewing marketing material or election forms under § 422.2262 of this part, CMS determines that the marketing materials— (a) Provide, in a format (and, where appropriate, print...

  18. Performance of the modules for layer 1 of the CMS phase 1 pixel detector upgrade

    CERN Document Server

    Meinhard, Maren Tabea; Berger, Pirmin; Starodumov, Andrey

    2017-01-01

    The instantaneous luminosity of the Large Hadron Collider will increase to up to 2x10$^{34}$\\;cm$^{-2}$s$^{-1}$ by 2023. In order to cope with such luminosities, the pixel detector of the CMS experiment has been replaced in January 2017. The upgraded detector features four sensitive layers in the barrel part. A designated readout chip (PROC600V2) is used for layer 1, which is closest to the interaction point and therefore has to handle larger particle fluxes. An irradiation campaign has been performed with PROC600V2 to verify its radiation tolerance up to the maximum expected dose for 2017 of 0.2\\;MGy. Modules for layer 1 have been built with PROC600V2 for the detector production. The quality of every inserted module was assessed in a number of tests, some of which were performed using X-radiation. The characteristics of the modules used in the detector as well as the main failure modes will be presented.

  19. Comparison of two highly granular hadronic calorimeter concepts

    International Nuclear Information System (INIS)

    Neubueser, Coralie

    2016-11-01

    The CALICE collaboration develops hadron calorimeter technologies with high granularity for future electron-positron linear colliders. These technologies differ in active material, granularity and their readout and thus their energy reconstruction schemes. The Analogue Hadron Calorimeter (AHCAL), based on scintillator tiles with Silicon Photomultiplier readout, measures the signal amplitude of the energy deposition in the cells of at most 3 x 3 cm"2 size. The Digital, Resistive Plate Chamber (RPC) based, HCAL (DHCAL) detects hits above a certain threshold by firing pad sensors of 1 x 1 cm"2. A 2 bit readout is provided by the, also RPC based, Semi-Digital HCAL (SDHCAL), which counts hits above three different thresholds per 1 x 1 cm"2 pad. All three calorimeter concepts have been realised in 1 m"3 prototypes with interleaved steel absorber and tested at various test beams. The differences in active medium, granularity and readout have different impacts on the energy resolution and need to be studied independently. This analysis concentrates on the comparison between these technologies by investigating the impact of the different energy reconstruction schemes on the energy resolution of the AHCAL testbeam data and simulation. Additionally, a so-called software compensation algorithm is developed to weight hits dependent on their energy content and correct for the difference in the response to the electromagnetic and hadronic sub-showers (e/h≠1) and thus reduce the influence of fluctuations in the π"0 generation. The comparison of the energy resolutions revealed that it is mandatory for the AHCAL with 3 x 3 cm"2 cell size to have analogue signal readout, to apply the software compensation algorithm and thus achieve the best possible energy resolution. The effect of the granularity is studied with a simulation of the AHCAL with 1 x 1 cm"2 cell size, and it has been found that to achieve the best possible energy resolution the semi-digital energy reconstruction is

  20. FASTBUS readout system for the CDF DAQ upgrade

    International Nuclear Information System (INIS)

    Andresen, J.; Areti, H.; Black, D.

    1993-11-01

    The Data Acquisition System (DAQ) at the Collider Detector at Fermilab is currently being upgraded to handle a minimum of 100 events/sec for an aggregate bandwidth that is at least 25 Mbytes/sec. The DAQ System is based on a commercial switching network that has interfaces to VME bus. The modules that readout the front end crates (FASTBUS and RABBIT) have to deliver the data to the VME bus based host adapters of the switch. This paper describes a readout system that has the required bandwidth while keeping the experiment dead time due to the readout to a minimum

  1. The FE-I4 pixel readout integrated circuit

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Sciveres, M., E-mail: mgarcia-sciveres@bl.gov [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Arutinov, D.; Barbero, M. [University of Bonn, Bonn (Germany); Beccherle, R. [Istituto Nazionale di Fisica Nucleare Sezione di Genova, Genova (Italy); Dube, S.; Elledge, D. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Fleury, J. [Laboratoire de l' Accelerateur Lineaire, Orsay (France); Fougeron, D.; Gensolen, F. [Centre de Physique des Particules de Marseille, Marseille (France); Gnani, D. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Gromov, V. [Nationaal Instituut voor Subatomaire Fysica, Amsterdam (Netherlands); Hemperek, T.; Karagounis, M. [University of Bonn, Bonn (Germany); Kluit, R. [Nationaal Instituut voor Subatomaire Fysica, Amsterdam (Netherlands); Kruth, A. [University of Bonn, Bonn (Germany); Mekkaoui, A. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Menouni, M. [Centre de Physique des Particules de Marseille, Marseille (France); Schipper, J.-D. [Nationaal Instituut voor Subatomaire Fysica, Amsterdam (Netherlands)

    2011-04-21

    A new pixel readout integrated circuit denominated FE-I4 is being designed to meet the requirements of ATLAS experiment upgrades. It will be the largest readout IC produced to date for particle physics applications, filling the maximum allowed reticle area. This will significantly reduce the cost of future hybrid pixel detectors. In addition, FE-I4 will have smaller pixels and higher rate capability than the present generation of LHC pixel detectors. Design features are described along with simulation and test results, including low power and high rate readout architecture, mixed signal design strategy, and yield hardening.

  2. CMS and ATLAS honour their suppliers

    CERN Multimedia

    2001-01-01

    In order to motivate the hundreds of companies building their detectors, the CMS and ATLAS collaborations have recently been handing out awards of excellence to their top suppliers. At its second ceremony of this kind, CMS honoured four of its suppliers, while ATLAS for the first time paid tribute to two of its contractors. The atmosphere in the Council Chamber was festive rather than formal at the start of CMS week on Monday 5 March. Before embarking upon a long series of seminars and presentations, the Collaboration held its second awards ceremony to honour its top suppliers. By paying tribute to the exceptional efforts of certain suppliers, the Collaboration's aim is to motivate all the firms, some 500 in total, taking part in the experiment's construction. The CMS Awards panel thus singles out contractors who have not only provided full satisfaction in terms of compliance with specifications, quality and deadlines, but have in addition provided original solutions to delicate problems. Four firms came away...

  3. CMS rewards eight of its suppliers

    CERN Multimedia

    2002-01-01

    At the third awards ceremony to honour its top suppliers, the CMS collaboration presented awards to eight firms. Seven of them are involved in the manufacture of the magnet. The winners of the third CMS suppliers' awards visit the assembly site for the detector. Unsurprisingly, the CMS magnet was once again in the limelight at the third awards ceremony in honour of the collaboration's top suppliers. 'Unsurprisingly', because this magnet, which must produce an intense field of 4 Tesla inside an enormous volume (12 metres in diameter and 13 metres in length) is the detector's key component. As a result, many firms are involved in its construction. The CMS suppliers' awards are an annual event aimed at rewarding the exceptional efforts of certain companies. Firms are only eligible once they have delivered at least 50% of their supplies. This year, the collaboration honoured eight firms at a ceremony held on Monday 4 March in the main auditorium. Seven of th...

  4. Monte Carlo Production Management at CMS

    CERN Document Server

    Boudoul, G.; Pol, A; Srimanobhas, P; Vlimant, J R; Franzoni, Giovanni

    2015-01-01

    The analysis of the LHC data at the Compact Muon Solenoid (CMS) experiment requires the production of a large number of simulated events.During the runI of LHC (2010-2012), CMS has produced over 12 Billion simulated events,organized in approximately sixty different campaigns each emulating specific detector conditions and LHC running conditions (pile up).In order toaggregate the information needed for the configuration and prioritization of the events production,assure the book-keeping and of all the processing requests placed by the physics analysis groups,and to interface with the CMS production infrastructure,the web-based service Monte Carlo Management (McM) has been developed and put in production in 2012.McM is based on recent server infrastructure technology (CherryPy + java) and relies on a CouchDB database back-end.This contribution will coverthe one and half year of operational experience managing samples of simulated events for CMS,the evolution of its functionalitiesand the extension of its capabi...

  5. FAIR: A new fast trigger and readout bus system

    International Nuclear Information System (INIS)

    Ordine, A.; Boiano, A.; Zaghi, A.

    1998-01-01

    FAIR (FAst Intercrate Readout) is a synchronous ECL bus system dedicated to readout. It is based on a new trigger and readout hardware level protocol and on a new control system that learns how to setup and control modules. The hardware protocol along with the data structure allow both readout and event building at the same time at the rate of 22 ns/longword (1.44 Gbit/s) without the need of CPUs. It performs trigger management and full pipelining by using a multilevel FIFO structure. FAIR provides for a multi-crate front-end environment and uses an embedded serial network to accomplish front-end control and setup. The data transfer measured performances and the control system are presented in some detail

  6. A reconfigurable image tube using an external electronic image readout

    Science.gov (United States)

    Lapington, J. S.; Howorth, J. R.; Milnes, J. S.

    2005-08-01

    We have designed and built a sealed tube microchannel plate (MCP) intensifier for optical/NUV photon counting applications suitable for 18, 25 and 40 mm diameter formats. The intensifier uses an electronic image readout to provide direct conversion of event position into electronic signals, without the drawbacks associated with phosphor screens and subsequent optical detection. The Image Charge technique is used to remove the readout from the intensifier vacuum enclosure, obviating the requirement for additional electrical vacuum feedthroughs and for the readout pattern to be UHV compatible. The charge signal from an MCP intensifier is capacitively coupled via a thin dielectric vacuum window to the electronic image readout, which is external to the sealed intensifier tube. The readout pattern is a separate item held in proximity to the dielectric window and can be easily detached, making the system easily reconfigurable. Since the readout pattern detects induced charge and is external to the tube, it can be constructed as a multilayer, eliminating the requirement for narrow insulator gaps and allowing it to be constructed using standard PCB manufacturing tolerances. We describe two readout patterns, the tetra wedge anode (TWA), an optimized 4 electrode device similar to the wedge and strip anode (WSA) but with a factor 2 improvement in resolution, and an 8 channel high speed 50 ohm device, both manufactured as multilayer PCBs. We present results of the detector imaging performance, image resolution, linearity and stability, and discuss the development of an integrated readout and electronics device based on these designs.

  7. Automating the CMS DAQ

    International Nuclear Information System (INIS)

    Bauer, G; Darlea, G-L; Gomez-Ceballos, G; Bawej, T; Chaze, O; Coarasa, J A; Deldicque, C; Dobson, M; Dupont, A; Gigi, D; Glege, F; Gomez-Reino, R; Hartl, C; Hegeman, J; Masetti, L; Behrens, U; Branson, J; Cittolin, S; Holzner, A; Erhan, S

    2014-01-01

    We present the automation mechanisms that have been added to the Data Acquisition and Run Control systems of the Compact Muon Solenoid (CMS) experiment during Run 1 of the LHC, ranging from the automation of routine tasks to automatic error recovery and context-sensitive guidance to the operator. These mechanisms helped CMS to maintain a data taking efficiency above 90% and to even improve it to 95% towards the end of Run 1, despite an increase in the occurrence of single-event upsets in sub-detector electronics at high LHC luminosity.

  8. The CMS "Higgs Boson Goose Game" Poster

    CERN Multimedia

    Davis, Siona Ruth

    Building and operating the CMS Detector is a complicated endeavour! Now, more than 20 years after the detector was conceived, the CMS Bologna group proposes to follow the steps of this challenging project by playing "The Higgs Boson Goose Game", illustrating CMS activities and goals. The concept of the game is inspired by the traditional "Game of the Goose". The underlying idea is that the progress of building and operating a detector at the LHC is similar to the progress of the pawns on the game board: it is fast at times, bringing rewards and satisfaction, while sometimes unexpected problems cause delays or even a step back requiring CMS scientists to use all of their skill and creativity to devise new solutions.

  9. CMS releases new batch of LHC open data

    CERN Document Server

    Achintya Rao

    2016-01-01

    CMS makes 300 TB of high-quality data from the LHC available to the public through the CERN Open Data Portal.   A CMS collision event as seen in the built-in event display on the CERN Open Data Portal (Image: CERN) The CMS collaboration has made 300 TB of high-quality data from the LHC available to the public through the CERN Open Data Portal. The collision data come in two types: The so-called “primary datasets” are in the same format used by the CMS Collaboration to perform research. The “derived datasets” on the other hand require a lot less computing power and can be readily analysed by university or even high-school students. Notably, CMS is also providing the simulated data generated with the same software version that should be used to analyse the primary datasets. Simulations play a crucial role in particle-physics research and CMS is also making available the protocols for generating the simulations that are provided. The data release is accompanie...

  10. Readiness of CMS simulation towards LHC startup

    International Nuclear Information System (INIS)

    Banerjee, S

    2008-01-01

    The CMS experiment has used detector simulation software in its conceptual as well as technical design. With the detector construction near its completion, the role of simulation has changed toward understanding collision data to be collected by CMS in near future. CMS simulation software is becoming a data driven, realistic and accurate Monte Carlo programme. The software architecture is described with some detail of the framework as well as detector specific components. Performance issues are discussed as well

  11. Imaging achievements with the Vernier readout

    CERN Document Server

    Lapington, J S; Worth, L B C; Tandy, J A

    2002-01-01

    We describe the Vernier anode, a high resolution and charge division image readout for microchannel plate detectors. It comprises a planar structure of insulated electrodes deposited on an insulating substrate. The charge cloud from an event is divided amongst all nine electrodes and the charge ratio uniquely determines the two-dimensional position coordinate of the charge centroid. We discuss the design of the anode pattern and describe the advantages offered by this readout. The cyclic variation of the electrode structure allows the image resolution to exceed the charge measurement resolution and enables the entire active area of the readout to be utilized. In addition, fixed pattern noise is greatly reduced. We present results demonstrating the position resolution and image linearity. A position resolution of 10 mu m FWHM is demonstrated and the overall imaging performance is shown to be limited by the microchannel plate pore spacing. We present measurements of the image distortions and describe techniques...

  12. The NA60 experiment readout architecture

    CERN Document Server

    Floris, M; Usai, G L; David, A; Rosinsky, P; Ohnishi, H

    2004-01-01

    The NA60 experiment was designed to identify signatures of a new state of matter, the Quark Gluon Plasma, in heavy-ion collisions at the CERN Super Proton Synchroton. The apparatus is composed of four main detectors: a muon spectrometer (MS), a zero degree calorimeter (ZDC), a silicon vertex telescope (VT), and a silicon microstrip beam tracker (BT). The readout of the whole experiment is based on a PCI architecture. The basic unit is a general purpose PCI card, interfaced to the different subdetectors via custom mezzanine cards. This allowed us to successfully implement several completely different readout protocols (from the VME like protocol of the MS to the custom protocol of the pixel telescope). The system was fully tested with proton and ion beams, and several million events were collected in 2002 and 2003. This paper presents the readout architecture of NA60, with particular emphasis on the PCI layer common to all the subdetectors. (16 refs).

  13. LHCb: A new Readout Control system for the LHCb Upgrade

    CERN Multimedia

    Alessio, F

    2012-01-01

    The LHCb experiment has proposed an upgrade towards a full 40 MHz readout system in order to run between five and ten times its initial design luminosity. The entire readout architecture will be upgraded in order to cope with higher sub-detector occupancies, higher rate and higher network load. In this paper, we describe the architecture, functionalities and the first hardware implementation of a new Readout Control system for the LHCb upgrade. The system is based on FPGAs and bi-directional links for the control of the entire readout architecture. First results on the validation of the system are also given.

  14. Multi-Anode Photomultplier (MAPMT) readout for High Granularity Calorimeters

    CERN Document Server

    Mkrtchyan, Tigran; The ATLAS collaboration

    2017-01-01

    Hadron calorimeter high performance in jet sub-structure measurements can be achieved for objects with $p_{T}$ greater than 1 TeV if the readout geometry is finely segmented in $\\Delta\\eta \\times \\Delta\\phi$. A feasibility study to increase the readout granularity of TileCal, the central hadron calorimeter of the ATLAS detector, is presented. We show a preliminary study exploring the possibility to increase by a factor 4 the present readout granularity of the inner layer cells of TileCal (0.1->0.025 in $\\Delta\\eta$) and to split into two layers the intermediate section of TileCal. The proposed solution is designed to cope with mechanical and readout bandwidth and power constraints. Assuming that the mechanics of the Tile modules cannot be changed, Multi-Anode PMTs with same boundary geometry of the present single-anode PMTs are considered to readout WLS bers, ideally one per pixel, carrying the signals from the individual scintillating tiles of each detector cells. The discussed challenges of the design are: ...

  15. A readout buffer prototype for ATLAS high-level triggers

    CERN Document Server

    Calvet, D; Huet, M; Le Dû, P; Mandjavidze, I D; Mur, M

    2001-01-01

    Readout buffers are critical components in the dataflow chain of the ATLAS trigger/data-acquisition system. At up to 75 kHz, after each Level-1 trigger accept signal, these devices receive and store digitized data from groups of front-end electronic channels. Several readout buffers are grouped to form a readout buffer complex that acts as a data server for the high-level trigger selection algorithms and for the final data-collection system. This paper describes a functional prototype of a readout buffer based on a custom-made PCI mezzanine card that is designed to accept input data at up to 160 MB /s, to store up to 8 MB of data, and to distribute data chunks at the desired request rate. We describe the hardware of the card that is based on an Intel 1960 processor and complex programmable logic devices. We present the integration of several of these cards in a readout buffer complex. We measure various performance figures and discuss to which extent these can fulfil ATLAS needs. (5 refs).

  16. Study for the LHCb upgrade read-out board

    CERN Document Server

    Cachemiche, J P; Hachon, F; Le Gac, R; Marin, F; 10.1088/1748-0221/5/12/C12036

    2010-01-01

    The LHCb experiment envisages to upgrade its readout electronics in order to increase the readout rate from 1 MHz to 40 MHz. This electronics upgrade is very challenging, since readout boards will have to handle a higher number of serial links with an increased bandwidth. In addition, the new communication protocol (GBT) developed by the CERN micro-electronics group mixes data acquisition, slow control and clock distribution on the same link. To explore the feasibility of such a readout system, elementary building blocks have been studied. Their goals are multiple: understand signal integrity when using highly integrated high speed serial links running at 8 - 10 Gbits/s; test the implementation of the GBT protocol within FPGAs; understand advantages and limitations of commercial standard with a predefined interconnection topology; validate ideas on how to control easily such a system. We designed two boards compliant with the xTCA standard which meets an increasing interest in the physics community. The first...

  17. Detector Alignment Studies for the CMS Experiment

    CERN Document Server

    Lampén, Tapio

    2007-01-01

    This thesis presen ts studies related to trac k-based alignmen t for the future CMS exp erimen t at CERN. Excellen t geometric alignmen t is crucial to fully bene t from the outstanding resolution of individual sensors. The large num ber of sensors mak es it dicult in CMS to utilize computationally demanding alignmen t algorithms. A computationally ligh t alignmen t algorithm, called the Hits and Impact Points algorithm (HIP), is dev elop ed and studied. It is based on minimization of the hit residuals. It can be applied to individual sensors or to comp osite objects. All six alignmen t parameters (three translations and three rotations), or their subgroup can be considered. The algorithm is exp ected to be particularly suitable for the alignmen t of the innermost part of CMS, the pixel detector, during its early operation, but can be easily utilized to align other parts of CMS also. The HIP algorithm is applied to sim ulated CMS data and real data measured with a test-b eam setup. The sim ulation studies dem...

  18. 42 CFR 482.74 - Condition of participation: Notification to CMS.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition of participation: Notification to CMS... participation: Notification to CMS. (a) A transplant center must notify CMS immediately of any significant... conditions of participation. Instances in which CMS should receive information for follow up, as appropriate...

  19. The CMS Electromagnetic Calorimeter: Construction, Commissioning and Calibration

    CERN Document Server

    ORIMOTO,Toyoko J.

    2009-01-01

    The Compact Muon Solenoid (CMS) detector at the Large Hadron Colider (LHC) is ready for first collisions. The Electromagnetic Calorimeter (ECAL) of CMS, a high resolution detector comprised of nearly 76000 lead tungstate crystals, will play a crucial role in the coming physics searches undertaken by CMS. The design and performance of the CMS ECAL with test beams, cosmic rays, and first single beam data will be presented. In addition, the status of the calorimeter and plans for calibration with first collisions will be discussed. European Physical Society Europhysics Conference on High Energy Physics July 16-22, 2009 Krakow, Poland ∗Speaker.

  20. Study on two-dimensional induced signal readout of MRPC

    International Nuclear Information System (INIS)

    Wu Yucheng; Yue Qian; Li Yuanjing; Ye Jin; Cheng Jianping; Wang Yi; Li Jin

    2012-01-01

    A kind of two-dimensional readout electrode structure for the induced signal readout of MRPC has been studied in both simulation and experiments. Several MRPC prototypes are produced and a series of test experiments have been done to compare with the result of simulation, in order to verify the simulation model. The experiment results are in good agreement with those of simulation. This method will be used to design the two-dimensional signal readout mode of MRPC in the future work.