Sample records for closely monitored equipment

  1. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  2. Coal ash monitoring equipment

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, C G; Wormald, M R

    1978-10-02

    The monitoring equipment is used to determine the remainder from combustion (ash slack) of coal in wagons designed for power stations. Next to the rails, a neutron source (252 Cf, 241 Am/Be) is situated, which irradiates the coal with neutrons at a known dose, which produces the reaction 27 Al (n ..gamma..) Al 28. The aluminium content is a measure of the remainder. The 1.78 MeV energy is measured downstream of the rail with a detector. The neutron source can only act in the working position of a loaded wagon.

  3. Operation monitor for plant equipment

    International Nuclear Information System (INIS)

    Kondo, Tetsufumi; Kanemoto, Shigeru.

    1991-01-01

    In a nuclear power plant, states of each of equipment in the plant are monitored accurately even under such a operation condition that the power is changed. That is, the fundamental idea is based on a model comparison method. A deviation between an output signal upon normal plant state obtained in a forecasting model device and that of the objective equipment in the plant are compared with a predetermined value. The result of the comparison is inputted to an alarm device to alarm the abnormality of the states of the equipment to an operator. The device of the present invention thus constituted can monitor the abnormality of the operation of equipment accurately even under such a condition that a power level fluctuates. As a result, it can remarkably contribute to mitigate operator's monitoring operation under the condition such as during load following operation. (I.S.)

  4. Performance monitoring of safeguards equipment

    International Nuclear Information System (INIS)

    Sirisena, K.; Peltoranta, M.; Goussarov, V.; Vodrazka, P.

    1999-01-01

    SGTCS is responsible for monitoring and reporting the performance of the SG equipment. Performance monitoring (PM) has been implemented in most important safeguards equipment operating unattended in nuclear facilities. Inspectors acquire equipment performance data in facilities. After inspection, the data package is submitted to SGTCS for processing and analysis. The performance data is used for identification of systems or components, which should be changed in the field and for identification of modules which, should be diagnosed at HQ in order to determine the cause of failure. Moreover, the performance data is used for preventive maintenance and spares distribution planning, and to provide statistics for official reports and management decision making. An important part of the performance monitoring is reporting. Equipment performance reports contain information about equipment inventory, utilization, failure types, failure distribution, and reliability. Trends in performance are given in graphical form in cases, where past data is available. Reliability estimates such as expected times between failures are provided. The automated reporting tools are obtainable through EMIS database application. (author)

  5. Improving the hygienic design of closed equipment

    DEFF Research Database (Denmark)

    Friis, Alan; Jensen, Bo Boye Busk

    2005-01-01

    Maintenance of proper hygiene in closed process equipment is in many ways a complex task. The interaction between the physical design and the nature of fluid flow is of main concern. During cleaning the main performance of the flow is to bring cleaning agents in the right doses to all parts of th...... computational fluid dynamics models to be able to predict the cleaning efficiency in especially complex parts of process plants has excellent potentials for desktop improvements and computer pre-validation of the hygienic performance of process plants....

  6. Data Center Equipment Location and Monitoring System

    DEFF Research Database (Denmark)

    2013-01-01

    Abstract: Data center equipment location systems include hardware and software to provide information on the location, monitoring, and security of servers and other equipment in equipment racks. The systems provide a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to an equipment rack controller on the equipment rack. The equipment rack controllers link to a central control computer that provides an operator ...

  7. An on-line monitoring system for navigation equipment

    Science.gov (United States)

    Wang, Bo; Yang, Ping; Liu, Jing; Yang, Zhengbo; Liang, Fei

    2017-10-01

    Civil air navigation equipment is the most important infrastructure of Civil Aviation, which is closely related to flight safety. In addition to regular flight inspection, navigation equipment's patrol measuring, maintenance measuring, running measuring under special weather conditions are the important means of ensuring aviation flight safety. According to the safety maintenance requirements of Civil Aviation Air Traffic Control navigation equipment, this paper developed one on-line monitoring system with independent intellectual property rights for navigation equipment, the system breakthroughs the key technologies of measuring navigation equipment on-line including Instrument Landing System (ILS) and VHF Omni-directional Range (VOR), which also meets the requirements of navigation equipment ground measurement set by the ICAO DOC 8071, it provides technical means of the ground on-line measurement for navigation equipment, improves the safety of navigation equipment operation, and reduces the impact of measuring navigation equipment on airport operation.

  8. Data center equipment location and monitoring system

    DEFF Research Database (Denmark)

    2011-01-01

    A data center equipment location system includes both hardware and software to provide for location, monitoring, security and identification of servers and other equipment in equipment racks. The system provides a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to a equipment rack controller on the equipment rack. The equipment rack controllers then link over a local area network to a central control computer. The central control computer provides an operator interface......, and runs a software application program that communicates with the equipment rack controllers. The software application program of the central control computer stores IDs of the equipment rack controllers and each of its connected electronic ID tags in a database.; The software application program...

  9. Noise control of radiological monitoring equipment

    International Nuclear Information System (INIS)

    Rubick, R.D.; Stevens, W.W.; Burke, L.L.

    1998-01-01

    Although vacuum pumps on continuous air monitors (CAMs) do not produce noise levels above regulatory limits, engineering controls were used to establish a safer work environment. Operations performed in areas where CAMs are located are highly specialized and require precision work when handling nuclear materials, heavy metals, and inert gases. Traditional methods for controlling noise such as enclosing or isolating the source and the use of personal protection equipment were evaluated. An innovative solution was found by retrofitting CAMs with air powered multistage ejectors pumps. By allowing the air to expand in several chambers to create a vacuum, one can eliminate the noise hazard altogether. In facilities with adequate pressurized air, use of these improved ejector pumps may be a cost-effective replacement for noisy vacuum pumps. A workplace designed or engineered with noise levels as low as possible or as close to background adds to increased concentration, attention to detail, and increased production

  10. Equipment abnormality monitoring method and device therefor

    International Nuclear Information System (INIS)

    Yamada, Izumi; Asakura, Yamato; Uemura, Hiroshi; Uchida, Shunsuke; Oyamada, Osamu; Oyobe, Koji.

    1994-01-01

    In the present invention, it is judged whether the operation state of equipments used in a plant are normal or not by using learning performances. That is, a plurality of monitoring parameters are measured for an equipment. Previously determined monitoring parameters are extracted. A leaning mode or a monitoring mode is selected. In the leaning mode, based on the values of previously determined monitoring parameters, values of other monitoring parameters during normal states are learned. In the monitoring mode, based on the values of the previously determined monitoring parameters, typical values of other leaned monitoring parameters are outputted. The typical values of other normal monitoring parameters after learning and the values of other parameters at the present time are compared. If the values of the other parameters at the present time are out of normal range, it is judged as abnormal, and the result is alarmed and displayed. (I.S.)

  11. Radio monitoring problems, methods, and equipment

    CERN Document Server

    Rembovsky, Anatoly; Kozmin, Vladimir; Smolskiy, Sergey

    2009-01-01

    Offers a unified approach to fundamental aspects of Automated Radio Monitoring (ARM). This book discusses the development, modeling, design, and manufacture of ARM systems. It provides classification and descriptions of modern high-efficient hardware-software ARM equipment, including the equipment for detection and radio direction-finding.

  12. Automatic monitoring of vibration welding equipment

    Science.gov (United States)

    Spicer, John Patrick; Chakraborty, Debejyo; Wincek, Michael Anthony; Wang, Hui; Abell, Jeffrey A; Bracey, Jennifer; Cai, Wayne W

    2014-10-14

    A vibration welding system includes vibration welding equipment having a welding horn and anvil, a host device, a check station, and a robot. The robot moves the horn and anvil via an arm to the check station. Sensors, e.g., temperature sensors, are positioned with respect to the welding equipment. Additional sensors are positioned with respect to the check station, including a pressure-sensitive array. The host device, which monitors a condition of the welding equipment, measures signals via the sensors positioned with respect to the welding equipment when the horn is actively forming a weld. The robot moves the horn and anvil to the check station, activates the check station sensors at the check station, and determines a condition of the welding equipment by processing the received signals. Acoustic, force, temperature, displacement, amplitude, and/or attitude/gyroscopic sensors may be used.

  13. Dynamic monitoring equipment for earthworks and sub grades

    International Nuclear Information System (INIS)

    Alvarez de Sotomayor, R.

    2013-01-01

    This paper take into account some dynamic auscultation equipment s that currently are available in Spain for compaction quality control on earthworks and sub grades. Closed to the equipment description, a deformation modulus calculus approximation has been developed for each of them. A standards checking has been made from national and European point of view. some important research works that have been developed in our country about dynamic monitoring equipment s for quality control in earthworks has been mentioned. In addition to this, some variables are analyzed which have an influence on deformation modulus calculi and a possibility for comparing the equipment modulus calculated with a reference laboratory test has been offered. (Author) 18 refs.

  14. Composition and fundamental requirements of nuclear emergency response monitoring equipment

    International Nuclear Information System (INIS)

    Lai Yongfang; Huang Weiqi; Wang Yonghong

    2009-01-01

    Nuclear emergency monitoring equipment is concrete foundation for accomplishing radiation monitoring in nuclear or radiation accidents. Based on technical report: Generic procedures for monitoring in a nuclear or radiological emergency published by IAEA in 1999, this paper presents the main task and composition of nuclear emergency monitoring briefly, and then the basic equipment and trends of nuclear emergency monitoring equipment is put forward in detail, which is useful to construction and reinforcement of our nuclear emergency monitoring. (authors)

  15. Plant-wide integrated equipment monitoring and analysis system

    International Nuclear Information System (INIS)

    Morimoto, C.N.; Hunter, T.A.; Chiang, S.C.

    2004-01-01

    A nuclear power plant equipment monitoring system monitors plant equipment and reports deteriorating equipment conditions. The more advanced equipment monitoring systems can also provide information for understanding the symptoms and diagnosing the root cause of a problem. Maximizing the equipment availability and minimizing or eliminating consequential damages are the ultimate goals of equipment monitoring systems. GE Integrated Equipment Monitoring System (GEIEMS) is designed as an integrated intelligent monitoring and analysis system for plant-wide application for BWR plants. This approach reduces system maintenance efforts and equipment monitoring costs and provides information for integrated planning. This paper describes GEIEMS and how the current system is being upgraded to meet General Electric's vision for plant-wide decision support. (author)

  16. An introduction to closed field sputtering (CFS) equipment

    International Nuclear Information System (INIS)

    Sugden, G.B.

    1979-01-01

    Ways have been sought to develop the vacuum sputtering process to reduce the source material temperature and to increase the deposition rate. A new industrial plating method superior to vacuum evaporation and electroplating has emerged. In this 'closed field sputtering' processes an electric field is applied between a coaxial anode and cathode and a magnetic field applied orthogonally to the electric field. Providing the flux density of the magnetic field is above a critical value no electrons flow to the anode but move along the magnetic lines around the cathode, enclosed in the magnetic field. A high density electron cloud with high ionization probability is therefore maintained. Low temperature sputtering can be attained due to very low energy loss of electrons at the anode. A pressure of about (2-5) x 10(-4) torr is used. High power can be applied to the equipment without producing much heat. It enables a large number of plastic parts to be coated with almost any nonmagnetic metal and alloys of metals on a commercial basis. It is also possible to produce coatings of oxides. nitrides and carbides of metals. The method of operation and a description of the equipment are given. Applications include car exteriors, household appliances, furniture toys and the electronics industry. (UK)

  17. Research on Health State Perception Algorithm of Mining Equipment Based on Frequency Closeness

    Directory of Open Access Journals (Sweden)

    Gang Wang

    2014-06-01

    Full Text Available The health state perception of mining equipment is intended to have an online real- time knowledge and analysis of the running conditions of large mining equipments. Due to its unknown failure mode, a challenge was raised to the traditional fault diagnosis of mining equipments. A health state perception algorithm of mining equipment was introduced in this paper, and through continuous sampling of the machine vibration data, the time-series data set was set up; subsequently, the mode set based on the frequency closeness was constructed by the d neighborhood method combined with the TSDM algorithm, thus the forecast method on the basis of the dual mode set was eventually formed. In the calculation of the frequency closeness, the Goertzel algorithm was introduced to effectively decrease the computation amount. It was indicated through the simulation test on the vibration data of the drum shaft base that the health state of the device could be effectively distinguished. The algorithm has been successfully applied to equipment monitoring in the Huoer Xinhe Coal Mine of Shanxi Coal Imp&Exp. Group Co., Ltd.

  18. Tritium monitoring equipments for animal experiment facilities

    International Nuclear Information System (INIS)

    Sato, Hiroo

    1980-01-01

    Animal experiment facilities using tritium are described with reference to laws and regulations concerning radiological safety. Usual breeding facilities and surrounding conditions at non-radioactive animal experiments are summarized on feasible and effective designs of tritium monitors. Characteristics and desirable arrangements of various kinds of tritium monitors such as ionization chambers, proportional counters and liquid scintillation detectors are discussed from the standpoint of monitoring for room, glove-box, stack, liquid waste and personnel. (J.P.N.)

  19. Safety valve opening and closing operation monitor

    International Nuclear Information System (INIS)

    Kodama, Kunio; Takeshima, Ikuo; Takahashi, Kiyokazu.

    1981-01-01

    Purpose: To enable the detection of the closing of a safety valve when the internal pressure in a BWR type reactor is a value which will close the safety valve, by inputting signals from a pressure detecting device mounted directly at a reactor vessel and a safety valve discharge pressure detecting device to an AND logic circuit. Constitution: A safety valve monitor is formed of a pressure switch mounted at a reactor pressure vessel, a pressure switch mounted at the exhaust pipe of the escape safety valve and a logic circuit and the lide. When the input pressure of the safety valve is raised so that the valve and the pressure switch mounted at the exhaust pipe are operated, an alarm is indicated, and the operation of the pressure switch mounted at a pressure vessel is eliminated. If the safety valve is not reclosed when the vessel pressure is decreased lower than the pressure at which it is to be reclosed after the safety valve is operated, an alarm is generated by the logic circuit since both the pressure switches are operated. (Sekiya, K.)

  20. Leakage monitoring equipment of fuel element by delayed neutron method

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Shulan; Zhang Shuheng

    1999-01-01

    Based on monitoring results of delayed neutrons from reactor first circle water, the leakage of reactor fuel elements is monitored. A monitoring equipment consisted of an array of 3 He proportional counter tubes with 75 s delay has been developed. The neutron detection efficiency of 6.1% is obtained

  1. Practical remote monitoring using COTS equipment

    International Nuclear Information System (INIS)

    Kadner, S.; White, R.M.; Pepper, S.

    1999-01-01

    It has been clear for some time that the gap between the international nonproliferation verification agenda and the available financial means can only be bridged by adoption of remote monitoring technologies in specific safeguards applications. Past technology development efforts have focused largely on sensor networking and dedicated communications services to link the inspector to the Safeguards instruments using the traditional verification paradigm. Today we have several Commercial Off The Shelf (COTS) sensor networking alternatives that are viable for Safeguards and it has been found that no single communication service can be uniformly deployed in all verification scenarios. While sensor networking is an important element of remote monitoring technology, it does not by itself provide a viable remote monitoring capability. This paper discusses several lessons have been learned from the IAEA's remote monitoring installation in Pelindaba, South Africa and how those lessons have been extended to near-term installations in Japan and Canada. Key among those lessons is that the traditional verification paradigm cannot, and should not, be carried forward into the remote monitoring regime and that the primary technology component of the successful remote monitoring installation is the Server, which processes, filters, categorizes, and otherwise acts on the sensor inputs to dramatically reduce the volume and increase the information -density of data that is transferred remotely using indigenous communication infrastructures. (author)

  2. SOLUTION FOR AN EQUIPMENT OF RAILWAY BRIDGE MONITORING

    Directory of Open Access Journals (Sweden)

    Liviu Mihai SIMA

    2009-11-01

    Full Text Available This paper presents a solution for the railway bridges monitoring based on the use of already existing equipments in the railway installations and some new equipments based on photo-elements, as well. This kind of equipments can function in continue and discontinuous regime, means of them tracking down if the bridge piles suffered movements by different reasons. This aspect can put in danger the safety of the circulation on that bridge.

  3. Integrated reliability condition monitoring and maintenance of equipment

    CERN Document Server

    Osarenren, John

    2015-01-01

    Consider a Viable and Cost-Effective Platform for the Industries of the Future (IOF) Benefit from improved safety, performance, and product deliveries to your customers. Achieve a higher rate of equipment availability, performance, product quality, and reliability. Integrated Reliability: Condition Monitoring and Maintenance of Equipment incorporates reliable engineering and mathematical modeling to help you move toward sustainable development in reliability condition monitoring and maintenance. This text introduces a cost-effective integrated reliability growth monitor, integrated reliability degradation monitor, technological inheritance coefficient sensors, and a maintenance tool that supplies real-time information for predicting and preventing potential failures of manufacturing processes and equipment. The author highlights five key elements that are essential to any improvement program: improving overall equipment and part effectiveness, quality, and reliability; improving process performance with maint...

  4. Perry Nuclear Power Plant Area/Equipment Temperature Monitoring Program

    International Nuclear Information System (INIS)

    McGuire, L.L.

    1991-01-01

    The Perry Nuclear Power Plant Area/Equipment Temperature Monitoring Program serves two purposes. The first is to track temperature trends during normal plant operation in areas where suspected deviations from established environmental profiles exist. This includes the use of Resistance Temperature Detectors, Recorders, and Temperature Dots for evaluation of equipment qualified life for comparison with tested parameters and the established Environmental Design Profile. It also may be used to determine the location and duration of steam leaks for effect on equipment qualified life. The second purpose of this program is to aid HVAC design engineers in determining the source of heat outside anticipated design parameters. Resistance Temperature Detectors, Recorders, and Temperature Dots are also used for this application but the results may include design changes to eliminate the excess heat or provide qualified equipment (cable) to withstand the elevated temperature, splitting of environmental zones to capture accurate temperature parameters, or continued environmental monitoring for evaluation of equipment located in hot spots

  5. Internal dosimetry monitoring equipment: Present and future

    International Nuclear Information System (INIS)

    Selby, J.; Carbaugh, E.H.; Lynch, T.P.; Strom, D.J.; Lardy, M.M.

    1993-09-01

    We have attempted to characterize the current and future status of in vivo and in vitro measurement programs coupled with the associated radioanalytical methods and workplace monitoring. Developments in these areas must be carefully integrated by internal dosimetrists, radiochemists and field health physicists. Their goal should be uniform improvement rather than to focus on one specific area (e.g., dose modeling) to the neglect of other areas where the measurement capabilities are substantially less sophisticated and, therefore, the potential source of error is greatest

  6. BH2201 type leakage monitoring equipment of reactor fuel elements

    International Nuclear Information System (INIS)

    Ji Changsong; Dai Zhude; Xie Liangnian; Zhang Shulan; Zhang Shuheng

    1999-01-01

    A high-sensitive equipment monitoring leakage of the reactor fuel elements has been developed. The delayed neutrons emitted from fission product-pioneer nucleus are monitored in the 1st circle water. An array of 3 He proportional counter tubes is designed as a neutron detector for delayed neutrons, the detection geometry of which is near to 4π. In order to reduce the influence of interference factors the monitoring of fission product is carried out with 75s delay. The 87 Br delayed neutron pioneer nucleus is chosen as a monitoring object. The neutron detection efficiency of the developed equipment is 6.1%, which is 3 times higher than one of all available advanced equipment of the same function both at home and abroad

  7. Non-invasive system for monitoring of the manufacturing equipment

    Science.gov (United States)

    Mazăre, A. G.; Belu, N.; Ionescu, L. M.; Rachieru, N.; Misztal, A.

    2017-08-01

    The automotive industry is one of the most important industries in the world that concerns the economy and the world culture. High demand has resulted in increasing of the pressure on the production lines. In conclusion, it is required more careful in monitoring of the production equipment not only for maintenance but also for staff safety and to increase the quality of production. In this paper, we propose a solution for non-invasive monitoring of the industrial equipment operation by measuring the current consumption on energy supply lines. Thus, it is determined the utilization schedule of the equipment and operation mode. Based on these measurements, it’s built an activity report for that equipment, available to the quality management and maintenance team. The solution consists of the current measuring equipment, with self-harvesting capabilities and radio transceiver, and an embedded system which run a server. The current measuring equipment will transmit data about consumption of each energy supply network line where is placed the industrial equipment. So, we have an internal measuring radio network. The embedded system will collect data for the equipment and put in a local data base and it will provide via an intranet application. The entire system not requires any supplementary energy supply and interventions in the factory infrastructure. It is experimented in a company from the automotive industries.

  8. Application of Equipment Monitoring Technology in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kang, H. T.; Lee, J. K.; Lee, K. D.; Jo, S. H.

    2012-01-01

    The major goal of nuclear power industries during the past 10 years is to increase reliability and utility capacity factor. As the capacitor factor, however, crept upward. it became harder to attain next percentage of improvement. Therefore other innovative technologies are required. By the technologies applied to the fossil power plants, equipment health monitoring was performed on equipment to maintain it in operable condition and contributed on improving their reliability a lot. But the equipment monitoring may be limited to the observation of current system states in nuclear power plant. Monitoring of current system states is being augmented with prediction of future operating states and predictive diagnosis of future failure states. Such predictive diagnosis is motivated by the need for nuclear power plants to optimize equipment performance and reduce costs and unscheduled downtime. This paper reviews the application of techniques that focus on improving reliability in nuclear power plant by monitoring and predicting equipment health and suggests how possible to support on-line monitoring

  9. Progress report of the critical equipment monitoring system

    International Nuclear Information System (INIS)

    Pantis, M.J.

    1984-01-01

    The Philadelphia Electric Company has contracted with Energy Data Systems to develop a Critical Equipment Monitoring System for its Peach Bottom Nuclear Plant. This computerized system is designed to acquire and maintain accurate and timely status information on plant equipment. It will provide auditable record of plant and equipment transactions. Positive equipment identification and location will be provided. Errors in complex logical checking will be minimized. This system should reduce operator loading and improve operator communicatin with the plant personnel. Phase I of this system was installed at Peach Bottom Nuclear Station May 1982. It provides the necessary hardware and software to do check-off lists on critical plant systems. This paper describes some of the start-up and operational problems encountered

  10. Dynamic monitoring equipment for earthworks and sub grades; Euipos de auscultacion dinamica para obras de tierra

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez de Sotomayor, R.

    2013-06-01

    This paper take into account some dynamic auscultation equipment s that currently are available in Spain for compaction quality control on earthworks and sub grades. Closed to the equipment description, a deformation modulus calculus approximation has been developed for each of them. A standards checking has been made from national and European point of view. some important research works that have been developed in our country about dynamic monitoring equipment s for quality control in earthworks has been mentioned. In addition to this, some variables are analyzed which have an influence on deformation modulus calculi and a possibility for comparing the equipment modulus calculated with a reference laboratory test has been offered. (Author) 18 refs.

  11. Monitoring equipment environment during nuclear plant operation at Salem and Hope Creek generating stations

    International Nuclear Information System (INIS)

    Blum, A.; Smith, R.J.

    1991-01-01

    Monitoring of environmental parameters has become a significant issue for operating nuclear power plants. While the long-term benefits of plant life extension programs are being pursued with comprehensive environmental monitoring programs, the potential effect of local hot spots at various plant locations needs to be evaluated for its effect on equipment degradation and shortening of equipment qualified life. A significant benefit can be experienced from temperature monitoring when a margin exists between the design versus actual operating temperature. This margin can be translated into longer equipment qualified life and significant reduction in maintenance activities. At PSE and G, the immediate need for monitoring environmental parameters is being accomplished via the use of a Logic Beach Bitlogger. The Bitlogger is a portable data loggings system consisting of a system base, input modules and a communication software package. Thermocouples are installed on selected electrical equipment and cables are run from the thermocouples to the input module of the Bitlogger. Temperature readings are taken at selected intervals, stored in memory, and downloaded periodically to a PC software program, i.e., Lotus. The data is formatted into tabular or graphical documents. Because of their versatility, Bitloggers are being used differently at the authors Nuclear facility. At the Salem Station (2 Units-4 loop Westinghouse PWR), a battery powered, fully portable, calibrated Bitlogger is located in an accessible area inside Containment where it monitors the temperature of various electrical equipment within the Pressurizer Enclosure. It is planned that close monitoring of the local hot spot temperatures in this area will allow them to adjust and reconcile the environmental qualification of the equipment

  12. A Digital Power Quality Monitoring Equipment Designed for Digital Substation

    Science.gov (United States)

    Li, Wei; Wang, Xin; Geng, Jiewen

    2018-01-01

    Taking into account both current status and development trend of digital substation, this paper proposed a design of a new multi-channelled digital power quality monitoring equipment with high compatibility. The overall functional structure, hardware architecture, software architecture, interface architecture and some key techniques such as IEC 61850 modelling of transient event and harmonic measurement method under the condition of non-synchronous sampling are described in this paper.

  13. Design for a Remote Monitoring Equipment of Krypton-85

    Institute of Scientific and Technical Information of China (English)

    LUXue-sheng; LIUGuo-rong; YEFeng; JINHui-min; TANGPei-jia

    2003-01-01

    A prototype equipment for monitoring Krypton-85 in situ is designed and set up. A series of relevant software is also developed for remote control, data acquirement and data analysis. Weight of the system is about 300 kg, which is composed of NaI(T1) detector, digi DART, Marillin measurement container and lead shield. The whole system is placed on a homemade go-cart.

  14. Data acquisition, remote control and equipment monitoring for ISOLDE RILIS

    Energy Technology Data Exchange (ETDEWEB)

    Rossel, R.E., E-mail: ralf.erik.rossel@cern.ch [CERN, Geneva (Switzerland); Institut für Physik, Johannes Gutenberg-Universität, Mainz (Germany); Hochschule RheinMain, Fachbereich Design Informatik Medien, Wiesbaden (Germany); Fedosseev, V.N.; Marsh, B.A. [CERN, Geneva (Switzerland); Richter, D. [Hochschule RheinMain, Fachbereich Design Informatik Medien, Wiesbaden (Germany); Rothe, S. [CERN, Geneva (Switzerland); Institut für Physik, Johannes Gutenberg-Universität, Mainz (Germany); Wendt, K.D.A. [Institut für Physik, Johannes Gutenberg-Universität, Mainz (Germany)

    2013-12-15

    Highlights: • The requirements for continuous and automated RILIS operation are outlined. • Laser wavelength, power, beam position and pulse timing are continuously monitored. • A network-extended LabVIEW-based equipment operation framework was developed. • The system serves as a foundation for collaborative laser spectroscopy data acquisition. • Example applications have been successfully tested with ISOLDE experiment setups. -- Abstract: With a steadily increasing on-line operation time up to a record 3000 h in the year 2012, the Resonance Ionization Laser Ion Source (RILIS) is one of the key components of the ISOLDE on-line isotope user facility at CERN. Ion beam production using the RILIS is essential for many experiments due to the unmatched combination of ionization efficiency and selectivity. To meet the reliability requirements the RILIS is currently operated in shift duty for continuous maintenance of crucial laser parameters such as wavelength, power, beam position and timing, as well as ensuring swift intervention in case of an equipment malfunction. A recent overhaul of the RILIS included the installation of new pump lasers, commercial dye lasers and a complementary, fully solid-state titanium:sapphire laser system. The framework of the upgrade also required the setup of a network-extended, LabVIEW-based system for data acquisition, remote control and equipment monitoring, to support RILIS operators as well as ISOLDE users. The system contributes to four key aspects of RILIS operation: equipment monitoring, machine protection, automated self-reliance, and collaborative data acquisition. The overall concept, technologies used, implementation status and recent applications during the 2012 on-line operation period will be presented along with a summary of future developments.

  15. Radiation protection instrumentation. Monitoring equipment. Radioactive aerosols in the environment

    International Nuclear Information System (INIS)

    1996-01-01

    This international standard applies to portable or installed equipment for continuous monitoring of radioactive aerosols in the environment in normal and emergency conditions. Monitoring involves continuous sampling and, where desirable, automatic start of sampling. The document applies particularly to the following assignments: (i) determination of the volume activity of radionuclides in the form of aerosols, either per time unit, along with its time changes, or in the integral form over a longer time period such as 24 h, and measurement of the volume sampled; (ii) triggering a warning alarm signal if the preset volume activity or time integral of the volume activity of aerosols has been exceeded. The document deals with radioactive aerosol monitor design, testing procedures, and documentation. Appended tables refer to the reference and normal testing conditions, tests in normal testing conditions, tests during changes of the affecting quantities, and tests of the air circuit. (P.A.)

  16. Data acquisition, remote control and equipment monitoring for ISOLDE RILIS

    Science.gov (United States)

    Rossel, R. E.; Fedosseev, V. N.; Marsh, B. A.; Richter, D.; Rothe, S.; Wendt, K. D. A.

    2013-12-01

    With a steadily increasing on-line operation time up to a record 3000 h in the year 2012, the Resonance Ionization Laser Ion Source (RILIS) is one of the key components of the ISOLDE on-line isotope user facility at CERN. Ion beam production using the RILIS is essential for many experiments due to the unmatched combination of ionization efficiency and selectivity. To meet the reliability requirements the RILIS is currently operated in shift duty for continuous maintenance of crucial laser parameters such as wavelength, power, beam position and timing, as well as ensuring swift intervention in case of an equipment malfunction. A recent overhaul of the RILIS included the installation of new pump lasers, commercial dye lasers and a complementary, fully solid-state titanium:sapphire laser system. The framework of the upgrade also required the setup of a network-extended, LabVIEW-based system for data acquisition, remote control and equipment monitoring, to support RILIS operators as well as ISOLDE users. The system contributes to four key aspects of RILIS operation: equipment monitoring, machine protection, automated self-reliance, and collaborative data acquisition. The overall concept, technologies used, implementation status and recent applications during the 2012 on-line operation period will be presented along with a summary of future developments.

  17. Expansion of the acceptance program: nitrous oxide scavenging equipment and nitrous oxide trace gas monitoring equipment

    Energy Technology Data Exchange (ETDEWEB)

    1977-10-01

    The Acceptance Program for dental materials and devices and the general guidelines for submission of products have been reported in the Journal (88:615 March 1974). At its April 1977 meeting, the Council included equipment for scavenging and monitoring trace nitrous oxide gas in its Acceptance Program. The Council has established the effective date for classification of products under these two sets of guidelines as one year from the date of publication of this announcement. After that date, classification of a product will be required before promotion or exhibition in Association media.

  18. Long-term monitoring for closed special sites

    International Nuclear Information System (INIS)

    Golchert, N.W.; Sedlet, J.

    1987-01-01

    A methodology is presented for planning and implementing a long-term environmental monitoring program for closed special radioactive waste disposal sites. The steps in the method involve collection of the available background information on the site history, site and area characteristics, waste inventory, pathway analysis, prior monitoring programs, applicable standards, and the legal/regulatory requirements. This information is coupled with factors such as experience, half-life, radionuclide migration rates, and potential hazard to develop a monitoring program. As an example, a site-specific long-term monitoring program is described for the AMAX site using the available information. Sampling techniques and practices for the monitoring program are discussed and techniques and practices expected to be available in the future are considered. 7 references, 2 tables

  19. Safeguards equipment of the future: Integrated monitoring systems and remote monitoring

    International Nuclear Information System (INIS)

    Sonnier, C.S.; Johnson, C.S.

    1994-01-01

    From the beginning, equipment to support IAEA Safeguards could be characterized as that which is used to measure nuclear material, Destructive Assay (DA) and Non Destructive Assay (NDA), and that which is used to provide continuity of knowledge between inspection intervals, Containment ampersand Surveillance (C/S). C/S equipment has often been thought of as Cameras and Seals, with a limited number of monitors being employed as they became available. In recent years, technology has advanced at an extremely rapid rate, and continues to do so. The traditional film cameras are being replaced by video equipment, and fiber optic and electronic seals have come into rather widespread use. Perhaps the most interesting aspect of this evolution, and that which indicates the wave of the future without much question, is the integration of video surveillance and electronic seals with a variety of monitors. This is demonstrated by safeguards systems which are installed in several nuclear facilities in France, Germany, Japan, the UK, the USA, and elsewhere. The terminology of Integrated Monitoring Systems (IMS) has emerged, with the employment of network technology capable of interconnecting all desired elements in a very flexible manner. Also, the technology for transmission of a wide variety of information to off-site locations, termed Remote Monitoring, is in widespread industrial use, requiring very little adaptation for safeguards use. This paper examines the future of the Integrated Monitoring Systems and Remote Monitoring in International Safeguards, including technical and other related factors

  20. Microcomputer network for technological equipment monitoring and control

    International Nuclear Information System (INIS)

    Segec, O.

    1990-01-01

    The properties and purpose are characterized of a microcomputer network developed for monitoring and controlling the nuclear power plant chemistry. In the development, emphasis was put on simplicity of the components, reliability, ease of operation and availability of the components on the domestic market. So far, these criteria are only met by the DIAMO L(S) system equipped with an MH 8080 (Z80) processor. Its assets include simplicity and ruggedness, owing to which it is well suited to heavy-duty performance, whereas its drawbacks comprise a narrow extent of addressable memory and absence of any supporting software. Until now, 5 types of automated stations have been developed and submitted for test operation at the Bohunice V-2 nuclear power plant. Virtually any personal computer can be attached to the network. The system can also be installed in conventional power plants as well as beyond the power generation field. (Z.M.)

  1. Nuclear electronics equipment for control and monitoring panel

    International Nuclear Information System (INIS)

    Roquefort, Henri

    1980-09-01

    The purpose of this document is to fix what terminology should be used, to define the main specifications of supplies and to specify the test methods recommended to check these specifications. This document applies to low and high voltage supply sub-units fed by AC or DC mains supply and delivering direct current under stabilised DC voltage. These sub-units are used in nuclear electronics equipment and especially for reactor monitoring. Following the definition of some terms, current notations and a bibliography, the characteristics section and the corresponding test methods section are developed. Each section deals in particular with: input and output characteristics, linearity and display errors, fluctuations, influence and operation errors, variations, drift (stability), variations with the main influence quantities: mains, temperature, load, transient variations, insulation, shielding, microbreakdowns, emergency supply, electromagnetic perturbation sensitivity, reliability, maintainability and characteristics specific to certain supplies used for the polarisation of radiation detectors [fr

  2. Data acquisition, remote control and equipment monitoring for ISOLDE RILIS

    CERN Document Server

    Rossel, R E; Richter, D; Wendt, K D A; Rothe, S; Marsh, B A

    2013-01-01

    With a steadily increasing on-line operation time up to a record 3000 h in the year 2012, the Resonance Ionization Laser Ion Source (RILIS) is one of the key components of the ISOLDE on-line isotope user facility at CERN. Ion beam production using the RILIS is essential for many experiments due to the unmatched combination of ionization efficiency and selectivity. To meet the reliability requirements the RILIS is currently operated in shift duty for continuous maintenance of crucial laser parameters such as wavelength, power, beam position and timing, as well as ensuring swift intervention in case of an equipment malfunction. A recent overhaul of the RILIS included the installation of new pump lasers, commercial dye lasers and a complementary, fully solid-state titanium:sapphire laser system. The framework of the upgrade also required the setup of a network-extended, LabVIEW-based system for data acquisition, remote control and equipment monitoring, to support RILIS operators as well as ISOLDE users. The syst...

  3. Close monitoring as a contextual stimulator : How need for structure affects the relation between close monitoring and work outcomes

    NARCIS (Netherlands)

    Rietzschel, Eric F.; Slijkhuis, Marjette; Van Yperen, Nico W.

    2014-01-01

    In this article, we argue and demonstrate that employees' Personal Need for Structure (PNS) moderates the negative effects of close monitoring on job satisfaction, intrinsic work motivation, and innovative job performance (as rated by their supervisors). In a field study (N=295), we found that

  4. Prototype equipment status monitor for plant operational configuration management

    International Nuclear Information System (INIS)

    DeVerno, M.; Trask, D.; Groom, S.

    1998-01-01

    CANDU plants, such as the Point Lepreau GS, have tens of thousands of operable devices. The status of each operable device must be immediately available to plan and execute future changes to the plant. Historically, changes to the plant's operational configuration have been controlled using manual and administrative methods where the status of each operable device is maintained on operational flowsheets located in the work control area of the main control room. The operational flowsheets are used to plan and develop Operating Orders (OOs) or Order-to-Operate (OTOs) and the control centre work processes are used to manage their execution. After performing each OO procedure, the operational flowsheets are updated to reflect the new plant configuration. This process can be very time consuming, and due to the manual processes, can lead to the potential for time lags and errors in the recording of the current plant configuration. Through a cooperative research and development program, Canadian CANDU utilities and Atomic Energy of Canada Limited, the design organization, have applied modern information technologies to develop a prototype Equipment Status Monitor (ESM) to address processes and information flow for efficient operational configuration management. The ESM integrates electronic operational flowsheets, equipment databases, engineering and work management systems, and computerized procedures to assess, plan, execute, track, and record changes to the plant's operational configuration. This directly leads to improved change control, more timely and accurate plant status information, fewer errors, and better decision making regarding future changes. These improvements to managing the plant's operational configuration are essential to increasing plant safety, achieving a high plant availability, and maintaining high capability and capacity factors. (author)

  5. Condition monitoring of electrical equipment in nuclear power plants

    International Nuclear Information System (INIS)

    Sugarman, A.

    1986-01-01

    Condition monitoring (CM) is a subset of maintenance testing. It is a quantitative, predictive technique for assessing the effects of all types of aging (environmental, cyclic, operational, etc) on the ''health'' of the equipment. A difference between CM and maintenance testing is that the latter is neither quantitative (i.e., measures the relative condition of the component or material as opposed to merely verifying that its condition is acceptable) nor predictive (i.e., makes judgments, on the ability of the component to perform at a future time). A common example of the principle of CM can be illustrated with the automobile which has a lifetime that is small enough to observe all the periods (break in, random failure, wear out) that occur throughout aging. There are several weak link components in the car (e.g., water hoses, contacts in the distributor, generator, spark plug cables, solenoid, etc) which if they fail will cause failure of the automobile to either start or run. From the day the car is put on the road and is subjected to heat and vibration, significant aging of these components occurs. Degradation in the water hoses, for example is manifested by the elastomeric casing becoming brittle and cracking

  6. Equipment monitoring and diagnosis of their mechanical condition

    International Nuclear Information System (INIS)

    Morel, J.; Monnier, B.

    1994-01-01

    The main objectives of reactor monitoring are reviewed and the three monitoring types are described: reception controls and alarms, periodical controls, and specific monitoring. The monitoring process is then presented: information acquisition, dysfunction detection and diagnosis, risk analysis and maintenance action determination. Diagnosis assistance is now automated with expert systems such as DIVA (shaft vibration diagnosis) and DIAPO (primary pump diagnosis). Several application examples at EDF are described: SEXTEN reactor containment tightness monitoring, large and small-size turbo-machine monitoring, reactor inner structure monitoring, loose part detection in the primary circuit. All these informations will be centralized in a general monitoring and diagnosis assistance station. 3 fig

  7. US8,994,532 "Data Center Equipment Location and Monitoring System"

    DEFF Research Database (Denmark)

    2014-01-01

    A data center equipment location system includes both hardware and software to provide for location, monitoring, security and identification of servers and other equipment in equipment racks. The system provides a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to a equipment rack controller on the equipment rack. The equipment rack controllers then link over a local area network to a central control computer. The central control computer provides an operator interface......, and runs a software application program that communicates with the equipment rack controllers. The software application program of the central control computer stores IDs of the equipment rack controllers and each of its connected electronic ID tags in a database. The software application program...

  8. Nuclear electronic equipment for control and monitoring boards. Susceptibility of nuclear electronic pulse equipment to interference

    International Nuclear Information System (INIS)

    Buisson, Jacques; Cochinal, R.; Duquesnoy, J.; Roquefort, H.

    1972-07-01

    The correct functioning of pulse measurement units in industrial environmental conditions where interference is high, frequently gives rise to many installation problems which are difficult to solve. This paper offers some recommendations with a view to minimising the effect to electric interference on electronic equipment and gives a test method which enables this effect to be assessed qualitatively. It has been devised for nuclear electronic instrumentation but it may also be applied to other equipment and in particular the test method may be used for other cases. After a few preliminaries on how interference acts and on the terminology, the design of the equipment and the recommended connections are mentioned. Test methods are then indicated, followed by various technical comments. (author) [fr

  9. Guideline for design and construction radiation monitoring equipments for Tokai reprocessing plant

    International Nuclear Information System (INIS)

    Miyabe, Kenjiro; Ninomiya, Kazushige; Jin, Kazumi; Morifuji, Masayuki; Nemoto, Kazuhiko; Sato, Akira; Kawai, Keiichi

    1999-12-01

    Various kind of radiation monitoring equipment are used in radiation controlled area at each facility of Tokai reprocessing plant. These equipments have been designed and constructed based on the users requirements, and permitted by governmental regulation office. And, design has been carried out in consideration of the adoption of the new technology and our operational experience. Then, it has been used effectively for the radiation control of the facilities. This report summarizes the technical requirements that should be taken into consideration in the design and installation of radiation monitoring equipments. These requirements are fundamentally applicable when the equipments of the new facilities will be designed or the present instruments will be replaced. (author)

  10. Technical diagnostics - equipment monitoring for increasing safety and availability of nuclear power plants

    International Nuclear Information System (INIS)

    Sturm, A.; Foerster, R.

    1977-01-01

    Utilization of technical diagnostics in equipment monitoring of nuclear power plants for ensuring nuclear safety, economic availability, and for decision making on necessary maintenance is reviewed. Technical diagnostics is subdivided into inspection and early detection of malfunctions. Moreover, combination of technical diagnostics and equipment monitoring, integration of technical diagnostics into maintenance strategy, and problems of introducing early detection of malfunctions into maintenance management of nuclear power plants are also discussed. In addition, a compilation of measuring techniques used in technical diagnostics has been made. The international state of the art of equipment monitoring in PWR nuclear power plants is illustrated by description of the sound and vibration measuring techniques. (author)

  11. Turbidity monitoring equipment and methodology evaluation at MDOT construction sites.

    Science.gov (United States)

    2014-12-01

    State Study 261 is a continuation of State study 225, "Turbidity Monitoring at Select : MDOT Construction Sites", which was successful in establishing baseline stream data : at several active construction sites. State Study 261 focused on the equipme...

  12. ''RESURS'' - The Russian scientific-technical programme for NPP equipment lifetime monitoring, estimation, prediction and management

    International Nuclear Information System (INIS)

    Emelyanov, V.

    1994-01-01

    RESURS programme is described implementation of which will allow to work out regulatory-methodological basis providing legal and technical solution of NPP equipment lifetime management, prediction, monitoring and estimation problems

  13. 40 CFR 63.2994 - How do I verify the performance of monitoring equipment?

    Science.gov (United States)

    2010-07-01

    ... equipment? (a) Before conducting the performance test, you must take the steps listed in paragraphs (a)(1) and (2) of this section: (1) Install and calibrate all process equipment, control devices, and... evaluation results. (b) If you use a thermal oxidizer, the temperature monitoring device must meet the...

  14. Condition based monitoring, diagnosis and maintenance on operating equipments of a hydraulic generator unit

    International Nuclear Information System (INIS)

    Liu, X T; Feng, F Z; Si, A W

    2012-01-01

    According to performance characteristics of operating equipments in a hydraulic generator unit (HGU), the relative techniques on condition monitoring and fault diagnosis (CMFD) are introduced in this paper, especially the key technologies are emphasized, such as equipment monitoring, expert system (ES), intelligent diagnosis and condition based maintenance (CBM). Meanwhile, according to the instructor on CBM proposed by State electric power corporation, based on integrated mode, the main steps on implementation of CBM are discussed in this paper.

  15. PWR fuel monitoring: recent progress with hot cells' examination equipment

    International Nuclear Information System (INIS)

    Chenebault, P.

    1989-01-01

    The 'hot' laboratories set up by the French Atomic Energy Authority (CEA) in its nuclear research centers at Saclay and Grenoble, and by the French Electricity Board (EDF) on the Chinon nuclear power station site, are used for dismantling and examining fuel rod assemblies irradiated in PWRs. This article is limited to a description of a number of new or totally updated items of equipment in these laboratories. Nuclear industry companies are also participating in the development of new examination techniques. As an example, the use of wave-guides for remote transmission of signals in a radioactive environment is described. 2 figs

  16. Universal Authenticated Item Monitoring System (AIMS) second generation equipment

    International Nuclear Information System (INIS)

    Schoeneman, J.L.; Baumann, M.J.; Fox, L.J.; Jenkins, C.D.; Perlinsk, A.W.

    1992-01-01

    Sandia National Laboratories (SNL) is in the final stages of developing a Universal Authenticated Item Monitoring System (AIMS). When completed, AIMS will provide applicable agencies in the US government, and those in the International arena, with a secure and convenient method of monitoring the physical status of selected items. The benefit derived from this development activity will be the commercial availability of an item monitoring system with the capability for ''quick set-up'' monitoring, as well as long-term unattended monitoring. The AIMS includes a variety of sensors, a robust and authenticated radio frequency (RF) communication link, a Receiver Processing Unit (RPU), and an inspector-friendly personal computer (PC) interface for collecting, sorting, viewing and archiving pertinent event histories. The system will provide the capability to monitor selected items in a real-time mode, a remotely interrogated mode, and a stand-alone, unattended data collection mode. The sensor suite under development includes advanced motion sensors, interior volumetric intrusion sensors, Re-usable, In-situ Verifiable Authenticated (RIVA) fiber-optic seal sensors, generic utility sensors (to accommodate contact closure inputs), and radiation and environmental sensors. A new generation authentication algorithm recently has been developed that provides a high degree of system security 121. The AIMS has potential safeguards applications in the areas of arms control and treaty verification military asset control, International Atomic Energy Agency (IAEA) and Euratom safeguards verification activities, as well as domestic nuclear safeguard activities. Commercial applications could include high-value inventory control and security systems. This paper describes the second-generation AIMS along with its recently expanded sensor suite and enhanced data collection capabilities

  17. Type of equipment in an air monitoring station

    International Nuclear Information System (INIS)

    Levy, F.

    1999-01-01

    This poster communication presents a general view of the station, the different materials used for the air and precipitations monitoring. The methods for gas measurements (tritium, krypton, iodine) are given. The collecting of dusts, dust and tritium mixed together, or rainwater and pluviometry are reviewed and the measurement of ambient radioactivity is made by beacon. (N.C.)

  18. Monitored Retrievable Storage conceptual system studies: closed-cycle vault

    International Nuclear Information System (INIS)

    Washington, J.A.; Ganley, J.T.

    1984-02-01

    The Nuclear Waste Policy Act of 1982 requires the DOE to submit a proposal to Congress by June 1985 for the construction of one or more Monitored Retrieval Storage (MRS) facilities. In response, the DOE initiated studies to develop system descriptions and cost estimates for preconceptual designs of storage concepts suitable for use at MRS facilities. This report provides a system description and cost estimates for a Closed-Cycle Vault (CCV) MRS facility. The facility description is divided into four parts: (1) the R and H area, (2) the interface facility, (3) the on-site transport system, and (4) the storage system. The MRS facility has been designed to meet handling rates of 1800 and 3000 MTU/yr. The corresponding peak inventories are 15,000 and 72,000 MTU. Three types of cases were considered, based on the material to be stored: (1) Spent fuel only; (2) HLW and TRU waste; and (3) HLW only. For each of these three types, a cost estimate was done for a 15,000 and a 72,000 MTU facility, resulting in six different cost estimates. Section 4 presents the cost analysis of the CCV MRS system. Tables 4-2 through 4-7 give the construction or capital costs for the six cases. Tables 4-8 through 4-13 show the total discounted life-cycle costs for each of the six cases. These life-cycle costs include operating and decommissioning costs. These tables also show the time distribution of the capital costs. Table 2-1 summarizes the capital, operating, and discounted costs for the six cases studied. 2 references, 15 figures, 18 tables

  19. Equipment performance monitoring in NPP Krsko (Summarized system health report)

    International Nuclear Information System (INIS)

    Djetelic, N.; Cicvaric, D.

    2004-01-01

    Management common goal is safe, reliable, effective, acceptable to public and conservative/cautious operation of NPP Krsko. A set of programs, including Corrective Action Program, Performance Indicators, Operating Experience, Self Assessment and System Health Report, is developed to assist NPP Krsko management in fulfilling those goals. System Health Report is a tool that management can use to quickly assess how selected systems are performing, to determine where additional management attention is required and to determine if appropriate corrective actions have been established. Summarized System Health Report is developed for management's quick overview of systems status, important system malfunctions and problems as well as major changes from previous assessment period. Summarized Report contains nine sections: status difference including brief explanation, selected performance indicators, new equipment problems, functional failures, important problem analyses, action plan for systems with Potential Danger (RED) status, maintenance rule status overview and systems availability (planned and unplanned).(author)

  20. 30 CFR 250.457 - What equipment is required to monitor drilling fluids?

    Science.gov (United States)

    2010-07-01

    ... monitor the drilling fluid returns. The indicator may be located in the drilling fluid-logging compartment... 30 Mineral Resources 2 2010-07-01 2010-07-01 false What equipment is required to monitor drilling... OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations...

  1. Radiation tolerance assurance of technical equipment in the LHC radiation monitoring for technical equipment at the LHC

    CERN Document Server

    Wijnands, Thijs; CERN. Geneva. TS Department

    2005-01-01

    In contrast with other accelerators at CERN, a large amount of technical equipment will be located in the LHC tunnel, the underground areas and in the experimental caverns where they will be exposed to radiation. Nearly all this equipment makes, to a certain extent, use of commercial microelectronics which is extremely sensitive to radiation damage, both instantaneous damage and cumulative damage. Examples in the TS Department are the electronics for the position sensors of the low beta quadrupoles, the access system, the cooling and ventilation units, the electronics for the electrical distribution, the oxygen deficiency monitors and fire detection systems. The basic effects of radiation on electronic systems and components are well understood because similar problems with radiation are encountered in the aerospace and aviation industry. Since 1998, an efficient and original Radiation Tolerance Assurance approach for the LHC machine has been established. Its aim is to minimise the effects of radiation damage...

  2. Criteria for the choice of a monitoring equipment

    International Nuclear Information System (INIS)

    Wieters, C.U.

    1999-01-01

    The user of a monitor unit for the detection of radioactive nuclides in scrap has to study the conditions for his special installation. It is very important to verify the way and the transport units for the scrap. For example, scrap delivery by rail shows little variation of transport unit size, way and position of the wagon with the disadvantage of big scrap cargoes. Lorries have a large variation in size and it is very difficult to have good measuring condition (position, speed etc.). Only the size is normally a little bit smaller than by rail. The next is to find the best location on the site for the logistic and measuring conditions. It must be assured that all the delivered scrap passed by this point with a documentation. The optimum of detection and verification of the measurements has to be prepared. The criteria for the sensitivity of the detectors to the ionising radiation must be found. In our company we declare a shielded radioactive Cs-137 source with a high activity, normally used in radiometric measuring units, having a dose rate at the surface near 7.5 pSv/h. This metal bloc has to be found in all positions of the scrap cargo. The other criteria for the choice of the monitor: unit are the maintenance, the control of function, sensitivity and price. The first installation of the monitor unit has to be controlled by a specialist with tests. It is also recommended to install a documentation of all measured cargoes. With this documentation it will be assured that all cargoes are controlled, and it is easier to clarify the reasons of malfunction like vibration, other sources (ceramic, radiometric sources, etc.). On our site, we installed finally two types of detectors, first in 1995 for the scrap delivered by rail working in the standing position of the wagon on the weight bridge. Therefore a small CsI detector, which is very sensitive to gamma rays, was installed with the best positions around the scrap-wagon. Second, for the delivery by road through

  3. Introduction of flexible monitoring equipment into the Greenlandic building sector

    DEFF Research Database (Denmark)

    Kotol, Martin; Heller, Alfred; Orthmann, Christian

    2014-01-01

    sensor network (WSN) technologies. The design of a prototype wireless monitoring and control system is demonstrated in the new dormitory Apisseq in Sisimiut, Greenland. The existing mechanical ventilation was running at a constant air volume even during unoccupied hours which resulted in a very high heat...... to be hardwired to the controller. In Greenland where price of the labor is very high and availability of experts limited the installation of such control system becomes unacceptably expensive, particularly in case of renovation of existing buildings. One possible solution to the above is to introduce wireless...... demand. It was estimated that installing the WSN system will bring annual savings of 1,600 € at the investment of 8,000 €. This paper describes the initial setup of the system and discusses its advantages and drawbacks....

  4. Development of an instrument for fast monitoring of radiotherapy equipment

    International Nuclear Information System (INIS)

    Khoury, H.J.; Almeida Melo, F. de; Patriota, J.H.; Oliveira Lira, C.B. de

    1990-01-01

    Radiation therapy machines need a constant monitoring to assure tumoral dose accuracy. Special attention must be given to linear accelerators which should be checked frequently. By this reason, an instrument was developed at the Nuclear Instrumentation Laboratory DEN/UFPE to measure the output energy and beam symmetry. This instrument use three silicon photodiodes as radiation detectors. Two of then were localized at 5cm and 10cm depht at the central axis and one at 5 cm from the center, at the lateral irradiated field. Changes in the photon spectrum are detected by the ratio of upper to lower photodiode response. The radiation field uniformity is checked by the lateral photodiode. (author) [pt

  5. Beam reliability and equipment downtime tracking how Lansce closes the loop

    International Nuclear Information System (INIS)

    Callaway, N.T.; Ryder, R.D.

    2003-01-01

    LANSCE uses a semi-automated accounting system to track how well we meet our stated beam delivery goals. When an equipment failure prevents delivery of the desired beam to our customers, the first order cause is identified and an accurate measurement of the downtime is recorded. For equipment downtimes of significant duration, we investigate the causes and make recommendations that will hopefully eliminate or mitigate the impact of similar downtimes in the future. (authors)

  6. Power levels in office equipment: Measurements of new monitors and personal computers

    International Nuclear Information System (INIS)

    Roberson, Judy A.; Brown, Richard E.; Nordman, Bruce; Webber, Carrie A.; Homan, Gregory H.; Mahajan, Akshay; McWhinney, Marla; Koomey, Jonathan G.

    2002-01-01

    Electronic office equipment has proliferated rapidly over the last twenty years and is projected to continue growing in the future. Efforts to reduce the growth in office equipment energy use have focused on power management to reduce power consumption of electronic devices when not being used for their primary purpose. The EPA ENERGY STAR[registered trademark] program has been instrumental in gaining widespread support for power management in office equipment, and accurate information about the energy used by office equipment in all power levels is important to improving program design and evaluation. This paper presents the results of a field study conducted during 2001 to measure the power levels of new monitors and personal computers. We measured off, on, and low-power levels in about 60 units manufactured since July 2000. The paper summarizes power data collected, explores differences within the sample (e.g., between CRT and LCD monitors), and discusses some issues that arise in m etering office equipment. We also present conclusions to help improve the success of future power management programs.Our findings include a trend among monitor manufacturers to provide a single very low low-power level, and the need to standardize methods for measuring monitor on power, to more accurately estimate the annual energy consumption of office equipment, as well as actual and potential energy savings from power management

  7. System for remote routine monitoring of power equipment at TPP and NPP

    International Nuclear Information System (INIS)

    Kantsedalov, V.G.; Samojlenko, V.P.; Doroshenko, V.A.

    1988-01-01

    A system for remote routine monitoring of TPP and NPP pipeline metals is described. The principal functional unit of the system is the unit of remote routine methods and techniques for studying and monitoring the metal and properties. The system is equipped with 5 types of routine monitoring equipment: robots, remote aggregated complexes, periodical diagnostic monitors, other means of metal diagnostics (endoscopes, introscopes). All current information enters the unit for estimating and forecasting the service life of power unit, where it is compared with the standard indices of reliability, duravility and efficiency. The system considered permits to reduce significantly or minimize the scope of works on metal monitoring during overhauls, increase intermonitoring and interrepairing compaigns to 8 years

  8. An open software system based on X Windows for process control and equipment monitoring

    International Nuclear Information System (INIS)

    Aimar, A.; Carlier, E.; Mertens, V.

    1992-01-01

    The construction and application of a configurable open software system for process control and equipment monitoring can speed up and simplify the development and maintenance of equipment specific software as compared to individual solutions. The present paper reports the status of such an approach for the distributed control systems of SPS and LEP beam transfer components, based on X Windows and the OSF/Motif tool kit and applying data modeling and software engineering methods. (author)

  9. Glance traceability – Web system for equipment traceability and radiation monitoring for the ATLAS experiment

    CERN Document Server

    Ramos de Azevedo Evora, L H; Pommes, K; Galvão, K K; Maidantchik, C

    2010-01-01

    During the operation, maintenance, and dismantling periods of the ATLAS Experiment, the traceability of all detector equipment must be guaranteed for logistic and safety matters. The running of the Large Hadron Collider will expose the ATLAS detector to radiation. Therefore, CERN must follow specific regulations from both the French and Swiss authorities for equipment removal, transport, repair, and disposal. GLANCE Traceability, implemented in C++ and Java/Java3D, has been developed to fulfill the requirements. The system registers and associates each equipment part to either a functional position in the detector or a zone outside the underground area through a 3D graphical user interface. Radiation control of the equipment is performed using a radiation monitor connected to the system: the local background gets stored and the threshold is automatically calculated. The system classifies the equipment as non radioactive if its radiation dose does not exceed that limit value. History for both location traceabi...

  10. Study on Communication Methods for Electric Power High-voltage Equipment Monitoring System

    Directory of Open Access Journals (Sweden)

    Jia Yu Chen

    2018-02-01

    Full Text Available Real-time monitoring of high-voltage equipment in substations is beneficial for early detection of faults. The use of wireless sensor networks to build monitoring system is an effective way, but the data collection is a difficult task. The author introduces a real-time monitoring system based on ZIGBEE and mobile communication technology. The system includes multiple monitoring points and terminal platforms. Each monitoring point consists of a number of sensor nodes to form a ZIGBEE network, detecting relevant parameters, coordinator node data collected one by one, known as linear transmission, and finally to the monitoring platform through the mobile communication network. This paper presents a fusion algorithm for monitoring cell data acquisition to reduce the amount of data uploaded to the base station. In addition, multi-hop routing algorithm based on opportunistic routing is proposed to balance network energy and improve network transmission rate and efficiency.

  11. The prevalence of visible and/or occult blood on anesthesia and monitoring equipment.

    Science.gov (United States)

    Perry, S M; Monaghan, W P

    2001-02-01

    The Occupational Safety and Health Administration (OSHA) and the Centers for Disease Control and Prevention (CDC) have attempted to stop the spread of blood-borne pathogens by issuing several recommendations and regulations. However, unless healthcare workers comply with these standards, they are not effective. In the anesthesia care environment, the anesthetist is responsible for ensuring that the equipment is clean, and disinfected, before use. We studied the prevalence of visible and occult blood on 6 types of anesthesia and monitoring equipment identified as ready for use in 28 operating suites, in 2 facilities. The sample consisted of 336 observations of the 6 types of equipment. The equipment was inspected for visible blood and then tested for occult blood using a 3-stage phenolphthalein test. Of the 336 observations, 110 (32.7%), were positive for occult blood with only 6 showing visible blood. The presence of blood on this equipment may be in direct violation of the OSHA Blood-borne Pathogen Standard and the infection control guidelines of the American Association of Nurse Anesthetists. Furthermore, the presence of blood on this equipment may increase the risk for nosocomial and occupational exposure to viral and bacterial pathogens. Recommendations were made to decrease the risks from this contamination by redesigning equipment, increasing the use of disposable equipment, and ensuring compliance with effective infection control practices.

  12. Deep Learning versus Professional Healthcare Equipment: A Fine-Grained Breathing Rate Monitoring Model

    Directory of Open Access Journals (Sweden)

    Bang Liu

    2018-01-01

    Full Text Available In mHealth field, accurate breathing rate monitoring technique has benefited a broad array of healthcare-related applications. Many approaches try to use smartphone or wearable device with fine-grained monitoring algorithm to accomplish the task, which can only be done by professional medical equipment before. However, such schemes usually result in bad performance in comparison to professional medical equipment. In this paper, we propose DeepFilter, a deep learning-based fine-grained breathing rate monitoring algorithm that works on smartphone and achieves professional-level accuracy. DeepFilter is a bidirectional recurrent neural network (RNN stacked with convolutional layers and speeded up by batch normalization. Moreover, we collect 16.17 GB breathing sound recording data of 248 hours from 109 and another 10 volunteers to train and test our model, respectively. The results show a reasonably good accuracy of breathing rate monitoring.

  13. Machine and lubricant condition monitoring for extended equipment lifetimes and predictive maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Lukas, M; Anderson, D P [Spectro Incorporated, Littleton, Massachusetts (United States)

    1998-12-31

    Predictive maintenance has gained wide acceptance as a cost cutting strategy in modern industry. Condition monitoring by lubricant analysis is one of the basic tools of a predictive maintenance program along with vibration monitoring, performance monitoring and thermography. In today`s modern power generation, manufacturing, refinery, transportation, mining, and military operations, the cost of equipment maintenance, service, and lubricants are ever increasing. Parts, labor, equipment downtime and lubricant prices and disposal costs are a primary concern in a well run maintenance management program. Machine condition monitoring based on oil analysis has become a prerequisite in most maintenance programs. Few operations can afford not to implement a program if they wish to remain competitive, and in some cases, profitable. This presentation describes a comprehensive Machine Condition Monitoring Program based on oil analysis. Actual operational condition monitoring programs will be used to review basic components and analytical requirements. Case histories will be cited as examples of cost savings, reduced equipment downtime and increased efficiencies of maintenance programs through a well managed oil analysis program. (orig.)

  14. Machine and lubricant condition monitoring for extended equipment lifetimes and predictive maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Lukas, M.; Anderson, D.P. [Spectro Incorporated, Littleton, Massachusetts (United States)

    1997-12-31

    Predictive maintenance has gained wide acceptance as a cost cutting strategy in modern industry. Condition monitoring by lubricant analysis is one of the basic tools of a predictive maintenance program along with vibration monitoring, performance monitoring and thermography. In today`s modern power generation, manufacturing, refinery, transportation, mining, and military operations, the cost of equipment maintenance, service, and lubricants are ever increasing. Parts, labor, equipment downtime and lubricant prices and disposal costs are a primary concern in a well run maintenance management program. Machine condition monitoring based on oil analysis has become a prerequisite in most maintenance programs. Few operations can afford not to implement a program if they wish to remain competitive, and in some cases, profitable. This presentation describes a comprehensive Machine Condition Monitoring Program based on oil analysis. Actual operational condition monitoring programs will be used to review basic components and analytical requirements. Case histories will be cited as examples of cost savings, reduced equipment downtime and increased efficiencies of maintenance programs through a well managed oil analysis program. (orig.)

  15. 77 FR 41930 - Bleed Air Cleaning and Monitoring Equipment and Technology

    Science.gov (United States)

    2012-07-17

    .... Bill 658, requires the FAA to identify bleed air purification technology. Specifically, the FAA seeks... Administration 14 CFR Part 25 [Docket No. FAA-2012-0714] Bleed Air Cleaning and Monitoring Equipment and... developers, manufacturers, and the public related to effective air cleaning technology and sensor technology...

  16. 40 CFR 141.561 - What happens if my system's turbidity monitoring equipment fails?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false What happens if my system's turbidity... Disinfection-Systems Serving Fewer Than 10,000 People Individual Filter Turbidity Requirements § 141.561 What happens if my system's turbidity monitoring equipment fails? If there is a failure in the continuous...

  17. 40 CFR 63.489 - Batch front-end process vents-monitoring equipment.

    Science.gov (United States)

    2010-07-01

    ... heater of less than 44 megawatts design heat input capacity is used, a temperature monitoring device in... operator may determine gas stream flow using the design blower capacity, with appropriate adjustments for... are required, each equipped with a continuous recorder. (6) Where a condenser is used, a condenser...

  18. Radiation protection instrumentation. Monitoring equipment. Atmospheric radioactive iodine in the environment

    International Nuclear Information System (INIS)

    1995-01-01

    This international standard applies to portable or installed equipment for the monitoring of radioactive iodine (such as I-131 or I-125) in air in the environment of nuclear installations during normal operation, during design basis events, and in emergency situations. The monitoring involves continuous sample trapping and, where adequate, automatic start of sampling. The document deals with radioactive iodine monitor design, testing procedures, and documentation. Appended tables refer to the reference and normal testing conditions, tests in normal testing conditions, tests during changes of the affecting quantities, and tests of changes in the air circuit. (P.A.)

  19. Standardization of radioactive gaseous waste radiation monitoring equipment from the International Electrotechnical Commission

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1983-01-01

    After having introduced the works performed by the International Electrotechnical Commission, the authors report on the results of the studies carried out to achieve the standardization of the radiation monitoring equipment concerning the control of the gaseous waste from nuclear installations. The authors present the most interesting aspects of the regulations and recommendations, which include not only a description of the minimum permissible levels of sensitivity for the monitors, but also a description of the set of assays to be established in order to verify the level of performance of the monitors

  20. Role of closely spaced modes in the seismic response of equipment and structures

    International Nuclear Information System (INIS)

    Nelson, F.C.

    1975-01-01

    The genesis for this study was a need for an explanation of how to combine the peak accelerations, displacements, stresses, etc., which result from a response spectrum analysis of nuclear power plant structures and equipment. The explanation was intended to be comprehensive in the sense that it would be based on a general principle from which the absolute sum, square root of the sum of the squares (SRSS), and double-sum modal recombination rules could be extracted as special cases. The purpose of such a comprehensive explanation was to convince design engineers that these rules, in particular the recently proposed double-sum rule, were logical in their formulation and therefore sensible in their application

  1. Environmental Monitoring Techniques and Equipment related to the installation and operation of Marine Energy Conversion Systems

    International Nuclear Information System (INIS)

    Scanu, Sergio; Carli, Filippo Maria; Piermattei, Viviana; Bonamano, Simone; Paladini de Mendoza, Francesco; Marcelli, Marco; Peviani, Maximo Aurelio; Dampney, Keith; Norris, Jennifer

    2015-01-01

    Results of activities under project Marine Renewables Infrastructure Network for Emerging Energy Technologies (MaRINET) are reported, which led to DEMTE, a database, created on the basis of standardized monitoring of the marine environment during installation, operation and decommissioning of Marine Energy Conversion Systems. Obtained with the consortium partners’ available techniques and equipment, the database shows that such instruments cover all identified marine environmental compartments, despite the lack of underwater vehicles and the reduced skills in using satellite technologies. These weaknesses could be overcome by an accurate planning of equipment, techniques and knowledge sharing. The approach here presented also leads to an effective analysis even in non-marine contexts

  2. Exploitation of condition monitoring technology for equipment by infrared thermography use

    International Nuclear Information System (INIS)

    Shimada, H.

    2005-01-01

    Recently exploitation of condition monitoring technology for equipment by infrared thermography use has been established in US nuclear power plants (NPPs) because of its effectiveness for accidents prevention. Meanwhile, this technology has never been used in Japanese NPPs. In order to make use of it with ease at NPPs, measuring manuals were provided including the table of emissivity dependent on equipment painting specification and measuring positions kept out of background heat sources at measurement. At in-site application tests, temperature increase points at power cable connection parts were discovered, which showed its effectiveness. (T. Tanaka)

  3. Enhancing reactor availability factor by diagnostic monitoring and data acquisition of electrical equipments

    International Nuclear Information System (INIS)

    Singh, G.

    2006-01-01

    Electrical energy has made significant contribution to rapid growth of industrial activity in the country. Development and improvement of energy conversion devices or electrical apparatus have supported the growth. Reliability is probably the most important factor in electrical supply system, not only to give uninterrupted service but to provide an economic supply. Regular diagnostic testing of electrical equipments will make a significant contribution to the reliability of electrical supply. The purpose of diagnostic monitoring is to recognize the development of faults at an early stage, which consequently allows greater freedom to schedule the outages resulting in lower downtime and lower capitalized losses. The insulation constitutes the heart of any electrical/power equipment. The insulation in power equipment in normal condition undergoes certain changes in the physical, chemical, electrical and mechanical properties. The change with respect to time in the presence of an influencing factor, more often a stress (electrical) is referred to as ageing. The deterioration of insulating material plays an important role in the assessing the condition of electrical equipments. The systematic diagnostic tests are also part of the maintenance program to ensure the continued serviceability of electrical equipments, by replacing or repairing the components likely to fail, as revealed by the test. Diagnostic tests are carried out on various electrical equipments for detection of incipient fault, location and judging their severity. (author)

  4. Challenges and Prospects of Equipment Health Monitoring with Wireless Sensor Network in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Chen, Dongyi; Jiang, Jin; Bari, Ataul; Wang, Quan; Hashemian, Hash-M.

    2014-01-01

    A wireless sensor network (WSN) system can offer tremendous benefits to equipment condition monitoring in newly-constructed and/or refurbished nuclear power plants (NPPs). However, it has not been widely accepted so far because of the following requirements by the NPP operators ectromagnetic (EM) emissions from the wireless transceivers must not interfere with the functionalities of the sensitive safety and protection systems in the plant, WSN must perform reliably in the presence of high levels of EM interference from devices such as relays and motor driven pumps, and ionizing radiation sources, dependable WSN performance in harsh industrial environments that are cluttered with cable trays, piping, valves, pumps, motors, and concrete and steel structures, and trict compliance with nuclear regulatory guidelines on EM emissions by the wireless devices. This paper will review the key issues associated with the deployment of WSN for equipment condition monitoring in NPPs. Some promising WSN technologies that can be used in NPP applications are also discussed

  5. Challenges and Prospects of Equipment Health Monitoring with Wireless Sensor Network in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Dongyi [University of Electronic Science and Technology of China, Chengdu (China); Jiang, Jin; Bari, Ataul; Wang, Quan [University of Western Ontario, Ontario (Canada); Hashemian, Hash-M. [AMS Technology Center Knoxville (United States)

    2014-08-15

    A wireless sensor network (WSN) system can offer tremendous benefits to equipment condition monitoring in newly-constructed and/or refurbished nuclear power plants (NPPs). However, it has not been widely accepted so far because of the following requirements by the NPP operators ectromagnetic (EM) emissions from the wireless transceivers must not interfere with the functionalities of the sensitive safety and protection systems in the plant, WSN must perform reliably in the presence of high levels of EM interference from devices such as relays and motor driven pumps, and ionizing radiation sources, dependable WSN performance in harsh industrial environments that are cluttered with cable trays, piping, valves, pumps, motors, and concrete and steel structures, and trict compliance with nuclear regulatory guidelines on EM emissions by the wireless devices. This paper will review the key issues associated with the deployment of WSN for equipment condition monitoring in NPPs. Some promising WSN technologies that can be used in NPP applications are also discussed.

  6. A system of radiation monitoring, and methods and equipment for measuring water of low specific activity

    International Nuclear Information System (INIS)

    Sivintsev, Yu.V.

    1975-01-01

    The author considers criteria for the radiation protection of the population and the environment. He describes the role of procedures for monitoring waters of low specific activity in the framework of a system for ensuring the radiation safety of the population living near a nuclear power station. The main technical characteristics (background, efficiency, sensitivity) of the laboratory equipment for gamma spectrometric analysis of water samples of low specific activity are discussed. (author)

  7. Safeguards equipment of the future integrated monitoring systems and remote monitoring

    International Nuclear Information System (INIS)

    Sonnier, C.S.; Johnson, C.S.

    1994-01-01

    Becoming aware of the significant events of the past four years and their effect on the expectations to international safeguards, it is necessary to reflect on which direction the development of nuclear safeguards in a new era needs to take and the implications. The lime proven monitoring techniques, based on quantitative factor's and demonstrated universal application, have shown their merit. However, the new expectations suggest a possibility that a future IAEA safeguards system could rely more heavily on the value of a comprehensive, transparent and open implementation regime. Within such a regime, the associated measures need to be determined and technological support identified. This paper will identify the proven techniques which, with appropriate implementation support, could most quickly make available additional measures for a comprehensive, transparent and open implementation regime. In particular, it will examine the future of Integrated Monitoring Systems and Remote Monitoring in international safeguards, including technical and other related factors

  8. Optimization of the monitoring of landfill gas and leachate in closed methanogenic landfills.

    Science.gov (United States)

    Jovanov, Dejan; Vujić, Bogdana; Vujić, Goran

    2018-06-15

    Monitoring of the gas and leachate parameters in a closed landfill is a long-term activity defined by national legislative worldwide. Serbian Waste Disposal Law defines the monitoring of a landfill at least 30 years after its closing, but the definition of the monitoring extent (number and type of parameters) is incomplete. In order to define and clear all the uncertainties, this research focuses on process of monitoring optimization, using the closed landfill in Zrenjanin, Serbia, as the experimental model. The aim of optimization was to find representative parameters which would define the physical, chemical and biological processes in the closed methanogenic landfill and to make this process less expensive. Research included development of the five monitoring models with different number of gas and leachate parameters and each model has been processed in open source software GeoGebra which is often used for solving optimization problems. The results of optimization process identified the most favorable monitoring model which fulfills all the defined criteria not only from the point of view of mathematical analyses, but also from the point of view of environment protection. The final outcome of this research - the minimal required parameters which should be included in the landfill monitoring are precisely defined. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Design of online monitoring and forecasting system for electrical equipment temperature of prefabricated substation based on WSN

    Science.gov (United States)

    Qi, Weiran; Miao, Hongxia; Miao, Xuejiao; Xiao, Xuanxuan; Yan, Kuo

    2016-10-01

    In order to ensure the safe and stable operation of the prefabricated substations, temperature sensing subsystem, temperature remote monitoring and management subsystem, forecast subsystem are designed in the paper. Wireless temperature sensing subsystem which consists of temperature sensor and MCU sends the electrical equipment temperature to the remote monitoring center by wireless sensor network. Remote monitoring center can realize the remote monitoring and prediction by monitoring and management subsystem and forecast subsystem. Real-time monitoring of power equipment temperature, history inquiry database, user management, password settings, etc., were achieved by monitoring and management subsystem. In temperature forecast subsystem, firstly, the chaos of the temperature data was verified and phase space is reconstructed. Then Support Vector Machine - Particle Swarm Optimization (SVM-PSO) was used to predict the temperature of the power equipment in prefabricated substations. The simulation results found that compared with the traditional methods SVM-PSO has higher prediction accuracy.

  10. An Updated Methodology for Enhancing Risk Monitors with Integrated Equipment Condition Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Ramuhalli, Pradeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hirt, Evelyn H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Coles, Garill A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bonebrake, Christopher A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ivans, William J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wootan, David W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mitchell, Mark R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-07-18

    Small modular reactors (SMRs) generally include reactors with electric output of ~350 MWe or less (this cutoff varies somewhat but is substantially less than full-size plant output of 700 MWe or more). Advanced SMRs (AdvSMRs) refer to a specific class of SMRs and are based on modularization of advanced reactor concepts. Enhancing affordability of AdvSMRs will be critical to ensuring wider deployment, as AdvSMRs suffer from loss of economies of scale inherent in small reactors when compared to large (~greater than 600 MWe output) reactors and the controllable day-to-day costs of AdvSMRs will be dominated by operation and maintenance (O&M) costs. Technologies that help characterize real-time risk are important for controlling O&M costs. Risk monitors are used in current nuclear power plants to provide a point-in-time estimate of the system risk given the current plant configuration (e.g., equipment availability, operational regime, and environmental conditions). However, current risk monitors are unable to support the capability requirements listed above as they do not take into account plant-specific normal, abnormal, and deteriorating states of active components and systems. This report documents technology developments towards enhancing risk monitors that, if integrated with supervisory plant control systems, can provide the capability requirements listed and meet the goals of controlling O&M costs. The report describes research results on augmenting an initial methodology for enhanced risk monitors that integrate real-time information about equipment condition and POF into risk monitors. Methods to propagate uncertainty through the enhanced risk monitor are evaluated. Available data to quantify the level of uncertainty and the POF of key components are examined for their relevance, and a status update of this data evaluation is described. Finally, we describe potential targets for developing new risk metrics that may be useful for studying trade-offs for economic

  11. Design and implementation of equipment for monitoring the salinity in the subsoil

    Directory of Open Access Journals (Sweden)

    Mariano Norzagaray Campos

    2012-09-01

    Full Text Available Geochemical exploration equipments to explore the contaminants and structures geological in the subsoil come from abroad are expensive and sometimes parts for replacement are not available in the market. So it is necessary design apparatus that meet cover these needs. To the monitoring of variations in salinity there is semi-automatic equipment, but it always has difficult to manage. However, is not equipment for the indirect study of salinity in the subsoil. In this work was design equipment for measurement the apparent resistivity in the subsoil, at same time allow know the salinity, as well as the detection of any pollutant in groundwater. For make it, was selected a design of earthing systems, with electronic hardware which were jointed for apply to subsoil a direct current (DC through an array dipole-dipole and vertical electric sounding, with brass and stainless steel electrodes. In the earthing systems the electrodes were collocated in the equidistant line between the detectors of potential and current. A geometric factor (K, that depend on theelectrodes distance and direct current (I injected in the electrodes A and B, was used for measure the potential difference between the electrodes M and N; after was calculate the resistivity point to point for obtain a subsoil tomography geoelectrical. The equipment was calibrated with minimum error (rms < 2% whit respect to curves obtained in similar commercial equipment. On this situation, in this work was modernized and automated an equipment to determine thesalinity of the subsoil. The instrument was tasted in the micro basin Texcoco, State of Mexico, to define the environment geometry formed by alluvial or lake sediments from igneous rocks (andesites, rhyolites and tuffs vitreous or “tepetates” which by its mineralogical composition allowed to the lateral resistivity be associate with free components trace from the aquifer: Cd, Cu, Cr, Co, Ni, Pb or Zn and others. This method constitutes

  12. RESUME95 Nordic field test of mobile equipment for nuclear fall-out monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bourgeois, C.; Bresson, J.; Chiffot, T.; Guillot, L. [Centre d`Etudes de Valduc, Direction des Applications Militaires, Commissaiat a L`Energie Atomique, Tille (France)

    1997-12-31

    Nordic Safety Research (NKS) organised in August 1995 a field test of various techniques and instrumentation for monitoring radioactive fall-out. In an emergency situation, after a major release of radioactive material, many different measuring systems are going to be used, ranging from small hand hold intensitometer to complex spectrometer systems. In this test the following type of equipment were tested: Airborne spectrometers; Carborne spectrometers and dose rate meters; In situ spectrometers and intensitometers. Helinuc team was equipped of an airborne system and of a germanium device for in situ measurements. Different tasks were specified for each team: Mapping caesium fall-out and natural activity over two areas of 18 and 5 km{sup 2}; Research of hidden sources. For measurements and data processing the respect of time allowed was strictly controlled for testing the ability of each team. (au).

  13. RESUME95 Nordic field test of mobile equipment for nuclear fall-out monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bourgeois, C; Bresson, J; Chiffot, T; Guillot, L [Centre d` Etudes de Valduc, Direction des Applications Militaires, Commissaiat a L` Energie Atomique, Tille (France)

    1998-12-31

    Nordic Safety Research (NKS) organised in August 1995 a field test of various techniques and instrumentation for monitoring radioactive fall-out. In an emergency situation, after a major release of radioactive material, many different measuring systems are going to be used, ranging from small hand hold intensitometer to complex spectrometer systems. In this test the following type of equipment were tested: Airborne spectrometers; Carborne spectrometers and dose rate meters; In situ spectrometers and intensitometers. Helinuc team was equipped of an airborne system and of a germanium device for in situ measurements. Different tasks were specified for each team: Mapping caesium fall-out and natural activity over two areas of 18 and 5 km{sup 2}; Research of hidden sources. For measurements and data processing the respect of time allowed was strictly controlled for testing the ability of each team. (au).

  14. Technical Report on Preliminary Methodology for Enhancing Risk Monitors with Integrated Equipment Condition Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Ramuhalli, Pradeep; Coles, Garill A.; Coble, Jamie B.; Hirt, Evelyn H.

    2013-09-17

    Small modular reactors (SMRs) generally include reactors with electric output of ~350 MWe or less (this cutoff varies somewhat but is substantially less than full-size plant output of 700 MWe or more). Advanced SMRs (AdvSMRs) refer to a specific class of SMRs and are based on modularization of advanced reactor concepts. AdvSMRs may provide a longer-term alternative to traditional light-water reactors (LWRs) and SMRs based on integral pressurized water reactor concepts currently being considered. Enhancing affordability of AdvSMRs will be critical to ensuring wider deployment. AdvSMRs suffer from loss of economies of scale inherent in small reactors when compared to large (~greater than 600 MWe output) reactors. Some of this loss can be recovered through reduced capital costs through smaller size, fewer components, modular fabrication processes, and the opportunity for modular construction. However, the controllable day-to-day costs of AdvSMRs will be dominated by operation and maintenance (O&M) costs. Technologies that help characterize real-time risk are important for controlling O&M costs. Risk monitors are used in current nuclear power plants to provide a point-in-time estimate of the system risk given the current plant configuration (e.g., equipment availability, operational regime, and environmental conditions). However, current risk monitors are unable to support the capability requirements listed above as they do not take into account plant-specific normal, abnormal, and deteriorating states of active components and systems. This report documents technology developments that are a step towards enhancing risk monitors that, if integrated with supervisory plant control systems, can provide the capability requirements listed and meet the goals of controlling O&M costs. The report describes research results from an initial methodology for enhanced risk monitors by integrating real-time information about equipment condition and POF into risk monitors.

  15. Monitoring of energy efficiency of technological modes of gas transport using modern gas-turbine equipment

    Science.gov (United States)

    Golik, V. V.; Zemenkova, M. Yu; Shipovalov, A. N.; Akulov, K. A.

    2018-05-01

    The paper presents calculations and an example of energy efficiency justification of the regimes of the equipment used. The engineering design of the gas pipeline in the part of monitoring the energy efficiency of a gas compressor unit (GCU) is considered. The results of the GCU characteristics and its components evaluation are described. The evaluation results of the energy efficiency indicators of the gas pipeline are presented. As an example of the result of the analysis, it is proposed to use gas compressor unit GCU-32 "Ladoga" because of its efficiency and cost effectiveness, in comparison with analogues.

  16. Off-label psychopharmacologic prescribing for children: History supports close clinical monitoring

    Directory of Open Access Journals (Sweden)

    Fegert Joerg M

    2008-09-01

    Full Text Available Abstract The review presents pediatric adverse drug events from a historical perspective and focuses on selected safety issues associated with off-label use of medications for the psychiatric treatment of youth. Clinical monitoring procedures for major psychotropic drug classes are reviewed. Prior studies suggest that systematic treatment monitoring is warranted so as to both minimize risk of unexpected adverse events and exposures to ineffective treatments. Clinical trials to establish the efficacy and safety of drugs currently being used off-label in the pediatric population are needed. In the meantime, clinicians should consider the existing evidence-base for these drugs and institute close clinical monitoring.

  17. Application of wireless LAN technology to remote monitoring for inspection equipment

    International Nuclear Information System (INIS)

    Ishiyama, Koichi; Kimura, Takashi; Miura, Yasushi; Yamaguchi, Katsuhiro; Kabuki, Toshihide

    2011-01-01

    To support inspections under an Integrated Safeguards regime into Tokai Reprocessing Plant (TRP), the IAEA suggested making use of Remote Monitoring (RM) capabilities to the inspection equipment (surveillance camera and NDA systems) installed in the spent fuel storage area at TRP. Since TRP had no pre-prepared cabling infrastructure for data transmission in the spent fuel storage area, the option of wireless LAN was chosen over the telephone line due to its lower installation costs. Feasibility studies and tests were performed by TRP on communication and particularly on long-term continuous communication using wireless LAN equipment composed of APs (AP: Access Point) and the external antennas for introducing wireless LAN technology to RM. As a result it was recognized that wireless LAN has enough ability to communicate for long periods of time and consequently the IAEA installed the AP and the external antenna to each inspection equipment and the wireless LAN technology was applied for RM. In this paper, the summary of each test and the results are reported. (author)

  18. MONITORING OF THE PERFORMANCE EFFICIENCY OF THE EQUIPMENT AT THE ENTERPRISES OF AVIATION INSTRUMENTATION

    Directory of Open Access Journals (Sweden)

    Petr P. Dobrov

    2016-01-01

    Full Text Available The article elaborates the proposals to improve the systems for monitoring performance of the equipment at the enterprises of aviation instrument. The relevance of the study due to the fact that the aviation instrument-making industry of the Russian Federation can play a role as a key factor in enhancing the competitiveness of the national economy. Currently, the global aviation market is fairly saturated, it competition is not between individual companies and between the aviation powers. The role of an efficient industrial production is largely dependent on the amount, structure, technical condition and the level of utilization of fixed assets. Specificity of high-tech high-tech production presupposes the existence of a specific fleet of expensive and unique equipment; a high degree of novelty products, single or small-scale type of production that determines the high cost of production of a unit of production; high demands on the staff . The paper noted that the production capacity is an essential tool for production planning process, which allows to determine the optimal work shifts Park main technological equipment and production program to justify the enterprises of sphere of aviation instrument. On the basis of the modification of OEE method, a stochastic model is proposed, which allows to display the efficiency of the productive capacity of the high-tech enterprises of sphere of aviation instrument in the form of multi-dimensional size and much more accurately identify the relationship between its elements.

  19. Research on development of multi-channel analyzer used for monitoring and warning radiation equipment

    International Nuclear Information System (INIS)

    Nguyen Van Sy; Dang Quang Thieu; Nguyen Thi Bao My

    2015-01-01

    The subject assigned to this paper presents research on development of multi-channel analyzer used for monitoring and warning environmental radiation equipment under the project KC.05.16/11-15 Research on manufacturing equipment monitoring and warning radiation. In this thematic we have two subjects that need to be resolved such as: i) Designing spectroscopy amplifier block (AMP) duty pulse signals obtained about few hundred millivolts output from scintillation detector preamplifier, amplified as a few volts and the standard Gaussian pulses shaped to connect to the analog-to-digital converter. The spectroscopy amplifier block can change the gain by digital control to respond to the problem of automatic spectrum stability for multi-channel analyzer systems. ii) Designing analog-to-digital converter block (ADC) in accordance with the actual conditions, such as high stability, fast conversion time, high throughput, and it consumes low energy. Selecting suitable microprocessor for fast connection ability, to operate reliably paired with the analog-to-digital converter into a multi-channel analyzer (MCA) serving analysis. (author)

  20. Close monitoring as a contextual stimulator: how need for structure affects the

    NARCIS (Netherlands)

    Nico W. Van Yperen; Eric F. Rietzschel; Marjette Slijkhuis

    2014-01-01

    In this article, we argue and demonstrate that employees’ Personal Need for Structure (PNS) moderates the negative effects of close monitoring on job satisfaction, intrinsic work motivation, and innovative job performance (as rated by their supervisors). In a field study (N ¼ 295), we found that

  1. Property-close source separation of hazardous waste and waste electrical and electronic equipment - A Swedish case study

    International Nuclear Information System (INIS)

    Bernstad, Anna; Cour Jansen, Jes la; Aspegren, Henrik

    2011-01-01

    Through an agreement with EEE producers, Swedish municipalities are responsible for collection of hazardous waste and waste electrical and electronic equipment (WEEE). In most Swedish municipalities, collection of these waste fractions is concentrated to waste recycling centres where households can source-separate and deposit hazardous waste and WEEE free of charge. However, the centres are often located on the outskirts of city centres and cars are needed in order to use the facilities in most cases. A full-scale experiment was performed in a residential area in southern Sweden to evaluate effects of a system for property-close source separation of hazardous waste and WEEE. After the system was introduced, results show a clear reduction in the amount of hazardous waste and WEEE disposed of incorrectly amongst residual waste or dry recyclables. The systems resulted in a source separation ratio of 70 wt% for hazardous waste and 76 wt% in the case of WEEE. Results show that households in the study area were willing to increase source separation of hazardous waste and WEEE when accessibility was improved and that this and similar collection systems can play an important role in building up increasingly sustainable solid waste management systems.

  2. The Design and Implementation of the Remote Centralized-Monitoring System of Well-Control Equipment Based on RFID Technique

    Directory of Open Access Journals (Sweden)

    Luo Bin

    2017-01-01

    Full Text Available At present, in domestic for the management of well control equipment continue to the traditional way of nameplates identifies and paper-based registration, there are many issues like the separation of data information of device, easy lose, difficult query, confused management and many other problems, which will make the problem device into the well field, and then resulting in well control runaway drilling accident. To solve the above problems, this paper put forward to the integrated remote centralized-monitoring management mode of the well-control equipment. Taking the advantages of IOT technology, adopting the RFID technology, and combining with the remote transmission, this paper designs the remote centralized-monitoring system of well-control equipment based on RFID, which realizes the intelligent management of well-control equipment and meets the actual demand of the well-control equipment safe use and timely scheduling, and it has the ability of field application.

  3. A Static Displacement Monitoring System for VLBI Antenna Using Close-Range Photogrammetry

    Directory of Open Access Journals (Sweden)

    Hyukgil Kim

    2017-11-01

    Full Text Available In this study, a static displacement monitoring program was developed to maintain the accurate performance of a Very Long Baseline Interferometry (VLBI antenna by monitoring its structural stability. The monitoring program was designed to measure static displacement, among the many displacements of the antenna’s main reflector, which can directly affect its performance. The program measures the position of a monitored object with mm-level accuracy through close-range photogrammetry that uses high-resolution Charge Coupled Device (CCD cameras. The developed program will be used to evaluate the structural soundness of an antenna based on continuous displacement measurements, which can also be used as basic data for repair and reinforcement work in the future.

  4. Preliminary Study of UAS Equipped with Thermal Camera for Volcanic Geothermal Monitoring in Taiwan.

    Science.gov (United States)

    Chio, Shih-Hong; Lin, Cheng-Horng

    2017-07-18

    Thermal infrared cameras sense the temperature information of sensed scenes. With the development of UASs (Unmanned Aircraft Systems), thermal infrared cameras can now be carried on a quadcopter UAV (Unmanned Aircraft Vehicle) to appropriately collect high-resolution thermal images for volcanic geothermal monitoring in a local area. Therefore, the quadcopter UAS used to acquire thermal images for volcanic geothermal monitoring has been developed in Taiwan as part of this study to overcome the difficult terrain with highly variable topography and extreme environmental conditions. An XM6 thermal infrared camera was employed in this thermal image collection system. The Trimble BD970 GNSS (Global Navigation Satellite System) OEM (Original Equipment Manufacturer) board was also carried on the quadcopter UAV to gather dual-frequency GNSS observations in order to determine the flying trajectory data by using the Post-Processed Kinematic (PPK) technique; this will be used to establish the position and orientation of collected thermal images with less ground control points (GCPs). The digital surface model (DSM) and thermal orthoimages were then produced from collected thermal images. Tests conducted in the Hsiaoyukeng area of Taiwan's Yangmingshan National Park show that the difference between produced DSM and airborne LIDAR (Light Detection and Ranging) data are about 37% between -1 m and 1 m, and 66% between -2 m and 2 m in the area surrounded by GCPs. As the accuracy of thermal orthoimages is about 1.78 m, it is deemed sufficient for volcanic geothermal monitoring. In addition, the thermal orthoimages show some phenomena not only more globally than do the traditional methods for volcanic geothermal monitoring, but they also show that the developed system can be further employed in Taiwan in the future.

  5. Preliminary Study of UAS Equipped with Thermal Camera for Volcanic Geothermal Monitoring in Taiwan

    Directory of Open Access Journals (Sweden)

    Shih-Hong Chio

    2017-07-01

    Full Text Available Thermal infrared cameras sense the temperature information of sensed scenes. With the development of UASs (Unmanned Aircraft Systems, thermal infrared cameras can now be carried on a quadcopter UAV (Unmanned Aircraft Vehicle to appropriately collect high-resolution thermal images for volcanic geothermal monitoring in a local area. Therefore, the quadcopter UAS used to acquire thermal images for volcanic geothermal monitoring has been developed in Taiwan as part of this study to overcome the difficult terrain with highly variable topography and extreme environmental conditions. An XM6 thermal infrared camera was employed in this thermal image collection system. The Trimble BD970 GNSS (Global Navigation Satellite System OEM (Original Equipment Manufacturer board was also carried on the quadcopter UAV to gather dual-frequency GNSS observations in order to determine the flying trajectory data by using the Post-Processed Kinematic (PPK technique; this will be used to establish the position and orientation of collected thermal images with less ground control points (GCPs. The digital surface model (DSM and thermal orthoimages were then produced from collected thermal images. Tests conducted in the Hsiaoyukeng area of Taiwan’s Yangmingshan National Park show that the difference between produced DSM and airborne LIDAR (Light Detection and Ranging data are about 37% between −1 m and 1 m, and 66% between −2 m and 2 m in the area surrounded by GCPs. As the accuracy of thermal orthoimages is about 1.78 m, it is deemed sufficient for volcanic geothermal monitoring. In addition, the thermal orthoimages show some phenomena not only more globally than do the traditional methods for volcanic geothermal monitoring, but they also show that the developed system can be further employed in Taiwan in the future.

  6. An intelligent service matching method for mechanical equipment condition monitoring using the fibre Bragg grating sensor network

    Science.gov (United States)

    Zhang, Fan; Zhou, Zude; Liu, Quan; Xu, Wenjun

    2017-02-01

    Due to the advantages of being able to function under harsh environmental conditions and serving as a distributed condition information source in a networked monitoring system, the fibre Bragg grating (FBG) sensor network has attracted considerable attention for equipment online condition monitoring. To provide an overall conditional view of the mechanical equipment operation, a networked service-oriented condition monitoring framework based on FBG sensing is proposed, together with an intelligent matching method for supporting monitoring service management. In the novel framework, three classes of progressive service matching approaches, including service-chain knowledge database service matching, multi-objective constrained service matching and workflow-driven human-interactive service matching, are developed and integrated with an enhanced particle swarm optimisation (PSO) algorithm as well as a workflow-driven mechanism. Moreover, the manufacturing domain ontology, FBG sensor network structure and monitoring object are considered to facilitate the automatic matching of condition monitoring services to overcome the limitations of traditional service processing methods. The experimental results demonstrate that FBG monitoring services can be selected intelligently, and the developed condition monitoring system can be re-built rapidly as new equipment joins the framework. The effectiveness of the service matching method is also verified by implementing a prototype system together with its performance analysis.

  7. Nuclear electronic equipment for control and monitoring panel. Specifications and methods for testing radiation detectors

    International Nuclear Information System (INIS)

    Roguin, Andre.

    1976-02-01

    This document will be of interest to users and makers of neutron and gamma radiations detectors in the field of nuclear reactor control and protection. Information is given which will enable users to optimize their choice and methods of using equipment, and makers to optimize their methods of fabrication. It should also serve as a model from which official specifications, technical instructions and test methods for these detectors, could be established. A detailed description is given of the appropriate parameters, terminology and notations. General specifications, operating conditions and test methods are indicated. The following detectors are studied: in-core detectors: fission ionization chambers, self powered neutron detectors (S.P.N.D.); out-core detectors: boron ionization chambers (for monitoring), boron trifluoride proportional counter tubes, boron lined proportional counter tubes, helium-3 proportional counter tubes. The devices described in the document are intended for industrial radiation monitoring applications and not for calibration standards (dosimetry) or for health physics measurement purposes. They are characterized by their fidelity, fast response, reliability and long lifetimes [fr

  8. Technical Needs for Enhancing Risk Monitors with Equipment Condition Assessment for Advanced Small Modular Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Coble, Jamie B.; Coles, Garill A.; Ramuhalli, Pradeep; Meyer, Ryan M.; Berglin, Eric J.; Wootan, David W.; Mitchell, Mark R.

    2013-04-04

    Advanced small modular reactors (aSMRs) can provide the United States with a safe, sustainable, and carbon-neutral energy source. The controllable day-to-day costs of aSMRs are expected to be dominated by operation and maintenance costs. Health and condition assessment coupled with online risk monitors can potentially enhance affordability of aSMRs through optimized operational planning and maintenance scheduling. Currently deployed risk monitors are an extension of probabilistic risk assessment (PRA). For complex engineered systems like nuclear power plants, PRA systematically combines event likelihoods and the probability of failure (POF) of key components, so that when combined with the magnitude of possible adverse consequences to determine risk. Traditional PRA uses population-based POF information to estimate the average plant risk over time. Currently, most nuclear power plants have a PRA that reflects the as-operated, as-modified plant; this model is updated periodically, typically once a year. Risk monitors expand on living PRA by incorporating changes in the day-by-day plant operation and configuration (e.g., changes in equipment availability, operating regime, environmental conditions). However, population-based POF (or population- and time-based POF) is still used to populate fault trees. Health monitoring techniques can be used to establish condition indicators and monitoring capabilities that indicate the component-specific POF at a desired point in time (or over a desired period), which can then be incorporated in the risk monitor to provide a more accurate estimate of the plant risk in different configurations. This is particularly important for active systems, structures, and components (SSCs) proposed for use in aSMR designs. These SSCs may differ significantly from those used in the operating fleet of light-water reactors (or even in LWR-based SMR designs). Additionally, the operating characteristics of aSMRs can present significantly different

  9. Cycle chemistry monitoring system as means of improving the reliability of the equipment at the power plants

    Science.gov (United States)

    Yegoshina, O. V.; Voronov, V. N.; Yarovoy, V. O.; Bolshakova, N. A.

    2017-11-01

    There are many problems in domestic energy at the present that require urgent solutions in the near future. One of these problems - the aging of the main and auxiliary equipment. Wear of equipment is the cause of decrease reliability and efficiency of power plants. Reliability of the equipment are associated with the introduction of cycle chemistry monitoring system. The most damageable equipment’s are boilers (52.2 %), turbines (12.6 %) and heating systems (12.3 %) according to the review of failure rate on the power plants. The most part of the damageability of the boiler is heated surfaces (73.2 %). According to the Russian technical requirements, the monitoring systems are responsible to reduce damageability the boiler heating surfaces and to increase the reliability of the equipment. All power units capacity of over 50 MW are equipped with cycle chemistry monitoring systems in order to maintain water chemistry within operating limits. The main idea of cycle chemistry monitoring systems is to improve water chemistry at power plants. According to the guidelines, cycle chemistry monitoring systems of a single unit depends on its type (drum or once-through boiler) and consists of: 20…50 parameters of on-line chemical analyzers; 20…30 «grab» sample analyses (daily) and about 15…20 on-line monitored operating parameters. The operator of modern power plant uses with many data at different points of steam/water cycle. Operators do not can estimate quality of the cycle chemistry due to the large volume of daily and every shift information and dispersion of data, lack of systematization. In this paper, an algorithm for calculating the quality index developed for improving control the water chemistry of the condensate, feed water and prevent scaling and corrosion in the steam/water cycle.

  10. Cosmic radiation monitoring equipment for the Ministry of Posts and Telecommunications; Yuseisho muke uchu denpa kanshi shisetsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    The equipment analyzes radio waves transmitted by a geostationary satellite toward the earth and collates the received waves to the registered satellite data for the exposure of illegality or unlawfulness, if any. A feature of the equipment is that it operates only one antenna to catch waves belonging in three different frequency bands, that is, L, Ku, and Ka. Another feature is that it follows a procedure which is automatically executed by computers, the procedure including the analysis of the spectrum of the continuously arriving waves for the isolation of the carrier wave for the determination of the position where the satellite rests and for the extraction of wave data. Cosmic radiation monitoring is manually performed in Germany, Britain, etc., and the equipment introduced here is the first computer-aided automatic cosmic radiation monitoring system in the world. (translated by NEDO)

  11. Monitoring and energetic performance of two similar semi-closed greenhouse ventilation systems

    International Nuclear Information System (INIS)

    Coomans, Mathias; Allaerts, Koen; Wittemans, Lieve; Pinxteren, Dave

    2013-01-01

    Highlights: • Measurements on two semi-closed greenhouses and two traditional open greenhouses. • Mechanical and natural ventilation for dehumidification and cooling. • Analyses and comparison of installation controls, indoor climate and energy flows. • Examination of air-to-air heat recuperation efficiency in ventilation unit. • Using the semi-closed systems amounted to energy savings of 13% and 28%. - Abstract: Horticulture is an energy intensive industry when dealing with cold climates such as Western Europe. High energy prices and on-going pressure from international competition are raising demand for energy efficient solutions. In search of reducing greenhouse energy consumption, this study investigates semi-closed systems combining controlled mechanical and natural ventilation with thermal screens. Ventilated greenhouse systems (semi-closed) have been implemented in the greenhouse compartments of two Belgian horticulture research facilities: the Research Station for Vegetable Production Sint-Katelijne-Waver (PSKW) and the Research Center Hoogstraten (PCH). Additionally, two reference compartments were included for comparison of the results. The greenhouses were part of a long-term monitoring campaign in which detailed measurements with a high time resolution were gathered by a central monitoring system. A large amount of data was processed and analysed, including outdoor and indoor climatic parameters, system controls and installation measurements. The ventilated greenhouses obtained energy savings of 13% and 28% for PSKW and PCH respectively, without substantial impact on crop production or indoor climate conditions when compared to the reference compartments. A considerable amount of heat was recovered by the heat recuperation stage in the ventilation unit of PCH, accounting for 12% of the total heat demand. In general, it was demonstrated that the greenhouse heat demand can be reduced significantly by controlled dehumidification with mechanical

  12. Closed-orbit correction using the new beam position monitor electronic of Elsa Bonn

    CERN Document Server

    Dietrich, J; Keil, J

    2000-01-01

    RF and digital electronics, developed at the Forschungszentrum Jülich/IKP were integrated to form the new beam position monitor (BPM) system at the Electron Stretcher Accelerator (ELSA) of the University of Bonn. With this system the preservation of the polarization level during acceleration was currently improved by a good correction of the closed-orbit. All BPM offsets relative to the magnetic quadrupole centers were determined by the method of beam-based alignment. The optics functions measured by the BPM system are in good agreement with theoretical predictions.

  13. Basis and algorithms applied in modern neutron flux monitoring equipment for WWER. Some results of its operation

    International Nuclear Information System (INIS)

    Alpatov, A. M.; Kamyshan, A. N.; Louzhnov, A. M.; Sokolov, I. V.

    2007-01-01

    The report presents the principle of operation and description of equipment complex for monitoring, control and protection by power, period, reactivity and local parameters of the core of WWER type reactor. The use in NFME of programmed computing means permitted on basis of signals from ex-core neutron detectors of working range, distributed over IC channel height, to realize operative non-inertia monitoring of mean axial power distribution shape in the core and its main characteristics (axial offset and axial non-uniformity coefficient). With regard for this and due to the use of information on position of control banks and on coolant temperature in the reactor vessel downcomer the equipment for power correction, eliminating the influence of the above factors on resulting signal and permitting to increase significantly the accuracy of power monitoring, was designed(Authors)

  14. Auditing of Monitoring and Respiratory Support Equipment in a Level III-C Neonatal Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Elena Bergon-Sendin

    2015-01-01

    Full Text Available Background. Random safety audits (RSAs are a safety tool but have not been widely used in hospitals. Objectives. To determine the frequency of proper use of equipment safety mechanisms in relation to monitoring and mechanical ventilation by performing RSAs. The study also determined whether factors related to the patient, time period, or characteristics of the area of admission influenced how the device safety systems were used. Methods. A prospective observational study was conducted in a level III-C Neonatal Intensive Care Unit (NICU during 2012. 87 days were randomly selected. Appropriate overall use was defined when all evaluated variables were correctly programmed in the audited device. Results. A total of 383 monitor and ventilator audits were performed. The Kappa coefficient of interobserver agreement was 0.93. The rate of appropriate overall use of the monitors and respiratory support equipment was 33.68%. Significant differences were found with improved usage during weekends, OR 1.85 (1.12–3.06, p=0.01, and during the late shift (3 pm to 10 pm, OR 1.59 (1.03–2.4, p=0.03. Conclusions. Equipment safety systems of monitors and ventilators are not properly used. To improve patient safety, we should identify which alarms are really needed and where the difficulties lie for the correct alarm programming.

  15. Automatic monitoring of the alignment and wear of vibration welding equipment

    Science.gov (United States)

    Spicer, John Patrick; Cai, Wayne W.; Chakraborty, Debejyo; Mink, Keith

    2017-05-23

    A vibration welding system includes vibration welding equipment having a welding horn and anvil, a host machine, a check station, and a welding robot. At least one displacement sensor is positioned with respect to one of the welding equipment and the check station. The robot moves the horn and anvil via an arm to the check station, when a threshold condition is met, i.e., a predetermined amount of time has elapsed or a predetermined number of welds have been completed. The robot moves the horn and anvil to the check station, activates the at least one displacement sensor, at the check station, and determines a status condition of the welding equipment by processing the received signals. The status condition may be one of the alignment of the vibration welding equipment and the wear or degradation of the vibration welding equipment.

  16. Comparative survey of site and personnel monitoring characteristics for operation of various types of diagnostic-X ray equipment

    International Nuclear Information System (INIS)

    Lyarskij, P.P.; Zol'nikova, N.I.

    1977-01-01

    Diagnostic X-ray machines in present use at medical facilities differ in design and operating parameters, this diversity producing, in turn, a variety of local radiological situations and levels of personnel exposure. Based on radiological safety characterization of working conditions, the authors present a breakdown of contemporary diagnostic X-ray equipment types, based on detailed examination of each group in terms of their associated site monitoring and dosimetry patterns. The paper reports data on personnel exposure levels not only as a function of equipment design and operating characteristics but also according to types of occupational activities for particular medical personnel groups (radiologists, surgeons, anesthesiologists, etc.). Included are health physics data for domestic and foreign X-ray equipment, levels of local and absorbed doses for radiologists, cardiovascular surgeons, neurosurgeons, urologists, traumatologists, anesthesiologists, etc. Measures are recommended for optimizing their activities from the standpoint of radiation safety. (author)

  17. Wireless Power Supply via Coupled Magnetic Resonance for on-line Monitoring Wireless Sensor of High-voltage Electrical Equipment

    DEFF Research Database (Denmark)

    Xingkui, Mao; Qisheng, Huang; Yudi, Xiao

    2016-01-01

    On-line monitoring of high-voltage electrical equipment (HV-EE) aiming to detect faults effectively has become crucial to avoid serious accidents. Moreover, highly reliable power supplies are the key component for the wireless sensors equipped in such on-line monitoring systems. Therefore......, in this paper, the wireless power supply via coupled magnetic resonance (MR-WPS) is proposed for powering the wireless sensor and the associated wireless sensor solution is also proposed. The key specifications of the MR-WPS working in switchgear cabinet with a harsh operation environment are analyzed...... power is able to be delivered to the wireless sensor through the designed MR-WPS, and therefore the theoretical analysis and design is verified....

  18. Ambient vibration characterization and monitoring of a rock slope close to collapse

    Science.gov (United States)

    Burjánek, Jan; Gischig, Valentin; Moore, Jeffrey R.; Fäh, Donat

    2018-01-01

    We analyse the ambient vibration response of Alpe di Roscioro (AdR), an incipient rock slope failure located above the village Preonzo in southern Switzerland. Following a major failure in May 2012 (volume ˜210 000 m3), the remaining unstable rock mass (˜140 000 m3) remains highly fractured and disrupted, and has been the subject of intensive monitoring. We deployed a small-aperture seismic array at the site shortly after the 2012 failure. The measured seismic response exhibited strong directional amplification (factors up to 35 at 3.5 Hz), higher than previously recorded on rock slopes. The dominant direction of ground motion was found to be parallel to the predominant direction of deformation and perpendicular to open fractures, reflecting subsurface structure of the slope. We then equipped the site with two semi-permanent seismic stations to monitor the seismic response with the goal of identifying changes caused by internal damage that may precede subsequent failure. Although failure has not yet occurred, our data reveal important variations in the seismic response. Amplification factors and resonant frequencies exhibit seasonal trends related (both directly and inversely) to temperature changes and are sensitive to freezing periods (resonant frequencies increase with temperature and during freezing). We attribute these effects to thermal expansion driving microcrack closure, in addition to ice formation, which increase fracture and bulk rock stiffness. We find the site response at AdR is linear over the measured range of weak input motions spanning two orders of magnitude. Our results further develop and refine ambient vibration methods used in rock slope hazard assessment.

  19. Spectrum correction algorithm for detectors in airborne radioactivity monitoring equipment NH-UAV based on a ratio processing method

    International Nuclear Information System (INIS)

    Cao, Ye; Tang, Xiao-Bin; Wang, Peng; Meng, Jia; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2015-01-01

    The unmanned aerial vehicle (UAV) radiation monitoring method plays an important role in nuclear accidents emergency. In this research, a spectrum correction algorithm about the UAV airborne radioactivity monitoring equipment NH-UAV was studied to measure the radioactive nuclides within a small area in real time and in a fixed place. The simulation spectra of the high-purity germanium (HPGe) detector and the lanthanum bromide (LaBr 3 ) detector in the equipment were obtained using the Monte Carlo technique. Spectrum correction coefficients were calculated after performing ratio processing techniques about the net peak areas between the double detectors on the detection spectrum of the LaBr 3 detector according to the accuracy of the detection spectrum of the HPGe detector. The relationship between the spectrum correction coefficient and the size of the source term was also investigated. A good linear relation exists between the spectrum correction coefficient and the corresponding energy (R 2 =0.9765). The maximum relative deviation from the real condition reduced from 1.65 to 0.035. The spectrum correction method was verified as feasible. - Highlights: • An airborne radioactivity monitoring equipment NH-UAV was developed to measure radionuclide after a nuclear accident. • A spectrum correction algorithm was proposed to obtain precise information on the detected radioactivity within a small area. • The spectrum correction method was verified as feasible. • The corresponding spectrum correction coefficients increase first and then stay constant

  20. Spectrum correction algorithm for detectors in airborne radioactivity monitoring equipment NH-UAV based on a ratio processing method

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Ye [Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016 (China); Tang, Xiao-Bin, E-mail: tangxiaobin@nuaa.edu.cn [Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016 (China); Jiangsu Key Laboratory of Nuclear Energy Equipment Materials Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016 (China); Wang, Peng; Meng, Jia; Huang, Xi; Wen, Liang-Sheng [Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016 (China); Chen, Da [Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016 (China); Jiangsu Key Laboratory of Nuclear Energy Equipment Materials Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016 (China)

    2015-10-11

    The unmanned aerial vehicle (UAV) radiation monitoring method plays an important role in nuclear accidents emergency. In this research, a spectrum correction algorithm about the UAV airborne radioactivity monitoring equipment NH-UAV was studied to measure the radioactive nuclides within a small area in real time and in a fixed place. The simulation spectra of the high-purity germanium (HPGe) detector and the lanthanum bromide (LaBr{sub 3}) detector in the equipment were obtained using the Monte Carlo technique. Spectrum correction coefficients were calculated after performing ratio processing techniques about the net peak areas between the double detectors on the detection spectrum of the LaBr{sub 3} detector according to the accuracy of the detection spectrum of the HPGe detector. The relationship between the spectrum correction coefficient and the size of the source term was also investigated. A good linear relation exists between the spectrum correction coefficient and the corresponding energy (R{sup 2}=0.9765). The maximum relative deviation from the real condition reduced from 1.65 to 0.035. The spectrum correction method was verified as feasible. - Highlights: • An airborne radioactivity monitoring equipment NH-UAV was developed to measure radionuclide after a nuclear accident. • A spectrum correction algorithm was proposed to obtain precise information on the detected radioactivity within a small area. • The spectrum correction method was verified as feasible. • The corresponding spectrum correction coefficients increase first and then stay constant.

  1. Enhancement of equipment services for Kozloduy NPP

    International Nuclear Information System (INIS)

    Schultz, Christophe

    2013-01-01

    Conclusion After 5 years of maintenance services, KNPP and AREVA have continuously intensified their partnership Close cooperation between KNPP, AREVA Local Office Engineers and OEM experts Involvement of sophisticated tools for diagnostics and condition monitoring Performance of engineering services and obsolescence evaluation Possibilities to perform equipment modernization of Electrical and IC equipment in future

  2. Facility effluent monitoring plan for the 2724-W Protective Equipment Decontamination Facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Lavey, G.H.

    1992-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1* for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation requires the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438**. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  3. Facility Effluent Monitoring Plan for the 2724-W Protective Equipment Decontamination Facility

    International Nuclear Information System (INIS)

    Carter, G.J.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1* for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updates as a minimum every three years

  4. Technology of Measuring equipment for Air Pollution. Development of Mobile Air Pollution monitoring system (LIDAR)

    International Nuclear Information System (INIS)

    Cha, Hyung Ki; Song, Ky Seok; Rhee, Young Joo; Kim, Duck Hyun; Yang, Ki Ho; Lee, Jong Min; Cha, Byung Heon; Lee, Kang Soo

    1999-01-01

    Most air pollution monitoring technologies accompany a time-consuming sample treatment process and provides pollution information only for a local area. Thus, they have a critical restriction in monitoring time-dependent pollution variation effectively over the wide range of area both in height and in width. LIDAR (Light detection and ranging) is a new technology to overcome such drawbacks of the existing pollution monitoring technologies and has long been investigated in the advanced countries. The goal of this project is to develop the mobile air pollution monitoring system and to apply the system to the detection of various pollutants, such as ozone, nitrogen dioxide, sulfur dioxide and aerosols

  5. Technology of Measuring equipment for Air Pollution. Development of Mobile Air Pollution monitoring system (LIDAR)

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Hyung Ki; Song, Ky Seok; Rhee, Young Joo; Kim, Duck Hyun; Yang, Ki Ho; Lee, Jong Min; Cha, Byung Heon; Lee, Kang Soo

    1999-01-01

    Most air pollution monitoring technologies accompany a time-consuming sample treatment process and provides pollution information only for a local area. Thus, they have a critical restriction in monitoring time-dependent pollution variation effectively over the wide range of area both in height and in width. LIDAR (Light detection and ranging) is a new technology to overcome such drawbacks of the existing pollution monitoring technologies and has long been investigated in the advanced countries. The goal of this project is to develop the mobile air pollution monitoring system and to apply the system to the detection of various pollutants, such as ozone, nitrogen dioxide, sulfur dioxide and aerosols.

  6. Long-term monitoring of soil gas fluxes with closed chambers using automated and manual systems

    Energy Technology Data Exchange (ETDEWEB)

    Scott, A.; Crichton, I.; Ball, B.C.

    1999-10-01

    The authors describe two gas sample collection techniques, each of which is used in conjunction with custom made automated or manually operated closed chambers. The automated system allows automatic collection of gas samples for simultaneous analysis of multiple trace gas efflux from soils, permitting long-term monitoring. Since the manual system is cheaper to produce, it can be replicated more than the automated and used to estimate spatial variability of soil fluxes. The automated chamber covers a soil area of 0.5 m{sup 2} and has a motor driven lid that remains operational throughout a range of weather conditions. Both systems use gas-tight containers of robust metal construction, which give good sample retention, thereby allowing long-term storage and convenience of transport from remote locations. The containers in the automated system are filled by pumping gas from the closed chamber via a multiway rotary valve. Stored samples from both systems are analyzed simultaneously for N{sub 2}O and CO{sub 2} using automated injection into laboratory-based gas chromatographs. The use of both collection systems is illustrated by results from a field experiment on sewage sludge disposal to land where N{sub 2}O fluxes were high. The automated gas sampling system permitted quantification of the marked temporal variability of concurrent N{sub 2}O and CO{sub 2} fluxes and allowed improved estimation of cumulative fluxes. The automated measurement approach yielded higher estimates of cumulative flux because integration of manual point-in-time observations missed a number of transient high-flux events.

  7. Node localization algorithm of wireless sensor networks for large electrical equipment monitoring application

    DEFF Research Database (Denmark)

    Chen, Qinyin; Hu, Y.; Chen, Zhe

    2016-01-01

    Node localization technology is an important technology for the Wireless Sensor Networks (WSNs) applications. An improved 3D node localization algorithm is proposed in this paper, which is based on a Multi-dimensional Scaling (MDS) node localization algorithm for large electrical equipment monito...

  8. Concept of diagnostic monitoring of condition of selected equipment for V-1 nuclear power plant

    International Nuclear Information System (INIS)

    Jaros, I.

    1981-01-01

    The vibroacoustic method based on picking up and processing vibrations, shocks and structural noise from the outer surface of equipment was chosen for testing the mechanical conditions of the reactor and of the main circulating pumps. The location of vibration pickups on the primary circuit components, their specifications, signal processing and evaluation are described. (M.D.)

  9. A New Approach to Detection of Systematic Errors in Secondary Substation Monitoring Equipment Based on Short Term Load Forecasting

    Directory of Open Access Journals (Sweden)

    Javier Moriano

    2016-01-01

    Full Text Available In recent years, Secondary Substations (SSs are being provided with equipment that allows their full management. This is particularly useful not only for monitoring and planning purposes but also for detecting erroneous measurements, which could negatively affect the performance of the SS. On the other hand, load forecasting is extremely important since they help electricity companies to make crucial decisions regarding purchasing and generating electric power, load switching, and infrastructure development. In this regard, Short Term Load Forecasting (STLF allows the electric power load to be predicted over an interval ranging from one hour to one week. However, important issues concerning error detection by employing STLF has not been specifically addressed until now. This paper proposes a novel STLF-based approach to the detection of gain and offset errors introduced by the measurement equipment. The implemented system has been tested against real power load data provided by electricity suppliers. Different gain and offset error levels are successfully detected.

  10. 40 CFR 60.2165 - What monitoring equipment must I install and what parameters must I monitor?

    Science.gov (United States)

    2010-07-01

    ... devices (or establish methods) for monitoring the value of the operating parameters used to determine... measure and record the values for these operating parameters at the frequencies indicated in table 2 of... a bag leak detection system as specified in paragraphs (b)(1) through (8) of this section. (1) You...

  11. 40 CFR 62.14690 - What monitoring equipment must I install and what parameters must I monitor?

    Science.gov (United States)

    2010-07-01

    ... monitoring the value of the operating parameters used to determine compliance with the operating limits listed in table 2 of this subpart. These devices (or methods) must measure and record the values for... subpart, you must install, calibrate, maintain, and continuously operate a bag leak detection system as...

  12. New Approach to Enhance an Effect of Condition Monitoring of Mid/Small Size Rotating Equipment in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Shin You Soo; Chang, Hee Seung [KHNP, Daejeon (Korea, Republic of)

    2016-05-15

    Condition monitoring for small and medium-size rotating equipment is mainly done by a patrol inspection and a vibration measurement. These methods are useful to recognize a significant change in a sound, temperature and vibration amplitude on the bearing housing. However, such a significant change shows an abnormal condition just before failure so that there is not much time to take a right action to recover. In other words, there is a severe damage when someone detects the phenomenon. These methods are good way to detect a flaw but too late to fix. It can't detect early recognition of defect To enhance the effect of condition monitoring and recognize a defect earlier, an integrated measurement including high band frequency analysis is required. It will be implemented at one of nuclear power plants in Korea as a pilot to verify an effect and applicability at nuclear power plants.

  13. 40 CFR 63.7927 - What are my inspection and monitoring requirements for closed vent systems and control devices?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 13 2010-07-01 2010-07-01 false What are my inspection and monitoring... Pollutants: Site Remediation Closed Vent Systems and Control Devices § 63.7927 What are my inspection and... temperature at the inlet of the catalyst bed, the hourly average temperature at the outlet of the catalyst bed...

  14. Improvement of nuclear power plant monitor and control equipment. Computer application backfitting

    International Nuclear Information System (INIS)

    Hayakawa, H.; Kawamura, A.; Suto, O.; Kinoshita, Y.; Toda, Y.

    1985-01-01

    This paper describes the application of advanced computer technology to existing Japanese Boiling Water Reactor (BWR) nuclear power plants for backfitting. First we review the background of the backfitting and the objectives of backfitting. A feature of backfitting such as restrictions and constraints imposed by the existing equipment are discussed and how to overcome these restrictions by introduction of new technology such as highly efficient data transmission using multiplexing, and compact space saving computer systems are described. Role of the computer system in reliable NPS are described with a wide spectrum of TOSHIBA backfitting computer system application experiences. (author)

  15. Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation dose

    Directory of Open Access Journals (Sweden)

    I. P. Stamat

    2016-01-01

    Full Text Available This paper provides review of equipment and methodology for measurement of photon radiation dose; analysis of possible reasons for considerable deviation between the Russian Federation population annual effective external irradiation doses and the relevant average global value. Data on Rospotrebnadzor bodies dosimetry equipment used for measurement of gamma radiation dose are collected and systematized. Over 60 kinds of dosimeters are used for monitoring of population external irradiation doses. Most of dosimeters used in the country have gas-discharge detectors (Geiger-Mueller counters, minor biochemical annunciators, etc. which have higher total values of own background level and of space radiation response than the modern dosimeters with scintillation detectors. This feature of dosimeters is apparently one of most plausible reasons of a bit overstating assessment of population external irradiation doses. The options for specification of population external irradiation doses assessment are: correction of gamma radiation dose measurement results with consideration of dosimeters own background level and space radiation response, introduction of more up-to-date dosimeters with scintillation detectors, etc. The most promising direction of research in verification of population external irradiation doses assessment is account of dosimetry equipment.

  16. Leakage localization with an acoustic array that covers a wide area for pipeline leakage monitoring in a closed space

    Energy Technology Data Exchange (ETDEWEB)

    Park, Choon Su [Center for Safety Measurements, Division of Metrology for Quality of Life, Korea Research institute of Standards and Science, Daejeon (Korea, Republic of); Jeon, Jong Hoon [Hyundai Heavy Industry Co.,Ltd., Ulsan (Korea, Republic of); Park, Jin Ho [Korea Atomiv Energy Institute, Daejeon (Korea, Republic of)

    2013-10-15

    It is of great importance to localize leakages in complex pipelines for assuring their safety. A sensor array that can detect where leakages occur enables us to monitor a wide area with a relatively low cost. Beam forming is a fast and efficient algorithm to estimate where sources are, but it is generally made use of in free field condition. In practice, however, many pipelines are placed in a closed space for the purpose of safety and maintenance. This leads us to take reflected waves into account to the beam forming for interior leakage localization. Beam power distribution of reflected waves in a closed space is formulated, and spatial average is introduced to suppress the effect of reflected waves. Computer simulations and experiments ensure how the proposed method is effective to localize leakage in a closed space for structural health monitoring.

  17. IEEE Std 1205-1993: IEEE guide for assessing, monitoring, and mitigating aging effects on Class 1E equipment used in nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    The guidelines are provided for assessing, monitoring, and mitigating degradation of Class 1E equipment used in nuclear power generating stations due to aging. The methods described can be used to identify the performance capability of Class 1E equipment beyond its qualified life. A discussion of stressors and aging mechanisms is included. If aging considerations have been satisfactorily addressed through other means (e.g., equipment qualification), then use of this guide may not be warranted. For some equipment, only partial application of this guide may be warranted

  18. Waste assaying and radiation monitoring equipment at the waste management centre of NPP Leningrad

    Directory of Open Access Journals (Sweden)

    Šokčić-Kostić Marina

    2006-01-01

    Full Text Available The waste accumulated in the past at the Nuclear Power Plant Leningrad has to be sorted and packed in an optimal way. In the area of waste treatment and management, the completeness and quality of direct monitoring are of the outmost importance for the validity of, and confidence in, both practicable waste management options and calculations of radiological impacts. Special monitoring systems are needed for this purpose. Consistent with the scale of work during the waste treatment procedures and the complexity of the plant data have to be collected from characteristic parts in various treatment stages. To combine all the information, a tracking procedure is needed during the waste treatment process to characterize the waste for interim and/or final disposal. RWE NUKEM GmbH has developed special customer-tailored systems which fulfill the specifications required by plant operation and by the authorities.

  19. Monitoring and measurement of variables - assurance of observability and controllability of the reactor equipment

    International Nuclear Information System (INIS)

    Durnev, V.N.; Mitelman, M.G.

    2001-01-01

    The presentation presents main conclusions on the basis of analysis of the existing situation with assurance of observability and controllability of the reactor installation. A methodology of classification of variables of the controlled object state and proposals on selection and substantiation of measurement and inspection monitoring techniques is given. Main problems associated with assurance of observability and controllability of the reactor installation are presented for various operation modes. (Authors)

  20. Process and equipment for monitoring flux distribution in a nuclear reactor outside the core

    International Nuclear Information System (INIS)

    Graham, K.F.; Gopal, R.

    1977-01-01

    This concerns the monitoring system for axial flux distribution during the whole load operating range lying outside the core of, for example, a PWR. Flux distribution cards can be produced continuously. The core is divided into at least three sections, which are formed by dividing it at right angles to the longitudinal axis, and the flux is measured outside the core using adjacent detectors. Their output signals are calibrated by amplifiers so that the load distribution in the associated sections is reproduced. A summation of the calibrated output signals and the formation of a mean load signal takes place in summing stages. For monitoring, this is compared with a value which corresponds to the maximum permissible load setting. Apart from this the position of the control rods in the core can be taken into account by multiplication of the mean load signals by suitable peak factors. The distribution of monitoring positions or the position of the detectors can be progressive or symmetrical along the axis. (DG) 891 HP [de

  1. Real-Time Monitoring and Prediction of the Pilot Vehicle System (PVS) Closed-Loop Stability

    Science.gov (United States)

    Mandal, Tanmay Kumar

    Understanding human control behavior is an important step for improving the safety of future aircraft. Considerable resources are invested during the design phase of an aircraft to ensure that the aircraft has desirable handling qualities. However, human pilots exhibit a wide range of control behaviors that are a function of external stimulus, aircraft dynamics, and human psychological properties (such as workload, stress factor, confidence, and sense of urgency factor). This variability is difficult to address comprehensively during the design phase and may lead to undesirable pilot-aircraft interaction, such as pilot-induced oscillations (PIO). This creates the need to keep track of human pilot performance in real-time to monitor the pilot vehicle system (PVS) stability. This work focused on studying human pilot behavior for the longitudinal axis of a remotely controlled research aircraft and using human-in-the-loop (HuIL) simulations to obtain information about the human controlled system (HCS) stability. The work in this dissertation is divided into two main parts: PIO analysis and human control model parameters estimation. To replicate different flight conditions, this study included time delay and elevator rate limiting phenomena, typical of actuator dynamics during the experiments. To study human control behavior, this study employed the McRuer model for single-input single-output manual compensatory tasks. McRuer model is a lead-lag controller with time delay which has been shown to adequately model manual compensatory tasks. This dissertation presents a novel technique to estimate McRuer model parameters in real-time and associated validation using HuIL simulations to correctly predict HCS stability. The McRuer model parameters were estimated in real-time using a Kalman filter approach. The estimated parameters were then used to analyze the stability of the closed-loop HCS and verify them against the experimental data. Therefore, the main contribution of

  2. Plant equipment integrity monitoring and diagnosing method and device therefor, plant equipment maintenance and inspection time determining method and device therefor, as well as nuclear power plant

    International Nuclear Information System (INIS)

    Kato, Takahiko; Ando, Masashi; Osumi, Katsumi; Horiuchi, Tetsuo; Asakura, Yamato; Akamine, Kazuhiko.

    1995-01-01

    The present invention can accurately forecast a time for occurrence of troubles of plant equipments in contact with recycling water, to conduct its maintenance and inspection before occurrence of the troubles. Namely, change of water quality in plant equipments caused by corrosion of recycling water occurred in constitutional parts of the plant equipments is measured. The time upon occurrence of the troubles of the plant equipments to corrosion of the recycling water is forecast based on the measured value. A time till the occurrence of the change of water quality after starting the use of the plant equipments is calculated based on the measured value. The calculated time is compared with a correlation between the time of occurrence of the troubles after starting the use of the plant equipments and the time of occurrence of change of the water quality, to forecast the time of occurrence of the troubles. Preferably, electroconductivity and pH of recycling water in the inside or at the exit of the plant equipments are measured as an object for the measurement of change of water quality. (I.S.)

  3. Effective solutions for monitoring the electrostatic separation of metal and plastic granular waste from electric and electronic equipment.

    Science.gov (United States)

    Senouci, Khouira; Medles, Karim; Dascalescu, Lucian

    2013-02-01

    The variability of the quantity and purity of the recovered materials is a serious drawback for the application of electrostatic separation technologies to the recycling of granular wastes. In a series of previous articles we have pointed out how capability and classic control chart concepts could be employed for better mastering the outcome of such processes. In the present work, the multiple exponentially weighted moving average (MEWMA) control chart is introduced and shown to be more effective than the Hotelling T2 chart for monitoring slow varying changes in the electrostatic separation of granular mixtures originating from electric and electronic equipment waste. The operation of the industrial process was simulated by using a laboratory roll-type electrostatic separator and granular samples resulting from shredded electric cable wastes. The 25 tests carried out during the observation phase enabled the calculation of the upper and lower control limits for the two control charts considered in the present study. The 11 additional tests that simulated the monitoring phase pointed out that the MEWMA chart is more effective than Hotelling's T(2) chart in detecting slow varying changes in the outcome of a process. As the reverse is true in the case of abrupt alterations of monitored process performances, simultaneous usage of the two control charts is strongly recommended. While this study focused on a specific electrostatic separation process, using the MEWMA chart together with the well known Hotelling's T(2) chart should be applicable to the statistical control of other complex processes in the field of waste processing.

  4. Evaluation of sampling equipment for RCRA [Resource Conservation and Recovery Act] monitoring in a deep unconfined aquifer

    International Nuclear Information System (INIS)

    Kasper, R.B.; Serkowski, J.A.

    1988-02-01

    Acceptable sampling devices identified include gas-operated bladder pumps and bailers constructed of nonreactive materials. In arid portions of the western United States, depths to ground water, which are often greater than 100 feet, make the use of bailers extremely time consuming. The efficiency of gas-operated bladder pumps decreases with depth, and special design and construction is often needed to accommodate higher gas pressures. Commercially available sampling pumps were evaluated for their suitability as sampling and purging equipment for installation in monitoring wells in a deep, unconfined aquifer. The test was conducted in a well where the depth to ground water was 340 feet. The objective was to identify equipment capable of discharge rates suitable for sampling (∼0.025 gpm) and, if possible, for purging (>1 gpm). The potential for physical or chemical alteration of the water sample was evaluated from literature sources and not specifically tested. Four positive-displacement pumps were tested, consisting of two bladder pumps, a gas-driven piston pump, and a mechanically-driven pump. All pumps could be installed in a 2-inch diameter well, although this was not important for the planned application. 4 refs., 1 tab

  5. Peculiarities of the Continuous Glucose Monitoring Data Stream and Their Impact on Developing Closed-Loop Control Technology

    OpenAIRE

    Kovatchev, Boris; Clarke, William

    2008-01-01

    Therapeutic advances in type 1 diabetes (T1DM) are currently focused on developing a closed-loop control system using a continuous glucose monitor (CGM), subcutaneous insulin delivery, and a control algorithm. Because a CGM assesses blood glucose indirectly (and therefore often inaccurately), it limits the effectiveness of the controller. In order to improve the quality of CGM data, a series of analyses are suggested. These analyses evaluate and compensate for CGM errors, assess risks associa...

  6. Investigation of monitoring technologies for heat transfer corrosion in reprocessing equipment

    International Nuclear Information System (INIS)

    Tsukatani, I.; Kiuchi, K.

    2004-01-01

    Two types of in-situ monitoring techniques using electrical resistance methods were developed for estimating the wall thinning of heat transfer tubes used in evaporators for Purex process on commercial reprocessing plants. The corrosion rate is accelerated with oxidizer ions formed by the thermal decomposition of nitric acid under heat flux. An in-situ corrosion sensor was developed for estimating the corrosion rate of heat transfer tubes using miniature heat transfer tube specimens under heat flux control. It is possible to simulate the heating condition as same as heat transfer tubes. The applicability was evaluated by setting it in gas-liquid separator in a mock-up evaporator for acid recovery. The sensitivity of electric resistance methods is increased with decreasing the residual thickness of probe tube. The other is the electrical potential drop method using direct current so-called the field signature method. It is applicable to estimate the corrosiveness of reprocessing nitric acid by setting it on the drain tube in evaporator. The sensitivity to the thinning rate of tubes wall machined artificially was obtained within ±10% to the wall thickness. It has the non-sensitive region nearly 0.1mm up to begin working. The practical applicability has been also evaluated by setting it in a mock-up evaporator. (author)

  7. Ultra sensitive sea water radioactivity monitoring system. Autonomous low power consumption equipped with wireless data communication

    International Nuclear Information System (INIS)

    Bonet, H.; Debauche, A.; Lellis, C. de; Adam, V.; Lacroix, J.P.; Put, P. van

    2003-01-01

    Following the recognition of their usefulness by the States and the scientific community, the automatic water monitoring networks were developed again to be able to measure sea water. For that purpose they had to be fully autonomous, have low power consumption (solar panels power supply), use wireless communicating (satellite, GSM, Radio) and be very sensitive (few Bq/m 3 ). It is important to note that radioactivity detection in sea has many constraints: The detection system sensitivity must be very high because of the dilution factor of the ocean. The analysis method has to be adapted: the detection of very low levels of artificial contamination is made difficult due to the natural radioactivity in seawater (i.e., more than 10 kBq of 40 K/m 3 ). The system has to be completely autonomous, 'wireless'. Additional conventional measuring probes must be connected to the system to increase its interest (pH, t deg, salinity, position, meteorology). The system maintenance must be very limited (1/year). Wind and corrosion resistance must be high. The probe must be installed on a buoy. Moreover, some improvements are needed to allow: Amplification Gain drifts due to NaI sensitivity to t deg to be compensated. Net peak area computation in a specific energy range. Interference correction to prevent false alarms due to natural radiation. Very long counting time. (author)

  8. Radiological Monitoring Equipment For Real-Time Quantification Of Area Contamination In Soils And Facility Decommissioning

    International Nuclear Information System (INIS)

    M. V. Carpenter; Jay A. Roach; John R Giles; Lyle G. Roybal

    2005-01-01

    The environmental restoration industry offers several systems that perform scan-type characterization of radiologically contaminated areas. The Idaho National Laboratory (INL) has developed and deployed a suite of field systems that rapidly scan, characterize, and analyze radiological contamination in surface soils. The base system consists of a detector, such as sodium iodide (NaI) spectrometers, a global positioning system (GPS), and an integrated user-friendly computer interface. This mobile concept was initially developed to provide precertification analyses of soils contaminated with uranium, thorium, and radium at the Fernald Closure Project, near Cincinnati, Ohio. INL has expanded the functionality of this basic system to create a suite of integrated field-deployable analytical systems. Using its engineering and radiation measurement expertise, aided by computer hardware and software support, INL has streamlined the data acquisition and analysis process to provide real-time information presented on wireless screens and in the form of coverage maps immediately available to field technicians. In addition, custom software offers a user-friendly interface with user-selectable alarm levels and automated data quality monitoring functions that validate the data. This system is deployed from various platforms, depending on the nature of the survey. The deployment platforms include a small all-terrain vehicle used to survey large, relatively flat areas, a hand-pushed unit for areas where maneuverability is important, an excavator-mounted system used to scan pits and trenches where personnel access is restricted, and backpack- mounted systems to survey rocky shoreline features and other physical settings that preclude vehicle-based deployment. Variants of the base system include sealed proportional counters for measuring actinides (i.e., plutonium-238 and americium-241) in building demolitions, soil areas, roadbeds, and process line routes at the Miamisburg Closure

  9. Monitoring of biological odour filtration in closed environments with olfactometry and an electronic nose

    NARCIS (Netherlands)

    Willers, H.C.; Gijsel, de P.; Ogink, N.W.M.; Amico, D' A.; Martinelli, E.; Natale, Di C.; Ras, van N.; Waarde, van der J.

    2004-01-01

    Air treatment with a compact biological membrane filter, and air quality monitoring with an electronic nose were tested in the laboratory on air from a cage containing six mice. Additional analyses of air to and from the filter were performed using olfactometry and ammonia and hydrogen sulphide gas

  10. Workshop 3.5: Closing the gap between exposure and effects in monitoring studies

    Science.gov (United States)

    Tillitt, Donald E.; Papoulias, Diana M.

    2003-01-01

    A major challenge to contaminant monitoring programs is the selection of an appropriate suite of measurements for assessing exposure and effects. Early monitoring programs relied solely on residue analysis to detect the organochlorine compounds that were in use at that time. A shift to the use of more transient, less persistent chemicals required that a new set of tools be developed to determine if an organism had been exposed. This led to the development of cellular and biochemical assays that could indicate the presence of these types of chemicals in biota and the environment. However, it was recognized that measures of contaminant presence alone were insufficient to assess the health of biota. As a result, considerable research began to be directed toward development of diagnostic tools for measuring chemical effects in fish and wildlife. Today, contaminant monitoring programs follow a paradigm for study design that emphasizes not only the use of measures of exposure, but also measures of effect. Using data from our monitoring and research studies for hormonally active substances, we discuss a variety of metrics of exposure and effects and their application to specific chemicals, and the current information gaps. We conclude that although several bioindicators of exposure and effect have been promoted and used, to date there continues to be a poor association between cause and effect for endocrine active substances. In part, this is due to the limited number of diagnostic tools that are available and to a lack of basic toxicological information concerning toxicokinetics and mechanisms of action of hormonally active chemicals in fish and wildlife species. In the foreseeable future, both tissue and environmental residue data, despite the many limitations, will continue to be an important component of monitoring programs for hormonally active chemicals as we continue to develop and validate more specific bioindicators of exposure and effects.

  11. Airborne particle monitoring with urban closed-circuit television camera networks and a chromatic technique

    International Nuclear Information System (INIS)

    Kolupula, Y R; Jones, G R; Deakin, A G; Spencer, J W; Aceves-Fernandez, M A

    2010-01-01

    An economic approach for the preliminary assessment of 2–10 µm sized (PM10) airborne particle levels in urban areas is described. It uses existing urban closed-circuit television (CCTV) surveillance camera networks in combination with particle accumulating units and chromatic quantification of polychromatic light scattered by the captured particles. Methods for accommodating extraneous light effects are discussed and test results obtained from real urban sites are presented to illustrate the potential of the approach

  12. Dynamics of a Tularemia Outbreak in a Closely Monitored Free-Roaming Population of Wild House Mice.

    Science.gov (United States)

    Dobay, Akos; Pilo, Paola; Lindholm, Anna K; Origgi, Francesco; Bagheri, Homayoun C; König, Barbara

    2015-01-01

    Infectious disease outbreaks can be devastating because of their sudden occurrence, as well as the complexity of monitoring and controlling them. Outbreaks in wildlife are even more challenging to observe and describe, especially when small animals or secretive species are involved. Modeling such infectious disease events is relevant to investigating their dynamics and is critical for decision makers to accomplish outbreak management. Tularemia, caused by the bacterium Francisella tularensis, is a potentially lethal zoonosis. Of the few animal outbreaks that have been reported in the literature, only those affecting zoo animals have been closely monitored. Here, we report the first estimation of the basic reproduction number R0 of an outbreak in wildlife caused by F. tularensis using quantitative modeling based on a susceptible-infected-recovered framework. We applied that model to data collected during an extensive investigation of an outbreak of tularemia caused by F. tularensis subsp. holarctica (also designated as type B) in a closely monitored, free-roaming house mouse (Mus musculus domesticus) population in Switzerland. Based on our model and assumptions, the best estimated basic reproduction number R0 of the current outbreak is 1.33. Our results suggest that tularemia can cause severe outbreaks in small rodents. We also concluded that the outbreak self-exhausted in approximately three months without administrating antibiotics.

  13. Dynamics of a Tularemia Outbreak in a Closely Monitored Free-Roaming Population of Wild House Mice.

    Directory of Open Access Journals (Sweden)

    Akos Dobay

    Full Text Available Infectious disease outbreaks can be devastating because of their sudden occurrence, as well as the complexity of monitoring and controlling them. Outbreaks in wildlife are even more challenging to observe and describe, especially when small animals or secretive species are involved. Modeling such infectious disease events is relevant to investigating their dynamics and is critical for decision makers to accomplish outbreak management. Tularemia, caused by the bacterium Francisella tularensis, is a potentially lethal zoonosis. Of the few animal outbreaks that have been reported in the literature, only those affecting zoo animals have been closely monitored. Here, we report the first estimation of the basic reproduction number R0 of an outbreak in wildlife caused by F. tularensis using quantitative modeling based on a susceptible-infected-recovered framework. We applied that model to data collected during an extensive investigation of an outbreak of tularemia caused by F. tularensis subsp. holarctica (also designated as type B in a closely monitored, free-roaming house mouse (Mus musculus domesticus population in Switzerland. Based on our model and assumptions, the best estimated basic reproduction number R0 of the current outbreak is 1.33. Our results suggest that tularemia can cause severe outbreaks in small rodents. We also concluded that the outbreak self-exhausted in approximately three months without administrating antibiotics.

  14. Exploitation of process knowledge for the monitoring and closed loop control of fermentation processes; Erschliessen von Prozesswissen fuer das Monitoring und die Regelung von Fermentationsprozessen

    Energy Technology Data Exchange (ETDEWEB)

    Grote, Bianca; Hitzmann, Bernd [Hohenheim Univ., Stuttgart (Germany). FG Prozessanalytik und Getreidetechnologie; John, Jinu Mulamoottil

    2011-07-01

    The significance of process knowledge for the monitoring and closed loop control of biotechnical processes is demonstrated. An important problem of the development of chemometric models is the expense of calibration measurements required to calculate values of process variables from unselective measurements. To reduce this expense a method was developed which uses a dynamic process model instead of measurements. As an example the chemometric modeling will be discussed of a baker's yeast cultivation measuring fluorescence spectra and estimating biomass, glucose, and ethanol concentrations. We demonstrate the exploitation of process knowledge during an Escherichia colifermentation for the closed loop control of glucose concentration by using an extended Kalman filter. Here the effective dead time and the measurement noise will be compensated by this method. The glucose set point is 0.05g/L. The yield of the process exceeds by far that of batch fermentations. (orig.)

  15. The Design and Implementation of Smart Monitoring System for Large-Scale Railway Maintenance Equipment Cab Based on ZigBee Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Hairui Wang

    2014-06-01

    Full Text Available In recent years, organizations use IEEE 802.15.4 and ZigBee technology to deliver solution in variety areas including home environment monitoring. ZigBee technology has advantages on low-cost, low power consumption and self-forming. With the rapid expansion of the Internet, there is the requirement for remote monitoring large-scale railway maintenance equipment cab. This paper discusses the disadvantages of the existing smart monitoring system, and proposes a solution. A ZigBee wireless sensor network smart monitoring system and Wi-Fi network is integrated through a home gateway to increase the system flexibility. At the same time the home gateway cooperated with a pre- processing system provide a flexible user interface, and the security and safety of the smart monitoring system. To testify the efficiency of the proposed system, the temperature and humidity sensors and light sensors have developed and evaluated in the smart monitoring system.

  16. The Design and Implementation of Smart Monitoring System for Large-Scale Railway Maintenance Equipment Cab Based on ZigBee Wireless Sensor Network

    OpenAIRE

    Hairui Wang; Junfu Yu

    2014-01-01

    In recent years, organizations use IEEE 802.15.4 and ZigBee technology to deliver solution in variety areas including home environment monitoring. ZigBee technology has advantages on low-cost, low power consumption and self-forming. With the rapid expansion of the Internet, there is the requirement for remote monitoring large-scale railway maintenance equipment cab. This paper discusses the disadvantages of the existing smart monitoring system, and proposes a solution. A ZigBee wireless senso...

  17. Extracellular pH monitoring for use in closed-loop vagus nerve stimulation

    Science.gov (United States)

    Cork, Simon C.; Eftekhar, Amir; Mirza, Khalid B.; Zuliani, Claudio; Nikolic, Konstantin; Gardiner, James V.; Bloom, Stephen R.; Toumazou, Christofer

    2018-02-01

    Objective. Vagal nerve stimulation (VNS) has shown potential benefits for obesity treatment; however, current devices lack physiological feedback, which limit their efficacy. Changes in extracellular pH (pHe) have shown to be correlated with neural activity, but have traditionally been measured with glass microelectrodes, which limit their in vivo applicability. Approach. Iridium oxide has previously been shown to be sensitive to fluctuations in pH and is biocompatible. Iridium oxide microelectrodes were inserted into the subdiaphragmatic vagus nerve of anaesthetised rats. Introduction of the gut hormone cholecystokinin (CCK) or distension of the stomach was used to elicit vagal nerve activity. Main results. Iridium oxide microelectrodes have sufficient pH sensitivity to readily detect changes in pHe associated with both CCK and gastric distension. Furthermore, a custom-made Matlab script was able to use these changes in pHe to automatically trigger an implanted VNS device. Significance. This is the first study to show pHe changes in peripheral nerves in vivo. In addition, the demonstration that iridium oxide microelectrodes are sufficiently pH sensitive as to measure changes in pHe associated with physiological stimuli means they have the potential to be integrated into closed-loop neurostimulating devices.

  18. Multiple Constraints Based Robust Matching of Poor-Texture Close-Range Images for Monitoring a Simulated Landslide

    Directory of Open Access Journals (Sweden)

    Gang Qiao

    2016-05-01

    Full Text Available Landslides are one of the most destructive geo-hazards that can bring about great threats to both human lives and infrastructures. Landslide monitoring has been always a research hotspot. In particular, landslide simulation experimentation is an effective tool in landslide research to obtain critical parameters that help understand the mechanism and evaluate the triggering and controlling factors of slope failure. Compared with other traditional geotechnical monitoring approaches, the close-range photogrammetry technique shows potential in tracking and recording the 3D surface deformation and failure processes. In such cases, image matching usually plays a critical role in stereo image processing for the 3D geometric reconstruction. However, the complex imaging conditions such as rainfall, mass movement, illumination, and ponding will reduce the texture quality of the stereo images, bringing about difficulties in the image matching process and resulting in very sparse matches. To address this problem, this paper presents a multiple-constraints based robust image matching approach for poor-texture close-range images particularly useful in monitoring a simulated landslide. The Scale Invariant Feature Transform (SIFT algorithm was first applied to the stereo images for generation of scale-invariate feature points, followed by a two-step matching process: feature-based image matching and area-based image matching. In the first feature-based matching step, the triangulation process was performed based on the SIFT matches filtered by the Fundamental Matrix (FM and a robust checking procedure, to serve as the basic constraints for feature-based iterated matching of all the non-matched SIFT-derived feature points inside each triangle. In the following area-based image-matching step, the corresponding points of the non-matched features in each triangle of the master image were predicted in the homologous triangle of the searching image by using geometric

  19. Recommendations on the choice of gas analysis equipment for systems of continuous monitoring and accounting of emissions from thermal power plants

    Science.gov (United States)

    Kondrat'eva, O. E.; Roslyakov, P. V.; Burdyukov, D. A.; Khudolei, O. D.; Loktionov, O. A.

    2017-10-01

    According to Federal Law no. 219-FZ, dated July 21, 2014, all enterprises that have a significant negative impact on the environment shall continuously monitor and account emissions of harmful substances into the atmospheric air. The choice of measuring equipment that is included in continuous emission monitoring and accounting systems (CEM&ASs) is a complex technical problem; in particular, its solution requires a comparative analysis of gas analysis systems; each of these systems has its advantages and disadvantages. In addition, the choice of gas analysis systems for CEM&ASs should be maximally objective and not depend on preferences of separate experts and specialists. The technique of choosing gas analysis equipment that was developed in previous years at Moscow Power Engineering Institute (MPEI) has been analyzed and the applicability of the mathematical tool of a multiple criteria analysis to choose measuring equipment for the continuous emission monitoring and accounting system have been estimated. New approaches to the optimal choice of gas analysis equipment for systems of the continuous monitoring and accounting of harmful emissions from thermal power plants have been proposed, new criteria of evaluation of gas analysis systems have been introduced, and weight coefficients have been determined for these criteria. The results of this study served as a basis for the Preliminary National Standard of the Russian Federation "Best Available Technologies. Automated Systems of Continuous Monitoring and Accounting of Emissions of Harmful (Polluting) Substances from Thermal Power Plants into the Atmospheric Air. Basic Requirements," which was developed by the Moscow Power Engineering Institute, National Research University, in cooperation with the Council of Power Producers and Strategic Electric Power Investors Association and the All-Russia Research Institute for Materials and Technology Standardization.

  20. The control, monitor, and alarm system for the ICT equipment of the ASTRI SST-2M telescope prototype for the Cherenkov Telescope Array

    Science.gov (United States)

    Gianotti, Fulvio; Fioretti, Valentina; Tanci, Claudio; Conforti, Vito; Tacchini, Alessandro; Leto, Giuseppe; Gallozzi, Stefano; Bulgarelli, Andrea; Trifoglio, Massimo; Malaguti, Giuseppe; Zoli, Andrea

    2014-07-01

    ASTRI is an Italian flagship project whose first goal is the realization of an end-to-end telescope prototype, named ASTRI SST-2M, for the Cherenkov Telescope Array (CTA). The prototype will be installed in Italy during Fall 2014. A second goal will be the realization of the ASTRI/CTA mini-array which will be composed of seven SST-2M telescopes placed at the CTA Southern Site. The Information and Communication Technology (ICT) equipment necessary to drive the infrastructure for the ASTRI SST-2M prototype is being designed as a complete and stand-alone computer center. The design goal is to obtain basic ICT equipment that might be scaled, with a low level of redundancy, for the ASTRI/CTA mini-array, taking into account the necessary control, monitor and alarm system requirements. The ICT equipment envisaged at the Serra La Nave observing station in Italy, where the ASTRI SST-2M telescope prototype will operate, includes computers, servers and workstations, network devices, an uninterruptable power supply system, and air conditioning systems. Suitable hardware and software tools will allow the parameters related to the behavior and health of each item of equipment to be controlled and monitored. This paper presents the proposed architecture and technical solutions that integrate the ICT equipment in the framework of the Observatory Control System package of the ASTRI/CTA Mini- Array Software System, MASS, to allow their local and remote control and monitoring. An end-toend test case using an Internet Protocol thermometer is reported in detail.

  1. Calibration of the A.E.E. Winfrith whole body monitor equipment with sodium-24 solution in a polythene man-phantom

    International Nuclear Information System (INIS)

    Peabody, C.O.; Speight, R.G.; Passant, F.H.

    1964-04-01

    Results are presented for the sensitivity of the existing Winfrith Whole Body Monitor equipment when used for measurement of sodium-24 activity in solution in a polythene man-phantom. The relationship is discussed between these results and those expected for the sodium-24 produced in a human body by accidental neutron irradiation. Estimates are made of the additional contribution of chlorine-38 activity at various times after whole body irradiation. (author)

  2. Yeasts from Scarlet ibises (Eudocimus ruber): A focus on monitoring the antifungal susceptibility of Candida famata and closely related species.

    Science.gov (United States)

    Brilhante, Raimunda Sâmia Nogueira; Silva, Aline Lobão da; Monteiro, Frederico Ozanan Barros; Guedes, Glaucia Morgana de Melo; Sales, Jamille Alencar; Oliveira, Jonathas Sales de; Maia Junior, José Erisvaldo; Miranda, Stefânia Araújo; Sidrim, José Júlio Costa; Alencar, Lucas Pereira de; Castelo-Branco, Débora Souza Collares Maia; Cordeiro, Rossana de Aguiar; Pereira Neto, Waldemiro de Aquino; Rocha, Marcos Fábio Gadelha

    2017-10-01

    This study aimed to identify yeasts from the gastrointestinal tract of scarlet ibises (Eudocimus ruber) and from plant material collected from the environment where they live. Then, the isolates phenotypically identified as Candida famata were submitted to molecular identification of their closely related species and evaluated for their antifungal susceptibility and possible resistance mechanisms to antifungal drugs. Cloacal swabs from 20 scarlet ibises kept in captivity at Mangal das Garças Park (Brazil), pooled stool samples (n = 20) and samples of trunks and hollow of trees (n = 20) obtained from their enclosures were collected. The samples were seeded on Sabouraud agar supplemented with chloramphenicol. The 48 recovered isolates were phenotypically identified as 15 Candida famata, 13 Candida catenulata, 2 Candida intermedia, 1 Candida lusitaniae, 2 Candida guilliermondii, 1 Candida kefyr, 1 Candida amapae, 1 Candida krusei, 8 Trichosporon spp., and 4 Rhodotorula spp. The C. famata isolates were further identified as 3 C. famata, 8 Debaryomyces nepalensis, and 4 C. palmioleophila. All C. famata and C. palmioleophila were susceptible to caspofungin and itraconazole, while one D. nepalensis was resistant to fluconazole and voriconazole. This same isolate and another D. nepalensis had lower amphotericin B susceptibility. The azole resistant strain had an increased efflux of rhodamine 6G and an alteration in the membrane sterol content, demonstrating multifactorial resistance mechanism. Finally, this research shows that scarlet ibises and their environment harbor C. famata and closely related species, including antifungal resistant isolates, emphasizing the need of monitoring the antifungal susceptibility of these yeast species. © The Author 2017. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Protection of control and monitoring equipment from electromagnetic noise in the 67 MJ, 50 kV capacitor bank

    Energy Technology Data Exchange (ETDEWEB)

    Galakhov, I V; Gasheev, A S; Grusin, I A; Gudov, S N; Kuz` michev, Yu P; Murugov, V M; Osin, V A; Pankratov, V I; Pegoev, I N [All-Russian Scientific Research Inst. of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    A discharge of the 67 MJ and 50 kV capacitor bank used as a pulsed power system for flashlamp pumping of ISKRA-5`s high-power iodine laser, involves control and diagnostic equipment being subjected to significant electromagnetic fields and electrical interference that will further develop through conductive circuits. The paper describes and validates design approaches to the grounding system, signal carriage and decoupling circuits that would result in lower interference both for the capacitor bank`s control and diagnostics systems. A summary is also given of the ten-years` practice in operating the control and diagnostics equipment during the facility experiments. (author). 1 tab., 3 refs.

  4. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment developed for the renewal of the network of stations automatic monitoring environmental radiation of the Generalitat of Catalunya

    International Nuclear Information System (INIS)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2014-01-01

    The renewal of the automatic environmental radiation surveillance network of the Generalitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. the monitors use scintillation crystals, either Na(TI) or LaBr 3 (Ce) and currently, there are 3 types of equipment water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentration for some isotopes. (Author)

  5. Field Evaluation of Cereal Combine Harvesters Processing Losses on JD-955 and JD-1165 Combines Equipped with Grain Loss Monitor

    Directory of Open Access Journals (Sweden)

    M.R Mostofi Sarkari

    2014-09-01

    Full Text Available Grain loss monitors are installed on combine harvester and make it possible to measure grain loss on different parts of the combine. The instrument permits the operator to adjust a proper ground speed to keep grain loss within an acceptable range. In this study a loss monitoring system was implemented to measure grain losses continuously on straw walker and sieves. Two grain loss monitors (KEE and TeeJet were installed behind the straw walker and the sieves of JD-955 and JD-1165 combine harvesters. Harvesting performance parameters such as combine total and processing losses were then measured. To evaluate the precision and accuracy of the instruments, the measured and monitored losses were compared and investigated. The results of a two-year research showed that the average processing loss of the combine harvesters with 10-12% grain moisture content and 750 rpm drum speed was 0.82% which is whitin the acceptable range recommended by ASAE Standard No. S343.3. Furthermore, there was no significant difference between the measured and monitored values of processing loss.

  6. Nuclear electronic equipment for control and monitoring panel. Procedure guide for on-site tests of nuclear reactor instruments

    International Nuclear Information System (INIS)

    1975-10-01

    By the use of a procedure for on-site testing of nuclear reactor instruments it should be possible to judge their ability to guarantee the reactor safety and availability at the moment of divergence or during operation. Such a procedure must therefore be created as a work implement for the quick and reliable installation of electronic devices necessary for nuclear reactor control and supervision. A standard document is proposed for this purpose, allowing a ''test programme'' to be set up before the equipment is installed on the site [fr

  7. Soil CO2 efflux measurement network by means of closed static chambers to monitor volcanic activity at Tenerife, Canary Islands

    Science.gov (United States)

    Amonte, Cecilia; García-Merino, Marta; Asensio-Ramos, María; Melián, Gladys; García-Hernández, Rubén; Pérez, Aaron; Hernández, Pedro A.; Pérez, Nemesio M.

    2017-04-01

    Tenerife (2304 km2) is the largest of the Canary Islands and has developed a central volcanic complex (Cañadas edifice), that started to grow about 3.5 My ago. Coeval with the construction of the Cañadas edifice, shield basaltic volcanism continued until the present along three rift zones oriented NW-SE, NE-SW and NS (hereinafter referred as NW, NE and NS respectively). Main volcanic historical activity has occurred along de NW and NE rift-zones, although summit cone of Teide volcano, in central volcanic complex, is the only area of the island where surface geothermal manifestations are visible. Uprising of deep-seated gases occurs along the aforementioned volcanic structures causing diffuse emissions at the surface environment of the rift-zones. In the last 20 years, there has been considerable interest in the study of diffuse degassing as a powerful tool in volcano monitoring programs. Diffuse degassing studies are even more important volcanic surveillance tool at those volcanic areas where visible manifestations of volcanic gases are absent. Historically, soil gas and diffuse degassing surveys in volcanic environments have focused mainly on CO2 because it is, after water vapor, the most abundant gas dissolved in magma. One of the most popular methods used to determine CO2 fluxes in soil sciences is based on the absorption of CO2 through an alkaline medium, in its solid or liquid form, followed by gravimetric, conductivity, or titration analyses. In the summer of 2016, a network of 31 closed static chambers was installed, covering the three main structural zones of Tenerife (NE, NW and NS) as well as Cañadas Caldera with volcanic surveillance porpoises. 50 cc of 0.1N KOH solution is placed inside the chamber to absorb the CO2 released from the soil. The solution is replaced weekly and the trapped CO2 is then analyzed at the laboratory by titration. The are expressed as weekly integrated CO2 efflux values. The CO2 efflux values ranged from 3.2 to 12.9 gṡm-2

  8. Improving the Efficiency of Administrative Decision-Making when Monitoring Reliability and Safety of Oil and Gas Equipment

    Directory of Open Access Journals (Sweden)

    Zemenkova Maria

    2016-01-01

    Full Text Available Methodology of rapid assessment of reliability index was developed based on system analysis of technological parameters. Within functioning of on-line monitoring system of reliability index of industrial facility this method allows to increase efficiency of making managerial decisions on technical and preventive maintenance. The technique is based on the analysis of technological parameters of operational modes of pipeline transport facilities registered by dispatcher controls. The created technique can be used by the operating, research, design institutes and oil and gas transport enterprises when declaring industrial safety. The received mathematical models allow federal services of supervision, the independent expert organizations to predict the development of reliability in the registered block of dispatching data either in real time mode, or taking into account the dynamics of service conditions of the object.

  9. Nuclear electronic equipment for control and monitoring boards. Specifications and test methods of direct current period meters

    International Nuclear Information System (INIS)

    Roquefort, Henri; Chapelot; Ramard; Tardif; Tournier; Vaux

    1973-11-01

    After a few words of introduction, mention of the main notations used and the definition of certain terms, the field of application of the document is outlined and a list of references given. The main specifications of electronic 'direct current period meter' subassemblies for the monitoring, control and safety of nuclear reactors are then defined and the corresponding test methods described. The apparatus measures on a logarithmic scale the neutron fluence rate of a reactor by means of an ionisation chamber and supplies 'period' data relative to the fluence rate variation in time. The specifications and test methods are given for the different components: logarithmic amplifier, time derivative unit, threshold releases, high tension supply for ionisation chamber, auxiliary circuits and finally the complete period meter. (author) [fr

  10. Direct current linear measurement sub-assembly data and test methods. Nuclear electronic equipment for control and monitoring panel

    International Nuclear Information System (INIS)

    1977-12-01

    The M.C.H./M.E.N.T.3 document is concerned with sub-assemblies intended for measuring on a linear scale the neutron fluence rate or radiation dose rate when connected with nuclear detectors working in current. The symbols used are described. Some definitions and a bibliography are given. The main characteristics of direct current linear measurement sub-assemblies are then described together with corresponding test methods. This type of instrument indicates on a linear scale the level of a direct current applied to its input. The document reviews linear sub-assemblies for general purpose applications, difference amplifiers for monitoring, and averaging amplifiers. The document is intended for electronics manufacturers, designers, persons participating in acceptance trials and plant operators [fr

  11. On-Line Enrichment Monitor (OLEM) Phase II Final Report Techniques and Equipment for Safeguards at Gas Centrifuge Enrichment Plants

    Energy Technology Data Exchange (ETDEWEB)

    Younkin, James R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Garner, James R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-04-01

    Over the last five years, OLEM has been a collaborative development effort involving the IAEA, LANL, ORNL, URENCO, and the NNSA. The collective team has completed the following: design and modelling, software development, hardware integration, testing with the ORNL UF6 Flow Loop, a field trial at the Urenco facility in Almelo, the Netherlands, and a Demonstration at the Urenco USA facility in Eunice, New Mexico. This combined effort culminated in the deployment of several OLEM collection nodes in Iran. These OLEM units are one unattended monitoring system component of the Joint Comprehensive Plan of Action allowing the International Atomic Energy Agency to verify Iran’s compliance with the enrichment production aspects of the agreement.

  12. Two-Year Operational Evaluation Of A Consumer Electronics-Based Data Acquisition System For Equipment Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Van Hoy, Blake W. [ORNL; Phillips, Larry D. [ORNL; Wetherington Jr, G Randall [ORNL; Damiano, Brian [ORNL; Green, Craig [ORNL

    2017-04-01

    Oak Ridge National Laboratory (ORNL) has performed a two-year evaluation of the performance of an in-house developed consumer electronics-based data acquisition system (DAS). The main advantage of this approach compared to conventional instrumentation grade systems is cost; instrument grade data acquisition systems average costs range from $800 to $2,000 per channel compared to a range of $200 - $400 per channel for a consumer electronics-based system. The DAS is operated as a full-time in-situ vibration monitor. The resulting data stream is streamed over the ORNL network, at an aggregate rate of approximately 2 megabytes/s, to a Linux server. The server includes the capability to implement event-triggered data stores, as well as real-time files for the implementation of continuous display monitoring of the spectra. Detailed spectral analysis is performed post event. The DAS is installed on a large industrial chiller and cooling water pump associated with ORNL’s Titan supercomputer. These mechanical systems include rotating components that operate at fundamental frequencies within the range of 30 Hz to over 3 KHz. Evaluation of the DAS data over a two-year operating period leads to the conclusion that for many industrial processes this system could form the basis for a cost effective means of obtaining operating health data in real time from rotating machinery. The deployment has also shown that the DAS technology is reliable. Furthermore, because the cost of the DAS is low, the other significant advantage of this approach is that the DAS can be deployed in a dedicated manner and operated on a full-time basis.

  13. Customization of home closed-loop insulin delivery in adult patients with type 1 diabetes, assisted with structured remote monitoring: the pilot WP7 Diabeloop study.

    Science.gov (United States)

    Benhamou, Pierre Yves; Huneker, Erik; Franc, Sylvia; Doron, Maeva; Charpentier, Guillaume

    2018-06-01

    Improvement in closed-loop insulin delivery systems could result from customization of settings to individual needs and remote monitoring. This pilot home study evaluated the efficacy and relevance of this approach. A bicentric clinical trial was conducted for 3 weeks, using an MPC-based algorithm (Diabeloop Artificial Pancreas system) featuring five settings designed to modulate the reactivity of regulation. Remote monitoring was ensured by expert nurses with a web platform generating automatic Secured Information Messages (SIMs) and with a structured procedure. Endpoints were glucose metrics and description of impact of monitoring on regulation parameters. Eight patients with type 1 diabetes (six men, age 41.8 ± 11.4 years, HbA1c 7.7 ± 1.0%) were included. Time spent in the 70-180 mg/dl range was 70.2% [67.5; 76.9]. Time in hypoglycemia < 70 mg/dl was 2.9% [2.1; 3.4]. Eleven SIMs led to phone intervention. Original default settings were modified in all patients by the intervention of the nurses. This pilot trial suggests that the Diabeloop closed-loop system could be efficient regarding metabolic outcomes, whereas its telemedical monitoring feature could contribute to enhanced efficacy and safety. This study is registered at ClinicalTrials.gov with trial registration number NCT02987556.

  14. Novel XRD technique and equipment for in-situ monitoring of phase transformations in lithium batteries during cycling

    International Nuclear Information System (INIS)

    Nikolov, J.; Howlett, P.

    2002-01-01

    Full text: Safe, rechargeable batteries utilising a lithium metal electrode have not been realised due to phenomena, which occur on the lithium surface during the cycling of a battery. Lithium ion conduction inhomogeneities through the surface film give rise to uneven deposition of lithium, which can result in short circuits. The large potential increase in energy density that the use of the lithium electrode represents makes the nature of the surface film of interest to battery researchers. The lithium surface is highly reactive, particularly in the case of electrodes with a rough surface deposit. This presents difficulties to researchers hoping to obtain representative measurements of the lithium surface and requires the use of environmental sample chambers and in-situ techniques. X-ray diffraction techniques have been used to probe changes in cathode materials (typically transition metal oxides) for lithium batteries, but to our knowledge has not been successfully used to study changes taking place on the lithium surface during cycling. We present early results from work we have undertaken to develop a technique for characterising the surface film on lithium battery electrodes. The instrumentation was set-up as follows. An XRD was fitted with an INEL CPS 120 position sensitive detector (PSD), multilayer mirror and environmental chamber. The latter was specially developed in our laboratory for the purpose of these experiments. The lithium cells were sealed in laminated foil. Cycled and uncycled cells were investigated. Different radiation sources were used (Cu, Co and Cr). The in-situ measurements aiming at monitoring the phase transitions of cycled/uncycled cells at different angles (including grazing angles) in time were carried out in both transmission and reflection mode. Copyright (2002) Australian X-ray Analytical Association Inc

  15. Evaluation of indirect blood pressure monitoring in awake and anesthetized red-tailed hawks (Buteo jamaicensis): effects of cuff size, cuff placement, and monitoring equipment.

    Science.gov (United States)

    Zehnder, Ashley M; Hawkins, Michelle G; Pascoe, Peter J; Kass, Philip H

    2009-09-01

    To compare Doppler and oscillometric methods of indirect arterial blood pressure (IBP) with direct arterial measurements in anesthetized and awake red-tailed hawks. Prospective, randomized, blinded study. Six, sex unknown, adult red-tailed hawks. Birds were anesthetized and IBP measurements were obtained by oscillometry (IBP-O) and Doppler (IBP-D) on the pectoral and pelvic limbs using three cuffs of different width based on limb circumference: cuff 1 (20-30% of circumference), cuff 2 (30-40%), and cuff 3 (40-50%). Direct arterial pressure measurements were obtained from the contralateral superficial ulnar artery. Indirect blood pressure measurements were compared to direct systolic arterial pressure (SAP) and mean arterial pressure (MAP) during normotension and induced states of hypotension and hypertension. Measurements were also obtained in awake, restrained birds. Three-way anova, linear regression and Bland-Altman analyses were used to evaluate the IBP-D data. Results are reported as mean bias (95% confidence intervals). The IBP-O monitor reported errors during 54% of the measurements. Indirect blood pressure Doppler measurements were most accurate with cuff 3 and were comparable to MAP with a bias of 2 (-9, 13 mmHg). However, this cuff consistently underestimated SAP with a bias of 33 (19, 48 mmHg). Variability in the readings within and among birds was high. There was no significant difference between sites of cuff placement. Awake birds had SAP, MAP and diastolic arterial pressure that were 56, 43, and 38 mmHg higher than anesthetized birds. Indirect blood pressure (oscillometric) measurements were unreliable in red-tailed hawks. Indirect blood pressure (Doppler) measurements were closer to MAP measurements than SAP measurements. There was slightly better agreement with the use of cuff 3 on either the pectoral or pelvic limbs. Awake, restrained birds have significantly higher arterial pressures than those under sevoflurane anesthesia.

  16. Towards a closed-loop cochlear implant system: application of embedded monitoring of peripheral and central neural activity.

    Science.gov (United States)

    Mc Laughlin, Myles; Lu, Thomas; Dimitrijevic, Andrew; Zeng, Fan-Gang

    2012-07-01

    Although the cochlear implant (CI) is widely considered the most successful neural prosthesis, it is essentially an open-loop system that requires extensive initial fitting and frequent tuning to maintain a high, but not necessarily optimal, level of performance. Two developments in neuroscience and neuroengineering now make it feasible to design a closed-loop CI. One development is the recording and interpretation of evoked potentials (EPs) from the peripheral to the central nervous system. The other is the embedded hardware and software of a modern CI that allows recording of EPs. We review EPs that are pertinent to behavioral functions from simple signal detection and loudness growth to speech discrimination and recognition. We also describe signal processing algorithms used for electric artifact reduction and cancellation, critical to the recording of electric EPs. We then present a conceptual design for a closed-loop CI that utilizes in an innovative way the embedded implant receiver and stimulators to record short latency compound action potentials ( ~1 ms), auditory brainstem responses (1-10 ms) and mid-to-late cortical potentials (20-300 ms). We compare EPs recorded using the CI to EPs obtained using standard scalp electrodes recording techniques. Future applications and capabilities are discussed in terms of the development of a new generation of closed-loop CIs and other neural prostheses.

  17. Long-term hydrothermal temperature and pressure monitoring equipped with a Kuroko cultivation apparatus on the deep-sea artificial hydrothermal vent at the middle Okinawa Trough

    Science.gov (United States)

    Masaki, Y.; Nozaki, T.; Saruhashi, T.; Kyo, M.; Sakurai, N.; Yokoyama, T.; Akiyama, K.; Watanabe, M.; Kumagai, H.; Maeda, L.; Kinoshita, M.

    2017-12-01

    The middle Okinawa Trough, located along the Ryukyu- arc on the margin of the East China Sea, has several active hydrothermal fields. From February to March 2016, Cruise CK16-01 by D/V Chikyu targeted the Iheya-North Knoll and southern flank of the Iheya Minor Ridge to comprehend sub-seafloor geological structure and polymetallic sulfide mineralization. In this cruise, we installed two Kuroko cultivation apparatuses equipped with P/T sensors, flowmeter and load cell to monitor pressure, temperature and flow rate of hydrothermal fluid discharged from the artificial hydrothermal vent together with weight of hydrothermal precipitate. During Cruise KR16-17 in January 2017, two cultivation cells with sensor loggers were successfully recovered by ROV Kaiko MK-IV and R/V Kairei. We report these physical sensor data obtained by more than 10 months monitoring at two deep-sea artificial hydrothermal vents through many first and challenging operations.Hole C9017B at southern flank of the Iheya Minor Ridge (water depth of 1,500 mbsl), fluid temperature was constant ca. 75 ºC for 5 months from the beginning of monitoring. Then temperature gradually decrease to be 40 ºC. In November 2016, temperature and pressure suddenly dropped and quickly recovered due to the disturbance of subseafloor hydrology, induced by another drilling operation at Hole C9017A which is 10.8 meters northeastward from Hole C9017B during Cruise CK16-05. Temperature data exhibit conspicuous periodic 12.4hour cycles and this is attributable to oceanic tidal response. The amplitude of temperature variations increased along with decline of the temperature variations increased along with decline of the temperature. The average flow rate was 67 L/min for 9 hours from the onset of monitoring.Hole C9024A at the Iheya-North Knoll (water depth of 1,050 msl), the maximum temperature reached 308 ºC, which is similar to the maximum value of 311 ºC obtained from the ROV thermometer. The average flow rate was 289 L

  18. Equipment considerations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Trace or ultratrace analyses require that the HPLC equipment used, including the detector, be optimal for such determinations. HPLC detectors are discussed at length in Chapter 4; discussion here is limited to the rest of the equipment. In general, commercial equipment is adequate for trace analysis; however, as the authors approach ultratrace analysis, it becomes very important to examine the equipment thoroughly and optimize it, where possible. For this reason they will review the equipment commonly used in HPLC and discuss the optimization steps. Detectability in HPLC is influenced by two factors (1): (a) baseline noise or other interferences that lead to errors in assigning the baseline absorbance; (b) peak width. 87 refs

  19. Development of an integrated closed loop control system with virtual reality monitoring for Prototype Robotic Articulated System (PRAS)

    International Nuclear Information System (INIS)

    Rastogi, Naveen; Dutta, Pramit; Gotewal, K.K.

    2015-01-01

    The Prototype Robotic Articulated System (PRAS) is a servo driven 4 degrees of freedom robotic arm capable of handling of upto 5 kg payload. A virtual reality based monitoring application has been developed in blender and was intergrated with the control system to read the joint values of the robotic arm at 10Hz and update the CAD model to visualize the robotic operations remotely. This paper presents the design details and implementation results of the integrated control system for PRAS

  20. Monitoring the hand hygiene compliance of health care workers in a general intensive care unit: Use of continuous closed circle television versus overt observation.

    Science.gov (United States)

    Brotfain, Evgeni; Livshiz-Riven, Ilana; Gushansky, Alexander; Erblat, Alexander; Koyfman, Leonid; Ziv, Tomer; Saidel-Odes, Lisa; Klein, Moti; Borer, Abraham

    2017-08-01

    A variety of hand hygiene monitoring programs (HHMPs) have come into use in hospitals throughout the world. In the present study, we compare continuous closed circle television (CCTV) with overt observation for monitoring the hand hygiene compliance of health care workers (HCWs) in a general intensive care unit (GICU). This is a cross-sectional and comparative study. In this study, we use a novel hand hygiene CCTV monitoring system for hand hygiene performance monitoring. The study population incorporated all the GICU HCWs, including registered nurses, staff physicians, and auxiliary workers. All HCWs of our GICU were observed, including ICU registered nurses, ICU staff physicians, and auxiliary workers participated in the present study. Overall, each observer team did 50 sessions in each arm of the study. Total number of hand hygiene opportunities was approaching 500 opportunities. The compliance rates when only overt observations were performed was higher than when only covert observations were performed with a delta of approximately 10% (209 out of 590 [35.43%] vs 130 out of 533 [24.39%]; P hand hygiene. However, there is no clear basis for incorporating a CCTV observation modality into a health care system that already operates an overt observation program. We have shown that CCTV methodology records a different distribution of opportunities for performing hand hygiene and of actual performances of hand hygiene compared with overt observation. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. Development of a system for monitoring and diagnosis using Fuzzy logic in control valves of laboratory test equipment of Experimental Center Aramar

    International Nuclear Information System (INIS)

    Porto Junior, Almir Carlos Soares

    2014-01-01

    The question of components reliability, specifically process control valves, has become an important issue to be investigated in nuclear power plants and other areas such as refinery or offshore oil rig, considering the safety and life extension of the plant. The development of non intrusive monitoring and diagnostic method allows the identification of defects in components of the plant during normal operation. The objective of this dissertation is to present an analysis and diagnosis of control valves of a steam plant part that simulates the secondary circuit of a pressurized water reactor. This installation is part of propulsion equipment testing laboratory of the Brazilian Navy, at Ipero-SP. The methodology for design is based on graphical analysis of two parameters, the valve air pressure actuator and the displacement of the valve plug. These data are extracted by a smart positioner, part of Delta V™ Automation System. An analysis is implemented in detecting anomalies by an approach using Expert Systems by the technique of fuzzy logic. Once the basic measures of control valves are taken, it is possible to detect symptoms of failure, leakage, friction, damage, etc. The monitoring and diagnostic system has been designed in MATLAB® version 2009 th by the complement 'Fuzzy Logic Toolbox'. It is a noninvasive technique. Thus, it is possible to know what is happening with the chosen components, just analyzing the parameters of the valve. The software called ValveLink® (developed by Emerson) receives signals from hardware component (intelligent positioner) installed next to the control valve. These signals (electrical current) are transformed into information which are used input parameters: air pressure valve actuator and valve plug displacement. With the use of fuzzy logic, these parameters are interpreted. They suffer inferences by rules written by experts in valves. After these inferences, the information is processed and sent as output signals

  2. In-situ thermoelectric temperature monitoring and "Closed-loop integrated control" system for concentrator photovoltaic-thermoelectric hybrid receivers

    Science.gov (United States)

    Rolley, Matthew H.; Sweet, Tracy K. N.; Min, Gao

    2017-09-01

    This work demonstrates a new technique that capitalizes on the inherent flexibility of the thermoelectric module to provide a multifunctional platform, and exhibits a unique advantage only available within CPV-TE hybrid architectures. This system is the first to use the thermoelectric itself for hot-side temperature feedback to a PID control system, needing no additional thermocouple or thermistor to be attached to the cell - eliminating shading, and complex mechanical designs for mounting. Temperature measurement accuracy and thermoelectric active cooling functionality is preserved. Dynamic "per-cell" condition monitoring and protection is feasible using this technique, with direct cell-specific temperature measurement accurate to 1°C demonstrated over the entire experimental range. The extrapolation accuracy potential of the technique was also evaluated.

  3. Automatic Web-Based, Radio-Network System To Monitor And Control Equipment For Investigating Gas Flux At Water - Air Interfaces

    Science.gov (United States)

    Duc, N. T.; Silverstein, S.; Wik, M.; Beckman, P.; Crill, P. M.; Bastviken, D.; Varner, R. K.

    2015-12-01

    Aquatic ecosystems are major sources of greenhouse gases (GHG). Robust measurements of natural GHG emissions are vital for evaluating regional to global carbon budgets and for assessing climate feedbacks on natural emissions to improve climate models. Diffusive and ebullitive (bubble) transport are two major pathways of gas release from surface waters. To capture the high temporal variability of these fluxes in a well-defined footprint, we designed and built an inexpensive automatic device that includes an easily mobile diffusive flux chamber and a bubble counter, all in one. Besides a function of automatically collecting gas samples for subsequent various analyses in the laboratory, this device utilizes low cost CO2 sensor (SenseAir, Sweden) and CH4 sensor (Figaro, Japan) to measure GHG fluxes. To measure the spatial variability of emissions, each of the devices is equipped with an XBee module to enable a local radio communication DigiMesh network for time synchronization and data readout at a server-controller station on the lakeshore. Software of this server-controller is operated on a low cost Raspberry Pi computer which has a 3G connection for remote monitoring - controlling functions from anywhere in the world. From field studies in Abisko, Sweden in summer 2014 and 2015, the system has resulted in measurements of GHG fluxes comparable to manual methods. In addition, the deployments have shown the advantage of a low cost automatic network system to study GHG fluxes on lakes in remote locations.

  4. Analysis of pelvic movement in the elderly during walking using a posture monitoring system equipped with a triaxial accelerometer and a gyroscope.

    Science.gov (United States)

    Ishigaki, Norio; Kimura, Teiji; Usui, Yuki; Aoki, Kaoru; Narita, Nobuyo; Shimizu, Masayuki; Hara, Kazuo; Ogihara, Nobuhide; Nakamura, Koichi; Kato, Hiroyuki; Ohira, Masayoshi; Yokokawa, Yoshiharu; Miyoshi, Kei; Murakami, Narumichi; Okada, Shinpei; Nakamura, Tomokazu; Saito, Naoto

    2011-06-03

    The incidence of falls in the elderly is increasing with the aging of society and is becoming a major public health issue. From the viewpoint of prevention of falls, it is important to evaluate the stability of the gait in the elderly people. The pelvic movement, which is a critical factor for walking stability, was analyzed using a posture monitoring system equipped with a triaxial accelerometer and a gyroscope. The subjects were 95 elderly people over 60 years of age. The criteria for instability were open-eye standing on one leg for 15s or less, and 11s or more on 3m timed up and go test. Forty subjects who did not meet both of these criteria comprised the stable group, and the remaining 55 subjects comprised the unstable group. Pelvic movement during walking was compared between the two groups. The angle, angular velocity, and acceleration were analyzed based on the wave shape derived from the device worn around the second sacral. The results indicated that pelvic movement was lower in all three directions in the unstable group compared to the stable group, and the changes in the pelvic movement during walking in unstable elderly people were also reduced. This report is the first to evaluate pelvic movement by both a triaxial accelerometer and a triaxial gyroscope simultaneously. The characteristics of pelvic movement during walking can be applied in screening to identify elderly people with instability, which is the main risk factor associated with falls. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Neurodevelopmental and body composition outcomes in children with congenital hypothyroidism treated with high-dose initial replacement and close monitoring.

    Science.gov (United States)

    Albert, Benjamin B; Heather, Natasha; Derraik, José G B; Cutfield, Wayne S; Wouldes, Trecia; Tregurtha, Sheryl; Mathai, Sarah; Webster, Dianne; Jefferies, Craig; Gunn, Alistair J; Hofman, Paul L

    2013-09-01

    Despite newborn screening and early levothyroxine replacement, there are continued reports of mild neurocognitive impairment in children with congenital hypothyroidism (CHT). In Auckland, New Zealand, cases are identified by a neonatal screening program with rapid institution of high-dose levothyroxine replacement (10-15 μg/kg·d), producing prompt normalization of thyroid function. Subsequently, frequent monitoring and dose alterations are performed for 2 years. We aimed to assess whether the Auckland treatment strategy prevents impairment of intellectual and motor development. This study encompassed all children with CHT born in 1993-2006 in Auckland and their siblings. Neurocognitive assessments included the following: 1) intelligence quotient via Weschler Preschool and Primary Scale of Intelligence III or Weschler Intelligence Scale for Children IV; 2) Movement Assessment Battery for Children; and 3) Beery Developmental Test of Visual-Motor Integration. Body composition was assessed by dual-energy x-ray absorptiometry. Forty-four CHT cases and 53 sibling controls aged 9.6 ± 3.9 years were studied. Overall intelligence quotient was similar among CHT cases and controls (95.2 vs 98.6; P = .20), and there were also no differences in motor function. Severity of CHT did not influence outcome, but greater time to normalize free T4 was associated with worse motor balance. There were no differences in anthropometry or body composition between groups. These findings suggest that a strategy of rapidly identifying and treating infants with CHT using high-dose levothyroxine replacement is associated with normal intellectual and motor development. The subtle negative impact on motor function associated with time to normalize free T4 levels is consistent with benefit from rapid initial correction.

  6. Legal provisions governing liquid effluents radiological monitoring

    International Nuclear Information System (INIS)

    Gans, I.; Ruehle, H.

    1985-01-01

    The KTA rule 1504 for radiological monitoring of liquid effluents from nuclear installations is explained. As there are no such rules published to date for establishments handling isotopes, some criteria are discussed which in the future ought to form part of a practical guide for liquid effluents monitoring in isotope handling installations. Monitoring measures described refer to liquid effluents from transfer containers, auxiliary cooling equipment, turbine buildings, main cooling installations, and waste air discharges from closed-circuit cooling systems. (DG) [de

  7. Nuclear power generating station equipment qualification method and apparatus

    International Nuclear Information System (INIS)

    Fero, A.H.; Potochnik, L.M.; Riling, R.W.; Semethy, K.F.

    1990-01-01

    This patent describes a method of monitoring an object piece of qualified equipment in a nuclear power plant. It comprises providing a first passive mimic means for mimicking the effect of radiation received by the object piece on the object piece; providing a second mimic means for mimicking the effect of a thermal history of the object piece on the object piece and mounting the first passive mimic means and the second mimic means in close proximity to the object piece

  8. Overall Equipment Effectiveness Implementation Criteria

    Science.gov (United States)

    Abramova, I. G.; Abramov, D. A.

    2018-01-01

    This article documents the methods applied in production control technics specifically focused on commonly used parameter OEE (Overall Equipment Effectiveness). The indicators of extensive and intensive use of equipment are considered. Their appointment this is comparison in the same type of production within the industry and comparison of single-type and / or different types of equipment in terms of capacity. However, it is shown that there is no possibility of revealing the reasons for the machine’s operation: productive / unproductive, with disturbances. Therefore, in the article reveals the approaches to calculating the indicator characterizing the direct operation of the equipment. The Machine Load coefficient is approaching closely to the indicator of the efficiency of the use of equipment. Methods analysis is proceeded through the historically applied techniques such as “Stopwatch” and “Motion” studies. Was performed the analysis of the efficiency index of OEE equipment using the comparable indexes performance of equipment in the Russian practice. An important indicator of OEE contains three components. The meaning of each of them reflects historically applicable indicators. The value of the availability of equipment indicator is close to the value of the equipment extensibility index. The value of the indicator of the efficiency of work can be compared with the characteristic of the capacity of the equipment and the indicator of the quality level can meet the requirements for compliance with the manufacturing technology. Shown that the sum of the values of the coefficient of “Availability” of the equipment and the value of the “Factor of compaction of working hours” are one. As well as the total value of the indicator “level of quality” and the coefficient of marriage given in the result unit. The measurability of the indicators makes it possible to make a prediction about efficiency of the equipment.

  9. [Hydrotherapy equipment].

    Science.gov (United States)

    Tsibikov, V B; Ragozin, S I; Mikheeva, L V

    1985-01-01

    A flow-chart is developed demonstrating the relation between medical and prophylactic institutions within the organizational structure of the rehabilitation system and main types of rehabilitation procedures. In order to ascertain the priority in equipping rehabilitation services with adequate hardware the special priority criterion is introduced. The highest priority is assigned to balneotherapeutic and fangotherapeutic services. Based on the operation-by-operation analysis of clinical processes related to service and performance of balneologic procedures the preliminary set of clinical devices designed for baths, basins and showers in hospitals and rehabilitation departments is defined in a generalized form.

  10. XMM-NEWTON MONITORING OF THE CLOSE PRE-MAIN-SEQUENCE BINARY AK SCO. EVIDENCE OF TIDE-DRIVEN FILLING OF THE INNER GAP IN THE CIRCUMBINARY DISK

    Energy Technology Data Exchange (ETDEWEB)

    Gomez de Castro, Ana Ines [S. D. Astronomia y Geodesia and Instituto de Matematica Interdisciplinar, Fac. de CC Matematicas, Universidad Complutense, E-28040 Madrid (Spain); Lopez-Santiago, Javier [Departamento de Astrofisica, Fac de CC Fisicas, Universidad Complutense, E-28040 Madrid (Spain); Talavera, Antonio [European Space Astronomy Center, Villanueva de la Canada, E-28691, Madrid (Spain); Sytov, A. Yu.; Bisikalo, D. [Institute of Astronomy of the Russian Academy of Sciences, Pyatnitskaya St. 48, 109017 Moscow (Russian Federation)

    2013-03-20

    AK Sco stands out among pre-main-sequence binaries because of its prominent ultraviolet excess, the high eccentricity of its orbit, and the strong tides driven by it. AK Sco consists of two F5-type stars that get as close as 11 R{sub *} at periastron passage. The presence of a dense (n{sub e} {approx} 10{sup 11} cm{sup -3}) extended envelope has been unveiled recently. In this article, we report the results from an XMM-Newton-based monitoring of the system. We show that at periastron, X-ray and UV fluxes are enhanced by a factor of {approx}3 with respect to the apastron values. The X-ray radiation is produced in an optically thin plasma with T {approx} 6.4 Multiplication-Sign 10{sup 6} K and it is found that the N{sub H} column density rises from 0.35 Multiplication-Sign 10{sup 21} cm{sup -2} at periastron to 1.11 Multiplication-Sign 10{sup 21} cm{sup -2} at apastron, in good agreement with previous polarimetric observations. The UV emission detected in the Optical Monitor band seems to be caused by the reprocessing of the high-energy magnetospheric radiation on the circumstellar material. Further evidence of the strong magnetospheric disturbances is provided by the detection of line broadening of 278.7 km s{sup -1} in the N V line with Hubble Space Telescope/Space Telescope Imaging Spectrograph. Numerical simulations of the mass flow from the circumbinary disk to the components have been carried out. They provide a consistent scenario with which to interpret AK Sco observations. We show that the eccentric orbit acts like a gravitational piston. At apastron, matter is dragged efficiently from the inner disk border, filling the inner gap and producing accretion streams that end as ring-like structures around each component of the system. At periastron, the ring-like structures come into contact, leading to angular momentum loss, and thus producing an accretion outburst.

  11. Close range photogrammetry and machine vision

    CERN Document Server

    Atkinson, KB

    1996-01-01

    This book presents the methodology, algorithms, techniques and equipment necessary to achieve real time digital photogrammetric solutions, together with contemporary examples of close range photogrammetry.

  12. Cryogenic equipment

    International Nuclear Information System (INIS)

    Leger, L.; Javellaud, J.; Caro, C.; Gilguy, R.; Testard, O.

    1966-06-01

    The cryostats presented here were built from standard parts; this makes it possible to construct a great variety of apparatus at minimum cost. The liquid nitrogen and helium reservoirs were designed so as to reduce losses to a minimum, and so as to make the cryostats as autonomous as possible. The experimental enclosure which is generally placed in the lower part of the apparatus requires a separate study in every case. Furthermore, complete assemblies such as transfer rods, isolated traps and high vacuum valves, were designed with a similar regard for the economic aspects and for the need for standardization. This equipment thus satisfies a great variety of experimental needs; it is readily adaptable and the consumptions of helium and liquid nitrogen are very low. (authors) [fr

  13. X-ray equipment

    International Nuclear Information System (INIS)

    Redmayne, I.G.B.

    1988-01-01

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.)

  14. X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.G.B.

    1988-01-06

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.).

  15. Identifying and closing gaps in environmental monitoring by means of metadata, ecological regionalization and geostatistics using the UNESCO biosphere reserve Rhoen (Germany) as an example.

    Science.gov (United States)

    Schröder, Winfried; Pesch, Roland; Schmidt, Gunther

    2006-03-01

    In Germany, environmental monitoring is intended to provide a holistic view of the environmental condition. To this end the monitoring operated by the federal states must use harmonized, resp., standardized methods. In addition, the monitoring sites should cover the ecoregions without any geographical gaps, the monitoring design should have no gaps in terms of ecologically relevant measurement parameters, and the sample data should be spatially without any gaps. This article outlines the extent to which the Rhoen Biosphere Reserve, occupying a part of the German federal states of Bavaria, Hesse and Thuringia, fulfills the listed requirements. The investigation considered collection, data banking and analysis of monitoring data and metadata, ecological regionalization and geostatistics. Metadata on the monitoring networks were collected by questionnaires and provided a complete inventory and description of the monitoring activities in the reserve and its surroundings. The analysis of these metadata reveals that most of the monitoring methods are harmonized across the boundaries of the three federal states the Rhoen is part of. The monitoring networks that measure precipitation, surface water levels, and groundwater quality are particularly overrepresented in the central ecoregions of the biosphere reserve. Soil monitoring sites are more equally distributed within the ecoregions of the Rhoen. The number of sites for the monitoring of air pollutants is not sufficient to draw spatially valid conclusions. To fill these spatial gaps, additional data on the annual average values of the concentrations of air pollutants from monitoring sites outside of the biosphere reserve had therefore been subject to geostatistical analysis and estimation. This yields valid information on the spatial patterns and temporal trends of air quality. The approach illustrated is applicable to similar cases, as, for example, the harmonization of international monitoring networks.

  16. Containment and Surveillance Equipment Compendium

    International Nuclear Information System (INIS)

    Luetters, F.O.

    1980-02-01

    The Containment and Surveillance Equipment Compendium contains information sections describing the application and status of seals, optical surveillance systems, and monitors for international safeguards systems. The Compendium is a collection of information on equipment in use (generally by the IAEA) or under development in the US in diverse programs being conducted at numerous facilities under different sponsors. The Compendium establishes a baseline for the status and applications of C/S equipment and is a tool to assist in the planning of future C/S hardware development activities. The Appendix contains design concepts which can be developed to meet future goals

  17. Instrumentation and equipment for monitoring and controlling NPP post-accident situations. Working material. Proceedings of a specialists' meeting held in Dimitrovgrad, Russian Federation, 12-15 September 1995

    International Nuclear Information System (INIS)

    1995-01-01

    The objectives of the Specialist's Meeting were: To provide an international forum for presentation and discussion on experience with instrumentation and equipment for monitoring and controlling NPP post-accident situations; to share experience on the design and improvements in the subject area; to identify and describe advanced features for safety and post-accident management improvements. In order to facilitate a structure discussion and not to omit important problem areas, papers on the following subjects were considered to be within the scope of the Specialist's Meeting: Analysis of existing post-accident instrumentation (in terms of range, qualification and redundancy) to support post-accident management. Requirements for post accident instrumentation and equipment - operating experience, regulations, standards; experience in upgrading of the existing instrumentation; instrumentation and equipment for emergency management systems (emergency rooms and national centers); post-accident computerized aids to assist operators; post-accident operating procedures; R and D in post-accident instrumentation, future trends. The present volume contains: (1) the papers presented by national delegates; (2) programme of the meeting; (3) description of the RIAR research facilities; and (4) list of participants. Refs, figs and tabs

  18. Pipe closing device

    International Nuclear Information System (INIS)

    Klahn, F.C.; Nolan, J.H.; Wills, C.

    1979-01-01

    The closing device closes the upper end of a support tube for monitoring samples. It meshes with the upper connecting piece of the monitorung sample capsule, and loads the capsule within the bore of the support tube, so that it is fixed but can be released. The closing device consists of an interlocking component with a chamber and several ratchets which hang down. The interlocking component surrounds the actuating component for positioning the ratchets. The interlocking and actuating components are movable axially relative to each other. (DG) [de

  19. Medical Issues: Equipment

    Science.gov (United States)

    ... Information Packets Equipment Pool Living With SMA Medical Issues Palliative Breathing Orthopedics Nutrition Equipment Daily Life At ... curesma.org > support & care > living with sma > medical issues > equipment Equipment Individuals with SMA often require a ...

  20. Semiconductor Manufacturing equipment introduction

    International Nuclear Information System (INIS)

    Im, Jong Sun

    2001-02-01

    This book deals with semiconductor manufacturing equipment. It is comprised of nine chapters, which are manufacturing process of semiconductor device, history of semiconductor manufacturing equipment, kinds and role of semiconductor manufacturing equipment, construction and method of semiconductor manufacturing equipment, introduction of various semiconductor manufacturing equipment, spots of semiconductor manufacturing, technical elements of semiconductor manufacturing equipment, road map of technology of semiconductor manufacturing equipment and semiconductor manufacturing equipment in the 21st century.

  1. Arduino Based Infant Monitoring System

    Science.gov (United States)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  2. Personal protective equipment

    International Nuclear Information System (INIS)

    2004-01-01

    This Practical Radiation Technical Manual is one of a series that has been designed to provide guidance on radiological protection for employers, radiation protection officers, managers and other technically competent persons who have responsibility for ensuring the safety of employees working with ionizing radiation. The Manual may be used with the appropriate IAEA Practical Radiation Safety Manuals to provide training, instruction and information for all employees engaged in work with ionizing radiation. Personal protective equipment (PPE) includes clothing or other special equipment that is issued to individual workers to provide protection against actual or potential exposure to ionizing radiations. It is used to protect each worker against the prevailing risk of external or internal exposure in circumstances in which it is not reasonably practicable to provide complete protection by means of engineering controls or administrative methods. Adequate personal protection depends on PPE being correctly selected, fitted and maintained. Appropriate training for the users and arrangements to monitor usage are also necessary to ensure that PPE provides the intended degree of protection effectively. This Manual explains the principal types of PPE, including protective clothing and respiratory protective equipment (RPE). Examples of working procedures are also described to indicate how PPE should be used within a safe system of work. The Manual will be of most benefit if it forms part of a more comprehensive training programme or is supplemented by the advice of a qualified expert in radiation protection. Some of the RPE described in this Manual should be used under the guidance of a qualified expert

  3. Technical and economical assesment of uranium mine closing down in Romania

    International Nuclear Information System (INIS)

    Cotrau, M.; Georgescu, P. D.

    2000-01-01

    The work presents the technical and economical aspects of two uranium mine closing down after 40 years of operation. Remedial actions, underground water decontamination, ecological programs and environmental effect monitoring are discussed. The technical and economical aspects related to the mine closing down are the following: recovering of recyclable equipment and materials; measures of controlling the mine void flooding; measures of controlling, directing and treatment of contaminated mine waters; site rehabilitation and land reclamation; treatment of surface waters; environment monitoring for as long as ten years. The funds for these projects are provided by government and a PHARE program. (authors)

  4. Selection of equipment for equipment qualification

    International Nuclear Information System (INIS)

    Torr, K.G.

    1989-01-01

    This report describes the methodology applied in selecting equipment in the special safety systems for equipment qualification in the CANDU 600 MW nuclear generating stations at Gentilly 2 and Point Lepreau. Included is an explanation of the selection procedure adopted and the rationale behind the criteria used in identifying the equipment. The equipment items on the list have been grouped into three priority categories as a planning aid to AECB staff for a review of the qualification status of the special safety systems

  5. Monitoring the residual life of atomic power station equipment based on the indices of stress-corrosion strength of constructional materials

    International Nuclear Information System (INIS)

    Stepanov, I.A.

    1994-01-01

    The properties of a constructional material determining life are strength, plasticity, and crack resistance. Loss of properties occurs as the result of corrosion, temperature action, actual and residual stresses, and neutron and gamma-radiation. Corrosion leads to a decrease in thickness, loss of density, changes in the composition and structure of the surface layers, and a reduction in strength, plasticity, and crack resistance of constructional materials. The influence of temperature on the loss of properties of materials is revealed as possible phase and structural transformations of the metal and the surface layers and a reduction in the stress-rupture, plastic, and thermal-fatigue properties. The actual and residual stresses not only strengthen the influence of corrosive media but also directly determine the stress-rupture strength and cyclic life. The influence of neutron and gamma-radiation is based o the change in composition of the corrosive medium (radiolysis), radiation embrittlement of the material, and the change in properties of the surface and oxide layers. The authors discuss the concepts and design of automated monitoring systems for determining the fitness of the components of on atomic power plant

  6. A Critical Review of Consumer Wearables, Mobile Applications, and Equipment for Providing Biofeedback, Monitoring Stress, and Sleep in Physically Active Populations

    Directory of Open Access Journals (Sweden)

    Jonathan M. Peake

    2018-06-01

    Full Text Available The commercial market for technologies to monitor and improve personal health and sports performance is ever expanding. A wide range of smart watches, bands, garments, and patches with embedded sensors, small portable devices and mobile applications now exist to record and provide users with feedback on many different physical performance variables. These variables include cardiorespiratory function, movement patterns, sweat analysis, tissue oxygenation, sleep, emotional state, and changes in cognitive function following concussion. In this review, we have summarized the features and evaluated the characteristics of a cross-section of technologies for health and sports performance according to what the technology is claimed to do, whether it has been validated and is reliable, and if it is suitable for general consumer use. Consumers who are choosing new technology should consider whether it (1 produces desirable (or non-desirable outcomes, (2 has been developed based on real-world need, and (3 has been tested and proven effective in applied studies in different settings. Among the technologies included in this review, more than half have not been validated through independent research. Only 5% of the technologies have been formally validated. Around 10% of technologies have been developed for and used in research. The value of such technologies for consumer use is debatable, however, because they may require extra time to set up and interpret the data they produce. Looking to the future, the rapidly expanding market of health and sports performance technology has much to offer consumers. To create a competitive advantage, companies producing health and performance technologies should consult with consumers to identify real-world need, and invest in research to prove the effectiveness of their products. To get the best value, consumers should carefully select such products, not only based on their personal needs, but also according to the

  7. Using ADA Tasks to Simulate Operating Equipment

    Science.gov (United States)

    DeAcetis, Louis A.; Schmidt, Oron; Krishen, Kumar

    1990-01-01

    A method of simulating equipment using ADA tasks is discussed. Individual units of equipment are coded as concurrently running tasks that monitor and respond to input signals. This technique has been used in a simulation of the space-to-ground Communications and Tracking subsystem of Space Station Freedom.

  8. A Perspective on Equipment Design for Fusion Remote Handling

    International Nuclear Information System (INIS)

    Mills, S.; Haist, B.; Hamilton, D.

    2006-01-01

    For 8 years, JET remote operations have become more capable and confident. Many tasks have been successfully completed, even those never intended to be remote maintenance activities. The general approach to the provision of remote handling equipment at JET has been the preferred use of commercially-off-the-shelf equipment. In the areas of electrical, electronic, software and control this approach has been generally achievable. However, in the area of mechanical equipment it has been more difficult. In particular the RH tooling has been almost entirely bespoke as its requirements are highly sensitive to the design of the JET component being handled and there are many design variations. Hence, JET has required the design and manufacture of over 700 types of bespoke RH equipment. This paper will discuss the experience of introducing and developing remote handling mechanical equipment for JET. The paper will cover the relationship between the remote handling equipment and the JET component design and the potential for improving the design function. A major lesson from the introduction of remote handling to JET has been demonstration of the very close interdependency of the design of JET components with design of remote handling tooling. The JET remote handling manual was originally introduced as the vehicle to ensure remote handling compatibility by the introduction of standards. Experience has shown that in general the remote handling manual approach has been insufficient. Future fusion machines will be much more complex than JET and will demand even greater remote handling compatibility. This paper will discuss possible methods for improving this process. Equipment operating in a high radiation environment must be dependable It may spend part of its time in areas that would be extremely difficult to recover from in the case of failure. The equipment may also have a high duty cycle to minimise shutdown times and probably cannot be manually inspected on a frequent

  9. Scientific Equipment Division - Overview

    International Nuclear Information System (INIS)

    Halik, J.

    2001-01-01

    . The machine allows the following tool movements in particular axes: X - 1000 mm, Y- 500 mm, Z - 500 mm; it is controlled by HEIDENHAIN 407 Control System, and ensures the accuracy and reproducibility of machining of 0.01 mm in each of the axis. In 2000, the Department of Mechanical Construction designed, manufactured and assembled an equipment for the following foreign laboratories: - Deutches Elektronen Synchrotron, Hamburg, FRG; - Forschungszentrum Karlsruhe, FRG; - Institute of Physics, Polish Academy of Sciences, Warsaw, Poland; - Jagiellonian University, Cracow, Poland; - Massachusetts Institute of Technology, Cambridge, Massachusetts, USA; - Brookhaven National Laboratory, Upton, NY, USA. Besides the large designs and systems described below, some interesting works were made for the departments of our Institute and other institutions: 1. Design and manufacturing of the new photon calorimeter of Luminosity Monitor for ZEUS Experiment at DESY; 2. Final installation of Detector Enclosures and Dry Air System for PHOBOS Experiment at BNL; 3. Design and manufacturing of the shutter and manufacturing of supporting structures for AUGER Project in Argentina; 4. Manufacturing and installation of Deflectors I and II for cyclotron AIC-144 at our Institute; 5. Design and manufacturing of resonator joggle for cyclotron AIC-144 at our Institute; 6. Upgrade of outlet chamber of for cyclotron AIC-144 at our Institute. (author)

  10. Detection of Equipment Faults Before Beam Loss

    CERN Document Server

    Galambos, J.

    2016-01-01

    High-power hadron accelerators have strict limits on fractional beam loss. In principle, once a high-quality beam is set up in an acceptable state, beam loss should remain steady. However, in practice, there are many trips in operational machines, owing to excessive beam loss. This paper deals with monitoring equipment health to identify precursor signals that indicate an issue with equipment that will lead to unacceptable beam loss. To this end, a variety of equipment and beam signal measurements are described. In particular, several operational examples from the Spallation Neutron Source (SNS) of deteriorating equipment functionality leading to beam loss are reported.

  11. Reviews Book: Nucleus Book: The Wonderful World of Relativity Book: Head Shot Book: Cosmos Close-Up Places to Visit: Physics DemoLab Book: Quarks, Leptons and the Big Bang EBook: Shooting Stars Equipment: Victor 70C USB Digital Multimeter Web Watch

    Science.gov (United States)

    2012-09-01

    WE RECOMMEND Nucleus: A Trip into the Heart of Matter A coffee-table book for everyone to dip into and learn from The Wonderful World of Relativity A charming, stand-out introduction to relativity The Physics DemoLab, National University of Singapore A treasure trove of physics for hands-on science experiences Quarks, Leptons and the Big Bang Perfect to polish up on particle physics for older students Victor 70C USB Digital Multimeter Equipment impresses for usability and value WORTH A LOOK Cosmos Close-Up Weighty tour of the galaxy that would make a good display Shooting Stars Encourage students to try astrophotography with this ebook HANDLE WITH CARE Head Shot: The Science Behind the JKF Assassination Exploration of the science behind the crime fails to impress WEB WATCH App-lied science for education: a selection of free Android apps are reviewed and iPhone app options are listed

  12. MONITORING AND SAFETY OF HANDLING EQUIPMENT

    Directory of Open Access Journals (Sweden)

    Janusz JURASZEK

    2014-04-01

    Full Text Available The paper presents a new solution for continuous measurement of deformations of the beam of travelling crane based on optical fibre Bragg gratings system. A verification of obtained results was done using resistive strain gauge method and magnetic metal memory method was used. Usage of the results of continuous measurements of deformation of the structure of the crane as actual boundary conditions in FEM numerical simulations was proposed in order to enable the analysis of the behaviour of whole structure.

  13. Monitoring of airborne contamination using mobile equipment

    Energy Technology Data Exchange (ETDEWEB)

    Honkamaa, T; Toivonen, H; Nikkinen, M

    1996-02-01

    Rapid and accurate measurements must be carried out in a nuclear disaster that releases radioactive material into the atmosphere. To evaluate the risk to the people, external dose rate and nuclide-specific activity concentrations in air must be determined. The Finnish Centre for Radiation and Nuclear Safety (STUK) has built an emergency vehicle to accomplish these tasks in the field. The systems and methods to determine the activity concentration in air is described in the report. (23 refs., 21 figs., 9 tabs.).

  14. Monitoring of airborne contamination using mobile equipment

    International Nuclear Information System (INIS)

    Honkamaa, T.; Toivonen, H.; Nikkinen, M.

    1996-02-01

    Rapid and accurate measurements must be carried out in a nuclear disaster that releases radioactive material into the atmosphere. To evaluate the risk to the people, external dose rate and nuclide-specific activity concentrations in air must be determined. The Finnish Centre for Radiation and Nuclear Safety (STUK) has built an emergency vehicle to accomplish these tasks in the field. The systems and methods to determine the activity concentration in air is described in the report. (23 refs., 21 figs., 9 tabs.)

  15. Closing remarks

    International Nuclear Information System (INIS)

    Reig, J.

    2007-01-01

    Good afternoon. Before providing the closing remarks on behalf of the NEA, I would like to take this opportunity and make some personal reflections, if you allow me Mr. Chairman. I have had the opportunity to take part in the three workshops on public communication organised by the NEA. In the first one in Paris in 2000, representing my country, Spain, and in the two last ones in Ottawa in 2004 and Tokyo today, on behalf of the NEA. The topics for the three workshops follow a logical order, first the focus was on investing in trust in a time when public communication was becoming a big challenge for the regulators. Second, maintaining and measuring public confidence to assess how credible regulators are in front of the public; and finally here in Tokyo, transparency, which is a basic element to achieve trust and credibility. In my view, a regulatory decision has three main components, it has to be technically sound. legally correct and well communicated. The emphasis in the early years was in the technical matters, till legal issues became a key element to achieve the political acceptance from governments and local authorities. Finally the public communication aspects resulted into a major effort and challenge to achieve social acceptance. (author)

  16. Closing Statement

    International Nuclear Information System (INIS)

    Varjoranta, T.

    2015-01-01

    For me, this week has been a success. I have been impressed with the range and depth of discussion that has taken place, not only in the formal sessions, but also in the coffee breaks, over lunch and into the evening. When we placed an international call for papers earlier this year, we did not expect that we would receive 400 abstracts and end up arranging 237 oral presentations and 91 poster sessions. There have been over 600 participants originating from 54 Member States and 11 invited organizations. A wealth of information and analysis arising from this week's deliberations is now available on the Agency website. This provides you with the chance to catch up on any presentations that you may have missed the first time, as well as providing a resource for future research and application. If you recall, the purpose of the symposium was to foster dialogue and exchange of information involving Member States, the nuclear industry and members of the broader nuclear non-proliferation community, including civil society. I believe we have succeeded on that score. We are living in a rapidly changing world and the nuclear world is no exception. More nuclear material and facilities are coming under safeguards all the time. International nuclear cooperation between States is intensifying with an expansion of trade and services in nuclear and related equipment, items and materials. Also, technologies are changing. Many older nuclear plants are being modernized and becoming more technologically sophisticated. The geographical focus of these expanding programmes also continues to change. Yet, our budget remains static. This means that the only way we can maintain our effectiveness in the face of rising demand for our services, is to become more productive. That is the backdrop to this symposium. The overarching theme was to link strategy, implementation and people: the three core processes of any business. As I said on Monday, the strength of the link between these three

  17. Influência da distância entre passadas de colhedora equipada com monitor de colheita na precisão dos mapas de produtividade na cultura do milho Influence of distance between combines equipped with yield monitors on the precision of yield maps for corn crops

    Directory of Open Access Journals (Sweden)

    Cláudio L. Bazzi

    2008-06-01

    Full Text Available Um dos entraves para a maior expansão da agricultura de precisão está, principalmente, no elevado custo dos equipamentos a serem utilizados. A geração de mapas de produtividade é a fase de mais fácil execução na agricultura de precisão. Entretanto, quando várias colhedoras operam simultaneamente em uma determinada área, nem sempre é possível dispor de monitores de colheita em todas as máquinas. Assim, neste trabalho, foi avaliado o decréscimo da precisão em mapas de produtividade obtidos a partir de áreas onde se utilizaram colhedoras não-equipadas com monitor de colheita associadas a colhedoras monitoradas. Também foram comparados os métodos de interpolação "inverso da distância ao quadrado" e "krigagem". Inicialmente, a interpolação do mapa com todos os pontos de amostragem (original foi gerada e, a partir dessa, foi feita a eliminação de passadas de modo a obter os mapas simulados. Na comparação entre os mapas simulados e o original, foi utilizado o coeficiente de desvio relativo - CDR, e o índice kappa. O número de passadas eliminadas diminuiu a precisão dos mapas em ambos os métodos de interpolação. Sendo assim, a quantidade mínima necessária de monitores em um conjunto de colhedoras depende da precisão desejada. Portanto, as máquinas devem ser intercaladas de maneira que as amostras sejam coletadas uniformemente por toda a área a ser colhida.One of the main obstacles to the larger expansion of precision agriculture is the high cost of the equipments to be used. The generation of yield maps is the easiest step in the sequence of the precision agriculture process. Nevertheless, the availability of yield monitors for all the machines is not always possible when several combines are concomitantly harvesting in a given area. Within this context, this research was carried out aiming to evaluate the decrease of precision of yield maps obtained from data collected in areas where combines not equipped with

  18. Prevention measures for avoiding unexpected drifting of marine component in recovery equipment of significant metals from sea water. Positioning and monitoring system for marine component and improvement of its positioning accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Tamada, Masao; Kasai, Noboru; Seko, Noriaki; Hasegawa, Shin; Takeda, Hayato; Katakai, Akio; Sugo, Takanobu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Kawabata, Yukiya [Ebara Reseach Co., Ltd., Fujisawa, Kanagawa (Japan); Onuma, Kenji [Mitsubishi Materials Corp., Tokyo (Japan)

    2001-11-01

    Positioning and monitoring system for marine component in recovery equipment of significant metals from seawater with adsorbent was designed and assembled to avoid unexpected drifting accident. This system which was set on float part of the marine component obtains the positioning data from GPS satellites and sends them to Takasaki and Mutsu establishments through satellite communication. In both establishments, the position data were shown in computer displays. As characteristic test for 20 days in the real sea, 262 data were obtained every 2 hours. The twice of the distance root mean square (2DRMS) was 223.7 m. To improve this performance, three new functions were added to the present firmware. There are to raise positioning resolutions in longitude and latitude from 0.001 to 0.00001 degree, to remove the reflection of GPS signal from sea surface, and to average remaining three positioning data after maximum and minimum data were omitted from continuous five positioning data. The improved system shows the 2DRMS positioning of 15.5 m. This performance is enough to prevent marine component from its drifting accident. (author)

  19. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment developed for the renewal of the network of stations automatic monitoring environmental radiation of the Generalitat of Catalunya; Calibracion y estudio de las capacidades de medida de los equipos de espectrometria gamma en tiempo real desarrollados para la renovacion de la Red de Estaciones Automaticas de vigilancia radiologia ambiental de la Generalitat de Catalunya

    Energy Technology Data Exchange (ETDEWEB)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2014-10-01

    The renewal of the automatic environmental radiation surveillance network of the Generalitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. the monitors use scintillation crystals, either Na(TI) or LaBr{sub 3}(Ce) and currently, there are 3 types of equipment water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentration for some isotopes. (Author)

  20. Shipboard and laboratory equipment

    Digital Repository Service at National Institute of Oceanography (India)

    Shyamprasad, M.; Ramaswamy, V.

    The polymetallic nodules occur at an average depth of 4500 m. Adequate equipment and techniques are required for the exploration at such depths. Shipboard and various laboratory equipments for the sampling of polymetallic nodules is described...

  1. Remote handling equipment

    International Nuclear Information System (INIS)

    Clement, G.

    1984-01-01

    After a definition of intervention, problems encountered for working in an adverse environment are briefly analyzed for development of various remote handling equipments. Some examples of existing equipments are given [fr

  2. Exercise Equipment: Neutral Buoyancy

    Science.gov (United States)

    Shackelford, Linda; Valle, Paul

    2016-01-01

    Load Bearing Equipment for Neutral Buoyancy (LBE-NB) is an exercise frame that holds two exercising subjects in position as they apply counter forces to each other for lower extremity and spine loading resistance exercises. Resistance exercise prevents bone loss on ISS, but the ISS equipment is too massive for use in exploration craft. Integrating the human into the load directing, load generating, and motion control functions of the exercise equipment generates safe exercise loads with less equipment mass and volume.

  3. BP volume reduction equipment

    International Nuclear Information System (INIS)

    Kitamura, Yoshinori; Muroo, Yoji; Hamanaka, Isao

    2003-01-01

    A new type of burnable poison (BP) volume reduction system is currently being developed. Many BP rods, a subcomponent of spent fuel assemblies are discharged from nuclear power reactors. This new system reduces the overall volume of BP rods. The main system consists of BP rod cutting equipment, equipment for the recovery of BP cut pieces, and special transport equipment for the cut rods. The equipment is all operated by hydraulic press cylinders in water to reduce operator exposure to radioactivity. (author)

  4. Design considerations, tooling and equipment for remote in-service inspection of radioactive piping and pressure vessel systems

    International Nuclear Information System (INIS)

    Schmoker, D.S.; Swannack, D.L.

    1983-01-01

    In-Service Inspection programs are performed to monitor and verify the integrity of a nuclear power plant's primary pressure boundaries. Early detection of abnormal structural or material degradation could preclude serious damage to plant systems. This paper summarizes results obtained in use of remotely-operated nondestructive testing (NDT) equipment for inspection of reactor system components. Experience obtained in operating the Fast Flux Test Facility (FFTF) has provided a basis for field verification of remote NDT equipment designs and has suggested development improvements. Remote Viewing and data gathering systems used include periscopes, borescopes, fiberscopes, hybrid borescopes/fiberscopes, and closed circuit television. A summary of design consideration for inspection equipment and power plant design is presented to achieve improved equipment operation and reduction of plant maintenance downtime

  5. Development of remote operated floor contamination monitor

    International Nuclear Information System (INIS)

    Sreekumar, K.; Gangamohan, M.; Kannan, R.K.; Rajan, S.

    2005-01-01

    Contamination check of floors and walkways in and around Reactor building areas forms an integral part of Radiation Protection Program in Power Stations. Though random swipe check method is adopted for the detection of loose contamination, this method has the disadvantage of leaving the fixed contamination and hotspots undetected. Hence, scanning the area with a sensitive detector, held close to the surface provides positive means for the detection of contamination. Checking large areas and walkways by holding the detector close to the surface involves physical work. Also, areas which are unapproachable due to congestion of equipment, may go uncovered by contamination monitoring in order to eliminate the physical strain involved in such contamination monitoring and to cover unapproachable areas, a small size prototype device that can be operated remotely was fabricated. This device detects contamination instantaneously and accurately. This paper describes design and fabrication of the device used for floor contamination monitoring. (author)

  6. Digital radiation monitor system

    International Nuclear Information System (INIS)

    Quan Jinhu; Zhai Yongchun; Guan Junfeng; Ren Dangpei; Ma Zhiyuan

    2003-01-01

    The article introduced digital radiation monitor system. The contents include: how to use advanced computer net technology to establish equipment net for nuclear facility, how to control and manage measuring instruments on field equipment net by local area net, how to manage and issue radiation monitoring data by internet

  7. Closing the gasoline system

    International Nuclear Information System (INIS)

    Hutcheson, R.C.

    1992-01-01

    In this paper, a representative of the Oil Companies' European Organization for Environmental and Health Protection (CONCAWE), argues the advantages of closing the gasoline system. Because this decouples the product from the environment, health risks and environmental damage are reduced. It is also more effective than changing the composition of gasoline because it offers better cost effectiveness, energy efficiency and the minimization of carbon dioxide release into the environment. However it will take time and political will to change until all European vehicles are fitted with three way catalysts and carbon canisters: control systems to monitor such systems will also need to be set up. However CONCAWE still recommends its adoption. (UK)

  8. Electrical equipment qualification

    International Nuclear Information System (INIS)

    Farmer, W.S.

    1983-01-01

    Electrical equipment qualification research programs being carried out by CEA, JAERI, and Sandia Laboratories are discussed. Objectives of the program are: (1) assessment of accident simulation methods for electrical equipment qualification testing; lower coarse (2) evaluation of equipment aging and accelerated aging methods; (3) determine radiation dose spectrum to electrical equipment and assess simulation methods for qualification; (4) identify inadequacies in electrical equipment qualification procedures and standards and potential failure modes; and (5) provide data for verifying and improving standards, rules and regulatory guides

  9. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  10. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  11. Maintenance and fabrication of nuclear electronic equipment

    International Nuclear Information System (INIS)

    Hong, Seok Boong; Chung, Chong Eun; Hwang, In Koo; Koo, In Soo; Park, Bum; Kim, Soo Hee; Lee, Seong Joo; Kim, Min Seok; Choi, Wha Lim

    2011-12-01

    - process equipment at PIEF, Chemical Analysis Team and RWFTF have been calibrated. - The electronic equipment and radiation equipment at RWTF and PIEF have been prepared. - Development and installation of integrated RMS software for Hanaro Cold Neutron Laboratory Building(CNLB) RMS, and development and performance upgrade of a portal monitor for CNLB. - Performance test of the Hardware/Software of digital unit controller has been performed, and functional upgrade of the Hardware/Software of stimulator for SMART MMIS performance test facility has also been performed. - A controller of high voltage power supply for a small electron beam generator and a controller for razer pinning and a remote monitoring apparatus of cathode power supply for a 0.2 Mev. small electron beam generator have been designed and fabricated. - Database construction for effective maintenance for the process equipment and radiation instruments are designed and constructed

  12. Equipment Reliability Process in Krsko NPP

    International Nuclear Information System (INIS)

    Gluhak, M.

    2016-01-01

    To ensure long-term safe and reliable plant operation, equipment operability and availability must also be ensured by setting a group of processes to be established within the nuclear power plant. Equipment reliability process represents the integration and coordination of important equipment reliability activities into one process, which enables equipment performance and condition monitoring, preventive maintenance activities development, implementation and optimization, continuous improvement of the processes and long term planning. The initiative for introducing systematic approach for equipment reliability assuring came from US nuclear industry guided by INPO (Institute of Nuclear Power Operations) and by participation of several US nuclear utilities. As a result of the initiative, first edition of INPO document AP-913, 'Equipment Reliability Process Description' was issued and it became a basic document for implementation of equipment reliability process for the whole nuclear industry. The scope of equipment reliability process in Krsko NPP consists of following programs: equipment criticality classification, preventive maintenance program, corrective action program, system health reports and long-term investment plan. By implementation, supervision and continuous improvement of those programs, guided by more than thirty years of operating experience, Krsko NPP will continue to be on a track of safe and reliable operation until the end of prolonged life time. (author).

  13. Long-term monitoring on a closed-conduit volcano: A 25 year long time-series of temperatures recorded at La Fossa cone (Vulcano Island, Italy), ranging from 250 °C to 520 °C

    Science.gov (United States)

    Diliberto, Iole Serena

    2017-10-01

    The longest record of temperature data from an active volcano in southern Italy is presented. The dataset comes from continuous monitoring of fumarole temperatures from the La Fossa cone of Vulcano (Aeolian Islands) running from 1991 to 2016. The discussion includes an empirical approach, based on a large number of direct measurements. At Vulcano Island, geochemical monitoring of the uprising fluids allows detection of the surface effects of perturbation in the state variables of the buried hydrothermal and magmatic systems. The presented datasets show that fumaroles' changing temperatures, which are related to surface heat flow, are useful indicators. Over the past 25 years, the combined effects of runoff and chemo-physical alterations were negligible on the output temperature of the earliest monitored fumaroles. The maximum recorded variation was 298 °C (measured in the ground very close to the steaming vents, at a depth of 0.5 m). Repetition of output temperature values occurred after 19 years in the same position; the time variations suggest a cyclic characteristic, although more years are needed to register the complete cyclic modulation. A combination of minor cyclical variations has also been registered in the fumarole output. The minor cycles appeared in this long series of data after 1995, and they can be interpreted as one of the surface effects of temporary departures from a stationary state assumed for the system feeding the La Fossa area. In this sector of the Mediterranean area, the steady state pressure field, as well as the steady state temperature gradients, can be perturbed either by magmatism or by seismo-tectonic processes related to regional dynamics. This long-term monitoring allowed comparisons of many temperature subsets with other validated geochemical and geophysical data series and highlighted common source mechanisms accounting for endogenous processes. Changes in the magma source and/or seismo-tectonic activity have been the primary

  14. Requirements for industrial x-ray equipment

    International Nuclear Information System (INIS)

    1987-01-01

    This safety code is concerned with the protection of all individuals who may be exposed to radiation emitted by X-ray equipment operating at energies up to 1 MeV as used in industrial radiography. This code presents basic radiation safety information for the protection of personnel operating and servicing X-ray equipment and other workers and the general public in the vicinity of areas where X-ray equipment is in operation. It specifies general safety features of design, construction and functioning of X-ray equipment and facilities; describes the responsibilities of the user, operator and maintenance personnel; contains recommendations to ensure that the X-ray equipment is used and maintained in accordance with the ALARA principle; and describes a program of personnel monitoring and radiation safety surveys. ( 6 refs., 5 tabs., 4 figs.)

  15. RETRIEVAL EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    J. Steinhoff

    1997-01-01

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) retrieval from the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. There are no quality assurance requirements or QA controls in this document. Retrieval under normal conditions is accomplished with the same fleet of equipment as is used for emplacement. Descriptions of equipment used for retrieval under normal conditions is found in Emplacement Equipment Descriptions, DI: BCAF00000-01717-5705-00002 (a document in progress). Equipment used for retrieval under abnormal conditions is addressed in this document and consists of the following: (1) Inclined Plane Hauler; (2) Bottom Lift Transporter; (3) Load Haul Dump (LHD) Loader; (4) Heavy Duty Forklift for Emplacement Drifts; (5) Covered Shuttle Car; (6) Multipurpose Vehicle; and (7) Scaler

  16. Medical equipment management

    CERN Document Server

    Willson, Keith; Tabakov, Slavik

    2013-01-01

    Know What to Expect When Managing Medical Equipment and Healthcare Technology in Your Organization As medical technology in clinical care becomes more complex, clinical professionals and support staff must know how to keep patients safe and equipment working in the clinical environment. Accessible to all healthcare professionals and managers, Medical Equipment Management presents an integrated approach to managing medical equipment in healthcare organizations. The book explains the underlying principles and requirements and raises awareness of what needs to be done and what questions to ask. I

  17. Data communication equipment

    International Nuclear Information System (INIS)

    Kim, Hak Seon; Lee, Sang Mok

    1998-02-01

    The contents of this book are introduction of data communication on definition, purpose and history, information terminal about data communication system and data transmission system, data transmit equipment of summary, transmission cable, data port, concentrator and front-end processor, audio communication equipment like phones, radio communication equipment of summary on foundation of electromagnetic waves, AM transmitter, AM receiver, FM receiver and FM transmitter, a satellite and mobile communication equipment such as earth station, TT and C and Cellular phone, video telephone and new media apparatus.

  18. Cooling of electronic equipment

    DEFF Research Database (Denmark)

    A. Kristensen, Anders Schmidt

    2003-01-01

    Cooling of electronic equipment is studied. The design size of electronic equipment decrease causing the thermal density to increase. This affect the cooling which can cause for example failures of critical components due to overheating or thermal induced stresses. Initially a pin fin heat sink...

  19. Capital Equipment Replacement Decisions

    OpenAIRE

    Batterham, Robert L.; Fraser, K.I.

    1995-01-01

    This paper reviews the literature on the optimal replacement of capital equipment, especially farm machinery. It also considers the influence of taxation and capital rationing on replacement decisions. It concludes that special taxation provisions such as accelerated depreciation and investment allowances are unlikely to greatly influence farmers' capital equipment replacement decisions in Australia.

  20. Equipment Reliability Program in NPP Krsko

    International Nuclear Information System (INIS)

    Skaler, F.; Djetelic, N.

    2006-01-01

    rule, system health, equipment performance monitoring, long-range planning, etc.) into a single efficient and effective process. (author)

  1. Experience with rotating equipment in FBTR

    International Nuclear Information System (INIS)

    Babu, A.; Subramanian, K.G.; Selvam, B.

    2006-01-01

    Fast breeder test reactor (FBTR) is a 40MWth sodium cooled PuC-UC fuelled fast breeder reactor located at Kalpakkam, Tamilnadu. FBTR has a variety of mechanical and electrical equipment comprising of single stage and multi stage water pumps, sodium pumps, compressors, Chiller units, Diesel Generator sets, vacuum pumps, ventilation fans, Turbo generator etc. The degree and extent of maintenance on these equipment are decided based on nuclear safety, station technical specification requirements, design criteria and operating philosophy. The variety and complexity of the equipment in FBTR demands various maintenance strategies (preventive, predictive, proactive etc.) for their upkeep. This paper discusses the performance of all mechanical and electrical equipment in FBTR, measures taken for their upkeep, major modifications done to prevent recurring failures, condition monitoring programme implemented, Maintenance Management and Information System developed for data acquisition and dissemination, etc. (author)

  2. Case Based Asset Maintenance for the Electric Equipment

    International Nuclear Information System (INIS)

    Kim, Ji-Hyeon; Jung, Jae-Cheon; Chang, Young-Woo; Chang, Hoon-Seon; Kim, Jae-Cheol; Kim, Hang-Bae; Kim, Kyu-Ho; Hur, Yong; Lee, Dong-Chul

    2006-01-01

    The electric equipment maintenance strategies are changing from PM(Preventive Maintenance) or CM(Corrective Maintenance) to CBM(Condition Based Maintenance). The main benefits of CBM are reduced possibility of service failures of critical equipment and reduced costs or maintenance work. In CBM, the equipment status need to be monitored continuously and a decision should be made whether an equipment need to be repaired or replaced. For the maintenance decision making, the CBR(Case Base Reasoning) system is introduced. The CBR system receives the current equipment status and retrieves the case based historic database to determine any possible equipment failure under current conditions. In retrieving the case based historic data, the suggested DSS(Decision Support System) uses a reasoning engine with an equipment/asset ontology that describes the equipment subsumption relationships

  3. HVAC systems and equipment

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.T. (Linford Air and Refrigeration Company, Oakland, CA (US))

    1990-02-01

    The author discusses the section of the ASHRAE Standard 90.1-1989 which addresses HVAC systems and equipment. New features of HVAC systems mandatory general requirements are described. New prescriptive requirements are detailed.

  4. Personal Protective Equipment

    National Research Council Canada - National Science Library

    1998-01-01

    ... of personal protective equipment A safety program for new employees is a necessary part of any orientation program An on-going safety program should be used to motivate employees to continue to use...

  5. Electronic equipment packaging technology

    CERN Document Server

    Ginsberg, Gerald L

    1992-01-01

    The last twenty years have seen major advances in the electronics industry. Perhaps the most significant aspect of these advances has been the significant role that electronic equipment plays in almost all product markets. Even though electronic equipment is used in a broad base of applications, many future applications have yet to be conceived. This versatility of electron­ ics has been brought about primarily by the significant advances that have been made in integrated circuit technology. The electronic product user is rarely aware of the integrated circuits within the equipment. However, the user is often very aware of the size, weight, mod­ ularity, maintainability, aesthetics, and human interface features of the product. In fact, these are aspects of the products that often are instrumental in deter­ mining its success or failure in the marketplace. Optimizing these and other product features is the primary role of Electronic Equipment Packaging Technology. As the electronics industry continues to pr...

  6. CV equipment responsibilities

    CERN Document Server

    Pirollet, B

    2008-01-01

    This document describes the limits of the responsibilities of the TS/CV for fire fighting equipment at the LHC. The various interfaces, providers and users of the water supply systems and clean water raising systems are described.

  7. Equipment for hydraulic testing

    International Nuclear Information System (INIS)

    Jacobsson, L.; Norlander, H.

    1981-07-01

    Hydraulic testing in boreholes is one major task of the hydrogeological program in the Stripa Project. A new testing equipment for this purpose was constructed. It consists of a downhole part and a surface part. The downhole part consists of two packers enclosing two test-sections when inflated; one between the packers and one between the bottom packer and the bottom of the borehole. A probe for downhole electronics is also included in the downhole equipment together with electrical cable and nylon tubing. In order to perform shut-in and pulse tests with high accuracy a surface controlled downhole valve was constructed. The surface equipment consists of the data acquisition system, transducer amplifier and surface gauges. In the report detailed descriptions of each component in the whole testing equipment are given. (Auth.)

  8. Progress on EPRI electrical equipment qualification research

    International Nuclear Information System (INIS)

    Sliter, G.E.

    1983-01-01

    The objective of EPRI's electrical equipment qualification research program is to provide technical assistance to utilities in meeting nuclear plant safety requirements in a manner consistent with the state of the art. This paper reports progress on several research projects including: radiation effects studies, which compile data on degradation of organic materials in electrical equipment exposed to operational and accident radiation doses; the Equipment Qualification Data Bank, which is a remotely accessible computer system for disseminating qualification information on in-plant equipment, seismic data, and materials data; an aging/seismic correlation program, which is providing test data showing that, in many cases, age degradation has a negligibly small effect on the performance of electrical components under seismic excitation; a review of condition monitoring techniques, which has identified surveillance methods for measuring key performance parameters that have the potential for predicting remaining equipment life; and large-scale hydrogen burn equipment response tests, which are providing data to assess the ability of equipment to remain functional during and after hydrogen burning in postulated degraded core accidents

  9. 40 CFR 61.135 - Standard: Equipment leaks.

    Science.gov (United States)

    2010-07-01

    ... stuffing box pressure; or (ii) Equipped with a barrier fluid system that is connected by a closed vent... system that purges the barrier fluid into a process stream with zero benzene emissions to the atmosphere...

  10. Area monitoring intelligent system - SIMA

    International Nuclear Information System (INIS)

    Bhoem, P.; Hisas, F.; Gelardi, G.

    1990-01-01

    The area monitoring intelligent system (SIMA) is an equipment to be used in radioprotection. SIMA has the function of monitoring the radiation levels of determined areas of the installations where radioactive materials are handled. (Author) [es

  11. 49 CFR 238.445 - Automated monitoring.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Automated monitoring. 238.445 Section 238.445... Equipment § 238.445 Automated monitoring. (a) Each passenger train shall be equipped to monitor the... limiting the speed of the train. (c) The monitoring system shall be designed with an automatic self-test...

  12. Improvement of the electromagnetic situation in networks of operational current at nuclear power plant for the purpose of ensuring reliability of monitoring systems, control, RPA and communications, realized on the basis of digital equipment

    International Nuclear Information System (INIS)

    Fomenko, O.V.; Moloshnaya, E.S.; Ul'yanova, Yu.E.

    2014-01-01

    The authors propose the technique of designing a portable grounding contour for protection and control systems, relay protection and automation (RPA) systems made on the basis of digital equipment in networks of an operational direct current to increase the reliability of their functioning under the conditions of influence of strong hindrances and improvement of an electromagnetic environment [ru

  13. 46 CFR 78.47-38 - Valves and closing appliances.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Valves and closing appliances. 78.47-38 Section 78.47-38... Fire and Emergency Equipment, Etc. § 78.47-38 Valves and closing appliances. (a) All valves and closing appliances, or other mechanisms which may be required to be operated for damage control purposes in case of...

  14. Prioritizing equipment for replacement.

    Science.gov (United States)

    Capuano, Mike

    2010-01-01

    It is suggested that clinical engineers take the lead in formulating evaluation processes to recommend equipment replacement. Their skill, knowledge, and experience, combined with access to equipment databases, make them a logical choice. Based on ideas from Fennigkoh's scheme, elements such as age, vendor support, accumulated maintenance cost, and function/risk were used.6 Other more subjective criteria such as cost benefits and efficacy of newer technology were not used. The element of downtime was also omitted due to the data element not being available. The resulting Periop Master Equipment List and its rationale was presented to the Perioperative Services Program Council. They deemed the criteria to be robust and provided overwhelming acceptance of the list. It was quickly put to use to estimate required capital funding, justify items already thought to need replacement, and identify high-priority ranked items for replacement. Incorporating prioritization criteria into an existing equipment database would be ideal. Some commercially available systems do have the basic elements of this. Maintaining replacement data can be labor-intensive regardless of the method used. There is usually little time to perform the tasks necessary for prioritizing equipment. However, where appropriate, a clinical engineering department might be able to conduct such an exercise as shown in the following case study.

  15. Process monitoring

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Many of the measurements and observations made in a nuclear processing facility to monitor processes and product quality can also be used to monitor the location and movements of nuclear materials. In this session information is presented on how to use process monitoring data to enhance nuclear material control and accounting (MC and A). It will be seen that SNM losses can generally be detected with greater sensitivity and timeliness and point of loss localized more closely than by conventional MC and A systems if process monitoring data are applied. The purpose of this session is to enable the participants to: (1) identify process unit operations that could improve control units for monitoring SNM losses; (2) choose key measurement points and formulate a loss indicator for each control unit; and (3) describe how the sensitivities and timeliness of loss detection could be determined for each loss indicator

  16. Radioactive decontamination of equipment

    International Nuclear Information System (INIS)

    1982-03-01

    After a recall of some definitions relating to decontamination techniques and of the regulation into effect, the principles to be respected to arrange rationally work zones are quoted while insisting more particularly on the types of coatings which facilitate maintenance operations and the dismantling of these installations. Then, the processes and equipments to use in decontamination units for routine or particular operations are described; the list of recommended chemical products to decontaminate the equipment is given. The influence of these treatments on the state and the duration of life of equipments is studied, and some perfectible methods are quoted. In the appendix, are given: the limits of surface contamination accepted in the centers; a standard project which defines the criteria of admissible residual contamination in wastes considered as cold wastes; some remarks on the interest that certain special ventilation and air curtain devices for the protection of operators working on apparatus generating contaminated dusts [fr

  17. Establishment for Nuclear Equipment: Overview

    International Nuclear Information System (INIS)

    Pracz, J.

    2001-01-01

    Full text: The activity of ZdAJ in 2000 was focused on realisation of the Government-Ordered Project - 6/15 MeV Accelerator. The realisation was accomplished in two stages: - stage I should result in deriving principal operational parameters of the accelerator - stage 2 will result in full implementation of the control system providing optimum control of the equipment and automatic maintaining of its parameters. Within the frames of the first stage, a klystron modulator panel was finished and the design documentation of the mechanical supporting structure, the arm, accelerating structure, collimator and control panel were advanced. Manufacturing of the above sub-units in the workshop has started. In the frames of the Specific Project of the State Committee for Scientific Research, the improvement of Neptun lOPC accelerator was undertaken. The read-out of the monitor dose with atmospheric pressure and ambient temperature compensation has been introduced. New filters for equalising the photon and electron beam and new wedge filters have been designed. Changes in programming have been introduced, which improve the patient's safety by eliminating possible personnel errors and increase the accuracy of radiation fields read-out. In 2000 ZdAJ progressed in development of the Quality System conforming EN-ISO 9001 Standard by including the provisions of EN 46001 Standard. The Standard EN 46001: ''Quality Systems - Medical Equipment''. Detailed requirements related to application of EN ISO 9001 is an European Quality Standard extending the provisions of EN ISO 9001 Standard over the manufacturers of medical equipment. (author)

  18. Equipment Operational Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

    2009-06-11

    The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

  19. Risk matrix model for rotating equipment

    Directory of Open Access Journals (Sweden)

    Wassan Rano Khan

    2014-07-01

    Full Text Available Different industries have various residual risk levels for their rotating equipment. Accordingly the occurrence rate of the failures and associated failure consequences categories are different. Thus, a generalized risk matrix model is developed in this study which can fit various available risk matrix standards. This generalized risk matrix will be helpful to develop new risk matrix, to fit the required risk assessment scenario for rotating equipment. Power generation system was taken as case study. It was observed that eight subsystems were under risk. Only vibration monitor system was under high risk category, while remaining seven subsystems were under serious and medium risk categories.

  20. Maintenence and fabrication of Electronic Equipment

    International Nuclear Information System (INIS)

    Chung, Chong Eun; Moon, Byung Soo; Hong, Suk Boong; Kim, Young Keun; Kim, Jung Bok; Lee, Sang Suk

    2004-12-01

    Development of the SPND Monitor could be the base of development of small signal processing circuits and the technique could be used to develop other precision equipment. The repair technology for high purity germanium(HPGe) detector system could be adapted to other areas where high purity detectors are used such as hospitals, universities etc. The technology of multi-channel ASIC for nuclear radiation detector, which has been imported from abroad, could be adapted to development of radiation equipment for image processing, position of detection, NDT etc., and also the technique will be expected to contribute to increase the use of radiation technology to industrial applications

  1. Charging equipment. Ladegeraet

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, E

    1981-09-17

    The invention refers to a charging equipment, particularly on board charging equipment for charging traction batteries of an electric vehicle from the AC mains supply, consisting of a DC converter, which contains a controlled power transistor, a switching off unloading circuit and a power transmitter, where the secondary winding is connected in series with a rectifier diode, and a smoothing capacitor is connected in parallel with this series circuit. A converter module is provided, which consists of two DC voltage converters, whose power transistors are controlled by a control circuit in opposition with a phase displacement of 180/sup 0/.

  2. Division of Scientific Equipment - Overview

    International Nuclear Information System (INIS)

    Halik, J.

    2002-01-01

    allows the following tool movements in particular axes: X - 1000 mm, Y - 500 mm, Z - 500 mm; it is controlled by HEIDENHAIN 407 Control System, and ensures the accuracy and reproducibility of machining of 0.01 mm in each of the axis. In 2001 the Department of Mechanical Construction designed, manufactured and assembled an equipment for the following foreign laboratories: * Deutches Elektronen Synchrotron, Hamburg, FRG, * European Organization for Nuclear Research CERN, Geneva, Switzerland, * Forschungszentrum Karlsruhe, FRG, * Institute of Physics, Polish Academy of Science, Warsaw, Poland, * Jagiellonian University, Cracow, Poland. Besides the large designs and systems described below, some interesting works were made for the departments of our Institute and other institutions: 1. Design and manufacturing of the new photon calorimeter of Luminosity Monitor for ZEUS Experiment at DESY, 2. Manufacturing of the shutter and supporting structures for AUGER Project in Argentina, 3. Manufacturing and assembly of 105 sets of mirror positioning devices for AUGER Project in Argentina, 4. Design of ion source for cyclotron AIC-144 at our Institute, 5. Design and manufacturing of a vacuum chamber and parts of vacuum lines for dual beam ion implantator at our Institute, 6. Design and manufacturing of experimental chamber for Proton Microprobe at our Institute. (author)

  3. Experimental equipment, ch. 6

    International Nuclear Information System (INIS)

    Boomstra, F.; Hoogenboom, A.M.; Prins, C.M.; Strasters, B.A.; Vermeer, A.; Wit, P. de; Zwol, N.A. van.

    1977-01-01

    The experimental equipment in use at Utrecht university is discussed. Attention is paid to the tandem Van de Graaff accelerator and the 4MV and 1MV accelerators. The detection systems for gamma-ray spectroscopy are reviewed with emphasis on the compton-suppression spectrometer. The data-handling system used for experiments with the tandem is also briefly discussed

  4. Equipment gift to Monaco

    International Nuclear Information System (INIS)

    1970-01-01

    Research work at the Agency's Laboratory of Marine Radioactivity in Monaco, including that concerned with pollution of the sea, has been made more effective by its latest acquisition of equipment. This is a spectrophotometer donated by the Federal Republic of Germany. (author)

  5. Lifetime of Mechanical Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Leland, K.

    1999-07-01

    The gas plant at Kaarstoe was built as part of the Statpipe gas transport system and went on stream in 1985. In 1993 another line was routed from the Sleipner field to carry condensate, and the plant was extended accordingly. Today heavy additional supply- and export lines are under construction, and the plant is extended more than ever. The main role of the factory is to separate the raw gas into commercial products and to pump or ship it to the markets. The site covers a large number of well-known mechanical equipment. This presentation deals with piping, mechanical and structural disciplines. The lifetime of mechanical equipment is often difficult to predict as it depends on many factors, and the subject is complex. Mechanical equipment has been kept in-house, which provides detailed knowledge of the stages from a new to a 14 years old plant. The production regularity has always been very high, as required. The standard of the equipment is well kept, support systems are efficient, and human improvisation is extremely valuable.

  6. Safeguards techniques and equipment

    International Nuclear Information System (INIS)

    1997-01-01

    The current booklet is intended to give a full and balanced description of the techniques and equipment used for both nuclear material accountancy and containment and surveillance measures, and for the new safeguards measure of environmental sampling. As new verification measures continue to be developed, the material in the booklet will be periodically reviewed and updated versions issued. (author)

  7. Equipping tomorrow's fire manager

    Science.gov (United States)

    Christopher A. Dicus

    2008-01-01

    Fire managers are challenged with an ever-increasing array of both responsibilities and critics. As in the past, fire managers must master the elements of fire behavior and ecology using the latest technologies. In addition, today’s managers must be equipped with the skills necessary to understand and liaise with a burgeoning group of vocal stakeholders while also...

  8. Electrical equipment design library

    International Nuclear Information System (INIS)

    1994-01-01

    This book guides the design supervision, construction order for electrical equipment. The contents of this library are let's use electricity like this, leading-in-pole and casual power, electric pole install below 300KVA, electric pole install below 301∼1000KVA, electric pole install exceed 1000KVA, rooftop install exceed 1000KVA, CUBICLE type, 154KV services. It adds an appendix.

  9. Orphee reactor experimental equipment

    International Nuclear Information System (INIS)

    1987-01-01

    Experimental equipment around the ORPHEE reactor is presented. The neutron source; and the spectrometers and sample environment (inelastic and quasi-elastic scattering, elastic scattering, spread scattering, small angle scattering) are described. An experiment proposal and reports guide is supplied [fr

  10. Seismic qualification of equipment

    International Nuclear Information System (INIS)

    Heidebrecht, A.C.; Tso, W.K.

    1983-03-01

    This report describes the results of an investigation into the seismic qualification of equipment located in CANDU nuclear power plants. It is particularly concerned with the evaluation of current seismic qualification requirements, the development of a suitable methodology for the seismic qualification of safety systems, and the evaluation of seismic qualification analysis and testing procedures

  11. Underground coal equipment

    Energy Technology Data Exchange (ETDEWEB)

    Chadwick, J.

    2002-12-01

    This paper reports on increasing automation and enhanced productivity on longwalls, new development cutting and bolting technologies and haulage systems. Amongst equipment discussed is DBT's Electra series EL3000 shearer, the Dosco LH1400 roadheader with onboard bolters, and Joy 12 CM30 continuous miners. 4 photos.

  12. Communication of 7 August 2007 from the Permanent Mission of Pakistan to the IAEA concerning the establishment of the oversight Board to monitor the implementation of Pakistan's export control on goods, technologies, materials and equipment related to nuclear and biological weapons and their Delivery Systems Act (Act No.V) 2004

    International Nuclear Information System (INIS)

    2007-01-01

    The Secretariat has received a Note Verbale dated 7 August 2007 from the Permanent Mission of Pakistan enclosing a copy of the Gazette of Pakistan S.R.O. No.693(I)/2007, dated 11 July 2007, regarding the establishment of the Oversight Board to monitor the implementation of Pakistan's Export Control on Goods, Technologies, Materials and Equipment related to Nuclear and Biological Weapons and their Delivery Systems Act (Act No.V) 2004, including the formation and functioning of Strategic Export Control Division. As requested in the Note Verbale, the Note Verbale and the enclosure thereto are circulated for the information of Member States

  13. The application and practice of predictive maintenance at CANDU equipment management

    International Nuclear Information System (INIS)

    Yu Guangting

    2014-01-01

    The equipment in Qinshan CANDU unit is characterized by large number and complex structure. Some equipment failure has no relation with the operation time, it is impossible to avoid the failure of these equipment only by periodical maintenance. To improve the equipment reliability, increase the equipment usability and decrease the maintenance cost, for important equipment related to nuclear safety and generating electricity, it is required to perform condition monitoring and the predictive maintenance (PdM). According to different characteristics of equipment, it is required to use suitable equipment condition monitoring method, content and frequency. In this way, some potential equipment failure can be found, preventive maintenance can be arranged in advance, and equipment maintenance management can be optimized. (author)

  14. Testing of FFTF fuel handling equipment

    International Nuclear Information System (INIS)

    Coleman, D.W.; Grazzini, E.D.; Hill, L.F.

    1977-07-01

    The Fast Flux Test Facility has several manual/computer controlled fuel handling machines which are exposed to severe environments during plant operation but still must operate reliably when called upon for reactor refueling. The test programs for two such machines--the Closed Loop Ex-Vessel Machine and the In-Vessel Handling Machine--are described. The discussion centers on those areas where design corrections or equipment repairs substantiated the benefits of a test program prior to plant operation

  15. Maintenance and fabrication of electronic equipment

    International Nuclear Information System (INIS)

    Chung, Chong Eun; Moon, Byung Soo; Hong, Suk Boong; Kim, Yong Keun; Kim, Jung Bok

    2003-12-01

    Development of radiation monitoring equipment could be the base of domestic development of RMS. And the technique could be adapted to development of other radiation equipment of KAERI as well as hospitals and nuclear power plants. The RMS technology could be adapted to the development of precision instruments related to nuclear radiation and be the base of fundamental technology such as protein structure analysis of bio technology, development of nano advanced material and aircraft material. The technology of multi-channel readout ASIC for nuclear radiation detector, which has been imported from abroad, could be adapted to development of radiation equipment for image processing, position of detection, NDT etc., and also the technique will be expected to contribute to increase the use of radiation technology to industrial applications

  16. Visual communication and terminal equipment

    International Nuclear Information System (INIS)

    Kang, Cheol Hui

    1988-06-01

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  17. Visual communication and terminal equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Cheol Hui

    1988-06-15

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  18. Equipment cost optimization

    International Nuclear Information System (INIS)

    Ribeiro, E.M.; Farias, M.A.; Dreyer, S.R.B.

    1995-01-01

    Considering the importance of the cost of material and equipment in the overall cost profile of an oil company, which in the case of Petrobras, represents approximately 23% of the total operational cost or 10% of the sales, an organization for the optimization of such costs has been established within Petrobras. Programs are developed aiming at: optimization of life-cycle cost of material and equipment; optimization of industrial processes costs through material development. This paper describes the methodology used in the management of the development programs and presents some examples of concluded and ongoing programs, which are conducted in permanent cooperation with suppliers, technical laboratories and research institutions and have been showing relevant results

  19. Tube for irradiation equipment

    International Nuclear Information System (INIS)

    Goehrich, K.; Vogt, H.

    1979-01-01

    This patent describes a tube for irradiation equipment for limiting an emergent beam, with a baseplate, possessing a central aperture, intended for attaching to the equipment, as well as four carrier plates, each of which possesses a limiting edge and a sliding edge located at right angles thereto. The carrier plates are located parallel to the baseplate, the limiting edge of each carrier plate resting against the sliding edge of the adjacent carrier plate and each of the two mutually opposite pairs of carrier plates being displaceable, parallel to the direction of its sliding edges and symmetrically to the center of the transmission aperture, for the purpose of continuously varying the transmission aperture defined by the limiting edges, during which displacement each of the displaced carrier plates carries with it the carrier plate, resting against the limiting edge of the former plate, parallel to the direction of the limiting edge of the latter plate. 8 claims

  20. Equipment for isotope diagnostics

    International Nuclear Information System (INIS)

    Platz, W.

    1976-01-01

    The invention concerns an improvement of equipment for isotope diagnostics allowing to mark special intensity ranges of the recorded measurements by means of different colors. For undisturbed operation it is of advantage to avoid electric circuits between movable and unmovable parts of the color recorder. According to the invention, long gear wheels of glass fiber-reinforced polyamide are used for these connections. (ORU) [de

  1. Soviet equipment flies in

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    End of February 1977 a Soviet Ilyushin-76 heavy freight aircraft landed at Cointrin airport having on board fifty large wire proprtional chambers and associated apparatus, together weighing 10 tons, supplied by the Joint Institute for Nuclear Research, Dubna, USSR. The equipment was for the CERN- Dubna-Munich-Saclay experiment NA4 on deep inelastic muon scattering being set up in the North Area of SPS. See Weekly Bulletin 11/78.

  2. Labelling of equipment dispensers.

    Science.gov (United States)

    Gray, D C

    1993-01-01

    A new labelling system for use on medical equipment dispensers is tested. This system uses one of the objects stored in each unit of the dispenser as the 'label', by attaching it to the front of the dispenser with tape. The new system was compared to conventional written labelling by timing subjects asked to select items from two dispensers. The new system was 27% quicker than the conventional system. Images Fig. 1 PMID:8110335

  3. Equipment Obsolescence Management Program

    Energy Technology Data Exchange (ETDEWEB)

    Redmond, J.

    2014-07-01

    Nuclear Power Plant (NPP) Operators are challenged with securing reliable supply channels for safety related equipment due to equipment obsolescence. Many Original Equipment Manufacturers (OEMs) have terminated production of spare parts and product life-cycle support. The average component life cycles are much shorter than the NPP design life, which means that replacement components and parts for the original NPP systems are not available for the complete design life of the NPPs. The lack or scarcity of replacement parts adversely affects plant reliability and ultimately the profitability of the affected NPPs. This problem is further compounded when NPPs pursue license renewal and approval for plant-life extension. A reliable and predictable supply of replacement co components is necessary for NPPs to remain economically competitive and meet regulatory requirements and guidelines. Electrical and I and C components, in particular, have short product life cycles and obsolescence issues must be managed pro actively and not reactively in order to mitigate the risk to the NPP to ensure reliable and economic NPP operation. (Author)

  4. Application of a portable equipment EDXRF (energy dispersive X-ray fluorescence) in the monitoring of the restoration work of murals paints in the Church of Paroquia Imaculada Conceicao (Sao Paulo, SP)

    International Nuclear Information System (INIS)

    Appoloni, Carlos Roberto; Parreira, Paulo Sergio; Rizzo, Marcia

    2006-01-01

    This paper presents the application of the portable EDXRF (energy dispersive X-ray fluorescence) of the Laboratorio de Fisica Nuclear Aplicada of the Universidade Estadual de Londrina in the analysis in situ of pigments in wall paintings, as well as in monitoring restoration processes

  5. Site 300 Bat Monitoring Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Drennan, Joe [Garcia and Associates, San Francisco, CA (United States); Tortosa, Justin [Garcia and Associates, San Francisco, CA (United States)

    2016-07-18

    From June 15 to 18, 2015, GANDA biologist Graham Neale assisted in programming and fieldtesting of the bat monitoring equipment. The equipment was deployed in the field on a meteorological (MET) tower within Site 300 on June 18, 2015.

  6. Methodology for assessing laser-based equipment

    Science.gov (United States)

    Pelegrina-Bonilla, Gabriel; Hermsdorf, Jörg; Thombansen, Ulrich; Abels, Peter; Kaierle, Stefan; Neumann, Jörg

    2017-10-01

    Methodologies for the assessment of technology's maturity are widely used in industry and research. Probably the best known are technology readiness levels (TRLs), initially pioneered by the National Aeronautics and Space Administration (NASA). At the beginning, only descriptively defined TRLs existed, but over time, automated assessment techniques in the form of questionnaires emerged in order to determine TRLs. Originally TRLs targeted equipment for space applications, but the demands on industrial relevant equipment are partly different in terms of, for example, overall costs, product quantities, or the presence of competitors. Therefore, we present a commonly valid assessment methodology with the aim of assessing laser-based equipment for industrial use, in general. The assessment is carried out with the help of a questionnaire, which allows for a user-friendly and easy accessible way to monitor the progress from the lab-proven state to the application-ready product throughout the complete development period. The assessment result is presented in a multidimensional metric in order to reveal the current specific strengths and weaknesses of the equipment development process, which can be used to direct the remaining development process of the equipment in the right direction.

  7. School Closings in Philadelphia

    Science.gov (United States)

    Jack, James; Sludden, John

    2013-01-01

    In 2012, the School District of Philadelphia closed six schools. In 2013, it closed 24. The closure of 30 schools has occurred amid a financial crisis, headlined by the district's $1.35 billion deficit. School closures are one piece of the district's plan to cut expenditures and close its budget gap. The closures are also intended to make…

  8. Proposed minimum requirements for the operational characteristics and testing of closed circuit life support system control electronics.

    Science.gov (United States)

    Kirk, J C

    1998-01-01

    The popularization and transformation of scuba diving into a broadly practiced sport has served to ignite the interest of technically oriented divers into ever more demanding areas. This, along with the gradual release of military data, equipment, and techniques of closed circuit underwater breathing apparatus, has resulted in a virtual explosion of semiclosed and closed circuit systems for divers. Although many of these systems have been carefully thought out by capable designers, the impulse to rush to market with equipment that has not been fully developed and carefully tested is irresistible to marketers. In addition, the presence of systems developed by well-intentioned and otherwise competent designers who are, nonetheless, inexperienced in the field of life support can result in the sale of failure-prone equipment to divers who lack the knowledge and skills to identify deficiencies before disaster occurs. For this reason, a set of industry standards establishing minimum requirements and testing is needed to guide the designers of this equipment, and to protect the user community from incomplete or inadequate design. Many different technologies go into the development of closed circuit scuba. One key area is the design of electronics to monitor and maintain the critical gas mixtures of the closed circuit loop. Much of the system reliability and inherent danger is resident in the design of the circuitry and the software (if any) that runs it. This article will present a set of proposed minimum requirements, with the goal of establishing a dialog for the creation of guidelines for the classification, rating, design, and testing of embedded electronics for life support systems used in closed circuit applications. These guidelines will serve as the foundation for the later creation of a set of industry specifications.

  9. Mining face equipment

    Energy Technology Data Exchange (ETDEWEB)

    G, Litvinskiy G; Babyuk, G V; Yakovenko, V A

    1981-01-07

    Mining face equipment includes drilling advance wells, drilling using explosives on the contour bore holes, loading and transporting the crushed mass, drilling reinforcement shafts, injecting reinforcement compounds and moving the timber. Camouflet explosives are used to form relaxed rock stress beyond the mining area to decrease costs of reinforcing the mining area by using nonstressed rock in the advance well as support. The strengthening solution is injected through advanced cementing wells before drilling the contour bores as well as through radial cementing wells beyond the timbers following loading and transport of the mining debris. The advance well is 50-80 m.

  10. Management of Transportation Equipment.

    Science.gov (United States)

    1982-11-01

    Record% % %. "jP -M -. M LIh TRANSPORTATION MAENTKENAI4CE SHOP WORKLOAD CONTROL WORK CENTER SADR A-OR .a’* tLR 4.,R53 8114LM 0 o 251 50 75 100 125 ISO ...PDBP 06 7 4892 TRACTOR, WHEEL, INDUST, 14001-20000 PDBP 06 7 4893 TRACTOR, WHEEL, INDUST, 20001-27000 PDBP 06 7 4894 TRACTOR, WHEEL, INDUST, 27001 PDBP...27K TRACTOR, WHEEL, INDUST, 27001 PDBP & UP P-i LINE ITEM 07 LIGHTING AND POWER GENERATION EQUIPMENT 5110 T FLOODLIGHT ELEC FLOODLIGHT, ELEC, TRUCK

  11. Californium-252 Program Equipment Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Chattin, Fred Rhea [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wilson, Kenton [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ezold, Julie G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-12-01

    To successfully continue the 252Cf production and meet the needs of the customers, a comprehensive evaluation of the Building 7920 processing equipment was requested to identify equipment critical to the operational continuity of the program.

  12. Model-independent and fast determination of optical functions in storage rings via multiturn and closed-orbit data

    Directory of Open Access Journals (Sweden)

    Bernard Riemann

    2011-06-01

    Full Text Available Multiturn (or turn-by-turn data acquisition has proven to be a new source of direct measurements for Twiss parameters in storage rings. On the other hand, closed-orbit measurements are a long-known tool for analyzing closed-orbit perturbations with conventional beam position monitor (BPM systems and are necessarily available at every storage ring. This paper aims at combining the advantages of multiturn measurements and closed-orbit data. We show that only two multiturn BPMs and four correctors in one localized drift space in the storage ring (diagnostic drift are sufficient for model-independent and absolute measuring of β and φ functions at all BPMs, including the conventional ones, instead of requiring all BPMs being equipped with multiturn electronics.

  13. Model-independent and fast determination of optical functions in storage rings via multiturn and closed-orbit data

    Science.gov (United States)

    Riemann, Bernard; Grete, Patrick; Weis, Thomas

    2011-06-01

    Multiturn (or turn-by-turn) data acquisition has proven to be a new source of direct measurements for Twiss parameters in storage rings. On the other hand, closed-orbit measurements are a long-known tool for analyzing closed-orbit perturbations with conventional beam position monitor (BPM) systems and are necessarily available at every storage ring. This paper aims at combining the advantages of multiturn measurements and closed-orbit data. We show that only two multiturn BPMs and four correctors in one localized drift space in the storage ring (diagnostic drift) are sufficient for model-independent and absolute measuring of β and φ functions at all BPMs, including the conventional ones, instead of requiring all BPMs being equipped with multiturn electronics.

  14. The organization closed water battery plant Aircraft Factory

    Directory of Open Access Journals (Sweden)

    В.М. Ісаєнко

    2008-01-01

    Full Text Available  The information on unrational water usage and losts is given in the article. The necessity of closed water cycle introduction is shown for the aircraft repairing plant. The principle scheme of closed cycle water usage is developed for the accumulator department of the aircraft repairing plant. Modern technological equipment is offered for implementation.

  15. Equipment support for the implementation of safeguards

    International Nuclear Information System (INIS)

    Arlt, R.; Bosler, G.; Goldfarb, M.; Schanfein, M.; Whichello, J.

    2001-01-01

    Full text: The provision of effective, reliable, and user-friendly equipment needed for the implementation of safeguards is one of the main objectives of the Division of Technical Services (SOTS) in the Department of Safeguards. As an outcome of a review by an independent external consultant firm, the instrumentation sections of the SGTS were reorganized in January 2001 into two new sections, the Section for NDA Systems and Seals (TNS) and Section for Installed Systems (TIE). Each section has 'cradle-to-grave' responsibilities for development, implementation, maintenance, and decommissioning of safeguards instruments and measurement systems. Unattended assay, monitoring and surveillance instruments are the responsibility of TIE while attended nondestructive assay (NDA) instruments and seals are handled by TNS. The principal goals of both sections are to define equipment requirements based on Departmental needs, to coordinate Support Programme tasks concerning development and implementation activities, to provide system engineering of commercial components, manage laboratory and to do field testing and prove system suitability for defined safeguards applications. In addition both sections coordinate equipment and supply needs for the Department, including acquisition, preparation, servicing, installation, commissioning, troubleshooting, maintenance and repair, ensuring their availability when needed. As required, TIE and TNS provide specialized field support to the Operations Divisions. Each section is working to standardize equipment as much as possible and reduce the number of instruments performing the same function. This reduces both inspector and technician training, required parts inventories, and overall life-cycle costs. Development based on User Needs from the Operations Divisions follows a strict quality control program that includes a thorough qualification testing procedure with the last phase being field-testing under actual facility conditions. A

  16. A Study of Parallels Between Antarctica South Pole Traverse Equipment and Lunar/Mars Surface Systems

    Science.gov (United States)

    Mueller, Robert P.; Hoffman, Stephen, J.; Thur, Paul

    2010-01-01

    The parallels between an actual Antarctica South Pole re-supply traverse conducted by the National Science Foundation (NSF) Office of Polar Programs in 2009 have been studied with respect to the latest mission architecture concepts being generated by the United States National Aeronautics and Space Administration (NASA) for lunar and Mars surface systems scenarios. The challenges faced by both endeavors are similar since they must both deliver equipment and supplies to support operations in an extreme environment with little margin for error in order to be successful. By carefully and closely monitoring the manifesting and operational support equipment lists which will enable this South Pole traverse, functional areas have been identified. The equipment required to support these functions will be listed with relevant properties such as mass, volume, spare parts and maintenance schedules. This equipment will be compared to space systems currently in use and projected to be required to support equivalent and parallel functions in Lunar and Mars missions in order to provide a level of realistic benchmarking. Space operations have historically required significant amounts of support equipment and tools to operate and maintain the space systems that are the primary focus of the mission. By gaining insight and expertise in Antarctic South Pole traverses, space missions can use the experience gained over the last half century of Antarctic operations in order to design for operations, maintenance, dual use, robustness and safety which will result in a more cost effective, user friendly, and lower risk surface system on the Moon and Mars. It is anticipated that the U.S Antarctic Program (USAP) will also realize benefits for this interaction with NASA in at least two areas: an understanding of how NASA plans and carries out its missions and possible improved efficiency through factors such as weight savings, alternative technologies, or modifications in training and

  17. Characterization equipment essential drawing plan

    International Nuclear Information System (INIS)

    WILSON, G.W.

    1999-01-01

    The purpose of this document is to list the Characterization equipment drawings that are classified as Essential Drawings. Essential Drawings: Are those drawings identified by the facility staff as necessary to directly support the safe operation of the facility or equipment (HNF 1997a). The Characterization equipment drawings identified in this report are deemed essential drawings as defined in HNF-PRO-242, Engineering Drawing Requirements (HNF 1997a). These drawings will be prepared, revised, and maintained per HNF-PRO-440, Engineering Document Change Control (HNF 1997b). All other Characterization equipment drawings not identified in this document will be considered Support drawings until the Characterization Equipment Drawing Evaluation Report is completed

  18. Coal mining equipment

    International Nuclear Information System (INIS)

    Stein, R.R.; Martin, T.W.

    1991-01-01

    The word in longwall components is big, and these larger components have price tags to match. The logic behind the greater investment is that it will yield high production rates and good uptime statistics. This is true in most cases. More important than single-shift tonnage records, average shift production continues to climb upwards. This paper reports on the quality, and more significantly, the quantity of service supplied for long-wall equipment, which has reached levels that would have been seen as unachievable when longwall mining was first introduced in the U.S. The school of thought then was that longwall would increase productivity in part by reducing the number of production units and thus reducing the number of personnel employed underground. The expectation of fewer employees turned out to be unrealistic. That was probably one reason that some early attempts to install longwall system looked more like failures than vision of the future

  19. Reactor fuel charging equipment

    International Nuclear Information System (INIS)

    Wade, Elman.

    1977-01-01

    In many types of reactor fuel charging equipment, tongs or a grab, attached to a trolley, housed in a guide duct, can be used for withdrawing from the core a selected spent fuel assembly or to place a new fuel assembly in the core. In these facilities, the trolley may have wheels that roll on rails in the guide duct. This ensures the correct alignment of the grab, the trolley and fuel assembly when this fuel assembly is being moved. By raising or lowering such a fuel assembly, the trolley can be immerged in the coolant bath of the reactor, whereas at other times it can be at a certain level above the upper surface of the coolant bath. The main object of the invention is to create a fuel handling apparatus for a sodium cooled reactor with bearings lubricated by the sodium coolant and in which the contamination of these bearings is prevented [fr

  20. Chapter 12. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  1. Lessons learned in testing of Safeguards equipment

    International Nuclear Information System (INIS)

    Pepper, Susan; Farnitano, Michael; Carelli, Joseph

    2001-01-01

    Full text: During the 1990s, the IAEA Department of Safeguards began a transition from analog to digital equipment. This included surveillance equipment, seals, NDA measurement systems, and other instruments. The transition to digital equipment was intended to facilitate compatibility between and integration of instruments, remote communication of data, improved data storage, and modernization. Many of the instruments are designed to operate on battery power during loss of facility power, and therefore, are designed to consume minimal power. In 2000, the IAEA experienced a number of failures in digital image surveillance (DIS) equipment. A study of the performance data revealed that the failures occurred in 'high risk' environments where the systems were exposed to neutrons. As a supporter of IAEA equipment development and implementation, the U.S. Support Program worked with the IAEA, the equipment designer, and the equipment manufacturer in special meetings on DIS to determine the cause of the failures. It was as a result of these meetings that single event upset (SEU) was determined to be the root cause of the failures. The meeting participants also identified a list of actions to improve the reliability of DIS systems. As a result of the DIS meetings and the identified actions, the U.S. Support Program approved a request from the IAEA and established Task E.125, 'Remote Monitoring and Unattended Digital Surveillance Systems.' This task is an umbrella task intended to provide a mechanism for response to IAEA needs related to improving the reliability of unattended, remote monitoring and DIS equipment. Subtasks approved under this task include: E.125.1, 'SDIS Software Consolidation and DCM-14 Audit' - This subtask involves the consolidation of a number of individual upgrades to the SDIS and review of the DCM-14 software. As the sponsor of the design of the DCM-14 by Dr. Neumann, the German Support Program is also a participant in this subtask; E.125.2, 'DIS

  2. Restaurants closed over Christmas

    CERN Multimedia

    2011-01-01

    The restaurants will be closed during the Christmas holiday period : please note that all three CERN Restaurants will be closed from 5 p.m. on Wednesday, 21 December until Wednesday, 4 January inclusive. The Restaurants will reopen on Thursday, 5 January 2012.

  3. Adventitious X-radiation from high voltage equipment

    International Nuclear Information System (INIS)

    Martin, E.B.M.

    1979-01-01

    The monograph is concerned with hazards of unwanted x-rays from sources such as television receivers, high voltage equipment, radar transmitters, switchgear and electron beam apparatus for welding, evaporation, analysis and microscopy. Chapters are included on units, production of x radiation, biological effects, protection standards, radiation monitoring, shielding and control of access, medical and dosimetric supervision and types of equipment. A bibliography of 92 references and other cited literature is included. (U.K.)

  4. Radiation monitoring system

    International Nuclear Information System (INIS)

    Takeuchi, Nobuyoshi; Fujimoto, Toshiaki; Nagama, Hideyo

    2007-01-01

    A positive outlook toward nuclear power plants and a higher level of technologies for using radiation in the medical field are trends that are spreading throughout the world, and as a consequence, demand is increasing for equipment and systems that measure and control radiation. Equipment ranging from radiation detection and measurement devices to computer-based radiation management systems will be set up in overseas. Products that depend on overseas specifications based on IEC and other international standards are being developed. Fuji Electric is advancing the overseas deployment of radiation monitoring systems by adopting measures that will ensure the reliability and traceability of radiation equipment. (author)

  5. Equipment repair in coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, S

    1982-01-01

    Most equipment in Chinese coal mines consists of machinery and equipment produced in the 1950s; the efficiency of 4-62, CTD-57 and 70B/sub 2/ ventilators is 15% lower than that of new ones; that of SSM and AYaP pumps, 10% lower than of modern ones. Equipment renovation is done in three ways: replacing obsolete equipment with new equipment of the same type; improving the performance of existing equipment by introducing efficiency and reconstruction; and replacing obsolete equipment with advanced equipment. It is indicated that the second way, for example, replacement of 4-62 ventilator blades with a maximum efficiency of 73% by 4-72 ventilator blades raises its efficiency to 90%. Replacing the 8DA-8x3 water pump, having a maximum efficiency of 63%, with the 200D 43x3 pump with a maximum efficiency of 78%, enables an electricity savings of 7000 yuan per year, which exceeds all replacement costs (600 yuan). The need to improve equipment maintenance and preventive work to increase equipment service life and to introduce new techniques and efficiency is noted.

  6. The design and qualification of radiation tolerant equipment for the nuclear power industry

    International Nuclear Information System (INIS)

    Sharp, R.; Pater, L.

    1995-01-01

    The nuclear power industry has many demands for equipment tolerant to the damaging effects of radiation. The wide variety of applications, including components handling, tooling, monitoring and communications, means that a systematic evaluation of the effects of radiation on materials and components used for equipment in radioactive facilities is often required. This paper describes the various effects of radiation on equipment, and discusses how to manage them when using and designing equipment. (Author)

  7. Equipment aging: an overview of status and research needs

    International Nuclear Information System (INIS)

    Carfagno, S.P.

    1982-01-01

    The problem of equipment aging in nuclear power generating stations is viewed from the standpoint of the qualification of safety-related equipment. A brief summary of developments related to equipment aging and qualification (in industry, the regulatory arena, and in the research area) is presented to focus on the current status of the problem. Several research topics are suggested for consideration as components of any general plan of research on plant aging. Among these is a topic concerned with an effort to establish the relative merit of different approaches to account for the functional degradation of equipment in terms of their cost and their contribution to assurance of public safety and a topic to investigate ways to improve the monitoring of functional degradation of equipment in service. Some factors to be considered in choosing among research topics and in establishing funding levels are mentioned

  8. 21 CFR 866.4540 - Immunonephelometer equipment.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4540 Immunonephelometer equipment. (a) Identification. Immunonephelometer equipment for clinical use...

  9. 21 CFR 866.4520 - Immunofluorometer equipment.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4520 Immunofluorometer equipment. (a) Identification. Immunofluorometer equipment for clinical use with...

  10. Radiation contamination monitors

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Iba, Hiroshi; Sato, Hiroshi

    1999-01-01

    To make sure of no contamination on people, used articles and working uniforms coming out of the radiation controlled area, nuclear power plants are equipped with radioactive contamination monitors. This paper outlines the basic specifications and advantages of our personnel surface contamination monitors to inspect whole-body surface contamination of people coming out, article surface contamination monitors to inspect the surface and inside contamination of used articles brought out, laundry monitors to inspect surface contamination of working uniforms used in the area before and after a wash, and whole-body counters to inspect and measure the internal contamination of a person out of the area. (author)

  11. Equipment standards for interventional cardiology

    International Nuclear Information System (INIS)

    Dowling, A.; Gallagher, A.; Walsh, C.; Malone, J.

    2005-01-01

    Interventional radiology has seen rapid growth in cardiology and represents an alternative to hazardous surgery. Recently there has been a substantial growth in the number of procedures being performed and interventional cardiology (IC) procedures are the most common interventional procedures in Europe. Advances in imaging technology have facilitated the development of increasingly complex radiological IC equipment. Currently, the technology is developing at a rate ahead of supporting research, equipment standards and a regulatory framework. International standards play a key role in the design, manufacture and performance of radiological IC equipment. A survey of 12 IC systems (15 imaging chains) was conducted in Irish hospitals. The aim of the study was to assess the imbalance between rapidly advancing technology and existing standards and to propose recommendations for new IC equipment standards. The results demonstrate the need for definitive equipment requirements and standardisation in the design, manufacture, acceptance and maintenance of IC equipment. (authors)

  12. Closed string field theory

    International Nuclear Information System (INIS)

    Strominger, A.

    1987-01-01

    A gauge invariant cubic action describing bosonic closed string field theory is constructed. The gauge symmetries include local spacetime diffeomorphisms. The conventional closed string spectrum and trilinear couplings are reproduced after spontaneous symmetry breaking. The action S is constructed from the usual ''open string'' field of ghost number minus one half. It is given by the associator of the string field product which is non-vanishing because of associativity anomalies. S does not describe open string propagation because open string states associate and can thereby be shifted away. A field theory of closed and open strings can be obtained by adding to S the cubic open string action. (orig.)

  13. Generation of equipment response spectrum considering equipment-structure interaction

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Yoo, Kwang Hoon

    2005-01-01

    Floor response spectra for dynamic response of subsystem such as equipment, or piping in nuclear power plant are usually generated without considering dynamic interaction between main structure and subsystem. Since the dynamic structural response generally has the narrow-banded shapes, the resulting floor response spectra developed for various locations in the structure usually have high spectral peak amplitudes in the narrow frequency bands corresponding to the natural frequencies of the structural system. The application of such spectra for design of subsystems often leads to excessive design conservatisms, especially when the equipment frequency and structure are at resonance condition. Thus, in order to provide a rational and realistic design input for dynamic analysis and design of equipment, dynamic equipment-structure interaction (ESI) should be considered in developing equipment response spectrum which is particularly important for equipment at the resonance condition. Many analytical methods have been proposed in the past for developing equipment response spectra considering ESI. However, most of these methods have not been adapted to the practical applications because of either the complexities or the lack of rigorousness of the methods. At one hand, mass ratio among the equipment and structure was used as an important parameter to obtain equipment response spectra. Similarly, Tseng has also proposed the analytical method for developing equipment response spectra using mass ratio in the frequency domain. This method is analytically rigorous and can be easily validated. It is based on the dynamic substructuring method as applied to the dynamic soil-structure interaction (SSI) analysis, and can relatively easily be implemented for practical applications without to change the current dynamic analysis and design practice for subsystems. The equipment response spectra derived in this study are also based on Tseng's proposed method

  14. Operation control equipment for BWR type reactor

    International Nuclear Information System (INIS)

    Izumi, Masayuki; Takeda, Renzo.

    1981-01-01

    Purpose: To improve the temperature balance in a feedwater heater by obtaining the objective value of a feedwater enthalpy upon calculation of respective measured values and controlling the opening or closing of an extraction valve so that the objective value may coincide with the measured value, thereby averaging the axial power distribution. Constitution: A plurality of stages of extraction lines are connected to a turbine, and extraction valves are respectively provided at the lines. By calculating the measured values of ractor pressure, reactor core flow rate, vapor flow rate and reactor core inlet enthalpy determined to predetermined value using heat balance the objective feedwater enthalpy is obtained, is fed as an extraction valve opening or closing signal from a control equipment, the extraction stages of the turbine extraction are altered in accordance with this signal, and the feedwater enthalpy is controlled. (Sekiya, K.)

  15. Information technology equipment cooling system

    Science.gov (United States)

    Schultz, Mark D.

    2014-06-10

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

  16. Management methodology for pressure equipment

    Science.gov (United States)

    Bletchly, P. J.

    Pressure equipment constitutes a significant investment in capital and a major proportion of potential high-risk plant in many operations and this is particularly so in an alumina refinery. In many jurisdictions pressure equipment is also subject to statutory regulation that imposes obligations on Owners of the equipment with respect to workplace safety. Most modern technical standards and industry codes of practice employ a risk-based approach to support better decision making with respect to pressure equipment. For a management system to be effective it must demonstrate that risk is being managed within acceptable limits.

  17. Cryogenic equipment; Materiel cryogenique

    Energy Technology Data Exchange (ETDEWEB)

    Leger, L; Javellaud, J; Caro, C; Gilguy, R; Testard, O

    1966-06-01

    The cryostats presented here were built from standard parts; this makes it possible to construct a great variety of apparatus at minimum cost. The liquid nitrogen and helium reservoirs were designed so as to reduce losses to a minimum, and so as to make the cryostats as autonomous as possible. The experimental enclosure which is generally placed in the lower part of the apparatus requires a separate study in every case. Furthermore, complete assemblies such as transfer rods, isolated traps and high vacuum valves, were designed with a similar regard for the economic aspects and for the need for standardization. This equipment thus satisfies a great variety of experimental needs; it is readily adaptable and the consumptions of helium and liquid nitrogen are very low. (authors) [French] De nombreuses experiences utilisant les basses temperatures, necessitent l'emploi d'un materiel cryogenique complexe n'existant pas dans le commerce. Les cryostats presentes ici ont ete realises a partir d'elements standard, ce qui permet, malgre la diversite des appareils, de realiser un ensemble a moindre frais. Les reservoirs d'azote et d'helium liquides ont ete concus de facon a limiter les pertes et a conferer au cryostat la plus grande autonomie possible. L'enceinte experimentale situee en general dans la partie inferieure de l'appareil necessite dans tous les cas une etude speciale. D'autre part des ensembles complets tels que les cannes de transfert, piege isole, robinet pour vide secondaire, ont ete concus dans le meme souci de rentabilite et de standardisation. Ce materiel peut donc repondre a un grand nombre d'exigences experimentales, il est facilement adaptable, et les consommations d'helium et d'azote liquide sont tres reduites. (auteurs)

  18. 29 CFR 1926.952 - Mechanical equipment.

    Science.gov (United States)

    2010-07-01

    ... equipment that are not covered with insulating protective equipment. (c) Derrick trucks, cranes and other lifting equipment. (1) All derrick trucks, cranes and other lifting equipment shall comply with subpart N...

  19. 22 CFR 135.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  20. 21 CFR 1403.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  1. 45 CFR 602.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  2. 49 CFR 18.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  3. 34 CFR 80.32 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  4. 10 CFR 600.232 - Equipment.

    Science.gov (United States)

    2010-01-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  5. 45 CFR 1183.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  6. Radiation levels at CERN's injectors and their impact on electronic equipment

    CERN Document Server

    AUTHOR|(SzGeCERN)649218; Brugger, Markus

    2013-01-01

    Electronic devices operating in hostile radiation environments, such as those found close to high-energy particle accelerators, can suffer from different types of radiation induced failures. At CERN, the mixed particle and energy radiation fields present at the Large Hadron Collider (LHC) and its injector chain can give rise to both stochastic and cumulative effects causing radiation induced failures of exposed electronics and materials, thus directly impacting components and system lifetimes, as well as maintenance requirements. With its original focus on the LHC, the Radiation to Electronics (R2E) project has been successfully implementing mitigation actions in order to avoid accelerator downtime due to radiation induced failures on active electronics. In a next step, the emphasis is put on CERN's injector chain, collecting the respective available information about radiation levels, the definition of additional monitoring requirements and a critical analysis of present and future equipment installations. T...

  7. Developing Software For Monitoring And Diagnosis

    Science.gov (United States)

    Edwards, S. J.; Caglayan, A. K.

    1993-01-01

    Expert-system software shell produces executable code. Report discusses beginning phase of research directed toward development of artificial intelligence for real-time monitoring of, and diagnosis of faults in, complicated systems of equipment. Motivated by need for onboard monitoring and diagnosis of electronic sensing and controlling systems of advanced aircraft. Also applicable to such equipment systems as refineries, factories, and powerplants.

  8. Food Service Equipment and Appurtenances.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI.

    Equipment design specifications are presented relating to tables of all kinds, counters, sinks and drainboards, bins, shelves, drawers, hoods and similar kitchen appurtenances, not including baking, roasting, toasting, broiling or frying equipment, food preparation machinery such as slicers, choppers, and cutters, mixers and grinders, steam…

  9. Equipment reliability improvement process; implementation in Almaraz NPP and Trillo NPP

    International Nuclear Information System (INIS)

    Risquez Bailon, Aranzazu; Gutierrez Fernandez, Eduardo

    2010-01-01

    The Equipment Reliability Improvement Process (INPO AP-913) is a non-regulatory process developed by the US Nuclear Industry for improving Plants Availability. This Process integrates and coordinates a broad range of equipment reliability activities into one process, performed by the Plant in a non-centralized way. The integration and coordination of these activities will allow plant personnel to evaluate the trends of important station equipment, develop and implement long-term equipment health plans, monitor equipment performance and condition, and make adjustments to preventive maintenance tasks and frequencies based on equipment operating experience, if necessary, arbitrating operational and design improvements, to reach a Failure-free Operation. This paper describes the methodology of Equipment Reliability Improvement Process, being focused on main aspects of the implementation process, relating to the scope and establishment of an Equipment Reliability Monitoring Plan, which should include and complement the existing mechanisms and organizations in the Plant to monitor the condition and performance of the equipments, with the common aim of achieving an operation free of failures. The paper will describe the tools that Iberdrola Ingenieria has developed to support the implementation and monitoring of the Equipment Reliability Improvement Process, as well as the results and lessons learned from its implementation in Almaraz NPP and Trillo NPP. (authors)

  10. Equipe de trabalho

    Directory of Open Access Journals (Sweden)

    Gabriel Gerber Hornink

    2014-08-01

    Full Text Available   Equipe de Trabalho 2014 1. Equipe editorial Editor-Chefe Bayardo Bapstista Torres, Instituto de Química - USP, Brasil Eduardo Galembeck, Departamento de Bioquímica Instituto de Biologia UNICAMP, Brasil   Editores Gabriel Gerber Hornink, Depto. Bioquímica, Instituto de Ciências Biomédicas, Universidade - Federal de Alfenas - Unifal-MG, Brasil Vera Maria Treis Trindade, Instituto de Ciências Básicas da Saúde, Departamento de Bioquímica, Universidade Federal do Rio Grande do Sul, Brasil   Corpo Editorial Adriana Cassina, Departamento de Bioquímica, Facultad de Medicina, Universidad de la República, Uruguai Angel Herráez, Departamento de Bioquímica y Biología molecular, Universidad de Alcalá de Henares, Madrid, Espanha André Amaral Gonçalves Bianco, Universidade Federal de São Paulo (Unifesp, Brasil Denise Vaz de Macedo, Departamento de Bioquímica, Instituto de Biologia, Universidade Estadual de Campinas - Unicamp, Brasil Eneida de Paula, Departamento de Bioquímica, Instituto de Biologia, Universidade Estadual de Campinas - Unicamp, Brasil Guilherme Andrade Marson, Instituto de Química - USP, Brasil Jose Antonio Martinez Oyanedel, Universidad de Concepción, Chile Josep Maria Fernández Novell, Dept. Bioquímica i Biologia Molecular Universitat de Barcelona, Espanha Leila Maria Beltramini, Instituto de Física de São Carlos, Universidade Estadual de São Paulo - USP, Brasil Manuel João da Costa, Escola de Ciências da Saúde, Universidade do Minho, Portugal Maria Lucia Bianconi, Instituto de Bioquímica Médica Universidade Federal do Rio de Janeiro (UFRJ, Brasil María Noel Alvarez, Departamento de Bioquímica, Facultad de Medicina, Universidad de la República, Uruguai Miguel Ángel Medina Torres, Department of Molecular Biology & Biochemistry Faculty of Sciences University of Málaga, Espanha Nelma Regina Segnini Bossolan, Instituto de Física de São Carlos, Universidade de São Paulo - USP, Brasil Paulo De Avila

  11. 2006 equipment evolutions

    Energy Technology Data Exchange (ETDEWEB)

    McArdle, D. [KMC Mining, Edmonton, AB (Canada)

    2006-07-01

    KMC Mining is a privately-owned major mining contractor that was established in 1949. The company has a long history in construction of roads; railroads; dams; and other major earthworks. It is primarily involved in Alberta oilsands, although it has also performed elsewhere in northern and western Canada. This presentation provided a corporate overview of KMC Mining and discussed its fleet profile, operations and an overview of its South Tailings Pond Project. The company added 7 new 320 ton class haul trucks to its fleet in 2005 to match its shovel capacity. The presentation provided an overview of 3 separate incidents in 2005 that resulted in damage to the frame and steering linkage; tie-rod failure with both front struts separated from a truck; and tie-rod failure with left hand front strut separated from a truck. These incidents were described in detail and post-investigations were conducted. As a result of this investigation, some possible incident contributors were also discussed. Next, the presentation discussed mounting hardware and provided an overview of hardware failure and replacement hardware. Last, the presentation addressed incident reoccurrence mitigation. A reoccurrence prevention plan was developed, which included suspension mounting hardware; tie-rod inspection and re-design; and payload monitoring and operating practices. It was summarized that measures are still in place since the reoccurrence prevention plan and there have been no further incidents. figs.

  12. Information technology equipment cooling method

    Science.gov (United States)

    Schultz, Mark D.

    2015-10-20

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools air utilized by the rack of information technology equipment to cool the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat generated by the rack of information technology equipment.

  13. Prediction of hygiene in food processing equipment using flow modelling

    DEFF Research Database (Denmark)

    Friis, Alan; Jensen, Bo Boye Busk

    2002-01-01

    Computational fluid dynamics (CFD) has been applied to investigate the design of closed process equipment with respect to cleanability. The CFD simulations were validated using the standardized cleaning test proposed by the European Hygienic Engineering and Design Group. CFD has been proven as a ...

  14. Minding the close relationship.

    Science.gov (United States)

    Harvey, J H; Omarzu, J

    1997-01-01

    In this theoretical analysis, we argue that a process referred to as minding is essential for a couple to feel mutually close and satisfied in a close relationship over a long period Minding represents a package of mutual self-disclosure, other forms of goal-oriented behavior aimed at facilitating the relationship, and attributions about self's and other's motivations, intentions, and Mort in the relationship. Self-disclosure and attribution activities in minding are aimed at getting to know the other, trying to understand the other's motivations and deeper disposition as they pertain to the relationship, and showing respect and acceptance for knowledge gained about other. We link the concept of minding to other major ideas and literatures about how couples achieve closeness: self-disclosure and social penetration, intimacy, empathy and empathic accuracy, and love and self-expansion. We argue that the minding process articulated here has not previously been delineated and that it is a useful composite notion about essential steps in bonding among humans. We also argue that the minding concept stretches our understanding of the interface of attribution and close relationships. We present research possibilities and implications and consider possible alternative positions and counter arguments about the merits of the minding idea for close relationship satisfaction.

  15. Project management in nuclear equipment manufacture

    International Nuclear Information System (INIS)

    Liu Jiancheng

    2005-01-01

    The completion of the management organization shall be firstly considered in project management for a nuclear power plant. The organization of nuclear equipment quality assurance program and project management consists of 5 departments such as the nuclear power container department, the manufacture department and the quality assurance department. The general manager takes the overall responsibility for the quality of the nuclear press usr bearing equipment, and the vice general manager takes responsibility for the quality, technology and schedule related with the manufacture of the equipment, and organizes the organization department for the audit. The director of the quality assurance department takes the responsibility for the establishment and completion of the quality assurance program, with enough rights authorized by the general manager, including the right not bounded by the cost and schedule, and confirms the implementation of the program by related departments and personnel. The manufacture schedule shall be prepared to ensure the implementation feasibility, process continuity and flexibility. The schedule shall be followed and monitored for the whole process, to check and feedback the implementation. (authors)

  16. Using operational equipment to read accident dosemeters.

    Science.gov (United States)

    Devine, R T; Vigil, M M; Martinez, W A

    2004-01-01

    Analysis of accident dosemeters usually involves the use of laboratory-based counting equipment. Gamma spectrometers are used for indium, copper and gold, and alpha-beta detectors for sulphur. This equipment is usually not easily transported due to the shielding required and the weight and delicacy of the counters. For intercomparison studies that require reading the dosemeters on site, a transportable system is required unless the site operating the study can count samples for all the participants. In the case of an actual accident these systems would have a difficulty in counting a large number of accident dosemeters. In an accident, personnel are usually subdivided according to their level of exposure. Those exposed to higher doses are treated immediately. An alternate system should be made available to handle the dosemeters worn by those personnel are likely to receive lower doses. Improvements in portable operational equipment for gamma and beta monitoring allow their use as spectrometers. Such a system was used for the SILENE intercomparison conducted at IRSN Valduc on 12 June and 19, 2002, and the preliminary results compared well with the other participants.

  17. Close binary stars

    International Nuclear Information System (INIS)

    Larsson-Leander, G.

    1979-01-01

    Studies of close binary stars are being persued more vigorously than ever, with about 3000 research papers and notes pertaining to the field being published during the triennium 1976-1978. Many major advances and spectacular discoveries were made, mostly due to increased observational efficiency and precision, especially in the X-ray, radio, and ultraviolet domains. Progress reports are presented in the following areas: observational techniques, methods of analyzing light curves, observational data, physical data, structure and models of close binaries, statistical investigations, and origin and evolution of close binaries. Reports from the Coordinates Programs Committee, the Committee for Extra-Terrestrial Observations and the Working Group on RS CVn binaries are included. (Auth./C.F.)

  18. Radiation monitor reporting requirements

    International Nuclear Information System (INIS)

    Bates, W.F.

    1993-01-01

    Within High-Level Waste Management (HLWM), CAMs and VAMPs are currently considered Class B equipment, therefore, alarm conditions associated with the CAMs and VAMPs result in an Unusual Occurrence or Off-Normal notification and subsequent occurrence reporting. Recent equipment difficulties associated with Continuous Air Monitors (CAMs) and Victoreen Area Radiation Monitors (VAMPs) have resulted in a significant number of notification reports. These notification have the potential to decrease operator sensitivity to the significance of specific CAM and VAMP failures. Additionally, the reports are extremely costly and are not appropriate as a means for tracking and trending equipment performance. This report provides a technical basis for a change in Waste Management occurrence reporting categorization for specific CAM and VAMP failure modes

  19. Strategic plan for the development of IAEA safeguards equipment

    International Nuclear Information System (INIS)

    Khlebnikov, N.

    2001-01-01

    Full text: The need for a top-down Safeguards Strategy to focus departmental objectives was recognized by the Programme Performance Appraisal System (PPAS) performed on the Equipment Development Project in 1999. The Department of Safeguards prepared at the end of 2000 a 5-year Strategic Plan to identify the changes and improvements expected to take place over the 2001-2005 period. Those Strategic Objectives were supposed to be used to properly plan IAEA Safeguards activities and define appropriate and coherent R and D programmes. The present paper describes the strategic directions that the IAEA will follow in the area of equipment development in order to meet the Safeguards Department long-term objectives for 2001-2005. The paper, which is derived from the IAEA Strategic Equipment Development Plan, prepared by the Division of Technical Support, includes two parts: general principles and policies applicable to all equipment development tasks; specific strategic guidance. The paper will not describe the detailed plans which are prepared based on the strategic plan on a biannual basis. Equipment development activities have been divided in five major projects (NDA, Seals, Surveillance, Unattended Monitoring and Remote Monitoring). Strategic directions for each of these projects will be described in the paper. Separate sections will deal with equipment development strategic guidance in the area of additional protocol inspections, JNFL projects, illicit trafficking and Trilateral Initiative. (author)

  20. Slope stability radar for monitoring mine walls

    Science.gov (United States)

    Reeves, Bryan; Noon, David A.; Stickley, Glen F.; Longstaff, Dennis

    2001-11-01

    Determining slope stability in a mining operation is an important task. This is especially true when the mine workings are close to a potentially unstable slope. A common technique to determine slope stability is to monitor the small precursory movements, which occur prior to collapse. The slope stability radar has been developed to remotely scan a rock slope to continuously monitor the spatial deformation of the face. Using differential radar interferometry, the system can detect deformation movements of a rough wall with sub-millimeter accuracy, and with high spatial and temporal resolution. The effects of atmospheric variations and spurious signals can be reduced via signal processing means. The advantage of radar over other monitoring techniques is that it provides full area coverage without the need for mounted reflectors or equipment on the wall. In addition, the radar waves adequately penetrate through rain, dust and smoke to give reliable measurements, twenty-four hours a day. The system has been trialed at three open-cut coal mines in Australia, which demonstrated the potential for real-time monitoring of slope stability during active mining operations.

  1. Development of manufacturing equipment and QC equipment for DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Park, J.J.; Lee, J.W.; Kim, S.S.; Yim, S.P.; Kim, J.H.; Kim, K.H.; Na, S.H.; Kim, W.K.; Shin, J.M.; Lee, D.Y.; Cho, K.H.; Lee, Y.S.; Sohn, J.S.; Kim, M.J.

    1999-05-01

    In this study, DUPIC powder and pellet fabrication equipment, welding system, QC equipment, and fission gas treatment are developed to fabricate DUPIC fuel at IMEF M6 hot cell. The systems are improved to be suitable for remote operation and maintenance with the manipulator at hot cell. Powder and pellet fabrication equipment have been recently developed. The systems are under performance test to check remote operation and maintenance. Welding chamber and jigs are designed and developed to remotely weld DUPIC fuel rod with manipulators at hot cell. Remote quality control equipment are being tested for analysis and inspection of DUPIC fuel characteristics at hot cell. And trapping characteristics is analyzed for cesium and ruthenium released under oxidation/reduction and sintering processes. The design criteria and process flow diagram of fission gas treatment system are prepared incorporating the experimental results. The fission gas treatment system has been successfully manufactured. (Author). 33 refs., 14 tabs., 91 figs

  2. Special servicing equipment for reactor pressurized vessel stud hole and stud accessories

    International Nuclear Information System (INIS)

    Li Jianglian

    1999-01-01

    The author briefly introduces the design and manufacture of nuclear island special servicing equipment of Nuclear Power Institute of China. Maintenance process of reactor pressurized vessel (RPV) stud hold and stud accessories the special servicing equipment include RPV flange dummy, closed-circuit television (CCTV) inspection equipment, RPV stud hole expandable comb, RPV stud hole polisher, RPV stud hold thread lubricating equipment, RPV stud hole thread miller and RPV stud hole camera. It is presented how eight kinds of special servicing equipment perform the maintenance process concerning their function, structure, and characteristics, their practical use on site is also introduced

  3. NRC closing remarks

    International Nuclear Information System (INIS)

    Coffman, F.

    1994-01-01

    This section contains the edited transcript of the NRC closing remarks made by Mr. Franklin Coffman (Chief, Human Factors Branch, Office of Nuclear Regulatory Research) and Dr. Cecil Thomas (Deputy Director, Division of Reactor Controls and Human Factors, Office of Nuclear Reactor Regulation). This editing consisted of minimal editing to correct grammar and remove extraneous references to microphone volume, etc

  4. Radiation monitoring: an introduction. Rev. ed.

    International Nuclear Information System (INIS)

    Hayward, P.; Arnott, D.

    1987-01-01

    This Greenpeace pamphlet has been produced in reponse to requests from members of the public wishing to set up monitoring groups. It lists some U.K. manufacturers of radiation monitoring equipment and the contributors have summarized information available from manufacturer's own catalogues describing the equipment, what it will and will not do and costing various programmes. Three types of monitoring are discussed: monitoring the level of background gamma radiation, monitoring radioactive contamination, (early warning systems), and monitoring food and environmental samples for very low levels of radiation. (UK)

  5. TRANSPORT AND EMPLACEMENT EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    1997-01-01

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) Transport and Emplacement in the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. The Transport and Emplacement equipment described in this document consists of the following: (1) WP Transporter; (2) Reusable Rail Car; (3) Emplacement Gantry; (4) Gantry Carrier; and (5) Transport Locomotive

  6. New equipment for the needs of mobile automatic ultrasonic testing

    International Nuclear Information System (INIS)

    Cost, H.; Vogt, M.

    1989-01-01

    A newly designed system of equipment - ECHOGRAPH 1030 MULTI - for multiplex operation is introduced. The frequency control unit which can distribute a pulse sequency frequency from a maximum of 8 KHz to up to 8 cycles and the monitor evaluation, are described. (MM) [de

  7. Evaluation of Occupational Closed Globe Eye Injuries

    Directory of Open Access Journals (Sweden)

    Berna Akova-Budak

    2016-01-01

    Full Text Available Aim: To evaluate closed glob injuries related to occupational accidents of patients who had official occupational accident records. Material and Method: The medical records of patients with ocular injuries who referred to Department of Ophthalmology or emergency of Uludag University, School of Medicine between January 2010 and December 2013 with official occupational accident report were retrospectively reviewed. The patients with closed globe injuries following trauma were included. Age, sex, the injured eye, the cause of the trauma, whether the precautions were taken or not by the patient, the damage due to trauma were recorded. Results: According to the official records, 108 patients referred to our clinic with closed globe injury related to occupational accident. One hundred twenty eyes of 108 patients ( 2 females, 106 males were evaluated. The mean age of the patients was 33±8.6 years. The most frequent cause of injury was foreign bodies on the ocular surface followed by blunt trauma. The mean age of the patients injured with foreign bodies was found to be significantly lower than the patients injured with blunt objects (p=0.039. Thirteen patients reported that they had used preventive equipment. Discussion: It is of utmost importance that the awareness of the workers should be raised and they should be educated about the use of preventive equipment to prevent the occupational eye injuries. The education of particularly the younger patients about the occupational injuries when they begin to work may decrease the rate of occupational accident related eye injuries.

  8. Quality and Safety of Home ICP Monitoring Compared with In-Hospital Monitoring

    DEFF Research Database (Denmark)

    Andresen, Morten; Juhler, Marianne; Munch, Tina Nørgaard

    2012-01-01

    Introduction: Intracranial pressure (ICP) monitoring is usually conducted in-hospital using stationary devices. Modern mobile ICP monitoring systems present new monitoring possibilities more closely following the patients' daily life. We reviewed patient safety, quality of technical data...

  9. From Site Characterization through Safe and Successful CO2 Injection Operation to Post-injection Monitoring and Site Closure - Closing the Full Life Cycle Research at the Ketzin Pilot Site, Germany

    Science.gov (United States)

    Liebscher, Axel

    2017-04-01

    Initiated in 2004, the Ketzin pilot site near Berlin, Germany, was the first European onshore storage project for research and development on geological CO2 storage. After comprehensive site characterization the site infrastructure was build comprising three deep wells and the injection facility including pumps and storage tanks. The operational CO2 injection period started in June 2008 and ended in August 2013 when the site entered the post-injection closure period. During these five years, a total amount of 67 kt of CO2 was safely injected into an Upper Triassic saline sandstone aquifer at a depth of 630 m - 650 m. In fall 2013, the first observation well was partially plugged in the reservoir section with CO2 resistant cement; full abandonment of this well finished in 2015 after roughly 2 years of cement plug monitoring. Abandonment of the remaining wells will be finished by summer 2017 and hand-over of liability to the competent authority is scheduled for end of 2017. The CO2 injected was mainly of food grade quality (purity > 99.9%). In addition, 1.5 kt of CO2 from the oxyfuel pilot capture facility "Schwarze Pumpe" (purity > 99.7%) was injected in 2011. The injection period terminated with a CO2-N2 co-injection experiment of 650 t of a 95% CO2/5% N2 mixture in summer 2013 to study the effects of impurities in the CO2 stream on the injection operation. During regular operation, the CO2 was pre-heated on-site to 40°C prior to injection to ensure a single-phase injection process and avoid any phase transition or transient states within the injection facility or the reservoir. Between March and July 2013, just prior to the CO2-N2 co-injection experiment, the injection temperature was stepwise decreased down to 10°C within a "cold-injection" experiment to study the effects of two-phase injection conditions. During injection operation, the combination of different geochemical and geophysical monitoring methods enabled detection and mapping of the spatial and

  10. EAS Equipment Authorization Grantee Registrations

    Data.gov (United States)

    Federal Communications Commission — EAS (Equipment Authorization System). Radio Frequency (RF) devices are required to be properly authorized under 47 CFR Part 2 prior to being marketed or imported...

  11. ENERGY STAR Certified Imaging Equipment

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 2.0 ENERGY STAR Program Requirements for Imaging Equipment that are effective as of...

  12. EMR Measurements on NDA Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Macdonell, Alexander Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Meierbachtol, Krista Cruse [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Evans, James Walter Jr. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mayo, Douglas R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-10

    Electromagnetic radiation (EMR) emission strength measurements were performed on a suite of passive non-destructive assay (NDA) radiation detection equipment. Data were collected from 9 kHz up to 6 GHz on each of the assembled systems.

  13. Mongolia - Vocational Education - Equipment Upgrades

    Data.gov (United States)

    Millennium Challenge Corporation — Evaluation design The impact evaluation sought to identify the causal impact of exposure to equipment upgrades on subsequent outcomes. Insofar as we were not able to...

  14. Origins of eponymous orthopaedic equipment.

    Science.gov (United States)

    Meals, Clifton; Wang, Jeffrey

    2010-06-01

    Orthopaedists make great use of eponymous equipment, however the origins of these tools are unknown to many users. This history enriches, enlightens, and enhances surgical education, and may inspire modern innovation. We explored the origins of common and eponymous orthopaedic equipment. We selected pieces of equipment named for their inventors and in the broadest use by modern orthopaedists. We do not describe specialized orthopaedic implants and instruments owing to the overwhelming number of these devices. The history of this equipment reflects the coevolution of orthopaedics and battlefield medicine. Additionally, these stories evidence the primacy of elegant design and suggest that innovation is often a process of revision and refinement rather than sudden inspiration. Their history exposes surgical innovators as brilliant, lucky, hardworking, and sometimes odd. These stories amuse, enlighten, and may inspire modern orthopaedists to develop creative solutions of their own. The rich history of the field's eponymous instruments informs an ongoing tradition of innovation in orthopaedics.

  15. Equipment improvements for performance enhancement

    International Nuclear Information System (INIS)

    Gaestel, P.; Guesnon, H.; Sauze, G.

    1994-01-01

    In order to enhance the reactor availability, several improvements on reactor equipment have been developed: design optimization for stator maintenance replacement in the main alternator; adjustment modification of stator coils in the main alternator for an easier maintenance; improvement of the fuel handling line (pole crane, transfer equipment, loading machine); development of a loose part trapping system in the steam generator secondary circuit. 1 tab

  16. Low level photoneutron detection equipment

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Yuqin; Li Yuansui

    1991-01-01

    A low level photoneutron detection equipment has been developed. The photoneutrons produced by interaction of 226 Ra gamma quanta and deutron (D) target are detected with n-n discrimination detector made up of 3 He proportional counter array. The D-content information in the target can be obtained from the measured photoneutron counts. The equipment developed is mainly used for nondestructive D-content measurement of D-devices

  17. FUSRAP equipment concept development study

    International Nuclear Information System (INIS)

    Hinerman, K.B.; Smith, R.E.

    1981-01-01

    Under DOE contract, Dalton-Dalton-Newport, Inc. is performing an engineering evaluation of three selected FUSRAP sites in an effort to generate equipment concepts to perform remedial action for retrieval, packaging, storing, and transporting contaminated soil and other debris. Along with this engineering evaluation, an analysis of state and Federal regulations was made which had significant impact on the selected equipment and costs for each remedial action concept

  18. Remotely operated replaceable process equipment

    International Nuclear Information System (INIS)

    Westendorf, H.

    1987-01-01

    The coupling process of pneumatic and electrical auxiliary lines of a pneumatic control pressure line in a large cell of the reprocessing plant is carried out, together with the coupling process of the connecting flange of the process equipment. The coupling places of the auxiliary lines, such as control or supply lines, are laid in the flange parts of the flanges to be connected. The pipe flange on the frame side remains flush with the connecting flange of the process equipment. (DG) [de

  19. Partners in qualified equipment supply

    International Nuclear Information System (INIS)

    Rygg, D.E.; O'Hare, G.J.

    1993-01-01

    Industry initiatives have been taken to improve procurement practices and commercial dedication programs, formation of procurement engineering groups, emphasis on product quality, and increased engineering involvement in procurement and maintenance of qualified equipment. This poses new challenges for many licensees in terms of resources, product knowledge, and access to information normally held proprietary by equipment suppliers. Alternative approaches to future licensee/Westinghouse relationships which will allow licensees to adapt to the changing environment are discussed. 2 figs

  20. Development of a system for monitoring and diagnosis using Fuzzy logic in control valves of laboratory test equipment of Experimental Center Aramar; Desenvolvimento de um sistema de monitoracao e diagnostico utilizando logica Fuzzy aplicado a valvulas de controle de processo do CEA - Centro Experimental Aramar

    Energy Technology Data Exchange (ETDEWEB)

    Porto Junior, Almir Carlos Soares

    2014-07-01

    The question of components reliability, specifically process control valves, has become an important issue to be investigated in nuclear power plants and other areas such as refinery or offshore oil rig, considering the safety and life extension of the plant. The development of non intrusive monitoring and diagnostic method allows the identification of defects in components of the plant during normal operation. The objective of this dissertation is to present an analysis and diagnosis of control valves of a steam plant part that simulates the secondary circuit of a pressurized water reactor. This installation is part of propulsion equipment testing laboratory of the Brazilian Navy, at Ipero-SP. The methodology for design is based on graphical analysis of two parameters, the valve air pressure actuator and the displacement of the valve plug. These data are extracted by a smart positioner, part of Delta V™ Automation System. An analysis is implemented in detecting anomalies by an approach using Expert Systems by the technique of fuzzy logic. Once the basic measures of control valves are taken, it is possible to detect symptoms of failure, leakage, friction, damage, etc. The monitoring and diagnostic system has been designed in MATLAB® version 2009{sup th} by the complement 'Fuzzy Logic Toolbox'. It is a noninvasive technique. Thus, it is possible to know what is happening with the chosen components, just analyzing the parameters of the valve. The software called ValveLink® (developed by Emerson) receives signals from hardware component (intelligent positioner) installed next to the control valve. These signals (electrical current) are transformed into information which are used input parameters: air pressure valve actuator and valve plug displacement. With the use of fuzzy logic, these parameters are interpreted. They suffer inferences by rules written by experts in valves. After these inferences, the information is processed and sent as output signals

  1. The improvement of maintenance service for traction networks equipment on the base of process approach

    Directory of Open Access Journals (Sweden)

    D. V. Mironov

    2014-12-01

    Full Text Available Purpose. The new methods development for improving the maintenance service for equipment of traction networks in order to increase its efficiency and quality. Methodology. In world practice of solving problems related to the quality of products and services is usually achieved by introducing quality management system in to the enterprises. The provisions of quality management system were used for solving the problem. The technologies of process engineering were used for describing the main stages of maintenance service. Findings. The development of high-speed movement and growth of its intensity, the use of electric rolling stock of a new generation require the introduction of new methods diagnostics of equipment technical state and improvement of the existing maintenance system and repair of power supply. Developing a model of business-processes, their optimization with using techniques of process engineering and system management is needed for the transition to the management system based on the process approach. From the standpoint of the process approach and in accordance with the requirements of the quality management system (ISO 9001-2009, the operation of the E (Department of electrification and power supply infrastructure sector is represented as a scheme of business-processes in which the guaranteed supply with electricity of railway and third-party consumers is defined as the main business-process of management. Each of the sub-process of power supply for consumers is described in details. The use methods and main stages of process approach for sample management system reorganization were investigated. The methodology and the application method of PDCA (Plan-Do-Check-Act closed loop to the equipment maintenance system were described. The monitoring process of traction networks maintenance using the process approach was divided into components after investigations. The technical documentation of maintenance service was investigated in

  2. Closing the loop.

    Science.gov (United States)

    Dassau, E; Atlas, E; Phillip, M

    2010-02-01

    The dream of closing the loop is actually the dream of creating an artificial pancreas and freeing the patients from being involved with the care of their own diabetes. Insulin-dependent diabetes (type 1) is a chronic incurable disease which requires constant therapy without the possibility of any 'holidays' or insulin-free days. It means that patients have to inject insulin every day of their life, several times per day, and in order to do it safely they also have to measure their blood glucose levels several times per day. Patients need to plan their meals, their physical activities and their insulin regime - there is only very small room for spontaneous activities. This is why the desire for an artificial pancreas is so strong despite the fact that it will not cure the diabetic patients. Attempts to develop a closed-loop system started in the 1960s but never got to a clinical practical stage of development. In recent years the availability of continuous glucose sensors revived those efforts and stimulated the clinician and researchers to believe that closing the loop might be possible nowadays. Many papers have been published over the years describing several different ideas on how to close the loop. Most of the suggested systems have a sensing arm that measures the blood glucose repeatedly or continuously, an insulin delivery arm that injects insulin upon command and a computer that makes the decisions of when and how much insulin to deliver. The differences between the various published systems in the literature are mainly in their control algorithms. However, there are also differences related to the method and site of glucose measurement and insulin delivery. SC glucose measurements and insulin delivery are the most studied option but other combinations of insulin measurements and glucose delivery including intravascular and intraperitoneal (IP) are explored. We tried to select recent publications that we believe had influenced and inspired people interested

  3. Selection of Corrosion Monitoring Equipment for Subsea Safety Joint

    OpenAIRE

    Ramachandran, Sajini

    2016-01-01

    Master Thesis in Offshore technology: Industrial asset management In Nature, most of all Metals evolve as stable ores of chemical compounds like oxides, sulphides or carbonates. Lot of energy is required to refine and make them useful for some means for every Industry. Corrosion on metals can reverse an unnatural process back to a lower state of energy, easily as simple. It eats away metal in outdoor furniture and automotive bodies, leaving the surface with bad appearance and if it is n...

  4. Sea-Ice Thickness Monitoring from Sensor Equipped Inuit Sleds

    Science.gov (United States)

    Rodwell, Shane; Jones, Bryn; Wilkinson, Jeremy

    2013-04-01

    A novel instrumentation package capable of measuring sea-ice thickness autonomously has been designed for long-term deployment upon the dog drawn sleds of the indigenous peoples of the Arctic. The device features a range of sensors that have been integrated with an electromagnetic induction device. These include a global positioning system, temperature sensor, tilt meter and accelerometer. Taken together, this system is able to provide accurate (+/-5cm) measurements of ice thickness with spatio-temporal resolution ranging from 1m to 5m every second. Autonomous data transmission capability is provided via GSM, inspired by the fact that many of the coastal communities in Greenland possess modern cell-phone infrastructure, enabling an inexpensive means of data-retrieval. Such data is essential in quantifying the sea-ice mass balance; given that existing satellite based systems are unable to measure ice-thickness directly. Field-campaign results from a prototype device, deployed in the North West of Greenland during three consecutive seasons, have demonstrated successful proof-of-concept when compared to data provided by ice mass balance (IMB) stations provided at fixed positions along the route of the sled. This project highlights not only the use of novel polar technology, but how opportunistic deployment using an existing roving platform (Inuit sledges) can provide economical, yet highly valuable, data for instrumentation development.

  5. Monitoring gamma radioactivity over large land areas using portable equipment

    International Nuclear Information System (INIS)

    Mac Mahon, T.D.; Gray, P.W.; Eer, A.M. D'; Naboulsi, A.H.; Koutsoyannopoulos, C.

    1990-01-01

    The principal objective of this research has been to provide information on cost-effective techniques to detect localized areas of gamma-emitting radionuclides. This objective has been achieved by determining the time required to scan unit area as a function of depth of the gamma source below the site surface, the activity of the gamma source, the energy of the emitted gamma-ray, and the gamma transport properties of the site material. A comparison between survey and sampling techniques is made, and the advantages of using survey techniques to detect localized gamma-ray sources are discussed. A survey technique based on an adaptive moving array detector system is described. A field experiment has been carried out to verify the results of calculations of the sensitivity of the techniques described

  6. 40 CFR 60.256 - Continuous monitoring requirements.

    Science.gov (United States)

    2010-07-01

    ... facilities that use wet scrubber emission control equipment: (A) A monitoring device for the continuous measurement of the pressure loss through the venturi constriction of the control equipment. The monitoring... paragraph (c) of this section. (2) For mechanical vents with wet scrubbers, monitoring devices according to...

  7. Design of Remote Monitoring System of Irrigation based on GSM and ZigBee Technology

    Science.gov (United States)

    Xiao xi, Zheng; Fang, Zhao; Shuaifei, Shao

    2018-03-01

    To solve the problems of low level of irrigation and waste of water resources, a remote monitoring system for farmland irrigation based on GSM communication technology and ZigBee technology was designed. The system is composed of sensors, GSM communication module, ZigBee module, host computer, valve and so on. The system detects and closes the pump and the electromagnetic valve according to the need of the system, and transmits the monitoring information to the host computer or the user’s Mobile phone through the GSM communication network. Experiments show that the system has low power consumption, friendly man-machine interface, convenient and simple. It can monitor agricultural environment remotely and control related irrigation equipment at any time and place, and can better meet the needs of remote monitoring of farmland irrigation.

  8. Cryogenic Beam Loss Monitoring for the LHC

    CERN Document Server

    Kurfuerst, C; Sapinski, M

    A Beam Loss Monitoring (BLM) system was installed on the outside surface of the LHC magnet cryostats to protect the accelerator equipment from beam losses. The protection is achieved by extracting the beam from the ring in case thresholds imposed on measured radiation levels are exceeded. Close to the interaction regions of the LHC, the present BLM system is sensitive to particle showers generated in the interaction region of the two beams. In the future, with beams of higher energy and brightness resulting in higher luminosity, distinguishing between these interaction products and possible quench-provoking beam losses from the primary proton beams will be challenging. The particle showers measured by the present BLM configuration are partly shielded by the cryostat and the iron yoke of the magnets. The system can hence be optimised by locating beam loss monitors as close as possible to the protected element, i. e. the superconducting coils, inside the cold mass of the magnets in superfluid helium at 1.9 K. T...

  9. 29 CFR 97.32 - Equipment.

    Science.gov (United States)

    2010-07-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  10. 44 CFR 13.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  11. 24 CFR 85.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  12. 41 CFR 105-71.132 - Equipment.

    Science.gov (United States)

    2010-07-01

    .... (4) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be... managing equipment (including replacement equipment), whether acquired in whole or in part with grant funds... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Equipment. 105-71.132...

  13. 43 CFR 12.72 - Equipment.

    Science.gov (United States)

    2010-10-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  14. 1968 Listing of Swimming Pool Equipment.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI. Testing Lab.

    An up-to-date listing of swimming pool equipment including--(1) companies authorized to display the National Sanitation Foundation seal of approval, (2) equipment listed as meeting NSF swimming pool equipment standards relating to diatomite type filters, (3) equipment listed as meeting NSF swimming pool equipment standard relating to sand type…

  15. Trilateral Initiative: IAEA authentication and national certification of verification equipment for facilities with classified forms of fissile material

    International Nuclear Information System (INIS)

    Haas, Eckard; Sukhanov, Alexander; Murphy, John

    2001-01-01

    Full text: Within the framework of the Trilateral Initiative, technical challenges have arisen due to the potential of the International Atomic Energy Agency (IAEA) monitoring fissile material with classified characteristics, as well as the IAEA using facility or host country supplied monitoring equipment. In monitoring material with classified characteristics, it is recognized that the host country needs to assure that classified information is not made available to the IAEA inspectors. Thus, any monitoring equipment used to monitor material with classified characteristics has to contain information security capabilities, such as information barriers. But likewise in using host-country-supplied monitoring equipment, regarding the material being monitored the IAEA has to have confidence that the information provided by the equipment is genuine and can be used by the IAEA in fulfilling its obligation to derive conclusions based on independent verification measures. Thus the IAEA needs to go through the process of authenticating the monitoring equipment. In the same way the host country needs to go through the process to assure itself that the monitoring equipment integrated with an information barrier will not divulge any classified information about an inspected sensitive item. Both processes require on large extent identical measures, but partially also may conflict with each other. The fact that monitoring equipment needs to exhibit information security throughout its lifecycle while at the same time be capable of being authenticated necessitates the need for creative technical approaches to be pursued. (author)

  16. Stratospheric Platforms for Monitoring Purposes

    International Nuclear Information System (INIS)

    Konigorski, D.; Gratzel, U.; Obersteiner, M.; Schneidereit, M.

    2010-01-01

    Stratospheric platforms are emerging systems based on challenging technology. Goal is to create a platform, payload, and mission design which is able to complement satellite services on a local scale. Applications are close to traditional satellite business in telecommunication, navigation, science, and earth observation and include for example mobile telecommunications, navigation augmentation, atmospheric research, or border control. Stratospheric platforms could potentially support monitoring activities related to safeguards, e.g. by imagery of surfaces, operational conditions of nuclear facilities, and search for undeclared nuclear activities. Stratospheric platforms are intended to be flown in an altitude band between 16 and 30 km, above 16-20 km to take advantage of usually lower winds facilitating station keeping, below 30 km to limit the challenges to achieve a reasonable payload at acceptable platform sizes. Stratospheric platforms could substitute satellites which are expensive and lack upgrade capabilities for new equipment. Furthermore they have practically an unlimited time over an area of interest. It is intended to keep the platforms operational and maintenance free on a 24/7 basis with an average deployment time of 3 years. Geostationary satellites lack resolution. Potential customers like Armed Forces, National Agencies and commercial customers have indicated interest in the use of stratospheric platforms. Governmental entities are looking for cheaper alternatives to communications and surveillance satellites and stratospheric platforms could offer the following potential advantages: Lower operational cost than satellite or UAV (Unmanned Aerial Vehicles) constellation (fleet required); Faster deployment than satellite constellation; Repositioning capability and ability to loiter as required; Persistent long-term real-time services over a fairly large regional spot; Surge capability: Able to extend capability (either monitoring or communications

  17. Monitoring every last trace

    CERN Multimedia

    CERN Bulletin

    2014-01-01

    The LHC is set to reach a record energy of 6.5 TeV per beam next year and will therefore be producing high energy radiation, as will the injectors supplying it. When exposed to this radiation, some equipment could potentially become radioactive and must therefore be carefully identified and monitored... this is where TREC comes in: software developed by CERN and currently being deployed in our accelerators.   If it becomes slightly radioactive, some of the equipment that makes up CERN’s accelerators may potentially become a hazard to the people who handle or work near it. Even though the risk is usually very low, CERN is obliged to record the location of this equipment, identify it and deal with it in an appropriate manner. During LS1 for example, almost 30,000 radiation protection checks were carried out on more than 2,500 tonnes of equipment! In 2009, going one step further in monitoring this equipment and making the Laboratory even safer, Luca Bruno, then the Radiation Safety Of...

  18. The role of lubricant analysis in maximizing lubricant and equipment life

    International Nuclear Information System (INIS)

    Janis, J.

    1995-01-01

    Lubricant analysis has always played an important yet somewhat invisible role in equipment health monitoring. At its most primitive, simple observations and field testing alert equipment operators to changing conditions. At its most advanced, data from performance and analytical tests are used to develop or select optimum lubricants for service, stretch drain intervals, predict remaining equipment life and identify potential equipment or system problems at an incipient stage. Coupled with thermography and vibration analysis, lubricant analysis can become a major component of a comprehensive predictive maintenance (PM) program. Ontario Hydro finds itself at a turning point regarding the use and monitoring of lubricants. Increasing emphasis on equipment reliability and plant life extension, coupled with major, recent changes in lubricant composition in response to environmental, energy and safety concerns, forces an upgrading of many aspects of lubricant monitoring so that it may establish itself as a key part of modern PM practices. This paper discusses some of these aspects. (author)

  19. Verifiable process monitoring through enhanced data authentication

    International Nuclear Information System (INIS)

    Goncalves, Joao G.M.; Schwalbach, Peter; Schoeneman, Barry Dale; Ross, Troy D.; Baldwin, George Thomas

    2010-01-01

    To ensure the peaceful intent for production and processing of nuclear fuel, verifiable process monitoring of the fuel production cycle is required. As part of a U.S. Department of Energy (DOE)-EURATOM collaboration in the field of international nuclear safeguards, the DOE Sandia National Laboratories (SNL), the European Commission Joint Research Centre (JRC) and Directorate General-Energy (DG-ENER) developed and demonstrated a new concept in process monitoring, enabling the use of operator process information by branching a second, authenticated data stream to the Safeguards inspectorate. This information would be complementary to independent safeguards data, improving the understanding of the plant's operation. The concept is called the Enhanced Data Authentication System (EDAS). EDAS transparently captures, authenticates, and encrypts communication data that is transmitted between operator control computers and connected analytical equipment utilized in nuclear processes controls. The intent is to capture information as close to the sensor point as possible to assure the highest possible confidence in the branched data. Data must be collected transparently by the EDAS: Operator processes should not be altered or disrupted by the insertion of the EDAS as a monitoring system for safeguards. EDAS employs public key authentication providing 'jointly verifiable' data and private key encryption for confidentiality. Timestamps and data source are also added to the collected data for analysis. The core of the system hardware is in a security enclosure with both active and passive tamper indication. Further, the system has the ability to monitor seals or other security devices in close proximity. This paper will discuss the EDAS concept, recent technical developments, intended application philosophy and the planned future progression of this system.

  20. Underground coal mining - methods, equipment developments and trends

    Energy Technology Data Exchange (ETDEWEB)

    Singhal, R

    1988-12-01

    Underground mines are truly beginning to accept the so-called 'high tech' technology evident in other industries. Automation, remote control and robotics have taken an added significance. Wireless communication, mine-wide equipment health and performance monitoring, and transmission of data from deeper levels to surface is moving towards becoming the norm. There is emphasis on developing and applying continuous mining systems, as well as on modifying cyclical discontinuous methods to continuous systems. Multi-purpose equipment is also being developed. Technology transfer is playing its role - equipment and systems from surface coal mining are being applied to underground mining and vice-versa. At the American Mining Congress Exhibition held in Chicago in April 1988, a variety of equipment for underground mining was displayed including coal face equipment such as shearer loaders, conveyors and powered supports, and equipment for room-and-pillar coal mining. The trend continues to be towards high power machines equipped with a variety of electronics and sensors, safety devices, and alarm systems. Ancillary equipment on display covered a variety of cutting drums, cutting tools, conveying equipment and so on. In room-and-pillar mining, the overall emphasis was on moving away from the cyclical nature of the work. Transportation by shuttle cars must be replaced by continuous transport systems such as conveyors. Experience from Australia has shown that the application of continuous haulage and breaker line supports has permitted a doubling of production from room-and-pillar systems. Production levels of 3,000tpd have already been achieved, and 4,000tpd is considered achievable.

  1. Equipment for capping drums, especially with radioactive waste

    International Nuclear Information System (INIS)

    Bednarik, F.

    1987-01-01

    The equipment consists of a pneumatic cylinder, lever systems with jaws, guide bars, and of securing pins. The top cylinder lid and the bottom cylinder lid provided with openings are slidably attached to a shaft firmly connected to a piston and a support plate. Firmly attached to the bottom lid using brackets are pins holding connecting rods controlling the double-arm levers pivoted on pins, featuring jaws pivoted on forks firmly attached to the support plate and provided with a replaceable spacer insert. The guide bars are firmly attached to the support plate via braces and stiffeners. The securing pins are loaded with springs seated in the braces. The benefits of the equipment include that the lid closing levers with jaws, mechanically controlled using one pneumatic cylinder, thanks to their number and configuration, close the lid around the drum border provided with small recesses which do not reach above the circumference of the drum being closed. The equipment can also be used for carrying closed drums, this also during compressed air failures because the levers with jaws are secured in position with the pneumatic cylinder leg. (J.B.). 1 fig

  2. Video equipment of tele dosimetry and audio

    International Nuclear Information System (INIS)

    Ojeda R, M.A.; Padilla C, I.

    2007-01-01

    To develop a work in an area with high radiation, it requires of a detailed knowledge of the surroundings work, a communication and effective vision, a near dosimetric control. In a work where the spaces variables and reduced accesses exist, noise that hinders the communication, defendant operative condition, radiation field and taking of decision, it is necessary to have tools that allow a total control of the environment to make opportune and effective decisions, there where the task is developed. Under this elementary concept, it was developed in the Laguna Verde Central a project that it allowed a mechanism, interactive of control in spaces complex; to see, to hear, to speak, to measure. This concept takes to the creation of an equipped system with closed circuit of television, wireless communication systems, tele dosimetry wireless systems, VHS and DVD recording equipment, uninterrupted energy units. The system requires of an electric power socket, and the installation of two cables by CCTV camera. The system is mobilized by a person. He puts on in operation in 5 minutes using a verification list. The concept was developed in the project denominated VETA-1, (Video Equipment of Tele dosimetry and Audio). It is objective of this work to present before the society the development of the VETA-1 tool that conclude in their first prototype in May of the present year. The VETA-1 project arises by a necessity of optimizing dose, it is an ALARA tool, with a countless applications, like it was proven in the 12 recharge stop of the Unit 1. The VETA-1 project integrate a recording system, with the primary end of analyzing in the place where the task is developed the details for an effective and opportune decision, but the resulting information is of utility for the personnel's training and the planning of future works. The VETA-1 system is an ALARA tool of quick response control. (Author)

  3. AVM branch vibration test equipment

    International Nuclear Information System (INIS)

    Anne, J.P.

    1995-01-01

    An inventory of the test equipment of the AVM Branch ''Acoustic and Vibratory Mechanics Analysis Methods'' group has been undertaken. The purpose of this inventory is to enable better acquaintance with the technical characteristics of the equipment, providing an accurate definition of their functionalities, ad to inform potential users of the possibilities and equipment available in this field. The report first summarizes the various experimental surveys conduced. Then, using the AVM equipment database to draw up an exhaustive list of available equipment, it provides a full-scope picture of the vibration measurement systems (sensors, conditioners and exciters) and data processing resources commonly used on industrial sites and in laboratories. A definition is also given of a mobile test unit, called 'shelter', and a test bench used for the testing and performance rating of the experimental analysis methods developed by the group. The report concludes with a description of two fixed installations: - the calibration bench ensuring the requisite quality level for the vibration measurement systems ; - the training bench, whereby know-how acquired in the field in the field of measurement and experimental analysis processes is made available to others. (author). 27 refs., 15 figs., 2 appends

  4. Closing the fuel cycle

    International Nuclear Information System (INIS)

    Wolfe, B.; Judson, B.F.

    1984-01-01

    The possibilities for closing the fuel cycle in today's nuclear climate in the US are compared with those envisioned in 1977. Reprocessing, the fast breeder reactor program, and the uranium supply are discussed. The conclusion drawn is that the nuclear world is less healthy and less stable than the one previously envisioned and that the major task before the international nuclear community is to develop technologies, institutions, and accepted procedures that will allow to economically provide the huge store of energy from reprocessing and the breeder that it appears the world will desperately need

  5. Closing the gaps to eliminate mothertochild transmission of HIV MTCT in South Africa: Understanding MTCT case rates factors that hinder the monitoring and attainment of targets and potential game changers

    Directory of Open Access Journals (Sweden)

    U Feucht

    2018-03-01

    Full Text Available Background. Ninety percent of the world’s HIV-positive pregnant women live in 22 countries. These 22 countries, including South Africa (SA have prioritised the elimination of mother-to-child transmission of HIV (EMTCT. Since 2016 all 22 countries recommend lifelong antiretroviral treatment for all HIV-positive pregnant and lactating women. To measure South African national, provincial and district-level progress towards attaining EMTCT, we analysed the number of in utero (IU paedatric HIV infections per 100 000 live births (IU case rate, and synthesised factors hindering the monitoring of EMTCT progress and attainment from the viewpoint of provincial and district-level healthcare managers and implementers. We highlight potential innovations to strengthen health systems and improve EMTCT programme delivery. Methods. We reviewed national-, provincial- and district-level birth HIV testing data from routine National Health Laboratory Services (NHLS records between April 2016 and March 2017. To obtain a qualitative perspective from healthcare managers and implementers, we synthesised information from the nine 2016 provincial-level EMTCT stock-taking workshops. These workshops involve key provincial and district-level staff, mentors and supporting partners. Lastly, we highlight potential innovations presented at these workshops to overcome operational challenges. Results. The national IU mother-to-child transmission (MTCT rate was 0.9%, which translated to an IU case rate of 245 HIV-positive neonates per 100 000 live births. Provincial IU percent MTCT risk ranged from 0.6% to 1.3%, with IU case rates ranging between 168 and 325 cases per 100 000 live births. District-level IU percent MTCT risk ranged from 0.4% to 1.9%. Potential game changers include: pre-conception counselling to optimise maternal-partner health, weekly dissemination of HIV polymerase chain reaction (PCR and viral load reports from the NHLS to specific individuals who

  6. 78 FR 25916 - Authorization of Radiofrequency Equipment

    Science.gov (United States)

    2013-05-03

    ...] Authorization of Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Proposed rule... bodies, and measurement procedures used to determine RF equipment compliance. The Commission believes... Commission is responsible for an equipment authorization program for radiofrequency (RF) devices under part 2...

  7. Bilateral tension pneumothorax following equipment improvisation.

    Science.gov (United States)

    Zambricki, Christine; Schmidt, Carol; Vos, Karen

    2014-02-01

    This case report describes an unexpected event that took place as a result of using improvised equipment. The patient, a 16-year-old female undergoing complex oral surgery, suffered bilateral pneumothorax following the improper use of an airway support device. During the immediate postoperative period with the patient still intubated, oxygen tubing was attached to a right angle elbow connector with the port closed and 10 L/minute oxygen flow was administered to the patient in a manner that did not allow the patient to exhale. Within seconds, pneumothorax was apparent as the patient's vital signs deteriorated, visible swelling was noted in the shoulders and neck, and there was an absence of breath sounds on auscultation. This case study has application beyond the immediate discussion of bilateral pneumothorax, serving as a caution about the unintended consequences of equipment improvisation. In addition to highlighting the hazards of providing patient care with a non-standard device, this study also provides a powerful example of the human factors that can contribute to medical errors in the healthcare setting.

  8. Code of Practice for Protection Against Ionizing Radiation Emitted from X-ray Analysis Equipment (1984)

    International Nuclear Information System (INIS)

    1984-01-01

    Appropriate working rules, safety features and monitoring requirements for general X-ray analysis units or equipment are laid down in this Code which is intended for users of such equipment. The Code advises that establishments draw up their own working procedures based on appropriate legislation and on the recommendations contained in this Code. The Code also describes the requirements for X-ray analysis equipment necessary to ensure safety. (NEA) [fr

  9. After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-load Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Margaret J.; Busch, John F.

    2004-01-22

    This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of ''miscellaneous'' plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from twelve commercial buildings in California, Georgia, and Pennsylvania: two health care buildings, two large offices (> 500 employees each), three medium offices (50-500 employees), four education buildings, and one ''small office'' that is actually an aggregate of five small businesses. Two buildings are in the San Francisco Bay area of California, five are in

  10. IMPROVED WELL PLUGGING EQUIPMENT AND WASTE MANGEMENT TECHNIQUES EXCEED ALARA GOALS AT THE OAK RIDGE NATIONAL LABORATORY

    International Nuclear Information System (INIS)

    Whiteside, R.; Pawlowicz, R.; Whitehead, L.; Arnseth, R.

    2002-01-01

    In 2000, Bechtel Jacobs Company LLC (BJC) contracted Tetra Tech NUS, Inc. (TtNUS) and their sub-contractor, Texas World Operations, Inc. (TWO), to plug and abandon (P and A) 111 wells located in the Melton Valley area of Oak Ridge National Laboratory (ORNL). One hundred and seven of those wells were used to monitor fluid movement and subsurface containment of the low level radioactive liquid waste/grout slurry that was injected into the Pumpkin Valley Shale Formation, underlying ORNL. Four wells were used as hydrofracture injection wells to emplace the waste in the shale formation. Although the practice of hydrofracturing was and is considered by many to pose no threat to human health or the environment, the practice was halted in 1982 after the Federal Underground Injection Control regulations were enacted by United States Environmental Protection Agency (USEPA) making it necessary to properly close the wells. The work is being performed for the United States Department of Energy Oak Ridge Operations (DOE ORO). The project team is using the philosophy of minimum waste generation and the principles of ALARA (As Low As Reasonably Achievable) as key project goals to minimize personnel and equipment exposure, waste generation, and project costs. Achievement of these goals was demonstrated by the introduction of several new pieces of custom designed well plugging and abandonment equipment that were tested and used effectively during field operations. Highlights of the work performed and the equipment used are presented

  11. Production planning and control of closed-loop supply chains

    NARCIS (Netherlands)

    K. Inderfurth (Karl); R.H. Teunter (Ruud)

    2001-01-01

    textabstractMore and more supply chains emerge that include a return flow of materials. Many original equipment manufacturers are nowadays engaged in the remanufacturing business. In many process industries, production defectives and by-products are reworked. These closed-loop supply chains deserve

  12. Closed Strings From Nothing

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, Albion

    2001-07-25

    We study the physics of open strings in bosonic and type II string theories in the presence of unstable D-branes. When the potential energy of the open string tachyon is at its minimum, Sen has argued that only closed strings remain in the perturbative spectrum. We explore the scenario of Yi and of Bergman, Hori and Yi, who argue that the open string degrees of freedom are strongly coupled and disappear through confinement. We discuss arguments using open string field theory and worldsheet boundary RG flows, which seem to indicate otherwise. We then describe a solitonic excitation of the open string tachyon and gauge field with the charge and tension of a fundamental closed string. This requires a double scaling limit where the tachyon is taken to its minimal value and the electric field is taken to its maximum value. The resulting flux tube has an unconstrained spatial profile; and for large fundamental string charge, it appears to have light, weakly coupled open strings living in the core. We argue that the flux tube acquires a size or order {alpha}' through sigma model and string coupling effects; and we argue that confinement effects make the light degrees of freedom heavy and strongly interacting.

  13. Closed Strings From Nothing

    International Nuclear Information System (INIS)

    Lawrence, Albion

    2001-01-01

    We study the physics of open strings in bosonic and type II string theories in the presence of unstable D-branes. When the potential energy of the open string tachyon is at its minimum, Sen has argued that only closed strings remain in the perturbative spectrum. We explore the scenario of Yi and of Bergman, Hori and Yi, who argue that the open string degrees of freedom are strongly coupled and disappear through confinement. We discuss arguments using open string field theory and worldsheet boundary RG flows, which seem to indicate otherwise. We then describe a solitonic excitation of the open string tachyon and gauge field with the charge and tension of a fundamental closed string. This requires a double scaling limit where the tachyon is taken to its minimal value and the electric field is taken to its maximum value. The resulting flux tube has an unconstrained spatial profile; and for large fundamental string charge, it appears to have light, weakly coupled open strings living in the core. We argue that the flux tube acquires a size or order α' through sigma model and string coupling effects; and we argue that confinement effects make the light degrees of freedom heavy and strongly interacting

  14. Another donation of computer equipment

    CERN Multimedia

    Anaïs Schaeffer

    2014-01-01

    On Thursday 27 February, CERN was pleased to donate computer equipment to a physics institute in the Philippines.   H.E. Leslie J. Baja and Rolf Heuer. Following donations of computer equipment to institutes in Morocco, Ghana, Bulgaria, Serbia and Egypt, CERN is to send 50 servers and 4 network switches to the National Institute of Physics at the University of the Philippines Diliman. CERN’s Director-General Rolf Heuer and the Ambassador of the Philippines to Switzerland and Lichtenstein, H.E. Leslie J. Baja, spoke of their enthusiasm for the project during an official ceremony. The equipment will be used for various high energy physics research programmes in the Philippines and for the University’s development of digital resources for science.

  15. LDRD report: Smoke effects on electrical equipment

    International Nuclear Information System (INIS)

    TANAKA, TINA J.; BAYNES, EDWARD E. JR.; NOWLEN, STEVEN P.; BROCKMANN, JOHN E.; GRITZO, LOUIS A.; SHADDIX, Christopher R.

    2000-01-01

    Smoke is known to cause electrical equipment failure, but the likelihood of immediate failure during a fire is unknown. Traditional failure assessment techniques measure the density of ionic contaminants deposited on surfaces to determine the need for cleaning or replacement of electronic equipment exposed to smoke. Such techniques focus on long-term effects, such as corrosion, but do not address the immediate effects of the fire. This document reports the results of tests on the immediate effects of smoke on electronic equipment. Various circuits and components were exposed to smoke from different fields in a static smoke exposure chamber and were monitored throughout the exposure. Electrically, the loss of insulation resistance was the most important change caused by smoke. For direct current circuits, soot collected on high-voltage surfaces sometimes formed semi-conductive soot bridges that shorted the circuit. For high voltage alternating current circuits, the smoke also tended to increase the likelihood of arcing, but did not accumulate on the surfaces. Static random access memory chips failed for high levels of smoke, but hard disk drives did not. High humidity increased the conductive properties of the smoke. The conductivity does not increase linearly with smoke density as first proposed; however, it does increase with quantity. The data can be used to give a rough estimate of the amount of smoke that will cause failures in CMOS memory chips, dc and ac circuits. Comparisons of this data to other fire tests can be made through the optical and mass density measurements of the smoke

  16. CASDAC system: Data Terminal Equipment user's guide

    International Nuclear Information System (INIS)

    Yamamoto, Yoichi; Koyama, Kinji

    1993-03-01

    The CASDAC (Containment And Surveillance Data Authenticated Communication) system has been developed by JAERI for nuclear safeguards and physical protection of nuclear material. This system is a remote monitoring system for continual verification of security and safeguards status of nuclear material. The CASDAC system consists of two subsystems, one of them is a Grand Command Center (GCC) subsystem and the other is a facility subsystem. This report describes the outline and usage of the Data Terminal Equipment (DTE), which makes available of message data communication between the GCC and a facility subsystem. This work has been carried out in the framework of Japan Support Programme for Agency Safeguards (JASPAS) as a project, JA-1. (author)

  17. Research on the organization of equipment of nuclear emergency

    International Nuclear Information System (INIS)

    Li Xiaoming; Yang Jun

    2012-01-01

    The emergency rescue operation on major accident of nuclear facilities contains four kinds of abilities that are command and control, radiation protection, radiation monitoring and radioactive decontamination, so it needs to organize some equipment of nuclear emergency to enhance the efficiency of nuclear emergency operation. The organization of equipment of nuclear emergency should accord to the reality of the development in our country. It should have extractive structure, brief variety and advance capability, and also should be convenient, useful and adequate. The method of organization can first accord to the organization of group and organize the facilities accord to the organization of group of the emergency rescue force. (authors)

  18. Biofilms associated with poultry processing equipment.

    Science.gov (United States)

    Lindsay, D; Geornaras, I; von Holy, A

    1996-01-01

    Aerobic and Gram-negative bacteria were enumerated on non-metallic surfaces and stainless steel test pieces attached to equipment surfaces by swabbing and a mechanical dislodging procedure, respectively, in a South African grade B poultry processing plant. Changes in bacterial numbers were also monitored over time on metal test pieces. The highest bacterial counts were obtained from non-metallic surfaces such as rubber fingered pluckers and plastic defeathering curtains which exceeded the highest counts found on the metal surfaces by at least 1 log CFU cm-2. Gram-negative bacterial counts on all non-metallic surface types were at least 2 log CFU cm-2 lower than corresponding aerobic plate counts. On metal surfaces, the highest microbial numbers were obtained after 14 days exposure, with aerobic plate counts ranging from 3.57 log CFU cm-2 to 5.13 log CFU cm-2, and Gram-negative counts from 0.70 log CFU cm-2 to 3.31 log CFU cm-2. Scanning electron microscopy confirmed the presence of bacterial cells on non-metallic and metallic surfaces associated with poultry processing. Rubber 'fingers', plastic curtains, conveyor belt material and stainless steel test surfaces placed on the scald tank overflow and several chutes revealed extensive and often confluent bacterial biofilms. Extracellular polymeric substances, but few bacterial cells were visible on test pieces placed on evisceration equipment, spinchiller blades and the spinchiller outlet.

  19. Waste Electrical and Electronic Equipment

    DEFF Research Database (Denmark)

    Bigum, Marianne Kristine Kjærgaard; Christensen, Thomas Højlund

    2011-01-01

    Waste electrical and electronic equipment (WEEE) is one of the fastest growing special waste types with an estimated growth of 3–5% per year (Cui and Forssberg, 2003). WEEE is a very heterogeneous waste type that contains many compounds that are considered to be harmful to both humans and the env......Waste electrical and electronic equipment (WEEE) is one of the fastest growing special waste types with an estimated growth of 3–5% per year (Cui and Forssberg, 2003). WEEE is a very heterogeneous waste type that contains many compounds that are considered to be harmful to both humans...

  20. The development of superconducting equipment

    CERN Document Server

    Ueda, T; Hiue, H

    2003-01-01

    Fuji Electric has been developing various types of superconducting equipment for over a quarter of a century. This paper describes the development results achieved for superconducting equipment and especially focuses on large-capacity current leads and superconducting transmission systems, the development of which is being promoted for application to the field of nuclear fusion. High temperature superconductor (HTS) is becoming the mainstream in the field of superconductivity, and the HTS floating coil and conduction-cooled HTS transformed are also introduced as recent developments for devices that utilize this technology. (author)

  1. Mechanical (turbines and auxiliary equipment)

    CERN Document Server

    Sherry, A; Cruddace, AE

    2013-01-01

    Modern Power Station Practice, Volume 3: Mechanical (Turbines and Auxiliary Equipment) focuses on the development of turbines and auxiliary equipment used in power stations in Great Britain. Topics covered include thermodynamics and steam turbine theory; turbine auxiliary systems such as lubrication systems, feed water heating systems, and the condenser and cooling water plants. Miscellaneous station services, and pipework in power plants are also described. This book is comprised of five chapters and begins with an overview of thermodynamics and steam turbine theory, paying particular attenti

  2. QRL closes the circle

    CERN Multimedia

    2006-01-01

    Installation of the cryogenic distribution line (QRL) on sector 1-2, the last to be equipped. Installation began on the last sector of the cryogenic distribution line (QRL) about three weeks ahead of the revised schedule. Besides the recent start on sector 1-2, two other sectors are still being installed. QRL installation is expected to be complete by October. Installation of a single sector involves placing 325 elements and making almost 2000 internal welds. The average time now needed for installing each sector is about four and a half months, compared to the 11 months it took to install the first sector. 'Now people are very well trained and they know they can go fast with a good quality,' said QRL project engineer Germana Riddone. As proof of that quality, QRL technicians can look at the results of the latest pressure test on sector 5-6. There were no internal leaks in the sector and out of 1000 external interconnections there were only three leaks. The QRL project was hampered early on by technical prob...

  3. Safeguards techniques and equipment. 2003 ed

    International Nuclear Information System (INIS)

    2003-01-01

    -destructive analysis (NDA) techniques, and compare their findings with the declared figures and the operator's records. The next level of verification has the aim of detecting whether a fraction of a declared amount is missing (partial defect) and may involve the weighing of items and measurements with NDA techniques such as neutron counting or gamma-ray spectrometry. For detecting bias defects, which would arise if small amounts of material were diverted over a protracted length of time, it is necessary to sample some of the items and to apply physical and chemical analysis techniques having the highest possible accuracy, typically less than one per cent. In order to apply these destructive analysis (DA) techniques, the IAEA requires access to laboratories which use such accurate techniques on a routine basis. Containment and surveillance (C/S) techniques, which are complementary to nuclear material accountancy techniques, are applied in order to maintain continuity of the knowledge gained through IAEA verification, by giving assurance that nuclear material follows predetermined routes, that the integrity of its containment remains unimpaired and that the material is accounted for at the correct measurement points. They also lead to savings in the safeguards inspection effort, e.g. by reducing the frequency of accountancy verification. A variety of C/S techniques are used, primarily optical surveillance and sealing. In remote monitoring, the unattended equipment transmits the data off-site. For unattended and remote monitoring, additional criteria must be met, including high reliability and authentication of the data source. Data communication costs have dropped dramatically in recent years. Data security is an important feature of unattended and remote monitoring systems. Environmental sampling, which allows detection of minute traces of nuclear material, was added to the IAEA's verification measures in the early 1990s as a powerful tool for detecting indications of undeclared

  4. Improved Biomass Cooking Stoves and Improved Stove Emission Equipment

    Energy Technology Data Exchange (ETDEWEB)

    HATFIELD, MICHAEL; Still, Dean

    2013-04-15

    In developing countries, there is an urgent need for access to safe, efficient, and more affordable cooking technologies. Nearly 2.5 billion people currently use an open fire or traditional cookstove to prepare their meals, and recent models predict that use of biomass for cooking will continue to be the dominant energy use in rural, resource-poor households through 2030. For these families, cooking poses serious risks to health, safety, and income. An alarming 4 million people, primarily women and children, die prematurely each year from indoor and outdoor exposure to the harmful emissions released by solid fuel combustion. Use of traditional stoves can also have a significant impact on deforestation and climate change. This dire situation creates a critical need for cookstoves that significantly and verifiably reduce fuel use and emissions in order to reach protective levels for human health and the environment. Additionally, advances in the scientific equipment needed to measure and monitor stove fuel use and emissions have not kept pace with the significant need within the industry. While several testing centers in the developed world may have hundred thousand-dollar emissions testing systems, organizations in the field have had little more than a thermometer, a scale, and subjective observations to quantify the performance of stove designs. There is an urgent need for easy-to-use, inexpensive, accurate, and robust stove testing equipment for use by laboratory and field researchers around the world. ASAT and their research partner, Aprovecho Research Center (ARC), have over thirty years of experience addressing these two needs, improved cookstoves and emissions monitoring equipment, with expertise spanning the full spectrum of development from conceptual design to product manufacturing and dissemination. This includes: 1) research, design, and verification of clean biomass cookstove technology and emissions monitoring equipment; 2) mass production of quality

  5. Science policy up close

    CERN Document Server

    Marburger, John H

    2015-01-01

    In a career that included tenures as president of Stony Brook University, director of Brookhaven National Laboratory, and science advisor to President George W. Bush, John Marburger (1941 2011) found himself on the front line of battles that pulled science ever deeper into the political arena. From nuclear power to global warming and stem cell research, science controversies, he discovered, are never just about science. Science Policy Up Close" presents Marburger s reflections on the challenges science administrators face in the twenty-first century. In each phase of public service Marburger came into contact with a new dimension of science policy. The Shoreham Commission exposed him to the problem of handling a volatile public controversy over nuclear power. The Superconducting Super Collider episode gave him insights into the collision between government requirements and scientists expectations and feelings of entitlement. The Directorship of Brookhaven taught him how to talk to the public about the risks ...

  6. Jealousy and Relationship Closeness

    Directory of Open Access Journals (Sweden)

    Mark Attridge

    2013-02-01

    Full Text Available This study confirmed a hypothesis from the Emotion-in-Relationships conceptual model, which predicts that greater interdependence between relationship partners—or closeness—creates the potential for jealousy. The study also sought to better define the positive side of romantic jealousy in addition to its more negative attributes. College students in premarital relationships (N = 229 completed a questionnaire, including 27 different measures and the Multidimensional Jealousy Scale. Select data were obtained from 122 cases at 3-month follow-up. Each jealousy scale was tested for associations with demographic (age, sex, and race, person (life satisfaction, loneliness, romantic attachment styles, love styles, and romantic beliefs, and relationship (affective, closeness, and social exchange theory constructs. Results clearly distinguished emotional/reactive jealousy as mostly “good” and cognitive/suspicious jealousy as “bad.” Behavioral jealousy was associated with few measures. Implications are discussed for the interdependence model of relationships and the transactional model of jealousy.

  7. Closed metal supports

    Energy Technology Data Exchange (ETDEWEB)

    Dolotov, N P; Afanas' yev, Yu V; Brednev, V A; Nuzhadikhin, A G; Tsiplakov, B V; Uskov, I T

    1980-08-30

    A closed metal support system that has a specific profile includes roof timber, ledger and roof timber. For convenience of transport, assembly, disassembly and repeated use during operation of an extraction powered system, the uprights in the central part are made sectional and are connected to one another by a hinge for folding into transport position. Longitudinal openings are made at the ends of the uprights in order to provide strength by creating flexibility in the hinged connections. The hinged connections of the sectional uprights have elastic gaskets. For convenience in folding the reinforcement, the ends of the uprights of the roof timber and ledger have the shape of a channel at junctions of their hinged connection.

  8. Nonrelativistic closed string theory

    International Nuclear Information System (INIS)

    Gomis, Jaume; Ooguri, Hirosi

    2001-01-01

    We construct a Galilean invariant nongravitational closed string theory whose excitations satisfy a nonrelativistic dispersion relation. This theory can be obtained by taking a consistent low energy limit of any of the conventional string theories, including the heterotic string. We give a finite first order worldsheet Hamiltonian for this theory and show that this string theory has a sensible perturbative expansion, interesting high energy behavior of scattering amplitudes and a Hagedorn transition of the thermal ensemble. The strong coupling duals of the Galilean superstring theories are considered and are shown to be described by an eleven-dimensional Galilean invariant theory of light membrane fluctuations. A new class of Galilean invariant nongravitational theories of light-brane excitations are obtained. We exhibit dual formulations of the strong coupling limits of these Galilean invariant theories and show that they exhibit many of the conventional dualities of M theory in a nonrelativistic setting

  9. Closing the gap

    International Nuclear Information System (INIS)

    Moxon, Suzanne

    1999-01-01

    The problem of fish going through turbines at hydroelectric power plants and the growing concern over the survival rate of salmon at the US Army Corps operated Bonneville lock and dam on the Columbia river in the Pacific Northwest is discussed. The protection of the fish, the assessment of the hazards facing fish passing through turbines, the development of a new turbine, and improved turbine efficiency that reduces cavitation, turbulence and shear flow are examined. The closing of the gap between the turbine blades, hub and discharge ring to increase efficiency and reduce the risk to fish, and the development of the minimum gap runner (MGR) are described, and the lower maximum permitted power output of MGR is noted. (UK)

  10. Development of an equipment diagnostic system that evaluates sensor drift

    International Nuclear Information System (INIS)

    Kanada, Masaki; Arita, Setsuo; Tada, Nobuo; Yokota, Katsuo

    2011-01-01

    The importance of condition monitoring technology for equipment has increased with the introduction of condition-based maintenance in nuclear power plants. We are developing a diagnostic system using process signals for plant equipment, such as pumps and motors. It is important to enable the diagnostic system to distinguish sensor drift and equipment failure. We have developed a sensor drift diagnostic method that combines some highly correlative sensor signals by using the MT (Mahalanobis-Taguchi) method. Furthermore, we have developed an equipment failure diagnostic method that measures the Mahalanobis distance from the normal state of equipment by the MT method. These methods can respectively detect sensor drift and equipment failure, but there are the following problems. In the sensor drift diagnosis, there is a possibility of misjudging the sensor drift when the equipment failure occurs and the process signal changes because the behavior of the process signal is the same as that of the sensor drift. Oppositely, in the equipment failure diagnosis, there is a possibility of misjudging the equipment failure when the sensor drift occurs because the sensor drift influences the change of process signal. To solve these problems, we propose a diagnostic method combining the sensor drift diagnosis and the equipment failure diagnosis by the MT method. Firstly, the sensor drift values are estimated by the sensor drift diagnosis, and the sensor drift is removed from the process signal. It is necessary to judge the validity of the estimated sensor drift values before removing the sensor drift from the process signal. We developed a method for judging the validity of the estimated sensor drift values by using the drift distribution based on the sensor calibration data. And then, the equipment failure is diagnosed by using the process signals after removal of the sensor drifts. To verify the developed diagnostic system, several sets of simulation data based on abnormal cases

  11. Methodology development for availability improvement of standby equipment

    International Nuclear Information System (INIS)

    Shin, Sung Min; Jeon, In Seop; Kang, Hyun Gook

    2014-01-01

    The core damage frequency (CDF) of operating and constructing pressurized nuclear plants are ranging on the order of 10 -5 and 10 -6 per year. The target CDF of new NPP design has been set at 10 -7 . In this context, although various systems are currently studied, availability improvement of standby equipment will be more efficient than the additional application of safety systems. It is obvious in every aspect, such as management and cost efficiency. Here, soundness can affect equipment unavailability, and the soundness degrades because of aging. However, some studies did not consider aging when calculating the unavailability. Standby equipment can age because of two important factors: standby stress which accumulates over time, and test stress which accumulates with the number of tests (or operations). Both factors should be considered together when aging is considered. However, some studies only considered standby stress or test stress. There are some previous studies which considered both factors. Besides equipment soundness related to aging effect, some process like bypass during test also can affect equipment unavailability because the original function of equipment cannot be performed immediately during this process. However, there are seldom studies dealing with above factors as a whole problem. This study investigated a general approach to calculate the unavailability of standby equipment which considers aging caused by standby and test stresses and bypass process. Based on this general approach, we propose two maintenance strategies which aim to reduce standby equipment unavailability. In section 2, the general approach is presented. As one of the strategies, the changing test interval method (CIM) is introduced in section 3, and its effectiveness is also analyzed. The online monitoring method (OMM) is investigated in section 4 as another method to reduce equipment unavailability. In section 5, a combination of these two methods is analyzed. A general

  12. Waste Handling Equipment Development Test and Evaluation Study

    International Nuclear Information System (INIS)

    R.L. Tome

    1998-01-01

    The purpose of this study is to identify candidate Monitored Geologic Repository (MGR) surface waste handling equipment for development testing. This study will also identify strategies for performing the development tests. Development testing shall be implemented to support detail design and reduce design risks. Development testing shall be conducted to confirm design concepts, evaluate alternative design concepts, show the availability of needed technology, and provide design documentation. The candidate equipment will be selected from MGR surface waste handling equipment that is the responsibility of the Management and Operating Contractor (M and O) Surface Design Department. The equipment identified in this study is based on Viability Assessment (VA) design. The ''Monitored Geologic Repository Test and Evaluation Plan'' (MGR T and EP), Reference 5.1, was used as a basis for this study. The MGR T and EP reflects the extent of test planning and analysis that can be conducted, given the current status of the MGR requirements and latest VA design information. The MGR T and EP supports the appropriate sections in the license application (LA) in accordance with 10 CFR 60.2 1(c)(14). The MGR T and EP describes the following test activities: site characterization to confirm, by test and analysis, the suitability of the Yucca Mountain site for housing a geologic repository; development testing to investigate and document design concepts to reduce risk; qualification testing to verify equipment compliance with design requirements, specifications, and regulatory requirements; system testing to validate compliance with MGR requirements, which include the receipt, handling, retrieval, and disposal of waste; periodic performance testing to verify preclosure requirements and to demonstrate safe and reliable MGR operation; and performance confirmation modeling, testing, and analysis to verify adherence to postclosure regulatory requirements. Development test activities can be

  13. Operations monitoring concept. Consolidated Fuel Reprocessing Program

    International Nuclear Information System (INIS)

    Kerr, H.T.

    1985-01-01

    Operations monitoring is a safeguards concept which could be applied in future fuel cycle facilities to significantly enhance the effectiveness of an integrated safeguards system. In general, a variety of operations monitoring techniques could be developed for both international and domestic safeguards application. The goal of this presentation is to describe specific examples of operations monitoring techniques as may be applied in a fuel reprocessing facility. The operations monitoring concept involves monitoring certain in-plant equipment, personnel, and materials to detect conditions indicative of the diversion of nuclear material. An operations monitoring subsystem should be designed to monitor operations only to the extent necessary to achieve specified safeguards objectives; there is no intent to monitor all operations in the facility. The objectives of the operations monitoring subsystem include: verification of reported data; detection of undeclared uses of equipment; and alerting the inspector to potential diversion activities. 1 fig

  14. Damage limits of accelerator equipment

    CERN Document Server

    Rosell, Gemma

    2014-01-01

    Beam losses occur in particle accelerators for various reasons. The effect of lost particles on accelerator equipment becomes more severe with the increasing energies and intensities. The present study is focused on the damage potential of the proton beam as a function of particle energy and beam size. Injection and extraction energies of different accelerators at CERN were considered.

  15. Pocket dictionary of laboratory equipment

    International Nuclear Information System (INIS)

    Junge, H.D.

    1987-01-01

    This pocket dictionary contains the 2500 most common terms for scientific and technical equipment in chemical laboratories. It is a useful tool for those who are used to communicating in German and English, but have to learn the special terminology in this field. (orig.) [de

  16. Using Gaming Equipment to Teach

    Science.gov (United States)

    Curriculum Review, 2009

    2009-01-01

    Gaming equipment (such as Nintendo's Wii[TM]) is making its way to schools and classrooms. However, most of the discussion regarding how to use this technology and integrate it into lesson plans is happening in blogs on the Internet. An advocate of interactive media in the classroom, Dr. Dawn Hawkins, a faculty member for the Art Institute of…

  17. Isotope-equipped measuring instruments

    International Nuclear Information System (INIS)

    Miyagawa, Kazuo; Amano, Hiroshi

    1980-01-01

    In the steel industry, though the investment in isotope-equipped measuring instruments is small as compared with that in machinery, they play important role in the moisture measurement in sintering and blast furnaces, the thickness measurement in rolling process and others in automatic control systems. The economic aspect of the isotope-equipped measuring instruments is described on the basis of the practices in Kimitsu Works of Nippon Steel Corporation: distribution of such instruments, evaluation of economic effects, usefulness evaluation in view of raising the accuracy, and usefulness evaluation viewed from the failure of the isotope instruments. The evaluation of economic effects was made under the premise that the isotope-equipped measuring instruments are not employed. Then, the effects of raising the accuracy are evaluated for a γ-ray plate thickness gauge and a neutron moisture gauge for coke in a blast furnace. Finally, the usefulness was evaluated, assuming possible failure of the isotope-equipped measuring instruments. (J.P.N.)

  18. Hydraulic turbines and auxiliary equipment

    Energy Technology Data Exchange (ETDEWEB)

    Luo Gaorong [Organization of the United Nations, Beijing (China). International Centre of Small Hydroelectric Power Plants

    1995-07-01

    This document presents a general overview on hydraulic turbines and auxiliary equipment, emphasizing the turbine classification, in accordance with the different types of turbines, standard turbine series in China, turbine selection based on the basic data required for the preliminary design, general hill model curves, chart of turbine series and the arrangement of application for hydraulic turbines, hydraulic turbine testing, and speed regulating device.

  19. High level radioactive waste vitrification process equipment component testing

    International Nuclear Information System (INIS)

    Siemens, D.H.; Heath, W.O.; Larson, D.E.; Craig, S.N.; Berger, D.N.; Goles, R.W.

    1985-04-01

    Remote operability and maintainability of vitrification equipment were assessed under shielded-cell conditions. The equipment tested will be applied to immobilize high-level and transuranic liquid waste slurries that resulted from plutonium production for defense weapons. Equipment tested included: a turntable for handling waste canisters under the melter; a removable discharge cone in the melter overflow section; a thermocouple jumper that extends into a shielded cell; remote instrument and electrical connectors; remote, mechanical, and heat transfer aspects of the melter glass overflow section; a reamer to clean out plugged nozzles in the melter top; a closed circuit camera to view the melter interior; and a device to retrieve samples of the glass product. A test was also conducted to evaluate liquid metals for use in a liquid metal sealing system

  20. Low-energy house in Sisimiut - Measurement equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hvidthoeft Delff Andersen, P.; Rode, C.; Madsen, Henrik

    2013-08-15

    This paper documents the measurement equipment in a low-energy house in Sisimiut, Greenland. Detailed measurements are being taken on energy consumption, indoor temperatures, floor heating, ventilation, open/closed state of doors and windows, and indoors climate. Equipped with a central control unit, experiments can be designed in order to study heat dynamics of the building. It is described how to plan and execute such experiments in one apartment in the building. The building also features both a solar thermal system and extra buffer tank facilitating testing of storage strategies on the power generated by the solar thermal system. A weather station equipped with thermometer, pyranometer and anemometer is installed on the building as well. Finally, it is described how to retrieve data from an SQL server which is configured to take monthly backups. R functions have been implemented to fetch and prepare the data for time series analysis. Examples are given on the use of these. (Author)

  1. 77 FR 61737 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2012-10-11

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  2. 77 FR 37652 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2012-06-22

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... of export controls applicable to sensors and instrumentation equipment and technology. Agenda Public...

  3. 75 FR 1339 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2010-01-11

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  4. 77 FR 2270 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2012-01-17

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... the level of export controls applicable to sensors and instrumentation equipment and technology...

  5. 78 FR 1198 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-01-08

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  6. 76 FR 323 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2011-01-04

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  7. 78 FR 63161 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting...

    Science.gov (United States)

    2013-10-23

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting ``Rescheduled'' The Sensors and Instrumentation... that affect the level of export controls applicable to sensors and instrumentation equipment and...

  8. 75 FR 39920 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2010-07-13

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... of export controls applicable to sensors and instrumentation equipment and technology. Agenda Public...

  9. 78 FR 19638 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-04-02

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  10. 76 FR 63607 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2011-10-13

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  11. 78 FR 60251 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-10-01

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. [[Page...

  12. 78 FR 40098 - Sensors And Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-07-03

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors And Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... of export controls applicable to sensors and instrumentation equipment and technology. Agenda Public...

  13. 77 FR 23222 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2012-04-18

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... of export controls applicable to sensors and instrumentation equipment and technology. Agenda Public...

  14. 75 FR 14426 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2010-03-25

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... of export controls applicable to sensors and instrumentation equipment and technology. Agenda Public...

  15. 75 FR 62508 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2010-10-12

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  16. 75 FR 39919 - Information Systems, Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2010-07-13

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Information Systems, Technical Advisory Committee; Notice of Partially Closed Meeting The Information Systems Technical Advisory Committee (ISTAC... export controls applicable to information systems equipment and technology. Wednesday, July 28 Public...

  17. 78 FR 24160 - Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-04-24

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting The Information Systems Technical Advisory Committee (ISTAC... controls applicable to information systems equipment and technology. Tuesday, May 7 Open Session 1. Welcome...

  18. 75 FR 64258 - Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2010-10-19

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting The Information Systems Technical Advisory Committee (ISTAC... export controls applicable to information systems equipment and technology. Wednesday, November 3 Public...

  19. 78 FR 63162 - Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-10-23

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting The Information Systems Technical Advisory Committee (ISTAC... of export controls applicable to information systems equipment and technology. Wednesday, November 6...

  20. 78 FR 42753 - Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-07-17

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting The Information Systems Technical Advisory Committee (ISTAC... of export controls applicable to information systems equipment and technology. Wednesday, July 31...

  1. 76 FR 64895 - Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2011-10-19

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting The Information Systems Technical Advisory Committee (ISTAC... export controls applicable to information systems equipment and technology. Wednesday, November 2 Public...

  2. 76 FR 39845 - Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2011-07-07

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting The Information Systems Technical Advisory Committee (ISTAC... export controls applicable to information systems equipment and technology. Wednesday, July 27 Public...

  3. 78 FR 1198 - Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-01-08

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting The Information Systems Technical Advisory Committee (ISTAC... to information systems equipment and technology. Wednesday, January 23 Open Session 1. Welcome and...

  4. 77 FR 24178 - Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2012-04-23

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting The Information Systems Technical Advisory Committee (ISTAC... controls applicable to information systems equipment and technology. Tuesday, May 8 Open Session 1. Welcome...

  5. 77 FR 37652 - Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2012-06-22

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Information Systems Technical Advisory Committee; Notice of Partially Closed Meeting The Information Systems Technical Advisory Committee (ISTAC... that affect the level of export controls applicable to information systems equipment and technology...

  6. 77 FR 1666 - Information Systems, Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2012-01-11

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Information Systems, Technical Advisory Committee; Notice of Partially Closed Meeting The Information Systems Technical Advisory Committee (ISTAC... information systems equipment and technology. Wednesday, January 25 Open Session 1. Welcome and Introductions...

  7. High voltage disconnect switch position monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Crampton, S W

    1983-08-01

    Unreliable position indication on high-voltage (HV) disconnect switches can result in equipment damage worth many times the cost of a disconnect switch. The benefits and limitations of a number of possible methods of reliably monitoring HV disconnect switches are assessed. Several methods of powering active devices at HV are noted. It is concluded that the most reliable way of monitoring switch position at reasonable cost would use a passive hermetically-sealed blade-position sensor located at HV, with a fibre-optic link between HV and ground. Separate sensors would be used for open and closed position indication. For maximum reliability the fibre-optic link would continue into the relay building. A passive magnetically actuated fibre-optic sensor has been built which demonstrates the feasibility of the concept. The sensor monitors blade position relative to the jaws in three dimensions with high resolution. A design for an improved passive magneto-optic sensor has significantly lower optical losses, allowing a single fibre-optic loop and 3 sensors to monitor closure of all phases of a disconnect switch. A similar loop would monitor switch opening. The improved sensor has a solid copper housing to provide greater immunity to fault currents, and to protect it from the environment and from physical damage. Two methods of providing a protected path for fibre-optics passing from HV to ground are proposed, one using a hollow porcelain switch-support insulator and the other using an additional small-diameter polymer insulator with optical fibres imbedded in its fibreglass core. A number of improvements are recommended which can be made to existing switches to increase their reliability. 16 refs., 13 figs., 1 tab.

  8. A Review of the Soldier’s Equipment Burden

    Science.gov (United States)

    2011-12-01

    allow heavy items to be packed close to the soldier’s natural centre of mass . The Infantryman, with such a large equipment burden, is in effect...COM Centre of Mass COTS Commercial Off-the-Shelf CPL Corporal DARPA Defense Advanced Research Project Agency DMO Defence Materiel...Eighteen soldiers had customised their packs, either the issued packs or their own. The most common customisation was the addition of an external

  9. Contamination monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Alamares, A L [Philippine Nuclear Research Inst., Diliman, Quezon City (Philippines)

    1997-06-01

    By virture of Republic Act 2067, as amended the Philippine Atomic Energy Commission (PAEC), now renamed Philippine Nuclear Research Institute (PNRI) is the government agency charged with the regulations and control of radioactive materials in the Philippines. The protection against the hazards of non-ionizing radiation is being monitored by the Radiological Health Service (RHS) of the Department of Health pursuant to the provision of Presidental Decree 480. The RHS issues licenses for possession, handling, and use of x-ray machines and equipment, both industrial and medical, and provide radiation protection training to x-ray technologists and technicians. As part of its regulatory function, the PNRI is charged with the responsibility of assuring that the radiation workers and the public are protected from the hazards associated with the possession, handling, production, manufacturing, and the use of radioactive materials and atomic energy facilities in the Philippines. The protection of radiation workers from the hazards of ionizing radiation has always been a primary concern of PNRI and by limiting the exposure of radiation workers, the risk to population is kept to within acceptable level. In this paper, the following items are described: radiation protection program, radiation protection services, radiation control, and problems encountered/recommendation. (G.K.)

  10. Post-accident radiation monitors

    International Nuclear Information System (INIS)

    Laughlin, G.J.; Kathren, R.L.

    1982-01-01

    Under contract to the Nuclear Safety Analysis Center of the Electric Power Research Institute, technical information and specifications were obtained for commercially available radiological monitoring instrumentation designed for use as post-accident monitors. The information was collated and published in the NSAC Handbook of Postaccident Instrumentation (Kathren and Laughlin 1981), and included such data as range, accuracy, precision, sensitivity, and energy dependence of the detector, environmental and seismic limitations of the equipment, the testing program performed to evaluate the equipment, a list of references where the instrumentation is currently installed, and a list of features and accessories available with the monitoring systems. The information presented in this section reveals that, even though a number of vendors claim to be able to meet the guidance of Regulatory Guide 1.97 (USNRC 1980), few have actually conducted tests to verify that their equipment does indeed satisfy the guidance of this Regulatory Guide, and that some of the guidance may in fact be unrealistic

  11. Alternative Fuels Data Center: Biodiesel Equipment Options

    Science.gov (United States)

    Equipment Options to someone by E-mail Share Alternative Fuels Data Center: Biodiesel Equipment Options on Facebook Tweet about Alternative Fuels Data Center: Biodiesel Equipment Options on Twitter Bookmark Alternative Fuels Data Center: Biodiesel Equipment Options on Google Bookmark Alternative Fuels

  12. 40 CFR 792.61 - Equipment design.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Equipment design. 792.61 Section 792.61...) GOOD LABORATORY PRACTICE STANDARDS Equipment § 792.61 Equipment design. Equipment used in the... of appropriate design and adequate capacity to function according to the protocol and shall be...

  13. 40 CFR 160.61 - Equipment design.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Equipment design. 160.61 Section 160... LABORATORY PRACTICE STANDARDS Equipment § 160.61 Equipment design. Equipment used in the generation... appropriate design and adequate capacity to function according to the protocol and shall be suitably located...

  14. 21 CFR 58.61 - Equipment design.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Equipment design. 58.61 Section 58.61 Food and... PRACTICE FOR NONCLINICAL LABORATORY STUDIES Equipment § 58.61 Equipment design. Equipment used in the... of appropriate design and adequate capacity to function according to the protocol and shall be...

  15. 34 CFR 74.34 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... as program income. (e) When acquiring replacement equipment, the recipient may use the equipment to... replacement equipment subject to the approval of the Secretary. (f) The recipient's property management... 34 Education 1 2010-07-01 2010-07-01 false Equipment. 74.34 Section 74.34 Education Office of the...

  16. 20 CFR 437.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... contemplated by Federal statute. (4) When acquiring replacement equipment, the grantee or subgrantee may use.... Procedures for managing equipment (including replacement equipment), whether acquired in whole or in part... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Equipment. 437.32 Section 437.32 Employees...

  17. 45 CFR 2541.320 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... replacement equipment, the grantee or subgrantee may use the equipment to be replaced as a trade-in or sell... replacement equipment), whether acquired in whole or in part with grant funds, until disposition takes place... ensure the highest possible return. (e) Disposition. When original or replacement equipment acquired...

  18. 45 CFR 1174.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... contemplated by Federal statute. (4) When acquiring replacement equipment, the grantee or subgrantee may use... requirements. Procedures for managing equipment (including replacement equipment), whether acquired in whole or... original or replacement equipment acquired under a grant or subgrant is no longer needed for the original...

  19. 45 CFR 1157.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... contemplated by Federal statute. (4) When acquiring replacement equipment, the grantee or subgrantee may use... requirements. Procedures for managing equipment (including replacement equipment), whether acquired in whole or... original or replacement equipment acquired under a grant or subgrant is no longer needed for the original...

  20. The Cost of Maintaining Educational Communications Equipment.

    Science.gov (United States)

    Humphrey, David A.

    Tentative formulas for calculating the cost of maintaining educational communications equipment are proposed. The formulas are based on a survey of campuses of the State University of New York. The survey analyzed the types of equipment to be maintained, types of maintenance, who uses the equipment, who services the equipment, and the cost…

  1. TCR remote monitoring for the LHC technical infrastructure

    CERN Document Server

    Blanc, D; Morodo-Testa, M C; Poulsen, S; CERN. Geneva. ST Division

    2003-01-01

    The remote monitoring of the LHC technical infrastructure will mainly be done in CERN’s Technical Control Room (TCR). The technical infrastrucure consists of specialised equipment from different groups and divisions, mainly cooling and ventilation and electrical equipment. The responsibility for the definition, operation and maintenance of the equipment is covered by the relevant equipment group. However the monitoring and alerting for action in case of equipment failure is initiated by the TCR and is based on alarms that are sent by the equipment. This implies the correct integration of the equipment and the establishment of rules to follow during the commissioning and start-up of the equipment in order to ensure proper operation. This paper shows the integration possibilities and the different tasks and steps to follow by the different parties for smooth equipment integration and avoiding organizational problems.

  2. Environmental radiation monitoring system

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Shioiri, Masatoshi; Sakamaki, Tsuyoshi

    2007-01-01

    Environmental radiation monitoring systems are used to measure and monitoring gamma-rays at the observation boundaries of nuclear facilities and in the surrounding areas. In recent years, however, few new nuclear facilities have been constructed and the monitoring systems shift to renewal of existing systems. In addition, in order to increase public acceptance, the facilities are being equipped with communication lines to provide data to prefectural environmental centers. In this text, we introduce the latest technology incorporated in replacement of environmental radiation monitoring systems. We also introduce a replacement method that can shorten the duration during which environmental dose rate measurement is interrupted by enabling both the replacement system and the system being replaced to perform measurements in parallel immediately before and after the replacement. (author)

  3. Closing the fuel cycle

    International Nuclear Information System (INIS)

    Aycoberry, C.; Rougeau, J.P.

    1987-01-01

    The progressive implementation of some key nuclear fuel cycle capecities in a country corresponds to a strategy for the acquisition of an independant energy source, France, Japan, and some European countries are engaged in such strategic programs. In France, COGEMA, the nuclear fuel company, has now completed the industrial demonstration of the closed fuel cycle. Its experience covers every step of the front-end and of the back-end: transportation of spent fuels, storage, reprocessing, wastes conditioning. The La Hague reprocessing plant smooth operation, as well as the large investment program under active progress can testify of full mastering of this industry. Together with other French and European companies, COGEMA is engaged in the recycling industry, both for uranium through conversion of uranyl nitrate for its further reeichment, and for plutonium through MOX fuel fabrication. Reprocessing and recycling offer the optimum solution for a complete, economic, safe and future-oriented fuel cycle, hence contributing to the necessary development of nuclear energy. (author)

  4. The closed fuel cycle

    International Nuclear Information System (INIS)

    Froment, Antoine; Gillet, Philippe

    2007-01-01

    Available in abstract form only. Full text of publication follows: The fast growth of the world's economy coupled with the need for optimizing use of natural resources, for energy security and for climate change mitigation make energy supply one of the 21. century most daring challenges. The high reliability and efficiency of nuclear energy, its competitiveness in an energy market undergoing a new oil shock are as many factors in favor of the 'renaissance' of this greenhouse gas free energy. Over 160,000 tHM of LWR1 and AGR2 Used Nuclear Fuel (UNF) have already been unloaded from the reactor cores corresponding to 7,000 tons discharged per year worldwide. By 2030, this amount could exceed 400,000 tHM and annual unloading 14,000 tHM/year. AREVA believes that closing the nuclear fuel cycle through the treatment and recycling of Used Nuclear Fuel sustains the worldwide nuclear power expansion. It is an economically sound and environmentally responsible choice, based on the preservation of natural resources through the recycling of used fuel. It furthermore provides a safe and secure management of wastes while significantly minimizing the burden left to future generations. (authors)

  5. Gas liquid sampling for closed canisters in KW Basin - test plan

    International Nuclear Information System (INIS)

    Pitkoff, C.C.

    1995-01-01

    Test procedures for the gas/liquid sampler. Characterization of the Spent Nuclear Fuel, SNF, sealed in canisters at KW-Basin is needed to determine the state of storing SNF wet. Samples of the liquid and the gas in the closed canisters will be taken to gain characterization information. Sampling equipment has been designed to retrieve gas and liquid from the closed canisters in KW basin. This plan is written to outline the test requirements for this developmental sampling equipment

  6. 46 CFR 153.284 - Characteristics of required quick closing valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Characteristics of required quick closing valves. 153.284 Section 153.284 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK... and Equipment Piping Systems and Cargo Handling Equipment § 153.284 Characteristics of required quick...

  7. Foodstuffs, radionuclides, monitoring

    International Nuclear Information System (INIS)

    Denisikov, A.I.

    2000-01-01

    Radionuclide contamination of water and food stuffs as a result of the Chernobyl accident and permissible contents of 90 Sr and 137 Cs are considered in brief. A method of radiation monitoring of food stuffs and water for the radionuclides mentioned is suggested. The method permits employment of the simplest and cheapest radiometric equipment for analysis, whole the high degree of radionuclide concentration using fiber sorbents permits using the instrumentation without expensive shields against external radiation. A description of ion-exchange unit for radiation monitoring of liquid samples of food stuffs or water, is provided [ru

  8. Wide area monitoring study

    International Nuclear Information System (INIS)

    Wogman, N.A.; Holdren, G.R. Jr.

    1999-01-01

    Environmental sampling can be used to complement the safeguarding of nuclear material, especially in the detection of undeclared nuclear activities. Routine monitoring of nuclear installations has provided valuable information about the fate of key signature materials within different environmental settings. The approach collates information regarding the generation of individual radiochemical signatures within different nuclear processes, the potential for release of these signatures to the environment and, the chemical form and mobility of the signatures in environmental media along which the material could migrate. Meteorological, geological and hydrological information is used to determine where to sample, what to sample, and how often to sample to provide the greatest likelihood for detection. Multiple strategies can be used to implement wide area monitoring for safeguards purposes. The most complex, and expensive of these, involves establishing extensive networks of fixed location sampling sites. The sites would be operated continuously, and would be instrumented with automated sampling, analysis, and communication equipment to relay information regarding potential anomalies to control centers in near-real time. Alternative strategies can be used to supplement fixed location monitoring equipment, especially in regions that cannot support (financially or logistically) the fixed stations. Through combinations of these various strategies, using a variety of environmental media to monitor a region, we believe that a competent network, one with a quantifiable probability for detecting undeclared nuclear activities, can be designed. While this approach cannot and should not replace other inspection and monitoring activities, it can potentially contribute valuable information to an international safeguards system. (author)

  9. Closed cooling water chemistry guidelines revision

    International Nuclear Information System (INIS)

    McElrath, Joel; Breckenridge, Richard

    2014-01-01

    This second revision of the Closed Cooling Water Chemistry Guideline addresses the use of chemicals and monitoring methods to mitigate corrosion, fouling, and microbiological growth in the closed cooling-water (CCW) systems of nuclear and fossil-fueled power plants. This revision has been endorsed by the utility chemistry community and represents another step in developing a more proactive chemistry program to limit or control closed cooling system degradation with increased consideration of corporate resources and plant-specific design and operating concerns. These guidelines were developed using laboratory data, operating experience, and input from organizations and utilities within and outside of the United States of America. It is the intent of the Revision Committee that these guidelines are applicable to all nuclear and fossil-fueled generating stations around the world. A committee of industry experts—including utility specialists, Institute of Nuclear Power Operations representatives, water-treatment service-company representatives, consultants, a primary contractor, and EPRI staff—collaborated in reviewing available data on closed cooling-water system corrosion and microbiological issues. Recognizing that each plant owner has a unique set of design, operating, and corporate concerns, the Guidelines Committee developed a methodology for plant-specific optimization. The guideline provides the technical basis for a reasonable but conservative set of chemical treatment and monitoring programs. The use of operating ranges for the various treatment chemicals discussed in this guideline will allow a power plant to limit corrosion, fouling, and microbiological growth in CCW systems to acceptable levels. The guideline now includes closed cooling chemistry regimes proven successful in use in the international community. The guideline provides chemistry constraints for the use of phosphates control, as well as pure water with pH control. (author)

  10. Bangladesh Agro-Climatic Environmental Monitoring Project

    Science.gov (United States)

    Vermillion, C.; Maurer, H.; Williams, M.; Kamowski, J.; Moore, T.; Maksimovich, W.; Obler, H.; Gilbert, E.

    1988-01-01

    The Agro-Climatic Environmental Monitoring Project (ACEMP) is based on a Participating Agency Service Agreement (PASA) between the Agency for International Development (AID) and the National Oceanic and Atmospheric Administration (NOAA). In FY80, the Asia Bureau and Office of Federal Disaster Assistance (OFDA), worked closely to develop a funding mechanism which would meet Bangladesh's needs both for flood and cyclone warning capability and for application of remote sensing data to development problems. In FY90, OFDA provided for a High Resolution Picture Transmission (HRPT) receiving capability to improve their forecasting accuracy for cyclones, flooding and storm surges. That equipment is primarily intended as a disaster prediction and preparedness measure. The ACEM Project was designed to focus on the development applications of remote sensing technology. Through this Project, AID provided to the Bangladesh Government (BDG) the equipment, technical assistance, and training necessary to collect and employ remote sensing data made available by satellites as well as hydrological data obtained from data collection platforms placed in major rivers. The data collected will enable the BDG to improve the management of its natural resources.

  11. Equipment reliability process improvement and preventive maintenance optimization

    International Nuclear Information System (INIS)

    Darragi, M.; Georges, A.; Vaillancourt, R.; Komljenovic, D.; Croteau, M.

    2004-01-01

    The Gentilly-2 Nuclear Power Plant wants to optimize its preventive maintenance program through an Integrated Equipment Reliability Process. All equipment reliability related activities should be reviewed and optimized in a systematic approach especially for aging plants such as G2. This new approach has to be founded on best practices methods with the purpose of the rationalization of the preventive maintenance program and the performance monitoring of on-site systems, structures and components (SSC). A rational preventive maintenance strategy is based on optimized task scopes and frequencies depending on their applicability, critical effects on system safety and plant availability as well as cost-effectiveness. Preventive maintenance strategy efficiency is systematically monitored through degradation indicators. (author)

  12. Council of Europe closes post monitoring of Latvia / Aaron Eglitis

    Index Scriptorium Estoniae

    Eglitis, Aaron

    2005-01-01

    Euroopa Nõukogu lõpetas Lätis vähemusrahvuste olukorra jälgimise. Parlamentaarse Assamblee monitooringukomitee esimees Gyorgy Frunda pidas ettekande olukorrast Lätis ja riigi tegevusest rahvusvähemuste kaitse konventsiooni ratifitseerimisel

  13. High current vacuum closing switch

    International Nuclear Information System (INIS)

    Dolgachev, G.I.; Maslennikov, D.D.; Romanov, A.S.; Ushakov, A.G.

    2005-01-01

    The paper proposes a powerful pulsed closing vacuum switch for high current commutation consisting of series of the vacuum diodes with near 1 mm gaps having closing time determined by the gaps shortening with the near-electrode plasmas [ru

  14. Maintenance cost avoidance through comprehensive condition monitoring

    International Nuclear Information System (INIS)

    Miller, G.P.; McClymonds, S.L.

    1990-01-01

    Condition monitoring, the measurement and trending of a critical parameter for predictive maintenance, has reached new levels of acceptance and application within the utility and manufacturing industry. Commercially available systems extend well beyond traditional vibration-monitoring systems to include such areas as online wear, crack and leak detection, and stress monitoring. The challenge facing industry is to integrate the information generated from condition monitoring. Current studies indicate that the effectiveness of predictive maintenance depends much more on the program that is established to apply the monitoring techniques than on the monitoring equipment itself. This paper presents a five-phase approach to developing a condition monitoring program

  15. Close to the Sky

    Science.gov (United States)

    2007-11-01

    Today, a new ALMA outreach and educational book was publicly presented to city officials of San Pedro de Atacama in Chile, as part of the celebrations of the anniversary of the Andean village. ESO PR Photo 50a/07 ESO PR Photo 50a/07 A Useful Tool for Schools Entitled "Close to the sky: Biological heritage in the ALMA area", and edited in English and Spanish by ESO in Chile, the book collects unique on-site observations of the flora and fauna of the ALMA region performed by experts commissioned to investigate it and to provide key initiatives to protect it. "I thank the ALMA project for providing us a book that will surely be a good support for the education of children and youngsters of San Pedro de Atacama. Thanks to this publication, we expect our rich flora and fauna to be better known. I invite teachers and students to take advantage of this educational resource, which will be available in our schools", commented Ms. Sandra Berna, the Mayor of San Pedro de Atacama, who was given the book by representatives of the ALMA global collaboration project. Copies of the book 'Close to the sky' will be donated to all schools in the area, as a contribution to the education of students and young people in northern Chile. "From the very beginning of the project, ALMA construction has had a firm commitment to environment and local culture, protecting unique flora and fauna species and preserving old estancias belonging to the Likan Antai culture," said Jacques Lassalle, who represented ALMA at the hand-over. "Animals like the llama, the fox or the condor do not only live in the region where ALMA is now being built, but they are also key elements of the ancient Andean constellations. In this sense they are part of the same sky that will be explored by ALMA in the near future." ESO PR Photo 50c/07 ESO PR Photo 50c/07 Presentation of the ALMA book The ALMA Project is a giant, international observatory currently under construction on the high-altitude Chajnantor site in Chile

  16. Closed cycle device

    International Nuclear Information System (INIS)

    Ruby, L.E.; Witt, D.L.; Staley, C.F.

    1975-01-01

    A gas dynamic laser wherein the lasing fluid is recirculated in a closed loop is described. The flow can be assumed to start with the lasing gas passing through a cascade of supersonic nozzles. This low pressure, high velocity gas is then passed through a lasing cavity where the lasing action takes place. The energy of the high velocity gas stream is converted back to static pressure in a supersonic diffuser. The diffuser is constructed with (1) variable geometry, and (2) provisions for bleeding off the boundary layer for improved efficiency. Downstream of the supersonic diffuser there is a heat exchanger which partially cools the gas in the loop. This partially cooled gas is then supplied to a compressor where the pressure and temperature are raised back to the level at the start of the flow. The lasing gas is directed from the exit of the compressor to a manifold upstream of the cascade of supersonic nozzles. The compressor only supplies a pressure rise equal to the pressure loss by inefficiencies in the nozzle, the supersonic diffuser and the pressure drop in the heatexchanger and plumbing. To provide for cooling of the compressor, the gas bled from the diffuser is cooled by a second heat exchanger and pumped back to compressor inlet pressure and introduced into the compressor for cooling. In steady state operation, both heat exchangers referred to above, are designed to regulatethe nozzle inlet gas temperature by removing the amount of heat energy added by compressing minus the amount of energy extracted in the lasing beam and energy lost to the environment. The compressor and pumping means for cooling the compressor can be driven by any means desired. (U.S.)

  17. Large-component handling equipment and its use

    International Nuclear Information System (INIS)

    Krieg, S.A.; Swannack, D.L.

    1983-01-01

    The Fast Flux Test Facility (FFTF) reactor systems have special requirements for component replacements during maintenance servicing. Replacement operations must address handling of equipment within shielded metal containers while maintaining an inert atmosphere to prevent reaction of sodium with air. Plant identification of a failed component results in selecting and assembling the maintenance cask and equipment transport system for transfer from the storage facility to the Reactor Containment Building (RCB). This includes a proper diameter and length cask, inert atmosphere control consoles, component lift fixture and support structure for interface with the facility area surrounding the component. This equipment is staged in modular groups in the Reactor Service Building for transfer through the equipment airlock to the containment interior. The failed component is generally prepared for replacement by installation of the special lifting fixture attachment. Assembly of the cask support structure is performed over the component position on the containment building operating floor. The cask and shroud from the reactor interface are inerted after all manual service connections and handling attachments are completed. The component is lifted from the reactor and into the cask interior through a floor valve which is then closed to isolate the component reactor port. The cask with sodium wetted component is transferred to a service/repair location, either within containment or outside, to the Maintenance Facility cleaning and repair area. The complete equipment and handling operations for replacement of a large reactor component are described

  18. [Equipment and technology in robotics].

    Science.gov (United States)

    Murphy, Declan; Challacombe, Ben; Nedas, Tim; Elhage, Oussama; Althoefer, Kaspar; Seneviratne, Lakmal; Dasgupta, Prokar

    2007-05-01

    We review the evolution and current status of robotic equipment and technology in urology. We also describe future developments in the key areas of virtual reality simulation, mechatronics and nanorobotics. The history of robotic technology is reviewed and put into the context of current systems. Experts in the associated fields of nanorobotics, mechatronics and virtual reality simulation simulation review the important future developments in these areas.

  19. Remote handling equipment for SNS

    International Nuclear Information System (INIS)

    Poulten, B.H.

    1983-01-01

    This report gives information on the areas of the SNS, facility which become highly radioactive preventing hands-on maintenance. Levels of activity are sufficiently high in the Target Station Area of the SNS, especially under fault conditions, to warrant reactor technology to be used in the design of the water, drainage and ventilation systems. These problems, together with the type of remote handling equipment required in the SNS, are discussed

  20. Margins related to equipment design

    International Nuclear Information System (INIS)

    Devos, J.

    1994-01-01

    Safety margins related to design of reactor equipment are defined according to safety regulations. Advanced best estimate methods are proposed including some examples which were computed and compared to experimental results. Best estimate methods require greater computation effort and more material data but give better variable accuracy and need careful experimental validation. Simplified methods compared to the previous are less sensitive to material data, sometimes are more accurate but very long to elaborate

  1. Temperature radiation measuring equipment. Temperaturstrahlungsmessgeraet

    Energy Technology Data Exchange (ETDEWEB)

    Lotzer, W

    1981-01-22

    The invention is concerned with a temperature radiation measuring equipment for non-contact temperature measurement by the light intensity variation method, with a photoelectric resistance as the measuring element. By having a circuit with a transistor, the 'dark resistance' occurring in the course of time is compensated for and thus gives a genuine reading (ie. the voltage drop across the photoelectric resistance remains constant).

  2. 500 MHz narrowband beam position monitor electronics for electron synchrotrons

    International Nuclear Information System (INIS)

    Mohos, I.; Dietrich, J.

    1998-01-01

    Narrowband beam position monitor electronics were developed in the Forschungszentrum Juelich-IKP for the orbit measurement equipment used at ELSA Bonn. The equipment uses 32 monitor chambers, each with four capacitive button electrodes. The monitor electronics, consisting of an rf signal processing module (BPM-RF) and a data acquisition and control module (BPM-DAQ), sequentially process and measure the monitor signals and deliver calculated horizontal and vertical beam position data via a serial network

  3. 500 MHz narrowband beam position monitor electronics for electron synchrotrons

    Science.gov (United States)

    Mohos, I.; Dietrich, J.

    1998-12-01

    Narrowband beam position monitor electronics were developed in the Forschungszentrum Jülich-IKP for the orbit measurement equipment used at ELSA Bonn. The equipment uses 32 monitor chambers, each with four capacitive button electrodes. The monitor electronics, consisting of an rf signal processing module (BPM-RF) and a data acquisition and control module (BPM-DAQ), sequentially process and measure the monitor signals and deliver calculated horizontal and vertical beam position data via a serial network.

  4. CERN computing equipment for Senegal

    CERN Multimedia

    Anaïs Schaeffer

    2014-01-01

    On 26 May, CERN once again had the honour of donating computing equipment to a foreign institute.   This time, around 100 servers and five network hubs were sent to Senegal, making it the seventh country, after Morocco, Ghana, Bulgaria, Serbia, Egypt and the Philippines, to receive a donation of computing equipment from the Organization. The official ceremony was held at CERN on 26 May in the presence of the Director-General, Rolf Heuer, and Senegal's ambassador to Geneva, Fodé Seck, who both expressed their enthusiasm for the project. The equipment is intended for Cheikh Anta Diop University (UCAD) in Dakar and will be of particular use to students attending the African School of Fundamental Physics and its Applications (ASP 2014) taking place from 3 to 23 August, for which CERN is a partner. The ASP allows a large number of African students to hone their skills in high-energy physics and to forge professional links with fellow physicists in Africa and Europe. ...

  5. 40 CFR 63.751 - Monitoring requirements.

    Science.gov (United States)

    2010-07-01

    ... challenge the monitors with compounds representative of the gaseous emission stream being controlled. (B) If... substantial heat exchange occurs. (10) Where a catalytic incinerator is used, thermocouples, each equipped...

  6. Collaborative Monitoring and Hazard Mitigation at Fuego Volcano, Guatemala

    Science.gov (United States)

    Lyons, J. J.; Bluth, G. J.; Rose, W. I.; Patrick, M.; Johnson, J. B.; Stix, J.

    2007-05-01

    A portable, digital sensor network has been installed to closely monitor changing activity at Fuego volcano, which takes advantage of an international collaborative effort among Guatemala, U.S. and Canadian universities, and the Peace Corps. The goal of this effort is to improve the understanding shallow internal processes, and consequently to more effectively mitigate volcanic hazards. Fuego volcano has had more than 60 historical eruptions and nearly-continuous activity make it an ideal laboratory to study volcanic processes. Close monitoring is needed to identify base-line activity, and rapidly identify and disseminate changes in the activity which might threaten nearby communities. The sensor network is comprised of a miniature DOAS ultraviolet spectrometer fitted with a system for automated plume scans, a digital video camera, and two seismo-acoustic stations and portable dataloggers. These sensors are on loan from scientists who visited Fuego during short field seasons and donated use of their sensors to a resident Peace Corps Masters International student from Michigan Technological University for extended data collection. The sensor network is based around the local volcano observatory maintained by Instituto National de Sismologia, Vulcanologia, Metrologia e Hidrologia (INSIVUMEH). INSIVUMEH provides local support and historical knowledge of Fuego activity as well as a secure location for storage of scientific equipment, data processing, and charging of the batteries that power the sensors. The complete sensor network came online in mid-February 2007 and here we present preliminary results from concurrent gas, seismic, and acoustic monitoring of activity from Fuego volcano.

  7. Ultrasound monitoring of inter-knee distances during gait.

    Science.gov (United States)

    Lai, Daniel T H; Wrigley, Tim V; Palaniswami, M

    2009-01-01

    Knee osteoarthritis is an extremely common, debilitating disease associated with pain and loss of function. There is considerable interest in monitoring lower limb alignment due to its close association with joint overload leading to disease progression. The effects of gait modifications that can lower joint loading are of particular interest. Here we describe an ultrasound-based system for monitoring an important aspect of dynamic lower limb alignment, the inter-knee distance during walking. Monitoring this gait parameter should facilitate studies in reducing knee loading, a primary risk factor of knee osteoarthritis progression. The portable device is composed of an ultrasound sensor connected to an Intel iMote2 equipped with Bluetooth wireless capability. Static tests and calibration results show that the sensor possesses an effective beam envelope of 120 degrees, with maximum distance errors of 10% at the envelope edges. Dynamic walking trials reveal close correlation of inter-knee distance trends between that measured by an optical system (Optotrak Certus NDI) and the sensor device. The maximum average root mean square error was found to be 1.46 cm. Future work will focus on improving the accuracy of the device.

  8. Patients Radiation Load Caused by Digitalised X-Ray Equipment

    International Nuclear Information System (INIS)

    Nikodemova, D.; Prikazska, M.; Horvathova, M.

    2001-01-01

    Full text: The radiation load of population all over the world from medical examinations clearly demonstrate the importance of implementation of quality assurance and quality control programmes into the activities of radiological departments. The basic aim of quality assurance programme is to ensure that the radiation dose is kept as low as reasonably practicable consistent with adequate image quality. As many other fields, the rapid development of techniques brought change-over from the conventional analogue technique to the digital technique. In this connection conventional X-ray film is being abandoned and images are being viewed on either laser film or monitor. The main advantages of using digital equipment lay in improved image quality and diagnostic accuracy through digital image processing, reduction in patient exposure, cost reduction by reduction film usage, more efficient storage and retrieval of radiographic images through picture archiving. Several studies that have been conducted for comparison of various diagnostic examinations performed on digital and analogue X-ray equipment have shown that in barium meal examinations, there is potential for dose saving in the digital image intensifier technique. The aim of this study was to compare measured values of dose-area product for colon investigations using different X-ray equipment types, on digital and one analogue. Our material consisted of 60 randomly selected patients, 24 of them were examined with digital equipment and 36 patients with the analogue equipment. (author)

  9. JCE Online: Equipment Buyers Guide

    Science.gov (United States)

    Holmes, Jon L.

    1999-01-01

    The Equipment Buyers Guide was edited by Jo Rita Jordan. The new Equipment Buyers Guide, bound into the back of this issue, is also a new resource of JCE Internet. This resource provides an online source for the information contained in the printed guide. Placing this information online allows us to regularly update it and to provide live links to the suppliers' WWW sites. The organization of the online version parallels that of the print version. There is an alphabetical list of suppliers and a categorical listing. Links to these lists are provided on every page in the left-hand navigation bar. To quickly find information about a particular supplier, you click Supplier List, click the letter that begins the supplier's name, and scroll through the list to find the supplier. To find which suppliers provide a particular type of instrument or equipment, use the Categories link; click the category of the equipment you are looking for and then click the link to a supplier. You will then be taken to an alphabetical supplier listing page where you can scroll until you find the particular supplier of the item for which you are looking. Once you have found a supplier, the online Equipment Buyers Guide gives you the traditional contact information. But in addition, you also get one-click access to the WWW sites of the suppliers that have them. Depending on the site, you should be able to find information about the items that you seek and may even be able to order the items online! We think that you will find the online version of the Equipment Buyers Guide useful. To make it more useful, please send your suggestions, any errors or omissions you find, and any additional categories to the editor at jjordan@world.std.com The online Equipment Buyers Guide can be found at JCE Online at http://JChemEd.chem.wisc.edu/JCEWWW/Resources/EBG/ JCE Online in '99 JCE Online is your online source of "all things JCE". In order to provide you with an even more useful online resource, JCE

  10. Used energy-related laboratory equipment grant program for institutions of higher learning. Eligible equipment catalog

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    This is a listing of energy related equipment available through the Energy-Related Laboratory Equipment Grant Program which grants used equipment to institutions of higher education for energy-related research. Information included is an overview of the program, how to apply for a grant of equipment, eligibility requirements, types of equipment available, and the costs for the institution.

  11. Steps in formulating an environmental monitoring program

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    This section describes the process of establishing a complete equipment environmental monitoring program; the step by step process is also illustrated in Table 3 of the Summary. The following decisions must be made in defining the program: an initial characterization of plant environment, how to integrate with existing programs to realize the maximum benefits, identification of the specific monitoring locations, determining the monitoring techniques, frequency of recording data, monitoring duration, quality assurance requirements, and finally, establishing the recordkeeping requirements

  12. HAPO Plant and capital equipment budget for FY 1966 and revision of budget for FY 1965 equipment not related to construction projects

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, J.E.

    1964-05-12

    This document is divided into: byproduct horizontal control rod system (5 reactors); high-speed scanning-effluent temperature monitoring system (KE reactor); improved reactor gas system (100-KE & KW); safety circuit system modifications (5 reactors); alternate process hot die sizing, 313 Building 300 Area; button line equipment (234-5 Building); in-tank waste solidification (3rd unit); and misc. minor equipment projects.

  13. Technology assessment of long distance liquid natural gas pipelines. Phase 9. Available and/or required equipment

    Energy Technology Data Exchange (ETDEWEB)

    1977-02-01

    This phase of the technology assessment of liquid natural gas pipelines assembles a listing of the materials and equipment which might be used to mechanically build an LNG pipeline. It lists material and equipment which practically could be used in such a pipeline either at a present state of the art, or by adaptation in terms of materials or techniques, or after some development work. Other than that the material and equipment is proposed for use in an LNG pipeline, no new real concept of pipeline or refrigeration plant equipment is proposed. Rather the equipment has been selected so as to conform as closely as possible to established pipeline practice.

  14. Cleaning and sterilisation of anaesthetic equipment

    Directory of Open Access Journals (Sweden)

    Chitra Sanjeev Juwarkar

    2013-01-01

    Full Text Available The main purpose of this review article is to bring up what has been known (practiced about decontamination, disinfection, and sterilisation of anaesthetic equipment. It also discusses how this evidence-based information on infection prevention and control impacts care of patient in routine anaesthesia practice. This review underscores the role played by us, anaesthetists in formulating guidelines, implementing the same, monitoring the outcome and training post-graduate trainees and coworkers in this regard. The article re-emphasises that certain guidelines when followed strictly will go a long way in reducing transmission of hospital acquired infection between patient and anaesthetist or between patients. Anaesthetists do not restrict their work to operating room but are involved in disaster management, interventional radiological procedures and in trauma care. They should ensure that the patients are cared for in clean and safe environment so as to reduce healthcare associated infections (HCAIs simultaneously taking preventive measures against the various health hazards associated with clinical practice. They should ensure that the coworkers too adopt all the preventive measures while delivering their duties. For this review, we conducted literature searches in Medline (PubMed and also searched for relevant abstracts and full texts of related articles that we came across. There is much to be learned from the western world where, health care organisations now have legal responsibility to implement changes in accordance with the newer technology to reduce health care associated infection. There is a need to develop evidence-based infection prevention and control programs and set national guidelines for disinfection and sterilisation of anaesthesia equipment which all the institutions should comply with.

  15. Spectral characteristics of seismic noise using data of Kazakhstan monitoring stations

    International Nuclear Information System (INIS)

    Mikhajlova, N.N.; Komarov, I.I.

    2006-01-01

    Spectral specifications of seismic noise research for PS23-Makanchi, Karatau, Akbulak, AS057-Borovoye and new three-component station AS059-Aktyubinsk was done. Spectral noise density models were obtained for day and night time and spectral density values variation. Noise close to low-level universal noise model is peculiar for all stations, which provides their high efficiency while seismic monitoring. Noise parameters dependence on seismic receivers installation conditions was investigated separately. Based on three stations (Makanchi, Borovoye, and Aktyubinsk), spectral density change features are shown after borehole equipment installation. (author)

  16. CEMs turn monitoring giant

    International Nuclear Information System (INIS)

    White, J.R.

    1993-01-01

    Crucial to complying with environmental regulations is selecting appropriate pollution control equipment to capture or destroy regulated pollutants. But just as important is selecting a continuous emissions monitoring system (CEM). CEMs play a dual role in an overall compliance strategy. On one hand, they identify the type and quantity of emissions at a source as a first step for determining which regulatory requirements and control technologies are applicable. They also provide ongoing emissions data to demonstrate compliance with air and other environmental regulations. Facilities are required to monitor their processes with CEMs, or a comparable technology, under several titles of the Clean Air Act Amendments of 1990. CEMs meet regulatory requirements if they include a SO 2 concentration monitor, nitrogen oxides (NO x ) concentration monitor, volumetric flow monitor, opacity monitor, diluent gas monitor and data acquisition and handling system. The entire system and each subsystem has to be installed and certified before it can be used for compliance. A written quality assurance/quality control (QA/QC) plan for the CEMs must accompany the permit application. The acid rain rules also impose performance standards and frequent calibration checks to ensure the integrity of CEMs data

  17. The research of medical equipment on-line detection system based on Android smartphone

    Science.gov (United States)

    Jiang, Junjie; Dong, Xinyu; Zhang, Hongjie; Liu, Mengjun

    2017-06-01

    With the unceasing enhancement of medical level, the expanding scale of medical institutions, medical equipment as an important tool for disease diagnosis, treatment and prevention, used in all levels of medical institutions. The quality and accuracy of the Medical equipment play a key role in the doctor's diagnosis and treatment effect, medical metrology as the important technical foundation is to ensure that the equipment, technology, material components are accurate and the application is safe and reliable. Medical equipment have the feature of variety, large quantity, long using cycle, expensive and multi-site, which bring great difficulty in maintenance, equipment management and verification. Therefore, how to get the medical measurement integrate deeply into the advanced internet technology, information technology and the new measuring method, for real-time monitoring of medical equipment, tracking, positioning, and query is particularly important.

  18. Device for closing the radioactive sources shutters

    International Nuclear Information System (INIS)

    Teixeira, Everaldo; Santos, Enderson Silvino; Vieira, Carlaine M.; Torquato, Nivaldo Reis; Santos, Evando Ramalho; Castro, Luciano Sampaio

    2002-01-01

    A device for nuclear measurement used at the industrial installation is composed of a radioactive source (Cs 137), the ionization or scintillation chamber and the circuitry parts. The ionization and scintillation chambers are mounted at the industrial piping and monitoring the density of the material inside the piping, based on radiation quantity which comes to receiving chamber. This information is sending to the electronic unity which is responsible for the calculations and remote and local indications of the measured density. Based on the recommendation of the radioactive sources must have the shutters closed when they are inactive, an automatic device composed by solenoid valve, a support and a mechanical shaft which when connected to the supervisory system (CLP's) cause the automatic closing of the shutter of the radioactive sources during the shutting down of the process

  19. Closed orbit feedback with digital signal processing

    International Nuclear Information System (INIS)

    Chung, Y.; Kirchman, J.; Lenkszus, F.

    1994-01-01

    The closed orbit feedback experiment conducted on the SPEAR using the singular value decomposition (SVD) technique and digital signal processing (DSP) is presented. The beam response matrix, defined as beam motion at beam position monitor (BPM) locations per unit kick by corrector magnets, was measured and then analyzed using SVD. Ten BPMs, sixteen correctors, and the eight largest SVD eigenvalues were used for closed orbit correction. The maximum sampling frequency for the closed loop feedback was measured at 37 Hz. Using the proportional and integral (PI) control algorithm with the gains Kp = 3 and K I = 0.05 and the open-loop bandwidth corresponding to 1% of the sampling frequency, a correction bandwidth (-3 dB) of approximately 0.8 Hz was achieved. Time domain measurements showed that the response time of the closed loop feedback system for 1/e decay was approximately 0.25 second. This result implies ∼ 100 Hz correction bandwidth for the planned beam position feedback system for the Advanced Photon Source storage ring with the projected 4-kHz sampling frequency

  20. Modeling closed nuclear fuel cycles processes

    Energy Technology Data Exchange (ETDEWEB)

    Shmidt, O.V. [A.A. Bochvar All-Russian Scientific Research Institute for Inorganic Materials, Rogova, 5a street, Moscow, 123098 (Russian Federation); Makeeva, I.R. [Zababakhin All-Russian Scientific Research Institute of Technical Physics, Vasiliev street 13, Snezhinsk, Chelyabinsk region, 456770 (Russian Federation); Liventsov, S.N. [Tomsk Polytechnic University, Tomsk, Lenin Avenue, 30, 634050 (Russian Federation)

    2016-07-01

    Computer models of processes are necessary for determination of optimal operating conditions for closed nuclear fuel cycle (NFC) processes. Computer models can be quickly changed in accordance with new and fresh data from experimental research. 3 kinds of process simulation are necessary. First, the VIZART software package is a balance model development used for calculating the material flow in technological processes. VIZART involves taking into account of equipment capacity, transport lines and storage volumes. Secondly, it is necessary to simulate the physico-chemical processes that are involved in the closure of NFC. The third kind of simulation is the development of software that allows the optimization, diagnostics and control of the processes which implies real-time simulation of product flows on the whole plant or on separate lines of the plant. (A.C.)