WorldWideScience

Sample records for clipping circuits

  1. Modified Clipped LMS Algorithm

    Directory of Open Access Journals (Sweden)

    Lotfizad Mojtaba

    2005-01-01

    Full Text Available Abstract A new algorithm is proposed for updating the weights of an adaptive filter. The proposed algorithm is a modification of an existing method, namely, the clipped LMS, and uses a three-level quantization ( scheme that involves the threshold clipping of the input signals in the filter weight update formula. Mathematical analysis shows the convergence of the filter weights to the optimum Wiener filter weights. Also, it can be proved that the proposed modified clipped LMS (MCLMS algorithm has better tracking than the LMS algorithm. In addition, this algorithm has reduced computational complexity relative to the unmodified one. By using a suitable threshold, it is possible to increase the tracking capability of the MCLMS algorithm compared to the LMS algorithm, but this causes slower convergence. Computer simulations confirm the mathematical analysis presented.

  2. Clip, connect, clone

    DEFF Research Database (Denmark)

    Fujima, Jun; Lunzer, Aran; Hornbæk, Kasper

    2010-01-01

    using three mechanisms: clipping of input and result elements from existing applications to form cells on a spreadsheet; connecting these cells using formulas, thus enabling result transfer between applications; and cloning cells so that multiple requests can be handled side by side. We demonstrate...

  3. Fuzzy expert systems using CLIPS

    Science.gov (United States)

    Le, Thach C.

    1994-01-01

    This paper describes a CLIPS-based fuzzy expert system development environment called FCLIPS and illustrates its application to the simulated cart-pole balancing problem. FCLIPS is a straightforward extension of CLIPS without any alteration to the CLIPS internal structures. It makes use of the object-oriented and module features in CLIPS version 6.0 for the implementation of fuzzy logic concepts. Systems of varying degrees of mixed Boolean and fuzzy rules can be implemented in CLIPS. Design and implementation issues of FCLIPS will also be discussed.

  4. Delay line clipping in a scintillation camera system

    International Nuclear Information System (INIS)

    Hatch, K.F.

    1979-01-01

    The present invention provides a novel base line restoring circuit and a novel delay line clipping circuit in a scintillation camera system. Single and double delay line clipped signal waveforms are generated for increasing the operational frequency and fidelity of data detection of the camera system by base line distortion such as undershooting, overshooting, and capacitive build-up. The camera system includes a set of photomultiplier tubes and associated amplifiers which generate sequences of pulses. These pulses are pulse-height analyzed for detecting a scintillation having an energy level which falls within a predetermined energy range. Data pulses are combined to provide coordinates and energy of photopeak events. The amplifiers are biassed out of saturation over all ranges of pulse energy level and count rate. Single delay line clipping circuitry is provided for narrowing the pulse width of the decaying electrical data pulses which increase operating speed without the occurrence of data loss. (JTA)

  5. Seismic signals hard clipping overcoming

    Science.gov (United States)

    Olszowa, Paula; Sokolowski, Jakub

    2018-01-01

    In signal processing the clipping is understand as the phenomenon of limiting the signal beyond certain threshold. It is often related to overloading of a sensor. Two particular types of clipping are being recognized: soft and hard. Beyond the limiting value soft clipping reduces the signal real gain while the hard clipping stiffly sets the signal values at the limit. In both cases certain amount of signal information is lost. Obviously if one possess the model which describes the considered signal and the threshold value (which might be slightly more difficult to obtain in the soft clipping case), the attempt of restoring the signal can be made. Commonly it is assumed that the seismic signals take form of an impulse response of some specific system. This may lead to belief that the sine wave may be the most appropriate to fit in the clipping period. However, this should be tested. In this paper the possibility of overcoming the hard clipping in seismic signals originating from a geoseismic station belonging to an underground mine is considered. A set of raw signals will be hard-clipped manually and then couple different functions will be fitted and compared in terms of least squares. The results will be then analysed.

  6. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph; Valdes, Francisco

    2017-02-14

    An exemplary mounting clip for removably attaching panels to a supporting structure comprises a base, spring locking clips, a lateral flange, a lever flange, and a spring bonding pad. The spring locking clips extend upwardly from the base. The lateral flange extends upwardly from a first side of the base. The lateral flange comprises a slot having an opening configured to receive at least a portion of one of the one or more panels. The lever flange extends outwardly from the lateral flange. The spring bonding flange extends downwardly from the lever flange. At least a portion of the first spring bonding flange comprises a serrated edge for gouging at least a portion of the one or more panels when the one or more panels are attached to the mounting clip to electrically and mechanically couple the one or more panels to the mounting clip.

  7. Concept of the central clip

    DEFF Research Database (Denmark)

    Alegria-Barrero, Eduardo; Chan, Pak Hei; Foin, Nicolas

    2014-01-01

    AIMS: Percutaneous edge-to-edge mitral valve repair with the MitraClip(®) was shown to be a safe and feasible alternative compared to conventional surgical mitral valve repair. We analyse the concept of the central clip and the predictors for the need of more than one MitraClip(®) in our high.......8±10.7 years (30 males, 13 females; mean logistic EuroSCORE 24.1±11, mean LVEF 47.5±18.5%; mean±SD) were treated. Median follow-up was 385 days (104-630; Q1-Q3). Device implantation success was 93%. All patients were treated following the central clip concept: 52.5% of MR was degenerative in aetiology and 47....... The presence of a restricted posterior mitral valve leaflet (PML) was inversely correlated with the need for more than one clip (p=0.02). A cut-off value of ≥7.5 mm for vena contracta predicted the need for a second clip (sensitivity 83%, specificity 90%, p=0.01). CONCLUSIONS: The central MitraClip(®) concept...

  8. Antarctic news clips - 1992

    Science.gov (United States)

    1992-07-01

    The newspaper and magazine stories selected for this book present only a sampling of one year's (July 1991 to July 1992) news coverage of Antarctica. The only requirement for inclusion in this publication is that the article's subject matter pertains or refers to Antarctica in some way - whether it is focused on the science done there, or on the people who play such a large part in the work accomplished, or on the issues related to it. No attempt has been made to correlate the number of articles, or their length, with the importance of the subjects treated. Clippings are provided to the Foundation by a service that searches for items containing the phrase 'National Science Foundation'. Identical versions of many stories, especially those written and distributed by wire services such as the Associated Press and United Press International, and by syndicated columnists, are published in numerous papers across the United States. Other articles are submitted from a variety of sources, including interested readers across the United States and in New Zealand.

  9. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph

    2017-07-11

    A photovoltaic panel mounting clip comprising a base, central indexing tabs, flanges, lateral indexing tabs, and vertical indexing tabs. The mounting clip removably attaches one or more panels to a beam or the like structure, both mechanically and electrically. It provides secure locking of the panels in all directions, while providing guidance in all directions for accurate installation of the panels to the beam or the like structure.

  10. Post-Vacuum-Assisted Stereotactic Core Biopsy Clip Displacement: A Comparison Between Commercially Available Clips and Surgical Clip.

    Science.gov (United States)

    Yen, Peggy; Dumas, Sandra; Albert, Arianne; Gordon, Paula

    2018-02-01

    The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. There was a significant difference in displacement among the clip types (P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the central clip and minimizes clip displacement. The same should apply to tomosynthesis-guided biopsy. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  11. Diagnostic applications of nail clippings.

    Science.gov (United States)

    Stephen, Sasha; Tosti, Antonella; Rubin, Adam I

    2015-04-01

    "Nail clipping is a simple technique for diagnosis of several nail unit dermatoses. This article summarizes the practical approach, utility, and histologic findings of a nail clipping in evaluation of onychomycosis, nail unit psoriasis, onychomatricoma, subungual hematoma, melanonychia, and nail cosmetics, and the forensic applications of this easily obtained specimen. It reviews important considerations in optimizing specimen collection, processing methods, and efficacy of special stains in several clinical contexts. Readers will develop a greater understanding and ease of application of this indispensable procedure in assessing nail unit dermatoses." Copyright © 2015 Elsevier Inc. All rights reserved.

  12. 21 CFR 882.4215 - Clip rack.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip rack. 882.4215 Section 882.4215 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4215 Clip rack. (a) Identification. A clip rack is a...

  13. Preserving Sharp Edges with Volume Clipping

    NARCIS (Netherlands)

    Termeer, M.A.; Oliván Bescós, J.; Telea, A.C.

    2006-01-01

    Volume clipping is a useful aid for exploring volumetric datasets. To maximize the effectiveness of this technique, the clipping geometry should be flexibly specified and the resulting images should not contain artifacts due to the clipping techniques. We present an improvement to an existing

  14. Adding run history to CLIPS

    Science.gov (United States)

    Tuttle, Sharon M.; Eick, Christoph F.

    1991-01-01

    To debug a C Language Integrated Production System (CLIPS) program, certain 'historical' information about a run is needed. It would be convenient for system builders to have the capability to request such information. We will discuss how historical Rete networks can be used for answering questions that help a system builder detect the cause of an error in a CLIPS program. Moreover, the cost of maintaining a historical Rete network is compared with that for a classical Rete network. We will demonstrate that the cost for assertions is only slightly higher for a historical Rete network. The cost for handling retraction could be significantly higher; however, we will show that by using special data structures that rely on hashing, it is also possible to implement retractions efficiently.

  15. 21 CFR 868.6225 - Nose clip.

    Science.gov (United States)

    2010-04-01

    ... ANESTHESIOLOGY DEVICES Miscellaneous § 868.6225 Nose clip. (a) Identification. A nose clip is a device intended to close a patient's external nares (nostrils) during diagnostic or therapeutic procedures. (b... from the current good manufacturing practice requirements of the quality system regulation in part 820...

  16. Chinese Language Video Clips. [CD-ROM].

    Science.gov (United States)

    Fleming, Stephen; Hipley, David; Ning, Cynthia

    This compact disc includes video clips covering six topics for the learner of Chinese: personal information, commercial transactions, travel and leisure, health and sports, food and school. Filmed on location in Beijing, these naturalistic video clips consist mainly of unrehearsed interviews of ordinary people. The learner is lead through a series…

  17. Sepsis from dropped clips at laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Hussain, Sarwat

    2001-01-01

    We report seven patients in whom five dropped surgical clips and two gallstones were visualized in the peritoneal cavity, on radiological studies. In two, subphrenic abscesses and empyemas developed as a result of dropped clips into the peritoneal cavity during or following laparoscopic cholecystectomy. In one of these two, a clip was removed surgically from the site of an abscess. In two other patients dropped gallstones, and in three, dropped clips led to no complications. These were seen incidentally on studies done for other indications. Abdominal abscess secondary to dropped gallstones is a well-recognized complication of laparoscopic cholecystectomy (LC). We conclude that even though dropped surgical clips usually do not cause problems, they should be considered as a risk additional to other well-known causes of post-LC abdominal sepsis

  18. Automated information retrieval using CLIPS

    Science.gov (United States)

    Raines, Rodney Doyle, III; Beug, James Lewis

    1991-01-01

    Expert systems have considerable potential to assist computer users in managing the large volume of information available to them. One possible use of an expert system is to model the information retrieval interests of a human user and then make recommendations to the user as to articles of interest. At Cal Poly, a prototype expert system written in the C Language Integrated Production System (CLIPS) serves as an Automated Information Retrieval System (AIRS). AIRS monitors a user's reading preferences, develops a profile of the user, and then evaluates items returned from the information base. When prompted by the user, AIRS returns a list of items of interest to the user. In order to minimize the impact on system resources, AIRS is designed to run in the background during periods of light system use.

  19. Intelligent tutoring using HyperCLIPS

    Science.gov (United States)

    Hill, Randall W., Jr.; Pickering, Brad

    1990-01-01

    HyperCard is a popular hypertext-like system used for building user interfaces to databases and other applications, and CLIPS is a highly portable government-owned expert system shell. We developed HyperCLIPS in order to fill a gap in the U.S. Army's computer-based instruction tool set; it was conceived as a development environment for building adaptive practical exercises for subject-matter problem-solving, though it is not limited to this approach to tutoring. Once HyperCLIPS was developed, we set out to implement a practical exercise prototype using HyperCLIPS in order to demonstrate the following concepts: learning can be facilitated by doing; student performance evaluation can be done in real-time; and the problems in a practical exercise can be adapted to the individual student's knowledge.

  20. SOCIOLINGUISTIC IMPORT OF NAME-CLIPPING AMONG ...

    African Journals Online (AJOL)

    NGOZI

    2013-02-27

    Feb 27, 2013 ... experiences which, most of the times, encompass cultural and philosophical ... The art of name clipping goes way back in language history ... describes Akan names as “iconic representation of complete social variables that ...

  1. Integrating CLIPS applications into heterogeneous distributed systems

    Science.gov (United States)

    Adler, Richard M.

    1991-01-01

    SOCIAL is an advanced, object-oriented development tool for integrating intelligent and conventional applications across heterogeneous hardware and software platforms. SOCIAL defines a family of 'wrapper' objects called agents, which incorporate predefined capabilities for distributed communication and control. Developers embed applications within agents and establish interactions between distributed agents via non-intrusive message-based interfaces. This paper describes a predefined SOCIAL agent that is specialized for integrating C Language Integrated Production System (CLIPS)-based applications. The agent's high-level Application Programming Interface supports bidirectional flow of data, knowledge, and commands to other agents, enabling CLIPS applications to initiate interactions autonomously, and respond to requests and results from heterogeneous remote systems. The design and operation of CLIPS agents are illustrated with two distributed applications that integrate CLIPS-based expert systems with other intelligent systems for isolating and mapping problems in the Space Shuttle Launch Processing System at the NASA Kennedy Space Center.

  2. Oscillator circuits

    CERN Document Server

    Graf, Rudolf F

    1996-01-01

    This series of circuits provides designers with a quick source for oscillator circuits. Why waste time paging through huge encyclopedias when you can choose the topic you need and select any of the specialized circuits sorted by application?This book in the series has 250-300 practical, ready-to-use circuit designs, with schematics and brief explanations of circuit operation. The original source for each circuit is listed in an appendix, making it easy to obtain additional information.Ready-to-use circuits.Grouped by application for easy look-up.Circuit source listing

  3. Measuring circuits

    CERN Document Server

    Graf, Rudolf F

    1996-01-01

    This series of circuits provides designers with a quick source for measuring circuits. Why waste time paging through huge encyclopedias when you can choose the topic you need and select any of the specialized circuits sorted by application?This book in the series has 250-300 practical, ready-to-use circuit designs, with schematics and brief explanations of circuit operation. The original source for each circuit is listed in an appendix, making it easy to obtain additional information.Ready-to-use circuits.Grouped by application for easy look-up.Circuit source listings

  4. Content-based video retrieval by example video clip

    Science.gov (United States)

    Dimitrova, Nevenka; Abdel-Mottaleb, Mohamed

    1997-01-01

    This paper presents a novel approach for video retrieval from a large archive of MPEG or Motion JPEG compressed video clips. We introduce a retrieval algorithm that takes a video clip as a query and searches the database for clips with similar contents. Video clips are characterized by a sequence of representative frame signatures, which are constructed from DC coefficients and motion information (`DC+M' signatures). The similarity between two video clips is determined by using their respective signatures. This method facilitates retrieval of clips for the purpose of video editing, broadcast news retrieval, or copyright violation detection.

  5. Photovoltaic module mounting clip with integral grounding

    Science.gov (United States)

    Lenox, Carl J.

    2010-08-24

    An electrically conductive mounting/grounding clip, usable with a photovoltaic (PV) assembly of the type having an electrically conductive frame, comprises an electrically conductive body. The body has a central portion and first and second spaced-apart arms extending from the central portion. Each arm has first and second outer portions with frame surface-disrupting element at the outer portions.

  6. 76 FR 42730 - Paper Clips From China

    Science.gov (United States)

    2011-07-19

    ... China Determination On the basis of the record \\1\\ developed in the subject five-year review, the United... China would be likely to lead to continuation or recurrence of material injury to an industry in the...), entitled Paper Clips from China: Investigation No. 731-TA-663 (Third Review). By order of the Commission...

  7. Semantic Labeling of Nonspeech Audio Clips

    Directory of Open Access Journals (Sweden)

    Xiaojuan Ma

    2010-01-01

    Full Text Available Human communication about entities and events is primarily linguistic in nature. While visual representations of information are shown to be highly effective as well, relatively little is known about the communicative power of auditory nonlinguistic representations. We created a collection of short nonlinguistic auditory clips encoding familiar human activities, objects, animals, natural phenomena, machinery, and social scenes. We presented these sounds to a broad spectrum of anonymous human workers using Amazon Mechanical Turk and collected verbal sound labels. We analyzed the human labels in terms of their lexical and semantic properties to ascertain that the audio clips do evoke the information suggested by their pre-defined captions. We then measured the agreement with the semantically compatible labels for each sound clip. Finally, we examined which kinds of entities and events, when captured by nonlinguistic acoustic clips, appear to be well-suited to elicit information for communication, and which ones are less discriminable. Our work is set against the broader goal of creating resources that facilitate communication for people with some types of language loss. Furthermore, our data should prove useful for future research in machine analysis/synthesis of audio, such as computational auditory scene analysis, and annotating/querying large collections of sound effects.

  8. A defect in the CLIP1 gene (CLIP-170) can cause autosomal recessive intellectual disability

    OpenAIRE

    Larti, Farzaneh; Kahrizi, Kimia; Musante, Luciana; Hu, Hao; Papari, Elahe; Fattahi, Zohreh; Bazazzadegan, Niloofar; Liu, Zhe; Banan, Mehdi; Garshasbi, Masoud; Wienker, Thomas F; Hilger Ropers, H; Galjart, Niels; Najmabadi, Hossein

    2015-01-01

    In the context of a comprehensive research project, investigating novel autosomal recessive intellectual disability (ARID) genes, linkage analysis based on autozygosity mapping helped identify an intellectual disability locus on Chr.12q24, in an Iranian family (LOD score=3.7). Next-generation sequencing (NGS) following exon enrichment in this novel interval, detected a nonsense mutation (p.Q1010*) in the CLIP1 gene. CLIP1 encodes a member of microtubule (MT) plus-end tracking proteins, which ...

  9. Biocompatibility of Plastic Clip in Neurocranium - Experimental Study on Dogs.

    Science.gov (United States)

    Delibegovic, Samir; Dizdarevic, Kemal; Cickusic, Elmir; Katica, Muhamed; Obhodjas, Muamer; Ocus, Muhamed

    2016-01-01

    A potential advantage of the use of the plastic clips in neurosurgery is their property of causing fewer artifacts than titanium clips as assessed by computed tomography and magnetic resonance scans. The biocompatibility of plastic clips was demonstrated in the peritoneal cavity, but their behavior in the neurocranium is not known. Twelve aggressive stray dogs designated for euthanasia were taken for this experimental study. The animals were divided into two groups. In all cases, after anesthesia, a craniotomy was performed, and after opening the dura, a proximal part titanium clip was placed on the isolated superficial Sylvian vein (a permanent Yasargil FT 746 T clip at a 90° angle, while a plastic Hem-o-lok clip ML was placed on another part of the vein). The first group of animals was sacrificed on the 7 th postoperative day and the second group on the 60 th postoperative day. Samples of tissue around the clips were taken for a histopathological evaluation. The plastic clip caused a more intensive tissue reaction than the titanium clip on the 7 th postoperative day, but there was no statistical difference. Even on the 60 th postoperative day there was no significant difference in tissue reaction between the titanium and plastic clips. These preliminary results confirm the possibility for the use of plastic clips in neurosurgery. Before their use in human neurosurgery, further studies are needed to investigate the long-term effects of the presence of plastic clips in the neurocranium, as well as studies of the aneurysmal model.

  10. 21 CFR 886.1410 - Ophthalmic trial lens clip.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens clip. 886.1410 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1410 Ophthalmic trial lens clip. (a) Identification. An ophthalmic trial lens clip is a device intended to hold prisms, spheres, cylinders, or...

  11. A defect in the CLIP1 gene (CLIP-170) can cause autosomal recessive intellectual disability.

    Science.gov (United States)

    Larti, Farzaneh; Kahrizi, Kimia; Musante, Luciana; Hu, Hao; Papari, Elahe; Fattahi, Zohreh; Bazazzadegan, Niloofar; Liu, Zhe; Banan, Mehdi; Garshasbi, Masoud; Wienker, Thomas F; Ropers, H Hilger; Galjart, Niels; Najmabadi, Hossein

    2015-03-01

    In the context of a comprehensive research project, investigating novel autosomal recessive intellectual disability (ARID) genes, linkage analysis based on autozygosity mapping helped identify an intellectual disability locus on Chr.12q24, in an Iranian family (LOD score = 3.7). Next-generation sequencing (NGS) following exon enrichment in this novel interval, detected a nonsense mutation (p.Q1010*) in the CLIP1 gene. CLIP1 encodes a member of microtubule (MT) plus-end tracking proteins, which specifically associates with the ends of growing MTs. These proteins regulate MT dynamic behavior and are important for MT-mediated transport over the length of axons and dendrites. As such, CLIP1 may have a role in neuronal development. We studied lymphoblastoid and skin fibroblast cell lines established from healthy and affected patients. RT-PCR and western blot analyses showed the absence of CLIP1 transcript and protein in lymphoblastoid cells derived from affected patients. Furthermore, immunofluorescence analyses showed MT plus-end staining only in fibroblasts containing the wild-type (and not the mutant) CLIP1 protein. Collectively, our data suggest that defects in CLIP1 may lead to ARID.

  12. Cortical Response Similarities Predict which Audiovisual Clips Individuals Viewed, but Are Unrelated to Clip Preference.

    Directory of Open Access Journals (Sweden)

    David A Bridwell

    Full Text Available Cortical responses to complex natural stimuli can be isolated by examining the relationship between neural measures obtained while multiple individuals view the same stimuli. These inter-subject correlation's (ISC's emerge from similarities in individual's cortical response to the shared audiovisual inputs, which may be related to their emergent cognitive and perceptual experience. Within the present study, our goal is to examine the utility of using ISC's for predicting which audiovisual clips individuals viewed, and to examine the relationship between neural responses to natural stimuli and subjective reports. The ability to predict which clips individuals viewed depends on the relationship of the EEG response across subjects and the nature in which this information is aggregated. We conceived of three approaches for aggregating responses, i.e. three assignment algorithms, which we evaluated in Experiment 1A. The aggregate correlations algorithm generated the highest assignment accuracy (70.83% chance = 33.33% and was selected as the assignment algorithm for the larger sample of individuals and clips within Experiment 1B. The overall assignment accuracy was 33.46% within Experiment 1B (chance = 06.25%, with accuracies ranging from 52.9% (Silver Linings Playbook to 11.75% (Seinfeld within individual clips. ISC's were significantly greater than zero for 15 out of 16 clips, and fluctuations within the delta frequency band (i.e. 0-4 Hz primarily contributed to response similarities across subjects. Interestingly, there was insufficient evidence to indicate that individuals with greater similarities in clip preference demonstrate greater similarities in cortical responses, suggesting a lack of association between ISC and clip preference. Overall these results demonstrate the utility of using ISC's for prediction, and further characterize the relationship between ISC magnitudes and subjective reports.

  13. Cortical Response Similarities Predict which Audiovisual Clips Individuals Viewed, but Are Unrelated to Clip Preference.

    Science.gov (United States)

    Bridwell, David A; Roth, Cullen; Gupta, Cota Navin; Calhoun, Vince D

    2015-01-01

    Cortical responses to complex natural stimuli can be isolated by examining the relationship between neural measures obtained while multiple individuals view the same stimuli. These inter-subject correlation's (ISC's) emerge from similarities in individual's cortical response to the shared audiovisual inputs, which may be related to their emergent cognitive and perceptual experience. Within the present study, our goal is to examine the utility of using ISC's for predicting which audiovisual clips individuals viewed, and to examine the relationship between neural responses to natural stimuli and subjective reports. The ability to predict which clips individuals viewed depends on the relationship of the EEG response across subjects and the nature in which this information is aggregated. We conceived of three approaches for aggregating responses, i.e. three assignment algorithms, which we evaluated in Experiment 1A. The aggregate correlations algorithm generated the highest assignment accuracy (70.83% chance = 33.33%) and was selected as the assignment algorithm for the larger sample of individuals and clips within Experiment 1B. The overall assignment accuracy was 33.46% within Experiment 1B (chance = 06.25%), with accuracies ranging from 52.9% (Silver Linings Playbook) to 11.75% (Seinfeld) within individual clips. ISC's were significantly greater than zero for 15 out of 16 clips, and fluctuations within the delta frequency band (i.e. 0-4 Hz) primarily contributed to response similarities across subjects. Interestingly, there was insufficient evidence to indicate that individuals with greater similarities in clip preference demonstrate greater similarities in cortical responses, suggesting a lack of association between ISC and clip preference. Overall these results demonstrate the utility of using ISC's for prediction, and further characterize the relationship between ISC magnitudes and subjective reports.

  14. Training model for cerebral aneurysm clipping

    Directory of Open Access Journals (Sweden)

    Hiroshi Tenjin, M.D., Ph.D.

    2017-12-01

    Full Text Available Clipping of cerebral aneurysms is still an important skill in neurosurgery. We have made a training model for the clipping of cerebral aneurysms. The concepts for the model were 1: training model for beginners, 2: three dimensional manipulation using an operating microscope, 3: the aneurysm model is to be perfused by simulated blood causing premature rupture. The correct relationship between each tissue, and softness of the brain and vessels were characteristics of the model. The skull, brain, arteries, and veins were made using a 3D printer with data from DICOM. The brain and vessels were made from polyvinyl alcohol (PVA. One training course was held and this model was useful for training of cerebral aneurysm surgery for young neurosurgeons.

  15. Modeling Timbre Similarity of Short Music Clips.

    Science.gov (United States)

    Siedenburg, Kai; Müllensiefen, Daniel

    2017-01-01

    There is evidence from a number of recent studies that most listeners are able to extract information related to song identity, emotion, or genre from music excerpts with durations in the range of tenths of seconds. Because of these very short durations, timbre as a multifaceted auditory attribute appears as a plausible candidate for the type of features that listeners make use of when processing short music excerpts. However, the importance of timbre in listening tasks that involve short excerpts has not yet been demonstrated empirically. Hence, the goal of this study was to develop a method that allows to explore to what degree similarity judgments of short music clips can be modeled with low-level acoustic features related to timbre. We utilized the similarity data from two large samples of participants: Sample I was obtained via an online survey, used 16 clips of 400 ms length, and contained responses of 137,339 participants. Sample II was collected in a lab environment, used 16 clips of 800 ms length, and contained responses from 648 participants. Our model used two sets of audio features which included commonly used timbre descriptors and the well-known Mel-frequency cepstral coefficients as well as their temporal derivates. In order to predict pairwise similarities, the resulting distances between clips in terms of their audio features were used as predictor variables with partial least-squares regression. We found that a sparse selection of three to seven features from both descriptor sets-mainly encoding the coarse shape of the spectrum as well as spectrotemporal variability-best predicted similarities across the two sets of sounds. Notably, the inclusion of non-acoustic predictors of musical genre and record release date allowed much better generalization performance and explained up to 50% of shared variance ( R 2 ) between observations and model predictions. Overall, the results of this study empirically demonstrate that both acoustic features related

  16. CLIP Tool Kit (CTK): a flexible and robust pipeline to analyze CLIP sequencing data.

    Science.gov (United States)

    Shah, Ankeeta; Qian, Yingzhi; Weyn-Vanhentenryck, Sebastien M; Zhang, Chaolin

    2017-02-15

    UV cross-linking and immunoprecipitation (CLIP), followed by high-throughput sequencing, is a powerful biochemical assay that maps in vivo protein-RNA interactions on a genome-wide scale. The CLIP Tool Kit (CTK) aims at providing a set of tools for flexible, streamlined and comprehensive CLIP data analysis. This software package extends the scope of our original CIMS package. The software is implemented in Perl. The source code and detailed documentation are available at http://zhanglab.c2b2.columbia.edu/index.php/CTK . cz2294@columbia.edu. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  17. Hardware Implementation Of Line Clipping A lgorithm By Using FPGA

    Directory of Open Access Journals (Sweden)

    Amar Dawod

    2013-04-01

    Full Text Available The computer graphics system performance is increasing faster than any other computing application. Algorithms for line clipping against convex polygons and lines have been studied for a long time and many research papers have been published so far. In spite of the latest graphical hardware development and significant increase of performance the clipping is still a bottleneck of any graphical system. So its implementation in hardware is essential for real time applications. In this paper clipping operation is discussed and a hardware implementation of the line clipping algorithm is presented and finally formulated and tested using Field Programmable Gate Arrays (FPGA. The designed hardware unit consists of two parts : the first is positional code generator unit and the second is the clipping unit. Finally it is worth mentioning that the  designed unit is capable of clipping (232524 line segments per second.       

  18. A CLIPS expert system for clinical flow cytometry data analysis

    Science.gov (United States)

    Salzman, G. C.; Duque, R. E.; Braylan, R. C.; Stewart, C. C.

    1990-01-01

    An expert system is being developed using CLIPS to assist clinicians in the analysis of multivariate flow cytometry data from cancer patients. Cluster analysis is used to find subpopulations representing various cell types in multiple datasets each consisting of four to five measurements on each of 5000 cells. CLIPS facts are derived from results of the clustering. CLIPS rules are based on the expertise of Drs. Stewart, Duque, and Braylan. The rules incorporate certainty factors based on case histories.

  19. Journal of Clipped Words in Reader's Digest Magazine

    OpenAIRE

    Simanjuntak, Lestari

    2012-01-01

    This study deals with Clipped Words in the “Laughter, the Best Medicine” of Reader's Digest. The objectives of the study are to find out the types of clipped words which are used in the “Laughter, the Best Medicine” of Reader's Digest, to find out sthe dominantly used in the whole story and to reason the dominant clipped word use in the text. The study use descriptive qualitative method. The data were collected from seventeen selected Reader's Digest which contains the clipped word by applie...

  20. Authoring Data-Driven Videos with DataClips.

    Science.gov (United States)

    Amini, Fereshteh; Riche, Nathalie Henry; Lee, Bongshin; Monroy-Hernandez, Andres; Irani, Pourang

    2017-01-01

    Data videos, or short data-driven motion graphics, are an increasingly popular medium for storytelling. However, creating data videos is difficult as it involves pulling together a unique combination of skills. We introduce DataClips, an authoring tool aimed at lowering the barriers to crafting data videos. DataClips allows non-experts to assemble data-driven "clips" together to form longer sequences. We constructed the library of data clips by analyzing the composition of over 70 data videos produced by reputable sources such as The New York Times and The Guardian. We demonstrate that DataClips can reproduce over 90% of our data videos corpus. We also report on a qualitative study comparing the authoring process and outcome achieved by (1) non-experts using DataClips, and (2) experts using Adobe Illustrator and After Effects to create data-driven clips. Results indicated that non-experts are able to learn and use DataClips with a short training period. In the span of one hour, they were able to produce more videos than experts using a professional editing tool, and their clips were rated similarly by an independent audience.

  1. An anthropomorphic phantom study of visualisation of surgical clips for partial breast irradiation (PBI) setup verification

    International Nuclear Information System (INIS)

    Thomas, Carys W.; Nichol, Alan M.; Park, Julie E.; Hui, Jason F.; Giddings, Alison A.; Grahame, Sheri; Otto, Karl

    2009-01-01

    Surgical clips were investigated for partial breast image-guided radiotherapy (IGRT). Small titanium clips were insufficiently well visualised. Medium tantalum clips were best for megavoltage IGRT and small tantalum clips were best for floor mounted kilovoltage IGRT (ExacTrac TM ). Both small tantalum and medium titanium clips were suitable for isocentric kilovoltage IGRT

  2. An anthropomorphic phantom study of visualisation of surgical clips for partial breast irradiation (PBI) setup verification.

    Science.gov (United States)

    Thomas, Carys W; Nichol, Alan M; Park, Julie E; Hui, Jason F; Giddings, Alison A; Grahame, Sheri; Otto, Karl

    2009-01-01

    Surgical clips were investigated for partial breast image-guided radiotherapy (IGRT). Small titanium clips were insufficiently well visualised. Medium tantalum clips were best for megavoltage IGRT and small tantalum clips were best for floor mounted kilovoltage IGRT (ExacTrac). Both small tantalum and medium titanium clips were suitable for isocentric kilovoltage IGRT.

  3. Resonance circuits for adiabatic circuits

    Directory of Open Access Journals (Sweden)

    C. Schlachta

    2003-01-01

    Full Text Available One of the possible techniques to reduces the power consumption in digital CMOS circuits is to slow down the charge transport. This slowdown can be achieved by introducing an inductor in the charging path. Additionally, the inductor can act as an energy storage element, conserving the energy that is normally dissipated during discharging. Together with the parasitic capacitances from the circuit a LCresonant circuit is formed.

  4. A novel vascular clip design for the reliable induction of 2-kidney, 1-clip hypertension in the rat

    OpenAIRE

    Chelko, Stephen P.; Schmiedt, Chad W.; Lewis, Tristan H.; Lewis, Stephen J.; Robertson, Tom P.

    2011-01-01

    The 2-kidney, 1-clip (2K1C) model has provided many insights into the pathogenesis of renovascular hypertension. However, studies using the 2K1C model often report low success rates of hypertension, with typical success rates of just 40–60%. We hypothesized that these low success rates are due to fundamental design flaws in the clips traditionally used in 2K1C models. Specifically, the gap widths of traditional silver clips may not be maintained during investigator handling and these clips ma...

  5. Recurrence of ICA-PCoA aneurysms after neck clipping.

    Science.gov (United States)

    Sakaki, T; Takeshima, T; Tominaga, M; Hashimoto, H; Kawaguchi, S

    1994-01-01

    Between 1975 and 1992, 2211 patients underwent aneurysmal neck clipping at the Nara Medical University clinic and associated hospitals. The aneurysm in 931 of these patients was situated at the junction of the internal carotid artery (ICA) and posterior communicating artery (PCoA). Seven patients were readmitted 4 to 17 years after the first surgery because of regrowth and rupture of an ICA-PCoA aneurysmal sac that had arisen from the residual neck. On angiograms obtained following aneurysmal neck clipping, a large primitive type of PCoA was demonstrated in six patients and a small PCoA in one. A small residual aneurysm was confirmed in only two patients and angiographically complete neck clipping in five. Recurrent ICA-PCoA aneurysms were separated into two types based on the position of the old clip in relation to the new growth. Type 1 aneurysms regrow from the entire neck and balloon eccentrically. In this type, it is possible to apply the clip at the neck as in conventional clipping for a ruptured aneurysm. Type 2 includes aneurysms in which the proximal portion of a previous clip is situated at the corner of the ICA and aneurysmal neck and the distal portion on the enlarged dome of the aneurysm, because the sac is regrowing from a portion of the residual neck. In this type of aneurysm, a Sugita fenestrated clip can occlude the residual neck, overriding the old clip. Classifying these aneurysms into two groups is very useful from a surgical point of view because it is possible to apply a new clip without removing the old clip, which was found to be adherent to surrounding tissue.

  6. Electronic circuit encyclopedia 2

    International Nuclear Information System (INIS)

    Park, Sun Ho

    1992-10-01

    This book is composed of 15 chapters, which are amplification of weak signal and measurement circuit audio control and power amplification circuit, data transmission and wireless system, forwarding and isolation, signal converting circuit, counter and comparator, discriminator circuit, oscillation circuit and synthesizer, digital and circuit on computer image processing circuit, sensor drive circuit temperature sensor circuit, magnetic control and application circuit, motor driver circuit, measuring instrument and check tool and power control and stability circuit.

  7. Electronic circuit encyclopedia 2

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sun Ho

    1992-10-15

    This book is composed of 15 chapters, which are amplification of weak signal and measurement circuit audio control and power amplification circuit, data transmission and wireless system, forwarding and isolation, signal converting circuit, counter and comparator, discriminator circuit, oscillation circuit and synthesizer, digital and circuit on computer image processing circuit, sensor drive circuit temperature sensor circuit, magnetic control and application circuit, motor driver circuit, measuring instrument and check tool and power control and stability circuit.

  8. Molecular clips based on propanediurea : synthesis and physical properties

    NARCIS (Netherlands)

    Jansen, Robertus Johannes

    2002-01-01

    This thesis describes the synthesis and physical properties of a series of molecular clips derived from the concave molecule propanediurea. These molecular clips are cavity-containing receptors that can bind a variety of aromatic guests. This binding is a result of hydrogen bonding and pi-pi

  9. The influence of clipping frequency on reserve carbohydrates and ...

    African Journals Online (AJOL)

    Increasing the frequency of clipping over a 12 week period resulted in decreasing root and stubble weight at the end of the 12 week period. During the regrowth period, following the clipping treatment, the aerial dry matter production was found to increase with the more lenient treatments. Keywords: weights|dry ...

  10. 21 CFR 886.3100 - Ophthalmic tantalum clip.

    Science.gov (United States)

    2010-04-01

    ... blood vessels in the eye. (b) Classification. Class II (special controls). The device is exempt from the...) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3100 Ophthalmic tantalum clip. (a) Identification. An ophthalmic tantalum clip is a malleable metallic device intended to be implanted permanently...

  11. Understanding and Applying Psychology through Use of News Clippings.

    Science.gov (United States)

    Rider, Elizabeth A.

    1992-01-01

    Discusses a student project for psychology courses in which students collect newspaper clippings that illustrate psychological concepts. Explains that the students record the source and write a brief description of the clipping, explaining how it relates to a psychological concept or theory. Includes results of student evaluations of the…

  12. 21 CFR 882.4190 - Clip forming/cutting instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip forming/cutting instrument. 882.4190 Section 882.4190 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES.../cutting instrument. (a) Identification. A clip forming/cutting instrument is a device used by the...

  13. Film clips and narrative text as subjective emotion elicitation techniques.

    Science.gov (United States)

    Zupan, Barbra; Babbage, Duncan R

    2017-01-01

    Film clips and narrative text are useful techniques in eliciting emotion in a laboratory setting but have not been examined side-by-side using the same methodology. This study examined the self-identification of emotions elicited by film clip and narrative text stimuli to confirm that selected stimuli appropriately target the intended emotions. Seventy participants viewed 30 film clips, and 40 additional participants read 30 narrative texts. Participants identified the emotion experienced (happy, sad, angry, fearful, neutral-six stimuli each). Eighty-five percent of participants self-identified the target emotion for at least two stimuli for all emotion categories of film clips, except angry (only one) and for all categories of narrative text, except fearful (only one). The most effective angry text was correctly identified 74% of the time. Film clips were more effective in eliciting all target emotions in participants for eliciting the correct emotion (angry), intensity rating (happy, sad), or both (fearful).

  14. Large window median filtering on Clip7

    Energy Technology Data Exchange (ETDEWEB)

    Mathews, K N

    1983-07-01

    Median filtering has been found to be a useful operation to perform on images in order to reduce random noise while preserving edges of objects. However, in some cases, as the resolution of the image increases, so too does the required window size of the filter. For parallel array processors, this leads to problems when dealing with the large amount of data involved. That is to say that there tend to be problems over slow access of data from pixels over a large neighbourhood, lack of available storage of this data during the operation and long computational times for finding the median. An algorithm for finding the median, designed for use on byte wide architecture parallel array processors is presented together with its implementation on Clip7, a scanning array of such processors. 6 references.

  15. Laparoscopic cholecystectomy without clips: 50 cases

    International Nuclear Information System (INIS)

    Morales Gonzalez, Raul A.; Goderich Lalan, Jose M.; Gonzalez Constanten, Juan

    2001-01-01

    A prospective and descriptive study that included 50 patients operated on of vesicular lithiasis by minimally invasive surgery and in whom the clips Were substituted by intra corporeal knots was conducted aimed at knowing the results of this procedure. These patients received attention at Celia Sanchez Manduley, Provincial Clinical and Surgical Teaching Hospital from April 12 to May 3, 2000. Aspects such as age, sex, surgical time, complications and hospital costs Were analyzed. The surgical time was 20 min higher than the one used in a by the usual technique. There Were no surgical complications. It was possible to reduce the cost of surgery. It is considered that this variable is safe, more economic and may be performed in a time similar to the one used in the usual technique

  16. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION)

    Science.gov (United States)

    Riley, G.

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh

  17. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (MACINTOSH VERSION)

    Science.gov (United States)

    Culbert, C.

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh

  18. Development of an artifact-free aneurysm clip

    Directory of Open Access Journals (Sweden)

    Brack Alexander

    2016-09-01

    Full Text Available For the treatment of intracranial aneurysms with aneurysm clips, usually a follow-up inspection in MRI is required. To avoid any artifacts, which can make a proper diagnosis difficult, a new approach for the manufacturing of an aneurysm clip entirely made from fiber-reinforced plastics has been developed. In this paper the concept for the design of the clip, the development of a new manufacturing technology for the fiber-reinforced components as well as first results from the examination of the components in phantom MRI testing is shown.

  19. Sympathetic block by metal clips may be a reversible operation

    DEFF Research Database (Denmark)

    Thomsen, Lars L; Mikkelsen, Rasmus T; Derejko, Miroslawa

    2014-01-01

    , but the question of reversibility remains controversial. Two recent experimental studies found severe histological signs of nerve damage 4-6 weeks after clip removal, but they only used conventional histopathological staining methods. METHODS: Thoracoscopic clipping of the sympathetic trunk was performed in adult...... the sympathetic chain vary tremendously. Most surgeons transect or resect the sympathetic chain, but application of a metal clip that blocks transmission of nerve impulses in the sympathetic chain is used increasingly worldwide. This approach offers potential reversibility if patients regret surgery...... suggests in theory that application of metal clips to the sympathetic chain is a reversible procedure if only the observation period is prolonged. Further studies with longer periods between application and removal as well as investigations of nerve conduction should be encouraged, because we do not know...

  20. Remission of migraine after clipping of saccular intracranial aneurysms

    DEFF Research Database (Denmark)

    Lebedeva, E R; Busygina, A V; Kolotvinov, V S

    2015-01-01

    interview. The remission rates of migraine and tension-type headache (TTH) in these patients were compared to 92 patients from a headache center. Diagnoses were made according to the ICHD-2. RESULTS: During 1 year preceding rupture 51 patients with SIA had migraine. During the year after clipping......BACKGROUND: Unruptured saccular intracranial aneurysm (SIA) is associated with an increased prevalence of migraine, but it is unclear whether this is altered by clipping of the aneurysm. The aim of our study was to determine whether remission rate of migraine and other recurrent headaches...... was greater in patients with SIA after clipping than in controls. METHODS: We prospectively studied 87 SIA patients with migraine or other recurrent headaches. They were interviewed about headaches in the preceding year before and 1 year after clipping using a validated semi-structured neurologist conducted...

  1. Ingested bread clip as an unexpected diagnostic tool.

    Science.gov (United States)

    Jay, Sharon M; Russell, Michael J; Lau, Yee C; Dunn, Joel W; Roberts, Ross

    2018-03-23

    We describe a case where a bread clip has in fact became lodged adjacent to a portion of small bowel affected by a deposit of previously undiagnosed metastatic serous carcinoma of likely ovarian origin.

  2. Clips supporting and spacing flanged sheets of reflective insulation

    International Nuclear Information System (INIS)

    Carr, R.W.

    1980-01-01

    This invention relates to clips, spacing and supporting flanged sheets of reflective insulation used to encase the main body and associated piping of nuclear reactors to minimize heat and radiation losses. (UK)

  3. Anesthesia management for MitraClip device implantation

    Directory of Open Access Journals (Sweden)

    Harikrishnan Kothandan

    2014-01-01

    Full Text Available Aims and Objectives: Percutaneous MitraClip implantation has been demonstrated as an alternative procedure in high-risk patients with symptomatic severe mitral regurgitation (MR who are not suitable (or denied mitral valve repair/replacement due to excessive co morbidity. The MitraClip implantation was performed under general anesthesia and with 3-dimensional transesophageal echocardiography (TEE and fluoroscopic guidance. Materials and Methods: Peri-operative patient data were extracted from the electronic and paper medical records of 21 patients who underwent MitraClip implantations. Results: Four MitraClip implantation were performed in the catheterization laboratory; remaining 17 were performed in the hybrid operating theatre. In 2 patients, procedure was aborted, in one due to migration of the Chiari network into the left atrium and in second one, the leaflets and chords of the mitral valve torn during clipping resulting in consideration for open surgery. In the remaining 19 patients, MitraClip was implanted and the patients showed acute reduction of severe MR to mild-moderate MR. All the patients had invasive blood pressure monitoring and the initial six patients had central venous catheterization prior to the procedure. Intravenous heparin was administered after the guiding catheter was introduced through the inter-atrial septum and activated clotting time was maintained beyond 250 s throughout the procedure. Protamine was administered at the end of the procedure. All the patients were monitored in the intensive care unit after the procedure. Conclusions: Percutaneous MitraClip implantation is a feasible alternative in high-risk patients with symptomatic severe MR. Anesthesia management requirements are similar to open surgical mitral valve repair or replacement. TEE plays a vital role during the MitraClip implantation.

  4. Controllable circuit

    DEFF Research Database (Denmark)

    2010-01-01

    A switch-mode power circuit comprises a controllable element and a control unit. The controllable element is configured to control a current in response to a control signal supplied to the controllable element. The control unit is connected to the controllable element and provides the control...

  5. Circuit Training.

    Science.gov (United States)

    Nelson, Jane B.

    1998-01-01

    Describes a research-based activity for high school physics students in which they build an LC circuit and find its resonant frequency of oscillation using an oscilloscope. Includes a diagram of the apparatus and an explanation of the procedures. (DDR)

  6. Como o clipping pode auxiliar o dermatologista How the Nail clipping helps the dermatologist

    Directory of Open Access Journals (Sweden)

    José Fillus Neto

    2009-04-01

    Full Text Available Alterações ungueais são queixas muito frequentes nos consultórios dermatológicos. Onicomicoses representam cerca de 50% das onicopatias, daí a importância de se estabelecer o diagnóstico correto antes de se iniciar o tratamento. Neste artigo, relataremos a utilidade de um exame que é de fácil execução pelo clínico, de baixo custo e sensível: esse exame consiste na análise histopatológica da queratina ungueal distal, atualmente já consagrado com o termo clipping.Onycodystrophies are common problems in dermatologic practice. About 50% of dystrophic nails have a fungal cause, so it is very important to establish a correct diagnosis before treatment. In this article we relate the usefulness of an easydoing exam, free from pain, cheap and sensible. This exam is the histopathology of the nail keratin or nail clipping.

  7. A novel vascular clip design for the reliable induction of 2-kidney, 1-clip hypertension in the rat.

    Science.gov (United States)

    Chelko, Stephen P; Schmiedt, Chad W; Lewis, Tristan H; Lewis, Stephen J; Robertson, Tom P

    2012-02-01

    The 2-kidney, 1-clip (2K1C) model has provided many insights into the pathogenesis of renovascular hypertension. However, studies using the 2K1C model often report low success rates of hypertension, with typical success rates of just 40-60%. We hypothesized that these low success rates are due to fundamental design flaws in the clips traditionally used in 2K1C models. Specifically, the gap widths of traditional silver clips may not be maintained during investigator handling and these clips may also be easily dislodged from the renal artery following placement. Therefore, we designed and tested a novel vascular clip possessing design features to maintain both gap width and position around the renal artery. In this initial study, application of these new clips to the left renal artery produced reliable and consistent levels of hypertension in rats. Nine-day application of clips with gap widths of 0.27, 0.25, and 0.23 mm elicited higher mean arterial blood pressures of 112 ± 4, 121 ± 6, and 135 ± 7 mmHg, respectively (n = 8 for each group), than those of sham-operated controls (95 ± 2 mmHg, n = 8). Moreover, 8 out of 8 rats in each of the 0.23 and 0.25 mm 2K1C groups were hypertensive, whereas 7 out of 8 rats in the 0.27 mm 2K1C group were hypertensive. Plasma renin concentrations were also increased in all 2K1C groups compared with sham-operated controls. In summary, this novel clip design may help eliminate the large degree of unreliability commonly encountered with the 2K1C model.

  8. Knowledge base rule partitioning design for CLIPS

    Science.gov (United States)

    Mainardi, Joseph D.; Szatkowski, G. P.

    1990-01-01

    This describes a knowledge base (KB) partitioning approach to solve the problem of real-time performance using the CLIPS AI shell when containing large numbers of rules and facts. This work is funded under the joint USAF/NASA Advanced Launch System (ALS) Program as applied research in expert systems to perform vehicle checkout for real-time controller and diagnostic monitoring tasks. The Expert System advanced development project (ADP-2302) main objective is to provide robust systems responding to new data frames of 0.1 to 1.0 second intervals. The intelligent system control must be performed within the specified real-time window, in order to meet the demands of the given application. Partitioning the KB reduces the complexity of the inferencing Rete net at any given time. This reduced complexity improves performance but without undo impacts during load and unload cycles. The second objective is to produce highly reliable intelligent systems. This requires simple and automated approaches to the KB verification & validation task. Partitioning the KB reduces rule interaction complexity overall. Reduced interaction simplifies the V&V testing necessary by focusing attention only on individual areas of interest. Many systems require a robustness that involves a large number of rules, most of which are mutually exclusive under different phases or conditions. The ideal solution is to control the knowledge base by loading rules that directly apply for that condition, while stripping out all rules and facts that are not used during that cycle. The practical approach is to cluster rules and facts into associated 'blocks'. A simple approach has been designed to control the addition and deletion of 'blocks' of rules and facts, while allowing real-time operations to run freely. Timing tests for real-time performance for specific machines under R/T operating systems have not been completed but are planned as part of the analysis process to validate the design.

  9. Digital video clips for improved pedagogy and illustration of scientific research — with illustrative video clips on atomic spectrometry

    Science.gov (United States)

    Michel, Robert G.; Cavallari, Jennifer M.; Znamenskaia, Elena; Yang, Karl X.; Sun, Tao; Bent, Gary

    1999-12-01

    This article is an electronic publication in Spectrochimica Acta Electronica (SAE), a section of Spectrochimica Acta Part B (SAB). The hardcopy text is accompanied by an electronic archive, stored on the CD-ROM accompanying this issue. The archive contains video clips. The main article discusses the scientific aspects of the subject and explains the purpose of the video files. Short, 15-30 s, digital video clips are easily controllable at the computer keyboard, which gives a speaker the ability to show fine details through the use of slow motion. Also, they are easily accessed from the computer hard drive for rapid extemporaneous presentation. In addition, they are easily transferred to the Internet for dissemination. From a pedagogical point of view, the act of making a video clip by a student allows for development of powers of observation, while the availability of the technology to make digital video clips gives a teacher the flexibility to demonstrate scientific concepts that would otherwise have to be done as 'live' demonstrations, with all the likely attendant misadventures. Our experience with digital video clips has been through their use in computer-based presentations by undergraduate and graduate students in analytical chemistry classes, and by high school and middle school teachers and their students in a variety of science and non-science classes. In physics teaching laboratories, we have used the hardware to capture digital video clips of dynamic processes, such as projectiles and pendulums, for later mathematical analysis.

  10. ART/Ada and CLIPS/Ada

    Science.gov (United States)

    Culbert, Chris

    1990-01-01

    Although they have reached a point of commercial viability, expert systems were originally developed in artificial intelligence (AI) research environments. Many of the available tools still work best in such environments. These environments typically utilize special hardware such as LISP machines and relatively unfamiliar languages such as LISP or Prolog. Space Station applications will require deep integration of expert system technology with applications developed in conventional languages, specifically Ada. The ability to apply automation to Space Station functions could be greatly enhanced by widespread availability of state-of-the-art expert system tools based on Ada. Although there have been some efforts to examine the use of Ada for AI applications, there are few, if any, existing products which provide state-of-the-art AI capabilities in an Ada tool. The goal of the ART/Ada Design Project is to conduct research into the implementation in Ada of state-of-the-art hybrid expert systems building tools (ESBT's). This project takes the following approach: using the existing design of the ART-IM ESBT as a starting point, analyze the impact of the Ada language and Ada development methodologies on that design; redesign the system in Ada; and analyze its performance. The research project will attempt to achieve a comprehensive understanding of the potential for embedding expert systems in Ada systems for eventual application in future Space Station Freedom projects. During Phase 1 of the project, initial requirements analysis, design, and implementation of the kernel subset of ART-IM functionality was completed. During Phase 2, the effort has been focused on the implementation and performance analysis of several versions with increasing functionality. Since production quality ART/Ada tools will not be available for a considerable time, and additional subtask of this project will be the completion of an Ada version of the CLIPS expert system shell developed by NASA

  11. Hemodynamic response during aneurysm clipping surgery among experienced neurosurgeons.

    Science.gov (United States)

    Bunevicius, Adomas; Bilskiene, Diana; Macas, Andrius; Tamasauskas, Arimantas

    2016-02-01

    Neurosurgery is a challenging field associated with high levels of mental stress. The goal of this study was to investigate the hemodynamic response of experienced neurosurgeons during aneurysm clipping surgery and to evaluate whether neurosurgeons' hemodynamic responses are associated with patients' clinical statuses. Four vascular neurosurgeons (all male; mean age 51 ± 10 years; post-residency experience ≥7 years) were studied during 42 aneurysm clipping procedures. Blood pressure (BP) and heart rate (HR) were assessed at rest and during seven phases of surgery: before the skin incision, after craniotomy, after dural opening, after aneurysm neck dissection, after aneurysm clipping, after dural closure and after skin closure. HR and BP were significantly greater during surgery relative to the rest situation (p ≤ 0.03). There was a statistically significant increase in neurosurgeons' HR (F [6, 41] = 10.88, p neurosurgeon experience, the difference in BP as a function of aneurysm rupture was not significant (p > 0.08). Aneurysm location, intraoperative aneurysm rupture, admission WFNS score, admission Glasgow Coma Scale scores and Fisher grade were not associated with neurosurgeons' intraoperative HR and BP (all p > 0.07). Aneurysm clipping surgery is associated with significant hemodynamic system activation among experienced neurosurgeons. The greatest HR and BP were after aneurysm neck dissection and clipping. Aneurysm location and patient clinical status were not associated with intraoperative changes of neurosurgeons' HR and BP.

  12. Speed Biases With Real-Life Video Clips

    Directory of Open Access Journals (Sweden)

    Federica Rossi

    2018-03-01

    Full Text Available We live almost literally immersed in an artificial visual world, especially motion pictures. In this exploratory study, we asked whether the best speed for reproducing a video is its original, shooting speed. By using adjustment and double staircase methods, we examined speed biases in viewing real-life video clips in three experiments, and assessed their robustness by manipulating visual and auditory factors. With the tested stimuli (short clips of human motion, mixed human-physical motion, physical motion and ego-motion, speed underestimation was the rule rather than the exception, although it depended largely on clip content, ranging on average from 2% (ego-motion to 32% (physical motion. Manipulating display size or adding arbitrary soundtracks did not modify these speed biases. Estimated speed was not correlated with estimated duration of these same video clips. These results indicate that the sense of speed for real-life video clips can be systematically biased, independently of the impression of elapsed time. Measuring subjective visual tempo may integrate traditional methods that assess time perception: speed biases may be exploited to develop a simple, objective test of reality flow, to be used for example in clinical and developmental contexts. From the perspective of video media, measuring speed biases may help to optimize video reproduction speed and validate “natural” video compression techniques based on sub-threshold temporal squeezing.

  13. Clinical experience of titanium cerebral aneurysm clips. Evaluation of artifact of CT and MRI

    International Nuclear Information System (INIS)

    Ninomiya, Takashi; Kato, Yoko; Sano, Hirotoshi

    1996-01-01

    The titanium aneurysm clips manufactured by AESCULAP Company are expected to be useful, not only for clinical applications, but also for reducing artifacts in post-operative CT and MRI. We carried out an investigation of the behavior of the new Yasargil titanium clips in a 1.5T MR imager. The new titanium clips showed considerably smaller clip-induced MR and CT artifacts than phynox and elgiloy clips. No movement of the titanium clips was seen by introducing them to the MR imager. Subsequent to these experimental studies, we applied titanium clips to 25 cerebral aneurysms. Post-operative CT, especially helical scanning CT and MR showed minimal artifacts, leading to the conclusion that the titanium clips are better than the other types of clips for the evaluation of post-operative neuroradiological images. (author)

  14. Low Proteolytic Clipping of Histone H3 in Cervical Cancer

    Science.gov (United States)

    Sandoval-Basilio, Jorge; Serafín-Higuera, Nicolás; Reyes-Hernandez, Octavio D.; Serafín-Higuera, Idanya; Leija-Montoya, Gabriela; Blanco-Morales, Magali; Sierra-Martínez, Monica; Ramos-Mondragon, Roberto; García, Silvia; López-Hernández, Luz Berenice; Yocupicio-Monroy, Martha; Alcaraz-Estrada, Sofia L.

    2016-01-01

    Chromatin in cervical cancer (CC) undergoes chemical and structural changes that alter the expression pattern of genes. Recently, a potential mechanism, which regulates gene expression at transcriptional levels is the proteolytic clipping of histone H3. However, until now this process in CC has not been reported. Using HeLa cells as a model of CC and human samples from patients with CC, we identify that the H3 cleavage was lower in CC compared with control tissue. Additionally, the histone H3 clipping was performed by serine and aspartyl proteases in HeLa cells. These results suggest that histone H3 clipping operates as part of post-translational modification system in CC. PMID:27698925

  15. PAPR Reduction of FBMC by Clipping and Its Iterative Compensation

    Directory of Open Access Journals (Sweden)

    Zsolt Kollár

    2012-01-01

    Full Text Available Physical layers of communication systems using Filter Bank Multicarrier (FBMC as a modulation scheme provide low out-of-band leakage but suffer from the large Peak-to-Average Power Ratio (PAPR of the transmitted signal. Two special FBMC schemes are investigated in this paper: the Orthogonal Frequency Division Multiplexing (OFDM and the Staggered Multitone (SMT. To reduce the PAPR of the signal, time domain clipping is applied in both schemes. If the clipping is not compensated, the system performance is severely affected. To avoid this degradation, an iterative noise cancelation technique, Bussgang Noise Cancelation (BNC, is applied in the receiver. It is shown that clipping can be a good means for reducing the PAPR, especially for the SMT scheme. A novel modified BNC receiver is presented for SMT. It is shown how this technique can be implemented in real-life applications where special requirements must be met regarding the spectral characteristics of the transmitted signal.

  16. LOGIC CIRCUIT

    Science.gov (United States)

    Strong, G.H.; Faught, M.L.

    1963-12-24

    A device for safety rod counting in a nuclear reactor is described. A Wheatstone bridge circuit is adapted to prevent de-energizing the hopper coils of a ball backup system if safety rods, sufficient in total control effect, properly enter the reactor core to effect shut down. A plurality of resistances form one arm of the bridge, each resistance being associated with a particular safety rod and weighted in value according to the control effect of the particular safety rod. Switching means are used to switch each of the resistances in and out of the bridge circuit responsive to the presence of a particular safety rod in its effective position in the reactor core and responsive to the attainment of a predetermined velocity by a particular safety rod enroute to its effective position. The bridge is unbalanced in one direction during normal reactor operation prior to the generation of a scram signal and the switching means and resistances are adapted to unbalance the bridge in the opposite direction if the safety rods produce a predetermined amount of control effect in response to the scram signal. The bridge unbalance reversal is then utilized to prevent the actuation of the ball backup system, or, conversely, a failure of the safety rods to produce the predetermined effect produces no unbalance reversal and the ball backup system is actuated. (AEC)

  17. GaAs circuit restructuring by multi-level laser-direct-written tungsten process

    International Nuclear Information System (INIS)

    Black, J.G.; Doran, S.P.; Rothschild, M.; Sedlacek, J.H.C.; Ehrlich, D.J.

    1987-01-01

    Laser-direct-writing processes are employed to fabricate a GaAs digital integrated circuit. The lithography-free techniques deposit and etch conductors and resistors, and remove insulating layers, thus enabling multilevel interconnections. These combined direct-write processes provide the flexibility of clip-lead prototyping on a micrometer scale

  18. Clip reconstruction of a large right MCA bifurcation aneurysm. Case report

    Directory of Open Access Journals (Sweden)

    Giovani A.

    2014-06-01

    Full Text Available We report a case of complex large middle cerebral artery (MCA bifurcation aneurysm that ruptured during dissection from the very adherent MCA branches but was successfully clipped and the MCA bifurcation reconstructed using 4 Yasargill clips. Through a right pterional craniotomy the sylvian fissure was largely opened as to allow enough workspace for clipping the aneurysm and placing a temporary clip on M1. The pacient recovered very well after surgery and was discharged after 1 week with no neurological deficit. Complex MCA bifurcation aneurysms can be safely reconstructed using regular clips, without the need of using fenestrated clips or complex by-pass procedures.

  19. Short- circuit tests of circuit breakers

    OpenAIRE

    Chorovský, P.

    2015-01-01

    This paper deals with short-circuit tests of low voltage electrical devices. In the first part of this paper, there are described basic types of short- circuit tests and their principles. Direct and indirect (synthetic) tests with more details are described in the second part. Each test and principles are explained separately. Oscilogram is obtained from short-circuit tests of circuit breakers at laboratory. The aim of this research work is to propose a test circuit for performing indirect test.

  20. YUCSA: A CLIPS expert database system to monitor academic performance

    Science.gov (United States)

    Toptsis, Anestis A.; Ho, Frankie; Leindekar, Milton; Foon, Debra Low; Carbonaro, Mike

    1991-01-01

    The York University CLIPS Student Administrator (YUCSA), an expert database system implemented in C Language Integrated Processing System (CLIPS), for monitoring the academic performance of undergraduate students at York University, is discussed. The expert system component in the system has already been implemented for two major departments, and it is under testing and enhancement for more departments. Also, more elaborate user interfaces are under development. We describe the design and implementation of the system, problems encountered, and immediate future plans. The system has excellent maintainability and it is very efficient, taking less than one minute to complete an assessment of one student.

  1. Collective of mechatronics circuit

    International Nuclear Information System (INIS)

    1987-02-01

    This book is composed of three parts, which deals with mechatronics system about sensor, circuit and motor. The contents of the first part are photo sensor of collector for output, locating detection circuit with photo interrupts, photo sensor circuit with CdS cell and lamp, interface circuit with logic and LED and temperature sensor circuit. The second part deals with oscillation circuit with crystal, C-R oscillation circuit, F-V converter, timer circuit, stability power circuit, DC amp and DC-DC converter. The last part is comprised of bridge server circuit, deformation bridge server, controlling circuit of DC motor, controlling circuit with IC for PLL and driver circuit of stepping motor and driver circuit of Brushless.

  2. Collective of mechatronics circuit

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1987-02-15

    This book is composed of three parts, which deals with mechatronics system about sensor, circuit and motor. The contents of the first part are photo sensor of collector for output, locating detection circuit with photo interrupts, photo sensor circuit with CdS cell and lamp, interface circuit with logic and LED and temperature sensor circuit. The second part deals with oscillation circuit with crystal, C-R oscillation circuit, F-V converter, timer circuit, stability power circuit, DC amp and DC-DC converter. The last part is comprised of bridge server circuit, deformation bridge server, controlling circuit of DC motor, controlling circuit with IC for PLL and driver circuit of stepping motor and driver circuit of Brushless.

  3. A model-based approach to identify binding sites in CLIP-Seq data.

    Directory of Open Access Journals (Sweden)

    Tao Wang

    Full Text Available Cross-linking immunoprecipitation coupled with high-throughput sequencing (CLIP-Seq has made it possible to identify the targeting sites of RNA-binding proteins in various cell culture systems and tissue types on a genome-wide scale. Here we present a novel model-based approach (MiClip to identify high-confidence protein-RNA binding sites from CLIP-seq datasets. This approach assigns a probability score for each potential binding site to help prioritize subsequent validation experiments. The MiClip algorithm has been tested in both HITS-CLIP and PAR-CLIP datasets. In the HITS-CLIP dataset, the signal/noise ratios of miRNA seed motif enrichment produced by the MiClip approach are between 17% and 301% higher than those by the ad hoc method for the top 10 most enriched miRNAs. In the PAR-CLIP dataset, the MiClip approach can identify ∼50% more validated binding targets than the original ad hoc method and two recently published methods. To facilitate the application of the algorithm, we have released an R package, MiClip (http://cran.r-project.org/web/packages/MiClip/index.html, and a public web-based graphical user interface software (http://galaxy.qbrc.org/tool_runner?tool_id=mi_clip for customized analysis.

  4. Circuit parties.

    Science.gov (United States)

    Guzman, R

    2000-03-01

    Circuit parties are extended celebrations, lasting from a day to a week, primarily attended by gay and bisexual men in their thirties and forties. These large-scale dance parties move from city to city and draw thousands of participants. The risks for contracting HIV during these parties include recreational drug use and unsafe sex. Limited data exists on the level of risk at these parties, and participants are skeptical of outside help because of past criticism of these events. Health care and HIV advocates can promote risk-reduction strategies with the cooperation of party planners and can counsel individuals to personally reduce their own risk. To convey the message, HIV prevention workers should emphasize positive and community-centered aspects of the parties, such as taking care of friends and avoiding overdose.

  5. 76 FR 26242 - Paper Clips From the People's Republic of China: Final Results of Expedited Sunset Review of...

    Science.gov (United States)

    2011-05-06

    ... order are plastic and vinyl covered paper clips, butterfly clips, binder clips, or other paper fasteners... order is revoked. Parties can obtain a public copy of the I&D Memo from the Central Records Unit, room...

  6. Receiver-based recovery of clipped ofdm signals for papr reduction: A bayesian approach

    KAUST Repository

    Ali, Anum; Al-Rabah, Abdullatif R.; Masood, Mudassir; Al-Naffouri, Tareq Y.

    2014-01-01

    at the receiver for information restoration. In this paper, we acknowledge the sparse nature of the clipping signal and propose a low-complexity Bayesian clipping estimation scheme. The proposed scheme utilizes a priori information about the sparsity rate

  7. Commutation circuit for an HVDC circuit breaker

    Science.gov (United States)

    Premerlani, William J.

    1981-01-01

    A commutation circuit for a high voltage DC circuit breaker incorporates a resistor capacitor combination and a charging circuit connected to the main breaker, such that a commutating capacitor is discharged in opposition to the load current to force the current in an arc after breaker opening to zero to facilitate arc interruption. In a particular embodiment, a normally open commutating circuit is connected across the contacts of a main DC circuit breaker to absorb the inductive system energy trapped by breaker opening and to limit recovery voltages to a level tolerable by the commutating circuit components.

  8. Direct mounted photovoltaic device with improved front clip

    Science.gov (United States)

    Keenihan, James R; Boven, Michelle; Brown, Jr., Claude; Gaston, Ryan S; Hus, Michael; Langmaid, Joe A; Lesniak, Mike

    2013-11-05

    The present invention is premised upon a photovoltaic assembly system for securing and/or aligning at least a plurality of vertically adjacent (overlapping) photovoltaic device assemblies to one another. The securing function being accomplished by a clip member that may be a separate component or integral to one or more of the photovoltaic device assemblies.

  9. Direct mounted photovoltaic device with improved side clip

    Science.gov (United States)

    Keenihan, James R; Boven, Michelle L; Brown, Jr., Claude; Eurich, Gerald K; Gaston, Ryan S; Hus, Michael

    2013-11-19

    The present invention is premised upon a photovoltaic assembly system for securing and/or aligning at least a plurality of vertically adjacent photovoltaic device assemblies to one another. The securing function being accomplished by a clip member that may be a separate component or integral to one or more of the photovoltaic device assemblies.

  10. ASTP 15th Anniversary Clip-Media Release

    Science.gov (United States)

    1990-01-01

    This release is comprised of 5 separate clips, including the following: CL 762 Astronauts/Cosmonauts Visit to KSC and Walt Disney World; CL 739 ASTP Joint Crew Activities; CL 748 ASTP Astronauts/Cosmonauts Horlock Ranch Visit; CL 758 T-21 ASTP Training - US/USSR; and CL 743 ASTP Joint Crew Training in the Soviet Union.

  11. Improving NAVFAC's total quality management of construction drawings with CLIPS

    Science.gov (United States)

    Antelman, Albert

    1991-01-01

    A diagnostic expert system to improve the quality of Naval Facilities Engineering Command (NAVFAC) construction drawings and specification is described. C Language Integrated Production System (CLIPS) and computer aided design layering standards are used in an expert system to check and coordinate construction drawings and specifications to eliminate errors and omissions.

  12. Sociolinguistic import of name-clipping among Omambala cultural ...

    African Journals Online (AJOL)

    This study examines the perceived but obvious manifestation of name-clipping among Omambala cultural zone of Anambra State. This situation has given rise to distortion of names and most often, to either mis-interpretation or complete loss of the original and full meanings of the names. This situation of misinterpretation is ...

  13. Equation-Method for correcting clipping errors in OFDM signals.

    Science.gov (United States)

    Bibi, Nargis; Kleerekoper, Anthony; Muhammad, Nazeer; Cheetham, Barry

    2016-01-01

    Orthogonal frequency division multiplexing (OFDM) is the digital modulation technique used by 4G and many other wireless communication systems. OFDM signals have significant amplitude fluctuations resulting in high peak to average power ratios which can make an OFDM transmitter susceptible to non-linear distortion produced by its high power amplifiers (HPA). A simple and popular solution to this problem is to clip the peaks before an OFDM signal is applied to the HPA but this causes in-band distortion and introduces bit-errors at the receiver. In this paper we discuss a novel technique, which we call the Equation-Method, for correcting these errors. The Equation-Method uses the Fast Fourier Transform to create a set of simultaneous equations which, when solved, return the amplitudes of the peaks before they were clipped. We show analytically and through simulations that this method can, correct all clipping errors over a wide range of clipping thresholds. We show that numerical instability can be avoided and new techniques are needed to enable the receiver to differentiate between correctly and incorrectly received frequency-domain constellation symbols.

  14. Our History Clips: Collaborating for the Common Good

    Science.gov (United States)

    Bailey, Beatrice N.

    2017-01-01

    This case study reveals how middle school social studies teachers within a professional development program are encouraging their students to use multiple disciplinary literacies to create Our History Clips as they also work toward developing a classroom community of engaged student citizens.

  15. 33 CFR 183.532 - Clips, straps, and hose clamps.

    Science.gov (United States)

    2010-07-01

    ... resistant material; and (2) Not cut or abrade the fuel line. (b) If tested in accordance with the fire test under § 183.590, a hose clamp installed on a fuel line system requiring metallic fuel lines or “USCG... (CONTINUED) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.532 Clips...

  16. An Exploration of Gender Bias in Computer Clip Art.

    Science.gov (United States)

    Dyrud, Marilyn A.

    1997-01-01

    Examines over 14,000 clip art images for gender bias. Finds that only 4% of images depicted women and that those images present women in stereotypical roles, such as secretaries, nurses, teachers. Notes the irony that communication instructors expend much effort persuading students that gender-free prose is the new model--while visually still…

  17. Extravasal occlusion of large vessels with titanic clips: efficiency, indications, and contraindications.

    Science.gov (United States)

    Vasilenko, Yu V; Kim, A I; Kotov, S A

    2002-11-01

    The mechanism of extravasal occlusion of blood vessels with titanic clips "Atrauclip" and "Ligaclip extra" was studied in order to reveal indications and contraindications to their use. Occlusion with the clips of both types was ineffective in vessels with a diameter of >7.0 mm. Arteritis or the presence of an intravascular occlusion facility in the vessel were also the contraindications for clip occlusion. In overcases the procedure of occlusion with titanic clips was efficient and atraumatic.

  18. Effect of apical meristem clipping on carbon allocation and morphological development of white oak seedlings

    Science.gov (United States)

    Paul P. Kormanik; Shi-Jean S. Sung; T.L. Kormanik; Stanley J. Zarnoch

    1994-01-01

    Seedlings from three open-pollinated half-sib white oak seedlots were clipped in mid-July and their development was compared to nonclipped controls after one growing season.In general when data were analyzed by family, clipped seedlings were significantly less desirable in three to six of the eight variables tested.Numerically, in all families seedlots, the clipped...

  19. Current MitraClip experience, safety and feasibility in the Netherlands

    NARCIS (Netherlands)

    Rahhab, Z.; Kortlandt, F. A.; Velu, J. F.; Schurer, R. A. J.; Delgado, V.; Tonino, P.; Boven, A. J.; van den Branden, B. J. L.; Kraaijeveld, A. O.; Voskuil, M.; Hoorntje, J.; van Wely, M. [=Marleen; van Houwelingen, K.; Bleeker, G. B.; Rensing, B.; Kardys, I.; Baan, J.; van der Heyden, J. A. S.; van Mieghem, N. M.

    2017-01-01

    Purpose Data on MitraClip procedural safety and efficacy in the Netherlands are scarce. We aim to provide an overview of the Dutch MitraClip experience. Methods We pooled anonymised demographic and procedural data of 1151 consecutive MitraClip patients, from 13 Dutch hospitals. Data was collected by

  20. Analog circuit design designing dynamic circuit response

    CERN Document Server

    Feucht, Dennis

    2010-01-01

    This second volume, Designing Dynamic Circuit Response builds upon the first volume Designing Amplifier Circuits by extending coverage to include reactances and their time- and frequency-related behavioral consequences.

  1. Trigger circuit

    International Nuclear Information System (INIS)

    Verity, P.R.; Chaplain, M.D.; Turner, G.D.J.

    1984-01-01

    A monostable trigger circuit comprises transistors TR2 and TR3 arranged with their collectors and bases interconnected. The collector of the transistor TR2 is connected to the base of transistor TR3 via a capacitor C2 the main current path of a grounded base transistor TR1 and resistive means R2,R3. The collector of transistor TR3 is connected to the base of transistor TR2 via resistive means R6, R7. In the stable state all the transistors are OFF, the capacitor C2 is charged, and the output is LOW. A positive pulse input to the base of TR2 switches it ON, which in turn lowers the voltage at points A and B and so switches TR1 ON so that C2 can discharge via R2, R3, which in turn switches TR3 ON making the output high. Thus all three transistors are latched ON. When C2 has discharged sufficiently TR1 switches OFF, followed by TR3 (making the output low again) and TR2. The components C1, C3 and R4 serve to reduce noise, and the diode D1 is optional. (author)

  2. Efficient computation of clipped Voronoi diagram for mesh generation

    KAUST Repository

    Yan, Dongming

    2013-04-01

    The Voronoi diagram is a fundamental geometric structure widely used in various fields, especially in computer graphics and geometry computing. For a set of points in a compact domain (i.e. a bounded and closed 2D region or a 3D volume), some Voronoi cells of their Voronoi diagram are infinite or partially outside of the domain, but in practice only the parts of the cells inside the domain are needed, as when computing the centroidal Voronoi tessellation. Such a Voronoi diagram confined to a compact domain is called a clipped Voronoi diagram. We present an efficient algorithm to compute the clipped Voronoi diagram for a set of sites with respect to a compact 2D region or a 3D volume. We also apply the proposed method to optimal mesh generation based on the centroidal Voronoi tessellation. Crown Copyright © 2011 Published by Elsevier Ltd. All rights reserved.

  3. Efficient computation of clipped Voronoi diagram for mesh generation

    KAUST Repository

    Yan, Dongming; Wang, Wen Ping; Lé vy, Bruno L.; Liu, Yang

    2013-01-01

    The Voronoi diagram is a fundamental geometric structure widely used in various fields, especially in computer graphics and geometry computing. For a set of points in a compact domain (i.e. a bounded and closed 2D region or a 3D volume), some Voronoi cells of their Voronoi diagram are infinite or partially outside of the domain, but in practice only the parts of the cells inside the domain are needed, as when computing the centroidal Voronoi tessellation. Such a Voronoi diagram confined to a compact domain is called a clipped Voronoi diagram. We present an efficient algorithm to compute the clipped Voronoi diagram for a set of sites with respect to a compact 2D region or a 3D volume. We also apply the proposed method to optimal mesh generation based on the centroidal Voronoi tessellation. Crown Copyright © 2011 Published by Elsevier Ltd. All rights reserved.

  4. A Sieving ANN for Emotion-Based Movie Clip Classification

    Science.gov (United States)

    Watanapa, Saowaluk C.; Thipakorn, Bundit; Charoenkitkarn, Nipon

    Effective classification and analysis of semantic contents are very important for the content-based indexing and retrieval of video database. Our research attempts to classify movie clips into three groups of commonly elicited emotions, namely excitement, joy and sadness, based on a set of abstract-level semantic features extracted from the film sequence. In particular, these features consist of six visual and audio measures grounded on the artistic film theories. A unique sieving-structured neural network is proposed to be the classifying model due to its robustness. The performance of the proposed model is tested with 101 movie clips excerpted from 24 award-winning and well-known Hollywood feature films. The experimental result of 97.8% correct classification rate, measured against the collected human-judges, indicates the great potential of using abstract-level semantic features as an engineered tool for the application of video-content retrieval/indexing.

  5. Esophageal Perforation due to Transesophageal Echocardiogram: New Endoscopic Clip Treatment

    Directory of Open Access Journals (Sweden)

    John Robotis

    2014-07-01

    Full Text Available Esophageal perforation due to transesophageal echocardiogram (TEE during cardiac surgery is rare. A 72-year-old female underwent TEE during an operation for aortic valve replacement. Further, the patient presented hematemesis. Gastroscopy revealed an esophageal bleeding ulcer. Endoscopic therapy was successful. Although a CT scan excluded perforation, the patient became febrile, and a second gastroscopy revealed a big perforation at the site of ulcer. The patient's clinical condition required endoscopic intervention with a new OTSC® clip (Ovesco Endoscopy, Tübingen, Germany. The perforation was successfully sealed. The patient remained on intravenous antibiotics, proton pump inhibitors and parenteral nutrition for few days, followed by enteral feeding. She was discharged fully recovered 3 months later. We clearly demonstrate an effective, less invasive treatment of an esophageal perforation with a new endoscopic clip.

  6. Functional outcome of microsurgical clipping compared to endovascular coiling.

    Science.gov (United States)

    Premananda, R M; Ramesh, N; Hillol, K P

    2012-12-01

    Endovascular coiling has been used increasingly as an alternative to neurosurgical clipping for treating subarachnoid hemorrhage secondary to aneurysm rupture. In a retrospective cohort review on the treatment methods of aneurysm rupture in Hospital Kuala Lumpur over the period of five years (2005-2009) a total of 268 patients were treated. These patients were broadly categorized into two groups based on their treatment mode for ruptured aneurysms. Statistical analysis was determined using Chi- Square tests to study these associations. In our study, 67.5% of patients presented with Good World Federation of Neurosurgical Societies (WFNS) grade (WFNS1-2) while 32.5% patients presented with Poor WFNS prior to intervention. In our outcome, it was noted that 60.4% had good functional outcome (mRS grade 0-2) as compared to 39.6% patients who had poor mRS(modified rankin scale) outcome (mRS 3-6). In the good WFNS group, 76% of patients in clipping group had a good mRS outcome while, 86.5% patients in coiling group had good mRS outcome (p=0.114). In poor WFNS presentation, it was noted that in 77.3% patients in clipping group, had poor mRS outcome. Similarly with poor WFNS presentation, 83.3% of patient in coiling group had poor outcome. (p=1.00). Hence when we control the WFNS group, there was no significant association between treatment group (clipping and coiling) and mRS outcome at 6 months. The outcome of patient is determined by initial clinical presentation (WFNS grade) and influenced by requirement of Extraventricular drain (EVD) in presence of hydrocephalus, CSF infection and pneumonia. Therefore the decision regarding treatment option needs to be individualized based on the presentation of the patient.

  7. Solid-state circuits

    CERN Document Server

    Pridham, G J

    2013-01-01

    Solid-State Circuits provides an introduction to the theory and practice underlying solid-state circuits, laying particular emphasis on field effect transistors and integrated circuits. Topics range from construction and characteristics of semiconductor devices to rectification and power supplies, low-frequency amplifiers, sine- and square-wave oscillators, and high-frequency effects and circuits. Black-box equivalent circuits of bipolar transistors, physical equivalent circuits of bipolar transistors, and equivalent circuits of field effect transistors are also covered. This volume is divided

  8. Circuit analysis for dummies

    CERN Document Server

    Santiago, John

    2013-01-01

    Circuits overloaded from electric circuit analysis? Many universities require that students pursuing a degree in electrical or computer engineering take an Electric Circuit Analysis course to determine who will ""make the cut"" and continue in the degree program. Circuit Analysis For Dummies will help these students to better understand electric circuit analysis by presenting the information in an effective and straightforward manner. Circuit Analysis For Dummies gives you clear-cut information about the topics covered in an electric circuit analysis courses to help

  9. Determination of moulting events in rock lobsters from pleopod clipping.

    Science.gov (United States)

    Gardner, Caleb; Mills, David J

    2013-01-01

    Rock lobster growth is routinely measured for research to optimise management measures such as size limits and quotas. The process of estimating growth is complicated in crustaceans as growth only occurs when the animal moults. As data are typically collected by tag-recapture methods, the timing of moulting events can bias results. For example, if annual moulting events take place within a very short time-at-large after tagging, or if time-at-large is long and no moulting occurs. Classifying data into cases where moulting has / has not occurred during time-at-large can be required and can generally be determined by change in size between release and recapture. However, in old or slow growth individuals the moult increment can be too small to provide surety that moulting has occurred. A method that has been used since the 1970's to determine moulting in rock lobsters involves clipping the distal portion of a pleopod so that any regeneration observed at recapture can be used as evidence of a moult. We examined the use of this method in both tank and long-duration field trials within a marine protected area, which provided access to large animals with smaller growth increments. Our results emphasised that determination of moulting by change in size was unreliable with larger lobsters and that pleopod clipping can assist in identifying moulting events. However, regeneration was an unreliable measure of moulting if clipping occurred less than three months before the moult.

  10. Determination of moulting events in rock lobsters from pleopod clipping.

    Directory of Open Access Journals (Sweden)

    Caleb Gardner

    Full Text Available Rock lobster growth is routinely measured for research to optimise management measures such as size limits and quotas. The process of estimating growth is complicated in crustaceans as growth only occurs when the animal moults. As data are typically collected by tag-recapture methods, the timing of moulting events can bias results. For example, if annual moulting events take place within a very short time-at-large after tagging, or if time-at-large is long and no moulting occurs. Classifying data into cases where moulting has / has not occurred during time-at-large can be required and can generally be determined by change in size between release and recapture. However, in old or slow growth individuals the moult increment can be too small to provide surety that moulting has occurred. A method that has been used since the 1970's to determine moulting in rock lobsters involves clipping the distal portion of a pleopod so that any regeneration observed at recapture can be used as evidence of a moult. We examined the use of this method in both tank and long-duration field trials within a marine protected area, which provided access to large animals with smaller growth increments. Our results emphasised that determination of moulting by change in size was unreliable with larger lobsters and that pleopod clipping can assist in identifying moulting events. However, regeneration was an unreliable measure of moulting if clipping occurred less than three months before the moult.

  11. Object oriented development of engineering software using CLIPS

    Science.gov (United States)

    Yoon, C. John

    1991-01-01

    Engineering applications involve numeric complexity and manipulations of a large amount of data. Traditionally, numeric computation has been the concern in developing an engineering software. As engineering application software became larger and more complex, management of resources such as data, rather than the numeric complexity, has become the major software design problem. Object oriented design and implementation methodologies can improve the reliability, flexibility, and maintainability of the resulting software; however, some tasks are better solved with the traditional procedural paradigm. The C Language Integrated Production System (CLIPS), with deffunction and defgeneric constructs, supports the procedural paradigm. The natural blending of object oriented and procedural paradigms has been cited as the reason for the popularity of the C++ language. The CLIPS Object Oriented Language's (COOL) object oriented features are more versatile than C++'s. A software design methodology based on object oriented and procedural approaches appropriate for engineering software, and to be implemented in CLIPS was outlined. A method for sensor placement for Space Station Freedom is being implemented in COOL as a sample problem.

  12. Current limiter circuit system

    Science.gov (United States)

    Witcher, Joseph Brandon; Bredemann, Michael V.

    2017-09-05

    An apparatus comprising a steady state sensing circuit, a switching circuit, and a detection circuit. The steady state sensing circuit is connected to a first, a second and a third node. The first node is connected to a first device, the second node is connected to a second device, and the steady state sensing circuit causes a scaled current to flow at the third node. The scaled current is proportional to a voltage difference between the first and second node. The switching circuit limits an amount of current that flows between the first and second device. The detection circuit is connected to the third node and the switching circuit. The detection circuit monitors the scaled current at the third node and controls the switching circuit to limit the amount of the current that flows between the first and second device when the scaled current is greater than a desired level.

  13. 76 FR 44575 - Paper Clips From the People's Republic of China: Continuation of the Antidumping Duty Order

    Science.gov (United States)

    2011-07-26

    ..., butterfly clips, binder clips, or other paper fasteners that are not made wholly of wire of base metal and... DEPARTMENT OF COMMERCE International Trade Administration [A-570-826] Paper Clips From the People... the antidumping duty order on paper clips from the People's Republic of China (``PRC'') would likely...

  14. Sex Differences in Emotional Evaluation of Film Clips: Interaction with Five High Arousal Emotional Categories

    Science.gov (United States)

    Maffei, Antonio; Vencato, Valentina; Angrilli, Alessandro

    2015-01-01

    The present study aimed to investigate gender differences in the emotional evaluation of 18 film clips divided into six categories: Erotic, Scenery, Neutral, Sadness, Compassion, and Fear. 41 female and 40 male students rated all clips for valence-pleasantness, arousal, level of elicited distress, anxiety, jittery feelings, excitation, and embarrassment. Analysis of positive films revealed higher levels of arousal, pleasantness, and excitation to the Scenery clips in both genders, but lower pleasantness and greater embarrassment in women compared to men to Erotic clips. Concerning unpleasant stimuli, unlike men, women reported more unpleasantness to the Compassion, Sadness, and Fear compared to the Neutral clips and rated them also as more arousing than did men. They further differentiated the films by perceiving greater arousal to Fear than to Compassion clips. Women rated the Sadness and Fear clips with greater Distress and Jittery feelings than men did. Correlation analysis between arousal and the other emotional scales revealed that, although men looked less aroused than women to all unpleasant clips, they also showed a larger variance in their emotional responses as indicated by the high number of correlations and their relatively greater extent, an outcome pointing to a masked larger sensitivity of part of male sample to emotional clips. We propose a new perspective in which gender difference in emotional responses can be better evidenced by means of film clips selected and clustered in more homogeneous categories, controlled for arousal levels, as well as evaluated through a number of emotion focused adjectives. PMID:26717488

  15. Receiver-based recovery of clipped ofdm signals for papr reduction: A bayesian approach

    KAUST Repository

    Ali, Anum

    2014-01-01

    Clipping is one of the simplest peak-to-average power ratio reduction schemes for orthogonal frequency division multiplexing (OFDM). Deliberately clipping the transmission signal degrades system performance, and clipping mitigation is required at the receiver for information restoration. In this paper, we acknowledge the sparse nature of the clipping signal and propose a low-complexity Bayesian clipping estimation scheme. The proposed scheme utilizes a priori information about the sparsity rate and noise variance for enhanced recovery. At the same time, the proposed scheme is robust against inaccurate estimates of the clipping signal statistics. The undistorted phase property of the clipped signal, as well as the clipping likelihood, is utilized for enhanced reconstruction. Furthermore, motivated by the nature of modern OFDM-based communication systems, we extend our clipping reconstruction approach to multiple antenna receivers and multi-user OFDM.We also address the problem of channel estimation from pilots contaminated by the clipping distortion. Numerical findings are presented that depict favorable results for the proposed scheme compared to the established sparse reconstruction schemes.

  16. Sex Differences in Emotional Evaluation of Film Clips: Interaction with Five High Arousal Emotional Categories.

    Directory of Open Access Journals (Sweden)

    Antonio Maffei

    Full Text Available The present study aimed to investigate gender differences in the emotional evaluation of 18 film clips divided into six categories: Erotic, Scenery, Neutral, Sadness, Compassion, and Fear. 41 female and 40 male students rated all clips for valence-pleasantness, arousal, level of elicited distress, anxiety, jittery feelings, excitation, and embarrassment. Analysis of positive films revealed higher levels of arousal, pleasantness, and excitation to the Scenery clips in both genders, but lower pleasantness and greater embarrassment in women compared to men to Erotic clips. Concerning unpleasant stimuli, unlike men, women reported more unpleasantness to the Compassion, Sadness, and Fear compared to the Neutral clips and rated them also as more arousing than did men. They further differentiated the films by perceiving greater arousal to Fear than to Compassion clips. Women rated the Sadness and Fear clips with greater Distress and Jittery feelings than men did. Correlation analysis between arousal and the other emotional scales revealed that, although men looked less aroused than women to all unpleasant clips, they also showed a larger variance in their emotional responses as indicated by the high number of correlations and their relatively greater extent, an outcome pointing to a masked larger sensitivity of part of male sample to emotional clips. We propose a new perspective in which gender difference in emotional responses can be better evidenced by means of film clips selected and clustered in more homogeneous categories, controlled for arousal levels, as well as evaluated through a number of emotion focused adjectives.

  17. Intuitive analog circuit design

    CERN Document Server

    Thompson, Marc

    2013-01-01

    Intuitive Analog Circuit Design outlines ways of thinking about analog circuits and systems that let you develop a feel for what a good, working analog circuit design should be. This book reflects author Marc Thompson's 30 years of experience designing analog and power electronics circuits and teaching graduate-level analog circuit design, and is the ideal reference for anyone who needs a straightforward introduction to the subject. In this book, Dr. Thompson describes intuitive and ""back-of-the-envelope"" techniques for designing and analyzing analog circuits, including transistor amplifi

  18. The circuit designer's companion

    CERN Document Server

    Williams, Tim

    1991-01-01

    The Circuit Designer's Companion covers the theoretical aspects and practices in analogue and digital circuit design. Electronic circuit design involves designing a circuit that will fulfill its specified function and designing the same circuit so that every production model of it will fulfill its specified function, and no other undesired and unspecified function.This book is composed of nine chapters and starts with a review of the concept of grounding, wiring, and printed circuits. The subsequent chapters deal with the passive and active components of circuitry design. These topics are foll

  19. Electronic devices and circuits

    CERN Document Server

    Pridham, Gordon John

    1972-01-01

    Electronic Devices and Circuits, Volume 3 provides a comprehensive account on electronic devices and circuits and includes introductory network theory and physics. The physics of semiconductor devices is described, along with field effect transistors, small-signal equivalent circuits of bipolar transistors, and integrated circuits. Linear and non-linear circuits as well as logic circuits are also considered. This volume is comprised of 12 chapters and begins with an analysis of the use of Laplace transforms for analysis of filter networks, followed by a discussion on the physical properties of

  20. Percutaneous interventional mitral regurgitation treatment using the Mitra-Clip system

    DEFF Research Database (Denmark)

    Boekstegers, P; Hausleiter, J; Baldus, S

    2014-01-01

    The interventional treatment of mitral valve regurgitation by the MitraClip procedure has grown rapidly in Germany and Europe during the past years. The MitraClip procedure has the potential to treat high-risk patients with secondary mitral valve regurgitation and poor left ventricular function....... Furthermore, patients with primary mitral valve regurgitation may be treated successfully by the MitraClip procedure in case of high surgical risk or in very old patients. At the same time it has been emphasised that the MitraClip interventional treatment is still at an early stage of clinical development....... The largest clinical experience with the MitraClip procedure so far is probably present in some German cardiovascular centers, which here summarise their recommendations on the current indications and procedural steps of the MitraClip treatment. These recommendations of the AGIK and ALKK may present a basis...

  1. Musical molecules: the molecular junction as an active component in audio distortion circuits

    Science.gov (United States)

    Bergren, Adam Johan; Zeer-Wanklyn, Lucas; Semple, Mitchell; Pekas, Nikola; Szeto, Bryan; McCreery, Richard L.

    2016-03-01

    Molecular junctions that have a non-linear current-voltage characteristic consistent with quantum mechanical tunneling are demonstrated as analog audio clipping elements in overdrive circuits widely used in electronic music, particularly with electric guitars. The performance of large-area molecular junctions fabricated at the wafer level is compared to currently standard semiconductor diode clippers, showing a difference in the sound character. The harmonic distributions resulting from the use of traditional and molecular clipping elements are reported and discussed, and differences in performance are noted that result from the underlying physics that controls the electronic properties of each clipping component. In addition, the ability to tune the sound using the molecular junction is demonstrated. Finally, the hybrid circuit is compared to an overdriven tube amplifier, which has been the standard reference electric guitar clipped tone for over 60 years. In order to investigate the feasibility of manufacturing molecular junctions for use in commercial applications, devices are fabricated using a low-density format at the wafer level, where 38 dies per wafer, each containing two molecular junctions, are made with exceptional non-shorted yield (99.4%, representing 718 out of 722 tested devices) without requiring clean room facilities.

  2. Musical molecules: the molecular junction as an active component in audio distortion circuits

    International Nuclear Information System (INIS)

    Bergren, Adam Johan; Zeer-Wanklyn, Lucas; Pekas, Nikola; Szeto, Bryan; McCreery, Richard L; Semple, Mitchell

    2016-01-01

    Molecular junctions that have a non-linear current–voltage characteristic consistent with quantum mechanical tunneling are demonstrated as analog audio clipping elements in overdrive circuits widely used in electronic music, particularly with electric guitars. The performance of large-area molecular junctions fabricated at the wafer level is compared to currently standard semiconductor diode clippers, showing a difference in the sound character. The harmonic distributions resulting from the use of traditional and molecular clipping elements are reported and discussed, and differences in performance are noted that result from the underlying physics that controls the electronic properties of each clipping component. In addition, the ability to tune the sound using the molecular junction is demonstrated. Finally, the hybrid circuit is compared to an overdriven tube amplifier, which has been the standard reference electric guitar clipped tone for over 60 years. In order to investigate the feasibility of manufacturing molecular junctions for use in commercial applications, devices are fabricated using a low-density format at the wafer level, where 38 dies per wafer, each containing two molecular junctions, are made with exceptional non-shorted yield (99.4%, representing 718 out of 722 tested devices) without requiring clean room facilities. (paper)

  3. CLIPS based decision support system for water distribution networks

    Directory of Open Access Journals (Sweden)

    K. Sandeep

    2011-10-01

    Full Text Available The difficulty in knowledge representation of a water distribution network (WDN problem has contributed to the limited use of artificial intelligence (AI based expert systems (ES in the management of these networks. This paper presents a design of a Decision Support System (DSS that facilitates "on-demand'' knowledge generation by utilizing results of simulation runs of a suitably calibrated and validated hydraulic model of an existing aged WDN corresponding to emergent or even hypothetical but likely scenarios. The DSS augments the capability of a conventional expert system by integrating together the hydraulic modelling features with heuristics based knowledge of experts under a common, rules based, expert shell named CLIPS (C Language Integrated Production System. In contrast to previous ES, the knowledge base of the DSS has been designed to be dynamic by superimposing CLIPS on Structured Query Language (SQL. The proposed ES has an inbuilt calibration module that enables calibration of an existing (aged WDN for the unknown, and unobservable, Hazen-Williams C-values. In addition, the daily run and simulation modules of the proposed ES further enable the CLIPS inference engine to evaluate the network performance for any emergent or suggested test scenarios. An additional feature of the proposed design is that the DSS integrates computational platforms such as MATLAB, open source Geographical Information System (GIS, and a relational database management system (RDBMS working under the umbrella of the Microsoft Visual Studio based common user interface. The paper also discusses implementation of the proposed framework on a case study and clearly demonstrates the utility of the application as an able aide for effective management of the study network.

  4. Clinical features and nail clippings in 52 children with psoriasis.

    Science.gov (United States)

    Uber, Marjorie; Carvalho, Vânia O; Abagge, Kerstin T; Robl Imoto, Renata; Werner, Betina

    2018-03-01

    Nail clipping, the act of cutting the distal portion of a nail for microscopic analysis, can complement the diagnosis of skin diseases with nail involvement, such as psoriasis. This study aimed to describe histopathologic findings on 81 nails from 52 children and adolescents with skin psoriasis and to determine whether these changes correlated with the severity of skin and nail involvement. Children with psoriasis were enrolled in this cross-sectional study to obtain Psoriasis Area and Severity Index (PASI) and Nail Psoriasis Severity Index (NAPSI) scores. The most altered nails were processed using periodic acid-Schiff with diastase staining. Fifty-two patients with a median age of 10.5 years were included. The median Nail Psoriasis Severity Index score of the 20 nails from these patients was 17 (range 3-80). The most common findings were pitting (94.2%), leukonychia (73.0%), and longitudinal ridges (63.5%). Eighty-one nail fragments were collected by clipping. Neutrophils were found in 6 samples (7.6%) and serous lakes in 15 (19%). Median nail plate thickness was 0.3 mm (range 0.1-0.63 mm). Patients whose nails had neutrophils had a higher median PASI score (6.1 vs 2.0, P = .03). Patients whose nails had serous lakes had higher median PASI (5.3 vs 1.9, P = .008) and NAPSI (median 45.0 vs 18.0, P = .006) scores. There seems to be a correlation between some microscopic nail features in children with psoriasis and their PASI and NAPSI scores, so nail clippings from children with suspected psoriasis may help with diagnosis, especially in the presence of neutrophils, and in excluding onychomycosis. © 2018 Wiley Periodicals, Inc.

  5. Current MitraClip experience, safety and feasibility in the Netherlands

    OpenAIRE

    Rahhab, Z.; Kortlandt, F.A.; Velu, J.F.; Schurer, R.A.J.; Delgado, V.; Tonino, P.; Boven, A.J. van; Branden, B.J.L. Van den; Kraaijeveld, A.O.; Voskuil, M.; Hoorntje, J.; Wely, M.H. van; Houwelingen, K. van; Bleeker, G.B.; Rensing, B.

    2017-01-01

    PURPOSE: Data on MitraClip procedural safety and efficacy in the Netherlands are scarce. We aim to provide an overview of the Dutch MitraClip experience. METHODS: We pooled anonymised demographic and procedural data of 1151 consecutive MitraClip patients, from 13 Dutch hospitals. Data was collected by product specialists in collaboration with local operators. Effect on mitral regurgitation was intra-procedurally assessed by transoesophageal echocardiography. Technical success and device succe...

  6. Electrical Circuits and Water Analogies

    Science.gov (United States)

    Smith, Frederick A.; Wilson, Jerry D.

    1974-01-01

    Briefly describes water analogies for electrical circuits and presents plans for the construction of apparatus to demonstrate these analogies. Demonstrations include series circuits, parallel circuits, and capacitors. (GS)

  7. CLIPS/Ada: An Ada-based tool for building expert systems

    Science.gov (United States)

    White, W. A.

    1990-01-01

    Clips/Ada is a production system language and a development environment. It is functionally equivalent to the CLIPS tool. CLIPS/Ada was developed in order to provide a means of incorporating expert system technology into projects where the use of the Ada language had been mandated. A secondary purpose was to glean information about the Ada language and its compilers. Specifically, whether or not the language and compilers were mature enough to support AI applications. The CLIPS/Ada tool is coded entirely in Ada and is designed to be used by Ada systems that require expert reasoning.

  8. A method of handing down surgical clipping technique for cerebral aneurysm

    International Nuclear Information System (INIS)

    Idei, Masaru; Yamane, Kanji; Okita, Shinji; Kumano, Kiyoshi; Nakae, Ryuta

    2009-01-01

    Meticulous clipping techniques are essential to obtain good results. Recently, the introduction of intravascular surgery for cerebral aneurysms has decreased the number of the direct clipping surgeries. And the increasing number of the lawsuits against doctors further discourages young surgeons from attempting clipping. As a result, young neurosurgeons, have less experience performing clipping. Therefore, we must learn clipping techniques from expert neurosurgeons under the limitation of having fewer opportunities to perform clipping surgery. In this paper, I present my experiences and discuss ways to obtain techniques for clipping surgery. I performed surgical clipping in 19 cases, 12 unruptured and 7 ruptured aneurysms, 7 males and 12 females aged from 36 to 79 years old (mean 61.9 years). Postoperatively, there were no symptomatic complications, but there were 2 asymptomatic infarctions that were revealed on CT scan. Intraoperative premature rupture occurred in 1 patient with a ruptured aneurysm. Techniques of manipulation with micro-forceps, suction and spatula are required for successful clipping. Off-the-job training of dissecting chicken wing arteries and rat abdominal aortas and vena cavas is useful. Moreover, actual experiences of surgical operations are essential. Surgical experiences raise the motivation of young neurosurgeons and encourage them to train more. We believe that this benign cycle contributes to meticulous surgical skills. (author)

  9. A systematic review of discomfort due to toe or ear clipping in laboratory rodents

    Science.gov (United States)

    Geessink, Florentine J.; Brouwer, Michelle A. E.; Tillema, Alice; Ritskes-Hoitinga, Merel

    2017-01-01

    Toe clipping and ear clipping (also ear notching or ear punching) are frequently used methods for individual identification of laboratory rodents. These procedures potentially cause severe discomfort, which can reduce animal welfare and distort experimental results. However, no systematic summary of the evidence on this topic currently exists. We conducted a systematic review of the evidence for discomfort due to toe or ear clipping in rodents. The review methodology was pre-specified in a registered review protocol. The population, intervention, control, outcome (PICO) question was: In rodents, what is the effect of toe clipping or ear clipping, compared with no clipping or sham clipping, on welfare-related outcomes? Through a systematic search in PubMed, Embase, Web of Science and grey literature, we identified seven studies on the effect of ear clipping on animal welfare, and five such studies on toe clipping. Studies were included in the review if they contained original data from an in vivo experiment in rodents, assessing the effect of toe clipping or ear clipping on a welfare-related outcome. Case studies and studies applying unsuitable co-interventions were excluded. Study quality was appraised using an extended version of SYstematic Review Centre for Laboratory animal Experimentation (SYRCLE)’s risk of bias tool for animal studies. Study characteristics and outcome measures were highly heterogeneous, and there was an unclear or high risk of bias in all studies. We therefore present a narrative synthesis of the evidence identified. None of the studies reported a sample size calculation. Out of over 60 different outcomes, we found evidence of discomfort due to ear clipping in the form of increased respiratory volume, vocalization and blood pressure. For toe clipping, increased vocalization and decreased motor activity in pups were found, as well as long-term effects in the form of reduced grip strength and swimming ability in adults. In conclusion, there

  10. Catheter Entrapment During Posterior Mitral Leaflet Pushing Maneuver for MitraClip Implantation.

    Science.gov (United States)

    Castrodeza, Javier; Amat-Santos, Ignacio J; Tobar, Javier; Varela-Falcón, Luis H

    2016-06-01

    MitraClip (Abbott Vascular) therapy has been reported to be an effective procedure for mitral regurgitation, especially in high-risk patients. Recently, the novel pushing maneuver technique has been described for approaching restricted and short posterior leaflets with a pigtail catheter in order to facilitate grasping of the clip. However, complications or unexpected situations may occur. We report the case of an 84-year-old patient who underwent MitraClip implantation wherein the pushing maneuver was complicated by the clip accidentally gripping the pigtail catheter along with the two leaflets.

  11. Definition of postlumpectomy tumor bed for radiotherapy boost field planning: CT versus surgical clips

    International Nuclear Information System (INIS)

    Goldberg, Hadassah; Prosnitz, Robert G.; Olson, John A.; Marks, Lawrence B.

    2005-01-01

    Purpose: To compare the location and extent of the tumor bed as defined by surgical clips and computed tomography (CT) scans, after lumpectomy, for electron boost planning as part of breast radiotherapy. Methods and Materials: Planning CT images of 31 operated breasts in 30 patients who underwent lumpectomy were reviewed. One or more clips were placed in the lumpectomy cavity. Serial CT images were used to measure the depth and transverse and longitudinal dimensions. The area and geometric center of the tumor bed were defined by the clips and CT. Results: The CT and clip measurements were identical for the maximal tumor depth in 27 of 30 patients. The CT bed extended beyond the clips by 0-7 mm medially in the transverse/longitudinal extent (multiclip patients). The median distance between the geometric centers in the coronal plane for the tumor bed center was larger for patients with single clips than for those with multiple clips (p 2 . The CT bed was more readily visible in patients with a shorter interval between surgery and radiotherapy. Conclusion: The maximal depth of the tumor bed was similar using the two methods. The extent and centers of the clip-and CT-determined beds differed significantly. This may indicate an underestimation of the tumor bed as defined by clips only and justifies integration of CT information in boost field planning

  12. Electric circuits essentials

    CERN Document Server

    REA, Editors of

    2012-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Electric Circuits I includes units, notation, resistive circuits, experimental laws, transient circuits, network theorems, techniques of circuit analysis, sinusoidal analysis, polyph

  13. Piezoelectric drive circuit

    Science.gov (United States)

    Treu, C.A. Jr.

    1999-08-31

    A piezoelectric motor drive circuit is provided which utilizes the piezoelectric elements as oscillators and a Meacham half-bridge approach to develop feedback from the motor ground circuit to produce a signal to drive amplifiers to power the motor. The circuit automatically compensates for shifts in harmonic frequency of the piezoelectric elements due to pressure and temperature changes. 7 figs.

  14. Load testing circuit

    DEFF Research Database (Denmark)

    2009-01-01

    A load testing circuit a circuit tests the load impedance of a load connected to an amplifier. The load impedance includes a first terminal and a second terminal, the load testing circuit comprising a signal generator providing a test signal of a defined bandwidth to the first terminal of the load...

  15. Short-circuit logic

    NARCIS (Netherlands)

    Bergstra, J.A.; Ponse, A.

    2010-01-01

    Short-circuit evaluation denotes the semantics of propositional connectives in which the second argument is only evaluated if the first argument does not suffice to determine the value of the expression. In programming, short-circuit evaluation is widely used. A short-circuit logic is a variant of

  16. Signal sampling circuit

    NARCIS (Netherlands)

    Louwsma, S.M.; Vertregt, Maarten

    2011-01-01

    A sampling circuit for sampling a signal is disclosed. The sampling circuit comprises a plurality of sampling channels adapted to sample the signal in time-multiplexed fashion, each sampling channel comprising a respective track-and-hold circuit connected to a respective analogue to digital

  17. Signal sampling circuit

    NARCIS (Netherlands)

    Louwsma, S.M.; Vertregt, Maarten

    2010-01-01

    A sampling circuit for sampling a signal is disclosed. The sampling circuit comprises a plurality of sampling channels adapted to sample the signal in time-multiplexed fashion, each sampling channel comprising a respective track-and-hold circuit connected to a respective analogue to digital

  18. [MitraClip® for treatment of tricuspid valve insufficiency].

    Science.gov (United States)

    Pfister, R; Baldus, S

    2017-11-01

    Tricuspid valve regurgitation is frequently found as a result of right ventricular remodeling due to advanced left heart diseases. Drug treatment is limited to diuretics and the cardiac or pulmonary comorbidities. Due to the high risk only a small percentage of patients are amenable to surgical treatment of tricuspid regurgitation in those who undergo left-sided surgery for other reasons. Catheter-based procedures are an attractive treatment alternative, particularly since the strong prognostic impact of tricuspid regurgitation suggests an unmet need of treatment, independent of the underlying heart disease. A vast amount of clinical experience exists for the MitraClip system for treatment of mitral regurgitation. A first case series shows that the application for treatment of tricuspid regurgitation is technically feasible, seems to be safe and the degree of valve regurgitation can be reduced. In this review the background of tricuspid regurgitation treatment is summarized and first experiences and perspectives with the MitraClip system are assessed.

  19. BioClips of symmetric and asymmetric cell division.

    Science.gov (United States)

    Lu, Fong-Mei; Eliceiri, Kevin W; White, John G

    2007-05-01

    Animations have long been used as tools to illustrate complex processes in such diverse fields as mechanical engineering, astronomy, bacteriology and physics. Animations in biology hold particular educational promise for depicting complex dynamic processes, such as photosynthesis, motility, viral replication and cellular respiration, which cannot be easily explained using static two-dimensional images. However, these animations have often been restrictive in scope, having been created for a specific classroom or research audience. In recent years, a new type of animation has emerged called the BioClip (http://www.bioclips.com) that strives to present science in an interactive multimedia format, which is, at once, informative and entertaining, by combining animations, text descriptions and music in one portable cross-platform document. In the present article, we illustrate the educational value of this new electronic resource by reviewing in depth two BioClips our group has created which describe the processes of symmetric and asymmetric cell division (http://www.wormclassroom.org/cb/bioclip).

  20. Feedback in analog circuits

    CERN Document Server

    Ochoa, Agustin

    2016-01-01

    This book describes a consistent and direct methodology to the analysis and design of analog circuits with particular application to circuits containing feedback. The analysis and design of circuits containing feedback is generally presented by either following a series of examples where each circuit is simplified through the use of insight or experience (someone else’s), or a complete nodal-matrix analysis generating lots of algebra. Neither of these approaches leads to gaining insight into the design process easily. The author develops a systematic approach to circuit analysis, the Driving Point Impedance and Signal Flow Graphs (DPI/SFG) method that does not require a-priori insight to the circuit being considered and results in factored analysis supporting the design function. This approach enables designers to account fully for loading and the bi-directional nature of elements both in the feedback path and in the amplifier itself, properties many times assumed negligible and ignored. Feedback circuits a...

  1. Effects of Japanese beetle (Coleoptera: Scarabaeidae) and silk clipping in field corn.

    Science.gov (United States)

    Steckel, Sandy; Stewart, S D; Tindall, K V

    2013-10-01

    Japanese beetle (Popillia japonica Newman) is an emerging silk-feeding insect found in fields in the lower Corn Belt and Midsouthern United States. Studies were conducted in 2010 and 2011 to evaluate how silk clipping in corn affects pollination and yield parameters. Manually clipping silks once daily had modest effects on yield parameters. Sustained clipping by either manually clipping silks three times per day or by caging Japanese beetles onto ears affected total kernel weight if it occurred during early silking (R1 growth stage). Manually clipping silks three times per day for the first 5 d of silking affected the number of kernels per ear, total kernel weight, and the weight of individual kernels. Caged beetles fed on silks and, depending on the number of beetles caged per ear, reduced the number of kernels per ear. Caging eight beetles per ear significantly reduced total kernel weight compared with noninfested ears. Drought stress before anthesis appeared to magnify the impact of silk clipping by Japanese beetles. There was evidence of some compensation for reduced pollination by increasing the size of pollinated kernels within the ear. Our results showed that it requires sustained silk clipping during the first week of silking to have substantial impacts on pollination and yield parameters, at least under good growing conditions. Some states recommend treating for Japanese beetle when three Japanese beetles per ear are found, silks are clipped to < 13 mm, and pollination is < 50% complete, and that recommendation appears to be adequate.

  2. The "Isms" of Art. Introduction to the 2001-2002 Clip and Save Art Prints.

    Science.gov (United States)

    Hubbard, Guy

    2001-01-01

    Provides an introduction to the 2001-2002 Clip and Save Art Prints that will focus on ten art movements from the past 150 years. Includes information on three art movements, or "isms": Classicism, Romanticism, and Realism. Discusses the Clip and Save Art Print format and provides information on three artists. (CMK)

  3. Suture retraction technique to prevent parent vessel obstruction following aneurysm tandem clipping.

    Science.gov (United States)

    Rayan, Tarek; Amin-Hanjani, Sepideh

    2015-08-01

    With large or giant aneurysms, the use of multiple tandem clips can be essential for complete obliteration of the aneurysm. One potential disadvantage, however, is the considerable cumulative weight of these clips, which may lead to kinking of the underlying parent vessels and obstruction of flow. The authors describe a simple technique to address this problem, guided by intraoperative blood flow measurements, in a patient with a ruptured near-giant 2.2 × 1.7-cm middle cerebral artery bifurcation aneurysm that was treated with the tandem clipping technique. A total of 11 clips were applied in a vertical stacked fashion. The cumulative weight of the clips caused kinking of the temporal M2 branch of the bifurcation with reduction of flow. A 4-0 Nurolon suture tie was applied to the hub of one of the clips and was tethered to the dura of the sphenoid ridge by a small mini-clip and reinforced by application of tissue sealant. The patient underwent intraoperative indocyanine green videoangiography as well as catheter angiography, which demonstrated complete aneurysmal obliteration and preservation of vessel branches. Postoperative angiography confirmed patency of the bifurcation vessels with mild vasospasm. The patient had a full recovery with no postoperative complications and was neurologically intact at her 6-month follow-up. The suture retraction technique allows a simple solution to parent vessel obstruction following aneurysm tandem clipping, in conjunction with the essential guidance provided by intraoperative flow measurements.

  4. Establishment of an easy Ic measurement method of HTS superconducting tapes using clipped voltage taps

    International Nuclear Information System (INIS)

    Shin, Hyung Seop; Nisay, Arman; Dedicatoria, Marlon; Sim, Ki Deok

    2014-01-01

    The critical current, I c of HTS superconducting tapes can be measured by transport or contactless method. Practically, the transport method using the four-probe method is the most common. In this study, a simple test procedure by clipping the voltage lead taps have been introduced instead of soldering which reduces time and effort and thereby achieving a much faster measurement of I c . When using a pair of iron clips, I c value decreased as compared with the measured one by standard method using soldered voltage taps and varies with the width of the clipped specimen part. However, when using a pure Cu clip, both by clipping and by soldering voltage taps give a comparable result and I c measured are equal and close to the samples specification. As a result, material to be used as voltage clip should be considered and should not influence the potential voltage between the leads during I c measurement. Furthermore, the simulation result of magnetic flux during I c measurement test showed that the decrease of I c observed in the experiment is due to the magnetic flux density, By produced at the clipped part of the sample by the operating current with iron clips attached to the sample.

  5. Capturing Students' Attention: Movie Clips Set the Stage for Learning in Abnormal Psychology.

    Science.gov (United States)

    Badura, Amy S.

    2002-01-01

    Presents results of a study that evaluated using popular movie clips, shown in the first class meeting of an abnormal psychology course, in relation to student enthusiasm. Compares two classes of female juniors, one using clips and one class not using them. States that the films portrayed psychological disorders. (CMK)

  6. Using Film Clips to Teach Teen Pregnancy Prevention: "The Gloucester 18" at a Teen Summit

    Science.gov (United States)

    Herrman, Judith W.; Moore, Christopher C.; Anthony, Becky

    2012-01-01

    Teaching pregnancy prevention to large groups offers many challenges. This article describes the use of film clips, with guided discussion, to teach pregnancy prevention. In order to analyze the costs associated with teen pregnancy, a film clip discussion session based with the film "The Gloucester 18" was the keynote of a youth summit. The lesson…

  7. A systematic review of discomfort due to toe or ear clipping in laboratory rodents

    NARCIS (Netherlands)

    Wever, K.E.; Geessink, F.J.; Brouwer, M.A.E.; Tillema, A.; Ritskes-Hoitinga, M.

    2017-01-01

    Toe clipping and ear clipping (also ear notching or ear punching) are frequently used methods for individual identification of laboratory rodents. These procedures potentially cause severe discomfort, which can reduce animal welfare and distort experimental results. However, no systematic summary of

  8. Real-world experience of MitraClip for treatment of severe mitral regurgitation

    DEFF Research Database (Denmark)

    Chan, Pak Hei; She, Hoi Lam; Alegria-Barrero, Eduardo

    2012-01-01

     Percutaneous edge-to-edge mitral valve repair with the MitraClip(®) was shown to be a safe and feasible alternative compared to conventional surgical mitral valve repair. Herein is reported our experience on MitraClip(®) for high-risk surgical candidates with severe mitral regurgitation (MR)....

  9. [Clip Sheets from BOCES. Opportunities. Health. Careers. = Oportunidades. Salud. Una Camera En...

    Science.gov (United States)

    State Univ. of New York, Geneseo. Coll. at Geneseo. Migrant Center.

    This collection of 83 clip sheets, or classroom handouts, was created to help U.S. migrants learn more about health, careers, and general "opportunities" including education programs. They are written in both English and Spanish and are presented in an easily understandable format. Health clip-sheet topics include the following: Abuse; AIDS;…

  10. Bayesian Recovery of Clipped OFDM Signals: A Receiver-based Approach

    KAUST Repository

    Al-Rabah, Abdullatif R.

    2013-01-01

    recovery algorithm to reconstruct the clipping signal at the receiver side by measuring part of subcarriers, iii) perform well in the absence of statistical information about the signal (e.g. clipping level) and the noise (e.g. noise variance

  11. Using Short Movie and Television Clips in the Economics Principles Class

    Science.gov (United States)

    Sexton, Robert L.

    2006-01-01

    The author describes a teaching method that uses powerful contemporary media, movie and television clips, to demonstrate the enormous breadth and depth of economic concepts. Many different movie and television clips can be used to show the power of economic analysis. The author describes the scenes and the economic concepts within those scenes for…

  12. Molecular Recognition Involving Anthraquinone Derivatives and Molecular Clips

    Science.gov (United States)

    Alaparthi, Madhubabu

    In the past, we have demonstrated that 1,8-anthraquinone-18-crown-5 (1) and its heterocyclic derivatives act as luminescent hosts for a variety of cations of environmental and clinical concern. We report here a series of heteroatom-substituted macrocycles containing an anthraquinone moiety as a fluorescent signaling unit and a cyclic polyheteroether chain as the receptor. Sulfur, selenium, and tellurium derivatives of 1,8-anthraquinone-18-crown-5 (1) were synthesized by reacting sodium sulfide (Na2S), sodium selenide (Na2Se) and sodium telluride (Na2Te) with 1,8-bis(2-bromoethylethyleneoxy)anthracene - 9,10-dione in a 1:1 ratio (2,3, and 6). These sensors bind metal ions in a 1:1 ratio (7 and 8), and the optical properties of the new complexes were examined and the sulfur and selenium analogues show that selectivity for Pb(II) is markedly improved as compared to the oxygen analogue 1 which was competitive for Ca(II) ion. Selective reduction of 1 yields secondary alcohols where either one or both of the anthraquinone carbonyl groups has been reduced ( 15 and 9). A new mechanism for the fluorescence detection of metal cations in solution is introduced involving a unique keto-enol tautomerization. Reduction of 1 yields the doubly reduced secondary alcohol, 9. 9 acts as a chemodosimeter for Al(III) ion producing a strong blue emission due to the formation of the anthracene fluorophore, 10, via dehydration of the internal secondary alcohol in DMSO/aqueous solution. The enol form is not the most thermodynamically stable form under these conditions however, and slowly converts to the keto form 11.. Currently we are focusing on cucurbituril derivatives, also described as molecular clips due to their folded geometry used as molecular recognition hosts. We first investigated the synthesis and characterization of aromatic methoxy/catechol terminated cucurbituril units that act as hosts for small solvent molecules, such as CH2Cl2, CH3CN, DMF, and MeOH, through dual pi...H-C T

  13. Biochemical Analysis Reveals the Multifactorial Mechanism of Histone H3 Clipping by Chicken Liver Histone H3 Protease

    KAUST Repository

    Chauhan, Sakshi; Mandal, Papita; Tomar, Raghuvir S.

    2016-01-01

    Proteolytic clipping of histone H3 has been identified in many organisms. Despite several studies, the mechanism of clipping, the substrate specificity, and the significance of this poorly understood epigenetic mechanism are not clear. We have

  14. Assessing arsenic and selenium in a single nail clipping using portable X-ray fluorescence

    International Nuclear Information System (INIS)

    Fleming, David E.B.; Nader, Michel N.; Foran, Kelly A.; Groskopf, Craig; Reno, Michael C.; Ware, Chris S.; Tehrani, Mina; Guimarães, Diana; Parsons, Patrick J.

    2017-01-01

    The feasibility of measuring arsenic and selenium contents in a single nail clipping was investigated using a small-focus portable X-ray fluorescence (XRF) instrument with monochromatic excitation beams. Nail clipping phantoms supplemented with arsenic and selenium to produce materials with 0, 5, 10, 15, and 20 µg/g were used for calibration purposes. In total, 10 different clippings were analyzed at two different measurement positions. Energy spectra were fit with detection peaks for arsenic K_α, selenium K_α, arsenic K_β, selenium K_β, and bromine K_α characteristic X-rays. Data analysis was performed under two distinct conditions of fitting constraint. Calibration lines were established from the amplitude of each of the arsenic and selenium peaks as a function of the elemental contents in the clippings. The slopes of the four calibration lines were consistent between the two conditions of analysis. The calculated minimum detection limit (MDL) of the method, when considering the K_α peak only, ranged from 0.210±0.002 µg/g selenium under one condition of analysis to 0.777±0.009 µg/g selenium under another. Compared with previous portable XRF nail clipping studies, MDLs were substantially improved for both arsenic and selenium. The new measurement technique had the additional benefits of being short in duration (~3 min) and requiring only a single nail clipping. The mass of the individual clipping used did not appear to play a major role in signal strength, but positioning of the clipping is important. - Highlights: • Portable X-ray fluorescence was used to assess As and Se in nail clipping phantoms. • Calibration lines were consistent between two different conditions of data analysis. • This new XRF approach was sensitive and required only a single nail clipping.

  15. Multivariate Cryptography Based on Clipped Hopfield Neural Network.

    Science.gov (United States)

    Wang, Jia; Cheng, Lee-Ming; Su, Tong

    2018-02-01

    Designing secure and efficient multivariate public key cryptosystems [multivariate cryptography (MVC)] to strengthen the security of RSA and ECC in conventional and quantum computational environment continues to be a challenging research in recent years. In this paper, we will describe multivariate public key cryptosystems based on extended Clipped Hopfield Neural Network (CHNN) and implement it using the MVC (CHNN-MVC) framework operated in space. The Diffie-Hellman key exchange algorithm is extended into the matrix field, which illustrates the feasibility of its new applications in both classic and postquantum cryptography. The efficiency and security of our proposed new public key cryptosystem CHNN-MVC are simulated and found to be NP-hard. The proposed algorithm will strengthen multivariate public key cryptosystems and allows hardware realization practicality.

  16. Electric circuits and signals

    CERN Document Server

    Sabah, Nassir H

    2007-01-01

    Circuit Variables and Elements Overview Learning Objectives Electric Current Voltage Electric Power and Energy Assigned Positive Directions Active and Passive Circuit Elements Voltage and Current Sources The Resistor The Capacitor The Inductor Concluding Remarks Summary of Main Concepts and Results Learning Outcomes Supplementary Topics on CD Problems and Exercises Basic Circuit Connections and Laws Overview Learning Objectives Circuit Terminology Kirchhoff's Laws Voltage Division and Series Connection of Resistors Current Division and Parallel Connection of Resistors D-Y Transformation Source Equivalence and Transformation Reduced-Voltage Supply Summary of Main Concepts and Results Learning Outcomes Supplementary Topics and Examples on CD Problems and Exercises Basic Analysis of Resistive Circuits Overview Learning Objectives Number of Independent Circuit Equations Node-Voltage Analysis Special Considerations in Node-Voltage Analysis Mesh-Current Analysis Special Conside...

  17. [Shunt and short circuit].

    Science.gov (United States)

    Rangel-Abundis, Alberto

    2006-01-01

    Shunt and short circuit are antonyms. In French, the term shunt has been adopted to denote the alternative pathway of blood flow. However, in French, as well as in Spanish, the word short circuit (court-circuit and cortocircuito) is synonymous with shunt, giving rise to a linguistic and scientific inconsistency. Scientific because shunt and short circuit made reference to a phenomenon that occurs in the field of the physics. Because shunt and short circuit are antonyms, it is necessary to clarify that shunt is an alternative pathway of flow from a net of high resistance to a net of low resistance, maintaining the stream. Short circuit is the interruption of the flow, because a high resistance impeaches the flood. This concept is applied to electrical and cardiovascular physiology, as well as to the metabolic pathways.

  18. Analog circuits cookbook

    CERN Document Server

    Hickman, Ian

    2013-01-01

    Analog Circuits Cookbook presents articles about advanced circuit techniques, components and concepts, useful IC for analog signal processing in the audio range, direct digital synthesis, and ingenious video op-amp. The book also includes articles about amplitude measurements on RF signals, linear optical imager, power supplies and devices, and RF circuits and techniques. Professionals and students of electrical engineering will find the book informative and useful.

  19. Analog circuit design

    CERN Document Server

    Dobkin, Bob

    2012-01-01

    Analog circuit and system design today is more essential than ever before. With the growth of digital systems, wireless communications, complex industrial and automotive systems, designers are being challenged to develop sophisticated analog solutions. This comprehensive source book of circuit design solutions aids engineers with elegant and practical design techniques that focus on common analog challenges. The book's in-depth application examples provide insight into circuit design and application solutions that you can apply in today's demanding designs. <

  20. Regenerative feedback resonant circuit

    Science.gov (United States)

    Jones, A. Mark; Kelly, James F.; McCloy, John S.; McMakin, Douglas L.

    2014-09-02

    A regenerative feedback resonant circuit for measuring a transient response in a loop is disclosed. The circuit includes an amplifier for generating a signal in the loop. The circuit further includes a resonator having a resonant cavity and a material located within the cavity. The signal sent into the resonator produces a resonant frequency. A variation of the resonant frequency due to perturbations in electromagnetic properties of the material is measured.

  1. Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study

    Directory of Open Access Journals (Sweden)

    Schenk Martin

    2016-09-01

    Full Text Available The use of surgical ligation clips is considered as the gold standard for the closure of vessels, particularly in laparoscopic surgery. The safety of clips is mainly achieved by the deep indentation of the metal bar with a high retention force. A novel double-shanked (DS titanium clip was compared to two single-shanked clips with respect to axial and radial pull-off forces.

  2. CMOS circuits manual

    CERN Document Server

    Marston, R M

    1995-01-01

    CMOS Circuits Manual is a user's guide for CMOS. The book emphasizes the practical aspects of CMOS and provides circuits, tables, and graphs to further relate the fundamentals with the applications. The text first discusses the basic principles and characteristics of the CMOS devices. The succeeding chapters detail the types of CMOS IC, including simple inverter, gate and logic ICs and circuits, and complex counters and decoders. The last chapter presents a miscellaneous collection of two dozen useful CMOS circuits. The book will be useful to researchers and professionals who employ CMOS circu

  3. Timergenerator circuits manual

    CERN Document Server

    Marston, R M

    2013-01-01

    Timer/Generator Circuits Manual is an 11-chapter text that deals mainly with waveform generator techniques and circuits. Each chapter starts with an explanation of the basic principles of its subject followed by a wide range of practical circuit designs. This work presents a total of over 300 practical circuits, diagrams, and tables.Chapter 1 outlines the basic principles and the different types of generator. Chapters 2 to 9 deal with a specific type of waveform generator, including sine, square, triangular, sawtooth, and special waveform generators pulse. These chapters also include pulse gen

  4. Electronic devices and circuits

    CERN Document Server

    Pridham, Gordon John

    1968-01-01

    Electronic Devices and Circuits, Volume 1 deals with the design and applications of electronic devices and circuits such as passive components, diodes, triodes and transistors, rectification and power supplies, amplifying circuits, electronic instruments, and oscillators. These topics are supported with introductory network theory and physics. This volume is comprised of nine chapters and begins by explaining the operation of resistive, inductive, and capacitive elements in direct and alternating current circuits. The theory for some of the expressions quoted in later chapters is presented. Th

  5. Maximum Acceleration Recording Circuit

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Coarsely digitized maximum levels recorded in blown fuses. Circuit feeds power to accelerometer and makes nonvolatile record of maximum level to which output of accelerometer rises during measurement interval. In comparison with inertia-type single-preset-trip-point mechanical maximum-acceleration-recording devices, circuit weighs less, occupies less space, and records accelerations within narrower bands of uncertainty. In comparison with prior electronic data-acquisition systems designed for same purpose, circuit simpler, less bulky, consumes less power, costs and analysis of data recorded in magnetic or electronic memory devices. Circuit used, for example, to record accelerations to which commodities subjected during transportation on trucks.

  6. MOS integrated circuit design

    CERN Document Server

    Wolfendale, E

    2013-01-01

    MOS Integral Circuit Design aims to help in the design of integrated circuits, especially large-scale ones, using MOS Technology through teaching of techniques, practical applications, and examples. The book covers topics such as design equation and process parameters; MOS static and dynamic circuits; logic design techniques, system partitioning, and layout techniques. Also featured are computer aids such as logic simulation and mask layout, as well as examples on simple MOS design. The text is recommended for electrical engineers who would like to know how to use MOS for integral circuit desi

  7. Circuits and filters handbook

    CERN Document Server

    Chen, Wai-Kai

    2003-01-01

    A bestseller in its first edition, The Circuits and Filters Handbook has been thoroughly updated to provide the most current, most comprehensive information available in both the classical and emerging fields of circuits and filters, both analog and digital. This edition contains 29 new chapters, with significant additions in the areas of computer-aided design, circuit simulation, VLSI circuits, design automation, and active and digital filters. It will undoubtedly take its place as the engineer's first choice in looking for solutions to problems encountered in the design, analysis, and behavi

  8. Security electronics circuits manual

    CERN Document Server

    MARSTON, R M

    1998-01-01

    Security Electronics Circuits Manual is an invaluable guide for engineers and technicians in the security industry. It will also prove to be a useful guide for students and experimenters, as well as providing experienced amateurs and DIY enthusiasts with numerous ideas to protect their homes, businesses and properties.As with all Ray Marston's Circuits Manuals, the style is easy-to-read and non-mathematical, with the emphasis firmly on practical applications, circuits and design ideas. The ICs and other devices used in the practical circuits are modestly priced and readily available ty

  9. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION WITH CLIPSITS)

    Science.gov (United States)

    Riley, , .

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh

  10. 76 FR 31360 - Paper Clips From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping...

    Science.gov (United States)

    2011-05-31

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-663 Third Review] Paper Clips From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping Duty Order on Paper Clips From China... paper clips from China would be likely to lead to continuation or recurrence of material injury within a...

  11. Structural changes in the human vas deferens after tantalum clip occlusion and conventional vasectomy.

    Science.gov (United States)

    Kothari, L K; Gupta, A S

    1978-02-01

    In 15 human subjects, the vasa deferentia were occluded by applying two tantalum clips on one side and by conventional vasectomy with silk ligatures on the other. After 2 weeks, the occluded segments were recovered for histopathologic examination of serial sections. Obstructing the seminal tract did not, as such, produce any significant change in the vas: the distal and proximal segments appeared to be essentially similar and normal. At the actual site of occlusion, however, tantalum clips produced marked flattening of the tube, complete loss of lining epithelium, distortion of the muscular lamellae, and areas of hemorrhage. The lumen was converted into a narrow slit. Under the ligatures, the damage was largely confined to denudation of the mucosal epithelium. The mucosa of the intersegment left unexcised between two clips showed hyalinization, invasion by macrophages, and degeneration of the epithelium. The changes under the clips suggest that, although clip occlusion may offer several advantages, sterility cannot be reversed merely by removing the clips. The mechanisms of these changes, different in the case of clips and ligatures, are discussed and some possible long-term consequences are considered.

  12. Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips.

    Science.gov (United States)

    Schulz-Wendtland, R; Dankerl, P; Dilbat, G; Bani, M; Fasching, P A; Heusinger, K; Lux, M P; Loehberg, C R; Jud, S M; Rauh, C; Bayer, C M; Beckmann, M W; Wachter, D L; Uder, M; Meier-Meitinger, M; Brehm, B

    2015-01-01

    Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography.

  13. Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids

    Directory of Open Access Journals (Sweden)

    Aashish Sasidharan

    2015-01-01

    Full Text Available Background: Keloids of the ear are common problems. Various treatment modalities are available for the treatment of ear keloids. Surgical excision with intralesional steroid injection along with compression therapy has the least recurrence rate. Various types of devices are available for pressure therapy. Pressure applied by these devices is uncontrolled and is associated with the risk of pressure necrosis. We describe here a simple and easy to use device to measure pressure applied by these clips for better outcome. Objectives: To devise a simple method to measure the pressure applied by various pressure clips used in ear keloid pressure therapy. Materials and Methods: By using a force sensitive resistor (FSR, the pressure applied gets converted into voltage using electrical wires, resistors, capacitors, converter, amplifier, diode, nine-volt (9V cadmium battery and the voltage is measured using a multimeter. The measured voltage is then converted into pressure using pressure voltage graph that depicts the actual pressure applied by the pressure clip. Results: The pressure applied by different clips was variable. The spring clips were adjustable by slight variation in the design whereas the pressure applied by binder clips and magnet discs was not adjustable. Conclusion: The uncontrolled/suboptimal pressure applied by certain pressure clips can be monitored to provide optimal pressure therapy in ear keloid for better outcome.

  14. Circuits on Cylinders

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Arnsfelt; Miltersen, Peter Bro; Vinay, V

    2006-01-01

    We consider the computational power of constant width polynomial size cylindrical circuits and nondeterministic branching programs. We show that every function computed by a Pi2 o MOD o AC0 circuit can also be computed by a constant width polynomial size cylindrical nondeterministic branching pro...

  15. What kind of erotic film clips should we use in female sex research? An exploratory study.

    Science.gov (United States)

    Woodard, Terri L; Collins, Karen; Perez, Mindy; Balon, Richard; Tancer, Manuel E; Kruger, Michael; Moffat, Scott; Diamond, Michael P

    2008-01-01

    Erotic film clips are used in sex research, including studies of female sexual dysfunction and arousal. However, little is known about which clips optimize female sexual response. Furthermore, their use is not well standardized. To identify the types of film clips that are most mentally appealing and physically arousing to women for use in future sexual function and dysfunction studies; to explore the relationship between mental appeal and reported physical arousal; to characterize the content of the films that were found to be the most and least appealing and arousing. Twenty-one women viewed 90 segments of erotic film clips. They rated how (i) mentally appealing and (ii) how physically aroused they were by each clip. The data were analyzed by descriptive statistics. The means of the mental and self-reported physical responses were calculated to determine the most and least appealing/arousing film clips. Pearson correlations were calculated to assess the relationship between mental appeal and reported physical arousal. Self-reported mental and physical arousal. Of 90 film clips, 18 were identified as the most mentally appealing and physically arousing while nine were identified as the least mentally appealing and physically arousing. The level of mental appeal positively correlated with the level of perceived physical arousal in both categories (r = 0.61, P Erotic film clips reliably produced a state of self-reported arousal in women. The most appealing and arousing films tended to depict heterosexual vaginal intercourse. Film clips with these attributes should be used in future research of sexual function and response of women.

  16. Virtual Cerebral Aneurysm Clipping with Real-Time Haptic Force Feedback in Neurosurgical Education.

    Science.gov (United States)

    Gmeiner, Matthias; Dirnberger, Johannes; Fenz, Wolfgang; Gollwitzer, Maria; Wurm, Gabriele; Trenkler, Johannes; Gruber, Andreas

    2018-04-01

    Realistic, safe, and efficient modalities for simulation-based training are highly warranted to enhance the quality of surgical education, and they should be incorporated in resident training. The aim of this study was to develop a patient-specific virtual cerebral aneurysm-clipping simulator with haptic force feedback and real-time deformation of the aneurysm and vessels. A prototype simulator was developed from 2012 to 2016. Evaluation of virtual clipping by blood flow simulation was integrated in this software, and the prototype was evaluated by 18 neurosurgeons. In 4 patients with different medial cerebral artery aneurysms, virtual clipping was performed after real-life surgery, and surgical results were compared regarding clip application, surgical trajectory, and blood flow. After head positioning and craniotomy, bimanual virtual aneurysm clipping with an original forceps was performed. Blood flow simulation demonstrated residual aneurysm filling or branch stenosis. The simulator improved anatomic understanding for 89% of neurosurgeons. Simulation of head positioning and craniotomy was considered realistic by 89% and 94% of users, respectively. Most participants agreed that this simulator should be integrated into neurosurgical education (94%). Our illustrative cases demonstrated that virtual aneurysm surgery was possible using the same trajectory as in real-life cases. Both virtual clipping and blood flow simulation were realistic in broad-based but not calcified aneurysms. Virtual clipping of a calcified aneurysm could be performed using the same surgical trajectory, but not the same clip type. We have successfully developed a virtual aneurysm-clipping simulator. Next, we will prospectively evaluate this device for surgical procedure planning and education. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Portable x-ray fluorescence for the analysis of chromium in nail and nail clippings

    International Nuclear Information System (INIS)

    Fleming, David E.B.; Ware, Chris S.

    2017-01-01

    Assessment of chromium content in human nail or nail clippings could serve as an effective biomarker of chromium status. The feasibility of a new portable x-ray fluorescence (XRF) approach to chromium measurement was investigated through analysis of nail and nail clipping phantoms. Five measurements of 180 s (real time) duration were first performed on six whole nail phantoms having chromium concentrations of 0, 2, 5, 10, 15, and 20 µg/g. Using nail clippers, these phantoms were then converted to nail clippings, and assembled into different mass groups of 20, 40, 60, 80, and 100 mg for additional measurements. The amplitude of the chromium Kα characteristic x-ray energy peak was examined as a function of phantom concentration for all measurement conditions to create a series of calibration lines. The minimum detection limit (MDL) for chromium was also calculated for each case. The chromium MDL determined from the whole nail intact phantoms was 0.88±0.03 µg/g. For the clipping phantoms, the MDL ranged from 1.2 to 3.3 µg/g, depending on the mass group analyzed. For the 40 mg clipping group, the MDL was 1.2±0.1 µg/g, and higher mass collections did not improve upon this result. This MDL is comparable to chromium concentration levels seen in various studies involving human nail clippings. Further improvements to the portable XRF technique would be required to detect chromium levels expected from the lower end of a typical population. - Highlights: • Portable x-ray fluorescence (XRF) was explored as a technique to assess levels of chromium in human nails or nail clippings. • Results were found to depend on the mass of clipping sample provided. • Minimum detection limits for chromium were similar to concentration levels found in previous studies of human nail clippings.

  18. CMOS analog circuit design

    CERN Document Server

    Allen, Phillip E

    1987-01-01

    This text presents the principles and techniques for designing analog circuits to be implemented in a CMOS technology. The level is appropriate for seniors and graduate students familiar with basic electronics, including biasing, modeling, circuit analysis, and some familiarity with frequency response. Students learn the methodology of analog integrated circuit design through a hierarchically-oriented approach to the subject that provides thorough background and practical guidance for designing CMOS analog circuits, including modeling, simulation, and testing. The authors' vast industrial experience and knowledge is reflected in the circuits, techniques, and principles presented. They even identify the many common pitfalls that lie in the path of the beginning designer--expert advice from veteran designers. The text mixes the academic and practical viewpoints in a treatment that is neither superficial nor overly detailed, providing the perfect balance.

  19. Successful Removal of Football Helmet Face-Mask Clips After 1 Season of Use

    Science.gov (United States)

    Scibek, Jason S.; Gatti, Joseph M.; McKenzie, Jennifer I.

    2012-01-01

    Context Whereas many researchers have assessed the ability to remove loop straps in traditional face-mask attachment systems after at least 1 season of use, research in which the effectiveness of the Riddell Quick Release (QR) Face Guard Attachment System clip after 1 season has been assessed is limited. Objective To examine the success rate of removing the QR clips after 1 season of use at the Football Championship Subdivision level. We hypothesized that 1 season of use would negatively affect the removal rate of the QR clip but repeated clip-removal trials would improve the removal rate. Design Retrospective, quasi-experimental design. Setting Controlled laboratory study. Patients or Other Participants Sixty-three football helmets from a National Collegiate Athletic Association Division I university located in western Pennsylvania used during the 2008 season were tested. Intervention(s) Three certified athletic trainers (2 men, 1 woman; age = 31.3 ± 3.06 years, time certified = 9.42 ± 2.65 years) attempted to remove the QR clips from each helmet with the tool provided by the manufacturer. Helmets then were reassembled to allow each athletic trainer to attempt clip removal. Main Outcome Measure(s) The dependent variables were total left clips removed (TCR-L), total right clips removed (TCR-R), and total clips removed (TCR). Success rate of clip removal (SRCR) also was assessed. Results Percentages for TCR-L, TCR-R, and TCR were 100% (189 of 189), 96.30% (182 of 189), and 98.15% (371 of 378), respectively. A paired-samples t test revealed a difference between TCR-R and TCR-L (t188 = −2.689, P = .008, μd = 0.037, 95% confidence interval [CI] = −0.064, −0.010). The percentage for SRCR was 96.30% (n = 182), whereas SRCR percentages for trials 1, 2, and 3 were 95.24% (n = 60), 98.41% (n = 62), and 95.24% (n = 60), respectively, and did not represent a difference (F2,186 = 0.588, P = .56, 95% CI = 0.94, 0.99). Conclusions Our results indicated favorable and

  20. Multichannel infinite clipping as a form of sampling of speech signals

    International Nuclear Information System (INIS)

    Guidarelli, G.

    1985-01-01

    A remarkable improvement of both intelligibility and naturalness of infinitely clipped speech can be achieved by means of a multichannel system in which the speech signal is splitted into several band-pass channels before the clipping and successively reconstructed by summing up the clipped outputs of each channel. A possible explanation of such an improvement is given, founded on the so-called zero-based representation of band limited signals where the zero-crossings sequence is considered as a set of samples of the signal

  1. Advantages in imaging results with titanium aneurysm clips (TiAl6V4)

    International Nuclear Information System (INIS)

    Piepgras, A.; Gueckel, F.; Weik, T.; Schmiedek, P.

    1995-01-01

    Aneurysm clips made of a titanium alloy (TiAl6V4) were used in clinical practice for the first time. The design of the clips is identical to the routinely used Yasargil series. In 30 patients, 38 symptomatic and asymptomatic aneurysms were fixed with 45 clips. Metallurgical advantages of the new alloy are better biocompatibility, less magnetic susceptibility, and lower X-ray density. The postoperative imaging results are superior to the conventionally used alloys with respect to artifact reduction in computed tomography, angiography, and magnetic resonance imaging. With a follow-up period of 7 months, a statement on biocompatibility cannot yet be given. (orig.) [de

  2. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (IBM PC VERSION)

    Science.gov (United States)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with

  3. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (UNIX VERSION)

    Science.gov (United States)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with

  4. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (MACINTOSH VERSION)

    Science.gov (United States)

    Riley, G.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with

  5. Approximate circuits for increased reliability

    Science.gov (United States)

    Hamlet, Jason R.; Mayo, Jackson R.

    2015-08-18

    Embodiments of the invention describe a Boolean circuit having a voter circuit and a plurality of approximate circuits each based, at least in part, on a reference circuit. The approximate circuits are each to generate one or more output signals based on values of received input signals. The voter circuit is to receive the one or more output signals generated by each of the approximate circuits, and is to output one or more signals corresponding to a majority value of the received signals. At least some of the approximate circuits are to generate an output value different than the reference circuit for one or more input signal values; however, for each possible input signal value, the majority values of the one or more output signals generated by the approximate circuits and received by the voter circuit correspond to output signal result values of the reference circuit.

  6. Supplemental knowledge acquisition through external product interface for CLIPS

    Science.gov (United States)

    Saito, Tim; Ebaud, Stephen; Loftin, Bowen R.

    1990-01-01

    Traditionally, the acquisition of knowledge for expert systems consisted of the interview process with the domain or subject matter expert (SME), observation of domain environment, and information gathering and research which constituted a direct form of knowledge acquisition (KA). The knowledge engineer would be responsible for accumulating pertinent information and/or knowledge from the SME(s) for input into the appropriate expert system development tool. The direct KA process may (or may not) have included forms of data or documentation to incorporate from the SME's surroundings. The differentiation between direct KA and supplemental KA (indirect) would be the difference in the use of data. In acquiring supplemental knowledge, the knowledge engineer would access other types of evidence (manuals, documents, data files, spreadsheets, etc.) that would support the reasoning or premises of the SME. When an expert makes a decision in a particular task, one tool that may have been used to justify a recommendation, would have been a spreadsheet total or column figure. Locating specific decision points from that data within the SME's framework would constitute supplemental KA. Data used for a specific purpose in one system or environment would be used as supplemental knowledge for another, specifically a CLIPS project.

  7. Neighbour effects on Erica multiflora (Ericaceae) reproductive performance after clipping

    Science.gov (United States)

    Vilà, Montserrat; Terradas, Jaume

    1998-04-01

    The effect of interspecific competition on resprouting and reproductive success and the relationship between above-ground vegetative biomass variability and reproductive biomass variability were analysed during resprouting after clipping. For this purpose, a field experiment was performed by removing neighbours around individuals of Erica multiflora in a Mediterranean shrub community. Removal of neighbours increased the number of sprouts and the above-ground vegetative biomass of target plants. However, it did not decrease plant size variability. Neighbours decreased the likelihood of fruiting and the biomass of fruits. In target plants that had set fruits a simple allometric relationship between above-ground vegetative biomass and the biomass of fruits explained 42% of the variation in fruit biomass. The probability to set fruits at a given plant size was smaller in plants with neighbours than without neighbours. Presence of neighbours also increased the variability of fruit biomass within the population, because 50% of target plants with neighbours did not set fruits. This failure to set fruits may be related to shading, the small size of plants with neighbours, as well as a delay in development.

  8. Fault Diagnosis of Motor Bearing by Analyzing a Video Clip

    Directory of Open Access Journals (Sweden)

    Siliang Lu

    2016-01-01

    Full Text Available Conventional bearing fault diagnosis methods require specialized instruments to acquire signals that can reflect the health condition of the bearing. For instance, an accelerometer is used to acquire vibration signals, whereas an encoder is used to measure motor shaft speed. This study proposes a new method for simplifying the instruments for motor bearing fault diagnosis. Specifically, a video clip recording of a running bearing system is captured using a cellphone that is equipped with a camera and a microphone. The recorded video is subsequently analyzed to obtain the instantaneous frequency of rotation (IFR. The instantaneous fault characteristic frequency (IFCF of the defective bearing is obtained by analyzing the sound signal that is recorded by the microphone. The fault characteristic order is calculated by dividing IFCF by IFR to identify the fault type of the bearing. The effectiveness and robustness of the proposed method are verified by a series of experiments. This study provides a simple, flexible, and effective solution for motor bearing fault diagnosis. Given that the signals are gathered using an affordable and accessible cellphone, the proposed method is proven suitable for diagnosing the health conditions of bearing systems that are located in remote areas where specialized instruments are unavailable or limited.

  9. Primitive experience of three dimensional multi-slice spiral CT angiography for the follow-up of intracranial aneurysm clipping

    International Nuclear Information System (INIS)

    Yang Yunjun; Chen Weijian; Hu Zhangyong; Wu Enfu; Wang Meihao; Zhuge Qichuan; Zhongming; Cheng Jingliang; Ren Cuiping; Zhang Yong

    2008-01-01

    Objective To evaluate multi-slice three-dimensional CT angiography (MS 3D-CTA) for the follow-up of intracranial aneurysm clipping. Methods: MS 3D-CTA of 16 patients with intracranial aneurysm clipping were retrospectively analyzed. The patients were scanned on a 16-slice spiral CT (GE Lightspeed pro). Volume rendering(VR), thin maximum intensity projection(thin MIP) and multi-planar reconstruction (MPR) were employed in image postprocessing in all cases. Results: There were 17 clips in the 16 patients with aneurysm clipping. Six clips were located at the posterior communicating artery, 5 at the anterior communicating artery, 4 at the middle cerebral artery, and the remaining 2 clips were located at the pericallosal artery, in 1 patient. There were no abnormalities found in the aneurysm clipping region in 7 cases by MS 3D- CTA. There were residual aneurysm in 2 cases, parent artery stenosis in 4 cases, and artery spasm in 3 eases. There was no parent artery occlusion and clip displacement in all cases. VR showed excellent 3D spacial relations between the clip and parent artery in 12 cases, and showed good relations in 3 cases. The 1 case with 2 clips in the pericallosal artery showed heavy beam-hardening artifacts. The size and shape of aneurysm clips were clearly depicted by MPR and thin MIP, while 3D spacial relation of aneurysm clip and parent artery were poorly showed. Conclusion: MS 3D-CTA is a safe and efficient method for the follow-up of intracranialaneurysm clipping. Combined VR with MPR or thin MIP can well reveal postoperative changes after aneurysm clipping. (authors)

  10. Troubleshooting analog circuits

    CERN Document Server

    Pease, Robert A

    1991-01-01

    Troubleshooting Analog Circuits is a guidebook for solving product or process related problems in analog circuits. The book also provides advice in selecting equipment, preventing problems, and general tips. The coverage of the book includes the philosophy of troubleshooting; the modes of failure of various components; and preventive measures. The text also deals with the active components of analog circuits, including diodes and rectifiers, optically coupled devices, solar cells, and batteries. The book will be of great use to both students and practitioners of electronics engineering. Other

  11. Modern TTL circuits manual

    CERN Document Server

    Marston, R M

    2013-01-01

    Modern TTL Circuits Manual provides an introduction to the basic principles of Transistor-Transistor Logic (TTL). This book outlines the major features of the 74 series of integrated circuits (ICs) and introduces the various sub-groups of the TTL family.Organized into seven chapters, this book begins with an overview of the basics of digital ICs. This text then examines the symbology and mathematics of digital logic. Other chapters consider a variety of topics, including waveform generator circuitry, clocked flip-flop and counter circuits, special counter/dividers, registers, data latches, com

  12. Circuit analysis with Multisim

    CERN Document Server

    Baez-Lopez, David

    2011-01-01

    This book is concerned with circuit simulation using National Instruments Multisim. It focuses on the use and comprehension of the working techniques for electrical and electronic circuit simulation. The first chapters are devoted to basic circuit analysis.It starts by describing in detail how to perform a DC analysis using only resistors and independent and controlled sources. Then, it introduces capacitors and inductors to make a transient analysis. In the case of transient analysis, it is possible to have an initial condition either in the capacitor voltage or in the inductor current, or bo

  13. Optoelectronics circuits manual

    CERN Document Server

    Marston, R M

    2013-01-01

    Optoelectronics Circuits Manual covers the basic principles and characteristics of the best known types of optoelectronic devices, as well as the practical applications of many of these optoelectronic devices. The book describes LED display circuits and LED dot- and bar-graph circuits and discusses the applications of seven-segment displays, light-sensitive devices, optocouplers, and a variety of brightness control techniques. The text also tackles infrared light-beam alarms and multichannel remote control systems. The book provides practical user information and circuitry and illustrations.

  14. 'Speedy' superconducting circuits

    International Nuclear Information System (INIS)

    Holst, T.

    1994-01-01

    The most promising concept for realizing ultra-fast superconducting digital circuits is the Rapid Single Flux Quantum (RSFQ) logic. The basic physical principle behind RSFQ logic, which include the storage and transfer of individual magnetic flux quanta in Superconducting Quantum Interference Devices (SQUIDs), is explained. A Set-Reset flip-flop is used as an example of the implementation of an RSFQ based circuit. Finally, the outlook for high-temperature superconducting materials in connection with RSFQ circuits is discussed in some details. (au)

  15. Optimizing assessment of sexual arousal in postmenopausal women using erotic film clips.

    Science.gov (United States)

    Ramos Alarcon, Lauren G; Dai, Jing; Collins, Karen; Perez, Mindy; Woodard, Terri; Diamond, Michael P

    2017-10-01

    This study sought to assess sexual arousal in a subgroup of women by identifying erotic film clips that would be most mentally appealing and physically arousing to postmenopausal women. By measuring levels of mental appeal and self-reported physical arousal using a bidirectional scale, we aimed to elucidate the clips that would best be utilized for sexual health research in the postmenopausal or over 50-year-old subpopulation. Our results showed that postmenopausal women did not rate clips with older versus younger actors differently (p>0.05). The mean mental and mean physical scores were significantly correlated for both premenopausal subject ratings (r=0.69, perotic film clips; this knowledge is relevant for design of future sexual function research. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Acute Cholangitis following Intraductal Migration of Surgical Clips 10 Years after Laparoscopic Cholecystectomy

    Directory of Open Access Journals (Sweden)

    Natalie E. Cookson

    2015-01-01

    Full Text Available Background. Laparoscopic cholecystectomy represents the gold standard approach for treatment of symptomatic gallstones. Surgery-associated complications include bleeding, bile duct injury, and retained stones. Migration of surgical clips after cholecystectomy is a rare complication and may result in gallstone formation “clip cholelithiasis”. Case Report. We report a case of a 55-year-old female patient who presented with right upper quadrant pain and severe sepsis having undergone an uncomplicated laparoscopic cholecystectomy 10 years earlier. Computed tomography (CT imaging revealed hyperdense material in the common bile duct (CBD compatible with retained calculus. Endoscopic retrograde cholangiopancreatography (ERCP revealed appearances in keeping with a migrated surgical clip within the CBD. Balloon trawl successfully extracted this, alleviating the patient’s jaundice and sepsis. Conclusion. Intraductal clip migration is a rarely encountered complication after laparoscopic cholecystectomy which may lead to choledocholithiasis. Appropriate management requires timely identification and ERCP.

  17. Longline Observer (HI & Am. Samoa) Opah Fin Clip Collection for Lampris spp. Distribution Study

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Data set containing information collected from the 1000+ fin clips collected by Hawaii & American Samoa Longline Observers that will be used to analyze the...

  18. Surgical clipping is still a good choice for the treatment of paraclinoid aneurysms

    Directory of Open Access Journals (Sweden)

    Felix Hendrik Pahl

    2016-04-01

    Full Text Available ABSTRACT Paraclinoid aneurysms are lesions located adjacent to the clinoid and ophthalmic segments of the internal carotid artery. In recent years, flow diverter stents have been introduced as a better endovascular technique for treatment of these aneurysms. Method From 2009 to 2014, a total of 43 paraclinoid aneurysms in 43 patients were surgically clipped. We retrospectively reviewed the records of these patients to analyze clinical outcomes. Results Twenty-six aneurysms (60.5% were ophthalmic artery aneurysms, while 17 were superior hypophyseal artery aneurysms (39.5%. The extradural approach to the clinoid process was used to clip these aneurysms. One hundred percent of aneurysms were clipped (complete exclusion in 100% on follow-up angiography. The length of follow-up ranged from 1 to 60 months (mean, 29.82 months. Conclusion Surgical clipping continues to be a good option for the treatment of paraclinoid aneurysms.

  19. 21 CFR 884.2685 - Fetal scalp clip electrode and applicator.

    Science.gov (United States)

    2010-04-01

    ... and an external monitoring device by means of pinching skin tissue with a nonreusable clip. This... shall have an approved PMA or a declared completed PDP in effect before being placed in commercial...

  20. Laparoscopic Filshie clip sterilization and selective use of the methylene blue dye test.

    Science.gov (United States)

    Karoshi, Mahantesh; Yoong, Wai

    2004-01-01

    In laparoscopic Filshie clip sterilization, difficulties may arise in identifying the length of the fallopian tube, with the possibility of failure of sterilization. This article describes a novel intraoperative method of demonstrating adequate tubal closure.

  1. [Choledochal lithiasis and stenosis secondary to the migration of a surgical clip].

    Science.gov (United States)

    Baldomà España, M; Pernas Canadell, J C; González Ceballos, S

    2014-01-01

    The migration of a clip to the common bile duct after cholecystectomy is an uncommon, usually late, complication that can lead to diverse complications like stone formation, stenosis, and obstruction in the bile duct. We present the case of a patient who presented with signs and symptoms of cholangitis due to clip migration one year after laparoscopic cholecystectomy; endoscopic retrograde cholangiopancreatography and biliary tract stent placement resolved the problem. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  2. Origin of fin-clipped salmonids collected at two thermal discharges on Lake Michigan

    International Nuclear Information System (INIS)

    Romberg, G.P.; Thommes, M.M.; Spigarelli, S.A.

    1974-01-01

    Fin clips observed on fish collected during tagging studies at the Point Beach and Waukegan thermal discharges were recorded and the data were tabulated by species. Using fin clip and fish size, attempts were made to identify probable stocking locations and dates from agency records. Data are presented for lake trout, rainbow trout, brown trout, and Coho salmon. Tables are presented to show probable stocking locations and dates

  3. The OTSC®-clip in revisional endoscopy against weight gain after bariatric gastric bypass surgery.

    Science.gov (United States)

    Heylen, Alex Marie Florent; Jacobs, Anja; Lybeer, Monika; Prosst, Ruediger L

    2011-10-01

    The maintenance of the restrictive component of the Fobi pouch gastric bypass is essential for permanent weight control. Dilatation of the pouch-outlet and of the pouch itself is responsible for substantial weight gain by an increased volume per meal and binge-eating due to the rapid emptying. An endoscopic over-the-scope clip (OTSC®; Ovesco AG, Tübingen, Germany) was applied in 94 patients following gastric bypass and unintended weight gain by dilated gastro-jejunostomy to narrow the pouch-outlet. The OTSC®-clip application was safe and efficient to reduce the pouch-outlet in all cases. Best clinical results were obtained by narrowing the gastro-jejunostomy by placing two clips at opposite sites, hence reducing the outlet of more than 80%. Preferably, the clip approximated the whole thickness of the wall to avoid further dilatation of the anastomosis. Between surgery and OTSC®-clip application the mean BMI dropped from 45.8 (±3.6) to 32.8 (±1.9). At the first follow-up about 3 months (mean 118 days, ±46 days) after OTSC®-clip application the mean BMI was 29.7 (±1.8). At the second follow-up about 1 year (mean 352 days, ±66 days) after OTSC®-clip application the mean BMI was 27.4 (±3.8). The OTSC®-clip for revisional endoscopy after gastric bypass is reliable and effective in treating weight gain due to a dilated pouch-outlet with favorable short- and midterm results.

  4. Preoperative simulation for the planning of microsurgical clipping of intracranial aneurysms.

    Science.gov (United States)

    Marinho, Paulo; Vermandel, Maximilien; Bourgeois, Philippe; Lejeune, Jean-Paul; Mordon, Serge; Thines, Laurent

    2014-12-01

    The safety and success of intracranial aneurysm (IA) surgery could be improved through the dedicated application of simulation covering the procedure from the 3-dimensional (3D) description of the surgical scene to the visual representation of the clip application. We aimed in this study to validate the technical feasibility and clinical relevance of such a protocol. All patients preoperatively underwent 3D magnetic resonance imaging and 3D computed tomography angiography to build 3D reconstructions of the brain, cerebral arteries, and surrounding cranial bone. These 3D models were segmented and merged using Osirix, a DICOM image processing application. This provided the surgical scene that was subsequently imported into Blender, a modeling platform for 3D animation. Digitized clips and appliers could then be manipulated in the virtual operative environment, allowing the visual simulation of clipping. This simulation protocol was assessed in a series of 10 IAs by 2 neurosurgeons. The protocol was feasible in all patients. The visual similarity between the surgical scene and the operative view was excellent in 100% of the cases, and the identification of the vascular structures was accurate in 90% of the cases. The neurosurgeons found the simulation helpful for planning the surgical approach (ie, the bone flap, cisternal opening, and arterial tree exposure) in 100% of the cases. The correct number of final clip(s) needed was predicted from the simulation in 90% of the cases. The preoperatively expected characteristics of the optimal clip(s) (ie, their number, shape, size, and orientation) were validated during surgery in 80% of the cases. This study confirmed that visual simulation of IA clipping based on the processing of high-resolution 3D imaging can be effective. This is a new and important step toward the development of a more sophisticated integrated simulation platform dedicated to cerebrovascular surgery.

  5. Endoscopic clipping for gastrointestinal tumors. A method to define the target volume more precisely

    International Nuclear Information System (INIS)

    Riepl, M.; Klautke, G.; Fehr, R.; Fietkau, R.; Pietsch, A.

    2000-01-01

    Background: In many cases it is not possible to exactly define the extension of carcinoma of the gastrointestinal tract with the help of computertomography scans made for 3-D-radiation treatment planning. Consequently, the planning of external beam radiotherapy is made more difficult for the gross tumor volume as well as, in some cases, also for the clinical target volume. Patients and Methods: Eleven patients with macrosocpic tumors (rectal cancer n = 5, cardiac cancer n = 6) were included. Just before 3-D planning, the oral and aboral border of the tumor was marked endoscopically with hemoclips. Subsequently, CT scans for radiotherapy planning were made and the clinical target volume was defined. Five to 6 weeks thereafter, new CT scans were done to define the gross tumor volume for boost planning. Two investigators independently assessed the influence of the hemoclips on the different planning volumes, and whether the number of clips was sufficient to define the gross tumor volume. Results: In all patients, the implantation of the clips was done without complications. Start of radiotherapy was not delayed. With the help of the clips it was possible to exactly define the position and the extension of the primary tumor. The clinical target volume was modified according to the position of the clips in 5/11 patients; the gross tumor volume was modified in 7/11 patients. The use of the clips made the documentation and verification of the treatment portals by the simulator easier. Moreover, the clips helped the surgeon to define the primary tumor region following marked regression after neoadjuvant therapy in 3 patients. Conclusions: Endoscopic clipping of gastrointestinal tumors helps to define the tumor volumes more precisely in radiation therapy. The clips are easily recognized on the portal films and, thus, contribute to quality control. (orig.) [de

  6. Analogue circuits simulation

    Energy Technology Data Exchange (ETDEWEB)

    Mendo, C

    1988-09-01

    Most analogue simulators have evolved from SPICE. The history and description of SPICE-like simulators are given. From a mathematical formulation of the electronic circuit the following analysis are possible: DC, AC, transient, noise, distortion, Worst Case and Statistical.

  7. Printed circuit for ATLAS

    CERN Multimedia

    Laurent Guiraud

    1999-01-01

    A printed circuit board made by scientists in the ATLAS collaboration for the transition radiaton tracker (TRT). This will read data produced when a high energy particle crosses the boundary between two materials with different electrical properties.

  8. Magnonic logic circuits

    International Nuclear Information System (INIS)

    Khitun, Alexander; Bao Mingqiang; Wang, Kang L

    2010-01-01

    We describe and analyse possible approaches to magnonic logic circuits and basic elements required for circuit construction. A distinctive feature of the magnonic circuitry is that information is transmitted by spin waves propagating in the magnetic waveguides without the use of electric current. The latter makes it possible to exploit spin wave phenomena for more efficient data transfer and enhanced logic functionality. We describe possible schemes for general computing and special task data processing. The functional throughput of the magnonic logic gates is estimated and compared with the conventional transistor-based approach. Magnonic logic circuits allow scaling down to the deep submicrometre range and THz frequency operation. The scaling is in favour of the magnonic circuits offering a significant functional advantage over the traditional approach. The disadvantages and problems of the spin wave devices are also discussed.

  9. Inducing negative affect using film clips with general and eating disorder-related content.

    Science.gov (United States)

    Koushiou, Maria; Nicolaou, Kalia; Karekla, Maria

    2018-02-09

    The aim of the present study was to select appropriate film clips with a general vs. eating disorder (ED)-related content to induce negative affect. More specifically, the study examined the subjective emotional experience (valence, arousal, anxiety, induction of somatic symptoms, and ability to control reactions during film clips) of Greek-Cypriot university students (N = 79) in response to three types of film clips: general unpleasant, ED-specific unpleasant, and emotionally neutral. In addition, the study aimed to compare the emotional reactions to the aforementioned clips between two groups of participants differing on their risk for ED (high vs. low). Preliminary results indicate the clips with general content ("The Champ") and with ED-specific content ("Binge eating") that are most effective in inducing negative affect and differentiating between risk groups. These clips provide an effective method for emotion induction that can be used for assessing the emotional experience of individuals with ED symptoms, since their emotional experience is significantly implicated in the development and maintenance of their symptoms (Merwin, Clin Psychol Sci Pract 18(3):208-214, 2011).Level of evidence No level of evidence, Experimental Study.

  10. The Use of Film Clips in a Viewing Time Task of Sexual Interests.

    Science.gov (United States)

    Lalumière, Martin L; Babchishin, Kelly M; Ebsworth, Megan

    2018-04-01

    Viewing time tasks using still pictures to assess age and gender sexual interests have been well validated and are commonly used. The use of film clips in a viewing time task would open up interesting possibilities for the study of sexual interest toward sexual targets or activities that are not easily captured in still pictures. We examined the validity of a viewing time task using film clips to assess sexual interest toward male and female targets, in a sample of 52 young adults. Film clips produced longer viewing times than still pictures. For both men and women, the indices derived from the film viewing time task were able to distinguish individuals who identified as homosexual (14 men, 8 women) from those who identified as heterosexual (15 men, 15 women), and provided comparable group differentiation as indices derived from a viewing time task using still pictures. Men's viewing times were more gender-specific than those of women. Viewing times to film clips were correlated with participants' ratings of sexual appeal of the same clips, and with viewing times to pictures. The results support the feasibility of a viewing time measure of sexual interest that utilizes film clips and, thus, expand the types of sexual interests that could be investigated (e.g., sadism, biastophilia).

  11. Anterior petroclinoid fold fenestration: an adjunct to clipping of postero-laterally projecting posterior communicating aneurysms.

    Science.gov (United States)

    Nossek, Erez; Setton, Avi; Dehdashti, Amir R; Chalif, David J

    2014-10-01

    Proximally located posterior communicating artery (PCoA) aneurysms, projecting postero-laterally in proximity to the tentorium, may pose a technical challenge for microsurgical clipping due to obscuration of the proximal aneurysmal neck by the anterior petroclinoid fold. We describe an efficacious technique utilizing fenestration of the anterior petroclinoid fold to facilitate visualization and clipping of PCoA aneurysms abutting this aspect of the tentorium. Of 86 cases of PCoA aneurysms treated between 2003 and 2013, the technique was used in nine (10.5 %) patients to allow for adequate clipping. A 3 mm fenestration in the anterior petroclinoid ligament is created adjacent and lateral to the anterior clinoid process. This fenestration is then widened into a small wedge corridor by bipolar coagulation. In all cases, the proximal aneurysm neck was visualized after the wedge fenestration. Additionally, an adequate corridor for placement of the proximal clip blade was uniformly established. All cases were adequately clipped, with complete occlusion of the aneurysm neck and fundus with preservation of the PCoA. There were two intraoperative ruptures not related to creation of the wedge fenestration. One patient experienced post-operative partial third nerve palsy, which resolved during follow-up. We describe a technique of fenestration of the anterior petroclinoid fold to establish a critical and safe corridor for both visualization and clipping of PCoA aneurysms.

  12. The effect of music video clips on adolescent boys' body image, mood, and schema activation.

    Science.gov (United States)

    Mulgrew, Kate E; Volcevski-Kostas, Diana; Rendell, Peter G

    2014-01-01

    There is limited research that has examined experimentally the effects of muscular images on adolescent boys' body image, with no research specifically examining the effects of music television. The aim of the current study was to examine the effects of viewing muscular and attractive singers in music video clips on early, mid, and late adolescent boys' body image, mood, and schema activation. Participants were 180 boys in grade 7 (mean age = 12.73 years), grade 9 (mean age = 14.40 years) or grade 11 (mean age = 16.15 years) who completed pre- and post-test measures of mood and body satisfaction after viewing music videos containing male singers of muscular or average appearance. They also completed measures of schema activation and social comparison after viewing the clips. The results showed that the boys who viewed the muscular clips reported poorer upper body satisfaction, lower appearance satisfaction, lower happiness, and more depressive feelings compared to boys who viewed the clips depicting singers of average appearance. There was no evidence of increased appearance schema activation but the boys who viewed the muscular clips did report higher levels of social comparison to the singers. The results suggest that music video clips are a powerful form of media in conveying information about the male ideal body shape and that negative effects are found in boys as young as 12 years.

  13. Impact of Clipping versus Coiling on Postoperative Hemodynamics and Pulmonary Edema after Subarachnoid Hemorrhage

    Directory of Open Access Journals (Sweden)

    Nobutaka Horie

    2014-01-01

    Full Text Available Volume management is critical for assessment of cerebral vasospasm after aneurysmal subarachnoid hemorrhage (SAH. This multicenter prospective cohort study compared the impact of surgical clipping versus endovascular coiling on postoperative hemodynamics and pulmonary edema in patients with SAH. Hemodynamic parameters were measured for 14 days using a transpulmonary thermodilution system. The study included 202 patients, including 160 who underwent clipping and 42 who underwent coiling. There were no differences in global ejection fraction (GEF, cardiac index, systemic vascular resistance index, or global end-diastolic volume index between the clipping and coiling groups in the early period. However, extravascular lung water index (EVLWI and pulmonary vascular permeability index (PVPI were significantly higher in the clipping group in the vasospasm period. Postoperative C-reactive protein (CRP level was higher in the clipping group and was significantly correlated with postoperative brain natriuretic peptide level. Multivariate analysis found that PVPI and GEF were independently associated with high EVLWI in the early period, suggesting cardiogenic edema, and that CRP and PVPI, but not GEF, were independently associated with high EVLWI in the vasospasm period, suggesting noncardiogenic edema. In conclusion, clipping affects postoperative CRP level and may thereby increase noncardiogenic pulmonary edema in the vasospasm period. His trial is registered with University Hospital Medical Information Network UMIN000003794.

  14. Anticipation of high arousal aversive and positive movie clips engages common and distinct neural substrates.

    Science.gov (United States)

    Greenberg, Tsafrir; Carlson, Joshua M; Rubin, Denis; Cha, Jiook; Mujica-Parodi, Lilianne

    2015-04-01

    The neural correlates of anxious anticipation have been primarily studied with aversive and neutral stimuli. In this study, we examined the effect of valence on anticipation by using high arousal aversive and positive stimuli and a condition of uncertainty (i.e. either positive or aversive). The task consisted of predetermined cues warning participants of upcoming aversive, positive, 'uncertain' (either aversive or positive) and neutral movie clips. Anticipation of all affective clips engaged common regions including the anterior insula, dorsal anterior cingulate cortex, thalamus, caudate, inferior parietal and prefrontal cortex that are associated with emotional experience, sustained attention and appraisal. In contrast, the nucleus accumbens and medial prefrontal cortex, regions implicated in reward processing, were selectively engaged during anticipation of positive clips (depicting sexually explicit content) and the mid-insula, which has been linked to processing aversive stimuli, was selectively engaged during anticipation of aversive clips (depicting graphic medical procedures); these three areas were also activated during anticipation of 'uncertain' clips reflecting a broad preparatory response for both aversive and positive stimuli. These results suggest that a common circuitry is recruited in anticipation of affective clips regardless of valence, with additional areas preferentially engaged depending on whether expected stimuli are negative or positive. © The Author (2014). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  15. Microsurgery Simulator of Cerebral Aneurysm Clipping with Interactive Cerebral Deformation Featuring a Virtual Arachnoid.

    Science.gov (United States)

    Shono, Naoyuki; Kin, Taichi; Nomura, Seiji; Miyawaki, Satoru; Saito, Toki; Imai, Hideaki; Nakatomi, Hirofumi; Oyama, Hiroshi; Saito, Nobuhito

    2018-05-01

    A virtual reality simulator for aneurysmal clipping surgery is an attractive research target for neurosurgeons. Brain deformation is one of the most important functionalities necessary for an accurate clipping simulator and is vastly affected by the status of the supporting tissue, such as the arachnoid membrane. However, no virtual reality simulator implementing the supporting tissue of the brain has yet been developed. To develop a virtual reality clipping simulator possessing interactive brain deforming capability closely dependent on arachnoid dissection and apply it to clinical cases. Three-dimensional computer graphics models of cerebral tissue and surrounding structures were extracted from medical images. We developed a new method for modifiable cerebral tissue complex deformation by incorporating a nonmedical image-derived virtual arachnoid/trabecula in a process called multitissue integrated interactive deformation (MTIID). MTIID made it possible for cerebral tissue complexes to selectively deform at the site of dissection. Simulations for 8 cases of actual clipping surgery were performed before surgery and evaluated for their usefulness in surgical approach planning. Preoperatively, each operative field was precisely reproduced and visualized with the virtual brain retraction defined by users. The clear visualization of the optimal approach to treating the aneurysm via an appropriate arachnoid incision was possible with MTIID. A virtual clipping simulator mainly focusing on supporting tissues and less on physical properties seemed to be useful in the surgical simulation of cerebral aneurysm clipping. To our knowledge, this article is the first to report brain deformation based on supporting tissues.

  16. Heavy metal phytoextraction by Sedum alfredii is affected by continual clipping and phosphorus fertilization amendment.

    Science.gov (United States)

    Huang, Huagang; Li, Tingqiang; Gupta, D K; He, Zhenli; Yang, Xiao-E; Ni, Bingnan; Li, Mao

    2012-01-01

    Improving the efficacy of phytoextraction is critical for its successful application in metal contaminated soils. Mineral nutrition affects plant growth and metal absorption and subsequently the accumulation of heavy metal through hyper-accumulator plants. This study assessed the effects of di-hydrogen phosphates (KH2PO4, Ca(H2PO4)2, NaH2PO4 and NH4H2PO4) application at three levels (22, 88 and 352 mg P/kg soil) on Sedum alfredii growth and metal uptake by three consecutive harvests on aged and Zn/Cd combined contaminated paddy soil. The addition of phosphates (P) significantly increased the amount of Zn taken up by S. alfredii due to increased shoot Zn concentration and dry matter yield (DMY) (P phytoextraction of Zn and Cd was observed in KH2PO4 and NH4H2PO4 treatment at 352 mg P/kg soil. The amount of Zn removed by phytoextraction increased in the order of 1st clipping < 2nd clipping < 3rd clipping, and for Cd extraction the order was 2nd clipping < 1st clipping < 3rd clipping. These results indicate that the application of P fertilizers coupled with multiple cuttings can enhance the removal of Zn and Cd from contaminated soils by S. alfredii, thus shortening the time needed for accomplishing remediation goals.

  17. Magnetic resonance angiography with ultrashort echo times reduces the artefact of aneurysm clips

    International Nuclear Information System (INIS)

    Goenner, F.; Heid, O.; Remonda, L.; Schroth, G.; Loevblad, K.O.; Guzman, R.; Barth, A.

    2002-01-01

    We evaluated the ability of an ultrashort echo time (TE) three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) sequence to reduce the metal artefact of intracranial aneurysm clips and to display adjacent cerebral arteries. In five patients (aged 8-72 years) treated with Elgiloy or Phynox aneurysm clips we prospectively performed a conventional (TE 6.0 ms) and a new ultrashort TE (TE 2.4 ms) 3D TOF MRA. We compared the diameter of the clip-induced susceptibility artefact and the detectability of flow in adjacent vessels. The mean artefact diameter was 22.3±6.4 mm (range 14-38 mm) with the ultrashort TE and 27.7±6.4 mm (range 19-45 mm) with the conventional MRA (P<0.0001). This corresponded to a diameter reduction of 19.5±9.2%. More parts of adjacent vessels were detected, but with less intense flow signal. The aneurysm dome and neck remained within the area of signal loss and were therefore not displayed. Ultrashort TE MRA is a noninvasive and fast method for improving detection of vessels adjacent to clipped intracranial aneurysms, by reducing clip-induced susceptibility artefact. The method cannot, however, be used to show remnants of the aneurysm neck or sac as a result of imperfect clipping. (orig.)

  18. Peak reading detector circuit

    International Nuclear Information System (INIS)

    Courtin, E.; Grund, K.; Traub, S.; Zeeb, H.

    1975-01-01

    The peak reading detector circuit serves for picking up the instants during which peaks of a given polarity occur in sequences of signals in which the extreme values, their time intervals, and the curve shape of the signals vary. The signal sequences appear in measuring the foetal heart beat frequence from amplitude-modulated ultrasonic, electrocardiagram, and blood pressure signals. In order to prevent undesired emission of output signals from, e. g., disturbing intermediate extreme values, the circuit consists of the series connections of a circuit to simulate an ideal diode, a strong unit, a discriminator for the direction of charging current, a time-delay circuit, and an electronic switch lying in the decharging circuit of the storage unit. The time-delay circuit thereby causes storing of a preliminary maximum value being used only after a certain time delay for the emission of the output signal. If a larger extreme value occurs during the delay time the preliminary maximum value is cleared and the delay time starts running anew. (DG/PB) [de

  19. Color Coding of Circuit Quantities in Introductory Circuit Analysis Instruction

    Science.gov (United States)

    Reisslein, Jana; Johnson, Amy M.; Reisslein, Martin

    2015-01-01

    Learning the analysis of electrical circuits represented by circuit diagrams is often challenging for novice students. An open research question in electrical circuit analysis instruction is whether color coding of the mathematical symbols (variables) that denote electrical quantities can improve circuit analysis learning. The present study…

  20. Project Circuits in a Basic Electric Circuits Course

    Science.gov (United States)

    Becker, James P.; Plumb, Carolyn; Revia, Richard A.

    2014-01-01

    The use of project circuits (a photoplethysmograph circuit and a simple audio amplifier), introduced in a sophomore-level electric circuits course utilizing active learning and inquiry-based methods, is described. The development of the project circuits was initiated to promote enhanced engagement and deeper understanding of course content among…

  1. Biochemical Analysis Reveals the Multifactorial Mechanism of Histone H3 Clipping by Chicken Liver Histone H3 Protease

    KAUST Repository

    Chauhan, Sakshi

    2016-09-02

    Proteolytic clipping of histone H3 has been identified in many organisms. Despite several studies, the mechanism of clipping, the substrate specificity, and the significance of this poorly understood epigenetic mechanism are not clear. We have previously reported histone H3 specific proteolytic clipping and a protein inhibitor in chicken liver. However, the sites of clipping are still not known very well. In this study, we attempt to identify clipping sites in histone H3 and to determine the mechanism of inhibition by stefin B protein, a cysteine protease inhibitor. By employing site-directed mutagenesis and in vitro biochemical assays, we have identified three distinct clipping sites in recombinant human histone H3 and its variants (H3.1, H3.3, and H3t). However, post-translationally modified histones isolated from chicken liver and Saccharomyces cerevisiae wild-type cells showed different clipping patterns. Clipping of histone H3 N-terminal tail at three sites occurs in a sequential manner. We have further observed that clipping sites are regulated by the structure of the N-terminal tail as well as the globular domain of histone H3. We also have identified the QVVAG region of stefin B protein to be very crucial for inhibition of the protease activity. Altogether, our comprehensive biochemical studies have revealed three distinct clipping sites in histone H3 and their regulation by the structure of histone H3, histone modifications marks, and stefin B.

  2. A comparison of two endoscopic closures: over-the-scope clip (OTSC) versus KING closure (endoloop plus clips) in a randomized long-term experimental study

    Czech Academy of Sciences Publication Activity Database

    Doležel, R.; Ryska, O.; Kollár, M.; Juhásová, Jana; Kalvach, J.; Ryska, M.; Martínek, J.

    2016-01-01

    Roč. 30, č. 11 (2016), s. 4910-4916 ISSN 0930-2794 R&D Projects: GA MZd(CZ) NT13634; GA MŠk ED2.1.00/03.0124 Institutional support: RVO:67985904 Keywords : NOTES * endoscopic closure * KING closure * over-the-scope clip Subject RIV: FJ - Surgery incl. Transplants Impact factor: 3.747, year: 2016

  3. Low latency asynchronous interface circuits

    Science.gov (United States)

    Sadowski, Greg

    2017-06-20

    In one form, a logic circuit includes an asynchronous logic circuit, a synchronous logic circuit, and an interface circuit coupled between the asynchronous logic circuit and the synchronous logic circuit. The asynchronous logic circuit has a plurality of asynchronous outputs for providing a corresponding plurality of asynchronous signals. The synchronous logic circuit has a plurality of synchronous inputs corresponding to the plurality of asynchronous outputs, a stretch input for receiving a stretch signal, and a clock output for providing a clock signal. The synchronous logic circuit provides the clock signal as a periodic signal but prolongs a predetermined state of the clock signal while the stretch signal is active. The asynchronous interface detects whether metastability could occur when latching any of the plurality of the asynchronous outputs of the asynchronous logic circuit using said clock signal, and activates the stretch signal while the metastability could occur.

  4. Fabrication and Characterization of ZnO Nano-Clips by the Polyol-Mediated Process.

    Science.gov (United States)

    Wang, Mei; Li, Ai-Dong; Kong, Ji-Zhou; Gong, You-Pin; Zhao, Chao; Tang, Yue-Feng; Wu, Di

    2018-02-09

    ZnO nano-clips with better monodispersion were prepared successfully using zinc acetate hydrate (Zn(OAc) 2 ·nH 2 O) as Zn source and ethylene glycol (EG) as solvent by a simple solution-based route-polyol process. The effect of solution concentration on the formation of ZnO nano-clips has been investigated deeply. We first prove that the 0.01 M Zn(OAc) 2 ·nH 2 O can react with EG without added water or alkaline, producing ZnO nano-clips with polycrystalline wurtzite structure at 170 °C. As-synthesized ZnO nano-clips contain a lot of aggregated nanocrystals (~ 5 to 15 nm) with high specific surface area of 88 m 2 /g. The shapes of ZnO nano-clips basically keep constant with improved crystallinity after annealing at 400-600 °C. The lower solution concentration and slight amount of H 2 O play a decisive role in ZnO nano-clip formation. When the solution concentration is ≤ 0.0125 M, the complexing and polymerization reactions between Zn(OAc) 2 ·nH 2 O and EG predominate, mainly elaborating ZnO nano-clips. When the solution concentration is ≥ 0.015 M, the alcoholysis and polycondensation reactions of Zn(OAc) 2 ·nH 2 O and EG become dominant, leading to ZnO particle formation with spherical and elliptical shapes. The possible growth mechanism based on a competition between complexing and alcoholysis of Zn(OAc) 2 ·nH 2 O and EG has been proposed.

  5. Fabrication and Characterization of ZnO Nano-Clips by the Polyol-Mediated Process

    Science.gov (United States)

    Wang, Mei; Li, Ai-Dong; Kong, Ji-Zhou; Gong, You-Pin; Zhao, Chao; Tang, Yue-Feng; Wu, Di

    2018-02-01

    ZnO nano-clips with better monodispersion were prepared successfully using zinc acetate hydrate (Zn(OAc)2·nH2O) as Zn source and ethylene glycol (EG) as solvent by a simple solution-based route-polyol process. The effect of solution concentration on the formation of ZnO nano-clips has been investigated deeply. We first prove that the 0.01 M Zn(OAc)2·nH2O can react with EG without added water or alkaline, producing ZnO nano-clips with polycrystalline wurtzite structure at 170 °C. As-synthesized ZnO nano-clips contain a lot of aggregated nanocrystals ( 5 to 15 nm) with high specific surface area of 88 m2/g. The shapes of ZnO nano-clips basically keep constant with improved crystallinity after annealing at 400-600 °C. The lower solution concentration and slight amount of H2O play a decisive role in ZnO nano-clip formation. When the solution concentration is ≤ 0.0125 M, the complexing and polymerization reactions between Zn(OAc)2·nH2O and EG predominate, mainly elaborating ZnO nano-clips. When the solution concentration is ≥ 0.015 M, the alcoholysis and polycondensation reactions of Zn(OAc)2·nH2O and EG become dominant, leading to ZnO particle formation with spherical and elliptical shapes. The possible growth mechanism based on a competition between complexing and alcoholysis of Zn(OAc)2·nH2O and EG has been proposed.

  6. Nonvariceal Upper Gastrointestinal Bleeding: the Usefulness of Rotational Angiography after Endoscopic Marking with a Metallic Clip

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ji Soo; Kwak, Hyo Sung; Chung, Gyung Ho [Chonbuk National University Medical School, Chonju (Korea, Republic of)

    2011-08-15

    We wanted to assess the usefulness of rotational angiography after endoscopic marking with a metallic clip in upper gastrointestinal bleeding patients with no extravasation of contrast medium on conventional angiography. In 16 patients (mean age, 59.4 years) with acute bleeding ulcers (13 gastric ulcers, 2 duodenal ulcers, 1 malignant ulcer), a metallic clip was placed via gastroscopy and this had been preceded by routine endoscopic treatment. The metallic clip was placed in the fibrous edge of the ulcer adjacent to the bleeding point. All patients had negative results from their angiographic studies. To localize the bleeding focus, rotational angiography and high pressure angiography as close as possible to the clip were used. Of the 16 patients, seven (44%) had positive results after high pressure angiography as close as possible to the clip and they underwent transcatheter arterial embolization (TAE) with microcoils. Nine patients without extravasation of contrast medium underwent TAE with microcoils as close as possible to the clip. The bleeding was stopped initially in all patients after treatment of the feeding artery. Two patients experienced a repeat episode of bleeding two days later. Of the two patients, one had subtle oozing from the ulcer margin and that patient underwent endoscopic treatment. One patient with malignant ulcer died due to disseminated intravascular coagulation one month after embolization. Complete clinical success was achieved in 14 of 16 (88%) patients. Delayed bleeding or major/minor complications were not noted. Rotational angiography after marking with a metallic clip helps to localize accurately the bleeding focus and thus to embolize the vessel correctly.

  7. Nonvariceal Upper Gastrointestinal Bleeding: the Usefulness of Rotational Angiography after Endoscopic Marking with a Metallic Clip

    International Nuclear Information System (INIS)

    Song, Ji Soo; Kwak, Hyo Sung; Chung, Gyung Ho

    2011-01-01

    We wanted to assess the usefulness of rotational angiography after endoscopic marking with a metallic clip in upper gastrointestinal bleeding patients with no extravasation of contrast medium on conventional angiography. In 16 patients (mean age, 59.4 years) with acute bleeding ulcers (13 gastric ulcers, 2 duodenal ulcers, 1 malignant ulcer), a metallic clip was placed via gastroscopy and this had been preceded by routine endoscopic treatment. The metallic clip was placed in the fibrous edge of the ulcer adjacent to the bleeding point. All patients had negative results from their angiographic studies. To localize the bleeding focus, rotational angiography and high pressure angiography as close as possible to the clip were used. Of the 16 patients, seven (44%) had positive results after high pressure angiography as close as possible to the clip and they underwent transcatheter arterial embolization (TAE) with microcoils. Nine patients without extravasation of contrast medium underwent TAE with microcoils as close as possible to the clip. The bleeding was stopped initially in all patients after treatment of the feeding artery. Two patients experienced a repeat episode of bleeding two days later. Of the two patients, one had subtle oozing from the ulcer margin and that patient underwent endoscopic treatment. One patient with malignant ulcer died due to disseminated intravascular coagulation one month after embolization. Complete clinical success was achieved in 14 of 16 (88%) patients. Delayed bleeding or major/minor complications were not noted. Rotational angiography after marking with a metallic clip helps to localize accurately the bleeding focus and thus to embolize the vessel correctly.

  8. Iterative Signal Processing for Mitigation of Analog-to-Digital Converter Clipping Distortion in Multiband OFDMA Receivers

    Directory of Open Access Journals (Sweden)

    Markus Allén

    2012-01-01

    Full Text Available In modern wideband communication receivers, the large input-signal dynamics is a fundamental problem. Unintentional signal clipping occurs, if the receiver front-end with the analog-to-digital interface cannot respond to rapidly varying conditions. This paper discusses digital postprocessing compensation of such unintentional clipping in multiband OFDMA receivers. The proposed method iteratively mitigates the clipping distortion by exploiting the symbol decisions. The performance of the proposed method is illustrated with various computer simulations and also verified by concrete laboratory measurements with commercially available analog-to-digital hardware. It is shown that the clipping compensation algorithm implemented in a turbo decoding OFDM receiver is able to remove almost all the clipping distortion even under significant clipping in fading channel circumstances. That is to say, it is possible to nearly recover the receiver performance to the level, which would be achieved in the equivalent nonclipped situation.

  9. Junction and circuit fabrication

    International Nuclear Information System (INIS)

    Jackel, L.D.

    1980-01-01

    Great strides have been made in Josephson junction fabrication in the four years since the first IC SQUID meeting. Advances in lithography have allowed the production of devices with planar dimensions as small as a few hundred angstroms. Improved technology has provided ultra-high sensitivity SQUIDS, high-efficiency low-noise mixers, and complex integrated circuits. This review highlights some of the new fabrication procedures. The review consists of three parts. Part 1 is a short summary of the requirements on junctions for various applications. Part 2 reviews intergrated circuit fabrication, including tunnel junction logic circuits made at IBM and Bell Labs, and microbridge radiation sources made at SUNY at Stony Brook. Part 3 describes new junction fabrication techniques, the major emphasis of this review. This part includes a discussion of small oxide-barrier tunnel junctions, semiconductor barrier junctions, and microbridge junctions. Part 3 concludes by considering very fine lithography and limitations to miniaturization. (orig.)

  10. A superconducting supercollider calorimeter photomultiplier tube preamplifier circuit

    Energy Technology Data Exchange (ETDEWEB)

    Panescu, D; Lackey, J; Robl, P; Smith, W H [Wisconsin Univ., Madison, WI (United States). Physics Dept.

    1992-07-15

    This study presents the design of the front end amplifier for a scintillator calorimeter with photomultiplier tube (PMT) readout. The design is based on analytical computations and SPICE simulations, and is checked against tests performed on a prototyped circuit. We were looking to achieve (1) a very low droop within the 4 ns after the integration of the photomultiplier tube (PMT) signal was completed, (2) a very low noise figure for the whole amplifier in a 100 MHz bandwidth, (3) an input impedance optimized for the PMT which is actually used, (4) baseline restoration as quick as possible at the output of the clip amps, (5) no loss of information due to the saturation at intermediary stages (e.g. integrator), and (6) an output driving 100 {Omega} twisted pair cables, or 50 {Omega} coaxial cables, in order to transmit the signal to switched capacitor arrays for analog storage. (orig.).

  11. Small circuits for cryptography.

    Energy Technology Data Exchange (ETDEWEB)

    Torgerson, Mark Dolan; Draelos, Timothy John; Schroeppel, Richard Crabtree; Miller, Russell D.; Anderson, William Erik

    2005-10-01

    This report examines a number of hardware circuit design issues associated with implementing certain functions in FPGA and ASIC technologies. Here we show circuit designs for AES and SHA-1 that have an extremely small hardware footprint, yet show reasonably good performance characteristics as compared to the state of the art designs found in the literature. Our AES performance numbers are fueled by an optimized composite field S-box design for the Stratix chipset. Our SHA-1 designs use register packing and feedback functionalities of the Stratix LE, which reduce the logic element usage by as much as 72% as compared to other SHA-1 designs.

  12. Silicon integrated circuit process

    International Nuclear Information System (INIS)

    Lee, Jong Duck

    1985-12-01

    This book introduces the process of silicon integrated circuit. It is composed of seven parts, which are oxidation process, diffusion process, ion implantation process such as ion implantation equipment, damage, annealing and influence on manufacture of integrated circuit and device, chemical vapor deposition process like silicon Epitaxy LPCVD and PECVD, photolithography process, including a sensitizer, spin, harden bake, reflection of light and problems related process, infrared light bake, wet-etch, dry etch, special etch and problems of etching, metal process like metal process like metal-silicon connection, aluminum process, credibility of aluminum and test process.

  13. Primer printed circuit boards

    CERN Document Server

    Argyle, Andrew

    2009-01-01

    Step-by-step instructions for making your own PCBs at home. Making your own printed circuit board (PCB) might seem a daunting task, but once you master the steps, it's easy to attain professional-looking results. Printed circuit boards, which connect chips and other components, are what make almost all modern electronic devices possible. PCBs are made from sheets of fiberglass clad with copper, usually in multiplelayers. Cut a computer motherboard in two, for instance, and you'll often see five or more differently patterned layers. Making boards at home is relatively easy

  14. Silicon integrated circuit process

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Duck

    1985-12-15

    This book introduces the process of silicon integrated circuit. It is composed of seven parts, which are oxidation process, diffusion process, ion implantation process such as ion implantation equipment, damage, annealing and influence on manufacture of integrated circuit and device, chemical vapor deposition process like silicon Epitaxy LPCVD and PECVD, photolithography process, including a sensitizer, spin, harden bake, reflection of light and problems related process, infrared light bake, wet-etch, dry etch, special etch and problems of etching, metal process like metal process like metal-silicon connection, aluminum process, credibility of aluminum and test process.

  15. Circuit design for reliability

    CERN Document Server

    Cao, Yu; Wirth, Gilson

    2015-01-01

    This book presents physical understanding, modeling and simulation, on-chip characterization, layout solutions, and design techniques that are effective to enhance the reliability of various circuit units.  The authors provide readers with techniques for state of the art and future technologies, ranging from technology modeling, fault detection and analysis, circuit hardening, and reliability management. Provides comprehensive review on various reliability mechanisms at sub-45nm nodes; Describes practical modeling and characterization techniques for reliability; Includes thorough presentation of robust design techniques for major VLSI design units; Promotes physical understanding with first-principle simulations.

  16. Electronic circuits fundamentals & applications

    CERN Document Server

    Tooley, Mike

    2015-01-01

    Electronics explained in one volume, using both theoretical and practical applications.New chapter on Raspberry PiCompanion website contains free electronic tools to aid learning for students and a question bank for lecturersPractical investigations and questions within each chapter help reinforce learning Mike Tooley provides all the information required to get to grips with the fundamentals of electronics, detailing the underpinning knowledge necessary to appreciate the operation of a wide range of electronic circuits, including amplifiers, logic circuits, power supplies and oscillators. The

  17. Psychiatric disorder associated with vacuum-assisted breast biopsy clip placement: a case report

    Directory of Open Access Journals (Sweden)

    Zografos George C

    2008-10-01

    Full Text Available Abstract Introduction Vacuum-assisted breast biopsy is a minimally invasive technique that has been used increasingly in the treatment of mammographically detected, non-palpable breast lesions. Clip placement at the biopsy site is standard practice after vacuum-assisted breast biopsy. Case presentation We present the case of a 62-year-old woman with suspicious microcalcifications in her left breast. The patient was informed about vacuum-assisted breast biopsy, including clip placement. During the course of taking the patient's history, she communicated excellently, her demeanor was normal, she disclosed no intake of psychiatric medication and had not been diagnosed with any psychiatric disorders. Subsequently, the patient underwent vacuum-assisted breast biopsy (11 G under local anesthesia. A clip was placed at the biopsy site. The pathological diagnosis was of sclerosing adenosis. At the 6-month mammographic follow-up, the radiologist mentioned the existence of the metallic clip in her breast. Subsequently, the woman presented complaining about "being spied [upon] by an implanted clip in [her] breast" and repeatedly requested the removal of the clip. The patient was referred to the specialized psychiatrist of our breast unit for evaluation. The Mental State Examination found that systematized paranoid ideas of persecutory type dominated her daily routines. At the time, she believed that the implanted clip was one of several pieces of equipment being used to keep her under surveillance, the other equipment being her telephone, cameras and television. Quite surprisingly, she had never had a consultation with a mental health professional. The patient appeared depressed and her insight into her condition was impaired. The prevalent diagnosis was schizotypal disorder, whereas the differential diagnosis comprised delusional disorder of persecutory type, affective disorder with psychotic features or comorbid delusional disorder with major depression

  18. Effects of Milrinone continuous intravenous infusion on global cerebral oxygenation and cerebral vasospasm after cerebral aneurysm surgical clipping

    Directory of Open Access Journals (Sweden)

    Mohamed A. Ghanem

    2014-01-01

    Conclusions: Milrinone improved significantly the global cerebral oxygenation and reduced the incidence of cerebral vasospasm during the dangerous period of cerebral spasm after cerebral aneurysm clipping.

  19. It is time for a better clip applier - 3 mm, percutaneous, non-crushing and locking.

    Science.gov (United States)

    Yuval, Jonathan B; Weiss, Daniel J; Paz, Adrian; Bachar, Yehuda; Brodie, Ronit; Shapira, Yinon; Mintz, Yoav

    2017-10-06

    Since the advent of laparoscopy there have been attempts to minimize abdominal wall incisions. For this purpose smaller instruments have been produced. Our aim was to develop the first 3 mm percutaneous clip applier and to make it better than the standard clips of today. The ClipTip clip is made of Nitinol and has a crocodile shaped jaws, which when apposed effectively seal vessels. The shaft operates as a retractable needle permitting percutaneous insertion. Closing, reopening and reclosing is possible. The physical properties of the device were compared to three commercially available clip appliers. Surgeries were performed on porcine animals by experienced surgeons. In comparison to available clips, the superiority of the ClipTip is a combination of wide effective length alongside the ability to withstand strong forces. In live animal studies the Cliptip was inserted into the peritoneal cavity without any injuries. Vessels were ligated successfully and no clip dislodgement or leakage occurred. We developed the next generation clip applier with better properties. Advantages include its length, the needleoscopic caliber, non-crushing effect, locking mechanism and wide aperture. The device has performed safely and effectively in pre-clinical tests. Further studies are planned in humans.

  20. Peak reduction and clipping mitigation in OFDM by augmented compressive sensing

    KAUST Repository

    Al-Safadi, Ebrahim B.

    2012-07-01

    This work establishes the design, analysis, and fine-tuning of a peak-to-average-power-ratio (PAPR) reducing system, based on compressed sensing (CS) at the receiver of a peak-reducing sparse clipper applied to an orthogonal frequency-division multiplexing (OFDM) signal at the transmitter. By exploiting the sparsity of clipping events in the time domain relative to a predefined clipping threshold, the method depends on partially observing the frequency content of the clipping distortion over reserved tones to estimate the remaining distortion. The approach has the advantage of eliminating the computational complexity at the transmitter and reducing the overall complexity of the system compared to previous methods which incorporate pilots to cancel nonlinear distortion. Data-based augmented CS methods are also proposed that draw upon available phase and support information from data tones for enhanced estimation and cancelation of clipping noise. This enables signal recovery under more severe clipping scenarios and hence lower PAPR can be achieved compared to conventional CS techniques. © 2012 IEEE.

  1. Peak reduction and clipping mitigation in OFDM by augmented compressive sensing

    KAUST Repository

    Al-Safadi, Ebrahim B.; Al-Naffouri, Tareq Y.

    2012-01-01

    This work establishes the design, analysis, and fine-tuning of a peak-to-average-power-ratio (PAPR) reducing system, based on compressed sensing (CS) at the receiver of a peak-reducing sparse clipper applied to an orthogonal frequency-division multiplexing (OFDM) signal at the transmitter. By exploiting the sparsity of clipping events in the time domain relative to a predefined clipping threshold, the method depends on partially observing the frequency content of the clipping distortion over reserved tones to estimate the remaining distortion. The approach has the advantage of eliminating the computational complexity at the transmitter and reducing the overall complexity of the system compared to previous methods which incorporate pilots to cancel nonlinear distortion. Data-based augmented CS methods are also proposed that draw upon available phase and support information from data tones for enhanced estimation and cancelation of clipping noise. This enables signal recovery under more severe clipping scenarios and hence lower PAPR can be achieved compared to conventional CS techniques. © 2012 IEEE.

  2. Harmonic Scalpel versus electrocautery and surgical clips in head and neck free-flap harvesting.

    Science.gov (United States)

    Dean, Nichole R; Rosenthal, Eben L; Morgan, Bruce A; Magnuson, J Scott; Carroll, William R

    2014-06-01

    We sought to determine the safety and utility of Harmonic Scalpel-assisted free-flap harvesting as an alternative to a combined electrocautery and surgical clip technique. The medical records of 103 patients undergoing radial forearm free-flap reconstruction (105 free flaps) for head and neck surgical defects between 2006 and 2008 were reviewed. The use of bipolar electrocautery and surgical clips for division of small perforating vessels (n = 53) was compared to ultrasonic energy (Harmonic Scalpel; Ethicon Endo-Surgery, Inc., Cincinnati, Ohio) (n = 52) free-tissue harvesting techniques. Flap-harvesting time was reduced with the use of the Harmonic Scalpel when compared with electrocautery and surgical clip harvest (31.4 vs. 36.9 minutes, respectively; p = 0.06). Two patients who underwent flap harvest with electrocautery and surgical clips developed postoperative donor site hematomas, whereas no donor site complications were noted in the Harmonic Scalpel group. Recipient site complication rates for infection, fistula, and hematoma were similar for both harvesting techniques (p = 0.77). Two flap failures occurred in the clip-assisted radial forearm free-flap harvest group, and none in the Harmonic Scalpel group. Median length of hospitalization was significantly reduced for patients who underwent free-flap harvest with the Harmonic Scalpel when compared with the other technique (7 vs. 8 days; p = 0.01). The Harmonic Scalpel is safe, and its use is feasible for radial forearm free-flap harvest.

  3. ESD analog circuits and design

    CERN Document Server

    Voldman, Steven H

    2014-01-01

    A comprehensive and in-depth review of analog circuit layout, schematic architecture, device, power network and ESD design This book will provide a balanced overview of analog circuit design layout, analog circuit schematic development, architecture of chips, and ESD design.  It will start at an introductory level and will bring the reader right up to the state-of-the-art. Two critical design aspects for analog and power integrated circuits are combined. The first design aspect covers analog circuit design techniques to achieve the desired circuit performance. The second and main aspect pres

  4. Unstable oscillators based hyperchaotic circuit

    DEFF Research Database (Denmark)

    Murali, K.; Tamasevicius, A.; G. Mykolaitis, A.

    1999-01-01

    A simple 4th order hyperchaotic circuit with unstable oscillators is described. The circuit contains two negative impedance converters, two inductors, two capacitors, a linear resistor and a diode. The Lyapunov exponents are presented to confirm hyperchaotic nature of the oscillations in the circ...... in the circuit. The performance of the circuit is investigated by means of numerical integration of appropriate differential equations, PSPICE simulations, and hardware experiment.......A simple 4th order hyperchaotic circuit with unstable oscillators is described. The circuit contains two negative impedance converters, two inductors, two capacitors, a linear resistor and a diode. The Lyapunov exponents are presented to confirm hyperchaotic nature of the oscillations...

  5. The test of VLSI circuits

    Science.gov (United States)

    Baviere, Ph.

    Tests which have proven effective for evaluating VLSI circuits for space applications are described. It is recommended that circuits be examined after each manfacturing step to gain fast feedback on inadequacies in the production system. Data from failure modes which occur during operational lifetimes of circuits also permit redefinition of the manufacturing and quality control process to eliminate the defects identified. Other tests include determination of the operational envelope of the circuits, examination of the circuit response to controlled inputs, and the performance and functional speeds of ROM and RAM memories. Finally, it is desirable that all new circuits be designed with testing in mind.

  6. Electronic Circuit Analysis Language (ECAL)

    Science.gov (United States)

    Chenghang, C.

    1983-03-01

    The computer aided design technique is an important development in computer applications and it is an important component of computer science. The special language for electronic circuit analysis is the foundation of computer aided design or computer aided circuit analysis (abbreviated as CACD and CACA) of simulated circuits. Electronic circuit analysis language (ECAL) is a comparatively simple and easy to use circuit analysis special language which uses the FORTRAN language to carry out the explanatory executions. It is capable of conducting dc analysis, ac analysis, and transient analysis of a circuit. Futhermore, the results of the dc analysis can be used directly as the initial conditions for the ac and transient analyses.

  7. An integrated circuit switch

    Science.gov (United States)

    Bonin, E. L.

    1969-01-01

    Multi-chip integrated circuit switch consists of a GaAs photon-emitting diode in close proximity with S1 phototransistor. A high current gain is obtained when the transistor has a high forward common-emitter current gain.

  8. Automatic sweep circuit

    International Nuclear Information System (INIS)

    Keefe, D.J.

    1980-01-01

    An automatically sweeping circuit for searching for an evoked response in an output signal in time with respect to a trigger input is described. Digital counters are used to activate a detector at precise intervals, and monitoring is repeated for statistical accuracy. If the response is not found then a different time window is examined until the signal is found

  9. Automatic sweep circuit

    Science.gov (United States)

    Keefe, Donald J.

    1980-01-01

    An automatically sweeping circuit for searching for an evoked response in an output signal in time with respect to a trigger input. Digital counters are used to activate a detector at precise intervals, and monitoring is repeated for statistical accuracy. If the response is not found then a different time window is examined until the signal is found.

  10. "Printed-circuit" rectenna

    Science.gov (United States)

    Dickinson, R. M.

    1977-01-01

    Rectifying antenna is less bulky structure for absorbing transmitted microwave power and converting it into electrical current. Printed-circuit approach, using microstrip technology and circularly polarized antenna, makes polarization orientation unimportant and allows much smaller arrays for given performance. Innovation is particularly useful with proposed electric vehicles powered by beam microwaves.

  11. Het onzichtbare circuit

    NARCIS (Netherlands)

    Nauta, Bram

    2013-01-01

    De chip, of geïntegreerde schakeling, heeft in een razend tempo ons leven ingrijpend veranderd. Het lijkt zo vanzelfsprekend dat er weer een nieuwe generatie smartphones, tablets of computers is. Maar dat is het niet. Prof.dr.ir. Bram Nauta, hoogleraar Integrated Circuit Design, laat in zijn rede

  12. Voltage regulating circuit

    NARCIS (Netherlands)

    2005-01-01

    A voltage regulating circuit comprising a rectifier (2) for receiving an AC voltage (Vmains) and for generating a rectified AC voltage (vrec), and a capacitor (3) connected in parallel with said rectified AC voltage for providing a DC voltage (VDC) over a load (5), characterized by a unidirectional

  13. Streaming Reduction Circuit

    NARCIS (Netherlands)

    Gerards, Marco Egbertus Theodorus; Kuper, Jan; Kokkeler, Andre B.J.; Molenkamp, Egbert

    2009-01-01

    Reduction circuits are used to reduce rows of floating point values to single values. Binary floating point operators often have deep pipelines, which may cause hazards when many consecutive rows have to be reduced. We present an algorithm by which any number of consecutive rows of arbitrary lengths

  14. A Magnetic Circuit Demonstration.

    Science.gov (United States)

    Vanderkooy, John; Lowe, June

    1995-01-01

    Presents a demonstration designed to illustrate Faraday's, Ampere's, and Lenz's laws and to reinforce the concepts through the analysis of a two-loop magnetic circuit. Can be made dramatic and challenging for sophisticated students but is suitable for an introductory course in electricity and magnetism. (JRH)

  15. Adaptive quantization-parameter clip scheme for smooth quality in H.264/AVC.

    Science.gov (United States)

    Hu, Sudeng; Wang, Hanli; Kwong, Sam

    2012-04-01

    In this paper, we investigate the issues over the smooth quality and the smooth bit rate during rate control (RC) in H.264/AVC. An adaptive quantization-parameter (Q(p)) clip scheme is proposed to optimize the quality smoothness while keeping the bit-rate fluctuation at an acceptable level. First, the frame complexity variation is studied by defining a complexity ratio between two nearby frames. Second, the range of the generated bits is analyzed to prevent the encoder buffer from overflow and underflow. Third, based on the safe range of the generated bits, an optimal Q(p) clip range is developed to reduce the quality fluctuation. Experimental results demonstrate that the proposed Q(p) clip scheme can achieve excellent performance in quality smoothness and buffer regulation.

  16. New concept of 3D printed bone clip (polylactic acid/hydroxyapatite/silk composite) for internal fixation of bone fractures.

    Science.gov (United States)

    Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum

    Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.

  17. Impact of Aneurysm Projection on Intraoperative Complications During Surgical Clipping of Ruptured Posterior Communicating Artery Aneurysms.

    Science.gov (United States)

    Fukuda, Hitoshi; Hayashi, Kosuke; Yoshino, Kumiko; Koyama, Takashi; Lo, Benjamin; Kurosaki, Yoshitaka; Yamagata, Sen

    2016-03-01

    Surgical clipping of ruptured posterior communicating artery (PCoA) aneurysms is a well-established procedure to date. However, preoperative factors associated with procedure-related risk require further elucidation. To investigate the impact of the direction of aneurysm projection on the incidence of procedure-related complications during surgical clipping of ruptured PCoA aneurysms. A total of 65 patients with ruptured PCoA aneurysms who underwent surgical clipping were retrospectively analyzed from a single-center, prospective, observational cohort database in this study. The aneurysms were categorized into lateral and posterior projection groups, depending on direction of the dome. Characteristics and operative findings of each projection group were identified. We also evaluated any correlation of aneurysm projection with the incidence of procedure-related complications. Patients with ruptured PCoA aneurysms with posterior projection more likely presented with good-admission-grade subarachnoid hemorrhage (P = .01, χ test) and were less to also have intracerebral hematoma (P = .01). These aneurysms were found to be associated with higher incidence of intraoperative rupture (P = .02), complex clipping with fenestrated clips (P = .02), and dense adherence to PCoA or its perforators (P = .04) by univariate analysis. Aneurysms with posterior projection were also correlated with procedure-related complications, including postoperative cerebral infarction or hematoma formation (odds ratio, 5.87; 95% confidence interval, 1.11-31.1; P = .04) by multivariable analysis. Ruptured PCoA aneurysms with posterior projection carried a higher risk of procedure-related complications of surgical clipping than those with lateral projection.

  18. Fundamental Frequency Extraction Method using Central Clipping and its Importance for the Classification of Emotional State

    Directory of Open Access Journals (Sweden)

    Pavol Partila

    2012-01-01

    Full Text Available The paper deals with a classification of emotional state. We implemented a method for extracting the fundamental speech signal frequency by means of a central clipping and examined a correlation between emotional state and fundamental speech frequency. For this purpose, we applied an approach of exploratory data analysis. The ANOVA (Analysis of variance test confirmed that a modification in the speaker's emotional state changes the fundamental frequency of human vocal tract. The main contribution of the paper lies in investigation, of central clipping method by the ANOVA.

  19. Future of clip-on weapon sights: pros and cons from an applications perspective

    Science.gov (United States)

    Knight, C. Reed; Greenslade, Ken; Francisco, Glen

    2015-05-01

    US Domestic, International, allied Foreign National Warfighters and Para-Military First Responders (Police, SWAT, Special Operations, Law Enforcement, Government, Security and more) are put in harm's way all the time. To successfully complete their missions and return home safely are the primary goals of these professionals. Tactical product improvements that affect mission effectiveness and solider survivability are pivotal to understanding the past, present and future of Clip-On in-line weapon sights. Clip-On Weapon Sight (WS) technology was deemed an interim solution by the US Government for use until integrated and fused (day/night multi-sensor) Weapon Sights (WSs) were developed/fielded. Clip-On has now become the solution of choice by Users, Warriors, Soldiers and the US Government. SWaP-C (size, weight and power -cost) has been improved through progressive advances in Clip-On Image Intensified (I2), passive thermal, LL-CMOS and fused technology. Clip-On Weapon Sights are now no longer mounting position sensitive. Now they maintain aim point boresight, so they can be used for longer ranges with increased capabilities while utilizing the existing zeroed weapon and daysight optic. Active illuminated low-light level (both analog I2 and digital LL-CMOS) imaging is rightfully a real-world technology, proven to deliver daytime and low-light level identification confidence. Passive thermal imaging is also a real-world technology, proven to deliver daytime, nighttime and all-weather (including dirty battlefield) target detection confidence. Image processing detection algorithms with intelligent analytics provide documented promise to improve confidence by reducing Users, Warriors and Soldiers' work-loads and improving overall system engagement solution outcomes. In order to understand the future of Clip-On in-line weapon sights, addressing pros and cons, this paper starts with an overview of historical weapon sight applications, technologies and stakeholder decisions

  20. The use of shape memory compression anastomosis clips in cholecystojejunostomy in pigs – a preliminary study

    Directory of Open Access Journals (Sweden)

    Piotr Holak

    2015-01-01

    Full Text Available This paper reports on the use of compression anastomosis clips (CAC in cholecystoenterostomy in an animal model. Cholecystojejunostomy was performed in 6 pigs using implants made of nickel-titanium alloy in the form of elliptical springs with two-way shape memory. The applied procedure led to the achievement of tight anastomosis with a minimal number of complications and positive results of histopathological evaluations of the anastomotic site. The results of the study indicate that shape memory NiTi clips are a promising surgical tool for cholecystoenterostomy in cats and dogs.

  1. Emotion Index of Cover Song Music Video Clips based on Facial Expression Recognition

    DEFF Research Database (Denmark)

    Kavallakis, George; Vidakis, Nikolaos; Triantafyllidis, Georgios

    2017-01-01

    This paper presents a scheme of creating an emotion index of cover song music video clips by recognizing and classifying facial expressions of the artist in the video. More specifically, it fuses effective and robust algorithms which are employed for expression recognition, along with the use...... of a neural network system using the features extracted by the SIFT algorithm. Also we support the need of this fusion of different expression recognition algorithms, because of the way that emotions are linked to facial expressions in music video clips....

  2. Bayesian Recovery of Clipped OFDM Signals: A Receiver-based Approach

    KAUST Repository

    Al-Rabah, Abdullatif R.

    2013-05-01

    Recently, orthogonal frequency-division multiplexing (OFDM) has been adopted for high-speed wireless communications due to its robustness against multipath fading. However, one of the main fundamental drawbacks of OFDM systems is the high peak-to-average-power ratio (PAPR). Several techniques have been proposed for PAPR reduction. Most of these techniques require transmitter-based (pre-compensated) processing. On the other hand, receiver-based alternatives would save the power and reduce the transmitter complexity. By keeping this in mind, a possible approach is to limit the amplitude of the OFDM signal to a predetermined threshold and equivalently a sparse clipping signal is added. Then, estimating this clipping signal at the receiver to recover the original signal. In this work, we propose a Bayesian receiver-based low-complexity clipping signal recovery method for PAPR reduction. The method is able to i) effectively reduce the PAPR via simple clipping scheme at the transmitter side, ii) use Bayesian recovery algorithm to reconstruct the clipping signal at the receiver side by measuring part of subcarriers, iii) perform well in the absence of statistical information about the signal (e.g. clipping level) and the noise (e.g. noise variance), and at the same time iv is energy efficient due to its low complexity. Specifically, the proposed recovery technique is implemented in data-aided based. The data-aided method collects clipping information by measuring reliable 
data subcarriers, thus makes full use of spectrum for data transmission without the need for tone reservation. The study is extended further to discuss how to improve the recovery of the clipping signal utilizing some features of practical OFDM systems i.e., the oversampling and the presence of multiple receivers. Simulation results demonstrate the superiority of the proposed technique over other recovery algorithms. The overall objective is to show that the receiver-based Bayesian technique is highly

  3. Clinical outcome of critically ill, not fully recompensated, patients undergoing MitraClip therapy

    DEFF Research Database (Denmark)

    Rudolph, Volker; Huntgeburth, Michael; von Bardeleben, Ralph Stephan

    2014-01-01

    AIMS: As periprocedural risk is low, MitraClip implantation is often performed in critically ill, not fully recompensated patients, who are in NYHA functional class IV at the time of the procedure, to accelerate convalescence. We herein sought to evaluate the procedural and 30-day outcome.......3%. CONCLUSION: MitraClip therapy is feasible and safe even in critically ill, not fully recompensated patients and leads to symptomatic improvement in over two-thirds of these patients; however, it is associated with an elevated 30-day mortality....

  4. The LMT circuit and SPICE

    DEFF Research Database (Denmark)

    Lindberg, Erik; Murali, K.; Tamacevicius, Arunas

    2006-01-01

    The state equations of the LMT circuit are modeled as a dedicated analogue computer circuit and solved by means of PSpice. The nonlinear part of the system is studied. Problems with the PSpice program are presented....

  5. Resistor Combinations for Parallel Circuits.

    Science.gov (United States)

    McTernan, James P.

    1978-01-01

    To help simplify both teaching and learning of parallel circuits, a high school electricity/electronics teacher presents and illustrates the use of tables of values for parallel resistive circuits in which total resistances are whole numbers. (MF)

  6. Detecting short circuits during assembly

    Science.gov (United States)

    Deboo, G. J.

    1980-01-01

    Detector circuit identifies shorts between bus bars of electronic equipment being wired. Detector sounds alarm and indicates which planes are shorted. Power and ground bus bars are scanned continuously until short circuit occurs.

  7. BR-5 primary circuit decontamination

    International Nuclear Information System (INIS)

    Efimov, I.A.; Nikulin, M.P.; Smirnov-Averin, A.P.; Tymosh, B.S.; Shereshkov, V.S.

    1976-01-01

    Results and methodology of steam-water and acid decontamination of the primary coolant circuit SBR-5 reactor in 1971 are discussed. Regeneration process in a cold trap of the primary coolant circuit is discussed

  8. From benchmarking HITS-CLIP peak detection programs to a new method for identification of miRNA-binding sites from Ago2-CLIP data.

    Science.gov (United States)

    Bottini, Silvia; Hamouda-Tekaya, Nedra; Tanasa, Bogdan; Zaragosi, Laure-Emmanuelle; Grandjean, Valerie; Repetto, Emanuela; Trabucchi, Michele

    2017-05-19

    Experimental evidence indicates that about 60% of miRNA-binding activity does not follow the canonical rule about the seed matching between miRNA and target mRNAs, but rather a non-canonical miRNA targeting activity outside the seed or with a seed-like motifs. Here, we propose a new unbiased method to identify canonical and non-canonical miRNA-binding sites from peaks identified by Ago2 Cross-Linked ImmunoPrecipitation associated to high-throughput sequencing (CLIP-seq). Since the quality of peaks is of pivotal importance for the final output of the proposed method, we provide a comprehensive benchmarking of four peak detection programs, namely CIMS, PIPE-CLIP, Piranha and Pyicoclip, on four publicly available Ago2-HITS-CLIP datasets and one unpublished in-house Ago2-dataset in stem cells. We measured the sensitivity, the specificity and the position accuracy toward miRNA binding sites identification, and the agreement with TargetScan. Secondly, we developed a new pipeline, called miRBShunter, to identify canonical and non-canonical miRNA-binding sites based on de novo motif identification from Ago2 peaks and prediction of miRNA::RNA heteroduplexes. miRBShunter was tested and experimentally validated on the in-house Ago2-dataset and on an Ago2-PAR-CLIP dataset in human stem cells. Overall, we provide guidelines to choose a suitable peak detection program and a new method for miRNA-target identification. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  9. MOS voltage automatic tuning circuit

    OpenAIRE

    李, 田茂; 中田, 辰則; 松本, 寛樹

    2004-01-01

    Abstract ###Automatic tuning circuit adjusts frequency performance to compensate for the process variation. Phase locked ###loop (PLL) is a suitable oscillator for the integrated circuit. It is a feedback system that compares the input ###phase with the output phase. It can make the output frequency equal to the input frequency. In this paper, PLL ###fomed of MOSFET's is presented.The presented circuit consists of XOR circuit, Low-pass filter and Relaxation ###Oscillator. On PSPICE simulation...

  10. Behavioral synthesis of asynchronous circuits

    DEFF Research Database (Denmark)

    Nielsen, Sune Fallgaard

    2005-01-01

    This thesis presents a method for behavioral synthesis of asynchronous circuits, which aims at providing a synthesis flow which uses and tranfers methods from synchronous circuits to asynchronous circuits. We move the synchronous behavioral synthesis abstraction into the asynchronous handshake...... is idle. This reduces unnecessary switching activity in the individual functional units and therefore the energy consumption of the entire circuit. A collection of behavioral synthesis algorithms have been developed allowing the designer to perform time and power constrained design space exploration...

  11. Selected collection of circuit drawings

    International Nuclear Information System (INIS)

    1977-01-01

    The many electronics circuits have been constracted in the Electronics Shop for use in nuclear experiments or other purposes of this Institute. The types of these circuits amount to about 500 items in total since 1968. This report describes the electronics circuit diagrams selected from this collection. The circuit details are not presented in this report, because these are already been published in the other technical reports. (auth.)

  12. Diode, transistor & fet circuits manual

    CERN Document Server

    Marston, R M

    2013-01-01

    Diode, Transistor and FET Circuits Manual is a handbook of circuits based on discrete semiconductor components such as diodes, transistors, and FETS. The book also includes diagrams and practical circuits. The book describes basic and special diode characteristics, heat wave-rectifier circuits, transformers, filter capacitors, and rectifier ratings. The text also presents practical applications of associated devices, for example, zeners, varicaps, photodiodes, or LEDs, as well as it describes bipolar transistor characteristics. The transistor can be used in three basic amplifier configuration

  13. Analysis of Bernstein's factorization circuit

    NARCIS (Netherlands)

    Lenstra, A.K.; Shamir, A.; Tomlinson, J.; Tromer, E.; Zheng, Y.

    2002-01-01

    In [1], Bernstein proposed a circuit-based implementation of the matrix step of the number field sieve factorization algorithm. These circuits offer an asymptotic cost reduction under the measure "construction cost x run time". We evaluate the cost of these circuits, in agreement with [1], but argue

  14. High voltage MOSFET switching circuit

    Science.gov (United States)

    McEwan, Thomas E.

    1994-01-01

    The problem of source lead inductance in a MOSFET switching circuit is compensated for by adding an inductor to the gate circuit. The gate circuit inductor produces an inductive spike which counters the source lead inductive drop to produce a rectangular drive voltage waveform at the internal gate-source terminals of the MOSFET.

  15. 78 FR 78319 - Media Bureau Seeks Comment on Application of the IP Closed Captioning Rules to Video Clips

    Science.gov (United States)

    2013-12-26

    ... Video Programming: Implementation of the Twenty-First Century Communications and Video Accessibility Act..., pursuant to the Twenty-First Century Communications and Video Accessibility Act of 2010 (``CVAA''),\\2\\ the... clips, especially news clips.\\8\\ The Commission stated that if it finds that consumers who are deaf or...

  16. Effect of advanced chronic kidney disease in clinical and echocardiographic outcomes of patients treated with MitraClip system

    DEFF Research Database (Denmark)

    Estévez-Loureiro, Rodrigo; Settergren, Magnus; Pighi, Michele

    2015-01-01

    BACKGROUND: Data regarding the influence of different levels of renal dysfunction on clinical and echocardiographic results of MitraClip therapy are scarce. We aimed to evaluate the impact of baseline advance renal failure in the outcomes of a cohort of patients treated with MitraClip. METHODS AN...

  17. Comparison of Outcome After Percutaneous Mitral Valve Repair With the MitraClip in Patients With Versus Without Atrial Fibrillation

    NARCIS (Netherlands)

    Velu, Juliëtte F.; Kortlandt, Friso A.; Hendriks, Tom; Schurer, Remco A. J.; van Boven, Ad J.; Koch, Karel T.; Vis, M. Marije; Henriques, Jose P.; Piek, Jan J.; van den Branden, Ben J. L.; Schaap, Jeroen; Rensing, Benno J.; Swaans, Martin J.; Bouma, Berto J.; van der Heyden, Jan A. S.; Baan, Jan

    2017-01-01

    Percutaneous mitral valve repair with the MitraClip is an established treatment for patients with mitral regurgitation (MR) who are inoperable or at high risk for surgery. Atrial Fibrillation (AF) frequently coincides with MR, but only scarce data of the influence of AF on outcome after MitraClip is

  18. Current opinion on clip placement after breast biopsy: A survey of practising radiologists in France and Quebec

    International Nuclear Information System (INIS)

    Thomassin-Naggara, I.; Jalaguier-Coudray, A.; Chopier, J.; Tardivon, A.; Trop, I.

    2013-01-01

    Aim: To investigate current practice regarding clip placement after breast biopsy. Materials and methods: In June 2011, an online survey instrument was designed using an Internet-based survey site ( (www.surveymonkey.com)) to assess practices and opinions of breast radiologists regarding clip placement after breast biopsy. Radiologists were asked to give personal practice data, describe their current practice regarding clip deployment under stereotactic, ultrasonographic, and magnetic resonance imaging (MRI) guidance, and describe what steps are taken to ensure quality control with regards to clip deployment. Results: The response rate was 29.9% in France (131 respondents) and 46.7% in Quebec (50 respondents). The great majority of respondents used breast markers in their practice (92.1% in France and 96% in Quebec). In both countries, most reported deploying a clip after percutaneous biopsy under stereotactic or MRI guidance. Regarding clip deployment under ultrasonography, 38% of Quebec radiologists systematically placed a marker after each biopsy, whereas 30% of French radiologists never placed a marker in this situation, mainly due to its cost. Finally, 56.4% of radiologists in France and 54% in Quebec considered that their practice regarding clip deployment after breast percutaneous biopsy had changed in the last 5 years. Conclusion: There continues to be variations in the use of biopsy clips after imaging-guided biopsies, particularly with regards to sonographic techniques. These variations are likely to decrease over time, with the standardization of relatively new investigation protocols

  19. Neuromorphic Silicon Neuron Circuits

    Science.gov (United States)

    Indiveri, Giacomo; Linares-Barranco, Bernabé; Hamilton, Tara Julia; van Schaik, André; Etienne-Cummings, Ralph; Delbruck, Tobi; Liu, Shih-Chii; Dudek, Piotr; Häfliger, Philipp; Renaud, Sylvie; Schemmel, Johannes; Cauwenberghs, Gert; Arthur, John; Hynna, Kai; Folowosele, Fopefolu; Saighi, Sylvain; Serrano-Gotarredona, Teresa; Wijekoon, Jayawan; Wang, Yingxue; Boahen, Kwabena

    2011-01-01

    Hardware implementations of spiking neurons can be extremely useful for a large variety of applications, ranging from high-speed modeling of large-scale neural systems to real-time behaving systems, to bidirectional brain–machine interfaces. The specific circuit solutions used to implement silicon neurons depend on the application requirements. In this paper we describe the most common building blocks and techniques used to implement these circuits, and present an overview of a wide range of neuromorphic silicon neurons, which implement different computational models, ranging from biophysically realistic and conductance-based Hodgkin–Huxley models to bi-dimensional generalized adaptive integrate and fire models. We compare the different design methodologies used for each silicon neuron design described, and demonstrate their features with experimental results, measured from a wide range of fabricated VLSI chips. PMID:21747754

  20. Neuromorphic silicon neuron circuits

    Directory of Open Access Journals (Sweden)

    Giacomo eIndiveri

    2011-05-01

    Full Text Available Hardware implementations of spiking neurons can be extremely useful for a large variety of applications, ranging from high-speed modeling of large-scale neural systems to real-time behaving systems, to bidirectional brain-machine interfaces. The specific circuit solutions used to implement silicon neurons depend on the application requirements. In this paper we describe the most common building blocks and techniques used to implement these circuits, and present an overview of a wide range of neuromorphic silicon neurons, which implement different computational models, ranging from biophysically realistic and conductance based Hodgkin-Huxley models to bi-dimensional generalized adaptive Integrate and Fire models. We compare the different design methodologies used for each silicon neuron design described, and demonstrate their features with experimental results, measured from a wide range of fabricated VLSI chips.

  1. Integrated circuit structure

    International Nuclear Information System (INIS)

    1981-01-01

    The invention describes the fabrication of integrated circuit structures, such as read-only memory components of field-effect transistors, which may be fabricated and then maintained in inventory, and later selectively modified in accordance with a desired pattern. It is claimed that MOS depletion-mode devices in accordance with the invention can be fabricated at lower cost and at higher yields. (U.K.)

  2. Integrated Circuit Immunity

    Science.gov (United States)

    Sketoe, J. G.; Clark, Anthony

    2000-01-01

    This paper presents a DOD E3 program overview on integrated circuit immunity. The topics include: 1) EMI Immunity Testing; 2) Threshold Definition; 3) Bias Tee Function; 4) Bias Tee Calibration Set-Up; 5) EDM Test Figure; 6) EMI Immunity Levels; 7) NAND vs. and Gate Immunity; 8) TTL vs. LS Immunity Levels; 9) TP vs. OC Immunity Levels; 10) 7805 Volt Reg Immunity; and 11) Seventies Chip Set. This paper is presented in viewgraph form.

  3. Integrated coincidence circuits

    International Nuclear Information System (INIS)

    Borejko, V.F.; Grebenyuk, V.M.; Zinov, V.G.

    1976-01-01

    The description is given of two coincidence units employing integral circuits in the VISHNYA standard. The units are distinguished for the coincidence selection element which is essentially a combination of a tunnel diode and microcircuits. The output fast response of the units is at least 90 MHz in the mode of the output signal unshaped in duration and 50 MHz minimum in the mode of the output signal shaping. The resolution time of the units is dependent upon the duration of input signals

  4. Semiconductor integrated circuits

    International Nuclear Information System (INIS)

    Michel, A.E.; Schwenker, R.O.; Ziegler, J.F.

    1979-01-01

    An improved method involving ion implantation to form non-epitaxial semiconductor integrated circuits. These are made by forming a silicon substrate of one conductivity type with a recessed silicon dioxide region extending into the substrate and enclosing a portion of the silicon substrate. A beam of ions of opposite conductivity type impurity is directed at the substrate at an energy and dosage level sufficient to form a first region of opposite conductivity within the silicon dioxide region. This impurity having a concentration peak below the surface of the substrate forms a region of the one conductivity type which extends from the substrate surface into the first opposite type region to a depth between the concentration peak and the surface and forms a second region of opposite conductivity type. The method, materials and ion beam conditions are detailed. Vertical bipolar integrated circuits can be made this way when the first opposite type conductivity region will function as a collector. Also circuits with inverted bipolar devices when this first region functions as a 'buried'' emitter region. (U.K.)

  5. Interface Circuit For Printer Port

    Science.gov (United States)

    Tucker, Jerry H.; Yadlowsky, Ann B.

    1991-01-01

    Electronic circuit, called printer-port interface circuit (PPI) developed to overcome certain disadvantages of previous methods for connecting IBM PC or PC-compatible computer to other equipment. Has both reading and writing modes of operation. Very simple, requiring only six integrated circuits. Provides for moderately fast rates of transfer of data and uses existing unmodified circuit card in IBM PC. When used with appropriate software, circuit converts printer port on IBM PC, XT, AT, or compatible personal computer to general purpose, 8-bit-data, 16-bit address bus that connects to multitude of devices.

  6. Changes to the shuttle circuits

    CERN Multimedia

    GS Department

    2011-01-01

    To fit with passengers expectation, there will be some changes to the shuttle circuits as from Monday 10 October. See details on http://cern.ch/ShuttleService (on line on 7 October). Circuit No. 5 is cancelled as circuit No. 1 also stops at Bldg. 33. In order to guarantee shorter travel times, circuit No. 1 will circulate on Meyrin site only and circuit No. 2, with departures from Bldg. 33 and 500, on Prévessin site only. Site Services Section

  7. Thermionic integrated circuits: electronics for hostile environments

    International Nuclear Information System (INIS)

    Lynn, D.K.; McCormick, J.B.; MacRoberts, M.D.J.; Wilde, D.K.; Dooley, G.R.; Brown, D.R.

    1985-01-01

    Thermionic integrated circuits combine vacuum tube technology with integrated circuit techniques to form integrated vacuum triode circuits. These circuits are capable of extended operation in both high-temperature and high-radiation environments

  8. Power system with an integrated lubrication circuit

    Science.gov (United States)

    Hoff, Brian D [East Peoria, IL; Akasam, Sivaprasad [Peoria, IL; Algrain, Marcelo C [Peoria, IL; Johnson, Kris W [Washington, IL; Lane, William H [Chillicothe, IL

    2009-11-10

    A power system includes an engine having a first lubrication circuit and at least one auxiliary power unit having a second lubrication circuit. The first lubrication circuit is in fluid communication with the second lubrication circuit.

  9. MRI-validation of SEP monitoring for ischemic events during microsurgical clipping of intracranial aneurysms.

    Science.gov (United States)

    Krayenbühl, Niklaus; Sarnthein, Johannes; Oinas, Minna; Erdem, Eren; Krisht, Ali F

    2011-09-01

    During surgical clipping of intracranial aneurysms, reduction in SEP amplitude is thought to indicate cortical ischemia and subsequent neurological deficits. Since the sensitivity of SEP is questioned, we investigated SEP with respect to post-operative ischemia. In 36 patients with 51 intracranial aneurysms, clinical evaluation and diffusion-weighted MRI (DWI) was performed before and within 24h after surgery. During surgery, time of temporary occlusion was recorded. MRI images were reviewed for signs of ischemia. For 43 clip applications (84%), we observed neither pathologic SEP events nor ischemia in MRI. In two cases where reduction lasted >10 min after clip release, SEP events correlated with ischemia in the MRI. Only one of the ischemic patients was symptomatic and developed a transient hemiparesis. While pathologic SEP events correlated with visible ischemia in MRI only in two cases with late SEP recovery, ischemia in MRI may have been transient or may not have reached detection threshold in the other cases, in agreement with the absence of permanent neurological deficits. In complex aneurysm cases, where prolonged temporary occlusion is expected, SEP should be used to detect ischemia at a reversible stage to improve the safety of aneurysm clipping. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  10. Exploring the Use of Video-Clips for Motivation Building in a Secondary School EFL Setting

    Science.gov (United States)

    Park, Yujong; Jung, Eunsu

    2016-01-01

    By employing an action research framework, this study evaluated the effectiveness of a video-based curriculum in motivating EFL learners to learn English. Fifteen Korean EFL students at the secondary school context participated in an 8-week English program, which employed video clips including TED talk replays, sitcoms, TV news reports and movies…

  11. Endoscopic Management of Gastrocutaneous Fistula Using Clipping, Suturing, and Plugging Methods

    Directory of Open Access Journals (Sweden)

    Shou-jiang Tang

    2014-09-01

    Conclusions: Health care providers need to be aware of this uncommon complication after PEG tube removal and management it with appropriate minimally invasive options where expertise and devices are available. Currently, tissue approximation with clips, intra-gastric and/or trans-abdominal suture placement is the preferred endoscopic options for fistula closure.

  12. Hemodynamic control of in patients with concomitant hypertensive disease during brain aneurysm clipping

    OpenAIRE

    Dzyuba, D.O.; Melnik, A.F.; Yavorsky, F.A.

    2018-01-01

    The article describes the state of the problem of hemodynamic control during brain aneurysm clipping in concomitant hypertensive disease. Author studies hemodynamic control by using magnesia therapy with the addition of clonidine solution and infusion of urapidil solution. Based on the results of the study, the advantages of urapidil infusion are given.

  13. Cerebral Aneurysm Clipping Surgery Simulation Using Patient-Specific 3D Printing and Silicone Casting.

    Science.gov (United States)

    Ryan, Justin R; Almefty, Kaith K; Nakaji, Peter; Frakes, David H

    2016-04-01

    Neurosurgery simulator development is growing as practitioners recognize the need for improved instructional and rehearsal platforms to improve procedural skills and patient care. In addition, changes in practice patterns have decreased the volume of specific cases, such as aneurysm clippings, which reduces the opportunity for operating room experience. The authors developed a hands-on, dimensionally accurate model for aneurysm clipping using patient-derived anatomic data and three-dimensional (3D) printing. Design of the model focused on reproducibility as well as adaptability to new patient geometry. A modular, reproducible, and patient-derived medical simulacrum was developed for medical learners to practice aneurysmal clipping procedures. Various forms of 3D printing were used to develop a geometrically accurate cranium and vascular tree featuring 9 patient-derived aneurysms. 3D printing in conjunction with elastomeric casting was leveraged to achieve a patient-derived brain model with tactile properties not yet available from commercial 3D printing technology. An educational pilot study was performed to gauge simulation efficacy. Through the novel manufacturing process, a patient-derived simulacrum was developed for neurovascular surgical simulation. A follow-up qualitative study suggests potential to enhance current educational programs; assessments support the efficacy of the simulacrum. The proposed aneurysm clipping simulator has the potential to improve learning experiences in surgical environment. 3D printing and elastomeric casting can produce patient-derived models for a dynamic learning environment that add value to surgical training and preparation. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Response of Advance Cherrybark Oak Reproduction to Midstory Removal and Shoot Clipping

    Science.gov (United States)

    Brian R. Lockhart; John D. Hodges; Emile S. Gardiner

    2000-01-01

    A Midstory competition control and shoot clipping have been proposed to increase the vigor and height of advance bottomland oak reproduction. Results from a study in east-central Mississippi showed that advance cherrybark oak (Quercus pagoda Raf) released from midstory competition had greater survival than nonreleased seedlings, 64% and 48%,...

  15. Coiling and clipping of middle cerebral artery aneurysms: a systematic review on clinical and imaging outcome

    NARCIS (Netherlands)

    Zijlstra, Ijsbrand A.; Verbaan, Dagmar; Majoie, Charles B.; Vandertop, Peter; van den Berg, Rene

    2016-01-01

    There is an ongoing debate on the preferred treatment of middle cerebral artery (MCA) aneurysms. The purpose of this study was to assess the clinical and imaging outcomes comparing conventional coiling and clipping of unruptured and ruptured MCA aneurysms. We searched the electronic databases

  16. Tailfin clipping, a painful procedure: Studies on Nile tilapia and common carp

    NARCIS (Netherlands)

    Roques, J.A.C.; Abbink, W.; Geurds, F.; Vis, van de J.W.; Flik, G.

    2010-01-01

    The fish welfare debate is intensifying. Consequently, more research is carried out to further our knowledge on fish welfare in aquaculture. We define here a series of key parameters to substantiate an acute response to a supposedly painful stimulus: a standardized tailfin clip. Ultrastructural

  17. Drosophila Imp iCLIP identifies an RNA assemblage coordinating F-actin formation

    DEFF Research Database (Denmark)

    Hansen, Heidi Theil; Rasmussen, Simon Horskjær; Adolph, Sidsel Kramshøj

    2015-01-01

    BACKGROUND: Post-transcriptional RNA regulons ensure co-ordinated expression of monocistronic mRNAs encoding functionally related proteins. In this study, we employ a combination of RIP-seq and short- and long-wave individual-nucleotide resolution crosslinking and immunoprecipitation (iCLIP...

  18. Anterior communicating artery aneurysm clipping versus coiling: a comparative study of 50 cases

    Directory of Open Access Journals (Sweden)

    Kumar Pradeep

    2017-09-01

    Full Text Available Introduction: Aneurysmal Subarachnoid Hemorrhage (aSAH remains a devastating and often fatal form of stroke. The aneurysm is targeted for obliteration to prevent re-bleeding and to manage the possible complications from the event. Endovascular coiling has emerged as a less invasive alternative to conventional surgical clipping to treat aneurysms.

  19. Real-time video streaming of sonographic clips using domestic internet networks and free videoconferencing software.

    Science.gov (United States)

    Liteplo, Andrew S; Noble, Vicki E; Attwood, Ben H C

    2011-11-01

    As the use of point-of-care sonography spreads, so too does the need for remote expert over-reading via telesonogrpahy. We sought to assess the feasibility of using familiar, widespread, and cost-effective existent technology to allow remote over-reading of sonograms in real time and to compare 4 different methods of transmission and communication for both the feasibility of transmission and image quality. Sonographic video clips were transmitted using 2 different connections (WiFi and 3G) and via 2 different videoconferencing modalities (iChat [Apple Inc, Cupertino, CA] and Skype [Skype Software Sàrl, Luxembourg]), for a total of 4 different permutations. The clips were received at a remote location and recorded and then scored by expert reviewers for image quality, resolution, and detail. Wireless transmission of sonographic clips was feasible in all cases when WiFi was used and when Skype was used over a 3G connection. Images transmitted via a WiFi connection were statistically superior to those transmitted via 3G in all parameters of quality (average P = .031), and those sent by iChat were superior to those sent by Skype but not statistically so (average P = .057). Wireless transmission of sonographic video clips using inexpensive hardware, free videoconferencing software, and domestic Internet networks is feasible with retention of image quality sufficient for interpretation. WiFi transmission results in greater image quality than transmission by a 3G network.

  20. Custom-made different designs of pressure clips for the management of ear lobe keloids

    Directory of Open Access Journals (Sweden)

    Anshul Chugh

    2013-01-01

    Full Text Available Introduction : Keloids are frequent finding after physical trauma. Keloids of ear lobe are common complication of ear piercing, although its incidence remains unknown. The use of intrakeloid resection and a form pressure device to treat pinna keloids. The recommendation of this therapy is to maintain constant pressure and duration of pressure therapy was about 25 weeks. Clinical innovation : This article will present inexpensive custom made pressure clips of various designs. The dimensions of polymethylmethacrylate (PMMA plates in ear lobe clip presented by us though they esthetically not so good, but colored PMMA has been used to make it decorative and acceptable by most of the patients. This has been an encouraging experience to use the different designs. Discussion : Ear clip prosthesis has been developed for maintaining pressure on ear lobe keloids before and after surgical removal. The prosthesis includes an ear clip to which heat-polymerized acrylic resin is attached, which covers the keloid area. Pressure therapy is widely used to help in the early maturation of scar tissue and to prevent the recurrence of keloid. The preliminary report by Brent revealed that constant light pressure was an effective means of preventing post excision recurrence of ear lobe keloids using a decorative, spring-pressure earring.

  1. Portable inference engine: An extended CLIPS for real-time production systems

    Science.gov (United States)

    Le, Thach; Homeier, Peter

    1988-01-01

    The present C-Language Integrated Production System (CLIPS) architecture has not been optimized to deal with the constraints of real-time production systems. Matching in CLIPS is based on the Rete Net algorithm, whose assumption of working memory stability might fail to be satisfied in a system subject to real-time dataflow. Further, the CLIPS forward-chaining control mechanism with a predefined conflict resultion strategy may not effectively focus the system's attention on situation-dependent current priorties, or appropriately address different kinds of knowledge which might appear in a given application. Portable Inference Engine (PIE) is a production system architecture based on CLIPS which attempts to create a more general tool while addressing the problems of real-time expert systems. Features of the PIE design include a modular knowledge base, a modified Rete Net algorithm, a bi-directional control strategy, and multiple user-defined conflict resolution strategies. Problems associated with real-time applications are analyzed and an explanation is given for how the PIE architecture addresses these problems.

  2. Physiological remodeling of bifurcation aneurysms: preclinical results of the eCLIPs device.

    Science.gov (United States)

    Marotta, Thomas R; Riina, Howard A; McDougall, Ian; Ricci, Donald R; Killer-Oberpfalzer, Monika

    2018-02-01

    OBJECTIVE Intracranial bifurcation aneurysms are complex lesions for which current therapy, including simple coiling, balloon- or stent-assisted coiling, coil retention, or intrasaccular devices, is inadequate. Thromboembolic complications due to a large burden of intraluminal metal, impedance of access to side branches, and a high recurrence rate, due largely to the unmitigated high-pressure flow into the aneurysm (water hammer effect), are among the limitations imposed by current therapy. The authors describe herein a novel device, eCLIPs, and its use in a preclinical laboratory study that suggests the device's design and functional features may overcome many of these limitations. METHODS A preclinical model of wide-necked bifurcation aneurysms in rabbits was used to assess functional features and efficacy of aneurysm occlusion by the eCLIPs device. RESULTS The eCLIPs device, in bridging the aneurysm neck, allows coil retention, disrupts flow away from the aneurysm, leaves the main vessel and side branches unencumbered by intraluminal metal, and serves as a platform for endothelial growth across the neck, excluding the aneurysm from the circulation. CONCLUSIONS The eCLIPs device permits physiological remodeling of the bifurcation.

  3. Virtual reality cerebral aneurysm clipping simulation with real-time haptic feedback.

    Science.gov (United States)

    Alaraj, Ali; Luciano, Cristian J; Bailey, Daniel P; Elsenousi, Abdussalam; Roitberg, Ben Z; Bernardo, Antonio; Banerjee, P Pat; Charbel, Fady T

    2015-03-01

    With the decrease in the number of cerebral aneurysms treated surgically and the increase of complexity of those treated surgically, there is a need for simulation-based tools to teach future neurosurgeons the operative techniques of aneurysm clipping. To develop and evaluate the usefulness of a new haptic-based virtual reality simulator in the training of neurosurgical residents. A real-time sensory haptic feedback virtual reality aneurysm clipping simulator was developed using the ImmersiveTouch platform. A prototype middle cerebral artery aneurysm simulation was created from a computed tomographic angiogram. Aneurysm and vessel volume deformation and haptic feedback are provided in a 3-dimensional immersive virtual reality environment. Intraoperative aneurysm rupture was also simulated. Seventeen neurosurgery residents from 3 residency programs tested the simulator and provided feedback on its usefulness and resemblance to real aneurysm clipping surgery. Residents thought that the simulation would be useful in preparing for real-life surgery. About two-thirds of the residents thought that the 3-dimensional immersive anatomic details provided a close resemblance to real operative anatomy and accurate guidance for deciding surgical approaches. They thought the simulation was useful for preoperative surgical rehearsal and neurosurgical training. A third of the residents thought that the technology in its current form provided realistic haptic feedback for aneurysm surgery. Neurosurgical residents thought that the novel immersive VR simulator is helpful in their training, especially because they do not get a chance to perform aneurysm clippings until late in their residency programs.

  4. [Rapid 3-Dimensional Models of Cerebral Aneurysm for Emergency Surgical Clipping].

    Science.gov (United States)

    Konno, Takehiko; Mashiko, Toshihiro; Oguma, Hirofumi; Kaneko, Naoki; Otani, Keisuke; Watanabe, Eiju

    2016-08-01

    We developed a method for manufacturing solid models of cerebral aneurysms, with a shorter printing time than that involved in conventional methods, using a compact 3D printer with acrylonitrile-butadiene-styrene(ABS)resin. We further investigated the application and utility of this printing system in emergency clipping surgery. A total of 16 patients diagnosed with acute subarachnoid hemorrhage resulting from cerebral aneurysm rupture were enrolled in the present study. Emergency clipping was performed on the day of hospitalization. Digital Imaging and Communication in Medicine(DICOM)data obtained from computed tomography angiography(CTA)scans were edited and converted to stereolithography(STL)file formats, followed by the production of 3D models of the cerebral aneurysm by using the 3D printer. The mean time from hospitalization to the commencement of surgery was 242 min, whereas the mean time required for manufacturing the 3D model was 67 min. The average cost of each 3D model was 194 Japanese Yen. The time required for manufacturing the 3D models shortened to approximately 1 hour with increasing experience of producing 3D models. Favorable impressions for the use of the 3D models in clipping were reported by almost all neurosurgeons included in this study. Although 3D printing is often considered to involve huge costs and long manufacturing time, the method used in the present study requires shorter time and lower costs than conventional methods for manufacturing 3D cerebral aneurysm models, thus making it suitable for use in emergency clipping.

  5. Polymer Basics: Classroom Activities Manipulating Paper Clips to Introduce the Structures and Properties of Polymers

    Science.gov (United States)

    Umar, Yunusa

    2014-01-01

    A simple and effective hands-on classroom activity designed to illustrate basic polymer concepts is presented. In this activity, students build primary structures of homopolymers and different arrangements of monomers in copolymer using paper clips as monomers. The activity supports formation of a basic understanding of polymer structures,…

  6. A calibration method for proposed XRF measurements of arsenic and selenium in nail clippings

    International Nuclear Information System (INIS)

    Gherase, Mihai R; Fleming, David E B

    2011-01-01

    A calibration method for proposed x-ray fluorescence (XRF) measurements of arsenic and selenium in nail clippings is demonstrated. Phantom nail clippings were produced from a whole nail phantom (0.7 mm thickness, 25 x 25 mm 2 area) and contained equal concentrations of arsenic and selenium ranging from 0 to 20 μg g -1 in increments of 5 μg g -1 . The phantom nail clippings were then grouped in samples of five different masses: 20, 40, 60, 80 and 100 mg for each concentration. Experimental x-ray spectra were acquired for each of the sample masses using a portable x-ray tube and a detector unit. Calibration lines (XRF signal in a number of counts versus stoichiometric elemental concentration) were produced for each of the two elements. A semi-empirical relationship between the mass of the nail phantoms (m) and the slope of the calibration line (s) was determined separately for arsenic and selenium. Using this calibration method, one can estimate elemental concentrations and their uncertainties from the XRF spectra of human nail clippings. (note)

  7. Metallic clip migration to the common bile duct after laparoscopic surgery of the gallbladder

    International Nuclear Information System (INIS)

    Mendoza, Monica E.; Bauni, Carlos E.; Vives, Daniel A.

    2001-01-01

    We report a case of a 65 years old man with jaundice and cholangitis, appeared 8 month after laparoscopic cholecystectomy. CT demonstrated a surgical endo-clip migrated into the common bile duct. CT diagnosis was accurate. The patient had a good clinical evolution after successful endoscopic therapy. (author)

  8. Integrated coherent matter wave circuits

    International Nuclear Information System (INIS)

    Ryu, C.; Boshier, M. G.

    2015-01-01

    An integrated coherent matter wave circuit is a single device, analogous to an integrated optical circuit, in which coherent de Broglie waves are created and then launched into waveguides where they can be switched, divided, recombined, and detected as they propagate. Applications of such circuits include guided atom interferometers, atomtronic circuits, and precisely controlled delivery of atoms. We report experiments demonstrating integrated circuits for guided coherent matter waves. The circuit elements are created with the painted potential technique, a form of time-averaged optical dipole potential in which a rapidly moving, tightly focused laser beam exerts forces on atoms through their electric polarizability. Moreover, the source of coherent matter waves is a Bose-Einstein condensate (BEC). Finally, we launch BECs into painted waveguides that guide them around bends and form switches, phase coherent beamsplitters, and closed circuits. These are the basic elements that are needed to engineer arbitrarily complex matter wave circuitry

  9. Phosphorus runoff from turfgrass as affected by phosphorus fertilization and clipping management.

    Science.gov (United States)

    Bierman, Peter M; Horgan, Brian P; Rosen, Carl J; Hollman, Andrew B; Pagliari, Paulo H

    2010-01-01

    Phosphorus enrichment of surface water is a concern in many urban watersheds. A 3-yr study on a silt loam soil with 5% slope and high soil test P (27 mg kg(-1) Bray P1) was conducted to evaluate P fertilization and clipping management effects on P runoff from turfgrass (Poa pratensis L.) under frozen and nonfrozen conditions. Four fertilizer treatments were compared: (i) no fertilizer, (ii) nitrogen (N)+potassium (K)+0xP, (iii) N+K+1xP, and (iv) N+K+3xP. Phosphorus rates were 21.3 and 63.9 kg ha(-1) yr(-1) the first year and 7.1 and 21.3 kg ha(-1) yr(-1) the following 2 yr. Each fertilizer treatment was evaluated with clippings removed or clippings recycled back to the turf. In the first year, P runoff increased with increasing P rate and P losses were greater in runoff from frozen than nonfrozen soil. In year 2, total P runoff from the no fertilizer treatment was greater than from treatments receiving fertilizer. This was because reduced turf quality resulted in greater runoff depth from the no fertilizer treatment. In year 3, total P runoff from frozen soil and cumulative total P runoff increased with increasing P rate. Clipping management was not an important factor in any year, indicating that returning clippings does not significantly increase P runoff from turf. In the presence of N and K, P fertilization did not improve turf growth or quality in any year. Phosphorus runoff can be reduced by not applying P to high testing soils and avoiding fall applications when P is needed.

  10. Surgical Clipping versus Endovascular Intervention for the Treatment of Subarachnoid Hemorrhage Patients in New York State.

    Directory of Open Access Journals (Sweden)

    Kimon Bekelis

    Full Text Available Randomized trials have demonstrated a survival benefit for endovascular treatment of ruptured cerebral aneurysms. We investigated the association of surgical clipping and endovascular coiling with outcomes in subarachnoid hemorrhage (SAH patients in a real-world regional cohort.We performed a cohort study involving patients with ruptured cerebral aneurysms, who underwent surgical clipping, or endovascular coiling from 2009-2013 and were registered in the Statewide Planning and Research Cooperative System (SPARCS database. An instrumental variable analysis was used to investigate the association of treatment technique with outcomes.Of the 4,098 patients undergoing treatment, 2,585 (63.1% underwent coiling, and 1,513 (36.9% underwent clipping. Using an instrumental variable analysis, we did not identify a difference in inpatient mortality [marginal effect (ME, -0.56; 95% CI, -1.03 to 0.02], length of stay (LOS (ME, 1.72; 95% CI, -3.39 to 6.84, or the rate of 30-day readmissions (ME, -0.30; 95% CI, -0.82 to 0.22 between the two treatment techniques for patients with SAH. Clipping was associated with a higher rate of discharge to rehabilitation (ME, 0.63; 95% CI, 0.24 to 1.01. In sensitivity analysis, mixed effect regression, and propensity score adjusted regression models demonstrated identical results.Using a comprehensive all-payer cohort of patients in New York State presenting with aneurysmal SAH we did not identify an association of treatment method with mortality, LOS or 30-day readmission. Clipping was associated with a higher rate of discharge to rehabilitation.

  11. Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling.

    Science.gov (United States)

    Shen, Guangping; Zhang, Songning; Bennett, Hunter J; Martin, James C; Crouter, Scott E; Fitzhugh, Eugene C

    2018-06-01

    Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling.

  12. Dynamic pulse difference circuit

    International Nuclear Information System (INIS)

    Erickson, G.L.

    1978-01-01

    A digital electronic circuit of especial use for subtracting background activity pulses in gamma spectrometry is disclosed which comprises an up-down counter connected to count up with signal-channel pulses and to count down with background-channel pulses. A detector responsive to the count position of the up-down counter provides a signal when the up-down counter has completed one scaling sequence cycle of counts in the up direction. In an alternate embodiment, a detector responsive to the count position of the up-down counter provides a signal upon overflow of the counter

  13. Electronics circuits and systems

    CERN Document Server

    Bishop, Owen

    2007-01-01

    The material in Electronics - Circuits and Systems is a truly up-to-date textbook, with coverage carefully matched to the electronics units of the 2007 BTEC National Engineering and the latest AS and A Level specifications in Electronics from AQA, OCR and WJEC. The material has been organized with a logical learning progression, making it ideal for a wide range of pre-degree courses in electronics. The approach is student-centred and includes: numerous examples and activities; web research topics; Self Test features, highlighted key facts, formulae and definitions. Each chapter ends with a set

  14. Electric circuits problem solver

    CERN Document Server

    REA, Editors of

    2012-01-01

    Each Problem Solver is an insightful and essential study and solution guide chock-full of clear, concise problem-solving gems. All your questions can be found in one convenient source from one of the most trusted names in reference solution guides. More useful, more practical, and more informative, these study aids are the best review books and textbook companions available. Nothing remotely as comprehensive or as helpful exists in their subject anywhere. Perfect for undergraduate and graduate studies.Here in this highly useful reference is the finest overview of electric circuits currently av

  15. Digital logic circuit test

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Gil Jung; Yang, Hong Young

    2011-03-15

    This book is about digital logic circuit test, which lists the digital basic theory, basic gate like and, or And Not gate, NAND/NOR gate such as NAND gate, NOR gate, AND and OR, logic function, EX-OR gate, adder and subtractor, decoder and encoder, multiplexer, demultiplexer, flip-flop, counter such as up/down counter modulus N counter and Reset type counter, shift register, D/A and A/D converter and two supplements list of using components and TTL manual and CMOS manual.

  16. Photonic Integrated Circuits

    Science.gov (United States)

    Krainak, Michael; Merritt, Scott

    2016-01-01

    Integrated photonics generally is the integration of multiple lithographically defined photonic and electronic components and devices (e.g. lasers, detectors, waveguides passive structures, modulators, electronic control and optical interconnects) on a single platform with nanometer-scale feature sizes. The development of photonic integrated circuits permits size, weight, power and cost reductions for spacecraft microprocessors, optical communication, processor buses, advanced data processing, and integrated optic science instrument optical systems, subsystems and components. This is particularly critical for small spacecraft platforms. We will give an overview of some NASA applications for integrated photonics.

  17. Integrated circuit cell library

    Science.gov (United States)

    Whitaker, Sterling R. (Inventor); Miles, Lowell H. (Inventor)

    2005-01-01

    According to the invention, an ASIC cell library for use in creation of custom integrated circuits is disclosed. The ASIC cell library includes some first cells and some second cells. Each of the second cells includes two or more kernel cells. The ASIC cell library is at least 5% comprised of second cells. In various embodiments, the ASIC cell library could be 10% or more, 20% or more, 30% or more, 40% or more, 50% or more, 60% or more, 70% or more, 80% or more, 90% or more, or 95% or more comprised of second cells.

  18. Nano integrated circuit process

    International Nuclear Information System (INIS)

    Yoon, Yung Sup

    2004-02-01

    This book contains nine chapters, which are introduction of manufacture of semiconductor chip, oxidation such as Dry-oxidation, wet oxidation, oxidation model and oxide film, diffusion like diffusion process, diffusion equation, diffusion coefficient and diffusion system, ion implantation, including ion distribution, channeling, multiimplantation and masking and its system, sputtering such as CVD and PVD, lithography, wet etch and dry etch, interconnection and flattening like metal-silicon connection, silicide, multiple layer metal process and flattening, an integrated circuit process, including MOSFET and CMOS.

  19. Electronic logic circuits

    CERN Document Server

    Gibson, J

    2013-01-01

    Most branches of organizing utilize digital electronic systems. This book introduces the design of such systems using basic logic elements as the components. The material is presented in a straightforward manner suitable for students of electronic engineering and computer science. The book is also of use to engineers in related disciplines who require a clear introduction to logic circuits. This third edition has been revised to encompass the most recent advances in technology as well as the latest trends in components and notation. It includes a wide coverage of application specific integrate

  20. Linear integrated circuits

    CERN Document Server

    Carr, Joseph

    1996-01-01

    The linear IC market is large and growing, as is the demand for well trained technicians and engineers who understand how these devices work and how to apply them. Linear Integrated Circuits provides in-depth coverage of the devices and their operation, but not at the expense of practical applications in which linear devices figure prominently. This book is written for a wide readership from FE and first degree students, to hobbyists and professionals.Chapter 1 offers a general introduction that will provide students with the foundations of linear IC technology. From chapter 2 onwa

  1. Nano integrated circuit process

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yung Sup

    2004-02-15

    This book contains nine chapters, which are introduction of manufacture of semiconductor chip, oxidation such as Dry-oxidation, wet oxidation, oxidation model and oxide film, diffusion like diffusion process, diffusion equation, diffusion coefficient and diffusion system, ion implantation, including ion distribution, channeling, multiimplantation and masking and its system, sputtering such as CVD and PVD, lithography, wet etch and dry etch, interconnection and flattening like metal-silicon connection, silicide, multiple layer metal process and flattening, an integrated circuit process, including MOSFET and CMOS.

  2. Electronics circuits and systems

    CERN Document Server

    Bishop, Owen

    2011-01-01

    The material in Electronics - Circuits and Systems is a truly up-to-date textbook, with coverage carefully matched to the electronics units of the 2007 BTEC National Engineering and the latest AS and A Level specifications in Electronics from AQA, OCR and WJEC. The material has been organized with a logical learning progression, making it ideal for a wide range of pre-degree courses in electronics. The approach is student-centred and includes: numerous examples and activities; web research topics; Self Test features, highlighted key facts, formulae and definitions. Ea

  3. Optoelectronics circuits manual

    CERN Document Server

    Marston, R M

    1999-01-01

    This manual is a useful single-volume guide specifically aimed at the practical design engineer, technician, and experimenter, as well as the electronics student and amateur. It deals with the subject in an easy to read, down to earth, and non-mathematical yet comprehensive manner, explaining the basic principles and characteristics of the best known devices, and presenting the reader with many practical applications and over 200 circuits. Most of the ICs and other devices used are inexpensive and readily available types, with universally recognised type numbers.The second edition

  4. Optically controllable molecular logic circuits

    International Nuclear Information System (INIS)

    Nishimura, Takahiro; Fujii, Ryo; Ogura, Yusuke; Tanida, Jun

    2015-01-01

    Molecular logic circuits represent a promising technology for observation and manipulation of biological systems at the molecular level. However, the implementation of molecular logic circuits for temporal and programmable operation remains challenging. In this paper, we demonstrate an optically controllable logic circuit that uses fluorescence resonance energy transfer (FRET) for signaling. The FRET-based signaling process is modulated by both molecular and optical inputs. Based on the distance dependence of FRET, the FRET pathways required to execute molecular logic operations are formed on a DNA nanostructure as a circuit based on its molecular inputs. In addition, the FRET pathways on the DNA nanostructure are controlled optically, using photoswitching fluorescent molecules to instruct the execution of the desired operation and the related timings. The behavior of the circuit can thus be controlled using external optical signals. As an example, a molecular logic circuit capable of executing two different logic operations was studied. The circuit contains functional DNAs and a DNA scaffold to construct two FRET routes for executing Input 1 AND Input 2 and Input 1 AND NOT Input 3 operations on molecular inputs. The circuit produced the correct outputs with all possible combinations of the inputs by following the light signals. Moreover, the operation execution timings were controlled based on light irradiation and the circuit responded to time-dependent inputs. The experimental results demonstrate that the circuit changes the output for the required operations following the input of temporal light signals

  5. Sequential circuit design for radiation hardened multiple voltage integrated circuits

    Science.gov (United States)

    Clark, Lawrence T [Phoenix, AZ; McIver, III, John K.

    2009-11-24

    The present invention includes a radiation hardened sequential circuit, such as a bistable circuit, flip-flop or other suitable design that presents substantial immunity to ionizing radiation while simultaneously maintaining a low operating voltage. In one embodiment, the circuit includes a plurality of logic elements that operate on relatively low voltage, and a master and slave latches each having storage elements that operate on a relatively high voltage.

  6. Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements.

    Science.gov (United States)

    Carneiro, Grace Kelly Martins; Roque, Juliano Alves; Segundo, Aguinaldo Silva Garcez; Suzuki, Hideo

    2015-01-01

    The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip. Three types of active/interactive ceramic self-ligating brackets (n = 20) were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000), after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip. The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811). There were significant differences on stiffness among the three types of brackets (p = 0.005). The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle. Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation.

  7. Simple Cell Balance Circuit

    Science.gov (United States)

    Johnson, Steven D.; Byers, Jerry W.; Martin, James A.

    2012-01-01

    A method has been developed for continuous cell voltage balancing for rechargeable batteries (e.g. lithium ion batteries). A resistor divider chain is provided that generates a set of voltages representing the ideal cell voltage (the voltage of each cell should be as if the cells were perfectly balanced). An operational amplifier circuit with an added current buffer stage generates the ideal voltage with a very high degree of accuracy, using the concept of negative feedback. The ideal voltages are each connected to the corresponding cell through a current- limiting resistance. Over time, having the cell connected to the ideal voltage provides a balancing current that moves the cell voltage very close to that ideal level. In effect, it adjusts the current of each cell during charging, discharging, and standby periods to force the cell voltages to be equal to the ideal voltages generated by the resistor divider. The device also includes solid-state switches that disconnect the circuit from the battery so that it will not discharge the battery during storage. This solution requires relatively few parts and is, therefore, of lower cost and of increased reliability due to the fewer failure modes. Additionally, this design uses very little power. A preliminary model predicts a power usage of 0.18 W for an 8-cell battery. This approach is applicable to a wide range of battery capacities and voltages.

  8. Quantum-Circuit Refrigerator

    Science.gov (United States)

    MöTtöNen, Mikko; Tan, Kuan Y.; Masuda, Shumpei; Partanen, Matti; Lake, Russell E.; Govenius, Joonas; Silveri, Matti; Grabert, Hermann

    Quantum technology holds great potential in providing revolutionizing practical applications. However, fast and precise cooling of the functional quantum degrees of freedom on demand remains a major challenge in many solid-state implementations, such as superconducting circuits. We demonstrate direct cooling of a superconducting resonator mode using voltage-controllable quantum tunneling of electrons in a nanoscale refrigerator. In our first experiments on this type of a quantum-circuit refrigerator, we measure the drop in the mode temperature by electron thermometry at a resistor which is coupled to the resonator mode through ohmic losses. To eliminate unwanted dissipation, we remove the probe resistor and directly observe the power spectrum of the resonator output in agreement with the so-called P(E) theory. We also demonstrate in microwave reflection experiments that the internal quality factor of the resonator can be tuned by orders of magnitude. In the future, our refrigerator can be integrated with different quantum electric devices, potentially enhancing their performance. For example, it may prove useful in the initialization of superconducting quantum bits and in dissipation-assisted quantum annealing. We acknowledge European Research Council Grant SINGLEOUT (278117) and QUESS (681311) for funding.

  9. Quasi-Linear Circuit

    Science.gov (United States)

    Bradley, William; Bird, Ross; Eldred, Dennis; Zook, Jon; Knowles, Gareth

    2013-01-01

    This work involved developing spacequalifiable switch mode DC/DC power supplies that improve performance with fewer components, and result in elimination of digital components and reduction in magnetics. This design is for missions where systems may be operating under extreme conditions, especially at elevated temperature levels from 200 to 300 degC. Prior art for radiation-tolerant DC/DC converters has been accomplished utilizing classical magnetic-based switch mode converter topologies; however, this requires specific shielding and component de-rating to meet the high-reliability specifications. It requires complex measurement and feedback components, and will not enable automatic re-optimization for larger changes in voltage supply or electrical loading condition. The innovation is a switch mode DC/DC power supply that eliminates the need for processors and most magnetics. It can provide a well-regulated voltage supply with a gain of 1:100 step-up to 8:1 step down, tolerating an up to 30% fluctuation of the voltage supply parameters. The circuit incorporates a ceramic core transformer in a manner that enables it to provide a well-regulated voltage output without use of any processor components or magnetic transformers. The circuit adjusts its internal parameters to re-optimize its performance for changes in supply voltage, environmental conditions, or electrical loading at the output

  10. Effects of Tail Clipping on Larval Performance and Tail Regeneration Rates in the Near Eastern Fire Salamander, Salamandra infraimmaculata.

    Directory of Open Access Journals (Sweden)

    Ori Segev

    Full Text Available Tail-tip clipping is a common technique for collecting tissue samples from amphibian larvae and adults. Surprisingly, studies of this invasive sampling procedure or of natural tail clipping--i.e., bites inflicted by predators including conspecifics--on the performance and fitness of aquatic larval stages of urodeles are scarce. We conducted two studies in which we assessed the effects of posterior tail clipping (~30 percent of tail on Near Eastern fire salamander (Salamandra infraimmaculata larvae. In a laboratory study, we checked regeneration rates of posterior tail-tip clipping at different ages. Regeneration rates were hump-shaped, peaking at the age of ~30 days and then decreasing. This variation in tail regeneration rates suggests tradeoffs in resource allocation between regeneration and somatic growth during early and advanced development. In an outdoor artificial pond experiment, under constant larval densities, we assessed how tail clipping of newborn larvae affects survival to, time to, and size at metamorphosis. Repeated measures ANOVA on mean larval survival per pond revealed no effect of tail clipping. Tail clipping had correspondingly no effect on larval growth and development expressed in size (mass and snout-vent length at, and time to, metamorphosis. We conclude that despite the given variation in tail regeneration rates throughout larval ontogeny, clipping of 30% percent of the posterior tail area seems to have no adverse effects on larval fitness and survival. We suggest that future use of this imperative tool for the study of amphibian should take into account larval developmental stage during the time of application and not just the relative size of the clipped tail sample.

  11. Arithmetic circuits for DSP applications

    CERN Document Server

    Stouraitis, Thanos

    2017-01-01

    Arithmetic Circuits for DSP Applications is a complete resource on arithmetic circuits for digital signal processing (DSP). It covers the key concepts, designs and developments of different types of arithmetic circuits, which can be used for improving the efficiency of implementation of a multitude of DSP applications. Each chapter includes various applications of the respective class of arithmetic circuits along with information on the future scope of research. Written for students, engineers, and researchers in electrical and computer engineering, this comprehensive text offers a clear understanding of different types of arithmetic circuits used for digital signal processing applications. The text includes contributions from noted researchers on a wide range of topics, including a review o circuits used in implementing basic operations like additions and multiplications; distributed arithmetic as a technique for the multiplier-less implementation of inner products for DSP applications; discussions on look ...

  12. Integrated circuit cooled turbine blade

    Science.gov (United States)

    Lee, Ching-Pang; Jiang, Nan; Um, Jae Y.; Holloman, Harry; Koester, Steven

    2017-08-29

    A turbine rotor blade includes at least two integrated cooling circuits that are formed within the blade that include a leading edge circuit having a first cavity and a second cavity and a trailing edge circuit that includes at least a third cavity located aft of the second cavity. The trailing edge circuit flows aft with at least two substantially 180-degree turns at the tip end and the root end of the blade providing at least a penultimate cavity and a last cavity. The last cavity is located along a trailing edge of the blade. A tip axial cooling channel connects to the first cavity of the leading edge circuit and the penultimate cavity of the trailing edge circuit. At least one crossover hole connects the penultimate cavity to the last cavity substantially near the tip end of the blade.

  13. Control circuit for transformer relay

    International Nuclear Information System (INIS)

    Wyatt, G.A.

    1984-01-01

    A control circuit for a transformer relay which will automatically momentarily control the transformer relay to a selected state upon energization of the control circuit. The control circuit has an energy storage element and a current director coupled in series and adapted to be coupled with the secondary winding of the transformer relay. A device for discharge is coupled across the energy storage element. The energy storage element and current director will momentarily allow a unidirectional flow of current in the secondary winding of the transformer relay upon application of energy to the control circuit. When energy is not applied to the control circuit the device for discharge will allow the energy storage element to discharge and be available for another operation of the control circuit

  14. Source-circuit design overview

    Science.gov (United States)

    Ross, R. G., Jr.

    1983-01-01

    The source circuit is the fundamental electrical building block of a large central-station array; it consists of a series-parallel network of solar cells that develops full system voltage. The array field is generally made up of a large number of parallel source circuits. Source-circuit electrical configuration is driven by a number of design considerations, which must be considered simultaneously. Array fault tolerance and hot spot heating endurance are examined in detail.

  15. Use of a surgical rehearsal platform and improvement in aneurysm clipping measures: results of a prospective, randomized trial.

    Science.gov (United States)

    Chugh, A Jessey; Pace, Jonathan R; Singer, Justin; Tatsuoka, Curtis; Hoffer, Alan; Selman, Warren R; Bambakidis, Nicholas C

    2017-03-01

    OBJECTIVE The field of neurosurgery is constantly undergoing improvements and advances, both in technique and technology. Cerebrovascular neurosurgery is no exception, with endovascular treatments changing the treatment paradigm. Clipping of aneurysms is still necessary, however, and advances are still being made to improve patient outcomes within the microsurgical treatment of aneurysms. Surgical rehearsal platforms are surgical simulators that offer the opportunity to rehearse a procedure prior to entering the operative suite. This study is designed to determine whether use of a surgical rehearsal platform in aneurysm surgery is helpful in decreasing aneurysm dissection time and clip manipulation of the aneurysm. METHODS The authors conducted a blinded, prospective, randomized study comparing key effort and time variables in aneurysm clip ligation surgery with and without preoperative use of the SuRgical Planner (SRP) surgical rehearsal platform. Initially, 40 patients were randomly assigned to either of two groups: one in which surgery was performed after use of the SRP (SRP group) and one in which surgery was performed without use of the SRP (control group). All operations were videotaped. After exclusion of 6 patients from the SRP group and 9 from the control group, a total of 25 surgical cases were analyzed by a reviewer blinded to group assignment. The videos were analyzed for total microsurgical time, number of clips used, and number of clip placement attempts. Means and standard deviations (SDs) were calculated and compared between groups. RESULTS The mean (± SD) amount of operative time per clip used was 920 ± 770 seconds in the SRP group and 1294 ± 678 seconds in the control group (p = 0.05). In addition, the mean values for the number of clip attempts, total operative time, ratio of clip attempts to clips used, and time per clip attempt were all lower in the SRP group, although the between-group differences were not statistically significant

  16. Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling

    Science.gov (United States)

    Shen, Guangping; Zhang, Songning; Bennett, Hunter J.; Martin, James C.; Crouter, Scott E.; Fitzhugh, Eugene C.

    2018-01-01

    Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling. Key points Varus or valgus alignment did not cause increased frontal-plane knee joint loading, suggesting stationary cycling is a safe exercise. This study supports that using a toe clip did not lead to abnormal frontal-plane knee loading during stationary cycling. Two different knee frontal plane loading patterns, knee abduction and adduction moment, were observed during stationary cycling, which are likely affected by

  17. Aneurysmal subarachnoid hemorrhage: outcome of aneurysm clipping versus coiling in anterior circulation aneurysm

    International Nuclear Information System (INIS)

    Wadd, I.H.; Haroon, A.; Ansari, S.

    2015-01-01

    To compare the neurological outcome of microsurgical clipping versus coiling in patients with anterior circulation aneurysm. Study Design: Comparative study. Place and Duration of Study: Department of Neurosurgery, Lahore General Hospital, Lahore, from January 2010 to December 2013. Methodology: Patients aged 14 - 60 years, with ruptured cerebral aneurysm of anterior circulation and World Federation of Neurosurgical Society (WFNS) grades 1, 2 and 3 were included. Patients more than 60 years, medically unfit patient and posterior circulation aneurysms and WFNS grades 4 and 5 were excluded. Aneurysm sac obliteration was done in randomized manner with microsurgical clipping or coiling. Postoperatively, the patients were assessed and followed-up upto one year for outcome parameters on the bases of WFNS grade and Modified Ranking Scale (mRS) as favourable (mRS =2 ) and unfavourable (mRS > 2). Results: Among 140 subjects selected for study, 70 were included in group A, i.e. coiling and other 70 were in group B, i.e. clipping. The median age of patients in group A was 52.5 ± 10 years and in group B was 51.00 ± years. Overall, 56 (40%) males, 28 (60%) males in each group; and 84 (60%) females, 42 (60%) in each group were included. The male to female ratio in this study was 1:1.5. In group A, i.e. coiling, 27 (38.6%) patients had no disability (grades 1 and 2), 25 (35.7%) were slightly disabled (grade 3) and 18 (25.7%) had moderate disability (grade 4); whereas in group B, i.e. clipping group 23 (32.9%) patients had no disability (grades 1 and 2), 23 (32.9%) were slightly disabled (grade 3) and 24 (34.3%) had moderate disability (grade 4). At one year follow-up, in group A, favourable outcome was achieved in 56 (80%) of patients compared to 48 (68.6%) in group B; whilst, 14 (20%) patients in group A and 22 (33.1%) in group B showed unfavourable outcome. Although mortality rate was higher in clipping (n=3, 4.3%) as compared to coiling (n=1, 1.4%), but was not statistically

  18. Radiation-sensitive switching circuits

    Energy Technology Data Exchange (ETDEWEB)

    Moore, J.H.; Cockshott, C.P.

    1976-03-16

    A radiation-sensitive switching circuit has a light emitting diode which supplies light to a photo-transistor, the light being interrupted from time to time. When the photo-transistor is illuminated, current builds up and when this current reaches a predetermined value, a trigger circuit changes state. The peak output of the photo-transistor is measured and the trigger circuit is arranged to change state when the output of the device is a set proportion of the peak output, so as to allow for aging of the components. The circuit is designed to control the ignition system in an automobile engine.

  19. Four-junction superconducting circuit

    Science.gov (United States)

    Qiu, Yueyin; Xiong, Wei; He, Xiao-Ling; Li, Tie-Fu; You, J. Q.

    2016-01-01

    We develop a theory for the quantum circuit consisting of a superconducting loop interrupted by four Josephson junctions and pierced by a magnetic flux (either static or time-dependent). In addition to the similarity with the typical three-junction flux qubit in the double-well regime, we demonstrate the difference of the four-junction circuit from its three-junction analogue, including its advantages over the latter. Moreover, the four-junction circuit in the single-well regime is also investigated. Our theory provides a tool to explore the physical properties of this four-junction superconducting circuit. PMID:27356619

  20. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (DEC VAX VMS VERSION)

    Science.gov (United States)

    Donnell, B.

    1994-01-01

    CLIPS, the C Language Integrated Production System, is a complete environment for developing expert systems -- programs which are specifically intended to model human expertise or knowledge. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. CLIPS 6.0 provides a cohesive tool for handling a wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. Rule-based programming allows knowledge to be represented as heuristics, or "rules-of-thumb" which specify a set of actions to be performed for a given situation. Object-oriented programming allows complex systems to be modeled as modular components (which can be easily reused to model other systems or create new components). The procedural programming capabilities provided by CLIPS 6.0 allow CLIPS to represent knowledge in ways similar to those allowed in languages such as C, Pascal, Ada, and LISP. Using CLIPS 6.0, one can develop expert system software using only rule-based programming, only object-oriented programming, only procedural programming, or combinations of the three. CLIPS provides extensive features to support the rule-based programming paradigm including seven conflict resolution strategies, dynamic rule priorities, and truth maintenance. CLIPS 6.0 supports more complex nesting of conditional elements in the if portion of a rule ("and", "or", and "not" conditional elements can be placed within a "not" conditional element). In addition, there is no longer a limitation on the number of multifield slots that a deftemplate can contain. The CLIPS Object-Oriented Language (COOL) provides object-oriented programming capabilities. Features supported by COOL include classes with multiple inheritance, abstraction, encapsulation, polymorphism, dynamic binding, and message passing with message-handlers. CLIPS 6.0 supports tight integration of the rule-based programming features of CLIPS with

  1. Memristor Circuits and Systems

    KAUST Repository

    Zidan, Mohammed A.

    2015-05-01

    Current CMOS-based technologies are facing design challenges related to the continuous scaling down of the minimum feature size, according to Moore’s law. Moreover, conventional computing architecture is no longer an effective way of fulfilling modern applications demands, such as big data analysis, pattern recognition, and vector processing. Therefore, there is an exigent need to shift to new technologies, at both the architecture and the device levels. Recently, memristor devices and structures attracted attention for being promising candidates for this job. Memristor device adds a new dimension for designing novel circuits and systems. In addition, high-density memristor-based crossbar is widely considered to be the essential element for future memory and bio-inspired computing systems. However, numerous challenges need to be addressed before the memristor genuinely replaces current memory and computing technologies, which is the motivation behind this research effort. In order to address the technology challenges, we begin by fabricating and modeling the memristor device. The devices fabricated at our local clean room enriched our understanding of the memristive phenomenon and enabled the experimental testing for our memristor-based circuits. Moreover, our proposed mathematical modeling for memristor behavior is an essential element for the theoretical circuit design stage. Designing and addressing the challenges of memristor systems with practical complexity, however, requires an extra step, which takes the form of a reliable and modular simulation platform. We, therefore, built a new simulation platform for the resistive crossbar, which can simulate realistic size arrays filled with real memory data. In addition, this simulation platform includes various crossbar nonidealities in order to obtain accurate simulation results. Consequently, we were able to address the significant challenges facing the high density memristor crossbar, as the building block for

  2. Basic electronic circuits

    CERN Document Server

    Buckley, P M

    1980-01-01

    In the past, the teaching of electricity and electronics has more often than not been carried out from a theoretical and often highly academic standpoint. Fundamentals and basic concepts have often been presented with no indication of their practical appli­ cations, and all too frequently they have been illustrated by artificially contrived laboratory experiments bearing little relationship to the outside world. The course comes in the form of fourteen fairly open-ended constructional experiments or projects. Each experiment has associated with it a construction exercise and an explanation. The basic idea behind this dual presentation is that the student can embark on each circuit following only the briefest possible instructions and that an open-ended approach is thereby not prejudiced by an initial lengthy encounter with the theory behind the project; this being a sure way to dampen enthusiasm at the outset. As the investigation progresses, questions inevitably arise. Descriptions of the phenomena encounte...

  3. ECCS control circuit

    International Nuclear Information System (INIS)

    Sato, Takashi.

    1986-01-01

    Purpose: To afford a sufficient margin to pressure vibrations upon starting of an automatic depressurization system by dispersing pressure vibration in suppression water due to the opening action of an automatic releaf valve in the automatic depressurization system thereby reducing the dynamic load exerted to the surface of the suppression walls. Constitution: Upon occurrence of loss of coolant accidents, an automatic releaf valve for automatic depressurization is opened to deliver the steams in the pressure vessel into the suppression pool. Since a plurality of automatic releaf valves have usually been disposed, if they are opened simultaneously, excess dynamic loads are exerted due to the pressure vibrations to the wall surface of the suppression pool. In this invention, a control circuit is disposed such that the opening timing for each of the automatic releaf valves is deviated upon occurrence of a driving signal for the automatic depressurization system to thereby disperse the pressure vibrations in the suppression water. (Kamimura, M.)

  4. A dishwasher for circuits

    CERN Multimedia

    Rosaria Marraffino

    2014-01-01

    You have always been told that electronic devices fear water. However, at the Surface Mount Devices (SMD) Workshop here at CERN all the electronic assemblies are cleaned with a machine that looks like a… dishwasher.   The circuit dishwasher. Credit: Clara Nellist.  If you think the image above shows a dishwasher, you wouldn’t be completely wrong. Apart from the fact that the whole pumping system and the case itself are made entirely from stainless steel and chemical resistant materials, and the fact that it washes electrical boards instead of dishes… it works exactly like a dishwasher. It’s a professional machine (mainly used in the pharmaceutical industry) designed to clean everything that can be washed with a water-based chemical soap. This type of treatment increases the lifetime of the electronic boards and therefore the LHC's reliability by preventing corrosion problems in the severe radiation and ozone environment of the LHC tunn...

  5. Modeling cortical circuits.

    Energy Technology Data Exchange (ETDEWEB)

    Rohrer, Brandon Robinson; Rothganger, Fredrick H.; Verzi, Stephen J.; Xavier, Patrick Gordon

    2010-09-01

    The neocortex is perhaps the highest region of the human brain, where audio and visual perception takes place along with many important cognitive functions. An important research goal is to describe the mechanisms implemented by the neocortex. There is an apparent regularity in the structure of the neocortex [Brodmann 1909, Mountcastle 1957] which may help simplify this task. The work reported here addresses the problem of how to describe the putative repeated units ('cortical circuits') in a manner that is easily understood and manipulated, with the long-term goal of developing a mathematical and algorithmic description of their function. The approach is to reduce each algorithm to an enhanced perceptron-like structure and describe its computation using difference equations. We organize this algorithmic processing into larger structures based on physiological observations, and implement key modeling concepts in software which runs on parallel computing hardware.

  6. Inductive circuit arrangements

    International Nuclear Information System (INIS)

    Mansfield, Peter; Coxon, R.J.

    1987-01-01

    A switched coil arrangement is connected in a bridge configuration of four switches S 1 , S 2 , S 3 and S 4 which are each shunted by diodes D 1 , D 2 , D 3 and D 4 so that current can flow in either direction through a coil L depending on the setting of the switches. A capacitor C is connected across the bridge through a switch S 5 to receive the inductive energy stored in coil L on breaking the current flow path through the coil. The electrostatic energy stored in capacitor C can then be used to supply current through the coil in the reverse direction either immediately or after a time delay. Coil L may be a superconductive coil. Losses in the circuit can be made up by a trickle charge of capacitor C from a separate supply V 2 . The device may be used in nuclear magnetic resonance imaging. (author)

  7. Postoperative three-dimensional CT angiography after cerebral aneurysm clipping with titanium clips: detection with single detector CT. Comparison with intra-arterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Sakuma, I.; Tomura, N.; Kinouchi, H.; Takahashi, S.; Otani, T.; Watarai, J.; Mizoi, K.

    2006-01-01

    AIM: To assess the significance of three-dimensional computed tomography angiography (3D-CTA) in detecting remnant necks after cerebral aneurysm clipping. MATERIALS AND METHODS: A total of 59 patients (77 aneurysms) underwent surgery using titanium clips. Two blinded observers independently evaluated the presence of neck remnants on shaded-surface display (SSD) imaging, volume rendered (VR) imaging, and intra-arterial digital subtraction angiography (IADSA). RESULTS: Mean sensitivity and specificity for detecting neck remnants were 50.0 and 74.2% for SSD imaging, 61.5 and 82.8% for VR imaging, and 92.3 and 92.2% for IADSA, respectively. Receiver operating characteristic (ROC) analysis revealed excellent diagnostic performance for IADSA [mean area under ROC curve (Az)=0.97], and good diagnostic performance for 3D-CTA (Az=0.70 and 0.76 for SSD and VR, respectively). Specificity of VR was better than that SSD (p=0.082), however, there was no significant difference between them. CONCLUSION: Use of 3D-CTA techniques can facilitate postoperative evaluation

  8. Integrating knowledge and control into hypermedia-based training environments: Experiments with HyperCLIPS

    Science.gov (United States)

    Hill, Randall W., Jr.

    1990-01-01

    The issues of knowledge representation and control in hypermedia-based training environments are discussed. The main objective is to integrate the flexible presentation capability of hypermedia with a knowledge-based approach to lesson discourse management. The instructional goals and their associated concepts are represented in a knowledge representation structure called a 'concept network'. Its functional usages are many: it is used to control the navigation through a presentation space, generate tests for student evaluation, and model the student. This architecture was implemented in HyperCLIPS, a hybrid system that creates a bridge between HyperCard, a popular hypertext-like system used for building user interfaces to data bases and other applications, and CLIPS, a highly portable government-owned expert system shell.

  9. Microanalysis on selected video clips with focus on communicative response in music therapy

    DEFF Research Database (Denmark)

    Ridder, Hanne Mette Ochsner

    2007-01-01

    This chapter describes a five-step procedure for video analysis where the topic of investigation is the communicative response of clients in music therapy. In this microanalysis procedure only very short video clips are used, and in order to select these clips an overview of each music therapy...... session is obtained with the help of a session-graph that is a systematic way of collecting video observations from one music therapy session and combining the data in one figure. The systematic procedures do not demand sophisticated computer equipment; only standard programmes such as Excel and a media...... player. They are based on individual music therapy work with a population who are difficult to engage in joint activities and who show little response (e.g. persons suffering from severe dementia). The video analysis tools might be relevant to other groups of clients where it is important to form a clear...

  10. A combination of selected mapping and clipping to increase energy efficiency of OFDM systems

    Science.gov (United States)

    Lee, Byung Moo; Rim, You Seung

    2017-01-01

    We propose an energy efficient combination design for OFDM systems based on selected mapping (SLM) and clipping peak-to-average power ratio (PAPR) reduction techniques, and show the related energy efficiency (EE) performance analysis. The combination of two different PAPR reduction techniques can provide a significant benefit in increasing EE, because it can take advantages of both techniques. For the combination, we choose the clipping and SLM techniques, since the former technique is quite simple and effective, and the latter technique does not cause any signal distortion. We provide the structure and the systematic operating method, and show the various analyzes to derive the EE gain based on the combined technique. Our analysis show that the combined technique increases the EE by 69% compared to no PAPR reduction, and by 19.34% compared to only using SLM technique. PMID:29023591

  11. Three-port laparoscopic cholecystectomy by harmonic dissection without cystic duct and artery clipping.

    Science.gov (United States)

    Tebala, Giovanni D

    2006-05-01

    The technique of laparoscopic cholecystectomy (LC) still has areas of refinements. To decrease the number of ports, a cannula may be replaced by a percutaneous suture suspension of the gallbladder. The risk of tissue injury caused by repeat blind extraction and insertion of various instruments in and out of the abdomen may be decreased by the use of the multipurpose harmonic dissector. One hundred consecutive patients with symptomatic cholelithiasis underwent 3-port LC entirely performed by harmonic dissector without cystic duct and artery clipping. In 8 cases, a fourth trocar was necessary. In 2 cases, the cystic duct was clipped after an unsafe ultrasound sealing. In 1 case, continuous bleeding from the liver required the use of diathermy. No common bile duct injury was registered. The 3-port harmonic LC is a feasible, effective, and safe technique.

  12. Use of activation analysis method for determining trace elements in human nail clippings

    International Nuclear Information System (INIS)

    Aguiar, Amilton Reinaldo; Saiki, Mitiko

    1999-01-01

    This work presents results obtained in nail clipping samples analyses. These nail samples were collected from healthy group of individuals and from patients with cystic fibrosis disease. Irradiation of nail clippings was carried out with a thermal neutron flux from 10 11 to 10 13 n.cm -2 .s -1 at the IEA-R1m nuclear research reactor and the elements Al, As, Br, Ca, cd, Cl, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Se and Zn were determined. The results obtained for healthy group were within the range of concentrations published, for normal population. However for several elements, the group of patients presented higher concentrations than those presented for healthy individuals. The precision and the accuracy of the results were evaluated by analyzing reference materials NIST 1577b Bovine Liver and 1566a Oyster Tissue. (author)

  13. Cryoablation of lung malignancies recurring close to surgical clips following surgery: Report of three cases

    International Nuclear Information System (INIS)

    Grasso, Rosario F; Luppi, Giacomo; Cazzato, Roberto L; Vescovo, Riccardo Del; Giurazza, Francesco; Mercurio, Simona; Faiella, Eliodoro; Zobel, Bruno Beomonte

    2015-01-01

    Minimally ablative therapies are now available for the treatment of lung malignancies. However, selection of the appropriate technique is not always easy and requires accurate preoperative planning. To describe the treatment of lung tumors with cryoablation. We report three cases of lung malignancies that recurred close to surgical clips after surgical treatment, successfully treated by cryoablation. An initial freezing cycle was performed for 10 min, followed by a 5-min thawing cycle, and an additional 10-min freezing cycle. A final 5-min thaw was necessary to remove the needle from the iceball formed during the freezing cycle. The procedures were completed successfully with no signs of surgical-clip misplacement, and excellent ablation of the lesions. Cryoablation is a relatively new procedure that potentially permits the local treatment of lung tumors with minimal loss of lung parenchyma

  14. Results from extrapleural clipping of a patent ductus arteriosus in seriously ill preterm infants.

    Science.gov (United States)

    Demirturk, Orhan; Güvener, Murat; Coşkun, Isa; Tünel, Hüseyin Ali

    2011-12-01

    Minithoracotomy for extrapleural closure of the patent ductus arteriosus (PDA) in seriously ill patients offers a fast and less invasive alternative to conventional transpleural ductal closure. This study reports the immediate postoperative clinical outcomes for 24 extrapleurally clipped premature infants presenting with congestive heart failure in high-risk comorbidity status between March 2007 and November 2010. The demographics, preoperative clinical characteristics, and postoperative outcomes of the patients, including echocardiographic assessments, were evaluated. No surgery-related mortalities occurred. Four mortalities occurred after surgery due to sepsis and bleeding diathesis. All 20 surviving patients exhibited normal left ventricular dimensions and systolic function in the immediate follow-up period. The study shows that extrapleural clip closure in seriously ill premature infants has an acceptable overall short-term mortality and complication rate with a high rate of ductal closure.

  15. The role of surgical clips in the evaluation of interfractional uncertainty for treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy

    International Nuclear Information System (INIS)

    Bae, Jin Suk; Kim, Dong Hyun; Kim, Won Taek; Kim, Yong Ho; Park, Dahl; Ki, Yong Kan

    2017-01-01

    To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip_p, ≤2 cm) and 3 distal clips (clip_d, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions. The translocation of clip was well correlated with diaphragm movement in 90.4% (190/210) of all images. The clip position errors greater than 5 mm were observed in 26.0% in SI, 1.8% in AP, and 5.4% in RL directions, respectively. Moreover, the clip position errors greater than 10 mm were observed in 1.9% in SI, 0.2% in AP, and 0.2% in RL directions, despite respiratory control. Quantitative analysis of surgical clip displacement reflect respiratory motion, setup errors and postoperative change of intraabdominal organ position. Furthermore, position of clips is distinguished easily in verification images. The identification of the surgical clip position may lead to a significant improvement in the accuracy of upper abdominal radiation therapy

  16. The role of surgical clips in the evaluation of interfractional uncertainty for treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jin Suk; Kim, Dong Hyun; Kim, Won Taek; Kim, Yong Ho; Park, Dahl; Ki, Yong Kan [Pusan National University Hospital, Pusan National University School of Medicine, Busan (Korea, Republic of)

    2017-03-15

    To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip{sub p}, ≤2 cm) and 3 distal clips (clip{sub d}, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions. The translocation of clip was well correlated with diaphragm movement in 90.4% (190/210) of all images. The clip position errors greater than 5 mm were observed in 26.0% in SI, 1.8% in AP, and 5.4% in RL directions, respectively. Moreover, the clip position errors greater than 10 mm were observed in 1.9% in SI, 0.2% in AP, and 0.2% in RL directions, despite respiratory control. Quantitative analysis of surgical clip displacement reflect respiratory motion, setup errors and postoperative change of intraabdominal organ position. Furthermore, position of clips is distinguished easily in verification images. The identification of the surgical clip position may lead to a significant improvement in the accuracy of upper abdominal radiation therapy.

  17. Virtual Reality Cerebral Aneurysm Clipping Simulation With Real-time Haptic Feedback

    Science.gov (United States)

    Alaraj, Ali; Luciano, Cristian J.; Bailey, Daniel P.; Elsenousi, Abdussalam; Roitberg, Ben Z.; Bernardo, Antonio; Banerjee, P. Pat; Charbel, Fady T.

    2014-01-01

    Background With the decrease in the number of cerebral aneurysms treated surgically and the increase of complexity of those treated surgically, there is a need for simulation-based tools to teach future neurosurgeons the operative techniques of aneurysm clipping. Objective To develop and evaluate the usefulness of a new haptic-based virtual reality (VR) simulator in the training of neurosurgical residents. Methods A real-time sensory haptic feedback virtual reality aneurysm clipping simulator was developed using the Immersive Touch platform. A prototype middle cerebral artery aneurysm simulation was created from a computed tomography angiogram. Aneurysm and vessel volume deformation and haptic feedback are provided in a 3-D immersive VR environment. Intraoperative aneurysm rupture was also simulated. Seventeen neurosurgery residents from three residency programs tested the simulator and provided feedback on its usefulness and resemblance to real aneurysm clipping surgery. Results Residents felt that the simulation would be useful in preparing for real-life surgery. About two thirds of the residents felt that the 3-D immersive anatomical details provided a very close resemblance to real operative anatomy and accurate guidance for deciding surgical approaches. They believed the simulation is useful for preoperative surgical rehearsal and neurosurgical training. One third of the residents felt that the technology in its current form provided very realistic haptic feedback for aneurysm surgery. Conclusion Neurosurgical residents felt that the novel immersive VR simulator is helpful in their training especially since they do not get a chance to perform aneurysm clippings until very late in their residency programs. PMID:25599200

  18. Resolution of Oculomotor Nerve Palsy Secondary to Posterior Communicating Artery Aneurysms: Comparison of Clipping and Coiling.

    Science.gov (United States)

    McCracken, D Jay; Lovasik, Brendan P; McCracken, Courtney E; Caplan, Justin M; Turan, Nefize; Nogueira, Raul G; Cawley, C Michael; Dion, Jacques E; Tamargo, Rafael J; Barrow, Daniel L; Pradilla, Gustavo

    2015-12-01

    Previous studies have attempted to determine the best treatment for oculomotor nerve palsy (ONP) secondary to posterior communicating artery (PCoA) aneurysms, but have been limited by small sample sizes and limited treatment. To analyze the treatment of ONP secondary to PCoA with both coiling and clipping in ruptured and unruptured aneurysms. Data from 2 large academic centers was retrospectively collected over 22 years, yielding a total of 93 patients with ONP secondary to PCoA aneurysms. These patients were combined with 321 patients from the literature review for large data analyses. Onset symptoms, recovery, and time to resolution were evaluated with respect to treatment and aneurysm rupture status. For all patients presenting with ONP (n = 414) 56.6% of those treated with microsurgical clipping made a full recovery vs 41.5% of those treated with endovascular coil embolization (P = .02). Of patients with a complete ONP (n = 229), full recovery occurred in 47.3% of those treated with clipping but in only 20% of those undergoing coiling (P = .01). For patients presenting with ruptured aneurysms (n = 130), full recovery occurred in 70.9% compared with 49.3% coiled patients (P = .01). Additionally, although patients with full ONP recovery had a median time to treatment of 4 days, those without full ONP recovery had a median time to treatment of 7 days (P = .01). Patients with ONP secondary to PCoA aneurysms treated with clipping showed higher rates of full ONP resolution than patients treated with coil embolization. Larger prospective studies are needed to determine the true potential of recovery associated with each treatment. EUH, Emory University HospitalIQR, interquartile rangeJHU, Johns Hopkins UniversitymRS, modified Rankin ScaleONP, oculomotor nerve palsyPCoA, posterior communicating arterySAH, subarachnoid hemorrhage.

  19. Occipital Artery Function during the Development of 2-Kidney, 1-Clip Hypertension in Rats

    OpenAIRE

    Stephen P. Chelko; Chad W. Schmiedt; Tristan H. Lewis; Tom P. Robertson; Stephen J. Lewis

    2014-01-01

    This study compared the contractile responses elicited by angiotensin II (AII), arginine vasopressin (AVP), and 5-hydroxytryptamine (5-HT) in isolated occipital arteries (OAs) from sham-operated (SHAM) and 2-kidney, 1-clip (2K-1C) hypertensive rats. OAs were isolated and bisected into proximal segments (closer to the common carotid artery) and distal segments (closer to the nodose ganglion) and mounted separately on myographs. On day 9, 2K-1C rats had higher mean arterial blood pressures, hea...

  20. The contribution of CLIP2 haploinsufficiency to the clinical manifestations of the Williams-Beuren syndrome.

    Science.gov (United States)

    Vandeweyer, Geert; Van der Aa, Nathalie; Reyniers, Edwin; Kooy, R Frank

    2012-06-08

    Williams-Beuren syndrome is a rare contiguous gene syndrome, characterized by intellectual disability, facial dysmorphisms, connective-tissue abnormalities, cardiac defects, structural brain abnormalities, and transient infantile hypercalcemia. Genes lying telomeric to RFC2, including CLIP2, GTF2I and GTF2IRD1, are currently thought to be the most likely major contributors to the typical Williams syndrome cognitive profile, characterized by a better-than-expected auditory rote-memory ability, a relative sparing of language capabilities, and a severe visual-spatial constructive impairment. Atypical deletions in the region have helped to establish genotype-phenotype correlations. So far, however, hardly any deletions affecting only a single gene in the disease region have been described. We present here two healthy siblings with a pure, hemizygous deletion of CLIP2. A putative role in the cognitive and behavioral abnormalities seen in Williams-Beuren patients has been suggested for this gene on the basis of observations in a knock-out mouse model. The presented siblings did not show any of the clinical features associated with the syndrome. Cognitive testing showed an average IQ for both and no indication of the Williams syndrome cognitive profile. This shows that CLIP2 haploinsufficiency by itself does not lead to the physical or cognitive characteristics of the Williams-Beuren syndrome, nor does it lead to the Williams syndrome cognitive profile. Although contribution of CLIP2 to the phenotype cannot be excluded when it is deleted in combination with other genes, our results support the hypothesis that GTF2IRD1 and GTF2I are the main genes causing the cognitive defects associated with Williams-Beuren syndrome. Copyright © 2012 The American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  1. Microsurgical clipping of ophthalmic artery aneurysms: surgical results and visual outcomes with 208 aneurysms.

    Science.gov (United States)

    Kamide, Tomoya; Tabani, Halima; Safaee, Michael M; Burkhardt, Jan-Karl; Lawton, Michael T

    2018-01-26

    OBJECTIVE While most paraclinoid aneurysms can be clipped with excellent results, new postoperative visual deficits are a concern. New technology, including flow diverters, has increased the popularity of endovascular therapy. However, endovascular treatment of paraclinoid aneurysms is not without procedural risks, is associated with higher rates of incomplete aneurysm occlusion and recurrence, and may not address optic nerve compression symptoms that surgical debulking can. The increasing endovascular management of paraclinoid aneurysms should be justified by comparisons to surgical benchmarks. The authors, therefore, undertook this study to define patient, visual, and aneurysm outcomes in the most common type of paraclinoid aneurysm: ophthalmic artery (OphA) aneurysms. METHODS Results from microsurgical clipping of 208 OphA aneurysms in 198 patients were retrospectively reviewed. Patient demographics, aneurysm morphology (size, calcification, etc.), clinical characteristics, and patient outcomes were recorded and analyzed. RESULTS Despite 20% of these aneurysms being large or giant in size, complete aneurysm occlusion was accomplished in 91% of 208 cases, with OphA patency preserved in 99.5%. The aneurysm recurrence rate was 3.1% and the retreatment rate was 0%. Good outcomes (modified Rankin Scale score 0-2) were observed in 96.2% of patients overall and in all 156 patients with unruptured aneurysms. New visual field defects (hemianopsia or quadrantanopsia) were observed in 8 patients (3.8%), decreased visual acuity in 5 (2.4%), and monocular blindness in 9 (4.3%). Vision improved in 9 (52.9%) of the 17 patients with preoperative visual deficits. CONCLUSIONS The most important risk associated with clipping OphA aneurysms is a new visual deficit. Meticulous microsurgical technique is necessary during anterior clinoidectomy, aneurysm dissection, and clip application to optimize visual outcomes, and aggressive medical management postoperatively might potentially

  2. Compact Circuit Preprocesses Accelerometer Output

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1993-01-01

    Compact electronic circuit transfers dc power to, and preprocesses ac output of, accelerometer and associated preamplifier. Incorporated into accelerometer case during initial fabrication or retrofit onto commercial accelerometer. Made of commercial integrated circuits and other conventional components; made smaller by use of micrologic and surface-mount technology.

  3. Comminution circuits for compact itabirites

    Directory of Open Access Journals (Sweden)

    Pedro Ferreira Pinto

    Full Text Available Abstract In the beneficiation of compact Itabirites, crushing and grinding account for major operational and capital costs. As such, the study and development of comminution circuits have a fundamental importance for feasibility and optimization of compact Itabirite beneficiation. This work makes a comparison between comminution circuits for compact Itabirites from the Iron Quadrangle. The circuits developed are: a crushing and ball mill circuit (CB, a SAG mill and ball mill circuit (SAB and a single stage SAG mill circuit (SSSAG. For the SAB circuit, the use of pebble crushing is analyzed (SABC. An industrial circuit for 25 million tons of run of mine was developed for each route from tests on a pilot scale (grinding and industrial scale. The energy consumption obtained for grinding in the pilot tests was compared with that reported by Donda and Bond. The SSSAG route had the lowest energy consumption, 11.8kWh/t and the SAB route had the highest energy consumption, 15.8kWh/t. The CB and SABC routes had a similar energy consumption of 14.4 kWh/t and 14.5 kWh/t respectively.

  4. Current-mode minimax circuit

    NARCIS (Netherlands)

    Wassenaar, R.F.

    1992-01-01

    The minimum-maximum (minimax) circuit selects the minimum and maximum of two input currents. Four transistors in matched pairs are operated in the saturation region. Because the behavior of the circuit is based on matched devices and is independent of the relationship between the drain current and

  5. Short-circuit impedance measurement

    DEFF Research Database (Denmark)

    Pedersen, Knud Ole Helgesen; Nielsen, Arne Hejde; Poulsen, Niels Kjølstad

    2003-01-01

    Methods for estimating the short-circuit impedance in the power grid are investigated for various voltage levels and situations. The short-circuit impedance is measured, preferably from naturally occurring load changes in the grid, and it is shown that such a measurement system faces different...

  6. Cell short circuit, preshort signature

    Science.gov (United States)

    Lurie, C.

    1980-01-01

    Short-circuit events observed in ground test simulations of DSCS-3 battery in-orbit operations are analyzed. Voltage signatures appearing in the data preceding the short-circuit event are evaluated. The ground test simulation is briefly described along with performance during reconditioning discharges. Results suggest that a characteristic signature develops prior to a shorting event.

  7. Enhancement of Linear Circuit Program

    DEFF Research Database (Denmark)

    Gaunholt, Hans; Dabu, Mihaela; Beldiman, Octavian

    1996-01-01

    In this report a preliminary user friendly interface has been added to the LCP2 program making it possible to describe an electronic circuit by actually drawing the circuit on the screen. Component values and other options and parameters can easily be set by the aid of the interface. The interface...

  8. Predicting Factors of Chronic Subdural Hematoma Following Surgical Clipping in Unruptured and Ruptured Intracranial Aneurysm.

    Science.gov (United States)

    Kwon, Min-Yong; Kim, Chang-Hyun; Lee, Chang-Young

    2016-09-01

    The aim of this study is to analyze the differences in the incidence, predicting factors, and clinical course of chronic subdural hematoma (CSDH) following surgical clipping between unruptured (UIA) and ruptured intracranial aneurysm (RIA). We conducted a retrospective analysis of 752 patients (UIA : 368 and RIA : 384) who underwent surgical clipping during 8 years. The incidence and predicting factors of CSDH development in the UIA and RIA were compared according to medical records and radiological data. The incidence of postoperative CSDH was higher in the UIA (10.9%) than in the RIA (3.1%) (p=0.000). In multivariate analysis, a high Hounsfield (HF) unit (blood clots) for subdural fluid collection (SFC), persistence of SFC ≥5 mm and male sex in the UIA and A high HF unit for SFC and SFC ≥5 mm without progression to hydrocephalus in the RIA were identified as the independent predicting factors for CSDH development (psubdural space and persistence of SFC ≥5 mm were predicting factors in both UIA and RIA. However, progression to hydrocephalus may have in part contributed to low CSDH development in the RIA. We suggest that cleaning of blood clots in the subdural space and efforts to minimize SFC ≥5 mm at the end of surgery is helpful to prevent CSDH following aneurysmal clipping.

  9. Establishing a protocol for element determination in human nail clippings by neutron activation analysis

    International Nuclear Information System (INIS)

    Sanches, Thalita Pinheiro; Saiki, Mitiko

    2011-01-01

    Human nail samples have been analyzed to evaluate occupational exposure, nutritional status and to diagnose certain diseases. However, sampling and washing protocols for nail analyses vary from study to study not allowing comparisons between studies. One of the difficulties in analyzing nail samples is to eliminate only surface contamination without removing elements of interest in this tissue. In the present study, a protocol was defined in order to obtain reliable results of element concentrations in human nail clippings. Nail clippings collected from all 10 fingers or toes were previously pre cleaned using an ethyl alcohol solution to eliminate microbes. Then, the clippings were cut in small pieces and submitted to different reagents for washing by shaking. Neutron activation analysis (NAA) was applied for nail samples analysis which consisted of irradiating aliquots of samples together with synthetic elemental standards in the IEA-R1 nuclear research reactor followed by gamma ray spectrometry. Comparisons made between the results obtained for nails submitted to different reagents for cleaning indicated that the procedure using acetone and Triton X100 solution is more effective than that of nitric acid solution. Analyses in triplicates of a nail sample indicated results with relative standard deviations lower than 15% for most of elements, showing the homogeneity of the prepared sample. Qualitative analyses of different nail polishes showed that the presence of elements determined in the present study is negligible in these products. Quality control of the analytical results indicated that the applied NAA procedure is adequate for human nail analysis. (author)

  10. Turbo Decision Aided Receivers for Clipping Noise Mitigation in Coded OFDM

    Directory of Open Access Journals (Sweden)

    Declercq David

    2008-01-01

    Full Text Available Abstract Orthogonal frequency division multiplexing (OFDM is the modulation technique used in most of the high-rate communication standards. However, OFDM signals exhibit high peak average to power ratio (PAPR that makes them particularly sensitive to nonlinear distortions caused by high-power amplifiers. Hence, the amplifier needs to operate at large output backoff, thereby decreasing the average efficiency of the transmitter. One way to reduce PAPR consists in clipping the amplitude of the OFDM signal introducing an additional noise that degrades the overall system performance. In that case, the receiver needs to set up an algorithm that compensates this clipping noise. In this paper, we propose three new iterative receivers with growing complexity and performance that operate at severe clipping: the first and simplest receiver uses a Viterbi algorithm as channel decoder whereas the other two implement a soft-input soft-output (SISO decoder. Each soft receiver is analyzed through EXIT charts for different mappings. Finally, the performances of the receivers are simulated on both short time-varying channel and AWGN channel.

  11. Turbo Decision Aided Receivers for Clipping Noise Mitigation in Coded OFDM

    Directory of Open Access Journals (Sweden)

    Maxime Colas

    2008-02-01

    Full Text Available Orthogonal frequency division multiplexing (OFDM is the modulation technique used in most of the high-rate communication standards. However, OFDM signals exhibit high peak average to power ratio (PAPR that makes them particularly sensitive to nonlinear distortions caused by high-power amplifiers. Hence, the amplifier needs to operate at large output backoff, thereby decreasing the average efficiency of the transmitter. One way to reduce PAPR consists in clipping the amplitude of the OFDM signal introducing an additional noise that degrades the overall system performance. In that case, the receiver needs to set up an algorithm that compensates this clipping noise. In this paper, we propose three new iterative receivers with growing complexity and performance that operate at severe clipping: the first and simplest receiver uses a Viterbi algorithm as channel decoder whereas the other two implement a soft-input soft-output (SISO decoder. Each soft receiver is analyzed through EXIT charts for different mappings. Finally, the performances of the receivers are simulated on both short time-varying channel and AWGN channel.

  12. Do medical students watch video clips in eLearning and do these facilitate learning?

    Science.gov (United States)

    Romanov, Kalle; Nevgi, Anne

    2007-06-01

    There is controversial evidence of the impact of individual learning style on students' performance in computer-aided learning. We assessed the association between the use of multimedia materials, such as video clips, and collaborative communication tools with learning outcome among medical students. One hundred and twenty-one third-year medical students attended a course in medical informatics (0.7 credits) consisting of lectures, small group sessions and eLearning material. The eLearning material contained six learning modules with integrated video clips and collaborative learning tools in WebCT. Learning outcome was measured with a course exam. Approximately two-thirds of students (68.6%) viewed two or more videos. Female students were significantly more active video-watchers. No significant associations were found between video-watching and self-test scores or the time used in eLearning. Video-watchers were more active in WebCT; they loaded more pages and more actively participated in discussion forums. Video-watching was associated with a better course grade. Students who watched video clips were more active in using collaborative eLearning tools and achieved higher course grades.

  13. Clinical observation of Artisan iris-clip intraocular lens implantation at stage Ⅰ

    Directory of Open Access Journals (Sweden)

    Qing Zhou

    2014-09-01

    Full Text Available AIM: To observe the clinical efficacy of Artisan iris-clip intraocular lens(IOLimplantation on cataract with a wide range of lens dislocation.METHODS: Twenty-four hospital patients(28 eyesof cataract with lens subluxation by trauma(20 patients, 20 eyesand Marfan's syndrome(4 patients, 8 eyesduring May 2007 to December 2011 were selected. All of them underwent phacoemulsification or an anterior vitrectomy and Artisan iris-clip IOL implantation at stage Ⅰ. Postoperative visual acuity, corneal endothelial cell count, intraocular lens position and postoperative complications were observed. Follow-up time was 6mo.RESULTS:Compared with the preoperative, postoperative best corrected visual acuity improved to varying degrees, visual acuity of 0.1-0.5 was in 20 eyes, 0.5-1.0 in 8 eyes. After followed up 1-6mo, no artificial lens shift, iris inflammation, iris atrophy and corneal decompensation and other complications were observed.CONCLUSION: Cataract surgery with a wide range of lens dislocation is difficult, but as long as surgeons who have a wealth of clinical experience and superb skills, still can carry out phacoemulsification surgery or anterior vitrectomy and Artisan iris-clip IOL implantation and obtain a better outcome.

  14. Level of headaches after surgical aneurysm clipping decreases significantly faster compared to endovascular coiled patients

    Directory of Open Access Journals (Sweden)

    Athanasios K. Petridis

    2017-04-01

    Full Text Available In incidental aneurysms, endovascular treatment can lead to post-procedural headaches. We studied the difference of surgical clipping vs. endovascular coiling in concern to post-procedural headaches in patients with ruptured aneurysms. Sixtyseven patients with aneurysmal subarachnoidal haemorrhage were treated in our department from September 1st 2015 - September 1st 2016. 43 Patients were included in the study and the rest was excluded because of late recovery or highgrade subarachnoid bleedings. Twenty-two were surgical treated and twenty-one were interventionally treated. We compared the post-procedural headaches at the time points of 24 h, 21 days, and 3 months after treatment using the visual analog scale (VAS for pain. After surgical clipping the headache score decreased for 8.8 points in the VAS, whereas the endovascular treated population showed a decrease of headaches of 3.3 points. This difference was highly statistical significant and remained significant even after 3 weeks where the pain score for the surgically treated patients was 0.68 and for the endovascular treated 1.8. After 3 months the pain was less than 1 for both groups with surgically treated patients scoring 0.1 and endovascular treated patients 0.9 (not significant. Clipping is relieving the headaches of patients with aneurysm rupture faster and more effective than endovascular coiling. This effect stays significant for at least 3 weeks and plays a crucial role in stress relieve during the acute and subacute ICU care of such patients.

  15. Effect of hair coat clipping on some physiological changes of dairy bulls

    Directory of Open Access Journals (Sweden)

    Prasanpanich, S.

    2006-03-01

    Full Text Available Some physiological responses of 6 Friesian crossbred (87.5% bull yearling with 2.5 years old, averaging 235 kg. bodyweight were investigated under hot humid conditions. All animals were raised in a house (4 × 15 × 5; w × l × h meters, respectively with concrete floor and were assigned to the Pair Comparison Design according to their weight and age into 2 groups. Animals in group 1 were maintained with their natural hair coat while their counterparts in group 2 were coat clipped fortnightly through a 70-day experimental period. The results indicated that the clipped animals had a significantly (P<0.05 lower sweating rate than did the unclipped ones (102.7±15.48 and 48.3±15.48 g/m2/hour, respectively. However, there were no significant differences in rectal temperature, skin temperature and respiratory rate between the two groups of animals. Further study should be done to clarify the consequences of lower sweating rate in clipped animals under hot humid conditions.

  16. Automatic circuit analysis based on mask information

    International Nuclear Information System (INIS)

    Preas, B.T.; Lindsay, B.W.; Gwyn, C.W.

    1976-01-01

    The Circuit Mask Translator (CMAT) code has been developed which converts integrated circuit mask information into a circuit schematic. Logical operations, pattern recognition, and special functions are used to identify and interconnect diodes, transistors, capacitors, and resistances. The circuit topology provided by the translator is compatible with the input required for a circuit analysis program

  17. Analyzing Behaviour of the Utilization of the Online News Clipping Database: Experience in Suan Sunandha Rajabhat University

    OpenAIRE

    Siriporn Poolsuwan; Kanyarat Bussaban

    2014-01-01

    This research aims to investigate and analyze user’s behaviour towards the utilization of the online news clipping database at Suan Sunandha Rajabhat University, Thailand. Data is gathered from 214 lecturers and 380 undergraduate students by using questionnaires. Findings show that most users knew the online news clipping service from their friends, library’s website and their teachers. The users learned how to use it by themselves and others learned by training of SSRU library. Most users us...

  18. Efficacy of electrocoagulation in sealing the cystic artery and cystic duct occluded with only one absorbable clip during laparoscopic cholecystectomy.

    Science.gov (United States)

    Yang, Chang-Ping; Cao, Jin-Lin; Yang, Ren-Rong; Guo, Hong-Rong; Li, Zhao-Hui; Guo, Hai-Ying; Shao, Yin-Can; Liu, Gui-Bao

    2014-02-01

    Even though laparoscopic cholecystectomy (LC) emerged over 20 years ago, controversies persist with regard to the best method to ligate the cystic duct and artery. We proposed to assess the effectiveness and safety of electrocoagulation to seal the cystic artery and cystic duct after their occlusion with only one absorbable clip. We retrospectively compared the clinical data for 635 patients undergoing LC using electrocoagulation to seal the cystic artery and cystic duct that were occluded with only one absorbable clip (Group 1) and 728 patients undergoing LC using titanium clips (Group 2). In parallel, 30 rabbits randomized into six groups underwent cholecystectomy. After cystic duct ligation with absorbable or titanium clips, the animals were sacrificed 1, 3, or 6 months later, and intraabdominal adhesions were assessed after celiotomy. The mean operative time was significantly shorter (41.6 versus 58.9 minutes, PElectrocoagulation of the cystic artery and cystic duct that were occluded with only one absorbable clip is safe and effective during LC. This approach is associated with shortened operative times and reduced leakage, compared with the standard method using metal clips.

  19. O MONITORAMENTO DE NOTÍCIAS COMO FERRAMENTA PARA A INTELIGÊNCIA COMPETITIVATHE CLIPPING AS TOLL FOR COMPETITIVE INTELLIGENCE

    Directory of Open Access Journals (Sweden)

    Ariane Barbosa Lemos

    2011-07-01

    Full Text Available O artigo apresenta um diagnóstico do serviço de monitoramento de notícias (clipping. No estudo, foram investigados os processos de elaboração desse serviço por uma empresa especializada e sua utilização por parte de organizações dos setores de educação executiva, jurídico e entretenimento. Conclui que tanto a empresa clipadora quanto seus clientes consideram o clipping útil para o processo decisório e o serviço é visto de forma complementar a ação geral de inteligência competitiva das organizações. Palavras-chave inteligência competitiva, monitoramento ambiental, fontes de informação e monitoramento de notícias. Abstract The paper presents a diagnostic study about a clipping service. This study focused the development of the service provided by a specialized firm and its use by organizations operating in the executive education, legal and entertainment areas. It concludes that both the company and your customers consider clipping useful for decision making and the clipping is seen as complementary to general action of competitive intelligence organizations. Keywords competitive intelligence, environmental scanning, information source and clipping.

  20. Development of a new detection device using a glass clip emitting infrared fluorescence for laparoscopic surgery of gastric cancer

    International Nuclear Information System (INIS)

    Inada, Shunko Albano; Mori, Kensaku; Fuchi, Shingo; Hasegawa, Junichi; Misawa, Kazunari; Nakanishi, Hayao

    2015-01-01

    In conventional method, to identify location of the tumor intraperitoneally for extirpation of the gastric cancer, charcoal ink is injected around the primary tumor. However, in the time of laparoscopic operation, it is difficult to estimate specific site of primary tumor. In this study we developed a glass phosphors was realized with Yb 3+ , Nd 3+ doped to Bi 2 O 3 -B 2 O 3 based glasses, which have central emission wavelength of 1020 nm and 100 nm of FWHM. Using this glass phosphor, we developed a fluorescent clip and the laparoscopic fluorescent detection system for clip-derived near-infrared light. To evaluated clinical performance of a fluorescent clip and the laparoscopic detection system, we used resected stomach from the patients. Fluorescent clip was fixed on the gastric mucosa, and an excitation light (wavelength: 808nm) was irradiated from outside of stomach for detection of fluorescent through stomach wall. As a result, fluorescent emission from the clip was successfully detected. These results indicate that the glass fluorescent clip in combination with laparoscopic detection system is a very useful method to identify the exact location of the primary gastric cancer. (paper)

  1. Nanofluidic Transistor Circuits

    Science.gov (United States)

    Chang, Hsueh-Chia; Cheng, Li-Jing; Yan, Yu; Slouka, Zdenek; Senapati, Satyajyoti

    2012-02-01

    Non-equilibrium ion/fluid transport physics across on-chip membranes/nanopores is used to construct rectifying, hysteretic, oscillatory, excitatory and inhibitory nanofluidic elements. Analogs to linear resistors, capacitors, inductors and constant-phase elements were reported earlier (Chang and Yossifon, BMF 2009). Nonlinear rectifier is designed by introducing intra-membrane conductivity gradient and by asymmetric external depletion with a reverse rectification (Yossifon and Chang, PRL, PRE, Europhys Lett 2009-2011). Gating phenomenon is introduced by functionalizing polyelectrolytes whose conformation is field/pH sensitive (Wang, Chang and Zhu, Macromolecules 2010). Surface ion depletion can drive Rubinstein's microvortex instability (Chang, Yossifon and Demekhin, Annual Rev of Fluid Mech, 2012) or Onsager-Wien's water dissociation phenomenon, leading to two distinct overlimiting I-V features. Bipolar membranes exhibit an S-hysteresis due to water dissociation (Cheng and Chang, BMF 2011). Coupling the hysteretic diode with some linear elements result in autonomous ion current oscillations, which undergo classical transitions to chaos. Our integrated nanofluidic circuits are used for molecular sensing, protein separation/concentration, electrospray etc.

  2. Experimental Device for Learning of Logical Circuit Design using Integrated Circuits

    OpenAIRE

    石橋, 孝昭

    2012-01-01

    This paper presents an experimental device for learning of logical circuit design using integrated circuits and breadboards. The experimental device can be made at a low cost and can be used for many subjects such as logical circuits, computer engineering, basic electricity, electrical circuits and electronic circuits. The proposed device is effective to learn the logical circuits than the usual lecture.

  3. Variational integrators for electric circuits

    International Nuclear Information System (INIS)

    Ober-Blöbaum, Sina; Tao, Molei; Cheng, Mulin; Owhadi, Houman; Marsden, Jerrold E.

    2013-01-01

    In this contribution, we develop a variational integrator for the simulation of (stochastic and multiscale) electric circuits. When considering the dynamics of an electric circuit, one is faced with three special situations: 1. The system involves external (control) forcing through external (controlled) voltage sources and resistors. 2. The system is constrained via the Kirchhoff current (KCL) and voltage laws (KVL). 3. The Lagrangian is degenerate. Based on a geometric setting, an appropriate variational formulation is presented to model the circuit from which the equations of motion are derived. A time-discrete variational formulation provides an iteration scheme for the simulation of the electric circuit. Dependent on the discretization, the intrinsic degeneracy of the system can be canceled for the discrete variational scheme. In this way, a variational integrator is constructed that gains several advantages compared to standard integration tools for circuits; in particular, a comparison to BDF methods (which are usually the method of choice for the simulation of electric circuits) shows that even for simple LCR circuits, a better energy behavior and frequency spectrum preservation can be observed using the developed variational integrator

  4. Development of a new biodegradable operative clip made of a magnesium alloy: Evaluation of its safety and tolerability for canine cholecystectomy.

    Science.gov (United States)

    Yoshida, Toshihiko; Fukumoto, Takumi; Urade, Takeshi; Kido, Masahiro; Toyama, Hirochika; Asari, Sadaki; Ajiki, Tetsuo; Ikeo, Naoko; Mukai, Toshiji; Ku, Yonson

    2017-06-01

    Operative clips used to ligate vessels in abdominal operation usually are made of titanium. They remain in the body permanently and form metallic artifacts in computed tomography images, which impair accurate diagnosis. Although biodegradable magnesium instruments have been developed in other fields, the physical properties necessary for operative clips differ from those of other instruments. We developed a biodegradable magnesium-zinc-calcium alloy clip with good biologic compatibility and enough clamping capability as an operative clip. In this study, we verified the safety and tolerability of this clip for use in canine cholecystectomy. Nine female beagles were used. We performed cholecystectomy and ligated the cystic duct by magnesium alloy or titanium clips. The chronologic change of clips and artifact formation were compared at 1, 4, 12, 18, and 24 weeks postoperative by computed tomography. The animals were killed at the end of the observation period, and the clips were removed to evaluate their biodegradability. We also evaluated their effect on the living body by blood biochemistry data. The magnesium alloy clip formed much fewer artifacts than the titanium clip, and it was almost absorbed at 6 months postoperative. There were no postoperative complications and no elevation of constituent elements such as magnesium, calcium, and zinc during the observation period in both groups. The novel magnesium alloy clip demonstrated sufficient sealing capability for the cystic duct and proper biodegradability in canine models. The magnesium alloy clip revealed much fewer metallic artifacts in CT than the conventional titanium clip. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Integrated circuits, and design and manufacture thereof

    Science.gov (United States)

    Auracher, Stefan; Pribbernow, Claus; Hils, Andreas

    2006-04-18

    A representation of a macro for an integrated circuit layout. The representation may define sub-circuit cells of a module. The module may have a predefined functionality. The sub-circuit cells may include at least one reusable circuit cell. The reusable circuit cell may be configured such that when the predefined functionality of the module is not used, the reusable circuit cell is available for re-use.

  6. Ovarian cryopreservation after laparoscopic ovariectomy using the Endo-GIA stapling device and LAPRO-clip absorbable ligating clip in a woman: a case report

    Directory of Open Access Journals (Sweden)

    Messner Alexandra

    2011-02-01

    Full Text Available Abstract Introduction Several options are available for preserving fertility before cytotoxic treatment, including ovarian tissue cryopreservation. Most reported surgical techniques include electrocoagulation. Our hypothesis is that avoidance of electrocoagulation may decrease ovarian cortex injury during cryopreservation procedures. Case presentation We report a laparoscopic technique of whole-ovary removal without coagulation using Endo-GIA forceps and clips. Laparoscopic ovariectomy was performed for cryopreservation in a 37-year-old Caucasian woman with breast cancer and for whom chemotherapy was planned. The procedure was completed quickly and without complication. This Endo-GIA procedure was of short duration with a short period of ischemia before freezing. Conclusion Laparoscopic ovariectomy using the Endo-GIA stapling device procedure without coagulation may diminish ovary injury before ovarian cryopreservation.

  7. Ovarian cryopreservation after laparoscopic ovariectomy using the Endo-GIA stapling device and LAPRO-clip absorbable ligating clip in a woman: a case report

    Science.gov (United States)

    2011-01-01

    Introduction Several options are available for preserving fertility before cytotoxic treatment, including ovarian tissue cryopreservation. Most reported surgical techniques include electrocoagulation. Our hypothesis is that avoidance of electrocoagulation may decrease ovarian cortex injury during cryopreservation procedures. Case presentation We report a laparoscopic technique of whole-ovary removal without coagulation using Endo-GIA forceps and clips. Laparoscopic ovariectomy was performed for cryopreservation in a 37-year-old Caucasian woman with breast cancer and for whom chemotherapy was planned. The procedure was completed quickly and without complication. This Endo-GIA procedure was of short duration with a short period of ischemia before freezing. Conclusion Laparoscopic ovariectomy using the Endo-GIA stapling device procedure without coagulation may diminish ovary injury before ovarian cryopreservation. PMID:21291518

  8. Radiation-sensitive switching circuits

    Energy Technology Data Exchange (ETDEWEB)

    Moore, J.H.; Cockshott, C.P.

    1976-03-16

    A radiation-sensitive switching circuit includes a light emitting diode which from time to time illuminates a photo-transistor, the photo-transistor serving when its output reaches a predetermined value to operate a trigger circuit. In order to allow for aging of the components, the current flow through the diode is increased when the output from the transistor falls below a known level. Conveniently, this is achieved by having a transistor in parallel with the diode, and turning the transistor off when the output from the phototransistor becomes too low. The circuit is designed to control the ignition system in an automobile engine.

  9. The Maplin electronic circuits handbook

    CERN Document Server

    Tooley, Michael

    1990-01-01

    The Maplin Electronic Circuits Handbook provides pertinent data, formula, explanation, practical guidance, theory and practical guidance in the design, testing, and construction of electronic circuits. This book discusses the developments in electronics technology techniques.Organized into 11 chapters, this book begins with an overview of the common types of passive component. This text then provides the reader with sufficient information to make a correct selection of passive components for use in the circuits. Other chapters consider the various types of the most commonly used semiconductor

  10. Secure integrated circuits and systems

    CERN Document Server

    Verbauwhede, Ingrid MR

    2010-01-01

    On any advanced integrated circuit or 'system-on-chip' there is a need for security. In many applications the actual implementation has become the weakest link in security rather than the algorithms or protocols. The purpose of the book is to give the integrated circuits and systems designer an insight into the basics of security and cryptography from the implementation point of view. As a designer of integrated circuits and systems it is important to know both the state-of-the-art attacks as well as the countermeasures. Optimizing for security is different from optimizations for speed, area,

  11. INTEGRATED SENSOR EVALUATION CIRCUIT AND METHOD FOR OPERATING SAID CIRCUIT

    OpenAIRE

    Krüger, Jens; Gausa, Dominik

    2015-01-01

    WO15090426A1 Sensor evaluation device and method for operating said device Integrated sensor evaluation circuit for evaluating a sensor signal (14) received from a sensor (12), having a first connection (28a) for connection to the sensor and a second connection (28b) for connection to the sensor. The integrated sensor evaluation circuit comprises a configuration data memory (16) for storing configuration data which describe signal properties of a plurality of sensor control signals (26a-c). T...

  12. Quantum circuit behaviour

    International Nuclear Information System (INIS)

    Poulton, D.

    1989-09-01

    Single electron tunnelling in multiply connected weak link systems is considered. Using a second quantised approach the tunnel current, in both normal and superconducting systems, using perturbation theory, is derived. The tunnel currents are determined as a function of an Aharanov-Bohm phase (acquired by the electrons). Using these results, the multiply connected system is then discussed when coupled to a resonant LC circuit. The resulting dynamics of this composite system are then determined. In the superconducting case the results are compared and contrasted with flux mode behaviour seen in large superconducting weak link rings. Systems in which the predicted dynamics may be seen are also discussed. In analogy to the electron tunnelling analysis, the tunnelling of magnetic flux quanta through the weak link is also considered. Here, the voltage across the weak link, due to flux tunnelling, is determined as a function of an externally applied current. This is done for both singly and multiply connected flux systems. The results are compared and contrasted with charge mode behaviour seen in superconducting weak link systems. Finally, the behaviour of simple quantum fluids is considered when subject to an external rotation. Using a microscopic analysis it is found that the microscopic quantum behaviour of the particles is manifest on a macroscopic level. Results are derived for bosonic, fermionic and BCS pair-type systems. The connection between flux quantisation in electromagnetic systems is also made. Using these results, the dynamics of such a quantum fluid is considered when coupled to a rotating torsional oscillator. The results are compared with those found in SQUID devices. A model is also presented which discusses the possible excited state dynamics of such a fluid. (author)

  13. Transistor and integrated circuit manufacture

    International Nuclear Information System (INIS)

    Colman, D.

    1978-01-01

    This invention relates to the manufacture of transistors and integrated circuits by ion bombardment techniques and is particularly, but not exclusively, of value in the manufacture of so-called integrated injection logic circuitry. (author)

  14. Time domain analog circuit simulation

    NARCIS (Netherlands)

    Fijnvandraat, J.G.; Houben, S.H.M.J.; Maten, ter E.J.W.; Peters, J.M.F.

    2006-01-01

    Recent developments of new methods for simulating electric circuits are described. Emphasis is put on methods that fit existing datastructures for backward differentiation formulae methods. These methods can be modified to apply to hierarchically organized datastructures, which allows for efficient

  15. Circuit design on plastic foils

    CERN Document Server

    Raiteri, Daniele; Roermund, Arthur H M

    2015-01-01

    This book illustrates a variety of circuit designs on plastic foils and provides all the information needed to undertake successful designs in large-area electronics.  The authors demonstrate architectural, circuit, layout, and device solutions and explain the reasons and the creative process behind each. Readers will learn how to keep under control large-area technologies and achieve robust, reliable circuit designs that can face the challenges imposed by low-cost low-temperature high-throughput manufacturing.   • Discusses implications of problems associated with large-area electronics and compares them to standard silicon; • Provides the basis for understanding physics and modeling of disordered material; • Includes guidelines to quickly setup the basic CAD tools enabling efficient and reliable designs; • Illustrates practical solutions to cope with hard/soft faults, variability, mismatch, aging and bias stress at architecture, circuit, layout, and device levels.

  16. Discharge quenching circuit for counters

    International Nuclear Information System (INIS)

    Karasik, A.S.

    1982-01-01

    A circuit for quenching discharges in gas-discharge detectors with working voltage of 3-5 kV based on transistors operating in the avalanche mode is described. The quenching circuit consists of a coordinating emitter follower, amplifier-shaper for avalanche key cascade control which changes potential on the counter electrodes and a shaper of discharge quenching duration. The emitter follower is assembled according to a widely used flowsheet with two transistors. The circuit permits to obtain a rectangular quenching pulse with front of 100 ns and an amplitude of up to 3.2 kV at duration of 500 μm-8 ms. Application of the quenching circuit described permits to obtain countering characteristics with the slope less than or equal to 0.02%/V and plateau extent greater than or equal to 300 V [ru

  17. Transistor and integrated circuit manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Colman, D

    1978-09-27

    This invention relates to the manufacture of transistors and integrated circuits by ion bombardment techniques and is particularly, but not exclusively, of value in the manufacture of so-called integrated injection logic circuitry.

  18. Ignition circuit for combustion engines

    Energy Technology Data Exchange (ETDEWEB)

    Becker, H W

    1977-05-26

    The invention refers to the ignition circuit for combustion engines, which are battery fed. The circuit contains a transistor and an oscillator to produce an output voltage on the secondary winding of an output transformer to supply an ignition current. The plant is controlled by an interrupter. The purpose of the invention is to form such a circuit that improved sparks for ignition are produced, on the one hand, and that on the other hand, the plant can continue to function after loss of the oscillator. The problem is solved by the battery and the secondary winding of the output transformers of the oscillator are connected via a rectifier circuit to produce a resultant total voltage with the ignition coil from the battery voltage and the rectified pulsating oscillator output.

  19. Clipping treatment of posterior communicating artery aneurysms associated with arteriosclerosis and calcification: A single center study of 136 cases.

    Science.gov (United States)

    Shi, Lei; Yu, Jing; Zhao, Ying; Xu, Kan; Yu, Jinlu

    2018-02-01

    It is widely acknowledged that arteriosclerosis and calcification of the parent artery and aneurysm neck make it difficult to clip posterior communicating artery (PCoA) aneurysms. A total of 136 cases of PCoA aneurysms accompanied by arteriosclerosis and calcification were collected and treated with clipping in the present study. Of the 136 patients, 112 were females (82.4%) and 24 were males (17.6%), with ages ranging from 37 to 76 years (mean age, 60.2 years). Rupture of a PCoA aneurysm was identified in 132 cases (97.1%), and there were 4 cases of unruptured PCoA aneurysms (2.9%). According to the severity of arteriosclerosis and calcification, the aneurysms were divided into type I, II or III. The treatment of type I aneurysms achieved the best curative effect. It is difficult to temporarily occlude type II and III aneurysms during surgery, and temporary occlusion failed in almost 50% of cases. Types II and III were prone to intraoperative aneurysm ruptures. A significantly higher rate of intraoperative aneurysm rupture was seen in type III compared with type II cases. Type II and III cases were more likely to be treated using a fenestrated clip for aneurysm clipping compared with type I cases, and fenestrated clips were used significantly more frequently in type III cases compared with type II cases. Arteriosclerosis and calcification were likely to affect the prognosis of patients, particularly in cases with type III arteriosclerosis and calcification of the parent artery and aneurysm neck. Therefore, the stratification of the arteriosclerosis and calcification of the parent artery and aneurysm neck into types I-III can guide the intraoperative aneurysm clipping strategy, aid in choosing the correct clips, and inform predictions of the occurrence of rupture and hemorrhage, as well as the prognosis for aneurysms.

  20. A Systematic Review and Meta-Analysis on Economic Comparison Between Endovascular Coiling Versus Neurosurgical Clipping for Ruptured Intracranial Aneurysms.

    Science.gov (United States)

    Zhang, Xiaoxi; Li, Li; Hong, Bo; Xu, Yi; Liu, Yuan; Huang, Qinghai; Liu, Jianmin

    2018-05-01

    Healthcare expenditures and cost reduction have been under critical surveillance in all countries and are critical for policymakers. This review aims at qualitatively and quantitatively analyzing the difference of hospital costs and length of stay between endovascular coiling versus neurosurgical clipping in ruptured intracranial aneurysms (RAs). MEDLINE, the Cochrane database, Embase, and the Web of Science database were searched and evaluated independently by 2 authors according to the Newcastle-Ottawa Scale for cohort studies describing economic hospital cost or length of stay in patients with RAs. A total of 8 studies were included, describing 24,219 RAs treated with neurosurgical clipping and 24,962 RAs with endovascular coiling. Meta-analysis revealed that the total hospital costs (THCs) were similar between coiling versus clipping in RAs (standard mean difference [SMD], -0.05; 95% confidence interval [CI], -0.12 to 0.22; I 2  = 99%; P = 0.50). Subgroup analysis showed that THCs of clipping and coiling were similar in ruptured aneurysms in the United States. However, in South Korea, the THCs of coiling were significantly higher than clipping. In the long run, 1-year medical costs of endovascular treatment were significantly lower than that of clipping in RAs (SMD, 0.15; 95% CI, 0.05-0.25; I 2  = 66%; P = 0.005). In addition, the length of stay of coiled patients was significantly shorter than clipped patients (SMD, 0.29; 95% CI, 0.13-0.45; I 2  = 96%; P China, coiling was more expensive. The length of stay was much shorter in coiled patients in all countries. Copyright © 2018. Published by Elsevier Inc.

  1. Epicardial clip occlusion of the left atrial appendage during cardiac surgery provides optimal surgical results and long-term stability.

    Science.gov (United States)

    Kurfirst, Vojtech; Mokrácek, Aleš; Canádyová, Júlia; Frána, Radim; Zeman, Petr

    2017-07-01

    Occlusion of the left atrial appendage (LAA) has become an integral and important part of the surgical treatment of atrial fibrillation. Different methods of surgical occlusion of the LAA have been associated with varying levels of short- and long-term success for closure. The purpose of this study was to evaluate long-term results of epicardial placement and endocardial occlusion in patients undergoing cardiac operative procedures. A total of 101 patients (average age 65.7 years) undergoing cardiac operative procedures with the epicardial AtriClip Exclusion System of the LAA were enrolled in the study. The AtriClip was placed via a sternotomy or a thoracotomy or from a thoracoscopic approach. Postoperative variables, such as thromboembolic events, clip stability and endocardial leakage around the device, were examined by transoesophageal echocardiography (TEE) and/or computed tomography. Perioperative clip implantation was achieved in 98% of patients. TEE and/or computed tomography conducted during the follow-up period, comprising 1873 patient-months with a mean duration of 18 ± 11 months, revealed no clip migration, no leakage around the device and no clot formation near the remnant cul-de-sac. During the follow-up period, 4 of the cardiac patients experienced transitory ischaemic attacks, whereas no patient experienced a cerebrovascular attack. The Epicardial AtriClip Exclusion System of the LAA appears to be a feasable and safe operative method with a high success rate. Long-term follow-up confirmed clip stability, complete occlussion of the LAA and absence of any atrial fibrilation-related thromboembolic events. These results need to be confirmed by a larger, multicentre study. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. A clip domain serine protease involved in moulting in the silkworm, Bombyx mori: cloning, characterization, expression patterns and functional analysis.

    Science.gov (United States)

    Liu, H-W; Wang, L-L; Meng, Z; Tang, X; Li, Y-S; Xia, Q-Y; Zhao, P

    2017-10-01

    Clip domain serine proteases (CLIPs), characterized by one or more conserved clip domains, are essential components of extracellular signalling cascades in various biological processes, especially in innate immunity and the embryonic development of insects. Additionally, CLIPs may have additional non-immune functions in insect development. In the present study, the clip domain serine protease gene Bombyx mori serine protease 95 (BmSP95), which encodes a 527-residue protein, was cloned from the integument of B. mori. Bioinformatics analysis indicated that BmSP95 is a typical CLIP of the subfamily D and possesses a clip domain at the N terminus, a trypsin-like serine protease (tryp_spc) domain at the C terminus and a conserved proline-rich motif between these two domains. At the transcriptional level, BmSP95 is expressed in the integument during moulting and metamorphosis, and the expression pattern is consistent with the fluctuating 20-hydroxyecdysone (20E) titre in B. mori. At the translational level, BmSP95 protein is synthesized in the epidermal cells, secreted as a zymogen and activated in the moulting fluid. Immunofluorescence revealed that BmSP95 is distributed into the old endocuticle in the moulting stage. The expression of BmSP95 was upregulated by 20E. Moreover, expression of BmSP95 was downregulated by pathogen infection. RNA interference-mediated silencing of BmSP95 led to delayed moulting from pupa to moth. These results suggest that BmSP95 is involved in integument remodelling during moulting and metamorphosis. © 2017 The Royal Entomological Society.

  3. Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements

    Directory of Open Access Journals (Sweden)

    Grace Kelly Martins Carneiro

    2015-08-01

    Full Text Available OBJECTIVE: The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip.METHODS: Three types of active/interactive ceramic self-ligating brackets (n = 20 were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000, after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip.RESULTS: The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811. There were significant differences on stiffness among the three types of brackets (p = 0.005. The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle.CONCLUSION: Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation.

  4. Psychophysiological correlates of sexually and non-sexually motivated attention to film clips in a workload task.

    Science.gov (United States)

    Carvalho, Sandra; Leite, Jorge; Galdo-Álvarez, Santiago; Gonçalves, Oscar F

    2011-01-01

    Some authors have speculated that the cognitive component (P3) of the Event-Related Potential (ERP) can function as a psychophysiological measure of sexual interest. The aim of this study was to determine if the P3 ERP component in a workload task can be used as a specific and objective measure of sexual motivation by comparing the neurophysiologic response to stimuli of motivational relevance with different levels of valence and arousal. A total of 30 healthy volunteers watched different films clips with erotic, horror, social-positive and social-negative content, while answering an auditory oddball paradigm. Erotic film clips resulted in larger interference when compared to both the social-positive and auditory alone conditions. Horror film clips resulted in the highest levels of interference with smaller P3 amplitudes than erotic and also than social-positive, social-negative and auditory alone condition. No gender differences were found. Both horror and erotic film clips significantly decreased heart rate (HR) when compared to both social-positive and social-negative films. The erotic film clips significantly increased the skin conductance level (SCL) compared to the social-negative films. The horror film clips significantly increased the SCL compared to both social-positive and social-negative films. Both the highly arousing erotic and non-erotic (horror) movies produced the largest decrease in the P3 amplitude, a decrease in the HR and an increase in the SCL. These data support the notion that this workload task is very sensitive to the attentional resources allocated to the film clip, although they do not act as a specific index of sexual interest. Therefore, the use of this methodology seems to be of questionable utility as a specific measure of sexual interest or as an objective measure of the severity of Hypoactive Sexual Desire Disorder. © 2011 Carvalho et al.

  5. Psychophysiological correlates of sexually and non-sexually motivated attention to film clips in a workload task.

    Directory of Open Access Journals (Sweden)

    Sandra Carvalho

    Full Text Available Some authors have speculated that the cognitive component (P3 of the Event-Related Potential (ERP can function as a psychophysiological measure of sexual interest. The aim of this study was to determine if the P3 ERP component in a workload task can be used as a specific and objective measure of sexual motivation by comparing the neurophysiologic response to stimuli of motivational relevance with different levels of valence and arousal. A total of 30 healthy volunteers watched different films clips with erotic, horror, social-positive and social-negative content, while answering an auditory oddball paradigm. Erotic film clips resulted in larger interference when compared to both the social-positive and auditory alone conditions. Horror film clips resulted in the highest levels of interference with smaller P3 amplitudes than erotic and also than social-positive, social-negative and auditory alone condition. No gender differences were found. Both horror and erotic film clips significantly decreased heart rate (HR when compared to both social-positive and social-negative films. The erotic film clips significantly increased the skin conductance level (SCL compared to the social-negative films. The horror film clips significantly increased the SCL compared to both social-positive and social-negative films. Both the highly arousing erotic and non-erotic (horror movies produced the largest decrease in the P3 amplitude, a decrease in the HR and an increase in the SCL. These data support the notion that this workload task is very sensitive to the attentional resources allocated to the film clip, although they do not act as a specific index of sexual interest. Therefore, the use of this methodology seems to be of questionable utility as a specific measure of sexual interest or as an objective measure of the severity of Hypoactive Sexual Desire Disorder.

  6. Reverse engineering of integrated circuits

    Science.gov (United States)

    Chisholm, Gregory H.; Eckmann, Steven T.; Lain, Christopher M.; Veroff, Robert L.

    2003-01-01

    Software and a method therein to analyze circuits. The software comprises several tools, each of which perform particular functions in the Reverse Engineering process. The analyst, through a standard interface, directs each tool to the portion of the task to which it is most well suited, rendering previously intractable problems solvable. The tools are generally used iteratively to produce a successively more abstract picture of a circuit, about which incomplete a priori knowledge exists.

  7. Virus-Clip: a fast and memory-efficient viral integration site detection tool at single-base resolution with annotation capability.

    Science.gov (United States)

    Ho, Daniel W H; Sze, Karen M F; Ng, Irene O L

    2015-08-28

    Viral integration into the human genome upon infection is an important risk factor for various human malignancies. We developed viral integration site detection tool called Virus-Clip, which makes use of information extracted from soft-clipped sequencing reads to identify exact positions of human and virus breakpoints of integration events. With initial read alignment to virus reference genome and streamlined procedures, Virus-Clip delivers a simple, fast and memory-efficient solution to viral integration site detection. Moreover, it can also automatically annotate the integration events with the corresponding affected human genes. Virus-Clip has been verified using whole-transcriptome sequencing data and its detection was validated to have satisfactory sensitivity and specificity. Marked advancement in performance was detected, compared to existing tools. It is applicable to versatile types of data including whole-genome sequencing, whole-transcriptome sequencing, and targeted sequencing. Virus-Clip is available at http://web.hku.hk/~dwhho/Virus-Clip.zip.

  8. Receiver Gain Modulation Circuit

    Science.gov (United States)

    Jones, Hollis; Racette, Paul; Walker, David; Gu, Dazhen

    2011-01-01

    A receiver gain modulation circuit (RGMC) was developed that modulates the power gain of the output of a radiometer receiver with a test signal. As the radiometer receiver switches between calibration noise references, the test signal is mixed with the calibrated noise and thus produces an ensemble set of measurements from which ensemble statistical analysis can be used to extract statistical information about the test signal. The RGMC is an enabling technology of the ensemble detector. As a key component for achieving ensemble detection and analysis, the RGMC has broad aeronautical and space applications. The RGMC can be used to test and develop new calibration algorithms, for example, to detect gain anomalies, and/or correct for slow drifts that affect climate-quality measurements over an accelerated time scale. A generalized approach to analyzing radiometer system designs yields a mathematical treatment of noise reference measurements in calibration algorithms. By treating the measurements from the different noise references as ensemble samples of the receiver state, i.e. receiver gain, a quantitative description of the non-stationary properties of the underlying receiver fluctuations can be derived. Excellent agreement has been obtained between model calculations and radiometric measurements. The mathematical formulation is equivalent to modulating the gain of a stable receiver with an externally generated signal and is the basis for ensemble detection and analysis (EDA). The concept of generating ensemble data sets using an ensemble detector is similar to the ensemble data sets generated as part of ensemble empirical mode decomposition (EEMD) with exception of a key distinguishing factor. EEMD adds noise to the signal under study whereas EDA mixes the signal with calibrated noise. It is mixing with calibrated noise that permits the measurement of temporal-functional variability of uncertainty in the underlying process. The RGMC permits the evaluation of EDA by

  9. Media Clips.

    Science.gov (United States)

    Lancaster, Ron; Marion, Charlie

    1996-01-01

    Two lessons, 1 dealing with Social Security taxes and the other with the Dow Jones industrial average, are presented along with 10 questions and answers designed to demonstrate to students that mathematics is useful, current, and newsworthy. (AIM)

  10. Clip & Save.

    Science.gov (United States)

    Hubbard, Guy

    2001-01-01

    Provides historical information on the art movement called Cubism that began with two artists, Georges Braque and Pablo Picasso. Discusses possible activities for students and discusses the life of Max Weber. Focuses on Weber's painting, "Rush Hour, New York." (CMK)

  11. Electroencephalography Amplitude Modulation Analysis for Automated Affective Tagging of Music Video Clips

    Directory of Open Access Journals (Sweden)

    Andrea Clerico

    2018-01-01

    Full Text Available The quantity of music content is rapidly increasing and automated affective tagging of music video clips can enable the development of intelligent retrieval, music recommendation, automatic playlist generators, and music browsing interfaces tuned to the users' current desires, preferences, or affective states. To achieve this goal, the field of affective computing has emerged, in particular the development of so-called affective brain-computer interfaces, which measure the user's affective state directly from measured brain waves using non-invasive tools, such as electroencephalography (EEG. Typically, conventional features extracted from the EEG signal have been used, such as frequency subband powers and/or inter-hemispheric power asymmetry indices. More recently, the coupling between EEG and peripheral physiological signals, such as the galvanic skin response (GSR, have also been proposed. Here, we show the importance of EEG amplitude modulations and propose several new features that measure the amplitude-amplitude cross-frequency coupling per EEG electrode, as well as linear and non-linear connections between multiple electrode pairs. When tested on a publicly available dataset of music video clips tagged with subjective affective ratings, support vector classifiers trained on the proposed features were shown to outperform those trained on conventional benchmark EEG features by as much as 6, 20, 8, and 7% for arousal, valence, dominance and liking, respectively. Moreover, fusion of the proposed features with EEG-GSR coupling features showed to be particularly useful for arousal (feature-level fusion and liking (decision-level fusion prediction. Together, these findings show the importance of the proposed features to characterize human affective states during music clip watching.

  12. Initial experience of percutaneous treatment of mitral regurgitation with MitraClip® therapy in Spain.

    Science.gov (United States)

    Carrasco-Chinchilla, Fernando; Arzamendi, Dabit; Romero, Miguel; Gimeno de Carlos, Federico; Alonso-Briales, Juan Horacio; Li, Chi-Hion; Mesa, Maria Dolores; Arnold, Roman; Serrador Frutos, Ana María; Pan, Manuel; Roig, Eulalia; Rodríguez-Bailón, Isabel; de la Fuente Galán, Luis; Hernández, José María; Serra, Antonio; Suárez de Lezo, José

    2014-12-01

    Symptomatic mitral regurgitation has an unfavorable prognosis unless treated by surgery. However, the European registry of valvular heart disease reports that 49% of patients with this condition do not undergo surgery. Percutaneous treatment of mitral regurgitation with MitraClip® has been proved a safe, efficient adjunct to medical treatment in patients with this profile. The objective of the present study is to describe initial experience of MitraClip® therapy in Spain. Retrospective observational study including all patients treated between November 2011 and July 2013 at the 4 Spanish hospitals recording the highest numbers of implantations. A total of 62 patients (77.4% men) were treated, mainly for restrictive functional mitral regurgitation (85.4%) of grade III (37%) or grade IV (63%), mean (standard deviation) ejection fraction 36% (14%), and New York Heart Association functional class III (37%) or IV (63%). Device implantation was successful in 98% of the patients. At 1 year, 81.2% had mitral regurgitation ≤ 2 and 90.9% were in New York Heart Association functional class ≤ II. One periprocedural death occurred (sepsis at 20 days post-implantation) and another 3 patients died during follow-up (mean, 9.1 months). Two patients needed a second implantation due to partial dehiscence of the first device and 2 others underwent heart transplantation. In Spain, MitraClip® therapy has principally been aimed at patients with functional mitral regurgitation, significant systolic ventricular dysfunction, and high surgical risk. It is considered a safe alternative treatment, which can reduce mitral regurgitation and improve functional capacity. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  13. Effects of Mitral Annulus Remodeling Following MitraClip Procedure on Reduction of Functional Mitral Regurgitation.

    Science.gov (United States)

    Hidalgo, Francisco; Mesa, Dolores; Ruiz, Martín; Delgado, Mónica; Rodríguez, Sara; Pardo, Laura; Pan, Manuel; López, Amador; Romero, Miguel A; Suárez de Lezo, José

    2016-11-01

    The percutaneous mitral valve repair procedure (MitraClip) appears to reduce mitral annulus diameter in patients with functional mitral regurgitation, but the relationship between this and regurgitation severity has not been demonstrated. The aim of this study was to determine the effect of mitral annulus remodeling on the reduction of mitral regurgitation in patients with functional etiology. The study included all patients with functional mitral regurgitation treated with MitraClip at our hospital until January 2015. Echocardiogram (iE33 model, Philips) was performed in all patients immediately after device positioning. Changes in the mitral annulus correlated with mitral regurgitation severity, as assessed using the effective regurgitant orifice area. The study included 23 patients (age, 65±14 years; 74% men; left ventricular ejection fraction, 31%±13%; systolic pulmonary artery pressure, 47±10 mmHg). After the procedure, the regurgitant orifice area decreased by 0.30 cm 2 ±0.04 cm 2 (P<.0005), from a baseline of 0.49 cm 2 ±0.09 cm 2 . Anteroposterior diameter decreased by 3.14 mm±1.01 mm (P<.0005) from a baseline of 28.27 mm±4.9 mm, with no changes in the intercommissural diameter (0.50 mm±0.91 mm vs 40.68 mm±4.7 mm; P=.26). A significant association was seen between anteroposterior diameter reduction and regurgitant orifice area reduction (r=.49; P=.020). In patients with functional mitral regurgitation, the MitraClip device produces an immediate reduction in the anteroposterior diameter. This remodeling may be related to the reduction in mitral regurgitation. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  14. Identification of CELF1 RNA targets by CLIP-seq in human HeLa cells

    Directory of Open Access Journals (Sweden)

    Olivier Le Tonquèze

    2016-06-01

    Full Text Available The specific interactions between RNA-binding proteins and their target RNAs are an essential level to control gene expression. By combining ultra-violet cross-linking and immunoprecipitation (CLIP and massive SoliD sequencing we identified the RNAs bound by the RNA-binding protein CELF1, in human HeLa cells. The CELF1 binding sites deduced from the sequence data allow characterizing specific features of CELF1-RNA association. We present therefore the first map of CELF1 binding sites in human cells.

  15. Dual Selectivity Expressed in [2+2+1] Dynamic Clipping of Unsymmetrical [2]Catenanes

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yi

    2010-06-11

    A {pi}-templated dynamic [2+2+1] clipping protocol is established for the synthesis of [2]catenanes from two parts dialdehyde, two parts diamine and one part tetracationic cyclophane. It is further diversified for the selective formation of an unsymmetrical [2]catenane showing great translational selectivity by employing two different dialdehydes in a one-pot reaction. The dual selectivity and the dynamic nature are verified by {sup 1}H NMR spectroscopy, X-ray single crystal structural studies and exchange experiments.

  16. Treatment of Complex Fistula-in-Ano With a Nitinol Proctology Clip

    DEFF Research Database (Denmark)

    Nordholm-Carstensen, Andreas; Krarup, Peter-Martin; Hagen, Kikke

    2017-01-01

    BACKGROUND: The treatment of complex anocutaneous fistulas remains a major therapeutic challenge balancing the risk of incontinence against the chance of permanent closure. OBJECTIVE: The purpose of this study was to investigate the efficacy of a nitinol proctology clip for closure of complex ano...... with those of other noninvasive, sphincter-sparing techniques for high-complex anocutaneous fistulas, with no risk of incontinence. Predictive parameters for fistula healing using this technique remain uncertain. See Video Abstract at http://links.lww.com/DCR/A347....

  17. Pilotless recovery of clipped OFDM signals by compressive sensing over reliable data carriers

    KAUST Repository

    Al-Safadi, Ebrahim B.

    2012-06-01

    In this paper we propose a novel method of clipping mitigation in OFDM using compressive sensing that completely avoids using reserved tones or channel-estimation pilots. The method builds on selecting the most reliable perturbations from the constellation lattice upon decoding at the receiver (in the frequency domain), and performs compressive sensing over these observations in order to completely recover the sparse nonlinear distortion in the time domain. As such, the method provides a practical solution to the problem of initial erroneous decoding decisions in iterative ML methods, and the ability to recover the distorted signal in one shot. © 2012 IEEE.

  18. The Narrative Analysis of the Discourse on Homosexual BDSM Pornograhic Video Clips of The Manhunt Variety

    Directory of Open Access Journals (Sweden)

    Milica Vasić

    2016-02-01

    Full Text Available In this paper we have analyzed the ideal-type model of the story which represents the basic framework of action in Manhunt category pornographic internet video clips, using narrative analysis methods of Claude Bremond. The results have shown that it is possible to apply the theoretical model to elements of visual and mass culture, with certain modifications and taking into account the wider context of the narrative itself. The narrative analysis indicated the significance of researching categories of pornography on the internet, because it leads to a deep analysis of the distribution of power in relations between the categories of heterosexual and homosexual within a virtual environment.

  19. Acute limb ischemia caused by incorrect deployment of a clip-based arterial closure device

    Directory of Open Access Journals (Sweden)

    Łukasz Dzieciuchowicz

    2016-04-01

    Full Text Available Failure of a vascular closure device most commonly results in a hemorrhage or pseudoaneurysm formation. In this paper a rare case of severe acute limb ischemia following incorrect deployment of a clip-based closure device (Starclose SE, Abbott Vascular in a 31-year-old woman is presented. Symptoms of acute limb ischemia occurred at the start of the ambulation, 6 h after completion of the procedure. Because of the severity of ischemia the patient was treated surgically, and limb perfusion was successfully restored. An attempt of closure of an inadvertently punctured narrow superficial femoral artery was identified as the cause of this complication.

  20. Pilotless recovery of clipped OFDM signals by compressive sensing over reliable data carriers

    KAUST Repository

    Al-Safadi, Ebrahim B.; Al-Naffouri, Tareq Y.

    2012-01-01

    In this paper we propose a novel method of clipping mitigation in OFDM using compressive sensing that completely avoids using reserved tones or channel-estimation pilots. The method builds on selecting the most reliable perturbations from the constellation lattice upon decoding at the receiver (in the frequency domain), and performs compressive sensing over these observations in order to completely recover the sparse nonlinear distortion in the time domain. As such, the method provides a practical solution to the problem of initial erroneous decoding decisions in iterative ML methods, and the ability to recover the distorted signal in one shot. © 2012 IEEE.

  1. Top-down and Middle-down Protein Analysis Reveals that Intact and Clipped Human Histones Differ in Post-translational Modification Patterns

    DEFF Research Database (Denmark)

    Tvardovskiy, Andrey; Wrzesinski, Krzysztof; Sidoli, Simone

    2015-01-01

    Post-translational modifications (PTMs) of histone proteins play a fundamental role in regulation of DNA-templated processes. There is also growing evidence that proteolytic cleavage of histone N-terminal tails, known as histone clipping, influences nucleosome dynamics and functional properties...... hepatocytes and the hepatocellular carcinoma cell line HepG2/C3A when grown in spheroid (3D) culture, but not in a flat (2D) culture. Using tandem mass spectrometry we localized four different clipping sites in H3 and one clipping site in H2B. We show that in spheroid culture clipped H3 proteoforms are mainly...

  2. Real-time surgery simulation of intracranial aneurysm clipping with patient-specific geometries and haptic feedback

    Science.gov (United States)

    Fenz, Wolfgang; Dirnberger, Johannes

    2015-03-01

    Providing suitable training for aspiring neurosurgeons is becoming more and more problematic. The increasing popularity of the endovascular treatment of intracranial aneurysms leads to a lack of simple surgical situations for clipping operations, leaving mainly the complex cases, which present even experienced surgeons with a challenge. To alleviate this situation, we have developed a training simulator with haptic interaction allowing trainees to practice virtual clipping surgeries on real patient-specific vessel geometries. By using specialized finite element (FEM) algorithms (fast finite element method, matrix condensation) combined with GPU acceleration, we can achieve the necessary frame rate for smooth real-time interaction with the detailed models needed for a realistic simulation of the vessel wall deformation caused by the clamping with surgical clips. Vessel wall geometries for typical training scenarios were obtained from 3D-reconstructed medical image data, while for the instruments (clipping forceps, various types of clips, suction tubes) we use models provided by manufacturer Aesculap AG. Collisions between vessel and instruments have to be continuously detected and transformed into corresponding boundary conditions and feedback forces, calculated using a contact plane method. After a training, the achieved result can be assessed based on various criteria, including a simulation of the residual blood flow into the aneurysm. Rigid models of the surgical access and surrounding brain tissue, plus coupling a real forceps to the haptic input device further increase the realism of the simulation.

  3. MR liver imaging and cholangiography in the presence of surgical metallic clips at 1.5 and 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Merkle, Elmar M.; Thomas, John; Paulson, Erik K. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States); Dale, Brian M. [Siemens Medical Solutions, Cary, NC (United States)

    2006-10-15

    To evaluate whether clips from prior cholecystectomy impair image quality during magnetic resonance cholangiography (MRC) at 3 Tesla (T) compared with 1.5 T, surgical clips were embedded in a gel phantom and positioned at predefined distances from a fluid-filled tube designed to simulate the bile duct. The maximum clip distance was noted where susceptibility artifacts obscured the fluid-filled tube at 1.5 T and 3 T. Susceptibility artifact size was calculated for each sequence within each magnet class. In vivo analysis included 42 patients postcholecystectomy who underwent MRC at either 1.5 T or 3 T. In vitro, mean area of susceptibility artifacts was 104 mm{sup 2} on 3-T and 75 mm{sup 2} on 1.5-T MR imaging (MRI). While surgical clips within a 2-mm range impaired visualization of the fluid-filled tube on 1.5-T MRI, this range increased to 4 mm on 3-T MRI. In vivo, MRC image quality was impaired by susceptibility artifacts in three of 21 cases at 3 T and in two of 21 cases at 1.5 T. Overall, biliary pseudo-obstructions due to susceptibility artifacts from cholecystectomy surgical clips were not substantially more common on 3-T MRC in clinical practice, and patients with a history of prior cholecystectomy should not be excluded from a 3-T MRC. (orig.)

  4. CLIP-seq analysis of multi-mapped reads discovers novel functional RNA regulatory sites in the human transcriptome.

    Science.gov (United States)

    Zhang, Zijun; Xing, Yi

    2017-09-19

    Crosslinking or RNA immunoprecipitation followed by sequencing (CLIP-seq or RIP-seq) allows transcriptome-wide discovery of RNA regulatory sites. As CLIP-seq/RIP-seq reads are short, existing computational tools focus on uniquely mapped reads, while reads mapped to multiple loci are discarded. We present CLAM (CLIP-seq Analysis of Multi-mapped reads). CLAM uses an expectation-maximization algorithm to assign multi-mapped reads and calls peaks combining uniquely and multi-mapped reads. To demonstrate the utility of CLAM, we applied it to a wide range of public CLIP-seq/RIP-seq datasets involving numerous splicing factors, microRNAs and m6A RNA methylation. CLAM recovered a large number of novel RNA regulatory sites inaccessible by uniquely mapped reads. The functional significance of these sites was demonstrated by consensus motif patterns and association with alternative splicing (splicing factors), transcript abundance (AGO2) and mRNA half-life (m6A). CLAM provides a useful tool to discover novel protein-RNA interactions and RNA modification sites from CLIP-seq and RIP-seq data, and reveals the significant contribution of repetitive elements to the RNA regulatory landscape of the human transcriptome. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  5. Clipping of tumour resection margins allows accurate target volume delineation in head and neck cancer adjuvant radiation therapy

    International Nuclear Information System (INIS)

    Bittermann, Gido; Wiedenmann, Nicole; Bunea, Andrei; Schwarz, Steffen J.; Grosu, Anca-L.; Schmelzeisen, Rainer; Metzger, Marc C.

    2015-01-01

    Background: Accurate tumour bed localisation is a key requirement for adjuvant radiotherapy. A new procedure is described for head and neck cancer treatment that improves tumour bed localisation using titanium clips. Materials and methods: Following complete local excision of the primary tumour, the tumour bed was marked with titanium clips. Preoperative gross target volume (GTV) and postoperative tumour bed were examined and the distances between the centres of gravity were evaluated. Results: 49 patients with squamous cell carcinoma of the oral cavity were prospectively enrolled in this study. All patients underwent tumour resection, neck lymph node dissection and defect reconstruction in one stage. During surgery, 7–49 clips were placed in the resection cavity. Surgical clip insertion was successful in 88% (n = 43). Clip identification and tumour bed delineation was successful in all 43 patients. The overall distance between the centres of gravity of the preoperative tumour extension to the tumour bed was 0.9 cm. A significant relationship between the preoperative tumour extension and the postoperative tumour bed volume could be demonstrated. Conclusion: We demonstrate a precise delineation of the former tumour cavity. Improvements in tumour bed delineation allow an increase of accuracy for adjuvant treatment

  6. Appearance and impact of post-operative intracranial clips and coils on whole-brain CT angiography and perfusion

    International Nuclear Information System (INIS)

    Roach, Cayce J.; Russell, Cheryl L.; Hanson, Eric H.; Bluett, Brent; Orrison, William W.

    2012-01-01

    Background: To evaluate the effect of vascular clips and endovascular coils placed for intracranial aneurysms and arteriovenous malformations on whole-brain computed tomography (CT) angiography and perfusion. Methods: A 320-detector row dynamic volume CT system imaged 11 patients following surgical placement of vascular clips or endovascular coils. The extent of clip and coil subtraction by automated software was evaluated using CT digital subtraction angiography and CT perfusion. Impact on CT perfusion values by retained intracranial devices was compared to age- and gender-matched controls. Results: Clip and coil subtraction on CT angiography was graded as good in 8 and moderate in 3 cases. A residual neck and additional aneurysm were noted in 1 of 11 patients. Post-procedural axial slice level CT perfusion values decreased in reliability with increasing proximity to the metallic devices secondary to beam hardening. However, the intracranial devices did not affect axial slice level CTP values of cerebral blood volume, cerebral blood flow and mean transit time outside of the level of the device. Time to peak values was globally decreased outside of the immediate vascular intervention region. Conclusions: Advances in CT technology have provided clinically useful subtraction of intracranial clips and coils. While CT perfusion values were altered in device subtraction areas and within beam hardening artifact areas; they can provide valuable postoperative information on whole-brain hemodynamics. In selected cases, the combination of CT angiography and whole-brain CT perfusion can offer an alternative to conventional angiography that is a more invasive option.

  7. Endoscopic removal of over-the-scope clips using a novel cutting device: a retrospective case series.

    Science.gov (United States)

    Schmidt, Arthur; Riecken, Bettina; Damm, Michael; Cahyadi, Oscar; Bauder, Markus; Caca, Karel

    2014-09-01

    Over-the-scope clips (OTSCs; Ovesco Endoscopy, Tübingen, Germany) are extensively used for treatment of gastrointestinal perforations, leakages, fistulas, and bleeding. In this report, a new method of removing OTSCs using a prototype bipolar cutting device is described. A total of 11 patients underwent endoscopic removal of an OTSC. The OTSC was cut at two opposing sites by a prototype device (DC ClipCutter; Ovesco Endoscopy). The remaining clip fragments were extracted using a standard forceps. Mean procedure time was 47 minutes (range 35 - 75 minutes). Cutting of the OTSC at two opposing sites was successful in all cases (100 %). Complete retrieval of all clip fragments was possible in 10 patients (91 %). The overall success rate for cutting and complete removal of the clip was 91 %. No major complications were observed. Removal of OTSCs with the prototype device was feasible and effective. The device may be valuable for OTSC removal in emergency as well as elective indications. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Spectral Purity Enhancement via Polyphase Multipath Circuits

    NARCIS (Netherlands)

    Mensink, E.; Klumperink, Eric A.M.; Nauta, Bram

    2004-01-01

    The central question of this paper is: can we enhance the spectral purity of nonlinear circuits by using polyphase multipath circuits? The basic idea behind polyphase multipath circuits is to split the nonlinear circuits into two or more paths and exploit phase differences between these paths to

  9. Distortion Cancellation via Polyphase Multipath Circuits

    NARCIS (Netherlands)

    Mensink, E.; Klumperink, Eric A.M.; Nauta, Bram

    The central question of this paper is: can we enhance the spectral purity of nonlinear circuits with the help of polyphase multipath circuits. Polyphase multipath circuits are circuits with two or more paths that exploit phase differences between the paths to cancel unwanted signals. It turns out

  10. Dynamic theory for the mesoscopic electric circuit

    International Nuclear Information System (INIS)

    Chen Bin; Shen Xiaojuan; Li Youquan; Sun LiLy; Yin Zhujian

    2005-01-01

    The quantum theory for mesoscopic electric circuit with charge discreteness is briefly described. The minibands of quasienergy in LC design mesoscopic electric circuit have been found. In the mesoscopic 'pure' inductance design circuit, just like in the mesoscopic metallic rings, the quantum dynamic characteristics have been obtained explicitly. In the 'pure' capacity design circuit, the Coulomb blockade had also been addressed

  11. Multi-Layer E-Textile Circuits

    Science.gov (United States)

    Dunne, Lucy E.; Bibeau, Kaila; Mulligan, Lucie; Frith, Ashton; Simon, Cory

    2012-01-01

    Stitched e-textile circuits facilitate wearable, flexible, comfortable wearable technology. However, while stitched methods of e-textile circuits are common, multi-layer circuit creation remains a challenge. Here, we present methods of stitched multi-layer circuit creation using accessible tools and techniques.

  12. Instrumentation and test gear circuits manual

    CERN Document Server

    Marston, R M

    2013-01-01

    Instrumentation and Test Gear Circuits Manual provides diagrams, graphs, tables, and discussions of several types of practical circuits. The practical circuits covered in this book include attenuators, bridges, scope trace doublers, timebases, and digital frequency meters. Chapter 1 discusses the basic instrumentation and test gear principles. Chapter 2 deals with the design of passive attenuators, and Chapter 3 with passive and active filter circuits. The subsequent chapters tackle 'bridge' circuits, analogue and digital metering techniques and circuitry, signal and waveform generation, and p

  13. Logic circuits from zero forcing.

    Science.gov (United States)

    Burgarth, Daniel; Giovannetti, Vittorio; Hogben, Leslie; Severini, Simone; Young, Michael

    We design logic circuits based on the notion of zero forcing on graphs; each gate of the circuits is a gadget in which zero forcing is performed. We show that such circuits can evaluate every monotone Boolean function. By using two vertices to encode each logical bit, we obtain universal computation. We also highlight a phenomenon of "back forcing" as a property of each function. Such a phenomenon occurs in a circuit when the input of gates which have been already used at a given time step is further modified by a computation actually performed at a later stage. Finally, we show that zero forcing can be also used to implement reversible computation. The model introduced here provides a potentially new tool in the analysis of Boolean functions, with particular attention to monotonicity. Moreover, in the light of applications of zero forcing in quantum mechanics, the link with Boolean functions may suggest a new directions in quantum control theory and in the study of engineered quantum spin systems. It is an open technical problem to verify whether there is a link between zero forcing and computation with contact circuits.

  14. Installations having pressurised fluid circuits

    International Nuclear Information System (INIS)

    Rigg, S.; Grant, J.

    1977-01-01

    Reference is made to nuclear installations having pressurised coolant flow circuits. Breaches in such circuits may quickly result in much damage to the plant. Devices such as non-return valves, orifice plates, and automatically operated shut-off valves have been provided to prevent or reduce fluid flow through a breached pipe line, but such devices have several disadvantages; they may present large restrictions to normal flow of coolant, and may depend on the operation of ancillary equipment, with consequent delay in bringing them into operation in an emergency. Other expedients that have been adopted to prevent or reduce reverse flow through an upstream breach comprise various forms of hydraulic counter flow brakes. The arrangement described has at least one variable fluid brake comprising a fluidic device connected into a duct in the pressurised circuit, the device having an inlet, an outlet, a vortex chamber between the inlet and outlet, a control jet for introducing fluid into the vortex chamber, connections communicating the inlet and the outlet into one part of the circuit and the control jet into another region at a complementary pressure so that, in the event of a breach in the circuit in one region, fluid passes from the other region to enter the vortex chamber to stimulate pressure to create a flow restricting vortex in the chamber that reduces flow through the breach. The system finds particular application to stream generating pressure tube reactors, such as the steam generating heavy water reactor at UKAEA, Winfrith. (U.K.)

  15. 30 CFR 75.601-1 - Short circuit protection; ratings and settings of circuit breakers.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Short circuit protection; ratings and settings... Trailing Cables § 75.601-1 Short circuit protection; ratings and settings of circuit breakers. Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the...

  16. 30 CFR 77.506 - Electric equipment and circuits; overload and short-circuit protection.

    Science.gov (United States)

    2010-07-01

    ... short-circuit protection. 77.506 Section 77.506 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... circuits; overload and short-circuit protection. Automatic circuit-breaking devices or fuses of the correct type and capacity shall be installed so as to protect all electric equipment and circuits against short...

  17. 30 CFR 75.518 - Electric equipment and circuits; overload and short circuit protection.

    Science.gov (United States)

    2010-07-01

    ... short circuit protection. 75.518 Section 75.518 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... Equipment-General § 75.518 Electric equipment and circuits; overload and short circuit protection... installed so as to protect all electric equipment and circuits against short circuit and overloads. Three...

  18. Elevated intracranial pressure and reversible eye-tracking changes detected while viewing a film clip.

    Science.gov (United States)

    Kolecki, Radek; Dammavalam, Vikalpa; Bin Zahid, Abdullah; Hubbard, Molly; Choudhry, Osamah; Reyes, Marleen; Han, ByoungJun; Wang, Tom; Papas, Paraskevi Vivian; Adem, Aylin; North, Emily; Gilbertson, David T; Kondziolka, Douglas; Huang, Jason H; Huang, Paul P; Samadani, Uzma

    2018-03-01

    OBJECTIVE The precise threshold differentiating normal and elevated intracranial pressure (ICP) is variable among individuals. In the context of several pathophysiological conditions, elevated ICP leads to abnormalities in global cerebral functioning and impacts the function of cranial nerves (CNs), either or both of which may contribute to ocular dysmotility. The purpose of this study was to assess the impact of elevated ICP on eye-tracking performed while patients were watching a short film clip. METHODS Awake patients requiring placement of an ICP monitor for clinical purposes underwent eye tracking while watching a 220-second continuously playing video moving around the perimeter of a viewing monitor. Pupil position was recorded at 500 Hz and metrics associated with each eye individually and both eyes together were calculated. Linear regression with generalized estimating equations was performed to test the association of eye-tracking metrics with changes in ICP. RESULTS Eye tracking was performed at ICP levels ranging from -3 to 30 mm Hg in 23 patients (12 women, 11 men, mean age 46.8 years) on 55 separate occasions. Eye-tracking measures correlating with CN function linearly decreased with increasing ICP (p short film clip. These results suggest that eye tracking may be used as a noninvasive, automatable means to quantitate the physiological impact of elevated ICP, which has clinical application for assessment of shunt malfunction, pseudotumor cerebri, concussion, and prevention of second-impact syndrome.

  19. Transcatheter treatment of severe tricuspid regurgitation with the MitraClip system.

    Science.gov (United States)

    Hammerstingl, Christoph; Schueler, Robert; Malasa, Margarita; Werner, Nikos; Nickenig, Georg

    2016-03-07

    The aim of this study was to show technical principles and feasibility of transcatheter tricuspid valve repair by use of the MitraClip system. Three consecutive patients were treated successfully for severe symptomatic Tricuspid regurgitation. Three-dimensional transoesophageal echocardiography confirmed reduction of measured effective regurgitant orifice in all patients [effective regurgitant orifice area-baseline/post-procedure (cm(2)): 0.7/0.3; 1.5/0.8; 0.4/0.1], which was accompanied by an increase in left ventricular stroke volumes [baseline/post-procedure (mL): 42.8/45.4; 38/45; 35.2/45], decrease of measured levels of N terminal pro brain natriuretic peptide (pg/mL: baseline/post-procedure: 548/440; 2526/1702; 1754/623), and significant relief of clinical symptoms for chronic right heart failure in all patients. Transcatheter tricuspid valve repair by use of interventional edge-to-edge repair with the MitraClip system was feasible, and safe in three consecutive patients. Reduction of tricuspid insufficiency associates with relief of clinical symptoms for right heart failure. This strategy seems a promising treatment option for patients at prohibitive surgical risk. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  20. [Surgical fixation of rib fractures with clips and titanium bars (STRATOS System). Preliminary experience].

    Science.gov (United States)

    Moreno De La Santa Barajas, Pablo; Polo Otero, María Dolores; Delgado Sánchez-Gracián, Carlos; Lozano Gómez, Manuel; Toscano Novella, Alberto; Calatayud Moscoso Del Prado, Julia; Leal Ruiloba, Sonsoles; Choren Durán, Maria L

    2010-09-01

    Rib fractures are very common in closed chest injuries. The majority of these patients suffer significant pain with movement and cough. The purpose of this study is to assess the usefulness of titanium rib bars and clips in stabilising rib fractures. Twenty-two patients with rib fractures were treated with open reduction and internal fixation between 2008 and 2009. Indications for treatment were defined as; 1) Patients with unstable chest (13 patients), 2) Patients with pain or instability due to rib fractures (6 patients), and 3) Significant traumatic deformities of the chest wall (3 patients). Age, traumatic mechanism, chest and associated injuries, surgical data, complications and follow-up were prospectively analysed. The surgical technique is described. The majority of patients were extubated immediately after surgery. All patients with pain or instability showed a subjective improvement or disappearance of pain after the surgery. Four patients had a wound infection which had to be drained. After 3 months, 55% of the patients had returned to work or normal life. The results in each group are described. Open reduction with internal fixation of rib fractures is a good alternative. The use of titanium rib bars and clips give good clinical results, are easy to apply and have few complications. Copyright © 2010 AEC. Published by Elsevier Espana. All rights reserved.

  1. Enhanced subcarrier-index modulation-based asymmetrically clipped optical OFDM using even subcarriers

    Science.gov (United States)

    Guan, Rui; Xu, Wei; Yang, Zhaohui; Huang, Nuo; Wang, Jin-Yuan; Chen, Ming

    2017-11-01

    In this paper, we propose a subcarrier-index modulation-based asymmetrically clipped optical orthogonal frequency division multiplexing (SACO-OFDM) scheme for optical wireless communication (OWC) systems, which benefits from the subcarrier-index modulation (SIM) and asymmetrically clipped optical orthogonal frequency division multiplexing (ACO-OFDM) techniques. SACO-OFDM conveys additional information via the subcarrier indexing, and the error rate of the bit transmitted by the subcarrier indexing is much lower than that of the conventional M-ary modulation scheme. On the other hand, as the signal constellation in M-ary modulation is relieved, SACO-OFDM has simple transceiver structure and low detection complexity. Moreover, considering the spectral, an enhanced SACO-OFDM (ESACO-OFDM) using even subcarriers is proposed. In this technique, the odd subcarriers are activated for SACO-OFDM, and the imaginary part of even subcarriers are activated for pulse-amplitude-modulated discrete multitone (PAM-DMT). Clearly, ESACO-OFDM achieves better spectral efficiency than the conventional optical OFDM, since all subcarriers are used for data transmission. Simulation results verify the significant bit error rate (BER) and peak-to-average power ratio (PAPR) improvement by the proposed ESACO-OFDM, especially for the medium-to-high signal-to-noise ratio (SNR) regime.

  2. Integration of object-oriented knowledge representation with the CLIPS rule based system

    Science.gov (United States)

    Logie, David S.; Kamil, Hasan

    1990-01-01

    The paper describes a portion of the work aimed at developing an integrated, knowledge based environment for the development of engineering-oriented applications. An Object Representation Language (ORL) was implemented in C++ which is used to build and modify an object-oriented knowledge base. The ORL was designed in such a way so as to be easily integrated with other representation schemes that could effectively reason with the object base. Specifically, the integration of the ORL with the rule based system C Language Production Systems (CLIPS), developed at the NASA Johnson Space Center, will be discussed. The object-oriented knowledge representation provides a natural means of representing problem data as a collection of related objects. Objects are comprised of descriptive properties and interrelationships. The object-oriented model promotes efficient handling of the problem data by allowing knowledge to be encapsulated in objects. Data is inherited through an object network via the relationship links. Together, the two schemes complement each other in that the object-oriented approach efficiently handles problem data while the rule based knowledge is used to simulate the reasoning process. Alone, the object based knowledge is little more than an object-oriented data storage scheme; however, the CLIPS inference engine adds the mechanism to directly and automatically reason with that knowledge. In this hybrid scheme, the expert system dynamically queries for data and can modify the object base with complete access to all the functionality of the ORL from rules.

  3. Evaluation of Clipping Based Iterative PAPR Reduction Techniques for FBMC Systems

    Directory of Open Access Journals (Sweden)

    Zsolt Kollár

    2014-01-01

    to conventional orthogonal frequency division multiplexing (OFDM technique. The low ACLR of the transmitted FBMC signal makes it especially favorable in cognitive radio applications, where strict requirements are posed on out-of-band radiation. Large dynamic range resulting in high peak-to-average power ratio (PAPR is characteristic of all sorts of multicarrier signals. The advantageous spectral properties of the high-PAPR FBMC signal are significantly degraded if nonlinearities are present in the transceiver chain. Spectral regrowth may appear, causing harmful interference in the neighboring frequency bands. This paper presents novel clipping based PAPR reduction techniques, evaluated and compared by simulations and measurements, with an emphasis on spectral aspects. The paper gives an overall comparison of PAPR reduction techniques, focusing on the reduction of the dynamic range of FBMC signals without increasing out-of-band radiation. An overview is presented on transmitter oriented techniques employing baseband clipping, which can maintain the system performance with a desired bit error rate (BER.

  4. Comparisons of spectrally-enhanced asymmetrically-clipped optical OFDM systems.

    Science.gov (United States)

    Lowery, Arthur James

    2016-02-22

    Asymmetrically clipped optical orthogonal frequency-division multiplexing (ACO-OFDM) is a technique that sacrifices spectral efficiency in order to transmit an orthogonally frequency-division multiplexed signal over a unipolar channel, such as a directly modulated direct-detection fiber or free-space channel. Several methods have been proposed to regain this spectral efficiency, including: asymmetrically clipped DC-biased optical OFDM (ADO-OFDM), enhanced U-OFDM (EU-OFDM), spectral and energy efficient OFDM (SEE-OFDM), Hybrid-ACO-OFDM and Layered-ACO-OFDM. This paper presents simulations up to high-order constellation sizes to show that Layered-ACO-OFDM offers the highest receiver sensitivity for a given optical power at spectral efficiencies above 3 bit/s/Hz. For comparison purposes, white Gaussian noise is added at the receiver, component nonlinearities are not considered, and the fiber is considered to be linear and dispersion-less. The simulations show that LACO-OFDM has a 7-dB sensitivity advantage over DC-biased OFDM (DCO-OFDM) for 1024-QAM at 87.5% of DCO-OFDM's spectral efficiency, at the same bit rate and optical power. This is approximately equivalent to a 4.4-dB advantage at the same spectral efficiency of 87.7% if 896-QAM were to be used for DCO-OFDM.

  5. Right ventricular pressure elevated in one-kidney, one clip Goldblatt hypertensive rats.

    Science.gov (United States)

    Ketabchi, Farzaneh; Bajoovand, Shirin; Adlband, Mojtaba; Naseh, Maryam; Nekooeian, Ali A; Mashghoolozekr, Elaheh

    2017-01-01

    Both renal and respiratory diseases are common with high mortality rate around the world. This study was the first to compare effects of two kidneys, one clip (2K1C) and one-kidney, one clip (1K1C) Goldblatt hypertension on right ventricular pressure during normal condition and mechanical ventilation with hypoxia gas. Male Sprague-Dawley rats were subjected to control, 2K1C, or 1K1C groups. Twenty-eight days after the first surgery, animals were anesthetized, and femoral artery and vein, and right ventricle cannulated. Systemic arterial pressure and right ventricular systolic pressures (RVSP) were recorded during ventilation the animals with normoxic or hypoxic gas. RVSP in the 1K1C group was significantly more than the control and 2K1C groups during baseline conditions and ventilation the animals with hypoxic gas. Administration of antioxidant Trolox increased RVSP in the 1K1C and control groups compared with their baselines. Furthermore, there was no alteration in RVSP during hypoxia in the presence of Trolox. This study indicated that RVSP only increased after 28 days induction of 1K1C but not 2K1C model. In addition, it seems that the response to hypoxic gas and antioxidants in 1K1C is more than 2K1C. These data also suggest that effects of 1K1C may partially be related to reactive oxygen species (ROS) pathways.

  6. First- and third-party ground truth for key frame extraction from consumer video clips

    Science.gov (United States)

    Costello, Kathleen; Luo, Jiebo

    2007-02-01

    Extracting key frames (KF) from video is of great interest in many applications, such as video summary, video organization, video compression, and prints from video. KF extraction is not a new problem. However, current literature has been focused mainly on sports or news video. In the consumer video space, the biggest challenges for key frame selection from consumer videos are the unconstrained content and lack of any preimposed structure. In this study, we conduct ground truth collection of key frames from video clips taken by digital cameras (as opposed to camcorders) using both first- and third-party judges. The goals of this study are: (1) to create a reference database of video clips reasonably representative of the consumer video space; (2) to identify associated key frames by which automated algorithms can be compared and judged for effectiveness; and (3) to uncover the criteria used by both first- and thirdparty human judges so these criteria can influence algorithm design. The findings from these ground truths will be discussed.

  7. Retrieval of Surgical Clip from Common Bile Duct by Endoscopic Retrograde Cholangiopancreatography: A Rare Complication of Laparoscopic Cholecystectomy

    Directory of Open Access Journals (Sweden)

    Shahid Rasool

    2017-04-01

    Full Text Available Laparoscopic cholecystectomy has become the standard procedure for the surgical management of symptomatic cholelithiasis. Laparoscopic cholecystectomy is generally considered a safe procedure although a few complications such as major bleeding, wound infection, bile leakage, biliary and bowel injury are well known. We are reporting a case of a thirty-seven year old male who presented with abdominal pain, three weeks after laparoscopic cholecystectomy. Abdominal ultrasound revealed a filling defect in common bile duct with deranged liver function tests. With an impression of choledocholithiasis, his endoscopic retrograde cholangiopancreatography (ERCP was done which revealed a surgical clip impacted in the ampulla. The surgical clip was retrieved successfully by ERCP. Intraductal clip migration is a rarely encountered complication after laparoscopic cholecystectomy. Appropriate management requires timely identification and retrieval during ERCP.

  8. [Ligation of the retrobulbar vascular-nervous bunch during performance of evisceration and enucleation using titanic clips in ophthalmic surgery].

    Science.gov (United States)

    Rykov, S A; Torchinskaia, N V; Bakbardina, I I; Simchuk, I V

    2011-10-01

    The efficacy of hemostasis achievement during conduction of a retrobulbar vascular-nervous bunch ligation (RVNBL), using titanic clips while evisceroenucleation performance, was studied up. A comparative analysis of clinical and functional results of surgical treatment of 36 patients, suffering terminal dolorous glaucoma and disaster of a sympathetic ophthalmia complication after an eye penetrating wounding occurrence. In 16 patients (the first group) a standard method of a hemostasis achievement was used while doing evisceroenucleation - a deep orbital tamponade for 5 minutes. In 20 patients (the second group) a procedure of RVNBL was conducted, using titanic clips before the bunch transsection doing. There was established, that while doing a RVNPL using titanic clips, a hemorrhage never occurs, a retrobulbar hematoma do not formated, the soft tissues reaction in the early postoperative period is less pronounced, and the patients postoperative rehabilitation period shortens.

  9. Effect of mental challenge induced by movie clips on action potential duration in normal human subjects independent of heart rate.

    Science.gov (United States)

    Child, Nicholas; Hanson, Ben; Bishop, Martin; Rinaldi, Christopher A; Bostock, Julian; Western, David; Cooklin, Michael; O'Neil, Mark; Wright, Matthew; Razavi, Reza; Gill, Jaswinder; Taggart, Peter

    2014-06-01

    Mental stress and emotion have long been associated with ventricular arrhythmias and sudden death in animal models and humans. The effect of mental challenge on ventricular action potential duration (APD) in conscious healthy humans has not been reported. Activation recovery intervals measured from unipolar electrograms as a surrogate for APD (n=19) were recorded from right and left ventricular endocardium during steady-state pacing, whilst subjects watched an emotionally charged film clip. To assess the possible modulating role of altered respiration on APD, the subjects then repeated the same breathing pattern they had during the stress, but without the movie clip. Hemodynamic parameters (mean, systolic, and diastolic blood pressure, and rate of pressure increase) and respiration rate increased during the stressful part of the film clip (P=0.001). APD decreased during the stressful parts of the film clip, for example, for global right ventricular activation recovery interval at end of film clip 193.8 ms (SD, 14) versus 198.0 ms (SD, 13) during the matched breathing control (end film left ventricle 199.8 ms [SD, 16] versus control 201.6 ms [SD, 15]; P=0.004). Respiration rate increased during the stressful part of the film clip (by 2 breaths per minute) and was well matched in the respective control period without any hemodynamic or activation recovery interval changes. Our results document for the first time direct recordings of the effect of a mental challenge protocol on ventricular APD in conscious humans. The effect of mental challenge on APD was not secondary to emotionally induced altered respiration or heart rate. © 2014 American Heart Association, Inc.

  10. SU-E-J-64: Feasibility Study of Surgical Clips for Fiducial Tracking in CyberKnife System

    International Nuclear Information System (INIS)

    Lee, H; Yoon, J; Lee, E; Cho, S; Park, K; Choi, W; Baek, J; Keum, K; Koom, W

    2015-01-01

    Purpose: To investigate the ability of CyberKnife to track surgical clips used as fiducial markers. Methods: The Octavius 1000SRS detector and solid water (RW3) slab phantom were used with motion platform to evaluate the study. The RW3 slab phantom was set up to measure the dose distribution from coronal plane. It consists of 9 plates and the thickness of each plate is 10mm. Among them, one plate was attached with 3 surgical clips, which are orthogonally positioned on outer region of array. The length of attached clip was represented as 1cm on planning CT. The clip plate was placed on the 1000SRS detector and 3 slabs were stacked up on the plate to build the measuring depth. Below the detector, 5 slabs were set. The two-axis motion platform was programmed with 1D sinusoidal movement (20mm peak-to-peak, 3s period) toward superior/inferior and left/right directions to simulate target motion. During delivery, two clips were extracted by two X-ray imagers, which led to translational error correction only. Synchrony was also used for dynamic tracking. After the irradiation, the measured dose distribution of coronal plane was compared with the planar dose distribution calculated by the CyberKnife treatment planning system (Multiplan) for cross verification. The results were assessed by comparing the absolute Gamma (γ) index. Results: The dose distributions measured by the 1000SRS detector were in good agreements with those calculated by Multiplan. In the dosimetric comparison using γ-function criteria based on the distance-to-agreement of 3mm and the local dose difference of 3%, the passing rate with γ- parameter ≤1 was 91% in coronal plane. Conclusion: The surgical clips can be considered as new fiducials for robotic radiosurgery delivery by considering the target margin with less than 5mm

  11. Multiplication circuit for particle identification

    International Nuclear Information System (INIS)

    Gerlier, Jean

    1962-01-01

    After having commented some characteristics of the particles present in a cyclotron, and their interactions, this report addresses the development and the implementation of a method and a device for selecting and counting particles. The author presents the principle and existing techniques of selection. In comparison with an existing device, the proportional counter and the scintillator are replaced by junctions: a surface barrier type junction (a silicon N layer with a very thin oxygen layer playing the role of the P layer), and lithium-based junction (a silicon P type layer made intrinsic by migration of lithium). The author then describes the developed circuit and assembly (background of the choice of a multiplication circuit), and their operation. In the next part, he presents the performed tests and discuses the obtained results. He finally outlines the benefits of the herein presented circuit [fr

  12. Wiring of electronic evaluation circuits

    International Nuclear Information System (INIS)

    Bauer, R.; Svoboda, Z.

    1977-01-01

    The wiring is described of electronic evaluation circuits for the automatic viewing of photographic paper strip negatives on which line tracks with an angular scatter relative to the spectrograph longitudinal axis were recorded during the oblique flight of nuclear particles during exposure in the spectrograph. In coincidence evaluation, the size of the angular scatter eventually requires that evaluation dead time be increased. The equipment consists of minimally two fixed registers and a block of logic circuits whose output is designed such as will allow connection to equipment for recording signals corresponding to the number of tracks on the film. The connection may be implemented using integrated circuits guaranteeing high operating reliability and life. (J.B.)

  13. Counterpulse railgun energy recovery circuit

    International Nuclear Information System (INIS)

    Honig, E.M.

    1986-01-01

    This patent describes a counterpulse railgun energy recovery circuit for propelling a projectile along a railgun the counterpulse railgun energy recovery circuit consists of: a railgun having an effective inductance; a source inductor initially charged to an initial current; current means for initially charging the source inductor to the initial current; first current-zero type switching means; second current-zero type switching; third current-zero type switching; muzzle current-zero type switching means; transfer capacitor, the transfer capacitor is for cooperating with the first, second, third, and muzzle current-zero type switching means for providing a resonant circuit for transferring current from the source inductor to the effective inductance of the railgun during the propelling of a projectile along the railgun and for returning current from the effective inductance of the railgun to the source inductance after the projectile has exited the railgun

  14. Vertically Integrated Circuits at Fermilab

    International Nuclear Information System (INIS)

    Deptuch, Grzegorz; Demarteau, Marcel; Hoff, James; Lipton, Ronald; Shenai, Alpana; Trimpl, Marcel; Yarema, Raymond; Zimmerman, Tom

    2009-01-01

    The exploration of the vertically integrated circuits, also commonly known as 3D-IC technology, for applications in radiation detection started at Fermilab in 2006. This paper examines the opportunities that vertical integration offers by looking at various 3D designs that have been completed by Fermilab. The emphasis is on opportunities that are presented by through silicon vias (TSV), wafer and circuit thinning and finally fusion bonding techniques to replace conventional bump bonding. Early work by Fermilab has led to an international consortium for the development of 3D-IC circuits for High Energy Physics. The consortium has submitted over 25 different designs for the Fermilab organized MPW run organized for the first time.

  15. The source parameters of 2013 Mw6.6 Lushan earthquake constrained with the restored local clipped seismic waveforms

    Science.gov (United States)

    Hao, J.; Zhang, J. H.; Yao, Z. X.

    2017-12-01

    We developed a method to restore the clipped seismic waveforms near epicenter using projection onto convex sets method (Zhang et al, 2016). This method was applied to rescue the local clipped waveforms of 2013 Mw 6.6 Lushan earthquake. We restored 88 out of 93 clipped waveforms of 38 broadband seismic stations of China Earthquake Networks (CEN). The epicenter distance of the nearest station to the epicenter that we can faithfully restore is only about 32 km. In order to investigate if the source parameters of earthquake could be determined exactly with the restored data, restored waveforms are utilized to get the mechanism of Lushan earthquake. We apply the generalized reflection-transmission coefficient matrix method to calculate the synthetic seismic records and simulated annealing method in inversion (Yao and Harkrider, 1983; Hao et al., 2012). We select 5 stations of CEN with the epicenter distance about 200km whose records aren't clipped and three-component velocity records are used. The result shows the strike, dip and rake angles of Lushan earthquake are 200o, 51o and 87o respectively, hereinafter "standard result". Then the clipped and restored seismic waveforms are applied respectively. The strike, dip and rake angles of clipped seismic waveforms are 184o, 53o and 72o respectively. The largest misfit of angle is 16o. In contrast, the strike, dip and rake angles of restored seismic waveforms are 198o, 51o and 87o respectively. It is very close to the "standard result". We also study the rupture history of Lushan earthquake constrained with the restored local broadband and teleseismic waves based on finite fault method (Hao et al., 2013). The result consists with that constrained with the strong motion and teleseismic waves (Hao et al., 2013), especially the location of the patch with larger slip. In real-time seismology, determining the source parameters as soon as possible is important. This method will help us to determine the mechanism of earthquake

  16. Fermionic models with superconducting circuits

    Energy Technology Data Exchange (ETDEWEB)

    Las Heras, Urtzi; Garcia-Alvarez, Laura; Mezzacapo, Antonio; Lamata, Lucas [University of the Basque Country UPV/EHU, Department of Physical Chemistry, Bilbao (Spain); Solano, Enrique [University of the Basque Country UPV/EHU, Department of Physical Chemistry, Bilbao (Spain); IKERBASQUE, Basque Foundation for Science, Bilbao (Spain)

    2015-12-01

    We propose a method for the efficient quantum simulation of fermionic systems with superconducting circuits. It consists in the suitable use of Jordan-Wigner mapping, Trotter decomposition, and multiqubit gates, be with the use of a quantum bus or direct capacitive couplings. We apply our method to the paradigmatic cases of 1D and 2D Fermi-Hubbard models, involving couplings with nearest and next-nearest neighbours. Furthermore, we propose an optimal architecture for this model and discuss the benchmarking of the simulations in realistic circuit quantum electrodynamics setups. (orig.)

  17. Circuit modeling for electromagnetic compatibility

    CERN Document Server

    Darney, Ian B

    2013-01-01

    Very simply, electromagnetic interference (EMI) costs money, reduces profits, and generally wreaks havoc for circuit designers in all industries. This book shows how the analytic tools of circuit theory can be used to simulate the coupling of interference into, and out of, any signal link in the system being reviewed. The technique is simple, systematic and accurate. It enables the design of any equipment to be tailored to meet EMC requirements. Every electronic system consists of a number of functional modules interconnected by signal links and power supply lines. Electromagnetic interference

  18. Relative ultrasound energy measurement circuit

    OpenAIRE

    Gustafsson, E.Martin I.; Johansson, Jonny; Delsing, Jerker

    2005-01-01

    A relative ultrasound energy estimation circuit has been designed in a standard 0.35-μm CMOS process, to be a part of a thumb size internet connected wireless ultrasound measurement system. This circuit measures the relative energy between received ultrasound pulses, and presents an output signal that is linear to the received energy. Post-layout simulations indicate 7 bit linearity for 500 mV input signals, 5 μsec startup and stop times, 2.6 mW power consumption during active state. The acti...

  19. Simplified design of filter circuits

    CERN Document Server

    Lenk, John

    1999-01-01

    Simplified Design of Filter Circuits, the eighth book in this popular series, is a step-by-step guide to designing filters using off-the-shelf ICs. The book starts with the basic operating principles of filters and common applications, then moves on to describe how to design circuits by using and modifying chips available on the market today. Lenk's emphasis is on practical, simplified approaches to solving design problems.Contains practical designs using off-the-shelf ICsStraightforward, no-nonsense approachHighly illustrated with manufacturer's data sheets

  20. Programming languages for circuit design.

    Science.gov (United States)

    Pedersen, Michael; Yordanov, Boyan

    2015-01-01

    This chapter provides an overview of a programming language for Genetic Engineering of Cells (GEC). A GEC program specifies a genetic circuit at a high level of abstraction through constraints on otherwise unspecified DNA parts. The GEC compiler then selects parts which satisfy the constraints from a given parts database. GEC further provides more conventional programming language constructs for abstraction, e.g., through modularity. The GEC language and compiler is available through a Web tool which also provides functionality, e.g., for simulation of designed circuits.

  1. Endogenous money, circuits and financialization

    OpenAIRE

    Malcolm Sawyer

    2013-01-01

    This paper locates the endogenous money approach in a circuitist framework. It argues for the significance of the credit creation process for the evolution of the economy and the absence of any notion of ‘neutrality of money’. Clearing banks are distinguished from other financial institutions as the providers of initial finance in a circuit whereas other financial institutions operate in a final finance circuit. Financialization is here viewed in terms of the growth of financial assets an...

  2. Does the placement of surgical clips within the excision cavity influence local control for patients treated with breast conserving surgery and irradiation?

    Energy Technology Data Exchange (ETDEWEB)

    Fein, Douglas A; Fowble, Barbara L; Hanlon, Alexandra L; Hoffman, John P; Sigurdson, Elin R; Eisenberg, Burton L

    1995-07-01

    PURPOSE: A number of authors have demonstrated the importance of using surgical clips to define the tumor bed in the treatment planning of early stage breast cancer. The clips have been useful in delineating the borders of the tangential fields especially for very medial and very lateral lesions as well as the boost volume. If surgical clips better define the tumor bed then a reduction in true or marginal recurrences should be appreciated. We sought to compare the incidence of breast recurrence in women with and without surgical clips controlling for other recognized prognostic factors. METHODS AND MATERIALS: Between 1980 and 1992, 1364 women with clinical Stage I or II invasive breast cancer underwent excisional biopsy, axillary dissection, and definitive irradiation. Median follow-up was 60 months. Median age was 55 years. Seventy-one percent of patients were path N0, 22% had 1-3 nodes and 7% had {>=} 4 nodes. Sixty-one percent were ER positive and 49% PR positive. Margin status was negative in 62%, positive in 10%, close in 9%, and unknown in 19%. Fifty-seven percent of women underwent a reexcision. Adjuvant chemotherapy {+-} tamoxifen was administered in 29%, and tamoxifen alone in 17%. Surgical clips were placed in the excision cavity in 556 patients while the other 808 did not have clips placed. All patients had a boost to the tumor bed. Patients had their boost planned with CT scanning or stereo shift radiographs. No significant differences between the 2 groups were noted for median age, T stage, nodal status, race, ER/PR receptor status, region irradiated, or tumor location. Patients without clips had negative margins less often, a higher rate of unknown or positive margins and more often received no adjuvant therapy compared to patients with surgical clips. RESULTS: Twenty-three and 27 patients with and without surgical clips, respectively developed a true or marginal recurrence in the treated breast. The actuarial probability of a breast recurrence was 2

  3. Does the placement of surgical clips within the excision cavity influence local control for patients treated with breast conserving surgery and irradiation?

    International Nuclear Information System (INIS)

    Fein, Douglas A.; Fowble, Barbara L.; Hanlon, Alexandra L.; Hoffman, John P.; Sigurdson, Elin R.; Eisenberg, Burton L.

    1995-01-01

    PURPOSE: A number of authors have demonstrated the importance of using surgical clips to define the tumor bed in the treatment planning of early stage breast cancer. The clips have been useful in delineating the borders of the tangential fields especially for very medial and very lateral lesions as well as the boost volume. If surgical clips better define the tumor bed then a reduction in true or marginal recurrences should be appreciated. We sought to compare the incidence of breast recurrence in women with and without surgical clips controlling for other recognized prognostic factors. METHODS AND MATERIALS: Between 1980 and 1992, 1364 women with clinical Stage I or II invasive breast cancer underwent excisional biopsy, axillary dissection, and definitive irradiation. Median follow-up was 60 months. Median age was 55 years. Seventy-one percent of patients were path N0, 22% had 1-3 nodes and 7% had ≥ 4 nodes. Sixty-one percent were ER positive and 49% PR positive. Margin status was negative in 62%, positive in 10%, close in 9%, and unknown in 19%. Fifty-seven percent of women underwent a reexcision. Adjuvant chemotherapy ± tamoxifen was administered in 29%, and tamoxifen alone in 17%. Surgical clips were placed in the excision cavity in 556 patients while the other 808 did not have clips placed. All patients had a boost to the tumor bed. Patients had their boost planned with CT scanning or stereo shift radiographs. No significant differences between the 2 groups were noted for median age, T stage, nodal status, race, ER/PR receptor status, region irradiated, or tumor location. Patients without clips had negative margins less often, a higher rate of unknown or positive margins and more often received no adjuvant therapy compared to patients with surgical clips. RESULTS: Twenty-three and 27 patients with and without surgical clips, respectively developed a true or marginal recurrence in the treated breast. The actuarial probability of a breast recurrence was 2% at

  4. Does the placement of surgical clips within the excision cavity influence local control for patients treated with breast-conserving surgery and irradiation?

    International Nuclear Information System (INIS)

    Fein, Douglas A.; Fowble, Barbara L.; Hanlon, Alexandra L.; Hoffman, John P.; Sigurdson, Elin R.; Eisenberg, Burton L.

    1996-01-01

    Purpose: A number of authors have demonstrated the importance of using surgical clips to define the tumor bed in the treatment planning of early-stage breast cancer. The clips have been useful in delineating the borders of the tangential fields, especially for very medial and very lateral lesions as well as the boost volume. If surgical clips better define the tumor bed, then a reduction in true or marginal recurrences should be appreciated. We sought to compare the incidence of breast recurrence in women with and without surgical clips, controlling for other recognized prognostic factors. Methods and Materials: Between 1980 and 1992, 1364 women with clinical Stage I or II invasive breast cancer underwent excisional biopsy, axillary dissection, and definitive irradiation. Median follow-up was 60 months. Median age was 55 years. Seventy-one percent of patients were path N0, 22% had one to three nodes, and 7% had > four nodes. Sixty-one percent were ER positive and 49% PR positive. Margin status was negative in 62%, positive in 10%, close in 9%, and unknown in 19%. Fifty-seven percent of women underwent a reexcision. Adjuvant chemotherapy + tamoxifen was administered in 29%, and tamoxifen alone in 17%. Surgical clips were placed in the excision cavity in 556 patients, while the other 808 did not have clips placed. All patients had a boost to the tumor bed. Patients had their boost planned with CT scanning or stereo shift radiographs. No significant differences between the two groups were noted for median age, T stage, nodal status, race, ER/PR receptor status, region irradiated, or tumor location. Patients without clips had negative margins less often, a higher rate of unknown or positive margins and more often received no adjuvant therapy compared to patients with surgical clips. Results: Twenty-five and 27 patients with and without surgical clips, respectively, developed a true or marginal recurrence in the treated breast. The actuarial probability of a breast

  5. Implementation of Chua's circuit using simulated inductance

    Science.gov (United States)

    Gopakumar, K.; Premlet, B.; Gopchandran, K. G.

    2011-05-01

    In this study we describe how to build an inductorless version of the classic Chua's circuit. A suitable inductor for Chua's circuit is often hard to procure. The required inductor for the circuit is designed using simple circuit elements such as resistors, capacitors and operational amplifiers. The complete circuit can be implemented by using off-the-shelf components, and it can readily be integrated on a single chip. This design of Chua's circuit allows the original dynamics to be slowed down to just a few hertz, enabling implementation of sophisticated control schemes without severe time restrictions. Another novel feature of the circuit is that losses associated with capacitors due to leakages can easily be compensated by providing negative resistance using the same setup. The chaotic behaviour of the circuit is verified by PSpice and Multisim simulation and also by experimental study on a circuit breadboard. The results give excellent agreement with each other and with the results of previous investigators.

  6. Patterns and Meanings of English Words through Word Formation Processes of Acronyms, Clipping, Compound and Blending Found in Internet-Based Media

    Directory of Open Access Journals (Sweden)

    Rio Rini Diah Moehkardi

    2017-02-01

    Full Text Available This research aims to explore the word-formation process in English new words found in the internet-based media through acronym, compound,  clipping and blending and their meanings. This study applies Plag’s (2002 framework of acronym and compound; Jamet’s (2009 framework of clipping, and Algeo’s framework (1977 in Hosseinzadeh  (2014 for blending. Despite the  formula established in each respective framework,  there could be occurrences  of novelty and modification on how words are formed and  how meaning developed in  the newly formed words. The research shows that well accepted acronyms can become real words by taking lower case and affixation. Some acronyms initialized non-lexical words, used non initial letters, and used letters and numbers that pronounced the same with the words they represent. Compounding also includes numbers as the element member of the compound. The nominal nouns are likely to have metaphorical and idiomatic meanings. Some compounds evolve to new and more specific meaning. The study also finds that back-clipping is the most dominant clipping. In blending, the sub-category clipping of blending, the study finds out that when clipping takes place, the non-head element is back-clipped and the head is fore-clipped.

  7. Judgments of Nonverbal Behaviour by Children with High-Functioning Autism Spectrum Disorder: Can They Detect Signs of Winning and Losing from Brief Video Clips?

    Science.gov (United States)

    Ryan, Christian; Furley, Philip; Mulhall, Kathleen

    2016-01-01

    Typically developing children are able to judge who is winning or losing from very short clips of video footage of behaviour between active match play across a number of sports. Inferences from "thin slices" (short video clips) allow participants to make complex judgments about the meaning of posture, gesture and body language. This…

  8. ClipCard: Sharable, Searchable Visual Metadata Summaries on the Cloud to Render Big Data Actionable

    Science.gov (United States)

    Saripalli, P.; Davis, D.; Cunningham, R.

    2013-12-01

    Research firm IDC estimates that approximately 90 percent of the Enterprise Big Data go un-analyzed, as 'dark data' - an enormous corpus of undiscovered, untagged information residing on data warehouses, servers and Storage Area Networks (SAN). In the geosciences, these data range from unpublished model runs to vast survey data assets to raw sensor data. Many of these are now being collected instantaneously, at a greater volume and in new data formats. Not all of these data can be analyzed, nor processed in real time, and their features may not be well described at the time of collection. These dark data are a serious data management problem for science organizations of all types, especially ones with mandated or required data reporting and compliance requirements. Additionally, data curators and scientists are encouraged to quantify the impact of their data holdings as a way to measure research success. Deriving actionable insights is the foremost goal of Big Data Analytics (BDA), which is especially true with geoscience, given its direct impact on most of the pressing global issues. Clearly, there is a pressing need for innovative approaches to making dark data discoverable, measurable, and actionable. We report on ClipCard, a Cloud-based SaaS analytic platform for instant summarization, quick search, visualization and easy sharing of metadata summaries form the Dark Data at hierarchical levels of detail, thus rendering it 'white', i.e., actionable. We present a use case of the ClipCard platform, a cloud-based application which helps generate (abstracted) visual metadata summaries and meta-analytics for environmental data at hierarchical scales within and across big data containers. These summaries and analyses provide important new tools for managing big data and simplifying collaboration through easy to deploy sharing APIs. The ClipCard application solves a growing data management bottleneck by helping enterprises and large organizations to summarize, search

  9. Left cardiac chambers reverse remodeling after percutaneous mitral valve repair with the MitraClip system.

    Science.gov (United States)

    Scandura, Salvatore; Ussia, Gian Paolo; Capranzano, Piera; Caggegi, Anna; Sarkar, Kunal; Cammalleri, Valeria; Mangiafico, Sarah; Chiarandà, Marta; Immè, Sebastiano; Di Pasqua, Fabio; Pistritto, Anna Maria; Millan, Giovanni; Tamburino, Corrado

    2012-10-01

    Successful mitral valve surgical repair, decreasing volume overload, has been shown to provide reverse left ventricular (LV) and/or left atrial remodeling in most patients. Percutaneous mitral valve repair with the MitraClip system (Abbott, Abbott Park, IL) has been associated with favorable clinical outcomes in patients with mitral regurgitation at high risk of surgery. However, specific data on left cardiac chambers reverse remodeling after such procedures are limited. This was a prospective observational study of consecutive patients at high risk of surgery, with moderate-to-severe or severe mitral regurgitation undergoing MitraClip system implantation. Follow-up echocardiography was performed at 6 months. The evaluated parameters were the LV end-diastolic and end-systolic volume indexes, LV sphericity index, LV ejection fraction, and left atrial volume index. Reverse LV remodeling was defined as a decrease of 10% in the LV end-diastolic volume index. The study population included 44 patients: 14 with degenerative and 30 with functional mitral regurgitation. At 6 months of follow-up, significant reductions in the median and interquartile range of the sphericity index (from 0.57 [interquartile range 0.54-0.62] to 0.54 [interquartile range 0.50-0.58]; P interquartile range 63.0-102.2] to 60.7 mL/m(2) [50.8-84.4]; P interquartile range 28.2-70.5] to 28.9 mL/m(2) [interquartile range 22.2-55.8]; P interquartile range 30.0-55.0%] to 46.0% [interquartile range 35.0-58.0%]; P < .001) from baseline to 6 months. Minor differences in the left atrial volume index were observed. Reverse remodeling, according to the specified definition, was observed in 77.3% of the patients. The present study reports positive LV reshape effects after mitral valve repair with the MitraClip system, showing significant improvements in LV size and function. Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  10. Advanced circuit simulation using Multisim workbench

    CERN Document Server

    Báez-López, David; Cervantes-Villagómez, Ofelia Delfina

    2012-01-01

    Multisim is now the de facto standard for circuit simulation. It is a SPICE-based circuit simulator which combines analog, discrete-time, and mixed-mode circuits. In addition, it is the only simulator which incorporates microcontroller simulation in the same environment. It also includes a tool for printed circuit board design.Advanced Circuit Simulation Using Multisim Workbench is a companion book to Circuit Analysis Using Multisim, published by Morgan & Claypool in 2011. This new book covers advanced analyses and the creation of models and subcircuits. It also includes coverage of transmissi

  11. Digital circuit boards mach 1 GHz

    CERN Document Server

    Morrison, Ralph

    2012-01-01

    A unique, practical approach to the design of high-speed digital circuit boards The demand for ever-faster digital circuit designs is beginning to render the circuit theory used by engineers ineffective. Digital Circuit Boards presents an alternative to the circuit theory approach, emphasizing energy flow rather than just signal interconnection to explain logic circuit behavior. The book shows how treating design in terms of transmission lines will ensure that the logic will function, addressing both storage and movement of electrical energy on these lines. It cove

  12. Clocking Scheme for Switched-Capacitor Circuits

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper

    1998-01-01

    A novel clocking scheme for switched-capacitor (SC) circuits is presented. It can enhance the understanding of SC circuits and the errors caused by MOSFET (MOS) switches. Charge errors, and techniques to make SC circuits less sensitive to them are discussed.......A novel clocking scheme for switched-capacitor (SC) circuits is presented. It can enhance the understanding of SC circuits and the errors caused by MOSFET (MOS) switches. Charge errors, and techniques to make SC circuits less sensitive to them are discussed....

  13. Unbalanced Neuronal Circuits in Addiction

    OpenAIRE

    Volkow, Nora D.; Wang, Gen-Jack; Tomasi, Dardo; Baler, Ruben D.

    2013-01-01

    Through sequential waves of drug-induced neurochemical stimulation, addiction co-opts the brain's neuronal circuits that mediate reward, motivation, , to behavioral inflexibility and a severe disruption of self-control and compulsive drug intake. Brain imaging technologies have allowed neuroscientists to map out the neural landscape of addiction in the human brain and to understand how drugs modify it.

  14. A Low Noise Electronic Circuit

    NARCIS (Netherlands)

    Annema, Anne J.; Leenaerts, Dominicus M.W.; de Vreede, Petrus W.H.

    2002-01-01

    An electronic circuit, which can be used as a Low Noise Amplifier (LNA), comprises two complementary Field Effect Transistors (M1, M2; M5, M6), each having a gate, a source and a drain. The gates are connected together as a common input terminal, and the drains are connected together as a

  15. Circuit design for RF transceivers

    CERN Document Server

    Leenaerts, Domine; Vaucher, Cicero S

    2007-01-01

    Second edition of this successful 2001 RF Circuit Design book, has been updated, latest technology reviews have been added as well as several actual case studies. Due to the authors being active in industry as well as academia, this should prove to be an essential guide on RF Transceiver Design for students and engineers.

  16. Integrated Circuit Stellar Magnitude Simulator

    Science.gov (United States)

    Blackburn, James A.

    1978-01-01

    Describes an electronic circuit which can be used to demonstrate the stellar magnitude scale. Six rectangular light-emitting diodes with independently adjustable duty cycles represent stars of magnitudes 1 through 6. Experimentally verifies the logarithmic response of the eye. (Author/GA)

  17. Simulated annealing and circuit layout

    NARCIS (Netherlands)

    Aarts, E.H.L.; Laarhoven, van P.J.M.

    1991-01-01

    We discuss the problem of approximately sotvlng circuit layout problems by simulated annealing. For this we first summarize the theoretical concepts of the simulated annealing algorithm using Ihe theory of homogeneous and inhomogeneous Markov chains. Next we briefly review general aspects of the

  18. MicroRNA transfection and AGO-bound CLIP-seq data sets reveal distinct determinants of miRNA action

    DEFF Research Database (Denmark)

    Wen, Jiayu; Parker, Brian J; Jacobsen, Anders

    2011-01-01

    the predictive effect of target flanking features. We observe distinct target determinants between expression-based and CLIP-based data. Target flanking features such as flanking region conservation are an important AGO-binding determinant-we hypothesize that CLIP experiments have a preference for strongly bound......Microarray expression analyses following miRNA transfection/inhibition and, more recently, Argonaute cross-linked immunoprecipitation (CLIP)-seq assays have been used to detect miRNA target sites. CLIP and expression approaches measure differing stages of miRNA functioning-initial binding of the mi...... miRNP-target interactions involving adjacent RNA-binding proteins that increase the strength of cross-linking. In contrast, seed-related features are major determinants in expression-based studies, but less so for CLIP-seq studies, and increased miRNA concentrations typical of transfection studies...

  19. Image quality and artefact generation post-cerebral aneurysm clipping using a 64-row multislice computer tomography angiography (MSCTA) technology: A retrospective study and review of the literature.

    Science.gov (United States)

    Zachenhofer, Iris; Cejna, Manfred; Schuster, Antonius; Donat, Markus; Roessler, Karl

    2010-06-01

    Computed tomography angiography (CTA) is a time and cost saving investigation for postoperative evaluation of clipped cerebral aneurysm patients. A retrospective study was conducted to analyse image quality and artefact generation due to implanted aneurysm clips using a new technology. MSCTA was performed pre- and postoperatively using a Philips Brilliance 64-detector-row CT scanner. Altogether, 32 clipping sites were analysed in 27 patients (11 female and 16 male, mean ages 52a, from 24 to 72 years). Clip number per aneurysm was 2.3 mean (from 1 to 4), 54 clips were made of titanium alloy and 5 of cobalt alloy. Altogether, image quality was rated 1.8 mean, using a scale from 1 (very good) to 5 (unserviceable) and clip artefacts were rated 2.4 mean, using a 5 point rating scale (1 no artefacts, 5 unserviceable due to artefacts). A significant loss of image quality and rise of artefacts was found when using cobalt alloy clips (1.4 versus 4.2 and 2.1 versus 4.0). In 72% of all investigations, an excellent image quality was found. Excluding the cobalt clip group, 85% of scans showed excellent image quality. Artefacts were absent or minimal (grade 1 or 2) in 69% of all investigations and in 81% in the pure titanium clip group. In 64-row MSCTA of good image quality with low artefacts, it was possible to detect small aneurysm remnants of 2mm size in individual patients. By using titanium alloy clips, in our study up to 85% of postoperative CTA images were of excellent quality with absent or minimal artefacts in 81% and seem adequate to detect small aneurysm remnants. Copyright 2010 Elsevier B.V. All rights reserved.

  20. Rescue endoscopic bleeding control for nonvariceal upper gastrointestinal hemorrhage using clipping and detachable snaring.

    Science.gov (United States)

    Lee, J H; Kim, B K; Seol, D C; Byun, S J; Park, K H; Sung, I K; Park, H S; Shim, C S

    2013-06-01

    Nonvariceal upper gastrointestinal (UGI) bleeding recurs after appropriate endoscopic therapy in 10 % - 15 % of cases. The mortality rate can be as high as 25 % when bleeding recurs, but there is no consensus about the best modality for endoscopic re-treatment. The aim of this study was to evaluate clipping and detachable snaring (CDS) for rescue endoscopic control of nonvariceal UGI hemorrhage. We report a case series of seven patients from a Korean tertiary center who underwent endoscopic hemostasis using the combined method of detachable snares with hemoclips. The success rate of endoscopic hemostasis with CDS was 86 %: six of the seven patients who had experienced primary endoscopic treatment failure or recurrent bleeding after endoscopic hemostasis were treated successfully. In conclusion, rescue endoscopic bleeding control by means of CDS is an option for controlling nonvariceal UGI bleeding when no other method of endoscopic treatment for recurrent bleeding and primary hemostatic failure is possible. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Worst-case residual clipping noise power model for bit loading in LACO-OFDM

    KAUST Repository

    Zhang, Zhenyu

    2018-03-19

    Layered ACO-OFDM enjoys better spectral efficiency than ACO-OFDM, but its performance is challenged by residual clipping noise (RCN). In this paper, the power of RCN of LACO-OFDM is analyzed and modeled. As RCN is data-dependent, the worst-case situation is considered. A worst-case indicator is defined for relating the power of RCN and the power of noise at the receiver, wherein a linear relation is shown to be a practical approximation. An LACO-OFDM bit-loading experiment is performed to examine the proposed RCN power model for data rates of 6 to 7 Gbps. The experiment\\'s results show that accounting for RCN has two advantages. First, it leads to better bit loading and achieves up to 59% lower overall bit-error rate (BER) than when the RCN is ignored. Second, it balances the BER across layers, which is a desired property from a channel coding perspective.

  2. Using CLIPS in a distributed system: The Network Control Center (NCC) expert system

    Science.gov (United States)

    Wannemacher, Tom

    1990-01-01

    This paper describes an intelligent troubleshooting system for the Help Desk domain. It was developed on an IBM-compatible 80286 PC using Microsoft C and CLIPS and an AT&T 3B2 minicomputer using the UNIFY database and a combination of shell script, C programs and SQL queries. The two computers are linked by a lan. The functions of this system are to help non-technical NCC personnel handle trouble calls, to keep a log of problem calls with complete, concise information, and to keep a historical database of problems. The database helps identify hardware and software problem areas and provides a source of new rules for the troubleshooting knowledge base.

  3. Water and exchangeable sodium in Goldblatt two-kidney, two-clip hypertensive rats

    International Nuclear Information System (INIS)

    Mac Cormack, W.P.; Roson, M.I.; Maquieira, M.K.; Mendez, M.A.; Santoro, F.M.; Morera, S.; de la Riva, I.J.

    1986-01-01

    Exchangeable 22 Na (ExNa), total body water (TBW) and the inulin space (InSp) were determined in two-kidney, two-clip (2K-2C) hypertensive and sham operated (normotensive) control rats 6-8 weeks after surgery. TBW (ml/kg lean body weight) was the same in hypertensive and sham rats. In contrast, ExNa (mEq/kglbw) and InSp (ml/kglbw) significantly increased (p less than 0.01) in rats whose hypertension did not exceed 170 mmHg. Consequently, sham, moderate hypertensive (less than 170 mmHg) and severe hypertensive (less than 170 mmHg) animals showed equal TBW but differed in body water distribution in that moderately hypertensive animals displayed a redistribution of water in favor of the extracellular space

  4. The First Awake Clipping of a Brain Aneurysm in Malaysia and in ASEAN: Achieving International Standards.

    Science.gov (United States)

    Idris, Zamzuri; Kandasamy, Regunath; Neoh, Yee Yik; Abdullah, Jafri Malin; Wan Hassan, Wan Mohd Nazaruddin; Mat Hassan, Mohd Erham

    2018-02-01

    World-renowned neurosurgeon, Professor Saleem Abdulrauf, has been featured in several medical journals for his successful "Awake Brain Aneurysm Surgery". Regarded as a "world first", this surgery, involves clipping un-ruptured brain aneurysms while patients are awake. Only one or two neurosurgery centres worldwide are capable of this. Performing the surgery while the patient is awake lowers risks of brain ischemia with neurological deficits and ventilator associated morbidities. The technique has been viewed as the start of a new era in brain surgery. Physicians from the Universiti Sains Malaysia (USM) School of Medical Sciences, at the Health Campus in Kelantan, headed by Professor Dr Zamzuri Idris (neurosurgeon) and Dr Wan Mohd Nazaruddin Wan Hassan (neuroanaesthetist), recently performed a similar procedure, the first such surgery in Malaysia and Southeast Asia. The USM team can therefore be considered to be among the first few to have done this brain surgery and achieved successful patient outcomes.

  5. Worst-case residual clipping noise power model for bit loading in LACO-OFDM

    KAUST Repository

    Zhang, Zhenyu; Chaaban, Anas; Shen, Chao; Elgala, Hany; Ng, Tien Khee; Ooi, Boon S.; Alouini, Mohamed-Slim

    2018-01-01

    Layered ACO-OFDM enjoys better spectral efficiency than ACO-OFDM, but its performance is challenged by residual clipping noise (RCN). In this paper, the power of RCN of LACO-OFDM is analyzed and modeled. As RCN is data-dependent, the worst-case situation is considered. A worst-case indicator is defined for relating the power of RCN and the power of noise at the receiver, wherein a linear relation is shown to be a practical approximation. An LACO-OFDM bit-loading experiment is performed to examine the proposed RCN power model for data rates of 6 to 7 Gbps. The experiment's results show that accounting for RCN has two advantages. First, it leads to better bit loading and achieves up to 59% lower overall bit-error rate (BER) than when the RCN is ignored. Second, it balances the BER across layers, which is a desired property from a channel coding perspective.

  6. Classical surgical approach and treatment with clips of extracranial internal carotid artery berry aneurysm

    Directory of Open Access Journals (Sweden)

    Haris Vukas

    2016-06-01

    Full Text Available Introduction: We can define extracranial carotid artery aneurysm (ECAA as bulb dilatation greater than 200% of the diameter of the internal carotid artery (ICA or in a case of common carotid artery (CCA greater than 150% of the diameter. Surgical intervention is required for the treatment of this disease.Case report: This study presents an open vascular surgical procedure to resolve ECAA. We report a case of 61 years old woman with an extracranial internal carotid artery berry aneurysm, presented with a headache and dizziness when turning the head aside. Classic open surgery was performed and the lumen of berry aneurysm was separated with three clips from the lumen of ICA.Conclusions: The open surgical approach is the method of choice for the treatment of extracranial internal carotid artery pathological conditions.

  7. Local Contrast Enhancement Utilizing Bidirectional Switching Equalization of Separated and Clipped Subhistograms

    Directory of Open Access Journals (Sweden)

    Haidi Ibrahim

    2014-01-01

    Full Text Available Digital image contrast enhancement methods that are based on histogram equalization technique are still useful for the use in consumer electronic products due to their simple implementation. However, almost all the suggested enhancement methods are using global processing technique, which does not emphasize local contents. Therefore, this paper proposes a new local image contrast enhancement method, based on histogram equalization technique, which not only enhances the contrast, but also increases the sharpness of the image. Besides, this method is also able to preserve the mean brightness of the image. In order to limit the noise amplification, this newly proposed method utilizes local mean-separation, and clipped histogram bins methodologies. Based on nine test color images and the benchmark with other three histogram equalization based methods, the proposed technique shows the best overall performance.

  8. Treatment of Traumatic Esophagopleural Fistula Using the Over-the-Scope-Clip System.

    Science.gov (United States)

    Kim, Ji Hyoung; Park, Jong-Jae; Jung, Il Woo; Kim, Sang Hoon; Kim, Hee Dong; Choe, Jung Wan; Joo, Moon Kyung; Kim, Hyun Gu

    2015-09-01

    Esophagopleural fistula (EPF) is a rare condition that is usually accompanied by severe infection and life-threatening morbidity. Here, we report the successful treatment of an EPF by closing an esophageal orifice using the over-the-scope-clip (OTSC) system without postprocedural complications. A 41-year-old man had serious thoracic and abdominal trauma due to a traffic accident. Computed tomography revealed findings suggestive of esophageal rupture due to Boerhaave syndrome. An emergent explorative operation was performed for primary repair with the insertion of a vacuum-assisted closure device. A postoperative upper gastrointestinal series revealed an EPF tract connecting the left pleural space and distal esophagus. We performed an endoscopic procedure using the "traumatic-type"OTSC to seal the EPF, and the esophageal orifice was completely healed 2 weeks postoperatively. The OTSC system might represent a safe and feasible modality for the treatment of EPF.

  9. The voltage—current relationship and equivalent circuit implementation of parallel flux-controlled memristive circuits

    International Nuclear Information System (INIS)

    Bao Bo-Cheng; Feng Fei; Dong Wei; Pan Sai-Hu

    2013-01-01

    A flux-controlled memristor characterized by smooth cubic nonlinearity is taken as an example, upon which the voltage—current relationships (VCRs) between two parallel memristive circuits — a parallel memristor and capacitor circuit (the parallel MC circuit), and a parallel memristor and inductor circuit (the parallel ML circuit) — are investigated. The results indicate that the VCR between these two parallel memristive circuits is closely related to the circuit parameters, and the frequency and amplitude of the sinusoidal voltage stimulus. An equivalent circuit model of the memristor is built, upon which the circuit simulations and experimental measurements of both the parallel MC circuit and the parallel ML circuit are performed, and the results verify the theoretical analysis results

  10. Preoperative Prediction of the Necessity for Anterior Clinoidectomy During Microsurgical Clipping of Ruptured Posterior Communicating Artery Aneurysms.

    Science.gov (United States)

    Kamide, Tomoya; Burkhardt, Jan-Karl; Tabani, Halima; Safaee, Michael M; Lawton, Michael T

    2018-01-01

    Although most posterior communicating artery (PCoA) aneurysms can be clipped easily with excellent results, some require anterior clinoidectomy for safe and complete clipping. To review our microsurgical series of ruptured PCoA aneurysms and identify the preoperative predictors for anterior clinoidectomy during microsurgical clipping for PCoA aneurysms. Results from microsurgical clipping of 104 patients with ruptured PCoA aneurysms were reviewed retrospectively. Distances and angles were obtained from computed tomographic angiography and compared between the anterior and nonanterior clinoidectomy groups. Anterior clinoidectomy was required in 19 of the 104 cases (18%). None developed surgical complications due to anterior clinoid process (ACP) resection, including postoperative visual deficit. Univariate and multivariate analyses revealed that the distances from the ACP tip to the aneurysmal proximal neck and from the ACP line to the aneurysmal proximal neck were statistically significant predictive factors for the need of anterior clinoidectomy. Based on a receiver operating characteristic analysis, the distances from the ACP tip to the aneurysmal proximal neck PCoA aneurysm surgery, the distances from the ACP tip to the aneurysmal proximal neck and from the ACP line to the aneurysmal proximal neck were both found to be useful predictors of whether anterior clinoidectomy was required. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Advanced technical skills are required for microsurgical clipping of posterior communicating artery aneurysms in the endovascular era.

    Science.gov (United States)

    Sanai, Nader; Caldwell, Nolan; Englot, Dario J; Lawton, Michael T

    2012-08-01

    Many neurosurgeons feel competent clipping posterior communicating artery (PCoA) aneurysms and include this lesion in their practice. However, endovascular therapy removes simple aneurysms that would have been easiest to clip with the best results. What remains are aneurysms with complex anatomy and technical challenges that are not well described. A contemporary surgical series with PCoA aneurysms is reviewed to define the patients, microsurgical techniques, and outcomes in current practice. A total of 218 patients had 218 PCoA aneurysms that were treated microsurgically during an 11-year period. Complexities influencing aneurysm management included (1) large/giant size; (2) fetal posterior cerebral artery; (3) previous coiling; (4) anterior clinoidectomy; (5) adherence of the anterior choroidal artery (AChA); (6) intraoperative aneurysm rupture; (7) complex clipping; and (8) atherosclerotic calcification. Simple PCoA aneurysms were encountered in 113 patients (51.8%) and complex aneurysms in 105 (48.2%). Adherent AChA (13.8%) and intraoperative rupture (11.5%) were the most common complexities. Simple aneurysms had favorable outcomes in 86.6% of patients, whereas aneurysms with 1 or multiple complexities had favorable outcomes in 78.2% and 75.0%, respectively. Intraoperative rupture (P PCoA aneurysms requires advanced techniques including clinoidectomy, AChA microdissection, complex clipping, and facility with intraoperative rupture. Microsurgery is recommended for recurrent aneurysms after coiling, complex branches, aneurysms causing oculomotor nerve palsy, multiple aneurysms, and patients with hematomas.

  12. A comparison of CLIPS- and LISP-based approaches to the development of a real-time expert system

    Science.gov (United States)

    Frainier, R.; Groleau, N.; Bhatnagar, R.; Lam, C.; Compton, M.; Colombano, S.; Lai, S.; Szolovits, P.; Manahan, M.; Statler, I.

    1990-01-01

    This paper describes an ongoing expert system development effort started in 1988 which is evaluating both CLIPS- and LISP- based approaches. The expert system is being developed to a project schedule and is planned for flight on Space Shuttle Mission SLS-2 in 1992. The expert system will help astronauts do the best possible science for a vestibular physiology experiment already scheduled for that mission. The system gathers and reduces data from the experiment, flags 'interesting' results, and proposes changes in the experiment both to exploit the in-flight observations and to stay within the time allowed by Mission Control for the experiment. These tasks must all be performed in real time. Two Apple Macintosh computers are used. The CLIPS- and LISP- based environments are layered above the Macintosh computer Operating System. The 'CLIPS-based' environment includes CLIPS and HyperCard. The LlSP-based environment includes Common LISP, Parmenides (a frame system), and FRuleKit (a rule system). Important evaluation factors include ease of programming, performance against real-time requirements, usability by an astronaut, robustness, and ease of maintenance. Current results on the factors of ease of programming, performance against real-time requirements, and ease of maintenance are discussed.

  13. Comparative gas-exchange in leaves of intact and clipped, natural and planted cherrybark oak (Quercus pagoda Raf.) seedlings

    Science.gov (United States)

    Brian R. Lockhart; John D. Hodges

    2005-01-01

    Gas-exchange measurements, including C022-exchange rate (net photosynthesis), stomatal conductance, and transpiration, were conducted on intact and clipped cherrybark oak (Quercus pagoda Raf.) seedlings growing in the field and in a nursery bed. Seedlings in the field, released from midstory and understory woody competition,...

  14. Use of Avoidance Tests for Investigating Potential of the Earthworm Eisenia fetida to Improve Composting of Grass Clippings

    NARCIS (Netherlands)

    Illmer, P.; Liebensteiner, M.

    2011-01-01

    The earthworm Eisenia fetida is the most commonly used worm for worm-supported composting of organic residues. Within the present study, the potential of E. fetida for decomposing grass clippings, an organic waste which usually causes anoxic conditions and thus insufficient degradation in the course

  15. International Subarachnoid Aneurysm Trial 2009 : Endovascular Coiling of Ruptured Intracranial Aneurysms Has No Significant Advantage Over Neurosurgical Clipping

    NARCIS (Netherlands)

    Bakker, Nicolaas A.; Metzemaekers, Jan D. M.; Groen, Rob J. M.; Mooij, Jan Jakob A.; Van Dijk, J. Marc C.

    In the May 2009 issue of The Lancet Neurology, the 5-year follow-up results of the International Subarachnoid Aneurysm Trial (ISAT) were published. The authors concluded that, although the significant difference between coiling and neurosurgical clipping of ruptured intracranial aneurysms in terms

  16. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling

    NARCIS (Netherlands)

    Westerlaan, H. E.; Gravendeel, J.; Fiore, D.; Metzemaekers, J. D. M.; Groen, R. J. M.; Mooij, J. J. A.; Oudkerk, M.

    2007-01-01

    Introduction We sought to establish whether CT angiography (CTA) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (IA-DSA). Methods Over the period April 2003 to January 2006 in

  17. Dynamic-range reduction by peak clipping or compression and its effects on phoneme perception in hearing-impaired listeners

    NARCIS (Netherlands)

    Dreschler, W. A.

    1988-01-01

    In this study, differences between dynamic-range reduction by peak clipping and single-channel compression for phoneme perception through conventional hearing aids have been investigated. The results from 16 hearing-impaired listeners show that compression limiting yields significantly better

  18. Single loop-and-clips technique (KING closure) for gastrotomy closure after transgastric ovariectomy: a survival experiment

    Czech Academy of Sciences Publication Activity Database

    Ryska, O.; Martinek, J.; Filípková, T.; Doležel, R.; Juhásová, Jana; Motlík, Jan; Zavoral, M.; Ryska, M.

    2012-01-01

    Roč. 7, č. 4 (2012), s. 233-239 ISSN 1895-4588 R&D Projects: GA MZd NS9994 Institutional research plan: CEZ:AV0Z50450515 Keywords : natural orifice transluminal endoscopic surgery * gastric closure * clips * endoloop Subject RIV: FJ - Surgery incl. Transplants Impact factor: 0.757, year: 2012

  19. Endoscopic Management of Gastrointestinal Leaks and Bleeding with the Over-the-Scope Clip: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Mahesh Kumar Goenka

    2017-01-01

    Full Text Available Background/Aims The over-the-scope clip (OTSC is a device used for endoscopic closure of perforations, leaks and fistulas, and for endoscopic hemostasis. To evaluate the clinical effectiveness and safety of OTSC. Methods Between October 2013 and November 2015, 12 patients underwent OTSC placement by an experienced endoscopist. OTSC was used for the closure of gastrointestinal (GI leaks and fistula in six patients, three of which were iatrogenic (esophageal, gastric, and duodenal and three of which were inflammatory. In six patients, OTSC was used for hemostasis of non-variceal upper GI bleeding. Endoscopic tattooing using India ink was used to assist the accurate placement of the clip. Results All subjects except one with a colonic defect experienced immediate technical success as well as long-term clinical success, during a mean follow-up of 6 weeks. Only one clip was required to close each of the GI defects and to achieve hemostasis in all patients. There were no misfirings or complications of clips. The procedure was well tolerated, and patients were hospitalized for an average of 8 days (range, 3 to 10. Antiplatelet therapy was continued in patients with GI bleeding. Conclusions In our experience, OTSC was safe and effective for the closure of GI defect and to achieve hemostasis of non-variceal GI bleeding.

  20. A meta-analysis of MitraClip system versus surgery for treatment of severe mitral regurgitation

    DEFF Research Database (Denmark)

    Wan, Benjamin; Rahnavardi, Mohammad; Tian, David H

    2013-01-01

    to the surgical group (17.2% vs. 0.4%; P.... The purpose of this meta-analysis is to compare the safety, clinical efficacy, and survival outcomes of MitraClip implantation with surgical correction of severe MR. METHODS: Six electronic databases were searched for original published studies from January 2000 to August 2013. Two reviewers independently...