WorldWideScience

Sample records for clinically significant portal

  1. Shear-wave elastography of the liver and spleen identifies clinically significant portal hypertension

    DEFF Research Database (Denmark)

    Jansen, Christian; Bogs, Christopher; Verlinden, Wim

    2017-01-01

    BACKGROUND & AIMS: Clinically significant portal hypertension (CSPH) is associated with severe complications and decompensation of cirrhosis. Liver stiffness measured either by transient elastography (TE) or Shear-wave elastography (SWE) and spleen stiffness by TE might be helpful in the diagnosis...... correlate with portal pressure and can both be used as a non-invasive method to investigate CSPH. Even though external validation is still missing, these algorithms to rule-out and rule-in CSPH using sequential SWE of liver and spleen might change the clinical practice....

  2. Imaging and clinical significance of hepatic portal venous gas seen in adult patients

    International Nuclear Information System (INIS)

    Aikawa, Hisayuki; Mori, Hiromu; Miyake, Hidetoshi

    1994-01-01

    In 10 adult patients with hepatic portal venous gas (HPVG), the clinical significance of HPVG and the efficacy of X-ray computed tomography (CT) were evaluated. HPVC was associated with ischemic bowel disease (n=3), trauma (n=4), liver abscess (n=1), sepsis (n=1) and unknown etiology (n=1). The diagnostic ability of CT for the detection of HPVG was far superior to that of plain abnormal radiograph. Of 9 patients who underwent CT, HPVG located in the left hepatic lobe in all patients, and also in right hepatic lobe in 7 patients. Gas could be recognized in the left lobe and the anterior segment of the right lobe more clearly than in the posterior segment of the right lobe because of its larger amount of intravenous collection. The mortality rate of our cases was 100%. Gas was demonstrated simultaneously in the portal vein radicles and hepatic veins on CT in 4 patients with no clinical evidence of sepsis, which suggested the possibility of intraparenchymal shift of gas from the portal vein into the hepatic vein. In a single case with sepsis, gas was noted in various vessels, including arteries, in addition to the portal venous system. The authors conclude that HPVG is still a grave sign in Japan and prompt appropriate treatment is required. CT may be of great value in the early detection of HPVG and may indicate its etiology. (author)

  3. A Meta-analysis for the Diagnostic Performance of Transient Elastography for Clinically Significant Portal Hypertension.

    Science.gov (United States)

    You, Myung-Won; Kim, Kyung Won; Pyo, Junhee; Huh, Jimi; Kim, Hyoung Jung; Lee, So Jung; Park, Seong Ho

    2017-01-01

    We aimed to evaluate the correlation between liver stiffness measurement using transient elastography (TE-LSM) and hepatic venous pressure gradient and the diagnostic performance of TE-LSM in assessing clinically significant portal hypertension through meta-analysis. Eleven studies were included from thorough literature research and selection processes. The summary correlation coefficient was 0.783 (95% confidence interval [CI], 0.737-0.823). Summary sensitivity, specificity and area under the hierarchical summary receiver operating characteristic curve (AUC) were 87.5% (95% CI, 75.8-93.9%), 85.3 % (95% CI, 76.9-90.9%) and 0.9, respectively. The subgroup with low cut-off values of 13.6-18 kPa had better summary estimates (sensitivity 91.2%, specificity 81.3% and partial AUC 0.921) than the subgroup with high cut-off values of 21-25 kPa (sensitivity 71.2%, specificity 90.9% and partial AUC 0.769). In summary, TE-LSM correlated well with hepatic venous pressure gradient and represented good diagnostic performance in diagnosing clinically significant portal hypertension. For use as a sensitive screening tool, we propose using low cut-off values of 13.6-18 kPa in TE-LSM. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. Clinical role of non-invasive assessment of portal hypertension.

    Science.gov (United States)

    Bolognesi, Massimo; Di Pascoli, Marco; Sacerdoti, David

    2017-01-07

    Measurement of portal pressure is pivotal in the evaluation of patients with liver cirrhosis. The measurement of the hepatic venous pressure gradient represents the reference method by which portal pressure is estimated. However, it is an invasive procedure that requires significant hospital resources, including experienced staff, and is associated with considerable cost. Non-invasive methods that can be reliably used to estimate the presence and the degree of portal hypertension are urgently needed in clinical practice. Biochemical and morphological parameters have been proposed for this purpose, but have shown disappointing results overall. Splanchnic Doppler ultrasonography and the analysis of microbubble contrast agent kinetics with contrast-enhanced ultrasonography have shown better accuracy for the evaluation of patients with portal hypertension. A key advancement in the non-invasive evaluation of portal hypertension has been the introduction in clinical practice of methods able to measure stiffness in the liver, as well as stiffness/congestion in the spleen. According to the data published to date, it appears to be possible to rule out clinically significant portal hypertension in patients with cirrhosis ( i.e ., hepatic venous pressure gradient ≥ 10 mmHg) with a level of clinically-acceptable accuracy by combining measurements of liver stiffness and spleen stiffness along with Doppler ultrasound evaluation. It is probable that the combination of these methods may also allow for the identification of patients with the most serious degree of portal hypertension, and ongoing research is helping to ensure progress in this field.

  5. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    International Nuclear Information System (INIS)

    Wu, Tian-Tian; Li, Hu-Cheng; Zheng, Fang; Ao, Guo-Kun; Lin, Hu; Li, Wei-Min

    2016-01-01

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

  6. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tian-Tian, E-mail: matthewwu1979@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Li, Hu-Cheng, E-mail: hucheng-li-surgery@126.com [The 307th Hospital of PLA, General Surgery Department (China); Zheng, Fang, E-mail: fang-zheng-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Ao, Guo-Kun, E-mail: guokun-ao-radiology@126.com; Lin, Hu, E-mail: hu-lin-radiology@126.com [The 309th Hospital of PLA, Radiology Department (China); Li, Wei-Min, E-mail: weimin-li-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China)

    2016-07-15

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

  7. Endovascular management for significant iatrogenic portal vein bleeding.

    Science.gov (United States)

    Kim, Jong Woo; Shin, Ji Hoon; Park, Jonathan K; Yoon, Hyun-Ki; Ko, Gi-Young; Gwon, Dong Il; Kim, Jin Hyoung; Sung, Kyu-Bo

    2017-11-01

    Background Despite conservative treatment, hemorrhage from an intrahepatic branch of the portal vein can cause hemodynamic instability requiring urgent intervention. Purpose To retrospectively report the outcomes of hemodynamically significant portal vein bleeding after endovascular management. Material and Methods During a period of 15 years, four patients (2 men, 2 women; median age, 70.5 years) underwent angiography and embolization for iatrogenic portal vein bleeding. Causes of hemorrhage, angiographic findings, endovascular treatment, and complications were reported. Results Portal vein bleeding occurred after percutaneous liver biopsy (n = 2), percutaneous radiofrequency ablation (n = 1), and percutaneous cholecystostomy (n = 1). The median time interval between angiography and percutaneous procedure was 5 h (range, 4-240 h). Common hepatic angiograms including indirect mesenteric portograms showed active portal vein bleeding into the peritoneal cavity with (n = 1) or without (n = 2) an arterioportal (AP) fistula, and portal vein pseudoaneurysm alone with an AP fistula (n = 1). Successful transcatheter arterial embolization (n = 2) or percutaneous transhepatic portal vein embolization (n = 2) was performed. Embolic materials were n-butyl cyanoacrylate alone (n = 2) or in combination with gelatin sponge particles and coils (n = 2). There were no major treatment-related complications or patient mortality within 30 days. Conclusion Patients with symptomatic or life-threatening portal vein bleeding following liver-penetrating procedures can successfully be managed with embolization.

  8. Prospective clinical evaluation of an electronic portal imaging device

    International Nuclear Information System (INIS)

    Michalski, Jeff M.; Graham, Mary V.; Bosch, Walter R.; Wong, John; Gerber, Russell L.; Cheng, Abel; Tinger, Alfred; Valicenti, Richard K.

    1996-01-01

    ). Features that were identified that prevented the technologists from recognizing more errors online include poor image quality inherent to the portal imaging device used in this study, artifacts on the portal images related to table supports, and small field size lacking sufficient anatomical detail to detect FPEs. Furthermore, tools to objectively evaluate a portal image for the presence of field placement error were lacking. These include magnification factor corrections between the simulation of portal image, online measurement tools, image enhancement tools, and image registration algorithms. Conclusion: The use of an electronic portal imaging device in our clinic has been implemented without a significant increase in patient treatment time. Online intervention and correction of patient positioning occurred rarely, despite FPEs of > 10 mm being present in more than 10% of the treated fields. A significant reduction in FPEs exceeding 10 mm was made in the group of patients receiving pelvic radiotherapy. It is likely that this improvement was made secondarily to a decrease in systematic error and not because of online interventions. More significant improvements in portal image quality and the availability of online image registration tools are required before substantial improvements can be made in patient positioning with online portal imaging

  9. The macrophage activation marker sCD163 combined with markers of the Enhanced Liver Fibrosis (ELF) score predicts clinically significant portal hypertension in patients with cirrhosis

    DEFF Research Database (Denmark)

    Sandahl, T D; McGrail, R; Møller, H J

    2016-01-01

    BACKGROUND: Noninvasive identification of significant portal hypertension in patients with cirrhosis is needed in hepatology practice. AIM: To investigate whether the combination of sCD163 as a hepatic inflammation marker and the fibrosis markers of the Enhanced Liver Fibrosis score (ELF) can...... predict portal hypertension in patients with cirrhosis. METHODS: We measured sCD163 and the ELF components (hyaluronic acid, tissue inhibitor of metalloproteinase-1 and procollagen-III aminopeptide) in two separate cohorts of cirrhosis patients that underwent hepatic vein catheterisation. To test...... the predictive accuracy we developed a CD163-fibrosis portal hypertension score in an estimation cohort (n = 80) and validated the score in an independent cohort (n = 80). A HVPG ≥10 mmHg was considered clinically significant. RESULTS: Both sCD163 and the ELF components increased in a stepwise manner...

  10. Preduodenal portal vein: its surgical significance.

    Science.gov (United States)

    Makey, D A; Bowen, J C

    1978-11-01

    Preduodenal portal vein is a rare anatomical variant which may be one of many anomalies in the neonate with duodenal "atresia." Preduodenal portal vein also may be an occasional finding in an adult undergoing biliary, gastric, or pancreatic surgery. Awareness and recognition of the anomaly are essential for the avoidance of injury during such operations. We report here a symptomless patient whose preduodenal portal vein was discovered at cholecystectomy.

  11. Use of a web portal among adult clinic patients seen for type 2 diabetes mellitus.

    Science.gov (United States)

    Coughlin, Steven S; Heboyan, Vahé; Williams, Lovoria B; Hatzigeorgiou, Christos

    2018-01-01

    To determine the number of adult clinic patients seen for type 2 diabetes mellitus (T2DM) at an academic medical center and to examine characteristics of those who had or had not registered for a web portal. Electronic records were reviewed to identify web portal registration by patients treated for T2DM by age, sex, race and Hispanic ethnicity, and service (General Internal Medicine, Endocrinology). A total of 1,401 patients with T2DM were seen in General Internal Medicine and Endocrinology outpatient clinics. Less than one third (32%) had registered for the web portal. Women were more likely to have registered for the web portal than men [odds ratio (OR) =1.25; 95% CI, 0.99-1.57; Pweb portal, along with those who were 56 to 60 and >66 years of age. In multivariate analysis, a statistically significant association was observed between web portal registration and General Internal Medicine clinic vs . Endocrinology clinic (OR =2.96, P18-25 years, male sex (adjusted OR =0.71, P=0.006), and Black race (OR =0.33, P<0.001). Additional research is needed to identify portal design features that improve glycemic control and interventions that will increase use of patient portals, especially among Black patients with T2DM and those with low health literacy or computer literacy.

  12. Noncirrhotic portal hypertension.

    Science.gov (United States)

    Da, Ben L; Koh, Christopher; Heller, Theo

    2018-05-01

    Noncirrhotic portal hypertension represents a heterogeneous group of liver disorders that is characterized by portal hypertension in the absence of cirrhosis. The purpose of this review is to serve as a guide on how to approach a patient with noncirrhotic portal hypertension with a focus on recent developments. Recent studies pertaining to noncirrhotic portal hypertension have investigated aetiological causes, mechanisms of disease, noninvasive diagnostic modalities, clinical characteristics in the paediatric population and novel treatment targets. Noncirrhotic portal hypertension is an underappreciated clinical entity that can be difficult to diagnosis without a healthy suspicion. Diagnosis then relies on a comprehensive understanding of the causes and clinical manifestations of this disease, as well as a careful interpretation of the liver biopsy. Noninvasive approaches to diagnosis may play a significant role moving forward in this disease. Treatment in NCPH remains largely targeted at the individual sequalae of portal hypertension.

  13. Clinical evaluation of per-rectal portal scintigraphy in patients with liver cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Yoneyama, Keiichiro; Kamata, Hideaki; Sakamoto, Osamu; Ogasawara, Hiroshi; Takeuchi, Haruo; Onuki, Makoto; Taguchi, Susumu; Hatta, Yoshio

    1986-09-01

    Hepatic blood flow and portal shunts were clinically studied with Tc-99m per-rectal portal scintigraphy in 51 patients with liver cirrhosis. RI time-activity curves of the liver and heart were used to define 3 patterns: type I = RI activity was more intense in the liver than in the heart, type II = more intense in the liver at one min and that in the heart at 15 min, or type III = less intense in the liver than in the heart. Four (8 %) of the patients had type 1, 22 (43 %) type II, and 25 (49 %) type III. Esophageal varices and splenomegaly were significantly associated with type III (p < 0.01). Regarding laboratory findings indicative of the impairment of liver function, there was no significant difference among the three types of RI activity. Indocyamine green tolerance test showed significantly higher R15 in the group with type III than in the other two groups (p < 0.05). Three other patients with idiopathic portal hypertension without liver function disturbance had type III. Per-rectal portal scintigraphy will be of help as a noninvasive tool for reflecting not only portal shunts but also hepatic blood flow and for predicting the severity of liver cirrhosis. (Namekawa, K.).

  14. Portal venous stent placement for treatment of portal hypertension caused by benign main portal vein stenosis.

    Science.gov (United States)

    Shan, Hong; Xiao, Xiang-Sheng; Huang, Ming-Sheng; Ouyang, Qiang; Jiang, Zai-Bo

    2005-06-07

    To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Portal vein stents were implanted in six patients with benign main portal vein stenosis (inflammatory stenosis in three cases, postprocedure of liver transplantation in another three cases). Changes in portal vein pressure, portal vein patency, relative clinical symptoms, complications, and survival were evaluated. Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in six patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3+/-4.7) cm H(2)O to (18.0+/-1.9) cm H(2)O. The portal blood flow restored and the symptoms caused by portal hypertension were eliminated. There were no severe procedure-related complications. The patients were followed up for 1-48 mo. The portal vein remained patent during follow-up. All patients survived except for one patient who died of other complications of liver transplantation. Percutaneous portal vein stent placement for the treatment of portal hypertension caused by benign main portal vein stenosis is safe and effective.

  15. Impact of health portal enrollment with email reminders on adherence to clinic appointments: a pilot study.

    Science.gov (United States)

    Horvath, Monica; Levy, Janet; L'Engle, Pete; Carlson, Boyd; Ahmad, Asif; Ferranti, Jeffrey

    2011-05-26

    Internet portal technologies that provide access to portions of electronic health records have the potential to revolutionize patients' involvement in their care. However, relatively few descriptions of the demographic characteristics of portal enrollees or of the effects of portal technology on quality outcomes exist. This study examined data from patients who attended one of seven Duke Medicine clinics and who were offered the option of enrolling in and using the Duke Medicine HealthView portal (HVP). The HVP allows patients to manage details of their appointment scheduling and provides automated email appointment reminders in addition to the telephone and mail reminders that all patients receive. Our objective was to test whether portal enrollment with an email reminder functionality is significantly related to decreases in rates of appointment "no-shows," which are known to impair clinic operational efficiency. Appointment activity during a 1-year period was examined for all patients attending one of seven Duke Medicine clinics. Patients were categorized as portal enrollees or as nonusers either by their status at time of appointment or at the end of the 1-year period. Demographic characteristics and no-show rates among these groups were compared. A binomial logistic regression model was constructed to measure the adjusted impact of HVP enrollment on no-show rates, given confounding factors. To demonstrate the effect of HVP use over time, monthly no-show rates were calculated for patient appointment keeping and contrasted between preportal and postportal deployment periods. Across seven clinics, 58,942 patients, 15.7% (9239/58,942) of whom were portal enrollees, scheduled 198,199 appointments with an overall no-show rate of 9.9% (19,668/198,199). We found that HVP enrollees were significantly more likely to be female, white, and privately insured compared with nonusers. Bivariate no-show rate differences between portal enrollment groups varied widely according

  16. Obliterative portal venopathy without portal hypertension: an underestimated condition.

    Science.gov (United States)

    Guido, Maria; Sarcognato, Samantha; Sonzogni, Aurelio; Lucà, Maria Grazia; Senzolo, Marco; Fagiuoli, Stefano; Ferrarese, Alberto; Pizzi, Marco; Giacomelli, Luciano; Colloredo, Guido

    2016-03-01

    Obliterative portal venopathy without portal hypertension has been described by a single study in a limited number of patients, thus very little is known about this clinical condition. This study aimed to investigate the prevalence of obliterative portal venopathy and its clinical-pathological correlations in patients with cryptogenic chronic liver test abnormalities without clinical signs of portal hypertension. We analysed 482 liver biopsies from adults with non-cirrhotic cryptogenic chronic liver disorders and without any clinical signs of portal hypertension, consecutively enrolled in a 5-year period. Twenty cases of idiopathic non-cirrhotic portal hypertension diagnosed in the same period, were included for comparison. Histological findings were matched with clinical and laboratory features. Obliterative portal venopathy was identified in 94 (19.5%) of 482 subjects and in all 20 cases of idiopathic non-cirrhotic portal hypertension: both groups shared the entire spectrum of histological changes described in the latter condition. The prevalence of incomplete fibrous septa and nodular regenerative hyperplasia was higher in the biopsies of idiopathic non-cirrhotic portal hypertension (P = 0.006 and P = 0.002), a possible hint of a more advanced stage of the disease. The two groups also shared several clinical laboratory features, including a similar liver function test profile, concomitant prothrombotic conditions and extrahepatic autoimmune disorders. Obliterative portal venopathy occurs in a substantial proportion of patients with unexplained chronic abnormal liver function tests without portal hypertension. The clinical-pathological profile of these subjects suggests that they may be in an early (non-symptomatic) stage of idiopathic non-cirrhotic portal hypertension. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Diagnostic significance of hepatic venography and retrograde portography in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Fukunaga, Masaki

    1987-07-01

    In this series, we studied about diagnostic significance of hepatic venography and retrograde portography in portal hypertension by using stepwise discriminant analysis. The accuracy rate of the discrimination was 95 % in liver cirrhosis (LC), 86 % in B' type LC, 83 % in primary biliary cirrhosis (PBC) and 57 % in idiopathic portal hypertension (IPH). The difficulty in differential diagnosis of IPH from PBC was due to similarity of hepatic vascular changes in both diseases. Next we studied about the relationship between venographic findings and the causes of LC. The size of regenerated nodule in alcoholic LC was significantly smaller than the others, so venographic findings were different from others. It was concluded that hepatic venography was useful examination for differential diagnosis in portal hypertension, and was effective for considering about the causes of LC.

  18. Diagnostic significance of hepatic venography and retrograde portography in portal hypertension

    International Nuclear Information System (INIS)

    Fukunaga, Masaki

    1987-01-01

    In this series, we studied about diagnostic significance of hepatic venography and retrograde portography in portal hypertension by using stepwise discriminant analysis. The accuracy rate of the discrimination was 95 % in liver cirrhosis (LC), 86 % in B' type LC, 83 % in primary biliary cirrhosis (PBC) and 57 % in idiopathic portal hypertension (IPH). The difficulty in differential diagnosis of IPH from PBC was due to similarity of hepatic vascular changes in both diseases. Next we studied about the relationship between venographic findings and the causes of LC. The size of regenerated nodule in alcoholic LC was significantly smaller than the others, so venographic findings were different from others. It was concluded that hepatic venography was useful examination for differential diagnosis in portal hypertension, and was effective for considering about the causes of LC. (author)

  19. Portal vein thrombosis; risk factors, clinical presentation and treatment

    DEFF Research Database (Denmark)

    Sogaard, Kirstine K; Astrup, Lone B; Vilstrup, Hendrik

    2007-01-01

    and treatment of portal vein thrombosis in a single-centre. METHODS: Sixty-seven patients were identified in the electronic records from 1992 to 2005. All data were obtained from the patient records. RESULTS: One or more risk factors (e.g. prothrombotic disorder or abdominal inflammation) were present in 87......BACKGROUND: Portal vein thrombosis (PVT) is increasingly frequently being diagnosed, but systematic descriptions of the natural history and clinical handling of the condition are sparse. The aim of this retrospective study was to describe risk factors, clinical presentation, complications...

  20. Clinical usefulness of Tc-99M pertechnetate per-rectal portal scintigraphy in evaluation the severity of portal hypertension in cirrhotic patients

    International Nuclear Information System (INIS)

    Namwongprom, S.; Ekmahachai, M.; Boonyaprapa, S.; Vilasdechanon, N.; Taya, P.; Chankaew, N.; Chitapanarux, T.

    2004-01-01

    Objectives: Variceal hemorrhage is a potentially life-threatening complication in cirrhotic patients. Identification of patients at high risk for bleeding is particularly important. The aim of this study was to determine the clinical usefulness of per-rectal portal scintigraphy in evaluation the severity of portal hypertension in cirrhotic patients in terms of correlation between cirrhosis and classic indicators of hepatic functional reserve and identifying the difference of the portal shunt index (PSI) of the bleeding esophageal varices group and non-bleeding esophageal varices group. Material and methods: Portal circulations in 15 healthy volunteer's and in 67 patients with cirrhosis were evaluated by Tc-99m pertechnetate per-rectal p. ortal scintigraphy. Tc-99m pertechnetate (550 MBq) was instilled into the upper rectum, and dynamic images were taken. Radioactivity curves of the liver and the heart were generated sequentially. Through the analysis of these curves, the PSI was determined by calculating the ratio of counts of the liver to counts of the heart integrated for 24 seconds immediately after the appearance of the liver time-activity curve. Results: The results, expressed as PSI were: 13.63 +/- 6.28 % in healthy subjects and 66.32+/-22.80 % in cirrhotic patients. Of these, the PSIs were 56036 +/- 27.14 % in 31 cirrhotic patients without esophageal varices, and 74.89 +/- 13.62 % in 36 cirrhotic patients with esophageal varices. The PSI was significantly lower in cirrhotic patients without bleeding esophageal vances (BEV) than those with BEV (p=0.001). The PSI calculated with this method was correlated with the serum albumin, the serum bilirubin and the Child-Pugh's score. Conclusion: The Tc-99m pertechnetate per-rectal portal scintigraphy has clinical usefulness as a relatively non-invasive method of choice for quantitative evaluating the severity of portal hypertension in cirrhotic patients. (authors)

  1. Patient-Centered Personal Health Record and Portal Implementation Toolkit for Ambulatory Clinics: A Feasibility Study.

    Science.gov (United States)

    Nahm, Eun-Shim; Diblasi, Catherine; Gonzales, Eva; Silver, Kristi; Zhu, Shijun; Sagherian, Knar; Kongs, Katherine

    2017-04-01

    Personal health records and patient portals have been shown to be effective in managing chronic illnesses. Despite recent nationwide implementation efforts, the personal health record and patient portal adoption rates among patients are low, and the lack of support for patients using the programs remains a critical gap in most implementation processes. In this study, we implemented the Patient-Centered Personal Health Record and Patient Portal Implementation Toolkit in a large diabetes/endocrinology center and assessed its preliminary impact on personal health record and patient portal knowledge, self-efficacy, patient-provider communication, and adherence to treatment plans. Patient-Centered Personal Health Record and Patient Portal Implementation Toolkit is composed of Patient-Centered Personal Health Record and Patient Portal Implementation Toolkit-General, clinic-level resources for clinicians, staff, and patients, and Patient-Centered Personal Health Record and Patient Portal Implementation Toolkit Plus, an optional 4-week online resource program for patients ("MyHealthPortal"). First, Patient-Centered Personal Health Record and Patient Portal Implementation Toolkit-General was implemented, and all clinicians and staff were educated about the center's personal health record and patient portal. Then general patient education was initiated, while a randomized controlled trial was conducted to test the preliminary effects of "MyHealthPortal" using a small sample (n = 74) with three observations (baseline and 4 and 12 weeks). The intervention group showed significantly greater improvement than the control group in patient-provider communication at 4 weeks (t56 = 3.00, P = .004). For other variables, the intervention group tended to show greater improvement; however, the differences were not significant. In this preliminary study, Patient-Centered Personal Health Record and Patient Portal Implementation Toolkit showed potential for filling the gap in the current

  2. Morphological and biomechanical remodeling of the hepatic portal vein in a swine model of portal hypertension.

    Science.gov (United States)

    He, Xi-Ju; Huang, Tie-Zhu; Wang, Pei-Jun; Peng, Xing-Chun; Li, Wen-Chun; Wang, Jun; Tang, Jie; Feng, Na; Yu, Ming-Hua

    2012-02-01

    To obtain the morphological and biomechanical remodeling of portal veins in swine with portal hypertension (PHT), so as to provide some mechanical references and theoretical basis for clinical practice about PHT. Twenty white pigs were used in this study, 14 of them were subjected to both carbon tetrachloride- and pentobarbital-containing diet to induce experimental liver cirrhosis and PHT, and the remaining animals served as the normal controls. The morphological remodeling of portal veins was observed. Endothelial nitric oxide synthase expression profile in the vessel wall was assessed at both mRNA and protein level. The biomechanical changes of the hepatic portal veins were evaluated through assessing the following indicators: the incremental elastic modulus, pressure-strain elastic modulus, volume elastic modulus, and the incremental compliance. The swine PHT model was successfully established. The percentages for the microstructural components and the histological data significantly changed in the experimental group. Endothelial nitric oxide synthase expression was significantly downregulated in the portal veins of the experimental group. Three incremental elastic moduli (the incremental elastic modulus, pressure-strain elastic modulus, and volume elastic modulus) of the portal veins from PHT animals were significantly larger than those of the controls (P portal vein decreased. Our study suggests that the morphological and biomechanical properties of swine hepatic portal veins change significantly during the PHT process, which may play a critical role in the development of PHT and serve as potential therapeutic targets during clinical practice. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  3. Association between portal vein pressure drop gradient after transjugular intrahepatic portosystemic shunt and clinical prognosis

    Directory of Open Access Journals (Sweden)

    XU Zhengguo

    2016-12-01

    Full Text Available ObjectiveTo investigate the association between portal vein pressure drop gradient in patients with cirrhotic portal hypertension treated by transjugular intrahepatic portosystemic shunt (TIPS and clinical prognosis, as well as the ideal range of portal vein pressure drop. MethodsA total of 58 patients who underwent TIPS in Xinqiao Hospital of Third Military Medical University from November 2013 to December 2015 were enrolled. All the patients underwent TIPS and embolization of the gastric coronary vein and the short gastric veins, and the change intervals of portal vein pressure gradient were monitored. The follow-up time ranged from 3 days to 2 years, and the association of portal vein pressure drop gradient with postoperative liver function, splenic function, rebleeding rate, hepatic encephalopathy, and portal hypertensive gastrointestinal diseases was analyzed. The paired t-test was used for comparison of parameters before and after treatment. ResultsThe patients had a significant reduction in liver function on day 3 after surgery. At 2 month after surgery, the levels of TBil was rised and had significant changes[(49.81±27.82μmol/L vs (31.64±17.67 μmol/L,t=5.372,P<0.001]. At 6 months after surgery, red blood cell count and platelet count had no significant changes,but,white blood cell count was reduced[(3.79±1.37)×109/L vs (4.57±2.24×109/L,t=2.835,P=0.006]. There was a 23% reduction in portal vein pressure after surgery (from 30.62±3.56 mmHg before surgery to 21.21±2.90 mmHg after surgery, t=23.318,P<0.001. All the patients had varying degrees of relief of gastrointestinal symptoms associated with portal vein hypertension, such as abdominal distension, poor appetite, and diarrhea. Of all patients, none experienced in-stent restenosis or occlusion and 13 experienced hepatic encephalopathy after surgery, which tended to occur at the time when postoperative portal vein pressure was reduced to 14.7-25.7 mmHg, i

  4. Clinical Trial Electronic Portals for Expedited Safety Reporting: Recommendations from the Clinical Trials Transformation Initiative Investigational New Drug Safety Advancement Project.

    Science.gov (United States)

    Perez, Raymond P; Finnigan, Shanda; Patel, Krupa; Whitney, Shanell; Forrest, Annemarie

    2016-12-15

    Use of electronic clinical trial portals has increased in recent years to assist with sponsor-investigator communication, safety reporting, and clinical trial management. Electronic portals can help reduce time and costs associated with processing paperwork and add security measures; however, there is a lack of information on clinical trial investigative staff's perceived challenges and benefits of using portals. The Clinical Trials Transformation Initiative (CTTI) sought to (1) identify challenges to investigator receipt and management of investigational new drug (IND) safety reports at oncologic investigative sites and coordinating centers and (2) facilitate adoption of best practices for communicating and managing IND safety reports using electronic portals. CTTI, a public-private partnership to improve the conduct of clinical trials, distributed surveys and conducted interviews in an opinion-gathering effort to record investigator and research staff views on electronic portals in the context of the new safety reporting requirements described in the US Food and Drug Administration's final rule (Code of Federal Regulations Title 21 Section 312). The project focused on receipt, management, and review of safety reports as opposed to the reporting of adverse events. The top challenge investigators and staff identified in using individual sponsor portals was remembering several complex individual passwords to access each site. Also, certain tasks are time-consuming (eg, downloading reports) due to slow sites or difficulties associated with particular operating systems or software. To improve user experiences, respondents suggested that portals function independently of browsers and operating systems, have intuitive interfaces with easy navigation, and incorporate additional features that would allow users to filter, search, and batch safety reports. Results indicate that an ideal system for sharing expedited IND safety information is through a central portal used by

  5. The effect of partial portal decompression on portal blood flow and effective hepatic blood flow in man: a prospective study.

    Science.gov (United States)

    Rosemurgy, A S; McAllister, E W; Godellas, C V; Goode, S E; Albrink, M H; Fabri, P J

    1995-12-01

    With the advent of transjugular intrahepatic porta-systemic stent shunt and the wider application of the surgically placed small diameter prosthetic H-graft portacaval shunt (HGPCS), partial portal decompression in the treatment of portal hypertension has received increased attention. The clinical results supporting the use of partial portal decompression are its low incidence of variceal rehemorrhage due to decreased portal pressures and its low rate of hepatic failure, possibly due to maintenance of blood flow to the liver. Surprisingly, nothing is known about changes in portal hemodynamics and effective hepatic blood flow following partial portal decompression. To prospectively evaluate changes in portal hemodynamics and effective hepatic blood flow brought about by partial portal decompression, the following were determined in seven patients undergoing HGPCS: intraoperative pre- and postshunt portal vein pressures and portal vein-inferior vena cava pressure gradients, intraoperative pre- and postshunt portal vein flow, and pre- and postoperative effective hepatic blood flow. With HGPCS, portal vein pressures and portal vein-inferior vena cava pressure gradients decreased significantly, although portal pressures remained above normal. In contrast to the significant decreases in portal pressures, portal vein blood flow and effective hepatic blood flow do not decrease significantly. Changes in portal vein pressures and portal vein-inferior vena cava pressure gradients are great when compared to changes in portal vein flow and effective hepatic blood flow. Reduction of portal hypertension with concomitant maintenance of hepatic blood flow may explain why hepatic dysfunction is avoided following partial portal decompression.

  6. Treatment of portal hypertension caused by benign main portal vein stenosis with endovascular stent

    International Nuclear Information System (INIS)

    Huang Mingsheng; Shan Hong; Jiang Zaibo; Guan Shouhai; Zhu Kangshun; Li Zhengran; Zhou Yubin; He Bingjun

    2004-01-01

    Objective: To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Methods: Portal vein stents were implanted in 6 patients with benign main portal vein stenosis (inflammatory stenosis in 3 cases, postprocedure of liver transplantation in another 3 cases). The change of portal vein pressure, the patency of portal vein, relative clinical symptoms, complications, and survival were evaluated. Results: Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in all 6 patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3 ± 4.7) cm H 2 O (1 cm H 2 O=0.098 kPa) to (18.0 ± 1.9) cm H 2 O (P<0.001). The portal blood flow was restored, and the symptoms caused by portal hypertension were eliminated. There was no severe procedure-related complication. Follow-up time was from 5 to 36 months. The portal vein remained patent during the follow-up. All patients survived except one patient who died of other complications of liver transplantation. Conclusion: Percutaneous portal vein stent placement for the treatment of the benign main portal vein stenosis is safe and effective. (authors)

  7. CT portal venography manifestations of portal collateral circulation in patients with portal hypertension due to cirrhosis

    International Nuclear Information System (INIS)

    Ni Ming; Lv Weifu; Deng Kexue

    2009-01-01

    Objective: To analyze CT portal venography (CTPV) manifestations of portal collateral circulation in patients with cirrhosis by using a 16-detector row spiral CT scanner. Methods: CTPV was performed in 36 patients with portal hypertension due to cirrhosis, the diagnosis was proved by clinical data, hepatic function findings and imaging signs. By using post-processing reconstruction technique, 3D images of portal venous system and portal collateral circulation were obtained. Results: CTPV images displayed the portal venous system and its collateral circulation stereoscopically. Of 36 patients, left gastric varices were seen in 29(80.6%), lower esophageal varices in 18(50.0%), short gastric or posterior gastric varices in 15(41.7%), paraesophageal varices in 9(25.0%), gastro-renal or splenorenal shunts in 8(22.2%), spongelike transformation of portal vein in 7(19.4%), paraumbilical and abdominal wall varices in 6(16.7%), congenital cavernous in 6(16.7%) and paravertebral venous shunts in 4(11.1%). Conclusion: CTPV can well display the site, extent and severity of the portal collateral circulation in patients with portal hypertension due to cirrhosis,which is of great clinical importance for judging the patient's condition, for selecting therapeutic protocols and for estimating prognosis. (authors)

  8. Clinical quantitative study of therapeutic effect of partial splenic embolization (PSE) on portal vein hemodynamics

    International Nuclear Information System (INIS)

    Li Zhengran; Shan Hong; Zhu Kangshun; Jiang Zaibo; Guan Shouhai; Huang Mingsheng

    2002-01-01

    Objective: To research the changes of blood flow and pressure of the portal vein at both pre-and post-PSE. Methods: The blood flows of the portal vein (PV), splenic vein (SV), and superior mesentery vein (SMV) were measured by using color Doppler in 31 cases with clinically proved hepatic cirrhosis and hypersplenism at both pre- and post-PSE. The pressure of the portal vein and its branches was measured by percutaneous and trans-spleen portal venous catheterization, respectively both pre- and post-embolization in 11 cases of them. Results: The blood flow of PV, SV and SMV decreased significantly in all 31 cases after PSE (P < 0.05). The decreased degrees of blood flow of both PV and SV after PSE were positively related to the embolization degree (r = 0.589, P = 0.002 for PV; r= 0.862, P < 0.001 for SV). In 11 cases whose embolization degrees were more than 60%, the pressure of PV, SV and SMV decreased significantly after embolization (P<0.001). The decrease degree was (22.2 +- 5.8)%, (28.5 +- 1.7)% and (19.5 +- 8.1)%, respectively. The decreased degrees of pressure of both PV and SV after PSE were also positively related to the embolization degree (r = 0.645, P = 0.032 for PV; r = 0.687, P = 0.020 for SV). Conclusion: The embolization degree ranged from 60% to 80% may ameliorate peripheral blood WBC and PLT count, significantly decrease the blood flow and depress the pressure of portal vein, and relieve esophageal and gastric varices

  9. Percutaneous transsplenic catheterization of portal vein: technique and clinical application

    International Nuclear Information System (INIS)

    Zhu Kangshun; Huang Mingsheng; Pang Pengfei; Zhou Bin; Xu Changmo; Qian Jiesheng; Li Zhengran; Jiang Zaibo; Shan Hong

    2010-01-01

    Objective: To evaluate the feasibility of percutaneous transsplenic portal vein catheterization (PTSPC). Methods: Thirty patients with portal hypertension underwent gastroesophageal variceal embolization via PTSPC route, 2 of which simultaneously underwent portal vein stenting. This study included the patients with portal venous obstruction (tumor embolus or thrombus) or the patients with serious liver atrophy caused by liver cirrhosis. The patients who had severe coagulation insufficiency (with prothrombin time > 20 s) were excluded. Of the 30 patients, 17 had primary hepatocellular carcinoma with main portal venous tumor embolus, 13 had cirrhosis with severe liver atrophy and (or)slight or moderate ascite. Before this study, all of 30 patients had a history of variceal bleeding, and 16 patients had a normal coagulation level, 10 patients had a mildly prolonged prothrombin time (14-17 s), 4 patients had a moderately prolonged prothrombin time (18-20 s). All of 30 patients underwent upper abdomen CT enhanced scanning before this procedure, and the site, direction, and depth of splenic vein branch puncture were decided by CT images. The technology of PTSPC, procedure-related complications, and its clinical application were retrospectively analyzed. Results: PTSPC was performed successfully in 28 of 30 patients. Two cases failed because of a small intrasplenic vein. Procedure-related complications occurred in 6 patients (20.0%), which had decrease of hemoglobin concentration (15-50 g/L). Four of them needed blood transfusion. In the six patients, one patient (3.3%) with abdominal cavity hemorrhage had a serious drop of blood pressure 2 hours after procedure, whose clinical symptoms were relieved after four units of packed RBC and a great quantity of fluid were transfused. Twenty-eight patients whose PTSPC were successfully performed underwent variceal embolization, 2 of them were placed with portal vein covered stents. During a median follow-up period of 6 months

  10. Pharmacology Portal: An Open Database for Clinical Pharmacologic Laboratory Services.

    Science.gov (United States)

    Karlsen Bjånes, Tormod; Mjåset Hjertø, Espen; Lønne, Lars; Aronsen, Lena; Andsnes Berg, Jon; Bergan, Stein; Otto Berg-Hansen, Grim; Bernard, Jean-Paul; Larsen Burns, Margrete; Toralf Fosen, Jan; Frost, Joachim; Hilberg, Thor; Krabseth, Hege-Merete; Kvan, Elena; Narum, Sigrid; Austgulen Westin, Andreas

    2016-01-01

    More than 50 Norwegian public and private laboratories provide one or more analyses for therapeutic drug monitoring or testing for drugs of abuse. Practices differ among laboratories, and analytical repertoires can change rapidly as new substances become available for analysis. The Pharmacology Portal was developed to provide an overview of these activities and to standardize the practices and terminology among laboratories. The Pharmacology Portal is a modern dynamic web database comprising all available analyses within therapeutic drug monitoring and testing for drugs of abuse in Norway. Content can be retrieved by using the search engine or by scrolling through substance lists. The core content is a substance registry updated by a national editorial board of experts within the field of clinical pharmacology. This ensures quality and consistency regarding substance terminologies and classification. All laboratories publish their own repertoires in a user-friendly workflow, adding laboratory-specific details to the core information in the substance registry. The user management system ensures that laboratories are restricted from editing content in the database core or in repertoires within other laboratory subpages. The portal is for nonprofit use, and has been fully funded by the Norwegian Medical Association, the Norwegian Society of Clinical Pharmacology, and the 8 largest pharmacologic institutions in Norway. The database server runs an open-source content management system that ensures flexibility with respect to further development projects, including the potential expansion of the Pharmacology Portal to other countries. Copyright © 2016 Elsevier HS Journals, Inc. All rights reserved.

  11. Clinical significance of circumportal pancreas, a rare congenital anomaly, in pancreatectomy.

    Science.gov (United States)

    Ohtsuka, Takao; Mori, Yasuhisa; Ishigami, Kousei; Fujimoto, Takaaki; Miyasaka, Yoshihiro; Nakata, Kohei; Ohuchida, Kenoki; Nagai, Eishi; Oda, Yoshinao; Shimizu, Shuji; Nakamura, Masafumi

    2017-08-01

    Circumportal pancreas is a rare congenital pancreatic anomaly. The aim of this study was to clarify the clinical characteristics of patients with circumportal pancreases undergoing pancreatectomy. The medical records of 508 patients who underwent pancreatectomy were retrospectively reviewed. The prevalence of circumportal pancreas and related anatomical variations were assessed. Surgical procedures and postoperative outcomes were compared in patients with and without circumportal pancreas. Circumportal pancreas was observed in 9 of the 508 patients (1.7%). In all nine patients, the portal vein was completely encircled by the pancreatic parenchyma above the level of the splenoportal junction, and the main pancreatic duct ran dorsal to the portal vein. The rate of variant hepatic artery did not differ significantly in patients with and without circumportal pancreas. Pancreatic fistula developed more frequently in patients with than without circumportal pancreas (44% vs. 14%, p = 0.03), but other clinical parameters did not differ significantly in these two groups. Despite being rare, circumportal pancreas may increase the risk of postoperative pancreatic fistula in patients undergoing pancreatectomy. However, a prospective, large-cohort study is necessary to determine the real incidence of relevant anatomical variations and the definitive clinical significance of this rare anomaly. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Technical and clinical evaluation of an improved-contrast screen-film combination for radiation therapy portal localization imaging

    International Nuclear Information System (INIS)

    Haus, Arthur G.; Dickerson, Robert E.; Huff, Kenneth E.; Monte, Suzanne; Schlager, Barbara A.; Atanas, Meri; Matloubieh, Ahmad

    1996-01-01

    Purpose/Objective: A problem with conventional radiation therapy portal images is low image contrast, due in part to the low attenuation of the exposing radiation by the anatomical parts being imaged and the contrast capabilities of the film or screen-film combination. The purpose of this study was to design, develop and clinically evaluate a new screen-film combination for portal localization imaging which provides significantly higher contrast and therefore improved image quality. Materials and Methods: Comparison phantom and clinical images were made at two radiation oncology facilities with the new prototype screen-film combination and a commercial screen-film combination currently used for portal localization imaging. All images were made with linear accelerators at 6MV. Sensitometric data was also obtained. The prototype combination features a 1.0mm copper front screen plus front and back gadolinium oxysulfide fluorescent intensifying screens and a very-slow-speed film having inherently high contrast. The film emulsion layers are coated on a 7 mil Estar base which allows processing in a conventional rapid process film processor. For this combination, the film is exposed primarily by light from the intensifying screens. The current, commercially available screen-film combination was a Kodak X-Omatic L Radiation Therapy Cassette with a 1.0mm copper front screen and a 0.25mm lead back screen and Kodak X-Omat RP film in ready pack envelope. With this combination, the film emulsion is exposed by electrons generated in the metal screens. All films were processed in a Kodak M35A X-Omat processor. Radiation oncologists reviewed the phantom and clinical images. Results: Sensitometric data indicate that the film contrast (average gradient) of the new prototype combination is approximately 4 times higher than the conventional commercially available combination. Phantom and clinical comparisons at St. Mary Cancer Center, Langhorne PA. and the Daisy Marquis Jones

  13. Scintiphotosplenoportography in patients with portal hypertension

    International Nuclear Information System (INIS)

    Aijaz, A.

    1990-01-01

    Scintiphotosplenoportograpy (SSP) was performed in five normals and 25 patients with portal hypertension using Tc-99m tin colloid. 12 patients were cirrhotic and 13 had idiopathic portal hypertension (IPH). Analogue and fast frame dynamic studies were performed and subsequently processed. Intra hepatic shunt index in cirrhotics was significantly different from the IPH group. Extra hepatic shunt index, however, was not significantly different in the two groups but was related more to the severity of the disease process. Spleno hepatic and spleno cardiac transit times were significantly lower cirrhotics as compared to the IPH group. We conclude that SSP is a technically simple, rapid and a much less invasive method of visualizing the portal circulatory system and assessing the portal haemo dynamics. it also provides clinically important measure of shunted blood nd allows for the quantification of circulatory time from spleen to liver and heart. (author)

  14. TRANSTIBIAL VERSUS ANTEROMEDIAL PORTAL TECHNIQUES IN ACL RECONSTRUCTION

    Directory of Open Access Journals (Sweden)

    Luiz Gabriel Betoni Guglielmetti

    Full Text Available Abstract Introduction: Although the results of anterior cruciate ligament (ACL reconstruction are well documented in many studies, with good to excellent outcomes in most cases, some issues like tunnel positioning are still discussed and studied. Objective: To compare the objective and subjective clinical outcomes of ACL reconstruction using the transtibial and anteromedial portal techniques. Methods: Prospective randomized study of 80 patients undergoing anterior cruciate ligament reconstruction by the same surgeon, with 40 patients operated by the transtibial technique and 40 by anteromedial portal technique. The patients, 34 in the transtibial group and 37 in the anteromedial portal group (nine dropouts, were reassessed during a 2-year follow-up period. The clinical assessment consisted of physical examination, KT-1000TM evaluation, Lysholm score, and objective and subjective International Knee Documentation Committee - IKDC scores. Results: Regarding the Lachman and pivot shift tests, we observed more cases of instability in the transtibial group, but with no statistical significance (p=0.300 and p=0.634, respectively. Regarding the anterior drawer test, the groups presented similar results (p=0.977. Regarding KT-1000TM evaluation, the mean results were 1.44 for the transtibial group and 1.23 for the anteromedial portal group, with no statistical significance (p=0.548. We separated the objective IKDC scores into two groups: Group 1, IKDC A, and Group 2, IKDC B, C, or D, with no statistical significance (p=0.208. Concerning the Lysholm score, the transtibial group had a mean score of 91.32, and the anteromedial portal group had a mean score of 92.81. The mean subjective IKDC scores were 90.65 for the transtibial group and 92.65 for the anteromedial portal group. Three re-ruptures were encountered in the transtibial group and three in the anteromedial portal group. Conclusions: There were no significant differences in the subjective and

  15. Pathophysiology of Portal Hypertension and Its Clinical Links

    Science.gov (United States)

    Seo, Yeon Seok; Shah, Vijay H

    2011-01-01

    Portal hypertension is a major cause of morbidity and mortality in patients with liver cirrhosis. Intrahepatic vascular resistance due to architectural distortion and intrahepatic vasoconstriction, increased portal blood flow due to splanchnic vasodilatation, and development of collateral circulation have been considered as major factors for the development of portal hypertension. Recently, sinusoidal remodeling and angiogenesis have been focused as potential etiologic factors and various researchers have tried to improve portal hypertension by modulating these new targets. This article reviews potential new treatments in the context of portal hypertension pathophysiology concepts. PMID:25755320

  16. Use of a web portal by adult patients with pre-diabetes and type 2 diabetes mellitus seen in a family medicine outpatient clinic.

    Science.gov (United States)

    Coughlin, Steven S; Heboyan, Vahé; Young, Lufei; De Leo, Gianluca; Wilkins, Thad

    2018-05-01

    There has been increasing interest in the use of web portals by patients with type 2 diabetes mellitus (T2DM). Studies of web portal use by patients with pre-diabetes have not been reported. To plan studies of web portal use by adult clinic patients seen for pre-diabetes and T2DM at an academic medical center, we examined characteristics of those who had or had not registered for a web portal. Electronic records were reviewed to identify web portal registration by patients treated for pre-diabetes or T2DM by age, sex, race and ethnicity. A total of 866 patients with pre-diabetes and 2,376 patients with T2DM were seen in a family medicine outpatient clinic. About 41.5% of patients with pre-diabetes and 34.7% of those with T2DM had registered for the web portal. In logistic regression analysis, web portal registration among patients with T2DM was significantly associated with age 41-45 years, and with Hispanic ethnicity. Similar results were obtained for pre-diabetes except that the positive association with age 41-45 years and inverse association with Hispanic ethnicity were not statistically significant. Among patients with pre-diabetes or T2DM, Black men and Black women were less likely to have registered than their white counterparts. Patients who were aged 18-25 and >65 years were less likely to have registered for the web portal than those 26-65 years. Additional research is needed to identify portal design features that improve health outcomes for patients with pre-diabetes and T2DM and interventions that will increase use of patient portals by pre-diabetic and diabetic patients, especially among Black patients and older patients.

  17. Portal hypertensiv gastropati

    DEFF Research Database (Denmark)

    Brinch, K; Møller, S; Henriksen, Jens Henrik Sahl

    1995-01-01

    Portal hypertensive gastropathy (PHG) as defined by congestive changes in the gastric mucosa owing to increased portal pressure, was first described about ten years ago. Whereas definition and grading of severity are still under debate, there is general agreement that PHG is a new clinical entity....... PHG is present in 50-80% of patients with liver cirrhosis. PHG is a major cause of upper gastrointestinal bleeding in patients with portal hypertension (25-90% depending on severity). Presence of portal hypertension is a prerequisite for the development of PHG, and reduction of portal pressure...

  18. Clinical implications of portal hemodynamics after small-diameter portacaval H graft

    International Nuclear Information System (INIS)

    Sarfeh, I.J.; Rypins, E.B.; Fardi, M.; Conroy, R.M.; Mason, G.R.; Lyons, K.P.

    1984-01-01

    To assess the role of portal hemodynamics in the development of postshunt encephalopathy, we studied 19 patients after small-diameter portacaval H grafting (SD-PCHG). We used contrast studies as well as technetium-labeled macroaggregated albumin injected into the portal vein to assess direction of portal flow. We then quantitated the mesenteric fraction of flow perfusing the liver by injecting macroaggregated albumin into a peripheral mesenteric vein tributary. We found that none of seven patients with prograde flow by both scintigraphy and angiography developed postoperative encephalopathy, but the incidence was 58% in the remaining patients (p . 0.02). The fraction of mesenteric flow perfusing the liver after SD-PCHG was 12% +/- 4%, but this did not significantly correlate with encephalopathy rates. We conclude that after SD-PCHG, prograde portal flow minimizes encephalopathy rates. Although encephalopathy occurs in patients with predominantly reversed flow, a subgroup of patients with reversed flow remain without symptoms. The absolute fraction of mesenteric flow perfusing the liver has less influence on encephalopathy rates than has direction of portal flow. This study identifies a complex relationship between portal hemodynamics and encephalopathy

  19. Integrative Analysis of Complex Cancer Genomics and Clinical Profiles Using the cBioPortal

    Science.gov (United States)

    Gao, Jianjiong; Aksoy, Bülent Arman; Dogrusoz, Ugur; Dresdner, Gideon; Gross, Benjamin; Sumer, S. Onur; Sun, Yichao; Jacobsen, Anders; Sinha, Rileen; Larsson, Erik; Cerami, Ethan; Sander, Chris; Schultz, Nikolaus

    2014-01-01

    The cBioPortal for Cancer Genomics (http://cbioportal.org) provides a Web resource for exploring, visualizing, and analyzing multidimensional cancer genomics data. The portal reduces molecular profiling data from cancer tissues and cell lines into readily understandable genetic, epigenetic, gene expression, and proteomic events. The query interface combined with customized data storage enables researchers to interactively explore genetic alterations across samples, genes, and pathways and, when available in the underlying data, to link these to clinical outcomes. The portal provides graphical summaries of gene-level data from multiple platforms, network visualization and analysis, survival analysis, patient-centric queries, and software programmatic access. The intuitive Web interface of the portal makes complex cancer genomics profiles accessible to researchers and clinicians without requiring bioinformatics expertise, thus facilitating biological discoveries. Here, we provide a practical guide to the analysis and visualization features of the cBioPortal for Cancer Genomics. PMID:23550210

  20. Modified Anterolateral Portals in Elbow Arthroscopy: A Cadaveric Study on Safety.

    Science.gov (United States)

    Thon, Stephen; Gold, Peter; Rush, Lane; O'Brien, Michael J; Savoie, Felix H

    2017-11-01

    To evaluate the proximity to the radial nerve on cadaveric specimens of 2 modified anterolateral portals used for elbow arthroscopy. Ten fresh cadaveric elbow specimens were prepared. Four-millimeter Steinman pins were inserted into 3 anterolateral portal sites in relation to the lateral epicondyle: (1) the standard distal anterolateral portal, (2) a modified direct anterolateral portal, and (3) a modified proximal anterolateral portal. These were defined as follows: direct portals 2 cm directly anterior to the lateral epicondyle, and proximal portals 2 cm proximal and 2 cm directly anterior to the lateral epicondyle. Each elbow was then dissected to reveal the course of the radial nerve. Digital photographs were taken of each specimen, and the distance from the Steinman pin to the radial nerve was measured. The modified proximal anterolateral and direct anterolateral portals were found to be a statistically significant distance from the radial nerve compare to the distal portal site (P = .011 and P = .0011, respectively). No significant difference was found in the proximity of the radial nerve between the modified proximal and direct anterolateral portals (P = .25). Inadequate imaging was found at a single portal site for the proximal site; 9 specimens were used for analysis of this portal with 10 complete specimens for the other 2 sites. In cadaveric analysis, both the modified proximal and direct lateral portals provide adequate distance from the radial nerve and may be safe for clinical use. In this study, the distal anterolateral portal was in close proximity of the radial nerve and may result in iatrogenic injury in the clinical setting. This is a cadaveric analysis of 2 modified portal locations at the anterolateral elbow for use in elbow arthroscopy. Further clinical studies are needed prior to determining their absolute safety in comparison to previously identified portal sites. Copyright © 2017 Arthroscopy Association of North America. Published by

  1. Origins of Portal Hypertension in Nonalcoholic Fatty Liver Disease.

    Science.gov (United States)

    Baffy, Gyorgy

    2018-03-01

    Nonalcoholic fatty liver disease (NAFLD) advanced to cirrhosis is often complicated by clinically significant portal hypertension, which is primarily caused by increased intrahepatic vascular resistance. Liver fibrosis has been identified as a critical determinant of this process. However, there is evidence that portal venous pressure may begin to rise in the earliest stages of NAFLD when fibrosis is far less advanced or absent. The biological and clinical significance of these early changes in sinusoidal homeostasis remains unclear. Experimental and human observations indicate that sinusoidal space restriction due to hepatocellular lipid accumulation and ballooning may impair sinusoidal flow and generate shear stress, increasingly disrupting sinusoidal microcirculation. Sinusoidal endothelial cells, hepatic stellate cells, and Kupffer cells are key partners of hepatocytes affected by NAFLD in promoting endothelial dysfunction through enhanced contractility, capillarization, adhesion and entrapment of blood cells, extracellular matrix deposition, and neovascularization. These biomechanical and rheological changes are aggravated by a dysfunctional gut-liver axis and splanchnic vasoregulation, culminating in fibrosis and clinically significant portal hypertension. We may speculate that increased portal venous pressure is an essential element of the pathogenesis across the entire spectrum of NAFLD. Improved methods of noninvasive portal venous pressure monitoring will hopefully give new insights into the pathobiology of NAFLD and help efforts to identify patients at increased risk for adverse outcomes. In addition, novel drug candidates targeting reversible components of aberrant sinusoidal circulation may prevent progression in NAFLD.

  2. Pediatric portal hypertension

    Science.gov (United States)

    Vogel, Clarissa Barbon

    2017-01-01

    Abstract: Pediatric portal hypertension management is a team approach between the patient, the patient's family, the primary caregiver, and specialty providers. Evidence-based practice guidelines have not been established in pediatrics. This article serves as a review for the primary care NP in the management of pediatric portal hypertension, discussing the etiology, pathophysiology, and clinical presentation of pediatric portal hypertension, diagnostic tests, and treatment and management options. PMID:28406835

  3. Novel treatment options for portal hypertension

    Science.gov (United States)

    Laleman, Wim

    2017-01-01

    Abstract Portal hypertension is most frequently associated with cirrhosis and is a major driver for associated complications, such as variceal bleeding, ascites or hepatic encephalopathy. As such, clinically significant portal hypertension forms the prelude to decompensation and impacts significantly on the prognosis of patients with liver cirrhosis. At present, non-selective β-blockers, vasopressin analogues and somatostatin analogues are the mainstay of treatment but these strategies are far from satisfactory and only target splanchnic hyperemia. In contrast, safe and reliable strategies to reduce the increased intrahepatic resistance in cirrhotic patients still represent a pending issue. In recent years, several preclinical and clinical trials have focused on this latter component and other therapeutic avenues. In this review, we highlight novel data in this context and address potentially interesting therapeutic options for the future. PMID:28533907

  4. Advances in the treatment of portal hypertension in cirrhosis.

    Science.gov (United States)

    Kimer, N; Wiese, S; Mo, S; Møller, S; Bendtsen, F

    2016-08-01

    Non-selective beta-blockers and handling of esophageal varices has been key elements in the treatment of portal hypertension in recent decades. Liver vein catheterization has been essential in diagnosis and monitoring of portal hypertension, but ongoing needs for noninvasive tools has led to research in areas of both biomarkers, and transient elastography, which displays promising results in discerning clinically significant portal hypertension. Novel research into the areas of hepatic stellate cell function and the dynamic components of portal hypertension has revealed promising areas of treatment modalities, targeting intestinal decontamination, angiogenesis, inflammation and oxidative stress. Future studies may reveal if these initiatives lead to developments of new drugs for treatment of portal hypertension.

  5. Advances in the treatment of portal hypertension in cirrhosis

    DEFF Research Database (Denmark)

    Kimer, Nina; Wiese, S; Mo, S S

    2016-01-01

    Non-selective beta-blockers and handling of esophageal varices has been key elements in the treatment of portal hypertension in recent decades. Liver vein catheterization has been essential in diagnosis and monitoring of portal hypertension, but ongoing needs for noninvasive tools has led...... to research in areas of both biomarkers, and transient elastography, which displays promising results in discerning clinically significant portal hypertension. Novel research into the areas of hepatic stellate cell function and the dynamic components of portal hypertension has revealed promising areas...... of treatment modalities, targeting intestinal decontamination, angiogenesis, inflammation and oxidative stress. Future studies may reveal if these initiatives lead to developments of new drugs for treatment of portal hypertension....

  6. Impact of hepatitis C oral therapy in portal hypertension.

    Science.gov (United States)

    Libânio, Diogo; Marinho, Rui Tato

    2017-07-14

    Chronic hepatitis C is a leading cause of morbidity and mortality, mainly related to fibrosis/cirrhosis and portal hypertension. Direct antiviral agents are highly effective and safe and can now cure > 90% of the patients. Sustained viral response (SVR) after interferon-based regimens has been associated with improvement in liver function, fibrosis and portal hypertension in a significant proportion of patients, although a point of no return seems to exist from which viral elimination is no longer capable of preventing portal hypertension progression and liver decompensation. Indeed, although SVR is associated with improvement of hepatic venous pressure gradients and therefore a decreased risk of de novo esophageal varices, several studies show that viral clearance does not eliminate the risk of variceal progression, liver decompensation and death in patients with pre-established portal hypertension. Although evidence about the effects of direct antiviral agents (DAAs) on clinically significant outcomes is still scarce and with short follow-up, DAAs can decrease the burden of the disease if patients are timely treated before significant fibrosis and portal hypertension develops. Studies with longer follow-up are waited to establish the real magnitude of hepatitis C treatment on portal hypertension. Future studies should also focus on predictors of portal hypertension resolution since it can influence management and avoid unnecessary monitoring.

  7. Idiopathic noncirrhotic portal hypertension: current perspectives.

    Science.gov (United States)

    Riggio, Oliviero; Gioia, Stefania; Pentassuglio, Ilaria; Nicoletti, Valeria; Valente, Michele; d'Amati, Giulia

    2016-01-01

    The term idiopathic noncirrhotic portal hypertension (INCPH) has been recently proposed to replace terms, such as hepatoportal sclerosis, idiopathic portal hypertension, incomplete septal cirrhosis, and nodular regenerative hyperplasia, used to describe patients with a hepatic presinusoidal cause of portal hypertension of unknown etiology, characterized by features of portal hypertension (esophageal varices, nonmalignant ascites, porto-venous collaterals), splenomegaly, patent portal, and hepatic veins and no clinical and histological signs of cirrhosis. Physicians should learn to look for this condition in a number of clinical settings, including cryptogenic cirrhosis, a disease known to be associated with INCPH, drug administration, and even chronic alterations in liver function tests. Once INCPH is clinically suspected, liver histology becomes mandatory for the correct diagnosis. However, pathologists should be familiar with the histological features of INCPH, especially in cases in which histology is not only requested to exclude liver cirrhosis.

  8. Pancreatic pseudocyst-portal vein fistula: Serial imaging and clinical follow-up from pseudocyst to fistula

    Energy Technology Data Exchange (ETDEWEB)

    Jee, Keun Nahn [Dept. of Radiology, Dankook University Hospital, Dankook University College of Medicine, Cheonan (Korea, Republic of)

    2015-03-15

    Pancreatic pseudocyst-portal vein fistula is an extremely rare complication of pancreatitis. Only 18 such cases have been previously reported in the medical literature. However, a serial process from pancreatic pseudocyst to fistula formation has not been described. The serial clinical and radiological findings in a 52-year-old chronic alcoholic male patient with fistula between pancreatic pseudocyst and main portal vein are presented.

  9. Portal annular pancreas: a systematic review of a clinical challenge.

    Science.gov (United States)

    Harnoss, Jonathan M; Harnoss, Julian C; Diener, Markus K; Contin, Pietro; Ulrich, Alexis B; Büchler, Markus W; Schmitz-Winnenthal, Friedrich H

    2014-10-01

    Portal annular pancreas (PAP) is an asymptomatic congenital pancreas anomaly, in which portal and/or mesenteric veins are encased by pancreas tissue. The aim of the study was to determine the role of PAP in pancreatic surgery as well as its management and potential complication, specifically, postoperative pancreatic fistula (POPF).On the basis of a case report, the MEDLINE and ISI Web of Science databases were systematically reviewed up to September 2012. All articles describing a case of PAP were considered.In summary, 21 studies with 59 cases were included. The overall prevalence of PAP was 2.4% and the patients' mean (SD) age was 55.9 (16.2) years. The POPF rate in patients with PAP (12 pancreaticoduodenectomies and 3 distal pancreatectomies) was 46.7% (in accordance with the definition of the International Study Group of Pancreatic Surgery).Portal annular pancreas is a quite unattended pancreatic variant with high prevalence and therefore still remains a clinical challenge to avoid postoperative complications. To decrease the risk for POPF, attentive preoperative diagnostics should also focus on PAP. In pancreaticoduodenectomy, a shift of the resection plane to the pancreas tail should be considered; in extensive pancreatectomy, coverage of the pancreatic remnant by the falciform ligament could be a treatment option.

  10. Idiopathic Noncirrhotic Portal Hypertension: An Appraisal

    Science.gov (United States)

    Lee, Hwajeong; Rehman, Aseeb Ur; Fiel, M. Isabel

    2016-01-01

    Idiopathic noncirrhotic portal hypertension is a poorly defined clinical condition of unknown etiology. Patients present with signs and symptoms of portal hypertension without evidence of cirrhosis. The disease course appears to be indolent and benign with an overall better outcome than cirrhosis, as long as the complications of portal hypertension are properly managed. This condition has been recognized in different parts of the world in diverse ethnic groups with variable risk factors, resulting in numerous terminologies and lack of standardized diagnostic criteria. Therefore, although the diagnosis of idiopathic noncirrhotic portal hypertension requires clinical exclusion of other conditions that can cause portal hypertension and histopathologic confirmation, this entity is under-recognized clinically as well as pathologically. Recent studies have demonstrated that variable histopathologic entities with different terms likely represent a histologic spectrum of a single entity of which obliterative portal venopathy might be an underlying pathogenesis. This perception calls for standardization of the nomenclature and formulation of widely accepted diagnostic criteria, which will facilitate easier recognition of this disorder and will highlight awareness of this entity. PMID:26563701

  11. The transjugular portosystemic stent shunt (TIPSS) as an intervention in clinical complication of portal hypertension

    International Nuclear Information System (INIS)

    Thalhammer, A.; Jacobi, V.; Schwarz, W.; Balzer, J.; Abolmaali, N.; Vogl, T.J.

    2001-01-01

    Most frequent complications in patients with liver cirrhosis are due to portal hypertension. Beside ascites circumvent vessles formate with vasodilatation. Due to counterregulation a secondary hyperaldosteronism develops with release of vasocontrictive agents. If conservative and endoscopic methods fail, indication for building a portosystemic shunt is given. The TIPSS procedure is less invasive than the surgical method of Warren-Shunt, so the radiological intervention has replaced surgery. Reducing the portal pressure by the shunt, the clinical complications change for the better. Still problems are defined as hepatic encephalopathy and right ventricular heart failure. Regular follow up investigations have to be performed to detect complications in the shunt. Using regular clinical and radiological check up TIPSS is of clinical benefit with good long term results. (orig.) [de

  12. Portal vein stenting for delayed jejunal varix bleeding associated with portal venous occlusion after hepatoiliary and pancreatic surgery

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Dong Ho; Park, Kwang Bo; Cho, Sung Ki; Park, Hong Suk; Shin, Sung Wook; Choo, Sung Wook; Do, Young Soo; Choo, In Wook; Choi, Dong Wook [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-09-15

    The study aimed to describe portal stenting for postoperative portal occlusion with delayed (≥ 3 months) variceal bleeding in the afferent jejunal loop. Eleven consecutive patients (age range, 2–79 years; eight men and three women) who underwent portal stenting between April 2009 and December 2015 were included in the study. Preoperative medical history and the postoperative clinical course were reviewed. Characteristics of portal occlusion and details of procedures were also investigated. Technical success, treatment efficacy (defined as disappearance of jejunal varix on follow-up CT), and clinical success were analyzed. Primary stent patency rate was plotted using the Kaplan-Meier method. All patients underwent hepatobiliary-pancreatic cancer surgery except two children with liver transplantation for biliary atresia. Portal occlusion was caused by benign postoperative change (n = 6) and local tumor recurrence (n = 5). Variceal bleeding occurred at 27 months (4 to 72 months) and portal stenting was performed at 37 months (4 to 121 months), on average, postoperatively. Technical success, treatment efficacy, and clinical success rates were 90.9, 100, and 81.8%, respectively. The primary patency rate of portal stent was 88.9% during the mean follow-up period of 9 months. Neither procedure-related complication nor mortality occurred. Interventional portal stenting is an effective treatment for delayed jejunal variceal bleeding due to portal occlusion after hepatobiliary-pancreatic surgery.

  13. Portal vein stenting for delayed jejunal varix bleeding associated with portal venous occlusion after hepatoiliary and pancreatic surgery

    International Nuclear Information System (INIS)

    Hyun, Dong Ho; Park, Kwang Bo; Cho, Sung Ki; Park, Hong Suk; Shin, Sung Wook; Choo, Sung Wook; Do, Young Soo; Choo, In Wook; Choi, Dong Wook

    2017-01-01

    The study aimed to describe portal stenting for postoperative portal occlusion with delayed (≥ 3 months) variceal bleeding in the afferent jejunal loop. Eleven consecutive patients (age range, 2–79 years; eight men and three women) who underwent portal stenting between April 2009 and December 2015 were included in the study. Preoperative medical history and the postoperative clinical course were reviewed. Characteristics of portal occlusion and details of procedures were also investigated. Technical success, treatment efficacy (defined as disappearance of jejunal varix on follow-up CT), and clinical success were analyzed. Primary stent patency rate was plotted using the Kaplan-Meier method. All patients underwent hepatobiliary-pancreatic cancer surgery except two children with liver transplantation for biliary atresia. Portal occlusion was caused by benign postoperative change (n = 6) and local tumor recurrence (n = 5). Variceal bleeding occurred at 27 months (4 to 72 months) and portal stenting was performed at 37 months (4 to 121 months), on average, postoperatively. Technical success, treatment efficacy, and clinical success rates were 90.9, 100, and 81.8%, respectively. The primary patency rate of portal stent was 88.9% during the mean follow-up period of 9 months. Neither procedure-related complication nor mortality occurred. Interventional portal stenting is an effective treatment for delayed jejunal variceal bleeding due to portal occlusion after hepatobiliary-pancreatic surgery

  14. Duplex sonography in portal hypertension

    International Nuclear Information System (INIS)

    Kwon, Hyuk Po; Jang, J. C.; Park, B. H.

    1990-01-01

    We measure the diameter and blood velocity of the portal vein in 50 patients with cirrhosis of the liver and 40 healthy subjects, and calculated cross sectional area, mean blood flow velocity, blood flow volume and congestion index. In patients with cirrhosis of the liver, the cross sectional area of the portal vein was significantly increased: the mean blood flow volume was significantly reduced; the blood flow volume was significantly increased; the congestion index of the portal vein was significantly increased. Duples sonography may play an important role in the diagnosis of portal hypertension

  15. Decision-making models in the analysis of portal films: a clinical pilot study

    International Nuclear Information System (INIS)

    See, A.; Johansen, J.; Hamilton, C.; Bydder, S.A.; Hawkins, J.; Roff, M.; Denham, J.; Kron, T.

    2000-01-01

    Portal films continue to play an important role in the verification of radiotherapy treatment. There is still some discussion, however, as to what action should be taken after a port film has shown a radiation field deviation from the prescribed volume. It was the aim of the present pilot study to investigate the performance of three decision-making models ('Amsterdam', 'Quebec' and 'Newcastle') and an expert panel basing their decision on intuition rather than formal rules after portal film acquisition in a clinical setting. Portal films were acquired on every day during the first week of treatment for five head and neck and five prostate cancer patients (diagnostic phase). If required, the field position was modified according to our normal practice following the recommendation of the expert panel. In order to analyse the results of the models, however, additional port films were taken in the following 3 treatment weeks with the patient moved as required by the different models (intervention phase). The portal films were taken over 4 consecutive days, positioning the patient according to each of the different models on one day each. None of the models diagnosed a field misplacement in the head and neck patients, while the 'Amsterdam' and 'Quebec' models predicted a move in one prostate patient. The 'Newcastle' model, which is based on Hotelling's T 2 statistic, proved to be more sensitive and diagnosed a systematic displacement for three prostate patients. The intervention phase confirmed the diagnosis of the model, even if the three portal films taken with the patient position adjusted as required by the model proved to be insufficient to demonstrate an improvement. The 'Newcastle' model does not rely on assumptions about the random movement of patients and requires five portal films before a decision can be reached. This approach lends itself well to incorporation into electronic portal imaging 'packages', where repeated image acquisitions present no logistical

  16. Biology of portal hypertension.

    Science.gov (United States)

    McConnell, Matthew; Iwakiri, Yasuko

    2018-02-01

    Portal hypertension develops as a result of increased intrahepatic vascular resistance often caused by chronic liver disease that leads to structural distortion by fibrosis, microvascular thrombosis, dysfunction of liver sinusoidal endothelial cells (LSECs), and hepatic stellate cell (HSC) activation. While the basic mechanisms of LSEC and HSC dysregulation have been extensively studied, the role of microvascular thrombosis and platelet function in the pathogenesis of portal hypertension remains to be clearly characterized. As a secondary event, portal hypertension results in splanchnic and systemic arterial vasodilation, leading to the development of a hyperdynamic circulatory syndrome and subsequently to clinically devastating complications including gastroesophageal varices and variceal hemorrhage, hepatic encephalopathy from the formation of portosystemic shunts, ascites, and renal failure due to the hepatorenal syndrome. This review article discusses: (1) mechanisms of sinusoidal portal hypertension, focusing on HSC and LSEC biology, pathological angiogenesis, and the role of microvascular thrombosis and platelets, (2) the mesenteric vasculature in portal hypertension, and (3) future directions for vascular biology research in portal hypertension.

  17. Predictive model of portal venous system thrombosis in cirrhotic portal hypertensive patients after splenectomy

    OpenAIRE

    He, Shasha; He, Fangping

    2015-01-01

    Objective: This study is to investigate the risk factors of portal venous system thrombosis (PVT) in patients with cirrhotic portal hypertension after splenectomy and to establish a Logistic regression prediction model. Methods: A total of 119 patients with cirrhotic portal hypertension were enrolled. Their clinical data was retrospectively analyzed. They were divided into PVT group (n = 18) and non-PVT group (n = 101). One-way analysis and multivariate Logistic regression analysis were perfo...

  18. First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane dose

    International Nuclear Information System (INIS)

    Boellaard, R.; Herk, M. van; Uiterwaal, H.; Mijnheer, B.

    1998-01-01

    Background and purpose: Recently, algorithms have been developed to derive the patient dose from portal dose measurements using a liquid-filled electronic portal imaging device. These algorithms have already been validated for several phantom geometries irradiated under clinical conditions. It is the aim of the present study to investigate the applicability of a liquid-filled electronic portal imaging device in combination with these algorithms for two-dimensional midplane dose verification in clinical practice. Measurements and methods: Portal dose images were obtained during several patient treatments under routine clinical conditions. Measurements were performed to verify the midplane dose during radiotherapy of larynx cancer with 4 MV beams, breast and lung cancer with 8 MV beams and prostate cancer with both 8 and 18 MV beams. Midplane doses, determined from portal dose measurements and analyzed with our algorithms, were compared with midplane doses calculated with our three-dimensional (3D) treatment planning system (TPS). Results: For the larynx treatment the measured 2D midplane dose agreed within 2.0% with TPS calculations in most parts of the field. Larger differences were found in a small region below the skin due to the absence of electron equilibrium, which is not taken into account in our portal dose analysis. For breast irradiations the measured midplane dose showed a homogeneous distribution in the AP direction in the axial plane, while high dose regions were observed in the cranial and caudal part of the breast. Portal dose measurements and TPS calculations agreed within 2.5% for most of the prostate and lung irradiations. For a few of the prostate and lung treatments larger local differences were found due to differences between the actual patient anatomy and the planning CT data, e.g. as a result of variable gas filling in the rectum and anatomical changes in the lung. Conclusions: Portal dose measurements with a liquid-filled electronic portal

  19. Doppler US evaluation of the hypertensive portal system

    International Nuclear Information System (INIS)

    Needleman, L.; Kurtz, A.B.; Bezzi, M.; Rifkin, M.D.; Pasto, M.E.; Pennell, R.G.; Baltarowich, O.H.; Goldberg, B.B.

    1986-01-01

    In patients with known portal hypertension, pulsed Doppler US was used for qualitative and directional evaluation of flow in the portal venous system and collateral vessels. Most patients had normal hepatopetal flow. Doppler US revealed the following abnormal blood flow patterns: hepatofugal portal flow, bidirectional portal flow, intrahepatic portal shunting, flow in portasystemic collaterals, and hepatic vein obstruction. Doppler US can provide important clinical information in the evaluation of portal hypertension

  20. Elastography methods for the non-invasive assessment of portal hypertension.

    Science.gov (United States)

    Roccarina, Davide; Rosselli, Matteo; Genesca, Joan; Tsochatzis, Emmanuel A

    2018-02-01

    The gold standard to assess the presence and severity of portal hypertension remains the hepatic vein pressure gradient, however the recent development of non-invasive assessment using elastography techniques offers valuable alternatives. In this review, we discuss the diagnostic accuracy and utility of such techniques in patients with portal hypertension due to cirrhosis. Areas covered: A literature search focused on liver and spleen stiffness measurement with different elastographic techniques for the assessment of the presence and severity of portal hypertension and oesophageal varices in people with chronic liver disease. The combination of elastography with parameters such as platelet count and spleen size is also discussed. Expert commentary: Non-invasive assessment of liver fibrosis and portal hypertension is a validated tool for the diagnosis and follow-up of patients. Baveno VI recommended the combination of transient elastography and platelet count for ruling out varices needing treatment in patients with compensated advanced chronic liver disease. Assessment of aetiology specific cut-offs for ruling in and ruling out clinically significant portal hypertension is an unmet clinical need. The incorporation of spleen stiffness measurements in non-invasive algorithms using validated software and improved measuring scales might enhance the non-invasive diagnosis of portal hypertension in the next 5 years.

  1. Clinical application of endovascular stent-graft in the treatment of portal stenosis of cancerous thrombus

    International Nuclear Information System (INIS)

    Jiang Zaibo; Huang Mingsheng; Wang Jing; Li Zhengran; Qian Jiesheng; Guang Shouhai; Zhu Kangshun; Shan Hong; Zhang Xiongjun

    2007-01-01

    Objective: To explore the approach and early effects of endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Methods: Six cases with portal vein stenosis of cancerous thrombus, which caused by primary hepatic carcinoma (5 cases) and cholangiocarcinoma (1 case) and the severity of stenosis showed on contrast enhanced CT were more than 75% or occluded, were performed percutaneous transhepatic or transsplenic portography. FLUENCY TM endovascular stent-graft (10 mm diameter) was placed at the position of stenosis after gastroesophageal varices embolization. Portal pressure was measured pre- and post-deployment. Results: Stents were successfully placed in all patients. The average portal pressure decreased from 50.7 em H 2 O (1 cm H 2 O0.098 kPa) to 41.3 cm H 2 O after endovascular stent-graft deployment. The restenosis were found in 2 cases after one month. Haematemesis and refractory ascites appeared in one case respectively, the other 4 cases showed no significant symptoms above caused by portal hypertension. Conclusion: It is safe and feasible for endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Selecting the suitable indications, the symptoms of portal hypertension can be controlled effectively. (authors)

  2. Idiopathic non-cirrhotic portal hypertension

    Directory of Open Access Journals (Sweden)

    CHEN Jie

    2013-07-01

    Full Text Available The pathogenesis of idiopathic non-cirrhotic portal hypertension (INCPH remains unknown and the disease is diagnosed by the absence of recognized clinical indicators of cirrhosis and of any other known etiologies of portal hypertension. To promote understanding of this disease, a comprehensive overview of potential etiologies, clinical manifestations, histopathological features, methods of diagnosis and potential differential diagnoses, and outcome of clinical management is presented in this review. In particular, we discuss the findings from INCPH studies and their implications in regards to each of the above-mentioned categories. For example, associations with various comorbidities have suggested a possible immune system component to INCPH development and/or progression. In addition, the common clinical characteristics of patients upon presentation can not only help to recognize disease suspects but may also provide insights into the pathogenesis and prognosis. Finally, prognosis following the various intervention strategies appears to depend mainly on severity of the portal hypertension, as well as its various accompanying complications.

  3. An automated portal verification system for the tangential breast portal field

    International Nuclear Information System (INIS)

    Yin, F.-F.; Lai, W.; Chen, C. W.; Nelson, D. F.

    1995-01-01

    Purpose/Objective: In order to ensure the treatment is delivered as planned, a portal image is acquired in the accelerator and is compared to the reference image. At present, this comparison is performed by radiation oncologists based on the manually-identified features, which is both time-consuming and potentially error-prone. With the introduction of various electronic portal imaging devices, real-time patient positioning correction is becoming clinically feasible to replace time-delayed analysis using films. However, this procedure requires present of radiation oncologists during patient treatment which is not cost-effective and practically not realistic. Therefore, the efficiency and quality of radiation therapy could be substantially improved if this procedure can be automated. The purpose of this study is to develop a fully computerized verification system for the radiation therapy of breast cancer for which a similar treatment setup is generally employed. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature correlation between reference and portal images, and quantitative evaluation of patient setup. In this study, a matrix liquid ion-chamber EPID was used to acquire digital portal images which is directly attached to Varian CL2100C accelerator. For effective use of computation memory, the 12-bit gray levels in original portal images were quantized to form a range of 8-bit gray levels. A typical breast portal image includes three important components: breast and lung tissues in the treatment field, air space within the treatment field, and non-irradiated region. A hierarchical region processing technique was developed to separate these regions sequentially. The inherent hierarchical features were formulated based on different radiation attenuation for different regions as: treatment field edge -- breast skin line -- chest wall. Initially, a combination of a Canny edge detector and a constrained

  4. Portal hypertensive gastropathy: A systematic review of the pathophysiology, clinical presentation, natural history and therapy

    Science.gov (United States)

    Gjeorgjievski, Mihajlo; Cappell, Mitchell S

    2016-01-01

    AIM: To describe the pathophysiology, clinical presentation, natural history, and therapy of portal hypertensive gastropathy (PHG) based on a systematic literature review. METHODS: Computerized search of the literature was performed via PubMed using the following medical subject headings or keywords: “portal” and “gastropathy”; or “portal” and “hypertensive”; or “congestive” and “gastropathy”; or “congestive” and “gastroenteropathy”. The following criteria were applied for study inclusion: Publication in peer-reviewed journals, and publication since 1980. Articles were independently evaluated by each author and selected for inclusion by consensus after discussion based on the following criteria: Well-designed, prospective trials; recent studies; large study populations; and study emphasis on PHG. RESULTS: PHG is diagnosed by characteristic endoscopic findings of small polygonal areas of variable erythema surrounded by a pale, reticular border in a mosaic pattern in the gastric fundus/body in a patient with cirrhotic or non-cirrhotic portal hypertension. Histologic findings include capillary and venule dilatation, congestion, and tortuosity, without vascular fibrin thrombi or inflammatory cells in gastric submucosa. PHG is differentiated from gastric antral vascular ectasia by a different endoscopic appearance. The etiology of PHG is inadequately understood. Portal hypertension is necessary but insufficient to develop PHG because many patients have portal hypertension without PHG. PHG increases in frequency with more severe portal hypertension, advanced liver disease, longer liver disease duration, presence of esophageal varices, and endoscopic variceal obliteration. PHG pathogenesis is related to a hyperdynamic circulation, induced by portal hypertension, characterized by increased intrahepatic resistance to flow, increased splanchnic flow, increased total gastric flow, and most likely decreased gastric mucosal flow. Gastric mucosa

  5. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1996-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine geometric errors quantitatively; discuss some of the ways that portal imaging has been incorporated into routine clinical practice; describe quality assurance procedures for these devices, and discuss the use of portal imaging devices for dosimetry applications. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. However, the task is not nearly as straight-forward as it sounds. One problem

  6. Patients' Experiences with and Attitudes towards a Diabetes Patient Web Portal.

    Science.gov (United States)

    Ronda, Maaike C M; Dijkhorst-Oei, Lioe-Ting; Rutten, Guy E H M

    2015-01-01

    A diabetes patient web portal allows patients to access their personal health record and may improve diabetes outcomes; however, patients' adoption is slow. We aimed to get insight into patients' experiences with a web portal to understand how the portal is being used, how patients perceive the content of the portal and to assess whether redesign of the portal might be needed. A survey among 1500 patients with type 1 and type 2 diabetes with a login to a patient portal. 62 primary care practices and one outpatient hospital clinic, using a combined patient portal. We compared patients who requested a login but never used it or once ('early quitters') with patients who used it at least two times ('persistent users'). 632 patients (42.1%) returned the questionnaire. Their mean age was 59.7 years, 63.1% was male and 81.8% had type 2 diabetes. 413 (65.3%) people were persistent users and 34.7% early quitters. In the multivariable analysis, insulin use (OR2.07; 95%CI[1.18-3.62]), experiencing more frequently hyperglycemic episodes (OR1.30;95%CI[1.14-1.49]) and better diabetes knowledge (OR1.02, 95%CI[1.01-1.03]) do increase the odds of being a persistent user. Persistent users perceived the usefulness of the patient portal significantly more favorable. However, they also more decisively declared that the patient portal is not helpful in supporting life style changes. Early quitters felt significantly more items not applicable in their situation compared to persistent users. Both persistent users (69.8%) and early quitters (58.8%) would prefer a reminder function for scheduled visits. About 60% of both groups wanted information about medication and side-effects in their portal. The diabetes patient web portal might be improved significantly by taking into account the patients' experiences and attitudes. We propose creating separate portals for patients on insulin or not.

  7. Quantitative study of the hemodynamic changes of portal vein in hepatocellular carcinoma with arterioportal shunts

    International Nuclear Information System (INIS)

    Shen Xinying; Shan Hong

    2005-01-01

    Objective: To measure the changes of portal venous pressure before and after APS by percutaneous portal vein catheterization and to quantitatively analyse the correlation between portal pressure and portal hypertension. Methods: All the 18 central arterioportal shunts (APS) patients with hepatocellular carcinoma (HCC) were treated with embolization of APS and TACE, and the pressure of portal vein was measured by percutaneous portal vein catheterization pre- and post-embolization of APS. Color doppler sonography and endoscopy were employed to investigate before and 2 weeks after embolization in all patients. Results: The pressure of portal vein decreased significantly after embolization, and the decreased rate was 5.4%-33.3% with the mean rate 20.1%. After the embolization, the width of portal vein decreased and the blood flow velocity of portal vein increased significantly, P<0.01. Hepatofugal portal venous flow was seen in 13 patients before embolization, and restored to hepatopetal flow in 7 patients after embolization. In the 10 patients with more than 20% decrease in portal venous pressure, the portal hypertension improved markedly; while in other 8 patients with less than 20 percent decrease in portal venous pressure, the clinical symptoms of portal hypertension did not improve as much. Conclusions: Embolization of APS can decrease portal venous pressure, with the mean decreasing rate over 20%. Decreasing by 20% or more of portal venous pressure can improve effectively the portal hypertension symptoms including ascites, variceal bleeding, and diarrhea. (authors)

  8. The application of TIPSS in portal vein cancerous thrombosis complicated with portal hypertension

    International Nuclear Information System (INIS)

    Jiang Zaibo; Shan Hong; Guan Shouhai; Zhu Kangshun; Huang Mingsheng; Li Zhengran; Zhu Wenke; Liu Lang; Guo Tiansheng

    2002-01-01

    Objective: To discuss the technical skills and the contraindication of trans-jugular intrahepatic portosystemic shunt stent (TIPSS) in portal vein cancerous thrombosis (PVCT) complicated with portal hypertension. Methods: There were 16 cases of PVCT with portal hypertension, and average age of 53.6 yr. There were 9 cases with complete occlusion of portal vein trunk and 7 cases with incomplete thrombosis. There were 5 cases with cavernous transformation of the portal vein (CTPV). 1 case of simple upper gastro-intestinal tract (GIT) massive bleeding, 4 with refractory ascites and 11 with upper GIT massive bleeding and refractory ascites. Results: The procedure of TIPS was successful in 11 cases, the successful rate reached about 68.8%. The mean portal vein pressure was reduced from 4.9 kPa to 2.4 kPa with average 2. 5 kPa reduction. Ascites decreased, bleeding stopped and the clinical symptoms disappeared. The average survival period was 136 days. The procedure failed in 5 cases. Conclusions: TIPSS is an effective method to control the bleeding and ascites caused by PVCT. The PV cavernous transformation was the contraindication of TIPSS

  9. Portal-venous gas unrelated to mesenteric ischemia

    International Nuclear Information System (INIS)

    Wiesner, Walter; Mortele, Koenraad J.; Ji, Hoon; Ros, Pablo R.; Glickman, Jonathan N.

    2002-01-01

    The aim of this study was to report on 8 patients with all different non-ischemic etiologies for portal-venous gas and to discuss this rare entity and its potentially misleading CT findings in context with a review of the literature. The CT examinations of eight patients who presented with intrahepatic portal-venous gas, unrelated to bowel ischemia or infarction, were reviewed and compared with their medical records with special emphasis on the pathogenesis and clinical impact of portal-venous gas caused by non-ischemic conditions. The etiologies for portal-venous gas included: abdominal trauma (n=1); large gastric cancer (n=1); prior gastroscopic biopsy (n=1); prior hemicolectomy (n=1); graft-vs-host reaction (n=1); large paracolic abscess (n=1); mesenteric recurrence of ovarian cancer superinfected with clostridium septicum (n=1); and sepsis with Pseudomonas aeruginosa (n=1). The clinical outcome of all patients was determined by their underlying disease and not negatively influenced by the presence of portal-venous gas. Although the presence of portal-venous gas usually raises the suspicion of bowel ischemia and/or intestinal necrosis, this CT finding may be related to a variety of non-ischemic etiologies and pathogeneses as well. The knowledge about these conditions may help to avoid misinterpretation of CT findings, inappropriate clinical uncertainty and unnecessary surgery in certain cases. (orig.)

  10. Determining the optimal portal blood volume in a shunt before surgery in extrahepatic portal hypertension

    Directory of Open Access Journals (Sweden)

    Yurchuk Vladimir A

    2016-04-01

    Full Text Available The aim of the study: To determine the necessary shunt diameter and assess the optimal portal blood volume in a shunt in children with extrahepatic portal hypertension before the portosystemic shunt surgery. Changes in the liver hemodynamics were studied in 81 children aged from 4 to 7 years with extrahepatic portal hypertension. We established that it is necessary to calculate the shunt diameter and the blood volume in a shunt in patients with extrahepatic portal hypertension before the portosystemic shunt surgery. It allows us to preserve the hepatic portal blood flow and effectively decrease the pressure in the portal system. Portosystemic shunt surgery in patients with extrahepatic portal hypertension performed in accordance with the individualized shunt volume significantly decreases portal pressure, preserves stable hepatic hemodynamics and prevents gastro-esophageal hemorrhage.

  11. Transcatheter arterial chemoembolization of hepatocellular carcinoma with portal vein invasion

    International Nuclear Information System (INIS)

    Lee, Young Rahn; Lee, Ki Yeol; Cho, Seong Beom; Cha, In Ho; Chung, Kyoo Byung

    1993-01-01

    Transcatheter arterial chemoembolization(TACE) is an imperative method for the management of inoperable hepatocellular carcinoma(HCC). It is well known that primary HCC frequently invades the portal venous system and forms a tumor thrombus obstructing the portal blood flow which makes unfavorable prognosis of patient. We retrospectively reviewed 58 patients who reviewed TACE(minimum 3 times) of HCC invading into portal venous system. Group 1(n=29) which showed peripheral portal vein invasion had better clinical and laboratory response. Group 2(n=17) which showed first order portal branch invasion had similar response to Group 3(n=12), which had main portal invasion. Group 1 showed no difference in survival time between TAC and TACE, but, in Group 2 and 3, embolization with chemotherapy made longer survival than chemotherapy only. Clinical level of AFP was meaningful in Group 1 and 2 as decreasing value. Our results provides that careful selection of TAE and case by case Coil/Gelfoam embolization can improve the mean survival and clinical response when HCC evidently invades portal venous system

  12. Congestive index of portal vein

    International Nuclear Information System (INIS)

    Kim, Won Ho; Kim, H. K.; Lee, S. C.; Han, S. H.; Han, K. H.; Chung, J. B.; Choi, H. J.

    1989-01-01

    In patients with portal hypertension, the blood flow volume is maintained despite decreased blood flow velocity due to enlargement of the vascular cross sectional area. Thus, the 'congestion index' of the portal vein, which is the ratio between the cross sectional area (cm2) and the blood flow velocity (cm/sec) determined by a Doppler ultrasonography, may be a sensitive index by which to assess portal hypertension. We performed Doppler ultrasonography on 24 normal subjects, 14 patients with biopsy proved chronic active hepatitis and 55 patients with liver cirrhosis in order to assess the diagnostic value of the congestion index. The cross sectional area of the portal vein was significantly enlarged and the mean blood flow velocity was significantly reduced in patients with liver cirrhosis compared with controls. However, the blood flow volume was no difference. The congestion index of the portal vein was significantly increased in patients with liver cirrhosis (0.113+0.035) compared with patients with chronic active hepatitis(0.078+0.029) (p<0.001) and controls (0.053+0.016) (p<0.001). The sensitivity, specificity and predictability of the congestion index for detection of patients with the cirrhosis of the liver were 76.4%, 100% and 100% respectively, when the normal range was set at mean+2SD. The results suggest that the congestion index of the portal vein may pla a significant role in diagnosis of portal hypertensive patients

  13. Management of Portal Hypertension After Liver Transplantation.

    Science.gov (United States)

    Korda, D; Deák, P Á; Kiss, G; Gerlei, Z; Kóbori, L; Görög, D; Fehérvári, I; Piros, L; Máthé, Z; Doros, A

    2017-09-01

    Post-transplantation portal hypertension has severe complications, such as esophageal varix bleeding, therapy refractory ascites, extreme splenomegaly, and graft dysfunction. The aim of our study was to analyze the effectiveness of the therapeutic strategies and how to visualize the procedure. A retrospective study involving liver transplantation patients from the Semmelweis University Department of Transplantation and Surgery was performed between 2005 and 2015. The prevalence, etiology, and leading complications of the condition were determined. The applied interventions' effects on the patients' ascites volume, splenic volume, and the occurrence of variceal bleeding were determined. Mean portal blood flow velocity and congestion index values were calculated using Doppler ultrasonography. The prevalence of post-transplantation portal hypertension requiring intervention was 2.8%. The most common etiology of the disease was portal anastomotic stenosis. The most common complications were esophageal varix bleeding and therapy refractory ascites. The patients' ascites volume decreased significantly (2923.3 ± 1893.2 mL vs. 423.3 ± 634.3 mL; P portal hypertension. After the interventions, these parameters shifted towards the physiologic ranges. The interventions performed in our clinic were effective in most cases. The patients' ascites volume, splenic volume, and the prevalence of variceal bleeding decreased after the treatment. Doppler ultrasonography has proved to be a valuable imaging modality in the diagnosis and the follow-up of post-transplantation portal hypertension. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Wall shear stress in portal vein of cirrhotic patients with portal hypertension.

    Science.gov (United States)

    Wei, Wei; Pu, Yan-Song; Wang, Xin-Kai; Jiang, An; Zhou, Rui; Li, Yu; Zhang, Qiu-Juan; Wei, Ya-Juan; Chen, Bin; Li, Zong-Fang

    2017-05-14

    To investigate wall shear stress (WSS) magnitude and distribution in cirrhotic patients with portal hypertension using computational fluid dynamics. Idealized portal vein (PV) system models were reconstructed with different angles of the PV-splenic vein (SV) and superior mesenteric vein (SMV)-SV. Patient-specific models were created according to enhanced computed tomography images. WSS was simulated by using a finite-element analyzer, regarding the blood as a Newtonian fluid and the vessel as a rigid wall. Analysis was carried out to compare the WSS in the portal hypertension group with that in healthy controls. For the idealized models, WSS in the portal hypertension group (0-10 dyn/cm 2 ) was significantly lower than that in the healthy controls (10-20 dyn/cm 2 ), and low WSS area (0-1 dyn/cm 2 ) only occurred in the left wall of the PV in the portal hypertension group. Different angles of PV-SV and SMV-SV had different effects on the magnitude and distribution of WSS, and low WSS area often occurred in smaller PV-SV angle and larger SMV-SV angle. In the patient-specific models, WSS in the cirrhotic patients with portal hypertension (10.13 ± 1.34 dyn/cm 2 ) was also significantly lower than that in the healthy controls ( P portal hypertension, the low WSS area extended to wider levels and the magnitude of WSS reached lower levels, thereby being more prone to disturbed flow occurrence. Cirrhotic patients with portal hypertension show dramatic hemodynamic changes with lower WSS and greater potential for disturbed flow, representing a possible causative factor of PV thrombosis.

  15. Palliative treatment of TIPS to portal vein tumor thrombosis complicated with portal vein hypertension

    International Nuclear Information System (INIS)

    Jiang Zaibo; Shan Hong; Guan Shouhai; Zhu Kangshun; Huang Mingsheng; Li Zhengran; Guo Tiansheng; Liu Lang

    2002-01-01

    Objective: To evaluate the palliative therapeutic effects of transjugular intrahepatic portosystemic shunt (TIPS) in portal vein tumor thrombosis (PVTT) complicated with portal vein hypertension, and to discuss the technical skills. Methods: There were 14 cases of end-stage hepatocellular carcinoma complicated with PVTT and portal vein hypertension, the average age was 53.6 yr. There were 8 cases with complete occlusion of main portal vein, 6 eases with incomplete thrombosis, and 5 cases combined with portal vein cavernous transformation. One case had simple hemorrhage, 3 eases had intractable ascites, and 10 cases had hemorrhage accompanied by intractable ascites. Results: The procedure of TIPS was successful in 10 cases, the successful rate was about 71%. The mean portal vein pressure was reduced from 37.2 mm Hg to 18.2 mm Hg, with an average reduction of 19.0 mm Hg. After the procedure of TIPS, the ascites decreased, hemorrhage stopped and the clinical symptoms disappeared. The average survival period was 132.3 days. The procedure were failing in 4 cases. Conclusion: TIPS was an effective palliative therapeutic methods to control the hemorrhage and ascites aroused by hepatic carcinoma complicated with PVTT

  16. A novel canine model of portal vein stenosis plus thioacetamide administration-induced cirrhotic portal hypertension with hypersplenism.

    Science.gov (United States)

    Lin, Dexin; Wu, Xianbin; Ji, Xiaoke; Zhang, Qiyu; Lin, YuanWei; Chen, WeiJian; Jin, Wangxun; Deng, Liming; Chen, Yunzhi; Chen, Bicheng; Li, Jianmin

    2012-01-01

    Current large animal models that could closely resemble the typical features of cirrhotic portal hypertension in human have not been well established. Thus, we aimed to develop and describe a reliable and reproducible canine cirrhosis model of portal hypertension. A total of 30 mongrel dogs were randomly divided into four groups: 1 (control; n = 5), 2 (portal vein stenosis [PVS]; n = 5], 3 (thioacetamide [TAA]; n = 5), and 4 (PVS plus TAA; n = 15). After 4-months modeling period, liver and spleen CT perfusion, abdominal CT scans, portal hemodynamics, gastroscopy, hepatic function, blood routine, the bone marrow, liver, and spleen histology were studied. The animals in group 2 (PVS) developed extrahepatic portosystemic collateral circulation, particularly esophageal varices, without hepatic cirrhosis and portal hypertension. Animals from group 3 (TAA) presented mild cirrhosis and portal hypertension without significant symptoms of esophageal varices and hypersplenism. In contrast, animals from group 4 (PVS + TAA) showed well-developed micronodular and macronodular cirrhosis, associated with significant portal hypertension and hypersplenism. The combination of PVS and TAA represents a novel, reliable, and reproducible canine cirrhosis model of portal hypertension, which is associated with the typical characteristics of portal hypertension, including hypersplenism.

  17. Secure messaging and diabetes management: experiences and perspectives of patient portal users.

    Science.gov (United States)

    Wade-Vuturo, Ashley E; Mayberry, Lindsay Satterwhite; Osborn, Chandra Y

    2013-05-01

    Patient portal use has been associated with favorable outcomes, but we know less about how patients use and benefit from specific patient portal features. Using mixed-methods, we explored how adults with type 2 diabetes (T2DM) use and benefit from secure messaging (SM) within a patient portal. Adults with T2DM who had used a patient portal participated in a focus group and completed a survey (n=39) or completed a survey only (n=15). We performed thematic analysis of focus group transcripts to identify the benefits of and barriers to using SM within a portal. We also examined the association between use of various patient portal features and patients' glycemic control. Participants were on average 57.1 years old; 65% were female; 76% were Caucasian/White, and 20% were African American/Black. Self-reported benefits of SM within a portal included enhanced patient satisfaction, enhanced efficiency and quality of face-to-face visits, and access to clinical care outside traditional face-to-face visits. Self-reported barriers to using SM within a portal included preconceived beliefs or rules about SM and prior negative experiences with SM. Participants' assumptions about providers' opinions about SM and providers' instructions about SM also influenced use. Greater self-reported use of SM to manage a medical appointment was significantly associated with patients' glycemic control (ρ=-0.29, p=0.04). SM within a portal may facilitate access to care, enhance the quality of office visits, and be associated with patient satisfaction and clinical outcomes for patients with diabetes, but provider communication about SM is essential.

  18. Cavernous transformation of the portal vein

    International Nuclear Information System (INIS)

    Lehotska, V.; Dostalova, K.; Durkovsky, A.; Samal, V.

    1995-01-01

    In this contribution, the authors give an account of a rare case of a cavernous transformation of the portal vein that may have originated secondarily in a proliferative hematogenous disease with a polyglobulia and thrombosis in the periferal blood count as well as development of portal hypertension of a prehepatal type. The state of hyper-coagulation in a myeloproliferative disease may have lead to a chronic thrombosis of the portal vein with a subsequent malformation of the portal vein in terms of a cavernous transformation of the portal vein. The case is an interesting one because of the discrepancy between the gravity of the thrombotic complication and slightness of the symptoms in the clinical picture. The authors point out the importance of ultrasonography and computed tomography examination following the intravenous application of a water solution of a contrast medium in a morphologic diagnosing of a rare complication of a chronic thrombotic clot of the portal vein - the cavernous transformation. (authors)

  19. Clinical value of liver and spleen shear wave velocity in predicting the prognosis of patients with portal hypertension.

    Science.gov (United States)

    Zhang, Yan; Mao, Da-Feng; Zhang, Mei-Wu; Fan, Xiao-Xiang

    2017-12-07

    To explore the relationship of liver and spleen shear wave velocity in patients with liver cirrhosis combined with portal hypertension, and assess the value of liver and spleen shear wave velocity in predicting the prognosis of patients with portal hypertension. All 67 patients with liver cirrhosis diagnosed as portal hypertension by hepatic venous pressure gradient in our hospital from June 2014 to December 2014 were enrolled into this study. The baseline information of these patients was recorded. Furthermore, 67 patients were followed-up at 20 mo after treatment, and liver and spleen shear wave velocity were measured by acoustic radiation force impulse at the 1 st week, 3 rd month and 9 th month after treatment. Patients with favorable prognosis were assigned into the favorable prognosis group, while patients with unfavorable prognosis were assigned into the unfavorable prognosis group. The variation and difference in liver and spleen shear wave velocity in these two groups were analyzed by repeated measurement analysis of variance. Meanwhile, in order to evaluate the effect of liver and spleen shear wave velocity on the prognosis of patients with portal hypertension, Cox's proportional hazard regression model analysis was applied. The ability of those factors in predicting the prognosis of patients with portal hypertension was calculated through receiver operating characteristic (ROC) curves. The liver and spleen shear wave velocity in the favorable prognosis group revealed a clear decline, while those in the unfavorable prognosis group revealed an increasing tendency at different time points. Furthermore, liver and spleen shear wave velocity was higher in the unfavorable prognosis group, compared with the favorable prognosis group; the differences were statistically significant ( P portal hypertension was significantly affected by spleen hardness at the 3 rd month after treatment [relative risk (RR) = 3.481]. At the 9 th month after treatment, the prognosis

  20. ASH External Web Portal (External Portal) -

    Data.gov (United States)

    Department of Transportation — The ASH External Web Portal is a web-based portal that provides single sign-on functionality, making the web portal a single location from which to be authenticated...

  1. Portal vein thrombosis is a potentially preventable complication in clinical islet transplantation

    Science.gov (United States)

    Kawahara, Toshiyasu; Kin, Tatsuya; Kashkoush, Samy; Gala-Lopez, Boris; Bigam, David L.; Kneteman, Norman M.; Koh, Angela; Senior, Peter A.; Shapiro, A.M. James

    2011-01-01

    Percutaneous transhepatic portal access avoids surgery, but is rarely associated with bleeding or portal venous thrombosis. We herein report our large, single-center experience of percutaneous islet implantation, and evaluate risk factors of portal vein thrombosis and graft function. Prospective data was collected on 268 intraportal islet transplants (122 subjects). A portal venous Doppler ultrasound was obtained on Days 1 and 7 days posttransplant. Therapeutic heparinization, complete ablation of the portal catheter tract with Avitene paste, and limiting packed cell volume to islet transplant procedures over the past 5 years. In the previous cumulative experience, partial thrombosis did not affect islet function. Standard liver volume correlated negatively (r=−0.257, Pislet transplantation, provided therapeutic anticoagulation is maintained, and packed cell volume is limited to <5 ml. PMID:21883914

  2. Dynamic CT of portal hypertensive gastropathy: significance of transient gastric perfusion defect sign

    International Nuclear Information System (INIS)

    Kim, T.U.; Kim, S.; Woo, S.K.; Lee, J.W.; Lee, T.H.; Jeong, Y.J.; Heo, J.

    2008-01-01

    Aim: To evaluate the 'transient gastric perfusion defect' sign as a way of diagnosing portal hypertensive gastropathy (PHG) on multidetector computed tomography (CT). Materials and methods: Ninety-two consecutive patients with cirrhosis underwent three-phase CT and endoscopy. Endoscopy was performed within 3 days of the CT examination. As controls, 92 patients without clinical evidence of chronic liver diseases who underwent CT and endoscopy were enrolled; the findings at endoscopy were used as a reference standard for patients with PHG. Two radiologists who were unaware of the results of the endoscopy retrospectively interpreted the CT images. PHG was diagnosed on dynamic CT if the transient gastric perfusion defect sign was present. The transient gastric perfusion defect was defined as the presence of transient, segmental or subsegmental hypo-attenuating mucosa in the fundus or body of the stomach on hepatic arterial imaging that returned to normal attenuation on portal venous or equilibrium-phase imaging. The frequency of the transient gastric perfusion defect sign was compared between these two groups using Fisher's exact test. The frequency, sensitivity, specificity, positive predictive values, and negative predictive values of the transient gastric perfusion defect sign were also compared between patients with PHG and without PHG in the cirrhosis group. Results: Nine patients of 92 patients with cirrhosis were excluded because of previous procedure or motion artifact; the remaining 83 patients with cirrhosis were evaluated. In the cirrhosis group, 40 (48.1%) of 83 patients showed the transient gastric perfusion defect sign. In the control group, none of the 92 patients showed the transient gastric perfusion defect sign. In the cirrhotic group, the frequency of the transient gastric perfusion defect sign was significantly higher in the patients with PHG (75%, 36/48) than in patients without PHG (11.4%, 4/35). The sensitivity, specificity, positive predictive

  3. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1995-01-01

    Purpose/Objective: The purpose of this presentation is to review the physics of imaging with high energy x-ray beams; examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine errors in patient positioning quantitatively; and discuss some of the ways that portal imaging has been incorporated into routine clinical practice. Verification of patient positioning has always been an important aspect of external beam radiation therapy. Checks of patient positioning have generally been done with film, however, film suffers from a number of drawbacks, such as poor image display and delays due to film development. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems, which are intended to overcome the limitations of portal films. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The fundamental factors which limit image quality and the characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same

  4. Regional blood flows by the microsphere method: reproducibility in portal hypertensive rats and influence of a portal vein catheter

    International Nuclear Information System (INIS)

    Hadengue, A.; Lee, S.S.; Koshy, A.; Girod, C.; Lebrec, D.

    1988-01-01

    To determine the reproducibility of splanchnic blood flow measurements by the microsphere method in rats with portal hypertension and the effects of laparotomy with portal vein cannulation, eight groups of 10 rats were studied. Microspheres were labelled with 113 Sn or 141 Ce. Laparotomy with portal cannulation had no significant effect in sham-operated rats. In awake portal hypertensive rats, cardiac output and splanchnic blood flow were lower in portal vein cannulated rats compared with those of non-cannulated animals. In anesthetized portal hypertensive rats blood flows were unaffected by portal cannulation, but arterial pressure and heart rate were elevated. Anesthesia also decreased portal pressure in portal hypertensive rats. We conclude that the microsphere method remains reproducible in portal hypertensive rat models. Laparotomy with portal cannulation can alter systemic and splanchnic hemodynamics in portal hypertensive rats; these effects can also be changed during pentobarbital anesthesia. Regional blood flow measurements in portal hypertensive rats should be performed in animals without portal cannulation and preferably in the awake state

  5. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1997-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging, describe some of the image registration methods that have been developed to determine geometric errors quantitatively, and discuss how portal imaging has been incorporated into clinical practice. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices include T.V. camera-based systems, liquid ionisation chamber systems, and shortly, flat panel systems. The characteristics of these imaging systems will be discussed. In addition, other approaches such as the use of kilovoltage x-ray sources, video monitoring, and ultrasound have been proposed for improving patient positioning. Some of the advantages of these approaches will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. One problem is finding a common frame of reference for the simulator and portal images, since the location of the radiation field within the pixel matrix may differ for the two images. As a result, a common frame of reference has to be established before the anatomic structures in the images can be registered - generally by registering radiation field edges identified in the simulator and portal images. In addition, distortions in patient geometry or rotations out of the image plane can confound the image registration techniques. Despite the

  6. Quantitative vs. subjective portal verification using digital portal images

    International Nuclear Information System (INIS)

    Bissett, Randy; Leszczynski, Konrad; Loose, Stephen; Boyko, Susan; Dunscombe, Peter

    1996-01-01

    four oncologists, the portals classified as unacceptable, in terms of the field placement, exhibited significantly higher (p < 0.03) translational errors in the transverse direction. The field coverages were significantly lower (p < 0.05) and the translational errors in the cranio-caudal direction were significantly higher (p < 0.05) for the portals rated as unacceptable by two of the oncologists. Conclusions: From the parameters that were used to quantify the degree of conformity between the prescription and treatment fields, the translational error in the transverse direction correlated best with the oncologists' assessments on the field placement. Field coverage and translational error in the cranio-caudal direction correlated well with assessments of only two out of the four participating oncologists. This can be explained by the fact that for the majority of treatment sites included in the study the positioning of field borders was more critical for the transverse direction. A conclusion for the design of future quantitative and automated on-line portal verification systems is that they will have to model different perceived significances of different types of localization errors intrinsic to oncologist evaluation of portal images

  7. Research advances in non-cirrhotic portal hypertension

    Directory of Open Access Journals (Sweden)

    ZHANG Bojing

    2016-02-01

    Full Text Available Although liver cirrhosis is the most common cause of portal hypertension (PH, about 20% of PH cases are caused by non-cirrhotic reasons, which are referred to as non-cirrhotic portal hypertension (NCPH, with a high incidence rate in developing countries. NCPH is a group of heterogeneous hepatic vascular diseases, including idiopathic portal hypertension (IPH and extrahepatic portal vein obstruction (EHPVO, as well as the rare diseases in clinical practice such as Budd-Chiari syndrome, congenital hepatic fibrosis, and nodular regenerative hyperplasia. The patients with NCPH usually have the symptoms of portal hypertension, such as recurrent variceal bleeding and splenomegaly, but liver function is well preserved in these patients. At present, the diagnosis of NCPH lacks a universally accepted standard and remains a challenge. In clinical practice, the method of exclusion is usually applied for the diagnosis of HCPH, and liver biopsy is performed when necessary to make a confirmed diagnosis. This paper introduces the pathogenesis and pathological manifestations of IPH and EHPVO, as well as the selection of diagnostic methods and therapeutic strategies. If upper gastrointestinal bleeding can be effectively controlled, NCPH is considered to have a relatively good prognosis.

  8. Radionuclide hepatic perfusion index and ultrasonography: Assessment of portal hypertension in clinical practice

    International Nuclear Information System (INIS)

    Seidlova, V.; Hobza, J.; Pumprla, J.; Charouzek, J.

    1989-01-01

    The application is described of radionuclide angiography with hepatic perfusion index (HPI) determination in diagnosis of portal blood flow as an indicator of portal hypertension. 99m Tc and 113 In were used as tracers. Over forty patients suffering from chronic hepatitis or liver cirrhosis were included in the study. Ultrasound was used as a preliminary rapid diagnosis of portal hypertension. Radionuclide angiography combined with the HPI technique was confirmed to be a beneficial noninvasive method offering reproducible quantitative information on portal flow well correlating with the degree of portal hypertension, while the combination of ultrasound examination with radionuclide HPI determination appears to greatly enrich the diagnostic potential in hepatology. (L.O.). 4 figs., 11 refs

  9. Pregnancy with Portal Hypertension

    Science.gov (United States)

    Aggarwal, Neelam; Negi, Neha; Aggarwal, Aakash; Bodh, Vijay; Dhiman, Radha K.

    2014-01-01

    Even though pregnancy is rare with cirrhosis and advanced liver disease, but it may co-exist in the setting of non-cirrhotic portal hypertension as liver function is preserved but whenever encountered together is a complex clinical dilemma. Pregnancy in a patient with portal hypertension presents a special challenge to the obstetrician as so-called physiological hemodynamic changes associated with pregnancy, needed for meeting demands of the growing fetus, worsen the portal hypertension thereby putting mother at risk of potentially life-threatening complications like variceal hemorrhage. Risks of variceal bleed and hepatic decompensation increase many fold during pregnancy. Optimal management revolves round managing the portal hypertension and its complications. Thus management of such cases requires multi-speciality approach involving obstetricians experienced in dealing with high risk cases, hepatologists, anesthetists and neonatologists. With advancement in medical field, pregnancy is not contra-indicated in these women, as was previously believed. This article focuses on the different aspects of pregnancy with portal hypertension with special emphasis on specific cause wise treatment options to decrease the variceal bleed and hepatic decompensation. Based on extensive review of literature, management from pre-conceptional period to postpartum is outlined in order to have optimal maternal and perinatal outcomes. PMID:25755552

  10. APTR is a prognostic marker in cirrhotic patients with portal hypertension during TIPS procedure.

    Science.gov (United States)

    Yu, Shanshan; Qi, Yanhua; Jiang, Jue; Wang, Hua; Zhou, Qi

    2018-03-01

    Portal hypertension is a major cause of mortality and morbidity in cirrhotic patients. In this study, we aimed to analyze the clinical characteristics of Alu-mediated p21 transcriptional regulator (APTR) during transjugular intrahepatic portosystemic shunt (TIPS) procedure. Portal and hepatic venous blood was drawn from 84 patients with liver cirrhosis and portal hypertension before and after TIPS treatment. Then, we detected biochemical, hemodynamic parameters and APTR expression before and after TIPS treatment. Indeed, TIPS treatment could markedly ameliorate the serum blood urea nitrogen (BUN) level and portal vein hemodynamics in cirrhotic patients. We found that portal venous levels of APTR was significantly decreased after TIPS treatment and its aberrant expression levels were positively correlated with Model for End Stage Liver Disease (MELD), portal hepatic venous pressure gradient (PHPG) in patients. Higher APTR expression in portal vein was associated with poor prognosis. APTR level in portal vein was an independent predictors of mortality. Our data indicated that APTR may serve as a novel biomarker for cirrhotic patients with portal hypertension before and after receiving TIPS. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Pathology of idiopathic non-cirrhotic portal hypertension.

    Science.gov (United States)

    Guido, Maria; Sarcognato, Samantha; Sacchi, Diana; Colloredo, Guido

    2018-04-12

    Idiopathic non-cirrhotic portal hypertension is an under-recognized vascular liver disease of unknown etiology, characterized by clinical signs of portal hypertension in the absence of cirrhosis. By definition, any disorder known to cause portal hypertension in the absence of cirrhosis and any cause of chronic liver disease must be excluded to make a diagnosis of idiopathic non-cirrhotic portal hypertension. However, the diagnosis is often difficult because the disease resembles cirrhosis and there is no gold standard test. Liver biopsy is an essential tool: it is able to exclude cirrhosis and other causes of portal hypertension and it allows the identification of the characteristic lesions. Nonetheless, the histological diagnosis of idiopathic non-cirrhotic portal hypertension is not always straightforward, in particular by needle biopsy samples, because there is no pathognomonic lesion, but rather a variety of vascular changes which are unevenly distributed, very subtle, and not all necessarily identified in a single specimen. Pathologists should be able to recognize several patterns of injury, involving portal/periportal areas as well as parenchymal structures.The histological features of idiopathic non-cirrhotic portal hypertension are described in this review, focusing on their interpretation in needle biopsy specimens.

  12. Plasma catecholamine level and portal venous pressure as guides to prognosis in patients with cirrhosis

    DEFF Research Database (Denmark)

    Tage-Jensen, U; Henriksen, Jens Henrik; Christensen, E

    1988-01-01

    clinical and biochemical variables and survival. Forty-seven (58%) of the patients died during the follow-up period. Univariate analysis showed that plasma noradrenaline and adrenaline concentrations, portal pressure, indocyanine green clearance, serum sodium, bilirubin, and albumin concentrations......, and the presence of ascites or cardiovascular disease were of significant prognostic value. In a multivariate analysis (Cox regression model), plasma noradrenaline concentration, portal pressure, serum bilirubin concentration, and the presence of ascites and cardiovascular disease remained significant independent...

  13. Mid-term effect of direct intrahepatic portosystemic shunt for the treatment of portal hypertension

    International Nuclear Information System (INIS)

    Luo Jianjun; Yan Zhiping; Wang Jianhua; Liu Qingxin; Qu Xudong

    2009-01-01

    Objective: To retrospectively analyze the mid-term clinical results of direct intrahepatic portosystemic shunt (DIPS) in treating patients with portal hypertension. Methods: DIPS were created in 23 patients with portal hypertension. Both preoperative and postoperative portal systemic pressure gradient (PPG), liver function and clinical symptoms were recorded and compared. Shunt patency was checked by color Doppler ultrasonography and the data were statistically analyzed by Kaplan-Meier method. Results DIPS creation was successfully accomplished in all 23 patients. No serious complications occurred after DIPS except for hemorrhagic ascites (n = 1) and mild hepatic encephalopathy (n = 3). Mean PPG significantly decreased from preoperative (32.6 ± 5.3) mmHg with a range of (23 - 43) mmHg to postoperative (10.1 ± 2.7) mmHg with a range of (5-14) mmHg (P < 0.001). After the procedure, the albumin level also markedly decreased while the bilirubin level distinctly increased. Obvious improvement of the clinical symptoms was observed. The cumulated primary patency rate of the shunt one and two years after treatment was 77.4% and 50.2% respectively. Conclusion: The mid-term clinical results indicate that DIPS is an effective and safe procedure for treating patients with portal hypertension. (authors)

  14. Development and clinical implementation of an enhanced display algorithm for use in networked electronic portal imaging

    International Nuclear Information System (INIS)

    Heuvel, Frank van den; Han, Ihn; Chungbin, Suzanne; Strowbridge, Amy; Tekyi-Mensah, Sam; Ragan, Don P.

    1999-01-01

    Purpose: To introduce and clinically validate a preprocessing algorithm that allows clinical images from an electronic portal imaging device (EPID) to be displayed on any computer monitor, without loss of clinical usability. The introduction of such a system frees EPI systems from the constraints of fixed viewing workstations and increases mobility of the images in a department. Methods and Materials: The preprocessing algorithm, together with its variable parameters is introduced. Clinically, the algorithm is tested using an observer study of 316 EPID images of the pelvic region in the framework of treatment of carcinoma of the cervix and endometrium. Both anterior-posterior (AP/PA) and latero-lateral (LAT) images were used. The images scored were taken from six different patients, five of whom were obese, female, and postmenopausal. The result is tentatively compared with results from other groups. The scoring system, based on the number of visible landmarks in the port, is proposed and validated. Validation was performed by having the observer panel score images with artificially induced noise levels. A comparative study was undertaken with a standard automatic window and leveling display technique. Finally, some case studies using different image sites and EPI detectors are presented. Results: The image quality for all images in this study was deemed to be clinically useful (mean score > 1). Most of the images received a score which was second highest (AP/PA landmarks ≥ 6 and LAT landmarks ≥ 5). Obesity, which has been an important factor determining the image quality, was not seen to be a factor here. Compared to standard techniques a highly significant improvement was determined with regard to clinical usefulness. The algorithm performs fast (less than 9 seconds) and needs no additional user interaction in most of the cases. The algorithm works well on both direct detection portal imagers and camera-based imagers whether analog or digital cameras

  15. Nitro-oxidative stress, VEGF and MMP-9 in patients with cirrhotic and non-cirrhotic portal hypertension.

    Science.gov (United States)

    Muti, Leon Adrian; Pârvu, Alina Elena; Crăciun, Alexandra M; Miron, Nicolae; Acalovschi, Monica

    2015-01-01

    Nitro-oxidative stress may have pathophysiological consequences. The study aimed to assess the nitro-oxidative stress, the vascular growth factor, and metalloproteinase-9 levels in patients with noncirrohic and cirrhotic portal hypertension. Patients with noncirrhotic portal hypertension (n=50) and cirrhotic portal hypertension (n=50) from the 3rd Medical Clinic in Cluj-Napoca Romania were prospectively enrolled between October 2004 and October 2006. A control group of healthy volunteers (n=50) was also evaluated. Nitro-oxidative stress was assessed by measuring serum concentration of nitrites and nitrate, 3-nitrotyrosine, total oxidative status, total antioxidant reactivity, and oxidative stress index. Serum vascular growth factor and matrix metalloproteinase-9 were also determined. Serum nitrites and nitrate levels significantly increased in both noncirrhotic (pportal hypertension (p=0.057). 3-nitrotyrosine also increased in noncirrhotic (p=0.001) and cirrhotic portal hypertension patients (p=0.014). Total oxidative status showed a significant increase in noncirrhotic (pportal hypertension (pportal hypertension (pportal hypertension a significant systemic nitro-oxidative stress was found, correlated with an increase of VEGF. MMP-9 decreased in noncirrhotic portal hypertension.

  16. BRAZILIAN NEWS PORTALS CHARACTERISTICS

    Directory of Open Access Journals (Sweden)

    Heloiza G. Herckovitz

    2011-02-01

    Full Text Available A content analysis of four Brazilian news media portals found that economic news dominated the top headlines with little attention paid to education, the environment and welfare. Other trends included a focus on local events and national news sources, reliance on few sources, mostly official ones, and a low percentage of news that fitted the concept of newsworthiness (a combination of both social significance and deviance concepts. Other findings of a study of 432 top news stories published by UOL, Estadão, iG and Terra during a 15-day period between February and March 2008 indicate that the top portions of the portals’ front pages carry news that lacks story depth, editorial branding, and multimedia applications. The results suggest that online news portals are in their infancy although Brazil has the largest online population of Latin America. This study hopes to shed light on the gatekeeping process in Brazilian news portals. Brazilian media portals have yet to become a significant editorial force able to provide knowledge about social issues and public affairs in a socially responsible fashione.

  17. Portal Vein Stenting for Portal Biliopathy with Jaundice

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Dongho, E-mail: mesentery@naver.com; Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center (Korea, Republic of); Lim, Seong Joo [Konyang University, Department of Radiology, College of Medicine, Konyang University Hospital (Korea, Republic of); Hwang, Jin Ho [Hallym University Sacred Heart Hospital, Department of Radiology (Korea, Republic of); Sinn, Dong Hyun [Sungkyunkwan University School of Medicine, Department of Medicine, Samsung Medical Center (Korea, Republic of)

    2016-04-15

    Portal biliopathy refers to obstruction of the bile duct by dilated peri- or para-ductal collateral channels following the main portal vein occlusion from various causes. Surgical shunt operation or endoscopic treatment has been reported. Herein, we report a case of portal biliopathy that was successfully treated by interventional portal vein recanalization.

  18. Oncogenomic portals for the visualization and analysis of genome-wide cancer data.

    Science.gov (United States)

    Klonowska, Katarzyna; Czubak, Karol; Wojciechowska, Marzena; Handschuh, Luiza; Zmienko, Agnieszka; Figlerowicz, Marek; Dams-Kozlowska, Hanna; Kozlowski, Piotr

    2016-01-05

    Somatically acquired genomic alterations that drive oncogenic cellular processes are of great scientific and clinical interest. Since the initiation of large-scale cancer genomic projects (e.g., the Cancer Genome Project, The Cancer Genome Atlas, and the International Cancer Genome Consortium cancer genome projects), a number of web-based portals have been created to facilitate access to multidimensional oncogenomic data and assist with the interpretation of the data. The portals provide the visualization of small-size mutations, copy number variations, methylation, and gene/protein expression data that can be correlated with the available clinical, epidemiological, and molecular features. Additionally, the portals enable to analyze the gathered data with the use of various user-friendly statistical tools. Herein, we present a highly illustrated review of seven portals, i.e., Tumorscape, UCSC Cancer Genomics Browser, ICGC Data Portal, COSMIC, cBioPortal, IntOGen, and BioProfiling.de. All of the selected portals are user-friendly and can be exploited by scientists from different cancer-associated fields, including those without bioinformatics background. It is expected that the use of the portals will contribute to a better understanding of cancer molecular etiology and will ultimately accelerate the translation of genomic knowledge into clinical practice.

  19. Anatomy of the Portal Vein Bifurcation: Implication for Transjugular Intrahepatic Portal Systemic Shunts

    International Nuclear Information System (INIS)

    Kwok, Philip Chong-hei; Ng, Wai Fu; Lam, Christine Suk-yee; Tsui, Polly Po; Faruqi, Asma

    2003-01-01

    Purpose: The relationship of the portalvein bifurcation to the liver capsule in Asians, which is an important landmark for transjugular intrahepatic portosystemic shunt, has not previously been described. Methods: The anatomy of the portal vein bifurcation was studied in 70 adult Chinese cadavers; it was characterized as intrahepatic or extrahepatic. The length of the exposed portion of the right and left portal veins was measured when the bifurcation was extrahepatic. Results: The portal vein bifurcation was intrahepatic in 37 cadavers (53%) and extrahepatic in 33 cadavers (47%). The mean length of the right and left extrahepatic portal veins was 0.96 cm and 0.85 cm respectively.Both were less than or equal to 2 cm in 94% of the cadavers with extrahepatic bifurcation. There was no correlation between the presence of cirrhosis and the location of the portal vein bifurcation(p 1.0). There was no statistically significant difference in liver mass in cadavers with either extrahepatic or intrahepatic bifurcation (p =0.40). Conclusions: These findings suggest that fortransjugular intrahepatic portosystemic shunt placement, a portal vein puncture 2 cm from the bifurcation will be safe in most cases

  20. Portal Vein Thrombosis

    Directory of Open Access Journals (Sweden)

    Hakan Demirci

    2016-01-01

    Full Text Available Portal vein thrombosis is an important cause of presinusoidal portal hypertension. Portal vein thrombosis commonly occurs in patient with cirrhosis, malignancy and prothrombotic states. Patients with acute portal vein thrombosis have immediate onset. Patients with chronic portal vein thrombosis have developed portal hypertension and cavernous portal transformation. Portal vein thrombosis is diagnosed with doppler ultrasound, computed tomography and magnetic resonance imaging. Therapy with low molecular weight heparin achieves recanalization in more than half of acute cases.

  1. Liver surgery in cirrhosis and portal hypertension.

    Science.gov (United States)

    Hackl, Christina; Schlitt, Hans J; Renner, Philipp; Lang, Sven A

    2016-03-07

    The prevalence of hepatic cirrhosis in Europe and the United States, currently 250 patients per 100000 inhabitants, is steadily increasing. Thus, we observe a significant increase in patients with cirrhosis and portal hypertension needing liver resections for primary or metastatic lesions. However, extended liver resections in patients with underlying hepatic cirrhosis and portal hypertension still represent a medical challenge in regard to perioperative morbidity, surgical management and postoperative outcome. The Barcelona Clinic Liver Cancer classification recommends to restrict curative liver resections for hepatocellular carcinoma in cirrhotic patients to early tumor stages in patients with Child A cirrhosis not showing portal hypertension. However, during the last two decades, relevant improvements in preoperative diagnostic, perioperative hepatologic and intensive care management as well as in surgical techniques during hepatic resections have rendered even extended liver resections in higher-degree cirrhotic patients with portal hypertension possible. However, there are few standard indications for hepatic resections in cirrhotic patients and risk stratifications have to be performed in an interdisciplinary setting for each individual patient. We here review the indications, the preoperative risk-stratifications, the morbidity and the mortality of extended resections for primary and metastatic lesions in cirrhotic livers. Furthermore, we provide a review of literature on perioperative management in cirrhotic patients needing extrahepatic abdominal surgery and an overview of surgical options in the treatment of hepatic cirrhosis.

  2. A study of trans-rectal portal scintigraphy for the diagnostic evaluation of portal hypertension with hepatic cirrhosis

    International Nuclear Information System (INIS)

    Tang Mingdeng; Dong Weiyu; Liu Yonghua; He Pinyu; Li Zhener

    1996-01-01

    The portal hypertension of hepatic cirrhosis was studied by 99m Tc-MIBI trans-rectum imaging. The portal systemic circulation was evaluated by the heart-liver ratio (H/L ratio) and the portosystemic shunt index (SI). The H/L and SI in 12 normal cases were 0.145 +- 0.042 and 0.124 +- 0.029. Whereas in 18 patients with hepatobiliary diseases of non-cirrhosis were 0.207 +- 0.076 and 0.169 +- 0.051, and in 47 patients with hepatic cirrhosis were 0.751 +-0.313 and 0.422 +- 0.075. The results showed significant difference (P<0.01) between normal controls and non-cirrhosis group, and significant difference (P<0.001) between hepatic cirrhosis group and normal controls, non-cirrhosis group. A significant difference (P<0.05) in child-pugh's classification A, B and C groups was also found. A significant correlation (r = 0.95, P<0.01) with the H/L, SI and portal pressure measurement during operation was found. If H/L≥0.30, and SI≥0.22 were taken as positive criteria for diagnosis of portal hypertension with hepatic cirrhosis, the sensitivity, specificity and accuracy were 96%, 90% and 94% respectively. Therefore, it was a new method for the diagnosis of portal hypertension with hepatic cirrhosis

  3. Glutamine prevents gastric oxidative stress in an animal model of portal hypertension gastropathy.

    Science.gov (United States)

    Marques, Camila; Mauriz, José L; Simonetto, Douglas; Marroni, Claudio A; Tuñon, María J; González-Gallego, Javier; Marrón, Norma P

    2011-01-01

    Portal hypertension (PHI) is a clinical syndrome characterized by increases of the blood flow and/or of the vascular resistance in the portal system. A direct consequence of PHI can appearance different lesions on the gastric mucosa and submucosa, cumulatively termed portal hypertensive gastropathy (PHG). To investigate the effects of glutamine on oxidative stress in an experimental model of PHG induced by partial portal vein ligation (PPVL). Portal pressure, transaminase and alkaline phosphatase activity were quantified. Gastric tissue damage was assessed by histological analysis. Oxidative stress was measured by quantification of cytosolic concentration of thiobarbituric acid reactive substances (TBARS), hydroperoxide-initiated chemiluminescence (QL), and nitric oxide (NO) production. Moreover, activities of the antioxidant enzymes superoxide dismutase (SOD), glutathione peroxidase (GPx), and catalase (CAT) were analyzed. Transaminase and alkaline phosphatase activities were not significantly modified by PPVL, indicating absence of liver injury. Histological analysis of gastric sections showed a lost of normal architecture, with edema and vasodilatation. TBARS, QL, and NO production were significantly increased in PPVL animals. A reduction of SOD activity was found. Glutamine administration markedly alleviated histological abnormalities and oxidative stress, normalized SOD activity, and blocked NO overproduction. Our results confirm that the use of molecules with antioxidant capacity can provide protection of the gastric tissue in portal hypertension. Glutamine treatment can be useful to reduce the oxidative damage induced by PHI on gastric tissue.

  4. Portal hemodynamics in chronic portal-systemic encephalopathy

    International Nuclear Information System (INIS)

    Takashi, Motohide; Igarashi, Masahiko; Hino, Shinichi; Takayasu, Kenichi; Goto, Nobuaki; Musha, Hirotaka; Ohnishi, Kunihiko; Okuda, Kunio

    1985-01-01

    A portal hemodynamic study was made in 7 consecutive patients with chronic portal-systemic encephalopathy by percutaneous transhepatic catheterization of the portal vein and injecting contrast medium into the superior mesenteric vein or by superior mesenteric arterial portography in comparison with patients without encephalopathy studied by percutaneous catheterization of these veins. It is suggested that chronic portal-systemic encephalopathy is a result of a large collateral route shunting a large proportion of the superior mesenteric venous blood into systemic circulation, and that development of such collaterals precludes formation of large esophageal varices. (Auth.)

  5. Combined Rex-bypass shunt with pericardial devascularization alleviated prehepatic portal hypertension caused by cavernomatous transformation of portal vein.

    Science.gov (United States)

    Wang, Ruo-Yi; Wang, Jun-Feng; Liu, Qian; Ma, Nan; Chen, Wei-Xiu; Li, Jin-Liang

    2017-09-01

    To evaluate the effects of combined Rex-bypass shunt and pericardial devascularization on prehepatic portal hypertension secondary to cavernomatous transformation of portal vein (CTPV). Forty-two patients aged from 3 years to 49 years (divided into 3 groups), 26 cases male and 16 female, with prehepatic vascular hepertention were treated with Rex-bypass shunt combined with pericardial devascularization. In each patient, preoperative assessment included ultrasound and computed tomographic angiography of the portal vein and blood analysis. The procedure was Rex-bypass shunt (with or without graft), and patients with moderate or severe gastroesophageal varices required additional paraesophagogastric devascularization. Splenectomy or subtotal splenectomy was performed if combined hypersplenism co-existed. All data were analyzed retrospectively. No intraoperative death occurred, blood routine analysis improved (P portal vein (LPV) significantly increased, the esophageal and gastric varices significantly relieved in 34 patients (P portal hypertension caused by CTPV.

  6. Quantitative vs. subjective portal verification using digital portal images.

    Science.gov (United States)

    Bissett, R; Leszczynski, K; Loose, S; Boyko, S; Dunscombe, P

    1996-01-15

    as unacceptable, in terms of the field placement, exhibited significantly higher (p portals rated as unacceptable by two of the oncologists. From the parameters that were used to quantify the degree of conformity between the prescription and treatment fields, the translational error in the transverse direction correlated best with the oncologists' assessments on the field placement. Field coverage and translational error in the cranio-caudal direction correlated well with assessments of only two out of the four participating oncologists. This can be explained by the fact that for the majority of treatment sites included in the study the positioning of field borders was more critical for the transverse direction. A conclusion for the design of future quantitative and automated on-line portal verification systems is that they will have to model different perceived significances of different types of localization errors intrinsic to oncologist evaluation of portal images.

  7. Evaluation of patients with portal hypertension using Tc-99m-Sn Colloid scintigraphy

    International Nuclear Information System (INIS)

    Khan, H.A.

    1990-01-01

    Thirty seven cases of portal hypertension with endoscopically proven esophageal varieces underwent liver biopsy to determine the aetiology of portal hypertension. From which 19 had cirrhosis and 18 Idiopathic Portal Hypertension. Tc-99m-Sn colloid static and dynamic scintigraphy of the liver and spleen was performed in these patients. Apart from the calculation of ratio of area (A L/S), ratio of integral (I L/S) were also computed to see if these could be used to differentiate cirrhosis from IPH. Significant difference was noted in the ratio of the area in patients and controls, but the ratios of the integral (IL/S) and the slope of the integral (SIL/S) were not only significantly different in the patients and controls but also in the two groups of patients. The sensitivity of this test when compared with histology was 58% for cirrhosis and IPH but when compared with clinical diagnosis it was 76% for cirrhosis and 62% for IPH group. Therefore, by using the above mentioned technique in the routine study of liver scintigraphy in patients with portal hypertension, the added information obtained can be used to further differentiate the cirrhotic and non cirrhotic group of portal hypertensives. (author)

  8. Radioisotopic flow scanning for portal blood flow and portal hypertension

    International Nuclear Information System (INIS)

    Hesdorffer, C.S.; Bezwoda, W.R.; Danilewitz, M.D.; Esser, J.D.; Tobias, M.

    1987-01-01

    The use of a simple, noninvasive, isotope scanning technique for the determination of relative portal blood flow and detection of portal hypertension is described. Using this technique the presence of portal hypertension was demonstrated in seven of nine patients known to have elevated portal venous pressure. By contrast, esophageal varices were demonstrated in only five of these patients, illustrating the potential value of the method. Furthermore, this technique has been adapted to the study of portal blood flow in patients with myeloproliferative disorders with splenomegaly but without disturbances in hepatic architecture. Results demonstrate that the high relative splenic flow resulting from the presence of splenomegaly may in turn be associated with elevated relative portal blood flow and portal hypertension. The theoretic reasons for the development of flow-related portal hypertension and its relationship to splenic blood flow are discussed

  9. Portal hyperflow in patients with hepatosplenic mansonic schistosomiasis Hiperfluxo portal na forma hepatosplênica da esquistossomose mansônica

    Directory of Open Access Journals (Sweden)

    Roberto de Cleva

    2004-02-01

    Full Text Available PURPOSE: The purpose of this study was to assess portal hemodynamics in patients with portal hypertension due to hepatosplenic schistosomiasis as well as to assess the contribution of splanchnic hyperflow to the pathophysiology of the portal hypertension. METHODS: Sixteen patients with schistosomal portal hypertension and previous history of upper digestive bleeding due to esophageal varices rupture underwent elective esophagogastric devascularization and splenectomy and were prospectively studied. All patients underwent intraoperative invasive hemodynamic portal monitoring with a 4F-thermodilution catheter. The intraoperative portal hemodynamic assessment was conducted after laparotomy (initial and after esophagogastric devascularization (final. RESULTS: The initial portal pressure was elevated (mean 28.5 ± 4.5 mm Hg, and a significant drop of 25% was observed at the end of the surgery (21.9 ± 4.9 mm Hg. The initial portal flow was elevated (mean 1766.9 ± 686.6 mL/min. A significant fall (42% occurred at the end of the surgical procedure (1025.62 ± 338.7 mL/min. Fourteen patients (87.5% presented a portal flow of more than 1200 mL/min, and in 5 cases, values greater than 2000 mL/min were observed. CONCLUSIONS: Esophagogastric devascularization and splenectomy promote a significant reduction of the elevated portal pressure and flow in schistosomal portal hypertension. These data favor the hypothesis of portal hyperflow in the physiopathology of portal hypertension of schistosomiasis.OBJETIVOS: o objetivo do presente estudo é estudar a hemodinâmica portal em pacientes com hipertensão portal secundária a forma hepatoesplênica da esquistossomose e avaliar a contribuição do hiperfluxo esplênico na sua fisiopatologia CASUÍSTICA E MÉTODOS: Foram estudados prospectivamente 16 pacientes portadores de hipertensão portal secundária à forma hepatoesplênica da esquistossomose mansônica com indicação de tratamento cirúrgico. Todos foram

  10. Patient portals and broadband internet inequality.

    Science.gov (United States)

    Perzynski, Adam T; Roach, Mary Joan; Shick, Sarah; Callahan, Bill; Gunzler, Douglas; Cebul, Randall; Kaelber, David C; Huml, Anne; Thornton, John Daryl; Einstadter, Douglas

    2017-09-01

    Patient portals have shown potential for increasing health care quality and efficiency. Internet access and other factors influencing patient portal use could worsen health disparities. Observational study of adults with 1 or more visits to the outpatient clinics of an urban public health care system from 2012 to 2015. We used mixed effects logistic regression to evaluate the association between broadband internet access and (1) patient portal initiation (whether a patient logged in at least 1 time) and (2) messaging, controlling for demographic and neighborhood characteristics. There were 243 248 adults with 1 or more visits during 2012-2015 and 70 835 (29.1%) initiated portal use. Portal initiation was 34.1% for whites, 23.4% for blacks, and 23.8% for Hispanics, and was lower for Medicaid (26.5%), Medicare (23.4%), and uninsured patients (17.4%) than commercially insured patients (39.3%). In multivariate analysis, both initiation of portal use (odds ratio [OR] = 1.24 per quintile, 95% confidence interval [CI], 1.23-1.24, P  internet access. The majority of adults with outpatient visits to a large urban health care system did not use the patient portal, and initiation of use was lower for racial and ethnic minorities, persons of lower socioeconomic status, and those without neighborhood broadband internet access. These results suggest the emergence of a digital divide in patient portal use. Given the scale of investment in patient portals and other internet-dependent health information technologies, efforts are urgently needed to address this growing inequality. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  11. Extrahepatic Portal Hypertension following Liver Transplantation: a Rare but Challenging Problem

    Directory of Open Access Journals (Sweden)

    B. Malassagne

    1998-01-01

    Full Text Available This study reports our experience of 8 cases of extrahepatic portal hypertension after 273 orthotopic liver transplantations in 244 adult patients over a 10- year period. The main clinical feature was ascites, and the life-threatening complication was variceal bleeding. Extrahepatic portal hypertension was caused by portal vein stenosis in 6 patients, and left-sided portal hypertension in 2 patients after inadventent ligation of portal venous tributaries or portasystemic shunts. All patients with portal vein stenosis had complete relief of portal hypertension after percutaneous transhepatic venoplasty (n=4 or surgical reconstruction (n=2, after a median follow-up of 33 (range: 6–62 months. Of the 2 patients with left-sided portal hypertension, one died after splenectomy and one rebled 6 months after left colectomy. This study suggests that extrahepatic portal hypertension is a series complication after liver transplantation that could be prevented by meticulous portal anastomosis and closure of portal tributaries or portasystemic shunts to improve the portal venous flow. However, any ligation has to be performed under ultrasound guidance to avoid inadventent venous ligations.

  12. Portal hypertension: a review of portosystemic collateral pathways and endovascular interventions

    International Nuclear Information System (INIS)

    Pillai, A.K.; Andring, B.; Patel, A.; Trimmer, C.; Kalva, S.P.

    2015-01-01

    The portal vein is formed at the confluence of the splenic and superior mesenteric vein behind the head of the pancreas. Normal blood pressure within the portal system varies between 5 and 10 mmHg. Portal hypertension is defined when the gradient between the portal and systemic venous blood pressure exceeds 5 mmHg. The most common cause of portal hypertension is cirrhosis. In cirrhosis, portal hypertension develops due to extensive fibrosis within the liver parenchyma causing increased vascular resistance. In addition, the inability of the liver to metabolise certain vasodilators leads to hyperdynamic splanchnic circulation resulting in increased portal blood flow. Decompression of the portal pressure is achieved by formation of portosystemic collaterals. In this review, we will discuss the pathophysiology, anatomy, and imaging findings of spontaneous portosystemic collaterals and clinical manifestations of portal hypertension with emphasis on the role of interventional radiology in the management of complications related to portal hypertension

  13. Portal Hypertension

    Science.gov (United States)

    ... Overview of Gallbladder Cancer Additional Content Medical News Portal Hypertension By Steven K. Herrine, MD, Professor of Medicine, ... Liver Hepatic Encephalopathy Jaundice in Adults Liver Failure Portal Hypertension Portal hypertension is abnormally high blood pressure in ...

  14. Percutaneous transhepatic stent placement in the management of portal venous stenosis after curative surgery for pancreatic and biliary neoplasms.

    Science.gov (United States)

    Kim, Kyung Rae; Ko, Gi-Young; Sung, Kyu-Bo; Yoon, Hyun-Ki

    2011-04-01

    The purpose of this study was to evaluate the efficacy and safety of stent placement in the management of portal venous stenosis after curative surgery for pancreatic and biliary neoplasms. From September 1995 to April 2007, percutaneous transhepatic portal venous stent placement was attempted in 19 patients with postoperative portal venous stenosis. Portal venous stenosis was a complication of surgery in 11 patients and caused by tumor recurrence in eight patients. The clinical manifestations were ascites, hematochezia, melena, esophageal varices, and abnormal liver function. Stents were placed in the stenotic or occluded lesions after percutaneous transhepatic portography. Technical and clinical success, stent patency, and complications were evaluated. Stent placement was successful in 18 patients (technical success rate, 95%). Clinical manifestations improved in 16 patients (clinical success rate, 84%). The mean patency period among the 18 patients with technical success was 21.3 ± 23.2 months. The mean patency period of the benign stenosis group (30.1 ± 25.6 months) was longer than that of the tumor recurrence group (7.3 ± 7.7 months), and the difference was statistically significant (p = 0.038). There were two cases of a minor complication (transient fever) and three cases of major complications (septicemia, liver abscess, and acute portal venous thrombosis). Percutaneous transhepatic stent placement can be safe and effective in relieving portal venous stenosis after curative surgery for pancreatic and biliary neoplasms. Patients with benign stenosis had more favorable results than did those with tumor recurrence.

  15. Sustained virologic response to interferon-free therapies ameliorates HCV-induced portal hypertension.

    Science.gov (United States)

    Mandorfer, Mattias; Kozbial, Karin; Schwabl, Philipp; Freissmuth, Clarissa; Schwarzer, Rémy; Stern, Rafael; Chromy, David; Stättermayer, Albert Friedrich; Reiberger, Thomas; Beinhardt, Sandra; Sieghart, Wolfgang; Trauner, Michael; Hofer, Harald; Ferlitsch, Arnulf; Ferenci, Peter; Peck-Radosavljevic, Markus

    2016-10-01

    We aimed to investigate the impact of sustained virologic response (SVR) to interferon (IFN)-free therapies on portal hypertension in patients with paired hepatic venous pressure gradient (HVPG) measurements. One hundred and four patients with portal hypertension (HVPG ⩾6mmHg) who underwent HVPG and liver stiffness measurement before IFN-free therapy (baseline [BL]) were retrospectively studied. Among 100 patients who achieved SVR, 60 patients underwent HVPG and transient elastography (TE) after antiviral therapy (follow-up [FU]). SVR to IFN-free therapies significantly decreased HVPG across all BL HVPG strata: 6-9mmHg (BL: 7.37±0.28 vs. FU: 5.11±0.38mmHg; -2.26±0.42mmHg; pportal hypertension across all BL HVPG strata. However, changes in HVPG seemed to be more heterogeneous among patients with BL HVPG of ⩾16mmHg and a HVPG decrease was less likely in patients with more advanced liver dysfunction. TE might be useful for the non-invasive evaluation of portal hypertension after SVR. We investigated the impact of curing hepatitis C using novel interferon-free treatments on portal hypertension, which drives the development of liver-related complications and mortality. Cure of hepatitis C decreased portal pressure, but a decrease was less likely among patients with more pronounced hepatic dysfunction. Transient elastography, which is commonly used for the non-invasive staging of liver disease, might identify patients without clinically significant portal hypertension after successful treatment. Copyright © 2016 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  16. Impact and user satisfaction of a clinical information portal embedded in an electronic health record.

    Science.gov (United States)

    Tannery, Nancy H; Epstein, Barbara A; Wessel, Charles B; Yarger, Frances; LaDue, John; Klem, Mary Lou

    2011-01-01

    In 2008, a clinical information tool was developed and embedded in the electronic health record system of an academic medical center. In 2009, the initial information tool, Clinical-e, was superseded by a portal called Clinical Focus, with a single search box enabling a federated search of selected online information resources. To measure the usefulness and impact of Clinical Focus, a survey was used to gather feedback about users' experience with this clinical resource. The survey determined what type of clinicians were using this tool and assessed user satisfaction and perceived impact on patient care decision making. Initial survey results suggest the majority of respondents found Clinical Focus easy to navigate, the content easy to read, and the retrieved information relevant and complete. The majority would recommend Clinical Focus to their colleagues. Results indicate that this tool is a promising area for future development.

  17. An analysis of splenoportographic findings in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Eun Mi; Moon, Sook Ran; Kim, Han Suk [National Medical Center, Seoul (Korea, Republic of); Park, Soo Soung [College of Medicine, Chung Ang University, Seoul (Korea, Republic of)

    1983-12-15

    Splenoportography has been proved as a useful method for the evaluation of circulatory disturbances in portal hypertension. Authors analyzed the various aspects of these disturbance on splenoportography in 22 cases that was performed under the clinical suspicion of portal hypertension during recent 6 years, from May, 1976 to July 1982 at the Department of Radiology, National Medical Center. The results were as follows: 1. Liver cirrhosis was the most frequent cause of intrahepatic obstruction type in portal hypertension (86%). 2. The portal pressure was more than 400 mmH{sub 2}0 in 67% of the cases (range; 300-540 mmH{sub 2}0). 3. In the majority of the cases, the higher the portal pressure was, the more dilated splenic and portal veins were. The diameter of portal vein was more than 15 mm in 79%, more than 21 mm in 47% of the cases (range; 10-26 mm). The diameter of splenic vein was more than 15 mm in 48% of the cases (range; 7-23 mm). Especially the diameter of splenic vein was larger than that of portal vein in 20% of the cases. 4. There was no definite correlation between the development of collateral circulation and the diameter of splenic and portal veins. 5. The filling of collateral circulation was definite sign of portal hypertension, though not regular. In portal hypertension, the collateral circulation was formed via coronary vein (91%), short gastric vein (64%), inferior mesenteric vein (36%). 6. Splenic-hilum time was delayed in 64% of the cases. Intrahepatic portal vein emptying time was more than 6 seconds in all the cases. 7. Most of the cases (91%) could be diagnosed as portal hypertension with vasculogram and hepatogram.

  18. An analysis of splenoportographic findings in portal hypertension

    International Nuclear Information System (INIS)

    Jung, Eun Mi; Moon, Sook Ran; Kim, Han Suk; Park, Soo Soung

    1983-01-01

    Splenoportography has been proved as a useful method for the evaluation of circulatory disturbances in portal hypertension. Authors analyzed the various aspects of these disturbance on splenoportography in 22 cases that was performed under the clinical suspicion of portal hypertension during recent 6 years, from May, 1976 to July 1982 at the Department of Radiology, National Medical Center. The results were as follows: 1. Liver cirrhosis was the most frequent cause of intrahepatic obstruction type in portal hypertension (86%). 2. The portal pressure was more than 400 mmH 2 0 in 67% of the cases (range; 300-540 mmH 2 0). 3. In the majority of the cases, the higher the portal pressure was, the more dilated splenic and portal veins were. The diameter of portal vein was more than 15 mm in 79%, more than 21 mm in 47% of the cases (range; 10-26 mm). The diameter of splenic vein was more than 15 mm in 48% of the cases (range; 7-23 mm). Especially the diameter of splenic vein was larger than that of portal vein in 20% of the cases. 4. There was no definite correlation between the development of collateral circulation and the diameter of splenic and portal veins. 5. The filling of collateral circulation was definite sign of portal hypertension, though not regular. In portal hypertension, the collateral circulation was formed via coronary vein (91%), short gastric vein (64%), inferior mesenteric vein (36%). 6. Splenic-hilum time was delayed in 64% of the cases. Intrahepatic portal vein emptying time was more than 6 seconds in all the cases. 7. Most of the cases (91%) could be diagnosed as portal hypertension with vasculogram and hepatogram

  19. Idiopathic noncirrhotic portal hypertension in dogs: 33 cases (1982-1998).

    Science.gov (United States)

    Bunch, S E; Johnson, S E; Cullen, J M

    2001-02-01

    To describe clinical signs, diagnostic findings, and outcome in dogs with idiopathic intrahepatic portal hypertension. Retrospective study. 33 dogs. Medical records of dogs with portal hypertension of intra-abdominal origin were reviewed. Dogs with intra-abdominal portal hypertension of vascular causes or with hepatic histopathologic changes consistent with severe diffuse hepatobiliary disease were excluded. History and results of physical examination, clinicopathologic tests, diagnostic imaging studies, histologic examination, and treatment were summarized. Outcome was determined in 26 dogs. Dogs were referred most often because of ascites, intermittent vomiting or diarrhea, and polydipsia of several months' duration. Microcytosis, high serum alkaline phosphatase and alanine transaminase activities, hepatic dysfunction, urine specific gravity anastomoses were the major findings of diagnostic imaging. Hepatic histopathologic changes were consistent with idiopathic noncirrhotic portal hypertension and were indistinguishable from those of dogs with surgically created portocaval anastomosis. Outcome was determined for 19 dogs released from hospital; 13 dogs remained healthy with mostly palliative treatment for periods of 5 months to 9 years. The clinical signs, clinicopathologic test results, portal pressure, and gross appearance of the liver of dogs with idiopathic noncirrhotic portal hypertension may be identical to those of dogs with cirrhosis; therefore liver biopsy is crucial. Because the prognosis for idiopathic noncirrhotic portal hypertension is generally favorable, owners of affected dogs should be discouraged from choosing euthanasia.

  20. Blood in the gastric lumen increases splanchnic blood flow and portal pressure in portal-hypertensive rats.

    Science.gov (United States)

    Chen, L; Groszmann, R J

    1996-10-01

    In portal-hypertensive humans, portal blood flow and pressure increase after a meal. These hemodynamic changes may increase variceal rupture risk. The aim of this study was to determine whether blood in the stomach lumen increases splanchnic flow and portal pressure (PP) in portal-hypertensive rats. superior mesenteric artery flow and PP were measured in conscious, unrestrained, fasted partial portal vein-ligated rats with chronically implanted Doppler flow probes or portal vein catheters before and after gavage with heparinized, warmed blood from donor rats, air, standard meal, or empty tube. Percentage of changes in flow and pressure from baseline were significantly greater after gavage with blood (an increase of 22.6% +/- 3.5% and an increase of 16.4% +/- 3.1%, respectively) than empty tube (an increase of 3.4% +/- 0.6% and a decrease of 5.4% +/- 3.5%, respectively) (P empty tube (P calories probably contributes to these hemodynamic changes. In patients with variceal hemorrhage, blood in the stomach may increase the risk of persistent variceal bleeding or rebleeding.

  1. Índice de congestão portal e a ocorrência de trombose portal pós-dape Portal congestion and thrombosis after EDS

    Directory of Open Access Journals (Sweden)

    Fabio Gonçalves Ferreira

    2005-08-01

    portal vein were analyzed: diameter, area, mean blood flow velocity and blood flow, whereupon the congestion index was calculated. RESULTS: The diameter, area and blood flow of the portal vein were greater in group B (mean of 1.52 cm; 1.77 cm² and 2533.12 ml / min than in group A (mean of 1.33 cm; 1.44 cm² and 1609.03 ml / min with p = 0.03; 0.03 and 0.04 respectively. Difference of the congestion index was not statistically significant between the two groups (p = 0.07. CONCLUSIONS: The portal vein congestion index at the preoperative of EDS estimated by Doppler ultrasound was not predictive of portal vein thrombosis in the postoperative of patients with portal hypertension due to schistosomiasis.

  2. Digitalization and networking of analog simulators and portal images.

    Science.gov (United States)

    Pesznyák, Csilla; Zaránd, Pál; Mayer, Arpád

    2007-03-01

    Many departments have analog simulators and irradiation facilities (especially cobalt units) without electronic portal imaging. Import of the images into the R&V (Record & Verify) system is required. Simulator images are grabbed while portal films scanned by using a laser scanner and both converted into DICOM RT (Digital Imaging and Communications in Medicine Radiotherapy) images. Image intensifier output of a simulator and portal films are converted to DICOM RT images and used in clinical practice. The simulator software was developed in cooperation at the authors' hospital. The digitalization of analog simulators is a valuable updating in clinical use replacing screen-film technique. Film scanning and digitalization permit the electronic archiving of films. Conversion into DICOM RT images is a precondition of importing to the R&V system.

  3. Transjugular Intrahepatic Portosystemic Shunt for Portal Hypertension in Hepatocellular Carcinoma with Portal Vein Tumor Thrombus.

    Science.gov (United States)

    Qiu, Bin; Li, Kai; Dong, Xiaoqun; Liu, Fu-Quan

    2017-09-01

    In patients with hepatocellular carcinoma (HCC), limited therapeutic options are available for portal hypertension resulted from portal vein tumor thrombus (PVTT). We aimed to determine safety and efficacy of TIPS for treatment of symptomatic portal hypertension in HCC with PVTT. We evaluated clinical characteristics of 95 patients with HCC and PVTT out of 992 patients who underwent TIPS. The primary endpoints included success rate, procedural mortality, serious complications, decrease in portosystemic pressure gradient, and symptom relief. The secondary endpoints included recurrence of portal hypertension, overall survival, adverse events related to treatments for HCC, and quality of life measured by Karnofsky Performance Status Scale (KPS). Success rate of TIPS was 95.8% (91/95), with procedural mortality of 1.1%. Serious complications related to TIPS procedure occurred in 2.1% (2/95) of patients. The symptoms of portal hypertension were well relieved. Variceal bleeding was successfully controlled and terminated in 100% of patients, with a recurrence rate of 39.2% in 12 months. Refractory ascites/hydrothorax was controlled partially or completely in 92.9% of patients during 1 month after TIPS, with a recurrence rate of 17.9% in 12 months. Survival rate at 6, 12, 24, and 36 months was 75.8, 52.7, 26.4, and 3.3%, respectively. No unexpected adverse event related to treatments for HCC was observed. The KPS score was 49 ± 4.5 and 63 ± 4.7 before and 1 month after TIPS, respectively (p portal hypertension in HCC with PVTT.

  4. Antibody Portal | Office of Cancer Clinical Proteomics Research

    Science.gov (United States)

    Central to reproducibility in biomedical research is being able to use well-characterized and defined reagents. The CPTAC Antibody Portal serves as a National Cancer Institute (NCI) community resource that provides access to a large number of standardized renewable affinity reagents (to cancer-associated targets) and accompanying characterization data.

  5. Transjugular intrahepatic portosystemic shunt in patients with active variceal bleeding due to portal hypertension and portal vein thrombosis

    International Nuclear Information System (INIS)

    Shin, Hyun Woong; Ryeom, Hun Kyu; Lee, Sang Kwon; Lee, Jong Min; Kim, Young Sun; Suh, Kyung Jin; Kim, Tae Hun; Kim, Yong Joo

    1997-01-01

    To evaluate the feasibility and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) in patients with active variceal bleeding due to liver cirrhosis and pre-existing portal vein thrombosis. Of a total of 123 patients who underwent TIPS, 14 patients with intractable variceal bleeding due to portal hypertension and portal vein thrombosis were included in this study. Noncavernomatous portal vein occlusion was seen in eight patients, and complete portal vein occlusion with cavernomatous trans-formation in six. For all patients, the methods used for TIPS placement were the same as those used in patients with patents portal veins. In seven of eight patients with noncavernomatous occlusion, right hepatic vein-right portal vein shunting was performed; in one with knoncavernomatous occlusion, a shunt was created between the right hepatic and left portal vein. In five of six patients with cavernomatous occlusion, the right hepatic and main portal vein were connected via a collateral vein. The procedures were technically successful in all except one patient. Immediate hemostatis was achieved after all technically successful procedures, and no significant complications were encountered. Minor complications were noted in six patients (three biliary tree punctures, one transperitoneal puncture, one splenic vein perforation, one hepatic subcapsular hematoma). TIPS is a technically feasible and hemodynamically effective procedure, even in patients with active variceal bleeding due to cirrhosis and complete portal vein occlusion

  6. Improving diabetes management with a patient portal: a qualitative study of diabetes self-management portal.

    Science.gov (United States)

    Urowitz, Sara; Wiljer, David; Dupak, Kourtney; Kuehner, Zachary; Leonard, Kevin; Lovrics, Emily; Picton, Peter; Seto, Emily; Cafazzo, Joe

    2012-11-30

    Effective management and care of diabetes is crucial to reducing associated risks such as heart disease and kidney failure. With increasing access and use of the Internet, online chronic disease management is being explored as a means of providing patients with support and the necessary tools to monitor and manage their disease. The objective of our study was to evaluate the experience of patients and providers using an online diabetes management portal for patients. Participants were recruited from a large sample population of 887 for a follow-up questionnaire to be completed after 6 months of using the patient portal. Participants were presented with the option to participate in an additional interview and, if the participant agreed, a time and date was scheduled for the interview. A 5-item, open-ended questionnaire was used to capture providers' opinions of the patient portal. Providers included general practitioners (GPs), nurses, nurse practitioners (NPs), dieticians, diabetes educators (DECs), and other clinical staff. A total of 854 patients were consented for the questionnaire. Seventeen (8 male, 9 female) patients agreed to participate in a telephone interview. Sixty-four health care providers completed the five open-ended questions; however, an average of 48.2 responses were recorded per question. Four major themes were identified and will be discussed in this paper. These themes have been classified as: facilitators of disease management, barriers to portal use, patient-provider communication and relationship, and recommendations for portal improvements. This qualitative study shows that online chronic disease management portals increase patient access to information and engagement in their health care, but improvements in the portal itself may improve usability and reduce attrition. Furthermore, this study identifies a grey area that exists in the roles that GPs and AHPs should play in the facilitation of online disease management.

  7. Patterns of access to the Guías de Práctica Clínica (Clinical Practice Guidelines Web Portal in Colombia

    Directory of Open Access Journals (Sweden)

    Fernando Suárez-Obando

    2016-10-01

    Full Text Available Introduction: Colombian clinical practice guidelines for health care are published in the Web Portal of the Ministry of Health and Social Protection. Objective: To analyze the traffic of the clinical guidelines portal through web consultation metrics. Materials and methods: The website traffic analysis was performed over a period of 20 months using Google Analytics and Megalytic. Results: 190 115 users logged in, and 125 475 of them (≈66% were first-time visitors, while 63 118 (≈33% were repeated users. 126 994 users visited 608 745 pages, with an average of 3.2 pages per session, query time of 3.45 minutes per visit and average rebound rate of 46.74%. 40% of users interacted with at least three pages and 40% left the site without interacting with a second page. The sessions originated in Colombia, Mexico, Peru and Spain; the first country represented 169 666 visits and Bogotá D.C. recorded the highest number of visits (32%, followed by Medellín (12.3%, Cali (8.3%, Barranquilla (4.1% and Bucaramanga (3.3%, for a total of 60% of the traffic. The most visited guides were handling pregnancy and infection of the urogenital tract. Conclusions: The portal had an acceptable traffic during the first 20 months of operation. An innovative portal that improves the dissemination of the guides must remain active.

  8. Portal hypertension: a review of portosystemic collateral pathways and endovascular interventions.

    Science.gov (United States)

    Pillai, A K; Andring, B; Patel, A; Trimmer, C; Kalva, S P

    2015-10-01

    The portal vein is formed at the confluence of the splenic and superior mesenteric vein behind the head of the pancreas. Normal blood pressure within the portal system varies between 5 and 10 mmHg. Portal hypertension is defined when the gradient between the portal and systemic venous blood pressure exceeds 5 mmHg. The most common cause of portal hypertension is cirrhosis. In cirrhosis, portal hypertension develops due to extensive fibrosis within the liver parenchyma causing increased vascular resistance. In addition, the inability of the liver to metabolise certain vasodilators leads to hyperdynamic splanchnic circulation resulting in increased portal blood flow. Decompression of the portal pressure is achieved by formation of portosystemic collaterals. In this review, we will discuss the pathophysiology, anatomy, and imaging findings of spontaneous portosystemic collaterals and clinical manifestations of portal hypertension with emphasis on the role of interventional radiology in the management of complications related to portal hypertension. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Idiopathic portal hypertension

    International Nuclear Information System (INIS)

    Han, Tae Kyun; Ryu, Dae Sik; Kim, Heung Chul; Hur, Hun; Eom, Kyeung Tae; Namkung, Sook; Park, Man Soo; Hwang, Woo Chul; Lee, Kwan Seop

    1996-01-01

    To describe the radiologic findings of idiopathic portal hypertension and to find the points of differentiation between idiopathic portal hypertension and liver cirrhosis. Four portograms in five patients who for four years had suffered from pathologically confirmed idiopathic portal hypertension were retrospectively analyzed and compared with a portogram obtained from a control subject with liver cirrhosis. Portographic finding s of idiopathic portal hypertension were paucity of medium-sized portal branches, irregular and obtuse-angled division of peripheral branches, abrupt interruption and an avascular area beneath the liver margin. A portogram of idiopathic portal hypertension may be useful in differentiation this and liver cirrhosis

  10. Systemic thrombolysis of portal vein thrombosis in cirrhotic patients: a pilot study.

    Science.gov (United States)

    De Santis, Adriano; Moscatelli, Rosanna; Catalano, Carlo; Iannetti, Antonio; Gigliotti, Francesca; Cristofari, Francesca; Trapani, Silvia; Attili, Adolfo F

    2010-06-01

    Portal vein thrombosis is a frequent complication in liver cirrhosis. Encouraging reports of systemic thrombolysis in non-cirrhotic patients suffering from acute portal vein thrombosis led us to start a pilot study on the efficacy and safety of systemic low dose recombinant tissue plasminogen activator (Actilyse, Boheringer Ingelheim, Florence, Italy). Nine cirrhotic patients (6 males and 3 females) with recent portal vein thrombosis were enrolled. Exclusion criteria were portal cavernomatosis, recent (30 days) surgery, active bleeding, hepatocellular carcinoma and cancer in other sites. All cases were treated for a maximum of 7 days by continuous i.v. infusion of 0.25mg/kg/die of r-tPA plus subcutaneous low molecular weight heparin. Efficacy was evaluated by colour doppler sonography monitoring and confirmed by contrast enhanced computerized tomography. The combined r-tPA/LMWH treatment was well tolerated without clinically significant side effects. Complete resolution of thrombosis occurred in 4 cases, partial regression in 4 and none in 1. Retreatment of a complete recurrence in 1 patient was successful. Variceal pressure dropped from 30.7+/-4.5 mmHg to 21.2+/-6.6 mmHg (p=0.012). Our preliminary data demonstrate that thrombolytic treatment of recent portal vein thrombosis with i.v. r-tPA and LMWH in patients with cirrhosis appears to be safe and effective and can significantly reduce pressure in oesophageal varices. Copyright 2009 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  11. Electronic portal imaging devices

    International Nuclear Information System (INIS)

    Lief, Eugene

    2008-01-01

    The topics discussed include, among others, the following: Role of portal imaging; Port films vs. EPID; Image guidance: Elekta volume view; Delivery verification; Automation tasks of portal imaging; Types of portal imaging (Fluorescent screen, mirror, and CCD camera-based imaging; Liquid ion chamber imaging; Amorpho-silicon portal imagers; Fluoroscopic portal imaging; Kodak CR reader; and Other types of portal imaging devices); QA of EPID; and Portal dosimetry (P.A.)

  12. Portal Annular Pancreas

    Science.gov (United States)

    Harnoss, Jonathan M.; Harnoss, Julian C.; Diener, Markus K.; Contin, Pietro; Ulrich, Alexis B.; Büchler, Markus W.; Schmitz-Winnenthal, Friedrich H.

    2014-01-01

    Abstract Portal annular pancreas (PAP) is an asymptomatic congenital pancreas anomaly, in which portal and/or mesenteric veins are encased by pancreas tissue. The aim of the study was to determine the role of PAP in pancreatic surgery as well as its management and potential complication, specifically, postoperative pancreatic fistula (POPF). On the basis of a case report, the MEDLINE and ISI Web of Science databases were systematically reviewed up to September 2012. All articles describing a case of PAP were considered. In summary, 21 studies with 59 cases were included. The overall prevalence of PAP was 2.4% and the patients' mean (SD) age was 55.9 (16.2) years. The POPF rate in patients with PAP (12 pancreaticoduodenectomies and 3 distal pancreatectomies) was 46.7% (in accordance with the definition of the International Study Group of Pancreatic Surgery). Portal annular pancreas is a quite unattended pancreatic variant with high prevalence and therefore still remains a clinical challenge to avoid postoperative complications. To decrease the risk for POPF, attentive preoperative diagnostics should also focus on PAP. In pancreaticoduodenectomy, a shift of the resection plane to the pancreas tail should be considered; in extensive pancreatectomy, coverage of the pancreatic remnant by the falciform ligament could be a treatment option. PMID:25207658

  13. 29 CFR 785.24 - Principles noted in Portal-to-Portal Bulletin.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Principles noted in Portal-to-Portal Bulletin. 785.24 Section 785.24 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR... of Principles Preparatory and Concluding Activities § 785.24 Principles noted in Portal-to-Portal...

  14. Factors Affecting Faculty Web Portal Usability

    Science.gov (United States)

    Bringula, Rex P.; Basa, Roselle S.

    2011-01-01

    The study investigated the factors that might significantly affect web portal usability. Results of the study were intended to serve as inputs for faculty web portal development of the University of the East-Manila. Descriptive statistics utilized questionnaire data from 82 faculty members. The data showed that most of the respondents were…

  15. MR image-guided portal verification for brain treatment field

    International Nuclear Information System (INIS)

    Yin Fangfang; Gao Qinghuai; Xie Huchen; Nelson, Diana F.; Yu Yan; Kwok, W. Edmund; Totterman, Saara; Schell, Michael C.; Rubin, Philip

    1998-01-01

    Purpose: To investigate a method for the generation of digitally reconstructed radiographs directly from MR images (DRR-MRI) to guide a computerized portal verification procedure. Methods and Materials: Several major steps were developed to perform an MR image-guided portal verification procedure. Initially, a wavelet-based multiresolution adaptive thresholding method was used to segment the skin slice-by-slice in MR brain axial images. Some selected anatomical structures, such as target volume and critical organs, were then manually identified and were reassigned to relatively higher intensities. Interslice information was interpolated with a directional method to achieve comparable display resolution in three dimensions. Next, a ray-tracing method was used to generate a DRR-MRI image at the planned treatment position, and the ray tracing was simply performed on summation of voxels along the ray. The skin and its relative positions were also projected to the DRR-MRI and were used to guide the search of similar features in the portal image. A Canny edge detector was used to enhance the brain contour in both portal and simulation images. The skin in the brain portal image was then extracted using a knowledge-based searching technique. Finally, a Chamfer matching technique was used to correlate features between DRR-MRI and portal image. Results: The MR image-guided portal verification method was evaluated using a brain phantom case and a clinical patient case. Both DRR-CT and DRR-MRI were generated using CT and MR phantom images with the same beam orientation and then compared. The matching result indicated that the maximum deviation of internal structures was less than 1 mm. The segmented results for brain MR slice images indicated that a wavelet-based image segmentation technique provided a reasonable estimation for the brain skin. For the clinical patient case with a given portal field, the MR image-guided verification method provided an excellent match between

  16. Digitalization and networking of analog simulators and portal images

    Energy Technology Data Exchange (ETDEWEB)

    Pesznyak, C.; Zarand, P.; Mayer, A. [Uzsoki Hospital, Budapest (Hungary). Inst. of Oncoradiology

    2007-03-15

    Background: Many departments have analog simulators and irradiation facilities (especially cobalt units) without electronic portal imaging. Import of the images into the R and V (Record and Verify) system is required. Material and Methods: Simulator images are grabbed while portal films scanned by using a laser scanner and both converted into DICOM RT (Digital Imaging and Communications in Medicine Radiotherapy) images. Results: Image intensifier output of a simulator and portal films are converted to DICOM RT images and used in clinical practice. The simulator software was developed in cooperation at the authors' hospital. Conclusion: The digitalization of analog simulators is a valuable updating in clinical use replacing screen-film technique. Film scanning and digitalization permit the electronic archiving of films. Conversion into DICOM RT images is a precondition of importing to the R and V system. (orig.)

  17. Next Gen One Portal Usability Evaluation

    Science.gov (United States)

    Cross, E. V., III; Perera, J. S.; Hanson, A. M.; English, K.; Vu, L.; Amonette, W.

    2018-01-01

    Each exercise device on the International Space Station (ISS) has a unique, customized software system interface with unique layouts / hierarchy, and operational principles that require significant crew training. Furthermore, the software programs are not adaptable and provide no real-time feedback or motivation to enhance the exercise experience and/or prevent injuries. Additionally, the graphical user interfaces (GUI) of these systems present information through multiple layers resulting in difficulty navigating to the desired screens and functions. These limitations of current exercise device GUI's lead to increased crew time spent on initiating, loading, performing exercises, logging data and exiting the system. To address these limitations a Next Generation One Portal (NextGen One Portal) Crew Countermeasure System (CMS) was developed, which utilizes the latest industry guidelines in GUI designs to provide an intuitive ease of use approach (i.e., 80% of the functionality gained within 5-10 minutes of initial use without/limited formal training required). This is accomplished by providing a consistent interface using common software to reduce crew training, increase efficiency & user satisfaction while also reducing development & maintenance costs. Results from the usability evaluations showed the NextGen One Portal UI having greater efficiency, learnability, memorability, usability and overall user experience than the current Advanced Resistive Exercise Device (ARED) UI used by astronauts on ISS. Specifically, the design of the One-Portal UI as an app interface similar to those found on the Apple and Google's App Store, assisted many of the participants in grasping the concepts of the interface with minimum training. Although the NextGen One-Portal UI was shown to be an overall better interface, observations by the test facilitators noted specific exercise tasks appeared to have a significant impact on the NextGen One-Portal UI efficiency. Future updates to

  18. The VITRO Score (Von Willebrand Factor Antigen/Thrombocyte Ratio as a New Marker for Clinically Significant Portal Hypertension in Comparison to Other Non-Invasive Parameters of Fibrosis Including ELF Test.

    Directory of Open Access Journals (Sweden)

    Stephanie Hametner

    Full Text Available Clinically significant portal hypertension (CSPH, defined as hepatic venous pressure gradient (HVPG ≥10 mmHg, causes major complications. HVPG is not always available, so a non-invasive tool to diagnose CSPH would be useful. VWF-Ag can be used to diagnose. Using the VITRO score (the VWF-Ag/platelet ratio instead of VWF-Ag itself improves the diagnostic accuracy of detecting cirrhosis/ fibrosis in HCV patients.This study tested the diagnostic accuracy of VITRO score detecting CSPH compared to HVPG measurement.All patients underwent HVPG testing and were categorised as CSPH or no CSPH. The following patient data were determined: CPS, D'Amico stage, VITRO score, APRI and transient elastography (TE.The analysis included 236 patients; 170 (72% were male, and the median age was 57.9 (35.2-76.3; 95% CI. Disease aetiology included ALD (39.4%, HCV (23.4%, NASH (12.3%, other (8.1% and unknown (11.9%. The CPS showed 140 patients (59.3% with CPS A; 56 (23.7% with CPS B; and 18 (7.6% with CPS C. 136 patients (57.6% had compensated and 100 (42.4% had decompensated cirrhosis; 83.9% had HVPG ≥10 mmHg. The VWF-Ag and the VITRO score increased significantly with worsening HVPG categories (P<0.0001. ROC analysis was performed for the detection of CSPH and showed AUC values of 0.92 for TE, 0.86 for VITRO score, 0.79 for VWF-Ag, 0.68 for ELF and 0.62 for APRI.The VITRO score is an easy way to diagnose CSPH independently of CPS in routine clinical work and may improve the management of patients with cirrhosis.

  19. The accuracy of ultrasonography for the evaluation of portal hypertension in patients with cirrhosis: A systematic review

    International Nuclear Information System (INIS)

    Kim, Gaeun; Cho, Youn Zoo; Baik, Soon Koo; Kim, Moon Young; Hong, Won Ki; Kwon, Sang Ok

    2015-01-01

    Studies have presented conflicting results regarding the accuracy of ultrasonography (US) for diagnosing portal hypertension (PH). We sought to identify evidence in the literature regarding the accuracy of US for assessing PH in patients with liver cirrhosis. We conducted a systematic review by searching databases, including MEDLINE, EMBASE, and the Cochrane Library, for relevant studies. A total of 14 studies met our inclusion criteria. The US indices were obtained in the portal vein (n = 9), hepatic artery (n = 6), hepatic vein (HV) (n = 4) and other vessels. Using hepatic venous pressure gradient (HVPG) as the reference, the sensitivity (Se) and specificity (Sp) of the portal venous indices were 69-88% and 67-75%, respectively. The correlation coefficients between HVPG and the portal venous indices were approximately 0.296-0.8. No studies assess the Se and Sp of the hepatic arterial indices. The correlation between HVPG and the hepatic arterial indices ranged from 0.01 to 0.83. The Se and Sp of the hepatic venous indices were 75.9-77.8% and 81.8-100%, respectively. In particular, the Se and Sp of HV arrival time for clinically significant PH were 92.7% and 86.7%, respectively. A statistically significant correlation between HVPG and the hepatic venous indices was observed (0.545-0.649). Some US indices, such as HV, exhibited an increased accuracy for diagnosing PH. These indices may be useful in clinical practice for the detection of significant PH.

  20. The accuracy of ultrasonography for the evaluation of portal hypertension in patients with cirrhosis: A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gaeun; Cho, Youn Zoo; Baik, Soon Koo [College of Nursing, Research Institute for Nursing Science, Keimyung Univercity, Daegu (Korea, Republic of); Kim, Moon Young; Hong, Won Ki; Kwon, Sang Ok [Dept. of Internal Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju (Korea, Republic of)

    2015-04-15

    Studies have presented conflicting results regarding the accuracy of ultrasonography (US) for diagnosing portal hypertension (PH). We sought to identify evidence in the literature regarding the accuracy of US for assessing PH in patients with liver cirrhosis. We conducted a systematic review by searching databases, including MEDLINE, EMBASE, and the Cochrane Library, for relevant studies. A total of 14 studies met our inclusion criteria. The US indices were obtained in the portal vein (n = 9), hepatic artery (n = 6), hepatic vein (HV) (n = 4) and other vessels. Using hepatic venous pressure gradient (HVPG) as the reference, the sensitivity (Se) and specificity (Sp) of the portal venous indices were 69-88% and 67-75%, respectively. The correlation coefficients between HVPG and the portal venous indices were approximately 0.296-0.8. No studies assess the Se and Sp of the hepatic arterial indices. The correlation between HVPG and the hepatic arterial indices ranged from 0.01 to 0.83. The Se and Sp of the hepatic venous indices were 75.9-77.8% and 81.8-100%, respectively. In particular, the Se and Sp of HV arrival time for clinically significant PH were 92.7% and 86.7%, respectively. A statistically significant correlation between HVPG and the hepatic venous indices was observed (0.545-0.649). Some US indices, such as HV, exhibited an increased accuracy for diagnosing PH. These indices may be useful in clinical practice for the detection of significant PH.

  1. Rare Disease Video Portal

    OpenAIRE

    Sánchez Bocanegra, Carlos Luis

    2011-01-01

    Rare Disease Video Portal (RD Video) is a portal web where contains videos from Youtube including all details from 12 channels of Youtube. Rare Disease Video Portal (RD Video) es un portal web que contiene los vídeos de Youtube incluyendo todos los detalles de 12 canales de Youtube. Rare Disease Video Portal (RD Video) és un portal web que conté els vídeos de Youtube i que inclou tots els detalls de 12 Canals de Youtube.

  2. Establishment of a reversible model of prehepatic portal hypertension in rats.

    Science.gov (United States)

    Zhao, Xin; Dou, Jian; Gao, Qing-Jun

    2016-08-01

    The aim of the present study was to improve upon the traditional model of pre-hepatic portal hypertension in rats, and simulate the anhepatic phase of orthotopic liver transplantation without veno-venous bypass. A reversible model of portal hypertension was induced by portal vein ligation, with a label ring ligated along the portal vein. A total of 135 male Wistar rats were divided into three groups: i) Normal control (NC) group; ii) portal hypertensive control (PHTC) group; and iii) reperfusion (R) group. In the R group, rats with portal hypertension underwent simultaneous clamping of the portal triad and retrohepatic vena cava for 1 h, followed by removal of the clamps to enable blood reperfusion. Portal venography and portal vein pressure were recorded during the surgery. Arterial oxygen pressure (PaO 2 ), and alanine aminotransferase (ALT), aspartate aminotransferase (AST) and total bilirubin (TBil) levels were determined, and pathological changes of the liver were investigated by immunohistochemical staining. The results demonstrated that, 3 weeks after portal vein ligation, the vein area and the free portal pressures in the PHTC group were significantly increased compared with those in the NC group. The serum ALT and AST levels in the R group at different time points were significantly elevated compared with those in the PHTC group, and reached their maximal levels at 24 h after reperfusion. Furthermore, the PaO 2 at 24 h after reperfusion was significantly decreased. In conclusion, the reversible model of pre-hepatic portal hypertension in rats was successfully established using the introduction of a label ring. This model may be useful for basic research focusing on the anhepatic phase of orthotopic liver transplantation without veno-venous bypass.

  3. Evaluation of portal hypertension by MR portography

    International Nuclear Information System (INIS)

    Nagaoka, Shirou; Hagiwara, Masaru; Imanisi, Yosimasa

    1997-01-01

    Seventy-eight examinations of MR portography were totally performed in 24 controls and 33 patients with esophageal varices. Portal vein, SMV, hepatic vein, and IVC were entirely depicted in 21, 24, 22, and 24, respectively, of the 24 controls. As to intrahepatic upward branches of portal vein in the right lobe of the liver, the 4th branch was at least depicted in all of the 24. Although the portal vein trunk and SMV were entirely depicted in all of the 8 patients without treatment and liver dysfunction of Child A, there was no depiction of them in 1 of the 8 patients with liver dysfunction of Child B, and 1 of 5 patients with liver dysfunction of Child C. The 4th upward branch of portal vein in the right lobe of the liver was depicted in none of the 33 patients. Besides, none of the intrahepatic portal branches were depicted in 1 of 8 patients without treatment and liver dysfunction of Child B, and 1 of the 5 patients without treatment and liver dysfunction of Child C. There was a significant difference of depicted terminal upward branch of portal vein between the controls and patients without any treatment. In the patients without any significant difference of depicted terminal upward branch of portal vein was also present between Child's classification A and Child's classification B and C. Gastric coronary vein varices were detected by MR portography is 18 of 19 patients without treatment on the esophageal varices, and paraesophageal/esophageal varices were also depicted by MR portography in 13 of the 19. The collaterals were depicted by MR portography in all of the 6 patients with recurrent collaterals after Hassab's operation or splenectomy. MR portography was able to depict flow in trunk branches and collaterals of the portal vein system in a physiological state. (K.H.)

  4. Evaluation of portal hypertension by MR portography

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Shirou; Hagiwara, Masaru; Imanisi, Yosimasa [St. Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1997-02-01

    Seventy-eight examinations of MR portography were totally performed in 24 controls and 33 patients with esophageal varices. Portal vein, SMV, hepatic vein, and IVC were entirely depicted in 21, 24, 22, and 24, respectively, of the 24 controls. As to intrahepatic upward branches of portal vein in the right lobe of the liver, the 4th branch was at least depicted in all of the 24. Although the portal vein trunk and SMV were entirely depicted in all of the 8 patients without treatment and liver dysfunction of Child A, there was no depiction of them in 1 of the 8 patients with liver dysfunction of Child B, and 1 of 5 patients with liver dysfunction of Child C. The 4th upward branch of portal vein in the right lobe of the liver was depicted in none of the 33 patients. Besides, none of the intrahepatic portal branches were depicted in 1 of 8 patients without treatment and liver dysfunction of Child B, and 1 of the 5 patients without treatment and liver dysfunction of Child C. There was a significant difference of depicted terminal upward branch of portal vein between the controls and patients without any treatment. In the patients without any significant difference of depicted terminal upward branch of portal vein was also present between Child`s classification A and Child`s classification B and C. Gastric coronary vein varices were detected by MR portography is 18 of 19 patients without treatment on the esophageal varices, and paraesophageal/esophageal varices were also depicted by MR portography in 13 of the 19. The collaterals were depicted by MR portography in all of the 6 patients with recurrent collaterals after Hassab`s operation or splenectomy. MR portography was able to depict flow in trunk branches and collaterals of the portal vein system in a physiological state. (K.H.)

  5. Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification

    International Nuclear Information System (INIS)

    Looe, H.K.; Uphoff, Y.; Poppe, B.; Carl von Ossietzky Univ., Oldenburg; Harder, D.; Willborn, K.C.

    2012-01-01

    The quality of megavoltage clinical portal images is impaired by physical and geometrical effects. This image blurring can be corrected by a fast numerical two-dimensional (2D) deconvolution algorithm implemented in the electronic portal image device. We present some clinical examples of deconvolved portal images and evaluate the clinical advantages achieved by the improved sharpness and contrast. The principle of numerical 2D image deconvolution and the enhancement of sharpness and contrast thereby achieved are shortly explained. The key concept is the convolution kernel K(x,y), the mathematical equivalent of the smearing or blurring of a picture, and the computer-based elimination of this influence. Enhancements of sharpness and contrast were observed in all clinical portal images investigated. The images of fine bone structures were restored. The identification of organ boundaries and anatomical landmarks was improved, thereby permitting a more accurate comparison with the x-ray simulator radiographs. The visibility of prostate gold markers is also shown to be enhanced by deconvolution. The blurring effects of clinical portal images were eliminated by a numerical deconvolution algorithm that leads to better image sharpness and contrast. The fast algorithm permits the image blurring correction to be performed in real time, so that patient positioning verification with increased accuracy can be achieved in clinical practice. (orig.)

  6. Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification

    Energy Technology Data Exchange (ETDEWEB)

    Looe, H.K.; Uphoff, Y.; Poppe, B. [Pius Hospital, Oldenburg (Germany). Clinic for Radiation Therapy; Carl von Ossietzky Univ., Oldenburg (Germany). WG Medical Radiation Physics; Harder, D. [Georg August Univ., Goettingen (Germany). Medical Physics and Biophysics; Willborn, K.C. [Pius Hospital, Oldenburg (Germany). Clinic for Radiation Therapy

    2012-02-15

    The quality of megavoltage clinical portal images is impaired by physical and geometrical effects. This image blurring can be corrected by a fast numerical two-dimensional (2D) deconvolution algorithm implemented in the electronic portal image device. We present some clinical examples of deconvolved portal images and evaluate the clinical advantages achieved by the improved sharpness and contrast. The principle of numerical 2D image deconvolution and the enhancement of sharpness and contrast thereby achieved are shortly explained. The key concept is the convolution kernel K(x,y), the mathematical equivalent of the smearing or blurring of a picture, and the computer-based elimination of this influence. Enhancements of sharpness and contrast were observed in all clinical portal images investigated. The images of fine bone structures were restored. The identification of organ boundaries and anatomical landmarks was improved, thereby permitting a more accurate comparison with the x-ray simulator radiographs. The visibility of prostate gold markers is also shown to be enhanced by deconvolution. The blurring effects of clinical portal images were eliminated by a numerical deconvolution algorithm that leads to better image sharpness and contrast. The fast algorithm permits the image blurring correction to be performed in real time, so that patient positioning verification with increased accuracy can be achieved in clinical practice. (orig.)

  7. Inpatient Portals for Hospitalized Patients and Caregivers: A Systematic Review.

    Science.gov (United States)

    Kelly, Michelle M; Coller, Ryan J; Hoonakker, Peter Lt

    2018-06-01

    Patient portals, web-based personal health records linked to electronic health records (EHRs), provide patients access to their healthcare information and facilitate communication with providers. Growing evidence supports portal use in ambulatory settings; however, only recently have portals been used with hospitalized patients. Our objective was to review the literature evaluating the design, use, and impact of inpatient portals, which are patient portals designed to give hospitalized patients and caregivers inpatient EHR clinical information for the purpose of engaging them in hospital care. Literature was reviewed from 2006 to 2017 in PubMed, Web of Science, CINALPlus, Cochrane, and Scopus to identify English language studies evaluating patient portals, engagement, and inpatient care. Data were analyzed considering the following 3 themes: inpatient portal design, use and usability, and impact. Of 731 studies, 17 were included, 9 of which were published after 2015. Most studies were qualitative with small samples focusing on inpatient portal design; 1 nonrandomized trial was identified. Studies described hospitalized patients' and caregivers' information needs and design recommendations. Most patient and caregiver participants in included studies were interested in using an inpatient portal, used it when offered, and found it easy to use and/or useful. Evidence supporting the role of inpatient portals in improving patient and caregiver engagement, knowledge, communication, and care quality and safety is limited. Included studies indicated providers had concerns about using inpatient portals; however, the extent to which these concerns have been realized remains unclear. Inpatient portal research is emerging. Further investigation is needed to optimally design inpatient portals to maximize potential benefits for hospitalized patients and caregivers while minimizing unintended consequences for healthcare teams. © 2017 Society of Hospital Medicine.

  8. Celiac disease as a potential cause of idiopathic portal hypertension: a case report

    Directory of Open Access Journals (Sweden)

    Zamani Farhad

    2009-02-01

    Full Text Available Abstract Introduction Idiopathic portal hypertension is a disorder of unknown etiology, clinically characterized by portal hypertension, splenomegaly and anemia secondary to hypersplenism. Case presentation A 54-year-old man was admitted to our hospital for evaluation of malaise, weight loss, abdominal swelling and lower limb edema. His paraclinical tests revealed pancytopenia, large ascites, splenomegaly and esophageal varices consistent with portal hypertension. Duodenal biopsy and serologic findings were compatible with celiac disease. His symptoms improved on a gluten-free diet, but his clinical course was further complicated with ulcerative jejunoileitis, and intestinal T-cell lymphoma. Conclusion It seems that celiac disease, by an increased immune reaction in the splenoportal axis, can result in the development of idiopathic portal hypertension in susceptible affected patients.

  9. [Evaluation and treatment of portal hypertension].

    Science.gov (United States)

    Brůha, Radan; Petrtýl, Jaromír

    Liver cirrhosis is a serious disease shortening the life expectancy. Unavoidable consequence of cirrhosis is portal hypertension, which usually limits the prognosis by its complications. Portal hypertension is a prognostic factor for cirrhosis decompensation, variceal bleeding and even the mortality in cirrhotic patients. In the evaluation of portal hypertension hepatic venous pressure gradient (HVPG) measurement is used.Measurement of HVPG is used in clinical praxis in these situations: diagnosis of portal hypertension, evaluation of prognosis of patients with cirrhosis, monitoring the treatment efficacy in the prevention of variceal bleeding, management of acute variceal bleeding. Decrease of HVPG below 12 mmHg or at least for more than 20% of initial value in the treatment by beta-blockers is associated with the lower risk of bleeding from varices or other complications. HVPG above 20 mm Hg is associated with the high risk of early rebleeding from varices and can discriminate those patients profiting from early TIPS.HVPG measurement is an invasive, but simple, reproducible and safe catheterization technique with minimal complication rate. The most frequent complication could be incorrect assessment of obtained values. HVPG measurement should be a routine technique in centers specialized to liver diseases.

  10. Reliability in endoscopic diagnosis of portal hypertensive gastropathy

    Science.gov (United States)

    de Macedo, George Fred Soares; Ferreira, Fabio Gonçalves; Ribeiro, Maurício Alves; Szutan, Luiz Arnaldo; Assef, Mauricio Saab; Rossini, Lucio Giovanni Battista

    2013-01-01

    AIM: To analyze reliability among endoscopists in diagnosing portal hypertensive gastropathy (PHG) and to determine which criteria from the most utilized classifications are the most suitable. METHODS: From January to July 2009, in an academic quaternary referral center at Santa Casa of São Paulo Endoscopy Service, Brazil, we performed this single-center prospective study. In this period, we included 100 patients, including 50 sequential patients who had portal hypertension of various etiologies; who were previously diagnosed based on clinical, laboratory and imaging exams; and who presented with esophageal varices. In addition, our study included 50 sequential patients who had dyspeptic symptoms and were referred for upper digestive endoscopy without portal hypertension. All subjects underwent upper digestive endoscopy, and the images of the exam were digitally recorded. Five endoscopists with more than 15 years of experience answered an electronic questionnaire, which included endoscopic criteria from the 3 most commonly used Portal Hypertensive Gastropathy classifications (McCormack, NIEC and Baveno) and the presence of elevated or flat antral erosive gastritis. All five endoscopists were blinded to the patients’ clinical information, and all images of varices were deliberately excluded for the analysis. RESULTS: The three most common etiologies of portal hypertension were schistosomiasis (36%), alcoholic cirrhosis (20%) and viral cirrhosis (14%). Of the 50 patients with portal hypertension, 84% were Child A, 12% were Child B, 4% were Child C, 64% exhibited previous variceal bleeding and 66% were previously endoscopic treated. The endoscopic parameters, presence or absence of mosaic-like pattern, red point lesions and cherry-red spots were associated with high inter-observer reliability and high specificity for diagnosing Portal Hypertensive Gastropathy. Sensitivity, specificity and reliability for the diagnosis of PHG (%) were as follows: mosaic-like pattern

  11. Indocyanine green retention test (ICG-r15) as a noninvasive predictor of portal hypertension in patients with different severity of cirrhosis

    DEFF Research Database (Denmark)

    Pind, Marie-Louise Lindberg; Bendtsen, Flemming; Kallemose, Thomas

    2016-01-01

    BACKGROUND AND AIMS: Portal hypertension is a severe consequence of chronic liver disease, responsible for the main clinical complications of cirrhosis. Measurement of the hepatic venous pressure gradient (HVPG) provides important clinical information, but the procedure is invasive and demands...... as a noninvasive predictor of portal hypertension. METHODS: A total of 325 patients were studied. During a hemodynamic investigation, the ICG clearance was determined using the constant infusion technique and ICG-r15 was calculated. RESULTS: Assessment of the diagnostic performance of ICG clearance and ICG-r15...... significant results in Child class B (AUROC=0.7448) and Child class C patients (AUROC=0.7392). Only six out of 102 patients in Child class C had HVPG of less than 12 mmHg. CONCLUSION: ICG-r15 can be used as an indirect assessment of significant portal hypertension in compensated cirrhotic patients. ICG-r15...

  12. Total hepatofugal portal blood flow in cirrhosis demonstrated by transhepatic portography

    International Nuclear Information System (INIS)

    Burcharth, F.; Aagaard, J.; Herlev Hospital

    1988-01-01

    We investigated 108 patients with cirrhosis of the liver and portal hypertension by percutaneous transhepatic portography to demonstrate the occurrence and frequency of total hepatofugal portal blood flow. Sixteen patients (14.8%) had a total hepatofugal portal blood flow. The aetiology of portal hypertension and the portal pressure did not differ from that in the group of patients with hepatopetal portal blood flow. A significantly higher percentage of patients in the group with hepatofugal flow had gastro-oesophageal varices (P [de

  13. Radionuclide splenoportography in patients with portal hypertension

    International Nuclear Information System (INIS)

    Kuriya, Kouji; Nagamachi, Shigeki; Hoshi, Hiroaki; Ohnishi, Takashi; Jinnouchi, Masashi; Futami, Sigemi; Yoshida, Akira; Watanabe, Katsuji

    1991-01-01

    Splenoportography using 99m Tc-pertechnetate was performed in 18 patients with portal hypertension. 99m Tc pertechnetate (370 MBq) was directly injected into the spleen. Co-lateral circulation of portal vein was observed in 13 of 18 patients (72%). L/H ratio was also calculated by the time activity curve of dynamic images. L/H ratio was significantly lower (p<0.05) in patients with colateral vessels and severe esophageal varix. Radionuclide splenography was an useful method for evaluating hemodynamics of portal vein. (author)

  14. Portal hypertension: Imaging of portosystemic collateral pathways and associated image-guided therapy.

    Science.gov (United States)

    Bandali, Murad Feroz; Mirakhur, Anirudh; Lee, Edward Wolfgang; Ferris, Mollie Clarke; Sadler, David James; Gray, Robin Ritchie; Wong, Jason Kam

    2017-03-14

    Portal hypertension is a common clinical syndrome, defined by a pathologic increase in the portal venous pressure. Increased resistance to portal blood flow, the primary factor in the pathophysiology of portal hypertension, is in part due to morphological changes occurring in chronic liver diseases. This results in rerouting of blood flow away from the liver through collateral pathways to low-pressure systemic veins. Through a variety of computed tomographic, sonographic, magnetic resonance imaging and angiographic examples, this article discusses the appearances and prevalence of both common and less common portosystemic collateral channels in the thorax and abdomen. A brief overview of established interventional radiologic techniques for treatment of portal hypertension will also be provided. Awareness of the various imaging manifestations of portal hypertension can be helpful for assessing overall prognosis and planning proper management.

  15. Radiological score for hemorrhage in the patients with portal hypertension.

    Science.gov (United States)

    Ge, Wei; Wang, Yi; Cao, Ya-Juan; Xie, Min; Ding, Yi-Tao; Zhang, Ming; Yu, De-Cai

    2015-01-01

    To analyze the risk factors from radiological indices for hemorrhage in the patients with portal hypertension and weight risk factors. We retrospectively analyzed all cases of portal hypertension with hepatitis B from June 2008 to June 2014 in Nanjing Drum Tower hospital. Patients with hepatocellular carcinoma, portal vein thrombosis, or portal hypertension with other causes, such as autoimmune hepatitis, pancreatitis, or hematological diseases were excluded. Ninety-eight patients were recruited and divided into hemorrhage and non-hemorrhage groups. There were no statistical differences in clinical indexes such as age, prothrombin time, serum albumin, serum creatinine, serum sodium, hemameba, and blood platelet count. However, the differences were statistically significant in total bilirubin, hemoglobin, and liver function with the p values of 0.023, 0.000, and 0.039 respectively. For radiological indices, hemorrhage was correlated with diameter of inferior mesenteric vein (P=0.0528), posterior gastric vein (P=0.0283), and esophageal varices scores (P=0.0221). Logistic procedure was used to construct the model with stepwise selection and finally inferior mesenteric vein, posterior gastric vein, esophageal varices, and short gastric vein were enrolled into the model. These veins were scored according to the diameters and the rates of hemorrhage were increased with the score. We then validated the model with 26 patents from July 2014 to December 2014. The AUC value was 0.8849 in ROC curves for this radiological model. A risk model was constructed including inferior mesenteric vein, esophageal varices, posterior gastric vein, and short gastric vein. This radiological scoring model may be a valuable indicator for hemorrhage of portal hypertension.

  16. Racial/ethnic variation in devices used to access patient portals.

    Science.gov (United States)

    Chang, Eva; Blondon, Katherine; Lyles, Courtney R; Jordan, Luesa; Ralston, James D

    2018-01-01

    We examined racial/ethnic variation in the devices used by patients to access medical records through an online patient portal. Retrospective, cross-sectional analysis. Using data from 318,700 adults enrolled in an integrated delivery system between December 2012 and November 2013, we examined: 1) online patient portal use that directly engages the electronic health record and 2) portal use over desktops/laptops only, mobile devices only, or both device types. The primary covariate was race/ethnicity (non-Hispanic white, black, Hispanic, and Asian). Other covariates included age, sex, primary language, and neighborhood-level income and education. Portal use and devices used were assessed with multiple and multinomial logistic models, respectively. From December 2012 to November 2013, 56% of enrollees used the patient portal. Of these portal users, 62% used desktops/laptops only, 6% used mobile devices only, and 32% used both desktops/laptops and mobile devices. Black, Hispanic, and Asian enrollees had significantly lower odds of portal use than whites. Black and Hispanic portal users also were significantly more likely to use mobile devices only (relative risk ratio, 1.73 and 1.44, respectively) and both device types (1.21 and 1.07, respectively) than desktops/laptops only compared with whites. Although racial/ethnic minority enrollees were less likely to access the online patient portal overall, a greater proportion of black and Hispanic users accessed the patient portal with mobile devices than did non-Hispanic white users. The rapid spread of mobile devices among racial/ethnic minorities may help reduce variation in online patient portal use. Mobile device use may represent an opportunity for healthcare organizations to further engage black and Hispanic enrollees in online patient portal use.

  17. Protection of estrogen in portal hypertension gastropathy: an experimental model

    Directory of Open Access Journals (Sweden)

    Maria Isabel Morgan-Martins

    2011-09-01

    Full Text Available CONTEXT: Portal hypertension is a complication secondary to cirrhosis that is characterized by increased blood flow and/or vascular resistance in the portal system, causing the appearance of a hyperdynamic collateral circulation. Partial portal vein ligation is an experimental model used in rats to study the pathophysiological mechanisms involved in pre-hepatic portal hypertension. Estrogen E2 is an antioxidant molecule with various physiological actions. OBJECTIVES: To evaluate the antioxidant activity of endogenous estrogen in an experimental model of partial portal vein ligation by comparing intact with castrated rats. METHODS: Twenty Wistar rats, weighing on average 250 g were used and divided into four groups: sham-operated (SO; intact (I with partial portal vein ligation (I + PPVL, castrated (C and castrated with partial ligation of the vein (C + PPVL. Day 1: castration or sham-operation; day 7, PPVL surgery; on day 15 post-PPVL, portal pressure in the mesenteric vein of rats was measured on polygraph Letica. Lipid peroxidation in the stomach was assessed using the technique of thiobarbituric acid reactive substances and activity of antioxidant enzymes superoxide dismutase, catalase and glutathione peroxidase. Statistical analysis was done with ANOVA - Student-Newman-Keuls (mean ± SE, and P<0.05 was considered as significant. RESULTS: Portal pressure was significantly increased in C + PPVL as compared to the other groups. There was no significant difference in the group of intact rats. TBARS showed significant damage in C and C + PPVL in relation to others. Antioxidant enzymes were significantly increased in the castrated rats with subsequent PPVL as compared to the other groups. CONCLUSION: We suggest that estrogen E2 plays a protective role in intact compared with castrated rats because it presents hydrophenolic radicals in its molecule, thus acting as an antioxidant in this experimental model.

  18. Protection of estrogen in portal hypertension gastropathy: an experimental model.

    Science.gov (United States)

    Morgan-Martins, Maria Isabel; Jacques, Simone Iahnig; Hartmann, Renata Minuzzo; Marques, Camila Moraes; Marroni, Cláudio Augusto; Marroni, Norma Possa

    2011-01-01

    Portal hypertension is a complication secondary to cirrhosis that is characterized by increased blood flow and/or vascular resistance in the portal system, causing the appearance of a hyperdynamic collateral circulation. Partial portal vein ligation is an experimental model used in rats to study the pathophysiological mechanisms involved in pre-hepatic portal hypertension. Estrogen E2 is an antioxidant molecule with various physiological actions. To evaluate the antioxidant activity of endogenous estrogen in an experimental model of partial portal vein ligation by comparing intact with castrated rats. Twenty Wistar rats, weighing on average 250 g were used and divided into four groups: sham-operated (SO); intact (I) with partial portal vein ligation (I + PPVL), castrated (C) and castrated with partial ligation of the vein (C + PPVL). Day 1: castration or sham-operation; day 7, PPVL surgery; on day 15 post-PPVL, portal pressure in the mesenteric vein of rats was measured on polygraph Letica. Lipid peroxidation in the stomach was assessed using the technique of thiobarbituric acid reactive substances and activity of antioxidant enzymes superoxide dismutase, catalase and glutathione peroxidase. Statistical analysis was done with ANOVA - Student-Newman-Keuls (mean ± SE), and P<0.05 was considered as significant. Portal pressure was significantly increased in C + PPVL as compared to the other groups. There was no significant difference in the group of intact rats. TBARS showed significant damage in C and C + PPVL in relation to others. Antioxidant enzymes were significantly increased in the castrated rats with subsequent PPVL as compared to the other groups. We suggest that estrogen E2 plays a protective role in intact compared with castrated rats because it presents hydrophenolic radicals in its molecule, thus acting as an antioxidant in this experimental model.

  19. Pulmonary hypertension in patients with hepatic cirrhosis and portal hypertension. An echographic study.

    Science.gov (United States)

    Gurghean, Adriana V; Tudor, Ioana A

    2017-01-01

    The aim of the study is to determine the frequency of pulmonary hypertension in patients with hepatic cirrhosis and portal hypertension, to determine the possibility of an accurate ultrasound diagnosis of the characteristics of this complication. 347 patients with liver cirrhosis consecutively hospitalized at Coltea Clinical Hospital were screened. 61 were excluded because of other possible causes of portal or pulmonary hypertension. All patients were investigated clinically and by abdominal and cardiac ultrasonography. Of the remaining 286 patients, 116 had portal hypertension, 27 of them (23%) having pulmonary hypertension. In this group we found a higher cardiac index and right atrial volume, higher pressures in the right atrium, suggesting a hyperdynamic state. Porto-pulmonary hypertension was found in only one patient. Echocardiography permits characterization of patients with cirrhosis and portal hypertension.

  20. Autoradiographic study of the regional distribution of gastric blood flow in portal hypertensive rats

    International Nuclear Information System (INIS)

    Geraghty, J.G.; Angerson, W.J.; Carter, D.C.

    1989-01-01

    This study measures regional gastric blood flow in portal hypertensive rats at three separate periods after portal vein ligation using quantitative autoradiography with 14C-labeled iodoantipyrine. The level of corpus mucosal blood flow was significantly reduced in 3-day portal vein-ligated animals compared with sham-operated control animals (30.4 +/- 2.3 vs. 47.1 +/- 5.6 ml/100 g.min). There was no significant difference in corpus mucosal blood flow between portal vein-ligated and sham-operated animals at 7- and 28-day periods, although the level of perfusion was higher in the 28-day portal vein-ligated group. There was no significant difference in antral mucosal or muscle blood flow between portal hypertensive and control animals at any of the study periods. We conclude that the acute period after portal vein ligation is associated with a reduced corpus mucosal microcirculation but that this effect is not sustained in portal hypertensive animals studied at later intervals after portal vein ligation

  1. Trial on MR portal blood flow measurement with phase contrast technique

    International Nuclear Information System (INIS)

    Tsunoda, Masatoshi; Kimoto, Shin; Togami, Izumi

    1991-01-01

    Portal blood flow measurement is considered to be important for the analysis of hemodynamics in various liver diseases. The Doppler ultrasound method has been used extensively during the past several years for measuring portal blood flow, as a non-invasive method. However, the Doppler ultrasound technique do not allow the portal blood flow to be measured in cases of obesity, with much intestinal gas, and so on. In this study, we attempted to measure the blood flow in the main trunk of portal vein as an application of MR phase contrast technique to the abdominal region. In the flow phantom study, the flow volumes and the velocities measured by phase contrast technique showed a close correlation with those measured by electromagnetic flowmeter. In the clinical study with 10 healthy volunteers, various values of portal blood flow were obtained. Mean portal blood flow could be measured within the measuring time (about 8 minutes) under natural breathing conditions. Phase contrast technique is considered to be useful for the non-invasive measurement of portal blood flow. (author)

  2. Advances in diagnosis and treatment of portal hypertensive biliopathy

    Directory of Open Access Journals (Sweden)

    WENG Ningna

    2014-08-01

    Full Text Available With the progress in research on portal hypertension in recent years, portal hypertensive biliopathy (PHB has attracted more and more attention. The pathophysiology and clinical manifestations of PHB, as well as the main methods for the diagnosis and treatment of this disease, are briefly described. The pathogenesis of PHB remains unclear, and it has been postulated that the external pressure of portal cavernoma and the ischemic stricture of the bile duct may play a role. Magnetic resonance cholangiopancreatography is the primary diagnostic tool for PHB. Currently, it is thought that asymptomatic PHB patients do not require any treatment, and symptomatic PHB patients should receive individualized treatment, which mainly included reducing portal pressure and relieving biliary obstruction. Transjugular intrahepatic portosystemic shunt has become the first-line therapy for symptomatic PHB. More research and practice are needed for further understanding of PHB.

  3. The clinical choice in the method of interventional treatment to portal hypertension

    International Nuclear Information System (INIS)

    Shen Qi; Jiang Zhongpu; Ren Lijun

    2004-01-01

    Objective: To explore the selection of reasonable interventional treatment to portal hypertension under different conditions. Methods: The data of 76 patients with portal hypertension and interventional treatment from 1997 to 2002 were retrospectively analyzed. 26 patients were treated with transjugular intrahepatic porto-systemic stent shunt (TIPSS). Of these 26 patients, 11 patients suffered from hemorrhage after surgery treatment by devascularization, 6 patients with hemorrhage after stomach mirror treatment, and 9 patients with ineffective medicine treatment. 50 patients were treated with percutaneous transhepatic variceal embolization (PTVE) combined with partial splenic embolization (PSE), and they all showed inefficacy by medicine treatment. Free portal pressure ( FPP) in pre- and post-treatment was measured in all 76 cases. The hepatic volume was measured by spiral-CT before and one year after the treatment. Results: In TIPSS group, FPP was reduced from (3.85 ± 0.42) kPa to (3.09 ± 0.44) kPa (t=3.682, P 3 was obviously higher than those with volume more than 700 cm 3 after TIPSS (χ 2 =4.37, P<0.05). Hypersplenism was completely resolved in both groups. Conclusion: The two kinds interventional treatments for portal hypertension each have their own advantages and disadvantages. The selection of interventional treatment should be based on the actual needs of the patients. The hepatic volume is a diathesis of importance in the evaluation and selection of treatment methods. (authors)

  4. A Climate Information Portal for Copernicus: a central portal for European climate services?

    Science.gov (United States)

    Juckes, Martin; Swart, Rob; Thysse, Peter; Som de Cerff, Wim; Groot, Annemarie; Bennett, Victoria; Costa, Luis; Lückenkötter, Johannes; Callaghan, Sarah

    2015-04-01

    The FP7 project "Climate Information Portal for Copernicus" (CLIPC) is developing a demonstration portal for the Copernicus Climate Change Service (C3S). This project is one of a suite of FP7 research activities which are administratively independent of Copernicus, focussed on creating the technical and scientific building blocks needed for the service. It is to be expected that at EGU 2015 there will be many presentations describing portals delivering new and innovative ranges of services. It would be unwise to seek to replace all this creative activity with a single portal -- instead CLIPC is designing a portal to make distributed resources more accessible through flexible discovery systems. CLIPC needs to deliver more than a directory of resources: resources need to be presented in common protocols so that users can access multiple datasets. More information about the project objectives is available at www.clipc.eu. The gulf between the climate science communities and the end user communities is a central challenge being addressed in the project. It is important to understand that there is significant diversity and multiple communication barriers within these two sets of communities as well as between them. The CLIPC services must presentation will provide a review of progress towards this ambitious goal, through a discussion of user requirements activities, an overview of the proposed architecture, work on assessing and adjusting model biasses, and a discussion of the climate impact indicators which will be provided through the portal. When looking at the usability of data for the various users, CLIPC will implement a set of services functioning as a "knowledge base" supplying information to users about the data, including definitions of terminology used, quality of datasets, versioning, and user annotations.

  5. Pro-C5, a marker of true type V collagen formation and fibrillation, correlates with portal hypertension in patients with alcoholic cirrhosis

    DEFF Research Database (Denmark)

    Leeming, Diana J; Veidal, Sanne S; Karsdal, Morten A

    2015-01-01

    Pro-C5 reflects liver hemodynamics, liver function, disease stage and clinically significant portal hypertension (PH). A multimarker model in combination with clinical scores predicted HVPG and separated clinical relevant HVPG thresholds. Plasma Pro-C5 may be suitable for the noninvasive evaluation...

  6. The feasible study of vasodilators in portal vein targeting infusion for treating portal hypertension

    International Nuclear Information System (INIS)

    Wu Hanping; Liang Huiming; Zheng Chuansheng; Feng Gansheng

    2002-01-01

    Objective: To find out the ideal portal vein tar getting injection routes for portal hypertension treatment. Methods: 28 cirrhotic rat models with portal hypertension induced by CCl 4 were divided into 4 groups: inferior caval vein injection group, portal vein injection group, hepatic artery injection group, spleen injection group. The changes in portal vein pressure (PVP), inferior caval vein pressure (ICVP), mean artery pressure (MAP) and heart rate (HR) were monitored before and after prazosin injection. Results: After intra-portal, intra-hepatic arterial or spleen injection of prazosin, larger decrease in PVP and lesser effects on MAP than intravenous injection had been induced. The effect on HR showed no difference among these four groups. Conclusions: Hepatic artery and spleen prazosin administration have the same advantages on treatment of portal hypertension as those of intra-portal infusion, that is the greater decrease on portal vein pressure, the lesser effects on systemic hemodynamics. Vasodilation drugs for hepatic artery infusion through percutaneous port catheter system by hepatic artery implantation would be an ideal method for portal hypertension treatment

  7. [Treatment of non-cirrhotic, non-tumoural portal vein thrombosis].

    Science.gov (United States)

    Llop, Elba; Seijo, Susana

    2016-01-01

    Thrombosis of the splenoportal axis not associated with liver cirrhosis or neoplasms is a rare disease whose prevalence ranges from 0.7 to 3.7 per 100,000 inhabitants. However, this entity is the second most common cause of portal hypertension. Prothrombotic factors are present as an underlying cause in up to 70% of patients and local factors in 10-50%. The coexistence of several etiological factors is frequent. Clinical presentation may be acute or chronic (portal cavernomatosis). The acute phase can present as abdominal pain, nausea, vomiting, fever, rectorrhagia, intestinal congestion, and ischemia. In this phase, early initiation of anticoagulation is essential to achieve portal vein recanalization and thus improve patient prognosis. In the chronic phase, symptoms are due to portal hypertension syndrome. In this phase, the aim of treatment is to treat or prevent the complications of portal hypertension. Anticoagulation is reserved to patients with a proven underlying thrombophilic factor. Copyright © 2016 Elsevier España, S.L.U. y AEEH y AEG. All rights reserved.

  8. Portal vein thrombosis.

    Science.gov (United States)

    Chawla, Yogesh K; Bodh, Vijay

    2015-03-01

    Portal vein thrombosis is an important cause of portal hypertension. PVT occurs in association with cirrhosis or as a result of malignant invasion by hepatocellular carcinoma or even in the absence of associated liver disease. With the current research into its genesis, majority now have an underlying prothrombotic state detectable. Endothelial activation and stagnant portal blood flow also contribute to formation of the thrombus. Acute non-cirrhotic PVT, chronic PVT (EHPVO), and portal vein thrombosis in cirrhosis are the three main variants of portal vein thrombosis with varying etiological factors and variability in presentation and management. Procoagulant state should be actively investigated. Anticoagulation is the mainstay of therapy for acute non-cirrhotic PVT, with supporting evidence for its use in cirrhotic population as well. Chronic PVT (EHPVO) on the other hand requires the management of portal hypertension as such and with role for anticoagulation in the setting of underlying prothrombotic state, however data is awaited in those with no underlying prothrombotic states. TIPS and liver transplant may be feasible even in the setting of PVT however proper selection of candidates and type of surgery is warranted. Thrombolysis and thrombectomy have some role. TARE is a new modality for management of HCC with portal vein invasion.

  9. Diagnostic accuracy of point shear wave elastography in the detection of portal hypertension in pediatric patients.

    Science.gov (United States)

    Burak Özkan, M; Bilgici, M C; Eren, E; Caltepe, G

    2018-03-01

    The purpose of this study was to determine the usefulness of point shear wave elastography (p-SWE) of the liver and spleen for the detection of portal hypertension in pediatric patients. The study consisted of 38 healthy children and 56 pediatric patients with biopsy-proven liver disease who underwent splenic and liver p-SWE. The diagnostic performance of p-SWE in detecting clinically significant portal hypertension was assessed using receiver operating characteristic (ROC) curves. Reliable measurements of splenic and liver stiffness with p-SWE were obtained in 76/94 (81%) and 80/94 patients (85%), respectively. The splenic stiffness was highest in the portal hypertension group (Pportal hypertension was lower for splenic p-SWE than for liver p-SWE (0.906 vs. 0.746; P=0.0239). The cut-off value of splenic p-SWE for portal hypertension was 3.14m/s, with a specificity of 98.59% and a sensitivity of 68.18%. The cut-off value of liver p-SWE for portal hypertension was 2.09m/s, with a specificity of 80.28% and a sensitivity of 77.27%. In pediatric patients, p-SWE is a reliable method for detecting portal hypertension. However, splenic p-SWE is less accurate than liver p-SWE for the diagnosis of portal hypertension. Copyright © 2017 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  10. Low density in liver of idiopathic portal hypertension. A computed tomographic observation with possible diagnostic significance

    Energy Technology Data Exchange (ETDEWEB)

    Ishito, Hiroyuki

    1988-01-01

    In order to evaluate the diagnostic value of low density in liver on computed tomography (CT), CT scans of 11 patients with idiopathic portal hypertension (IPH) were compared with those from 22 cirrhotic patients, two patients with scarred liver and 16 normal subjects. Low densities on plain CT scans in patients with IPH were distinctly different from those observed in normal liver. Some of the low densities had irregular shape with unclear margin and were scattered near the liver surface, and others had vessel-like structures with unclear margin and extended as far as near the liver surface. Ten of the 11 patients with IPH had low densities mentioned above, while none of the 22 cirrhotic patients had such low densities. The present results suggest that the presence of low densities in liver on plain CT scan is clinically beneficial in diagnosis of IPH.

  11. Macronodular hepatic tuberculosis associated with portal vein thrombosis and portal hypertension

    International Nuclear Information System (INIS)

    Venkatesh, S.K.; Tan, L.K.A.; Siew, E.P.Y.; Putti, T.C.

    2005-01-01

    Tuberculosis (TB) of the liver is usually associated with miliary spread. Macronodular TB of the liver is rare. A case of macronodular TB of the liver in a 31-year-old woman causing portal vein thrombosis and portal hypertension is presented. Ultrasound and CT appearances are described. There was coexistent ileo-caecal TB with extensive mesenteric and retroperitoneal lymphadenopathy. Macronodular TB should be considered in the differential diagnosis when a patient presents with multiple calcified masses in the liver with portal vein thrombosis and portal hypertension. Copyright (2005) Blackwell Science Pty Ltd

  12. Noncirrotisk intrahepatisk portal hypertension

    DEFF Research Database (Denmark)

    Dam Fialla, Annette; Havelund, Troels

    2007-01-01

    Non-cirrhotic intrahepatic portal hypertension is characterized by portal hypertension in the absence of liver cirrhosis or portal vein thrombosis. The disease is common in the East and rarely seen in the West. Two cases with oesophageal varices are described. The histopathology is heterogeneous...... but includes vascular lesions and portal fibrosis. Patient management follows the current recommendations for variceal bleeding....

  13. Hepatic angiography: Portal hypertension

    International Nuclear Information System (INIS)

    Oliver, T.W. Jr.; Sones, P.J. Jr.

    1985-01-01

    Portal hypertension is usually a manifestation of underlying hepatic parenchymal disease, although it may be secondary to portal or hepatic venous thrombosis and rarely to hyperdynamic portal states. Portal hypertension may present as encephalopathy, ascites, jaundice, hepatic failure, or catastrophic upper gastrointestinal hemorrhage. Radiologic investigation should include indirect or direct measurements of portal pressure, assessment of portal venous perfusion, visualization of collaterals, and demonstration of arterial and venous anatomy for potential shunt procedure. Following survival of initial variceal bleeding, the most effective procedure to prevent recurrent hemorrhage is a shunt to decompress the varices. The decision whether to intervene medically or surgically during the acute hemorrhagic episode as well as the type of shunt used to prevent future hemorrhage is the subject of continuing controversy

  14. The portal hypertension syndrome: etiology, classification, relevance, and animal models.

    Science.gov (United States)

    Bosch, Jaime; Iwakiri, Yasuko

    2018-02-01

    Portal hypertension is a key complication of portal hypertension, which is responsible for the development of varices, ascites, bleeding, and hepatic encephalopathy, which, in turn, cause a high mortality and requirement for liver transplantation. This review deals with the present day state-of-the-art preventative treatments of portal hypertension in cirrhosis according to disease stage. Two main disease stages are considered, compensated and decompensated cirrhosis, the first having good prognosis and being mostly asymptomatic, and the second being heralded by the appearance of bleeding or non-bleeding complications of portal hypertension. The aim of treatment in compensated cirrhosis is preventing clinical decompensation, the more frequent event being ascites, followed by variceal bleeding and hepatic encephalopathy. Complications are mainly driven by an increase of hepatic vein pressure gradient (HVPG) to values ≥10 mmHg (defining the presence of Clinically Significant Portal Hypertension, CSPH). Before CSPH, the treatment is limited to etiologic treatment of cirrhosis and healthy life style (abstain from alcohol, avoid/correct obesity…). When CSPH is present, association of a non-selective beta-blocker (NSBB), including carvedilol should be considered. NSBBs are mandatory if moderate/large varices are present. Patients should also enter a screening program for hepatocellular carcinoma. In decompensated patients, the goal is to prevent further bleeding if the only manifestation of decompensation was a bleeding episode, but to prevent liver transplantation and death in the common scenario where patients have manifested first non-bleeding complications. Treatment is based on the same principles (healthy life style..) associated with administration of NSBBs in combination if possible with endoscopic band ligation if there has been variceal bleeding, and complemented with simvastatin administration (20-40 mg per day in Child-Pugh A/B, 10-20 mg in Child C

  15. Portal hypertension and variceal bleeding: Clinical and pharmacological aspects

    DEFF Research Database (Denmark)

    Hobolth, Lise

    2010-01-01

    Blødende esophagus varicer er en af den mest frygtede komplikationer til cirrose og portal hypertension pga. den høje mortalitet. Et klassisk studie fra 1981 opgjorde 6-ugers mortaliteten til 42%, hvoraf 75% døde indenfor den første uge. Gennem de sidste 2-3 årtier er der introduceret en række nye...

  16. Treatment of chronic portal-systemic encephalopathy with lactose in lactase-deficient patients.

    Science.gov (United States)

    Uribe, M; Márquez, M A; García-Ramos, G; Escobedo, V; Murillo, H; Guevara, L; Lisker, R

    1980-12-01

    A controlled cross-over clinical comparison of lactose (50 g twice a day) versus neomycin (3 g/day) plus milk of magnesia, was carried out in ten cirrhotic patients with chronic portal-systemic encephalopathy and documented lactase deficiency. Serial semiquantitative assessments were done including: mental state, asterixis, number connection test, electroencephalogram, and blood ammonia levels. No patient developed deep coma while ingesting either lactose or neomycin plus milk of magnesia. However, a significant improvement of mental state, asterixis, number connection tests, and electroencephalograms was evident during lactose therapy. apart from mild diarrhea and bloating, no severe side effects were noticeable during lactose treatment. Based on these results, we propose lactose as a valuable alternate treatment of portal-systemic encephalopathy in lactase-deficient populations.

  17. Percutaneous angioplasty of portal vein stenosis that complicated liver transplantation: the mid-term therapeutic results

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kwang Bo; Choo, Sung Wook; Do, Young Soo; Shin, Sung Wook; Cho, Sung Gi; Choo, In Wook [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2005-09-15

    We wanted to valuate the mid-term therapeutic results of percutaneous transhepatic balloon angioplasty for portal vein stenosis after liver transplantation. From May 1996 to Feb 2005, 420 patients underwent liver transplantation. Percutaneous transhepatic angioplasty of the portal vein was attempted in six patients. The patients presented with the clinical signs and symptoms of portal venous hypertension or they were identified by surveillance doppler ultrasonography. The preangioplasty and postangioplasty pressure gradients were recorded. The therapeutic results were monitored by the follow up of the clinical symptoms, the laboratory values, CT and ultrasonography. The overall technical success rate was 100%. The clinical success rate was 83% (5/6). A total of eight sessions of balloon angioplasty were performed in six patients. The mean pressure gradient decreased from 14.5 mmHg to 2.8 mmHg before and after treatment, respectively. The follow up periods ranged from three months to 64 months (mean period; 32 months). Portal venous patency was maintained in all six patients until the final follow up. Combined hepatic venous stenosis was seen in one patient who was treated with stent placement. One patient showed puncture tract bleeding, and this patient was treated with coil embolization of the right portal puncture tract via the left transhepatic portal venous approach. Percutaneous transhepatic balloon angioplasty is an effective treatment for the portal vein stenosis that occurs after liver transplantation, and our results showed good mid-term patency with using this technique.

  18. Mobile Portal Implementation Strategy

    DEFF Research Database (Denmark)

    Gao, Ping; Damsgaard, Jan

    2005-01-01

    Mobile portal plays an important role in mobile commerce market. Current literature focuses on static analysis on the value chain of mobile portals. This article provides a dynamic perspective on mobile portal strategy. Drawing upon network economics, we describe mobile portal implementation...... as a fourphase process. In different phase, a portal provider has various challenges to overcome and adopt diverse strategies, and correspondingly the regulator has different foci. The conceptual framework proposed in this article offers a basis for further analyses on the market dynamics of mobile commerce......, and can be generalized to studying other networked technologies...

  19. Roadside Tracker Portal-less Portal Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Ziock, Klaus-Peter [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cheriyadat, Anil M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bradley, Eric Craig [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cunningham, Mark F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Fabris, Lorenzo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Goddard, Jr, James Samuel [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hornback, Donald Eric [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Karnowski, Thomas Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kerekes, Ryan A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Newby, Jason [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2013-07-01

    This report documents the full development cycle of the Roadside Tracker (RST) Portal-less Portal monitor (Fig. 1) funded by DHS DNDO. The project started with development of a proof-of-feasibility proto-type, proceeded through design and construction of a proof-of-concept (POC) prototype, a test-and-evaluation phase, participation in a Limited Use Exercise that included the Standoff Radiation Detections Systems developed under an Advanced Technology Demonstration and concluded with participation in a Characterization Study conducted by DNDO.

  20. Total hepatofugal portal blood flow in cirrhosis demonstrated by transhepatic portography

    Energy Technology Data Exchange (ETDEWEB)

    Burcharth, F; Aagaard, J

    1988-01-01

    We investigated 108 patients with cirrhosis of the liver and portal hypertension by percutaneous transhepatic portography to demonstrate the occurrence and frequency of total hepatofugal portal blood flow. Sixteen patients (14.8%) had a total hepatofugal portal blood flow. The aetiology of portal hypertension and the portal pressure did not differ from that in the group of patients with hepatopetal portal blood flow. A significantly higher percentage of patients in the group with hepatofugal flow had gastro-oesophageal varices (P < 0.025). All patients with varices had bled. Half of the patients in the group with hepatofugal blood flow had a false splenoportographic diagnosis of portal vein thrombosis. In conclusion, total hepatofugal postal blood flow exists more often than hitherto assumed. Hepatofugal blood flow does not relieve portal hypertension nor prevent development of gastro-oesophageal varices or bleeding.

  1. IMPROVEMENT OF SCHISTOSOMAL PORTAL HYPERTENSIVE COLOPATHY AFTER SURGICAL TREATMENT

    Directory of Open Access Journals (Sweden)

    Maria Angelina Carvalho MIRANDA

    2013-04-01

    Full Text Available Context Data on vascular alterations in patients with hepatosplenic schistosomiasis and portal hypertensive colopathy and changes in these after surgery to decrease portal hypertension are limited. Objective The purpose of this study was to analyse the alterations of portal hypertensive colopathy previously and 6-12 months after splenectomy and gastric devascularization. Methods Twelve patients with hepatosplenic schistosomiasis who also had upper gastrointestinal bleeding were studied prospectively. Their endoscopic findings before and 6-12 months after the surgery were analysed. In addition, mucosal biopsies from ascending colon, sigmoid colon and rectum at these time points were subjected to histological and histomorphometric assessment. It was used a control group due to lack of normal pattern of the histomorphometric measures of vessels in individuals without portal hypertension. The critical level of significance adopted in all tests was of a maximum probability error of 5%. Results Surgery did not lead to significant improvement in histological and endoscopic findings. However, on histomorphometry, there was a significant decrease in the area, diameter and thickness of the vessels in mucosa at all colonic sites. Conclusion Surgery for decompression of schistosomal portal hypertension has a beneficial effect on the associated colopathy, being best indicated in patients with gastrointestinal bleeding and esophageal varices.

  2. Clinical evaluation of false-positive scintigraphic lesions of the left lobe in portal hypertension

    International Nuclear Information System (INIS)

    Takayasu, Kenichi; Moriyama, Noriyuki; Suzuki, Masao; Yamada, Tatsuya; Fukutake, Toshio.

    1982-01-01

    sup(99m)Tc-phytate liver scan and percutaneous transhepatic portography (PTP) were performed in 33 patients with portal hypertension due to various hepatic diseases. A defect or space occupying lesion in the left lobe on the scan in these patients was analysed with reference to portographic changes of the pars umbilicus of the left portal vein and the following results were obtained. 1) A false-positive defect on the scintigram was found in 6 (18.2%) of 33 patients, and portal vein pressure (PVP) was above 200 mmH 2 O in all 6 which constituted 21.4% of 28 with PVP above 200 mmH 2 O. 2) In five out of 6 patients with false-positive scan findings, the pars umbilicus was dilated to more than 25 x 15 mm in size, and it was huge and tortuous in 3 of them. 3) The mean PVP in the group with a false-positive scan tended to be higher than that in patients with no abnormalities on the scintigram. It was concluded that in reading of liver scintigrams in patients with portal hypertension, a dilated pars umbilicus and huge para-umbilical vein should be considered. (author)

  3. Novel Rat Model of Repetitive Portal Venous Embolization Mimicking Human Non-Cirrhotic Idiopathic Portal Hypertension.

    Science.gov (United States)

    Klein, Sabine; Hinüber, Christian; Hittatiya, Kanishka; Schierwagen, Robert; Uschner, Frank Erhard; Strassburg, Christian P; Fischer, Hans-Peter; Spengler, Ulrich; Trebicka, Jonel

    2016-01-01

    Non-cirrhotic idiopathic portal hypertension (NCIPH) is characterized by splenomegaly, anemia and portal hypertension, while liver function is preserved. However, no animal models have been established yet. This study assessed a rat model of NCIPH and characterized the hemodynamics, and compared it to human NCIPH. Portal pressure (PP) was measured invasively and coloured microspheres were injected in the ileocecal vein in rats. This procedure was performed weekly for 3 weeks (weekly embolization). Rats without and with single embolization served as controls. After four weeks (one week after last embolization), hemodynamics were investigated, hepatic fibrosis and accumulation of myofibroblasts were analysed. General characteristics, laboratory analyses and liver histology were collected in patients with NCIPH. Weekly embolization induced a hyperdynamic circulation, with increased PP. The mesenteric flow and hepatic hydroxyproline content was significantly higher in weekly embolized compared to single embolized rats (mesenteric flow +54.1%, hydroxyproline +41.7%). Mesenteric blood flow and shunt volumes increased, whereas splanchnic vascular resistance was decreased in the weekly embolization group. Fibrotic markers αSMA and Desmin were upregulated in weekly embolized rats. This study establishes a model using repetitive embolization via portal veins, comparable with human NCIPH and may serve to test new therapies.

  4. Murine study of portal hypertension associated endothelin-1 hypo-response.

    Science.gov (United States)

    Theodorakis, Nicholas; Maluccio, Mary; Skill, Nicholas

    2015-04-28

    To investigate endothelin-1 hypo-responsive associated with portal hypertension in order to improve patient treatment outcomes. Wild type, eNOS(-/-) and iNOS(-/-) mice received partial portal vein ligation surgery to induce portal hypertension or sham surgery. Development of portal hypertension was determined by measuring the splenic pulp pressure, abdominal aortic flow and portal systemic shunting. To measure splenic pulp pressure, a microtip pressure transducer was inserted into the spleen pulp. Abdominal aortic flow was measured by placing an ultrasonic Doppler flow probe around the abdominal aorta between the diaphragm and celiac artery. Portal systemic shunting was calculated by injection of fluorescent microspheres in to the splenic vein and determining the percentage accumulation of spheres in liver and pulmonary beds. Endothelin-1 hypo-response was evaluated by measuring the change in abdominal aortic flow in response to endothelin-1 intravenous administration. In addition, thoracic aorta endothelin-1 contraction was measured in 5 mm isolated thoracic aorta rings ex-vivo using an ADI small vessel myograph. In wild type and iNOS(-/-) mice splenic pulp pressure increased from 7.5 ± 1.1 mmHg and 7.2 ± 1 mmHg to 25.4 ± 3.1 mmHg and 22 ± 4 mmHg respectively. In eNOS(-/-) mice splenic pulp pressure was increased after 1 d (P = NS), after which it decreased and by 7 d was not significantly elevated when compared to 7 d sham operated controls (6.9 ± 0.6 mmHg and 7.3 ± 0.8 mmHg respectively, P = 0.3). Abdominal aortic flow was increased by 80% and 73% in 7 d portal vein ligated wild type and iNOS when compared to shams, whereas there was no significant difference in 7 d portal vein ligated eNOS(-/-) mice when compared to shams. Endothelin-1 induced a rapid reduction in abdominal aortic blood flow in wild type, eNOS(-/-) and iNOS(-/-) sham mice (50% ± 8%, 73% ± 9% and 47% ± 9% respectively). Following portal vein ligation endothelin-1 reduction in blood flow

  5. CT findings of portal vein aneurysm

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Chang, Mi Son; Yoon, Myung Hwan; Kim, Hak Soo; Kim, Hyung Sik; Chung, Hyo Sun; Chung, Jin Woo

    1999-01-01

    To describe the CT findings of portal vein aneurysm in eight patients. All patients included in this study (two men and six women) underwent CT examinations between October 1996 and June1998. Of these eight, three were suffering from hepatic disease and portal hypertension. We determined the location, shape, size, and characteristics of the lesions, and the presence or absence of portal vein anomaly. Seven patients had intrahepatic portal vein aneurysm (at the umbilical portion of the left portal vein in five patients, between the transverse and umbilical portion of the left portal vein in one, and at the bifurcation of the anterior and posterior branch of the right portal vein in one), while extrahepatic portal vein aneurysm, at the confluence of the superior mesenteric and splenic vein was found in only one. Lesions were cyst-shaped in seven cases and saccular in one, and showed well-circumscribed, markedly enhanced mass, which communicated with the portal vein and/or gives off major branches. Portal vein anomaly, in which the right anterior segmental portal vein originated from the umbilical portion of the left portal vein, was seen in three patients. In all three, intrahepatic portal vein aneurysm was present at the umbilical portion of the left portal vein, and in one, the umbilical protion of the left portal vein was located to the right of the Cantlic line. CT examination can help reveal portal vein aneurysm by detecting a well-circumscribed, markedly enhanced mass which communicates with the portal vein and/or gives off major branches

  6. Systemic mastocytosis: A rare cause of non-cirrhotic portal hypertension.

    Science.gov (United States)

    Martins, Cláudio; Teixeira, Cristina; Ribeiro, Suzane; Trabulo, Daniel; Cardoso, Cláudia; Mangualde, João; Freire, Ricardo; Gamito, Élia; Alves, Ana Luísa; Cremers, Isabelle; Alves, Cecília; Neves, Anabela; Oliveira, Ana Paula

    2016-07-28

    Mastocytosis is a clonal neoplastic disorder of the mast cells (MC) that can be limited to the skin (cutaneous mastocytosis) or involve one or more extracutaneous organs (systemic mastocytosis). The clinical manifestations of mastocytosis are heterogeneous ranging from indolent disease with a long-term survival to a highly aggressive neoplasm with survival of about 6 mo. Although liver involvement in aggressive systemic mastocytosis (ASM) is relatively common, the development of portal hypertension with or without cirrhosis is rare. We report a case of ASM without skin involvement in a 72-year-old caucasian male who presented with non-cirrhotic portal hypertension based on clinical, analytical, imagiological and endoscopic findings. Given the hematological picture, the correct diagnosis was established based on ancillary tests for MC using bone marrow aspirates and biopsy. Extensive involvement of the liver and gastrointestinal tract was histologically documented. The disease progressed rapidly and severe pancytopenia and recurrent upper gastrointestinal bleeding became the dominant problem. This case illustrates the challenge in establishing a diagnosis of ASM especially when the clinical picture is atypical and without skin involvement. Gastroenterologists should consider infiltrative disease, particularly systemic mastocytosis, as a differential diagnosis in a clinical case of portal hypertension of unknown etiology.

  7. Evaluation of the portal venous system using MR angiography in patients with severe liver dysfunction

    International Nuclear Information System (INIS)

    Fukatsu, Hiroshi; Ando, Yoko; Yamakawa, Koji; Ishigaki, Takeo

    1994-01-01

    Fifteen patients of chronic liver dysfunction were examined with 2D TOF MR angiography to assess the portal venous system condition. All of the collateral pathways except esophageal varices were clearly demonstrated in all cases, portal vein thromboses were accurately diagnosed in two cases. Portal vein visualization index were determined as follows: good delineation of the main portal vein only; good delineation of the first tributaries of the intrahepatic portal vein; good delineation of the second or further tributaries. This index showed good correlation with the clinical stage proposed by Japan liver cancer study group. These results suggested that MR angiography has a potential for the evaluation of the portal system in patients with severe liver dysfunction. (author)

  8. Correlation between liver morphology and portal pressure in alcoholic liver disease

    DEFF Research Database (Denmark)

    Krogsgaard, K; Gluud, C; Henriksen, J H

    1984-01-01

    destruction and both wedged hepatic vein pressure (r = 0.72, p less than 0.01) and wedged-to-free hepatic vein pressure (r = 0.67, p less than 0.02). Degree of fatty change, fibrosis, inflammation, necrosis and occurrence of Mallory bodies showed no correlation with portal pressure. After morphometrical...... evaluation of liver biopsies, no significant correlation was found between mean hepatocyte volume or relative sinusoidal vascular volume and portal pressure. To test whether an increase in hepatocyte volume compresses the vascular structures and causes portal hypertension, the ratio of relative sinusoidal...... vascular volume to mean hepatocyte volume, which expresses the compression of the vascular structures exerted by enlargement of hepatocytes, was related to portal pressure. No significant correlation was found. Further, mean hepatocyte volume was not significantly correlated to relative sinusoidal vascular...

  9. Natural history of patients with non cirrhotic portal hypertension: Comparison with patients with compensated cirrhosis.

    Science.gov (United States)

    Gioia, Stefania; Nardelli, Silvia; Pasquale, Chiara; Pentassuglio, Ilaria; Nicoletti, Valeria; Aprile, Francesca; Merli, Manuela; Riggio, Oliviero

    2018-01-31

    The knowledge of natural history of patients with portal hypertension (PH) not due to cirrhosis is less well known than that of cirrhotic patients. To describe the clinical presentation and the outcomes of 89 patients with non-cirrhotic PH (25 with non-cirrhotic portal hypertension, INCPH, and 64 with chronic portal vein thrombosis, PVT) in comparison with 77 patients with Child A cirrhosis. The patients were submitted to a standardized clinical, laboratory, ultrasonographic and endoscopic follow-up. Variceal progression, incidence of variceal bleeding, portal vein thrombosis, ascites and survival were recorded. At presentation, the prevalence of varices, variceal bleeding and ascites was similar in the 3 groups. During follow-up, the rate of progression to varices at risk of bleeding (p portal hypertension in these patients and cannot be simply derived by the observation of cirrhotic patients. Copyright © 2018 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  10. A nationwide Dutch study regarding treatment portals for elective neck irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Van Dieren, E B [Integraal Kankercentrum, Rotterdam (Netherlands); Nowak, P J.C.M.; Van Soernsen de Koste, J.R.; Van Est, H; Heijmen, B J.M.; Levendag, P C

    1995-12-01

    The variation in treatment portals for elective radiotherapy of the neck, and the three-dimensional dosimetric consequences of this variation was assessed. Therefore, 16 experienced radiation oncologists from all major head and neck cooperative groups in the Netherlands (n=11) were asked to define RT-portals on a lateral and/or AP simulation film, for (routine) elective neck irradiation for a T2 tumor of the mobile tongue and a T3 tumor of the supraglottic larynx. Treatment portals were compared and evaluated using a three-dimensional treatment planning system and CT data with contoured critical structures and target volume. The CT-defined clinical target volume was mutually agreed upon by ENT-surgeons and radiation oncologists. Large differences were seen in treated volume (a factor of five). In addition, due to the variation in the cranial boundary of the RT-portals, the estimated NTCP varied considerably (0-50%). Moreover, several of the RT-portals did not adequately cover the CT-defined target volume. Even amongst experienced head and neck radiation oncologists, little agreement was observed with respect to treatment technique and size of the treatment portals in case of elective neck irradiation. This results in a considerable variation in treated volume. As a consequence, a large difference exists in the anticipated probability of normal tissue complication, and possibly in tumor control probability. Therefore, a definition of target volume and, consequently, a standardization of elective neck portals in mandatory. This is even more important if the primary tumor and clinically node-negative neck are to be treated by 3D conformal RT using multiple CT-slices for target delineation and positioning of BEV blocks in order to spare the normal tissue function with maximum tumor control probability.

  11. A nationwide Dutch study regarding treatment portals for elective neck irradiation

    International Nuclear Information System (INIS)

    Van Dieren, E.B.; Nowak, P.J.C.M.; Van Soernsen de Koste, J.R.; Van Est, H.; Heijmen, B.J.M.; Levendag, P.C.

    1995-01-01

    The variation in treatment portals for elective radiotherapy of the neck, and the three-dimensional dosimetric consequences of this variation was assessed. Therefore, 16 experienced radiation oncologists from all major head and neck cooperative groups in the Netherlands (n=11) were asked to define RT-portals on a lateral and/or AP simulation film, for (routine) elective neck irradiation for a T2 tumor of the mobile tongue and a T3 tumor of the supraglottic larynx. Treatment portals were compared and evaluated using a three-dimensional treatment planning system and CT data with contoured critical structures and target volume. The CT-defined clinical target volume was mutually agreed upon by ENT-surgeons and radiation oncologists. Large differences were seen in treated volume (a factor of five). In addition, due to the variation in the cranial boundary of the RT-portals, the estimated NTCP varied considerably (0-50%). Moreover, several of the RT-portals did not adequately cover the CT-defined target volume. Even amongst experienced head and neck radiation oncologists, little agreement was observed with respect to treatment technique and size of the treatment portals in case of elective neck irradiation. This results in a considerable variation in treated volume. As a consequence, a large difference exists in the anticipated probability of normal tissue complication, and possibly in tumor control probability. Therefore, a definition of target volume and, consequently, a standardization of elective neck portals in mandatory. This is even more important if the primary tumor and clinically node-negative neck are to be treated by 3D conformal RT using multiple CT-slices for target delineation and positioning of BEV blocks in order to spare the normal tissue function with maximum tumor control probability

  12. Perivesical varices and portal hypertension: imaging study

    International Nuclear Information System (INIS)

    Mallorquin Jimenez, F.; Medina Benitez, A.; Lopez Machado, E.; Pardo Moreno, M.D.; Garrido Moreno, C.; Pastor Rull, J.

    1995-01-01

    Nine patients with portal hypertension syndrome and Perivesical varices are studied retrospectively by means of imaging techniques including ultrasound, duplex Doppler, color Doppler, CT and angiography. All the patients presented portal thrombosis and thickening of the bladder wall. These collaterals either represent a shunting of hepato pedal flow or correspond to blood stasis associated with said syndrome. Ultrasound, whether involving duplex Doppler or color Doppler techniques, is highly useful to detect the presence of Perivesical varices which appear as tubular or rounded hypo echogenic areas in the bladder wall. Given the association of this entity with bladder wall thickening, it should be taken into account in any clinical situation involving said change, especially in patients with portal hypertension; moreover knowledge of its presence is of great importance when the possibility of creating shunts by means of interventional or surgical vascular procedures or other types of abdominal procedures are being considered because of the risk of bleeding. (Author)

  13. Ethanol-induced increase in portal blood glow: Role of adenosine

    International Nuclear Information System (INIS)

    Orrego, H.; Carmichael, F.J.; Saldivia, V.; Giles, H.G.; Sandrin, S.; Israel, Y.

    1988-01-01

    The mechanism by which ethanol induces an increase in portal vein blood flow was studied in rats using radiolabeled microspheres. Ethanol by gavage resulted in an increase of 50-70% in portal vein blood flow. The ethanol-induced increase in portal blood flow was suppressed by the adenosine receptor blocker 8-phenyltheophylline. By itself, 8-phenyltheophylline was without effect on cardiac output or portal blood flow. Adenosine infusion resulted in a dose-dependent increase in portal blood flow. This adenosine-induced increase in portal blood flow was inhibited by 8-phenyltheophylline in a dose-dependent manner. Both alcohol and adenosine significantly reduced preportal vascular resistance by 40% and 60%, respectively. These effects were fully suppressed by 8-phenyltheophylline. It is concluded that adenosine is a likely candidate to mediate the ethanol-induced increase in portal vein blood flow. It is suggested that an increase in circulating acetate and liver hypoxia may mediate the effects of alcohol by increasing tissue and interstitial adenosine levels

  14. Extrahepatic portal hypertension in childhood

    International Nuclear Information System (INIS)

    Takehara, Hiroo; Komi, Nobuhiko; Goh, Masahiro; Yoshida, Sadahiro; Kameoka, Kazuhiro; Hino, Masao; Sui, Osamu

    1986-01-01

    Four pediatric patients with extrahepatic portal hypertension had undergone portography and computerized radionuclide angiography in order to examine shape of portal system and to evaluate hepatic blood flow before and aftersurgical treatment. In all patients, cavernous transformation of portal system was demonstrated by portography, and in one of them spontaneous splenorenal shunt occurred. In 3 of them, who underwent esophageal transsection combined with paraesophagogastric devascularization and splenectomy, so-called direct operation, increase of portal blood flow was revealed by computerized radionuclide angiography. It is suggested that direct operation increasing portal blood flow after surgery is effective in treating extrahepatic portal hypertension in childhood. (author)

  15. Indocyanine green retention test (ICG-r15) as a noninvasive predictor of portal hypertension in patients with different severity of cirrhosis.

    Science.gov (United States)

    Pind, Marie-Louise L; Bendtsen, Flemming; Kallemose, Thomas; Møller, Søren

    2016-08-01

    Portal hypertension is a severe consequence of chronic liver disease, responsible for the main clinical complications of cirrhosis. Measurement of the hepatic venous pressure gradient (HVPG) provides important clinical information, but the procedure is invasive and demands expert skills of the staff.In the present study, we aimed to investigate the relationship between the constant infusion indocyanine green (ICG) clearance, the calculated ICG retention test after 15 min (ICG-r15), and HVPG in patients with different severity of cirrhosis for validation of ICG-r15 as a noninvasive predictor of portal hypertension. A total of 325 patients were studied. During a hemodynamic investigation, the ICG clearance was determined using the constant infusion technique and ICG-r15 was calculated. Assessment of the diagnostic performance of ICG clearance and ICG-r15 as predictors of HVPG above 10 mmHg was performed by receiver operating characteristic curve analyses.The ICG clearance and ICG-r15 performed well in all three Child classes, with the most significant results among Child class A patients [area under the receiver operating characteristic (AUROC)=0.832] and less significant results in Child class B (AUROC=0.7448) and Child class C patients (AUROC=0.7392). Only six out of 102 patients in Child class C had HVPG of less than 12 mmHg. ICG-r15 can be used as an indirect assessment of significant portal hypertension in compensated cirrhotic patients. ICG-r15 may be suitable as a screening tool for the identification of patients for endoscopy and measurement of HVPG.Further validation of ICG-r15 together with other predictors of portal hypertension and its clinical use is encouraged.

  16. Vasopressin-induced changes in splanchnic blood flow and hepatic and portal venous pressures in liver resection.

    Science.gov (United States)

    Bown, L Sand; Ricksten, S-E; Houltz, E; Einarsson, H; Söndergaard, S; Rizell, M; Lundin, S

    2016-05-01

    To minimize blood loss during hepatic surgery, various methods are used to reduce pressure and flow within the hepato-splanchnic circulation. In this study, the effect of low- to moderate doses of vasopressin, a potent splanchnic vasoconstrictor, on changes in portal and hepatic venous pressures and splanchnic and hepato-splanchnic blood flows were assessed in elective liver resection surgery. Twelve patients were studied. Cardiac output (CO), stroke volume (SV), mean arterial (MAP), central venous (CVP), portal venous (PVP) and hepatic venous pressures (HVP) were measured, intraoperatively, at baseline and during vasopressin infusion at two infusion rates (2.4 and 4.8 U/h). From arterial and venous blood gases, the portal (splanchnic) and hepato-splanchnic blood flow changes were calculated, using Fick's equation. CO, SV, MAP and CVP increased slightly, but significantly, while systemic vascular resistance and heart rate remained unchanged at the highest infusion rate of vasopressin. PVP was not affected by vasopressin, while HVP increased slightly. Vasopressin infusion at 2.4 and 4.8 U/h reduced portal blood flow (-26% and -37%, respectively) and to a lesser extent hepato-splanchnic blood flow (-9% and -14%, respectively). The arterial-portal vein lactate gradient was not significantly affected by vasopressin. Postoperative serum creatinine was not affected by vasopressin. Short-term low to moderate infusion rates of vasopressin induced a splanchnic vasoconstriction without metabolic signs of splanchnic hypoperfusion or subsequent renal impairment. Vasopressin caused a centralization of blood volume and increased cardiac output. Vasopressin does not lower portal or hepatic venous pressures in this clinical setting. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. Usability of Discovery Portals

    NARCIS (Netherlands)

    Bulens, J.D.; Vullings, L.A.E.; Houtkamp, J.M.; Vanmeulebrouk, B.

    2013-01-01

    As INSPIRE progresses to be implemented in the EU, many new discovery portals are built to facilitate finding spatial data. Currently the structure of the discovery portals is determined by the way spatial data experts like to work. However, we argue that the main target group for discovery portals

  18. Osteopontin: A non-invasive parameter of portal hypertension and prognostic marker of cirrhosis.

    Science.gov (United States)

    Bruha, Radan; Jachymova, Marie; Petrtyl, Jaromir; Dvorak, Karel; Lenicek, Martin; Urbanek, Petr; Svestka, Tomislav; Vitek, Libor

    2016-03-28

    To investigate the relationship between osteopontin plasma concentrations and the severity of portal hypertension and to assess osteopontin prognostic value. A cohort of 154 patients with confirmed liver cirrhosis (112 ethylic, 108 men, age 34-72 years) were enrolled in the study. Hepatic venous pressure gradient (HVPG) measurement and laboratory and ultrasound examinations were carried out for all patients. HVPG was measured using a standard catheterization method with the balloon wedge technique. Osteopontin was measured using the enzyme-linked immunosorbent assay (ELISA) method in plasma. Patients were followed up with a specific focus on mortality. The control group consisted of 137 healthy age- and sex- matched individuals. The mean value of HVPG was 16.18 ± 5.6 mmHg. Compared to controls, the plasma levels of osteopontin in cirrhotic patients were significantly higher (P portal hypertension (HVPG above 10 mmHg) at 75% sensitivity and 63% specificity. The mean follow-up of patients was 3.7 ± 2.6 years. The probability of cumulative survival was 39% for patients with HVPG > 10 mmHg and 65% for those with HVPG ≤ 10 mmHg (P = 0.0086, odds ratio (OR), 2.92, 95% confidence interval (CI): 1.09-7.76). Osteopontin showed a similar prognostic value to HVPG. Patients with osteopontin values above 80 ng/mL had significantly lower cumulative survival compared to those with osteopontin ≤ 80 ng/mL (37% vs 56%, P = 0.00035; OR = 2.23, 95%CI: 1.06-4.68). Osteopontin is a non-invasive parameter of portal hypertension that distinguishes patients with clinically significant portal hypertension. It is a strong prognostic factor for survival.

  19. The Knowledge Portal

    Data.gov (United States)

    Office of Personnel Management — Information on various courses, as well as personal data of employees and training records from The Knowledge Portal (TKP), a web-based training portal used for the...

  20. Design simplicity influences patient portal use: the role of aesthetic evaluations for technology acceptance

    Science.gov (United States)

    Watkins, Ivan; Mackert, Michael S; Xie, Bo; Stephens, Keri K; Shalev, Heidi

    2016-01-01

    Objective This study focused on patient portal use and investigated whether aesthetic evaluations of patient portals function are antecedent variables to variables in the Technology Acceptance Model. Methods A cross-sectional survey of current patient portals users (N = 333) was conducted online. Participants completed the Visual Aesthetics of Website Inventory, along with items measuring perceived ease of use (PEU), perceived usefulness (PU), and behavioral intentions (BIs) to use the patient portal. Results The hypothesized model accounted for 29% of the variance in BIs to use the portal, 46% of the variance in the PU of the portal, and 29% of the variance in the portal’s PEU. Additionally, one dimension of the aesthetic evaluations functions as a predictor in the model – simplicity evaluations had a significant positive effect on PEU. Conclusion This study provides evidence that aesthetic evaluations – specifically regarding simplicity – function as a significant antecedent variable to patients’ use of patient portals and should influence patient portal design strategies. PMID:26635314

  1. Computed tomographic and ultrasonographic diagnosis of portal vein tumor thrombus in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Mori, H; Futagawa, S; Hayashi, K; Amagasaki, Y; Ochi, M [Nagasaki Univ. (Japan). School of Medicine

    1982-04-01

    Nine cases of hepatocellular carcinoma which have invaded the intra- and extrahepatic portal vein were evaluated by computed tomography (CT) and ultrasonography (US). The outstanding CT and sonographic features of the portal vein tumor thrombus were described. In CT, contrast opacification of normal portal vein and its major tributaries were not observed, and they were replaced by a soft tissue density mass representing the tumor thrombus. The thrombus measured 35 - 45 Hounsfield units (HU) in precontrast scans and 60 - 80 HU in postcontrast scans. The portal vein tumor thrombus showed a branched pattern of low density in porta hepatis and intrahepatic region due to differences in attenuation coefficients of the thrombus and adjacent noncancerous hepatic parenchyma on postcontrast scans. In ultrasound study, tumor thrombus was recognized as an echogenic solid mass in the porta hepatis obliterating the normal portal venous structures, or as an intraluminal solid mass in the dilated portal vein and its branches. Numerous collateral venous channels surrounding the thrombosed portal vein were also demonstrated on both CT and US. Particular emphasis was placed on the clinical implications of these non-invasive detection of the portal vein tumor thrombosis in patients with hepatocellular carcinoma.

  2. Portals people, processes, technology

    CERN Document Server

    Cox, Andrew

    2006-01-01

    First applied to internet gateways such as Yahoo, the concept of the ""portal"" has evolved in a number of directions. How can information services best take advantage of internet portals to improve access to resources? This collection seeks answers to such questions, providing an overview of how portals are being used.

  3. Histological Spectrum of Idiopathic Noncirrhotic Portal Hypertension in Liver Biopsies From Dialysis Patients.

    Science.gov (United States)

    Lee, Hwajeong; Ainechi, Sanaz; Singh, Mandeep; Ells, Peter F; Sheehan, Christine E; Lin, Jingmei

    2015-09-01

    Liver biopsy is performed for various indications in dialysis patients. Being a less-common subset, the hepatic pathology in renal dialysis is not well documented. Idiopathic noncirrhotic portal hypertension (INCPH) is a clinical entity associated with unexplained portal hypertension and/or a spectrum of histopathological vascular changes in the liver. After encountering INCPH and vascular changes of INCPH in 2 renal dialysis patients, we sought to further investigate this noteworthy association. A random search for patients on hemodialysis or peritoneal dialysis with liver biopsy was performed. Hematoxylin and eosin, reticulin, trichrome, and CK7 stains were performed on formalin-fixed, paraffin-embedded tissue sections. Histopathological features were reviewed, and the results were correlated with clinical findings. In all, 13 liver biopsies were retrieved. The mean cumulative duration of dialysis was 50 months (range = 17 months to 11 years). All patients had multiple comorbidities. Indications for biopsy were a combination of abnormal liver function tests (6), portal hypertension (4), ascites (3), and possible cirrhosis (3). Two patients with portal hypertension underwent multiple liver biopsies for diagnostic purposes. All (100%) biopsies showed some histological features of INCPH, including narrowed portal venous lumen (9), increased portal vascular channels (8), shunt vessels (3), dilated sinusoids (9), regenerative nodule (5), and features of venous outflow obstruction (3). No cirrhosis was identified. Liver biopsies from patients on dialysis demonstrate histopathological vascular changes of INCPH. Some (31%) patients present with portal hypertension without cirrhosis. The histological changes may be reflective of underlying risk factors for INCPH in this group. © The Author(s) 2015.

  4. [Emphysematous gastritis with concomitant portal venous air].

    Science.gov (United States)

    Jeong, Min Yeong; Kim, Jin Il; Kim, Jae Young; Kim, Hyun Ho; Jo, Ik Hyun; Seo, Jae Hyun; Kim, Il Kyu; Cheung, Dae Young

    2015-02-01

    Emphysematous gastritis is a rare form of gastritis caused by infection of the stomach wall by gas forming bacteria. It is a very rare condition that carries a high mortality rate. Portal venous gas shadow represents elevation of intestinal luminal pressure which manifests as emphysematous gastritis or gastric emphysema. Literature reviews show that the mortality rate is especially high when portal venous gas shadow is present on CT scan. Until recently, the treatment of emphysematous gastritis has been immediate surgical intervention. However, there is a recent trend of avoiding surgery because of the frequent occurrence of post-operative complications such as anastomosis leakage. In addition, aggressive surgical treatment has failed to show significant improvement in prognosis. Recently, the authors experienced a case of emphysematous gastritis accompanied by portal venous gas which was treated successfully by conservative treatment without immediate surgical intervention. Herein, we present a case of emphysematous gastritis with concomitant portal venous air along with literature review.

  5. Liver perfusion scintigraphy prior to and after transjugular intrahepatic portosystemic shunts (TIPS) in patients with portal hypertension

    International Nuclear Information System (INIS)

    Willkomm, P.; Schomburg, A.; Reichmann, K.; Bangard, M.; Overbeck, B.; Biersack, H.J.; Brensing, K.A.; Sauerbruch, T.

    2000-01-01

    Purpose: This investigation was performed to compare the hemodynamic results of the transjugular intrahepatic portosystemic shunt, a new interventional treatment for portal hypertension, with those observed after the established surgical shunt interventions. Methods: We examined 22 patients with portal hypertension due to liver cirrhosis before and after elective TIPS by liver perfusion scintigraphy. The relative portal perfusion was determined before and after the shunt procedure. Additionally, we measured the portal pressure gradient (PPG: Portal-central venous pressure, mmHg). Results: Prior to TIPS, the relative portal perfusion was significantly reduced to 22±9.1%. After the intervention we calculated values of 23.1±10.7% in the TIPS-group (p=0.67; not significant). In spite of unchanged portal perfusion, the portal pressure was significantly (p [de

  6. SU-F-T-272: Patient Specific Quality Assurance of Prostate VMAT Plans with Portal Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Darko, J; Osei, E [Grand River Cancer Centre @ Grand River Hospital, Kitchener, ON (Canada); University of Waterloo, Waterloo, ON (Canada); Kiciak, A [University of Waterloo, Waterloo, ON (Canada); Badu, S; Grigorov, G; Fleck, A [Grand River Cancer Centre @ Grand River Hospital, Kitchener, ON (Canada)

    2016-06-15

    Purpose: To evaluate the effectiveness of using the Portal Dosimetry (PD) method for patient specific quality assurance of prostate VMAT plans. Methods: As per institutional protocol all VMAT plans were measured using the Varian Portal Dosimetry (PD) method. A gamma evaluation criterion of 3%-3mm with a minimum area gamma pass rate (gamma <1) of 95% is used clinically for all plans. We retrospectively evaluated the portal dosimetry results for 170 prostate patients treated with VMAT technique. Three sets of criterions were adopted for re-evaluating the measurements; 3%-3mm, 2%-2mm and 1%-1mm. For all criterions two areas, Field+1cm and MLC-CIAO were analysed.To ascertain the effectiveness of the portal dosimetry technique in determining the delivery accuracy of prostate VMAT plans, 10 patients previously measured with portal dosimetry, were randomly selected and their measurements repeated using the ArcCHECK method. The same criterion used in the analysis of PD was used for the ArcCHECK measurements. Results: All patient plans reviewed met the institutional criteria for Area Gamma pass rate. Overall, the gamma pass rate (gamma <1) decreases for 3%-3mm, 2%-2mm and 1%-1mm criterion. For each criterion the pass rate was significantly reduced when the MLC-CIAO was used instead of FIELD+1cm. There was noticeable change in sensitivity for MLC-CIAO with 2%-2mm criteria and much more significant reduction at 1%-1mm. Comparable results were obtained for the ArcCHECK measurements. Although differences were observed between the clockwise verses the counter clockwise plans in both the PD and ArcCHECK measurements, this was not deemed to be statistically significant. Conclusion: This work demonstrates that Portal Dosimetry technique can be effectively used for quality assurance of VMAT plans. Results obtained show similar sensitivity compared to ArcCheck. To reveal certain delivery inaccuracies, the use of a combination of criterions may provide an effective way in improving

  7. The keys to successful TIPS in patients with portal vein thrombosis and cavernous transformation.

    Science.gov (United States)

    Lombardo, S; Espejo, J J; Pérez-Montilla, M E; Zurera, L J; González-Galilea, Á

    Portal vein thrombosis is a common complication in patients with cirrhosis. Anticoagulation involves a high risk of bleeding secondary to portal hypertension, so placing transjugular intrahepatic portosystemic shunts (TIPS) has become an alternative treatment for portal vein thrombosis. Three strategies for TIPS placement have been reported: 1) portal recanalization and conventional implantation of the TIPS through the jugular vein; 2) portal recanalization through percutaneous transhepatic/transsplenic) access; and (3) insertion of the TIPS between the suprahepatic vein and a periportal collateral vessel without portal recanalization. We describe different materials that can be used as fluoroscopic targets for the TIPS needle and for portal recanalization. This article aims to show the success of TIPS implantation using different combinations of the techniques listed above, which is a good treatment alternative in these patients whose clinical condition makes them difficult to manage, and to show that portal vein thrombosis/cavernous transformation should not be considered a contraindication for TIPS. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Splenic embolization in cirrhotic patients with portal hypertension

    International Nuclear Information System (INIS)

    Falappa, P.G.; Cotroneo, A.R.; De Cinque, M.; Maresca, G.; Patane', D.

    1988-01-01

    Over the last four years the authors performed transcatheter embolization of the splenic artery by Gianturco coils in 32 consecutive cirrhotic patients with portal hypertension, splenomegaly, cytopenia and gastro-esophageal varices endoscopically proved. This procedure was especially useful for treatement of splenomegaly and cytopenia because a constant reduction of spleen dimensions and increase in platelet count were registered. The effectiveness of transcatheter embolization and follow-up are based on clinic, hematologic and sonographic findings. Sonographic monitoring is believed to be very useful both to evaluate splenomegaly and signs of portal hypertension and to reveal splenic complications (abscesses). Severe complications have been never registered

  9. Contrast-enhanced sonography for quantitative assessment of portal hypertension in patients with liver cirrhosis.

    Science.gov (United States)

    Qu, En-Ze; Zhang, Ying-Cai; Li, Zhi-Yan; Liu, Yang; Wang, Jin-Rui

    2014-11-01

    The clinical utility of contrast-enhanced sonography in portal hypertension remains unclear. We explored the feasibility of using contrast-enhanced sonography for noninvasive assessment of portal venous pressure. Twenty healthy individuals (control group; 9 men; mean age, 46.4 years) and 18 patients with portal hypertension (15 men; mean age, 46.2 years) were enrolled in this study. The portal hypertension group included patients who underwent splenectomy and pericardial blood vessel disarticulation at our hospital from October 2010 to March 2011. One week before surgery, patients with portal hypertension underwent preoperative liver contrast-enhanced sonography. Two-dimensional, Doppler, and contrast-enhanced sonographic parameters were compared between the groups. Portal venous pressure was measured intraoperatively by portal vein puncture in the portal hypertension group, and its relationship with the other parameters was analyzed. The 2-dimensional, Doppler, and contrast-enhanced sonographic parameters differed between the groups (P Portal venous pressure was inversely correlated with the area under the portal vein/hepatic artery time-intensity curve ratio (Qp/Qa), portal vein/hepatic artery strength ratio (Ip/Ia), and portal vein/hepatic artery wash-in perfusion slope ratio (βp/βa), with correlation coefficients of -0.701, -0.625, and -0.494, respectively. Measurement of the liver contrast-enhanced sonographic parameters Qp/Qa, Ip/Ia, and βp/βa could be used as a new quantitative method for noninvasively assessing portal venous pressure. © 2014 by the American Institute of Ultrasound in Medicine.

  10. Applications of portals in the energetic sector; Aplicaciones de portales en el sector energetico

    Energy Technology Data Exchange (ETDEWEB)

    Santos Dominguez, Martin; Arroyo Figueroa, Gustavo [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    2000-07-01

    An operative portal joins the applications, contents and services of the company in a single page of Intranet such way that promises to change deeply the information technology in the next years. The corporative portals will change what people visualize in the screen of their computer at the beginning of every working day. Unlike seeing the network (Web) only with pages of language of hypertext bearing (HTML), the corporative portal acts as a gate between Internet and the private networks. This article presents a general vision of the benefits of the corporative portals, the existing technologies and the potential markets. [Spanish] Un portal operativo une las aplicaciones, contenidos y servicios de la empresa en una sola pagina de Intranet, de tal forma que promete cambiar, profundamente la tecnologia de la informacion en los proximos anos. Los portales corporativos cambiaran lo que la gente visualiza en la pantalla de su computadora al comienzo de cada dia de trabajo. A diferencia de ver la red (Web) solo con paginas de lenguaje de marcacion de hipertexto (HTML), el portal corporativo actua como compuerta entre Internet y las redes privadas. Este articulo presenta una vision general de los beneficios de los portales corporativos, las tecnologias y los mercados potenciales existentes.

  11. Visualization of portal venous system by single photon emission CT

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, T; Ikawa, T; Azuma, M; Matsuda, H; Yoshioka, H; Mitsutani, N; Koizumi, T

    1987-03-01

    Single photon emission CT (SPECT) was performed for the intra-abdominal blood pool with /sup 99m/Tc autologous red blood cells (RBC) in 15 patients with liver cirrhosis. Twenty mCi of /sup 99m/Tc-RBC labeled by in vivo technique were administered intravenously and tomographic imaging of the intra-abdominal vascular blood pool was performed as follows. For each subject, 64 views were obtained over 360 deg of elliptic rotation at 30 seconds per view using a high resolution low energy parallel-hole collimator. Portal vein and portosystemic collaterals were clearly observed in coronal images. In 12 of 15 patients, portal vein was delineated. Portosystemic collaterals such as coronary vein, splenorenal shunt and umbilical vein were also shown in 12 patients. These images were consistent with images obtained by scintiphotosplenoportography or arterial portography. Therefore, it is considered that SPECT study for the intra-abdominal blood pool is clinically very useful for the diagnosis of abnormality of portal venous system in portal hypertension.

  12. Clinical evaluation of false-positive scintigraphic lesions of the left lobe in portal hypertension. Comparison with portographic findings of the pars umbilicus of the portal vein

    Energy Technology Data Exchange (ETDEWEB)

    Takayasu, Kenichi; Moriyama, Noriyuki; Suzuki, Masao; Yamada, Tatsuya [National Cancer Center, Tokyo (Japan). Hospital; Fukutake, Toshio

    1982-09-01

    sup(99m)Tc-phytate liver scan and percutaneous transhepatic portography (PTP) were performed in 33 patients with portal hypertension due to various hepatic diseases. A defect or space occupying lesion in the left lobe on the scan in these patients was analysed with reference to portographic changes of the pars umbilicus of the left portal vein and the following results were obtained. 1) A false-positive defect on the scintigram was found in 6 (18.2%) of 33 patients, and portal vein pressure (PVP) was above 200 mmH/sub 2/O in all 6 which constituted 21.4% of 28 with PVP above 200 mmH/sub 2/O. 2) In five out of 6 patients with false-positive scan findings, the pars umbilicus was dilated to more than 25 x 15 mm in size, and it was huge and tortuous in 3 of them. 3) The mean PVP in the group with a false-positive scan tended to be higher than that in patients with no abnormalities on the scintigram. It was concluded that in reading of liver scintigrams in patients with portal hypertension, a dilated pars umbilicus and huge para-umbilical vein should be considered.

  13. Anatomic relationship of intrahepatic bile ducts to portal veins revisited

    International Nuclear Information System (INIS)

    Bret, P.M.; Stempel, J.; Atri, M.; Lough, J.O.; Illescas, F.F.

    1987-01-01

    It is well accepted that intrahepatic bile ducts lie in front of corresponding portal vein branches. Since the authors' clinical experience with US was different, they studied 18 normal necropsy cadaver livers. The common bile duct, main portal vein, and hepatic artery were cannulated and injected respectively with air, dilute contrast medium, and mineral oil. The livers were then examined in anatomic position with CT. In the left lobe of the liver, the bile ducts were anterior to the portal vein in seven cases, posterior in seven cases, and were tortuous both anterior and posterior in three cases. In the right lobe, the bile ducts were anterior in nine cases, posterior in five cases, tortuous in one case, and not seen in two cases. In the porta hepatis, the bile ducts were anterior in eight cases, posterior in one case, tortuous in five cases, and not seen in three cases. Histologic specimens confirmed the anterior and posterior location of the bile ducts relative to the portal veins. In conclusion, intrahepatic bile ducts can be either anterior or posterior to the corresponding portal vein branches

  14. From EGEE Operations Portal towards EGI Operations Portal

    Science.gov (United States)

    Cordier, Hélène; L'Orphelin, Cyril; Reynaud, Sylvain; Lequeux, Olivier; Loikkanen, Sinikka; Veyre, Pierre

    Grid operators in EGEE have been using a dedicated dashboard as their central operational tool, stable and scalable for the last 5 years despite continuous upgrade from specifications by users, monitoring tools or data providers. In EGEE-III, recent regionalisation of operations led the Operations Portal developers to conceive a standalone instance of this tool. We will see how the dashboard reorganization paved the way for the re-engineering of the portal itself. The outcome is an easily deployable package customized with relevant information sources and specific decentralized operational requirements. This package is composed of a generic and scalable data access mechanism, Lavoisier; a renowned php framework for configuration flexibility, Symfony and a MySQL database. VO life cycle and operational information, EGEE broadcast and Downtime notifications are next for the major reorganization until all other key features of the Operations Portal are migrated to the framework. Features specifications will be sketched at the same time to adapt to EGI requirements and to upgrade. Future work on feature regionalisation, on new advanced features or strategy planning will be tracked in EGI- Inspire through the Operations Tools Advisory Group, OTAG, where all users, customers and third parties of the Operations Portal are represented from January 2010.

  15. [Treatment of nontumoral portal vein thrombosis in cirrhosis].

    Science.gov (United States)

    Bañares, Rafael; Catalina, María-Vega

    2014-07-01

    Portal vein thrombosis in cirrhosis is a relatively common complication associated with the presence of an accompanying prothrombotic phenotype of advanced cirrhosis. The consequences of portal vein thrombosis are relevant because it can be associated with impaired hepatic function, might contraindicate hepatic transplantation and could increase morbidity in the surgical procedure. There is controversy concerning the most effective treatment of portal vein thrombosis, which is based on information that is seldom robust and whose primary objective is to achieve a return to vessel patency. Various studies have suggested that starting anticoagulation therapy early is associated with portal vein repatency more frequently than without treatment and has a low rate of complications. There are no proven data on the type of anticoagulant (low-molecular-weight heparins or dicoumarin agents) and the treatment duration. The implementation of TIPS is technically feasible in thrombosis without cavernous transformation and is associated with portal vein recanalization in a significant proportion of cases. Thrombolytic therapy does not appear to present an adequate balance between efficacy and safety; its use is therefore not supported for this indication. The proper definition of treatment for portal vein thrombosis requires properly designed studies to delimit the efficacy and safety of the various alternatives. Copyright © 2014 Elsevier España, S.L. All rights reserved.

  16. Evaluation of portal hypertension in cirrhotic patients using color duplex-doppler ultrasound. Preliminary study; Evaluacion de la hipertension portal del cirrotico mediante ultrasonografia duplex-Doppler color. Estudio prliminar

    Energy Technology Data Exchange (ETDEWEB)

    Varas, M J; Torres, G; Sanllely, H [Unidad de Ecografias, Consorcio del Hospital de la Cruz Roja, L` Hospitalet de Llobregat, Barcelona (Spain)

    1996-09-01

    The objective was to compare data obtained by color duplex-Doppler ultrasound (mean velocity, flow and portal vein congestion index) in patients with chronic diffuse liver disease with and without portal hypertension (PH) (demonstrated endoscopically) with that of a healthy control group. Over a two-year period, 50 studies were performed in 10 healthy subjects (control group) with a mean age of 36 years and in 40 chronic liver disease patients (study group with a mean age of 58 years), most of whom presented alcoholic liver cirrhosis and belonged to Child-Pugh class B. They were subdivided according to endoscopic study into patients without (group 1) and with (group 2) portal hypertension. There were statistically significant differences in the diameters of splenic vein, spleen, portal vein and in the portal Vm, which decreased as the Child-Pugh score rose. When the patients without (group 1) and with (group 2) endoscopic evidence of PH (esophageal varices)were analyzed and compared, the two groups presented no statistically significant differences with respect to portal Vm, blood flow out of the liver, presence of collateral vessels, or the portal vein congestion index; the latter was significantly different in both the study group as a whole and in the patients with PH when compared with the control group. Given that this report is based on a pilot study which requires a larger sample number, we are unable to arrive at definitive conclusions. (Author) 18 refs.

  17. Contemporary concepts of the medical therapy of portal hypertension under liver cirrhosis.

    Science.gov (United States)

    Garbuzenko, Dmitry Victorovich

    2015-05-28

    Severe complications of liver cirrhosis are mostly related to portal hypertension. At the base of the pathogenesis of portal hypertension is the increase in hepatic vascular resistance to portal blood flow with subsequent development of hyperdynamic circulation, which, despite of the formation of collateral circulation, promotes progression of portal hypertension. An important role in its pathogenesis is played by the rearrangement of vascular bed and angiogenesis. As a result, strategic directions of the therapy of portal hypertension under liver cirrhosis include selectively decreasing hepatic vascular resistance with preserving or increasing portal blood flow, and correcting hyperdynamic circulation and pathological angiogenesis, while striving to reduce the hepatic venous pressure gradient to less than 12 mmHg or 20% of the baseline. Over the last years, substantial progress in understanding the pathophysiological mechanisms of hemodynamic disorders under liver cirrhosis has resulted in the development of new drugs for their correction. Although the majority of them have so far been investigated only in animal experiments, as well as at the molecular and cellular level, it might be expected that the introduction of the new methods in clinical practice will increase the efficacy of the conservative approach to the prophylaxis and treatment of portal hypertension complications. The purpose of the review is to describe the known methods of portal hypertension pharmacotherapy and discuss the drugs that may affect the basic pathogenetic mechanisms of its development.

  18. Assessment of contrast-enhanced ultrasonography of the hepatic vein for detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs.

    Science.gov (United States)

    Morishita, Keitaro; Hiramoto, Akira; Michishita, Asuka; Takagi, Satoshi; Hoshino, Yuki; Itami, Takaharu; Lim, Sue Yee; Osuga, Tatsuyuki; Nakamura, Sayuri; Ochiai, Kenji; Nakamura, Kensuke; Ohta, Hiroshi; Yamasaki, Masahiro; Takiguchi, Mitsuyoshi

    2017-04-01

    OBJECTIVE To assess the use of contrast-enhanced ultrasonography (CEUS) of the hepatic vein for the detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs. ANIMALS 6 healthy Beagles. PROCEDURES A prospective study was conducted. A catheter was surgically placed in the portal vein of each dog. Hypertension was induced by intraportal injection of microspheres (10 to 15 mg/kg) at 5-day intervals via the catheter. Microsphere injections were continued until multiple acquired portosystemic shunts were created. Portal vein pressure (PVP) was measured through the catheter. Contrast-enhanced ultrasonography was performed before and after establishment of hypertension. Time-intensity curves were generated from the region of interest in the hepatic vein. Perfusion variables measured for statistical analysis were hepatic vein arrival time, time to peak, time to peak phase (TTPP), and washout ratio. The correlation between CEUS variables and PVP was assessed by use of simple regression analysis. RESULTS Time to peak and TTPP were significantly less after induction of portal hypertension. Simple regression analysis revealed a significant negative correlation between TTPP and PVP. CONCLUSIONS AND CLINICAL RELEVANCE CEUS was useful for detecting hemodynamic changes associated with experimentally induced portal hypertension in dogs, which was characterized by a rapid increase in the intensity of the hepatic vein. Furthermore, TTPP, a time-dependent variable, provided useful complementary information for predicting portal hypertension. IMPACT FOR HUMAN MEDICINE Because the method described here induced presinusoidal portal hypertension, these results can be applied to idiopathic portal hypertension in humans.

  19. Design simplicity influences patient portal use: the role of aesthetic evaluations for technology acceptance.

    Science.gov (United States)

    Lazard, Allison J; Watkins, Ivan; Mackert, Michael S; Xie, Bo; Stephens, Keri K; Shalev, Heidi

    2016-04-01

    This study focused on patient portal use and investigated whether aesthetic evaluations of patient portals function are antecedent variables to variables in the Technology Acceptance Model. A cross-sectional survey of current patient portals users (N = 333) was conducted online. Participants completed the Visual Aesthetics of Website Inventory, along with items measuring perceived ease of use (PEU), perceived usefulness (PU), and behavioral intentions (BIs) to use the patient portal. The hypothesized model accounted for 29% of the variance in BIs to use the portal, 46% of the variance in the PU of the portal, and 29% of the variance in the portal's PEU. Additionally, one dimension of the aesthetic evaluations functions as a predictor in the model - simplicity evaluations had a significant positive effect on PEU. This study provides evidence that aesthetic evaluations - specifically regarding simplicity - function as a significant antecedent variable to patients' use of patient portals and should influence patient portal design strategies. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Magnetic Resonance Imaging of a Liver Hydatid Cyst Invading the Portal Vein and Causing Portal Cavernomatosis.

    Science.gov (United States)

    Herek, Duygu; Sungurtekin, Ugur

    2015-01-01

    Hepatic hydatid cysts rarely invade portal veins causing portal cavernomatosis as a secondary complication. We report the case of a patient with direct invasion of the right portal vein by hydatid cysts causing portal cavernomatosis diagnosed via magnetic resonance imaging (MRI). The presented case highlights the useful application of MRI with T2-weighted images and gadolinium-enhanced T1-weighted images in the diagnosis of hepatic hydatid lesions presenting with a rare complication of portal cavernomatosis.

  1. Colangiopatía portal: complicación poco frecuente de la hipertensión portal

    OpenAIRE

    Veloso, Victoria; Servente, Liliana; Hernández, Nelia

    2017-01-01

    Resumen: Se describe el caso clínico de una mujer de 62 años en la que se diagnostica una estenosis del colédoco en el contexto de hipertensión portal prehepática (cavernomatosis portal). Abstract: We report the case of a 62 years old woman with a choledochal stricture and chronic obstruction of the portal vein (portal cavernomatosis). Resumo: Relatamos o caso de uma mulher de 62 anos com diagnóstico de estenose do colédoco no contexto da hipertensão portal pré-hepática (cavernomat...

  2. The XCAT Science Portal

    Directory of Open Access Journals (Sweden)

    Sriram Krishnan

    2002-01-01

    Full Text Available This paper describes the design and prototype implementation of the XCAT Grid Science Portal. The portal lets grid application programmers script complex distributed computations and package these applications with simple interfaces for others to use. Each application is packaged as a notebook which consists of web pages and editable parameterized scripts. The portal is a workstation-based specialized personal web server, capable of executing the application scripts and launching remote grid applications for the user. The portal server can receive event streams published by the application and grid resource information published by Network Weather Service (NWS [35] or Autopilot [16] sensors. Notebooks can be published and stored in web based archives for others to retrieve and modify. The XCAT Grid Science Portal has been tested with various applications, including the distributed simulation of chemical processes in semiconductor manufacturing and collaboratory support for X-ray crystallographers.

  3. Tumoural portal vein thrombosis. Enhancement with MnDPDP

    International Nuclear Information System (INIS)

    Marti-Bonmati, L.; Lonjedo, E.; Mathieu, D.; Coffin, C.; Poyatos, C.; Anglade, M.C.

    1997-01-01

    Purpose: Intrahepatic thrombus is usually associated with either cirrhosis or hepatocellular carcinoma (HCC). Most HCCs enhance after the administration of MnDPDP (Teslascan). Our objective was to analyze the enhancement characteristics of tumour portal vein thrombi. Material and Methods: Thrombi affecting the main or segmental portal veins (17 cases) and the suprahepatic inferior vena cava (1 case) were retrospectively selected from a series of 128 patients studied with MR imaging before and after the administration of MnDPDP. Enhancement was assessed qualitatively and quantitatively. Results: All tumour thrombi enhanced after MnDPDP administration. The enhancement was more conspicuous in the GRE images. On the quantitative evaluation, the portal thrombus enhancement was greater for GRE images than SE images. Portal thrombi enhanced more than the liver and the HCCs. There was a significant difference between the enhancement of the HCCs and the thrombi with both MR imaging techniques. (orig./AJ)

  4. Role of the transjugular intrahepatic portosystemic shunt in the management of severe complications of portal hypertension in idiopathic noncirrhotic portal hypertension.

    Science.gov (United States)

    Bissonnette, Julien; Garcia-Pagán, Juan Carlos; Albillos, Agustín; Turon, Fanny; Ferreira, Carlos; Tellez, Luis; Nault, Jean-Charles; Carbonell, Nicolas; Cervoni, Jean-Paul; Abdel Rehim, Mohamed; Sibert, Annie; Bouchard, Louis; Perreault, Pierre; Trebicka, Jonel; Trottier-Tellier, Félix; Rautou, Pierre-Emmanuel; Valla, Dominique-Charles; Plessier, Aurélie

    2016-07-01

    Idiopathic noncirrhotic portal hypertension is a heterogeneous group of diseases characterized by portal hypertension in the absence of cirrhosis. The efficacy and safety of transjugular intrahepatic portosystemic shunt (TIPS) in this population are unknown. The charts of patients with idiopathic noncirrhotic portal hypertension undergoing TIPS in seven centers between 2000 and 2014 were retrospectively reviewed. Forty-one patients were included. Indications for TIPS were recurrent variceal bleeding (n = 25) and refractory ascites (n = 16). Patients were categorized according to the presence (n = 27) or absence (n = 14) of significant extrahepatic comorbidities. Associated conditions were hematologic, prothrombotic, neoplastic, immune, and exposure to toxins. During follow-up (mean 27 ± 29 months), variceal rebleeding occurred in 7/25 (28%), including three with early thrombosis of the stent. Post-TIPS overt hepatic encephalopathy was present in 14 patients (34%). Eleven patients died, five due the liver disease or complications of the procedure and six because of the associated comorbidities. The procedure was complicated by hemoperitoneum in four patients (10%), which was fatal in one case. Serum creatinine (P = 0.005), ascites as indication for TIPS (P = 0.04), and the presence of significant comorbidities (P = 0.01) at the time of the procedure were associated with death. Mortality was higher in patients with significant comorbidities and creatinine ≥100 μmol/L (P portal hypertension who have normal kidney function or do not have severe extrahepatic conditions, TIPS is an excellent option to treat severe complications of portal hypertension. (Hepatology 2016;64:224-231). © 2016 by the American Association for the Study of Liver Diseases.

  5. Current status of portal vein thrombosis in Japan: Results of a questionnaire survey by the Japan Society for Portal Hypertension.

    Science.gov (United States)

    Kojima, Seiichiro; Watanabe, Norihito; Koizumi, Jun; Kokubu, Shigehiro; Murashima, Naoya; Matsutani, Shoichi; Obara, Katsutoshi

    2018-03-01

    To investigate the current status of portal vein thrombosis (PVT) in Japan, the Clinical Research Committee of the Japan Society of Portal Hypertension undertook a questionnaire survey. A questionnaire survey of 539 cases of PVT over the previous 10 years was carried out at institutions affiliated with the Board of Trustees of the Japan Society of Portal Hypertension. The most frequent underlying etiology of PVT was liver cirrhosis in 75.3% of patients. Other causes included inflammatory diseases of the hepatobiliary system and the pancreas, malignant tumors, and hematologic diseases. The most frequent site was the main trunk of the portal vein (MPV) in 70.5%, and complete obstruction of the MPV was present in 11.5%. Among the medications for PVT, danaparoid was given to 45.8%, warfarin to 26.2%, heparin to 17.3%, and anti-thrombin III to 16.9%. Observation of the course was practiced in 22.4%. Factors contributing to therapeutic efficacy were implementation of various medications, thrombi localized to either the right or left portal vein only, non-complete obstruction of the MPV and Child-Pugh class A liver function. A survival analysis showed that the prognosis was favorable with PVT disappearance regardless of treatment. The questionnaire survey showed the current status of PVT in Japan. Any appropriate medication should be given to a patient with PVT when PVT is recognized. It is necessary to compile a large amount of information and reach a consensus on safe and highly effective management of PVT. © 2017 The Japan Society of Hepatology.

  6. [Role of splenectomy in the treatment of non-cirrhotic portal hypertension: about 3 cases].

    Science.gov (United States)

    Belhamidi, Mohamed Said; Hammi, Salah Eddine; Bouzroud, Mohamed; Benmoussa, Mustapha; Ali, Abdelmounaim Ait; Bounaim, Ahmed

    2017-01-01

    Non-cirrhotic portal hypertension was first described by Guido BANTI in 1898 as a condition characterized by the association of portal hypertension with splenomegaly, anemia and healthy liver. The diagnosis was based on abdominal ultrasound, splenoportography and liver biopsy. Our study aimed to evaluate the role of splenectomy in non-cirrhotic portal hypertension. We conducted a retrospective study of 3 patients (2 women and 1 man) treated by our staff over the period January 2010 -September 2016. The diagnosis of idiopathic portal hypertension was based on the following criteria: portal hypertension, the presence of oesophageal varices associated with splenomegaly, the absence of cirrhosis or of other liver disorders responsible of portal hypertension. All patients underwent splenectomy. Outcome after splenectomy was marked by the standardization of clinical, radiological and biological signs of this disease associated with the absence of oesophageal varices recurrence. Splenectomy associated with ligation of oesophageal varices may be sufficient to treat this syndrome and especially its consequences without using splenorenal bypass.

  7. The NOAO NVO Portal

    Science.gov (United States)

    Miller, C. J.; Gasson, D.; Fuentes, E.

    2007-10-01

    The NOAO NVO Portal is a web application for one-stop discovery, analysis, and access to VO-compliant imaging data and services. The current release allows for GUI-based discovery of nearly a half million images from archives such as the NOAO Science Archive, the Hubble Space Telescope WFPC2 and ACS instruments, XMM-Newton, Chandra, and ESO's INT Wide-Field Survey, among others. The NOAO Portal allows users to view image metadata, footprint wire-frames, FITS image previews, and provides one-click access to science quality imaging data throughout the entire sky via the Firefox web browser (i.e., no applet or code to download). Users can stage images from multiple archives at the NOAO NVO Portal for quick and easy bulk downloads. The NOAO NVO Portal also provides simplified and direct access to VO analysis services, such as the WESIX catalog generation service. We highlight the features of the NOAO NVO Portal (http://nvo.noao.edu).

  8. Hemodynamic evaluation of the right portal vein in healthy dogs of different body weights

    Directory of Open Access Journals (Sweden)

    de Almeida Mariana F

    2010-05-01

    Full Text Available Abstract Background Doppler ultrasonography is an important tool for evaluating hepatic portal hemodynamics. However, no study in dogs of different body weights, in the range encountered in routine clinical veterinary practice, has been reported. It can be difficult to obtain an ideal insonation angle when evaluating the main portal vein, so evaluation of the right portal vein branch has been described in humans as an alternative. The aim of this study was to analyze, through Doppler ultrasonography, the hemodynamics in the right portal vein branch in dogs of different body weights. Methods Thirty normal dogs were divided in three groups by weight, in order to establish normal values for mean velocity, flow volume and portal congestion index of the right portal vein branch by means of Doppler ultrasonography. Results In all dogs ideal insonation angles were obtained for the right portal vein branch. The average velocity was similar in the three groups, but the portal congestion index and the flow volume differed, showing that the weight of the dog can influence these values. Conclusion Doppler ultrasonography for the evaluation of flow in the right branch of the portal vein could be a viable alternative, or complement, to examining the main vessel segment. This is especially so in those animals in which an ideal insonation angle for examination of the main portal vein is hard to obtain. In addition, the weight of the dog must be considered for the correct evaluation of the portal system hemodynamics, particularly for portal blood flow and the congestion index.

  9. Ultrasonographic Measurement of the Diameter of a Normal Bile Duct, Hepatic Artery and Portal Vein in Infants Younger Than 3 Months

    International Nuclear Information System (INIS)

    Kim, Sang Yoon; Lee, Young Seok

    2009-01-01

    This study focused on measuring the diameter of the normal bile duct, hepatic artery and portal vein with high resolution US in infants younger than 3 months, and we wanted to determine the relative ratio of these diameters. Fifty US examinations were performed on infants younger than 3 months and who did not have any clinical or laboratory abnormality associated with the hepatobiliary system. We measured the diameter of the bile duct, hepatic artery and portal vein at the level of the portal vein bifurcation with using 17-5 MHz US and we determined the relative ratios of these diameters. To evaluate the statistical difference in the diameter of the bile duct, hepatic artery and portal vein, we performed one-way ANOVA and Scheffe's multiple comparison test. To determine the relative ratio of these diameters, the ratio of the bile duct to the hepatic artery was defined as the hepatic artery/bile duct, the ratio of the hepatic artery to the portal vein was defined as the portal vein/hepatic artery and the ratio of the bile duct to the portal vein was defined as the portal vein/bile duct. We calculated the averages ± standard deviations of this data (minimum ∼ maximum). In all fifty infants, the bile duct, hepatic artery and portal vein were detectable and measurable. The average diameter of a bile duct was 0.85 ± 0.19 mm (0.56 ∼ 1.47 mm), it was 1.33 ± 0.31 mm (0.90 ∼ 2.37 mm) for the hepatic artery and 3.32 ± 0.68 mm (2.06 ∼ 5.08 mm) for the portal vein. The diameter of these structures was significantly different from each other according to one-way ANOVA (p < 0.001). The average diameter of the hepatic artery was significantly larger than that of the bile duct and the average diameter of the portal vein was significantly larger than that of bile duct and hepatic artery on Scheffe's multiple comparison test. The relative ratio of the bile duct to the hepatic artery was 1.60 ± 0.41 (0.77 ∼ 2.66), that of the hepatic artery to the portal vein was 2

  10. Novel serological neo-epitope markers of extracellular matrix proteins for the detection of portal hypertension.

    Science.gov (United States)

    Leeming, D J; Karsdal, M A; Byrjalsen, I; Bendtsen, F; Trebicka, J; Nielsen, M J; Christiansen, C; Møller, S; Krag, A

    2013-11-01

    The hepatic venous pressure gradient (HVPG) is an invasive, but important diagnostic and prognostic marker in cirrhosis with portal hypertension (PHT). During cirrhosis, remodelling of fibrotic tissue by matrix metalloproteinases (MMPs) is a permanent process generating small fragments of degraded extracellular matrix (ECM) proteins known as neoepitopes, which are then released into the circulation. To investigate their potential as plasma markers for detection of PHT. Ninety-four patients with alcoholic cirrhosis and 20 liver-healthy controls were included. Clinical and laboratory data of the patients were collected. All patients received HVPG measurement with blood sampling. In these samples, the following degradation or formation markers were measured: C1M (type I-collagen), C3M and PRO-C3 (type III collagen), C4M and P4NP 7S (type IV collagen), C5M (type V collagen), C6M (type VI collagen), BGM (biglycan), ELM (elastin), CRPM (CRP). All ECM markers except for CRPM correlated significantly with HVPG. Interestingly, C4M, C5M and ELM levels were significantly higher in patients with HVPG >10 mmHg. Multiple regression analysis identified PRO-C3, C6M and ELM as significant determinants, while the models A and B including PRO-C3, ELM, C6M and model for end-stage liver disease (MELD) provided better description of PHT (r = 0.75, P models provided odds ratios of >100 for having clinical significant PHT. These novel non-invasive extracellular matrix markers reflect the degree of liver dysfunction. The different degrees of portal hypertension correlated with these circulating neoepitopes. Using a single blood sample, these neoepitopes in combination with MELD detect the level of portal hypertension. © 2013 The Authors. Alimentary Pharmacology and Therapeutics published by John Wiley & Sons Ltd.

  11. Tc-99m-Sn colloid dynamic and static scintigraphic evaluation of patients with portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Kamal, S; Lodhi, T; Qureshi, H; Zuberi, S; Khan, R

    1986-04-01

    Dynamic scintigraphy of the liver and spleen was performed by injecting Tc-99m-Sl colloid as a bolus in 15 normal controls and 17 patients presenting with portal hypertension. Using a computer, the hepatic and splenic time-activity curves were analyzed. In addition to the Ratio of Area, the Ratio of Integral and Slope of Integral for liver to spleen were also calculated. The Ratio of the Area (L/S) was significantly different in the normal and portal hypertensives (p < 0.001). The Ratios of the Integral and the slope of the Integral were not only significantly different in the normals and portal hypertensives (p < 0.001) but were also significantly different in the cirrhotic and the non-cirrhotic group of portal hypertensives (p < 0.001). In the routine study of liver scintigraphy in cases of portal hypertension, by adding the above mentioned method, the increased information of uptake dynamics seems to be useful for differentiating the cirrhotic and non-cirrhotic groups of portal hypertension.

  12. Tc-99m-Sn colloid dynamic and static scintigraphic evaluation of patients with portal hypertension

    International Nuclear Information System (INIS)

    Kamal, S.; Lodhi, T.; Qureshi, H.; Zuberi, S.; Khan, R.

    1986-01-01

    Dynamic scintigraphy of the liver and spleen was performed by injecting Tc-99m-Sl colloid as a bolus in 15 normal controls and 17 patients presenting with portal hypertension. Using a computer, the hepatic and splenic time-activity curves were analyzed. In addition to the Ratio of Area, the Ratio of Integral and Slope of Integral for liver to spleen were also calculated. The Ratio of the Area (L/S) was significantly different in the normal and portal hypertensives (p < 0.001). The Ratios of the Integral and the slope of the Integral were not only significantly different in the normals and portal hypertensives (p < 0.001) but were also significantly different in the cirrhotic and the non-cirrhotic group of portal hypertensives (p < 0.001). In the routine study of liver scintigraphy in cases of portal hypertension, by adding the above mentioned method, the increased information of uptake dynamics seems to be useful for differentiating the cirrhotic and non-cirrhotic groups of portal hypertension. (author)

  13. Radionuclide identification algorithm for organic scintillator-based radiation portal monitor

    Energy Technology Data Exchange (ETDEWEB)

    Paff, Marc Gerrit, E-mail: mpaff@umich.edu; Di Fulvio, Angela; Clarke, Shaun D.; Pozzi, Sara A.

    2017-03-21

    We have developed an algorithm for on-the-fly radionuclide identification for radiation portal monitors using organic scintillation detectors. The algorithm was demonstrated on experimental data acquired with our pedestrian portal monitor on moving special nuclear material and industrial sources at a purpose-built radiation portal monitor testing facility. The experimental data also included common medical isotopes. The algorithm takes the power spectral density of the cumulative distribution function of the measured pulse height distributions and matches these to reference spectra using a spectral angle mapper. F-score analysis showed that the new algorithm exhibited significant performance improvements over previously implemented radionuclide identification algorithms for organic scintillators. Reliable on-the-fly radionuclide identification would help portal monitor operators more effectively screen out the hundreds of thousands of nuisance alarms they encounter annually due to recent nuclear-medicine patients and cargo containing naturally occurring radioactive material. Portal monitor operators could instead focus on the rare but potentially high impact incidents of nuclear and radiological material smuggling detection for which portal monitors are intended.

  14. Radionuclide identification algorithm for organic scintillator-based radiation portal monitor

    Science.gov (United States)

    Paff, Marc Gerrit; Di Fulvio, Angela; Clarke, Shaun D.; Pozzi, Sara A.

    2017-03-01

    We have developed an algorithm for on-the-fly radionuclide identification for radiation portal monitors using organic scintillation detectors. The algorithm was demonstrated on experimental data acquired with our pedestrian portal monitor on moving special nuclear material and industrial sources at a purpose-built radiation portal monitor testing facility. The experimental data also included common medical isotopes. The algorithm takes the power spectral density of the cumulative distribution function of the measured pulse height distributions and matches these to reference spectra using a spectral angle mapper. F-score analysis showed that the new algorithm exhibited significant performance improvements over previously implemented radionuclide identification algorithms for organic scintillators. Reliable on-the-fly radionuclide identification would help portal monitor operators more effectively screen out the hundreds of thousands of nuisance alarms they encounter annually due to recent nuclear-medicine patients and cargo containing naturally occurring radioactive material. Portal monitor operators could instead focus on the rare but potentially high impact incidents of nuclear and radiological material smuggling detection for which portal monitors are intended.

  15. Clinical need for both scintigraphy with technetium-99m GSA and per-rectal portal scintigraphy in some patients with chronic liver disease

    Energy Technology Data Exchange (ETDEWEB)

    Shiomi, Susumu; Iwata, Yoshinori; Sasaki, Nobumitsu [Osaka City Univ. (Japan). Medical School] (and others)

    1999-08-01

    Scintigraphy with {sup 99m}Tc-diethylenetriaminepentaacetate with galactosyl human serum albumin ({sup 99m}Tc-GSA) and per-rectal portal scintigraphy are useful for evaluating hepatic functional reserve and portal circulation, respectively. We did the procedures simultaneously in some patients to examine the relationship between hepatic functional reserve and portal circulation in chronic liver disease. Scintigraphy with {sup 99m}Tc-GSA was done in 10 healthy subjects, 45 patients with chronic hepatitis, and 165 patients with cirrhosis. Fifty-seven patients (13 with hepatitis and 44 with cirrhosis) also underwent per-rectal portal scintigraphy with {sup 99m}Tc-pertechnetate within two weeks. A receptor index was calculated by dividing the radioactivity of the liver region of interest (ROI) by that of the liver-plus-heart ROI at 15 min after the injection of {sup 99m}Tc-GSA. The index of blood clearance was calculated by dividing the radioactivity of the heart ROI at 15 min by that of the heart ROI at 3 min. A solution containing {sup 99m}Tc-pertechnetate was instilled into the rectum, and serial scintigrams were taken while radioactivity curves for the liver and heart were recorded sequentially. A per-rectal portal shunt index was determined by calculating the ratio of counts for the liver to counts for the heart integrated for 24 seconds immediately after the appearance of the liver time-activity curve. The median receptor index was lower for more severe liver disorders, increasing in the order of chronic hepatitis, compensated cirrhosis and decompensated cirrhosis, and the median index of blood clearance was higher. The median receptor index was significantly lower when a complication (varices, ascites, or encephalopathy) was present, and the median index of blood clearance was higher. The shunt index was correlated significantly with the two other indices, but these values for some one-third of the patients disagreed in either indices. Scintigraphy with {sup 99m

  16. Isolation and characterization of portal branch ligation-stimulated Hmga2-positive bipotent hepatic progenitor cells

    International Nuclear Information System (INIS)

    Sakai, Hiroshi; Tagawa, Yoh-ichi; Tamai, Miho; Motoyama, Hiroaki; Ogawa, Shinichiro; Soeda, Junpei; Nakata, Takenari; Miyagawa, Shinichi

    2010-01-01

    Research highlights: → Hepatic progenitor cells were isolated from the portal branch-ligated liver of mice. → Portal branch ligation-stimulated hepatic progenitor cells (PBLHCs) express Hmga2. → PBLHCs have bidirectional differentiation capability in vitro. -- Abstract: Hepatic stem/progenitor cells are one of several cell sources that show promise for restoration of liver mass and function. Although hepatic progenitor cells (HPCs), including oval cells, are induced by administration of certain hepatotoxins in experimental animals, such a strategy would be inappropriate in a clinical setting. Here, we investigated the possibility of isolating HPCs in a portal branch-ligated liver model without administration of any chemical agents. A non-parenchymal cell fraction was prepared from the portal branch-ligated or non-ligated lobe, and seeded onto plates coated with laminin. Most of the cells died, but a small number were able to proliferate. These proliferating cells were cloned as portal branch ligation-stimulated hepatic cells (PBLHCs) by the limiting dilution method. The PBLHCs expressed cytokeratin19, albumin, and Hmga2. The PBLHCs exhibited metabolic functions such as detoxification of ammonium ions and synthesis of urea on Matrigel-coated plates in the presence of oncostatin M. In Matrigel mixed with type I collagen, the PBLHCs became rearranged into cystic and tubular structures. Immunohistochemical staining demonstrated the presence of Hmga2-positive cells around the interlobular bile ducts in the portal branch-ligated liver lobes. In conclusion, successful isolation of bipotent hepatic progenitor cell clones, PBLHCs, from the portal branch-ligated liver lobes of mice provides the possibility of future clinical application of portal vein ligation to induce hepatic progenitor cells.

  17. Profile of extrahepatic portal venous obstruction (ehpvo) in a tertiary care hospital in pakistan

    International Nuclear Information System (INIS)

    Shah, S.K.; But, J.A.; Awan, A.

    2007-01-01

    To study the clinical and laboratory profile of patients with EHPVO in a tertiary care hospital of Pakistan and to differentiate EHPVO from cirrhosis of liver and to see the effect on liver function tests. This is a prospective observational study conducted at Department of Gastroenterology, Pakistan Institute of Medical Sciences, Islamabad. Twenty five patients of 12-55 years of age with the features of portal hypertension were included in this study. After careful history and physical examination patients were subjected for laboratory investigations including liver function test, renal function test, blood CP, PT, APTT, HbsAg and anti HCV, other specialized procedures including endoscopy, liver biopsy and ultra sound was also done in all patients. Portal vein thrombosis was the predominant cause of EHPVO, accounting for 88% of cases. All patients were presented with upper GI bleeding, splenomegaly was observed in 88% of patients. None of the patients had clinical, biochemical or liver biopsy evidence of chronic liver disease. The diagnosis of extra hepatic portal venous obstruction and differentiation from cirrhosis can be easily made by characteristic clinical features, normal liver function tests and doppler ultrasound. Portal vein thrombosis (PVT) is the predominant cause of EHPVO in Pakistani patients, as seen at this tertiary care hospital in Pakistan. (author)

  18. Hipertensão portal por esquistossomose mansônica hepatoesplênica: efeito da desconexão ázigo-portal com esplenectomia no diâmetro e na velocidade média de fluxo do sistema portal (estudo ultra-sonográfico com Doppler Hepatosplenic schistosomotic portal hypertension: effect of esophagogastric devascularization with splenectomy on the diameter and mean flow velocity in the portal system (ultra-sonographic Doppler study

    Directory of Open Access Journals (Sweden)

    Azzo WIDMAN

    2001-01-01

    ção significativa do diâmetro e da velocidade média de fluxo sangüíneo no sistema portal, no pós-operatório tardio, em pacientes com esquistossomose mansônica hepatoesplênica, submetidos a desconexão ázigo-portal.Background - Esophagogastric devascularization with splenectomy has been used for the treatment of upper digestive bleeding due to esophagic varices in hepatoportal mansoni's schistosomic portal hypertension. Nevertheless, early portal thrombosis has hampered this surgical technique (13,3% and 53,2%, compromising the good results on the hemorrhagic side. Supposing that portal circulatory changes, due to the surgical treatment, may play an important role in this kind of complication, our objective was to identify the hemodynamic facilitating factors. Portal hemodynamic aspects, identified by ultra-sonographic Doppler study, from two groups of patients: non-operated upon and splenectomized with esophagogastric devascularization in late post-operatory phase (in excess of 6 moths, with portal hypertension due to mansoni hepatoesplenic portal hypertension and in similar clinical conditions, were compared. Method - Fifty eight ambulatorial patients were studied, all had portal hypertension caused by mansoni's hepatosplenic schistosomiasis and previous bouts of digestive bleeding. They were divided in two groups: A - 29 followed clinically/endoscopically, and group B - 29 previously submitted to esophagogastric devascularization with splenectomy. In all was measured the diameter and mean flow velocity in the portal vein and its right and left branches by ultra-sonographic Doppler study. The results were submitted to statistical analysis for inter- and intra-group comparison. Results - Group A (non-operated: the portal vein diameter was greater than the right and left branches (10.6 ± 2.9, 8.0 ± 1.8, 9.1 ± 2.6 cm, the mean flow velocities in the portal vein and its branches were similar (15.62 ± 6.17, 14.92 ± 5.33, 16.12 ±4.18 cm/seg. Group B (operated: the

  19. Evaluation of electrosurgery and titanium clips for ovarian pedicle haemostasis in video-assisted ovariohysterectomy with two portals in bitches

    Directory of Open Access Journals (Sweden)

    Rogério Luizari Guedes

    Full Text Available ABSTRACT: This study evaluated the use of bipolar electrosurgery and laparoscopic clipping, and their effects on blood loss and the inflammatory response, during a two portal video-assisted ovariohysterectomy technique (two groups with 10 animals each. Surgical time and blood loss volume were significantly lower in the electrosurgery group. There were no significant changes in haematocrit between groups; however, haematocrit did differ between evaluated times, and decreased 10% from the initial measurement to four hours after the procedure. The inflammatory response was significantly higher throughout the post-surgical period, but without any different clinical signs between the two groups. Both techniques had good application for the two portal video-assisted procedure; however, the bipolar electrosurgery allowed for shorter surgical times, reduced blood loss and a minimal learning curve for the surgeon.

  20. The Impact of an eHealth Portal on Health Care Professionals' Interaction with Patients: Qualitative Study.

    Science.gov (United States)

    Das, Anita; Faxvaag, Arild; Svanæs, Dag

    2015-11-24

    People who undergo weight loss surgery require a comprehensive treatment program to achieve successful outcomes. eHealth solutions, such as secure online portals, create new opportunities for improved health care delivery and care, but depend on the organizational delivery systems and on the health care professionals providing it. So far, these have received limited attention and the overall adoption of eHealth solutions remains low. In this study, a secure eHealth portal was implemented in a bariatric surgery clinic and offered to their patients. During the study period of 6 months, 60 patients and 5 health care professionals had access. The portal included patient information, self-management tools, and communication features for online dialog with peers and health care providers at the bariatric surgery clinic. The aim of this study was to characterize and assess the impact of an eHealth portal on health care professionals' interaction with patients in bariatric surgery. This qualitative case study involved a field study consisting of contextual interviews at the clinic involving observing and speaking with personnel in their actual work environment. Semi-structured in-depth interviews were conducted with health care professionals who interacted with patients through the portal. Analysis of the collected material was done inductively using thematic analysis. The analysis revealed two main dimensions of using an eHealth portal in bariatric surgery: the transparency it represents and the responsibility that follows by providing it. The professionals reported the eHealth portal as (1) a source of information, (2) a gateway to approach and facilitate the patients, (3) a medium for irrevocable postings, (4) a channel that exposes responsibility and competence, and (5) a tool in the clinic. By providing an eHealth portal to patients in a bariatric surgery program, health care professionals can observe patients' writings and revelations thereby capturing patient

  1. Personalization Methods for Internet Portals

    OpenAIRE

    Barbara Dębska; Agnieszka Kubacka

    2012-01-01

    The article presents methods of acquiring and gathering data about users of internet portals, with particular emphasis on educational portals. Definitions, aims and tasks related to the process of personalization of e-learning portals are thoroughly discussed. So are knowledge acquisition techniques applied in personalization, especially artificial intelligence methods.

  2. Estimation of portal-systemic shunting by rectal infusion of radiotracer

    International Nuclear Information System (INIS)

    Piga, M.; Satta, L.; Loviselli, A.; Taglieri, G.; Balestrieri, A.; Cossu, L.; Madeddu, G.

    1986-01-01

    Spontaneous portal anastomoses develop as a consequence of an increased portal pressure gradient. This report presents a new method for evaluating portal-systemic shunts by rectal infusion of a radiotracer. Five patients affected by primary haemorrhoidal syndrome, 15 with chronic liver disease (CLD), 40 with liver cirrhosis (C), 4 with surgical portal anastomoses (PCA) and 9 healty controls were studied. All patients underwent oesophagogastroscopy and 12 wedged hepatic vein pressure determination. After rectal infusion of 99m TcO 4 - by a microclister, scintigraphic images were recorded at the acquisition rate of 1 per 20 seconds for 10 minutes. Two regions of interest, corresponding to the heart (H) and the liver (L), were traced on the display images and the H/L activity ratio a the 4th minute was determined. In controls, the mean H/L ratio was 0.61±0.09, in CLD 0.76±0.18, in C 1.79±0.31 and in PCA 2.00±0.14. Differences between control H/L ratios and those of the groups of patients were statistically significant (p<0.025, 0.0005 and 0.005, respectively). Significant correlations between H/L ratio and wedged hepatic vein pressure (r=-0.61; p<0.001) were found. This rapid, noninvasive procedure, well tolerated by patients, seems to be suitable for the evaluation of portal haemodynamics and for the prediction of portal pressure values

  3. Collateral hepatic circulation with the portal hypertension syndrome in children

    International Nuclear Information System (INIS)

    Filippkin, M.A.; Kondakov, V.T.; Artamonov, Yu.A.

    1990-01-01

    The results of complex examination carried out in 80 children of different age with the extrahepatic form of portal hypertension and liver fibrosis are presented. Correspondence between clinical and roentgenoangiograph patterns of disease is detected. Dependence of the degree of varicose transformation of submucous veins of the esophagus and stomach on the value and the character of portal blood disposal is established. The risk group is detected. Clinico-X-ray comparisons carried out testify about advisability of the account of individual features of collateral hepatic circulation of the liver when developing medical treatment

  4. Sonographic detection of portal venous gas

    International Nuclear Information System (INIS)

    Lee, Wang Yul; Lee, S. K.; Cho, O. K.

    1989-01-01

    Portal venous gas suggests underlying bowel disease such as strangulating intestinal obstruction and its demonstration carries with it an important implications with respect to patient management. Radiography has been the gold standard for the detection of portal venous gas. We have experienced two cases of portal venous gas diagnosed by ultrasound. Sonographic findings were floating echoes in the main portal vein and highly echogenic linear or patchy echoes within the hepatic parenchyma. Simple abdominal films of those cases failed to demonstrate gas in the portal venous system

  5. Usability of Discovery Portals

    OpenAIRE

    Bulens, J.D.; Vullings, L.A.E.; Houtkamp, J.M.; Vanmeulebrouk, B.

    2013-01-01

    As INSPIRE progresses to be implemented in the EU, many new discovery portals are built to facilitate finding spatial data. Currently the structure of the discovery portals is determined by the way spatial data experts like to work. However, we argue that the main target group for discovery portals are not spatial data experts but professionals with limited spatial knowledge, and a focus outside the spatial domain. An exploratory usability experiment was carried out in which three discovery p...

  6. Doppler waveform study as indicator of change of portal pressure after administration of octreotide

    Science.gov (United States)

    Haider, Shahbaz; Hussain, Qurban; Tabassum, Sumera; Hussain, Bilal; Durrani, Muhammad Rasheed; Ahmed, Fayyaz

    2016-01-01

    Objective: To estimate the effect of portal pressure lowering drug ‘octreotide’, by observing the Doppler waveform before and after the administration of intravenous bolus of octreotide and thus to assess indirectly its efficacy to lower the portal pressure. Methods: This quassi experimental study was carried out in Medical Department in collaboration with Radiology Department of Jinnah Postgraduate Medical Center Karachi Pakistan from September 10, 2015 to February 5, 2016. Cases were selected from patients admitted in Medical Wards and those attending Medical OPD. Diagnosis of cirrhosis was confirmed by Clinical Examination and Lab & Imaging investigation in Medical Department. Doppler waveform study was done by experienced radiologist in Radiology Department before and after administration of octreotide. Doppler signals were obtained from the right hepatic vein. Waveform tracings were recorded for five seconds and categorized as ‘monophasic’, ‘biphasic’ and ‘triphasic’. Waveform changes from one waveform to other were noted and analyzed. Results: Significant change i.e. from ‘monophasic’ to ‘biphasic’ or ‘biphasic’ to ‘triphasic’ was seen in 56% cases while ‘monophasic’ to ‘triphasic’ was seen in 20% cases. No change was seen in 24% cases. Improvement in waveform reflects lowering of portal vein pressure. Conclusion: Non invasive Hepatic vein Doppler waveform study showed improvement in Doppler waveform after administration of octreotide in 76% cases. Doppler waveform study has the potential of becoming non invasive ‘follow up tool’ of choice for assessing portal pressure in patients having variceal bleed due to portal hypertension. PMID:27648043

  7. [Portal thrombosis, common bile duct varices and cholestasis].

    Science.gov (United States)

    Agüera Arroyo, B; Pérez Durán, M A; Montero Alvarez, J L; Navarro Jarabo, J M; Calero Ayala, B; Miño Fugarolas, G

    1996-03-01

    A case of cholestasis in a young patient with portal cavernomatosis is reported. This clinical picture is very infrequent and appears as a consequence of extrinsic compression on the common bile duct due to which the derivative venous collaterals. There does not appear to be any relationship between the intensity of the morphologic alteration of the biliary tract and the level of portal hypertension and the degree of extrahepatic obstruction. Diagnosis was fundamentally achieved by arteriography and retrograde cholangiography with differential diagnosis with the previously mentioned diseases being required. Chronic cholestasis advises derivative surgery in which difficulties may be found due to the presence of thick collaterals in the hepatic pedicle as occurred in this patient.

  8. Percutaneous transhepatic portal vein stenting in a patient with benign non-transplant postoperative portal vein stenosis: A case report

    OpenAIRE

    Madhusudhan, KS; Agrawal, Nikhil; Srivastava, Deep N; Pal, Sujoy; Gupta, Arun K

    2013-01-01

    Extrahepatic portal vein stenosis is caused by a variety of benign and malignant diseases and results in development of symptoms due to portal hypertension. Benign post-surgical adhesions causing portal vein stenosis in non-transplant population is an uncommon etiology of portal hypertension. Endovascular treatment of such patients with angioplasty and stenting is uncommonly reported in literature. We report a case of portal hypertension caused by benign postoperative portal vein fibrosis, su...

  9. Strategi Branding Portal Online Www.tripriau.com Dalam Membangun Brand Awareness Sebagai Portal Online Pariwisata Provinsi Riau

    OpenAIRE

    Rahmadhani, Yuri; Lubis, Evawani Elysa

    2017-01-01

    Online portal www.tripriau.com online portal is one of the online portal in Riau Province that has its own uniqueness. These portals contain local content and the potential of tourism in the province of Riau. Since its establishment, www.tripriau.com do branding strategy in order to build brand awareness or trust the reader to be known as a tourism-themed online portal. As the selection of brand name Trip Riau, Riau Guide My tagline, as well as the implementation of travel instagram photo con...

  10. The Sydney West Knowledge Portal: Evaluating the Growth of a Knowledge Portal to Support Translational Research.

    Science.gov (United States)

    Janssen, Anna; Robinson, Tracy Elizabeth; Provan, Pamela; Shaw, Tim

    2016-06-29

    The Sydney West Translational Cancer Research Centre is an organization funded to build capacity for translational research in cancer. Translational research is essential for ensuring the integration of best available evidence into practice and for improving patient outcomes. However, there is a low level of awareness regarding what it is and how to conduct it optimally. One solution to addressing this gap is the design and deployment of web-based knowledge portals to disseminate new knowledge and engage with and connect dispersed networks of researchers. A knowledge portal is an web-based platform for increasing knowledge dissemination and management in a specialized area. To measure the design and growth of an web-based knowledge portal for increasing individual awareness of translational research and to build organizational capacity for the delivery of translational research projects in cancer. An adaptive methodology was used to capture the design and growth of an web-based knowledge portal in cancer. This involved stakeholder consultations to inform initial design of the portal. Once the portal was live, site analytics were reviewed to evaluate member usage of the portal and to measure growth in membership. Knowledge portal membership grew consistently for the first 18 months after deployment, before leveling out. Analysis of site metrics revealed members were most likely to visit portal pages with community-generated content, particularly pages with a focus on translational research. This was closely followed by pages that disseminated educational material about translational research. Preliminary data from this study suggest that knowledge portals may be beneficial tools for translating new evidence and fostering an environment of communication and collaboration.

  11. The cumulative verification image analysis tool for offline evaluation of portal images

    International Nuclear Information System (INIS)

    Wong, John; Yan Di; Michalski, Jeff; Graham, Mary; Halverson, Karen; Harms, William; Purdy, James

    1995-01-01

    Purpose: Daily portal images acquired using electronic portal imaging devices contain important information about the setup variation of the individual patient. The data can be used to evaluate the treatment and to derive correction for the individual patient. The large volume of images also require software tools for efficient analysis. This article describes the approach of cumulative verification image analysis (CVIA) specifically designed as an offline tool to extract quantitative information from daily portal images. Methods and Materials: The user interface, image and graphics display, and algorithms of the CVIA tool have been implemented in ANSCI C using the X Window graphics standards. The tool consists of three major components: (a) definition of treatment geometry and anatomical information; (b) registration of portal images with a reference image to determine setup variation; and (c) quantitative analysis of all setup variation measurements. The CVIA tool is not automated. User interaction is required and preferred. Successful alignment of anatomies on portal images at present remains mostly dependent on clinical judgment. Predefined templates of block shapes and anatomies are used for image registration to enhance efficiency, taking advantage of the fact that much of the tool's operation is repeated in the analysis of daily portal images. Results: The CVIA tool is portable and has been implemented on workstations with different operating systems. Analysis of 20 sequential daily portal images can be completed in less than 1 h. The temporal information is used to characterize setup variation in terms of its systematic, random and time-dependent components. The cumulative information is used to derive block overlap isofrequency distributions (BOIDs), which quantify the effective coverage of the prescribed treatment area throughout the course of treatment. Finally, a set of software utilities is available to facilitate feedback of the information for

  12. Portal verification for breast cancer radiotherapy

    International Nuclear Information System (INIS)

    Petkovska, Sonja; Pejkovikj, Sasho; Apostolovski, Nebojsha

    2013-01-01

    At the University Clinic in Skopje, breast cancer irradiation is being planned and performed by using a mono-iso centrical method, which means that a unique isocenter (I C) for all irradiation fields is used. The goal of this paper is to present the patient’s position in all coordinates before the first treatment session, relative to the position determined during the CT simulation. Deviation of up to 5 mm is allowed. The analysis was made by using a portal verification. Sixty female patients at random selection are reviewed. The matching results show that for each patient deviation exists at least on one axis. The largest deviations are in the longitudinal direction (head-feet) up to 4 mm, mean 1.8 mm. In 60 out of 85 analysed fields, the deviation is towards the head. In lateral direction, median deviation is 1.1 mm and in 65% of the analysed portals those deviations are in medial direction – contralateral breast which can increases the dose in the lung and in the contralateral breast. This deviation for supraclavicular field can increase the dose in the spinal cord. Although these doses are well below the limit, this fact should be taken into account in setting the treatment fields. The final conclusion from the research is that despite of the fact we are dealing with small deviations, in conditions when accuracy in positioning is done with portal, the portal verification needs to be done in the coming weeks of the treatment, not only before the first treatment. This provides information for an intra fractional set-up deviation. (Author)

  13. Verifying 4D gated radiotherapy using time-integrated electronic portal imaging: a phantom and clinical study

    Directory of Open Access Journals (Sweden)

    Slotman Ben J

    2007-08-01

    Full Text Available Abstract Background Respiration-gated radiotherapy (RGRT can decrease treatment toxicity by allowing for smaller treatment volumes for mobile tumors. RGRT is commonly performed using external surrogates of tumor motion. We describe the use of time-integrated electronic portal imaging (TI-EPI to verify the position of internal structures during RGRT delivery Methods TI-EPI portals were generated by continuously collecting exit dose data (aSi500 EPID, Portal vision, Varian Medical Systems when a respiratory motion phantom was irradiated during expiration, inspiration and free breathing phases. RGRT was delivered using the Varian RPM system, and grey value profile plots over a fixed trajectory were used to study object positions. Time-related positional information was derived by subtracting grey values from TI-EPI portals sharing the pixel matrix. TI-EPI portals were also collected in 2 patients undergoing RPM-triggered RGRT for a lung and hepatic tumor (with fiducial markers, and corresponding planning 4-dimensional CT (4DCT scans were analyzed for motion amplitude. Results Integral grey values of phantom TI-EPI portals correlated well with mean object position in all respiratory phases. Cranio-caudal motion of internal structures ranged from 17.5–20.0 mm on planning 4DCT scans. TI-EPI of bronchial images reproduced with a mean value of 5.3 mm (1 SD 3.0 mm located cranial to planned position. Mean hepatic fiducial markers reproduced with 3.2 mm (SD 2.2 mm caudal to planned position. After bony alignment to exclude set-up errors, mean displacement in the two structures was 2.8 mm and 1.4 mm, respectively, and corresponding reproducibility in anatomy improved to 1.6 mm (1 SD. Conclusion TI-EPI appears to be a promising method for verifying delivery of RGRT. The RPM system was a good indirect surrogate of internal anatomy, but use of TI-EPI allowed for a direct link between anatomy and breathing patterns.

  14. Portal pressure correlated to visceral circulation times

    Energy Technology Data Exchange (ETDEWEB)

    Friman, L [Serafimerlasarettet, Stockholm (Sweden)

    1979-01-01

    Visceral angiography was performed in 7 patients with normal portal pressure and in 10 with portal hypertension. Circulation times, size of vessels and portal pressure were determined. At celiac angiography, a direct correlation was found between time for maximum filling of portal vein and portal pressure, provided no vascular abnormalities existed. At superior mesenteric angiography such a correlation was not found; loss of flow by shunts in portal hypertension being one explanation. Portocaval shunts are common in the celiac system, but uncommon in the superior mesenteric system.

  15. Percutaneous transhepatic portal vein stenting in a patient with benign non-transplant postoperative portal vein stenosis: A case report

    Directory of Open Access Journals (Sweden)

    KS Madhusudhan

    2013-01-01

    Full Text Available Extrahepatic portal vein stenosis is caused by a variety of benign and malignant diseases and results in development of symptoms due to portal hypertension. Benign post-surgical adhesions causing portal vein stenosis in non-transplant population is an uncommon etiology of portal hypertension. Endovascular treatment of such patients with angioplasty and stenting is uncommonly reported in literature. We report a case of portal hypertension caused by benign postoperative portal vein fibrosis, successfully treated by self-expandable metallic stent.

  16. Influence of Dai-kenchu-to (DKT) on human portal blood flow.

    Science.gov (United States)

    Ogasawara, Takashi; Morine, Yuji; Ikemoto, Tetsuya; Imura, Satoru; Fujii, Masahiko; Soejima, Yuji; Shimada, Mitsuo

    2008-01-01

    Dai-kenchu-to (DKT) is known as an herbal medicine used for postoperative ileus. However, no report exists about the effect of DKT on portal blood flow. The aim of this study is to clarify the influence of DKT on portal blood flow. To healthy volunteers (Healthy; n = 6), cirrhotic patients (Cirrhosis; n = 7) and liver-transplant patients (LTx; n = 3), DKT (2.5g) with 100mL of warm water was orally administrated in the DKT group, and only warm water was administrated in the control group. The portal blood flow rate (M-VEL: cm/sec.) and portal blood flow (Flow volume: mL/min.) was measured each time after administration using an ultrasonic Doppler method. Furthermore, the arterial blood pressure and heart rate was measured at the same time points. In the DKT group, a significant increase of M-VEL (120%) and flow volume (150%) 30 minutes after administration was observed in both Healthy and Cirrhosis in comparison with the control group. In LTx, there was also a significant increase of flow volume (128%) 30 minutes after administration. However, there was no change in average blood pressure and heart rate in all groups. DKT increases portal blood flow in early phase after oral administration without any significant changes in the blood pressure and heart rate.

  17. Positive identity entry control system with geographically distributed portals and enrollment stations

    International Nuclear Information System (INIS)

    McIntire, J.M.

    1985-01-01

    A positive identity entry control system using distributed processing to allow reliable geographically separated portals and enrollment stations has been installed and is fully operational at a large area DOE site. Identity verification requires a credential, a memorized number and measurement of a physical characteristic of the user. Additionally, all portal activity is monitored by guards. The portal system is dual redundant such that no single point failure will shut down operations. Each portal site maintains its own subset of the master data base so off-site failure of the central data base manager or its communication links will not significantly affect local portal activity. The system is suitable for installations with large populations requiring access control at several remote sites scattered over a large area

  18. Splenectomy Causes 10-Fold Increased Risk of Portal Venous System Thrombosis in Liver Cirrhosis Patients.

    Science.gov (United States)

    Qi, Xingshun; Han, Guohong; Ye, Chun; Zhang, Yongguo; Dai, Junna; Peng, Ying; Deng, Han; Li, Jing; Hou, Feifei; Ning, Zheng; Zhao, Jiancheng; Zhang, Xintong; Wang, Ran; Guo, Xiaozhong

    2016-07-19

    BACKGROUND Portal venous system thrombosis (PVST) is a life-threatening complication of liver cirrhosis. We conducted a retrospective study to comprehensively analyze the prevalence and risk factors of PVST in liver cirrhosis. MATERIAL AND METHODS All cirrhotic patients without malignancy admitted between June 2012 and December 2013 were eligible if they underwent contrast-enhanced CT or MRI scans. Independent predictors of PVST in liver cirrhosis were calculated in multivariate analyses. Subgroup analyses were performed according to the severity of PVST (any PVST, main portal vein [MPV] thrombosis >50%, and clinically significant PVST) and splenectomy. Odds ratios (ORs) and 95% confidence intervals (CIs) were reported. RESULTS Overall, 113 cirrhotic patients were enrolled. The prevalence of PVST was 16.8% (19/113). Splenectomy (any PVST: OR=11.494, 95%CI=2.152-61.395; MPV thrombosis >50%: OR=29.987, 95%CI=3.247-276.949; clinically significant PVST: OR=40.415, 95%CI=3.895-419.295) and higher hemoglobin (any PVST: OR=0.974, 95%CI=0.953-0.996; MPV thrombosis >50%: OR=0.936, 95%CI=0.895-0.980; clinically significant PVST: OR=0.935, 95%CI=0.891-0.982) were the independent predictors of PVST. The prevalence of PVST was 13.3% (14/105) after excluding splenectomy. Higher hemoglobin was the only independent predictor of MPV thrombosis >50% (OR=0.952, 95%CI=0.909-0.997). No independent predictors of any PVST or clinically significant PVST were identified in multivariate analyses. Additionally, PVST patients who underwent splenectomy had a significantly higher proportion of clinically significant PVST but lower MELD score than those who did not undergo splenectomy. In all analyses, the in-hospital mortality was not significantly different between cirrhotic patient with and without PVST. CONCLUSIONS Splenectomy may increase by at least 10-fold the risk of PVST in liver cirrhosis independent of severity of liver dysfunction.

  19. Comparative analysis of pulsed doppler ultrasonography of portal vein vs indirect photography

    International Nuclear Information System (INIS)

    Chang, Jae Chun; Kwon, Huck Po; Hwang, Mi Soo; Kim, Sun Youn; Park, Bok Hwan; Lee, Hyun Ju; Kim, Hong Jin

    1990-01-01

    There are some limitation of interpretation in indirect photography via superior mesenteric artery. In order to supplement and predict indirect photography, we compared indirect photographic findings with pulsed doppler flowmetry in 38 hepatobiliary patients, and the results were as follow: 1. In case of normal main portal vein(MPV) filling, Pulsed Doppler always showed antegrade, continuous parabolic wave form and cases of abnormal MPV filling, showed unusual wave form and flow direction. 2. In normal filling case of proximal right portal vein, Pulsed Doppler almost showed normal continuous parabolic wave form but in normal filling cases of proximal left portal vein, occasionally showed undulating wave form. 3. In each side proximal portal vein abnormal filling case, we could observe abnormal doppler wave form and could obtain additional information using doppler wave form. 4. Mean portal flow velocity was significantly increased in higher photography grade(p=0.01) and congestion index was significantly decreased in higher photography grade(p=0.01). 5. We concluded that doppler ultrasonography could supplement incomplete indirect photography

  20. Portal pressure correlated to visceral circulation times

    International Nuclear Information System (INIS)

    Friman, L.

    1979-01-01

    Visceral angiography was performed in 7 patients with normal portal pressure and in 10 with portal hypertension. Circulation times, size of vessels and portal pressure were determined. At celiac angiography, a direct correlation was found between time for maximum filling of portal vein and portal pressure, provided no vascular abnormalities existed. At superior mesenteric angiography such a correlation was not found; loss of flow by shunts in portal hypertension being one explanation. Portocaval shunts are common in the celiac system, but uncommon in the superior mesenteric system. (Auth.)

  1. Development of a computerized portal verification scheme for pelvic treatment fields

    International Nuclear Information System (INIS)

    Nie, K.; Yin, F.-F.; Gao, Q.; Brasacchio, R.

    1996-01-01

    Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV camera into images with 256 x 256 matrix and 8 bit gray levels. Initially a Canny edge detector is applied to identify the field edges and an elliptic Fourier transformation is used to correlate the size and shape information between the reference and portal field edges. Several measures can be calculated using the transformation coefficients to describe the field shape, size and orientation. The quantitative information regarding to the relative shifts, rotation and magnification factor between portal and reference field edges can then be determined based on these measures. Next the pelvic brim, which is typically used as the landmark for radiation treatment verification, is identified by a pyramid searching process with double snakes defined from initial global area to final local area. A snake is an active model and energy-minimizing spline guided by external constraint forces and influenced by image forces that pull it toward features such as lines and edges. The search range is limited to the region between two snakes. Sobel edge detector and wavelet transformation approach are used to generate a serial image forces at

  2. Role of hydrogen sulfide in portal hypertension and esophagogastric junction vascular disease

    Science.gov (United States)

    Wang, Chao; Han, Juan; Xiao, Liang; Jin, Chang-E; Li, Dong-Jian; Yang, Zhen

    2014-01-01

    AIM: To investigate the association between endogenous hydrogen sulfide (H2S) and portal hypertension as well as its effect on vascular smooth muscle cells. METHODS: Portal hypertension patients were categorized by Child-Pugh score based on bilirubin and albumin levels, prothrombin time, ascites and hepatic encephalopathy. Plasma H2S concentrations and portal vein diameters (PVDs) were compared between portal hypertension patients and control participants, as well as between portal hypertension patients with varying degrees of severity. In addition, we established a rabbit hepatic schistosomiasis portal hypertension (SPH) model and analyzed liver morphology, fibrosis grade, plasma and liver tissue H2S concentrations, as well as cystathionine γ-lyase (CSE) activity and phosphorylated extracellular signal-regulated kinase (pERK)1/2, B cell lymphoma (Bcl)-2 and Bcl-XL expression in portal vein smooth muscle cells, in addition to their H2S-induced apoptosis rates. RESULTS: In portal hypertension patients, endogenous H2S levels were significantly lower than those in healthy controls. The more severe the disease was, the lower were the H2S plasma levels, which were inversely correlated with PVD and Child-Pugh score. Liver tissue H2S concentrations and CSE expression were significantly lower in the SPH rabbit livers compared with the control animals, starting at 3 wk, whereas pERK 1/2 expressions gradually increased 12-20 wk after SPH model establishment. In portal vein smooth muscle cells, increasing H2S levels led to increased apoptosis, while Bcl-2 and Bcl-XL expression decreased. CONCLUSION: H2S prevents vascular restructuring caused by excessive proliferation of smooth muscle cells via apoptosis induction, which helps to maintain normal vascular structures. PMID:24574782

  3. Increase in Efficiency of Use of Pedestrian Radiation Portal Monitors

    Science.gov (United States)

    Solovev, D. B.; Merkusheva, A. E.

    2017-11-01

    Most international airports in the world use radiation portal monitors (RPM) for primary radiation control organization. During the exploitation pedestrian radiation portal monitors operators (in the Russian Federation it is a special subdivision of customs officials) have certain problems related to the search of an ionizing radiation source causing the alarm signal of a radiation monitor. Radiation portal monitors at standard (factory) settings have to find out the illegal moving of the radioisotopes moved by physical persons passing through a controlled zone and having a steady radiation by the gamma or neutron channel. The problem is that recently the number of the ownerships who underwent treatment or medical diagnostics with the use of radio pharmaceuticals considerably increased, i.e,. ownerships represent such an ionizing radiation source. The operator of the radiation portal monitor has to define very quickly whether the ownership is a violator (takes unsolved radioisotopes illegally) or is just a patient of the clinic who underwent treatment/diagnostics with the use of radio pharmaceuticals. The research showing the radioisotopes which are most often used in the medical purposes are given in article, it is offered to use the new software developed by the authors allowing the operator of the radiation portal monitor to define the location of the ownership which has such ionizing radiation source by the activity of radiation similar to the radiation from radio pharmaceuticals.

  4. [Invasion of the portal vein by a hydatid cyst. Review of the literature].

    Science.gov (United States)

    Zubiaurre Lizarralde, Leire; Oyarzabal Pérez, Igor; Ruiz Montesinos, Inmaculada; Guisasola Gorrotxategi, Esther

    2006-01-01

    We have found only 3 publications in the literature that describe portal vein invasion by a hydatid cyst. This complication is very uncommon but should be kept in mind in the diagnosis of anaphylactic shock. Clinical presentation can vary from abdominal pain and fever to portal hypertension or anaphylactic reaction due to leaking of antigenic material from the cyst. Ultrasound and computed tomography scan can identify hydatid cysts and cavernomatosis, but magnetic resonance imaging shows the presence of multiple daughter vesicles replacing the lumen of the portal vein and a communication between the residual cyst and the portal vein. The treatment of choice is surgery, including removal of the cyst and local instillation of scolicide solution. In addition to surgery, administration of albendazole is recommended. Administration should begin 4 days before extirpation and should be continued for more than 4 weeks.

  5. Use of an electronic patient portal among the chronically ill: an observational study.

    Science.gov (United States)

    Riippa, Iiris; Linna, Miika; Rönkkö, Ilona; Kröger, Virpi

    2014-12-08

    Electronic patient portals may enhance effective interaction between the patient and the health care provider. To grasp the full potential of patient portals, health care providers need more knowledge on which patient groups prefer electronic services and how patients should be served through this channel. The objective of this study was to assess how chronically ill patients' state of health, comorbidities, and previous care are associated with their adoption and use of a patient portal. A total of 222 chronically ill patients, who were offered access to a patient portal with their health records and secure messaging with care professionals, were included in the study. Differences in the characteristics of non-users, viewers, and interactive users of the patient portal were analyzed before access to the portal. Patients' age, gender, diagnoses, levels of the relevant physiological measurements, health care contacts, and received physiological measurements were collected from the care provider's electronic health record. In addition, patient-reported health and patient activation were assessed by a survey. Despite the broad range of measures used to indicate the patients' state of health, the portal user groups differed only in their recorded diagnosis for hypertension, which was most common in the non-user group. However, there were significant differences in the amount of care received during the year before access to the portal. The non-user group had more nurse visits and more measurements of relevant physiological outcomes than viewers and interactive users. They also had fewer referrals to specialized care during the year before access to the portal than the two other groups. The viewers and the interactive users differed from each other significantly in the number of nurse calls received, the interactive users having more calls than the viewers. No significant differences in age, gender, or patient activation were detected between the user groups. Previous

  6. Effect of Metoclopramide on Portal Blood Flow in Patients with Liver Cirrhosis: Evaluation by the Pulsed Doppler System

    International Nuclear Information System (INIS)

    Baik, Soon Koo; Lee, Yong Gyu; Hong, Sa Joon; Lee, Seong Wu; Lee, Dong Ki; Kwong, Sang Ok

    1994-01-01

    Metoclopramide is known to lower the intravariceal flow by raising the lower esophageal sphincter pressure and consequently decreases the portal blood flow. So we designed this study to assess the effect of metoclopramide on portal blood flow in cirrhotic patients using pulsed Doppler system. By using pulsed Doppler ultrasound, portal blood velocity, diameter of the portal vein, portal blood flow, blood pressure and pulse rate were measured at 15, 30 and 60 minutes after administration of 20mg metoclopramide in 16cirrhotic patients and compared with the basal values. In order 10 cirrhotic patients, normal saline was administrated, and the above mentioned parameters were measured. Wothin 15 minutes after intravenous administration of 20mg metoclopramide, portal blood velocity and portal blood flow decreased significantly, from 12.45+2.64 to 11.80+2.55cm/sec and from 1006.3+407.1 to 974.4+414.7ml/min, respectively(P<0.05). In placebo group,there was no significant change in measured parameters after administration of normal saline. These results support the hypothesis that metoclopramide significantly decreases the portal blood flow transiently in cirrhotic patients with portal hypertension

  7. Prolonged Q-T(c) interval in mild portal hypertensive cirrhosis

    DEFF Research Database (Denmark)

    Ytting, Henriette; Henriksen, Jens Henrik; Fuglsang, Stefan

    2005-01-01

    BACKGROUND/AIMS: The Q-T(c) interval is prolonged in a substantial fraction of patients with cirrhosis, thus indicating delayed repolarisation. However, no information is available in mild portal hypertensive patients. We therefore determined the Q-T(c) interval in cirrhotic patients with hepatic...... venous pressure gradient (HVPG) portal hypertension (HVPG> or = 12 mmHg) and controls without liver disease. RESULTS......), values which are significantly above that of the controls (0.410 s(1/2), P portal hypertensive group, the Q-T(c) interval was inversely related to indicators of liver function, such as indocyanine green clearance (r = -0.34, P

  8. A chess web portal

    OpenAIRE

    Volf, Žiga

    2011-01-01

    The aim of the thesis was to develop a web portal for chess players, which is intended to be a place for quality chess joining over the Internet and chess education. This need is caused by existing social networks and websites for playing chess, which offer you a very small amount of quality chess joining and education. As a result of the work the chess portal was created. We have presented the development of the chess portal in the thesis, which has all the features the chess players are i...

  9. BSD Portals for LINUX 2.0

    Science.gov (United States)

    McNab, A. David; woo, Alex (Technical Monitor)

    1999-01-01

    Portals, an experimental feature of 4.4BSD, extend the file system name space by exporting certain open () requests to a user-space daemon. A portal daemon is mounted into the file name space as if it were a standard file system. When the kernel resolves a pathname and encounters a portal mount point, the remainder of the path is passed to the portal daemon. Depending on the portal "pathname" and the daemon's configuration, some type of open (2) is performed. The resulting file descriptor is passed back to the kernel which eventually returns it to the user, to whom it appears that a "normal" open has occurred. A proxy portalfs file system is responsible for kernel interaction with the daemon. The overall effect is that the portal daemon performs an open (2) on behalf of the kernel, possibly hiding substantial complexity from the calling process. One particularly useful application is implementing a connection service that allows simple scripts to open network sockets. This paper describes the implementation of portals for LINUX 2.0.

  10. Portal monitoring technology control process

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    Portal monitors are an important part of the material protection, control, and accounting (MPC and A) programs in Russia and the US. Although portal monitors are only a part of an integrated MPC and A system, they are an effective means of controlling the unauthorized movement of special nuclear material (SNM). Russian technical experts have gained experience in the use of SNM portal monitors from US experts ad this has allowed them to use the monitors more effectively. Several Russian institutes and companies are designing and manufacturing SNM portal monitors in Russia. Interactions between Russian and US experts have resulted in improvements to the instruments. SNM portal monitor technology has been effectively transferred from the US to Russia and should be a permanent part of the Russian MPC and A Program. Progress in the implementation of the monitors and improvements to how they are used are discussed

  11. An interactive E-Learning Portal in Pediatric Endocrinology: Practical Experience

    Directory of Open Access Journals (Sweden)

    Stenvert L. S. Drop

    2013-10-01

    Full Text Available Based on educational considerations, the European Society for Paediatric Endocrinology (ESPE e-learning portal has been developed, providing an interactive learning environment for up-to-date information in pediatric endocrinology. From March 2011 to January 2012, five small-scale pilot studies were completed to assess the usefulness of the structure and content by senior experts, fellows, residents and medical students. Altogether, 8 cases and 4 chapters were studied by a total of 71 individuals: 18 senior experts, 21 fellows, 10 medical students, 9 regional pediatricians and 13 residents, resulting in a total of 127 evaluations. Participants considered the portal content interesting and appreciated the way of learning compared to traditional learning from literature and textbooks. Special attention was paid to assess the personalized feedback given by experts to fellows and residents who completed the portal. Feedback from experts included both medical understanding and communication skills demonstrated by fellows and residents. Users highly appreciated the feedback of the medical experts, who brought perspectives from another clinic. This portal also offers educational opportunities for medical students and regional pediatricians and can be used to develop various CanMEDS competencies, e.g., medical expert, health advocate, and scholar.

  12. IMPACT web portal: oncology database integrating molecular profiles with actionable therapeutics.

    Science.gov (United States)

    Hintzsche, Jennifer D; Yoo, Minjae; Kim, Jihye; Amato, Carol M; Robinson, William A; Tan, Aik Choon

    2018-04-20

    With the advancement of next generation sequencing technology, researchers are now able to identify important variants and structural changes in DNA and RNA in cancer patient samples. With this information, we can now correlate specific variants and/or structural changes with actionable therapeutics known to inhibit these variants. We introduce the creation of the IMPACT Web Portal, a new online resource that connects molecular profiles of tumors to approved drugs, investigational therapeutics and pharmacogenetics associated drugs. IMPACT Web Portal contains a total of 776 drugs connected to 1326 target genes and 435 target variants, fusion, and copy number alterations. The online IMPACT Web Portal allows users to search for various genetic alterations and connects them to three levels of actionable therapeutics. The results are categorized into 3 levels: Level 1 contains approved drugs separated into two groups; Level 1A contains approved drugs with variant specific information while Level 1B contains approved drugs with gene level information. Level 2 contains drugs currently in oncology clinical trials. Level 3 provides pharmacogenetic associations between approved drugs and genes. IMPACT Web Portal allows for sequencing data to be linked to actionable therapeutics for translational and drug repurposing research. The IMPACT Web Portal online resource allows users to query genes and variants to approved and investigational drugs. We envision that this resource will be a valuable database for personalized medicine and drug repurposing. IMPACT Web Portal is freely available for non-commercial use at http://tanlab.ucdenver.edu/IMPACT .

  13. Prevalence of gastric varices and portal hypertensive gastropathy in patients with Symmer's periportal fibrosis

    International Nuclear Information System (INIS)

    Mudawi, H.; Ali, Y.; El-Tahir, M.

    2008-01-01

    Symmer's periportal fibrosis secondary to schistosomiasis is a common cause of portal hypertension worldwide. Data on the prevalence of gastric variances and portal hypertensive gastropathy in this group of patients with portal of hypertension is relatively scarce. The aim of this study was to determine the prevalence of gastric varices and portal hypertensive gastropathy in patients presenting with portal hypertension secondary to Symmer's periportal fibrosis. In a prospective study, upper gastrointestinal endoscopy was carried out to determine the prevalence of gastric varices and portal hypertensive gastropathy in patients with portal hypertension secondary to Symmer's fibrosis. Of 143 patients studied, 24 patients (16.8%) had gastric varices (grade I in 10.5%, grade Ii in 6.3%) and 31 patients (21.7%) had portal hypertensive gastropathy (mild in 11.2%, severe in 10.5%). Gastric varices were more prevalent in patients with grade I and II esophageal varices and portal hypertensive gastropathy was more prevalent in those with grade III and IV esophageal varices, but the differences were not statistically significant. We conclude that both gastric varices and portal hypertensive gastropathy seem to have a lower prevalence in patients with portal hypertension secondary to Symmer's periportal fibrosis when compared to reported data in patients with portal hypertension secondary to liver cirrhosis and non-cirrhotic portal fibrosis. (author)

  14. Staged Transcatheter Treatment of Portal Hypoplasia and Congenital Portosystemic Shunts in Children

    Energy Technology Data Exchange (ETDEWEB)

    Bruckheimer, Elchanan, E-mail: elchananb@bezeqint.net; Dagan, Tamir [Schneider Children' s Medical Center Israel, Section of Pediatric Cardiology (Israel); Atar, Eli; Schwartz, Michael [Schneider Children' s Medical Center Israel, Section of Radiology (Israel); Kachko, Ludmila [Schneider Children' s Medical Center Israel, Section of Anesthesiology (Israel); Superina, Riccardo; Amir, Gabriel [Schneider Children' s Medical Center Israel, Section of Pediatric Cardiology (Israel); Shapiro, Rivka [Schneider Children' s Medical Center Israel, Section of Gastroenterology (Israel); Birk, Einat [Schneider Children' s Medical Center Israel, Section of Pediatric Cardiology (Israel)

    2013-12-15

    Purpose: Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Methods: Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by {approx}50 %. Recatheterization was performed approximately 3 months later. If the portal pressure was below 18 mmHg and vessels had developed, the shunt was closed with a device. Results: Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5-13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2-8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 {+-} 11.3 to 10.8 {+-} 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 {+-} 0.5 to 4.0 {+-} 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 {+-} 53.6 to 65.7 {+-} 9.6 {mu}mol/L; p = 0.002) with no complications. Conclusion: Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia.

  15. Outcomes of pregnancies complicated by liver cirrhosis, portal hypertension, or esophageal varices.

    Science.gov (United States)

    Puljic, Anela; Salati, Jennifer; Doss, Amy; Caughey, Aaron B

    2016-01-01

    To evaluate pregnancy outcomes in women with liver cirrhosis, portal hypertension, or esophageal varices. We analyzed a retrospective cohort of 2,284,218 pregnancies in 2005-2009 recorded in the California Birth Registry database. Utilizing ICD-9 codes we analyzed the following outcomes for liver cirrhosis, portal hypertension, or esophageal varices in pregnancy: preeclampsia (PET), preterm delivery (PTD; Portal hypertension in pregnancy was associated with PTD, LBW, NND, and PPH. Non-bleeding esophageal varices in pregnancy were not associated with the outcomes assessed in a statistically significant manner. One case of bleeding esophageal varices was observed, resulting in PTD with a LBW infant. There were three cases of concomitant portal hypertension or concomitant esophageal varices with cirrhosis in pregnancy. Pregnancy in women with concomitant liver cirrhosis, portal hypertension, or esophageal varices can be successful. However, pregnancy outcomes are worse and may warrant closer antenatal monitoring and patient counseling. Cirrhosis in pregnancy with concomitant portal hypertension or esophageal varices is rare.

  16. A heuristic approach to edge detection in on-line portal imaging

    International Nuclear Information System (INIS)

    McGee, Kiaran P.; Schultheiss, Timothy E.; Martin, Eric E.

    1995-01-01

    Purpose: Portal field edge detection is an essential component of several postprocessing techniques used in on-line portal imaging, including field shape verification, selective contrast enhancement, and treatment setup error detection. Currently edge detection of successive fractions in a multifraction portal image series involves the repetitive application of the same algorithm. As the number of changes in the field is small compared to the total number of fractions, standard edge detection algorithms essentially recalculate the same field shape numerous times. A heuristic approach to portal edge detection has been developed that takes advantage of the relatively few changes in the portal field shape throughout a fractionation series. Methods and Materials: The routine applies a standard edge detection routine to calculate an initial field edge and saves the edge information. Subsequent fractions are processed by applying an edge detection operator over a small region about each point of the previously defined contour, to determine any shifts in the field shape in the new image. Failure of this edge check indicates that a significant change in the field edge has occurred, and the original edge detection routine is applied to the image. Otherwise the modified edge contour is used to define the new edge. Results: Two hundred and eighty-one portal images collected from an electronic portal imaging device were processed by the edge detection routine. The algorithm accurately calculated each portal field edge, as well as reducing processing time in subsequent fractions of an individual portal field by a factor of up to 14. Conclusions: The heuristic edge detection routine is an accurate and fast method for calculating portal field edges and determining field edge setup errors

  17. The Digital Divide and Patient Portals: Internet Access Explained Differences in Patient Portal Use for Secure Messaging by Age, Race, and Income.

    Science.gov (United States)

    Graetz, Ilana; Gordon, Nancy; Fung, Vick; Hamity, Courtnee; Reed, Mary E

    2016-08-01

    Online access to health records and the ability to exchange secure messages with physicians can improve patient engagement and outcomes; however, the digital divide could limit access to web-based portals among disadvantaged groups. To understand whether sociodemographic differences in patient portal use for secure messaging can be explained by differences in internet access and care preferences. Cross-sectional survey to examine the association between patient sociodemographic characteristics and internet access and care preferences; then, the association between sociodemographic characteristics and secure message use with and without adjusting for internet access and care preference. One thousand forty-one patients with chronic conditions in a large integrated health care delivery system (76% response rate). Internet access, portal use for secure messaging, preference for in-person or online care, and sociodemographic and health characteristics. Internet access and preference mediated some of the differences in secure message use by age, race, and income. For example, using own computer to access the internet explained 52% of the association between race and secure message use and 60% of the association between income and use (Sobel-Goodman mediation test, Pdifferences in portal use remained statistically significant when controlling for internet access and preference. As the availability and use of patient portals increase, it is important to understand which patients have limited access and the barriers they may face. Improving internet access and making portals available across multiple platforms, including mobile, may reduce some disparities in secure message use.

  18. Ligation of superior mesenteric vein and portal to splenic vein anastomosis after superior mesenteric-portal vein confluence resection during pancreaticoduodenectomy - Case report.

    Science.gov (United States)

    Tang, Jianlin; Abbas, Jihad; Hoetzl, Katherine; Allison, David; Osman, Mahamed; Williams, Mallory; Zelenock, Gerald B

    2014-12-01

    62 year old Caucasian female with pancreatic head mass abutting the superior mesenteric vein (SMV) presented with fine needle aspiration biopsy confirmed diagnosis of ductal adenocarcinoma. CT scan showed near complete obstruction of portal vein and large SMV collateral development. After 3 months of neoadjuvant therapy, her portal vein flow improved significantly, SMV collateral circulation was diminished. Pancreaticoduodenectomy (PD) and superior mesenteric portal vein (SMPV) confluence resection were performed; A saphenous vein interposition graft thrombosed immediately. The splenic vein remnant was distended and adjacent to the stump of the portal vein. Harvesting an internal jugular vein graft required extra time and using a synthetic graft posed a risk of graft thrombosis or infection. As a result, we chose to perform a direct anastomosis of the portal and splenic vein in a desperate situation. The anastomosis decompressed the mesenteric venous system, so we then ligated the SMV. The patient had an uneventful postoperative course, except transient ascites. She redeveloped ascites more than one year later. At that time a PET scan showed bilateral lung and right femur metastatic disease. She expired 15 months after PD. The lessons we learned are (1) Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2) Synthetic graft is an alternative for internal jugular vein graft. (3) Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4) It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival.

  19. Comparison of computer workstation with light box for detecting setup errors from portal images

    International Nuclear Information System (INIS)

    Boxwala, Aziz A.; Chaney, Edward L.; Fritsch, Daniel S.; Raghavan, Suraj; Coffey, Christopher S.; Major, Stacey A.; Muller, Keith E.

    1999-01-01

    Purpose: Observer studies were conducted to test the hypothesis that radiation oncologists using a computer workstation for portal image analysis can detect setup errors at least as accurately as when following standard clinical practice of inspecting portal films on a light box. Methods and Materials: In a controlled observer study, nine radiation oncologists used a computer workstation, called PortFolio, to detect setup errors in 40 realistic digitally reconstructed portal radiograph (DRPR) images. PortFolio is a prototype workstation for radiation oncologists to display and inspect digital portal images for setup errors. PortFolio includes tools for image enhancement; alignment of crosshairs, field edges, and anatomic structures on reference and acquired images; measurement of distances and angles; and viewing registered images superimposed on one another. The test DRPRs contained known in-plane translation or rotation errors in the placement of the fields over target regions in the pelvis and head. Test images used in the study were also printed on film for observers to view on a light box and interpret using standard clinical practice. The mean accuracy for error detection for each approach was measured and the results were compared using repeated measures analysis of variance (ANOVA) with the Geisser-Greenhouse test statistic. Results: The results indicate that radiation oncologists participating in this study could detect and quantify in-plane rotation and translation errors more accurately with PortFolio compared to standard clinical practice. Conclusions: Based on the results of this limited study, it is reasonable to conclude that workstations similar to PortFolio can be used efficaciously in clinical practice

  20. Use of knowledge-sharing web-based portal in gross and microscopic anatomy.

    Science.gov (United States)

    Durosaro, Olayemi; Lachman, Nirusha; Pawlina, Wojciech

    2008-12-01

    Changes in worldwide healthcare delivery require review of current medical school curricula structure to develop learning outcomes that ensures mastery of knowledge and clinical competency. In the last 3 years, Mayo Medical School implemented outcomes-based curriculum to encompass new graduate outcomes. Standard courses were replaced by 6-week clinically-integrated didactic blocks separated by student-self selected academic enrichment activities. Gross and microscopic anatomy was integrated with radiology and genetics respectively. Laboratory components include virtual microscopy and anatomical dissection. Students assigned to teams utilise computer portals to share learning experiences. High-resolution computed tomographic (CT) scans of cadavers prior to dissection were made available for correlative learning between the cadaveric material and radiologic images. Students work in teams on assigned presentations that include histology, cell and molecular biology, genetics and genomic using the Nexus Portal, based on DrupalEd, to share their observations, reflections and dissection findings. New generation of medical students are clearly comfortable utilising web-based programmes that maximise their learning potential of conceptually difficult and labor intensive courses. Team-based learning approach emphasising the use of knowledge-sharing computer portals maximises opportunities for students to master their knowledge and improve cognitive skills to ensure clinical competency.

  1. Radionuclide and ultrasonic investigations in liver cirrhosis with portal hypertension

    International Nuclear Information System (INIS)

    Khodzhibekov, M.Kh.; Rikhsieva, L.Eh.; Nazyrov, F.G.

    1988-01-01

    Combined radionuclide and ultrasonic investigations (UNI) were performed in 95 patients with liver cirrhosis complicated by portal hypertension. Liver and splenic shape structure and the presence of fluid in the abdominal cavity were assessed in USI. Radionuclide methods of investigation of the hepatic blood flow, assessment of the shape, size and structure of RP distribution in the liver and spleen, and for calculation of the hepatosplenic index. The most significant signs of differentiation of stages of portal hypertension were the presence and amount of fluid in the abdominal cavity and a hepatic blood flow value reflecting the gravity of portal hypertension. Combined radionuclide and ultrasonic investigations permitted a differentiated approach to staging of portal hypertension and assessment of liver and splenic morphofunctional state that could play an important role in the choice of tactics of surgery of liver cirrhosis

  2. Radionuclide and ultrasonic investigations in liver cirrhosis with portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Khodzhibekov, M Kh; Rikhsieva, L Eh; Nazyrov, F G

    1988-08-01

    Combined radionuclide and ultrasonic investigations (UNI) were performed in 95 patients with liver cirrhosis complicated by portal hypertension. Liver and splenic shape structure and the presence of fluid in the abdominal cavity were assessed in USI. Radionuclide methods of investigation of the hepatic blood flow, assessment of the shape, size and structure of RP distribution in the liver and spleen, and for calculation of the hepatosplenic index. The most significant signs of differentiation of stages of portal hypertension were the presence and amount of fluid in the abdominal cavity and a hepatic blood flow value reflecting the gravity of portal hypertension. Combined radionuclide and ultrasonic investigations permitted a differentiated approach to staging of portal hypertension and assessment of liver and splenic morphofunctional state that could play an important role in the choice of tactics of surgery of liver cirrhosis.

  3. Health literacy and patient portals.

    Science.gov (United States)

    Gu, Yulong; Orr, Martin; Warren, Jim

    2015-06-01

    Health literacy has been described as the capacity to obtain, process, and understand basic health information and services needed to make appropriate health decisions. Improving health literacy may serve to promote concordance with therapy, engage patients in their own health care, and improve health outcomes. Patient portal technology aims at enabling patients and families to have easy access to key information in their own medical records and to communicate with their health care providers electronically. However, there is a gap in our understanding of how portals will improve patient outcome. The authors believe patient portal technology presents an opportunity to improve patient concordance with prescribed therapy, if adequate support is provided to equip patients (and family/carers) with the knowledge needed to utilise the health information available via the portals. Research is needed to understand what a health consumer will use patient portals for and how to support a user to realise the technology's potential.

  4. Knowledge Portals: Ontologies at Work

    OpenAIRE

    Staab, Steffen; Maedche, Alexander

    2001-01-01

    Knowledge portals provide views onto domain-specific information on the World Wide Web, thus helping their users find relevant, domain-specific information. The construction of intelligent access and the contribution of information to knowledge portals, however, remained an ad hoc task, requiring extensive manual editing and maintenance by the knowledge portal providers. To diminish these efforts, we use ontologies as a conceptual backbone for providing, accessing, and structuring information...

  5. MR image-guided portal verification for brain treatment field

    International Nuclear Information System (INIS)

    Yin, F.-F.; Gao, Q.H.; Xie, H.; Nelson, D.F.; Yu, Y.; Kwok, W.E.; Totterman, S.; Schell, M.C.; Rubin, P.

    1996-01-01

    and marrow information within the skull. Next, a ray-tracing method is used to generate a projection (pseudo-portal) image at the planned treatment position. In this situation, the ray-tracing is simply performed on pixels rather than attenuation coefficients. The skull and its relative positions are also projected to the pseudo-portal image and are used as 'hint' for the search of similar features in the portal images. A Canny edge detector is applied to the region of treatment field and is used to enhance brain contour and skull. The skull in the brain is then identified using a snake technique which is guided by the ''hint'', the projected features from MR images. Finally, a Chamfer matching technique is used to correlate features between the MR projection and portal images. Results: MR image-guided portal verification technique is evaluated using a clinical patient case who has an astrocytoma brain tumor and is treated by radiation therapy. The segmented results for brain MR slice images indicate that a wavelet-based image segmentation technique provides a reasonable estimation for the brain skull. Compared to the brain portal image, the method developed in this study for the generation of brain projection images provides skull structure about 3 mm differences. However, overall matching results are within 2 mm compared to the results between portal and simulation images. In addition, tumor volume can be accurately visualized in the projection image and be mapped over to portal images for treatment verification with this approach. Conclusions: A method for MR image-guided portal verification of brain treatment field is being developed. Although the projection image from MR images dose not have the similar radiographic appearance as portal images, it provides certain essential anatomical features (landmarks and gross tumor) as well as their relative locations to be used as references for computerized portal verification

  6. Health professionals' attitudes towards using a Web 2.0 portal for child and adolescent diabetes care: qualitative study.

    Science.gov (United States)

    Nordqvist, Cecilia; Hanberger, Lena; Timpka, Toomas; Nordfeldt, Sam

    2009-04-06

    The Internet, created and maintained in part by third-party apomediation, has become a dynamic resource for living with a chronic disease. Modern management of type 1 diabetes requires continuous support and problem-based learning, but few pediatric clinics offer Web 2.0 resources to patients as part of routine diabetes care. To explore pediatric practitioners' attitudes towards the introduction of a local Web portal for providing young type 1 diabetes patients with interactive pedagogic devices, social networking tools, and locally produced self-care and treatment information. Opportunities and barriers related to the introduction of such systems into clinical practice were sought. Twenty clinicians (seven doctors, nine nurses, two dieticians, and two social welfare officers) from two pediatric diabetes teams participated in the user-centered design of a local Web 2.0 portal. After completion of the design, individual semi-structured interviews were performed and data were analyzed using phenomenological methods. The practitioners reported a range of positive attitudes towards the introduction of a local Web 2.0 portal to their clinical practice. Most interviewees were satisfied with how the portal turned out, and a sense of community emerged during the design process and development of the portal's contents. A complementary role was suggested for the portal within the context of health practice culture, where patients and their parents would be able to learn about the disease before, between, and after scheduled contacts with their health care team. Although some professionals expected that email communication with patients and online patient information would save time during routine care, others emphasized the importance of also maintaining face-to-face communication. Online peer-to-peer communication was regarded as a valuable function; however, most clinicians did not expect that the portal would be used extensively for social networking amongst their

  7. Heart/liver ratios and portal vein pressure used in early cirrhosis diagnosis

    International Nuclear Information System (INIS)

    He Jingxiang; Li Wenfan; Liu Chun; Yang Peng; Chen Ming; Wang Hong

    2001-01-01

    Objective: To find a method which not only can comprehensively evaluate the rise of portal pressure, opening and establishment of portal collateral circulation, portal-systemic shunting, and liver and spleen functions in cirrhosis, but also aid the differential diagnosis of early and established cirrhosis. Methods: Heart/liver count (H/L) ratios were obtained at different times after per-rectal administration of 99m Tc-MIBI. Portal venous pressures at different times were calculated using a previously documented formula. The relationship between portal venous pressure and cirrhosis, including its pathological process, was then evaluated. Results: There was obvious discrepancy (t=2.810; p<0.05) in 90-150 minutes portal venous pressures between normal and late hepatitis groups; there was also obvious difference (t=2.348, p<0.05) in portal venous pressures between the cirrhosis group and other groups. The portal venous pressure of early cirrhosis group was also significantly different (t=2.167, p<0.05) from other groups and it was situated between those of normal, and hepatitis and cirrhosis groups. There was obvious diversity (t=2.287, p<0.05) in Child-Pugh classification levels in the late imaging phase. There was positive correlation between calculated portal venous pressure and H/L ratio (r=0.487, p<0.01). Conclusion: Using temporal portal venous recirculation imaging, an early H/L ratio of ≥0.65 and formula-calculated portal venous pressure of ≥1.9 kPa or a portal-systemic venous pressure difference of ≥1.5 kPa indicate cirrhosis; H/L ratio between 0.32 and 0.64 or portal venous pressure between 1.03 to 1.89 kPa suggest early cirrhosis. Our study showed that H/L ratios at specific times and computed portal vein pressure might be important in the diagnosis of hepatitis, impaired hepatic function caused by cirrhosis, portal-systemic shunting, and portal venous recirculation. It is a simple, sensitive, reliable, and non-invasive method, which can be helpful in

  8. TMEM16A regulates portal vein smooth muscle cell proliferation in portal hypertension.

    Science.gov (United States)

    Zeng, Xi; Huang, Ping; Chen, Mingkai; Liu, Shiqian; Wu, Nannan; Wang, Fang; Zhang, Jing

    2018-01-01

    The aim of the present study was to elucidate the effect of transmembrane protein 16A (TMEM16A) on portal vein smooth muscle cell (PVSMC) proliferation associated with portal vein remodeling in portal hypertension (PHT). Sprague-Dawley rats were subjected to bile duct ligation to establish a rat model of liver cirrhosis and PHT. Sham-operated animals served as controls. At 8 weeks after bile duct ligation, the extent of liver fibrosis and the portal vein wall thickness were assessed using hematoxylin-eosin staining. The protein expression levels of TMEM16A, extracellular signal-regulated kinase 1 and 2 (ERK1/2) and phosphorylated ERK1/2 (p-ERK1/2) in the portal vein were detected by immunohistochemistry and western blotting. In vitro , the lentivirus vectors were constructed and transfected into PVSMCs to upregulate the expression of TMEM16A. Isolated rat primary PVSMCs were treated with a small molecule inhibitor of TMEM16A, T16A-inhA01. Cell cycle was detected by flow cytometry. The activity of TMEM16A in the portal vein isolated from bile duct ligated rats was decreased, while the expression level of p-ERK1/2 was increased. However, in vitro , upregulation of TMEM16A promoted the proliferation PVSMCs, while inhibition of TMEM16A channels inhibited the proliferation of PVSMCs. The results indicated that TMEM16A contributes to PVSMCs proliferation in vitro , but in vivo , it may be a negative regulator of cell proliferation influenced by numerous factors.

  9. [Portal perfusion with right gastroepiploic vein flow in liver transplant].

    Science.gov (United States)

    Mendoza-Sánchez, Federico; Javier-Haro, Francisco; Mendoza-Medina, Diego Federico; González-Ojeda, Alejandro; Cortés-Lares, José Antonio; Fuentes-Orozco, Clotilde

    Liver transplantation in patients with liver cirrhosis, portal vein thrombosis, and cavernous transformation of the portal vein, is a complex procedure with high possibility of liver graft dysfunction. It is performed in 2-19% of all liver transplants, and has a significantly high mortality rate in the post-operative period. Other procedures to maintain portal perfusion have been described, however there are no reports of liver graft perfusion using right gastroepiploic vein. A 20 year-old female diagnosed with cryptogenic cirrhosis, with a Child-Pugh score of 7 points (class "B"), and MELD score of 14 points, with thrombosis and cavernous transformation of the portal vein, severe portal hypertension, splenomegaly, a history of upper gastrointestinal bleeding due to oesophageal varices, and left renal agenesis. The preoperative evaluation for liver transplantation was completed, and the right gastroepiploic vein of 1-cm diameter was observed draining to the infrahepatic inferior vena cava and right suprarenal vein. An orthotopic liver transplantation was performed from a non-living donor (deceased on January 30, 2005) using the Piggy-Back technique. Portal vein perfusion was maintained using the right gastroepiploic vein, and the outcome was satisfactory. The patient was discharged 13 days after surgery. Liver transplantation was performed satisfactorily, obtaining an acceptable outcome. In this case, the portal perfusion had adequate blood flow through the right gastroepiploic vein. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  10. United States National Library of Medicine Drug Information Portal.

    Science.gov (United States)

    Hochstein, Colette; Goshorn, Jeanne; Chang, Florence

    2009-01-01

    The Drug Information Portal is a free Web resource from the National Library of Medicine (NLM) that provides a user-friendly gateway to current information for more than 15,000 drugs. The site guides users to related resources of NLM, the National Institutes of Health (NIH), and other government agencies. Current drug-related information regarding consumer health, clinical trials, AIDS, MeSH pharmacological actions, MEDLINE/PubMed biomedical literature, and physical properties and structure is easily retrieved by searching on a drug name. A varied selection of focused topics in medicine and drugs is also available from displayed subject headings. This column provides background information about the Drug Information Portal, as well as search basics.

  11. Three months of simvastatin therapy vs. placebo for severe portal hypertension in cirrhosis: A randomized controlled trial.

    Science.gov (United States)

    Pollo-Flores, Priscila; Soldan, Mônica; Santos, Ubiratan Cassano; Kunz, Danielle Gobbi; Mattos, Denise Espindola; da Silva, Alexandre Cerqueira; Marchiori, Roberta Cabral; Rezende, Guilherme Ferreira da Motta

    2015-11-01

    Pleiotropic effects of statins decrease intrahepatic resistance and portal hypertension. We evaluated the effects of simvastatin on hepatic venous pressure gradient (HVPG) and azygos vein blood flow in cirrhotic patients. A 3-month prospective, randomized, triple-blind trial with simvastatin (40 mg/day) vs. placebo was conducted in patients with cirrhotic portal hypertension. HVPG and azygos blood flow, measured by colour Doppler endoscopic ultrasound, were assessed before and after treatment. The primary endpoint was a decrease in the HVPG of at least 20% from baseline or to ≤12 mmHg after the treatment. 34 patients were prospectively enrolled, and 24 completed the protocol. In the simvastatin group 6/11 patients (55%) presented a clinically relevant decrease in the HVPG; no decrease was observed in the placebo group (p=0.036). Patients with medium/large oesophageal varices and previous variceal bleeding had a higher response rate to simvastatin. HVPG and azygos blood flow values were not correlated. No significant adverse events occurred. Simvastatin lowers portal pressure and may even improve liver function. The haemodynamic effect appears to be more evident in patients with severe portal hypertension. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  12. Web-based Service Portal in Healthcare

    Science.gov (United States)

    Silhavy, Petr; Silhavy, Radek; Prokopova, Zdenka

    Information delivery is one the most important task in healthcare. The growing sector of electronic healthcare has an important impact on the information delivery. There are two basic approaches towards information delivering. The first is web portal and second is touch-screen terminal. The aim of this paper is to investigate the web-based service portal. The most important advantage of web-based portal in the field of healthcare is an independent access for patients. This paper deals with the conditions and frameworks for healthcare portals

  13. Meaningful use in the safety net: a rapid ethnography of patient portal implementation at five community health centers in California.

    Science.gov (United States)

    Ackerman, Sara L; Sarkar, Urmimala; Tieu, Lina; Handley, Margaret A; Schillinger, Dean; Hahn, Kenneth; Hoskote, Mekhala; Gourley, Gato; Lyles, Courtney

    2017-09-01

    US health care institutions are implementing secure websites (patient portals) to achieve federal Meaningful Use (MU) certification. We sought to understand efforts to implement portals in "safety net" health care systems that provide services for low-income populations. Our rapid ethnography involved visits at 4 California safety net health systems and in-depth interviews at a fifth. Visits included interviews with clinicians and executives ( n  = 12), informal focus groups with front-line staff ( n  = 35), observations of patient portal sign-up procedures and clinic work, review of marketing materials and portal use data, and a brief survey ( n  = 45). Our findings demonstrate that the health systems devoted considerable effort to enlisting staff support for portal adoption and integrating portal-related work into clinic routines. Although all health systems had achieved, or were close to achieving, MU benchmarks, patients faced numerous barriers to portal use and our participants were uncertain how to achieve and sustain "meaningful use" as defined by and for their patients. Health systems' efforts to achieve MU certification united clinic staff under a shared ethos of improved quality of care. However, MU's assumptions about patients' demand for electronic access to health information and ability to make use of it directed clinics' attention to enrollment and message routing rather than to the relevance and usability of a tool that is minimally adaptable to the safety net context. We found a mismatch between MU-based metrics of patient engagement and the priorities and needs of safety net patient populations. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  14. Effects of a long-acting formulation of octreotide on renal function and renal sodium handling in cirrhotic patients with portal hypertension: a randomized, double-blind, controlled trial

    DEFF Research Database (Denmark)

    Ottesen, L.H.; Aagaard, Niels Kristian; Kiszka-Kanowitz, M.

    2001-01-01

    variable effects. Twenty-five cirrhotic patients with portal hypertension were randomized in a double-blind design to placebo or a single subcutaneous dose of a long-acting formulation of octreotide (octreotide-LAR) (20 mg). Renal function tests were performed before dosing and repeated after 30 days...... with octreotide-LAR. It is concluded that in spite of increased arterial pressure, octreotide-LAR has no significant effect on renal hemodynamics and tubular function in clinically stable cirrhotic patients with portal hypertension....

  15. Fine-needle percutaneous transhepatic parenchymal portal venography by using carbon dioxide: a pilot study in pigs

    International Nuclear Information System (INIS)

    Sun, Fei; Hernandez, Javier; Crisostomo, Veronica; Pineda, Luis-Fernando; Lima, Juan Rafael; Uson, Jesus; Maynar, Manuel

    2003-01-01

    Our purpose was to evaluate the feasibility and safety of carbon dioxide (CO 2 ) in fine-needle percutaneous transhepatic parenchymal portal venography and its potential clinical applications. Three Belgian landrace pigs received fine-needle percutaneous transhepatic parenchymal portal venography by using CO 2 as a contrast agent. Under fluoroscopic and B-mode ultrasonic guidance, right or left lobe of liver was punctured with a 22-G Chiba needle, through which CO 2 was injected with a dedicated CO 2 injector at injection rate of 20 ml/s for 20 ml, 40 ml/s for 40 ml, 40 ml/s for 60 ml, and 40 ml/s for 80 ml, respectively. The portal venograms were obtained by use of digital subtraction angiography (DSA) system with animal in supine position. In one pig transarterial portal venography was performed, in addition, using iodinated contrast agent. The portal vein was visualized in each run of venography. Optimal images of portal tree structure up to four-order branches were obtained in all those with CO 2 injection rate of 40 ml/s, which appeared much better in quality than those obtained by cranial mesenteric arteriography with iodinated contrast agent. No extravasation of CO 2 , liver laceration, or any other complication occurred during the procedures. The technique we proposed demonstrated optimal portography, which appeared to be safe, minimally invasive, less time-consuming, cost-effective, and easy to perform, with great potential in clinical applications. (orig.)

  16. Staged Transcatheter Treatment of Portal Hypoplasia and Congenital Portosystemic Shunts in Children

    International Nuclear Information System (INIS)

    Bruckheimer, Elchanan; Dagan, Tamir; Atar, Eli; Schwartz, Michael; Kachko, Ludmila; Superina, Riccardo; Amir, Gabriel; Shapiro, Rivka; Birk, Einat

    2013-01-01

    Purpose: Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Methods: Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by ∼50 %. Recatheterization was performed approximately 3 months later. If the portal pressure was below 18 mmHg and vessels had developed, the shunt was closed with a device. Results: Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5–13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2–8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 ± 11.3 to 10.8 ± 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 ± 0.5 to 4.0 ± 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 ± 53.6 to 65.7 ± 9.6 μmol/L; p = 0.002) with no complications. Conclusion: Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia

  17. Portal Hypertension in Patients with Liver Cirrhosis: Diagnostic Accuracy of Spleen Stiffness.

    Science.gov (United States)

    Takuma, Yoshitaka; Nouso, Kazuhiro; Morimoto, Youichi; Tomokuni, Junko; Sahara, Akiko; Takabatake, Hiroyuki; Matsueda, Kazuhiro; Yamamoto, Hiroshi

    2016-05-01

    To evaluate the accuracy of spleen stiffness (SS) and liver stiffness (LS) measured by using acoustic radiation force impulse imaging in the diagnosis of portal hypertension in patients with liver cirrhosis, with the hepatic venous pressure gradient (HVPG) as a reference standard. Institutional review board approval and informed consent were obtained for this prospective single-center study. From February 2012 to August 2013, 60 patients with liver cirrhosis (mean age, 70.8 years; age range, 34-88 years; 34 men, 26 women) with HVPG, LS, and SS measurements and gastrointestinal endoscopy and laboratory data were included if they met the following criteria: no recent episodes of gastrointestinal bleeding, no history of splenectomy, no history of partial splenic embolization, no history of β-blocker therapy, and absence of portal thrombosis. The efficacy of the parameters for the evaluation of portal hypertension was analyzed by using the Spearman rank-order correlation coefficient and receiver operating characteristic (ROC) curve analysis. The correlation coefficient between SS and HVPG (r = 0.876) was significantly better than that between LS and HVPG (r = 0.609, P portal hypertension (HVPG ≥ 10 mm Hg), severe portal hypertension (HVPG ≥ 12 mm Hg), esophageal varices (EVs), and high-risk EVs were significantly higher (0.943, 0.963, 0.937, and 0.955, respectively) than those of LS, spleen diameter, platelet count, and platelet count to spleen diameter ratio (P portal hypertension, severe portal hypertension, EVs, and high-risk EVs (negative likelihood ratios, 0.051, 0.056, 0.054, and 0.074, respectively). SS is reliable and has better diagnostic performance than LS for identifying portal hypertension in liver cirrhosis. (©) RSNA, 2015 Online supplemental material is available for this article.

  18. Intelligent interaction based on holographic personalized portal

    Directory of Open Access Journals (Sweden)

    Yadong Huang

    2017-06-01

    Full Text Available Purpose – The purpose of this paper is to study the architecture of holographic personalized portal, user modeling, commodity modeling and intelligent interaction. Design/methodology/approach – In this paper, the authors propose crowd-science industrial ecological system based on holographic personalized portal and its interaction. The holographic personality portal is based on holographic enterprises, commodities and consumers, and the personalized portal consists of accurate ontology, reliable supply, intelligent demand and smart cyberspace. Findings – The personalized portal can realize the information acquisition, characteristic analysis and holographic presentation. Then, the intelligent interaction, e.g. demand decomposition, personalized search, personalized presentation and demand prediction, will be implemented within the personalized portal. Originality/value – The authors believe that their work on intelligent interaction based on holographic personalized portal, which has been first proposed in this paper, is innovation focusing on the interaction between intelligence and convenience.

  19. Comprehensive fluence model for absolute portal dose image prediction

    International Nuclear Information System (INIS)

    Chytyk, K.; McCurdy, B. M. C.

    2009-01-01

    Amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) continue to be investigated as treatment verification tools, with a particular focus on intensity modulated radiation therapy (IMRT). This verification could be accomplished through a comparison of measured portal images to predicted portal dose images. A general fluence determination tailored to portal dose image prediction would be a great asset in order to model the complex modulation of IMRT. A proposed physics-based parameter fluence model was commissioned by matching predicted EPID images to corresponding measured EPID images of multileaf collimator (MLC) defined fields. The two-source fluence model was composed of a focal Gaussian and an extrafocal Gaussian-like source. Specific aspects of the MLC and secondary collimators were also modeled (e.g., jaw and MLC transmission factors, MLC rounded leaf tips, tongue and groove effect, interleaf leakage, and leaf offsets). Several unique aspects of the model were developed based on the results of detailed Monte Carlo simulations of the linear accelerator including (1) use of a non-Gaussian extrafocal fluence source function, (2) separate energy spectra used for focal and extrafocal fluence, and (3) different off-axis energy spectra softening used for focal and extrafocal fluences. The predicted energy fluence was then convolved with Monte Carlo generated, EPID-specific dose kernels to convert incident fluence to dose delivered to the EPID. Measured EPID data were obtained with an a-Si EPID for various MLC-defined fields (from 1x1 to 20x20 cm 2 ) over a range of source-to-detector distances. These measured profiles were used to determine the fluence model parameters in a process analogous to the commissioning of a treatment planning system. The resulting model was tested on 20 clinical IMRT plans, including ten prostate and ten oropharyngeal cases. The model predicted the open-field profiles within 2%, 2 mm, while a mean of 96.6% of pixels over all

  20. Very Early Presentation of Extrahepatic Portal Vein Obstruction Causing Portal Hypertension in an Infant: Uncertainties in the Management and Therapeutic Limitations

    Directory of Open Access Journals (Sweden)

    Parisá Khodayar-Pardo

    2016-07-01

    Full Text Available Extrahepatic portal vein obstruction, although rare in children, is a significant cause of portal hypertension (PHT leading to life-threatening gastrointestinal bleeding in the pediatric age group. PHT may also lead to other complications such as hyperesplenism, cholangyopathy, ascites, and even hepatopulmonary syndrome and portopulmonary hypertension that may require organ transplantation. Herein we report the case of an asymptomatic 11-month-old infant wherein a hepatomegaly and cavernous transformation of the portal vein was detected by liver ultrasound. Neither signs of thrombosis in arteriovenous system, nor affectation of biliary tract were identified in the magnetic resonance imaging study. A significant enlargement of the caudate lobe of the liver was reported. No risk factors were detected. The differential diagnosis performed was extensive. Inherited thrombophilia and storage disorders were especially considered. Liver biopsy was normal. Upper gastrointestinal esophagogastroduodenoscopy detected two small varicose cords on the distal third of the esophagus. Finding a cavernous transformation of the portal vein with evidence of collateral circulation in such an early age is a challenging condition for professionals, since PHT may lead to severe complications during childhood and can compromise growth and development. Evidence-based guidelines for the management of PHT in adults have been published. However, follow-up and treatment of pediatric patients have not yet been standardized. Moreover, management of PHT in infants faces particular difficulties such as technical restrictions that could hinder their treatment.

  1. Radioisotopic evaluation of portal circulation

    International Nuclear Information System (INIS)

    Maliska, C.; Rosenthal, D.

    1986-01-01

    The use of a radio-tracer of portal circulation through the intestine, should prevent cruel punctures in the portal-vein or spleen as it is usually the case with traditional methods in the study of portal-system. The absorption of I-131 and Tc-99m, previously cheked in rabbits presented similar results in dogs. The time of circulation between terminal large-intestine and the liver (t-RF) was determined by external counting at hepatic level by recording radioactivity variation-time. In healthy animals the t-RF was from 20to 60 seconds, with average time of 42 seconds. In 2 animals with partial binding of portal-vein the t-RF went up to 110 and 120 seconds. (Author) [pt

  2. Von Willebrand factor indicates bacterial translocation, inflammation, and procoagulant imbalance and predicts complications independently of portal hypertension severity.

    Science.gov (United States)

    Mandorfer, M; Schwabl, P; Paternostro, R; Pomej, K; Bauer, D; Thaler, J; Ay, C; Quehenberger, P; Fritzer-Szekeres, M; Peck-Radosavljevic, M; Trauner, M; Reiberger, T; Ferlitsch, A

    2018-04-01

    Elevated plasma von Willebrand factor antigen (vWF) has been shown to indicate the presence of clinically significant portal hypertension, and thus, predicts the development of clinical events in patients with cirrhosis. To investigate the impact of bacterial translocation and inflammation on vWF, as well as the association between vWF and procoagulant imbalance. Moreover, we assessed whether vWF predicts complications of cirrhosis, independent of the severity of portal hypertension. Our study population comprised 225 patients with hepatic venous pressure gradient (HVPG) ≥ 10 mm Hg without active bacterial infections or hepatocellular carcinoma. vWF correlated with markers of bacterial translocation (lipopolysaccharide-binding protein [LBP; ρ = 0.201; P = 0.021]), inflammation (interleukin 6 [IL-6; ρ = 0.426; P protein [CRP; ρ = 0.249; P protein C ratio; ρ = 0.507; P model for transplant-free mortality. Finally, the independent prognostic value of vWF/CRP groups for mortality was confirmed by competing risk analysis. Our results demonstrate that vWF is not only a marker of portal hypertension but also independently linked to bacterial translocation, inflammation and procoagulant imbalance, which might explain its HVPG-independent association with most clinical events. Prognostic groups based on vWF/CRP efficiently discriminate between patients with a poor 5-year survival and patients with a favourable prognosis. © 2018 John Wiley & Sons Ltd.

  3. Radiation portal evaluation parameters

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    The detection of the unauthorized movement of radioactive materials is one of the most effective nonproliferation measures. Automatic special nuclear material (SNM) portal monitors are designed to detect this unauthorized movement and are an important part of the safeguard systems at US nuclear facilities. SNM portals differ from contamination monitors because they are designed to have high sensitivity for the low energy gamma-rays associated with highly enriched uranium (HEU) and plutonium. These instruments are now being installed at international borders to prevent the spread of radioactive contamination an SNM. In this paper the parameters important to evaluating radiation portal monitors are discussed. (author)

  4. ELECTRONIC COMMERCE PORTAL

    OpenAIRE

    Georgeta Soava

    2011-01-01

    Today companies are faced with the need to exploit technology changing computer environments, in order to improve customer satisfaction and reduce costs. A successful approach to electronic portals is an effective demonstration of the new ways of relating to the client. The objectives that we have considered for the realization of e-commerce portal can be summarized as follows: structured communication, effective collaboration, complet and closed circuit of orders and deliveries, inventory op...

  5. Splenic embolization in cirrhotic patients with portal hypertension. US findings

    Energy Technology Data Exchange (ETDEWEB)

    Falappa, P G; Cotroneo, A R; De Cinque, M; Maresca, G; Patane' , D

    1988-01-01

    Over the last four years the authors performed transcatheter embolization of the splenic artery by Gianturco coils in 32 consecutive cirrhotic patients with portal hypertension, splenomegaly, cytopenia and gastro-esophageal varices endoscopically proved. This procedure was especially useful for treatement of splenomegaly and cytopenia because a constant reduction of spleen dimensions and increase in platelet count were registered. The effectiveness of transcatheter embolization and follow-up are based on clinic, hematologic and sonographic findings. Sonographic monitoring is believed to be very useful both to evaluate splenomegaly and signs of portal hypertension and to reveal splenic complications (abscesses). Severe complications have been never registered. 21 refs.

  6. Management of Anticoagulation for Portal Vein Thrombosis in Individuals with Cirrhosis: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Geneviève Huard

    2012-01-01

    Full Text Available Non-neoplastic portal vein thrombosis (PVT is an increasingly recognized complication of liver cirrhosis. It is often diagnosed fortuitously and can be either partial or complete. The clinical significance of PVT is not obvious except in some situations such as when patients are on the waiting list for liver transplantation. The only known therapy is anticoagulation which has been shown to permit the disappearance of thrombosis and to prevent further extension. Anticoagulation is a challenging therapy in individuals with liver cirrhosis because of the well-recognized coagulation abnormalities observed in that setting and because of the increased risk of bleeding, especially from gastrointestinal tract caused by portal hypertension. We herein review the current knowledge on that topic in order to highlight the advantages and disadvantages of the currently proposed therapeutic attitudes in face of the diagnosis of PVT in individuals with cirrhosis.

  7. Dosimetric verification of radiation therapy including intensity modulated treatments, using an amorphous-silicon electronic portal imaging device

    Science.gov (United States)

    Chytyk-Praznik, Krista Joy

    Radiation therapy is continuously increasing in complexity due to technological innovation in delivery techniques, necessitating thorough dosimetric verification. Comparing accurately predicted portal dose images to measured images obtained during patient treatment can determine if a particular treatment was delivered correctly. The goal of this thesis was to create a method to predict portal dose images that was versatile and accurate enough to use in a clinical setting. All measured images in this work were obtained with an amorphous silicon electronic portal imaging device (a-Si EPID), but the technique is applicable to any planar imager. A detailed, physics-motivated fluence model was developed to characterize fluence exiting the linear accelerator head. The model was further refined using results from Monte Carlo simulations and schematics of the linear accelerator. The fluence incident on the EPID was converted to a portal dose image through a superposition of Monte Carlo-generated, monoenergetic dose kernels specific to the a-Si EPID. Predictions of clinical IMRT fields with no patient present agreed with measured portal dose images within 3% and 3 mm. The dose kernels were applied ignoring the geometrically divergent nature of incident fluence on the EPID. A computational investigation into this parallel dose kernel assumption determined its validity under clinically relevant situations. Introducing a patient or phantom into the beam required the portal image prediction algorithm to account for patient scatter and attenuation. Primary fluence was calculated by attenuating raylines cast through the patient CT dataset, while scatter fluence was determined through the superposition of pre-calculated scatter fluence kernels. Total dose in the EPID was calculated by convolving the total predicted incident fluence with the EPID-specific dose kernels. The algorithm was tested on water slabs with square fields, agreeing with measurement within 3% and 3 mm. The

  8. Novel Rat Model of Repetitive Portal Venous Embolization Mimicking Human Non-Cirrhotic Idiopathic Portal Hypertension

    DEFF Research Database (Denmark)

    Klein, Sabine; Hinüber, Christian; Hittatiya, Kanishka

    2016-01-01

    BACKGROUND: Non-cirrhotic idiopathic portal hypertension (NCIPH) is characterized by splenomegaly, anemia and portal hypertension, while liver function is preserved. However, no animal models have been established yet. This study assessed a rat model of NCIPH and characterized the hemodynamics......, and compared it to human NCIPH. METHODS: Portal pressure (PP) was measured invasively and coloured microspheres were injected in the ileocecal vein in rats. This procedure was performed weekly for 3 weeks (weekly embolization). Rats without and with single embolization served as controls. After four weeks (one...... in the weekly embolization group. Fibrotic markers αSMA and Desmin were upregulated in weekly embolized rats. DISCUSSION: This study establishes a model using repetitive embolization via portal veins, comparable with human NCIPH and may serve to test new therapies....

  9. Drilling the femoral tunnel during ACL reconstruction: transtibial versus anteromedial portal techniques.

    Science.gov (United States)

    Tudisco, Cosimo; Bisicchia, Salvatore

    2012-08-01

    Incorrect bone tunnel position, particularly on the femoral side, is a frequent cause of failed anterior cruciate ligament reconstruction. Several studies have reported that drilling the femoral tunnel through the anteromedial portal allows a more anatomical placement on the lateral femoral condyle and higher knee stability than does transtibial reconstruction.In the current study, the femoral tunnel was drilled with transtibial (n=6) and anteromedial (n=6) portal techniques in 12 cadaveric knees. With appropriate landmarks inserted into bone tunnels, the direction and length of the tunnels were determined on anteroposterior and lateral radiographs. Knee stability was evaluated with a KT1000 arthrometer (MEDmetric Corporation, San Diego, California) and pivot shift test, comparing the pre- and postoperative values of both techniques. Finally, all knees were dissected to enhance vision of the insertion of the reconstructed ligament. The anteromedial portal technique led to better placement of the femoral tunnel in the coronal and sagittal planes, with higher knee stability according to the pivot shift test but not the KT1000 arthrometer. Anatomical and clinical results reported in the literature on transtibial and anteromedial portal techniques are controversial, but most of studies report better results with the anteromedial portal technique, especially regarding rotational stability. The current cadaveric study showed that the anteromedial portal technique provided better tunnel placement on the lateral femoral condyle in the coronal and sagittal planes, with an improvement in the rotational stability of the knee. Copyright 2012, SLACK Incorporated.

  10. Relevance of plasma malondialdehyde level and severity of portal hypertension in cirrhotic patients.

    Science.gov (United States)

    Wang, Sheng-Lan; Zhu, Xin-Yan; Zhang, Dong-Wei; Zhang, Zhao-Jie; Gao, Heng-Jun; Yang, Chang-Qing

    2015-01-01

    Portal hypertension is one of the death reasons for the liver cirrhosis patients. The oxidative stress is related to the occurrence and development of portal hypertension in cirrhosis. Malondialdehyde (MDA), one of the lipid peroxides, increases substantially in cirrhotic patients. To evaluate the relevance between the MDA level and portal hypertension in cirrhotic patients. 60 liver cirrhotic patients and 30 healthy controls were enrolled. The plasma MDA level and general blood tests including ALT, AST, ALB, total bilirubin, and platelet were measured. All people enrolled accepted endoscopic examination and B-Ultrasound check to evaluate the severity of portal hypertension. The MDA plasma level of cirrhotic patients was significantly higher than the controls (Pportal hypertension (Pportal vein (r=0.652, Pportal hypertension. Plasma MDA level may correlate with the severity of portal hypertension in cirrhotic patients.

  11. A clinical predictor of varices and portal hypertensive gastropathy in patients with chronic liver disease

    Directory of Open Access Journals (Sweden)

    Yang Won Min

    2012-06-01

    Full Text Available Background/AimsThe aim of this study was to identify the parameters that could noninvasively predict the presence of esophageal/gastric varices and portal hypertensive gastropathy (PHG in patients with chronic liver disease (CLD, and to determine the accuracy of those parameters.MethodsWe retrospectively analyzed 232 patients with CLD who underwent both upper endoscopy and liver CT within an interval of 3 months. The multidimensional index (M-Index for spleen volume was obtained from the multiplication of splenic length, width, and thickness, as measured by computer tomography.ResultsThe multivariate analysis revealed that platelet, albumin, and M-Index were independently associated with the presence of varices and PHG. We combined three independent parameters, and developed a varices and portal hypertensive gastropathy (VAP scoring system (=[platelet count (/mm3×albumin (g/dL]/[M-Index (cm3]. The area under the receiver operating characteristic curve of the VAP score was 0.850 (95% confidence interval, 0.801-0.899. The VAP cut-off value of 861 had a sensitivity of 85.3%, a positive likelihood ratio of 3.17, and a negative predictive value of 86.4%. For predicting high-risk lesions for bleeding, with a cut-off value of 861 the sensitivity was 92.0%, the positive likelihood ratio was 2.20, and the negative predictive value was 96.4%.ConclusionsThe VAP score can predict the presence of varices and PHG in patients with CLD and may increase the cost-benefit of screening endoscopy in the clinical practice setting. A prospective validation study is necessary in the future.

  12. Prevalence and Indicators of Portal Hypertension in Patients with Nonalcoholic Fatty Liver Disease

    Science.gov (United States)

    Mendes, Flavia D.; Suzuki, Ayako; Sanderson, Schuyler O.; Lindor, Keith D.; Angulo, Paul

    2012-01-01

    Background & Aims Little is known about the prevalence and severity of portal hypertension in patients with non-alcoholic fatty liver disease (NAFLD). We investigated the prevalence and non-invasive predictors of portal hypertension in patients with NAFLD. Methods Signs of portal hypertension, including esophageal varices, splenomegaly, portosystemic encephalopathy, and ascites where investigated in 354 patients with NAFLD. Results One-hundred patients had portal hypertension at the time of NAFLD diagnosis (28.2%), 88 of these with septal fibrosis or cirrhosis (88%). Fibrosis stage correlated with presence (r=0.41, Pportal hypertension. Of the 204 patients with no or mild fibrosis (stages 0–2), 12 had portal hypertension (6%); they had a significantly higher grade of steatosis, based on biopsy analysis, compared to the 192 patients without portal hypertension (94%). Thrombocytopenia, hyperbilirubinemia, cirrhosis, and obesity were independently associated with portal hypertension. Esophageal varices were found in 57 of the 128 patients undergoing endoscopic screening (44.5%) and independently associated with thrombocytopenia, type 2 diabetes, and splenomegaly. Conclusions Signs of portal hypertension are present in 25% of patients at the time of diagnosis of NAFLD; most had advanced fibrosis or cirrhosis. Portal hypertension can occur in a small proportion of patients with mild or no fibrosis and is associated with the extent of steatosis. Features of advanced liver disease and insulin resistance might identify patients with NAFLD and portal hypertension, and those expected to derive the most benefit from endoscopic screening for esophageal varices. PMID:22610002

  13. [Predictive value of ultrasonography in portal hypertension].

    Science.gov (United States)

    Moreno, E; Torres, P; Trejo, C; Barra Ostoni, V; Ortega, C; Römer, H

    1991-01-01

    Portal hypertension is a common pathology in childhood and one of its most common causes is cavernomatosis of the portal vein. This obstruction causes hemodynamic changes which lead to splenomegaly and collateral circulation. Esophageal varices are one of the most important sequelae, which endanger the patient's life because of a bleeding tendency. Ecosonography helps to detect the thickening of the lesser omentum vis a vis the aortic diameter, caused by the collateral circulation. We studied 15 children presenting with portal hypertension resulting from portal vein cavernomatosis; we performed an upper GI endoscopy and abdominal ecosonography. The endoscopy revealed grade II esophageal varices in 20% of cases, the remaining 80% had grade III and grade IV. Ecosonography revealed an increased lesser omentum/aorta ratio in children with portal hypertension, compared to controls (p portal hypertension.

  14. Correlation of transient elastography with hepatic venous pressure gradient in patients with cirrhotic portal hypertension: A study of 326 patients from India.

    Science.gov (United States)

    Kumar, Ashish; Khan, Noor Muhammad; Anikhindi, Shrihari Anil; Sharma, Praveen; Bansal, Naresh; Singla, Vikas; Arora, Anil

    2017-01-28

    To study the diagnostic accuracy of transient elastography (TE) for detecting clinically significant portal hypertension (CSPH) in Indian patients with cirrhotic portal hypertension. This retrospective study was conducted at the Institute of Liver, Gastroenterology, and Pancreatico-Biliary Sciences, Sir Ganga Ram Hospital, New Delhi, on consecutive patients with cirrhosis greater than 15 years of age who underwent hepatic venous pressure gradient (HVPG) and TE from July 2011 to May 2016. Correlation between HVPG and TE was analyzed using the Spearman's correlation test. Receiver operating characteristic (ROC) curves were prepared for determining the utility of TE in predicting various stages of portal hypertension. The best cut-off value of TE for the diagnosis of CSPH was obtained using the Youden index. The study included 326 patients [median age 52 (range 16-90) years; 81% males]. The most common etiology of cirrhosis was cryptogenic (45%) followed by alcohol (34%). The median HVPG was 16.0 (range 1.5 to 30.5) mmHg. Eighty-five percent of patients had CSPH. A significant positive correlation was noted between TE and HVPG (rho 0.361, P portal hypertension. A cut-off TE value of 21.6 kPa identifies CSPH with a PPV of 93%.

  15. Preferences of Current and Potential Patients and Family Members Regarding Implementation of Electronic Communication Portals in Intensive Care Units.

    Science.gov (United States)

    Brown, Samuel M; Bell, Sigall K; Roche, Stephanie D; Dente, Erica; Mueller, Ariel; Kim, Tae-Eun; O'Reilly, Kristin; Lee, Barbara Sarnoff; Sands, Ken; Talmor, Daniel

    2016-03-01

    The quality of communication with patients and family members in intensive care units (ICUs) is a focus of current interest for clinical care improvement. Electronic communication portals are commonly used in other healthcare settings to improve communication. We do not know whether patients and family members desire such portals in ICUs, and if so, what functionality they should provide. To define interest in and desired elements of an electronic communication portal among current and potential ICU patients and their family members. We surveyed, via an Internet panel, 1,050 English-speaking adults residing in the United States with a personal or family history of an ICU admission within 10 years (cohort A) and 1,050 individuals without a history of such admission (cohort B). We also administered a survey instrument in person to 105 family members of patients currently admitted to ICUs at an academic medical center in Boston (cohort C). Respondents, especially current ICU family members, supported an electronic communication portal, including access via an electronic tablet. They wanted at least daily updates, one-paragraph summaries of family meetings including a list of key decisions made, and knowledge of the role and experience of treating clinicians. Overall, they preferred detailed rather than "big picture" information. Respondents were generally comfortable sharing information with their family members. Preferences regarding a communication portal varied significantly by age, sex, ethnicity, and prior experience with ICU hospitalization. Electronic communication portals appear welcome in contemporary ICUs. Frequent updates, knowledge about the professional qualifications of clinicians, detailed medical information, and documentation of family meetings are particularly desired.

  16. The Higgs Portal and Cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Assamagan, Ketevi [Brookhaven National Lab. (BNL), Upton, NY (United States); Chen, Chien-Yi [Perimeter Inst. for Theoretical Physics, Waterloo, ON (Canada); Univ. of Victoria, BC (Canada); Chou, John Paul [Rutgers Univ., Piscataway, NJ (United States); Curtin, David [Univ. of Maryland, College Park, MD (United States); Fedderke, Michael A. [Univ. of Chicago, IL (United States); Gershtein, Yuri [Rutgers Univ., Piscataway, NJ (United States); He, Xiao-Gang [Shanghai Jiao Tong Univ. (China); Klute, Markus [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Kozaczuk, Jonathon [TRIUMF, Vancouver, BC (Canada); Kotwal, Ashutosh [Duke Univ., Durham, NC (United States); Lowette, Steven [Vrije Univ., Brussels (Belgium); No, Jose Miguel [Univ. of Sussex, Brighton (United Kingdom); Plehn, Tilman [Heidelberg Univ. (Germany); Qian, Jianming [Univ. of Michigan, Ann Arbor, MI (United States); Ramsey-Musolf, Michael [Univ. of Massachusetts, Amherst, MA (United States); Safonov, Alexei [Texas A & M Univ., College Station, TX (United States); Shelton, Jessie [Univ. of Illinois, Urbana-Champaign, IL (United States); Spannowsky, Michael [Durham Univ. (United Kingdom); Su, Shufang [Univ. of Arizona, Tucson, AZ (United States); Walker, Devin G. E. [Univ. of Washington, Seattle, WA (United States); Willocq, Stephane [Univ. of Massachusetts, Amherst, MA (United States); Winslow, Peter [Univ. of Massachusetts, Amherst, MA (United States)

    2016-04-18

    Higgs portal interactions provide a simple mechanism for addressing two open problems in cosmology: dark matter and the baryon asymmetry. In the latter instance, Higgs portal interactions may contain the ingredients for a strong first-order electroweak phase transition as well as new CP-violating interactions as needed for electroweak baryogenesis. These interactions may also allow for a viable dark matter candidate. We survey the opportunities for probing the Higgs portal as it relates to these questions in cosmology at the LHC and possible future colliders.

  17. The peculiarities of macroscopic status of the upper gastrointestinal tract mucosa in patients with hepatic and extrahepatic portal hypertension

    Directory of Open Access Journals (Sweden)

    Stepanov Yu.M.

    2018-03-01

    Full Text Available Identification of endoscopic signs of concomitant pathology of the upper gastrointestinal tract allows to determine the tactics of managing patients with different forms of portal hypertension (PG. The analysis of macroscopic picture of esophagus, stomach and duodenum mucosa was carried out in 104 patients with portal hypertension (88 patients with hepatic portal hypertension, 46 – with extrahepatic portal hypertension, 16 – without portal hypertension. The frequency of changes in the esophagus, specific for gastroesophageal reflux disease did not differ significantly in the researched groups. The frequency and severity of varicose veins of the esophagus were diagnosed more often in patients with hepatic form of portal hypertension (OR=10.0, p<0.05. The predominance of different pathological changes of the gastric mucosa in patients with extrahepatic form of portal hypertension was revealed. Portal gastropathy in this group was 5.3 times higher than in patients with hepatic hypertension and 21 times higher than in the III group (without portal hypertension (p<0.01. There were no significant differences of endoscopic picture of the duodenum mucosa between the researched groups.

  18. Portal Vein Dopplerflowmetry in healthy sheep according to age

    Directory of Open Access Journals (Sweden)

    Alexandra F. Belotta

    Full Text Available ABSTRACT: Pulsed Doppler ultrasound was used to evaluate portal blood flow, portal velocity and portal congestion index in 24 healthy sheep divided into groups (lambs, yearlings and ewes, according to age. Measurements were performed at the 11th right intercostal space using ideal insonation angle and uniform insonation method. Mean values obtained in each group were compared with one-way ANOVA, followed by Tukey post-hoc test. Portal velocity and portal blood flow were statistically similar between the groups (P>0.05. Mean portal velocity were 17.75; 17.13 and 16.75; while mean portal blood flow were 26.65; 31.04 and 24.32 for lambs, yearlings and ewes, respectively. Portal congestion index was statistically distinct between the groups and values for lambs, yearlings and ewes were 0.009; 0.058 and 0.09, respectively (P<0.01. Statistical differences were observed in portal vein diameter, portal vein area and portal congestion index between the groups, presumably due to influence of weight and not to age.

  19. Spironolactone lowers portal hypertension by inhibiting liver fibrosis, ROCK-2 activity and activating NO/PKG pathway in the bile-duct-ligated rat.

    Directory of Open Access Journals (Sweden)

    Wei Luo

    Full Text Available OBJECTIVE: Aldosterone, one of the main peptides in renin angiotensin aldosterone system (RAAS, has been suggested to mediate liver fibrosis and portal hypertension. Spironolactone, an aldosterone antagonist, has beneficial effect on hyperdynamic circulation in clinical practice. However, the mechanisms remain unclear. The present study aimed to investigate the role of spionolactone on liver cirrhosis and portal hypertension. METHODS: Liver cirrhosis was induced by bile duct ligation (BDL. Spironolactone was administered orally (20 mg/kg/d after bile duct ligation was performed. Liver fibrosis was assessed by histology, Masson's trichrome staining, and the measurement of hydroxyproline and type I collagen content. The activation of HSC was determined by analysis of alpha smooth muscle actin (α-SMA expression. Protein expressions and protein phosphorylation were determined by immunohistochemical staining and Western blot analysis, Messenger RNA levels by quantitative real time polymerase chain reaction (Q-PCR. Portal pressure and intrahepatic resistance were examined in vivo. RESULTS: Treatment with spironolactone significantly lowered portal pressure. This was associated with attenuation of liver fibrosis, intrahepatic resistance and inhibition of HSC activation. In BDL rat liver, spironolactone suppressed up-regulation of proinflammatory cytokines (TNFα and IL-6. Additionally, spironolactone significantly decreased ROCK-2 activity without affecting expression of RhoA and Ras. Moreover, spironolactone markedly increased the levels of endothelial nitric oxide synthase (eNOS, phosphorylated eNOS and the activity of NO effector-protein kinase G (PKG in the liver. CONCLUSION: Spironolactone lowers portal hypertension by improvement of liver fibrosis and inhibition of intrahepatic vasoconstriction via down-regulating ROCK-2 activity and activating NO/PKG pathway. Thus, early spironolactone therapy might be the optional therapy in cirrhosis and

  20. Ligation of superior mesenteric vein and portal to splenic vein anastomosis after superior mesenteric-portal vein confluence resection during pancreaticoduodenectomy – Case report

    Science.gov (United States)

    Tang, Jianlin; Abbas, Jihad; Hoetzl, Katherine; Allison, David; Osman, Mahamed; Williams, Mallory; Zelenock, Gerald B.

    2014-01-01

    62 year old Caucasian female with pancreatic head mass abutting the superior mesenteric vein (SMV) presented with fine needle aspiration biopsy confirmed diagnosis of ductal adenocarcinoma. CT scan showed near complete obstruction of portal vein and large SMV collateral development. After 3 months of neoadjuvant therapy, her portal vein flow improved significantly, SMV collateral circulation was diminished. Pancreaticoduodenectomy (PD) and superior mesenteric portal vein (SMPV) confluence resection were performed; A saphenous vein interposition graft thrombosed immediately. The splenic vein remnant was distended and adjacent to the stump of the portal vein. Harvesting an internal jugular vein graft required extra time and using a synthetic graft posed a risk of graft thrombosis or infection. As a result, we chose to perform a direct anastomosis of the portal and splenic vein in a desperate situation. The anastomosis decompressed the mesenteric venous system, so we then ligated the SMV. The patient had an uneventful postoperative course, except transient ascites. She redeveloped ascites more than one year later. At that time a PET scan showed bilateral lung and right femur metastatic disease. She expired 15 months after PD. Conclusion The lessons we learned are (1) Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2) Synthetic graft is an alternative for internal jugular vein graft. (3) Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4) It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival. PMID:25568802

  1. Effects of Nuclear Factor-E2-related factor 2/Heme Oxygenase 1 on splanchnic hemodynamics in experimental cirrhosis with portal hypertension.

    Science.gov (United States)

    Qin, Jun; He, Yue; Duan, Ming; Luo, Meng

    2017-05-01

    We explored the effects of Nuclear Factor-E2-related factor 2 (Nrf2) and Heme Oxygenase 1 (HO-1) on splanchnic hemodynamics in portal hypertensive rats. Experimental cirrhosis with portal hypertension was induced by intraperitoneal injection of carbon tetrachloride. The expression of proteins was examined by immunoblotting. Hemodynamic studies were performed by radioactive microspheres. The vascular perfusion system was used to measure the contractile response of mesentery arterioles in rats. Nrf2 expression in the nucleus and HO-1 expression in cytoplasm was significantly enhanced in portal hypertensive rats. Portal pressure, as well as regional blood flow, increased significantly in portal hypertension and can be blocked by tin protoporphyrin IX. The expression of endogenous nitric oxide synthase and vascular endothelial growth factors increased significantly compared to normal rats, while HO-1 inhibition decreased the expression of these proteins significantly. The contractile response of mesenteric arteries decreased in portal hypertension, but can be partially recovered through tin protoporphyrin IX treatment. The expression of Nrf2/HO-1 increased in mesenteric arteries of portal hypertensive rats, which was related to oxidative stress. HO-1was involved in increased portal pressure and anomaly splanchnic hemodynamics in portal hypertensive rats. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Altered blood-brain barrier permeability in rats with prehepatic portal hypertension turns to normal when portal pressure is lowered

    Science.gov (United States)

    Eizayaga, Francisco; Scorticati, Camila; Prestifilippo, Juan P; Romay, Salvador; Fernandez, Maria A; Castro, José L; Lemberg, Abraham; Perazzo, Juan C

    2006-01-01

    AIM: To study the blood-brain barrier integrity in prehepatic portal hypertensive rats induced by partial portal vein ligation, at 14 and 40 d after ligation when portal pressure is spontaneously normalized. METHODS: Adult male Wistar rats were divided into four groups: Group I: Sham14d , sham operated; Group II: PH14d , portal vein stenosis; (both groups were used 14 days after surgery); Group III: Sham40d, Sham operated and Group IV: PH40d Portal vein stenosis (Groups II and IV used 40 d after surgery). Plasma ammonia, plasma and cerebrospinal fluid protein and liver enzymes concentrations were determined. Trypan and Evans blue dyes, systemically injected, were investigated in hippocampus to study blood-brain barrier integrity. Portal pressure was periodically recorded. RESULTS: Forty days after stricture, portal pressure was normalized, plasma ammonia was moderately high, and both dyes were absent in central nervous system parenchyma. All other parameters were reestablished. When portal pressure was normalized and ammonia level was lowered, but not normal, the altered integrity of blood-brain barrier becomes reestablished. CONCLUSION: The impairment of blood-brain barrier and subsequent normalization could be a mechanism involved in hepatic encephalopathy reversibility. Hemodynamic changes and ammonia could trigger blood-brain barrier alterations and its reestablishment. PMID:16552803

  3. Enterprise Information Management with Plone Portals

    Directory of Open Access Journals (Sweden)

    Marcello Peixoto Bax

    2009-05-01

    Full Text Available The article shows that it is possible to implement a corporate portal using open source software, in an integrated manner with the proprietary MS Windows environment. As it is the real scenario in the vast majority of businesses and organizations today, a portal that meets these specific requirements is highly representative, mainly because MS Windows integration in the client environment (not in the server is not trivial for an open source portal. The paper shows that, by deploying a portal in this context the company considerably moves forward regarding information management. To show this, the article focuses on the key positive aspects arising from the deployment of a intranet / extranet portal in that context, i.e., MS Windows integration; editing with MS Office or other similar applications; shared editing control (with check-in and check-out; universal web access; and the use of metadata and workflow.

  4. The NUCLEONICA Nuclear Science Portal

    International Nuclear Information System (INIS)

    Magill, Joseph; Dreher, Raymond

    2009-01-01

    NUCLEONICA (www.nucleonica.net) is a new nuclear science web portal which provides a customisable, integrated environment and collaboration platform using the latest internet 'Web 2.0' technology. NUCLEONICA is aimed at professionals, academics and students working in nuclear power, health physics and radiation protection, nuclear and radio-chemistry, and astrophysics. A unique feature of the portal is the wide range of user friendly web-based nuclear science applications. The portal is also ideal for education and training purposes and as a knowledge management platform to preserve nuclear knowledge built up over many decades.

  5. Teen use of a patient portal: a qualitative study of parent and teen attitudes.

    Science.gov (United States)

    Bergman, David A; Brown, Nancy L; Wilson, Sandra

    2008-01-01

    We conducted a qualitative study of the attitudes of teens and parents toward the use of a patient portal. We conducted two teen and two parent focus groups, one teen electronic bulletin board, and one parent electronic bulletin board. Videotapes and transcripts from the groups were independently analyzed by two reviewers for significant themes, which were then validated by two other members of the research team. Twenty-eight teens and 23 parents participated in the groups. Significant themes included issues about teens' control of their own healthcare; enthusiasm about the use of a patient portal to access their providers, seek health information, and make appointments; and concerns about confidentiality. In summary, there was considerable support among teens and parents for a patient portal as well as concerns about confidentiality. The teen portal affords an opportunity to negotiate issues of confidentiality.

  6. Electronic patient portals: evidence on health outcomes, satisfaction, efficiency, and attitudes: a systematic review.

    Science.gov (United States)

    Goldzweig, Caroline Lubick; Orshansky, Greg; Paige, Neil M; Towfigh, Ali Alexander; Haggstrom, David A; Miake-Lye, Isomi; Beroes, Jessica M; Shekelle, Paul G

    2013-11-19

    Patient portals tied to provider electronic health record (EHR) systems are increasingly popular. To systematically review the literature reporting the effect of patient portals on clinical care. PubMed and Web of Science searches from 1 January 1990 to 24 January 2013. Hypothesis-testing or quantitative studies of patient portals tethered to a provider EHR that addressed patient outcomes, satisfaction, adherence, efficiency, utilization, attitudes, and patient characteristics, as well as qualitative studies of barriers or facilitators, were included. Two reviewers independently extracted data and addressed discrepancies through consensus discussion. From 6508 titles, 14 randomized, controlled trials; 21 observational, hypothesis-testing studies; 5 quantitative, descriptive studies; and 6 qualitative studies were included. Evidence is mixed about the effect of portals on patient outcomes and satisfaction, although they may be more effective when used with case management. The effect of portals on utilization and efficiency is unclear, although patient race and ethnicity, education level or literacy, and degree of comorbid conditions may influence use. Limited data for most outcomes and an absence of reporting on organizational and provider context and implementation processes. Evidence that patient portals improve health outcomes, cost, or utilization is insufficient. Patient attitudes are generally positive, but more widespread use may require efforts to overcome racial, ethnic, and literacy barriers. Portals represent a new technology with benefits that are still unclear. Better understanding requires studies that include details about context, implementation factors, and cost.

  7. Portal vein thrombosis in children and adolescents: 20 years experience of a pediatric hepatology reference center

    Directory of Open Access Journals (Sweden)

    Priscila Menezes Ferri

    2012-03-01

    Full Text Available CONTEXT: Portal vein thrombosis refers to a total or partial obstruction of the blood flow in this vein due to a thrombus formation. It is an important cause of portal hypertension in the pediatric age group with high morbidity rates due to its main complication - the upper gastrointestinal bleeding. OBJECTIVE: To describe a group of patients with portal vein thrombosis without associated hepatic disease of the Pediatric Hepatology Clinic of the Hospital das Clínicas, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil with emphasis on diagnosis, presentation form and clinical complications, and the treatment of portal hypertension. METHODS: This is a descriptive study of a series of children and adolescents cases assisted from January 1990 to December 2010. The portal vein thrombosis diagnosis was established by ultrasound. RESULTS: Of the 55 studied patients, 30 (54.5% were male. In 29 patients (52.7%, none of the risk factors for portal vein thrombosis was observed. The predominant form of presentation was the upper gastrointestinal bleeding (52.7%. In 20 patients (36.4%, the initial manifestation was splenomegaly. During the whole following period of the study, 39 patients (70.9% showed at least one episode of upper gastrointestinal bleeding. The mean age of patients in the first episode was 4.6 ± 3.4 years old. The endoscopic procedure carried out in the urgency or electively for search of esophageal varices showed its presence in 84.9% of the evaluated patients. The prophylactic endoscopic treatment was performed with endoscopic band ligation of varices in 31.3% of patients. Only one died due to refractory bleeding. CONCLUSIONS: The portal vein thrombosis is one of the most important causes of upper gastrointestinal bleeding in children. In all non febrile children with splenomegaly and/or hematemesis and without hepatomegaly and with normal hepatic function tests, it should be suspect of portal vein thrombosis. Thus, an

  8. Effect of portal hypertension and duct ligature on pancreatic fluid pressures in cats

    DEFF Research Database (Denmark)

    Ebbehøj, N; Borly, L; Heyeraas, K J

    1990-01-01

    measured before and after acutely induced portal hypertension; in the other group of cats the pressures were measured after an overnight ligature of the pancreatic main duct. At rest the needle pressure was equal to duct pressure but significantly lower than interstitial fluid pressure and portal pressure...

  9. Evaluation of the formation of esophageal varices by per-rectal portal scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Ikeoka, Naoko; Monna, Takeyuki; Shiomi, Susumu; Kuroki, Tetsuo; Kobayashi, Kenzo; Ochi, Hironobu; Onoyama, Yasuto (Osaka City Univ. (Japan). Faculty of Medicine); Yamamoto, Sukeo

    1989-12-01

    Portal circulation in patients with liver diseases was evaluated by {sup 99m}Tc-pertechnetate per-rectal portal scintigraphy, and we retrospectively examined the relationship between the extent of abnormality in the portal circulation and the development of esophageal varices. The per-rectal portal shunt index (PRPSI) was calculated for 13 healthy subjects and 79 patients with chronic hepatitis and 214 with cirrhosis of the liver. In the healthy subjects, the mean PRPSI was 4.8%. In the patients with hepatitis, the mean PRPSI was 8.4%, and in the patients with cirrhosis, it was 48.5%. The PRPSI was significantly higher in the cirrhotic patients with esophageal varices than in those without it, and also in the cirrhotic patients with encephalopathy than in those without it. The cumulative incidence of esophageal varices in the 3 years of the study in patients whose PRPSI was 20% or over was significantly higher than that in patients whose PRPSI was under 20%. The results suggested that this non-invasive method should be useful for predictions of the formation of esophageal varices. (author).

  10. Evaluation of the formation of esophageal varices by per-rectal portal scintigraphy

    International Nuclear Information System (INIS)

    Ikeoka, Naoko; Monna, Takeyuki; Shiomi, Susumu; Kuroki, Tetsuo; Kobayashi, Kenzo; Ochi, Hironobu; Onoyama, Yasuto; Yamamoto, Sukeo.

    1989-01-01

    Portal circulation in patients with liver diseases was evaluated by 99m Tc-pertechnetate per-rectal portal scintigraphy, and we retrospectively examined the relationship between the extent of abnormality in the portal circulation and the development of esophageal varices. The per-rectal portal shunt index (PRPSI) was calculated for 13 healthy subjects and 79 patients with chronic hepatitis and 214 with cirrhosis of the liver. In the healthy subjects, the mean PRPSI was 4.8%. In the patients with hepatitis, the mean PRPSI was 8.4%, and in the patients with cirrhosis, it was 48.5%. The PRPSI was significantly higher in the cirrhotic patients with esophageal varices than in those without it, and also in the cirrhotic patients with encephalopathy than in those without it. The cumulative incidence of esophageal varices in the 3 years of the study in patients whose PRPSI was 20% or over was significantly higher than that in patients whose PRPSI was under 20%. The results suggested that this non-invasive method should be useful for predictions of the formation of esophageal varices. (author)

  11. [Hepatic transit times and liver elasticity compared with meld in predicting a 1 year adverse clinical outcome of a clinically diagnosed cirrhosis].

    Science.gov (United States)

    Koller, Tomáš; Piešťanská, Zuzana; Hlavatý, Tibor; Holomáň, Jozef; Glasa, Jozef; Payer, Juraj

    Hepatic transit times measured by the contrast enhanced ultrasonography and liver elasticity were found to predict a clinically significant portal hypertension. However, these modalities we not yet sufficiently evaluated in predicting adverse clinical outcome in patients with clinically diagnosed cirrhosis (D´Amico stages > 1), having a clinically significant portal hypertension. The aim of our study was to assess the predictive power of the liver transit times and the liver elasticity on an adverse clinical outcome of clinically diagnosed cirrhosis compared with the MELD score. The study group included 48 consecutive outpatients with cirrhosis in the 2., 3. and 4. DAmico stages. Patients with stage 4 could have jaundice, patients with other complications of portal hypertension were excluded. Transit times were measured from the time of intravenous administration of contrast agent (Sonovue) to a signal appearance in a hepatic vein (hepatic vein arrival time, HVAT) or time difference between the contrast signal in the hepatic artery and hepatic vein (hepatic transit time, HTT) in seconds. Elasticity was measured using the transient elastography (Fibroscan). The transit times and elasticity were measured at baseline and patients were followed for up for 1 year. Adverse outcome of cirrhosis was defined as the appearance of clinically apparent ascites and/or hospitalization for liver disease and/or death within 1 year. The mean age was 61 years, with female/male ratio 23/25. At baseline, the median Child-Pugh score was 5 (IQR 5.0-6.0), MELD 9.5 (IQR 7.6 to 12.1), median HVAT was 22 s (IQR 19-25) and HTT 6 (IQR 5-9). HTT and HVAT negatively correlated with Child-Pugh (-0.351 and -0.441, p = 0.002) and MELD (-0.479 and -0.388, p = 0.006) scores. The adverse outcome at 1-year was observed in 11 cases (22.9 %), including 6 deaths and 5 hospitalizations. Median HVAT in those with/without the adverse outcome was 20 seconds (IQR 19.3-23.5) compared with 22 s (IQR 19-26, p

  12. Portal cholangiopathy: case report

    Directory of Open Access Journals (Sweden)

    Maria Cecilia Almeida Maia

    2014-01-01

    Full Text Available The present report describes the case of a child that after blunt abdominal trauma presented with portal thrombosis followed by progressive splenomegaly and jaundice. Ultrasonography and percutaneous cholangiography revealed biliary dilatation secondary to choledochal stenosis caused by dilated peribiliary veins, characterizing a case of portal biliopathy. The present case report is aimed at presenting an uncommon cause of this condition.

  13. Some thoughts to realignment of PortalU

    International Nuclear Information System (INIS)

    Konstantinidis, Stefanie; Kruse, Fred

    2013-01-01

    Environmental information is the basis for improving the environmental situation in the EU. The challenge poses the tailoring of information to a defined group of interest and not only the technical possibility to retrieve the environmental information. Even though, the technical infrastructure for retrieving public environmental information is the first step. Hence, the clear understanding of the needs of the general public is essential for a successful environmental information portal for the interest group ''general public''. What does this mean referring to the German Environmental Information Portal PortalU? Since the launch of PortalU the focus of the portal is set on making available official environmental information especially on German Federal Republic and Federal States level. Currently, information from web pages represents the greatest amount of information. In contrast, information from environmental data catalogs and further data bases represent a smaller amount of information within PortalU. But quantity itself does not tell anything about the demand of a target group. The experience of the last years has shown that environmental interested citizens use mainly general search engines like Google to find information from public environmental web pages. Thus it would be worth thinking about a realignment of PortalU. The idea of a prospective alignment of PortalU is to concentrate on important environmental information, which is not easily found via Google and other general search engines. This information is mainly provided via environmental data catalogs and possibly further data bases. Some thoughts about the potential form and design of a respectively aligned environmental portal are discussed in the paper. (orig.)

  14. arXiv Dipole portal to heavy neutral leptons

    CERN Document Server

    Magill, Gabriel; Pospelov, Maxim; Tsai, Yu-Dai

    We consider generic neutrino dipole portals between left-handed neutrinos, photons, and right-handed heavy neutral leptons (HNL) with Dirac masses. The dominance of this portal significantly alters the conventional phenomenology of HNLs. We derive a comprehensive set of constraints on the dipole portal to HNLs by utilizing data from LEP, LHC, MiniBooNE, LSND as well as observations of Supernova 1987A and consistency of the standard Big Bang Nucleosynthesis. We calculate projected sensitivities from the proposed high-intensity SHiP beam dump experiment, and the ongoing experiments at the Short-Baseline Neutrino facility at Fermilab. Dipole mediated Primakoff neutrino upscattering and Dalitz-like meson decays are found to be the main production mechanisms in most of the parametric regime under consideration. Proposed explanations of LSND and MiniBooNE anomalies based on HNLs with dipole-induced decays are found to be severely constrained, or to be tested in the future experiments.

  15. Glutamine synthetase activity and glutamate uptake in hippocampus and frontal cortex in portal hypertensive rats

    Science.gov (United States)

    Acosta, Gabriela Beatriz; Fernández, María Alejandra; Roselló, Diego Martín; Tomaro, María Luján; Balestrasse, Karina; Lemberg, Abraham

    2009-01-01

    AIM: To study glutamine synthetase (GS) activity and glutamate uptake in the hippocampus and frontal cortex (FC) from rats with prehepatic portal vein hypertension. METHODS: Male Wistar rats were divided into sham-operated group and a portal hypertension (PH) group with a regulated stricture of the portal vein. Animals were sacrificed by decapitation 14 d after portal vein stricture. GS activity was determined in the hippocampus and FC. Specific uptake of radiolabeled L-glutamate was studied using synaptosome-enriched fractions that were freshly prepared from both brain areas. RESULTS: We observed that the activity of GS increased in the hippocampus of PH rats, as compared to control animals, and decreased in the FC. A significant decrease in glutamate uptake was found in both brain areas, and was more marked in the hippocampus. The decrease in glutamate uptake might have been caused by a deficient transport function, significantly and persistent increase in this excitatory neurotransmitter activity. CONCLUSION: The presence of moderate ammonia blood levels may add to the toxicity of excitotoxic glutamate in the brain, which causes alterations in brain function. Portal vein stricture that causes portal hypertension modifies the normal function in some brain regions. PMID:19533812

  16. Avaliação intra-operatória da pressão portal e resultados imediatos do tratamento cirúrgico da hipertensão portal em pacientes esquistossomóticos submetidos a desconexão ázigo-portal e esplenectomia Intra-operative evaluation of portal pressure and immediate results of surgical treatment of portal hypertension in schistosomotic patients submitted to esophagogastric devascularization with splenectomy

    Directory of Open Access Journals (Sweden)

    Walter De Biase da Silva-Neto

    2004-09-01

    showed a statistically significant reduction in their size, when compared to the pre-surgical measurements. CONCLUSION: These results have demonstrated that the esophagogastric devascularization with splenectomy promotes immediate decrease in the portal pressure and a consequent reduction in the esophageal varices size. We also observed that the risk of mortality and severe complications related to this technique is not insignificant.

  17. Presentation of Austrians recommended dispersion model for tunnel portals

    Energy Technology Data Exchange (ETDEWEB)

    Oettl, D.; Sturm, P.; Almbauer, R. [Inst. for Internal Combustion Engines and Thermodynamics, Graz Univ. of Technology (Austria)

    2004-07-01

    Street tunnels in cities are often suggested as solution to avoid daily congestions but also to prevent residential areas from high noise and air pollution emissions. In case of longitudinal ventilated tunnels high pollution levels may occur in the vicinity of the portals. The dispersion of pollutants from tunnel portals is considered to differ significantly from those of other sources, such as line or point sources. To the best of the authors knowledge, there exist currently two distinct dispersion models, which are especially designed to treat dispersion from tunnel portals. Okamoto et al proposed a diagnostic wind field model, where the dispersion is modelled using a Taylor-Galerkin-Forester filter method. Oettl et al. developed a Lagrangian-type model (GRAL TM 3.5=Graz Lagrangian model Tunnel Module version 3.5), which is briefly described in the next section. (orig.)

  18. Lunar and Vesta Web Portals

    Science.gov (United States)

    Law, E.; JPL Luna Mapping; Modeling Project Team

    2015-06-01

    The Lunar Mapping and Modeling Project offers Lunar Mapping and Modeling Portal (http://lmmp.nasa.gov) and Vesta Trek Portal (http://vestatrek.jpl.nasa.gov) providing interactive visualization and analysis tools to enable users to access mapped Lunar and Vesta data products.

  19. Analgesic control after hip arthroscopy: a randomised, double-blinded trial comparing portal with intra-articular infiltration of bupivacaine.

    LENUS (Irish Health Repository)

    Baker, Joseph F

    2011-06-07

    Abstract: The optimum anaesthetic and analgesic management following hip arthroscopy is yet to be determined. There is, in addition, some concern over the use of intraarticular local anaesthetic. We compared the analgesic efficacy of intra-articular infiltration compared with portal infiltration of bupivacaine following hip arthroscopy. Patients were randomised to receive either 10ml of 0.25% bupivacaine either into the joint or around the portal sites following completion of surgery. 73 patients were recruited (40 intra-articular). The portal infiltration group required significantly more rescue analgesia immediately after surgery (2.33mg vs.0.57mg, p=0.036). Visual Analogue Scale pain scores were not significantly different at 1 and 2 hours following surgery, but at 6 hours the portal group had significantly lower VAS scores (p=0.0036). We believe that the initial pain following surgery results from capsular injury and this explains the need for more rescue analgesia in the portal infiltration group. Further work is needed to establish the ideal regimen. A combination of portal and intra-articular infiltration may be the most efficacious.

  20. Electronic Health Record Portal Adoption: a cross country analysis.

    Science.gov (United States)

    Tavares, Jorge; Oliveira, Tiago

    2017-07-05

    This study's goal is to understand the factors that drive individuals to adopt Electronic Health Record (EHR) portals and to estimate if there are differences between countries with different healthcare models. We applied a new adoption model using as a starting point the extended Unified Theory of Acceptance and Use of Technology (UTAUT2) by incorporating the Concern for Information Privacy (CFIP) framework. To evaluate the research model we used the partial least squares (PLS) - structural equation modelling (SEM) approach. An online questionnaire was administrated in the United States (US) and Europe (Portugal). We collected 597 valid responses. The statistically significant factors of behavioural intention are performance expectancy ([Formula: see text] total  = 0.285; P expectancy ([Formula: see text] total  = 0.160; P value ([Formula: see text] total  = 0.152; P value are only predictors in the US group. The model explained 53% of the variance in behavioural intention and 36% of the variance in use behaviour. Our study identified critical factors for the adoption of EHR portals and significant differences between the countries. Confidentiality issues do not seem to influence acceptance. The EHR portals usage patterns are significantly higher in US compared to Portugal.

  1. Asymptomatic bacteriuria. Clinical significance and management.

    Science.gov (United States)

    Raz, Raul

    2003-10-01

    The clinical significance and management of asymptomatic bacteriuria (ASB) differs according to different groups of patients. ASB requires antibiotic treatment in pregnant women, children aged 5-6 years and prior to invasive genitourinary procedures. However, there is a consensus that ASB in the elderly, healthy school girls and young women, diabetic women and patients with indwelling catheters or intermittent catheterization has no clinical significance and antibiotic prescription is not indicated.

  2. Developing patient portals in a fragmented healthcare system.

    Science.gov (United States)

    Otte-Trojel, Terese; de Bont, Antoinette; Aspria, Marcello; Adams, Samantha; Rundall, Thomas G; van de Klundert, Joris; de Mul, Marleen

    2015-10-01

    Use of patient portals may contribute to improved patient health and experiences and better organizational performance. In the Netherlands, patient portals have gained considerable attention in recent years, as evidenced by various policy initiatives and practical efforts directed at developing portals. Due to the fragmented setup of the Dutch healthcare system patient portals that give patients access to information and services from across their providers are developed in inter-organizational collaboration. The objective of this paper is to identify and describe the types of collaborations, or networks, that have been established to develop patient portals in the Netherlands. Understanding the characteristics of these networks as well as the development of their respective portals enables us to assess the enabling and constraining effects of different network types on patient portal initiatives. We used qualitative methods including interview and documents analysis. In a first step, we interviewed eighteen experts and reviewed relevant national policy and strategy documents. Based on this orientation, we selected three networks we deemed to be representative of inter-organizational efforts to develop Dutch patient portals in 2012. In a second step, we interviewed twelve representatives of these patient portal networks and collected documents related to the portals. We applied content analytic techniques to analyze data from the three cases. The three studied networks differed in their number and diversity of actors, the degree to which these actors were mutually dependent, the degree to which network governance was decentralized, and the dynamics of the network structures. We observed that the portals developed in networks displaying the highest degree of these characteristics experienced most difficulties associated with developing patient portals - such as achieving interoperability, successful implementation, regulatory complaisance, and financial

  3. von Willebrand factor as a novel noninvasive predictor of portal hypertension and esophageal varices in hepatitis B patients with cirrhosis.

    Science.gov (United States)

    Wu, Hao; Yan, Shiping; Wang, Guangchuan; Cui, Shaobo; Zhang, Chunqing; Zhu, Qiang

    2015-01-01

    At present, there is no perfect noninvasive method to assess portal hypertension and esophageal varices. Early predicting esophageal varices can provide evidence for managing cirrhotic patients. We aimed to further investigate von Willebrand factor (vWF) as a noninvasive predictor of portal hypertension, especially of esophageal varices. A total of 60 hepatitis B patients with cirrhosis and 45 healthy subjects were enrolled in this study. Levels of six markers were examined. All patients underwent hepatic venous pressure gradient (HVPG) and esophagogastroduodenoscopy. We evaluated the performance of six factors for diagnosis of portal hypertension and esophageal varices. The vWF levels in liver tissues were observed by immunohistochemistry. Correlations between the level of vWF in liver tissues and HVPG and between levels of vWF in tissues and plasma were examined. Cutoff values of plasma vWF (1510.5 mU/mL and 1701 mU/mL) showed high positive predictive value (PPV, 90.2% and 87.5%) in predicting clinically significant portal hypertension and severe portal hypertension. Cutoff values of vWF (1414 mU/ml and 1990 mU/mL, PPV 90.3% and 86.3%, respectively) were provided to detect the presence and degree of esophageal varices. Linear correlations were observed between levels of vWF in liver tissues and HVPG (r(2) = 0.552, p portal hypertension and esophageal varices in hepatitis B patients with cirrhosis. Increased levels of vWF in liver tissues may induce the elevated plasma vWF levels, but molecular mechanism is needed for further study.

  4. Research advances in computed tomography and magnetic resonance imaging findings of cirrhotic portal hypertension

    Directory of Open Access Journals (Sweden)

    YAN Fuhua

    2016-06-01

    Full Text Available Portal hypertension is the most common complication of liver cirrhosis. Noninvasive radiological examinations have important values in evaluating liver parenchyma, collateral circulation, and esophagogastric variceal bleeding in liver cirrhosis. Computed tomography (CT and magnetic resonance imaging (MRI can reflect the changes in liver morphology, the density and signals of liver parenchyma, and hemodynamics and have important values in disease diagnosis and prognostic evaluation. CT and functional MRI, such as perfusion-weighted imaging, MR elastography, and MR diffusion-weighted imaging, can provide quantitative information and can be applied in the diagnosis of hepatic fibrosis and early-stage liver cirrhosis in clinical practice. CT angiography and MR angiography, especially unenhanced MR angiography, can show the condition of the branches of portal vein, which helps to evaluate the risk of esophagogastric variceal bleeding and detect the markers for early warning. A combination of CT and MRI and evaluation of their potential in clinical application can give full play to the role of radiological examinations in the diagnosis, evaluation, and prognostic analysis of cirrhotic portal hypertension.

  5. Liferay Portal Systems Development

    CERN Document Server

    Yuan, Jonas X

    2012-01-01

    This book focuses on teaching by example. Every chapter provides an overview, and then dives right into hands-on examples so you can see and play with the solution in your own environment. This book is for Java developers who don't need any prior experience with Liferay portal. Although Liferay portal makes heavy use of open source frameworks, no prior experience of using these is assumed.

  6. Some thoughts to realignment of PortalU

    Energy Technology Data Exchange (ETDEWEB)

    Konstantinidis, Stefanie; Kruse, Fred [Lower Saxony Ministry of Environment and Climate Protection, Hannover (Germany). Coordination Centre PortalU

    2013-07-01

    Environmental information is the basis for improving the environmental situation in the EU. The challenge poses the tailoring of information to a defined group of interest and not only the technical possibility to retrieve the environmental information. Even though, the technical infrastructure for retrieving public environmental information is the first step. Hence, the clear understanding of the needs of the general public is essential for a successful environmental information portal for the interest group ''general public''. What does this mean referring to the German Environmental Information Portal PortalU? Since the launch of PortalU the focus of the portal is set on making available official environmental information especially on German Federal Republic and Federal States level. Currently, information from web pages represents the greatest amount of information. In contrast, information from environmental data catalogs and further data bases represent a smaller amount of information within PortalU. But quantity itself does not tell anything about the demand of a target group. The experience of the last years has shown that environmental interested citizens use mainly general search engines like Google to find information from public environmental web pages. Thus it would be worth thinking about a realignment of PortalU. The idea of a prospective alignment of PortalU is to concentrate on important environmental information, which is not easily found via Google and other general search engines. This information is mainly provided via environmental data catalogs and possibly further data bases. Some thoughts about the potential form and design of a respectively aligned environmental portal are discussed in the paper. (orig.)

  7. A View on Electronic Learning Portals

    OpenAIRE

    Zavaraqi, Rasoul

    2009-01-01

    Portals are less than a decade old. They have come to cover are areas of electronic services, including electronic learning. With their efficient communication and information capabilities, these portals are capable of realizing novel learning concepts such as structuralism, active and cooperative learning. The present paper endeavors to discuss the latest understanding, theories and concepts regarding E-learning portals and to review the issues and steps that should be considered in designin...

  8. ESTERR-PRO: A Setup Verification Software System Using Electronic Portal Imaging

    Directory of Open Access Journals (Sweden)

    Pantelis A. Asvestas

    2007-01-01

    Full Text Available The purpose of the paper is to present and evaluate the performance of a new software-based registration system for patient setup verification, during radiotherapy, using electronic portal images. The estimation of setup errors, using the proposed system, can be accomplished by means of two alternate registration methods. (a The portal image of the current fraction of the treatment is registered directly with the reference image (digitally reconstructed radiograph (DRR or simulator image using a modified manual technique. (b The portal image of the current fraction of the treatment is registered with the portal image of the first fraction of the treatment (reference portal image by applying a nearly automated technique based on self-organizing maps, whereas the reference portal has already been registered with a DRR or a simulator image. The proposed system was tested on phantom data and on data from six patients. The root mean square error (RMSE of the setup estimates was 0.8±0.3 (mean value ± standard deviation for the phantom data and 0.3±0.3 for the patient data, respectively, by applying the two methodologies. Furthermore, statistical analysis by means of the Wilcoxon nonparametric signed test showed that the results that were obtained by the two methods did not differ significantly (P value >0.05.

  9. Portosystemic shunting in portal hypertension: evaluation with portal scintigraphy with transrectally administered I-123 IMP

    International Nuclear Information System (INIS)

    Kashiwagi, T.; Azuma, M.; Ikawa, T.; Takehara, T.; Matsuda, H.; Yoshioka, H.; Mitsutani, N.; Koizumi, T.; Kimura, K.

    1988-01-01

    Portosystemic shunting was evaluated with rectal administration of iodine-123 iodoamphetamine (IMP) in seven patients without liver disease and 53 patients with liver cirrhosis. IMP (2-3 mCi [74-111 MBq]) was administered to the rectum through a catheter. Images of the chest and abdomen were obtained for up to 60 minutes with a scintillation camera interfaced with a computer. In all patients, images of the liver and/or lungs were observed within 5-10 minutes and became clear with time. In patients without liver disease, only liver images could be obtained, whereas the lung was visualized with or without the liver in all patients with liver cirrhosis. The portosystemic shunt index was calculated by dividing counts of lungs by counts of liver and lung. These values were significantly higher in liver cirrhosis, especially in the decompensated stage. Transrectal portal scintigraphy with IMP appears to be a useful method for noninvasive and quantitative evaluation of portosystemic shunting in portal hypertension

  10. Customizable scientific web portal for fusion research

    International Nuclear Information System (INIS)

    Abla, G.; Kim, E.N.; Schissel, D.P.; Flanagan, S.M.

    2010-01-01

    Web browsers have become a major application interface for participating in scientific experiments such as those in magnetic fusion. The recent advances in web technologies motivated the deployment of interactive web applications with rich features. In the scientific world, web applications have been deployed in portal environments. When used in a scientific research environment, such as fusion experiments, web portals can present diverse sources of information in a unified interface. However, the design and development of a scientific web portal has its own challenges. One such challenge is that a web portal needs to be fast and interactive despite the high volume of information and number of tools it presents. Another challenge is that the visual output of the web portal must not be overwhelming to the end users, despite the high volume of data generated by fusion experiments. Therefore, the applications and information should be customizable depending on the needs of end users. In order to meet these challenges, the design and implementation of a web portal needs to support high interactivity and user customization. A web portal has been designed to support the experimental activities of DIII-D researchers worldwide by providing multiple services, such as real-time experiment status monitoring, diagnostic data access and interactive data visualization. The web portal also supports interactive collaborations by providing a collaborative logbook, shared visualization and online instant messaging services. The portal's design utilizes the multi-tier software architecture and has been implemented utilizing web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services, which allows users to create a unique, personalized working environment to fit their own needs and interests. This paper describes the software

  11. Customizable scientific web portal for fusion research

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G., E-mail: abla@fusion.gat.co [General Atomics, P.O. Box 85608, San Diego, CA (United States); Kim, E.N.; Schissel, D.P.; Flanagan, S.M. [General Atomics, P.O. Box 85608, San Diego, CA (United States)

    2010-07-15

    Web browsers have become a major application interface for participating in scientific experiments such as those in magnetic fusion. The recent advances in web technologies motivated the deployment of interactive web applications with rich features. In the scientific world, web applications have been deployed in portal environments. When used in a scientific research environment, such as fusion experiments, web portals can present diverse sources of information in a unified interface. However, the design and development of a scientific web portal has its own challenges. One such challenge is that a web portal needs to be fast and interactive despite the high volume of information and number of tools it presents. Another challenge is that the visual output of the web portal must not be overwhelming to the end users, despite the high volume of data generated by fusion experiments. Therefore, the applications and information should be customizable depending on the needs of end users. In order to meet these challenges, the design and implementation of a web portal needs to support high interactivity and user customization. A web portal has been designed to support the experimental activities of DIII-D researchers worldwide by providing multiple services, such as real-time experiment status monitoring, diagnostic data access and interactive data visualization. The web portal also supports interactive collaborations by providing a collaborative logbook, shared visualization and online instant messaging services. The portal's design utilizes the multi-tier software architecture and has been implemented utilizing web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services, which allows users to create a unique, personalized working environment to fit their own needs and interests. This paper describes the software

  12. Customizable Scientific Web Portal for Fusion Research

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G; Kim, E; Schissel, D; Flannagan, S [General Atomics, San Diego (United States)

    2009-07-01

    The Web browser has become one of the major application interfaces for remotely participating in magnetic fusion experiments. Recently in other areas, web portals have begun to be deployed. These portals are used to present very diverse sources of information in a unified way. While a web portal has several benefits over other software interfaces, such as providing single point of access for multiple computational services, and eliminating the need for client software installation, the design and development of a web portal has unique challenges. One of the challenges is that a web portal needs to be fast and interactive despite a high volume of tools and information that it presents. Another challenge is the visual output on the web portal often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments; therefore the applications and information should be customizable depending on the needs of users. An appropriate software architecture and web technologies can meet these problems. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It utilizes a multi-tier software architecture, and web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services for users to select. The users can create a unique personalized working environment to fit their own needs and interests. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, shared visualization and online instant message services. Furthermore, the web portal will provide a mechanism to allow users to create their own applications on the web portal as well as bridging capabilities to external applications such as

  13. Customisable Scientific Web Portal for Fusion Research

    Energy Technology Data Exchange (ETDEWEB)

    Abla, G; Kim, E; Schissel, D; Flannagan, S [General Atomics, San Diego (United States)

    2009-07-01

    The Web browser has become one of the major application interfaces for remotely participating in magnetic fusion. Web portals are used to present very diverse sources of information in a unified way. While a web portal has several benefits over other software interfaces, such as providing single point of access for multiple computational services, and eliminating the need for client software installation, the design and development of a web portal has unique challenges. One of the challenges is that a web portal needs to be fast and interactive despite a high volume of tools and information that it presents. Another challenge is the visual output on the web portal often is overwhelming due to the high volume of data generated by complex scientific instruments and experiments; therefore the applications and information should be customizable depending on the needs of users. An appropriate software architecture and web technologies can meet these problems. A web-portal has been designed to support the experimental activities of DIII-D researchers worldwide. It utilizes a multi-tier software architecture, and web 2.0 technologies, such as AJAX, Django, and Memcached, to develop a highly interactive and customizable user interface. It offers a customizable interface with personalized page layouts and list of services for users to select. Customizable services are: real-time experiment status monitoring, diagnostic data access, interactive data visualization. The web-portal also supports interactive collaborations by providing collaborative logbook, shared visualization and online instant message services. Furthermore, the web portal will provide a mechanism to allow users to create their own applications on the web portal as well as bridging capabilities to external applications such as Twitter and other social networks. In this series of slides, we describe the software architecture of this scientific web portal and our experiences in utilizing web 2.0 technologies. A

  14. [Current clinical significance of anaerobic bacteremia].

    Science.gov (United States)

    Jirsa, Roman; Marešová, Veronika; Brož, Zdeněk

    2010-10-01

    to estimate tje current clinical significance of anaerobic bacteremia in a group of Czech hospitals. this retrospective analysis comprised 8 444 anaerobic blood cultures in patients admitted to four Czech hospitals between 2004 and 2007. in 16 patients, blood cultures yielded significant anaerobic bacteria. Thus, anaerobic bacteremia accounted for less than 2 % of clinically significant bacteremia. Four patients (18 %) died but none of the deaths could be clearly attributable to anaerobic bacteria in the bloodstream. The most common comorbidities predisposing to anaerobic bacteremia and the most frequent sources of infection were similar to those reported by other authors. The majority of anaerobic bacteremia cases were due to gram-negative bacteria, followed by Clostridium perfringens and, surprisingly, Eubacterium spp. (particularly Eubacterium lentum). anaerobic bacteremia remains rare. The comparison of our data with those by other authors suggests that (despite the reported high mortality) the actual clinical significance of anaerobic bacteremia is rather controversial and that the anaerobic bacteremia might not correspond to more serious pathogenic role of the anaerobic bacteria as the source of infection.

  15. Portal dosimetry in wedged beams

    NARCIS (Netherlands)

    Spreeuw, Hanno; Rozendaal, Roel; Camargo, Priscilla; Mans, Anton; Wendling, Markus; Olaciregui-Ruiz, Igor; Sonke, Jan-Jakob; van Herk, Marcel; Mijnheer, Ben

    2015-01-01

    Portal dosimetry using electronic portal imaging devices (EPIDs) is often applied to verify high-energy photon beam treatments. Due to the change in photon energy spectrum, the resulting dose values are, however, not very accurate in the case of wedged beams if the pixel-to-dose conversion for the

  16. Benign hepatic portal venous gas following caustic ingestion

    International Nuclear Information System (INIS)

    Lewin, Maite; Tubiana, Jean-Michel; Pocard, Marc; Caplin, Scott; Parc, Rolland; Blain, Antoine

    2002-01-01

    Hepatic portal vein gas has been documented in numerous conditions and is traditionally regarded as a poor prognostic sign. There are, however, several reports of portal vein gas with a benign course. We report the first case of transient hepatic portal vein gas secondary to the ingestion of a caustic substance. The literature of hepatic portal vein gas in benign disease is reviewed. (orig.)

  17. Reasons and barriers for using a patient portal: survey among patients with diabetes mellitus.

    Science.gov (United States)

    Ronda, Maaike C M; Dijkhorst-Oei, Lioe-Ting; Rutten, Guy E H M

    2014-11-25

    The use of a Web portal for patients with diabetes mellitus to access their own personal health record may result in improved diabetes outcomes. However, the adoption by patients is slow. This may be caused by patient characteristics, but also by the content, layout, and promotion of the portal. Detailed knowledge about this could help increase patients' participation in Web portals. The aim was to study the opinions of patients with diabetes and identify perceived barriers to using a Web portal to optimize its use. We conducted a survey among patients with type 1 and type 2 diabetes mellitus from 62 primary care practices and 1 outpatient hospital clinic in the central area of the Netherlands who all used the same electronic health record with a Web portal. Questionnaires about patient characteristics, opinions about reasons for use or nonuse, and about portal content were sent to 1500 patients with a login and 3000 patients without a login to the Web portal. Patient groups were stratified according to login frequency. Demographic and diabetes-related variables were analyzed with multivariable regression analysis. The total response rate was 66.63% (2391/4399); 1390 of 4399 patients (31.60%) were eligible for analysis. There were 413 regular users (login frequency more than once) and 758 nonusers (no login). Most nonusers (72.4%) stated that the main reason for not requesting a login was that they were unaware of the existence of the portal. Other barriers reported by patients were disinterest in managing their own disease (28.5%, 216/758) and feelings of inadequacy with the use of computers and Internet (11.6%, 88/758). Patients treated by a general practitioner were more frequently nonusers compared to patients treated by an internist (78.8%, 666/846 vs 28.3%, 92/325; Ppatient portal is the main barrier of enrollment. Users and nonusers perceive the usefulness of the portal differently and do not have the same recommendations for additional functionalities. To

  18. Patient portals - An online tool for your health

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000880.htm Patient portals - an online tool for your health To ... is private and secure. What is in a Patient Portal? With a patient portal, you can: Make ...

  19. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    International Nuclear Information System (INIS)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D'Ippolito, Giuseppe; Colleoni, Ramiro

    2008-01-01

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  20. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: ar.leao@uol.com.br; Colleoni, Ramiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Gastroenterologia

    2008-09-15

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  1. Jejunal varices diagnosed by capsule endoscopy in patients with post-liver transplant portal hypertension.

    Science.gov (United States)

    Bass, Lee M; Kim, Stanley; Superina, Riccardo; Mohammad, Saeed

    2017-02-01

    Portal hypertension secondary to portal vein obstruction following liver transplant occurs in 5%-10% of children. Jejunal varices are uncommon in this group. We present a case series of children with significant GI blood loss, negative upper endoscopy, and jejunal varices detected by CE. Case series of patients who had CE for chronic GI blood loss following liver transplantation. Three patients who had their initial transplants at a median age of 7 months were identified at our institution presenting at a median age of 8 years (range 7-16 years) with a median Hgb of 2.8 g/dL (range 1.8-6.8 g/dL). Upper endoscopy was negative for significant esophageal varices, gastric varices, and bleeding portal gastropathy in all three children. All three patients had significant jejunal varices noted on CE in mid-jejunum. Jejunal varices were described as large prominent bluish vessels underneath visualized mucosa, one with evidence of recent bleeding. The results led to venoplasty of the portal vein in two patients and a decompressive shunt in one patient with resolution of GI bleed and anemia. CE is useful to diagnose intestinal varices in children with portal hypertension and GI bleeding following liver transplant. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. GEO portal

    Data.gov (United States)

    US Agency for International Development — The USAID GeoPortal is a new application that groups web-based capabilities for on-demand discovery of and access to geospatial content, services, expertise, and...

  3. Use of NLM medical subject headings with the MeSH2010 thesaurus in the PORTAL-DOORS system.

    Science.gov (United States)

    Taswell, Carl

    2010-01-01

    The NLM MeSH Thesaurus has been incorporated for use in the PORTAL-DOORS System (PDS) for resource metadata management on the semantic web. All 25588 descriptor records from the NLM 2010 MeSH Thesaurus have been exposed as web accessible resources by the PDS MeSH2010 Thesaurus implemented as a PDS PORTAL Registry operating as a RESTful web service. Examples of records from the PDS MeSH2010 PORTAL are demonstrated along with their use by records in other PDS PORTAL Registries that reference the concepts from the MeSH2010 Thesaurus. Use of this important biomedical terminology will greatly enhance the quality of metadata content of other PDS records thus improving cross-domain searches between different problem oriented domains and amongst different clinical specialty fields.

  4. WLCG Operations portal demo tutorial

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    This is a navigation through http://wlcg-ops.web.cern.ch/ the Worldwide LHC Computing Grid (WLCG) Operations' portal. In this portal you will find documentation and information about WLCG Operation activities for: System Administrators at the WLCG sites LHC Experiments Operation coordination people, including Task Forces and Working Groups

  5. Unexpected disappearance of portal cavernoma on long-term anticoagulation.

    Science.gov (United States)

    Silva-Junior, Gilberto; Turon, Fanny; Hernandez-Gea, Virginia; Darnell, Anna; García-Criado, Ángeles; García-Pagán, Juan Carlos

    2014-08-01

    Idiopathic non-cirrhotic portal hypertension is a rare disease of unknown etiology. Patients with idiopathic non-cirrhotic portal hypertension have an increased risk of developing portal vein thrombosis and this is especially prevalent when HIV is also present. We describe a unique case of a patient with idiopathic non-cirrhotic portal hypertension associated to HIV, who developed acute portal vein thrombosis that despite anticoagulation transformed in portal cavernoma and disappeared completely after five years of follow-up on continuous anticoagulation. Copyright © 2014 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  6. User Experience Design in Professional Map-Based Geo-Portals

    Directory of Open Access Journals (Sweden)

    Bastian Zimmer

    2013-10-01

    Full Text Available We have recently been witnessing the growing establishment of map-centered web-based geo-portals on national, regional and local levels. However, a particular issue with these geo-portals is that each instance has been implemented in different ways in terms of design, usability, functionality, interaction possibilities, map size and symbologies. In this paper, we try to tackle these shortcomings by analyzing and formalizing the requirements for map-based geo-portals in a user experience based approach. First, we propose a holistic definition the term of a “geo-portal”. Then, we present our approach to user experience design for map-based geo-portals by defining the functional requirements of a geo-portal, by analyzing previous geo-portal developments, by distilling the results of our empirical user study to perform practically-oriented user requirements, and finally by establishing a set of user experience design guidelines for the creation of map-based geo-portals. These design guidelines have been extracted for each of the main components of a geo-portal, i.e., the map, the search dialogue, the presentation of the search results, symbologies, and other aspects. These guidelines shall constitute the basis for future geo-portal developments to achieve standardization in the user-experience design of map-based geo-portals.

  7. Portal Still Alive and Portal 2: Lessons from Critical Narrative Gaming Pedagogy

    OpenAIRE

    Yamasaki, Lisa Josefina

    2016-01-01

    Due to the increasing popularity of video games in mass media culture, I will be investigating one particular video game series, Portal: Still Alive and Portal 2, and the manner by which players learn from them. After observing that most instructors use these games in physics and math classes, I want to expand more on the way that video games enact a new story-telling feature through experiential means, which also serves a pedagogical function. I assert that players learn from games through...

  8. Combined transjugular intrahepatic portosystemic shunt and other interventions for hepatocellular carcinoma with portal hypertension.

    Science.gov (United States)

    Qiu, Bin; Zhao, Meng-Fei; Yue, Zhen-Dong; Zhao, Hong-Wei; Wang, Lei; Fan, Zhen-Hua; He, Fu-Liang; Dai, Shan; Yao, Jian-Nan; Liu, Fu-Quan

    2015-11-21

    To evaluate combination transjugular intrahepatic portosystemic shunt (TIPS) and other interventions for hepatocellular carcinoma (HCC) and portal hypertension. Two hundred and sixty-one patients with HCC and portal hypertension underwent TIPS combined with other interventional treatments (transarterial chemoembolization/transarterial embolization, radiofrequency ablation, hepatic arterio-portal fistulas embolization, and splenic artery embolization) from January 1997 to January 2010 at Beijing Shijitan Hospital. Two hundred and nine patients (121 male and 88 female, aged 25-69 years, mean 48.3 ± 12.5 years) with complete clinical data were recruited. We evaluated the safety of the procedure (procedure-related death and serious complications), change of portal vein pressure before and after TIPS, symptom relief [e.g., ascites, hydrothorax, esophageal gastric-fundus variceal bleeding (EGVB)], cumulative rates of survival, and distributary channel restenosis. The characteristics of the patients surviving ≥ 5 and portal hypertension symptoms were ameliorated. During the 5 year follow-up, the total recurrence rate of resistant ascites or hydrothorax was 7.2% (15/209); 36.8% (77/209) for EGVB; and 39.2% (82/209) for hepatic encephalopathy. The cumulative rates of distributary channel restenosis at 1, 2, 3, 4, and 5 years were 17.2% (36/209), 29.7% (62/209), 36.8% (77/209), 45.5% (95/209) and 58.4% (122/209), respectively. No procedure-related deaths and serious complications (e.g., abdominal bleeding, hepatic failure, and distant metastasis) occurred. Moreover, Child-Pugh score, portal vein tumor thrombosis, lesion diameter, hepatic arterio-portal fistulas, HCC diagnosed before or after TIPS, stent type, hepatic encephalopathy, and type of other interventional treatments were related to 5 year survival after comparing patient characteristics. TIPS combined with other interventional treatments seems to be safe and efficacious in patients with HCC and portal

  9. False-positive image of portal thrombosis with MRI: portal hypertension as a pitfall. Observation in a Budd-Chiari syndrome

    International Nuclear Information System (INIS)

    Davy-Miallou, C.; Bousquet, J.C.; Bellin, M.F.; Guinet, C.; Grellet, J.

    1990-01-01

    This observation illustrates how difficult it is to interpret the intravascular signal observed with MRI in cases of portal hypertension. A signal occupying the entire lumen of the portal trunk and branches can be seen, which is constantly observed in the axial as well as coronal planes in the 3 series studied. It is hypointense relative to the liver on T1-weighted images, hyperintense on T2-weighted images: this appearance therefore perfectly mimicks portal thrombosis. Ultrasound combined with pulsed Doppler demonstrates the stagnant blood within the patent portal system. This kind of artifact, which is produced by a very slow flow or even by the standstill of flow, is much more difficult to recognize than the common flow artifacts; the criteria put forward by various authors to distinguish between artifacts and thrombosis are of no avail in this case. Examinations must able to confirm or rule out portal thrombosis in the case of portal hypertension with deceleration of flow. In practice, ultrasound studies, combined with pulsed Doppler in the best cases, is therefore indicated as a first-intension technique [fr

  10. Trombose de veia porta em crianças e adolescentes Portal vein thrombosis in children and adolescents

    Directory of Open Access Journals (Sweden)

    Graziela C. M. Schettino

    2006-06-01

    literature of the past 10 years was reviewed using the PubMed and MEDLINE search engines, with major focus on portal vein thrombosis and its clinical outcomes. The following keywords or expressions were used for the web search: portal vein thrombosis, extra-hepatic portal vein obstruction, prognosis, children, portal hypertension, esophagogastric varices. Additionally, we also reviewed the articles cited in the references of the initially selected papers, as well as relevant textbooks. SUMMARY OF THE FINDINGS: Portal vein thrombosis is one of the most common causes of portal hypertension among children. The initial clinical manifestation is characterized either by episodes of upper gastrointestinal bleeding or by splenomegaly on routine clinical examination. The major complications include upper gastrointestinal bleeding, hypersplenism secondary to splenomegaly, growth retardation, and portal biliopathy. The diagnosis is made by abdominal Doppler ultrasonography. Treatment is targeted at the complications and includes primary and secondary prophylaxis against upper gastrointestinal bleeding (which results from the rupture of esophageal varices, and portosystemic shunting in selected cases. CONCLUSIONS: Portal vein thrombosis is one of the major triggers of upper gastrointestinal bleeding in children. Bleeding episodes have a remarkable effect on the quality of life of affected patients. Thus, appropriate diagnosis and treatment are needed in order to reduce morbidity and mortality.

  11. Splanchnic-aortic inflammatory axis in experimental portal hypertension

    Science.gov (United States)

    Aller, Maria-Angeles; de las Heras, Natalia; Nava, Maria-Paz; Regadera, Javier; Arias, Jaime; Lahera, Vicente

    2013-01-01

    Splanchnic and systemic low-grade inflammation has been proposed to be a consequence of long-term prehepatic portal hypertension. This experimental model causes minimal alternations in the liver, thus making a more selective study possible for the pathological changes characteristic of prehepatic portal hypertension. Low-grade splanchnic inflammation after long-term triple partial portal vein ligation could be associated with liver steatosis and portal hypertensive intestinal vasculopathy. In fact, we have previously shown that prehepatic portal hypertension in the rat induces liver steatosis and changes in lipid and carbohydrate metabolism similar to those produced in chronic inflammatory conditions described in metabolic syndrome in humans. Dysbiosis and bacterial translocation in this experimental model suggest the existence of a portal hypertensive intestinal microbiome implicated in both the splanchnic and systemic alterations related to prehepatic portal hypertension. Among the systemic impairments, aortopathy characterized by oxidative stress, increased levels of proinflammatory cytokines and profibrogenic mediators stand out. In this experimental model of long-term triple portal vein ligated-rats, the abdominal aortic proinflammatory response could be attributed to oxidative stress. Thus, the increased aortic reduced-nicotinamide-adenine dinucleotide phosphate [NAD(P)H] oxidase activity could be associated with reactive oxygen species production and promote aortic inflammation. Also, oxidative stress mediated by NAD(P)H oxidase has been associated with risk factors for inflammation and atherosclerosis. The splanchnic and systemic pathology that is produced in the long term after triple partial portal vein ligation in the rat reinforces the validity of this experimental model to study the chronic low-grade inflammatory response induced by prehepatic portal hypertension. PMID:24307792

  12. Ultrasonography for Noninvasive Assessment of Portal Hypertension.

    Science.gov (United States)

    Maruyama, Hitoshi; Yokosuka, Osamu

    2017-07-15

    Portal hypertension is a major pathophysiology in patients with cirrhosis. Portal pressure is the gold standard to evaluate the severity of portal hypertension, and radiological intervention is the only procedure for pressure measurement. Ultrasound (US) is a simple and noninvasive imaging modality available worldwide. B-mode imaging allows broad applications for patients to detect and characterize chronic liver diseases and focal hepatic lesions. The Doppler technique offers real-time observation of blood flow with qualitative and quantitative assessments, and the application of microbubble-based contrast agents has improved the detectability of peripheral blood flow. In addition, elastography for the liver and spleen covers a wider field beyond the original purpose of fibrosis assessment. These developments enhance the practical use of US in the evaluation of portal hemodynamic abnormalities. This article reviews the recent progress of US in the assessment of portal hypertension.

  13. Portal in the power sector - it is vision or reality?

    International Nuclear Information System (INIS)

    Hornak, L.

    2004-01-01

    The goal of the presentation is to introduce the portal solutions, to describe the types, characteristic features and abilities of the portal and to define required attributes of the portal in the power segment. The author will try to answer the questions whether such portal exists at the present time, what is needed in order to implement the portal and how to do the portal maintenance and management

  14. FDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT

    Directory of Open Access Journals (Sweden)

    Canh Nguyen

    2015-01-01

    Full Text Available Objective(s: In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT, complicating hepatocellular carcinoma (HCC in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT, which is a combination of dynamic liver CT scan, multiphase imaging, and whole-body PET scan. PET and CT DICOM images of patients were imported into the PET/CT imaging system for the re-analysis of contrast enhancement and FDG uptake in thrombus, the diameter of the involved portal vein, and characteristics of liver tumors and metastasis. Results: Two patients with previously untreated HCC and 7 cases with previously treated HCC had FDG-avid PVTT in contrast-enhanced FDG PET/CT scan. During the arterial phase of CT scan, portal vein thrombus showed contrast enhancement in 8 out of 9 patients (88.9%. PET scan showed an increased linear FDG uptake along the thrombosed portal vein in all patients. The mean greatest diameter of thrombosed portal veins was 1.8 ± 0.2 cm, which was significantly greater than that observed in normal portal veins (P<0.001. FDG uptake level in portal vein thrombus was significantly higher than that of blood pool in the reference normal portal vein (P=0.001. PVTT was caused by the direct extension of liver tumors. All patients had visible FDG-avid liver tumors in contrast-enhanced images. Five out of 9 patients (55.6% had no extrahepatic metastasis, 3 cases (33.3% had metastasis of regional lymph nodes, and 1 case (11.1% presented with distant metastasis. The median estimated survival time of patients was 5 months. Conclusion: The intraluminal filling defect consistent with thrombous within the portal vein, expansion of the involved portal vein, contrast enhancement, and linear increased FDG uptake of the thrombus extended from liver tumor are

  15. Neuropeptide Y restores non-receptor-mediated vasoconstrictive action in superior mesenteric arteries in portal hypertension.

    Science.gov (United States)

    Hartl, Johannes; Dietrich, Peter; Moleda, Lukas; Müller-Schilling, Martina; Wiest, Reiner

    2015-12-01

    Vascular hyporeactivity to vasoconstrictors contributes to splanchnic arterial vasodilatation and hemodynamic dysregulation in portal hypertension. Neuropeptide Y (NPY), a sympathetic cotransmitter, has been shown to improve adrenergic vascular contractility in portal hypertensive rats and markedly attenuate hyperdynamic circulation. To further characterize the NPY-effects in portal hypertension, we investigated its role for non-receptor-mediated vasoconstriction in the superior mesenteric artery (SMA) of portal vein ligated (PVL) and sham-operated rats. Ex vivo SMA perfusion of PVL and sham rats was used to analyse the effects of NPY on pressure response to non-receptor-mediated vasoconstriction. Dose-response curves to KCl (30-300 mM) were used to bypass G protein-coupled receptor mechanisms. Potential involvement of the cyclooxygenase-pathway was tested by non-selective cyclooxygenase-inhibition using indomethacin. KCl-induced vascular contractility but not vascular sensitivity was significantly attenuated in PVL rats as compared with sham rats. Administration of NPY resulted in an augmentation of KCl-evoked vascular sensitivity being not different between study groups. However, KCl-induced vascular contractility was markedly more enhanced in PVL rats, thus, vascular response was no more significantly different between PVL and sham rats after addition of NPY. Administration of indomethacin abolished the NPY-induced enhancement of vasoconstriction. Receptor-independent vascular contractility is impaired in mesenteric arteries in portal hypertension. NPY improves non-receptor mediated mesenteric vasoconstriction more effective in portal hypertension than in healthy conditions correcting splanchnic vascular hyporesponsiveness. This beneficial vasoactive action of NPY adds to its well known more pronounced effects on adrenergic vasoconstriction in portal hypertension making it a promising therapeutic agent in portal hypertension. © 2015 John Wiley & Sons A

  16. Wedge-shaped lesion in the liver seen on postoperative CT. Probable thromboembolic phenomenon in the portal venous system

    International Nuclear Information System (INIS)

    Yoshimitsu, K.; Charnsangavej, C.; Mi Park, J.; Ibukuro, K.

    1996-01-01

    Retrospective review of teaching files in our institution revealed 18 cases showing postoperative WSL in the liver. We also retrospectively reviewed CT images of the liver in 104 patients with a recent history of abdominopelvic surgery performed during a period of 12 months, as well as in 102 patients with no history of surgery during the same period to be used as control. Three additional patients with WSL were found in the postoperative group and none in the control group. Liver CT images from the 21 patients showing WSL, along with their clinical data and follow-up CT where available, were retrospectively analyzed. I.v. contrast-enhanced CT showed homogeneous higher attenuation of WSL than the surrounding liver in all cases; unenhanced CT showed low density in 5 patients, isodensity in 7 patients, and high density in 5 patients as compared with the surrounding liver. Density of unenhanced CT was significantly correlated with the presence or grade of fatty liver. In 5 cases CT demonstrated clots in the portal vein branch within the area of WSL and in 2 cases portal perfusion defects were observed on arterial portal CT, corresponding to the areas of WSL. Follow-up CT examinations were available on 15 patients: WSL became less prominent, or atrophic, or showed no change in 10, 2 and 3 patients respectively. Follow-up CT showed development of liver metastasis in only 3 cases. Only 2 of the 21 patients were clinically symptomatic; one had postoperative ileus and the other obstructive jaundice. Postoperative WSL may represent a thromboembolic phenomenon at the peripheral intrahepatic branch of the portal venous system during or after abdominopelvic surgery, resulting in a compensatory increase in the hepatic arterial flow that appears as wedge-shaped enhancement on CT. (orig./MG)

  17. Thrombosis of the portal vein in a miniature schnauzer.

    Science.gov (United States)

    Díaz Espiñeira, M M; Vink-Nooteboom, M; Van den Ingh, T S; Rothuizen, J

    1999-11-01

    A miniature schnauzer with a history of apathy, anorexia and jaundice was presented to the Utrecht University Clinic for Companion Animals. Abnormal laboratory findings included highly increased levels of total bile acids and alkaline phosphatase, and hyponatraemia. Abdominal ultrasonography revealed that the right side of the liver was enlarged and the left side was small, together with a thrombus in the portal vein. Biopsies from the right side of the liver demonstrated subacute to chronic active hepatitis, for which the dog was treated with prednisolone (1 mg/kg/day for four weeks). No improvement was observed and the owner requested euthanasia. At necropsy the left lobes of the liver were found to be small and firm, while the right lobes were large and soft. There were two thrombi in the portal vein. Microscopic examination revealed chronic active hepatitis and cirrhosis.

  18. Analysis of risk factors for rebleeding after splenectomy and pericardial devascularization in treatment of portal hypertension due to liver cirrhosis

    Directory of Open Access Journals (Sweden)

    ZHANG Lei

    2015-03-01

    Full Text Available ObjectiveTo investigate the possible risk factors for rebleeding after splenectomy and pericardial devascularization in the treatment of portal hypertension due to liver cirrhosis, and to provide a certain basis for reducing the incidence of digestive tract re-hemorrhage for these patients. MethodsA retrospective analysis was performed on 238 cirrhotic patients with portal hypertension who underwent splenectomy and pericardial devascularization in the First Hospital of Lanzhou University from December 2003 to December 2013. These patients were divided into postoperative rebleeding group (n=32 and non-bleeding group (n=206. Univariate analysis (t test or chi-square test and multivariate logistic regression analysis were performed to investigate the risk factors for rebleeding after splenectomy and pericardial devascularization. ResultsOf the 32 patients with postoperative rebleeding, 17 had esophagogastric variceal bleeding, 11 had bleeding due to portal hypertensive gastropathy, and 4 had stress ulcer bleeding. The univariate analysis showed that there were significant differences between the two groups in the following factors: Child-Pugh classification of liver function, degree of liver cirrhosis evaluated intraoperatively, pathological changes of the gastric mucosa, platelet count, prothrombin time (PT, activated partial thromboplastin time (APTT, and presence of diabetes (all P<0.05. The multivariate logistic regression analysis suggested that the significant independent influential factors for postoperative rebleeding were presence of diabetes, Child-Pugh classification of liver function, degree of liver cirrhosis evaluated intraoperatively, diffuse lesion of the gastric mucosa, PT, and APTT. ConclusionFor cirrhotic patients with portal hypertension, the appropriate methods for managing these risk factors are of great clinical significance for preventing rebleeding after splenectomy and pericardial devascularization.

  19. A two-dimensional matrix correction for off-axis portal dose prediction errors

    International Nuclear Information System (INIS)

    Bailey, Daniel W.; Kumaraswamy, Lalith; Bakhtiari, Mohammad; Podgorsak, Matthew B.

    2013-01-01

    Purpose: This study presents a follow-up to a modified calibration procedure for portal dosimetry published by Bailey et al. [“An effective correction algorithm for off-axis portal dosimetry errors,” Med. Phys. 36, 4089–4094 (2009)]. A commercial portal dose prediction system exhibits disagreement of up to 15% (calibrated units) between measured and predicted images as off-axis distance increases. The previous modified calibration procedure accounts for these off-axis effects in most regions of the detecting surface, but is limited by the simplistic assumption of radial symmetry. Methods: We find that a two-dimensional (2D) matrix correction, applied to each calibrated image, accounts for off-axis prediction errors in all regions of the detecting surface, including those still problematic after the radial correction is performed. The correction matrix is calculated by quantitative comparison of predicted and measured images that span the entire detecting surface. The correction matrix was verified for dose-linearity, and its effectiveness was verified on a number of test fields. The 2D correction was employed to retrospectively examine 22 off-axis, asymmetric electronic-compensation breast fields, five intensity-modulated brain fields (moderate-high modulation) manipulated for far off-axis delivery, and 29 intensity-modulated clinical fields of varying complexity in the central portion of the detecting surface. Results: Employing the matrix correction to the off-axis test fields and clinical fields, predicted vs measured portal dose agreement improves by up to 15%, producing up to 10% better agreement than the radial correction in some areas of the detecting surface. Gamma evaluation analyses (3 mm, 3% global, 10% dose threshold) of predicted vs measured portal dose images demonstrate pass rate improvement of up to 75% with the matrix correction, producing pass rates that are up to 30% higher than those resulting from the radial correction technique alone. As

  20. INVASIVE AND NON-INVASIVE TECHNIQUES FOR DETECTING PORTAL HYPERTENSION AND PREDICTING VARICEAL BLEEDING IN CIRRHOSIS: A REVIEW

    Science.gov (United States)

    Zardi, Enrico Maria; Di Matteo, Francesco Maria; Pacella, Claudio Maurizio; Sanyal, Arun J

    2016-01-01

    Portal hypertension is a severe syndrome that may derive from pre-sinusoidal, sinusoidal and post-sinusoidal causes. As a consequence, several complications (i.e., ascites, oesophageal varices) may develop. In sinusoidal portal hypertension, hepatic venous pressure gradient (HVPG) is a reliable method for defining the grade of portal pressure, establishing the effectiveness of the treatment and predicting the occurrence of complications; however, some questions exist regarding its ability to discriminate bleeding from nonbleeding varices in cirrhotic patients. Other imaging techniques (transient elastography, endoscopy, endosonography and duplex Doppler sonography) for assessing causes and complications of portal hypertensive syndrome are available and may be valuable for the management of these patients. In this review, we evaluate invasive and non-invasive techniques currently employed to obtain a clinical prediction of deadly complications, such as variceal bleeding in patients affected by sinusoidal portal hypertension, in order to create a diagnostic algorithm to manage them. Again, HVPG appears to be the reference standard to evaluate portal hypertension and monitor the response to treatment, but its ability to predict several complications and support management decisions might be further improved through the diagnostic combination with other imaging techniques. PMID:24328372

  1. Information Portal Costs and Benefits

    Directory of Open Access Journals (Sweden)

    Lorena BATAGAN

    2006-01-01

    Full Text Available All transformations of our society are the product of the large use of Information and Communications Technologies (ICT and Internet. ICT are technologies which facilitate communication, processing, and transmission of information by electronic means. It is very important to use the new technologies to the correct value because this determinate an increase of global benefits. Portal provides a consistent way to select, evaluate, prioritize and plan the right information. In research we point the important costs and benefits for an informational portal. The portal for local administrative determinate for citizens the access to information of interest and on the other hand make easier for employer to manage the documents.

  2. An empirical analysis of ontology reuse in BioPortal.

    Science.gov (United States)

    Ochs, Christopher; Perl, Yehoshua; Geller, James; Arabandi, Sivaram; Tudorache, Tania; Musen, Mark A

    2017-07-01

    Biomedical ontologies often reuse content (i.e., classes and properties) from other ontologies. Content reuse enables a consistent representation of a domain and reusing content can save an ontology author significant time and effort. Prior studies have investigated the existence of reused terms among the ontologies in the NCBO BioPortal, but as of yet there has not been a study investigating how the ontologies in BioPortal utilize reused content in the modeling of their own content. In this study we investigate how 355 ontologies hosted in the NCBO BioPortal reuse content from other ontologies for the purposes of creating new ontology content. We identified 197 ontologies that reuse content. Among these ontologies, 108 utilize reused classes in the modeling of their own classes and 116 utilize reused properties in class restrictions. Current utilization of reuse and quality issues related to reuse are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. The transjugular portosystemic stent shunt (TIPSS) as an intervention in clinical complication of portal hypertension; Der transjugulaere portosystemische Stentshunt (TIPSS) als Intervention bei klinischen Komplikationen der portalen Hypertonie

    Energy Technology Data Exchange (ETDEWEB)

    Thalhammer, A.; Jacobi, V.; Schwarz, W.; Balzer, J.; Abolmaali, N.; Vogl, T.J. [Frankfurt Univ. (Germany). Zentrum der Radiologie

    2001-10-01

    Most frequent complications in patients with liver cirrhosis are due to portal hypertension. Beside ascites circumvent vessles formate with vasodilatation. Due to counterregulation a secondary hyperaldosteronism develops with release of vasocontrictive agents. If conservative and endoscopic methods fail, indication for building a portosystemic shunt is given. The TIPSS procedure is less invasive than the surgical method of Warren-Shunt, so the radiological intervention has replaced surgery. Reducing the portal pressure by the shunt, the clinical complications change for the better. Still problems are defined as hepatic encephalopathy and right ventricular heart failure. Regular follow up investigations have to be performed to detect complications in the shunt. Using regular clinical and radiological check up TIPSS is of clinical benefit with good long term results. (orig.) [German] Die haeufigsten Komplikationen bei Patienten mit einer Leberzirrhose lassen sich auf das Vorliegen einer portalen Hypertension zurueckfuehren. Neben einer Aszitesbildung kommt es zur Vasodilatation mit Ausbildung portaler Umgehungskreislaeufe, gegenregulatorisch zu einem sekundaeren Hyperaldosteronismus und Ausschuettung vasokonstriktiver Substanzen. Sind mittels konservativer und endoskopischer Methoden die Komplikationen nicht mehr zu beherrschen, ist die Indikation zur Shuntanlage gegeben. Wegen der geringeren Invasivitaet einer TIPSS-Anlage gegenueber der operativen Methode eines Warren-Shunts hat sich die interventionell radiologische Methodik in den letzten Jahren immer mehr durchgesetzt. Durch den mittels Shuntanlage reduzierten Pfortaderdruck kommt es zu einer deutlichen klinischen Besserung der unterschiedlichen Komplikationen. Als klinisch problematische Symptome bei der Shuntanlage sind die hepatische Enzephalopathie und eine Zunahme der Rechtsherzbelastung zu werten. Um Komplikationen im Bereich des Shunts frueh zu erkennen, muss dieser engmaschig kontrolliert werden. Unter

  4. Portal Hypertension Over the Last 25 Years: Where Did It Go?

    Science.gov (United States)

    Rosemurgy, Alexander; Raitano, Olivia; Srikumar, Thejal; Sawangkum, Peeraya; Luberice, Kenneth; Ryan, Carrie; Ross, Sharona

    2016-06-01

    Portal hypertension has seemingly vanished from surgery; this study was undertaken to determine where it has gone. Data from the Agency for Health Care Administration for 33,166,201 hospital inpatients in Florida for the periods 1988 to 1992, 1998 to 2002, and 2008 to 2012 were analyzed. Admissions with a diagnosis of portal hypertension dramatically increased: 5,473 patients from 1988 to 1992, 7,366 patients from 1998 to 2002, and 36,554 patients from 2008 to 2012. Endoscopic treatment of esophageal varices also dramatically increased. The number of decompressive shunts placed nominally increased, but application of endoscopic therapy increased significantly faster than the application of decompressive shunts (p portal hypertension, in-hospital mortality progressively decreased, from 9% in 1988 to 1992 to 3% in 2008 to 2012 (p portal hypertension, with a 65% reduction of in-hospital mortality. Application of endoscopic treatment of varices has increased dramatically. Decompressive shunts are applied to an ever-decreasing percentage of patients, and when applied, are now routinely undertaken by nonsurgeons. Therefore, portal hypertension has disappeared from the purview of surgery and has migrated toward the world of medical and endoscopic therapy, probably never to return. Copyright © 2016. Published by Elsevier Inc.

  5. Metabolic effects of portal vein sensing.

    Science.gov (United States)

    Mithieux, G

    2014-09-01

    The extrinsic gastrointestinal nerves are crucial in the sensing of nutrients and hormones and its translation in terms of control of food intake. Major macronutrients like glucose and protein are sensed by the extrinsic nerves located in the portal vein walls, which signal to the brain and account for the satiety phenomenon they promote. Glucose is sensed in the portal vein by neurons expressing the glucose receptor SGLT3, which activate the main regions of the brain involved in the control of food intake. Proteins indirectly act on food intake by inducing intestinal gluconeogenesis and its sensing by the portal glucose sensor. The mechanism involves a prior antagonism by peptides of the μ-opioid receptors present in the portal vein nervous system and a reflex arc with the brain inducing intestinal gluconeogenesis. In a comparable manner, short-chain fatty acids produced from soluble fibre act via intestinal gluconeogenesis to exert anti-obesity and anti-diabetic effects. In the case of propionate, the mechanism involves a prior activation of the free fatty acid receptor FFAR3 present in the portal nerves and a reflex arc initiating intestinal gluconeogenesis. © 2014 John Wiley & Sons Ltd.

  6. Arachidonic acid metabolites and endothelial dysfunction of portal hypertension.

    Science.gov (United States)

    Sacerdoti, David; Pesce, Paola; Di Pascoli, Marco; Brocco, Silvia; Cecchetto, Lara; Bolognesi, Massimo

    2015-07-01

    Increased resistance to portal flow and increased portal inflow due to mesenteric vasodilatation represent the main factors causing portal hypertension in cirrhosis. Endothelial cell dysfunction, defined as an imbalance between the synthesis, release, and effect of endothelial mediators of vascular tone, inflammation, thrombosis, and angiogenesis, plays a major role in the increase of resistance in portal circulation, in the decrease in the mesenteric one, in the development of collateral circulation. Reduced response to vasodilators in liver sinusoids and increased response in the mesenteric arterioles, and, viceversa, increased response to vasoconstrictors in the portal-sinusoidal circulation and decreased response in the mesenteric arterioles are also relevant to the pathophysiology of portal hypertension. Arachidonic acid (AA) metabolites through the three pathways, cyclooxygenase (COX), lipoxygenase, and cytochrome P450 monooxygenase and epoxygenase, are involved in endothelial dysfunction of portal hypertension. Increased thromboxane-A2 production by liver sinusoidal endothelial cells (LSECs) via increased COX-1 activity/expression, increased leukotriens, increased epoxyeicosatrienoic acids (EETs) (dilators of the peripheral arterial circulation, but vasoconstrictors of the portal-sinusoidal circulation), represent a major component in the increased portal resistance, in the decreased portal response to vasodilators and in the hyper-response to vasoconstrictors. Increased prostacyclin (PGI2) via COX-1 and COX-2 overexpression, and increased EETs/heme-oxygenase-1/K channels/gap junctions (endothelial derived hyperpolarizing factor system) play a major role in mesenteric vasodilatation, hyporeactivity to vasoconstrictors, and hyper-response to vasodilators. EETs, mediators of liver regeneration after hepatectomy and of angiogenesis, may play a role in the development of regenerative nodules and collateral circulation, through stimulation of vascular endothelial

  7. Kupffer cells are activated in cirrhotic portal hypertension and not normalised by TIPS.

    Science.gov (United States)

    Holland-Fischer, Peter; Grønbæk, Henning; Sandahl, Thomas Damgaard; Moestrup, Søren K; Riggio, Oliviero; Ridola, Lorenzo; Aagaard, Niels Kristian; Møller, Holger Jon; Vilstrup, Hendrik

    2011-10-01

    Hepatic macrophages (Kupffer cells) undergo inflammatory activation during the development of portal hypertension in experimental cirrhosis; this activation may play a pathogenic role or be an epiphenomenon. Our objective was to study serum soluble CD163 (sCD163), a sensitive marker of macrophage activation, before and after reduction of portal venous pressure gradient by insertion of a transjugular intrahepatic portosystemic shunt (TIPS) in patients with cirrhosis. sCD163 was measured in 11 controls and 36 patients before and 1, 4 and 26 weeks after TIPS. We used lipopolysaccharide binding protein (LBP) levels as a marker of endotoxinaemia. Liver function and clinical status of the patients were assessed by galactose elimination capacity and Model for End Stage Liver Disease score. The sCD163 concentration was more than threefold higher in the patients than in the controls (median 5.22 mg/l vs 1.45 mg/l, pportal venous pressure gradient (r(2)=0.24, pportal vein (pportal hypertension. The activation was not alleviated by the mechanical reduction of portal hypertension and the decreasing signs of endotoxinaemia. The findings suggest that Kupffer cell activation is a constitutive event that may play a pathogenic role for portal hypertension.

  8. Disastrous Portal Vein Embolization Turned into a Successful Intervention

    Energy Technology Data Exchange (ETDEWEB)

    Dobrocky, Tomas, E-mail: tomas.dobrocky@insel.ch [University of Bern, Department of Interventional, Pediatric and Diagnostic Radiology, Inselspital, University Hospital (Switzerland); Kettenbach, Joachim, E-mail: joachim.kettenbach@stpoelten.lknoe.at [Universitätsklinikum St. Pölten-Lilienfeld, Institute of Medical Radiology, Diagnostic, Intervention (Austria); Lopez-Benitez, Ruben, E-mail: Ruben.lopez@insel.ch; Kara, Levent, E-mail: levent.kara@insel.ch [University of Bern, Department of Interventional, Pediatric and Diagnostic Radiology, Inselspital, University Hospital (Switzerland)

    2015-10-15

    Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloon catheter, inflating the balloon, and pulling the plug into the main right portal vein.

  9. Portal monitor incorporating smart probes

    International Nuclear Information System (INIS)

    Bartos, D.; Constantin, F.; Guta, T.

    2003-01-01

    Portal monitors are intended for detection of radioactive and special nuclear materials in vehicles, pedestrians, luggage, as well as for prevention of illegal traffic of radioactive sources. Monitors provide audio and visual alarms when radioactive and/or special nuclear materials are detected. They can be recommended to officers of customs, border guard and emergency services, civil defense, fire brigades, police and military departments or nuclear research or energetic facilities. The portal monitor developed by us consists in a portal frame, which sustains five intelligent probes having long plastic scintillator (0.5 liters each). The probes communicate, by serial transmission, with a Central Unit constructed on the basis of the 80552 microcontroller. This one manages the handshake, calculates the background, establishes the measuring time, starts and stops each measurement and makes all the other decisions. Sound signals and an infrared sensor monitor the passing through the portal and the measuring procedure. For each measurement the result is displayed on a LCD device contaminated/uncontaminated; for the contaminated case a loud and long sound signal is also issued. An RS 232 serial interface is provided in order to further developments or custom made devices. As a result, the portal monitor detects 1 μ Ci 137 Cs, spread all over a human body, in a 20 μR/h gamma background for a measuring time of 1.5 or 10 seconds giving a 99% confidence factor. (authors)

  10. High signal intensity lesion in basal ganglia on MR imaging: correlation with portal-systemic encephalopathy in liver cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yun Ju; Choi, Sun Jeong; Kim, Chang Soo; Kim, Sun Hee; Chung, Chun Phil; Kim, Yang Sook [Maryknoll Hospital, Pusan (Korea, Republic of)

    1993-01-15

    To evaluate of the relationship between basal ganglia lesion and portal-systemic encephalopathy, eleven patients who had clinically proved liver cirrhosis with superior mesenteric vein larger than 10mm in diameter on ultrasonogram underwent brain MR imaging. No evidence of clinical or neuropsychiatric disturbance was observed in any patient at the time of the MR examination. Brain MR imaging revealed basal ganglia lesion characterized by bilateral, symmetric, high signal intensity without edema or mass effect on spin echo T1-weighted images in nine patients which included three patients with the past history of portal-systemic encephalopathy. It was concluded that excepted in the circumstances of other causes of the high signal intensity in basal ganglia on T1-weighted images such as fat, methemoglobin, melanin, neurofibromatosis, dense calcification, and parenteral nutrition, bilateral and symmetric high signal intensity lesion in basal ganglia would be a useful MR finding of subclinical portal-systemic encephalopathy in liver cirrhosis patients with no clinical or neuropsychiatric symptoms and larger than 10mm in diameter of superior mesenteric vein in ultrasonography.

  11. High signal intensity lesion in basal ganglia on MR imaging: correlation with portal-systemic encephalopathy in liver cirrhosis

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Choi, Sun Jeong; Kim, Chang Soo; Kim, Sun Hee; Chung, Chun Phil; Kim, Yang Sook

    1993-01-01

    To evaluate of the relationship between basal ganglia lesion and portal-systemic encephalopathy, eleven patients who had clinically proved liver cirrhosis with superior mesenteric vein larger than 10mm in diameter on ultrasonogram underwent brain MR imaging. No evidence of clinical or neuropsychiatric disturbance was observed in any patient at the time of the MR examination. Brain MR imaging revealed basal ganglia lesion characterized by bilateral, symmetric, high signal intensity without edema or mass effect on spin echo T1-weighted images in nine patients which included three patients with the past history of portal-systemic encephalopathy. It was concluded that excepted in the circumstances of other causes of the high signal intensity in basal ganglia on T1-weighted images such as fat, methemoglobin, melanin, neurofibromatosis, dense calcification, and parenteral nutrition, bilateral and symmetric high signal intensity lesion in basal ganglia would be a useful MR finding of subclinical portal-systemic encephalopathy in liver cirrhosis patients with no clinical or neuropsychiatric symptoms and larger than 10mm in diameter of superior mesenteric vein in ultrasonography

  12. Studi Respon Seismik Penggunaan Steel Slit Damper (SSD pada Portal Baja

    Directory of Open Access Journals (Sweden)

    Lisa Ika Arumsari

    2012-09-01

    Full Text Available Salah satu metode yang dapat digunakan untuk mengurangi dampak dari beban gempa terhadap portal baja adalah menggunakan peredam. Steel Slit Damper (SSD adalah salah satu jenis peredam yang dibuat dari sejumlah pelat baja lunak berbentuk segi-4 yang dimodelkan sebagai pegas-pegas yang disusun secara seri. Energi akibat gempa disalurkan melalui strip-strip damper yang mudah meleleh ketika perangkat mengalami deformasi inelastis siklik. SSD mendisipasi energi melalui pembentukan sendi plastis atau pelelehan pelat damper. Pada penelitian ini dilakukan analisa respon seismik Steel Slit Damper (SSD pada portal baja 1 lantai yang menerima beban lateral berupa beban gempa, dengan membandingkan portal baja konvensional, portal baja inverted-v, dan portal baja dengan SSD. Hasil analisa menunjukkan bahwa gaya geser, gaya normal, dan momen yang dihasikan portal dengan SSD lebih kecil hingga 80,49% dari gaya-gaya yang dihasilkan portal konvensional, tetapi gaya-gaya tersebut masih lebih besar daripada yang dihasilkan portal inverted-V. Portal dengan SSD dapat memperkecil simpangan sebesar 94,12% pada portal konvensional dan sebesar 33,33% pada portal bracing inverted-v. Hasil penelitian juga menunjukkan bahwa portal SSD memiliki daktilitas 105,85% lebih tinggi dari portal konvensional dan 298,67% lebih tinggi dari portal bracing inverted-v

  13. Endothelial dysfunction in the regulation of portal hypertension

    Science.gov (United States)

    Iwakiri, Yasuko

    2013-01-01

    Portal hypertension is caused by an increased intrahepatic resistance, a major consequence of cirrhosis. Endothelial dysfunction in liver sinusoidal endothelial cells (LSECs) decreases the production of vasodilators, such as nitric oxide (NO) and favors vasoconstriction. This contributes to an increased vascular resistance in the intrahepatic/sinusoidal microcirculation. Portal hypertension, once developed, causes endothelial cell (EC) dysfunction in the extrahepatic, i.e. splanchnic and systemic, circulation. Unlike LSEC dysfunction, EC dysfunction in the splanchnic and systemic circulation overproduces vasodilator molecules, leading to arterial vasodilatation. In addition, portal hypertension leads to the formation of portosystemic collateral vessels. Both arterial vasodilatation and portosystemic collateral vessel formation exacerbate portal hypertension by increasing the blood flow through the portal vein. Pathologic consequences, such as esophageal varices and ascites, result. While the sequence of pathological vascular events in cirrhosis and portal hypertension have been elucidated, the underlying cellular and molecular mechanisms causing EC dysfunctions are not yet fully understood. This review article summarizes the current cellular and molecular studies on EC dysfunctions found during the development of cirrhosis and portal hypertension with a focus on intra- and extrahepatic circulation. The article ends by discussing future directions of study for EC dysfunctions. PMID:21745318

  14. Randomised clinical study: the effects of oral taurine 6g/day vs placebo on portal hypertension.

    Science.gov (United States)

    Schwarzer, R; Kivaranovic, D; Mandorfer, M; Paternostro, R; Wolrab, D; Heinisch, B; Reiberger, T; Ferlitsch, M; Gerner, C; Trauner, M; Peck-Radosavljevic, M; Ferlitsch, A

    2018-01-01

    The amino sulphonic acid taurine reduces oxidative endoplasmatic reticulum stress and inhibits hepatic stellate cell activation, which might lead to reduction of portal pressure in cirrhosis. To assess the haemodynamic effects of taurine supplementation in patients with cirrhosis and varices. Patients with hepatic venous pressure gradient (HVPG) ≥12 mm Hg were included in this prospective proof of concept study. Concomitant nonselective beta-blockers therapy was not allowed. Patients received either 4 weeks of oral taurine (6 g/day), or placebo, prior to evaluation of HVPG response. Thirty patients were screened and 22 included in the efficacy analysis (12 taurine/10 placebo; 64% male, mean age: 52 ± 11 years, Child A: 9%, B:64%, C:27%, ascites:68%). In the taurine group, mean HVPG dropped from 20 mm Hg (±4) at baseline to 18 mm Hg (±4) on day 28 (mean relative change: -12%, P = .0093). In the placebo group, mean HVPG increased from 20 mm Hg (±5) at baseline to 21 mm Hg (±5) on day 28 (mean relative change:+2%, P = .4945). Taurine had no significant effects on systemic haemodynamics. Seven of 12 patients (58%) on taurine achieved a HVPG response >10%, compared to none in the placebo group (P = .0053). In a multivariate linear model, HVPG reduction was significantly larger in the taurine group compared to placebo group (P = .0091 and P = .0109 for absolute and relative change respectively). Treatment-related adverse events included gastrointestinal discomfort and fatigue, and were usually mild and comparable between treatment groups. Taurine is safe and may reduce portal pressure in cirrhotic patients. More studies on the underlying mechanisms of action and long-term effects of taurine supplementation are warranted. © 2017 John Wiley & Sons Ltd.

  15. Study in rabbits of portal circulation by a radioisotopic method

    International Nuclear Information System (INIS)

    Maliska, C.

    1980-01-01

    The development of a precocius - and noninvasive method for the detection of portal circulation alterations by means of time interval measurements between the rectal administration of radiotracers and their detection in liver and head is aimed at. The pertecnetate ( 99 sup(m)Tc)- and iodate ( 131 I) absorption by the terminal large intestine was tested in 22 rabbits. The time iinterval between rectal administration of the radiotracer and its appearance in liver and head was determined in 12 rabbits, by external detection with a scintillation camera. The same parameters were studied in 9 animals submitted to the ligature of the portal vein. Iodate and pertecnetate are absorbed by the terminal large intestine, the pertecnetate absorption being significantly smaller than that of iodate. The pertecnetate distribution volume is smaller than that of iodate; the rectum - liver - and rectum - head time intervals is increased in animals with the ligature of portal vein. Application of the method to larger animals will permit the necessary improvements for its utilization as a precocius - noninvasive - and inocuous test in the evaluation of alteration of the human portal circulation. (Author) [pt

  16. Duplication of the Portal Vein: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Won; Shin, Hyeong Cheol; Jou, Sung Shick; Han, Jong Kyu; Kim, Il Young [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of)

    2009-12-15

    The duplication of the portal vein is an uncommon congenital anomaly. To date, only four cases have been reported in the medical literature. This anomaly can cause portal hypertension in pediatric patients. In addition, duplication of the portal vein has various patterns of connection with a splenic vein or mesenteric veins, and it can lie anterior or posterior to the duodenum. We report the MDCT findings of an adult patient with duplication of the portal vein that was found incidentally

  17. Retrospective Study to Compare Selective Decongestive Devascularization and Gastrosplenic Shunt versus Splenectomy with Pericardial Devascularization for the Treatment of Patients with Esophagogastric Varices Due to Cirrhotic Portal Hypertension.

    Science.gov (United States)

    Bao, Haili; He, Qikuan; Dai, Ninggao; Ye, Ruifan; Zhang, Qiyu

    2017-06-08

    BACKGROUND For patients with esophagogastric varices secondary to portal hypertension due to liver cirrhosis, portosystemic shunts and devascularization have become the most commonly used treatment methods. We have developed a novel surgical approach for the treatment of patients with cirrhotic portal hypertension, selective decongestive devascularization, and shunt of the gastrosplenic region (SDDS-GSR). This aim of this study was to compare the efficacy and safety of SDDS-GSR with splenectomy with pericardial devascularization (SPD). MATERIAL AND METHODS A retrospective study was undertaken between 2006 and 2013 and included 110 patients with cirrhotic portal hypertension, 34 of whom underwent SDDS-GSR; 76 patients underwent SPD. Kaplan-Meier analysis was used to evaluate clinical outcomes, mortality, the incidence of re-bleeding, encephalopathy, and portal venous system thrombosis (PVST). RESULTS Postoperatively portal venous pressure decreased by 20% in both groups. The long-term incidence of re-bleeding and PVST was significantly lower in the SDDS-GSR group compared with the SPD group (P=0.018 and P=0.039, respectively). CONCLUSIONS This preliminary retrospective study has shown that SDDS-GSR was an effective treatment for patients with esophagogastric varices secondary to portal hypertension that may be used as a first-line treatment to prevent variceal bleeding and lower the incidence of PVST.

  18. MR and angiography: Evaluation of the hemodynamics of portal hypertension

    International Nuclear Information System (INIS)

    Torres, W.E.; Gaylord, G.M.; Whitmire, L.; Chuang, V.P.; Bernardino, M.E.

    1986-01-01

    Forty-two MR imaging examinations and angiographic procedures in 38 patients with portal hypertension were compared for how well the images depicted portal perfusion and direction of flow, portal vein thrombosis, and the presence and type of shunt. Thirty-three MR imaging studies indicated grade I or II portal flow. In 29 cases portal flow was grade I or II by angiography; in the remaining cases the flow was grade IV. In a total of eight cases portal flow was grade IV by angiography, but none appeared to be grade IV on MR imaging. Both MR imaging and angiography detected portal vein thrombosis (41 of 42 cases). MR imaging and angiography agreed as to whether a shunt was present or absent, and patent or occluded (41 of 42 cases). Currently, MR imaging is an unsatisfactory modality by which to grade portal flow. MR imaging does depict portal vein thrombosis well, and can be used to determine patency of surgical shunts

  19. The expression of PEDF and VEGF in the gastric wall of prehepatic portal hypertensive rats.

    Science.gov (United States)

    Pan, Wei-Dong; Liu, Yanzhang; Lin, Nan; Xu, Ruiyun

    2011-01-01

    Upper gastrointestinal bleeding of portal hypertension cases may result from gastric mucosal lesions due to portal hypertensive gastropathy. The pathological changes in the vessels of the gastric wall are very important in the pathogenesis of portal hypertensive gastropathy. However, the mechanisms of these pathological changes are not completely understood. In this study, we examined the expression levels of PEDF and VEGF in the gastric wall in rats with prehepatic portal hypertension. Eighteen healthy Wistar rats were randomly divided into groups A and B. Group A was used to establish the prehepatic portal hypertensive model and group B to evaluate a sham surgery. The VEGF and PEDF expression in the rat gastric wall were detected by immunohistochemical staining and western blotting. VEGF and PEDF were mainly expressed in the basal layer of the mucosal glands. The expression levels of VEGF and PEDF in group A were higher than that in group B at 7, 10 and 14 days after surgery. The expression levels of VEFG and PEDF in group B did not show significant changes. The results from the present study showed a significantly elevated expression of both VEGF and PEDF in the gastric walls during the development of portal hypertension. The expression of these proteins was mainly located in the basal layer of the gastric mucosa.

  20. Study of radiation portal monitor and its application to metal recycling industry

    International Nuclear Information System (INIS)

    Pujol, L.; Lara-Calleja, S.; Suarez-Navarro, M. J.; Gonzalez-Gonzalez, J. A.

    2009-01-01

    The industry of the iron and the steel in one of the most important sectors in Spain for its economic development. the recycling of metallic materials as well as the import of metallic scrap is very significant. Several reports on accidental dispersion or smelting of radioactive sources in metal recycling industries confirm the possibility that radioactive material might be mixed with scrap. In consequence, this type of accident shows the necessity of a rigorous and specific radiation control of the sector. The control of these materials with radioactive content can be carried out with radiation portal monitors installed at the entrance of these industries. The detection of radioactive materials presents special features as the continuous background acquisition or the minimisation of the relatively large number of innocent/nuisance detections. In the present work, we study a radiation portal monitor, the FHT-1388-T Thermo-Eberline. This is one of the usual radiation portal systems installed at the entrance of the metal recycling industry. Se study the characteristics and parameters of this portal monitor to optimise its use. furthermore, we propose some rapid tests for radiation portal systems in metal recycling industry. (Author) 16 refs

  1. Idiopathic portal hypertension regarding thiopurine treatment in patients with inflammatory bowel disease.

    Science.gov (United States)

    Suárez Ferrer, Cristina; Llop Herrera, Elba; Calvo Moya, Marta; Vera Mendoza, María Isabel; González Partida, Irene; González Lama, Yago; Matallana Royo, Virginia; Calleja Panero, José Luis; Abreu García, Luis

    2016-02-01

    The possibility of developing idiopathic portal hypertension has been described with thiopurine treatment despite compromises the prognosis of these patients, the fact its true prevalence is unknown. A cross-sectional study was conducted in a cohort of inflammatory bowel disease (IBD) patients followed at our unit, to determine the prevalence of diagnosis of idiopathic portal hypertension (IPH) and its relationship with thiopurine treatment. At the time of the analysis, 927/1,419 patients were under treatment with thiopurine drugs (65%). A total of 4 patients with IBD type Crohn's disease with idiopathic portal hypertension probably related to the thiopurine treatment were identified (incidence of 4.3 cases per 1,000). Seventy-five percent of patients started with signs or symptoms of portal hypertension. Only one patient was asymptomatic but the diagnosis of IPH because of isolated thrombocytopenia is suspected. However, note that all patients had thrombocytopenia previously. Abdominal ultrasound with fibroscan, hepatic vein catheterization and liver biopsy were performed on all of them as part of the etiology of portal hypertension. In the abdominal ultrasound, indirect portal hypertension data were observed in all patients (as splenomegaly) cirrhosis was also ruled out. The fibroscan data showed significant liver fibrosis (F2-F3). Idiopathic portal hypertension following thiopurine treatment in IBD patients is a rare occurrence, but it must be borne in mind in the differential diagnosis for early diagnosis, especially in patients undergoing thiopurine treatment over a long period. The presence of thrombocytopenia is often the only predictor of its development in the preclinical stage.

  2. The questions of working out radiology patterns of portal hypertension

    International Nuclear Information System (INIS)

    Vyikman, Ya.E.

    2008-01-01

    A foundation for radiological patterns of each type of portal hypertension (PH) at various stages of its development. Portal blood pressure, diameter of splenic and portal veins, volume blood flow velocity in the portal and splenic veins, incidence of hypersplenism, enlargement of the caudate lobe of the liver and gallbladder fossa are the most informative in differentiation of various forms of portal hypertension

  3. Calcification in the portal venous system demonstrated by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hadar, H; Sommer, R

    1983-08-01

    The CT appearance of calcification in the portal venous system in a patient with chronic alcoholic cirrhosis is presented. Reported cases of radiologically detectable calcification in the portal system are rare, and most of them have been associated with longstanding portal hypertension. We presume that with CT this diagnosis will be made more frequently. In the presence of calcification in the portal venous system, portal vein thrombosis is highly probable. This information is of obvious importance to the surgeon contemplating a portal decompressive shunt procedure.

  4. Splenomegaly, hyperkinetic splenic flow and portal hypertension in colitis

    International Nuclear Information System (INIS)

    Friman, L.

    1980-01-01

    Four patients with a long history of colitis, splenomegaly, hypersplenism and portal hypertension were examined with angiography, both with contrast medium and isotopes, liver-spleen scintigraphy and recording of portal pressure. At angiography hyperkinetic splenic and portal blood flow was demonstrated. The increased flow causes increased portal pressure, which probably gives rise to changes in the liver often considered as slight cirrhosis at microscopy. The scintigraphic findings differed from Laennec cirrhosis. The liver uptake was homogeneous and no activity in the skeleton was recorded. Splenectomy cures both the hypersplenism and portal hypertension. (Auth.)

  5. Portal hypertension as portrayed by marked hepatosplenomegaly: case report

    International Nuclear Information System (INIS)

    Greene, R.A.

    1987-01-01

    The liver is vulnerable to as host of disease processes, including portal hypertension. This is a severe hepatic condition in which the liver is subject to numerous imbalances: increased hepatic blood flow, increased portal vein pressure due to extrahepatic portal vein obstruction, and/or increases in hepatic blood flow resistance. Although many diseases states may be responsible for the development of portal hypertension, it is most commonly associated with moderately severe or advanced cirrhosis. Advanced, untreated portal hypertension may cause additional complications such as hepatosplenomegaly, gastrointestinal bleeding, and ascites

  6. Splenomegaly, hyperkinetic splenic flow and portal hypertension in colitis

    Energy Technology Data Exchange (ETDEWEB)

    Friman, L [Serafimerlasarettet, Stockholm (Sweden)

    1980-01-01

    Four patients with a long history of colitis, splenomegaly, hypersplenism and portal hypertension were examined with angiography, both with contrast medium and isotopes, liver-spleen scintigraphy and recording of portal pressure. At angiography hyperkinetic splenic and portal blood flow was demonstrated. The increased flow causes increased portal pressure, which probably gives rise to changes in the liver often considered as slight cirrhosis at microscopy. The scintigraphic findings differed from Laennec cirrhosis. The liver uptake was homogeneous and no activity in the skeleton was recorded. Splenectomy cures both the hypersplenism and portal hypertension.

  7. Attractive Interactions between Heteroallenes and the Cucurbituril Portal.

    Science.gov (United States)

    Reany, Ofer; Li, Amanda; Yefet, Maayan; Gilson, Michael K; Keinan, Ehud

    2017-06-21

    In this paper, we report on the noteworthy attractive interaction between organic azides and the portal carbonyls of cucurbiturils. Five homologous bis-α,ω-azidoethylammonium alkanes were prepared, where the number of methylene groups between the ammonium groups ranges from 4 to 8. Their interactions with cucurbit[6]uril were studied by NMR spectroscopy, IR spectroscopy, X-ray crystallography, and computational methods. Remarkably, while the distance between the portal plane and most atoms at the guest end groups increases progressively with the molecular size, the β-nitrogen atoms maintain a constant distance from the portal plane in all homologues, pointing at a strong attractive interaction between the azide group and the portal. Both crystallography and NMR support a specific electrostatic interaction between the carbonyl and the azide β-nitrogen, which stabilizes the canonical resonance form with positive charge on the β-nitrogen and negative charge on the γ-nitrogen. Quantum computational analyses strongly support electrostatics, in the form of orthogonal dipole-dipole interaction, as the main driver for this attraction. The alternative mechanism of n → π* orbital delocalization does not seem to play a significant role in this interaction. The computational studies also indicate that the interaction is not limited to azides, but generalizes to other isoelectronic heteroallene functions, such as isocyanate and isothiocyanate. This essentially unexploited attractive interaction could be more broadly utilized as a tool not only in relation to cucurbituril chemistry, but also for the design of novel supramolecular architectures.

  8. Tumor and liver drug uptake following hepatic artery and portal vein infusion

    International Nuclear Information System (INIS)

    Sigurdson, E.R.; Ridge, J.A.; Kemeny, N.; Daly, J.M.

    1987-01-01

    Anatomic dye injection studies of the blood supply of colorectal hepatic metastases suggest that tumors are supplied predominantly by the hepatic artery. Using 13 N amino acids with dynamic gamma camera imaging in patients with colorectal hepatic metastases, it has been shown that hepatic artery infusion results in a significantly greater nutrient delivery to tumor compared with portal vein infusion. However, direct measurements of drug levels in tumor following hepatic artery and portal vein infusion in humans have not previously been reported. Patients with metastatic colorectal cancer confined to the liver received fluorodeoxyuridine (FUdR) through the hepatic artery or through the portal vein. All patients had previously failed systemic chemotherapy. Five patients with hepatic artery catheters were matched (by age, serum lactic dehydrogenase levels, percent hepatic replacement, and tumor size) with five patients with portal vein catheters. At operation, 3 H-FUdR (1 microCi/kg) and /sup 99m/Tc-macroaggregated albumin (MAA) (6 mCi) were injected into the hepatic artery or portal vein. Liver and tumor biopsies were obtained two and five minutes later. 3 H and /sup 99m/Tc were measured per gram tissue by scintillation and gamma counting. The mean liver levels following hepatic artery infusion (23.9 +/- 11.4 nmol/g) and portal vein infusion (18.4 +/- 14.5 nmol/g) did not differ. However, the mean tumor FUdR level following hepatic artery infusion was 12.4 +/- 12.2 nmol/g, compared with a mean tumor FUdR level following portal vein infusion of 0.8 +/- 0.7 nmol/g (P less than .01). This low level of tumor drug uptake after portal vein infusion of FUdR predicts minimal tumor response to treatment via this route. Thus, regional chemotherapy for established colorectal hepatic metastases should be administered through the hepatic artery

  9. NASA Sea Level Change Portal - It not just another portal site

    Science.gov (United States)

    Huang, T.; Quach, N.; Abercrombie, S. P.; Boening, C.; Brennan, H. P.; Gill, K. M.; Greguska, F. R., III; Jackson, R.; Larour, E. Y.; Shaftel, H.; Tenenbaum, L. F.; Zlotnicki, V.; Moore, B.; Moore, J.; Boeck, A.

    2017-12-01

    The NASA Sea Level Change Portal (https://sealevel.nasa.gov) is designed as a "one-stop" source for current sea level change information, including interactive tools for accessing and viewing regional data, a virtual dashboard of sea level indicators, and ongoing updates through a suite of editorial products that include content articles, graphics, videos, and animations. With increasing global temperatures warming the ocean and melting ice sheets and glaciers, there is an immediate need both for accelerating sea level change research and for making this research accessible to scientists in disparate discipline, to the general public, to policy makers and business. The immersive and innovative NASA portal debuted at the 2015 AGU attracts thousands of daily visitors and over 30K followers on Facebook®. Behind its intuitive interface is an extensible architecture that integrates site contents, data for various sources, visualization, horizontal-scale geospatial data analytic technology (called NEXUS), and an interactive 3D simulation platform (called the Virtual Earth System Laboratory). We will present an overview of our NASA portal and some of our architectural decisions along with discussion on our open-source, cloud-based data analytic technology that enables on-the-fly analysis of heterogeneous data.

  10. Porto-systemic collaterals in cirrhosis of the liver. Selective percutaneous transhepatic catheterization of the portal venous system in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Hoevels, J; Lunderquist, A; Tylen, U; Simert, G [Lund Univ. (Sweden)

    1979-01-01

    In 93 patients with cirrhosis of the liver and portal venous hypertension the main tributaries of the portal vein were examined by percutaneous transhepatic catheterization. The appearance and degree of porto-systemic collaterals were analysed. Esophageal varices were demonstrated in 82 patients. No correlation was found between the portal venous pressure and the extent of porto-systemic communications.

  11. Portal vein branching order helps in the recognition of anomalous right-sided round ligament: common features and variations in portal vein anatomy.

    Science.gov (United States)

    Yamashita, Rikiya; Yamaoka, Toshihide; Nishitai, Ryuta; Isoda, Hiroyoshi; Taura, Kojiro; Arizono, Shigeki; Furuta, Akihiro; Ohno, Tsuyoshi; Ono, Ayako; Togashi, Kaori

    2017-07-01

    This study aimed to evaluate the common features and variations of portal vein anatomy in right-sided round ligament (RSRL), which can help propose a method to detect and diagnose this anomaly. In this retrospective study of 14 patients with RSRL, the branching order of the portal tree was analyzed, with special focus on the relationship between the dorsal branch of the right anterior segmental portal vein (P A-D ) and the lateral segmental portal vein (P LL ), to determine the common features. The configuration of the portal vein from the main portal trunk to the right umbilical portion (RUP), the inclination of the RUP, and the number and thickness of the ramifications branching from the right anterior segmental portal vein (P A ) were evaluated for variations. In all subjects, the diverging point of the P A-D was constantly distal to that of the P LL . The portal vein configuration was I- and Z-shaped in nine and five subjects, respectively. The RUP was tilted to the right in all subjects. In Z-shaped subjects, the portal trunk between the branching point of the right posterior segmental portal vein and that of the P LL was tilted to the left in one subject and was almost parallel to the vertical plane in four subjects. Multiple ramifications were radially distributed from the P A in eight subjects, whereas one predominant P A-D branched from the P A in six subjects. Based on the diverging points of the P A-D and P LL , we proposed a three-step method for the detection and diagnosis of RSRL.

  12. Portal monitoring for detecting fissile materials and chemical explosives

    International Nuclear Information System (INIS)

    Albright, D.

    1992-01-01

    The portal monitoring of pedestrians, packages, equipment, and vehicles entering or leaving areas of high physical security has been common for many years. Many nuclear facilities rely on portal monitoring to prevent the theft or diversion of plutonium and highly enriched uranium. At commercial airports, portals are used to prevent firearms and explosives from being smuggled onto airplanes. An August 1989 Federal Aviation Administration (FAA) regulation requires US airlines to screen luggage on international flights for chemical explosives. This paper reports that portal monitoring is now being introduced into arms-control agreements. Because some of the portal-monitoring equipment that would be useful in verifying arms-control agreements is already widely used as part of the physical security systems at nuclear facilities and commercial airports, the authors review these uses of portal monitoring, as well as its role in verifying the INF treaty. Then the authors survey the major types of portal-monitoring equipment that would be most useful in detecting nuclear warheads or fissile material

  13. Meaningful Use of a Confidential Adolescent Patient Portal.

    Science.gov (United States)

    Thompson, Lindsay A; Martinko, Thomas; Budd, Pamela; Mercado, Rebeccah; Schentrup, Anzeela M

    2016-02-01

    To design and evaluate the usage of an adolescent patient portal specifically adapted for adolescent health care needs that also satisfied institutional meaningful use guidelines regarding electronic health records. Key stakeholders at one academic health care center adopted an online portal and opted to designate a patient portal specifically for adolescents to maximize confidentiality in compliance with state privacy laws. This study analyzed aggregate electronic health record data of adolescents' (ages 12-17.9 years) uptake, usage, and functionality of this portal and compared it to parent portal usage for younger children (ages 0-11 years). Differences in means were calculated using paired t tests. The portal was used similarly between parents of young children and adolescents, with almost 1,000 enrollees in each group from September 1, 2012 to March 31, 2015. There were no gender differences in enrollment. Adolescents were less likely than parents of younger children to review appointments (73% vs. 85%), laboratory tests (67% vs. 79%), problem lists (40% vs. 78%), or allergies (45% vs. 77%, all p values adolescents sent 1,397 confidential messages. Institutional decisions for implementing meaningful use requirements can align with goals of adolescent health. Patient portals can enhance adolescent health care quality and adolescents readily use a confidential portal. Implementation of meaningful use requirements should be checked against adolescent health care needs to maximize confidentiality and promote health communication. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  14. Assessment of private hospital portals: A conceptual model

    Directory of Open Access Journals (Sweden)

    Mehdi Alipour-Hafezi

    2016-01-01

    Full Text Available Introduction: Hospital portals, as the first virtual entry, play an important role in connecting people with hospital and also presenting hospital virtual services. The main purpose of this article was to suggest a conceptual model to improve Tehran private hospital portals. The suggested model can be used by all the health portals that are in the same circumstances and all the health portals which are in progress. Method: This is a practical research, using evaluative survey research method. Research population includes all the private hospital portals in Tehran, 34 portals, and ten top international hospital portals. Data gathering tool used in this research was a researcher-made checklist including 14 criteria and 77 sub-criteria with their weight score. In fact, objective observation with the mentioned checklist was used to gather information. Descriptive statistics were used to analyze the data and tables and graphs were used to present the organized data. Also, data were analyzed using independent t-test. Conceptual modeling technique was used to design the model and demonstration method was used to evaluate the proposed model. In this regard, SPSS statistical software was used to perform the tests. Results:The comparative study between the two groups of portals, TPH and WTH, in the 14 main criteria showed that the value of t-test in contact information criteria was 0.862, portal page specification was -1.378, page design criteria -1.527, updating pages -0.322, general information and access roads -3.161, public services -7.302, patient services -4.154, patient data -8.703, research and education -9.155, public relationship -3.009, page technical specifications -4.726, telemedicine -7.488, pharmaceutical services -6.183, and financial services -2.782. Finally, the findings demonstrated that Tehran private hospital portals in criterion of contact information were favorable; page design criteria were relatively favorable; page technical

  15. A Population-Level Data Analytics Portal for Self-Administered Lifestyle and Mental Health Screening.

    Science.gov (United States)

    Zhang, Xindi; Warren, Jim; Corter, Arden; Goodyear-Smith, Felicity

    2016-01-01

    This paper describes development of a prototype data analytics portal for analysis of accumulated screening results from eCHAT (electronic Case-finding and Help Assessment Tool). eCHAT allows individuals to conduct a self-administered lifestyle and mental health screening assessment, with usage to date chiefly in the context of primary care waiting rooms. The intention is for wide roll-out to primary care clinics, including secondary school based clinics, resulting in the accumulation of population-level data. Data from a field trial of eCHAT with sexual health questions tailored to youth were used to support design of a data analytics portal for population-level data. The design process included user personas and scenarios, screen prototyping and a simulator for generating large-scale data sets. The prototype demonstrates the promise of wide-scale self-administered screening data to support a range of users including practice managers, clinical directors and health policy analysts.

  16. Management of small hepatocellular carcinoma in cirrhosis: Focus on portal hypertension

    Science.gov (United States)

    Hernandez-Gea, Virginia; Turon, Fanny; Berzigotti, Annalisa; Villanueva, Augusto

    2013-01-01

    The incidence of hepatocellular carcinoma (HCC) is rising worldwide being currently the fifth most common cancer and third cause of cancer-related mortality. Early detection of HCC through surveillance programs have enabled the identification of small nodules with higher frequency, and nowadays account for 10%-15% of patients diagnosed in the West and almost 30% in Japan. Patients with small HCC can be candidates for potential curative treatments: liver transplantation, surgical resection and percutaneous ablation, depending on the presence of portal hypertension and co-morbidities. This review will analyze recent advancements in the clinical management of these individuals, focusing on issues related to the role of portal hypertension, the debate between resection and ablative therapies and the future impact of molecular technologies. PMID:23482437

  17. Portal placement in elbow arthroscopy by novice surgeons: cadaver study.

    Science.gov (United States)

    Claessen, Femke M A P; Kachooei, Amir R; Kolovich, Gregory P; Buijze, Geert A; Oh, Luke S; van den Bekerom, Michel P J; Doornberg, Job N

    2017-07-01

    In this anatomical cadaver study, the distance between major nerves and ligaments at risk for injury and portal sites created by trainees was measured. Trainees, inexperienced in elbow arthroscopy, have received a didactic lecture and cadaver instruction prior to portal placement. The incidence of iatrogenic injury from novice portal placement was also determined. Anterolateral, direct lateral, and anteromedial arthroscopic portals were created in ten cadavers by ten inexperienced trainees in elbow arthroscopy. After creating each portal, the trajectory of the portal was marked with a guide pin. Subsequently, the cadavers were dissected and the distances between the guide pin in the anterolateral, direct lateral, and anteromedial portals and important ligaments and nerves were measured. The difference between the distance of the direct lateral portal and the posterior antebrachial cutaneous nerve (PABCN) (22 mm, p cadaver instruction session alone. Level of evidence V.

  18. Radiation therapists' perceptions of the minimum level of experience required to perform portal image analysis

    International Nuclear Information System (INIS)

    Rybovic, Michala; Halkett, Georgia K.; Banati, Richard B.; Cox, Jennifer

    2008-01-01

    Background and purpose: Our aim was to explore radiation therapists' views on the level of experience necessary to undertake portal image analysis and clinical decision making. Materials and methods: A questionnaire was developed to determine the availability of portal imaging equipment in Australia and New Zealand. We analysed radiation therapists' responses to a specific question regarding their opinion on the minimum level of experience required for health professionals to analyse portal images. We used grounded theory and a constant comparative method of data analysis to derive the main themes. Results: Forty-six radiation oncology facilities were represented in our survey, with 40 questionnaires being returned (87%). Thirty-seven radiation therapists answered our free-text question. Radiation therapists indicated three main themes which they felt were important in determining the minimum level of experience: 'gaining on-the-job experience', 'receiving training' and 'working as a team'. Conclusions: Radiation therapists indicated that competence in portal image review occurs via various learning mechanisms. Further research is warranted to determine perspectives of other health professionals, such as radiation oncologists, on portal image review becoming part of radiation therapists' extended role. Suitable training programs and steps for implementation should be developed to facilitate this endeavour

  19. Clinical significance of neonatal menstruation.

    Science.gov (United States)

    Brosens, Ivo; Benagiano, Giuseppe

    2016-01-01

    Past studies have clearly shown the existence of a spectrum of endometrial progesterone responses in neonatal endometrium, varying from proliferation to full decidualization with menstrual-like shedding. The bleedings represent, similar to what occurs in adult menstruation, a progesterone withdrawal bleeding. Today, the bleeding is completely neglected and considered an uneventful episode of no clinical significance. Yet clinical studies have linked the risk of bleeding to a series of events indicating fetal distress. The potential link between the progesterone response and major adolescent disorders requires to be investigated by prospective studies. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Comparison of Technical and Clinical Outcome of Transjugular Portosystemic Shunt Placement Between a Bare Metal Stent and a PTFE-Stentgraft Device.

    Science.gov (United States)

    Lauermann, J; Potthoff, A; Mc Cavert, M; Marquardt, S; Vaske, B; Rosenthal, H; von Hahn, T; Wacker, F; Meyer, B C; Rodt, Thomas

    2016-04-01

    To analyse technical and clinical success of transjugular intrahepatic portosystemic shunt (TIPS) in patients with portal hypertension and compare a stent and a stentgraft with regard to clinical and technical outcome and associated costs. 170 patients (56 ± 12 years, 32.9% females) treated with TIPS due to portal hypertension were reviewed. 80 patients received a stent (group 1) and 83 a stentgraft (group 2), and seven interventions were unsuccessful. Technical data, periprocedural imaging, follow-up ultrasound and clinical data were analysed with focus on technical success, patency, clinical outcome and group differences. Cost analysis was performed. Portal hypertension was mainly caused by ethyltoxic liver cirrhosis with ascites as dominant symptom (80%). Technical success was 93.5% with mean portosystemic gradient decrease from 16.1 ± 4.8 to 5.1 ± 2.1 mmHg. No significant differences in technical success and portosystemic gradient decrease between the groups were observed. Kaplan-Meier analysis yielded significant differences in primary patency after 14 days, 6 months and 2 years in favour of the stentgraft. Both groups showed good clinical results without significant difference in 1-year survival and hepatic encephalopathy rate. Costs to establish TIPS and to manage 2-year follow-up with constant patency and clinical success were 8876 € (group 1) and 9394 € (group 2). TIPS is a safe and effective procedure to manage portal hypertension. Stent and stentgraft enabled good technical and clinical results with a low complication rate. Primary patency rates are clearly in favour of the stentgraft, whereas the stent was more cost effective with similar clinical results in both groups.

  1. Portal Hypertension Secondary to Spontaneous Arterio-Portal Venous Fistulas: Transcatheter Arterial Embolization with n-Butyl Cyanoacrylate and Microcoils

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Nakamura, Toshiyuki; Nishimura, Tsunehiko

    2000-01-01

    We report a 73-year-old man with recurrent variceal bleeding due to portal hypertension caused by multiple intrahepatic arterio-portal venous fistulas, which were successfully occluded by embolization with n-butyl cyanoacrylate and micro-coils

  2. The Portals 4.1 Network Programming Interface

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Brian; Brightwell, Ronald B.; Grant, Ryan; Hemmert, Karl Scott; Pedretti, Kevin; Wheeler, Kyle; Underwood, Keith D; Riesen, Rolf; Maccabe, Arthur B.; Hudson, Trammel

    2017-04-01

    This report presents a specification for the Portals 4 networ k programming interface. Portals 4 is intended to allow scalable, high-performance network communication betwee n nodes of a parallel computing system. Portals 4 is well suited to massively parallel processing and embedded syste ms. Portals 4 represents an adaption of the data movement layer developed for massively parallel processing platfor ms, such as the 4500-node Intel TeraFLOPS machine. Sandia's Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4 is tar geted to the next generation of machines employing advanced network interface architectures that support enh anced offload capabilities.

  3. The Portals 4.0 network programming interface.

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Brian W.; Brightwell, Ronald Brian; Pedretti, Kevin; Wheeler, Kyle Bruce; Hemmert, Karl Scott; Riesen, Rolf E.; Underwood, Keith Douglas; Maccabe, Arthur Bernard; Hudson, Trammell B.

    2012-11-01

    This report presents a specification for the Portals 4.0 network programming interface. Portals 4.0 is intended to allow scalable, high-performance network communication between nodes of a parallel computing system. Portals 4.0 is well suited to massively parallel processing and embedded systems. Portals 4.0 represents an adaption of the data movement layer developed for massively parallel processing platforms, such as the 4500-node Intel TeraFLOPS machine. Sandias Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4.0 is targeted to the next generation of machines employing advanced network interface architectures that support enhanced offload capabilities.

  4. Computed tomographic evaluation of the portal vein in the hepatomas

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kee Hyung; Lee, Seung Chul; Bae, Man Gil; Seo, Heung Suk; Kim, Soon Yong; Lee, Min Ho; Kee, Choon Suhk; Park, Kyung Nam [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    1986-10-15

    Computed tomography and pornographic findings of 63 patients with hepatoma, undergone hepatic angiography and superior mesenteric pornography for evaluation of tumor and thrombosis of portal vein and determination of indication of transcatheter arterial embolization for palliative treatment of hepatoma from April, 85 to June, 86 in Hanyang university hospital, were reviewed. The results were as follows: 1. In 36 cases, portal vein thrombosis was detected during photography. Nineteen of 37 cases which revealed localized hepatoma in the right lobe of the liver showed portal vein thrombosis; 9 of 11 cases of the left lobe; 8 of 14 cases which were involved in entire liver revealed thrombosis. One case localized in the caudate lobe showed no evidence of invasion to portal vein. 2. Twenty-four of 34 cases with diffuse infiltrative hepatoma revealed portal vein thrombosis and the incidence of portal vein thrombosis in this type were higher than in the cases of the nodular type. 3. The portal vein thrombosis appeared as filling defects of low density in the lumen of the portal veins in CT and they did not reveal contrast enhancement. 4. CT revealed well the evidence of obstructions in the cases of portal vein thrombosis and the findings were well-corresponded to the findings of the superior mesenteric photography. 5. Five of the cases of the portal vein thrombosis were missed in the CT and the causes were considered as due to partial volume effect of enhanced portal vein with partial occlusion or arterioportal shunts. 6. Six of 13 cases with occlusion of main portal vein showed cavernous transformation and they were noted as multiple small enhanced vascularities around the porta hepatis in the CT. According to the results, we conclude that CT is a useful modality to detect the changes of the portal veins in the patients of the hepatoma.

  5. Computed tomographic evaluation of the portal vein in the hepatomas

    International Nuclear Information System (INIS)

    Lee, Kee Hyung; Lee, Seung Chul; Bae, Man Gil; Seo, Heung Suk; Kim, Soon Yong; Lee, Min Ho; Kee, Choon Suhk; Park, Kyung Nam

    1986-01-01

    Computed tomography and pornographic findings of 63 patients with hepatoma, undergone hepatic angiography and superior mesenteric pornography for evaluation of tumor and thrombosis of portal vein and determination of indication of transcatheter arterial embolization for palliative treatment of hepatoma from April, 85 to June, 86 in Hanyang university hospital, were reviewed. The results were as follows: 1. In 36 cases, portal vein thrombosis was detected during photography. Nineteen of 37 cases which revealed localized hepatoma in the right lobe of the liver showed portal vein thrombosis; 9 of 11 cases of the left lobe; 8 of 14 cases which were involved in entire liver revealed thrombosis. One case localized in the caudate lobe showed no evidence of invasion to portal vein. 2. Twenty-four of 34 cases with diffuse infiltrative hepatoma revealed portal vein thrombosis and the incidence of portal vein thrombosis in this type were higher than in the cases of the nodular type. 3. The portal vein thrombosis appeared as filling defects of low density in the lumen of the portal veins in CT and they did not reveal contrast enhancement. 4. CT revealed well the evidence of obstructions in the cases of portal vein thrombosis and the findings were well-corresponded to the findings of the superior mesenteric photography. 5. Five of the cases of the portal vein thrombosis were missed in the CT and the causes were considered as due to partial volume effect of enhanced portal vein with partial occlusion or arterioportal shunts. 6. Six of 13 cases with occlusion of main portal vein showed cavernous transformation and they were noted as multiple small enhanced vascularities around the porta hepatis in the CT. According to the results, we conclude that CT is a useful modality to detect the changes of the portal veins in the patients of the hepatoma.

  6. Dynamic CT and MRA findings of a case of portopulmonary venous anastomosis (PPVA) in a patient with portal hypertension: a case report and review of the literature

    International Nuclear Information System (INIS)

    Ko, Jeong Min; Ahn, Myeong Im; Han, Dae Hee; Jung, Jung Im; Park, Seog Hee

    2011-01-01

    Portopulmonary venous anastomosis (PPVA), which has been rarely reported in conventional CT and MR studies, is an unusual collateral pathway in patients with portal hypertension. It has clinical implications related to right-to-left shunt that are different from the clinical implications related to other more usual portosystemic shunts in portal hypertensive patients. Here, we report the dynamic CT and MRA findings of a case of PPVA in a patient with portal hypertension, directly demonstrating the shunt flow from the paraesophageal varix to the left atrium via the right inferior pulmonary vein

  7. Dynamic CT and MRA findings of a case of portopulmonary venous anastomosis (PPVA) in a patient with portal hypertension: a case report and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Jeong Min; Ahn, Myeong Im; Han, Dae Hee; Jung, Jung Im; Park, Seog Hee (Dept. of Radiology, Seoul St Mary' s Hospital, College of Medicine, The Catholic Univ. of Korea, Seoul (Korea, Republic of)), email: ami@catholic.ac.kr

    2011-06-15

    Portopulmonary venous anastomosis (PPVA), which has been rarely reported in conventional CT and MR studies, is an unusual collateral pathway in patients with portal hypertension. It has clinical implications related to right-to-left shunt that are different from the clinical implications related to other more usual portosystemic shunts in portal hypertensive patients. Here, we report the dynamic CT and MRA findings of a case of PPVA in a patient with portal hypertension, directly demonstrating the shunt flow from the paraesophageal varix to the left atrium via the right inferior pulmonary vein

  8. Base of tongue varices associated with portal hypertension

    OpenAIRE

    Jassar, P; Jaramillo, M; Nunez, D

    2000-01-01

    A symptomatic case of tongue base varices in a patient with portal hypertension secondary to liver cirrhosis is presented. There are no previously documented cases in the world literature. Oesophageal varices may not be the only source of expectorated blood in a patient with portal hypertension.


Keywords: portal hypertension; lingual; tongue; varicose vein

  9. Analysis of Dynamic Characteristics of Portal Frame with Variable Section

    OpenAIRE

    Hao Jianing

    2016-01-01

    Combined with a portal frame design, by the use of finite element software ANSYS, the finite element model of single specimens of portal rigid frame and the overall portal rigid frame building are established. portal rigid frame’s beam and column is variable cross section. Through the modal analysis, comparative analysis of the frequency and vibration type of the radiolabeling specimens and finite element model of the whole, for the further development of variable cross-section portal rigid f...

  10. Era of liver transplantation: combined anatomic splenectomy and anticoagulant therapy in prevention of portal vein thrombosis after splenectomy.

    Science.gov (United States)

    Hongwei, Chen; Zhang, Liang; Maoping, Li; Yong, Zhang; Chengyou, Du; Dewei, Li

    2015-01-01

    Portal vein thrombosis (PVT) is a common complication following splenectomy in patients with liver cirrhosis and portal hypertension, which also brings difficulties to future possible liver transplantation. This paper retrospectively analyzes the preventive effect of combined anatomic splenectomy and early anticoagulant therapy on post-splenectomy portal vein thrombosis in patients with portal hypertension. We retrospectively analyzed 136 patients who underwent splenectomy at our hospital between January 2010 and December 2013 due to liver cirrhosis and portal hypertension. Patient conditions, such as coagulation function, splenic and portal vein thrombosis, intra-abdominal hemorrhage, pancreatic leakage and intra-abdominal infections, are observed postoperatively. Despite the presence of liver cirrhosis and portal hypertension in patients, early postoperative anticoagulant therapy has no significant impact on coagulation function and intra-abdominal hemorrhage of these patients (p > 0.05). Anatomic splenectomy can reduce the occurrence of complications such as postoperative bleeding, pancreatic leakage and intra-abdominal infections (p splenectomy and early postoperative anticoagulant therapy can reduce post-splenectomy portal vein thrombosis in patients with portal hypertension, and is conducive to the future liver transplantation therapy may be needed by the patients.

  11. A user-oriented model for global enterprise portal design

    NARCIS (Netherlands)

    Feng, X.; Ehrenhard, Michel Léon; Hicks, Jeff; Maathuis, Stephanus Johannes; Maathuis, S.J.; Hou, Y.

    2010-01-01

    Enterprise portals collect and synthesise information from various systems to deliver personalised and highly relevant information to users. Enterprise portals' design and applications are widely discussed in the literature; however, the implications of portal design in a global networked

  12. Combination of TIPSS and azygoportal disconnection for portal hypertension

    International Nuclear Information System (INIS)

    Cao Jianmin; Wu Xingjiang; Han Jianming; Wu Xuehao; Li Jieshou

    2002-01-01

    Objective: To investigate the clinical results of combined TIPSS and azygoportal disconnection for portal hypertension in controlling and preventing esophageal variceal bleeding. Methods: From Oct. 1996 to Dec. 2001, 60 patients with portal hypertension were admitted to authors' department because of variceal bleeding and submitted to the treatment with the combination TIPSS and azygoportal disconnection. According to Child-Pugh classification, 11 patients were in class A, 37 in class B, and 12 in class C. 41 patients showed mild ascites and 8 with severe ascites. The mild and severe esophageal varices were proven by upper digestive barium meal. The procedure was divided into two stages; first, TIPSS procedure with the stent of diameter 0.8 cm and length 6-7 cm was successfully in planted in all patients, second, all patients underwent azygoportal disconnection two weeks later after TIPSS. Results: After the combination TIPSS and azygoportal disconnection, the recent complications included three cases with bleeding at operative fields, one case with infradiaphragmatic abscess and seven with slight encephalopathy. No rebleeding of esophageal varices and death occurred during the treatment. During the follow-up of 1-5 years, the rates of shunt occlusion, rebleeding and death were 11.9%, 3.5% and 7.0% respectively. Conclusions: The combination TIPSS and azygoportal disconnection is an efficient therapeutic methods for portal hypertension

  13. Leptin receptor blockade reduces intrahepatic vascular resistance and portal pressure in an experimental model of rat liver cirrhosis.

    Science.gov (United States)

    Delgado, María Gabriela; Gracia-Sancho, Jordi; Marrone, Giusi; Rodríguez-Vilarrupla, Aina; Deulofeu, Ramon; Abraldes, Juan G; Bosch, Jaume; García-Pagán, Juan Carlos

    2013-10-01

    Increased hepatic vascular resistance mainly due to elevated vascular tone and to fibrosis is the primary factor in the development of portal hypertension in cirrhosis. Leptin, a hormone associated with reduction in nitric oxide bioavailability, vascular dysfunction, and liver fibrosis, is increased in patients with cirrhosis. We aimed at evaluating whether leptin influences the increased hepatic resistance in portal hypertension. CCl4-cirrhotic rats received the leptin receptor-blocker ObR antibody, or its vehicle, every other day for 1 wk. Hepatic and systemic hemodynamics were measured in both groups. Hepatic nitric oxide production and bioavailability, together with oxidative stress, nitrotyrosinated proteins, and liver fibrosis, were evaluated. In cirrhotic rats, leptin-receptor blockade significantly reduced portal pressure without modifying portal blood flow, suggesting a reduction in the intrahepatic resistance. Portal pressure reduction was associated with increased nitric oxide bioavailability and with decreased O2(-) levels and nitrotyrosinated proteins. No changes in systemic hemodynamics and liver fibrosis were observed. In conclusion, the present study shows that blockade of the leptin signaling pathway in cirrhosis significantly reduces portal pressure. This effect is probably due to a nitric oxide-mediated reduction in the hepatic vascular tone.

  14. Portal venous gas detected on computed tomography in emergency situations: surgery is still necessary.

    Science.gov (United States)

    Monneuse, Olivier; Pilleul, Frank; Barth, Xavier; Gruner, Laurent; Allaouchiche, Bernard; Valette, Pierre-Jean; Tissot, E

    2007-05-01

    Portal venous gas (PVG) has been reported to be associated with lethal surgical diagnosis. Recent studies tend to confirm the clinical significance of gas in the portal vein; however, some patients are managed without surgical treatment. The aim of this study was to assess both the diagnoses and the treatment of patients with PVG in an emergency surgical setting. We performed a retrospective chart review of 15 patients with PVG in the emergency setting detected by computed tomography (CT) between July 1999 and July 2004. Characteristics assessed included age, sex, clinical presentation, first CT diagnosis of both PVG and the underlying pathology, American Society of Anesthesiologists (ASA) score, surgical findings, final clinical diagnosis, duration of hospitalization, and evolution of the illness/mortality. All patients were examined one month after operation. This series of 5 women and 10 men ranged in age from 38 to 90 years at the time they underwent emergency surgical treatment. The mean preoperative ASA score was 4.20. Computed tomography diagnosed the underlying pathology in all cases: bowel obstruction (4 cases), bowel necrosis (9 cases), and diffuse peritonitis (2 cases). The mean length of hospital stay was 12.4 days. The mortality rate was 46.6%; (7 patients). A wide range of pathologies can generate PVG. Computed tomography can detect both the presence of gas and the underlying pathology. In emergency situations, all the diagnosed causal pathologies required a surgical procedure without delay. We report that the prognosis was related to the pathology itself and was not influenced by the presence of PVG.

  15. Nuclear Instrumentation Module (NIM) standard logic processor as a portal signal analyzer

    International Nuclear Information System (INIS)

    Minges, G.P.

    1978-01-01

    A general purpose electronic logic processor has been designed into a 2 wide NIM (Nuclear Instrumentation Module) bin module. The unit utilizes a microprocessor to achieve necessary versatility. The processor's first use is as a new generation signal analyzer for use in radiometric personnel and vehicle portal monitors. Significant improvements have been obtained in sensitivity and stability over existing analog discriminators. The new analyzer is presently being used to update personnel and vehicle portal monitoring systems

  16. Noncirrhotic portal fibrosis after Wilms' tumor therapy

    International Nuclear Information System (INIS)

    Barnard, J.A.; Marshall, G.S.; Neblett, W.W.; Gray, G.; Ghishan, F.K.

    1986-01-01

    A 9-yr-old girl developed massive hemorrhage from esophageal varices 2 yr after combined modality therapy for Wilms' tumor. Evaluation showed a patent extrahepatic portal venous system and an elevated splenic pulp pressure. In contrast to previous reports of hepatopathy after irradiation injury, histologic sections of the liver did not demonstrate occlusion of the central veins, but rather a diffuse obliteration of intrahepatic portal venous radicles. This pattern of noncirrhotic portal fibrosis has not been described following antitumor therapy

  17. Portal circulation aneurysms: two case reviews

    International Nuclear Information System (INIS)

    Perret, W. L.; Silva, A de.; Elzarka, A.; Schelleman, A.

    2007-01-01

    Venous aneurysms of the superior mesenteric vein and portal vein are an uncommon occurrence and often an incidental finding. They can also be associated with hepatocellular disease and portal hypertension. We present CT and ultrasound findings of these entities. The management of venous aneurysms is generally conservative with serial imaging

  18. On the usefulness of portal monitor unit subtraction in radiation therapy

    International Nuclear Information System (INIS)

    Kuperman, Vadim Y; Lubich, Leslie M

    2003-01-01

    In order to avoid additional dose to patients caused by portal imaging with megavoltage x-rays, portal monitor units (MUs) are frequently subtracted from the actual treatment MUs. This study examines the usefulness of portal MU subtraction in radiation therapy. For 11 prostate cancer patients treated with 23 MV photons, dose to prostate due to portal filming with 6 MV photons was determined. In all 11 patients subtraction of portal MU values from the actual treatment MUs resulted in a small underdosing of the prostate with an average treatment error of -0.5%. Portal filming without MU subtraction would cause small overdosing of the prostate with an average treatment error of 1.2%. The results of this study indicate that the benefits of portal MU subtraction are in doubt if (a) the energy of treatment x-rays is much higher than that of the portal x-rays and/or (b) when radiotherapy is performed with physical wedges. Based on the obtained results, we argue against unconditional use of the portal MU subtraction method to eliminate the dose from portal imaging

  19. Treatment portals for elective radiotherapy of the neck: an inventory in The Netherlands

    International Nuclear Information System (INIS)

    Nowak, Peter; Dieren, Erik van; Soernsen de Koste, John van; Est, Henry van der; Heijmen, Ben; Levendag, Peter

    1997-01-01

    Purpose: To assess the variation in and the three-dimensional dosimetric consequences of treatment portals for elective neck irradiation. Materials and methods: Radiation oncologists (n = 16) from all major Head and Neck Co-operative Groups in The Netherlands (n = 11) were asked to delineate treatment portals on a lateral and an anterior simulation film in case of elective neck irradiation for a T3N0 tumour of the supraglottic larynx and a T2N0 tumour of the mobile tongue. In addition, they had to define their target, i.e. which parts of the neck nodal regions they would choose to irradiate electively for these particular tumour sites. Subsequently, treatment portals were compared and evaluated using CT-data and a 3-dimensional (3D) treatment planning system. Results: Significant variations were found in the shapes and sizes of the applied treatment techniques and portals. Also, among radiation oncologists who elected to irradiate the same lymph node regions, a significant variation in the delineated treatment portals was observed. As a consequence, substantial variations in treated volumes and in calculated normal tissue complication probabilities (NTCPs) for the parotid- and submandibular glands were observed. Conclusion: For the tumour sites studied there appears to be a lack of standardisation in the areas of the neck to be irradiated electively. The observed differences may have consequences for the ultimate failure rate and particularly with regard to the side effects, e.g. the degree of xerostomia. It is argued that in the near future a more precise three-dimensional definition on CT of the lymph node regions in the neck might allow for a better standardisation of the treatment portals and, in addition, for the development and application of conformal radiotherapy techniques for optimal sparing of the critical normal tissues (e.g. parotid- and submandibular glands) with maximum tumour control probability

  20. Portfolio: a prototype workstation for development and evaluation of tools for analysis and management of digital portal images

    International Nuclear Information System (INIS)

    Boxwala, Aziz A.; Chaney, Edward L.; Fritsch, Daniel S.; Friedman, Charles P.; Rosenman, Julian G.

    1998-01-01

    Purpose: The purpose of this investigation was to design and implement a prototype physician workstation, called PortFolio, as a platform for developing and evaluating, by means of controlled observer studies, user interfaces and interactive tools for analyzing and managing digital portal images. The first observer study was designed to measure physician acceptance of workstation technology, as an alternative to a view box, for inspection and analysis of portal images for detection of treatment setup errors. Methods and Materials: The observer study was conducted in a controlled experimental setting to evaluate physician acceptance of the prototype workstation technology exemplified by PortFolio. PortFolio incorporates a windows user interface, a compact kit of carefully selected image analysis tools, and an object-oriented data base infrastructure. The kit evaluated in the observer study included tools for contrast enhancement, registration, and multimodal image visualization. Acceptance was measured in the context of performing portal image analysis in a structured protocol designed to simulate clinical practice. The acceptability and usage patterns were measured from semistructured questionnaires and logs of user interactions. Results: Radiation oncologists, the subjects for this study, perceived the tools in PortFolio to be acceptable clinical aids. Concerns were expressed regarding user efficiency, particularly with respect to the image registration tools. Conclusions: The results of our observer study indicate that workstation technology is acceptable to radiation oncologists as an alternative to a view box for clinical detection of setup errors from digital portal images. Improvements in implementation, including more tools and a greater degree of automation in the image analysis tasks, are needed to make PortFolio more clinically practical

  1. Evaluation of Portal Venous Velocity with Doppler Ultrasound in Patients with Nonalcoholic Fatty Liver Disease

    Energy Technology Data Exchange (ETDEWEB)

    Ulusan, Serife; Yakar, Tolga; Koc, Zafer [Baskent University Faculty of Medicine, Adana (Turkmenistan)

    2011-08-15

    We examined the relationship between portal venous velocity and hepatic-abdominal fat in patients with nonalcoholic fatty liver disease (NAFLD), using spectral Doppler ultrasonography (US) and magnetic resonance imaging (MRI). In this prospective study, 35 patients with NAFLD and 29 normal healthy adults (control group) underwent portal Doppler US. The severity of hepatic steatosis in patients with NAFLD was assessed by MRI through chemical shift imaging, using a modification of the Dixon method. Abdominal (intra-abdominal and subcutaneous) fat was measured by MRI. The difference in portal venous velocity between the patients with NAFLD and the control group was significant (p < 0.0001). There was no correlation between the degree of abdominal or hepatic fat and portal venous velocity (p > 0.05). There were strong correlations between the hepatic fat fraction and subcutaneous adiposity (p < 0.0001), intraperitoneal fat accumulation (p 0.017), and retroperitoneal fat accumulation (p < 0.0001). Our findings suggest that patients with NAFLD have lower portal venous velocities than normal healthy subjects.

  2. Effects of albendazole nanoparticles in mice with hepatic echinococosis: Portal vein cannulation versus intravenous administration.

    Science.gov (United States)

    Zhu, Di-Wen; Zhang, Ming-Xing; Bao, Ying-Jun; Gu, Jun-Peng; Ji, Wei-Zheng; Zhang, Hai-Xiao; Ren, Wei-Xin

    2015-07-01

    To compare the ABZ and its metabolites concentration in cyst tissue of hepatic alveolar echinococcosis administered by different routes, forty male Wistar rats receiving albendazole nanoparticles from tail vein and portal vein were divided into two groups, the concentration of ABZ and its metabolites ABZSO, ABZSO2, in the cyst tissue, were analyzed by HPLC at 2, 4, 8, 24, 36 h after administration. The parent drug and its metabolites were detected in plasm and the cyst tissue after portal cannulation and intravenous administration. The last results were the concentration of ABZ in the portal cannulation group was higher than in the intravenous group at every time point (p < 0.05). Compared to the intravenous group, the portal cannulation administration of ABZ led to a lower plasm concentration of ABZ. The concentration of ABZ and the active ABZSO were significantly higher in the portal cannulation group than that of the intravenous group. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Symptomatic portal vein occlusion: treated by interventional radiological techniques

    International Nuclear Information System (INIS)

    Wang Maoqiang; Gu Xiaofang; Guan Jun; Wang Zhongpu; Liu Fengyong; Wang Zhiqiang

    2004-01-01

    Objective: To evaluate the efficacy and safety of the interventional radiological techniques for management of symptomatic portal vein (PV) occlusion. Methods: Nine patients with PV trunk occlusion were treated using interventional procedures. Four patients presented with abdominal pain, distention, and malabsorption; five presented with portal hypertension and repeated bleeding from esophagogastric varices. The etiologic factors were identified in all 9 patients, including post-transplantation of the liver in 2, hepatocellular carcinoma (HCC) associated with PV tumor thrombus in 3, post abdominal operative state in 1, and PV thrombosis in 3 cases. The portal access was established via a percutaneous transhepatic route in 4, and via a transjugular intrahepatic portosystemic shunt ( TIPS) approach in 5 patients. The interventional procedures included stent placement in 4, balloon angioplasty in 6, and catheter directed pharmacologic and mechanical thrombolysis in 7 patients. Results: The technical success was achieved in all cases. No complications related to the procedure occurred. Portal flow was reestablished in all patients after the procedures. Clinical improvement was seen in 3 patients with symptomatic PV thrombosis, characterized by progressive reduction of abdominal pain, distention, and diarrhea. Follow-up time ranged from 4 to 36 months. One patient with HCC died of multiple organs metastases at 11 months after the treatment . One patient died of intraabdominal sepsis and multiple organs failure 12 days after the procedure even though the antegrade flow was re-established in the main trunk of the PV. Patency of the PV trunk was confirmed by follow-up color Doppler ultrasound scan in the rest 7 patients, without recurrence of variceal bleeding or PV thrombus. Conclusions: Interventional minimally invasive procedures, including balloon angioplasty, stent placement, catheter directed local pharmacologic and mechanical thrombolysis, are safe and effective in

  4. Clinical significance of anismus in encopresis.

    Science.gov (United States)

    Catto-Smith, A G; Nolan, T M; Coffey, C M

    1998-09-01

    Treatments designed to relieve paradoxical contraction of the anal sphincters during defecation (anismus) have had limited success in children with encopresis. This has raised doubts as to the clinical relevance of this diagnosis in childhood as anorectal dysfunction. Our aim was to determine whether, in patients who had treatment-resistant encopresis, the presence of electromyographic anismus was associated with increased faecal retention. Sixty-eight children with soiling (mean age 8.7+/-2.06 years) were assessed by clinical examination, abdominal radiography and then with anorectal manometry. Patients with electromyographic anismus (n=32; 47%) had significantly increased radiographic rectal faecal retention and were significantly less likely to be able to defecate water-filled balloons. There were no significant differences in response to prior therapy, history of primary encopresis, behavioural adjustment or in sociodemographic data. Our results suggest that electromyographic anismus is associated with obstructed defecation and faecal retention.

  5. Algorithms for contrast enhancement of electronic portal images

    International Nuclear Information System (INIS)

    Díez, S.; Sánchez, S.

    2015-01-01

    An implementation of two new automatized image processing algorithms for contrast enhancement of portal images is presented as suitable tools which facilitate the setup verification and visualization of patients during radiotherapy treatments. In the first algorithm, called Automatic Segmentation and Histogram Stretching (ASHS), the portal image is automatically segmented in two sub-images delimited by the conformed treatment beam: one image consisting of the imaged patient obtained directly from the radiation treatment field, and the second one is composed of the imaged patient outside it. By segmenting the original image, a histogram stretching can be independently performed and improved in both regions. The second algorithm involves a two-step process. In the first step, a Normalization to Local Mean (NLM), an inverse restoration filter is applied by dividing pixel by pixel a portal image by its blurred version. In the second step, named Lineally Combined Local Histogram Equalization (LCLHE), the contrast of the original image is strongly improved by a Local Contrast Enhancement (LCE) algorithm, revealing the anatomical structures of patients. The output image is lineally combined with a portal image of the patient. Finally the output images of the previous algorithms (NLM and LCLHE) are lineally combined, once again, in order to obtain a contrast enhanced image. These two algorithms have been tested on several portal images with great results. - Highlights: • Two Algorithms are implemented to improve the contrast of Electronic Portal Images. • The multi-leaf and conformed beam are automatically segmented into Portal Images. • Hidden anatomical and bony structures in portal images are revealed. • The task related to the patient setup verification is facilitated by the contrast enhancement then achieved.

  6. Ultrasound and Doppler examination capabilities in adult portal hypertension type definition

    Directory of Open Access Journals (Sweden)

    N. V. Tumanskaya

    2015-08-01

    Full Text Available Early portal hypertension type diagnostics is an ultimate factor concerning kind and tactics of treatment. Aim. To objectify ultrasound examination capabilities, portal hemodynamics were studied in 97 patients using impulse and color doppler. Methods and results. It was ascertained that impulse and color doppler examination allows to visualize portal vein and its branches’ structural abnormalities, define subhepatic and intrahepatic types of portal hypertension, find thrombosis and characterize its stages. In cirrhosis patients with portal hypertension, homogenous doppler signal was received from the portal vessels lumen, while signs of intraluminar pathology were seen in the case of thrombosis of portal vein. Conclusion. This means that ultrasound examination of portal vein and its branches with impulse and color doppler is informative, non invasive method, which helps to define stages of portal hypertension. Doppler ultrasonography doesn’t have negative effect of ionizing radiation and can be used for the repeated research in the dynamics of disease.

  7. Efficacy of endoscopic histoacryl injection in treatment of gastric variceal bleeding caused by regional portal hypertension

    Directory of Open Access Journals (Sweden)

    TANG Shanhong

    2015-08-01

    Full Text Available Objective To analyze the efficacy of endoscopic histoacryl injection in the treatment of gastric variceal bleeding caused by regional portal hypertension. Methods The endoscopic features and efficacy of endoscopic histoacryl injection were examined and compared in two groups of patients admitted to our hospital from June 2012 to December 2012. One of the groups included 6 patients with gastric variceal bleeding caused by regional portal hypertension and the other group included 6 patients with gastric variceal bleeding caused by hepatitis B cirrhosis-related portal hypertension. Between-group comparison of categorical data was made by Fisher′s test. Results In patients with regional portal hypertension, five of them had severe isolated gastric varices (IGV and one had severe IGV with mild esophageal varices. All six patients with hepatitis B cirrhosis-related portal hypertension had severe IGV and the endoscopic features were similar to those of patients with regional portal hypertension. Significant differences were observed between the group with regional portal hypertension and the group with hepatitis B cirrhosis related portal hypertension in short-term response rate (1/6 vs 6/6, P=0.015 and long-term response rate (0/6 vs 5/6, P=0.015. Conclusion The gastric varices caused by regional portal hypertension has a fast progression rate and a high bleeding risk. The efficacy of endoscopic histoacryl injection in patients with this type of gastric varices is poor.

  8. The thresholds for statistical and clinical significance

    DEFF Research Database (Denmark)

    Jakobsen, Janus Christian; Gluud, Christian; Winkel, Per

    2014-01-01

    BACKGROUND: Thresholds for statistical significance are insufficiently demonstrated by 95% confidence intervals or P-values when assessing results from randomised clinical trials. First, a P-value only shows the probability of getting a result assuming that the null hypothesis is true and does...... not reflect the probability of getting a result assuming an alternative hypothesis to the null hypothesis is true. Second, a confidence interval or a P-value showing significance may be caused by multiplicity. Third, statistical significance does not necessarily result in clinical significance. Therefore...... of the probability that a given trial result is compatible with a 'null' effect (corresponding to the P-value) divided by the probability that the trial result is compatible with the intervention effect hypothesised in the sample size calculation; (3) adjust the confidence intervals and the statistical significance...

  9. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yongwonn [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Park, Hee Sun, E-mail: heesun.park@gmail.com [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Kim, Young Jun; Jung, Sung Il; Jeon, Hae Jeong [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of)

    2012-08-15

    Objective: The purpose of this study is to evaluate the question of whether nonenhanced CT or contrast enhanced portal phase CT can replace multiphasic pancreas protocol CT in short term monitoring in patients with acute pancreatitis. Materials and methods: This retrospective study was approved by the Institutional Review Board. From April 2006 to May 2010, a total of 52 patients having acute pancreatitis who underwent initial dual phase multidetector row CT (unenhanced, arterial, and portal phase) at admission and a short term (within 30 days) follow up dual phase CT (mean interval 10.3 days, range 3-28 days) were included. Two abdominal radiologists performed an independent review of three sets of follow up CT images (nonenhanced scan, single portal phase scan, and dual phase scan). Interpretation of each image set was done with at least 2-week interval. Radiologists evaluated severity of acute pancreatitis with regard to pancreatic inflammation, pancreatic necrosis, and extrapancreatic complication, based on the modified CT severity index. Scores of each image set were compared using a paired t-test and interobserver agreement was evaluated using intraclass correlation coefficient statistics. Results: Mean scores of sum of CT severity index on nonenhanced scan, portal phase scan, and dual phase scan were 5.7, 6.6, and 6.5 for radiologist 1, and 5.0, 5.6, and 5.8 for radiologist 2, respectively. In both radiologists, contrast enhanced scan (portal phase scan and dual phase scan) showed significantly higher severity score compared with that of unenhanced scan (P < 0.05), while portal phase and dual phase scan showed no significant difference each other. The trend was similar regarding pancreatic inflammation and extrapancreatic complications, in which contrast enhanced scans showed significantly higher score compared with those of unenhanced scan, while no significant difference was observed between portal phase scan and dual phase scan. In pancreatic necrosis

  10. Interactive monitoring portal for fusion simulations

    International Nuclear Information System (INIS)

    Abla, G.; Schissel, D.P.; Kim, E.N.; Flanagan, S.M.; Lee, X.

    2012-01-01

    Highlights: ► We designed a web-based monitoring system that tracks the status of fusion simulations. ► Our system is scalable to monitor the simulations running on distributed supercomputers and clusters located at multiple geographical locations. ► The monitoring portal provides a web-based interface for post-run analysis, such as visualizing the results, logging the user comments, and rating the simulation quality. ► Our system utilizes the open source software, such as Python, Django, MySQL, Apache, and MDSplus. - Abstract: The Center for Simulation of RF Wave Interactions with Magnetohydrodynamics (SWIM) Project is a proto-Fusion Simulation Program (FSP) whose goal is to study high-performance fusion plasmas and perform comprehensive simulations that are essential to the development of fusion. SWIM team members are geographically distributed and utilize distributed supercomputers for computational simulations. Due to the highly distributed computational work environment, the SWIM team has the difficulty of monitoring code runs and discovering historical runs. To alleviate this difficulty a web-based monitoring portal has been developed and deployed. The monitoring portal tracks the progress of simulations and automatically collects metadata in real-time. This capability helps scientists to effectively utilize precious computer resources. Furthermore, the portal provides a web-based interface for post-run analysis, such as visualizing the results, logging the user comments, and rating the simulation quality. The user interface provides rapid discovery capability via multi-field searching and sorting. The development of the monitoring portal used open source software, such as Python, Django, MySQL, and Apache. It uses MDSplus for data management, Memcached for data caches, and OpenID for single sign-on security. This paper describes the software architecture, related technologies and deployment experiences of the monitoring portal.

  11. Technical aspects of portal technology application for e-health systems.

    Science.gov (United States)

    Kosińska, Joanna; Słowikowski, Paweł

    2004-01-01

    E-health is an emerging field on the intersection of medical information technologies, public health and business, referring to health services and information delivered or enhanced through the Internet and related technologies. Portal technology, allowing services to be accessible over the Internet is a perfect tool for providing e-health services. The use of portal technologies has had deep influence on the architecture of the whole e-health system, both regarding new subsystems and older ones which we want to integrate with the portal. Portals provide new possibilities for creating novel types of e-health applications as well. In this paper we provide a brief overview of e-health systems and portal technologies, and present many technical aspects of portal technology application for e-health systems such as the architecture of portal-based e-health systems, graphical user interfaces, access to various e-health systems' resources, personalization, security and privacy.

  12. Correlation between severity of portal hypertensive gastropathy and size of oesophageal varices in cirrhotic hepatitis-C patients

    International Nuclear Information System (INIS)

    Saleem, K.; Baig, F.A.; Javed, M.

    2018-01-01

    Portal hypertension can lead to oesophageal varices (EV) and portal hypertensive gastropathy (PHG). The aim of this study is to determine the relationship between severity of Portal hypertensive gastropathy and size of oesophageal varices. Methods: One hundred and ninety-five patients of hepatitis C positive chronic liver disease having oesophageal varices were assessed for severity of portal hypertensive gastropathy. Results: Mild Portal Hypertensive Gastropathy was observed in 16 (8.2 %), moderate in 54 (27.7 %) and severe in 120 (61.6 %) patients. Grade 1 Oesophageal Varices were present in 79 (40.5%) patients, grade 2 in 44(21.9%) patients, grade 3 in 62 (31.8%) and grade 4 in 10 (5.2%) patients. No significant correlation was observed between grades of gastropathy and size of varices. Conclusion: The frequency of portal hypertensive gastropathy was 97.5% in Hepatitis C positive cirrhotic patients having oesophageal varices. Severity of gastropathy is not related to the grade or size of oesophageal varices. (author)

  13. An Approach for harmonizing European Water Portals

    Science.gov (United States)

    Pesquer, Lluís; Stasch, Christoph; Masó, Joan; Jirka, Simon; Domingo, Xavier; Guitart, Francesc; Turner, Thomas; Hinderk Jürrens, Eike

    2017-04-01

    A number of European funded research projects is developing novel solutions for water monitoring, modeling and management. To generate innovations in the water sector, third parties from industry and the public sector need to take up the solutions and bring them into the market. A variety of portals exists to support this move into the market. Examples on the European level are the EIP Water Online Marketplace(1), the WaterInnEU Marketplace(2), the WISE RTD Water knowledge portal(3), the WIDEST- ICT for Water Observatory(4) or the SWITCH-ON Virtual Product Market and Virtual Water-Science Laboratory(5). Further innovation portals and initiatives exist on the national or regional level, for example, the Denmark knows water platform6 or the Dutch water alliance(7). However, the different portals often cover the same projects, the same products and the same services. Since they are technically separated and have their own data models and databases, people need to duplicate information and maintain it at several endpoints. This requires additional efforts and hinders the interoperable exchange between these portals and tools using the underlying data. In this work, we provide an overview on the existing portals and present an approach for harmonizing and integrating common information that is provided across different portals. The approach aims to integrate the common in formation in a common database utilizing existing vocabularies, where possible. An Application Programming Interface allows access the information in a machine-readable way and utilizing the information in other applications beyond description and discovery purposes. (1) http://www.eip-water.eu/my-market-place (2) https://marketplace.waterinneu.org (3) http://www.wise-rtd.info/ (4) http://iwo.widest.eu (5) http://www.switch-on-vwsl.eu/ (6) http://www.rethinkwater.dk/ (7) http://wateralliance.nl/

  14. Comparison between two portal laparoscopy and open surgery for ovariectomy in dogs.

    Science.gov (United States)

    Shariati, Elnaz; Bakhtiari, Jalal; Khalaj, Alireza; Niasari-Naslaji, Amir

    2014-01-01

    Ovariectomy (OVE) is a routine surgical procedure for neutering in small animal practice. Laparoscopy is a new surgical technique which contains advantages such as less trauma, smaller incision and excellent visualization than traditional open surgery. The present study was conducted to examine the feasibility and safety of laparoscopic procedure through two portal comparing with the conventional open surgery for OVE in healthy female bitches (n=16). Dogs were divided in two equal groups. In laparoscopic group, two 5 and 10 mm portals were inserted; First in the umbilicus for introducing the camera and the second, caudal to the umbilicus for inserting the forceps. Laparoscopic procedure involved grasping and tacking the ovary to the abdominal wall, followed by electrocautery, resection and removal of the ovary. In open surgery, routine OVE was conducted through an incision from umbilicus to caudal midline. Mean operative time, total length of scar, blood loss, clinical and blood parameters and all intra and post-operative complications were recorded in both groups. Mean operative time, total length of scar, blood loss and post-operative adhesions were significantly less in laparoscopic group compared with open surgery. In conclusion, laparoscopic OVE is an acceptable procedure due to more advantages in comparison with traditional OVE.

  15. Analysis of Dynamic Characteristics of Portal Frame with Variable Section

    Directory of Open Access Journals (Sweden)

    Hao Jianing

    2016-01-01

    Full Text Available Combined with a portal frame design, by the use of finite element software ANSYS, the finite element model of single specimens of portal rigid frame and the overall portal rigid frame building are established. portal rigid frame’s beam and column is variable cross section. Through the modal analysis, comparative analysis of the frequency and vibration type of the radiolabeling specimens and finite element model of the whole, for the further development of variable cross-section portal rigid frame of earthquake and wind vibration analysis lay the foundation.

  16. Radionuclide assessment of portal hypertension syndrome

    International Nuclear Information System (INIS)

    Aliev, M.A.; Khusain, Sh.K.; Alpeisova, Sh.T.

    2005-01-01

    This paper presents review of radionuclide studies for portal hypertension patients. Presented results showed that portal hypertension signs were revealed for the first group patients. The signs become apparent by splenomegaly and increase of colloid accumulation in it. Accumulation of the chemical in spleen was evidence of ingestion rate increase of reticuloendothelial system owing to its hyperplasia as well as liver phagocytic activity decrease due to pathological paren-chematous process and inter liver blockade. The most typical scintigraphic signs of portal hypertension were determined according chemical accumulation decreased in spleen and marrow sequentially. It is determined radionuclide method contributes to assessment of structural and functional aberrations character in liver and spleen for cirrhosis patients. (author)

  17. [Association of biliary calculosis and portal cavernomatosis].

    Science.gov (United States)

    Crespi, C; De Giorgio, A M

    1992-08-01

    This paper reports the case of a woman, who underwent surgery because of cholelithiasis, with intraoperative finding of prehepatic portal hypertension from portal vein thrombosis ("portal cavernoma") with healthy liver, later confirmed by angiographic studies. This rare pathologic association carries a higher risk of major operative complications; therefore the Authors agree with the general belief that, for these cases, biliary tract surgery should be as simple and safe as possible. In the case of preoperative diagnosis of biliary disease associated with portal cavernoma, should a surgical approach on the biliary tract be required, we agree on the advisability of performing a shunting procedure before any kind of biliary surgery. In case of variceal bleeding endoscopic sclerotherapy will be the first choice; surgical procedures (shunting) should be seen as a second choice in case of rebleeding after sclerotherapy.

  18. Patient activation and use of an electronic patient portal.

    Science.gov (United States)

    Ancker, Jessica S; Osorio, Snezana N; Cheriff, Adam; Cole, Curtis L; Silver, Michael; Kaushal, Rainu

    2015-01-01

    Electronic patient portals give patients access to personal medical data, potentially creating opportunities to improve knowledge, self-efficacy, and engagement in healthcare. The combination of knowledge, self-efficacy, and engagement has been termed activation. Our objective was to assess the relationship between patient activation and outpatient use of a patient portal. Survey. A telephone survey was conducted with 180 patients who had been given access to a portal, 113 of whom used it and 67 of whom did not. The validated patient activation measure (PAM) was administered along with questions about demographics and behaviors. Portal users were no different from nonusers in patient activation. Portal users did have higher education level and more frequent Internet use, and were more likely to have precisely 2 prescription medications than to have more or fewer. Patients who chose to use an electronic patient portal were not more highly activated than nonusers, although they were more educated and more likely to be Internet users.

  19. Radiation therapists' perceptions of the minimum level of experience required to perform portal image analysis

    Energy Technology Data Exchange (ETDEWEB)

    Rybovic, Michala [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, PO Box 170, Lidcombe, NSW 1825 (Australia)], E-mail: mryb6983@mail.usyd.edu.au; Halkett, Georgia K. [Western Australia Centre for Cancer and Palliative Care, Curtin University of Technology, Health Research Campus, GPO Box U1987, Perth, WA 6845 (Australia)], E-mail: g.halkett@curtin.edu.au; Banati, Richard B. [Faculty of Health Sciences, Brain and Mind Research Institute - Ramaciotti Centre for Brain Imaging, University of Sydney, PO Box 170, Lidcombe, NSW 1825 (Australia)], E-mail: r.banati@usyd.edu.au; Cox, Jennifer [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, PO Box 170, Lidcombe, NSW 1825 (Australia)], E-mail: jenny.cox@usyd.edu.au

    2008-11-15

    Background and purpose: Our aim was to explore radiation therapists' views on the level of experience necessary to undertake portal image analysis and clinical decision making. Materials and methods: A questionnaire was developed to determine the availability of portal imaging equipment in Australia and New Zealand. We analysed radiation therapists' responses to a specific question regarding their opinion on the minimum level of experience required for health professionals to analyse portal images. We used grounded theory and a constant comparative method of data analysis to derive the main themes. Results: Forty-six radiation oncology facilities were represented in our survey, with 40 questionnaires being returned (87%). Thirty-seven radiation therapists answered our free-text question. Radiation therapists indicated three main themes which they felt were important in determining the minimum level of experience: 'gaining on-the-job experience', 'receiving training' and 'working as a team'. Conclusions: Radiation therapists indicated that competence in portal image review occurs via various learning mechanisms. Further research is warranted to determine perspectives of other health professionals, such as radiation oncologists, on portal image review becoming part of radiation therapists' extended role. Suitable training programs and steps for implementation should be developed to facilitate this endeavour.

  20. Computer tomographic findings in portal hypertension due to cirrhosis of the liver. Pt. 1

    International Nuclear Information System (INIS)

    Koester, O.; Kunz, R.; Fischer, P.; Lackner, K.; Koischwitz, D.; Bonn Univ.

    1983-01-01

    The CT findings in 80 patients with confirmed portal hypertension due to intrahepatic block were analysed retrospectively. The findings included ascites, hypo-dense areas in the liver, nodular or irregular liver contour, the inability of define intrahepatic portal vessels with narrow window settings, the so-called ''kissing'' sign and evidence of hepato-fugal collaterals and thickning of the wall of the oesophagus. Electronic measurements of various organs (liver, spleen) and vessel diameters (portal vein, superior mesenteric vein) provide parameters which permit classification of patients into the cirrhotic group, as compared with a control group. The statistical significance of this classification was checked by the Kolmogoroff-Smirnoff test. (orig.)

  1. Computer tomographic findings in portal hypertension due to cirrhosis of the liver. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Koester, O; Kunz, R; Fischer, P; Lackner, K; Koischwitz, D

    1983-06-01

    The CT findings in 80 patients with confirmed portal hypertension due to intrahepatic block were analysed retrospectively. The findings included ascites, hypo-dense areas in the liver, nodular or irregular liver contour, the inability of define intrahepatic portal vessels with narrow window settings, the so-called ''kissing'' sign and evidence of hepato-fugal collaterals and thickening of the wall of the oesophagus. Electronic measurements of various organs (liver, spleen) and vessel diameters (portal vein, superior mesenteric vein) provide parameters which permit classification of patients into the cirrhotic group, as compared with a control group. The statistical significance of this classification was checked by the Kolmogoroff-Smirnoff test.

  2. Development of an online clinical trial recruitment portal for the NIHR mental health BRC.

    Science.gov (United States)

    Markham, Sarah

    2016-01-01

    ; many said yes, they would. The manager of the BRC on reviewing the website, agreed that a final version of the website with the NIHR Mental Health BRC logo would be paid for and will form part of a new main website for the BRC in early 2016. ᅟ. Public & patient recruitment to clinical trials is viewed as one of the main barriers to the implementation of clinical trials. This difficulty is often attributed to the working culture of the NHS, rapid turnover of staff and patients and poor-gatekeeping in referring patients to suitable clinical trials. In response to the recruitment difficulties experienced by the Psychosis Studies Clinical Academic Group at the NIHR Mental Health Biomedical Research Centre, Denmark Hill, London, a member of the Office of Psychosis Studies at King's College London and a member (the author) of the King's Clinical Trials Unit, King's College London developed an initiative to create an online clinical trial recruitment portal/information hub for the NIHR Mental Health BRC. The primary purpose of this initiative being to promote patient and public awareness of and interest in participating in clinical trials.

  3. Enviroportal.sk - information portal about the environment

    International Nuclear Information System (INIS)

    Navratil, R.; Kmet, M.

    2005-01-01

    In this presentation author deals with history, conception and exploitation of information portal about environment in the Slovak Republic. This portal - Enviroportal.sk was introduced into service in testing operation in April 2005. Perspectives of Enviroportal.sk are discussed

  4. An Accurate Full-flexion Anterolateral Portal for Needle Placement in the Knee Joint With Dry Osteoarthritis.

    Science.gov (United States)

    Hussein, Mohamed

    2017-07-01

    Accurate delivery of an injection into the intra-articular space of the knee is achieved in only two thirds of knees when using the standard anterolateral portal. The use of a modified full-flexion anterolateral portal provides a highly accurate, less painful, and more effective method for reproducible intra-articular injection without the need for ultrasonographic or fluoroscopic guidance in patients with dry osteoarthritis of the knee. The accuracy of needle placement was assessed in a prospective series of 140 consecutive injections in patients with symptomatic degenerative knee arthritis without clinical knee effusion. Procedural pain was determined using the Numerical Rating Scale. The accuracy rates of needle placement were confirmed with fluoroscopic imaging to document the dispersion pattern of injected contrast material. Using the standard anterolateral portal, 52 of 70 injections were confirmed to have been placed in the intra-articular space on the first attempt (accuracy rate, 74.2%). Using the modified full-flexion anterolateral portal, 68 of 70 injections were placed in the intra-articular space on the first attempt (accuracy rate, 97.1%; P = 0.000). This study revealed that using the modified full-flexion anterolateral portal for injections into the knee joint resulted in more accurate and less painful injections than those performed by the same orthopaedic surgeon using the standard anterolateral portal. In addition, the technique offered therapeutic delivery into the joint without the need for fluoroscopic confirmation. Therapeutic Level II.

  5. SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

    International Nuclear Information System (INIS)

    Qiu, J; Yang, D

    2015-01-01

    Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from

  6. SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, J [Washington University in St Louis, Taian, Shandong (China); Yang, D [Washington University School of Medicine, St Louis, MO (United States)

    2015-06-15

    Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from

  7. Comparison of Technical and Clinical Outcome of Transjugular Portosystemic Shunt Placement Between a Bare Metal Stent and a PTFE-Stentgraft Device

    Energy Technology Data Exchange (ETDEWEB)

    Lauermann, J., E-mail: jostlauermann@gmail.com [Hannover Medical School, Department of Diagnostic and Interventional Radiology (Germany); Potthoff, A. [Hannover Medical School, Department of Gastroenterology, Hepatology and Endocrinology (Germany); Mc Cavert, M. [Beaumont Hospital, Department of Diagnostic and Interventional Radiology (Ireland); Marquardt, S. [Hannover Medical School, Department of Diagnostic and Interventional Radiology (Germany); Vaske, B. [Hannover Medical School, Institute of Biometry (Germany); Rosenthal, H. [Hannover Medical School, Department of Diagnostic and Interventional Radiology (Germany); Hahn, T. von [Hannover Medical School, Department of Gastroenterology, Hepatology and Endocrinology (Germany); Wacker, F.; Meyer, B. C.; Rodt, Thomas, E-mail: rodt.thomas@mh-hannover.de [Hannover Medical School, Department of Diagnostic and Interventional Radiology (Germany)

    2016-04-15

    PurposeTo analyse technical and clinical success of transjugular intrahepatic portosystemic shunt (TIPS) in patients with portal hypertension and compare a stent and a stentgraft with regard to clinical and technical outcome and associated costs.Materials and Methods170 patients (56 ± 12 years, 32.9 % females) treated with TIPS due to portal hypertension were reviewed. 80 patients received a stent (group 1) and 83 a stentgraft (group 2), and seven interventions were unsuccessful. Technical data, periprocedural imaging, follow-up ultrasound and clinical data were analysed with focus on technical success, patency, clinical outcome and group differences. Cost analysis was performed.ResultsPortal hypertension was mainly caused by ethyltoxic liver cirrhosis with ascites as dominant symptom (80 %). Technical success was 93.5 % with mean portosystemic gradient decrease from 16.1 ± 4.8 to 5.1 ± 2.1 mmHg. No significant differences in technical success and portosystemic gradient decrease between the groups were observed. Kaplan–Meier analysis yielded significant differences in primary patency after 14 days, 6 months and 2 years in favour of the stentgraft. Both groups showed good clinical results without significant difference in 1-year survival and hepatic encephalopathy rate. Costs to establish TIPS and to manage 2-year follow-up with constant patency and clinical success were 8876 € (group 1) and 9394 € (group 2).ConclusionTIPS is a safe and effective procedure to manage portal hypertension. Stent and stentgraft enabled good technical and clinical results with a low complication rate. Primary patency rates are clearly in favour of the stentgraft, whereas the stent was more cost effective with similar clinical results in both groups.

  8. Advances in the management of childhood portal hypertension.

    Science.gov (United States)

    McKiernan, Patrick; Abdel-Hady, Mona

    2015-05-01

    Portal hypertension is one of the most serious complications of childhood liver disease, and variceal bleeding is the most feared complication. Most portal hypertension results from cirrhosis but extra hepatic portal vein obstruction is the single commonest cause. Upper gastrointestinal endoscopy endoscopy remains necessary to diagnose gastro-esophageal varices. Families of children with portal hypertension should be provided with written instructions in case of gastrointestinal bleeding. Children with large varices should be considered for primary prophylaxis on a case-by-case basis. The preferred method is variceal band ligation. Children with acute bleeding should be admitted to hospital and treated with antibiotics and pharmacotherapy before urgent therapeutic endoscopy. All children who have bled should then receive secondary prophylaxis. The preferred method is variceal band ligation and as yet there is little evidence to support the use of β-blockers. Children with extrahepatic portal vein obstruction should be assessed for suitability of mesoportal bypass.

  9. Best Practices for Building Web Data Portals

    Science.gov (United States)

    Anderson, R. A.; Drew, L.

    2013-12-01

    With a data archive of more than 1.5 petabytes and a key role as the NASA Distributed Active Archive Center (DAAC) for synthetic aperture radar (SAR) data, the Alaska Satellite Facility (ASF) has an imperative to develop effective Web data portals. As part of continuous enhancement and expansion of its website, ASF recently created two data portals for distribution of SAR data: one for the archiving and distribution of NASA's MEaSUREs Wetlands project and one for newly digitally processed data from NASA's 1978 Seasat satellite. These case studies informed ASF's development of the following set of best practices for developing Web data portals. 1) Maintain well-organized, quality data. This is fundamental. If data are poorly organized or contain errors, credibility is lost and the data will not be used. 2) Match data to likely data uses. 3) Identify audiences in as much detail as possible. ASF DAAC's Seasat and Wetlands portals target three groups of users: a) scientists already familiar with ASF DAAC's SAR archive and our data download tool, Vertex; b) scientists not familiar with SAR or ASF, but who can use the data for their research of oceans, sea ice, volcanoes, land deformation and other Earth sciences; c) audiences wishing to learn more about SAR and its use in Earth sciences. 4) Identify the heaviest data uses and the terms scientists search for online when trying to find data for those uses. 5) Create search engine optimized (SEO) Web content that corresponds to those searches. Because search engines do not yet search raw data, so Web data portals must include content that ties the data to its likely uses. 6) Create Web designs that best serves data users (user centered design), not for how the organization views itself or its data. Usability testing was conducted for the ASF DAAC Wetlands portal to improve the user experience. 7) Use SEO tips and techniques. The ASF DAAC Seasat portal used numerous SEO techniques, including social media, blogging

  10. The Higgs portal above threshold

    Energy Technology Data Exchange (ETDEWEB)

    Craig, Nathaniel [Department of Physics, University of California,Santa Barbara, CA 93106 (United States); Lou, Hou Keong [Department of Physics, Princeton University,Princeton, NJ 08540 (United States); McCullough, Matthew [Theory Division, CERN,1211 Geneva 23 (Switzerland); Thalapillil, Arun [Department of Physics and Astronomy, Rutgers University,Piscataway, NJ 08854 (United States)

    2016-02-18

    The discovery of the Higgs boson opens the door to new physics interacting via the Higgs Portal, including motivated scenarios relating to baryogenesis, dark matter, and electroweak naturalness. We systematically explore the collider signatures of singlet scalars produced via the Higgs Portal at the 14 TeV LHC and a prospective 100 TeV hadron collider. We focus on the challenging regime where the scalars are too heavy to be produced in the decays of an on-shell Higgs boson, and instead are produced primarily via an off-shell Higgs. Assuming these scalars escape the detector, promising channels include missing energy in association with vector boson fusion, monojets, and top pairs. We forecast the sensitivity of searches in these channels at √s=14 & 100 TeV and compare collider reach to the motivated parameter space of singlet-assisted electroweak baryogenesis, Higgs Portal dark matter, and neutral naturalness.

  11. The Higgs portal above threshold

    International Nuclear Information System (INIS)

    Craig, Nathaniel; Lou, Hou Keong; McCullough, Matthew; Thalapillil, Arun

    2016-01-01

    The discovery of the Higgs boson opens the door to new physics interacting via the Higgs Portal, including motivated scenarios relating to baryogenesis, dark matter, and electroweak naturalness. We systematically explore the collider signatures of singlet scalars produced via the Higgs Portal at the 14 TeV LHC and a prospective 100 TeV hadron collider. We focus on the challenging regime where the scalars are too heavy to be produced in the decays of an on-shell Higgs boson, and instead are produced primarily via an off-shell Higgs. Assuming these scalars escape the detector, promising channels include missing energy in association with vector boson fusion, monojets, and top pairs. We forecast the sensitivity of searches in these channels at √s=14 & 100 TeV and compare collider reach to the motivated parameter space of singlet-assisted electroweak baryogenesis, Higgs Portal dark matter, and neutral naturalness.

  12. Large vehicle portal monitor for perimeter safeguards applications

    International Nuclear Information System (INIS)

    Caldwell, J.T.; Atwater, H.F.; Bernard, W.; Bieri, J.M.; Shunk, E.R.

    1979-01-01

    We have developed a class of vehicle portal monitors based on shielded 4π geometry neutron counting. we have derived and experimentally verified an analytical expression relating the detection sensitivity of the neutron tunnel vehicle portal monitor to four design parameters of the system. For a given number of neutron detectors, this design achieves one or more orders of magnitude improvement in nuclear materials detection sensitivity over previous vehicle portal monitors

  13. Effects on growth after hypertension portal induced in young rats Efeitos da hipertensão portal sobre o crescimento de ratos jovens

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Correia Miranda

    2004-03-01

    Full Text Available BACKGROUND: Physical growth retardation in children with hypertension portal was observed regardless of schistosomiasis. It has been suggested that the shunt of portal blood through portosystemic collateral vessels would result in metabolic consequences that would lead to the physical growth deficit observed. AIM: Study the effects of hypertension portal in the growth of young rats. METHODS: The growth of 20 young rats, divided in the groups hypertension portal, n = 10, 103 3.7 g and sham operation n = 10, 102.6 ± 3.4 g was evaluated throughout 5 weeks and the following parameters were under observation: quality of diet offered, diet ingestion, weight increase and urinary creatinine within 24 hours. At the end of the experiment, blood was taken for biochemical tests, prothrombin time and hematocrit and hypertension portal was measured. RESULTS/CONCLUSIONS: Rats with hypertension portal induced at early stages of their lives present growth delay in the first week after surgery recovering their growth rhythm in the next weeks, catching up with the sham animals. Differences related to urinary creatinine excretion, biochemical tests and hematocrit were not observed. Such results are evidence against the hypothesis that the hypertension portal induced in early stages of rats lives would cause delay in their growth.RACIONAL: Atraso no crescimento foi observado em crianças com hipertensão portal independentemente da presença de esquistossomose. Sugeriu-se que o desvio de sangue pelas colaterais portossistêmicas justificaria os achados clínicos encontrados. OBJETIVO: Estudar os efeitos da hipertensão portal no crescimento de ratos jovens. MÉTODOS: O crescimento de 20 ratos divididos nos grupos hipertensão portal n = 10, 103 ± 3,7 g e grupo-controle, n = 10, 102,6 ± 3,4 g foi avaliado durante 5 semanas. Foram considerados a qualidade da dieta oferecida, a ingestão da dieta, o ritmo de crescimento ganho de peso, a excreção de creatinina urin

  14. Abnormal portal vein waveform as an indicator of constrictive pericarditis – a case report

    Directory of Open Access Journals (Sweden)

    Joanna Ścieszka

    2015-06-01

    Full Text Available We report a case of a 17-year-old patient referred to our outpatient Doppler Department due to clinical suspicion of liver cirrhosis. The patient presented with non-specifi c symptoms, such as malaise, pain in the right subcostal region, peripheral oedema. Until then, diagnostic imaging, including echocardiography was inconclusive. We performed the Doppler sonography of the portal system, which revealed normal diameter of the portal vein with abnormal, phasic and markedly pulsatile waveform. Hepatic veins distention with pathological reverse fl ow during systole was reported. Additionally, inferior vena cava was dilated and remained unchanged through the respiratory cycle. Basing on the above image a heart disease, which had not been taken into differential diagnosis before, was suggested. The following echocardiography, together with computed tomography, enabled a diagnosis of constrictive pericarditis. Successful pericardiotomy was performed. Such a complicated diagnostics happened to demonstrate an uncommon example of the use of portal vein waveform in making the proper cardiologic diagnosis.

  15. Therapeutic effects of percutaneous transhepatic variceal embolization combined with partial splenic embolization for portal hypertention

    International Nuclear Information System (INIS)

    Hua Yingxue; Yan Zhiping; Cheng Yongde; Qiao Delin; Zhou Bing; Chen Shiwei; Li Yong

    2007-01-01

    Objective: To evaluate the efficiency of percutaneous transhepatic variceal embolization (PTVE) combined with patial splenic embolization (PES)for portal hypertension. Methods: 30 patients with critical portal hypertension were divided randomly into two groups, 15 patients of A group underwent PSE PTVE combined with PSE and 15 of B group underwent PES only. The changes of collateral circulation of the two groups were compared via color Doppler ultrasonography pre-and postoperatively. Results: The hypersplenism was well controlled in both groups after PTVE and PSE. The varices of A group were embolized completely, the flow rate and velocity of portal blood stream were significantly reduced (P<0.05). In addition, the flow rate and velocity together with inner diameter of the azygous vein decreased (P<0.01), but no change shown on portal vein diameter, only with decrease of blood flow and velocity postoperatively were shown in the two groups (P<0.05). During 13-16 months follow-up, gastroesophageal variceal bleeding appeared in 2 patients and formation of portal thrombi in 1 patients of B group. There was no gastroesophageal variceal bleeding in A group but 2 patients appeared portal hypertensive gastroenteropathy (PHG)under endoscopic confirmations. Conclusion: PTVE combined PSE is very efficient for gastroesophageal variceal bleeding and hypersplenism due to portal hypertension, especially for patients with poor hepatic function, possessing simple, economic, less invasive properties and deserving to be recommended. (authors)

  16. Portal hydatid with secondary cavernomatosis.

    Science.gov (United States)

    Rodríguez Sanz, Mª Belén; Roldán Cuena, Mª Del Mar; Blanco Álvarez, Carlos Alberto; Sánchez Jiménez, Raúl

    2017-03-01

    The hydatid cyst is a parasitic infection included within the category of zoonoses, in which there exists a direct or indirect relation with animals, particularly with dogs. We report a clinical case of a patient who has undergone surgery of hydatid cyst in the right hepatic lobe. Seven years later the patient presents hydatid cyst in portal vein with secondary cavernomatosis, which is a rare complication. There are few cases described in the literature. The symtomatology presented by hydatid cyst is variable and the diagnosis is made by ultrasonography, TC and/or RNM. The treatment of choice is the surgical removal of the cyst, prior to surgery Albendazol must be administered for 1-2 weeks and be maintained for 4 more weeks after surgery.

  17. Fundamental factors influencing portal image quality

    International Nuclear Information System (INIS)

    Jaffray, D.A.

    1995-01-01

    It has been recognized that improved methods of verifying radiation field placement in external beam radiotherapy are required in order to make frequent checks of field placement feasible. As a result, a large number of electronic portal imaging systems have been developed as possible replacements for film. These developments have produced digital systems with faster acquisition and improved display contrast, however, the quality of the images acquired with such systems is still disappointing. This presentation examines many of the fundamental factors which limit the quality of radiographs obtained with a megavoltage radiotherapy beam. The size and shape of the radiation sources (focal and extra-focal) in radiotherapy machines and their influence on the spatial resolution of portal images are examined. Monte Carlo simulations of x-ray interactions within the patient determined that a significant fraction of the x-ray scatter generated in the patient is due to bremsstrahlung and positron annihilation. Depending on the detector, the scatter signal can reduce the differential signal-to-noise by 20%. Furthermore, a Monte Carlo study of the interaction of x-rays within typical fluoroscopic imaging detectors (metal plate/phosphor screen) demonstrates the degrading effect of energy absorption noise on the detective quantum efficiency of fluoroscopic based imaging systems. Finally, the spatial frequency content in the x-ray shadowgram is demonstrated to change with x-ray energy, resulting in images that appear to have reduced spatial resolution at megavoltage energies. The relative magnitude of each of these factors will be presented and recommendations for the next generation of portal imaging systems will be made

  18. Prevalence of histological features of idiopathic noncirrhotic portal hypertension in general population: a retrospective study of incidental liver biopsies.

    Science.gov (United States)

    Zuo, Chunlai; Chumbalkar, Vaibhav; Ells, Peter F; Bonville, Daniel J; Lee, Hwajeong

    2017-09-01

    Idiopathic noncirrhotic portal hypertension (INCPH) is associated with histologic changes secondary to obliterative portal venopathy without cirrhosis. We studied the prevalence of individual histological features of INCPH in liver biopsies obtained incidentally during unrelated elective procedures and in elective liver biopsies with the diagnosis of fatty liver disease. A total of 53 incidental liver biopsies obtained intraoperatively during unrelated elective procedures and an additional 28 elective biopsies with the diagnosis of fatty liver disease without portal hypertension and cirrhosis were studied. Various histologic features of INCPH were evaluated. Shunt vessel (30%), phlebosclerosis (27%), increased number of portal vessels (19%) and incomplete septa (17%) were common in these liver biopsies after confounding factors such as co-existing fatty liver disease or fibrosis were excluded. At least one feature of INCPH was noted in 90% of the biopsies. Eight (10%) biopsies showed 5-6 features of INCPH. In total, 11 (14%) of 81 patients had risk factors associated with INCPH, including hypercoagulability, autoimmune disease, exposure to drugs, and infections. No patient had portal hypertension at the end of the follow-up. The histologic features of INCPH are seen in incidental liver biopsies and fatty liver disease without portal hypertension. Ten percent of the biopsies show 5-6 features of INCPH without portal hypertension. Interpreting histologic features in the right clinical context is important for proper patient care.

  19. Observer variability when evaluating patient movement from electronic portal images of pelvic radiotherapy fields

    International Nuclear Information System (INIS)

    Geraint Lewis, D.; Ryan, Karen R.; Smith, Cyril W.

    2005-01-01

    Background and purpose: A study has been performed to evaluate inter-observer variability when assessing pelvic patient movement using an electronic portal imaging device (EPID). Materials and methods: Four patient image sets were used with 3-6 portal images per set. The observer group consisted of nine radiographers with 3-18 months clinical EPID experience. The observers outlined bony landmarks on a digital simulator image and used matching software to evaluate field placement errors (FPEs) on each portal image relative to the reference simulator image. Data were evaluated statistically, using a two-component analysis of variance technique, to quantify both the inter-observer variability in evaluating FPEs and inter-fraction variability in patient position relative to the residuals of the analysis. Intra-observer variability was also estimated using four of the observers carrying out three sets of repeat readings. Results: Eight sets of variance data were analysed, based on FPEs in two orthogonal directions for each of the four patient image sets studied. Initial analysis showed that both inter-observer variation and inter-fraction-patient position variation were statistically significant (P<0.05) in seven of the eight cases evaluated. The averaged root-mean-square (RMS) deviation of the observers from the group mean was 1.1 mm, with a maximum deviation of 5.0 mm recorded for an individual observer. After additional training and re-testing of two of the observers who recorded the largest deviations from the group mean, a subsequent analysis showed the inter-observer variability for the group to be significant in only three of the eight cases, with averaged RMS deviation reduced to 0.5 mm, with a maximum deviation of 2.7 mm. The intra-observer variability was 0.5 mm, averaged over the four observers tested. Conclusions: We have developed a quantitative approach to evaluate inter-observer variability in terms of its statistical significance compared to inter

  20. Characterization of renal hyperemia in portal hypertensive rats

    International Nuclear Information System (INIS)

    Premen, A.J.; Banchs, V.; Go, V.L.W.; Benoit, J.N.; Granger, D.N.

    1986-01-01

    In anesthetized sham-operated control (C) and portal vein stenosed (PVS) rats, renal blood flow (RBF) was measured with radioactive microspheres on days 2, 4, 6, 8, and 10 following surgery. On day 2, only a small increase in RBF (19%) was produced in PVS versus C rats. However, by day 4, a significant increase in RBF (35%) was observed in PVS versus C animals. By day 6, the renal hyperemia in PVS rats reached a maximal value that was 42% higher than in C rats. Thereafter (on days 8 and 10), the renal hyperemia remained at the maximal value. In a separate group of 10-day PVS rats, glucagon antiserum failed to attenuate the 44% increase in RBF observed in PVS versus C rats. Radioimmunoassay of C and PVS plasma (10-day samples) revealed that vasoactive intestinal polypeptide, substance P, cholecystokinin/gastrin, neurotensin, pancreatic polypeptide, beta-endorphin, and peptide histidine-isoleucine amide are not elevated in arterial plasma of PVS rats. These data indicate that the renal hyperemia induced by chronic portal hypertension is manifested within 4 days after the hypertensive insult. Our studies also suggest that at least 9 blood-borne gastrointestinal peptides are not directly involved in the renal response to portal vein stenosis

  1. Characterization of renal hyperemia in portal hypertensive rats

    Energy Technology Data Exchange (ETDEWEB)

    Premen, A.J.; Banchs, V.; Go, V.L.W.; Benoit, J.N.; Granger, D.N.

    1986-03-01

    In anesthetized sham-operated control (C) and portal vein stenosed (PVS) rats, renal blood flow (RBF) was measured with radioactive microspheres on days 2, 4, 6, 8, and 10 following surgery. On day 2, only a small increase in RBF (19%) was produced in PVS versus C rats. However, by day 4, a significant increase in RBF (35%) was observed in PVS versus C animals. By day 6, the renal hyperemia in PVS rats reached a maximal value that was 42% higher than in C rats. Thereafter (on days 8 and 10), the renal hyperemia remained at the maximal value. In a separate group of 10-day PVS rats, glucagon antiserum failed to attenuate the 44% increase in RBF observed in PVS versus C rats. Radioimmunoassay of C and PVS plasma (10-day samples) revealed that vasoactive intestinal polypeptide, substance P, cholecystokinin/gastrin, neurotensin, pancreatic polypeptide, beta-endorphin, and peptide histidine-isoleucine amide are not elevated in arterial plasma of PVS rats. These data indicate that the renal hyperemia induced by chronic portal hypertension is manifested within 4 days after the hypertensive insult. Our studies also suggest that at least 9 blood-borne gastrointestinal peptides are not directly involved in the renal response to portal vein stenosis.

  2. Idiopathic non-cirrhotic portal hypertension: a review

    NARCIS (Netherlands)

    Schouten, Jeoffrey N. L.; Verheij, Joanne; Seijo, Susana

    2015-01-01

    Idiopathic non-cirrhotic portal hypertension (INCPH) is a rare disease characterized of intrahepatic portal hypertension in the absence of cirrhosis or other causes of liver disease and splanchnic venous thrombosis. The etiology of INCPH can be classified in five categories: 1) immunological

  3. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  4. Neonatal intestinal volvulus and preduodenal portal vein associated with situs ambiguus: report of a case.

    Science.gov (United States)

    Watanabe, Toshihiko; Nakano, Miwako; Yamazawa, Kazuki; Maeyama, Katsuhiro; Endo, Masao

    2011-05-01

    Situs ambiguus is a rare lateralization anomaly that is frequently associated with other malformations, including preduodenal portal vein (PDPV), intestinal malrotation, and cardiovascular anomalies. This is a case report on a newborn that was clinically diagnosed with situs ambiguus and midgut volvulus. During surgery the patient was found to have intestinal malrotation, Meckel's diverticulum, and PDPV that was not a direct cause of duodenal obstruction. The patient was treated with Ladd's procedure and resection of Meckel's diverticulum. It is important to be familiar with the spectrum of situs anomalies to prevent trauma to the portal vein with serious complications during surgery.

  5. Cine phase-contrast MR to assess portal blood flow in a 10-year-old girl with abdominal aortic coarctation: a case report

    International Nuclear Information System (INIS)

    Clark, T.W.I.; Culham, J.A.G.

    1998-01-01

    We report the case of a 10-year-old girl with repaired abdominal aortic coarctation in whom chronic mesenteric ischemia was clinically suspected. Cine phase-contrast magnetic resonance (MR) was used to determine the difference between fasting and postprandial portal blood flow. Fasting flow rates in the portal vein were normal. After a meal, blood flow in the portal vein increased 226 % over the fasting state, showing normal augmentation. To the best of our knowledge, this is the first application of this technique to a pediatric setting. (orig.)

  6. The specialized portals in the knowledge transfer systems: the ionizing radiation portal http://www.ionizantes.ciemat.es/

    International Nuclear Information System (INIS)

    Arboli, M. Marco; Hernanz, Oscar; Couchoud Gregory, Milagros

    2008-01-01

    Full text: This paper shows the new infrastructure to disseminate RP knowledge and information developed by the community involved in radiation uses. The www.ionizantes.ciemat.es portal has been implemented by CIEMAT and CINDOC- CSIC with the support of the national and international organizations related to the radiation applications. The design and structure of the databases was developed by CIEMAT and CINDOC-CSIC using the experience acquired by both organizations in the knowledge transfer. The initiative aims to establish collaboration with the sector involved in the most important applications of the ionizing radiation uses. The goal is to share resources establishing a new system of information between the experts, researchers and public. The portal also brings the dialogue to the entire sector and provides details of the relevant research projects. The main specific objectives of this portal are: a) To inform about the new projects developed; b) To download publications, reports and papers; c) to learn more about ionizing radiation; d) To promote collaborative knowledge transfer. The portal shows particular relevance to representative international and national organizations, the private sector and the local community relevant organizations. Results: The resources include in the database of the portal are: the agenda, documents, research calls, legislation, research projects, most important journals and summaries, patents and other available tools. The information is presented in a categorized and classified structure. This virtual community offers better knowledge transfer. It also optimizes the communication and research dissemination to the society. (author)

  7. Portal manga

    OpenAIRE

    Temprano Hernandez, Joan

    2011-01-01

    El projecte Portal Manga pretén construir una aplicació web que ha de permetre a una empresa anunciar els seus productes a la web, disposar de una botiga virtual en la que es puguin adquirir aquests productes en format digital i finalment un lector web que en permeti la lectura online.

  8. Portal hypertension and liver cirrhosis in rats: effect of the β3-adrenoceptor agonist SR58611A

    Science.gov (United States)

    Vasina, Valentina; Giannone, Ferdinando; Domenicali, Marco; Latorre, Rocco; Berzigotti, Annalisa; Caraceni, Paolo; Zoli, Marco; De Ponti, Fabrizio; Bernardi, Mauro

    2012-01-01

    BACKGROUND AND PURPOSE β3-Adrenoceptors participate in the regulation of vascular tone in physiological and pathological conditions. We aimed to assess the effect of pharmacological modulation of β3-adrenoceptors on portal pressure (PP) and systemic haemodynamics and their expression in the liver and mesenteric vessels of cirrhotic rats. EXPERIMENTAL APPROACH PP, central venous pressure (CVP) and systemic haemodynamics were invasively assessed in control and CCl4-treated cirrhotic rats before and during infusion of the selective β3-adrenoceptor agonist, SR58611A. Tissue samples were also collected from liver, heart, portal vein and mesenteric artery for immunohistochemistry and molecular biology analysis. The effect of SR58611A on isolated portal vein was assessed. KEY RESULTS At baseline, cirrhotic rats showed portal hypertension, reduced CVP and hyperdynamic circulation. SR58611A induced a significant, dose-dependent decrease in PP in cirrhotic rats, but not in controls. Although both groups manifested a dose-dependent reduction in mean arterial pressure, this effect was associated with decreased cardiac index (CI) and unchanged indicized peripheral vascular resistance (PVRI) in cirrhotic rats and increased CI and decreased PVRI in control animals. Pretreatment with the selective β3-adrenoceptor antagonist SR59230 prevented all SR58611A-induced changes in cirrhotic rats. SR58611A concentration-dependently relaxed portal vein in cirrhotic rats to a significantly greater extent than in healthy rats; pretreatment with SR59230A completely prevented SR58611A-induced cirrhotic portal vein relaxation. Finally, β3-adrenoceptors were identified in the liver, heart and portal vein of cirrhotic and control animals; their expression was increased in cirrhotic rats. CONCLUSIONS AND IMPLICATIONS β3-Adrenoceptors are altered in portal hypertension of experimental cirrhosis and may represent a novel therapeutic target. PMID:22708587

  9. Transjugular Intrahepatic Portosystemic Shunt Placement in Patients with Cirrhosis and Concomitant Portal Vein Thrombosis

    International Nuclear Information System (INIS)

    Ha, Thuong G. Van; Hodge, Justin; Funaki, Brian; Lorenz, Jonathan; Rosenblum, Jordan; Straus, Christopher; Leef, Jeff

    2006-01-01

    Purpose. To determine the safety and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) creation in patients with liver cirrhosis complicated by thrombosed portal vein. Methods. This study reviewed 15 cases of TIPS creation in 15 cirrhotic patients with portal vein thrombosis at our institution over an 8-year period. There were 2 women and 13 men with a mean age of 53 years. Indications were refractory ascites, variceal hemorrhage, and refractory pleural effusion. Clinical follow-up was performed in all patients. Results. The technical success rate was 75% (3/4) in patients with chronic portal vein thrombosis associated with cavernomatous transformation and 91% (10/11) in patients with acute thrombosis or partial thrombosis, giving an overall success rate of 87%. Complications included postprocedural encephalopathy and localized hematoma at the access site. In patients with successful shunt placement, the total follow-up time was 223 months. The 30-day mortality rate was 13%. Two patients underwent liver transplantation at 35 days and 7 months, respectively, after TIPS insertion. One patient had an occluded shunt at 4 months with an unsuccessful revision. The remaining patients had functioning shunts at follow-up. Conclusion. TIPS creation in thrombosed portal vein is possible and might be a treatment option in certain patients

  10. Patient and parent views on a Web 2.0 Diabetes Portal--the management tool, the generator, and the gatekeeper: qualitative study.

    Science.gov (United States)

    Nordfeldt, Sam; Hanberger, Lena; Berterö, Carina

    2010-05-28

    The Internet has undergone rapid development, with significant impact on social life and on modes of communication. Modern management of type 1 diabetes requires that patients have access to continuous support and learning opportunities. Although Web 2.0 resources can provide this support, few pediatric clinics offer it as part of routine diabetes care. We aimed to explore patients' and parents' attitudes toward a local Web 2.0 portal tailored to young patients with type 1 diabetes and their parents, with social networking tools such as message boards and blogs, locally produced self-care and treatment information, and interactive pedagogic devices. Opportunities and obstacles to the implementation of Web 2.0 applications in clinical practice were sought. Participants were 16 mothers, 3 fathers, and 5 young patients (ages 11-18 years; median 14 years) who each wrote an essay on their experience using the portal, irrespective of frequency and/or their success in using it. Two main guiding questions were asked. A qualitative content analysis was conducted of the essays as a whole. Three main categories of portal users' attitudes were found; we named them "the management tool," "the generator," and "the gatekeeper." One category was related to the management tool functionality of the portal, and a wide range of concrete examples was found regarding useful facts and updates. Being enabled to search when necessary and find reliable information provided by local clinicians was regarded as a great advantage, facilitating a feeling of security and being in control. Finding answers to difficult-to-ask questions, questions portal users did not know they had before, and questions focusing on sensitive areas such as anxiety and fear, was also an important feature. A second category was related to the generator function in that visiting the portal could generate more information than expected, which could lead to increased use. Active message boards and chat rooms were found to

  11. Portal Vein Embolization with Radiolabeled Polyvinyl Alcohol Particles in a Swine Model: Hepatic Distribution and Implications for Pancreatic Islet Cell Transplantation

    International Nuclear Information System (INIS)

    Owen, Richard J.; Mercer, John R.; Al-Saif, Faisal; Molinari, Michele; Ashforth, Robert A.; Rajotte, Ray V.; Conner-Spady, Barbara; Shapiro, A. M. James

    2009-01-01

    The distribution of radiolabeled polyvinyl alcohol microspheres (PVAMs) when infused into the portal vein of domestic swine was investigated, with the purpose of assessing implications for pancreatic islet cell transplantation. PVAMs measuring 100-300 μm (Contour SE) and labeled with 99m Tc were infused into the main portal vein of 12 swine, with intermittent portal venous pressure measurements. The infusion catheter was introduced antegradely via direct or indirect cannulation of the portal vein. The liver was subsequently divided into anatomical segments. Radioactivity (decay corrected) was measured for 99m Tc microsphere synthesis, dose preparation, gross organ activities, tissue samples, and blood. Particulate labeling, catheter positioning, and infusion were successful in all cases. The number of particles used was (185,000 ± 24,000) with a volume of 1 ml. Mean portal pressure at 5 min was significantly higher than baseline, but without a significant difference at 15 min. Extrahepatic tissue and serum radioactivity was negligible. A significant difference in number of radioactive particles per gram was detected between segments 6/7 and segments 5/8. Intrasegmental activity was analyzed, and for segments 2/3 a significant difference in the percentage dose per gram across samples was demonstrated (P = 0.001). Effective and stable radiolabeling of PVAMs with 99m Tc-sulfur colloid was demonstrated. Portal venous infusion of 100- to 300-μm particles showed entrapment in the sinusoidal hepatic system with transient portal pressure elevation. Preferential embolization into the right lateral and posterior segments occurs, suggesting that flow dynamics/catheter tip position plays a role in particle distribution.

  12. Clinical significance of the fabella

    International Nuclear Information System (INIS)

    Dodevski, A.; Lazarova-Tosovska, D.; Zhivadinovik, J.; Lazareska, M.

    2012-01-01

    Full text: Introduction: There is variable number of sesamoid bones in the human body; one of them is fabella, located in the tendon of the gastrocnemius muscle. Aim of this study was to investigate the frequency of occurrence of fabella in the Macedonian population and to discuss about clinical importance of this bone. Materials and methods: We retrospectively examined radiographs of 53 patients who had knee exams undertaken for a variety of clinical reasons, performed as a part of their medical treatment. Over a time span of six months, 53 patients (38 males and 15 females, age range 19-60 years, mean age of 36.7±12.3 years) were examined. Results: In seven (13.2%) patients of 53 analyzed reports, fabella was found in the lateral tendon of gastrocnemius muscle. We did not find a significant gender or side difference in the appearance of fabella. Conclusion: Although anatomic studies emphasized a lack of significance of the fabella, this bone has been associated with a spectrum of pathology affecting the knee as fabellar syndrome, perineal nerve injury and fracture. We should think of this sesamoid bone while performing diagnostic and surgical procedures

  13. Trans-anastomotic porto-portal varices in patients with gastrointestinal haemorrhage

    International Nuclear Information System (INIS)

    Mitchell, A.W.M.; Jackson, J.E.

    2000-01-01

    AIM: Porto-portal varices are commonly seen in patients with segmental extra-hepatic portal hypertension and develop to provide a collateral circulation around an area of portal venous obstruction. It is not well recognized that such communications may also develop across surgical anastomoses and be the source of gastrointestinal haemorrhage. The possible mode of development of such communications has not been previously discussed. MATERIALS AND METHODS: Over a 3-year period between 1995 and 1998, porto-portal varices were demonstrated across surgical anastomoses in four patients who were referred for the investigation of acute (two), acute-on-chronic (one) and chronic gastrointestinal bleeding (one). Their medical notes and the findings at angiography were reviewed. RESULTS: Three patients had segmental portal hypertension due to extra-hepatic portal vein (one) or superior mesenteric vein (two) stenosis/occlusion. One patient had mild portal hypertension due to hepatic fibrosis secondary to congenital biliary atresia. At angiography all patients were shown to have varices crossing previous surgical anastomoses. These varices were presumed to be the cause of bleeding in three of the four patients; the site of bleeding in the fourth individual was not determined. CONCLUSIONS: Trans-anastomotic porto-portal varices are rare. They develop in the presence of extra-hepatic portal hypertension and presumably arise within peri-anastomotic inflammatory tissue. Such varices may be difficult to manage and their prognosis is poor when bleeding occurs. Mitchell, A.W.M., Jackson, J.E. (2000)

  14. Improving image quality in portal venography with spectral CT imaging

    International Nuclear Information System (INIS)

    Zhao, Li-qin; He, Wen; Li, Jian-ying; Chen, Jiang-hong; Wang, Ke-yang; Tan, Li

    2012-01-01

    Objective: To investigate the effect of energy spectral CT on the image quality of CT portal venography in cirrhosis patients. Materials and methods: 30 portal hypertension patients underwent spectral CT examination using a single-tube, fast dual tube voltage switching technique. 101 sets of monochromatic images were generated from 40 keV to 140 keV. Image noise and contrast-to-noise ratio (CNR) for portal veins from the monochromatic images were measured. An optimal monochromatic image set was selected for obtaining the best CNR for portal veins. The image noise and CNR of the intra-hepatic portal vein and extra-hepatic main stem at the selected monochromatic level were compared with those from the conventional polychromatic images. Image quality was also assessed and compared. Results: The monochromatic images at 51 keV were found to provide the best CNR for both the intra-hepatic and extra-hepatic portal veins. At this energy level, the monochromatic images had about 100% higher CNR than the polychromatic images with a moderate 30% noise increase. The qualitative image quality assessment was also statistically higher with monochromatic images at 51 keV. Conclusion: Monochromatic images at 51 keV for CT portal venography could improve CNR for displaying hepatic portal veins and improve the overall image quality.

  15. Improving image quality in portal venography with spectral CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Li-qin, E-mail: zhaolqzr@sohu.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); He, Wen, E-mail: hewen1724@sina.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Li, Jian-ying, E-mail: jianying.li@med.ge.com [CT Advanced Application and Research, GE Healthcare, 100176 China (China); Chen, Jiang-hong, E-mail: chenjianghong1973@hotmail.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Wang, Ke-yang, E-mail: ke7ke@sina.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Tan, Li, E-mail: Litan@ge.com [CT product, GE Healthcare, 100176 China (China)

    2012-08-15

    Objective: To investigate the effect of energy spectral CT on the image quality of CT portal venography in cirrhosis patients. Materials and methods: 30 portal hypertension patients underwent spectral CT examination using a single-tube, fast dual tube voltage switching technique. 101 sets of monochromatic images were generated from 40 keV to 140 keV. Image noise and contrast-to-noise ratio (CNR) for portal veins from the monochromatic images were measured. An optimal monochromatic image set was selected for obtaining the best CNR for portal veins. The image noise and CNR of the intra-hepatic portal vein and extra-hepatic main stem at the selected monochromatic level were compared with those from the conventional polychromatic images. Image quality was also assessed and compared. Results: The monochromatic images at 51 keV were found to provide the best CNR for both the intra-hepatic and extra-hepatic portal veins. At this energy level, the monochromatic images had about 100% higher CNR than the polychromatic images with a moderate 30% noise increase. The qualitative image quality assessment was also statistically higher with monochromatic images at 51 keV. Conclusion: Monochromatic images at 51 keV for CT portal venography could improve CNR for displaying hepatic portal veins and improve the overall image quality.

  16. Physics Experiments at the UNEDLabs Portal

    Directory of Open Access Journals (Sweden)

    Juan pedro Sánchez

    2012-01-01

    Full Text Available UNEDLabs is a web portal based on a free, modern, open source, and well-known learning management system: Moodle. This portal joins two theme networks of virtual and remote laboratories (one for Control Engineering and another one for Physics, named AutomatL@bs and FisL@bs, respectively together. AutomatL@bs has been operative for five years now. Following AutomatL@bs’ scheme, FisL@bs was created as a network of remote and virtual laboratories for physics university education via the Internet to offer students the possibility of performing hands-on experiences in different fields of physics in two ways: simulation and real remote operation. Now, both FisL@bs and AutomatL@bs join together (while maintaining their independency into an unique new web portal called UNEDLabs. This work focuses on this new web environment and gives a detailed account of a novel way in Physics to let distance learning students gain practical experience autonomously. This paper explains how the new portal works and the software tools used for creating it. In addition, it also describes the physics experiments which are already operative.

  17. A comparison of rule-based and machine learning approaches for classifying patient portal messages.

    Science.gov (United States)

    Cronin, Robert M; Fabbri, Daniel; Denny, Joshua C; Rosenbloom, S Trent; Jackson, Gretchen Purcell

    2017-09-01

    Secure messaging through patient portals is an increasingly popular way that consumers interact with healthcare providers. The increasing burden of secure messaging can affect clinic staffing and workflows. Manual management of portal messages is costly and time consuming. Automated classification of portal messages could potentially expedite message triage and delivery of care. We developed automated patient portal message classifiers with rule-based and machine learning techniques using bag of words and natural language processing (NLP) approaches. To evaluate classifier performance, we used a gold standard of 3253 portal messages manually categorized using a taxonomy of communication types (i.e., main categories of informational, medical, logistical, social, and other communications, and subcategories including prescriptions, appointments, problems, tests, follow-up, contact information, and acknowledgement). We evaluated our classifiers' accuracies in identifying individual communication types within portal messages with area under the receiver-operator curve (AUC). Portal messages often contain more than one type of communication. To predict all communication types within single messages, we used the Jaccard Index. We extracted the variables of importance for the random forest classifiers. The best performing approaches to classification for the major communication types were: logistic regression for medical communications (AUC: 0.899); basic (rule-based) for informational communications (AUC: 0.842); and random forests for social communications and logistical communications (AUCs: 0.875 and 0.925, respectively). The best performing classification approach of classifiers for individual communication subtypes was random forests for Logistical-Contact Information (AUC: 0.963). The Jaccard Indices by approach were: basic classifier, Jaccard Index: 0.674; Naïve Bayes, Jaccard Index: 0.799; random forests, Jaccard Index: 0.859; and logistic regression, Jaccard

  18. The portals 4.0.1 network programming interface.

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Brian W.; Brightwell, Ronald Brian; Pedretti, Kevin; Wheeler, Kyle Bruce; Hemmert, Karl Scott; Riesen, Rolf E.; Underwood, Keith Douglas; Maccabe, Arthur Bernard; Hudson, Trammell B.

    2013-04-01

    This report presents a specification for the Portals 4.0 network programming interface. Portals 4.0 is intended to allow scalable, high-performance network communication between nodes of a parallel computing system. Portals 4.0 is well suited to massively parallel processing and embedded systems. Portals 4.0 represents an adaption of the data movement layer developed for massively parallel processing platforms, such as the 4500-node Intel TeraFLOPS machine. Sandias Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4.0 is targeted to the next generation of machines employing advanced network interface architectures that support enhanced offload capabilities. 3

  19. Diagnostic value of Doppler assessment of the hepatic and portal vessels and ultrasound of the spleen in liver disease.

    Science.gov (United States)

    O'Donohue, John; Ng, Chaan; Catnach, Susan; Farrant, Patricia; Williams, Roger

    2004-02-01

    To investigate the clinical utility and the intra-observer and inter-observer variability of Doppler ultrasound assessment of the hepatic and portal vessels along with measurement of spleen size in the diagnosis of chronic liver disease and cirrhosis. Ultrasound measurements of portal vein diameter (PVD), portal vein velocity (PVV), hepatic arterial resistance index (HARI), hepatic vein profile (HVP), and spleen size were obtained in 49 controls and 45 patients with liver disease (23 with primary biliary cirrhosis, 22 with hepatitis C) by two experienced observers, who each performed three blinded measurements of each variable. Control values were derived from normal hospital workers. Percutaneous liver biopsies in 41 of the patients showed cirrhosis (14 patients), moderate/severe fibrosis (13 patients), and early disease (14 patients). Seventy-one percent of cirrhotic patients had splenomegaly (> 13.6 cm). The spleen size was significantly larger in cirrhotics (16.0 cm) than in non-cirrhotics (13.0 cm, P HVP was abnormal in 76.9% of cirrhotics, 57.7% of non-cirrhotics and 2.1% of controls (P HVP are useful predictors of chronic liver disease and cirrhosis, and both can be measured reliably and reproducibly. However, Doppler measurements of PVV, PVD and HARI are not useful in distinguishing patients with chronic liver disease from normal controls.

  20. Contemporary use of elastography in liver fibrosis and portal hypertension

    DEFF Research Database (Denmark)

    Thiele, Maja; Kjærgaard, Maria; Thielsen, Peter

    2017-01-01

    significant portal hypertension, techniques and limitations. Four types of ultrasound elastography exist, but there is scarce evidence comparing the different techniques. The majority of experience concern transient elastography for diagnosing fibrosis and cirrhosis in patients with chronic viral hepatitis C...