WorldWideScience

Sample records for clinical radiobiology vol

  1. Experimental radiotherapy and clinical radiobiology. Vol. 20. Proceedings; Experimentelle Strahlentherapie und Klinische Strahlenbiologie. Bd. 20. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Michael; Dahm-Daphi, Jochen; Dikomey, Ekkehard; Petersen, Cordula; Rodemannn, Hans-Peter; Zips, Daniel (eds.)

    2011-07-01

    The proceedings include contributions on the following issues: laser driven proton accelerators on the way for radiotherapy, radiobiological evaluation of new radiations; molecular factors of radiation response; biological targeting; EGFR epidermal growth factor receptor/targeting - combined internal and external irradiation, radiobiology of normal tissues; dose-volume histograms for the radiotherapy: curves without radiobiological relevance or important information for the therapy planning; HPV (human papilloma virus) and radiation sensitivity of HNSCC (head and neck squamous cell carcinomas): evidence, radiobiological mechanism, clinical consequences and perspectives; mechanisms of action and intertumoral heterogeneity of response to EGFR inhibition in radiotherapy of solid tumors; evaluation of biomarkers for radiotherapy.

  2. Experimental radiotherapy and clinical radiobiology. Vol. 22. Proceedings; Experimentelle Strahlentherapie und Klinische Strahlenbiologie. Bd. 25. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Michael; Krause, Mechthild [Universitaetsklinikum Technische Univ. Dresden (Germany). Klinik und Poliklinik fuer Strahlentherapie und Radiologie; Cordes, Nils [Universitaetsklinikum Technische Univ. Dresden (Germany). OncoRay - Nationales Zentrum fuer Strahlenforschung in der Radioonkologie; Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany); Petersen, Cordula [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Klinik und Poliklinik fuer Strahlentherapie und Radioonkologie; Rodemann, H. Peter [Universitaetsklinikum Tuebingen (Germany). Sektion fuer Strahlenbiologie; Rothkamm, Kai [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Lab. fuer Strahlentherapie und Experimentelle Radioonkologie; Zips, Daniel (ed.) [Tuebingen Univ. (Germany). Universitaetsklinik fuer Radioonkologie

    2016-05-01

    The proceedings of the 25th symposium on experimental radiotherapy and clinical radiobiology include papers on the following issues: radiotherapy individualization based on imaging; pre-clinic imaging and new experimental methods; methods and models, micromilieu and metabolism, combined therapy; secondary tumors following radiotherapy; radiogenic effects in normal tissue; resistance mechanism of tumors and normal tissue; personalized radio-oncology - which biological data are needed; pre-clinic and personalized radio-oncology; biomarkers - pre-clinic and translational; translational examinations for personalized radio-oncology.

  3. Experimental radiotherapy and clinical radiobiology. Vol. 22. Proceedings; Experimentelle Strahlentherapie und Klinische Strahlenbiologie. Bd. 22. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Michael; Cordes, Nils; Dikomey, Ekkehard; Krause, Mechthild; Petersen, Cordula; Rodemannn, H. Peter; Zips, Daniel (eds.)

    2013-03-01

    The proceedings of the 22th Symposium on experimental radiotherapy and clinical radiotherapy contain lectures and poster on the following issues: Radiation induced immuno-targeting of tumors; targeting in the radiotherapy; biomarkers; targeting; radio-oncological therapy of rectal carcinoma - contribution of radiobiology for therapy optimization; biomarkers for radiation sensibility; resistance mechanisms of tumors; resistance mechanisms of normal tissue; micro ambience, P13L inhibition in radiotherapy: improvement of the local tumor control by molecular mechanisms or the influence of the tumor micro-ambience? DNA repair; radiation effects and technical development.

  4. Experimental radiotherapy and clinical radiobiology. Vol. 18. Proceedings; Experimentelle Strahlentherapie und Klinische Strahlenbiologie. Bd. 18. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Michael; Dahm-Daphi, Jochen; Dikomey, Ekkehard; Petersen, Cordula; Rodemann, H. Peter; Zips, Daniel (eds.)

    2009-07-15

    The proceedings on experimental radiotherapy and clinical radiobiology contain two review articles (prediction of normal tissue reactions after radiotherapy, ?H2AX foci as a marker for DNA double-strand breaks) and 34 contributions to the following topics: Hypoxia and molecular mechanisms of radiation resistance; biological imaging of the tumor micromilieu; DNA repair, genomic instability and carcerogenesis; molecular factors of radiation resistance; actual controversial discussion on possible irradiation caused metastasis risk enhancement; EGFR inhibition and irradiation; biology of experimental radiation/ normal tissue toxicity.

  5. Bringing the heavy: carbon ion therapy in the radiobiological and clinical context.

    Science.gov (United States)

    Schlaff, Cody D; Krauze, Andra; Belard, Arnaud; O'Connell, John J; Camphausen, Kevin A

    2014-03-28

    Radiotherapy for the treatment of cancer is undergoing an evolution, shifting to the use of heavier ion species. For a plethora of malignancies, current radiotherapy using photons or protons yields marginal benefits in local control and survival. One hypothesis is that these malignancies have acquired, or are inherently radioresistant to low LET radiation. In the last decade, carbon ion radiotherapy facilities have slowly been constructed in Europe and Asia, demonstrating favorable results for many of the malignancies that do poorly with conventional radiotherapy. However, from a radiobiological perspective, much of how this modality works in overcoming radioresistance, and extending local control and survival are not yet fully understood. In this review, we will explain from a radiobiological perspective how carbon ion radiotherapy can overcome the classical and recently postulated contributors of radioresistance (α/β ratio, hypoxia, cell proliferation, the tumor microenvironment and metabolism, and cancer stem cells). Furthermore, we will make recommendations on the important factors to consider, such as anatomical location, in the future design and implementation of clinical trials. With the existing data available we believe that the expansion of carbon ion facilities into the United States is warranted.

  6. Experimental radiotherapy and clinical radiobiology. Vol. 16; Experimentelle Strahlentherapie und Klinische Strahlenbiologie. Bd. 16. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, M.; Dahm-Daphi, J.; Dikomey, E.; Petersen, C.; Rodemann, H.P.; Zips, D. (eds.)

    2007-07-01

    The following topics were dealt with: DNA repair as therapeutical target in radiation therapy, biological imaging and tumor microenvironment, molecular factors of radiation therapy, molecular factors and modulation of the radiation reaction of normal tissues, experimental tumor therapy, EGFR inhibition, the endothel cell as primary target of radiation therapy, molecular and cellular foundations of the radiation biology of protons and ions. (HSI)

  7. Experimental radiotherapy and clinical radiobiology. Vol. 19. Proceedings; Experimentelle Strahlentherapie und Klinische Strahlenbiologie. Bd. 19. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Michael; Dahm-Daphi, Jochen; Dikomey, Ekkehard; Petersen, Cordula; Rodemann, H. Peter; Zips, Daniel (eds.)

    2010-12-18

    The proceedings include review contributions on radio-oncology, and new radiation technologies and molecular prediction; and poster sessions on the following topics: hypoxia; molecular mechanisms of radiation resistance; molecular targeting; DNA repair; biological imaging; biology of experimental radiations; normal tissue toxicity; modern radiotherapy; tumor hypoxia and metabolic micro milieu; immune system and radiotherapy.

  8. Clinical radiobiology of glioblastoma multiforme. Estimation of tumor control probability from various radiotherapy fractionation schemes

    Energy Technology Data Exchange (ETDEWEB)

    Pedicini, Piernicola [I.R.C.C.S.-Regional-Cancer-Hospital-C.R.O.B, Unit of Nuclear Medicine, Department of Radiation and Metabolic Therapies, Rionero-in-Vulture (Italy); Department of Radiation and Metabolic Therapies, I.R.C.C.S.-Regional-Cancer-Hospital-C.R.O.B, Unit of Radiotherapy, Rionero-in-Vulture (Italy); Fiorentino, Alba [Sacro Cuore - Don Calabria Hospital, Radiation Oncology Department, Negrar, Verona (Italy); Simeon, Vittorio [I.R.C.C.S.-Regional-Cancer-Hospital-C.R.O.B, Laboratory of Preclinical and Translational Research, Rionero-in-Vulture (Italy); Tini, Paolo; Pirtoli, Luigi [University of Siena and Tuscany Tumor Institute, Unit of Radiation Oncology, Department of Medicine Surgery and Neurological Sciences, Siena (Italy); Chiumento, Costanza [Department of Radiation and Metabolic Therapies, I.R.C.C.S.-Regional-Cancer-Hospital-C.R.O.B, Unit of Radiotherapy, Rionero-in-Vulture (Italy); Salvatore, Marco [I.R.C.C.S. SDN Foundation, Unit of Nuclear Medicine, Napoli (Italy); Storto, Giovanni [I.R.C.C.S.-Regional-Cancer-Hospital-C.R.O.B, Unit of Nuclear Medicine, Department of Radiation and Metabolic Therapies, Rionero-in-Vulture (Italy)

    2014-10-15

    The aim of this study was to estimate a radiobiological set of parameters from the available clinical data on glioblastoma (GB). A number of clinical trial outcomes from patients affected by GB and treated with surgery and adjuvant radiochemotherapy were analyzed to estimate a set of radiobiological parameters for a tumor control probability (TCP) model. The analytical/graphical method employed to fit the clinical data allowed us to estimate the intrinsic tumor radiosensitivity (α), repair capability (b), and repopulation doubling time (T{sub d}) in a first phase, and subsequently the number of clonogens (N) and kick-off time for accelerated proliferation (T{sub k}). The results were used to formulate a hypothesis for a scheduleexpected to significantly improve local control. The 95 % confidence intervals (CI{sub 95} {sub %}) of all parameters are also discussed. The pooled analysis employed to estimate the parameters summarizes the data of 559 patients, while the studies selected to verify the results summarize data of 104 patients. The best estimates and the CI{sub 95} {sub %} are α = 0.12 Gy{sup -1} (0.10-0.14), b = 0.015 Gy{sup -2} (0.013-0.020), α/b = 8 Gy (5.0-10.8), T{sub d} = 15.4 days (13.2-19.5), N = 1 . 10{sup 4} (1.2 . 10{sup 3} - 1 . 10{sup 5}), and T{sub k} = 37 days (29-46). The dose required to offset the repopulation occurring after 1 day (D{sub prolif}) and starting after T{sub k} was estimated as 0.30 Gy/day (0.22-0.39). The analysis confirms a high value for the α/b ratio. Moreover, a high intrinsic radiosensitivity together with a long kick-off time for accelerated repopulation and moderate repopulation kinetics were found. The results indicate a substantial independence of the duration of the overall treatment and an improvement in the treatment effectiveness by increasing the total dose without increasing the dose fraction. (orig.) [German] Schaetzung eines strahlenbiologischen Parametersatzes auf der Grundlage klinischer Daten bei

  9. In vivo radiobiological assessment of the new clinical carbon ion beams at CNAO.

    Science.gov (United States)

    Facoetti, A; Vischioni, B; Ciocca, M; Ferrarini, M; Furusawa, Y; Mairani, A; Matsumoto, Y; Mirandola, A; Molinelli, S; Uzawa, A; Vilches, Freixas G; Orecchia, R

    2015-09-01

    In this article, the in vivo study performed to evaluate the uniformity of biological doses within an hypothetical target volume and calculate the values of relative biological effectiveness (RBE) at different depths in the spread-out Bragg peak (SOBP) of the new CNAO (National Centre for Oncological Hadrontherapy) carbon beams is presented, in the framework of a typical radiobiological beam calibration procedure. The RBE values (relative to (60)Co γ rays) of the CNAO active scanning carbon ion beams were determined using jejunal crypt regeneration in mice as biological system at the entrance, centre and distal end of a 6-cm SOBP. The RBE values calculated from the iso-effective doses to reduce crypt survival per circumference to 10, ranged from 1.52 at the middle of the SOBP to 1.75 at the distal position and are in agreement with those previously reported from other carbon ion facilities. In conclusion, this first set of in vivo experiments shows that the CNAO carbon beam is radiobiologically comparable with the NIRS (National Institute of Radiological Sciences, Chiba, Japan) and GSI (Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany) ones.

  10. Transformation of Physical DVHs to Radiobiologically Equivalent Ones in Hypofractionated Radiotherapy Analyzing Dosimetric and Clinical Parameters: A Practical Approach for Routine Clinical Practice in Radiation Oncology

    Directory of Open Access Journals (Sweden)

    Zoi Thrapsanioti

    2013-01-01

    Full Text Available Purpose. The purpose of this study was to transform DVHs from physical to radiobiological ones as well as to evaluate their reliability by correlations of dosimetric and clinical parameters for 50 patients with prostate cancer and 50 patients with breast cancer, who were submitted to Hypofractionated Radiotherapy. Methods and Materials. To achieve this transformation, we used both the linear-quadratic model (LQ model and the Niemierko model. The outcome of radiobiological DVHs was correlated with acute toxicity score according to EORTC/RTOG criteria. Results. Concerning the prostate radiotherapy, there was a significant correlation between RTOG acute rectal toxicity and ( and ( dosimetric parameters, calculated for  Gy. Moreover, concerning the breast radiotherapy there was a significant correlation between RTOG skin toxicity and dosimetric parameter, calculated for both  Gy ( and  Gy (. The new tool seems reliable and user-friendly. Conclusions. Our proposed model seems user-friendly. Its reliability in terms of agreement with the presented acute radiation induced toxicity was satisfactory. However, more patients are needed to extract safe conclusions.

  11. Radiation-induced cataract-genesis: pathophysiologic, radiobiological and clinical aspects; Catarate radio-induite: aspects physiopathologiques, radiobiologiques et cliniques

    Energy Technology Data Exchange (ETDEWEB)

    Belkacemi, Y.; Touboul, E.; Meric, J.B. [Hopital Tenon, Service d' Oncologie-Radiotherapie, 75 - Paris (France); Rat, P.; Warnet, J.M. [Paris-5 Univ., Lab. de Toxicologie, UFR Pharmacie, Unite de Pharmacotoxicologie Cellulaire, Service Pharmacie, 75 (France)

    2001-08-01

    Cataract-genesis is a widely reported late effect of irradiated crystalline lens. In this review the authors discussed the different aspects of radiation cataract pathogenesis, and the different mechanisms involved in the lens opacification, particularly the epithelium modifications such as epithelial cell death. The authors also reported the influence of radiation exposure on cataract formation following total body irradiation (TBI) and autologous or allogeneic bone marrow transplantation for hematologic malignancies. Moreover, the radiobiological parameters are not studied for the crystalline lens of human. We applied for the first time the linear quadratic (LQ) and biological effective dose (BED) concept to TBI data. The calculated value of {alpha}/{beta} of 1 Gy is in the range of the values reported for the other late responding tissues. The other risk factors for cataract development after TBI such as age, gender, central nervous system boost, long-term steroid therapy and heparin administration are discussed. In terms of cataract or sicca syndrome prevention, numerous compounds have been successfully tested in experimental models or used for the prevention of radiation-induced xerostomia in patients treated for head and neck cancer. However, none of them has been clinically evaluated for ocular radiation late effects prevention. In this report the authors discussed some of the radioprotectors potentially interesting for radiation-induced cataract or sicca syndrome prevention. (author)

  12. Direct evaluation of radiobiological parameters from clinical data in the case of ion beam therapy: an alternative approach to the relative biological effectiveness.

    Science.gov (United States)

    Cometto, A; Russo, G; Bourhaleb, F; Milian, F M; Giordanengo, S; Marchetto, F; Cirio, R; Attili, A

    2014-12-07

    The relative biological effectiveness (RBE) concept is commonly used in treatment planning for ion beam therapy. Whether models based on in vitro/in vivo RBE data can be used to predict human response to treatments is an open issue. In this work an alternative method, based on an effective radiobiological parameterization directly derived from clinical data, is presented. The method has been applied to the analysis of prostate cancer trials with protons and carbon ions.Prostate cancer trials with proton and carbon ion beams reporting 5 year-local control (LC5) and grade 2 (G2) or higher genitourinary toxicity rates (TOX) were selected from literature to test the method. Treatment simulations were performed on a representative subset of patients to produce dose and linear energy transfer distribution, which were used as explicative physical variables for the radiobiological modelling. Two models were taken into consideration: the microdosimetric kinetic model (MKM) and a linear model (LM). The radiobiological parameters of the LM and MKM were obtained by coupling them with the tumor control probability and normal tissue complication probability models to fit the LC5 and TOX data through likelihood maximization. The model ranking was based on the Akaike information criterion.Results showed large confidence intervals due to the limited variety of available treatment schedules. RBE values, such as RBE = 1.1 for protons in the treated volume, were derived as a by-product of the method, showing a consistency with current approaches. Carbon ion RBE values were also derived, showing lower values than those assumed for the original treatment planning in the target region, whereas higher values were found in the bladder. Most importantly, this work shows the possibility to infer the radiobiological parametrization for proton and carbon ion treatment directly from clinical data.

  13. Functional imaging in oncology. Clinical applications. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Luna, Antonio [Case Western Reserve Univ., Cleveland, OH (United States). Dept. of Radiology; MRI Health Time Group, Jaen (Spain); Vilanova, Joan C. [Girona Univ. (Spain). Clinica Girona - Hospital Sta. Caterina; Hygino da Cruz, L. Celso Jr. (ed.) [CDPI and IRM, Rio de Janeiro (Brazil). Dept. of Radiology; Rossi, Santiago E. [Centro de Diagnostico, Buenos Aires (Argentina)

    2014-06-01

    Easy-to-read manual on new functional imaging techniques in oncology. Explains current clinical applications and outlines future avenues. Includes numerous high-quality illustrations to highlight the major teaching points. In the new era of functional and molecular imaging, both currently available imaging biomarkers and biomarkers under development are expected to lead to major changes in the management of oncological patients. This two-volume book is a practical manual on the various imaging techniques capable of delivering functional information on cancer, including diffusion MRI, perfusion CT and MRI, dual-energy CT, spectroscopy, dynamic contrast-enhanced ultrasonography, PET, and hybrid modalities. This second volume considers the applications and benefits of these techniques in a wide range of tumor types, including their role in diagnosis, prediction of treatment outcome, and early evaluation of treatment response. Each chapter addresses a specific malignancy and is written by one or more acclaimed experts. The lucid text is complemented by numerous high-quality illustrations that highlight key features and major teaching points.

  14. Proton Radiobiology

    Directory of Open Access Journals (Sweden)

    Francesco Tommasino

    2015-02-01

    Full Text Available In addition to the physical advantages (Bragg peak, the use of charged particles in cancer therapy can be associated with distinct biological effects compared to X-rays. While heavy ions (densely ionizing radiation are known to have an energy- and charge-dependent increased Relative Biological Effectiveness (RBE, protons should not be very different from sparsely ionizing photons. A slightly increased biological effectiveness is taken into account in proton treatment planning by assuming a fixed RBE of 1.1 for the whole radiation field. However, data emerging from recent studies suggest that, for several end points of clinical relevance, the biological response is differentially modulated by protons compared to photons. In parallel, research in the field of medical physics highlighted how variations in RBE that are currently neglected might actually result in deposition of significant doses in healthy organs. This seems to be relevant in particular for normal tissues in the entrance region and for organs at risk close behind the tumor. All these aspects will be considered and discussed in this review, highlighting how a re-discussion of the role of a variable RBE in proton therapy might be well-timed.

  15. Radiobiology of human cancer radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J.R.

    1978-01-01

    The author has systematically collected and collated the scientific literature correlating the basic and clinical sciences in this field in order to produce a definitive treatise. The book thoroughly reviews the biology and biochemistry relevant to radiobiology and describes the critical locus for the extinction of cell reproductive capacity. Extensive coverage is given to oxygen effect, hyperthermia, high linear energy transfer, cell populations, and similar topics. Separate sections cover time, dose, and fractionation; radiation hematology; cancer chemotherapy; and cancer immunology. The book also contains invaluable discussions of techniques for optimizing radiotherapy alone and in combination with other therapies.

  16. Radiobiological Research in JINR

    CERN Document Server

    Krasavin, E A

    2000-01-01

    The results of long-term radiobiological and radiation-genetical research in DRRR (Division of Radiobiology) are summarized. The different radiation-induced effects in bacteria, yeasts, mammalian and human cells after irradiation by gamma-rays and heavy charged particles are considered. The important role of DNA repair processes in biological effectiveness of different types of radiation were shown. The data on mutagenic action of such kinds of radiation on pro- and eukaryotic cells were analyzed. On the basis of our data the hypersensitivity of human and mammalian chromosomes after low doses of gamma-rays (10-20 sGy) was revealed. The radiobiological effect of ^{211}At - methylene blue complex on human melanoma cells was studied. The extremely high effectiveness of this complex on melanoma cells was shown.

  17. Introduction to radiobiology of targeted radionuclide therapy

    Directory of Open Access Journals (Sweden)

    Jean-Pierre ePOUGET

    2015-03-01

    Full Text Available During the last decades, new radionuclide-based targeted therapies have emerged as efficient tools for cancer treatment. Targeted radionuclide therapies (TRT are based on a multidisciplinary approach that involves the cooperation of specialists in several research fields. Among them, radiobiologists investigate the biological effects of ionizing radiation, specifically the molecular and cellular mechanisms involved in the radiation response. Most of the knowledge about radiation effects concerns external beam radiation therapy (EBRT and radiobiology has then strongly contributed to the development of this therapeutic approach. Similarly, radiobiology and dosimetry are also assumed to be ways for improving TRT, in particular in the therapy of solid tumors which are radioresistant. However, extrapolation of EBRT radiobiology to TRT is not straightforward. Indeed, the specific physical characteristics of TRT (heterogeneous and mixed irradiation, protracted exposure and low absorbed dose rate differ from those of conventional EBRT (homogeneous irradiation, short exposure and high absorbed dose rate, and consequently the response of irradiated tissues might be different. Therefore, specific TRT radiobiology needs to be explored. Determining dose-effect correlation is also a prerequisite for rigorous preclinical radiobiology studies because dosimetry provides the necessary referential to all TRT situations. It is required too for developing patient-tailored TRT in the clinic in order to estimate the best dose for tumor control, while protecting the healthy tissues, thereby improving therapeutic efficacy. Finally, it will allow to determine the relative contribution of targeted effects (assumed to be dose-related and non-targeted effects (assumed to be non-dose-related of ionizing radiation. However, conversely to EBRT where it is routinely used, dosimetry is still challenging in TRT. Therefore, it constitutes with radiobiology, one of the main

  18. With the Radiobiology Group

    CERN Multimedia

    1980-01-01

    The Radiobiology Group carries out experiments to study the effect of radiation on living cells. The photo shows the apparatus for growing broad beans which have been irradiated by 250 GeV protons. The roots are immersed in a tank of running water (CERN Weekly Bulletin 26 January 1981 and Annual Report 1980 p. 160). Karen Panman, Marilena Streit-Bianchi, Roger Paris.

  19. Radiobiology with heavy charged particles: a historical review

    Energy Technology Data Exchange (ETDEWEB)

    Skarsgard, L.D. [Dept. of Medical Biophysics, B.C. Cancer Research Centre and TRIUMF, Vancouver (Canada)

    1997-09-01

    The presentation will attempt to briefly review some of radiobiological data on the effects of heavy charged particles and to discuss the influence of those studies on the clinical application which followed. (orig./MG)

  20. Radiation Protection Research: Radiobiology

    Energy Technology Data Exchange (ETDEWEB)

    Desaintes, C

    2000-07-01

    The main objectives of research in the field of radiobiology and epidemiology performed at the Belgian Nuclear Research Centre SCK-CEN are (1) to study cancer mortality in nuclear workers in Belgium; to document the feasibility of retrospective cohort studies in Belgium; (2) to participate in the IARC study; (3) to elucidate the molecular basis of the effects of ionising radiation in the mammalian embryo during the early phases of its development; (4) to assess the genetic risk of maternal exposure to ionizing radiation; (5) to elucidate the cellular mechanisms leading to brain damage after prenatal irradiation; (6) to advise authorities and to provide the general population with adequate information concerning the health risk arising from radiation exposure. Progress and major achievements in these topical areas in 1999 are reported.

  1. Radiobiology and Epidemiology

    Energy Technology Data Exchange (ETDEWEB)

    Desaintes, C; Holmstock, L

    2001-04-01

    The main objectives of research in the field of radiobiology and epidemiology performed at the Belgian Nuclear Research Centre SCK-CEN are: (1) to study cancer mortality in nuclear workers in Belgium and to co-ordinate the Belgian contribution to the 'International Collaborative Study of Cancer Risk among Radiation Workers in the Nuclear Industry'; (2) to elucidate the molecular basis of individual susceptibility to ionizing radiation in mammalian embryo during the early phases of its development; (3) to assess the genetic risk of maternal exposure to ionizing radiation; (4) to elucidate the cellular mechanisms leading to brain damage after prenatal irradiation; (5) to monitor the early variations of gene expression induced by ionising radiation and cytokines; (6) to evaluate the use of cytokines and natural substances for improving radiotherapy protocols; (6) to advise authorities and to provide the general population with adequate information concerning the health risk arising from radiation exposure. Progress and major achievements in these topical areas in 2000 are reported.

  2. Microirradiation techniques in radiobiological research

    Indian Academy of Sciences (India)

    Guido A Drexler; Miguel J Ruiz-Gómez

    2015-09-01

    The aim of this work is to review the uses of laser microirradiation and ion microbeam techniques within the scope of radiobiological research. Laser microirradiation techniques can be used for many different purposes. In a specific condition, through the use of pulsed lasers, cell lysis can be produced for subsequent separation of different analytes. Microsurgery allows for the identification and isolation of tissue sections, single cells and subcellular components, using different types of lasers. The generation of different types of DNA damage, via this type of microirradiation, allows for the investigation of DNA dynamics. Ion microbeams are important tools in radiobiological research. There are only a limited number of facilities worldwide where radiobiological experiments can be performed. In the beginning, research was mostly focused on the bystander effect. Nowadays, with more sophisticated molecular and cellular biological techniques, ion microirradiation is used to unravel molecular processes in the field of radiobiology. These include DNA repair protein kinetics or chromatin modifications at the site of DNA damage. With the increasing relevance of charged particles in tumour therapy and new concepts on how to generate them, ion microbeam facilities are able to address unresolved questions concerning particle tumour therapy.

  3. Radiotherapy treatment planning linear-quadratic radiobiology

    CERN Document Server

    Chapman, J Donald

    2015-01-01

    Understand Quantitative Radiobiology from a Radiation Biophysics PerspectiveIn the field of radiobiology, the linear-quadratic (LQ) equation has become the standard for defining radiation-induced cell killing. Radiotherapy Treatment Planning: Linear-Quadratic Radiobiology describes tumor cell inactivation from a radiation physics perspective and offers appropriate LQ parameters for modeling tumor and normal tissue responses.Explore the Latest Cell Killing Numbers for Defining Iso-Effective Cancer TreatmentsThe book compil

  4. A Monte Carlo study for the calculation of the average linear energy transfer (LET) distributions for a clinical proton beam line and a radiobiological carbon ion beam line

    Science.gov (United States)

    Romano, F.; Cirrone, G. A. P.; Cuttone, G.; Di Rosa, F.; Mazzaglia, S. E.; Petrovic, I.; Ristic Fira, A.; Varisano, A.

    2014-06-01

    Fluence, depth absorbed dose and linear energy transfer (LET) distributions of proton and carbon ion beams have been investigated using the Monte Carlo code Geant4 (GEometry ANd Tracking). An open source application was developed with the aim to simulate two typical transport beam lines, one used for ocular therapy and cell irradiations with protons and the other for cell irradiations with carbon ions. This tool allows evaluation of the primary and total dose averaged LET and predict their spatial distribution in voxelized or sliced geometries. In order to reproduce the LET distributions in a realistic way, and also the secondary particles’ contributions due to nuclear interactions were considered in the computations. Pristine and spread-out Bragg peaks were taken into account both for proton and carbon ion beams, with the maximum energy of 62 MeV/n. Depth dose distributions were compared with experimental data, showing good agreement. Primary and total LET distributions were analysed in order to study the influence of contributions of secondary particles in regions at different depths. A non-negligible influence of high-LET components was found in the entrance channel for proton beams, determining the total dose averaged LET by the factor 3 higher than the primary one. A completely different situation was obtained for carbon ions. In this case, secondary particles mainly contributed in the tail that is after the peak. The results showed how the weight of light and heavy secondary ions can considerably influence the computation of LET depth distributions. This has an important role in the interpretation of results coming from radiobiological experiments and, therefore, in hadron treatment planning procedures.

  5. [Systemic approach to radiobiological studies].

    Science.gov (United States)

    Bulanova, K Ia; Lobanok, L M

    2004-01-01

    The principles of information theory were applied for analysis of radiobiological effects. The perception of ionizing radiations as a signal enables living organism to discern their benefits or harm, to react to absolute and relatively small deviations, to keep the logic and chronicle of events, to use the former experience for reacting in presence, to forecast consequences. The systemic analysis of organism's response to ionizing radiations allows explaining the peculiarities of effects of different absorbed doses, hormesis, apoptosis, remote consequences and other post-radiation effects.

  6. Novel Radiobiological Gamma Index for Evaluation of 3-Dimensional Predicted Dose Distribution

    Energy Technology Data Exchange (ETDEWEB)

    Sumida, Iori, E-mail: sumida@radonc.med.osaka-u.ac.jp [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Yamaguchi, Hajime; Kizaki, Hisao; Aboshi, Keiko; Tsujii, Mari; Yoshikawa, Nobuhiko; Yamada, Yuji [Department of Radiation Oncology, NTT West Osaka Hospital, Osaka (Japan); Suzuki, Osamu; Seo, Yuji [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Isohashi, Fumiaki [Department of Radiation Oncology, NTT West Osaka Hospital, Osaka (Japan); Yoshioka, Yasuo [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Ogawa, Kazuhiko [Department of Radiation Oncology, NTT West Osaka Hospital, Osaka (Japan)

    2015-07-15

    Purpose: To propose a gamma index-based dose evaluation index that integrates the radiobiological parameters of tumor control (TCP) and normal tissue complication probabilities (NTCP). Methods and Materials: Fifteen prostate and head and neck (H&N) cancer patients received intensity modulated radiation therapy. Before treatment, patient-specific quality assurance was conducted via beam-by-beam analysis, and beam-specific dose error distributions were generated. The predicted 3-dimensional (3D) dose distribution was calculated by back-projection of relative dose error distribution per beam. A 3D gamma analysis of different organs (prostate: clinical [CTV] and planned target volumes [PTV], rectum, bladder, femoral heads; H&N: gross tumor volume [GTV], CTV, spinal cord, brain stem, both parotids) was performed using predicted and planned dose distributions under 2%/2 mm tolerance and physical gamma passing rate was calculated. TCP and NTCP values were calculated for voxels with physical gamma indices (PGI) >1. We propose a new radiobiological gamma index (RGI) to quantify the radiobiological effects of TCP and NTCP and calculate radiobiological gamma passing rates. Results: The mean RGI gamma passing rates for prostate cases were significantly different compared with those of PGI (P<.03–.001). The mean RGI gamma passing rates for H&N cases (except for GTV) were significantly different compared with those of PGI (P<.001). Differences in gamma passing rates between PGI and RGI were due to dose differences between the planned and predicted dose distributions. Radiobiological gamma distribution was visualized to identify areas where the dose was radiobiologically important. Conclusions: RGI was proposed to integrate radiobiological effects into PGI. This index would assist physicians and medical physicists not only in physical evaluations of treatment delivery accuracy, but also in clinical evaluations of predicted dose distribution.

  7. Radiobiological compensation: A case study of uterine cervix cancer with concurrent chemotherapy

    Science.gov (United States)

    Herrera, Higmar; Yañez, Elvia; López, Jesús

    2012-10-01

    The case of a patient diagnosed with uterine cervix cancer is presented as an example of the clinical application of the radiobiological compensation method implemented at Centro Estatal de Cancerología de Durango. Radiotherapy treatment was initially modified to compensate for the chemotherapy component and, as medical complications arose during treatment delivery resulting in an 18 days gap, new compensation followed. All physical and radiobiological assumptions to calculate the Biologically Effective Dose in the external beam and brachytherapy parts of the treatment are presented. Good local control of the tumor was achieved, the theoretical tolerance limits for the organs at risk were not surpassed and the patient manifested no extensive morbidity.

  8. Radiobiological compensation: A case study of uterine cervix cancer with concurrent chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, Higmar; Yanez, Elvia; Lopez, Jesus [Centro Estatal de Cancerologia de Durango, Victoria de Durango, Durango (Mexico); ISSSTE General Hospital Dr. Santiago Ramon y Cajal, Victoria de Durango, Durango (Mexico)

    2012-10-23

    The case of a patient diagnosed with uterine cervix cancer is presented as an example of the clinical application of the radiobiological compensation method implemented at Centro Estatal de Cancerologia de Durango. Radiotherapy treatment was initially modified to compensate for the chemotherapy component and, as medical complications arose during treatment delivery resulting in an 18 days gap, new compensation followed. All physical and radiobiological assumptions to calculate the Biologically Effective Dose in the external beam and brachytherapy parts of the treatment are presented. Good local control of the tumor was achieved, the theoretical tolerance limits for the organs at risk were not surpassed and the patient manifested no extensive morbidity.

  9. Dosimetry for radiobiology experiments at GANIL

    Science.gov (United States)

    Durantel, Florent; Balanzat, Emmanuel; Cassimi, Amine; Chevalier, François; Ngono-Ravache, Yvette; Madi, Toiammou; Poully, Jean-Christophe; Ramillon, Jean-Marc; Rothard, Hermann; Ropars, Frédéric; Schwob, Lucas; Testard, Isabelle; Saintigny, Yannick

    2016-04-01

    Mainly encouraged by the increasing application of ion beams for cancer treatment (hadron-therapy) including carbon beams, the use of heavy ion facilities for radiobiology is expanding rapidly today. As an alternative to dedicated centers for treatment and medical research, accelerators like GANIL offer the possibility to undertake such experiments. Since 20 years, CIMAP, reinforced 15 years ago by the biological host laboratory LARIA, has been receiving researchers in radiobiology and assisted them in performing experiments in different fields such as hadron-therapy, space radioprotection and fundamental biological and physico-chemical mechanisms. We present here a short description of the beam line and the on-line equipments that allow the automatic irradiation of up to 24 biological samples at once. We also developed an original on-line beam monitoring procedure for low ion flux (low dose rates) based on the measurement of the K-shell X-rays emitted from a thin iron foil. This detector is calibrated on an absolute scale before each experiment by counting etched tracks on an irradiated CR39 polymer plate. We present the performances and limits of this method and finally give typical fluence (dose) uncertainties for a standard irradiation in radiobiology.

  10. Dosimetry for radiobiology experiments at GANIL

    Energy Technology Data Exchange (ETDEWEB)

    Durantel, Florent, E-mail: durantel@ganil.fr [CIMAP-GANIL, Caen (France); Balanzat, Emmanuel; Cassimi, Amine [CIMAP-GANIL, Caen (France); Chevalier, François [CEA/DSV/LARIA, Caen (France); Ngono-Ravache, Yvette; Madi, Toiammou; Poully, Jean-Christophe; Ramillon, Jean-Marc; Rothard, Hermann; Ropars, Frédéric; Schwob, Lucas [CIMAP-GANIL, Caen (France); Testard, Isabelle [CEA/DSV/CBM/iRTSV, Grenoble (France); Saintigny, Yannick [CEA/DSV/LARIA, Caen (France)

    2016-04-21

    Mainly encouraged by the increasing application of ion beams for cancer treatment (hadron-therapy) including carbon beams, the use of heavy ion facilities for radiobiology is expanding rapidly today. As an alternative to dedicated centers for treatment and medical research, accelerators like GANIL offer the possibility to undertake such experiments. Since 20 years, CIMAP, reinforced 15 years ago by the biological host laboratory LARIA, has been receiving researchers in radiobiology and assisted them in performing experiments in different fields such as hadron-therapy, space radioprotection and fundamental biological and physico-chemical mechanisms. We present here a short description of the beam line and the on-line equipments that allow the automatic irradiation of up to 24 biological samples at once. We also developed an original on-line beam monitoring procedure for low ion flux (low dose rates) based on the measurement of the K-shell X-rays emitted from a thin iron foil. This detector is calibrated on an absolute scale before each experiment by counting etched tracks on an irradiated CR39 polymer plate. We present the performances and limits of this method and finally give typical fluence (dose) uncertainties for a standard irradiation in radiobiology.

  11. Physics and radiobiology of nuclear medicine

    CERN Document Server

    Saha, Gopal B

    2010-01-01

    From a distinguished author comes this new edition for technologists, practitioners, residents, and students in radiology and nuclear medicine. Encompassing major topics in nuclear medicine from the basic physics of radioactive decay to instrumentation and radiobiology, it is an ideal review for Board and Registry examinations. The material is well organized and written with clarity. The book is supplemented with tables and illustrations throughout. It provides a quick reference book that is concise but comprehensive, and offers a complete discussion of topics for the nuclear medicine and radi

  12. Radiobiological studies using gamma and x rays.

    Energy Technology Data Exchange (ETDEWEB)

    Potter, Charles Augustus; Longley, Susan W.; Scott, Bobby R.; Lin, Yong; Wilder, Julie; Hutt, Julie A.; Padilla, Mabel T.; Gott, Katherine M.

    2013-02-01

    There are approximately 500 self-shielded research irradiators used in various facilities throughout the U.S. These facilities use radioactive sources containing either 137Cs or 60Co for a variety of biological investigations. A report from the National Academy of Sciences[1] described the issues with security of particular radiation sources and the desire for their replacement. The participants in this effort prepared two peer-reviewed publications to document the results of radiobiological studies performed using photons from 320-kV x rays and 137Cs on cell cultures and mice. The effectiveness of X rays was shown to vary with cell type.

  13. Comparison of treatment plans: a retrospective study by the method of radiobiological evaluation

    Science.gov (United States)

    Puzhakkal, Niyas; Kallikuzhiyil Kochunny, Abdullah; Manthala Padannayil, Noufal; Singh, Navin; Elavan Chalil, Jumanath; Kulangarakath Umer, Jamshad

    2016-09-01

    There are many situations in radiotherapy where multiple treatment plans need to be compared for selection of an optimal plan. In this study we performed the radiobiological method of plan evaluation to verify the treatment plan comparison procedure of our clinical practice. We estimated and correlated various radiobiological dose indices with physical dose metrics for a total of 30 patients representing typical cases of head and neck, prostate and brain tumors. Three sets of plans along with a clinically approved plan (final plan) treated by either Intensity Modulated Radiation Therapy (IMRT) or Rapid Arc (RA) techniques were considered. The study yielded improved target coverage for final plans, however, no appreciable differences in doses and the complication probabilities of organs at risk were noticed. Even though all four plans showed adequate dose distributions, from dosimetric point of view, the final plan had more acceptable dose distribution. The estimated biological outcome and dose volume histogram data showed least differences between plans for IMRT when compared to RA. Our retrospective study based on 120 plans, validated the radiobiological method of plan evaluation. The tumor cure or normal tissue complication probabilities were found to be correlated with the corresponding physical dose indices.

  14. Enregistreur de vol

    OpenAIRE

    Osen, Alexander; Bianchi, Christophe

    2012-01-01

    Ce travail consiste à développer un prototype d'enregistreur de vol spécifique au moto-planeur électrique, il doit donc pouvoir enregistrer la position du planeur et détecter si le système de propulsion est en marche

  15. BNL ACCELERATOR-BASED RADIOBIOLOGY FACILITIES

    Energy Technology Data Exchange (ETDEWEB)

    LOWENSTEIN,D.I.

    2000-05-28

    For the past several years, the Alternating Gradient Synchrotron (AGS) at Brookhaven National Laboratory (USA) has provided ions of iron, silicon and gold, at energies from 600 MeV/nucleon to 10 GeV/nucleon, for the US National Aeronautics and Space Administration (NASA) radiobiology research program. NASA has recently funded the construction of a new dedicated ion facility, the Booster Applications Facility (BAF). The Booster synchrotron will supply ion beams ranging from protons to gold, in an energy range from 40--3,000 MeV/nucleon with maximum beam intensities of 10{sup 10} to 10{sup 11} ions per pulse. The BAF Project is described and the future AGS and BAF operation plans are presented.

  16. Physics and radiobiology of nuclear medicine

    CERN Document Server

    Saha, Gopal B

    2013-01-01

    The Fourth Edition of Dr. Gopal B. Saha’s Physics and Radiobiology of Nuclear Medicine was prompted by the need to provide up-to-date information to keep pace with the perpetual growth and improvement in the instrumentation and techniques employed in nuclear medicine since the last edition published in 2006. Like previous editions, the book is intended for radiology and nuclear medicine residents to prepare for the American Board of Nuclear Medicine, American Board of Radiology, and American Board of Science in Nuclear Medicine examinations, all of which require a strong physics background. Additionally, the book will serve as a textbook on nuclear medicine physics for nuclear medicine technologists taking the Nuclear Medicine Technology Certification Board examination.

  17. Biophysical and biomathematical adventures in radiobiology

    Energy Technology Data Exchange (ETDEWEB)

    Scott, B.R.

    1991-01-01

    Highlights of my biophysical and biomathematical adventures in radiobiology is presented. Early adventures involved developing state-vector models'' for specific harmful effects (cell killing, life shortening) of exposure to radiation. More recent adventures led to developing hazard-function models'' for predicting biological effects (e.g., cell killing, mutations, tumor induction) of combined exposure to different toxicants. Hazard-function models were also developed for predicting harm to man from exposure to large radiation doses. Major conclusions derived from the modeling adventures are as follows: (1) synergistic effects of different genotoxic agents should not occur at low doses; (2) for exposure of the lung or bone marrow to large doses of photon radiation, low rates of exposure should be better tolerated than high rates; and (3) for some types of radiation (e.g., alpha particles and fission neutrons), moderate doses delivered at a low rate may be more harmful than the same dose given at a high rate. 53 refs., 7 figs.

  18. Radiobiological Determination of Dose Escalation and Normal Tissue Toxicity in Definitive Chemoradiation Therapy for Esophageal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Samantha, E-mail: Samantha.warren@oncology.ox.ac.uk [Department of Oncology, Gray Institute of Radiation Oncology and Biology, University of Oxford, Oxford (United Kingdom); Partridge, Mike [Department of Oncology, Gray Institute of Radiation Oncology and Biology, University of Oxford, Oxford (United Kingdom); Carrington, Rhys [Velindre Cancer Centre, Velindre Hospital, Cardiff (United Kingdom); Hurt, Chris [Wales Cancer Trials Unit, School of Medicine, Heath Park, Cardiff (United Kingdom); Crosby, Thomas [Velindre Cancer Centre, Velindre Hospital, Cardiff (United Kingdom); Hawkins, Maria A. [Department of Oncology, Gray Institute of Radiation Oncology and Biology, University of Oxford, Oxford (United Kingdom)

    2014-10-01

    Purpose: This study investigated the trade-off in tumor coverage and organ-at-risk sparing when applying dose escalation for concurrent chemoradiation therapy (CRT) of mid-esophageal cancer, using radiobiological modeling to estimate local control and normal tissue toxicity. Methods and Materials: Twenty-one patients with mid-esophageal cancer were selected from the SCOPE1 database (International Standard Randomised Controlled Trials number 47718479), with a mean planning target volume (PTV) of 327 cm{sup 3}. A boost volume, PTV2 (GTV + 0.5 cm margin), was created. Radiobiological modeling of tumor control probability (TCP) estimated the dose required for a clinically significant (+20%) increase in local control as 62.5 Gy/25 fractions. A RapidArc (RA) plan with a simultaneously integrated boost (SIB) to PTV2 (RA{sub 62.5}) was compared to a standard dose plan of 50 Gy/25 fractions (RA{sub 50}). Dose-volume metrics and estimates of normal tissue complication probability (NTCP) for heart and lungs were compared. Results: Clinically acceptable dose escalation was feasible for 16 of 21 patients, with significant gains (>18%) in tumor control from 38.2% (RA{sub 50}) to 56.3% (RA{sub 62.5}), and only a small increase in predicted toxicity: median heart NTCP 4.4% (RA{sub 50}) versus 5.6% (RA{sub 62.5}) P<.001 and median lung NTCP 6.5% (RA{sub 50}) versus 7.5% (RA{sub 62.5}) P<.001. Conclusions: Dose escalation to the GTV to improve local control is possible when overlap between PTV and organ-at-risk (<8% heart volume and <2.5% lung volume overlap for this study) generates only negligible increase in lung or heart toxicity. These predictions from radiobiological modeling should be tested in future clinical trials.

  19. National Radiobiology Archives Distributed Access user's manual

    Energy Technology Data Exchange (ETDEWEB)

    Watson, C.; Smith, S. (Pacific Northwest Lab., Richland, WA (United States)); Prather, J. (Linfield Coll., McMinnville, OR (United States))

    1991-11-01

    This User's Manual describes installation and use of the National Radiobiology Archives (NRA) Distributed Access package. The package consists of a distributed subset of information representative of the NRA databases and database access software which provide an introduction to the scope and style of the NRA Information Systems.

  20. The photon dose calculation algorithm used in breast radiotherapy has significant impact on the parameters of radiobiological models.

    Science.gov (United States)

    Petillion, Saskia; Swinnen, Ans; Defraene, Gilles; Verhoeven, Karolien; Weltens, Caroline; Van den Heuvel, Frank

    2014-07-08

    The comparison of the pencil beam dose calculation algorithm with modified Batho heterogeneity correction (PBC-MB) and the analytical anisotropic algorithm (AAA) and the mutual comparison of advanced dose calculation algorithms used in breast radiotherapy have focused on the differences between the physical dose distributions. Studies on the radiobiological impact of the algorithm (both on the tumor control and the moderate breast fibrosis prediction) are lacking. We, therefore, investigated the radiobiological impact of the dose calculation algorithm in whole breast radiotherapy. The clinical dose distributions of 30 breast cancer patients, calculated with PBC-MB, were recalculated with fixed monitor units using more advanced algorithms: AAA and Acuros XB. For the latter, both dose reporting modes were used (i.e., dose-to-medium and dose-to-water). Next, the tumor control probability (TCP) and the normal tissue complication probability (NTCP) of each dose distribution were calculated with the Poisson model and with the relative seriality model, respectively. The endpoint for the NTCP calculation was moderate breast fibrosis five years post treatment. The differences were checked for significance with the paired t-test. The more advanced algorithms predicted a significantly lower TCP and NTCP of moderate breast fibrosis then found during the corresponding clinical follow-up study based on PBC calculations. The differences varied between 1% and 2.1% for the TCP and between 2.9% and 5.5% for the NTCP of moderate breast fibrosis. The significant differences were eliminated by determination of algorithm-specific model parameters using least square fitting. Application of the new parameters on a second group of 30 breast cancer patients proved their appropriateness. In this study, we assessed the impact of the dose calculation algorithms used in whole breast radiotherapy on the parameters of the radiobiological models. The radiobiological impact was eliminated by

  1. Design study of the ESS-Bilbao 50 MeV proton beam line for radiobiological studies

    Science.gov (United States)

    Huerta-Parajon, M.; Martinez-Ballarin, R.; Abad, E.

    2015-02-01

    The ESS-Bilbao proton accelerator facility has been designed fulfilling the European Spallation Source (ESS) specifications to serve as the Spanish contribution to the ESS construction. Furthermore, several applications of the ESS-Bilbao proton beam are being considered in order to contribute to the knowledge in the field of radiobiology, materials and aerospace components. Understanding of the interaction of radiation with biological systems is of vital importance as it affects important applications such as cancer treatment with ion beam therapy among others. ESS-Bilbao plans to house a facility exclusively dedicated to radiobiological experiments with protons up to 50 MeV. Beam line design, optimisation and initial calculations of flux densities and absorbed doses were undertaken using the Monte Carlo simulation package FLUKA. A proton beam with a flux density of about 106 protons/cm2 s reaches the water sample with a flat lateral distribution of the dose. The absorbed dose at the pristine Bragg peak calculated with FLUKA is 2.4 ± 0.1 Gy in 1 min of irradiation time. This value agrees with the clinically meaningful dose rates, i.e. around 2 Gy/min, used in hadrontherapy. Optimisation and validation studies in the ESS-Bilbao line for radiobiological experiments are detailed in this article.

  2. Design study of the ESS-Bilbao 50 MeV proton beam line for radiobiological studies

    Energy Technology Data Exchange (ETDEWEB)

    Huerta-Parajon, M., E-mail: mhuerta@essbilbao.org; Martinez-Ballarin, R., E-mail: rmartinez@essbilbao.org; Abad, E., E-mail: eabad@essbilbao.org

    2015-02-01

    The ESS-Bilbao proton accelerator facility has been designed fulfilling the European Spallation Source (ESS) specifications to serve as the Spanish contribution to the ESS construction. Furthermore, several applications of the ESS-Bilbao proton beam are being considered in order to contribute to the knowledge in the field of radiobiology, materials and aerospace components. Understanding of the interaction of radiation with biological systems is of vital importance as it affects important applications such as cancer treatment with ion beam therapy among others. ESS-Bilbao plans to house a facility exclusively dedicated to radiobiological experiments with protons up to 50 MeV. Beam line design, optimisation and initial calculations of flux densities and absorbed doses were undertaken using the Monte Carlo simulation package FLUKA. A proton beam with a flux density of about 10{sup 6} protons/cm{sup 2} s reaches the water sample with a flat lateral distribution of the dose. The absorbed dose at the pristine Bragg peak calculated with FLUKA is 2.4 ± 0.1 Gy in 1 min of irradiation time. This value agrees with the clinically meaningful dose rates, i.e. around 2 Gy/min, used in hadrontherapy. Optimisation and validation studies in the ESS-Bilbao line for radiobiological experiments are detailed in this article.

  3. An Expanded Multi-scale Monte Carlo Simulation Method for Personalized Radiobiological Effect Estimation in Radiotherapy: a feasibility study

    Science.gov (United States)

    Zhang, Ying; Feng, Yuanming; Wang, Wei; Yang, Chengwen; Wang, Ping

    2017-03-01

    A novel and versatile “bottom-up” approach is developed to estimate the radiobiological effect of clinic radiotherapy. The model consists of multi-scale Monte Carlo simulations from organ to cell levels. At cellular level, accumulated damages are computed using a spectrum-based accumulation algorithm and predefined cellular damage database. The damage repair mechanism is modeled by an expanded reaction-rate two-lesion kinetic model, which were calibrated through replicating a radiobiological experiment. Multi-scale modeling is then performed on a lung cancer patient under conventional fractionated irradiation. The cell killing effects of two representative voxels (isocenter and peripheral voxel of the tumor) are computed and compared. At microscopic level, the nucleus dose and damage yields vary among all nucleuses within the voxels. Slightly larger percentage of cDSB yield is observed for the peripheral voxel (55.0%) compared to the isocenter one (52.5%). For isocenter voxel, survival fraction increase monotonically at reduced oxygen environment. Under an extreme anoxic condition (0.001%), survival fraction is calculated to be 80% and the hypoxia reduction factor reaches a maximum value of 2.24. In conclusion, with biological-related variations, the proposed multi-scale approach is more versatile than the existing approaches for evaluating personalized radiobiological effects in radiotherapy.

  4. An Expanded Multi-scale Monte Carlo Simulation Method for Personalized Radiobiological Effect Estimation in Radiotherapy: a feasibility study

    Science.gov (United States)

    Zhang, Ying; Feng, Yuanming; Wang, Wei; Yang, Chengwen; Wang, Ping

    2017-01-01

    A novel and versatile “bottom-up” approach is developed to estimate the radiobiological effect of clinic radiotherapy. The model consists of multi-scale Monte Carlo simulations from organ to cell levels. At cellular level, accumulated damages are computed using a spectrum-based accumulation algorithm and predefined cellular damage database. The damage repair mechanism is modeled by an expanded reaction-rate two-lesion kinetic model, which were calibrated through replicating a radiobiological experiment. Multi-scale modeling is then performed on a lung cancer patient under conventional fractionated irradiation. The cell killing effects of two representative voxels (isocenter and peripheral voxel of the tumor) are computed and compared. At microscopic level, the nucleus dose and damage yields vary among all nucleuses within the voxels. Slightly larger percentage of cDSB yield is observed for the peripheral voxel (55.0%) compared to the isocenter one (52.5%). For isocenter voxel, survival fraction increase monotonically at reduced oxygen environment. Under an extreme anoxic condition (0.001%), survival fraction is calculated to be 80% and the hypoxia reduction factor reaches a maximum value of 2.24. In conclusion, with biological-related variations, the proposed multi-scale approach is more versatile than the existing approaches for evaluating personalized radiobiological effects in radiotherapy. PMID:28322329

  5. MO-D-BRD-03: Radiobiology and Commissioning of Electronic Brachytherapy for IORT

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, J. [Oregon Health & Science Univ (United States)

    2015-06-15

    Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic

  6. New challenges in high-energy particle radiobiology.

    Science.gov (United States)

    Durante, M

    2014-03-01

    Densely ionizing radiation has always been a main topic in radiobiology. In fact, α-particles and neutrons are sources of radiation exposure for the general population and workers in nuclear power plants. More recently, high-energy protons and heavy ions attracted a large interest for two applications: hadrontherapy in oncology and space radiation protection in manned space missions. For many years, studies concentrated on measurements of the relative biological effectiveness (RBE) of the energetic particles for different end points, especially cell killing (for radiotherapy) and carcinogenesis (for late effects). Although more recently, it has been shown that densely ionizing radiation elicits signalling pathways quite distinct from those involved in the cell and tissue response to photons. The response of the microenvironment to charged particles is therefore under scrutiny, and both the damage in the target and non-target tissues are relevant. The role of individual susceptibility in therapy and risk is obviously a major topic in radiation research in general, and for ion radiobiology as well. Particle radiobiology is therefore now entering into a new phase, where beyond RBE, the tissue response is considered. These results may open new applications for both cancer therapy and protection in deep space.

  7. (RadioBiological Optimization of External-Beam Radiotherapy

    Directory of Open Access Journals (Sweden)

    Alan E. Nahum

    2012-01-01

    Full Text Available “Biological optimization” (BIOP means planning treatments using (radiobiological criteria and models, that is, tumour control probability and normal-tissue complication probability. Four different levels of BIOP are identified: Level I is “isotoxic” individualization of prescription dose at fixed fraction number. is varied to keep the NTCP of the organ at risk constant. Significant improvements in local control are expected for non-small-cell lung tumours. Level II involves the determination of an individualized isotoxic combination of and fractionation scheme. This approach is appropriate for “parallel” OARs (lung, parotids. Examples are given using our BioSuite software. Hypofractionated SABR for early-stage NSCLC is effectively Level-II BIOP. Level-III BIOP uses radiobiological functions as part of the inverse planning of IMRT, for example, maximizing TCP whilst not exceeding a given NTCP. This results in non-uniform target doses. The NTCP model parameters (reflecting tissue “architecture” drive the optimizer to emphasize different regions of the DVH, for example, penalising high doses for quasi-serial OARs such as rectum. Level-IV BIOP adds functional imaging information, for example, hypoxia or clonogen location, to Level III; examples are given of our prostate “dose painting” protocol, BioProp. The limitations of and uncertainties inherent in the radiobiological models are emphasized.

  8. Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures

    Energy Technology Data Exchange (ETDEWEB)

    Mavroidis, Panayiotis [Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University (Sweden); Ferreira, Brigida Costa [Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University (Sweden); Shi, Chengyu [Department of Radiation Oncology, University of Texas Health Science Center, San Antonio, TX (United States); Lind, Bengt K [Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University (Sweden); Papanikolaou, Nikos [Department of Radiation Oncology, University of Texas Health Science Center, San Antonio, TX (United States)

    2007-07-07

    The rapid implementation of advanced treatment planning and delivery technologies for radiation therapy has brought new challenges in evaluating the most effective treatment modality. Intensity-modulated radiotherapy (IMRT) using multi-leaf collimators (MLC) and helical tomotherapy (HT) are becoming popular modes of treatment delivery and their application and effectiveness continues to be investigated. Presently, there are several treatment planning systems (TPS) that can generate and optimize IMRT plans based on user-defined objective functions for the internal target volume (ITV) and organs at risk (OAR). However, the radiobiological parameters of the different tumours and normal tissues are typically not taken into account during dose prescription and optimization of a treatment plan or during plan evaluation. The suitability of a treatment plan is typically decided based on dosimetric criteria such as dose-volume histograms (DVH), maximum, minimum, mean and standard deviation of the dose distribution. For a more comprehensive treatment plan evaluation, the biologically effective uniform dose D-bar is applied together with the complication-free tumour control probability (P{sub +}). Its utilization is demonstrated using three clinical cases that were planned with two different forms of IMRT. In this study, three different cancer types at different anatomical sites were investigated: head and neck, lung and prostate cancers. For each cancer type, a linac MLC-based step-and-shoot IMRT plan and a HT plan were developed. The MLC-based IMRT treatment plans were developed on the Philips treatment-planning platform, using the Pinnacle 7.6 software release. For the tomotherapy HiArt plans, the dedicated tomotherapy treatment planning station was used, running version 2.1.2. By using D-bar as the common prescription point of the treatment plans and plotting the tissue response probabilities versus D-bar for a range of prescription doses, a number of plan trials can be

  9. Realization of radiobiological in vitro cell experiments at conventional X-ray tubes and unconventional radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Beyreuther, Elke

    2010-09-10

    More than hundred years after the discovery of X-rays different kinds of ionizing radiation are ubiquitous in medicine, applied to clinical diagnostics and cancer treatment as well. Irrespective of their nature, the widespread application of radiation implies its precise dosimetric characterization and detailed knowledge of the radiobiological effects induced in cancerous and normal tissue. Starting with in vitro cell irradiation experiments, which define basic parameters for the subsequent tissue and animal studies, the whole multi-stage process is completed by clinical trials that translate the results of fundamental research into clinical application. In this context, the present dissertation focuses on the establishment of radiobiological in vitro cell experiments at unconventional, but clinical relevant radiation qualities. In the first part of the present work the energy dependent biological effectiveness of photons was studied examining low-energy X-rays (≤ 50 keV), as used for mammography, and high-energy photons (≥ 20 MeV) as proposed for future radiotherapy. Cell irradiation experiments have been performed at conventional X-ray tubes providing low-energy photons and 200 kV reference radiation as well. In parallel, unconventional quasi-monochromatic channeling X-rays and high-energy bremsstrahlung available at the radiation source ELBE of the Forschungszentrum Dresden-Rossendorf were considered for radiobiological experimentation. For their precise dosimetric characterization dosimeters based on the thermally stimulated emission of exoelectrons and on radiochromic films were evaluated, whereas just the latter was found to be suitable for the determination of absolute doses and spatial dose distributions at cell position. Standard ionization chambers were deployed for the online control of cell irradiation experiments. Radiobiological effects were analyzed in human mammary epithelial cells on different subcellular levels revealing an increasing amount

  10. Radiobiological and standard data for radioprotection and radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Jammet, H.

    1972-09-01

    From ninth annual meeting of the European Society for Radiation Biology; Rome, Italy (26 Sep 1972). Radiobiological data provide the scientific bases for radioprotection norms and radiotherapy practices. Nevertheless numerous problems remain unsolved including dosimetry at the cellular and infracellular level, metabolic curves for the purlfication of radionuclides, dose-effect relations for stochastic phenomena, effect of high doses on conjunctive tissue, value of the calibration factor in time, RBE of high energy particles, and radiosensitivity as a function of age and sex. The scope of these problems is briefly indicated. (JSR)

  11. Vibration Theory, Vol. 1B

    DEFF Research Database (Denmark)

    Asmussen, J. C.; Nielsen, Søren R. K.

    The present collection of MATLAB exercises has been published as a supplement to the textbook, Svingningsteori, Bind 1 and the collection of exercises in Vibration theory, Vol. 1A, Solved Problems. Throughout the exercise references are made to these books. The purpose of the MATLAB exercises is ...... is to give a better understanding of the physical problems in linear vibration theory and to surpress the mathematical analysis used to solve the problems. For this purpose the MATLAB environment is excellent....

  12. Influence of oxygen on the chemical stage of radiobiological mechanism

    Science.gov (United States)

    Barilla, Jiří; Lokajíček, Miloš V.; Pisaková, Hana; Simr, Pavel

    2016-07-01

    The simulation of the chemical stage of radiobiological mechanism may be very helpful in studying the radiobiological effect of ionizing radiation when the water radical clusters formed by the densely ionizing ends of primary or secondary charged particle may form DSBs damaging DNA molecules in living cells. It is possible to study not only the efficiency of individual radicals but also the influence of other species or radiomodifiers (mainly oxygen) being present in water medium during irradiation. The mathematical model based on Continuous Petri nets (proposed by us recently) will be described. It makes it possible to analyze two main processes running at the same time: chemical radical reactions and the diffusion of radical clusters formed during energy transfer. One may study the time change of radical concentrations due to the chemical reactions running during diffusion process. Some orientation results concerning the efficiency of individual radicals in DSB formation (in the case of Co60 radiation) will be presented; the influence of oxygen present in water medium during irradiation will be shown, too.

  13. An irradiation facility with a vertical beam for radiobiological studies

    CERN Document Server

    Besserer, J; Dellert, M; Gahn, C; Moosburger, M; Pemler, P; Quicken, P; Distel, L; Schuessler, H

    1999-01-01

    A vertical beam facility for radiobiological experiments was designed and constructed at the Munich Tandem-Accelerator Laboratory. The main part of the facility is a 90 deg. dipole magnet bending the beam of protons or heavy particles into a vertical upward direction, which is advantageous for wet-cell irradiation. After collimation the beam is spread out passively by thin scattering foils and dynamically by magnetic coils. A homogeneity of the radiation field better than +-5% has been achieved over the diameter of the exit window of 60 mm. The dose rate can be widely adjusted from single particles to more than 10 sup 1 sup 0 particles (i.e. hundreds of Grays) per second. The dose measurement is based on single-particle counting and on standard dosimeters. The detector system for dosimetry and irradiation control is described. In a first radiobiological experiment the cell survival of chinese hamster cells was measured after irradiation with 22.7 MeV protons and compared with the X-ray result.

  14. Radiobiologic comparison of helical tomotherapy, intensity modulated radiotherapy, and conformal radiotherapy in treating lung cancer accounting for secondary malignancy risks

    Energy Technology Data Exchange (ETDEWEB)

    Komisopoulos, Georgios [Department of Medical Physics, Medical School, University of Patras, Patras (Greece); Mavroidis, Panayiotis, E-mail: mavroidis@uthscsa.edu [Department of Radiation Oncology, University of Texas Health Sciences Center at San Antonio, San Antonio, TX (United States); Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm (Sweden); Rodriguez, Salvador; Stathakis, Sotirios; Papanikolaou, Nikos [Department of Radiation Oncology, University of Texas Health Sciences Center at San Antonio, San Antonio, TX (United States); Nikiforidis, Georgios C.; Sakellaropoulos, Georgios C. [Department of Medical Physics, Medical School, University of Patras, Patras (Greece)

    2014-01-01

    The aim of the present study is to examine the importance of using measures to predict the risk of inducing secondary malignancies in association with the clinical effectiveness of treatment plans in terms of tumor control and normal tissue complication probabilities. This is achieved by using radiobiologic parameters and measures, which may provide a closer association between clinical outcome and treatment delivery. Overall, 4 patients having been treated for lung cancer were examined. For each of them, 3 treatment plans were developed based on the helical tomotherapy (HT), multileaf collimator-based intensity modulated radiation therapy (IMRT), and 3-dimensional conformal radiation therapy (CRT) modalities. The different plans were evaluated using the complication-free tumor control probability (p{sub +}), the overall probability of injury (p{sub I}), the overall probability of control/benefit (p{sub B}), and the biologically effective uniform dose (D{sup ¯¯}). These radiobiologic measures were used to develop dose-response curves (p-D{sup ¯¯} diagram), which can help to evaluate different treatment plans when used in conjunction with standard dosimetric criteria. The risks for secondary malignancies in the heart and the contralateral lung were calculated for the 3 radiation modalities based on the corresponding dose-volume histograms (DVHs) of each patient. Regarding the overall evaluation of the different radiation modalities based on the p{sub +} index, the average values of the HT, IMRT, and CRT are 67.3%, 61.2%, and 68.2%, respectively. The corresponding average values of p{sub B} are 75.6%, 70.5%, and 71.0%, respectively, whereas the average values of p{sub I} are 8.3%, 9.3%, and 2.8%, respectively. Among the organs at risk (OARs), lungs show the highest probabilities for complications, which are 7.1%, 8.0%, and 1.3% for the HT, IMRT, and CRT modalities, respectively. Similarly, the biologically effective prescription doses (D{sub B}{sup ¯¯}) for the

  15. Characterization and performances of DOSION, a dosimetry equipment dedicated to radiobiology experiments taking place at GANIL

    CERN Document Server

    Boissonnat, G; Balanzat, E; Boumard, F; Carniol, B; Colin, J; Cussol, D; Etasse, D; Fontbonne, C; Frelin, A -M; Hommet, J; Peronnel, J; Salvador, S

    2016-01-01

    Currently, radiobiology experiments using heavy ions at GANIL(Grand Acc\\'el\\'erateur National d'Ions Lourds) are conducted under the supervision of the CIMAP (Center for research on Ions, MAterials and Photonics). In this context, a new beam monitoring equipment named DOSION has been developed. It allows to perform measurements of accurate fluence and dose maps in near real time for each biological sample irradiated. In this paper, we present the detection system, its design, performances, calibration protocol and measurements performed during radiobiology experiments. This setup is currently available for any radiobiology experiments if one wishes to correlate one's own sample analysis to state of the art dosimetric references.

  16. Operation and Maintenance of the National Radiobiology Archives

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Anthony C. James; Stacey L. McCord

    2012-03-07

    The National Radiobiology Archives (NRA) are an archival program, started in 1989, to collect, organize and maintain data, laboratory notebooks, and animal tissue specimens from government (Department of Energy and its predecessor agencies) sponsored radiobiology life-span animal studies. These unique records, histopathology slides and paraffin embedded tissue blocks are maintained in a central facility and are available for further research study. The materials include electronic and paper records for each of more than 6,000 life-span-observations on dogs as well as details of major studies involving nearly 30,000 mice. Although these studies were performed over many years and at different laboratories with differing data management systems, the NRA has translated them into a standardized set of relational database tables. These can be distributed to interested individuals on written request. Specific Aims are: (1) To Maintain the Archive of Written Records from the Animal Experiments - The USTUR continued to maintain the NRA archives which consist of approximately 175 storage boxes containing laboratory notebooks, animal exposure records, animal pathologic records, and radiographs. These were stored in a 6,000 square foot leased facility in Richland, WA. Additionally, through a collaboration with Pacific Northwest National Laboratory's (PNNL) Low Dose Program, many of these records were scanned into digital files. These totaled 34 GB of data, which are saved in 2,407 separate PDF files that are organized by box number and animal identification number. (2) To Maintain the Archive of Animal Tissues at Washington State University - The USTUR continued to house the NRA dog tissue collection in the leased facility. The NRA tissue collection consisted of pathology slides and tissue blocks. Approximately 25% of the laboratory facility was dedicated to the storage of the NRA materials. (3) To Organize the Datasets of These Animals in the Context of Other Datasets so

  17. Heavy ion radiobiology for hadrontherapy and space radiation protection.

    Science.gov (United States)

    Durante, Marco

    2004-12-01

    Research in the field of biological effects of heavy charged particles is needed for both heavy-ion therapy (hadrontherapy) and protection from the exposure to galactic cosmic radiation in long-term manned space missions. Although the exposure conditions (e.g. high- vs. low-dose rate) and relevant endpoints (e.g. cell killing vs. neoplastic transformation) are different in the two fields, it is clear that a substantial overlap exists in several research topics. Three such topics are discussed in this short review: individual radiosensitivity, mixed radiation fields, and late stochastic effects of heavy ions. In addition, researchers involved either in experimental studies on space radiation protection or heavy-ion therapy will basically use the same accelerator facilities. It seems to be important that novel accelerator facilities planned (or under construction) for heavy-ion therapy reserve a substantial amount of beamtime to basic studies of heavy-ion radiobiology and its applications in space radiation research.

  18. Method for validating radiobiological samples using a linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Brengues, Muriel [The University of Arizona College of Medicine, Center for Applied NanoBioscience and Medicine, Phoenix, AZ (United States); Liu, David; Korn, Ronald [Scottsdale Clinical Research Institute, Scottsdale Healthcare, Scottsdale, AZ (United States); Zenhausern, Frederic [The University of Arizona College of Medicine, Center for Applied NanoBioscience and Medicine, Phoenix, AZ (United States); Scottsdale Clinical Research Institute, Scottsdale Healthcare, Scottsdale, AZ (United States)

    2014-12-15

    There is an immediate need for rapid triage of the population in case of a large scale exposure to ionizing radiation. Knowing the dose absorbed by the body will allow clinicians to administer medical treatment for the best chance of recovery for the victim. In addition, today's radiotherapy treatment could benefit from additional information regarding the patient's sensitivity to radiation before starting the treatment. As of today, there is no system in place to respond to this demand. This paper will describe specific procedures to mimic the effects of human exposure to ionizing radiation creating the tools for optimization of administered radiation dosimetry for radiotherapy and/or to estimate the doses of radiation received accidentally during a radiation event that could pose a danger to the public. In order to obtain irradiated biological samples to study ionizing radiation absorbed by the body, we performed ex-vivo irradiation of human blood samples using the linear accelerator (LINAC). The LINAC was implemented and calibrated for irradiating human whole blood samples. To test the calibration, a 2 Gy test run was successfully performed on a tube filled with water with an accuracy of 3% in dose distribution. To validate our technique the blood samples were ex-vivo irradiated and the results were analyzed using a gene expression assay to follow the effect of the ionizing irradiation by characterizing dose responsive biomarkers from radiobiological assays. The response of 5 genes was monitored resulting in expression increase with the dose of radiation received. The blood samples treated with the LINAC can provide effective irradiated blood samples suitable for molecular profiling to validate radiobiological measurements via the gene-expression based biodosimetry tools. (orig.)

  19. A study of the radiobiological modeling of the conformal radiation therapy in cancer treatment

    Science.gov (United States)

    Pyakuryal, Anil Prasad

    Cancer is one of the leading causes of mortalities in the world. The precise diagnosis of the disease helps the patients to select the appropriate modality of the treatments such as surgery, chemotherapy and radiation therapy. The physics of X-radiation and the advanced imaging technologies such as positron emission tomography (PET) and computed tomography (CT) plays an important role in the efficient diagnosis and therapeutic treatments in cancer. However, the accuracy of the measurements of the metabolic target volumes (MTVs) in the PET/CT dual-imaging modality is always limited. Similarly the external beam radiation therapy (XRT) such as 3D conformal radiotherapy (3DCRT) and intensity modulated radiation therapy (IMRT) is the most common modality in the radiotherapy treatment. These treatments are simulated and evaluated using the XRT plans and the standard methodologies in the commercial planning system. However, the normal organs are always susceptible to the radiation toxicity in these treatments due to lack of knowledge of the appropriate radiobiological models to estimate the clinical outcomes. We explored several methodologies to estimate MTVs by reviewing various techniques of the target volume delineation using the static phantoms in the PET scans. The review suggests that the more precise and practical method of delineating PET MTV should be an intermediate volume between the volume coverage for the standardized uptake value (SUV; 2.5) of glucose and the 50% (40%) threshold of the maximum SUV for the smaller (larger) volume delineations in the radiotherapy applications. Similarly various types of optimal XRT plans were designed using the CT and PET/CT scans for the treatment of various types of cancer patients. The qualities of these plans were assessed using the universal plan-indices. The dose-volume criteria were also examined in the targets and organs by analyzing the conventional dose-volume histograms (DVHs). The biological models such as tumor

  20. A comparative analysis of radiobiological models for cell surviving fractions at high doses.

    Science.gov (United States)

    Andisheh, B; Edgren, M; Belkić, Dž; Mavroidis, P; Brahme, A; Lind, B K

    2013-04-01

    for the cell surviving fractions are exponentials at low as well as high doses, and this is in agreement with the behaviour of the corresponding experimental data. This is an important improvement over the LQ model which predicts a Gaussian at high doses. Overall and for the highlighted reasons, it was concluded that the PLQ, USC and LQL models are theoretically well-founded. They could prove useful compared to the other proposed radiobiological models in clinical applications for obtaining uniformly accurate cell surviving fractions encountered in stereotactic high-dose radiotherapy as well as at medium and low doses.

  1. Radiobiological mechanisms of stereotactic body radiation therapy and stereotactic radiation surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Sook; Kim, Won Woo; Park, In Hwan; Kim, Hee Jong; Lee, Eun Jin; Jung, Jae Hoon [Research Center for Radiotherapy, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Cho, Lawrence Chin Soo; Song, Chang W. [Dept. of Radiation Oncology, University of Minnesota Medical School, Minneapolis (United States)

    2015-12-15

    Despite the increasing use of stereotactic body radiation therapy (SBRT) and stereotactic radiation surgery (SRS) in recent years, the biological base of these high-dose hypo-fractionated radiotherapy modalities has been elusive. Given that most human tumors contain radioresistant hypoxic tumor cells, the radiobiological principles for the conventional multiple-fractionated radiotherapy cannot account for the high efficacy of SBRT and SRS. Recent emerging evidence strongly indicates that SBRT and SRS not only directly kill tumor cells, but also destroy the tumor vascular beds, thereby deteriorating intratumor microenvironment leading to indirect tumor cell death. Furthermore, indications are that the massive release of tumor antigens from the tumor cells directly and indirectly killed by SBRT and SRS stimulate anti-tumor immunity, thereby suppressing recurrence and metastatic tumor growth. The reoxygenation, repair, repopulation, and redistribution, which are important components in the response of tumors to conventional fractionated radiotherapy, play relatively little role in SBRT and SRS. The linear-quadratic model, which accounts for only direct cell death has been suggested to overestimate the cell death by high dose per fraction irradiation. However, the model may in some clinical cases incidentally do not overestimate total cell death because high-dose irradiation causes additional cell death through indirect mechanisms. For the improvement of the efficacy of SBRT and SRS, further investigation is warranted to gain detailed insights into the mechanisms underlying the SBRT and SRS.

  2. Amchitka Radiobiological Program progress report, January 1979-December 1979

    Energy Technology Data Exchange (ETDEWEB)

    Thornberg, L.D.; Sibley, T.H.; Nakatani, R.E.

    1980-07-01

    The objective of the Amchitka Radiobiological Program for the period 1970-1979 was to determine the extent of radionuclide contamination from world-wide atmospheric fallout and from the detonation of three underground nuclear blasts on Amchitka Island. The objective is achieved, by the collection and radiological analyses of biological and environmental samples and by background radiation measurements. Leakage of radionuclides from the underground sites of the Amchitka nuclear detonations would be suspected if the contamination was significntly greater than would be expected from world fallout. An account of the program from July 1970 to December 1978 has been given in nine previous reports from the Laboratory of Radiation Ecology to the Nevada Operations Office of the US Department of Energy. This report is an account of the program for calendar year 1979. The results of analyses of the samples collected in 1979 lead to the same conclusions as in previous years; i.e., there is no evidence that the radionuclide contamination at Amchitka Island is greater than would be expected from world fallout except for a slight contamination of the Long Shot Mud Pits with tritium.

  3. Fourier transform infrared microspectroscopy and multivariate methods for radiobiological dosimetry.

    Science.gov (United States)

    Meade, A D; Clarke, C; Byrne, H J; Lyng, F M

    2010-02-01

    The scientific literature contains an ever-growing number of reports of applications of vibrational spectroscopy as a multivariate non-invasive tool for analysis of biological effects at the molecular level. Recently, Fourier transform infrared microspectroscopy (FTIRM) has been demonstrated to be sensitive to molecular events occurring in cells and tissue after exposure to ionizing radiation. In this work the application of FTIRM in the examination of dose-dependent molecular effects occurring in skin cells after exposure to ionizing radiation with the use of partial least-squares regression (PLSR) and generalized regression neural networks (GRNN) was studied. The methodology is shown to be sensitive to molecular events occurring with radiation dose and time after exposure. The variation in molecular species with dose and time after irradiation is shown to be non-linear by virtue of the higher modeling efficiency yielded from the non-linear algorithms. Dose prediction efficiencies of approximately +/-10 mGy were achieved at 96 h after irradiation, highlighting the potential applications of the methodology in radiobiological dosimetry.

  4. Feasibility of BNCT radiobiological experiments at the HYTHOR facility

    Science.gov (United States)

    Esposito, J.; Ceballos, C.; Soncin, M.; Fabris, C.; Friso, E.; Moro, D.; Colautti, P.; Jori, G.; Rosi, G.; Nava, E.

    2008-06-01

    HYTHOR (HYbrid Thermal spectrum sHifter tapirO Reactor) is a new thermal-neutron irradiation facility, which was installed and became operative in mid 2005 at the TAPIRO (TAratura PIla Rapida potenza 0) fast reactor, in the Casaccia research centre (near Rome) of ENEA (Ente per le Nuove tecnologie Energia ed Ambiente). The facility has been designed for in vivo radiobiological studies. In HYTHOR irradiation cavity, 1-6 mice can be simultaneously irradiated to study skin melanoma treatments with the BNCT (boron neutron capture therapy). The therapeutic effects of HYTHOR radiation field on mouse melanoma has been studied as a preliminary investigation before studying the tumour local control due to boron neutron capture effect after boronated molecule injection. The method to properly irradiate small animals has been precisely defined. Results show that HYTHOR radiation field is by itself effective in reducing the tumour-growth rate. This finding has to be taken into account in studying the effectiveness of new 10B carriers. A method to properly measure the reduction of the tumour-growth rate is reported and discussed.

  5. Comparison of the radiobiological effect of carbon ion beam therapy and conventional radiation therapy on cervical cancer.

    Science.gov (United States)

    Suzuki, Yoshiyuki; Nakano, Takashi; Ohno, Tatsuya; Oka, Kuniyuki

    2008-09-01

    Little clinical evidence has been provided to show the minimization of radiation resistance of tumors using high linear energy transfer radiation. We therefore investigated the radiobiological and molecular pathological aspects of carbon beam therapy. A total of 27 patients with squamous cell carcinoma (SCC) of the cervix were treated using a carbon beam and 50 control patients with SCC of the cervix using a photon beam. The expression of Ki-67, p53, and p27 proteins before radiotherapy and 5 and 15 days after therapy initiation were investigated using immunohistochemistry. Similar changes were observed in Ki-67 labeling index (LI) and p53 LI during carbon and photon beam therapies. However, for carbon beam therapy, the mean p27 LI significantly decreased from 25.2% before treatment to 18.6% on the 5th day after treatment initiation, followed by a significant increase to 36.1% on the 15th day. In contrast, for photon beam therapy, the p27 LI consistently decreased from the initial 19.9% to 13.7% on the 15th day. Histological effects were observably stronger under carbon than photon beam therapy, though no statistically significant difference was observed (p = 0.07 on the 5th day and p = 0.10 on the 15th day). The changes in p27 LI under carbon beam therapy were significantly different from those under photon beam therapy, which suggests important molecular differences in the radio-biological response between therapies. Further investigation is required to elucidate the clinical relevance of these putative changes and optimize the relative biological effectiveness of carbon beam to X-ray.

  6. 77 FR 68155 - The Armed Forces Radiobiology Research Institute TRIGA Reactor: Facility Operating License No. R-84

    Science.gov (United States)

    2012-11-15

    ... COMMISSION The Armed Forces Radiobiology Research Institute TRIGA Reactor: Facility Operating License No. R... Operating License No. R-84 (Application), which currently authorizes the Armed Forces Radiobiology Research... the renewal of Facility Operating License No. R-84, which currently authorizes the licensee to...

  7. Single-Ion Microbeam for Applications in Radiobiology: State of the Art

    Institute of Scientific and Technical Information of China (English)

    Hu Zhiwen; Wu Lijun; Yu Zengliang

    2005-01-01

    Single-Ion Microbeam (SIM) is uniquely capable of precisely delivering a predefined number of charged particles (precise doses of radiation) to individual cells or sub-cellular targets in situ. Since the early 1990's, there has been an ever-increasing interest in developing and applying the SIM technique to problems in radiobiology for studies of cell and tissue damaged by ionizing radiations. Potential applications for SIM in radiobiology continues to grow and have been diversified. There are currently more than 14 SIM facilities worldwide, and they have been in a constant state of evolution. This paper reviews the current state of SIM research worldwide and the related pivotal technological developments in the fields of both biophysics and radiobiology.Representative applications and the perspective of SIM are also introduced and discussed.

  8. Development of applicable software containing radiobiological and physical indices to evaluate radiotherapy planning

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seu Ran; Suh, Tae Suk [Dept. of Biomedical Engineering, The Catholic University of Korea, Seoul (Korea, Republic of); Park, Ji Yeon [Molecular Imaging Program at Stanford, Stafnord University, Richmond (United States)

    2014-11-15

    Adaptive radiation therapy (ART) provides more conformal dose distribution to the morphologically and physiologically changed tumor volumes during fractionated radiation therapy (RT). To develop an enhanced treatment plan evaluation tool based on multi-modality imaging which incorporates physical and radiobiological parameters, the software system was developed using MATLAB v.7.10.0499 (The Mathworks, Inc., Natick, MA). The application of plan evaluation can help the user choose more biologically optimal treatment plans and potentially predict treatment outcome more accurately. The radiotherapy planning based on the multi-modality images had more accurate results than that of based on only CT images in both physical and radiobiological perspectives.

  9. Index to the Journal of American Indian Education, Vol. 1, No. 1 - Vol. 8, No. 1.

    Science.gov (United States)

    Loomis, Charlotte Ann

    All articles (112) that appeared in the "Journal of American Indian Education" (JAIE), Vol. 1., No. 1 (June 1961) through Vol. 8, No 1 (October 1968) are indexed and annotated. The publication is divided into 3 parts: (1) annotations listed in order of appearance in JAIE by volume, number, and page; (2) author index; and (3) subject index. Later…

  10. DEGRO practical guidelines for radiotherapy of non-malignant disorders. Part I: physical principles, radiobiological mechanisms, and radiogenic risk

    Energy Technology Data Exchange (ETDEWEB)

    Reichl, Berthold [Hospital Weiden, Department of Radiotherapy and Radiation Oncology, Weiden (Germany); Block, Andreas [Hospital Dortmund, Institute for Medical Radiation Physics and Radiation Protection, Dortmund (Germany); Schaefer, Ulrich [Lippe Hospital, Dept. of Radiotherapy, Lemgo (Germany); Bert, Christoph; Mueller, Reinhold [University Hospitals Erlangen, Dept. of Radiation Oncology, Erlangen (Germany); Jung, Horst [University Hospital Hamburg-Eppendorf, Dept. of Radiotherapy and Radiation Oncology, Hamburg (Germany); Roedel, Franz [University Hospital Goethe-University, Dept. of Radiotherapy and Oncology, Frankfurt am Main (Germany); Collaboration: the German Cooperative Group on Radiotherapy for Benign Diseases (GCG-BD)

    2015-09-15

    Synopsis of the introductory paragraph of the DEGRO consensus S2e-guideline recommendations for the radiotherapy of benign disorders, including physical principles, radiobiological mechanisms, and radiogenic risk. This work is based on the S2e-guideline recommendations published November 14, 2013. The basic principles of radiation physics and treatment delivery, evaluation of putative underlying radiobiological mechanisms, and the assessment of genetic and cancer risk following low-dose irradiation will be presented. Radiation therapy of benign diseases is performed according to similar physical principles as those governing treatment of malignant diseases in radiation oncology, using the same techniques and workflows. These methods comprise usage of orthovoltage X-ray units, gamma irradiation facilities, linear accelerators (LINACs), and brachytherapy. Experimental in vitro and in vivo models recently confirmed the clinically observed anti-inflammatory effect of low-dose X-irradiation, and implicated a multitude of radiobiological mechanisms. These include modulation of different immunological pathways, as well as the activities of endothelial cells, mono- and polymorphonuclear leukocytes, and macrophages. The use of effective dose for radiogenic risk assessment and the corresponding tumor incidence rate of 5.5 %/Sv are currently controversially discussed. Some authors argue that the risk of radiation-induced cancers should be estimated on the basis of epidemiological data. However, such data are rarely available at present and associated with high variability. Current radiobiological studies clearly demonstrate a therapeutic effectiveness of radiation therapy used to treat benign diseases and implicate various molecular mechanisms. Radiogenic risks should be taken into account when applying radiation treatment for benign diseases. (orig.) [German] Zusammenfassung des einfuehrenden Kapitels der DEGRO-S2e-Leitlinie zur Strahlentherapie gutartiger Erkrankungen

  11. Radiobiological effects of heavy ions and protons. [on cells of mammals, bacteria and viruses

    Science.gov (United States)

    Ryzhov, N. I.; Vorozhtsova, S. V.; Krasavin, Y. A.; Mashinskaya, T. Y.; Savchenko, N. Y.; Fedorov, B. S.; Khlaponina, V. F.; Shelegedin, V. N.; Gut, L.; Sabo, L.

    1974-01-01

    Radiobiological effects of heavy ions and protons are studied on cells of mammals, bacteria, viruses and DNA of bacteria. Results show that the dose effect dependence bears an exponential character; the reduction of RBE as LET of particle increases reflects the different character of microdistribution of absorbed energy in biological objects with different levels of biological organization.

  12. A community call for a dedicated radiobiological research facility to support particle beam cancer therapy

    DEFF Research Database (Denmark)

    Holzscheiter, Michael H.; Bassler, Niels; Dosanjh, Manjit;

    2012-01-01

    Recently more than one hundred researchers followed an invitation to a brainstorming meeting on the topic of a future dedicated radio-biological and radio-physical research center. 100 more joint the meeting via webcast. After a day of presentations and discussions it was clear, that an urgent need...

  13. Cuba's National Clinical Trials Coordinating Center: emergence, evolution, and main results. Translated from the Spanish and reprinted with permission from the Revista Cubana de Farmacia. Vol. 44 No. 2 (special supplement), Apr-Jun 2010.

    Science.gov (United States)

    López, María A Pascual; Rivero, Gladys Jiménez; Pombert, Ania Torres; López, Martha María Fors; Zayas, Isabel López

    2011-01-01

    The rapid development of Cuba's pharmaceutical industry in the 1990s created a need for structures to ensure clinical evaluation of products before their introduction into medical practice and subsequent marketing. One of the centers founded for this purpose was the National Clinical Trials Coordinating Center. This paper summarizes the factors that motivated the creation of the Center and presents a brief history of its organizational development over the last 17 years. It also describes the main components of the system for designing and conducting clinical trials, and the most significant contributions of each toward achieving the Center's objectives.

  14. Paul Scherrer Institut annual report 1995. Annex II: PSI life sciences and institute for medical radiobiology newsletter 1995

    Energy Technology Data Exchange (ETDEWEB)

    Blaeuenstein, P.; Gschwend, B. [eds.

    1996-09-01

    The newsletter presents the 1995 progress report of PSI F2-Department and of the Institute for Medical Radiobiology in the fields of radiation medicine, radiopharmacy and radiation hygiene. figs., tabs., refs.

  15. Crisis Communication (Handbooks of Communication Science Vol. 23)

    DEFF Research Database (Denmark)

    Vol. 23 - The Handbook of Communication Science General editors: Peter J. Schultz and Paul Cobley......Vol. 23 - The Handbook of Communication Science General editors: Peter J. Schultz and Paul Cobley...

  16. Three-dimensional radiobiological dosimetry of kidneys for treatment planning in peptide receptor radionuclide therapy

    Energy Technology Data Exchange (ETDEWEB)

    Baechler, Sebastien; Hobbs, Robert F.; Boubaker, Ariane; Buchegger, Franz; He Bin; Frey, Eric C.; Sgouros, George [Institute of Radiation Physics, Lausanne University Hospital, 1007 Lausanne (Switzerland); Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231 (United States); Department of Nuclear Medicine, Lausanne University Hospital, 1011 Lausanne (Switzerland); Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University, School of Medicine, Baltimore, Maryland 21231 (United States)

    2012-10-15

    Purpose: Peptide receptor radionuclide therapy (PRRT) delivers high absorbed doses to kidneys and may lead to permanent nephropathy. Reliable dosimetry of kidneys is thus critical for safe and effective PRRT. The aim of this work was to assess the feasibility of planning PRRT based on 3D radiobiological dosimetry (3D-RD) in order to optimize both the amount of activity to administer and the fractionation scheme, while limiting the absorbed dose and the biological effective dose (BED) to the renal cortex. Methods: Planar and SPECT data were available for a patient examined with {sup 111}In-DTPA-octreotide at 0.5 (planar only), 4, 24, and 48 h post-injection. Absorbed dose and BED distributions were calculated for common therapeutic radionuclides, i.e., {sup 111}In, {sup 90}Y and {sup 177}Lu, using the 3D-RD methodology. Dose-volume histograms were computed and mean absorbed doses to kidneys, renal cortices, and medullae were compared with results obtained using the MIRD schema (S-values) with the multiregion kidney dosimetry model. Two different treatment planning approaches based on (1) the fixed absorbed dose to the cortex and (2) the fixed BED to the cortex were then considered to optimize the activity to administer by varying the number of fractions. Results: Mean absorbed doses calculated with 3D-RD were in good agreement with those obtained with S-value-based SPECT dosimetry for {sup 90}Y and {sup 177}Lu. Nevertheless, for {sup 111}In, differences of 14% and 22% were found for the whole kidneys and the cortex, respectively. Moreover, the authors found that planar-based dosimetry systematically underestimates the absorbed dose in comparison with SPECT-based methods, up to 32%. Regarding the 3D-RD-based treatment planning using a fixed BED constraint to the renal cortex, the optimal number of fractions was found to be 3 or 4, depending on the radionuclide administered and the value of the fixed BED. Cumulative activities obtained using the proposed simulated

  17. SU-E-T-275: Radiobiological Evaluation of Intensity Modulated Radiotherapy Treatment for Locally Advanced Head and Neck Squamous Cell Carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Rekha Reddy, B.; Ravikumar, M.; Tanvir Pasha, C.R; Anil Kumar, M.R; Varatharaj, C. [Kidwai Memorial Institute of Oncology Bangalore, Karnataka (India); Pyakuryal, A [University Illinois at Chicago, Chicago, IL (United States); Narayanasamy, Ganesh [UTHSCSA, San Antonio, TX (United States)

    2014-06-01

    Purpose: To evaluate the radiobiological outcome of Intensity Modulated Radiotherapy Treatment (IMRT) for locally advanced head and neck squamous cell carcinomas using HART (Histogram Analysis in Radiation Therapy; J Appl Clin Med Phys 11(1): 137–157, 2010) program and compare with the clinical outcomes. Methods: We have treated 20 patients of stage III and IV HNSCC Oropharynx and hypopharynx with accelerated IMRT technique and concurrent chemotherapy. Delineation of tumor and normal tissues were done using Danish Head and Neck Cancer Group (DAHANCA) contouring guidelines and radiotherapy was delivered to a dose of 70Gy in 35 fractions to the primary and involved lymph nodes, 63Gy to intermediate risk areas and 56 Gy to lower risk areas, Monday to Saturday, 6 Days/week using 6 MV Photons with an expected overall treatment time of 6 weeks. The TCP and NTCP's were calculated from the dose-volume histogram (DVH) statistics using the Poisson Statistics (PS) and JT Lyman models respectively and the Resultwas correlated with clinical outcomes of the patients with mean follow up of 24 months. Results: Using HART program, the TCP (0.89± 0.01) of primary tumor and the NTCP for parotids (0.20±0.12), spinal cord (0.05±0.01), esophagus (0.30±0.2), mandible (0.35±0.21), Oral cavity (0.37±0.18), Larynx (0.30±0.15) were estimated and correlated with clinical outcome of the patients. Conclusion: Accelerated IMRT with Chemotherapy is a clinical feasible option in the treatment of locally advanced HNSCC with encouraging initial tumour response and acceptable acute toxicities. The correlation between the clinical outcomes and radiobiological model estimated parameters using HART programs are found to be satisfactory.

  18. Effects of radiobiological uncertainty on shield design for a 60-day lunar mission

    Science.gov (United States)

    Wilson, John W.; Nealy, John E.; Schimmerling, Walter

    1993-01-01

    Some consequences of uncertainties in radiobiological risk due to galactic cosmic ray exposure are analyzed to determine their effect on engineering designs for a first lunar outpost - a 60-day mission. Quantitative estimates of shield mass requirements as a function of a radiobiological uncertainty factor are given for a simplified vehicle structure. The additional shield mass required for compensation is calculated as a function of the uncertainty in galactic cosmic ray exposure, and this mass is found to be as large as a factor of 3 for a lunar transfer vehicle. The additional cost resulting from this mass is also calculated. These cost estimates are then used to exemplify the cost-effectiveness of research.

  19. Ill-posed problem and regularization in reconstruction of radiobiological parameters from serial tumor imaging data

    Science.gov (United States)

    Chvetsov, Alevei V.; Sandison, George A.; Schwartz, Jeffrey L.; Rengan, Ramesh

    2015-11-01

    The main objective of this article is to improve the stability of reconstruction algorithms for estimation of radiobiological parameters using serial tumor imaging data acquired during radiation therapy. Serial images of tumor response to radiation therapy represent a complex summation of several exponential processes as treatment induced cell inactivation, tumor growth rates, and the rate of cell loss. Accurate assessment of treatment response would require separation of these processes because they define radiobiological determinants of treatment response and, correspondingly, tumor control probability. However, the estimation of radiobiological parameters using imaging data can be considered an inverse ill-posed problem because a sum of several exponentials would produce the Fredholm integral equation of the first kind which is ill posed. Therefore, the stability of reconstruction of radiobiological parameters presents a problem even for the simplest models of tumor response. To study stability of the parameter reconstruction problem, we used a set of serial CT imaging data for head and neck cancer and a simplest case of a two-level cell population model of tumor response. Inverse reconstruction was performed using a simulated annealing algorithm to minimize a least squared objective function. Results show that the reconstructed values of cell surviving fractions and cell doubling time exhibit significant nonphysical fluctuations if no stabilization algorithms are applied. However, after applying a stabilization algorithm based on variational regularization, the reconstruction produces statistical distributions for survival fractions and doubling time that are comparable to published in vitro data. This algorithm is an advance over our previous work where only cell surviving fractions were reconstructed. We conclude that variational regularization allows for an increase in the number of free parameters in our model which enables development of more

  20. The impact of modeling nuclear fragmentation on delivered dose and radiobiology in ion therapy.

    Science.gov (United States)

    Lühr, Armin; Hansen, David C; Teiwes, Ricky; Sobolevsky, Nikolai; Jäkel, Oliver; Bassler, Niels

    2012-08-21

    The importance of nuclear interactions for ion therapy arises from the influence of the particle spectrum on, first, radiobiology and therefore also on treatment planning, second, the accuracy of measuring dose and, third, the delivered dose distribution. This study tries to determine the qualitative as well as the quantitative influence of the modeling of inelastic nuclear interactions on ion therapy. Thereby, three key disciplines are investigated, namely dose delivery, dose assessment and radiobiology. In order to perform a quantitative analysis, a relative comparison between six different descriptions of nuclear interactions is carried out for carbon ions. The particle transport is simulated with the Monte Carlo code SHIELD-HIT10A while dose planning and radiobiology are covered by the analytic treatment planning program for particles TRiP, which determines the relative biological effectiveness (RBE) with the local effect model. The obtained results show that the physical dose distribution can in principle be significantly influenced by the modeling of fragmentation (about 10% for a 20% change in all inelastic nuclear cross sections for a target volume ranging from 15 to 25 cm). While the impact of nuclear fragmentation on stopping power ratios can be neglected, the fluence correction factor may be influenced by the applied nuclear models. In contrast to the results for the physical dose, the variation of the RBE is only small (about 1% for a 20% change in all inelastic nuclear cross sections) suggesting a relatively weak dependence of radiobiology on the detailed composition of the particle energy spectrum of the mixed radiation field. Also, no significant change (about 0.2 mm) of the lateral penumbra of the RBE-weighted dose is observed.

  1. Modeling detector response in solid-state systems for radiation therapy and radiobiology

    Energy Technology Data Exchange (ETDEWEB)

    Hugtenburg, R.P. [School of Physics and Astronomy, University of Birmingham, B15 2TT, UK (United Kingdom); Bradley, D.A. [Department of Physics, University of Surrey, Guildford, GU2 7XH, UK (United Kingdom)

    2006-07-01

    In order for the many advantageous properties of solid-state dosimeters to be realised in clinic, strategies must be evolved for the calibration of detector systems for an ever expanding range of radiation sources including spectrally complex and mixed radiation fields. Monte Carlo models of the source and detector systems provide a means to account in a precise way for energy absorbed in the detector allowing for primary and secondary radiation processes including multiple scattering. Solid- state dosimeters including Si diodes, MOSFET, diamond detectors and doped optical fibres have been calibrated for dose in monoenergetic synchrotron X-rays in the range 5-50 keV, for quasi monoenergetic X-rays sources from 20-200 keV and for megavoltage X-ray and proton sources, such as are used in radical radiation therapy. With careful consideration of the elemental composition of the detector it is possible to achieve high quality agreement (2-3%) between measurement and Monte Carlo models of the variation of the detector response over a wide energy range. This information is needed in radiation therapy dosimetry where, for large external X-ray beams, detectors see a mixture of high energy primary photons and low energy (e.g. Compton scattered and pair-production-annihilation) photons. Typically, for solid-state detectors, different cavity theories are required for the two energy groups. In addition, high-Z constituents in detectors lead to an enhanced photoelectric absorption, which in the case of pure silicon detectors is up to 8 times greater than the tissue equivalent response. Information from maps of the elemental composition in the detectors, obtained via XRF and PIXE, is used in the models. Monte Carlo models are also being developed for contributions to the response from electron transport, including the microdosimetric response of detectors. Current Monte Carlo codes are able to handle large variations in density that typify tissue equivalent gas

  2. Fast neutrons set the pace. [Radiobiological investigations with fast neutrons at the CSIR cyclotron in Pretoria

    Energy Technology Data Exchange (ETDEWEB)

    Hough, J.H.; Slabbert, J.P. (Council for Scientific and Industrial Research, Pretoria (South Africa). National Accelerator Centre)

    1985-01-01

    Radiobiological investigations with fast neutrons have been initiated at the CSIR cyclotron in Pretoria. It was proposed some years ago to create a neutron therapy facility using the CSIR cyclotron. Neutrons are classified as high linear energy transfer (LET) particles. Biological damage occurring in tissue is a direct function of the LET of the incident radiation. To quantify the biological effects of different types of radiation on mammalian cells, several procedures and concepts have evolved from radiobiological research. Probably the most significant laboratory techniques developed, were the derivation of cell survival curves which are obtained by determining the number of cell colonies that have survived a certain radiation dose. A semi-logarithmic plot of surviving fraction versus the absorbed dose yields the survival curve. Dose modifying factors such as the relative biological effectiveness (RBE) of the radiation can be quantified in terms of this relationship. A radiobiological programme has to be undertaken before patients can receive neutron therapy at the CSIR cyclotron. The article is a discussion of this programme.

  3. volBrain: an online MRI brain volumetry system

    Directory of Open Access Journals (Sweden)

    Jose V. Manjon

    2016-07-01

    Full Text Available The amount of medical image data produced in clinical and research settings is rapidly growing resulting in vast amount of data to analyze. Automatic and reliable quantitative analysis tools, including segmentation, allow to analyze brain development and to understand specific patterns of many neurological diseases. This field has recently experienced many advances with successful techniques based on non-linear warping and label fusion. In this work we present a novel and fully automatic pipeline for volumetric brain analysis based on multi-atlas label fusion technology that is able to provide accurate volumetric information at different levels of detail in a short time. This method is available through the volBrain online web interface (http://volbrain.upv.es, which is publically and freely accessible to the scientific community. Our new framework has been compared with current state-of-the-art methods showing very competitive results.

  4. El espectro de K2 Vol

    Science.gov (United States)

    Pintado, O. I.; Adelman, S. J.

    Se han obtenido espectros de alta dispersión para la estrella K2 Vol con el espectrógrafo REOSC del CASLEO en un rango de longitudes de ondas comprendido entre 3500 y 5050 Å. El espectro muestra evidencias de que la estrella es binaria. Se determinan las abundancias de los componentes químicos presentes en su atmósfera, como así también algunas características de su compañera.

  5. Hypo-fractionated treatment in radiotherapy: radio-biological models Tcp and NTCP; Tratamiento hipofraccionado en radioterapia: modelos radiobiologicos TCP y NTCP

    Energy Technology Data Exchange (ETDEWEB)

    Astudillo V, A. J.; Mitsoura, E. [Universidad Autonoma del Estado de Mexico, Facultad de Medicina, Paseo Tollocan s/n, 50180 Toluca, Estado de Mexico (Mexico); Paredes G, L. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Resendiz G, G., E-mail: lydia.paredes@inin.gob.mx [Hospital Medica Sur, Departamento de Radioterapia, Puente de Piedra 150, Col. Toriello Guerra, 14050 Mexico D. F. (Mexico)

    2014-08-15

    At the present time the breast cancer in Mexico has the first place of incidence of the malignant neoplasia s in the women, and represents 11.34% of all the cancer cases. On the other hand, the treatments for cancer by means of ionizing radiations have been dominated under the approaches of the medical radio-oncologists which have been based on test and error by many years. The radio-biological models, as the Tcp, NTCP and dosimetric variables, for their clinical application in the conventional radiotherapy with hypo-fractionation have as purpose predicting personalized treatment plans that they present most probability of tumor control and minor probability of late reactions, becoming this way support tools in the decisions taking for the patient treatments planning of Medical Physicists and Radio-oncologists. (Author)

  6. [SMEAC Newsletters, Science Education, Vol. 1, No. 1--Vol. 2, No. 1, 1967-1968].

    Science.gov (United States)

    ERIC Clearinghouse for Science, Mathematics, and Environmental Education, Columbus, OH.

    Each of these newsletters, produced by the ERIC Information Analysis Center for Science, Mathematics, and Environmental Education, contains information concerning center publications and other items considered of interest to researchers and educators of various education levels. Vol. 1, No. 1 highlights selected bibliographies (no longer produced…

  7. [SMEAC Newsletters, Science Education, Vol. 2, No. 2--Vol. 2, No. 3, 1969].

    Science.gov (United States)

    ERIC Clearinghouse for Science, Mathematics, and Environmental Education, Columbus, OH.

    Each of these newsletters, produced by the ERIC Information Analysis Center for Science, Mathematics, and Environmental Education, Contains information concerning center publications and activities, as well as other items considered of interest to researchers and educators of various educational levels. One of the emphases in Vol. 2, No. 2, is a…

  8. Development of a compact laser-produced plasma soft X-ray source for radiobiology experiments

    Science.gov (United States)

    Adjei, Daniel; Ayele, Mesfin Getachew; Wachulak, Przemyslaw; Bartnik, Andrzej; Wegrzynski, Łukasz; Fiedorowicz, Henryk; Vyšín, Luděk; Wiechec, Anna; Lekki, Janusz; Kwiatek, Wojciech M.; Pina, Ladislav; Davídková, Marie; Juha, Libor

    2015-12-01

    A desk-top laser-produced plasma (LPP) source of soft X-rays (SXR) has been developed for radiobiology research. The source is based on a double-stream gas puff target, irradiated with the focused beam of a commercial Nd:YAG laser. The source has been optimized to get a maximum photon emission from LPP in the X-ray "water window" spectral wavelength range from 2.3 nm (i.e., an absorption edge of oxygen) to 4.4 nm (i.e., an absorption edge of carbon) (280-540 eV in photon energy units) by using argon gas-puff target and spectral filtering by free-standing thin foils. The present source delivers nanosecond pulses of soft X-rays at a fluence of about 4.2 × 103 photons/μm2/pulse on a sample placed inside the vacuum chamber. In this paper, the source design, radiation output characterization measurements and initial irradiation experiments are described. The source can be useful in addressing observations related to biomolecular, cellular and organisms' sensitivity to pulsed radiation in the "water window", where carbon atoms absorb X-rays more strongly than the oxygen, mostly present in water. The combination of the SXR source and the radiobiology irradiation layout, reported in this article, make possible a systematic investigation of relationships between direct and indirect action of ionizing radiation, an increase of a local dose in carbon-rich compartments of the cell (e.g., lipid membranes), an experimental estimation of a particular role of the Auger effect (in particular in carbon atoms) in the damage to biological systems, and the study of ionization/excitation-density (LET - Linear Energy Transfer) and dose-rate effects in radiobiology.

  9. Issues for Simulation of Galactic Cosmic Ray Exposures for Radiobiological Research at Ground Based Accelerators

    Directory of Open Access Journals (Sweden)

    Myung-Hee Y Kim

    2015-06-01

    Full Text Available For research on the health risks of galactic cosmic rays (GCR ground-based accelerators have been used for radiobiology research with mono-energetic beams of single high charge, Z and energy, E (HZE particles. In this paper we consider the pros and cons of a GCR reference field at a particle accelerator. At the NASA Space Radiation Laboratory (NSRL we have proposed a GCR simulator, which implements a new rapid switching mode and higher energy beam extraction to 1.5 GeV/u, in order to integrate multiple ions into a single simulation within hours or longer for chronic exposures. After considering the GCR environment and energy limitations of NSRL, we performed extensive simulation studies using the stochastic transport code, GERMcode (GCR Event Risk Model to define a GCR reference field using 9 HZE particle beam-energy combinations each with a unique absorber thickness to provide fragmentation and 10 or more energies of proton and 4He beams. The reference field is shown to well represent the charge dependence of GCR dose in several energy bins behind shielding compared to a simulated GCR environment. However a more significant challenge for space radiobiology research is to consider chronic GCR exposure of up to 3 years in relation to simulations with animal models of human risks. We discuss issues in approaches to map important biological time scales in experimental models using ground-based simulation with extended exposure of up to a few weeks using chronic or fractionation exposures. A kinetics model of HZE particle hit probabilities suggests that experimental simulations of several weeks will be needed to avoid high fluence rate artifacts, which places limitations on the experiments to be performed. Ultimately risk estimates are limited by theoretical understanding, and focus on improving understanding of mechanisms and development of experimental models to improve this understanding should remain the highest priority for space radiobiology

  10. Development of a compact laser-produced plasma soft X-ray source for radiobiology experiments

    Energy Technology Data Exchange (ETDEWEB)

    Adjei, Daniel, E-mail: nana.adjeidan@gmail.com [Institute of Optoelectronics, Military University of Technology, 2, Kaliskiego Str., 00-908 Warsaw (Poland); Radiation Protection Institute, Ghana Atomic Energy Commission, P.O. Box LG 80, Legon, Accra (Ghana); Ayele, Mesfin Getachew; Wachulak, Przemyslaw; Bartnik, Andrzej; Wegrzynski, Łukasz; Fiedorowicz, Henryk [Institute of Optoelectronics, Military University of Technology, 2, Kaliskiego Str., 00-908 Warsaw (Poland); Vyšín, Luděk [Institute of Physics, Czech Academy of Sciences, Na Slovance 2, 182 21 Prague 8 (Czech Republic); Faculty of Nuclear Sciences and Engineering Physics, Czech Technical University in Prague, Břehová 7, 115 19 Prague 1 (Czech Republic); Wiechec, Anna; Lekki, Janusz; Kwiatek, Wojciech M. [Institute of Nuclear Physics, Polish Academy of Sciences, 152, Radzikowskiego Str., 31-342 Cracow (Poland); Pina, Ladislav [Faculty of Nuclear Sciences and Engineering Physics, Czech Technical University in Prague, Břehová 7, 115 19 Prague 1 (Czech Republic); Davídková, Marie [Institute of Nuclear Physics, Czech Academy of Sciences, Řež (Czech Republic); Juha, Libor [Institute of Physics, Czech Academy of Sciences, Na Slovance 2, 182 21 Prague 8 (Czech Republic)

    2015-12-01

    A desk-top laser-produced plasma (LPP) source of soft X-rays (SXR) has been developed for radiobiology research. The source is based on a double-stream gas puff target, irradiated with the focused beam of a commercial Nd:YAG laser. The source has been optimized to get a maximum photon emission from LPP in the X-ray “water window” spectral wavelength range from 2.3 nm (i.e., an absorption edge of oxygen) to 4.4 nm (i.e., an absorption edge of carbon) (280–540 eV in photon energy units) by using argon gas-puff target and spectral filtering by free-standing thin foils. The present source delivers nanosecond pulses of soft X-rays at a fluence of about 4.2 × 10{sup 3} photons/μm{sup 2}/pulse on a sample placed inside the vacuum chamber. In this paper, the source design, radiation output characterization measurements and initial irradiation experiments are described. The source can be useful in addressing observations related to biomolecular, cellular and organisms’ sensitivity to pulsed radiation in the “water window”, where carbon atoms absorb X-rays more strongly than the oxygen, mostly present in water. The combination of the SXR source and the radiobiology irradiation layout, reported in this article, make possible a systematic investigation of relationships between direct and indirect action of ionizing radiation, an increase of a local dose in carbon-rich compartments of the cell (e.g., lipid membranes), an experimental estimation of a particular role of the Auger effect (in particular in carbon atoms) in the damage to biological systems, and the study of ionization/excitation-density (LET – Linear Energy Transfer) and dose-rate effects in radiobiology.

  11. Tcp and NTCP radiobiological models: conventional and hypo fractionated treatments in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Astudillo V, A.; Paredes G, L. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Resendiz G, G.; Posadas V, A. [Hospital Angeles Lomas, Av. Vialidad de la Barranca s/n, Col. Valle de las Palmas, 52763 Huixquilucan de Degallado, Estado de Mexico (Mexico); Mitsoura, E. [Universidad Autonoma del Estado de Mexico, Facultad de Medicina, Paseo Tollocan, Esq. Jesus Carranza s/n, Col. Moderna de la Cruz, 50180 Toluca, Estado de Mexico (Mexico); Rodriguez L, A.; Flores C, J. M., E-mail: armando.astudillo@inin.gob.mx [Hospital Medica Sur, Puente de Piedra 150, Col. Toriello Guerra, 14050 Tlalpan, Mexico D. F. (Mexico)

    2015-10-15

    The hypo and conventional fractionated schedules performance were compared in terms of the tumor control and the normal tissue complications. From the records of ten patients, treated for adenocarcinoma and without mastectomy, the dose-volume histogram was used. Using radiobiological models the probabilities for tumor control and normal tissue complications were calculated. For both schedules the tumor control was approximately the same. However, the damage in the normal tissue was larger in conventional fractionated schedule. This is important because patients assistance time to their fractions (15 fractions/25 fractions) can be optimized. Thus, the hypo fractionated schedule has suitable characteristics to be implemented. (Author)

  12. The new hybrid thermal neutron facility at TAPIRO reactor for BNCT radiobiological experiments.

    Science.gov (United States)

    Esposito, J; Rosi, G; Agosteo, S

    2007-01-01

    A new thermal neutron irradiation facility, devoted to carry out both dosimetric and radiobiological studies on boron carriers, which are being developed in the framework of INFN BNCT project, has been installed at the ENEA Casaccia TAPIRO research fast reactor. The thermal column, based on an original, hybrid, neutron spectrum shifter configuration, has been recently become operative. In spite of its low power (5 kW), the new facility is able to provide a high thermal neutron flux level, uniformly distributed inside the irradiation cavity, with a quite low gamma background. The main features and preliminary benchmark measurements of the Beam-shaping assembly are here presented and discussed.

  13. Heavy-ion radiobiology: new approaches to delineate mechanisms underlying enhanced biological effectiveness.

    Science.gov (United States)

    Blakely, E A; Kronenberg, A

    1998-11-01

    Shortly after the discovery of polonium and radium by Marie Curie and her husband and colleague, Pierre Curie, it was learned that exposure to these alpha-particle emitters produced deleterious biological effects. The mechanisms underlying the increased biological effectiveness of densely ionizing radiations, including alpha particles, neutrons and highly energetic heavy charged particles, remain an active area of investigation. In this paper, we review recent advances in several areas of the radiobiology of these densely ionizing radiations, also known as heavy ions. Advances are described in the areas of DNA damage and repair, chromosome aberrations, mutagenesis, neoplastic transformation in vitro, genomic instability, normal tissue radiobiology and carcinogenesis in vivo. We focus on technical innovations, including novel applications of pulsed-field gel electrophoresis, fluorescence in situ hybridization (FISH), linkage analysis, and studies of gene expression and protein expression. We also highlight the use of new cellular and animal systems, including those with defined DNA repair deficiencies, as well as epithelial cell model systems to assess neoplastic transformation both in vitro and in vivo. The studies reviewed herein have had a substantial impact on our understanding of the genotoxic effects of heavy ions as well as their distinct effects on tissue homeostasis. The use of these radiations in cancer therapy is also discussed. The use of both heavy-ion and proton therapy is on the upswing in several centers around the world, due to their unique energy deposition characteristics that enhance the therapeutic effect and help reduce damage to normal tissue.

  14. Heavy-ion radiobiology: new approaches to delineate mechanisms underlying enhanced biological effectiveness

    Science.gov (United States)

    Blakely, E. A.; Kronenberg, A.; Chatterjee, A. (Principal Investigator)

    1998-01-01

    Shortly after the discovery of polonium and radium by Marie Curie and her husband and colleague, Pierre Curie, it was learned that exposure to these alpha-particle emitters produced deleterious biological effects. The mechanisms underlying the increased biological effectiveness of densely ionizing radiations, including alpha particles, neutrons and highly energetic heavy charged particles, remain an active area of investigation. In this paper, we review recent advances in several areas of the radiobiology of these densely ionizing radiations, also known as heavy ions. Advances are described in the areas of DNA damage and repair, chromosome aberrations, mutagenesis, neoplastic transformation in vitro, genomic instability, normal tissue radiobiology and carcinogenesis in vivo. We focus on technical innovations, including novel applications of pulsed-field gel electrophoresis, fluorescence in situ hybridization (FISH), linkage analysis, and studies of gene expression and protein expression. We also highlight the use of new cellular and animal systems, including those with defined DNA repair deficiencies, as well as epithelial cell model systems to assess neoplastic transformation both in vitro and in vivo. The studies reviewed herein have had a substantial impact on our understanding of the genotoxic effects of heavy ions as well as their distinct effects on tissue homeostasis. The use of these radiations in cancer therapy is also discussed. The use of both heavy-ion and proton therapy is on the upswing in several centers around the world, due to their unique energy deposition characteristics that enhance the therapeutic effect and help reduce damage to normal tissue.

  15. Past and Future Work on Radiobiology Mega-Studies: A Case Study At Argonne National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Haley, Benjamin; Wang, Qiong; Wanzer, Beau; Vogt, Stefan; Finney, Lydia; Yang, Ping Liu; Paunesku, Tatjana; Woloschak, Gayle

    2011-09-06

    Between 1952 and 1992, more than 200 large radiobiology studies were conducted in research institutes throughout Europe, North America, and Japan to determine the effects of external irradiation and internal emitters on the lifespan and tissue toxicity development in animals. At Argonne National Laboratory, 22 external beam studies were conducted on nearly 700 beagle dogs and 50,000 mice between 1969 and 1992. These studies helped to characterize the effects of neutron and gamma irradiation on lifespan, tumorigenesis, and mutagenesis across a range of doses and dosing patterns. The records and tissues collected at Argonne during that time period have been carefully preserved and redisseminated. Using these archived data, ongoing statistical work has been done and continues to characterize quality of radiation, dose, dose rate, tissue, and gender-specific differences in the radiation responses of exposed animals. The ongoing application of newly-developed molecular biology techniques to the archived tissues has revealed gene-specific mutation rates following exposure to ionizing irradiation. The original and ongoing work with this tissue archive is presented here as a case study of a more general trend in the radiobiology megastudies. These experiments helped form the modern understanding of radiation responses in animals and continue to inform development of new radiation models. Recent archival efforts have facilitated open access to the data and materials produced by these studies, and so a unique opportunity exists to expand this continued research.

  16. A radiobiological model of radiotherapy response and its correlation with prognostic imaging variables

    Science.gov (United States)

    Crispin-Ortuzar, Mireia; Jeong, Jeho; Fontanella, Andrew N.; Deasy, Joseph O.

    2017-04-01

    Radiobiological models of tumour control probability (TCP) can be personalized using imaging data. We propose an extension to a voxel-level radiobiological TCP model in order to describe patient-specific differences and intra-tumour heterogeneity. In the proposed model, tumour shrinkage is described by means of a novel kinetic Monte Carlo method for inter-voxel cell migration and tumour deformation. The model captures the spatiotemporal evolution of the tumour at the voxel level, and is designed to take imaging data as input. To test the performance of the model, three image-derived variables found to be predictive of outcome in the literature have been identified and calculated using the model’s own parameters. Simulating multiple tumours with different initial conditions makes it possible to perform an in silico study of the correlation of these variables with the dose for 50% tumour control (\\text{TC}{{\\text{D}}50} ) calculated by the model. We find that the three simulated variables correlate with the calculated \\text{TC}{{\\text{D}}50} . In addition, we find that different variables have different levels of sensitivity to the spatial distribution of hypoxia within the tumour, as well as to the dynamics of the migration mechanism. Finally, based on our results, we observe that an adequate combination of the variables may potentially result in higher predictive power.

  17. A model to describe potential effects of chemotherapy on critical radiobiological treatments

    Science.gov (United States)

    Rodríguez-Pérez, D.; Desco, M. M.; Antoranz, J. C.

    2016-08-01

    Although chemo- and radiotherapy can annihilate tumors on their own. they are also used in coadjuvancy: improving local effects of radiotherapy using chemotherapy as a radiosensit.izer. The effects of radiotherapy are well described by current radiobiological models. The goal of this work is to describe a discrete radiotherapy model, that has been previously used describe high radiation dose response as well as unusual radio-responses of some types of tumors (e.g. prostate cancer), to obtain a model of chemo+radiotherapy that can describe how the outcome of their combination is a more efficient removal of the tumor. Our hypothesis is that, although both treatments haven different mechanisms, both affect similar key points of cell metabolism and regulation, that lead to cellular death. Hence, we will consider a discrete model where chemotherapy may affect a fraction of the same targets destroyed by radiotherapy. Although radiotherapy reaches all cells equally, chemotherapy diffuses through a tumor attaining lower concentration in its center and higher in its surface. With our simulations we study the enhanced effect of combined therapy treatment and how it depends on the tissue critical parameters (the parameters of the lion-extensive radiobiological model), the number of “targets” aimed at by chemotherapy, and the concentration and diffusion rate of the drug inside the tumor. The results show that an equivalent, cliemo-radio-dose can be computed that allows the prediction of the lower radiation dose that causes the same effect than a radio-only treatment.

  18. Development of a soft X-ray microprobe for single cell radiobiology

    Institute of Scientific and Technical Information of China (English)

    CHEN Liang; YAN Jingwen; JIANG Shiping; YU Yang

    2009-01-01

    An X-ray microprobe for radiobiological studies was developed which deliver precise doses of radiation to the selected individual cells. The facility used synchrotron radiation as soft X-ray source. A zone plate combining with a pinhole produced a fine probe from bending magnet for single cell irradiating with defined doses. The diameter of microprobe at the target position was about 2 μm by scanning a knife-edge with an AXUV photo diode. The fluxes of soft X-rays at 516.7 eV (2.4 nm) were about 5.4×104 photons/s.100mA measured with the photo diode. The absorbed dose rate for typical yeast cells was about 11.34 Gy/s with the storage current of 100 mA. A preliminary experiment for yeast cells irradiation has shown that the microprobe had a definite biological effect for radiobiological investigations. The soft X-ray microprobe at "water window" region has provided a useful tool for single cell irradiating damage and a capability of individually irradiating a certain numbers of cells each time.

  19. Radiobiological characterization of post-lumpectomy focal brachytherapy with lipid nanoparticle-carried radionuclides

    Science.gov (United States)

    Hrycushko, Brian A.; Gutierrez, Alonso N.; Goins, Beth; Yan, Weiqiang; Phillips, William T.; Otto, Pamela M.; Bao, Ande

    2011-02-01

    Post-operative radiotherapy has commonly been used for early stage breast cancer to treat residual disease. The primary objective of this work was to characterize, through dosimetric and radiobiological modeling, a novel focal brachytherapy technique which uses direct intracavitary infusion of β-emitting radionuclides (186Re/188Re) carried by lipid nanoparticles (liposomes). Absorbed dose calculations were performed for a spherical lumpectomy cavity with a uniformly injected activity distribution using a dose point kernel convolution technique. Radiobiological indices were used to relate predicted therapy outcome and normal tissue complication of this technique with equivalent external beam radiotherapy treatment regimens. Modeled stromal damage was used as a measure of the inhibition of the stimulatory effect on tumor growth driven by the wound healing response. A sample treatment plan delivering 50 Gy at a therapeutic range of 2.0 mm for 186Re-liposomes and 5.0 mm for 188Re-liposomes takes advantage of the dose delivery characteristics of the β-emissions, providing significant EUD (58.2 Gy and 72.5 Gy for 186Re and 188Re, respectively) with a minimal NTCP (0.046%) of the healthy ipsilateral breast. Modeling of kidney BED and ipsilateral breast NTCP showed that large injected activity concentrations of both radionuclides could be safely administered without significant complications.

  20. Radiobiologically optimized couch shift: A new localization paradigm using cone-beam CT for prostate radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Yimei, E-mail: yhuang2@hfhs.org; Gardner, Stephen J.; Wen, Ning; Zhao, Bo; Gordon, James; Brown, Stephen; Chetty, Indrin J. [Department of Radiation Oncology, Henry Ford Health System, 2799 W Grand Boulevard, Detroit, Michigan 48202 (United States)

    2015-10-15

    Purpose: To present a novel positioning strategy which optimizes radiation delivery by utilizing radiobiological response knowledge and evaluate its use during prostate external beam radiotherapy. Methods: Five patients with low or intermediate risk prostate cancer were evaluated retrospectively in this IRB-approved study. For each patient, a VMAT plan with one 358° arc was generated on the planning CT (PCT) to deliver 78 Gy in 39 fractions. Five representative pretreatment cone beam CTs (CBCT) were selected for each patient. The CBCT images were registered to PCT by a human observer, which consisted of an initial automated registration with three degrees-of-freedom, followed by manual adjustment for agreement at the prostate/rectal wall interface. To determine the optimal treatment position for each CBCT, a search was performed centering on the observer-matched position (OM-position) utilizing a score function based on radiobiological and dosimetric indices (EUD{sub prostate}, D99{sub prostate}, NTCP{sub rectum}, and NTCP{sub bladder}) for the prostate, rectum, and bladder. We termed the optimal treatment position the radiobiologically optimized couch shift position (ROCS-position). Results: The dosimetric indices, averaged over the five patients’ treatment plans, were (mean ± SD) 79.5 ± 0.3 Gy (EUD{sub prostate}), 78.2 ± 0.4 Gy (D99{sub prostate}), 11.1% ± 2.7% (NTCP{sub rectum}), and 46.9% ± 7.6% (NTCP{sub bladder}). The corresponding values from CBCT at the OM-positions were 79.5 ± 0.6 Gy (EUD{sub prostate}), 77.8 ± 0.7 Gy (D99{sub prostate}), 12.1% ± 5.6% (NTCP{sub rectum}), and 51.6% ± 15.2% (NTCP{sub bladder}), respectively. In comparison, from CBCT at the ROCS-positions, the dosimetric indices were 79.5 ± 0.6 Gy (EUD{sub prostate}), 77.3 ± 0.6 Gy (D99{sub prostate}), 8.0% ± 3.3% (NTCP{sub rectum}), and 46.9% ± 15.7% (NTCP{sub bladder}). Excessive NTCP{sub rectum} was observed on Patient 5 (19.5% ± 6.6%) corresponding to localization at OM

  1. Dosimetric and radiobiologic comparison of 3D conformal versus intensity modulated planning techniques for prostate bed radiotherapy.

    Science.gov (United States)

    Koontz, Bridget F; Das, Shiva; Temple, Kathy; Bynum, Sigrun; Catalano, Suzanne; Koontz, Jason I; Montana, Gustavo S; Oleson, James R

    2009-01-01

    Adjuvant radiotherapy for locally advanced prostate cancer improves biochemical and clinical disease-free survival. While comparisons in intact prostate cancer show a benefit for intensity modulated radiation therapy (IMRT) over 3D conformal planning, this has not been studied for post-prostatectomy radiotherapy (RT). This study compares normal tissue and target dosimetry and radiobiological modeling of IMRT vs. 3D conformal planning in the postoperative setting. 3D conformal plans were designed for 15 patients who had been treated with IMRT planning for salvage post-prostatectomy RT. The same computed tomography (CT) and target/normal structure contours, as well as prescription dose, was used for both IMRT and 3D plans. Normal tissue complication probabilities (NTCPs) were calculated based on the dose given to the bladder and rectum by both plans. Dose-volume histogram and NTCP data were compared by paired t-test. Bladder and rectal sparing were improved with IMRT planning compared to 3D conformal planning. The volume of the bladder receiving at least 75% (V75) and 50% (V50) of the dose was significantly reduced by 28% and 17%, respectively (p = 0.002 and 0.037). Rectal dose was similarly reduced, V75 by 33% and V50 by 17% (p = 0.001 and 0.004). While there was no difference in the volume of rectum receiving at least 65 Gy (V65), IMRT planning significant reduced the volume receiving 40 Gy or more (V40, p = 0.009). Bladder V40 and V65 were not significantly different between planning modalities. Despite these dosimetric differences, there was no significant difference in the NTCP for either bladder or rectal injury. IMRT planning reduces the volume of bladder and rectum receiving high doses during post-prostatectomy RT. Because of relatively low doses given to the bladder and rectum, there was no statistically significant improvement in NTCP between the 3D conformal and IMRT plans.

  2. Radiological and Environmental Research Division, Center for Human Radiobiology. Annual report, July 1980-June 1981. [Lead abstract

    Energy Technology Data Exchange (ETDEWEB)

    1982-03-01

    Separate abstracts were prepared for the 22 papers of this annual report of the Center for Human Radiobiology. Abstracts were not written for 2 appendices which contain data on the exposure and radium-induced malignancies of 2259 persons whose radium content has been determined at least once. (KRM)

  3. Workshop Arboretum Volčji potok

    Directory of Open Access Journals (Sweden)

    Ana Kučan

    2012-01-01

    Full Text Available From its constitution onwards, the Volčji Potok Arboretum has been caught between various conflicting orientations. It is both a scientific, research and educational institution, and a cultural monument with exquisite garden and landscape design features and areas of great natural value and built cultural heritage, as well as commercial venue. At the same time, it functions as a park and an area for mass events, a garden centre and nursery. This variety of functions has helped Arboretum to survive the pressures of time; however, partial and uncoordinated interventions have threatened its original mission and its image and generated a number of conflicting situations. The workshop, organised on the initiative of the Institute for the Protection of Cultural Heritage of Slovenia, which involved students from the Faculty of Architecture and students from the Department of Landscape Architecture of the Biotechnical Faculty in mixed groups, generated eight proposals to solve some of the most urgent problems by introducing optimised development with clearly defined goals and priorities.

  4. Comparison of Different Fractionation Schedules Toward a Single Fraction in High-Dose-Rate Brachytherapy as Monotherapy for Low-Risk Prostate Cancer Using 3-Dimensional Radiobiological Models

    Energy Technology Data Exchange (ETDEWEB)

    Mavroidis, Panayiotis, E-mail: mavroidis@uthscsa.edu [Department of Radiation Oncology, University of Texas Health Sciences Center, San Antonio, Texas (United States); Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm (Sweden); Milickovic, Natasa [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach GmbH, Offenbach (Germany); Cruz, Wilbert F. [Department of Radiation Oncology, University of Texas Health Sciences Center, San Antonio, Texas (United States); Tselis, Nikolaos [Strahlenklinik, Klinikum Offenbach GmbH, Offenbach (Germany); Karabis, Andreas [Pi-Medical Ltd., Athens (Greece); Stathakis, Sotirios; Papanikolaou, Nikos [Department of Radiation Oncology, University of Texas Health Sciences Center, San Antonio, Texas (United States); Zamboglou, Nikolaos [Strahlenklinik, Klinikum Offenbach GmbH, Offenbach (Germany); Baltas, Dimos [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach GmbH, Offenbach (Germany); Nuclear and Particle Physics Section, Physics Department, University of Athens, Athens (Greece)

    2014-01-01

    Purpose: The aim of the present study was the investigation of different fractionation schemes to estimate their clinical impact. For this purpose, widely applied radiobiological models and dosimetric measures were used to associate their results with clinical findings. Methods and Materials: The dose distributions of 12 clinical high-dose-rate brachytherapy implants for prostate were evaluated in relation to different fractionation schemes. The fractionation schemes compared were: (1) 1 fraction of 20 Gy; (2) 2 fractions of 14 Gy; (3) 3 fractions of 11 Gy; and (4) 4 fractions of 9.5 Gy. The clinical effectiveness of the different fractionation schemes was estimated through the complication-free tumor control probability (P{sub +}), the biologically effective uniform dose, and the generalized equivalent uniform dose index. Results: For the different fractionation schemes, the tumor control probabilities were 98.5% in 1 × 20 Gy, 98.6% in 2 × 14 Gy, 97.5% in 3 × 11 Gy, and 97.8% in 4 × 9.5 Gy. The corresponding P{sub +} values were 88.8% in 1 × 20 Gy, 83.9% in 2 × 14 Gy, 86.0% in 3 × 11 Gy, and 82.3% in 4 × 9.5 Gy. With use of the fractionation scheme 4 × 9.5 Gy as reference, the isoeffective schemes regarding tumor control for 1, 2, and 3 fractions were 1 × 19.68 Gy, 2 × 13.75 Gy, and 3 × 11.05 Gy. The optimum fractionation schemes for 1, 2, 3, and 4 fractions were 1 × 19.16 Gy with a P{sub +} of 91.8%, 2 × 13.2 Gy with a P{sub +} of 89.6%, 3 × 10.6 Gy with a P{sub +} of 88.4%, and 4 × 9.02 Gy with a P{sub +} of 86.9%. Conclusions: Among the fractionation schemes 1 × 20 Gy, 2 × 14 Gy, 3 × 11 Gy, and 4 × 9.5 Gy, the first scheme was more effective in terms of P{sub +}. After performance of a radiobiological optimization, it was shown that a single fraction of 19.2 to 19.7 Gy (average 19.5 Gy) should produce at least the same benefit as that given by the 4 × 9.5 Gy scheme, and it should reduce the expected total complication probability by

  5. Hadron Radiobiology : Investigation of the Inhibition of ten days Growth of Vicia Faba Roots after Exposure in the 600 MeV Neutron Beam from SC2 Hadron Radiobiology : Investigation of the Inhibition of ten days'Grown of Vicia Faba Roots after Exposure in the 600 MeV Neutron Beam from SC2

    CERN Multimedia

    2002-01-01

    Hadron Radiobiology : Investigation of the Inhibition of ten days Growth of Vicia Faba Roots after Exposure in the 600 MeV Neutron Beam from SC2 Hadron Radiobiology : Investigation of the Inhibition of ten days'Grown of Vicia Faba Roots after Exposure in the 600 MeV Neutron Beam from SC2

  6. Modification of radiobiological effects of 171 MeV protons by elements of physical protection

    Science.gov (United States)

    Bulinina, Taisia; Shurshakov, Vyacheslav; Ivanov, Alexander; Molokanov, Alexander

    2016-07-01

    Space radiation includes protons of various energies. Physical protection is effective in the case of low energy protons (50-100 MeV) and becomes insufficient for radiation with a high part of high-energy protons. In the experiment performed on outbred mice, the purpose of the study was to evaluate the radiobiological effect of 171 MeV protons and protons modified by elements of physical protection of the spacecraft, on a complex of indicators of the functional condition of the system hematopoiesis and the central nervous system in 24 hours after irradiation at 20 cGy dose. The spacecraft radiation protection elements used in the experiment were a construction of wet hygiene wipes called a «protective curtain», and a glass plate imitating an ISS window. Mass thickness of the " protective curtain" in terms of water equivalent was ̴ 6,2 g/cm2. Physical shielding along the path of 171 MeV protons increases their linear energy transfer leading to the absorbed dose elevation and strengthening of the radiobiological effect. In the experiment, the two types of shielding together raised the absorbed dose from 20 to 23.2 cGy. Chemically different materials (glass and water in the wipes) were found to exert unequal modifying effects on physical and biological parameters of the proton-irradiated mice. There was a distinct dose-dependent reduction of bone marrow cellularity within the dose range from 20 cGy to 23.2 cGy in 24 hours after exposure. No modifying effect of the radiation protection elements on spontaneous motor activity was discovered when compared with entrance protons. The group of animals protected by the glass plate exhibited normal orientative-trying reactions and weakened grip with the forelimbs. The effects observed in the experiment indicate the necessity to carry out comprehensive radiobiological researches (physical, biological and mathematical) in assessing the effects of physical protection, that are actual for ensuring radiation safety of crews in

  7. Heavy charged particle radiobiology: using enhanced biological effectiveness and improved beam focusing to advance cancer therapy.

    Science.gov (United States)

    Allen, Christopher; Borak, Thomas B; Tsujii, Hirohiko; Nickoloff, Jac A

    2011-06-03

    Ionizing radiation causes many types of DNA damage, including base damage and single- and double-strand breaks. Photons, including X-rays and γ-rays, are the most widely used type of ionizing radiation in radiobiology experiments, and in radiation cancer therapy. Charged particles, including protons and carbon ions, are seeing increased use as an alternative therapeutic modality. Although the facilities needed to produce high energy charged particle beams are more costly than photon facilities, particle therapy has shown improved cancer survival rates, reflecting more highly focused dose distributions and more severe DNA damage to tumor cells. Despite early successes of charged particle radiotherapy, there is room for further improvement, and much remains to be learned about normal and cancer cell responses to charged particle radiation.

  8. AFRRI (Armed Forces Radiobiology Research Institute) reports, July, August and September 1986. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    1986-01-01

    Contents include: post-radiation regional cerebral blood flow in primates; heart-function studies in dogs after acute gamma irradiation of the precordium; the effect of anesthetic, sedative or narcotic drugs on intrahepatic and extrahepatic biliary kinetics; effect of gamma radiation on sodium channels in different conformations in neuroblastoma cells; effects of ethanol exposure on brain sodium channels; ionizing radiation alters the properties of sodium channels in rat brain synaptosomes; thymic hormones in thymus recovery from radiation injury; acute toxicity of petroleum- and shale-derived distillate fuel; light microscopic, hematologic, and serum chemistry studies; radioprotective properties of detoxified lipid A from Salmonella Minnesota R595; brain areas involved in production of morphine-induced locomotor hyperactivity of the C57B1/6J mouse; preliminary evaluation of US Army radiac detector DT-236/PD and radiac computer-indicator CP-696/UD; and calorimetric dose measurements and calorimetric system developed for the armed forces radiobiology research institute.

  9. Radiobiological studies with the nematode Caenorhabditis elegans. Genetic and developmental effects of high LET radiation

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, G.A.; Schubert, W.W.; Marshall, T.M. (Jet Propulsion Lab., Pasadena, CA (United States))

    1992-01-01

    The biological effects of heavy charged particle (HZE) radiation are of particular interest to travellers and planners for long-duration space flights where exposure levels represents a potential health hazard. The unique feature of HZE radiation is the structured pattern of its energy deposition in targets. There are many consequences of this feature to biological endpoints when compared with effects of ionizing photons. Dose vs response and dose-rate kinetics may be modified, DNA and cellular repair systems may be altered in their abilities to cope with damage, and the qualitative features of damage may be unique for different ions. The nematode Caenorhabditis elegans is being used to address these and related questions associated with exposure to radiation. HZE-induced mutation, chromosome aberration, cell inactivation and altered organogenesis are discussed along with plans for radiobiological experiments in space. (author).

  10. Radiobiological studies with the nematode Caenorhabditis elegans. Genetic and developmental effects of high LET radiation

    Science.gov (United States)

    Nelson, G. A.; Schubert, W. W.; Marshall, T. M.

    1992-01-01

    The biological effects of heavy charged particle (HZE) radiation are of particular interest to travellers and planners for long-duration space flights where exposure levels represent a potential health hazard. The unique feature of HZE radiation is the structured pattern of its energy deposition in targets. There are many consequences of this feature to biological endpoints when compared with effects of ionizing photons. Dose vs response and dose-rate kinetics may be modified, DNA and cellular repair systems may be altered in their abilities to cope with damage, and the qualitative features of damage may be unique for different ions. The nematode Caenorhabditis elegans is being used to address these and related questions associated with exposure to radiation. HZE-induced mutation, chromosome aberration, cell inactivation and altered organogenesis are discussed along with plans for radiobiological experiments in space.

  11. Jolivet: Complete Flute Music, Vol. 2 / Guy S. Rickards

    Index Scriptorium Estoniae

    Rickards, Guy S.

    1996-01-01

    Uuest heliplaadist "Jolivet: Complete Flute Music, Vol. 2. Kroumata Percussion Ensemble, Tapiola Sinfonietta, Paavo Järvi". BIS CD 739 (64 minutes: DDD). Item marked from CD630 (6/94), CD272, remainder new to UK

  12. The radiobiological principles of boron neutron capture therapy: A critical review

    Energy Technology Data Exchange (ETDEWEB)

    Hopewell, J.W., E-mail: john.hopewell@gtc.ox.ac.uk [Green Templeton College and Particle Therapy Cancer Research Institute, University of Oxford, Oxford (United Kingdom); Morris, G.M. [Medical Department, Brookhaven National Laboratory, Upton, NY (United States); Schwint, A. [Department of Radiobiology, Constituyentes Atomic Center, National Atomic Energy Commission, San Martin, Buenos Aires (Argentina); Coderre, J.A. [Ora Inc, 300 Brickstone Square, Andover, MA (United States)

    2011-12-15

    The radiobiology of the dose components in a BNCT exposure is examined. The effect of exposure time in determining the biological effectiveness of {gamma}-rays, due to the repair of sublethal damage, has been largely overlooked in the application of BNCT. Recoil protons from fast neutrons vary in their relative biological effectiveness (RBE) as a function of energy and tissue endpoint. Thus the energy spectrum of a beam will influence the RBE of this dose component. Protons from the neutron capture reaction in nitrogen have not been studied but in practice protons from nitrogen capture have been combined with the recoil proton contribution into a total proton dose. The relative biological effectiveness of the products of the neutron capture reaction in boron is derived from two factors, the RBE of the short range particles and the bio-distribution of boron, referred to collectively as the compound biological effectiveness factor. Caution is needed in the application of these factors for different normal tissues and tumors. - Highlights: Black-Right-Pointing-Pointer Radiobiological properties of different dose components in BNCT are considered. Black-Right-Pointing-Pointer Effectiveness of {gamma}-ray dose depends strongly on exposure time due to sublethal damage repair. Black-Right-Pointing-Pointer Effectiveness of fast neutron dose depends on neutron energy spectrum. Black-Right-Pointing-Pointer {gamma}-ray and fast neutron characteristics vary between beams and thus weighting factors will differ. Black-Right-Pointing-Pointer Weighing factors for boron dose depend on the carrier, the tissue and its mode of administration.

  13. A semi-analytical radiobiological model may assist treatment planning in light ion radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kundrat, Pavel [Institute of Physics, Academy of Sciences of the Czech Republic, Na Slovance 2, CZ-182 21 Prague 8 (Czech Republic)

    2007-12-07

    A semi-analytical model of light ions' Bragg peaks is presented and used in conjunction with a detailed probabilistic radiobiological module to predict the biological effectiveness of light ion irradiation for hadrontherapy applications. The physical Bragg peak model is based on energy-loss calculations with the SRIM code and phenomenological formulae for the energy-loss straggling. Effects of nuclear reactions are accounted for on the level of reducing the number of primary particles only. Reaction products are not followed at all and their contribution to dose deposition is neglected. Beam widening due to multiple scattering and calculations of spread-out Bragg peaks are briefly discussed. With this simple physical model, integral depth-dose distributions are calculated for protons, carbon, oxygen and neon ions. A good agreement with published experimental data is observed for protons and lower energy ions (with ranges in water up to approximately 15 cm), while less satisfactory results are obtained for higher energy ions due to the increased role of nuclear reaction products, neglected in this model. A detailed probabilistic radiobiological module is used to complement the simple physical model and to estimate biological effectiveness along the penetration depth of Bragg peak irradiation. Excellent agreement is found between model predictions and experimental data for carbon beams, indicating potential applications of the present scheme in treatment planning in light ion hadrontherapy. Due to the semi-analytical character of the model, leading to high computational speed, applications are foreseen in particular in the fully biological optimization of multiple irradiation fields and intensity-modulated beams.

  14. A semi-analytical radiobiological model may assist treatment planning in light ion radiotherapy.

    Science.gov (United States)

    Kundrát, Pavel

    2007-12-07

    A semi-analytical model of light ions' Bragg peaks is presented and used in conjunction with a detailed probabilistic radiobiological module to predict the biological effectiveness of light ion irradiation for hadrontherapy applications. The physical Bragg peak model is based on energy-loss calculations with the SRIM code and phenomenological formulae for the energy-loss straggling. Effects of nuclear reactions are accounted for on the level of reducing the number of primary particles only. Reaction products are not followed at all and their contribution to dose deposition is neglected. Beam widening due to multiple scattering and calculations of spread-out Bragg peaks are briefly discussed. With this simple physical model, integral depth-dose distributions are calculated for protons, carbon, oxygen and neon ions. A good agreement with published experimental data is observed for protons and lower energy ions (with ranges in water up to approximately 15 cm), while less satisfactory results are obtained for higher energy ions due to the increased role of nuclear reaction products, neglected in this model. A detailed probabilistic radiobiological module is used to complement the simple physical model and to estimate biological effectiveness along the penetration depth of Bragg peak irradiation. Excellent agreement is found between model predictions and experimental data for carbon beams, indicating potential applications of the present scheme in treatment planning in light ion hadrontherapy. Due to the semi-analytical character of the model, leading to high computational speed, applications are foreseen in particular in the fully biological optimization of multiple irradiation fields and intensity-modulated beams.

  15. Transnational science and collaborative networks. The case of Genetics and Radiobiology in Mexico, 1950-1970.

    Science.gov (United States)

    Barahona, Ana

    2015-01-01

    The transnational approach of the science and technology studies (S&TS) abandons the nation as a unit of analysis in order to understand the development of science history. It also abandons Euro-US-centred narratives in order to explain the role of international collaborative networks and the circulation of knowledge, people, artefacts and scientific practices. It is precisely under this perspective that the development of genetics and radiobiology in Mexico shall be analyzed, together with the pioneering work of the Mexican physician-turned-geneticist Alfonso León de Garay who spent two years in the Galton Laboratory in London under the supervision of Lionel Penrose. Upon his return de Garay funded the Genetics and Radiobiology Program of the National Commission of Nuclear Energy based on local needs and the aim of working beyond geographical limitations to thus facilitate the circulation of knowledge, practices and people. The three main lines of research conducted in the years after its foundation that were in line with international projects while responding to the national context were, first, cytogenetic studies of certain abnormalities, and the cytogenetics and anthropological studies of the Olympic Games held in Mexico in 1968; second, the study of the effects of radiation on hereditary material; and third, the study of population genetics in Drosophila and in Mexican indigenous groups. The program played a key role in reshaping the scientific careers of Mexican geneticists, and in transferring locally sourced research into broader networks. This case shows the importance of international collaborative networks and circulation in the constitution of national scientific elites, and also shows the national and transnational concerns that shaped local practices.

  16. Chasing Ghosts in Space Radiobiology Research: The Lost Focus on Non-Targeted Effects

    Science.gov (United States)

    Cucinotta, Francis; Saganti, Premkumar; Cacao, Eliedonna

    2016-07-01

    The doses and dose-rates of astronaut exposures to galactic cosmic rays (GCR) are accurately known, and lead to particle hits per cell nucleus from high charge and energy (HZE) particles of much less than one hit per cell per week. A large number of experiments have shown that additivity of biological effects is a valid assumption for space radiation exposures, while experiments at higher doses and dose-rates than occur in space continue to be a focus of the majority of space radiobiology research. Furthermore HZE particle exposures with mono-energetic particles manifest themselves as a mixed-radiation field due to the contributions of delta-rays and the random impact parameter of a particles track core to DNA and non-DNA targets in cells and tissues. The mixed-field manifestation of mono-energetic HZE particle exposures is well known from theoretical studies of microdosimetry and track structure. Additional mixed-field effects occur for single species experiments due to nuclear fragmentation in particle accelerator beam-lines and biological samples along with energy straggling. In contrast to these well known aspects of space radiobiology there are many open questions on the contribution of non-targeted effects to low dose and dose-rate exposures. Non-targeted effects (NTEs) include bystander effects and genomic instability, and have been shown to be the most important outstanding question for reducing uncertainties in space radiation cancer risk assessment. The dose-rate and radiation quality dependence of NTE's has not been established, while there is an over-arching need to develop 21st century experimental models of human cancer risk. We review possible mechanisms of NTE's and how new experiments to address these issues could be designed.

  17. Light ions radiobiological effects on human tumoral cells: measurements modelling and application to hadron-therapy; Mesures et modelisation des effets radiobiologiques des ions legers sur des cellules tumorales humaines: application a l'hadrontherapie

    Energy Technology Data Exchange (ETDEWEB)

    Jalade, P

    2005-11-15

    In classical radiotherapy, the characteristics of photons interactions undergo limits for the treatment of radioresistant and not well located tumours. Pioneering treatments of patients at the Lawrence Laboratory at Berkeley has demonstrated two advantages of hadrons beams: the Relative Biologic Effect (the RBE) and the ballistic of the beams. Since 1994, the clinical centre at Chiba, has demonstrated successfully the applicability of the method. A physics group, managed by G. Kraft, at Darmstadt in Germany, has underlined the advantages of carbon beams. An European pool, called ENGIGHT (European Network for LIGHt ion Therapy) has been created in which the French ETOILE project appeared. The purpose of the thesis concerns measurements and models of 'in vitro' human cells survival. In the first part, the nowadays situation in particles interactions, tracks and cells structures and radiobiology is presented here. The second is devoted to the models based on the beam tracks and localization of the physical dose. Discussion of sensitivity to various parameters of the model has been realized with the help of numerical simulations. Finally the predictions of the improved model has been compared to experimental irradiations of human cells with argon and carbon beams of the GANIL machine. Conclusion of such study shows the performance and limits of a local model for predicting the radiobiological efficiency of light ions in hadron-therapy. (author)

  18. Professor Hassan K. Awwad; The Father of Radiation Oncology and Radiobiology in Egypt and the Arab World, His Good Deeds Last Forever and Inspire us for the Future.

    Science.gov (United States)

    Zaghloul, Mohamed S; El-Badawi, Samy A; Abd Elbaky, Hoda

    2007-03-01

    , Libya, Palastine, Iraq, Uganda, Nigeria and other countries. He himself had many teaching missions in different Arab countries (Saudi Arabia, Kuwait and others) for the sake of groups of his students that could not come to Egypt. He served as the head of the Department of Radiation Oncology for more than 15 years (1970-1985), full time Professor in Radiation Oncology and Radiobiology (1985-2007), Professor of Radiotherapy, Alexandria University (1954-1970), Chief of the Department of Nuclear Medicine, Medical Research Institute, University of Alexandria (1963-1964), Chief of the Radiotherapy Unit in the Heliopolis Hospital, Ministry of Public Health, 1985-2007. He was co-founder of the Egyptian Society of Cancer and acted as vice present and head of the scientific committee of the society. He shared the activities of many Egyptian, Arab and international scientific societies. His activities in these societies were great. Prof. Awwad had direct contact with his students that never ended, even after some of them left to work in other places in USA, Canada, Europe or Arab Countries. His students' specialty varied between radiobiology, pharmacology, biochemistry, tumor biology, radiation oncology, medical oncology and surgical oncology. Prof. Awwad had more than 100 published articles on hypoxia and hypoxic cell radiosensitizers, biology of growth of human tumors, biology and clinical models of the time factor in external beam radiotherapy, biology and mathematical models of time factor in brachytherapy, radioactive dynamic cancer studies of plasma protein metabolism, radioactive dynamic factor studies of blood disorders and lymphoma, radiation damage of DNA and normal tissues,head and neck cancer, bladder cancer, breast cancer, cervical cancer and development and optimization of clinical radiotherapy. He had continuous cooperation and collaboration with many of the great scientists and clinicians in Holland, France, United Kingdom, USA and Japan. He continued to exchange

  19. Optimization in brachytherapy with the implementation of Radiobiology; Optimizacion en Braquiterapia con la implementacion de la Radiobiologia

    Energy Technology Data Exchange (ETDEWEB)

    Duran, M.P.; Bourel, V.J.; Rodriguez, I.; Torre, M. de la; Caneva, S. [Braqui S.R.L. Viamonte 1861, Buenos Aires (Argentina)

    1998-12-31

    In the brachytherapy planning treatments with High dose rates (HDR), the optimization algorithms used are based in dosimetric considerations and/or geometric ones, ignoring the radiobiological response of the tissue treated. In this work we wish to show the implementation of radiobiological concepts in the optimization. Assuming that the subtiles differences that result in the dose distribution among the different optimization models which are not visible in an isodose plane, it is studied how is classically make it , the quality implant through natural histograms about dose volumes and the resulting parameters. Also is studied the necrosis probability which may be caused by the choice of some optimization model, allowing with this the choice of the best implant. (Author)

  20. Comp Plan: A computer program to generate dose and radiobiological metrics from dose-volume histogram files.

    Science.gov (United States)

    Holloway, Lois Charlotte; Miller, Julie-Anne; Kumar, Shivani; Whelan, Brendan M; Vinod, Shalini K

    2012-01-01

    Treatment planning studies often require the calculation of a large number of dose and radiobiological metrics. To streamline these calculations, a computer program called Comp Plan was developed using MATLAB. Comp Plan calculates common metrics, including equivalent uniform dose, tumor control probability, and normal tissue complication probability from dose-volume histogram data. The dose and radiobiological metrics can be calculated for the original data or for an adjusted fraction size using the linear quadratic model. A homogeneous boost dose can be added to a given structure if desired. The final output is written to an Excel file in a format convenient for further statistical analysis. Comp Plan was verified by independent calculations. A lung treatment planning study comparing 45 plans for 7 structures using up to 6 metrics for each structure was successfully analyzed within approximately 5 minutes with Comp Plan. The code is freely available from the authors on request.

  1. Radiobiology for eye plaque brachytherapy and evaluation of implant duration and radionuclide choice using an objective function

    Energy Technology Data Exchange (ETDEWEB)

    Gagne, Nolan L.; Leonard, Kara L.; Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States)

    2012-06-15

    Purpose: Clinical optimization of Collaborative Ocular Melanoma Study (COMS) eye plaque brachytherapy is currently limited to tumor coverage, consensus prescription dosage, and dose calculations to ocular structures. The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide R and implant duration T. This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position P, prescription dose, R, and T. Methods: Plaque-heterogeneity-corrected dose distributions were generated with MCNP5 for the range of currently available COMS plaques loaded with sources using three available low-energy radionuclides. These physical dose distributions were imported into the PINNACLE{sup 3} treatment planning system using the TG-43 hybrid technique and used to generate dose volume histograms for a T = 7 day implant within a reference eye geometry including the ciliary body, cornea, eyelid, foveola, lacrimal gland, lens, optic disc, optic nerve, retina, and tumor at eight standard treatment positions. The equation of Dale and Jones was employed to create biologically effective dose volume histograms (BEDVHs), allowing for BED volumetric analysis of all ROIs. Isobiologically effective prescription doses were calculated for T = 5 days down to 0.01 days, with BEDVHs subsequently generated for all ROIs using correspondingly reduced prescription doses. Objective functions were created to evaluate the BEDVHs as a function of R and T. These objective functions are mathematically accessible and sufficiently general to be applied to temporary or permanent brachytherapy implants for a variety of disease sites. Results: Reducing T from 7 to 0.01 days for a 10 mm plaque produced an average BED benefit of 26%, 20%, and 17% for {sup 103}Pd, {sup 125}I, and {sup 131}Cs, respectively, for all P; 16 and 22 mm plaque results were more position-dependent. {sup 103}Pd produced a 16

  2. Spinal cord response to altered fractionation and re-irradiation: Radiobiological considerations and role of bioeffect models

    Directory of Open Access Journals (Sweden)

    Supe Sanjay

    2006-01-01

    Full Text Available The aim of radiation oncologist is to implement an uncomplicated loco regional control of cancer by radiation therapy. The bioeffect of a physical dose depends on the nature of the tissue, fractionation scheme, dose rate and treatment time. The transformation of absorbed dose into a bioeffect dose is controlled by treatment variables and the radiobiological characteristics of the relevant tissue. Various bioeffect models have been proposed to predict the biological effect of radiotherapy treatments. Dale has proposed extrapolated response dose (ERD equations for external beam therapy, intracavitary brachytherapy and interstitial brachytherapy. Within the context of the LQ model, the parameter which quantifies the overall biological effect on a given tissue is the biologically effective dose (BED which is obtained by applying repopulation correction to ERD (Orton,. Thames proposed the total effect (TE concept based on the incomplete repair LQ model which accounts for the biological effect of a fractionated course of radiotherapy. Spinal cord myelitis limits the dose to tumours in the head and neck, thoracic and upper abdominal regions resulting in reduction of tumour control probability. Radiation myelopathy is one of the most devastating complications of clinical radiotherapy. Treatment techniques that are designed to minimize the risk of spinal cord injury are likely to underdose the tumour consequent failure to control the disease. Since radiation myelopathy results in severe and irreversible morbidity, it is important to establish the tolerance dose of the spinal cord. A number of patients have recently been reported to have developed radiation myelopathy following hyperfractionated accelerated radiotherapy. As the survival rates of patients increase, radiation oncologists are more frequently faced with the problem of treatment of late recurrence or second tumours situated within or close to previously treated site. A rationale for taking a

  3. Radioembolisation with {sup 90}Y-microspheres: dosimetric and radiobiological investigation for multi-cycle treatment

    Energy Technology Data Exchange (ETDEWEB)

    Cremonesi, Marta; Ferrari, Mahila; Pedroli, Guido [European Institute of Oncology, Unit of Medical Physics, Milan (Italy); Bartolomei, Mirco; Arico, Demetrio; De Cicco, Concetta [European Institute of Oncology, Division of Nuclear Medicine, Milan (Italy); Orsi, Franco; Bonomo, Guido [European Institute of Oncology, Unit of Interventistic Radiology, Milan (Italy); Mallia, Andrew [Gamma Unit, Radiology Department, St. Luke' s Hospital (Malta); Paganelli, Giovanni [European Institute of Oncology, Division of Nuclear Medicine, Milan (Italy)

    2008-11-15

    Radioembolisation with {sup 90}Y-microspheres is a new locoregional treatment of hepatic lesions, usually applied as single cycle. Multi-cycle treatments might be considered as a strategy to improve the risk-benefit balance. With the aim to derive suitable information for patient tailored therapy, available patients' dosimetric data were reviewed according to the linear-quadratic model and converted into biological effective dose (BED) values. Single vs. multi-cycle approaches were compared through radiobiological perspective. Twenty patients with metastatic lesions underwent radioembolisation. The {sup 90}Y-administered activity (AA) was established in order to respect a precautionary limit dose (40 Gy) for the non-tumoral liver (NTL). BED was calculated setting {alpha}/{beta} = 2.5 Gy (NTL), 10 Gy (tumours); T{sub 1/2,eff} = T{sub 1/2,phys} = 64.2 h; T{sub 1/2,rep} = 2.5 h (NTL), 1.5 h (tumours). The BED to NTL was considered as a constraint for multi-cycle approach. The AA for two cycles and the percent variations of AA, tumour dose, BED were estimated. In one-cycle, for a prescribed BED to NTL of 64 Gy (NTL dose = 40 Gy), AA was 1.7 (0.9-3.2) GBq, tumour dose was 130 (65-235) Gy, and tumour BED was 170 (75-360) Gy. Considering two cycles, {proportional_to}15% increase was found for AA and dose to NTL, with unvaried BED for NTL. Tumour dose increase was 20 (10-35) Gy; tumour BED increase was 10 (3-11) Gy. In different protocols allowing 80 Gy to NTL, the BED sparing estimated was {proportional_to}50 Gy (two cycles) and 65 Gy (three cycles). From a radiobiological perspective, multi-cycle treatments would allow administering higher activities with increased tumour irradiation and preserved radiation effects on NTL. Trials comparing single vs. multiple cycles are suggested. (orig.)

  4. Light ion production for a future radiobiological facility at CERN: preliminary studies.

    Science.gov (United States)

    Stafford-Haworth, Joshua; Bellodi, Giulia; Küchler, Detlef; Lombardi, Alessandra; Röhrich, Jörg; Scrivens, Richard

    2014-02-01

    Recent medical applications of ions such as carbon and helium have proved extremely effective for the treatment of human patients. However, before now a comprehensive study of the effects of different light ions on organic targets has not been completed. There is a strong desire for a dedicated facility which can produce ions in the range of protons to neon in order to perform this study. This paper will present the proposal and preliminary investigations into the production of light ions, and the development of a radiobiological research facility at CERN. The aims of this project will be presented along with the modifications required to the existing linear accelerator (Linac3), and the foreseen facility, including the requirements for an ion source in terms of some of the specification parameters and the flexibility of operation for different ion types. Preliminary results from beam transport simulations will be presented, in addition to some planned tests required to produce some of the required light ions (lithium, boron) to be conducted in collaboration with the Helmholtz-Zentrum für Materialien und Energie, Berlin.

  5. Radiobiology and Reproduction—What Can We Learn from Mammalian Females?

    Directory of Open Access Journals (Sweden)

    Montserrat Garcia-Caldés

    2012-08-01

    Full Text Available Ionizing radiation damages DNA and induces mutations as well as chromosomal reorganizations. Although radiotherapy increases survival among cancer patients, this treatment does not come without secondary effects, among which the most problematic is gonadal dysfunction, especially in women. Even more, if radio-induced DNA damage occurs in germ cells during spermatogenesis and/or oogenesis, they can produce chromosomal reorganizations associated with meiosis malfunction, abortions, as well as hereditary effects. However, most of our current knowledge of ionizing radiation genotoxic effects is derived from in vitro studies performed in somatic cells and there are only some experimental data that shed light on how germ cells work when affected by DNA alterations produced by ionizing radiation. In addition, these few data are often related to mammalian males, making it difficult to extrapolate the results to females. Here, we review the current knowledge of radiobiology and reproduction, paying attention to mammalian females. In order to do that, we will navigate across the female meiotic/reproductive cycle/life taking into account the radiation-induced genotoxic effects analysis and animal models used, published in recent decades.

  6. Radiobiological inactivation of Epstein-Barr virus. [UV and X radiation

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, E.; Heston, L.; Grogan, E.; Miller, G.

    1978-01-01

    Lymphocyte transforming properties of B95-8 strain Epstein-Barr virus (EBV) are very sensitive to inactivation by either uv or x irradiation. No dose of irradiation increases the transforming capacity of EBV. The x-ray dose needed for inactivation of EBV transformation (dose that results in 37% survival, 60,000 rads) is similar to the dose required for inactivation of plaque formation by herpes simplex virus type 1 (Fischer strain). Although herpes simplex virus is more sensitive than EBV to uv irradiation, this difference is most likely due to differences in the kinetics or mechanisms of repair of uv damage to the two viruses. The results lead to the hypothesis that a large part, or perhaps all, of the EBV genome is in some way needed to initiate transformation. The abilities of EBV to stimulate host cell DNA synthesis, to induce nuclear antigen, and to immortalize are inactivated in parallel. All clones of marmoset cells transformed by irradiated virus produce extracellular transforming virus. These findings suggest that the abilities of the virus to transform and to replicate complete progeny are inactivated together. The amounts of uv and x irradiation that inactivate transformation by B95-8 virus are less than the dose needed to inactivate early antigen induction by the nontransforming P/sub 3/HR-1 strain of EBV. Based on radiobiological inactivation, 10 to 50% of the genome is needed for early antigen induction.

  7. Radiobiology of Small Hive Beetle (Coleoptera: Nitidulidae) and Prospects for Management Using Sterile Insect Releases.

    Science.gov (United States)

    Downey, Danielle; Chun, Stacey; Follett, Peter

    2015-06-01

    Small hive beetle, Aethina tumida Murray (Coleoptera: Nitidulidae), is considered a serious threat to beekeeping in the Western Hemisphere, Australia, and Europe mainly due to larval feeding on honey, pollen, and brood of the European honeybee, Apis mellifera L. Control methods are limited for this pest. Studies were conducted to provide information on the radiobiology of small hive beetle and determine the potential for sterile insect releases as a control strategy. Adult males and females were equally sensitive to a radiation dose of 80 Gy and died within 5-7 d after treatment. In reciprocal crossing studies, irradiation of females only lowered reproduction to a greater extent than irradiation of males only. For matings between unirradiated males and irradiated females, mean reproduction was reduced by >99% at 45 and 60 Gy compared with controls, and no larvae were produced at 75 Gy. Irradiation of prereproductive adults of both sexes at 45 Gy under low oxygen (1-4%) caused a high level of sterility (>99%) while maintaining moderate survivorship for several weeks, and should suffice for sterile insect releases. Sterile insect technique holds potential for suppressing small hive beetle populations in newly invaded areas and limiting its spread.

  8. Radiograaff, a proton irradiation facility for radiobiological studies at a 4 MV Van de Graaff accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Constanzo, J. [Université de Lyon, F-69622, Lyon (France); Université Lyon 1, Villeurbanne (France); CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, F-69622 Villeurbanne (France); Fallavier, M., E-mail: m.fallavier@ipnl.in2p3.fr [Université de Lyon, F-69622, Lyon (France); Université Lyon 1, Villeurbanne (France); CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, F-69622 Villeurbanne (France); Alphonse, G. [Université de Lyon, F-69622, Lyon (France); Université Lyon 1, Villeurbanne (France); Faculté de Médecine Lyon-Sud, LRCM, F-69921 Oullins (France); Hospices-Civils-de-Lyon, CHLS, F-69495 Pierre-Bénite (France); Bernard, C. [Université de Lyon, F-69622, Lyon (France); Université Lyon 1, Villeurbanne (France); CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, F-69622 Villeurbanne (France); Battiston-Montagne, P. [Université de Lyon, F-69622, Lyon (France); Université Lyon 1, Villeurbanne (France); Faculté de Médecine Lyon-Sud, LRCM, F-69921 Oullins (France); Rodriguez-Lafrasse, C. [Université de Lyon, F-69622, Lyon (France); Université Lyon 1, Villeurbanne (France); Faculté de Médecine Lyon-Sud, LRCM, F-69921 Oullins (France); Hospices-Civils-de-Lyon, CHLS, F-69495 Pierre-Bénite (France); and others

    2014-09-01

    A horizontal beam facility for radiobiological experiments with low-energy protons has been set up at the 4 MV Van de Graaff accelerator of the Institut de Physique Nucléaire de Lyon. A homogeneous irradiation field with a suitable proton flux is obtained by means of two collimators and two Au-scattering foils. A monitoring chamber contains a movable Faraday cup, a movable quartz beam viewer for controlling the intensity and the position of the initial incident beam and four scintillating fibers for beam monitoring during the irradiation of the cell samples. The beam line is ended by a thin aluminized Mylar window (12 μm thick) for the beam extraction in air. The set-up was simulated by the GATE v6.1 Monte-Carlo platform. The measurement of the proton energy distribution, the evaluation of the fluence-homogeneity over the sample and the calibration of the monitoring system were performed using a silicon PIPS detector, placed in air in the same position as the biological samples to be irradiated. The irradiation proton fluence was found to be homogeneous to within ±2% over a circular field of 20 mm diameter. As preliminary biological experiment, two Human Head and Neck Squamous Carcinoma Cell lines (with different radiosensitivities) were irradiated with 2.9 MeV protons. The measured survival curves are compared to those obtained after X-ray irradiation, giving a Relative Biological Efficiency between 1.3 and 1.4.

  9. Schostakowitsch. Orchesterlieder (Vol. 2), Neeme Järvi / Werner Pfister

    Index Scriptorium Estoniae

    Pfister, Werner

    1996-01-01

    Uuest heliplaadist "Schostakowitsch. Orchesterlieder (Vol. 2): Sechs Romanzen op. 21, Sechs Gedichte op. 143a, Suite auf Verse von Michelangelo Buonarroti op. 145a. Göteborger Sinfoniker, Neeme Järvi". DG CD 447 085-2 (WD: 71'06") DDD

  10. Shostakovich: The Orchestral Songs Vol. 2 / Michael Tanner

    Index Scriptorium Estoniae

    Tanner, Michael

    1996-01-01

    Uuest heliplaadist "Shostakovich: The Orchestral Songs Vol. 2: Six Romances on texts by Japanese poets, Op. 21. Six Poems on Marina Tsvetayeva, Op. 143. Suite on Verses of Michelangelo, Op. 145. Gothenburg Symphony Orchestra, Neeme Järvi". DG 447 085-2GH (71 minutes:DDD)

  11. High value of the radiobiological parameter Dq correlates to expression of the transforming growth factor beta type II receptor in a panel of small cell lung cancer cell lines

    DEFF Research Database (Denmark)

    Hougaard, S; Krarup, M; Nørgaard, P;

    1998-01-01

    Our panel of SCLC cell lines have previously been examined for their radiobiological characteristics and sensitivity to treatment with TGF beta 1. In this study we examined the possible correlations between radiobiological parameters and the expression of the TGF beta type II receptor (TGF beta-r...... role for the repair of radiation induced DNA damage in SCLC....

  12. Characteristic 8 keV X rays possess radiobiological properties of higher-LET radiation.

    Science.gov (United States)

    Shridhar, Ravi; Estabrook, William; Yudelev, Mark; Rakowski, Joseph; Burmeister, Jay; Wilson, George D; Joiner, Michael C

    2010-03-01

    Electronic brachytherapy systems are being developed that can deliver X rays of varying energy depending on the material of a secondary target. A copper target produces characteristic 8 keV X rays. Our aim was to determine whether 8 keV X rays might deliver greater biological effectiveness than megavoltage photons. Cells of the U251 human glioma cell line were used to compare the biological effects of 8 keV X rays and (60)Co gamma rays in terms of relative biological effectiveness (RBE), oxygen enhancement ratio (OER), and DNA damage. The RBE at 50% and 10% survival was 2.6 and 1.9, respectively. At 50% survival, the OER for cells treated with 8 keV X rays was 1.6 compared with 3.0 for (60)Co gamma rays. The numbers of H2AX foci per Gy after treatment with 8 keV X rays and (60)Co gamma rays were similar; however, the size of the foci generated at 8 keV was significantly larger, possibly indicating more complex DNA damage. The mean area of H2AX foci generated by 8 keV X rays was 0.785 microm(2) (95% CI: 0.756-0.814) compared with 0.491 microm(2) (95% CI: 0.462-0.520) for (60)Co gamma rays (P X rays produce two to three times the biological effectiveness of megavoltage photons, with a radiobiological profile similar to higher-LET radiations.

  13. Radiobiological restrictions and tolerance doses of repeated single-fraction hdr-irradiation of intersecting small liver volumes for recurrent hepatic metastases

    Directory of Open Access Journals (Sweden)

    Wust Peter

    2010-05-01

    Full Text Available Abstract Background To assess radiobiological restrictions and tolerance doses as well as other toxic effects derived from repeated applications of single-fraction high dose rate irradiation of small liver volumes in clinical practice. Methods Twenty patients with liver metastases were treated repeatedly (2 - 4 times at identical or intersecting locations by CT-guided interstitial brachytherapy with varying time intervals. Magnetic resonance imaging using the hepatocyte selective contrast media Gd-BOPTA was performed before and after treatment to determine the volume of hepatocyte function loss (called pseudolesion, and the last acquired MRI data set was merged with the dose distributions of all administered brachytherapies. We calculated the BED (biologically equivalent dose for a single dose d = 2 Gy for different α/β values (2, 3, 10, 20, 100 based on the linear-quadratic model and estimated the tolerance dose for liver parenchyma D90 as the BED exposing 90% of the pseudolesion in MRI. Results The tolerance doses D90 after repeated brachytherapy sessions were found between 22 - 24 Gy and proved only slightly dependent on α/β in the clinically relevant range of α/β = 2 - 10 Gy. Variance analysis showed a significant dependency of D90 with respect to the intervals between the first irradiation and the MRI control (p 90 and the pseudolesion's volume. No symptoms of liver dysfunction or other toxic effects such as abscess formation occurred during the follow-up time, neither acute nor on the long-term. Conclusions Inactivation of liver parenchyma occurs at a BED of approx. 22 - 24 Gy corresponding to a single dose of ~10 Gy (α/β ~ 5 Gy. This tolerance dose is consistent with the large potential to treat oligotopic and/or recurrent liver metastases by CT-guided HDR brachytherapy without radiation-induced liver disease (RILD. Repeated small volume irradiation may be applied safely within the limits of this study.

  14. Automation of the particle dosimetry and the dose application for radiobiological experiments at a vertical proton beam

    CERN Document Server

    Moertel, H; Eyrich, W; Fritsch, M; Distel, L

    2002-01-01

    A facility with a vertical beam for radiobiological experiments with low-energy protons has been setup at the Tandem accelerator at Erlangen. This energy region is optimal to investigate the biological effects of the linear energy transfer in the Bragg region under physiological conditions. A new automated data acquisition system for dosimetry and monitoring based on a personal computer was developed and optimized for this setup. A specially designed sample holder offers possibilities of cooling or changing of atmosphere during irradiation. First irradiations of biological samples have shown the functionality of the setup.

  15. VolP开始走向实用

    Institute of Scientific and Technical Information of China (English)

    Russ Anensman

    2006-01-01

    <正>德州仪器(TI)的Tom Flanagan已为早期基于IP协议的语音(VolP)技术天花乱坠的广告宣传进入实用等待了10年之久。TI VoIP部技术战略总监Flanagan说:“我不可能告诉你实现这一点需要多少时间。”

  16. Componentes volátiles de mamey (mammea americana L.)

    OpenAIRE

    Alicia Lucía Morales; William Arguello; Gustavo García; Iván Herrera

    2010-01-01

    Los componentes volátiles del aroma de mamey (Mammea americana L), fueron extraídos utilizando el método de destilación por arrastre con vapor-extracción simultánea con solvente orgánico. El extracto fue prefraccionado por cromatografía en columna en silica gel con gradiente discontinuo Pentano: Éter etílico para obtener tres fracciones que fueron analizadas por CGAR y CGAR-EM. Se detectaron 34 compuestos, de los cuales fueron identificados 22, siendo los componentes mayoritarios: Furfural (7...

  17. Componentes volátiles de mamey (mammea americana l.)

    OpenAIRE

    Morales, Alicia Lucía; Arguello, William; García, Gustavo; Herrera, Iván

    2010-01-01

    Los componentes volátiles del aroma de mamey (Mammea americana L), fueron extraídos utilizando el método de destilación por arrastre con vapor-extracción simultánea con solvente orgánico. El extracto fue prefraccionado por cromatografía en columna en silica gel con gradiente discontinuo Pentano: Éter etílico para obtener tres fracciones que fueron analizadas por CGAR y CGAR-EM. Se detectaron 34 compuestos, de los cuales fueron identificados 22, siendo los componentes mayoritarios: Furfural (7...

  18. Mastoplastia reductora en L para grandes volúmenes

    OpenAIRE

    Fernandez, Claudio de Barros

    2013-01-01

    Las primeras descripciones de las mastoplastias fueron atribuidas a Paulus Aegineta en 625-690d.C. 4, con una resección de ginecomastia por el surco sub-mamario. Posteriormente, muchas técnicas fueron descritas para la disminución del órgano. Clásicamente, fueron consideradas mamas grandes aquellas con volúmenes resecados más grandes que 600 gr., siendo la mayoría tratadas tras cicatrices en T invertido. El objetivo de ese estudio es mostrar que es posible tratar mamas grandes con cicatrices ...

  19. Mastoplastia reductora en l para grandes volúmenes

    OpenAIRE

    De Barros Fernandez, Claudio

    2012-01-01

    Las primeras descripciones de las mastoplastias fueron atribuidas a Paulus Aegineta en 625-690d.C. 4, con una resección de ginecomastia por el surco sub-mamario. Posteriormente, muchas técnicas fueron descritas para la disminución del órgano. Clásicamente, fueron consideradas mamas grandes aquellas con volúmenes resecados más grandes que 600 gr., siendo la mayoría tratadas tras cicatrices en T invertido. El objetivo de ese estudio es mostrar que es posible tratar mamas grandes ...

  20. Sensitometria : sistema analògic versus digital. Vol. 2

    OpenAIRE

    Llunas i Pérez, Pere; Mur i Sanabre, Carme de

    2004-01-01

    Aquesta publicació vol ser una ajuda per a totes aquelles persones interessades en el coneixement dels materials fotogràfics fotoquímics i digitals i en el seu processament químic i digital. Al mateix temps pretén que alguns apartats d'aquesta disciplina siguin més propers a la pràctica fotogràfica. L'obra es composa d'il·lustracions que han estat dissenyades amb una finalitat docent; aquestes il·lustracions s'utilitzen a classe per a desenvolupar els temes que configuren el programa de l'ass...

  1. Diagramas de flujo y volúmenes de control

    OpenAIRE

    Fernández Torres, María José

    2010-01-01

    En este vídeo se explican los conceptos de DIAGRAMA DE FLUJO y de VOLÚMEN DE CONTROL aplicados a la Ingeniería Química. Se detalla cómo se dibujan correctamente volúmenes de control y las corrientes que deben considerarse en varios casos. Participan: Voz: Dra. María José Fernández Torres; Colaboran: Dra. María Dolores Saquete Ferrándiz y Dr. Francisco Ruiz Beviá.

  2. Radiobiological Effects of Alpha-Particles from Astatine-211: From DNA Damage to Cell Death

    Energy Technology Data Exchange (ETDEWEB)

    Claesson, Kristina

    2011-05-15

    In recent years, the use of high linear energy transfer (LET) radiation for radiotherapeutic applications has gained increased interest. Astatine-211 (211At) is an alpha-particle emitting radionuclide, promising for targeted radioimmunotherapy of isolated tumor cells and microscopic clusters. To improve development of safe radiotherapy using 211At it is important to increase our knowledge of the radiobiological effects in cells. During radiotherapy, both tumors and adjacent normal tissue will be irradiated and therefore, it is of importance to understand differences in the radio response between proliferating and resting cells. The aim of this thesis was to investigate effects in fibroblasts with different proliferation status after irradiation with alpha-particles from 211At or X-rays, from inflicted DNA damage, to cellular responses and biological consequences. Throughout this work, irradiation was performed with alpha-particles from 211A or X-rays. The induction and repair of double-strand breaks (DSBs) in human normal fibroblasts were investigated using pulsed-field gel electrophoresis and fragment analysis. The relative biological effectiveness (RBE) of 211At for DSB induction varied between 1.4 and 3.1. A small increase of DSBs was observed in cycling cells compared to stationary cells. The repair kinetics was slower after 211At and more residual damage was found after 24 h. Comparison between cells with different proliferation status showed that the repair was inefficient in cycling cells with more residual damage, regardless of radiation quality. Activation of cell cycle arrests was investigated using immunofluorescent labeling of the checkpoint kinase Chk2 and by measuring cell cycle distributions with flow cytometry analysis. After alpha-particle irradiation, the average number of Chk2-foci was larger and the cells had a more affected cell cycle progression for several weeks compared with X-irradiated cells, indicating a more powerful arrest after 211At

  3. Brachytherapy optimization using radiobiological-based planning for high dose rate and permanent implants for prostate cancer treatment

    Science.gov (United States)

    Seeley, Kaelyn; Cunha, J. Adam; Hong, Tae Min

    2017-01-01

    We discuss an improvement in brachytherapy--a prostate cancer treatment method that directly places radioactive seeds inside target cancerous regions--by optimizing the current standard for delivering dose. Currently, the seeds' spatiotemporal placement is determined by optimizing the dose based on a set of physical, user-defined constraints. One particular approach is the ``inverse planning'' algorithms that allow for tightly fit isodose lines around the target volumes in order to reduce dose to the patient's organs at risk. However, these dose distributions are typically computed assuming the same biological response to radiation for different types of tissues. In our work, we consider radiobiological parameters to account for the differences in the individual sensitivities and responses to radiation for tissues surrounding the target. Among the benefits are a more accurate toxicity rate and more coverage to target regions for planning high-dose-rate treatments as well as permanent implants.

  4. Manipulation of radiobiological hypoxia in a human melanoma xenograft to exploit the bioreductive cytotoxicity of RSU-1069

    Energy Technology Data Exchange (ETDEWEB)

    Cole, S.; Stratford, I.J.; Adams, G.E. (Medical Research Council, Harwell (UK). Radiobiological Research Unit)

    1989-11-01

    RSU-1069 (a 2-nitroimidazole) is known to be an efficient hypoxic cell radiosensitizer and potent cytotoxin for hypoxic cells in murine tumours (Chaplin et al. 1986). The authors demonstrated that the compound is also able to kill human melanoma cells, growing as a xenograft, provided the tumour blood supply is occluded for an hour or more, thereby substantially increasing the proportion of susceptible, hypoxic cells. Pharmacokinetic effects may also contribute to this phenomenon, as the effectiveness of bioreductive cytotoxic agents may increase with prolonged contact times (Stratford et al. 1986b). Hydralazine increased radiobiological hypoxia in the HX118 xenograft but this did not enhance the susceptibility of clonogenic melanoma cells to killing by RSU-1069. (author).

  5. Neutron field produced by 25 MeV deuteron on thick beryllium for radiobiological study; energy spectrum.

    Science.gov (United States)

    Takada, Masashi; Mihara, Erika; Sasaki, Michiya; Nakamura, Takashi; Honma, Toshihiko; Kono, Koji; Fujitaka, Kazunobu

    2004-01-01

    Biological data is necessary for estimation of protection from neutrons, but there is a lack of data on biological effects of neutrons for radiation protection. Radiological study on fast neutrons has been done at the National Institute of Radiological Sciences. An intense neutron source has been produced by 25 MeV deuterons on a thick beryllium target. The neutron energy spectrum, which is essential for neutron energy deposition calculation, was measured from thermal to maximum energy range by using an organic liquid scintillator and multi-sphere moderated 3He proportional counters. The spectrum of the gamma rays accompanying the neutron beam was measured simultaneously with the neutron spectrum using the organic liquid scintillator. The transmission by the shield of the spurious neutrons originating from the target was measured to be less than 1% by using the organic liquid scintillator placed behind the collimator. The measured neutron energy spectrum is useful in dose calculations for radiobiology studies.

  6. Anestesia volátil e monitorização anestésica.

    OpenAIRE

    Alexandre, Nuno; Costa, Margarida; Mascarenhas, Ramiro

    2009-01-01

    Os autores apresentam um texto de apoio à disciplina de anestesiologia do curso de Medicina Veterinária .Neste texto são abordadas diversas temáticas da anestesia volátil tais como: equipamentos utilizados em anestesia volátil, farmacologia dos anestésicos voláteis. A monitorização dos pacientes é abordada na vertente mecânica ou intrumental e na componente básica.

  7. Tail's Entropy and dose of critical annihilation: a new view of the problem radiobiological; Entropia de Tsallis y dosis de aniquilacion critica: una nueva vision del problema radiobiologico

    Energy Technology Data Exchange (ETDEWEB)

    Sotolongo Grau, O.; Rodriguez Perez, D.; Antoranz, J. C.

    2011-07-01

    The aim of this paper is to present a model based on a minimum radiobiological physical hypotheses containing known models as special cases, allowing to define operations of addition and multiplication dose survival probabilities to fit the experimental data.

  8. Componentes volátiles de mamey (mammea americana L.

    Directory of Open Access Journals (Sweden)

    Alicia Lucía Morales

    2010-07-01

    Full Text Available Los componentes volátiles del aroma de mamey (Mammea americana L, fueron extraídos utilizando el método de destilación por arrastre con vapor-extracción simultánea con solvente orgánico. El extracto fue prefraccionado por cromatografía en columna en silica gel con gradiente discontinuo Pentano: Éter etílico para obtener tres fracciones que fueron analizadas por CGAR y CGAR-EM. Se detectaron 34 compuestos, de los cuales fueron identificados 22, siendo los componentes mayoritarios: Furfural (7281 ^ig/kg y E-Famesol (2145 ng/kg

  9. Index to Nuclear Safety. A technical progress review by chronology, permuted title, and author. Vol. 11, No. 1--Vol. 17, No. 6

    Energy Technology Data Exchange (ETDEWEB)

    Cottrell, W.B.; Klein, A.

    1977-02-23

    This index to Nuclear Safety covers articles in Nuclear Safety Vol. 11, No. 1 (Jan.-Feb. 1970), through Vol. 17, No. 6 (Nov.-Dec. 1976). The index includes a chronological list of articles (including abstract) followed by KWIC and Author Indexes. Nuclear Safety, a bimonthly technical progress review prepared by the Nuclear Safety Information Center, covers all safety aspects of nuclear power reactors and associated facilities. The index lists over 350 technical articles in the last six years of publication.

  10. SU-E-T-398: Evaluation of Radiobiological Parameters Using Serial Tumor Imaging During Radiotherapy as An Inverse Ill-Posed Problem

    Energy Technology Data Exchange (ETDEWEB)

    Chvetsov, A; Sandison, G; Schwartz, J; Rengan, R [University of Washington, Seattle, WA (United States)

    2015-06-15

    Purpose: Combination of serial tumor imaging with radiobiological modeling can provide more accurate information on the nature of treatment response and what underlies resistance. The purpose of this article is to improve the algorithms related to imaging-based radiobilogical modeling of tumor response. Methods: Serial imaging of tumor response to radiation therapy represents a sum of tumor cell sensitivity, tumor growth rates, and the rate of cell loss which are not separated explicitly. Accurate treatment response assessment would require separation of these radiobiological determinants of treatment response because they define tumor control probability. We show that the problem of reconstruction of radiobiological parameters from serial imaging data can be considered as inverse ill-posed problem described by the Fredholm integral equation of the first kind because it is governed by a sum of several exponential processes. Therefore, the parameter reconstruction can be solved using regularization methods. Results: To study the reconstruction problem, we used a set of serial CT imaging data for the head and neck cancer and a two-level cell population model of tumor response which separates the entire tumor cell population in two subpopulations of viable and lethally damage cells. The reconstruction was done using a least squared objective function and a simulated annealing algorithm. Using in vitro data for radiobiological parameters as reference data, we shown that the reconstructed values of cell surviving fractions and potential doubling time exhibit non-physical fluctuations if no stabilization algorithms are applied. The variational regularization allowed us to obtain statistical distribution for cell surviving fractions and cell number doubling times comparable to in vitro data. Conclusion: Our results indicate that using variational regularization can increase the number of free parameters in the model and open the way to development of more advanced

  11. Editor's welcome, PORTAL, Vol. 1, No. 2, July 2004

    Directory of Open Access Journals (Sweden)

    Paul Allatson

    2005-03-01

    Full Text Available Since the highly successful inauguration of PORTAL in January 2004, we have received many kind expressions of support from international studies practitioners in a range of fields, and from such places as Canada, Italy, Mexico, Nigeria, New Zealand, Spain, Trinidad, the U.K., and the U.S.A. Particularly gratifying have been the endorsements of the journal and its publishing aims by people involved in their own electronic publishing enterprises. For their generous responses to PORTAL, the Editorial Committee would like to express its collective appreciation to the following people: Professor Jean-Marie Volet, of the University of Western Australia, and the guiding editor of the ground-breaking e-journal Mots Pluriels (www.arts.uwa.edu.au/MotsPluriels; and Francis Leo Collins, member of the Editorial Committee for the Graduate Journal of Asia Pacific Studies (GJAPS, based in Auckland, New Zealand. PORTAL's readers may be interested in the current call for papers from GJAPS (www.arts.auckland.ac.nz/gjaps, for a special issue on "Imagining the Asia-Pacific" (deadline October 31, 2004. This issue of PORTAL contains essays that cover wide terrain: the Chilean diasporic community in Australia; the world of German intellectuals; contemporary Mexican socio-political movements; rural-urban migration in China; and transnational advocacy networks and election monitoring in the Philippines, Chile, Nicaragua and Mexico. In the cultural section of this issue, we are delighted to present a short story from the noted German Studies scholar Anthony Stephens, and the first half of a beautiful, deeply poetic and haunting novel entitled Son, from the London-based writer and art-critic Jennifer Higgie. The novel’s second and final part will appear in PORTAL vol. 2, no. 1, in January 2005. On a different note, we would like to express our support for the inaugural Ubud Writers and Readers Festival, to be held in Ubud, Bali, from October 11 to 17, 2004. The Festival

  12. Comprehensive brachytherapy physical and clinical aspects

    CERN Document Server

    Baltas, Dimos; Meigooni, Ali S; Hoskin, Peter J

    2013-01-01

    Modern brachytherapy is one of the most important oncological treatment modalities requiring an integrated approach that utilizes new technologies, advanced clinical imaging facilities, and a thorough understanding of the radiobiological effects on different tissues, the principles of physics, dosimetry techniques and protocols, and clinical expertise. A complete overview of the field, Comprehensive Brachytherapy: Physical and Clinical Aspects is a landmark publication, presenting a detailed account of the underlying physics, design, and implementation of the techniques, along with practical guidance for practitioners. Bridging the gap between research and application, this single source brings together the technological basis, radiation dosimetry, quality assurance, and fundamentals of brachytherapy. In addition, it presents discussion of the most recent clinical practice in brachytherapy including prostate, gynecology, breast, and other clinical treatment sites. Along with exploring new clinical protocols, ...

  13. A radiobiology-based inverse treatment planning method for optimisation of permanent l-125 prostate implants in focal brachytherapy

    Science.gov (United States)

    Haworth, Annette; Mears, Christopher; Betts, John M.; Reynolds, Hayley M.; Tack, Guido; Leo, Kevin; Williams, Scott; Ebert, Martin A.

    2016-01-01

    Treatment plans for ten patients, initially treated with a conventional approach to low dose-rate brachytherapy (LDR, 145 Gy to entire prostate), were compared with plans for the same patients created with an inverse-optimisation planning process utilising a biologically-based objective. The ‘biological optimisation’ considered a non-uniform distribution of tumour cell density through the prostate based on known and expected locations of the tumour. Using dose planning-objectives derived from our previous biological-model validation study, the volume of the urethra receiving 125% of the conventional prescription (145 Gy) was reduced from a median value of 64% to less than 8% whilst maintaining high values of TCP. On average, the number of planned seeds was reduced from 85 to less than 75. The robustness of plans to random seed displacements needs to be carefully considered when using contemporary seed placement techniques. We conclude that an inverse planning approach to LDR treatments, based on a biological objective, has the potential to maintain high rates of tumour control whilst minimising dose to healthy tissue. In future, the radiobiological model will be informed using multi-parametric MRI to provide a personalised medicine approach.

  14. Radiobiological long-term accumulation of environmental alpha radioactivity in extracted human teeth and animal bones in Malaysia.

    Science.gov (United States)

    Almayahi, B A; Tajuddin, A A; Jaafar, M S

    2014-03-01

    In this study, the radiobiological analysis of natural alpha emitters in extracted human teeth and animal bones from Malaysia was estimated. The microdistributions of alpha particles in tooth and bone samples were measured using CR-39 alpha-particle track detectors. The lowest and highest alpha emission rates in teeth in the Kedah and Perak states were 0.0080 ± 0.0005 mBq cm(-2) and 0.061 ± 0.008 mBq cm(-2), whereas those of bones in the Perlis and Kedah states were 0.0140 ± 0.0001 mBq cm(-2) and 0.7700 ± 0.0282 mBq cm(-2), respectively. The average alpha emission rate in male teeth was 0.0209 ± 0.0008 mBq cm(-2), whereas that of female teeth was 0.0199 ± 0.0010 mBq cm(-2). The alpha emission rate in teeth is higher in smokers (0.0228 ± 0.0008 mBq cm(-2)) than in non-smokers (0.0179 ± 0.0008 mBq cm(-2)). Such difference was found statistically significant (p < 0.01).

  15. Editor's welcome, PORTAL, Vol. 3, No. 1, January 2006

    Directory of Open Access Journals (Sweden)

    Paul Allatson

    2006-02-01

    Full Text Available Welcome to the first appearance of PORTAL for 2006 (vol. 3, no. 1, a special issue entitled ‘Other Worlds’ guest edited by James Goodman and Christina Ho from the Faculty of Humanities and Social Sciences, University of Technology Sydney (UTS. The papers collected in this special issue focus on what the guest editors call “the transformative power of social movements” that respond to the processes and discourses of globalization and globalism by generating alternative sites and spaces of agency, or ‘other worlds.’ The contributors to the issue originally presented papers at a conference held in April 2005 in Sydney, with the title ‘Other Worlds: Social Movements and the Making of Alternatives.’ That conference was organized by the Research Initiative on International Activism at UTS, and supported by the Research Committee on Social Movements and Collective Action of the International Sociological Association. The Editorial Committee of PORTAL would like to thank both institutions for their support of the event that led to this special issue. I would also like to thank Wayne Peake, Kate Barclay, and Murray Pratt for their editorial efforts in seeing this issue through to publication. The Editorial Committee is pleased to showcase in the Cultural Works Section a short meditative piece by local writer Joel Scott, who is currently undertaking studies in Pamplona, Spain. When considered in the context of the special issue’s discussions of ‘other worlds’ that precede it, Scott’s ‘God, We’re Not Immigrants! A Reflection on Moving and Staying,’ provides an evocative insight into the sociocultural and imaginative limits that may preclude the construction of alternative ‘worlds.’

  16. Index to Nuclear Safety. A technical progress review by chronology, permuted title, and author. Vol 11, No. 1 through Vol. 16, No. 6

    Energy Technology Data Exchange (ETDEWEB)

    Cottrell, W.B.; Klein, A.

    1976-04-01

    This index to Nuclear Safety covers articles in Nuclear Safety Vol. 11, No. 1 (Jan.-Feb. 1970) through Vol. 16, No. 6 (Nov.-Dec. 1975). Included in the index is a chronological list of articles (including abstract) followed by both a KWIC index and an Author Index. Nuclear Safety is a bimonthly technical progress review prepared by the Nuclear Safety Information Center and covers all safety aspects of nuclear power reactors and associated facilities. The index lists over 300 technical articles in the last six years of publication.

  17. Index to Nuclear Safety: a technical progress review by chronology, permuted title, and author. Vol. 11(1)--Vol. 18(6)

    Energy Technology Data Exchange (ETDEWEB)

    Cottrell, W.B.; Klein, A.

    1978-04-11

    This index to Nuclear Safety covers articles published in Nuclear Safety, Vol. 11, No. 1 (January-February 1970), through Vol. 18, No. 6 (November-December 1977). It is divided into three sections: a chronological list of articles (including abstracts) followed by a permuted-title (KWIC) index and an author index. Nuclear Safety, a bimonthly technical progress review prepared by the Nuclear Safety Information Center (NSIC), covers all safety aspects of nuclear power reactors and associated facilities. Over 450 technical articles published in Nuclear Safety in the last eight years are listed in this index.

  18. Arvustuse piirid ja auhinnad : mõtteid kirjanduskriitikast vol 2 / Jan Kaus

    Index Scriptorium Estoniae

    Kaus, Jan, 1971-

    2007-01-01

    Tänapäeva eesti kirjanduskriitikast. Vt. ka vol. 1: Kaus, Jan. Eetika, taburetiefekt ja jätkuv objektivisatsioon, Sirp, 15. juuni., lk. 7. Vastukaja: Raudam, Toomas. Arvustuse piiritused //Sirp (2007) 10. aug., lk. 9

  19. Siim Nestor soovitab : Tallinn Doom Night vol.1. Odessa Pop / Siim Nestor

    Index Scriptorium Estoniae

    Nestor, Siim, 1974-

    2006-01-01

    Soome doom-metal ansambel Reverend Bizarre üritusel "Tallinn Doom Night vol.1" 8. dets. klubis Rockstar's. Indipoppi viljelev Rootsi duo My Darling Yoy! üritusel "Odessa Pop" 9. dets. Tallinnas klubis KuKu

  20. SU-C-BRE-02: BED Vs. Local Control: Radiobiological Effect of Tumor Volume in Monte Carlo (MC) Lung SBRT Planning

    Energy Technology Data Exchange (ETDEWEB)

    Pokhrel, D; Badkul, R; Jiang, H; Estes, C; Park, J; Kumar, P; Wang, F [UniversityKansas Medical Center, Kansas City, KS (United States)

    2014-06-15

    Purpose: SBRT with hypofractionated dose schemata has emerged a compelling treatment modality for medically inoperable early stage lung cancer patients. It requires more accurate dose calculation and treatment delivery technique. This report presents the relationship between tumor control probability(TCP) and size-adjusted biological effective dose(sBED) of tumor volume for MC lung SBRT patients. Methods: Fifteen patients who were treated with MC-based lung SBRT to 50Gy in 5 fractions to PTVV100%=95% were studied. ITVs were delineated on MIP images of 4DCT-scans. PTVs diameter(ITV+5mm margins) ranged from 2.7–4.9cm (mean 3.7cm). Plans were generated using non-coplanar conformal arcs/beams using iPlan XVMC algorithm (BrainLABiPlan ver.4.1.2) for Novalis-TX with HD-MLCs and 6MVSRS(1000MU/min) mode, following RTOG-0813 dosimetric guidelines. To understand the known uncertainties of conventional heterogeneities-corrected/uncorrected pencil beam (PBhete/ PB-homo) algorithms, dose distributions were re-calculated with PBhete/ PB-homo using same beam configurations, MLCs and monitor units. Biologically effective dose(BED10) was computed using LQ-model with α/β=10Gy for meanPTV and meanITV. BED10-c*L, gave size-adjusted BED(sBED), where c=10Gy/cm and L=PTV diameter in centimeter. The TCP model was adopted from Ohri et al.(IJROBP, 2012): TCP = exp[sBEDTCD50]/ k /(1.0 + exp[sBED-TCD50]/k), where k=31Gy corresponding to TCD50=0Gy; and more realistic MC-based TCP was computed for PTV(V99%). Results: Mean PTV PB-hete TCP value was 6% higher, but, mean PTV PB-homo TCP value was 4% lower compared to mean PTV MC TCP. Mean ITV PB-hete/PB-homo TCP values were comparable (within ±3.0%) to mean ITV MC TCP. The mean PTV(V99%)had BED10=90.9±3.7%(median=92.2%),sBED=54.1±8.2%(median=53.5%) corresponding to mean MC TCP value of 84.8±3.3%(median=84.9%) at 2- year local control. Conclusion: The TCP model which incorporates BED10 and tumor diameter indicates that radiobiological

  1. Reseña: Critical Studies on Corporate Responsibility, Governance and Sustainability, Vol. 4 y 6

    Directory of Open Access Journals (Sweden)

    Adrián Zicari

    2014-10-01

    Full Text Available Corporate Social Irresponsibility: A Challenging Concept. Series: Critical Studies on Corporate Responsibility, Governance and Sustainability, Vol. 4. Ralph Tench, William Sun and Brian Jones, 2012, Emerald Group Publishing Limited, 315 pages. Communicating Corporate Social Responsibility Perspectives and Practice. Series: Critical Studies on Corporate Responsibility, Governance and Sustainability, Vol. 6. Ralph Tench, William Sun and Brian Jones, 2014, Emerald Group Publishing Limited, 456 pages

  2. Radiobiological risk estimates of adverse events and secondary cancer for proton and photon radiation therapy of pediatric medulloblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Brodin, N. Patrik (Radiation Medicine Research Center, Dept. of Radiation Oncology, Rigshospitalet, Univ. of Copenhagen (Denmark); Niels Bohr Inst., Faculty of Sciences, Univ. of Copenhagen (Denmark)), e-mail: brodin.patrik@gmail.com; Munck af Rosenschoeld, Per; Aznar, Marianne C.; Vogelius, Ivan R. (Radiation Medicine Research Center, Dept. of Radiation Oncology, Rigshospitalet, Univ. of Copenhagen (Denmark)); Kiil-Berthelsen, Anne (Radiation Medicine Research Center, Dept. of Radiation Oncology, Rigshospitalet, Univ. of Copenhagen (Denmark); Dept. of Clinical Physiology and Nuclear Medicine, Centre of Diagnostic Investigations, Rigshospitalet, Univ. of Copenhagen (Denmark)); Nilsson, Per; Bjoerk-Eriksson, Thomas (Dept. of Oncology, Skaane Univ. Hospital and Lund Univ., Lund (Sweden)); Lannering, Birgitta (Dept. of Paediatric Oncology, The Queen Silvia Children' s Hospital, Gothenburg (Sweden))

    2011-08-15

    Introduction. The aim of this model study was to estimate and compare the risk of radiation-induced adverse late effects in pediatric patients with medulloblastoma (MB) treated with either three-dimensional conformal radiotherapy (3D CRT), inversely-optimized arc therapy (RapidArc (RA)) or spot-scanned intensity-modulated proton therapy (IMPT). The aim was also to find dose-volume toxicity parameters relevant to children undergoing RT to be used in the inverse planning of RA and IMPT, and to use in the risk estimations. Material and methods. Treatment plans were created for all three techniques on 10 pediatric patients that have been treated with craniospinal irradiation (CSI) at our institution in 2007-2009. Plans were generated for two prescription CSI doses, 23.4 Gy and 36 Gy. Risk estimates were based on childhood cancer survivor data when available and secondary cancer (SC) risks were estimated as a function of age at exposure and attained age according to the organ-equivalent dose (OED) concept. Results. Estimates of SC risk was higher for the RA plans and differentiable from the estimates for 3D CRT at attained ages above 40 years. The risk of developing heart failure, hearing loss, hypothyroidism and xerostomia was highest for the 3D CRT plans. The risks of all adverse effects were estimated as lowest for the IMPT plans, even when including secondary neutron (SN) irradiation with high values of the neutron radiation weighting factors (WR{sub neutron}). Conclusions. When comparing RA and 3D CRT treatment for pediatric MB it is a matter of comparing higher SC risk against higher risks of non-cancer adverse events. Considering time until onset of the different complications is necessary to fully assess patient benefit in such a comparison. The IMPT plans, including SN dose contribution, compared favorably to the photon techniques in terms of all radiobiological risk estimates

  3. Characterization of neutron beams for boron neutron capture therapy: in-air radiobiological dosimetry.

    Science.gov (United States)

    Yamamoto, Tetsuya; Matsumura, Akira; Yamamoto, Kazuyoshi; Kumada, Hiroaki; Hori, Naohiko; Torii, Yoshiya; Shibata, Yasushi; Nose, Tadao

    2003-07-01

    The survival curves and the RBE for the dose components generated in boron neutron capture therapy (BNCT) were determined separately in neutron beams at Japan Research Reactor No. 4. The surviving fractions of V79 Chinese hamster cells with or without 10B were obtained using an epithermal neutron beam (ENB), a mixed thermal-epithermal neutron beam (TNB-1), and a thermal (TNB-2) neutron beam; these beams were used or are planned for use in BNCT clinical trials. The cell killing effect of the neutron beam in the presence or absence of 10B was highly dependent on the neutron beam used and depended on the epithermal and fast-neutron content of the beam. The RBEs of the boron capture reaction for ENB, TNB-1 and TNB-2 were 4.07 +/- 0.22, 2.98 +/- 0.16 and 1.42 +/- 0.07, respectively. The RBEs of the high-LET dose components based on the hydrogen recoils and the nitrogen capture reaction were 2.50 +/- 0.32, 2.34 +/- 0.30 and 2.17 +/- 0.28 for ENB, TNB-1 and TNB-2, respectively. The RBEs of the neutron and photon components were 1.22 +/- 0.16, 1.23 +/- 0.16, and 1.21 +/- 0.16 for ENB, TNB-1 and TNB-2, respectively. The approach to the experimental determination of RBEs outlined in this paper allows the RBE-weighted dose calculation for each dose component of the neutron beams and contributes to an accurate inter-beam comparison of the neutron beams at the different facilities employed in ongoing and planned BNCT clinical trials.

  4. Development of a tool computer to compensate for interruptions of treatment and radiobiological comparisons Tr in external radiotherapy; Desarrollo de una herramienta informatica para la compensacion de interrupciones de tratamiento y comparaciones radiobiologicas en radioterapia externa

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Pacho, J. A.; Sena Espinel, E.; Verde Velasco, J. M.; Garcia Repiso, S.; Perez Alvarez, M. E.; Delgado Apaaricio, J. M.; Martin Rincon, C.; Saez Beltran, M.; Gomez Gonzalez, N.; Cons Perez, N.

    2013-07-01

    Outages unscheduled in the course of external beam radiation treatments, and the loss of probability of tumour control (TCP), which make it necessary to have a tool that allows the adjustment of the compensation of the absorbed dose required to keep the biological effect on the tumor, controlling the possible impact on the organ at risk. In order to perform this radiobiological quickly setting has been developed a software application that also allows comparison of treatments with different subdivisions from the point of view of radiobiological. (Author)

  5. Boron neutron capture therapy at the Institute of Medical Radiobiology (IMR) and Paul Scherrer Institute (PSI)

    Science.gov (United States)

    Argentini, M.; Arkuszewski, J.; Crawford, John F.; Larsson, B.; Stepanek, Jiri; Teichmann, Sarah; Weinreich, R.

    1997-02-01

    Although all of the over 200 patients treated with NCT have been irradiated by reactor-produced neutrons, in the present climate of public opinion one cannot expect the routine use of nuclear reactors in hospitals or clinics to be tolerated. While there are several other methods of producing neutrons in the necessary quantities, the Paul Scherrer Institute (PSI) is very well placed to develop techniques base don spallation, in which a beam of protons hits a production target of some convenient material such as tungsten. Because spallation produces neutrons of very similar energies to reactors, the problem of moderating them to keV energies is rather similar. However, there is an additional component of high-energy neutrons, whose intensity depends on the energy of the initial beam, which has to be taken into account in any practical design. Simulations using the well-known codes LAHET, MCNP and GEANT show that a 100 (mu) A beam of 72 MeV protons, well within the capabilities of PSI, could produce enough keV neutrons for therapy.

  6. Glioblastoma stem cells: radiobiological response to ionising radiations of different qualities.

    Science.gov (United States)

    Pecchia, I; Dini, V; Ricci-Vitiani, L; Biffoni, M; Balduzzi, M; Fratini, E; Belli, M; Campa, A; Esposito, G; Cirrone, G; Romano, F; Stancampiano, C; Pelacchi, F; Pallini, R; Tabocchini, M A

    2015-09-01

    Glioblastoma multiforme (GBM) is the most common and malignant primary brain tumour, with very poor prognosis. The high recurrence rate and failure of conventional treatments are expected to be related to the presence of radio-resistant cancer stem cells (CSCs) inside the tumour mass. CSCs can both self-renew and differentiate into the heterogeneous lineages of cancer cells. Recent evidence showed a higher effectiveness of C-ions and protons in inactivating CSCs, suggesting a potential advantage of Hadrontherapy compared with conventional radiotherapy for GBM treatment. To investigate the mechanisms involved in the molecular and cellular responses of CSCs to ionising radiations, two GBM stem cell (GSC) lines, named lines 1 and 83, which were derived from patients with different clinical outcomes and having different metabolic profiles (as shown by NMR spectroscopy), were irradiated with (137)Cs photons and with protons or C-ions of 62 MeV u(-1) in the dose range of 5-40 Gy. The biological effects investigated were: cell death, cell cycle progression, and DNA damage induction and repair. Preliminary results show a different response to ionising radiation between the two GSC lines for the different end points investigated. Further experiments are in progress to consolidate the data and to get more insights on the influence of radiation quality.

  7. Radiobiological analysis of the field in field technique in breast cancer radiotherapy treatments

    Energy Technology Data Exchange (ETDEWEB)

    Medel B, E.; Vasquez R, M. A. [IMSS, Centro Medico Nacional Manuel Avila Camacho, Calle 2 Nte. 2004, Barrio de San Francisco, 72090 Puebla, Pue. (Mexico); Tejeda M, G., E-mail: marcosalivasquez@gmail.com [Benemerita Universidad Autonoma de Puebla, Facultad de Ciencias Fisico Matematicas, Av. San Claudio y 18 Sur, Ciudad Universitaria, 72570 Puebla, Pue. (Mexico)

    2015-10-15

    Full text: In vivo dosimetry was performed in 6 unilateral breast cancer patients treated with external beam radiation therapy in order to evaluate the dose calculated by the radiotherapy treatment planning system (Xi O, ELEKTA). Results show a maximum difference of 0.473 Gy between the dose calculated by the treatment planning system and the dose measured in vivo using solid state detectors. Based on the DVHs statistics, tumor control probability (Tcp) was obtained using the Target-Poisson model, with the following Tcp parameters: α=0.288/Gy, α{sub s}pread= 0.13 and α/β=4.9 Gy. Tcp average obtained for the Clinical Tumor Volume (Ctv) is 35.1% and for Supra Clavicle Volume (Scv) is 35.345%. Finally using Lyman model Normal Tissue Complication Probability (Ntcp) was obtained for the following endpoints: contralateral breast fibrosis, lung radiation pneumonitis and heart pericarditis. Nonetheless the Ntcp values are not high; the improvement of the Tcp based on this plan makes Ntcp for lung radiation pneumonitis reach the 100% of probability in some cases. (Author)

  8. Present Status of Radiotherapy in Clinical Practice

    Science.gov (United States)

    Duehmke, Eckhart

    Aims of radiation oncology are cure from malignant diseases and - at the same time preservation of anatomy (e.g. female breast, uterus, prostate) and organ functions (e.g. brain, eye, voice, sphincter ani). At present, methods and results of clinical radiotherapy (RT) are based on experiences with natural history and radiobiology of malignant tumors in properly defined situations as well as on technical developments since World War II in geometrical and biological treatment planning in teletherapy and brachytherapy. Radiobiological research revealed tolerance limits of healthy tissues to be respected, effective total treatment doses of high cure probability depending on histology and tumor volume, and - more recently - altered fractionation schemes to be adapted to specific growth fractions and intrinsic radiosensitivities of clonogenic tumor cells. In addition, Biological Response Modifiers (BRM), such as cis-platinum, oxygen and hyperthermia may steepen cell survival curves of hypoxic tumor cells, others - such as tetrachiordekaoxid (TCDO) - may enhance repair of normal tissues. Computer assisted techniques in geometrical RT-planning based on individual healthy and pathologic anatomy (CT, MRT) provide high precision RT for well defined brain lesions by using dedicated linear accelerators (Stereotaxy). CT-based individual tissue compensators help with homogenization of distorted dose distributions in magna field irradiation for malignant lymphomas and with total body irradiation (TBI) before allogeneic bone marrow transplantation, e.g. for leukemia. RT with fast neutrons, Boron Neutron Capture Therapy (BNCT), RT with protons and heavy ions need to be tested in randomized trials before implementation into clinical routine.

  9. The radiobiology of prostate cancer including new aspects of fractionated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, Jack F. [Medical School of Wisconsin Univ., Madison (United States). Dept. of Human Oncology

    2005-05-01

    Total radiation dose is not a reliable measure of biological effect when dose-per-fraction or dose-rate is changed. Large differences in biological effectiveness (per gray) are seen between the 2 Gy doses of external beam radiotherapy and the large boost doses given at high dose-rate from afterloading sources. The effects are profoundly different in rapidly or slowly proliferating tissues, that is for most tumors versus late complications. These differences work the opposite way round for prostate tumors versus late complications compared with most other types of tumor. Using the Linear-Quadratic formula it is aimed to explain these differences, especially for treatments of prostate cancer. The unusually slow growth rate of prostate cancers is associated with their high sensitivity to increased fraction size, so a large number of small fractions, such as 35 or 40 'daily' doses of 2 Gy, is not an optimum treatment. Theoretical modeling shows a stronger enhancement of tumor effect than of late complications for larger (and fewer) fractions, in prostate tumors uniquely. Biologically Effective Doses and Normalized Total Doses (in 2 Gy fraction equivalents) are given for prostate tumor, late rectal reactions, and - a new development - acute rectal mucosa. Tables showing the change of fraction-size sensitivity (the alpha/beta ratio) with proliferation rates of tissues lead to the association of slow cell doubling times in prostate tumors with small alpha/beta ratios. Clinical evidence to confirm this biological expectation is reviewed. The alpha/beta ratios of prostate tumors appear to be as low as 1.5 Gy (95% confidence interval 1.3-1.8 Gy), in contrast with the value of about 10 Gy for most other types of tumor. The important point is that alpha/beta ratio=1.5 Gy appears to be significantly less than the alpha/beta ratio=3 Gy for late complications in rectal tissues. Such differences are also emerging from recent clinical results. From this important

  10. A radiobiological model of metastatic burden reduction for molecular radiotherapy: application to patients with bone metastases

    Science.gov (United States)

    Denis-Bacelar, Ana M.; Chittenden, Sarah J.; Murray, Iain; Divoli, Antigoni; McCready, V. Ralph; Dearnaley, David P.; O’Sullivan, Joe M.; Johnson, Bernadette; Flux, Glenn D.

    2017-04-01

    Skeletal tumour burden is a biomarker of prognosis and survival in cancer patients. This study proposes a novel method based on the linear quadratic model to predict the reduction in metastatic tumour burden as a function of the absorbed doses delivered from molecular radiotherapy treatments. The range of absorbed doses necessary to eradicate all the bone lesions and to reduce the metastatic burden was investigated in a cohort of 22 patients with bone metastases from castration-resistant prostate cancer. A metastatic burden reduction curve was generated for each patient, which predicts the reduction in metastatic burden as a function of the patient mean absorbed dose, defined as the mean of all the lesion absorbed doses in any given patient. In the patient cohort studied, the median of the patient mean absorbed dose predicted to reduce the metastatic burden by 50% was 89 Gy (interquartile range: 83–105 Gy), whilst a median of 183 Gy (interquartile range: 107–247 Gy) was found necessary to eradicate all metastases in a given patient. The absorbed dose required to eradicate all the lesions was strongly correlated with the variability of the absorbed doses delivered to multiple lesions in a given patient (r  =  0.98, P  <  0.0001). The metastatic burden reduction curves showed a potential large reduction in metastatic burden for a small increase in absorbed dose in 91% of patients. The results indicate the range of absorbed doses required to potentially obtain a significant survival benefit. The metastatic burden reduction method provides a simple tool that could be used in routine clinical practice for patient selection and to indicate the required administered activity to achieve a predicted patient mean absorbed dose and reduction in metastatic tumour burden.

  11. SU-E-T-664: Radiobiological Modeling of Prophylactic Cranial Irradiation in Mice

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D; Debeb, B; Woodward, W [MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: Prophylactic cranial irradiation (PCI) is a clinical technique used to reduce the incidence of brain metastasis and improve overall survival in select patients with ALL and SCLC, and we have shown the potential of PCI in select breast cancer patients through a mouse model (manuscript in preparation). We developed a computational model using our experimental results to demonstrate the advantage of treating brain micro-metastases early. Methods: MATLAB was used to develop the computational model of brain metastasis and PCI in mice. The number of metastases per mouse and the volume of metastases from four- and eight-week endpoints were fit to normal and log-normal distributions, respectively. Model input parameters were optimized so that model output would match the experimental number of metastases per mouse. A limiting dilution assay was performed to validate the model. The effect of radiation at different time points was computationally evaluated through the endpoints of incidence, number of metastases, and tumor burden. Results: The correlation between experimental number of metastases per mouse and the Gaussian fit was 87% and 66% at the two endpoints. The experimental volumes and the log-normal fit had correlations of 99% and 97%. In the optimized model, the correlation between number of metastases per mouse and the Gaussian fit was 96% and 98%. The log-normal volume fit and the model agree 100%. The model was validated by a limiting dilution assay, where the correlation was 100%. The model demonstrates that cells are very sensitive to radiation at early time points, and delaying treatment introduces a threshold dose at which point the incidence and number of metastases decline. Conclusion: We have developed a computational model of brain metastasis and PCI in mice that is highly correlated to our experimental data. The model shows that early treatment of subclinical disease is highly advantageous.

  12. Radiation-Therapeutic Agent Clinical Trials: Leveraging Advantages of a National Cancer Institute Programmatic Collaboration.

    Science.gov (United States)

    Takebe, Naoko; Ahmed, Mansoor M; Vikram, Bhadrasain; Bernhard, Eric J; Zwiebel, James; Norman Coleman, C; Kunos, Charles A

    2016-10-01

    A number of oncology phase II radiochemotherapy trials with promising results have been conducted late in the overall experimental therapeutic agent development process. Accelerated development and approval of experimental therapeutic agents have stimulated further interest in much earlier radiation-agent studies to increase the likelihood of success in phase III trials. To sustain this interest, more forward-thinking preclinical radiobiology experimental designs are needed to improve discovery of promising radiochemotherapy plus agent combinations for clinical trial testing. These experimental designs should better inform next-step radiation-agent clinical trial dose, schedule, exposure, and therapeutic effect. Recognizing the need for a better strategy to develop preclinical data supporting radiation-agent phase I or II trials, the National Cancer Institute (NCI)-Cancer Therapy Evaluation Program (CTEP) and the NCI-Molecular Radiation Therapeutics Branch of the Radiation Research Program have partnered to promote earlier radiobiology studies of CTEP portfolio agents. In this Seminars in Radiation Oncology article, four key components of this effort are discussed. First, we outline steps for accessing CTEP agents for preclinical testing. Second, we propose radiobiology studies that facilitate transition from preclinical testing to early phase trial activation. Third, we navigate steps that walk through CTEP agent strategic development paths available for radiation-agent testing. Fourth, we highlight a new NCI-sponsored cooperative agreement grant supporting in vitro and in vivo radiation-CTEP agent testing that informs early phase trial designs. Throughout the article, we include contemporary examples of successful radiation-agent development initiatives.

  13. Patient-Specific Dosimetry and Radiobiological Modeling of Targeted Radionuclide Therapy Grant - final report

    Energy Technology Data Exchange (ETDEWEB)

    George Sgouros, Ph.D.

    2007-03-20

    The broad, long-term objectives of this application are to 1. develop easily implementable tools for radionuclide dosimetry that can be used to predict normal organ toxicity and tumor response in targeted radionuclide therapy; and 2. to apply these tools to the analysis of clinical trial data in order to demonstrate dose-response relationships for radionuclide therapy treatment planning. The work is founded on the hypothesis that robust dose-response relationships have not been observed in targeted radionuclide therapy studies because currently available internal dosimetry methodologies are inadequate, failing to adequately account for individual variations in patient anatomy, radionuclide activity distribution/kinetics, absorbed dose-distribution, and absorbed dose-rate. To reduce development time the previously available software package, 3D-ID, one of the first dosimetry software packages to incorporate 3-D radionuclide distribution with individual patient anatomy; and the first to be applied for the comprehensive analysis of patient data, will be used as a platform to build the functionality listed above. The following specific aims are proposed to satisfy the long-term objectives stated above: 1. develop a comprehensive and validated methodology for converting one or more SPECT images of the radionuclide distribution to a 3-D representation of the cumulated activity distribution; 2. account for differences in tissue density and atomic number by incorporating an easily implementable Monte Carlo methodology for the 3-D dosimetry calculations; 3. incorporate the biologically equivalent dose (BED) and equivalent uniform dose (EUD) models to convert the spatial distribution of absorbed dose and dose-rate into equivalent single values that account for differences in dose uniformity and rate and that may be correlated with tumor response and normal organ toxicity; 4. test the hypothesis stated above by applying the resulting package to patient trials of targeted

  14. The Cuban Institute of Oncology and Radiobiology experience on the beliefs and opinions about digital rectal exam in urological patients

    Directory of Open Access Journals (Sweden)

    Isabel García Figueredo

    2016-07-01

    Full Text Available Resumen OBJETIVO Describir las creencias, los conocimientos y opiniones sobre el examen dígito rectal en un grupo de pacientes urológicos. MÉTODOS Se desarrolló un estudio descriptivo transversal donde se evaluó un cuestionario anónimo con 15 preguntas, dividido en tres bloques: 1 variables socio-demográficas; 2 retraso en ir a la consulta de urología y su inconformidad con la práctica del examen dígito rectal; 3 percepción de dolor y malestar durante el examen dígito rectal. El cuestionario fue aplicado a una muestra de conveniencia. RESULTADOS Se analizaron 84 encuestas aplicadas en el Instituto de Oncología y Radiobiología de Cuba. Los resultados mostraron que 70,24% de los participantes conocían en cierta medida sobre el cáncer de próstata y 64,29%, sobre el uso del antígeno prostático específico. Sólo 27% encontró útil realizarse el examen digito rectal. Los mayores impedimentos para asistir a la consulta del urólogo fueron: no someterse a una biopsia (79,76% y evadir la práctica del examen dígito rectal (66,66%. Además, se observó que 52,39% y 36,90% de los hombres se quejaron de dolor moderado y severo respectivamente, siendo traumático el examen dígito rectal en 61,9%. Sin embargo, 88,09% de los pacientes respondió que repetirían el examen al siguiente año y el 94,05% animaría a un amigo para someterse al él. CONCLUSIONES En la muestra de individuos estudiados, más de la mitad afirmó conocer sobre el cáncer de próstata y el antígeno prostático específico, sin embargo, no consideró provechoso someterse a un examen dígito rectal. Evitar someterse a una biopsia o al examen dígito rectal fueron los principales impedimentos para su asistencia al urólogo. A pesar de que en la mayoría de los pacientes, realizarse el examen dígito rectal fue traumático, estos consintieron en repetírselo en el futuro.

  15. Acquisition Review Quarterly. Vol. 4, No. 1, Winter 1997

    Science.gov (United States)

    1997-01-01

    Caruth Norene Blanch Managing Editor Editorial Assistant Pat Bartlett Layout and Design The Acquisition Review Quarterly is published quarterly for...Examples of system acting on behalf of the user. The customer failures whose root was failure of the soft- is responsible for accurately translating the...throughput of Test Board team via the Lotus Notes sys- medical data? What factors affect data tem and on the contents of clinical and compression and

  16. Architectures innovantes de systèmes de commandes de vol

    OpenAIRE

    Sghairi Haouati, Manel

    2010-01-01

    L'aboutissement aux Commandes de Vol Électriques (CDVE) des avions civils actuels s'est fait par étapes, après une longue maturation des différentes technologies mises en place. La prochaine étape est l'utilisation de communications intégralement numériques et d'actionneurs intelligents. Cette thèse propose de nouvelles architectures, en rupture avec l'état de l'art, avec de nouvelles répartitions des fonctions intelligentes entre l'avionique centrale (calculateurs de commandes de vols) et l'...

  17. MANHATTAN DISTRICT HISTORY PROJECT Y THE LOS ALAMOS PROJECT VOL. I INCEPTION UNTIL AUGUST 1945

    Energy Technology Data Exchange (ETDEWEB)

    Hawkins, D.

    1961-12-01

    THESE TWO VOLUMES CONSTITUTE A RECORD OF THE TECHNICAL, ADMINISTRATIVE , AND POLICY-MAKING ACTIVITIES OF THE LOS ALAMOS PROJECT (PROJECT Y) FROM ITS INCEPTION UNDER THE MANHATTAN DISTRICT THROUGH THE DEVELOPMENT OF THE ATOMIC BOMB (VOL. I), AND DURING THE PERIOD FOLLOWING THE END OF WORLD WAR II UNTIL THE MANHATTAN DISTRICT RELINQUISHED CONTROL TO THE ATOMIC ENERGY COMMISSION AS OF JANUARY 1947 (VOL. II). ALTHOUGH SECURITY REGULATIONS HAVE REQUIRED SOME DELETIONS IN THE ORIGINAL TEXT OF THE TWO VOLUMES, EVERY EFFORT HAS BEEN MADE TO RETAIN THE ORIGINAL LANGUAGE AND EXPRESSIONS OF THE AUTHORS.

  18. MANHATTAN DISTRICT HISTORY PROJECT Y THE LOS ALAMOS PROJECT VOL. II AUGUST 1945 THROUGH DECEMBER 1946

    Energy Technology Data Exchange (ETDEWEB)

    Truslow, E. C.; Smith, R. C.

    1961-12-01

    THESE TWO VOLUMES CONSTITUTE A RECORD OF THE TECHNICAL, ADMINISTRATIVE , AND POLICY-MAKING ACTIVITIES OF THE LOS ALAMOS PROJECT (PROJECT Y) FROM ITS INCEPTION UNDER THE MANHATTAN DISTRICT THROUGH THE DEVELOPMENT OF THE ATOMIC BOMB (VOL. I), AND DURING THE PERIOD FOLLOWING THE END OF WORLD WAR II UNTIL THE MANHATTAN DISTRICT RELINQUISHED CONTROL TO THE ATOMIC ENERGY COMMISSION AS OF JANUARY 1947 (VOL. II). ALTHOUGH SEC URITY REGULATIONS HAVE REQUIRED SOME DELETIONS IN THE ORIGINAL TEXT OF THE TWO VOLUMES, EVERY EFFORT HAS BEEN MADE TO RETAIN THE ORIGINAL LANGUGAGE AND EXPERSSIONS OF THE AUTHORS.

  19. Monte Carlo dose calculations and radiobiological modelling: analysis of the effect of the statistical noise of the dose distribution on the probability of tumour control.

    Science.gov (United States)

    Buffa, F M; Nahum, A E

    2000-10-01

    The aim of this work is to investigate the influence of the statistical fluctuations of Monte Carlo (MC) dose distributions on the dose volume histograms (DVHs) and radiobiological models, in particular the Poisson model for tumour control probability (tcp). The MC matrix is characterized by a mean dose in each scoring voxel, d, and a statistical error on the mean dose, sigma(d); whilst the quantities d and sigma(d) depend on many statistical and physical parameters, here we consider only their dependence on the phantom voxel size and the number of histories from the radiation source. Dose distributions from high-energy photon beams have been analysed. It has been found that the DVH broadens when increasing the statistical noise of the dose distribution, and the tcp calculation systematically underestimates the real tumour control value, defined here as the value of tumour control when the statistical error of the dose distribution tends to zero. When increasing the number of energy deposition events, either by increasing the voxel dimensions or increasing the number of histories from the source, the DVH broadening decreases and tcp converges to the 'correct' value. It is shown that the underestimation of the tcp due to the noise in the dose distribution depends on the degree of heterogeneity of the radiobiological parameters over the population; in particular this error decreases with increasing the biological heterogeneity, whereas it becomes significant in the hypothesis of a radiosensitivity assay for single patients, or for subgroups of patients. It has been found, for example, that when the voxel dimension is changed from a cube with sides of 0.5 cm to a cube with sides of 0.25 cm (with a fixed number of histories of 10(8) from the source), the systematic error in the tcp calculation is about 75% in the homogeneous hypothesis, and it decreases to a minimum value of about 15% in a case of high radiobiological heterogeneity. The possibility of using the error

  20. Research in radiobiology

    Energy Technology Data Exchange (ETDEWEB)

    Jee, W.S.S.

    1990-07-15

    This report discusses the technical progress made during the past year. Good progress has been made in the areas of bones cells at risk, bone cell morphometry, bone cell residence time, microdistribution of plutonium-239, and the calculation of cell-specific radiation dosimetry. 3 figs., 11 tabs. (KJD)

  1. VOL AR PLATING OF DISTAL RADIUS FRACTURE : A RETROSPECTIVE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Victor

    2015-06-01

    Full Text Available BACKGROUND: Treatment of distal radius has undergone remarkable changes since the time of Abraham colles. Conservative treatment with cast application has given way to operative techniques for better o utcome in high demand young individuals. Volar plating fo r distal end radius fractures is an effective technique which allows early mobilisation with re storation of r adial inclination , radial length , articular congruity and palmar tilt. MATERIALS AND METHODS: T his study was performed in chettinad hospital and research institute between January 2013 and M arch 2014. 24 patients with closed isolated distal end radius fractures treated with open reduction and internal fixation with plates and screws by volar approach were followed up retrospectively for a minimum period of one year . There were 17 men and 7 women. Mean age was 44 years (Range, 22 - 75 years. The fractures were classified based on the AO system. There were 4 A2, 12 B3, 5 C1, 3 C2 fracture types. RESULTS : All the patients were evaluated with standard anteroposterior and lateral radiographs and CT scans in c ase of intraarticular fractures . In all patie nts plating of distal end radius done by volar approach. Patients were followed postoperatively for one y ear radiologically and clinically by modified clinical scoring system by Green and O Brien. Five patients had excellent results, thirteen patients had good results with twenty five percent restriction of wrist function . Five patients had fair results. One patient had postop wound infection which required implant removal and external fixator application . CONCLUSION: With proper patient selection a nd accurate surgical techniques , volar plating continues to be a useful method of treatment for distal end radius fractures with minimal complications and allowing early return of patients to normal activities.

  2. Baltische Musik für Streichorchester (Vol. 2) / Hans-Christian Dadelsen

    Index Scriptorium Estoniae

    Dadelsen, Hans-Christian

    1995-01-01

    Uuest heliplaadist "Baltische Musik für Streichorchester (Vol. 2). Ostrobothnian Chamber Orchestra, Juha Kangas". Finlandia/East West Records CD 4509-9789-2 (WD: 64'34") Plaadil ka Erkki-Sven Tüüri teos "Insula Deserta"

  3. Book review: Vetter, H. 2005. Terralog. Turtles of the World. Vol. 3. Central and South America

    Directory of Open Access Journals (Sweden)

    2006-12-01

    Full Text Available Book review: Vetter, H. 2005. Terralog. Turtles of the World. Vol. 3. Central and South America/Schildkröten der Welt Band 3. Mittel- und Südamerika: 1-128, color pictures 606 + 9. Edition Chimaira, Frankfurt, Germany.ISBN 3-930612-82-8; 29.7 x 20.8 cm

  4. Dosimetric and radiobiological comparison of CyberKnife M6TM InCise multileaf collimator over IRISTM variable collimator in prostate stereotactic body radiation therapy

    Directory of Open Access Journals (Sweden)

    Vindu Kathriarachchi

    2016-01-01

    Full Text Available The impetus behind our study was to establish a quantitative comparison between the IRIS collimator and the InCise multileaf collimator (MLC (Accuray Inc. Synnyvale, CA for prostate stereotactic body radiation therapy (SBRT. Treatment plans for ten prostate cancer patients were performed on MultiPlan™ 5.1.2 treatment planning system utilizing MLC and IRIS for 36.25 Gy in five fractions. To reduce the magnitude of variations between cases, the planning tumor volume (PTV was defined and outlined for treating prostate gland only, assuming no seminal vesicle or ex-capsule involvement. Evaluation indices of each plan include PTV coverage, conformity index (CI, Paddick's new CI, homogeneity index, and gradient index. Organ at risk (OAR dose sparing was analyzed by the bladder wall Dmaxand V37Gy, rectum Dmaxand V36Gy. The radiobiological response was evaluated by tumor control probability and normal tissue complication probability based on equivalent uniform dose. The dose delivery efficiency was evaluated on the basis of planned monitor units (MUs and the reported treatment time per fraction. Statistical significance was tested using the Wilcoxon signed rank test. The studies indicated that CyberKnife M6™ IRIS and InCise™ MLC produce equivalent SBRT prostate treatment plans in terms of dosimetry, radiobiology, and OAR sparing, except that the MLC plans offer improvement of the dose fall-off gradient by 29% over IRIS. The main advantage of replacing the IRIS collimator with MLC is the improved efficiency, determined from the reduction of MUs by 42%, and a 36% faster delivery time.

  5. Dosimetry and radiobiology at the new RA-3 reactor boron neutron capture therapy (BNCT) facility: application to the treatment of experimental oral cancer.

    Science.gov (United States)

    Pozzi, E; Nigg, D W; Miller, M; Thorp, S I; Heber, E M; Zarza, L; Estryk, G; Monti Hughes, A; Molinari, A J; Garabalino, M; Itoiz, M E; Aromando, R F; Quintana, J; Trivillin, V A; Schwint, A E

    2009-07-01

    The National Atomic Energy Commission of Argentina (CNEA) constructed a novel thermal neutron source for use in boron neutron capture therapy (BNCT) applications at the RA-3 research reactor facility located in Buenos Aires. The aim of the present study was to perform a dosimetric characterization of the facility and undertake radiobiological studies of BNCT in an experimental model of oral cancer in the hamster cheek pouch. The free-field thermal flux was 7.1 x 10(9) n cm(-2)s(-1) and the fast neutron flux was 2.5 x 10(6) n cm(-2)s(-1), indicating a very well-thermalized neutron field with negligible fast neutron dose. For radiobiological studies it was necessary to shield the body of the hamster from the neutron flux while exposing the everted cheek pouch bearing the tumors. To that end we developed a lithium (enriched to 95% in (6)Li) carbonate enclosure. Groups of tumor-bearing hamsters were submitted to BPA-BNCT, GB-10-BNCT, (GB-10+BPA)-BNCT or beam only treatments. Normal (non-cancerized) hamsters were treated similarly to evaluate normal tissue radiotoxicity. The total physical dose delivered to tumor with the BNCT treatments ranged from 6 to 8.5 Gy. Tumor control at 30 days ranged from 73% to 85%, with no normal tissue radiotoxicity. Significant but reversible mucositis in precancerous tissue surrounding tumors was associated to BPA-BNCT. The therapeutic success of different BNCT protocols in treating experimental oral cancer at this novel facility was unequivocally demonstrated.

  6. Ion beam therapy fundamentals, technology, clinical applications

    CERN Document Server

    2012-01-01

    The book provides a detailed, up-to-date account of the basics, the technology, and the clinical use of ion beams for radiation therapy. Theoretical background, technical components, and patient treatment schemes are delineated by the leading experts that helped to develop this field from a research niche to its current highly sophisticated and powerful clinical treatment level used to the benefit of cancer patients worldwide. Rather than being a side-by-side collection of articles, this book consists of related chapters. It is a common achievement by 76 experts from around the world. Their expertise reflects the diversity of the field with radiation therapy, medical and accelerator physics, radiobiology, computer science, engineering, and health economics. The book addresses a similarly broad audience ranging from professionals that need to know more about this novel treatment modality or consider to enter the field of ion beam therapy as a researcher. However, it is also written for the interested public an...

  7. A Review of Soviet Studies in the Psychology of Learning and Teaching Mathematics (6 Volumes). Proceedings of the National Academy of Education, Vol. 4, 1977.

    Science.gov (United States)

    van Bruggen, Johan C.; Freudenthal, Hans

    The English translations of the first six volumes of Studies on the Teaching and Learning of Mathematics in the Soviet Union are viewed in this document. The contents of each volume are briefly described: vol. 1, The Learning of Mathematical Concepts; vol. 2, The Structure of Mathematical Abilities; vol. 3, Problem Solving in Arithmetic and…

  8. Commande boucle fermée multivariable pour le vol en formation de vaisseaux spatiaux

    OpenAIRE

    Gaulocher, Sebastian

    2007-01-01

    Cette thèse traite du contrôle du vol en formation de vaisseaux spatiaux. Le vol en formation permet de réaliser de nouveaux scénarios de missions. De par la diversité des applications envisageables, les travaux sont divisés en deux parties. Dans la première partie, restreinte au contrôle des centres de masse des vaisseaux, une approche est proposée pour modéliser les orbites relatives entre deux satellites en orbite terrestre, tenant compte de l'aplatissement de la Terre. Fondée sur le scéna...

  9. Efecto del aceite de sacha inchi (plukenetia volúbilis l sobre el perfil lipídico en pacientes con hiperlipoproteinemia Effect of sacha inchi oil (plukenetia volúbilis l on the lipid profile of patients with hyperlipoproteinemia

    Directory of Open Access Journals (Sweden)

    Fausto Garmendia

    2011-12-01

    Full Text Available El presente es un trabajo experimental piloto, abierto, para conocer el efecto, dosis efectiva y efectos secundarios del aceite de sacha inchi (Plukenetia volúbilis L en el perfil lipídico de pacientes con hipercolesterolemia; para ello, se incluyó a 24 pacientes de 35 a 75 años, en quienes se determinó los valores sanguíneos de colesterol total (CT, HDL, triglicéridos (Tg, glucosa, ácidos grasos no esterificados (AGNE e insulina Se aleatorizó a los participantes para recibir 5 mL o 10 mL de una suspensión conteniendo 2gr/5ml de aceite de sacha inchi, durante cuatro meses. La ingesta del aceite produjo caída en los valores promedio del CT, y AGNE con elevación del c-HDL en ambos grupos. La dosis de 10 mL se asoció a mayores niveles de insulina en el grupo aleatorizado a recibir 10 ml. El aceite de sacha inchi parece tener efectos benéficos sobre el perfil lipídico en pacientes con dislipidemia, requiriéndose la evaluación de su eficacia y seguridad en ensayos clínicos aleatorizados.We performed a pilot, experimental, open study in order to know the effect, effective dosage and secondary effects of sacha inchi´s (Plukenetia volúbilis L oil on the lipid profiles of patients with hypercholesterolemia. We included 24 patients of ages 35 to 75, to whom we measured total cholesterol (TC, HDL, triglycerides (Tg, glucose (G, non-esterified fatty acids (NEFA and insulin (I levels in blood, then we randomized them to receive sacha inchi oil orally 5 ml or 10 ml of a suspension of sacha inchi oil (2gr/5ml for four months. The oil intake produced a decrease in the mean values of TC, and NEFA, and a rise in HDL in both subgroups. The subgroup receiving 10 ml was associated to an increase in the insulin levels. Sacha inchi oil appears to have beneficial effects on the lipid profile of patients with dyslipidemia, but their efficacy and security should be evaluated in randomized clinical trials.

  10. Correction: Cocaine cardiomyopathy: A case report (2014, vol. 9, no. 3, pp. 233-237)

    OpenAIRE

    Georgijev Antonio; Zhivadinovic Julija

    2016-01-01

    In Sanamed Medical Journal, vol. 9, issue 3, in the text titled 'COCAINE CARDIOMYOPATHY-A CASE REPORT' authors made a mistake by inadequately citing parts of scientific paper, in sections Introduction and Discussion. The mistake was discovered by Center for Evaluation in Education and Science (CEON). Authors were informed from the Editorial Board of Medical Journal 'Sanamed' and the stated parts of paper were timely corrected.

  11. Substâncias voláteis em mel floral e mel de melato

    Directory of Open Access Journals (Sweden)

    CAMPOS Gisélia

    2000-01-01

    Full Text Available Embora pareça existir um "flavor" característico de mel, a grande variedade de flores disponíveis para a abelha, possibilita uma grande diversidade de flavor e aroma, indicando a presença de vários componentes voláteis. Alguns destes dependem da fisiologia da abelha, dos procedimentos após a colheita e no mel de melato há também a interferência de insetos sugadores e das formigas. Várias substâncias voláteis já foram identificadas, sendo algumas características de determinados méis uniflorais. Com o objetivo de encontrar uma substância volátil característica do mel de melato, seis amostras deste tipo de mel e seis amostras de mel floral foram analisadas usando extração por arraste de gás hidrogênio e cromatografia a gás acoplada a espectrometria de massas. Ácido acético foi encontrado em quatro amostras de mel de melato e em uma amostra de mel floral porém, com menor abundância.

  12. Radioembolization of hepatocarcinoma with {sup 90}Y glass microspheres: development of an individualized treatment planning strategy based on dosimetry and radiobiology

    Energy Technology Data Exchange (ETDEWEB)

    Chiesa, C.; Maccauro, M.; Aliberti, G.; Padovano, B.; Seregni, E.; Crippa, F. [Foundation IRCCS Istituto Nazionale Tumori, Nuclear Medicine Division, Milan (Italy); Mira, M.; Negri, A. [University of Milan, Postgraduate Health Physics School, Milan (Italy); Spreafico, C.; Morosi, C.; Civelli, E.; Lanocita, R.; Marchiano, A. [Foundation IRCCS Istituto Nazionale Tumori, Radiology 2, Milan (Italy); Romito, R.; Sposito, C.; Bhoori, S.; Facciorusso, A.; Mazzaferro, V. [Foundation IRCCS Istituto Nazionale Tumori, Surgery 1, Milan (Italy); Camerini, T. [Foundation IRCCS Istituto Nazionale Tumori, Scientific Direction, Milan (Italy); Carrara, M. [Foundation IRCCS Istituto Nazionale Tumori, Health Physics, Milan (Italy); Pellizzari, S. [University La Sapienza, Engineering Faculty, Rome (Italy); Migliorisi, M. [Foundation IRCCS Istituto Nazionale Tumori, Nuclear Medicine Division, Milan (Italy); Foundation IRCCS Istituto Nazionale Tumori, Clinical Engineering, Milan (Italy); De Nile, M.C. [University of Pavia, Physics Faculty, Pavia, Lombardy (Italy)

    2015-10-15

    The aim of this study was to optimize the dosimetric approach and to review the absorbed doses delivered, taking into account radiobiology, in order to identify the optimal methodology for an individualized treatment planning strategy based on {sup 99m}Tc-macroaggregated albumin (MAA) single photon emission computed tomography (SPECT) images. We performed retrospective dosimetry of the standard TheraSphere registered treatment on 52 intermediate (n = 17) and advanced (i.e. portal vein thrombosis, n = 35) hepatocarcinoma patients with tumour burden < 50 % and without obstruction of the main portal vein trunk. Response was monitored with the densitometric radiological criterion (European Association for the Study of the Liver) and treatment-related liver decompensation was defined ad hoc with a time cut-off of 6 months. Adverse events clearly attributable to disease progression or other causes were not attributed to treatment. Voxel dosimetry was performed with the local deposition method on {sup 99m}Tc-MAA SPECT images. The reconstruction protocol was optimized. Concordance of {sup 99m}Tc-MAA and {sup 90}Y bremsstrahlung microsphere biodistributions was studied in 35 sequential patients. Two segmentation methods were used, based on SPECT alone (home-made code) or on coregistered SPECT/CT images (IMALYTICS trademark by Philips). STRATOS trademark absorbed dose calculation was validated for {sup 90}Y with a single time point. Radiobiology was used introducing other dosimetric variables besides the mean absorbed dose D: equivalent uniform dose (EUD), biologically effective dose averaged over voxel values (BED{sub ave}) and equivalent uniform biologically effective dose (EUBED). Two sets of radiobiological parameters, the first derived from microsphere irradiation and the second from external beam radiotherapy (EBRT), were used. A total of 16 possible methodologies were compared. Tumour control probability (TCP) and normal tissue complication probability (NTCP) were

  13. SU-C-BRE-05: PTV Margin Determination Based On Tumor Radiobiological Characteristics and Geometric Uncertainties Derived From Daily Cone- Beam CT Images

    Energy Technology Data Exchange (ETDEWEB)

    Selvaraj, J [Inlaks and Budhrani Hospital (India)

    2014-06-15

    Purpose: To determine required PTV margins for ≤1% loss in mean population TCP using systematic (Σ) and random (σ) errors calculated from daily cone-beam CT (CBCT) images of head and neck patients. Methods: Daily CBCT images were acquired for 50 head and neck patients. The CBCT image sets acquired at each fraction were registered with planning CT to obtain positional errors for each patient for each fraction. Systematic and random errors were calculated from data collected for 50 patients as described in IPEM On Target report. CTV delineation uncertainty of 2mm is added quadratically to systematic error. Assuming a spherical target volume, the dose in each voxel of target volume is summed for each fraction in the treatment by shifting the dose grid to calculate mean population TCP inclusive of geometric uncertainties using a Monte Carlo method. These simulations were repeated for the set of Σ and σ in each axis for different PTV margins and drop in TCP for each margin are obtained. In order to study the effect of dose-response curve on PTV margins, two different σα of 0.048 Gy-1 and 0.218 Gy-1 representing steep and shallow dose-response curves are studied. Σ were 2.5, 2.5, 2.1 mm and σ were 0.3, 0.3 0.2 mm respectively in x, y and z axis respectively. Results: PTV margins based on tumor radiobiological characteristics are 4.8, 4.8 and 4 mm in x, y and z axis assuming 25 treatment fractions for σα 0.048 Gy-1 (steep) and 4.2,4.2 and 2.2 for σα of 0.218 Gy-1 (shallow). While the TCP-based margins did not differ much in x and y axis, it is considerably smaller in z axis for shallow DRC. Conclusion: TCP based margins are substantially smaller than physical dose-based margin recipes. This study also demonstrates the importance of considering tumor radiobiological characteristics while deriving margins.

  14. Vol. 385

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    A Comparative Study of Family Migi'ation in Floating Population Between the Generations -80' s and Post-80' s Shao Cen & Zhang Before Yi(1) Abstract: Based on the data of "Nationwide Dynamic Monitoring of Floating Population in the Second Half of 2010", the difference of family migration behavior between two generations of floating population--be- fore - 80' s and post - 80' s is discussed under the analytical framework of Classical Migration Theory and NELM in this paper. The study has found that the significant intergenerational differences exist in educa- tion levels and employment, which exerts significant influence on family migration behavior. On the other side, there is no significant difference in influential factors on family migration as residence time, the fam- ily income in immigrant city, remittance between two generations of floating population, in which the in- tergenerational consistency is noticeable. Key Words:Floating Population Intergenerational Difference Family Migration

  15. Wooden windows and doors. Vol. 2. Construction, connections, surfaces, energy conservation; Holzfenster und -tueren. Bd. 2. Konstruktion, Anschluesse, Oberflaechen, Energieeinsparung

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, Ulrich; Huckfeldt, Tobias; Wenk, Hans-Joachim (eds.)

    2012-07-01

    Vol. II supplements and complements Vol. I with much additional information. While Vol. I focused exclusively on wooden windows, Vol. II goes into wooden doors, frames, connections, armature technology, folding and rolling shutters, skylights, wooden replacement parts, replacement parts made of other materials, and energy conservation. Other subjects like armatures, glazing, damage, repair, restoration, maintenance and regulations are presented in more detail. [German] Als Band II ergaenzt und komplettiert das Buch den ersten Band ''Holzfenster'' mit zahlreichen flankierenden Themenbereichen. Waehrend sich Band I ausschliesslich auf Holzfenster konzentriert, erschliesst Band II neue Bereiche, wie Holztueren, Rahmenkonstruktionen, Anschluesse, Beschlagtechnik, Fenster- und Rolllaeden, Dachflaechenfenster, Vollholzergaenzungen, Holzersatzmaterialien oder Energieeinsparung. Weitere Themen, wie Beschlaege, Verglasungen, Schaeden, Sanierung, Restaurierung, Wartung und Regelwerke, werden vertieft und ergaenzt.

  16. Assessing the Value of an Optional Radiation Oncology Clinical Rotation During the Core Clerkships in Medical School

    Energy Technology Data Exchange (ETDEWEB)

    Zaorsky, Nicholas G.; Malatesta, Theresa M.; Den, Robert B.; Wuthrick, Evan; Ahn, Peter H.; Werner-Wasik, Maria; Shi, Wenyin; Dicker, Adam P.; Anne, P. Rani; Bar-Ad, Voichita [Department of Radiation Oncology, Jefferson Medical College, Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States); Showalter, Timothy N., E-mail: timothy.showalter@jeffersonhospital.org [Department of Radiation Oncology, Jefferson Medical College, Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States)

    2012-07-15

    Purpose: Few medical students are given proper clinical training in oncology, much less radiation oncology. We attempted to assess the value of adding a radiation oncology clinical rotation to the medical school curriculum. Methods and Materials: In July 2010, Jefferson Medical College began to offer a 3-week radiation oncology rotation as an elective course for third-year medical students during the core surgical clerkship. During 2010 to 2012, 52 medical students chose to enroll in this rotation. The rotation included outpatient clinics, inpatient consults, didactic sessions, and case-based presentations by the students. Tests of students' knowledge of radiation oncology were administered anonymously before and after the rotation to evaluate the educational effectiveness of the rotation. Students and radiation oncology faculty were given surveys to assess feedback about the rotation. Results: The students' prerotation test scores had an average of 64% (95% confidence interval [CI], 61-66%). The postrotation test scores improved to an average of 82% (95% CI, 80-83%; 18% absolute improvement). In examination question analysis, scores improved in clinical oncology from 63% to 79%, in radiobiology from 70% to 77%, and in medical physics from 62% to 88%. Improvements in all sections but radiobiology were statistically significant. Students rated the usefulness of the rotation as 8.1 (scale 1-9; 95% CI, 7.3-9.0), their understanding of radiation oncology as a result of the rotation as 8.8 (95% CI, 8.5-9.1), and their recommendation of the rotation to a classmate as 8.2 (95% CI, 7.6-9.0). Conclusions: Integrating a radiation oncology clinical rotation into the medical school curriculum improves student knowledge of radiation oncology, including aspects of clinical oncology, radiobiology, and medical physics. The rotation is appreciated by both students and faculty.

  17. Expansão volêmica em raquianestesia para cesariana. Como realizá-la?

    Directory of Open Access Journals (Sweden)

    Cardoso Mônica Maria Siaulys Capel

    2004-01-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Em pacientes não obstétricas, demonstrou-se que a expansão volêmica rápida realizada imediatamente após a injeção subaracnóidea do anestésico local era mais efetiva que a expansão volêmica lenta, realizada previamente à instalação do bloqueio para se reduzir a incidência e a gravidade da hipotensão arterial após raquianestesia. O objetivo do estudo foi comparar a incidência de hipotensão arterial e o consumo de vasopressores em gestantes submetidas à cesariana sob raquianestesia com diferentes regimes de expansão volêmica. MÉTODO: Foram avaliadas prospectivamente 60 gestantes de termo submetidas à cesariana sob raquianestesia. As pacientes receberam expansão volêmica com 10 ml.kg-1 de solução de Ringer com lactato como segue: Grupo 1 (n = 20, antes da raquianestesia através de cateter 18G; Grupo 2 (n = 20, após a raquianestesia e com cateter 18G e Grupo 3 (n = 20 após a raquianestesia com cateter 16G sob ação de pressurizador. A pressão arterial (PA foi monitorizada a cada minuto e administrou-se 0,2 mg de metaraminol para qualquer diminuição de PA, a partir do valor de controle e 0,4 mg para diminuição > 20%. A PA controle foi definida como a média de três valores sucessivos de pressão arterial sistólica obtidos antes da expansão volêmica e do bloqueio. Estudou-se a velocidade de infusão de fluidos, incidência de hipotensão arterial materna, náusea e vômito, consumo de metaraminol, índice de Apgar e pH da artéria umbilical. RESULTADOS: A velocidade de administração de fluidos foi maior no Grupo 3 do que nos Grupos 1 e 2 (201 ± 61 vs 56 ± 13 e 59 ± 21 ml.min-1, p < 0,05. Os grupos foram semelhantes em relação à incidência de hipotensão arterial, náusea, vômito, consumo de metaraminol, índice de Apgar e pH da artéria umbilical. CONCLUSÕES: A expansão volêmica, realizada antes ou após a instalação da raquianestesia, de maneira rápida ou lenta, n

  18. Expansão volêmica em raquianestesia para cesariana. Como realizá-la?

    Directory of Open Access Journals (Sweden)

    Mônica Maria Siaulys Capel Cardoso

    2004-02-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Em pacientes não obstétricas, demonstrou-se que a expansão volêmica rápida realizada imediatamente após a injeção subaracnóidea do anestésico local era mais efetiva que a expansão volêmica lenta, realizada previamente à instalação do bloqueio para se reduzir a incidência e a gravidade da hipotensão arterial após raquianestesia. O objetivo do estudo foi comparar a incidência de hipotensão arterial e o consumo de vasopressores em gestantes submetidas à cesariana sob raquianestesia com diferentes regimes de expansão volêmica. MÉTODO: Foram avaliadas prospectivamente 60 gestantes de termo submetidas à cesariana sob raquianestesia. As pacientes receberam expansão volêmica com 10 ml.kg-1 de solução de Ringer com lactato como segue: Grupo 1 (n = 20, antes da raquianestesia através de cateter 18G; Grupo 2 (n = 20, após a raquianestesia e com cateter 18G e Grupo 3 (n = 20 após a raquianestesia com cateter 16G sob ação de pressurizador. A pressão arterial (PA foi monitorizada a cada minuto e administrou-se 0,2 mg de metaraminol para qualquer diminuição de PA, a partir do valor de controle e 0,4 mg para diminuição > 20%. A PA controle foi definida como a média de três valores sucessivos de pressão arterial sistólica obtidos antes da expansão volêmica e do bloqueio. Estudou-se a velocidade de infusão de fluidos, incidência de hipotensão arterial materna, náusea e vômito, consumo de metaraminol, índice de Apgar e pH da artéria umbilical. RESULTADOS: A velocidade de administração de fluidos foi maior no Grupo 3 do que nos Grupos 1 e 2 (201 ± 61 vs 56 ± 13 e 59 ± 21 ml.min-1, p < 0,05. Os grupos foram semelhantes em relação à incidência de hipotensão arterial, náusea, vômito, consumo de metaraminol, índice de Apgar e pH da artéria umbilical. CONCLUSÕES: A expansão volêmica, realizada antes ou após a instalação da raquianestesia, de maneira rápida ou lenta, n

  19. 英文文摘%Logic in Vol. 4 of 'Das Kapital' : Cognitive Development Science

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    Abstract : The practical logic of Vol. 4 of ' Das Kapital' is the cognitive development mechanism of category of ' Das Kapital' In this sense, this logic makes the ' production' of categories practical, the dominant principle is that understanding is made of history. Historical part and theoretical part construct the general writing logic togeth-er, historical part sets up theoretical direction for research afterwards. The implications are of the following: (1) Based on ' organic growth' of historical productive mode, the core of the category is surplus value ; (2) From the movement of category production to disclose historical structural growth ; ( 3 ) Through the general ' production' of theories, it shows the internal integration between critique on methodology and critique on epistemology. Thus Vol. 4 of ' Das Kapital' rejected the wrong demand in ' History of the Theory of Surplus Value' edited by Kautsky. ' Das Kapital' integrated the logic of historical development and the logic of development in understanding, inte-grated historical method and categorical method, which sets an example in the methodology in political economy.%Abstract : The practical logic of Vol. 4 of ' Das Kapital' is the cognitive development mechanism of category of ' Das Kapital' In this sense, this logic makes the ' production' of categories practical, the dominant principle is that understanding is made of history. Historical part and theoretical part construct the general writing logic togeth-er, historical part sets up theoretical direction for research afterwards. The implications are of the following: (1) Based on ' organic growth' of historical productive mode, the core of the category is surplus value ; (2) From the movement of category production to disclose historical structural growth ; ( 3 ) Through the general ' production' of theories, it shows the internal integration between critique on methodology and critique on epistemology. Thus

  20. Reposição volêmica em pacientes politraumatizados

    Directory of Open Access Journals (Sweden)

    Delmo Sakabe

    2007-05-01

    Full Text Available O debate sobre a administração de colóides, cristalóides, soluções hipertônicas ou elementos sanguíneos em pacientes críticos estende-se desde o século 19. Algumas dessas soluções podem ser diferentemente distribuídas nos espaços intra e extravasculares, assim como nos espaços intra e extracelulares, causando diferentes efeitos fisiológicos. Diversos estudos foram realizados com o objetivo de comparar um fluido ao outro, mostrando a eficácia e as vantagens de cada um. Porém, não existe um trabalho que consiga provar uma diferença significativa em relação à morbi-mortalidade após a reposição volêmica com cada tipo de fluido. Esses estudo, por serem diferentes em relação aos protocolos de ressucitação, volumes e tipos de fluidos utilizados, dificultam a comparação dos resultados; no entanto, sabe-se que a reposição volêmica depende de cada situação clínica. A utilização da reposição volêmica pré-hospitalar é discutível, visto que pode aumentar o sangramento ou mesmo ser motivo de atraso na transferência do paciente ao hospital, ao mesmo tempo em que pode reduzir o risco de isquemia tecidual. Uma vez que a hemorragia tenha sido controlada, há um consenso para o fato de que o volume intravascular deve ser reposto da forma mais rápida e eficaz possível para minimizar a quantidade de células afetadas diretamente pela má perfusão tecidual. Os atuais trabalhos envolvidos nessa polêmica trazem resultados que sugerem a continuidade das investigações, visto que nenhum deles atingiu um ponto final comum. Desses estudos, um aspecto com o qual todos concordam e que se tornou claro é que não existe uma fórmula mágica única de administração intravenosa para os pacientes politraumatizados. Este trabalho visa, por meio de revisão bibliográfica, mostrar os tipos de fluidos a serem utilizados para reposição volêmica de pacientes politraumatizados, assim como os meios e a forma de utilização dos

  1. QSAR study and VolSurf characterization of anti-HIV quinolone library

    Science.gov (United States)

    Filipponi, Enrica; Cruciani, Gabriele; Tabarrini, Oriana; Cecchetti, Violetta; Fravolini, Arnaldo

    2001-03-01

    Antiviral quinolones are promising compounds in the search for new therapeutically effective agents for the treatment of AIDS. To rationalize the SAR for this new interesting class of anti-HIV derivatives, we performed a 3D-QSAR study on a library of 101 6-fluoro and 6-desfluoroquinolones, taken either from the literature or synthesized by us. The chemometric procedure involved a fully semiempirical minimization of the molecular structures by the AMSOL program, which takes into account the solvatation effect, and their 3D characterization by the VolSurf/GRID program. The QSAR analysis, based on PCA and PLS methods, shows the key structural features responsible for the antiviral activity.

  2. Patrones de evolución de filiales en entornos volátiles

    Directory of Open Access Journals (Sweden)

    Luis E. Sigala Paparella

    2010-01-01

    Full Text Available En este trabajo se aplican y se extienden los patrones de evolución de filiales planteados por Birkinshaw y Hood, al estudiar la influencia de los entornos volátiles sobre los procesos de evolución de las filiales de empresas multinacionales. Utilizando una metodología cualitativa a través de 41 estudios de casos de filiales de diversos sectores localizadas en Venezuela, se observó que las mismas siguen procesos conducentes a la mejora, el refuerzo y al declive de sus roles. En los resultados se identifican a la matriz y la propia filial como impulsores de esos procesos, pero se aprecia también al entorno local como determinante de la evolución de las filiales, con lo cual se extienden los patrones que plantean Birkinshaw y Hood que consideran sólo a la matriz y a la propia filial. Como conclusión, no sólo se resalta la importancia del entorno en la determinación del rol de las filiales, sino que se evidencia que los entornos volátiles pueden tener un impacto tanto positivo como negativo en la evolución de la filial.

  3. An elementary proof of MinVol(Rn = 0 for n > 3

    Directory of Open Access Journals (Sweden)

    Jiaqiang Mei

    2008-12-01

    Full Text Available In this paper, we give an elementary proof of the result that the minimal volumes of R³ and R4 are zero. The approach is to construct a sequence of explicit complete metrics on them such that the sectional curvatures are bounded in absolute value by 1 and the volumes tend to zero. As a direct consequence, we get that MinVol (Rn = 0 for n > 3.Neste artigo fornecemos uma demonstração elementar do resultado de que os volumes minimais de R³ e R4 são ambos iguais a zero. A abordagem consiste na construção de uma seqüência de métricas completas explícitas nesses espaços cujas curvaturas seccionais são limitadas em valor absoluto por 1 e os volumes tendem a zero. Como conseqüência direta, estabelecemos que MinVol(Rn = 0 para n > 3.

  4. MIRD Pamphlet No. 22 (Unabridged): Radiobiology and Dosimetry of alpha-Particle Emitters for Targeted Radionuclide Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sgouros, George; Roeske, John C.; McDevitt, Michael S.; Palm, Stig; Allen, Barry J.; Fisher, Darrell R.; Brill, Bertrand A.; Song, Hong; Howell, R. W.; Akabani, Gamal

    2010-02-28

    The potential of alpha-particle emitters to treat cancer has been recognized since the early 1900s. Advances in the targeted delivery of radionuclides, in radionuclide conjugation chemistry, and in the increased availability of alpha-emitters appropriate for clinical use have recently led to patient trials of alpha-particle-emitter labeled radiopharmaceuticals. Although alpha-emitters have been studied for many decades, their current use in humans for targeted therapy is an important milestone. The objective of this work is to review those aspects of the field that are pertinent to targeted alpha-particle-emitter therapy and to provide guidance and recommendations for human alpha-particle-emitter dosimetry.

  5. Radiotherapy for glioblastomas: from radiobiology to concomitant chemotherapy; Radiotherapie des glioblastomes: de la radiobiologie a la chimiotherapie concomitante

    Energy Technology Data Exchange (ETDEWEB)

    Simon, J.M.; Toubiana, T.; Lang, P.; Taillibert, S.; Mazeron, J.J. [Groupe Hospitalier Pitie-Salpetriere, Assistance Publique-Hopitaux de Paris, Service d' Oncologie Radiotherapique, 75 - Paris (France); Taillibert, S. [Groupe Hospitalier Pitie-Salpetriere, Assistance Publique-Hopitaux de Paris, Federation de Neurologie Mazarin, 75 - Paris (France)

    2005-09-15

    Primary signet ring cell carcinoma of urinary bladder is a rare tumor; accounting for approximately 0,24% of all bladder malignancies. In this study, we report a case of a 58-year old man who consulted for complaints of gross hematuria, the bladder biopsied showed signet ring cell carcinoma; the exploration of gastrointestinal tract did not reveal any other tumor localizations. A total cysto-prostatectomy was performed followed by radiotherapy. The aim of this study is to determine the anatomo-clinical, therapy and evolution characteristics of this rare tumor. (authors)

  6. Comparison of cytogenetic effects in bone marrow of mice after the flight on the biosatellite "BION-M1" and the ground-based radiobiological experiment

    Science.gov (United States)

    Dorozhkina, Olga; Vorozhtsova, Svetlana; Ivanov, Alexander

    2016-07-01

    During space flight, the astronauts are exposed to radiation exposure at low doses with low dose rates, so one of the actual areas of Radiobiology is research of action of ionizing radiation in low and ultra-low doses. Violation of the chromosome apparatus of living biosystems, ranging from viruses and bacteria to humans, is the most reliable evidence of exposure to ionizing radiation. In this regard, the study of cytogenetic damage in the cells of humans and animals is central to space radiobiology (Fedorenko B.S., 2006). In experiment "BION - M1" by anaphase method was determined level of chromosomal aberrations in bone marrow cells of tibia of mice. Flight duration biosatellite "BION - M1" (Sychev V.N. et al., 2014) was 30 days in Earth orbit. Euthanasia of experimental animals was carried out after 12 hours from the moment of landing satellite by method of cervical dislocation. The level of chromosomal aberrations in vivarium-housed control mice was 1,75 ± 0,6% and 1,8 ± 0,45%, while the mitotic index 1,46 ± 0,09% and 1,53 ± 0,05%. The content of animals in the experiment with onboard equipment led to some increase in aberrant mitosis (2,3 ± 0,4%) and reduction of the mitotic index (1,37 ± 0,02%). In the flight experiment "BION-M1" was a statistically significant increase in level of chromosome aberrations (29,7 ± 4,18%) and a decrease in the mitotic index (0,74 ± 0,07%). According to VA Shurshakova (2014), the radiation dose to mice ranged from 32 to 72 mGy and relate to a range of small doses (ICRP, 2012). In this connection we conducted a series of experiments in the ground conditions, the aim of which was the study of earliest effects of ionizing radiation in vivo in mice irradiated with low doses of γ-irradiation of 10 to 200 mGy in the first 24 hours after exposure, i.e. within the first post-radiation exposure cell cycle. Studies were carried out on adult female mice outbred ICR (CD-1) - SPF category at the age of 4-4.5 months with an average

  7. The in vivo study on the radiobiologic effect of prolonged delivery time to tumor control in C57BL mice implanted with Lewis lung cancer

    Directory of Open Access Journals (Sweden)

    Zhu Guo-Pei

    2011-01-01

    Full Text Available Abstract Background High-precision radiation therapy techniques such as IMRT or sterotactic radiosurgery, delivers more complex treatment fields than conventional techniques. The increased complexity causes longer dose delivery times for each fraction. The purpose of this work is to explore the radiobiologic effect of prolonged fraction delivery time on tumor response and survival in vivo. Methods 1-cm-diameter Lewis lung cancer tumors growing in the legs of C57BL mice were used. To evaluate effect of dose delivery prolongation, 18 Gy was divided into different subfractions. 48 mice were randomized into 6 groups: the normal control group, the single fraction with 18 Gy group, the two subfractions with 30 min interval group, the seven subfractions with 5 min interval group, the two subfractions with 60 min interval group and the seven subfractions with 10 min interval group. The tumor growth tendency, the tumor growth delay and the mice survival time were analyzed. Results The tumor growth delay of groups with prolonged delivery time was shorter than the group with single fraction of 18 Gy (P 0.05. Compared to the group with single fraction of 18 Gy, the groups with prolonged delivery time shorten the mice survival time while there was no significant difference between the groups with prolonged delivery time 30 min and the groups with prolonged delivery time 60 min. Conclusions The prolonged delivery time with same radiation dose shorten the tumor growth delay and survival time in the mice implanted with Lewis lung cancer. The anti-tumor effect decreased with elongation of the total interfractional time.

  8. Multiple sclerosis brain lesion measurements in clinical practice

    OpenAIRE

    2014-01-01

    Jain S., Smeets D., Sima D., Van Hecke W., Loeckx D., Van Huffel S., Maes F., ''Multiple sclerosis brain lesion measurements in clinical practice'', European journal of neurology, vol. 21 suppl. s1, pp. 345, 2014 (Joint congress of European neurology, May 31 - June 3, 2014, Istanbul, Turkey).

  9. Les objets sous contrainte. Gages, saisies, confiscations, vols,pillages, recel au Moyen Âge

    Directory of Open Access Journals (Sweden)

    Laurent Feller

    2010-10-01

    Full Text Available Du jeudi 20 au samedi 21 novembre 2009, à l’initiative d’Ana Rodriguez et de Laurent Feller, s’est tenu à Auxerre, dans la maison du Coche d’Eau, un séminaire d’études international portant sur Les objets sous contrainte. Gages, saisies, confiscation, vol, pillage, recel au Moyen Âge. Organisée conjointement par le Lamop, l’université de Paris 1 et le CCHS (CSIC de Madrid, partiellement financée par un projet Picasso de l’association Égide, l’opération a bénéficié du soutien de l’université ...

  10. Antjie Krog se vertaling van Henk van Woerden se roman Een mond vol glas

    Directory of Open Access Journals (Sweden)

    H.P. van Coller

    2002-08-01

    Full Text Available Antjie Krog’s translation of Henk van Woerden’s novel Een mond vol glas (A mouth full of glass Against a historical backdrop several critical approaches to translational theory are explicated. Traditional criticism seems to imply positioning between the Source Text (ST and the Target Text (TT. A functionalist approach (as propagated among others by Snell-Hornby, Nord and Naaijkens is a descriptive rather than a normative approach that focuses almost exclusively on the ST. This approach is consequently adopted in the evaluation of Krog’s translation; yet even within this more relativistic paradigm, a comparison between ST and TT should not be evaded. In the case of Krog’s translation, this comparison leads to the identification of scores of lexical, grammatical and stylistic errors.

  11. 养成记Vol.2初步入选的十人公布

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    受到众多读者喜爱的“Shiningstar养成记“在经历了三个月的报名后,最终有十位美眉通过了“海选”,即将等待由专业团队组成的审核小组进行第二轮淘汰。Vol.2的“养成记”正在紧张地筹划着全新操作方式,最后入选的美眉除了接受改造出现在杂志上以外,更有机会参与到现场活动中去!

  12. Neeme Järvi. "The Early Recordings", vol. 1 a 6. / Hulot, Jean-Claude

    Index Scriptorium Estoniae

    Hulot, Jean-Claude

    1998-01-01

    Uuest heliplaadist "Neeme Järvi. "The Early Recordings", vol. 1 a 6. Paganini: Concerto pour violon no. 1; Tchaikovski: Concerto pour violon op. 35; Concerto pour piano no. 1; Saint-Saens: Concerto pour piano no. 2; Beethoven: Concerto pour piano no. 4; R. Strauss: Till Eulenspiegels lustige Streiche. Don Juan; Cherubini: Requiem en re mineur; Chostakovitch: Fidelite, 8 ballades pour choeur d'hommes op. 136; Haydn: Concerto pour violoncelle no. 2; Tchaikovski: Variations Rococo. Pezzo capriccioso. Andante cantabile. Nocturne. Choeur d'hommes Academique de l'Etat d'Estonie, Orchestre Philharmonique de Moscou, Orchestre Symphonique d'URSS, Grand Orchestre Symphonique de la Radio d'URSS, Orchestre Symphonique de la Radio d'Estonie, Gustav Ernesaks, Neeme Järvi. Melodiya 74 321 40 719-2 a 40 724-2, distribution BMG (6 CD:96 F chacun)

  13. Componentes volátiles de la gulupa passiflora maliformís

    Directory of Open Access Journals (Sweden)

    P. Restrepo

    2009-07-01

    Full Text Available QLos componentes volátiles del aroma de la gulupa fueron extraídos mediante el método de destilación-extracción simultánea utilizando diciorometano como solvente orgánico y concentrándolo hasta obtener 0,2 ml. El extracto analizado por CG y CG-EM muestra que el aroma de la gulupa está constituido por 43 componentes 6 mayoritarios y 34 de menor concentración, de los cuales fueron totalmente identificados 32 (el 97,78% del total del aroma y no se pudieron identificar 8 (el 2,22% del aroma. Los componentes mayoritarios encontrados en al aroma da la gulupa son: el butanoato de etilo, el butanoato de metilo, el 2-butenoato de metilo, los hexanoatos de metilo y etilo, y el 2-hexanol.

  14. Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDI{sub vol})

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Cederlund, Kerstin; Aspelin, Peter; Brismar, Torkel B. [Intervention and Technology at Karolinska Institutet, Department of Clinical Science, Division of Medical Imaging and Technology, Stockholm (Sweden); Karolinska University Hospital in Huddinge, Department of Radiology, Stockholm (Sweden); Bjoerk, Jonas [FoU-centrum Skaane Skaanes Universitetssjukhus i Lund, Lund (Sweden); Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Lasarettet Trelleborg, Trelleborg (Sweden)

    2014-08-15

    To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index (CTDI{sub vol}) and body weight (BW). One hundred patients referred for standard three-phase thoraco-abdominal MDCT examination were enrolled. BW was measured in the CT suite. Forty grams of iodine was administered intravenously (iodixanol 320 mg I/ml at 5 ml/s or iomeprol 400 mg I/ml at 4 ml/s) followed by a 50-ml saline flush. CTDI{sub vol} presented by the CT equipment during the parenchymal examination was recorded. The CM enhancement of the liver was defined as the attenuation HU of the liver parenchyma during the hepatic parenchymal phase minus the attenuation in the native phase. Liver parenchymal enhancement was negatively correlated to both CTDI{sub vol} (r = -0.60) and BW (r = -0.64), but the difference in correlation between those two was not significant. CTDI{sub vol} may replace BW when adjusting CM doses to body size. This makes it potentially feasible to automatically individualize CM dosage by CT. (orig.)

  15. JPRS Report, Science & Technology, USSR: Space Biology & Aerospace Medicine, Vol. 21, No. 6, November-December 1987.

    Science.gov (United States)

    1988-03-11

    SPACE BIOLOGY & AEROSPACE MEDICINE VOL 21, No 6, NOVEMBER-DECEMBER 1987 [Translation of the Russian- language bimonthly journal KOSMICHESKAYA BIOLOGIYA...and ontogenetic formation of orthograde walking in hominids [4, 5]. However, these sparse paleontological data enable us to reconstruct only in the

  16. SU-E-T-69: A Radiobiological Investigation of Dose Escalation in Lower Oesophageal Tumours with a Focus On Gastric Toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Carrington, R [Cardiff University, Cardiff, Wales (United Kingdom); Staffurth, J; Spezi, E; Crosby, T [Velindre Cancer Centre, Cardiff, Wales (United Kingdom); Warren, S; Partridge, M; Hawkins, M [CRUK/MRC Oxford Institute for Radiation Oncology, Oxford (United Kingdom); Gwynne, S [Singleton Hospital, Swansea, Wales (United Kingdom)

    2015-06-15

    The incidence of lower third oesophageal tumours is increasing in most Western populations. With the role of radiotherapy dose escalation being identified as a research priority in improving outcomes, it is important to quantify the increased toxicity that this may pose to sites such as the lower oesophagus. This study therefore aims to investigate the feasibility of lower oesophageal dose escalation with a focus on stomach tissue toxicity.The original 3D-conformal plans (50Gy3D) from 10 patients in the SCOPE1 trial were reviewed and compared to two RapidArc plans created retrospectively to represent the treatment arms of the forthcoming SCOPE2 trial: 50GyRA and 60GyRA (50Gy to PTV1 with a simultaneously integrated boost of 60Gy to PTV2). The stomach was contoured as stomach wall and dose constraints set according to QUANTEC. Normal tissue complication probability (NTCP) was estimated for the stomach wall for an endpoint of gastric bleeding. There was a mean increase of 5.93% in NTCP from 50Gy3D to 60GyRA and a mean increase of 8.15% in NTCP from the 50GyRA to 60GyRA. With NTCP modelling restricted to volumes outside PTV2, there was a mean decrease of 0.92% in NTCP from the 50Gy3D to 60GyRA, and a mean increase of 2.25% from 50GyRA to 60GyRA. There was a strong correlation between the NTCP and Stomach Wall/PTV1 overlap volume for all plans (R=0.80, 0.77 and 0.77 for 60GyRA, 50GyRA and 50Gy3D respectively). There was also a strong correlation between NTCP and the Stomach Wall/PTV2 overlap volume for 60GyRA (R= 0.82).Radiobiological modelling suggests that increasing the prescribed dose to 60Gy may be associated with a significantly increased risk of toxicity to the stomach within the boost volume. It is recommended that stomach toxicity be closely monitored prospectively when treating patients with lower oesophageal tumours in the forthcoming SCOPE 2 trial. Rhys Carrington received a PhD studentship grant from Cancer Research Wales. Grant number: 2445; Dr Warren and

  17. Análisis de los compuestos volátiles de la ciruela amarilla (Prunus domestica L. ssp. domestica

    Directory of Open Access Journals (Sweden)

    Yineth Ruiz

    2011-06-01

    Full Text Available El aroma de las frutas se debe a los constituyentes volátiles presentes que, aunque se encuentran en muy bajas concentraciones, contribuyen al aroma global en grados muy diversos. Se hace necesario usar técnicas de aislamiento y concentración que garanticen el análisis de una composición química semejante a la de la fruta. Este trabajo tuvo como objetivo el análisis de los compuestos volátiles de la ciruela amarilla (Prunus domestica L. ssp.domestica por el método de evaporación del aroma asistida por solvente (SAFE. Este método utiliza un equipo de destilación conectado a una bomba de alto vacío que ofrece la posibilidad de aislar rápidamente compuestos volátiles sin daño térmico en diferentes matrices alimentarias. La separación e identificación de los compuestos volátiles se realizó por cromatografía de gases-espectrometría de masas (GC-MS. Se identificaron 47 compuestos (6,55 mg/kg de pulpa de fruta, entre ellos 14 alcoholes, 8 aldehídos, 7 ésteres, 5 cetonas, 4 ácidos carboxílicos, 4 hidrocarburos aromáticos, 3 lactonas, un compuesto azufrado y una hidroxicetona; 16 de ellos se informan por primera vez. El acetato de etilo (2,88 mg/kg, etanol (1 mg/kg y ácido octanoico (0,78 mg/kg fueron los constituyentes volátiles mayoritarios de esta variedad de ciruela.

  18. Análisis de los compuestos volátiles de la ciruela amarilla (Prunus domestica L. ssp. domestica

    Directory of Open Access Journals (Sweden)

    Yineth Ruiz

    2011-01-01

    Full Text Available El aroma de las frutas se debe a los constituyentes volátiles presentes que, aunque se encuentran en muy bajas concentraciones, contribuyen al aroma global en grados muy diversos. Se hace necesario usar técnicas de aislamiento y concentración que garanticen el análisis de una composición química semejante a la de la fruta. Este trabajo tuvo como objetivo el análisis de los compuestos volátiles de la ciruela amarilla (Prunus domestica L. ssp. domestica por el método de evaporación del aroma asistida por solvente (SAFE. Este método utiliza un equipo de destilación conectado a una bomba de alto vacío que ofrece la posibilidad de aislar rápidamente compuestos volátiles sin daño térmico en diferentes matrices alimentarias. La separación e identificación de los compuestos volátiles se realizó por cromatografía de gases-espectrometría de masas (GC-MS. Se identificaron 47 compuestos (6,55 mg/kg de pulpa de fruta, entre ellos 14 alcoholes, 8 aldehídos, 7 ésteres, 5 cetonas, 4 ácidos carboxílicos, 4 hidrocarburos aromáticos, 3 lactonas, un compuesto azufrado y una hidroxicetona; 16 de ellos se informan por primera vez. El acetato de etilo (2,88 mg/kg, etanol (1 mg/kg y ácido octanoico (0,78 mg/kg fueron los constituyentes volátiles mayoritarios de esta variedad de ciruela.

  19. 'tomo_display' and 'vol_tools': IDL VM Packages for Tomography Data Reconstruction, Processing, and Visualization

    Science.gov (United States)

    Rivers, M. L.; Gualda, G. A.

    2009-05-01

    One of the challenges in tomography is the availability of suitable software for image processing and analysis in 3D. We present here 'tomo_display' and 'vol_tools', two packages created in IDL that enable reconstruction, processing, and visualization of tomographic data. They complement in many ways the capabilities offered by Blob3D (Ketcham 2005 - Geosphere, 1: 32-41, DOI: 10.1130/GES00001.1) and, in combination, allow users without programming knowledge to perform all steps necessary to obtain qualitative and quantitative information using tomographic data. The package 'tomo_display' was created and is maintained by Mark Rivers. It allows the user to: (1) preprocess and reconstruct parallel beam tomographic data, including removal of anomalous pixels, ring artifact reduction, and automated determination of the rotation center, (2) visualization of both raw and reconstructed data, either as individual frames, or as a series of sequential frames. The package 'vol_tools' consists of a series of small programs created and maintained by Guilherme Gualda to perform specific tasks not included in other packages. Existing modules include simple tools for cropping volumes, generating histograms of intensity, sample volume measurement (useful for porous samples like pumice), and computation of volume differences (for differential absorption tomography). The module 'vol_animate' can be used to generate 3D animations using rendered isosurfaces around objects. Both packages use the same NetCDF format '.volume' files created using code written by Mark Rivers. Currently, only 16-bit integer volumes are created and read by the packages, but floating point and 8-bit data can easily be stored in the NetCDF format as well. A simple GUI to convert sequences of tiffs into '.volume' files is available within 'vol_tools'. Both 'tomo_display' and 'vol_tools' include options to (1) generate onscreen output that allows for dynamic visualization in 3D, (2) save sequences of tiffs to disk

  20. Composite material in the Al 2 O3 -20 vol% YAG system

    Directory of Open Access Journals (Sweden)

    Radosław Lach

    2010-03-01

    Full Text Available Within alumina particle suspension yttria precursor was precipitated with ammonium carbonate. Drying and calcination at 600°C resulted in the mixture of alumina and yttria particles, the latter being much finer than alumina particles. This mixture was additionally homogenized by short attrition milling in aqueous suspension of pH selected on the basis of zeta (ζ potential measurements. It was found that acidic conditions (realized with HNO3 resulted in hard agglomerates. Such powder shows poor sintering ability. Much better properties showed powders homogenized under basic conditions. They give dense materials composed of YAG inclusions within alumina matrix. YAG particles resulted from the reaction of Y2O3 with Al2O3 during heat treatment. Homogenization of the system mixed at pH=8, corresponding to the heterofloculation conditions, is slightly better than observed at pH=10. YAG inclusions (20 vol% increase hardness and fracture toughness of the material in comparison with pure alumina polycrystals.

  1. Solidification of Magnesium (AM50A) / vol%. SiCp composite

    Science.gov (United States)

    Zhang, X.; Hu, H.

    2012-01-01

    Magnesium matrix composite is one of the advanced lightweight materials with high potential to be used in automotive and aircraft industries due to its low density and high specific mechanical properties. The magnesium composites can be fabricated by adding the reinforcements of fibers or/and particles. In the previous literature, extensive studies have been performed on the development of matrix grain structure of aluminum-based metal matrix composites. However, there is limited information available on the development of grain structure during the solidification of particulate-reinforced magnesium. In this work, a 5 vol.% SiCp particulate-reinforced magnesium (AM50A) matrix composite (AM50A/SiCp) was prepared by stir casting. The solidification behavior of the cast AM50A/SiCp composite was investigated by computer-based thermal analysis. Optical and scanning electron microscopies (SEM) were employed to examine the occurrence of nucleation and grain refinement involved. The results indicate that the addition of SiCp particulates leads to a finer grain structure in the composite compared with the matrix alloy. The refinement of grain structure should be attributed to both the heterogeneous nucleation and the restricted primary crystal growth.

  2. QSAR Study and VolSurf Characterization of Human Intestinal Absorption of Druge

    Institute of Scientific and Technical Information of China (English)

    胡桂香; 商志才; 等

    2003-01-01

    The prediction of human intestinal absorption is a major goal in the design,optimization,and selection of candidates for the develoment of oral drugs.In this study,a computerized method(VolSurf with GRID) was used as a novel tool for predicting human intestinal absorption of test compound,and for determining the critical molecular properties needed for human intestinal absorption.The tested molecules consisted of 20 diverse drug-like compounds.Partial least squares(PLS) discriminant analysis was used to correlate the experimental data with the theoretical molecular properties of human intestinal absorption.A good correlation(r2=0.95,q2=0.86) between the molecular modeling results and the experimental data demonstrated that human intestinal absorption could be predicted from the three-dimensional(3D) molecular structure of a compound .Favorable structureal properties identified for the potent intestinal absorption of drugs included strong imbalance between the center of mass of a molecule and the barycentre of its hydrophilic and hydrophobic regions and a definitive hydrophobic region as well as less hydrogen bonding donors and acceptors in the molecule.

  3. Radiobiological and genetic effects of Bromus inermis seed progeny from populations of the East-Ural Radioactive Trace (Russia, Kyshtym accident) - Radiobiological and genetic effects for Bromus inermis Leyss. Populations at the East-Ural radioactive trace (Russia, Kyshtym accident in 1957)

    Energy Technology Data Exchange (ETDEWEB)

    Antonova, Elena V.; Pozolotna, Vera N. [Institute of Plant and Animal Ecology UB RAS, 8 Marta str. 202, 620144, Ekaterinburg (Russian Federation); Karimullina, Elina M. [Institute of Plant and Animal Ecology UB RAS, 8 Marta str. 202, 620144, Ekaterinburg (Russian Federation); Department of Developmental and Cell Biology, University of California, 2011 Biological Sciences III, Irvine, CA 92697-2300 (United States); Roeder, Marion S. [Leibniz Institute of Plant Genetics and Crop Plant Research, Corrensstrasse 3, D-06466, Gatersleben (Germany)

    2014-07-01

    This investigation dedicates the problem of remote consequences of radiation impact on plant populations. This is a part of a complex research, which includes the classic triad of radioecology (Timofeev-Ressovsky 1963): 'accumulation and migration of radionuclides in different components of ecosystems - assessment of radiation dose - investigation of radiobiological effects'. We used the populations of smooth brome (Bromus inermis Leyss.) as a model system for the investigation of radiobiological and genetic effects. It is radiosensitive plant (Preobrazhenskaya 1971). These species may be used as objects for bio-indication at the radioactive contaminated areas, and as well as large-scale radioecological studies, because the adaptation processes are faster for radiosensitive species (Shevchenko et al., 1992; Pozolotina et al. 2005). We calculated external and internal whole-body dose rates by ERICA Tool (Karimullina et al., 2013). The total dose rate for brome was under 100 mGy h{sup -1} at the most polluted site but 43-110 times (Tier 3) exceeded the background along the pollution gradient. Therefore it can be concluded that herbaceous plant populations currently exist under low level chronic exposure at the EURT area. During seven years we have studied variability of viability, mutability and radioresistance of brome seed progeny. The combined effects of radiation exposure and weather conductions at the EURT area were absent. It may be connect with wide variability of inter-population test parameters. At the same time the weather conductions had an influence on the quality of seed progeny at the background area. We analyzed also correlation between original viability and radioresistance of seed progeny from the all plots. This dependence was positive. It was shown negative dependence between original viability of seed progeny and low weight molecular antioxidants content too. Ionizing radiation is a mutagenic factor and, accordingly, elevated mutation

  4. Shot noise in radiobiological systems.

    Science.gov (United States)

    Datesman, A

    2016-11-01

    As a model for human tissue, this report considers the rate of free radical generation in a dilute solution of water in which a beta-emitting radionuclide is uniformly dispersed. Each decay dissipates a discrete quantity of energy, creating a large number of free radicals in a short time within a small volume determined by the beta particle range. Representing the instantaneous dissipated power as a train of randomly-spaced pulses, the time-averaged dissipated power p¯ and rate of free radical generation g¯ are derived. The analogous result in the theory of electrical circuits is known as the shot noise theorem. The reference dose of X-rays Dref producing an identical rate of free radical generation and level of oxidative stress is shown a) to increase with the square root of the absorbed dose, D, and b) to be far larger than D. This finding may have important consequences for public health in cases where the level of shot noise exceeds some noise floor corresponding to equilibrium biological processes. An estimate of this noise floor is made using the example of potassium-40, a beta-emitting radioisotope universally present in living tissue.

  5. The Avenging Females: A Comparative Analysis of Kill Bill Vol.1-2, Death Proof and Sympathy for Lady Vengeance

    Directory of Open Access Journals (Sweden)

    Basak Göksel Demiray

    2012-04-01

    Full Text Available This paper provides a comparative analysis of Quentin Tarantino’s Kill Bill Vol.1-2 (2003, 2004, Death Proof (2007 and Park Chan Wook’s Sympathy for Lady Vengeance (Chinjeolhan Geumjassi, 2005. The primary objectives of this study are: (1 to reveal the gender-biases inherent to the fundamental discursive structures of the foregoing films; (2 to compare and contrast the films through an analysis of the ‘gaze(s’ and possible ‘pleasures’,  which are inherent in their narratives, in relation to Laura Mulvey’s and Carol Clover’s approaches; and (3 to distinguish Kill Bill Vol.1-2 from the foregoing two and the ‘avenging female’ clichés of the other horror/violence movies in the context of the replaced positionings of its protagonist and antagonist inherent in its distinct narrative style.

  6. 发现美丽真我养成记VOL.2预备开跑!

    Institute of Scientific and Technical Information of China (English)

    潘俣宁

    2009-01-01

    “Shiningstar养成记”第二阶段的主角终于确定,在吸取了VOL.1的成功经验与不足后,养成记VOL.2将以崭新姿态全力开跑。迷人的外表固然重要,美丽的内心更是我们不懈努力的目标。

  7. Análise qualitativa de compostos voláteis do headspace de carne cozida de ovinos e caprinos

    Directory of Open Access Journals (Sweden)

    Jossiê Zamperetti Donadel

    2013-11-01

    Full Text Available Este estudo teve como objetivo caracterizar qualitativamente os compostos voláteis (CV do headspace de diferentes músculos de carne cozida de ovinos e caprinos da região do Alto Camaquã, Rio Grande do Sul - Brasil. Os CV do headspace dos músculos cozidos, L. dorsi e V. lateralis de cinco ovinos machos (idade de 6 meses e cinco cabritos machos castrados (idade de 8-9 meses foram analisados pela técnica de microextração em fase sólida (HS-SPME e cromatógrafo a gás acoplado a espectrômetro de massas (GC/MS. Foram encontrados 73 compostos voláteis, dentre eles aldeídos, cetonas e compostos sulfurados, característicos de carne processada termicamente. A partir da fração volátil, foi possível encontrar marcadores que discriminassem as espécies animais estudadas, caracterizando os caprinos por apresentarem, entre outros compostos, terpenos (β-pineno, α-gurjuneno, α-muuroleno, ausentes em ovinos. Alguns compostos discriminaram V. lateralis e L. dorsi de ovinos, como álcool isopropílico, α-pineno, o-xileno, porém não foi possível obter uma diferenciação entre os músculos de caprinos.

  8. Effect of sintering temperature and time intervals on morphological and hardness behaviour of Al-20 vol% Sn matrix composites

    Science.gov (United States)

    Badarulzaman, N. A.; Karim, S. R.; Lajis, M. A.

    2015-05-01

    Aluminium (Al) alloys are widely used in various industries, such as automotive and aerospace. The production processes in these sectors create large amount of Al residues. In this paper, a new method of recycling Al chip is presented. Metal matrix composite (MMCs) of Al-20 vol% Sn was prepared by using solid state direct conversion method of recycled Al 6061 alloy. Constant pressure (10 ton) was used to implement the cold forging process. The differences of sintering temperature (200 °C, 250 °C, 300 °C and 350 °C) and time intervals (1h, 2h, 3h, 4h and 5h) were studied to obtain the optimum hardness, strength and surface integrity of Al-20 vol% Sn. The results showed that, hardness and strength of Al-20 vol% Sn was decreased by additional temperature and increase with time interval of sintering. Sintering temperature at 350 °C produces better morphology structure of Al-Sn composites.

  9. Juha Manninen and Friedrich Stadtler (eds., The Vienna Circle and the Nordic Countries. Networks and Transformations of Logical Empiricism (Vienna: Vienna Circle Institute Yearbook vol.14, Springer, 2010

    Directory of Open Access Journals (Sweden)

    Carlo Penco

    2013-03-01

    Full Text Available A discussion of The Vienna Circle and the Nordic Countries. Networks and Transformations of Logical Empiricism, edited by Juha Manninen and Friedrich Stadtler, Vienna Circle Institute Yearbook vol.14, Springer, 2010.

  10. Michele Renee Salzman, Marvina A. Sweeney & William Adler (eds., The Cambridge History of Religions in the Ancient World (2 vols. (New York: Cambridge University Press, 2013

    Directory of Open Access Journals (Sweden)

    Giorgio Baruchello

    2014-03-01

    Full Text Available Review of: Michele Renee Salzman, Marvina A. Sweeney & William Adler (eds., The Cambridge History of Religions in the Ancient World (2 vols. (New York: Cambridge University Press, 2013

  11. Recommendations from gynaecological (GYN) GEC ESTRO working group (II): concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy-3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology.

    Science.gov (United States)

    Pötter, Richard; Haie-Meder, Christine; Van Limbergen, Erik; Barillot, Isabelle; De Brabandere, Marisol; Dimopoulos, Johannes; Dumas, Isabelle; Erickson, Beth; Lang, Stefan; Nulens, An; Petrow, Peter; Rownd, Jason; Kirisits, Christian

    2006-01-01

    The second part of the GYN GEC ESTRO working group recommendations is focused on 3D dose-volume parameters for brachytherapy of cervical carcinoma. Methods and parameters have been developed and validated from dosimetric, imaging and clinical experience from different institutions (University of Vienna, IGR Paris, University of Leuven). Cumulative dose volume histograms (DVH) are recommended for evaluation of the complex dose heterogeneity. DVH parameters for GTV, HR CTV and IR CTV are the minimum dose delivered to 90 and 100% of the respective volume: D90, D100. The volume, which is enclosed by 150 or 200% of the prescribed dose (V150, V200), is recommended for overall assessment of high dose volumes. V100 is recommended for quality assessment only within a given treatment schedule. For Organs at Risk (OAR) the minimum dose in the most irradiated tissue volume is recommended for reporting: 0.1, 1, and 2 cm3; optional 5 and 10 cm3. Underlying assumptions are: full dose of external beam therapy in the volume of interest, identical location during fractionated brachytherapy, contiguous volumes and contouring of organ walls for >2 cm3. Dose values are reported as absorbed dose and also taking into account different dose rates. The linear-quadratic radiobiological model-equivalent dose (EQD2)-is applied for brachytherapy and is also used for calculating dose from external beam therapy. This formalism allows systematic assessment within one patient, one centre and comparison between different centres with analysis of dose volume relations for GTV, CTV, and OAR. Recommendations for the transition period from traditional to 3D image-based cervix cancer brachytherapy are formulated. Supplementary data (available in the electronic version of this paper) deals with aspects of 3D imaging, radiation physics, radiation biology, dose at reference points and dimensions and volumes for the GTV and CTV (adding to [Haie-Meder C, Pötter R, Van Limbergen E et al. Recommendations from

  12. A review of the clinical experience in pulsed dose rate brachytherapy.

    Science.gov (United States)

    Balgobind, Brian V; Koedooder, Kees; Ordoñez Zúñiga, Diego; Dávila Fajardo, Raquel; Rasch, Coen R N; Pieters, Bradley R

    2015-01-01

    Pulsed dose rate (PDR) brachytherapy is a treatment modality that combines physical advantages of high dose rate (HDR) brachytherapy with the radiobiological advantages of low dose rate brachytherapy. The aim of this review was to describe the effective clinical use of PDR brachytherapy worldwide in different tumour locations. We found 66 articles reporting on clinical PDR brachytherapy including the treatment procedure and outcome. Moreover, PDR brachytherapy has been applied in almost all tumour sites for which brachytherapy is indicated and with good local control and low toxicity. The main advantage of PDR is, because of the small pulse sizes used, the ability to spare normal tissue. In certain cases, HDR resembles PDR brachytherapy by the use of multifractionated low-fraction dose.

  13. Retraction: On the origin of power-law distributions in systems with constrained phase space [Condens. Matter Phys., 2013, vol. 16, 43802

    Directory of Open Access Journals (Sweden)

    Editorial Board

    2014-03-01

    Full Text Available The article Condens. Matter Phys., 2013, vol. 16, 43802 ( DOI:10.5488/CMP.16.43802 has been retracted by the decision of the Editorial Board. There is a significant overlap with an article: Phys. Rev. E, 2006, vol. 74, 036120 ( DOI:10.1103/PhysRevE.74.036120. Appologies are offered to readers of the journal that this was not detected during the submission process.

  14. Guidelines for the Use of Antiretroviral Agents in Pediatric HIV Infection. Vol. 47/No. RR-4.

    Science.gov (United States)

    1998-04-17

    dren. Growth failure and neurodevelopmental deterioration may be specific manifestations of HIV infection in children. Nutritional -support therapy is...infected chil- dren with immunologic or clinical symptoms of HIV infection. Studies have dem- onstrated substantial improvements in neurodevelopment ...count (e.g., a >30% decline in ɞ months). Clinical Considerations • Progressive neurodevelopmental deterioration. • Growth failure defined as

  15. MO-D-BRD-01: Clinical Implementation of An Electronic Brachytherapy Program for the Skin

    Energy Technology Data Exchange (ETDEWEB)

    Ouhib, Z. [Lynn Regional Cancer Center (United States)

    2015-06-15

    Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic

  16. Efecto del aceite de sacha inchi (plukenetia volúbilis l) sobre el perfil lipídico en pacientes con hiperlipoproteinemia Effect of sacha inchi oil (plukenetia volúbilis l) on the lipid profile of patients with hyperlipoproteinemia

    OpenAIRE

    Fausto Garmendia; Rosa Pando; Gerardo Ronceros

    2011-01-01

    El presente es un trabajo experimental piloto, abierto, para conocer el efecto, dosis efectiva y efectos secundarios del aceite de sacha inchi (Plukenetia volúbilis L) en el perfil lipídico de pacientes con hipercolesterolemia; para ello, se incluyó a 24 pacientes de 35 a 75 años, en quienes se determinó los valores sanguíneos de colesterol total (CT), HDL, triglicéridos (Tg), glucosa, ácidos grasos no esterificados (AGNE) e insulina Se aleatorizó a los participantes para recibir 5 mL o 10 mL...

  17. Image quality and volume computed tomography air kerma index (C{sub vol}) evaluation in Recife; Avaliacao da qualidade de imagem e do indice volumetrico de Kerma ar em tomografia computadorizada (C{sub vol}) em Recife

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Marcos Ely Almeida

    2008-07-01

    The Computed Tomography (CT) is an important diagnostic imaging method, widely used. However, in spite of all the advantages and technologic advances within the CT scanners, the tomographic procedures result in high absorbed doses to patients. The main objective of this work was to perform a dosimetric study of CT scanners located at Recife and to evaluate the image quality on CT examinations in these equipment. The volume CT air kerma index (C{sub VOL}) and air kerma length product (P{sub KL,CT}) were estimated. These values were calculated using normalized weighted air kerma indexes in CT standard dosimetry phantoms ({sub n}C{sub W}), supplied by ImPACT group for several CT scanners, and the scan parameters of routine head, routine chest and hi-resolution chest CT exams performed at 20 institutions. The irradiation parameters of 15 adult patients for each CT procedure were registered at six participating centres, at which the phantom from the American College of Radiology (ACR) CT accreditation protocol was used for the image quality measurements. For routine head exams, the C{sub VOL} values varied between 12 and 58 mGy (at the posterior fossa) and 15 to 58 mGy (at the cerebrum) and the P{sub KL,CT}, from 150 to 750 mGy{center_dot}cm. The C{sub VOL} values for routine chest procedures varied from 3 to 26 mGy and the P{sub KL,CT}, between 120 and 460 mGy{center_dot}cm. In relation to Hi-resolution chest exams, C{sub VOL} values were from 1.0 to 2.7 mGy and the P{sub KL,CT} values varied between 24 and 67 mGy{center_dot}cm. The image quality evaluations results showed that almost all scanners presented at least one inadequacy. One of the equipment presented faults at 70% of the tests. With regard to the image noise, only two scanners presented acceptable results. From these results, it is possible to conclude that the volume CT air kerma index values are lower than the European reference levels. However, the image quality of these CT scanners does not attend the

  18. Clinical aspects and potential clinical applications of laser accelerated proton beams

    Science.gov (United States)

    Spatola, C.; Privitera, G.

    2013-07-01

    Proton beam radiation therapy (PBRT), as well as the other forms of hadrontherapy, is in use in the treatment of neoplastic diseases, to realize a high selective irradiation with maximum sparing of surrounding organs. The main characteristic of such a particles is to have an increased radiobiological effectiveness compared to conventional photons (about 10% more) and the advantage to deposit the energy in a defined space through the tissues (Bragg peak phenomenon). The goal of ELIMED Project is the realization of a laser accelerated proton beam line to prove its potential use for clinical application in the field of hadrontherapy. To date, there are several potential clinical applications of PBRT, some of which have become the treatment of choice for a specific tumour, for others it is under investigation as a therapeutic alternative to conventional X-ray radiotherapy, to increase the dose to the tumour and reduce the side effects. For almost half of cancers, an increased local tumour control is the mainstay for increased cancer curability.

  19. Handbook on criticality. Vol. 1. Criticality and nuclear safety; Handbuch zur Kritikalitaet. Bd. 1. Kritikalitaet und nukleare Sicherheit

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-04-15

    This handbook was prepared primarily with the aim to provide information to experts in industry, authorities or research facilities engaged in criticality-safety-related problems that will allow an adequate and rapid assessment of criticality safety issues already in the planning and preparation of nuclear facilities. However, it is not the intention of the authors of the handbook to offer ready solutions to complex problems of nuclear safety. Such questions have to remain subject to an in-depth analysis and assessment to be carried out by dedicated criticality safety experts. Compared with the previous edition dated December 1998, this handbook has been further revised and supplemented. The proven basic structure of the handbook remains unchanged. The handbook follows in some ways similar criticality handbooks or instructions published in the USA, UK, France, Japan and the former Soviet Union. The expedient use of the information given in this handbook requires a fundamental understanding of criticality and the terminology of nuclear safety. In Vol. 1, ''Criticality and Nuclear Safety'', therefore, first the most important terms and fundamentals are introduced and explained. Subsequently, experimental techniques and calculation methods for evaluating criticality problems are presented. The following chapters of Vol. 1 deal i. a. with the effect of neutron reflectors and absorbers, neutron interaction, measuring methods for criticality, and organisational safety measures and provide an overview of criticality-relevant operational experience and of criticality accidents and their potential hazardous impact. Vol. 2 parts 1 and 2 finally compile criticality parameters in graphical and tabular form. The individual graph sheets are provided with an initially explained set of identifiers, to allow the quick finding of the information of current interest. Part 1 includes criticality parameters for systems with {sup 235}U as fissile material, while part

  20. Determinación de los compuestos volátiles en pentacalia vaccinioides, su estudio antioxidante y antimicrobiano

    OpenAIRE

    Castellanos Gómez, María Angélica

    2014-01-01

    El trabajo realizado con la Pentacalia vaccinioides fue complemento al Estudio Químico y Antimicrobiano de Plantas Autóctonas de Páramos Colombianos , realizado por investigadores de la Universidad Javeriana. Este trabajo contribuyó al conocimiento de los compuestos volátiles de la Pentacalia así como también al fortalecimiento de la línea de aceites esenciales (AEs) de la maestría en Ciencias Biológicas. En el desarrollo se emplearon diferentes técnicas de extracción para aislar los metabol...

  1. Next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beams

    Science.gov (United States)

    Niklas, Martin; Zimmermann, Ferdinand; Chaudhri, Naved; Krunic, Damir; Tessonnier, Thomas; Ferrari, Alfredo; Parodi, Katia; Jäkel, Oliver; Debus, Jürgen; Haberer, Thomas; Abdollahi, Amir

    2016-01-01

    The growing number of particle therapy facilities worldwide landmarks a novel era of precision oncology. Implementation of robust biophysical readouts is urgently needed to assess the efficacy of different radiation qualities. This is the first report on biophysical evaluation of Monte Carlo simulated predictive models of prescribed dose for four particle qualities i.e., proton, helium-, carbon- or oxygen ions using raster-scanning technology and clinical therapy settings at HIT. A high level of agreement was found between the in silico simulations, the physical dosimetry and the clonogenic tumor cell survival. The cell fluorescence ion track hybrid detector (Cell-Fit-HD) technology was employed to detect particle traverse per cell nucleus. Across a panel of radiobiological surrogates studied such as late ROS accumulation and apoptosis (caspase 3/7 activation), the relative biological effectiveness (RBE) chiefly correlated with the radiation species-specific spatio-temporal pattern of DNA double strand break (DSB) formation and repair kinetic. The size and the number of residual nuclear γ-H2AX foci increased as a function of linear energy transfer (LET) and RBE, reminiscent of enhanced DNA-damage complexity and accumulation of non-repairable DSB. These data confirm the high relevance of complex DSB formation as a central determinant of cell fate and reliable biological surrogates for cell survival/RBE. The multi-scale simulation, physical and radiobiological characterization of novel clinical quality beams presented here constitutes a first step towards development of high precision biologically individualized radiotherapy. PMID:27494855

  2. Identificação de compostos voláteis de maçãs (Malus domestica cultivar Fuji, por cromatografia gasosa-espectrometria de massas

    Directory of Open Access Journals (Sweden)

    JANZANNTTI Natália S.

    2000-01-01

    Full Text Available Os compostos voláteis da maçã cultivar Fuji foram estudados durante 2 anos consecutivos (1994 e 1995. O isolamento dos compostos voláteis da maçã Fuji foi feito utilizando-se uma técnica de enriquecimento dos voláteis do "headspace" em Porapak Q e eluição com hexano. Foram detectados 84 componentes voláteis na maçã Fuji, por cromatografia gasosa de alta resolução, dos quais trinta foram identificados por cromatografia gasosa-espectrometria de massas, aliada aos índices de Kovats. Os compostos majoritários foram os ésteres acetato de butila, acetato de 2-metil butila, acetato de hexila e o terpeno µ-farneseno. A classe química predominante, entre compostos voláteis na maçã Fuji, foi a dos ésteres.

  3. [Treatment with neutrons: hadrontherapy part II: physical basis and clinical experience].

    Science.gov (United States)

    Noël, G; Feuvret, L; Ferrand, R; Mazeron, J-J

    2003-10-01

    Neutrons have radiobiological characteristics, which differ from those of conventional radiotherapy beams (photons) and which offer a theoretical advantage over photons to fight radioresistance by the differential relative biological effect of them between normal and tumour tissues. Neutron therapy beneficed of great interest between 1975 and 1985. Many of phase III trials were conducted and indications have been definitively deducted of them. After briefly describing the properties of neutron beams, this review discusses the indication of neutron therapy on the basis of the clinical results. Salivary, prostate tumours and sarcomas are the main indications of neutron therapy. In concern to the prostate cancers, other alternative treatments reduce the neutron therapy field. For sarcomas, the lack of randomised trials limits the impact of the interest of neutrons. For other tumours, the ratio benefice/risk of neutron therapy is inferior to these obtained with photons and they could not be considered like classical indications.

  4. Functional imaging in oncology. Biophysical basis and technical approaches. Vol. 1

    Energy Technology Data Exchange (ETDEWEB)

    Luna, Antonio [Health Time Group, Jaen (Spain); University Hospitals, Case Western Reserve Univ., Cleveland, OH (United States). Dept. of Radiology; Vilanova, Joan C. [Clinica Girona - Hospital Sta. Caterina, Girona (Spain); Hygino da Cruz, L. Celso Jr. [CDPI and IRM, Rio de Janeiro, RJ (Brazil). Dept. of Radiology; Rossi, Santiago E. (ed.) [Centro de Diagnostico, Buenos Aires (Argentina)

    2014-07-01

    Easy-to-read manual on new functional imaging techniques in oncology. Explains current clinical applications and outlines future avenues. Includes numerous high-quality illustrations to highlight the major teaching points. In the new era of functional and molecular imaging, both currently available imaging biomarkers and biomarkers under development are expected to lead to major changes in the management of oncological patients. This well-illustrated two-volume book is a practical manual on the various imaging techniques capable of delivering functional information on cancer, including preclinical and clinical imaging techniques, based on US, CT, MRI, PET and hybrid modalities. This first volume explains the biophysical basis for these functional imaging techniques and describes the techniques themselves. Detailed information is provided on the imaging of cancer hallmarks, including angiogenesis, tumor metabolism, and hypoxia. The techniques and their roles are then discussed individually, covering the full range of modalities in clinical use as well as new molecular and functional techniques. The value of a multiparametric approach is also carefully considered.

  5. 5. German congress on radiation oncology, radiobiology and medical physics. Book of abstracts, DEGRO congress; 5. Deutscher Kongress fuer Radioonkologie, Strahlenbiologie und Medizinische Physik. Abstractband zum DEGRO-Kongress

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1999-11-01

    The special issue of the journal covers the scientific conference program, encompassing 32 symposia and the invited papers, as well as about 300 scientific papers and posters presented at the congress. Most of the papers of the symposium sessions take a cross-disciplinary approach in discussing the large tumor entities and recent advances on the technical and biological level. Subject clusters are medical and physical quality assurance and radiobiology, CNS, ENT, brachytherapy, and benign tumors. One symposium gathered specialists discussing economic and legal aspects. Further topical fields are foreeseable trends and innovative developments for the treatment of cancer of the prostate, breast, and bronchial tract, or enhanced application of radiochemotherapy, the knowledge and contributions from the field of molecular biology, and new technology, including the new media. (orig./CB) [German] Das wissenschaftliche Programm setzt sich zusammen aus 32 Symposien und jeweils ca. 300 freien Vortraegen und Posterpraestentationen. In den Symposien werden mehrheitlich interdisziplinaer sowohl die grossen Tumorentitaeten als auch technische und biologische Neuerungen vorgestellt. Thematische Schwerpunkte sind die medizinische und physikalische Qualitaetssicherung sowie die Strahlenbiologie, gefolgt von den Themenbereichen ZNS, HNO, Brachytherapie und gutartigen Erkrankungen. Ein Symposium widmet sich Wirtschaftlichkeits- und Rechtsfragen. Weitere zukunftsweisende Themenschwerpunkte sind Innovationen beim Prostata-, Mamma- und Bronchialkarzinom sowie der zunehmende Einsatz der Radiochemotherapie, die Nutzung der Kenntnisse aus der Molekularbiologie und technische Neuerungen inklusive der neuen Medien. (orig.)

  6. The Nasa space radiation school, an excellent training in radiobiology and space radiation protection; La NASA space radiation summer school, une formation d'excellence en radiobiologie et radioprotection spatiale

    Energy Technology Data Exchange (ETDEWEB)

    Vogin, G. [Centre Alexis-Vautrin, 54 - Nancy (France)

    2009-10-15

    The astronauts have to spend more time in space and the colonization of the moon and Mars are in the cross hairs of international agencies. The cosmic radiation from which we are protected on ground by atmosphere and by the terrestrial magnetosphere (.4 mSv/year according to Who) become really threatening since 20 km altitude, delivering an average radiation dose of a therapeutic kind to astronauts with peaks related to solar events. It is composed in majority of hadrons: protons (85%) and heavy ions (13%), but also photons (2%) of high energy (GeV/n)). the incurred risks are multiple: early ones(cataract, central nervous system damages, whole body irradiation) but especially delayed ones (carcinogenesis). The astronauts radiation protection turns poor and the rate of death risk by cancer returning from a mission on Mars has been estimated at 5%. The Nasa created in 2004 a summer school aiming to awareness young researchers to the space radiobiology specificities. Areas concerned as follow: radioinduced DNA damage and repair, cell cycle, apoptosis, bystander effect, genome instability, neuro degeneration, delayed effects and carcinogenesis in relation with radiation exposure. (N.C.)

  7. Actividad antioxidante de compuestos aislados del residuo no-volátil del aceite esencial de naranja.

    Directory of Open Access Journals (Sweden)

    Vargas-Arispuro, L.

    1998-04-01

    Full Text Available There has been a growing interest in the food industry and in preventive medicine to search for «natural antioxidants». Therefore the objetive of this study was to evaluate the antioxidant activity of the non-volatile residue of essential orange oil in the oxidation of unrefined and freshly extracted olive oil. Essential orange oil was distilled to obtain a non-volatile residue and fracctionated on a Silica Gel 60 column. The antioxidant activity was determined by measuring peroxide value obtained after heating olive oil at 70 °C for 48 h. Six compounds were isolated and purified, four of these had antioxidant activity, α-tocopherol and three methoxylated flavones were identified using spectroscopic methods. This study confirmed that non-volatile fractions of essential orange oil contain natural antioxidants diferent from α-tocopherol.

    Existe un creciente interés en la industria alimentaria y en la medicina preventiva por la búsqueda de «antioxidantes naturales», por lo que nos planteamos evaluar la actividad antioxidante del residuo no volátil del aceite esencial de naranja contra la oxidación del aceite de oliva sin retinar y de reciente extracción. Mediante destilación del aceite esencial de naranja se obtuvo el residuo no-volátil, el cual se fraccionó en columna de silica gel 60. La actividad antioxidante fue medida por el valor de peróxidos producidos por el aceite de oliva al provocar la oxidación por calentamiento a 70 °C durante 48 h. Se aislaron seis compuestos mediante HPLC preparativo de los cuales cuatro tuvieron actividad antioxidante. Usando métodos espectroscópicos se identificaron α-tocoferol y tres flavonas metoxiladas. Con este estudio se confirmó que la fracción no volátil del aceite esencial de naranja contiene antioxidantes naturales diferentes al α-tocoferol.

  8. Simplified voxel based and automatic VOl analysis of C-11 PIB uptake using a ligand and subject specific PET templates

    Energy Technology Data Exchange (ETDEWEB)

    Chae, S. Y.; Lee, J. H.; Oh, S. J. [Asan Medical Center, Seoul (Korea, Republic of)] (and others)

    2007-07-01

    We developed simplified analysing method of C-11 PIB PET using a ligand and subject specific PET templates and evaluated the usefulness of this method by comparing standard MR-based methods in Alzheimer disease (AD). We studied 7 patients with AD (71.5{+-}11.5, M/F=3/4) and 5 normal controls (68.4{+-}8.9, M/F=1/4) with C-11 PIB PET and T1 MRI. 90-min dynamic PET scan was performed after injection of C-11 PIB (370 MBq). Region to cerebellar ratio image (ratio image) was obtained from 60-90 min image and distribution volume ratio image (DVR image) was obtained from 90-min dynamic image using a Logan graphical analysis. Ligand and subject specific PET templates were created by spatial normalization of MR coregistered ratio images of AD and normal group to T1 MR MNI template using SPM2. We compared the outcome of voxel based and automatic VOl analysis employing 3 parametric images: MR template based spatially normalized MR coregistered DVR image (MR-DVR image), MR template based normalized MR coregistered ratio image (MR-ratio image), AD and normal group specific PET template based normalized ratio image (PET-ratio image) in all subjects. Voxel based analyses using 3 parametric images revealed significantly increased PIB retention in several brain regions such as both orbitofrontal and temporoparietal cortices and posterior cingulated gyri of AD compared to normal (FDR<0.05), however, the z-values of these regions were more higher in PET- and MR-ratio images than in MR-DVR image. Automatic VOl analyses using 3 parametric images also revealed significantly increased PIB retention values in same regions of AD (p<0.05). PIB retention values in PET-ratio images were significantly correlated with those in MR-ratio images (R=0.96, slope=0.99, p<0.001) and also MR-DVR images (R=0.95, slope = 1.8, p<0.001). Voxel based and automatic VOl analysis can be simply and accurately performed in a single static C-11 PIB PET image using a ligand and subject specific PET templates

  9. Volúmenes molales parciales de transferencia de algunas sulfonamidas desde el agua hasta la mezcla agua-etanol (X = 0.5)

    OpenAIRE

    2002-01-01

    A partir de valores de densidad de soluciones de diferentes concentraciones, determinados a 25,00 °C, se calcularon los volúmenes molales parciales de transferencia a dilución infinita de algunas sulfonamidas estructuralmente relacionadas, como especies moleculares y como sales sódicas, desde el agua hasta la mezcla agua-etanol de composición 0.5 en fracción molar; adicionalmente se calcularon los volúmenes de los grupos sustituyentes. Los resultados se discuten en términos de interacciones e...

  10. Efeito do processamento na composição de voláteis de suco clarificado de maçã Fuji

    Directory of Open Access Journals (Sweden)

    Janzantti Natália S.

    2003-01-01

    Full Text Available Os compostos voláteis são responsáveis pelo sabor característico dos alimentos, são termolábeis e também facilmente perdidos ou modificados durante o processamento. Este estudo teve como objetivo verificar o efeito do processamento na composição de voláteis do suco clarificado de maçãs Fuji. O isolamento dos voláteis foi feito por enriquecimento do "headspace" em polímero poroso e eluição com hexano. Oitenta e quatro compostos voláteis foram detectados na maçã Fuji, por cromatografia gasosa de alta resolução, dos quais 30 foram identificados por espectrometria de massas, aliada aos índices de Kovats. A classe química predominante na maçã Fuji, dentre os compostos identificados, foi a dos ésteres, compreendendo ao todo 28 voláteis. Os compostos majoritários na fruta foram a-farneseno, acetato de 2-metil butila, acetato de butila e acetato de hexila. Após a prensagem, o aldeído hexanal aumentou drasticamente e se tornou majoritário. A clarificação foi a etapa que menos causou modificações na composição de voláteis, mantendo o aldeído como majoritário. A pasteurização foi a etapa crítica do processamento, como esperado. Nesta etapa, além de ocorrer a diminuição da área de todos os componentes voláteis, ocorreu a perda total do éster octanoato de isoamila e de 15 compostos não identificados. No entanto, os compostos voláteis majoritários após a prensagem e em todas as etapas do processamento foram os mesmos: acetato de butila, acetato de 2-metil butila, acetato de hexila e um composto não identificado.

  11. Diffusion Brazing of Al6061/15 Vol. Pct Al2O3p Using a Cu-Sn Interlayer

    Science.gov (United States)

    Cooke, Kavian O.; Khan, Tahir I.; Oliver, Gossett D.

    2013-06-01

    Diffusion brazing of Al-6061 alloy containing 15 vol. pct Al2O3 particles was attempted using Cu-Sn interlayer. Joint formation was attributed to the solid-state interdiffusion of Cu and Sn followed by eutectic formation and subsequent isothermal solidification. Examination of the joint region using scanning electron microprobe analyzer (EPMA), wavelength dispersive spectroscopy (WDS) and X-ray diffraction (XRD) showed the formation of intermetallic phases such as Al7Cu3Mg3, Mg2Cu6Al5, Cu3Sn, and Mg2Sn. The results indicated an increase in joint strength with increasing bonding time giving the highest joint shear strength of 94 MPa at a bonding duration of 3 hours.

  12. ALERT. Adverse late effects of cancer treatment. Vol. 1. General concepts and specific precepts

    Energy Technology Data Exchange (ETDEWEB)

    Rubin, Philip; Constine, Louis S. [Univ. Rochester Medical Center, NY (United States). Dept. of Radiation Oncology; Marks, Lawrence B. (ed.) [Univ. North Carolina and Lineberger, Comprehensive Cancer Center, Chapel Hill, NC (United States). Dept. of Radiation Oncology

    2014-09-01

    Considers in detail the general concepts and principles relevant to the adverse late effects of cancer treatment. Explains the molecular, cytologic and histopathologic events that lead to altered physiologic and metabolic functions and their clinical manifestations. Includes chapters on legal issues, economic aspects, nursing, psychological issues and quality of life. The literature on the late effects of cancer treatment is widely scattered in different journals since all major organ systems are affected and management is based on a variety of medical and surgical treatments. The aim of ALERT - Adverse Late Effects of Cancer Treatment is to offer a coherent multidisciplinary approach to the care of cancer survivors. The central paradigm is that cytotoxic multimodal therapy results in a perpetual cascade of events that affects each major organ system differently and is expressed continually over time. Essentially, radiation and chemotherapy are intense biologic modifiers that allow for cancer cure and cancer survivorship but accelerate senescence of normal tissues and increase the incidence of age-related diseases and second malignant tumors. Volume 1 of this two-volume work focuses on the general concepts and principles relevant to late effects and on the dynamic interplay of molecular, cytologic and histopathologic events that lead to altered physiologic and metabolic functions and their clinical manifestations. Chapters are also included on legal issues, economic aspects, nursing, psychological issues and quality of life.

  13. Modeling Clinical Radiation Responses in the IMRT Era

    Science.gov (United States)

    Schwartz, J. L.; Murray, D.; Stewart, R. D.; Phillips, M. H.

    2014-03-01

    The purpose of this review is to highlight the critical issues of radiobiological models, particularly as they apply to clinical radiation therapy. Developing models of radiation responses has a long history that continues to the present time. Many different models have been proposed, but in the field of radiation oncology, the linear-quadratic (LQ) model has had the most impact on the design of treatment protocols. Questions have been raised as to the value of the LQ model given that the biological assumption underlying it has been challenged by molecular analyses of cell and tissue responses to radiation. There are also questions as to use of the LQ model for hypofractionation, especially for high dose treatments using a single fraction. While the LQ model might over-estimate the effects of large radiation dose fractions, there is insufficient information to fully justify the adoption of alternative models. However, there is increasing evidence in the literature that non-targeted and other indirect effects of radiation sometimes produce substantial deviations from LQ-like dose-response curves. As preclinical and clinical hypofractionation studies accumulate, new or refined dose-response models that incorporate high-dose/fraction non-targeted and indirect effects may be required, but for now the LQ model remains a simple, useful tool to guide the design of treatment protocols.

  14. TAI CHI CHUAN: STATE OF THE ART IN INTERNATIONAL RESEARCH: VOL 52 (MEDICINE & SPORT SCIENCE

    Directory of Open Access Journals (Sweden)

    Youlian Hong

    2008-09-01

    Full Text Available DESCRIPTION This collection on the latest and practical research data about the characteristics and beneficial effects of Tai Chi Chuan on various physiological and pathological matters is published as the 52nd volume of Medicine and Sport Science Journal. PURPOSE To address the effects of Tai Chi Chuan in the fields of biomechanics and physiology, sensory motor control and fall prevention, psychology and social aspects, as well as various clinical applications. FEATURES The book is organised into four sections, each containing four to seven chapters: the first section focuses on biomechanical and physiological aspects of Tai Chi in seven chapters, the second section addresses the benefits of the sport in terms of sensory motor control and fall prevention in five chapters, the third section highlights the psychological and social aspects in four chapters, and in the last section the application of Tai Chi in clinical intervention such as in Parkinson's disease, Alzheimer's diseases, coronary heart disease, chronic heart failure, breast cancer, rheumatoid arthritis and diabetes is demonstrated in six chapters. AUDIENCE This is a thorough reference book for students, researchers, teachers and healthcare professionals in exercise science and medicine. In fact, anyone already practicing Tai Chi Chuan or considering it up would benefit from this book. ASSESSMENT This 52nd volume of Medicine and Sport Science Journal on Tai Chi Chuan is a valuable and essential source of information brought together by recognized researchers around the Globe. The book is for everybody who is interested in understanding the effects and application of this fascinating form of exercise which has been developed as a form of martial arts and used for health exercise for centuries in China.

  15. The Model Intercomparison Project on the Climatic Response to Volcanic Forcing (VolMIP): Experimental Design and Forcing Input Data for CMIP6

    Science.gov (United States)

    Zanchettin, Davide; Khodri, Myriam; Timmreck, Claudia; Toohey, Matthew; Schmidt, Anja; Gerber, Edwin P.; Hegerl, Gabriele; Robock, Alan; Pausata, Francesco; Ball, William T.; Bauer, Susanne E.; LeGrande, Allegra N.; Tsigaridis, Kostas

    2016-01-01

    The enhancement of the stratospheric aerosol layer by volcanic eruptions induces a complex set of responses causing global and regional climate effects on a broad range of timescales. Uncertainties exist regarding the climatic response to strong volcanic forcing identified in coupled climate simulations that contributed to the fifth phase of the Coupled Model Intercomparison Project (CMIP5). In order to better understand the sources of these model diversities, the Model Intercomparison Project on the climatic response to Volcanic forcing (VolMIP) has defined a coordinated set of idealized volcanic perturbation experiments to be carried out in alignment with the CMIP6 protocol. VolMIP provides a common stratospheric aerosol data set for each experiment to minimize differences in the applied volcanic forcing. It defines a set of initial conditions to assess how internal climate variability contributes to determining the response. VolMIP will assess to what extent volcanically forced responses of the coupled ocean-atmosphere system are robustly simulated by state-of-the-art coupled climate models and identify the causes that limit robust simulated behavior, especially differences in the treatment of physical processes. This paper illustrates the design of the idealized volcanic perturbation experiments in the VolMIP protocol and describes the common aerosol forcing input data sets to be used.

  16. [Book review] Developments in biological standardization (Vol. 49): Fish Biologics: Seriodiagnostics and Vaccines, edited by W. Hennessen and D. P. Andersen

    Science.gov (United States)

    Anderson, D.P.

    1981-01-01

    Review of: Developments in Biologicals, Vol. 49. Fish Biologics: Serodiagnostics and Vaccines. International Symposium, Leetown, W.Va., April 1981. Editor(s): Hennessen, W. (Bern); Andersen, D.P. (Leetown, W.Va.); Society/Societies: International Association of Biological Standardization, XII + 496 p., 90 fig., 110 tab., soft cover, 1981. ISBN: 978-3-8055-3471-0.

  17. Rotary-Balance Testing for Aircraft Dynamics (Les Essais sur Balance Rotative pour l’Etude de la Dynamique du Vol de l’Avion)

    Science.gov (United States)

    1990-01-01

    Applied Yawing Moments by Use of Rotary Balance Data. NACA TN 3321, 1954. 16. Bazzocchi, B.: Un Metodo per la Deterininazione alla Galleria del Vento...and’Barnhart, B. Spin Prediction Techniques. J. of Aircraft, Vol. 20, No. 2, Feb. 1983, pp. 97-101. 2. Valtorta, E.: Analisi delle prove in galleria con

  18. The Model Intercomparison Project on the climatic response to Volcanic forcing (VolMIP): experimental design and forcing input data for CMIP6

    Science.gov (United States)

    Zanchettin, Davide; Khodri, Myriam; Timmreck, Claudia; Toohey, Matthew; Schmidt, Anja; Gerber, Edwin P.; Hegerl, Gabriele; Robock, Alan; Pausata, Francesco S. R.; Ball, William T.; Bauer, Susanne E.; Bekki, Slimane; Dhomse, Sandip S.; LeGrande, Allegra N.; Mann, Graham W.; Marshall, Lauren; Mills, Michael; Marchand, Marion; Niemeier, Ulrike; Poulain, Virginie; Rozanov, Eugene; Rubino, Angelo; Stenke, Andrea; Tsigaridis, Kostas; Tummon, Fiona

    2016-08-01

    The enhancement of the stratospheric aerosol layer by volcanic eruptions induces a complex set of responses causing global and regional climate effects on a broad range of timescales. Uncertainties exist regarding the climatic response to strong volcanic forcing identified in coupled climate simulations that contributed to the fifth phase of the Coupled Model Intercomparison Project (CMIP5). In order to better understand the sources of these model diversities, the Model Intercomparison Project on the climatic response to Volcanic forcing (VolMIP) has defined a coordinated set of idealized volcanic perturbation experiments to be carried out in alignment with the CMIP6 protocol. VolMIP provides a common stratospheric aerosol data set for each experiment to minimize differences in the applied volcanic forcing. It defines a set of initial conditions to assess how internal climate variability contributes to determining the response. VolMIP will assess to what extent volcanically forced responses of the coupled ocean-atmosphere system are robustly simulated by state-of-the-art coupled climate models and identify the causes that limit robust simulated behavior, especially differences in the treatment of physical processes. This paper illustrates the design of the idealized volcanic perturbation experiments in the VolMIP protocol and describes the common aerosol forcing input data sets to be used.

  19. Uudised : Volüüm tuleb uue väljaandega! Lauluvõistlusega 1500 eurot! Raadio 2 valib Aastahitti!

    Index Scriptorium Estoniae

    2005-01-01

    Kodumaisest hip-hopmuusika kogumikust Vol. 3. Lauluvõistlusest, milles võivad osaleda autorid Euroopa Liidust ja Lõuna-Vahemere riikidest (info: www.europa.eu.int/youth). R2 koduleheküljel www.r2.ee/aastahitt saab valida aasta parimat laulu

  20. Corrosión del cobre por ácidos orgánicos volátiles

    Directory of Open Access Journals (Sweden)

    Cano, E.

    2004-12-01

    Full Text Available The corrosion of copper in the presence of volatile organic acids is frequent. Thus, for example, it is known that failures by corrosion of the copper tubes take place in the air conditioning equipment, caused by volatile organic acids emitted by oils used in their manufacturing. Another frequent case is the corrosion of copper objects caused by the acids emitted by the materials used in packing, wood and resins, amongst others. This communication presents the corrosion results of copper exposed to 100% relative humidity and different concentrations (10-300 ppm of formic [HCOOH], acetic [CH3COOH], propionic [CH3CH2COOH] and butyric [CH3(CH22COOH] acid vapours, for short exposure times. The techniques used were gravimetric analysis, scanning electron microscopy (SEM and X-ray diffraction (XRD.

    Es frecuente la corrosión del cobre en presencia de ácidos orgánicos volátiles. Así, por ejemplo, se conoce que, en los equipos de aire acondicionado se producen fallos por corrosión en los tubos de cobre, ocasionada por los ácidos orgánicos volátiles desprendidos por los aceites. Otro caso frecuente es la corrosión de objetos de cobre ocasionada por los ácidos que desprenden los materiales utilizados en el embalaje, madera y resinas, entre otros. En esta comunicación se presentan los resultados de corrosión del cobre expuestos al 100% de humedad relativa y a diferentes concentraciones (10-300 ppm de los ácidos fórmico [HCOOH], acético [CH3COOH], propiónico [CH3CH2COOH] y butírico [CH3(CH22COOH] en cortos tiempos de exposición. Se utilizaron las técnicas gravimétricas, microscopía electrónica de barrido (SEM y difracción de rayos X (XRD.

  1. Dosimetric and radiobiological comparison of Forward Tangent Intensity Modulated Radiation Therapy (FT-IMRT) and Volumetric Modulated Arc Therapy (VMAT) for early stage whole breast cancer

    Science.gov (United States)

    Moshiri Sedeh, Nader

    Intensity Modulated Radiation Therapy (IMRT) is a well-known type of external beam radiation therapy. The advancement in technology has had an inevitable influence in radiation oncology as well that has led to a newer and faster dose delivery technique called Volumetric Modulated Arc Therapy (VMAT). Since the presence of the VMAT modality in clinics in the late 2000, there have been many studies in order to compare the results of the VMAT modality with the current popular modality IMRT for various tumor sites in the body such as brain, prostate, head and neck, cervix and anal carcinoma. This is the first study to compare VMAT with IMRT for breast cancer. The results show that the RapidArc technique in Eclipse version 11 does not improve all aspects of the treatment plans for the breast cases automatically and easily, but it needs to be manipulated by extra techniques to create acceptable plans thus further research is needed.

  2. Differences in PM{sub 10} concentrations measured by {sup {beta}}-gauge monitor and hi-vol sampler

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C.T.; Tsai, C.J. [National Chiao Tung University, Hsinchu (China). Institute of Environmental Engineering; Lee, C.T.; Chang, S.Y. [National Central University, Chungli, Taiwan (China). Institute of Environmental Engineering; Cheng, M.T. [National Chung Hsin University, Taichung, Taiwan (China). Institute of Environmental Engineering; Chein, H.M. [Industrial Technology Research Institute, Hsin Chu, Taiwan (China)

    2001-07-01

    In this paper, differences between the 24-h average PM{sub 10} concentrations of Wedding {sup {beta}}-gauge monitor and Andersen or Wedding hi-vol sampler were studied. When the deliquescent point is not exceeded, PM{sub 10} concentrations of the {sup {beta}}-gauge are close to those of the manual samplers. The ratio of {sup {beta}}-gauge PM{sub 10} to Andersen PM{sub 10} and Wedding PM{sub 10} is 1.08{+-}0.06 and 1.09{+-}0.12, respectively. However, when the deliquescent point is exceeded, water absorption by the inorganics of aerosols leads to higher PM{sub 10} concentrations of the {sup {beta}}-gauge compared to those of the manual sampler. The ratio of {sup {beta}}-gauge PM{sub 10} to Andersen PM{sub 10} and Wedding PM{sub 10} is 1.21{+-}0.22 and 1.27{+-}0.15, respectively. However, due to evaporation of water from the aerosols collected on the filter tape of the {sup {beta}}-gauge, differences in PM{sub 10} concentrations are much less than theoretically calculated. (author)

  3. Técnicas de aislamiento y concentración de volátiles de aceites vegetales

    Directory of Open Access Journals (Sweden)

    Morales, M. T.

    1992-06-01

    Full Text Available One of the methods for food flavor evaluation is the analysis of volatile components. First step in this kind of analysis Is the isolation and concentration of volatiles. A review is carried out about different techniques applied in foods and especially in vegetable oils. Very different methods have been used, an explication of each one with its different cases are presented. Likewise the applications carried out in vegetable oils during last years are discussed.

    Uno de los métodos de evaluación del flavor de los alimentos consiste en la determinación de sus componentes volátiles. La primera etapa necesaria para realizar este tipo de análisis es el aislamiento y concentración de los mismos. Se ha realizado una revisión bibliográfica sobre las diferentes técnicas utilizadas para este fin en diferentes alimentos y especialmente en aceites vegetales. Los métodos utilizados son muy diversos, se ofrece una explicación de cada uno de ellos considerando las diferentes variantes existentes. Asimismo se detallan las aplicaciones realizadas en aceites vegetales durante los últimos años.

  4. Self-organizing maps and VolSurf approach to predict aldose reductase inhibition by flavonoid compounds

    Directory of Open Access Journals (Sweden)

    Luciana Scotti

    2011-02-01

    Full Text Available Aldose Reductase (AR is the polyol pathway key enzyme which converts glucose to sorbitol. High glucose availability in insulin resistant tissues in diabetes leads into an accumulation of sorbitol, which has been associated with typical chronic complications of this disease, such as neuropathy, nephropathy and retinopathy. In this study, 71 flavonoids AR inhibitors were subjected to two methods of SAR to verify crucial substituents. The first method used the PCA (Principal Component Analysis to elucidate physical and chemical characteristics in the molecules that would be essential for the activity, employing VolSurf descriptors. The rate obtained explained 53% of the system total variance and revealed that a hydrophobic-hydrophilic balance in the molecules is required, since very polar or nonpolar substituents decrease the activity. Artificial Neural Networks (ANNs was also employed to determine key substituents by evaluating substitution patterns, using NMR data. This study had a high success rate (85% accuracy in the training set and 88% accuracy in the test set and showed polihydroxilations are essential for high activity and methoxylations and glicosilations primarily at positions C7, C3' and C4' decrease the activity.

  5. Buffer AVL Alone Does Not Inactivate Ebola Virus in a Representative Clinical Sample Type.

    Science.gov (United States)

    Smither, Sophie J; Weller, Simon A; Phelps, Amanda; Eastaugh, Lin; Ngugi, Sarah; O'Brien, Lyn M; Steward, Jackie; Lonsdale, Steve G; Lever, Mark S

    2015-10-01

    Rapid inactivation of Ebola virus (EBOV) is crucial for high-throughput testing of clinical samples in low-resource, outbreak scenarios. The EBOV inactivation efficacy of Buffer AVL (Qiagen) was tested against marmoset serum (EBOV concentration of 1 × 10(8) 50% tissue culture infective dose per milliliter [TCID50 · ml(-1)]) and murine blood (EBOV concentration of 1 × 10(7) TCID50 · ml(-1)) at 4:1 vol/vol buffer/sample ratios. Posttreatment cell culture and enzyme-linked immunosorbent assay (ELISA) analysis indicated that treatment with Buffer AVL did not inactivate EBOV in 67% of samples, indicating that Buffer AVL, which is designed for RNA extraction and not virus inactivation, cannot be guaranteed to inactivate EBOV in diagnostic samples. Murine blood samples treated with ethanol (4:1 [vol/vol] ethanol/sample) or heat (60°C for 15 min) also showed no viral inactivation in 67% or 100% of samples, respectively. However, combined Buffer AVL and ethanol or Buffer AVL and heat treatments showed total viral inactivation in 100% of samples tested. The Buffer AVL plus ethanol and Buffer AVL plus heat treatments were also shown not to affect the extraction of PCR quality RNA from EBOV-spiked murine blood samples.

  6. Clinical Research and Clinical Trials

    Science.gov (United States)

    ... NICHD Publications Data Sharing and Other Resources Research Clinical Trials & Clinical Research Skip sharing on social media links ... health care providers, and researchers. Find NICHD-Supported Clinical Trials Use this link to find a list of ...

  7. Clinical Competence/Clinical Credibility.

    Science.gov (United States)

    Goorapah, David

    1997-01-01

    In interviews with 10 nurse teachers and 10 clinicians, respondents could describe clinical competence more fluently than clinical credibility. Responses raised the question of whether nursing teachers must be clinically competent/credible to teach nursing. (SK)

  8. Volúmenes molares parciales de transferencia de la benzocaína desde mezclas agua-etanol hasta etanol absoluto a 25.0 °c

    OpenAIRE

    Ávila, Carolina; Martinez, Fleming

    2008-01-01

    En el presente trabajo se presentan los volúmenes molares parciales de transferencia a dilución infinita del anestésico local benzocaína (BZC) desde algunos medios acuoso-etanólicos hasta el etanol puro, obtenidos a partir de los valores de volúmenes molares aparentes en función de la concentración determinados a 25.0 ºC, en mezclas agua-etanol de fracción molar 0.2 y 0.5 de etanol, y en etanol absoluto, a diferentes concentraciones de BZC desde 0.010 hasta 0.100 mol-L-1. Según los resultados...

  9. Alelopatia de extratos voláteis na germinação de sementes e no comprimento da raiz de alface

    OpenAIRE

    Alves,Maria da Conceição Sampaio; Medeiros Filho,Sebastião; Innecco,Renato; Torres,Salvador Barros

    2004-01-01

    O objetivo deste trabalho foi identificar possíveis efeitos alelopáticos de extratos voláteis de óleos essenciais na germinação e no comprimento da raiz de plântulas de alface. Foram utilizadas cinco concentrações de cada óleo (0,0, 0,001, 0,01, 0,1 e 1,0%, v/v), em delineamento inteiramente casualizado, com quatro repetições de 25 sementes de alface. Os extratos voláteis de óleos essenciais de canela, alecrim-pimenta, capim-citronela e alfavaca-cravo evidenciaram potencialidades alelopáticas...

  10. Dislocation Behavior in ZrC Particles during Elevated Temperature Compressive Deformation of a 30 vol.% ZrCp/W Composite

    Institute of Scientific and Technical Information of China (English)

    Taiquan Zhang; Qingchang Meng; Yujin Wang; Yu Zhou; Guiming Song

    2011-01-01

    A 30 vol.% ZrCP/W composite has been deformed in compression in the temperature range of 1200-1600℃.Dislocation nucleation mechanism in ZrC particles is discussed by analyzing the harmonious deformation between tungsten-matrix and ZrC particles. Thermal activation apparently increases the mobility of screw segments, resulting in the formation of many kinetics jogs and thermodynamics jogs above 1300℃. The formation mechanisms of the dislocation configurations are studied.

  11. AGARD Flight Test Series. Volume 10. Weapon Delivery Analysis and Ballistic Flight Testing (L’Analyse du Largage d’Armes et les en Vol Balistique).

    Science.gov (United States)

    1992-07-01

    de ce volume figure ci-dessous. LAGARD peut etre tier que ces personnes competentes aient bien voulu accepter de partager leurs connaissances et...de travail sur les techniques des essais en vol a ete recree pour mener ä bien cette täche. Les monographies dans cette serie (a l’exception de la AG...DOIVENT ETRE ADRESSEES DIRECTEMENT AU SERVICE NATIONAL TECHNIQUE DE ^INFORMATION (NTIS) DONT LADRESSE SUIT. National Technical Information Service

  12. Volátiles generados por hidrólisis enzimática de glicósidos de hojas de lulo (Solanum quitoense L.

    Directory of Open Access Journals (Sweden)

    Carolina Osorio R.

    2010-07-01

    Full Text Available La fracción glicosídica de hojas de lulo (Solanum quitoense L. fue obtenida por adsorción sobre Amberlita XAD-2 y posterior elución con metanol. Los glicósidos así extraídos se hidrolizaron enzimáticamente con una glicosidasa no selectiva (Rohapect D5-L y las agliconas (volátiles enlazados glicosídicamente producidas fueron caracterizadas químicamente por CGAR (cromatografía de gases de alta resolución, CGAR-EM (cromatografía de gases de alta resolución acoplada a espectrometría de masas y analizadas sensorialmente (nota olfativa por CGAR-O (cromatografía de gases de alta resolución acoplada a olfatometría. Se detectaron en total 25 compuestos volátiles y de ellos, se identificaron 21, los cuales representan el 90 % de todas las agliconas generadas. Los volátiles identificados presentaron diversas estructuras químicas que pueden agruparse en Ci3-norisoprenoides (38.1 %, 15 mg/kg hojas, compuestos aromáticos (30.5 %, alcoholes monoterpénicos (12.3 % y compuestos alifáticos Cg (9.3 %. El extracto de volátiles producido por hidrólisis enzimática presentó un olor a verde amaderado agradable, con fuertes notas dulces parecidas a la miel.

  13. Fluorescence Microscopy and Fluorescent Probes, Vol. 2, Edited by Jan Slavík 1998. Plenum Press, New York and London. 292 pages. (hardback, $95.00).

    Science.gov (United States)

    Herman, Brian

    1999-03-01

    In June of 1995, the first conference on Fluorescent Microscopy and Fluorescent Probes was held in the beautiful city of Prague in the Czech Republic and the proceedings of that meeting were published by Plenum Press in 1996 (Fluorescence Microscopy and Fluorescent Probes, Vol. 1, edited by Jan Slavík). Based on the success of the first conference, a second conference was held two years later again in Prague, and this book is the proceedings of that meeting.

  14. The Gunite and Associated Tanks Remediation Project Tank Waste Retrieval Performance and Lessons Learned, vol. 2 [of 2

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, BE

    2003-10-07

    The Gunite and Associated Tanks (GAAT) Remediation Project was the first of its kind performed in the United States. Robotics and remotely operated equipment were used to successfully transfer almost 94,000 gal of remote-handled transuranic sludge containing over 81,000 Ci of radioactive contamination from nine large underground storage tanks at the Oak Ridge National Laboratory (ORNL). The sludge was transferred with over 439,000 gal of radioactive waste supernatant and {approx}420,500 gal of fresh water that was used in sluicing operations. The GAATs are located in a high-traffic area of ORNL near a main thoroughfare. Volume 1 provides information on the various phases of the project and describes the types of equipment used. Volume 1 also discusses the tank waste retrieval performance and the lessons learned during the remediation effort. Volume 2 consists of the following appendixes, which are referenced in Vol. 1: A--Background Information for the Gunite and Associated Tanks Operable Unit; B--Annotated Bibliography; C--GAAT Equipment Matrix; D--Comprehensive Listing of the Sample Analysis Data from the GAAT Remediation Project; and E--Vendor List for the GAAT Remediation Project. The remediation of the GAATs was completed {approx}5.5 years ahead of schedule and {approx}$120,435K below the cost estimated in the Remedial Investigation/Feasibility Study for the project. These schedule and cost savings were a direct result of the selection and use of state-of-the-art technologies and the dedication and drive of the engineers, technicians, managers, craft workers, and support personnel that made up the GAAT Remediation Project Team.

  15. Een vat vol organismen

    NARCIS (Netherlands)

    Vuuren, van A.M.

    2010-01-01

    Een laag melkvetgehalte, dunne mest, een lage voeropname en klauwproblemen bij melkvee worden te gemakkelijk toegeschreven aan stoornissen in de pens. Ook het advies om dan ‘prik’ bij te voeren is een te eenvoudige voorstelling van zaken bij het ontstaan van fermentatiestoornissen.

  16. Apache, Vol. I.

    Science.gov (United States)

    Bodiroga, Ronald, Comp.; And Others

    The short stories, poems, and cultural descriptions about American Indians (volume 1 of two) are the result of a combined effort of the 7th grade students of Rice School District (Sacaton, Arizona), their teacher, and the parents and friends of the students of the San Carlos Apache Indian Reservation (Arizona). The 24 student contributors prepared…

  17. Apache, Vol. II.

    Science.gov (United States)

    Bodiroga, Ronald, Comp.; And Others

    The short stories, poems, songs, and cultural descriptions about American Indians (volume 2 of two) are the result of a combined effort of the 7th grade students of Rice School District (Sacaton, Arizona), their teacher, and the parents and friends of the students of the San Carlos Apache Indian Reservation (Arizona). The 24 student contributors…

  18. Mathematics, Vol. 2.

    Science.gov (United States)

    Bureau of Naval Personnel, Washington, DC.

    The second of three volumes of a mathematics training course for Navy personnel, this document contains material primarily found at the college level. Beginning with logarithms and trigonometry, the text moves into vectors and static equilibrium (physics). Coordinate geometry, conic sections, and the tangents, normals, and slopes of curves follow.…

  19. Vibration Theory, Vol. 4

    DEFF Research Database (Denmark)

    Iwankiewicz, R.; Nielsen, Søren R. K.

    This text is based on the lecture notes for the courses on advanced methods in stochastic dynamics of non-linear systems taught in November 1994, February 1995 and December 1997 for Ph.D. students at the Department of Building Technology and Structural Engineering at Aalborg University and in 1999...... for postgraduate students and academic staff members at the school of Mechanical Engineering of the University of the Witwatersrand, Johannesburg. The book covers, in authors belief, the most important methods for the analyse of non-linear mechanical, or structural, systems. A large part of the methods covered...

  20. MONTHLY COACH VOL.5

    Institute of Scientific and Technical Information of China (English)

    Zhu; Jie(翻译); Hideyo; Fukuda(摄影); Tesuya; Yogi(摄影)

    2006-01-01

    有关COACH的新品以及一些内幕新闻都会连载于这一板块。本期,将由优子来扮演新闻记者,为我们介绍COACH的新品。这一季的新款可爱又实用,绝对会受办公室女孩的青睐!

  1. Vibration Theory, Vol. 3

    DEFF Research Database (Denmark)

    Nielsen, Søren R. K.

    The present textbook has been written based on previous lecture notes for a course on stochastic vibration theory that is being given on the 9th semester at Aalborg University for M. Sc. students in structural engineering. The present 4th edition of this textbook on linear stochastic vibration...

  2. Vibration Theory, Vol. 3

    DEFF Research Database (Denmark)

    Nielsen, Søren R. K.

    The present textbook has been written based on previous lecture notes for a course on stochastic vibration theory that is being given on the 9th semester at Aalborg University for M. Sc. students in structural engineering. The present 2nd edition of this textbook on linear stochastic vibration th...

  3. Clinical Trials

    Science.gov (United States)

    Clinical trials are research studies that test how well new medical approaches work in people. Each study answers ... prevent, screen for, diagnose, or treat a disease. Clinical trials may also compare a new treatment to a ...

  4. Radiobiological modeling with MarCell software

    Energy Technology Data Exchange (ETDEWEB)

    Hasan, J.S.; Jones, T.D. [Oak Ridge National Lab., TN (United States). Health Sciences Research Div.

    1999-01-01

    A nonlinear system of differential equations that models the bone marrow cellular kinetics associated with radiation injury, molecular repair, and compensatory cell proliferation has been extensively documented. Recently, that model has been implemented as MarCell, a user-friendly MS-DOS computer program that allows users with little knowledge of the original model to evaluate complex radiation exposure scenarios. The software allows modeling with the following radiations: tritium beta, 100 kVp X, 250 kVp X, 22 MV X, {sup 60}Co, {sup 137}Cs, 2 MeV electrons, triga neutrons, D-T neutrons, and 3 blends of mixed-field fission radiations. The possible cell lineages are stem, stroma, and leukemia/lymphoma, and the available species include mouse, rat, dog, sheep, swine, burro, and man. An attractive mathematical feature is that any protracted protocol can be expressed as an equivalent prompt dose for either the source used or for a reference, such as 250 kVp X rays or {sup 60}Co. Output from MarCell includes: risk of 30-day mortality; risk of cancer and leukemia based either on cytopenia or compensatory cell proliferation; cell survival plots as a function of time or dose; and 4-week recovery kinetics following treatment. In this article, the program`s applicability and ease of use are demonstrated by evaluating a medical total body irradiation protocol and a nuclear fallout scenario.

  5. Microstructure, Mechanical Properties, and Two-Body Abrasive Wear Behavior of Cold-Sprayed 20 vol.% Cubic BN-NiCrAl Nanocomposite Coating

    Science.gov (United States)

    Luo, Xiao-Tao; Yang, Er-Juan; Shang, Fu-Lin; Yang, Guan-Jun; Li, Chen-Xin; Li, Chang-Jiu

    2014-10-01

    20 vol.% cubic boron nitride (cBN) dispersoid reinforced NiCrAl matrix nanocomposite coating was prepared by cold spray using mechanically alloyed nanostructured composite powders. The as-sprayed nanocomposite coating was annealed at a temperature of 750 °C to enhance the inter-particle bonding. Microstructure of spray powders and coatings was characterized. Vickers microhardness of the coatings was measured. Two-body abrasive wear behavior of the coatings was examined on a pin-on-disk test. It was found that, in mechanically alloyed composite powders, nano-sized and submicro-sized cBN particles are uniformly distributed in nanocrystalline NiCrAl matrix. Dense coating was deposited by cold spray at a gas temperature of 650 °C with the same phases and grain size as those of the starting powder. Vickers hardness test yielded a hardness of 1063 HV for the as-sprayed 20 vol.% cBN-NiCrAl coating. After annealed at 750 °C for 5 h, unbonded inter-particle boundaries were partially healed and evident grain growth of nanocrystalline NiCrAl was avoided. Wear resistance of the as-sprayed 20 vol.% cBN-NiCrAl nanocomposite coating was comparable to the HVOF-sprayed WC-12Co coating. Annealing of the nanocomposite coating resulted in the improvement of wear resistance by a factor of ~33% owing to the enhanced inter-particle bonding. Main material removal mechanisms during the abrasive wear are also discussed.

  6. Un esquema de volúmenes finitos de alto orden para las ecuaciones de aguas someras con topografía y áreas secas

    OpenAIRE

    Gallardo Molina, José María; Castro Díaz, Manuel Jesús; Parés Madroñal, Carlos

    2007-01-01

    Presentamos un esquema de volúmenes finitos para la resolución de las ecuaciones de aguas someras con término fuente debido a la topografía del fondo. Se trata de un esquema de alto orden, bien equilibrado y capaz de afrontar situaciones en las que aparecen zonas secas. El esquema se ha desarrollado en un marco no conservativo general, y se basa en reconstrucciones hiperbólicas de estados. El tratamiento de situaciones seco/mojado se lleva a cabo mediante la resolución de problemas de Rie...

  7. Pocket book of the metal trade. Vol. 1. Metals and trading conditions. 11. rev. ed.; Taschenbuch des Metallhandels. Bd. 1. Metalle und Handelsbedingungen

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, Ralf (ed.); Dietz, Ferdinand; Kammer, Catrin; Mohr, Heinz; Zocher, Nadine

    2008-07-01

    Vol. 1 of the pocket book on metals and trading conditions comprises the following chapters: 1. Metal, a raw material; 2. Metal stock exchanges; 3. Trading conditions and standards; 4. Addresses, organisations, associations; 5. Metals dictionary D-E-F; 6. List of commodities for external trading; 7. Statistics (prices, production, consumption). [German] Der erste Band ueber Metalle und Handelsbedingungen ist in folgende Kapitel unterteilt: 1. Der Rohstoff Metall; 2. Die Metallboersen; 3. Handelsbedingungen/Normen; 4. Anschriften, Organisationen, Verbaende; 5. Metall Woerterbuch: Deutsch-Englisch Franzoesisch; 6. Warenverzeichnis fuer den Aussenhandel und 7. Statistik (Preis-, Produktions- und Verbrauchsstatistik).

  8. System Identification for Integrated Aircraft Development and Flight Testing (l’Identification des systemes pour le developpement integre des aeronefs et les essais en vol)

    Science.gov (United States)

    1999-03-01

    essais environ. Un outil d’optimisation param6trique IDLATNL a donc 6t6 naturellement d~velopp6 pour aider 5. IDLATNL Fing~nieur A r~soudre ce probl~me...support h de nombreux essais en vol sous contrat des Services Officiel Franqais (SPA6). 3. CAPTEURS Ce dispositif experimental a W utilis6 dans le...proviennent d’une travaillant dans le domaine fr~quentiel, fournit une centrale h inertic et de capteurs sp~cifiques cellule en cc qui estimation des

  9. Literature study of the radiobiological parameters of Caesium-137 required for evaluating internal irradiation doses as a function of age; Etude bibliographique des parametres radiobiologiques du cesium-137 necessaires a l'evaluation des doses d'irradiation interne en fonction de l'age

    Energy Technology Data Exchange (ETDEWEB)

    Garnier, A. [Commissariat a l' Energie Atomique, 92 - Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    This document reassembles information published in scientific literature on radiobiological parameters of Cs-137, necessary for the estimate of the internal irradiation dose of man according to his age (during growth). The data are completed by a commented review of the mathematical models, proposed in order to value the irradiation doses from ingested cesium and the biological parameters. (author) [French] Ce document rassemble les informations publiees dans la litterature scientifique, concernant les parametres radiobiologiqueo du cesium-137, necessaires a l'evaluation des doses d'irradiation interne de l'homme en fonction de l'age. Ces donnees sont completees par une revue commentee des modeles mathematiques proposes en vue de l'evaluation des doses d'irradiation a partir des quantites de cesium ingerees et des parametres biologiques. (auteur)

  10. Study of the Clinical Proton Beam Relative Biological Effectiveness at the JINR Phasotron, Dubna

    CERN Document Server

    Vitanova, A; Gaevskii, V N; Molokonov, A G; Spurny, F; Fadeeva, T A; Shmakova, N L

    2002-01-01

    Proton clinical beams contain particles with high linear energy transfer (LET). Secondary heavy charged particles produced from nuclear interactions and degraded protons at the Bragg peak region are particles with high LET. These particles could enhance the Relative Biological Effectiveness (RBE) of the proton beam. We have carried out two radiobiological experiments to investigate the RBE of 150 MeV clinical proton beam. The irradiation of the Chinese Hamster V79 cells were performed at two points of the depth-dose distribution - at the beam entrance and at the Bragg peak. The contribution of the high LET particles to dosimetric and microdosimetric characteristics in the various depth of proton beam was also experimentally studied using the CR-39 track etched detectors. The LET spectra between 10 and 700 keV/{\\mu}m were measured by means of track detectors and the automatic optical image analyzer LUCIA-II. The relative contribution of the high LET particles to ab! sorbed dose increases from several per cent ...

  11. Clinical Trials

    Science.gov (United States)

    ... they are receiving. Other clinical trials involve a crossover design, where participants are randomly assigned to take a new treatment, a treatment already in use, and/or a placebo for a specified time ... If I am involved in a "crossover" clinical trial, can I go back to the ...

  12. Composição de voláteis e perfil de aroma e sabor de méis de eucalipto e laranja

    Directory of Open Access Journals (Sweden)

    Bastos Deborah Helena Markowicz

    2002-01-01

    Full Text Available Neste trabalho foram analisados os compostos voláteis de amostras de mel de eucalipto e laranja colhidos nos estados de São Paulo e de Minas Gerais. O isolamento dos voláteis foi realizado empregando-se uma técnica de ''headspace'' dinâmico, a separação efetuada por cromatografia gasosa de alta resolução e a identificação por espectrometria de massas, Índices de Kovats e padrões, quando disponíveis. Foram identificados no mel de laranja o benzaldeído, o óxido cis de linalol, n-heptanal, 6-metil-5-hepten-2-ona, octanal e fenilacetaldeído, e em mel de eucalipto, o nonanal, 2-heptanona, 2-heptanol, octanol e nonanol. A caracterização sensorial desses méis foi obtida por Análise Descritiva Quantitativa e a aplicação de Análise dos Componentes Principais aos dados revelou que os descritores ''queimado'' e ''sabor residual'' caracterizam o mel de eucalipto, enquanto ''floral'' e ''cera'' caracterizam o mel de laranja. Entre os compostos identificados, o nonanal e o nonanol apresentaram contribuição sensorial importante ao mel de eucalipto, enquanto o fenilacetaldeído e o benzaldeído foram relacionados com os principais descritores do mel de laranja.

  13. Clinical Research

    DEFF Research Database (Denmark)

    Christensen, Irene

    2016-01-01

    This paper is about the logic of problem solving and the production of scientific knowledge through the utilisation of clinical research perspective. Ramp-up effectiveness, productivity, efficiency and organizational excellence are topics that continue to engage research and will continue doing s...... for years to come. This paper seeks to provide insights into ramp-up management studies through providing an agenda for conducting collaborative clinical research and extend this area by proposing how clinical research could be designed and executed in the Ramp- up management setting....

  14. Clinical photography.

    Science.gov (United States)

    Jakowenko, Janelle

    2009-01-01

    Digital cameras, when used correctly, can provide the basis for telemedicine services. The increasing sophistication of digital cameras, combined with the improved speed and availability of the Internet, make them an instrument that every health-care professional should be familiar with. Taking satisfactory images of patients requires clinical photography skills. Photographing charts, monitors, X-ray films and specimens also requires expertise. Image capture using digital cameras is often done with insufficient attention, which can lead to inaccurate study results. The procedures in clinical photography should not vary from camera to camera, or from country to country. Taking a photograph should be a standardised process. There are seven main scenarios in clinical photography and health professionals who use cameras should be familiar with all of them. Obtaining informed consent prior to photography should be a normal part of the clinical photography routine.

  15. Clinical Investigation.

    Science.gov (United States)

    1979-09-30

    Hiller, D.A., Elliott, J.P.: Tubal Ligation Syndrome Myth or Reality. Presented: Armed Forces Division of ACOG, New Orleans, Louisiana, October 1977...Molecular Weight Immunoreactive Glucagon Levels in Patients with the Post Prandial Syndrome . (Abst.) Western Society for Clinical Research, 1979. (3...Glucagon Levels in Patients witl the Post Prandial Syndrome . Presented: Western Society Meetings, Western Society for Clinical Research, February 1979. (3

  16. Clinical supervision.

    Science.gov (United States)

    Goorapah, D

    1997-05-01

    The introduction of clinical supervision to a wider sphere of nursing is being considered from a professional and organizational point of view. Positive views are being expressed about adopting this concept, although there are indications to suggest that there are also strong reservations. This paper examines the potential for its success amidst the scepticism that exists. One important question raised is whether clinical supervision will replace or run alongside other support systems.

  17. Compostos voláteis de três cultivares de manga (Mangifera indica L. Volatile composition of three cultivars of mango (Mangifera indica L.

    Directory of Open Access Journals (Sweden)

    M.R.B. Franco

    2004-06-01

    Full Text Available Os compostos voláteis de três cultivares de manga (Haden, Tommy-Atkins e Keitt procedentes do Estado de São Paulo, foram isolados por uma técnica de headspace dinâmico, envolvendo sucção em polímero poroso. A separação da mistura complexa de voláteis foi efetuada por cromatografia gasosa de alta resolução. Alguns compostos voláteis foram identificados por cromatografia gasosa-espectrometria de massas e índices de Kovats. Os hidrocarbonetos monoterpênicos foram os compostos mais abundantes no headspace das amostras. Car-3-eno foi o componente majoritário dos cultivares Haden e Keitt, enquanto a Tommy-Atkins mostrou predominância de car-3-eno e alfa-pineno. Outros compostos identificados foram alfa-fencheno, alfa-canfeno, p-cimeno, beta-mirceno, beta-felandreno, limoneno, alfa-terpinoleno, beta-cariofileno e alfa-humuleno. Os três lotes analisados para cada cultivar mostraram grande homogeneidade, não havendo diferença significativa ao nível de 5%.The volatile compounds of three mango cultivars (Haden, Tommy-Atkins and Keitt, from the State of São Paulo, were isolated by a dynamic headspace technique involving suction on a porous polymer. The complex mixture of volatile compounds was separated by high-resolution gas chromatography. Some volatiles were identified by gas chromatography-mass spectrometry and Kovats Indices. The monoterpene hydrocarbons were the most abundant in the headspace of the fruits. Car-3-ene was the major component of the cultivars Haden and Keitt, while the Tommy Atkins mango exhibited predominance of two constituents, car-3-ene and alpha-pinene. Other identified compounds were alpha-fenchene, alpha-camphene, p-cimene, beta-mircene, beta-phellandrene, limonene, alpha-terpinolene, beta-caryophyllene e alpha-humulene. Samples of the same cultivar demonstrated great homogeneity, with no statistically significant difference being observed among the three lots analyzed for each cultivar.

  18. Substituting environmentally relevant flame retardants: assessment fundamentals. Vol. 1: results and summary overview; Erarbeitung von Bewertungsgrundlagen zur Substitution umweltrelevanter Flammschutzmittel. Bd. 1: Ergebnisse und zusammenfassende Uebersicht

    Energy Technology Data Exchange (ETDEWEB)

    Leisewitz, A.; Kruse, H.; Schramm, E.

    2001-04-01

    The study examines the status, trends and alternatives (substitution and reduction potentials) in the use of flame retardants in selected product sectors: construction; electronics and electrical engineering; rail vehicles; textiles/upholstery. In addition, the study characterises thirteen flame retardants in terms of material flows, applications and toxicology/ecotoxicology. Vol. I: Summary overview of flame retardant applications in Germany in 1999/2000; characterisation of 13 flame retardants in terms of substance properties and application-specific characteristics, range of applications and quantities; derivation of assessment fundamentals for flame retardants, focussing on toxicology/ecotoxicology, suitability for closed-loop substance management, and potential for substitution and reduction; summary assessment of 13 flame retardants; summary overview of flame retardant applications. Vol. II: Analysis of flame retardant applications (state of the art, trends, alternatives) in: unsaturated polyester (UP) resins (rail vehicles); polyurethane (PU) insulating foams and one component foams (OCF) (construction sector); plastics for generic uses in electronic and electrical equipment, in casings for electronic and electrical equipment and in printed circuit boards (electronics/electrical engineering); and in upholstery and mattresses (textile applications). Vol. III: Toxicological/ecotoxicological profiles of substances: Decabromodiphenyl oxide; Tetrabromobisphenol A; Bis[pentabromophenyl]ethane; Hexabromocyclodo-decane, Tris[chloropropyl]phosphate, Resorcinol-bis-diphenylphosphate; N-Hydroxymethyl-3-dimethylphosphonopropionamide, Red phosphorus, Ammonium polyphosphate, Melamin cyanurate, Aluminiumtrihydroxide, Sodium borate decahydrate, Antimony trioxide. (orig.) [German] Untersucht werden Stand, Trends und Alternativen (Substitutions- und Minderungspotentiale) beim Einsatz von Flammschutzmitteln (FSM) in ausgewaehlten Produkten aus: Baubereich, Elektrotechnik

  19. Clinical Investigation Program.

    Science.gov (United States)

    1987-09-30

    permanently following adverse reactions con- sisting of back pain, macular degeneration , elevated triglycerides, relo- cated to Eurooe, wanted to stop...Approach. Arch Otoloaryngology Vol 112, October e 1986. Speech-Language Rehabilitation Section Abkarian GG, Krappes T, King P: Enhancing Interaction in a...and secondary, and any adverse reactions. This continues to be the primary mode of rehabilitation of patients who have had cataract sur- gery, and

  20. Corrosion behavior of 6061/Al-15 vol. pct. SiC(p composite and the base alloy in sodium hydroxide solution

    Directory of Open Access Journals (Sweden)

    P.D. Reena Kumari

    2016-11-01

    Full Text Available The corrosion behavior of 6061/Al-15 vol. pct. SiC(p composite and 6061 Al base alloy was investigated in a sodium hydroxide solution. The electrochemical parameters were derived from potentiodynamic polarization and electrochemical impedance spectroscopic (EIS techniques. The results showed that the corrosion resistance of the composite was lower than that of the base alloy in selected corrosion media. The corrosion rates of both the composite and the base alloy increased with the increase in the concentration of sodium hydroxide and also with the increase in temperature. The surface morphology of the metal surface was investigated using scanning electron microscope (SEM. Activation energy was evaluated using Arrhenius equation, and enthalpy of activation and entropy of activation values were calculated using transition state equation.

  1. Volúmenes pulmonares normales en pacientes con fibrosis pulmonar idiopática y enfisema Normal lung volumes in patients with idiopathic pulmonary fibrosis and emphysema

    Directory of Open Access Journals (Sweden)

    Juan Pablo Casas

    2008-08-01

    Full Text Available La fibrosis pulmonar idiopática (FPI es una enfermedad que se caracteriza por presentar un compromiso pulmonar de tipo restrictivo, resultante de una reducción en la complacencia pulmonar secundaria a fibrosis difusa. En el enfisema, la pérdida de elasticidad pulmonar y el colapso de las vías aéreas periféricas generan obstrucción e hiperinflación. El efecto simultáneo que ambas enfermedades producen sobre la fisiología pulmonar no es del todo claro y se han descripto volúmenes pulmonares normales o casi normales. Presentamos 4 pacientes de sexo masculino de 64, 60, 73 y 70 años, con antecedentes de tabaquismo e historia de disnea progresiva, tres de ellos con grave limitación en su calidad de vida al momento de la consulta. En la tomografía de tórax de alta resolución todos los pacientes presentaban signos de enfermedad intersticial pulmonar avanzada, con cambios de tipo fibrótico con predominio basal y subpleural, que coexistían con enfisema centroacinar con predominio en lóbulos superiores. Uno de ellos tuvo confirmación diagnóstica de ambas condicioes por biopsia pulmonar a cielo abierto. En los cuatro pacientes la espirometría y volúmenes pulmonares fueron normales, pero tenían importante compromiso del intercambio gaseoso evaluado mediante el test de caminata de 6 minutos. Tres de los pacientes tenían hipertensión pulmonar grave diagnosticado por ecocardiograma. La presencia de volúmenes pulmonares normales no excluye un diagnóstico de fibrosis pulmonar idiopática en pacientes fumadores si coexisten evidencias tomográficas de enfisema. En estos pacientes el grado de compromiso funcional, determinado por la reducción de los volúmenes pulmonares, no debería ser considerado en la evaluación de la gravedad.Pulmonary function tests in idiopathic pulmonary fibrosis characteristically show a restrictive pattern, resulting from reduction of pulmonary compliance due to diffuse fibrosis. Conversely, an obstructive

  2. [CO2-stunning of slaughter pigs: effects on EEG, catecholamines and clinical reflexes].

    Science.gov (United States)

    Hartung, J; Nowak, B; Waldmann, K H; Ellerbrock, S

    2002-03-01

    Investigations were carried out on the response of slaughter pigs to CO2 stunning with two different gas concentrations (80 vol%, 90 vol%, 73 s) under practical conditions in a one gondola-dip-lift system. EEG measurements were performed and blood constituents such as catecholamines (adrenaline, nor-adrenaline) and lactate as well as clinical reactions (nasal septum and corneal reflex, heart beats) investigated. Special EEG-electrodes were adapted for the measurement on pigs and a mobile data logger was prepared for the use in the lairage of the slaughter house and in the stunning unit. The CO2 concentrations were measured continuously close to the head of the pigs when transported up and down in the stunning gondola. The results show that the technique is suited to monitor the effects of different CO2 gas concentrations on the EEG of the pigs under practical conditions. There is strong evidence that CO2 concentrations of 80 vol% applied over 70 s as required by law are not sufficient to stun pigs properly. A large part of the animals still showed typical reflexes when leaving the stunning pit. When an atmosphere of 90 vol% CO2 is applied, most animals are already dead before bleeding commences. This may create problems in respect to meat hygiene. The blood analysis revealed very high concentrations of catecholamines after stunning. The values for adrenaline and nor-adrenaline in the sticking blood rose by a factor of about 1000 as compared to the concentrations in blood samples taken in the lairage before stunning. It seems necessary to revise the current legislation on gas stunning and to look in greater detail in the effects of CO2 stunning on the welfare of slaughter pigs.

  3. [The French project ETOILE: review of clinical data for light ion hadrontherapy].

    Science.gov (United States)

    Pommier, P; Balosso, J; Bolla, M; Gérard, J P

    2002-12-01

    The Lawrence Berkeley Laboratory was the pioneer in light ions hadrontherapy with almost 2500 patients treated between 1957 and 1993 with Helium and Neon. The NIRS (National Institute For Radiological Science, Chiba, Japan) was the first dedicated medical centre for cancer with more than 1200 patients exclusively treated with carbon ion from 1994. A three-year 70 to 100% local control was reported for radio-resistant cancers, supporting the use of high LET particles. Hypo-fractionation was particularly explored for lung cancers and hepatocarcinoma (4 sessions only). Dose escalation studies demonstrated a tumour dose-effect and permitted to precise dose constraints for healthy tissues especially for the rectum. More than 140 patients were treated with carbon ion exclusively or associated with photons since 1997 in the GSI laboratory Gesellschaft Für Schwerionenforschung, Darmstadt, Germany). A very high local control was also obtained for radioresistant cancer of the base of the skull. Preliminary clinical data seem to confirm the expected therapeutic gain with light ions, due to their ballistic and radio-biological properties, and justify the European projects for the construction of dedicated medical facilities for cancers. The French "Etoile" project will be integrated in the European hadrontherapy network "Enlight", with the objectives to coordinate technologic, medical and economic features.

  4. Clinical Trials

    Science.gov (United States)

    ... and her initial results. Nueva Esperanza Para Las Enfermedades Del Corazón 09/23/2014 Milena tuvo un ... Story 09/23/2014 Nueva Esperanza Para Las Enfermedades Del Corazón 09/23/2014 Children and Clinical ...

  5. The evidence base for the use of internal dosimetry in the clinical practice of molecular radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Strigari, Lidia [Regina Elena National Cancer Institute, Laboratory of Medical Physics and Expert Systems, Rome (Italy); Konijnenberg, Mark [Erasmus MC, Department of Nuclear Medicine, Rotterdam (Netherlands); Chiesa, Carlo [Instituto Nazionale Tumori, Department of Nuclear Medicine, Milan (Italy); Bardies, Manuel [UMR 1037 INSERM / Universite Paul Sabatier, Centre de Recherche en Cancerologie de Toulouse, Toulouse (France); Du, Yong [Royal Marsden NHS Foundation Trust, Department of Nuclear Medicine and PET/CT, Sutton, London (United Kingdom); Gleisner, Katarina Sjoegreen [Medical Radiation Physics, Clinical Sciences, Lund (Sweden); Lassmann, Michael [University of Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany); Flux, Glenn [Royal Marsden NHS Foundation Trust and Institute of Cancer Research, Joint Department of Physics, Sutton (United Kingdom)

    2014-10-15

    Molecular radiotherapy (MRT) has demonstrated unique therapeutic advantages in the treatment of an increasing number of cancers. As with other treatment modalities, there is related toxicity to a number of organs at risk. Despite the large number of clinical trials over the past several decades, considerable uncertainties still remain regarding the optimization of this therapeutic approach and one of the vital issues to be answered is whether an absorbed radiation dose-response exists that could be used to guide personalized treatment. There are only limited and sporadic data investigating MRT dosimetry. The determination of dose-effect relationships for MRT has yet to be the explicit aim of a clinical trial. The aim of this article was to collate and discuss the available evidence for an absorbed radiation dose-effect relationships in MRT through a review of published data. Based on a PubMed search, 92 papers were found. Out of 79 studies investigating dosimetry, an absorbed dose-effect correlation was found in 48. The application of radiobiological modelling to clinical data is of increasing importance and the limited published data on absorbed dose-effect relationships based on these models are also reviewed. Based on National Cancer Institute guideline definition, the studies had a moderate or low rate of clinical relevance due to the limited number of studies investigating overall survival and absorbed dose. Nevertheless, the evidence strongly implies a correlation between the absorbed doses delivered and the response and toxicity, indicating that dosimetry-based personalized treatments would improve outcome and increase survival. (orig.)

  6. Preparación de una esencia de lulo (solanum vestissimun d. a partir del estudio de la contribución de los componentes volátiles al aroma de la fruta

    Directory of Open Access Journals (Sweden)

    J. Silva

    2010-05-01

    Full Text Available Los constituyentes volátiles del aroma del lulo (Solanum vestissimum D. fueron extraídos y caracterizados química y olfatométricamente, encontrándose que el aroma de esta fruta no es debida a unos pocos componentes sino a una mezcla compleja de 32 compuestos volátiles mayoritarios, de los cuales el butanoato de metilo, (E-2-butenoato de metilo, butanoato de etilo, (Z-3-hexenol, hexanoato de metilo, hexanoato de etilo, acetato de (Z-3-hexenilo, limoneno, 7- terpineneno, benzoato de metilo, lonalol y o-terpineol parecen contribuir de manera más efectiva a este exótico y delicioso aroma. Debido a que no se encontró un solo compuesto(s responsable de aroma típico de esta fruta, se utilizó el extracto completo de volátiles para preparar una buena esencia de lulo (utilizando como mejor matriz propilénglicol en solución acuosa al 10% y extracto de volátiles al 2%, la cual fue luego incorporada como aromatizante y saborizante en un helado de crema. El producto así preparado tuvo una gran aceptación por quienes lo consumieron

  7. AGARD Flight Test Instrumentation Series. Volume 1, Issue 2. Basic Principles of Flight Test Instrumentation Engineering (Introduction Generale aux Principles de Base de l’Instrumentation des Essais en Vol)

    Science.gov (United States)

    1994-03-01

    Vol. 15, 1982. 19. Torge , Wolfgang , Geodasie, Walter de Gruyter, Berlin, 1975. 20. "World Geodetic System 1984 (WGS84) - Auszug aus dem DMA...of 100 m/sec, for example, a time error of 10 msec may cause a position error of 1 m. 13.6 REFERENCES 13.1 Augath, Von Wolfgang and Klaus Kummer, "Die

  8. Clinical biochemistry

    Science.gov (United States)

    Alexander, W. C.; Leach, C. S.; Fischer, C. L.

    1975-01-01

    The objectives of the biochemical studies conducted for the Apollo program were (1) to provide routine laboratory data for assessment of preflight crew physical status and for postflight comparisons; (2) to detect clinical or pathological abnormalities which might have required remedial action preflight; (3) to discover as early as possible any infectious disease process during the postflight quarantine periods following certain missions; and (4) to obtain fundamental medical knowledge relative to man's adjustment to and return from the space flight environment. The accumulated data presented suggest that these requirements were met by the program described. All changes ascribed to the space flight environment were subtle, whereas clinically significant changes were consistent with infrequent illnesses unrelated to the space flight exposure.

  9. Clinical Studies

    DEFF Research Database (Denmark)

    Pallesen, Ulla

    and repair? Have new materials improved longevity? Are there still clinical and material problems to be solved? And what has the highest impact on longevity of posterior resin restorations – the material, the dentist, the patient or the tooth? These matters will be discussed on the basis of the literature......Within the last 25 years composite resin materials have in many countries successively replaced amalgam as a restorative for posterior teeth. Resin materials and bonding systems are continuously being improved by the manufactures, adhesive procedures are now included in the curriculum of most...... universities and practicing dentists restore millions of teeth throughout the World with composite resin materials. Do we know enough about the clinical performance of these restorations over time? Numerous in vitro studies are being published on resin materials and adhesion, some of them attempting to imitate...

  10. Memory clinics

    OpenAIRE

    Jolley, D; Benbow, S M; Grizzell, M

    2006-01-01

    Memory clinics were first described in the 1980s. They have become accepted worldwide as useful vehicles for improving practice in the identification, investigation, and treatment of memory disorders, including dementia. They are provided in various settings, the setting determining clientele and practice. All aim to facilitate referral from GPs, other specialists, or by self referral, in the early stages of impairment, and to avoid the stigma associated with psychiatric services. They bring ...

  11. Clinical practice

    OpenAIRE

    2011-01-01

    Cerebral palsy (CP) is the most common physical disability in early childhood. The worldwide prevalence of CP is approximately 2–2.5 per 1,000 live births. It has been clinically defined as a group of motor, cognitive, and perceptive impairments secondary to a non-progressive defect or lesion of the developing brain. Children with CP can have swallowing problems with severe drooling as one of the consequences. Malnutrition and recurrent aspiration pneumonia can increase the risk of morbidity ...

  12. Compuestos volátiles libres y enlazados glicosídicamente en la pulpa de la uva Caimarona (Pourouma cecropiifolia Mart. Compostos voláteis livres e enlaçados glicosídicamente na polpa da uva Caimarona (Pourouma cecropiifolia Mart.

    Directory of Open Access Journals (Sweden)

    Juliana Constanza Barrios Guio

    2010-03-01

    Full Text Available Los componentes volátiles presentes en la pulpa de la uva Caimarona se estudiaron mediante GC-MS. Éstos se extrajeron por tres técnicas: evaporación del aroma asistida con solvente (Solvent Assisted Flavour Evaporation SAFE, extracción continua líquido-líquido (LL y destilación por arrastre con vapor-extracción simultanea con solvente orgánico (DES. En general los componentes volátiles predominantes en la pulpa fueron alcoholes alifáticos y terpénicos. Las notas olfativas del extracto SAFE fueron descritas como floral tenue y verde herbal similares a las exhibidas por la pulpa fresca. Este extracto presentó como componentes mayoritarios linalol 1,2-propanodiol y salicilato de metilo. En contraste, el extracto LL presentó notas que recuerdan la uva pasa y el vino moscatel y sus componentes mayoritarios fueron el ácido acético, el salicilato de metilo y el 2,6-dimetil-2(Z,7-octadien-1,6-diol. El extracto DES fue descrito con notas fresca, floral, cereal y amargo y está constituido por un reducido número de componentes mostrando el efecto negativo de la temperatura en la extracción; sus componentes mayoritarios fueron 1,2-propanodiol, linalol y salicilato de metilo. Adicionalmente, los componentes volátiles mayoritarios liberados por hidrólisis enzimática (Rohapect D5L de los glicósidos de la pulpa fueron ácido acético, ácido benzoico y vainillina. Cabe destacar que aunque el linalol no se encontró entre las agliconas volátiles, se detectaron los dioles biogenéticamente relacionados: 3,7-dimetil-1,5-octadien-3,7-diol y los isómeros E y Z del 2,6-dimetil-2,7-octadien-1,6-diol.Os componentes voláteis presentes na polpa da uva Caimarona foram estudados mediante GC-MS. Estes foram extraídos por três técnicas: evaporação de aroma assistida com solvente (Solvent Assisted Flavour Evaporation SAFE, extração continua líquido-líquido (LL e destilação por arraste com vapor-extração simultânea com solvente org

  13. Differential diagnosis in pediatric radiology. Vol. 1. Skull, spine, skeleton; Differentialdiagnostik in der paediatrischen Radiologie. Bd. 1. Schaedel, Wirbelsaeule, Skelett

    Energy Technology Data Exchange (ETDEWEB)

    Ebel, K.D. [ed.; Willich, E. [ed.; Richter, E. [ed.; Benz-Bohm, G.; Bliesener-Harzheim, J.A.; Ebel, K.D.; Oestreich, A.E.; Reinwein, H.; Schaper, J.; Schumacher, R.; Stoever, B.

    1995-06-01

    The book presents in-depth material covering the full scope of tasks and problems of differential diagnostic radiology in children. The particular approach chosen by the authors provides information that will solve even the most difficult cases, guiding the reader on his way from radiographic findings to appropriate diagnosis. All radiographic findings have been characterized and classified and put into a tabulated system relating them to the relevant differential diagnosis. The system of reference adopted specifies a given lesion or disease by reference to the most significant diagnostic keywords obtained from anamnesis, clinical data, and further diagnostic evaluation. The tentative diagnosis is taken as the basis for further specification illustrated by the characteristic X-ray pictures and full-text descriptions. Almost all diagnoses are accompanied by a comprehensive image documentation obtained by all currently available imaging methods. (MG) [Deutsch] Das vorliegende Buch gibt einen kompletten Ueberblick ueeber die gesamte Bandbreite der Differentialdiagnostik in der Paediatrischen Radiologie und soll so auch in schwierigen Faeellen den Weg vom Roentgensymptom zur Diagnose ermoeglichen. Alle relevanten Roentgensymptome werden systematisch charakterisiert und die entsprechenden Differentialdiagnosen tabellarisch zusammengestellt. Jede Erkrankung wird durch Verweise auf die wichtigsten differentialdiagnostischen Stichworte aus Anamnese, Klinik und weiterfuehrende Diagnostik naeher eingegrenzt. Ausgehend von der Verdachtsdiagnose werden wegweisende Roentgenbefunde in Wort und Bild dargestellt. Fast alle erwaehnten Befunde werden durch Abbildungen unter Beruecksichtigung aller moderner bildgebenden Verfahren dokumentiert. (MG)

  14. What Are Clinical Trials?

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Clinical Trials What Are Clinical Trials? Past Issues / Fall 2010 Table of Contents Clinical ... conducted all the time. The Different Phases of Clinical Trials Clinical trials related to drugs are classified into ...

  15. Participating in Clinical Trials

    Science.gov (United States)

    ... this page please turn Javascript on. Participating in Clinical Trials About Clinical Trials A Research Study With Human Subjects A clinical ... to treat or cure a disease. Phases of Clinical Trials Clinical trials of drugs are usually described based ...

  16. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... Z > Participating in Clinical Trials: About Clinical Trials In This Topic About Clinical Trials Risks and Benefits ... of this page please turn Javascript on. Participating in Clinical Trials About Clinical Trials A Research Study ...

  17. Comportamiento en fluencia de un material compuesto de matriz metálica Al6061-15 vol % SiCw pulvimetalúrgico

    Directory of Open Access Journals (Sweden)

    González-Doncel, G.

    2005-12-01

    Full Text Available The creep behavior of a powder metallurgy (PM Al6061-15 vol % SiCw metal matrix composite has been studied. This behavior has been compared to that of 6061Al cast alloy and 6061Al PM alloy. The creep response of the PM unreinforced alloy is better than that of the cast 6061Al alloy. Similarly, the behavior of the composite is better than that of the PM unreinforced alloy. Two microstructural factors have been considered the responsible ones of this improvement. The first one is the dispersion of Al2O3 oxide particles of nanometric scale. The second one, is the presence of the SiC whisker reinforcement of micrometric scale. Despite the similar strengthening effect, the intrinsic nature of the reinforcing mechanism is, however, different for each type of particle due to the different microstructural scale.Se ha realizado un estudio de las propiedades en fluencia del material compuesto pulvimetalúrgico Al6061-15 vol % SiCw. Su comportamiento se ha comparado con el de la aleación Al6061 pulvimetalúrgica y la aleación Al6061 de colada. El comportamiento del material pulvimetalúrgico sin reforzar mejora respecto al del material de colada. Al mismo tiempo, el del material compuesto mejora respecto al comportamiento del material pulvimetalúrgico sin reforzar. Se consideran dos factores microestructurales como los principales responsables de la mejora de las propiedades en fluencia de este material compuesto. Por un lado, las partículas de Al2O3 de tamaño nanométrico y, por otro, las partículas de fibra corta cerámicas de SiC de tamaño micrométrico. Aunque ambos tipos de partículas dan lugar a un efecto de refuerzo similar, los mecanismos intrínsecos asociados a la presencia de estas partículas tienen una naturaleza diferente debido a la diferencia en la escala microestructural.

  18. Development of a single ion micro-irradiation facility for experimental radiobiology at cell level; Developpement d'une ligne d'irradiation microfaisceau en mode ion par ion pour la radiobiologie experimentale a l'echelle cellulaire

    Energy Technology Data Exchange (ETDEWEB)

    Barberet, Ph

    2003-10-01

    A micro-irradiation device has been developed for radiobiology applications at the scale of the cell. This device is based on an upgrade of an existing micro-beam line that was already able to deliver a 1 to 3 MeV proton or alpha beam of low intensity and whose space resolution is lower than 1 micrometer in vacuum. The important part of this work has been the development of an irradiation stage designed to fit on the micro-probe and able to deliver ions in the air with an absolute accuracy of a few micrometers. A program has been set up to monitor the complete irradiation line in testing and in automatic irradiation operating phases. Simulation tools based on Monte-Carlo calculations have been validated through comparisons with experimental data particularly in the field of spatial resolution and of the number of ions delivered. The promising results show the possibility in a near future to use this tool to study the response of cells to very low irradiation doses down to the extreme limit of one ion per cell.

  19. Clinical guidelines.

    Science.gov (United States)

    Uppal, Elaine

    2016-01-01

    This article is part of the Advancing practice series which is aimed at exploring practice issues in more depth, considering topics that are frequently encountered and facilitating the development of new insights. Elaine Uppal focuses on the importance of all midwives developing guideline writing skills to ensure that local, national and international midwifery/maternity guidelines are up to date, relevant and reflect midwifery knowledge alongside 'gold' standard evidence. The article aims to consider the development, use and critical appraisal of clinical guidelines. It will define and explain guidelines; discuss their development and dissemination; and consider issues relating to their use in practice. Techniques to critique and develop guidelines using the AGREE tool will be outlined in the form of practice challenges to be undertaken by the individual or in a group.

  20. 基于Asterisk的高校图书馆VolP语音服务研究%VoIP Voice Service of University Libraries Based on the Asterisk

    Institute of Scientific and Technical Information of China (English)

    王福; 李晋瑞; 闫利霞

    2012-01-01

    以美国Digium公司开发的一个开源软交换项目Asterisk为例,讨论高校图书馆开发VoIP语音呼叫系统的必要性和可行性。在此基础上对图书馆语音呼叫服务进行系统需求分析、系统的业务数据和对象的逻辑分析,最后通过案例分析说明Asterisk在图书馆的应用效果。%Asterisk is an open source project of soft switch developed by the Digium company in the United States of America. This paper discusses the necessity and feasibility that university libraries develop the VolP voice call system. Based on that, it analyzes the system demand, system data and logic of objects of library voice call service. At last, the paper illustrates the application of Asterisk in library network through the case study.

  1. Caracterización de especies de Tilia mediante perfiles cromatográficos en fase gaseosa de los componentes volátiles extraídos del vapor en equilibrio con el material vegetal ( "headspace analysis" )

    OpenAIRE

    Sala, Gabriela; Mandrile, Eloy L.; Cafferata, Lázaro F. R.

    1992-01-01

    Se han estudiado los componentes volátiles de brácteas y flores de 3 especies de Tilia (Tilo), por cromatografía gaseosa, utilizando una columna rellena con "Porapak Q" a fin de contribuir a su caracterización quimiotaxonómica. Se compararon las eficiencias relativas de los métodos de extracción de compuestos volátiles: destilación por arrastre con vapor de agua, destilación a presión reducida y de muestreo estático de la cámara ocupada por el vapor en equilibrio con el material a 80 "C ("Hea...

  2. A stupid plagiarism in the article « Ethnopharmacology and phytochemical screening of bioactive extracts of Limoniastrum feei ( plombagenaceae » Asian Journal of Natural & Applied Sciences, Vol. 2(1, 5-9, 2013.

    Directory of Open Access Journals (Sweden)

    A. CHERITI

    2013-11-01

    Full Text Available It’s well known that plagiarism is considered mis­conduct research, unethical, perturb and damage the integrity and knowledge of the scientific community. In addition that is a form of violation of copyright law and is therefore illegal. Whereas matching an integral article (Copy and paste from another scientific journal is a potential plagiarism qualified unjustified attitude and a stupid practice. The most striking case, is the copy and paste of our article published since 2012 in this journal (PhytoChem & BioSub Journal Vol. 6 N° 2, 83-87, 2012 by another “ scientists” - L. Ziane, H. A. Lazouni, A. Moussaoui, N. Hamidi - and published in Asian Journal of Natural & Applied Sciences, Vol. 2(1, 5-9, 2013. Thus, any one, authors or publisher not condemn and promote these practices should be automatically disqualified from scientific research.

  3. Salles, Sergio. Paul Ricoeur e o humanismo jurídico moderno: O reconhecimento do sujeito de direito. Études Ricoeuriennes / Ricoeur Studies vol. 2, no. 2 (2011: 106–117

    Directory of Open Access Journals (Sweden)

    ERRS ERRS

    2012-01-01

    Full Text Available As published, the authorship for this article is incorrect. Coauthor Hilda Helena Soares Bentes was omitted due to an editorial error. The correct citation is:Bentes, Hilda and Salles, Sergio. Paul Ricoeur e o humanismo jurídico moderno: O reconhecimento do sujeito de direito. Études Ricoeuriennes / Ricoeur Studies vol. 2, no. 2 (2011: 106–117.The online version reflects these changes.

  4. Constituintes voláteis de cafés "gourmet" e mole do cerrado do triângulo mineiro em função da torra

    Directory of Open Access Journals (Sweden)

    Nascimento Evandro Afonso do

    2003-01-01

    Full Text Available Neste trabalho foi estudada a variação da composição dos voláteis de dois cafés "gourmet" e de um café mole em função do grau de torrefação. Os cafés provenientes de Araguari, cerrado do Triângulo Mineiro, foram submetidos à torra americana (grãos marrons claros, média (grãos marrons e forte (grãos pretos e, em seguida, moídos e submetidos a uma destilação por arraste de vapor em contra-corrente com diclorometano. A análise de cromatografia gasosa acoplada à espectrometria de massas (CG-EM dos constituintes voláteis mostrou que piridina, pirazina e derivados, furfural e derivados são os principais constituintes voláteis dos cafés analisados. Mostrou ainda que não é possível diferenciar os três tipos de café pelos compostos dominantes (concentração acima de 1% no aroma. Foi observado também que a torra afeta sensivelmente os resultados, sendo que a torra americana, usada normalmente na prova da xícara para classificação sensorial de cafés, produz alguns voláteis de forte impacto no aroma que não aparecem na torra média nem na forte, além de apresentar concentrações dos componentes mais comuns muito diferentes daquelas observadas nas outras duas torras.

  5. A new and fast methodology to assess oxidative damage in cardiovascular diseases risk development through eVol-MEPS-UHPLC analysis of four urinary biomarkers.

    Science.gov (United States)

    Mendes, Berta; Silva, Pedro; Mendonça, Isabel; Pereira, Jorge; Câmara, José S

    2013-11-15

    In this work, a new, fast and reliable methodology using a digitally controlled microextraction by packed sorbent (eVol(®)-MEPS) followed by ultra-high pressure liquid chromatography (UHPLC) analysis with photodiodes (PDA) detection, was developed to establish the urinary profile levels of four putative oxidative stress biomarkers (OSBs) in healthy subjects and patients evidencing cardiovascular diseases (CVDs). This data was used to verify the suitability of the selected OSBs (uric acid-UAc, malondialdehyde-MDA, 5-(hydroxymethyl)uracil-5-HMUra and 8-hydroxy-2'-deoxyguanosine-8-oxodG) as potential biomarkers of CVDs progression. Important parameters affecting the efficiency of the extraction process were optimized, particularly stationary phase selection, pH influence, sample volume, number of extraction cycles and washing and elution volumes. The experimental conditions that allowed the best extraction efficiency, expressed in terms of total area of the target analytes and data reproducibility, includes a 10 times dilution and pH adjustment of the urine samples to 6.0, followed by a gradient elution through the C8 adsorbent with 5 times 50 µL of 0.01% formic acid and 3×50 µL of 20% methanol in 0.01% formic acid. The chromatographic separation of the target analytes was performed with a HSS T3 column (100 mm × 2.1 mm, 1.7 µm in particle size) using 0.01% formic acid 20% methanol at 250 µL min(-1). The methodology was validated in terms of selectivity, linearity, instrumental limit of detection (LOD), method limit of quantification (LOQ), matrix effect, accuracy and precision (intra-and inter-day). Good results were obtained in terms of selectivity and linearity (r(2)>0.9906), as well as the LOD and LOQ, whose values were low, ranging from 0.00005 to 0.72 µg mL(-1) and 0.00023 to 2.31 µg mL(-1), respectively. The recovery results (91.1-123.0%), intra-day (1.0-8.3%), inter-day precision (4.6-6.3%) and the matrix effect (60.1-110.3%) of eVol

  6. [Clinical research VI. Clinical relevance].

    Science.gov (United States)

    Talavera, Juan O; Rivas-Ruiz, Rodolfo

    2011-01-01

    Usually, in clinical practice the maneuver selected is the one that achieves a favorable outcome with a direct percentage of superiority of at least 10 %, or when the number needed to treat is approximately equal to 10. While this percentage difference is practical for estimating the magnitude of an association, we need to differentiate the impact measures (attributable risk, preventable fraction), measures of association (RR, OR, HR), and frequency measures (incidence and prevalence) applicable when the outcome is nominal. And we must identify ways to measure the strength of association and the magnitude of the association when the outcome variable is quantitative. It is not uncommon to interpret the measures of association as if they were impact measures. For example, for a RR of 0.68, it is common to assume a 32 % reduction of the outcome, but we must consider that this is a relative reduction, which comes from relations of 0.4/0.6, 0.04/0.06, or 0.00004/0.00006. However the direct reduction is 20 % (60 % - 40 %), 2 %, and 2 per 100,000, respectively. Therefore, to estimate the impact of a maneuver it is important to have the direct difference and/or NNT.

  7. Effects of CO2 pneumoperitoneum on blood flow vol-ume of abdominal organs of rabbits with controlled hem-orrhagic shock and liver impact injuries

    Institute of Scientific and Technical Information of China (English)

    ZHANG Lian-yang; ZHAO Song; LI Yong; MA Xiao-lin

    2009-01-01

    Objective: To investigate the effects of CO2 pneumo-peritoneum on blood flow volume of abdominal organs of rabbits with controlled hemorrhagic shock model and liver impact injuries.Methods: After controlled hemorrhagic shock and liver impact injuries, the rabbit model was established. Eighteen rabbits subjected to hemorrhagic shock and liver impact inju-ries were divided into 3 groups randomly according to the volume of lost blood: light hemorrhagic shock (blood loss volume was 10%, 6 ml/kg), moderate hemorrhagic shock (20%, 12 ml/kg) and severe hemorrhagic shock (40%, 22 ml/kg). Intraabdominal pressures of CO2 pneumoperitoneum was 10 mmHg. Color-labeled microspheres were used to mea-sure the blood flow volume of the liver, kidney and stomach before pneumoperitoneum at 30 minutes and 2 hours after pneumoperitoneum and 30 minutes after deflation. And the mortality and hepatic traumatic condition of rabbits were recorded.Results: Of the 18 rabbits, there were 9 with liver impact injuries at Grade Ⅰ, 8 at Grade Ⅱ and Ⅰ at Grade Ⅲ (according to AIS-2005). The mortality rate in light hemorrhagic shock group was 33.33%, and that in moderate or severe hemor-rhagic shock group was 100% within 30 minutes and 2 hours after pneumoperitoneum, respectively. The blood flow vol-ume in the organs detected decreased at 30 minutes under pneumoperitoneum in light and moderate hemorrhagic shock groups. At the same time, the blood flow volume of the liver in moderate hemorrhagic shock group decreased more sig-nificantly than that in light hemorrhagic shock group.Conclusions: The blood flow volume of abdominal organs in rabbits is decreased obviously under CO2 pneumoperitoneum, with fairly high mortality rate. It is be-lieved that CO2 pneumoperitoneum should cautiously be used in abdominal injury accompanied with hemorrhagic shock, especially under non-resuscitation conditions.

  8. The impact on the radiobiological effect of lung squamous cancer cell line H520 with prolonged fraction delivery time%照射时间延长对肺鳞癌细胞株H520放射生物效应的影响

    Institute of Scientific and Technical Information of China (English)

    李磊; 孟玲楠; 高纯子; 林珊; 李瑛; 韩波

    2013-01-01

    目的观察常规剂量分割照射模式下单次照射时间延长对肺癌细胞系H520放射生物效应的影响.方法 (1)肺鳞癌细胞株H520离体培养,分组进行照射,利用克隆形成实验计算细胞存活比率(SF);(2)细胞给予总剂量为2Gy、4Gy、6Gy、8Gy的照射,并按照每日单次照射时间的不同分为A组(照射2分钟组)、B1组(照射10分钟组)、B2组(照射30分钟组).观察延长照射时间对肺鳞癌细胞株H520存活比率的影响.结果 伴随单次照射总时间的延长,实验细胞的存活比率逐渐提高,接受照射总剂量为8Gy的H520细胞株,A组细胞存活比率为1.9%;B1组和B2组存活比率分别为2.35%和3.42%.A组与B2组之间的差异具有统计学意义(P<0.05).结论 常规剂量分割模式下延长单次照射时间,显著降低了放射治疗对H520细胞的生物效应.%Objective The purpose of this study was to observe the radiobiological effects of lung squamous cancer cell line H520 irradiated over prolonged single fraction delivery time in the conventional dose fractionated mode. Methods (1)The H520 cell lines were cultured in vitro, and then irradiated by groups. Its survival fractions(SF)were calculated with standard clonogenic assays.( 2 )The total doses of 2 Gy,4 Gy,6 Gy,8 Gy were given to the cells,which were divided into groups by different single fraction delivery time:group A( group irradiated for 2 mins ),group Bl( group irradiated for 10 mins ),and group B2( group irradiated for 30 mins ),and observed the impact on the survival fractions of H520 cell line with prolonged fraction delivery time. Results The cell surviving fractions increased when the interfraction interval was longer. The values of SF 8 Gy were 1. 9% in group A,2.35% in group B1,and increased to 3. 42% in group B2 ,respectively. The difference between group A and group B2 was statistically significant(P<0.05 ). Conclusion The prolonged fraction delivery time would significantly decrease the

  9. Coastal Engineering, vol I, Introduction

    NARCIS (Netherlands)

    Massie, W.W.

    1976-01-01

    Overview, oceanography, Beaufort scale, short waves, wave speed, shoaling, Types of breakers, wave refraction and diffraction, wave statistics, application of wave statistics, wave data, optimum design, history of harbor development, approach channels, dredging equipment, dredging spoil disposal, br

  10. The Writing Workshop. Vol. 2.

    Science.gov (United States)

    Ziegler, Alan

    The second of two volumes, this book is primarily concerned with the teaching of creative writing at any grade level, although some ideas may not be applicable to teaching very young students. This volume focuses on how to generate writing assignments, and while it is designed for classroom teachers, it can also be used by individual writers.…

  11. Passages from India, Vol. 2.

    Science.gov (United States)

    Geils, Kenneth, Ed.

    This is compendium of readings designed for use in the secondary classroom to assist with the study of India. There are seventeen categories of readings: (1) introduction to the subcontinent; (2) description of society; (3) caste and its continuing impact; (4) leadership roles; (5) women in India; (6) role playing in society; (7) marriage; (8)…

  12. Vibration Theory, Vol. 1A

    DEFF Research Database (Denmark)

    Nielsen, Søren R. K.

    The present collection of solved problems has been published as a supplement to the textbook Svingningsteori. Bind 1. Lineær svingningsteori,Aalborg tekniske Universitetsforlag, 1991, whicj is used in the introductory course on linear vibration theory that is being given on th e8th semester at th...

  13. Goods Transport Modelling, Vol 1

    DEFF Research Database (Denmark)

    Petersen, Morten Steen (red.); Kristiansen, Jørgen

    The report is a study of data requirements and methodologies for goods transport. The study is intended to provide the basis for general discussion about the application of goods transport models in Denmark. The report provides an overview of different types of models and data availability....

  14. Highlights of Astronomy, Vol. 15

    Science.gov (United States)

    Corbett, Ian

    2010-11-01

    Preface; Part I. Gruber Cosmology Prize Lecture; Part II. Invited Discourses; Part III. Joint Discussions: 1. Dark matter in early-type galaxies Léon V. E. Koopmans and Tommaso Treu; 2. Diffuse light in galaxy clusters Magda Arnaboldi and Ortwin Gerhard; 3. Neutron stars - timing in extreme environments Tomaso Belloni, Mariano Méndez and Chengmin Zhang; 4. Progress in understanding the physics of Ap and related stars Margarida Cunha; 5. Modelling the Milky Way in the age of Gaia Annie C. Robin; 6. Time and astronomy Pascale Defraigne; 7. Astrophysical outflows and associated accretion phenomena Elisabete M. de Gouveia Dal Pino and Alex C. Raga; 8. Hot interstellar matter in elliptical galaxies Dong-Woo Kim and Silvia Pellegrini; 9. Are the fundamental constants varying with time? Paolo Molaro and Elisabeth Vangioni; 10. 3D views on cool stellar atmospheres - theory meets observation K. N. Nagendra, P. Bonifacio and H. G. Ludwig; 11. New advances in helio- and astero-seismology; 12. The first galaxies - theoretical predictions and observational clues; 13. Eta Carinae in the context of the most massive stars Theodore R. Gull and Augusto Damineli; 14. The ISM of galaxies in the far-infrared and sub-millimetre; 15. Magnetic fields in diffuse media Elisabete M. de Gouveia Dal Pino and Alex Lazarian; 16. IHY global campaign - whole heliosphere interval; Part IV. Special Sessions: SpS 1. IR and sub-mm spectroscopy - a new tool for studying stellar evolution Glenn Wahlgren, Hans Käufl and Florian Kerber; SpS 2. The international year of astronomy Pedro Russo, Catherine Cesarsky and Lars Lindberg Christensen; SpS 3. Astronomy in Antarctica in 2009 Michael G. Burton; SpS 4. Astronomy education between past and future J. P. De Greve; SpS 5. Accelerating the rate of astronomical discovery Ray P. Norris; SpS 6. Planetary systems as potential sites for life Régis Courtin, Alan Boss and Michel Mayor; SpS 7. Young stars, brown dwarfs, and protoplanetary disks Jane Gregorio-Hetem and Silvia Alencar; SpS 8. The galactic plane N. A. Walton, A. Damineli, M. G. Hoare, J. E. Drew, Roberto D. D. Costa and Walter J. Maciel; SpS 9. Marking the 400th anniversary of Kepler's 'astronomia nova' T. J. Mahoney; SpS 10. Next generation large astronomical facilities Gerard F. Gilmore and Richard T. Schilizzi; Author index.

  15. IBIS Vol. 3.0

    Energy Technology Data Exchange (ETDEWEB)

    2004-07-12

    IBIS (massively parallelized version 2) is a comprehensive model of terrestrial biospheric processes, and includes land surface physics, canopy physiology, plant phenology, vegetation dynamics and competition, and carbon cycling. The land surface module simulates the energy, water, carbon and momentum balance of soil/vegetation/atmospheric system on a short time step consistent with general circulation models (20-60 minutes). The module includes two vegetation layers (trees, and grasses and shrubs) and six soil layers to simulate soil temperature, soil water, and soil ice content over a total depth of 4 m. Physiologically-based formulations of C3 and C4 photosynthesis (Farquhar. et al., 1980), stomatal conductance (Collatz, et al., 1992; Collatz, et al., 1991) and respiration (Amthor, 1984) are used to simulate canopy gas exchange processes. Budburst and senescence depend on climatic factors following the empirical algorithm presented by Botta, et al. (2000). The annual carbon balance allows the vegetation dynamics submodel to predict the maximum leaf area index and biomass for 12 plant functional types, which compete for light and water. IBIS represents vegetation dynamics using very simple competition rules. The relative abundance of the 12 platn functional types in each grid cell changes in time according to their ability to photosynthesize and use water, IBIS simulates carbon cycling through vegetation, litter and soil organic matter. The soil biogeochemistry model of Verbene, et al. (1990). The total below-ground carbon in the first meter of soil is divided into pools characterized by their residence time: from a few hours for the microbal biomass to more than 1000 years for stabilized organic matter. Decomposition rates of litter and soil carbon depend on soil temperature and soil moisture.

  16. Flying Qualities (Qualites de Vol)

    Science.gov (United States)

    1991-02-01

    fighter bombers and the Mercure transport plane, to the differenk supers -nic Mirages fighters and to, the vario.us Falcon bussiness jet family members...his numbers for ever. He only intended to present a basis of discussion. But everybody grabbed the numbers and called them practically "the law for...flight path behaviour, suff;c,3J to gain/phase deficiencies in FBW *.;ontrcl law * quat~tify in general terms the response desigrn, which ca"l be

  17. RBE, reference RBE and clinical RBE: applications of these concepts in hadron therapy.

    Science.gov (United States)

    Wambersie, A

    1999-06-01

    Introduction of heavy particles (hadrons) into radiation therapy aims at improving the physical selectivity of the irradiation (e.g. proton beams), or the radiobiological differential effect (e.g. fast neutrons), or both (e.g. heavy-ion beams). Each of these new therapy modalities requires several types of information before prescribing safely the doses to patients, as well as for recording and reporting the treatments: (i) absorbed dose measured in a homogeneous phantom in reference conditions; (ii) dose distribution computed at the level of the target volume(s) and the normal tissues at risk; (iii) radiation quality from which a RBE evaluation could be predicted and (iv) RBE measured on biological systems or derived from clinical observation. In hadron therapy, the RBE of the different beams raises specific problems. For fast neutrons, the RBE varies within wide limits (about 2 to 5) depending on the neutron energy spectrum, dose, and biological system. For protons, the RBE values range between smaller limits (about 1.0 to 1.2). A clinical benefit can thus not be expected from RBE differences. However, the proton RBE problem cannot be ignored since dose differences of about 5% can be detected clinically in some cases. The situation is most complex with heavy ions since RBE variations are at least as large as for fast neutrons, as a function of particle type and energy, dose and biological system. In addition, RBE varies with depth. Radiation quality thus has to be taken into account when prescribing and reporting a treatment. This can be done in different ways: (a) description of the method of beam production; (b) computed LET spectra and/or measured microdosimetric spectra at the points clinically relevant; (c) RBE determination. The most relevant RBE data are those obtained for late tolerance of normal tissues at 2 Gy per fraction ("reference RBE"). The "clinical RBE" selected by the radiation oncologist when prescribing the treatment will be close to the

  18. Research trends in radiobiology since 40 years. a new approach: the enzymatic repair function of DNA, internal factor in evolution of biological systems under irradiation; Etude des tendances des recherches en radiologie depuis 40 ans. Une nouvelle voie de recherche: la fonction de reparation enzymatique de l'ADN, facteur interne d'evolution des systemes biologiques sous rayonnement

    Energy Technology Data Exchange (ETDEWEB)

    Mouton, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    In the first part of the report, the author attempts to draw an historical scheme of successive research working hypotheses in radiobiology since 1924. Less than a generation ago the effect of radiation exposure were viewed as being direct, immediate, irreparable and unmodifiable. Now it is generally accepted that radiation lesion can also be indirect, delayed, reparable and often modified with appropriate chemical or biochemical treatment. It was however in 1962-1964 that came the decisive breakthrough in radiobiology with the discovery that the cell possesses a natural active self-defense mechanism against whatever stress would affect the integrity of the genetic message contained in the DNA structure itself. The existence of what could be considered as a fourth DNA function i.e. self-repair by enzymatic action under genetic control-brings at least to radiobiology the missing molecular biology basis it needed to get out of its 'phenomenological night' after abandon of the generalization of Lea's theory through lack of experimental evidence. In the second part, which is a prospective one, the author tries to set an enlarged synthesis considering the possible role of DNA repair system not only in cell survival - in presence or absence of dose modifiers or mutagens - but also in the artificial and natural evolution of biological system exposed to sub-lethal doses of radiation. Most recent data from the literature fit well with what must be still considered as a general working hypothesis. Studies dealing with phenotypic and genotypic characters linked with the acquisition of gamma and UV radiation resistance in 'Escherichia coli K12' has been started by the author, in collaboration with O. Tremeau, in order to bring a new experimental contribution in this respect. (author) [French] Dans la premiere partie, l'auteur tente de retracer l'historique des hypotheses successives qui ont jalonne les avances de la radiobiologie depuis 1924

  19. Types of Treatment: Clinical Trials

    Science.gov (United States)

    ... Disease Information Treatment Types of Treatment Clinical Trials Clinical Trials Clinical Trials SHARE: Print Glossary Taking part in a clinical ... for cancer are based on previous clinical trials. Clinical Trial Service: LLS provides personalized clinical trial navigation when ...

  20. The change of cerebral blood flow after heart transplantation in congestive heart failure: a voxel-based and automatic VOl analysis of Tc-99m ECD SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Hong, I. K.; Kim, J. J.; Lee, C. H.; Lim, K. C.; Moon, D. H.; Rhu, J. S.; Kim, J. S. [Asan Medical Center, Seoul (Korea, Republic of)

    2007-07-01

    To investigate the change of global and regional cerebral blood flow after heart transplantation (HT) in congestive heart failure (CHF) patients. Twenty-one patients with CHF who underwent HT (45{+-}12 yrs, M/F=19/2) and 10 healthy volunteers (39{+-}13 yrs, M/F = 7/3) were prospectively included. All patients underwent echocardiography and radionuclide angiography including brain and aorta with brain SPECT which was performed after iv bolus injection of Tc-99m ECD (740MBq) before (175{+-}253 days) and after (129{+-}82 days) HT. Patients were divided into two groups according to the interval between HT and postoperative SPECT [early follow-up (f/u): <6 mo, n=14; late f/u: >6 mo, n=7]. Global CBF (gCBF) of bilateral hemispheres were calculated by Patlak graphical analysis. Absolute rCBF map was obtained from brain SPECT by Lassen's correction algorithm. Age-corrected voxel-based analysis using SPM2 and automatic VOl analysis were performed to assess the rCBF change. Cardiac ejection fraction of all patients improved after HT (20.8%{yields}64.0%). gCBF was reduced compared to normal before HT (35.7{+-}3.9 vs. 49.1{+-}3.0 ml/100g/min; p<0.001) and improved postoperatively (46.6{+-}5.4, p<0.001). The preoperative gCBFs of early and late f/u group were not different (34.6{+-}3.2 vs. 38.0{+-}4.4, p=0.149) but postoperative gCBF (43.9{+-}3.7) of late f/u group was higher than those (52.0{+-}4.0) of early f/u group (p<0.001). On voxel-based analysis, preoperative rCBF was reduced in entire brain but most severely in bilateral superior and inferior frontal cortex, supplementary motor area, precuneus and anterior cingulum, compared to normals (uncorrected p<0.001). After HT, rCBF of these areas improved more significantly in late f/u group than in early f/u group but still lower than normals. Global CBF was significantly reduced in CHF patients and improved after HT. rCBFs of the frontal cortex, precuneus and cingulum were most severely reduced and slowly improved after

  1. Efeito fitotóxico do óleo volátil de Cleome guianensis Aubl. sobre o crescimento inicial de Senna occidentalis L.

    Directory of Open Access Journals (Sweden)

    A.C.S.S. VENTURA

    2016-01-01

    Full Text Available RESUMO Aleloquímicos são substâncias liberadas por certas espécies vegetais no ambiente que influenciam a germinação e o desenvolvimento de outras plantas. O objetivo desse estudo foi avaliar o potencial fitotóxico de Cleome guianensis Aubl., bem como determinar o grau de estresse oxidativo causado em Senna occidentalis L. Para isso, o óleo das folhas de C. guianensis, nas concentrações 0,5 µg/mL, 1,0 µg/mL, 2,5 µg/mL e 5,0 µg/mL, em solução de 5 ml foi testado em bioensaios de germinação e de crescimento da raiz primária e do hipocótilo de S. occidentalis. Os indivíduos de S. occidentalis foram macerados, homogeneizados e submetidos a ensaios de quantificação da catalase, peroxidase, SOD e de peroxidação lipídica. Os resultados indicam que todas as concentrações do óleo volátil causaram um efeito negativo sobre a germinação e crescimento de S. occidentalis. Na concentração 5,0 µg/mL, houve 56% de inibição da germinação e 83% de inibição de crescimento do hipocótilo. Ainda, o óleo aumentou a atividade das enzimas induzidas pelo estresse oxidativo catalase, peroxidase e superóxido dismutase (SOD. Quanto à peroxidação lipídica, o óleo nas concentrações 1,0 µg/mL, 2,5 µg/mL e 5,0 µg/mL aumentou a produção de malondialdeído. Sendo assim, conclui-se que C. guianensis apresenta aleloquímicos que influenciam na germinação e no crescimento de S. occidentalis, além de aumentar a atividade das enzimas catalase, peroxidase, SOD e a produção de malondialdeído em S. occidentalis. Dessa forma, sugere-se a realização de estudos sobre o perfil químico do óleo a fim de descobrir as substâncias responsáveis por tais resultados e consolidar o potencial fitotóxico de C. guianensis.

  2. Proposal of a high dose rate brachytherapy model for in vitro radiobiology studies; Proposta de um modelo de braquiterapia de alta taxa de dose para estudos de radiobiologia in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Geraldo, Jony M.; Nogueira, Luciana B.; Andrade, Lidia M. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Trindade, Cassia [Hospital Luxemburgo, Belo Horizonte, MG (Brazil); Furtado, Clascidia A.; Ladeira, Luiz Orlando, E-mail: jony.marques@mariopenna.org.br [Centro de Desenvolvimento da Tecnologia Nuclear (CTDN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2016-07-01

    The aim of this research was to develop an easy and reproducible approach for experimental HDR brachytherapy allowing in vitro irradiation studies based on clinical parameters. An acrylic platform was designed to attach T25 tissue culture flasks and multi-well tissue culture plates as well as kept the catheters in a fixed position during irradiation. CT images were taken and the irradiation was planned for 550cGy dose applied on adherent tumor cells. Dosimetric measurements were done and all relevant uncertainties were taken into account in order to figure out the correct dose range received by the cells. Tumor cells were irradiated two times over an interval of 24h between irradiations. Proof of concepts of this approach was carried out by biological effects analysis using a radioresistant human epidermoid carcinoma A431 cell line. Cellular proliferation and cell cycle phase were assessed by Trypan blue exclusion assay and DNA content analysis by flow cytometry, respectively. This approach allowed uniform dose distribution around the arrangement in all types of tissue culture plastics evaluated. Corrections due to uncertainties were managed. Regarding in vitro assays there was a significant (p<0.05) decreasing of cellular proliferation rate in irradiated cells. Moreover, increased percentage of cells arrested in G2/M phase (32.3 ± 1.5%) were observed for treated group compared with untreated cells. (author)

  3. Future requirements. Clinical investigations

    DEFF Research Database (Denmark)

    Qvist, V.

    2002-01-01

    Biocompatability, Cariology, Clinical trials, Dental materials, Helath services research, Human, Pedodontics......Biocompatability, Cariology, Clinical trials, Dental materials, Helath services research, Human, Pedodontics...

  4. Volatile profile of heated soybean oil treated with quercetin and chlorogenic acid Perfil de compostos voláteis do óleo de soja aquecido e tratado com quercetina e ácido clorogênico

    Directory of Open Access Journals (Sweden)

    Adriana Leão de Miranda

    2008-12-01

    Full Text Available Changes in the profile of volatile compounds after the heating of refined soybean oil without adding antioxidants, and treated with quercetin and chlorogenic acid (5-CQA were investigated by GC/FID, GC/MS, and GC/SNIFFING. The heating temperature of the oil sample was 20 °C for the first minute, and then it was increased up to 160 °C at the rate of 10 °C min-1. The final temperature was kept for 10 minutes. 19 volatiles were identified in the heated samples without antioxidants. Medium-chain carbonyls predominated in the volatile fraction, mainly 2-heptenal, 2,4-heptadienal and 2,4-decadienal. Around 11 to 15 volatile compounds were detected in the heated samples treated with 5-CQA and quercetin, respectively. 5-CQA was not very efficient in delaying the formation of oxidative volatile compounds. The samples quercetin presented lower proportion of carbonyls with C6-C9.. The GC peak area data were used as an approach to estimate the relative content of each volatile compound and indicate that the samples treated with quercetin (p As alterações no perfil de compostos voláteis, após o aquecimento de óleo de soja refinado sem a adição de antioxidantes e tratado previamente com quercetina e ácido clorogênico (5-ACQ, foram investigadas através da CG/DIC, CG/EM e CG/SNIFFING. A temperatura de aquecimento do óleo foi de 20 °C no primeiro minuto e aumentada até 160 °C à taxa de 10 °C min-1. A temperatura final foi mantida por 10 minutos. Um total de 19 compostos voláteis foi identificado nas amostras aquecidas sem a adição de antioxidantes. As carbonilas de cadeia média predominaram na fração volátil. Cerca de 15 e 11 compostos voláteis foram detectados no óleo aquecido com adição prévia de quercetina e 5-ACQ, respectivamente. As amostras tratadas com quercetina mostraram uma menor proporção de carbonilas com esqueletos de carbono C6-C9. A composição estimada de compostos voláteis mostrou que amostras tratadas com

  5. Clinical toxicology: clinical science to public health.

    Science.gov (United States)

    Bateman, D N

    2005-11-01

    1. The aims of the present paper are to: (i) review progress in clinical toxicology over the past 40 years and to place it in the context of modern health care by describing its development; and (ii) illustrate the use of clinical toxicology data from Scotland, in particular, as a tool for informing clinical care and public health policy with respect to drugs. 2. A historical literature review was conducted with amalgamation and comparison of a series of published and unpublished clinical toxicology datasets from NPIS Edinburgh and other sources. 3. Clinical databases within poisons treatment centres offer an important method of collecting data on the clinical effects of drugs in overdose. These data can be used to increase knowledge on drug toxicity mechanisms that inform licensing decisions, contribute to evidence-based care and clinical management. Combination of this material with national morbidity datasets provides another valuable approach that can inform public health prevention strategies. 4. In conclusion, clinical toxicology datasets offer clinical pharmacologists a new study area. Clinical toxicology treatment units and poisons information services offer an important health resource.

  6. Uses of clinical algorithms.

    Science.gov (United States)

    Margolis, C Z

    1983-02-04

    The clinical algorithm (flow chart) is a text format that is specially suited for representing a sequence of clinical decisions, for teaching clinical decision making, and for guiding patient care. A representative clinical algorithm is described in detail; five steps for writing an algorithm and seven steps for writing a set of algorithms are outlined. Five clinical education and patient care uses of algorithms are then discussed, including a map for teaching clinical decision making and protocol charts for guiding step-by-step care of specific problems. Clinical algorithms are compared as to their clinical usefulness with decision analysis. Three objections to clinical algorithms are answered, including the one that they restrict thinking. It is concluded that methods should be sought for writing clinical algorithms that represent expert consensus. A clinical algorithm could then be written for any area of medical decision making that can be standardized. Medical practice could then be taught more effectively, monitored accurately, and understood better.

  7. Pre-clinical and Clinical Evaluation of High Resolution, Mobile Gamma Camera and Positron Imaging Devices

    Science.gov (United States)

    2010-10-01

    S. Majewski, R. Wojcik, A.G. Weisenberger, B. Kross, V. Popov, “Correction for the Effects of Accidental Coincidences , Compton Scatter and Object... Coincidence Imaging with a Gamma Camera ”, IEEE Transactions on Nuclear Science, Vol. 48, No. 1, Feb. 2001, Pg. 98-105. [14] R.S. Miyaoka, S.K...Coleman, “Attenuation Effects in Gamma Camera Coincidence Imaging”, IEEE Transactions on Nuclear Science, Vol. 45, No. 6, Dec. 1998, Pg. 3115-3121

  8. An Improved Airborne Wind Measurement Technique for the NAE (National Aeronautical Establishment) Twin Otter (Nouvelle Methode De Mesure Du Vent En Vol a Bord Du Twin Otter De L’ena)

    Science.gov (United States)

    1989-11-01

    filtre de Kalman , laquelle rdsout ce probl~me et permet de mesurer le vent avec une exactitude sup6rieure A celle des anciennes m6thodes. D’apr6s les...premiers r6sultats bases sur ’application d’un filtre de Kalman aux donn6es des essaip en vol du Twin Otter, il semble qu’il soit possible d’obtenir...actually degrading wind computation accuracy compared with older techniques. A new wind measurement technique, based on a Kalman filter integrated

  9. Respuesta de Anopheles albimanus a compuestos volátiles de casas del sur de Chiapas, México Behavioral response of Anopheles albimanus to volatile compounds collected inside houses from the south of Chiapas, Mexico

    Directory of Open Access Journals (Sweden)

    Silvany Mayoly Ríos-Delgado

    2008-10-01

    Full Text Available OBJETIVO: Determinar el efecto de los compuestos volátiles en las casas sobre la respuesta conductual del vector del paludismo Anopheles albimanus. MATERIAL Y MÉTODOS: El estudio se realizó en enero de 2006 en el ejido Nueva Independencia, municipio de Suchiate, Chiapas. Se colectaron compuestos volátiles dentro de casas y los extractos se probaron sobre hembras sin alimentar en un olfatómetro en "Y". Los extractos se analizaron mediante cromatografía de gases-espectrometría de masas (CG-EM. RESULTADOS: Se obtuvieron 28 extractos, 12 presentaron respuesta de atracción y dos de repelencia. Los análisis por CG-EM indicaron variación en la presencia de compuestos volátiles y no se vincularon con compuestos específicos indicativos de algún efecto. CONCLUSIONES: Los volátiles en casas presentaron efecto de atracción y repelencia para An. albimanus. No se reconoció un patrón definido en cuanto a la presencia de compuestos químicos característicos y la respuesta obtenida.OBJECTIVE: To determine effects of volatile compounds in homes on the behavioral response of Anopheles albimanus. MATERIAL AND METHODS: The study was conducted in January 2006, in the village of Nueva Independencia village, Suchiate, Chiapas. Volatile compounds were collected inside homes and the extracts were tested on unfed females in a Y-olfactometer. Extracts were analyzed in a gas chromatography-mass spectrometry system (GC-MS. RESULTS: Twenty eight extracts were obtained, twelve presented attraction and two repellency responses. GC-MS analyses of the extracts indicated variation in the volatile compound present in the extracts, but could not associated specific compounds with any particular effect. CONCLUSIONS: Within homes, volatiles presented attraction and repellency responses to An. albimanus. A definate pattern concerning the presence of a characteristic chemical compound and the observed response was not found.

  10. Aplicación del método de bakhuis-rooseboom para el cálculo de volúmenes específicos parciales en sistemas ternarios

    OpenAIRE

    Rodriguez, Sylvia; Vargas, Ricardo; Pinzón, Jorge; Barbosa, Helber; Martinez, Fleming

    2008-01-01

    Tomando como base el método de los interceptos y las pendientes de Bakhuis-Rooseboom, en este trabajo se desarrolló una aplicación en la determinación de los volúmenes específicos parciales de componentes en mezclas ternarias, lo cual resulta de utilidad práctica en el diseño de medicamentos líquidos homogéneos ya que permite estimar las contribuciones volumétricas de cada uno de los componentes en el momento de la preformulación de estos sistemas de entrega de fármacos

  11. Estudo comparativo dos óleos voláteis de algumas espécies de Piperaceae Comparative study of the essential oils of some species of Piperaceae

    Directory of Open Access Journals (Sweden)

    J.M.O. Mesquita

    2005-03-01

    Full Text Available O presente trabalho teve por objetivo a análise comparativa dos óleos voláteis de espécies da família Piperaceae. As espécies estudadas foram as seguintes: Piper aduncum, P. amalago, P. arboreum, P. cernuum, P. hispidum, P. regnelii, P. submarginalum, P. vicosanum e Pothomorphe umbellata. A análise dos óleos voláteis foi efetuada pela combinação de técnicas de Cromatografia de Fase Gasosa (CG e de Cromatografia de Fase Gasosa acoplada a Espectrometria de Massa (CG/EM. A porcentagem de identificação dos constituintes nas análises dos óleos voláteis de Piper aduncum, P. amalago, P. vicosanum, P. submarginalum e Pothomorphe umbellata, atingiu valores superiores a 80%. Houve predominância de compostos de natureza sesquiterpênica nas composições químicas das espécies analisadas, com exceção de P. hispidum, P. submarginalum e P. vicosanum onde a predominância na composição foi de monoterpenos. Pelos dados apresentados observou-se que, dentre os compostos majoritários, os mais freqüentes, nas 9 espécies estudadas, foram beta-pineno (9/9 e espatulenol (9/9, seguidos por E-cariofileno (8/9, óxido de cariofileno (8/9, germacreno D (7/9, alfa-pineno (7/9 e limoneno (6/9. Pela primeira vez se relata a composição dos óleos voláteis de P. submarginalum e P vicosanum.Essential oils from various vegetal species of the Piperaceae family were analysed by Capillary Gas Chromatography (GC and Gas Chromatography/Mass Spectrometry (GC/MS. The investigated species were: Piper aduncum, P. amalago, P. arboreum, P. cernuum, P. hispidum, P. regnelii, P. submarginalum, P. vicosanum and Pothomorphe umbellata. Over 80% of the essential oils compounds were identified by the qualitative and quantitative analysis. The analysed species showed the predominance of sesquiterpenoids, except for P. hispidum, P. submarginalum and P. vicosanum in which the predominant compounds were monoterpenoids. For the 9 studied species, the major compounds found

  12. Sensores de fibra óptica para la detección de compuestos orgánicos volátiles basados en materiales silíceos porosos.Efectos de las propiedades texturales y superficiales

    OpenAIRE

    Vaquero Rivero, Alejandro

    2010-01-01

    El presente trabajo fin de carrera aborda el desarrollo de sensores de fibra óptica para la detección de compuestos orgánicos volátiles. El objetivo general es preparar sensores de fibra óptica que empleen como elemento sensor xerogeles silíceos con diferente textura porosa y polaridad. Se compara la respuesta de los elementos sensores frente a diclorometano, acetona, metanol y ciclohexano. Los xerogeles se caracterizaron mediante espectroscopía infrarroja y adsorción de N...

  13. Cytotoxic evaluation of essential oil from Zanthoxylum rhoifolium Lam. leaves Avaliação citotóxica do óleo volátil extraído das folhas do Zanthoxylum rhoifolium Lam.

    Directory of Open Access Journals (Sweden)

    Saulo Luis da Silva

    2007-06-01

    Full Text Available Zanthoxylum rhoifolium Lam is a plant popularly used as antimicrobial, for malaria and inflammatory treatment. The essential oil of Z. rhoifolium was extracted and its cytotoxic effects against HeLa (human cervical carcinoma, A-549 (human lung carcinoma, HT-29 (human colon adenocarcinoma, Vero (monkey kidney cell lines and mice macrophages were evaluated. Some of the terpenes of its essential oil (ß-caryophyllene, alpha-humulene, alpha -pinene, myrcene and linalool were also tested to verify their possible influence in the oil cytotoxic activity. The results obtained permitted to confirm that the essential oil is cytotoxic against tumoral cells (CD50 = 82.3, 90.7 and 113.6 µg/ml for A-549, HeLa e HT-29 cell lines, respectively, while it did not show cytotoxicity against non-tumoral cells (Vero and mice macrophages. Thus, the essential oil from Z. rhoifolium leaves seems to present a possible therapeuthic role due to its selective cytotoxic activity against tumoral cell lines.O Zanthoxylum rhoifolium Lam. é uma planta popularmente utilizada como antimicrobianos, no tratamento da malária e de inflamações. O óleo volátil do Z. rhoifolium foi extraído e posteriormente foi avaliada a sua citotoxicidade contra células HeLa (carcinoma cervical humano, A-549 (carcinoma de pulmão humano, HT-29 (adenocarcinoma de cólon humano, Vero (rim de macaco e macrófagos de camundongos. Alguns terpenos constituintes do óleo volátil (beta-cariofileno, alfa -humuleno, alfa -pineno, mirceno e linalool também foram testados para verificar as possíveis influências sobre a citotoxicidade do óleo. Os resultados obtidos permitiram verificar que o óleo volátil é citotóxico contra células as tumorais (CD50 = 82.3, 90.7 e 113.6 µg/ml para A-549, HeLa e HT-29 cell lines, respectivamente, mas não apresenta citotoxicidade contra as células não tumorais (Vero e macrófagos de camundongos. Desta forma o óleo volátil das folhas do Z. rhoifolium demonstra

  14. Degradação de compostos orgânicos voláteis em fase gasosa através da fotocatálise com luz UV, TiO2 e TiO2/Pt

    OpenAIRE

    Milena Ponczek

    2014-01-01

    Compostos orgânicos voláteis, ou COV, são uma importante classe de poluentes do ar comumente encontrados na atmosfera ao nível do solo, nos centros urbanos e industriais. O tratamento de COV provenientes de fontes industriais através da fotocatálise heterogênea é uma técnica eficiente para a degradação de baixas concentrações de uma grande gama de compostos orgânicos diferentes (hidrocarbonetos, aromáticos, alcóois, cetonas, etc) operando em condições ambientes. Um dos problemas que ainda imp...

  15. Clinical Trials in Vision Research

    Science.gov (United States)

    ... Eye Health Information > Clinical Trials in Vision Research Clinical Trials in Vision Research Clinical studies depend on people ... vision research in the United States. Basics of Clinical Trials What is a clinical trial? Clinical trials are ...

  16. Reply to Comment on ‘Implications on clinical scenario of gold nanoparticle radiosensitization in regards to photon energy, nanoparticle size, concentration and location’

    Science.gov (United States)

    Pignol, Jean-Philippe; Lechtman, Eli

    2012-01-01

    In a comment on a recent paper by Lechtman et al (2011 Phys. Med. Biol. 56 4631-47), McMahon critiques one of Lechtman's conclusion that gold nanoparticle radiosensitization may not be applicable to megavoltage radiotherapy. He refers to recently published experimental studies showing radiosensitization with 6 MV x-rays and low gold concentrations. However those published studies show conflicting results, presenting survival curves with a small cell death increased with gold and some with no difference. In regards to gold nanoparticle radiosensitization physical, chemical, pharmacological and biological constraints all interplay. There are plenty of experimental and theoretical data to confirm the strong dependence to the primary photon energy and gold concentration. The manuscript of Lechtman added the dependence to microscopic localization, analysing the spatial distribution and the quality of secondary electrons, as a major player in the feasibility of the technique. We agree that radiobiological dose modification factor should be considered, but it is unlikely that accounting for a maximum RBE of 2 can compensate for the drastic decrease of photoelectric events shifting from kV to MV. Lechtman calculated that to achieve similar radiosensitization for low energy beams and intra-cellular gold concentration of 0.5%, concentrations 300 times higher are required for 6 MV beams. To date it seems unlikely that concentration higher than 1% could be achieved such that it is unlikely that megavoltage would yield a measurable clinical effect.

  17. History of clinical pharmacy and clinical pharmacology.

    Science.gov (United States)

    Miller, R R

    1981-04-01

    The purpose of the Symposium on Clinical Pharmacy and Clinical Pharmacology is to describe the present and future functional roles of clinical pharmacists and clinical pharmacologists in drug research, professional education, and patient care. Clinical pharmacy is a relatively new professional discipline, being only about 15 years old. This new breed of pharmacists is patient rather than drug product oriented. The discipline arose out of dissatisfaction with old practice norms and the pressing need for a health professional with a comprehensive knowledge of the therapeutic use of drugs. The clinical pharmacy movement began at the University of Michigan in the early 1960s, but much of the pioneering work was done by David Burkholder, Paul Parker, and Charles Walton at the University of Kentucky in the latter part of the 1960s. Clinical pharmacology is a professional discipline that combines basic pharmacology and clinical medicine. Its development began in the early 1950s, primarily as a result of the efforts of Harry Gold. It has had a slower growth than clinical pharmacy but it has made many important contributions to our knowledge of human pharmacology and the rational use of drugs.

  18. Development of clinical scientists.

    Science.gov (United States)

    Smith, R V

    1987-01-01

    The education and training of clinical scientists has served society in several ways. For academic pharmacy, the emergence of clinical science has provided research and scholarship opportunities for clinical faculty development. Clinical scientists have also begun to play important roles in industrial drug research and development. For all faculty and students, clinical science research reinforces a "research mindset" that will become increasingly important as our society moves from a production/extraction to an information-based economy. Pharmacy will best evolve by increasing its commitment to clinical science research. In the process, academic pharmacy must continue to improve and support excellent education and training programs for clinical scientists.

  19. Efeitos cardiovascular e metabólico da reposição volêmica com hidroxietilamido 130/0,4 em felinos domésticos com hipovolemia induzida Cardiovascular and metabolic effects of volemic expansion with hydroxyethyl starch 130/0,4 in domestic cats with induced hypovolemia

    Directory of Open Access Journals (Sweden)

    André Vasconcelos Soares

    2009-04-01

    Full Text Available O objetivo deste estudo foi comparar os efeitos da expansão volêmica produzida pelo hidroxietilamido 130/0,4 (HES 130/0,4 ou pelo sangue em gatas com hipovolemia induzida. Foram utilizadas 12 gatas adultas, sem raça definida (SRD, com peso médio de 2,85±0,28kg e hígidas. Os animais foram induzidos à anestesia geral com isofluorano a 5V%, intubados e conectados a um sistema sem reinalação de gases. Após a instrumentação, os animais foram mantidos sob anestesia com isoflurano em 1,3V% e mantidos em ventilação mecânica, ciclada a pressão. Em seguida, foi induzida a hipovolemia por meio da retirada de 30ml kg-1 de sangue da artéria femoral. Após 60 minutos da estabilização do paciente, os tratamentos foram iniciados. No grupo hidroxietilamido (GH, n=06, os animais receberam, como reposição volêmica, o hidroxietilamido 130/0,4 no mesmo volume de sangue retirado e, no grupo sangue (GS, n=06, os animais receberam o próprio sangue retirado, sendo considerado grupo controle. A pressão arterial sistólica, a diastólica e a média e a pressão venosa central aumentaram após a reposição volêmica em ambos os grupos. Observou-se, para o GH, aumento da PaCO2 no T15, no T30 e no T60. Houve redução do pH no T30 e no T45 e de íons Na+ no T90 para GH. A restauração das pressões arteriais com a administração de HES 130/0,4 foi similar ao grupo controle. A reposição volêmica com HES 130/0,4 produz aumento acentuado da PVC; e o uso do HES 130/0,4 em gatas submetidas à hipovolemia não produziu alterações clinicamente significativas no equilíbrio ácido-básico.The aim of this study was to compare the volemic expansion effects produced by hydroxyethyl starch 130/0.4 (HES 130/0.4 or blood, in female cats with induced hypovolemia. Twelve healthy adult female cats, crossbreed and weighing an average of 2.85±0.28kg were used. They were induced into general anesthesia with isofluorane at 5V%, intubated and connected to a non

  20. Clinical approach to clinical herbal toxicity.

    Science.gov (United States)

    Tovar, Richard T

    2009-02-01

    This article is a review of the history and current status of herbs in the United States. The clinical effects of herbs and herbal medicine will be reviewed with respect to side effects and clinical toxicity. Treatment of herbal toxicity will be described where indicated.

  1. Galeno, Sobre la utilidad de las partes del cuerpo humano, vol. I. Estudio introductorio, bibliografía, traducción, notas e índices de Manuel Cerezo Magán

    Directory of Open Access Journals (Sweden)

    Carlos Martins de Jesus

    2014-12-01

    Full Text Available Galeno, Sobre la utilidad de las partes del cuerpo humano, vol. I. Estudio introductorio, bibliografía, traducción, notas e índices de Manuel Cerezo Magán, Madrid, Ediciones Clásicas, 2009, ISBN: 84‑7882‑689‑0; Galeno, Sobre la utilidad de las partes del cuerpo humano, vol. II, Estudio introductorio, bibliografía, traducción, notas e índices de Manuel Cerezo Magán, Madrid, Ediciones Clásicas, 2009, ISBN: 84‑7882‑689‑0; Galeno, Sobre la diferencia de los pulsos. Estudio introductorio, traducción, notas e índices de Luis Miguel Pino Campos, Madrid, Ediciones Clásicas, 2010, ISBN: 84‑7882‑680‑7; Galeno, Sobre los tipos. Sobre los días críticos. Traducción, introducción y notas de Mª Carmen García Sola, Madrid, Ediciones Clásicas, 2010, ISBN: 978‑84‑7882‑678‑0; Galeno, Comentario al Pronóstico de Hipócrates. Traducción, introducción y notas de Santiago Rubio Ferraz, Madrid, Ediciones Clásicas, 2010, ISBN: 84‑7882‑679‑3.http://dx.doi.org/10.14195/2183-1718_66_26

  2. Reply to `Extended Rejoinder to "Extended Comment on "One-Range Addition Theorems for Coulomb Interaction Potential and Its Derivatives" by I. I. Guseinov (Chem. Phys. Vol. 309 (2005), pp. 209 - 211)", arXiv:0706.0975v2"

    CERN Document Server

    Weniger, Ernst Joachim

    2007-01-01

    In the years from 2001 to 2006, Guseinov and his coworkers published 40 articles on the derivation and application of one-range addition theorems. In E. J. Weniger, Extended Comment on ``One-Range Addition Theorems for Coulomb Interaction Potential and Its Derivatives'' by I. I. Guseinov (Chem. Phys. Vol. 309 (2005), pp. 209 - 213), arXiv:0704.1088v2 [math-ph], it was argued that Guseinov's treatment of one-range addition theorems is at best questionable and in some cases fundamentally flawed. In I. I. Guseinov, Extended Rejoinder to "Extended Comment on "One-Range Addition Theorems for Coulomb Interaction Potential and Its Derivatives'' by I. I. Guseinov (Chem. Phys. and Vol. 309 (2005)'', pp. 209-213), arXiv:0706.0975v2 [physics.chem-ph], these claims were disputed. To clarify the situation, the most serious mathematical flaws in Guseinov's treatment of one-range addition theorems are discussed in more depth.

  3. Study of Nouns on the Chu’s Bamboo Slips of Warring States from Shanghai Museum(Vol IX)%《上博简(九)》名词研究

    Institute of Scientific and Technical Information of China (English)

    邱晨

    2014-01-01

    By making an exhaustive study on the nouns of The Chu’s Bamboo Slips of Warring States from Shanghai Museum (Vol IX), all the nouns are classified into normal nouns, proper nouns, nouns for time, nouns of orientation. Meanwhile, an intensive study of the nouns are conducted from grammatical function, multifunction, and flexible application. In the Chu’s Bamboo Slips of Warring States from Shanghai Museum (Vol IX), the proportion of the normal nouns is the most;the monosyllable nouns are more than polysyllabic nouns;few flexible use of the nouns, most of which is changing nouns into verbs.%对《上博简(九)》中的名词进行了穷进性的整理与研究,将全简的名词分为普通名词、专有名词、时间名词、方位名词四类。并从语法功能、兼类、活用等方面对简中的名词进行了更深入的探讨。发现《上博简(九)》中的名词中普通名词的比重最大;单音节名词比重大于多音节名词;名词的活用现象还比较少且多活用为动词。

  4. Estudio mediante tres técnicas del módulo elástico de un material compuesto de Al(6061 con un alto contenido (40%vol de SiC

    Directory of Open Access Journals (Sweden)

    Fernández, R.

    2001-04-01

    Full Text Available The purpose of this investigation is to study the elastic behavior of a discontinuously reinforced composite material, Al(6061-40vol%SiC, by using three different procedures: Extensometry in uniaxial testing, pendulum elasticimeter, and propagation of acoustic signals in the material. The high ceramic content of this material provides it with a high stiffness without a significant increase in density. Because of this, the material is suitable as structural component in the automotive and aerospace industry.

    El objetivo de esta investigación es estudiar el comportamiento elástico de un material compuesto con refuerzo discontinuo, Al(6061-40vol%SiC, mediante tres técnicas diferentes: extensometría para ensayos uniaxiales convencionales, elasticímetro pendular y mediante medidas de la velocidad de propagación de señales acústicas en el material. El alto contenido de la fase cerámica en este material le confiere elevada rigidez sin que su densidad aumente significativamente por lo que lo hacen adecuado como material estructural en diversas aplicaciones en el sector del transporte (automoción, aerospacial.

  5. Clinical grades: upward bound.

    Science.gov (United States)

    Walsh, Catherine M; Seldomridge, Lisa A

    2005-04-01

    This study examined the relationship of grades earned in paired theory and clinical courses. Data collected during academic years 1997 to 2002 confirmed that grade inflation exists in clinical nursing courses. Problems involved in awarding grades for clinical performance are discussed (e.g., standards of clinical performance, methods used in evaluation of clinical performance, the impossibility of faculty omnipresence, the influence of student effort in grading, the effect of recency, the challenges of keeping good anecdotal records). Solutions to grading problems are proposed, including dividing up performance into agreed-on elements, measurement of these elements on a grading scale that allows for more differentiation of quality in evaluating clinical performance, assigning grades from the beginning of a clinical course, emphasizing all three domains of clinical practice, and evaluating student performance in both laboratory and, clinical settings.

  6. Dual-energy X-ray absorptiometry and forced expiratory volumes in sedentary and trained children. [Absorciometria dual de rayos x y volúmenes espirométricos forzados en niños sedentarios y entrenados].

    Directory of Open Access Journals (Sweden)

    Álvaro Fernández-Luna

    2015-10-01

    Full Text Available Information regarding the influence of physical activity and fat mass in the human trunk on respiratory health is scarce. The aim of this study was to evaluate the influence of body composition and physical activity in forced expiratory volumes in children. The sample comprised 87 children between 8 and 13 years of age (9.62 ± 1.25, at Tanner stages I-III, participated in this study. Sixty played sports (trained children, TC and 27 were assigned to the sedentary children control group (SC. Body composition (DXA, anthropometric variables (weight and height, and forced expiratory volumes (FEV1 and FVC were determined in all subjects. Results showed that higher FEV1 and FVC values were found in the SC group compared to the TC group. Multiple regression analysis showed that physical activity, total fat mass, and android fat mass, had the highest predictive value for FVE1 as did height for the FVC. In SC group there was a positive association between FEV1/FVC ratio and Body Mass Index and trunk fat mass. We did not find any associations between forced respiratory volumes and the whole body and trunk region fat mass in trained and sedentary children. Resumen La información sobre los diferentes efectos de la actividad física y la masa grasa del tronco en la salud respiratoria es escasa. El objetivo fue evaluar la influencia de las variables de composición corporal y la práctica de actividad física en los volúmenes espirométricos forzados en edad infantil. 87 niños entre los 8 y 13 años (9,62 ± 1,25 (Tanner I-III participaron en el estudio. 60 practicaban diferentes deportes (niños entrenados, TC y 27 niños sedentarios fueron asignados al grupo control (SC. Se llevó a cabo la evaluación en todos los participantes de la composición corporal a través de DEXA, variables antropométricas (peso y altura y volúmenes espirométricos forzados (FEV1 and FVC. Los resultados mostraron que el grupo SC tenía unos volúmenes FEV1 y FVC superiores

  7. How Do Clinical Trials Work?

    Science.gov (United States)

    ... Studies NHLBI Trials Clinical Trial Websites How Do Clinical Trials Work? If you take part in a clinical ... protect patients and help produce reliable study results. Clinical Trial Protocol Each clinical trial has a master plan ...

  8. Informed Consent (Clinical Trials)

    Science.gov (United States)

    ... Research Cancer Treatment Types of Treatment Side Effects Clinical Trials Information A to Z List of Cancer Drugs ... Staging Prognosis Treatment Types of Treatment Side Effects Clinical Trials Cancer Drugs Complementary & Alternative Medicine Coping Feelings & Cancer ...

  9. Research Areas - Clinical Trials

    Science.gov (United States)

    Information about NCI programs and initiatives that sponsor, conduct, develop, or support clinical trials, including NCI’s Clinical Trial Network (NCTN) and NCI Community Oncology Research Program (NCORP) initiatives.

  10. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... trial is to find out if an experimental drug, therapy, medical device, lifestyle change, or test will ... disease. Phases of Clinical Trials Clinical trials of drugs are usually described based on their phase. The ...

  11. NIH Clinical Centers

    Data.gov (United States)

    Federal Laboratory Consortium — The NIH Clinical Center consists of two main facilities: The Mark O. Hatfield Clinical Research Center, which opened in 2005, houses inpatient units, day hospitals,...

  12. Evidence of clinical competence.

    Science.gov (United States)

    Lejonqvist, Gun-Britt; Eriksson, Katie; Meretoja, Riitta

    2012-06-01

    This cross-sectional research used a qualitative questionnaire to explore clinical competence in nursing. The aim was to look for evidence of how clinical competence showed itself in practice. In the research, the views from both education and working life are combined to broadly explore and describe clinical competence from the perspective of students, clinical preceptors and teachers. The questions were formulated on how clinical competence is characterised and experienced, what contributes to it and how it is maintained, and on the relation between clinical competence and evidence-based care. The answers were analysed by inductive content analysis. The results showed that clinical competence in practice is encountering, knowing, performing, maturing and improving. Clinical competence is an ongoing process, rather than a state and manifests itself in an ontological and a contextual dimension.

  13. Fertility Clinic Success Rates

    Science.gov (United States)

    ... and Autism 2013 Assisted Reproductive Technology Fertility Clinic Success Rates Report Recommend on Facebook Tweet Share Compartir 2013 ART Fertility Clinic Success Rates Report [PDF - 1MB] Bookmarks and thumbnails are ...

  14. Clinical Laboratory Fee Schedule

    Data.gov (United States)

    U.S. Department of Health & Human Services — Outpatient clinical laboratory services are paid based on a fee schedule in accordance with Section 1833(h) of the Social Security Act. The clinical laboratory fee...

  15. Spina Bifida Clinic Directory

    Science.gov (United States)

    ... edu Special Health Care Services Spinal Cord Clinic Wesley Medical Arts Tower Building (pediatric-will refer adults) ... to age 25) Clinic 6L, One Medical Center Dr. Lebanon, NH 03756 (603) 653-9623 http://chad. ...

  16. The optimal exhaled concentration of sevoflurane for intubation without neuromuscular blockade using clinical bolus doses of remifentanil

    Science.gov (United States)

    Goo, Eui-Kyoung; Lee, Jong Seok; Koh, Jae Chul

    2017-01-01

    Abstract Background: The aim of this study was to investigate the optimal exhaled sevoflurane concentration that produces adequate endotracheal intubation conditions when sevoflurane is combined with the different bolus doses of remifentanil used in clinical practice. Methods: The patients were randomized to 3 groups (groups 1.0, 1.5, and 2.0), receiving remifentanil bolus doses of 1.0, 1.5, and 2.0 μg/kg, respectively. For each group, the concentration of sevoflurane used for each consecutive patient was increased or decreased using the “up-and-down” method based on the success or failure to achieve adequate conditions for intubation in the previous patient. The remifentanil bolus dose was administered 90 s before intubation and after the target sevoflurane concentration was achieved. Results: In groups 1.0, 1.5, and 2.0, the effective concentration in 50% (EC50) of the sevoflurane concentration required to perform successful intubation was 3.0, 2.0, and 1.29 vol% and the effective concentration in 95% was 3.45, 2.91, and 1.89 vol%, respectively. When sevoflurane was administered for the induction, the increase in heart rate (HR) of group 1.0 was the highest among the groups. The highest number of adverse events occurred in group 2.0, including vocal cord rigidity, hypotension, and bradycardia. Discussion: The EC50 of the sevoflurane concentration was 3.0, 2.0, and 1.29 vol% when it was combined with a bolus dose of remifentanil of 1.0, 1.5, and 2.0 μg/kg, respectively. Of the 3 different bolus doses of remifentanil, the dose of 1.5 μg/kg was least associated with changes in the HR/mean blood pressure during intubation without increasing adverse effects. PMID:28248887

  17. The Clinical Method and the Clinical Dilemmas.

    Directory of Open Access Journals (Sweden)

    Luis Alberto Corona Martinez

    2011-10-01

    Full Text Available The term ‘’clinic’’, among other meanings, refers to any information that suggests the presence of an illness and is obtained through questioning and physical examination processes that take place in the course of doctor-patient relationship. The purpose of this article is to summarize the challenges and dilemmas to be considered by students and young doctors in the patient's clinical approach, which completes the vision of the unquestionable positive role of clinical medical diagnosis. Different factors that can diminish the quality of obtained clinical information, thus interfering with the diagnostic process, have been classified into four groups: dependent on disease process, dependent on the individual patient or the source of information, dependent on the setting where information was obtained and dependent on the physician. As a generalization we state that the existence of the so-called challenges or dilemmas in clinical approach imply limitations to the clinical information obtained to be used with total reliability. Nevertheless, these dilemmas do not detract, nor even slightly, the values of clinical approach in the diagnostic process.

  18. University cardiology clinic.

    Science.gov (United States)

    Borozanov, V

    2013-01-01

    In distant 1972, within framework of the Internal Clinic, a cardiologic department was organized which was soon, on 29.XII.1974, transformed into the Cardiology Clinic, later the Institute for Heart Diseases, and in 2008 was renamed the University Cardiology Clinic. The greater part of its foundation was possible owing to Prof. Dimitar Arsov and Prof. Radovan Percinkovski, who was the clinic's first director in the period from 1974 to 1984. In 1985, the Clinic moved into its own new building, and in that way was physically detached from the Internal Clinics. Until its move to the new building, the Clinic functioned in the Internal Clinics building, organized as an outpatient polyclinic and inpatient infirmary department with clinical beds, a coronary intensive care unit and a haemodynamics laboratory equipped with the most modern equipment of that time. Today the Clinic functions through two integral divisions: an inpatient infirmary department which comprises an intensive coronary care unit and fourteen wards which altogether have 139 clinical beds, and the diagnostic centre which comprises an emergency clinic and day hospital, a communal and consultative outpatients' clinic functioning on a daily basis, through which some 300-350 patients pass every day, and diagnostic laboratories with a capacity of nearly 100 non-invasive and 20-30 invasive diagnostic procedures daily. The Clinic is a teaching base, and its doctors are educators of students at the Medical, Dental and Pharmacy Faculties, and also of students at the High School for Nurses and X-ray technicians, but also for those in Internal Medicine and especially Cardiology. The Clinic is also a base for scientific Masters' and post-doctoral studies, and such higher degrees are achieved not only by doctors who work here, but also by doctors from Medical Centres both in the country and abroad. Doctors working in this institution publish widely, not only a great number of books and monographs, but also original

  19. Substituting environmentally relevant flame retardants: assessment fundamentals. Vol. 3: toxicological and ecotoxicological substance profiles of selected flame retardants; Erarbeitung von Bewertungsgrundlagen zur Substitution umweltrelevanter Flammschutzmittel. Bd. 3: Toxikologisch-oekotoxikologische Stoffprofile ausgewaehlter Flammschutzmittel

    Energy Technology Data Exchange (ETDEWEB)

    Leisewitz, A.; Kruse, H.; Paulsen, O.; Schau, C.; Wieben, M.; Boehde, U.

    2001-04-01

    The study examines the status, trends and alternatives (substitution and reduction potentials) in the use of flame retardants in selected product sectors: construction; electronics and electrical engineering; rail vehicles; textiles/upholstery. In addition, the study characterises thirteen flame retardants in terms of material flows, applications and toxicology/ecotoxicology. Vol. I: Summary overview of flame retardant applications in Germany in 1999/2000; characterisation of 13 flame retardants in terms of substance properties and application-specific characteristics, range of applications and quantities; derivation of assessment fundamentals for flame retardants, focussing on toxicology/ecotoxicology, suitability for closed-loop substance management, and potential for substitution and reduction; summary assessment of 13 flame retardants; summary overview of flame retardant applications. Vol. II: Analysis of flame retardant applications (state of the art, trends, alternatives) in: unsaturated polyester (UP) resins (rail vehicles); polyurethane (PU) insulating foams and one component foams (OCF) (construction sector); plastics for generic uses in electronic and electrical equipment, in casings for electronic and electrical equipment and in printed circuit boards (electronics/electrical engineering); and in upholstery and mattresses (textile applications). Vol. III: Toxicological/ecotoxicological profiles of substances: Decabromodiphenyl oxide; Tetrabromobisphenol A; Bis[pentabromophenyl]ethane; Hexabromocyclodo-decane, Tris[chloropropyl]phosphate, Resorcinol-bis-diphenylphosphate; N-Hydroxymethyl-3-dimethylphosphonopropionamide, Red phosphorus, Ammonium polyphosphate, Melamin cyanurate, Aluminiumtrihydroxide, Sodium borate decahydrate, Antimony trioxide. (orig.) [German] Untersucht werden Stand, Trends und Alternativen (Substitutions- und Minderungspotentiale) beim Einsatz von Flammschutzmitteln (FSM) in ausgewaehlten Produkten aus: Baubereich, Elektrotechnik

  20. Volatile profile of the headspace fraction of "assa-peixe" (Vernonia sp. honeys Perfil dos compostos voláteis presentes na fração "headspace" de méis de assa-peixe

    Directory of Open Access Journals (Sweden)

    Mariana Carvalho Ribeiro

    2008-03-01

    Full Text Available The volatile compounds were isolated from the headspace fraction of "assa-peixe" honeys by adsorptive column chromatography, eluted with acetone and analysed by GC-FID and GC-MS. Volatile compounds were separated using a polar phase column. Low- and medium-boiling point volatile compounds predominated in the headspace. A large proportion of 3-penten-2-one (80.5 ± 13.9 µg.kg-1 and benzaldehyde (25.9 ± 4.2 µg.kg-1 was found in the headspace fraction, while 2-penten-1-ol, 3-hexenyl butanoate, octadecane and hexanoic acid (Os compostos voláteis da fração "Headspace" de méis de assa-peixe foram adsorvidos pela técnica de cromatografia de adsorção, eluídos com acetona e analisados através da CG/DIC e CG/EM usando coluna polar de sílica fundida. Os compostos voláteis de baixo e médio ponto de ebulição predominaram na fração "headspace". Foi achada uma grande proporção de 3-penten-2-ona (80,5 ± 13,9 µg.kg-1 e benzaldeído (25,9 ± 4,2 µg.kg-1, enquanto o 2-penten-1-ol, o hexanoato de 3-hexenila, o octadecano e o ácido hexanóico (<0,01 µg.kg-1 foram compostos minoritários. Um total de doze compostos voláteis foi identificado, sendo cinco descritos pela primeira vez no mel de assa-peixe. Destes cinco, a 3-penten-2-ona, o dodecano, o tridecano e o benzaldeído foram definitivamente identificados na fração "headspace" dos méis de assa-peixe brasileiro.

  1. Alelopatia de extratos voláteis na germinação de sementes e no comprimento da raiz de alface Allelopathy of plant volatile extracts on seed germination and radicle length of lettuce

    Directory of Open Access Journals (Sweden)

    Maria da Conceição Sampaio Alves

    2004-11-01

    Full Text Available O objetivo deste trabalho foi identificar possíveis efeitos alelopáticos de extratos voláteis de óleos essenciais na germinação e no comprimento da raiz de plântulas de alface. Foram utilizadas cinco concentrações de cada óleo (0,0, 0,001, 0,01, 0,1 e 1,0%, v/v, em delineamento inteiramente casualizado, com quatro repetições de 25 sementes de alface. Os extratos voláteis de óleos essenciais de canela, alecrim-pimenta, capim-citronela e alfavaca-cravo evidenciaram potencialidades alelopáticas na germinação e comprimento das raízes de plântulas de alface, efeitos que variaram de acordo com a concentração do óleo. O extrato volátil de óleo de jaborandi estimula o crescimento da radícula e não provoca inibição da germinação de sementes de alface, caracterizando-se como de efeito alelopático benéfico.The objective of this work was to identify allelopathic effects of volatile extracts of essential oils on germination and radicle length of lettuce seedlings. Five concentrations were utilized for each oil (0.0, 0.001, 0.01, 0.1 and 1.0%, v/v arranged into a completely randomized design with four replicates of 25 seeds. The volatile extracts of essential oils of cinnamon, alecrim-pimenta, capim-citronela and alfavaca-cravo revealed allelopathic potentialities on lettuce seed germination and radicle growth, effect which varied according to the oil concentration. The volatile extract of Jaborandi essential oil stimulates radicle growth and does not inhibit lettuce seeds germination, which is characterized as a beneficial allelopathic effect.

  2. Volume replacement with hydroxyethyl starch or Ringer lactate solution in hemorrhagic gastroenteritis dogs with parvovirusReposição volêmica com hidroxietilamido ou solução de ringer lactato em cães com gastroenterite hemorrágica por parvovírus

    Directory of Open Access Journals (Sweden)

    Eduardo Ghiggi

    2013-09-01

    Full Text Available Parvovirus is an infectious viral disease, highly contagious, affecting dogs causing acute enteritis. Dehydration is a minor problem and acute evolution, which is the main focus of treatment. The objective of this study was to evaluate two treatments volume replacement in dogs with confirmed diagnosis of parvovirus infection by antigen detection in stool by ELISA. A total of 15 dogs, mixed, male and female, aged from 3 to 6 months, these four they had died during treatment and 11 were included in the study. Patients were randomly divided into two groups: hydroxyethyl starch 130/0.4 (HES, n=6 and Group Ringer Lactate (RL, n=5, which received fluid resuscitation with hydroxyethyl starch 130/0.4 and Ringer’s solution lactate, respectively, based on calculations of fluid deficit. All animals received intravenously: cephalothin, metronidazole, ranitidine and metoclopramide. During hospitalization, every 12 hours were evaluated arterial blood gas, electrolyte dosing and clinical examination (heart rate, respiratory rate, rectal temperature, capillary refill time, vomiting, appetite, dehydration, weight gain, hematochezia, melena, hematemesis and presence abdominal pain and 24 hours each blood count was performed. In group RL was increase in the values of PaO2 and decreases in hemoglobin, hematocrit, phosphorus and magnesium, and group HES, a decrease in the percentage of dehydration, hemoglobin, phosphorus and potassium. There were no differences in other parameters between the groups. Both treatments were effective in fluid replacement of patients, no difference in any variable analyzed. A parvovirose é uma doença infecciosa viral, altamente contagiosa, que acomete cães causando enterite aguda. A desidratação é um problema secundário e de evolução aguda, sendo este o foco principal do tratamento. O objetivo deste estudo foi avaliar dois tratamentos de reposição volêmica em cães com diagnóstico confirmado de parvovirose por detec

  3. AFRRI (Armed Forces Radiobiology Research Institute) Reports, April - June 1986.

    Science.gov (United States)

    1986-01-01

    monkey measured by hydrogen clearance. Stroke 5:512-517. Metcalfe, D. D., Kaliner, M., and Donlon, M. A. 1981. The mast cell. In CRC Critical Reviews in...H2 clearance measurement of blood flow: A review of technique and polaro- graphic principles. Stroke 11:552-564. Received lune 28, 1985 Revised...receptors of the nucleus accumbens or closely adjacent structures. In most species a large dose of morphine produces catatonia duced hyperactivity (Akil

  4. Systems biology and its potential role in radiobiology.

    Science.gov (United States)

    Feinendegen, Ludwig; Hahnfeldt, Philip; Schadt, Eric E; Stumpf, Michael; Voit, Eberhard O

    2008-02-01

    About a century ago, Conrad Röentgen discovered X-rays, and Henri Becquerel discovered a new phenomenon, which Marie and Pierre Curie later coined as radio-activity. Since their seminal work, we have learned much about the physical properties of radiation and its effects on living matter. Alas, the more we discover, the more we appreciate the complexity of the biological processes that are triggered by radiation exposure and eventually lead (or do not lead) to disease. Equipped with modern biological methods of high-throughput experimentation, imaging, and vastly increased computational prowess, we are now entering an era where we can piece some of the multifold aspects of radiation exposure and its sequelae together, and develop a more systemic understanding of radiogenic effects such as radio-carcinogenesis than has been possible in the past. It is evident from the complexity of even the known processes that such an understanding can only be gained if it is supported by mathematical models. At this point, the construction of comprehensive models is hampered both by technical inadequacies and a paucity of appropriate data. Nonetheless, some initial steps have been taken already and the generally increased interest in systems biology may be expected to speed up future progress. In this context, we discuss in this article examples of relatively small, yet very useful models that elucidate selected aspects of the effects of exposure to ionizing radiation and may shine a light on the path before us.

  5. Radiobiological experiments with plant seeds aboard the biosatellite Kosmos 1887

    Science.gov (United States)

    Anikeeva, I. D.; Vaulina, E. N.; Kostina, L. N.; Marenny, A. M.; Portman, A. I.; Rusin, S. V.; Benton, E. V.

    1990-01-01

    The effects of spaceflight factors on the seeds of Arabidopsis thaliana and Crepis capillaris were studied provided with various protective measures: the seeds were located inside the satellite and in open space, protected with aluminium foil and also exposed without the foil cover. When the seeds were in open space without any protection, their viability was found to be suppressed; the survival rate and fertility of plants grown from these seeds were also diminished. An increase in the frequency of chromosome aberrations (CA) and in the number of multiple injuries was registered in this case. Experiments with the aluminium foil shielding showed a decrease in the suppression of the seeds' viability, but mutational changes were found to be even more increased, while the survival and fertility of the plants decreased. An increase in the thickness of shielding resulted in a decrease in the effects up to the level of the control, except for the effects connected with CA and fertility of the plants. Analysis of the results shows that these impairments can be ascribed to the action of single heavy charged particles (HCP). The seeds can be thus regarded as an integral biological 'dosimeter' which allows estimation of the total effects of radiation, ecological and biological factors.

  6. AFRRI (Armed Forces Radiobiology Research Institute) Reports, January- March 1986

    Science.gov (United States)

    1986-03-01

    similar to human systemic lupus erythematosus ) also exhibit a second type of K+ channel [7]. This channel activates at more positive potentials...depolarization, the time to peak was reduced (Fig. 95). The time course of the rise of the outward current was not systematically investigated because the... systematic voltage dependence at voltages positive to -25 mV. In two cells studied at potentials negative to -25, the rate of decay clearly decreased

  7. The contribution of women to radiobiology: Marie Curie and beyond.

    Science.gov (United States)

    Gasinska, Anna

    2016-01-01

    Marie Sklodowska-Curie, an extraordinary woman, a Polish scientist who lived and worked in France, led to the development of nuclear energy and the treatment of cancer. She was the laureate of two Nobel Prizes, the first woman in Europe who obtained the degree of Doctor of Science and opened the way for women to enter fields which had been previously reserved for men only. As a result of her determination and her love of freedom, she has become an icon for many female scientists active in radiation sciences. They are successors of Maria Curie and without the results of their work, improvement in radiation oncology will not be possible. Many of them shared some elements of Maria Curie's biography, like high ethical and moral standards, passionate dedication to work, strong family values, and scientific collaboration with their husbands. The significance of Tikvah Alper, Alma Howard, Shirley Hornsey, Juliana Denekamp, Helen Evans, Eleanor Blakely, Elizabeth L. Travis, Fiona Stewart, Andree Dutreix, Catharine West, Peggy Olive, Ingela Turesson, Penny Jeggo, Irena Szumiel, Eleonor Blakely, Sara Rockwell and Carmel Mothersill contribution to radiation oncology is presented. All the above mentioned ladies made significant contribution to the development of radiotherapy (RT) and more efficient cancer treatment. Due to their studies, new schedules of RT and new types of ionizing radiation have been applied, lowering the incidence of normal tissue toxicity. Their achievements herald a future of personalized medicine.

  8. Radiobiological experiments with plant seeds aboard the biosatellite Cosmos 1887

    Science.gov (United States)

    Benton, E. V.; Anikeeva, I. D.; Akatov, Yu. A.; Vaulina, E. N.; Kostina, L. N.; Marenny, A.; Portman, A. I.; Rusin, S. V.

    1995-01-01

    The effects of spaceflight factors on the seeds of Arabidopsis thaliana and Crepis capillaris were studied. The seeds were located inside the satellite in an open space, protected with aluminum foil and also exposed without the foil cover. When the seeds were in open space without any protection, their viability was found to be suppressed; the survival rate and fertility of plants grown from these seeds were also diminished. An increase in the frequency of chromosome aberrations (CA) and in the number of multiple injuries was registered in this case. Experiments with the aluminum foil shielding showed a decrease in the suppression of the seeds' viability, but mutational changes were found to be even more increased, while the survival rate and fertility of the plants decreased. An increase in the thickness of shielding resulted in a decrease in the effects up to the level of the control, except for the effects connected with CA and fertility of the plants. Analysis of the results shows that these impairments can be ascribed to the action of single heavy charged particles (HCP). The seeds can thus be regarded as an integral biological 'dosimeter' which allows estimation of the total effects of radiation, ecological and biological factors.

  9. Preparation of laser-accelerated proton beams for radiobiological applications

    Energy Technology Data Exchange (ETDEWEB)

    Metzkes, J., E-mail: j.metzkes@fzd.de [Forschungszentrum Dresden-Rossendorf (FZD), 01314 Dresden (Germany); Cowan, T.E. [Forschungszentrum Dresden-Rossendorf (FZD), 01314 Dresden (Germany); Karsch, L. [OncoRay - National Center for Radiation Research in Oncology, TU Dresden, Fetscherstr. 74, 01307 Dresden (Germany); Kraft, S.D. [Forschungszentrum Dresden-Rossendorf (FZD), 01314 Dresden (Germany); Pawelke, J.; Richter, C. [Forschungszentrum Dresden-Rossendorf (FZD), 01314 Dresden (Germany); OncoRay - National Center for Radiation Research in Oncology, TU Dresden, Fetscherstr. 74, 01307 Dresden (Germany); Richter, T.; Zeil, K. [Forschungszentrum Dresden-Rossendorf (FZD), 01314 Dresden (Germany); Schramm, U., E-mail: u.schramm@fzd.de [Forschungszentrum Dresden-Rossendorf (FZD), 01314 Dresden (Germany)

    2011-10-11

    This paper presents the concept of transport and filtering of laser-accelerated proton pulses used for the first cell irradiation experiments performed with the Dresden 150 TW laser DRACO. Based on a simple non-focusing magnetic dipole equipped with two apertures the concept makes use of an energy dependent angular asymmetry of the proton spectra. For micron thin target foils protons of interest with energies above 7 MeV are observed to be significantly offset from target normal where low energy emission is dominantly centered. As the effect can be controlled via the target rotation with respect to the incoming light, it can be used to optimize the transport efficiency for high energy protons while simultaneously suppressing background radiation.

  10. Laser-driven particle acceleration towards radiobiology and medicine

    CERN Document Server

    2016-01-01

    This book deals with the new method of laser-driven acceleration for application to radiation biophysics and medicine. It provides multidisciplinary contributions from world leading scientist in order to assess the state of the art of innovative tools for radiation biology research and medical applications of ionizing radiation. The book contains insightful contributions on highly topical aspects of spatio-temporal radiation biophysics, evolving over several orders of magnitude, typically from femtosecond and sub-micrometer scales. Particular attention is devoted to the emerging technology of laser-driven particle accelerators and their applicatio to spatio-temporal radiation biology and medical physics, customization of non-conventional and selective radiotherapy and optimized radioprotection protocols.

  11. Where Radiobiology Began in Russia: A Physician’s Perspective

    Science.gov (United States)

    2010-09-01

    nothing here to see. Here we forgot the peace pipe And found nothing else better, Than each in his shell , A woodchuck tucked into his burrow. Later...of 100x100x600 mm and had three cylindrical openings through which the 20 cylinders were inserted. The uranium for it was collected literally...building housing the furnace there was a high radiation background level. When the furnace was operating, a large red light on the roof of the building was

  12. Learning clinical reasoning.

    Science.gov (United States)

    Pinnock, Ralph; Welch, Paul

    2014-04-01

    Errors in clinical reasoning continue to account for significant morbidity and mortality, despite evidence-based guidelines and improved technology. Experts in clinical reasoning often use unconscious cognitive processes that they are not aware of unless they explain how they are thinking. Understanding the intuitive and analytical thinking processes provides a guide for instruction. How knowledge is stored is critical to expertise in clinical reasoning. Curricula should be designed so that trainees store knowledge in a way that is clinically relevant. Competence in clinical reasoning is acquired by supervised practice with effective feedback. Clinicians must recognise the common errors in clinical reasoning and how to avoid them. Trainees can learn clinical reasoning effectively in everyday practice if teachers provide guidance on the cognitive processes involved in making diagnostic decisions.

  13. Integrating clinical research into clinical decision making

    Directory of Open Access Journals (Sweden)

    Mark R Tonelli

    2011-01-01

    Full Text Available Evidence-based medicine has placed a general priority on knowledge gained from clinical research for clinical decision making. However, knowledge derived from empiric, population-based research, while valued for its ability to limit bias, is not directly applicable to the care of individual patients. The gap between clinical research and individual patient care centers on the fact that empiric research is not generally designed to answer questions of direct relevance to individual patients. Clinicians must utilize other forms of medical knowledge, including pathophysiologic rationale and clinical experience, in order to arrive at the best medical decision for a particular patient. In addition, clinicians must also elucidate and account for the goals and values of individual patients as well as barriers and facilitators of care inherent in the system in which they practice. Evidence-based guidelines and protocols, then, can never be prescriptive. Clinicians must continue to rely on clinical judgment, negotiating potentially conflicting warrants for action, in an effort to arrive at the best decision for a particular patient.

  14. Eliminación catalítica de compuestos orgánicos volátiles presentes en pequeñas y medianas empresas mediante la adaptación de extractores comerciales de aire

    OpenAIRE

    Colman Lerner, Jorge Esteban; Peluso, Miguel Ángel; Porta, Atilio Andrés; Horacio J. Thomas; Sambeth, Jorge

    2012-01-01

    El trabajo se enmarca en la modificación de un extractor de aire comercial, al cual se le colocó en la chimenea de venteo un sistema catalítico, evaluándose la eliminación de Compuestos Orgánicos Volátiles (COVs) tales como metiletilcetona, cloroformo, tolueno, m-xileno, o-xileno y p-xileno. Se estudió la actividad catalítica de sistemas en base a platino, óxido de manganeso, y óxido de manganeso dopado con Pt, todos ellos soportados sobre monolitos de bentonita. La elección de los COVs a eli...

  15. Caracterización de compuestos volátiles durante el secado por aspersión de jugo de sandía (Citrullus lanatus ThunB.)

    OpenAIRE

    Héctor Manuel González Sánchez; Salvador González Palomares; Tábata Rosales Reyes

    2011-01-01

    El objetivo del trabajo fue evaluar el efecto de la maltodextrina y goma arábiga en la retención de compuestos volátiles durante el secado por aspersión de jugo de sandía (Citrullus lanatus Thunb.). Se utilizó sandía de la variedad Alena. Se evaluaron tres tratamientos de encapsulantes, T1: 0.5% p/p de maltodextrina, T2: 0.5% p/p de goma arábiga y T3: 0.5% de una mezcla de maltodextrina DE-10 y goma arábiga (1:1) p/p. Las condiciones del secado fueron constantes: flujo de alimentación del 15%...

  16. Corrosion inhibition of 6061 Al-15 vol. pct. SiC(p) composite and its base alloy in a mixture of sulphuric acid and hydrochloric acid by 4-(N,N-dimethyl amino) benzaldehyde thiosemicarbazone

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Geetha Mable [Department of Chemistry, National Institute of Technology Karnataka, Surathkal, Srinivasnagar 575 025, Mangalore, Karnataka (India); Nayak, Jagannath [Department of Metallurgical and Materials Engineering, National Institute of Technology Karnataka, Surathkal, Srinivasnagar 575 025, Karnataka (India); Shetty, A. Nityananda, E-mail: nityashreya@gmail.com [Department of Chemistry, National Institute of Technology Karnataka, Surathkal, Srinivasnagar 575 025, Mangalore, Karnataka (India)

    2011-02-15

    Research highlights: {yields} Corrosion inhibition of Al-SiC composite. {yields} DMABT as corrosion inhibitor. {yields} Inhibition through physisorption of DMABT. - Abstract: The corrosion inhibition characteristics of 4-(N,N-dimethylamino) benzaldehyde thiosemicarbazone (DMABT) on the corrosion behavior of 6061 Al-15 vol. pct. SiC(p) composite and its base alloy were studied at different temperatures in acid mixture medium containing varying concentrations of hydrochloric acid and sulphuric acid using Tafel extrapolation technique and ac impedance spectroscopy (EIS). The effect of inhibitor concentration, temperature and concentration of the acid mixture media on the inhibitor action was investigated. It was found that inhibition efficiencies increase with the increase in inhibitor concentration, but decrease with the increase in temperature and with the increase in concentration of the acid media. Thermodynamic parameters for dissolution process were determined. The adsorption of DMABT on both the composite and base alloy was found to be through physisorption obeying Freundlich adsorption isotherm.

  17. Pegylated G-CSF Inhibits Blood Cell Depletion, Increases Platelets, Blocks Splenomegaly, and Improves Survival after Whole-Body Ionizing Irradiation but Not after Irradiation Combined with Burn

    Science.gov (United States)

    2014-03-05

    AFRRI: Armed Forces Radiobiology Research Institute CI: Combined injury i.p.: Intraperitoneal p.o.: Oral gavage Peg-G-CSF: Pegylated granulocyte...survival of mice with systemic candidiasis ,” Cytokine, vol. 12, no. 6, pp. 666–670, 2000. [20] K. J. Neelis, S. C. C. Hartong, T. Egeland, G. R. Thomas, D

  18. Clinical research informatics

    CERN Document Server

    Richesson, Rachel L

    2012-01-01

    This book provides foundational coverage of key areas, concepts, constructs, and approaches of medical informatics as it applies to clinical research activities, in both current settings and in light of emerging policies. The field of clinical research is fully characterized (in terms of study design and overarching business processes), and there is emphasis on information management aspects and informatics implications (including needed activities) within various clinical research environments. The purpose of the book is to provide an overview of clinical research (types), activities, and are

  19. American Association for Clinical Chemistry

    Science.gov (United States)

    ... Education Credits Certification Resources Career Guidance Publications Clinical Chemistry Clinical Laboratory News The Journal of Applied Laboratory Medicine Clinical and Forensic Toxicology News Clinical Laboratory Marketplace Books and Multimedia ...

  20. Fine needle aspiration cytology findings in cases diagnosed as oropharyngeal tularemia lymphadenitis (Erratum was published in Vol 24 Number 1, 2008

    Directory of Open Access Journals (Sweden)

    Banu DOĞAN GÜN

    2007-01-01

    Full Text Available Francisella tularensis is a gram-negative coccobacilus that causes zoonotic disease tularemia. Histopathological examination of lymph node biopsy in tularemia reveals suppurative granulomatous inflammation potentially associated caseous necrosis. Diagnosis is mainly made on the evidence of elevated agglutinating antibodies against F. Tularensis. In this study we aimed to evaluate the cytological features of ulceroglandular tularemia cases and to demonstrate the role of fine needle aspiration cytology in the diagnosis of tularemia.Fine needle aspiration cytology findings of six cervical lymphadenopaties that had established diagnoses of tularemia both clinically and serologically, were evaluated and the cytomorphological features were described.All of the cases revealed suppurative inflammation and some caseous necrosis and in four cases epithelioid histiocytes and multinuclear giant cells were observed additionally.The differential diagnosis of tularemia principally from tuberculosis and other types of bacterial lymphadenitis was made and the place of fine needle aspiration cytology among other diagnostic laboratory tests for tularemia was evaluated.

  1. Anne Bysted, Carsten Selch Jensen, Kurt Villads Jensen, John H. Lind, Jerusalem in the North: Denmark and the Baltic Crusades, 1100–1522 (Outremer: Studies in the Crusades and the Latin East, vol. 1), Brepols, Turnhout 2012, 393 pp.+ 57 figures and 5 maps

    OpenAIRE

    Czaja, Roman

    2016-01-01

    Anne Bysted, Carsten Selch Jensen, Kurt Villads Jensen, John H. Lind, Jerusalem in the North: Denmark and the Baltic Crusades, 1100–1522 (Outremer: Studies in the Crusades and the Latin East, vol. 1), Brepols, Turnhout 2012, 393 pp. + 57 figures and 5 maps, ISBN: 978-2-503-52325-5.

  2. Predictors of Clinical Performance

    Science.gov (United States)

    Turner, Edward; And Others

    1974-01-01

    In a search for predictors of clinical competence, 50 third-year medical students studying pediatrics were videotaped during their interview and physical examination of outpatients. Consideration should be given to the possible value of psychological tests as predictors of clinical competence. (Author)

  3. Developing Clinical Competence

    NARCIS (Netherlands)

    P.F. Wimmers (Paul)

    2006-01-01

    textabstractThe development of clinical competence is the main purpose of medical education. The long road to become clinically competent starts on the first day of medical school, and every institution strives to select the best students. The responsibility of medical schools is to train th

  4. Overview of clinical cytogenetics.

    Science.gov (United States)

    Korf, B R

    2001-08-01

    This unit provides an introduction to clinical cytogenetics. It opens with indications for prenatal and postnatal chromosome analysis, followed by a brief discussion of the applications of fluorescence in situ hybridization (FISH). It suggests tissue sources for prenatal and postnatal analysis, and closes with a review of numerical and structural chromosome abnormalities. This unit provides an introduction to clinical cytogenetics.

  5. Clinical Trial Basics

    Science.gov (United States)

    ... How Am I Protected? Mark Bowden / iStock Ethical guidelines The goal of clinical research is to develop knowledge that improves human ... data and decide whether the results have medical importance. Results from clinical trials are often published in peer-reviewed scientific ...

  6. [Arthritis and clinical history].

    Science.gov (United States)

    Silva, Lígia; Sampaio, Luzia; Pinto, José; Ventura, Francisco S

    2011-01-01

    In front of a patient with arthritis, clinical good-sense tells that the most probable diagnosis are the most prevalent ones. Nevertheless, we have to exclude a multiplicity of other aetiologies, less frequent, but with highest implications in the therapeutic conduct. Infections by Brucella and by Borrelia are rare causes of chronic arthritis, yet are diagnosis to consider, even when the clinical manifestations aren't the most typical, as there still exist endemic areas in Portugal. Here we report two clinical cases about patients with arthritis for more than one year, subject to ineffective exams ant treatments. Only the clinical history could put on evidence clinical-epidemiological data, suggestive of Brucellosis and Lyme Disease, namely the professional contact with infected animals, and the history of probable erythema migrans, that pointed toward the correct diagnosis. So, with directed therapeutic, there was complete resolution of the inflammatory symptoms.

  7. The new clinical leader.

    Science.gov (United States)

    Oates, Kim

    2012-06-01

    The complexity and cost of health care, along with a greater need for accountability calls for a new style of clinical leadership. The new clinical leader will lead reform by putting the needs of the patient first and foremost, looking at current and planned services from the patient's point of view as well as the clinician's. Excellent clinical skills will remain essential but will be supplemented by a focus on team work and mentoring, patient safety, clear communication and reduction in waste and inefficiency, leading to better financial outcomes. The new clinical leaders will understand the importance of consulting widely and engaging colleagues in creating change to improve patient care. They will develop trusting and mutually respectful relationships with health service management and be able to negotiate the delicate balance between clinical judgement, resource constraints and personal loyalties by keeping the best outcome for the patient at the forefront of their thinking.

  8. Clinical Pathway for Thyroidectomy.

    Science.gov (United States)

    Villar del Moral, Jesús María; Soria Aledo, Víctor; Colina Alonso, Alberto; Flores Pastor, Benito; Gutiérrez Rodríguez, María Teresa; Ortega Serrano, Joaquín; Parra Hidalgo, Pedro; Ros López, Susana

    2015-05-01

    Clinical pathways are care plans applicable to patient care procedures that present variations in practice and a predictable clinical course. They are designed not as a substitute for clinical judgment, but rather as a means to improve the effectiveness and efficiency of the procedures. This clinical pathway is the result of a collaborative work of the Sections of Endocrine Surgery and Quality Management of the Spanish Association of Surgeons. It attempts to provide a framework for standardizing the performance of thyroidectomy, the most frequently performed operation in endocrine surgery. Along with the usual documents of clinical pathways (temporary matrix, variance tracking and information sheets, assessment indicators and a satisfaction questionnaire) it includes a review of the scientific evidence around different aspects of pre, intra and postoperative management. Among others, antibiotic and antithrombotic prophylaxis, preoperative preparation in hyperthyroidism, intraoperative neuromonitoring and systems for obtaining hemostasis are included, along with management of postoperative hypocalcemia.

  9. Situated clinical cognition.

    Science.gov (United States)

    Timpka, T

    1995-10-01

    The features characterizing study of clinical cognition in situ are formulated as: Re-cognition of context, culture, history and affect. Socializing and phenomenalistic elements are again included in the research agenda. Interest for representations: an analysis level is reserved for the symbols, rules and images relevant to define in models of clinical cognition. De-emphasis on computer modeling: investigations focus on the 'functional systems' in which computers are involved. Rootedness in classical philosophical problems: issues concerning situated clinical cognition are connected to the width of available theoretical literature. Belief in interdisciplinary studies: productive interactions between the new and traditional disciplines is anticipated, implying that new shared methods have to be developed. When scientific perspectives are broadened, a new balance has to be found between the relevance of the subject of study and methodological rigor. The situated clinical cognition framework is to allow for moving between models, theories, and perspectives, as it does not presuppose a singular model of clinical thinking.

  10. Collaboration across clinical silos.

    Science.gov (United States)

    Mohler, M Jane

    2013-01-01

    We face significant challenges to healthcare integration as well as tremendous opportunities to advance healthcare reform as we endeavor to provide a coordinated continuum of high-value services to defined populations for which we are clinically and fiscally accountable. As we move away from fee-for-service and poorly coordinated care toward value-based and bundled care, systems such as UnityPoint Health and clinical entities such as Piedmont Heart are leading the way, breaking down their clinical silos, improving value and access, and gaining patient loyalty. Evidence points us to sound principles that can inform the clinical integration process. Health systems must reinvent themselves, reengineer clinical operations, and streamline processes, all of which require collaboration across traditional silos, both inside our organizations and outside into our wider communities, to ensure that our patients receive the safe, high-value care they deserve.

  11. Gait analysis: clinical facts.

    Science.gov (United States)

    Baker, Richard; Esquenazi, Alberto; Benedetti, Maria G; Desloovere, Kaat

    2016-08-01

    Gait analysis is a well-established tool for the quantitative assessment of gait disturbances providing functional diagnosis, assessment for treatment planning, and monitoring of disease progress. There is a large volume of literature on the research use of gait analysis, but evidence on its clinical routine use supports a favorable cost-benefit ratio in a limited number of conditions. Initially gait analysis was introduced to clinical practice to improve the management of children with cerebral palsy. However, there is good evidence to extend its use to patients with various upper motor neuron diseases, and to lower limb amputation. Thereby, the methodology for properly conducting and interpreting the exam is of paramount relevance. Appropriateness of gait analysis prescription and reliability of data obtained are required in the clinical environment. This paper provides an overview on guidelines for managing a clinical gait analysis service and on the principal clinical domains of its application: cerebral palsy, stroke, traumatic brain injury and lower limb amputation.

  12. Clinical Research Methodology 2: Observational Clinical Research.

    Science.gov (United States)

    Sessler, Daniel I; Imrey, Peter B

    2015-10-01

    Case-control and cohort studies are invaluable research tools and provide the strongest feasible research designs for addressing some questions. Case-control studies usually involve retrospective data collection. Cohort studies can involve retrospective, ambidirectional, or prospective data collection. Observational studies are subject to errors attributable to selection bias, confounding, measurement bias, and reverse causation-in addition to errors of chance. Confounding can be statistically controlled to the extent that potential factors are known and accurately measured, but, in practice, bias and unknown confounders usually remain additional potential sources of error, often of unknown magnitude and clinical impact. Causality-the most clinically useful relation between exposure and outcome-can rarely be definitively determined from observational studies because intentional, controlled manipulations of exposures are not involved. In this article, we review several types of observational clinical research: case series, comparative case-control and cohort studies, and hybrid designs in which case-control analyses are performed on selected members of cohorts. We also discuss the analytic issues that arise when groups to be compared in an observational study, such as patients receiving different therapies, are not comparable in other respects.

  13. Clinical PET application

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Moo; Hong, Song W.; Choi, Chang W.; Yang, Seong Dae [Korea Cancer Center Hospital, Seoul (Korea)

    1997-12-01

    PET gives various methabolic images, and is very important, new diagnostic modality in clinical oncology. In Korea Cancer Center Hospital, PET is installed as a research tool of long-mid-term atomic research project. For the efficient use of PET for clinical and research projects, income from the patients should be managed to get the raw material, equipment, manpower, and also for the clinical PET research. 1. Support the clinical application of PET in oncology. 2. Budgetary management of income, costs for raw material, equipment, manpower, and the clinical PET research project. In this year, 250 cases of PET images were obtained, which resulted total income of 180,000,000 won. 50,000,000 won was deposited for the 1998 PET clinical research. Second year PET clinical research should be managed under unified project. Increased demand for {sup 18}FDG in and outside KCCH need more than 2 times production of {sup 18}FDG in a day purchase of HPLC pump and {sup 68}Ga pin source which was delayed due to economic crisis, should be done early in 1998. (author). 2 figs., 3 tabs.

  14. Clinical microbiology informatics.

    Science.gov (United States)

    Rhoads, Daniel D; Sintchenko, Vitali; Rauch, Carol A; Pantanowitz, Liron

    2014-10-01

    The clinical microbiology laboratory has responsibilities ranging from characterizing the causative agent in a patient's infection to helping detect global disease outbreaks. All of these processes are increasingly becoming partnered more intimately with informatics. Effective application of informatics tools can increase the accuracy, timeliness, and completeness of microbiology testing while decreasing the laboratory workload, which can lead to optimized laboratory workflow and decreased costs. Informatics is poised to be increasingly relevant in clinical microbiology, with the advent of total laboratory automation, complex instrument interfaces, electronic health records, clinical decision support tools, and the clinical implementation of microbial genome sequencing. This review discusses the diverse informatics aspects that are relevant to the clinical microbiology laboratory, including the following: the microbiology laboratory information system, decision support tools, expert systems, instrument interfaces, total laboratory automation, telemicrobiology, automated image analysis, nucleic acid sequence databases, electronic reporting of infectious agents to public health agencies, and disease outbreak surveillance. The breadth and utility of informatics tools used in clinical microbiology have made them indispensable to contemporary clinical and laboratory practice. Continued advances in technology and development of these informatics tools will further improve patient and public health care in the future.

  15. SU-F-19A-11: Retrospective Evaluation of Thermal Coverage by Thermobrachytherapy Seed Arrangements of Clinical LDR Prostate Implants

    Energy Technology Data Exchange (ETDEWEB)

    Warrell, G; Shvydka, D; Chen, C; Parsai, E [University of Toledo Medical Center, Toledo, OH (United States)

    2014-06-15

    Purpose: The superiority of a properly-administered combination of radiation therapy and hyperthermia over radiation alone in treatment of human cancers has been demonstrated in multiple studies examining radiobiology, local control, and survival. Unfortunately, hyperthermia is not yet a common modality in oncology practice, due in part to the technical difficulty of heating a deep-seated target volume to sufficient temperature. To address this problem, our group has invented a thermobrachytherapy (TB) seed based on a commonly-used low dose-rate permanent brachytherapy seed for implant in solid tumors. Instead of the tungsten radiographic marker of the standard seed, the TB seed contains one of a self-regulating ferromagnetic alloy. Placement of a patient implanted with such seeds in an oscillating magnetic field generates heat via induction of eddy currents. We present the results of studies of the capability of clinically-realistic TB seed arrangements to adequately heat defined target volumes. Methods: Seed distributions for several past LDR prostate permanent implant brachytherapy patients were reproduced in the finite element analysis software package COMSOL Multiphysics 4.4, with the difference that TB seeds were modelled, rather than the radiation-only seeds actually used for their treatments. The implant geometries were mainly of the modified peripheral loading type; a range of prostatic volumes and blood perfusion rates likely to be seen in a clinical setting were examined. Results: According to the simulations, when distributed to optimize radiation dose, TB seeds also produce sufficient heat to provide thermal coverage of the target given proper selection of the magnetic field strength. However, the thermal distributions may be improved by additional use of hyperthermia-only seeds. Conclusion: A dual-modality seed intended as an alternative to and using the same implantation apparatus and technique as the standard LDR permanent implant seed has been

  16. Influencia de la alteración meteórica de dos carbones coquizables con contenido medio de materia volátil en la calidad del coque producido

    Directory of Open Access Journals (Sweden)

    Casal, M. D.

    1998-02-01

    Full Text Available The study of the weathering of two bituminous coals stored at the INCAR stockyard and its influence on coke quality is presented. These coals of similar rank are present in industrial blends used by the Corporación Siderúrgica Integral (CSI for the production of blast-furnace coke. Of all the techniques used to determine the degree of weathering, via thermoplastic properties, Gieseler plastometry was found to be the most sensitive. Coking tests were carried out in the semi-industrial coking plant at INCAR. The effect of weathering on each coal series is completely different. Weathering produces a loss of maximum fluidity accompanied by a decrease in aliphatic hydrogen in both coals. However, the loss rate is different in each case. Coke quality clearly decreases in one, while in the other improves at first but then gradually deteriorates. An improvement in coke quality due to weathering not only affects some high-volatile coals as it is well known but also medium volatile coals.

    Se presenta el estudio de la alteración meteórica de dos carbones bituminosos con contenido medio de materia volátil y de diferente origen geográfico, que han sido almacenados a la intemperie en el Parque del INCAR. Ambos carbones son constituyentes de las mezclas de carbones coquizables utilizadas por la Corporación Siderúrgica Integral (CSI para la producción de coque de horno alto. Entre las técnicas utilizadas para detectar el grado de meteorización de dichos carbones, la fluidez máxima Gieseler es el indicador más sensible para detectar la pérdida de propiedades plásticas. Ambas series de carbones presentan diferente comportamiento frente a la meteorización. Si bien la alteración meteórica provoca una pérdida de fluidez máxima con el tiempo de almacenamiento, debido a una pérdida de hidrógeno alifático en los dos carbones, ésta se produce a diferente velocidad. Estas diferencias se ponen de manifiesto en la calidad de los coques

  17. Mindfulness and clinical psychology.

    Science.gov (United States)

    Childs, David

    2011-09-01

    Does mindfulness offer more to psychology than a useful therapeutic technique? This paper argues that it can also establish a state of presence which is understood in relation to the practice of phenomenology. Mindfulness is then both linked to a Western intellectual tradition and offers that tradition a systematic method. This is an opening for psychological investigation of the non-conceptual basis of everyday experience. The combination of this theoretical stance with the increasingly widespread practical training of clinical psychologists in mindfulness has broad implications for clinical practice; this is illustrated in relation to the descriptive approach to clinical problems, qualitative research, and reflective practice.

  18. Automation in Clinical Microbiology

    Science.gov (United States)

    Ledeboer, Nathan A.

    2013-01-01

    Historically, the trend toward automation in clinical pathology laboratories has largely bypassed the clinical microbiology laboratory. In this article, we review the historical impediments to automation in the microbiology laboratory and offer insight into the reasons why we believe that we are on the cusp of a dramatic change that will sweep a wave of automation into clinical microbiology laboratories. We review the currently available specimen-processing instruments as well as the total laboratory automation solutions. Lastly, we outline the types of studies that will need to be performed to fully assess the benefits of automation in microbiology laboratories. PMID:23515547

  19. [Midwifery clinical practicum education].

    Science.gov (United States)

    Kao, Chien-Huei; Gau, Meei-Ling

    2013-06-01

    Midwifery is a practical facet of the health sciences that emphasizes professional competence-oriented teaching and learning. Cognitive and practical processes integrate and build midwifery student professional knowledge, attitudes, and skills. Clinical education is a teaching method and strategy used to prepare midwifery students for professional practice. Midwifery clinical teaching plans are designed using literature review, expert opinions, and student comments and determine total required hours and caseloads. Midwifery clinical teaching activities and methods promote self-reflection, childbirth education fundamentals, learning by role model observation, and learning role function through overseas observership programs. This paper discusses midwifery education dilemmas and coping methods in Taiwan.

  20. Determination of acrolein, ethanol, volatile acidity, and copper in different samples of sugarcane spirits Determinação de acroleína, etanol, acidez volátil e cobre em diferentes amostras de aguardentes de cana

    Directory of Open Access Journals (Sweden)

    José Masson

    2012-09-01

    Full Text Available Seventy-one samples of sugarcane spirits from small and average size stills produced in the northern and southern Minas Gerais (Brazil were analyzed for acrolein using HPLC (High Performance Liquid Chromatography. Ethanol and copper concentrations and volatile acidity were also determined according to methods established by the Ministry of Agriculture, Livestock and Supply (MAPA. A total of 9.85% of the samples tested showed levels of acrolein above the legal limits, while the copper concentrations of 21.00% of the samples and the volatile acidity of 8.85% of the samples were higher than the limits established by the Brazilian legislation. The concentration of acrolein varied from 0 to 21.97 mg.100 mL-1 of ethanol. However, no significant difference at 5% of significance was observed between the samples produced in the northern and southern Minas Gerais. The method used for determination of acrolein in sugarcane spirits involved the formation of a derivative with 2,4-dinitrophenylhydrazine (2,4-DNPH and subsequent analysis by HPLC.As setenta e uma amostras de aguardentes de cana coletadas em alambiques de pequeno e médio porte, provenientes das regiões norte e sul de Minas Gerais, foram avaliadas por CLAE (Cromatografia Líquida de Alta Eficiência quanto ao teor de acroleína. Avaliaram-se também as concentrações de etanol, acidez volátil e cobre, utilizando-se as metodologias estabelecidas pelo Ministério da Agricultura, Pecuária e Abastecimento (MAPA. Do total de amostras, 9,85% apresentaram níveis de acroleína acima do limite legal, 21,00% apresentaram teores de cobre e 8,85% de acidez volátil acima dos limites estabelecidos pela legislação brasileira. Os teores de acroleína variaram de 0 a 21,97 mg.100 mL-1 de etanol. Entretanto, não ocorreu diferença significativa no nível de 5% de significância entre as amostras do norte e as do sul de Minas Gerais. O método aplicado para a determinação de acroleína em aguardente de

  1. Clinical use of a portable dual microscope system for smartphone (Conference Presentation)

    Science.gov (United States)

    Kurachi, Cristina; Brognara, Gabriel; Gómez-García, Pablo A.; Carbinatto, Fernanda; Silva, Eduardo V.; Lombardi, Wellington; Inada, Natália M.; Bagnato, Vanderlei S.

    2016-03-01

    Cervical cancer is still one of the most relevant women cancer types, since the 5-year survival rate is of only around 68%. Prevention and early diagnosis are the best strategies to improve cervical cancer prognosis. Conventional diagnosis procedure in Gynecology is mainly based on the macroscopic clinical evaluation, Pap smear cytology, and biopsy, if needed. A portable microscope with dual configuration and its use for diagnosis in Gynecology is investigated. The microscope has interchangeable parts that allow its use for cytopathology smear samples or in situ endoscopic tissue interrogation, both using acriflavine as a nuclei marker. Patients of the Women Ambulatory of the School of Medicine (UNIARA, Araraquara, Brazil) were interrogated during the colposcopy examination. The cervix was initially cleaned using an acetic acid solution, and a 0.05% (wt/vol) acriflavine in saline solution was topically applied at the tissue surface using a cotton swab. Microendoscopy images were taken from clinically normal cervix mucosa and from detected lesions. An image processing is performed to evaluate the cell nuclei morphology and the cytoplasm/nuclei ratio. The Pap smear results and the histology analyses are taken as gold standard for the diagnosis. Preliminary results in 5 patients demonstrated the potential use of our microscope at the clinical setting.

  2. Clinical Case Registries (CCR)

    Data.gov (United States)

    Department of Veterans Affairs — The Clinical Case Registries (CCR) replaced the former Immunology Case Registry and the Hepatitis C Case Registry with local and national databases. The CCR:HIV and...

  3. Hepatitis C: Clinical Trials

    Science.gov (United States)

    ... and Public Home » Hepatitis C » Treatment Decisions Viral Hepatitis Menu Menu Viral Hepatitis Viral Hepatitis Home For ... can I find out about participating in a hepatitis C clinical trial? Many trials are being conducted ...

  4. Clinical leadership project.

    Science.gov (United States)

    Kling, Vera G

    2010-11-01

    Nurse educators seek innovative strategies to maximize student learning in the classroom and clinical settings. Students enrolled in a nursing leadership and management course often find they spend more clinical time observing leaders than practicing the necessary skills to lead others in the provision of nursing care. In addition, opportunities to explore the nurse educator role often do not exist in baccalaureate nursing education, despite the shortage of nurse educators. An experience was developed in a baccalaureate nursing program to give senior students, under supervision of faculty, the opportunity to lead and evaluate lower-level students providing patient care in the clinical setting and to experience the role of nursing faculty. Feedback from senior students was positive, and students noted increased proficiency in leadership ability and critical thinking. Student interest in the nurse educator role was also enhanced. Program expansion and evaluation with faculty, clinical staff, and patients are planned.

  5. Fidelity in clinical simulation

    DEFF Research Database (Denmark)

    Jensen, Sanne; Nøhr, Christian; Rasmussen, Stine Loft

    2013-01-01

    Clinical simulation may be used to identify user needs for context sensitive functionalities in e-Health. The objective with this paper is to describe how user requirements and use cases in a large EHR-platform procurement may be validated by clinical simulation using a very low-fidelity prototype...... without any existing test data. Instead of using test scenarios and use cases, the healthcare professionals who are participating in the clinical simulation are generating both scenario and patient data themselves. We found that this approach allows for an imaginative discussion, not restricted by known...... functionalities and limitations, of the ideal EHR-platform. Subsequently, we discuss benefits and challenges of using an extremely low fidelity environment and discuss the degree of fidelity necessary for conducting clinical simulation....

  6. Clinical specular microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hirst, L.W.; Laing, R.A.

    1987-01-01

    This book provides the general ophthalmologist with a guide to the clinical applications of specular microscopy. Important material is included on laser injury, cataract surgery, corneal transplants, glaucoma, uveitis, and trauma.

  7. Celiac disease: clinical observations

    Directory of Open Access Journals (Sweden)

    Yu. A. Emel’yanova

    2016-01-01

    Full Text Available Presented clinical cases of patients with a diagnosis of gluten enteropathy in treatment in the department of gastroenterology Regional Clinical Hospital. The case is of interest to doctors of different specialties for the differential diagnosis of anemia and malabsorption syndrome, demonstrate both the classic version, and atypical forms of the disease course. Diagnosis of celiac disease is based on three key positions: clinical findings, histology and serological markers. The clinical picture of celiac disease is characterized by pronounced polymorphism, by going beyond the a gastroenterological pathology. For screening of gluten sensitive celiac typically used an antibody to tissue transglutaminase. Morphological research of the mucous membrane of the small intestine is the determining criterion in the diagnosis of celiac disease. The use of specific gluten-free diet leads to the positive dynamics of the disease and improve the quality of life of patients.

  8. Health Clinic Cost Reports

    Data.gov (United States)

    U.S. Department of Health & Human Services — Healthcare Cost Report Information System (HCRIS) Dataset - Independent Rural Health Clinic and Freestanding Federally Qualified Health Center (HCLINIC).This data...

  9. Understanding Clinical Alarm Safety.

    Science.gov (United States)

    Lukasewicz, Carol L; Mattox, Elizabeth Andersson

    2015-08-01

    Patient safety organizations and health care accreditation agencies recognize the significance of clinical alarm hazards. The Association for the Advancement of Medical Instrumentation, a nonprofit organization focused on development and use of safe and effective medical equipment, identifies alarm management as a major issue for health care organizations. ECRI Institute, a nonprofit organization that researches approaches for improving patient safety and quality of care, identifies alarm hazards as the most significant of the "Top Ten Health Technology Hazards" for 2014. A new Joint Commission National Patient Safety Goal focusing on clinical alarm safety contains new requirements for accredited hospitals to be fully implemented by 2016. Through a fictional unfolding case study, this article reviews selected contributing factors to clinical alarm hazards present in inpatient, high-acuity settings. Understanding these factors improves contributions by nurses to clinical alarm safety practice.

  10. NIH Pediatric Rheumatology Clinic

    Science.gov (United States)

    ... to diagnose and treat children with arthritis, periodic fever syndromes, and rheumatic diseases. This clinic will also help doctors and ... are juvenile arthritis including spondyloarthritis, lupus, and periodic ... how juvenile rheumatic diseases affect them and what treatments work best. ...

  11. Alagille syndrome: clinical perspectives

    Directory of Open Access Journals (Sweden)

    Saleh M

    2016-06-01

    Full Text Available Maha Saleh,1 Binita M Kamath,2 David Chitayat1,3 1Division of Clinical and Metabolic Genetics, 2Division of Gastroenterology, Hepatology and Nutrition, Department of Pediatrics, The Hospital for Sick Children, 3Department of Obstetrics and Gynecology, Prenatal Diagnosis and Medical Genetics Program, Mount Sinai Hospital, University of Toronto, Toronto, ON, Canada Abstract: Alagille syndrome is an autosomal dominant, complex multisystem disorder characterized by the presence of three out of five major clinical criteria: cholestasis with bile duct paucity on liver biopsy, congenital cardiac defects (with particular involvement of the pulmonary arteries, posterior embryotoxon in the eye, characteristic facial features, and butterfly vertebrae. Renal and vascular abnormalities can also occur. Inter- and intrafamilial variabilities in the clinical manifestations are common. We reviewed the clinical features and management as well as the molecular basis of Alagille syndrome. Keywords: Alagille syndrome, ALGS, genetics, liver 

  12. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... a disease. A clinical trial may compare experimental products or tests to those already available or may ... Institutes of Health | U.S. Department of Health & Human Services Customer Support | Accessibility | Copyright | Privacy | Viewers and Players

  13. OARSI Clinical Trials Recommendations

    DEFF Research Database (Denmark)

    Kraus, V B; Blanco, F J; Englund, M

    2015-01-01

    The objective of this work was to describe requirements for inclusion of soluble biomarkers in osteoarthritis (OA) clinical trials and progress toward OA-related biomarker qualification. The Guidelines for Biomarkers Working Group, representing experts in the field of OA biomarker research from...... of reasons but in particular, to determine whether biomarkers are useful in identifying those individuals most likely to receive clinically important benefits from an intervention; and to determine whether biomarkers are useful for identifying individuals at earlier stages of OA in order to institute...... both academia and industry, convened to discuss issues related to soluble biomarkers and to make recommendations for their use in OA clinical trials based on current knowledge and anticipated benefits. This document summarizes current guidance on use of biomarkers in OA clinical trials...

  14. Participating in Clinical Trials

    Medline Plus

    Full Text Available ... experimental drug, therapy, medical device, lifestyle change, or test will help treat, find, or prevent a disease. A clinical trial may compare experimental products or tests to those already available or may compare existing ...

  15. ClinicalTrials.gov

    Data.gov (United States)

    U.S. Department of Health & Human Services — Provides patients, family members, health care professionals, and members of the public easy access to information on clinical trials for a wide range of diseases...

  16. Falsificationism and clinical trials.

    Science.gov (United States)

    Senn, S J

    1991-11-01

    The relevance of the philosophy of Sir Karl Popper to the planning, conduct and analysis of clinical trials is examined. It is shown that blinding and randomization can only be regarded as valuable for the purpose of refuting universal hypotheses. The purpose of inclusion criteria is also examined. It is concluded that a misplaced belief in induction is responsible for many false notions regarding clinical trials.

  17. Clinical studies involving probiotics

    OpenAIRE

    Degnan, Fred H

    2012-01-01

    Researchers from a diverse array of scientific disciplines have focused and continue to focus on opportunities and areas for responsible clinical research involving the possible beneficial health effects of “probiotics.” Investigators and researchers should be aware that not all clinical research involving probiotics reasonably falls within the requirements of the “investigational new drug” (IND) rubric administered and enforced by the US Food and Drug Administration. In determining whether a...

  18. The clinical nanomedicine handbook

    CERN Document Server

    Brenner, Sara

    2013-01-01

    Designed to foster a stronger awareness and exploration of the subject by practicing clinicians, medical researchers and scientists, The Clinical Nanomedicine Handbook discusses the integration of nanotechnology, biology, and medicine from a clinical point of view. The book highlights relevant research and applications by specialty; it examines nanotechnology in depth, and the potential to solve medical problems. It also increases literacy in nanotechnology, and allows for more effective communication and collaboration between disciplines. Details worldwide developments in nanomedicine Provide

  19. Clinical Nursing Records Study

    Science.gov (United States)

    1991-08-01

    for Sam Houston, Texas MAJ Joanne Burton , AN, Clinical Head Nurse, Psychiatry MAJ Shelby Christian, AN, Clinical Head Nurse, OB/GYN MAJ Melissa Opio...Specify Level) Parenting, Potential Alteration In Decubitus Ulcer Self-Care Deficit, Total (Specify Level) Social Isolation Fluid Volume Deficit. Potential...METABOLIC PATTERN Self-Care Dieficit. Total (Specify Level) SiX alizaticni Alterations ifl Decubitus ulcer S-If-Batingrla.v~qene Oeticit 601?Cif Levet

  20. 线粒体DNA缺失HepG2细胞系的建立、鉴定及放射生物学特性%Observation of radiobiological characteristics in a HepG2 cell line with mitochondrial DNA deletion

    Institute of Scientific and Technical Information of China (English)

    孙恒文; 潘燚; 曾子君; 方良毅; 张红丹; 谢松喜; 李伟雄; 许家彬

    2015-01-01

    目的:为研究人肝癌细胞系HepG2线粒体DNA(mtDNA)缺失后的放射生物学特性,建立并鉴定mtDNA缺失HepG2(ρ0HepG2)细胞系。测定辐射干预下mtDNA缺失(Rho0)肝癌细胞的凋亡情况、侵袭能力以及辐射敏感性的变化。方法在含有溴化乙锭(EB)、丙酮酸、尿嘧啶的特殊培养基中培养HepG2细胞,经30次传代后,有限稀释法筛选完全去除mtDNA的克隆。去除丙酮酸及尿嘧啶后,观察细胞的存活情况。PCR法鉴定mtDNA的缺失。用6MvX射线梯度剂量照射HepG2细胞和ρ0HepG2细胞,平板克隆法绘制生长曲线,线性二次方程拟合生存曲线,计算α/β。2Gy剂量辐射细胞,24 h后用Hochest33342细胞核染色,比较HepG2细胞与ρ0HepG2凋亡率的差异。用Transwell法测定两种不同细胞的侵袭能力。结果在含EB特殊培养环境下,HepG2细胞可持续生长传代至30代,去除丙酮酸和尿嘧啶后,细胞短时间内大量死亡。经PCR法证实mtDNA完全缺失。ρ0HepG2细胞α/β显著低于正常HepG2细胞,辐射抵抗能力增强。辐射干预后ρ0HepG2的凋亡比例显著减少。ρ0HepG2穿膜细胞数显著增多。结论在EB长期诱导下,HepG2肝癌细胞可被成功诱导为mtDNA缺失细胞。ρ0HepG2细胞的辐射抵抗性显著增强,抗凋亡能力及侵袭能力均提高。%Objective To study the radiobiological characteristics of a HepG2 cell line with mitochondrial DNA (mtDNA) deletion. Methods HepG2 cells were cultured in a medium containing ethidium bromide, acetylformic acid and uracil. The HepG2 cell line with mtDNA deletion (ρ0HepG2 cells) were acquired after 30 subcultures by limited dilution cloning. The cell survival was then observed in the absence of acetylformic acid and uracil, and the total mtDNA deletion in the cells was confirmed by PCR. The radiosensitivity of HepG2 andρ0HepG2 cells was evaluated by exposure to gradient doses of 6 MV X ray irradiation. The

  1. Clinical research: regulatory issues.

    Science.gov (United States)

    Wermeling, D P

    1999-02-01

    The regulatory issues faced by institutions performing clinical research are described. Many institutions do not have on staff an expert who understands the regulatory issues involved in managing investigational new drug research and who knows the institution's obligations under the federal rules. Because pharmacists understand the FDA regulations that apply to the management of drugs in clinical research, institutions are asking pharmacists to expand their role and manage clinical research offices. Many authorities govern various aspects of investigational drug research. FDA has published regulations for good clinical practice (GCP), and the International Conference on Harmonisation is developing an international standard for the proper management of clinical trials. The guidelines published by the Joint Commission on Accreditation of Healthcare Organizations aim to protect patients who are in the institution to receive health care and also participate in clinical trials. The Social Security Administration Acts specifically state that only items and services that are reasonable and necessary for the diagnosis and treatment of injury or disease can be billed to the government; research-related billings are excluded from coverage. Proper management of drug research is crucial to the success of a research program that is integrated with patient care.

  2. Fundamentals of clinical trials

    CERN Document Server

    Friedman, Lawrence M; DeMets, David L; Reboussin, David M; Granger, Christopher B

    2015-01-01

    This is the fifth edition of a very successful textbook on clinical trials methodology, written by recognized leaders who have long and extensive experience in all areas of clinical trials. The three authors of the first four editions have been joined by two others who add great expertise.  Most chapters have been revised considerably from the fourth edition.  A chapter on regulatory issues has been included and the chapter on data monitoring has been split into two and expanded.  Many contemporary clinical trial examples have been added.  There is much new material on adverse events, adherence, issues in analysis, electronic data, data sharing, and international trials.  This book is intended for the clinical researcher who is interested in designing a clinical trial and developing a protocol. It is also of value to researchers and practitioners who must critically evaluate the literature of published clinical trials and assess the merits of each trial and the implications for the care and treatment of ...

  3. Children and Clinical Studies: Why Clinical Studies Are Important

    Medline Plus

    Full Text Available ... about Children and Clinical Studies Importance of Children in Clinical Studies Children have often had to accept ... treatments based on what is known to work in adults. To improve clinical care of children, more ...

  4. Structured assessments of clinical competence.

    Science.gov (United States)

    Boursicot, Katharine A M

    2010-06-01

    Clinical teachers are often involved in assessing clinical competence in the workplace, in universities and colleges. Assessments commonly used to formally assess clinical competence include long and short cases and the objective structured clinical examination which, if well designed, is a fair and reliable method of assessing clinical competence.

  5. Aplicación de las técnicas de espacio de cabeza a la extracción de los compuestos orgánicos volátiles de la oleorresina de pimentón

    Directory of Open Access Journals (Sweden)

    Guadayol, J. M.

    1997-02-01

    Full Text Available Static and dynamic headspace techniques have been applied to the extraction and concentration of volatile organic compounds (VOCs from paprika oleoresin. In dynamic headspace, both purge and trap and sweeping techniques have been used. In order to show the influence of temperature on the extraction techniques, three differents temperatures have been applied to each technique. The separation and identification of the extracted VOCs has been carried out through HRGC/MS. The extraction techniques are simple and easily reproducible.

    Se han aplicado las técnicas de espacio de cabeza estático y dinámico para la extracción y concentración de los compuestos orgánicos volátiles de la oleorresina de pimentón. En espacio de cabeza dinámico se han utilizado las variantes de arrastre con borboteo y espacio de cabeza dinámico propiamente dicho. Con el fin de estudiar la influencia de la temperatura en ambas técnicas de extracción, se han realizado pruebas a tres temperaturas diferentes en cada una de ellas, estudiando la influencia de la misma en el proceso de aislamiento de los CVOs. La separación e identificación de los CVOs extraídos se ha llevado a cabo mediante HRGC/MS. Todas las técnicas presentadas son de aplicación simple y reproducibles con facilidad.

  6. Analysis of crystallographic slip and grain boundary sliding in a Ti–45Al–2Nb–2Mn (at%)–0.8 vol%TiB{sub 2} alloy by high temperature in situ mechanical testing

    Energy Technology Data Exchange (ETDEWEB)

    Muñoz-Moreno, R. [IMDEA Materials Institute, C/Eric Kandel 2, 28906 Getafe, Madrid (Spain); Department of Materials Science and Engineering, Universidad Carlos III de Madrid, Avda. Universidad 30, 28911 Leganés (Spain); Ruiz-Navas, E.M. [Department of Materials Science and Engineering, Universidad Carlos III de Madrid, Avda. Universidad 30, 28911 Leganés (Spain); Boehlert, C.J. [IMDEA Materials Institute, C/Eric Kandel 2, 28906 Getafe, Madrid (Spain); Department of Chemical Engineering and Materials Science, Michigan State University, 2527 Engineering Building, East Lansing, MI 48824 (United States); Llorca, J. [IMDEA Materials Institute, C/Eric Kandel 2, 28906 Getafe, Madrid (Spain); Department of Materials Science, Polytechnic University of Madrid, 28040 Madrid (Spain); Torralba, J.M. [IMDEA Materials Institute, C/Eric Kandel 2, 28906 Getafe, Madrid (Spain); Department of Materials Science and Engineering, Universidad Carlos III de Madrid, Avda. Universidad 30, 28911 Leganés (Spain); Pérez-Prado, M.T., E-mail: teresa.perez.prado@imdea.org [IMDEA Materials Institute, C/Eric Kandel 2, 28906 Getafe, Madrid (Spain)

    2014-06-01

    This work aims to contribute to a further understanding of the fundamentals of crystallographic slip and grain boundary sliding in the γ-TiAl Ti–45Al–2Nb–2Mn (at%)–0.8 vol%TiB{sub 2} intermetallic alloy, by means of in situ high-temperature tensile testing combined with electron backscatter diffraction (EBSD). Several microstructures, containing different fractions and sizes of lamellar colonies and equiaxed γ-grains, were fabricated by either centrifugal casting or powder metallurgy, followed by heat treatment at 1300 °C and furnace cooling. in situ tensile and tensile-creep experiments were performed in a scanning electron microscope (SEM) at temperatures ranging from 580 °C to 700 °C. EBSD was carried out in selected regions before and after straining. Our results suggest that, during constant strain rate tests, true twin γ/γ interfaces are the weakest barriers to dislocations and, thus, that the relevant length scale might be influenced by the distance between non-true twin boundaries. Under creep conditions both grain/colony boundary sliding (G/CBS) and crystallographic slip are observed to contribute to deformation. The incidence of boundary sliding is particularly high in γ grains of duplex microstructures. The slip activity during creep deformation in different microstructures was evaluated by trace analysis. Special emphasis was placed in distinguishing the compliance of different slip events with the Schmid law with respect to the applied stress.

  7. 浅谈《世界古代史(下)》课程的教学%On the Teaching of the Ancient World History(vol.2) Course

    Institute of Scientific and Technical Information of China (English)

    汪增相

    2013-01-01

      The Ancient World History (vol.2 ) is one of the compulsory Professional foundation courses for the history students in college,and an important part of the curriculum system of the General History of World. In order to do well in the teaching of this course,the teacher must to do from three aspects as follows : first, arrange the teaching content in the height of the general history; second, select the teaching methods Focusing on students;third, optimize the teaching means using multimedia technology.%  《世界古代史(下)》是大学历史专业学生必修的专业基础课程之一,是《世界通史》大课程的一个重要组成部分。要搞好这门课程的教学,教师需要做到:第一,要能够从通史的高度统筹教学内容;第二,要能够以学生为中心选择教学方法;第三,要能够用多媒体技术优化教学手段。

  8. Recuperación de ácidos grasos volátiles por electrodiálisis de un licor de fermentación anaerobia de desechos orgánicos simulado

    Directory of Open Access Journals (Sweden)

    Aymer Maturana

    2004-01-01

    Full Text Available Se diseñó, construyó y operó una unidad de electrodiálisis para estudiar experimentalmente la recuperación como ácido acético del acetato producido durante la digestión anaerobia de desechos orgánicos, usando soluciones acuosas de acetato de sodio a diferentes concentraciones (5 g/l, 15 g/l y 30 g/l para simular el licor de fermentación anaerobia. La electrodiálisis se llevó a cabo aplicando 8 diferentes voltajes a la unidad y monitoreando periódicamente el comportamiento de las variables principales del proceso. La tasa máxima de producción de ácido acético lograda fue de 1674 mg/l y se encontró que esta fue proporcional al voltaje aplicado, caudal de licor de fermentación alimentado a la unidad y a la densidad de corriente utilizada. El ácido acético se recuperó en agua destilada y adicionalmente en una solución acuosa de etanol. La electrodiálisis resultó ser una alternativa técnicamente viable en principio, para la producción de ácidos grasos volátiles, pues los resultados obtenidos demuestran que es posible hacerlo con relativa facilidad.

  9. Clinical impact of {sup 99m}Tc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with {sup 90}Y-loaded microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Garin, Etienne [Cancer Institute Eugene Marquis, Department of Nuclear Medicine, Rennes (France); University of Rennes 1, Rennes (France); INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Rolland, Yan [Cancer Institute Eugene Marquis, Department of Medical Imaging, Rennes (France); Laffont, Sophie [University of Rennes 1, Rennes (France); Edeline, Julien [University of Rennes 1, Rennes (France); INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Cancer Institute Eugene Marquis, Department of Medical Oncology, Rennes (France)

    2016-03-15

    Radioembolization with {sup 90}Y-loaded microspheres is increasingly used in the treatment of primary and secondary liver cancer. Technetium-99 m macroaggregated albumin (MAA) scintigraphy is used as a surrogate of microsphere distribution to assess lung or digestive shunting prior to therapy, based on tumoral targeting and dosimetry. To date, this has been the sole pre-therapeutic tool available for such evaluation. Several dosimetric approaches have been described using both glass and resin microspheres in hepatocellular carcinoma (HCC) and liver metastasis. Given that each product offers different specific activities and numbers of spheres injected, their radiobiological properties are believed to lightly differ. This paper summarizes and discusses the available studies focused on MAA-based dosimetry, particularly concentrating on potential confounding factors like clinical context, tumor size, cirrhosis, previous or concomitant therapy, and product used. In terms of the impact of tumoral dose in HCC, the results were concordant and a response relationship and tumoral threshold dose was clearly identified, especially in studies using glass microspheres. Tumoral dose has also been found to influence survival. The concept of treatment intensification has recently been introduced, yet despite several studies publishing interesting findings on the tumor dose-metastasis relationship, no consensus has been reached, and further clarification is thus required. Nor has the maximal tolerated dose to the liver been well documented, requiring more accurate evaluation. Lung dose was well described, despite recently identified factors influencing its evaluation, requiring further assessment. MAA SPECT/CT dosimetry is accurate in HCC and can now be used in order to achieve a fully customized approach, including treatment intensification. Yet further studies are warranted for the metastasis setting and evaluating the maximal tolerated liver dose. (orig.)

  10. Computerizing clinical practice guidelines

    DEFF Research Database (Denmark)

    Lyng, Karen Marie

    It is well described that hospitals have problems with sustaining high quality of care and expedient introduction of new medical knowledge. Clinical practice guidelines (CPGs) have been promoted as a remedy to deal with these problems. It is, however, also well described that application and comp......It is well described that hospitals have problems with sustaining high quality of care and expedient introduction of new medical knowledge. Clinical practice guidelines (CPGs) have been promoted as a remedy to deal with these problems. It is, however, also well described that application...... and compliance with CPGs in most areas of clinical practice are deficient. Computerization of CPGs has been brought forward as a method to disseminate and to support application of CPGs. Until now, CPG-computerization has focused on development of formal expressions of CPGs. The developed systems have, however......, not gained any extensive application in clinical practice. The basic assumption in this thesis is that the scanty penetration is due to an inappropriate design process when designing computerized CPGs for clinical work practice. This thesis examines the application of guidance within areas where CPG...

  11. Danish clinical databases: An overview

    DEFF Research Database (Denmark)

    Green, Anders

    2011-01-01

    Clinical databases contain data related to diagnostic procedures, treatments and outcomes. In 2001, a scheme was introduced for the approval, supervision and support to clinical databases in Denmark....

  12. Transgressive first clinical experiences

    DEFF Research Database (Denmark)

    Jensen, Carsten Juul; Jeppesen, Lise Kofoed; Drachmann, Merete

    2014-01-01

    This Study seeks to comprehend learning experiences of nursing students during their first clinical in-service placement. This Paper is part of a longitudinal development project interviewing the Student Nurse after each one of the five clinical in-service placements and then one year after...... to advanced beginner, and adjusting to the workplace community. The conclusion is that the learning of nursing students during their first clinical in-service placement appears informal and not founded on evident best practice....... graduation as a Nurse. The Study has a qualitative methodology, inspired by Michael Eraut’s thoughts on learning in the workplace. When the workplace perspective is applied, learning seems to be concentrated on actual situations which the Learner is in, in contrast to employing constructed concepts...

  13. Pediatric anthrax clinical management.

    Science.gov (United States)

    Bradley, John S; Peacock, Georgina; Krug, Steven E; Bower, William A; Cohn, Amanda C; Meaney-Delman, Dana; Pavia, Andrew T

    2014-05-01

    Anthrax is a zoonotic disease caused by Bacillus anthracis, which has multiple routes of infection in humans, manifesting in different initial presentations of disease. Because B anthracis has the potential to be used as a biological weapon and can rapidly progress to systemic anthrax with high mortality in those who are exposed and untreated, clinical guidance that can be quickly implemented must be in place before any intentional release of the agent. This document provides clinical guidance for the prophylaxis and treatment of neonates, infants, children, adolescents, and young adults up to the age of 21 (referred to as "children") in the event of a deliberate B anthracis release and offers guidance in areas where the unique characteristics of children dictate a different clinical recommendation from adults.

  14. [Clinical variants of acne].

    Science.gov (United States)

    Jansen, T; Grabbe, S; Plewig, G

    2005-11-01

    Acne is a very common dermatosis with characteristic clinical features. It is a polymorphic disease. The clinical expression ranges from non-inflammatory closed and open comedones to inflammatory papules, pustules, and nodules. Most patients have a mixture of non-inflammatory and inflammatory lesions, although some have predominantly one or the other. Acne varies in severity from a very distressing, socially disabling disorder to a state that has been regarded as physiological by some authors. The most severe forms of acne are acne fulminans and acne inversa. Although acne may occur in all age groups, it is most prevalent during adolescence. It is not known why acne subsides in most patients but persists into adulthood in some. Certain medications may be associated with provocation, perpetuation, or exacerbation of pre-existing acne or with acneiform eruptions. Acne-like disorders include rosacea, pseudofolliculitis barbae, and other conditions that share clinical features with acne.

  15. Computerizing clinical practice guidelines

    DEFF Research Database (Denmark)

    Lyng, Karen Marie

    . The analysis focuses on the emergence of general clinical work practice demands on guidance • An analysis of guidance demands from clinical work practice and business strategy, focusing on implications for the design of computerised CPGs. In my research, I have applied observation studies, interviews...... is comprised by fieldwork in three oncology departments and a case study of advanced life support. Although close to all patients within oncology are treated according to a CPG, I found limited application of physical CPGs and web-based CPG portals. However, I found comprehensive application of activity...... feasible • Designed in a way that provides room for local adaptations of guidance • Designed with focus on specific business strategic aims Further, based on my findings, I will suggest that design of computerized CPGs should be based on: 1) scrutinization of the clinical work practice, 2) articulation...

  16. OARSI Clinical Trials Recommendations

    DEFF Research Database (Denmark)

    McAlindon, T. E.; Driban, J. B.; Henrotin, Y.;

    2015-01-01

    The goal of this document is to update the original OARSI recommendations specifically for the design, conduct, and reporting of clinical trials that target symptom or structure modification among individuals with knee osteoarthritis (OA). To develop recommendations for the design, conduct...... and index knee, describing interventions, patient-reported and physical performance measures, structural outcome measures, biochemical biomarkers, and reporting recommendations. In summary, the working group identified 25 recommendations that represent the current best practices regarding clinical trials...... that target symptom or structure modification among individuals with knee OA. These updated recommendations incorporate novel technologies (e.g., magnetic resonance imaging (MRI)) and strategies to address the heterogeneity of knee OA....

  17. [Antidotes in clinical toxicology].

    Science.gov (United States)

    Hruby, K

    2013-09-01

    This overview describes antidotes, and their clinical pharmacology, that have an established significance in the currently practiced clinical toxicology because of their proven effectiveness in the treatment of serious poisonings. For the proper, efficient, and targeted use of an antidote, pharmacological knowledge is required, which is a central subject of this article. Current data from the literature are used as reference along with the accumulated experiences about possible adverse effects in order to include them in therapeutic considerations. The dosage of antidotes is the subject of several other review articles and is therefore not included in this synopsis.

  18. Clinical Evaluation of Tinnitus.

    Science.gov (United States)

    Hertzano, Ronna; Teplitzky, Taylor B; Eisenman, David J

    2016-05-01

    The clinical evaluation of patients with tinnitus differs based on whether the tinnitus is subjective or objective. Subjective tinnitus is usually associated with a hearing loss, and therefore, the clinical evaluation is focused on an otologic and audiologic evaluation with adjunct imaging/tests as necessary. Objective tinnitus is divided into perception of an abnormal somatosound or abnormal perception of a normal somatosound. The distinction between these categories is usually possible based on a history, physical examination, and audiogram, leading to directed imaging to identify the underlying abnormality.

  19. Toward transparent clinical policies.

    Science.gov (United States)

    Shiffman, Richard N; Marcuse, Edgar K; Moyer, Virginia A; Neuspiel, Daniel R; Hodgson, Elizabeth Susan; Glade, Gordon; Harbaugh, Norman; Miller, Marlene R; Sevilla, Xavier; Simpson, Lisa; Takata, Glenn

    2008-03-01

    Clinical policies of professional societies such as the American Academy of Pediatrics are valued highly, not only by clinicians who provide direct health care to children but also by many others who rely on the professional expertise of these organizations, including parents, employers, insurers, and legislators. The utility of a policy depends, in large part, on the degree to which its purpose and basis are clear to policy users, an attribute known as the policy's transparency. This statement describes the critical importance and special value of transparency in clinical policies, guidelines, and recommendations; helps identify obstacles to achieving transparency; and suggests several approaches to overcome these obstacles.

  20. Spreadsheets in Clinical Medicine

    CERN Document Server

    Croll, Grenville J

    2006-01-01

    There is overwhelming evidence that the continued and widespread use of untested spreadsheets in business gives rise to regular, significant and unexpected financial losses. Whilst this is worrying, it is perhaps a relatively minor concern compared with the risks arising from the use of poorly constructed and/or untested spreadsheets in medicine, a practice that is already occurring. This article is intended as a warning that the use of poorly constructed and/or untested spreadsheets in clinical medicine cannot be tolerated. It supports this warning by reporting on potentially serious weaknesses found while testing a limited number of publicly available clinical spreadsheets.

  1. Clinical reasoning of nursing students on clinical placement: Clinical educators' perceptions.

    Science.gov (United States)

    Hunter, Sharyn; Arthur, Carol

    2016-05-01

    Graduate nurses may have knowledge and adequate clinical psychomotor skills however they have been identified as lacking the clinical reasoning skills to deliver safe, effective care suggesting contemporary educational approaches do not always facilitate the development of nursing students' clinical reasoning. While nursing literature explicates the concept of clinical reasoning and develops models that demonstrate clinical reasoning, there is very little published about nursing students and clinical reasoning during clinical placements. Semi-structured interviews were conducted with ten clinical educators to gain an understanding of how they recognised, developed and appraised nursing students' clinical reasoning while on clinical placement. This study found variability in the clinical educators' conceptualisation, recognition, and facilitation of students' clinical reasoning. Although most of the clinical educators conceptualised clinical reasoning as a process those who did not demonstrated the greatest variability in the recognition and facilitation of students' clinical reasoning. The clinical educators in this study also described being unable to adequately appraise a student's clinical reasoning during clinical placement with the use of the current performance assessment tool.

  2. CME ON CLINICAL RESEARCH

    Directory of Open Access Journals (Sweden)

    Suneel. I. Majagi

    2012-06-01

    Full Text Available Safety and efficacy are the two major concerns for any drug therapy. Globally clinical research plays an inevitable role in bringing a new molecule into the market after its synthesis by the pharmaceutical industries. Availability of large patient population, highly educated and skilled manpower, wide spectrum of diseases and favorable economic environment imply India’s potential as a global hub for clinical research. Pharmaceutical companies and Clinical Research Organization (CROs will require many trained personnel to carry out the clinical research. Keeping in mind these facts a CME with the theme of “Clinical research” had been jointly organized by the Dept of pharmacology, K.L.E University’s J.N.M.C, Belgaum and Indian Pharmacological Society (I.P.S, Belgaum branch on 20th February 2010. In the first scientific session, Dr.P.A.Patil (JNMC spoke on “Preclinical studies”. In vitro and in vivo experiments of various doses of ‘study drug’ can obtain preliminary efficacy, toxicity and pharmacokinetic information suggesting the scientific merit for further development as an investigational new drug (IND. Local or systemic toxicity studies can be conducted (ex: urine analysis, blood biochemical assay, gross and microscopic pathology etc. Dr. B.J. Mahendra Kumar (KLE University’s College of pharmacy talked on “Role of Drug Controller General of India (DCGI in Clinical Trials”. He explained about Drug and cosmetic acts/rules, requirements/guidelines for permission to import and/or to manufacture new drugs or to undertake clinical trials i.e. Schedule Y and its appendices. Dr.N.M.Patil (JNMC elaborated about “Ethical issues in clinical trials”. Ethics is required to: avoid exploitation of the subjects (maintain safety and wellbeing, protect vulnerable groups, children, disabled, elderly etc. Independent Ethics Committees (IEC and Institutional Review Boards (IRB are concerned with medical ethics. IECs review, regulate

  3. The Effect of Triage on Patient Flow in an Outpatient Clinic.

    Science.gov (United States)

    1979-12-01

    Emergency Department." Canadian Medical Association Journal Vol. 109 No. 5 (September 1, 1973): 373-376. 3. Alpert , Joel J. "Broken Appointments... Larry E. and Riskin, Wayne G. "Algorithm-Directed Triage in an Emergency Department." Journal of the American College of Physicians Vol. 5 No. 11

  4. Clinical guidelines, clinical pathways and protocols of care

    OpenAIRE

    Angélica Román

    2012-01-01

    The article points out that the importance of standardization of clinical practices has been established in clinical management, which helps solve the problems of variability by developing documents based on the available scientific evidence. The article claims that healthcare culture has increasingly recognized the importance of standardization of clinical practices and provides a conceptual difference between clinical practice guidelines, protocols and algorithms. Clinical pathways and clin...

  5. Prolactinomas : clinical studies

    NARCIS (Netherlands)

    Kars, Marleen

    2008-01-01

    Prolactinoma are treated with dopamine agonists, which are effective in reducing prolactin and tumor size. Studies reporting clinical and radiological outcome are scarce. The study described in chapter 2, assesses long-term outcome in patients treated with dopamine agonists for macroprolactinoma. An

  6. Clinical Mastery of Hypnosis.

    Science.gov (United States)

    Horevitz, Richard P.

    Hypnosis is an increasingly popular clinical intervention. The number of training courses in hypnosis is growing each year. Research on hypnosis training appears to show that limited exposure to training, as is typical in the common 3 to 5 day format of mass training, produces limited results. Only when training is extended over time do the…

  7. Assessment of Clinical Competence.

    Science.gov (United States)

    Newble, David I.

    1979-01-01

    Reviews current approaches to the examination of medical students' clinical competence, mentioning differences in approaches adopted in Australia, Great Britain, and North America. Test methods used in examination are discussed critically and their separate strengths and weaknesses are highlighted. Newer approaches involving multiple methods and…

  8. Validating clinical competence.

    Science.gov (United States)

    Chappell, Kathy; Koithan, Mary

    2012-07-01

    Professional registered nurses must be competent to provide care in today's fast-paced, highly technical clinical environment. Competency programs designed to teach and evaluate essential knowledge, skills, and abilities of registered nurses are one method organizations may use to demonstrate nursing proficiency.

  9. Evaluation of Clinical Competence.

    Science.gov (United States)

    Newble, David I.

    In Australia the usual evaluation of whether a student will perform adequately as a doctor is a subjective evaluation of his clinical performance, usually at the completion of five or six years at medical school. The evaluation is performed on an inadequate and uncontrolled patient sample and appears to be subject to many errors. Recent work…

  10. Clinical Positioning Space

    DEFF Research Database (Denmark)

    Williams, Lars Peter Hedegaard; Christensen, Mette Krogh; Rytter, Carsten

    2014-01-01

    In this article, we present a case study of residents’ clinical experiences and communication in outpatient oncology consultations. We apply positioning theory, a dynamic alternative to role theory, to investigate how oncology residents and patients situate themselves as persons with rights and d...

  11. Hepatitis C: Clinical Trials

    Science.gov (United States)

    ... will not know if you are taking the medicine or the placebo until the clinical trial is over. How do ... can already get by prescription ) or sugar pills ( placebos ) with the new medicine may last longer than Phases I and II ...

  12. The Unstructured Clinical Interview

    Science.gov (United States)

    Jones, Karyn Dayle

    2010-01-01

    In mental health, family, and community counseling settings, master's-level counselors engage in unstructured clinical interviewing to develop diagnoses based on the "Diagnostic and Statistical Manual of Mental Disorders" (4th ed., text rev.; "DSM-IV-TR"; American Psychiatric Association, 2000). Although counselors receive education about…

  13. Participating in Clinical Trials

    Medline Plus

    Full Text Available skip navigation Help Search home health topics A-Z Videos A-Z about us Customer Support NIH SeniorHealth Built with You in Mind Resize Text: A A A Change Contrast print sign up Share Home > Health topics A-Z > Participating in Clinical Trials: About ...

  14. Clinical Process Intelligence

    DEFF Research Database (Denmark)

    Vilstrup Pedersen, Klaus

    2006-01-01

    .e. local guidelines. From a knowledge management point of view, this externalization of generalized processes, gives the opportunity to learn from, evaluate and optimize the processes. "Clinical Process Intelligence" (CPI), will denote the goal of getting generalized insight into patient centered health...

  15. Variations in clinical estimates of tumor volume regression parameters and time factor during external radiotherapy in cancer cervix: Does it mimic the linear-quadratic model of cell survival?

    Directory of Open Access Journals (Sweden)

    Datta N

    2005-01-01

    Full Text Available BACKGROUND: Tumor regression parameters and time factor during external radiotherapy (EXTRT are of paramount importance. AIMS: To quantify the parameters of tumor regression and time factor during EXTRT in cancer cervix. SETTINGS AND DESIGN: Patients, treated solely with radiotherapy and enrolled for other prospective studies having weekly tumor regressions recorded were considered. MATERIALS AND METHODS: Seventy-seven patients received 50Gy of EXTRT followed by intracavitary brachytherapy. Loco-regional regressions were assessed clinically and regression fraction (RF was represented as RF = c + a1D + a2D2- a3T, with c, D and T as constant, cumulative EXTRT dose and treatment time respectively. STATISTICAL ANALYSIS USED: Step wise linear regression was performed for RF. Scatter plots were fitted using linear-quadratic fit. RESULTS: Coefficients of parameters D, D2 and T were computed for various dose intervals, namely 0-20 Gy, 0-30 Gy, 0-40 Gy and 0-50 Gy. At 0-20 Gy and 0-30 Gy, only the coefficient of D2 was significant (P < 0.001, while both D2 and T turned significant (P < 0.001 at 0-40 Gy. For the entire range of 0-50 Gy, all the coefficients of D, D2 and T showed significance, leading to an estimate of 26 Gy for a1/a2 and 0.96 Gy/day for a3/a1. CONCLUSIONS: As with a/β and g/a of post-irradiation cell survival curves, a1/a2 and a3/a1 represents the cumulative effect of various radiobiological factors influencing clinical regression of tumor during the course of EXTRT. The dynamic changes in the coefficients of D, D2sub and T, indicate their relative importance during various phases of EXTRT.

  16. [Management in clinical nutrition].

    Science.gov (United States)

    Alvarez, J; Monereo, S; Ortiz, P; Salido, C

    2004-01-01

    Terms such as management, costs, efficacy, efficiency, etc. that are so common in the discourse of managers are now beginning to appear in the vocabulary of clinicians. Management in Clinical Nutrition is an innovative aspect of interest among health-care professionals dealing with the needs of undernourished patients or those at risk of malnutrition. The basic goal of this paper is to show that the tools for clinical management of hospitals are applicable to such a multidisciplinary and complex speciality as clinical nutrition and also to propose the measures needed to improve our information systems and optimize management in this field. The very concept of hospitals has changed, as has their activity, over the years. Hospitals are nowadays no longer just a charitable institution but has become a service company, a public utility for the promotion of good health and they have to be managed in accordance with criteria of efficacy, efficiency, equity and quality. The concepts of Evidence-Based Medicine (EBM) and Cost-Effective Medicine (CEM) are of evident importance in the different ways of managing health-care services. Good clinical practice is the combination of EBM and CEM. This review defines the various cost studies of fundamental importance when taking decisions in hospital management and analyzes such clinical management tools as analytical accounting, Minimum Hospital Database Set (MHDS) and encoding systems, among others, thus facilitating an analysis of the usefulness of data in clinical nutrition management systems. Finally, after reviewing some specific examples, measures are proposed to optimize current information systems. The medical staff and those of us responsible for Nutrition Units operate in hospitals as part of a centralized service transferring information to the various departments where the patient is physically located (Surgery, Internal Medicine, Digestive, ICU, etc.). One of the priority goals in micro-management and middle management

  17. Computers and clinical arrhythmias.

    Science.gov (United States)

    Knoebel, S B; Lovelace, D E

    1983-02-01

    Cardiac arrhythmias are ubiquitous in normal and abnormal hearts. These disorders may be life-threatening or benign, symptomatic or unrecognized. Arrhythmias may be the precursor of sudden death, a cause or effect of cardiac failure, a clinical reflection of acute or chronic disorders, or a manifestation of extracardiac conditions. Progress is being made toward unraveling the diagnostic and therapeutic problems involved in arrhythmogenesis. Many of the advances would not be possible, however, without the availability of computer technology. To preserve the proper balance and purposeful progression of computer usage, engineers and physicians have been exhorted not to work independently in this field. Both should learn some of the other's trade. The two disciplines need to come together to solve important problems with computers in cardiology. The intent of this article was to acquaint the practicing cardiologist with some of the extant and envisioned computer applications and some of the problems with both. We conclude that computer-based database management systems are necessary for sorting out the clinical factors of relevance for arrhythmogenesis, but computer database management systems are beset with problems that will require sophisticated solutions. The technology for detecting arrhythmias on routine electrocardiograms is quite good but human over-reading is still required, and the rationale for computer application in this setting is questionable. Systems for qualitative, continuous monitoring and review of extended time ECG recordings are adequate with proper noise rejection algorithms and editing capabilities. The systems are limited presently for clinical application to the recognition of ectopic rhythms and significant pauses. Attention should now be turned to the clinical goals for detection and quantification of arrhythmias. We should be asking the following questions: How quantitative do systems need to be? Are computers required for the detection of

  18. Composição química e atividade antioxidante do óleo volátil de Eupatorium polystachyum DC Chemical composition and antioxidant activity of the volatile oil from Eupatorium polystachyum DC

    Directory of Open Access Journals (Sweden)

    Tiago J. T. Souza

    2007-09-01

    Full Text Available Os óleos voláteis das folhas e inflorescências de Eupatorium polystachyum DC. (Asteraceae, coletado no Rio Grande do Sul, Brasil, foram caracterizados por CG-EM e sua atividade antioxidante foi avaliada utilizando-se o método de DPPH. Foram obtidos rendimentos de 1,6 e 0,9% de óleo em relação às folhas e inflorescências frescas, sendo identificados 34 compostos, correspondendo a 99,1 e 99,5% do óleo volátil, respectivamente. Os óleos apresentaram exclusivamente compostos terpênicos, sendo que as folhas contêm grande quantidade de monoterpenos (66,4% enquanto que as inflorescências apresentaram quantidades equivalentes de mono e sesquiterpenos (51,8 e 47,7%, respectivamente. As amostras apresentaram-se qualitativamente muito semelhantes sendo constituídas majoritariamente por: beta-pineno (14,7 e 9,8%, beta-mirceno (15,3 e 10,8% e limoneno (22,8 e 20,5% entre os monoterpenos e beta-cariofileno (10,4 e 15,4%, germacreno D (7,2 e 9,4% e biciclogermacreno (12,0 e 19,2% entre os sesquiterpenos. As diferenças entre as amostras foram basicamente quantitativas. Os óleos apresentaram atividade antioxidante pelo ensaio com DPPH por bioautografia na diluição de 1:10 em éter etílico (v/v.The essential oil obtained from leaves and flowers of Eupatorium polystachyum DC. (Asteraceae collected in Rio Grande do Sul State, Brazil, was characterized by GC-MS and its antioxidant activity was assessed by DPPH assay. The yield of essential oil, relative to fresh material, was 1.6 and 0.9% for leaves and flowers, respectively. Both oils are constituted exclusively by terpenic compounds. Leaf oil contains great quantity of monoterpenes (66.4%; on the other hand, inflorescence oil contains comparable quantities of mono- and sesquiterpenes (51.8 and 47.7%, respectively. The same compounds are majority in both oils: beta-pinene (14.7 and 9.8%, beta-myrcene (15.3 and 10.8% and limonene (22.8 and 20.5% among monoterpenes and beta-caryophyllene (10

  19. Stratégies pour un vol virtuel : exemple de paysages brésiliens Estratégias para o voo virtual: exemplo de paisagens brasileiras Strategies for a virtual flight: the example of Brazilian landscapes

    Directory of Open Access Journals (Sweden)

    Alfredo Pereira de Queiroz Filho

    2011-03-01

    Full Text Available Ce travail aborde les deux principaux problèmes posés par le vol virtuel, l’orientation spatiale et la surcharge cognitive, et propose des stratégies qui facilitent la pratique de la navigation. Pour illustrer cette recherche, sont utilisés des exemples de paysages reconnus du territoire brésiliens, tels que Foz de Iguaçu (Paraná, Rio de Janeiro (État de Rio de Janeiro, Pantanal – (Mato Grosso du Sud, Salvador (Bahia, Belém (Pará, Manaus (Amazonas, et São Paulo (État de São Paulo.Este trabalho aborda os dois principais problemas do vôo virtual, a orientação espacial e a sobrecarga cognitiva, e propõe estratégias para auxiliar na sua navegação. Para ilustrar a pesquisa, são usados exemplos de consagradas paisagens do território brasileiro, como Foz do Iguaçu - PR, Rio de Janeiro - RJ, Pantanal - MS, Salvador - BA, Belém - PA, Manaus – MA e São Paulo – SP.This paper approaches the two main problems of the virtual flight, spatial orientation and cognitive overload, and proposes strategies to assist in its navigation. To illustrate the research, examples are used to dealing landscapes of the Brazilian territory, as Foz do Iguaçu - PR, Rio de Janeiro - RJ, Pantanal - MS, Salvador - BA, Belém - PA, Manaus - AM and São Paulo - SP

  20. Research and Design of VoIP Based on Softswitch%基于软交换体系下的VolP技术的研究与设计

    Institute of Scientific and Technical Information of China (English)

    余建明

    2011-01-01

    How about VoIP fussing with the next generation of network is a very fashionable topic for discussion. because of the gateway of VolP bases on (GW-GK)the function ,whose function is too concentrates, equipment is too complex and capacity is limited, this article will pull apart the gateway two part ,which enable the gateway only corresponding the transmission of medium and the function of call control will be completed by the Softswitch, with the aiddtion of the idea of softswitch which the service/control don' t concern the transmission/access. Not only resolve the question of the capacity ,but also easy to be maintained and managed.%VoIP如何与下一代网络融合是目前比较热门的讨论话题,由于目前基于网关一网守(G、nGK)的VoIP网络中网关功能过于集中,设备过于复杂以及容量受限的问题,本文将借助软交换的业务/控制与传送/接入分离的思想,将网关分离使网关只负责媒体的传输,呼叫控制功能由软交换设备来完成,不仅解决了容量问题,而且易于维护和管理。

  1. Clinical physiopathology of hypernatremia

    Directory of Open Access Journals (Sweden)

    F. Sgambato

    2013-05-01

    Full Text Available BACKGROUND The maintenance of sodium levels at normal ranges has to be considered one of the most important and crucial physiological balance in order to preserve life. The increase of natremia determines the leakage of H2O from the inside of cells and the consequent brain cells withering, that causes encephalopathy at different stages and in some cases it can even lead to death. AIM OF THE STUDY The fundamentals of general physiopathology are analysed together with systems of compensation and brain adaptation in the three different aetiopathogenetic forms: primary increase of sodium (hypervolemic and haedematose form; missed introduction of pure water (mainly euvolemic form, with no aedema; loss of hypotonic fluids (hypovolemic form with dehydration. The three different clinical entities with their relative clinical approaches have been described.

  2. Clinical Supervision in Denmark

    DEFF Research Database (Denmark)

    Jacobsen, Claus Haugaard

    2011-01-01

    Aim: Supervision is a vital factor in the professional development of psychotherapists, and was rated by novice therapists as the most important factor in their own current development (Orlinsky & Rønnestad, 2005). Paradoxically, the standard version of the Development of Psychotherapists Common...... Core Questionnaire (DPCCQ) has only few questions on supervision. To rectify this limitation, a recent Danish version of the DPCCQ included two new sections on supervision, one focusing on supervisees and another on supervisors and their supervisory training. This paper presents our initial findings...... on giving and receiving clinical supervision as reported by therapists in Denmark. Method: Currently, the Danish sample consists of 350 clinical psychologist doing psychotherapy who completed DPCCQ. Data are currently being prepared for statistical analysis. Results: This paper will focus primarily...

  3. [Clinical diagnosis of dyslexia].

    Science.gov (United States)

    Martínez Hermosillo, A; Balderas Gil, A

    1980-01-01

    In 5 years of experience at the Instituto Nacional de la Comunicacion Humana, 302 clinical histories showed the diagnosis of dyslexia. The following parameters were studied: age, sex, heredofamilial history, gestation, psychomotor development, clinical picture, examination of the language (type, reading, spontaneous writing, dictation, mathematic concepts), laterality, scholarship, scholar failures, psychological study. The following results were obtained: Dyslexia was more important or frequent between 5 to 8.9 years of age. Males predominated 3:1. The heredofamilial history was important. Dyslexia prevailed in products of the first gestations. A high disturbance was found in the psychomotor development of a large percent of dyslexic patients. Examination of language was also important. Dyslexia was more frequent in right-handed patients. Scholar failures in one or more instances were found. The psychological study must be done. If dyslexia is diagnosed on time, it may be prevented and all unwanted sequelae may be avoided.

  4. Clinical Applications for Estetrol

    Directory of Open Access Journals (Sweden)

    Visser M

    2010-01-01

    Full Text Available In this paper the potential clinical applications for the human fetal estrogen estetrol (E4 are presented based on recently obtained data in preclinical and clinical studies. In the past E4 has been classified as a weak estrogen due to its rather low estrogen receptor affinity. However, recent research has demonstrated that due to its favorable pharmacokinetic properties, especially the slow elimination and long half-life, E4 is an effective orally bioavailable estrogen agonist with estrogen antagonistic effects on the breast in the presence of estradiol. Based on the pharmacokinetic properties, the pharmacological profile and the safety and efficacy results in human studies, E4 seems potentially suitable as a drug for human use in applications such as hormone replacement therapy (vaginal atrophy and vasomotor symptoms, contraception, osteoporosis and breast cancer.

  5. Mosaicism and clinical genetics.

    Science.gov (United States)

    Spinner, Nancy B; Conlin, Laura K

    2014-12-01

    With the introduction of increasingly sensitive technologies for mutation detection such as chromosomal microarrays and next-generation sequencing, the importance of mosaicism for human disease is being more fully appreciated. Mosaicism can occur for any type of mutation, either at the chromosomal or DNA sequence level, and while in many cases mosaicism can modify the clinical effects of a syndrome, there are many alterations that can only occur in mosaic form as the mutation is lethal when present in every cell. Mosaicism can have a wide range of effects, from early pregnancy loss, to organ specific pathology, to modification of clinical syndromes. Recent evidence reveals that generation of mosaic alterations is associated with aging, and our ability to detect mosaic alterations sheds light on normal and pathologic changes across the lifespan.

  6. [Clinically documented fungal infections].

    Science.gov (United States)

    Kakeya, Hiroshi; Kohno, Shigeru

    2008-12-01

    Proven fungal infections are diagnosed by histological/microbiological evidence of fungi at the site of infection and positive blood culture (fungemia). However, invasive diagnosing examinations are not always applied for all of immunocompromised patients. Clinically documented invasive fungal infections are diagnosed by typical radiological findings such as halo sign on chest CT plus positive serological/molecular evidence of fungi. Serological tests of Aspergillus galactomannan antigen and beta-glucan for aspergillosis and cryptococcal glucuronoxylomannan antigen for cryptococcosis are useful. Hence, none of reliable serological tests for zygomycosis are available so far. In this article, risk factors, sign and symptoms, and diagnostic methods for clinically documented cases of invasive aspergillosis, pulmonary cryptococcosis, and zygomycosis with diabates, are reviewed.

  7. Evidence and clinical judgement.

    Science.gov (United States)

    Macnaughton, R J

    1998-05-01

    Widespread acceptance of the neologism 'evidence-based medicine' (EBM) has had the consequences of obscuring what evidence really is, and of eroding the importance of judgement in clinical situations. In this essay I seek to correct this lack of balance in the view of clinical encounters as portrayed by EBM. A better understanding of what evidence is can be obtained by looking beyond medicine to the way in which scientists and detectives view evidence. In both spheres, the importance of judgement is emphasized, even if it is a technical type of judgement. Clinicians also employ a technical kind of judgement, similar to that in science and detective work, when assessing the evidence relating to the truth of a diagnosis for an individual patient; but judgements relating to the ongoing care and treatment of that patient are based on what Aristotle calls phronesis or 'practical wisdom'.

  8. [Neuroethics in clinical practice].

    Science.gov (United States)

    Krug, H

    2009-08-01

    In recent years the ability of neuroscience to identify and intervene in mental functions has progressed immensely, which raises several anthropologic and ethical questions. Meanwhile neuroethics arose as a new interdisciplinary field for critical analysis of neuroscientific actions and ethical reflection on the increasing knowledge of the human brain, with regard to society and politics. This article provides a survey of neuroethical implications for clinical practice.

  9. Horizons in clinical nanomedicine

    CERN Document Server

    Karagkiozaki, Varvara

    2014-01-01

    Nanomedicine-the application of nanotechnology to health sciences-has the potential to address many important medical problems by exploiting the advanced physicochemical characteristics of nanostructured materials and devices. It can revolutionize conventional medicine by offering cutting-edge developments in the processes of diagnosing, treating, and preventing diseases, injuries, or genetic disorders. Thus, clinical nanomedicine holds promise to preserve and improve human health.This book provides a comprehensive overview on the forefront developments of nanotechnology in various domains of

  10. Tianeptine - A Clinical Review.

    OpenAIRE

    More Patil Vidita; More Patil Vrunda; Yadav KS; Gomes M

    2016-01-01

    Depression is a wide spread disorder. The development of effective pharmacotherapy for major depression is important because it is such a widespread and debilitating mental disorder. The following review is based on the preclinical and clinical studies carried out on Tianeptine, an atypical antidepressant that lowers the adverse effects of stress on brain and memory. It is one of the many drugs being tested these days in the market as nootropics; it is presented as a “Smart Drug”. These are b...

  11. [Clinical spectrum of neuroborreliosis].

    Science.gov (United States)

    Owecki, Michał K; Kozubski, Wojciech

    2007-01-01

    Lyme disease is a multisystem infectious disease with a wide variety of symptoms involving the skin as well as nervous, musculosceletal and cardiovascular systems. Lyme disease is caused by spirochaete Borrelia burgdorferi transmitted by Ixodes tics in endemic regions. The diverse manifestations of neuroborreliosis require it to be included in differential diagnosis of many neurological disorders. The paper reviews the spectrum of clinical symptoms of nervous system involvement in early and late Lyme disease.

  12. [Guidelines for clinical practice].

    Science.gov (United States)

    Vleugels, A M

    1997-01-01

    Clinical practice guidelines are systematically developed statements that are intended to support medical decision making in well-defined clinical situations. Essentially, their object is to reduce the variability in medical practice, to improve quality, and to make appropriated control of the financial resources possible. Internationally, ever more organisations, associations, and institutions are concerned with the development of guidelines in many different areas of care. Making implicit knowledge explicit is one of the associated advantages of guidelines: they have a potential utility in training, in process evaluation, and in the reevaluation of outcome studies. In liability issues, their existence has a double effect: they can be used to justify medical behaviour, and they constitute a generally accepted reference point. A derivative problem is the legal liability of the compilers of the guidelines. The principle of the guideline approach can be challenged academically: science cannot give a definition of optimal care with absolute certainty. What is called objectivity often rests on methodologically disputable analyses; also the opinion of opinion leaders is not always a guarantee for scientific soundness. Moreover, patients are not all identical: biological variability, situational factors, patient expectations, and other elements play a role in this differentiation. Clinicians are often hesitant with respect to clinical guidelines: they are afraid of cookbook medicine and curtailment of their professional autonomy. Patients fear reduction of individualization of care and the use of guidelines as a rationing instrument. The effects of the introduction of clinical practice guidelines on medical practice, on the results and on the cost of care vary but are generally considered to be favourable. The choice of appropriate strategies in development, dissemination, and implementation turns out to be of critical importance. The article ends with concrete

  13. Clinical versus actuarial judgment.

    Science.gov (United States)

    Dawes, R M; Faust, D; Meehl, P E

    1989-03-31

    Professionals are frequently consulted to diagnose and predict human behavior; optimal treatment and planning often hinge on the consultant's judgmental accuracy. The consultant may rely on one of two contrasting approaches to decision-making--the clinical and actuarial methods. Research comparing these two approaches shows the actuarial method to be superior. Factors underlying the greater accuracy of actuarial methods, sources of resistance to the scientific findings, and the benefits of increased reliance on actuarial approaches are discussed.

  14. Clinical highlights from Amsterdam

    Directory of Open Access Journals (Sweden)

    Jouke T. Annema

    2016-07-01

    Full Text Available This article contains highlights and a selection of the scientific advances from the Clinical Assembly that were presented at the 2015 European Respiratory Society International Congress in Amsterdam, the Netherlands. The most relevant topics for clinicians will be discussed, covering a wide range of areas including interventional pulmonology, rehabilitation and chronic care, thoracic imaging, diffuse and parenchymal lung diseases, and general practice and primary care. In this comprehensive review, exciting novel data will be discussed and put into perspective.

  15. Psychiatrists and clinical psychologists

    Directory of Open Access Journals (Sweden)

    Ajai R. Singh

    2006-03-01

    Full Text Available Psychiatrists and clinical psychologists share an inevitable, if rather uneasy, relationship. So very much like a modern marriage. Can't do without it, can't get out of it. Both sides contemplate divorce often. Think of separation by mutual consent. Even keep threatening as they rave and rant. Have secret, and not so secret, flings on the side. But, like the proverbial homing bird, or the conservative Indian arranged marriage, have no option but to stick it out with each other. Psychiatrists are otherwise good people. But that does not make them immune to handling clinical psychologists with the condescending tolerance and patronizing acceptance that teachers, for example, have towards rambling students. Or the rich have towards the poor. This does not take long to get converted into exasperation and smirky asides in the less charitable amongst the psychiatrists. Not that clinical psychologists are very helpful in motivating the psychiatrists to change for the better. For they, like most people in their position, over react and get aggressive when confronted with this attitude. And understandably so. However, it is time both realized their attitudes were not helpful either for mutual interaction, or growth of the Mental Health Movement at large. We can understand why psychiatrists behave the way they do. They are exposed to this same condescending-patronising attitude from their own peers in the medical profession. Their medical colleagues have yet to develop a feeling of healthy respect for psychiatry. Psychiatrists, no doubt, feel this is unjustified, but their peers are still in a position to deny them the respect and acceptance they seek. What they get from their medical colleagues, they unwittingly pass on to their clinical psychologist colleagues. But understanding why it occurs does not absolve them of their responsibility to behave more rationally, rather than emotionally, with the latter. [No abstract available.

  16. Rural health clinics infrastructure

    Energy Technology Data Exchange (ETDEWEB)

    Olson, K.

    1997-12-01

    The author discusses programs which were directed at the installation of photovoltaic power systems in rural health clinics. The objectives included: vaccine refrigeration; ice pack freezing; lighting; communications; medical appliances; sterilization; water purification; and income generation. The paper discusses two case histories, one in the Dominican Republic and one in Colombia. The author summarizes the results of the programs, both successes and failures, and offers an array of conclusions with regard to the implementation of future programs of this general nature.

  17. Clinical multiphoton FLIM tomography

    Science.gov (United States)

    König, Karsten

    2012-03-01

    This paper gives an overview on current clinical high resolution multiphoton fluorescence lifetime imaging in volunteers and patients. Fluorescence lifetime imaging (FLIM) in Life Sciences was introduced in Jena/Germany in 1988/89 based on a ZEISS confocal picosecond dye laser scanning microscope equipped with a single photon counting unit. The porphyrin distribution in living cells and living tumor-bearing mice was studied with high spatial, temporal, and spectral resolution. Ten years later, time-gated cameras were employed to detect dental caries in volunteers based on one-photon excitation of autofluorescent bacteria with long fluorescence lifetimes. Nowadays, one-photon FLIM based on picosecond VIS laser diodes are used to study ocular diseases in humans. Already one decade ago, first clinical twophoton FLIM images in humans were taken with the certified clinical multiphoton femtosecond laser tomograph DermaInspectTM. Multiphoton tomographs with FLIM modules are now operating in hospitals at Brisbane, Tokyo, Berlin, Paris, London, Modena and other European cities. Multiple FLIM detectors allow spectral FLIM with a temporal resolution down to 20 ps (MCP) / 250 ps (PMT) and a spectral resolution of 10 nm. Major FLIM applications include the detection of intradermal sunscreen and tattoo nanoparticles, the detection of different melanin types, the early diagnosis of dermatitis and malignant melanoma, as well as the measurement of therapeutic effects in pateints suffering from dermatitis. So far, more than 1,000 patients and volunteers have been investigated with the clinical multiphoton FLIM tomographs DermaInspectTM and MPTflexTM.

  18. Myocarditis in Clinical Practice.

    Science.gov (United States)

    Sinagra, Gianfranco; Anzini, Marco; Pereira, Naveen L; Bussani, Rossana; Finocchiaro, Gherardo; Bartunek, Jozef; Merlo, Marco

    2016-09-01

    Myocarditis is a polymorphic disease characterized by great variability in clinical presentation and evolution. Patients presenting with severe left ventricular dysfunction and life-threatening arrhythmias represent a demanding challenge for the clinician. Modern techniques of cardiovascular imaging and the exhaustive molecular evaluation of the myocardium with endomyocardial biopsy have provided valuable insight into the pathophysiology of this disease, and several clinical registries have unraveled the disease's long-term evolution and prognosis. However, uncertainties persist in crucial practical issues in the management of patients. This article critically reviews current information for evidence-based management, offering a rational and practical approach to patients with myocarditis. For this review, we searched the PubMed and MEDLINE databases for articles published from January 1, 1980, through December 31, 2015, using the following terms: myocarditis, inflammatory cardiomyopathy, and endomyocardial biopsy. Articles were selected for inclusion if they represented primary data or were review articles published in high-impact journals. In particular, a risk-oriented approach is proposed. The different patterns of presentation of myocarditis are classified as low-, intermediate-, and high-risk syndromes according to the most recent evidence on prognosis, clinical findings, and both invasive and noninvasive testing, and appropriate management strategies are proposed for each risk class.

  19. Gateways to clinical trials.

    Science.gov (United States)

    Bayés, M; Rabasseda, X; Prous, J R

    2007-01-01

    Gateways to Clinical Trials are a guide to the most recent clinical trials in current literature and congresses. The data the following tables have been retrieved from the Clinical Trials Knowledge Area of Prous Science Integrity, the drug discovery and development portal, http://integrity.prous.com. This issues focuses on the following selection of drugs: 4'-Thio-ara-C, 5-methyltetrahydrofolate; ABT-089, AD-237, AF-37702, alvocidib hydrochloride, apricitabine, armodafinil, atrasentan, AVE-5883, avian influenza vaccine, azimilide hydrochloride; Banoxantrone, BIBF-1120; CD34+ cells, certolizumab pegol, CHIR-258, cilansetron, CoFactor, CX-3543, cystemustine; D-003, dexloxiglumide, DMXB-anabaseine; Ecogramostim, elcometrine, elcometrine/ethinylestradiol, etravirine; Fenretinide, fingolimod hydrochloride, fospropofol disodium; Gaboxadol, gestodene, glutamine; Human insulin, hyaluronic acid; Incyclinide, indacaterol, ispronicline, istradefylline; Labradimil, lamifiban, lapatinib, L-arginine hydrochloride, liposomal cisplatin, liposome encapsulated paclitaxel, LY-517717; Manidipine hydrochloride/delapril hydrochloride, maraviroc, MBP(82-98), MD-0727, MDX-214, melanotan I, MMR vaccine; Nacystelyn, nalfurafine hydrochloride, nibentan, nilotinib, NK-105; OBI-1, oblimersen sodium, olmesartan medoxomil, olmesartan medoxomil/hydrochlorothiazide, oregovomab; Pexelizumab, PG-116800, PG-CPT, PHA-794428, prasugrel; RC-3095, rDNA insulin, RFB4(dsFv)-PE38, rhEndostatin, rhenium Re-186 etidronate, rhGM-CSF, roflumilast, romidepsin; Sarcosine, SGLU1, SGN-40, succinobucol; TAU, teduglutide, telatinib, tesofensine, tipifarnib, tirapazamine, TKA-731, tolvaptan, trabectedin; Vaccimel, vatalanib succinate, velafermin, vildagliptin, vinflunine; XP-19986; YM-155.

  20. Neurosurgery and clinical engineering.

    Science.gov (United States)

    Salcman, M; Samaras, G M

    1978-01-01

    Modern technology has profoundly altered the clinical practice of neurosurgery. For a wide variety of conditions, patients are being implanted with active and passive devices or treated with advanced microsurgical instrumentation. After surgery, such patients are sent to modern intensive-care units employing the latest advances in patient monitoring and computer technology. We contend that the responsibilities of the Clinical Engineer extend beyond simple installation and maintenance of equipment and systems. It is essential that he take part in the continuing education of non-technical personnel who must make use of the equipment in ways that are meaningful in the care of the patient and to the progress of clinical science. This point is illustrated by our experience with a neurosurgical intensive-care unit. It is also the thesis of this paper that the design and maintenance of increasingly sophisticated biomedical systems will benefit from the use of an interdisciplinary approach at the very inception of a project. This approach is illustrated by our current development of a multibeam microwave hyperthermia system for possible use in the treatment of brain tumors.