WorldWideScience

Sample records for clinical linear accelerators

  1. Clinical implementation of electron energy changes of varian linear accelerators.

    Science.gov (United States)

    Zhang, Sean; Liengsawangwong, Praimakorn; Lindsay, Patricia; Prado, Karl; Sun, Tzouh-Liang; Steadham, Roy; Wang, Xiaochun; Salehpour, Mohammad; Gillin, Michael

    2009-10-27

    Modern dual photon energy linear accelerators often come with a few megavoltage electron beams. The megavoltage electron beam has limited range and relative sharp distal falloff in its depth dose curve compared to that of megavoltage photon beam. Its radiation dose is often delivered appositionally to cover the target volume to its distal 90% depth dose (d90), while avoiding the normal--sometimes critical--structure immediately distal to the target. Varian linear accelerators currently offer selected electron beams of 4, 6, 9, 12, 16 and 20 MeV electron beam energies. However, intermediate electron energy is often needed for optimal dose distribution. In this study we investigated electron beam characteristics and implemented two intermediate 7 and 11 MeV electron beams on Varian linear accelerators. Comprehensive tests and measurements indicated the new electron beams met all dosimetry parameter criteria and operational safety standards. Between the two new electron beams and the existing electron beams we were able to provide a choice of electron beams of 4, 6, 7, 9, 11, 12, 16 and 20 MeV electron energies, which had d90 depth between 1.5 cm and 6.0 cm (from 1.5 cm to 4.0 cm in 0.5 cm increments) to meet our clinical needs.

  2. Ant colony method to control variance reduction techniques in the Monte Carlo simulation of clinical electron linear accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Pareja, S. [Servicio de Radiofisica Hospitalaria, Hospital Regional Universitario ' Carlos Haya' , Avda. Carlos Haya, s/n, E-29010 Malaga (Spain)], E-mail: garciapareja@gmail.com; Vilches, M. [Servicio de Fisica y Proteccion Radiologica, Hospital Regional Universitario ' Virgen de las Nieves' , Avda. de las Fuerzas Armadas, 2, E-18014 Granada (Spain); Lallena, A.M. [Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain)

    2007-09-21

    The ant colony method is used to control the application of variance reduction techniques to the simulation of clinical electron linear accelerators of use in cancer therapy. In particular, splitting and Russian roulette, two standard variance reduction methods, are considered. The approach can be applied to any accelerator in a straightforward way and permits, in addition, to investigate the 'hot' regions of the accelerator, an information which is basic to develop a source model for this therapy tool.

  3. Clinical commissioning and use of the Novalis Tx linear accelerator for SRS and SBRT.

    Science.gov (United States)

    Kim, Jinkoo; Wen, Ning; Jin, Jian-Yue; Walls, Nicole; Kim, Sangroh; Li, Haisen; Ren, Lei; Huang, Yimei; Doemer, Anthony; Faber, Kathleen; Kunkel, Tina; Balawi, Ahssan; Garbarino, Kimberly; Levin, Kenneth; Patel, Samir; Ajlouni, Munther; Miller, Brett; Nurushev, Teamor; Huntzinger, Calvin; Schulz, Raymond; Chetty, Indrin J; Movsas, Benjamin; Ryu, Samuel

    2012-05-10

    The purpose of this study was to perform comprehensive measurements and testing of a Novalis Tx linear accelerator, and to develop technical guidelines for com-missioning from the time of acceptance testing to the first clinical treatment. The Novalis Tx (NTX) linear accelerator is equipped with, among other features, a high-definition MLC (HD120 MLC) with 2.5 mm central leaves, a 6D robotic couch, an optical guidance positioning system, as well as X-ray-based image guidance tools to provide high accuracy radiation delivery for stereotactic radiosurgery and stereotactic body radiation therapy procedures. We have performed extensive tests for each of the components, and analyzed the clinical data collected in our clinic. We present technical guidelines in this report focusing on methods for: (1) efficient and accurate beam data collection for commissioning treatment planning systems, including small field output measurements conducted using a wide range of detectors; (2) commissioning tests for the HD120 MLC; (3) data collection for the baseline characteristics of the on-board imager (OBI) and ExacTrac X-ray (ETX) image guidance systems in conjunction with the 6D robotic couch; and (4) end-to-end testing of the entire clinical process. Established from our clinical experience thus far, recommendations are provided for accurate and efficient use of the OBI and ETX localization systems for intra- and extracranial treatment sites. Four results are presented. (1) Basic beam data measurements: Our measurements confirmed the necessity of using small detectors for small fields. Total scatter factors varied significantly (30% to approximately 62%) for small field measurements among detectors. Unshielded stereotactic field diode (SFD) overestimated dose by ~ 2% for large field sizes. Ion chambers with active diameters of 6 mm suffered from significant volume averaging. The sharpest profile penumbra was observed for the SFD because of its small active diameter (0.6 mm). (2

  4. Berkeley Proton Linear Accelerator

    Science.gov (United States)

    Alvarez, L. W.; Bradner, H.; Franck, J.; Gordon, H.; Gow, J. D.; Marshall, L. C.; Oppenheimer, F. F.; Panofsky, W. K. H.; Richman, C.; Woodyard, J. R.

    1953-10-13

    A linear accelerator, which increases the energy of protons from a 4 Mev Van de Graaff injector, to a final energy of 31.5 Mev, has been constructed. The accelerator consists of a cavity 40 feet long and 39 inches in diameter, excited at resonance in a longitudinal electric mode with a radio-frequency power of about 2.2 x 10{sup 6} watts peak at 202.5 mc. Acceleration is made possible by the introduction of 46 axial "drift tubes" into the cavity, which is designed such that the particles traverse the distance between the centers of successive tubes in one cycle of the r.f. power. The protons are longitudinally stable as in the synchrotron, and are stabilized transversely by the action of converging fields produced by focusing grids. The electrical cavity is constructed like an inverted airplane fuselage and is supported in a vacuum tank. Power is supplied by 9 high powered oscillators fed from a pulse generator of the artificial transmission line type.

  5. Application of variance reduction techniques in Monte Carlo simulation of clinical electron linear accelerator

    Science.gov (United States)

    Zoubair, M.; El Bardouni, T.; El Gonnouni, L.; Boulaich, Y.; El Bakkari, B.; El Younoussi, C.

    2012-01-01

    Computation time constitutes an important and a problematic parameter in Monte Carlo simulations, which is inversely proportional to the statistical errors so there comes the idea to use the variance reduction techniques. These techniques play an important role in reducing uncertainties and improving the statistical results. Several variance reduction techniques have been developed. The most known are Transport cutoffs, Interaction forcing, Bremsstrahlung splitting and Russian roulette. Also, the use of a phase space seems to be appropriate to reduce enormously the computing time. In this work, we applied these techniques on a linear accelerator (LINAC) using the MCNPX computer Monte Carlo code. This code gives a rich palette of variance reduction techniques. In this study we investigated various cards related to the variance reduction techniques provided by MCNPX. The parameters found in this study are warranted to be used efficiently in MCNPX code. Final calculations are performed in two steps that are related by a phase space. Results show that, comparatively to direct simulations (without neither variance-reduction nor phase space), the adopted method allows an improvement in the simulation efficiency by a factor greater than 700.

  6. Clinic based transfer of the N(D,W)(60Co) calibration coefficient using a linear accelerator.

    Science.gov (United States)

    Abdel-Rahman, W; Evans, M D C; Serré, L; McCaffrey, J P; Podgorsak, E B; Seuntjens, J P

    2009-03-01

    Ionization chambers used for reference dosimetry require a local secondary standard ionization chamber with a 60Co absorbed dose to water calibration coefficient N(D,W)(60Co) traceable to a national primary standards dosimetry laboratory or an accredited secondary dosimetry calibration laboratory. Clinic based (in-house) transfer of this coefficient to tertiary reference ionization chambers has traditionally been accomplished with chamber cross calibration in water using a 60Co beam; however, access to 60Co teletherapy machines has become increasingly limited for clinic based physicists. In this work, the accuracy of alternative methods of transferring the N(D,W)(60Co) calibration coefficient using 6 and 18 MV photon beams from a linear accelerator in lieu of 60Co has been investigated for five different setups and four commonly used chamber types.

  7. Direct reconstruction of the source intensity distribution of a clinical linear accelerator using a maximum likelihood expectation maximization algorithm.

    Science.gov (United States)

    Papaconstadopoulos, P; Levesque, I R; Maglieri, R; Seuntjens, J

    2016-02-07

    Direct determination of the source intensity distribution of clinical linear accelerators is still a challenging problem for small field beam modeling. Current techniques most often involve special equipment and are difficult to implement in the clinic. In this work we present a maximum-likelihood expectation-maximization (MLEM) approach to the source reconstruction problem utilizing small fields and a simple experimental set-up. The MLEM algorithm iteratively ray-traces photons from the source plane to the exit plane and extracts corrections based on photon fluence profile measurements. The photon fluence profiles were determined by dose profile film measurements in air using a high density thin foil as build-up material and an appropriate point spread function (PSF). The effect of other beam parameters and scatter sources was minimized by using the smallest field size ([Formula: see text] cm(2)). The source occlusion effect was reproduced by estimating the position of the collimating jaws during this process. The method was first benchmarked against simulations for a range of typical accelerator source sizes. The sources were reconstructed with an accuracy better than 0.12 mm in the full width at half maximum (FWHM) to the respective electron sources incident on the target. The estimated jaw positions agreed within 0.2 mm with the expected values. The reconstruction technique was also tested against measurements on a Varian Novalis Tx linear accelerator and compared to a previously commissioned Monte Carlo model. The reconstructed FWHM of the source agreed within 0.03 mm and 0.11 mm to the commissioned electron source in the crossplane and inplane orientations respectively. The impact of the jaw positioning, experimental and PSF uncertainties on the reconstructed source distribution was evaluated with the former presenting the dominant effect.

  8. Linear accelerator for radioisotope production

    Energy Technology Data Exchange (ETDEWEB)

    Hansborough, L.D.; Hamm, R.W.; Stovall, J.E.

    1982-02-01

    A 200- to 500-..mu..A source of 70- to 90-MeV protons would be a valuable asset to the nuclear medicine program. A linear accelerator (linac) can achieve this performance, and it can be extended to even higher energies and currents. Variable energy and current options are available. A 70-MeV linac is described, based on recent innovations in linear accelerator technology; it would be 27.3 m long and cost approx. $6 million. By operating the radio-frequency (rf) power system at a level necessary to produce a 500-..mu..A beam current, the cost of power deposited in the radioisotope-production target is comparable with existing cyclotrons. If the rf-power system is operated at full power, the same accelerator is capable of producing an 1140-..mu..A beam, and the cost per beam watt on the target is less than half that of comparable cyclotrons.

  9. Accelerating structure with linear excitation

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, J.; Srinivasan-Rao, T.

    1988-03-01

    The switched power linac (SPL) structures require a ring-shaped laser beam pulse of uniform intensity to avoid transverse field components of the accelerating field at the center. In order to also utilize the reflection of the outgoing EM wave, the switching element has to be very close to the outer edge of the structure to ensure nearly synchronous superposition at the beam hole with the original inward going wave. It is sometimes easier to produce linear (flat) laser beams, e.g., from powerful excimer lasers which have beams of rectangular cross section. Such flat beams could be used to excite linear photocathode switches or be used to produce flat electron beam pulses in electron sources. In this paper, an accelerator structure is proposed which may be considered a variant of the SPL disk structure, but could be used with linear beams. The structure utilizes a double parabolic horn. 8 refs., 9 figs.

  10. Repair of overheating linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Barkley, Walter; Baldwin, William; Bennett, Gloria; Bitteker, Leo; Borden, Michael; Casados, Jeff; Fitzgerald, Daniel; Gorman, Fred; Johnson, Kenneth; Kurennoy, Sergey; Martinez, Alberto; O’Hara, James; Perez, Edward; Roller, Brandon; Rybarcyk, Lawrence; Stark, Peter; Stockton, Jerry

    2004-01-01

    Los Alamos Neutron Science Center (LANSCE) is a proton accelerator that produces high energy particle beams for experiments. These beams include neutrons and protons for diverse uses including radiography, isotope production, small feature study, lattice vibrations and material science. The Drift Tube Linear Accelerator (DTL) is the first portion of a half mile long linear section of accelerator that raises the beam energy from 750 keV to 100 MeV. In its 31st year of operation (2003), the DTL experienced serious issues. The first problem was the inability to maintain resonant frequency at full power. The second problem was increased occurrences of over-temperature failure of cooling hoses. These shortcomings led to an investigation during the 2003 yearly preventative maintenance shutdown that showed evidence of excessive heating: discolored interior tank walls and coper oxide deposition in the cooling circuits. Since overheating was suspected to be caused by compromised heat transfer, improving that was the focus of the repair effort. Investigations revealed copper oxide flow inhibition and iron oxide scale build up. Acid cleaning was implemented with careful attention to protection of the base metal, selection of components to clean and minimization of exposure times. The effort has been very successful in bringing the accelerator through a complete eight month run cycle allowing an incredible array of scientific experiments to be completed this year (2003-2004). This paper will describe the systems, investigation analysis, repair, return to production and conclusion.

  11. Estimation of absorbed dose in clinical radiotherapy linear accelerator beams: Effect of ion chamber calibration and long-term stability.

    Science.gov (United States)

    Ravichandran, Ramamoorthy; Binukumar, Johnson Pichy; Davis, Cheriyathmanjiyil Antony

    2013-10-01

    The measured dose in water at reference point in phantom is a primary parameter for planning the treatment monitor units (MU); both in conventional and intensity modulated/image guided treatments. Traceability of dose accuracy therefore still depends mainly on the calibration factor of the ion chamber/dosimeter provided by the accredited Secondary Standard Dosimetry Laboratories (SSDLs), under International Atomic Energy Agency (IAEA) network of laboratories. The data related to Nd,water calibrations, thermoluminescent dosimetry (TLD) postal dose validation, inter-comparison of different dosimeter/electrometers, and validity of Nd,water calibrations obtained from different calibration laboratories were analyzed to find out the extent of accuracy achievable. Nd,w factors in Gray/Coulomb calibrated at IBA, GmBH, Germany showed a mean variation of about 0.2% increase per year in three Farmer chambers, in three subsequent calibrations. Another ion chamber calibrated in different accredited laboratory (PTW, Germany) showed consistent Nd,w for 9 years period. The Strontium-90 beta check source response indicated long-term stability of the ion chambers within 1% for three chambers. Results of IAEA postal TL "dose intercomparison" for three photon beams, 6 MV (two) and 15 MV (one), agreed well within our reported doses, with mean deviation of 0.03% (SD 0.87%) (n = 9). All the chamber/electrometer calibrated by a single SSDL realized absorbed doses in water within 0.13% standard deviations. However, about 1-2% differences in absorbed dose estimates observed when dosimeters calibrated from different calibration laboratories are compared in solid phantoms. Our data therefore imply that the dosimetry level maintained for clinical use of linear accelerator photon beams are within recommended levels of accuracy, and uncertainties are within reported values.

  12. Extrapolation chamber mounted on perspex for calibration of high energy photon and electron beams from a clinical linear accelerator

    Directory of Open Access Journals (Sweden)

    Ravichandran R

    2009-01-01

    Full Text Available The objective of the present study is to establish radiation standards for absorbed doses, for clinical high energy linear accelerator beams. In the nonavailability of a cobalt-60 beam for arriving at Nd, water values for thimble chambers, we investigated the efficacy of perspex mounted extrapolation chamber (EC used earlier for low energy x-rays and beta dosimetry. Extrapolation chamber with facility for achieving variable electrode separations 10.5mm to 0.5mm using micrometer screw was used for calibrations. Photon beams 6 MV and 15 MV and electron beams 6 MeV and 15 MeV from Varian Clinac linacs were calibrated. Absorbed Dose estimates to Perspex were converted into dose to solid water for comparison with FC 65 ionisation chamber measurements in water. Measurements made during the period December 2006 to June 2008 are considered for evaluation. Uncorrected ionization readings of EC for all the radiation beams over the entire period were within 2% showing the consistency of measurements. Absorbed doses estimated by EC were in good agreement with in-water calibrations within 2% for photons and electron beams. The present results suggest that extrapolation chambers can be considered as an independent measuring system for absorbed dose in addition to Farmer type ion chambers. In the absence of standard beam quality (Co-60 radiations as reference Quality for Nd,water the possibility of keeping EC as Primary Standards for absorbed dose calibrations in high energy radiation beams from linacs should be explored. As there are neither Standard Laboratories nor SSDL available in our country, we look forward to keep EC as Local Standard for hospital chamber calibrations. We are also participating in the IAEA mailed TLD intercomparison programme for quality audit of existing status of radiation dosimetry in high energy linac beams. The performance of EC has to be confirmed with cobalt-60 beams by a separate study, as linacs are susceptible for minor

  13. Calibration of area monitors for neutrons used in clinical linear accelerators; Calibracao de monitores de area para neutrons usados em aceleradores lineares clinicos

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, Ana Paula; Pereira, Walsan Wagner; Patrao, Karla C. de Souza; Fonseca, Evaldo S. da, E-mail: asalgado@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Batista, Delano V.S. [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This work demonstrates the complexity and the necessary cares for the realization of measurements of neutron fields in rooms for radiotherapy treatment containing clinical accelerators. The acquaintance of the technical characteristics of the monitors and the periodic calibration are actions and fundamental procedures to guarantee traceability and the reliability of measurements

  14. Superconducting linear accelerator system for NSC

    Indian Academy of Sciences (India)

    P N Prakash; T S Datta; B P Ajith Kumar; J Antony; P Barua; J Chacko; A Choudhury; G K Chadhari; S Ghosh; S Kar; S A Krishnan; Manoj Kumar; Rajesh Kumar; A Mandal; D S Mathuria; R S Meena; R Mehta; K K Mistri; A Pandey; M V Suresh Babu; B K Sahu; A Sarkar; S S K Sonti; A Rai; S Venkatramanan; J Zacharias; R K Bhowmik; A Roy

    2002-11-01

    This paper reports the construction of a superconducting linear accelerator as a booster to the 15 UD Pelletron accelerator at Nuclear Science Centre, New Delhi. The LINAC will use superconducting niobium quarter wave resonators as the accelerating element. Construction of the linear accelerator has progressed sufficiently. Details of the entire accelerator system including the cryogenics facility, RF electronics development, facilities for fabricating niobium resonators indigenously, and present status of the project are presented.

  15. Terahertz-driven linear electron acceleration

    CERN Document Server

    Nanni, Emilio Alessandro; Ravi, Koustuban; Fallahi, Arya; Moriena, Gustavo; Miller, R J Dwayne; Kärtner, Franz X

    2014-01-01

    The cost, size and availability of electron accelerators is dominated by the achievable accelerating gradient. Conventional high-brightness radio-frequency (RF) accelerating structures operate with 30-50 MeV/m gradients. Electron accelerators driven with optical or infrared sources have demonstrated accelerating gradients orders of magnitude above that achievable with conventional RF structures. However, laser-driven electron accelerators require intense sources and suffer from low bunch charge, sub-micron tolerances and sub-femtosecond timing requirements due to the short wavelength of operation. Here, we demonstrate the first linear acceleration of electrons with keV energy gain using optically-generated terahertz (THz) pulses. THz-driven accelerating structures enable high-gradient electron accelerators with simple accelerating structures, high repetition rates and significant charge per bunch. Increasing the operational frequency of accelerators into the THz band allows for greatly increased accelerating ...

  16. Combined generating-accelerating buncher for compact linear accelerators

    Science.gov (United States)

    Savin, E. A.; Matsievskiy, S. V.; Sobenin, N. P.; Sokolov, I. D.; Zavadtsev, A. A.

    2016-09-01

    Described in the previous article [1] method of the power extraction from the modulated electron beam has been applied to the compact standing wave electron linear accelerator feeding system, which doesnt require any connection waveguides between the power source and the accelerator itself [2]. Generating and accelerating bunches meet in the hybrid accelerating cell operating at TM020 mode, thus the accelerating module is placed on the axis of the generating module, which consists from the pulsed high voltage electron sources and electrons dumps. This combination makes the accelerator very compact in size which is very valuable for the modern applications such as portable inspection sources. Simulations and geometry cold tests are presented.

  17. Abstract Acceleration of General Linear Loops

    OpenAIRE

    2014-01-01

    International audience; We present abstract acceleration techniques for computing loop invariants for numerical programs with linear assignments and conditionals. Whereas abstract interpretation techniques typically over-approximate the set of reachable states iteratively, abstract acceleration captures the effect of the loop with a single, non-iterative transfer function applied to the initial states at the loop head. In contrast to previous acceleration techniques, our approach applies to a...

  18. Clinic based transfer of the N{sub D,w}{sup 6{sup 0Co}} calibration coefficient using a linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Rahman, W.; Evans, M. D. C.; Serre, L.; McCaffrey, J. P.; Podgorsak, E. B.; Seuntjens, J. P. [Department of Medical Physics, McGill University Health Centre, 1650 Avenue Cedar, Montreal, Quebec H3G 1A4 (Canada); Windsor Regional Cancer Center, 2220 Kildre Road, Windsor, Ontario N8W 2X3 (Canada); Ionizing Radiation Standards, National Research Council of Canada, Ottawa, Ontario K1A 0R6 (Canada); Department of Medical Physics, McGill University Health Centre, 1650 Avenue Cedar, Montreal, Quebec H3G 1A4 (Canada)

    2009-03-15

    Ionization chambers used for reference dosimetry require a local secondary standard ionization chamber with a {sup 60}Co absorbed dose to water calibration coefficient N{sub D,w}{sup 6{sup 0Co}} traceable to a national primary standards dosimetry laboratory or an accredited secondary dosimetry calibration laboratory. Clinic based (in-house) transfer of this coefficient to tertiary reference ionization chambers has traditionally been accomplished with chamber cross calibration in water using a {sup 60}Co beam; however, access to {sup 60}Co teletherapy machines has become increasingly limited for clinic based physicists. In this work, the accuracy of alternative methods of transferring the N{sub D,w}{sup 6{sup 0Co}} calibration coefficient using 6 and 18 MV photon beams from a linear accelerator in lieu of {sup 60}Co has been investigated for five different setups and four commonly used chamber types.

  19. Triplet Focusing for Recirculating Linear Muon Accelerators

    CERN Document Server

    Keil, Eberhard

    2001-01-01

    Focusing by symmetrical triplets is studied for the linear accelerator lattices in recirculating muon accelerators with several passes where the ratio of final to initial muon energy is about four. Triplet and FODO lattices are compared. At similar acceptance, triplet lattices have straight sections for the RF cavities that are about twice as long as in FODO lat-tices. For the same energy gain, the total lengths of the linear accelerators with triplet lattices are about the same as of those with FODO lattices.

  20. Distributed coupling high efficiency linear accelerator

    Science.gov (United States)

    Tantawi, Sami G.; Neilson, Jeffrey

    2016-07-19

    A microwave circuit for a linear accelerator includes multiple monolithic metallic cell plates stacked upon each other so that the beam axis passes vertically through a central acceleration cavity of each plate. Each plate has a directional coupler with coupling arms. A first coupling slot couples the directional coupler to an adjacent directional coupler of an adjacent cell plate, and a second coupling slot couples the directional coupler to the central acceleration cavity. Each directional coupler also has an iris protrusion spaced from corners joining the arms, a convex rounded corner at a first corner joining the arms, and a corner protrusion at a second corner joining the arms.

  1. Linear induction accelerator for heavy ions

    Energy Technology Data Exchange (ETDEWEB)

    Keefe, D.

    1976-09-01

    There is considerable recent interest in the use of high energy (..gamma.. = 1.1), heavy (A greater than or equal to 100) ions to irradiate deuterium--tritium pellets in a reactor vessel to constitute a power source at the level of 1 GW or more. Various accelerator configurations involving storage rings have been suggested. A discussion is given of how the technology of Linear Induction Accelerators--well known to be matched to high current and short pulse length--may offer significant advantages for this application.

  2. Accelerating Dense Linear Algebra on the GPU

    DEFF Research Database (Denmark)

    Sørensen, Hans Henrik Brandenborg

    and matrix-vector operations on GPUs. Such operations form the backbone of level 1 and level 2 routines in the Basic Linear Algebra Subroutines (BLAS) library and are therefore of great importance in many scientific applications. The target hardware is the most recent NVIDIA Tesla 20-series (Fermi......GPUs have already become an integral part of high performance scientific computing, since they offer dedicated parallel hardware that can potentially accelerate the execution of many scientific applications. In this talk, I will consider the automatic performance acceleration of dense vector...

  3. Emittance Growth in Linear Induction Accelerators

    OpenAIRE

    Ekdahl, Carl

    2017-01-01

    The Dual-Axis Radiographic Hydrotest (DARHT) facility uses bremsstrahlung radiation source spots produced by the focused electron beams from two linear induction accelerators (LIAs) to radiograph large hydrodynamic experiments driven by high explosives. Radiographic resolution is determined by the size of the source spot, and beam emittance is the ultimate limitation to spot size. Some of the possible causes for the emittance growth in the DARHT LIA have been investigated using particle-in-ce...

  4. Seventh International Accelerator School for Linear Colliders

    CERN Multimedia

    Organizers of the Seventh International Accelerator School for Linear Colliders

    2012-01-01

    We are pleased to announce the Seventh International Accelerator School for Linear Colliders. This school is a continuation of the series of schools which began six years ago.  The first school was held in 2006 in Sokendai, Japan, the second in 2007 in Erice, Italy, the third in 2008 in Oakbrook Hills, USA, the fourth in 2009 in Huairou, China, the fifth in 2010 in Villars-sur-Ollon, Switzerland, and the sixth in 2011 in Pacific Grove, USA.   The school is organized by the International Linear Collider (ILC) Global Design Effort (GDE), the Compact Linear Collider (CLIC) and the International Committee for Future Accelerators (ICFA) Beam Dynamics Panel. The school this year will take place at the Radisson Blu Hotel, Indore, India from November 27 to December 8, 2012. It is hosted by the Raja Ramanna Center for Advanced Technology (RRCAT) and sponsored by a number of funding agencies and institutions around the world including the U.S. Department of Energy (DOE), the U.S. National Science...

  5. Characterization of the primary source of electrons in linear accelerators in clinical use; Caracterizacion de la fuente primaria de electrones en aceleradores lineales de uso clinico

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Extremera, M.; Gonzalez Infantes, W.; Lallena rojo, A. M.; Anguiano Millan, M.

    2013-07-01

    Monte Carlo simulation is currently considered the most accurate method for calculations of doses due to electrons. The objective of the work is the characterization of the primary source of electrons from an accelerator of clinical use with Monte Carlo simulation, in order to build a model of sources involving a substantial saving of time of calculation in the simulation of treatment. (Author)

  6. Acceleration in Linear and Circular Motion

    Science.gov (United States)

    Kellington, S. H.; Docherty, W.

    1975-01-01

    Describes the construction of a simple accelerometer and explains its use in demonstrating acceleration, deceleration, constant speed, measurement of acceleration, acceleration and the inclined plane and angular and radial acceleration. (GS)

  7. CULA: hybrid GPU accelerated linear algebra routines

    Science.gov (United States)

    Humphrey, John R.; Price, Daniel K.; Spagnoli, Kyle E.; Paolini, Aaron L.; Kelmelis, Eric J.

    2010-04-01

    The modern graphics processing unit (GPU) found in many standard personal computers is a highly parallel math processor capable of nearly 1 TFLOPS peak throughput at a cost similar to a high-end CPU and an excellent FLOPS/watt ratio. High-level linear algebra operations are computationally intense, often requiring O(N3) operations and would seem a natural fit for the processing power of the GPU. Our work is on CULA, a GPU accelerated implementation of linear algebra routines. We present results from factorizations such as LU decomposition, singular value decomposition and QR decomposition along with applications like system solution and least squares. The GPU execution model featured by NVIDIA GPUs based on CUDA demands very strong parallelism, requiring between hundreds and thousands of simultaneous operations to achieve high performance. Some constructs from linear algebra map extremely well to the GPU and others map poorly. CPUs, on the other hand, do well at smaller order parallelism and perform acceptably during low-parallelism code segments. Our work addresses this via hybrid a processing model, in which the CPU and GPU work simultaneously to produce results. In many cases, this is accomplished by allowing each platform to do the work it performs most naturally.

  8. Clinical analysis of linear accelerator radiosurgery for 42 cases with trigeminal neuralgia%X刀治疗三叉神经痛42例临床分析

    Institute of Scientific and Technical Information of China (English)

    陈苏; 王如密; 王守森

    2008-01-01

    Objective To study the treatment effect of linear accelerator radiosurgery (X knife) on trigeminal neuralgia and the complications. Methods Follow-up was conducted in 42 cases of trigeminal neuralgia treated with linear accelerator radiosurgery in our department, and their complications and degree of pain relief were recorded. Results Outcomes were excellent in 14 (33.3%), good in 22 (52.4%), effective in 4 (9.5%) and poor in 2 (4.8%). The mean time of pain relief was 2.1 months. Seven (16.7%) cases experienced increased facial paresthesia. Conclusion Linear accelerator radiosurgery is a precise and effective treatment for trigeminal neuralgia.%目的 探讨直线加速器放射外科(X 刀)治疗三叉神经痛的疗效及其并发症.方法 回顾性分析我科收治的42例三叉神经痛患者的临床资料,均采用X刀治疗并随访疼痛缓解情况和并发症.结果 本组治疗效果为治愈14例(33.3%).显效22例(52.4%),有效4例(9.5%),无效2例(4.8%).疼痛缓解出现时间平均在2.1月之后.7例(16.7%)术后出现面部麻木.结论 X刀是一种精确而有效的治疗三叉神经痛的方法.

  9. Emittance growth in linear induction accelerators

    CERN Document Server

    Ekdahl, C A; Schulze, M E; Carlson, C A; Frayer, D K; Mostrum, C; Thoma, C H

    2014-01-01

    The Dual-Axis Radiographic Hydrotest (DARHT) facility uses bremsstrahlung radiation source spots produced by the focused electron beams from two linear induction accelerators (LIAs) to radiograph large hydrodynamic experiments driven by high explosives. Radiographic resolution is determined by the size of the source spot, and beam emittance is the ultimate limitation to spot size. On the DARHT Axis-II LIA we measure an emittance higher than predicted by theoretical simulations, and even though this axis produces sub-millimeter source spots, we are exploring ways to improve the emittance. Some of the possible causes for the discrepancy have been investigated using particle-in-cell (PIC) codes, although most of these are discounted based on beam measurements. The most likely source of emittance growth is a mismatch of the beam to the magnetic transport, which can cause beam halo.

  10. Evaluation of the environmental equivalent dose rate using area monitors for neutrons in clinical linear accelerators; Avaliacao da taxa de equivalente de dose ambiente utilizando monitores de area para neutrons em aceleradores lineares clinicos

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, Ana Paula; Pereira, Walsan Wagner; Patrao, Karla C. de Souza; Fonseca, Evaldo S. da, E-mail: asalgado@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Batista, Delano V.S. [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The Neutron Laboratory of the Radioprotection and Dosimetry Institute - IRD/CNEN, Rio de Janeiro, Brazil, initiated studies on the process of calibration of neutron area monitors and the results of the measurements performed at radiotherapy treatment rooms, containing clinical accelerators

  11. Luminosity Limitations in Linear Colliders Based on Plasma Acceleration

    CERN Document Server

    Lebedev, Valeri; Nagaitsev, Sergei

    2016-01-01

    Particle acceleration in plasma creates a possibility of exceptionally high accelerating gradients and appears as a very attractive option for future linear electron-positron and/or photon-photon colliders. These high accelerating gradients were already demonstrated in a number of experiments. However, a linear collider requires exceptionally high beam brightness which still needs to be demonstrated. In this article we discuss major phenomena which limit the beam brightness of accelerated beam and, consequently, the collider luminosity.

  12. Multi-beam linear accelerator EVT

    Energy Technology Data Exchange (ETDEWEB)

    Teryaev, Vladimir E., E-mail: vladimir_teryaev@mail.ru [Omega-P, Inc., New Haven, CT 06510 (United States); Kazakov, Sergey Yu. [Fermilab, Batavia, IL 60510 (United States); Hirshfield, Jay L. [Omega-P, Inc., New Haven, CT 06510 (United States); Yale University, New Haven, CT 06511 (United States)

    2016-09-01

    A novel electron multi-beam accelerator is presented. The accelerator, short-named EVT (Electron Voltage Transformer) belongs to the class of two-beam accelerators. It combines an RF generator and essentially an accelerator within the same vacuum envelope. Drive beam-lets and an accelerated beam are modulated in RF modulators and then bunches pass into an accelerating structure, comprising uncoupled with each other and inductive tuned cavities, where the energy transfer from the drive beams to the accelerated beam occurs. A phasing of bunches is solved by choice correspond distances between gaps of the adjacent cavities. Preliminary results of numerical simulations and the initial specification of EVT operating in S-band, with a 60 kV gun and generating a 2.7 A, 1.1 MV beam at its output is presented. A relatively high efficiency of 67% and high design average power suggest that EVT can find its use in industrial applications.

  13. Vacuum systems of linear accelerators of the NICA injection complex

    Science.gov (United States)

    Kosachev, V. V.; Bazanov, A. M.; Butenko, A. V.; Galimov, A. R.; Nesterov, A. V.; Pivin, R. V.; Smirnov, A. V.

    2016-12-01

    The NICA project, which includes several accelerators of charged particles, is under construction in the Laboratory of High Energy Physics, Joint Institute for Nuclear Research (JINR), Dubna. Obtaining the required vacuum conditions is one of the key points in implementing the project, because reaching the required ion lifetime at all stages of particle acceleration is what determines the effective luminosity of the experiments in the long run. Currently, modernization of the vacuum system of the injection complex of the LU-20 linear accelerator of light ions, one of oldest accelerators in the JINR, is being carried out and the new HILAC linear accelerator for the acceleration of gold ions in the collider mode of the NICA complex is being installed. At the end parts of the linear accelerators, the residual gas pressure must be approximately 10-5 Pa, which is determined by the maximum amplitude of the RF electric field used for the acceleration of ions.

  14. Consequences of removing the flattening filter from linear accelerators in generating high dose rate photon beams for clinical applications: A Monte Carlo study verified by measurement

    Energy Technology Data Exchange (ETDEWEB)

    Ishmael Parsai, E. [Department of Radiation Oncology, University of Toledo, 3000 Arlington Avenue, Toledo, OH 43614 (United States)]. E-mail: Ishmael.parsai@utoledo.edu; Pearson, David [Department of Radiation Oncology, University of Toledo, 3000 Arlington Avenue, Toledo, OH 43614 (United States); Department of Physics and Astronomy, University of Toledo, 3000 Arlington Avenue, Toledo, OH 43614 (United States); Kvale, Thomas [Department of Physics and Astronomy, University of Toledo, 3000 Arlington Avenue, Toledo, OH 43614 (United States)

    2007-08-15

    An Elekta SL-25 medical linear accelerator (Elekta Oncology Systems, Crawley, UK) has been modelled using Monte Carlo simulations with the photon flattening filter removed. It is hypothesized that intensity modulated radiation therapy (IMRT) treatments may be carried out after the removal of this component despite it's criticality to standard treatments. Measurements using a scanning water phantom were also performed after the flattening filter had been removed. Both simulated and measured beam profiles showed that dose on the central axis increased, with the Monte Carlo simulations showing an increase by a factor of 2.35 for 6 MV and 4.18 for 10 MV beams. A further consequence of removing the flattening filter was the softening of the photon energy spectrum leading to a steeper reduction in dose at depths greater than the depth of maximum dose. A comparison of the points at the field edge showed that dose was reduced at these points by as much as 5.8% for larger fields. In conclusion, the greater photon fluence is expected to result in shorter treatment times, while the reduction in dose outside of the treatment field is strongly suggestive of more accurate dose delivery to the target.

  15. Self-shielded electron linear accelerators designed for radiation technologies

    Science.gov (United States)

    Belugin, V. M.; Rozanov, N. E.; Pirozhenko, V. M.

    2009-09-01

    This paper describes self-shielded high-intensity electron linear accelerators designed for radiation technologies. The specific property of the accelerators is that they do not apply an external magnetic field; acceleration and focusing of electron beams are performed by radio-frequency fields in the accelerating structures. The main characteristics of the accelerators are high current and beam power, but also reliable operation and a long service life. To obtain these characteristics, a number of problems have been solved, including a particular optimization of the accelerator components and the application of a variety of specific means. The paper describes features of the electron beam dynamics, accelerating structure, and radio-frequency power supply. Several compact self-shielded accelerators for radiation sterilization and x-ray cargo inspection have been created. The introduced methods made it possible to obtain a high intensity of the electron beam and good performance of the accelerators.

  16. Wakefields and Instabilities in Linear Accelerators

    CERN Document Server

    Ferrario, M; Palumbo, L

    2014-01-01

    When a charged particle travels across the vacuum chamber of an accelerator, it induces electromagnetic fields, which are left mainly behind the generating particle. These electromagnetic fields act back on the beam and influence its motion. Such an interaction of the beam with its surro undings results in beam energy losses, alters the shape of the bunches, and shifts the betatron and synchrotron frequencies. At high beam current the fields can even lead to instabilities, thus limiting the performance of the accelerator in terms of beam quality and current intensity. We discuss in this lecture the general features of the electromagnetic fields, introducing the concepts of wakefields and giving a few simple examples in cylindrical geometry. We then show the effect of the wakefields on the dynamics of a beam in a linac, dealing in particular with the beam breakup instability and how to cure it.

  17. Application of local area networks to accelerator control systems at the Stanford Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Fox, J.D.; Linstadt, E.; Melen, R.

    1983-03-01

    The history and current status of SLAC's SDLC networks for distributed accelerator control systems are discussed. These local area networks have been used for instrumentation and control of the linear accelerator. Network topologies, protocols, physical links, and logical interconnections are discussed for specific applications in distributed data acquisition and control system, computer networks and accelerator operations.

  18. [The security system of SIEMENS digital linear accelerator].

    Science.gov (United States)

    Wang, Jianping

    2013-03-01

    The security system plays an important role to protect the safety of patients and equipment in radiotherapy. The principle and structure of three kinds of security system of the Siemens digital linear accelerator were analyzed with some examples.

  19. Detection of linear ego-acceleration from optic flow.

    Science.gov (United States)

    Festl, Freya; Recktenwald, Fabian; Yuan, Chunrong; Mallot, Hanspeter A

    2012-07-20

    Human observers are able to estimate various ego-motion parameters from optic flow, including rotation, translational heading, time-to-collision (TTC), time-to-passage (TTP), etc. The perception of linear ego-acceleration or deceleration, i.e., changes of translational velocity, is less well understood. While time-to-passage experiments indicate that ego-acceleration is neglected, subjects are able to keep their (perceived) speed constant under changing conditions, indicating that some sense of ego-acceleration or velocity change must be present. In this paper, we analyze the relation of ego-acceleration estimates and geometrical parameters of the environment using simulated flights through cylindrical and conic (narrowing or widening) corridors. Theoretical analysis shows that a logarithmic ego-acceleration parameter, called the acceleration rate ρ, can be calculated from retinal acceleration measurements. This parameter is independent of the geometrical layout of the scene; if veridical ego-motion is known at some instant in time, acceleration rate allows updating of ego-motion without further depth-velocity calibration. Results indicate, however, that subjects systematically confuse ego-acceleration with corridor narrowing and ego-deceleration with corridor widening, while veridically judging ego-acceleration in straight corridors. We conclude that judgments of ego-acceleration are based on first-order retinal flow and do not make use of acceleration rate or retinal acceleration.

  20. A beam-matching concept for medical linear accelerators

    DEFF Research Database (Denmark)

    Sjöström, David; Bjelkengren, Ulf; Ottosson, Wiviann

    2009-01-01

    The flexibility in radiotherapy can be improved if a patient can be moved between any one of the department's medical linear accelerators without the need to change anything in the patient's treatment plan. For this to be possible, the dosimetric characteristics of the various accelerators must b...

  1. Evaluation of neutron doses beyond of primary shielding of rooms housing clinical linear accelerators; Avaliacao das doses de neutrons alem das barreiras primarias de salas que abrigam aceleradores lineares clinicos

    Energy Technology Data Exchange (ETDEWEB)

    Rezende, Gabriel Fonseca da Silva

    2011-07-01

    The growing need to build radiotherapy rooms in places with lack of available space leads to the necessity of unconventional solutions for the shielding projects. In most cases, adding metals to the primary barriers is the best way to shield the rooms properly. However, when photons with energies equal to or great than 10 MeV interact with nuclei of materials with high atomic number, neutrons are ejected and can result in a problem of radioprotection both inside and outside the room. Currently, the only empirical formula existing in the literature to assess the dose equivalent due to neutrons beyond the laminated barriers works only under very specific conditions, and a validation of this formula had not yet been done. In this work, the Monte Carlo code MCNPX was used to verify the validity of the above formula for cases of primary barriers containing lead or iron sheets in rooms that house linear accelerators with 10, 15 and 18 MV. Moreover, such a code was used to evaluate the coefficient of neutron production and tenth-value layer for neutrons in concrete, both parameters that directly influence the equation studied. The study results showed that over 90% of the values compared between the formula and the simulations present discrepancies above 100%, which led to conclude that the formula from the literature produces values that do not match the reality. In addition, there were inconsistencies in the parameters that make up the formula, leading to a need to review this formula in order to build a new model that will better represent the real case. (author)

  2. Characteristics of induced activity from medical linear accelerators.

    Science.gov (United States)

    Wang, Yi Zhen; Evans, Michael D C; Podgorsak, Ervin B

    2005-09-01

    A study of the induced activity in a medical linear accelerator (linac) room was carried out on several linac installations. Higher beam energy, higher dose rate, and larger field size generally result in higher activation levels at a given point of interest, while the use of multileaf collimators (MLC) can also increase the activation level at the isocenter. Both theoretical and experimental studies reveal that the activation level in the morning before any clinical work increases from Monday to Saturday and then decreases during the weekend. This weekly activation picture keeps stable from one week to another during standard clinical operation of the linac. An effective half-life for a given point in the treatment room can be determined from the measured or calculated activity decay curves. The effective half-life for points inside the treatment field is longer than that for points outside of the field in the patient plane, while a larger field and longer irradiation time can also make the effective half-life longer. The activation level reaches its practical saturation value after a 30 min continuous irradiation, corresponding to 12 000 MU at a "dose rate" of 400 MU/min. A "dose" of 300 MU was given 20 times in 15 min intervals to determine the trends in the activation level in a typical clinical mode. As well, a long-term (85 h over a long weekend) decay curve was measured to evaluate the long-term decay of room activation after a typical day of clinical linac use. A mathematical model for the activation level at the isocenter has been established and shown to be useful in explaining and predicting the induced activity levels for typical clinical and experimental conditions. The activation level for a 22 MeV electron beam was also measured and the result shows it is essentially negligible.

  3. CHEBYSHEV ACCELERATION TECHNIQUE FOR SOLVING FUZZY LINEAR SYSTEM

    Directory of Open Access Journals (Sweden)

    S.H. Nasseri

    2009-10-01

    Full Text Available In this paper, Chebyshev acceleration technique is used to solve the fuzzy linear system (FLS. This method is discussed in details and followed by summary of some other acceleration techniques. Moreover, we show that in some situations that the methods such as Jacobi, Gauss-Sidel, SOR and conjugate gradient is divergent, our proposed method is applicable and the acquired results are illustrated by some numerical examples.

  4. Linear to non linear analysis for positron acceleration in plasma hollow channel wakefields

    Science.gov (United States)

    Amorim, Ligia Diana; An, Weiming; Mori, Warren B.; Vieira, Jorge

    2016-10-01

    Plasma wakefield accelerators are promising candidates for future generation compact accelerators. The standard regime of operation, non-linear or blowout regime, is reached when a particle bunch space charge or laser pulse ponderomotive force radially expels plasma electrons forming a bucket of ions that defocus positron bunches, thus preventing their acceleration. To avoid defocusing, hollow plasma channels have been considered. The corresponding wakefields have been examined in the linear and non-linear excitation regimes for electrons. It is therefore important to extend the theory for positron acceleration, particularly in the nonlinear regime where the wakefields strongly differ. In this work we explore the wakefield structure, examine the differences between the electron and positron beam cases, and explore positron acceleration in nonlinear regimes. We support our findings with multi-dimensional particle-in-cell simulations performed with OSIRIS and quasi-3D and QuickPIC.

  5. Kinematics and hydrodynamics of linear acceleration in eels, Anguilla rostrata.

    Science.gov (United States)

    Tytell, Eric D

    2004-12-22

    The kinematics and hydrodynamics of routine linear accelerations were studied in American eels, Anguilla rostrata, using high-speed video and particle image velocimetry. Eels were examined both during steady swimming at speeds from 0.6 to 1.9 body lengths (L) per second and during accelerations from -1.4 to 1.3 L s(-2). Multiple regression of the acceleration and steady swimming speed on the body kinematics suggests that eels primarily change their tail-tip velocity during acceleration. By contrast, the best predictor of steady swimming speed is body wave speed, keeping tail-tip velocity an approximately constant fraction of the swimming velocity. Thus, during steady swimming, Strouhal number does not vary with speed, remaining close to 0.32, but during acceleration, it deviates from the steady value. The kinematic changes during acceleration are indicated hydrodynamically by axial fluid momentum in the wake. During steady swimming, the wake consists of lateral jets of fluid and has minimal net axial momentum, which reflects a balance between thrust and drag. During acceleration, those jets rotate to point downstream, adding axial momentum to the fluid. The amount of added momentum correlates with the acceleration, but is greater than the necessary inertial force by 2.8+/-0.6 times, indicating a substantial acceleration reaction.

  6. Staging optics considerations for a plasma wakefield acceleration linear collider

    Energy Technology Data Exchange (ETDEWEB)

    Lindstrøm, C.A., E-mail: c.a.lindstrom@fys.uio.no [Department of Physics, University of Oslo, Oslo 0316 (Norway); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Adli, E. [Department of Physics, University of Oslo, Oslo 0316 (Norway); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Allen, J.M.; Delahaye, J.P.; Hogan, M.J. [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Joshi, C. [Department of Electrical Engineering, UCLA, Los Angeles, CA 90095 (United States); Muggli, P. [Max Planck Institute for Physics, 80805 Munich (Germany); Raubenheimer, T.O.; Yakimenko, V. [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States)

    2016-09-01

    Plasma wakefield acceleration offers acceleration gradients of several GeV/m, ideal for a next-generation linear collider. The beam optics requirements between plasma cells include injection and extraction of drive beams, matching the main beam beta functions into the next cell, canceling dispersion as well as constraining bunch lengthening and chromaticity. To maintain a high effective acceleration gradient, this must be accomplished in the shortest distance possible. A working example is presented, using novel methods to correct chromaticity, as well as scaling laws for a high energy regime.

  7. The MRI-Linear Accelerator Consortium: Evidence-Based Clinical Introduction of an Innovation in Radiation Oncology Connecting Researchers, Methodology, Data Collection, Quality Assurance, and Technical Development

    Science.gov (United States)

    Kerkmeijer, Linda G. W.; Fuller, Clifton D.; Verkooijen, Helena M.; Verheij, Marcel; Choudhury, Ananya; Harrington, Kevin J.; Schultz, Chris; Sahgal, Arjun; Frank, Steven J.; Goldwein, Joel; Brown, Kevin J.; Minsky, Bruce D.; van Vulpen, Marco

    2016-01-01

    An international research consortium has been formed to facilitate evidence-based introduction of MR-guided radiotherapy (MR-linac) and to address how the MR-linac could be used to achieve an optimized radiation treatment approach to improve patients’ survival, local, and regional tumor control and quality of life. The present paper describes the organizational structure of the clinical part of the MR-linac consortium. Furthermore, it elucidates why collaboration on this large project is necessary, and how a central data registry program will be implemented. PMID:27790408

  8. Spin dynamics in storage rings and linear accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Irwin, J.

    1994-04-01

    The purpose of these lectures is to survey the subject of spin dynamics in accelerators: to give a sense of the underlying physics, the typical analytic and numeric methods used, and an overview of results achieved. Consideration will be limited to electrons and protons. Examples of experimental and theoretical results in both linear and circular machines are included.

  9. Annotated bibliography on high-intensity linear accelerators. [240 citations

    Energy Technology Data Exchange (ETDEWEB)

    Jameson, R.A.; Roybal, E.U.

    1978-01-01

    A technical bibliography covering subjects important to the design of high-intensity beam transport systems and linear accelerators is presented. Space charge and emittance growth are stressed. Subject and author concordances provide cross-reference to detailed citations, which include an abstract and notes on the material. The bibliography resides in a computer database that can be searched for key words and phrases.

  10. linear accelerator simulation framework with placet and guinea-pig

    CERN Document Server

    Snuverink, Jochem; CERN. Geneva. ATS Department

    2016-01-01

    Many good tracking tools are available for simulations for linear accelerators. However, several simple tasks need to be performed repeatedly, like lattice definitions, beam setup, output storage, etc. In addition, complex simulations can become unmanageable quite easily. A high level layer would therefore be beneficial. We propose LinSim, a linear accelerator framework with the codes PLACET and GUINEA-PIG. It provides a documented well-debugged high level layer of functionality. Users only need to provide the input settings and essential code and / or use some of the many implemented imperfections and algorithms. It can be especially useful for first-time users. Currently the following accelerators are implemented: ATF2, ILC, CLIC and FACET. This note is the comprehensive manual, discusses the framework design and shows its strength in some condensed examples.

  11. Challenges in the design of linear accelerator tunnels and services

    CERN Document Server

    Osborne, John

    2008-01-01

    Studies are well underway for the next generation of linear accelerators. The International Linear Collider (ILC) is working towards a maximum collision energy of 1 TeV and the Compact Linear Collider (CLIC) even higher at 3 TeV. Although the accelerating technologies are very different, many similarities can be found between the two projects from a civil engineering and technical services point of view. Both projects would require a site of approximately 50 km in length with stable geological conditions. CERN has been selected as one of the sample sites for the preliminary studies. The aim of this paper is to present the key challenges in the design of civil engineering and technical services such as cooling, ventilation and electricity that need to be overcome to realise such large scale projects in the future.

  12. Acquiring beam data for a flattening-filter free linear accelerator using organic scintillators

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Behrens, C.F.; Hoffmann, L.;

    2013-01-01

    -resolved dosimetry on a highly detailed level. In this study, we present beam data for a Varian TrueBeam linear accelerator, which is capable of delivering flattening-filter free (FFF1) clinical X-ray beams. The beam data have been acquired using an in-house developed dosimetry system based on fibre-coupled organic...

  13. 9th International Accelerator School for Linear Colliders

    CERN Document Server

    2015-01-01

    This school is a continuation of the series of schools that began nine years ago: Japan 2006, Italy 2007, United States 2008, China 2009, Switzerland 2010, United States 2011, India 2012 and Turkey 2013. Based on needs from the accelerator community, the Linear Collider Collaboration (LCC) and ICFA Beam Dynamics Panel are organising the Ninth International Accelerator School for Linear Colliders. The school will present instruction in TeV-scale linear colliders including the ILC, CLIC and other advanced accelerators. An important change of this year’s school from previous LC schools is that it will also include the free electron laser (FEL), a natural extension for applications of the ILC/CLIC technology. The school is offered to graduate students, postdoctoral fellows and junior researchers from around the world. We welcome applications from physicists who are considering changing to a career in accelerator physics and technology. This school adopts an in depth approach. A selective course on the FEL has b...

  14. Lorentz-Dirac force from QED for linear acceleration

    Science.gov (United States)

    Higuchi, Atsushi; Martin, Giles D.

    2004-10-01

    We investigate the motion of a wave packet of a charged scalar particle linearly accelerated by a static potential in quantum electrodynamics. We calculate the expectation value of the position of the charged particle after the acceleration to first order in the fine structure constant in the ℏ→0 limit. We find that the change in the expectation value of the position (the position shift) due to radiation reaction agrees exactly with the result obtained using the Lorentz-Dirac force in classical electrodynamics. We also point out that the one-loop correction to the potential may contribute to the position change in this limit.

  15. Beam dynamics in a long-pulse linear induction accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Carl [Los Alamos National Laboratory; Abeyta, Epifanio O [Los Alamos National Laboratory; Aragon, Paul [Los Alamos National Laboratory; Archuleta, Rita [Los Alamos National Laboratory; Cook, Gerald [Los Alamos National Laboratory; Dalmas, Dale [Los Alamos National Laboratory; Esquibel, Kevin [Los Alamos National Laboratory; Gallegos, Robert A [Los Alamos National Laboratory; Garnett, Robert [Los Alamos National Laboratory; Harrison, James F [Los Alamos National Laboratory; Johnson, Jeffrey B [Los Alamos National Laboratory; Jacquez, Edward B [Los Alamos National Laboratory; Mc Cuistian, Brian T [Los Alamos National Laboratory; Montoya, Nicholas A [Los Alamos National Laboratory; Nath, Subrato [Los Alamos National Laboratory; Nielsen, Kurt [Los Alamos National Laboratory; Oro, David [Los Alamos National Laboratory; Prichard, Benjamin [Los Alamos National Laboratory; Rose, Chris R [Los Alamos National Laboratory; Sanchez, Manolito [Los Alamos National Laboratory; Schauer, Martin M [Los Alamos National Laboratory; Seitz, Gerald [Los Alamos National Laboratory; Schulze, Martin [Los Alamos National Laboratory; Bender, Howard A [Los Alamos National Laboratory; Broste, William B [Los Alamos National Laboratory; Carlson, Carl A [Los Alamos National Laboratory; Frayer, Daniel K [Los Alamos National Laboratory; Johnson, Douglas E [Los Alamos National Laboratory; Tom, C Y [Los Alamos National Laboratory; Trainham, C [Los Alamos National Laboratory; Williams, John [Los Alamos National Laboratory; Scarpetti, Raymond [LLNL; Genoni, Thomas [VOSS; Hughes, Thomas [VOSS; Toma, Carsten [VOSS

    2010-01-01

    The second axis of the Dual Axis Radiography of Hydrodynamic Testing (DARHT) facility produces up to four radiographs within an interval of 1.6 microseconds. It accomplishes this by slicing four micro-pulses out of a long 1.8-kA, 16.5-MeV electron beam pulse and focusing them onto a bremsstrahlung converter target. The long beam pulse is created by a dispenser cathode diode and accelerated by the unique DARHT Axis-II linear induction accelerator (LIA). Beam motion in the accelerator would be a problem for radiography. High frequency motion, such as from beam breakup instability, would blur the individual spots. Low frequency motion, such as produced by pulsed power variation, would produce spot to spot differences. In this article, we describe these sources of beam motion, and the measures we have taken to minimize it.

  16. Linear accelerator radiosurgery for trigeminal neuralgia: case report

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Hyong Geun [Dongguk University International Hospital, Goyang (Korea, Republic of)

    2006-06-15

    Trigeminal neuralgia is defined as an episodic electrical shock-like sensation in a dermatomal distribution of the trigeminal nerve. When medications fail to control pain, various procedures are used to attempt to control refractory pain. Of available procedures, stereotactic radiosurgery is the least invasive procedure and has been demonstrated to produce significant pain relief with minimal side effects. Recently, linear accelerators were introduced as a tool for radiosurgery of trigeminal neuralgia beneath the already accepted gamma unit. Author have experienced one case with trigeminal neuralgia treated with linear accelerator. The patient was treated with 85 Gy by means of 5 mm collimator directed to trigeminal nerve root entry zone. The patient obtained pain free without medication at 20 days after the procedure and remain pain free at 6 months after the procedure. He didn't experience facial numbness or other side effects.

  17. Rotational total skin electron irradiation with a linear accelerator.

    Science.gov (United States)

    Reynard, Eric P; Evans, Michael D C; Devic, Slobodan; Parker, William; Freeman, Carolyn R; Roberge, David; Podgorsak, Ervin B

    2008-11-03

    The rotational total skin electron irradiation (RTSEI) technique at our institution has undergone several developments over the past few years. Replacement of the formerly used linear accelerator has prompted many modifications to the previous technique. With the current technique, the patient is treated with a single large field while standing on a rotating platform, at a source-to-surface distance of 380 cm. The electron field is produced by a Varian 21EX linear accelerator using the commercially available 6 MeV high dose rate total skin electron mode, along with a custom-built flattening filter. Ionization chambers, radiochromic film, and MOSFET (metal oxide semiconductor field effect transistor) detectors have been used to determine the dosimetric properties of this technique. Measurements investigating the stationary beam properties, the effects of full rotation, and the dose distributions to a humanoid phantom are reported. The current treatment technique and dose regimen are also described.

  18. Organizational cultural survey of the Stanford Linear Accelerator Center

    Energy Technology Data Exchange (ETDEWEB)

    1991-11-01

    At the request of the Department of Energy, an Organizational Survey (OS) was administered at the Stanford Linear Accelerator Center (SLAC). The OS measured employees' opinions on subjects such as organizational culture, communication, commitment, group cohesion, coordination, safety, environmental issues, and job satisfaction. The result of this work was a quantitative measure of the notion of culture at the SLAC site. This report presents these results and discusses their interpretation.

  19. Outcome of cerebral arteriovenous malformations after linear accelerator reirradiation

    Science.gov (United States)

    Moraes, Paulo L.; Dias, Rodrigo S.; Weltman, Eduardo; Giordani, Adelmo J.; Benabou, Salomon; Segreto, Helena R. C.; Segreto, Roberto A.

    2015-01-01

    Background: The aim of this study was to evaluate the clinical outcome of patients undergoing single-dose reirradiation using the Linear Accelerator (LINAC) for brain arteriovenous malformations (AVM). Methods: A retrospective study of 37 patients with brain AVM undergoing LINAC reirradiation between April 2003 and November 2011 was carried out. Patient characteristics, for example, gender, age, use of medications, and comorbidities; disease characteristics, for example, Spetzler–Martin grading system, location, volume, modified Pollock–Flickinger score; and treatment characteristics, for example, embolization, prescription dose, radiation dose–volume curves, and conformity index were analyzed. During the follow-up period, imaging studies were performed to evaluate changes after treatment and AVM cure. Complications, such as edema, rupture of the blood–brain barrier, and radionecrosis were classified as symptomatic and asymptomatic. Results: Twenty-seven patients underwent angiogram after reirradiation and the percentage of angiographic occlusion was 55.5%. In three patients without obliteration, AVM shrinkage made it possible to perform surgical resection with a 2/3 cure rate. A reduction in AVM nidus volume greater than 50% after the first procedure was shown to be the most important predictor of obliteration. Another factor associated with AVM cure was a prescription dose higher than 15.5 Gy in the first radiosurgery. Two patients had permanent neurologic deficits. Factors correlated with complications were the prescription dose and maximum dose in the first procedure. Conclusion: This study suggests that single-dose reirradiation is safe and feasible in partially occluded AVM. Reirradiation may not benefit candidates whose prescribed dose was lower than 15.5 Gy in the first procedure and initial AVM nidus volume did not decrease by more than 50% before reirradiation. PMID:26110078

  20. Outcome of cerebral arteriovenous malformations after linear accelerator reirradiation

    Directory of Open Access Journals (Sweden)

    Paulo L Moraes

    2015-01-01

    Full Text Available Background: The aim of this study was to evaluate the clinical outcome of patients undergoing single-dose reirradiation using the Linear Accelerator (LINAC for brain arteriovenous malformations (AVM. Methods: A retrospective study of 37 patients with brain AVM undergoing LINAC reirradiation between April 2003 and November 2011 was carried out. Patient characteristics, for example, gender, age, use of medications, and comorbidities; disease characteristics, for example, Spetzler-Martin grading system, location, volume, modified Pollock-Flickinger score; and treatment characteristics, for example, embolization, prescription dose, radiation dose-volume curves, and conformity index were analyzed. During the follow-up period, imaging studies were performed to evaluate changes after treatment and AVM cure. Complications, such as edema, rupture of the blood-brain barrier, and radionecrosis were classified as symptomatic and asymptomatic. Results: Twenty-seven patients underwent angiogram after reirradiation and the percentage of angiographic occlusion was 55.5%. In three patients without obliteration, AVM shrinkage made it possible to perform surgical resection with a 2/3 cure rate. A reduction in AVM nidus volume greater than 50% after the first procedure was shown to be the most important predictor of obliteration. Another factor associated with AVM cure was a prescription dose higher than 15.5 Gy in the first radiosurgery. Two patients had permanent neurologic deficits. Factors correlated with complications were the prescription dose and maximum dose in the first procedure. Conclusion: This study suggests that single-dose reirradiation is safe and feasible in partially occluded AVM. Reirradiation may not benefit candidates whose prescribed dose was lower than 15.5 Gy in the first procedure and initial AVM nidus volume did not decrease by more than 50% before reirradiation.

  1. Versatile Low Level RF System For Linear Accelerators

    Science.gov (United States)

    Potter, James M.

    2011-06-01

    The Low Level RF (LLRF) system is the source of all of the rf signals required for an rf linear accelerator. These signals are amplified to drive accelerator and buncher cavities. It can even provide the synchronizing signal for the rf power for a synchrotron. The use of Direct Digital Synthesis (DDS) techniques results in a versatile system that can provide multiple coherent signals at the same or different frequencies with adjustable amplitudes and phase relations. Pulsing the DDS allows rf switching with an essentially infinite on/off ratio. The LLRF system includes a versatile phase detector that allows phase-locking the rf frequency to a cavity at any phase angle over the full 360° range. With the use of stepper motor driven slug tuners multiple cavity resonant frequencies can be phase locked to the rf source frequency. No external phase shifters are required and there is no feedback loop phase setup required. All that is needed is to turn the frequency feedback on. The use of Digital Signal Processing (DSP) allows amplitude and phase control over the entire rf pulse. This paper describes the basic principles of a LLRF system that has been used for both proton accelerators and electron accelerators, including multiple tank accelerators, sub-harmonic and fundamental bunchers, and synchrotrons.

  2. Control system analysis for the perturbed linear accelerator rf system

    CERN Document Server

    Sung Il Kwon

    2002-01-01

    This paper addresses the modeling problem of the linear accelerator RF system in SNS. Klystrons are modeled as linear parameter varying systems. The effect of the high voltage power supply ripple on the klystron output voltage and the output phase is modeled as an additive disturbance. The cavity is modeled as a linear system and the beam current is modeled as the exogenous disturbance. The output uncertainty of the low level RF system which results from the uncertainties in the RF components and cabling is modeled as multiplicative uncertainty. Also, the feedback loop uncertainty and digital signal processing signal conditioning subsystem uncertainties are lumped together and are modeled as multiplicative uncertainty. Finally, the time delays in the loop are modeled as a lumped time delay. For the perturbed open loop system, the closed loop system performance, and stability are analyzed with the PI feedback controller.

  3. Heterogenous Acceleration for Linear Algebra in Multi-coprocessor Environments

    Energy Technology Data Exchange (ETDEWEB)

    Luszczek, Piotr R [ORNL; Tomov, Stanimire Z [ORNL; Dongarra, Jack J [ORNL

    2015-01-01

    We present an efficient and scalable programming model for the development of linear algebra in heterogeneous multi-coprocessor environments. The model incorporates some of the current best design and implementation practices for the heterogeneous acceleration of dense linear algebra (DLA). Examples are given as the basis for solving linear systems' algorithms - the LU, QR, and Cholesky factorizations. To generate the extreme level of parallelism needed for the efficient use of coprocessors, algorithms of interest are redesigned and then split into well-chosen computational tasks. The tasks execution is scheduled over the computational components of a hybrid system of multi-core CPUs and coprocessors using a light-weight runtime system. The use of lightweight runtime systems keeps scheduling overhead low, while enabling the expression of parallelism through otherwise sequential code. This simplifies the development efforts and allows the exploration of the unique strengths of the various hardware components.

  4. Radiation protection in large linear accelerators; Seguranca radiologica de aceleradores lineares de grande porte

    Energy Technology Data Exchange (ETDEWEB)

    Oliva, Jose de Jesus Rivero, E-mail: rivero@con.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Departamento de Engenharia Nuclear; Sousa, Fernando Nuno Carneiro de, E-mail: fernandonunosousa@gmail.com [Aceletron Irradiacao lndustrial, Rio de Janeiro, RJ (Brazil)

    2013-07-01

    The electron linear accelerators can be used in industrial applications that require powerful sources of ionizing radiation. They have the important characteristic of not representing a radiation hazard when the accelerators remain electrically disconnected. With the plant in operation, a high reliability defense in depth reduces the risk of radiological accidents to extremely small levels. It is practically impossible that a person could enter into the radiation bunker with the accelerators connected. Aceletron Irradiacao Industrial, located in Rio de Janeiro, offers services of irradiation by means of two powerful electron linear accelerators, with 15 kW power and 10 MeV electron energy. Despite the high level of existing radiation safety, a simplified risk study is underway to identify possible sequences of radiological accidents. The study is based on the combined application of the event and fault trees techniques. Preliminary results confirm that there is a very small risk of entering into the irradiation bunker with the accelerators in operation, but the risk of an operator entering into the bunker during a process interruption and remaining there without notice after the accelerators were restarted may be considerably larger. Based on these results the Company is considering alternatives to reduce the likelihood of human error of this type that could lead to a radiological accident. The paper describes the defense in depth of the irradiation process in Aceletron Irradiacao Industrial, as well as the models and preliminary results of the ongoing risk analysis, including the additional safety measures which are being evaluated. (author)

  5. Ion acceleration in a scalable MEMS RF-structure for a compact linear accelerator

    CERN Document Server

    Persaud, A; Feinberg, E; Seidl, P A; Waldron, W L; Lal, A; Vinayakumar, K B; Ardanuc, S; Schenkel, T

    2016-01-01

    A new approach for a compact radio-frequency(rf) accelerator structure is presented. The idea is based on the Multiple Electrostatic Quadrupole Array Linear Accelerator (MEQALAC) structure that was first developed in the 1980s. The MEQALAC allowed scaling of rf-structure down to dimensions of centimeters while at the same time allowing for higher beam currents through parallel beamlets. Using micro-electro-mechanical systems (MEMS) for highly scalable fabrication, we reduce the critical dimension to the sub-millimeter regime, while massively scaling up the potential number of parallel beamlets. The technology is based on rf-acceleration components and electrostatic quadrupoles (ESQs) implemented in a silicon wafer based design where each beamlet passes through beam apertures in the wafer. The complete accelerator is then assembled by stacking these wafers. This approach allows fast and cheap batch fabrication of the components and flexibility in system design for different applications. For prototyping these ...

  6. Safety managements of the linear IFMIF/EVEDA prototype accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Hiroki, E-mail: takahashi.hiroki@jaea.go.jp [IFMIF Accelerator Facility Development Group, Directorates of Fusion Energy Research, JAEA (Japan); Maebara, Sunao; Kojima, Toshiyuki; Narita, Takahiro; Tsutsumi, Kazuyoshi [IFMIF Accelerator Facility Development Group, Directorates of Fusion Energy Research, JAEA (Japan); Sakaki, Hironao [Photo Medical Research Center, JAEA (Japan); Suzuki, Hiromitsu [IFMIF Accelerator Facility Development Group, Directorates of Fusion Energy Research, JAEA (Japan); Sugimoto, Masayoshi [Directorates of Fusion Energy Research, JAEA (Japan)

    2014-10-15

    Highlights: •Safety management is needed to secure the personnel safety from high dose rate. •The management of access to the accelerator vault is mainly performed by PPS. •The operation management is needed for safety during Injector and RFQ commissioning. •Pulse Duty Management system is newly developed for Injector commissioning for operation management. •PDM system is useful to reduce the radioactivation of equipment and the radiation exposure during and after beam operation. -- Abstract: On the Linear IFMIF/EVEDA Prototype Accelerator (LIPAc), the validation up to 9 MeV deuteron beam with 125 mA continuous wave is planned in Rokkasho, Aomori, Japan. Since the deuteron beam power exceeds 1 MW, safety issue related to γ-ray and neutron production is critical. To establish the safety management indispensable to reduce radiation exposure for personnel and activation of accelerator equipment, Personnel Protection System (PPS) of LIPAc control system, which works together with Radiation Monitoring System and Access Control System, was developed for LIPAc. The management of access to the accelerator vault by PPS and the beam duty management of PPS are presented in details.

  7. The general RF tuning for IH-DTL linear accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Y.R. [Key State Laboratory of Nuclear Physics and Technology, Peking University (China)], E-mail: yrlu@pku.edu.cn; Ratzinger, U. [Institute of Applied Physics, Frankfurt University (Germany); Schlitt, B. [Gesellschaft fuer Schwerionenforschung, mbH, Darmstadt (Germany); Tiede, R. [Institute of Applied Physics, Frankfurt University (Germany)

    2007-11-21

    The RF tuning is the most important research for achieving the resonant frequency and the flatness of electric field distributions along the axis of RF accelerating structures. The six different tuning concepts and that impacts on the longitudinal field distributions have been discussed in detail combining the RF tuning process of a 1:2 modeled 20.85 MV compact IH-DTL cavity, which was designed to accelerate proton, helium, oxygen or C{sup 4+} from 400 keV/u to 7 MeV/u and used as the linear injector of 430 MeV/u synchrotron [Y.R. Lu, S. Minaev, U. Ratzinger, B. Schlitt, R.Tiede, The Compact 20MV IH-DTL for the Heidelberg Therapy Facility, in: Proceedings of the LINAC Conference, Luebeck, Germany, 2004 ; Y.R. Lu, Frankfurt University Dissertation, 2005. ] in Heidelberg Heavy Ion Cancer Therapy (HICAT). Some of tuning concepts are also suitable and effective for the tuning of RFQ and/or other RF accelerating structures. Finally good field flatness in IH-DTL cavity has been realized successfully. The experience got from the model cavity tuning benefits real power cavity tuning, which is only needed to be tuned by the plungers. The cavity had a beam commissioning successfully for the initial beam acceleration at the end of 2006.

  8. The general RF tuning for IH-DTL linear accelerators

    Science.gov (United States)

    Lu, Y. R.; Ratzinger, U.; Schlitt, B.; Tiede, R.

    2007-11-01

    The RF tuning is the most important research for achieving the resonant frequency and the flatness of electric field distributions along the axis of RF accelerating structures. The six different tuning concepts and that impacts on the longitudinal field distributions have been discussed in detail combining the RF tuning process of a 1:2 modeled 20.85 MV compact IH-DTL cavity, which was designed to accelerate proton, helium, oxygen or C 4+ from 400 keV/ u to 7 MeV/u and used as the linear injector of 430 MeV/ u synchrotron [Y.R. Lu, S. Minaev, U. Ratzinger, B. Schlitt, R.Tiede, The Compact 20MV IH-DTL for the Heidelberg Therapy Facility, in: Proceedings of the LINAC Conference, Luebeck, Germany, 2004 [1]; Y.R. Lu, Frankfurt University Dissertation, 2005. [2

  9. Acceleration in the linear non-scaling fixed-field alternating-gradient accelerator EMMA

    Science.gov (United States)

    Machida, S.; Barlow, R.; Berg, J. S.; Bliss, N.; Buckley, R. K.; Clarke, J. A.; Craddock, M. K.; D'Arcy, R.; Edgecock, R.; Garland, J. M.; Giboudot, Y.; Goudket, P.; Griffiths, S.; Hill, C.; Hill, S. F.; Hock, K. M.; Holder, D. J.; Ibison, M. G.; Jackson, F.; Jamison, S. P.; Johnstone, C.; Jones, J. K.; Jones, L. B.; Kalinin, A.; Keil, E.; Kelliher, D. J.; Kirkman, I. W.; Koscielniak, S.; Marinov, K.; Marks, N.; Martlew, B.; McIntosh, P. A.; McKenzie, J. W.; Méot, F.; Middleman, K. J.; Moss, A.; Muratori, B. D.; Orrett, J.; Owen, H. L.; Pasternak, J.; Peach, K. J.; Poole, M. W.; Rao, Y.-N.; Saveliev, Y.; Scott, D. J.; Sheehy, S. L.; Shepherd, B. J. A.; Smith, R.; Smith, S. L.; Trbojevic, D.; Tzenov, S.; Weston, T.; Wheelhouse, A.; Williams, P. H.; Wolski, A.; Yokoi, T.

    2012-03-01

    In a fixed-field alternating-gradient (FFAG) accelerator, eliminating pulsed magnet operation permits rapid acceleration to synchrotron energies, but with a much higher beam-pulse repetition rate. Conceived in the 1950s, FFAGs are enjoying renewed interest, fuelled by the need to rapidly accelerate unstable muons for future high-energy physics colliders. Until now a `scaling' principle has been applied to avoid beam blow-up and loss. Removing this restriction produces a new breed of FFAG, a non-scaling variant, allowing powerful advances in machine characteristics. We report on the first non-scaling FFAG, in which orbits are compacted to within 10mm in radius over an electron momentum range of 12-18MeV/c. In this strictly linear-gradient FFAG, unstable beam regions are crossed, but acceleration via a novel serpentine channel is so rapid that no significant beam disruption is observed. This result has significant implications for future particle accelerators, particularly muon and high-intensity proton accelerators.

  10. Daily QA of linear accelerators using only EPID and OBI

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Baozhou, E-mail: bsun@radonc.wustl.edu; Goddu, S. Murty; Yaddanapudi, Sridhar; Noel, Camille; Li, Hua; Cai, Bin; Kavanaugh, James; Mutic, Sasa [Department of Radiation Oncology, Washington University School of Medicine, 4921 Parkview Place, Campus Box 8224, St. Louis, Missouri 63110 (United States)

    2015-10-15

    Purpose: As treatment delivery becomes more complex, there is a pressing need for robust quality assurance (QA) tools to improve efficiency and comprehensiveness while simultaneously maintaining high accuracy and sensitivity. This work aims to present the hardware and software tools developed for comprehensive QA of linear accelerator (LINAC) using only electronic portal imaging devices (EPIDs) and kV flat panel detectors. Methods: A daily QA phantom, which includes two orthogonally positioned phantoms for QA of MV-beams and kV onboard imaging (OBI) is suspended from the gantry accessory holder to test both geometric and dosimetric components of a LINAC and an OBI. The MV component consists of a 0.5 cm water-equivalent plastic sheet incorporating 11 circular steel plugs for transmission measurements through multiple thicknesses and one resolution plug for MV-image quality testing. The kV-phantom consists of a Leeds phantom (TOR-18 FG phantom supplied by Varian) for testing low and high contrast resolutions. In the developed process, the existing LINAC tools were used to automate daily acquisition of MV and kV images and software tools were developed for simultaneous analysis of these images. A method was developed to derive and evaluate traditional QA parameters from these images [output, flatness, symmetry, uniformity, TPR{sub 20/10}, and positional accuracy of the jaws and multileaf collimators (MLCs)]. The EPID-based daily QA tools were validated by performing measurements on a detuned 6 MV beam to test its effectiveness in detecting errors in output, symmetry, energy, and MLC positions. The developed QA process was clinically commissioned, implemented, and evaluated on a Varian TrueBeam LINAC (Varian Medical System, Palo Alto, CA) over a period of three months. Results: Machine output constancy measured with an EPID (as compared against a calibrated ion-chamber) is shown to be within ±0.5%. Beam symmetry and flatness deviations measured using an EPID and a 2D

  11. Accelerating sparse linear algebra using graphics processing units

    Science.gov (United States)

    Spagnoli, Kyle E.; Humphrey, John R.; Price, Daniel K.; Kelmelis, Eric J.

    2011-06-01

    The modern graphics processing unit (GPU) found in many standard personal computers is a highly parallel math processor capable of over 1 TFLOPS of peak computational throughput at a cost similar to a high-end CPU with excellent FLOPS-to-watt ratio. High-level sparse linear algebra operations are computationally intense, often requiring large amounts of parallel operations and would seem a natural fit for the processing power of the GPU. Our work is on a GPU accelerated implementation of sparse linear algebra routines. We present results from both direct and iterative sparse system solvers. The GPU execution model featured by NVIDIA GPUs based on CUDA demands very strong parallelism, requiring between hundreds and thousands of simultaneous operations to achieve high performance. Some constructs from linear algebra map extremely well to the GPU and others map poorly. CPUs, on the other hand, do well at smaller order parallelism and perform acceptably during low-parallelism code segments. Our work addresses this via hybrid a processing model, in which the CPU and GPU work simultaneously to produce results. In many cases, this is accomplished by allowing each platform to do the work it performs most naturally. For example, the CPU is responsible for graph theory portion of the direct solvers while the GPU simultaneously performs the low level linear algebra routines.

  12. RF properties of periodic accelerating structures for linear colliders

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J.W.

    1989-07-01

    With the advent of the SLAC electron-positron linear collider (SLC) in the 100 GeV center-of-mass energy range, research and development work on even higher energy machines of this type has started in several laboratories in the United States, Europe, the Soviet Union and Japan. These linear colliders appear to provide the only promising approach to studying e/sup /plus//e/sup /minus// physics at center-of-mass energies approaching 1 TeV. This thesis concerns itself with the study of radio frequency properties of periodic accelerating structures for linear colliders and their interaction with bunched beams. The topics that have been investigated are: experimental measurements of the energy loss of single bunches to longitudinal modes in two types of structures, using an equivalent signal on a coaxial wire to simulate the beam; a method of canceling the energy spread created within a single bunch by longitudinal wakefields, through appropriate shaping of the longitudinal charge distribution of the bunch; derivation of the complete transient beam-loading equation for a train of bunches passing through a constant-gradient accelerator section, with application to the calculation and minimization of multi-bunch energy spread; detailed study of field emission and radio frequency breakdown in disk-loaded structures at S-, C- and X-band frequencies under extremely high-gradient conditions, with special attention to thermal effects, radiation, sparking, emission of gases, surface damage through explosive emission and its possible control through RF-gas processing. 53 refs., 49 figs., 9 tabs.

  13. Improving linear accelerator service response with a real- time electronic event reporting system.

    Science.gov (United States)

    Hoisak, Jeremy D P; Pawlicki, Todd; Kim, Gwe-Ya; Fletcher, Richard; Moore, Kevin L

    2014-09-08

    To track linear accelerator performance issues, an online event recording system was developed in-house for use by therapists and physicists to log the details of technical problems arising on our institution's four linear accelerators. In use since October 2010, the system was designed so that all clinical physicists would receive email notification when an event was logged. Starting in October 2012, we initiated a pilot project in collaboration with our linear accelerator vendor to explore a new model of service and support, in which event notifications were also sent electronically directly to dedicated engineers at the vendor's technical help desk, who then initiated a response to technical issues. Previously, technical issues were reported by telephone to the vendor's call center, which then disseminated information and coordinated a response with the Technical Support help desk and local service engineers. The purpose of this work was to investigate the improvements to clinical operations resulting from this new service model. The new and old service models were quantitatively compared by reviewing event logs and the oncology information system database in the nine months prior to and after initiation of the project. Here, we focus on events that resulted in an inoperative linear accelerator ("down" machine). Machine downtime, vendor response time, treatment cancellations, and event resolution were evaluated and compared over two equivalent time periods. In 389 clinical days, there were 119 machine-down events: 59 events before and 60 after introduction of the new model. In the new model, median time to service response decreased from 45 to 8 min, service engineer dispatch time decreased 44%, downtime per event decreased from 45 to 20 min, and treatment cancellations decreased 68%. The decreased vendor response time and reduced number of on-site visits by a service engineer resulted in decreased downtime and decreased patient treatment cancellations.

  14. Longitudinal jitter analysis of linear accelerator electron gun

    CERN Document Server

    Mingshan, Liu; Iqbal, Munawar

    2015-01-01

    We present measurement and analyses of longitudinal timing jitter of Beijing Electron Positron Collider (BEPCII) linear accelerator electron gun. We simulated longitudinal jitter effect of the gun using PARMELA about beam performance including beam profile, average energy, energy spread, longitudinal phase of reference particle and XY emittance. The maximum percentage difference of the beam parameters are calculated to be; 100%, 13.27%, 42.24%, 7.79% and 65.01%, 86.81%, respectively due to which the bunching efficiency is reduced to 54%. The simulation results are in agreement with test and are helpful to optimize the beam parameters by tuning the trigger timing of the gun during the bunching process.

  15. Linear accelerator radiosurgery for arteriovenous malformations: Updated literature review.

    Science.gov (United States)

    Yahya, S; Heyes, G; Nightingale, P; Lamin, S; Chavda, S; Geh, I; Spooner, D; Cruickshank, G; Sanghera, P

    2017-04-01

    Arteriovenous malformations (AVMs) are the leading causing of intra-cerebral haemorrhage. Stereotactic radiosurgery (SRS) is an established treatment for arteriovenous malformations (AVM) and commonly delivered using Gamma Knife within dedicated radiosurgery units. Linear accelerator (LINAC) SRS is increasingly available however debate remains over whether it offers an equivalent outcome. The aim of this project is to evaluate the outcomes using LINAC SRS for AVMs used within a UK neurosciences unit and review the literature to aid decision making across various SRS platforms. Results have shown comparability across platforms and strongly supports that an adapted LINAC based SRS facility within a dynamic regional neuro-oncology department delivers similar outcomes (in terms of obliteration and toxicity) to any other dedicated radio-surgical platform. Locally available facilities can facilitate discussion between options however throughput will inevitably be lower than centrally based dedicated national radiosurgery units.

  16. Novel Approach to Linear Accelerator Superconducting Magnet System

    Energy Technology Data Exchange (ETDEWEB)

    Kashikhin, Vladimir; /Fermilab

    2011-11-28

    Superconducting Linear Accelerators include a superconducting magnet system for particle beam transportation that provides the beam focusing and steering. This system consists of a large number of quadrupole magnets and dipole correctors mounted inside or between cryomodules with SCRF cavities. Each magnet has current leads and powered from its own power supply. The paper proposes a novel approach to magnet powering based on using superconducting persistent current switches. A group of magnets is powered from the same power supply through the common, for the group of cryomodules, electrical bus and pair of current leads. Superconducting switches direct the current to the chosen magnet and close the circuit providing the magnet operation in a persistent current mode. Two persistent current switches were fabricated and tested. In the paper also presented the results of magnetic field simulations, decay time constants analysis, and a way of improving quadrupole magnetic center stability. Such approach substantially reduces the magnet system cost and increases the reliability.

  17. Cryogen free superconducting splittable quadrupole magnet for linear accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Kashikhin, V.S.; Andreev, N.; Kerby, J.; Orlov, Y.; Solyak, N.; Tartaglia, M.; Velev, G.; /Fermilab

    2011-09-01

    A new superconducting quadrupole magnet for linear accelerators was fabricated at Fermilab. The magnet is designed to work inside a cryomodule in the space between SCRF cavities. SCRF cavities must be installed inside a very clean room adding issues to the magnet design, and fabrication. The designed magnet has a splittable along the vertical plane configuration and could be installed outside of the clean room around the beam pipe previously connected to neighboring cavities. For more convenient assembly and replacement a 'superferric' magnet configuration with four racetrack type coils was chosen. The magnet does not have a helium vessel and is conductively cooled from the cryomodule LHe supply pipe and a helium gas return pipe. The quadrupole generates 36 T integrated magnetic field gradient, has 600 mm effective length, and the peak gradient is 54 T/m. In this paper the quadrupole magnetic, mechanical, and thermal designs are presented, along with the magnet fabrication overview and first test results.

  18. Terahertz radiation source using an industrial electron linear accelerator

    CERN Document Server

    Kalkal, Yashvir

    2015-01-01

    High power ($\\sim 100$ kW) industrial electron linear accelerators (linacs) are used for irradiation applications e.g., for pasteurization of food products, disinfection of medical waste, etc. We propose that high power electron beam from such an industrial linac can be first passed through an undulator to generate powerful terahertz (THz) radiation, and the spent electron beam coming out of the undulator can still be used for industrial applications. This will enhance the utilisation of a high power industrial linac. We have performed calculation of spontaneous emission in the undulator to show that for typical parameters, continuous terahertz radiation having power of the order of $\\mu$W can be produced, which may be useful for many scientific applications.

  19. Review of diagnostics for next generation linear accelerators

    CERN Document Server

    Ross, M

    2001-01-01

    New electron linac designs incorporate substantial advances in critical beam parameters such as beam loading and bunch length and will require new levels of performance in stability and phase space control. In the coming decade, e- (and e+) linacs will be built for a high power linear collider (TESLA, CLIC, JLC/NLC), for fourth generation X-ray sources (TESLA FEL, LCLS, Spring 8 FEL) and for basic accelerator research and development (Orion). Each project assumes significant instrumentation performance advances across a wide front. This review will focus on basic diagnostics for beam position and phase space monitoring. Research and development efforts aimed at high precision multi-bunch beam position monitors, transverse and longitudinal profile monitors and timing systems will be described.

  20. Laser-Induced Linear Electron Acceleration in Free Space

    CERN Document Server

    Wong, Liang Jie; Carbajo, Sergio; Fallahi, Arya; Soljačić, Marin; Joannopoulos, John D; Kärtner, Franz X; Kaminer, Ido

    2016-01-01

    Linear acceleration in free space is a topic that has been studied for over 20 years, and its ability to eventually produce high-quality, high energy multi-particle bunches has remained a subject of great interest. Arguments can certainly be made that such an ability is very doubtful. Nevertheless, we chose to develop an accurate and truly predictive theoretical formalism to explore this remote possibility in a computational experiment. The formalism includes exact treatment of Maxwell's equations, exact relativistic treatment of the interaction among the multiple individual particles, and exact treatment of the interaction at near and far field. Several surprising results emerged. For example, we find that 30 keV electrons (2.5% energy spread) can be accelerated to 7.7 MeV (2.5% spread) and to 205 MeV (0.25% spread) using 25 mJ and 2.5 J lasers respectively. These findings should hopefully guide and help develop compact, high-quality, ultra-relativistic electron sources, avoiding conventional limits imposed ...

  1. LIGA-fabricated compact mm-wave linear accelerator cavities.

    Energy Technology Data Exchange (ETDEWEB)

    Song, J.J.; Bajikar, S.S.; DeCarlo, F.; Kang, Y.W.; Kustom, R.L.; Mancini, D.C.; Nassiri, A.; Lai, B.; Feinerman, A.D.; White, V.

    1998-03-23

    Millimeter-wave rf cavities for use in linear accelerators, free-electron lasers, and mm-wave undulatory are under development at Argonne National Laboratory. Typical cavity dimensions are in the 1000 mm range, and the overall length of the accelerator structure, which consists of 30-100 cavities, is about 50-100 mm. An accuracy of 0.2% in the cavity dimensions is necessary in order to achieve a high Q-factor of the cavity. To achieve this these structures are being fabricated using deep X-ray lithography, electroforming, and assembly (LIGA). The first prototype cavity structures are designed for 108 GHz and 2p/3-mode operation. Input and output couplers are integrated with the cavity structures. The cavities are fabricated on copper substrates by electroforming copper into 1-mm-thick PMMA resists patterned by deep x-ray lithography and polishing the copper down to the desired thickness. These are fabricated separately and subsequently assembled with precision spacing and alignment using microspheres, optical fibers, or microfabricated spacers/alignment pieces. Details of the fabrication process, alignment, and assembly work are presented in here.

  2. Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head and neck treatments.

    Science.gov (United States)

    Paelinck, L; De Wagter, C; Van Esch, A; Duthoy, W; Depuydt, T; De Neve, W

    2005-02-07

    Skin toxicity has been reported for IMRT of head and neck cancer. The purpose of this study was to investigate the dose in the build-up region delivered by a 6 MV treatment plan for which important skin toxicity was observed. We also investigated if the different designs of the treatment head of an Elekta and a Varian linear accelerator, especially the lower position of the Varian multi-leaf collimator, give rise to different build-up doses. For regular square open beams, the build-up dose along the central beam axis is higher for the Varian machine than for the Elekta machine, both for 6 MV and 18 MV. At the Elekta machine at 18 MV, the superficial dose of a diamond shaped 10 x 10 cm2 field is 3.6% lower than the superficial dose of a regular 10 x 10 cm2 field. This effect is not seen at 6 MV. At the Varian machine, the superficial dose of the diamond shaped field is respectively 3.5 and 14.2% higher than the superficial dose of the regular 10 x 10 cm2 field for 6 MV and 18 MV. Despite the differences measured in build-up dose for single beams between the Elekta and the Varian linear accelerator, there were no measurable differences in superficial dose when a typical IMRT dose plan of 6 MV for a head and neck tumour is executed at the two machines.

  3. HOM-Free Linear Accelerating Structure for e+ e- Linear Collider at C-Band

    CERN Document Server

    Kubo, K

    2003-01-01

    HOM-free linear acceleration structure using the choke mode cavity (damped cavity) is now under design for e sup + e sup - linear collider project at C-band frequency (5712 MHz). Since this structure shows powerful damping effect on most of all HOMs, there is no multibunch problem due to long range wakefields. The structure will be equipped with the microwave absorbers in each cells and also the in-line dummy load in the last few cells. The straightness tolerance for 1.8 m long structure is closer than 30 (micro)m for 25% emittance dilution limit, which can be achieved by standard machining and braising techniques. Since it has good vacuum pumping conductance through annular gaps in each cell, instabilities due to the interaction of beam with the residual-gas and ions can be minimized.

  4. Shielding design of the linear accelerator at RAON: Accelerator tunnel and utility gallery

    Science.gov (United States)

    Kim, Suna; Kang, Bo Sun; Lee, Sangjin; Nam, Shinwoo; Chung, Yeonsei

    2015-10-01

    RAON is the first Korean heavy-ion accelerator for various rare-isotope experiments and will be constructed by the year of 2021. The building for the about 550-m-long superconducting linear accelerator at RAON has three divisions in the vertical layout: accelerator tunnel, intermediate tunnel, and utility gallery. One of the requirements for the building design is that the effective dose rate in the utility gallery should be well below the dose limit for workers. Other parts of the building underground are classified as high-radiation zones where access is strictly controlled. The radiation dose distribution in the building has been calculated by using the Monte Carlo transport code MCNPX including the radiation streaming effects through the intermediate tunnel and penetrating holes. We have applied a point beam loss model in which the continuous beam loss along the beam line is treated as an equivalent point loss with a simple target. We describe the details of the calculation and discuss the results.

  5. Additional dose assessment from the activation of high-energy linear accelerators used in radiation therapy

    Directory of Open Access Journals (Sweden)

    Ateia Embarka

    2008-01-01

    Full Text Available It is well known that medical linear accelerators generate activation products when operated above certain electron (photon energies. The aim of the present work is to assess the activation behavior of a medium-energy radiotherapy linear accelerator by applying in situ gamma-ray spectrometry and dose measurements, and to estimate the additional dose to radiotherapy staff on the basis of these results. Spectral analysis was performed parallel to dose rate measurements in the isocenter of the linear accelerator, immediately after the termination of irradiation. The following radioisotopes were detected by spectral analysis: 28Al, 62Cu, 56Mn, 64Cu, 187W, and 57Ni. The short-lived isotopes such as 28Al and 62Cu are the most important factors of the clinical routine, while the contribution to the radiation dose of medium-lived isotopes such as 56Mn, 57Ni, 64Cu, and 187W increases during the working day. Measured dose rates at the isocenter ranged from 2.2 µSv/h to 10 µSv/h in various measuring points of interest for the members of the radiotherapy staff. Within the period of 10 minutes, the dose rate decreased to values of 0.8 µSv/h. According to actual workloads in radiotherapy departments, a realistic exposure scenario was set, resulting in a maximal additional annual whole body dose to the radiotherapy staff of about 3.5 mSv.

  6. Hamiltonian analysis for linearly acceleration-dependent Lagrangians

    Science.gov (United States)

    Cruz, Miguel; Gómez-Cortés, Rosario; Molgado, Alberto; Rojas, Efraín

    2016-06-01

    We study the constrained Ostrogradski-Hamilton framework for the equations of motion provided by mechanical systems described by second-order derivative actions with a linear dependence in the accelerations. We stress out the peculiar features provided by the surface terms arising for this type of theories and we discuss some important properties for this kind of actions in order to pave the way for the construction of a well defined quantum counterpart by means of canonical methods. In particular, we analyse in detail the constraint structure for these theories and its relation to the inherent conserved quantities where the associated energies together with a Noether charge may be identified. The constraint structure is fully analyzed without the introduction of auxiliary variables, as proposed in recent works involving higher order Lagrangians. Finally, we also provide some examples where our approach is explicitly applied and emphasize the way in which our original arrangement results in propitious for the Hamiltonian formulation of covariant field theories.

  7. Environmental Survey preliminary report, Stanford Linear Accelerator Center, Stanford, California

    Energy Technology Data Exchange (ETDEWEB)

    1988-07-01

    This report presents the preliminary findings from the first phase of the Survey of the US Department of Energy (DOE) Stanford Linear Accelerator Center (SLAC) at Stanford, California, conducted February 29 through March 4, 1988. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual team components are being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the SLAC. The Survey covers all environmental media and all areas of environmental regulation and is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations at the SLAC, and interviews with site personnel. The Survey team is developing a Sampling and Analysis Plan to assist in further assessing certain of the environmental problems identified during its on-site activities. The Sampling and Analysis Plan will be executed by a DOE National Laboratory or a support contractor. When completed, the results will be incorporated into the Environmental Survey Interim Report for the SLAC facility. The Interim Report will reflect the final determinations of the SLAC Survey. 95 refs., 25 figs., 25 tabs.

  8. Portable X-Band Linear Electron Accelerators for Radiographic Applications

    CERN Document Server

    Saverskiy, Aleksandr J; Hernandez, Michael; Mishin, Andrey V; Skowbo, Dave

    2005-01-01

    The MINAC series portable linear electron accelerator systems designed and manufactured at American Science and Engineering, Inc. High Energy Systems Division (AS&E HESD) are discussed in this paper. Each system can be configured as either an X-ray or electron beam source. The powerful 4 MeV and 6 MeV linacs powered by a 1,5 MW magnetron permit operation in a dose rate range from 100 R/min at 80 cm to 600 R/min at 80 cm. Each MINAC is a self-contained source with radiation leakage outside of the X-ray head less than 0,1% of the maximum dose. Along with these systems a 1 MeV ultra compact MINAC has been successfully tested. The unit is available with radiation leakage less then 0.01% and permits producing X-ray beam in an energy range (1…2) MeV at a high output dose rate. Design and experimental parameters are presented. The common and system specific features are also discussed.

  9. Multipurpose 5-MeV linear induction accelerator

    Science.gov (United States)

    Birx, D. L.; Hawkins, S. A.; Poor, S. E.; Reginato, L. L.; Smith, M. W.

    1984-06-01

    Although linear induction accelerators (LIAs) are quite reliable by most standards, they are limited in repeating rate, average power, and reliability because the final stage of energy delivery is based on spark gap performance. In addition, they have a low duty factor of operation. To provide a higher burst rate and greater reliability, new technology was used to develop a magnetic pulse compression scheme that eliminates all spark gaps and exceeds requirements. The magnetic drive system are tailored to drive induction cells from a few kA to over 10 kA at 500 kV, with average beam power levels in the megawatts. This new 5-MeV, 2.5-kA LIA under construction at the Lawrence Livermore National Laboratory (LLNL) will be used for the development of high brightness sources and will provide a test bed for the new technology, which should lead to LIAs that surpass the radio frequency linacs for efficiency and reliability, as well as fit other industrial applications, such as sewage sterilization.

  10. Multipurpose 5-MeV linear induction accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Birx, D.L.; Hawkins, S.A.; Poor, S.E.; Reginato, L.L. Smith, M.W.

    1984-06-11

    Although linear induction accelerators (LIAs) are quite reliable by most standards, they are limited in repeating rate, average power, and reliability because the final stage of energy delivery is based on spark gap performance. In addition, they have a low duty factor of operation. To provide a higher burst rate and greater reliability, the researchers used new technology to develop a magnetic pulse compression scheme that eliminates all spark gaps and exceeds requirements. The paper describes the scheme. The magnetic drive system can be tailored to drive induction cells from a few kA to over 10 kA at 500 kV, with average beam power levels in the megawatts. This new 5-MeV, 2.5-kA LIA under construction at the Lawrence Livermore National Laboratory (LLNL) will be used for the development of high brightness sources and will provide a test bed for the new technology, which should lead to LIAs that surpass the radio frequency linacs for efficiency and reliability, as well as fit other industrial applications, such as sewage sterilization.

  11. Radiation doses inside industrial irradiation installation with linear electron accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Alexandre R., E-mail: alexandre.lima@cnen.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Pelegrineli, Samuel Q.; Alo, Gabriel F., E-mail: samuelfisica@yahoo.com.br, E-mail: gabriel.alo@aceletron.com.br [Aceletron Irradiacao Industrial, Aceletrica Comercio e Representacoes Ltda, Rio de Janeiro, RJ (Brazil); Silva, Francisco C.A. Da, E-mail: dasilva@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Aceletron Industrial Irradiation Company is the unique installation in South America to provide industrial irradiation service using two linear electron accelerators of 18 kW and 10 MeV energy. The electron beam technology allows using electrons to irradiate many goods and materials, such as hospital and medical equipment, cosmetics, herbal products, polymers, peat, gemstones and food. Aceletron Company uses a concrete bunker with 3.66 m of thickness to provide the necessary occupational and environmental radiation protection of X-rays produced. The bunker is divided in main four areas: irradiation room, maze, tower and pit. Inside the irradiation room the x-rays radiation rates are measured in two ways: direct beam and 90 deg C. The rates produced in the conveyor system using 10 MeV energy are 500 Gy/min/mA and 15 Gy/min/mA, respectively. For a 1.8 mA current, the rates produced are 900 Gy/min and 27 Gy/min, respectively. Outside the bunker the radiation rate is at background level, but in the tower door and modulation room the radiation rate is 10 μSv/h. In 2014, during a routine operation, an effective dose of 30.90 mSv was recorded in a monthly individual dosimeter. After the investigation, it was concluded that the dose was only in the dosimeter because it felt inside the irradiation room. As Aceletron Company follows the principles of safety culture, it was decided to perform the radiation isodose curves, inside the four areas of the installation, to know exactly the hotspots positions, exposure times and radiation doses. Five hotspots were chosen taking into account worker's routes and possible operational places. The first experiment was done using a package with three TLD and OSLD dosimeters to obtain better statistical results. The first results for the five hotspots near the accelerator machine showed that the radiation dose rates were between 26 Gy/h and 31 Gy/h. The final measurements were performed using a package with one TLD and one OSLD

  12. Tuning the DARHT Axis-II linear induction accelerator focusing

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Carl A. [Los Alamos National Laboratory

    2012-04-24

    Flash radiography of large hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories, and the Dual-Axis Radiography for Hydrodynamic Testing (DARHT) facility at Los Alamos produces flash radiographs of large hydrodynamic experiments. Two linear induction accelerators (LIAs) make the bremsstrahlung radiographic source spots for orthogonal views of each test. The 2-kA, 20-MeV Axis-I LIA creates a single 60-ns radiography pulse. The 1.7-kA, 16.5-MeV Axis-II LIA creates up to four radiography pulses by kicking them out of a longer pulse that has a 1.6-{mu}s flattop. The Axis-II injector, LIA, kicker, and downstream transport (DST) to the bremsstrahlung converter are described. Adjusting the magnetic focusing and steering elements to optimize the electron-beam transport through an LIA is often called 'tuning.' As in all high-current LIAs, the focusing field is designed to be as close to that of the ideal continuous solenoid as physically possible. In ideal continuous solenoidal transport a smoothly varying beam size can easily be found for which radial forces balance, and the beam is said to be 'matched' to the focusing field. A 'mismatched' beam exhibits unwanted oscillations in size, which are a source of free energy that contributes to emittance growth. This is undesirable, because in the absence of beam-target effects, the radiographic spot size is proportional to the emittance. Tuning the Axis-II LIA is done in two steps. First, the solenoidal focusing elements are set to values designed to provide a matched beam with little or no envelope oscillations, and little or no beam-breakup (BBU) instability growth. Then, steering elements are adjusted to minimize the motion of the centroid of a well-centered beam at the LIA exit. This article only describes the design of the tune for the focusing solenoids. The DARHT Axis-II LIA was required to be re-tuned after installing an

  13. Method for validating radiobiological samples using a linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Brengues, Muriel [The University of Arizona College of Medicine, Center for Applied NanoBioscience and Medicine, Phoenix, AZ (United States); Liu, David; Korn, Ronald [Scottsdale Clinical Research Institute, Scottsdale Healthcare, Scottsdale, AZ (United States); Zenhausern, Frederic [The University of Arizona College of Medicine, Center for Applied NanoBioscience and Medicine, Phoenix, AZ (United States); Scottsdale Clinical Research Institute, Scottsdale Healthcare, Scottsdale, AZ (United States)

    2014-12-15

    There is an immediate need for rapid triage of the population in case of a large scale exposure to ionizing radiation. Knowing the dose absorbed by the body will allow clinicians to administer medical treatment for the best chance of recovery for the victim. In addition, today's radiotherapy treatment could benefit from additional information regarding the patient's sensitivity to radiation before starting the treatment. As of today, there is no system in place to respond to this demand. This paper will describe specific procedures to mimic the effects of human exposure to ionizing radiation creating the tools for optimization of administered radiation dosimetry for radiotherapy and/or to estimate the doses of radiation received accidentally during a radiation event that could pose a danger to the public. In order to obtain irradiated biological samples to study ionizing radiation absorbed by the body, we performed ex-vivo irradiation of human blood samples using the linear accelerator (LINAC). The LINAC was implemented and calibrated for irradiating human whole blood samples. To test the calibration, a 2 Gy test run was successfully performed on a tube filled with water with an accuracy of 3% in dose distribution. To validate our technique the blood samples were ex-vivo irradiated and the results were analyzed using a gene expression assay to follow the effect of the ionizing irradiation by characterizing dose responsive biomarkers from radiobiological assays. The response of 5 genes was monitored resulting in expression increase with the dose of radiation received. The blood samples treated with the LINAC can provide effective irradiated blood samples suitable for molecular profiling to validate radiobiological measurements via the gene-expression based biodosimetry tools. (orig.)

  14. RF linear accelerators for medical and industrial applications

    CERN Document Server

    Hanna, Samy

    2012-01-01

    This unique resource offers you a clear overview of medical and industrial accelerators. Using minimal mathematics, this book focuses on offering thorough explanations of basic concepts surrounding the operation of accelerators. you find well illustrated discussions designed to help you use accelerator-based systems in a safer, more productive, and more reliable manner.This practical book details the manufacturing process for producing accelerators for medical and industrial applications. You become knowledgeable about the commonly encountered real-world manufacturing issues and potential sources of defects which help you avoid costly production problems. From principles of operation and the role of accelerators in cancer radiation therapy, to manufacturing techniques and future trends in accelerator design and applications, this easy-to-comprehend volume quickly brings you up-to-speed with the critical concepts you need to understand for your work in the field.

  15. BBU design of linear induction accelerator cells for radiography application

    Energy Technology Data Exchange (ETDEWEB)

    Shang, C.C.; Chen, Y.J.; Gaporaso, G.J.; Houck, T.L.; Molau, N.E.; Focklen, J.; Gregory, S.

    1997-05-06

    There is an ongoing effort to develop accelerating modules for high-current electron accelerators for advanced radiography application. Accelerating modules with low beam-cavity coupling impedances along with gap designs with acceptable field stresses comprise a set of fundamental design criteria. We examine improved cell designs which have been developed for accelerator application in several radiographic operating regimes. We evaluate interaction impedances, analyze the effects of beam structure coupling on beam dynamics (beam break-up instability and corkscrew motion). We also provide estimates of coupling through interesting new high-gradient insulators and evaluate their potential future application in induction cells.

  16. Acceleration of the direct reconstruction of linear parametric images using nested algorithms.

    Science.gov (United States)

    Wang, Guobao; Qi, Jinyi

    2010-03-01

    Parametric imaging using dynamic positron emission tomography (PET) provides important information for biological research and clinical diagnosis. Indirect and direct methods have been developed for reconstructing linear parametric images from dynamic PET data. Indirect methods are relatively simple and easy to implement because the image reconstruction and kinetic modeling are performed in two separate steps. Direct methods estimate parametric images directly from raw PET data and are statistically more efficient. However, the convergence rate of direct algorithms can be slow due to the coupling between the reconstruction and kinetic modeling. Here we present two fast gradient-type algorithms for direct reconstruction of linear parametric images. The new algorithms decouple the reconstruction and linear parametric modeling at each iteration by employing the principle of optimization transfer. Convergence speed is accelerated by running more sub-iterations of linear parametric estimation because the computation cost of the linear parametric modeling is much less than that of the image reconstruction. Computer simulation studies demonstrated that the new algorithms converge much faster than the traditional expectation maximization (EM) and the preconditioned conjugate gradient algorithms for dynamic PET.

  17. [From clinical judgment to linear regression model.

    Science.gov (United States)

    Palacios-Cruz, Lino; Pérez, Marcela; Rivas-Ruiz, Rodolfo; Talavera, Juan O

    2013-01-01

    When we think about mathematical models, such as linear regression model, we think that these terms are only used by those engaged in research, a notion that is far from the truth. Legendre described the first mathematical model in 1805, and Galton introduced the formal term in 1886. Linear regression is one of the most commonly used regression models in clinical practice. It is useful to predict or show the relationship between two or more variables as long as the dependent variable is quantitative and has normal distribution. Stated in another way, the regression is used to predict a measure based on the knowledge of at least one other variable. Linear regression has as it's first objective to determine the slope or inclination of the regression line: Y = a + bx, where "a" is the intercept or regression constant and it is equivalent to "Y" value when "X" equals 0 and "b" (also called slope) indicates the increase or decrease that occurs when the variable "x" increases or decreases in one unit. In the regression line, "b" is called regression coefficient. The coefficient of determination (R(2)) indicates the importance of independent variables in the outcome.

  18. A dosimetric characterization of a novel linear accelerator collimator

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, C. M.; Weston, S. J., E-mail: steve.weston@leedsth.nhs.uk; Cosgrove, V. C. [Leeds Cancer Centre, Bexley Wing, St. James’ University Hospital, Leeds LS9 7TF (United Kingdom); Thwaites, D. I. [Institute of Medical Physics, School of Physics, University of Sydney, Sydney NSW 2006, Australia and Division of Medical Physics, Leeds Institute of Genetics, Health and Therapeutics, University of Leeds, Leeds LS2 9JT (United Kingdom)

    2014-03-15

    Purpose: The aim of this work is to characterize a new linear accelerator collimator which contains a single pair of sculpted diaphragms mounted orthogonally to a 160 leaf multileaf collimator (MLC). The diaphragms have “thick” regions providing full attenuation and “thin” regions where attenuation is provided by both the leaves and the diaphragm. The leaves are mounted on a dynamic leaf guide allowing rapid leaf motion and leaf travel over 350 mm. Methods: Dosimetric characterization, including assessment of leaf transmission, leaf tip transmission, penumbral width, was performed in a plotting tank. Head scatter factor was measured using a mini-phantom and the effect of leaf guide position on output was assessed using a water phantom. The tongue and groove effect was assessed using multiple exposures on radiochromic film. Leaf reproducibility was assessed from portal images of multiple abutting fields. Results: The maximum transmission through the multileaf collimator is 0.44% at 6 MV and 0.52% at 10 MV. This reduced to 0.22% and 0.27%, respectively, when the beam passes through the dynamic leaf guide in addition to the MLC. The maximum transmission through the thick part of the diaphragm is 0.32% and 0.36% at 6 and 10 MV. The combination of leaf and diaphragm transmission ranges from 0.08% to 0.010% at 6 MV and 0.10% to 0.14% depending on whether the shielding is through the thick or thin part of the diaphragm. The off-axis intertip transmission for a zero leaf gap is 2.2% at 6 and 10 MV. The leaf tip penumbra for a 100 × 100 mm field ranges from 5.4 to 4.3 mm at 6 and 10 MV across the full range of leaf motion when measured in the AB direction, which reduces to 4.0–3.4 mm at 6 MV and 4.5–3.8 mm at 10 MV when measured in the GT direction. For a 50 × 50 mm field, the diaphragm penumbra ranges from 4.3 to 3.7 mm at 6 MV and 4.5 to 4.1 mm at 10 MV in the AB direction and 3.7 to 3.2 mm at 6 MV and 4.2 to 3.7 mm when measured in the GT direction. The

  19. Proceedings of the Oak Ridge Electron Linear Accelerator (ORELA) Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, M.E.

    2006-02-27

    The Oak Ridge National Laboratory (ORNL) organized a workshop at ORNL July 14-15, 2005, to highlight the unique measurement capabilities of the Oak Ridge Electron Linear Accelerator (ORELA) facility and to emphasize the important role of ORELA for performing differential cross-section measurements in the low-energy resonance region that is important for nuclear applications such as nuclear criticality safety, nuclear reactor and fuel cycle analysis, stockpile stewardship, weapons research, medical diagnosis, and nuclear astrophysics. The ORELA workshop (hereafter referred to as the Workshop) provided the opportunity to exchange ideas and information pertaining to nuclear cross-section measurements and their importance for nuclear applications from a variety of perspectives throughout the U.S. Department of Energy (DOE). Approximately 50 people, representing DOE, universities, and seven U.S. national laboratories, attended the Workshop. The objective of the Workshop was to emphasize the technical community endorsement for ORELA in meeting nuclear data challenges in the years to come. The Workshop further emphasized the need for a better understanding of the gaps in basic differential nuclear measurements and identified the efforts needed to return ORELA to a reliable functional measurement facility. To accomplish the Workshop objective, nuclear data experts from national laboratories and universities were invited to provide talks emphasizing the unique and vital role of the ORELA facility for addressing nuclear data needs. ORELA is operated on a full cost-recovery basis with no single sponsor providing complete base funding for the facility. Consequently, different programmatic sponsors benefit by receiving accurate cross-section data measurements at a reduced cost to their respective programs; however, leveraging support for a complex facility such as ORELA has a distinct disadvantage in that the programmatic funds are only used to support program

  20. Proceedings of the Oak Ridge Electron Linear Accelerator (ORELA) Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, M.E.

    2006-02-27

    The Oak Ridge National Laboratory (ORNL) organized a workshop at ORNL July 14-15, 2005, to highlight the unique measurement capabilities of the Oak Ridge Electron Linear Accelerator (ORELA) facility and to emphasize the important role of ORELA for performing differential cross-section measurements in the low-energy resonance region that is important for nuclear applications such as nuclear criticality safety, nuclear reactor and fuel cycle analysis, stockpile stewardship, weapons research, medical diagnosis, and nuclear astrophysics. The ORELA workshop (hereafter referred to as the Workshop) provided the opportunity to exchange ideas and information pertaining to nuclear cross-section measurements and their importance for nuclear applications from a variety of perspectives throughout the U.S. Department of Energy (DOE). Approximately 50 people, representing DOE, universities, and seven U.S. national laboratories, attended the Workshop. The objective of the Workshop was to emphasize the technical community endorsement for ORELA in meeting nuclear data challenges in the years to come. The Workshop further emphasized the need for a better understanding of the gaps in basic differential nuclear measurements and identified the efforts needed to return ORELA to a reliable functional measurement facility. To accomplish the Workshop objective, nuclear data experts from national laboratories and universities were invited to provide talks emphasizing the unique and vital role of the ORELA facility for addressing nuclear data needs. ORELA is operated on a full cost-recovery basis with no single sponsor providing complete base funding for the facility. Consequently, different programmatic sponsors benefit by receiving accurate cross-section data measurements at a reduced cost to their respective programs; however, leveraging support for a complex facility such as ORELA has a distinct disadvantage in that the programmatic funds are only used to support program

  1. Computation of Normal Conducting and Superconducting Linear Accelerator (LINAC) Availabilities

    Energy Technology Data Exchange (ETDEWEB)

    Haire, M.J.

    2000-07-11

    A brief study was conducted to roughly estimate the availability of a superconducting (SC) linear accelerator (LINAC) as compared to a normal conducting (NC) one. Potentially, SC radio frequency cavities have substantial reserve capability, which allows them to compensate for failed cavities, thus increasing the availability of the overall LINAC. In the initial SC design, there is a klystron and associated equipment (e.g., power supply) for every cavity of an SC LINAC. On the other hand, a single klystron may service eight cavities in the NC LINAC. This study modeled that portion of the Spallation Neutron Source LINAC (between 200 and 1,000 MeV) that is initially proposed for conversion from NC to SC technology. Equipment common to both designs was not evaluated. Tabular fault-tree calculations and computer-event-driven simulation (EDS) computer computations were performed. The estimated gain in availability when using the SC option ranges from 3 to 13% under certain equipment and conditions and spatial separation requirements. The availability of an NC LINAC is estimated to be 83%. Tabular fault-tree calculations and computer EDS modeling gave the same 83% answer to within one-tenth of a percent for the NC case. Tabular fault-tree calculations of the availability of the SC LINAC (where a klystron and associated equipment drive a single cavity) give 97%, whereas EDS computer calculations give 96%, a disagreement of only 1%. This result may be somewhat fortuitous because of limitations of tabular fault-tree calculations. For example, tabular fault-tree calculations can not handle spatial effects (separation distance between failures), equipment network configurations, and some failure combinations. EDS computer modeling of various equipment configurations were examined. When there is a klystron and associated equipment for every cavity and adjacent cavity, failure can be tolerated and the SC availability was estimated to be 96%. SC availability decreased as

  2. Characterizing THz Coherent Synchrotron Radiation at Femtosecond Linear Accelerator

    Institute of Scientific and Technical Information of China (English)

    LIN Xu-Ling; ZHANG Jian-Bing; LU YU; LUO Feng; LU Shan-Liang; YU Tie-Min; DAI Zhi-Min

    2009-01-01

    The generation and observation of coherent THz synchrotron radiation from femtosecond electron bunches in the Shanghai Institute of Applied Physics femtosecond accelerator device is reported.We describe the experiment setup and present the first result of THz radiation properties such as power and spectrum.

  3. Accelerating R with high performance linear algebra libraries

    Directory of Open Access Journals (Sweden)

    Bogdan Oancea

    2015-09-01

    Full Text Available Linear algebra routines are basic building blocks for the statistical software. In this paper we analyzed how can we improve R performance for matrix computations. We benchmarked few matrix operations using the standard linear algebra libraries included in the R distribution and high performance libraries like OpenBLAS, GotoBLAS and MKL. Our tests showed the best results are obtained with the MKL library, the other two libraries having similar performances, but lower than MKL.

  4. Beam dynamics design for uranium drift tube linear accelerator

    Science.gov (United States)

    Dou, Wei-Ping; He, Yuan; Lu, Yuan-Rong

    2014-07-01

    KONUS beam dynamics design of uranium DTL with LORASR code is presented. The 238U34+ beam, whose current is 5.0 emA, is accelerated from injection energy of 0.35 MeV/u to output energy of 1.30 MeV/u by IH-DTL operated at 81.25 MHz in HIAF project at IMP of CAS. It achieves a transmission efficiency of 94.95% with a cavity length of 267.8 cm. The optimization aims are the reduction of emittance growth, beam loss and project costs. Because of the requirements of CW mode operation, the designed average acceleration gradient is about 2.48 MV/m. The maximum axial field is 10.2 MV/m, meanwhile the Kilpatrick breakdown field is 10.56 MV/m at 81.25 MHz.

  5. An organizational survey of the Stanford Linear Accelerator Center

    Energy Technology Data Exchange (ETDEWEB)

    Shurberg, D.A.; Haber, S.B.

    1991-11-01

    At the request of the Department of Energy, an Organizational Survey (OS) was administered at the Stanford Accelerator Center (SLAC). The OS measured employees' opinions on subjects such as organizational culture, communication, commitment, group cohesion, coordination, safety, environmental issues, and job satisfaction. The result of this work was a quantitative measure of the notion of culture at the SLAC site. This report presents these results and discusses their interpretation.

  6. An organizational survey of the Stanford Linear Accelerator Center

    Energy Technology Data Exchange (ETDEWEB)

    Shurberg, D.A.; Haber, S.B.

    1991-11-01

    At the request of the Department of Energy, an Organizational Survey (OS) was administered at the Stanford Accelerator Center (SLAC). The OS measured employees` opinions on subjects such as organizational culture, communication, commitment, group cohesion, coordination, safety, environmental issues, and job satisfaction. The result of this work was a quantitative measure of the notion of culture at the SLAC site. This report presents these results and discusses their interpretation.

  7. Cryogenic system for the MYRRHA superconducting linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Chevalier, Nicolas R.; Junquera, Tomas [Accelerators and Cryogenic Systems, 86, rue de Paris, 91400 Orsay (France); Thermeau, Jean-Pierre [Institut de Physique Nucléaire, Université Paris Sud, 91400 Orsay (France); Romão, Luis Medeiros; Vandeplassche, Dirk [SCK-CEN, Boeretang 200, 2400 Mol (Belgium)

    2014-01-29

    SCK⋅CEN, the Belgian Nuclear Research Centre, is designing MYRRHA, a flexible fast spectrum research reactor (80 MW{sub th}), conceived as an accelerator driven system (ADS), able to operate in sub-critical and critical modes. It contains a continuous-wave (CW) superconducting (SC) proton accelerator of 600 MeV, a spallation target and a multiplying core with MOX fuel, cooled by liquid lead-bismuth (Pb-Bi). From 17 MeV onward, the SC accelerator will consist of 48 β=0.36 spoke-loaded cavities (352 MHz), 34 β=0.47 elliptical cavities (704 MHz) and 60 β=0.65 elliptical cavities (704 MHz). We present an analysis of the thermal loads and of the optimal operating temperature of the cryogenic system. In particular, the low operating frequency of spoke cavities makes their operation in CW mode possible both at 4.2 K or at 2 K. Our analysis outlines the main factors that determine at what temperature the spoke cavities should be operated. We then present different cryogenic fluid distribution schemes, important characteristics (storage, transfer line, etc.) and the main challenges offered by MYRRHA in terms of cryogenics.

  8. Jacobs Engineering Group Inc. receives architectural and engineering design contract from Stanford Linear Accelerator Centre

    CERN Multimedia

    2004-01-01

    "Jacobs Engineering Group Inc. announced that a subsidiary company won a contract from Stanford Linear Accelerator Center (SLAC), to provide architectural and engineering design services for the Linac Coherent Light Source (LCLS) conventional facilities" (1/2 page)

  9. SU-E-T-124: Anthropomorphic Phantoms for Confirmation of Linear Accelerator Based Small Animal Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Perks, J; Benedict, S [UC Davis Cancer Center, Sacramento, CA (United States); Lucero, S [UC Davis, Davis, CA (United States)

    2015-06-15

    Purpose: To document the support of radiobiological small animal research by a modern radiation oncology facility. This study confirms that a standard, human use linear accelerator can cover the range of experiments called for by researchers performing animal irradiation. A number of representative, anthropomorphic murine phantoms were made. The phantoms confirmed the small field photon and electron beams dosimetry validated the use of the linear accelerator for rodents. Methods: Laser scanning a model, CAD design and 3D printing produced the phantoms. The phantoms were weighed and CT scanned to judge their compatibility to real animals. Phantoms were produced to specifically mimic lung, gut, brain, and othotopic lesion irradiations. Each phantom was irradiated with the same protocol as prescribed to the live animals. Delivered dose was measured with small field ion chambers, MOS/FETs or TLDs. Results: The density of the phantom material compared to density range across the real mice showed that the printed material would yield sufficiently accurate measurements when irradiated. The whole body, lung and gut irradiations were measured within 2% of prescribed doses with A1SL ion chamber. MOSFET measurements of electron irradiations for the orthotopic lesions allowed refinement of the measured small field output factor to better than 2% and validated the immunology experiment of irradiating one lesion and sparing another. Conclusion: Linacs are still useful tools in small animal bio-radiation research. This work demonstrated a strong role for the clinical accelerator in small animal research, facilitating standard whole body dosing as well as conformal treatments down to 1cm field. The accuracy of measured dose, was always within 5%. The electron irradiations of the phantom brain and flank tumors needed adjustment; the anthropomorphic phantoms allowed refinement of the initial output factor measurements for these fields which were made in a large block of solid water.

  10. Traveling wave linear accelerator with RF power flow outside of accelerating cavities

    Science.gov (United States)

    Dolgashev, Valery A.

    2016-06-28

    A high power RF traveling wave accelerator structure includes a symmetric RF feed, an input matching cell coupled to the symmetric RF feed, a sequence of regular accelerating cavities coupled to the input matching cell at an input beam pipe end of the sequence, one or more waveguides parallel to and coupled to the sequence of regular accelerating cavities, an output matching cell coupled to the sequence of regular accelerating cavities at an output beam pipe end of the sequence, and output waveguide circuit or RF loads coupled to the output matching cell. Each of the regular accelerating cavities has a nose cone that cuts off field propagating into the beam pipe and therefore all power flows in a traveling wave along the structure in the waveguide.

  11. Fast online Monte Carlo-based IMRT planning for the MRI linear accelerator

    NARCIS (Netherlands)

    Bol, G.H.; Hissoiny, S.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2012-01-01

    The MRI accelerator, a combination of a 6 MV linear accelerator with a 1.5 T MRI, facilitates continuous patient anatomy updates regarding translations, rotations and deformations of targets and organs at risk. Accounting for these demands high speed, online intensity-modulated radiotherapy (IMRT) r

  12. Linear accelerators for high energies. A report on the 1962 conference at Brookhaven

    Energy Technology Data Exchange (ETDEWEB)

    Blewett, John P.

    1963-01-01

    The linear accelerator was invented very early in the history of particle accelerators, but it has been one of the latest accelerators to be exploited. This is principally because of the very large quantities of radio-frequency power required to attain respectable energies in a reasonable distance. Radar developments during World War II resulted in production of the necessary megawatt oscillators or amplifiers, and linear accelerators, both for electrons and positive ions, are now operating in several centers. The electron linear accelerator has been extended to billion-volt energies, and in the Stanford two-mile version it will soon set new energy records between 20 and 40 BeV. The proton linear accelerator has had a less spectacular history. The highest energy yet achieved in a proton linac is about 70 MeV (at the University of Minnesota). Smaller proton linacs are in use as injectors for proton-synchrotrons, but no machine has been built or is under construction for the range above 100 MeV. This is because synchro-cyclotrons for this energy range are much cheaper and have been preferred for this reason, in spite of the fact that the beam from a synchro-cyclotron cannot be nearly as intense or as well collimated as the beam from a linear accelerator.

  13. Characteristic parameters of 6--21 MeV electron beams from a 21 MeV linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Al-Ghazi, M.S.A.L. (Department of Medical Physics, Thunder Bay Regional Cancer Centre, Ontario Cancer Treatment and Research Foundation, Thunder Bay, Ontario P7A 7T1, (Canada) Department of Physics, Lakehead University, Thunder Bay, Ontario P7B 5E1, (Canada) Lingman, D. Department of Medical Physics, Thunder Bay Regional Cancer Centre, Ontario Cancer Treatment and Research Foundation, Thunder Bay, Ontario P7A 7T1, (Canada) Department of Computer Science, Lakehead University, Thunder Bay, Ontario P7B 5E1, (Canada)); Gilbert, L.D. (Thekkumthala, J. Department of Medical Physics, Thunder Bay Regional Cancer Centre, Ontario Cancer Treatment and Research Foundation, Thunder Bay, Ontario P7A 7T1, (Canada))

    1991-07-01

    Dosimetry measurements have been carried out for the electron beams produced by a linear accelerator at energies 6, 8, 10, 14, 18, and 21 MeV. Characteristic parameters of the central axis dose distributions were derived and compared to corresponding values of electron beams from other accelerators in clinical use where such a comparison is appropriate. A comprehensive set of dosimetric parameters is provided for electron beam treatment planning. The data include central axis depth dose, range--energy parameters, beam penumbra and uniformity.

  14. Radiosurgery with photon beams; Physical aspects and adequacy of linear accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Podgorsak, E.B.; Pla, M.; Souhami, L. (McGill University, Montreal (Canada). Department of Radiation Oncology); Pike, G.B.; Olivier, A. (McGill University, Montreal (Canada). Department of Neurosurgery)

    1990-03-01

    The question of the adequacy of isocentric linear accelerators (linacs) for use in radiosurgery is addressed. The general physical requirements for radiosurgery, mainly a high spatial and numerical accuracy of dose delivery, reasonable treatment time, and low skin and leakage dose as well as cost considerations are examined. Various linac-based procedures are analyzed in view of their ability to meet these requirements and are contrasted with the clinically proven system of the Gamma unit. It is shown that the linac-based multiple converging arcs techniques and the dynamic rotation meet the stringent physical requirements on dose delivery and are thus viable alternatives to radiosurgery with the commercially available and dedicated Gamma unit. (author). 15 refs.; 2 figs.; 1 tab.

  15. Beam dynamics simulation of the Spallation Neutron Source linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, H.; Billen, J.H.; Bhatia, T.S.

    1998-12-31

    The accelerating structure for Spallation Neutron Source (SNS) consists of a radio-frequency-quadrupole-linac (RFQ), a drift-tube-linac (DTL), a coupled-cavity-drift-tube-linac (CCDTL), and a coupled-cavity-linac (CCL). The linac is operated at room temperature. The authors discuss the detailed design of linac which accelerates an H{sup {minus}} pulsed beam coming out from RFQ at 2.5 MeV to 1000 MeV. They show a detailed transition from 402.5 MHz DTL with a 4 {beta}{lambda} structure to a CCDTL operated at 805 MHz with a 12 {beta}{lambda} structure. After a discussion of overall feature of the linac, they present an end-to-end particle simulation using the new version of the PARMILA code for a beam starting from the RFQ entrance through the rest of the linac. At 1000 MeV, the beam is transported to a storage ring. The storage ring requires a large ({+-}500-keV) energy spread. This is accomplished by operating the rf-phase in the last section of the linac so the particles are at the unstable fixed point of the separatrix. They present zero-current phase advance, beam size, and beam emittance along the entire linac.

  16. Theoretical aspects of implementation of kilovoltage cone-beam CT onboard linear accelerator for image-guided radiotherapy.

    Science.gov (United States)

    Rodríguez Cordón, Marta; Ferrer Albiach, Carlos

    2009-08-01

    The main objective of image-guided radiation therapy (IGRT) equipment is to reduce and correct inherent errors in external radiotherapy processes. At the present time, there are different IGRT systems available, but here we will refer exclusively to the kilovoltage cone-beam CT onboard linear accelerator (CBkVCT) and the different aspects that, from a clinical point of view, should be taken into consideration before the implementation of this equipment.

  17. Note: A pulsed laser ion source for linear induction accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, H., E-mail: bamboobbu@hotmail.com [Institute of Fluid Physics, China Academy of Engineering Physics, P.O. Box 919-106, Mianyang 621900 (China); School of Physics, Peking University, Beijing 100871 (China); Zhang, K.; Shen, Y.; Jiang, X.; Dong, P.; Liu, Y.; Wang, Y.; Chen, D.; Pan, H.; Wang, W.; Jiang, W.; Long, J.; Xia, L.; Shi, J.; Zhang, L.; Deng, J. [Institute of Fluid Physics, China Academy of Engineering Physics, P.O. Box 919-106, Mianyang 621900 (China)

    2015-01-15

    We have developed a high-current laser ion source for induction accelerators. A copper target was irradiated by a frequency-quadrupled Nd:YAG laser (266 nm) with relatively low intensities of 10{sup 8} W/cm{sup 2}. The laser-produced plasma supplied a large number of Cu{sup +} ions (∼10{sup 12} ions/pulse) during several microseconds. Emission spectra of the plasma were observed and the calculated electron temperature was about 1 eV. An induction voltage adder extracted high-current ion beams over 0.5 A/cm{sup 2} from a plasma-prefilled gap. The normalized beam emittance measured by a pepper-pot method was smaller than 1 π mm mrad.

  18. LAPACKrc: Fast linear algebra kernels/solvers for FPGA accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Juan; Nunez, Rafael C, E-mail: juan.gonzalez@accelogic.co [Accelogic, 1830 Main Street, Suite 204, Weston, FL (United States)

    2009-07-01

    We present LAPACKrc, a family of FPGA-based linear algebra solvers able to achieve more than 100x speedup per commodity processor on certain problems. LAPACKrc subsumes some of the LAPACK and ScaLAPACK functionalities, and it also incorporates sparse direct and iterative matrix solvers. Current LAPACKrc prototypes demonstrate between 40x-150x speedup compared against top-of-the-line hardware/software systems. A technology roadmap is in place to validate current performance of LAPACKrc in HPC applications, and to increase the computational throughput by factors of hundreds within the next few years.

  19. Assessment Of Some Acceleration Schemes In The Solution Of Systems Of Linear Equations.

    Directory of Open Access Journals (Sweden)

    S. Azizu

    2015-06-01

    Full Text Available Abstract In this paper assessment of acceleration schemes in the solution of systems of linear equations has been studied. The iterative methods Jacobi Gauss-Seidel and SOR methods were incorporated into the acceleration scheme Chebyshev extrapolation Residual smoothing Accelerated gradient and Richardson Extrapolation to speed up their convergence. The Conjugate gradient methods of GMRES BICGSTAB and QMR were also assessed. The research focused on Banded systems Tridiagonal systems and Dense Symmetric positive definite systems of linear equations for numerical experiments. The experiments were based on the following performance criteria convergence number of iterations speed of convergence and relative residual of each method. Matlab version 7.0.1 was used for the computation of the resulting algorithms. Assessment of the numerical results showed that the accelerated schemes improved the performance of Jacobi Gauss-Seidel and SOR methods. The Chebyshev and Richardson acceleration methods converged faster than the conjugate gradient methods of GMRES MINRES QMR and BICGSTAB in general.

  20. Linear Accelerator Test Facility at LNF Conceptual Design Report

    CERN Document Server

    Valente, Paolo; Bolli, Bruno; Buonomo, Bruno; Cantarella, Sergio; Ceccarelli, Riccardo; Cecchinelli, Alberto; Cerafogli, Oreste; Clementi, Renato; Di Giulio, Claudio; Esposito, Adolfo; Frasciello, Oscar; Foggetta, Luca; Ghigo, Andrea; Incremona, Simona; Iungo, Franco; Mascio, Roberto; Martelli, Stefano; Piermarini, Graziano; Sabbatini, Lucia; Sardone, Franco; Sensolini, Giancarlo; Ricci, Ruggero; Rossi, Luis Antonio; Rotundo, Ugo; Stella, Angelo; Strabioli, Serena; Zarlenga, Raffaele

    2016-01-01

    Test beam and irradiation facilities are the key enabling infrastructures for research in high energy physics (HEP) and astro-particles. In the last 11 years the Beam-Test Facility (BTF) of the DA{\\Phi}NE accelerator complex in the Frascati laboratory has gained an important role in the European infrastructures devoted to the development and testing of particle detectors. At the same time the BTF operation has been largely shadowed, in terms of resources, by the running of the DA{\\Phi}NE electron-positron collider. The present proposal is aimed at improving the present performance of the facility from two different points of view: extending the range of application for the LINAC beam extracted to the BTF lines, in particular in the (in some sense opposite) directions of hosting fundamental physics and providing electron irradiation also for industrial users; extending the life of the LINAC beyond or independently from its use as injector of the DA{\\Phi}NE collider, as it is also a key element of the electron/...

  1. Stereotactic radiosurgery for intracranial lesions using a linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Shoji, Kazufusa [Mie Univ., Tsu (Japan). School of Medicine; Toyota, Shun; Seta, Hidetoshi [and others

    1996-09-01

    Experiences in 47 cases of stereotactic radiosurgery were reported. The surgery was carried out using stereotactic radiosurgery system of Fisher STP system (Leibinger Co.). The accelerator was Clinac 2100c (Varian Co., 10 mV X ray) or EXL-15 SP (Mitsubishi Co., 6 mV) equipped with collimator. CT and MRI imaging data were firstly transported to the working station to determine the target volume, target coordinates and radiation dose. Irradiation from 90deg to -90deg directions from isocenter of the linac was done within an error of 1 mm after the actual measurement of the target on the port film. The treatment was necessary for 6-8 hr and and irradiation was essentially complete for it. The dose was 20 Gy for metastatic brain tumors (31 patients), 14-16 Gy for acoustic neuroma (1) and 16 Gy for arteriovenous malformation (1). The local control rate of the brain tumors was as high as 90%. The complication was cerebral necrosis (1 case) and exacerbation of neurological symptoms (1), which exhibited remission with steroid treatment. Thus stereotactic radiosurgery with linac made it possible to treat intracranial lesions without invasion effectively and safely. (K.H.)

  2. Recording Vavilov-Cherenkov radiation in a linear accelerator using a picosecond streak camera

    Science.gov (United States)

    Vorob'ev, N. S.; Gornostaev, P. B.; Gurov, S. M.; Dorokhov, V. L.; Zubko, A. E.; Lozovoi, V. I.; Meshkov, O. I.; Nikiforov, D. A.; Smirnov, A. V.; Shashkov, E. V.; Schelev, M. Ya

    2016-09-01

    Using a picosecond image converter camera with a linear sweep (PS-1/S1 streak camera developed at GPI RAS, Moscow), we have measured temporal parameters of Vavilov-Cherenkov radiation pulses. The radiation was generated by relativistic electrons passing through a quartz cone mounted on the axis of a vacuum chamber of a linear accelerator, which is a part of the VEPP-5 injection complex at the Budker Institute of Nuclear Physics, Siberian Branch of the Russian Academy of Sciences (BINP SB RAS, Novosibirsk). The data obtained in these experiments provide an insight into the processes of formation of electron bunches and their 'quality' in a linear accelerator prior to injection of electrons into the accumulator-cooler. A conclusion is made regarding the advisability of streak camera application in tuning the linear accelerators for optimisation of electron bunch parameters.

  3. Clinical Requirements and Accelerator Concepts for BNCT

    Science.gov (United States)

    Ludewigt, Bernhard A.

    1997-05-01

    Accelerator-driven epithermal neutron sources are an attractive alternative to nuclear reactors for Boron Neutron Capture Therapy (BNCT). In BNCT the goal of delivering a sufficient dose to the tumor without exceeding the dose limits of the surrounding normal tissues is achieved by administering a ^10B-containing compound which is selectively taken up in the tumor cells. Subsequent irradiation with epithermal neutrons leads to the release of short ranged (neutron-capture reaction. By carefully shaping the neutron spectrum the background dose, partially due to recoil protons and external gamma radiation, can be minimized and the depth dose distribution optimized. Excellent epithermal neutron beams for BNCT can be produced by bombarding a Li-target with a high current proton beam at energies ranging from the (p,n) reaction threshold to 2.5 MeV and subsequent moderation and filtering of the primary neutrons. In comparison the use of Be-targets and higher proton or deuteron energies, up to 20 MeV, leads to higher neutron yields but also to higher primary neutron energies requiring more moderation and resulting in less desirable neutron spectra. Accelerator options for possible neutron sources include dc-accelerators, RFQs, LINACs and cyclotrons. An electrostatic quadrupole (ESQ) accelerator has been chosen to provide a 2.5 MeV proton beam for the BNCT facility currently being designed at LBNL. An ESQ-accelerator is ideally suited to provide the high beam currents which are desired for producing high quality neutron beams for BNCT treatments. A novel power supply based on the air-coupled transformer concept is under development. It will enable the accelerator to deliver proton beam currents up to about 50 mA. A Li-target has been designed which can handle beam power in excess of 50 kW establishing the practicability of this approach. Monte Carlo simulation studies have shown that at a proton beam current of 20 mA high quality treatments for brain tumors can be delivered

  4. Acceleration tests of a 3 GHz proton linear accelerator (LIBO) for hadrontherapy

    Science.gov (United States)

    De Martinis, C.; Giove, D.; Amaldi, U.; Berra, P.; Crandall, K.; Mauri, M.; Weiss, M.; Zennaro, R.; Rosso, E.; Szeless, B.; Vretenar, M.; Masullo, M. R.; Vaccaro, V.; Calabretta, L.; Rovelli, A.

    2012-07-01

    This paper describes the acceleration tests performed at the Catania LNS Laboratory on a 3 GHz linac module of the side coupled type, which boosts the proton energy of a beam extracted from a cyclotron from 62 to 72 MeV. The output proton energy was measured with two devices: a NaI(Tl) crystal and a bending magnet. The experimental spectra are in good agreement with the calculated ones. From their shape it is obtained that (18±3.0)% of the transmitted protons fall in a ±2 MeV interval centered around 72 MeV. This result is in good agreement with the 20% value derived from the simulation of the acceleration process. The measured energy of the accelerated protons was used to check that the shunt impedance of the structure is equal to the computed one within 3%. This was the first time that a 3 GHz structure has been used to accelerate protons, and the results of the tests have demonstrated that a high frequency linac can be used as a cyclotron booster.

  5. Acceleration tests of a 3 GHz proton linear accelerator (LIBO) for hadrontherapy

    Energy Technology Data Exchange (ETDEWEB)

    De Martinis, C., E-mail: carlo.demartinis@mi.infn.it [University of Milan and INFN, Milan (Italy); Giove, D. [University of Milan and INFN, Milan (Italy); Amaldi, U.; Berra, P.; Crandall, K.; Mauri, M.; Weiss, M.; Zennaro, R. [TERA Foundation, Novara (Italy); Rosso, E.; Szeless, B.; Vretenar, M. [CERN, Geneva (Switzerland); Masullo, M.R.; Vaccaro, V. [University and INFN of Naples (Italy); Calabretta, L.; Rovelli, A. [INFN-LNS Catania (Italy)

    2012-07-21

    This paper describes the acceleration tests performed at the Catania LNS Laboratory on a 3 GHz linac module of the side coupled type, which boosts the proton energy of a beam extracted from a cyclotron from 62 to 72 MeV. The output proton energy was measured with two devices: a NaI(Tl) crystal and a bending magnet. The experimental spectra are in good agreement with the calculated ones. From their shape it is obtained that (18{+-}3.0)% of the transmitted protons fall in a {+-}2 MeV interval centered around 72 MeV. This result is in good agreement with the 20% value derived from the simulation of the acceleration process. The measured energy of the accelerated protons was used to check that the shunt impedance of the structure is equal to the computed one within 3%. This was the first time that a 3 GHz structure has been used to accelerate protons, and the results of the tests have demonstrated that a high frequency linac can be used as a cyclotron booster.

  6. A comparison of robotic arm versus gantry linear accelerator stereotactic body radiation therapy for prostate cancer.

    Science.gov (United States)

    Avkshtol, Vladimir; Dong, Yanqun; Hayes, Shelly B; Hallman, Mark A; Price, Robert A; Sobczak, Mark L; Horwitz, Eric M; Zaorsky, Nicholas G

    2016-01-01

    Prostate cancer is the most prevalent cancer diagnosed in men in the United States besides skin cancer. Stereotactic body radiation therapy (SBRT; 6-15 Gy per fraction, up to 45 minutes per fraction, delivered in five fractions or less, over the course of approximately 2 weeks) is emerging as a popular treatment option for prostate cancer. The American Society for Radiation Oncology now recognizes SBRT for select low- and intermediate-risk prostate cancer patients. SBRT grew from the notion that high doses of radiation typical of brachytherapy could be delivered noninvasively using modern external-beam radiation therapy planning and delivery methods. SBRT is most commonly delivered using either a traditional gantry-mounted linear accelerator or a robotic arm-mounted linear accelerator. In this systematic review article, we compare and contrast the current clinical evidence supporting a gantry vs robotic arm SBRT for prostate cancer. The data for SBRT show encouraging and comparable results in terms of freedom from biochemical failure (>90% for low and intermediate risk at 5-7 years) and acute and late toxicity (cancer-specific mortality) cannot be compared, given the indolent course of low-risk prostate cancer. At this time, neither SBRT device is recommended over the other for all patients; however, gantry-based SBRT machines have the abilities of treating larger volumes with conventional fractionation, shorter treatment time per fraction (~15 minutes for gantry vs ~45 minutes for robotic arm), and the ability to achieve better plans among obese patients (since they are able to use energies >6 MV). Finally, SBRT (particularly on a gantry) may also be more cost-effective than conventionally fractionated external-beam radiation therapy. Randomized controlled trials of SBRT using both technologies are underway.

  7. The clinical analysis of treatment of esophageal cancer of 222 cases with Cobalt-60 therapy unit and linear accelerator%钴-60机和加速器治疗食管癌222例临床分析

    Institute of Scientific and Technical Information of China (English)

    代培永; 袁胜利; 张春荣

    2013-01-01

    目的:探讨影响放射治疗食管癌疗效的常见因素。方法放射治疗食管癌222例,钴-60组与加速器组各111例,均采用常规分割照射。结果CR率钴-60与加速器组各为18.9%,31.5%。2a生存率钴-60与加速器组各为80.2%,90.1%。结论放射治疗食管癌应用加速器好于钴-60机,年轻患者、梗阻轻、无胸背痛及食管上段癌治疗效果较好。%Objective To analyze the factors influencing the effect of radiotherapy for esophageal carcinoma. Methods 111 cases among cobalt-60 or Accelerator group are treated by conventional radiotherapy. Results The 2-year survival rate in two groups were 80.2%,90.1%, respectively. Conclusion Radiotherapy for esophageal carcinoma with accelerator is more effective than with Cobalt-60 therapy unit .

  8. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'

    Science.gov (United States)

    Salter, Bill J.; Sarkar, Vikren; Wang, Brian; Shukla, Himanshu; Szegedi, Martin; Rassiah-Szegedi, Prema

    2011-04-01

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min-1) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  9. [Dosimetric characteristics of the bremsstrahlung beam from the LUE-15M medical linear electron accelerator].

    Science.gov (United States)

    Vatnitskiĭ, S M; Ermakov, I A; Puzanov, V P; Sinitsyn, R V; Cherviakov, A M

    1983-10-01

    The paper presents methods and results of a study of radiation-physical characteristics of inhibitory radiation beam with the Grenz energy of 15MeV generated by an electron linear accelerator LUE-15M. Special emphasis is laid on primary dosimetric information used for the planning of radiotherapy: depth doses, beam profiles, dose functions of a collimated beam. It has been shown that in general the accelerator meets the requirements of the International Electrotechnical Commission. General error in the focal absorbed dose at the expense of variable parameters of the accelerator was evaluated. It does not exceed +/- 3.5%.

  10. Investigation of linear accelerator pulse delivery using fast organic scintillator measurements

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Andersen, Claus Erik; Lindvold, Lars René;

    2010-01-01

    Fiber-coupled organic plastic scintillators present an attractive method for time-resolved dose measurements during radiotherapy. Most organic scintillators exhibit a fast response, making it possible to use them to measure individual high-energy X-ray pulses from a medical linear accelerator. Th...... performed on Varian medical linear accelerators, delivering 6 MV X-ray beams. The dose delivery per radiation pulse was found to agree with expectations within roughly 1%, although minor discrepancies and transients were evident in the measurements....

  11. Proposed Physics Experiments for Laser-Driven Electron Linear Acceleration in a Dielectric Loaded Vacuum, Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Byer, Robert L. [Stanford Univ., CA (United States). Dept. of Applied Physics. Edward L. Ginzton Lab.

    2016-07-08

    This final report summarizes the last three years of research on the development of advanced linear electron accelerators that utilize dielectric wave-guide vacuum channels pumped by high energy laser fields to accelerate beams of electrons.

  12. The MRI-Linear accelerator (MR-linac Consortium: evidence based clinical introduction of an innovation in radiation oncology connecting researchers, methodology, data collection, quality assurance and technical development

    Directory of Open Access Journals (Sweden)

    Linda G.W. Kerkmeijer

    2016-10-01

    Full Text Available An international research consortium has been formed to facilitate evidence-based introduction of MR-guided radiotherapy (MR-linac and to address how the MR-linac could be used to achieve an optimized radiation treatment approach to improve patients’ survival, local and regional tumor control, and quality of life. The present paper describes the organizational structure of the clinical part of the MR-linac consortium. Furthermore, it elucidates why collaboration on this large project is necessary and how a central data registry program will be implemented.

  13. Non-linear eye movements during visual-vestibular interaction under body oscillation with step-mode lateral linear acceleration.

    Science.gov (United States)

    Mori, Shigeo; Katayama, Naomi

    2005-02-01

    We investigated visual-vestibular interactions in normal humans, where a constant speed of optokinetic stimulation was combined with whole body oscillation of lateral linear acceleration (10 m stroke). The acceleration mode was not sinusoidal, but rectangular (step). The pure optokinetic reflex (reference OKR) and the OKR under combined stimulation (combined OKR) were induced by a random-dot pattern projected onto a hemispherical dome-screen affixed to a chair on a linear accelerator. The translational vestibulo-ocular reflex (tVOR) was determined separately in the dark during acceleration-step oscillation. Since the tVOR was masked by the OKR under combined stimulation, the interaction was assessed as changes in combined-OKR velocity at two segments of opposing acceleration; in other words, tVOR directions identical to (agonistic) and opposite to (antagonistic) the OKR direction. When a moderate optokinetic stimulus-speed of 40 deg/s was combined with a moderate acceleration of 0.3 G (3.0 m/s2) as in Experiment 1 (N=10), the combined-OKR velocity always increased during the agonistic condition, and the motion of the visual pattern was perceived as slow and clear in this segment. On the other hand, during the antagonistic condition, the combined-OKR velocity either remained unchanged or increased moderately, and the motion of the visual pattern was sensed as fast and unclear. Notably, in most subjects, the velocity difference in combined-OKR between the agonistic and antagonistic conditions was around the value of the tVOR velocity. In five of the ten subjects who completed an additional test session with the acceleration level increased from 0.3 to 0.5 G (4.9 m/s2), similar findings were maintained individually, suggesting independent behavior of tVOR. Therefore, we hypothesized that the interaction could be direction-selective; in other words, both tVOR and OKR are additive during the agonistic condition, but tVOR is suppressed during the antagonistic condition

  14. SU-E-T-136: Assessment of Seasonal Linear Accelerator Output Variations and Associated Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Bartolac, S; Letourneau, D [Princess Margaret Cancer Centre, Toronto, Ontario (Canada); University of Toronto, Toronto, Ontario (Canada)

    2015-06-15

    Purpose: Application of process control theory in quality assurance programs promises to allow earlier identification of problems and potentially better quality in delivery than traditional paradigms based primarily on tolerances and action levels. The purpose of this project was to characterize underlying seasonal variations in linear accelerator output that can be used to improve performance or trigger preemptive maintenance. Methods: Review of runtime plots of daily (6 MV) output data acquired using in house ion chamber based devices over three years and for fifteen linear accelerators of varying make and model were evaluated. Shifts in output due to known interventions with the machines were subtracted from the data to model an uncorrected scenario for each linear accelerator. Observable linear trends were also removed from the data prior to evaluation of periodic variations. Results: Runtime plots of output revealed sinusoidal, seasonal variations that were consistent across all units, irrespective of manufacturer, model or age of machine. The average amplitude of the variation was on the order of 1%. Peak and minimum variations were found to correspond to early April and September, respectively. Approximately 48% of output adjustments made over the period examined were potentially avoidable if baseline levels had corresponded to the mean output, rather than to points near a peak or valley. Linear trends were observed for three of the fifteen units, with annual increases in output ranging from 2–3%. Conclusion: Characterization of cyclical seasonal trends allows for better separation of potentially innate accelerator behaviour from other behaviours (e.g. linear trends) that may be better described as true out of control states (i.e. non-stochastic deviations from otherwise expected behavior) and could indicate service requirements. Results also pointed to an optimal setpoint for accelerators such that output of machines is maintained within set tolerances

  15. Development of high intensity linear accelerator for heavy ion inertial fusion driver

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Liang, E-mail: luliang@riken.jp [Institute of Modern Physics, 509 Nanchang Road, Lanzhou 730000 (China); Riken Nishina Center for Accelerator-Based Science, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Hattori, Toshiyuki [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-shi 263-8555 (Japan); Hayashizaki, Noriyosu [Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, N1-25 2-12-1 O-okayama, Meguro-ku, Tokyo 152-8550 (Japan); Ishibashi, Takuya [High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Okamura, Masahiro [Brookhaven National Laboratory, Upton, NY 11973 (United States); Kashiwagi, Hirotsugu [Japan Atomic Energy Research Institute, 1233 Watanuki-machi, Takasaki, Gunma 370-1292 (Japan); Takeuchi, Takeshi [Accelerator Engineering Corporation, 301, 6-18-1 Konakadai, Inage-ku, Chiba 263-0043 (Japan); Zhao, Hongwei; He, Yuan [Institute of Modern Physics, 509 Nanchang Road, Lanzhou 730000 (China)

    2013-11-21

    In order to verify the direct plasma injection scheme (DPIS), an acceleration test was carried out in 2001 using a radio frequency quadrupole (RFQ) heavy ion linear accelerator (linac) and a CO{sub 2}-laser ion source (LIS) (Okamura et al., 2002) [1]. The accelerated carbon beam was observed successfully and the obtained current was 9.22 mA for C{sup 4+}. To confirm the capability of the DPIS, we succeeded in accelerating 60 mA carbon ions with the DPIS in 2004 (Okamura et al., 2004; Kashiwagi and Hattori, 2004) [2,3]. We have studied a multi-beam type RFQ with an interdigital-H (IH) cavity that has a power-efficient structure in the low energy region. We designed and manufactured a two-beam type RFQ linac as a prototype for the multi-beam type linac; the beam acceleration test of carbon beams showed that it successfully accelerated from 5 keV/u up to 60 keV/u with an output current of 108 mA (2×54 mA/channel) (Ishibashi et al., 2011) [4]. We believe that the acceleration techniques of DPIS and the multi-beam type IH-RFQ linac are technical breakthroughs for heavy-ion inertial confinement fusion (HIF). The conceptual design of the RF linac with these techniques for HIF is studied. New accelerator-systems using these techniques for the HIF basic experiment are being designed to accelerate 400 mA carbon ions using four-beam type IH-RFQ linacs with DPIS. A model with a four-beam acceleration cavity was designed and manufactured to establish the proof of principle (PoP) of the accelerator.

  16. Development of an Automatic Frequency Control (AFC) System for RF Electron Linear Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Sungsu; Kim, Yujong; Lee, Byeong-No; Joo, Youngwoo; Lee, Soo Min; Lee, Byung Cheol; Cha, Hyungki [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Hyung Dal [Radiation Technology eXcellence, Daejeon (Korea, Republic of); Lee, Seung Hyun [Sungkyunkwan University, Suwon (Korea, Republic of)

    2015-10-15

    In this paper, the design, fabrication, and RF power test of the AFC system for the X-band linac are presented. The main function of the AFC system is automatically matching of the resonance frequency of the accelerating structure and the RF frequency of the magnetron. For the frequency tuning, a fine tuning of 10 kHz is possible by rotating the tuning shaft with a rotation of 0.72 degree per pulse. Therefore, the frequency deviation is about 0.01%, and almost full RF power (2.1 MW) transmission was obtained because the reflected power is minimized. The Radiation Equipment Research Division of the Korea Atomic Energy Research Institute has been developing and upgrading a medical/industrial X-band RF electron linear accelerators. The medical compact RF electron linear accelerator consists of an electron gun, an acceleration tube (accelerating structure), two solenoid magnets, two steering magnets, a magnetron, modulator, an automatic frequency control (AFC) system, and an X-ray generating target. The accelerating structure of the component is composed of oxygen-free high-conductivity copper (OFHC). Therefore, the volume of the structure, hence, its resonance frequency can easily be changeable if the ambient temperature and pressure are changed. If the RF frequency of the 9300 MHz magnetron and the resonance frequency of accelerating structure are not matched, performance of the structure can be degraded. An AFC system is automatically matched with the RF frequency of the magnetron and resonance frequency of the accelerating structure, which obtained a high output power and reliable accelerator operation.

  17. The neutron dose equivalent around high energy medical electron linear accelerators

    Directory of Open Access Journals (Sweden)

    Poje Marina

    2014-01-01

    Full Text Available The measurement of neutron dose equivalent was made in four dual energy linear accelerator rooms. Two of the rooms were reconstructed after decommissioning of 60Co units, so the main limitation was the space. The measurements were performed by a nuclear track etched detectors LR-115 associated with the converter (radiator that consist of 10B and with the active neutron detector Thermo BIOREM FHT 742. The detectors were set at several locations to evaluate the neutron ambient dose equivalent and/or neutron dose rate to which medical personnel could be exposed. Also, the neutron dose dependence on collimator aperture was analyzed. The obtained neutron dose rates outside the accelerator rooms were several times smaller than the neutron dose rates inside the accelerator rooms. Nevertheless, the measured neutron dose equivalent was not negligible from the aspect of the personal dosimetry with almost 2 mSv a year per person in the areas occupied by staff (conservative estimation. In rooms with 15 MV accelerators, the neutron exposure to the personnel was significantly lower than in the rooms having 18 MV accelerators installed. It was even more pronounced in the room reconstructed after the 60Co decommissioning. This study confirms that shielding from the neutron radiation should be considered when building vaults for high energy linear accelerators, especially when the space constraints exist.

  18. Stanford Linear Accelerator Center selects Verity Ultraseek for public and internal Web Sites

    CERN Multimedia

    2004-01-01

    Verity Inc., a provider of enterprise software has announced the latest version of its powerful, downloadable Verity(R) Ultraseek(R) enterprise search engine is being used by the Stanford Linear Accelerator Center, a research facility funded by the U.S. Department of Energy and operated by Stanford University (1/2 page).

  19. DZ-12/4 Multi-energy Electron Linear Accelerator Acceptance Test

    Institute of Scientific and Technical Information of China (English)

    XIA; Wen; YE; Hong-sheng; ZHANG; Wei-dong; CHEN; Yi-zhen; LIN; Min; XU; Li-jun; CHEN; Ke-sheng; LI; Ming

    2015-01-01

    DZ-12/4multi-energy electron linear accelerator device established by China Institute of Atomic Energy can provide 6 MeV,8 MeV,10MeV,12MeV electron energy beam,mainly used to establish electron beam reference radiation fields of radiation processing dose level,and

  20. Efficient SAT engines for concise logics: Accelerating proof search for zero-one linear constraint systems

    DEFF Research Database (Denmark)

    Fränzle, Martin; Herde, Christian

    2003-01-01

    We investigate the problem of generalizing acceleration techniques as found in recent satisfiability engines for conjunctive normal forms (CNFs) to linear constraint systems over the Booleans. The rationale behind this research is that rewriting the propositional formulae occurring in e.g. bounde...

  1. Head linear and rotational accelerations and craniocervical loads in lateral impact

    NARCIS (Netherlands)

    Yoganandan, N.; Pintar, F.A.; Maiman, D.; Phillippens, M.M.G.M.; Wismans, J.S.H.M.

    2006-01-01

    The objective of the study was to determine lateral impact-induced three-dimensional temporal head center of gravity linear and angular accelerations, and craniocervical forces and moments from post mortem human subject (PMHS) sled tests and compare with the European side impact dummy, ES-II, respon

  2. Third party EPID with IGRT capability retrofitted onto an existing medical linear accelerator.

    Science.gov (United States)

    Odero, D O; Shimm, D S

    2009-07-01

    Radiation therapy requires precision to avoid unintended irradiation of normal organs. Electronic Portal Imaging Devices (EPIDs), can help with precise patient positioning for accurate treatment. EPIDs are now bundled with new linear accelerators, or they can be purchased from the Linac manufacturer for retrofit. Retrofitting a third party EPID to a linear accelerator can pose challenges. The authors describe a relatively inexpensive third party CCD camera-based EPID manufactured by TheraView (Cablon Medical B.V.), installed onto a Siemens Primus linear accelerator, and integrated with a Lantis record and verify system, an Oldelft simulator with Digital Therapy Imaging (DTI) unit, and a Philips ADAC Pinnacle treatment planning system (TPS). This system integrates well with existing equipment and its software can process DICOM images from other sources. The system provides a complete imaging system that eliminates the need for separate software for portal image viewing, interpretation, analysis, archiving, image guided radiation therapy and other image management applications. It can also be accessed remotely via safe VPN tunnels. TheraView EPID retrofit therefore presents an example of a less expensive alternative to linear accelerator manufacturers' proprietary EPIDs suitable for implementation in third world countries radiation therapy departments which are often faced with limited financial resources.

  3. Experimental confirmation of transverse focusing and adiabatic damping in a standing wave linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Reiche, S.; Rosenzweig, J.B.; Anderson, S.; Frigola, P.; Hogan, M.; Murokh, A.; Pellegrini, C.; Serafini, L.; Travish, G.; Tremaine, A. [Department of Physics and Astronomy, University of California, Los Angeles, Los Angeles, California 90095-1547 (United States)

    1997-09-01

    The measurement of the transverse phase-space map, or transport matrix, of a relativistic electron in a high-gradient, radio-frequency linear accelerator (rf linac) at the UCLA photoinjector is reported. This matrix, which indicates the effects of acceleration (adiabatic damping), first-order transient focusing, and ponderomotive second-order focusing, is measured as a function of both rf field amplitude and phase in the linac. The elements of the matrix, determined by observation of centroid motion at a set of downstream diagnostics due to deflections induced by a set of upstream steering magnets, compare well with previously developed analytical theory [J. Rosenzweig and L. Serafini, Phys. Rev. E {bold 49}, 1599 (1994)]. The determinant of the matrix is obtained, yielding a direct confirmation of trace space adiabatic damping. Implications of these results on beam optics at moderate energy in high-gradient linear accelerators such as rf photoinjectors are discussed. {copyright} {ital 1997} {ital The American Physical Society}

  4. ARIEL e-linac. Electron linear accelerator for photo-fission

    Science.gov (United States)

    Koscielniak, Shane

    2014-01-01

    The design and implementation of a 1/2 MW beam power electron linear accelerator (e-linac) for the production of rare isotope beams (RIB) via photo-fission in the context of the Advanced Rare IsotopE Laboratory, ARIEL (Koscielniak et al. 2008; Merminga et al. 2011; Dilling et al., Hyperfine Interact, 2013), is described. The 100 % duty factor e-linac is based on super-conducting radiofrequency (SRF) technology at 1.3 GHz and has a nominal energy of 50 MeV. This paper provides an overview of the accelerator major components including the gun, cryomodules and cryoplant, high power RF sources, and machine layout including beam lines. Design features to facilitate operation of the linac as a Recirculating Linear Accelerator (RLA) for various applications, including Free Electron Lasers, are also noted.

  5. Energy shaping non-linear acceleration control for a pendulum-type mobility and experimental verification

    Science.gov (United States)

    Yokoyama, Kazuto; Takahashi, Masaki

    2015-02-01

    A dynamics-based non-linear controller with energy shaping to accelerate a pendulum-type mobility is proposed. The concept of this study is to control translational acceleration of the vehicle in a dynamically reasonable manner. The body angle is controlled to maintain a reference state where the vehicle is statically unstable but dynamically stable, which leads to a constant translational acceleration due to instability of the system. The accelerating motion is like a sprinter moving from crouch start and it fully exploits dynamics of the vehicle. To achieve it, the total energy of the system is shaped to have the minimum at a given reference state and the system is controlled to converge to it. The controller can achieve various properties through the energy shaping procedure. Especially, an energy function that will lead to safe operation of the vehicle is proposed. The effectiveness of the controller is verified in simulations and experiments.

  6. Prototyping a large field size IORT applicator for a mobile linear accelerator

    Science.gov (United States)

    Janssen, Rogier W. J.; Faddegon, Bruce A.; Dries, Wim J. F.

    2008-04-01

    The treatment of large tumors such as sarcomas with intra-operative radiotherapy using a Mobetron® is often complicated because of the limited field size of the primary collimator and the available applicators (max Ø100 mm). To circumvent this limitation a prototype rectangular applicator of 80 × 150 mm2 was designed and built featuring an additional scattering foil located at the top of the applicator. Because of its proven accuracy in modeling linear accelerator components the design was based on the EGSnrc Monte Carlo simulation code BEAMnrc. First, the Mobetron® treatment head was simulated both without an applicator and with a standard 100 mm applicator. Next, this model was used to design an applicator foil consisting of a rectangular Al base plate covering the whole beam and a pyramid of four stacked cylindrical slabs of different diameters centered on top of it. This foil was mounted on top of a plain rectangular Al tube. A prototype was built and tested with diode dosimetry in a water tank. Here, the prototype showed clinically acceptable 80 × 150 mm2 dose distributions for 4 MeV, 6 MeV and 9 MeV, obviating the use of complicated multiple irradiations with abutting field techniques. In addition, the measurements agreed well with the MC simulations, typically within 2%/1 mm.

  7. A comparison of robotic arm versus gantry linear accelerator stereotactic body radiation therapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Avkshtol V

    2016-08-01

    Full Text Available Vladimir Avkshtol, Yanqun Dong, Shelly B Hayes, Mark A Hallman, Robert A Price, Mark L Sobczak, Eric M Horwitz,* Nicholas G Zaorsky* Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, USA *These authors contributed equally to this work Abstract: Prostate cancer is the most prevalent cancer diagnosed in men in the United States besides skin cancer. Stereotactic body radiation therapy (SBRT; 6–15 Gy per fraction, up to 45 minutes per fraction, delivered in five fractions or less, over the course of approximately 2 weeks is emerging as a popular treatment option for prostate cancer. The American Society for Radiation Oncology now recognizes SBRT for select low- and intermediate-risk prostate cancer patients. SBRT grew from the notion that high doses of radiation typical of brachytherapy could be delivered noninvasively using modern external-beam radiation therapy planning and delivery methods. SBRT is most commonly delivered using either a traditional gantry-mounted linear accelerator or a robotic arm-mounted linear accelerator. In this systematic review article, we compare and contrast the current clinical evidence supporting a gantry vs robotic arm SBRT for prostate cancer. The data for SBRT show encouraging and comparable results in terms of freedom from biochemical failure (>90% for low and intermediate risk at 5–7 years and acute and late toxicity (<6% grade 3–4 late toxicities. Other outcomes (eg, overall and cancer-specific mortality cannot be compared, given the indolent course of low-risk prostate cancer. At this time, neither SBRT device is recommended over the other for all patients; however, gantry-based SBRT machines have the abilities of treating larger volumes with conventional fractionation, shorter treatment time per fraction (~15 minutes for gantry vs ~45 minutes for robotic arm, and the ability to achieve better plans among obese patients (since they are able to use energies >6 MV. Finally

  8. Radiosurgery with a linear accelerator in cerebral arteriovenous malformations Radiocirurgia com acelerador linear em malformações arteriovenosas cerebrais

    Directory of Open Access Journals (Sweden)

    Sérgio Carlos Barros Esteves

    2008-04-01

    Full Text Available OBJECTIVE: To evaluate results achieved with radiosurgery and complications of the procedure when treating arteriovenous malformations with linear accelerator. METHODS: This retrospective study was conducted between October 1993 and December 1996. Sixty-one patients with arteriovenous malformations were treated with radiosurgery utilizing a 6MV energy linear accelerator. Ages of the 32 female and 29 male patients ranged from 6 to 54 years (mean: 28.3 years. The most frequent initial symptom was cephalea (45.9%, followed by neurological deficit (36.1%. Cerebral hemorrhage diagnosed by image was observed in 35 patients (57.3%. Most arteriovenous malformations (67.2% were graded Spetzler III and IV. Venous stenosis (21.3% and aneurysm (13.1% were the most frequent angioarchitecture changes. The dose administered varied from 12 to 27.5Gy in the periphery of the lesion. RESULTS: Out of twenty-eight patients that underwent conclusive angiography control, complete obliteration was achieved in 18 (72% and treatment failed in 7 (absence of occlusion with more than 3 years of follow-up. Four were submitted to a second radiosurgery, and one of these has shown obliteration after 18 months of follow-up. DISCUSSION: Several factors were analyzed regarding the occlusion rate (gender, age, volume, localization, Spetzler, flow, embolization, total of isocenters, prescribed dose and chosen isodose and complications (total of isocenters, localization, volume, maximum dose, prescribed dose and chosen isodose. Analyzed variables showed no statistical significance for obliteration of the vessel, as well as for treatment complications. The largest diameter of the arteriovenous malformation, its volume and the dose administered did not influence time of obliteration. CONCLUSION: Radiosurgery is effective in the treatment of arteriovenous malformations and can be an alternative for patients with clinical contraindication or with lesions in eloquent areas. In the studied

  9. Fast and dynamic generation of linear octrees for geological bodies under hardware acceleration

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    In the application of 3D Geoscience Modeling,we often need to generate the volumetric representations of geological bodies from their surface representations.Linear octree,as an efficient and easily operated volumetric model,is widely used in 3D Geoscience Modeling.This paper proposes an algorithm for fast and dynamic generation of linear octrees of geological bodies from their surface models under hardware acceleration.The Z-buffers are used to determine the attributes of octants and voxels in a fast way,and a divide-and-conquer strategy is adopted.A stack structure is exploited to record the subdivision,which allows generating linear octrees dynamically.The algorithm avoids large-scale sorting process and bypasses the compression in linear octrees generation.Experimental results indicate its high efficiency in generating linear octrees for large-scale geologic bodies.

  10. Calibration of an Electron Linear Accelerator using an acrylic puppet; Calibracion de un Acelerador Lineal de Electrones usando maniqui de acrilico

    Energy Technology Data Exchange (ETDEWEB)

    Guzman C, C.S.; Picon C, C. [Instituto de Enfermedades Neoplasicas, Departamento de Radioterapia-Servicio de Fisica, Av. Angamos 2520, Lima 34 (Peru)

    1998-12-31

    The finality of this work is to find the dose for electron beams using acrylic puppets and inter comparing with the measurements in water, found also its respective conversion factor. With base in this, its may be realize interesting measurements for the good performance of a linear accelerator and special clinical treatments in less time. (Author)

  11. The Gent University 15 MeV high-current linear electron accelerator facility

    Science.gov (United States)

    Mondelaers, W.; Van Laere, K.; Goedefroot, A.; Van den Bossche, K.

    1996-01-01

    The Gent University 15 MeV 20kW linear electron accelerator facility was initially designed for fundamental nuclear physics research. During the last years a large effort has been devoted to the expansion of the range of machine applications in view of a new extensive experimental programme in the fields of atomic and solid-state physics, biomaterials research, polymer chemistry, space research, food technology, high-dose dosimetry and radiation therapy. The accelerator facility in its present configuration, the peripheral equipment and the experimental programme are described with emphasis on the original features.

  12. The Experimental Study of Rayleigh-Taylor Instability using a Linear Induction Motor Accelerator

    Science.gov (United States)

    Yamashita, Nicholas; Jacobs, Jeffrey

    2009-11-01

    The experiments to be presented utilize an incompressible system of two stratified miscible liquids of different densities that are accelerated in order to produce the Rayleigh-Taylor instability. Three liquid combinations are used: isopropyl alcohol with water, a calcium nitrate solution or a lithium polytungstate solution, giving Atwood numbers of 0.11, 0.22 and 0.57, respectively. The acceleration required to drive the instability is produced by two high-speed linear induction motors mounted to an 8 m tall drop tower. The motors are mounted in parallel and have an effective acceleration length of 1.7 m and are each capable of producing 15 kN of thrust. The liquid system is contained within a square acrylic tank with inside dimensions 76 x76x184 mm. The tank is mounted to an aluminum plate, which is driven by the motors to create constant accelerations in the range of 1-20 g's, though the potential exists for higher accelerations. Also attached to the plate are a high-speed camera and an LED backlight to provide continuous video of the instability. In addition, an accelerometer is used to provide acceleration measurements during each experiment. Experimental image sequences will be presented which show the development of a random three-dimensional instability from an unforced initial perturbation. Measurements of the mixing zone width will be compared with traditional growth models.

  13. The vestibular evoked response to linear, alternating, acceleration pulses without acoustic masking as a parameter of vestibular function

    NARCIS (Netherlands)

    Oei, MLYM; Segenhout, JM; Wit, HP; Albers, FWJ

    2001-01-01

    In this study, short latency vestibular evoked potentials (VsEPs) were recorded in five guinea pigs in response to alternating linear acceleration pulses with and without acoustic masking. A steel bolt was implanted in the skull and coupled to a shaker. Linear acceleration pulses (n = 400) in upward

  14. [Evaluation of a risk communication approach for maintenance staff working with induced radioactivity in medical linear accelerators].

    Science.gov (United States)

    Watanabe, Hiroshi; Yamaguchi, Ichiro; Maehara, Yoshiaki; Koizumi, Mitsue; Fujibuchi, Toshioh; Kida, Tetsuo; Tsukamoto, Atsuko; Horitsugi, Genki; Hiraki, Hitoshi; Kimura, Yumi; Oyama, Masaya

    2013-12-01

    In order to promote consensus building on decommissioning operation rules for medical linear accelerators in Japan, we carried out a risk communication (RC) approach mainly providing knowledge for maintenance staff regarding induced radioactivity. In February 2012, we created a booklet (26 pages) to present an overview of the amended law, the mechanism and the distribution of induced radioactivity showing the actual radiation dose rate around a linear accelerator and actual exposure doses to staff. In addition, we co-sponsored a seminar for workers in this field organized by the Japan Medical Imaging and Radiological Systems Industries Association to explain the contents of this booklet, and answer questions regarding induced radioactivity of linear accelerators as an RC program. As a result, the understanding of staff regarding the regulations on maximum X-ray energy on linear accelerators (Papproach suggests that consensus building should be used to make rules on decommissioning operations for linear medical accelerators.

  15. Survey and Alignment of the 100MeV Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Park, Bumsik; Kwon, Hyeokjung; Jang, Jiho; Kim, Hansung; Kim, Daeil; Cho, Yongsub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The 100MeV linear accelerator was installed and under commissioning at the Gyeongju site. The 100MeV proton linac was developed by the KOMAC according to the survey work and the alignment process. 100MeV proton beam will be supplied to the users after the beam commissioning. KOMAC is developing a 100MeV high-duty-factor proton linac. Linac is composed with a 50keV proton injector, a 3MeV RFQ, DTL tanks and a beam dump. In this paper, the survey and alignment scheme are described. To install the accelerator, the align network was built and the survey work was accomplished. On the basis of the survey result, all of the accelerator components were installed in the tunnel with two laser trackers.

  16. The Fast Linear Accelerator Modeling Engine for FRIB Online Model Service

    CERN Document Server

    He, Z; Davidsaver, M; Fukushima, K; Shen, G; Ikegami, M

    2016-01-01

    Commissioning of a large accelerator facility like FRIB needs support from an online beam dynamics model. Considering the new physics challenges of FRIB such as modeling of non-axisymmetric superconducting RF cavities and multi-charge state acceleration, there is no readily available online beam tuning code. The design code of FRIB super-conducting linac, IMPACT-Z, is not suitable for online tuning because of its code design and running speed. Therefore, the Fast Linear Accelerator Modeling Engine (FLAME), specifically designed to fulfill FRIB's online modeling challenges, is proposed. The physics model of FLAME, especially its novel way of modeling non-axisymmetric superconducting RF cavities using a multipole expansion based thin-lens kick model, is discussed in detail, and the benchmark results against FRIB design code is presented, after which the software design strategy of FLAME and its execution speed is presented.

  17. Proceedings of the conference on computer codes and the linear accelerator community

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.K. (comp.)

    1990-07-01

    The conference whose proceedings you are reading was envisioned as the second in a series, the first having been held in San Diego in January 1988. The intended participants were those people who are actively involved in writing and applying computer codes for the solution of problems related to the design and construction of linear accelerators. The first conference reviewed many of the codes both extant and under development. This second conference provided an opportunity to update the status of those codes, and to provide a forum in which emerging new 3D codes could be described and discussed. The afternoon poster session on the second day of the conference provided an opportunity for extended discussion. All in all, this conference was felt to be quite a useful interchange of ideas and developments in the field of 3D calculations, parallel computation, higher-order optics calculations, and code documentation and maintenance for the linear accelerator community. A third conference is planned.

  18. Characterization of the neutron for linear accelerator shielding wall using a Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yeon [Dept. of Radiation Oncology, Dongnam Inst. of Radiological and Medical Science, Busan (Korea, Republic of); Park, Eun Tae [Dept. of Radiation Oncology, Inje University Busan Paik Hospital, Busan (Korea, Republic of); Kim, Jung Hoon [Dept. of Radiologic Science, College of Health Sciences, Catholic University of Pusan, Busan (Korea, Republic of)

    2016-03-15

    As previous studies to proceed with the evaluation of the radioactive at linear accelerator's shielding concrete wall. And the shielding wall was evaluated the characteristics for the incoming neutron. As a result, the shielding wall is the average amount of incoming neutrons 10 MV 4.63E-7%, 15 MV 9.69E-6%, showed the occurrence of 20 MV 2.18E-5%. The proportion of thermal neutrons of which are found to be approximately 18-33%. The neutron generation rate can be seen as a slight numerical order. However, in consideration of the linear accelerator operating time we can not ignore the effects of neutrons. Accordingly radioactive problem of the radiation shield wall of the treatment room will be this should be considered.

  19. The R&D Works on the High Intensity Proton Linear Accelerator for Nuclear Waste Transmutation

    CERN Document Server

    Ito, N; Ino, H; Kawai, M; Kusano, J; Mizumoto, M; Murata, H; Oguri, H; Okumura, Y; Touchi, Y

    1996-01-01

    The R&D works of the 10MeV/10mA proton linear accelerator have been carried out for last four years. A high brightness hydrogen ion source, an RFQ and an RF power source have been developed and examined to achieve 2MeV proton beam. A DTL hot test model was also fabricated and a high power test has been carried out. The present status of the R&D works are described in this paper.

  20. Complications following linear accelerator based stereotactic radiation for cerebral arteriovenous malformations

    DEFF Research Database (Denmark)

    Skjøth-Rasmussen, Jane; Roed, Henrik; Ohlhues, Lars;

    2010-01-01

    Primarily, gamma knife centers are predominant in publishing results on arteriovenous malformations (AVM) treatments including reports on risk profile. However, many patients are treated using a linear accelerator-most of these at smaller centers. Because this setting is different from a large...... gamma knife center, the risk profile at Linac departments could be different from the reported experience. Prescribed radiation doses are dependent on AVM volume. This study details results from a medium sized Linac department center focusing on risk profiles....

  1. Towards radiation pressure acceleration of protons using linearly polarized ultrashort petawatt laser pulses

    CERN Document Server

    Kim, I Jong; Kim, Chul Min; Kim, Hyung Taek; Sung, Jae Hee; Lee, Seong Ku; Yu, Tae Jun; Choi, Il Woo; Lee, Chang-Lyoul; Nam, Kee Hwan; Nickles, Peter V; Jeong, Tae Moon; Lee, Jongmin

    2013-01-01

    Particle acceleration using ultraintense, ultrashort laser pulses is one of the most attractive topics in relativistic laser-plasma research. We report proton/ion acceleration in the intensity range of 5x1019 W/cm2 to 3.3x1020 W/cm2 by irradiating linearly polarized, 30-fs, 1-PW laser pulses on 10- to 100-nm-thick polymer targets. The proton energy scaling with respect to the intensity and target thickness was examined. The experiments demonstrated, for the first time with linearly polarized light, a transition from the target normal sheath acceleration to radiation pressure acceleration and showed a maximum proton energy of 45 MeV when a 10-nm-thick target was irradiated by a laser intensity of 3.3x1020 W/cm2. The experimental results were further supported by two- and three-dimensional particle-in-cell simulations. Based on the deduced proton energy scaling, proton beams having an energy of ~ 200 MeV should be feasible at a laser intensity of 1.5x1021 W/cm2.

  2. FLUKA Monte Carlo for Basic Dosimetric Studies of Dual Energy Medical Linear Accelerator

    Directory of Open Access Journals (Sweden)

    K. Abdul Haneefa

    2014-01-01

    Full Text Available General purpose Monte Carlo code for simulation of particle transport is used to study the basic dosimetric parameters like percentage depth dose and dose profiles and compared with the experimental measurements from commercial dual energy medical linear accelerator. Varian Clinac iX medical linear accelerator with dual energy photon beams (6 and 15 MV is simulated using FLUKA. FLAIR is used to visualize and edit the geometry. Experimental measurements are taken for 100 cm source-to-surface (SSD in 50 × 50 × 50 cm3 PTW water phantom using 0.12 cc cylindrical ionization chamber. Percentage depth dose for standard square field sizes and dose profiles for various depths are studied in detail. The analysis was carried out using ROOT (a DATA analysis frame work developed at CERN system. Simulation result shows good agreement in percentage depth dose and beam profiles with the experimental measurements for Varian Clinac iX dual energy medical linear accelerator.

  3. Control of Switching Characteristics of Silicon-based Semiconductor Diode Using High Energy Linear Accelerator

    Directory of Open Access Journals (Sweden)

    N. Harihara Krishnan

    2013-05-01

    Full Text Available This paper reports control of switching characteristics of silicon-based semiconductor diode using electron beam produced using linear accelerator. Conventionally, p-n junction chips of diode are exposed to gamma rays from a radioactive source or electron beam from a microtron, depending upon the required level of correction. High energy linear accelerators featuring simultaneous exposure of multiple chips are recent advancements in radiation technology. The paper presents the results of the radiation process using a 10 MeV linear accelerator as applied in industrial manufacturing of a high voltage diode (2600 V. The achieved values of reverse recovery time were found to be within the design limits. The suitability of the new process was verified by constructing the trade-off curve between the switching and conduction parameters of the diode for the complete range using large number of experimental samples. The paper summarizes the advantages of the new process over the conventional methods specifically with reference to industrial requirements. The developed process has been successfully implemented in semiconductor manufacturing.

  4. Automating quality assurance of digital linear accelerators using a radioluminescent phosphor coated phantom and optical imaging

    Science.gov (United States)

    Jenkins, Cesare H.; Naczynski, Dominik J.; Yu, Shu-Jung S.; Yang, Yong; Xing, Lei

    2016-09-01

    Performing mechanical and geometric quality assurance (QA) tests for medical linear accelerators (LINAC) is a predominantly manual process that consumes significant time and resources. In order to alleviate this burden this study proposes a novel strategy to automate the process of performing these tests. The autonomous QA system consists of three parts: (1) a customized phantom coated with radioluminescent material; (2) an optical imaging system capable of visualizing the incidence of the radiation beam, light field or lasers on the phantom; and (3) software to process the captured signals. The radioluminescent phantom, which enables visualization of the radiation beam on the same surface as the light field and lasers, is placed on the couch and imaged while a predefined treatment plan is delivered from the LINAC. The captured images are then processed to self-calibrate the system and perform measurements for evaluating light field/radiation coincidence, jaw position indicators, cross-hair centering, treatment couch position indicators and localizing laser alignment. System accuracy is probed by intentionally introducing errors and by comparing with current clinical methods. The accuracy of self-calibration is evaluated by examining measurement repeatability under fixed and variable phantom setups. The integrated system was able to automatically collect, analyze and report the results for the mechanical alignment tests specified by TG-142. The average difference between introduced and measured errors was 0.13 mm. The system was shown to be consistent with current techniques. Measurement variability increased slightly from 0.1 mm to 0.2 mm when the phantom setup was varied, but no significant difference in the mean measurement value was detected. Total measurement time was less than 10 minutes for all tests as a result of automation. The system’s unique features of a phosphor-coated phantom and fully automated, operator independent self-calibration offer the

  5. Design and test of a superconducting magnet in a linear accelerator for an Accelerator Driven Subcritical System

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Quanling, E-mail: pengql@ihep.ac.cn [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Xu, Fengyu [Harbin Institute of Technology, Heilongjiang 150006 (China); Wang, Ting [Beijing Huantong Special Equipment Co., LTD, Beijing 100192 (China); Yang, Xiangchen [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chen, Anbin [Harbin Institute of Technology, Heilongjiang 150006 (China); Wei, Xiaotao [Beijing Huantong Special Equipment Co., LTD, Beijing 100192 (China); Gao, Yao; Hou, Zhenhua; Wang, Bing; Chen, Yuan; Chen, Haoshu [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2014-11-11

    A batch superconducting solenoid magnet for the ADS proton linear accelerator has been designed, fabricated, and tested in a vertical dewar in Sept. 2013. A total of ten superconducting magnets will be installed into two separate cryomodules. Each cryomodule contains six superconducting spoke RF cavities for beam acceleration and five solenoid magnets for beam focusing. The multifunction superconducting magnet contains a solenoid for beam focusing and two correctors for orbit correction. The design current for the solenoid magnet is 182 A. A quench performance test shows that the operating current of the solenoid magnet can reach above 300 A after natural quenching on three occasions during current ramping (260 A, 268 A, 308 A). The integrated field strength and leakage field at the nearby superconducting spoke cavities all meet the design requirements. The vertical test checked the reliability of the test dewar and the quench detection system. This paper presents the physical and mechanical design of the batch magnets, the quench detection technique, field measurements, and a discussion of the residual field resulting from persistent current effects.

  6. Accelerated solution of non-linear flow problems using Chebyshev iteration polynomial based RK recursions

    Energy Technology Data Exchange (ETDEWEB)

    Lorber, A.A.; Carey, G.F.; Bova, S.W.; Harle, C.H. [Univ. of Texas, Austin, TX (United States)

    1996-12-31

    The connection between the solution of linear systems of equations by iterative methods and explicit time stepping techniques is used to accelerate to steady state the solution of ODE systems arising from discretized PDEs which may involve either physical or artificial transient terms. Specifically, a class of Runge-Kutta (RK) time integration schemes with extended stability domains has been used to develop recursion formulas which lead to accelerated iterative performance. The coefficients for the RK schemes are chosen based on the theory of Chebyshev iteration polynomials in conjunction with a local linear stability analysis. We refer to these schemes as Chebyshev Parameterized Runge Kutta (CPRK) methods. CPRK methods of one to four stages are derived as functions of the parameters which describe an ellipse {Epsilon} which the stability domain of the methods is known to contain. Of particular interest are two-stage, first-order CPRK and four-stage, first-order methods. It is found that the former method can be identified with any two-stage RK method through the correct choice of parameters. The latter method is found to have a wide range of stability domains, with a maximum extension of 32 along the real axis. Recursion performance results are presented below for a model linear convection-diffusion problem as well as non-linear fluid flow problems discretized by both finite-difference and finite-element methods.

  7. X-ray beam hardening correction for measuring density in linear accelerator industrial computed tomography

    Institute of Scientific and Technical Information of China (English)

    ZHOU Ri-Feng; WANG Jue; CHEN Wei-Min

    2009-01-01

    Due to X-ray attenuation being approximately proportional to material density, it is possible to measure the inner density through Industrial Computed Tomography (ICT) images accurately. In practice, however, a number of factors including the non-linear effects of beam hardening and diffuse scattered radia-tion complicate the quantitative measurement of density variations in materials. This paper is based on the linearization method of beam hardening correction, and uses polynomial fitting coefficient which is obtained by the curvature of iron polychromatic beam data to fit other materials. Through theoretical deduction, the paper proves that the density measure error is less than 2% if using pre-filters to make the spectrum of linear accelerator range mainly 0.3 MeV to 3 MeV. Experiment had been set up at an ICT system with a 9 MeV electron linear accelerator. The result is satisfactory. This technique makes the beam hardening correction easy and simple, and it is valuable for measuring the ICT density and making use of the CT images to recognize materials.

  8. Acceleration of multiple solution of a boundary value problem involving a linear algebraic system

    Science.gov (United States)

    Gazizov, Talgat R.; Kuksenko, Sergey P.; Surovtsev, Roman S.

    2016-06-01

    Multiple solution of a boundary value problem that involves a linear algebraic system is considered. New approach to acceleration of the solution is proposed. The approach uses the structure of the linear system matrix. Particularly, location of entries in the right columns and low rows of the matrix, which undergo variation due to the computing in the range of parameters, is used to apply block LU decomposition. Application of the approach is considered on the example of multiple computing of the capacitance matrix by method of moments used in numerical electromagnetics. Expressions for analytic estimation of the acceleration are presented. Results of the numerical experiments for solution of 100 linear systems with matrix orders of 1000, 2000, 3000 and different relations of variated and constant entries of the matrix show that block LU decomposition can be effective for multiple solution of linear systems. The speed up compared to pointwise LU factorization increases (up to 15) for larger number and order of considered systems with lower number of variated entries.

  9. Effects of Frequency and Motion Paradigm on Perception of Tilt and Translation During Periodic Linear Acceleration

    Science.gov (United States)

    Beaton, K. H.; Holly, J. E.; Clement, G. R.; Wood, Scott J.

    2009-01-01

    Previous studies have demonstrated an effect of frequency on the gain of tilt and translation perception. Results from different motion paradigms are often combined to extend the stimulus frequency range. For example, Off-Vertical Axis Rotation (OVAR) and Variable Radius Centrifugation (VRC) are useful to test low frequencies of linear acceleration at amplitudes that would require impractical sled lengths. The purpose of this study was to compare roll-tilt and lateral translation motion perception in 12 healthy subjects across four paradigms: OVAR, VRC, sled translation and rotation about an earth-horizontal axis. Subjects were oscillated in darkness at six frequencies from 0.01875 to 0.6 Hz (peak acceleration equivalent to 10 deg, less for sled motion below 0.15 Hz). Subjects verbally described the amplitude of perceived tilt and translation, and used a joystick to indicate the direction of motion. Consistent with previous reports, tilt perception gain decreased as a function of stimulus frequency in the motion paradigms without concordant canal tilt cues (OVAR, VRC and Sled). Translation perception gain was negligible at low stimulus frequencies and increased at higher frequencies. There were no significant differences between the phase of tilt and translation, nor did the phase significantly vary across stimulus frequency. There were differences in perception gain across the different paradigms. Paradigms that included actual tilt stimuli had the larger tilt gains, and paradigms that included actual translation stimuli had larger translation gains. In addition, the frequency at which there was a crossover of tilt and translation gains appeared to vary across motion paradigm between 0.15 and 0.3 Hz. Since the linear acceleration in the head lateral plane was equivalent across paradigms, differences in gain may be attributable to the presence of linear accelerations in orthogonal directions and/or cognitive aspects based on the expected motion paths.

  10. SU-E-T-543: Measurement of Neutron Activation From Different High Energy Varian Linear Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Thatcher, T; Madsen, S; Sudowe, R [University of Nevada, Las Vegas, Las Vegas, NV (United States); Meigooni, A Soleimani [University of Nevada, Las Vegas, Las Vegas, NV (United States); Comprehensive Cancer Center of Nevada, Las Vegas, Nevada (United States)

    2015-06-15

    Purpose: Linear accelerators producing photons above 10 MeV may induce photonuclear reactions in high Z components of the accelerator. These liberated neutrons can then activate the structural components of the accelerator and other materials in the beam path through neutron capture reactions. The induced activity within the accelerator may contribute to additional dose to both patients and personnel. This project seeks to determine the total activity and activity per activated isotope following irradiation in different Varian accelerators at energies above 10 MeV. Methods: A Varian 21IX accelerator was used to irradiate a 30 cm × 30 cm × 20 cm solid water phantom with 15 MV x-rays. The phantom was placed at an SSD of 100 cm and at the center of a 20 cm × 20 cm field. Activation induced gamma spectra were acquired over a 5 minute interval after 1 and 15 minutes from completion of the irradiation. All measurements were made using a CANBERRA Falcon 5000 Portable HPGe detector. The majority of measurements were made in scattering geometry with the detector situated at 90° to the incident beam, 30 cm from the side of the phantom and approximately 10 cm from the top. A 5 minute background count was acquired and automatically subtracted from all subsequent measurements. Photon spectra were acquired for both open and MLC fields. Results: Based on spectral signatures, nuclides have been identified and their activities calculated for both open and MLC fields. Preliminary analyses suggest that activities from the activation products in the microcurie range. Conclusion: Activation isotopes have been identified and their relative activities determined. These activities are only gross estimates since efficiencies have not been determined for this source-detector geometry. Current efforts are focused on accurate determination of detector efficiencies using Monte Carlo calculations.

  11. AMS of heavy elements with an ECR ion source and the ATLAS linear accelerator

    CERN Document Server

    Paul, M; Ahmad, I; Borasi, F; Caggiano, J; Davids, C N; Greene, J P; Harss, B; Heinz, A; Henderson, D J; Henning, W F; Jiang, C L; Pardo, R C; Rehm, K E; Rejoub, R; Seweryniak, D; Sonzogni, A; Uusitalo, J; Vondrasek, R C

    2000-01-01

    Detection of heavy elements by accelerator mass spectrometry with the electron cyclotron resonance ion source, Argonne linear accelerator and fragment mass analyzer (ECRIS-ATLAS-FMA) system has been developed. The use of the ECR-ATLAS system for AMS of heavy elements has two interesting features: (i) the efficient production of high-charge state ions in the ECR source ensures the elimination of molecular ions at the source stage, a highly attractive feature for any mass-spectrometric use not exploited so far; (ii) the linear acceleration based on velocity matching and the beam transport system act as a powerful mass filter for background suppression. We have shown that our system reaches an abundance sensitivity of 1x10 sup - sup 1 sup 4 for Pb isotopes. The sup 2 sup 3 sup 6 U detection sensitivity is sup 2 sup 3 sup 6 U/U > or approx. 1x10 sup - sup 1 sup 2 , limited mainly by the ion source output.

  12. The International Linear Collider Technical Design Report - Volume 3.II: Accelerator Baseline Design

    CERN Document Server

    Adolphsen, Chris; Barish, Barry; Buesser, Karsten; Burrows, Philip; Carwardine, John; Clark, Jeffrey; Durand, Helene Mainaud; Dugan, Gerry; Elsen, Eckhard; Enomoto, Atsushi; Foster, Brian; Fukuda, Shigeki; Gai, Wei; Gastal, Martin; Geng, Rongli; Ginsburg, Camille; Guiducci, Susanna; Harrison, Mike; Hayano, Hitoshi; Kershaw, Keith; Kubo, Kiyoshi; Kuchler, Victor; List, Benno; Liu, Wanming; Michizono, Shinichiro; Nantista, Christopher; Osborne, John; Palmer, Mark; Paterson, James McEwan; Peterson, Thomas; Phinney, Nan; Pierini, Paolo; Ross, Marc; Rubin, David; Seryi, Andrei; Sheppard, John; Solyak, Nikolay; Stapnes, Steinar; Tauchi, Toshiaki; Toge, Nobu; Walker, Nicholas; Yamamoto, Akira; Yokoya, Kaoru

    2013-01-01

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to incr...

  13. The generation and acceleration of low emittance flat beams for future linear colliders

    Energy Technology Data Exchange (ETDEWEB)

    Raubenheimer, T.O.

    1991-11-01

    Many future linear collider designs call for electron and positron beams with normalized rms horizontal and vertical emittances of {gamma}{epsilon}{sub x} = 3{times}10{sup {minus}6} m-rad and {gamma}{epsilon}{sub y} = 3{times}10{sup {minus}8} m-rad; these are a factor of 10 to 100 below those observed in the Stanford Linear Collider. In this dissertation, we examine the feasibility of achieving beams with these very small vertical emittances. We examine the limitations encountered during both the generation and the subsequent acceleration of such low emittance beams. We consider collective limitations, such as wakefields, space charge effects, scattering processes, and ion trapping; and also how intensity limitations, such as anomalous dispersion, betatron coupling, and pulse-to-pulse beam jitter. In general, the minimum emittance in both the generation and the acceleration stages is limited by the transverse misalignments of the accelerator components. We describe a few techniques of correcting the effect of these errors, thereby easing the alignment tolerances by over an order of magnitude. Finally, we also calculate ``fundamental`` limitations on the minimum vertical emittance; these do not constrain the current designs but may prove important in the future.

  14. The generation and acceleration of low emittance flat beams for future linear colliders

    Energy Technology Data Exchange (ETDEWEB)

    Raubenheimer, T.O.

    1991-11-01

    Many future linear collider designs call for electron and positron beams with normalized rms horizontal and vertical emittances of {gamma}{epsilon}{sub x} = 3{times}10{sup {minus}6} m-rad and {gamma}{epsilon}{sub y} = 3{times}10{sup {minus}8} m-rad; these are a factor of 10 to 100 below those observed in the Stanford Linear Collider. In this dissertation, we examine the feasibility of achieving beams with these very small vertical emittances. We examine the limitations encountered during both the generation and the subsequent acceleration of such low emittance beams. We consider collective limitations, such as wakefields, space charge effects, scattering processes, and ion trapping; and also how intensity limitations, such as anomalous dispersion, betatron coupling, and pulse-to-pulse beam jitter. In general, the minimum emittance in both the generation and the acceleration stages is limited by the transverse misalignments of the accelerator components. We describe a few techniques of correcting the effect of these errors, thereby easing the alignment tolerances by over an order of magnitude. Finally, we also calculate fundamental'' limitations on the minimum vertical emittance; these do not constrain the current designs but may prove important in the future.

  15. The International Linear Collider Technical Design Report - Volume 3.II: Accelerator Baseline Design

    Energy Technology Data Exchange (ETDEWEB)

    Adolphsen, Chris [SLAC National Accelerator Lab., Menlo Park, CA (United States); et al.

    2013-06-26

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.

  16. The International Linear Collider Technical Design Report - Volume 3.I: Accelerator \\& in the Technical Design Phase

    Energy Technology Data Exchange (ETDEWEB)

    Adolphsen, Chris [SLAC National Accelerator Lab., Menlo Park, CA (United States); et al.

    2013-06-26

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.

  17. Evaluation of source term induced by beam loss in the superconducting linear accelerator at RAON

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Jin; Kim, Su Na; Nam, Shin Woo; Chung, Yon Sei [Rare Isotope Science Project, Institute for Basic Science, Daejeon (Korea, Republic of)

    2014-11-15

    As a new world-class heavy ion accelerator, RAON is able to accelerate heavy ions from proton to uranium with the energy up to -400 MeV/u and produce rare isotopes. These high purity, high intensity, and high energy beams generate the various secondary radiation which will impact on the shielding aspects of the main linear accelerator tunnels. In the main tunnel the secondary neutrons are produced by uniform beam-loss or accident criteria. In this paper evaluations of several source terms induced by beam-loss will be discussed along with the physics model of the Monte Carlo simulation codes. The beam-loss criteria were tested for the evaluation of source term for the main beam line tunnel of the RAON accelerator. It was found that the amount of the secondary neutrons depends on the incident angle of projectile on the beam pipe and the mass and energy of projectile. The influence of selected physics models and libraries of MCNPX and PHITS has been examined. The secondary neutrons were produced most in the CEM and LAQGSM model.

  18. TERA high gradient test program of RF cavities for medical linear accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Degiovanni, A., E-mail: alberto.degiovanni@cern.ch [TERA Foundation-via G. Puccini 11, 28100 Novara (Italy); Ecole Polytechnique Federale Lausanne EPFL-1015 Lausanne (Switzerland); Amaldi, U. [TERA Foundation-via G. Puccini 11, 28100 Novara (Italy); Universita Milano Bicocca-Piazza della Scienza 1, 20126 Milan (Italy); Bonomi, R. [TERA Foundation-via G. Puccini 11, 28100 Novara (Italy); Politecnico di Torino-Corso Duca degli Abruzzi 24, 10129 Turin (Italy); Garlasche, M. [TERA Foundation-via G. Puccini 11, 28100 Novara (Italy); Garonna, A. [TERA Foundation-via G. Puccini 11, 28100 Novara (Italy); Ecole Polytechnique Federale Lausanne EPFL-1015 Lausanne (Switzerland); Verdu-Andres, S. [TERA Foundation-via G. Puccini 11, 28100 Novara (Italy); Instituto de Fisica Corpuscular IFIC (CSIC-UVEG)-Paterna, 46071 Valencia (Spain); Wegner, R. [CERN- 1211 Geneva (Switzerland)

    2011-11-21

    The scientific community and the medical industries are putting a considerable effort into the design of compact, reliable and cheap accelerators for hadrontherapy. Up to now only circular accelerators are used to deliver beams with energies suitable for the treatment of deep seated tumors. The TERA Foundation has proposed and designed a hadrontherapy facility based on the cyclinac concept: a high gradient linear accelerator placed downstream of a cyclotron used as an injector. The overall length of the linac, and therefore its final cost, is almost inversely proportional to the average accelerating gradient achieved in the linac. TERA, in collaboration with the CLIC RF group, has started a high gradient test program. The main goal is to study the high gradient behavior of prototype cavities and to determine the appropriate linac operating frequency considering important issues such as machine reliability and availability of distributed power sources. A preliminary test of a 3 GHz cavity has been carried out at the beginning of 2010, giving encouraging results. Further investigations are planned before the end of 2011. A set of 5.7 GHz cavities is under production and will be tested in a near future. The construction and test of a multi-cell structure is also foreseen.

  19. TERA high gradient test program of RF cavities for medical linear accelerators

    Science.gov (United States)

    Degiovanni, A.; Amaldi, U.; Bonomi, R.; Garlasché, M.; Garonna, A.; Verdú-Andrés, S.; Wegner, R.

    2011-11-01

    The scientific community and the medical industries are putting a considerable effort into the design of compact, reliable and cheap accelerators for hadrontherapy. Up to now only circular accelerators are used to deliver beams with energies suitable for the treatment of deep seated tumors. The TERA Foundation has proposed and designed a hadrontherapy facility based on the cyclinac concept: a high gradient linear accelerator placed downstream of a cyclotron used as an injector. The overall length of the linac, and therefore its final cost, is almost inversely proportional to the average accelerating gradient achieved in the linac. TERA, in collaboration with the CLIC RF group, has started a high gradient test program. The main goal is to study the high gradient behavior of prototype cavities and to determine the appropriate linac operating frequency considering important issues such as machine reliability and availability of distributed power sources. A preliminary test of a 3 GHz cavity has been carried out at the beginning of 2010, giving encouraging results. Further investigations are planned before the end of 2011. A set of 5.7 GHz cavities is under production and will be tested in a near future. The construction and test of a multi-cell structure is also foreseen.

  20. GPU Linear Algebra Libraries and GPGPU Programming for Accelerating MOPAC Semiempirical Quantum Chemistry Calculations.

    Science.gov (United States)

    Maia, Julio Daniel Carvalho; Urquiza Carvalho, Gabriel Aires; Mangueira, Carlos Peixoto; Santana, Sidney Ramos; Cabral, Lucidio Anjos Formiga; Rocha, Gerd B

    2012-09-11

    In this study, we present some modifications in the semiempirical quantum chemistry MOPAC2009 code that accelerate single-point energy calculations (1SCF) of medium-size (up to 2500 atoms) molecular systems using GPU coprocessors and multithreaded shared-memory CPUs. Our modifications consisted of using a combination of highly optimized linear algebra libraries for both CPU (LAPACK and BLAS from Intel MKL) and GPU (MAGMA and CUBLAS) to hasten time-consuming parts of MOPAC such as the pseudodiagonalization, full diagonalization, and density matrix assembling. We have shown that it is possible to obtain large speedups just by using CPU serial linear algebra libraries in the MOPAC code. As a special case, we show a speedup of up to 14 times for a methanol simulation box containing 2400 atoms and 4800 basis functions, with even greater gains in performance when using multithreaded CPUs (2.1 times in relation to the single-threaded CPU code using linear algebra libraries) and GPUs (3.8 times). This degree of acceleration opens new perspectives for modeling larger structures which appear in inorganic chemistry (such as zeolites and MOFs), biochemistry (such as polysaccharides, small proteins, and DNA fragments), and materials science (such as nanotubes and fullerenes). In addition, we believe that this parallel (GPU-GPU) MOPAC code will make it feasible to use semiempirical methods in lengthy molecular simulations using both hybrid QM/MM and QM/QM potentials.

  1. Power System Design Compromises for Large-Scale Linear Particle Accelerators

    CERN Document Server

    Papastergiou, K D

    2014-01-01

    This paper discusses various design aspects of a 280MW Power System for the Compact Linear Collider (CLIC), a 50km long electrons-positrons accelerator, under feasibility evaluation. The key requirements are a very high accelerator availability and constant power flow from the utility grid, considering the pulsed power nature of CLIC. Firstly, the possible power network and cabling layouts are discussed along with potential difficulties on electrical fault clearance. Following, the use of active front-end converters is examined as a means to control the power flow and power quality seen by the 400kV grid. In particular a modular multilevel converter preliminary configuration is described and the compromises related to energy storage and voltage level are discussed.

  2. Parameter choices for a muon recirculating linear accelerator from 5 to 63 GeV

    Energy Technology Data Exchange (ETDEWEB)

    Berg, J. S. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2014-06-19

    A recirculating linear accelerator (RLA) has been proposed to accelerate muons from 5 to 63 GeV for a muon collider. It should be usable both for a Higgs factory and as a stage for a higher energy collider. First, the constraints due to the beam loading are computed. Next, an expression for the longitudinal emittance growth to lowest order in the longitudinal emittance is worked out. After finding the longitudinal expression, a simplified model that describes the arcs and their approximate expression for the time of flight dependence on energy in those arcs is found. Finally, these results are used to estimate the parameters required for the RLA arcs and the linac phase.

  3. Dosimetric aspects of the therapeutic photon beams from a dual-energy linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Al-Ghazi, M.S.A.L.; Arjune, B.; Fiedler, J.A.; Sharma, P.D.

    1988-03-01

    Parameters of the photon beams (6 and 20 MV) from a dual-energy linear accelerator (Mevatron-KD, Siemens Medical Laboratories, CA) are presented. The depth dose characteristics of the photon beams are d/sub max/ of 1.8 and 3.8 cm and percentage depth dose of 68% and 80% at 10-cm depth and 100-cm source--surface distance for a field size of 10 x 10 cm/sup 2/ for 6 and 20 MV, respectively. The 6 and 20 MV beams were found to correspond to nominal accelerating potentials of 4.7 and 17 MV, respectively. The stability of output is within +- 1% and flatness and symmetry are within +- 3%. These figures compare favorably with the manufacturer's specifications.

  4. A review of vector convergence acceleration methods, with applications to linear algebra problems

    Science.gov (United States)

    Brezinski, C.; Redivo-Zaglia, M.

    In this article, in a few pages, we will try to give an idea of convergence acceleration methods and extrapolation procedures for vector sequences, and to present some applications to linear algebra problems and to the treatment of the Gibbs phenomenon for Fourier series in order to show their effectiveness. The interested reader is referred to the literature for more details. In the bibliography, due to space limitation, we will only give the more recent items, and, for older ones, we refer to Brezinski and Redivo-Zaglia, Extrapolation methods. (Extrapolation Methods. Theory and Practice, North-Holland, 1991). This book also contains, on a magnetic support, a library (in Fortran 77 language) for convergence acceleration algorithms and extrapolation methods.

  5. Visual Outcome in Meningiomas Around Anterior Visual Pathways Treated With Linear Accelerator Fractionated Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Stiebel-Kalish, Hadas, E-mail: kalishhadas@gmail.com [Neuro-Ophthalmology Unit, Rabin Medical Center, Petah Tikva (Israel); Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Reich, Ehud [Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Department of Ophthalmology, Rabin Medical Center, Petah Tikva (Israel); Gal, Lior [Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Rappaport, Zvi Harry [Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Department of Neurosurgery, Rabin Medical Center, Petah Tikva (Israel); Nissim, Ouzi [Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Stereotactic Radiosurgery Unit, Sheba Medical Center, Ramat Gan (Israel); Department of Neurosurgery, Sheba Medical Center, Ramat Gan (Israel); Pfeffer, Raphael [Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Stereotactic Radiosurgery Unit, Sheba Medical Center, Ramat Gan (Israel); Spiegelmann, Roberto [Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Stereotactic Radiosurgery Unit, Sheba Medical Center, Ramat Gan (Israel); Department of Neurosurgery, Sheba Medical Center, Ramat Gan (Israel)

    2012-02-01

    Purpose: Meningiomas threatening the anterior visual pathways (AVPs) and not amenable for surgery are currently treated with multisession stereotactic radiotherapy. Stereotactic radiotherapy is available with a number of devices. The most ubiquitous include the gamma knife, CyberKnife, tomotherapy, and isocentric linear accelerator systems. The purpose of our study was to describe a case series of AVP meningiomas treated with linear accelerator fractionated stereotactic radiotherapy (FSRT) using the multiple, noncoplanar, dynamic conformal rotation paradigm and to compare the success and complication rates with those reported for other techniques. Patients and Methods: We included all patients with AVP meningiomas followed up at our neuro-ophthalmology unit for a minimum of 12 months after FSRT. We compared the details of the neuro-ophthalmologic examinations and tumor size before and after FSRT and at the end of follow-up. Results: Of 87 patients with AVP meningiomas, 17 had been referred for FSRT. Of the 17 patients, 16 completed >12 months of follow-up (mean 39). Of the 16 patients, 11 had undergone surgery before FSRT and 5 had undergone FSRT as first-line management. Tumor control was achieved in 14 of the 16 patients, with three meningiomas shrinking in size after RT. Two meningiomas progressed, one in an area that was outside the radiation field. The visual function had improved in 6 or stabilized in 8 of the 16 patients (88%) and worsened in 2 (12%). Conclusions: Linear accelerator fractionated RT using the multiple noncoplanar dynamic rotation conformal paradigm can be offered to patients with meningiomas that threaten the anterior visual pathways as an adjunct to surgery or as first-line treatment, with results comparable to those reported for other stereotactic RT techniques.

  6. Commissioning and early experience with a new-generation low-energy linear accelerator with advanced delivery and imaging functionalities

    Directory of Open Access Journals (Sweden)

    Fogliata Antonella

    2011-09-01

    Full Text Available Abstract Background A new-generation low-energy linear accelerator (UNIQUE was introduced in the clinical arena during 2009 by Varian Medical Systems. The world's first UNIQUE was installed at Oncology Institute of Southern Switzerland and put into clinical operation in June 2010. The aim of the present contribution was to report experience about its commissioning and first year results from clinical operation. Methods Commissioning data, beam characteristics and the modeling into the treatment planning system were summarized. Imaging system of UNIQUE included a 2D-2D matching capability and tests were performed to identify system repositioning capability. Finally, since the system is capable of delivering volumetric modulated arc therapy with RapidArc, a summary of the tests performed for such modality to assess its performance in preclinical settings and during clinical usage was included. Results Isocenter virtual diameter was measured as less than 0.2 mm. Observed accuracy of isocenter determination and repositioning for 2D-2D matching procedures in image guidance was Conclusions The results of the commissioning tests and of the first period of clinical operation, resulted meeting specifications and having good margins respect to tolerances. UNIQUE was put into operation for all delivery techniques; in particular, as shown by the pre-treatment quality assurance results, it enabled accurate and safe delivery of RapidArc plans.

  7. Contemporary methods of radiosurgery treatment with the Novalis linear accelerator system.

    Science.gov (United States)

    Chen, Joseph C T; Rahimian, Javad; Girvigian, Michael R; Miller, Michael J

    2007-01-01

    Radiosurgery has emerged as an indispensable component of the multidisciplinary approach to neoplastic, functional, and vascular diseases of the central nervous system. In recent years, a number of newly developed integrated systems have been introduced for radiosurgery and fractionated stereotactic radiotherapy treatments. These modern systems extend the flexibility of radiosurgical treatment in allowing the use of frameless image-guided radiation delivery as well as high-precision fractionated treatments. The Novalis linear accelerator system demonstrates adequate precision and reliability for cranial and extracranial radiosurgery, including functional treatments utilizing either frame-based or frameless image-guided methods.

  8. Measurements of Neutron Induced Cross Sections at the Oak Ridge Electron Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Guber, K.H.; Harvey, J.A.; Hill, N.W.; Koehler, P.E.; Leal, L.C.; Sayer, R.O.; Spencer, R.R.

    1999-09-20

    We have used the Oak Ridge Electron Linear Accelerator (ORELA) to measure neutron total and the fission cross sections of 233U in the energy range from 0.36 eV to ~700 keV. We report average fission and total cross sections. Also, we measured the neutron total cross sections of 27Al and Natural chlorine as well as the capture cross section of Al over an energy range from 100 eV up to about 400 keV.

  9. Successful Application of Neutron Bubble Detectors in Neutron Dose Monitoring for Primus-M Election Linear Accelerators

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>Neutrons produced by 10 MeV medical electronic linear accelerators used for radiotherapy treatments may be harmful for medical personnel and patients. These neutrons are generated by the photon-induced

  10. Linear vs. nonlinear acceleration in plasma turbulence. I. Global versus local measures

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Sanjoy [Johns Hopkins University Applied Physics Laboratory, Laurel, Maryland 20723 (United States); Parashar, Tulasi N. [University of Delaware, Newark, Delaware 19716 (United States)

    2015-04-15

    Magnetized turbulent plasmas are generally characterized as strongly or weakly turbulent based on the average relative strengths of the linear and nonlinear terms. While this description is useful, it does not represent the full picture and can be misleading. We study the variation of linear and nonlinear accelerations in the Fourier space of a magnetohydrodynamic system with a mean magnetic field and broad selection of initial states and plasma parameters. We show that the local picture can show significant departures from what is expected from the general global picture. We find that high cross helicity systems that are traditionally believed to have relatively weaker nonlinearities, compared to low cross helicity systems, can show strong nonlinearities in parts of the Fourier space that are orthogonal to the mean magnetic field direction. In some cases, these nonlinearities can exceed in strength the level of nonlinearities recovered from low cross helicity systems.

  11. Measurements of the relative backscatter contribution to the monitor chamber for modern medical linear accelerators; A multi-center study

    DEFF Research Database (Denmark)

    Sibolt, Patrik; Cronholm, Rickard O.; Beierholm, Anders Ravnsborg

    2015-01-01

    Conversion to absolute dose in Monte Carlo (MC) simulations of MV radiotherapy beams needs correct modeling of backscatter (BS) to the linear accelerator (linac) monitor chamber. For some linacs the BS depends largely on jaw settings. The backscattered fraction (BSF) of radiation can be determined...... experimentally by measuring ratios of target charge for a given number of monitor units as a function of jaw settings. This was done using the in-house developed ME40 dosimetry system, which is able to determine the target charge for each radiation pulse from the linac. The BSF measurements were performed...... for different linac models at five Danish radiotherapy clinics. The investigated linacs were four Varian TrueBeams (TB), one Varian iX (iX) and one Elekta Synergy (ES). BSF measurements were performed for square field side lengths ranging from 1 to 40 cm, using the 10 × 10 cm2 field as reference. The impact...

  12. Consequences of bounds on longitudinal emittance growth for the design of recirculating linear accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Berg, J. S. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2015-05-03

    Recirculating linear accelerators (RLAs) are a cost-effective method for the acceleration of muons for a muon collider in energy ranges from a couple GeV to a few 10s of GeV. Muon beams generally have longitudinal emittances that are large for the RF frequency that is used, and it is important to limit the growth of that longitudinal emittance. This has particular consequences for the arc design of the RLAs. I estimate the longitudinal emittance growth in an RLA arising from the RF nonlinearity. Given an emittance growth limitation and other design parameters, one can then compute the maximum momentum compaction in the arcs. I describe how to obtain an approximate arc design satisfying these requirements based on the deisgn in [1]. Longitudinal dynamics also determine the energy spread in the beam, and this has consequences on the transverse phase advance in the linac. This in turn has consequences for the arc design due to the need to match beta functions. I combine these considerations to discuss design parameters for the acceleration of muons for a collider in an RLA from 5 to 63 GeV.

  13. A dose-response curve for biodosimetry from a 6 MV electron linear accelerator.

    Science.gov (United States)

    Lemos-Pinto, M M P; Cadena, M; Santos, N; Fernandes, T S; Borges, E; Amaral, A

    2015-10-01

    Biological dosimetry (biodosimetry) is based on the investigation of radiation-induced biological effects (biomarkers), mainly dicentric chromosomes, in order to correlate them with radiation dose. To interpret the dicentric score in terms of absorbed dose, a calibration curve is needed. Each curve should be constructed with respect to basic physical parameters, such as the type of ionizing radiation characterized by low or high linear energy transfer (LET) and dose rate. This study was designed to obtain dose calibration curves by scoring of dicentric chromosomes in peripheral blood lymphocytes irradiated in vitro with a 6 MV electron linear accelerator (Mevatron M, Siemens, USA). Two software programs, CABAS (Chromosomal Aberration Calculation Software) and Dose Estimate, were used to generate the curve. The two software programs are discussed; the results obtained were compared with each other and with other published low LET radiation curves. Both software programs resulted in identical linear and quadratic terms for the curve presented here, which was in good agreement with published curves for similar radiation quality and dose rates.

  14. A dose-response curve for biodosimetry from a 6 MV electron linear accelerator

    Directory of Open Access Journals (Sweden)

    M.M.P. Lemos-Pinto

    2015-01-01

    Full Text Available Biological dosimetry (biodosimetry is based on the investigation of radiation-induced biological effects (biomarkers, mainly dicentric chromosomes, in order to correlate them with radiation dose. To interpret the dicentric score in terms of absorbed dose, a calibration curve is needed. Each curve should be constructed with respect to basic physical parameters, such as the type of ionizing radiation characterized by low or high linear energy transfer (LET and dose rate. This study was designed to obtain dose calibration curves by scoring of dicentric chromosomes in peripheral blood lymphocytes irradiated in vitro with a 6 MV electron linear accelerator (Mevatron M, Siemens, USA. Two software programs, CABAS (Chromosomal Aberration Calculation Software and Dose Estimate, were used to generate the curve. The two software programs are discussed; the results obtained were compared with each other and with other published low LET radiation curves. Both software programs resulted in identical linear and quadratic terms for the curve presented here, which was in good agreement with published curves for similar radiation quality and dose rates.

  15. A dose-response curve for biodosimetry from a 6 MV electron linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lemos-Pinto, M.M.P.; Cadena, M.; Santos, N.; Fernandes, T.S.; Borges, E.; Amaral, A., E-mail: marcelazoo@yahoo.com.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear

    2015-10-15

    Biological dosimetry (biodosimetry) is based on the investigation of radiation-induced biological effects (biomarkers), mainly dicentric chromosomes, in order to correlate them with radiation dose. To interpret the dicentric score in terms of absorbed dose, a calibration curve is needed. Each curve should be constructed with respect to basic physical parameters, such as the type of ionizing radiation characterized by low or high linear energy transfer (LET) and dose rate. This study was designed to obtain dose calibration curves by scoring of dicentric chromosomes in peripheral blood lymphocytes irradiated in vitro with a 6 MV electron linear accelerator (Mevatron M, Siemens, USA). Two software programs, CABAS (Chromosomal Aberration Calculation Software) and Dose Estimate, were used to generate the curve. The two software programs are discussed; the results obtained were compared with each other and with other published low LET radiation curves. Both software programs resulted in identical linear and quadratic terms for the curve presented here, which was in good agreement with published curves for similar radiation quality and dose rates. (author)

  16. Why most traumatic brain injuries are not caused by linear acceleration but skull fractures are.

    Directory of Open Access Journals (Sweden)

    Svein eKleiven

    2013-11-01

    Full Text Available Injury statistics have found the most common accident situation to be an oblique impact. An oblique impact will give rise to both linear and rotational head kinematics. The human brain is most sensitive to rotational motion. The bulk modulus of brain tissue is roughly five to six orders of magnitude larger than the shear modulus so that for a given impact it tends to deform predominantly in shear. This gives a large sensitivity of the strain in the brain to rotational loading and a small sensitivity to linear kinematics. Therefore, rotational kinematics should be a better indicator of traumatic brain injury risk than linear acceleration. To illustrate the difference between radial and oblique impacts, perpendicular impacts through the center of gravity of the head and 45o oblique impacts were simulated. It is obvious that substantially higher strain levels in the brain are obtained for an oblique impact, compared to a corresponding perpendicular one, when impacted into the same padding using an identical impact velocity. It was also clearly illustrated that the radial impact causes substantially higher stresses in the skull with an associated higher risk of skull fractures, and traumatic brain injuries secondary to those.

  17. A dose-response curve for biodosimetry from a 6 MV electron linear accelerator

    Science.gov (United States)

    Lemos-Pinto, M.M.P.; Cadena, M.; Santos, N.; Fernandes, T.S.; Borges, E.; Amaral, A.

    2015-01-01

    Biological dosimetry (biodosimetry) is based on the investigation of radiation-induced biological effects (biomarkers), mainly dicentric chromosomes, in order to correlate them with radiation dose. To interpret the dicentric score in terms of absorbed dose, a calibration curve is needed. Each curve should be constructed with respect to basic physical parameters, such as the type of ionizing radiation characterized by low or high linear energy transfer (LET) and dose rate. This study was designed to obtain dose calibration curves by scoring of dicentric chromosomes in peripheral blood lymphocytes irradiated in vitro with a 6 MV electron linear accelerator (Mevatron M, Siemens, USA). Two software programs, CABAS (Chromosomal Aberration Calculation Software) and Dose Estimate, were used to generate the curve. The two software programs are discussed; the results obtained were compared with each other and with other published low LET radiation curves. Both software programs resulted in identical linear and quadratic terms for the curve presented here, which was in good agreement with published curves for similar radiation quality and dose rates. PMID:26445334

  18. Medium-Term Stability of the Photon Beam Energy of An Elekta CompactTM Linear Accelerator Based on Daily Measurements of Beam Quality Factor

    Directory of Open Access Journals (Sweden)

    Mohammad Amin Mosleh-Shirazi

    2016-04-01

    Full Text Available Introduction In this study, we aimed to assess the medium-term energy stability of a 6MV Elekta CompactTM linear accelerator. To the best of our knowledge, this is the first published article to evaluate this linear accelerator in terms of energy stability. As well as investigating the stability of the linear accelerator energy over a period of several weeks, the results will be useful for estimation of the required tolerance values for the beam quality factor (BQF of the PTW QUICKCHECK weblineTM (QCW daily checking device. Materials and Methods Over a 13 week period of routine clinical service, 52 daily readings of BQF were taken and then analyzed for a 10×10 cm2 field. Results No decreasing or increasing trend in BQF was observed over the study period. The mean BQF value was estimated at 5.4483 with a standard deviation (SD of 0.0459 (0.8%. The mean value was only 0.1% different from the baseline value. Conclusion The results of this medium-term stability study of the Elekta Compact linear accelerator energy showed that 96.2% of the observed BQF values were within ±1.3% of the baseline value. This can be considered to be within the recommended tolerance for linear accelerator photon beam energy. If an approach of applying ±3 SD is taken, the tolerance level for BQF may be suggested to be set at ±2.5%. However, further research is required to establish a relationship between BQF value and the actual changes in beam energy and penetrative quality.

  19. Experimental investigations of the neutron contamination in high-energy photon fields at medical linear accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Brunckhorst, Elin

    2009-02-26

    The scope of this thesis was to develop a device for the detection of the photoneutron dose inside the high-energy photon field. The photoneutron contamination of a Siemens PRIMUS linear accelerator was investigated in detail in its 15 MV photon mode. The experimental examinations were performed with three ionisation chambers (a tissue equivalent chamber, a magnesium chamber and a {sup 10}B-coated magnesium chamber) and two types of thermoluminescence detectors (enriched with {sup 6}Li and {sup 7}Li, respectively). The detectors have different sensitivities to photons and neutrons and their combination allows the dose separation in a mixed neutron/photon field. The application of the ionisation chamber system, as well as the present TLD system for photoneutron detection in high-energy photon beams is a new approach. The TLD neutron sensitivity was found to be too low for a measurement inside the open photon field and the further investigation focused on the ionisation chambers. The three ionisation chambers were calibrated at different photon and neutron sources and a the borated magnesium chamber showed a very high response to thermal neutrons. For a cross check of the calibration, the three chambers were also used for dose separation of a boron neutron capture therapy beam where the exact determination of the thermal neutron dose is essential. Very accurate results were achieved for the thermal neutron dose component. At the linear accelerator the chamber system was reduced to a paired chamber system utilising the two magnesium chambers, since the fast neutron component was to small to be separated. The neutron calibration of the three chambers could not be applied, instead a conversion of measured thermal neutron signal by the borated chamber to Monte Carlo simulated total neutron dose was performed. Measurements for open fields in solid water and liquid water were performed with the paired chamber system. In larger depths the neutron dose could be determined

  20. One Year assessment of shielding for a multi-energy linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Gi; Carlson, Joel; Lee, Hyun Seok; Ye, Sung Joon [Seoul National University Graduate School of Convergence Science and Technology, Seoul (Korea, Republic of); Chung, Jin Beom; Kim, Jae Sung [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Seoul (Korea, Republic of); Kim, Jung In [Dept. of of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2014-11-15

    In 2005, the publication of Report No. 151 of the National Council on Radiation Protection and Measurements (NCRP) suggested shielding methodologies along with shielding data. Recently, intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) have become more widely used for cancer treatment. Thus, we analyzed shielding parameters for a multi-energy medical linear accelerator using the VMAT technique. Calculated total workload was similar to the recommendation of NCRP Report No. 49 and No. 51. However, these results were higher than the previous results in the NCRP Report No. 151. Also, the VMAT technique uses an intensity modulated beams with various gantry angles so that scattered and leakage doses should be carefully considered by retrospective analysis using the treatment data from each facility.

  1. Performance of Superconducting Magnet Prototypes for LCLS-II Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kashikhin, Vladimir [Fermilab; Andreev, Nikolai [Fermilab; DiMarco, Joseph [Fermilab; Makarov, Alexander [Fermilab; Tartaglia, Michael [Fermilab; Velev, George [Fermilab

    2016-12-30

    The new LCLS-II Linear Superconducting Accelerator at SLAC needs superconducting magnet packages installed inside SCRF Cryomodules to focus and steer an electron beam. Two magnet prototypes were built and successfully tested at Fermilab. Magnets have an iron dominated configuration, quadrupole and dipole NbTi superconducting coils, and splittable in the vertical plane configuration. Magnets inside the Cryomodule are conductively cooled through pure Al heat sinks. Both magnets performance was verified by magnetic measurements at room temperature, and during cold tests in liquid helium. Test results including magnetic measurements are discussed. Special attention was given to the magnet performance at low currents where the iron yoke and the superconductor hysteresis effects have large influence. Both magnet prototypes were accepted for the installation in FNAL and JLAB prototype Cryomodules.

  2. High energy X-ray photon counting imaging using linear accelerator and silicon strip detectors

    Science.gov (United States)

    Tian, Y.; Shimazoe, K.; Yan, X.; Ueda, O.; Ishikura, T.; Fujiwara, T.; Uesaka, M.; Ohno, M.; Tomita, H.; Yoshihara, Y.; Takahashi, H.

    2016-09-01

    A photon counting imaging detector system for high energy X-rays is developed for on-site non-destructive testing of thick objects. One-dimensional silicon strip (1 mm pitch) detectors are stacked to form a two-dimensional edge-on module. Each detector is connected to a 48-channel application specific integrated circuit (ASIC). The threshold-triggered events are recorded by a field programmable gate array based counter in each channel. The detector prototype is tested using 950 kV linear accelerator X-rays. The fast CR shaper (300 ns pulse width) of the ASIC makes it possible to deal with the high instant count rate during the 2 μs beam pulse. The preliminary imaging results of several metal and concrete samples are demonstrated.

  3. High energy X-ray photon counting imaging using linear accelerator and silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Y., E-mail: cycjty@sophie.q.t.u-tokyo.ac.jp [Department of Bioengineering, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Shimazoe, K.; Yan, X. [Department of Nuclear Engineering and Management, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Ueda, O.; Ishikura, T. [Fuji Electric Co., Ltd., Fuji, Hino, Tokyo 191-8502 (Japan); Fujiwara, T. [National Institute of Advanced Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Uesaka, M.; Ohno, M. [Nuclear Professional School, the University of Tokyo, 2-22 Shirakata-shirane, Tokai, Ibaraki 319-1188 (Japan); Tomita, H. [Department of Quantum Engineering, Nagoya University, Furo, Chikusa, Nagoya 464-8603 (Japan); Yoshihara, Y. [Department of Nuclear Engineering and Management, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Takahashi, H. [Department of Bioengineering, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Department of Nuclear Engineering and Management, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2016-09-11

    A photon counting imaging detector system for high energy X-rays is developed for on-site non-destructive testing of thick objects. One-dimensional silicon strip (1 mm pitch) detectors are stacked to form a two-dimensional edge-on module. Each detector is connected to a 48-channel application specific integrated circuit (ASIC). The threshold-triggered events are recorded by a field programmable gate array based counter in each channel. The detector prototype is tested using 950 kV linear accelerator X-rays. The fast CR shaper (300 ns pulse width) of the ASIC makes it possible to deal with the high instant count rate during the 2 μs beam pulse. The preliminary imaging results of several metal and concrete samples are demonstrated.

  4. Test Results of a Superconducting Quadrupole Model Designed for Linear Accelerator Applications

    Energy Technology Data Exchange (ETDEWEB)

    Kashikhin, Vladimir S.; Andreev, Nikolai; Chlachidze, Guram; DiMarco, Joseph; Kashikhin, Vadim V.; Lamm, Michael J.; Lopes, Mauricio L.; Orris, Darryl; Tartaglia, Michael; Tompkins, John C.; Velev, Gueorgui; /Fermilab

    2008-08-01

    The first model of a superconducting quadrupole for use in a Linear Accelerator was designed, built and tested at Fermilab. The quadrupole has a 78 mm aperture, and a cold mass length of 680 mm. A superferric magnet configuration with iron poles and four racetrack coils was chosen based on magnet performance, cost, and reliability considerations. Each coil is wound using enamel insulated, 0.5 mm diameter, NbTi superconductor. The quadrupole package also includes racetrack type dipole steering coils. The results of the quadrupole design, manufacturing and test, are presented. Specific issues related to the quadrupole magnetic center stability, superconductor magnetization and mechanical stability are discussed. The magnet quench performance and results of magnetic measurements will also be briefly discussed.

  5. An Electron Bunch Compression Scheme for a Superconducting Radio Frequency Linear Accelerator Driven Light Source

    Energy Technology Data Exchange (ETDEWEB)

    C. Tennant, S.V. Benson, D. Douglas, P. Evtushenko, R.A. Legg

    2011-09-01

    We describe an electron bunch compression scheme suitable for use in a light source driven by a superconducting radio frequency (SRF) linac. The key feature is the use of a recirculating linac to perform the initial bunch compression. Phasing of the second pass beam through the linac is chosen to de-chirp the electron bunch prior to acceleration to the final energy in an SRF linac ('afterburner'). The final bunch compression is then done at maximum energy. This scheme has the potential to circumvent some of the most technically challenging aspects of current longitudinal matches; namely transporting a fully compressed, high peak current electron bunch through an extended SRF environment, the need for a RF harmonic linearizer and the need for a laser heater. Additional benefits include a substantial savings in capital and operational costs by efficiently using the available SRF gradient.

  6. Highly-accelerated quantitative 2D and 3D localized spectroscopy with linear algebraic modeling (SLAM) and sensitivity encoding

    Science.gov (United States)

    Zhang, Yi; Gabr, Refaat E.; Zhou, Jinyuan; Weiss, Robert G.; Bottomley, Paul A.

    2013-12-01

    Noninvasive magnetic resonance spectroscopy (MRS) with chemical shift imaging (CSI) provides valuable metabolic information for research and clinical studies, but is often limited by long scan times. Recently, spectroscopy with linear algebraic modeling (SLAM) was shown to provide compartment-averaged spectra resolved in one spatial dimension with many-fold reductions in scan-time. This was achieved using a small subset of the CSI phase-encoding steps from central image k-space that maximized the signal-to-noise ratio. Here, SLAM is extended to two- and three-dimensions (2D, 3D). In addition, SLAM is combined with sensitivity-encoded (SENSE) parallel imaging techniques, enabling the replacement of even more CSI phase-encoding steps to further accelerate scan-speed. A modified SLAM reconstruction algorithm is introduced that significantly reduces the effects of signal nonuniformity within compartments. Finally, main-field inhomogeneity corrections are provided, analogous to CSI. These methods are all tested on brain proton MRS data from a total of 24 patients with brain tumors, and in a human cardiac phosphorus 3D SLAM study at 3T. Acceleration factors of up to 120-fold versus CSI are demonstrated, including speed-up factors of 5-fold relative to already-accelerated SENSE CSI. Brain metabolites are quantified in SLAM and SENSE SLAM spectra and found to be indistinguishable from CSI measures from the same compartments. The modified reconstruction algorithm demonstrated immunity to maladjusted segmentation and errors from signal heterogeneity in brain data. In conclusion, SLAM demonstrates the potential to supplant CSI in studies requiring compartment-average spectra or large volume coverage, by dramatically reducing scan-time while providing essentially the same quantitative results.

  7. Monte Carlo Simulation of Siemens ONCOR Linear Accelerator with BEAMnrc and DOSXYZnrc Code.

    Science.gov (United States)

    Jabbari, Keyvan; Anvar, Hossein Saberi; Tavakoli, Mohammad Bagher; Amouheidari, Alireza

    2013-07-01

    The Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. In this work, a Monte Carlo modeling of the Siemens ONCOR linear accelerator in 6 MV and 18 MV beams was performed. The results of simulation were validated by measurements in water by ionization chamber and extended dose range (EDR2) film in solid water. The linac's X-ray particular are so sensitive to the properties of primary electron beam. Square field size of 10 cm × 10 cm produced by the jaws was compared with ionization chamber and film measurements. Head simulation was performed with BEAMnrc and dose calculation with DOSXYZnrc for film measurements and 3ddose file produced by DOSXYZnrc analyzed used homemade MATLAB program. At 6 MV, the agreement between dose calculated by Monte Carlo modeling and direct measurement was obtained to the least restrictive of 1%, even in the build-up region. At 18 MV, the agreement was obtained 1%, except for in the build-up region. In the build-up region, the difference was 1% at 6 MV and 2% at 18 MV. The mean difference between measurements and Monte Carlo simulation is very small in both of ONCOR X-ray energy. The results are highly accurate and can be used for many applications such as patient dose calculation in treatment planning and in studies that model this linac with small field size like intensity-modulated radiation therapy technique.

  8. Characterestics of pico-second single bunch at the S-band linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Uesaka, Mitsuru (Nuclear Engineering Research Laboratory, University of Tokyo, 2-22 Shirakata-Shirane, Tokai-mura, Naka-gun, Ibaraki 319-11 (Japan)); Kozawa, Takahiro (Nuclear Engineering Research Laboratory, University of Tokyo, 2-22 Shirakata-Shirane, Tokai-mura, Naka-gun, Ibaraki 319-11 (Japan)); Kobayashi, Toshiaki (Nuclear Engineering Research Laboratory, University of Tokyo, 2-22 Shirakata-Shirane, Tokai-mura, Naka-gun, Ibaraki 319-11 (Japan)); Ueda, Toru (Nuclear Engineering Research Laboratory, University of Tokyo, 2-22 Shirakata-Shirane, Tokai-mura, Naka-gun, Ibaraki 319-11 (Japan)); Miya, Kenzo (Nuclear Engineering Research Laboratory, University of Tokyo, 2-22 Shirakata-Shirane, Tokai-mura, Naka-gun, Ibaraki 319-11 (Japan))

    1994-06-15

    Measurement of the bunch structure of a pico-second single bunch was performed using a femto-second streak camera at the S-band linear accelerator of the University of Tokyo. The aim of this research is to investigate the feasibility of the generation of a femto-second single bunch at the S-band linac. The details of the bunch structure and energy spectrum of an original single bunch were precisely investigated in several operation modes where the RF phases in accelerating tubes and a prebuncher were varied. The femto-second streak camera was utilized to measure the bunch structure by one shot via Cherenkov radiation emitted by the electrons in the bunch. Next, an experiment for magnetic pulse compression of the original single bunch was carried out. Pulse shapes of the compressed bunchs for different energy modulation were also obtained by measuring Cherenkov radiation by one shot using the femto-second streak camera. Prior to the experiment, numerical tracking analysis to determine operating parameters for the magnetic pulse compression was also done. Measured pulse widths were compared with calculated ones. Finally, a 2 ps (full width at half maximum; FWHM) single bunch with an electric charge of 0.3 nC could be generated by the magnetic pulse compression. ((orig.))

  9. Neutron research and facility development at the Oak Ridge Electron Linear Accelerator 1970 to 1995

    Energy Technology Data Exchange (ETDEWEB)

    Peelle, R.W.; Harvey, J.A.; Maienschein, F.C.; Weston, L.W.; Olsen, D.K.; Larson, D.C.; Macklin, R.L.

    1982-07-01

    This report reviews the accomplishments of the first decade of operation of the Oak Ridge Electron Linear Accelerator (ORELA) and discusses the plans for the facility in the coming decade. Motivations for scientific and applied research during the next decade are included. In addition, ORELA is compared with competing facilities, and prospects for ORELA's improvement and even replacement are reported. Development efforts for the next few years are outlined that are consistent with the anticipated research goals. Recommendations for hardware development include improving the electron injection system to give much larger short-pulse currents on a reliable basis, constructing an Electron Beam Injector Laboratory to help make this improvement possible, continuing a study of possibly replacing the electron accelerator with a proton machine, and replacing or upgrading the facility's data-acquistion and immediate-analysis computer systems. Increased operating time and more involvement of nuclear theorists are recommended, and an effective staff size for optimum use of this unique facility is discussed. A bibliography of all ORELA-related publications is included.

  10. The development of seismic guidelines for the Stanford Linear Accelerator Center

    Energy Technology Data Exchange (ETDEWEB)

    Huggins, R.

    1996-08-01

    This paper describes the development of Seismic Guidelines for the Stanford Linear Accelerator Center (SLAC). Although structures have always been built conservatively, SLAC management decided to review and update their seismic guidelines. SLAC is about mid-way between the epicenters of the 8.3 Richter magnitude 1906 San Francisco and the 7.2 Loma Prieta Earthquakes. The west end of the two mile long electron/positron particle accelerator lies a half mile from the large San Andreas Fault. Suggestions for seismic planning processes were solicited from local computer manufacturing firms, universities, and federal laboratories. A Committee of the various stakeholders in SLAC`s seismic planning retained an internationally known Seismic Planning Consultant and reviewed relevant standards and drafted Guidelines. A panel of seismic experts was convened to help define the hazard, site response spectra, probabilistic analysis of shaking, and near field effects. The Facility`s structures were assigned to seismic classes of importance, and an initial assessment of a sample of a dozen buildings conducted. This assessment resulted in emergency repairs to one structure, and provided a {open_quotes}reality basis{close_quotes} for establishing the final Guidelines and Administrative Procedures, and a program to evaluate remaining buildings, shielding walls, tunnels, and other special structures.

  11. Gamma-ray and neutron area monitoring system of linear IFMIF prototype accelerator building

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Hiroki, E-mail: takahashi.hiroki@jaea.go.jp [Japan Atomic Energy Agency (JAEA), Rokkasho, Aomori (Japan); Kojima, Toshiyuki; Narita, Takahiro; Tsutsumi, Kazuyoshi; Maebara, Sunao [Japan Atomic Energy Agency (JAEA), Rokkasho, Aomori (Japan); Sakaki, Hironao [JAEA, Kizugawa, Kyoto (Japan); Nishiyama, Koichi [IFMIF/EVEDA Project Team, Rokkasho, Aomori (Japan)

    2013-10-15

    Highlights: • Area monitoring system and control system are needed for LIPAc radiation management. • To secure the radiation safety, these systems are linked with two kinds of data path. • Hardwired data paths are adopted to realize the fast transfer of interlock signals. • Dual LAN and shared memory are adopted to the reliable transfer of monitoring data. • Data transfers without unnecessary load are designed and configured for these systems. -- Abstract: The linear IFMIF prototype accelerator (LIPAc) produces deuteron beam with 1 MW power. Since huge number of neutrons occur from such a high power beam, therefore, it is important for the radiation management to design a high reliability area monitoring system for gamma-rays and neutrons. To obtain the valuable operation data of the high-power deuteron beam at LIPAc, it is important to link and record the beam operation data and the area monitoring data. We realize the reliable data transfer to provide the area monitoring data to the accelerator control system which needs a high reliability using the shared-memory data link method. This paper describes the area monitoring system in the LIPAc building and the data-link between this system and the LIPAc control system.

  12. Microfluidic technologies for accelerating the clinical translation of nanoparticles

    Science.gov (United States)

    Valencia, Pedro M.; Farokhzad, Omid C.; Karnik, Rohit; Langer, Robert

    2012-10-01

    Using nanoparticles for therapy and imaging holds tremendous promise for the treatment of major diseases such as cancer. However, their translation into the clinic has been slow because it remains difficult to produce nanoparticles that are consistent 'batch-to-batch', and in sufficient quantities for clinical research. Moreover, platforms for rapid screening of nanoparticles are still lacking. Recent microfluidic technologies can tackle some of these issues, and offer a way to accelerate the clinical translation of nanoparticles. In this Progress Article, we highlight the advances in microfluidic systems that can synthesize libraries of nanoparticles in a well-controlled, reproducible and high-throughput manner. We also discuss the use of microfluidics for rapidly evaluating nanoparticles in vitro under microenvironments that mimic the in vivo conditions. Furthermore, we highlight some systems that can manipulate small organisms, which could be used for evaluating the in vivo toxicity of nanoparticles or for drug screening. We conclude with a critical assessment of the near- and long-term impact of microfluidics in the field of nanomedicine.

  13. Transverse beam dynamics in non-linear Fixed Field Alternating Gradient accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Haj, Tahar M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Meot, F. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-03-02

    In this paper, we present some aspects of the transverse beam dynamics in Fixed Field Ring Accelerators (FFRA): we start from the basic principles in order to derive the linearized transverse particle equations of motion for FFRA, essentially FFAGs and cyclotrons are considered here. This is a simple extension of a previous work valid for linear lattices that we generalized by including the bending terms to ensure its correctness for FFAG lattice. The space charge term (contribution of the internal coulombian forces of the beam) is contained as well, although it is not discussed here. The emphasis is on the scaling FFAG type: a collaboration work is undertaken in view of better understanding the properties of the 150 MeV scaling FFAG at KURRI in Japan, and progress towards high intensity operation. Some results of the benchmarking work between different codes are presented. Analysis of certain type of field imperfections revealed some interesting features about this machine that explain some of the experimental results and generalize the concept of a scaling FFAG to a non-scaling one for which the tune variations obey a well-defined law.

  14. Implementation of a linear mini accelerator for radiotherapy intraoperative; Puesta en marcha de un miniacelerador lineal para radioterapia intraoperatoria

    Energy Technology Data Exchange (ETDEWEB)

    Macias-Verde, D.; Yanez-Lopez, D.; Marti-Asenjo, J.; Sanchez-Carrascal, M.; Torres-Pozas, S.; Godoy-Cazorla, J. I.; Madan-Rodriguez, C.; Martin-Oliva, R.

    2013-07-01

    Has been defined the status initial reference of the lineal mini-accelerator Intrabeam PRS 500. The alternative worksheet in times of treatment provides an additional verification. The system is validated for clinical use. (Author)

  15. Electron beam dynamics in the long-pulse, high-current DARHT-II linear induction accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Carl A [Los Alamos National Laboratory; Abeyta, Epifanio O [Los Alamos National Laboratory; Aragon, Paul [Los Alamos National Laboratory; Archuleta, Rita [Los Alamos National Laboratory; Cook, Gerald [Los Alamos National Laboratory; Dalmas, Dale [Los Alamos National Laboratory; Esquibel, Kevin [Los Alamos National Laboratory; Gallegos, Robert A [Los Alamos National Laboratory; Garnett, Robert [Los Alamos National Laboratory; Harrison, James F [Los Alamos National Laboratory; Johnson, Jeffrey B [Los Alamos National Laboratory; Jacquez, Edward B [Los Alamos National Laboratory; Mccuistian, Brian T [Los Alamos National Laboratory; Montoya, Nicholas A [Los Alamos National Laboratory; Nath, Subrato [Los Alamos National Laboratory; Nielsen, Kurt [Los Alamos National Laboratory; Oro, David [Los Alamos National Laboratory; Prichard, Benjamin [Los Alamos National Laboratory; Rowton, Lawrence [Los Alamos National Laboratory; Sanchez, Manolito [Los Alamos National Laboratory; Scarpetti, Raymond [Los Alamos National Laboratory; Schauer, Martin M [Los Alamos National Laboratory; Seitz, Gerald [Los Alamos National Laboratory; Schulze, Martin [Los Alamos National Laboratory; Bender, Howard A [Los Alamos National Laboratory; Broste, William B [Los Alamos National Laboratory; Carlson, Carl A [Los Alamos National Laboratory; Frayer, Daniel K [Los Alamos National Laboratory; Johnson, Douglas E [Los Alamos National Laboratory; Tom, C Y [Los Alamos National Laboratory; Williams, John [Los Alamos National Laboratory; Hughes, Thomas [Los Alamos National Laboratory; Anaya, Richard [LLNL; Caporaso, George [LLNL; Chambers, Frank [LLNL; Chen, Yu - Jiuan [LLNL; Falabella, Steve [LLNL; Guethlein, Gary [LLNL; Raymond, Brett [LLNL; Richardson, Roger [LLNL; Trainham, C [NSTEC/STL; Watson, Jim [LLNL; Weir, John [LLNL; Genoni, Thomas [VOSS; Toma, Carsten [VOSS

    2009-01-01

    The DARHT-II linear induction accelerator (LIA) now accelerates 2-kA electron beams to more than 17 MeV. This LIA is unique in that the accelerated current pulse width is greater than 2 microseconds. This pulse has a flat-top region where the final electron kinetic energy varies by less than 1% for more than 1.5 microseconds. The long risetime of the 6-cell injector current pulse is 0.5 {micro}s, which can be scraped off in a beam-head cleanup zone before entering the 68-cell main accelerator. We discuss our experience with tuning this novel accelerator; and present data for the resulting beam transport and dynamics. We also present beam stability data, and relate these to previous stability experiments at lower current and energy.

  16. Linear and Nonlinear Heart Rate Variability Indexes in Clinical Practice

    Directory of Open Access Journals (Sweden)

    Buccelletti Francesco

    2012-01-01

    Full Text Available Biological organisms have intrinsic control systems that act in response to internal and external stimuli maintaining homeostasis. Human heart rate is not regular and varies in time and such variability, also known as heart rate variability (HRV, is not random. HRV depends upon organism's physiologic and/or pathologic state. Physicians are always interested in predicting patient's risk of developing major and life-threatening complications. Understanding biological signals behavior helps to characterize patient's state and might represent a step toward a better care. The main advantage of signals such as HRV indexes is that it can be calculated in real time in noninvasive manner, while all current biomarkers used in clinical practice are discrete and imply blood sample analysis. In this paper HRV linear and nonlinear indexes are reviewed and data from real patients are provided to show how these indexes might be used in clinical practice.

  17. SU-E-T-190: First Integration of Steriotactic Radiotherapy Planning System Iplan with Elekta Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Biplab, S; Soumya, R; Paul, S; Jassal, K; Munshi, A; Giri, U; Kumar, V; Roy, S; Ganesh, T; Mohanti, B

    2014-06-01

    Purpose: For the first time in the world, BrainLAB has integrated its iPlan treatment planning system for clinical use with Elekta linear accelerator (Axesse with a Beam Modulator). The purpose of this study was to compare the calculated and measured doses with different chambers to establish the calculation accuracy of iPlan system. Methods: The iPlan has both Pencil beam (PB) and Monte Carlo (MC) calculation algorithms. Beam data include depth doses, profiles and output measurements for different field sizes. Collected data was verified by vendor and beam modelling was done. Further QA tests were carried out in our clinic. Dose calculation accuracy verified point, volumetric dose measurement using ion chambers of different volumes (0.01cc and 0.125cc). Planner dose verification was done using diode array. Plans were generated in iPlan and irradiated in Elekta Axesse linear accelerator. Results: Dose calculation accuracies verified using ion chamber for 6 and 10 MV beam were 3.5+/-0.33(PB), 1.7%+/-0.7(MC) and 3.9%+/-0.6(PB), 3.4%+/-0.6(MC) respectively. Using a pin point chamber, dose calculation accuracy for 6MV and 10MV was 3.8%+/-0.06(PB), 1.21%+/-0.2(MC) and 4.2%+/-0.6(PB), 3.1%+/-0.7(MC) respectively. The calculated planar dose distribution for 10.4×10.4 cm2 was verified using a diode array and the gamma analysis for 2%-2mm criteria yielded pass rates of 88 %(PB) and 98.8%(MC) respectively. 3mm-3% yields 100% passing for both MC and PB algorithm. Conclusion: Dose calculation accuracy was found to be within acceptable limits for MC for 6MV beam. PB for both beams and MC for 10 MV beam were found to be outside acceptable limits. The output measurements were done twice for conformation. The lower gamma matching was attributed to meager number of measured profiles (only two profiles for PB) and coarse measurement resolution for diagonal profile measurement (5mm). Based on these measurements we concluded that 6 MV MC algorithm is suitable for patient treatment.

  18. Accelerating Scientific Applications using High Performance Dense and Sparse Linear Algebra Kernels on GPUs

    KAUST Repository

    Abdelfattah, Ahmad

    2015-01-15

    High performance computing (HPC) platforms are evolving to more heterogeneous configurations to support the workloads of various applications. The current hardware landscape is composed of traditional multicore CPUs equipped with hardware accelerators that can handle high levels of parallelism. Graphical Processing Units (GPUs) are popular high performance hardware accelerators in modern supercomputers. GPU programming has a different model than that for CPUs, which means that many numerical kernels have to be redesigned and optimized specifically for this architecture. GPUs usually outperform multicore CPUs in some compute intensive and massively parallel applications that have regular processing patterns. However, most scientific applications rely on crucial memory-bound kernels and may witness bottlenecks due to the overhead of the memory bus latency. They can still take advantage of the GPU compute power capabilities, provided that an efficient architecture-aware design is achieved. This dissertation presents a uniform design strategy for optimizing critical memory-bound kernels on GPUs. Based on hierarchical register blocking, double buffering and latency hiding techniques, this strategy leverages the performance of a wide range of standard numerical kernels found in dense and sparse linear algebra libraries. The work presented here focuses on matrix-vector multiplication kernels (MVM) as repre- sentative and most important memory-bound operations in this context. Each kernel inherits the benefits of the proposed strategies. By exposing a proper set of tuning parameters, the strategy is flexible enough to suit different types of matrices, ranging from large dense matrices, to sparse matrices with dense block structures, while high performance is maintained. Furthermore, the tuning parameters are used to maintain the relative performance across different GPU architectures. Multi-GPU acceleration is proposed to scale the performance on several devices. The

  19. Output trends, characteristics, and measurements of three megavoltage radiotherapy linear accelerators.

    Science.gov (United States)

    Hossain, Murshed

    2014-07-08

    The purpose of this study is to characterize and understand the long-term behavior of the output from megavoltage radiotherapy linear accelerators. Output trends of nine beams from three linear accelerators over a period of more than three years are reported and analyzed. Output, taken during daily warm-up, forms the basis of this study. The output is measured using devices having ion chambers. These are not calibrated by accredited dosimetry laboratory, but are baseline-compared against monthly output which is measured using calibrated ion chambers. We consider the output from the daily check devices as it is, and sometimes normalized it by the actual output measured during the monthly calibration of the linacs. The data show noisy quasi-periodic behavior. The output variation, if normalized by monthly measured "real' output, is bounded between ± 3%. Beams of different energies from the same linac are correlated with a correlation coefficient as high as 0.97, for one particular linac, and as low as 0.44 for another. These maximum and minimum correlations drop to 0.78 and 0.25 when daily output is normalized by the monthly measurements. These results suggest that the origin of these correlations is both the linacs and the daily output check devices. Beams from different linacs, independent of their energies, have lower correlation coefficient, with a maximum of about 0.50 and a minimum of almost zero. The maximum correlation drops to almost zero if the output is normalized by the monthly measured output. Some scatter plots of pairs of beam output from the same linac show band-like structures. These structures are blurred when the output is normalized by the monthly calibrated output. Fourier decomposition of the quasi-periodic output is consistent with a 1/f power law. The output variation appears to come from a distorted normal distribution with a mean of slightly greater than unity. The quasi-periodic behavior is manifested in the seasonally averaged output

  20. Studies and measurements of linear coupling and nonlinearities in hadron circular accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Franchi, A.

    2006-07-01

    In this thesis a beam-based method has been developed to measure the strength and the polarity of corrector magnets (skew quadrupoles and sextupoles) in circular accelerators. The algorithm is based on the harmonic analysis (via FFT) of beam position monitor (BPM) data taken turn by turn from an accelerator in operation. It has been shown that, from the differences of the spectral line amplitudes between two consecutive BPMs, both the strength and the polarity of non-linear elements placed in between can be measured. The method has been successfully tested using existing BPM data from the SPS of CERN. A second beam-based method has been studied for a fast measurement and correction of betatron coupling driven by skew quadrupole field errors and tilted focusing quadrupoles. In this thesis it has been shown how the correction for minimizing the coupling stop band C can be performed in a single machine cycle from the harmonic analysis of multi-BPM data. The method has been successfully applied to RHIC. A third theoretical achievement is a new description of the betatron motion close to the difference resonance in presence of linear coupling. New formulae describing the exchange of RMS resonances have been derived here making use of Lie algebra providing a better description of the emittance behavior. A new way to decouple the equations of motion and explicit expressions for the individual single particle invariants have been found. For the first time emittance exchange studies have been carried out in the SIS-18 of GSI. Applications of this manipulation are: emittance equilibration under consideration for future operations of the SIS-18 as booster for the SIS-100; emittance transfer during multi-turn injection to improve the efficiency and to protect the injection septum in high intensity operations, by shifting part of the horizontal emittance into the vertical plane. Multi-particle simulations with 2D PIC space-charge solver have been run to infer heuristic scaling

  1. Development of a dual-pulse RF driver for an S-band (= 2856 MHz) RF electron linear accelerator

    Science.gov (United States)

    Cha, Sungsu; Kim, Yujong; Lee, Byeong-No; Lee, Byung Cheol; Cha, Hyungki; Ha, Jang Ho; Park, Hyung Dal; Lee, Seung Hyun; Kim, Hui Su; Buaphad, Pikad

    2016-04-01

    The radiation equipment research division of Korea Atomic Energy Research Institute has developed a Container Inspection System (CIS) using a Radio Frequency (RF) electron linear accelerator for port security. The primary purpose of the CIS is to detect nuclear materials and explosives, as well country-specific prohibited substances, e.g., smuggled. The CIS consists of a 9/6 MeV dualenergy electron linear accelerator for distinguishing between organic and inorganic materials. The accelerator consists of an electron gun, an RF accelerating structure, an RF driver, a modulator, electromagnets, a cooling system, a X-ray generating target, X-ray collimator, a detector, and a container moving system. The RF driver is an important part of the configuration because it is the RF power source: it supplies the RF power to the accelerating structure. A unique aspect of the RF driver is that it generates dual RF power to generate dual energy (9/6 MeV). The advantage of this RF driver is that it can allow the pulse width to vary and can be used to obtain a wide range of energy output, and pulse repetition rates up to 300 Hz. For this reason, 140 W (5 MW - 9 MeV) and 37 W (3.4 MW - 6 MeV) power outputs are available independently. A high power test for 20 minutes demonstrate that stable dual output powers can be generated. Moreover, the dual power can be applied to the accelerator which has stable accelerator operation. In this paper, the design, fabrication and high power test of the RF driver for the RF electron linear accelerator (linac) are presented.

  2. Accuracy evaluation of the optical surface monitoring system on EDGE linear accelerator in a phantom study.

    Science.gov (United States)

    Mancosu, Pietro; Fogliata, Antonella; Stravato, Antonella; Tomatis, Stefano; Cozzi, Luca; Scorsetti, Marta

    2016-01-01

    Frameless stereotactic radiosurgery (SRS) requires dedicated systems to monitor the patient position during the treatment to avoid target underdosage due to involuntary shift. The optical surface monitoring system (OSMS) is here evaluated in a phantom-based study. The new EDGE linear accelerator from Varian (Varian, Palo Alto, CA) integrates, for cranial lesions, the common cone beam computed tomography (CBCT) and kV-MV portal images to the optical surface monitoring system (OSMS), a device able to detect real-time patient׳s face movements in all 6 couch axes (vertical, longitudinal, lateral, rotation along the vertical axis, pitch, and roll). We have evaluated the OSMS imaging capability in checking the phantoms׳ position and monitoring its motion. With this aim, a home-made cranial phantom was developed to evaluate the OSMS accuracy in 4 different experiments: (1) comparison with CBCT in isocenter location, (2) capability to recognize predefined shifts up to 2° or 3cm, (3) evaluation at different couch angles, (4) ability to properly reconstruct the surface when the linac gantry visually block one of the cameras. The OSMS system showed, with a phantom, to be accurate for positioning in respect to the CBCT imaging system with differences of 0.6 ± 0.3mm for linear vector displacement, with a maximum rotational inaccuracy of 0.3°. OSMS presented an accuracy of 0.3mm for displacement up to 1cm and 1°, and 0.5mm for larger displacements. Different couch angles (45° and 90°) induced a mean vector uncertainty < 0.4mm. Coverage of 1 camera produced an uncertainty < 0.5mm. Translations and rotations of a phantom can be accurately detect with the optical surface detector system.

  3. Total skin electron therapy at two energies on a linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Turner, J.R.; Wymme, C.J. [Christchurch Hospital (New Zealand); Hugtenburg, R.P. [Canterbury Univ., Christchurch (New Zealand). Dept. of Physics

    1995-12-01

    Extensive measurements have been performed on the Varian 2100c linear accelerator with a water equivalent phantom, cylindrical phantoms and an anthropomorphic phantom to validate the 12 beam technique and to measure calibration factors with respect to total skin electron therapy (TEST) for the treatment of Mycosis Fungoides. The technique was developed at 2.5 MeV and 3.5 MeV (mean energy at the surface) with the energy degrading screen at 30 cm from the patient. Field flatness over the treatment area was within {+-} 3% with no significant regional variation of energy. The bremstrahlung contamination was 0.06 - 1.2 %. The absolute calibration of absorbed dose to the patient required the measurement of the ratio skin dose to calibration point dose, this was confirmed by measurements with a parallel plate ionization chamber and thermoluminescence dosimetry. The results indicate the care that must be taken with ionization chamber measurements under TSET condition to avoid erroneous readings due to the `polarity effect`. A protocol is suggested for the practical implementation and quality assurance of the technique. The results of two successful treatments are presented and compared with the predicted results from phantoms. 18 refs., 2 tabs., 10 figs.

  4. Linear induction accelerators at the Los Alamos National Laboratory DARHT facility

    Energy Technology Data Exchange (ETDEWEB)

    Nath, Subrata [Los Alamos National Laboratory

    2010-09-07

    The Dual-Axis Radiographic Hydrodynamic Test Facility (DARHT) at Los Alamos National Laboratory consists of two linear induction accelerators at right angles to each other. The First Axis, operating since 1999, produces a nominal 20-MeV, 2-kA single beam-pulse with 60-nsec width. In contrast, the DARHT Second Axis, operating since 2008, produces up to four pulses in a variable pulse format by slicing micro-pulses out of a longer {approx}1.6-microseconds (flat-top) pulse of nominal beam-energy and -current of 17 MeV and 2 kA respectively. Bremsstrahlung x-rays, shining on a hydro-dynamical experimental device, are produced by focusing the electron beam-pulses onto a high-Z target. Variable pulse-formats allow for adjustment of the pulse-to-pulse doses to record a time sequence of x-ray images of the explosively driven imploding mock device. Herein, we present a sampling of the numerous physics and engineering aspects along with the current status of the fully operational dual axes capability. First successful simultaneous use of both the axes for a hydrodynamic experiment was achieved in 2009.

  5. Comparison of dosimetric characteristics of Siemens virtual and physical wedges for ONCOR linear accelerator

    Directory of Open Access Journals (Sweden)

    Attalla Ehab

    2010-01-01

    Full Text Available Dosimetric properties of virtual wedge (VW and physical wedge (PW in 6- and 10-MV photon beams from a Siemens ONCOR linear accelerator, including wedge factors, depth doses, dose profiles, peripheral doses, are compared. While there is a great difference in absolute values of wedge factors, VW factors (VWFs and PW factors (PWFs have a similar trend as a function of field size. PWFs have stronger depth dependence than VWF due to beam hardening in PW fields. VW dose profiles in the wedge direction, in general, match very well with those of PW, except in the toe area of large wedge angles with large field sizes. Dose profiles in the nonwedge direction show a significant reduction in PW fields due to off-axis beam softening and oblique filtration. PW fields have significantly higher peripheral doses than open and VW fields. VW fields have similar surface doses as the open fields, while PW fields have lower surface doses. Surface doses for both VW and PW increase with field size and slightly with wedge angle. For VW fields with wedge angles 45° and less, the initial gap up to 3 cm is dosimetrically acceptable when compared to dose profiles of PW. VW fields in general use less monitor units than PW fields.

  6. Production Of Intense, Tunable, Quasi-monochromatic X- Rays Using The Rpi Linear Accelerator

    CERN Document Server

    Sones, B A

    2004-01-01

    This research investigated the production of parametric X-rays (PXR) using the 60-MeV electron linear accelerator at Rensselaer Polytechnic Institute. PXR is an intense, energy tunable, and polarized X-ray source derived from the interaction of relativistic electrons and the periodic structure of crystal materials. In this work, PXR photon yields and the associated bremsstrahlung background were characterized for graphite, LiF, Si, Ge, Cu, and W target crystals. A model that considers the experimental geometry and crystal mosaicity was employed to predict PXR energy broadening. Measured energy linewidths consistently agreed with predicted values except in cases using poor quality graphite in which the mosaicity was greater than the PXR characteristic angle, 8.5 mrad for 60 MeV electrons. When the predicted energy linewidth was more narrow than our Si X-ray detector resolution, a near-absorption edge transmission technique was used to measure the PXR energy linewidth for Si(400) FWHM of 134 eV at 9.0 keV (2%) ...

  7. Retrospective study on therapy options of brain metastases surgery versus stereotactic radiotherapy with the linear accelerator

    CERN Document Server

    Fortunati, M K S

    2001-01-01

    Background: in the therapy of brain metastases there has been a great progress in the last years. It was shown, that more aggressive therapies can not only extend the survival of the patients, but also improve quality of life. The major question of this study was, whether surgery or stereotactic radiotherapy with the linear accelerator show better results in behalf of the survival. Beside this major question many parameters regarding the patient or his primary cancer were examined. Methods: from the 1st of January 1995 until the 30th of June 2000 233 patients with one or more brain metastases have been treated in the Wagner Jauregg Landesnervenkrankenhaus Oberoesterreich (WJ LNKH OeO). The LINAC has been established on the 1st of July 1997. The patients have been distributed in three groups: 1. LINAC-group: 81 patients have been treated from the 1st of July 1997 until the 30th of June 2000 with the LINAC. 2. Surgery-group: 81 patients have been operated from the 1st of July 1997 until the 30th June 2000. 3 Co...

  8. Nonlinear combination parametric resonance of axially accelerating viscoelastic strings constituted by the standard linear solid model

    Institute of Scientific and Technical Information of China (English)

    LIM; C.W.

    2010-01-01

    Nonlinear combination parametric resonance is investigated for an axially accelerating viscoelastic string.The governing equation of in-planar motion of the string is established by introducing a coordinate transform in the Eulerian equation of a string with moving boundaries.The string under investigation is constituted by the standard linear solid model in which the material,not partial,time derivative was used.The governing equation leads to the Mote model for transverse vibration by omitting the longitudinal component and higher order terms.The Kirchhoff model is derived from the Mote model by replacing the tension with the averaged tension over the string.The two models are respectively analyzed via the method of multiple scales for principal parametric resonance.The amplitudes and the existence conditions of steady-state response and its stability can be numerically determined.Numerical calculations demonstrate the effects of the string material parameters,the initial tension,and the axial speed fluctuation amplitude.The outcomes of the two models are qualitatively and quantitatively compared.

  9. Development Of A Four Cavity Second-harmonic Gyroklystron As Driver For A Linear Accelerator

    CERN Document Server

    Gouveia, E S

    2004-01-01

    Gyroklystrons are microwave amplifiers that combine the multi-cavity configuration of a klystron with the energy extraction mechanism of the cyclotron maser instability. These devices have been studied at the University of Maryland for several years. This work is focused on the development of a 17.14 GHz four-cavity frequency-doubling gyroklystron circuit. This device was designed specifically to drive a high gradient linear accelerator recently developed by the Haimson Corporation. The gyroklystron was designed using the code MAGYKL, yielding a predicted output power of 87 MW for an input drive power of 250 W, with a velocity pitch ratio (α) of 1.4. The tube was later fabricated, and underwent a series of experimental tests to evaluate its performance. The highest peak power observed was 18.5 ± 1.7 MW, corresponding to an efficiency of 7.0% and a gain of 24.0 dB. This result fell short of the theoretical design, yet it was consistent with the low value of the velocity pitch ratio (&a...

  10. Monte Carlo simulations for 20 MV X-ray spectrum reconstruction of a linear induction accelerator

    Institute of Scientific and Technical Information of China (English)

    WANG Yi; LI Qin; JIANG Xiao-Guo

    2012-01-01

    To study the spectrum reconstruction of the 20 MV X-ray generated by the Dragon-I linear induction accelerator,the Monte Carlo method is applied to simulate the attenuations of the X-ray in the attenuators of different thicknesses and thus provide the transmission data.As is known,the spectrum estimation from transmission data is an ill-conditioned problem.The method based on iterative perturbations is employed to derive the X-ray spectra,where initial guesses are used to start the process.This algorithm takes into account not only the minimization of the differences between the measured and the calculated transmissions but also the smoothness feature of the spectrum function.In this work,various filter materials are put to use as the attenuator,and the condition for an accurate and robust solution of the X-ray spectrum calculation is demonstrated.The influences of the scattering photons within different intervals of emergence angle on the X-ray spectrum reconstruction are also analyzed.

  11. Radio to $\\gamma$-Ray Emission from Shell-type Supernova Remnants Predictions from Non-linear Shock Acceleration Models

    CERN Document Server

    Baring, M G; Reynolds, S P; Grenier, I; Goret, P; Baring, Matthew G.; Ellison, Donald C.; Reynolds, Stephen P; Grenier, Isabelle; Goret, Philippe

    1999-01-01

    Supernova remnants (SNRs) are widely believed to be the principal source of galactic cosmic rays. Such energetic particles can produce gamma-rays and lower energy photons via interactions with the ambient plasma. In this paper, we present results from a Monte Carlo simulation of non-linear shock structure and acceleration coupled with photon emission in shell-like SNRs. These non-linearities are a by-product of the dynamical influence of the accelerated cosmic rays on the shocked plasma and result in distributions of cosmic rays which deviate from pure power-laws. Such deviations are crucial to acceleration efficiency and spectral considerations, producing GeV/TeV intensity ratios that are quite different from test particle predictions. The Sedov scaling solution for SNR expansions is used to estimate important shock parameters for input into the Monte Carlo simulation. We calculate ion and electron distributions that spawn neutral pion decay, bremsstrahlung, inverse Compton, and synchrotron emission, yieldin...

  12. Manual Linear Movements to Assess Spasticity in a Clinical Setting

    Science.gov (United States)

    Marinelli, Lucio; Trompetto, Carlo; Mori, Laura; Vigo, Gabriele; Traverso, Elisabetta; Colombano, Federica; Abbruzzese, Giovanni

    2013-01-01

    In a clinical setting, where motor-driven systems are not readily available, the major difficulty in the assessment of the stretch reflex lies in the control of passive limb displacement velocity. A potential approach to this problem arises from the use of manual sinusoidal movements (made by continuous alternating flexions and extensions) paced by an external stimulus. Unfortunately, there are conditions in which sinusoidal movements induce interfering phenomena such as the shortening reaction or postactivation depression. In the present paper, a novel manual method to control the velocity of passive linear movements is described and the results obtained from both healthy subjects and spastic patients are reported. This method is based on the synchronisation of movements with tones played by a metronome at different speeds. In a first set of experiments performed in healthy subjects, we demonstrated consistent control of velocity during passive limb movements using this method. Four joints usually examined during muscle tone assessment were tested: wrist, elbow, knee and ankle joints. Following this, we conducted a longitudinal assessment of the stretch reflex amplitude in wrist flexor muscles in patients with spasticity treated with botulinum toxin type A. The evaluators were not only able to vary the movement velocity based on the metronome speed, but also could reproduce the respective speeds two weeks later, despite the changing degree of hypertonia. This method is easy to perform in a clinical setting and hardware requirements are minimal, making it an attractive and robust procedure for the widespread clinical assessment of reflex hypertonia. PMID:23335966

  13. Occupational doses due to photoneutrons in medical linear accelerators rooms; Doses ocupacionais devido a neutrons em salas de aceleradores lineares de uso medico

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Alessandro Facure Neves de Salles

    2006-04-15

    Medical linear accelerators, with maximum photon energies above 10 MeV, are becoming of common use in Brazil. Although desirable in the therapeutic point of view, the increase in photon energies causes the generation of undesired neutrons, which are produced through nuclear reactions between photons and the high Z target nuclei of the materials that constitute the accelerator head. In this work, MCNP simulation was undertaken to examine the neutron equivalent doses around the accelerators head and at the entrance of medical linear accelerators treatment rooms, some of them licensed in Brazil by the National Regulatory Agency (CNEN). The simulated neutron dose equivalents varied between 2 e 26 {mu} Sv/Gy{sub RX}, and the results were compared with calculations performed with the use of some semi-empirical equations found in literature. It was found that the semi-empirical equations underestimate the simulated neutron doses in the majority of the cases, if compared to the simulated values, suggesting that these equations must be revised, due to the increasing number of high energy machines in the country. (author)

  14. Commissioning of a linear accelerator to execute volumetric modulated arc therapy; Comissionamento de um acelerador linear para realizacao da radioterapia em arco modulada volumetricamente

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Leandro R.; Santos, Gabriela R.; Menegussi, Gisela; Silva, Marco A.; Passaro, Anderson M.; Rodrigues, Laura N., E-mail: leandrorg11@hotmail.com [Instituto do Cancer do Estado de Sao Paulo (ICESP), Sao Paulo, SP (Brazil)

    2013-08-15

    Radiotherapy techniques like VMAT allow complex dose distributions modulating the beam intensity within the irradiation field from the handling of multi-blade collimators, variations in dose rate, different speeds of rotation of the gantry and collimator angle allowing greater conformation of the dose to the tumor volume and a lower dose to healthy tissues. To ensure proper dose delivery, the linear particle accelerator must be able to monitor and perform all the variation in these parameters simultaneously. In this work dosimetric tests obtained in the literature that aims to commission, implement and ensure the quality of VMAT treatments were performed performed in the Institute of Cancer of Sao Paulo State (ICESP). From the results obtained it was established a program of quality control for the linear accelerator studied. The linearity and stability response of ionization chamber monitoring, leafs accuracy positioning, flatness and symmetry of beam to VMAT irradiations were evaluated. The obtained results are in agreement with the literature. It can be concluded that the accelerator studied is able to satisfactorily control the variation of all necessary parameters to perform the VMAT treatments. (author)

  15. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans.

    Science.gov (United States)

    Saenz, Daniel L; Paliwal, Bhudatt R; Bayouth, John E

    2014-04-01

    ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 (Co-60) with 0.35 Tesla magnetic resonance imaging (MRI) allows for magnetic resonance (MR)-guided intensity-modulated radiation therapy (IMRT) delivery with multiple beams. This study investigated head and neck, lung, and prostate treatment plans to understand what is possible on ViewRay to narrow focus toward sites with optimal dosimetry. The goal is not to provide a rigorous assessment of planning capabilities, but rather a first order demonstration of ViewRay planning abilities. Images, structure sets, points, and dose from treatment plans created in Pinnacle for patients in our clinic were imported into ViewRay. The same objectives were used to assess plan quality and all critical structures were treated as similarly as possible. Homogeneity index (HI), conformity index (CI), and volume receiving conformity increase for lung. The volume receiving 20% of the prescription dose increased 2-8% for head and neck and up to 4% for lung and prostate. Overall, for head and neck Co-60 ViewRay treatments planned with its Monte Carlo treatment planning software were comparable with 6 MV plans computed with convolution superposition algorithm on Pinnacle treatment planning system.

  16. Small field detector correction factors: effects of the flattening filter for Elekta and Varian linear accelerators.

    Science.gov (United States)

    Tyler, Madelaine K; Liu, Paul Z Y; Lee, Christopher; McKenzie, David R; Suchowerska, Natalka

    2016-05-08

    Flattening filter-free (FFF) beams are becoming the preferred beam type for stereotactic radiosurgery (SRS) and stereotactic ablative radiation therapy (SABR), as they enable an increase in dose rate and a decrease in treatment time. This work assesses the effects of the flattening filter on small field output factors for 6 MV beams generated by both Elekta and Varian linear accelerators, and determines differences between detector response in flattened (FF) and FFF beams. Relative output factors were measured with a range of detectors (diodes, ionization cham-bers, radiochromic film, and microDiamond) and referenced to the relative output factors measured with an air core fiber optic dosimeter (FOD), a scintillation dosimeter developed at Chris O'Brien Lifehouse, Sydney. Small field correction factors were generated for both FF and FFF beams. Diode measured detector response was compared with a recently published mathematical relation to predict diode response corrections in small fields. The effect of flattening filter removal on detector response was quantified using a ratio of relative detector responses in FFF and FF fields for the same field size. The removal of the flattening filter was found to have a small but measurable effect on ionization chamber response with maximum deviations of less than ± 0.9% across all field sizes measured. Solid-state detectors showed an increased dependence on the flattening filter of up to ± 1.6%. Measured diode response was within ± 1.1% of the published mathematical relation for all fields up to 30 mm, independent of linac type and presence or absence of a flattening filter. For 6 MV beams, detector correction factors between FFF and FF beams are interchangeable for a linac between FF and FFF modes, providing that an additional uncertainty of up to ± 1.6% is accepted.

  17. Treatment vault shielding for a flattening filter-free medical linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kry, Stephen F; Howell, Rebecca M; Polf, Jerimy; Mohan, Radhe; Vassiliev, Oleg N [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States)], E-mail: sfkry@mdanderson.org

    2009-03-07

    The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target current requirements were determined from treatment planning studies of several disease sites with, and without, the flattening filter. The flattened beam shielding data were compared to data published in NCRP Report No. 151, and the unflattened beam shielding data were presented relative to the NCRP data. Finally, the shielding requirements for a typical treatment vault were determined for a single-energy (6 MV) linac and a dual-energy (6 MV/18 MV) linac. With the exception of large-angle patient scatter fractions and wall scatter fractions, the vault shielding parameters were reduced when the flattening filter was removed. Much of this reduction was consistent with the reduced average energy of the FFF beams. Primary beam TVLs were reduced by 12%, on average, and small-angle scatter fractions were reduced by up to 30%. Head leakage was markedly reduced because less integral target current was required to deliver the target dose. For the treatment vault examined in the current study, removal of the flattening filter reduced the required thickness of the primary and secondary barriers by 10-20%, corresponding to 18 m{sup 3} less concrete to shield the single-energy linac and 36 m{sup 3} less concrete to shield the dual-energy linac. Thus, a shielding advantage was found when the linac was operated without the flattening filter. This translates into a reduction in occupational exposure and/or the cost and space of shielding.

  18. A Comparison Between GATE and MCNPX Monte Carlo Codes in Simulation of Medical Linear Accelerator

    Science.gov (United States)

    Sadoughi, Hamid-Reza; Nasseri, Shahrokh; Momennezhad, Mahdi; Sadeghi, Hamid-Reza; Bahreyni-Toosi, Mohammad-Hossein

    2014-01-01

    Radiotherapy dose calculations can be evaluated by Monte Carlo (MC) simulations with acceptable accuracy for dose prediction in complicated treatment plans. In this work, Standard, Livermore and Penelope electromagnetic (EM) physics packages of GEANT4 application for tomographic emission (GATE) 6.1 were compared versus Monte Carlo N-Particle eXtended (MCNPX) 2.6 in simulation of 6 MV photon Linac. To do this, similar geometry was used for the two codes. The reference values of percentage depth dose (PDD) and beam profiles were obtained using a 6 MV Elekta Compact linear accelerator, Scanditronix water phantom and diode detectors. No significant deviations were found in PDD, dose profile, energy spectrum, radial mean energy and photon radial distribution, which were calculated by Standard and Livermore EM models and MCNPX, respectively. Nevertheless, the Penelope model showed an extreme difference. Statistical uncertainty in all the simulations was MCNPX, Standard, Livermore and Penelope models, respectively. Differences between spectra in various regions, in radial mean energy and in photon radial distribution were due to different cross section and stopping power data and not the same simulation of physics processes of MCNPX and three EM models. For example, in the Standard model, the photoelectron direction was sampled from the Gavrila-Sauter distribution, but the photoelectron moved in the same direction of the incident photons in the photoelectric process of Livermore and Penelope models. Using the same primary electron beam, the Standard and Livermore EM models of GATE and MCNPX showed similar output, but re-tuning of primary electron beam is needed for the Penelope model. PMID:24696804

  19. Development and Dosimetric Characterization of a Tissue Substitute (Bolus) For Use in Linear Accelerator Electron Radiotherapy

    Science.gov (United States)

    Estrada Trujillo, Jorge; Villaseñor Navarro, Luis Felipe; Mitsoura, Eleni

    2003-09-01

    We propose the design of a new custom made material, to be used as a tissue substitute in external beam electron radiotherapy, based on cotton fabric and beeswax. Due to its inexpensive, easy preparation, constant thickness, flexibility, uniform density and physical properties similar to those of soft tissue, this bolus will insure personalized optimal dose build up and dose distribution in irregular treatment regions. Materials and Methods: We used commercial Campeche beeswax and 100% cotton fabric to prepare the bolus. Beeswax's physical characteristics were determined by thermal and density analysis. Its chemical properties are to be determined by electronic microcopy. We performed quality control tests and calibration of the Varian 2100C linear accelerator. The tissue equivalence of the material is established for a range of electron energies (6, 9, 12, 16, 20 MeV) using a water equivalent solid phantom (PTW; Freiburg, Germany) and a plane parallel ionization chamber (PTW) associated to a PTW electrometer. Results: Beeswax's absolute density was found to be 0.9181g/ml at 21°C, with a melting point of 45°C. For the bolus elaboration, the cotton fabric was soaked in liquid beeswax and thin sheets of approximately 1 mm were obtained. These presented high flexibility, physical stability (color, texture, thickness) and homogeneity. Determination of this dosimetric characteristics and equivalent thickness are still in process. Discussion and conclusions: Our preliminary results suggest that the tissue substitute is easily made, inexpensive to produce, molds well to the treatment area and its positioning is easy and reproducible over the course of the treatment. So we consider that it's a good alternative to the commercial bolus.

  20. Evaluation of the small field of for the detector type medical linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Woon; Jung, Kang Kyo; Cho, Pyong Kon [Dept. of Radiological Science, Catholic University of DaeGu, Daegu (Korea, Republic of); Shin, Gwi Soon [Dept. of Radiological Technology, Songho College, Hoengseong (Korea, Republic of)

    2016-06-15

    Recently linear accelerator of radiation therapy intensity modulated radiation therapy, stereotactic radiation therapy are widely used. Such radiation treatment techniques are generally difficult to exclude the small field by using the inverse treatment plan. It is necessary to dose an accurate measurement of characteristics of the small field. Thus, using different detectors to measure the volume of the effective percentage depth dose, beam profile, and the output factor of the small field was to evaluate the dose characteristics of each detector. Experimental results for the X-ray beam 6 MV energy beam quality(PDD20/PDD10) is 10 × 10 cm{sup 2} Diode detector is as high as 2.4% compared to Pinpoint detector. All field size to lesser effective volume of Diode detector shows that it is far better than other detectors by more than 50% of small penumbra, therefore spatial resolution far excellent. In field size 2 × 2 cm{sup 2} Semiflex detector was measured about 2% less than the other detector. Field size 1 × 1 cm{sup 2} is that there is no judgment about the validity show the difference between 20%. Field size 1 × 1 cm{sup 2} from the measured values of the Diode detector and Pinpoint detector showed a 13% difference. Less than field size 3 × 3 cm{sup 2} the feed to the difference between the output factor of the effective volume of the detector to be used for the effective volume available to the detector.

  1. Linear Accelerator-Based Radiosurgery Alone for Arteriovenous Malformation: More Than 12 Years of Observation

    Energy Technology Data Exchange (ETDEWEB)

    Matsuo, Takayuki, E-mail: takayuki@nagasaki-u.ac.jp; Kamada, Kensaku; Izumo, Tsuyoshi; Hayashi, Nobuyuki; Nagata, Izumi

    2014-07-01

    Purpose: Although radiosurgery is an accepted treatment method for intracranial arteriovenous malformations (AVMs), its long-term therapeutic effects have not been sufficiently evaluated, and many reports of long-term observations are from gamma-knife facilities. Furthermore, there are few reported results of treatment using only linear accelerator (LINAC)-based radiosurgery (LBRS). Methods and Materials: Over a period of more than 12 years, we followed the long-term results of LBRS treatment performed in 51 AVM patients. Results: The actuarial obliteration rates, after a single radiosurgery session, at 3, 5, 10, and 15 years were 46.9%, 54.0%, 64.4%, and 68.0%, respectively; when subsequent radiosurgeries were included, the rates were 46.9%, 61.3%, 74.2%, and 90.3%, respectively. Obliteration rates were significantly related to target volumes ≥4 cm{sup 3}, marginal doses ≥12 Gy, Spetzler-Martin grades (1 vs other), and AVM scores ≥1.5; multivariate analyses revealed a significant difference for target volumes ≥4 cm{sup 3}. The postprocedural actuarial symptomatic radiation injury rates, after a single radiation surgery session, at 5, 10, and 15 years were 12.3%, 16.8%, and 19.1%, respectively. Volumes ≥4 cm{sup 3}, location (lobular or other), AVM scores ≥1.5, and the number of radiosurgery were related to radiation injury incidence; multivariate analyses revealed significant differences associated with volumes ≥4 cm{sup 3} and location (lobular or other). Conclusions: Positive results can be obtained with LBRS when performed with a target volume ≤4 cm{sup 3}, an AVM score ≤1.5, and ≥12 Gy radiation. Bleeding and radiation injuries may appear even 10 years after treatment, necessitating long-term observation.

  2. A collimated detection system for assessing leakage dose from medical linear accelerators at the patient plane.

    Science.gov (United States)

    Lonski, P; Taylor, M L; Franich, R D; Kron, T

    2014-03-01

    Leakage radiation from linear accelerators can make a significant contribution to healthy tissue dose in patients undergoing radiotherapy. In this work thermoluminescent dosimeters (LiF:Mg,Cu,P TLD chips) were used in a focused lead cone loaded with TLD chips for the purpose of evaluating leakage dose at the patient plane. By placing the TLDs at one end of a stereotactic cone, a focused measurement device is created; this was tested both in and out of the primary beam of a Varian 21-iX linac using 6 MV photons. Acrylic build up material of 1.2 cm thickness was used inside the cone and measurements made with either one or three TLD chips at a given distance from the target. Comparing the readings of three dosimeters in one plane inside the cone offered information regarding the orientation of the cone relative to a radiation source. Measurements in the patient plane with the linac gantry at various angles demonstrated that leakage dose was approximately 0.01% of the primary beam out of field when the cone was pointed directly towards the target and 0.0025% elsewhere (due to scatter within the gantry). No specific 'hot spots' (e.g., insufficient shielding or gaps at abutments) were observed. Focused cone measurements facilitate leakage dose measurements from the linac head directly at the patient plane and allow one to infer the fraction of leakage due to 'direct' photons (along the ray-path from the bremsstrahlung target) and that due to scattered photons.

  3. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'

    Energy Technology Data Exchange (ETDEWEB)

    Salter, Bill J; Sarkar, Vikren; Wang, Brian; Szegedi, Martin; Rassiah-Szegedi, Prema [Department of Radiation Oncology, University of Utah, Salt Lake City, UT (United States); Shukla, Himanshu, E-mail: bill.salter@hci.utah.edu [Oncology Care Systems Group, Siemens Medical Solutions (USA), 4040 Nelson Avenue, Concord, CA (United States)

    2011-04-07

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min{sup -1}) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  4. Screening Approach to the Activation of Soil and Contamination of Groundwater at Linear Proton Accelerator Sites

    CERN Document Server

    Otto, Thomas

    The activation of soil and the contamination of groundwater at proton accelerator sites with the radionuclides 3H and 22Na are estimated with a Monte-Carlo calculation and a conservative soil- and ground water model. The obtained radionuclide concentrations show that the underground environment of future accelerators must be adequately protected against a migration of activation products. This study is of particular importance for the proton driver accelerator in the planned EURISOL facility.

  5. Linear_Accelerator_C+6_Ions_as_Injector_for_a_Synchrotron, Intended for Hadrons Therapy

    CERN Document Server

    Dolya, S N

    2013-01-01

    We consider acceleration light ions by the field of a traveling-wave in a helical waveguide. The frequency of the accelerating RF field f = 100 MHz, generator power P = 2 MW. Ion focusing is provided by a solenoidal magnetic field with the intensity B = 3.5 Tesla. With increasing the accelerator length up to L = 15 m, the final energy of the ions can be increased up to a value of E = 7 MeV / nucleon.

  6. Responses to rotating linear acceleration vectors considered in relation to a model of the otolith organs. [human oculomotor response to transverse acceleration stress

    Science.gov (United States)

    Benson, A. J.; Barnes, G. R.

    1973-01-01

    Human subjects were exposed to a linear acceleration vector that rotated in the transverse plane of the skull without angular counterrotation. Lateral eye movements showed a sinusoidal change in slow phase velocity and an asymmetry or bias in the same direction as vector rotation. A model is developed that attributes the oculomotor response to otolithic mechanisms. It is suggested that the bias component is the manifestation of torsion of the statoconial plaque relative to the base of the utricular macula and that the sinusoidal component represents the translational oscillation of the statoconia. The model subsumes a hypothetical neural mechanism which allows x- and y-axis accelerations to be resolved. Derivation of equations of motion for the statoconial plaque in torsion and translation, which take into account forces acting in shear and normal to the macula, yield estimates of bias and sinusoidal components that are in qualitative agreement with the diverse experimental findings.

  7. Translational Vestibulo-Ocular Reflex and Motion Perception During Interaural Linear Acceleration: Comparison of Different Motion Paradigms

    Science.gov (United States)

    Beaton, K. H.; Holly, J. E.; Clement, G. R.; Wood, S. J.

    2011-01-01

    The neural mechanisms to resolve ambiguous tilt-translation motion have been hypothesized to be different for motion perception and eye movements. Previous studies have demonstrated differences in ocular and perceptual responses using a variety of motion paradigms, including Off-Vertical Axis Rotation (OVAR), Variable Radius Centrifugation (VRC), translation along a linear track, and tilt about an Earth-horizontal axis. While the linear acceleration across these motion paradigms is presumably equivalent, there are important differences in semicircular canal cues. The purpose of this study was to compare translation motion perception and horizontal slow phase velocity to quantify consistencies, or lack thereof, across four different motion paradigms. Twelve healthy subjects were exposed to sinusoidal interaural linear acceleration between 0.01 and 0.6 Hz at 1.7 m/s/s (equivalent to 10 tilt) using OVAR, VRC, roll tilt, and lateral translation. During each trial, subjects verbally reported the amount of perceived peak-to-peak lateral translation and indicated the direction of motion with a joystick. Binocular eye movements were recorded using video-oculography. In general, the gain of translation perception (ratio of reported linear displacement to equivalent linear stimulus displacement) increased with stimulus frequency, while the phase did not significantly vary. However, translation perception was more pronounced during both VRC and lateral translation involving actual translation, whereas perceptions were less consistent and more variable during OVAR and roll tilt which did not involve actual translation. For each motion paradigm, horizontal eye movements were negligible at low frequencies and showed phase lead relative to the linear stimulus. At higher frequencies, the gain of the eye movements increased and became more inphase with the acceleration stimulus. While these results are consistent with the hypothesis that the neural computational strategies for

  8. Efficient modeling of plasma wakefield acceleration in quasi-non-linear-regimes with the hybrid code Architect

    Science.gov (United States)

    Marocchino, A.; Massimo, F.; Rossi, A. R.; Chiadroni, E.; Ferrario, M.

    2016-09-01

    In this paper we present a hybrid approach aiming to assess feasible plasma wakefield acceleration working points with reduced computation resources. The growing interest for plasma wakefield acceleration and especially the need to control with increasing precision the quality of the accelerated bunch demands for more accurate and faster simulations. Particle in cell codes are the state of the art technique to simulate the underlying physics, however the run-time represents the major drawback. Architect is a hybrid code that treats the bunch kinetically and the background electron plasma as a fluid, initialising bunches in vacuum so to take into account for the transition from vacuum to plasma. Architect solves directly the Maxwell's equations on a Yee lattice. Such an approach allows us to drastically reduce run time without loss of generality or accuracy up to the weakly non linear regime.

  9. Efficient modeling of plasma wakefield acceleration in quasi-non-linear-regimes with the hybrid code Architect

    Energy Technology Data Exchange (ETDEWEB)

    Marocchino, A., E-mail: albz.uk@gmail.com [Dipartimento SBAI, “Sapienza” University of Rome and INFN-Roma 1, Rome (Italy); Massimo, F. [Dipartimento SBAI, “Sapienza” University of Rome and INFN-Roma 1, Rome (Italy); Rossi, A.R. [Dipartimento di Fisica, University of Milan and INFN-Milano, Milano (Italy); Chiadroni, E.; Ferrario, M. [INFN-LNF, Frascati (Italy)

    2016-09-01

    In this paper we present a hybrid approach aiming to assess feasible plasma wakefield acceleration working points with reduced computation resources. The growing interest for plasma wakefield acceleration and especially the need to control with increasing precision the quality of the accelerated bunch demands for more accurate and faster simulations. Particle in cell codes are the state of the art technique to simulate the underlying physics, however the run-time represents the major drawback. Architect is a hybrid code that treats the bunch kinetically and the background electron plasma as a fluid, initialising bunches in vacuum so to take into account for the transition from vacuum to plasma. Architect solves directly the Maxwell's equations on a Yee lattice. Such an approach allows us to drastically reduce run time without loss of generality or accuracy up to the weakly non linear regime.

  10. Dose linearity and uniformity of Siemens ONCOR impression plus linear accelerator designed for step-and-shoot intensity-modulated radiation therapy

    Directory of Open Access Journals (Sweden)

    Bhangle Janhavi

    2007-01-01

    Full Text Available For step-and-shoot type delivery of intensity-modulated radiation therapy (IMRT, beam stability characteristics during the first few monitor units need to be investigated to ensure the planned dose delivery. This paper presents the study done for Siemens ONCOR impression plus linear accelerator before commissioning it for IMRT treatment. The beam stability for 6 and 15 MV in terms of dose monitor linearity, monitor unit stability and beam uniformity is investigated in this work. Monitor unit linearity is studied using FC65G chamber for the range 1-100 MU. The dose per MU is found to be linear for small monitor units down to 1 MU for both 6 and 15 MV beams. The monitor unit linearity is also studied with portal imaging device for the range 1-20 MU for 6 MV beam. The pixel values are within ±1σ confidence level up to 2 MU; for 1 MU, the values are within ±2σ confidence level. The flatness and symmetry analysis is done for both energies in the range of 1-10 MU with Kodak diagnostic films. The flatness and symmetry are found to be within ±3% up to 2 MU for 6 MV and up to 3 MU for 15 MV.

  11. The first implementation of respiratory triggered 4DCBCT on a linear accelerator

    Science.gov (United States)

    O'Brien, Ricky T.; Cooper, Benjamin J.; Shieh, Chun-Chien; Stankovic, Uros; Keall, Paul J.; Sonke, Jan-Jakob

    2016-05-01

    signal to noise and contrast to noise ratios. RT-4DCBCT has been experimentally realised and reduced to practice on a linear accelerator with a measurable imaging dose reductions over conventional 4DCBCT and little degradation in image quality.

  12. The Variation of Surface Dose by Beam Spoiler in 10 MV Photon Beam from Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Seong Cheol; Kim, Jun Ho; Lee, Choul Soo [Dept. of Radiation Oncology, Kosin University Gospel Hospital, Busan (Korea, Republic of)

    2006-03-15

    The purpose of this study is to find a optimal beam spoiler condition on the dose distribution near the surface, when treating a squamous cell carcinoma of the head and neck and a lymphatic region with 10 MV photon beam. The use of a optimal spoiler allows delivering high dose to a superficial tumor volume, while maintaining the skin-sparing effect in the area between the surface to the depth of 0.4 cm. The lucite beam spoiler, which were a tissue equivalent, were made and placed between the surface and the photon collimators of linear accelerator. The surface-dose, the dose at the depth of 0.4 cm, and the maximum dose at the dmax were measured with a parallel-plate ionization chamber for 5 x 5 cm to 30 x 30 cm{sup 2} field sizes using lucite spoilers with different thicknesses at varying skin-to-spoiler separation (SSS). In the same condition, the dose was measured with bolus and compared with beam spoiler. The spoiler increased the surface and build-up dose and shifted the depth of maximum dose toward the surface. With a 10 MV x-ray beam and a optimal beam spoiler when treating a patient, a similar build-up dose with a 6 MV photon beam could be achieved, while maintaining a certain amount of skin spring. But it was provided higher surface dose under SSS of less than 5 cm, the spoiler thickness of more than 1.8 cm or more, and larger field size than 20 x 20 cm{sup 2} provided higher surface dose like bolus and obliterated the spin-sparing effect. the effects of the beam spoiler on beam profile was reduced with increasing depths. The lucite spoiler allowed using of a 10 MV photon beam for the radiation treatment of head and neck caner by yielding secondary scattered electron on the surface. The dose at superficial depth was increased and the depth of maximum dose was moved to near the skin surface. Spoiling the 10 MV x-ray beam resulted in treatment plans that maintained dose homogeneity without the consequence of increased skin reaction or treat volume underdose

  13. Advances in X-Band and S-Band Linear Accelerators for Security, NDT, and Other Applications

    CERN Document Server

    Mishin, Andrey V

    2005-01-01

    At AS&E High Energy Systems Division, we designed several new advanced high energy electron beam and X-ray sources. Our primary focus has always been in building the world's most portable commercial X-band accelerators. Today, our X-band systems frequently exceed performance of the similar S-band machines, while they are more portable compared to the latter. The new designs of the X-band accelerators in the most practical energy range from 1 MeV to 6 MeV have been tested delivering outstanding results. Seventy 6 MeV X-band linacs systems have been produced. The most compact linac for security is used by AS&E in a self-shielded, Shaped Energy™ cargo screening system. We pioneered using the X-band linear accelerators for CT, producing high quality images of oil pipes and wood logs. An X-band linear accelerator head on a robotic arm has been used for electron beam radiation curing of an odd-shaped graphite composite part. We developed the broad-range 4 MeV to over 10 MeV energy-regulated X-band ...

  14. Implementation of intraoperative radiotherapy in a linear accelerator Varian 21EX; Implementacao da radioterapia intraoperatoria em um acelerador linear VARIAN 21EX

    Energy Technology Data Exchange (ETDEWEB)

    Piriz, Gustavo H.; Lozano, Enrique; Banguero, Yolma; Varon, Carlos Fernando; Mancilla, Claudio S. [Instituto Nacional del Cancer, Santiago (Chile). Radioterapia; Parra, Cristian [Universidad de la Frontera, Temuco (Chile); Pacheco, P. [Universidad Nacional Mayor de San Marcos, Lima (Peru)

    2011-07-01

    The aim of this paper is to present the experience on intraoperative radiotherapy, which has as the reference center the network of radiotherapy in Chile. It is detailed the construction of a system of applicators with an easy coupling on a linear accelerator collimator. It is also detailed the cost and the measurements set up with their corresponding percentage depth dose and isodose curves. This technique was implemented in a Varian Clinac 21EX for beams with 6, 9 and 12 MeV electron energy. The coupling system provides a good dose distribution both laterally and in depth for different energies. This provides a good coverage of treatment planning volume. (author)

  15. Design and Factory Test of the E /E- Frascati Linear Accelerator for DAFNE

    Energy Technology Data Exchange (ETDEWEB)

    Anamkath, H.; Lyons, S.; Nett, D.; Treas, P.; Whitham, K.; Zante, T.; /Titan Beta, Dublin; Miller, R.; /Titan Beta, Dublin /SLAC; Boni, R.; Hsieh, H.; Sannibale, F.; Vescovi, M.; Vignola, G.; /Frascati

    2011-11-28

    The electron-positron accelerator for the DAFNE project has been built and is in test at Titan Beta in Dublin, CA. This S-Band RF linac system utilizes four 45 MW sledded klystrons and 16-3 m accelerating structures to achieve the required performance. It delivers a 4 ampere electron beam to the positron converter and accelerates the resulting positrons to 550 MeV. The converter design uses a 4.3T pulsed tapered flux compressor along with a pseudo-adiabatic tapered field to a 5 KG solenoid over the first two positron accelerating sections. Quadrupole focusing is used after 100 MeV. The system performance is given in Table 1. This paper briefly describes the design and development of the various subassemblies in this system and gives the initial factory test data.

  16. Status and perspectives of the R&D programs for the XADS linear accelerator

    CERN Document Server

    Junquera, T

    2003-01-01

    In the last years, several laboratories in Europe have developed programs to study, design and test the main components of a high intensity proton accelerator. The broad field of applications covered by this new generation of accelerators (spallation sources, transmutation, radioactive beams, neutrino beams,...)has contributed to a good synergy by developing complementary activities. These programs have succe- eded in this preliminary stage to propose accelerator designs, which fulfil the required specifications, and to launch R&D programs necessary to prove the technical feasibi- lity of the most critical components. For the XADS, the accelerator must exhibit an extremely low number of beam trips, and the new R&D programs must be focused on reliability and fault tolerance disign.

  17. Simulations of the Acceleration of Externally Injected Electrons in a Plasma Excited in the Linear Regime

    CERN Document Server

    Delerue, Nicolas; Jenzer, Stéphane; Kazamias, Sophie; Lucas, Bruno; Maynard, Gilles; Pittman, Moana

    2016-01-01

    We have investigated numerically the coupling between a 10 \\si{MeV} electron bunch of high charge (\\SI{> 100}{pc}) with a laser generated accelerating plasma wave. Our results show that a high efficiency coupling can be achieved using a \\SI{50}{TW}, \\SI{100}{\\micro \\meter} wide laser beam, yielding accelerating field above \\SI{1}{ GV/m}. We propose an experiment where these predictions could be tested.

  18. Error analysis of linear optics measurements via turn-by-turn beam position data in circular accelerators

    CERN Document Server

    Franchi, Andrea

    2016-01-01

    Many advanced techniques have been developed, tested and implemented in the last decades in almost all circular accelerators across the world to measure the linear optics. However, the greater availability and accuracy of beam diagnostics and the ever better correction of linear magnetic lattice imperfections (beta beating at 1% level and coupling at 0.1%) are reaching what seems to be the intrinsic accuracy and precision of different measurement techniques. This paper aims to highlight and quantify, when possible, the limitations of one standard method, the harmonic analysis of turn-by-turn beam position data. To this end, new analytic formulas for the evaluation of lattice parameters modified by focusing errors are derived. The unexpected conclusion of this study is that for the ESRF storage ring (and possibly for any third generation light source operating at ultra-low coupling and with similar diagnostics), measurement and correction of linear optics via orbit beam position data are to be preferred to the...

  19. DTL cavity design and beam dynamics for a TAC linear proton accelerator

    Science.gov (United States)

    Caliskan, A.; Yılmaz, M.

    2012-02-01

    A 30 mA drift tube linac (DTL) accelerator has been designed using SUPERFISH code in the energy range of 3-55 MeV in the framework of the Turkish Accelerator Center (TAC) project. Optimization criteria in cavity design are effective shunt impedance (ZTT), transit-time factor and electrical breakdown limit. In geometrical optimization we have aimed to increase the energy gain in each RF gap of the DTL cells by maximizing the effective shunt impedance (ZTT) and the transit-time factor. Beam dynamics studies of the DTL accelerator have been performed using beam dynamics simulation codes of PATH and PARMILA. The results of both codes have been compared. In the beam dynamical studies, the rms values of beam emittance have been taken into account and a low emittance growth in both x and y directions has been attempted.

  20. DTL cavity design and beam dynamics for a TAC linear proton accelerator

    Institute of Scientific and Technical Information of China (English)

    A. Caliskan; M. Yi1maz

    2012-01-01

    A 30 mA drift tube linac (DTL) accelerator has been designed using SUPERFISH code in the energy range of 3-55 MeV in the framework of the Turkish Accelerator Center (TAC) project.Optimization criteria in cavity design are effective shunt impedance (ZTT),transit-time factor and electrical breakdown limit.In geometrical optimization we have aimed to increase the energy gain in each RF gap of the DTL cells by maximizing the effective shunt impedance (ZTT) and the transit-time factor.Beam dynamics studies of the DTL accelerator have been performed using beam dynamics simulation codes of PATH and PARMILA.The results of both codes have been compared.In the beam dynamical studies,the rms values of beam emittance have been taken into account and a low emittance growth in both x and y directions has been attempted.

  1. A 7MeV S-Band 2998MHz Variable Pulse Length Linear Accelerator System

    CERN Document Server

    Hernandez, Michael; Mishin, Andrey V; Saverskiy, Aleksandr J; Skowbo, Dave; Smith, Richard

    2005-01-01

    American Science and Engineering High Energy Systems Division (AS&E HESD) has designed and commissioned a variable pulse length 7 MeV electron accelerator system. The system is capable of delivering a 7 MeV electron beam with a pulse length of 10 nS FWHM and a peak current of 1 ampere. The system can also produce electron pulses with lengths of 20, 50, 100, 200, 400 nS and 3 uS FWHM with corresponding lower peak currents. The accelerator system consists of a gridded electron gun, focusing coil, an electrostatic deflector system, Helmholtz coils, a standing wave side coupled S-band linac, a 2.6 MW peak power magnetron, an RF circulator, a fast toroid, vacuum system and a PLC/PC control system. The system has been operated at repetition rates up to 250pps. The design, simulations and experimental results from the accelerator system are presented in this paper.

  2. Accelerating clinical insights: how to use accelerator mass spectrometry to make better early development decisions.

    Science.gov (United States)

    Seymour, Mark

    2010-12-01

    This paper is an overview of the applications of the technique of Accelerator Mass Spectrometry (AMS) in the biomedical drug development field. The work described here has been carried out at Xceleron (York, UK and Germantown, MD, USA), and it aims to apply AMS to provide better information about the human pharmacokinetic/metabolic behaviour of drugs or drug candidates as early as possible. It is hoped that the use of this technique will contribute to the delivery of better, more effective drugs onto the market sooner, which will be good news for all concerned.

  3. Non-linear Ion-Wake Excitation by Plasma Electron Wakefields of an Electron or Positron Beam for Positron Acceleration

    Science.gov (United States)

    Katsouleas, Thomas; Sahai, Aakash

    2015-11-01

    The excitation of a non-linear ion-wake by a train of non-linear electron wake of an electron and a positron beam is modeled and its use for positron acceleration is explored. The ion-wake is shown to be a driven non-linear ion-acoustic wave in the form of a cylindrical ion-soliton similar to the solution of the cKdV equation. The phases of the oscillating radial electric fields of the slowly-propagating electron wake are asymmetric in time and excite time-averaged inertial ion motion radially. The radial field of the electron compression region sucks-in the ions and the field of space-charge region of the wake expels them, driving a cylindrical ion-soliton structure with on-axis and bubble-edge density-spikes. Once formed, the channel-edge density-spike is driven radially outwards by the thermal pressure of the thermalized wake energy. Its channel-like structure due to the flat-residue left behind by the propagating ion-soliton, is independent of the energy-source driving the non-linear electron wake. We explore the use of the partially-filled channel formed by the cylindrical ion-soliton for a novel regime of positron acceleration. PIC simulations are used to study the ion-wake soliton structure, its driven propagation and its use for positron acceleration (arXiv:1504.03735). Work supported by the US Department of Energy under DE-SC0010012 and the National Science Foundation under NSF-PHY-0936278.

  4. Simulation of the relativistic electron dynamics and acceleration in a linearly-chirped laser pulse

    CERN Document Server

    Jisrawi, Najeh M; Salamin, Yousef I

    2014-01-01

    Theoretical investigations are presented, and their results are discussed, of the laser acceleration of a single electron by a chirped pulse. Fields of the pulse are modeled by simple plane-wave oscillations and a $\\cos^2$ envelope. The dynamics emerge from analytic and numerical solutions to the relativistic Lorentz-Newton equations of motion of the electron in the fields of the pulse. All simulations have been carried out by independent Mathematica and Python codes, with identical results. Configurations of acceleration from a position of rest as well as from injection, axially and sideways, at initial relativistic speeds are studied.

  5. TU-C-BRE-02: A Novel, Highly Efficient and Automated Quality Assurance Tool for Modern Linear Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Goddu, S; Sun, B; Yaddanapudi, S; Kamal, G; Mutic, S [Washington University, St. Louis, MO (United States); Baltes, C; Rose, S [Varian Medical Systems iLab GmbH, Baden, Dattwil (Switzerland); Stinson, K [Varian Medical Systems, Palo Alto, CA (United States)

    2014-06-15

    Purpose: Quality assurance (QA) of complex linear accelerators is critical and highly time consuming. Varian’s Machine Performance Check (MPC) uses IsoCal phantom to test geometric and dosimetric aspects of the TrueBeam systems in <5min. In this study we independently tested the accuracy and robustness of the MPC tools. Methods: MPC is automated for simultaneous image-acquisition, using kV-and-MV onboard-imagers (EPIDs), while delivering kV-and-MV beams in a set routine of varying gantry, collimator and couch angles. MPC software-tools analyze the images to test: i) beam-output and uniformity, ii) positional accuracy of isocenter, EPIDs, collimating jaws (CJs), MLC leaves and couch and iii) rotational accuracy of gantry, collimator and couch. 6MV-beam dose-output and uniformity were tested using ionization-chamber (IC) and ICarray. Winston-Lutz-Tests (WLT) were performed to measure isocenter-offsets caused by gantry, collimator and couch rotations. Positional accuracy of EPIDs was evaluated using radio-opaque markers of the IsoCal phantom. Furthermore, to test the robustness of the MPC tools we purposefully miscalibrated a non-clinical TrueBeam by introducing errors in beam-output, energy, symmetry, gantry angle, couch translations, CJs and MLC leaves positions. Results: 6MV-output and uniformity were within ±0.6% for most measurements with a maximum deviation of ±1.0%. Average isocenter-offset caused by gantry and collimator rotations was 0.316±0.011mm agreeing with IsoLock (0.274mm) and WLT (0.41mm). Average rotation-induced couch-shift from MPC was 0.378±0.032mm agreeing with WLT (0.35mm). MV-and-kV imager-offsets measured by MPC were within ±0.15mm. MPC predicted all machine miscalibrations within acceptable clinical tolerance. MPC detected the output miscalibrations within ±0.61% while the MLC and couch positions were within ±0.06mm and ±0.14mm, respectively. Gantry angle miscalibrations were detected within ±0.1°. Conclusions: MPC is a useful tool

  6. 直线加速器粒子模拟可视化%Particle Simulation Visualization for the Linear Accelerator

    Institute of Scientific and Technical Information of China (English)

    田东; 张智磊; 单桂华; 杨磊; 齐记; 张阔

    2013-01-01

    直线加速器被广泛应用于国防、能源、医疗等多个领域,加速器粒子模拟可视化是研究大规模高能粒子运动规律的重要方法。本文利用OpenGL和GLSL混合编程,给出了一套针对直线加速器粒子的科学模拟可视化与可视分析的方案,可清晰展示粒子在加速过程中的整体状态和运动趋势,体现出高速粒子的分类属性及其变化规律,为直线加速器的诊断分析提供了有效的工具。%Programming mixed with OpenGL and GLSL, we proposed a set of programs of scientiifc visualization and visual analysis for linear accelerator particles, which not only clearly present the particle acceleration process in overall status and exercise trends, but also relfect the high-speed particle properties and their classiifcation attributes, and it provided useful tools for linear accelerator diagnostic analysis.

  7. A study of the energy enhancement of electron in radio frequency (RF) linear accelerator of iris loaded waveguards

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Huy-Bich [Nong Lam Univ., Hochiminh City (Viet Nam). Faculty of Engineering and Technology; National Univ., Hochiminh City (Viet Nam). National Key Lab. of Digital Control and System Engineering (DCSELAB); Trinh, Hoa-Lang [Natural Science Univ., Hochiminh City (Viet Nam). Faculty of Physics - Physical Engineering; Nong Lam Univ., Hochiminh City (Viet Nam). Faculty of Engineering and Technology; Chau, Van-Tao; Nguyen, Van-Tuong [Natural Science Univ., Hochiminh City (Viet Nam). Faculty of Physics - Physical Engineering

    2014-06-15

    In this paper, the Hamiltonian theory of particle motion has been applied for developing the motion equations of electrons in linear accelerator of Iris-loaded waveguides. Using J. C. Slater assumption for determining electric field in Oz direction, the energy increase of electron in the guide wave pipe following the linacs resonance cavity with circulated electromagnetic distribution and repeat-cycle of given number of resonance cavities has been developed. The energy gain of electron following the electron way in Oz axle direction of the accelerator with the different injection phase and phase shift of RF has been obtained. The results indicate that the energy increase of electron depends on the injection phase of RF and cell-to-cell phase shift.

  8. Study of the electronics architecture for the mechanical stabilisation of the quadrupoles of the CLIC linear accelerator

    CERN Document Server

    Artoos, K; Fernandez Carmona, P; Guinchard, M; Hauviller, C; Janssens, S; Kuzmin, A; Slaathaug, A

    2010-01-01

    To reach a sufficient luminosity, the transverse beam sizes and emittances in future linear particle accelerators should be reduced to the nanometer level. Mechanical stabilisation of the quadrupole magnets is of the utmost importance for this. The piezo actuators used for this purpose can also be used to make fast incremental orientation adjustments with a nanometer resolution. The main requirements for the CLIC stabilisation electronics is a robust, low noise, low delay, high accuracy and resolution, low band and radiation resistant feedback control loop. Due to the high number of controllers (about 4000) a cost optimization should also be made. Different architectures are evaluated for a magnet stabilisation prototype, including the sensors type and configuration, partition between software and hardware for control algorithms, and optimization of the ADC/DAC converters. The controllers will be distributed along the 50 km long accelerator and a communication bus should allow external control. Furthermore, o...

  9. Do technological advances in linear accelerators improve dosimetric outcomes in stereotaxy? A head-on comparison of seven linear accelerators using volumetric modulated arc therapy-based stereotactic planning

    Directory of Open Access Journals (Sweden)

    B Sarkar

    2016-01-01

    Full Text Available Introduction: Linear accelerator (Linac based stereotactic radiosurgery (SRS and stereotactic radiotherapy (SRT using volumetric modulated arc therapy (VMAT has been used for treating small intracranial lesions. Recent development in the Linacs such as inbuilt micro multileaf collimator (MLC and flattening filter free (FFF beam are intended to provide a better dose conformity and faster delivery when using VMAT technique. This study was aimed to compare the dosimetric outcomes and monitor units (MUs of the stereotactic treatment plans for different commercially available MLC models and beam profiles. Materials and Methods: Ten patients having 12 planning target volume (PTV/gross target volume's (GTVs who received the SRS/SRT treatment in our clinic using Axesse Linac (considered reference arm gold standard were considered for this study. The test arms comprised of plans using Elekta Agility with FFF, Elekta Agility with the plane beam, Elekta APEX, Varian Millennium 120, Varian Millennium 120HD, and Elekta Synergy in Monaco treatment planning system. Planning constraints and calculation grid spacing were not altered in the test plans. To objectively evaluate the efficacy of MLC-beam model, the resultant dosimetric outcomes were subtracted from the reference arm parameters. Results: V95%, V100%, V105%, D1%, maximum dose, and mean dose of PTV/GTV showed a maximum inter MLC - beam model variation of 1.5% and 2% for PTV and GTV, respectively. Average PTV conformity index and heterogeneity index shows a variation in the range 0.56–0.63 and 1.08–1.11, respectively. Mean dose difference (excluding Axesse for all organs varied between 1.1 cGy and 74.8 cGy (mean dose = 6.1 cGy standard deviation [SD] = 26.9 cGy and 1.7 cGy–194.5 cGy (mean dose 16.1 cGy SD = 57.2 cGy for single and multiple fraction, respectively. Conclusion: The dosimetry of VMAT-based SRS/SRT treatment plan had minimal dependence on MLC and beam model variations. All tested MLC

  10. Clinical aspects and potential clinical applications of laser accelerated proton beams

    Science.gov (United States)

    Spatola, C.; Privitera, G.

    2013-07-01

    Proton beam radiation therapy (PBRT), as well as the other forms of hadrontherapy, is in use in the treatment of neoplastic diseases, to realize a high selective irradiation with maximum sparing of surrounding organs. The main characteristic of such a particles is to have an increased radiobiological effectiveness compared to conventional photons (about 10% more) and the advantage to deposit the energy in a defined space through the tissues (Bragg peak phenomenon). The goal of ELIMED Project is the realization of a laser accelerated proton beam line to prove its potential use for clinical application in the field of hadrontherapy. To date, there are several potential clinical applications of PBRT, some of which have become the treatment of choice for a specific tumour, for others it is under investigation as a therapeutic alternative to conventional X-ray radiotherapy, to increase the dose to the tumour and reduce the side effects. For almost half of cancers, an increased local tumour control is the mainstay for increased cancer curability.

  11. Feasibility of an XUV FEL Oscillator Driven by a SCRF Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H.; Freund, H. P.; Reinsch, M.

    2014-01-01

    The Advanced Superconducting Test Accelerator (ASTA) facility is currently under construction at Fermi National Accelerator Laboratory. Using a1-ms-long macropulse composed of up to 3000 micropulses, and with beam energies projected from 45 to 800 MeV, the possibility for an extreme ultraviolet (XUV) free-electron laser oscillator (FELO) with the higher energy is evaluated. We have used both GINGER with an oscillator module and the MEDUSA/OPC code to assess FELO saturation prospects at 120 nm, 40 nm, and 13.4 nm. The results support saturation at all of these wavelengths which are also shorter than the demonstrated shortest wavelength record of 176 nm from a storage-ring-based FELO. This indicates linac-driven FELOs can be extended into this XUV wavelength regime previously only reached with single-pass FEL configurations.

  12. VARIAN 23EX直线加速器故障分析%Maintenance for Varian 23EX linear accelerator

    Institute of Scientific and Technical Information of China (English)

    花威; 李军; 谭飞; 陈雪梅

    2013-01-01

    This paper describes four malfunctions of Varian 23EX linear accelerator, puts forward the troubleshooting messure. Four malfunctions are CARR interlock, HWFA interlock of treatment bed, HWFA interlock of collimator and tungsten gate fault.%分析VARIAN 23EX直线加速器CARR联锁、治疗床HWFA联锁、机头HWFA联锁和钨门不到位的4例故障,通过对故障实例的分析及介绍故障排除的方法,为同行提供参考.

  13. Design of a 5-MA 100-ns linear-transformer-driver accelerator for wire array Z-pinch experiments

    Science.gov (United States)

    Zhou, Lin; Li, Zhenghong; Wang, Zhen; Liang, Chuan; Li, Mingjia; Qi, Jianmin; Chu, Yanyun

    2016-03-01

    The linear-transformer-driver (LTD) is a recently developed pulsed-power technology that shows great promise for a number of applications. These include a Z -pinch-driven fission-fusion-hybrid reactor that is being developed by the Chinese Academy of Engineering Physics. In support of the reactor development effort, we are planning to build an LTD-based accelerator that is optimized for driving wire-array Z -pinch loads. The accelerator comprises six modules in parallel, each of which has eight series 0.8-MA LTD cavities in a voltage-adder configuration. Vacuum transmission lines are used from the interior of the adder to the central vacuum chamber where the load is placed. Thus the traditional stack-flashover problem is eliminated. The machine is 3.2 m tall and 12 m in outer diameter including supports. A prototype cavity was built and tested for more than 6000 shots intermittently at a repetition rate of 0.1 Hz. A novel trigger, in which only one input trigger pulse is needed by utilizing an internal trigger brick, was developed and successfully verified in these shots. A full circuit modeling was conducted for the accelerator. The simulation result shows that a current pulse rising to 5.2 MA in 91 ns (10%-90%) can be delivered to the wire-array load, which is 1.5 cm in height, 1.2 cm in initial radius, and 1 mg in mass. The maximum implosion velocity of the load is 32 cm /μ s when compressed to 0.1 of the initial radius. The maximum kinetic energy is 78 kJ, which is 11.7% of the electric energy stored in the capacitors. This accelerator is supposed to enable a radiation energy efficiency of 20%-30%, providing a high efficient facility for research on the fast Z pinch and technologies for repetition-rate-operated accelerators.

  14. Simulation and characterization of the RF system and global stability analysis at the REGAE linear electron accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Mayet, Frank

    2012-12-15

    LAOLA (LAboratory for Laser- and beam-driven plasma Acceleration), is a collaboration between groups from DESY and the University of Hamburg. Its mission is to complement basic research in the relatively new field of plasma wakefield acceleration (PWA) by an explicit combination with DESY's conventional, modern accelerators. The linear electron accelerator REGAE is designed to produce sub 10 fs low charge electron bunches with ultra-low emittance at a repetition rate of 50 Hz. The planned experiments include femtosecond electron diffraction (R.J. Dwayne Miller), as well as the probing of laser induced plasma wakefields with well characterized bunches (LAOLA). They all require high bunch time of flight stability down to 10 fs. The REGAE machine consists of two RF cavities, both fed by a single klystron. While the first one - the gun cavity - is used for acceleration of the electrons, the second one - the buncher cavity - can be used to reduce the electron bunch length. This scheme only works for a specific RF phase relation between the two cavities. This thesis is split into two parts. In the first one the implications of the unique two cavity design on day-to-day machine operation are analyzed. To this end an analytical model of the RF system is developed, which is necessary for understanding how to individually adjust the cavity phases. In the second part the influence of the setup on time of flight stability is discussed with an emphasis on phase jitter compensation. RF phase stability measurements reveal that the current machine setup allows for a time of flight stability down to 50 fs right after the gun.

  15. Study of quality assurance regulations for linear accelerators in Korea: A comparison study between the current status in Korea and the international guidelines

    CERN Document Server

    Lee, Hyunho; Jo, Yunhui; Yoon, Myonggeun

    2015-01-01

    Quality assurance (QA) for medical linear accelerators is indispensable for appropriate cancer treatment. Some international organizations and western advanced countries provide QA guidelines for linear accelerators. Currently, QA regulations for linear accelerators in Korean hospitals specify a system in which each hospital stipulates its independent hospital-based protocols for QA procedures (HP_QAPs) and conducts QA based on these HP_QAPs while regulatory authorities verify whether items under these HP_QAPs have been performed. However, because this regulatory method cannot guarantee the quality of universal treatment, and QA items with tolerance criteria are different in many hospitals, the presentation of standardized QA items and tolerance criteria is essential. In this study, QA items in HP_QAPs from various hospitals and those presented by international organizations. Concordance rates between QA items for linear accelerators that were presented by the aforementioned organizations and those currently ...

  16. Non-Linear Transmission Line (NLTL) Microwave Source Lecture Notes the United States Particle Accelerator School

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Steven J. [Los Alamos National Laboratory; Carlsten, Bruce E. [Los Alamos National Laboratory

    2012-06-26

    We will quickly go through the history of the non-linear transmission lines (NLTLs). We will describe how they work, how they are modeled and how they are designed. Note that the field of high power, NLTL microwave sources is still under development, so this is just a snap shot of their current state. Topics discussed are: (1) Introduction to solitons and the KdV equation; (2) The lumped element non-linear transmission line; (3) Solution of the KdV equation; (4) Non-linear transmission lines at microwave frequencies; (5) Numerical methods for NLTL analysis; (6) Unipolar versus bipolar input; (7) High power NLTL pioneers; (8) Resistive versus reactive load; (9) Non-lineaer dielectrics; and (10) Effect of losses.

  17. Dosimetric study of small circular X-rays fields used in radiosurgery with linear accelerator of 6 MV; Estudo dosimetrico de campos circulares pequenos de raios-X utilizados em radiocirurgia com um acelerador linear de 6 MV

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, Jose Carlos da [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil). Servico de Radioterapia; Segreto, Roberto Araujo; Segreto, Helena R. Comodo [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. de Medicina. Setor de Radioterapia]. E-mail: josecarlos@einstein.br

    2003-07-01

    Three dosimetric systems were compared regarding dosimetry of small circular x ray fields used in radiosurgery. The dosimetric parameters for circular cones, with diameters ranging from 7 to 30 mm, were acquired using a 6 MV Clinac 600 C linear accelerator. For the measurement of tissue maximum ratios, total scatter factor and radiation field profile, Kodak X-Omat type V radiographic films, and ionization chamber of 0.1 cm{sup 3} and a plane parallel ionization chamber type Markus were used. The plane parallel ionization chamber showed satisfactory results for measurement of tissue maximum ratios and total scatter only for cone sizes larger than 11 mm in diameter. Beam profile showed better spatial resolution when films ere used. The main physical parameters of small circular fields used in radiosurgery can be obtained by combining the dosimetry results of radiation therapy equipment used in current clinical practice. (author)

  18. Accelerated prompt gamma estimation for clinical proton therapy simulations

    Science.gov (United States)

    Huisman, Brent F. B.; Létang, J. M.; Testa, É.; Sarrut, D.

    2016-11-01

    There is interest in the particle therapy community in using prompt gammas (PGs), a natural byproduct of particle treatment, for range verification and eventually dose control. However, PG production is a rare process and therefore estimation of PGs exiting a patient during a proton treatment plan executed by a Monte Carlo (MC) simulation converges slowly. Recently, different approaches to accelerating the estimation of PG yield have been presented. Sterpin et al (2015 Phys. Med. Biol. 60 4915-46) described a fast analytic method, which is still sensitive to heterogeneities. El Kanawati et al (2015 Phys. Med. Biol. 60 8067-86) described a variance reduction method (pgTLE) that accelerates the PG estimation by precomputing PG production probabilities as a function of energy and target materials, but has as a drawback that the proposed method is limited to analytical phantoms. We present a two-stage variance reduction method, named voxelized pgTLE (vpgTLE), that extends pgTLE to voxelized volumes. As a preliminary step, PG production probabilities are precomputed once and stored in a database. In stage 1, we simulate the interactions between the treatment plan and the patient CT with low statistic MC to obtain the spatial and spectral distribution of the PGs. As primary particles are propagated throughout the patient CT, the PG yields are computed in each voxel from the initial database, as a function of the current energy of the primary, the material in the voxel and the step length. The result is a voxelized image of PG yield, normalized to a single primary. The second stage uses this intermediate PG image as a source to generate and propagate the number of PGs throughout the rest of the scene geometry, e.g. into a detection device, corresponding to the number of primaries desired. We achieved a gain of around 103 for both a geometrical heterogeneous phantom and a complete patient CT treatment plan with respect to analog MC, at a convergence level of 2% relative

  19. Experimental study of new laser-based alignment system at the KEK B-factory injector linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Suwada, T.; Satoh, M.; Kadokura, E. [Accelerator Laboratory, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan)

    2010-12-15

    A new laser-based alignment system for the precise alignment of accelerator components along an ideal straight line at the KEK B-factory injector linear accelerator (linac) is under development. This system is strongly required in the next generation of B-factories for the stable acceleration of high-brightness electron and positron beams with high bunch charges and also for maintaining the stability of injection beams with high quality. A new laser optics for the generation of a so-called Airy beam has been developed for the laser-based alignment system. The laser propagation characteristics both in vacuum and at atmospheric pressure have been systematically investigated in an 82-m-long straight section of the injector linac. The laser-based alignment measurements based on the new laser optics have been carried out with a measurement resolution of {+-}0.1 mm level by using an existing laser detection electronics. The horizontal and vertical displacements from a reference laser line measured using this system are in good agreement with those measured using a standard telescope-based optical alignment technique. In this report, we describe the experimental study in detail along with the basic designs and the recent developments in the new laser-based alignment system.

  20. 3D simulations of supernova remnants evolution including non-linear particle acceleration

    CERN Document Server

    Ferrand, Gilles; Ballet, Jean; Teyssier, Romain; Fraschetti, Federico

    2009-01-01

    If a sizeable fraction of the energy of supernova remnant shocks is channeled into energetic particles (commonly identified with Galactic cosmic rays), then the morphological evolution of the remnants must be distinctly modified. Evidence of such modifications has been recently obtained with the Chandra and XMM-Newton X-ray satellites. To investigate these effects, we coupled a semi-analytical kinetic model of shock acceleration with a 3D hydrodynamic code (by means of an effective adiabatic index). This enables us to study the time-dependent compression of the region between the forward and reverse shocks due to the back reaction of accelerated particles, concomitantly with the development of the Rayleigh-Taylor hydrodynamic instability at the contact discontinuity. Density profiles depend critically on the injection level eta of particles: for eta up to about 10^-4 modifications are weak and progressive, for eta of the order of 10^-3 modifications are strong and immediate. Nevertheless, the extension of the...

  1. Stability of a mobile electron linear accelerator system for intraoperative radiation therapy.

    Science.gov (United States)

    Beddar, A Sam

    2005-10-01

    The flexibility of mobile electron accelerators, which are designed to be transported to an operating room and plugged into a normal 3-phase outlet, make them ideal for use in intraoperative radiation therapy. However, their transportability may cause trepidation among potential users, who may question the stability of such an accelerator over a period of use. In order to address this issue, we have studied the short-term stability of the Mobetron system over 20 daily quality assurance trials. Variations in output generally varied within +/-2% for the four energies produced by the unit (4, 6, 9, and 12 MeV) and changes in energy produced an equivalent shift of less than 1 mm on the depth-dose curve. Hours of inactivity, with the Mobetron powered on for use either throughout the day or overnight, led to variations in output of about 1%. Finally, we have tested the long-term stability of the absolute dose output of the Mobetron, which showed a change of about 1% per year.

  2. Final Commissioning of the Superconducting Heavy Ion Linear Accelerator at IUAC, Delhi

    Science.gov (United States)

    Datta, Tripti Sekhar; Choudhury, Anup; Chacko, Jacob; Kar, Soumen; Antony, Joby; Babu, Suresh; Kumar, Manoj; Mathuria, D. S.; Sahu, Santosh; Kanjilal, Dinakar

    The superconducting linac as a booster of the 15UD Pelletron accelerator was partly commissioned with one linac module housing eight quarter wave bulk niobium cavities along with the superbuncher and rebuncher cryomodules. Subsequently two more linac cryomodules were added to have in total 24 cavities for acceleration. In addition, a new Linde helium refrigerator of capacity 750 W @ 4.2 K was installed in parallel to the earlier CCI refrigerator. The new refrigerator was integrated with the earlier cryogenics network system through a specially designed liquid helium distribution line without any valve box. The cooling philosophy with this new system is modified to have a faster cool down rate in the critical zone (150 - 70 K) to avoid Q disease. The helium gas pressure fluctuation in the cavities is reduced significantly to have stable RF locking. The full linac is being operated and beams with higher energy are being delivered to the users. The present paper will highlight the performance of the new cryogenic system with respect to cool down rate, and helium pressure fluctuation.

  3. Be aware of neutrons outside short mazes from 10-MV linear accelerators X-rays in radiotherapy facilities.

    Science.gov (United States)

    Brockstedt, S; Holstein, H; Jakobsson, L; Tomaszewicz, A; Knöös, T

    2015-07-01

    During the radiation survey of a reinstalled 10-MV linear accelerator in an old radiation treatment facility, high dose rates of neutrons were observed. The area outside the maze entrance is used as a waiting room where patients, their relatives and staff other than those involved in the actual treatment can freely pass. High fluence rates of neutrons would cause an unnecessary high effective dose to the staff working in the vicinity of such a system, and it can be several orders higher than the doses received due to X-rays at the same location. However, the common knowledge appears to have been that the effect of neutrons at 10-MV X-ray linear accelerator facilities is negligible and shielding calculations models seldom mention neutrons for this operating energy level. Although data are scarce, reports regarding this phenomenon are now emerging. For the future, it is advocated that contributions from neutrons are considered already during the planning stage of new or modified facilities aimed for 10 MV and that estimated dose levels are verified.

  4. Spatial dependence and origin of the ambient dose due to neutron activation processes in linear accelerators; Dependencia espacial y origen de la dosis ambiental debeda a procesos de activacion neutronica en aceleradores lineales

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Egea, E.; Sanchez Carrascal, M.; Torres Pozas, S.; Monja Ray, P. de la; Perez Molina, J. L.; Madan Rodriguez, C.; Luque Japon, L.; Morera Molina, A.; Hernandez Perez, A.; Barquero Bravo, Y.; Morengo Pedagna, I.; Oliva Gordillo, M. C.; Martin Olivar, R.

    2011-07-01

    In order to try to determine the high dose in the bunker of a Linear Accelerator clinical use trying to measure the spatial dependence of the same from the isocenter to gateway to the board cheeking to establish the origin of it. This dose measurements performed with an ionization chamber at different locations inside the bunker after an irradiation of 400 Monitor Units verifying the dose rate per minute for an hour, and accumulating the dose received during that period of time.

  5. Many-core graph analytics using accelerated sparse linear algebra routines

    Science.gov (United States)

    Kozacik, Stephen; Paolini, Aaron L.; Fox, Paul; Kelmelis, Eric

    2016-05-01

    Graph analytics is a key component in identifying emerging trends and threats in many real-world applications. Largescale graph analytics frameworks provide a convenient and highly-scalable platform for developing algorithms to analyze large datasets. Although conceptually scalable, these techniques exhibit poor performance on modern computational hardware. Another model of graph computation has emerged that promises improved performance and scalability by using abstract linear algebra operations as the basis for graph analysis as laid out by the GraphBLAS standard. By using sparse linear algebra as the basis, existing highly efficient algorithms can be adapted to perform computations on the graph. This approach, however, is often less intuitive to graph analytics experts, who are accustomed to vertex-centric APIs such as Giraph, GraphX, and Tinkerpop. We are developing an implementation of the high-level operations supported by these APIs in terms of linear algebra operations. This implementation is be backed by many-core implementations of the fundamental GraphBLAS operations required, and offers the advantages of both the intuitive programming model of a vertex-centric API and the performance of a sparse linear algebra implementation. This technology can reduce the number of nodes required, as well as the run-time for a graph analysis problem, enabling customers to perform more complex analysis with less hardware at lower cost. All of this can be accomplished without the requirement for the customer to make any changes to their analytics code, thanks to the compatibility with existing graph APIs.

  6. Radio frequency pulse compression experiments at SLAC (Stanford Linear Accelerator Center)

    Energy Technology Data Exchange (ETDEWEB)

    Farkas, Z.D.; Lavine, T.L.; Menegat, A.; Miller, R.H.; Nantista, C.; Spalek, G.; Wilson, P.B.

    1991-01-01

    Proposed future positron-electron linear colliders would be capable of investigating fundamental processes of interest in the 0.5--5 TeV beam-energy range. At the SLAC Linear Collider (SLC) gradient of about 20 MV/m this would imply prohibitive lengths of about 50--250 kilometers per linac. We can reduce the length by increasing the gradient but this implies high peak power, on the order of 400-- to 1000-MW at X-Band. One possible way to generate high peak power is to generate a relatively long pulse at a relatively low power and compress it into a short pulse with higher peak power. It is possible to compress before DC to RF conversion, as is done using magnetic switching for induction linacs, or after DC to RF conversion, as is done for the SLC. Using RF pulse compression it is possible to boost the 50-- to 100-MW output that has already been obtained from high-power X-Band klystrons the levels required by the linear colliders. In this note only radio frequency pulse compression (RFPC) is considered.

  7. 3-D Model of Broadband Emission from Supernova Remnants Undergoing Non-linear Diffusive Shock Acceleration

    CERN Document Server

    Lee, Shiu-Hang; Ellison, Donald C

    2008-01-01

    We present a 3-dimensional model of supernova remnants (SNRs) where the hydrodynamical evolution of the remnant is modeled consistently with nonlinear diffusive shock acceleration occuring at the outer blast wave. The model includes particle escape and diffusion outside of the forward shock, and particle interactions with arbitrary distributions of external ambient material, such as molecular clouds. We include synchrotron emission and cooling, bremsstrahlung radiation, neutral pion production, inverse-Compton (IC), and Coulomb energy-loss. Boardband spectra have been calculated for typical parameters including dense regions of gas external to a 1000 year old SNR. In this paper, we describe the details of our model but do not attempt a detailed fit to any specific remnant. We also do not include magnetic field amplification (MFA), even though this effect may be important in some young remnants. In this first presentation of the model we don't attempt a detailed fit to any specific remnant. Our aim is to devel...

  8. Non-linear Cosmic Ray propagation close to the acceleration site

    CERN Document Server

    Nava, Lara; Marcowith, Alexandre; Morlino, Giovanni; Ptuskin, Vladimir

    2015-01-01

    Recent advances on gamma-ray observations from SuperNova Remnants and Molecular Clouds offer the possibility to study in detail the properties of the propagation of escaping Cosmic Rays (CR). However, a complete theory for CR transport outside the acceleration site has not been developed yet. Two physical processes are thought to be relevant to regulate the transport: the growth of waves caused by streaming instability, and possible wave damping mechanisms that reduce the growth of the turbulence. Only a few attempts have been made so far to incorporate these mechanisms in the theory of CR diffusion. In this work we present recent advances in this subject. In particular, we show results obtained by solving the coupled equations for the diffusion of CRs and the evolution of Alfven waves. We discuss the importance of streaming instabilities and wave damping in different ISM phases.

  9. Intracranial stereotactic radiosurgery with an adapted linear accelerator vs. robotic radiosurgery. Comparison of dosimetric treatment plan quality

    Energy Technology Data Exchange (ETDEWEB)

    Treuer, Harald; Hoevels, Moritz; Luyken, Klaus; Visser-Vandewalle, Veerle; Wirths, Jochen; Ruge, Maximilian [University Hospital Cologne, Department of Stereotaxy and Functional Neurosurgery, Cologne (Germany); Kocher, Martin [University Hospital Cologne, Department of Radiotherapy, Cologne (Germany)

    2014-11-22

    Stereotactic radiosurgery with an adapted linear accelerator (linac-SRS) is an established therapy option for brain metastases, benign brain tumors, and arteriovenous malformations. We intended to investigate whether the dosimetric quality of treatment plans achieved with a CyberKnife (CK) is at least equivalent to that for linac-SRS with circular or micromultileaf collimators (microMLC). A random sample of 16 patients with 23 target volumes, previously treated with linac-SRS, was replanned with CK. Planning constraints were identical dose prescription and clinical applicability. In all cases uniform optimization scripts and inverse planning objectives were used. Plans were compared with respect to coverage, minimal dose within target volume, conformity index, and volume of brain tissue irradiated with ≥ 10 Gy. Generating the CK plan was unproblematic with simple optimization scripts in all cases. With the CK plans, coverage, minimal target volume dosage, and conformity index were significantly better, while no significant improvement could be shown regarding the 10 Gy volume. Multiobjective comparison for the irradiated target volumes was superior in the CK plan in 20 out of 23 cases and equivalent in 3 out of 23 cases. Multiobjective comparison for the treated patients was superior in the CK plan in all 16 cases. The results clearly demonstrate the superiority of the irradiation plan for CK compared to classical linac-SRS with circular collimators and microMLC. In particular, the average minimal target volume dose per patient, increased by 1.9 Gy, and at the same time a 14 % better conformation index seems to be an improvement with clinical relevance. (orig.) [German] Stereotaktische Radiochirurgie mit einem adaptierten Linearbeschleuniger (Linac-SRS) ist eine erfolgreiche und etablierte Therapieoption fuer Hirnmetastasen, benigne Hirntumoren und arteriovenoese Malformationen. Ziel war es, zu untersuchen, ob die mit einem CyberKnife (CK) erreichbare

  10. The Quality Control of Intensity Modulated Radiation Therapy (IMRT for ONCOR Siemens Linear Accelerators Using Film Dosimetry

    Directory of Open Access Journals (Sweden)

    Keyvan Jabbari

    2012-03-01

    Full Text Available Introduction Intensity Modulated Radiation Therapy (IMRT has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various steps of planning and quality control of Siemens linear accelerators for IMRT, using film dosimetry. This article in addition to review of the techniques, discusses the details of experiments and possible sources of errors which are not mentioned in the protocols and other references. Materials and Methods This project was carried out in Isfahan Milad hospital which has two Siemens ONCOR linear accelerators. Both accelerators are equipped with Multi-Leaf Collimators (MLC which enables us to perform IMRT delivery in the step-and-shoot method. The quality control consists of various experiments related to the sections of radiation therapy. In these experiments, the accuracy of some components such as treatment planning system, imaging device (CT, MLC, control system of accelerator, and stability of the output are evaluated. The dose verification is performed using film dosimetry method. The films were KODAK-EDR2, which were calibrated before the experiments. One of the important steps is the comparison of the calculated dose with planning system and the measured dose in experiments. Results The results of the experiments in various steps have been acceptable according to the standard protocols. The calibration of MLC and evaluation of the leakage through the leaves of MLC was performed by using the film dosimetry and visual check. In comparison with calculated and measured dose, more that 80% of the points have to be in agreement within 3% of the value. In our experiments, between 85 and 90% of the points had such an agreement with IMRT delivery. Conclusion

  11. Design and optimization of Compact Linear Collider main linac accelerating structure

    Science.gov (United States)

    Zha, Hao; Grudiev, Alexej

    2016-11-01

    The Compact Linear Collider (CLIC) main linac uses waveguide damped structure as its baseline design. The current baseline structure design written in the CLIC Conceptual Design Report is named "CLIC-G." Recent activities on the CLIC-G design including high power tests on structure prototypes and the study of machining cost assessment had raised the need of reoptimizing the structure design to minimize the machining cost and the pulse surface temperature rise. This work presents optimization of the structure geometry, high-order-mode (HOM) damping loads and the design of a HOM-free power splitter for the input coupler. Compared to the current baseline design CLIC-G, the new structure design reduced the pulse surface temperature rise, input power and manufacturing cost and achieves better suppression to the long range transverse wakefield. Cell disks and damping loads for the new structure design are also more compact than those of the CLIC-G design.

  12. Hosing Instability of the Drive Electron Beam in the E157 Plasma-Wakefield Acceleration Experiment at the Stanford Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Blue, Brent Edward; /SLAC /UCLA

    2005-10-10

    In the plasma-wakefield experiment at SLAC, known as E157, an ultra-relativistic electron beam is used to both excite and witness a plasma wave for advanced accelerator applications. If the beam is tilted, then it will undergo transverse oscillations inside of the plasma. These oscillations can grow exponentially via an instability know as the electron hose instability. The linear theory of electron-hose instability in a uniform ion column predicts that for the parameters of the E157 experiment (beam charge, bunch length, and plasma density) a growth of the centroid offset should occur. Analysis of the E157 data has provided four critical results. The first was that the incoming beam did have a tilt. The tilt was much smaller than the radius and was measured to be 5.3 {micro}m/{delta}{sub z} at the entrance of the plasma (IP1.) The second was the beam centroid oscillates in the ion channel at half the frequency of the beam radius (betatron beam oscillations), and these oscillations can be predicted by the envelope equation. Third, up to the maximum operating plasma density of E157 ({approx}2 x 10{sup 14} cm{sup -3}), no growth of the centroid offset was measured. Finally, time-resolved data of the beam shows that up to this density, no significant growth of the tail of the beam (up to 8ps from the centroid) occurred even though the beam had an initial tilt.

  13. Development of Low Level RF Control Systems for Superconducting Heavy Ion Linear Accelerators, Electron Synchrotrons and Storage Rings

    CERN Document Server

    Aminov, Bachtior; Kolesov, Sergej; Pekeler, Michael; Piel, Christian; Piel, Helmut

    2005-01-01

    Since 2001 ACCEL Instruments is supplying low level RF control systems together with turn key cavity systems. The early LLRF systems used the well established technology based on discrete analogue amplitude and phase detectors and modulators. Today analogue LLRF systems can make use of advanced vector demodulators and modulators combined with a fast computer controlled analogue feed back loop. Feed forward control is implemented to operate the RF cavity in an open loop mode or to compensate for predictable perturbations. The paper will introduce the general design philosophy and show how it can be adapted to different tasks as controlling a synchrotron booster nc RF system at 500 MHz, or superconducting storage ring RF cavities, as well as a linear accelerator at 176 MHz formed by a chain of individually driven and controlled superconducting λ/2 cavities.

  14. The statistical analysis of failure of a MEVATRON77 DX67 linear accelerator over a ten year period

    CERN Document Server

    Aoyama, H; Tahara, S; Uno, H; Kadohisa, S; Azuma, Y; Nakagiri, Y; Hiraki, Y

    2003-01-01

    A linear accelerator (linac) takes a leading role in radiation therapy. A linac consists of complicated main parts and systems and it is required that highly accurate operational procedures should be maintained. Operational failure occurs for various reasons. In this report, the failure occurrences of one linac over a ten year period were recorded and analyzed. The subject model was a MEVATRON77 DX67 (Siemens, Inc). The failure rate for each system, the form classification of the contents of failure, the operation situation at the time of failure, and the average performance life of the main parts were totaled. Moreover, the relation between the number of therapies that patients received (operating efficiency) and the failure rate within that number and the relation between environment (temperature and humidity) and the failure rate attributed to other systems were analyzed. In this report, irradiation interruption was also included with situations where treatment was unable to begin in total for the number o...

  15. [Linear accelerator-based stereotactic radiosurgery for the treatment of trigeminal neuralgia. Nine years' experience in a single institution].

    Science.gov (United States)

    Serrano-Rubio, A A; Martinez-Manrique, J J; Revuelta-Gutierrez, R; Gomez-Amador, J L; Martinez-Anda, J J; Ponce-Gomez, J A; Moreno-Jimenez, S

    2014-09-16

    INTRODUCTION. Pharmacological treatment is the first therapeutic step towards controlling pain in trigeminal neuralgia, but 25-50% of patients become medication resistant. There are currently several surgical alternatives for treating these patients. AIM. To evaluate the effectiveness and safety of stereotactic radiosurgery for the treatment of patients with trigeminal neuralgia. PATIENTS AND METHODS. A follow-up study was conducted on 30 patients who underwent radiosurgery using a Novalis linear accelerator. Eighty per cent of the dosage was calculated at the isocentre, the entry zone of the root of the trigeminal nerve. The mean follow-up time was 27.5 months (range: 1-65 months). RESULTS. The mean age was 66 years (range: 36-87 years), with a time to progression of 7.1 years (range: 4-27 years). The distribution of the pain was from the right side (63.3%). Of the 30 patients, 27 experienced an improvement (90%) 1.6 months (range: 1 week-4 months) after the treatment; 10 patients (33.3%) scored grade I, and 17 patients (56.6%) obtained a score of grade II. During the follow-up, four patients (14.2%) suffered a relapse; two underwent re-irradiation. Time without recurrence was 62.7 months (range: 54.6-70.8 months). The rate of side effects was 76.7% and only three patients developed facial anaesthesia with loss of the corneal reflex. CONCLUSIONS. The use of the linear accelerator is an effective therapeutic option in the treatment of trigeminal neuralgia, since it provides adequate long-term control of the pain, reduces the use of medication and improves the quality of life.

  16. Non-planar electron motion during direct laser acceleration by a linearly/circularly polarized laser pulse

    Science.gov (United States)

    Khudik, Vladimir; Arefiev, Alexey; Zhang, Xi; Shvets, Gennady

    2016-10-01

    Direct Laser Acceleration (DLA) of electrons in plasma bubbles or ion channels is investigated in the general case of arbitrary polarization of laser pulse. When the laser pulse is linearly polarized, the laser electromagnetic field drives electron oscillations in the polarization plane, intuitively suggesting that the electron trajectory lies in the same plane. We show that strong modulations of the relativistic gamma-factor cause the free oscillations perpendicular to the plane of the driven motion to become unstable. As a consequence, out of plane displacements grow and the electron trajectory becomes strongly three-dimensional, even if it starts out planar during the early stage of the acceleration. For a circularly polarized laser pulse, electron end up moving along a helical trajectory with slowly changing helix radius. By deriving a set of dimensionless equations for paraxial ultra-relativistic electron motion, we have found an estimate for the maximum attainable electron energy for arbitrary laser and plasma parameters. This work was supported by DOE Grants DESC0007889 and DE-SC0010622, and by an AFOSR Grant FA9550-14-1-0045.

  17. Study of the electronics architecture for the mechanical stabilisation of the quadrupoles of the CLIC linear accelerator

    Science.gov (United States)

    Artoos, K.; Collette, C.; Fernandez Carmona, P.; Guinchard, M.; Hauviller, C.; Janssens, S.; Kuzmin, A.; Slaathaug, A.

    2010-11-01

    To reach a sufficient luminosity, the transverse beam sizes and emittances in future linear particle accelerators should be reduced to the nanometer level. Mechanical stabilisation of the quadrupole magnets is of the utmost importance for this. The piezo actuators used for this purpose can also be used to make fast incremental orientation adjustments with a nanometer resolution. The main requirements for the CLIC stabilisation electronics is a robust, low noise, low delay, high accuracy and resolution, low band and radiation resistant feedback control loop. Due to the high number of controllers (about 4000) a cost optimization should also be made. Different architectures are evaluated for a magnet stabilisation prototype, including the sensors type and configuration, partition between software and hardware for control algorithms, and optimization of the ADC/DAC converters. The controllers will be distributed along the 50 km long accelerator and a communication bus should allow external control. Furthermore, one might allow for an adaptive method to increase the S/N ratio of vibration measurements by combining seismometer measurements of adjacent magnets. Finally a list of open topics, the current limitations and the plans to overcome them will be presented.

  18. Upgrade of the MIT Linear Electrostatic Ion Accelerator (LEIA) for nuclear diagnostics development for Omega, Z and the NIF.

    Science.gov (United States)

    Sinenian, N; Manuel, M J-E; Zylstra, A B; Rosenberg, M; Waugh, C J; Rinderknecht, H G; Casey, D T; Sio, H; Ruszczynski, J K; Zhou, L; Gatu Johnson, M; Frenje, J A; Séguin, F H; Li, C K; Petrasso, R D; Ruiz, C L; Leeper, R J

    2012-04-01

    The MIT Linear Electrostatic Ion Accelerator (LEIA) generates DD and D(3)He fusion products for the development of nuclear diagnostics for Omega, Z, and the National Ignition Facility (NIF). Significant improvements to the system in recent years are presented. Fusion reaction rates, as high as 10(7) s(-1) and 10(6) s(-1) for DD and D(3)He, respectively, are now well regulated with a new ion source and electronic gas control system. Charged fusion products are more accurately characterized, which allows for better calibration of existing nuclear diagnostics. In addition, in situ measurements of the on-target beam profile, made with a CCD camera, are used to determine the metrology of the fusion-product source for particle-counting applications. Finally, neutron diagnostics development has been facilitated by detailed Monte Carlo N-Particle Transport (MCNP) modeling of neutrons in the accelerator target chamber, which is used to correct for scattering within the system. These recent improvements have resulted in a versatile platform, which continues to support the existing nuclear diagnostics while simultaneously facilitating the development of new diagnostics in aid of the National Ignition Campaign at the National Ignition Facility.

  19. Technologies of image guidance and the development of advanced linear accelerator systems for radiotherapy.

    Science.gov (United States)

    Wu, Vincent W C; Law, Maria Y Y; Star-Lack, Josh; Cheung, Fion W K; Ling, C Clifton

    2011-01-01

    As advanced radiotherapy approaches for targeting the tumor and sparing the normal tissues have been developed, the image guidance of therapy has become essential to directing and confirming treatment accuracy. To approach these goals, image guidance devices now include kV on-board imagers, kV/MV cone-beam CT systems, CT-on-rails, and mobile and in-room radiographic/fluoroscopic systems. Nonionizing sources, such as ultrasound and optical systems, and electromagnetic devices have been introduced to monitor or track the patient and/or tumor positions during treatment. In addition, devices have been designed specifically for monitoring and/or controlling respiratory motion. Optimally, image-guided radiation therapy systems should possess 3 essential elements: (1) 3D imaging of soft tissues and tumors, (2) efficient acquisition and comparison of the 3D images, and (3) an efficacious process for clinically meaningful intervention. Understanding and using these tools effectively is central to current radiotherapy practice. The implementation and integration of these devices continue to carry practical challenges, which emphasize the need for further development of the technologies and their clinical applications.

  20. Data Normalization to Accelerate Training for Linear Neural Net to Predict Tropical Cyclone Tracks

    Directory of Open Access Journals (Sweden)

    Jian Jin

    2015-01-01

    Full Text Available When pure linear neural network (PLNN is used to predict tropical cyclone tracks (TCTs in South China Sea, whether the data is normalized or not greatly affects the training process. In this paper, min.-max. method and normal distribution method, instead of standard normal distribution, are applied to TCT data before modeling. We propose the experimental schemes in which, with min.-max. method, the min.-max. value pair of each variable is mapped to (−1, 1 and (0, 1; with normal distribution method, each variable’s mean and standard deviation pair is set to (0, 1 and (100, 1. We present the following results: (1 data scaled to the similar intervals have similar effects, no matter the use of min.-max. or normal distribution method; (2 mapping data to around 0 gains much faster training speed than mapping them to the intervals far away from 0 or using unnormalized raw data, although all of them can approach the same lower level after certain steps from their training error curves. This could be useful to decide data normalization method when PLNN is used individually.

  1. An acceleration technique for the Gauss-Seidel method applied to symmetric linear systems

    Directory of Open Access Journals (Sweden)

    Jesús Cajigas

    2014-06-01

    Full Text Available A preconditioning technique to improve the convergence of the Gauss-Seidel method applied to symmetric linear systems while preserving symmetry is proposed. The preconditioner is of the form I + K and can be applied an arbitrary number of times. It is shown that under certain conditions the application of the preconditioner a finite number of steps reduces the matrix to a diagonal. A series of numerical experiments using matrices from spatial discretizations of partial differential equations demonstrates that both versions of the preconditioner, point and block version, exhibit lower iteration counts than its non-symmetric version. Resumen. Se propone una técnica de precondicionamiento para mejorar la convergencia del método Gauss-Seidel aplicado a sistemas lineales simétricos pero preservando simetría. El precondicionador es de la forma I + K y puede ser aplicado un número arbitrario de veces. Se demuestra que bajo ciertas condiciones la aplicación del precondicionador un número finito de pasos reduce la matriz del sistema precondicionado a una diagonal. Una serie de experimentos con matrices que provienen de la discretización de ecuaciones en derivadas parciales muestra que ambas versiones del precondicionador, por punto y por bloque, muestran un menor número de iteraciones en comparación con la versión que no preserva simetría.

  2. Mechanical quality assurance using light field for linear accelerators with camera calibration.

    Science.gov (United States)

    Park, Kwangwoo; Choi, Wonhoon; Keum, Ki Chang; Lee, Ho; Yoon, Jeongmin; Lee, Chang Geol; Lee, Ik Jae; Cho, Jaeho

    2016-02-01

    Mechanical Quality Assurance (QA) is important to assure spatially precise delivery of external-beam radiation therapy. As an alternative to the conventional-film based method, we have developed a new tool for mechanical QA of LINACs which uses a light field rather than radiation. When light passes through the collimator, a shadow is projected onto a piece of translucent paper and the resulting image is captured by a digital camera via a mirror. With this method, we evaluated the position of the LINAC isocenter and the accuracy of the gantry, collimator, and couch rotation. We also evaluated the accuracy of the digital readouts of the gantry, collimator, and couch rotation. In addition, the treatment couch position indicator was tested. We performed camera calibration as an essential pre-requisite for quantitative measurements of the position of isocenter, the linear motion of the couch, and the rotation angles of the gantry and collimator. Camera calibration reduced the measurement error to submillimeter based on uncertainty in pixel size of the image, while, without calibration, the measurement error of up to 2 mm could occur for an object with a length of 5 cm.

  3. Two troubles and maintenance of SIEMENS primus-high linear accelerator%西门子PRIMUS加速器故障排除

    Institute of Scientific and Technical Information of China (English)

    郭初晓; 邵健

    2013-01-01

    The medical linear accelerator is one of the latest large equipment for radiotherapy. Its structure and its maintenance service are complicated. Because Siemens Healthcare will stop producing any medical linear accelerator in the future, there will be some increasing uncertainties about the repair and maintenance service of the Siemens accelerators. We provide two cases of breakdown maintenance of PRIMUS accelerator in our hospital, for reference.%医用直线加速器是最新的大型放射治疗设备,其结构和维修较为复杂,且该设备制造商已确定今后不再制造医用直线加速器,因此医院使用的西门子加速器的维修和保养显得尤为重要.

  4. Accelerated oral nanomedicine discovery from miniaturized screening to clinical production exemplified by paediatric HIV nanotherapies

    Science.gov (United States)

    Giardiello, Marco; Liptrott, Neill J.; McDonald, Tom O.; Moss, Darren; Siccardi, Marco; Martin, Phil; Smith, Darren; Gurjar, Rohan; Rannard, Steve P.; Owen, Andrew

    2016-10-01

    Considerable scope exists to vary the physical and chemical properties of nanoparticles, with subsequent impact on biological interactions; however, no accelerated process to access large nanoparticle material space is currently available, hampering the development of new nanomedicines. In particular, no clinically available nanotherapies exist for HIV populations and conventional paediatric HIV medicines are poorly available; one current paediatric formulation utilizes high ethanol concentrations to solubilize lopinavir, a poorly soluble antiretroviral. Here we apply accelerated nanomedicine discovery to generate a potential aqueous paediatric HIV nanotherapy, with clinical translation and regulatory approval for human evaluation. Our rapid small-scale screening approach yields large libraries of solid drug nanoparticles (160 individual components) targeting oral dose. Screening uses 1 mg of drug compound per library member and iterative pharmacological and chemical evaluation establishes potential candidates for progression through to clinical manufacture. The wide applicability of our strategy has implications for multiple therapy development programmes.

  5. Accelerated oral nanomedicine discovery from miniaturized screening to clinical production exemplified by paediatric HIV nanotherapies

    Science.gov (United States)

    Giardiello, Marco; Liptrott, Neill J.; McDonald, Tom O.; Moss, Darren; Siccardi, Marco; Martin, Phil; Smith, Darren; Gurjar, Rohan; Rannard, Steve P.; Owen, Andrew

    2016-01-01

    Considerable scope exists to vary the physical and chemical properties of nanoparticles, with subsequent impact on biological interactions; however, no accelerated process to access large nanoparticle material space is currently available, hampering the development of new nanomedicines. In particular, no clinically available nanotherapies exist for HIV populations and conventional paediatric HIV medicines are poorly available; one current paediatric formulation utilizes high ethanol concentrations to solubilize lopinavir, a poorly soluble antiretroviral. Here we apply accelerated nanomedicine discovery to generate a potential aqueous paediatric HIV nanotherapy, with clinical translation and regulatory approval for human evaluation. Our rapid small-scale screening approach yields large libraries of solid drug nanoparticles (160 individual components) targeting oral dose. Screening uses 1 mg of drug compound per library member and iterative pharmacological and chemical evaluation establishes potential candidates for progression through to clinical manufacture. The wide applicability of our strategy has implications for multiple therapy development programmes. PMID:27767027

  6. The Nano-X Linear Accelerator: A Compact and Economical Cancer Radiotherapy System Incorporating Patient Rotation.

    Science.gov (United States)

    Eslick, Enid M; Keall, Paul J

    2015-10-01

    Rapid technological improvements in radiotherapy delivery results in improved outcomes to patients, yet current commercial systems with these technologies on board are costly. The aim of this study was to develop a state-of-the-art cancer radiotherapy system that is economical and space efficient fitting with current world demands. The Nano-X system is a compact design that is light weight combining a patient rotation system with a vertical 6 MV fixed beam. In this paper, we present the Nano-X system design configuration, an estimate of the system dimensions and its potential impact on shielding cost reductions. We provide an assessment of implementing such a radiotherapy system clinically, its advantages and disadvantages compared to a compact conventional gantry rotating linac. The Nano-X system has several differentiating features from current radiotherapy systems, it is [1] compact and therefore can fit into small vaults, [2] light weight, and [3] engineering efficient, i.e., it rotates a relatively light component and the main treatment delivery components are not under rotation (e.g., DMLCs). All these features can have an impact on reducing the costs of the system. In terms of shielding requirements, leakage radiation was found to be the dominant contributor to the Nano-X vault and as such no primary shielding was necessary. For a low leakage design, the Nano-X vault footprint and concrete volume required is 17 m2 and 35 m3 respectively, compared to 54 m2 and 102 m3 for a conventional compact linac vault, resulting in decreased costs in shielding. Key issues to be investigated in future work are the possible patient comfort concerns associated with the patient rotation system, as well as the magnitude of deformation and subsequent adaptation requirements.

  7. Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators.

    Science.gov (United States)

    Cardenas, Carlos E; Nitsch, Paige L; Kudchadker, Rajat J; Howell, Rebecca M; Kry, Stephen F

    2016-07-08

    Out-of-field doses from radiotherapy can cause harmful side effects or eventually lead to secondary cancers. Scattered doses outside the applicator field, neutron source strength values, and neutron dose equivalents have not been broadly investigated for high-energy electron beams. To better understand the extent of these exposures, we measured out-of-field dose characteristics of electron applicators for high-energy electron beams on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at various energy levels. Out-of-field dose profiles and percent depth-dose curves were measured in a Wellhofer water phantom using a Farmer ion chamber. Neutron dose was assessed using a combination of moderator buckets and gold activation foils placed on the treatment couch at various locations in the patient plane on both the Varian 21iX and Elekta Versa HD linear accelerators. Our findings showed that out-of-field electron doses were highest for the highest electron energies. These doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. The Elekta linear accelerator had higher electron out-of-field doses than the Varian units examined, and the Elekta dose profiles exhibited a second dose peak about 20 to 30 cm from central-axis, which was found to be higher than typical out-of-field doses from photon beams. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. With respect to neutron dosimetry, Q values and neutron dose equivalents increased with electron beam energy. Neutron contamination from electron beams was found to be much lower than that from photon beams. Even though the neutron dose equivalent for electron beams represented a small portion of neutron doses observed under photon beams, neutron doses from electron beams may need to be considered for special cases.

  8. Comparison of two methods for assessing leakage radiation dose around the head of the medical linear accelerators

    Institute of Scientific and Technical Information of China (English)

    Ehab M Attalla

    2013-01-01

    Objective:The aim of this study was to measure the leakage by two methods with ion chamber and ready packs film, and to investigate the feasibility and the advantages of using two dosimetry methods for assessing leakage radiation around the head of the linear accelerators. Methods:Measurements were performed using a 30 cm3 ion chamber;the gantry at 0°, the X-ray head at 0°, the field size at between the central axis and a plane surface at a FSD of 100 as a reference, a series of concentric circles having radi of 50, 75, and 100 cm with their common centre at the reference point. The absorbed dose was measured at the reference point, and this would be used as the reference dose. With the diaphragm closed, the measurements were taken along the circumference of the three circles and at 45° intervals. Results:Leakage radiations while the treatment head was in the vertical position varied between 0.016%–0.04%. With the head lying horizontal y, leak-age radiation was the same order magnitude and varied between 0.02%–0.07%. In the second method, the verification was accomplished by closing the col imator jaws and covering the head of the treatment unit with the ready pack films. The films were marked to permit the determination of their positions on the machine after exposed and processed. With the diaphragm closed, and the ready packs films around the linear accelerator the beam turned on for 2500 cGy (2500 MU). The optical den-sity of these films was measured and compared with this of the reference dose. Leakage radiation varied according to the film positions and the magnitude of leakage was between 0.005%–0.075%. Conclusion:The dif erences between the values of the leakage radiation levels observed at dif erent measurement points do not only reflect dif erences in the ef ective shielding thickness of the head wal , but are also related to dif erences in the distances between the target and the measurement points. The experimental errors involved in dosimetric

  9. Warfarin Accelerates Ectopic Mineralization in Abcc6−/− Mice: Clinical Relevance to Pseudoxanthoma Elasticum

    OpenAIRE

    2013-01-01

    Pseudoxanthoma elasticum (PXE) is a multisystem ectopic mineralization disorder caused by mutations in the ABCC6 gene. Warfarin, a commonly used anticoagulant, is associated with increased mineralization of the arterial blood vessels and cardiac valves. We hypothesized that warfarin may accelerate ectopic tissue mineralization in PXE, with clinical consequences. To test this hypothesis, we developed a model in which Abcc6−/− mice, which recapitulate features of PXE, were fed a diet supplement...

  10. Benefits of Non-Linear Mixed Effect Modeling and Optimal Design : Pre-Clinical and Clinical Study Applications

    OpenAIRE

    Ernest II, Charles Steven

    2013-01-01

    Despite the growing promise of pharmaceutical research, inferior experimentation or interpretation of data can inhibit breakthrough molecules from finding their way out of research institutions and reaching patients. This thesis provides evidence that better characterization of pre-clinical and clinical data can be accomplished using non-linear mixed effect modeling (NLMEM) and more effective experiments can be conducted using optimal design (OD).  To demonstrate applicability of NLMEM and OD...

  11. Comparison of the dosimetric parameters in linear accelerators with flattening filter-free (FFF) and flattening filter (FF)

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Anderson S.; Rostelato, Maria Elisa C.M.; Zeituni, Carlos A.; Moura, Eduardo S.; Rodrigues, Bruna T.; Souza, Daiane C.; Tiezzi, Rodrigo; Souza, Carla D.; Melo, Emerson R.; Camargo, Anderson R.; Batista, Talita Q., E-mail: asorgatti@hotmail.com, E-mail: elisaros@ipen.br, E-mail: czeituni@ipen.br, E-mail: edusantos_moura@ig.com.br, E-mail: bteigarodrigues@gmail.com, E-mail: dchristini2013@gmail.com, E-mail: rtiezzi@ipen.br, E-mail: carladdsouza@yahoo.com.br, E-mail: s, E-mail: emermelo@hotmail.com, E-mail: anderson.rogerio.c@hotmail.com, E-mail: ta_litterqbatista@hotmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    This paper discusses the main features associated with the dosimetric parameters between FFF and FF Linacs. A set of Varian TrueBeam Linac and Varian 23EX dosimetric measurements was acquired to perform the experimental measurements. The dose measurements were carried out in a water Blue phantom, with a waterproof ionization chambers: farmer ionization chamber (0.6 cm{sup 3}) and Exradin A1SL(0.053 cm{sup 3}) , for fields 5 x 5, 8 x 8, 10 x 10, 15 x 15, 30 x 30 cm{sup 2}. The 6 MV FFF and FF was the energy used in this work. Percent Depth Dose (PDD) was the dosimetric parameters evaluated using a fixed Source Surface Distance of 100 cm. One depth were applied for the measurements, 10 cm (central axis) from the water surface. The 6 MV FFF showed less penetrating than the 6 MV FF. This is due to the removal flattening filter causes more lower energy photons on the central axis. The field sizes were equivalent for both FFF and FF. The main advantage in operate linear accelerators without flattening filter is due to the high doses rates delivered during the treatment. High doses rates could reduce the patient treatment time and may be beneficial for some treatment techniques such as IMRT and SRT. (author)

  12. Resultant linear acceleration of an instrumented head form does not differ between junior and collegiate taekwondo athletes’ kicks

    Institute of Scientific and Technical Information of China (English)

    David O’Sullivan; Gabriel P. Fife; Willy Pieter; Taehee Lim; Insik Shin

    2016-01-01

    Objective: The purpose of this study was to compare the effects of various taekwondo kicks and age (school level) in absolute terms and relative body mass on the resultant linear acceleration (RLA) of an instrumented head form. Methods: Forty-eight male (middle school: 16; high school: 16; university: 16) taekwondo athletes were recruited for this study. Subjects performed 10 turning, 10 jump spinning hook, and 10 jump back kicks on a Hybrid II head mounted on a height-adjustable frame. Results: A 2-way (School × Kick) MANOVA was used to determine the differences in RLA between schools (age groups) by type of kick. There was no univariate School main effect for absolute RLA (η2=0.06) and RLA relative to body mass (η2=0.06). No univariate Kick main effects were found for absolute (η2=0.06) and relative RLA (η2=0.06). Conclusion: It is of concern that RLA did not significantly differ between school levels, implying that young taekwondo athletes generate similar forces to their adult counterparts, possibly exposing young athletes to an increased risk for head injuries.

  13. Environmental Assessment for US Department of Energy support of an Iowa State University Linear Accelerator Facility at Ames, Iowa

    Energy Technology Data Exchange (ETDEWEB)

    1990-05-01

    The proposed Department of Energy (DOE) action is financial and technical support of construction and initial operation of an agricultural commodity irradiator (principally for meat), employing a dual mode electron beam generator capable of producing x-rays, at the Iowa State University Linear Accelerator located at Ames, Iowa. The planned pilot commercial-scale facility would be used for the following activities: conducting irradiation research on agricultural commodities, principally meats; in the future, after the pilot phase, as schedules permit, possibly conducting research on other, non-edible materials; evaluating effects of irradiation on nutritional and sensory quality of agricultural products; demonstrating the efficiency of the process to control or eliminate pathogens, and/or to prolong the commodities' post-harvest shelf-life via control or elimination of bacteria, fungi, and/or insects; providing information to the public on the benefits, safety and risks of irradiated agricultural commodities; determining consumer acceptability of the irradiated products; providing data for use by regulatory agencies in developing protocols for various treatments of Iowa agricultural commodities; and training operators, maintenance and quality control technicians, scientists, engineers, and staff of regulatory agencies in agricultural commodity irradiation technology. 14 refs., 5 figs.

  14. Inertial acceleration as a measure of linear vection: An alternative to magnitude estimation. Ph.D. Thesis

    Science.gov (United States)

    Carpenter-Smith, Theodore R.; Futamura, Robert G.; Parker, Donald E.

    1995-01-01

    The present study focused on the development of a procedure to assess perceived self-motion induced by visual surround motion - vection. Using an apparatus that permitted independent control of visual and inertial stimuli, prone observers were translated along their head x-axis (fore/aft). The observers' task was to report the direction of self-motion during passive forward and backward translations of their bodies coupled with exposure to various visual surround conditions. The proportion of 'forward' responses was used to calculate each observer's point of subjective equality (PSE) for each surround condition. The results showed that the moving visual stimulus produced a significant shift in the PSE when data from the moving surround condition were compared with the stationary surround and no-vision condition. Further, the results indicated that vection increased monotonically with surround velocities between 4 and 40/s. It was concluded that linear vection can be measured in terms of changes in the amplitude of whole-body inertial acceleration required to elicit equivalent numbers of 'forward' and 'backward' self-motion reports.

  15. Multiwavelength Spectral Models for SNR G347.3-0.5 from Non-Linear Shock Acceleration

    CERN Document Server

    Baring, M G; Slane, P O; Baring, Matthew G.; Ellison, Donald C.; Slane, Patrick O.

    2005-01-01

    The remnant G347.3-0.5 exhibits strong shell emission in the radio and X-ray bands, and has a purported detection in the TeV gamma-ray band by the CANGAROO-II telescope. The CANGAROO results were touted as evidence for the production of cosmic ray ions, a claim that has proven controversial due to constraining fluxes associated with a proximate unidentified EGRET source 3EG J1714-3857. HESS has now seen this source in the TeV band. The complex environment of the remnant renders modeling of its broadband spectrum sensitive to assumptions concerning the nature and parameters of the circumremnant medium. This paper explores a sampling of reasonable possibilities for multiwavelength spectral predictions from this source, using a non-linear model of diffusive particle acceleration at the shocked shell. The magnetic field strength, shell size and degree of particle cross-field diffusion act as variables to which the radio to X-ray to gamma-ray signal is sensitive. The modeling of the extant data constrains these va...

  16. SU-E-T-627: Failure Modes and Effect Analysis for Monthly Quality Assurance of Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Xie, J [Fudan University shanghai cancer center, Shanghai, Shanghai (China); Xiao, Y [Thomas Jefferson UniversityHospital, Philadelphia, PA (United States); Wang, J; Peng, J; Lu, S [Fudan University Shanghai Cancer Center, Shanghai, Shanghai (China); Hu, W [Fudan University Shanghai Caner Center, Shanghai, Shanghai (China)

    2014-06-15

    Purpose: To develop and implement a failure mode and effect analysis (FMEA) on routine monthly Quality Assurance (QA) tests (physical tests part) of linear accelerator. Methods: A systematic failure mode and effect analysis method was performed for monthly QA procedures. A detailed process tree of monthly QA was created and potential failure modes were defined. Each failure mode may have many influencing factors. For each factor, a risk probability number (RPN) was calculated from the product of probability of occurrence (O), the severity of effect (S), and detectability of the failure (D). The RPN scores are in a range of 1 to 1000, with higher scores indicating stronger correlation to a given influencing factor of a failure mode. Five medical physicists in our institution were responsible to discuss and to define the O, S, D values. Results: 15 possible failure modes were identified and all RPN scores of all influencing factors of these 15 failue modes were from 8 to 150, and the checklist of FMEA in monthly QA was drawn. The system showed consistent and accurate response to erroneous conditions. Conclusion: The influencing factors of RPN greater than 50 were considered as highly-correlated factors of a certain out-oftolerance monthly QA test. FMEA is a fast and flexible tool to develop an implement a quality management (QM) frame work of monthly QA, which improved the QA efficiency of our QA team. The FMEA work may incorporate more quantification and monitoring fuctions in future.

  17. Some folded issues related to over-shielded and unplanned rooms for medical linear accelerators - A case study

    Science.gov (United States)

    Muhammad, Wazir; Ullah, Asad; Hussain, Amjad; Ali, Nawab; Alam, Khan; Khan, Gulzar; Matiullah; Maeng, Seongjin; Lee, Sang Hoon

    2015-08-01

    A medical linear accelerator (LINAC) room must be properly shielded to limit the outside radiation exposure to an acceptable safe level defined by individual state and international regulations. However, along with this prime objective, some additional issues are also important. The current case-study was designed to unfold the issues related to over-shielded and unplanned treatment rooms for LINACs. In this connection, an apparently unplanned and over-shielded treatment room of 610 × 610 cm2 in size was compared with a properly designed treatment room of 762 × 762 cm2 in size ( i.e., by following the procedures and recommendations of the IAEA Safety Reports Series No. 47 and NCRP 151). Evaluation of the unplanned room indicated that it was over-shielded and that its size was not suitable for total body irradiation (TBI), although the license for such a treatment facility had been acquired for the installed machine. An overall 14.96% reduction in the total shielding volume ( i.e., concrete) for an optimally planned room as compared to a non-planned room was estimated. Furthermore, the inner room's dimensions were increased by 25%, in order to accommodate TBI patients. These results show that planning and design of the treatment rooms are imperative to avoid extra financial burden to the hospitals and to provide enough space for easy and safe handling of the patients. A spacious room is ideal for storing treatment accessories and facilitates TBI treatment.

  18. TECHNIQUE OF ESTIMATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. PART 1. DEPENDANCE OF THE MECHANICAL PARAMETERS OF LINAC’S GANTRY

    Directory of Open Access Journals (Sweden)

    Y. V. Tsitovich

    2015-01-01

    Full Text Available To ensure the safety of radiation oncology patients needed to provide a consistent functional characteristics of the medical linear electron accelerators, which affect the accuracy of dose delivery. To this end, their quality control procedures, which include the calibration of radiation output of the linear accelerator, the error in determining the dose reference value during which must not exceed 2 %, is provided. The aim is to develop a methodology for determining the error in determining this value, depending on the mechanical charachteristics of the linac’s gantry. To achieve the objectives have been carried out dosimetric measurements of Trilogy S/N 3567 linac dose distributions, on the basis of which dose errors depending on the accuracy setting the zero position of the gantry and the deviation of the gantry rotation isocenter were obtained. It was found that the greatest impact on the value of the error has gantry rotation isocenter deviation in a plane perpendicular to the plane of incidence of the radiation beam (up to 3,64% for the energy of 6 MeV. Dose errors caused by tilting the gantry and its isocenter deviation in the plane of incidence of the beam were highest for 18 MeV energy and reached –0,7 % and –0,9 % respectively. Thus, it is possible to express the results of periodic quality control of the linear accelerator ganty in terms of dose and use them to conduct a comprehensive assessment of the possibility of clinical use of a linear accelerator for oncology patients irradiation in case of development of techniques that allow to analyze the influence of the rest of its technical and dosimetric parameters for error in dose.

  19. Potential clinical impact of laser-accelerated beams in cancer ion therapy

    Energy Technology Data Exchange (ETDEWEB)

    Obcemea, Ceferino

    2016-09-01

    In this article, I present three advantages of plasma-accelerated ion beams for cancer therapy. I discuss how: 1. low-emittance and well-collimated beams are advantageous in proximal normal tissue-sparing; 2. highly-peaked quasi-monoenergetic beams are ideal for fast energy selection and switching in Pencil Beam Scanning (PBS) as a treatment delivery; 3. high fluence and ultra-short pulse delivery produce collective excitations in the medium and enhance the stopping power. This in turn produces denser ionization track signatures (spurs, blobs, etc.) in target tumors, higher linear energy transfer, higher Bragg peak, and higher radiobiological effectiveness at the micro-level.

  20. An Analytic Linear Accelerator Source Model for Monte Carlo dose calculations. II. Model Utilization in a GPU-based Monte Carlo Package and Automatic Source Commissioning

    CERN Document Server

    Tian, Zhen; Li, Yongbao; Shi, Feng; Jiang, Steve B; Jia, Xun

    2015-01-01

    We recently built an analytical source model for GPU-based MC dose engine. In this paper, we present a sampling strategy to efficiently utilize this source model in GPU-based dose calculation. Our source model was based on a concept of phase-space-ring (PSR). This ring structure makes it effective to account for beam rotational symmetry, but not suitable for dose calculations due to rectangular jaw settings. Hence, we first convert PSR source model to its phase-space let (PSL) representation. Then in dose calculation, different types of sub-sources were separately sampled. Source sampling and particle transport were iterated. So that the particles being sampled and transported simultaneously are of same type and close in energy to alleviate GPU thread divergence. We also present an automatic commissioning approach to adjust the model for a good representation of a clinical linear accelerator . Weighting factors were introduced to adjust relative weights of PSRs, determined by solving a quadratic minimization ...

  1. Using of beam spoilers in linear accelerators with photons of 10 MV; Empleo de degradadores del haz en aceleradores lineales con fotones de 10 MV

    Energy Technology Data Exchange (ETDEWEB)

    Sansogne, R.; Palacios, V.; Arbiser, S. [Vidt Centro Medico- CETRO. Vidt 1924- (1428) Buenos Aires (Argentina)

    1998-12-31

    This work come along of the necessity to utilize an unique High-Energy Electron Linear Accelerator (10 MV) for radiant treatments which require higher doses in the surface levels of tissue. It is analyzed the interposition of acrylic degraders (spoilers) in the beam, especially for opposed and parallel fields in the cases of head and neck. It was analyzed the possible combinations of the following parameters: 1) Field sizes defined at isocenter (100 cm) 6 x 6 cm{sup 2}, 8 x 8 cm{sup 2} and 10 x 10 cm{sup 2} ; 2) Surface-spoiler distance (DSS) of 4, 7 and 10 cm; 3) Spoilers with different thickness 1.1 and 1.5 cm. It was observed a displacement of the maximum dose toward the surface, and an increase in the percentile doses in the build-up zone when the spoiler is nearing and/or increasing its thickness. It is verified that the use of spoilers, support the symmetry and plane of the beam inside of the clinically acceptable margins. When the results obtained are analyzed then it is proposed as a calculation method to incorporate an attenuation factor. (Author)

  2. Development of a Magnetron Resonance Frequency Auto Tuning System for Medical Xband [9300 MHz] RF Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Sung Su; Lee, Byung Cheol [University of Science and Technology, Daejeon (Korea, Republic of); Kim, Yujong; Park, Hyung Dal; Lee, Byeong-No; Joo, Youngwoo; Cha, Hyungki; Lee, Soo Min; Song, Ki Baek [KAERI, Daejeon (Korea, Republic of); Lee, Seung Hyun [Sungkyunkwan University, Suwon (Korea, Republic of)

    2015-05-15

    The total components of the accelerator are the magnetron, electron gun, accelerating structure, a set of solenoid magnets, four sets of steering coils, a modulator, and a circulator. One of the accelerator components of the accelerating structure is made of oxygen-free high-conductivity copper (OFHC), and its volume is changed according to the ambient temperature. As the volume changes, the resonant frequency of the accelerating structure is changed. Accordingly, the resonance frequency is mismatched between the source of the magnetron and the accelerating structure. An automatic frequency tuning system is automatically matched with the resonant frequency of the magnetron and accelerating structure, which allows a high output power and reliable accelerator operation. An automatic frequency tuning system is composed of a step motor control part for correcting the frequency of the source and power measuring parts, i.e., the forward and reflected power between the magnetron and accelerating structure. In this paper, the design, fabrication, and RF power test of the automatic frequency tuning system for the X-band linac are presented. A frequency tuning system was developed to overcome an unstable accelerator operation owing to the frequency mismatch between the magnetron and accelerating structure. The frequency measurement accuracy is 100 kHz and 0.72 degree per pulse.

  3. Megavoltage Image-Based Dynamic Multileaf Collimator Tracking of a NiTi Stent in Porcine Lungs on a Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Poulsen, Per R., E-mail: perpolse@rm.dk [Department of Oncology, Aarhus University Hospital, Aarhus (Denmark); Carl, Jesper; Nielsen, Jane; Nielsen, Martin S.; Thomsen, Jakob B. [Department of Medical Physics, Aalborg Hospital, University of Aarhus, Aalborg (Denmark); Jensen, Henrik K. [Department of Pulmonary Medicine, Aalborg Hospital, University of Aarhus, Aalborg (Denmark); Kjaergaard, Benedict; Zepernick, Peter R. [Department of Thoracic Surgery, Aalborg Hospital, University of Aarhus, Aalborg (Denmark); Worm, Esben; Fledelius, Walther [Department of Oncology, Aarhus University Hospital, Aarhus (Denmark); Cho, Byungchul [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Sawant, Amit [University of Texas Southwestern Medical Center, Dallas, TX (United States); Ruan, Dan [Department of Radiation Oncology, University of California-Los Angeles, Los Angeles, CA (United States); Keall, Paul J. [Department of Radiation Oncology, Stanford University, Stanford, CA (United States); Sydney Medical School, University of Sydney, Sydney, New South Wales (Australia)

    2012-02-01

    Purpose: To investigate the accuracy and potential limitations of MV image-based dynamic multileaf collimator (DMLC) tracking in a porcine model on a linear accelerator. Methods and Materials: A thermo-expandable NiTi stent designed for kilovoltage (kV) X-ray visualization of lung lesions was inserted into the bronchia of three anaesthetized Goettingen minipigs. A four-dimensional computed tomography scan was used for planning a five-field conformal treatment with circular multileaf collimator (MLC) apertures. A 22.5 Gy single fraction treatment was delivered to the pigs. The peak-to-peak stent motion was 3 to 8 mm, with breathing periods of 1.2 to 4 s. Before treatment, X-ray images were used for image-guided setup based on the stent. During treatment delivery, continuous megavoltage (MV) portal images were acquired at 7.5 Hz. The stent was segmented in the images and used for continuous adaptation of the MLC aperture. Offline, the tracking error in beam's eye view of the treatment beam was calculated for each MV image as the difference between the MLC aperture center and the segmented stent position. The standard deviations of the systematic error {Sigma} and the random error {sigma} were determined and compared with the would-be errors for a nontracking treatment with pretreatment image-guided setup. Results: Reliable stent segmentation was obtained for 11 of 15 fields. Segmentation failures occurred when image contrast was dominated by overlapping anatomical structures (ribs, diaphragm) rather than by the stent, which was designed for kV rather than MV X-ray visibility. For the 11 fields with reliable segmentation, {Sigma} was 0.5 mm/0.4 mm in the two imager directions, whereas {sigma} was 0.5 mm/1.1 mm. Without tracking, {Sigma} and {sigma} would have been 1.7 mm/1.4 mm and 0.8 mm/1.4 mm, respectively. Conclusion: For the first time, in vivo DMLC tracking has been demonstrated on a linear accelerator showing the potential for improved targeting accuracy

  4. The effect of a paraffin screen on the neutron dose at the maze door of a 15 MV linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Krmar, M.; Kuzmanović, A. [Physics Department, Faculty of Science, University of Novi Sad, Novi Sad 21000 (Serbia); Nikolić, D. [National Institute for Nanotechnology, Edmonton, Alberta T6G 2M9 (Canada); Kuzmanović, Z. [International Medical Centers, Banja Luka 78000, Republika Srpska, Bosnia and Herzegovina (Bosnia and Herzegowina); Ganezer, K. [Physics Department, California State University Dominguez Hills, Carson, California 90747 (United States)

    2013-08-15

    Purpose: The purpose of this study was to explore the effects of a paraffin screen located at various positions in the maze on the neutron dose equivalent at the maze door.Methods: The neutron dose equivalent was measured at the maze door of a room containing a 15 MV linear accelerator for x-ray therapy. Measurements were performed for several positions of the paraffin screen covering only 27.5% of the cross-sectional area of the maze. The neutron dose equivalent was also measured at all screen positions. Two simple models of the neutron source were considered in which the first assumed that the source was the cross-sectional area at the inner entrance of the maze, radiating neutrons in an isotropic manner. In the second model the reduction in the neutron dose equivalent at the maze door due to the paraffin screen was considered to be a function of the mean values of the neutron fluence and energy at the screen.Results: The results of this study indicate that the equivalent dose at the maze door was reduced by a factor of 3 through the use of a paraffin screen that was placed inside the maze. It was also determined that the contributions to the dosage from areas that were not covered by the paraffin screen as viewed from the dosimeter, were 2.5 times higher than the contributions from the covered areas. This study also concluded that the contributions of the maze walls, ceiling, and floor to the total neutron dose equivalent were an order of magnitude lower than those from the surface at the far end of the maze.Conclusions: This study demonstrated that a paraffin screen could be used to reduce the neutron dose equivalent at the maze door by a factor of 3. This paper also found that the reduction of the neutron dose equivalent was a linear function of the area covered by the maze screen and that the decrease in the dose at the maze door could be modeled as an exponential function of the product φ·E at the screen.

  5. SU-E-T-354: Efficient and Enhanced QA Testing of Linear Accelerators Using a Real-Time Beam Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Jung, J; Farrokhkish, M; Norrlinger, B; Wang, Y [Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Heaton, R; Jaffray, D; Islam, M [Princess Margaret Cancer Centre, Toronto, Ontario (Canada); University of Toronto, Toronto, Ontario (Canada)

    2015-06-15

    Purpose: To investigate the feasibility of performing routine QA tests of linear accelerators (Linac) using the Integral Quality Monitoring (IQM) system. The system, consisting of a 1-D sensitivity gradient large area ion-chamber mounted at the collimator, allows automatic collection and analysis of beam data. Methods: The IQM was investigated to perform several QA constancy tests, similar to those recommended by AAPM TG142, of a Linac including: beam output, MLC calibration, beam symmetry, relative dose factor (RDF), dose linearity, output as a function of gantry angle and dose rate. All measurements by the IQM system accompanied a reference measurement using a conventional dosimetry system and were performed on an Elekta Infinity Linac with Agility MLC. The MLC calibration check is done using a Picket-Fence type 2×10cm{sup 2} field positioned at different off-axis locations along the chamber gradient. Beam symmetry constancy values are established by signals from an 4×4cm{sup 2} aperture located at various off-axis positions; the sensitivity of the test was determined by the changes in the signals in response to a tilt in the beam. The data for various square field sizes were used to develop a functional relationship with RDF. Results: The IQM tracked the beam output well within 1% of the reference ion-chamber readings. The Picket-Fence type field test detected a 1mm shift error of one MLC bank. The system was able to detect 2.5% or greater beam asymmetry. The IQM results for all other QA tests were found to agree with the reference values to within 0.5%. Conclusion: It was demonstrated that the IQM system can effectively monitor the Linac performance parameters for the purpose of routine QA constancy tests. With minimum user interactions a comprehensive set of tests can be performed efficiently, allowing frequent monitoring of the Linac. The presenting author’s salary is funded by the manufacturer of the QA device. All the other authors have financial

  6. Optimal composite scores for longitudinal clinical trials under the linear mixed effects model.

    Science.gov (United States)

    Ard, M Colin; Raghavan, Nandini; Edland, Steven D

    2015-01-01

    Clinical trials of chronic, progressive conditions use rate of change on continuous measures as the primary outcome measure, with slowing of progression on the measure as evidence of clinical efficacy. For clinical trials with a single prespecified primary endpoint, it is important to choose an endpoint with the best signal-to-noise properties to optimize statistical power to detect a treatment effect. Composite endpoints composed of a linear weighted average of candidate outcome measures have also been proposed. Composites constructed as simple sums or averages of component tests, as well as composites constructed using weights derived from more sophisticated approaches, can be suboptimal, in some cases performing worse than individual outcome measures. We extend recent research on the construction of efficient linearly weighted composites by establishing the often overlooked connection between trial design and composite performance under linear mixed effects model assumptions and derive a formula for calculating composites that are optimal for longitudinal clinical trials of known, arbitrary design. Using data from a completed trial, we provide example calculations showing that the optimally weighted linear combination of scales can improve the efficiency of trials by almost 20% compared with the most efficient of the individual component scales. Additional simulations and analytical results demonstrate the potential losses in efficiency that can result from alternative published approaches to composite construction and explore the impact of weight estimation on composite performance.

  7. Technique in linear accelerator total body irradiation%直线加速器全身照射技术

    Institute of Scientific and Technical Information of China (English)

    张九堂; 伍志红; 鲁旭蔚; 何金莲

    2001-01-01

    This article describes the physical, technical, and dosimetric aspects of total body irradiation (TBI) that was carried out by using 6MV X-Ray from Varian 2300 C/D Linear Accelerator at a distance of 450 cm from target to the treatment table and at a gantry angle of 270°.The dose to lung tissue was limit by setting the individual lead compensators customized before, and using DPD-510 to monitor the absorbed dose of the reference point the absorbed dose in depth of half of body will be (Din+Dout)/2 after taking treatment in both AP position and PA position.%本文介绍了在直线加速器上实行全身照射的方法,包括治疗床的设计、测量装置的制作、实验参数的测定和照射方法。SSD=450 cm,机架角为270度,患者取侧卧位,前后野和后前野对穿照射,采用分段肺屏蔽办法控制肺的吸收剂量。用多通道半导体剂量仪进行剂量全程监测作为质量控制手段进行质量控制和实现质量保证,用入射表面剂量Din与出射表面剂量Dout之和的一半即(Din+Dout)/2作为对应入射方向上体中层面的吸收剂量。

  8. A model for the determination of the nominal potential for a linear accelerator; Un modelo para la determinacion del potencial nominal de un acelerador lineal

    Energy Technology Data Exchange (ETDEWEB)

    Gutt, F.; Silva, P.; Guerrero, R.; Diaz, J.; Colmenares, J. [Instituto Venezolano de Investigaciones Cientificas (IVIC), Laboratorio Secundario de Calibracion Dosimetrica (LSCD), Apartado 21827, Caracas 1020 A (Venezuela)

    1998-12-31

    The objective of the present work is to find a physical mathematical model based on the reason of the dose percentages at 10 and 20 cm depth, at 100 cm DFS and a 10 x 10 cm{sup 2} field. It was utilized literature data of new manufactured accelerators and those are in use in hospitals, which allow to prove the model under different conditions. Our objective consists only to obtain a model that verifies the nominal potential for a linear accelerator, but without pretending that such a model to be used to calculate any one factor to determination of absorbed dose. (Author)

  9. Improvements in dose accuracy delivered with static-MLC IMRT on an integrated linear accelerator control system

    Energy Technology Data Exchange (ETDEWEB)

    Li Ji; Wiersma, Rodney D.; Stepaniak, Christopher J.; Farrey, Karl J.; Al-Hallaq, Hania A. [Department of Radiation and Cellular Oncology, University of Chicago, 5758 South Maryland Avenue, MC9006, Chicago, Illinois 60637 (United States)

    2012-05-15

    Purpose: Dose accuracy has been shown to vary with dose per segment and dose rate when delivered with static multileaf collimator (SMLC) intensity modulated radiation therapy (IMRT) by Varian C-series MLC controllers. The authors investigated the impact of monitor units (MUs) per segment and dose rate on the dose delivery accuracy of SMLC-IMRT fields on a Varian TrueBeam linear accelerator (LINAC), which delivers dose and manages motion of all components using a single integrated controller. Methods: An SMLC sequence was created consisting of ten identical 10 x 10 cm{sup 2} segments with identical MUs. Beam holding between segments was achieved by moving one out-of-field MLC leaf pair. Measurements were repeated for various combinations of MU/segment ranging from 1 to 40 and dose rates of 100-600 MU/min for a 6 MV photon beam (6X) and dose rates of 800-2400 MU/min for a 10 MV flattening-filter free photon (10XFFF) beam. All measurements were made with a Farmer (0.6 cm{sup 3}) ionization chamber placed at the isocenter in a solid-water phantom at 10 cm depth. The measurements were performed on two Varian LINACs: C-series Trilogy and TrueBeam. Each sequence was delivered three times and the dose readings for the corresponding segments were averaged. The effects of MU/segment, dose rate, and LINAC type on the relative dose variation ({Delta}{sub i}) were compared using F-tests ({alpha} = 0.05). Results: On the Trilogy, large {Delta}{sub i} was observed in small MU segments: at 1 MU/segment, the maximum {Delta}{sub i} was 10.1% and 57.9% at 100 MU/min and 600 MU/min, respectively. Also, the first segment of each sequence consistently overshot ({Delta}{sub i} > 0), while the last segment consistently undershot ({Delta}{sub i} < 0). On the TrueBeam, at 1 MU/segment, {Delta}{sub i} ranged from 3.0% to 4.5% at 100 and 600 MU/min; no obvious overshoot/undershoot trend was observed. F-tests showed statistically significant difference [(1 - {beta}) =1.0000] between the

  10. 介质壁直线加速器加速单元间的电路耦合及解耦%Circuit coupling and decoupling between accelerating units of dielectric wall linear accelerator

    Institute of Scientific and Technical Information of China (English)

    谌怡; 张篁; 刘毅; 王卫; 叶茂; 夏连胜; 石金水; 章林文; 邓建军

    2016-01-01

    中国工程物理研究院流体物理研究所研发的介质壁直线加速器是基于固态脉冲形成线、GaAs光导开关和高梯度绝缘介质壁三项关键技术的新型直线脉冲加速器.在加速器调试阶段,测量出获得加速的质子束流能量远低于预期值,在排除功率源负载能力因素之后,发现脉冲功率源因连接回路引起的电路耦合效应是导致束流能量低的主要原因.基于介质壁直线加速器加速单元放电回路结构的分析,确认了加速单元之间的电路耦合的必然性.并通过测量回路电流,研究了几种不同工作模式下的电路耦合效应.结合电路耦合的特点,给出了两种基于磁芯隔离的解耦方法,并测量了这两种方法的解耦效率.%The dielectric wall linear accelerator,based on technologies of solid-state pulse forming lines,photoconductive semiconductor switches and high gradient insulators,is a new concept linear accelerator being developed at Institute of Fluid Phys-ics,CAEP.During accelerator test process,the measured energy gain of the accelerated proton beam is much lower than expec-ted.After the exclusion of the pulsed power source factor,we find that the coupling effect induced connecting circuit is the main factor of causing low beam energy gain.Based on discharge circuit analysis of the dielectric wall linear accelerator acceleration u-nit,we confirm that the circuit coupling between acceleration units is inevitable.The circuit coupling of several different operation modes is studied by measuring the circuit current.According to the characteristics of the coupled circuit,we give two kind of de-coupling methods based on the magnetic core isolation,and we measure the efficiency of the decoupling of the two methods.

  11. Quantitative analysis of results of quality control tests in linear accelerators used in radiotherapy; Analise quantitativa dos resultados de testes de controle de qualidade em aceleradores lineares usados em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Passaro, Bruno M.; Rodrigues, Laura N. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Videira, Heber S., E-mail: bruno.passaro@gmail.com [Universidade de Sao Paulo (HCFMRP/USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas

    2013-04-15

    The aim of this study is to assess and analyze the stability of the calibration factor of three linear accelerators, as well as the other dosimetric parameters normally included in a program of quality control in radiotherapy. The average calibration factors of the accelerators for the period of approximately four years for the Clinac 600C and Clinac 6EX were (0.998±0.012) and (0.996±0.014), respectively. For the Clinac 2100CD 6 MV and 15 MV was (1.008±0.009) and (1.006±0.010), respectively, in a period of approximately four years. The data of the calibration factors were divided into four subgroups for a more detailed analysis of behavior over the years. Through statistical analysis of calibration factors, we found that for the 600C and Clinacs 2100CD, is an expected probability that more than 90% of cases the values are within acceptable ranges according to TG-142, while for the Clinac 6EX is expected around 85% since this had several exchanges of accelerator components. The values of TPR20,10 of three accelerators are practically constant and within acceptable limits according to the TG-142. It can be concluded that a detailed study of data from the calibration factor of the accelerators and TPR{sub 20},{sub 10} from a quantitative point of view, is extremely useful in a quality assurance program. (author)

  12. Poster — Thur Eve — 46: Monte Carlo model of the Novalis Classic 6MV stereotactic linear accelerator using the GATE simulation platform

    Energy Technology Data Exchange (ETDEWEB)

    Wiebe, J [Department of Medical Physics, Tom Baker Cancer Centre, Calgary AB (Canada); Department of Physics and Astronomy, University of Calgary, Calgary, AB (Canada); Ploquin, N [Department of Medical Physics, Tom Baker Cancer Centre, Calgary AB (Canada); Department of Physics and Astronomy, University of Calgary, Calgary, AB (Canada); Department of Oncology, University of Calgary, Calgary, AB (Canada)

    2014-08-15

    Monte Carlo (MC) simulation is accepted as the most accurate method to predict dose deposition when compared to other methods in radiation treatment planning. Current dose calculation algorithms used for treatment planning can become inaccurate when small radiation fields and tissue inhomogeneities are present. At our centre the Novalis Classic linear accelerator (linac) is used for Stereotactic Radiosurgery (SRS). The first MC model to date of the Novalis Classic linac was developed at our centre using the Geant4 Application for Tomographic Emission (GATE) simulation platform. GATE is relatively new, open source MC software built from CERN's Geometry and Tracking 4 (Geant4) toolkit. The linac geometry was modeled using manufacturer specifications, as well as in-house measurements of the micro MLC's. Among multiple model parameters, the initial electron beam was adjusted so that calculated depth dose curves agreed with measured values. Simulations were run on the European Grid Infrastructure through GateLab. Simulation time is approximately 8 hours on GateLab for a complete head model simulation to acquire a phase space file. Current results have a majority of points within 3% of the measured dose values for square field sizes ranging from 6×6 mm{sup 2} to 98×98 mm{sup 2} (maximum field size on the Novalis Classic linac) at 100 cm SSD. The x-ray spectrum was determined from the MC data as well. The model provides an investigation into GATE'S capabilities and has the potential to be used as a research tool and an independent dose calculation engine for clinical treatment plans.

  13. Evaluation of area monitor response for neutrons in radiation field generated by a 15 MV clinic accelerator; Avaliacao da resposta dos monitores de area para neutrons em campo de radiacao gerado por um acelerador clinico de 15 MV

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, Ana Paula

    2011-07-01

    The clinical importance and usage of linear accelerators in cancer treatment increased significantly in the last years. Coupled with this growth came the concern about the use of accelerators with energies over to 10 MeV which produce therapeutic beam contaminated with neutrons generated when high-energy photons interact with high-atomic-number materials such as tungsten and lead present in the accelerator itself. At these facilities, measurements of the ambient dose equivalent for neutrons present difficulties owing to the existence of a mixed radiation field and possible electromagnetic interference near the accelerator. The Neutron Laboratory of the IRD - Brazilian Institute for Radioprotection and Dosimetry, aiming to evaluate the survey meters performance at these facilities, initiated studies of instrumentation response in the presence of different neutron spectra. Neutrons sources with average energies ranging from 0.55 to 4.2 MeV, four different survey meters and one ionization chamber to obtain the ratio between the dose due to neutrons and gamma radiation were used in this work. The evaluation of these measurements, performed in a 15 MV linear accelerator room is presented. This work presents results that demonstrate the complexity and care needed to make neutrons measurements in radiotherapy treatment rooms containing high energy clinical accelerators. (author)

  14. THE METHOD OF DETERMINATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 3. The dependence of the radiation beam characteristics

    Directory of Open Access Journals (Sweden)

    E. V. Titovich

    2016-01-01

    Full Text Available To ensure the radiation protection of oncology patients is needed to provide the constancy of functional characteristics of the medical linear accelerators, which affect the accuracy of dose delivery. For this purpose, their quality control procedures are realized including calibration of radiation output of the linac, so the error in determining the dose reference value during this procedure must not exceed 2 %. The aim is to develop a methodology for determining the error in determining this value, depending on the characteristics of the radiation beam. Dosimetric measurements of Trilogy S/N 3567 linac dose distributions have been carried out for achievement of the objectives, on the basis of which dose errors depending on the dose rate value, the accuracy of the beam quality and output factors determination, the symmetry and uniformity of the radiation field, the angular dependence of the linac radiation output were obtained. It was found that the greatest impact on the value of the error has the error in the output factors determination (up to 5.26 % for both photon energy. Dose errors caused by changing dose rate during treatment were different for two photon energies, and reached 1.6 % for 6 MeV and 1.4 % for 18 MeV. Dose errors caused by inaccuracies of the beam quality determination were different for two photon energies, and reached 1.1 % for 18 MeV and –0.3 % for 6 MeV. Errors caused by the remaining of the characteristic do not exceed 1 %. Thus, there is a possibility to express the results of periodic quality control of the linear accelerator in terms of dose and use them to conduct a comprehensive assessment of the possibility of clinical use of a linear accelerator for oncology patients irradiation on the basis of the calibration of radiation output.

  15. A Symmetrical Linear Acceleration and Deceleration Control Method%一种对称式直线加减速方法

    Institute of Scientific and Technical Information of China (English)

    黄昭县; 王志成

    2014-01-01

    在高速高精加工中,定位时间和定位精度是衡量数控系统性能的两项重要指标。论文分析了传统直线加减速中定位时间较长的原因,在此基础上提出了采用对称思想使减速段与加速段严格对称的改进方法,并进行了仿真和实验。结果表明在保证精度的前提下,采用该方法可以缩短定位时间,能够提高定位效率。%In high-speed and high-precision processing industry, the positioning time and positioning accura-cy are the most important indicators in measured the performance of CNC machine tools . The reasons of po-sitioning time longer in the traditional linear acceleration and deceleration control is analyzed. On this basis, it puts forward an improved linear acceleration and deceleration control methods whose deceleration and ac-celeration segments are strictly symmetrical and carries out simulation and experiment. The results show that this method can shorten the positioned time and improve the positioning efficiency under the premise of ensu-ring accuracy.

  16. A novel method for the measurement of linear body segment parameters during clinical gait analysis.

    Science.gov (United States)

    Geil, Mark D

    2013-09-01

    Clinical gait analysis is a valuable tool for the understanding of motion disorders and treatment outcomes. Most standard models used in gait analysis rely on predefined sets of body segment parameters that must be measured on each individual. Traditionally, these parameters are measured using calipers and tape measures. The process can be time consuming and is prone to several sources of error. This investigation explored a novel method for rapid recording of linear body segment parameters using magnetic-field based digital calipers commonly used for a different purpose in prosthetics and orthotics. The digital method was found to be comparable to traditional in all linear measures and data capture was significantly faster with the digital method, with mean time savings for 10 measurements of 2.5 min. Digital calipers only record linear distances, and were less accurate when diameters were used to approximate limb circumferences. Experience in measuring BSPs is important, as an experienced measurer was significantly faster than a graduate student and showed less difference between methods. Comparing measurement of adults vs. children showed greater differences with adults, and some method-dependence. If the hardware is available, digital caliper measurement of linear BSPs is accurate and rapid.

  17. Propagation and stability characteristics of a 500-m-long laser-based fiducial line for high-precision alignment of long-distance linear accelerators.

    Science.gov (United States)

    Suwada, Tsuyoshi; Satoh, Masanori; Telada, Souichi; Minoshima, Kaoru

    2013-09-01

    A laser-based alignment system with a He-Ne laser has been newly developed in order to precisely align accelerator units at the KEKB injector linac. The laser beam was first implemented as a 500-m-long fiducial straight line for alignment measurements. We experimentally investigated the propagation and stability characteristics of the laser beam passing through laser pipes in vacuum. The pointing stability at the last fiducial point was successfully obtained with the transverse displacements of ±40 μm level in one standard deviation by applying a feedback control. This pointing stability corresponds to an angle of ±0.08 μrad. This report contains a detailed description of the experimental investigation for the propagation and stability characteristics of the laser beam in the laser-based alignment system for long-distance linear accelerators.

  18. Comparative study of ion acceleration by linearly polarized laser pulses from optimized targets of solid and near-critical density

    Science.gov (United States)

    Bychenkov, V. Yu; Brantov, A. V.; Govras, E. A.

    2016-03-01

    The results of a 3D optimization study of ion acceleration from ultrathin solid density foils (Brantov et al 2015 Phys. Rev. Spec. Top. Accel. Beams 18 021301) are complemented with an improved analytic model of the directed Coulomb explosion. Similarly to optimizing overdense targets, we also optimize low-density targets to obtain maximum ion energy, motivated by progress in producing a new generation of low-density slab targets whose density can be very homogeneous and as low as the relativistic critical density. Using 3D simulations, we show that for the same laser pulse, the ion energy can be significantly increased with low-density targets. A new acceleration mechanism is responsible for such an increase. This mechanism is described qualitatively, and it explains an advantage of low-density targets for high-energy ion production by lasers.

  19. LIBO accelerates

    CERN Multimedia

    2002-01-01

    The prototype module of LIBO, a linear accelerator project designed for cancer therapy, has passed its first proton-beam acceleration test. In parallel a new version - LIBO-30 - is being developed, which promises to open up even more interesting avenues.

  20. Detection of Adriamycin-DNA adducts by accelerator mass spectrometry at clinically relevant Adriamycin concentrations.

    Science.gov (United States)

    Coldwell, Kate E; Cutts, Suzanne M; Ognibene, Ted J; Henderson, Paul T; Phillips, Don R

    2008-09-01

    Limited sensitivity of existing assays has prevented investigation of whether Adriamycin-DNA adducts are involved in the anti-tumour potential of Adriamycin. Previous detection has achieved a sensitivity of a few Adriamycin-DNA adducts/10(4) bp DNA, but has required the use of supra-clinical drug concentrations. This work sought to measure Adriamycin-DNA adducts at sub-micromolar doses using accelerator mass spectrometry (AMS), a technique with origins in geochemistry for radiocarbon dating. We have used conditions previously validated (by less sensitive decay counting) to extract [(14)C]Adriamycin-DNA adducts from cells and adapted the methodology to AMS detection. Here we show the first direct evidence of Adriamycin-DNA adducts at clinically-relevant Adriamycin concentrations. [(14)C]Adriamycin treatment (25 nM) resulted in 4.4 +/- 1.0 adducts/10(7) bp ( approximately 1300 adducts/cell) in MCF-7 breast cancer cells, representing the best sensitivity and precision reported to date for the covalent binding of Adriamycin to DNA. The exceedingly sensitive nature of AMS has enabled over three orders of magnitude increased sensitivity of Adriamycin-DNA adduct detection and revealed adduct formation within an hour of drug treatment. This method has been shown to be highly reproducible for the measurement of Adriamycin-DNA adducts in tumour cells in culture and can now be applied to the detection of these adducts in human tissues.

  1. Optimising translational oncology in clinical practice: strategies to accelerate progress in drug development.

    Science.gov (United States)

    Stahel, R; Bogaerts, J; Ciardiello, F; de Ruysscher, D; Dubsky, P; Ducreux, M; Finn, S; Laurent-Puig, P; Peters, S; Piccart, M; Smit, E; Sotiriou, C; Tejpar, S; Van Cutsem, E; Tabernero, J

    2015-02-01

    Despite intense efforts, the socioeconomic burden of cancer remains unacceptably high and treatment advances for many common cancers have been limited, suggesting a need for a new approach to drug development. One issue central to this lack of progress is the heterogeneity and genetic complexity of many tumours. This results in considerable variability in therapeutic response and requires knowledge of the molecular profile of the tumour to guide appropriate treatment selection for individual patients. While recent advances in the molecular characterisation of different cancer types have the potential to transform cancer treatment through precision medicine, such an approach presents a major economic challenge for drug development, since novel targeted agents may only be suitable for a small cohort of patients. Identifying the patients who would benefit from individual therapies and recruiting sufficient numbers of patients with particular cancer subtypes into clinical trials is challenging, and will require collaborative efforts from research groups and industry in order to accelerate progress. A number of molecular screening platforms have already been initiated across Europe, and it is hoped that these networks, along with future collaborations, will benefit not only patients but also society through cost reductions as a result of more efficient use of resources. This review discusses how current developments in translational oncology may be applied in clinical practice in the future, assesses current programmes for the molecular characterisation of cancer and describes possible collaborative approaches designed to maximise the benefits of translational science for patients with cancer.

  2. Warfarin accelerates ectopic mineralization in Abcc6(-/-) mice: clinical relevance to pseudoxanthoma elasticum.

    Science.gov (United States)

    Li, Qiaoli; Guo, Haitao; Chou, David W; Harrington, Dominic J; Schurgers, Leon J; Terry, Sharon F; Uitto, Jouni

    2013-04-01

    Pseudoxanthoma elasticum (PXE) is a multisystem ectopic mineralization disorder caused by mutations in the ABCC6 gene. Warfarin, a commonly used anticoagulant, is associated with increased mineralization of the arterial blood vessels and cardiac valves. We hypothesized that warfarin may accelerate ectopic tissue mineralization in PXE, with clinical consequences. To test this hypothesis, we developed a model in which Abcc6(-/-) mice, which recapitulate features of PXE, were fed a diet supplemented with warfarin and vitamin K1. Warfarin action was confirmed by significantly increased serum levels of oxidized vitamin K. For mice placed on a warfarin-containing diet, quantitative chemical and morphometric analyses revealed massive accumulation of mineral deposits in a number of tissues. Mice fed a warfarin-containing diet were also shown to have abundant uncarboxylated form of matrix Gla protein, which allowed progressive tissue mineralization to ensue. To explore the clinical relevance of these findings, 1747 patients with PXE from the approximately 4000 patients in the PXE International database were surveyed about the use of warfarin. Of the 539 respondents, 2.6% reported past or present use of warfarin. Based on the prevalence of PXE (approximately 1:50,000), thousands of patients with PXE worldwide may be at risk for worsening of PXE as a result of warfarin therapy.

  3. Beam dynamics study of a 30 MeV electron linear accelerator to drive a neutron source

    Science.gov (United States)

    Kumar, Sandeep; Yang, Haeryong; Kang, Heung-Sik

    2014-02-01

    An experimental neutron facility based on 32 MeV/18.47 kW electron linac has been studied by means of PARMELA simulation code. Beam dynamics study for a traveling wave constant gradient electron accelerator is carried out to reach the preferential operation parameters (E = 30 MeV, P = 18 kW, dE/E E-gun, pre-buncher, buncher, and 2 accelerating columns. A disk-loaded, on-axis-coupled, 2π/3-mode type accelerating rf cavity is considered for this linac. After numerous optimizations of linac parameters, 32 MeV beam energy is obtained at the end of the linac. As high electron energy is required to produce acceptable neutron flux. The final neutron flux is estimated to be 5 × 1011 n/cm2/s/mA. Future development will be the real design of a 30 MeV electron linac based on S band traveling wave.

  4. Beam dynamics study of a 30 MeV electron linear accelerator to drive a neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sandeep; Yang, Haeryong; Kang, Heung-Sik, E-mail: hskang@postech.ac.kr [Pohang Accelerator Laboratory, San31, Hyoja-dong, Pohang, Gyeongbuk 790-784 (Korea, Republic of)

    2014-02-14

    An experimental neutron facility based on 32 MeV/18.47 kW electron linac has been studied by means of PARMELA simulation code. Beam dynamics study for a traveling wave constant gradient electron accelerator is carried out to reach the preferential operation parameters (E = 30 MeV, P = 18 kW, dE/E < 12.47% for 99% particles). The whole linac comprises mainly E-gun, pre-buncher, buncher, and 2 accelerating columns. A disk-loaded, on-axis-coupled, 2π/3-mode type accelerating rf cavity is considered for this linac. After numerous optimizations of linac parameters, 32 MeV beam energy is obtained at the end of the linac. As high electron energy is required to produce acceptable neutron flux. The final neutron flux is estimated to be 5 × 10{sup 11} n/cm{sup 2}/s/mA. Future development will be the real design of a 30 MeV electron linac based on S band traveling wave.

  5. SIEMENS数字直线加速器的安全系统%The Security System of SIEMENS Digital Linear Accelerator

    Institute of Scientific and Technical Information of China (English)

    王剑平

    2013-01-01

      安全系统在放射治疗中起到保障患者和设备安全的重要作用。该文分析了西门子数字式直线加速器3种安全系统的原理和构成,并实例介绍了它在日常中的应用。%The security system plays an important role to protect the safety of patients and equipments in radiotherapy. The principle and structure of three kinds of security system of the Siemens digital linear accelerator were analyzed with some examples.

  6. Preliminary design report of a relativistic-Klystron two-beam-accelerator based power source for a 1 TeV center-of-mass next linear collider

    Energy Technology Data Exchange (ETDEWEB)

    Yu, S.; Goffeney, N.; Henestroza, E. [Lawrence Berkeley Lab., CA (United States)] [and others

    1995-02-22

    A preliminary point design for an 11.4 GHz power source for a 1 TeV center-of-mass Next Linear Collider (NLC) based on the Relativistic-Klystron Two-Beam-Accelerator (RK-TBA) concept is presented. The present report is the result of a joint LBL-LLNL systems study. consisting of three major thrust areas: physics, engineering, and costing. The new RK-TBA point design, together with our findings in each of these areas, are reported.

  7. Combining rigorous diffraction calculation and GPU accelerated nonsequential raytracing for high precision simulation of a linear grating spectrometer

    Science.gov (United States)

    Mauch, Florian; Fleischle, David; Lyda, Wolfram; Osten, Wolfgang; Krug, Torsten; Häring, Reto

    2011-05-01

    Simulation of grating spectrometers constitutes the problem of propagating a spectrally broad light field through a macroscopic optical system that contains a nanostructured grating surface. The interest of the simulation is to quantify and optimize the stray light behaviour, which is the limiting factor in modern high end spectrometers. In order to accomplish this we present a simulation scheme that combines a RCWA (rigorous coupled wave analysis) simulation of the grating surface with a selfmade GPU (graphics processor unit) accelerated nonsequential raytracer. Using this, we are able to represent the broad spectrum of the light field as a superposition of many monochromatic raysets and handle the huge raynumber in reasonable time.

  8. Implementation of Constant Dose Rate and Constant Angular Spacing Intensity-modulated Arc Therapy for Cervical Cancer by Using a Conventional Linear Accelerator

    Science.gov (United States)

    Zhang, Ruo-Hui; Fan, Xiao-Mei; Bai, Wen-Wen; Cao, Yan-Kun

    2016-01-01

    Background: Volumetric-modulated arc therapy (VMAT) can only be implemented on the new generation linacs such as the Varian Trilogy® and Elekta Synergy®. This prevents most existing linacs from delivering VMAT. The purpose of this study was to investigate the feasibility of using a conventional linear accelerator delivering constant dose rate and constant angular spacing intensity-modulated arc therapy (CDR-CAS-IMAT) for treating cervical cancer. Methods: Twenty patients with cervical cancer previously treated with intensity-modulated radiation therapy (IMRT) using Varian Clinical 23EX were retreated using CDR-CAS-IMAT. The planning target volume (PTV) was set as 50.4 Gy in 28 fractions. Plans were evaluated based on the ability to meet the dose volume histogram. The homogeneity index (HI), target volume conformity index (CI), the dose to organs at risk, radiation delivery time, and monitor units (MUs) were also compared. The paired t-test was used to analyze the two data sets. All statistical analyses were performed using SPSS 19.0 software. Results: Compared to the IMRT group, the CDR-CAS-IMAT group showed better PTV CI (0.85 ± 0.03 vs. 0.81 ± 0.03, P = 0.001), clinical target volume CI (0.46 ± 0.05 vs. 0.43 ± 0.05, P = 0.001), HI (0.09±0.02 vs. 0.11 ± 0.02, P = 0.005) and D95 (5196.33 ± 28.24 cGy vs. 5162.63 ± 31.12 cGy, P = 0.000), and cord D2 (3743.8 ± 118.7 cGy vs. 3806.2 ± 98.7 cGy, P = 0.017) and rectum V40 (41.9 ± 6.1% vs. 44.2 ± 4.8%, P = 0.026). Treatment time (422.7 ± 46.7 s vs. 84.6 ± 7.8 s, P = 0.000) and the total plan Mus (927.4 ± 79.1 vs. 787.5 ± 78.5, P = 0.000) decreased by a factor of 0.8 and 0.15, respectively. The IMRT group plans were superior to the CDR-CAS-IMAT group plans considering decreasing bladder V50 (17.4 ± 4.5% vs. 16.6 ± 4.2%, P = 0.049), bowel V30 (39.6 ± 6.5% vs. 36.6 ± 7.5%, P = 0.008), and low-dose irradiation volume; there were no significant differences in other statistical indexes. Conclusions

  9. Implementation of Constant Dose Rate and Constant Angular Spacing Intensity-modulated Arc Therapy for Cervical Cancer by Using a Conventional Linear Accelerator

    Institute of Scientific and Technical Information of China (English)

    Ruo-Hui Zhang; Xiao-Mei Fan; Wen-Wen Bai; Yan-Kun Cao

    2016-01-01

    Background: Volumetric-modulated arc therapy (VMAT) can only be implemented on the new generation linacs such as the Varian Trilogy(R) and Elekta Synergy(R).This prevents most existing linacs from delivering VMAT.The purpose of this study was to investigate the feasibility of using a conventional linear accelerator delivering constant dose rate and constant angular spacing intensity-modulated arc therapy (CDR-CAS-IMAT) for treating cervical cancer.Methods: Twenty patients with cervical cancer previously treated with intensity-modulated radiation therapy (IMRT) using Varian Clinical 23EX were retreated using CDR-CAS-IMAT.The planning target volume (PTV) was set as 50.4 Gy in 28 fractions.Plans were evaluated based on the ability to meet the dose volume histogram.The homogeneity index (HI), target volume conformity index (CI), the dose to organs at risk, radiation delivery time, and monitor units (MUs) were also compared.The paired t-test was used to analyze the two data sets.All statistical analyses were performed using SPSS 19.0 software.Results: Compared to the IMRT group, the CDR-CAS-IMAT group showed better PTV CI (0.85 ± 0.03 vs.0.81 ± 0.03, P =0.001), clinical target volume CI (0.46 ± 0.05 vs.0.43 ± 0.05, P =0.001), HI (0.09±0.02 vs.0.11 ± 0.02, P =0.005) and D95 (5196.33 ± 28.24 cGy vs.5162.63 ± 31.12 cGy, P =0.000), and cord D2 (3743.8 ± 118.7 cGy vs.3806.2 ± 98.7 cGy, P =0.017) and rectum V40 (41.9 ± 6.1% vs.44.2 ± 4.8%, P =0.026).Treatment time (422.7 ± 46.7 s vs.84.6 ± 7.8 s, P =0.000) and the total plan Mus (927.4 ± 79.1 vs.787.5 ± 78.5, P =0.000) decreased by a factor of 0.8 and 0.15, respectively.The IMRT group plans were superior to the CDR-CAS-IMAT group plans considering decreasing bladder V50 (17.4 ± 4.5% vs.16.6 ± 4.2%, P =0.049), bowel V30 (39.6 ± 6.5% vs.36.6 ± 7.5%, P =0.008), and low-dose irradiation volume;there were no significant differences in other statistical indexes.Conclusions: Patients with cervical

  10. Shielding evaluation of a medical linear accelerator vault in preparation for installing a high-dose rate 252Cf remote afterloader.

    Science.gov (United States)

    Melhus, C S; Rivard, M J; Kurkomelis, J; Liddle, C B; Massé, F X

    2005-01-01

    In support of the effort to begin high-dose rate 252Cf brachytherapy treatments at Tufts-New England Medical Center, the shielding capabilities of a clinical accelerator vault against the neutron and photon emissions from a 1.124 mg 252Cf source were examined. Outside the clinical accelerator vault, the fast neutron dose equivalent rate was below the lower limit of detection of a CR-39 etched track detector and below 0.14 +/- 0.02 muSv h(-1) with a proportional counter, which is consistent, within the uncertainties, with natural background. The photon dose equivalent rate was also measured to be below background levels (0.1 muSv h(-1)) using an ionisation chamber and an optically stimulated luminescence dosemeter. A Monte Carlo simulation of neutron transport through the accelerator vault was performed to validate measured values and determine the thermal-energy to low-energy neutron component. Monte Carlo results showed that the dose equivalent rate from fast neutrons was reduced by a factor of 100,000 after attenuation through the vault wall, and the thermal-energy neutron dose equivalent rate would be an additional factor of 1000 below that of the fast neutrons. Based on these findings, the shielding installed in this facility is sufficient for the use of at least 5.0 mg of 252Cf.

  11. Measurement of back-scattered radiation from micro multileaf collimator into the beam monitor chamber from a dual energy linear accelerator

    Directory of Open Access Journals (Sweden)

    Muralidhar K

    2007-01-01

    Full Text Available Measurements designed to find the collimator backscatter into the beam monitor chamber from Micro Multileaf collimator of 6 MV photon beams of the Siemens Primus linear accelerator were made with the help of dose rate feedback control. The photons and electrons backscattered from the upper and lower secondary collimator jaws give rise to a significant increase in the ion charge measured by monitor chamber. This increase varies between the different accelerators. The output measurements were carried out in air at the isocenter. The effect of collimator backscatter was investigated by measuring the pulse width, number of beam pulses per monitor unit, monitor unit rate and dose for different mMLC openings. These measurements were made with and without dose rate feedback control, i.e., with constant electron beam current in the accelerator. Monitor unit rate (MU/min was almost constant for all field sizes. The maximum variation between the open and the closed feedback control circuits was 2.5%. There was no difference in pulse width and negligible difference in pulse frequency. Maximum value of backscattered radiation from the micro Multileaf collimator into the beam monitor chamber was found to be 0.5%.

  12. High power operation of the polyphase resonant converter modulator system for the spallation neutron source linear accelerator

    CERN Document Server

    Reass, W A; Baca, D M; Doss, J D; Gonzáles, J M; Gribble, R F; Trujillo, P G

    2003-01-01

    The spallation neutron source (SNS) is a new 1.4 MW average power beam, 1 GeV accelerator being built at Oak Ridge national laboratory. The accelerator requires 15 "long-pulse" converter-modulator stations each providing a maximum of 11 MW pulses with a 1.1 MW average power. Two variants of the converter-modulator are utilized, an 80 kV and a 140 kV design, the voltage dependant on the type of klystron load. The converter-modulator can be described as a resonant zero-voltage- switching polyphase boost inverter. As noted in Figure 1, each converter modulator derives its buss voltage from a standard 13.8 kV to 2100 Y (1.5 MVA) substation cast-core transformer. The substation also contains harmonic traps and filters to accommodate IEEE 519 and 141 regulations. Each substation is followed by an SCR preregulator to accommodate system voltage changes from no load to full load, in addition to providing a soft-start function. Energy storage and filtering is provided by special low inductance self-clearing metallized ...

  13. Scalability of the LEU-Modified Cintichem Process: 3-MeV Van de Graaff and 35-MeV Electron Linear Accelerator Studies

    Energy Technology Data Exchange (ETDEWEB)

    Rotsch, David A. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Brossard, Tom [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Roussin, Ethan [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Quigley, Kevin [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Chemerisov, Sergey [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Gromov, Roman [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Jonah, Charles [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Hafenrichter, Lohman [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Tkac, Peter [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Krebs, John [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Vandegrift, George F. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division

    2016-10-31

    Molybdenum-99, the mother of Tc-99m, can be produced from fission of U-235 in nuclear reactors and purified from fission products by the Cintichem process, later modified for low-enriched uranium (LEU) targets. The key step in this process is the precipitation of Mo with α-benzoin oxime (ABO). The stability of this complex to radiation has been examined. Molybdenum-ABO was irradiated with 3 MeV electrons produced by a Van de Graaff generator and 35 MeV electrons produced by a 50 MeV/25 kW electron linear accelerator. Dose equivalents of 1.7–31.2 kCi of Mo-99 were administered to freshly prepared Mo-ABO. Irradiated samples of Mo-ABO were processed according to the LEU Modified-Cintichem process. The Van de Graaff data indicated good radiation stability of the Mo-ABO complex up to ~15 kCi dose equivalents of Mo-99 and nearly complete destruction at doses >24 kCi Mo-99. The linear accelerator data indicate that even at 6.2 kCi of Mo-99 equivalence of dose, the sample lost ~20% of Mo-99. The 20% loss of Mo-99 at this low dose may be attributed to thermal decomposition of the product from the heat deposited in the sample during irradiation.

  14. Accelerated variant of idiopathic pulmonary fibrosis: clinical behavior and gene expression pattern.

    Directory of Open Access Journals (Sweden)

    Moisés Selman

    Full Text Available BACKGROUND: Idiopathic pulmonary fibrosis (IPF is characterized by the insidious onset of dyspnea or cough. However, a subset of patients has a short duration of symptoms with rapid progression to end-stage disease. In this study, we evaluated clinical and molecular features of "rapid" and "slow" progressors with IPF. METHODS AND FINDINGS: 26 patients with 24 months of symptoms [slow progressors] were studied. Survival was analyzed by the Kaplan-Meyer method and proportional hazard's model. Lung microarrays and tissue proteins were measured in a subset of patients. No differences were found in age, physiologic impairment and bronchoalveolar lavage (BAL cellular profile. There were more males (OR = 6.5; CI:1.4-29.5; p = 0.006 and smokers (OR = 3.04; CI:1.1-8.3; p = 0.04 in the rapid progressors group. Survival from the beginning of symptoms was significantly reduced in rapid progressors (HR = 9.0; CI:4.48-18.3; p2-fold increase of active matrix metalloproteinase-9, and induced a higher fibroblast migration compared with slow progressors and controls [238+/-98% versus 123+/-29% (p<0.05 and 30+/-17% (p<0.01]. CONCLUSIONS/SIGNIFICANCE: A subgroup of IPF patients, predominantly smoking males, display an accelerated clinical course and have a gene expression pattern that is different from those with slower progression and longer survival. These findings highlight the variability in the progression of IPF, and may explain, in part, the difficulty in obtaining significant and reproducible results in studies of therapeutic interventions in patients with IPF.

  15. Clinical and Histologic Evaluation of Platelet-Rich Fibrin Accelerated Epithelization of Gingival Wound

    Science.gov (United States)

    Bansal, Mansi; Kumar, Ashish; Puri, Komal; Khatri, Manish; Gupta, Geeti; Vij, Hitesh

    2016-01-01

    The foremost indication for gingival depigmentation is patient demand for improved aesthetics. In most cases after the removal of pigmented layer, the area is covered with periodontal packs. These dressings have no curative properties. They only minimise the likelihood of surface trauma during mastication. However, platelet-rich fibrin (PRF) accelerates wound healing by effective neovascularisation and promoting fast cicatricial tissue remodelling. In the present split mouth study, PRF membrane was applied in the first quadrant and non-eugenol dressing (Coe-Pack) in the second quadrant after depigmentation. Clinical evaluation of epithelization with toluidine blue revealed that PRF treated sites stained substantially less indicating better wound healing as compared to Coe-Pack sites, which appeared more erythematous after 5 days. The histologic evaluation also revealed greater inflammatory cell infiltrate on Coe-Pack sites as compared to PRF. Thus, PRF membrane as a periodontal dressing is a successful approach to protect the raw wound area of the depigmented site to reduce healing time and patient discomfort.

  16. Clinical and histologic evaluation of platelet-rich fibrin accelerated epithelization of gingival wound

    Directory of Open Access Journals (Sweden)

    Mansi Bansal

    2016-01-01

    Full Text Available The foremost indication for gingival depigmentation is patient demand for improved aesthetics. In most cases after the removal of pigmented layer, the area is covered with periodontal packs. These dressings have no curative properties. They only minimise the likelihood of surface trauma during mastication. However, platelet-rich fibrin (PRF accelerates wound healing by effective neovascularisation and promoting fast cicatricial tissue remodelling. In the present split mouth study, PRF membrane was applied in the first quadrant and non-eugenol dressing (Coe-Pack in the second quadrant after depigmentation. Clinical evaluation of epithelization with toluidine blue revealed that PRF treated sites stained substantially less indicating better wound healing as compared to Coe-Pack sites, which appeared more erythematous after 5 days. The histologic evaluation also revealed greater inflammatory cell infiltrate on Coe-Pack sites as compared to PRF. Thus, PRF membrane as a periodontal dressing is a successful approach to protect the raw wound area of the depigmented site to reduce healing time and patient discomfort.

  17. Finite element analysis and frequency shift studies for the bridge coupler of the coupled cavity linear accelerator of the spallation neutron source.

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Z. (Zukun)

    2001-01-01

    The Spallation Neutron Source (SNS) is an accelerator-based neutron scattering research facility. The linear accelerator (linac) is the principal accelerating structure and divided into a room-temperature linac and a superconducting linac. The normal conducting linac system that consists of a Drift Tube Linac (DTL) and a Coupled Cavity Linac (CCL) is to be built by Los Alamos National Laboratory. The CCL structure is 55.36-meters long. It accelerates H- beam from 86.8 Mev to 185.6 Mev at operating frequency of 805 MHz. This side coupled cavity structure has 8 cells per segment, 12 segments and 11 bridge couplers per module, and 4 modules total. A 5-MW klystron powers each module. The number 3 and number 9 bridge coupler of each module are connected to the 5-MW RF power supply. The bridge coupler with length of 2.5 {beta}{gamma} is a three-cell structure and located between the segments and allows power flow through the module. The center cell of each bridge coupler is excited during normal operation. To obtain a uniform electromagnetic filed and meet the resonant frequency shift, the RF induced heat must be removed. Thus, the thermal deformation and frequency shift studies are performed via numerical simulations in order to have an appropriate cooling design and predict the frequency shift under operation. The center cell of the bridge coupler also contains a large 4-inch slug tuner and a tuning post that used to provide bulk frequency adjustment and field intensity adjustment, so that produce the proper total field distribution in the module assembly.

  18. Quality control of virtual wedge in a linear electron accelerator with a computerized radiography system (CR); Control de calidad de la cuna virtual en un acelerador lineal de electrones mediante un sistema de radiografia competerizada (CR)

    Energy Technology Data Exchange (ETDEWEB)

    Ordiales, J. M.; Alvarez, F. J.; Falero, B.

    2011-07-01

    For quality control of the virtual wedge there are several systems on the market as arrays of detectors or ionization chambers, linear or 2D configuration, radiochromic films or digital imaging systems incorporated in electron linear accelerators (ALE ). The present work aims at implementing a system of Computed Radiography (CR) for a routine check of the virtual wedge.

  19. Interventional multispectral photoacoustic imaging with a clinical linear array ultrasound probe for guiding nerve blocks

    Science.gov (United States)

    Xia, Wenfeng; West, Simeon J.; Nikitichev, Daniil I.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.

    2016-03-01

    Accurate identification of tissue structures such as nerves and blood vessels is critically important for interventional procedures such as nerve blocks. Ultrasound imaging is widely used as a guidance modality to visualize anatomical structures in real-time. However, identification of nerves and small blood vessels can be very challenging, and accidental intra-neural or intra-vascular injections can result in significant complications. Multi-spectral photoacoustic imaging can provide high sensitivity and specificity for discriminating hemoglobin- and lipid-rich tissues. However, conventional surface-illumination-based photoacoustic systems suffer from limited sensitivity at large depths. In this study, for the first time, an interventional multispectral photoacoustic imaging (IMPA) system was used to image nerves in a swine model in vivo. Pulsed excitation light with wavelengths in the ranges of 750 - 900 nm and 1150 - 1300 nm was delivered inside the body through an optical fiber positioned within the cannula of an injection needle. Ultrasound waves were received at the tissue surface using a clinical linear array imaging probe. Co-registered B-mode ultrasound images were acquired using the same imaging probe. Nerve identification was performed using a combination of B-mode ultrasound imaging and electrical stimulation. Using a linear model, spectral-unmixing of the photoacoustic data was performed to provide image contrast for oxygenated and de-oxygenated hemoglobin, water and lipids. Good correspondence between a known nerve location and a lipid-rich region in the photoacoustic images was observed. The results indicate that IMPA is a promising modality for guiding nerve blocks and other interventional procedures. Challenges involved with clinical translation are discussed.

  20. Thermal neutron fluence in a treatment room with a Varian linear accelerator at a medical university hospital

    Science.gov (United States)

    Liu, Wen-Shan; Changlai, Sheng-Pin; Pan, Lung-Kwang; Tseng, Hsien-Chun; Chen, Chien-Yi

    2011-09-01

    The indium foil activation technique has been employed to measure thermal neutron fluences ( Φth) among various locations in the treatment room with a 20×20 cm 2 field size and a 15 and 10 MV X-ray beam. Spatial Φth are visualized using colored three-dimensional graphical representations; intensities are up to (1.97±0.13)×10 5 and (1.46±0.13)×10 4 n cm -2/Gy-X at isocenter, respectively. The Φth is found to increase with the X-ray energy of the LINAC and decreases as it moves away from the beam center. However, thermal neutron exposure is not assessed in routine dosimetry planning and radiation assessment of patients since neutron dose contributes <1% of the given therapy dose. However, unlike the accelerated beam limited within the gantry window, photoneutrons are widely spread in the treatment room. Distributions of Φth were measured in water phantom irradiated with 15 MV X-ray beams. The shielding effect of the maze was also evaluated. The experimentally estimated Φth along the maze distance was fitted explicate and the tenth-value layer (TVL) was calculated and discussed. Use of a 10 cm-thick polyethylene door placed at the maze was suitable for radiation shielding.

  1. Microphthalmia with linear skin defects (MLS) syndrome: Clinical, cytogenetic, and molecular characterization

    Energy Technology Data Exchange (ETDEWEB)

    Lindsay, E.A.; Grillo, A.; Ferrero, G.B.; Baldini, A.; Ballabio, A.; Zoghbi, H.Y.; Roth, E.J. [Baylor College of Medicine, Houston, TX (United States); Magenis, E.; Grompe, M. [Oregon Health Science Univ., Portland, OR (United States); Hulten, M. [East Birmingham Hospital, Birmingham (United Kingdom)] [and others

    1994-01-15

    The microphthalmia with linear skin defects (MLS) syndrome (MIM309801) is a severe developmental disorder observed in XX individuals with distal Xp segmental monosomy. The phenotype of this syndrome overlaps with that of both Aicardi (MIM 305050) and Goltz (MIM 305600) syndromes, two X-linked dominant, male-lethal disorders. Here the authors report the clinical, cytogenetic, and molecular characterization of 3 patients with this syndrome. Two of these patients are females with a terminal Xpter-p22.2 deletion. One of these 2 patients had an aborted fetus with anencephaly and the same chromosome abnormality. The third patient is an XX male with Xp/Yp exchange spanning the SRY gene which results in distal Xp monosomy. The extensive clinical variability observed in these patients and the results of the molecular analysis suggest that X-inactivation plays an important role in determining the phenotype of the MLS syndrome. The authors propose that the MLS, Aicardi, and Goltz syndromes are due to the involvement of the same gene(s), and that different patterns of X-inactivation are responsible for the phenotypic differences observed in these 3 disorders. However, they cannot rule out that each component of the MLS phenotype is caused by deletion of a different gene (a contiguous gene syndrome). 24 refs., 4 figs., 1 tab.

  2. Linear Psoriasis

    Directory of Open Access Journals (Sweden)

    Agarwalla Arun

    2001-01-01

    Full Text Available Linear psoriasis, inflammatory linear varrucous epidermal naevus (ILVEN. Lichen straitus, linear lichen planus and invasion of epidermal naevi by psoriasis have clinical and histopathological overlap. We report two young male patients of true linear psoriasis without classical lesions elsewhere which were proved histopathologically. Seasonal variation and good response to topical antipsoriatic treatment supported the diagnosis.

  3. Commissioning and quality assurance of the X-ray volume Imaging system of an image-guided radiotherapy capable linear accelerator

    Directory of Open Access Journals (Sweden)

    Muralidhar K

    2008-01-01

    Full Text Available An Image-Guided Radiotherapy-capable linear accelerator (Elekta Synergy was installed at our hospital, which is equipped with a kV x-ray volume imaging (XVI system and electronic portal imaging device (iViewGT. The objective of this presentation is to describe the results of commissioning measurements carried out on the XVI facility to verify the manufacturer′s specifications and also to evolve a QA schedule which can be used to test its performance routinely. The QA program consists of a series of tests (safety features, geometric accuracy, and image quality. These tests were found to be useful to assess the performance of the XVI system and also proved that XVI system is very suitable for image-guided high-precision radiation therapy.

  4. Commissioning and quality assurance of the X-ray volume Imaging system of an image-guided radiotherapy capable linear accelerator

    Science.gov (United States)

    Muralidhar, K. R.; Murthy, P. Narayana; Kumar, Rajneesh

    2008-01-01

    An Image-Guided Radiotherapy–capable linear accelerator (Elekta Synergy) was installed at our hospital, which is equipped with a kV x-ray volume imaging (XVI) system and electronic portal imaging device (iViewGT). The objective of this presentation is to describe the results of commissioning measurements carried out on the XVI facility to verify the manufacturer's specifications and also to evolve a QA schedule which can be used to test its performance routinely. The QA program consists of a series of tests (safety features, geometric accuracy, and image quality). These tests were found to be useful to assess the performance of the XVI system and also proved that XVI system is very suitable for image-guided high-precision radiation therapy. PMID:19893694

  5. Construction of. gamma pi. /sup 0/ spectrometer and photon tagging facility at Bates Linear Accelerator. Final report, July 31, 1979-July 31, 1980

    Energy Technology Data Exchange (ETDEWEB)

    Booth, E.C.

    1981-08-01

    The funds provided under Contract No. DE-AC02-79ER10486 were totally expended for hardware and supplies required by two related devices at the Bates Linear Accelerator. These were a photon tagging facility and a ..gamma pi../sup 0/ spectrometer in Beam Line C of the new South Experimental Hall. Construction was begun in November of 1979 and both systems became fully operational in the summer of 1981. Preliminary data was taken in 1980 with a prototype ..gamma pi../sup 0/ spectrometer will be carried out in the fall of 1981 and spring of 1982. The photon tagging system has been used successfully to calibrate the ..gamma pi../sup 0/ spectrometer for the BU - MIT collaboration and to test a lead glass detector system for Brandeis University.

  6. Dosimetry of the stereotactic radiosurgery with linear accelerators equipped with micro multi-blades collimators; Dosimetria dos sistemas de radiocirurgia estereotaxica com aceleradores lineares equipados com colimadores micro multi-laminas

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Andre Mozart de Miranda

    2008-07-01

    In this work, absorbed dose to water produced by the radiation beam of a clinical linear accelerator - CLINAC 600C{sup TM} (Varian), with a photon beam of 6 MV, were evaluated both theoretically and experimentally. This determination includes square and circular field configurations, the last one obtained with a micro multi leaf collimator - mMLC m3{sup TM} (Brain Lab). Theoretical evaluation was performed throughout Monte Carlo method. Experimental measurements of Percentage Depth Dose - PDD and derived Tissue Maximum Ratio - TMR curves from CLINAC 600C were validated by comparison with reference values as well as with measurements using different detectors. The results indicate local differences smaller than 5% and average differences smaller than 1,5% for each evaluated field, if they are compared to the previous commissioning values (made in 1999) and to the values of literature. Comparisons of ionization chamber and diode result in an average local difference of -0,6% for PDD measurements, and within 1% for lateral dose profiles, at depth, in the flat region. Diode provides measurements with better spatial resolution. Current output factors of open fields agree with reference values within 1,03% of discrepancy level. Current absorbed dose distributions in water are, now, considered reference values and allow characterization of this CLINAC for patient dose calculation. The photon spectra resulting from simulations with PENELOPE and MCNP codes agree approximately in 80% of the sampled points, in what average energies of (1,6 {+-} 0,3)MeV, with MCNP, and of (1,72 {+-} 0,08)MeV, with PENELOPE, are coincident. The created simple source model of the CLINAC 600C, using the PENELOPE code, allows one to calculate dose distributions in water, for open fields, with discrepancies of the order of {+-} 1,0% in dose and of {+-} 0,1 cm in position, if they are compared to experimental measurements. These values met the initial proposed criteria to validate the simulation

  7. Development and application of compact and on-chip electron linear accelerators for dynamic tracking cancer therapy and DNA damage/repair analysis

    Science.gov (United States)

    Uesaka, M.; Demachi, K.; Fujiwara, T.; Dobashi, K.; Fujisawa, H.; Chhatkuli, R. B.; Tsuda, A.; Tanaka, S.; Matsumura, Y.; Otsuki, S.; Kusano, J.; Yamamoto, M.; Nakamura, N.; Tanabe, E.; Koyama, K.; Yoshida, M.; Fujimori, R.; Yasui, A.

    2015-06-01

    We are developing compact electron linear accelerators (hereafter linac) with high RF (Radio Frequency) frequency (9.3 GHz, wavelength 32.3 mm) of X-band and applying to medicine and non-destructive testing. Especially, potable 950 keV and 3.95 MeV linac X-ray sources have been developed for on-site transmission testing at several industrial plants and civil infrastructures including bridges. 6 MeV linac have been made for pinpoint X-ray dynamic tracking cancer therapy. The length of the accelerating tube is ∼600 mm. The electron beam size at the X-ray target is less than 1 mm and X-ray spot size at the cancer is less than 3 mm. Several hardware and software are under construction for dynamic tracking therapy for moving lung cancer. Moreover, as an ultimate compact linac, we are designing and manufacturing a laser dielectric linac of ∼1 MeV with Yr fiber laser (283 THz, wavelength 1.06 pm). Since the wavelength is 1.06 μm, the length of one accelerating strcture is tens pm and the electron beam size is in sub-micro meter. Since the sizes of cell and nuclear are about 10 and 1 μm, respectively, we plan to use this “On-chip” linac for radiation-induced DNA damage/repair analysis. We are thinking a system where DNA in a nucleus of cell is hit by ∼1 μm electron or X-ray beam and observe its repair by proteins and enzymes in live cells in-situ.

  8. Precise直线加速器电离室的维护和故障排查%Routine maintenance of precise linear accelerator ionization chamber

    Institute of Scientific and Technical Information of China (English)

    汪鹏飞; 张永寿; 宋天一

    2012-01-01

    Precise accelerator linear is generally applied in the major hospitals and plays an important role.Ionization chamber,as the key device-ray dose detection,directly impacts on the therapeutic effect of accelerator.It is important to do the routine maintenance well.%Precise直线加速器广泛应用于各大医院的放疗中心,在医院的放射治疗中属于不可缺少且需频繁检修的医疗设备。电离室是一种高精度放射线辐射剂量检测器件,作为其检测射线辐射剂量的关键器件,其工作性能的好坏直接影响加速器的使用效果和治疗疗效。因此,做好电离室的日常维护和检修工作至关重要。

  9. Performance characterization of siemens primus linear accelerator under small monitor unit and small segments for the implementation of step-and-shoot intensitymodulated radiotherapy

    Directory of Open Access Journals (Sweden)

    Reena P

    2006-01-01

    Full Text Available Implementation of step-and-shoot intensity-modulated radiotherapy (IMRT needs careful understanding of the accelerator start-up characteristic to ensure accurate and precise delivery of radiation dose to patient. The dosimetric characteristic of a Siemens Primus linear accelerator (LA which delivers 6 and 18 MV x-rays at the dose rate of 300 and 500 monitor unit (MU per minutes (min respectively was studied under the condition of small MU ranging from 1 to 100. Dose monitor linearity was studied at different dose calibration parameter (D1_C0 by measuring ionization at 10 cm depth in a solid water phantom using a 0.6 cc ionization chamber. Monitor unit stability was studied from different intensity modulated (IM groups comprising various combinations of MU per field and number of fields. Stability of beam flatness and symmetry was investigated under normal and IMRT mode for 20x20 cm2 field under small MU using a 2D Profiler kept isocentrically at 5 cm depth. Inter segment response was investigated form 1 to 10 MU by measuring the dose per MU from various IM groups, each consisting of four segments with inter-segment separation of 2 cm. In the range 1-4 MU, the dose linearity error was more than 5% (max -32% at 1 MU for 6 MV x-rays at factory calibrated D1_C0 value of 6000. The dose linearity error was reduced to -10.95% at 1 MU, within -3% for 2 and 3 MU and ±1% for MU ≥4 when the D1_C0 was subsequently tuned at 4500. For 18 MV x-rays, the dose linearity error at factory calibrated D1_C0 value of 4400 was within ±1% for MU ≥ 3 with maximum of -13.5 observed at 1 MU. For both the beam energies and MU/field ≥ 4, the stability of monitor unit tested for different IM groups was within ±1% of the dose from the normal treatment field. This variation increases to -2.6% for 6 MV and -2.7% for 18 MV x-rays for 2 MU/field. No significant variation was observed in the stability of beam profile measured from normal and IMRT mode. The beam flatness

  10. Tentative Research on Quality Control of Medical Linear Accelerator Using Root Cause Analysis%应用根本原因分析法控制直线加速器医疗质量的尝试

    Institute of Scientific and Technical Information of China (English)

    王振军; 王燕; 刘志成

    2011-01-01

    Objective There are the inevitable risks of the medical devices due to quality problems in the view of clinical engineering. In this paper, the effective methods of the medical device risk control was studied by using the scientific analysis and risk assessment for the medical equipment, as an example with the medical linear accelerator. Methods The Root Cause Analysis (RCA) system was designed and implemented based on the root cause analysis for the quality control of medical devices and the medical linear accelerators were tested by the RCA system. Results The RCA system can reduce the clinical use risk of medical linear accelerators in a large range, and standardize radiation treatment workflow. Conclusion Medical equipment quality control is an important part for protecting quality and safety of health care, and also a new topic of the medical engineering department In the clinical application of the medical devices, the root causes of the risks to the medical devices need to be accurately identified, and then the appropriate and corrective measures need to be developed to effectively reduce the risk of clinical use of medical devices.%目的 从临床工程学角度考虑医疗设备因质量原因或者正常运行中不可避免的风险问题,以医用直线加速器为例,对医疗设备使用风险进行科学分析和评估,研究将医疗设备使用风险控制在可接受的范围内的有效方法.方法 在基于根本原因分析方法促进医疗设备质量控制研究的基础上,设计并实现根本原因分析系统,使用该系统对医用直线加速器进行测试.结果 该系统可以在很大范围内减少医用直线加速器的临床使用风险,规范放射治疗工作流程.结论 医疗设备质量控制是保障医疗质量和安全的重要环节,也是医疗机构中医学工程部门的新课题,在实施中融人根本原因分析技术,高效准确地找出导致医疗设备风险发生的根本

  11. Measurement of photoneutron doses in and out of high-energy X-ray beam of a SATURNE-20 medical linear accelerator by ECE polycarbonate detectors

    CERN Document Server

    Sohrabi, M

    1999-01-01

    Photoneutron contaminations in and out of high energy X-ray beams of the medical linear accelerator SATURNE 20 (CGR) of the Radiotherapy Department of Omeed Hospital in Isfahan, Iran, have been determined using 250 mu m polycarbonate (PC) dosimeters, in strips or in sheets, processed by electrochemical etching (ECE) using specially designed ECE chambers to etch larger sheets. A two dimensional or topographical distribution of neutron contamination was also determined in a full size beam. The neutron dose equivalents (Hn) in the beam of 18 MV X-rays at 80 cm FSD were determined to be linear functions of X-ray dose equivalents (Hx) up to 1400 cSv. The distribution of the Hn at different X-ray doses showed bell-shape profiles with maxima at the isocenter. The ratios of dose equivalents of neutrons to those of X-rays increased as the field size increased having values of 0.22%, 0.28%, 0.31% and 0.37% for field sizes of 10x10, 20x20, 30x30, and 40x40 cm sup 2 respectively. Although such neutron dose equivalents ca...

  12. Purse-String Versus Linear Conventional Skin Wound Closure of an Ileostomy: A Randomized Clinical Trial

    Science.gov (United States)

    Alvandipour, Mina; Gharedaghi, Babak; Khodabakhsh, Hamed

    2016-01-01

    Purpose Infection is one of the most frequent complications that can occur after ileostomy closure. The incidence of wound infection depends on the skin closure technique, but there is no agreement on the perfect closure method for an ileostomy wound. The aim of this study was to evaluate the incidence of infection, the patient's approval, and the patient's pain between purse-string closure (PSC) and the usual linear closure (LC) of a stoma wound. Methods This randomized clinical trial enrolled 66 patients who underwent a stoma closure from February 2015 to May 2015 in Sari Emam Khomeini Hospital. Patients were divided into 2 groups according to the stoma closing method: the PSC group (n = 34) and the LC group (n = 32). The incidences of infection for the 2 groups were compared, and the patients' satisfaction and pain with the stoma were determined by using a questionnaire. Results Infection occurred in 1 of 34 PSC patients (2.9%) and in 7 of 32 LC patients (21.8%), and this difference was statistically significant (P = 0.021). Patients in the PSC group were more satisfied with the resulting wound scar and its cosmetic appearance at one month and three months after surgery (P = 0.043). Conclusion After stoma closure, PSC was associated with a significantly lower incidence of wound infection and greater patient satisfaction compared to LC. However, the healing period for patients who underwent PSC was longer than it was for those who underwent LC. PMID:27626025

  13. Dosimetric properties of radiophotoluminescent glass rod detector in high-energy photon beams from a linear accelerator and cyber-knife.

    Science.gov (United States)

    Arakia, Fujio; Moribe, Nobuyuki; Shimonobou, Toshiaki; Yamashita, Yasuyuki

    2004-07-01

    A fully automatic radiophotoluminescent glass rod dosimeter (GRD) system has recently become commercially available. This article discusses the dosimetric properties of the GRD including uniformity and reproducibility of signal, dose linearity, and energy and directional dependence in high-energy photon beams. In addition, energy response is measured in electron beams. The uniformity and reproducibility of the signal from 50 GRDs using a 60Co beam are both +/- 1.1% (one standard deviation). Good dose linearity of the GRD is maintained for doses ranging from 0.5 to 30 Gy, the lower and upper limits of this study, respectively. The GRD response is found to show little energy dependence in photon energies of a 60Co beam, 4 MV (TPR20(10)=0.617) and 10 MV (TPR(20)10=0.744) x-ray beams. However, the GRD responses for 9 MeV (mean energy, Ez = 3.6 MeV) and 16 MeV (Ez = 10.4 MeV) electron beams are 4%-5% lower than that for a 60Co beam in the beam quality dependence. The measured angular dependence of GRD, ranging from 0 degrees (along the long axis of GRD) to 120 degrees is within 1.5% for a 4 MV x-ray beam. As applications, a linear accelerator-based radiosurgery system and Cyber-Knife output factors are measured by a GRD and compared with those from various detectors including a p-type silicon diode detector, a diamond detector, and an ion chamber. It is found that the GRD is a very useful detector for small field dosimetry, in particular, below 10 mm circular fields.

  14. 将机械式直线加速器用于采油机械的设想%An idea of applying mechanical linear accelerator to oil pumping system

    Institute of Scientific and Technical Information of China (English)

    刘泽峰; 李少果; 黄清世

    2001-01-01

    Mechanical linear accelerator is a new transmission devicedesigned on the basis of the parallel straight push rod linear reducer. To make use of its acceleration and stroke increment functions, an idea of applying the mechanical linear accelerator to oil pumping system is put forward. The design schemes for long stroke pumping unit and downhole stroke increment device both equipped with the mechanical linear accelerator are presented. The long stroke pumping unit with the linear accelerator is easy to realize compound balance and is predicted to have high mechanical efficiency and long service life. The downhole stroke increment device with the linear accelerator can increase the stroke of the subsurface pump plunger, therefore it provides the condition for modifying the existing pumping systems to long stroke pumping systems.%机械式直线加速器是根据平行直动推杆传动机构设计而成的新型传动装置,利用其加速和增程功能,提出两种采取对称布置的直线加速器实现长冲程、低冲次的抽油装置设计新方案:(1)采用直线加速器的长冲程抽油机,其结构合理,便于实现复合平衡,预计有较高的机械效率和较长的使用寿命;(2)采用直线加速器的抽油机井下增程装置,可使地面设备结构紧凑,比同类型长冲程抽油机的悬点载荷相对较低,对现有抽油机实施长冲程改造有着重要的实际意义。

  15. Evaluation of the Acceleration and Deceleration Phase-Rectified Slope to Detect and Improve IUGR Clinical Management

    Directory of Open Access Journals (Sweden)

    Salvatore Tagliaferri

    2015-01-01

    Full Text Available Objective. This study used a new method called Acceleration (or Deceleration Phase-Rectified Slope, APRS (or DPRS to analyze computerized Cardiotocographic (cCTG traces in intrauterine growth restriction (IUGR, in order to calculate acceleration- and deceleration-related fluctuations of the fetal heart rate, and to enhance the prediction of neonatal outcome. Method. Cardiotocograms from a population of 59 healthy and 61 IUGR fetuses from the 30th gestation week matched for gestational age were included. APRS and DPRS analysis was compared to the standard linear and nonlinear cCTG parameters. Statistical analysis was performed through the t-test, ANOVA test, Pearson correlation test and receiver operator characteristic (ROC curves (p<0,05. Results. APRS and DPRS showed high performance to discriminate between Healthy and IUGR fetuses, according to gestational week. A linear correlation with the fetal pH at birth was found in IUGR. The area under the ROC curve was 0.865 for APRS and 0.900 for DPRS before the 34th gestation week. Conclusions. APRS and DPRS could be useful in the identification and management of IUGR fetuses and in the prediction of the neonatal outcome, especially before the 34th week of gestation.

  16. Absence of clinically relevant growth acceleration in untreated children with non-classical congenital adrenal hyperplasia.

    NARCIS (Netherlands)

    Pijnenburg-Kleizen, K.J.; Borm, G.F.; Otten, B.J.; Schott, D.A.; Akker, E.L. van den; Stokvis-Brantsma, W.H.; Voorhoeve, P.G.; Bakker, B.; Claahsen-van der Grinten, H.L.

    2012-01-01

    BACKGROUND/AIMS: In classical congenital adrenal hyperplasia (CAH), elevation of adrenal androgens leads to accelerated growth and bone maturation with compromised adult height. In untreated children with non-classical CAH (NC-CAH), in which adrenal androgens are generally only slightly increased, g

  17. Intraoperative Radiation Therapy in Early Breast Cancer Using a Linear Accelerator Outside of the Operative Suite: An “Image-Guided” Approach

    Energy Technology Data Exchange (ETDEWEB)

    Hanna, Samir Abdallah, E-mail: samir.hanna@hsl.org.br [Department of Radiation Oncology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Simões Dornellas de Barros, Alfredo Carlos; Martins de Andrade, Felipe Eduardo; Barbosa Bevilacqua, Jose Luiz [Department of Mastology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Morales Piato, José Roberto [Department of Mastology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Department of Gynecology, Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo (Brazil); Lopes Pelosi, Edilson [Department of Radiation Oncology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Martella, Eduardo [Department of Radiation Oncology, Hospital Perola Byington, Sao Paulo (Brazil); Fernandes da Silva, João Luis [Department of Radiation Oncology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Andrade Carvalho, Heloisa de [Department of Radiation Oncology, Hospital Sirio-Libanes, Sao Paulo (Brazil); Department of Radiology and Oncology, Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo (Brazil)

    2014-08-01

    Purpose: To present local control, complications, and cosmetic outcomes of intraoperative radiation therapy (IORT) for early breast cancer, as well as technical aspects related to the use of a nondedicated linear accelerator. Methods and Materials: This prospective trial began in May of 2004. Eligibility criteria were biopsy-proven breast-infiltrating ductal carcinoma, age >40 years, tumor <3 cm, and cN0. Exclusion criteria were in situ or lobular types, multicentricity, skin invasion, any contraindication for surgery and/or radiation therapy, sentinel lymph node involvement, metastasis, or another malignancy. Patients underwent classic quadrantectomy with intraoperative sentinel lymph node and margins evaluation. If both free, the patient was transferred from operative suite to linear accelerator room, and IORT was delivered (21 Gy). Primary endpoint: local recurrence (LR); secondary endpoints: toxicities and aesthetics. Quality assurance involved using a customized shield for chest wall protection, applying procedures to minimize infection caused by patient transportation, and using portal films to check collimator-shield alignment. Results: A total of 152 patients were included, with at least 1 year follow-up. Median age (range) was 58.3 (40-85.4) years, and median follow-up time was 50.7 (12-110.5) months. The likelihood of 5-year local recurrence was 3.7%. There were 3 deaths, 2 of which were cancer related. The Kaplan-Meier 5-year actuarial estimates of overall, disease-free, and local recurrence-free survivals were 97.8%, 92.5%, and 96.3%, respectively. The overall incidences of acute and late toxicities were 12.5% and 29.6%, respectively. Excellent, good, fair, and bad cosmetic results were observed in 76.9%, 15.8%, 4.3%, and 2.8% of patients, respectively. Most treatments were performed with a 5-cm collimator, and in 39.8% of the patients the electron-beam energy used was ≥12 MeV. All patients underwent portal film evaluation, and the shielding was

  18. Accelerated echo planar J-resolved spectroscopic imaging in prostate cancer: a pilot validation of non-linear reconstruction using total variation and maximum entropy.

    Science.gov (United States)

    Nagarajan, Rajakumar; Iqbal, Zohaib; Burns, Brian; Wilson, Neil E; Sarma, Manoj K; Margolis, Daniel A; Reiter, Robert E; Raman, Steven S; Thomas, M Albert

    2015-11-01

    The overlap of metabolites is a major limitation in one-dimensional (1D) spectral-based single-voxel MRS and multivoxel-based MRSI. By combining echo planar spectroscopic imaging (EPSI) with a two-dimensional (2D) J-resolved spectroscopic (JPRESS) sequence, 2D spectra can be recorded in multiple locations in a single slice of prostate using four-dimensional (4D) echo planar J-resolved spectroscopic imaging (EP-JRESI). The goal of the present work was to validate two different non-linear reconstruction methods independently using compressed sensing-based 4D EP-JRESI in prostate cancer (PCa): maximum entropy (MaxEnt) and total variation (TV). Twenty-two patients with PCa with a mean age of 63.8 years (range, 46-79 years) were investigated in this study. A 4D non-uniformly undersampled (NUS) EP-JRESI sequence was implemented on a Siemens 3-T MRI scanner. The NUS data were reconstructed using two non-linear reconstruction methods, namely MaxEnt and TV. Using both TV and MaxEnt reconstruction methods, the following observations were made in cancerous compared with non-cancerous locations: (i) higher mean (choline + creatine)/citrate metabolite ratios; (ii) increased levels of (choline + creatine)/spermine and (choline + creatine)/myo-inositol; and (iii) decreased levels of (choline + creatine)/(glutamine + glutamate). We have shown that it is possible to accelerate the 4D EP-JRESI sequence by four times and that the data can be reliably reconstructed using the TV and MaxEnt methods. The total acquisition duration was less than 13 min and we were able to detect and quantify several metabolites.

  19. Accelerated partial breast irradiation using 3D conformal radiotherapy: initial clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Gatti, M.; Madeddu, A.; Malinverni, G.; Delmastro, E.; Bona, C.; Gabriele, P. [IRCC-Radiotherapy, Candiolo, TO (Italy); Baiotto, B.; Stasi, M. [IRCC-Medical Physics, Candiolo, TO (Italy); Ponzone, R.; Siatis, D. [IRCC-Surgery, Candiolo, TO (Italy)

    2006-11-15

    Accelerated partial breast irradiation using 3D-C.R.T. is technically sophisticate but feasible and acute toxicity to date has been minimal. A C.T.V.-to-P.T.V. margin of 10 mm seems to provide coverage for analyzed patients. However, more patients and additional studies will be needed to validate the accuracy of this margin, and longer follow-up will be needed to assess acute and chronic toxicity, tumor control, and cosmetic results. (author)

  20. Measurements of photon and neutron leakage from medical linear accelerators and Monte Carlo simulation of tenth value layers of concrete used for intensity modulated radiation therapy treatment

    Science.gov (United States)

    Jaradat, Adnan Khalaf

    The x ray leakage from the housing of a therapy x ray source is regulated to be bubble detector of type BD-PND and using Track-Etch detectors. The highest neutron dose equivalent per unit electron dose was at 0° for all electron energies. The neutron leakage from photon beams was the highest between all the machines. Intensity modulated radiation therapy (IMRT) delivery consists of a summation of small beamlets having different weights that make up each field. A linear accelerator room designed exclusively for IMRT use would require different, probably lower, tenth value layers (TVL) for determining the required wall thicknesses for the primary barriers. The first, second, and third TVL of 60Co gamma rays and photons from 4, 6, 10, 15, and 18 MV x ray beams by concrete have been determined and modeled using a Monte Carlo technique (MCNP version 4C2) for cone beams of half-opening angles of 0°, 3°, 6°, 9°, 12°, and 14°.

  1. Effect of the electron transport through thin slabs on the simulation of linear electron accelerators of use in therapy: A comparative study of various Monte Carlo codes

    Energy Technology Data Exchange (ETDEWEB)

    Vilches, M. [Servicio de Fisica y Proteccion Radiologica, Hospital Regional Universitario ' Virgen de las Nieves' , Avda. de las Fuerzas Armadas, 2, E-18014 Granada (Spain)], E-mail: mvilches@ugr.es; Garcia-Pareja, S. [Servicio de Radiofisica Hospitalaria, Hospital Regional Universitario ' Carlos Haya' , Avda. Carlos Haya, s/n, E-29010 Malaga (Spain); Guerrero, R. [Servicio de Radiofisica, Hospital Universitario ' San Cecilio' , Avda. Dr. Oloriz, 16, E-18012 Granada (Spain); Anguiano, M.; Lallena, A.M. [Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain)

    2007-09-21

    When a therapeutic electron linear accelerator is simulated using a Monte Carlo (MC) code, the tuning of the initial spectra and the renormalization of dose (e.g., to maximum axial dose) constitute a common practice. As a result, very similar depth dose curves are obtained for different MC codes. However, if renormalization is turned off, the results obtained with the various codes disagree noticeably. The aim of this work is to investigate in detail the reasons of this disagreement. We have found that the observed differences are due to non-negligible differences in the angular scattering of the electron beam in very thin slabs of dense material (primary foil) and thick slabs of very low density material (air). To gain insight, the effects of the angular scattering models considered in various MC codes on the dose distribution in a water phantom are discussed using very simple geometrical configurations for the LINAC. The MC codes PENELOPE 2003, PENELOPE 2005, GEANT4, GEANT3, EGSnrc and MCNPX have been used.

  2. Effect of Die Head Temperature at Compounding Stage on the Degradation of Linear Low Density Polyethylene/Plastic Film Waste Blends after Accelerated Weathering

    Directory of Open Access Journals (Sweden)

    S. M. Al-Salem

    2016-01-01

    Full Text Available Accelerated weathering test was performed on blends of linear low density polyethylene (LLDPE and plastic film waste constituting the following percentages of polyolefin polymers (wt.%: LLDPE (46%, low density polyethylene (LDPE, 51%, high density polyethylene (HDPE, 1%, and polypropylene (PP, 2%. Compounded blends were evaluated for their mechanical and physical (optical properties. The impact of photodegradation on the formulated blends was studied, and loss of mechanical integrity was apparent with respect to both the exposure duration to weathering and waste content. The effect of processing conditions, namely, the die head temperature (DHT of the blown-film assembly used, was investigated in this work. It was witnessed that surpassing the melting point of the blends constituting polymers did not always result in a synergistic behaviour between polymers. This was suspected to be due to the loss of amorphous region that polyolefin polymers get subjected to with UV exposure under weathering conditions and the effect of the plastic waste constituents. The total change in colour (ΔE did not change with respect to DHT or waste content due to rapid change degradation on the material’s surface. Haze (% and light transmission (% decreased with the increase in waste content which was attributed to lack of miscibility between constituting polymers.

  3. MRI-based brain atrophy rates in ADNI phase 2: acceleration and enrichment considerations for clinical trials.

    Science.gov (United States)

    Hua, Xue; Ching, Christopher R K; Mezher, Adam; Gutman, Boris A; Hibar, Derrek P; Bhatt, Priya; Leow, Alex D; Jack, Clifford R; Bernstein, Matt A; Weiner, Michael W; Thompson, Paul M

    2016-01-01

    The goal of this work was to assess statistical power to detect treatment effects in Alzheimer's disease (AD) clinical trials using magnetic resonance imaging (MRI)-derived brain biomarkers. We used unbiased tensor-based morphometry (TBM) to analyze n = 5,738 scans, from Alzheimer's Disease Neuroimaging Initiative 2 participants scanned with both accelerated and nonaccelerated T1-weighted MRI at 3T. The study cohort included 198 healthy controls, 111 participants with significant memory complaint, 182 with early mild cognitive impairment (EMCI) and 177 late mild cognitive impairment (LMCI), and 155 AD patients, scanned at screening and 3, 6, 12, and 24 months. The statistical power to track brain change in TBM-based imaging biomarkers depends on the interscan interval, disease stage, and methods used to extract numerical summaries. To achieve reasonable sample size estimates for potential clinical trials, the minimal scan interval was 6 months for LMCI and AD and 12 months for EMCI. TBM-based imaging biomarkers were not sensitive to MRI scan acceleration, which gave results comparable with nonaccelerated sequences. ApoE status and baseline amyloid-beta positron emission tomography data improved statistical power. Among healthy, EMCI, and LMCI participants, sample size requirements were significantly lower in the amyloid+/ApoE4+ group than for the amyloid-/ApoE4- group. ApoE4 strongly predicted atrophy rates across brain regions most affected by AD, but the remaining 9 of the top 10 AD risk genes offered no added predictive value in this cohort.

  4. TECHNIQUE OF ESTIMATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 2. Dependence on the characteristics of collimator, optical sourse-distance indicator, treatment field, lasers and treatment couch

    Directory of Open Access Journals (Sweden)

    Y. V. Tsitovich

    2016-01-01

    Full Text Available To ensure the safety of radiation oncology patients needed to provide consistent functional characteristics of the medical linear accelerators, which affect the accuracy of dose delivery. To this end, their quality control procedures, which include the calibration of radiation output of the linac, the error in determining the dose reference value during which must not exceed 2 %, is provided. The aim is to develop a methodology for determining the error (difference between a measured value of quantity and its true value in determining this value, depending on the characteristics of the collimator, the source to surface distance pointer, lasers, radiation field and treatment table. To achieve the objectives have been carried out dosimetric measurements of Trilogy S/N 3567 linac dose distributions, on the basis of which dose errors depending on the accuracy setting the zero position of the collimator, the deviation of the collimator rotation isocenter, the sourcesurface distance pointer accuracy, field size accuracy, the accuracy of lasers and treatment table positioning were obtained. It was found that the greatest impact on the value of the error has the error in the optical SSD indication and the error in the lasers position in the plane perpendicular to the plane of incidence of the radiation beam (up to 3.64 % for the energy of 6 MV. Dose errors caused by error in the field size were different for two photon energies, and reached 2.54 % for 6 MeV and 1.33% for 18 MeV. Errors caused by the rest of the characteristic do not exceed 1 %. Thus, it is possible to express the results of periodic quality control of these devices integrated in linac in terms of dose and use them to conduct a comprehensive assessment of the possibility of clinical use of a linear accelerator for oncology patients irradiation on the basis of the calibration of radiation output in case of development of techniques that allow to analyze the influence dosimetric

  5. Accelerating translational research by clinically driven development of an informatics platform--a case study.

    Science.gov (United States)

    Abugessaisa, Imad; Saevarsdottir, Saedis; Tsipras, Giorgos; Lindblad, Staffan; Sandin, Charlotta; Nikamo, Pernilla; Ståhle, Mona; Malmström, Vivianne; Klareskog, Lars; Tegnér, Jesper

    2014-01-01

    Translational medicine is becoming increasingly dependent upon data generated from health care, clinical research, and molecular investigations. This increasing rate of production and diversity in data has brought about several challenges, including the need to integrate fragmented databases, enable secondary use of patient clinical data from health care in clinical research, and to create information systems that clinicians and biomedical researchers can readily use. Our case study effectively integrates requirements from the clinical and biomedical researcher perspectives in a translational medicine setting. Our three principal achievements are (a) a design of a user-friendly web-based system for management and integration of clinical and molecular databases, while adhering to proper de-identification and security measures; (b) providing a real-world test of the system functionalities using clinical cohorts; and (c) system integration with a clinical decision support system to demonstrate system interoperability. We engaged two active clinical cohorts, 747 psoriasis patients and 2001 rheumatoid arthritis patients, to demonstrate efficient query possibilities across the data sources, enable cohort stratification, extract variation in antibody patterns, study biomarker predictors of treatment response in RA patients, and to explore metabolic profiles of psoriasis patients. Finally, we demonstrated system interoperability by enabling integration with an established clinical decision support system in health care. To assure the usefulness and usability of the system, we followed two approaches. First, we created a graphical user interface supporting all user interactions. Secondly we carried out a system performance evaluation study where we measured the average response time in seconds for active users, http errors, and kilobits per second received and sent. The maximum response time was found to be 0.12 seconds; no server or client errors of any kind were detected

  6. Accelerating translational research by clinically driven development of an informatics platform--a case study.

    Directory of Open Access Journals (Sweden)

    Imad Abugessaisa

    Full Text Available Translational medicine is becoming increasingly dependent upon data generated from health care, clinical research, and molecular investigations. This increasing rate of production and diversity in data has brought about several challenges, including the need to integrate fragmented databases, enable secondary use of patient clinical data from health care in clinical research, and to create information systems that clinicians and biomedical researchers can readily use. Our case study effectively integrates requirements from the clinical and biomedical researcher perspectives in a translational medicine setting. Our three principal achievements are (a a design of a user-friendly web-based system for management and integration of clinical and molecular databases, while adhering to proper de-identification and security measures; (b providing a real-world test of the system functionalities using clinical cohorts; and (c system integration with a clinical decision support system to demonstrate system interoperability. We engaged two active clinical cohorts, 747 psoriasis patients and 2001 rheumatoid arthritis patients, to demonstrate efficient query possibilities across the data sources, enable cohort stratification, extract variation in antibody patterns, study biomarker predictors of treatment response in RA patients, and to explore metabolic profiles of psoriasis patients. Finally, we demonstrated system interoperability by enabling integration with an established clinical decision support system in health care. To assure the usefulness and usability of the system, we followed two approaches. First, we created a graphical user interface supporting all user interactions. Secondly we carried out a system performance evaluation study where we measured the average response time in seconds for active users, http errors, and kilobits per second received and sent. The maximum response time was found to be 0.12 seconds; no server or client errors of any

  7. Verificação do fator de calibração e indicador da qualidade do feixe de aceleradores lineares Verification of dose output and beam quality indicator in linear accelerators

    Directory of Open Access Journals (Sweden)

    Maria da Penha Silva

    2001-10-01

    Full Text Available Um programa de garantia da qualidade é um pré-requisito obrigatório para a exatidão necessária em radioterapia. Este trabalho relata parte dos testes de rotina mensal do controle da qualidade dos aceleradores lineares do Instituto Nacional do Câncer, relativos à calibração dos feixes de fótons e elétrons, no período de dois anos. Os resultados foram comparados com as recomendações do protocolo AAPM TG-40. Na análise do fator de calibração para o feixe de fótons foi encontrado um desvio máximo de 12%; para o feixe de elétrons o maior desvio encontrado foi 10%. A flutuação observada no indicador da qualidade do feixe para os feixes de elétrons foi maior que para os feixes de fótons. Os resultados confirmam a importância de um programa de garantia da qualidade em um serviço de radioterapia, permitindo correções rápidas da dose administrada ao paciente.A quality assurance program is a mandatory prerequisite for obtaining the high level of accuracy required for radiotherapy. This paper reports the results of part of the routine quality control tests for linear accelerators at the National Cancer Institute, Brazil, performed monthly over a period of two years. These tests included dose output and beam quality indicator. The results were compared with the guidelines of the AAPM TG-40 protocol. The results for the photon beams have shown dose output variations of up to 12%; for electron beams, the largest deviation found was 10%. The fluctuations observed in the beam quality indicator for the electron beams were greater than for the photon beams. These results strongly emphasize the importance of a quality assurance program in radiotherapy services in order to allow prompt corrections of the dose delivered to the patient.

  8. 医用电子直线加速器基本原理与职业防护%Basic principles and occupational protection of medical linear accelerators

    Institute of Scientific and Technical Information of China (English)

    张秀文; 张永寿; 郑庆海; 汪鹏飞; 李岩; 宋天一

    2012-01-01

    目的:医用电子直线加速器是目前最常用的放射治疗设备,医用电子直线加速器在肿瘤放射治疗中起主导作用,并取得了相当可观的疗效。分析医用电子直线加速器在正常工作条件下、异常情况下的辐射危害,保证对放射工作人员不会产生确定性效应,发生的随机性效应概率能够控制在可接受的水平。方法:通过制定并全面落实、严格的操作规程和规章制度,强化工作人员安全意识以及配备完善、有效的防护设施,以避免或降低事故照射发生的概率。加速器工作场所进风、排风口的位置设计要合理,风机功率须符合要求。加速器及其工作场所应具有良好的屏蔽设计和多重监控、联锁系统,以保障正常运行的安全。结果:医用电子直线加速器感生放射性辐射水平与加速器的能量、剂量和停机后间隔时间等因素有关。放射性工作人员在医用加速器正常工作条件下受照剂量较低。结论:医用电子直线加速器在正常工作条件下,对放射性工作人员不会产生确定性效应,发生的随机性效应概率能够控制在可接受的水平。%Objective:To investigate the risk of medical linear accelerator for technicians during normal operation to set a standard for protection of its radiation.Methods:In the treatment of cancer,it has made considerable efficacy in radiation therapy,playing a leading role.And it is one of the important equipments to treat cancer.Medical linear accelerator in the normal working conditions will not produce deterministic radiation effects to the staff,and the probability of occurrence of stochastic effects can be controlled at an acceptable level.Results:The radiation level of the device was related to its energy,dosage and intervals of stopping it.The technicians received low dose of radiation during the operation.Conclusion:During normal operation,the device can not exert definite effects

  9. Effects of tertiary MLC configuration on secondary neutron spectra from 18 MV x-ray beams for the Varian 21EX linear accelerator.

    Science.gov (United States)

    Howell, Rebecca M; Kry, Stephen F; Burgett, Eric; Followill, David; Hertel, Nolan E

    2009-09-01

    The effect of the jaw configuration and the presence and configuration of the tertiary multileaf collimator (MLC) on the secondary neutron spectra for an 18 MV Varian 21EX linear accelerator (linac) is investigated in detail. The authors report the measured spectra for four collimator (jaw-and-MLC) configurations. These configurations represent the extreme settings of the jaws and MLC and should therefore describe the range of possible fluence and spectra that may be encountered during use of this linac. In addition to measurements, a Monte Carlo model was used to simulate the four collimator configurations and calculate the energy spectra and fluence at the same location as it was measured. The Monte Carlo model was also used to calculate the sources of neutron production in the linac head for each collimator configuration. They found that photoneutron production in the linac treatment head is dominated by the order in which the primary photon beam intercepts the high-Z material. The primary collimator, which has the highest position in the linac head (in a fixed location), is the largest source of secondary neutrons. Thereafter, the collimator configuration plays a role in where the neutrons originate. For instance, if the jaws are closed, they intercept the beam and contribute substantially to the secondary neutron production. Conversely, if the jaws are open, the MLC plays a larger role in neutron production (assuming, of course, that it intercepts the beam). They found that different collimator configurations make up to a factor of 2 difference in the ambient dose equivalent.

  10. X-ray converter design for an electron linear accelerator%电子直线加速器X射线转换靶设计

    Institute of Scientific and Technical Information of China (English)

    张耀锋; 黄建微; 胡涛; 张明昕; 江艳

    2013-01-01

    设计了用于BF-5电子直线加速器的X射线转换靶.采用蒙特卡罗模拟程序优化计算了靶材厚度;设计了转换靶的冷却结构,并采用有限元方法模拟计算了水冷效果;依据设计的结构参数,计算了转换靶产生X射线的剂量分布及能谱分布.结果表明:靶体温度控制在40℃以下,转换靶在该条件下能够长期稳定工作;X射线平均能量为0.65 MeV,在转换靶正前方1 m处吸收剂量可达6 Gy/min.%The design of an X-ray converter for the BF-5 electron linear accelerator is described.First,the thickness of the converter is optimized by Monte Carlo simulations and the water-cooling structure of the converter is designed.Then,the water cooling process is simulated by finite element analysis and the temperature distribution of the converter is computed.Finally,the dose distribution of the converter as well as the energy spectrum of the generated X-ray is calculated.The results show that the maximal temperature of the converter is below 40 ℃,thus the converter could operate consistently and stably.The mean energy of the generated X-ray is 0.65 MeV,and the absorbed dose of the X-ray for the point 1 meter ahead from the center of the converter could reach 6 Gy/min.

  11. Preclinical imaging and translational animal models of cancer for accelerated clinical implementation of nanotechnologies and macromolecular agents.

    Science.gov (United States)

    De Souza, Raquel; Spence, Tara; Huang, Huang; Allen, Christine

    2015-12-10

    The majority of animal models of cancer have performed poorly in terms of predicting clinical performance of new therapeutics, which are most often first evaluated in patients with advanced, metastatic disease. The development and use of metastatic models of cancer may enhance clinical translatability of preclinical studies focused on the development of nanotechnology-based drug delivery systems and macromolecular therapeutics, potentially accelerating their clinical implementation. It is recognized that the development and use of such models are not without challenge. Preclinical imaging tools offer a solution by allowing temporal and spatial characterization of metastatic lesions. This paper provides a review of imaging methods applicable for evaluation of novel therapeutics in clinically relevant models of advanced cancer. An overview of currently utilized models of oncology in small animals is followed by image-based development and characterization of visceral metastatic cancer models. Examples of imaging tools employed for metastatic lesion detection, evaluation of anti-tumor and anti-metastatic potential and biodistribution of novel therapies, as well as the co-development and/or use of imageable surrogates of response, are also discussed. While the focus is on development of macromolecular and nanotechnology-based therapeutics, examples with small molecules are included in some cases to illustrate concepts and approaches that can be applied in the assessment of nanotechnologies or macromolecules.

  12. Monte Carlo modeling of HD120 multileaf collimator on Varian TrueBeam linear accelerator for verification of 6X and 6X FFF VMAT SABR treatment plans.

    Science.gov (United States)

    Bergman, Alanah M; Gete, Ermias; Duzenli, Cheryl; Teke, Tony

    2014-05-08

    A Monte Carlo (MC) validation of the vendor-supplied Varian TrueBeam 6 MV flattened (6X) phase-space file and the first implementation of the Siebers-Keall MC MLC model as applied to the HD120 MLC (for 6X flat and 6X flattening filter-free (6X FFF) beams) are described. The MC model is validated in the context of VMAT patient-specific quality assurance. The Monte Carlo commissioning process involves: 1) validating the calculated open-field percentage depth doses (PDDs), profiles, and output factors (OF), 2) adapting the Siebers-Keall MLC model to match the new HD120-MLC geometry and material composition, 3) determining the absolute dose conversion factor for the MC calculation, and 4) validating this entire linac/MLC in the context of dose calculation verification for clinical VMAT plans. MC PDDs for the 6X beams agree with the measured data to within 2.0% for field sizes ranging from 2 × 2 to 40 × 40 cm2. Measured and MC profiles show agreement in the 50% field width and the 80%-20% penumbra region to within 1.3 mm for all square field sizes. MC OFs for the 2 to 40 cm2 square fields agree with measurement to within 1.6%. Verification of VMAT SABR lung, liver, and vertebra plans demonstrate that measured and MC ion chamber doses agree within 0.6% for the 6X beam and within 2.0% for the 6X FFF beam. A 3D gamma factor analysis demonstrates that for the 6X beam, > 99% of voxels meet the pass criteria (3%/3 mm). For the 6X FFF beam, > 94% of voxels meet this criteria. The TrueBeam accelerator delivering 6X and 6X FFF beams with the HD120 MLC can be modeled in Monte Carlo to provide an independent 3D dose calculation for clinical VMAT plans. This quality assurance tool has been used clinically to verify over 140 6X and 16 6X FFF TrueBeam treatment plans.

  13. Clinical Sequencing Exploratory Research Consortium: Accelerating Evidence-Based Practice of Genomic Medicine.

    Science.gov (United States)

    Green, Robert C; Goddard, Katrina A B; Jarvik, Gail P; Amendola, Laura M; Appelbaum, Paul S; Berg, Jonathan S; Bernhardt, Barbara A; Biesecker, Leslie G; Biswas, Sawona; Blout, Carrie L; Bowling, Kevin M; Brothers, Kyle B; Burke, Wylie; Caga-Anan, Charlisse F; Chinnaiyan, Arul M; Chung, Wendy K; Clayton, Ellen W; Cooper, Gregory M; East, Kelly; Evans, James P; Fullerton, Stephanie M; Garraway, Levi A; Garrett, Jeremy R; Gray, Stacy W; Henderson, Gail E; Hindorff, Lucia A; Holm, Ingrid A; Lewis, Michelle Huckaby; Hutter, Carolyn M; Janne, Pasi A; Joffe, Steven; Kaufman, David; Knoppers, Bartha M; Koenig, Barbara A; Krantz, Ian D; Manolio, Teri A; McCullough, Laurence; McEwen, Jean; McGuire, Amy; Muzny, Donna; Myers, Richard M; Nickerson, Deborah A; Ou, Jeffrey; Parsons, Donald W; Petersen, Gloria M; Plon, Sharon E; Rehm, Heidi L; Roberts, J Scott; Robinson, Dan; Salama, Joseph S; Scollon, Sarah; Sharp, Richard R; Shirts, Brian; Spinner, Nancy B; Tabor, Holly K; Tarczy-Hornoch, Peter; Veenstra, David L; Wagle, Nikhil; Weck, Karen; Wilfond, Benjamin S; Wilhelmsen, Kirk; Wolf, Susan M; Wynn, Julia; Yu, Joon-Ho

    2016-06-02

    Despite rapid technical progress and demonstrable effectiveness for some types of diagnosis and therapy, much remains to be learned about clinical genome and exome sequencing (CGES) and its role within the practice of medicine. The Clinical Sequencing Exploratory Research (CSER) consortium includes 18 extramural research projects, one National Human Genome Research Institute (NHGRI) intramural project, and a coordinating center funded by the NHGRI and National Cancer Institute. The consortium is exploring analytic and clinical validity and utility, as well as the ethical, legal, and social implications of sequencing via multidisciplinary approaches; it has thus far recruited 5,577 participants across a spectrum of symptomatic and healthy children and adults by utilizing both germline and cancer sequencing. The CSER consortium is analyzing data and creating publically available procedures and tools related to participant preferences and consent, variant classification, disclosure and management of primary and secondary findings, health outcomes, and integration with electronic health records. Future research directions will refine measures of clinical utility of CGES in both germline and somatic testing, evaluate the use of CGES for screening in healthy individuals, explore the penetrance of pathogenic variants through extensive phenotyping, reduce discordances in public databases of genes and variants, examine social and ethnic disparities in the provision of genomics services, explore regulatory issues, and estimate the value and downstream costs of sequencing. The CSER consortium has established a shared community of research sites by using diverse approaches to pursue the evidence-based development of best practices in genomic medicine.

  14. Accelerated clinical discovery using self-reported patient data collected online and a patient-matching algorithm.

    Science.gov (United States)

    Wicks, Paul; Vaughan, Timothy E; Massagli, Michael P; Heywood, James

    2011-05-01

    Patients with serious diseases may experiment with drugs that have not received regulatory approval. Online patient communities structured around quantitative outcome data have the potential to provide an observational environment to monitor such drug usage and its consequences. Here we describe an analysis of data reported on the website PatientsLikeMe by patients with amyotrophic lateral sclerosis (ALS) who experimented with lithium carbonate treatment. To reduce potential bias owing to lack of randomization, we developed an algorithm to match 149 treated patients to multiple controls (447 total) based on the progression of their disease course. At 12 months after treatment, we found no effect of lithium on disease progression. Although observational studies using unblinded data are not a substitute for double-blind randomized control trials, this study reached the same conclusion as subsequent randomized trials, suggesting that data reported by patients over the internet may be useful for accelerating clinical discovery and evaluating the effectiveness of drugs already in use.

  15. Zombie tapeworms in late capitalism: accelerating clinical and reproductive labour in Mira Grant's Parasitology Trilogy.

    Science.gov (United States)

    Attebery, Stina

    2016-12-01

    Biomedicine is increasingly shaped by the speculative economical values of neoliberal capitalism. A key feature of this new bioeconomical regime is the patenting and circulation of organisms and tissue samples, allowing rapid commercialisation of bacterial, animal and human biomedical materials. When thinking about this trend towards commercialisation, we must consider the ways by which biomedicine has been shaped by economics to better address these exploitative relationships between medical researchers and subjects. These fraught questions of agency and exploitation can be addressed through the concept of clinical labour, a term Melinda Cooper and Catherine Waldby coined to discuss embodied forms of labour, including surrogacy, clinical trials and tissue economies, that dominate the post-Fordist biomedical economy. As a genre that extrapolates from contemporary technoscientific practices, science fiction is uniquely positioned to explore the ethics of biomedical research in this neoliberal speculative economy. Science fiction can give human-like agency and affect to microbial, animal and alien life, allowing modified organisms to speak and interact with their creators. Creating these dialogues between commercialised organisms and biomedical researchers makes clear the connections between contemporary clinical practice and exploitative labour relations, illuminating the more troubling aspects of the new bioeconomy and imagining alternatives to this system.

  16. Development of an ultrasmall C-band linear accelerator guide for a four-dimensional image-guided radiotherapy system with a gimbaled x-ray head.

    Science.gov (United States)

    Kamino, Yuichiro; Miura, Sadao; Kokubo, Masaki; Yamashita, Ichiro; Hirai, Etsuro; Hiraoka, Masahiro; Ishikawa, Junzo

    2007-05-01

    We are developing a four-dimensional image-guided radiotherapy system with a gimbaled x-ray head. It is capable of pursuing irradiation and delivering irradiation precisely with the help of an agile moving x-ray head on the gimbals. Requirements for the accelerator guide were established, system design was developed, and detailed design was conducted. An accelerator guide was manufactured and basic beam performance and leakage radiation from the accelerator guide were evaluated at a low pulse repetition rate. The accelerator guide including the electron gun is 38 cm long and weighs about 10 kg. The length of the accelerating structure is 24.4 cm. The accelerating structure is a standing wave type and is composed of the axial-coupled injector section and the side-coupled acceleration cavity section. The injector section is composed of one prebuncher cavity, one buncher cavity, one side-coupled half cavity, and two axial coupling cavities. The acceleration cavity section is composed of eight side-coupled nose reentrant cavities and eight coupling cavities. The electron gun is a diode-type gun with a cerium hexaboride (CeB6) direct heating cathode. The accelerator guide can be operated without any magnetic focusing device. Output beam current was 75 mA with a transmission efficiency of 58%, and the average energy was 5.24 MeV. Beam energy was distributed from 4.95 to 5.6 MeV. The beam profile, measured 88 mm from the beam output hole on the axis of the accelerator guide, was 0.7 mm X 0.9 mm full width at half maximum (FWHM) width. The beam loading line was 5.925 (MeV)-Ib (mA) X 0.00808 (MeV/mA), where Ib is output beam current. The maximum radiation leakage of the accelerator guide at 100 cm from the axis of the accelerator guide was calculated as 0.33 cGy/min at the rated x-ray output of 500 cGy/min from the measured value. This leakage requires no radiation shielding for the accelerator guide itself per IEC 60601-2-1.

  17. Neutron activation processes in the medical linear accelerator Elekta Precise; Procesos de activacion neutronica en el acelerador lineal medico Elekta Precise

    Energy Technology Data Exchange (ETDEWEB)

    Juste, B.; Miro, R.; Verdu, G.; Diez, S.; Campayo, J. M.

    2014-07-01

    In radiotherapy beams of high energy photons produced lower doses in the skin and a lower dose dispersed into surrounding healthy tissue. However, when operating above 10 MV, Linacs have some drawbacks such as the generation of photo-neutrons and activation of some components of the accelerator. The launch and capture of neutrons produce radioactive nuclei that can radiate even when the accelerator is not working. These reactions occur mainly in the heavier materials of the head accelerator. This work has studied the activation generated isotopes resulting, concluding that these derived doses are not negligible. (Author)

  18. Evaluation of a dispersion medium for the irradiation of blood products in a electron linear accelerator; Evaluacion de un medio dispersor para la irradiacion de hemoderivados en un acelerador lineal de electrones

    Energy Technology Data Exchange (ETDEWEB)

    Ordiales, J. M.; Falero, B.; Vazquez, M.; Alvarez, F. J.

    2013-07-01

    The use of bags of rice as dispersion medium in irradiation of blood products for medical use is less effective than the immersion from the point of view dosimetric water. However, given the wide range of dose values for a valid result and once subjected to quality control procedure, the method provides the necessary work for the irradiation of blood products in a linear electron accelerator. (Author)

  19. Determination of the neutron spectra in the treatment room of a linear accelerator for radiotherapy; Determinacion de los espectros de neutrones en la sala de tratamiento de un acelerador lineal para radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R. [Universidad Autonoma de Zacatecas, Cuerpo Academico de Radiobiologia, A.P. 336, 98000 Zacatecas (Mexico); Barquero, R. [Hospital Universitario Rio Hortega, Valladolid (Spain); Mendez, R.; Iniguez, M.P. [Depto. de Fisica Teorica, Atomica, Molecular y Nuclear, Universidad de Valladolid, 47011 Valladolid (Spain)

    2003-07-01

    By means of a series of measures and Monte Carlo calculations the dosimetric characteristics of the photoneutrons have been determined that take place in volume to a linear accelerator of radiotherapy of 18 MV, LINAC, mark Siemens Mevatron model. The measures were carried out with thermoluminescent dosemeters TLD 600 and TLD 700 that were naked exposed and confined with cover of Cd and Sn, inside a sphere of paraffin and inside spheres Bonner. (Author)

  20. Weibull分布对数线性加速模型的可靠性估计方法%Reliability Estimation for Weibull Log-linear Accelerated Life Testing Model

    Institute of Scientific and Technical Information of China (English)

    刘婷

    2011-01-01

    Accelerated life tests,in which more than one stress is often involved, have become widely used in today's industries. The log-linear accelerated model was proposed to describe the relation between multiple-stress and product's lifetime, and Weibull log-linear accelerated models were established. Due to highly nonlinear and non-monotonic of the log likelihood function, the genetic algorithm could be adopted to determine the maximum likelihood estimates of accelerated model parameters, and then reliability assessment and lifetime prediction could be realized under various stress. Finally,simulation results illustrate reasonability of the method proposed in the paper.%针对Weibull分布产品的多应力加速试验,提出采用对数线性加速模型描述多个应力和产品寿命之间的定量关系,建立了Weibull分布对数线性加速试验的可靠性分析模型.鉴于似然函数的高度非线性和非单调特性,采用遗传算法得到了加速模型参数的极大似然估计,可以实现不同应力之间可靠性特性参数的相互转换.仿真算例验证了所提方法的有效性.

  1. Acceleration of tendon healing using US guided intratendinous injection of bevacizumab: First pre-clinical study on a murine model

    Energy Technology Data Exchange (ETDEWEB)

    Dallaudière, Benjamin, E-mail: bendallau64@hotmail.fr [Service de Radiologie, Hôpital universitaire Bichat, Paris (France); Inserm U698, Hôpital universitaire Bichat, Paris (France); Université de Médecine Paris Diderot (France); Lempicki, Marta [Service de Radiologie, Hôpital universitaire Bichat, Paris (France); Université de Médecine Paris Diderot (France); Pesquer, Lionel [Centre d’Imagerie Ostéo Articulaire, Clinique du Sport de Bordeaux-Mérignac (France); Louedec, Liliane [Inserm U698, Hôpital universitaire Bichat, Paris (France); Preux, Pierre Marie [Laboratoire de Biostatistiques, Faculté de médecine, Limoges (France); Meyer, Philippe [Centre d’Imagerie Ostéo Articulaire, Clinique du Sport de Bordeaux-Mérignac (France); Hess, Agathe [Service de Radiologie, Hôpital universitaire Bichat, Paris (France); Université de Médecine Paris Diderot (France); Durieux, Marie Hèlène Moreau [Centre d’Imagerie Ostéo Articulaire, Clinique du Sport de Bordeaux-Mérignac (France); Hummel, Vincent; Larbi, Ahmed [Service de Radiologie, Hôpital universitaire Bichat, Paris (France); Deschamps, Lydia [Service d’ Anatomopathologie, Hôpital universitaire Bichat, Paris (France); and others

    2013-12-01

    Purpose: Tendinopathy shows early disorganized collagen fibers with neo-angiogenesis on histology. Peri-tendinous injection of corticosteroid is the commonly accepted strategy despite the abscence of inflammation in tendinosis. The aim of our study was to assess the potential of intratendinous injection of an anti-angiogenic drug (bevacizumab, AA) to treat tendinopathy in a murine model of patellar and Achilles tendinopathy, and to evaluate its local toxicity. Materials and method: Forty rats (160 patellar and Achilles tendons) were used for this study. We induced tendinosis (T+) in 80 tendons by injecting under ultrasonography (US) guidance Collagenase 1{sup ®} (day 0 = D0, patellar = 40 and Achilles = 40). Clinical examination and tendon US were performed at D3, immediately followed by either AA (AAT+, n = 40) or physiological serum (PST+, n = 40, control) US-guided intratendinous injection. Follow-up at D6 and D13 using clinical, US and histology, and comparison between the 2 groups were performed. To study AA toxicity we compared the 80 remaining normal tendons (T−) after injecting AA in 40 (AAT−). Results: All AAT+ showed a better joint mobilization compared to PST+ at D6 (p = 0.004) with thinner US tendon diameters (p < 0.004), and less disorganized collagen fibers and neovessels on histology (p < 0.05). There was no difference at D13 regarding clinical status, US tendon diameter and histology (p > 0.05). Comparison between AAT− and T− showed no AA toxicity on tendon (p = 0.18). Conclusion: Our study suggests that high dose mono-injection of AA in tendinosis, early after the beginning of the disease, accelerates tendon's healing, with no local toxicity.

  2. High Energy Particle Accelerators

    CERN Multimedia

    Audio Productions, Inc, New York

    1960-01-01

    Film about the different particle accelerators in the US. Nuclear research in the US has developed into a broad and well-balanced program.Tour of accelerator installations, accelerator development work now in progress and a number of typical experiments with high energy particles. Brookhaven, Cosmotron. Univ. Calif. Berkeley, Bevatron. Anti-proton experiment. Negative k meson experiment. Bubble chambers. A section on an electron accelerator. Projection of new accelerators. Princeton/Penn. build proton synchrotron. Argonne National Lab. Brookhaven, PS construction. Cambridge Electron Accelerator; Harvard/MIT. SLAC studying a linear accelerator. Other research at Madison, Wisconsin, Fixed Field Alternate Gradient Focusing. (FFAG) Oakridge, Tenn., cyclotron. Two-beam machine. Comments : Interesting overview of high energy particle accelerators installations in the US in these early years. .

  3. The theory of bipolar disorder as an illness of accelerated aging: implications for clinical care and research.

    Science.gov (United States)

    Rizzo, Lucas Bortolotto; Costa, Leonardo Gazzi; Mansur, Rodrigo B; Swardfager, Walter; Belangero, Síntia Iole; Grassi-Oliveira, Rodrigo; McIntyre, Roger S; Bauer, Moisés E; Brietzke, Elisa

    2014-05-01

    Bipolar Disorder (BD) has been conceptualized as both a cyclic and a progressive disorder. Mechanisms involved in neuroprogression in BD remain largely unknown although several non-mutually exclusive models have been proposed as explanatory frameworks. In the present paper, we propose that the pathophysiological changes observed in BD (e.g. brain structural alterations, cognitive deficits, oxidative stress imbalance, amyloid metabolism, immunological deregulation, immunosenescence, neurotrophic deficiencies and telomere shortening) converge on a model of accelerated aging (AA). Aging can be understood as a multidimensional process involving physical, neuropsychological, and social changes, which can be highly variable between individuals. Determinants of successful aging (e.g environmental and genetic factors), may also confer differential vulnerability to components of BD pathophysiology and contribute to the clinical presentation of BD. Herein we discuss how the understanding of aging and senescence can contribute to the search for new and promising molecular targets to explain and ameliorate neuroprogression in BD. We also present the strengths and limitations of this concept.

  4. [Clinical-pharmacological aspects to accelerate the development process from the preclinical to the clinical phase/1st communication: The contribution of clinical pharmacology].

    Science.gov (United States)

    Kuhlmann, Jochen

    2004-01-01

    To improve the transition from research to development a critical evaluation of the individual project by research and disease area teams is required to include input from pharmacology, toxicology, pharmacokinetics, galenics, clinical pharmacology, clinical as well as regulatory experts and marketing. Decisions on the individual development strategy should be made prior to the start of development and all projects should be reviewed at predefined stages throughout the product development life cycle. This ensures consistency of decision-making not only during the development of individual products but throughout the entire development pipeline. Studies in the exploratory stage of drug development should be designed for decision making in contrast to later clinical trials in the confirmatory stage that require power for proof-of-safety and proof-of-efficacy. The more thorough and profound studies have been carried out during this exploratory stage of drug development, the earlier a decision can be made on the continuation or discontinuation of further development, thus saving development time and money and assessing and considerably reducing the risk for the patients and increasing the success rate of the project in the later confirmatory effectiveness trial with an adequate number of subjects receiving the new therapy under typical conditions of use. Strategies which may be helpful to improve the quality of decisions in drug discovery and drug development are: discovery experiments should be done to critically evaluate the compound, the "killer" experiments should be done as early as possible, continuous effort on preclinical disease models is necessary to improve predictability of efficacy in patients ("humanized" research): genomic technology should be used to identify novel, disease-related targets and to characterise preclinical test systems, improvement of knowledge and experience concerning the relevance of new technologies for the clinical picture; genotyping

  5. Evaluation of a combined respiratory-gating system comprising the TrueBeam linear accelerator and a new real-time tumor-tracking radiotherapy system: a preliminary study.

    Science.gov (United States)

    Shiinoki, Takehiro; Kawamura, Shinji; Uehara, Takuya; Yuasa, Yuki; Fujimoto, Koya; Koike, Masahiro; Sera, Tatsuhiro; Emoto, Yuki; Hanazawa, Hideki; Shibuya, Keiko

    2016-07-08

    A combined system comprising the TrueBeam linear accelerator and a new real-time, tumor-tracking radiotherapy system, SyncTraX, was installed in our institution. The goals of this study were to assess the capability of SyncTraX in measuring the position of a fiducial marker using color fluoroscopic images, and to evaluate the dosimetric and geometric accuracy of respiratory-gated radiotherapy using this combined system for the simple geometry. For the fundamental evaluation of respiratory-gated radiotherapy using SyncTraX, the following were performed:1) determination of dosimetric and positional characteristics of sinusoidal patterns using a motor-driven base for several gating windows; 2) measurement of time delay using an oscilloscope; 3) positional verification of sinusoidal patterns and the pattern in the case of a lung cancer patient; 4) measurement of the half-value layer (HVL in mm AL), effective kVp, and air kerma, using a solid-state detector for each fluoroscopic condition, to determine the patient dose. The dose profile in a moving phantom with gated radiotherapy having a gating window ≤ 4 mm was in good agreement with that under static conditions for each photon beam. The total time delay between TrueBeam and SyncTraX was < 227 ms for each photon beam. The mean of the positional tracking error was < 0.4 mm for sinusoidal patterns and for the pattern in the case of a lung cancer patient. The air-kerma rates from one fluoroscopy direction were 1.93 ± 0.01, 2.86 ± 0.01, 3.92 ± 0.04, 5.28 ± 0.03, and 6.60 ± 0.05 mGy/min for 70, 80, 90, 100, and 110 kV X-ray beams at 80 mA, respectively. The combined system comprising TrueBeam and SyncTraX could track the motion of the fiducial marker and control radiation delivery with reasonable accuracy; therefore, this system provides significant dosimetric improvement. However, patient exposure dose from fluoroscopy was not clinically negligible.

  6. [Clinical study of prejudicing autochthonous speech act (thought)--acceleration of the activity in the remission process of schizophrenia].

    Science.gov (United States)

    Kato, S

    1997-01-01

    Schizophrenics occasionally experience guilty feeling at having insulted someone such as having said "You fool" or "Die" to a new acquaintance. They also experience guilty feeling from autochthonous thought, a feeling of having prejudiced his neighbour. This latter autochthonous thought is considered to be closely related with the former prejudicing speech act. The author would provisionally call these phenomenons of prejudice, prejudicing autochthonous speech act (or prejudicing autochthonous thought), particularly in the case in which the object of prejudice is an intimate real other, or a co-presenting other. Based on his own nine cases, the author has first described the clinical characteristics of this symptom, and then developed psychopathological considerations to draw a attention to the therapeutic importance of this symptom. On the symptomatological ground, the prejudicing autochthonous speech act (thought) belongs to psychomotor verbal hallucinations (J. Séglas), more precisely to the soliloquy type of this hallucination. On the clinical ground, this symptom is likely to follow auditory hallucination caused by an acute state or that of recovery period from this state. Furthermore, it is not infrequent that general improvement as well as remission follow the appearance of this symptom. This symptomatological change of the center of gravity, that is, the gradual transition from auditory hallucination to prejudicing autochthonous speech act (thought) is considered to correspond to a change of the patient's position in relation to others. This position, once experienced passively, is now experienced actively. In other words, the patient, coming out of an acute psychotic state and opening to an intersubjective world, is confronted with a high tension relationship with others. The prejudicing autochthonous speech act (thought) appears in this situation, to restore the patient's own subjectivity in coping with the pressure of real others. In this case, this

  7. Neutron activation processes in the medical linear accelerator Elekta Precise; Procesos de activacion neutronica en el acelerador lineal medico Elekta Precise

    Energy Technology Data Exchange (ETDEWEB)

    Juste, B.; Miro, R.; Verdu, G.; Diez, S.; Campayo, J. M.

    2015-07-01

    Monte Carlo estimation of the giant-dipole-resonance (GRN) photoneutrons insider the Elekta Precise Linac head (emitting a 15 MV photon beam) were performed using the MCNP6 code. Each component of Linac head geometry and materials were modelled in detail using the given manufacturer information. Primary photons generate photoneutrons and its transport across the treatment head was simulated, including the (n, γ) reactions which undergo activation products. The MCNP6 was used to develop a method for quantifying the activation of accelerator components. The approach described in this paper is useful in quantifying the origin and the amount of nuclear activation. (Author)

  8. Uniform Acceleration in General Relativity

    CERN Document Server

    Friedman, Yaakov

    2016-01-01

    We extend de la Fuente and Romero's defining equation for uniform acceleration in a general curved spacetime from linear acceleration to the full Lorentz covariant uniform acceleration. In a flat spacetime background, we have explicit solutions. We use generalized Fermi-Walker transport to parallel transport the Frenet basis along the trajectory. In flat spacetime, we obtain velocity and acceleration transformations from a uniformly accelerated system to an inertial system. We obtain the time dilation between accelerated clocks. We apply our acceleration transformations to the motion of a charged particle in a constant electromagnetic field and recover the Lorentz-Abraham-Dirac equation.

  9. Calculation of dose equivalents in organs due to photoneutrons from clinical accelerators; Calculo de dose equivalente em orgaos devido a fotoneutrons provenientes de aceleradores clinicos

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Robson C. de; Silva, Ademir X. da; Crispim, Verginia R. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: rcastro@con.ufrj.br; Facure, Alessandro; Falcao, Rossana C. [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)]. E-mail: afsoares@cnen.gov.br; Lima, Marco A.F. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Biologia Geral. Lab. de Radiobiologia e Radiometria]. E-mail: egbakel@vm.uff.br

    2005-07-01

    Radiotherapy with photon and electron beams still represents the most technique to control and treat tumour diseases. To increase the treatment efficiency of this technique is linked to the increase of beam energy, resulting in fast neutrons in the radiotherapic beams that contribute with an undesired dose to the patient. In this work has been calculated, using the MCNP4B computer code radiation of transport and an mathematical anthropomorphic phantom, the equivalent doses in organs originated from generated photoneutrons from heads of linear accelerators of medical use, that operates in the 15 MV, 18 MV, 20 MV and 25 MV. The calculated values for the equivalent doses in organs established by the 74 publication of ICRP has show variations between 0.11 mSv.n Gy{sup -1} and 7.03 mSv.n Gy{sup -1}, for the accelerator that uses 18 MV therapic beams, showing good agreement with existing values in the literature. (author)

  10. Preliminary Experience in Treatment of Papillary and Macular Retinoblastoma: Evaluation of Local Control and Local Complications After Treatment With Linear Accelerator-Based Stereotactic Radiotherapy With Micromultileaf Collimator as Second-Line or Salvage Treatment After Chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Pica, Alessia, E-mail: Alessia.Pica@chuv.ch [Department of Radiation Oncology, Centre Hospitalier Universitaire Vaudois, Lausanne (Switzerland); Moeckli, Raphael [University Institute for Radiation Physics, Centre Hospitalier Universitaire Vaudois, Lausanne (Switzerland); Balmer, Aubin [Department of Radiation Oncology, Jules Gonin Eye Hospital, Lausanne (Switzerland); Beck-Popovic, Maja [Unit of Pediatric Oncology, University of Lausanne, Lausanne (Switzerland); Chollet-Rivier, Madeleine [Department of Anesthesiology, University of Lausanne, Lausanne (Switzerland); Do, Huu-Phuoc [University Institute for Radiation Physics, Centre Hospitalier Universitaire Vaudois, Lausanne (Switzerland); Weber, Damien C. [Department of Radiation Oncology, Geneva University Hospital, University of Geneva, Geneva (Switzerland); Munier, Francis L. [Department of Radiation Oncology, Jules Gonin Eye Hospital, Lausanne (Switzerland)

    2011-12-01

    Purpose: To determine the local control and complication rates for children with papillary and/or macular retinoblastoma progressing after chemotherapy and undergoing stereotactic radiotherapy (SRT) with a micromultileaf collimator. Methods and Materials: Between 2004 and 2008, 11 children (15 eyes) with macular and/or papillary retinoblastoma were treated with SRT. The mean age was 19 months (range, 2-111). Of the 15 eyes, 7, 6, and 2 were classified as International Classification of Intraocular Retinoblastoma Group B, C, and E, respectively. The delivered dose of SRT was 50.4 Gy in 28 fractions using a dedicated micromultileaf collimator linear accelerator. Results: The median follow-up was 20 months (range, 13-39). Local control was achieved in 13 eyes (87%). The actuarial 1- and 2-year local control rates were both 82%. SRT was well tolerated. Late adverse events were reported in 4 patients. Of the 4 patients, 2 had developed focal microangiopathy 20 months after SRT; 1 had developed a transient recurrence of retinal detachment; and 1 had developed bilateral cataracts. No optic neuropathy was observed. Conclusions: Linear accelerator-based SRT for papillary and/or macular retinoblastoma in children resulted in excellent tumor control rates with acceptable toxicity. Additional research regarding SRT and its intrinsic organ-at-risk sparing capability is justified in the framework of prospective trials.

  11. 高能大恒KB1800直线加速器MOD连锁故障维修%Introduction of Maintenance of high energy DAHENG KB1800 linear accelerator MOD Chain

    Institute of Scientific and Technical Information of China (English)

    何自怀; 戴国胜; 刘丰华

    2013-01-01

    简要叙述高能大恒KB1800型医用电子直线加速器MOD连锁故障,掌握MOD故障分析和排除的方法,并通过分析速调管故障和处理过程总结此类故障的处理思路、方法和经验.速调管是电子直线加速器中相当昂贵和重要的部件,在安装与拆卸速调管时必须避免水进入高压油箱,否则将导致所有高压油报废,工作人员要严格遵守操作规程并按照维护与保养要求进行维修.%This paper briefly describes the MOD cascading failures of the high energy DAHENG KB1800 medical linear accelerator, mastered the MOD failure by analysis and troubleshooting, and summarizes the relevant solutions and experience by analyzing the failures. The klystron electron linear accelerator is one of important parts and quite expensive. Klystron installation and removal should be guaranteed to prevent water entering the high-pressure fuel tank, otherwise it will lead all the high-pressure oil scrapped. The workers must abide the rules and perform maintenance strictly.

  12. 西门子直线加速器剂量联锁的研究与实践%Practices and researches of dose interlock for SIEMENS linear accelerator~

    Institute of Scientific and Technical Information of China (English)

    杨爱建; 李慧; 钱建锋

    2012-01-01

    目的:在放射治疗中加速器出现剂量联锁后导致停机,并中断治疗。而直线加速器剂量联锁又是加速器各类故障中较为多发的联锁故障,研究探讨相应的通用解决路径,有助于快捷分析排查,及时恢复加速器正常运转,从而保证患者及时按既定计划进行放疗。方法:简要分析剂量联锁及引起剂量联锁的因素,以西门子ONCOR直线加速器的实例,对剂量联锁故障排除技巧进行了剖析,并总结得出解决剂量联锁问题的通用路径。结果:按此通用路径结合实际情况可解决多数加速器的剂量联锁故障,保证了临床放射治疗的进行。结论:实践证明利用这些方法处理加速器剂量联锁切实有效,可帮助提高医学工程技术人员对加速器联锁故障的维修速度与技能。%Objective: In radiation therapy, the accelerator will be stopped and interrupted treatment as soon as dose interlock appeared. And the linear accelerator dose interlock is multiple one in all kinds of the accelerator interlock faults. To study and explore general maintenance skills is in favor of quick analysis, and making the accelerator recovered in time, so as to ensure the normal treatment of the patients timely according to established plan. Methods: The author briefly analyzed the dose interlock and its factors, gave advice general maintenance skills and the general solving path of dose interlock, based on the dose interlock examples of SIEMENS ONCOR linear accelerator. Results: Using the general solving path, connecting with the practice, it can deal with most dose interlock troubleshooting and ensure the clinicalradiation therapy. Conclusion: It has been found that the method to deal with these dose interlock is reliable an~ effective. It can help improve the maintenance speed and skill of dose interlock for engineers and technicians.

  13. Use of microdosing and accelerator mass spectrometry to evaluate the pharmacokinetic linearity of a novel tricyclic GyrB/ParE inhibitor in rats.

    Science.gov (United States)

    Malfatti, Michael A; Lao, Victoria; Ramos, Courtney L; Ong, Voon S; Turteltaub, Kenneth W

    2014-11-01

    Determining the pharmacokinetics (PKs) of drug candidates is essential for understanding their biological fate. The ability to obtain human PK information early in the drug development process can help determine if future development is warranted. Microdosing was developed to assess human PKs, at ultra-low doses, early in the drug development process. Microdosing has also been used in animals to confirm PK linearity across subpharmacological and pharmacological dose ranges. The current study assessed the PKs of a novel antimicrobial preclinical drug candidate (GP-4) in rats as a step toward human microdosing studies. Dose proportionality was determined at 3 proposed therapeutic doses (3, 10, and 30 mg/kg of body weight), and PK linearity between a microdose and a pharmacological dose was assessed in Sprague-Dawley rats. Plasma PKs over the 3 pharmacological doses were proportional. Over the 10-fold dose range, the maximum concentration in plasma and area under the curve (AUC) increased 9.5- and 15.8-fold, respectively. PKs from rats dosed with a (14)C-labeled microdose versus a (14)C-labeled pharmacological dose displayed dose linearity. In the animals receiving a microdose and the therapeutically dosed animals, the AUCs from time zero to infinity were 2.6 ng · h/ml and 1,336 ng · h/ml, respectively, and the terminal half-lives were 5.6 h and 1.4 h, respectively. When the AUC values were normalized to a dose of 1.0 mg/kg, the AUC values were 277.5 ng · h/ml for the microdose and 418.2 ng · h/ml for the pharmacological dose. This 1.5-fold difference in AUC following a 300-fold difference in dose is considered linear across the dose range. On the basis of the results, the PKs from the microdosed animals were considered to be predictive of the PKs from the therapeutically dosed animals.

  14. FFAGS for rapid acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Carol J. Johnstone and Shane Koscielniak

    2002-09-30

    When large transverse and longitudinal emittances are to be transported through a circular machine, extremely rapid acceleration holds the advantage that the beam becomes immune to nonlinear resonances because there is insufficient time for amplitudes to build up. Uncooled muon beams exhibit large emittances and require fast acceleration to avoid decay losses and would benefit from this style of acceleration. The approach here employs a fixed-field alternating gradient or FFAG magnet structure and a fixed frequency acceleration system. Acceptance is enhanced by the use only of linear lattice elements, and fixed-frequency rf enables the use of cavities with large shunt resistance and quality factor.

  15. Elekta和Varian医用直线加速器束流特性的比较研究%Comparison of the beam characteristics between Elekta and Varian medical linear ;accelerator

    Institute of Scientific and Technical Information of China (English)

    葛瑞刚; 徐寿平; 解传滨; 徐伟; 巩汉顺; 丛小虎; 戴相昆

    2016-01-01

    Objective: To analyze and evaluate the differences of beam characteristic for two types of Varian and Elekta medical linear accelerator (Linac) in order to provide the reference of quality assurance (QA) and clinical dosimetric application. Methods:The beam characteristics of the open and 60° wedged fields, such as the percent depth curves (PDDs), the off-axis ratio curves and output factors, were compared for 6 MV X-ray between Varian Clinac iX and Elekta Precise Linac. And the parameters of electron beam energy were analyzed. Results:The radiation quality of X-ray in Varian Clinac iX under the same conditions of open and wedge field was slightly lower than those in Elekta Precise Linac. And the penumbra values (20%~80%) were also smaller. The mean energy of electron beam for 4 or 6 MV in Precise machine was higher than those in Clinac iX, but the mean energy for 12 or 15 MV was lower. The output factors of X-ray and electron beam for the two Linac were a little different. Conclusion:Although the nominal energy in Elekta and Varian Linac are same, the beam characteristics of their X-ray and electron have a little difference due to the collimator structure, parameters or beam calibration standard. Therefore, the dosimetric characteristics of beams during the clinic application should be carefully considered.%目的:分析和评估Varian和Elekta两台医用直线加速器束流特性的差异,为临床准确地实施其质量保证(QA)和剂量学应用提供依据。方法:采用三维水箱测量,比较分析Varian Clinac iX和Elekta Precise直线加速器6 MV X射线辐射源的开野/60°楔形野条件下百分深度曲线(PDD)、输出因子以及束流离轴曲线等束流剂量学特性,并对电子束相同能量的PDD曲线及输出因子等数据进行分析处理。结果:Varian Clinac iX较Elekta Precise医用加速器在开野/楔形野条件下X射线辐射质均略低,其射野半影值(20%~80%)也较小

  16. Implementation of Constant Dose Rate and Constant Angular Spacing Intensity-modulated Arc Therapy for Cervical Cancer by Using a Conventional Linear Accelerator

    Directory of Open Access Journals (Sweden)

    Ruo-Hui Zhang

    2016-01-01

    Conclusions: Patients with cervical cancer treated with CDR-CAS-IMAT using Varian Clinical 23EX can get equivalent or superior dose distribution compared to those treated with IMRT. CDR-CAS-IMAT has a less treatment time and MU, which can reduce the uncertainty factor and patient discomfort in treatment.

  17. 基于直线感应加速器的非相干太赫兹源设计%Design of incoherent THz source based on linear induction accelerator

    Institute of Scientific and Technical Information of China (English)

    禹海军; 王少恒; 荆小兵; 蓝朝晖

    2013-01-01

      太赫兹波的产生途径有很多,本文通过理论设计和数值计算模拟了利用强流直线感应加速器神龙一号来产生 THz波。神龙一号直线感应加速器能够产生最大能量~20 MeV、束流强度~2 kA、脉冲宽度~60 ns 的脉冲电子束,脉冲电子束以不同能量通过偏转半径不相同的偏转磁铁后可以辐射出具有连续频率的太赫兹波。模拟计算了不同能量下的电子束通过偏转半径分别为0.2 m、0.5 m和1 m的偏转磁铁后得到的太赫兹波频率与电子束能量、磁铁偏转半径等的关系,太赫兹波的频率范围可达0.1 THz~9 THz,最大瞬时辐射功率~0.5 W。最后根据神龙一号直线感应加速器漂移段布局,设计得到偏转半径为0.5 m的偏转磁铁结构以及模拟结果。%  There are many methods to generate THz wave. The high current linear induction accelerator Dragon-I is used to produce THz wave by applying the theory design and numerical simulation. The Dragon-I linear induction accelerator can produce intense electron beam with current about 2 kA, maximum energy about 20 MeV and pulse width about 60 ns. The intense electron beams which pass through deflection magnet with different radii can synchronously radiate continuous electromagnetic wave in THz frequency. Using the numerical simulation, the electron beams deflected by the magnets with different radii are calculated, and the relation curves among terahertz wave frequency, electron beam energy and radius of deflection are obtained. The frequency range of THz wave can be up to 0.1 THz-9 THz, and the maximum radiated power can achieve 0.5 W. According to the layout of linear induction accelerator, deflection magnet with 0.5 m radius is simulated and designed lastly.

  18. Study on Accelerating Random Linear Network Coding on Graphics Processors Units%GPU加速随机线性网络编码的研究

    Institute of Scientific and Technical Information of China (English)

    潘晓辉

    2012-01-01

    网络编码近年来被广泛用于各种分布式系统以提高吞吐量,并且能在网络发生动态变化时的数据传输提供弹性.但是,网络编码引起的大量的额外计算量和编码时间成为了实际应用的障碍.在这个研究中,我们使用GPU的强大计算能力来加速网络编码.通过将大量可并行的计算安排到GPU上执行,有效地缩短了网络编码所需要的时间,为网络编码的实际应用提供了帮助.%Network coding has recently been widely applied in various distributed systems for throughput improvement and/or resilience to network dynamics. However, the computational overhead introduced by network coding operations is not negligible and has become the obstacle for practical deployment of network coding. In this study, we exploit the computing power of commodity many-core Graphic Processing Units (GPUs) and multi-core CPUs to accelerate the network coding operations. With the implementation of the algorithms, it is able to achieve significant encoding and decoding throughput, providing a solution for the practical use of network coding.

  19. Joint Newton Iteration and Neumann Series Method of Convergence-Accelerating Matrix Inversion Approximation in Linear Precoding for Massive MIMO Systems

    Directory of Open Access Journals (Sweden)

    Lin Shao

    2016-01-01

    Full Text Available Due to large numbers of antennas and users, matrix inversion is complicated in linear precoding techniques for massive MIMO systems. Several approximated matrix inversion methods, including the Neumann series, have been proposed to reduce the complexity. However, the Neumann series does not converge fast enough. In this paper, to speed up convergence, a new joint Newton iteration and Neumann series method is proposed, with the first iteration result of Newton iteration method being employed to reconstruct the Neumann series. Then, a high probability convergence condition is established, which can offer useful guidelines for practical massive MIMO systems. Finally, simulation examples are given to demonstrate that the new joint Newton iteration and Neumann series method has a faster convergence rate compared to the previous Neumann series, with almost no increase in complexity when the iteration number is greater than or equal to 2.

  20. GBLHT: a GPU-Accelerated Linear Hash Table with Batch Insertion%GBLHT:—种GPU加速的批量插入线性哈希表

    Institute of Scientific and Technical Information of China (English)

    黄玉龙; 奚建清; 张平健; 方晓霖; 刘勇

    2012-01-01

    In order to improve the insertion performance of linear Hash table known as an effective index structure, the existing insertion methods are analyzed, and a linear Hash table GBLHT with batch records insertion, which is combined with the CUDA parallel programming model, is designed and implemented. With the help of the atomic function atomic Add, GBLHT takes full advantage of the high parallel throughput of graphic processing unit (GPU) to implement the lock-free batch insertion of massive records. Some experiments are then carried out to compare the insertion performances of the traditional serial insertion method, the CPU-based batch insertion method and GBLHT. The results show that, under various parameter conditions, the insertion performance of GBLHT is 7 ~ 14 times higher than that of the traditional serial method, and is 3 ~ 6 times higher than that of the CPU-based batch insertion method with four threads.%为改善线性哈希表这一有效索引结构的插入性能,在分析现有方法的基础上,结合CUDA并行编程模型,设计并实现了一种基于GPU的批量插入线性哈希表GBLHT;借助原子函数atomicAdd,GBLHT可以充分利用GPU强大的并行吞吐量来实现大规模记录的无锁批量插入;通过实验对比传统串行插入方法、CPU批量插入方法以及GBLHT的插入性能,发现在不同参数设置条件下,GBLHT的插入性能比传统串行方式提升了7~14倍,与4线程的CPU批量插入方法相比则提升了3~6倍.

  1. Microphthalmia and linear skin defects (MLS) and focal dermal hypoplasia of Goltz (FDHG); Clinical cytogenetic, and molecular studies

    Energy Technology Data Exchange (ETDEWEB)

    Schnur, R.E.; Wick, P.A.; Louis, A. [Childrens Hospital of Philadelphia, PA (United States)

    1994-09-01

    MLS and FDHG syndromes have overlapping phenotypes, including linear skin defects or erosions that heal in cribiform patterns of atrophy and pigmentary change and asymmetric ocular defects. It has been postulated that MLS and FDHG phenotypes reflect changes in the same gene(s) as well as variable X-inactivation patterns. In order to explore this, we studied one new MLS and 2 FDHG patients at clinical, cytogenetic, and molecular levels. Phenotype comparison: We observed a greater variety and wider distribution of cutaneous lesions in FDHG. Only the MLS patient had microphthalmia and sclerocornea with other ocular changes. Skeletal lesions were seen in only one FDHG patient who also had additional problems. Cytogenetics: The MLS patient demonstrated a 46,XX,del(X)(p22) karyotype. We excluded a cryptic Y-translocation by FISH using a Y-chromosome paint. Both FDHG patients had 46,XX karyotypes. Molecular studies: For deletion analysis, somatic cell hybrids containing separated X homologues were made from EBV-transformed LBL lines of all 3 patients. Of 20 hybrids obtained from the MLS patient, only one contained the deleted X, but we recognize that a culture artifact may have occurred in LBL cells prior to fusion. There was also a suggestion of partial skewing of X-homologue representation in FDHG hybrids. The breakpoint for the MLS deletion, which arose on the paternally-derived homologue (by RFLPs), was between DXS16 and AMG; DXS70 and DXS85 were also deleted. This is consistent with reported breakpoints in other MLS patients. Neither FDHG patient was deleted at any of these loci. Our study provides a basis for additional testing in FDHG patients via somatic cell hybrids with new markers and candidate genes from the MLS critical region to confirm or negate the proposed mapping of FDHG to Xp22.3.

  2. Similar clinical outcome after unicompartmental knee arthroplasty using a conventional or accelerated care program: a randomized, controlled study of 40 patients

    DEFF Research Database (Denmark)

    Borgwardt, Lotte; Zerahn, Bo; Bliddal, Henning

    2009-01-01

    BACKGROUND AND PURPOSE Over the last 5 years, there has been increasing interest in reducing length of hospitalization (LOS) through accelerated programs. We examined the clinical outcome of patients undergoing a unicompartmental knee replacement (UKR) in an accelerated care program (A group...... within 3 months, contact with a general physician or nurse, and level of satisfaction were registered. Patients in the A group attended an information meeting. An intraarticular infiltration with Marcaine and adrenaline was used peroperatively. Patients in the C group had an epidural pump for 2 or 3 days......) compared to a conventional care program (C group). METHODS: 40 patients randomized into 2 groups were included (A group: 17 patients; C group: 23 patients). Nausea, micturition problems, lower limb dysfunction, pain (VAS), opiate consumption, Knee Society score (KSS), day of discharge, rehospitalization...

  3. Experience in Control Room Design and Installation of Elekta Axesse Linear Accelerator%医科达Axesse直线加速器机房设计与安装经验

    Institute of Scientific and Technical Information of China (English)

    周舜; 田金; 胥雪东; 马永忠; 杨瑞杰; 王俊杰

    2014-01-01

    本文介绍了Axesse医用直线加速器的机房设计与安装经验,包括建筑设计、空调及通风、电、激光灯、急停开关、照明、防护门、六自由度床、超声定位系统、激光定位系统等,供其他单位借鉴参考。%This paper introduces some experience in the design of control room and installation of Axesse linear accelerator, including the construction design, air conditioner, ventilation, electricity, laser lamp, emergency off, lighting, protective door, HexaPODTM, ultrasound location system, and laser location system.

  4. 磁浮直线电机的分段最大加速度跟踪控制%Maximum Acceleration Tracing Control for the Single-sided Linear Induction Motor

    Institute of Scientific and Technical Information of China (English)

    陈特放; 邓江明; 唐建湘; 成庶

    2015-01-01

    单边直线感应电机(Single-sided Linear Induction Motors,SLIMs)作为中低速磁悬浮列车的驱动装置,其推力和法向力的优良控制特性以及抗干扰能力,对于列车的牵引及悬浮系统稳定高效运行极为重要。通过建立SLIM的最大加速度变电流跟踪控制模型,在加/减速区,控制SLIM以恒定最大加速度运行;在稳速区,为充分利用电机的容量,控制SLIM恒功率运行。实验验证了所提控制算法的有效性,不仅能有效研究SLIM推力特性,还能为探索磁悬浮的高效动态控制方法提供参考。%On the premise of constant slip-frequency, an approach of variant current with maximum acceleration is proposed to achieve high efficiency control of Single-sided Linear Induction Motors (SLIMs). By regulating current, the thrust is kept with positive or negative to minimize time consumption in acceleration or deceleration sections, respectively, and zero value to bring SLIM into constant power running status in stability sections. Validity of the proposed algorithm is verified by experimental results, and this approach may have some implement value in maglev transportation control.

  5. Piperacillin-tazobactam-induced linear IgA bullous dermatosis presenting clinically as Stevens-Johnson syndrome/toxic epidermal necrolysis overlap.

    Science.gov (United States)

    Adler, N R; McLean, C A; Aung, A K; Goh, M S Y

    2017-04-01

    Linear IgA bullous dermatosis (LABD) is a subepidermal autoimmune bullous disease characterized by linear IgA deposition at the basement membrane zone, which is visualized by direct immunofluorescence. Patients with LABD typically present with widespread vesicles and bullae; however, this is not necessarily the case, as the clinical presentation of this disease is heterogeneous. LABD clinically presenting as Stevens-Johnson syndrome (SJS) or toxic epidermal necrolysis (TEN) is an infrequent, yet well-described phenomenon. Most cases of LABD are idiopathic, but some cases are drug-induced. Multiple drugs have been implicated in the development of LABD. We report a case of piperacillin-tazobactam-induced LABD presenting clinically as SJS/TEN overlap. This is the first reported case of a strong causal association between piperacillin-tazobactam and the development of LABD.

  6. Definition of a reference metrology network for the positioning of a large linear accelerator; Definition d'un reseau de reference metrologique pour le positionnement d'un grand accelerateur lineaire

    Energy Technology Data Exchange (ETDEWEB)

    Becker, F

    2003-12-15

    This thesis is a study of the Compact Linear Collider (CLIC) alignment system, a project of linear accelerator of about 30 km long of the European Organization for Nuclear Research (CERN). The pre-alignment tolerance on the transverse positions of the components of the CLIC linacs is typically ten microns over distances of 200 m. This research is a consequence of 10 years work, where several sets of special sensors dedicated to metrology have been adapted for the CLIC project. Most of these sensors deliver measurements linked to geometric references sensitive to gravity fluctuation. An important part of this work is therefore dedicated to study the gravity disruptions as a high level of accuracy is required. The parameters to take into account in the use of the hydrostatic leveling have thus been highlighted. A proposal of configuration of the system alignment based on a selection of sensors has also been given in this research. Computer models of different possible configurations have been presented. As the existing computing software was inappropriate, a new object oriented software package has been developed, to ensure future upgrades. An optimized configuration of the network has been defined from a set of simulations. Finally, due to problems in the use of hydrostatic leveling systems, a solution based on the use of a long laser beam as an alternative solution is discussed. (author)

  7. The use of enriched 6Li and 7Li Lif:Mg,Cu,P glass-rod thermoluminescent dosemeters for linear accelerator out-of-field radiation dose measurements.

    Science.gov (United States)

    Takam, R; Bezak, E; Liu, G; Marcu, L

    2012-06-01

    (6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescent dosemeters (TLDs) were used for measurements of out-of-field photon and neutron doses produced by Varian iX linear accelerator. Both TLDs were calibrated using 18-MV X-ray beam to investigate their dose-response sensitivity and linearity. CR-39 etch-track detectors (Luxel+, Landauer) were employed to provide neutron dose data to calibrate (6)LiF:Mg,Cu,P TLDs at various distances from the isocentre. With cadmium filters employed, slow neutrons (neutrons. The average in-air photon dose equivalents per monitor unit (MU) ranged from 1.5±0.4 to 215.5±94.6 μSv at 100 and 15 cm from the isocentre, respectively. Based on the cross-calibration factors obtained with CR-39 etch-track detectors, the average in-air fast neutron dose equivalents per MU range from 10.6±3.8 to 59.1±49.9 μSv at 100 and 15 cm from the isocentre, respectively. Contribution of thermal neutrons to total neutron dose equivalent was small: 3.1±7.2 μSv per MU at 15 cm from the isocentre.

  8. High Gradient Accelerator Research

    Energy Technology Data Exchange (ETDEWEB)

    Temkin, Richard [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States). Dept. of Physics. Plasma Science and Fusion Center

    2016-07-12

    The goal of the MIT program of research on high gradient acceleration is the development of advanced acceleration concepts that lead to a practical and affordable next generation linear collider at the TeV energy level. Other applications, which are more near-term, include accelerators for materials processing; medicine; defense; mining; security; and inspection. The specific goals of the MIT program are: • Pioneering theoretical research on advanced structures for high gradient acceleration, including photonic structures and metamaterial structures; evaluation of the wakefields in these advanced structures • Experimental research to demonstrate the properties of advanced structures both in low-power microwave cold test and high-power, high-gradient test at megawatt power levels • Experimental research on microwave breakdown at high gradient including studies of breakdown phenomena induced by RF electric fields and RF magnetic fields; development of new diagnostics of the breakdown process • Theoretical research on the physics and engineering features of RF vacuum breakdown • Maintaining and improving the Haimson / MIT 17 GHz accelerator, the highest frequency operational accelerator in the world, a unique facility for accelerator research • Providing the Haimson / MIT 17 GHz accelerator facility as a facility for outside users • Active participation in the US DOE program of High Gradient Collaboration, including joint work with SLAC and with Los Alamos National Laboratory; participation of MIT students in research at the national laboratories • Training the next generation of Ph. D. students in the field of accelerator physics.

  9. The Accelerated Kepler Problem

    CERN Document Server

    Namouni, Fathi

    2007-01-01

    The accelerated Kepler problem is obtained by adding a constant acceleration to the classical two-body Kepler problem. This setting models the dynamics of a jet-sustaining accretion disk and its content of forming planets as the disk loses linear momentum through the asymmetric jet-counterjet system it powers. The dynamics of the accelerated Kepler problem is analyzed using physical as well as parabolic coordinates. The latter naturally separate the problem's Hamiltonian into two unidimensional Hamiltonians. In particular, we identify the origin of the secular resonance in the accelerated Kepler problem and determine analytically the radius of stability boundary of initially circular orbits that are of particular interest to the problem of radial migration in binary systems as well as to the truncation of accretion disks through stellar jet acceleration.

  10. Effect of dietary, social, and lifestyle determinants of accelerated aging and its common clinical presentation: A survey study.

    Science.gov (United States)

    Samarakoon, S M S; Chandola, H M; Ravishankar, B

    2011-07-01

    Aging is unavoidable and natural phenomenon of life. Modern gerontologists are realizing the fact that aging is a disease, which Ayurveda had accepted as natural disease since long. Rate of aging is determined by one's biological, social, lifestyle, and psychological conditions and adversity of which leads to accelerated form of aging (Akalaja jara or premature aging). The aim of this study is to identify potential factors that may accelerate aging in the context of dietry factors, lifestyle and mental makeup. The 120 diagnosed subjects of premature-ageing of 30-60 years were randomly selected in the survey study. Premature ageing was common among females (75.83%), in 30-40 age group (70%), 86.67% were married, had secondary level of education (36.66%), house-views (61.67%), belongs top middle class (58.33%) and engaged in occupations that dominating physical labour (88.33%). The maximum patients are constipated (60%), had mandagni (80%), vata-kapha prakriti (48.33%), rajasika prakriti (58.33%), madhyama vyayama shakti (73.33%), and madhyama jarana shakti (85.83%). Collectively, 43.33% patients were above normal BMI. The more patients had anushna (38.33%) and vishamasana dietary pattern (25.83%), consumed Lavana (88.33%) and Amla rasa (78.33%) in excess on regular basis. Some patients had addicted to tobacco (11.67%) and beetle chewing (5.83%). The maximum patients had no any exercise (79.17%) and specific hobby (79.17%) in their leisure times. Analyzing Hamilton Anxiety and Depression Rating Scales revealed that 39.80%, 37.86%, 33.98%, 24.27% and 18.44% patients had insomnia, depression, tension, GIT symptoms and anxious mood respectively. These data suggest that certain social, dietary and lifestyle factors contribute towards accelerated ageing among young individuals.

  11. Identifying Patients Who May Be Candidates for a Clinical Trial of Salvage Accelerated Partial Breast Irradiation after Previous Whole Breast Irradiation

    Directory of Open Access Journals (Sweden)

    Linna Li

    2012-01-01

    Full Text Available Background and Objectives. Accelerated partial breast irradiation (APBI has been proposed as an alternative to salvage mastectomy for patients with ipsilateral breast tumor recurrence (IBTR after prior breast conservation. We studied factors that are associated with a more favorable local recurrence profile that could make certain patients eligible for APBI. Methods. Between 1980 and 2005, 157 Stage 0–II breast cancer patients had an IBTR treated by mastectomy. Clinical and pathological features were analyzed to identify factors associated with favorable IBTR defined as unifocal DCIS or T1 ≤ 2 cm, without skin involvement, and >2 year interval from initial treatment. Results. Median followup was 140 months and time to recurrence was 73 months. Clinical stage distribution at recurrence was DCIS in 32 pts (20%, T1 in 90 pts (57%, T2 in 14 pts (9%, T3 in 4 pts (3%, and T4 in 9 pts (6%. IBTR was classified as favorable in 71%. Clinical stage of IBTR predicted for pathologic stage –95% of patients with clinical T1 IBTR had pathologic T1 disease at salvage mastectomy . Conclusions. Clinical stage at presentation strongly correlated with pathologic stage at mastectomy. More than 70% of recurrences were favorable and may be appropriate candidates for salvage APBI trials.

  12. Symposium report on frontier applications of accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Parsa, Z. [ed.

    1993-09-28

    This report contains viewgraph material on the following topics: Electron-Positron Linear Colliders; Unconventional Colliders; Prospects for UVFEL; Accelerator Based Intense Spallation; Neutron Sources; and B Physics at Hadron Accelerators with RHIC as an Example.

  13. On-ground experimental investigation of a linear acceleration based body mass measurement method%基于直线加速度的人体质量测量方法及其地面实验研究

    Institute of Scientific and Technical Information of China (English)

    严辉; 李路明; 郝红伟; 胡春华

    2012-01-01

    Human body measurements in micro〉gravity environments are important for health monitoring of astronauts in long:term manned space missions. This study analyzes the linear acceleration method which is based on Newton's second law. An onground experimental platform was developed consisting of a spring cam assembly to generate a constant pulling force to linearly accelerate the human body and an air bearing table to simulate the micro-gravity environment in the horizontal directions. Rigid weights from 45 90 kg and 15 human subjects from 50- 60 kg were tested. The results show that the method satisfies Newton's second law with measurement accuracy of 0.2 kg for the rigid weights. Good repeatability is observed for the humans and the accuracy is approximately 0.5 kg. The results indicate that the linear acceleration method is useful for human body mass measurements in micro-gravity environments and that the measurement error can be reduced by longer motion times, better body restriction and proper training of the human subjects.%微重力条件下的人体质量测量方法和设备对于长期载人航天的航天员健康监测具有重要意义。该文比较了可行的测量方法,选取了基于Newton第二定律的直线加速度法进行地面实验研究。搭建了实验平台,利用弹簧-凸轮的恒力机构产生恒定拉力牵引人体做直线匀加速运动,利用气浮台模拟水平方向微重力条件,对45~90kg的刚性砝码和15名50~60kg的人体被试进行测量实验。实验结果显示:该实验平台符合匀加速直线运动规律,标定后对刚性砝码测量精度优于0.2kg,对于人体测量结果稳定性较高,整体精度在0.5kg左右。可见,直线加速度方法可以用于微重力下人体质量测量,通过延长运动时间、加强人体的固定和增加被试者训练等方法应可得到较好精度。

  14. 多线程技术在LIA中两路束流测量的实现%Implementation of Double Electron Beam Measurement of Linear Induction Accelerator with Multithreading Technology

    Institute of Scientific and Technical Information of China (English)

    王远; 张开志; 江孝国; 杨国君; 李劲

    2009-01-01

    强流脉冲电子束作为一种高亮度的光源,具有广阔的应用前景,而双轴束流测量的控制对于研究产生电子束的加速器技术具有重要意义;利用多线程技术在CVI环境下的实现方法,研究了双路束流参数特点、双路束流测量的时序同步控制方法,在此基础上采用线程池多线程技术实现基于TCP/IP的加速器束流测量的数据采集软件,结果表明采用多线程技术可以很好地实现多任务的同时工作,有助于提高束测量的响应速度和测量的执行效率.%The intense current pulsed electron beam is a new kind of light source with very high brightness and is very useful. The control technology of double axial orientation electron beam measurement is very important for the study of linear induction accelerator (LIA)which produce the electron beam. In order to meet the demand of measuring the double electron beam by Muhithreading Technology, a new method for the beam measurement and synchronous control has been developed, the software of beam measurement of accelerator can be implemented with multithreading technology by TCP/IP; The method can ensure synchronous work by multithreading technology and the method can improve response speed and measurement efficiency.

  15. Future accelerators (?)

    Energy Technology Data Exchange (ETDEWEB)

    John Womersley

    2003-08-21

    I describe the future accelerator facilities that are currently foreseen for electroweak scale physics, neutrino physics, and nuclear structure. I will explore the physics justification for these machines, and suggest how the case for future accelerators can be made.

  16. Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife{sup Registered-Sign} and linear accelerators equipped with microMLC and circular cones

    Energy Technology Data Exchange (ETDEWEB)

    Bassinet, C.; Huet, C.; Derreumaux, S.; Baumann, M.; Trompier, F.; Roch, P.; Clairand, I. [Institut de Radioprotection et de Surete Nucleaire (IRSN), BP17, 92262 Fontenay-aux-Roses Cedex (France); Brunet, G.; Gaudaire-Josset, S. [Institut de Cancerologie de l' Ouest Rene Gauducheau, bd Jacques Monod, 44805 Saint Herblain Cedex (France); Chea, M.; Boisserie, G. [Groupe Hospitalier Pitie-Salpetriere, 47/83 bd de l' Hopital, 75651 Paris Cedex 13 (France); Lacornerie, T. [Centre Oscar Lambret, 3, rue Frederic Combemale, BP 307, 59020 Lille Cedex (France)

    2013-07-15

    Purpose: The use of small photon fields is now an established practice in stereotactic radiosurgery and radiotherapy. However, due to a lack of lateral electron equilibrium and high dose gradients, it is difficult to accurately measure the dosimetric quantities required for the commissioning of such systems. Moreover, there is still no metrological dosimetric reference for this kind of beam today. In this context, the first objective of this work was to determine and to compare small fields output factors (OF) measured with different types of active detectors and passive dosimeters for three types of facilities: a CyberKnife{sup Registered-Sign} system, a dedicated medical linear accelerator (Novalis) equipped with m3 microMLC and circular cones, and an adaptive medical linear accelerator (Clinac 2100) equipped with an additional m3 microMLC. The second one was to determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors introduced in a recently proposed small field dosimetry formalism for different active detectors.Methods: Small field sizes were defined either by microMLC down to 6 Multiplication-Sign 6 mm{sup 2} or by circular cones down to 4 mm in diameter. OF measurements were performed with several commercially available active detectors dedicated to measurements in small fields (high resolution diodes: IBA SFD, Sun Nuclear EDGE, PTW 60016, PTW 60017; ionizing chambers: PTW 31014 PinPoint chamber, PTW 31018 microLion liquid chamber, and PTW 60003 natural diamond). Two types of passive dosimeters were used: LiF microcubes and EBT2 radiochromic films.Results: Significant differences between the results obtained by several dosimetric systems were observed, particularly for the smallest field size for which the difference in the measured OF reaches more than 20%. For passive dosimeters, an excellent agreement was observed (better than 2%) between EBT2 and LiF microcubes

  17. 一种直线加速器电离室保护装置的研制%Development and research of an ionization chamber protection device on linear accelerator

    Institute of Scientific and Technical Information of China (English)

    程江波; 陈卫彬; 张帅; 严勇

    2011-01-01

    目的:为了减少因电离室工作温度、湿度变化引起的直线加速器故障,延长直线加速器电离室使用寿命,设计一种电离室保护装置.方法:通过使用温度23℃、湿度15%、流量10L/min的干燥空气吹拂电离室的方法,改变电离室的工作环境,减少外部应用环境的变化对电离室产生的不良影响.结果:将装置安装在2台直线加速器上使用,同比上年同期的故障次数,故障率减少80%以上.结论:通过实际运行及参数检测,该电离室保护装置运行稳定,在一定程度上改善了电离室的工作环境,可以减少外部应用环境的变化对电离室产生的不良影响,减少电离室故障,延长使用寿命.%Objective: To design a protection device on ionization chamber to reduce the failure of linear accelerator that caused by changes in ionization chamber's temperature and humidity, and extend the service life of ionization chamber. Methods: The working environment of ionization chamber was changed by using the temperature 23 ℃ , humidity 15%, flow 10 l/min dry air blowing chamber, reducing the adverse effect of the ionization chamber by external environment changes. Results: This device was installed on two linear accelerator equipments. Number of failures compared the same period last year reduced by 80% at least. Conclusion: By the actual operation, the ionization chamber protection device is stable and can be used to improve the working environment of the ionization chamber and reduce the adverse environmental impacts, reduce failures and extend life.

  18. Comparison of analytical and clinical performance of CLART HPV2 genotyping assay to Linear Array and Hybrid Capture 2

    DEFF Research Database (Denmark)

    Ejegod, Ditte Møller; Rebolj, Matejka; Bonde, Jesper

    2015-01-01

    prone to inter-observer variability. The reading of test results on the CLART HPV2 genotyping assay is, on the other hand, automated. The aim of our study was to directly compare the detection of HPV genotypes and high-grade cervical intraepithelial neoplasia (CIN) by CLART, Linear Array (LA...

  19. Muon Acceleration - RLA and FFAG

    Energy Technology Data Exchange (ETDEWEB)

    Bogacz, Alex

    2011-10-01

    Various acceleration schemes for muons are presented. The overall goal of the acceleration systems: large acceptance acceleration to 25 GeV and 'beam shaping' can be accomplished by various fixed field accelerators at different stages. They involve three superconducting linacs: a single pass linear Pre-accelerator followed by a pair of multi-pass Recirculating Linear Accelerators (RLA) and finally a non-scaling FFAG ring. The present baseline acceleration scenario has been optimized to take maximum advantage of appropriate acceleration scheme at a given stage. The solenoid based Pre-accelerator offers very large acceptance and facilitates correction of energy gain across the bunch and significant longitudinal compression trough induced synchrotron motion. However, far off-crest acceleration reduces the effective acceleration gradient and adds complexity through the requirement of individual RF phase control for each cavity. The RLAs offer very efficient usage of high gradient superconducting RF and ability to adjust path-length after each linac pass through individual return arcs with uniformly periodic FODO optics suitable for chromatic compensation of emittance dilution with sextupoles. However, they require spreaders/recombiners switchyards at both linac ends and significant total length of the arcs. The non-scaling Fixed Field Alternating Gradient (FFAG) ring combines compactness with very large chromatic acceptance (twice the injection energy) and it allows for large number of passes through the RF (at least eight, possibly as high as 15).

  20. High-brightness rf linear accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Jameson, R.A.

    1986-01-01

    The issue of high brightness and its ramifications in linacs driven by radio-frequency fields is discussed. A history of the RF linacs is reviewed briefly. Some current applications are then examined that are driving progress in RF linacs. The physics affecting the brightness of RF linacs is then discussed, followed by the economic feasibility of higher brightness machines. (LEW)

  1. Operation and maintenance linear accelerator. Conference summary

    Energy Technology Data Exchange (ETDEWEB)

    Feldman, G.J.

    1983-01-01

    In the opening talk of this meeting, G. Kane defined the minimal standard model to be: (a) three generations of quarks and leptons; (b) massless neutrinos; (c) SU(3)/sub colour/ x SU(2)/sub L/ gauge theory; (d) one neutral Higgs boson; and (e) CP violation solely in the mass matrix. Reaching this point has been the tremendous achievement of the past decade. We have witnessed the discoveries of charm and the third generation, the discovery of neutral currents and the detailed confirmation of SU(2)/sub L/ x U(1), and the discovery of asymptotic freedom and the development of QCD and its experimental tests. In spite of these achievements, the resulting standard model is not entirely esthetically pleasing. It lacks a coherence which would explain its varied form and parameters; as a result, I would wager that none of us here believes that it represents the end of physics. A review of experimental activities is given. These fall into three general categories: searching for evidence of physics beyond the minimal standard model, testing the standard model, and making detailed measurements within this standard model. (WHK)

  2. Accelerators for heavy-charged-particle radiation therapy.

    Science.gov (United States)

    Coutrakon, George B

    2007-08-01

    This paper focuses on current and future designs of medical hadron accelerators for treating cancers and other diseases. Presently, five vendors and several national laboratories have produced heavy-particle medical accelerators for accelerating nuclei from hydrogen (protons) up through carbon and oxygen. Particle energies are varied to control the beam penetration depth in the patient. As of the end of 2006, four hospitals and one clinic in the United States offer proton treatments; there are five more such facilities in Japan. In most cases, these facilities use accelerators designed explicitly for cancer treatments. The accelerator types are a combination of synchrotrons, cyclotrons, and linear accelerators; some carry advanced features such as respiration gating, intensity modulation, and rapid energy changes, which contribute to better dose conformity on the tumor when using heavy charged particles. Recent interest in carbon nuclei for cancer treatment has led some vendors to offer carbon-ion and proton capability in their accelerator systems, so that either ion can be used. These features are now being incorporated for medical accelerators in new facilities.

  3. Seven Cases of Troubleshooting and Analysis on VARIAN IX Medical Linear Accelerator%VARIAN IX直线加速器7例故障维修与分析

    Institute of Scientific and Technical Information of China (English)

    桂龙刚; 石苗; 李军; 张西志; 汪步海; 侯笑笑

    2016-01-01

    This paper briefly introduced seven cases of malfunctions occurred in the VARIAN IX linear accelerator during operation, i.e., control board malfunction of electronic gun (GFIL interlock), modulator malfunction (HVCB interlock), energy programming board malfunction (EXQ1), energy conversion potentiometer malfunction (CARR interlock), MLC malfunction, thermostat valve malfunction (PUMP interlock) and ionization chamber malfunction (ION interlock). Moreover, malfunction cases analyzed and troubleshooting methods presented in this paper can provide reference for coleagues.%该文简要介绍VARIAN IX直线加速器在使用过程中碰到的7例典型故障,它们分别是电子枪控制板故障(GFIL联锁)、调制器故障(HVCB联锁)、能量编程板故障(EXQ1)、能量转换电位器故障(CARR联锁)、MLC故障、温控阀故障(PUMP联锁)和电离室故障(ION联锁)。通过对故障实例的分析并介绍故障排除的方法,为同行提供参考。

  4. Response of CaSO{sub 4}:Dy phosphor based TLD badge system to high energy electron beams from medical linear accelerator and estimation of whole body dose and skin dose

    Energy Technology Data Exchange (ETDEWEB)

    Chatterjee, S. [TLD Unit, RPAD, VECC/BARC, Kolkata 700 064 (India); Bakshi, A.K. [RPAD, BARC, Trombay, Mumbai 400 085 (India)], E-mail: akbakshi123@yahoo.com; Kinhikar, R.A. [Department of Medical Physics, Tata Memorial Hospital, Earnest Borges Marg, Parel, Mumbai 400 012 (India); Chourasiya, G.; Kher, R.K. [RPAD, BARC, Trombay, Mumbai 400 085 (India)

    2009-03-15

    Response of thermoluminescent dosimeter (TLD) badge based on CaSO{sub 4}:Dy phosphor to high energy electron beams from medical linear accelerators was simulated using FLUKA Monte Carlo code and experimentally verified. This study was carried out in order to determine the response of TL discs under different filter regions of the TLD badge and their ratios under different irradiation conditions in the energy range 6-20 MeV of high energy electron beams. It was found that the response of TL disc under metal filters of the TLD badge (D1) is always higher than the response of the TL discs under Polystyrene filter (D2) and open window (D3) and its response was found to decrease with increase in the energy of the electron beam. Estimation of whole body dose and skin dose including its error was carried out as an extension of the present study in case of accidental exposure of radiation worker to high energy electron beam.

  5. Damage diagnosis for bremsstrahlung converter target of Dragon-I linear induction accelerator%神龙一号直线感应加速器X光转换靶破坏诊断

    Institute of Scientific and Technical Information of China (English)

    禹海军; 朱隽; 江孝国; 王远; 陈楠; 张振涛; 戴文华; 刘承俊

    2011-01-01

    The electron beam generated by the Dragon- I linear induction accelerator strikes the bremsstrahlung converter target to generate X-ray and causes tantalum target damage and hydrodynamic expansion, which results in target density decreasing for successive pulses.The time varying target density was measured by applying a low energy X-ray with energy about 450 kev and spot diameter of 1 to 4 mm along with an intensified charge coupled derice(ICCD) camera.The experiment results show that the target density is basically unchanged for 1 μs after beam-target interaction, and no particle ejected from the front side of the target is found at the same time.%利用能量约450 keV、焦斑直径1~4 mm的低能X光对神龙一号直线感应加速器束靶作用后钽靶的破坏进行诊断,利用增强型电荷耦合器件(ICCD)对诊断过程记录,得到束靶作用后数μs时间内钽靶材料密度的变化.结果表明:在束靶作用后约1μs内靶材料密度基本没有变化,且该时间段内ICCD相机没有观察到有靶前钽靶材料的微粒喷射.

  6. NIIEFA accelerators for applied purposes

    Science.gov (United States)

    Vorogushin, M. F.; Strokach, A. P.; Filatov, O. G.

    2016-12-01

    Since the foundation of the institute, we have designed and delivered more than three hundred different accelerators to Russia and abroad: cyclotrons, linear accelerators, and neutron generators. The technical characteristics of our equipment makes it competitive on the international market. Here we present the application, main parameters, and status of accelerators manufactured by NIIEFA, as well as prospects for the development of electrophysical systems for applied purposes.

  7. Collective accelerator for electron colliders

    Energy Technology Data Exchange (ETDEWEB)

    Briggs, R.J.

    1985-05-13

    A recent concept for collective acceleration and focusing of a high energy electron bunch is discussed, in the context of its possible applicability to large linear colliders in the TeV range. The scheme can be considered to be a member of the general class of two-beam accelerators, where a high current, low voltage beam produces the acceleration fields for a trailing high energy bunch.

  8. Vibration control in accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Montag, C.

    2011-01-01

    In the vast majority of accelerator applications, ground vibration amplitudes are well below tolerable magnet jitter amplitudes. In these cases, it is necessary and sufficient to design a rigid magnet support structure that does not amplify ground vibration. Since accelerator beam lines are typically installed at an elevation of 1-2m above ground level, special care has to be taken in order to avoid designing a support structure that acts like an inverted pendulum with a low resonance frequency, resulting in untolerable lateral vibration amplitudes of the accelerator components when excited by either ambient ground motion or vibration sources within the accelerator itself, such as cooling water pumps or helium flow in superconducting magnets. In cases where ground motion amplitudes already exceed the required jiter tolerances, for instance in future linear colliders, passive vibration damping or active stabilization may be considered.

  9. Sensitivity analysis the influence of the average energy and FWHM of the initial fluence electrons in the determination of a spectrum of photons Bremsstrahlung of a linear accelerator; Analisis de sensibilidad de la influencia de la energia media y FWHM de la fluencia inicial de electrones en la determinacion de un espectro de fotones Bremsstrahlung de accelerador lineal

    Energy Technology Data Exchange (ETDEWEB)

    Justo, B.; Miro, R.; Verdu, G.; Diez, S.; Campayo, J. M.

    2011-07-01

    The main objective of this work is to study the effects of the initial beam characteristics of electrons in the absorbed dose distribution calculated by Monte Carlo for a photons beam of 6 MeV emitted by a medical linear accelerator.

  10. [Clinical-pharmacological aspects to accelerate the development process from the preclinical to the clinical phase/2nd communication: promising strategies].

    Science.gov (United States)

    Kuhlmann, Jochen

    2004-01-01

    To improve the transition from research to development a critical evaluation of the individual project by research and disease area teams is required to include input from pharmacology, toxicology, pharmacokinetics, galenics, clinical pharmacology, clinical as well as regulatory experts and marketing. Decisions on the individual development strategy should be made prior to the start of development and all projects should be reviewed at predefined stages throughout the product development life cycle. This ensures consistency of decision-making not only during the development of individual products but throughout the entire development pipeline. Studies in the exploratory stage of drug development should be designed for decision making in contrast to later clinical trials in the confirmatory stage that require power for proof-of-safety and proof-of-efficacy. The more thorough and profound studies have been carried out during this exploratory stage of drug development, the earlier a decision can be made on the continuation or discontinuation of further development, thus saving development time and money and assessing and considerably reducing the risk for the patients and increasing the success rate of the project in the later confirmatory effectiveness trial with an adequate number of subjects receiving the new therapy under typical conditions of use. Strategies which may be helpful to improve the quality of decisions in drug discovery and drug development are: discovery experiments should be done to critically evaluate the compound, the "killer" experiments should be done as early as possible, continuous effort on preclinical disease models is necessary to improve predictability of efficacy in patients ("humanized" research): genomic technology should be used to identify novel, disease-related targets and to characterise preclinical test systems, improvement of knowledge and experience concerning the relevance of new technologies for the clinical picture, genotyping

  11. Linear collider: a preview

    Energy Technology Data Exchange (ETDEWEB)

    Wiedemann, H.

    1981-11-01

    Since no linear colliders have been built yet it is difficult to know at what energy the linear cost scaling of linear colliders drops below the quadratic scaling of storage rings. There is, however, no doubt that a linear collider facility for a center of mass energy above say 500 GeV is significantly cheaper than an equivalent storage ring. In order to make the linear collider principle feasible at very high energies a number of problems have to be solved. There are two kinds of problems: one which is related to the feasibility of the principle and the other kind of problems is associated with minimizing the cost of constructing and operating such a facility. This lecture series describes the problems and possible solutions. Since the real test of a principle requires the construction of a prototype I will in the last chapter describe the SLC project at the Stanford Linear Accelerator Center.

  12. Cosmic particle acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Zimbardo, Gaetano; Perri, Silvia [Universita della Calabria, Dipartimento di Fisica, 87036 Rende (Italy)

    2014-07-01

    The most popular mechanism for the acceleration of cosmic rays, which is thought to operate in supernova remnant shocks as well as at heliospheric shocks, is the diffusive shock acceleration, which is a Fermi mechanism based on normal diffusion. On the other hand, in the last few years it has been shown that the transport of plasma particles in the presence of electric and magnetic turbulence can be superdiffusive rather than normal diffusive. The term 'superdiffusive' refers to the mean square displacement of particle positions growing superlinearly with time, as compared to the normal linear growth. In particular, superdiffusion is characterized by a non Gaussian statistical process called Levy random walk. We show how diffusive shock acceleration is modified by superdiffusion, and how this yields new predictions for the cosmic ray spectral index, for the acceleration time, and for the spatial profile of energetic particles. A comparison with observations of particle acceleration at heliospheric shocks and at supernova remnant shocks is done. We discuss how superdiffusive shock acceleration allows to explain the observations of hard ion spectra at the solar wind termination shock detected by Voyager 2, of hard radio spectra due to synchrotron emission of electrons accelerated at supernova remnant shocks, and how it can help to explain the observations of 'thin rims' in the X-ray synchrotron emission.

  13. Radioprotectors and Radiomitigators for Improving Radiation Therapy: The Small Business Innovation Research (SBIR) Gateway for Accelerating Clinical Translation.

    Science.gov (United States)

    Prasanna, Pataje G S; Narayanan, Deepa; Hallett, Kory; Bernhard, Eric J; Ahmed, Mansoor M; Evans, Gregory; Vikram, Bhadrasain; Weingarten, Michael; Coleman, C Norman

    2015-09-01

    Although radiation therapy is an important cancer treatment modality, patients may experience adverse effects. The use of a radiation-effect modulator may help improve the outcome and health-related quality of life (HRQOL) of patients undergoing radiation therapy either by enhancing tumor cell killing or by protecting normal tissues. Historically, the successful translation of radiation-effect modulators to the clinic has been hindered due to the lack of focused collaboration between academia, pharmaceutical companies and the clinic, along with limited availability of support for such ventures. The U.S. Government has been developing medical countermeasures against accidental and intentional radiation exposures to mitigate the risk and/or severity of acute radiation syndrome (ARS) and the delayed effects of acute radiation exposures (DEARE), and there is now a drug development pipeline established. Some of these medical countermeasures could potentially be repurposed for improving the outcome of radiation therapy and HRQOL of cancer patients. With the objective of developing radiation-effect modulators to improve radiotherapy, the Small Business Innovation Research (SBIR) Development Center at the National Cancer Institute (NCI), supported by the Radiation Research Program (RRP), provided funding to companies from 2011 to 2014 through the SBIR contracts mechanism. Although radiation-effect modulators collectively refer to radioprotectors, radiomitigators and radiosensitizers, the focus of this article is on radioprotection and mitigation of radiation injury. This specific SBIR contract opportunity strengthened existing partnerships and facilitated new collaborations between academia and industry. In this commentary, we assess the impact of this funding opportunity, outline the review process, highlight the organ/site-specific disease needs in the clinic for the development of radiation-effect modulators, provide a general understanding of a framework for gathering

  14. Accelerating Value Creation with Accelerators

    DEFF Research Database (Denmark)

    Jonsson, Eythor Ivar

    2015-01-01

    accelerator programs. Microsoft runs accelerators in seven different countries. Accelerators have grown out of the infancy stage and are now an accepted approach to develop new ventures based on cutting-edge technology like the internet of things, mobile technology, big data and virtual reality. It is also...... with the traditional audit and legal universes and industries are examples of emerging potentials both from a research and business point of view to exploit and explore further. The accelerator approach may therefore be an Idea Watch to consider, no matter which industry you are in, because in essence accelerators...

  15. Accelerating Value Creation with Accelerators

    DEFF Research Database (Denmark)

    Jonsson, Eythor Ivar

    2015-01-01

    Accelerators can help to accelerate value creation. Accelerators are short-term programs that have the objective of creating innovative and fast growing ventures. They have gained attraction as larger corporations like Microsoft, Barclays bank and Nordea bank have initiated and sponsored accelera......Accelerators can help to accelerate value creation. Accelerators are short-term programs that have the objective of creating innovative and fast growing ventures. They have gained attraction as larger corporations like Microsoft, Barclays bank and Nordea bank have initiated and sponsored...... an approach to facilitate implementation and realization of business ideas and is a lucrative approach to transform research into ventures and to revitalize regions and industries in transition. Investors have noticed that the accelerator approach is a way to increase the possibility of success by funnelling...

  16. Optimization of beam transport magnetic field in linear induction accelerator based on genetic algorithm%直线感应加速器输运磁场遗传算法优化

    Institute of Scientific and Technical Information of China (English)

    王强; 赵海龙; 代志勇; 孙文遂; 谢龙; 王文斗

    2013-01-01

    The beam transport system of the Dragon-I linear induction accelerator(LIA) consists of hundreds of solenoid coils and dipole steering coils, which are designed to reduce corkscrew amplitude and transverse motion of electron beam. In order to improve the beam quality, a genetic optimization model of solenoid currents is proposed in this paper and the optimization code GABC based on genetic algorithm and beam transport models is designed, which contains both beam centroid track and the beam envelope model. The matched magnetic field in five blocks of the Dragon- I LIA, including twenty induction acceleration cells and five connection cells, are analyzed using the optimization code. The numerical results reveal that the GABC is effective to solve transport magnetic field optimization problems and could play an important role for beam tuning simulation and experiment.%以直线感应加速器(LIA)匹配磁场设计和束线调谐为背景,提出解决强流相对论电子束长距离、小波动、多元件磁约束的输运优化问题的数值优化办法,建立基于遗传算法的优化程序.结合束质心轨迹及束包络耦合模型,设计描述束传输半径波动大小的评价函数,采用励磁元件馈入电流为优化对象,解决LIA磁场配置“组合爆炸”优化问题.计算结果表明:优化程序可依据不同的初始束流,有针对性地快速给出一组符合束输运要求的励磁电流配置.研究成果为在建的LIA装置束线调谐提供一种重要的数值分析工具.

  17. Building Infrastructure to Accelerate Transfer of Basic Research in Spinal Cord Injury (SCI) to Clinical Practice: North American Clinical Trials Network

    Science.gov (United States)

    2013-08-01

    traumatic acute spinal cord injury from C4 to T12. Most patients were male (83 percent) and had a cervical injury (78 percent). All were treated within 12...Injury Study – will include 350 patients with cervical injuries, the group that seems to benefit most from the drug, at as many as 20 clinical centers... Biomechanical , Anatomical and Neurological Differences between Military and Civilian Injuries and Differences in their Outcomes 5 A list of patients

  18. Application of Ionization Chamber Array in Quality Assurance of Linear Accelerator: X Ray%电离室矩阵用于加速器质量保证:X射线

    Institute of Scientific and Technical Information of China (English)

    杨日增; 卜祥磊; 许志新; 邓晓刚

    2012-01-01

    目的:探讨利用二维电离室矩阵MatriXX进行医用直线加速器质量保证的方法及可靠性.方法:在点剂量的质量保证中,将MatriXX系统在特制水箱中测得的数据与0.6 cc电离室在标准水箱中的剂量测量值作比较,从而定出MatriXX的校准系数,以此来校准射线的输出量和能量.在面剂量的质量保证中,用MatriXX测量医用加速器射线野的对称性、平坦度以及辐射野的大小及中心轴偏离,将测量结果与RFA300三维水箱扫描结果及控制台显示数值进行比较分析.结果:用MatriXX加有机玻璃板可准确快捷地完成对射线输出量和能量的校准.用MatriXX所测射野的对称性和平坦度及射线野大小与RFA300水箱的测量数据一致.结论:MatriXX系统进行加速器的质量保证简便可靠.%Objective: To investigate the method and feasibility of 2D ionization chamber array MatriXX system in quality assurance of linear accelerator. Methods: The outputs and the energy levels irradiated for phonton beams measured by MatriXX in a water phantom specially designed were compared with the data acquired by 0.6 cc ionization chamber with the standard water phantom. The comparison fixed on a correction factor which was used to check the output and energy. The symmetry and flatness and field sizes of the photon beam measured by MatriXX system were compared with the data acquired by RFA300 3D scanner and the digit display of field size showed in the console. Results: The output and the energy level are calibrated accurately and quickly by MatriXX system. The symmetry,flatness and field sizes of the beam measured by MatriXX system are coincident with the data acquired by RFA300 3D scanner and the data showed in the console. Conclusions: The MatriXX system is very convenient and feasible in the quality assurance of linear accelerator.

  19. Linearization Techniques

    Directory of Open Access Journals (Sweden)

    Gildeberto S. Cardoso

    2011-01-01

    Full Text Available This paper presents a study of linear control systems based on exact feedback linearization and approximate feedback linearization. As exact feedback linearization is applied, a linear controller can perform the control objectives. The approximate feedback linearization is required when a nonlinear system presents a noninvolutive property. It uses a Taylor series expansion in order to compute a nonlinear transformation of coordinates to satisfy the involutivity conditions.

  20. RECIRCULATING ACCELERATION

    Energy Technology Data Exchange (ETDEWEB)

    BERG,J.S.; GARREN,A.A.; JOHNSTONE,C.

    2000-04-07

    This paper compares various types of recirculating accelerators, outlining the advantages and disadvantages of various approaches. The accelerators are characterized according to the types of arcs they use: whether there is a single arc for the entire recirculator or there are multiple arcs, and whether the arc(s) are isochronous or non-isochronous.

  1. Accelerators for America's Future

    Science.gov (United States)

    Bai, Mei

    2016-03-01

    Particle accelerator, a powerful tool to energize beams of charged particles to a desired speed and energy, has been the working horse for investigating the fundamental structure of matter and fundermental laws of nature. Most known examples are the 2-mile long Stanford Linear Accelerator at SLAC, the high energy proton and anti-proton collider Tevatron at FermiLab, and Large Hadron Collider that is currently under operation at CERN. During the less than a century development of accelerator science and technology that led to a dazzling list of discoveries, particle accelerators have also found various applications beyond particle and nuclear physics research, and become an indispensible part of the economy. Today, one can find a particle accelerator at almost every corner of our lives, ranging from the x-ray machine at the airport security to radiation diagnostic and therapy in hospitals. This presentation will give a brief introduction of the applications of this powerful tool in fundermental research as well as in industry. Challenges in accelerator science and technology will also be briefly presented

  2. Acute Toxicity Profile and Compliance to Accelerated Radiotherapy Plus Carbogen and Nicotinamide for Clinical Stage T2-4 Laryngeal Cancer: Results of a Phase III Randomized Trial

    Energy Technology Data Exchange (ETDEWEB)

    Janssens, Geert O., E-mail: g.janssens@rther.umcn.nl [Department of Radiation Oncology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Terhaard, Chris H. [Department of Radiation Oncology, University Medical Center Utrecht, Utrecht (Netherlands); Doornaert, Patricia A. [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands); Bijl, Hendrik P. [Department of Radiation Oncology, University Medical Center Groningen, Groningen (Netherlands); Ende, Piet van den [Department of Radiation Oncology, Maastricht University Medical Centre, Maastricht (Netherlands); Chin, Alim [Department of Clinical Oncology, Leiden University Medical Centre, Leiden (Netherlands); Pop, Lucas A.; Kaanders, Johannes H. [Department of Radiation Oncology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)

    2012-02-01

    Purpose: To report the acute toxicity profile and compliance from a randomized Phase III trial comparing accelerated radiotherapy (AR) with accelerated radiotherapy plus carbogen and nicotinamide (ARCON) in laryngeal cancer. Methods and Materials: From April 2001 to February 2008, 345 patients with cT2-4 squamous cell laryngeal cancer were randomized to AR (n = 174) and ARCON (n = 171). Acute toxicity was scored weekly until Week 8 and every 2-4 weeks thereafter. Compliance to carbogen and nicotinamide was reported. Results: Between both treatment arms (AR vs. ARCON) no statistically significant difference was observed for incidence of acute skin reactions (moist desquamation: 56% vs. 58%, p = 0.80), acute mucosal reactions (confluent mucositis: 79% vs. 85%, p = 0.14), and symptoms related to acute mucositis (severe pain on swallowing: 53% vs. 58%, p = 0.37; nasogastric tube feeding: 28% vs. 28%, p = 0.98; narcotic medicines required: 58% vs. 58%, p = 0.97). There was a statistically significant difference in median duration of confluent mucositis in favor of AR (2.0 vs 3.0 weeks, p = 0.01). There was full compliance with carbogen breathing and nicotinamide in 86% and 80% of the patients, with discontinuation in 6% and 12%, respectively. Adjustment of antiemesis prophylaxis was needed in 42% of patients. Conclusion: With the exception of a slight increase in median duration of acute confluent mucositis, the present data reveal a similar acute toxicity profile between both regimens and a good compliance with ARCON for clinical stage T2-4 laryngeal cancers. Treatment outcome and late morbidity will determine the real therapeutic benefit.

  3. Linear Energy Transfer Painting With Proton Therapy: A Means of Reducing Radiation Doses With Equivalent Clinical Effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Fager, Marcus, E-mail: Marcus.Fager@UPHS.UPenn.edu [Department of Radiation Oncology, School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Medical Radiation Physics, Stockholm University, Stockholm (Sweden); Toma-Dasu, Iuliana [Medical Radiation Physics, Stockholm University and Karolinska Institutet, Stockholm (Sweden); Kirk, Maura; Dolney, Derek; Diffenderfer, Eric S.; Vapiwala, Neha [Department of Radiation Oncology, School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Carabe, Alejandro, E-mail: Alejandro.Carabe-Fernandez@UPHS.UPenn.edu [Department of Radiation Oncology, School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (United States)

    2015-04-01

    Purpose: The purpose of this study was to propose a proton treatment planning method that trades physical dose (D) for dose-averaged linear energy transfer (LET{sub d}) while keeping the radiobiologically weighted dose (D{sub RBE}) to the target the same. Methods and Materials: The target is painted with LET{sub d} by using 2, 4, and 7 fields aimed at the proximal segment of the target (split target planning [STP]). As the LET{sub d} within the target increases with increasing number of fields, D decreases to maintain the D{sub RBE} the same as the conventional treatment planning method by using beams treating the full target (full target planning [FTP]). Results: The LET{sub d} increased 61% for 2-field STP (2STP) compared to FTP, 72% for 4STP, and 82% for 7STP inside the target. This increase in LET{sub d} led to a decrease of D with 5.3 ± 0.6 Gy for 2STP, 4.4 ± 0.7 Gy for 4STP, and 5.3 ± 1.1 Gy for 7STP, keeping the DRBE at 90% of the volume (DRBE, 90) constant to FTP. Conclusions: LET{sub d} painting offers a method to reduce prescribed dose at no cost to the biological effectiveness of the treatment.

  4. Young's modulus imaging based on axial and lateral strain estimation from ultrasound data using a clinical linear probe

    Science.gov (United States)

    Said, Ghada; Vray, Didier; Liebgott, Herve; Brusseau, Elisabeth; Basset, Olivier

    2005-04-01

    Strain imaging is useful for visualizing information related to tissue stiffness. However, strain is a parameter that depends on the boundary conditions, tissue connectivity and geometry. As a result, tissue hardness cannot be quantitatively evaluated from the strain distribution. Therefore, reconstruction of the elastic modulus (Young's Modulus) distribution has been investigated for quantitative evaluation of tissue hardness. A method has been recently proposed [NITT 00] to calculate locally the Young's modulus of tissues from the estimations of 3D displacement field within the medium. This approach requires a specific annular ultrasonic probe. The aim of our work, based on Nitta's approach, is to build a Young modulus mapping using clinical ultrasonic equipment. Results from finite-element simulations and a physical phantom are presented.

  5. Linear algebra

    CERN Document Server

    Shilov, Georgi E

    1977-01-01

    Covers determinants, linear spaces, systems of linear equations, linear functions of a vector argument, coordinate transformations, the canonical form of the matrix of a linear operator, bilinear and quadratic forms, Euclidean spaces, unitary spaces, quadratic forms in Euclidean and unitary spaces, finite-dimensional space. Problems with hints and answers.

  6. Photobiomodulation Therapy Improves Performance and Accelerates Recovery of High-Level Rugby Players in Field Test: A Randomized, Crossover, Double-Blind, Placebo-Controlled Clinical Study.

    Science.gov (United States)

    Pinto, Henrique D; Vanin, Adriane A; Miranda, Eduardo F; Tomazoni, Shaiane S; Johnson, Douglas S; Albuquerque-Pontes, Gianna M; Aleixo, Ivo de O; Grandinetti, Vanessa Dos S; Casalechi, Heliodora L; de Carvalho, Paulo de Tarso C; Leal, Ernesto Cesar P

    2016-12-01

    Pinto, HD, Vanin, AA, Miranda, EF, Tomazoni, SS, Johnson, DS, Albuquerque-Pontes, GM, de Oliveira Aleixo Junior, I, Grandinetti, VdS, Casalechi, HL, de Tarso Camillo de Carvalho, P, and Pinto Leal Junior. Photobiomodulation therapy improves performance and accelerates recovery of high-level rugby players in field test: A randomized, crossover, double-blind, placebo-controlled clinical study. J Strength Cond Res 30(12): 3329-3338, 2016-Although growing evidence supports the use of photobiomodulation therapy (PBMT) for performance and recovery enhancement, there have only been laboratory-controlled studies. Therefore, the aim of this study was to analyze the effects of PBMT in performance and recovery of high-level rugby players during an anaerobic field test. Twelve male high-level rugby athletes were recruited in this randomized, crossover, double-blinded, placebo-controlled trial. No interventions were performed before the Bangsbo sprint test (BST) at familiarization phase (week 1); at weeks 2 and 3, pre-exercise PBMT or placebo were randomly applied to each athlete. Photobiomodulation therapy irradiation was performed at 17 sites of each lower limb, employing a cluster with 12 diodes (4 laser diodes of 905 nm, 4 light emitting diodes [LEDs] of 875 nm, and 4 LEDs of 640 nm, 30 J per site, manufactured by Multi Radiance Medical). Average time of sprints, best time of sprints, and fatigue index were obtained from BST. Blood lactate levels were assessed at baseline, and at 3, 10, 30, and 60 minutes after BST. Athletes' perceived fatigue was also assessed through a questionnaire. Photobiomodulation therapy significantly (p ≤ 0.05) improved the average time of sprints and fatigue index in BST. Photobiomodulation therapy significantly decreased percentage of change in blood lactate levels (p ≤ 0.05) and perceived fatigue (p ≤ 0.05). Pre-exercise PBMT with the combination of super-pulsed laser (low-level laser), red LEDs, and infrared LEDs can enhance performance

  7. Measurement of the dosimetric parameters for low monitor units in step-and-shoot IMRT delivered by Siemens Artiste linear accelerators; Medida de los parametros dosimetricos para bajo numero de unidades monitor en IMRT segmentada estatica administrada por aceleradores lineales Siemens Artiste

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Rodriguez, C.; Lopez Fernandez, A.; Saez Beltran, M.; Martin Martin, G.; Alonso Iracheta, L.

    2012-07-01

    Absorbed dose linearity and beam stability, both for low monitor units, are important factors for ensuring planned dose delivery in step-and-shoot IMRT. For Siemens Artiste linear accelerators, under IMRT stable irradiation conditions and for a single segment of 20 cm x 20 cm field size, the linearity of the absorbed dose with the monitor units, field flatness and symmetry have been measured for the range between 1 and 10 monitor units. We have found that absorbed dose linearity with monitor units is within 2% down to 2 monitor units and it is about 9% for 1 monitor unit. Flatness and symmetry values show variations within 1% down to 2 monitor units and increase by 9% for lower values. Using our monitor unit distribution per segment in IMRT we estimate that the uncertainty in absorbed dose for a whole treatment due to these factors is less than 1% (k= 3). (Author) 13 refs.

  8. Horizontal Accelerator

    Data.gov (United States)

    Federal Laboratory Consortium — The Horizontal Accelerator (HA) Facility is a versatile research tool available for use on projects requiring simulation of the crash environment. The HA Facility is...

  9. Clinical Outcomes of Small Incision Lenticule Extraction with Accelerated Cross-Linking (ReLEx SMILE Xtra in Patients with Thin Corneas and Borderline Topography

    Directory of Open Access Journals (Sweden)

    Sri Ganesh

    2015-01-01

    Full Text Available Purpose. To study the safety and clinical outcomes of ReLEx SMILE with accelerated cross-linking in individuals with thinner corneas, borderline topography, and higher refractive errors. Methods. Eligible patients first underwent SMILE procedure for correction of myopic refractive error. Following the removal of lenticule, 0.25% riboflavin in saline was injected into the interface and allowed to diffuse for 60 seconds. Finally, eye was exposed to UV-A radiation of 45 mW/cm2 for 75 seconds through the cap. Total energy delivered was 3.4 J/cm2. Results. 40 eyes of 20 patients with mean age of 26.75 ± 5.99 years were treated. Mean follow-up was 12 months ± 28.12 days. Mean spherical equivalent (SE was −5.02 ± 2.06 D preoperatively and −0.24 ± 0.18 D postoperatively. The mean central corneal thickness (CCT and keratometry changed from 501 ± 25.90 µm to 415 ± 42.26 µm and 45.40 ± 1.40 D to 41.2 ± 2.75 D, respectively. Mean uncorrected visual acuity (UCVA was 20/25 or better in all eyes. No eyes lost lines of corrected distant visual acuity (CDVA. There were no complications like haze, keratitis, ectasia, or regression. Conclusion. Based on the initial clinical outcome it appears that SMILE Xtra may be a safe and feasible modality to prevent corneal ectasia in susceptible individuals.

  10. THE USE OF SUPEROXIDE DISMUTASE IN ACCELERATING SYMPTOM RELIEF IN ASTHMATIC AND HOUSE DUST MITE ALLERGIC CHILDREN RECEIVING HOUSE DUST MITE IMMUNOTHERAPY: DOUBLE BLIND RANDOMIZED CONTROLLED CLINICAL TRIAL

    Directory of Open Access Journals (Sweden)

    Anang Endaryanto

    2015-09-01

    Full Text Available Objective: To evaluate the efficacy of superoxide dismutase (SOD in lung function (FEV1 reversibility and respiratory symptoms (drug scores, symptoms scores in asthmatic and house dust mite allergic children receiving house dust mites immunotherapy. Methods: Forty subjects aged 6–17 years old with asthma, tested positive for house dust mite allergy on skin prick test, and received immunotherapy were enrolled in this study. All subjects completed clinical based assessments and diary-based assessments for drug and symptom scores. Following a four-week baseline assessment, all subjects were randomized to receive SOD or placebo. Respiratory symptoms (drug and symptoms score and FEV1 were evaluated at the end of the 1st, 2nd, 3rd, and 4th weeks after randomization. Drug score, symptoms score, and FEV1 reversibility test results were analyzed using a Paired t test and repeated measure of ANOVA. Results: There was a significant difference in drug scores, symptoms score, and FEV1 reversibility test outcomes between SOD and placebo. SOD group showed a significant decrease in all outcome measures compared to those in placebo group. Conclusions: The use of SOD as antioxidants is effective in accelerating symptom relief for children with asthma and house dust mite allergy receiving house dust mite immunotherapy.

  11. Medical Linear Accelerator Radiation Safety and Occupational Safety Management of the Implementation of the Thinking Path%医用直线加速器放射安全问题与职业安全管理的实施路径探讨

    Institute of Scientific and Technical Information of China (English)

    马琰

    2015-01-01

    Output in the process of medical linear accelerator in the treatment of running ray energy is larger, at the same time, the equipment in the running process will produce other electromagnetic radiation, the radiation can cause harm to people's health, this requires that the hospital can to do a good job of radiation protection in the process of equipment oper-ation, reduce the radiation damage. This article through to the medical linear accelerator radiation characteristics were stud-ied, and analyzed the medical linear accelerator radiation hazard, and put forward the countermeasures, hoping to provide beneficial for the research on medical linear accelerator radiation safety problems.%医用直线加速器在治疗运行过程中输出的射线能量比较大,与此同时,设备在运行过程中会产生其他的电磁辐射,这些辐射会对人们的身体健康造成伤害,这就需要医院在设备运行过程中能够做好防辐射工作,减少辐射伤害现象的发生。该文通过对医用直线加速器的放射特征进行研究,并分析了医用直线加速器的辐射危害,还提出了应对措施,希望能够为医用直线加速器放射安全问题研究提供有益借鉴。

  12. Particle acceleration around SNR shocks

    Energy Technology Data Exchange (ETDEWEB)

    Morlino, G., E-mail: morlino@arcetri.astro.it [INAF-Osservatorio Astrofisico di Arcetri, Largo E. Fermi, 5, 50125 Firenze (Italy)

    2013-08-21

    We review the basic features of particle acceleration theory around collisionless shocks in supernova remnants (SNRs). We show how non-linear effects induced by the back reaction of accelerated particles onto the shock dynamics are of paramount importance to support the hipotesys that SNRs are the factories of Galactic cosmic rays. Recent developments in the modeling of the mechanism of diffusive shock acceleration are discussed, with emphasis on the role of magnetic field amplification and the presence of neutrals in the circumstellar environment. Special attention will be devoted to observational consequences of non-linear effects on the multi-wavelength spectrum of SNRs, with emphasis on X-ray and gamma-ray emission. Finally we also discuss how Balmer lines, detected from several young SNRs, can be used to estimate the shock dynamical properties and the efficiency of CR acceleration.

  13. Particle acceleration around SNR shocks

    CERN Document Server

    Morlino, Giovanni

    2012-01-01

    We review the basic features of particle acceleration theory around collisionless shocks in supernova remnants (SNRs). We show how non linear effects induced by the back reaction of accelerated particles onto the shock dynamics are of paramount importance to support the hipotesys that SNRs are the factories of Galactic cosmic rays. Recent developments in the modeling of the mechanism of diffusive shock acceleration are discussed, with emphasis on the role of magnetic field amplification and the presence of neutrals in the circumstellar environment. Special attention will be devoted to observational consequences of non linear effects on the multi-wavelength spectrum of SNRs, with emphasis on X-ray and gamma-ray emission. Finally we also discuss how Balmer lines, detected from several young SNRs, can be used to estimate the shock dynamical properties and the efficiency of CR acceleration.

  14. Acute toxicity profile and compliance to accelerated radiotherapy plus carbogen and nicotinamide for clinical stage T2-4 laryngeal cancer: results of a phase III randomized trial.

    NARCIS (Netherlands)

    Janssens, G.O.R.J.; Terhaard, C.H.J.; Doornaert, P.A.; Bijl, H.P.; Ende, P. van den; Chin, A.; Pop, L.A.M.; Kaanders, J.H.A.M.

    2012-01-01

    PURPOSE: To report the acute toxicity profile and compliance from a randomized Phase III trial comparing accelerated radiotherapy (AR) with accelerated radiotherapy plus carbogen and nicotinamide (ARCON) in laryngeal cancer. METHODS AND MATERIALS: From April 2001 to February 2008, 345 patients with

  15. ACUTE TOXICITY PROFILE AND COMPLIANCE TO ACCELERATED RADIOTHERAPY PLUS CARBOGEN AND NICOTINAMIDE FOR CLINICAL STAGE T2-4 LARYNGEAL CANCER : RESULTS OF A PHASE III RANDOMIZED TRIAL

    NARCIS (Netherlands)

    Janssens, Geert O.; Terhaard, Chris H.; Doornaert, Patricia A.; Bijl, Hendrik P.; van den Ende, Piet; Chin, Alim; Pop, Lucas A.; Kaanders, Johannes H.

    2012-01-01

    Purpose: To report the acute toxicity profile and compliance from a randomized Phase III trial comparing accelerated radiotherapy (AR) with accelerated radiotherapy plus carbogen and nicotinamide (ARCON) in laryngeal cancer. Methods and Materials: From April 2001 to February 2008, 345 patients with

  16. Accelerator applications in energy and security

    CERN Document Server

    Chou, Weiren

    2015-01-01

    As accelerator science and technology progressed over the past several decades, the accelerators themselves have undergone major improvements in multiple performance factors: beam energy, beam power, and beam brightness. As a consequence, accelerators have found applications in a wide range of fields in our life and in our society. The current volume is dedicated to applications in energy and security, two of the most important and urgent topics in today's world. This volume makes an effort to provide a review as complete and up to date as possible of this broad and challenging subject. It contains overviews on each of the two topics and a series of articles for in-depth discussions including heavy ion accelerator driven inertial fusion, linear accelerator-based ADS systems, circular accelerator-based ADS systems, accelerator-reactor interface, accelerators for fusion material testing, cargo inspection, proton radiography, compact neutron generators and detectors. It also has a review article on accelerator ...

  17. Clinical manifestation and histopathologic features of linear cutaneous lupus erythematosus: a report of six cases%线状皮肤型红斑狼疮六例

    Institute of Scientific and Technical Information of China (English)

    罗燕; 李晓建; 黄琼

    2010-01-01

    Objective To summariza the clinical and histological features of linear cutaneous lupus erythematosus (LCLE).Methods Six cases of LCLE were analyzed retrospectively.Results LCLE was often clinically characterized by unilateral.zonal or linear,dark-erythematous patches with telangiectasia,and some lesions were covered with adherent Scales.Histologically,there were patchy perivascular and periadnexal lymphoid inflammatory infiltrate occurring in the superficial and deep dermis.Some cases were pathologically manifested by parakeratosis of superficial dermis,follicular plugging and hydropic degeneration of the basal layer of the epidermis,which was characteristic of discoid lupus erythematosus.The preferred treatment was chloroquine for LCLE.Low dose of corticosteroids were recommended for widespread lesions,especially for those pathologically manifested by lymphocyte infiltrates in the lower dermis and fat tissue.Conclusion The diagnosis of LCLE should be based on clinical and histopathological manifestations.%目的 探讨线状皮肤型红斑狼疮(LCLE)临床和组织病理学特点.方法 回顾分析6例LCLE的临床和病理学特点.结果 LCLE多单侧发病,表现为带状或线状分布的暗红斑,伴毛细血管增生扩张,部分黏着性鳞屑.组织病理学诊断依据为真皮浅、深丛细血管周围及毛囊、皮脂腺、汗腺周围有致密团块状淋巴细胞浸润,部分病例可见表皮角化不全,毛囊角栓,基底细胞液化变性,类似盘状红斑狼疮组织像.治疗以氯喹为首选,对于皮疹范围较广泛,且组织病理改变见淋巴细胞浸润达真皮深部甚至皮下脂肪小叶处的患者,给予小剂量糖皮质激素治疗疗效明显.结论 LCLE诊断需要结合临床和组织病理.

  18. Accelerated Unification

    OpenAIRE

    Arkani-Hamed, Nima; Cohen, Andrew; Georgi, Howard

    2001-01-01

    We construct four dimensional gauge theories in which the successful supersymmetric unification of gauge couplings is preserved but accelerated by N-fold replication of the MSSM gauge and Higgs structure. This results in a low unification scale of $10^{13/N}$ TeV.

  19. The Spallation Neutron Source accelerator system design

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, S., E-mail: stuarth@fnal.gov [Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831 (United States); Abraham, W. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Aleksandrov, A. [Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831 (United States); Allen, C. [Techsource, Inc., 1475 Central Avenue, Suite 250, Los Alamos, NM 87544-3291 (United States); Alonso, J. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Anderson, D. [Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831 (United States); Arenius, D. [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Avenue, Newport News, VA 23606 (United States); Arthur, T. [Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831 (United States); Assadi, S. [Techsource, Inc., 1475 Central Avenue, Suite 250, Los Alamos, NM 87544-3291 (United States); Ayers, J.; Bach, P. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Badea, V. [Brookhaven National Laboratory, P.O. Box 5000, Upton, NY 11973-5000 (United States); Battle, R. [Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831 (United States); Beebe-Wang, J. [Brookhaven National Laboratory, P.O. Box 5000, Upton, NY 11973-5000 (United States); Bergmann, B.; Bernardin, J.; Bhatia, T.; Billen, J.; Birke, T.; Bjorklund, E. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); and others

    2014-11-01

    The Spallation Neutron Source (SNS) was designed and constructed by a collaboration of six U.S. Department of Energy national laboratories. The SNS accelerator system consists of a 1 GeV linear accelerator and an accumulator ring providing 1.4 MW of proton beam power in microsecond-long beam pulses to a liquid mercury target for neutron production. The accelerator complex consists of a front-end negative hydrogen-ion injector system, an 87 MeV drift tube linear accelerator, a 186 MeV side-coupled linear accelerator, a 1 GeV superconducting linear accelerator, a 248-m circumference accumulator ring and associated beam transport lines. The accelerator complex is supported by ∼100 high-power RF power systems, a 2 K cryogenic plant, ∼400 DC and pulsed power supply systems, ∼400 beam diagnostic devices and a distributed control system handling ∼100,000 I/O signals. The beam dynamics design of the SNS accelerator is presented, as is the engineering design of the major accelerator subsystems.

  20. The Spallation Neutron Source accelerator system design

    Science.gov (United States)

    Henderson, S.; Abraham, W.; Aleksandrov, A.; Allen, C.; Alonso, J.; Anderson, D.; Arenius, D.; Arthur, T.; Assadi, S.; Ayers, J.; Bach, P.; Badea, V.; Battle, R.; Beebe-Wang, J.; Bergmann, B.; Bernardin, J.; Bhatia, T.; Billen, J.; Birke, T.; Bjorklund, E.; Blaskiewicz, M.; Blind, B.; Blokland, W.; Bookwalter, V.; Borovina, D.; Bowling, S.; Bradley, J.; Brantley, C.; Brennan, J.; Brodowski, J.; Brown, S.; Brown, R.; Bruce, D.; Bultman, N.; Cameron, P.; Campisi, I.; Casagrande, F.; Catalan-Lasheras, N.; Champion, M.; Champion, M.; Chen, Z.; Cheng, D.; Cho, Y.; Christensen, K.; Chu, C.; Cleaves, J.; Connolly, R.; Cote, T.; Cousineau, S.; Crandall, K.; Creel, J.; Crofford, M.; Cull, P.; Cutler, R.; Dabney, R.; Dalesio, L.; Daly, E.; Damm, R.; Danilov, V.; Davino, D.; Davis, K.; Dawson, C.; Day, L.; Deibele, C.; Delayen, J.; DeLong, J.; Demello, A.; DeVan, W.; Digennaro, R.; Dixon, K.; Dodson, G.; Doleans, M.; Doolittle, L.; Doss, J.; Drury, M.; Elliot, T.; Ellis, S.; Error, J.; Fazekas, J.; Fedotov, A.; Feng, P.; Fischer, J.; Fox, W.; Fuja, R.; Funk, W.; Galambos, J.; Ganni, V.; Garnett, R.; Geng, X.; Gentzlinger, R.; Giannella, M.; Gibson, P.; Gillis, R.; Gioia, J.; Gordon, J.; Gough, R.; Greer, J.; Gregory, W.; Gribble, R.; Grice, W.; Gurd, D.; Gurd, P.; Guthrie, A.; Hahn, H.; Hardek, T.; Hardekopf, R.; Harrison, J.; Hatfield, D.; He, P.; Hechler, M.; Heistermann, F.; Helus, S.; Hiatt, T.; Hicks, S.; Hill, J.; Hill, J.; Hoff, L.; Hoff, M.; Hogan, J.; Holding, M.; Holik, P.; Holmes, J.; Holtkamp, N.; Hovater, C.; Howell, M.; Hseuh, H.; Huhn, A.; Hunter, T.; Ilg, T.; Jackson, J.; Jain, A.; Jason, A.; Jeon, D.; Johnson, G.; Jones, A.; Joseph, S.; Justice, A.; Kang, Y.; Kasemir, K.; Keller, R.; Kersevan, R.; Kerstiens, D.; Kesselman, M.; Kim, S.; Kneisel, P.; Kravchuk, L.; Kuneli, T.; Kurennoy, S.; Kustom, R.; Kwon, S.; Ladd, P.; Lambiase, R.; Lee, Y. Y.; Leitner, M.; Leung, K.-N.; Lewis, S.; Liaw, C.; Lionberger, C.; Lo, C. C.; Long, C.; Ludewig, H.; Ludvig, J.; Luft, P.; Lynch, M.; Ma, H.; MacGill, R.; Macha, K.; Madre, B.; Mahler, G.; Mahoney, K.; Maines, J.; Mammosser, J.; Mann, T.; Marneris, I.; Marroquin, P.; Martineau, R.; Matsumoto, K.; McCarthy, M.; McChesney, C.; McGahern, W.; McGehee, P.; Meng, W.; Merz, B.; Meyer, R.; Meyer, R.; Miller, B.; Mitchell, R.; Mize, J.; Monroy, M.; Munro, J.; Murdoch, G.; Musson, J.; Nath, S.; Nelson, R.; Nelson, R.; O`Hara, J.; Olsen, D.; Oren, W.; Oshatz, D.; Owens, T.; Pai, C.; Papaphilippou, I.; Patterson, N.; Patterson, J.; Pearson, C.; Pelaia, T.; Pieck, M.; Piller, C.; Plawski, T.; Plum, M.; Pogge, J.; Power, J.; Powers, T.; Preble, J.; Prokop, M.; Pruyn, J.; Purcell, D.; Rank, J.; Raparia, D.; Ratti, A.; Reass, W.; Reece, K.; Rees, D.; Regan, A.; Regis, M.; Reijonen, J.; Rej, D.; Richards, D.; Richied, D.; Rode, C.; Rodriguez, W.; Rodriguez, M.; Rohlev, A.; Rose, C.; Roseberry, T.; Rowton, L.; Roybal, W.; Rust, K.; Salazer, G.; Sandberg, J.; Saunders, J.; Schenkel, T.; Schneider, W.; Schrage, D.; Schubert, J.; Severino, F.; Shafer, R.; Shea, T.; Shishlo, A.; Shoaee, H.; Sibley, C.; Sims, J.; Smee, S.; Smith, J.; Smith, K.; Spitz, R.; Staples, J.; Stein, P.; Stettler, M.; Stirbet, M.; Stockli, M.; Stone, W.; Stout, D.; Stovall, J.; Strelo, W.; Strong, H.; Sundelin, R.; Syversrud, D.; Szajbler, M.; Takeda, H.; Tallerico, P.; Tang, J.; Tanke, E.; Tepikian, S.; Thomae, R.; Thompson, D.; Thomson, D.; Thuot, M.; Treml, C.; Tsoupas, N.; Tuozzolo, J.; Tuzel, W.; Vassioutchenko, A.; Virostek, S.; Wallig, J.; Wanderer, P.; Wang, Y.; Wang, J. G.; Wangler, T.; Warren, D.; Wei, J.; Weiss, D.; Welton, R.; Weng, J.; Weng, W.-T.; Wezensky, M.; White, M.; Whitlatch, T.; Williams, D.; Williams, E.; Wilson, K.; Wiseman, M.; Wood, R.; Wright, P.; Wu, A.; Ybarrolaza, N.; Young, K.; Young, L.; Yourd, R.; Zachoszcz, A.; Zaltsman, A.; Zhang, S.; Zhang, W.; Zhang, Y.; Zhukov, A.

    2014-11-01

    The Spallation Neutron Source (SNS) was designed and constructed by a collaboration of six U.S. Department of Energy national laboratories. The SNS accelerator system consists of a 1 GeV linear accelerator and an accumulator ring providing 1.4 MW of proton beam power in microsecond-long beam pulses to a liquid mercury target for neutron production. The accelerator complex consists of a front-end negative hydrogen-ion injector system, an 87 MeV drift tube linear accelerator, a 186 MeV side-coupled linear accelerator, a 1 GeV superconducting linear accelerator, a 248-m circumference accumulator ring and associated beam transport lines. The accelerator complex is supported by ~100 high-power RF power systems, a 2 K cryogenic plant, ~400 DC and pulsed power supply systems, ~400 beam diagnostic devices and a distributed control system handling ~100,000 I/O signals. The beam dynamics design of the SNS accelerator is presented, as is the engineering design of the major accelerator subsystems.

  1. Particle Accelerators in China

    Science.gov (United States)

    Zhang, Chuang; Fang, Shouxian

    As the special machines that can accelerate charged particle beams to high energy by using electromagnetic fields, particle accelerators have been widely applied in scientific research and various areas of society. The development of particle accelerators in China started in the early 1950s. After a brief review of the history of accelerators, this article describes in the following sections: particle colliders, heavy-ion accelerators, high-intensity proton accelerators, accelerator-based light sources, pulsed power accelerators, small scale accelerators, accelerators for applications, accelerator technology development and advanced accelerator concepts. The prospects of particle accelerators in China are also presented.

  2. Performance of the digene LQ, RH and PS HPVs genotyping systems on clinical samples and comparison with HC2 and PCR-based Linear Array

    Directory of Open Access Journals (Sweden)

    Godínez Jose M

    2011-11-01

    Full Text Available Abstract Background Certain Human Papillomaviruses (HPVs are the infectious agents involved in cervical cancer development. Detection of HPVs DNA is part of the cervical cancer screening protocols and HPVs genotyping has been proposed for its inclusion in these preventive programs. The aim of this study was to evaluate three novel genotyping tests, namely Qiagen LQ, RH and PS, in clinical samples with and without abnormalities. For this, 305 cervical samples were processed and the results of the evaluated techniques were compared with those obtained in the HPVs diagnostic process in our lab, by using HC2 and Linear Array (LA technologies. Results The concordances and kappa statistics (k for each technique compared with HC2 were 98.69% (k = 0.94 for LQ, 98.03% (k = 0.91 for RH and 91.80% (k = 0.82 for PS. There was a very good agreement in HPVs type-specific concordance for the most prevalent types HPV16 (kappa range = 0.83-0.90, HPV18 (k.r.= 0.74-0.80 and HPV45 (k.r.= 0.82-0.90. Conclusions The three tests showed an overall good concordance for HPVs detection when compared with HR-HC2 system. LQ and RH rendered lower detection rate for multiple infections than LA genotyping. However, our understanding of the clinical significance of multiple HPVs infections is still incomplete and therefore the relevance of the lower ability to detect multiple infections needs to be evaluated.

  3. MUON ACCELERATION

    Energy Technology Data Exchange (ETDEWEB)

    BERG,S.J.

    2003-11-18

    One of the major motivations driving recent interest in FFAGs is their use for the cost-effective acceleration of muons. This paper summarizes the progress in this area that was achieved leading up to and at the FFAG workshop at KEK from July 7-12, 2003. Much of the relevant background and references are also given here, to give a context to the progress we have made.

  4. Linear Systems.

    Science.gov (United States)

    The report documents a series of seminars at Rome Air Development Center with the content equivalent to an intense course in Linear Systems . Material...is slanted toward the practicing engineer and introduces some of the fundamental concepts and techniques for analyzing linear systems . Techniques for

  5. Laser acceleration

    Science.gov (United States)

    Tajima, T.; Nakajima, K.; Mourou, G.

    2017-02-01

    The fundamental idea of Laser Wakefield Acceleration (LWFA) is reviewed. An ultrafast intense laser pulse drives coherent wakefield with a relativistic amplitude robustly supported by the plasma. While the large amplitude of wakefields involves collective resonant oscillations of the eigenmode of the entire plasma electrons, the wake phase velocity ˜ c and ultrafastness of the laser pulse introduce the wake stability and rigidity. A large number of worldwide experiments show a rapid progress of this concept realization toward both the high-energy accelerator prospect and broad applications. The strong interest in this has been spurring and stimulating novel laser technologies, including the Chirped Pulse Amplification, the Thin Film Compression, the Coherent Amplification Network, and the Relativistic Mirror Compression. These in turn have created a conglomerate of novel science and technology with LWFA to form a new genre of high field science with many parameters of merit in this field increasing exponentially lately. This science has triggered a number of worldwide research centers and initiatives. Associated physics of ion acceleration, X-ray generation, and astrophysical processes of ultrahigh energy cosmic rays are reviewed. Applications such as X-ray free electron laser, cancer therapy, and radioisotope production etc. are considered. A new avenue of LWFA using nanomaterials is also emerging.

  6. Accelerating abelian gauge dynamics

    CERN Document Server

    Adler, Stephen Louis

    1991-01-01

    In this paper, we suggest a new acceleration method for Abelian gauge theories based on linear transformations to variables which weight all length scales equally. We measure the autocorrelation time for the Polyakov loop and the plaquette at β=1.0 in the U(1) gauge theory in four dimensions, for the new method and for standard Metropolis updates. We find a dramatic improvement for the new method over the Metropolis method. Computing the critical exponent z for the new method remains an important open issue.

  7. Blind evaluation of the microwave-accelerated metal-enhanced fluorescence ultrarapid and sensitive Chlamydia trachomatis test by use of clinical samp