WorldWideScience

Sample records for clinical image mri

  1. Virtual phantom magnetic resonance imaging (ViP MRI) on a clinical MRI platform.

    Science.gov (United States)

    Saint-Jalmes, Hervé; Bordelois, Alejandro; Gambarota, Giulio

    2018-01-01

    The purpose of this study was to implement Virtual Phantom Magnetic Resonance Imaging (ViP MRI), a technique that allows for generating reference signals in MR images using radiofrequency (RF) signals, on a clinical MR system and to test newly designed virtual phantoms. MRI experiments were conducted on a 1.5 T MRI scanner. Electromagnetic modelling of the ViP system was done using the principle of reciprocity. The ViP RF signals were generated using a compact waveform generator (dimensions of 26 cm × 18 cm × 16 cm), connected to a homebuilt 25 mm-diameter RF coil. The ViP RF signals were transmitted to the MRI scanner bore, simultaneously with the acquisition of the signal from the object of interest. Different types of MRI data acquisition (2D and 3D gradient-echo) as well as different phantoms, including the Shepp-Logan phantom, were tested. Furthermore, a uniquely designed virtual phantom - in the shape of a grid - was generated; this newly proposed phantom allows for the investigations of the vendor distortion correction field. High quality MR images of virtual phantoms were obtained. An excellent agreement was found between the experimental data and the inverse cube law, which was the expected functional dependence obtained from the electromagnetic modelling of the ViP system. Short-term time stability measurements yielded a coefficient of variation in the signal intensity over time equal to 0.23% and 0.13% for virtual and physical phantom, respectively. MR images of the virtual grid-shaped phantom were reconstructed with the vendor distortion correction; this allowed for a direct visualization of the vendor distortion correction field. Furthermore, as expected from the electromagnetic modelling of the ViP system, a very compact coil (diameter ~ cm) and very small currents (intensity ~ mA) were sufficient to generate a signal comparable to that of physical phantoms in MRI experiments. The ViP MRI technique was successfully implemented on a clinical MR

  2. Small animal MRI: clinical MRI as an interface to basic biomedical research

    International Nuclear Information System (INIS)

    Pinkernelle, J.G.; Stelter, L.; Hamm, B.; Teichgraeber, U.

    2008-01-01

    The demand for highly resolved small animal MRI for the purpose of biomedical research has increased constantly. Dedicated small animal MRI scanners working at ultra high field strengths from 4.7 to 7.0 T and even above are MRI at its best. However, using high resolution RF coils in clinical scanners up to 3.0 T, small animal MRI can achieve highly resolved images showing excellent tissue contrast. In fact, in abundant experimental studies, clinical MRI is used for small animal imaging. Mostly clinical RF coils in the single-loop design are applied. In addition, custom-built RF coils and even gradient inserts are used in a clinical scanner. For the reduction of moving artifacts, special MRI-compatible animal ECG und respiration devices are available. In conclusion, clinical devices offer broad availability, are less expense in combination with good imaging performance and provide a translational nature of imaging results. (orig.)

  3. Usefulness and limitation of functional MRI with echo planar imaging using clinical MR apparatus

    International Nuclear Information System (INIS)

    Kusunoki, Katsusuke; Zenke, Kiichiro; Saito, Masahiro; Sadamoto, Kazuhiko; Ohue, Shiro; Sakaki, Saburo; Kumon, Yoshiaki; Kabasawa, Hiroyuki; Nagasawa, Kiyoshi

    1998-01-01

    We studied blood oxygen level-dependent (BOLD) functional MRI (fMRI) with EPI sequence in 21 normal volunteers and 8 presurgical clinical patients using a 1.5 T clinical MRI apparatus. To optimize the imaging parameters, we compared the fMRI images obtained by GFE-EPI and by SE-EPI in normal volunteers while each squeezed a sponge ball. We identified the motor cortex in 85.7% of normal volunteers by GFE-EPI in contrast to only 28.6% by SE-EPI. In addition, our clinical MR apparatus, using optimized parameters, maximally provides 15 slices per 5 seconds. In patients with brain tumor close to the sensorimotor cortex, we attempted to identify the motor cortex preoperatively by this procedure and found a significant increase of signal intensity in the motor cortex in 5 of 8 patients. In conclusion, fMRI using EPI may be useful for identifying the motor cortex preoperatively. However, further development of the apparatus is needed to obtain better temporal and spatial resolution for clinical applications. (author)

  4. IClinfMRI Software for Integrating Functional MRI Techniques in Presurgical Mapping and Clinical Studies.

    Science.gov (United States)

    Hsu, Ai-Ling; Hou, Ping; Johnson, Jason M; Wu, Changwei W; Noll, Kyle R; Prabhu, Sujit S; Ferguson, Sherise D; Kumar, Vinodh A; Schomer, Donald F; Hazle, John D; Chen, Jyh-Horng; Liu, Ho-Ling

    2018-01-01

    Task-evoked and resting-state (rs) functional magnetic resonance imaging (fMRI) techniques have been applied to the clinical management of neurological diseases, exemplified by presurgical localization of eloquent cortex, to assist neurosurgeons in maximizing resection while preserving brain functions. In addition, recent studies have recommended incorporating cerebrovascular reactivity (CVR) imaging into clinical fMRI to evaluate the risk of lesion-induced neurovascular uncoupling (NVU). Although each of these imaging techniques possesses its own advantage for presurgical mapping, a specialized clinical software that integrates the three complementary techniques and promptly outputs the analyzed results to radiology and surgical navigation systems in a clinical format is still lacking. We developed the Integrated fMRI for Clinical Research (IClinfMRI) software to facilitate these needs. Beyond the independent processing of task-fMRI, rs-fMRI, and CVR mapping, IClinfMRI encompasses three unique functions: (1) supporting the interactive rs-fMRI mapping while visualizing task-fMRI results (or results from published meta-analysis) as a guidance map, (2) indicating/visualizing the NVU potential on analyzed fMRI maps, and (3) exporting these advanced mapping results in a Digital Imaging and Communications in Medicine (DICOM) format that are ready to export to a picture archiving and communication system (PACS) and a surgical navigation system. In summary, IClinfMRI has the merits of efficiently translating and integrating state-of-the-art imaging techniques for presurgical functional mapping and clinical fMRI studies.

  5. PET-MRI and multimodal cancer imaging

    International Nuclear Information System (INIS)

    Wang Taisong; Zhao Jinhua; Song Jianhua

    2011-01-01

    Multimodality imaging, specifically PET-CT, brought a new perspective into the fields of clinical imaging. Clinical cases have shown that PET-CT has great value in clinical diagnosis and experimental research. But PET-CT still bears some limitations. A major drawback is that CT provides only limited soft tissue contrast and exposes the patient to a significant radiation dose. MRI overcome these limitations, it has excellent soft tissue contrast, high temporal and spatial resolution and no radiation damage. Additionally, since MRI provides also functional information, PET-MRI will show a new direction of multimodality imaging in the future. (authors)

  6. fMRI. Basics and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Ulmer, Stephan; Jansen, Olav (eds.) [University Hospital of Schleswig-Holstein, Kiel (Germany). Inst. of Neuroradiology, Neurocenter

    2010-07-01

    Functional MRI (fMRI) and the basic method of BOLD imaging were introduced in 1993 by Seiji Ogawa. From very basic experiments, fMRI has evolved into a clinical application for daily routine brain imaging. There have been various improvements in both the imaging technique as such as well as in the statistical analysis. In this volume, experts in the field share their knowledge and point out possible technical barriers and problems explaining how to solve them. Starting from the very basics on the origin of the BOLD signal, the book covers technical issues, anatomical landmarks, presurgical applications, and special issues in various clinical fields. Other modalities for brain mapping such as PET, TMS, and MEG are also compared with fMRI. This book is intended to give a state-of-the-art overview and to serve as a reference and guide for clinical applications of fMRI. (orig.)

  7. Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI

    DEFF Research Database (Denmark)

    Keller, Sune H; Holm, Søren; Hansen, Adam E

    2013-01-01

    Integrated whole-body PET/MRI tomographs have become available. PET/MR imaging has the potential to supplement, or even replace combined PET/CT imaging in selected clinical indications. However, this is true only if methodological pitfalls and image artifacts arising from novel MR-based attenuation...

  8. Clinical use of digital retrospective image fusion of CT, MRI, FDG-PET and SPECT - fields of indications and results

    International Nuclear Information System (INIS)

    Lemke, A.J.; Niehues, S.M.; Amthauer, H.; Felix, R.; Rohlfing, T.; Hosten, N.

    2004-01-01

    Purpose: To evaluate the feasibility and the clinical benefits of retrospective digital image fusion (PET, SPECT, CT and MRI). Materials and methods: In a prospective study, a total of 273 image fusions were performed and evaluated. The underlying image acquisitions (CT, MRI, SPECT and PET) were performed in a way appropriate for the respective clinical question and anatomical region. Image fusion was executed with a software program developed during this study. The results of the image fusion procedure were evaluated in terms of technical feasibility, clinical objective, and therapeutic impact. Results: The most frequent combinations of modalities were CT/PET (n = 156) and MRI/PET (n = 59), followed by MRI/SPECT (n = 28), CT/SPECT (n = 22) and CT/MRI (n = 8). The clinical questions included following regions (more than one region per case possible): neurocranium (n = 42), neck (n = 13), lung and mediastinum (n = 24), abdomen (n = 181), and pelvis (n = 65). In 92.6% of all cases (n = 253), image fusion was technically successful. Image fusion was able to improve sensitivity and specificity of the single modality, or to add important diagnostic information. Image fusion was problematic in cases of different body positions between the two imaging modalities or different positions of mobile organs. In 37.9% of the cases, image fusion added clinically relevant information compared to the single modality. Conclusion: For clinical questions concerning liver, pancreas, rectum, neck, or neurocranium, image fusion is a reliable method suitable for routine clinical application. Organ motion still limits its feasibility and routine use in other areas (e.g., thorax). (orig.)

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  10. PET/MRI: a novel hybrid imaging technique. Major clinical indications and preliminary experience in Brazil.

    Science.gov (United States)

    Vitor, Taise; Martins, Karine Minaif; Ionescu, Tudor Mihai; Cunha, Marcelo Livorsi da; Baroni, Ronaldo Hueb; Garcia, Marcio Ricardo Taveira; Wagner, Jairo; Campos, Guilherme de Carvalho; Nogueira, Solange Amorim; Guerra, Elaine Gonçalves; Amaro, Edson

    2017-01-01

    In recent years, medical imaging with hybrid techniques has widely accepted and employed in clinical routine. PET/MRI offers significant advantages, including excellent contrast and resolution and reduced ionizing radiation, as compared to well-established PET/CT. Therefore, PET/MRI is a promising modality for oncologic imaging of some regions, such as brain, head and neck, liver and pelvis. This article set out to analyze clinical conditions that could benefit from PET/MRI imaging based on our caseload. The potential of PET/MRI to become the imaging modality of choice for assessment of neurologic and oncologic conditions associated with soft tissues is highlighted. Clinical aspects of PET/MRI and its application to clinical cases are illustrated with examples extracted from the authors' preliminary experience. RESUMO Nos últimos anos, imagens médicas com tecnologias híbridas tornaram-se amplamente aceitas e utilizadas na prática clínica. O PET/RM possui vantagens importantes, incluindo excelentes contrastes e resolução, e menor radiação ionizante, em comparação ao PET/TC. Por isto, é uma modalidade promissora para exames de imagem de pacientes oncológicos, para avaliar o cérebro, cabeça e pescoço, o fígado e a pelve. O objetivo deste artigo foi analisar as situações clínicas que se beneficiariam de exames de PET/RM a partir de uma casuística. Destacamos o potencial desta técnica se tornar o método de imagem de escolha para doenças neurológicas e oncológicas que envolvam partes moles. Os aspectos clínicos de PET/RM e sua aplicação aos casos clínicos são ilustrados com exemplos da experiência inicial dos autores.

  11. PET/MRI. Methodology and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Carrio, Ignasi [Autonomous Univ. of Barcelona, Hospital Sant Pau (Spain). Dept. Medicina Nuclear; Ros, Pablo (ed.) [Univ. Hospitals Case, Medical Center, Cleveland, OH (United States). Dept. of Radiology

    2014-04-01

    Provides detailed information on the methodology and equipment of MRI-PET. Covers a wide range of clinical applications in oncology, cardiology, and neurology. Written by an international group of experts in MRI and PET. PET/MRI is an exciting novel diagnostic imaging modality that combines the precise anatomic and physiologic information provided by magnetic resonance imaging (MRI) with the molecular data obtained with positron emission tomography (PET). PET/MRI offers the promise of a simplified work flow, reduced radiation, whole-body imaging with superior soft tissue contrast, and time of flight physiologic information. It has been described as the pathway to molecular imaging in medicine. In compiling this textbook, the editors have brought together a truly international group of experts in MRI and PET. The book is divided into two parts. The first part covers methodology and equipment and comprises chapters on basic molecular medicine, development of specific contrast agents, MR attenuation and validation, quantitative MRI and PET motion correction, and technical implications for both MRI and PET. The second part of the book focuses on clinical applications in oncology, cardiology, and neurology. Imaging of major neoplasms, including lymphomas and tumors of the breast, prostate, and head and neck, is covered in individual chapters. Further chapters address functional and metabolic cardiovascular examinations and major central nervous system applications such as brain tumors and dementias. Risks, safety aspects, and healthcare costs and impacts are also discussed. This book will be of interest to all radiologists and nuclear medicine physicians who wish to learn more about the latest developments in this important emerging imaging modality and its applications.

  12. Clinically relevant magnetic resonance imaging (MRI) findings in ...

    African Journals Online (AJOL)

    Background: Shoulder pain is the most common and well-documented site of musculoskeletal pain in elite swimmers. Structural abnormalities on magnetic resonance imaging (MRI) of elite swimmers' symptomatic shoulders are common. Little has been documented about the association between MRI findings in the ...

  13. Establishing a clinical cardiac MRI service

    International Nuclear Information System (INIS)

    O'Regan, D.P.; Schmitz, S.A.

    2006-01-01

    After several years of research development cardiovascular MRI has evolved into a widely accepted clinical tool. It offers important diagnostic and prognostic information for a variety of clinical indications, which include ischaemic heart disease, cardiomyopathies, valvular dysfunction and congenital heart disorders. It is a safe non-invasive technique that employs a variety of imaging sequences optimized for temporal or spatial resolution, tissue-specific contrast, flow quantification or angiography. Cardiac MRI offers specific advantages over conventional imaging techniques for a significant number of patients. The demand for cardiac MRI studies from cardiothoracic surgeons, cardiologists and other referrers is likely to continue to rise with pressure for more widespread local service provision. Setting up a cardiac MRI service requires careful consideration regarding funding issues and how it will be integrated with existing service provision. The purchase of cardiac phased array coils, monitoring equipment and software upgrades must also be considered, as well as the training needs of those involved. The choice of appropriate imaging protocols will be guided by operator experience, clinical indication and equipment capability, and is likely to evolve as the service develops. Post-processing and offline analysis form a significant part of the time taken to report studies and an efficient method of providing quantitative reports is an important requirement. Collaboration between radiologists and cardiologists is needed to develop a successful service and multi-disciplinary meetings are key component of this. This review will explore these issues from our perspective of a new clinical cardiac MRI service operating over its first year in a teaching hospital imaging department

  14. [MRI methods for pulmonary ventilation and perfusion imaging].

    Science.gov (United States)

    Sommer, G; Bauman, G

    2016-02-01

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O2-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies.

  15. MRI methods for pulmonary ventilation and perfusion imaging

    International Nuclear Information System (INIS)

    Sommer, G.; Bauman, G.

    2016-01-01

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O 2 -enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies. (orig.) [de

  16. Acceleration of cardiovascular MRI using parallel imaging: basic principles, practical considerations, clinical applications and future directions

    International Nuclear Information System (INIS)

    Niendorf, T.; Sodickson, D.

    2006-01-01

    Cardiovascular Magnetic Resonance (CVMR) imaging has proven to be of clinical value for non-invasive diagnostic imaging of cardiovascular diseases. CVMR requires rapid imaging; however, the speed of conventional MRI is fundamentally limited due to its sequential approach to image acquisition, in which data points are collected one after the other in the presence of sequentially-applied magnetic field gradients and radiofrequency coils to acquire multiple data points simultaneously, and thereby to increase imaging speed and efficiency beyond the limits of purely gradient-based approaches. The resulting improvements in imaging speed can be used in various ways, including shortening long examinations, improving spatial resolution and anatomic coverage, improving temporal resolution, enhancing image quality, overcoming physiological constraints, detecting and correcting for physiologic motion, and streamlining work flow. Examples of these strategies will be provided in this review, after some of the fundamentals of parallel imaging methods now in use for cardiovascular MRI are outlined. The emphasis will rest upon basic principles and clinical state-of-the art cardiovascular MRI applications. In addition, practical aspects such as signal-to-noise ratio considerations, tailored parallel imaging protocols and potential artifacts will be discussed, and current trends and future directions will be explored. (orig.)

  17. A study on the clinical significance of magnetic resonance imaging (MRI) findings in patients with cervical spondylotic myelopathy

    International Nuclear Information System (INIS)

    Toyooka, Satoshi

    1997-01-01

    This study was designed to evaluate magnetic resonance (MR) images of the cervical compressive myelopathy. It was also meant to serve as a review of clinical symptoms and an investigation of the usefulness of MRI. Comparative studies were carried out on 110 cases concerning the shape and signal intensity of the spinal cord, anterior epidural venous plexus MR images and clinical symptoms. The shape of the spinal cord and pre- and post-surgical conditions revealed by MRI correlated with clinical symptoms. As for the signal intensity of the spinal cord, in cases in which both high (T2-weighted image) and low (T1-weighted image) signals detected prior to surgery continued after surgery, as well as cases with high and low signals appearing after surgery, had the lower improvement than average. Low signal intensity on T1-weighted images are assumed to indicate irreversible changes of the spinal cord. High signal intensity on T2-weighted images is assumed to indicate both reversible and irreversible changes of the spinal cord. Epidural venous plexus can also be observed in healthy people and is not directly bound to clinical manifestations. Nevertheless, changes in the shape of the epidural venous plexus and signal intensity can reflect venous plexus compression and circulatory changes caused by compression. In the application of MRI to cervical compressive myelopathies, images of changes in the shape and signal intensity of the spinal cord and anterior epidural venous plexus images were considered important observations linked to clinical symptoms. MRI is an essential non-invasive imaging technique for the diagnosis of cervical compressive myelopathy, estimation of prognosis and postoperative follow-up. More investigations of compressive factors, circulatory dynamics of the spinal cord and high quality image are necessary. (author)

  18. fMRI. Basics and clinical applications. 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Ulmer, Stephan [Medizinisch Radiologisces Institut (MRI), Zuerich (Switzerland); Universitaetsklinikum Schleswig-Holstein, Kiel (Germany). Inst. fuer Neuroradiologie; Jansen, Olav (eds.) [Universitaetsklinikum Schleswig-Holstein, Kiel (Germany). Inst. fuer Neuroradiologie

    2013-11-01

    State of the art overview of fMRI. Covers technical issues, methods of statistical analysis, and the full range of clinical applications. Revised and expanded edition including discussion of novel aspects of analysis and further important applications. Includes comparisons with other brain mapping techniques and discussion of potential combined uses. Since functional MRI (fMRI) and the basic method of BOLD imaging were introduced in 1993 by Seiji Ogawa, fMRI has evolved into an invaluable clinical tool for routine brain imaging, and there have been substantial improvements in both the imaging technique itself and the associated statistical analysis. This book provides a state of the art overview of fMRI and its use in clinical practice. Experts in the field share their knowledge and explain how to overcome diverse potential technical barriers and problems. Starting from the very basics on the origin of the BOLD signal, the book covers technical issues, anatomical landmarks, the full range of clinical applications, methods of statistical analysis, and special issues in various clinical fields. Comparisons are made with other brain mapping techniques, such as DTI, PET, TMS, EEG, and MEG, and their combined use with fMRI is also discussed. Since the first edition, original chapters have been updated and new chapters added, covering both novel aspects of analysis and further important clinical applications.

  19. Heterogeneous Optimization Framework: Reproducible Preprocessing of Multi-Spectral Clinical MRI for Neuro-Oncology Imaging Research

    OpenAIRE

    Milchenko, Mikhail; Snyder, Abraham Z.; LaMontagne, Pamela; Shimony, Joshua S; Benzinger, Tammie L.; Fouke, Sarah Jost; Marcus, Daniel S.

    2016-01-01

    Neuroimaging research often relies on clinically acquired magnetic resonance imaging (MRI) datasets that can originate from multiple institutions. Such datasets are characterized by high heterogeneity of modalities and variability of sequence parameters. This heterogeneity complicates the automation of image processing tasks such as spatial co-registration and physiological or functional image analysis.

  20. MRI Reporter Genes for Noninvasive Molecular Imaging

    Directory of Open Access Journals (Sweden)

    Caixia Yang

    2016-05-01

    Full Text Available Magnetic resonance imaging (MRI is one of the most important imaging technologies used in clinical diagnosis. Reporter genes for MRI can be applied to accurately track the delivery of cell in cell therapy, evaluate the therapy effect of gene delivery, and monitor tissue/cell-specific microenvironments. Commonly used reporter genes for MRI usually include genes encoding the enzyme (e.g., tyrosinase and β-galactosidase, the receptor on the cells (e.g., transferrin receptor, and endogenous reporter genes (e.g., ferritin reporter gene. However, low sensitivity limits the application of MRI and reporter gene-based multimodal imaging strategies are common including optical imaging and radionuclide imaging. These can significantly improve diagnostic efficiency and accelerate the development of new therapies.

  1. [Fusion of MRI, fMRI and intraoperative MRI data. Methods and clinical significance exemplified by neurosurgical interventions].

    Science.gov (United States)

    Moche, M; Busse, H; Dannenberg, C; Schulz, T; Schmitgen, A; Trantakis, C; Winkler, D; Schmidt, F; Kahn, T

    2001-11-01

    The aim of this work was to realize and clinically evaluate an image fusion platform for the integration of preoperative MRI and fMRI data into the intraoperative images of an interventional MRI system with a focus on neurosurgical procedures. A vertically open 0.5 T MRI scanner was equipped with a dedicated navigation system enabling the registration of additional imaging modalities (MRI, fMRI, CT) with the intraoperatively acquired data sets. These merged image data served as the basis for interventional planning and multimodal navigation. So far, the system has been used in 70 neurosurgical interventions (13 of which involved image data fusion--requiring 15 minutes extra time). The augmented navigation system is characterized by a higher frame rate and a higher image quality as compared to the system-integrated navigation based on continuously acquired (near) real time images. Patient movement and tissue shifts can be immediately detected by monitoring the morphological differences between both navigation scenes. The multimodal image fusion allowed a refined navigation planning especially for the resection of deeply seated brain lesions or pathologies close to eloquent areas. Augmented intraoperative orientation and instrument guidance improve the safety and accuracy of neurosurgical interventions.

  2. Self-resolving focal non-ossifying myositis: a poorly known clinical and imaging entity diagnosed with MRI

    International Nuclear Information System (INIS)

    Perlepe, Vasiliki; Dallaudière, Benjamin; Omoumi, Patrick; Hristova, Lora; Rezzazadeh, Afshin; Vande Berg, Bruno; Malghem, Jacques; Lecouvet, Frederic

    2015-01-01

    Focal myositis is a rare benign inflammatory pseudotumor, presenting as a painful nodular mass within a muscle, and characterized by spontaneous resolution within weeks. To assess the clinical and imaging findings of focal nodular myositis simulating a neoplasm at clinical examination, with no history of trauma. This study describes the locations and appearance at ultrasonography (US), computed tomography (CT), and magnetic resonance imaging (MRI) of this condition in a series of five patients. MRI and US displayed a solid intramuscular “tumor” and suggested a continuum between the proximal and distal muscle fibers that appeared thickened within the nodular lesion, a sign that has been reported in myositis ossificans. MRI showed edema in adjacent muscles and soft tissues, as well as intense enhancement of the mass. Intense vascular flows were seen at Doppler analysis. CT did not reveal the appearance of peripheral ossifications, ruling out the diagnosis of myositis ossificans. In some patients, the diagnosis of sarcoma had been suggested as possible by the radiologist. Imaging follow-up with MRI showed complete resolution of the masses over several weeks, thus avoiding a biopsy; no recurrence was observed at long-term follow-up (more than 24 months). This paper highlights MRI and US findings in focal non-ossifying myositis, and emphasizes the role of MRI in suggesting this diagnosis, leading to the careful follow-up of the lesion until its resolution, and ruling out more aggressive lesions

  3. Unexpected MRI findings in clinically suspected Legg-Calve-Perthes disease

    Energy Technology Data Exchange (ETDEWEB)

    Lobert, Philip F.; Dillman, Jonathan R.; Strouse, Peter J.; Hernandez, Ramiro J. [University of Michigan Health System, Department of Radiology, Section of Pediatric Radiology, C.S. Mott Children' s Hospital/F3503, Ann Arbor, MI (United States)

    2011-03-15

    In the setting of clinically suspected Legg-Calve-Perthes (LCP) disease and negative/equivocal radiographs, contrast-enhanced MRI can be performed to confirm the diagnosis. To determine the frequency of unexpected causes of hip pain as identified by MRI in children with clinically suspected LCP disease and negative/equivocal radiographs. All pediatric contrast-enhanced MRI examinations of the pelvis and hips performed between January 2000 and February 2009 to evaluate for possible LCP disease in the setting of negative/equivocal radiographs were identified. MRI examinations performed to evaluate for secondary avascular necrosis were excluded. Imaging reports were retrospectively reviewed for unexpected clinically important causes of hip pain. Thirty-six pediatric patients underwent contrast-enhanced MRI examinations for clinically suspected LCP disease in the setting of negative/equivocal radiographs. Twenty-two (61%) imaging studies were normal, while four (11%) imaging studies demonstrated findings consistent with LCP disease. Ten (28%) imaging studies revealed unexpected clinically important causes of hip pain, including nonspecific unilateral joint effusion and synovitis (n = 7, juvenile chronic arthritis was eventually diagnosed in 3 patients), sacral fracture (n = 1), apophyseal injury (n = 1), and femoral head subluxation (n = 1). MRI frequently reveals unexpected clinically important causes of hip pain in children with suspected LCP disease and negative/equivocal radiographs. (orig.)

  4. Clinical significance of MRI/18F-FDG PET fusion imaging of the spinal cord in patients with cervical compressive myelopathy

    International Nuclear Information System (INIS)

    Uchida, Kenzo; Nakajima, Hideaki; Watanabe, Shuji; Yoshida, Ai; Baba, Hisatoshi; Okazawa, Hidehiko; Kimura, Hirohiko; Kudo, Takashi

    2012-01-01

    18 F-FDG PET is used to investigate the metabolic activity of neural tissue. MRI is used to visualize morphological changes, but the relationship between intramedullary signal changes and clinical outcome remains controversial. The present study was designed to evaluate the use of 3-D MRI/ 18 F-FDG PET fusion imaging for defining intramedullary signal changes on MRI scans and local glucose metabolic rate measured on 18 F-FDG PET scans in relation to clinical outcome and prognosis. We studied 24 patients undergoing decompressive surgery for cervical compressive myelopathy. All patients underwent 3-D MRI and 18 F-FDG PET before surgery. Quantitative analysis of intramedullary signal changes on MRI scans included calculation of the signal intensity ratio (SIR) as the ratio between the increased lesional signal intensity and the signal intensity at the level of the C7/T1 disc. Using an Advantage workstation, the same slices of cervical 3-D MRI and 18 F-FDG PET images were fused. On the fused images, the maximal count of the lesion was adopted as the standardized uptake value (SUV max ). In a similar manner to SIR, the SUV ratio (SUVR) was also calculated. Neurological assessment was conducted using the Japanese Orthopedic Association (JOA) scoring system for cervical myelopathy. The SIR on T1-weighted (T1-W) images, but not SIR on T2-W images, was significantly correlated with preoperative JOA score and postoperative neurological improvement. Lesion SUV max was significantly correlated with SIR on T1-W images, but not with SIR on T2-W images, and also with postoperative neurological outcome. The SUVR correlated better than SIR on T1-W images and lesion SUV max with neurological improvement. Longer symptom duration was correlated negatively with SIR on T1-W images, positively with SIR on T2-W images, and negatively with SUV max . Our results suggest that low-intensity signal on T1-W images, but not on T2-W images, is correlated with a poor postoperative neurological

  5. PET-MRI: the likely future of molecular imaging

    International Nuclear Information System (INIS)

    Chen Xiang; Zhao Jinhua; Zhao Jun

    2008-01-01

    PET-CT is a successful combination of functional and morphologic information, and it has already been shown to have great value both in clinics and in scientific research. MRI is another kind of morphologic imaging method, in contrast to CT, MRI can yield images with higher soft-tissue contrast and better spatial resolution. The combination of PET and MRI for simultaneous data acquisition should have far- reaching consequences for molecular imaging. This review will talk about the problems met in the development of PET-MRI and describe the progress to date and look forward to its potential application. (authors)

  6. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Magnetic Resonance Imaging (MRI) is a medical imaging procedure for ...

  7. Cardiac Imaging Using Clinical 1.5 T MRI Scanners in a Murine Ischemia/Reperfusion Model

    Directory of Open Access Journals (Sweden)

    Jakob G. J. Voelkl

    2011-01-01

    Full Text Available To perform cardiac imaging in mice without having to invest in expensive dedicated equipment, we adapted a clinical 1.5 Tesla (T magnetic resonance imaging (MRI scanner for use in a murine ischemia/reperfusion model. Phase-sensitive inversion recovery (PSIR sequence facilitated the determination of infarct sizes in vivo by late gadolinium enhancement. Results were compared to histological infarct areas in mice after ischemia/reperfusion procedure with a good correlation (=0.807, <.001. In addition, fractional area change (FAC was assessed with single slice cine MRI and was matched to infarct size (=−0.837 and fractional shortening (FS measured with echocardiography (=0.860; both <.001. Here, we demonstrate the use of clinical 1.5 MRI scanners as a feasible method for basic phenotyping in mice. These widely available scanners are capable of investigating in vivo infarct dimensions as well as assessment of cardiac functional parameters in mice with reasonable throughput.

  8. Optimal use of MRI in clinical trials, clinical care and clinical registries of patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Møller-Bisgaard, Signe

    2014-01-01

    the benefits of including MRI in treat-to-target strategies. The benefits of incorporating MRI into clinical registries are not yet known, but may include improved knowledge about the real-life advantages of MRI, as well as opportunities to develop better clinical and laboratory composite measures to monitor......Magnetic resonance imaging (MRI) clearly is more sensitive than clinical examination and conventional radiography (x-ray) for detection of inflammation (synovitis, bone marrow oedema (osteitis) and tenosynovitis) and damage (bone erosion and cartilage loss/joint space narrowing) in patients...... with rheumatoid arthritis (RA). The question is when and how MRI should be used. The present article reviews our knowledge about, and provides suggestions for, the use of MRI in clinical trials, clinical care and clinical registries. In clinical trials, the OMERACT RA MRI scoring system (RAMRIS) is a thoroughly...

  9. MRI of the hip at 7T: feasibility of bone microarchitecture, high-resolution cartilage, and clinical imaging.

    Science.gov (United States)

    Chang, Gregory; Deniz, Cem M; Honig, Stephen; Egol, Kenneth; Regatte, Ravinder R; Zhu, Yudong; Sodickson, Daniel K; Brown, Ryan

    2014-06-01

    To demonstrate the feasibility of performing bone microarchitecture, high-resolution cartilage, and clinical imaging of the hip at 7T. This study had Institutional Review Board approval. Using an 8-channel coil constructed in-house, we imaged the hips of 15 subjects on a 7T magnetic resonance imaging (MRI) scanner. We applied: 1) a T1-weighted 3D fast low angle shot (3D FLASH) sequence (0.23 × 0.23 × 1-1.5 mm(3) ) for bone microarchitecture imaging; 2) T1-weighted 3D FLASH (water excitation) and volumetric interpolated breath-hold examination (VIBE) sequences (0.23 × 0.23 × 1.5 mm(3) ) with saturation or inversion recovery-based fat suppression for cartilage imaging; 3) 2D intermediate-weighted fast spin-echo (FSE) sequences without and with fat saturation (0.27 × 0.27 × 2 mm) for clinical imaging. Bone microarchitecture images allowed visualization of individual trabeculae within the proximal femur. Cartilage was well visualized and fat was well suppressed on FLASH and VIBE sequences. FSE sequences allowed visualization of cartilage, the labrum (including cartilage and labral pathology), joint capsule, and tendons. This is the first study to demonstrate the feasibility of performing a clinically comprehensive hip MRI protocol at 7T, including high-resolution imaging of bone microarchitecture and cartilage, as well as clinical imaging. Copyright © 2013 Wiley Periodicals, Inc.

  10. Clinical and MRI evaluation of tuberculous meningitis

    International Nuclear Information System (INIS)

    Jiang Chunjing; Shu Jiner; Chen Jian; Sheng Sanlan; Lu Jinhua; Cai Xiaoxiao; Li Huimin

    2010-01-01

    Objective: To evaluate the relationship of clinical and magnetic resonance imaging (MRI) findings in patients with tuberculous meningitis (TBM), and to improve the understanding of TBM. Methods: The clinical and MRI findings in 42 patients with confirmed TBM were analyzed retrospectively. MRI examination was performed using a 1 Tesla system, including SE T 1 WI and T 2 WI. Intravenous contrast was injected in 29 patients, and follow-up scans were performed on 17 patients. Results: Of 24 patients with early TBM, MRI was abnormal in 5(21%) with slight Tl-hypointense meningeal (4) or ependymal thickening (1). MRI on 33/35 (94%) patients with late stage TBM was abnormal with T 1 hypointensity and T 2 hyperintensity including meningeal thickening (19), mild surrounding brain edema (10), nodules (11), tuberculoma (5) and abscess (2). There was significant plaque-like, nodular or rim enhancement with surrounding brain edema. Conclusion: Tuberculous meningitis has minimal clinical and MRI findings in the early phase and significant clinical and MRI findings in the late phase. The enhanced scan may help to detect the abnormality. (authors)

  11. Physiological and technical limitations of functional magnetic resonance imaging (fMRI) - consequences for clinical use

    International Nuclear Information System (INIS)

    Wuestenberg, T.; Jordan, K.; Giesel, F.L.; Villringer, A.

    2003-01-01

    Functional magnetic resonance imaging (fMRI) is the most common noninvasive technique in functional neuroanatomy. The capabilities and limitations of the method will be discussed based on a short review of the current knowledge about the neurovascular relationship. The focus of this article is on current methodical and technical problems regarding fMRI-based detection and localization of neuronal activity. Main error sources and their influence on the reliability and validity of fMRI-methods are presented. Appropriate solution strategies will be proposed and evaluated. Finally, the clinical relevance of MR-based diagnostic methods are discussed. (orig.) [de

  12. MRI assessment program. Consensus statement on clinical efficacy of MRI

    International Nuclear Information System (INIS)

    1998-05-01

    This consensus statement is largely based on the experience gained at the MRI units at the four hospitals which have operated scanners in the MRI program. It reflects the considered opinion of the radiologists responsible for the MRI services at those hospitals. Account has also been taken of relevant overseas data. This collection of opinion relates particularly to comparison with other imaging modalities. The specific comments will require further consideration as technical developments with MRI become available, additional experience is gained with gadolinium contrast material and additional data are obtained on the influence of MRI on patient management. MRI, at present, is used either to improve diagnostic accuracy when other tests are negative or equivocal, when there is strong clinical suspicion of disease, or to improve surgical or other management planning when the diagnosis known. In some situations (eg syringomyelia, congenital spinal disease, posterior fossa/cerebello-pontine angle tumours) it may entirely replace other tests (eg myelography, air contrast, CT) which are substantially less accurate and/or more invasive. In other situations (eg hemispheric brain tumours, lumbar disc protrusions) when other tests, such as CT, can be as accurate, MRI is not usually or initially indicated because it is currently more expensive and of limited availability. However, balanced against this is the fact that it does not expose the patient to potentially harmful ionising radiation. It is also stressed that MRI images depend on complex, widely variable and, as yet, incompletely understood parameters. There is concern that this may result in false positive diagnoses, especially where MRI is used alone as a screening test, or used as the initial test. For several reasons (availability, cost, medical and diagnostic efficacy), the specific comments on indications for MRI presented are based upon the assumption that MRI is a tertiary and complementary imaging examination

  13. Clinical significance of MRI/{sup 18}F-FDG PET fusion imaging of the spinal cord in patients with cervical compressive myelopathy

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Kenzo; Nakajima, Hideaki; Watanabe, Shuji; Yoshida, Ai; Baba, Hisatoshi [University of Fukui, Department of Orthopaedics and Rehabilitation Medicine, Faculty of Medical Sciences, Eiheiji, Fukui (Japan); Okazawa, Hidehiko [University of Fukui, Department of Biomedical Imaging Research Center, Eiheiji, Fukui (Japan); Kimura, Hirohiko [University of Fukui, Departments of Radiology, Faculty of Medical Sciences, Eiheiji, Fukui (Japan); Kudo, Takashi [Nagasaki University, Department of Radioisotope Medicine, Atomic Bomb Disease and Hibakusha Medicine Unit, Atomic Bomb Disease Institute, Nagasaki (Japan)

    2012-10-15

    {sup 18}F-FDG PET is used to investigate the metabolic activity of neural tissue. MRI is used to visualize morphological changes, but the relationship between intramedullary signal changes and clinical outcome remains controversial. The present study was designed to evaluate the use of 3-D MRI/{sup 18}F-FDG PET fusion imaging for defining intramedullary signal changes on MRI scans and local glucose metabolic rate measured on {sup 18}F-FDG PET scans in relation to clinical outcome and prognosis. We studied 24 patients undergoing decompressive surgery for cervical compressive myelopathy. All patients underwent 3-D MRI and {sup 18}F-FDG PET before surgery. Quantitative analysis of intramedullary signal changes on MRI scans included calculation of the signal intensity ratio (SIR) as the ratio between the increased lesional signal intensity and the signal intensity at the level of the C7/T1 disc. Using an Advantage workstation, the same slices of cervical 3-D MRI and {sup 18}F-FDG PET images were fused. On the fused images, the maximal count of the lesion was adopted as the standardized uptake value (SUV{sub max}). In a similar manner to SIR, the SUV ratio (SUVR) was also calculated. Neurological assessment was conducted using the Japanese Orthopedic Association (JOA) scoring system for cervical myelopathy. The SIR on T1-weighted (T1-W) images, but not SIR on T2-W images, was significantly correlated with preoperative JOA score and postoperative neurological improvement. Lesion SUV{sub max} was significantly correlated with SIR on T1-W images, but not with SIR on T2-W images, and also with postoperative neurological outcome. The SUVR correlated better than SIR on T1-W images and lesion SUV{sub max} with neurological improvement. Longer symptom duration was correlated negatively with SIR on T1-W images, positively with SIR on T2-W images, and negatively with SUV{sub max}. Our results suggest that low-intensity signal on T1-W images, but not on T2-W images, is correlated

  14. Clinical applications of 7 T MRI in the brain

    International Nuclear Information System (INIS)

    Kolk, Anja G. van der; Hendrikse, Jeroen; Zwanenburg, Jaco J.M.; Visser, Fredy; Luijten, Peter R.

    2013-01-01

    This review illustrates current applications and possible future directions of 7 Tesla (7 T) Magnetic Resonance Imaging (MRI) in the field of brain MRI, in clinical studies as well as clinical practice. With its higher signal-to-noise (SNR) and contrast-to-noise ratio (CNR) compared to lower field strengths, high resolution, contrast-rich images can be obtained of diverse pathologies, like multiple sclerosis (MS), brain tumours, aging-related changes and cerebrovascular diseases. In some of these diseases, additional pathophysiological information can be gained compared to lower field strengths. Because of clear depiction of small anatomical details, and higher lesion conspicuousness, earlier diagnosis and start of treatment of brain diseases may become possible. Furthermore, additional insight into the pathogenesis of brain diseases obtained with 7 T MRI could be the basis for new treatment developments. However, imaging at high field comes with several limitations, like inhomogeneous transmit fields, a higher specific absorption rate (SAR) and, currently, extensive contraindications for patient scanning. Future studies will be aimed at assessing the advantages and disadvantages of 7 T MRI over lower field strengths in light of clinical applications, specifically the additional diagnostic and prognostic value of 7 T MRI

  15. Clinical applications of 7 T MRI in the brain

    Energy Technology Data Exchange (ETDEWEB)

    Kolk, Anja G. van der, E-mail: A.G.vanderKolk@umcutrecht.nl [Department of Radiology, University Medical Center Utrecht, Postbox 85500, 3508 GA Utrecht (Netherlands); Hendrikse, Jeroen, E-mail: J.Hendrikse@umcutrecht.nl [Department of Radiology, University Medical Center Utrecht, Postbox 85500, 3508 GA Utrecht (Netherlands); Zwanenburg, Jaco J.M., E-mail: J.J.M.Zwanenburg@umcutrecht.nl [Department of Radiology, University Medical Center Utrecht, Postbox 85500, 3508 GA Utrecht (Netherlands); Image Sciences Institute, University Medical Center Utrecht (Netherlands); Visser, Fredy, E-mail: F.Visser-2@umcutrecht.nl [Department of Radiology, University Medical Center Utrecht, Postbox 85500, 3508 GA Utrecht (Netherlands); Philips Healthcare, Best (Netherlands); Luijten, Peter R., E-mail: P.Luijten@umcutrecht.nl [Department of Radiology, University Medical Center Utrecht, Postbox 85500, 3508 GA Utrecht (Netherlands)

    2013-05-15

    This review illustrates current applications and possible future directions of 7 Tesla (7 T) Magnetic Resonance Imaging (MRI) in the field of brain MRI, in clinical studies as well as clinical practice. With its higher signal-to-noise (SNR) and contrast-to-noise ratio (CNR) compared to lower field strengths, high resolution, contrast-rich images can be obtained of diverse pathologies, like multiple sclerosis (MS), brain tumours, aging-related changes and cerebrovascular diseases. In some of these diseases, additional pathophysiological information can be gained compared to lower field strengths. Because of clear depiction of small anatomical details, and higher lesion conspicuousness, earlier diagnosis and start of treatment of brain diseases may become possible. Furthermore, additional insight into the pathogenesis of brain diseases obtained with 7 T MRI could be the basis for new treatment developments. However, imaging at high field comes with several limitations, like inhomogeneous transmit fields, a higher specific absorption rate (SAR) and, currently, extensive contraindications for patient scanning. Future studies will be aimed at assessing the advantages and disadvantages of 7 T MRI over lower field strengths in light of clinical applications, specifically the additional diagnostic and prognostic value of 7 T MRI.

  16. Clinically relevant magnetic resonance imaging (MRI findings in elite swimmers’ shoulders

    Directory of Open Access Journals (Sweden)

    Arno Celliers

    2017-01-01

    Objective: To assess clinically relevant MRI findings in the shoulders of symptomatic and asymptomatic elite swimmers. Method: Twenty (aged 16–23 years elite swimmers completed questionnaires on their swimming training, pain and shoulder function. MRI of both shoulders (n = 40 were performed and all swimmers were given a standardised clinical shoulder examination. Results: Both shoulders of 11 male and 9 female elite swimmers (n = 40 were examined. Eleven of the 40 shoulders were clinically symptomatic and 29 were asymptomatic. The most common clinical finding in both the symptomatic and asymptomatic shoulders was impingement during internal rotation, with impingement in 54.5% of the symptomatic shoulders and in 31.0% of the asymptomatic shoulders. The most common MRI findings in the symptomatic and asymptomatic shoulders were supraspinatus tendinosis (45.5% vs. 20.7%, subacromial subdeltoid fluid (45.5% vs. 34.5%, increased signal in the AC Joint (45.5% vs. 37.9% and AC joint arthrosis (36.4% vs. 34.5%. Thirty-nine (97.5% of the shoulders showed abnormal MRI features. Conclusion: MRI findings in the symptomatic and asymptomatic shoulders of young elite swimmers are similar and care should be taken when reporting shoulder MRIs in these athletes. Asymptomatic shoulders demonstrate manifold MRI abnormalities that may be radiologically significant but appear not to be clinically significant.

  17. Advance MRI for pediatric brain tumors with emphasis on clinical benefits

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo; Ra, Young Shin [Asan Medical Center, University of Ulsan College of Medicine, Seoul(Korea, Republic of)

    2017-01-15

    Conventional anatomic brain MRI is often limited in evaluating pediatric brain tumors, the most common solid tumors and a leading cause of death in children. Advanced brain MRI techniques have great potential to improve diagnostic performance in children with brain tumors and overcome diagnostic pitfalls resulting from diverse tumor pathologies as well as nonspecific or overlapped imaging findings. Advanced MRI techniques used for evaluating pediatric brain tumors include diffusion-weighted imaging, diffusion tensor imaging, functional MRI, perfusion imaging, spectroscopy, susceptibility-weighted imaging, and chemical exchange saturation transfer imaging. Because pediatric brain tumors differ from adult counterparts in various aspects, MRI protocols should be designed to achieve maximal clinical benefits in pediatric brain tumors. In this study, we review advanced MRI techniques and interpretation algorithms for pediatric brain tumors.

  18. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  20. MRI of Creutzfeldt-Jakob disease: Imaging features and recommended MRI protocol

    Energy Technology Data Exchange (ETDEWEB)

    Collie, D.A.; Sellar, R.J.; Zeidler, M.; Colchester, A.C.F.; Knight, R.; Will, R.G

    2001-09-01

    Creutzfeldt-Jakob Disease (CJD) is a rare, progressive and invariably fatal neurodegenerative disease characterized by specific histopathological features. Of the four subtypes of CJD described, the commonest is sporadic CJD (sCJD). More recently, a new clinically distinct form of the disease affecting younger patients, known as variant CJD (vCJD), has been identified, and this has been causally linked to the bovine spongiform encephalopathy (BSE) agent in cattle. Characteristic appearances on magnetic resonance imaging (MRI) have been identified in several forms of CJD; sCJD may be associated with high signal changes in the putamen and caudate head and vCJD is usually associated with hyperintensity of the pulvinar (posterior nuclei) of the thalamus. These appearances and other imaging features are described in this article. Using appropriate clinical and radiological criteria and tailored imaging protocols, MRI plays an important part in the in vivodiagnosis of this disease. Collie, D.A. et al. (2001)

  1. MRI of Creutzfeldt-Jakob disease: Imaging features and recommended MRI protocol

    International Nuclear Information System (INIS)

    Collie, D.A.; Sellar, R.J.; Zeidler, M.; Colchester, A.C.F.; Knight, R.; Will, R.G.

    2001-01-01

    Creutzfeldt-Jakob Disease (CJD) is a rare, progressive and invariably fatal neurodegenerative disease characterized by specific histopathological features. Of the four subtypes of CJD described, the commonest is sporadic CJD (sCJD). More recently, a new clinically distinct form of the disease affecting younger patients, known as variant CJD (vCJD), has been identified, and this has been causally linked to the bovine spongiform encephalopathy (BSE) agent in cattle. Characteristic appearances on magnetic resonance imaging (MRI) have been identified in several forms of CJD; sCJD may be associated with high signal changes in the putamen and caudate head and vCJD is usually associated with hyperintensity of the pulvinar (posterior nuclei) of the thalamus. These appearances and other imaging features are described in this article. Using appropriate clinical and radiological criteria and tailored imaging protocols, MRI plays an important part in the in vivodiagnosis of this disease. Collie, D.A. et al. (2001)

  2. Optimized workflow and imaging protocols for whole-body oncologic PET/MRI.

    Science.gov (United States)

    Ishii, Shirou; Hara, Takamitsu; Nanbu, Takeyuki; Suenaga, Hiroki; Sugawara, Shigeyasu; Kuroiwa, Daichi; Sekino, Hirofumi; Miyajima, Masayuki; Kubo, Hitoshi; Oriuchi, Noboru; Ito, Hiroshi

    2016-11-01

    Although PET/MRI has the advantages of a simultaneous acquisition of PET and MRI, high soft-tissue contrast of the MRI images, and reduction of radiation exposure, its low profitability and long acquisition time are significant problems in clinical settings. Thus, MRI protocols that meet oncological purposes need to be used in order to reduce examination time while securing detectability. Currently, half-Fourier acquisition single-shot turbo spin echo and 3D-T1 volumetric interpolated breath-hold examination may be the most commonly used sequences for whole-body imaging due to their shorter acquisition time and higher diagnostic accuracy. Although there have been several reports that adding diffusion weighted image (DWI) to PET/MRI protocol has had no effect on tumor detection to date, in cases of liver, kidney, bladder, and prostate cancer, the use of DWI may be beneficial in detecting lesions. Another possible option is to scan each region with different MRI sequences instead of scanning the whole body using one sequence continuously. We herein report a workflow and imaging protocols for whole-body oncologic PET/MRI using an integrated system in the clinical routine, designed for the detection, for example by cancer screening, of metastatic lesions, in order to help future users optimize their workflow and imaging protocols.

  3. The Usefulness of Readout-Segmented Echo-Planar Imaging (RESOLVE) for Bio-phantom Imaging Using 3-Tesla Clinical MRI.

    Science.gov (United States)

    Yoshimura, Yuuki; Kuroda, Masahiro; Sugiantoc, Irfan; Bamgbosec, Babatunde O; Miyahara, Kanae; Ohmura, Yuichi; Kurozumi, Akira; Matsushita, Toshi; Ohno, Seiichiro; Kanazawa, Susumu; Asaumi, Junichi

    2018-02-01

    Readout-segmented echo-planar imaging (RESOLVE) is a multi-shot echo-planar imaging (EPI) modality with k-space segmented in the readout direction. We investigated whether RESOLVE decreases the distortion and artifact in the phase direction and increases the signal-to-noise ratio (SNR) in phantoms image taken with 3-tesla (3T) MRI versus conventional EPI. We used a physiological saline phantom and subtraction mapping and observed that RESOLVE's SNR was higher than EPI's. Using RESOLVE, the combination of a special-purpose coil and a large-loop coil had a higher SNR compared to using only a head/neck coil. RESOLVE's image distortioas less than EPI's. We used a 120 mM polyethylene glycol phantom to examine the phase direction artifact.vThe range where the artifact appeared in the apparent diffusion coefficient (ADC) image was shorter with RESOLVE compared to EPI. We used RESOLVE to take images of a Jurkat cell bio-phantom: the cell-region ADC was 856×10-6mm2/sec and the surrounding physiological saline-region ADC was 2,951×10-6mm2/sec. The combination of RESOLVE and the 3T clinical MRI device reduced image distortion and improved SNR and the identification of accurate ADC values due to the phase direction artifact reduction. This combination is useful for obtaining accurate ADC values of bio-phantoms.

  4. PET/MRI: a novel hybrid imaging technique: major clinical indications and preliminary experience in Brazil; PET/RM: um novo metodo de imagem hibrida: principais indicacoes clinicas e experiencia preliminar no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Vitor, Taise; Martins, Karine Minaif; Ionescu, Tudor Mihai and others, E-mail: taisevitor@gmail.com [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil)

    2017-04-01

    In recent years, medical imaging with hybrid techniques has widely accepted and employed in clinical routine. PET/MRI offers significant advantages, including excellent contrast and resolution and reduced ionizing radiation, as compared to well-established PET/ CT. Therefore, PET/MRI is a promising modality for oncologic imaging of some regions, such as brain, head and neck, liver and pelvis. This article set out to analyze clinical conditions that could benefit from PET/MRI imaging based on our caseload. The potential of PET/MRI to become the imaging modality of choice for assessment of neurologic and oncologic conditions associated with soft tissues is highlighted. Clinical aspects of PET/MRI and its application to clinical cases are illustrated with examples extracted from the authors' preliminary experience. (author)

  5. Development and application of PET-MRI image fusion technology

    International Nuclear Information System (INIS)

    Song Jianhua; Zhao Jinhua; Qiao Wenli

    2011-01-01

    The emerging and growing in popularity of PET-CT scanner brings us the convenience and cognizes the advantages such as diagnosis, staging, curative effect evaluation and prognosis for malignant tumor. And the PET-MRI installing maybe a new upsurge when the machine gradually mature, because of the MRI examination without the radiation exposure and with the higher soft tissue resolution. This paper summarized the developing course of image fusion technology and some researches of clinical application about PET-MRI at present, in order to help people to understand the functions and know its wide application of the upcoming new instrument, mainly focuses the application on the central nervous system and some soft tissue lesions. And before PET-MRI popularization, people can still carry out some researches of various image fusion and clinical application on the current equipment. (authors)

  6. Clinical assessment of CT-MRI image fusion software in localization of the prostate for 3D conformal radiation therapy

    International Nuclear Information System (INIS)

    Kagawa, Kazufumi; Lee, W. Robert; Schultheiss, Timothy E.; Hunt, Margie A.; Shaer, Andrew H.; Hanks, Gerald E.

    1996-01-01

    Purpose: To assess the utility of image fusion software and compare MRI prostate localization with CT localization in patients undergoing 3D conformal radiation therapy of prostate cancer. Materials and Methods: After a phantom study was performed to ensure the accuracy of image fusion procedure, 22 prostate cancer patients had CT and MRI studies before the start of radiotherapy. Immobilization casts used during radiation treatment were also used for both imaging studies. After the clinical target volume (CTV) (prostate or prostate + seminal vesicles) was defined on CT, slices from MRI study were reconstructed to match precisely the corresponding CT slices by identifying three common bony landmarks on each study. The CTV was separately defined on the matched MRI slices. Data related to the size and location of the prostate were compared between CT and MRI. The spatial relationship between the tip of urethrogram cone on CT and prostate apex seen on MRI was also scrutinized. Results: The phantom study showed the registration discrepancies between CT and MRI smaller than 1.0 mm in any pair of comparison. The patient study showed mean image registration error of 0.9 (± 0.6) mm. The average prostate volume was 63.0 (± 25.8) cm 3 and 50.9 (± 22.9) cm 3 determined by CT and MRI respectively (Fig. 1). The difference in prostate location with the two studies most commonly differed at the base and at the apex of the prostate (Fig. 2). On transverse MRI, the prostate apex was situated 7.1 (± 4.5) mm dorsal and 15.1 (± 4.0) mm cephalad to the tip of urethrogram cone (Fig. 3). Conclusions: CT-MRI image fusion study made it possible to compare the two modalities directly. MRI localization of the prostate is more accurate than CT, and indicates the distance from cone to apex is 15 mm. In view of excellent treatment results obtained with current CT localization of the prostate, still it may not be wise to reduce target volume to that demonstrated on MRI

  7. Magnetic Resonance Imaging (MRI) Safety

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how ... What is MRI and how does it work? Magnetic resonance imaging, or MRI, is a way of obtaining ...

  8. Magnetic resonance imaging (MRI) of an intraventricular hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Ryungchan; Higashi, Tooru; Ito, Shotaro; Kadoya, Satoru; Takarada, Akira; Sato, Shuji; Kurauchi, Manabu.

    1987-08-01

    The utility of MRI was investigated in 10 patients with intraventricular hemorrhage. MRI was found to be, in many respects, superior to CT: 1) MRI is able to detect to some extent the aging of an intraventricular hematoma. 2) It can determine the character of intraventricular cerebrospinal fluid, whether it is normal, bloody, or hyperprotein. 3) It can detect the cause of hemorrhage in the case of arterio-venous malformation. 4) MRI permits the detection of the penetration course and the location of a ventricular hematoma. 5) It can clearly detect periventricular lesions of early-stage hydrocephalus, accompanied by increased intracranial pressure and followed by intraventricular hemorrhage, by imaging the periventricular high-signal-intensity area. 6) MRI can clearly diagnose complications of intracranial lesions. For instance, it can distinguish subdural fluid collection from chronic subdural hematoma and can detect whether a cerebral infarction is new or old. On the other hand, MRI also has some disadvantages: 1) The imaging time is long, and clinical application is difficult, in serious and/or infant cases. 2) It is impossible to use MRI in some patients who have magnetic material in their bodies. 3) The spatial-image resolution is not good.

  9. Soft tissue manifestations of early rheumatic disease. Imaging with MRI

    International Nuclear Information System (INIS)

    Treitl, M.; Panteleon, A.; Koerner, M.; Becker-Gaab, C.; Reiser, M.; Wirth, S.

    2006-01-01

    The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p [de

  10. Atlas-guided generation of pseudo-CT images for MRI-only and hybrid PET-MRI-guided radiotherapy treatment planning

    DEFF Research Database (Denmark)

    Arabi, H.; Koutsouvelis, N.; Rouzaud, M.

    2016-01-01

    Magnetic resonance imaging (MRI)-guided attenuation correction (AC) of positron emission tomography (PET) data and/or radiation therapy (RT) treatment planning is challenged by the lack of a direct link between MRI voxel intensities and electron density. Therefore, even if this is not a trivial t......-CT images from conventional Dixon MRI sequences with improved bone extraction accuracy. The approach is promising for potential use in PET AC and MRI-only or hybrid PET/MRI-guided RT treatment planning. © 2016 Institute of Physics and Engineering in Medicine.......Magnetic resonance imaging (MRI)-guided attenuation correction (AC) of positron emission tomography (PET) data and/or radiation therapy (RT) treatment planning is challenged by the lack of a direct link between MRI voxel intensities and electron density. Therefore, even if this is not a trivial...... the conventional MRI segmentation technique and a recently proposed multi-atlas approach. The clinical studies consisted of pelvic CT, PET and MRI scans of 12 patients with loco-regionally advanced rectal disease. In the first step, bone segmentation of the target image is optimized through local weighted atlas...

  11. Initial clinical assessment of CT-MRI image fusion software in localization of the prostate for 3D conformal radiation therapy

    International Nuclear Information System (INIS)

    Kagawa, Kazufumi; Lee, W. Robert; Schultheiss, Timothy E.; Hunt, Margie A.; Shaer, Andrew H.; Hanks, Gerald E.

    1997-01-01

    Purpose: To assess the utility of image fusion software and compare MRI prostate localization with CT localization in patients undergoing 3D conformal radiation therapy of prostate cancer. Materials and Methods: After a phantom study was performed to ensure the accuracy of image fusion procedure, 22 prostate cancer patients had CT and MRI studies before the start of radiotherapy. Immobilization casts used during radiation treatment were also used for both imaging studies. After the clinical target volume (CTV) (prostate or prostate + seminal vesicles) was defined on CT, slices from the MRI study were reconstructed to precisely match the CT slices by identifying three common bony landmarks on each study. The CTV was separately defined on the matched MRI slices. Data related to the size and location of the prostate were compared between CT and MRI. The spatial relationship between the tip of urethrogram cone on CT and prostate apex seen on MRI was also estimated. Results: The phantom study showed the registration discrepancies between CT and MRI smaller than 1.0 mm in any pair in comparison. The patient study showed a mean image registration error of 0.9 (± 0.6) mm. The average prostate volume was 63.0 (± 25.8) cm 3 and 50.9 (± 22.9) cm 3 determined by CT and MRI, respectively. The difference in prostate location with the two studies usually differed at the base and at the apex of the prostate. On the transverse MRI, the prostate apex was situated 7.1 (± 4.5) mm dorsal and 15.1 (± 4.0) mm cephalad to the tip of urethrogram cone. Conclusions: CT-MRI image fusion study made it possible to compare the two modalities directly. MRI localization of the prostate is more accurate than CT, and indicates the distance from cone to apex is 15 mm. CT-MRI image fusion technique provides valuable supplements to CT technology for more precise targeting of the prostate cancer

  12. Imaging features of colovesical fistulae on MRI.

    Science.gov (United States)

    Tang, Y Z; Booth, T C; Swallow, D; Shahabuddin, K; Thomas, M; Hanbury, D; Chang, S; King, C

    2012-10-01

    MRI is routinely used in the investigation of colovesical fistulae at our institute. Several papers have alluded to its usefulness in achieving the diagnosis; however, there is a paucity of literature on its imaging findings. Our objective was to quantify the MRI characteristics of these fistulae. We selected all cases over a 4-year period with a final clinical diagnosis of colovesical fistula which had been investigated with MRI. The MRI scans were reviewed in a consensus fashion by two consultant uroradiologists. Their MRI features were quantified. There were 40 cases of colovesical fistulae. On MRI, the fistula morphology consistently fell into three patterns. The most common pattern (71%) demonstrated an intervening abscess between the bowel wall and bladder wall. The second pattern (15%) had a visible track between the affected bowel and bladder. The third pattern (13%) was a complete loss of fat plane between the affected bladder and bowel wall. MRI correctly determined the underlying aetiology in 63% of cases. MRI is a useful imaging modality in the diagnosis of colovesical fistulae. The fistulae appear to have three characteristic morphological patterns that may aid future diagnoses of colovesical fistulae. To the authors' knowledge, this is the first publication of the MRI findings in colovesical fistulae.

  13. Vision 20/20: Simultaneous CT-MRI — Next chapter of multimodality imaging

    International Nuclear Information System (INIS)

    Wang, Ge; Xi, Yan; Gjesteby, Lars; Getzin, Matthew; Yang, Qingsong; Cong, Wenxiang; Kalra, Mannudeep; Murugan, Venkatesh; Vannier, Michael

    2015-01-01

    Multimodality imaging systems such as positron emission tomography-computed tomography (PET-CT) and MRI-PET are widely available, but a simultaneous CT-MRI instrument has not been developed. Synergies between independent modalities, e.g., CT, MRI, and PET/SPECT can be realized with image registration, but such postprocessing suffers from registration errors that can be avoided with synchronized data acquisition. The clinical potential of simultaneous CT-MRI is significant, especially in cardiovascular and oncologic applications where studies of the vulnerable plaque, response to cancer therapy, and kinetic and dynamic mechanisms of targeted agents are limited by current imaging technologies. The rationale, feasibility, and realization of simultaneous CT-MRI are described in this perspective paper. The enabling technologies include interior tomography, unique gantry designs, open magnet and RF sequences, and source and detector adaptation. Based on the experience with PET-CT, PET-MRI, and MRI-LINAC instrumentation where hardware innovation and performance optimization were instrumental to construct commercial systems, the authors provide top-level concepts for simultaneous CT-MRI to meet clinical requirements and new challenges. Simultaneous CT-MRI fills a major gap of modality coupling and represents a key step toward the so-called “omnitomography” defined as the integration of all relevant imaging modalities for systems biology and precision medicine

  14. Vision 20/20: Simultaneous CT-MRI — Next chapter of multimodality imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ge, E-mail: wangg6@rpi.edu; Xi, Yan; Gjesteby, Lars; Getzin, Matthew; Yang, Qingsong; Cong, Wenxiang [Biomedical Imaging Center/Cluster, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States); Kalra, Mannudeep; Murugan, Venkatesh [Department of Imaging, Massachusetts General Hospital, 55 Fruit Street, Boston, Massachusetts 02114 (United States); Vannier, Michael [Department of Radiology, University of Chicago, Chicago, Illinois 60637 (United States)

    2015-10-15

    Multimodality imaging systems such as positron emission tomography-computed tomography (PET-CT) and MRI-PET are widely available, but a simultaneous CT-MRI instrument has not been developed. Synergies between independent modalities, e.g., CT, MRI, and PET/SPECT can be realized with image registration, but such postprocessing suffers from registration errors that can be avoided with synchronized data acquisition. The clinical potential of simultaneous CT-MRI is significant, especially in cardiovascular and oncologic applications where studies of the vulnerable plaque, response to cancer therapy, and kinetic and dynamic mechanisms of targeted agents are limited by current imaging technologies. The rationale, feasibility, and realization of simultaneous CT-MRI are described in this perspective paper. The enabling technologies include interior tomography, unique gantry designs, open magnet and RF sequences, and source and detector adaptation. Based on the experience with PET-CT, PET-MRI, and MRI-LINAC instrumentation where hardware innovation and performance optimization were instrumental to construct commercial systems, the authors provide top-level concepts for simultaneous CT-MRI to meet clinical requirements and new challenges. Simultaneous CT-MRI fills a major gap of modality coupling and represents a key step toward the so-called “omnitomography” defined as the integration of all relevant imaging modalities for systems biology and precision medicine.

  15. Reducing sedation for pediatric body MRI using accelerated and abbreviated imaging protocols

    International Nuclear Information System (INIS)

    Ahmad, Rizwan; Hu, Houchun Harry; Krishnamurthy, Ramkumar; Krishnamurthy, Rajesh

    2018-01-01

    Magnetic resonance imaging (MRI) is an established diagnostic imaging tool for investigating pediatric disease. MRI allows assessment of structure, function, and morphology in cardiovascular imaging, as well as tissue characterization in body imaging, without the use of ionizing radiation. For MRI in children, sedation and general anesthesia (GA) are often utilized to suppress patient motion, which can otherwise compromise image quality and diagnostic efficacy. However, evidence is emerging that use of sedation and GA in children might have long-term neurocognitive side effects, in addition to the short-term procedure-related risks. These concerns make risk-benefit assessment of sedation and GA more challenging. Therefore, reducing or eliminating the need for sedation and GA is an important goal of imaging innovation and research in pediatric MRI. In this review, the authors focus on technical and clinical approaches to reducing and eliminating the use of sedation in the pediatric population based on image acquisition acceleration and imaging protocols abbreviation. This paper covers important physiological and technical considerations for pediatric body MR imaging and discusses MRI techniques that offer the potential of recovering diagnostic-quality images from accelerated scans. In this review, the authors also introduce the concept of reporting elements for important indications for pediatric body MRI and use this as a basis for abbreviating the MR protocols. By employing appropriate accelerated and abbreviated approaches based on an understanding of the imaging needs and reporting elements for a given clinical indication, it is possible to reduce sedation and GA for pediatric chest, cardiovascular and abdominal MRI. (orig.)

  16. Reducing sedation for pediatric body MRI using accelerated and abbreviated imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Rizwan [The Ohio State University, Department of Biomedical Engineering, Columbus, OH (United States); Hu, Houchun Harry; Krishnamurthy, Ramkumar; Krishnamurthy, Rajesh [Nationwide Children' s Hospital, Department of Radiology, Columbus, OH (United States)

    2018-01-15

    Magnetic resonance imaging (MRI) is an established diagnostic imaging tool for investigating pediatric disease. MRI allows assessment of structure, function, and morphology in cardiovascular imaging, as well as tissue characterization in body imaging, without the use of ionizing radiation. For MRI in children, sedation and general anesthesia (GA) are often utilized to suppress patient motion, which can otherwise compromise image quality and diagnostic efficacy. However, evidence is emerging that use of sedation and GA in children might have long-term neurocognitive side effects, in addition to the short-term procedure-related risks. These concerns make risk-benefit assessment of sedation and GA more challenging. Therefore, reducing or eliminating the need for sedation and GA is an important goal of imaging innovation and research in pediatric MRI. In this review, the authors focus on technical and clinical approaches to reducing and eliminating the use of sedation in the pediatric population based on image acquisition acceleration and imaging protocols abbreviation. This paper covers important physiological and technical considerations for pediatric body MR imaging and discusses MRI techniques that offer the potential of recovering diagnostic-quality images from accelerated scans. In this review, the authors also introduce the concept of reporting elements for important indications for pediatric body MRI and use this as a basis for abbreviating the MR protocols. By employing appropriate accelerated and abbreviated approaches based on an understanding of the imaging needs and reporting elements for a given clinical indication, it is possible to reduce sedation and GA for pediatric chest, cardiovascular and abdominal MRI. (orig.)

  17. Clinical advantages of 3.0 T MRI over 1.5 T

    International Nuclear Information System (INIS)

    Willinek, Winfried A.; Schild, Hans H.

    2008-01-01

    Since approval by the FDA in 2000, human MR imaging (MRI) at 3.0 T has been increasingly used in clinical practice. In spite of the potential technical challenges, a number of clinical advantages of 3.0 T MRI over 1.5 T have been identified in the recent years. This article reviews the benefits and the current knowledge of 3.0 T whole-body MRI from an evidence-based perspective and summarizes its clinical applications

  18. Clinical advantages of 3.0 T MRI over 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Willinek, Winfried A. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)], E-mail: winfried.willinek@ukb.uni-bonn.de; Schild, Hans H. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)

    2008-01-15

    Since approval by the FDA in 2000, human MR imaging (MRI) at 3.0 T has been increasingly used in clinical practice. In spite of the potential technical challenges, a number of clinical advantages of 3.0 T MRI over 1.5 T have been identified in the recent years. This article reviews the benefits and the current knowledge of 3.0 T whole-body MRI from an evidence-based perspective and summarizes its clinical applications.

  19. Brain Tumor Image Segmentation in MRI Image

    Science.gov (United States)

    Peni Agustin Tjahyaningtijas, Hapsari

    2018-04-01

    Brain tumor segmentation plays an important role in medical image processing. Treatment of patients with brain tumors is highly dependent on early detection of these tumors. Early detection of brain tumors will improve the patient’s life chances. Diagnosis of brain tumors by experts usually use a manual segmentation that is difficult and time consuming because of the necessary automatic segmentation. Nowadays automatic segmentation is very populer and can be a solution to the problem of tumor brain segmentation with better performance. The purpose of this paper is to provide a review of MRI-based brain tumor segmentation methods. There are number of existing review papers, focusing on traditional methods for MRI-based brain tumor image segmentation. this paper, we focus on the recent trend of automatic segmentation in this field. First, an introduction to brain tumors and methods for brain tumor segmentation is given. Then, the state-of-the-art algorithms with a focus on recent trend of full automatic segmentaion are discussed. Finally, an assessment of the current state is presented and future developments to standardize MRI-based brain tumor segmentation methods into daily clinical routine are addressed.

  20. Clinical and MRI findings of brucellar spondylodiscitis

    International Nuclear Information System (INIS)

    Bozgeyik, Zulkif; Ozdemir, Huseyin; Demirdag, Kutbettin; Ozden, Mehmet; Sonmezgoz, Fitnet; Ozgocmen, Salih

    2008-01-01

    Objective: The aim of this retrospective study was to report the clinical features and MR imaging findings of patients with brucellar spondylodiscitis. Materials and methods: Twenty-two patients with spondylodiscitis, recruited among 152 patients with brucellosis referred from the Department of Infectious Diseases. Patients were diagnosed based on positive clinical findings, ≥1/160 titers of brucella agglutination tests and/or positive blood cultures. Magnetic resonance imaging (MRI) was performed to all of the patients with spondylodiscitis. Signal changes and enhancement of vertebral bodies, involvement of paravertebral soft tissues and epidural spaces, nerve root and cord compression and abscess formation were assessed. Results: All of the patients (n = 22; 7 F, 15 M) had ≥1/160 titers of brucella agglutination test and blood culture was positive in 9. A great majority of the patients had involvement at only one vertebrae level (n = 21, 95.5%), whereas one patient (4.5%) had multilevel involvement. In MRI, eight patients had soft tissue involvement and three had abscess formation. All cases had vertebral and discal enhancement. Additionally epidural extension was detected in four cases, posterior longitudinal ligament (PLL) elevation in five cases and root compression in two cases. Conclusion: Brucella is still a public health problem in endemic areas. MRI is a highly sensitive and non-invasive imaging technique which should be first choice of imaging in the early diagnosis of spondylodiscitis

  1. Clinical and MRI findings of brucellar spondylodiscitis

    Energy Technology Data Exchange (ETDEWEB)

    Bozgeyik, Zulkif [Department of Radiology, Faculty of Medicine, Firat University, 23119 Elazig (Turkey)], E-mail: bozgeyik4@hotmail.com; Ozdemir, Huseyin [Department of Radiology, Faculty of Medicine, Firat University, 23119 Elazig (Turkey); Demirdag, Kutbettin; Ozden, Mehmet [Department of Infection Disease, Faculty of Medicine, Firat University, Elazig (Turkey); Sonmezgoz, Fitnet [Department of Radiology, Faculty of Medicine, Firat University, 23119 Elazig (Turkey); Ozgocmen, Salih [Division of Rheumatology, Department of PMR, Faculty of Medicine, Firat University, Elazig (Turkey)

    2008-07-15

    Objective: The aim of this retrospective study was to report the clinical features and MR imaging findings of patients with brucellar spondylodiscitis. Materials and methods: Twenty-two patients with spondylodiscitis, recruited among 152 patients with brucellosis referred from the Department of Infectious Diseases. Patients were diagnosed based on positive clinical findings, {>=}1/160 titers of brucella agglutination tests and/or positive blood cultures. Magnetic resonance imaging (MRI) was performed to all of the patients with spondylodiscitis. Signal changes and enhancement of vertebral bodies, involvement of paravertebral soft tissues and epidural spaces, nerve root and cord compression and abscess formation were assessed. Results: All of the patients (n = 22; 7 F, 15 M) had {>=}1/160 titers of brucella agglutination test and blood culture was positive in 9. A great majority of the patients had involvement at only one vertebrae level (n = 21, 95.5%), whereas one patient (4.5%) had multilevel involvement. In MRI, eight patients had soft tissue involvement and three had abscess formation. All cases had vertebral and discal enhancement. Additionally epidural extension was detected in four cases, posterior longitudinal ligament (PLL) elevation in five cases and root compression in two cases. Conclusion: Brucella is still a public health problem in endemic areas. MRI is a highly sensitive and non-invasive imaging technique which should be first choice of imaging in the early diagnosis of spondylodiscitis.

  2. MRI for clinically suspected pediatric appendicitis: an implemented program

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Michael M.; Gustas, Cristy N.; Choudhary, Arabinda K.; Methratta, Sosamma T.; Hulse, Michael A.; Eggli, Kathleen D.; Boal, Danielle K.B. [Penn State Milton S. Hershey Medical Center, Department of Radiology, Mail Code H066, 500 University Drive, P.O. Box 850, Hershey, PA (United States); Geeting, Glenn [Penn State Milton S. Hershey Medical Center, Department of Emergency Medicine, Hershey, PA (United States)

    2012-09-15

    Emergent MRI is now a viable alternative to CT for evaluating appendicitis while avoiding the detrimental effects of ionizing radiation. However, primary employment of MRI in the setting of clinically suspected pediatric appendicitis has remained significantly underutilized. To describe our institution's development and the results of a fully implemented clinical program using MRI as the primary imaging evaluation for children with suspected appendicitis. A four-sequence MRI protocol consisting of coronal and axial single-shot turbo spin-echo (SS-TSE) T2, coronal spectral adiabatic inversion recovery (SPAIR), and axial SS-TSE T2 with fat saturation was performed on 208 children, ages 3 to 17 years, with clinically suspected appendicitis. No intravenous or oral contrast material was administered. No sedation was administered. Data collection includes two separate areas: time parameter analysis and MRI diagnostic results. Diagnostic accuracy of MRI for pediatric appendicitis indicated a sensitivity of 97.6% (CI: 87.1-99.9%), specificity 97.0% (CI: 93.2-99.0%), positive predictive value 88.9% (CI: 76.0-96.3%), and negative predictive value 99.4% (CI: 96.6-99.9%). Time parameter analysis indicated clinical feasibility, with time requested to first sequence obtained mean of 78.7 +/- 52.5 min, median 65 min; first-to-last sequence time stamp mean 14.2 +/- 8.8 min, median 12 min; last sequence to report mean 57.4 +/- 35.2 min, median 46 min. Mean age was 11.2 +/- 3.6 years old. Girls represented 57% of patients. MRI is an effective and efficient method of imaging children with clinically suspected appendicitis. Using an expedited four-sequence protocol, sensitivity and specificity are comparable to CT while avoiding the detrimental effects of ionizing radiation. (orig.)

  3. Wavelet-based de-noising algorithm for images acquired with parallel magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Delakis, Ioannis; Hammad, Omer; Kitney, Richard I

    2007-01-01

    Wavelet-based de-noising has been shown to improve image signal-to-noise ratio in magnetic resonance imaging (MRI) while maintaining spatial resolution. Wavelet-based de-noising techniques typically implemented in MRI require that noise displays uniform spatial distribution. However, images acquired with parallel MRI have spatially varying noise levels. In this work, a new algorithm for filtering images with parallel MRI is presented. The proposed algorithm extracts the edges from the original image and then generates a noise map from the wavelet coefficients at finer scales. The noise map is zeroed at locations where edges have been detected and directional analysis is also used to calculate noise in regions of low-contrast edges that may not have been detected. The new methodology was applied on phantom and brain images and compared with other applicable de-noising techniques. The performance of the proposed algorithm was shown to be comparable with other techniques in central areas of the images, where noise levels are high. In addition, finer details and edges were maintained in peripheral areas, where noise levels are low. The proposed methodology is fully automated and can be applied on final reconstructed images without requiring sensitivity profiles or noise matrices of the receiver coils, therefore making it suitable for implementation in a clinical MRI setting

  4. Multiparametric and molecular imaging of breast tumors with MRI and PET/MRI

    International Nuclear Information System (INIS)

    Pinker, K.; Marino, M.A.; Meyer-Baese, A.; Helbich, T.H.

    2016-01-01

    Magnetic resonance imaging (MRI) of the breast is an indispensable tool in breast imaging for many indications. Several functional parameters with MRI and positron emission tomography (PET) have been assessed for imaging of breast tumors and their combined application is defined as multiparametric imaging. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the hallmarks of cancer and may provide additional specificity. Multiparametric and molecular imaging of the breast comprises established MRI parameters, such as dynamic contrast-enhanced MRI, diffusion-weighted imaging (DWI), MR proton spectroscopy ( 1 H-MRSI) as well as combinations of radiological and MRI techniques (e.g. PET/CT and PET/MRI) using radiotracers, such as fluorodeoxyglucose (FDG). Multiparametric and molecular imaging of the breast can be performed at different field-strengths (range 1.5-7 T). Emerging parameters comprise novel promising techniques, such as sodium imaging ( 23 Na MRI), phosphorus spectroscopy ( 31 P-MRSI), chemical exchange saturation transfer (CEST) imaging, blood oxygen level-dependent (BOLD) and hyperpolarized MRI as well as various specific radiotracers. Multiparametric and molecular imaging has multiple applications in breast imaging. Multiparametric and molecular imaging of the breast is an evolving field that will enable improved detection, characterization, staging and monitoring for personalized medicine in breast cancer. (orig.) [de

  5. WE-DE-206-03: MRI Image Formation - Slice Selection, Phase Encoding, Frequency Encoding, K-Space, SNR

    International Nuclear Information System (INIS)

    Lin, C.

    2016-01-01

    Magnetic resonance imaging (MRI) has become an essential part of clinical imaging due to its ability to render high soft tissue contrast. Instead of ionizing radiation, MRI use strong magnetic field, radio frequency waves and field gradients to create diagnostic useful images. It can be used to image the anatomy and also functional and physiological activities within the human body. Knowledge of the basic physical principles underlying MRI acquisition is vitally important to successful image production and proper image interpretation. This lecture will give an overview of the spin physics, imaging principle of MRI, the hardware of the MRI scanner, and various pulse sequences and their applications. It aims to provide a conceptual foundation to understand the image formation process of a clinical MRI scanner. Learning Objectives: Understand the origin of the MR signal and contrast from the spin physics level. Understand the main hardware components of a MRI scanner and their purposes Understand steps for MR image formation including spatial encoding and image reconstruction Understand the main kinds of MR pulse sequences and their characteristics.

  6. WE-DE-206-03: MRI Image Formation - Slice Selection, Phase Encoding, Frequency Encoding, K-Space, SNR

    Energy Technology Data Exchange (ETDEWEB)

    Lin, C. [Indiana University School of Medicine (United States)

    2016-06-15

    Magnetic resonance imaging (MRI) has become an essential part of clinical imaging due to its ability to render high soft tissue contrast. Instead of ionizing radiation, MRI use strong magnetic field, radio frequency waves and field gradients to create diagnostic useful images. It can be used to image the anatomy and also functional and physiological activities within the human body. Knowledge of the basic physical principles underlying MRI acquisition is vitally important to successful image production and proper image interpretation. This lecture will give an overview of the spin physics, imaging principle of MRI, the hardware of the MRI scanner, and various pulse sequences and their applications. It aims to provide a conceptual foundation to understand the image formation process of a clinical MRI scanner. Learning Objectives: Understand the origin of the MR signal and contrast from the spin physics level. Understand the main hardware components of a MRI scanner and their purposes Understand steps for MR image formation including spatial encoding and image reconstruction Understand the main kinds of MR pulse sequences and their characteristics.

  7. Spectrum of MRI findings in clinical athletic pubalgia.

    Science.gov (United States)

    Zajick, Donald C; Zoga, Adam C; Omar, Imran M; Meyers, William C

    2008-03-01

    Athletic pubalgia is a frequently encountered syndrome for clinicians who treat active patients participating in a wide variety of athletic endeavors worldwide. Pathologies associated with this clinical scenario span anatomically from the pubic symphysis to the hip and include a myriad of poorly understood and incompletely described musculoskeletal entities, many of which are centered about the pubic symphysis and its tendinous attachments. In this article, we discuss the relevant anatomy and pathophysiology for the most frequently encountered of these disorders, using magnetic resonance (MR) images as a guide. We describe an MR imaging protocol tailored to clinical athletic pubalgia. We then review reproducible MRI patterns of pathology about the pubic symphysis, the rectus abdominis/adductor aponeurosis and the inguinal ring, as well as a group of clinically confounding entities remote from the symphysis but visible by MRI.

  8. [Clinical evaluation of female pelvic tumors : Application fields of integrated PET/MRI].

    Science.gov (United States)

    Grueneisen, J; Umutlu, L

    2016-07-01

    Integrated positron emission tomography (PET) and magnetic resonance imaging (MRI) scanning has recently become established in clinical imaging. Various studies have demonstrated the great potential of this new hybrid imaging procedure for applications in the field of oncology and the diagnostics of inflammatory processes. With initial studies demonstrating the feasibility and high diagnostic potential of PET/MRI comparable to PET-computed tomography (CT), the focus of future studies should be on the identification of application fields with a potential diagnostic benefit of PET/MRI over other established diagnostic tools. Both MRI and PET/CT are widely used in the diagnostic algorithms for malignancies of the female pelvis. A simultaneous acquisition of PET and MRI data within a single examination provides complementary information which can be used for a more comprehensive evaluation of the primary tumor as well as for whole body staging. Therefore, the aim of this article is to outline potential clinical applications of integrated PET/MRI for the diagnostic work-up of primary or recurrent gynecological neoplasms of the female pelvis.

  9. Guidelines for imaging retinoblastoma: imaging principles and MRI standardization

    Energy Technology Data Exchange (ETDEWEB)

    Graaf, Pim de; Rodjan, Firazia; Castelijns, Jonas A. [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Goericke, Sophia [University Hospital, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Galluzzi, Paolo [Azienda Ospedaliera e Universitaria Senese, Policlinico ' ' Le Scotte' ' , Unit of Diagnostic and Therapeutic Neuroradiology, Siena (Italy); Maeder, Philippe [CHUV, Service de Radiodiagnostic et Radiologie Interventionelle, Lausanne (Switzerland); Brisse, Herve J. [Institut Curie, Departement d' Imagerie, Paris (France)

    2012-01-15

    Retinoblastoma is the most common intraocular tumor in children. The diagnosis is usually established by the ophthalmologist on the basis of fundoscopy and US. Together with US, high-resolution MRI has emerged as an important imaging modality for pretreatment assessment, i.e. for diagnostic confirmation, detection of local tumor extent, detection of associated developmental malformation of the brain and detection of associated intracranial primitive neuroectodermal tumor (trilateral retinoblastoma). Minimum requirements for pretreatment diagnostic evaluation of retinoblastoma or mimicking lesions are presented, based on consensus among members of the European Retinoblastoma Imaging Collaboration (ERIC). The most appropriate techniques for imaging in a child with leukocoria are reviewed. CT is no longer recommended. Implementation of a standardized MRI protocol for retinoblastoma in clinical practice may benefit children worldwide, especially those with hereditary retinoblastoma, since a decreased use of CT reduces the exposure to ionizing radiation. (orig.)

  10. 7T MRI in focal epilepsy with unrevealing conventional field strength imaging.

    Science.gov (United States)

    De Ciantis, Alessio; Barba, Carmen; Tassi, Laura; Cosottini, Mirco; Tosetti, Michela; Costagli, Mauro; Bramerio, Manuela; Bartolini, Emanuele; Biagi, Laura; Cossu, Massimo; Pelliccia, Veronica; Symms, Mark R; Guerrini, Renzo

    2016-03-01

    To assess the diagnostic yield of 7T magnetic resonance imaging (MRI) in detecting and characterizing structural lesions in patients with intractable focal epilepsy and unrevealing conventional (1.5 or 3T) MRI. We conducted an observational clinical imaging study on 21 patients (17 adults and 4 children) with intractable focal epilepsy, exhibiting clinical and electroencephalographic features consistent with a single seizure-onset zone (SOZ) and unrevealing conventional MRI. Patients were enrolled at two tertiary epilepsy surgery centers and imaged at 7T, including whole brain (three-dimensional [3D] T1 -weighted [T1W] fast-spoiled gradient echo (FSPGR), 3D susceptibility-weighted angiography [SWAN], 3D fluid-attenuated inversion recovery [FLAIR]) and targeted imaging (2D T2*-weighted dual-echo gradient-recalled echo [GRE] and 2D gray-white matter tissue border enhancement [TBE] fast spin echo inversion recovery [FSE-IR]). MRI studies at 1.5 or 3T deemed unrevealing at the referral center were reviewed by three experts in epilepsy imaging. Reviewers were provided information regarding the suspected localization of the SOZ. The same team subsequently reviewed 7T images. Agreement in imaging interpretation was reached through consensus-based discussions based on visual identification of structural abnormalities and their likely correlation with clinical and electrographic data. 7T MRI revealed structural lesions in 6 (29%) of 21 patients. The diagnostic gain in detection was obtained using GRE and FLAIR images. Four of the six patients with abnormal 7T underwent epilepsy surgery. Histopathology revealed focal cortical dysplasia (FCD) in all. In the remaining 15 patients (71%), 7T MRI remained unrevealing; 4 of the patients underwent epilepsy surgery and histopathologic evaluation revealed gliosis. 7T MRI improves detection of epileptogenic FCD that is not visible at conventional field strengths. A dedicated protocol including whole brain FLAIR and GRE images at 7T

  11. Magnetic resonance imaging (MRI) of avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Kokubo, Takashi; Yoshikawa, Kohki; Aoki, Shigeki

    1987-01-01

    Thirty-seven patients with the clinical diagnosis of or suspicious of avascular necrosis (AN) of the femoral head were examined by magnetic resonance imaging (MRI). In all patients with AN confirmed from clinical symptoms, past history and plain radiographs, MRI demonstrated abnormal low intensity area in the necrosed femoral head. The abnormal findings on MRI were divided into three patterns: low signal intensity occupying the greater part of the femoral head (type A), low signal intensity localized in the periphery (type B), ring-shaped or band-like low signal intensity (type C). No correlation was found among MRI patterns, radiographic findings and radionuclide bone scan images, except that the type C was not found in the stage IV determined radiographically. In the patients suspicious of AN, the positive rate of MRI was higher than that of radionuclide scan. Abnormal findings on only MRI may not necessarily indicate AN. However, such a patient must be kept under observation, because the possibility exists that only MRI detects early or asymptomatic AN of the femoral head. (author)

  12. Magnetic resonance imaging (MRI) of avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Kokubo, Takashi; Yoshikawa, Kohki; Aoki, Shigeki

    1987-05-01

    Thirty-seven patients with the clinical diagnosis of or suspicious of avascular necrosis (AN) of the femoral head were examined by magnetic resonance imaging (MRI). In all patients with AN confirmed from clinical symptoms, past history and plain radiographs, MRI demonstrated abnormal low intensity area in the necrosed femoral head. The abnormal findings on MRI were divided into three patterns: low signal intensity occupying the greater part of the femoral head (type A), low signal intensity localized in the periphery (type B), ring-shaped or band-like low signal intensity (type C). No correlation was found among MRI patterns, radiographic findings and radionuclide bone scan images, except that the type C was not found in the stage IV determined radiographically. In the patients suspicious of AN, the positive rate of MRI was higher than that of radionuclide scan. Abnormal findings on only MRI may not necessarily indicate AN. However, such a patient must be kept under observation, because the possibility exists that only MRI detects early or asymptomatic AN of the femoral head.

  13. MRI and CBCT image registration of temporomandibular joint: a systematic review.

    Science.gov (United States)

    Al-Saleh, Mohammed A Q; Alsufyani, Noura A; Saltaji, Humam; Jaremko, Jacob L; Major, Paul W

    2016-05-10

    The purpose of the present review is to systematically and critically analyze the available literature regarding the importance, applicability, and practicality of (MRI), computerized tomography (CT) or cone-beam CT (CBCT) image registration for TMJ anatomy and assessment. A systematic search of 4 databases; MEDLINE, EMBASE, EBM reviews and Scopus, was conducted by 2 reviewers. An additional manual search of the bibliography was performed. All articles discussing the magnetic resonance imaging MRI and CT or CBCT image registration for temporomandibular joint (TMJ) visualization or assessment were included. Only 3 articles satisfied the inclusion criteria. All included articles were published within the last 7 years. Two articles described MRI to CT multimodality image registration as a complementary tool to visualize TMJ. Both articles used images of one patient only to introduce the complementary concept of MRI-CT fused image. One article assessed the reliability of using MRI-CBCT registration to evaluate the TMJ disc position and osseous pathology for 10 temporomandibular disorder (TMD) patients. There are very limited studies of MRI-CT/CBCT registration to reach a conclusion regarding its accuracy or clinical use in the temporomandibular joints.

  14. Reducing acquisition time in clinical MRI by data undersampling and compressed sensing reconstruction

    Science.gov (United States)

    Hollingsworth, Kieren Grant

    2015-11-01

    MRI is often the most sensitive or appropriate technique for important measurements in clinical diagnosis and research, but lengthy acquisition times limit its use due to cost and considerations of patient comfort and compliance. Once an image field of view and resolution is chosen, the minimum scan acquisition time is normally fixed by the amount of raw data that must be acquired to meet the Nyquist criteria. Recently, there has been research interest in using the theory of compressed sensing (CS) in MR imaging to reduce scan acquisition times. The theory argues that if our target MR image is sparse, having signal information in only a small proportion of pixels (like an angiogram), or if the image can be mathematically transformed to be sparse then it is possible to use that sparsity to recover a high definition image from substantially less acquired data. This review starts by considering methods of k-space undersampling which have already been incorporated into routine clinical imaging (partial Fourier imaging and parallel imaging), and then explains the basis of using compressed sensing in MRI. The practical considerations of applying CS to MRI acquisitions are discussed, such as designing k-space undersampling schemes, optimizing adjustable parameters in reconstructions and exploiting the power of combined compressed sensing and parallel imaging (CS-PI). A selection of clinical applications that have used CS and CS-PI prospectively are considered. The review concludes by signposting other imaging acceleration techniques under present development before concluding with a consideration of the potential impact and obstacles to bringing compressed sensing into routine use in clinical MRI.

  15. Brain tumor segmentation using holistically nested neural networks in MRI images.

    Science.gov (United States)

    Zhuge, Ying; Krauze, Andra V; Ning, Holly; Cheng, Jason Y; Arora, Barbara C; Camphausen, Kevin; Miller, Robert W

    2017-10-01

    Gliomas are rapidly progressive, neurologically devastating, largely fatal brain tumors. Magnetic resonance imaging (MRI) is a widely used technique employed in the diagnosis and management of gliomas in clinical practice. MRI is also the standard imaging modality used to delineate the brain tumor target as part of treatment planning for the administration of radiation therapy. Despite more than 20 yr of research and development, computational brain tumor segmentation in MRI images remains a challenging task. We are presenting a novel method of automatic image segmentation based on holistically nested neural networks that could be employed for brain tumor segmentation of MRI images. Two preprocessing techniques were applied to MRI images. The N4ITK method was employed for correction of bias field distortion. A novel landmark-based intensity normalization method was developed so that tissue types have a similar intensity scale in images of different subjects for the same MRI protocol. The holistically nested neural networks (HNN), which extend from the convolutional neural networks (CNN) with a deep supervision through an additional weighted-fusion output layer, was trained to learn the multiscale and multilevel hierarchical appearance representation of the brain tumor in MRI images and was subsequently applied to produce a prediction map of the brain tumor on test images. Finally, the brain tumor was obtained through an optimum thresholding on the prediction map. The proposed method was evaluated on both the Multimodal Brain Tumor Image Segmentation (BRATS) Benchmark 2013 training datasets, and clinical data from our institute. A dice similarity coefficient (DSC) and sensitivity of 0.78 and 0.81 were achieved on 20 BRATS 2013 training datasets with high-grade gliomas (HGG), based on a two-fold cross-validation. The HNN model built on the BRATS 2013 training data was applied to ten clinical datasets with HGG from a locally developed database. DSC and sensitivity of

  16. Incidental abdominopelvic findings on expanded field-of-view lumbar spinal MRI: frequency, clinical importance, and concordance in interpretation by neuroimaging and body imaging radiologists

    International Nuclear Information System (INIS)

    Maxwell, A.W.P.; Keating, D.P.; Nickerson, J.P.

    2015-01-01

    Aim: To characterize the frequency of identification, clinical importance, and concordance in interpretation of incidental abdominopelvic findings identified on routine lumbar spinal MRI using supplemental expanded field-of-view (FOV) coronal imaging. Materials and methods: All lumbar spinal MRI reports over a 12-month period were retrospectively reviewed for the presence of incidental abdominopelvic findings identified using expanded FOV coronal imaging. Medical records were used to identify those findings that received follow-up, which were then categorized according to final diagnosis and classified as “indeterminate,” “likely clinically unimportant,” and “likely clinically important”. All cases that received follow-up were blindly and independently re-reviewed by a neuroimaging radiologist and body-imaging radiologist, and reviewer performances were compared to assess for agreement with regard to lesion significance, need for follow-up, and other parameters. Results: In total, 2067 reports were reviewed: 687 (33.2%) featured one or more incidental abdominopelvic findings, and 102 (4.9%) findings received further evaluation. Of these, 11 (10.9%) were classified as “indeterminate,” 50 (49%) as “likely clinically unimportant,” and 41 (40.1%) were classified as “likely clinically important.” Excellent agreement was observed between the reviewing radiologists for all evaluated parameters. Conclusion: The addition of an expanded FOV coronal sequence to the standard lumbar spinal MRI protocol was associated with the identification of a large number of incidental abdominopelvic findings, the minority of which represent likely clinically important findings. Most incidental findings were confidently dismissed by a neuroimaging radiologist as likely clinically unimportant without utilization of additional clinical or radiographic resources. - Highlights: • Expanded field-of-view (FOV) MRI improves detection of important incidental findings.

  17. Software Toolbox for Low-Frequency Conductivity and Current Density Imaging Using MRI.

    Science.gov (United States)

    Sajib, Saurav Z K; Katoch, Nitish; Kim, Hyung Joong; Kwon, Oh In; Woo, Eung Je

    2017-11-01

    Low-frequency conductivity and current density imaging using MRI includes magnetic resonance electrical impedance tomography (MREIT), diffusion tensor MREIT (DT-MREIT), conductivity tensor imaging (CTI), and magnetic resonance current density imaging (MRCDI). MRCDI and MREIT provide current density and isotropic conductivity images, respectively, using current-injection phase MRI techniques. DT-MREIT produces anisotropic conductivity tensor images by incorporating diffusion weighted MRI into MREIT. These current-injection techniques are finding clinical applications in diagnostic imaging and also in transcranial direct current stimulation (tDCS), deep brain stimulation (DBS), and electroporation where treatment currents can function as imaging currents. To avoid adverse effects of nerve and muscle stimulations due to injected currents, conductivity tensor imaging (CTI) utilizes B1 mapping and multi-b diffusion weighted MRI to produce low-frequency anisotropic conductivity tensor images without injecting current. This paper describes numerical implementations of several key mathematical functions for conductivity and current density image reconstructions in MRCDI, MREIT, DT-MREIT, and CTI. To facilitate experimental studies of clinical applications, we developed a software toolbox for these low-frequency conductivity and current density imaging methods. This MR-based conductivity imaging (MRCI) toolbox includes 11 toolbox functions which can be used in the MATLAB environment. The MRCI toolbox is available at http://iirc.khu.ac.kr/software.html . Its functions were tested by using several experimental datasets, which are provided together with the toolbox. Users of the toolbox can focus on experimental designs and interpretations of reconstructed images instead of developing their own image reconstruction softwares. We expect more toolbox functions to be added from future research outcomes. Low-frequency conductivity and current density imaging using MRI includes

  18. MO-FG-207-03: Maximizing the Utility of Integrated PET/MRI in Clinical Applications

    Energy Technology Data Exchange (ETDEWEB)

    Behr, S. [University of California (United States)

    2015-06-15

    The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

  19. MO-FG-207-03: Maximizing the Utility of Integrated PET/MRI in Clinical Applications

    International Nuclear Information System (INIS)

    Behr, S.

    2015-01-01

    The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee

  20. Clinical utility of simultaneous whole-body 18F-FDG PET/MRI as a single-step imaging modality in the staging of primary nasopharyngeal carcinoma.

    Science.gov (United States)

    Chan, Sheng-Chieh; Yeh, Chih-Hua; Yen, Tzu-Chen; Ng, Shu-Hang; Chang, Joseph Tung-Chieh; Lin, Chien-Yu; Yen-Ming, Tsang; Fan, Kang-Hsing; Huang, Bing-Shen; Hsu, Cheng-Lung; Chang, Kai-Ping; Wang, Hung-Ming; Liao, Chun-Ta

    2018-03-03

    Both head and neck magnetic resonance imaging (MRI) and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) play a crucial role in the staging of primary nasopharyngeal carcinoma (NPC). In this study, we sought to prospectively investigate the clinical utility of simultaneous whole-body 18F-FDG PET/MRI for primary staging of NPC patients. We examined 113 patients with histologically confirmed NPC who underwent pretreatment, simultaneous whole-body PET/MRI and PET/CT for primary tumor staging. The images obtained with the different imaging modalities were interpreted independently and compared with each other. PET/MRI increased the accuracy of head and neck MRI for assessment of primary tumor extent in four patients via addition of FDG uptake information to increase the conspicuity of morphologically subtle lesions. PET/MR images were more discernible than PET/CT images for mapping tumor extension, especially intracranial invasion. Regarding the N staging assessment, the sensitivity of PET/MRI (99.5%) was higher than that of head and neck MRI (94.2%) and PET/CT (90.9%). PET/MRI was particularly useful for distinguishing retropharyngeal nodal metastasis from adjacent nasopharyngeal tumors. For distant metastasis evaluation, PET/MRI exhibited a similar sensitivity (90% vs. 86.7% vs. 83.3%), but higher positive predictive value (93.1% vs. 78.8% vs. 83.3%) than whole-body MRI and PET/CT, respectively. For tumor staging of NPC, simultaneous whole-body PET/MRI was more accurate than head and neck MRI and PET/CT, and may serve as a single-step staging modality.

  1. Phase-encoded MRI for geometrically undistorted imaging and signal characterization

    NARCIS (Netherlands)

    van Gorp, JS

    2016-01-01

    Magnetic resonance imaging (MRI) is a versatile diagnostic modality that has earned its place in clinical practice all over the world. MRI delivers excellent soft-tissue contrast that can be utilized to detect disease and measure physiological properties in a non-invasive manner. As long as the main

  2. PET/MRI for Oncologic Brain Imaging

    DEFF Research Database (Denmark)

    Rausch, Ivo; Rischka, Lucas; Ladefoged, Claes N

    2017-01-01

    The aim of this study was to compare attenuation-correction (AC) approaches for PET/MRI in clinical neurooncology.Methods:Forty-nine PET/MRI brain scans were included: brain tumor studies using18F-fluoro-ethyl-tyrosine (18F-FET) (n= 31) and68Ga-DOTANOC (n= 7) and studies of healthy subjects using18...... by Siemens Healthcare). As a reference, AC maps were derived from patient-specific CT images (CTref). PET data were reconstructed using standard settings after AC with all 4 AC methods. We report changes in diagnosis for all brain tumor patients and the following relative differences values (RDs...... of the whole brain and 10 anatomic regions segmented on MR images.Results:For brain tumor imaging (A and B), the standard PET-based diagnosis was not affected by any of the 3 MR-AC methods. For A, the average RDs of SUVmeanwere -10%, -4%, and -3% and of the VOIs 1%, 2%, and 7% for DIXON, UTE, and BD...

  3. The impact of MRI on the clinical management of inflammatory arthritides

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Ulrich [University of Alberta, Department of Medicine, Division of Rheumatology, Edmonton, AB (Canada); Balgrist University Hospital, Department of Rheumatology, Zurich (Switzerland); Oestergaard, Mikkel [Copenhagen University Hospital at Glostrup, Department of Rheumatology, Copenhagen (Denmark); Lambert, Robert G.W. [University of Alberta, Department of Radiology and Diagnostic Imaging, Edmonton, AB (Canada); Maksymowych, Walter P. [University of Alberta, Department of Medicine, Division of Rheumatology, Edmonton, AB (Canada)

    2011-09-15

    In the past two decades, MRI has gained a major role in research and clinical management of patients with inflammatory arthritides, particularly in spondyloarthritis (SpA), rheumatoid arthritis (RA), and osteoarthritis (OA). MRI is regarded as the most sensitive imaging modality for detecting early SpA in young patients with inflammatory back pain and normal radiographs of the sacroiliac joints. The recently published Assessment of SpondyloArthritis International Society classification criteria for axial SpA include for the first time a positive MRI demonstrating sacroiliitis as an imaging criterion indicative of SpA together with at least one clinical feature of SpA. Recent data show that systematic assessment of sacroiliitis displayed on MRI has much greater diagnostic utility than previously reported and highlight the diagnostic relevance of structural lesions. In RA, MRI has predictive value for the development of disease in new onset undifferentiated arthritis, and MR pathology at disease onset is a highly significant predictor of radiographic erosions. Consequently MRI has been credited with an important role in the new ACR/EULAR 2010 classification criteria for RA. In OA, bone marrow edema (BME) and synovitis may serve as biomarkers in interventional trials. Treatment interventions targeting BME and synovitis observed on MRI in inflammatory arthritides may have a disease-modifying effect as these lesions are potentially reversible and have been shown to be associated with structural progression. Research should focus on the prognostic significance of MRI lesions in larger cohorts and whether adding MRI to routine care improves clinical and radiographic outcome in patients with inflammatory arthritides. (orig.)

  4. The establishment of a multiple sclerosis model for clinical MRI study

    International Nuclear Information System (INIS)

    Zhang Haiqin; Li Kuncheng; Yu Chunshui; Ma Jia; Qin Wen; Ji Zhijuan; Piao Yueshan

    2009-01-01

    Objective: To establish a rat model of multiple sclerosis (MS) for clinical MRI study. Methods: The Lewis (LEW) rats were immunized by myelin oligodendrocyte glycoprotein peptide 35-55 (MOG 35-55 ) emulsified with complete Freunds adjuvant/incomplete Freunds adjuvant. Twenty LEW rats were selected. Group A rats were 5, group B rats were 10 and control group rats were 5. MRI and histopathology analysis were observed on group A and control group, and clinical course were observed on group B. The clinical course was observed and the brain and spinal cord of EAE rats were scanned on 3.0 T MR system with quadrature wrist joint coil on the third day of the acute stage of disease. The T 2 /T 1 weighted images and Gadolinium enhanced T 1 weighted images in 3D volume were obtained respectively. The magnetization transfer ratio (MTR) images were calculated with special software in workstation. Rats were sacrificed within 24 h after MRI, and the histopathological changes of central nervous system were observed. Results: Twice immunization of MOG 35-55 was used and a rat model of MS was successfully induced with all the rats. The model had varied clinical symptoms. The lesions of central nervous system at acute stage on group A (5 rats) were depicted on MRI. The lesions located in the brain and the spinal cord with main manifestation of hyperintensity on T 2 weighed images and hypointensity on T 1 weighted images. Some lesions had Gd-DTPA enhancement, and the value of MTR decreased. The infiltration of mononuclear cells around blood vessels and the extensive distribution of lesions of demyelination in brain and spinal cord were verified by histological examination. Conclusions: Twice immunization of MOG 35-55 could produce a rat model which mimics MS. The model is stable with higher incidence, and the antigen is cheap and obtained easily. The intravital monitoring of brain and spinal cord lesions in MOG 35-55 induced rat model is possible on 3.0 T clinical whole- body MR

  5. Clinical Utility of Magnetic Resonance Imaging (MRI) and Ultrasonography (US) for Diagnosis of Polycystic Ovary Syndrome (PCOS) in Adolescent Girls

    Science.gov (United States)

    Kenigsberg, Lisa E; Agarwal, Chhavi; Sin, Sanghun; Shifteh, Keivan; Isasi, Carmen R; Crespi, Rebecca; Ivanova, Janeta; Coupey, Susan M; Heptulla, Rubina A; Arens, Raanan

    2015-01-01

    Objectives Evaluate ovarian morphology using 3-dimensional MRI in adolescent girls with and without PCOS. Compare the utility of MRI versus ultrasonography (US) for diagnosis of PCOS Design Cross-sectional Setting Urban academic tertiary-care children’s hospital Patients Thirty-nine adolescent girls with untreated PCOS and 22 age/BMI-matched controls. Intervention MRI and/or transvaginal/transabdominal US Main Outcome Measure Ovarian volume (OV); follicle number per section (FNPS); correlation between OV on MRI and US; proportion of subjects with features of polycystic ovaries on MRI and US. Results MRI demonstrated larger OV and higher FNPS in subjects with PCOS compared to controls. Within the PCOS group, median OV was 11.9 (7.7) cm3 by MRI, compared with 8.8 (7.8) cm3 by US. Correlation coefficient between OV by MRI and US was 0.701. Due to poor resolution, FNPS could not be determined by US or compared with MRI. ROC curve analysis for MRI demonstrated that increasing volume cut-offs for polycystic ovaries from 10cm3 to 14cm3, increased specificity from 77% to 95%. For FNPS on MRI, specificity increased from 82% to 98% by increasing cut-offs from ≥12 to ≥17. Using Rotterdam cut-offs, 91% of subjects with PCOS met polycystic ovary criteria on MRI, while only 52% met criteria by US. Conclusions US measures smaller OV than MRI, cannot accurately detect follicle number, and is a poor imaging modality for characterizing polycystic ovaries in adolescents with suspected PCOS. For adolescents in whom diagnosis of PCOS remains uncertain after clinical and laboratory evaluation, MRI should be considered as a diagnostic imaging modality. PMID:26354095

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... to a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive imaging ... over time. top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... claustrophobia. Newer open MRI units provide very high quality images for many types of exams. Older open MRI units may not provide this same image quality. Certain types of exams cannot be performed using ...

  8. Pharmaceutical applications of magnetic resonance imaging (MRI).

    Science.gov (United States)

    Richardson, J Craig; Bowtell, Richard W; Mäder, Karsten; Melia, Colin D

    2005-06-15

    Magnetic resonance imaging (MRI) is a powerful imaging modality that provides internal images of materials and living organisms on a microscopic and macroscopic scale. It is non-invasive and non-destructive, and one of very few techniques that can observe internal events inside undisturbed specimens in situ. It is versatile, as a wide range of NMR modalities can be accessed, and 2D and 3D imaging can be undertaken. Despite widespread use and major advances in clinical MRI, it has seen limited application in the pharmaceutical sciences. In vitro studies have focussed on drug release mechanisms in polymeric delivery systems, but isolated studies of bioadhesion, tablet properties, and extrusion and mixing processes illustrate the wider potential. Perhaps the greatest potential however, lies in investigations of pharmaceuticals in vivo, where pilot human and animal studies have demonstrated we can obtain unique insights into the behaviour of gastrointestinal, topical, colloidal, and targeted drug delivery systems.

  9. Feasibility of using ultra-high field (7 T MRI for clinical surgical targeting.

    Directory of Open Access Journals (Sweden)

    Yuval Duchin

    Full Text Available The advantages of ultra-high magnetic field (7 Tesla MRI for basic science research and neuroscience applications have proven invaluable. Structural and functional MR images of the human brain acquired at 7 T exhibit rich information content with potential utility for clinical applications. However, (1 substantial increases in susceptibility artifacts, and (2 geometrical distortions at 7 T would be detrimental for stereotactic surgeries such as deep brain stimulation (DBS, which typically use 1.5 T images for surgical planning. Here, we explore whether these issues can be addressed, making feasible the use of 7 T MRI to guide surgical planning. Twelve patients with Parkinson's disease, candidates for DBS, were scanned on a standard clinical 1.5 T MRI and a 7 T MRI scanner. Qualitative and quantitative assessments of global and regional distortion were evaluated based on anatomical landmarks and transformation matrix values. Our analyses show that distances between identical landmarks on 1.5 T vs. 7 T, in the mid-brain region, were less than one voxel, indicating a successful co-registration between the 1.5 T and 7 T images under these specific imaging parameter sets. On regional analysis, the central part of the brain showed minimal distortion, while inferior and frontal areas exhibited larger distortion due to proximity to air-filled cavities. We conclude that 7 T MR images of the central brain regions have comparable distortions to that observed on a 1.5 T MRI, and that clinical applications targeting structures such as the STN, are feasible with information-rich 7 T imaging.

  10. Comparison of MRI findings with clinical symptoms in temporomandibular joint internal derangement

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Ki Jeong [Chonbuk National University College of Medicine, Gwangju (Korea, Republic of)

    2005-06-15

    To determine the clinical correlation of magnetic resonance imaging (MRI) findings of temporomandibular joint internal derangements. The MR images of 150 TMJs in 75 patients were analyzed. The clinical symptoms were pain in the pre auricular area and masticatory muscles and TMJ sounds. There was a statistically significant relationship between the MRI diagnoses of different types of disc displacements and clinical findings of pain, clicking, and crepitus. The risk of TMJ pain was increased when the disc displacement without reduction occurred at the same time in combination with the osteoarthrosis and effusion. Regardless of the results, the data indicate that each of these MR imaging variables may not be regarded as the unique and dominant factor in defining TMJ pain occurrence.

  11. Normal feline brain: clinical anatomy using magnetic resonance imaging.

    Science.gov (United States)

    Mogicato, G; Conchou, F; Layssol-Lamour, C; Raharison, F; Sautet, J

    2012-04-01

    The purpose of this study was to provide a clinical anatomy atlas of the feline brain using magnetic resonance imaging (MRI). Brains of twelve normal cats were imaged using a 1.5 T magnetic resonance unit and an inversion/recovery sequence (T1). Fourteen relevant MRI sections were chosen in transverse, dorsal, median and sagittal planes. Anatomic structures were identified and labelled using anatomical texts and Nomina Anatomica Veterinaria, sectioned specimen heads, and previously published articles. The MRI sections were stained according to the major embryological and anatomical subdivisions of the brain. The relevant anatomical structures seen on MRI will assist clinicians to better understand MR images and to relate this neuro-anatomy to clinical signs. © 2011 Blackwell Verlag GmbH.

  12. Functional MRI studies of human vision on a clinical imager

    International Nuclear Information System (INIS)

    George, J.S.; Lewine, J.D.; Aine, C.J.; van Hulsteyn, D.; Wood, C.C.; Sanders, J.; Maclin, E.; Belliveau, J.W.; Caprihan, A.

    1992-01-01

    During the past decade, Magnetic Resonance Imaging (MRI) has become the method of choice for imaging the anatomy of the human brain. Recently, Belliveau and colleagues have reported the use of echo planar magnetic resonance imaging (EPI) to image patterns of neural activity. Here, we report functional MR imaging in response to visual stimulation without the use of contrast agents, and without the extensive hardware modifications required for EPI. Regions of activity were observed near the expected locations of V1, V2 and possibly V3 and another active region was observed near the parietal-occipital sulcus on the superior surface of the cerebrum. These locations are consistent with sources observed in neuromagnetic studies of the human visual response

  13. Imaging of the myocardium using {sup 18}F-FDG-PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ferda, Jiří, E-mail: ferda@fnplzen.cz [Clinic of the Imaging Methods, University Hospital Plzen, Alej Svobody 80, 304 60 Plzeň (Czech Republic); Hromádka, Milan, E-mail: hromadkam@fnplzen.cz [Department of Cardiology, University Hospital Plzen, Alej Svobody 80, 304 60 Plzeň (Czech Republic); Baxa, Jan, E-mail: baxaj@fnplzen.cz [Clinic of the Imaging Methods, University Hospital Plzen, Alej Svobody 80, 304 60 Plzeň (Czech Republic)

    2016-10-15

    Highlights: • The natural combination of the metabolic and structural information is the most important strenghtof myocardial PET/MRI. • Metabolic conversion to glycolysis is needed in the assesment ov the viable myocardium. • Metabolic conversion to the fatty acid metabolism is the crucial in the assesment of the ischemic memory and myocardial inflammation. - Abstract: The introduction of the integrated hybrid PET/MRI equipment creates the possibility to perform PET and MRI simultaneously. Depending on the clinical question, the metabolic conversion to glycolytic activity or beta-oxidation is performed before the application of FDG. Since FDG aids to evaluate the energetic metabolism of the myocytes and myocardial MRI reaches the imaging capabilities of perfusion and tissue characterization in the daily routine, FDG-PET/MRI looks to be a promising method of PET/MRI exploitation in cardiac imaging. When myocardial FDG uptake should be evaluated in association with the perfusion distribution, the cross-evaluation of FDG accumulation distribution and perfusion distribution pattern is necessary. The different scenarios may be used in the assessment of myocardium, the conversion to glycolytic activity is used in the imaging of the viable myocardium, but the glycolytic activity suppression might be used in the indications of the identification of injured myocardium by ischemia or inflammation. FDG-PET/MRI might aid to answer the clinical tasks according to the structure, current function and possibilities to improve the function in ischemic heart disease or to display the extent or activity of myocardial inflammation in sarcoidosis. The tight coupling between metabolism, perfusion and contractile function offers an opportunity for the simultaneous assessment of cardiac performance using one imaging modality.

  14. Incidental ferumoxytol artifacts in clinical brain MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bowser, Bruce A.; Campeau, Norbert G.; Carr, Carrie M.; Diehn, Felix E.; McDonald, Jennifer S.; Miller, Gary M.; Kaufmann, Timothy J. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2016-11-15

    Ferumoxytol (Feraheme) is a parenteral therapy approved for treatment of iron deficiency anemia. The product insert for ferumoxytol states that it may affect the diagnostic ability of MRI for up to 3 months. However, the expected effects may not be commonly recognized among clinical neuroradiologists. Our purpose is to describe the artifacts we have seen at our institution during routine clinical practice. We reviewed the patients at our institution that had brain MRI performed within 90 days of receiving intravenous ferumoxytol. The imaging was reviewed for specific findings, including diffusion-weighted imaging vascular susceptibility artifact, gradient-echo echo-planar T2*-weighted vascular susceptibility artifact, SWI/SWAN vascular susceptibility artifact, hypointense vascular signal on T2-weighted images, pre-gadolinium contrast vascular enhancement on magnetization-prepared rapid acquisition gradient echo (MPRAGE) imaging, and effects on post-gadolinium contrast T1 imaging. Multiple artifacts were observed in patients having a brain MRI within 3 days of receiving intravenous ferumoxytol. These included susceptibility artifact on DWI, GRE, and SWAN/SWI imaging, pre-gadolinium contrast increased vascular signal on MPRAGE imaging, and decreased expected enhancement on post-gadolinium contrast T1-weighted imaging. Ferumoxytol can create imaging artifacts which complicate clinical interpretation when brain MRI is performed within 3 days of administration. Recognition of the constellation of artifacts produced by ferumoxytol is important in order to obviate additional unnecessary examinations and mitigate errors in interpretation. (orig.)

  15. Prospective comparison of T2w-MRI and dynamic-contrast-enhanced MRI, 3D-MR spectroscopic imaging or diffusion-weighted MRI in repeat TRUS-guided biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Portalez, Daniel [Clinique Pasteur, 45, Department of Radiology, Toulouse (France); Rollin, Gautier; Mouly, Patrick; Jonca, Frederic; Malavaud, Bernard [Hopital de Rangueil, Department of Urology, Toulouse Cedex 9 (France); Leandri, Pierre [Clinique Saint Jean, 20, Department of Urology, Toulouse (France); Elman, Benjamin [Clinique Pasteur, 45, Department of Urology, Toulouse (France)

    2010-12-15

    To compare T2-weighted MRI and functional MRI techniques in guiding repeat prostate biopsies. Sixty-eight patients with a history of negative biopsies, negative digital rectal examination and elevated PSA were imaged before repeat biopsies. Dichotomous criteria were used with visual validation of T2-weighted MRI, dynamic contrast-enhanced MRI and literature-derived cut-offs for 3D-spectroscopy MRI (choline-creatine-to-citrate ratio >0.86) and diffusion-weighted imaging (ADC x 10{sup 3} mm{sup 2}/s < 1.24). For each segment and MRI technique, results were rendered as being suspicious/non-suspicious for malignancy. Sextant biopsies, transition zone biopsies and at least two additional biopsies of suspicious areas were taken. In the peripheral zones, 105/408 segments and in the transition zones 19/136 segments were suspicious according to at least one MRI technique. A total of 28/68 (41.2%) patients were found to have cancer. Diffusion-weighted imaging exhibited the highest positive predictive value (0.52) compared with T2-weighted MRI (0.29), dynamic contrast-enhanced MRI (0.33) and 3D-spectroscopy MRI (0.25). Logistic regression showed the probability of cancer in a segment increasing 12-fold when T2-weighted and diffusion-weighted imaging MRI were both suspicious (63.4%) compared with both being non-suspicious (5.2%). The proposed system of analysis and reporting could prove clinically relevant in the decision whether to repeat targeted biopsies. (orig.)

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  17. Postoperative MRI evaluation of anorectal malformations with clinical correlation

    International Nuclear Information System (INIS)

    Fukuya, T.; Honda, H.; Kubota, M.; Hayashi, T.; Kawashima, A.; Tateshi, Y.; Shono, T.; Suita, S.; Masuda, K.

    1993-01-01

    Sixteen postoperative patients with anorectal malformation were evaluated by MRI, and the results compared with the clinical assessment. Patients were classified into three groups - good (group 1, n = 10), fair (group 2, n = 3) and poor (group 3, n = 3) - on the basis of Kelly's clinical score of incontinence. The degree of development of the puborectalis and external sphincter muscles and the levator hammock was evaluated on MRI in comparison with patients without anorectal disease. The proportions of fair or poor development of the muscles were 37% in group 1,22% in group 2 and 67% in group 3. Although fair or poor development of the muscles was seen more frequently in group 3, there was no statistically significant difference between groups. However, poorly developed muscles were seen only in patients with fair or poor clinical scores. The difference in the anorectal angle measured on sagittal MRI images between patients in group 1 and groups 2 or 3 was significant. Our study indicates that MRI evaluation based solely on muscle development can be misleading, and measurement of the anorectal angle should be included in the MRI evaluation. (orig.)

  18. The OMERACT rheumatoid arthritis magnetic resonance imaging (MRI) scoring system

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Peterfy, Charles G.; Bird, Paul

    2017-01-01

    Objective: The Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis (RA) Magnetic Resonance Imaging (MRI) scoring system (RAMRIS), evaluating bone erosion, bone marrow edema/osteitis, and synovitis, was introduced in 2002, and is now the standard method of objectively quantifying...... inflammation and damage by MRI in RA trials. The objective of this paper was to identify subsequent advances and based on them, to provide updated recommendations for the RAMRIS. Methods: MRI studies relevant for RAMRIS and technical and scientific advances were analyzed by the OMERACT MRI in Arthritis Working...... Group, which used these data to provide updated considerations on image acquisition, RAMRIS definitions, and scoring systems for the original and new RA pathologies. Further, a research agenda was outlined. Results: Since 2002, longitudinal studies and clinical trials have documented RAMRIS variables...

  19. Competitive advantage of PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Jadvar, Hossein, E-mail: jadvar@usc.edu; Colletti, Patrick M.

    2014-01-15

    Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved.

  20. Competitive advantage of PET/MRI.

    Science.gov (United States)

    Jadvar, Hossein; Colletti, Patrick M

    2014-01-01

    Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. Competitive advantage of PET/MRI

    International Nuclear Information System (INIS)

    Jadvar, Hossein; Colletti, Patrick M.

    2014-01-01

    Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved

  2. Clinical use of digital retrospective image fusion of CT, MRI, FDG-PET and SPECT - fields of indications and results; Klinischer Einsatz der digitalen retrospektiven Bildfusion von CT, MRT, FDG-PET und SPECT - Anwendungsgebiete und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Lemke, A.J.; Niehues, S.M.; Amthauer, H.; Felix, R. [Campus Virchow-Klinikum, Klinik fuer Strahlenheilkunde, Charite, Universitaetsmedizin Berlin (Germany); Rohlfing, T. [Dept. of Neurosurgery, Stanford Univ. (United States); Hosten, N. [Inst. fuer Diagnostische Radiologie, Ernst-Moritz-Arndt-Univ. Greifswald (Germany)

    2004-12-01

    Purpose: To evaluate the feasibility and the clinical benefits of retrospective digital image fusion (PET, SPECT, CT and MRI). Materials and methods: In a prospective study, a total of 273 image fusions were performed and evaluated. The underlying image acquisitions (CT, MRI, SPECT and PET) were performed in a way appropriate for the respective clinical question and anatomical region. Image fusion was executed with a software program developed during this study. The results of the image fusion procedure were evaluated in terms of technical feasibility, clinical objective, and therapeutic impact. Results: The most frequent combinations of modalities were CT/PET (n = 156) and MRI/PET (n = 59), followed by MRI/SPECT (n = 28), CT/SPECT (n = 22) and CT/MRI (n = 8). The clinical questions included following regions (more than one region per case possible): neurocranium (n = 42), neck (n = 13), lung and mediastinum (n = 24), abdomen (n = 181), and pelvis (n = 65). In 92.6% of all cases (n = 253), image fusion was technically successful. Image fusion was able to improve sensitivity and specificity of the single modality, or to add important diagnostic information. Image fusion was problematic in cases of different body positions between the two imaging modalities or different positions of mobile organs. In 37.9% of the cases, image fusion added clinically relevant information compared to the single modality. Conclusion: For clinical questions concerning liver, pancreas, rectum, neck, or neurocranium, image fusion is a reliable method suitable for routine clinical application. Organ motion still limits its feasibility and routine use in other areas (e.g., thorax). (orig.)

  3. MRI of the scrotum. Recommendations of the ESUR Scrotal and Penile Imaging Working Group

    International Nuclear Information System (INIS)

    Tsili, Athina C.; Ntorkou, Alexandra; Bertolotto, Michele; Turgut, Ahmet Tuncay; Dogra, Vikram; Freeman, Simon; Rocher, Laurence; Belfield, Jane; Studniarek, Michal; Derchi, Lorenzo E.; Oyen, Raymond; Ramchandani, Parvati; Secil, Mustafa; Richenberg, Jonathan

    2018-01-01

    The Scrotal and Penile Imaging Working Group (SPI-WG) appointed by the board of the European Society of Urogenital Radiology (ESUR) has produced recommendations for magnetic resonance imaging (MRI) of the scrotum. The SPI-WG searched for original and review articles published before September 2016 using the Pubmed and Medline databases. Keywords used were 'magnetic resonance imaging', 'testis or testicle or testicular', 'scrotum', 'intratesticular', 'paratesticular', 'extratesticular' 'diffusion-weighted', 'dynamic MRI'. Consensus was obtained among the members of the subcommittee. The expert panel proposed recommendations using Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence. The recommended MRI protocol should include T1-, T2-weighted imaging, diffusion-weighted imaging and dynamic contrast-enhanced MRI. Scrotal MRI can be clinically applied for lesion characterisation (primary), including both intratesticular and paratesticular masses, differentiation between germ-cell and non-germ-cell neoplasms (evolving), characterisation of the histological type of testicular germ cell neoplasms (TGCNs, in selected cases), local staging of TGCNs (primary), acute scrotum (in selected cases), trauma (in selected cases) and undescended testes (primary). The ESUR SPI-WG produced this consensus paper in which the existing literature on MRI of the scrotum is reviewed. The recommendations for the optimal imaging technique and clinical indications are presented. (orig.)

  4. MRI of the scrotum. Recommendations of the ESUR Scrotal and Penile Imaging Working Group

    Energy Technology Data Exchange (ETDEWEB)

    Tsili, Athina C.; Ntorkou, Alexandra [University of Ioannina, Department of Clinical Radiology, Medical School, Ioannina (Greece); Bertolotto, Michele [Uco di Radiologia, Trieste Univ. (Italy); Turgut, Ahmet Tuncay [Ankara Training and Research Hospital, Department of Radiology, Ankara (Turkey); Dogra, Vikram [University of Rochester School of Medicine and Dentistry, Department of Imaging Sciences, Rochester, NY (United States); Freeman, Simon [Plymouth Hospitals NHS Trust, Plymouth (United Kingdom); Rocher, Laurence [Hopitaux Universitaires Paris Sud, APHP, Ecole Doctorale Biosigne, Le Kremlin Bicetre (France); Belfield, Jane [Royal Liverpool University Hospital, Liverpool (United Kingdom); Studniarek, Michal [Medical University of Gdansk, Gdansk (Poland); Derchi, Lorenzo E. [Universita di Genova, Genova (Italy); Oyen, Raymond [KU Leuven, Radiology, Leuven (Belgium); Ramchandani, Parvati [Perelman School of Medicine of the University of Pennsylvania, Philadelphia, PA (United States); Secil, Mustafa [Dokuz Eylul University Faculty of Medicine, Department of Radiology, Izmir (Turkey); Richenberg, Jonathan [Royal Sussex County Hospital Brighton and Brighton and Sussex Medical School, Brighton, Sussex (United Kingdom)

    2018-01-15

    The Scrotal and Penile Imaging Working Group (SPI-WG) appointed by the board of the European Society of Urogenital Radiology (ESUR) has produced recommendations for magnetic resonance imaging (MRI) of the scrotum. The SPI-WG searched for original and review articles published before September 2016 using the Pubmed and Medline databases. Keywords used were 'magnetic resonance imaging', 'testis or testicle or testicular', 'scrotum', 'intratesticular', 'paratesticular', 'extratesticular' 'diffusion-weighted', 'dynamic MRI'. Consensus was obtained among the members of the subcommittee. The expert panel proposed recommendations using Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence. The recommended MRI protocol should include T1-, T2-weighted imaging, diffusion-weighted imaging and dynamic contrast-enhanced MRI. Scrotal MRI can be clinically applied for lesion characterisation (primary), including both intratesticular and paratesticular masses, differentiation between germ-cell and non-germ-cell neoplasms (evolving), characterisation of the histological type of testicular germ cell neoplasms (TGCNs, in selected cases), local staging of TGCNs (primary), acute scrotum (in selected cases), trauma (in selected cases) and undescended testes (primary). The ESUR SPI-WG produced this consensus paper in which the existing literature on MRI of the scrotum is reviewed. The recommendations for the optimal imaging technique and clinical indications are presented. (orig.)

  5. [Clinical use of interventional MR imaging].

    Science.gov (United States)

    Kahn, Thomas; Schulz, Thomas; Moche, Michael; Prothmann, Sascha; Schneider, Jens-Peter

    2003-01-01

    The integration of diagnostic and therapeutic procedures by MRI is based on the combination of excellent morphologic and functional imaging. The spectrum of MR-guided interventions includes biopsies, thermal ablation procedures, vascular applications, and intraoperative MRI. In all these applications, different scientific groups have obtained convincing results in basic developments as well as in clinical use. Interventional MRI (iMRI) is expected to attain an important role in interventional radiology, minimal invasive therapy, and monitoring of surgical procedures.

  6. Clinical evaluation of MRI for lumbar spinal disease

    International Nuclear Information System (INIS)

    Moriwaka, Yosuke; Nakayama, Sachiko; Murai, Nobuko; Watanabe, Katsushi; Kawano, Keiichiro; Tajima, Naoya; Kihara, Yasushi; Okada, Akihiko; Fujimoto, Toshiro.

    1985-01-01

    Thirty-two patients were examined to determine the clinical usefulness of magnetic resonance imaging (MRI) of the lumbar spine. MRI using a resistive magnet at 0.1 Tesla was compared with computed tomography (CT) and myelography. A saturation recovery (SR) technique with repetition time (TR) of 500 msec was used in all cases. There were 19 cases with disk herniation, 5 with canal stenosis, 2 with spondylosis deformans and 6 with other suspected disease. MRI showed the protrusion of disk, displacement of epidural fat and degenerative change of disk more clearly than CT and myelography. Of the 12 herniated disks, 8 disks were clearly shown and one was not detected by MRI. In some cases, herniated disk could not be differentiated from disk bulging. With further technical advance, MRI is likely to become the initial procedure for evaluation of lumbar spinal disease. (author)

  7. A correlation of clinical, MRI and brain SPECT in dementia

    International Nuclear Information System (INIS)

    Shelley, S.; Indirani, M.; Gokhale, S.; Anirudhan, N.; Sivakumar, M.R.; Jaganathan, K.

    2004-01-01

    Background: Dementia is a clinical syndrome characterised by acquired impairment in multiple neuropsycologic and behavior domains including memory, language, speech, visuospatial ability, cognition and mood/personality. Dementia produces deficits in perfusion reflecting decreased metabolic needs. Neuroimaging techniques help in determining whether the cognitive symptoms are organic and in which pattern of cognitive loss the patient may evolve. AIM: To differentiate various types of Dementia, based on the regional perfusion abnormalities seen in Brain SPECT and correlate this with Clinical and MRI findings. Material and methods: Patients suffering from memory impairment and memory loss were referred to our department for Brain SPECT as a part of work up for Dementia. They had undergone a detailed clinical examination, psychometry, mini mental status examination (MMSE), memory/cognitive testing and an MRI. Brain SPECT was done after injecting Tc 99m ECD (Ethylene Cysteinate Dimer ) and imaging after 45 minutes. The images obtained were reconstructed in a conventional way. The various patterns of perfusion abnormalities seen in the SPECT images was studied and correlated with MRI and clinical findings. The patients were thus classified as having Multi Infarct Dementia, Alzheimer's disease, Fronto-Temporal Dementia and Mixed variety. Results: Twenty One Patients were included in our study from February 2003 to February 2004. The mean age of the patients was 73 years ( 37 to 81). 15 were males and 6 were females. Out of 21 patients, 12 had Multi Infarct Dementia, 4 had Alzheimer's disease, 1 had Fronto- Temporal Dementia and 4 had Mixed variety. Conclusion: Brain SPECT aids in substantiating the clinical findings and in correlation with MRI helps in distinguishing various types of Dementia and thus has prognostic implications and helps in instituting early appropriate treatment to the patient. In our study, the majority of the patients have Multi Infarct Dementia

  8. Image fusion of MRI and fMRI with intraoperative MRI data: methods and clinical relevance for neurosurgical interventions; Fusion von MRT-, fMRT- und intraoperativen MRT-Daten. Methode und klinische Bedeutung am Beispiel neurochirurgischer Interventionen

    Energy Technology Data Exchange (ETDEWEB)

    Moche, M.; Busse, H.; Dannenberg, C.; Schulz, T.; Schmidt, F.; Kahn, T. [Universitaetsklinikum Leipzig (Germany). Klinik und Poliklinik fuer Diagnostische Radiologie; Schmitgen, A. [GMD Forschungszentrum Informationstechnik GmbH-FIT, Sankt Augustin (Germany); Trantakis, C.; Winkler, D. [Klinik und Poliklinik fuer Neurochirurgie, Universitaetsklinikum Leipzig (Germany)

    2001-11-01

    The aim of this work was to realize and clinically evaluate an image fusion platform for the integration of preoperative MRI and fMRI data into the intraoperative images of an interventional MRI system with a focus on neurosurgical procedures. A vertically open 0.5 T MRI scanner was equipped with a dedicated navigation system enabling the registration of additional imaging modalities (MRI, fMRI, CT) with the intraoperatively acquired data sets. These merged image data served as the basis for interventional planning and multimodal navigation. So far, the system has been used in 70 neurosurgical interventions (13 of which involved image data fusion - requiring 15 minutes extra time). The augmented navigation system is characterized by a higher frame rate and a higher image quality as compared to the system-integrated navigation based on continuously acquired (near) real time images. Patient movement and tissue shifts can be immediately detected by monitoring the morphological differences between both navigation scenes. The multimodal image fusion allowed a refined navigation planning especially for the resection of deeply seated brain lesions or pathologies close to eloquent areas. Augmented intraoperative orientation and instrument guidance improve the safety and accuracy of neurosurgical interventions. (orig.) [German] Ziel dieser Arbeit waren die Realisierung und klinische Bewertung einer Bildfusion praeoperativer MRT- und fMRT-Bilder mit intraoperativen Datensaetzen eines interventionellen MRT-Systems am Beispiel neurochirurgischer Eingriffe. Ein vertikal offenes 0,5-T-MRT-System wurde mit einem erweiterten Navigationssystem ausgestattet, welches eine Integration zusaetzlicher Bildinformationen (Hochfeld-MRT, fMRT, CT) in die intraoperativ akquirierten Datensaetze erlaubt. Diese fusionierten Bilddaten wurden zur Interventionsplanung und multimodalen Navigation verwendet. Bisher wurde das System bei insgesamt 70 neurochirurgischen Eingriffen eingesetzt, davon 13

  9. Clinical potential and limitation of MRI for degenerative lumbar spinal diseases. Comparison of MRI, myelography, CT and selective nerve root infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Seki, Michihiro; Kikuchi, Shinichi [Fukushima Medical Coll. (Japan)

    1994-12-01

    To assess the clinical potential and limitations of magnetic resonance imaging (MRI) in degenerative lumbar spinal diseases, the findings of MR imaging were compared with those of myelography and CT. The subjects were 80 patients with intervertebral disc herniation (46), spondylosis (28), degenerative spondylolisthesis (5), and spondylolysis (one). There was a good correlation between sagittal MRI (T1-weighted images) and myelography in measuring the anteroposterior diameter and the compression rate of the injured dural canal in all disease categories. However, MRI was inferior, irrespective of sagittal and coronal images, to myelography in detecting blocking of the dural canal and intradural findings such as redundant nerve roots. MRI was inferior to selective nerve root infiltration in visualizing the compression of the nerve root, irrespective of diseases; however, there was no difference in abnormal findings of the running of nerve root between the two modalities. Transverse MRI was superior to CT in visualizing the nerve root. Thus, MRI alone is insufficient for the diagnosis of degenerative lumbar spinal diseases, and the other modalities should be supplementary for pathophysiological understanding of these diseases. (N.K.).

  10. Clinical potential and limitation of MRI for degenerative lumbar spinal diseases. Comparison of MRI, myelography, CT and selective nerve root infiltration

    International Nuclear Information System (INIS)

    Seki, Michihiro; Kikuchi, Shinichi

    1994-01-01

    To assess the clinical potential and limitations of magnetic resonance imaging (MRI) in degenerative lumbar spinal diseases, the findings of MR imaging were compared with those of myelography and CT. The subjects were 80 patients with intervertebral disc herniation (46), spondylosis (28), degenerative spondylolisthesis (5), and spondylolysis (one). There was a good correlation between sagittal MRI (T1-weighted images) and myelography in measuring the anteroposterior diameter and the compression rate of the injured dural canal in all disease categories. However, MRI was inferior, irrespective of sagittal and coronal images, to myelography in detecting blocking of the dural canal and intradural findings such as redundant nerve roots. MRI was inferior to selective nerve root infiltration in visualizing the compression of the nerve root, irrespective of diseases; however, there was no difference in abnormal findings of the running of nerve root between the two modalities. Transverse MRI was superior to CT in visualizing the nerve root. Thus, MRI alone is insufficient for the diagnosis of degenerative lumbar spinal diseases, and the other modalities should be supplementary for pathophysiological understanding of these diseases. (N.K.)

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... can also provide functional information (fMRI) in selected cases. MR images of the brain and other cranial structures are clearer and more detailed than with other imaging methods. This detail makes MRI an invaluable tool in early diagnosis and evaluation of many conditions, ...

  12. First patients treated with a 1.5 T MRI-Linac: clinical proof of concept of a high-precision, high-field MRI guided radiotherapy treatment

    Science.gov (United States)

    Raaymakers, B. W.; Jürgenliemk-Schulz, I. M.; Bol, G. H.; Glitzner, M.; Kotte, A. N. T. J.; van Asselen, B.; de Boer, J. C. J.; Bluemink, J. J.; Hackett, S. L.; Moerland, M. A.; Woodings, S. J.; Wolthaus, J. W. H.; van Zijp, H. M.; Philippens, M. E. P.; Tijssen, R.; Kok, J. G. M.; de Groot-van Breugel, E. N.; Kiekebosch, I.; Meijers, L. T. C.; Nomden, C. N.; Sikkes, G. G.; Doornaert, P. A. H.; Eppinga, W. S. C.; Kasperts, N.; Kerkmeijer, L. G. W.; Tersteeg, J. H. A.; Brown, K. J.; Pais, B.; Woodhead, P.; Lagendijk, J. J. W.

    2017-12-01

    The integration of 1.5 T MRI functionality with a radiotherapy linear accelerator (linac) has been pursued since 1999 by the UMC Utrecht in close collaboration with Elekta and Philips. The idea behind this integrated device is to offer unrivalled, online and real-time, soft-tissue visualization of the tumour and the surroundings for more precise radiation delivery. The proof of concept of this device was given in 2009 by demonstrating simultaneous irradiation and MR imaging on phantoms, since then the device has been further developed and commercialized by Elekta. The aim of this work is to demonstrate the clinical feasibility of online, high-precision, high-field MRI guidance of radiotherapy using the first clinical prototype MRI-Linac. Four patients with lumbar spine bone metastases were treated with a 3 or 5 beam step-and-shoot IMRT plan. The IMRT plan was created while the patient was on the treatment table and based on the online 1.5 T MR images; pre-treatment CT was deformably registered to the online MRI to obtain Hounsfield values. Bone metastases were chosen as the first site as these tumors can be clearly visualized on MRI and the surrounding spine bone can be detected on the integrated portal imager. This way the portal images served as an independent verification of the MRI based guidance to quantify the geometric precision of radiation delivery. Dosimetric accuracy was assessed post-treatment from phantom measurements with an ionization chamber and film. Absolute doses were found to be highly accurate, with deviations ranging from 0.0% to 1.7% in the isocenter. The geometrical, MRI based targeting as confirmed using portal images was better than 0.5 mm, ranging from 0.2 mm to 0.4 mm. In conclusion, high precision, high-field, 1.5 T MRI guided radiotherapy is clinically feasible.

  13. Clinical application of functional MRI

    International Nuclear Information System (INIS)

    Taniwaki, Takayuki

    2010-01-01

    Described is the present state of clinical application of fMRI in the preoperative assessment of brain tumors, and plasticity in and pathophysiology of central diseases. For the tumor resection, fMRI is useful for risk assessment of postoperative nerve dysfunction, for selection of the patient rather suitable for brain mapping at the invasive surgery than at the pre-operation and for guidance of the operation itself. Preoperative fMRI alone can neither distinguish the regions of the primary and secondary functions nor exhibit the relation between the tumor and white matter fibers but there are compensatory means for these drawbacks. Benefit of preoperative fMRI has not yet been based on the evidence on double blind trials. Combination of fMRI imaging and electroencephalography (EEG) finding has shown that, in generalized epilepsy, extensive and stimulated activation occurs in both frontal/occipital regions and in thalamus area, respectively, and that the concomitant lowered activities are conceivably the reflection of burst discharge in normal brain functions. Plasticity in the human brain has been demonstrated by fMRI in cerebral vascular diseases, multiple sclerosis and amyotrophic lateral sclerosis. Pathogenesis of Parkinson disease and depression has been better understood by fMRI investigations revealing regions with elevated and reduced activities. Studies of attention deficit hyperactivity disorder have shown similar change of activities with functional reductions of the right dorsolateral frontal anterior area and of dorsal frontal cingulate gyrus, together with stimulated wider regions to given tasks. As above, fMRI has greatly contributed to our understanding of diseases of central nervous system and is to be expected to expand wider in this field. (T.T.)

  14. An MRI system for imaging neonates in the NICU: initial feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Tkach, Jean A.; Loew, Wolfgang; Pratt, Ron G.; Daniels, Barret R.; Giaquinto, Randy O.; Winter, Patrick M.; Li, Yu; Dumoulin, Charles L. [Cincinnati Children' s Hospital Medical Center, Imaging Research Center, Department of Radiology, Cincinnati, OH (United States); Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Hillman, Noah H.; Jobe, Alan H.; Kallapur, Suhas G.; Merhar, Stephanie L.; Ikegami, Machiko; Whitsett, Jeffrey A. [Perinatal Institute, Cincinnati Children' s Hospital Medical Center, Division of Neonatology and Pulmonary Biology, Cincinnati, OH (United States); Kline-Fath, Beth M. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2012-11-15

    Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate. (orig.)

  15. An MRI system for imaging neonates in the NICU: initial feasibility study

    International Nuclear Information System (INIS)

    Tkach, Jean A.; Loew, Wolfgang; Pratt, Ron G.; Daniels, Barret R.; Giaquinto, Randy O.; Winter, Patrick M.; Li, Yu; Dumoulin, Charles L.; Hillman, Noah H.; Jobe, Alan H.; Kallapur, Suhas G.; Merhar, Stephanie L.; Ikegami, Machiko; Whitsett, Jeffrey A.; Kline-Fath, Beth M.

    2012-01-01

    Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate. (orig.)

  16. An MRI system for imaging neonates in the NICU: initial feasibility study.

    Science.gov (United States)

    Tkach, Jean A; Hillman, Noah H; Jobe, Alan H; Loew, Wolfgang; Pratt, Ron G; Daniels, Barret R; Kallapur, Suhas G; Kline-Fath, Beth M; Merhar, Stephanie L; Giaquinto, Randy O; Winter, Patrick M; Li, Yu; Ikegami, Machiko; Whitsett, Jeffrey A; Dumoulin, Charles L

    2012-11-01

    Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate.

  17. Whole body MRI, including diffusion-weighted imaging in follow-up of patients with testicular cancer.

    Science.gov (United States)

    Mosavi, Firas; Laurell, Anna; Ahlström, Håkan

    2015-11-01

    Whole body (WB) magnetic resonance imaging (MRI), including diffusion-weighted imaging (DWI) has become increasingly utilized in cancer imaging, yet the clinical utility of these techniques in follow-up of testicular cancer patients has not been evaluated. The purpose of this study was to evaluate the feasibility of WB MRI with continuous table movement (CTM) technique, including multistep DWI in follow-up of patients with testicular cancer. WB MRI including DWI was performed in follow-up of 71 consecutive patients (median age, 37 years; range 19-84) with histologically confirmed testicular cancer. WB MRI protocol included axial T1-Dixon and T2-BLADE sequences using CTM technique. Furthermore, multi-step DWI was performed using b-value 50 and 1000 s/mm(2). One criterion for feasibility was patient tolerance and satisfactory image quality. Another criterion was the accuracy in detection of any pathological mass, compared to standard of reference. Signal intensity in DWI was used for evaluation of residual mass activity. Clinical, laboratory and imaging follow-up were applied as standard of reference for the evaluation of WB MRI. WB MRI was tolerated in nearly all patients (69/71 patients, 97%) and the image quality was satisfactory. Metal artifacts deteriorated the image quality in six patients, but it did not influence the overall results. No case of clinical relapse was observed during the follow-up time. There was a good agreement between conventional WB MRI and standard of reference in all patients. Three patients showed residual masses and DWI signal was not restricted in these patients. Furthermore, DWI showed abnormally high signal intensity in a normal-sized retroperitoneal lymph node indicating metastasis. The subsequent (18)F-FDG PET/CT could verify the finding. WB MRI with CTM technique including multi-step DWI is feasible in follow-up of patients with testicular cancer. DWI may contribute to important added-value data to conventional MRI sequences

  18. Clinical Evaluation of PET Image Quality as a Function of Acquisition Time in a New TOF-PET/MRI Compared to TOF-PET/CT--Initial Results.

    Science.gov (United States)

    Zeimpekis, Konstantinos G; Barbosa, Felipe; Hüllner, Martin; ter Voert, Edwin; Davison, Helen; Veit-Haibach, Patrick; Delso, Gaspar

    2015-10-01

    The purpose of this study was to compare only the performance of the PET component between a TOF-PET/CT (henceforth noted as PET/CT) scanner and an integrated TOF-PET/MRI (henceforth noted as PET/MRI) scanner concerning image quality parameters and quantification in terms of standardized uptake value (SUV) as a function of acquisition time (a surrogate of dose). The CT and MR image quality were not assessed, and that is beyond the scope of this study. Five brain and five whole-body patients were included in the study. The PET/CT scan was used as a reference and the PET/MRI acquisition time was consecutively adjusted, taking into account the decay between the scans in order to expose both systems to the same amount of the emitted signal. The acquisition times were then retrospectively reduced to assess the performance of the PET/MRI for lower count rates. Image quality, image sharpness, artifacts, and noise were evaluated. SUV measurements were taken in the liver and in the white matter to compare quantification. Quantitative evaluation showed strong correlation between PET/CT and PET/MRI brain SUVs. Liver correlation was good, however, with lower uptake estimation in PET/MRI, partially justified by bio-redistribution. The clinical evaluation showed that PET/MRI offers higher image quality and sharpness with lower levels of noise and artifacts compared to PET/CT with reduced acquisition times for whole-body scans while for brain scans there is no significant difference. The TOF-PET/MRI showed higher image quality compared to TOF-PET/CT as tested with reduced imaging times. However, this result accounts mainly for body imaging, while no significant differences were found in brain imaging.

  19. Fast ℓ1-SPIRiT Compressed Sensing Parallel Imaging MRI: Scalable Parallel Implementation and Clinically Feasible Runtime

    Science.gov (United States)

    Murphy, Mark; Alley, Marcus; Demmel, James; Keutzer, Kurt; Vasanawala, Shreyas; Lustig, Michael

    2012-01-01

    We present ℓ1-SPIRiT, a simple algorithm for auto calibrating parallel imaging (acPI) and compressed sensing (CS) that permits an efficient implementation with clinically-feasible runtimes. We propose a CS objective function that minimizes cross-channel joint sparsity in the Wavelet domain. Our reconstruction minimizes this objective via iterative soft-thresholding, and integrates naturally with iterative Self-Consistent Parallel Imaging (SPIRiT). Like many iterative MRI reconstructions, ℓ1-SPIRiT’s image quality comes at a high computational cost. Excessively long runtimes are a barrier to the clinical use of any reconstruction approach, and thus we discuss our approach to efficiently parallelizing ℓ1-SPIRiT and to achieving clinically-feasible runtimes. We present parallelizations of ℓ1-SPIRiT for both multi-GPU systems and multi-core CPUs, and discuss the software optimization and parallelization decisions made in our implementation. The performance of these alternatives depends on the processor architecture, the size of the image matrix, and the number of parallel imaging channels. Fundamentally, achieving fast runtime requires the correct trade-off between cache usage and parallelization overheads. We demonstrate image quality via a case from our clinical experimentation, using a custom 3DFT Spoiled Gradient Echo (SPGR) sequence with up to 8× acceleration via poisson-disc undersampling in the two phase-encoded directions. PMID:22345529

  20. Resolution improvement of brain PET images using prior information from MRI: clinical application on refractory epilepsy

    International Nuclear Information System (INIS)

    Silva-Rodríguez, Jesus; Tsoumpas, Charalampos; Aguiar, Pablo; Cortes, Julia; Urdaneta, Jesus Lopez

    2015-01-01

    An important counterpart of clinical Positron Emission Tomography (PET) for early diagnosis of neurological diseases is its low resolution. This is particularly important when evaluating diseases related to small hypometabolisms such as epilepsy. The last years, new hybrid systems combining PET with Magnetic Resonance (MR) has been increasingly used for several different clinical applications. One of the advantages of MR is the production of high spatial resolution images and a potential application of PET-MR imaging is the improvement of PET resolution using MR information. A potential advantage of resolution recovery of PET images is the enhancement of contrast delivering at the same time better detectability of small lesions or hypometabolic areas and more accurate quantification over these areas. Recently, Shidahara et al (2009) proposed a new method using wavelet transforms in order to produce PET images with higher resolution. We optimised Shidahara’s method (SFS-RR) to take into account possible shortcomings on the particular clinical datasets, and applied it to a group of patients diagnosed with refractory epilepsy. FDG-PET and MRI images were acquired sequentially and then co-registered using software tools. A complete evaluation of the PET/MR images was performed before and after the correction, including different parameters related with PET quantification, such as atlas-based metabolism asymmetry coefficients and Statistical Parametric Mapping results comparing to a database of 87 healthy subjects. Furthermore, an experienced physician analyzed the results of non-corrected and corrected images in order to evaluate improvements of detectability on a visual inspection. Clinical outcome was used as a gold standard. SFS-RR demonstrated to have a positive impact on clinical diagnosis of small hypometabolisms. New lesions were detected providing additional clinically relevant information on the visual inspection. SPM sensitivity for the detection of small

  1. Resolution improvement of brain PET images using prior information from MRI: clinical application on refractory epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Silva-Rodríguez, Jesus [Instituto de Investigaciones Sanitarias (IDIS), Santiago de Compostela (Spain); Tsoumpas, Charalampos [University of Leeds, Leeds (United Kingdom); Aguiar, Pablo; Cortes, Julia [Nuclear Medicine Department, University Hospital (CHUS), Santiago de Compostela (Spain); Urdaneta, Jesus Lopez [Instituto de Investigaciones Sanitarias (IDIS), Santiago de Compostela (Spain)

    2015-05-18

    An important counterpart of clinical Positron Emission Tomography (PET) for early diagnosis of neurological diseases is its low resolution. This is particularly important when evaluating diseases related to small hypometabolisms such as epilepsy. The last years, new hybrid systems combining PET with Magnetic Resonance (MR) has been increasingly used for several different clinical applications. One of the advantages of MR is the production of high spatial resolution images and a potential application of PET-MR imaging is the improvement of PET resolution using MR information. A potential advantage of resolution recovery of PET images is the enhancement of contrast delivering at the same time better detectability of small lesions or hypometabolic areas and more accurate quantification over these areas. Recently, Shidahara et al (2009) proposed a new method using wavelet transforms in order to produce PET images with higher resolution. We optimised Shidahara’s method (SFS-RR) to take into account possible shortcomings on the particular clinical datasets, and applied it to a group of patients diagnosed with refractory epilepsy. FDG-PET and MRI images were acquired sequentially and then co-registered using software tools. A complete evaluation of the PET/MR images was performed before and after the correction, including different parameters related with PET quantification, such as atlas-based metabolism asymmetry coefficients and Statistical Parametric Mapping results comparing to a database of 87 healthy subjects. Furthermore, an experienced physician analyzed the results of non-corrected and corrected images in order to evaluate improvements of detectability on a visual inspection. Clinical outcome was used as a gold standard. SFS-RR demonstrated to have a positive impact on clinical diagnosis of small hypometabolisms. New lesions were detected providing additional clinically relevant information on the visual inspection. SPM sensitivity for the detection of small

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... or patients with claustrophobia. Other MRI machines are open on the sides (open MRI). Open units are especially helpful for examining larger patients or those with claustrophobia. Newer open MRI units provide very high quality images for ...

  3. Multiparametric MRI in men with clinical suspicion of prostate cancer undergoing repeat biopsy

    DEFF Research Database (Denmark)

    Boesen, Lars; Nørgaard, Nis; Løgager, Vibeke

    2018-01-01

    Background Multiparametric magnetic resonance imaging (mpMRI) can improve detection of clinically significant prostate cancer (csPCa). Purpose To compare mpMRI score subgroups to systematic transrectal ultrasound-guided biopsies (TRUSbx) and prostate-specific antigen (PSA)-based findings...

  4. Multiparametric prostate MRI: technical conduct, standardized report and clinical use.

    Science.gov (United States)

    Manfredi, Matteo; Mele, Fabrizio; Garrou, Diletta; Walz, Jochen; Fütterer, Jurgen J; Russo, Filippo; Vassallo, Lorenzo; Villers, Arnauld; Emberton, Mark; Valerio, Massimo

    2018-02-01

    Multiparametric prostate MRI (mp-MRI) is an emerging imaging modality for diagnosis, characterization, staging, and treatment planning of prostate cancer (PCa). The technique, results reporting, and its role in clinical practice have been the subject of significant development over the last decade. Although mp-MRI is not yet routinely used in the diagnostic pathway, almost all urological guidelines have emphasized the potential role of mp-MRI in several aspects of PCa management. Moreover, new MRI sequences and scanning techniques are currently under evaluation to improve the diagnostic accuracy of mp-MRI. This review presents an overview of mp-MRI, summarizing the technical applications, the standardized reporting systems used, and their current roles in various stages of PCa management. Finally, this critical review also reports the main limitations and future perspectives of the technique.

  5. MRI quality control: six imagers studied using eleven unified image quality parameters

    International Nuclear Information System (INIS)

    Ihalainen, T.; Sipilae, O.; Savolainen, S.

    2004-01-01

    Quality control of the magnetic resonance imagers of different vendors in the clinical environment is non-harmonised, and comparing the performance is difficult. The purpose of this study was to develop and apply a harmonised long-term quality control protocol for the six imagers in our organisation in order to assure that they fulfil the same basic image quality requirements. The same Eurospin phantom set and identical imaging parameters were used with each imager. Values of 11 comparable parameters describing the image quality were measured. Automatic image analysis software was developed to objectively analyse the images. The results proved that the imagers were operating at a performance level adequate for clinical imaging. Some deficiencies were detected in image uniformity and geometry. The automated analysis of the Eurospin phantom images was successful. The measurements were successfully repeated after 2 weeks on one imager and after half a year on all imagers. As an objective way of examining the image quality, this kind of comparable and objective quality control of different imagers is considered as an essential step towards harmonisation of the clinical MRI studies through a large hospital organisation. (orig.)

  6. What are the differentiating clinical and MRI-features of enchondromas from low-grade chondrosarcomas?

    Energy Technology Data Exchange (ETDEWEB)

    Douis, Hassan [Royal Orthopaedic Hospital, Department of Radiology, Birmingham (United Kingdom); University Hospital Birmingham, Department of Radiology, Birmingham (United Kingdom); Parry, M. [Royal Orthopaedic Hospital, Department of Orthopaedic Oncology, Birmingham (United Kingdom); Vaiyapuri, S. [Royal Orthopaedic Hospital, Department of Musculoskeletal Pathology, Birmingham (United Kingdom); Davies, A.M. [Royal Orthopaedic Hospital, Department of Radiology, Birmingham (United Kingdom)

    2018-01-15

    To evaluate the role of clinical assessment, conventional and dynamic contrast-enhanced MRI in differentiating enchondromas from chondrosarcomas of long bone. The following clinical and MRI findings were assessed: age, gender, pain, pain attributable to lesion, tumour location, tumour length, presence, depth of endosteal scalloping, bone marrow oedema, soft tissue oedema, cortical destruction, periosteal reaction, bone expansion, macroscopic fat, calcification, soft tissue mass, haemorrhage, dynamic contrast-enhanced MRI. Clinical and MRI findings were compared with histopathological grading. Sixty patients with central chondroid tumours were included (27 enchondromas, 10 cartilaginous lesions of unknown malignant potential, 15 grade 1 chondrosarcomas, 8 high-grade chondrosarcomas). Pain attributed to lesion, tumour length, endosteal scalloping > 2/3, cortical destruction, bone expansion and soft tissue mass were differentiating features between enchondromas and grade 1 chondrosarcomas. Dynamic contrast-enhanced MRI could not differentiate enchondromas from grade 1 chondrosarcomas. Previously reported imaging signs of chondrosarcomas are useful in the diagnosis of grade 1 lesions but have lower sensitivity than in higher grade lesions. Deep endosteal scalloping is the most sensitive imaging sign of grade 1 chondrosarcomas. Pain due to the lesion is an important clinical sign of grade 1 chondrosarcomas. Dynamic contrast-enhanced MRI is not useful in differentiating enchondromas from grade 1 chondrosarcomas. (orig.)

  7. Brain lesions in neurofibromatosis: clinical and MRI findings

    International Nuclear Information System (INIS)

    Magnaldi, S.

    1990-01-01

    Neurofibromatosis is the commonest neuroectodermal disease. It is characterized by dysplasias and/or tumors of organs and tissues derived from the embryonic ectoderm, and most frequently presents with nervous system and cutaneous lesions. It can be classified as neurofibromatosis type 2 (NF-2 or bilateral acoustic neurofibromatosis). In order to assess clinical presentation of the disease and diagnostic value of Magnetic Resonance Imaging (MRI), the authors retrospectively evaluated the clinical records and the cranial MR studies of 21 patients with neurofibromatosis (18 with NF-1 and 3 with NF-2). Distinctive abnormalities between the two types were found in both clinical presentation and MR studies. Clinically, NF-1 patients presented most often with blindness, while NF-2 patients were deaf and had fewer cutaneous lesions. The evaluation of MR studies showed that NF-1 patients were more likely to be affected with intracranial gliomas, predominantly of the optic pathways. Moreover, foci of prolonged T2 relaxation were frequently observed, primarily in the globus pallidus of the basal ganglia and in the dentate nucleus of the cerebellum. Some of the foci in the globi pallidi exhibited increased signal intensity on T1-weighted images as well. NF-2 patients more frequently presented with bilateral acoustic schwannomas, meningiomas and cerebral white matter foci of prolonged T2 relaxation, but they did not have dentate and basal ganglia lesions. The authors conclude that as a rule the manifestations of NF-1 and NF-2 on cranial MRI are separate and distinct; they do not overlap. MRI is an useful clinical tool for the diagnosis and the follow-up of patients with neurofibromatosis

  8. Clinical magnetic resonance: imaging and spectroscopy

    International Nuclear Information System (INIS)

    Andrew, E.R.; Bydder, Graeme; Griffiths, John; Iles, Richard; Styles, Peter

    1990-01-01

    This book begins with a readable, comprehensive but non-mathematical introduction to the basic underlying principles of magnetic resonance. Further chapters include information on the theory and principles of MRI and MRS, the interpretation of MR images, the clinical applications and scope of MRI and MRS, practical aspects of spectroscopy and magnetic resonance, and also the practical problems associated with the siting, safety and operation of large MRI and MRS equipment. (author)

  9. Clinical evaluation of cardiovascular disease by gated-MRI (magnetic resonance imaging) in the operating field of 0.35 and 1.5 Tesla

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Naito, Hiroaki; Yamada, Yukinori; Kozuka, Takahiro

    1985-01-01

    To evaluate the clinical usefulness of magnetic resonance imaging (MRI) in the cardiovascular disease, 21 patients were examined using 0.35 and 1.5 Tesla superconductive type (Magnetom, Siemens). In our study, all patients were performed using ECG-gated MRI. Therefore, the cardiac chambers were discriminated clearly from the myocardial wall compared to non-gated MRI. Gated-MRI was performed in 6 normal persons in the operating field at 0.35 and 1.5 Tesla. The image of the latter showed superior than that of the former because of high S/N ratio. In myocardial infarction, infarct area was demonstrated as the wall thinning in 4 of 5 patients. Hypertrophic cardiomyopathy showed thickened left ventricle associated with its narrowed cavity in 7 patients. In the remaining such as congenital and valvular heart disease, global and regional cardiac morphology were assessed noninvasively by gated MRI. In addition, gated MRI was also applied to the diagnosis of peripheral vascular diseases. In dissecting aneurysm, double channels with an intimal flap in the aorta were clearly visualized. And in the aortitis syndrome, aortic dilatation and stenosis were also assessed noninvasively. In conclusion, gated MRI in diagnosing various abnormalities of cardiovascular disease was confirmed. (author)

  10. Imaging technique and current status of valvular heart disease using cardiac MRI

    International Nuclear Information System (INIS)

    Lotz, J.; Sohns, J.M.

    2013-01-01

    The main indications for cardiac magnetic resonance imaging (MRI) in the evaluation of valvular heart disease are pathologies of the aortic and pulmonary valve. For mitral and tricuspid valve pathologies MRI is not the first line modality as these are usually well visualized by echocardiography. The advantages of MRI in valvular heart disease are a high reliability in the evaluation of ventricular volumes and function as well as the assessment of the perivalvular arterial or atrial structures. This reliability and the limitless access to any imaging plane partially compensates for the lower temporal and spatial resolution in comparison to echocardiography. In patients with congenital heart disease, cardiac MRI is established as a valuable diagnostic tool in daily clinical management, especially for the evaluation of pulmonary valve defects. Nevertheless, echocardiography remains the first-line diagnostic imaging tool for the foreseeable future. (orig.) [de

  11. Use of dynamic images in radiology education: Movies of CT and MRI in the anatomy classroom.

    Science.gov (United States)

    Jang, Hye Won; Oh, Chang-Seok; Choe, Yeon Hyeon; Jang, Dong Su

    2018-04-19

    Radiology education is a key component in many preclinical anatomy courses. However, the reported effectiveness of radiology education within such anatomy classrooms has varied. This study was conducted to determine if a novel educational method using dynamic images of movies of computed tomography (CT) and magnetic resonance imaging (MRI) was effective in radiology education during a preclinical anatomy course, aided by clay modeling, specific hand gestures (digit anatomy), and reports from dissection findings uploaded to the anatomy course website (digital reports). Feedback surveys using a five-point Likert scale were administered to better clarify students' opinions regarding their understanding of CT and MRI of anatomical structures, as well as to determine if such preclinical radiology education was helpful in their clinical studies. After completion of the anatomy course taught with dynamic images of CT and MRI, most students demonstrated an adequate understanding of basic CT and MR images. Additionally, students in later clinical years generally believed that their study of radiologic images during the preclinical anatomy course was helpful for their clinical studies and clerkship rotations. Moreover, student scores on imaging anatomy examinations demonstrated meaningful improvements in performance after using dynamic images from movies of CT and MRI. Anat Sci Educ. © 2018 American Association of Anatomists. © 2018 American Association of Anatomists.

  12. MRI Primer

    International Nuclear Information System (INIS)

    Oldendorf, W.; Oldendorf, W. Jr.

    1991-01-01

    Designed for studies, radiologists, and clinicians at all levels of training, this book provides a basic introduction to the principles, physics, and instrumentation of magnetic resonance imaging. The fundamental concepts that are essential for the optimal clinical use of MRI are thoroughly explained in easily accessible terms. To facilitate the reader's comprehension, the material is presented nonmathematically, using no equations and a minimum of symbols and abbreviations. MRI Primer presents a clear account of the phenomenon of nuclear magnetic resonance and the use of gradient magnetic fields to create clinically useful images of cross-sectional slices. Close attention is given to the magnetization vector as a means of expressing nuclear behavior, the role of T 1 and T 2 weighing in imaging, the use of contrast agents, and the pulse sequences most often used in clinical practice, as well as to the relative capabilities and limitations of MRI and CT. The basic hardware components of an MRI scanner are described in detail. Sample MRI scans illustrate how MRI characterizes tissue. An appendix provides a brief introduction to quantum processes in MRI

  13. Clinical and MRI correlation in multiple system atrophy

    Energy Technology Data Exchange (ETDEWEB)

    Negoro, Kiyoshi; Morimatsu, Mitsunori (Yamaguchi Univ., Ube (Japan). School of Medicine)

    1994-05-01

    By using magnetic resonance imaging (MRI), we studied 11 patients with multiple system atrophy (MSA): 5 olivo-pontocerebellar atrophy (OPCA), 2 Shy-Drager syndrome (SDS), and 4 striatonigral degeneration (SND). The diagnoses of OPCA, SDS and SND were clinically made. The MR images were performed on 1.5 tesla MRI unit (Siemens Asahi Medical, Magnetom H15), using a T[sub 2]-weighted spin echo (SE) sequence (TR: 2000-3000 ms, TE: 80-90 ms), a T[sub 1]-weighted SE sequence (TR: 550, TE: 15), and a proton density-weighted (PD) SE sequence (TR: 2000-3000, TE: 12-22). In the patients with OPCA, MRI revealed cerebellar and brainstem atrophy and degeneration of pontine transverse fibers more marked than in the patients with SDS and SND. T[sub 2]-weighted images showed low intensity in posterolateral putamina in one OPCA patient and all of SDS and SND patients. PD images demonstrated the abnormal slit-like high signals in posterolateral putamina in three SND. The degree of cerebellar ataxia was not well correlated with cerebellar and brainstem atrophy and degeneration of pontine transverse fibers. There was a positive correlation between the atrophy of cerebellum and brainstem and the duration of cerebellar ataxia. In most of the patients with Parkinsonism, MRI demonstrated abnormal low signals in putamina on T[sub 2]-weighted images. There were positive correlations between the abnormal low signals putamina and the duration and severity of Parkinsonism. Though abnormal low signals in lateral putamina may be seen in normal aging and other disorders on T[sub 2]-weighted images, it is useful to evaluate Parkinsonism in MSA. We believe that the abnormal slit-like high signals in posterolateral putamina in MSA may suggest loss of neurons and gliosis. (author).

  14. Primary ureteral carcinoma: MRI diagnosis and comparison with other diagnostic imaging facilities

    International Nuclear Information System (INIS)

    An Ningyu; Jiang Bo; Cai Youquan; Liang Yan

    2004-01-01

    Objective: To investigate MRI examination methods and imaging manifestations of primary ureteral carcinoma, and to evaluate its clinical values when comparing with other diagnostic imaging facilities. Methods: Eighty-seven cases of primary ureteral carcinoma who were operated within recent 8 years came into the study, among which, 35 cases had MRI examinations. For MRI examination, coronal heavy T 2 WI (water imaging) was performed to show the dilated ureter, then axial T 2 WI and T 1 WI were scanned at the obstruction level. 11 cases underwent additional Gd-DTPA dynamic contrast enhanced scans. The original pre-operative diagnostic reports of various imaging facilities were analyzed comparing with the results of operation and pathology. Results: MRI showed ureteral dilatation in 33 of 35 cases, no abnormal appearance in 1 case, and only primary kidney atrophy post renal transplantation in 1 case. Among the 33 cases with ureteral obstruction, soft mass at the obstruction level was detected on axial scans in 32 cases. The lesions showed gradual and homogeneous mild to moderate enhancement on contrast MRI. The overall employment rate of imaging facilities was as follows: ultrasound (94.3%), IVU (59.8%), CT (52.9%), MRI (40.2%), and RUP (35.6%). The accurate diagnostic rate was as follows :MRI (91.4%), RUP (80.6%), CT (63.0%), ultrasound (47.6%), and IVU (11.5%). Conclusion: Combination of MR water imaging and conventional sequences can demonstrate most primary ureteral carcinoma lesions and has a highest diagnostic accuracy among the current diagnostic imaging facilities. It should be taken as the first diagnostic imaging method of choice when primary ureteral carcinoma is suspected after ultrasound screening

  15. Multiple imaging procedures including MRI for the bladder cancer

    International Nuclear Information System (INIS)

    Mikata, Noriharu; Suzuki, Makoto; Takeuchi, Takumi; Kunisawa, Yositaka; Fukutani, Keiko; Kawabe, Kazuki

    1986-01-01

    Endoscopic photography, double contrast cystography, transurethral echography, X-ray CT scan, and MRI (magnetic resonance imaging) were utilized for the staging diagnosis of the four patients with carcinoma of the bladder. In the first case, a 70-year-old man, since all of the five imaging procedures suggested a superficial and pedunculated tumor, his bladder cancer was considered T1. The classification of stage T3 carcinoma was made for the second 86-year-old male. Because all of his imaging examinations showed a tumor infiltrating deep muscle and penetrating the bladder wall. The third case was a 36-year-old male. His clinical stage was diagnosed as T2 or T3a by cystophotography, double contrast cystogram, ultrasonography, and X-ray CT scan. However, MRI showed only thickened bladder wall and the infiltrating tumor could not be distinguished from the hypertrophic wall. The last patient, a 85-year-old female, had a smaller Ta cancer. Her double contrast cystography revealed the small tumor at the lateral bladder wall. But, the tumor could not be detected by transaxial, sagittal and coronal scans. Multiple imaging procedures combining MRI and staging diagnosis of the bladder carcinoma were discussed. (author)

  16. Gadolinium-DTPA enhanced MRI in myocardial infarction. An experimental and clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Dijkman, P.R.M. van

    1991-10-30

    This thesis focuses on one aspect of cardiac magnetic resonance imaging (MRI) for noninvasive screening of ischemic heart disease: the identification and quantification of acutely infarcted myocardium using gadolineum-diethylene triamine pentaacetic acid (Gd-DTPA) enhanced T1-weighted MRI in a clinical and experimental setting. (author). 296 refs.; 34 figs.; 4 tabs.

  17. Visual grading of 2D and 3D functional MRI compared with image-based descriptive measures

    Energy Technology Data Exchange (ETDEWEB)

    Ragnehed, Mattias [Linkoeping University, Division of Radiological Sciences, Radiology, IMH, Linkoeping (Sweden); Linkoeping University, Center for Medical Image Science and Visualization, CMIV, Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences, Division of Radiological Sciences/Radiology, Faculty of Health Sciences, Linkoeping (Sweden); Leinhard, Olof Dahlqvist; Pihlsgaard, Johan; Lundberg, Peter [Linkoeping University, Center for Medical Image Science and Visualization, CMIV, Linkoeping (Sweden); Linkoeping University, Division of Radiological Sciences, Radiation Physics, IMH, Linkoeping (Sweden); Wirell, Staffan [Linkoeping University, Division of Radiological Sciences, Radiology, IMH, Linkoeping (Sweden); Linkoeping University Hospital, Department of Radiology, Linkoeping (Sweden); Soekjer, Hannibal; Faegerstam, Patrik [Linkoeping University Hospital, Department of Radiology, Linkoeping (Sweden); Jiang, Bo [Linkoeping University, Center for Medical Image Science and Visualization, CMIV, Linkoeping (Sweden); Smedby, Oerjan; Engstroem, Maria [Linkoeping University, Division of Radiological Sciences, Radiology, IMH, Linkoeping (Sweden); Linkoeping University, Center for Medical Image Science and Visualization, CMIV, Linkoeping (Sweden)

    2010-03-15

    A prerequisite for successful clinical use of functional magnetic resonance imaging (fMRI) is the selection of an appropriate imaging sequence. The aim of this study was to compare 2D and 3D fMRI sequences using different image quality assessment methods. Descriptive image measures, such as activation volume and temporal signal-to-noise ratio (TSNR), were compared with results from visual grading characteristics (VGC) analysis of the fMRI results. Significant differences in activation volume and TSNR were not directly reflected by differences in VGC scores. The results suggest that better performance on descriptive image measures is not always an indicator of improved diagnostic quality of the fMRI results. In addition to descriptive image measures, it is important to include measures of diagnostic quality when comparing different fMRI data acquisition methods. (orig.)

  18. Eosinophilic fasciitis in a military recruit: MRI evaluation with clinical correlation

    International Nuclear Information System (INIS)

    Liou, Chang-Hsien; Juan, Chun-Jung; Chen, Cheng-Yu.; Huang, Guo-Shu; Taylor, John A.M.; Gao, Hong-Wei

    2003-01-01

    Eosinophilic fasciitis (EF) is an uncommon connective tissue disease. We report a patient with EF who presented with episodic swelling and stiffness of his legs and forearms in combination with peripheral eosinophilia. Imaging studies of the legs and forearms, including computed tomography (CT) and magnetic resonance imaging (MRI), clearly demonstrated the characteristic finding of fascial thickening. The complete clinical imaging and pathological findings are described in this report. Cross-sectional imaging is useful in diagnosing EF and in the appropriate clinical scenario may be helpful in differentiating EF from other connective tissue diseases. (orig.)

  19. Three-dimensional contrasted visualization of pancreas in rats using clinical MRI and CT scanners.

    Science.gov (United States)

    Yin, Ting; Coudyzer, Walter; Peeters, Ronald; Liu, Yewei; Cona, Marlein Miranda; Feng, Yuanbo; Xia, Qian; Yu, Jie; Jiang, Yansheng; Dymarkowski, Steven; Huang, Gang; Chen, Feng; Oyen, Raymond; Ni, Yicheng

    2015-01-01

    The purpose of this work was to visualize the pancreas in post-mortem rats with local contrast medium infusion by three-dimensional (3D) magnetic resonance imaging (MRI) and computed tomography (CT) using clinical imagers. A total of 16 Sprague Dawley rats of about 300 g were used for the pancreas visualization. Following the baseline imaging, a mixed contrast medium dye called GadoIodo-EB containing optimized concentrations of Gd-DOTA, iomeprol and Evens blue was infused into the distally obstructed common bile duct (CBD) for post-contrast imaging with 3.0 T MRI and 128-slice CT scanners. Images were post-processed with the MeVisLab software package. MRI findings were co-registered with CT scans and validated with histomorphology, with relative contrast ratios quantified. Without contrast enhancement, the pancreas was indiscernible. After infusion of GadoIodo-EB solution, only the pancreatic region became outstandingly visible, as shown by 3D rendering MRI and CT and proven by colored dissection and histological examinations. The measured volume of the pancreas averaged 1.12 ± 0.04 cm(3) after standardization. Relative contrast ratios were 93.28 ± 34.61% and 26.45 ± 5.29% for MRI and CT respectively. We have developed a multifunctional contrast medium dye to help clearly visualize and delineate rat pancreas in situ using clinical MRI and CT scanners. The topographic landmarks thus created with 3D demonstration may help to provide guidelines for the next in vivo pancreatic MRI research in rodents. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Clinical applications of cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Marcu, C.B.; Beek, A.M.; Van Rossum, A.C.

    2006-01-01

    Cardiovascular magnetic resonance imaging (MRI) has evolved from an effective research tool into a clinically proven, safe and comprehensive imaging modality. It provides anatomic and functional information in acquired and congenital heart disease and is the most precise technique for quantification of ventricular volumes, function and mass. Owing to its excellent interstudy reproducibility, cardiovascular MRI is the optimal method for assessment of changes in ventricular parameters after therapeutic intervention. Delayed contrast enhancement is an accurate and robust method used in the diagnosis of ischemic and nonischemic cardiomyopathies and less common diseases, such as cardiac sarcoidosis and myocarditis. First-pass magnetic contrast myocardial perfusion is becoming an alternative to radionuclide techniques for the detection of coronary atherosclerotic disease. In this review we outline the techniques used in cardiovascular MRI and discuss the most common clinical applications. (author)

  1. Renal MRI findings and their clinical associations in nephropathia epidemica: analysis of quantitative findings

    Energy Technology Data Exchange (ETDEWEB)

    Paakkala, A. [University of Tampere, Medical School, Tampere (Finland); Tampere University Hospital, Department of Radiology, Tampere (Finland); Dastidar, P.; Ryymin, P. [Tampere University Hospital, Department of Radiology, Tampere (Finland); Huhtala, H. [University of Tampere, School of Public Health, Tampere (Finland); Mustonen, J. [University of Tampere, Medical School, Tampere (Finland); Tampere University Hospital, Department of Medicine, Tampere (Finland)

    2005-05-01

    Morphologic renal magnetic resonance imaging (MRI) findings in patients with nephropathia epidemica (NE) were evaluated, and these findings were correlated with the clinical course of NE. Renal MRI was performed in 20 hospitalized NE patients during the acute phase of their disease. A repeat MRI study was made 5-8 months later. Renal parenchymal volume, renal length and parenchymal thickness were decreased in all patients in the repeat study. Edema/fluid collections were found bilaterally in 16 patients in the primary MRI study. Greater change in parenchymal volume, renal length and parenchymal thickness between the primary and the repeat MRI study as well as the presence of edema/fluid collections in the primary study evinced mild association with clinical fluid volume overload, high blood pressure level, inflammation, thrombocytopenia and severe clinical renal insufficiency. Change in parenchymal volume was associated with a severe clinical course more markedly than the other MRI findings. Measurable renal MRI changes occurred in every NE patient. The severity of the findings in MRI evinced mild association with clinical fluid volume overload, high blood pressure level, inflammation, thrombocytopenia and severe clinical renal insufficiency. Based on this study and our previous ultrasound (US) findings, we prefer US as the primary examination mode in NE patients. (orig.)

  2. Renal MRI findings and their clinical associations in nephropathia epidemica: analysis of quantitative findings

    International Nuclear Information System (INIS)

    Paakkala, A.; Dastidar, P.; Ryymin, P.; Huhtala, H.; Mustonen, J.

    2005-01-01

    Morphologic renal magnetic resonance imaging (MRI) findings in patients with nephropathia epidemica (NE) were evaluated, and these findings were correlated with the clinical course of NE. Renal MRI was performed in 20 hospitalized NE patients during the acute phase of their disease. A repeat MRI study was made 5-8 months later. Renal parenchymal volume, renal length and parenchymal thickness were decreased in all patients in the repeat study. Edema/fluid collections were found bilaterally in 16 patients in the primary MRI study. Greater change in parenchymal volume, renal length and parenchymal thickness between the primary and the repeat MRI study as well as the presence of edema/fluid collections in the primary study evinced mild association with clinical fluid volume overload, high blood pressure level, inflammation, thrombocytopenia and severe clinical renal insufficiency. Change in parenchymal volume was associated with a severe clinical course more markedly than the other MRI findings. Measurable renal MRI changes occurred in every NE patient. The severity of the findings in MRI evinced mild association with clinical fluid volume overload, high blood pressure level, inflammation, thrombocytopenia and severe clinical renal insufficiency. Based on this study and our previous ultrasound (US) findings, we prefer US as the primary examination mode in NE patients. (orig.)

  3. Magnetic Resonance Imaging (MRI): Brain (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Magnetic Resonance Imaging (MRI): Brain KidsHealth / For Parents / Magnetic Resonance Imaging (MRI): Brain What's in this article? What ...

  4. Precise fusion of MRI and dual energy 111In WBC/99mTc HDP SPECT/CT in the diabetic foot using companion CT: an example of SPECT/MRI imaging

    International Nuclear Information System (INIS)

    Knešaurek, K.; Heiba, S.; Kolker, D.; Vatti, S.

    2015-01-01

    The purpose of our study was to correctly fuse MRI and SPECT 111 In WBC and 99m Tc HDP images using companion CT images. The fused images could be used to assess proper surgical approach in treatment of the diabetic foot. Nine patients who had dual energy 111 In WBC/ 99 m Tc HDP SPECT/CT and MRI studies within a week were investigated in an ongoing project. A GE Infinia SPECT/CT camera and Siemens MAGNETOM 1.5T MR system were used in this study. First, the MRI and corresponding CT images were coregistrated using a transformation based on normalized mutual information. The transformation was saved and used for MRI and 111 In WBC/ 99 m Tc HDP SPECT fusion. A Jaszczak phantom study was also performed in order to estimate accuracy of MRI/ SPECT fusion. The Jaszczak phantom study with 3.7 MBq 111 In hot sphere showed that MRI/SPECT alignment using the approach described above produced registration with 0.7±0.4 mm accuracy in all three dimensions (3D). The nine clinical cases were visually evaluated and showed 1-2 mm 3D fusion accuracy. MRI provides almost perfect anatomy of soft tissue and bony structures but it may exaggerate the extent of infection. 111 In WBC/ 99 m Tc HDP SPECT imaging is more accurate for infection detection but lacks anatomical reference. Combination of these images proved an essential adjunct to diagnosis. A clinical utility of the approach is illustrated in two clinical examples. In conclusion, the CT in dual energy 111 In WBC/ 99 m Tc HDP SPECT/CT studies can be used to accurately fuse and compare 111 In WBC/ 99 m Tc HDP SPECT and MRI images of the diabetic foot. This can significantly help in conservative treatment planning and limb salvage procedures in treatment of diabetic foot infections.

  5. Designing of superconducting magnet for clinical MRI

    International Nuclear Information System (INIS)

    Kar, Soumen; Choudhury, A.; Sharma, R.G.; Datta, T.S.

    2015-01-01

    Superconducting technology of Magnetic Resonance Imaging (MRI) scanner is closely guarded technology as it has huge commercial application for clinical diagnostics. This is a rapidly evolving technology which requires innovative design of magnetic and cryogenic system. A project on the indigenous development of 1.5 T (B_0) MRI scanner has been initiated by SAMEER, Mumbai funded by DeitY, Gov. of India. IUAC is the collaborating institute for designing and developing the superconducting magnets and the cryostat for 1.5 T MRI scanner. The superconducting magnet is heart of the present day MRI system. The performance of the magnet has the highest impact on the overall image quality of the scanner. The stringent requirement of the spatial homogeneity (few parts per million within 50 cm diametrical spherical volume), the temporal stability (0.1 ppm/hr.) of the superconducting magnet and the safety standard (5 G in 5 m x 3 m ellipsoidal space) makes the designing of the superconducting magnet more complex. MRI consists of set of main coils and shielding coils. The large ratio between the diameter and the winding length of each coil makes the B_p_e_a_k/B_0 ratio much higher, which makes complexity in selecting the load line of the magnet. Superconducting magnets will be made of NbTi wire-in-channel (WIC) conductor with high copper to superconducting (NbTi) ratio. Multi-coil configuration on multi-bobbin architecture is though is cost effective but poses complexity in the mechanical integration to achieve desired homogeneity. Some of the major sources of inhomogeneities, in a multi-bobbin configuration, are the imperfect axial positioning and angular shift. We have simulated several factors which causes the homogeneity in six (main) coils configuration for a 1.5 T MRI magnet. Differential thermal shrinkage between the bobbin and superconducting winding is also a major source of inhomogeneity in a MRI magnet. This paper briefly present the different designing aspects of the

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a ...

  7. Usefulness of magnetic resonance imaging (MRI) for patients with unilateral tinnitus

    Energy Technology Data Exchange (ETDEWEB)

    Katsura, Motoyasu [Sasebo Central Hospital, Nagasaki (Japan); Yoshida, Haruo; Kumagami, Hidetaka; Takahashi, Haruo [Nagasaki Univ. (Japan). Graduate School of Biomedical Sciences; Oosato, Yasuo [Sasebo City Hospital, Nagasaki (Japan); Dotsu, Mitsuru [National Nagasaki Medical Center, Omura (Japan)

    2004-06-01

    Audiography, X-ray (Stenvers view) and Magnetic Resonance Imaging (MRI) were performed on 88 patients exhibiting unilateral tinnitus. We diagnosed 4 cases (4.5%) of vestibular schwannoma and 41 cases (46.6%) of other abnormalities, including 2 cases of meningioma, 24 cases of old cerebral infarction, and 5 cases of mastoiditis. MRI was considered to be a first-line clinical examination for patients with unilateral tinnitus. (author)

  8. Usefulness of magnetic resonance imaging (MRI) for patients with unilateral tinnitus

    International Nuclear Information System (INIS)

    Katsura, Motoyasu; Yoshida, Haruo; Kumagami, Hidetaka; Takahashi, Haruo; Dotsu, Mitsuru

    2004-01-01

    Audiography, X-ray (Stenvers view) and Magnetic Resonance Imaging (MRI) were performed on 88 patients exhibiting unilateral tinnitus. We diagnosed 4 cases (4.5%) of vestibular schwannoma and 41 cases (46.6%) of other abnormalities, including 2 cases of meningioma, 24 cases of old cerebral infarction, and 5 cases of mastoiditis. MRI was considered to be a first-line clinical examination for patients with unilateral tinnitus. (author)

  9. Rapid ex vivo imaging of PAIII prostate to bone tumor with SWIFT-MRI.

    Science.gov (United States)

    Luhach, Ihor; Idiyatullin, Djaudat; Lynch, Conor C; Corum, Curt; Martinez, Gary V; Garwood, Michael; Gillies, Robert J

    2014-09-01

    The limiting factor for MRI of skeletal/mineralized tissue is fast transverse relaxation. A recent advancement in MRI technology, SWIFT (Sweep Imaging with Fourier Transform), is emerging as a new approach to overcome this difficulty. Among other techniques like UTE, ZTE, and WASPI, the application of SWIFT technology has the strong potential to impact preclinical and clinical imaging, particularly in the context of primary or metastatic bone cancers because it has the added advantage of imaging water in mineralized tissues of bone allowing MRI images to be obtained of tissues previously visible only with modalities such as computed tomography (CT). The goal of the current study is to examine the feasibility of SWIFT for the assessment of the prostate cancer induced changes in bone formation (osteogenesis) and destruction (osteolysis) in ex vivo specimens. A luciferase expressing prostate cancer cell line (PAIII) or saline control was inoculated directly into the tibia of 6-week-old immunocompromised male mice. Tumor growth was assessed weekly for 3 weeks before euthanasia and dissection of the tumor bearing and sham tibias. The ex vivo mouse tibia specimens were imaged with a 9.4 Tesla (T) and 7T MRI systems. SWIFT images are compared with traditional gradient-echo and spin-echo MRI images as well as CT and histological sections. SWIFT images with nominal resolution of 78 μm are obtained with the tumor and different bone structures identified. Prostate cancer induced changes in the bone microstructure are visible in SWIFT images, which is supported by spin-echo, high resolution CT and histological analysis. SWIFT MRI is capable of high-quality high-resolution ex vivo imaging of bone tumor and surrounding bone and soft tissues. Furthermore, SWIFT MRI shows promise for in vivo bone tumor imaging, with the added benefits of nonexposure to ionizing radiation, quietness, and speed. Copyright © 2013 Wiley Periodicals, Inc.

  10. Diagnosis of magnetic resonance imaging (MRI) for blowout fracture. Three advantages of MRI

    International Nuclear Information System (INIS)

    Nishida, Yasuhiro; Aoki, Yoshiko; Hayashi, Osamu; Kimura, Makiko; Murata, Toyotaka; Ishida, Youichi; Iwami, Tatsuya; Kani, Kazutaka

    1999-01-01

    Magnetic resonance imaging (MRI) gives a much more detailed picture of the soft tissue than computerized tomography (CT). In blowout fracture cases, it is very easy to observe the incarcerated orbital tissue. We performed MRI in 19 blowout fracture cases. After evaluating the images, we found three advantages of MRI. The first is that even small herniation of the orbital contents can easily be detected because the orbital fatty tissue contrasts well around the other tissues in MRI. The second is that the incarcerated tissues can be clearly differentiated because a clear contrast between the orbital fatty tissue and the extraocular muscle can be seen in MRI. The third is that the running images of the incarcerated muscle belly can be observed because any necessary directional slies can be taken in MRI. These advantages are very important in the diagnosis of blowout fractures. MRI should be employed in blowout fracture cases in addition to CT. (author)

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms that ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... room. In addition to affecting the MRI images, these objects can become projectiles within the MRI scanner ... may cause you and/or others nearby harm. These items include: jewelry, watches, credit cards and hearing ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... or headphones during the exam. MRI scanners are air-conditioned and well-lit. Music may be played ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will ... claustrophobia. Newer open MRI units provide very high quality images for many types of exams. Older open ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... used in tattoos may contain iron and could heat up during an MRI scan, but this is ... imaging based on the electrical activity of the heart, such as electrocardiography (EKG). MRI generally is not ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... MRI an invaluable tool in early diagnosis and evaluation of many conditions, including tumors. MRI enables the ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ... than 30 minutes from the onset of symptoms. Risks The MRI examination poses almost no risk to ...

  18. Positron emission tomography/magnetic resonance imaging (PET/MRI: An update and initial experience at HC-FMUSP

    Directory of Open Access Journals (Sweden)

    Marcelo A. Queiroz

    Full Text Available Summary The new technology of PET/MRI is a prototype of hybrid imaging, allowing for the combination of molecular data from PET scanning and morphofunctional information derived from MRI scanning. Recent advances regarding the technical aspects of this device, especially after the development of MRI-compatible silicon photomultipliers of PET, permitted an increase in the diagnostic performance of PET/MRI translated into dose reduction and higher imaging quality. Among several clinical applications, PET/MRI gains ground initially in oncology, where MRI per se plays an essential role in the assessment of primary tumors (which is limited in the case of PET/CT, including prostate, rectal and gynecological tumors. On the other hand, the evaluation of the lungs remains an enigma although new MRI sequences are being designed to overcome this. More clinical indications of PET/MRI are seen in the fields of neurology, cardiology and inflammatory processes, and the use of PET/MRI also opens perspectives for pediatric populations as it involves very low radiation exposure. Our review aimed to highlight the current indications of PET/MRI and discuss the challenges and perspectives of PET/MRI at HC-FMUSP.

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. ...

  20. Atlas-guided generation of pseudo-CT images for MRI-only and hybrid PET-MRI-guided radiotherapy treatment planning

    Science.gov (United States)

    Arabi, Hossein; Koutsouvelis, Nikolaos; Rouzaud, Michel; Miralbell, Raymond; Zaidi, Habib

    2016-09-01

    Magnetic resonance imaging (MRI)-guided attenuation correction (AC) of positron emission tomography (PET) data and/or radiation therapy (RT) treatment planning is challenged by the lack of a direct link between MRI voxel intensities and electron density. Therefore, even if this is not a trivial task, a pseudo-computed tomography (CT) image must be predicted from MRI alone. In this work, we propose a two-step (segmentation and fusion) atlas-based algorithm focusing on bone tissue identification to create a pseudo-CT image from conventional MRI sequences and evaluate its performance against the conventional MRI segmentation technique and a recently proposed multi-atlas approach. The clinical studies consisted of pelvic CT, PET and MRI scans of 12 patients with loco-regionally advanced rectal disease. In the first step, bone segmentation of the target image is optimized through local weighted atlas voting. The obtained bone map is then used to assess the quality of deformed atlases to perform voxel-wise weighted atlas fusion. To evaluate the performance of the method, a leave-one-out cross-validation (LOOCV) scheme was devised to find optimal parameters for the model. Geometric evaluation of the produced pseudo-CT images and quantitative analysis of the accuracy of PET AC were performed. Moreover, a dosimetric evaluation of volumetric modulated arc therapy photon treatment plans calculated using the different pseudo-CT images was carried out and compared to those produced using CT images serving as references. The pseudo-CT images produced using the proposed method exhibit bone identification accuracy of 0.89 based on the Dice similarity metric compared to 0.75 achieved by the other atlas-based method. The superior bone extraction resulted in a mean standard uptake value bias of  -1.5  ±  5.0% (mean  ±  SD) in bony structures compared to  -19.9  ±  11.8% and  -8.1  ±  8.2% achieved by MRI segmentation-based (water

  1. Unicompartmental knee arthroplasty MRI: impact of slice-encoding for metal artefact correction MRI on image quality, findings and therapy decision

    International Nuclear Information System (INIS)

    Agten, Christoph A.; Pfirrmann, Christian W.A.; Sutter, Reto; Grande, Filippo del; Fucentese, Sandro F.; Blatter, Samuel

    2015-01-01

    To evaluate the impact of slice-encoding for metal artefact correction (SEMAC) on image quality, findings, and therapy decision in patients with unicompartmental knee arthroplasty (UKA). Forty-five painful UKAs were examined at 1.5T-MRI (STIR, proton-density(PD)-weighted sequence, each with SEMAC and high-bandwidth). Artefact size, image quality, anatomic depiction, and clinically relevant findings were compared between SEMAC and high-bandwidth (2 readers). In 30 patients, therapy decision was retrospectively assessed by two orthopaedic surgeons without MRI, with high-bandwidth-MRI, and with SEMAC-MRI. SEMAC reduced mean artefact size for STIR (11.8 cm 2 vs. 37.7 cm 2 ) and PD (16.8 cm 2 vs. 18.9 cm 2 ), p < 0.0005 for both comparisons. SEMAC showed more blurring than high-bandwidth, p < 0.0005. STIR-SEMAC revealed more bone marrow oedema (29 vs. 18 patients, p = 0.001, 30 vs. 13 patients, p < 0.0005, for reader 1 and 2 respectively). PD-SEMAC was worse in detecting meniscal lesions (6 missed, p = 0.031, 9 missed, p = 0.004, by reader 1 and 2 respectively) than PD-high-bandwidth. Revision-surgery was chosen in 12 and 11 patients without MRI (surgeon 1 and 2), with high-bandwidth-MRI in 15 and 14 patients, and with SEMAC-MRI in 19 and 14 patients. STIR-SEMAC was useful in detecting bone marrow oedema and influenced the orthopaedic surgeons' decisions towards surgery, while PD-SEMAC showed no clinical benefit. (orig.)

  2. Clinical significance of magnetic resonance imaging (MRI) in evaluation of the extension of uterine cervical cancer

    International Nuclear Information System (INIS)

    Matsubara, Masaru

    1993-01-01

    Magnetic resonance imaging (MRI) was performed in 62 patients with uterine cervical cancer and the preoperative MRI findings were compared with the pathological findings following surgery. The surgical stages of 62 patients were 2 at stage 0, 18 at stage Ia, 19 at stage Ib, 9 at stage IIa, 11 at stage IIb, 2 at stage IIIa, and 1 at stage IIIb. The MRI findings in the present study included: (1) the existence of a high intensity area (HIA) in the uterine cervix or minimum thickness of residual normal cervical tissue, (2) necrotic cavity, (3) pyometra, (4) irregular margin of the cervix, (5) parametrial invasion, (6) vaginal invasion, (7) bladder invasion, and (8) lymph node enlargement. No HIA was observed in any patient with stage 0 or stage Ia, in 8 patients with stage Ib, and in 2 patients with stage IIa, while all patients with cancer tissues greater than 10 mm in diameter had a HIA. In 39 patients in whom hysterectomy was undergone without conization, the findings of MRI correlated significantly (r=0.929, p<0.001) with the minimum thickness of residual normal cervical tissue by the pathological measurement. When the irregular margin of the cervix was regarded as a disruption of the cervical myo-metrium by cancer tissue, accuracy was 87%. Furthermore, the degrees of accuracy for parametrial invasion, vaginal invasion and bladder invasion were 92%, 90% and 94%, respectively. When lymphnodes greater than 15 mm in diameter were regarded as a positive in MRI, accuracy was 88%. The present results indicate that MRI is clinically effective in preoperatively evaluating the extension of uterine cervical cancer. (author)

  3. Real-Time MRI Navigated Ultrasound for Preoperative Tumor Evaluation in Breast Cancer Patients: Technique and Clinical Implementation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ah Young; Seo, Bo Kyoung [Department of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan 15355 (Korea, Republic of)

    2016-11-01

    Real-time magnetic resonance imaging (MRI) navigated ultrasound is an image fusion technique to display the results of both MRI and ultrasonography on the same monitor. This system is a promising technique to improve lesion detection and analysis, to maximize advantages of each imaging modality, and to compensate the disadvantages of both MRI and ultrasound. In evaluating breast cancer stage preoperatively, MRI and ultrasound are the most representative imaging modalities. However, sometimes difficulties arise in interpreting and correlating the radiological features between these two different modalities. This pictorial essay demonstrates the technical principles of the real-time MRI navigated ultrasound, and clinical implementation of the system in preoperative evaluation of tumor extent, multiplicity, and nodal status in breast cancer patients.

  4. Real-time MRI navigated ultrasound for preoperative tumor evaluation in breast cancer patients: Technique and clinical implementation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ah Young; Seo, Bo Kyoung [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of)

    2016-09-15

    Real-time magnetic resonance imaging (MRI) navigated ultrasound is an image fusion technique to display the results of both MRI and ultrasonography on the same monitor. This system is a promising technique to improve lesion detection and analysis, to maximize advantages of each imaging modality, and to compensate the disadvantages of both MRI and ultrasound. In evaluating breast cancer stage preoperatively, MRI and ultrasound are the most representative imaging modalities. However, sometimes difficulties arise in interpreting and correlating the radiological features between these two different modalities. This pictorial essay demonstrates the technical principles of the real-time MRI navigated ultrasound, and clinical implementation of the system in preoperative evaluation of tumor extent, multiplicity, and nodal status in breast cancer patients.

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... absolutely necessary for medical treatment. See the MRI Safety page for more information about pregnancy and MRI. ...

  7. Signal to noise comparison of metabolic imaging methods on a clinical 3T MRI

    DEFF Research Database (Denmark)

    Müller, C. A.; Hansen, Rie Beck; Skinner, J. G.

    MRI with hyperpolarized tracers has enabled new diagnostic applications, e.g. metabolic imaging in cancer research. However, the acquisition of the transient, hyperpolarized signal with spatial and frequency resolution requires dedicated imaging methods. Here, we compare three promising candidate...... for 2D MR spectroscopic imaging (MRSI): (i) multi-echo balanced steady-state free precession (me-bSSFP), 1,2 (ii) echo planar spectroscopic imaging (EPSI) sequence and (iii) phase-encoded, pulseacquisition chemical-shift imaging (CSI)...

  8. Hemodynamic measurement using four-dimensional phase-contrast MRI: Quantification of hemodynamic parameters and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Ho Jin; Lee, Sang Joon [POSTECH Biotech Center, Pohang University of Science and Technology, Pohang (Korea, Republic of); Kim, Guk Bae; Kweon, Ji Hoon; Kim, Young Hak; Lee, Deok Hee; Yang, Dong Hyun; KIm, Nam Kug [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    Recent improvements have been made to the use of time-resolved, three-dimensional phase-contrast (PC) magnetic resonance imaging (MRI), which is also named four-dimensional (4D) PC-MRI or 4D flow MRI, in the investigation of spatial and temporal variations in hemodynamic features in cardiovascular blood flow. The present article reviews the principle and analytical procedures of 4D PC-MRI. Various fluid dynamic biomarkers for possible clinical usage are also described, including wall shear stress, turbulent kinetic energy, and relative pressure. Lastly, this article provides an overview of the clinical applications of 4D PC-MRI in various cardiovascular regions.

  9. Hemodynamic Measurement Using Four-Dimensional Phase-Contrast MRI: Quantification of Hemodynamic Parameters and Clinical Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Hojin [POSTECH Biotech Center, Pohang University of Science and Technology, Pohang 37673 (Korea, Republic of); Kim, Guk Bae [Asan Institute of Life Science, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505 (Korea, Republic of); Kweon, Jihoon [Department of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505 (Korea, Republic of); Lee, Sang Joon [POSTECH Biotech Center, Pohang University of Science and Technology, Pohang 37673 (Korea, Republic of); Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang 37673 (Korea, Republic of); Kim, Young-Hak [Department of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505 (Korea, Republic of); Lee, Deok Hee; Yang, Dong Hyun [Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505 (Korea, Republic of); Kim, Namkug [Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505 (Korea, Republic of); Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505 (Korea, Republic of)

    2016-11-01

    Recent improvements have been made to the use of time-resolved, three-dimensional phase-contrast (PC) magnetic resonance imaging (MRI), which is also named four-dimensional (4D) PC-MRI or 4D flow MRI, in the investigation of spatial and temporal variations in hemodynamic features in cardiovascular blood flow. The present article reviews the principle and analytical procedures of 4D PC-MRI. Various fluid dynamic biomarkers for possible clinical usage are also described, including wall shear stress, turbulent kinetic energy, and relative pressure. Lastly, this article provides an overview of the clinical applications of 4D PC-MRI in various cardiovascular regions.

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. People with the ...

  11. Clinical application of functional MRI for chronic epilepsy

    International Nuclear Information System (INIS)

    Woermann, F.G.; Labudda, K.

    2010-01-01

    Functional magnetic resonance imaging (fMRI) is frequently used in the presurgical diagnostic procedure of epilepsy patients, in particular for lateralization of speech and memory and for localization of the primary motor cortex to delineate the epileptogenic lesion from eloquent brain areas. fMRI is one of the non-invasive procedures in the presurgical diagnostic process, together with medical history, seizure semiology, neurological examination, interictal and ictal EEG, structural MRI, video EEG monitoring and neuropsychology. This diagnostic sequence leads either to the decision for or against elective epilepsy surgery or to the decision to proceed with invasive diagnostic techniques (Wada test, intra-operative or extra-operative cortical stimulation). It is difficult to evaluate the contribution of the fMRI test in isolation to the validity of the entire diagnostic sequence. Complications such as memory loss and aphasia in temporal lobe resections or paresis after frontal lobe resections are rare and rarely of disastrous extent. This further complicates the evaluation of the clinical relevance of fMRI as a predictive tool. In this article studies which investigated the concordance between fMRI and other diagnostic gold standards will be presented as well as the association between presurgical fMRI and postsurgical morbidity. (orig.) [de

  12. Simultaneous MRI and PET imaging of a rat brain

    Energy Technology Data Exchange (ETDEWEB)

    Raylman, Raymond R [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States); Majewski, Stan [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Lemieux, Susan K [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States); Velan, S Sendhil [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States); Kross, Brian [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Popov, Vladimir [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Smith, Mark F [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Weisenberger, Andrew G [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Zorn, Carl [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Marano, Gary D [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States)

    2006-12-21

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI will allow the correlation of form with function. Our group is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode. Each MRI-PET detector module consists of an array of LSO detector elements coupled through a long fibre optic light guide to a single Hamamatsu flat panel position-sensitive photomultiplier tube (PSPMT). The use of light guides allows the PSPMTs to be positioned outside the bore of a 3T MRI scanner where the magnetic field is relatively small. To test the device, simultaneous MRI and PET images of the brain of a male Sprague Dawley rat injected with FDG were successfully obtained. The images revealed no noticeable artefacts in either image set. Future work includes the construction of a full ring PET scanner, improved light guides and construction of a specialized MRI coil to permit higher quality MRI imaging.

  13. Simultaneous MRI and PET imaging of a rat brain

    International Nuclear Information System (INIS)

    Raylman, Raymond R; Majewski, Stan; Lemieux, Susan K; Velan, S Sendhil; Kross, Brian; Popov, Vladimir; Smith, Mark F; Weisenberger, Andrew G; Zorn, Carl; Marano, Gary D

    2006-01-01

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI will allow the correlation of form with function. Our group is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode. Each MRI-PET detector module consists of an array of LSO detector elements coupled through a long fibre optic light guide to a single Hamamatsu flat panel position-sensitive photomultiplier tube (PSPMT). The use of light guides allows the PSPMTs to be positioned outside the bore of a 3T MRI scanner where the magnetic field is relatively small. To test the device, simultaneous MRI and PET images of the brain of a male Sprague Dawley rat injected with FDG were successfully obtained. The images revealed no noticeable artefacts in either image set. Future work includes the construction of a full ring PET scanner, improved light guides and construction of a specialized MRI coil to permit higher quality MRI imaging

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the scheduler before the exam and bring ... Image Gallery Magnetic Resonance Imaging (MRI) procedure View full size with caption Pediatric Content Some imaging tests ...

  15. Obesity and rates of clinical remission and low MRI inflammation in rheumatoid arthritis

    DEFF Research Database (Denmark)

    George, Michael D.; Østergaard, Mikkel; Conaghan, Philip G.

    2017-01-01

    Objectives O besity has been proposed as a risk factor for refractory rheumatoid arthritis (RA). We evaluated the impact of obesity on achieving clinical and imaging definitions of low disease activity. Methods T his study evaluated 470 patients with RA from GO-BEFORE and GO-FORWARD randomised...... clinical trials. Included patients had blinded clinical disease activity measures and MRI at baseline, 24 and 52 weeks. Synovitis, osteitis and total inflammation scores were determined using the RA MRI scoring system. Multivariable logistic regression analyses compared odds of achieving Disease Activity...

  16. MRI-powered biomedical devices.

    Science.gov (United States)

    Hovet, Sierra; Ren, Hongliang; Xu, Sheng; Wood, Bradford; Tokuda, Junichi; Tse, Zion Tsz Ho

    2017-11-16

    Magnetic resonance imaging (MRI) is beneficial for imaging-guided procedures because it provides higher resolution images and better soft tissue contrast than computed tomography (CT), ultrasound, and X-ray. MRI can be used to streamline diagnostics and treatment because it does not require patients to be repositioned between scans of different areas of the body. It is even possible to use MRI to visualize, power, and control medical devices inside the human body to access remote locations and perform minimally invasive procedures. Therefore, MR conditional medical devices have the potential to improve a wide variety of medical procedures; this potential is explored in terms of practical considerations pertaining to clinical applications and the MRI environment. Recent advancements in this field are introduced with a review of clinically relevant research in the areas of interventional tools, endovascular microbots, and closed-loop controlled MRI robots. Challenges related to technology and clinical feasibility are discussed, including MRI based propulsion and control, navigation of medical devices through the human body, clinical adoptability, and regulatory issues. The development of MRI-powered medical devices is an emerging field, but the potential clinical impact of these devices is promising.

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... As the hydrogen atoms return to their usual alignment, they emit different amounts of energy that vary ... story about radiology? Share your patient story here Images × Image Gallery Magnetic Resonance Imaging (MRI) procedure View ...

  18. Clinical and MRI features of supratentorial gliomas with adult-onset epilepsy

    International Nuclear Information System (INIS)

    Hashimoto, Takahiro; Yamaura, Akira; Watanabe, Osamu.

    1992-01-01

    Although some patients with supratentorial gliomas develop epilepsy in their clinical course, the details of adult-onset epilepsy with gliomas have not been fully evaluated. This paper reports on 15 cases of supratentorial glioma with the sole symptom of adult-onset epilepsy and characterizes their clinical and MRI features. The patients, 5 males and 10 females, developed the first epilepsy at the mean age of 37 years. Generalized seizure was encountered in all cases and focal seizure alone was never seen. Seizure was satisfactorily controlled with anticonvulsants in all except 2 cases. The tumor was located in the frontal lobe (9 cases) or temporal lobe (6 cases). Histologically, there were 12 astrocytomas, 2 glioblastomas, and 1 oligoastrocytoma. Of these, 12 were benign gliomas. Surprisingly, CT scan and MRI revealed tumors larger than predicted. The abnormal intensity region was delineated most prominently on T 2 -weighted SE image and was broader on T 2 -weighted spin echo image than on T 1 -weighted spin echo and inversion recovery image. The authors conclude that gliomas presenting with epilepsy tend to be histologically benign, are predominantly seen in middle-aged women, and are located in the frontal and temporal lobes. Although a tumor may be large enough to be detected on CT scan or MRI, as in the present study, histological examination is needed to establish the diagnosis. Additionally, gliomas with equivocal abnormalities on CT and MRI do evolve despite further neurological deficits, so meticulous evaluation including stereotactic biopsy is the method of choice. Finally, T 2 -weighted SE image in the coronal plane is advocated for patients with adult-onset epilepsy to achieve accurate diagnosis and to initiate early treatment. (author)

  19. Imaging diagnosis in relapsing polychondritis and correlation with clinical and serological data

    International Nuclear Information System (INIS)

    Thaiss, W.M.; Nikolaou, K.; Horger, M.; Spengler, W.; Xenitidis, T.; Henes, J.; Spira, D.

    2016-01-01

    We hypothesize that imaging findings from CT and MRI correlate better with clinical markers for assessment of disease activity in patients with the rare relapsing polychondritis (RPC) than with serological inflammatory markers. Retrospective database search at our institution identified 28 patients (13 females; age 49.0 years ± 15.0 SD) with RP between September 2004 and March 2014. Institutional review board approval was obtained for this retrospective data analysis. All patients had clinically proven RPC with at least two episodes of active disease. Of those, 18 patients were examined with CT- and MRI and presented all morphologic features of RPC like bronchial/laryngeal/auricular cartilage thickness, contrast enhancement, increased T2-signal intensity. Imaging data was subsequently correlated with corresponding clinical symptoms like fever, dyspnea, stridor, uveitis, pain, hearing impairment as well as with acute-phase-inflammatory parameters like C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR). The clinical parameters were in good agreement with imaging findings and clinical symptoms such as tracheal wall thickening and dyspnea (r =0.65 p = 0.05), joint synovitis on MRI and a higher McAdam score (r = 0.84 p < 0.001). No correlations were found between inflammatory laboratory markers, imaging findings and clinical features. Imaging diagnosis in RPC using CT and/or MRI delivers information about the degree of disease activity that correlates better with clinical features than unspecific inflammatory laboratory markers. Additionally, clinically unapparent cartilage involvement can be assessed adding value to the clinical diagnosis and therapy planning in this rare disease. (orig.)

  20. Imaging diagnosis in relapsing polychondritis and correlation with clinical and serological data

    Energy Technology Data Exchange (ETDEWEB)

    Thaiss, W.M.; Nikolaou, K.; Horger, M. [Eberhard Karls University, Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen (Germany); Spengler, W.; Xenitidis, T.; Henes, J. [Eberhard Karls University, Department of Internal Medicine II, Tuebingen (Germany); Spira, D. [Eberhard Karls University, Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen (Germany); University Medical Center Heidelberg, Diagnostic and Interventional Radiology, Heidelberg (Germany)

    2016-03-15

    We hypothesize that imaging findings from CT and MRI correlate better with clinical markers for assessment of disease activity in patients with the rare relapsing polychondritis (RPC) than with serological inflammatory markers. Retrospective database search at our institution identified 28 patients (13 females; age 49.0 years ± 15.0 SD) with RP between September 2004 and March 2014. Institutional review board approval was obtained for this retrospective data analysis. All patients had clinically proven RPC with at least two episodes of active disease. Of those, 18 patients were examined with CT- and MRI and presented all morphologic features of RPC like bronchial/laryngeal/auricular cartilage thickness, contrast enhancement, increased T2-signal intensity. Imaging data was subsequently correlated with corresponding clinical symptoms like fever, dyspnea, stridor, uveitis, pain, hearing impairment as well as with acute-phase-inflammatory parameters like C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR). The clinical parameters were in good agreement with imaging findings and clinical symptoms such as tracheal wall thickening and dyspnea (r =0.65 p = 0.05), joint synovitis on MRI and a higher McAdam score (r = 0.84 p < 0.001). No correlations were found between inflammatory laboratory markers, imaging findings and clinical features. Imaging diagnosis in RPC using CT and/or MRI delivers information about the degree of disease activity that correlates better with clinical features than unspecific inflammatory laboratory markers. Additionally, clinically unapparent cartilage involvement can be assessed adding value to the clinical diagnosis and therapy planning in this rare disease. (orig.)

  1. Use of personal computer image for processing a magnetic resonance image (MRI)

    International Nuclear Information System (INIS)

    Yamamoto, Tetsuo; Tanaka, Hitoshi

    1988-01-01

    Image processing of MR imaging was attempted by using a popular personal computer as 16-bit model. The computer processed the images on a 256 x 256 matrix and 512 x 512 matrix. The softwer languages for image-processing were those of Macro-Assembler performed by (MS-DOS). The original images, acuired with an 0.5 T superconducting machine (VISTA MR 0.5 T, Picker International) were transfered to the computer by the flexible disket. Image process are the display of image to monitor, other the contrast enhancement, the unsharped mask contrast enhancement, the various filter process, the edge detections or the color histogram was obtained in 1.6 sec to 67 sec, indicating that commercialzed personal computer had ability for routine clinical purpose in MRI-processing. (author)

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Imaging (MRI) procedure View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  3. TH-A-BRF-11: Image Intensity Non-Uniformities Between MRI Simulation and Diagnostic MRI

    International Nuclear Information System (INIS)

    Paulson, E

    2014-01-01

    Purpose: MRI simulation for MRI-based radiotherapy demands that patients be setup in treatment position, which frequently involves use of alternative radiofrequency (RF) coil configurations to accommodate immobilized patients. However, alternative RF coil geometries may exacerbate image intensity non-uniformities (IINU) beyond those observed in diagnostic MRI, which may challenge image segmentation and registration accuracy as well as confound studies assessing radiotherapy response when MR simulation images are used as baselines for evaluation. The goal of this work was to determine whether differences in IINU exist between MR simulation and diagnostic MR images. Methods: ACR-MRI phantom images were acquired at 3T using a spin-echo sequence (TE/TR:20/500ms, rBW:62.5kHz, TH/skip:5/5mm). MR simulation images were obtained by wrapping two flexible phased-array RF coils around the phantom. Diagnostic MR images were obtained by placing the phantom into a commercial phased-array head coil. Pre-scan normalization was enabled in both cases. Images were transferred offline and corrected for IINU using the MNI N3 algorithm. Coefficients of variation (CV=σ/μ) were calculated for each slice. Wilcoxon matched-pairs and Mann-Whitney tests compared CV values between original and N3 images and between MR simulation and diagnostic MR images. Results: Significant differences in CV were detected between original and N3 images in both MRI simulation and diagnostic MRI groups (p=0.010, p=0.010). In addition, significant differences in CV were detected between original MR simulation and original and N3 diagnostic MR images (p=0.0256, p=0.0016). However, no significant differences in CV were detected between N3 MR simulation images and original or N3 diagnostic MR images, demonstrating the importance of correcting MR simulation images beyond pre-scan normalization prior to use in radiotherapy. Conclusions: Alternative RF coil configurations used in MRI simulation can Result in

  4. A clinical study on the usefulness of CT and MRI imaging in evaluating differential diagnosis and the degree of dementia in vascular dementia

    Energy Technology Data Exchange (ETDEWEB)

    Hagiwara, Mariko [Nippon Medical School, Tokyo (Japan)

    1990-06-01

    In a retrospective review of 117 computed tomography (CT) scans and 56 magnetic resonance imaging (MRI) scans sequentially performed for dementia patients, CT and MRI were compared for assessment of the usefulness in the differential diagnosis and determination of the functional prognosis of vascular dementia. The correlation between CT findings and the degree of mental function was also examined. Since MRI had a higher sensitivity than CT in detecting small infarcts or lacunaes in the perforating area or white matter, it should differentiate vascular dementia from dementia of Alzheimer type. When both dementia of Alzheimer type was clinically diagnosed and infarct areas were detected on either CT or MRI, activity of daily living tended to be poor. Even when mixed type of dementia or vascular dementia was clinically diagnosed in spite of negative findings on either CT or MRI, troublesome behavior was frequently observed, posing the likelihood of dementia of Alzheimer type. The ability of CT and MRI to detect lesions was not correlated with the degree of dementia or aging, even if MRI was capable of detecting smaller lesions. CT was thus considered to be more specific modality for evaluating mental function. The size of lesions on CT was found to be more significant than the number and localization of lesions in determining the degree of dementia in the chronic stage of cerebrovascular disease. The ability of MRI to detect smaller lesions, as well as clinically determined ischemic scores, may assist in the diagnostic differentiation. Lesion size on CT may be an important factor for determining the degree of dementia and functional prognosis. (N.K.).

  5. A clinical study on the usefulness of CT and MRI imaging in evaluating differential diagnosis and the degree of dementia in vascular dementia

    International Nuclear Information System (INIS)

    Hagiwara, Mariko

    1990-01-01

    In a retrospective review of 117 computed tomography (CT) scans and 56 magnetic resonance imaging (MRI) scans sequentially performed for dementia patients, CT and MRI were compared for assessment of the usefulness in the differential diagnosis and determination of the functional prognosis of vascular dementia. The correlation between CT findings and the degree of mental function was also examined. Since MRI had a higher sensitivity than CT in detecting small infarcts or lacunaes in the perforating area or white matter, it should differentiate vascular dementia from dementia of Alzheimer type. When both dementia of Alzheimer type was clinically diagnosed and infarct areas were detected on either CT or MRI, activity of daily living tended to be poor. Even when mixed type of dementia or vascular dementia was clinically diagnosed in spite of negative findings on either CT or MRI, troublesome behavior was frequently observed, posing the likelihood of dementia of Alzheimer type. The ability of CT and MRI to detect lesions was not correlated with the degree of dementia or aging, even if MRI was capable of detecting smaller lesions. CT was thus considered to be more specific modality for evaluating mental function. The size of lesions on CT was found to be more significant than the number and localization of lesions in determining the degree of dementia in the chronic stage of cerebrovascular disease. The ability of MRI to detect smaller lesions, as well as clinically determined ischemic scores, may assist in the diagnostic differentiation. Lesion size on CT may be an important factor for determining the degree of dementia and functional prognosis. (N.K.)

  6. Translating state-of-the-art spinal cord MRI techniques to clinical use: A systematic review of clinical studies utilizing DTI, MT, MWF, MRS, and fMRI.

    Science.gov (United States)

    Martin, Allan R; Aleksanderek, Izabela; Cohen-Adad, Julien; Tarmohamed, Zenovia; Tetreault, Lindsay; Smith, Nathaniel; Cadotte, David W; Crawley, Adrian; Ginsberg, Howard; Mikulis, David J; Fehlings, Michael G

    2016-01-01

    A recent meeting of international imaging experts sponsored by the International Spinal Research Trust (ISRT) and the Wings for Life Foundation identified 5 state-of-the-art MRI techniques with potential to transform the field of spinal cord imaging by elucidating elements of the microstructure and function: diffusion tensor imaging (DTI), magnetization transfer (MT), myelin water fraction (MWF), MR spectroscopy (MRS), and functional MRI (fMRI). However, the progress toward clinical translation of these techniques has not been established. A systematic review of the English literature was conducted using MEDLINE, MEDLINE-in-Progress, Embase, and Cochrane databases to identify all human studies that investigated utility, in terms of diagnosis, correlation with disability, and prediction of outcomes, of these promising techniques in pathologies affecting the spinal cord. Data regarding study design, subject characteristics, MRI methods, clinical measures of impairment, and analysis techniques were extracted and tabulated to identify trends and commonalities. The studies were assessed for risk of bias, and the overall quality of evidence was assessed for each specific finding using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework. A total of 6597 unique citations were identified in the database search, and after full-text review of 274 articles, a total of 104 relevant studies were identified for final inclusion (97% from the initial database search). Among these, 69 studies utilized DTI and 25 used MT, with both techniques showing an increased number of publications in recent years. The review also identified 1 MWF study, 11 MRS studies, and 8 fMRI studies. Most of the studies were exploratory in nature, lacking a priori hypotheses and showing a high (72%) or moderately high (20%) risk of bias, due to issues with study design, acquisition techniques, and analysis methods. The acquisitions for each technique varied widely across

  7. Unicompartmental knee arthroplasty MRI: impact of slice-encoding for metal artefact correction MRI on image quality, findings and therapy decision

    Energy Technology Data Exchange (ETDEWEB)

    Agten, Christoph A.; Pfirrmann, Christian W.A.; Sutter, Reto [Balgrist University Hospital, Radiology Department, Zurich (Switzerland); University of Zurich, Faculty of Medicine, Zurich (Switzerland); Grande, Filippo del [Regional Hospital, Radiology, Lugano (Switzerland); Fucentese, Sandro F.; Blatter, Samuel [University of Zurich, Faculty of Medicine, Zurich (Switzerland); Balgrist University Hospital, Orthopedics, Zurich (Switzerland)

    2015-07-15

    To evaluate the impact of slice-encoding for metal artefact correction (SEMAC) on image quality, findings, and therapy decision in patients with unicompartmental knee arthroplasty (UKA). Forty-five painful UKAs were examined at 1.5T-MRI (STIR, proton-density(PD)-weighted sequence, each with SEMAC and high-bandwidth). Artefact size, image quality, anatomic depiction, and clinically relevant findings were compared between SEMAC and high-bandwidth (2 readers). In 30 patients, therapy decision was retrospectively assessed by two orthopaedic surgeons without MRI, with high-bandwidth-MRI, and with SEMAC-MRI. SEMAC reduced mean artefact size for STIR (11.8 cm{sup 2} vs. 37.7 cm{sup 2}) and PD (16.8 cm{sup 2} vs. 18.9 cm{sup 2}), p < 0.0005 for both comparisons. SEMAC showed more blurring than high-bandwidth, p < 0.0005. STIR-SEMAC revealed more bone marrow oedema (29 vs. 18 patients, p = 0.001, 30 vs. 13 patients, p < 0.0005, for reader 1 and 2 respectively). PD-SEMAC was worse in detecting meniscal lesions (6 missed, p = 0.031, 9 missed, p = 0.004, by reader 1 and 2 respectively) than PD-high-bandwidth. Revision-surgery was chosen in 12 and 11 patients without MRI (surgeon 1 and 2), with high-bandwidth-MRI in 15 and 14 patients, and with SEMAC-MRI in 19 and 14 patients. STIR-SEMAC was useful in detecting bone marrow oedema and influenced the orthopaedic surgeons' decisions towards surgery, while PD-SEMAC showed no clinical benefit. (orig.)

  8. FWFusion: Fuzzy Whale Fusion model for MRI multimodal image ...

    Indian Academy of Sciences (India)

    Hanmant Venketrao Patil

    2018-03-14

    Mar 14, 2018 ... consider multi-modality medical images other than PET and MRI images. ... cipal component averaging based on DWT for fusing CT-. MRI and MRI ..... sub-band LH of the fused image, the distance measure is given based on the ...... sustainable integrated dynamic ship routing and scheduling optimization.

  9. MRI and associated clinical characteristics of EV71-induced brainstem encephalitis in children with hand-foot-mouth disease

    International Nuclear Information System (INIS)

    Zeng, Hongwu; Gan, Yungen; Wen, Feiqiu; Huang, Wenxian

    2012-01-01

    This study was conducted to investigate MRI and associated clinical characteristics of brainstem encephalitis induced by enterovirus 71 (EV71) in children with hand-foot-mouth disease (HFMD). We analyzed clinical and imaging data from 42 HFMD cases with EV71-induced brainstem encephalitis. All patients underwent plain and enhanced MRI cranial scans and were placed into one of two groups according to MRI enhancement results, an enhanced group or a nonenhanced group. Thirty-two cases were positive on MRI exam. The primary location of the lesion for brainstem encephalitis was the dorsal pons and medulla oblongata (32 cases), followed by the cerebellar dentate nucleus (8 cases), midbrain (5 cases), and thalamus (2 cases). Plain T1-weighted images showed isointense or hypointense signals, and T2-weighted images showed isointense and hyperintense signals. Enhanced MRI scans showed that 12 cases had slight to moderate enhancement; 4 of these were normal on plain scan. The time from MRI examination to disease onset was statistically different between the enhanced (n = 12) and nonenhanced (n = 21) groups with a mean of 7.67 days (SD = 1.07) vs 11.95 days (SD = 5.33), respectively. The most common neurological symptoms for brainstem encephalitis were myoclonus and tremor. The greater the area of affected brain, the more severe the clinical symptoms were. The locations of EV71-induced HFMD-associated brainstem encephalitis lesions are relatively specific. Enhanced MRI scans could also identify the lesions missed by early plain scans. MRI scans can provide important information for clinical evaluation and treatment. (orig.)

  10. MRI and associated clinical characteristics of EV71-induced brainstem encephalitis in children with hand-foot-mouth disease

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Hongwu; Gan, Yungen [Shenzhen Children' s Hospital, Department of Radiology, Shenzhen (China); Wen, Feiqiu [Shenzhen Children' s Hospital, Department of Neurology, Shenzhen (China); Huang, Wenxian [Shenzhen Children' s Hospital, Department of Respiratory, Shenzhen (China)

    2012-06-15

    This study was conducted to investigate MRI and associated clinical characteristics of brainstem encephalitis induced by enterovirus 71 (EV71) in children with hand-foot-mouth disease (HFMD). We analyzed clinical and imaging data from 42 HFMD cases with EV71-induced brainstem encephalitis. All patients underwent plain and enhanced MRI cranial scans and were placed into one of two groups according to MRI enhancement results, an enhanced group or a nonenhanced group. Thirty-two cases were positive on MRI exam. The primary location of the lesion for brainstem encephalitis was the dorsal pons and medulla oblongata (32 cases), followed by the cerebellar dentate nucleus (8 cases), midbrain (5 cases), and thalamus (2 cases). Plain T1-weighted images showed isointense or hypointense signals, and T2-weighted images showed isointense and hyperintense signals. Enhanced MRI scans showed that 12 cases had slight to moderate enhancement; 4 of these were normal on plain scan. The time from MRI examination to disease onset was statistically different between the enhanced (n = 12) and nonenhanced (n = 21) groups with a mean of 7.67 days (SD = 1.07) vs 11.95 days (SD = 5.33), respectively. The most common neurological symptoms for brainstem encephalitis were myoclonus and tremor. The greater the area of affected brain, the more severe the clinical symptoms were. The locations of EV71-induced HFMD-associated brainstem encephalitis lesions are relatively specific. Enhanced MRI scans could also identify the lesions missed by early plain scans. MRI scans can provide important information for clinical evaluation and treatment. (orig.)

  11. MRI in sporadic Creutzfeldt-Jakob disease: Correlation with clinical and neuropathological data

    International Nuclear Information System (INIS)

    Urbach, H.; Solymosi, L.; Klisch, J.; Brechtelsbauer, D.; Wolf, H.K.; Gass, S.

    1998-01-01

    To ascertain whether increased grey matter signal intensity on T2-weighted images in patients with sporadic Creutzfeldt-Jakob disease (CJD) corresponds to the stage and severity of this disease, we correlated MRI findings in four of our own and previously reported patients with sporadic CJD with the clinical variants, neuropathological changes at autopsy, duration of the disease and survival time after MRI examination. Of 15 patients with the extrapyramidal type of CJD, 10 showed increased signal in the basal ganglia on T2-weighted images. One of seven patients with the Heidenhain variant had increased signal in the occipital cortex. Patients without increased grey matter signal intensity had a longer overall duration of CJD (P = 0.035). Although the interval between onset of neurological symptoms and MRI was not different, patients without increased grey matter signal also survived longer after MRI examination (P = 0.022). (orig.)

  12. Indications and value of bone scintigraphy in comparison to magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Haug, A.; Hacker, M.; Weiss, M.; Hahn, K.; Pfluger, T.

    2006-01-01

    With increasing use of cross-sectional imaging (CT/MRI) in radiology as well as PET and PET/CT in nuclear medicine, remaining indications for bone scintigraphy are in question. Recently introduced whole-body MRI represents an attractive alternative to bone scintigraphy, as MRI is additionally able to assess lesions that are limited to bone marrow and are located extraosseously. In this overview, indication-related strengths and limitations of MRI and bone scintigraphy are presented and discussed. Furthermore, complementary use of both modalities for special clinical questions is demonstrated. (orig.)

  13. Clinical significance of reduced cerebral metabolism in multiple sclerosis. A combined PET and MRI study

    International Nuclear Information System (INIS)

    Sun, Xiayan; Tanaka, Makoto; Kondo, Susumu; Okamoto, Koichi; Hirai, Shunsaku

    1998-01-01

    Magnetic resonance imaging (MRI) in patients with multiple sclerosis (MS) has provided major insights into the disease's natural history, and many studies have focussed on possible correlations between MRI findings and the clinical manifestations of MS. In contrast, there are few reports on possible relationships between functional imaging data and cognitive function. The present study assessed the relationship between clinical presentation and combined anatomical and functional imaging data in MS. Twenty patients with definite MS underwent MRI and positron emission tomography (PET) to evaluate cerebral blood flow (rCBF) and oxygen metabolism (rCMRO 2 ). The relationships between these neuroimaging findings and clinical data, including the Expanded Disability Status Scale (EDSS), Mini-mental status scale, Hasegawa Dementia Scale and relapse time, were evaluated with Spearman's rank correlation coefficients. A general reduction in rCBF and rCMRO 2 in the gray and white matter were found in the MS patients. EDSS was correlated with the number and size of the lesions on MRI and was negatively correlated with rCMRO 2 . A correlation between the decrease in rCMRO 2 and the level of cognitive impairment was also found. The severity of cerebral hypometabolism was also related to the number of relapses. Morphological and functional findings obtained by MRI and PET are closely related to the clinical status in MS. Our results suggest that measurement of cerebral metabolism in MS has the potential to be an objective marker for monitoring disease activity and to provide prognostic information. (author)

  14. Actual imaging time in fetal MRI

    International Nuclear Information System (INIS)

    Brugger, Peter C.; Prayer, Daniela

    2012-01-01

    Objective: Safety issues in magnetic resonance imaging (MRI) are important, especially in fetal MRI. However, since basic data with respect of the effective exposure time in fetal MRI are not available, this study aimed to determine the actual imaging time during a fetal MRI study. Methods: 100 fetal MRI studies of singleton pregnancies performed on a 1.5 T system were analysed with respect to study duration (from starting the survey scan until the end of study), the number of sequences acquired, and the actual imaging time, which was calculated by adding up scan time of each sequence. Furthermore, each sequence type was analysed regarding the number of acquisitions, specific absorption rates (SAR), and duration. Results: Mean study duration was 34.6 min (range: 14–58 min; standard deviation (SD): 9.7 min), the average number of sequences acquired was 26.6 (range: 11–44, SD: 6.6). Actual scan time averaged 11.4 min (range: 4–19 min, SD: 4.0 min). Ultrafast T2-weighted and steady-state free-precession sequences accounted for 62.3% of actual scan time, and were distributed over the whole duration of the study. Conclusion: Actual imaging time only accounts for 33% of total study time and is not continuous. The remaining time is consumed by the preparation phases of the scanner, and is spent with planning sequences and the eventual repositioning of the coil and/or pregnant woman. These data may help to more accurately estimate the exposure to radiofrequency deposition and noise during fetal MRI studies.

  15. Advances in PET-MRI technology

    International Nuclear Information System (INIS)

    Chen Xiang; Zhao Jinhua

    2011-01-01

    Multimodality imaging is the general trend of clinical imaging. PET-CT is one of the most classic and mature multimodality imaging methods and is widely used today. MRI is another kind of conventional imaging method, in contrast to CT, MRI can not only yield images with higher soft-tissue contrast and better spatial resolution resolution but also provide some functional information by special imaging techniques such as MRS. The combination of PET and MRI for simultaneous data acquisition should have far-reaching consequences for clinical and scientific study. This review describes the progress to date and talks about the problems met in the development of PET-MRI and look forward to its potential application. (authors)

  16. Audit of a policy of magnetic resonance imaging with diffusion-weighted imaging as first-line neuroimaging for in-patients with clinically suspected acute stroke

    International Nuclear Information System (INIS)

    Buckley, B.T.; Wainwright, A.; Meagher, T.; Briley, D.

    2003-01-01

    AIM: To audit the feasibility and use of diffusion-weighted (DW) magnetic resonance imaging (MRI) as initial neuroimaging for in-patients with clinically suspected acute stroke. MATERIALS AND METHODS: In April 2000, MRI with DW and T2-weighted sequence was locally instituted as initial neuroimaging for patients with clinically suspected acute stroke. This retrospective study reviewed imaging performed for in-patients with suspected acute stroke over a 9-month period. Data were collected on image type, result and need for repeat imaging. RESULTS: During the study period, 124 patients had neuroimaging for suspected cerebrovascular accident, and 119 were MRI safe. Eighty-eight (73.9%) patients underwent DW MRI as first-line investigation. Five patients were not MRI safe and 31 had computed tomography (CT) as first-line imaging due to lack of available MRI capacity. Repeat neuroimaging was performed in 16 (12.9%) patients. Study times were comparable for both types of neuroimaging: a mean of 13 min for MRI and 11 min for CT. CONCLUSION: The audit standard was achieved in 88 (73.9%) patients. The use of DW MRI as a first-line investigation for patients with a clinical diagnosis of acute stroke is achievable in a district general hospital setting

  17. Audit of a policy of magnetic resonance imaging with diffusion-weighted imaging as first-line neuroimaging for in-patients with clinically suspected acute stroke

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, B.T.; Wainwright, A.; Meagher, T.; Briley, D

    2003-03-01

    AIM: To audit the feasibility and use of diffusion-weighted (DW) magnetic resonance imaging (MRI) as initial neuroimaging for in-patients with clinically suspected acute stroke. MATERIALS AND METHODS: In April 2000, MRI with DW and T2-weighted sequence was locally instituted as initial neuroimaging for patients with clinically suspected acute stroke. This retrospective study reviewed imaging performed for in-patients with suspected acute stroke over a 9-month period. Data were collected on image type, result and need for repeat imaging. RESULTS: During the study period, 124 patients had neuroimaging for suspected cerebrovascular accident, and 119 were MRI safe. Eighty-eight (73.9%) patients underwent DW MRI as first-line investigation. Five patients were not MRI safe and 31 had computed tomography (CT) as first-line imaging due to lack of available MRI capacity. Repeat neuroimaging was performed in 16 (12.9%) patients. Study times were comparable for both types of neuroimaging: a mean of 13 min for MRI and 11 min for CT. CONCLUSION: The audit standard was achieved in 88 (73.9%) patients. The use of DW MRI as a first-line investigation for patients with a clinical diagnosis of acute stroke is achievable in a district general hospital setting.

  18. Neonatal Pulmonary MRI of Bronchopulmonary Dysplasia Predicts Short-term Clinical Outcomes.

    Science.gov (United States)

    Higano, Nara S; Spielberg, David R; Fleck, Robert J; Schapiro, Andrew H; Walkup, Laura L; Hahn, Andrew D; Tkach, Jean A; Kingma, Paul S; Merhar, Stephanie L; Fain, Sean B; Woods, Jason C

    2018-05-23

    Bronchopulmonary dysplasia (BPD) is a serious neonatal pulmonary condition associated with premature birth, but the underlying parenchymal disease and trajectory are poorly characterized. The current NICHD/NHLBI definition of BPD severity is based on degree of prematurity and extent of oxygen requirement. However, no clear link exists between initial diagnosis and clinical outcomes. We hypothesized that magnetic resonance imaging (MRI) of structural parenchymal abnormalities will correlate with NICHD-defined BPD disease severity and predict short-term respiratory outcomes. Forty-two neonates (20 severe BPD, 6 moderate, 7 mild, 9 non-BPD controls; 40±3 weeks post-menstrual age) underwent quiet-breathing structural pulmonary MRI (ultrashort echo-time and gradient echo) in a NICU-sited, neonatal-sized 1.5T scanner, without sedation or respiratory support unless already clinically prescribed. Disease severity was scored independently by two radiologists. Mean scores were compared to clinical severity and short-term respiratory outcomes. Outcomes were predicted using univariate and multivariable models including clinical data and scores. MRI scores significantly correlated with severities and predicted respiratory support at NICU discharge (P<0.0001). In multivariable models, MRI scores were by far the strongest predictor of respiratory support duration over clinical data, including birth weight and gestational age. Notably, NICHD severity level was not predictive of discharge support. Quiet-breathing neonatal pulmonary MRI can independently assess structural abnormalities of BPD, describe disease severity, and predict short-term outcomes more accurately than any individual standard clinical measure. Importantly, this non-ionizing technique can be implemented to phenotype disease and has potential to serially assess efficacy of individualized therapies.

  19. Recent topics in NMR imaging and MRI

    International Nuclear Information System (INIS)

    Watanabe, Tokuko

    2002-01-01

    NMR and NMR imaging (MRI) are finding increasing use not only in the clinical and medical fields, but also in material, physicochemical, biological, geological, industrial and environmental applications. This short review is limited to two topics: new techniques and pulse sequences and their application to non-clinical fields that may have clinical application; and new trends in MR contrast agents. The former topic addresses pulse sequence and data analysis; dynamics such as diffusion, flow, velocity and velocimetry; chemometrics; pharmacological agents; and chemotherapy; the latter topic addresses contrast agents (CA) sensitive to biochemical activity; CA based on water exchange; molecular interactions and stability of CA; characteristics of emerging CA; superparamagnetic CA; and macromolecular CA. (author)

  20. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    International Nuclear Information System (INIS)

    Ma, J; Son, J; Arun, B; Hazle, J; Hwang, K; Madewell, J; Yang, W; Dogan, B; Wang, K; Bayram, E

    2016-01-01

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the

  1. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    Energy Technology Data Exchange (ETDEWEB)

    Ma, J; Son, J; Arun, B; Hazle, J; Hwang, K; Madewell, J; Yang, W; Dogan, B [UT MD Anderson Cancer Center, Houston, TX (United States); Wang, K; Bayram, E [GE Healthcare Technologies, Waukesha, Wisconsin (United States)

    2016-06-15

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the

  2. Magnetic Resonance Imaging (MRI): Lumbar Spine (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Magnetic Resonance Imaging (MRI): Lumbar Spine KidsHealth / For Parents / Magnetic Resonance Imaging (MRI): Lumbar Spine What's in this article? ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... fitting and has no metal fasteners. Guidelines about eating and drinking before an MRI exam vary with the specific exam and with the imaging facility. Unless you are told otherwise, you may follow your regular daily routine and take food and medications as usual. Some MRI examinations may ...

  4. Whole-body MRI in patients with Non-bacterial Osteitis: Radiological findings and correlation with clinical data

    Energy Technology Data Exchange (ETDEWEB)

    Arnoldi, A.P.; Geyer, L.L. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich (Germany); Schlett, C.L.; Weckbach, S. [University Hospital Heidelberg, Diagnostic and Interventional Radiology, Heidelberg (Germany); Douis, H. [University Hospital Birmingham, Department of Radiology, Birmingham (United Kingdom); Voit, A.M.; Bleisteiner, F.; Jansson, A.F. [Dr. von Hauner Children' s Hospital, Ludwig-Maximilians-University, Department of Rheumatology and Immunology, Munich (Germany)

    2017-06-15

    To correlate clinical findings of Non-bacterial Osteitis (NBO) with whole-body MRI (WB-MRI) findings and determine a radiologic index for NBO (RINBO) which allows standardized reporting of WB-MRI. In a prospective study, 40 patients with diagnosis of NBO underwent clinical examination and WB-MRI in which STIR- and T1- weighted images were assessed for NBO-typical lesions. Parameters of interest for RINBO were: number of radiologically active lesions (RAL), size of the patients' maximum RAL presence of extramedullary and spinal involvement. Results were tested for statistical agreement of clinical and MR-based lesion detection. RINBO was tested for correlation with clinical activity. 62/95 clinically/radiologically active lesions were found in 30/33 patients. In 45 % of the cohort, more active lesions were detected by WB-MRI than by clinical examination. RINBO was a significant predictor for the presence of clinically active lesions. WB-MRI is a powerful diagnostic tool for patients with NBO which can reveal asymptomatic disease activity. With RINBO a standardized evaluation approach is proposed which helps assessing radiologic disease burden and predicts clinical disease activity. (orig.)

  5. MRI imaging in pediatric appendicitis

    Directory of Open Access Journals (Sweden)

    Robin Riley

    2018-04-01

    Full Text Available An 8-year-old male presents with two days of abdominal pain and emesis. Computed tomography was concerning for obstruction or reactive ileus with an apparent transition point in the right lower quadrant, possibly due to Crohn's. Magnetic resonance imaging was concerning for perforated appendicitis. As demonstrated by this case MRI can be as sensitive as CT in detecting pediatric appendicitis [2]. We recommend using MRI instead of CT to diagnose appendicitis to avoid ionizing radiation and increased cancer risk in the pediatric population. Keywords: Computer tomography, Magnetic resonance imaging, Pediatric appendicitis

  6. WE-DE-206-00: MRI Physics

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Magnetic resonance imaging (MRI) has become an essential part of clinical imaging due to its ability to render high soft tissue contrast. Instead of ionizing radiation, MRI use strong magnetic field, radio frequency waves and field gradients to create diagnostic useful images. It can be used to image the anatomy and also functional and physiological activities within the human body. Knowledge of the basic physical principles underlying MRI acquisition is vitally important to successful image production and proper image interpretation. This lecture will give an overview of the spin physics, imaging principle of MRI, the hardware of the MRI scanner, and various pulse sequences and their applications. It aims to provide a conceptual foundation to understand the image formation process of a clinical MRI scanner. Learning Objectives: Understand the origin of the MR signal and contrast from the spin physics level. Understand the main hardware components of a MRI scanner and their purposes Understand steps for MR image formation including spatial encoding and image reconstruction Understand the main kinds of MR pulse sequences and their characteristics.

  7. Clinical and MRI features of supratentorial gliomas with adult-onset epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takahiro; Yamaura, Akira (Chiba Univ. (Japan). School of Medicine); Watanabe, Osamu

    1992-02-01

    Although some patients with supratentorial gliomas develop epilepsy in their clinical course, the details of adult-onset epilepsy with gliomas have not been fully evaluated. This paper reports on 15 cases of supratentorial glioma with the sole symptom of adult-onset epilepsy and characterizes their clinical and MRI features. The patients, 5 males and 10 females, developed the first epilepsy at the mean age of 37 years. Generalized seizure was encountered in all cases and focal seizure alone was never seen. Seizure was satisfactorily controlled with anticonvulsants in all except 2 cases. The tumor was located in the frontal lobe (9 cases) or temporal lobe (6 cases). Histologically, there were 12 astrocytomas, 2 glioblastomas, and 1 oligoastrocytoma. Of these, 12 were benign gliomas. Surprisingly, CT scan and MRI revealed tumors larger than predicted. The abnormal intensity region was delineated most prominently on T[sub 2]-weighted SE image and was broader on T[sub 2]-weighted spin echo image than on T[sub 1]-weighted spin echo and inversion recovery image. The authors conclude that gliomas presenting with epilepsy tend to be histologically benign, are predominantly seen in middle-aged women, and are located in the frontal and temporal lobes. Although a tumor may be large enough to be detected on CT scan or MRI, as in the present study, histological examination is needed to establish the diagnosis. Additionally, gliomas with equivocal abnormalities on CT and MRI do evolve despite further neurological deficits, so meticulous evaluation including stereotactic biopsy is the method of choice. Finally, T[sub 2]-weighted SE image in the coronal plane is advocated for patients with adult-onset epilepsy to achieve accurate diagnosis and to initiate early treatment. (author).

  8. Imaging of tumor viability in lung cancer. Initial results using 23Na-MRI

    International Nuclear Information System (INIS)

    Henzler, T.; Apfaltrer, P.; Haneder, S.; Schoenberg, S.O.; Fink, C.; Konstandin, S.; Schad, L.; Schmid-Bindert, G.; Manegold, C.; Wenz, F.

    2012-01-01

    23 Na-MRI has been proposed as a potential imaging biomarker for the assessment of tumor viability and the evaluation of therapy response but has not yet been evaluated in patients with lung cancer. We aimed to assess the feasibility of 23 Na-MRI in patients with lung cancer. Three patients with stage IV adenocarcinoma of the lung were examined on a clinical 3 Tesla MRI system (Magnetom TimTrio, Siemens Healthcare, Erlangen, Germany). Feasibility of 23 Na-MRI images was proven by comparison and fusion of 23 Na-MRI with 1 H-MR, CT and FDG-PET-CT images. 23 Na signal intensities (SI) of tumor and cerebrospinal fluid (CSF) of the spinal canal were measured and the SI ratio in tumor and CSF was calculated. One chemonaive patient was examined before and after the initiation of combination therapy (Carboplatin, Gemcitabin, Cetuximab). All 23 Na-MRI examinations were successfully completed and were of diagnostic quality. Fusion of 23 Na-MRI images with 1 H-MRI, CT and FDG-PET-CT was feasible in all patients and showed differences in solid and necrotic tumor areas. The mean tumor SI and the tumor/CSF SI ratio were 13.3 ± 1.8 x 103 and 0.83 ± 0.14, respectively. In necrotic tumors, as suggested by central non-FDG-avid areas, the mean tumor SI and the tumor/CSF ratio were 19.4 x 103 and 1.10, respectively. 23 Na-MRI is feasible in patients with lung cancer and could provide valuable functional molecular information regarding tumor viability, and potentially treatment response. (orig.)

  9. MRI in sporadic Creutzfeldt-Jakob disease: Correlation with clinical and neuropathological data

    Energy Technology Data Exchange (ETDEWEB)

    Urbach, H.; Solymosi, L. [Department of Neuroradiology, University of Wuerzburg (Germany); Klisch, J.; Brechtelsbauer, D. [Department of Neuroradiology, University of Bonn, Bonn (Germany); Wolf, H.K. [Department of Neuropathology, University of Bonn, Bonn (Germany); Gass, S. [Department of Neurology, University of Bonn, Bonn (Germany)

    1998-02-01

    To ascertain whether increased grey matter signal intensity on T2-weighted images in patients with sporadic Creutzfeldt-Jakob disease (CJD) corresponds to the stage and severity of this disease, we correlated MRI findings in four of our own and previously reported patients with sporadic CJD with the clinical variants, neuropathological changes at autopsy, duration of the disease and survival time after MRI examination. Of 15 patients with the extrapyramidal type of CJD, 10 showed increased signal in the basal ganglia on T2-weighted images. One of seven patients with the Heidenhain variant had increased signal in the occipital cortex. Patients without increased grey matter signal intensity had a longer overall duration of CJD (P = 0.035). Although the interval between onset of neurological symptoms and MRI was not different, patients without increased grey matter signal also survived longer after MRI examination (P = 0.022). (orig.) With 5 figs., 2 tabs., 23 refs.

  10. The use of MRI and CT in Imaging Occult Hip Fractures

    Directory of Open Access Journals (Sweden)

    Obadă B.

    2014-11-01

    Full Text Available Diagnosis of hip fractures is particularly important due to the high dependence on the integrity of this structure for people to function in their daily lives. Left unrecognized, patients face increasing morbidity and mortality as time from the original injury lengthens. A delay of just 2 days in surgical treatment for an acute hip fracture doubles mortality. In addition, an unrecognized non-displaced fracture may displace, requiring surgery of much higher risk. This may be part of the reason that the most frequent lawsuit against Emergency Physicians is for missed orthopedic injury. We reviewed the use of MRI and CT for occult hip fractures (OHF detection at a major urban trauma unit. Our study is a retrospective review. Inclusion criteria: all patients presenting to the Emergency Clinical Hospital of Constanta with a suspected, posttraumatic, occult hip fracture, over a 5 years period were included. All patients had negative initial radiographs and underwent further imaging with either CT or MRI. A total of 185 cases meeting the inclusion criteria were identified. 72 occult hip fractures were detected with both imaging modalities. Although MRI certainly enables greater image detail, in our experience both modalities are able to provide satisfactory fracture characterization. The choice of imaging should be determined by availability and indication. MRI provides superior imaging of soft tissue but is less sensitive for degenerative changes in presence of bone edema.

  11. Clinical investigation on usefulness of MRI in the diagnosis of mediastinal masses

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Takao (Kagoshima Univ. (Japan). Faculty of Medicine)

    1994-02-01

    This study evaluated the utility of magnetic resonance imaging (MRI) in diagnosing mediastinal masses. The subjects were 96 patients with pathologically (n=82) and clinically (n=14) proven mediastinal masses, consisting of thymomas (30), teratomas (4), other thymic tumors (5), intrathoracic goiters (4), neurogenic tumors (7), congenital cysts (12), mesenchymal tumors (10), vascular masses (5), phrenic hernia (3), malignant lymphomas (6), and sarcoidosis (10). MRI findings, including marginal and capsular appearances, internal structures and signal intensities, were analyzed. Internal structure characteristic to thymomas were seen in 24 teratoma patients (80%). In 4 teratomas, MRI was capable of distinguishing benign (2) from malignant (2) ones. In the other 5 thymic tumors, MRI delineated chemical characteristics of fluids for thymic cysts (2) and internal structures for thymic cancer (2) and lipoma (one). It also delineated the continuity of intrathoracic goiter from the cervical to intrathoracic regions. For neurogenic tumors, MRI was capable of distinguishing neurofibromas from schwannomas and also benign from malignant schwannomas. A well-defined smooth margin and very high signal intensity, which were characteristic to congenital cysts, were seen on T2-weighted images. Signal intensities on T1-weighted images reflected fluid features in cysts. For mesenchymal tumors, consisting of hemangioma, hemangiosarcoma, malignant melanoma, aneurysmal bone cyst and osteosarcoma, lymphangioma and chondrosarcoma, all but osteosarcoma showed their respective characteristic MRI findings. Vascular masses were delineated as flow void structures. MRI delineated herniated contents. Malignant lymphoma was shown as irregular and inhomogeneous swollen lymph nodes, but sarcoidosis was shown as regular and homogeneous ones on MRI. In conclusion, MRI is a useful, informative modality for diagnosing mediastinal masses. (N.K.) 84 refs.

  12. Clinical investigation on usefulness of MRI in the diagnosis of mediastinal masses

    International Nuclear Information System (INIS)

    Oyama, Takao

    1994-01-01

    This study evaluated the utility of magnetic resonance imaging (MRI) in diagnosing mediastinal masses. The subjects were 96 patients with pathologically (n=82) and clinically (n=14) proven mediastinal masses, consisting of thymomas (30), teratomas (4), other thymic tumors (5), intrathoracic goiters (4), neurogenic tumors (7), congenital cysts (12), mesenchymal tumors (10), vascular masses (5), phrenic hernia (3), malignant lymphomas (6), and sarcoidosis (10). MRI findings, including marginal and capsular appearances, internal structures and signal intensities, were analyzed. Internal structure characteristic to thymomas were seen in 24 teratoma patients (80%). In 4 teratomas, MRI was capable of distinguishing benign (2) from malignant (2) ones. In the other 5 thymic tumors, MRI delineated chemical characteristics of fluids for thymic cysts (2) and internal structures for thymic cancer (2) and lipoma (one). It also delineated the continuity of intrathoracic goiter from the cervical to intrathoracic regions. For neurogenic tumors, MRI was capable of distinguishing neurofibromas from schwannomas and also benign from malignant schwannomas. A well-defined smooth margin and very high signal intensity, which were characteristic to congenital cysts, were seen on T2-weighted images. Signal intensities on T1-weighted images reflected fluid features in cysts. For mesenchymal tumors, consisting of hemangioma, hemangiosarcoma, malignant melanoma, aneurysmal bone cyst and osteosarcoma, lymphangioma and chondrosarcoma, all but osteosarcoma showed their respective characteristic MRI findings. Vascular masses were delineated as flow void structures. MRI delineated herniated contents. Malignant lymphoma was shown as irregular and inhomogeneous swollen lymph nodes, but sarcoidosis was shown as regular and homogeneous ones on MRI. In conclusion, MRI is a useful, informative modality for diagnosing mediastinal masses. (N.K.) 84 refs

  13. MR-Imaging of teeth and periodontal apparatus: an experimental study comparing high-resolution MRI with MDCT and CBCT

    International Nuclear Information System (INIS)

    Gaudino, Chiara; Csernus, Reka; Pham, Mirko; Bendszus, Martin; Rohde, Stefan; Cosgarea, Raluca; Kim, Ti-Sun; Heiland, Sabine; Beomonte Zobel, Bruno

    2011-01-01

    The aim of this study was (1) to assess the ability of magnetic resonance imaging (MRI) to visualize dental and periodontal structures and (2) to compare findings with multidetector computed tomography (MDCT) and cone beam CT (CBCT). Four porcine mandibles were examined with (1) 3T-MRI, (2) MDCT and (3) CBCT. Two observers independently reviewed MR, MDCT and CBCT images and assessed image quality of different dental and periodontal structures. To assess quantitatively the accuracy of the different imaging technique, both observers measured burr holes, previously drilled in the mandibles. Dental structures, e.g. teeth roots, pulpa chamber and dentin, were imaged accurately with all imaging sources. Periodontal space and cortical/trabecular bone were better visualized by MRI (p < 0.001). MRI could excellently display the lamina dura, not detectable with MDCT and only inconstant visible with CBCT (p < 0.001). Burr hole measurements were highly precise with all imaging techniques. This experimental study shows the diagnostic feasibility of MRI in visualization of teeth and periodontal anatomy. Detection of periodontal structures was significantly better with MRI than with MDCT or CBCT. Prospective trials have to evaluate further the potential benefit of MRI in a clinical setting. (orig.)

  14. MR-Imaging of teeth and periodontal apparatus: an experimental study comparing high-resolution MRI with MDCT and CBCT

    Energy Technology Data Exchange (ETDEWEB)

    Gaudino, Chiara; Csernus, Reka; Pham, Mirko; Bendszus, Martin; Rohde, Stefan [University Hospital Heidelberg, Department of Neuroradiology, Heidelberg (Germany); Cosgarea, Raluca; Kim, Ti-Sun [University Hospital Heidelberg, Department of Periodontology, Heidelberg (Germany); Heiland, Sabine [University Hospital Heidelberg, Section of Experimental Radiology, Heidelberg (Germany); Beomonte Zobel, Bruno [University Campus Bio-Medico of Rome, Department of Radiology, Interdisciplinary Center for Biomedical Research, Rome (Italy)

    2011-12-15

    The aim of this study was (1) to assess the ability of magnetic resonance imaging (MRI) to visualize dental and periodontal structures and (2) to compare findings with multidetector computed tomography (MDCT) and cone beam CT (CBCT). Four porcine mandibles were examined with (1) 3T-MRI, (2) MDCT and (3) CBCT. Two observers independently reviewed MR, MDCT and CBCT images and assessed image quality of different dental and periodontal structures. To assess quantitatively the accuracy of the different imaging technique, both observers measured burr holes, previously drilled in the mandibles. Dental structures, e.g. teeth roots, pulpa chamber and dentin, were imaged accurately with all imaging sources. Periodontal space and cortical/trabecular bone were better visualized by MRI (p < 0.001). MRI could excellently display the lamina dura, not detectable with MDCT and only inconstant visible with CBCT (p < 0.001). Burr hole measurements were highly precise with all imaging techniques. This experimental study shows the diagnostic feasibility of MRI in visualization of teeth and periodontal anatomy. Detection of periodontal structures was significantly better with MRI than with MDCT or CBCT. Prospective trials have to evaluate further the potential benefit of MRI in a clinical setting. (orig.)

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - ...

  16. Differential diagnosis of truly suprasellar space-occupying masses: synopsis of clinical findings, CT, and MRI

    International Nuclear Information System (INIS)

    Reul, J.; Weis, J.; Spetzger, U.; Isensee, C.; Thron, A.

    1995-01-01

    This review demonstrates the features of truly suprasellar masses in modern imaging based on the clinical, CT, and MRI findings of 42 patients with suprasellar masses in correlation to the histologic findings. The radiologic examinations were evaluated retrospectively to determine if diagnosis can be made based on specific imaging patterns. The most frequent clinical findings of space-occupying suprasellar masses were visual disturbances, diabetes insipidus, and symptoms and signs of occlusive hydrocephalus. There were no clinical features specific for any of the observed masses. Craniopharyngiomas were the most frequent tumors. They appeared in two different forms, as cystic and as solid enhancing masses. The cystic tumors could not be differentiated from cystic hamartomas or cystic gliomas by CT or MRI. The solid craniopharyngiomas were similar to meningiomas and hamartomas. In craniopharyngiomas of adults calcifications were not common. In CT and especially in MRI gliomas were characterized by the diffuse infiltration of the adjacent brain tissue or optic nerve. Except for meningiomas, all lesions were highly variable in appearance, making a reliable characterization by CT and MRI difficult in many cases. However, administration of contrast media in some cases resulted in a better tumor delineation. Compared with unenhanced MRI the enhanced scans did not increase diagnostic efficacy for neoplasms, but were helpful in the differentiation from inflammatory diseases. The MRI technique was superior to CT in demonstrating the anatomic relationships, thus facilitating evaluation of origin and extent of the lesions. The CT technique, of course, was more reliable in the detection of calcifications. Both CT and MRI are not tissue-specific, however, and suprasellar tumors as well as many other neoplasms cannot be classified using only one of these imaging techniques. (orig.)

  17. Diagnostic precision of PET imaging and functional MRI in disorders of consciousness

    DEFF Research Database (Denmark)

    Stender, Johan; Gosseries, Olivia; Bruno, Marie-Aurélie

    2014-01-01

    a validation study of two neuroimaging-based diagnostic methods: PET imaging and functional MRI (fMRI). METHODS: For this clinical validation study, we included patients referred to the University Hospital of Liège, Belgium, between January, 2008, and June, 2012, who were diagnosed by our unit...... with unresponsive wakefulness syndrome, locked-in syndrome, or minimally conscious state with traumatic or non-traumatic causes. We did repeated standardised clinical assessments with the Coma Recovery Scale-Revised (CRS-R), cerebral (18)F-fluorodeoxyglucose (FDG) PET, and fMRI during mental activation tasks. We...... state (48=traumatic, 78=non-traumatic; 110=chronic, 16=subacute). (18)F-FDG PET had high sensitivity for identification of patients in a minimally conscious state (93%, 95% CI 85-98) and high congruence (85%, 77-90) with behavioural CRS-R scores. The active fMRI method was less sensitive at diagnosis...

  18. MRI findings in the patients with the presumptive clinical diagnosis of Tolosa-Hunt syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Cakirer, Sinan [Department of Radiology, Neuroradiology Section, Istanbul Sisli Etfal Hospital, 81120 Istanbul (Turkey)

    2003-01-01

    The aim of this study was to present our experience in MRI diagnosis of 23 patients with the clinical findings suggesting Tolosa-Hunt syndrome (THS). Cranial MRI studies of the patients with a clinical history of at least one episode of unilateral or bilateral orbital and periorbital pain, and associated paresis of one or more of third to sixth cranial nerves, were performed on a 1.5-T MRI scanner. Whereas 5 patients had the diagnosis of THS, paracavernous meningiomas in 4 patients, pituitary macroadenomas with cavernous sinus infiltration in 3 patients, Meckel's cave neurinoma in 1 patient, and suprasellar epidermoid in 1 patient were surgically proven MRI findings. Other pathological MRI findings were leptomeningeal metastases in 3 patients, granulomatous pachymeningitis sequelae in 2 patients, and aneurysm with compression on cavernous sinus in 1 patient. Three patients had normal MRI findings. The incidence of radiologically proven diagnosis of THS among the patients with the clinical findings suggesting THS seemed to be low in our study. In conclusion, MRI is the most valuable imaging technique to distinguish THS from other THS-like entities, and permits a precise assessment, management, and therapeutic planning of the underlying pathological conditions. (orig.)

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... six weeks) before being safe for MRI examinations. Examples include but are not limited to: artificial heart ... the area to be imaged. Furthermore, the examination takes longer than other imaging modalities (typically x-ray ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Most MRI exams are painless. However, some patients find it uncomfortable to remain still during MR imaging. ... anxious, confused or in severe pain, you may find it difficult to lie still during imaging. A ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... by the interpreting radiologist. Frequently, the differentiation of abnormal (diseased) tissue from normal tissues is better with ... Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are clearer and more detailed than other imaging methods. This exam does not use ionizing radiation and ... clearer and more detailed than with other imaging methods. This detail makes MRI an invaluable tool in ...

  3. CT and MRI imaging of the brain in MELAS syndrome.

    Science.gov (United States)

    Pauli, Wojciech; Zarzycki, Artur; Krzyształowski, Adam; Walecka, Anna

    2013-07-01

    MELAS syndrome (mitochondrial myopathy, encephalopathy, lactic acidosis, stroke-like episodes) is a rare, multisystem disorder which belongs to a group of mitochondrial metabolic diseases. As other diseases in this group, it is inherited in the maternal line. In this report, we discussed a case of a 10-year-old girl with clinical and radiological picture of MELAS syndrome. We would like to describe characteristic radiological features of MELAS syndrome in CT, MRI and MR spectroscopy of the brain and differential diagnosis. The rarity of this disorder and the complexity of its clinical presentation make MELAS patients among the most difficult to diagnose. Brain imaging studies require a wide differential diagnosis, primarily to distinguish between MELAS and ischemic stroke. Particularly helpful are the MRI and MR spectroscopy techniques.

  4. CT and MRI imaging of the brain in MELAS syndrome

    International Nuclear Information System (INIS)

    Pauli, Wojciech; Zarzycki, Artur; Krzyształowski, Adam; Walecka, Anna

    2013-01-01

    MELAS syndrome (mitochondrial myopathy, encephalopathy, lactic acidosis, stroke-like episodes) is a rare, multisystem disorder which belongs to a group of mitochondrial metabolic diseases. As other diseases in this group, it is inherited in the maternal line. In this report, we discussed a case of a 10-year-old girl with clinical and radiological picture of MELAS syndrome. We would like to describe characteristic radiological features of MELAS syndrome in CT, MRI and MR spectroscopy of the brain and differential diagnosis. The rarity of this disorder and the complexity of its clinical presentation make MELAS patients among the most difficult to diagnose. Brain imaging studies require a wide differential diagnosis, primarily to distinguish between MELAS and ischemic stroke. Particularly helpful are the MRI and MR spectroscopy techniques

  5. Clinical Evaluation of Stereotactic Target Localization Using 3-Tesla MRI for Radiosurgery Planning

    International Nuclear Information System (INIS)

    MacFadden, Derek; Zhang Beibei; Brock, Kristy K.; Hodaie, Mojgan; Laperriere, Normand; Schwartz, Michael; Tsao, May; Stainsby, Jeffrey; Lockwood, Gina; Mikulis, David; Menard, Cynthia

    2010-01-01

    Purpose: Increasing the magnetic resonance imaging (MRI) field strength can improve image resolution and quality, but concerns remain regarding the influence on geometric fidelity. The objectives of the present study were to spatially investigate the effect of 3-Tesla (3T) MRI on clinical target localization for stereotactic radiosurgery. Methods and Materials: A total of 39 patients were enrolled in a research ethics board-approved prospective clinical trial. Imaging (1.5T and 3T MRI and computed tomography) was performed after stereotactic frame placement. Stereotactic target localization at 1.5T vs. 3T was retrospectively analyzed in a representative cohort of patients with tumor (n = 4) and functional (n = 5) radiosurgical targets. The spatial congruency of the tumor gross target volumes was determined by the mean discrepancy between the average gross target volume surfaces at 1.5T and 3T. Reproducibility was assessed by the displacement from an averaged surface and volume congruency. Spatial congruency and the reproducibility of functional radiosurgical targets was determined by comparing the mean and standard deviation of the isocenter coordinates. Results: Overall, the mean absolute discrepancy across all patients was 0.67 mm (95% confidence interval, 0.51-0.83), significantly .4), and the gross target volume surface mean displacements were similar within and between users. The overall average isocenter coordinate discrepancy for the functional targets at 1.5T and 3T was 0.33 mm (95% confidence interval, 0.20-0.48), with no patient-specific differences between the mean values (p >.2) or standard deviations (p >.1). Conclusion: Our results have provided clinically relevant evidence supporting the spatial validity of 3T MRI for use in stereotactic radiosurgery under the imaging conditions used.

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... other imaging methods. This exam does not use ionizing radiation and may require an injection of a contrast ... other internal body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians to ...

  7. Negative MRI findings in a case of degenerative myelopathy in a dog : clinical communication

    Directory of Open Access Journals (Sweden)

    M. Okada

    2009-05-01

    Full Text Available An 11-year-old male Rough collie was submitted with paraparesis, but did not respond to medical treatment. Clinical signs worsened and the dog displayed paralysis, inability to stand and loss of voluntary bladder control, whereupon magnetic resonance imaging (MRI was performed. No significant abnormalities were identified from MRI, blood tests, cerebrospinal fluid tests or radiography. After MRI, the dog developed dyspnoea and died. Autopsy and subsequent histopathological examination led to a diagnosis of degenerative myelopathy.

  8. High-resolution whole-brain DCE-MRI using constrained reconstruction: Prospective clinical evaluation in brain tumor patients

    International Nuclear Information System (INIS)

    Guo, Yi; Zhu, Yinghua; Lingala, Sajan Goud; Nayak, Krishna; Lebel, R. Marc; Shiroishi, Mark S.; Law, Meng

    2016-01-01

    Purpose: To clinically evaluate a highly accelerated T1-weighted dynamic contrast-enhanced (DCE) MRI technique that provides high spatial resolution and whole-brain coverage via undersampling and constrained reconstruction with multiple sparsity constraints. Methods: Conventional (rate-2 SENSE) and experimental DCE-MRI (rate-30) scans were performed 20 minutes apart in 15 brain tumor patients. The conventional clinical DCE-MRI had voxel dimensions 0.9 × 1.3 × 7.0 mm 3 , FOV 22 × 22 × 4.2 cm 3 , and the experimental DCE-MRI had voxel dimensions 0.9 × 0.9 × 1.9 mm 3 , and broader coverage 22 × 22 × 19 cm 3 . Temporal resolution was 5 s for both protocols. Time-resolved images and blood–brain barrier permeability maps were qualitatively evaluated by two radiologists. Results: The experimental DCE-MRI scans showed no loss of qualitative information in any of the cases, while achieving substantially higher spatial resolution and whole-brain spatial coverage. Average qualitative scores (from 0 to 3) were 2.1 for the experimental scans and 1.1 for the conventional clinical scans. Conclusions: The proposed DCE-MRI approach provides clinically superior image quality with higher spatial resolution and coverage than currently available approaches. These advantages may allow comprehensive permeability mapping in the brain, which is especially valuable in the setting of large lesions or multiple lesions spread throughout the brain.

  9. MRI quality assurance using the ACR phantom in a multi-unit imaging center

    International Nuclear Information System (INIS)

    Ihalainen, Toni M.; Kuusela, Linda J.; Savolainen, Sauli E.; Loennroth, Nadja T.; Peltonen, Juha I.; Uusi-Simola, Jouni K.; Timonen, Marjut H.; Sipilae, Outi E.

    2011-01-01

    Background. Magnetic resonance imaging (MRI) instrumentation is vulnerable to technical and image quality problems, and quality assurance is essential. In the studied regional imaging center the long-term quality assurance has been based on MagNET phantom measurements. American College of Radiology (ACR) has an accreditation program including a standardized image quality measurement protocol and phantom. The ACR protocol includes recommended acceptance criteria for clinical sequences and thus provides possibility to assess the clinical relevance of quality assurance. The purpose of this study was to test the ACR MRI phantom in quality assurance of a multi-unit imaging center. Material and methods. The imaging center operates 11 MRI systems of three major manufacturers with field strengths of 3.0 T, 1.5 T and 1.0 T. Images of the ACR phantom were acquired using a head coil following the ACR scanning instructions. Both ACR T1- and T2-weighted sequences as well as T1- and T2-weighted brain sequences in clinical use at each site were acquired. Measurements were performed twice. The images were analyzed and the results were compared with the ACR acceptance levels. Results. The acquisition procedure with the ACR phantom was faster than with the MagNET phantoms. On the first and second measurement rounds 91% and 73% of the systems passed the ACR test. Measured slice thickness accuracies were not within the acceptance limits in site T2 sequences. Differences in the high contrast spatial resolution between the ACR and the site sequences were observed. In 3.0 T systems the image intensity uniformity was slightly lower than the ACR acceptance limit. Conclusion. The ACR method was feasible in quality assurance of a multi-unit imaging center and the ACR protocol could replace the MagNET phantom tests. An automatic analysis of the images will further improve cost-effectiveness and objectiveness of the ACR protocol

  10. Implementing MRI-based target delineation for cervical cancer treatment within a rapid workflow environment for image-guided brachytherapy: A practical approach for centers without in-room MRI.

    Science.gov (United States)

    Trifiletti, Daniel M; Libby, Bruce; Feuerlein, Sebastian; Kim, Taeho; Garda, Allison; Watkins, W Tyler; Erickson, Sarah; Ornan, Afshan; Showalter, Timothy N

    2015-01-01

    Magnetic resonance imaging (MRI)-based intracavitary brachytherapy offers several advantages over computed tomography (CT)-based brachytherapy, but many centers are unable to offer it at the time of brachytherapy because of logistic and/or financial considerations. We have implemented a method of integrating MRI into a CT-guided, high-dose-rate intracavitary brachytherapy workflow in clinics that do not have immediately available MRI capability. At our institution, patients receiving high-dose-rate intracavitary brachytherapy as a component of the definitive treatment of cervical cancer have a Smit sleeve placed during the first brachytherapy fraction in a dedicated suite with in-room CT-on-rails. After the first fraction of brachytherapy, an MRI is obtained with the Smit sleeve, but no applicator, in place. For each subsequent fraction, CT scans are coregistered to the MRI scan by the Smit sleeve. The gross target volume is defined by MRI and overlaid on the CT images for each brachytherapy treatment for dose optimization. This MRI-integrated workflow adds workflow is a feasible compromise to preserve an efficient workflow while integrating MRI target delineation, and it provides many of the advantages of both MRI- and CT-based brachytherapy. The future collection and analysis of clinical data will serve to compare the proposed approach to non-MRI containing techniques. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  11. Contribution of brain imaging techniques: CT-scan and magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Pasco-Papon, A.; Gourdier, A.L.; Papon, X.; Caron-Poitreau, C.

    1996-01-01

    In light of the current lack of consensus on the benefit of carotid artery surgery to treat asymptomatic carotid artery stenosis, the decision to operate on a patient depends on individual evaluation and characterization of risk factors on carotid artery stenosis greater than 70 %. The assessment of such risk factors is based especially on non-invasive brain imaging techniques.Computed tomography scanning (CT-scan) and magnetic resonance imaging (MRI) enable two types of stenosis to be differentiated, i.e. stenoses which are symptomatic and those that are radiologically proven versus those which are clinically and radiologically silent. CT-scan investigation (with and without injection of iodinated contrast media) still continues to be a common routine test in 1996 whenever a surgical revascularization procedure is planned. The presence of deep lacunar infarcts ipsilateral to the carotid artery stenosis generally evidence the reality of stenosis and thus are useful to the surgeon in establishing whether surgery is indicated. In the absence a consensus on indications for surgical management, the surgeon could use the CT-scan and MRI as medicolegal records which could be compared to a subsequent postoperative CT-scan in case of ischemic complications associated with the surgical procedure. Furthermore, recent cerebral ischemia as evidenced by filling with contrast material, will call for postponing treatment by a few weeks. Although conventional MRI is more contributive than brain CT-scan in terms of sensibility and specificity, its indications are narrower because of its limited availability and cost constraints. But, development of angio-MRI and functional imaging promise that its future is assured and even perhaps as the sole diagnostic method if its indications are expanded to include preoperative angiographic evaluation of atheromatous lesions of supra-aortic trunks. (authors). 37 refs

  12. PET/MRI in Oncological Imaging: State of the Art

    Science.gov (United States)

    Bashir, Usman; Mallia, Andrew; Stirling, James; Joemon, John; MacKewn, Jane; Charles-Edwards, Geoff; Goh, Vicky; Cook, Gary J.

    2015-01-01

    Positron emission tomography (PET) combined with magnetic resonance imaging (MRI) is a hybrid technology which has recently gained interest as a potential cancer imaging tool. Compared with CT, MRI is advantageous due to its lack of ionizing radiation, superior soft-tissue contrast resolution, and wider range of acquisition sequences. Several studies have shown PET/MRI to be equivalent to PET/CT in most oncological applications, possibly superior in certain body parts, e.g., head and neck, pelvis, and in certain situations, e.g., cancer recurrence. This review will update the readers on recent advances in PET/MRI technology and review key literature, while highlighting the strengths and weaknesses of PET/MRI in cancer imaging. PMID:26854157

  13. PET/MRI in Oncological Imaging: State of the Art

    Directory of Open Access Journals (Sweden)

    Usman Bashir

    2015-07-01

    Full Text Available Positron emission tomography (PET combined with magnetic resonance imaging (MRI is a hybrid technology which has recently gained interest as a potential cancer imaging tool. Compared with CT, MRI is advantageous due to its lack of ionizing radiation, superior soft-tissue contrast resolution, and wider range of acquisition sequences. Several studies have shown PET/MRI to be equivalent to PET/CT in most oncological applications, possibly superior in certain body parts, e.g., head and neck, pelvis, and in certain situations, e.g., cancer recurrence. This review will update the readers on recent advances in PET/MRI technology and review key literature, while highlighting the strengths and weaknesses of PET/MRI in cancer imaging.

  14. Edge-oriented dual-dictionary guided enrichment (EDGE) for MRI-CT image reconstruction.

    Science.gov (United States)

    Li, Liang; Wang, Bigong; Wang, Ge

    2016-01-01

    In this paper, we formulate the joint/simultaneous X-ray CT and MRI image reconstruction. In particular, a novel algorithm is proposed for MRI image reconstruction from highly under-sampled MRI data and CT images. It consists of two steps. First, a training dataset is generated from a series of well-registered MRI and CT images on the same patients. Then, an initial MRI image of a patient can be reconstructed via edge-oriented dual-dictionary guided enrichment (EDGE) based on the training dataset and a CT image of the patient. Second, an MRI image is reconstructed using the dictionary learning (DL) algorithm from highly under-sampled k-space data and the initial MRI image. Our algorithm can establish a one-to-one correspondence between the two imaging modalities, and obtain a good initial MRI estimation. Both noise-free and noisy simulation studies were performed to evaluate and validate the proposed algorithm. The results with different under-sampling factors show that the proposed algorithm performed significantly better than those reconstructed using the DL algorithm from MRI data alone.

  15. Magnetic resonance imaging for clinical management of rectal cancer

    DEFF Research Database (Denmark)

    Beets-Tan, Regina G H; Lambregts, Doenja M J; Maas, Monique

    2018-01-01

    OBJECTIVES: To update the 2012 ESGAR consensus guidelines on the acquisition, interpretation and reporting of magnetic resonance imaging (MRI) for clinical staging and restaging of rectal cancer. METHODS: Fourteen abdominal imaging experts from the European Society of Gastrointestinal and Abdomin...

  16. MRI in temporal lobe epilepsy. Correlation between EEG, SPECT and clinical features

    International Nuclear Information System (INIS)

    Uesugi, Hideji; Onuma, Teiichi; Matsuda, Hiroshi; Ishida, Shiro

    1996-01-01

    The relationship between MRI, SPECT, EEG and clinical features in temporal lobe epilepsy was investigated. Subjects were 162 patients (84 males, 78 females) whose average age was 38.1±12.1 years. SPECT was carried out in 45 patients. The results were as follows: abnormal MR images were obtained in 36% of the group without epileptic discharge, and in 42% of the group with temporal spikes. There was no correlation between epileptic discharge in EEG and MRI abnormality. The lateralities of epileptic discharge and MRI were in disagreement in 9 of 39 patients (23%), indicating that determining the epileptic focus from scalp EEG was difficult. There was no correlation between the basic activity in EEG and abnormality in MRI. The rate of abnormal SPECT (89%) was higher than that of abnormal MRI (40%). The rate of the group with ictal automatism (52%) was higher than that of the group without ictal automatism (35%). The rate of abnormal MR images was high in the group with encephalitis (73%). The rate was higher in the group with febrile convulsion (62%) than in the group without it (28%). The rate of the abnormal MR images was higher in the group with a seizure frequency of at least several mal/month (48%) than in the group with a seizure frequency of less than several mal/year (29%). (author)

  17. Clinical neuroanatomy - cranial MRI and CT. 4. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Lanfermann, Heinrich; Raab, Peter; Kretschmann, Hans-Joachim; Weinrich, Wolfgang

    2015-01-01

    The book on clinical neuroanatomy - cranial MRI and CT covers the following issues: layered imaging diagnostics and reference structures; frontal layer, sagittal layers, transverse layers, brainstem, skull topography and the intracranial spaces and structures, facial skull topography, head-neck topography; neurofunctional systems, neurotransmitter and neuromodulators, surveillance material and techniques.

  18. Clinical use of gadobutrol for contrast-enhanced magnetic resonance imaging of neurological diseases

    Directory of Open Access Journals (Sweden)

    Cheng KT

    2012-02-01

    Full Text Available Kenneth T Cheng1, Hannah Y Cheng2, Kam Leung31Department of Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD, USA; 2Freelance Technical Writer, New Orleans, LA, USA; 3National Center for Biotechnology Information, National Library of Medicine, National Institutes of Health, Bethesda, MD, USAAbstract: Contrast-enhanced magnetic resonance imaging (CE-MRI is an important clinical tool for diagnosing neurological diseases. The appropriate use of a suitable MRI contrast agent or contrast pharmaceutical is essential for CE-MRI to produce desirable diagnostic images. Currently, there are seven contrast agents (CAs or pharmaceuticals approved for clinical imaging of the central nervous system (CNS in the US, Europe, or Japan. All of the clinically approved CAs are water-soluble gadolinium-based contrast agents (GBCAs which do not penetrate the CNS blood–brain barrier (BBB. These agents are used for imaging CNS areas without a BBB, or various pathologies, such as tumors and infection that break down the BBB and allow CAs to enter into the surrounding parenchyma. Clinically, GBCAs are most useful for detecting primary and secondary cerebral neoplastic lesions. Among these CNS GBCAs, gadobutrol (Gd-BT-DO3A, Gadovist™ is a neutral, nonionic, macrocyclic compound that showed promising results from clinical trials of CNS imaging. In comparison with other GBCAs, Gd-BT-DO3A has relatively high in vitro kinetic stability and r1 relaxivity. Gd-BT-DO3A has been recently approved by the US Food and Drug Administration (FDA in 2011 for CNS imaging. A review of available literature shows that Gd-BT-DO3A exhibits similar safety and clinical efficacy profiles to other GBCAs. Gd-BT-DO3A has the distinguishing feature that it is the only clinical agent commercially available in a formulation of 1.0 M concentration with a relatively higher in vitro T1 shortening per unit volume than other clinical GBCAs which are only

  19. An audit of clinical practice, referral patterns, and appropriateness of clinical indications for brain MRI examinations: A single-centre study in Ghana.

    Science.gov (United States)

    Piersson, A D; Nunoo, G; Gorleku, P N

    2018-05-01

    The aim of this study was to investigate current brain MRI practice, pattern of brain MRI requests, and their appropriateness using the American College of Radiology (ACR) Appropriateness Criteria. We used direct observation and questionnaires to obtain data concerning routine brain MRI practice. We then retrospectively analyzed (i) demographic characteristics, (ii) clinical history, and (iii) appropriateness of brain MRI requests against published criteria. All patients were administered the screening questionnaire; however, no reviews were undertaken directly with patients, and no signature of the radiographer was recorded. Apart from routine brain protocol, there were dedicated protocols for epilepsy and stroke. Brain MRI images from 161 patients (85 Males; 76 Females) were analyzed. The age group with most brain MRI requests were from 26 to 45 year olds. The commonest four clinical indications for imaging were brain tumour, headache, seizure, and stroke. Using the ACR Appropriateness Criteria, almost 43% of the brain MRI scans analyzed were found to be "usually appropriate", 38% were "maybe appropriate" and 19% were categorized as "usually not appropriate". There was knowledge gap with regards to MRI safety in local practice, thus there is the utmost need for MRI safety training. Data on the commonest indications for performing brain MRI in this study should be used to inform local neuroradiological practice. Dedicated stroke and epilepsy MRI protocols require additional sequences i.e. MRA and 3D T1 volume acquisition, respectively. The ACR Appropriateness Criteria is recommended for use by the referring practitioners to improve appropriateness of brain MRI requests. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  20. Respiratory motion-resolved, self-gated 4D-MRI using Rotating Cartesian K-space (ROCK): Initial clinical experience on an MRI-guided radiotherapy system.

    Science.gov (United States)

    Han, Fei; Zhou, Ziwu; Du, Dongsu; Gao, Yu; Rashid, Shams; Cao, Minsong; Shaverdian, Narek; Hegde, John V; Steinberg, Michael; Lee, Percy; Raldow, Ann; Low, Daniel A; Sheng, Ke; Yang, Yingli; Hu, Peng

    2018-06-01

    To optimize and evaluate the respiratory motion-resolved, self-gated 4D-MRI using Rotating Cartesian K-space (ROCK-4D-MRI) method in a 0.35 T MRI-guided radiotherapy (MRgRT) system. The study included seven patients with abdominal tumors treated on the MRgRT system. ROCK-4D-MRI and 2D-CINE, was performed immediately after one of the treatment fractions. Motion quantification based on 4D-MRI was compared with those based on 2D-CINE. The image quality of 4D-MRI was evaluated against 4D-CT. The gross tumor volumes (GTV) were defined based on individual respiratory phases of both 4D-MRI and 4D-CT and compared for their variability over the respiratory cycle. The motion measurements based on 4D-MRI matched well with 2D-CINE, with differences of 1.04 ± 0.52 mm in the superior-inferior and 0.54 ± 0.21 mm in the anterior-posterior directions. The image quality scores of 4D-MRI were significantly higher than 4D-CT, with better tumor contrast (3.29 ± 0.76 vs. 1.86 ± 0.90) and less motion artifacts (3.57 ± 0.53 vs. 2.29 ± 0.95). The GTVs were more consistent in 4D-MRI than in 4D-CT, with significantly smaller GTV variability (9.31 ± 4.58% vs. 34.27 ± 23.33%). Our study demonstrated the clinical feasibility of using the ROCK-4D-MRI to acquire high quality, respiratory motion-resolved 4D-MRI in a low-field MRgRT system. The 4D-MRI image could provide accurate dynamic information for radiotherapy treatment planning. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. All-in-one interictal presurgical imaging in patients with epilepsy: single-session EEG/PET/(f)MRI

    Energy Technology Data Exchange (ETDEWEB)

    Grouiller, Frederic; Delattre, Benedicte M.A.; Lazeyras, Francois; Ratib, Osman; Vargas, Maria I.; Garibotto, Valentina [Geneva University Hospital, Department of Radiology and Medical Informatics, Geneva 14 (Switzerland); Pittau, Francesca; Spinelli, Laurent; Seeck, Margitta; Vulliemoz, Serge [Geneva University Hospital, EEG and Epilepsy Unit, Department of Neurology, Geneva 14 (Switzerland); Heinzer, Susanne [Philips AG Healthcare, Zuerich (Switzerland); Iannotti, Giannina R. [Geneva University Hospital, Functional Brain Mapping Laboratory, Department of Fundamental Neurosciences, Geneva 14 (Switzerland)

    2015-04-17

    In patients with pharmacoresistant focal epilepsy, resection of the epileptic focus can lead to freedom from seizures or significant improvement in well-selected candidates. Localization of the epileptic focus with multimodal concordance is crucial for a good postoperative outcome. Beyond the detection of epileptogenic lesions on structural MRI and focal hypometabolism on FDG PET, EEG-based Electric Source Imaging (ESI) and simultaneous EEG and functional MRI (EEG-fMRI) are increasingly applied for mapping epileptic activity. We here report presurgical multimodal interictal imaging using a hybrid PET/MR scanner for single-session FDG PET, MRI, EEG-fMRI and ESI. This quadrimodal imaging procedure was performed in a single session in 12 patients using a high-density (256 electrodes) MR-compatible EEG system and a hybrid PET/MR scanner. EEG was used to exclude subclinical seizures during uptake of the PET tracer, to compute ESI on interictal epileptiform discharges and to guide fMRI analysis for mapping haemodynamic changes correlated with interictal epileptiform activity. The whole multimodal recording was performed in less than 2 hours with good patient comfort and data quality. Clinically contributory examinations with at least two modalities were obtained in nine patients and with all modalities in five patients. This single-session quadrimodal imaging procedure provided reliable and contributory interictal clinical data. This procedure avoids multiple scanning sessions and is associated with less radiation exposure than PET-CT. Moreover, it guarantees the same medication level and medical condition for all modalities. The procedure improves workflow and could reduce the duration and cost of presurgical epilepsy evaluations. (orig.)

  2. All-in-one interictal presurgical imaging in patients with epilepsy: single-session EEG/PET/(f)MRI

    International Nuclear Information System (INIS)

    Grouiller, Frederic; Delattre, Benedicte M.A.; Lazeyras, Francois; Ratib, Osman; Vargas, Maria I.; Garibotto, Valentina; Pittau, Francesca; Spinelli, Laurent; Seeck, Margitta; Vulliemoz, Serge; Heinzer, Susanne; Iannotti, Giannina R.

    2015-01-01

    In patients with pharmacoresistant focal epilepsy, resection of the epileptic focus can lead to freedom from seizures or significant improvement in well-selected candidates. Localization of the epileptic focus with multimodal concordance is crucial for a good postoperative outcome. Beyond the detection of epileptogenic lesions on structural MRI and focal hypometabolism on FDG PET, EEG-based Electric Source Imaging (ESI) and simultaneous EEG and functional MRI (EEG-fMRI) are increasingly applied for mapping epileptic activity. We here report presurgical multimodal interictal imaging using a hybrid PET/MR scanner for single-session FDG PET, MRI, EEG-fMRI and ESI. This quadrimodal imaging procedure was performed in a single session in 12 patients using a high-density (256 electrodes) MR-compatible EEG system and a hybrid PET/MR scanner. EEG was used to exclude subclinical seizures during uptake of the PET tracer, to compute ESI on interictal epileptiform discharges and to guide fMRI analysis for mapping haemodynamic changes correlated with interictal epileptiform activity. The whole multimodal recording was performed in less than 2 hours with good patient comfort and data quality. Clinically contributory examinations with at least two modalities were obtained in nine patients and with all modalities in five patients. This single-session quadrimodal imaging procedure provided reliable and contributory interictal clinical data. This procedure avoids multiple scanning sessions and is associated with less radiation exposure than PET-CT. Moreover, it guarantees the same medication level and medical condition for all modalities. The procedure improves workflow and could reduce the duration and cost of presurgical epilepsy evaluations. (orig.)

  3. Understanding Magnetic Resonance Imaging of Knee Cartilage Repair: A Focus on Clinical Relevance.

    Science.gov (United States)

    Hayashi, Daichi; Li, Xinning; Murakami, Akira M; Roemer, Frank W; Trattnig, Siegfried; Guermazi, Ali

    2017-06-01

    The aims of this review article are (a) to describe the principles of morphologic and compositional magnetic resonance imaging (MRI) techniques relevant for the imaging of knee cartilage repair surgery and their application to longitudinal studies and (b) to illustrate the clinical relevance of pre- and postsurgical MRI with correlation to intraoperative images. First, MRI sequences that can be applied for imaging of cartilage repair tissue in the knee are described, focusing on comparison of 2D and 3D fast spin echo and gradient recalled echo sequences. Imaging features of cartilage repair tissue are then discussed, including conventional (morphologic) MRI and compositional MRI techniques. More specifically, imaging techniques for specific cartilage repair surgery techniques as described above, as well as MRI-based semiquantitative scoring systems for the knee cartilage repair tissue-MR Observation of Cartilage Repair Tissue and Cartilage Repair OA Knee Score-are explained. Then, currently available surgical techniques are reviewed, including marrow stimulation, osteochondral autograft, osteochondral allograft, particulate cartilage allograft, autologous chondrocyte implantation, and others. Finally, ongoing research efforts and future direction of cartilage repair tissue imaging are discussed.

  4. Avoiding preoperative breast MRI when conventional imaging is sufficient to stage patients eligible for breast conserving therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pengel, Kenneth E., E-mail: k.pengel@nki.nl [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Loo, Claudette E. [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Wesseling, Jelle [Department of Pathology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Pijnappel, Ruud M. [Department of Radiology/Image Sciences Institute, University Medical Center Utrecht Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Rutgers, Emiel J.Th. [Department of Surgical Oncology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Gilhuijs, Kenneth G.A. [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Radiology/Image Sciences Institute, University Medical Center Utrecht Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2014-02-15

    Aim: To determine when preoperative breast MRI will not be more informative than available breast imaging and can be omitted in patients eligible for breast conserving therapy (BCT). Methods: We performed an MRI in 685 consecutive patients with 692 invasive breast tumors and eligible for BCT based on conventional imaging and clinical examination. We explored associations between patient, tumor, and conventional imaging characteristics and similarity with MRI findings. Receiver operating characteristic (ROC) analysis was employed to compute the area under the curve (AUC). Results: MRI and conventional breast imaging were similar in 585 of the 692 tumors (85%). At univariate analysis, age (p < 0.001), negative preoperative lymph node status (p = 0.011), comparable tumor diameter at mammography and at ultrasound (p = 0.001), negative HER2 status (p = 0.044), and absence of invasive lobular cancer (p = 0.005) were significantly associated with this similarity. At multivariate analysis, these factors, except HER2 status, retained significant associations. The AUC was 0.68. Conclusions: It is feasible to identify a subgroup of patients prior to preoperative breast MRI, who will most likely show similar results on conventional imaging as on MRI. These findings enable formulation of a practical consensus guideline to determine in which patients a preoperative breast MRI can be omitted.

  5. Avoiding preoperative breast MRI when conventional imaging is sufficient to stage patients eligible for breast conserving therapy

    International Nuclear Information System (INIS)

    Pengel, Kenneth E.; Loo, Claudette E.; Wesseling, Jelle; Pijnappel, Ruud M.; Rutgers, Emiel J.Th.; Gilhuijs, Kenneth G.A.

    2014-01-01

    Aim: To determine when preoperative breast MRI will not be more informative than available breast imaging and can be omitted in patients eligible for breast conserving therapy (BCT). Methods: We performed an MRI in 685 consecutive patients with 692 invasive breast tumors and eligible for BCT based on conventional imaging and clinical examination. We explored associations between patient, tumor, and conventional imaging characteristics and similarity with MRI findings. Receiver operating characteristic (ROC) analysis was employed to compute the area under the curve (AUC). Results: MRI and conventional breast imaging were similar in 585 of the 692 tumors (85%). At univariate analysis, age (p < 0.001), negative preoperative lymph node status (p = 0.011), comparable tumor diameter at mammography and at ultrasound (p = 0.001), negative HER2 status (p = 0.044), and absence of invasive lobular cancer (p = 0.005) were significantly associated with this similarity. At multivariate analysis, these factors, except HER2 status, retained significant associations. The AUC was 0.68. Conclusions: It is feasible to identify a subgroup of patients prior to preoperative breast MRI, who will most likely show similar results on conventional imaging as on MRI. These findings enable formulation of a practical consensus guideline to determine in which patients a preoperative breast MRI can be omitted

  6. Clinical experience with MRI in head trauma cases

    International Nuclear Information System (INIS)

    Yamagami, Tatsuhito; Goto, Yasunobu; Kinuta, Yuji; Tashiro, Yuzuru; Nishihara, Kiyoshi; Hashimoto, Kenji; Minamikawa, Jun; Kikuchi, Haruhiko; Imataka, Kiyoharu.

    1988-01-01

    The ability to identify lesions after head trauma using magnetic resonance imaging (MRI) was tested in 199 cases. A resistive-type MRI scanner operating at a field of 0.2 Tesla was utilized in inversion-recovery (IR) and saturation-recovery (SR) radiofrequency-pulse sequences. Of the total number of cases, 54 were examined within 4 days after injury. An intracranial hematoma was removed in 47 cases. The MRI findings were normal in the cases of cerebral concussion, even in the presence of skull fracture. High intensity areas were seen in the SR images in 12 cases which were normal on X-ray CT. Both acute and subacute non-hemorrhagic contusion sites were visible as low intensity areas on the T 1 -weighted images and as high intensity areas on the SR images. Acute hemorrhagic contusion sites were visible as isointense and low intensity areas in the T 1 -weighted images and as high intensity areas in the SR images. Subacute sites appeared as high intensity areas in the T 1 -weighted, SR, and T 2 -weighted images. Direct coronal and sagittal views were adequate for the recognition of the three-dimensional brain structure. MRI was useful in the identification of brain contusion, in postoperative follow-ups, and in the detection of complications in the chronic stage. In the follow-up of 48 brain contusion cases, 13 cases showed normalized MRI findings and 9 cases showed improved findings. The recovery of cerebral function in these cases was good. The lesions demonstrated by MRI were considered to be contusional hematoma, petechiae, brain edema, shear injury, and non-hemorrhagic contusion. When they persist, such lesions are thought to change into such conditions as scar, gliosis, porencephaly, and brain atrophy. (author)

  7. Clinical utility and limitation of MRI in neuroradiology

    International Nuclear Information System (INIS)

    Aoki, Shigeki; Machida, Tohru; Shirouzu, Ichirou; Ohkubo, Toshiyuki; Sasaki, Yasushi.

    1992-01-01

    Magnetic resonance imaging (MRI) has several advantages over computed tomography in the neuroradiological field: it provids biochemical information, images in any plane without bone artifacts, and superior contrast between gray matter and white matter. It is, however, of limited availability because of longer imaging time, poor spatial resolution, and poor visualization of calcification and the bone. In this review, pathophysiology that shows relatively characteristic signal intensity is described, including hemorrhage, fat, protein-rich cyst, calcification, iron, and posterior pituitary gland. The utility and limitation of MRI are discussed in terms of the following diseases and lesion sites: small tumors in the skull base; demyelination of white matter or degenerative disease; cerebral infarction or cerebral ischemic disease; intramedullary lesion; meningeal lesion; and pediatric diseases such as medullary sheath formation and malformation. Finally, recent advance and future perspectives of MRI are presented, focusing on 3-dimensional imaging, MR angiography, fat-suppression MR imaging, MR spectroscopy, intravoxel incoherent motion imaging, imaging time, and spatial resolution. (N.K.) 82 refs

  8. MRI of the SI joints commonly shows non-inflammatory disease in patients clinically suspected of sacroiliitis

    Energy Technology Data Exchange (ETDEWEB)

    Jans, L., E-mail: lennartjans@hotmail.com [Department of Radiology and Medical Imaging, Ghent University Hospital, De Pintelaan 185, 9000 Gent (Belgium); Van Praet, L.; Elewaut, D.; Van den Bosch, F.; Carron, P. [Department of Rheumatology, Ghent University Hospital, De Pintelaan 185, 9000 Gent (Belgium); Jaremko, J.L. [Department of Radiology, University of Alberta Hospital, 8440-112 Street, Edmonton T6G 2B7, Alberta (Canada); Behaeghe, M.; Denis, A.; Huysse, W.; Lambrecht, V.; Verstraete, K. [Department of Radiology and Medical Imaging, Ghent University Hospital, De Pintelaan 185, 9000 Gent (Belgium)

    2014-01-15

    Purpose: To determine the prevalence of clinically relevant non-inflammatory disease on MRI of the sacroiliac (SI) joints in patients suspected of sacroiliitis. To assess the added value of axial imaging of the pelvis in these patients. Methods: In a retrospective study of 691 patients undergoing MRI of the SI joints from January 2006 to December 2012 for inflammatory back pain the prevalence of sacroiliitis and non-inflammatory disease was recorded. Results: In 285 (41%) patients MRI did not show any abnormal findings. In 36% of patients MRI features of sacroiliitis were present. Spinal degenerative changes were the most common non-inflammatory finding in 305 patients (44.1%) and consisted of disc degeneration in 222 (32%) patients, facet joint arthrosis in 58 (8.4%) patients and disc herniation in 25 (3.6%) patients. Hip joint disease in 44 (6.4%) patients, lumbosacral transitional anomaly in 41 (5.9%) patients, SI joint degenerative changes in 25 (3.6%) patients and diffuse idiopathic skeletal hyperostosis in 24 (3.5%) patients were also common. Osteitis condensans ilii in 17 (2.5%) patients, tumour in 11 (1.6%) patients, fracture in 8 (1.2%) patients, infection in 4 (0.6%) patients and acute spondylolysis in 2 patients (0.3%) were less frequently seen. Conclusion: Our study shows that non-inflammatory disease is more common than true sacroiliitis on MRI of the SI joints in patients with inflammatory type back pain. Axial pulse sequences may demonstrate unexpected findings that remain undetected if only coronal images are obtained. Clinical relevance statement:, MRI of the SI joints may demonstrate conditions that clinically mimic sacroiliitis. Axial imaging of the pelvis may help detect these unexpected findings.

  9. MRI of the SI joints commonly shows non-inflammatory disease in patients clinically suspected of sacroiliitis

    International Nuclear Information System (INIS)

    Jans, L.; Van Praet, L.; Elewaut, D.; Van den Bosch, F.; Carron, P.; Jaremko, J.L.; Behaeghe, M.; Denis, A.; Huysse, W.; Lambrecht, V.; Verstraete, K.

    2014-01-01

    Purpose: To determine the prevalence of clinically relevant non-inflammatory disease on MRI of the sacroiliac (SI) joints in patients suspected of sacroiliitis. To assess the added value of axial imaging of the pelvis in these patients. Methods: In a retrospective study of 691 patients undergoing MRI of the SI joints from January 2006 to December 2012 for inflammatory back pain the prevalence of sacroiliitis and non-inflammatory disease was recorded. Results: In 285 (41%) patients MRI did not show any abnormal findings. In 36% of patients MRI features of sacroiliitis were present. Spinal degenerative changes were the most common non-inflammatory finding in 305 patients (44.1%) and consisted of disc degeneration in 222 (32%) patients, facet joint arthrosis in 58 (8.4%) patients and disc herniation in 25 (3.6%) patients. Hip joint disease in 44 (6.4%) patients, lumbosacral transitional anomaly in 41 (5.9%) patients, SI joint degenerative changes in 25 (3.6%) patients and diffuse idiopathic skeletal hyperostosis in 24 (3.5%) patients were also common. Osteitis condensans ilii in 17 (2.5%) patients, tumour in 11 (1.6%) patients, fracture in 8 (1.2%) patients, infection in 4 (0.6%) patients and acute spondylolysis in 2 patients (0.3%) were less frequently seen. Conclusion: Our study shows that non-inflammatory disease is more common than true sacroiliitis on MRI of the SI joints in patients with inflammatory type back pain. Axial pulse sequences may demonstrate unexpected findings that remain undetected if only coronal images are obtained. Clinical relevance statement:, MRI of the SI joints may demonstrate conditions that clinically mimic sacroiliitis. Axial imaging of the pelvis may help detect these unexpected findings

  10. Content Based Medical Image Retrieval for Histopathological, CT and MRI Images

    Directory of Open Access Journals (Sweden)

    Swarnambiga AYYACHAMY

    2013-09-01

    Full Text Available A content based approach is followed for medical images. The purpose of this study is to access the stability of these methods for medical image retrieval. The methods used in color based retrieval for histopathological images are color co-occurrence matrix (CCM and histogram with meta features. For texture based retrieval GLCM (gray level co-occurrence matrix and local binary pattern (LBP were used. For shape based retrieval canny edge detection and otsu‘s method with multivariable threshold were used. Texture and shape based retrieval were implemented using MRI (magnetic resonance images. The most remarkable characteristics of the article are its content based approach for each medical imaging modality. Our efforts were focused on the initial visual search. From our experiment, histogram with meta features in color based retrieval for histopathological images shows a precision of 60 % and recall of 30 %. Whereas GLCM in texture based retrieval for MRI images shows a precision of 70 % and recall of 20 %. Shape based retrieval for MRI images shows a precision of 50% and recall of 25 %. The retrieval results shows that this simple approach is successful.

  11. Software-based PET-MR image coregistration: combined PET-MRI for the rest of us

    International Nuclear Information System (INIS)

    Robertson, Matthew S.; Liu, Xinyang; Vyas, Pranav K.; Safdar, Nabile M.; Plishker, William; Zaki, George F.; Shekhar, Raj

    2016-01-01

    With the introduction of hybrid positron emission tomography/magnetic resonance imaging (PET/MRI), a new imaging option to acquire multimodality images with complementary anatomical and functional information has become available. Compared with hybrid PET/computed tomography (CT), hybrid PET/MRI is capable of providing superior anatomical detail while removing the radiation exposure associated with CT. The early adoption of hybrid PET/MRI, however, has been limited. To provide a viable alternative to the hybrid PET/MRI hardware by validating a software-based solution for PET-MR image coregistration. A fully automated, graphics processing unit-accelerated 3-D deformable image registration technique was used to align PET (acquired as PET/CT) and MR image pairs of 17 patients (age range: 10 months-21 years, mean: 10 years) who underwent PET/CT and body MRI (chest, abdomen or pelvis), which were performed within a 28-day (mean: 10.5 days) interval. MRI data for most of these cases included single-station post-contrast axial T1-weighted images. Following registration, maximum standardized uptake value (SUV max ) values observed in coregistered PET (cPET) and the original PET were compared for 82 volumes of interest. In addition, we calculated the target registration error as a measure of the quality of image coregistration, and evaluated the algorithm's performance in the context of interexpert variability. The coregistration execution time averaged 97±45 s. The overall relative SUV max difference was 7% between cPET-MRI and PET/CT. The average target registration error was 10.7±6.6 mm, which compared favorably with the typical voxel size (diagonal distance) of 8.0 mm (typical resolution: 0.66 mm x 0.66 mm x 8 mm) for MRI and 6.1 mm (typical resolution: 3.65 mm x 3.65 mm x 3.27 mm) for PET. The variability in landmark identification did not show statistically significant differences between the algorithm and a typical expert. We have presented a software

  12. Software-based PET-MR image coregistration: combined PET-MRI for the rest of us

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Matthew S.; Liu, Xinyang; Vyas, Pranav K.; Safdar, Nabile M. [Children' s National Health System, Sheikh Zayed Institute for Pediatric Surgical Innovation, Washington, DC (United States); Plishker, William; Zaki, George F. [IGI Technologies, Inc., College Park, MD (United States); Shekhar, Raj [Children' s National Health System, Sheikh Zayed Institute for Pediatric Surgical Innovation, Washington, DC (United States); IGI Technologies, Inc., College Park, MD (United States)

    2016-10-15

    With the introduction of hybrid positron emission tomography/magnetic resonance imaging (PET/MRI), a new imaging option to acquire multimodality images with complementary anatomical and functional information has become available. Compared with hybrid PET/computed tomography (CT), hybrid PET/MRI is capable of providing superior anatomical detail while removing the radiation exposure associated with CT. The early adoption of hybrid PET/MRI, however, has been limited. To provide a viable alternative to the hybrid PET/MRI hardware by validating a software-based solution for PET-MR image coregistration. A fully automated, graphics processing unit-accelerated 3-D deformable image registration technique was used to align PET (acquired as PET/CT) and MR image pairs of 17 patients (age range: 10 months-21 years, mean: 10 years) who underwent PET/CT and body MRI (chest, abdomen or pelvis), which were performed within a 28-day (mean: 10.5 days) interval. MRI data for most of these cases included single-station post-contrast axial T1-weighted images. Following registration, maximum standardized uptake value (SUV{sub max}) values observed in coregistered PET (cPET) and the original PET were compared for 82 volumes of interest. In addition, we calculated the target registration error as a measure of the quality of image coregistration, and evaluated the algorithm's performance in the context of interexpert variability. The coregistration execution time averaged 97±45 s. The overall relative SUV{sub max} difference was 7% between cPET-MRI and PET/CT. The average target registration error was 10.7±6.6 mm, which compared favorably with the typical voxel size (diagonal distance) of 8.0 mm (typical resolution: 0.66 mm x 0.66 mm x 8 mm) for MRI and 6.1 mm (typical resolution: 3.65 mm x 3.65 mm x 3.27 mm) for PET. The variability in landmark identification did not show statistically significant differences between the algorithm and a typical expert. We have presented a software

  13. Imaging of female pelvic malignancies regarding MRI, CT, and PET/CT. Pt. 2

    International Nuclear Information System (INIS)

    Alt, Celine D.; Kauczor, Hans-Ulrich; Hallscheidt, Peter; Brocker, Kerstin A.; Eichbaum, Michael; Sohn, Christof; Arnegger, Florian U.

    2011-01-01

    To compose diagnostic standard operating procedures for both clinical and imaging assessment for vulvar and vaginal cancer, for vaginal sarcoma, and for ovarian cancer. The literature was reviewed for diagnosing the above mentioned malignancies in the female pelvis. Special focus herein lies in tumor representation in MRI, followed by the evaluation of CT and PET/CT for this topic. MRI is a useful additional diagnostic complement but by no means replaces established methods of gynecologic diagnostics and ultrasound. In fact, MRI is only implemented in the guidelines for vulvar cancer. According to the current literature, CT is still the cross-sectional imaging modality of choice for evaluating ovarian cancer. PET/CT appears to have advantages for staging and follow-up in sarcomas and cancers of the ovaries. (orig.)

  14. MRI: Imaging of stomach

    International Nuclear Information System (INIS)

    Lam, W. W. M; Lee, J. S. W.; Ho, G.

    2007-01-01

    Full text: The study is to determine the optimal MRI bowel preparation regime for visualization of the stomach anatomy, Eight healthy volunteers were asked to take water, 75% barium and blueberry juice. The image quality and tolerance of different stomach distension regime were evaluated. Blueberry juice gave the best distension, but the signal intensity was not very homogeneous. Taking into account the image quality, tolerability and adverse effects, it is concluded that water is the most desirable oral contrast for MR stomach imaging

  15. Non-invasive imaging of plant roots in different soils using magnetic resonance imaging (MRI

    Directory of Open Access Journals (Sweden)

    Daniel Pflugfelder

    2017-11-01

    Full Text Available Abstract Background Root systems are highly plastic and adapt according to their soil environment. Studying the particular influence of soils on root development necessitates the adaptation and evaluation of imaging methods for multiple substrates. Non-invasive 3D root images in soil can be obtained using magnetic resonance imaging (MRI. Not all substrates, however, are suitable for MRI. Using barley as a model plant we investigated the achievable image quality and the suitability for root phenotyping of six commercially available natural soil substrates of commonly occurring soil textures. The results are compared with two artificially composed substrates previously documented for MRI root imaging. Results In five out of the eight tested substrates, barley lateral roots with diameters below 300 µm could still be resolved. In two other soils, only the thicker barley seminal roots were detectable. For these two substrates the minimal detectable root diameter was between 400 and 500 µm. Only one soil did not allow imaging of the roots with MRI. In the artificially composed substrates, soil moisture above 70% of the maximal water holding capacity (WHCmax impeded root imaging. For the natural soil substrates, soil moisture had no effect on MRI root image quality in the investigated range of 50–80% WHCmax. Conclusions Almost all tested natural soil substrates allowed for root imaging using MRI. Half of these substrates resulted in root images comparable to our current lab standard substrate, allowing root detection down to a diameter of 300 µm. These soils were used as supplied by the vendor and, in particular, removal of ferromagnetic particles was not necessary. With the characterization of different soils, investigations such as trait stability across substrates are now possible using noninvasive MRI.

  16. Clinical and MRI features in pediatric multiple sclerosis

    International Nuclear Information System (INIS)

    Zhao Cailei; Xie Sheng; Xiao Jiangxi; Wang Shuang

    2011-01-01

    Objective: To investigate the clinical and MRI features of multiple sclerosis in children, including the clinically isolated syndrome (CIS) and relapse. Methods: In total, 16 cases of pediatric multiple sclerosis were included in this study. Of them, 11 patients were female and 5 were male, with the mean onset age of 10.1 years. They were followed up for 4 months to 7 years and found to have 1- 5 relapses. The clinical manifestations of CIS and relapse were analyzed by a pediatric neurologist. An experienced neuroradiologist reviewed the MRI images of CIS and relapse. Information on the location, size, and pattern of the lesions was gathered. The location of lesions included subcortical, central, and periventricular white matter, cortex, deep gray matter, brain stem, and cerebellum. Results: CIS episode presented acute onsets in 13/16 cases, with symptoms of cortices in 10 cases and visual impairment in 6 cases. Relapse occurred in 14/16 cases within one year. The incidence of symptoms of cortices was less frequent and severe in the second episode of MS, whereas the visual impairment had a high incidence. All patients had full recovery after the last episode. MRI of CIS showed confluent subcortical white matter lesions in 13/16 cases, abutting on central white matter lesions. The most frequently involved brain part was the frontal lobe, followed by the parietal lobe. Cortical involvement was observed in 9/16 cases. In 6 cases, periventricular white matter lesions were detected. Bilateral deep gray matter was abnormal in 4 cases. Other abnormalities included brain stem lesions in 5 cases, cerebellum lesions in 3 cases, optic nerve involvement in 3 cases, and pyramidal tract lesions in 2 cases. MRI of relapse revealed more small lesions in the subcortical and periventricular white matter in the patients. In the second episode, only 2 cases presented cortical involvement. Lesions were found in the brain stem in 4 cases and in the cerebellum in 5 cases. Pyramidal tract

  17. A simple MRI protocol in patients with clinically suspected appendicitis: results in 138 patients and effect on outcome of appendectomy

    International Nuclear Information System (INIS)

    Cobben, Lodewijk; Groot, Ingrid; Kingma, Lucas; Coerkamp, Emile; Puylaert, Julien; Blickman, Johan

    2009-01-01

    To establish the value of breathhold magnetic resonance imaging (MRI) in the diagnosis of acute appendicitis. Over a 14-month period, 138 patients clinically suspected of having appendicitis were evaluated prospectively with MRI and comprised the study group. Fast turbo spin-echo breathhold T1, T2 and T2 fat suppression sequences were used in coronal and axial planes. The imaging results were recorded separately and subsequently correlated with clinical, radiological and histopathological follow-up. The effect of imaging strategies in patients suspected of appendicitis on hospital resources was calculated. Sixty-two of the 138 patients had a histopathologically proven appendicitis. MRI determined appendicitis in 63 patients, with one examination being false positive. The resulting sensitivity and specificity were 100% and 99%, respectively. MRI showed an alternative diagnosis in 41 of the 75 remaining patients. In 22 of the remaining 34 patients, a normal appendix was depicted with MRI. In two patients, where MRI showed no appendicitis, an alternative diagnosis or normal appendix, an unnecessary appendectomy was performed. The overall effect of using MRI in patients suspected of appendicitis on the use of hospital resources could have been a net saving between EUR 55,746 and EUR 72,534. MRI has a high accuracy in detecting and excluding appendicitis, an alternative diagnosis or showing the normal appendix, and can be a valuable and cost-effective tool in the workup of patients clinically suspected of having appendicitis. (orig.)

  18. A simple MRI protocol in patients with clinically suspected appendicitis: results in 138 patients and effect on outcome of appendectomy

    Energy Technology Data Exchange (ETDEWEB)

    Cobben, Lodewijk [Medisch Centrum Haaglanden, Department of Radiology, Leidschendam (Netherlands); Groot, Ingrid [Medisch Centrum Haaglanden, Department of Surgery, Leidschendam (Netherlands); Kingma, Lucas; Coerkamp, Emile; Puylaert, Julien [Medisch Centrum Haaglanden, Department of Radiology, Den Haag (Netherlands); Blickman, Johan [Universitair Medisch Centrum St Radboud, Department of Radiology, Geert Grooteplein 10, GA, Nijmegen (Netherlands)

    2009-05-15

    To establish the value of breathhold magnetic resonance imaging (MRI) in the diagnosis of acute appendicitis. Over a 14-month period, 138 patients clinically suspected of having appendicitis were evaluated prospectively with MRI and comprised the study group. Fast turbo spin-echo breathhold T1, T2 and T2 fat suppression sequences were used in coronal and axial planes. The imaging results were recorded separately and subsequently correlated with clinical, radiological and histopathological follow-up. The effect of imaging strategies in patients suspected of appendicitis on hospital resources was calculated. Sixty-two of the 138 patients had a histopathologically proven appendicitis. MRI determined appendicitis in 63 patients, with one examination being false positive. The resulting sensitivity and specificity were 100% and 99%, respectively. MRI showed an alternative diagnosis in 41 of the 75 remaining patients. In 22 of the remaining 34 patients, a normal appendix was depicted with MRI. In two patients, where MRI showed no appendicitis, an alternative diagnosis or normal appendix, an unnecessary appendectomy was performed. The overall effect of using MRI in patients suspected of appendicitis on the use of hospital resources could have been a net saving between EUR 55,746 and EUR 72,534. MRI has a high accuracy in detecting and excluding appendicitis, an alternative diagnosis or showing the normal appendix, and can be a valuable and cost-effective tool in the workup of patients clinically suspected of having appendicitis. (orig.)

  19. Clinical functional MRI. Persurgical functional neuroimaging. 2. ed.

    International Nuclear Information System (INIS)

    Stippich, Christoph

    2015-01-01

    The second, revised edition of this successful textbook provides an up-to-date description of the use of preoperative fMRI in patients with brain tumors and epilepsies. State of the art fMRI procedures are presented, with detailed consideration of practical aspects, imaging and data processing, normal and pathological findings, and diagnostic possibilities and limitations. Relevant information on brain physiology, functional neuroanatomy, imaging technique, and methodology is provided by recognized experts in these fields. Compared with the first edition, chapters have been updated to reflect the latest developments and in particular the current use of diffusion tensor imaging (DTI) and resting-state fMRI. Entirely new chapters are included on resting-state presurgical fMRI and the role of DTI and tractography in brain tumor surgery. Further chapters address multimodality functional neuroimaging, brain plasticity, and pitfalls, tips, and tricks.

  20. Clinical functional MRI. Persurgical functional neuroimaging. 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Stippich, Christoph (ed.) [Univ. Hospitals Basel (Switzerland). Division of Diagnostic and Inventional Neuroradiology

    2015-06-01

    The second, revised edition of this successful textbook provides an up-to-date description of the use of preoperative fMRI in patients with brain tumors and epilepsies. State of the art fMRI procedures are presented, with detailed consideration of practical aspects, imaging and data processing, normal and pathological findings, and diagnostic possibilities and limitations. Relevant information on brain physiology, functional neuroanatomy, imaging technique, and methodology is provided by recognized experts in these fields. Compared with the first edition, chapters have been updated to reflect the latest developments and in particular the current use of diffusion tensor imaging (DTI) and resting-state fMRI. Entirely new chapters are included on resting-state presurgical fMRI and the role of DTI and tractography in brain tumor surgery. Further chapters address multimodality functional neuroimaging, brain plasticity, and pitfalls, tips, and tricks.

  1. PET performance and MRI compatibility evaluation of a digital, ToF-capable PET/MRI insert equipped with clinical scintillators

    International Nuclear Information System (INIS)

    Schug, David; Wehner, Jakob; Dueppenbecker, Peter Michael; Weissler, Bjoern; Goldschmidt, Benjamin; Schulz, Volkmar; Gebhardt, Pierre; Salomon, Andre; Kiessling, Fabian

    2015-01-01

    We evaluate the MR compatibility of the Hyperion-II D positron emission tomography (PET) insert, which allows simultaneous operation in a clinical magnetic resonance imaging (MRI) scanner. In contrast to previous investigations, this work aims at the evaluation of a clinical crystal configuration. An imaging-capable demonstrator with an axial field-of-view of 32 mm and a crystal-to-crystal spacing of 217.6 mm was equipped with LYSO scintillators with a pitch of 4 mm which were read out in a one-to-one coupling scheme by sensor tiles composed of digital silicon photomultipliers from Philips Digital Photon Counting (DPC 3200-22). The PET performance degradation (energy resolution and coincidence resolution time (CRT)) was evaluated during simultaneous operation of the MRI scanner. We used clinically motivated imaging sequences as well as synthetic gradient stress test sequences. Without activity of the MRI scanner, we measured for trigger scheme 1 (first photon trigger) an energy resolution of 11.4% and a CRT of 213 ps for a narrow energy (NE) window using five 22 Na point-like sources. When applying the synthetic gradient sequences, we found worst-case relative degradations of the energy resolution by 5.1% and of the CRT by 33.9%. After identifying the origin of the degradations and implementing a fix to the read-out hardware, the same evaluation revealed no degradation of the PET performance anymore even when the most demanding gradient stress tests were applied. The PET performance of the insert was initially evaluated using the point sources, a high-activity phantom and hot-rod phantoms in order to assess the spatial resolution. Trigger schemes 2–4 delivered an energy resolution of 11.4% as well and CRTs of 279 ps, 333 ps and 557 ps for the NE window, respectively. An isocenter sensitivity of 0.41% using the NE window and 0.71% with a wide energy window was measured. Using a hot-rod phantom, a spatial resolution in the order of 2 mm was demonstrated and

  2. PET performance and MRI compatibility evaluation of a digital, ToF-capable PET/MRI insert equipped with clinical scintillators

    Science.gov (United States)

    Schug, David; Wehner, Jakob; Dueppenbecker, Peter Michael; Weissler, Bjoern; Gebhardt, Pierre; Goldschmidt, Benjamin; Salomon, Andre; Kiessling, Fabian; Schulz, Volkmar

    2015-09-01

    We evaluate the MR compatibility of the Hyperion-IID positron emission tomography (PET) insert, which allows simultaneous operation in a clinical magnetic resonance imaging (MRI) scanner. In contrast to previous investigations, this work aims at the evaluation of a clinical crystal configuration. An imaging-capable demonstrator with an axial field-of-view of 32 mm and a crystal-to-crystal spacing of 217.6 mm was equipped with LYSO scintillators with a pitch of 4 mm which were read out in a one-to-one coupling scheme by sensor tiles composed of digital silicon photomultipliers from Philips Digital Photon Counting (DPC 3200-22). The PET performance degradation (energy resolution and coincidence resolution time (CRT)) was evaluated during simultaneous operation of the MRI scanner. We used clinically motivated imaging sequences as well as synthetic gradient stress test sequences. Without activity of the MRI scanner, we measured for trigger scheme 1 (first photon trigger) an energy resolution of 11.4% and a CRT of 213 ps for a narrow energy (NE) window using five 22Na point-like sources. When applying the synthetic gradient sequences, we found worst-case relative degradations of the energy resolution by 5.1% and of the CRT by 33.9%. After identifying the origin of the degradations and implementing a fix to the read-out hardware, the same evaluation revealed no degradation of the PET performance anymore even when the most demanding gradient stress tests were applied. The PET performance of the insert was initially evaluated using the point sources, a high-activity phantom and hot-rod phantoms in order to assess the spatial resolution. Trigger schemes 2-4 delivered an energy resolution of 11.4% as well and CRTs of 279 ps, 333 ps and 557 ps for the NE window, respectively. An isocenter sensitivity of 0.41% using the NE window and 0.71% with a wide energy window was measured. Using a hot-rod phantom, a spatial resolution in the order of 2 mm was demonstrated and the

  3. Indications, advantages and limitations of perinatal postmortem imaging in clinical practice

    International Nuclear Information System (INIS)

    Arthurs, Owen J.; Taylor, Andrew M.; Sebire, Neil J.

    2015-01-01

    Just as there is a range of paediatric imaging techniques available during life, a similar repertoire is available as part of the foetal and perinatal postmortem examination. In this article, we review the literature regarding the diagnostic utility of postmortem radiography, US, CT and MRI in this clinical setting. There is limited direct evidence on the diagnostic utility of any of these techniques, apart from postmortem MRI, which when combined with other noninvasive investigations, has been shown to be highly sensitive and specific for many foetal postmortem diagnoses. The main disadvantages of postmortem MRI include the longer duration of imaging, the need for appropriate training in the interpretation of normal postmortem changes, and possible non-diagnostic imaging examinations in early gestation fetuses. As less-invasive autopsy becomes increasingly available, the true utility of these techniques will evolve, and clinical guidelines for maximal diagnostic yield can be developed. (orig.)

  4. Indications, advantages and limitations of perinatal postmortem imaging in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Arthurs, Owen J. [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Radiology, London (United Kingdom); University College London, Institute of Child Health, London (United Kingdom); Taylor, Andrew M. [Great Ormond Street Hospital for Children NHS Foundation Trust, Cardiorespiratory Division, London (United Kingdom); Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science, London (United Kingdom); Sebire, Neil J. [University College London, Institute of Child Health, London (United Kingdom); Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Histopathology, London (United Kingdom)

    2015-04-01

    Just as there is a range of paediatric imaging techniques available during life, a similar repertoire is available as part of the foetal and perinatal postmortem examination. In this article, we review the literature regarding the diagnostic utility of postmortem radiography, US, CT and MRI in this clinical setting. There is limited direct evidence on the diagnostic utility of any of these techniques, apart from postmortem MRI, which when combined with other noninvasive investigations, has been shown to be highly sensitive and specific for many foetal postmortem diagnoses. The main disadvantages of postmortem MRI include the longer duration of imaging, the need for appropriate training in the interpretation of normal postmortem changes, and possible non-diagnostic imaging examinations in early gestation fetuses. As less-invasive autopsy becomes increasingly available, the true utility of these techniques will evolve, and clinical guidelines for maximal diagnostic yield can be developed. (orig.)

  5. Magnetic Resonance Imaging (MRI): Dynamic Pelvic Floor

    Science.gov (United States)

    ... to a CD or uploaded to a digital cloud server. Dynamic pelvic floor MRI provides detailed pictures ... with you. top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging ...

  6. [Imaging of the elbow joint with focus MRI. Part 2: muscles, nerves and synovial membranes].

    Science.gov (United States)

    Rehm, J; Zeifang, F; Weber, M-A

    2014-03-01

    This review article discusses the magnetic resonance imaging (MRI) features and pathological changes of muscles, nerves and the synovial lining of the elbow joint. Typical imaging findings are illustrated and discussed. In addition, the cross-sectional anatomy and anatomical variants, such as accessory muscles and plicae are discussed. Injuries of the muscles surrounding the elbow joint, as well as chronic irritation are particularly common in athletes. Morphological changes in MRI, for example tennis or golfer's elbow are typical and often groundbreaking. By adapting the examination sequences, imaging planes and slices, complete and incomplete tendon ruptures can be reliably diagnosed. Although the clinical and electrophysiological examinations form the basis for the diagnosis of peripheral neuropathies, MRI provides useful additional information about the precise localization due to its high resolution and good soft tissue contrast and helps to rule out differential diagnoses. Synovial diseases, such as inflammatory arthritis, proliferative diseases and also impinging plicae must be considered in the MRI diagnostics of the elbow joint.

  7. Initial tests of a prototype MRI-compatible PET imager

    International Nuclear Information System (INIS)

    Raylman, Raymond R.; Majewski, Stan; Lemieux, Susan; Velan, S. Sendhil; Kross, Brain; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.; Wojcik, Randy

    2006-01-01

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI, will allow the correlation of form with function. Our group (a collaboration of West Virginia University and Jefferson Lab) is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode with an active FOV of 5x5x4 cm 3 . Each MRI-PET detector module consists of an array of LSO detector elements (2.5x2.5x15 mm 3 ) coupled through a long fiber optic light guide to a single Hamamatsu flat panel PSPMT. The fiber optic light guide is made of a glued assembly of 2 mm diameter acrylic fibers with a total length of 2.5 m. The use of a light guides allows the PSPMTs to be positioned outside the bore of the 3 T General Electric MRI scanner used in the tests. Photon attenuation in the light guides resulted in an energy resolution of ∼60% FWHM, interaction of the magnetic field with PSPMT further reduced energy resolution to ∼85% FWHM. Despite this effect, excellent multi-plane PET and MRI images of a simple disk phantom were acquired simultaneously. Future work includes improved light guides, optimized magnetic shielding for the PSPMTs, construction of specialized coils to permit high-resolution MRI imaging, and use of the system to perform simultaneous PET and MRI or MR-spectroscopy

  8. Contrast-enhanced MRI of the knee in children unaffected by clinical arthritis compared to clinically active juvenile idiopathic arthritis patients

    Energy Technology Data Exchange (ETDEWEB)

    Nusman, Charlotte M.; Hemke, Robert [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Benninga, Marc A.; Kindermann, Angelika [University of Amsterdam, Department of Pediatric Gastroenterology, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Schonenberg-Meinema, Dieneke; Berg, J.M. van den; Kuijpers, Taco W. [University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Rossum, Marion A.J. van [University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Reade, Department of Pediatric Rheumatology, Amsterdam (Netherlands); Maas, Mario [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands)

    2016-04-15

    To evaluate enhancing synovial thickness upon contrast-enhanced magnetic resonance imaging (MRI) of the knee in children unaffected by clinical arthritis compared with clinically active juvenile idiopathic arthritis (JIA) patients. A secondary objective was optimization of the scoring method based on maximizing differences on MRI between these groups. Twenty-five children without history of joint complaints nor any clinical signs of joint inflammation were age/sex-matched with 25 clinically active JIA patients with arthritis of at least one knee. Two trained radiologists, blinded for clinical status, independently evaluated location and extent of enhancing synovial thickness with the validated Juvenile Arthritis MRI Scoring system (JAMRIS) on contrast-enhanced axial fat-saturated T1-weighted MRI of the knee. Enhancing synovium (≥2 mm) was present in 13 (52 %) unaffected children. Using the total JAMRIS score for synovial thickening, no significant difference was found between unaffected children and active JIA patients (p = 0.091). Additional weighting of synovial thickening at the JIA-specific locations enabled more sensitive discrimination (p = 0.011). Mild synovial thickening is commonly present in the knee of children unaffected by clinical arthritis. The infrapatellar and cruciate ligament synovial involvement were specific for JIA, which - in a revised JAMRIS - increases the ability to discriminate between JIA and unaffected children. (orig.)

  9. Contrast-enhanced MRI of the knee in children unaffected by clinical arthritis compared to clinically active juvenile idiopathic arthritis patients

    International Nuclear Information System (INIS)

    Nusman, Charlotte M.; Hemke, Robert; Benninga, Marc A.; Kindermann, Angelika; Schonenberg-Meinema, Dieneke; Berg, J.M. van den; Kuijpers, Taco W.; Rossum, Marion A.J. van; Maas, Mario

    2016-01-01

    To evaluate enhancing synovial thickness upon contrast-enhanced magnetic resonance imaging (MRI) of the knee in children unaffected by clinical arthritis compared with clinically active juvenile idiopathic arthritis (JIA) patients. A secondary objective was optimization of the scoring method based on maximizing differences on MRI between these groups. Twenty-five children without history of joint complaints nor any clinical signs of joint inflammation were age/sex-matched with 25 clinically active JIA patients with arthritis of at least one knee. Two trained radiologists, blinded for clinical status, independently evaluated location and extent of enhancing synovial thickness with the validated Juvenile Arthritis MRI Scoring system (JAMRIS) on contrast-enhanced axial fat-saturated T1-weighted MRI of the knee. Enhancing synovium (≥2 mm) was present in 13 (52 %) unaffected children. Using the total JAMRIS score for synovial thickening, no significant difference was found between unaffected children and active JIA patients (p = 0.091). Additional weighting of synovial thickening at the JIA-specific locations enabled more sensitive discrimination (p = 0.011). Mild synovial thickening is commonly present in the knee of children unaffected by clinical arthritis. The infrapatellar and cruciate ligament synovial involvement were specific for JIA, which - in a revised JAMRIS - increases the ability to discriminate between JIA and unaffected children. (orig.)

  10. Prediction of standard-dose brain PET image by using MRI and low-dose brain [{sup 18}F]FDG PET images

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jiayin [School of Electronics Engineering, Huaihai Institute of Technology, Lianyungang, Jiangsu 222005, China and IDEA Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Gao, Yaozong [IDEA Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 and Department of Computer Science, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Shi, Feng [IDEA Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Lalush, David S. [Joint UNC-NCSU Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States); Lin, Weili [MRI Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Shen, Dinggang, E-mail: dgshen@med.unc.edu [IDEA Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 and Department of Brain and Cognitive Engineering, Korea University, Seoul 136-713 (Korea, Republic of)

    2015-09-15

    Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. As yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain [{sup 18}F]FDG PET image by using a low-dose brain [{sup 18}F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain [{sup 18}F]FDG PET image by low-dose brain [{sup 18}F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain [{sup 18}F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain [{sup 18}F]FDG PET

  11. Prediction of standard-dose brain PET image by using MRI and low-dose brain ["1"8F]FDG PET images

    International Nuclear Information System (INIS)

    Kang, Jiayin; Gao, Yaozong; Shi, Feng; Lalush, David S.; Lin, Weili; Shen, Dinggang

    2015-01-01

    Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. As yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain ["1"8F]FDG PET image by using a low-dose brain ["1"8F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain ["1"8F]FDG PET image by low-dose brain ["1"8F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain ["1"8F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain ["1"8F]FDG PET image and substantially

  12. Relationship between clinical findings of temporomandibular disorders and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Iizuka, Yasuyuki; Miura, Hiroyuki; Ishikawa, Fujiro; Kikuchi, Shiori; Konishi, Nobuhiro; Sakamaki, Kimio

    1996-01-01

    The present study was conducted to investigate the relationship between magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ) and clinical findings of patients having symptoms of temporomandibular disorders, and to consider the possibility to grasp the internal derangement of the TMJ from clinical findings. Subjects were 80 patients who visited to ask orthodontic treatment 16 males and 64 females. The average age was 22 years and 4 months. We performed a investigation of both their previous and present illness. In addition, to decide the correct condition concerning the internal derangement of the TMJ, patients were given MRI examinations (G. E. medical system Signa 1.5 Tesla) before orthodontic treatment. Results were as follows: The three symptoms of temporomandibular disorders-noise, pain, and abnormal mandibular movement, were not related to constant disk displacement. It seemed difficult to infer and obtain the diagnosis of the condition of internal derangement of the TMJ only from clinical findings. In a dental clinics having no medical imaging instrument such as MRI, it was, however, considered that the following items will make it possible to define the condition of internal derangements of the TMJ from clinical findings. As to respects concerning clinical findings, it is necessary to consider the previous illness as well as present illness. TMJ noise indicates a higher relationship to the disk displacement in MRI findings. The temporomandibular joint with plural symptoms indicated a higher incidence of disk displacement examined by MR Imaging than that with a single symptom. (author)

  13. Cardiac MRI in patients with complex CHD following primary or secondary implantation of MRI-conditional pacemaker system.

    Science.gov (United States)

    Al-Wakeel, Nadya; O h-Ici, Darach; Schmitt, Katharina R; Messroghli, Daniel R; Riesenkampff, Eugénie; Berger, Felix; Kuehne, Titus; Peters, Bjoern

    2016-02-01

    In patients with CHD, cardiac MRI is often indicated for functional and anatomical assessment. With the recent introduction of MRI-conditional pacemaker systems, cardiac MRI has become accessible for patients with pacemakers. The present clinical study aims to evaluate safety, susceptibility artefacts, and image reading of cardiac MRI in patients with CHD and MRI-conditional pacemaker systems. Material and methods CHD patients with MRI-conditional pacemaker systems and a clinical need for cardiac MRI were examined with a 1.5-T MRI system. Lead function was tested before and after MRI. Artefacts and image readings were evaluated using a four-point grading scale. A total of nine patients with CHD (mean age 34.0 years, range 19.5-53.6 years) received a total of 11 cardiac MRI examinations. Owing to clinical indications, seven patients had previously been converted from conventional to MRI-conditional pacemaker systems. All MRI examinations were completed without adverse effects. Device testing immediately after MRI and at follow-up showed no alteration of pacemaker device and lead function. Clinical questions could be addressed and answered in all patients. Cardiac MRI can be performed safely with high certainty of diagnosis in CHD patients with MRI-conditional pacemaker systems. In case of clinically indicated lead and box changing, CHD patients with non-MRI-conditional pacemaker systems should be considered for complete conversion to MRI-conditional systems.

  14. A comparison of accuracy of clinical tests and MRI in the diagnosis ...

    African Journals Online (AJOL)

    Objective: To compare the accuracy of clinical examination versus Magnetic Resonance Imaging (MRI) in the diagnoses of meniscal and Anterior Cruciate Ligament (ACL) tears after trauma. Methods: Between January 2011 and December 2015, 147 consecutive patients with previous history of knee injury were seen and ...

  15. Magnetic Resonance Medical Imaging (MRI)-from the inside

    Science.gov (United States)

    Bottomley, Paul

    There are about 36,000 magnetic resonance imaging (MRI) scanners in the world, with annual sales of 2500. In the USA about 34 million MRI studies are done annually, and 60-70% of all scanners operate at 1.5 Tesla (T). In 1982 there were none. How MRI got to be-and how it got to1.5T is the subject of this talk. Its an insider's view-mine-as a physics PhD student at Nottingham University when MRI (almost) began, through to the invention of the 1.5T clinical MRI scanner at GE's research center in Schenectady NY.Before 1977 all MRI was done on laboratory nuclear magnetic resonance instruments used for analyzing small specimens via chemical shift spectroscopy (MRS). It began with Lauterbur's 1973 observation that turning up the spectrometer's linear gradient magnetic field, generated a spectrum that was a 1D projection of the sample in the direction of the gradient. What followed in the 70's was the development of 3 key methods of 3D spatial localization that remain fundamental to MRI today.As the 1980's began, the once unimaginable prospect of upscaling from 2cm test-tubes to human body-sized magnets, gradient and RF transmit/receive systems, was well underway, evolving from arm-sized, to whole-body electromagnet-based systems operating at plan was to drop the field to 0.3T. We opted to make MRI work at 1.5T instead. The result was a scanner that could study both anatomy and metabolism with a SNR way beyond its lower field rivals. MRI's success truly reflects the team efforts of many: from the NMR physics to the engineering of magnets, gradient and RF systems.

  16. Repaired supraspinatus tendons in clinically improving patients: Early postoperative findings and interval changes on MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Eun; Park, Ji Seon; Ryu, Kyung Nam; Rhee, Yong Girl [Kyung Hee University Hospital, Seoul (Korea, Republic of); Yoon, So Hee; Park, So Young; Jin Wook [Dept. of Radiology, Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of)

    2015-04-15

    To demonstrate and further determine the incidences of repaired supraspinatus tendons on early postoperative magnetic resonance imaging (MRI) findings in clinically improving patients and to evaluate interval changes on follow-up MRIs. Fifty patients, who showed symptomatic and functional improvements after supraspinatus tendon repair surgery and who underwent postoperative MRI twice with a time interval, were included. The first and the second postoperative MRIs were obtained a mean of 4.4 and 11.5 months after surgery, respectively. The signal intensity (SI) patterns of the repaired tendon on T2-weighted images from the first MRI were classified into three types of heterogeneous high SI with fluid-like bright high foci (type I), heterogeneous high SI without fluid-like bright high foci (type II), and heterogeneous or homogeneous low SI (type III). Interval changes in the SI pattern, tendon thickness, and rotator cuff interval thickness between the two postoperative MRIs were evaluated. The SI patterns on the first MRI were type I or II in 45 tendons (90%) and type III in five (10%). SI decreased significantly on the second MRI (p < 0.050). The mean thickness of repaired tendons and rotator cuff intervals also decreased significantly (p < 0.050). Repaired supraspinatus tendons exhibited high SI in 90% of clinically improving patients on MRI performed during the early postsurgical period. The increased SI and thickness of the repaired tendon decreased on the later MRI, suggesting a gradual healing process rather than a retear.

  17. Repaired supraspinatus tendons in clinically improving patients: Early postoperative findings and interval changes on MRI

    International Nuclear Information System (INIS)

    Lee, Jung Eun; Park, Ji Seon; Ryu, Kyung Nam; Rhee, Yong Girl; Yoon, So Hee; Park, So Young; Jin Wook

    2015-01-01

    To demonstrate and further determine the incidences of repaired supraspinatus tendons on early postoperative magnetic resonance imaging (MRI) findings in clinically improving patients and to evaluate interval changes on follow-up MRIs. Fifty patients, who showed symptomatic and functional improvements after supraspinatus tendon repair surgery and who underwent postoperative MRI twice with a time interval, were included. The first and the second postoperative MRIs were obtained a mean of 4.4 and 11.5 months after surgery, respectively. The signal intensity (SI) patterns of the repaired tendon on T2-weighted images from the first MRI were classified into three types of heterogeneous high SI with fluid-like bright high foci (type I), heterogeneous high SI without fluid-like bright high foci (type II), and heterogeneous or homogeneous low SI (type III). Interval changes in the SI pattern, tendon thickness, and rotator cuff interval thickness between the two postoperative MRIs were evaluated. The SI patterns on the first MRI were type I or II in 45 tendons (90%) and type III in five (10%). SI decreased significantly on the second MRI (p < 0.050). The mean thickness of repaired tendons and rotator cuff intervals also decreased significantly (p < 0.050). Repaired supraspinatus tendons exhibited high SI in 90% of clinically improving patients on MRI performed during the early postsurgical period. The increased SI and thickness of the repaired tendon decreased on the later MRI, suggesting a gradual healing process rather than a retear.

  18. Current and future diagnostic tools for traumatic brain injury: CT, conventional MRI, and diffusion tensor imaging.

    Science.gov (United States)

    Brody, David L; Mac Donald, Christine L; Shimony, Joshua S

    2015-01-01

    Brain imaging plays a key role in the assessment of traumatic brain injury. In this review, we present our perspectives on the use of computed tomography (CT), conventional magnetic resonance imaging (MRI), and newer advanced modalities such as diffusion tensor imaging. Specifically, we address assessment for immediately life-threatening intracranial lesions (noncontrast head CT), assessment of progression of intracranial lesions (noncontrast head CT), documenting intracranial abnormalities for medicolegal reasons (conventional MRI with blood-sensitive sequences), presurgical planning for post-traumatic epilepsy (high spatial resolution conventional MRI), early prognostic decision making (conventional MRI with diffusion-weighted imaging), prognostic assessment for rehabilitative planning (conventional MRI and possibly diffusion tensor imaging in the future), stratification of subjects and pharmacodynamic tracking of targeted therapies in clinical trials (specific MRI sequences or positron emission tomography (PET) ligands, e.g., diffusion tensor imaging for traumatic axonal injury). We would like to emphasize that all of these methods, especially the newer research approaches, require careful radiologic-pathologic validation for optimal interpretation. We have taken this approach in a mouse model of pericontusional traumatic axonal injury. We found that the extent of reduction in the diffusion tensor imaging parameter relative anisotropy directly correlated with the number of amyloid precursor protein (APP)-stained axonal varicosities (r(2)=0.81, p<0.0001, n=20 injured mice). Interestingly, however, the least severe contusional injuries did not result in APP-stained axonal varicosities, but did cause reduction in relative anisotropy. Clearly, both the imaging assessments and the pathologic assessments will require iterative refinement. © 2015 Elsevier B.V. All rights reserved.

  19. The use of parallel imaging for MRI assessment of knees in children and adolescents.

    Science.gov (United States)

    Doria, Andrea S; Chaudry, Gulraiz A; Nasui, Cristina; Rayner, Tammy; Wang, Chenghua; Moineddin, Rahim; Babyn, Paul S; White, Larry M; Sussman, Marshall S

    2010-03-01

    Parallel imaging provides faster scanning at the cost of reduced signal-to-noise ratio (SNR) and increased artifacts. To compare the diagnostic performance of two parallel MRI protocols (PPs) for assessment of pathologic knees using an 8-channel knee coil (reference standard, conventional protocol [CP]) and to characterize the SNR losses associated with parallel imaging. Two radiologists blindly interpreted 1.5 Tesla knee MRI images in 21 children (mean 13 years, range 9-18 years) with clinical indications for an MRI scan. Sagittal proton density, T2-W fat-saturated FSE, axial T2-W fat-saturated FSE, and coronal T1-W (NEX of 1,1,1) images were obtained with both CP and PP. Images were read for soft tissue and osteochondral findings. There was a 75% decrease in acquisition time using PP in comparison to CP. The CP and PP protocols fell within excellent or upper limits of substantial agreement: CP, kappa coefficient, 0.81 (95% CIs, 0.73-0.89); PP, 0.80-0.81 (0.73-0.89). The sensitivity of the two PPs was similar for assessment of soft (0.98-1.00) and osteochondral (0.89-0.94) tissues. Phantom data indicated an SNR of 1.67, 1.6, and 1.51 (axial, sagittal and coronal planes) between CP and PP scans. Parallel MRI provides a reliable assessment for pediatric knees in a significantly reduced scan time without affecting the diagnostic performance of MRI.

  20. Intramedullary disorders diagnosed by MRI. Clinical course in 23 cases

    International Nuclear Information System (INIS)

    Nagata, Kensei; Ohashi, Teruaki; Ishibashi, Kazumasa; Hirohashi, Akiyuki; Sato, Kimiaki

    1996-01-01

    We report the clinical course of 23 cases with intramedullary disorders diagnosed by MRI. Spinal vascular disease was the most common, and occurred in 11 cases, intramedullary tumor occurred in 6, and multiple sclerosis, myelitis, spinal edema each in 2. The characteristic MRI findings of the intramedullary disorders were spinal cord swelling on T1 weighted image and changes in the intensity on the T2 weighted image. Surgical treatment was performed in 5 of the 11 with spinal vascular disease and in 6 with an intra-medullary tumor. One patient with AV malformation underwent embolization of the spinal artery. The other 11 received conservative treatment. The period of follow-up ranged from 6 months to 9 years after onset. Complete recovery from symptoms was achieved in only 2 patients, some recovery was achieved in 8, no change in 10, and deterioration occurred in 3. In conclusion, it has become easy to diagnose intramedullary disorders by utilizing MRI. However, an accurate qualitative diagnosis is difficult except for spinal vascular disease. Complete recovery from the symptoms of intramedullary disorders remains difficult to achieve by available treatments. (author)

  1. Intramedullary disorders diagnosed by MRI. Clinical course in 23 cases

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Kensei; Ohashi, Teruaki; Ishibashi, Kazumasa; Hirohashi, Akiyuki; Sato, Kimiaki [Kurume Univ., Fukuoka (Japan). School of Medicine

    1996-09-01

    We report the clinical course of 23 cases with intramedullary disorders diagnosed by MRI. Spinal vascular disease was the most common, and occurred in 11 cases, intramedullary tumor occurred in 6, and multiple sclerosis, myelitis, spinal edema each in 2. The characteristic MRI findings of the intramedullary disorders were spinal cord swelling on T1 weighted image and changes in the intensity on the T2 weighted image. Surgical treatment was performed in 5 of the 11 with spinal vascular disease and in 6 with an intra-medullary tumor. One patient with AV malformation underwent embolization of the spinal artery. The other 11 received conservative treatment. The period of follow-up ranged from 6 months to 9 years after onset. Complete recovery from symptoms was achieved in only 2 patients, some recovery was achieved in 8, no change in 10, and deterioration occurred in 3. In conclusion, it has become easy to diagnose intramedullary disorders by utilizing MRI. However, an accurate qualitative diagnosis is difficult except for spinal vascular disease. Complete recovery from the symptoms of intramedullary disorders remains difficult to achieve by available treatments. (author)

  2. Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Mehranian, Abolfazl; Arabi, Hossein [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva CH-1211 (Switzerland); Zaidi, Habib, E-mail: habib.zaidi@hcuge.ch [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva CH-1211 (Switzerland); Geneva Neuroscience Centre, University of Geneva, Geneva CH-1205 (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University of Groningen, Groningen 9700 RB (Netherlands)

    2016-03-15

    Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing novel strategies for deriving accurate attenuation maps with the aim to improve the quantitative accuracy of these emerging hybrid imaging systems. The attenuation map in PET/MRI should ideally be derived from anatomical MR images; however, MRI intensities reflect proton density and relaxation time properties of biological tissues rather than their electron density and photon attenuation properties. Therefore, in contrast to PET/computed tomography, there is a lack of standardized global mapping between the intensities of MRI signal and linear attenuation coefficients at 511 keV. Moreover, in standard MRI sequences, bones and lung tissues do not produce measurable signals owing to their low proton density and short transverse relaxation times. MR images are also inevitably subject to artifacts that degrade their quality, thus compromising their applicability for the task of attenuation correction in PET/MRI. MRI-guided attenuation correction strategies can be classified in three broad categories: (i) segmentation-based approaches, (ii) atlas-registration and machine learning methods, and (iii) emission/transmission-based approaches. This paper summarizes past and current state-of-the-art developments and latest advances in PET/MRI attenuation correction. The advantages and drawbacks of each approach for addressing the challenges of MR-based attenuation correction are comprehensively described. The opportunities brought by both MRI and PET imaging modalities for deriving accurate attenuation maps and improving PET quantification will be elaborated. Future prospects and potential clinical applications of these techniques and their integration in commercial

  3. Imaging brain microstructure with diffusion MRI

    DEFF Research Database (Denmark)

    Alexander, Daniel C; Dyrby, Tim B; Nilsson, Markus

    2018-01-01

    This article gives an overview of microstructure imaging of the brain with diffusion MRI and reviews the state of the art. The microstructure-imaging paradigm aims to estimate and map microscopic properties of tissue using a model that links these properties to the voxel scale MR signal. Imaging ...

  4. Utility of Clinical Parameters and Multiparametric MRI as Predictive Factors for Differentiating Uterine Sarcoma From Atypical Leiomyoma.

    Science.gov (United States)

    Bi, Qiu; Xiao, Zhibo; Lv, Fajin; Liu, Yao; Zou, Chunxia; Shen, Yiqing

    2018-02-05

    The objective of this study was to find clinical parameters and qualitative and quantitative magnetic resonance imaging (MRI) features for differentiating uterine sarcoma from atypical leiomyoma (ALM) preoperatively and to calculate predictive values for uterine sarcoma. Data from 60 patients with uterine sarcoma and 88 patients with ALM confirmed by surgery and pathology were collected. Clinical parameters, qualitative MRI features, diffusion-weighted imaging with apparent diffusion coefficient values, and quantitative parameters of dynamic contrast-enhanced MRI of these two tumor types were compared. Predictive values for uterine sarcoma were calculated using multivariable logistic regression. Patient clinical manifestations, tumor locations, margins, T2-weighted imaging signals, mean apparent diffusion coefficient values, minimum apparent diffusion coefficient values, and time-signal intensity curves of solid tumor components were obvious significant parameters for distinguishing between uterine sarcoma and ALM (all P Abnormal vaginal bleeding, tumors located mainly in the uterine cavity, ill-defined tumor margins, and mean apparent diffusion coefficient values of uterine sarcoma. When the overall scores of these four predictors were greater than or equal to 7 points, the sensitivity, the specificity, the accuracy, and the positive and negative predictive values were 88.9%, 99.9%, 95.7%, 97.0%, and 95.1%, respectively. The use of clinical parameters and multiparametric MRI as predictive factors was beneficial for diagnosing uterine sarcoma preoperatively. These findings could be helpful for guiding treatment decisions. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  5. Coronary imaging techniques with emphasis on CT and MRI

    International Nuclear Information System (INIS)

    Lederlin, Mathieu; Latrabe, Valerie; Corneloup, Olivier; Cochet, Hubert; Montaudon, Michel; Laurent, Francois; Thambo, Jean-Benoit

    2011-01-01

    Coronary artery imaging in children is challenging, with high demands both on temporal and spatial resolution due to high heart rates and smaller anatomy. Although invasive conventional coronary angiography remains the benchmark technique, over the past 10 years, CT and MRI have emerged in the field of coronary imaging. The choice of hardware is important. For CT, the minimum requirement is a 64-channel scanner. The temporal resolution of the scanner is most important for optimising image quality and minimising radiation dose. Manufacturers have developed several modes of electrocardiographic (ECG) triggering to facilitate dose reduction. Recent technical advances have opened new possibilities in MRI coronary imaging. As a non-ionising radiation technique, MRI is of great interest in paediatric imaging. It is currently recommended in centres with appropriate expertise for the screening of patients with suspected congenital coronary anomalies. However, MRI is still not feasible in infants. This review describes and discusses the technical requirements and the pros and cons of all three techniques. (orig.)

  6. Isolated lipoma of filum terminale in adults: MRI findings and clinical correlation

    International Nuclear Information System (INIS)

    Al-Omari, Ma'moon H.; Qudseih, Hana' M.; Al-shinag, Mohammad K.; Eloqayli, Haytham M.

    2011-01-01

    Fat within the filum terminale is frequently seen on routine magnetic resonance imaging (MRI) of the lumbosacral spine (LSS), with prevalence of 1–5%. The objective of this study was to determine the prevalence and MRI features of isolated lipoma of filum terminale (LFT) in adult population and its correlation with the patient clinical presentations. Prospective analysis of all lumbosacral MRI performed at King Abdullah University Hospital during a 21-month period. A total of 37 patients with LFT were included. Patients were divided into two groups. Group A patients have neurological deficit manifested by either motor, sensory or sphincter abnormality. Group B patients have normal neurological examination. Clinical findings were correlated with: A: thickness of LFT, B: length of LFT, C: distance of LFT from conus medullaris (CM), D: age of the patient. The prevalence of isolated LFT in our study was 3.2%. There was no significant correlation between the thickness or length of LFT and the presence of neurological deficit. The distance of LFT from CM was also not correlated with the patient clinical presentation. No significant difference in the age between the two groups. LFT in adult likely represent an incidental finding on routine lumbosacral MRI. Special attention for LFT in children is mandatory as it may indicate clinical tethering in otherwise normal appearing LSS.

  7. Fusion of PET and MRI for Hybrid Imaging

    Science.gov (United States)

    Cho, Zang-Hee; Son, Young-Don; Kim, Young-Bo; Yoo, Seung-Schik

    Recently, the development of the fusion PET-MRI system has been actively studied to meet the increasing demand for integrated molecular and anatomical imaging. MRI can provide detailed anatomical information on the brain, such as the locations of gray and white matter, blood vessels, axonal tracts with high resolution, while PET can measure molecular and genetic information, such as glucose metabolism, neurotransmitter-neuroreceptor binding and affinity, protein-protein interactions, and gene trafficking among biological tissues. State-of-the-art MRI systems, such as the 7.0 T whole-body MRI, now can visualize super-fine structures including neuronal bundles in the pons, fine blood vessels (such as lenticulostriate arteries) without invasive contrast agents, in vivo hippocampal substructures, and substantia nigra with excellent image contrast. High-resolution PET, known as High-Resolution Research Tomograph (HRRT), is a brain-dedicated system capable of imaging minute changes of chemicals, such as neurotransmitters and -receptors, with high spatial resolution and sensitivity. The synergistic power of the two, i.e., ultra high-resolution anatomical information offered by a 7.0 T MRI system combined with the high-sensitivity molecular information offered by HRRT-PET, will significantly elevate the level of our current understanding of the human brain, one of the most delicate, complex, and mysterious biological organs. This chapter introduces MRI, PET, and PET-MRI fusion system, and its algorithms are discussed in detail.

  8. Initial tests of a prototype MRI-compatible PET imager

    Energy Technology Data Exchange (ETDEWEB)

    Raylman, Raymond R. [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States)]. E-mail: rraylman@wvu.edu; Majewski, Stan [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Lemieux, Susan [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States); Velan, S. Sendhil [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States); Kross, Brain [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Popov, Vladimir [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Smith, Mark F. [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Weisenberger, Andrew G. [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Wojcik, Randy [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2006-12-20

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI, will allow the correlation of form with function. Our group (a collaboration of West Virginia University and Jefferson Lab) is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode with an active FOV of 5x5x4 cm{sup 3}. Each MRI-PET detector module consists of an array of LSO detector elements (2.5x2.5x15 mm{sup 3}) coupled through a long fiber optic light guide to a single Hamamatsu flat panel PSPMT. The fiber optic light guide is made of a glued assembly of 2 mm diameter acrylic fibers with a total length of 2.5 m. The use of a light guides allows the PSPMTs to be positioned outside the bore of the 3 T General Electric MRI scanner used in the tests. Photon attenuation in the light guides resulted in an energy resolution of {approx}60% FWHM, interaction of the magnetic field with PSPMT further reduced energy resolution to {approx}85% FWHM. Despite this effect, excellent multi-plane PET and MRI images of a simple disk phantom were acquired simultaneously. Future work includes improved light guides, optimized magnetic shielding for the PSPMTs, construction of specialized coils to permit high-resolution MRI imaging, and use of the system to perform simultaneous PET and MRI or MR-spectroscopy.

  9. Functional brain imaging - baric and clinical questions

    International Nuclear Information System (INIS)

    Mager, T.; Moeller, H.J.

    1997-01-01

    The advancing biological knowledge of disease processes plays a central part in the progress of modern psychiatry. An essential contribution comes from the functional and structural brain imaging techniques (CT, MRI, SPECT, PET). Their application is important for biological oriented research in psychiatry and there is also a growing relevance in clinical aspects. This development is taken into account by recent diagnostic classification systems in psychiatry. The capabilities and limitations of functional brain imaging in the context of research and clinic will be presented and discussed by examples and own investigations. (orig.) [de

  10. Imaging gait analysis: An fMRI dual task study.

    Science.gov (United States)

    Bürki, Céline N; Bridenbaugh, Stephanie A; Reinhardt, Julia; Stippich, Christoph; Kressig, Reto W; Blatow, Maria

    2017-08-01

    In geriatric clinical diagnostics, gait analysis with cognitive-motor dual tasking is used to predict fall risk and cognitive decline. To date, the neural correlates of cognitive-motor dual tasking processes are not fully understood. To investigate these underlying neural mechanisms, we designed an fMRI paradigm to reproduce the gait analysis. We tested the fMRI paradigm's feasibility in a substudy with fifteen young adults and assessed 31 healthy older adults in the main study. First, gait speed and variability were quantified using the GAITRite © electronic walkway. Then, participants lying in the MRI-scanner were stepping on pedals of an MRI-compatible stepping device used to imitate gait during functional imaging. In each session, participants performed cognitive and motor single tasks as well as cognitive-motor dual tasks. Behavioral results showed that the parameters of both gait analyses, GAITRite © and fMRI, were significantly positively correlated. FMRI results revealed significantly reduced brain activation during dual task compared to single task conditions. Functional ROI analysis showed that activation in the superior parietal lobe (SPL) decreased less from single to dual task condition than activation in primary motor cortex and in supplementary motor areas. Moreover, SPL activation was increased during dual tasks in subjects exhibiting lower stepping speed and lower executive control. We were able to simulate walking during functional imaging with valid results that reproduce those from the GAITRite © gait analysis. On the neural level, SPL seems to play a crucial role in cognitive-motor dual tasking and to be linked to divided attention processes, particularly when motor activity is involved.

  11. Visualization of pulmonary nodules with magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Plathow, C.; Deutsches Krebsforschungszentrum; Meinzer, H.-P.; Kauczor, H.-U.

    2006-01-01

    Visualization of pulmonary nodules using magnetic resonance imaging (MRI) plays a minor role compared with computed tomography (CT). Technical developments made it possible to apply MRI more and more frequently in functional imaging. Imaging of the motion of pulmonary nodules during respiration, e.g., to optimize high precision therapy techniques, is a new field of research. This paper describes developments in analysis and visualization of pulmonary nodules during respiration using MRI. Besides actual 2D techniques new 3D techniques to quantify motion of pulmonary nodules during respiration are presented. (orig.) [de

  12. MRI signal changes of the bone marrow in HIV-infected patients with lipodystrophy: correlation with clinical parameters

    International Nuclear Information System (INIS)

    Garcia, Ana I.; Tomas, Xavier; Pomes, Jaume; Amo, Montserrat del; Milinkovic, Ana; Perez, Inaki; Mallolas, Josep; Rios, Jose; Vidal-Sicart, Sergi

    2011-01-01

    To assess the prevalence, imaging appearance, and clinical significance, of bone marrow MR signal changes in a group of human immunodeficiency virus (HIV)-infected patients with lipodystrophy syndrome. Twenty-eight HIV-infected patients with lipodystrophy syndrome treated with highly active antiretroviral therapy, and 12 HIV-negative controls underwent MRI of the legs. Whole-body MRI, SPECT/CT, and a complete radiographic skeletal survey were obtained in subjects with signal changes in bone marrow. MRI and clinical evaluations were reviewed 6 months after baseline to determine changes after switching from thymidine analogs (TA) to tenofovir-DF (TDF). MRI results correlated with clinical parameters. We observed foci of a serous-like pattern (low signal and no enhancement on T1-weighted, high signal on T2-weighted images) in 4 out of 28 patients (14.3%) and an intermediate signal on T1-weighted images in 4 out of 28 patients (14.3%). Serous-like lesions were located in the lower limbs and scattered in the talus, calcaneus, femurs, and humeral bones; they showed slight uptake on SPECT bone scans and were normal on CT and radiographs. Patients with serous-like lesions had significantly lower peripheral and total fat at baseline than other groups (P < 0.05). No changes at 6 months were observed on MRI, and the serous-like lesion group showed good peripheral fat recovery after changing drug treatment. A serous-like MRI pattern is observed in the peripheral skeletons of HIV-infected patients with lipodystrophy, which correlates with peripheral lipoatrophy, and should not be misdiagnosed as malignant or infectious diseases. Although the MR lesions did not improve after switching the treatment, there was evidence of lipoatrophy recovery. (orig.)

  13. Imaging in the diagnosis and management of peripheral psoriatic arthritis-The clinical utility of magnetic resonance imaging and ultrasonography

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Eder, Lihi; Christiansen, Sara Nysom

    2016-01-01

    Psoriatic arthritis (PsA) is an inflammatory joint disease characterised by the presence of arthritis and often enthesitis and/or spondylitis in patients with psoriasis. However, it presents a wide range of disease manifestations in various patterns. Imaging is an important part of management of PsA...... or clinical studies. Magnetic resonance imaging (MRI) allows detailed assessment of all peripheral and axial joints involved in PsA, and can visualise both inflammation and structural changes. Ultrasonography (US) can visualise many of the peripheral heterogeneous tissue compartments affected by PsA....... In contrast to MRI, US is not useful for assessing axial involvement in the spine and sacroiliac joints. In this paper, we will provide an overview of the status, strengths and limitations of MRI and US in peripheral PsA in routine clinical practice and clinical trials....

  14. Clinical relevance of the apparent diffusion coefficient value of metastatic bone tumours on diffusion-weighted MRI images: differences according to the types of primary tumour, the affected bones, and clinical factors.

    Science.gov (United States)

    Cha, M J; Yoon, Y C

    2015-10-01

    To evaluate whether the apparent diffusion coefficient (ADC) of metastatic bone tumours on diffusion-weighted magnetic resonance imaging (MRI) images differs according to the type of primary cancer, the affected bone, and clinical factors. For this retrospective study, two radiologists reviewed MRI images, including ADC maps, of 67 patients (M:F=38:29; median age, 48 years) who were diagnosed with bone metastasis by means of histological or clinical confirmation. The primary tumours included 29 lung adenocarcinomas, 15 invasive ductal adenocarcinomas of the breast, 13 hepatocellular carcinomas, six prostatic carcinomas, and four renal cell carcinomas. ADC values of the metastatic tumour were compared according to the type of primary malignancy, the affected bone, and the age and sex of the patient using Kruskal-Wallis and Mann-Whitney U-tests with Bonferroni correction. In addition, pre-contrast CT images were available in 38 of 67 patients; a subanalysis of the CT radiodensity and ADC values were performed with Spearman correlation. The mean, standard deviation, and minimum and maximum values of the ADC of metastatic bone tumours did not differ significantly according to type of primary malignancy, the affected bone, or clinical variables (p>0.1). The ADC value was not significantly correlated with CT radiodensity (p=0.24). Intra- and interobserver agreements for the mean ADC values were excellent (intra-observer: p=0.98; interobserver: p=0.98). Assessment of the ADC value of metastatic bone tumours is not reliable for differentiation of the type of primary cancer. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  15. Fetal lung volume measurement by MRI with high-speed imaging systems

    Energy Technology Data Exchange (ETDEWEB)

    Osada, Hisao; Kaku, Kenshi [Chiba Univ. (Japan). Hospital

    2002-08-01

    Although ultrasonography is widely used for fetal morphologic observation, magnetic resonance imaging (MRI) has gained popularity as a new prenatal diagnostic method with recent introduction of high-speed imaging systems. Infants with lung hypoplasia affecting respiratory function require intensive management starting immediately after birth. Therefore, accurate prenatal differential diagnosis and severity evaluation are extremely important for these fetuses. The aim of this study is to measure fetal lung volume using a computer-based, three-dimensional MRI imaging system and to evaluate the possibility of clinical applications of this procedure. A total of 96 fetuses were evaluated, all were morphologically abnormal, and MRI was done for advanced assessment from 24 to 39 weeks gestation. Three-directional views of fetal chest were imaged by Signa Horizon, 1.5 Tesla, version 5.6 (General Electronics) with the following conditions; coil: TORSO coil, sequence: SSFSE (single shot fast spin echo), slice thickness: 5 mm, and imaging speed: 2 seconds/slice. To calculate the lung volume and create three-dimensional image, the lung area in each slice was traced out, then multiplied using computer image processing. Simultaneously, the volumes of all slices were summed to give the volume of each lung. Linear regression analysis and analysis of covariance (ANCOVA) were used for statistical analyses. In all cases, clear images were obtained, and were adequate for three-dimensional evaluation of the fetal lung. Thirty-five fetuses had poor outcomes, such as intrauterine fetal death, neonatal death, and intensive respiratory care. Regression lines of lung volume versus gestational week were calculated for these fetuses with poor outcome and 61 other fetuses with good outcome. ANCOVA, with gestational week as a covariant, revealed a significant intergroup difference in the lung volume (p<0.001). Similarly, regression lines of lung volume versus fetal body weight estimated by

  16. Molecular imaging of head and neck cancers. Perspectives of PET/MRI

    International Nuclear Information System (INIS)

    Stumpp, P.; Kahn, T.; Purz, S.; Sabri, O.

    2016-01-01

    The 18 F-fluorodeoxyglucose positron emission tomography-computed tomography ( 18 F-FDG-PET/CT) procedure is a cornerstone in the diagnostics of head and neck cancers. Several years ago PET-magnetic resonance imaging (PET/MRI) also became available as an alternative hybrid multimodal imaging method. Does PET/MRI have advantages over PET/CT in the diagnostics of head and neck cancers ?The diagnostic accuracy of the standard imaging methods CT, MRI and PET/CT is depicted according to currently available meta-analyses and studies concerning the use of PET/MRI for these indications are summarized. In all studies published up to now PET/MRI did not show superiority regarding the diagnostic accuracy in head and neck cancers; however, there is some evidence that in the future PET/MRI can contribute to tumor characterization and possibly be used to predict tumor response to therapy with the use of multiparametric imaging. Currently, 18 F-FDG-PET/CT is not outperformed by PET/MRI in the diagnostics of head and neck cancers. The additive value of PET/MRI due to the use of multiparametric imaging needs to be investigated in future research. (orig.) [de

  17. Magnetic resonance imaging goes postmortem: noninvasive detection and assessment of myocardial infarction by postmortem MRI

    International Nuclear Information System (INIS)

    Jackowski, Christian; Warntjes, Marcel J.B.; Persson, Anders; Berge, Johan; Baer, Walter

    2011-01-01

    To investigate the performance of postmortem magnetic resonance imaging (pmMRI) in identification and characterization of lethal myocardial infarction in a non-invasive manner on human corpses. Before forensic autopsy, 20 human forensic corpses were examined on a 1.5-T system for the presence of myocardial infarction. Short axis, transversal and longitudinal long axis images (T1-weighted; T2-weighted; PD-weighted) were acquired in situ. In subsequent autopsy, the section technique was adapted to short axis images. Histological investigations were conducted to confirm autopsy and/or radiological diagnoses. Nineteen myocardial lesions were detected and age staged with pmMRI, of which 13 were histologically confirmed (chronic, subacute and acute). Six lesions interpreted as peracute by pmMRI showed no macroscopic or histological finding. Five of the six peracute lesions correlated well to coronary pathology, and one case displayed a severe hypertrophic alteration. pmMRI reliably demonstrates chronic, subacute and acute myocardial infarction in situ. In peracute cases pmMRI may display ischemic lesions undetectable at autopsy and routine histology. pmMRI has the potential to substantiate autopsy and to counteract the loss of reliable information on causes of death due to the recent disappearance of the clinical autopsy. (orig.)

  18. The registration accuracy analysis of different CT-MRI imaging fusion method in brain tumor

    International Nuclear Information System (INIS)

    Lu Jie; Yin Yong; Shao Qian; Zhang Zicheng; Chen Jinhu; Chen Zhaoqiu

    2010-01-01

    Objective: To find an effective CT-MRI image fusion protocol in brain tumor by analyzing the registration accuracy of different methods. Methods: The simulation CT scan and MRI T 1 WI imaging of 10 brain tumor patients obtained with same position were registered by Tris-Axes landmark ,Tris-Axes landmark + manual adjustment, mutual information and mutual information + manual adjustment method. The clinical tumor volume (CTV) were contoured on both CT and MRI images respectively. The accuracy of image fusion was assessed by the mean distance of five bone markers (d 1-5 ), central position of CTV (d CTV ) the percentage of CTV overlap (P CT-MRI ) between CT and MRI images. The difference between different methods was analyzed by Freedman M non-parameter test. Results: The difference of the means d1-5 between the Tris-Axes landmark,Tris-Axes landmark plus manual adjustment,mutual information and mutual information plus manual adjustment methods were 0.28 cm ±0.12 cm, 0.15 cm ±0.02 cm, 0.25 cm± 0.19 cm, 0.10 cm ± 0.06 cm, (M = 14.41, P = 0.002). the means d CTV were 0.59 cm ± 0.28 cm, 0.60 cm± 0.32 cm, 0.58 cm ± 0.39 cm, 0.42 cm± 0.30 cm (M = 9.72, P = 0.021), the means P CT-MRI were 0.69% ±0.18%, 0.68% ±0.16%, 0.66% ±0.17%, 0.74% ±0.14% (M =14.82, P=0.002), respectively. Conclusions: Mutual information plus manual adjustment registration method was the preferable fusion method for brain tumor patients. (authors)

  19. Clinical application of MRI to fetal central nervous system

    International Nuclear Information System (INIS)

    Wang Guangbing; Chen Liguang; Ma Yuxiang; Liu Wen; Lin Xiangtao; Shi Hao; Yang Zhenzhen; Qu Jun

    2005-01-01

    Objective: To explore the value of MRI on fetal central nervous system. Methods: Twenty-four women with complicated pregnancies, aged from 22 to 32 years (average 27 years) and with gestation from 23-39 weeks (average 30 weeks) were studied with a 1.5T superconductive MR unit within 24 hours after ultrasound studies. T 2 -weighted MR imaging was performed using HASTE and T 1 -weighted MR imaging was using FLASH. Comparison of the diagnosis of MRI and ultrasound were done with autopsy or postnatal follow-up MRI. Results: Of the 24 cases, 24 fetus were found. The fetal brain, gyrus, sulcus, corpus callosum, thalamus, cerebellum, brain stem, and spinal cord were shown more clearly on MR T 2 -weighted images. T 1 -weighted images were not as good as T 2 -weighted images. Twenty-seven lesions were visualized by ultrasound and thirty-one by MRI in these twenty-four fetuses. By MRI study, two cases were conformed their ultrasound diagnosis, ten cases were completed their ultrasound diagnosis, and twelve cases were made the same diagnosis as ultrasound. Conclusion: MR has advantages in displaying fetal central nervous system anatomy over ultrasound, the quality of MR images is not affected by maternal somatotype, volume of amniotic fluid, fetal skull and the pelvic skeleton of pregnant women. Based on ultrasound, MR imaging is a valuable complement to sonography in difficult cases, it can conforming, completing, even more correcting the diagnosis made by ultrasound. (authors)

  20. PET/MRI in cancer patients

    DEFF Research Database (Denmark)

    Kjær, Andreas; Loft, Annika; Law, Ian

    2013-01-01

    Combined PET/MRI systems are now commercially available and are expected to change the medical imaging field by providing combined anato-metabolic image information. We believe this will be of particular relevance in imaging of cancer patients. At the Department of Clinical Physiology, Nuclear...... described include brain tumors, pediatric oncology as well as lung, abdominal and pelvic cancer. In general the cases show that PET/MRI performs well in all these types of cancer when compared to PET/CT. However, future large-scale clinical studies are needed to establish when to use PET/MRI. We envision...... that PET/MRI in oncology will prove to become a valuable addition to PET/CT in diagnosing, tailoring and monitoring cancer therapy in selected patient populations....

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... information please consult the ACR Manual on Contrast Media and its references. top of page What are the limitations of MRI of the Head? High-quality images are assured only if you are able to ...

  2. Comprehensive MRI simulation methodology using a dedicated MRI scanner in radiation oncology for external beam radiation treatment planning

    International Nuclear Information System (INIS)

    Paulson, Eric S.; Erickson, Beth; Schultz, Chris; Allen Li, X.

    2015-01-01

    Purpose: The use of magnetic resonance imaging (MRI) in radiation oncology is expanding rapidly, and more clinics are integrating MRI into their radiation therapy workflows. However, radiation therapy presents a new set of challenges and places additional constraints on MRI compared to diagnostic radiology that, if not properly addressed, can undermine the advantages MRI offers for radiation treatment planning (RTP). The authors introduce here strategies to manage several challenges of using MRI for virtual simulation in external beam RTP. Methods: A total of 810 clinical MRI simulation exams were performed using a dedicated MRI scanner for external beam RTP of brain, breast, cervix, head and neck, liver, pancreas, prostate, and sarcoma cancers. Patients were imaged in treatment position using MRI-optimal immobilization devices. Radiofrequency (RF) coil configurations and scan protocols were optimized based on RTP constraints. Off-resonance and gradient nonlinearity-induced geometric distortions were minimized or corrected prior to using images for RTP. A multidisciplinary MRI simulation guide, along with window width and level presets, was created to standardize use of MR images during RTP. A quality assurance program was implemented to maintain accuracy and repeatability of MRI simulation exams. Results: The combination of a large bore scanner, high field strength, and circumferentially wrapped, flexible phased array RF receive coils permitted acquisition of thin slice images with high contrast-to-noise ratio (CNR) and image intensity uniformity, while simultaneously accommodating patient setup and immobilization devices. Postprocessing corrections and alternative acquisition methods were required to reduce or correct off-resonance and gradient nonlinearity induced geometric distortions. Conclusions: The methodology described herein contains practical strategies the authors have implemented through lessons learned performing clinical MRI simulation exams. In

  3. Comprehensive MRI simulation methodology using a dedicated MRI scanner in radiation oncology for external beam radiation treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Paulson, Eric S., E-mail: epaulson@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 and Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 (United States); Erickson, Beth; Schultz, Chris; Allen Li, X. [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 (United States)

    2015-01-15

    Purpose: The use of magnetic resonance imaging (MRI) in radiation oncology is expanding rapidly, and more clinics are integrating MRI into their radiation therapy workflows. However, radiation therapy presents a new set of challenges and places additional constraints on MRI compared to diagnostic radiology that, if not properly addressed, can undermine the advantages MRI offers for radiation treatment planning (RTP). The authors introduce here strategies to manage several challenges of using MRI for virtual simulation in external beam RTP. Methods: A total of 810 clinical MRI simulation exams were performed using a dedicated MRI scanner for external beam RTP of brain, breast, cervix, head and neck, liver, pancreas, prostate, and sarcoma cancers. Patients were imaged in treatment position using MRI-optimal immobilization devices. Radiofrequency (RF) coil configurations and scan protocols were optimized based on RTP constraints. Off-resonance and gradient nonlinearity-induced geometric distortions were minimized or corrected prior to using images for RTP. A multidisciplinary MRI simulation guide, along with window width and level presets, was created to standardize use of MR images during RTP. A quality assurance program was implemented to maintain accuracy and repeatability of MRI simulation exams. Results: The combination of a large bore scanner, high field strength, and circumferentially wrapped, flexible phased array RF receive coils permitted acquisition of thin slice images with high contrast-to-noise ratio (CNR) and image intensity uniformity, while simultaneously accommodating patient setup and immobilization devices. Postprocessing corrections and alternative acquisition methods were required to reduce or correct off-resonance and gradient nonlinearity induced geometric distortions. Conclusions: The methodology described herein contains practical strategies the authors have implemented through lessons learned performing clinical MRI simulation exams. In

  4. Whole-body MRI, dynamic contrast-enhanced MRI, and diffusion-weighted imaging for the staging of multiple myeloma

    Energy Technology Data Exchange (ETDEWEB)

    Dutoit, Julie C.; Verstraete, Koenraad L. [Ghent University Hospital, Department of Radiology, Ghent (Belgium)

    2017-06-15

    Magnetic resonance imaging (MRI) is the most sensitive imaging technique for the detection of bone marrow infiltration, and has therefore recently been included in the new diagnostic myeloma criteria, as proposed by the International Myeloma Working Group. Nevertheless, conventional MRI only provides anatomical information and is therefore only of limited use in the response assessment of patients with multiple myeloma. The additional information from functional MRI techniques, such as diffusion-weighted imaging and dynamic contrast-enhanced MRI, can improve the detection rate of bone marrow infiltration and the assessment of response. This can further enhance the sensitivity and specificity of MRI in the staging of multiple myeloma patients. This article provides an overview of the technical aspects of conventional and functional MRI techniques with practical recommendations. It reviews the diagnostic performance, prognostic value, and role in therapy assessment in multiple myeloma and its precursor stages. (orig.)

  5. Motor programme activating therapy influences adaptive brain functions in multiple sclerosis: clinical and MRI study.

    Science.gov (United States)

    Rasova, Kamila; Prochazkova, Marie; Tintera, Jaroslav; Ibrahim, Ibrahim; Zimova, Denisa; Stetkarova, Ivana

    2015-03-01

    There is still little scientific evidence for the efficacy of neurofacilitation approaches and their possible influence on brain plasticity and adaptability. In this study, the outcome of a new kind of neurofacilitation approach, motor programme activating therapy (MPAT), was evaluated on the basis of a set of clinical functions and with MRI. Eighteen patients were examined four times with standardized clinical tests and diffusion tensor imaging to monitor changes without therapy, immediately after therapy and 1 month after therapy. Moreover, the strength of effective connectivity was analysed before and after therapy. Patients underwent a 1-h session of MPAT twice a week for 2 months. The data were analysed by nonparametric tests of association and were subsequently statistically evaluated. The therapy led to significant improvement in clinical functions, significant increment of fractional anisotropy and significant decrement of mean diffusivity, and decrement of effective connectivity at supplementary motor areas was observed immediately after the therapy. Changes in clinical functions and diffusion tensor images persisted 1 month after completing the programme. No statistically significant changes in clinical functions and no differences in MRI-diffusion tensor images were observed without physiotherapy. Positive immediate and long-term effects of MPAT on clinical and brain functions, as well as brain microstructure, were confirmed.

  6. Turbulent Kinetic Energy Measurement Using Phase Contrast MRI for Estimating the Post-Stenotic Pressure Drop: In Vitro Validation and Clinical Application.

    Directory of Open Access Journals (Sweden)

    Hojin Ha

    Full Text Available Although the measurement of turbulence kinetic energy (TKE by using magnetic resonance imaging (MRI has been introduced as an alternative index for quantifying energy loss through the cardiac valve, experimental verification and clinical application of this parameter are still required.The goal of this study is to verify MRI measurements of TKE by using a phantom stenosis with particle image velocimetry (PIV as the reference standard. In addition, the feasibility of measuring TKE with MRI is explored.MRI measurements of TKE through a phantom stenosis was performed by using clinical 3T MRI scanner. The MRI measurements were verified experimentally by using PIV as the reference standard. In vivo application of MRI-driven TKE was explored in seven patients with aortic valve disease and one healthy volunteer. Transvalvular gradients measured by MRI and echocardiography were compared.MRI and PIV measurements of TKE are consistent for turbulent flow (0.666 400. The turbulence pressure drop correlates strongly with total TKE (R2 = 0.986. However, in vivo measurements of TKE are not consistent with the transvalvular pressure gradient estimated by echocardiography.These results suggest that TKE measurement via MRI may provide a potential benefit as an energy-loss index to characterize blood flow through the aortic valve. However, further clinical studies are necessary to reach definitive conclusions regarding this technique.

  7. Heroin-induced leukoencephalopathy: characterization using MRI, diffusion-weighted imaging, and MR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Offiah, C. [Department of Neuroradiology, St Bartholomew' s and the London Hospitals NHS Trust, London (United Kingdom); Hall, E. [Department of Neuroradiology, St Bartholomew' s and the London Hospitals NHS Trust, London (United Kingdom)], E-mail: curtis.offiah@bartsandthelondon.nhs.uk

    2008-02-15

    Aim: To describe the magnetic resonance imaging (MRI) characteristics of heroin-induced leukoencephalopathy or 'chasing the dragon syndrome' and, in particular, the diffusion-weighted imaging (DWI) and MR spectroscopy (MRS) features. Material and methods: Six patients with a clinical or histopathological diagnosis of heroin-induced leukoencephalopathy were identified and MRI examinations, including DWI and single-voxel MRS, reviewed. Results: Cerebellar white matter was involved in all six cases demonstrating similar symmetrical distribution with sparing of the dentate nuclei. Brain stem signal change was evident in five of the six patients imaged. Supratentorial brain parenchymal involvement, as well as brain stem involvement, correlated anatomically with corticospinal tract distribution. None of the areas of signal abnormality were restricted on DWI. Of those patients subjected to MRS, the areas of parenchymal damage demonstrated reduced N-acetylaspartate, reduced choline, and elevated lactate. Conclusion: Heroin-induced leukoencephalopathy results in characteristic and highly specific signal abnormalities on MRI, which can greatly aid diagnosis. DWI and MRS findings can be explained by known reported neuropathological descriptions in this condition and can be used to support a proposed mechanism for the benefit of current recommended drug treatment regimes.

  8. FY1995 report on the novel methods for magnetic resonance imaging; 1995 nendo senshin MRI gazoka shuho no kiso kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The purpose of this project is to develop new 2-dimensional ultrafast MRI (Magnetic Resonance Imaging) methods for the Image Guided Cancer Therapy (IGT) and the non-invasive clinical diagnosis. We have developed two MRI methods. They can reconstruct a two dimensional image by only a RF excitation and slow changing of gradient fields. This paper describes theoretically how to apply the RF wave and the gradient in x, y and z direction, respectively. Echo signals are acquired under multi-frequency resonance. The frequency bandwidth of the RF wave adjusts the field of view (FOV) of the imaging plane. Biological effects of the applied RF wave was evaluated by the brain microdialysis. In animal experiments, these was not significant change of neurotransmitters subject to the RF wave. From these theoretical and experimental results, these MRI methods are applicable to IGT and the clinical diagnosis for the cancer and other diseases. (NEDO)

  9. Optimizing imaging in suspected appendicitis (OPTIMAP-study: A multicenter diagnostic accuracy study of MRI in patients with suspected acute appendicitis. Study Protocol

    Directory of Open Access Journals (Sweden)

    Bossuyt Patrick MM

    2010-10-01

    Full Text Available Abstract Background In patients with clinically suspected appendicitis, imaging is needed to substantiate the clinical diagnosis. Imaging accuracy of ultrasonography (US is suboptimal, while the most accurate technique (CT is associated with cancer related deaths through exposure to ionizing radiation. MRI is a potential replacement, without associated ionizing radiation and no need for contrast medium administration. If MRI is proven to be sufficiently accurate, it could be introduced in the diagnostic pathway of patients with suspected appendicitis, increasing diagnostic accuracy and improving clinical outcomes, without the risk of radiation induced cancer or iodinated contrast medium-related drawbacks. The multicenter OPTIMAP study was designed to estimate the diagnostic accuracy of MRI in patients with suspected acute appendicitis in the general population. Methods/Design Eligible for this study are consecutive patients presenting with clinically suspected appendicitis at the emergency department in six centers. All patients will undergo imaging according to the Dutch guideline for acute appendicitis: initial ultrasonography in all and subsequent CT whenever US does not confirm acute appendicitis. Then MRI is performed in all patients, but the results are not used for patient management. A final diagnosis assigned by an expert panel, based on all available information including 3-months follow-up, except MRI findings, is used as the reference standard in estimating accuracy. We will calculate the sensitivity, specificity, predictive values and inter-observer agreement of MRI, and aim to include 230 patients. Patient acceptance and total imaging costs will also be evaluated. Discussion If MRI is found to be sufficiently accurate, it could replace CT in some or all patients. This will limit or obviate the ionizing radiation exposure associated risk of cancer induction and contrast medium induced nephropathy with CT, preventing the burden and

  10. Imaging vascular function for early stage clinical trials using dynamic contrast-enhanced magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Leach, M.O.; Orton, M. [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Cancer Research UK and EPSRC Cancer Imaging Centre, Sutton, Surrey (United Kingdom); Morgan, B. [Univ. of Leicester, College of Medicine, Biological Sciences and Psychology, Leicester (United Kingdom); Tofts, P.S. [Brighton and Sussex Medical School, Univ. of Sussex, Clinical Imaging Sciences Centre, Sussex (United Kingdom); Buckley, D.L. [University of Leeds, Division of Medical Physics, Leeds (United Kingdom); Huang, W. [Oregon Health and Science Univ., Advanced Imaging Research Centre, Portland, OR (United States); Horsfield, M.A. [Medical Physics Section, Leicester Royal Infirmary, Dept. of Cardiovascular Sciences, Leicester (United Kingdom); Chenevert, T.L. [Univ. of Michigan Health System, Ann Arbor, MI (United States); Collins, D.J. [Royal Marsden Hospital NHS Foundation Trust, Cancer Research UK and EPSRC Cancer Imaging Centre, Sutton, Surrey (United Kingdom); Jackson, A. [Univ. of Manchester, Wolfson Molecular Imaging Centre, Withington, Manchester, M20 3LJ (United Kingdom); Lomas, D. [Univ. of Cambridge, Dept. of Radiology, Cambridge (United Kingdom); Whitcher, B. [Unit 2 Greenways Business Park, Mango Solutions, Chippenham (United Kingdom); Clarke, L. [Cancer Imaging Program, Imaging Technology Development Branch, Rockville, MD (United States); Plummer, R. [Univ. of Newcastle Upon Tyne, The Medical School, Medical Oncology, Northern Inst. for Cancer Research, Newcastle Upon Tyne (United Kingdom); Judson, I. [Royal Marsden Hospital, Sutton, Surrey (United Kingdom); Jones, R. [Beatson West of Scotland Cancer Centre, Glasgow (United Kingdom); Alonzi, R. [Mount Vernon Cancer Centre, Northwood (United Kingdom); Brunner, T. [Gray Inst. for Radiation, Oncology and Biology, Oxford (United Kingdom); Koh, D.M. [Royal Marsden NHS Foundation Trust, Diagnostic Radiology, Sutton, Surrey (United Kingdom)] [and others

    2012-07-15

    Many therapeutic approaches to cancer affect the tumour vasculature, either indirectly or as a direct target. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has become an important means of investigating this action, both pre-clinically and in early stage clinical trials. For such trials, it is essential that the measurement process (i.e. image acquisition and analysis) can be performed effectively and with consistency among contributing centres. As the technique continues to develop in order to provide potential improvements in sensitivity and physiological relevance, there is considerable scope for between-centre variation in techniques. A workshop was convened by the Imaging Committee of the Experimental Cancer Medicine Centres (ECMC) to review the current status of DCE-MRI and to provide recommendations on how the technique can best be used for early stage trials. This review and the consequent recommendations are summarised here. (orig.)

  11. Multimodality imaging: transfer and fusion of SPECT and MRI data

    International Nuclear Information System (INIS)

    Knesaurek, K.

    1994-01-01

    Image fusion is a technique which offers the best of both worlds. It unites the two basic types of medical images: functional body images(PET or SPECT scans), which provide physiological information, and structural images (CT or MRI), which provide an anatomic map of the body. Control-point based registration technique was developed and used. Tc-99m point sources were used as external markers in SPECT studies while, for MRI and CT imaging only anatomic landmarks were used as a control points. The MRI images were acquired on GE Signa 1.2 system and CT data on a GE 9800 scanner. SPECT studies were performed 1h after intravenous injection of the 740 MBq of the Tc-99m-HMPAO on the triple-headed TRIONIX gamma camera. B-spline and bilinear interpolation were used for the rotation, scaling and translation of the images. In the process of creation of a single composite image, in order to retain information from the individual images, MRI (or CT) image was scaled to one color range and a SPECT image to another. In some situations the MRI image was kept black-and-white while the SPECT image was pasted on top of it in 'opaque' mode. Most errors which propagate through the matching process are due to sample size, imperfection of the acquisition system, noise and interpolations used. Accuracy of the registration was investigated by SPECT-CT study performed on a phantom study. The results has shown that accuracy of the matching process is better, or at worse, equal to 2 mm. (author)

  12. Evaluation of the TMJ by means of Clinical TMD Examination and MRI Diagnostics in Patients with Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Silke Witulski

    2014-01-01

    Full Text Available This study included 30 patients with diagnosed rheumatoid arthritis (RA and 30 test subjects without RA (control group. The objective of the study was to examine both groups for the presence of temporomandibular disorders (TMD and morphological changes of the temporomandibular joint (TMJ. All individuals were examined using a systematic detailed clinical TMD examination as well as magnetic resonance imaging (MRI. The clinical TMD examination yielded significant differences between the RA patients and the control group concerning crepitus of the TMJ, and palpation tenderness of the masticatory muscles as well as the unassisted mandibular opening. The evaluation of the MRI images for the RA group showed significantly more frequent deformations of the condyle, osteophyte formations and erosions in the condylar compacta, and degenerative changes in the spongiosa. Increased intra-articular accumulation of synovial liquid and signs of inflammatory changes of the spongiosa were only found in the RA group. Statistical analysis showed a significant correlation between crepitus and specific osteoarthrotic changes (MRI, respectively, and between crepitus and a complete anterior disk displacement without reduction (MRI. The duration of the RA disease correlated neither with the anamnestic and clinical dysfunction index by Helkimo nor with RA-specific MRI findings.

  13. Cerebral and spinal MRI examination in patients with clinically isolated syndrome and definite multiple sclerosis

    International Nuclear Information System (INIS)

    Sailer, M.; Fazekas, F.; Gass, A.; Kappos, L.; Radue, E.W.; Rieckmann, P.; Toyka, K.; Wiendl, H.; Bendszus, M.

    2008-01-01

    Purpose: magnetic resonance imaging (MRI) has become a valuable tool for diagnosing and monitoring multiple sclerosis (MS). The high sensitivity for the detection of hyperintense lesions in T2-weighted scans contributes substantially to diagnosis. The initial lesion number or lesion volume stands for an increased probability of further accumulation of lesion burden, an earlier conversion to clinically definite MS and progression of disability in the next 5-15 years. This diagnostic and prognostic information gained from MRI early in the disease course lead in 2001 to a revision of the diagnostic criteria. Materials and methods: for the first time MRI criteria were defined in addition to the clinical and paraclinical criteria using the clinical terms for dissemination with respect to space and time. In particular, the defined MRI criteria are based on lesion number and location, the appearance of new lesions and lesion enhancement using contrast agent. Results: reliable detection and description of older and new lesions in the disease course by MRI represents subclinical disease activity which can substitute the clinical confirmation of a relapse leading to an earlier diagnosis. This places importance on the assessment of the subclinical disease activity in sequential MR scans requiring a standardized and reproducible approach to minimize variability despite different MR scanners. (orig.)

  14. Quantitative estimation of brain atrophy and function with PET and MRI two-dimensional projection images

    International Nuclear Information System (INIS)

    Saito, Reiko; Uemura, Koji; Uchiyama, Akihiko; Toyama, Hinako; Ishii, Kenji; Senda, Michio

    2001-01-01

    The purpose of this paper is to estimate the extent of atrophy and the decline in brain function objectively and quantitatively. Two-dimensional (2D) projection images of three-dimensional (3D) transaxial images of positron emission tomography (PET) and magnetic resonance imaging (MRI) were made by means of the Mollweide method which keeps the area of the brain surface. A correlation image was generated between 2D projection images of MRI and cerebral blood flow (CBF) or 18 F-fluorodeoxyglucose (FDG) PET images and the sulcus was extracted from the correlation image clustered by K-means method. Furthermore, the extent of atrophy was evaluated from the extracted sulcus on 2D-projection MRI and the cerebral cortical function such as blood flow or glucose metabolic rate was assessed in the cortex excluding sulcus on 2D-projection PET image, and then the relationship between the cerebral atrophy and function was evaluated. This method was applied to the two groups, the young and the aged normal subjects, and the relationship between the age and the rate of atrophy or the cerebral blood flow was investigated. This method was also applied to FDG-PET and MRI studies in the normal controls and in patients with corticobasal degeneration. The mean rate of atrophy in the aged group was found to be higher than that in the young. The mean value and the variance of the cerebral blood flow for the young are greater than those of the aged. The sulci were similarly extracted using either CBF or FDG PET images. The purposed method using 2-D projection images of MRI and PET is clinically useful for quantitative assessment of atrophic change and functional disorder of cerebral cortex. (author)

  15. Translating state-of-the-art spinal cord MRI techniques to clinical use: A systematic review of clinical studies utilizing DTI, MT, MWF, MRS, and fMRI

    Directory of Open Access Journals (Sweden)

    Allan R. Martin

    2016-01-01

    Conclusions: State-of-the-art spinal cord MRI techniques are emerging with great potential to improve the diagnosis and management of various spinal pathologies, but the current body of evidence has only showed limited clinical utility to date. Among these imaging tools DTI is the most mature, but further work is necessary to standardize and validate its use before it will be adopted in the clinical realm. Large, well-designed studies with a priori hypotheses, standardized acquisition methods, detailed clinical data collection, and robust automated analysis techniques are needed to fully demonstrate the potential of these rapidly evolving techniques.

  16. The usefulness of brain MRI and CT in the clinical practice of epilepsia

    Energy Technology Data Exchange (ETDEWEB)

    Horita, Hideki [Jikei Univ., Komae, Tokyo (Japan). Daisan Hospital; Maekawa, Kihei

    1995-09-01

    This study was conducted to clarify the usefulness of brain MRI and CT in the clinical practice of epilepsy. The subjects were 100 epileptic child patients (average age, 13.2{+-}8.2 years) who underwent brain MRI, including 93 patients who also underwent brain CT. Twenty-two abnormal findings were obtained by MRI and 25 by CT. Thirty-nine patients who had complications such as mental retardation, cerebral palsy, or the overlapping disorders showed abnormal findings in a significantly high incidence. No significant correlations existed between the presence or absence of abnormal findings and the disease course after seizures. Patients with symptomatic localization-related epilepsies or cryptogenic and symptomatic generalized epilepsies showed abnormal findings in a significantly high incidence and unfavorable disease course after seizures. In 10 of 28 patients who showed abnormal findings, the abnormal finding site on images were correlated to the focus site on electroencephalograms. In conclusion, brain MRI and CT are essential in the clinical practice of epilepsy, however, we should notice the limitation of these methods. (Y.S.).

  17. The usefulness of brain MRI and CT in the clinical practice of epilepsia

    International Nuclear Information System (INIS)

    Horita, Hideki; Maekawa, Kihei.

    1995-01-01

    This study was conducted to clarify the usefulness of brain MRI and CT in the clinical practice of epilepsy. The subjects were 100 epileptic child patients (average age, 13.2±8.2 years) who underwent brain MRI, including 93 patients who also underwent brain CT. Twenty-two abnormal findings were obtained by MRI and 25 by CT. Thirty-nine patients who had complications such as mental retardation, cerebral palsy, or the overlapping disorders showed abnormal findings in a significantly high incidence. No significant correlations existed between the presence or absence of abnormal findings and the disease course after seizures. Patients with symptomatic localization-related epilepsies or cryptogenic and symptomatic generalized epilepsies showed abnormal findings in a significantly high incidence and unfavorable disease course after seizures. In 10 of 28 patients who showed abnormal findings, the abnormal finding site on images were correlated to the focus site on electroencephalograms. In conclusion, brain MRI and CT are essential in the clinical practice of epilepsy, however, we should notice the limitation of these methods. (Y.S.)

  18. Wavelet-space correlation imaging for high-speed MRI without motion monitoring or data segmentation.

    Science.gov (United States)

    Li, Yu; Wang, Hui; Tkach, Jean; Roach, David; Woods, Jason; Dumoulin, Charles

    2015-12-01

    This study aims to (i) develop a new high-speed MRI approach by implementing correlation imaging in wavelet-space, and (ii) demonstrate the ability of wavelet-space correlation imaging to image human anatomy with involuntary or physiological motion. Correlation imaging is a high-speed MRI framework in which image reconstruction relies on quantification of data correlation. The presented work integrates correlation imaging with a wavelet transform technique developed originally in the field of signal and image processing. This provides a new high-speed MRI approach to motion-free data collection without motion monitoring or data segmentation. The new approach, called "wavelet-space correlation imaging", is investigated in brain imaging with involuntary motion and chest imaging with free-breathing. Wavelet-space correlation imaging can exceed the speed limit of conventional parallel imaging methods. Using this approach with high acceleration factors (6 for brain MRI, 16 for cardiac MRI, and 8 for lung MRI), motion-free images can be generated in static brain MRI with involuntary motion and nonsegmented dynamic cardiac/lung MRI with free-breathing. Wavelet-space correlation imaging enables high-speed MRI in the presence of involuntary motion or physiological dynamics without motion monitoring or data segmentation. © 2014 Wiley Periodicals, Inc.

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of the brain and other cranial structures are clearer and more detailed than with other ...

  20. Measurement of Strain in the Left Ventricle during Diastole withcine-MRI and Deformable Image Registration

    Energy Technology Data Exchange (ETDEWEB)

    Veress, Alexander I.; Gullberg, Grant T.; Weiss, Jeffrey A.

    2005-07-20

    The assessment of regional heart wall motion (local strain) can localize ischemic myocardial disease, evaluate myocardial viability and identify impaired cardiac function due to hypertrophic or dilated cardiomyopathies. The objectives of this research were to develop and validate a technique known as Hyperelastic Warping for the measurement of local strains in the left ventricle from clinical cine-MRI image datasets. The technique uses differences in image intensities between template (reference) and target (loaded) image datasets to generate a body force that deforms a finite element (FE) representation of the template so that it registers with the target image. To validate the technique, MRI image datasets representing two deformation states of a left ventricle were created such that the deformation map between the states represented in the images was known. A beginning diastoliccine-MRI image dataset from a normal human subject was defined as the template. A second image dataset (target) was created by mapping the template image using the deformation results obtained from a forward FE model of diastolic filling. Fiber stretch and strain predictions from Hyperelastic Warping showed good agreement with those of the forward solution. The technique had low sensitivity to changes in material parameters, with the exception of changes in bulk modulus of the material. The use of an isotropic hyperelastic constitutive model in the Warping analyses degraded the predictions of fiber stretch. Results were unaffected by simulated noise down to an SNR of 4.0. This study demonstrates that Warping in conjunction with cine-MRI imaging can be used to determine local ventricular strains during diastole.

  1. Simultaneous PET/MR imaging of the brain: feasibility of cerebral blood flow measurements with FAIR-TrueFISP arterial spin labeling MRI.

    Science.gov (United States)

    Stegger, Lars; Martirosian, Petros; Schwenzer, Nina; Bisdas, Sotirios; Kolb, Armin; Pfannenberg, Christina; Claussen, Claus D; Pichler, Bernd; Schick, Fritz; Boss, Andreas

    2012-11-01

    Hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) with simultaneous data acquisition promises a comprehensive evaluation of cerebral pathophysiology on a molecular, anatomical, and functional level. Considering the necessary changes to the MR scanner design the feasibility of arterial spin labeling (ASL) is unclear. To evaluate whether cerebral blood flow imaging with ASL is feasible using a prototype PET/MRI device. ASL imaging of the brain with Flow-sensitive Alternating Inversion Recovery (FAIR) spin preparation and true fast imaging in steady precession (TrueFISP) data readout was performed in eight healthy volunteers sequentially on a prototype PET/MRI and a stand-alone MR scanner with 128 × 128 and 192 × 192 matrix sizes. Cerebral blood flow values for gray matter, signal-to-noise and contrast-to-noise ratios, and relative signal change were compared. Additionally, the feasibility of ASL as part of a clinical hybrid PET/MRI protocol was demonstrated in five patients with intracerebral tumors. Blood flow maps showed good delineation of gray and white matter with no discernible artifacts. The mean blood flow values of the eight volunteers on the PET/MR system were 51 ± 9 and 51 ± 7 mL/100 g/min for the 128 × 128 and 192 × 192 matrices (stand-alone MR, 57 ± 2 and 55 ± 5, not significant). The value for signal-to-noise (SNR) was significantly higher for the PET/MRI system using the 192 × 192 matrix size (P change (δS) was significantly lower for the 192 × 192 matrix size (P = 0.02). ASL imaging as part of a clinical hybrid PET/MRI protocol could successfully be accomplished in all patients in diagnostic image quality. ASL brain imaging is feasible with a prototype hybrid PET/MRI scanner, thus adding to the value of this novel imaging technique.

  2. Functional MRI in children: clinical and research applications

    International Nuclear Information System (INIS)

    Leach, James L.; Holland, Scott K.

    2010-01-01

    Functional MRI has become a critical research tool for evaluating brain function and developmental trajectories in children. Its clinical use in children is becoming more common. This presentation will review the basic underlying physiologic and technical aspects of fMRI, review research applications that have direct clinical relevance, and outline the current clinical uses of this technology. (orig.)

  3. MRI in the assessment of congenital vaginal anomalies

    International Nuclear Information System (INIS)

    Humphries, P.D.; Simpson, J.C.; Creighton, S.M.; Hall-Craggs, M.A.

    2008-01-01

    Aim: To assess accuracy of magnetic resonance imaging (MRI) for the delineation of morphological abnormalities of the vagina in patients with congenital anomalies of the genito-urinary tract. Materials and methods: Fifty-one patients (median age 19 years; range 12-40 years) were studied. All were consecutively referred for MRI to assess genital tract anatomy, between 1996 and 2004, from a clinic specializing in congenital abnormalities of the urogenital tract. All patients were assessed clinically and underwent MRI. Images were reviewed retrospectively by an experienced radiologist. Where there was discordance between clinical and radiological findings a consensus diagnosis was achieved by the gynaecologists and radiologists reviewing all of the clinical and radiological evidence together, including assessment of vaginal length. Results: The clinical data were incomplete for five women and the images non-diagnostic in two cases; consequently, 44 of 51 women had complete datasets and could be evaluated. Vaginas were abnormal in 30 of the 44 patients. There was discordance between the clinical and imaging findings at the initial review in three of the 44 cases (6.8%). After consensus review, and with the inclusion of measurement of the vaginal length on MRI, the MRI and clinical findings were concordant in all cases. The initial discordance was due to two vaginal dimples not being appreciated on MRI and one case in which presence of vaginal tissue proximal to a mid-segment obstruction was not appreciated clinically. Conclusion: MRI is an accurate method of imaging vaginal anomalies. However, to achieve reliable results the radiologist requires details of previous surgery and the vaginal length must be measured

  4. MRI in the assessment of congenital vaginal anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Humphries, P.D. [Department of Radiology, University College Hospital, London (United Kingdom); Simpson, J.C.; Creighton, S.M. [Department of Obstetrics and Gynaecology, University College Hospital, London (United Kingdom); Hall-Craggs, M.A. [Department of Radiology, University College Hospital, London (United Kingdom)], E-mail: margaret.hall-craggs@uclh.nhs.uk

    2008-04-15

    Aim: To assess accuracy of magnetic resonance imaging (MRI) for the delineation of morphological abnormalities of the vagina in patients with congenital anomalies of the genito-urinary tract. Materials and methods: Fifty-one patients (median age 19 years; range 12-40 years) were studied. All were consecutively referred for MRI to assess genital tract anatomy, between 1996 and 2004, from a clinic specializing in congenital abnormalities of the urogenital tract. All patients were assessed clinically and underwent MRI. Images were reviewed retrospectively by an experienced radiologist. Where there was discordance between clinical and radiological findings a consensus diagnosis was achieved by the gynaecologists and radiologists reviewing all of the clinical and radiological evidence together, including assessment of vaginal length. Results: The clinical data were incomplete for five women and the images non-diagnostic in two cases; consequently, 44 of 51 women had complete datasets and could be evaluated. Vaginas were abnormal in 30 of the 44 patients. There was discordance between the clinical and imaging findings at the initial review in three of the 44 cases (6.8%). After consensus review, and with the inclusion of measurement of the vaginal length on MRI, the MRI and clinical findings were concordant in all cases. The initial discordance was due to two vaginal dimples not being appreciated on MRI and one case in which presence of vaginal tissue proximal to a mid-segment obstruction was not appreciated clinically. Conclusion: MRI is an accurate method of imaging vaginal anomalies. However, to achieve reliable results the radiologist requires details of previous surgery and the vaginal length must be measured.

  5. DIAGNOSTIC IMAGING IN A DIRECT-ACCESS SPORTS PHYSICAL THERAPY CLINIC: A 2-YEAR RETROSPECTIVE PRACTICE ANALYSIS.

    Science.gov (United States)

    Crowell, Michael S; Dedekam, Erik A; Johnson, Michael R; Dembowski, Scott C; Westrick, Richard B; Goss, Donald L

    2016-10-01

    While advanced diagnostic imaging is a large contributor to the growth in health care costs, direct-access to physical therapy is associated with decreased rates of diagnostic imaging. No study has systematically evaluated with evidence-based criteria the appropriateness of advanced diagnostic imaging, including magnetic resonance imaging (MRI), when ordered by physical therapists. The primary purpose of this study was to describe the appropriateness of magnetic resonance imaging (MRI) or magnetic resonance arthrogram (MRA) exams ordered by physical therapists in a direct-access sports physical therapy clinic. Retrospective observational study of practice. Greater than 80% of advanced diagnostic imaging orders would have an American College of Radiology (ACR) Appropriateness Criteria rating of greater than 6, indicating an imaging order that is usually appropriate. A 2-year retrospective analysis identified 108 MRI/MRA examination orders from four physical therapists. A board-certified radiologist determined the appropriateness of each order based on ACR appropriateness criteria. The principal investigator and co-investigator radiologist assessed agreement between the clinical diagnosis and MRI/surgical findings. Knee (31%) and shoulder (25%) injuries were the most common. Overall, 55% of injuries were acute. The mean ACR rating was 7.7; scores from six to nine have been considered appropriate orders and higher ratings are better. The percentage of orders complying with ACR appropriateness criteria was 83.2%. Physical therapist's clinical diagnosis was confirmed by MRI/MRA findings in 64.8% of cases and was confirmed by surgical findings in 90% of cases. Physical therapists providing musculoskeletal primary care in a direct-access sports physical therapy clinic appropriately ordered advanced diagnostic imaging in over 80% of cases. Future research should prospectively compare physical therapist appropriateness and utilization to other groups of providers and

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) procedure View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic ...

  7. Neuronal ceroid-lipofuscinosis in longhaired Chihuahuas: clinical, pathologic, and MRI findings.

    Science.gov (United States)

    Nakamoto, Yuya; Yamato, Osamu; Uchida, Kazuyuki; Nibe, Kazumi; Tamura, Shinji; Ozawa, Tsuyoshi; Ueoka, Naotami; Nukaya, Aya; Yabuki, Akira; Nakaichi, Munekazu

    2011-01-01

    Neuronal ceroid-lipofuscinosis (NCL) is a rare group of inherited neurodegenerative lysosomal storage diseases characterized histopathologically by the abnormal accumulation of ceroid- or lipofuscin-like lipopigments in neurons and other cells throughout the body. The present article describes the clinical, pathologic, and magnetic resonance imaging (MRI) findings of the NCL in three longhaired Chihuahuas between 16 mo and 24 mo of age. Clinical signs, including visual defects and behavioral abnormalities, started between 16 mo and 18 mo of age. Cranial MRI findings in all the dogs were characterized by diffuse severe dilation of the cerebral sulci, dilated fissures of diencephalons, midbrain, and cerebellum, and lateral ventricular enlargement, suggesting atrophy of the forebrain. As the most unusual feature, diffuse meningeal thickening was observed over the entire cerebrum, which was strongly enhanced on contrast T1-weighted images. The dogs' conditions progressed until they each died subsequent to continued neurologic deterioration between 23 mo and 24 mo of age. Histopathologically, there was severe to moderate neuronal cell loss with diffuse astrogliosis throughout the brain. The remaining neuronal cells showed intracytoplasmic accumulation of pale to slightly yellow lipopigments mimicking ceroid or lipofuscin. The thickened meninges consisted of the proliferation of connective tissues with abundant collagen fibers and mild infiltration of inflammatory cells suggesting neuroimmune hyperactivity. Although the etiology of this neuroimmune hyperactivity is not currently known, MRI findings such as meningeal thickening may be a useful diagnostic marker of this variant form of canine NCL.

  8. FDG whole-body PET/MRI in oncology: A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyun Woo [Dept. of Nuclear Medicine, Soonchunhyang University Hospital, Cheonan (Korea, Republic of); Becker, Ann-Katharina [Rheinisch Westfalische Technische Hochschule Aachen University, Aachen (Germany); Goo, Jin Mo; Cheon, Gi Jeong [Seoul National University, College of Medicine,Seoul (Korea, Republic of)

    2017-03-15

    The recent advance in hybrid imaging techniques enables offering simultaneous positron emission tomography (PET)/magnetic resonance imaging (MRI) in various clinical fields. 18F-fluorodeoxyglucose (FDG) PET has been widely used for diagnosis and evaluation of oncologic patients. The growing evidence from research and clinical experiences demonstrated that PET/MRI with FDG can provide comparable or superior diagnostic performance more than conventional radiological imaging such as computed tomography (CT), MRI or PET/CT in various cancers. Combined analysis using structural information and functional/molecular information of tumors can draw additional diagnostic information based on PET/MRI. Further studies including determination of the diagnostic efficacy, optimizing the examination protocol, and analysis of the hybrid imaging results is necessary for extending the FDG PET/MRI application in clinical oncology.

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive imaging test ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... and send a signed report to your primary care or referring physician, who will share the results ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the exam. MRI scanners are air-conditioned and well-lit. Music may be played through the headphones ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI can detect stroke at a very early stage by mapping the motion of water molecules in ... is because traction devices and many types of life support equipment may distort the MR images and ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam ... and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... and may add approximately 15 minutes to the total exam time. top of page What will I ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... it may cause some medical devices to malfunction. Most orthopedic implants pose no risk, but you should ... a digital cloud server. Currently, MRI is the most sensitive imaging test of the head (particularly the ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... tissue from which they come. The MR scanner captures this energy and creates a picture of the ... imaging based on the electrical activity of the heart, such as electrocardiography (EKG). MRI generally is not ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... used in tattoos may contain iron and could heat up during an MRI scan, but this is ... called MR angiography (MRA) provides detailed images of blood vessels in the brain—often without the need ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... others nearby harm. These items include: jewelry, watches, credit cards and hearing aids, all of which can ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... to produce detailed pictures of organs, soft tissues, bone and virtually all other internal body structures. MRI ... discovery of abnormalities that might be obscured by bone with other imaging methods. The contrast material used ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Examples include but are not limited to: artificial heart valves implanted drug infusion ports artificial limbs or ... imaging based on the electrical activity of the heart, such as electrocardiography (EKG). MRI generally is not ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... to a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive imaging ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... distort images of the facial area or brain, so you should let the radiologist know about them. ... MRI units, called short-bore systems , are designed so that the magnet does not completely surround you. ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... tissue and fluid, known as edema . MRI typically costs more and may take more time to perform ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI. For more information, consult your radiologist. The computer workstation that processes the imaging information is located ... not come in contact with the patient. A computer then processes the signals and generates a series ...

  7. The clinical value of routine whole-body magnetic resonance imaging (MRI) in palliative care

    Energy Technology Data Exchange (ETDEWEB)

    Geitung, Jonn Terje (Department of Radiology, Haraldspass Deaconess (University) Hospital (Norway); Department of Surgical Sciences, University of Bergen (Norway)), Email: jtgeit@online.no; Eikeland, Joakim (Department of Public Health and Primary Health Care, University of Bergen (Norway)); Rosland, Jan Henrik (Department of Public Health and Primary Health Care, University of Bergen (Norway); Sunniva Clinic for Palliative Care, Haraldsplass Deaconess (University) Hospital (Norway))

    2012-03-15

    Background. Whole-body MRI (WBMRI) has become an accessible method for detecting different types of pathologies both in the skeleton and the viscera, which may explain painful conditions, for example tumors and inflammation. Purpose. To assess a possible value of using WBMRI in order to improve palliative care. Material and Methods. Twenty patients (all eligible patients) admitted to the Department for Palliative Care were consecutively included in this study. They underwent a modified WBMRI, with fewer and shorter pulse sequences than in a standard WBMRI, to reduce patient stress. However, the patients' physicians were to exclude patients where little might be obtained and discomfort, distress, and pain could be induced. The treating physicians registered clinical utility directly after receiving the MRI report in a questionnaire. The registration was repeated after ended treatment. Results. Eighty percent had new findings detected, and 40% of the patients had a change in treatment due to the MRI result, mainly changes in analgesics and/or radiation therapy. Conclusion. The WBMRI helped the clinicians to improve treatment and a majority of the patients benefited from this. In eight patients the treatment was changed due to the results. The clinical value (utility) was indicated to be high

  8. Trends in magnetic resonance imaging. Technical trends in MRI, noise reduction and fast imaging

    International Nuclear Information System (INIS)

    Sugimoto, Hiroshi

    2007-01-01

    At MRI examination, patients suffer the machine noise and long tight lying as well as an oppressive feeling. This paper describes the technological efforts against the former two. The noise is generated from the force (thumb-ward) to vibrate the magnetic field gradient coil according to the left-hand rule. Authors have developed a MRI machine (Pianissimo) where the coil is placed in vacuum and its actual noise level is found reduced from 105 - 112 to 84 dB(A) at 1.5T. Fast imaging to shorten the imaging time is attained by combination of parallel imaging where MR signals are into multiple high frequency receiver coils, and the usual pulse sequence imaging, which results in the increased encoding in a given time. Together with these, MR angiography and diffusion weighted imaging of abdomen for cancer examination are becoming popular as an additional MRI diagnosis, also acceptable to patients. Future progress of MRI machines conceivably accompanies the unavoidable noise increase and possibly significant magnetic effects on human body, and efforts for their reduction will be continued at patients' viewpoint. (T.I.)

  9. Magnetic resonance imaging- physical principles and clinical application

    International Nuclear Information System (INIS)

    Tavri, Omprakash J.

    1996-01-01

    The advances in equipment and knowledge related to radiology are occurring at an astonishingly rapid rate. On November 8, 1895, William Conrad Roentgen discovered x-rays. In 1972, Godfrey Hounsfield and George Ambrose introduced computec tomography at a meeting of the British Institute of Radiology. In the same year, Paul Lauterbur published the idea of spatially resolving nuclear magnetic resonance samples, naming it zeugmatography. In 1977, Waldo Hinshaw and co-workers published a magnetic resonance image of a human hand and wrist, and by 1981 several centres were obtaining clinical magnetic resonance (MR) images. In a very short time, magnetic resonance imaging (MRI) has gained acceptance as a clinically useful imaging tool. (author)

  10. Supervised methods for detection and segmentation of tissues in clinical lumbar MRI.

    Science.gov (United States)

    Ghosh, Subarna; Chaudhary, Vipin

    2014-10-01

    Lower back pain (LBP) is widely prevalent all over the world and more than 80% of the people suffer from LBP at some point of their lives. Moreover, a shortage of radiologists is the most pressing cause for the need of CAD (computer-aided diagnosis) systems. Automatic localization and labeling of intervertebral discs from lumbar MRI is the first step towards computer-aided diagnosis of lower back ailments. Subsequently, for diagnosis and characterization (quantification and localization) of abnormalities like disc herniation and stenosis, a completely automatic segmentation of intervertebral discs and the dural sac is extremely important. Contribution of this paper towards clinical CAD systems is two-fold. First, we propose a method to automatically detect all visible intervertebral discs in clinical sagittal MRI using heuristics and machine learning techniques. We provide a novel end-to-end framework that outputs a tight bounding box for each disc, instead of simply marking the centroid of discs, as has been the trend in the recent past. Second, we propose a method to simultaneously segment all the tissues (vertebrae, intervertebral disc, dural sac and background) in a lumbar sagittal MRI, using an auto-context approach instead of any explicit shape features or models. Past work tackles the lumbar segmentation problem on a tissue/organ basis, and which tend to perform poorly in clinical scans due to high variability in appearance. We, on the other hand, train a series of robust classifiers (random forests) using image features and sparsely sampled context features, which implicitly represent the shape and configuration of the image. Both these methods have been tested on a huge clinical dataset comprising of 212 cases and show very promising results for both disc detection (98% disc localization accuracy and 2.08mm mean deviation) and sagittal MRI segmentation (dice similarity indices of 0.87 and 0.84 for the dural sac and the inter-vertebral disc, respectively

  11. Relationship between MRI and clinical findings in the acromioclavicular joint

    International Nuclear Information System (INIS)

    Jordan, L.K.; Griffiths, H.L.; Kenter, K.

    2002-01-01

    Objective: To determine the relationship between the magnetic resonance (MR) appearance of the acromioclavicular (AC) joint and the physical findings. Design: A total of 116 consecutive patients underwent routine MR imaging (MRI) of the shoulder over an 18-month period. All MR studies were interpreted by a blinded, experienced musculoskeletal radiologist. Eleven variables were studied: the presence of osteophytes; fluid in the joint; fluid outside the joint; high signal in the clavicle or in the acromion; fluid in the subacromial bursa; irregularity of the joint margins; bulging of the capsule; widening of the joint; the age of the patient; and the presence of a rotator cuff tear. The clinical information was supplied by an experienced shoulder surgeon blinded to the MRI findings. A control group of 23 normal volunteers was also studied. Results: The only statistically significant correlation (P=0.0249) was between high signal in the distal clavicle and degenerative changes found clinically. A weaker relationship existed between fluid in the joint and the clinical examination and between increasing degenerative changes and advancing age. Otherwise, no material relationship was found between any of the other MR abnormalities and the clinical picture. Conclusion: There appears to be no real correlation between the MR appearances and the clinical findings in the AC joint. (orig.)

  12. Relationship between MRI and clinical findings in the acromioclavicular joint

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, L.K.; Griffiths, H.L. [Department of Radiology, University of Missouri Health Care (United States); Kenter, K. [Department of Orthopedics, University of Missouri Health Care (United States)

    2002-09-01

    Objective: To determine the relationship between the magnetic resonance (MR) appearance of the acromioclavicular (AC) joint and the physical findings. Design: A total of 116 consecutive patients underwent routine MR imaging (MRI) of the shoulder over an 18-month period. All MR studies were interpreted by a blinded, experienced musculoskeletal radiologist. Eleven variables were studied: the presence of osteophytes; fluid in the joint; fluid outside the joint; high signal in the clavicle or in the acromion; fluid in the subacromial bursa; irregularity of the joint margins; bulging of the capsule; widening of the joint; the age of the patient; and the presence of a rotator cuff tear. The clinical information was supplied by an experienced shoulder surgeon blinded to the MRI findings. A control group of 23 normal volunteers was also studied. Results: The only statistically significant correlation (P=0.0249) was between high signal in the distal clavicle and degenerative changes found clinically. A weaker relationship existed between fluid in the joint and the clinical examination and between increasing degenerative changes and advancing age. Otherwise, no material relationship was found between any of the other MR abnormalities and the clinical picture. Conclusion: There appears to be no real correlation between the MR appearances and the clinical findings in the AC joint. (orig.)

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... an MRI scan, but this is rare. Tooth fillings and braces usually are not affected by the magnetic field, but they may distort images of the facial area or brain, so you should let the ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association ... MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org : Radiation Therapy for Brain Tumors Radiation Therapy for ... Imaging (MRI) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  16. Evaluation of carcinoma cervix using magnetic resonance imaging: correlation with clinical FIGO staging and impact on management

    International Nuclear Information System (INIS)

    Dhoot, Nilu Malpani; Bhuyan, Utpal; Kumar, Vinay; Shinagare, Atul; Kataki, Amal Chandra; Barmon, Debabrata

    2012-01-01

    To evaluate carcinoma of the cervix using magnetic resonance imaging (MRI), correlate with clinical approach of International Federation of Gynecology and Obstetrics (FIGO) staging system and to study the impact of MRI findings on patient management. Pathologically confirmed, 75 cases of carcinoma cervix referred to our institute from April 2007 to March 2008 were prospectively studied. Clinical FIGO stage was assigned to each patient by gynaecologists blinded to MRI findings. MRI stage (based on FIGO and TNM) was allotted by radiologists blinded to clinicopathological details. For patients who were operated, histopathological stage was taken as gold standard. For patients who were not operated, gynaecologists decided on a gold standard stage based on all available clinical and imaging data. MR staging was correlated with FIGO staging, with focus on significant alterations in treatment strategy caused due to MRI findings. MRI staging had an accuracy of 89.3% (67/75), while clinical FIGO staging had 61.3% (46/75) accuracy. MRI staging and FIGO staging concurred in 65.6% of the patients and differed in 34.4% of the patients. In about 30.6% (23/75) of the patients, there were relevant additional MRI findings not suspected clinically. The common significant MRI findings were detection of pelvic lymphadenopathy and clinically unsuspected bowel/bladder invasion. The management protocol was significantly altered in 86.9% (20/23) of the patients with additional MRI findings constituting 26.6% (20/75) of the total population. MRI is highly accurate in evaluating carcinoma of the cervix. MRI findings significantly altered therapeutic decisions in 26.6% of the patients. MRI should be considered prior to treatment planning in every patient.

  17. Diagnostic yield of MRI for audiovestibular dysfunction using contemporary referral criteria: correlation with presenting symptoms and impact on clinical management

    Energy Technology Data Exchange (ETDEWEB)

    Vandervelde, C. [Department of Radiology, Guy' s and St Thomas' NHS Foundation Trust (United Kingdom)], E-mail: clivevandervelde@gmail.com; Connor, S E.J. [Department of Radiology, Guy' s and St Thomas' NHS Foundation Trust (United Kingdom); Department of Neuroradiology, King' s College Hospital NHS Foundation Trust, London (United Kingdom)

    2009-02-15

    Aim: To investigate the diagnostic yield of T2-weighted magnetic resonance imaging (MRI) screening for vestibular schwannoma and other relevant conditions in the setting of audiovestibular symptoms, given the more liberal contemporary referral criteria. To determine whether presenting clinical symptoms correlate with imaging outcome in order to guide future protocols for MRI referral. Materials and methods: Eight hundred and eighty-one consecutive MRI examinations performed in patients with audiovestibular dysfunction were reviewed. Clinical indications and findings were recorded. Case notes were reviewed in patients with positive imaging findings. Two-way, cross-tabulation, Chi-square analysis was performed to assess the relationship between presenting symptoms and imaging outcome. Results: Twelve of the 881 (1.4%) were positive for vestibular schwannoma. A further four of 881 (0.4%) revealed other relevant conditions. Incidental conditions, felt to be irrelevant to the presenting symptoms, were noted in 12 of the 881 (1.4%). In all 12 cases that were positive for vestibular schwannoma, either tinnitus or hearing loss was present. Conclusion: The yield for T2-weighted MRI to diagnose vestibular schwannoma and other relevant retrocochlear conditions was lower than for previous studies, which is likely to reflect trends in referral criteria. No single audiovestibular symptom or combination of symptoms is a statistically significant predictor of imaging outcome.

  18. Diagnostic yield of MRI for audiovestibular dysfunction using contemporary referral criteria: correlation with presenting symptoms and impact on clinical management

    International Nuclear Information System (INIS)

    Vandervelde, C.; Connor, S.E.J.

    2009-01-01

    Aim: To investigate the diagnostic yield of T2-weighted magnetic resonance imaging (MRI) screening for vestibular schwannoma and other relevant conditions in the setting of audiovestibular symptoms, given the more liberal contemporary referral criteria. To determine whether presenting clinical symptoms correlate with imaging outcome in order to guide future protocols for MRI referral. Materials and methods: Eight hundred and eighty-one consecutive MRI examinations performed in patients with audiovestibular dysfunction were reviewed. Clinical indications and findings were recorded. Case notes were reviewed in patients with positive imaging findings. Two-way, cross-tabulation, Chi-square analysis was performed to assess the relationship between presenting symptoms and imaging outcome. Results: Twelve of the 881 (1.4%) were positive for vestibular schwannoma. A further four of 881 (0.4%) revealed other relevant conditions. Incidental conditions, felt to be irrelevant to the presenting symptoms, were noted in 12 of the 881 (1.4%). In all 12 cases that were positive for vestibular schwannoma, either tinnitus or hearing loss was present. Conclusion: The yield for T2-weighted MRI to diagnose vestibular schwannoma and other relevant retrocochlear conditions was lower than for previous studies, which is likely to reflect trends in referral criteria. No single audiovestibular symptom or combination of symptoms is a statistically significant predictor of imaging outcome

  19. Delayed-enhancement MRI of apical hypertrophic cardiomyopathy: assessment of the intramural distribution and comparison with clinical symptoms, ventricular arrhythmias, and cine MRI

    International Nuclear Information System (INIS)

    Amano, Yasuo; Fukushima, Yoshimitsu; Kumita, Shinichiro; Takayama, Morimasa; Kitamura, Mitsunobu

    2011-01-01

    Background: Hypertrophic cardiomyopathy (HCM) is reported to show patchy midwall myocardial hyper enhancement on delayed-enhancement magnetic resonance imaging (DE-MRI). The intramural distribution of myocardial hyper enhancement and its correlation with clinical symptoms, ventricular arrhythmias, and cardiac function have not been described for symptomatic apical HCM. Purpose: To evaluate the features and significance of myocardial hyper enhancement on DE-MRI in symptomatic apical HCM. Material and Methods: Thirteen patients with symptomatic apical HCM and their 65 apical segments were investigated. Myocardial hyper enhancement and regional and global functional parameters were determined with MRI. We investigated the intramural distribution and frequencies of this myocardial hyper enhancement and compared them with the patients' clinical symptoms, the presence of ventricular arrhythmias, and cine MRI. Results: Eight (61.5%) patients with symptomatic apical HCM displayed apical myocardial hyper enhancement, and 22 (33.8%) of the 65 apical segments examined showed myocardial hyper enhancement. Of the myocardial hyper enhancement observed, 81.8% showed a subendocardial pattern.The Hyperenhanced apical myocardium had a lower percentage of systolic myocardial thickening, and was associated with serious symptoms (e.g. syncope) and ventricular arrhythmias. Conclusion: Patients with symptomatic apical HCM showed myocardial hyper enhancement involving the subendocardial layer, which might be related to regional systolic dysfunction, serious clinical symptoms, and ventricular arrhythmias

  20. MRI of persistent cloaca: Can it substitute conventional imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Mohammad, Shaimaa Abdelsattar, E-mail: shaimaa96@hotmail.com [Department of Radiodiagnosis, Faculty of Medicine, Ain-Shams University (Egypt); AbouZeid, Amr Abdelhamid, E-mail: amrabdelhamid@hotmail.com [Department of Pediatric Surgery, Faculty of Medicine, Ain-Shams University (Egypt)

    2013-02-15

    Purpose: To define the role of MRI in the preoperative assessment of patients with persistent cloaca and whether it can substitute other imaging modalities. Methods: We prospectively examined eleven patients with persistent cloaca between July 2007 and March 2012. Non contrast MRI examinations were performed on 1.5 T magnet using head coil. Multiple pulse sequences (T1WI, T2WI, fat suppression) were obtained in axial, sagittal and coronal planes of the pelvis, abdomen, and spine. The scans were reviewed for the following: the level and type of rectal termination, the developmental state of striated muscle complex (SMC), associated genitourinary and spinal anomalies. MRI findings were compared to conventional fluoroscopic imaging, operative and endoscopic findings. We applied novel MRI parameters (urethral length, relative hiatal distance and vaginal volume). The relation between different parameters was tested statistically using Pearson correlation test. Results: MRI could accurately demonstrate the level of bowel termination in patients with persistent cloaca, in addition to its high sensitivity for detection of mullerian anomalies which were present in 73% of patients. Furthermore, MRI could disclose associating renal and spinal anomalies, and assess the developmental state of SMC. The shorter the urethra (higher urogenital confluence), the narrower the pelvic hiatus, and the more was the obstruction (vaginal distension). Conclusion: MRI is a valuable tool in exploring the different internal anatomical features of the cloacal anomaly; and when combined with endoscopy, MRI can make other preoperative conventional imaging unnecessary.

  1. MRI and CT Imaging of an Intrasphenoidal Encephalocele: A Case Report

    International Nuclear Information System (INIS)

    Agladioglu, Kadir; Ardic, Fazıl Necdet; Tumkaya, Funda; Bir, Ferda

    2014-01-01

    Intrasphenoidal encephalocele (ISE) is a rare clinical entity. The incidence of congenital encephalocele is very low. Accurate diagnosis and surgical approach is of critical value. We present a case of intrasphenoidal encephalocele in a 40-year-old man. He complained of cerebrospinal fluid (CSF) rhinorrhea and recurrent meningitis. In images of computed tomography (CT) and magnetic resonance imaging (MRI), intrasphenoidal encephalocele herniating through a defect of the left lateral sphenoid sinus wall was determined. Incisional biopsies were taken by endoscopic transnasal approach and histopathological examination revealed an encephalocele. In the differential diagnosis, ISE can be taken for inflammatory or malignant sinusoidal soft tissue masses. ISE is differentiated from other entities by demonstrating continuity with normal brain tissue. MRI clearly demonstrates that the herniating soft tissue is isointense with brain and continuous with brain tissue via the sphenoid sinus, thereby the treatment decision-making process is very important

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... On very rare occasions, a few patients experience side effects from the contrast material, including nausea, headache and ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians to evaluate various ... kind, such as an allergy to iodine or x-ray contrast material, drugs, food, or the environment, or ...

  4. Free Radical Imaging Using In Vivo Dynamic Nuclear Polarization-MRI.

    Science.gov (United States)

    Utsumi, Hideo; Hyodo, Fuminori

    2015-01-01

    Redox reactions that generate free radical intermediates are essential to metabolic processes, and their intermediates can produce reactive oxygen species, which may promote diseases related to oxidative stress. The development of an in vivo electron spin resonance (ESR) spectrometer and its imaging enables us noninvasive and direct measurement of in vivo free radical reactions in living organisms. The dynamic nuclear polarization magnetic resonance imaging (DNP-MRI), also called PEDRI or OMRI, is also a new imaging method for observing free radical species in vivo. The spatiotemporal resolution of free radical imaging with DNP-MRI is comparable with that in MRI, and each of the radical species can be distinguished in the spectroscopic images by changing the frequency or magnetic field of ESR irradiation. Several kinds of stable nitroxyl radicals were used as spin probes to detect in vivo redox reactions. The signal decay of nitroxyl probes, which is determined with in vivo DNP-MRI, reflects the redox status under oxidative stress, and the signal decay is suppressed by prior administration of antioxidants. In addition, DNP-MRI can also visualize various intermediate free radicals from the intrinsic redox molecules. This noninvasive method, in vivo DNP-MRI, could become a useful tool for investigating the mechanism of oxidative injuries in animal disease models and the in vivo effects of antioxidant drugs. © 2015 Elsevier Inc. All rights reserved.

  5. WE-DE-206-02: MRI Hardware - Magnet, Gradient, RF Coils

    Energy Technology Data Exchange (ETDEWEB)

    Kocharian, A. [Methodist Hospital (United States)

    2016-06-15

    Magnetic resonance imaging (MRI) has become an essential part of clinical imaging due to its ability to render high soft tissue contrast. Instead of ionizing radiation, MRI use strong magnetic field, radio frequency waves and field gradients to create diagnostic useful images. It can be used to image the anatomy and also functional and physiological activities within the human body. Knowledge of the basic physical principles underlying MRI acquisition is vitally important to successful image production and proper image interpretation. This lecture will give an overview of the spin physics, imaging principle of MRI, the hardware of the MRI scanner, and various pulse sequences and their applications. It aims to provide a conceptual foundation to understand the image formation process of a clinical MRI scanner. Learning Objectives: Understand the origin of the MR signal and contrast from the spin physics level. Understand the main hardware components of a MRI scanner and their purposes Understand steps for MR image formation including spatial encoding and image reconstruction Understand the main kinds of MR pulse sequences and their characteristics.

  6. Clinical findings just after return to play predict hamstring re-injury, but baseline MRI findings do not

    NARCIS (Netherlands)

    R.J. de Vos (Robert-Jan); G. Reurink (Gustaaf); G.J. Goudswaard (Gert Jan); M.H. Moen (Maaike); A. Weir (Adam); J.L. Tol (Johannes)

    2014-01-01

    markdownabstract__Abstract__ Background Acute hamstring re-injuries are common and hard to predict. The aim of this study was to investigate the association between clinical and imaging findings and the occurrence of hamstring re-injuries. Methods We obtained baseline data (clinical and MRI

  7. Hybrid cardiac imaging using PET/MRI: a joint position statement by the European Society of Cardiovascular Radiology (ESCR) and the European Association of Nuclear Medicine (EANM).

    Science.gov (United States)

    Nensa, Felix; Bamberg, Fabian; Rischpler, Christoph; Menezes, Leon; Poeppel, Thorsten D; la Fougère, Christian; Beitzke, Dietrich; Rasul, Sazan; Loewe, Christian; Nikolaou, Konstantin; Bucerius, Jan; Kjaer, Andreas; Gutberlet, Matthias; Prakken, Niek H; Vliegenthart, Rozemarijn; Slart, Riemer H J A; Nekolla, Stephan G; Lassen, Martin L; Pichler, Bernd J; Schlosser, Thomas; Jacquier, Alexis; Quick, Harald H; Schäfers, Michael; Hacker, Marcus

    2018-05-02

    Positron emission tomography (PET) and magnetic resonance imaging (MRI) have both been used for decades in cardiovascular imaging. Since 2010, hybrid PET/MRI using sequential and integrated scanner platforms has been available, with hybrid cardiac PET/MR imaging protocols increasingly incorporated into clinical workflows. Given the range of complementary information provided by each method, the use of hybrid PET/MRI may be justified and beneficial in particular clinical settings for the evaluation of different disease entities. In the present joint position statement, we critically review the role and value of integrated PET/MRI in cardiovascular imaging, provide a technical overview of cardiac PET/MRI and practical advice related to the cardiac PET/MRI workflow, identify cardiovascular applications that can potentially benefit from hybrid PET/MRI, and describe the needs for future development and research. In order to encourage its wide dissemination, this article is freely accessible on the European Radiology and European Journal of Hybrid Imaging web sites. • Studies and case-reports indicate that PET/MRI is a feasible and robust technology. • Promising fields of application include a variety of cardiac conditions. • Larger studies are required to demonstrate its incremental and cost-effective value. • The translation of novel radiopharmaceuticals and MR-sequences will provide exciting new opportunities.

  8. MR imaging assessment of clinical problems in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Narvaez, Jose A.; Roca, Yolanda; Aguilera, Carlos; Narvaez, Javier

    2002-01-01

    Although MR imaging has been increasingly recognized as a useful tool in the diagnosis of early rheumatoid arthritis (RA) and in the assessment of disease activity, these applications have not yet been usually included in the routine management of this condition. Our goal is to review the current role of MRI in the everyday clinical management of patients with RA. The usefulness of MRI in the evaluation of articular and para-articular changes in specific locations, mainly the craniocervical region and the temporomandibular joint, are reviewed. Clinical problems derived from local extra-articular involvement, such as tenosynovitis, ''rice-bodies'' bursitis, and Baker's cyst rupture, are also described. Finally, we also review the value of MRI in evaluation of some complications of RA such as tendinous rupture, osteonecrosis, stress fracture, and septic arthritis/osteomyelitis. (orig.)

  9. Reducing task-based fMRI scanning time using simultaneous multislice echo planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kiss, Mate [Hungarian Academy of Sciences, Brain Imaging Centre, Research Centre for Natural Sciences, Budapest (Hungary); Janos Szentagothai PhD School, MR Research Centre, Budapest (Hungary); National Institute of Clinical Neuroscience, Department of Neuroradiology, Budapest (Hungary); Hermann, Petra; Vidnyanszky, Zoltan; Gal, Viktor [Hungarian Academy of Sciences, Brain Imaging Centre, Research Centre for Natural Sciences, Budapest (Hungary)

    2018-03-15

    To maintain alertness and to remain motionless during scanning represent a substantial challenge for patients/subjects involved in both clinical and research functional magnetic resonance imaging (fMRI) examinations. Therefore, availability and application of new data acquisition protocols allowing the shortening of scan time without compromising the data quality and statistical power are of major importance. Higher order category-selective visual cortical areas were identified individually, and rapid event-related fMRI design was used to compare three different sampling rates (TR = 2000, 1000, and 410 ms, using state-of-the-art simultaneous multislice imaging) and four different scanning lengths to match the statistical power of the traditional scanning methods to high sampling-rate design. The results revealed that ∝ 4 min of the scan time with 1 Hz (TR = 1000 ms) sampling rate and ∝ 2 min scanning at ∝ 2.5 Hz (TR = 410 ms) sampling rate provide similar localization sensitivity and selectivity to that obtained with 11-min session at conventional, 0.5 Hz (TR = 2000 ms) sampling rate. Our findings suggest that task-based fMRI examination of clinical population prone to distress such as presurgical mapping experiments might substantially benefit from the reduced (20-40%) scanning time that can be achieved by the application of simultaneous multislice sequences. (orig.)

  10. Real-time functional MR imaging (fMRI) for presurgical evaluation of paediatric epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Kesavadas, Chandrasekharan; Thomas, Bejoy; Kumar Gupta, Arun [Sree Chitra Tirunal Institute for Medical Sciences and Technology, Department of Imaging Sciences and Interventional Radiology, Trivandrum (India); Sujesh, Sreedharan [Sree Chitra Tirunal Institute for Medical Sciences and Technology, Biomedical Technology Wing, Trivandrum (India); Ashalata, Radhakrishnan; Radhakrishnan, Kurupath [Sree Chitra Tirunal Institute for Medical Sciences and Technology, Department of Neurology, Trivandrum (India); Abraham, Mathew [Sree Chitra Tirunal Institute for Medical Sciences and Technology, Department of Neurosurgery, Trivandrum (India)

    2007-10-15

    The role of fMRI in the presurgical evaluation of children with intractable epilepsy is being increasingly recognized. Real-time fMRI allows the clinician to visualize functional brain activation in real time. Since there is no off-line data analysis as in conventional fMRI, the overall time for the procedure is reduced, making it clinically feasible in a busy clinical sitting. (1) To study the accuracy of real-time fMRI in comparison to conventional fMRI with off-line processing; (2) to determine its effectiveness in mapping the eloquent cortex and language lateralization in comparison to invasive procedures such as intraoperative cortical stimulation and Wada testing; and (3) to evaluate the role of fMRI in presurgical decision making in children with epilepsy. A total of 23 patients (age range 6-18 years) underwent fMRI with sensorimotor, visual and language paradigms. Data processing was done in real time using in-line BOLD. The results of real-time fMRI matched those of off-line processing done using the well-accepted standard technique of statistical parametric mapping (SPM) in all the initial ten patients in whom the two techniques were compared. Coregistration of the fMRI data on a 3-D FLAIR sequence rather than a T1-weighted image gave better information regarding the relationship of the lesion to the area of activation. The results of intraoperative cortical stimulation and fMRI matched in six out of six patients, while the Wada test and fMRI had similar results in four out of five patients in whom these techniques were performed. In the majority of patients in this series the technique influenced patient management. Real-time fMRI is an easily performed and reliable technique in the presurgical workup of children with epilepsy. (orig.)

  11. Real-time functional MR imaging (fMRI) for presurgical evaluation of paediatric epilepsy

    International Nuclear Information System (INIS)

    Kesavadas, Chandrasekharan; Thomas, Bejoy; Kumar Gupta, Arun; Sujesh, Sreedharan; Ashalata, Radhakrishnan; Radhakrishnan, Kurupath; Abraham, Mathew

    2007-01-01

    The role of fMRI in the presurgical evaluation of children with intractable epilepsy is being increasingly recognized. Real-time fMRI allows the clinician to visualize functional brain activation in real time. Since there is no off-line data analysis as in conventional fMRI, the overall time for the procedure is reduced, making it clinically feasible in a busy clinical sitting. (1) To study the accuracy of real-time fMRI in comparison to conventional fMRI with off-line processing; (2) to determine its effectiveness in mapping the eloquent cortex and language lateralization in comparison to invasive procedures such as intraoperative cortical stimulation and Wada testing; and (3) to evaluate the role of fMRI in presurgical decision making in children with epilepsy. A total of 23 patients (age range 6-18 years) underwent fMRI with sensorimotor, visual and language paradigms. Data processing was done in real time using in-line BOLD. The results of real-time fMRI matched those of off-line processing done using the well-accepted standard technique of statistical parametric mapping (SPM) in all the initial ten patients in whom the two techniques were compared. Coregistration of the fMRI data on a 3-D FLAIR sequence rather than a T1-weighted image gave better information regarding the relationship of the lesion to the area of activation. The results of intraoperative cortical stimulation and fMRI matched in six out of six patients, while the Wada test and fMRI had similar results in four out of five patients in whom these techniques were performed. In the majority of patients in this series the technique influenced patient management. Real-time fMRI is an easily performed and reliable technique in the presurgical workup of children with epilepsy. (orig.)

  12. Abnormal findings of magnetic resonance imaging (MRI) in patients with systemic lupus erythematosus involving the brain

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Akira; Okada, Jun; Kondo, Hirobumi (Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine); Kashiwazaki, Sadao

    1992-06-01

    To elucidate the clinical significance of MRI on central nervous system systemic lupus erythematosus (CNS-SLE), MRI and CT scans were performed in 35 patients with SLE, of 18 patients who had CNS manifestations at the time of MRI examinations. The investigations were also carried out in 17 patients without CNS-SLE. The rate of detection of abnormal findings on MRI in patients with CNS-SLE was 77.2% (14/18), which was high, as compared with the rate of those on CT scans (50%: 9/18). Especially, all of 4 patients with seizure and 3 patients with encephalopathy showed abnormal MRI findings, although respectively 50% and 33.3% of them had abnormal CT scan findings. MRI findings were classified into 4 groups below: (1) Large focal are as increased signal intensity at T2 weighted image. These were observed in 2 of 4 patients with seizure and 1 of 3 patients with encephalopathy, which were completely resolved after treatment. (2) Patchy subcortical foci of increased signal intensity at T2 weighted image. These were observed in 11 of 18 CNS-SLE and 7 of 17 without CNS-SLE, which were not detected by CT scan. (3) All of six patients with cerebral infarctions showed high signal intensity areas at T2 weighted image and low signal intensity areas at T1 weighted image. (4) Normal findings were observed in 4 of 18 CNS-SLE (22.2%). We concluded that MRI is useful for the evaluation of CNS-SLE and provides more information than CT scan. (author).

  13. Abnormal findings of magnetic resonance imaging (MRI) in patients with systemic lupus erythematosus involving the brain

    International Nuclear Information System (INIS)

    Ishikawa, Akira; Okada, Jun; Kondo, Hirobumi; Kashiwazaki, Sadao.

    1992-01-01

    To elucidate the clinical significance of MRI on central nervous system systemic lupus erythematosus (CNS-SLE), MRI and CT scans were performed in 35 patients with SLE, of 18 patients who had CNS manifestations at the time of MRI examinations. The investigations were also carried out in 17 patients without CNS-SLE. The rate of detection of abnormal findings on MRI in patients with CNS-SLE was 77.2% (14/18), which was high, as compared with the rate of those on CT scans (50%: 9/18). Especially, all of 4 patients with seizure and 3 patients with encephalopathy showed abnormal MRI findings, although respectively 50% and 33.3% of them had abnormal CT scan findings. MRI findings were classified into 4 groups below: 1) Large focal are as increased signal intensity at T2 weighted image. These were observed in 2 of 4 patients with seizure and 1 of 3 patients with encephalopathy, which were completely resolved after treatment. 2) Patchy subcortical foci of increased signal intensity at T2 weighted image. These were observed in 11 of 18 CNS-SLE and 7 of 17 without CNS-SLE, which were not detected by CT scan. 3) All of six patients with cerebral infarctions showed high signal intensity areas at T2 weighted image and low signal intensity areas at T1 weighted image. 4) Normal findings were observed in 4 of 18 CNS-SLE (22.2%). We concluded that MRI is useful for the evaluation of CNS-SLE and provides more information than CT scan. (author)

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... internal body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians to evaluate various ... kind, such as an allergy to iodine or x-ray contrast material, drugs, food, or the environment, or ...

  15. Review of MRI technique and imaging findings in athletic pubalgia and the "sports hernia".

    Science.gov (United States)

    Mullens, Frank E; Zoga, Adam C; Morrison, William B; Meyers, William C

    2012-12-01

    The clinical syndrome of athletic pubalgia has prematurely ended many promising athletic careers, has made many active, fitness conscious adults more sedentary, and has served as a diagnostic and therapeutic conundrum for innumerable trainers and physicians worldwide for decades. This diagnosis actually arises from one or more lesions within a spectrum of musculoskeletal and visceral injuries. In recent years, MRI has helped define many of these syndromes, and has proven to be both sensitive and specific for numerous potential causes of athletic pubalgia. This text will provide a comprehensive, up to date review of expected and sometimes unexpected MRI findings in the setting of athletic pubalgia, and will delineate an imaging algorithm and MRI protocol to help guide radiologists and other clinicians dealing with refractory, activity related groin pain in an otherwise young, healthy patient. There is still more to be learned about prevention and treatment plans for athletic pubalgia lesions, but accurate diagnosis should be much less nebulous and difficult with the use of MRI as a primary imaging modality. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  16. Experimental and clinical evaluation of acromioclavicular joint structures with new scan orientations in MRI

    International Nuclear Information System (INIS)

    Schaefer, Fritz K.; Schaefer, Philipp J.; Brossmann, Joachim; Hilgert, Ralf Erik; Heller, Martin; Jahnke, Thomas

    2006-01-01

    The objective of the study was to evaluate MRI for visualization of acromioclavicular (ac) joint structures in cadaveric shoulders, asymptomatic volunteers and symptomatic patients with trauma of the ac-joint. Three cadaveric shoulders were examined to find adequate planes and sequences for MRI. Afterwards, MR images were correlated to corresponding anatomical sections. Six asymptomatic volunteers and 13 patients were scanned in a 1.5 T Magnetom Vision with three sequences in the following planes: (1) parallel to the clavicle; (2) orthogonal to the ac joint, each time a fat-suppressed proton density-weighted + T2-sequence (TR/TE 4,000/15 ms) was performed; (3) parallel to the clavicle, T1-SE (TR/TE 817/20 ms). The parameters were: slice thickness 3 mm, field-of-view 180 mm, matrix 210 x 256 pixels. Standard of reference in the patients was clinical examination and conventional X-rays. Classification was by Rockwood grades I-VI. MRI allowed excellent visualization and diagnoses of ac-joint structures in volunteers and patients (n=6 normal, n=1 Rockwood I, n=5 Rockwood II, n=3 Rockwood III, n=4 Rockwood V). On MRI, in one lesion type II and III each, a lower lesion type was suspected clinically and by X-ray. In one patient additional information by MRI led to surgery. MRI allows excellent anatomical display of ac-joint structures and can give clinically relevant information on type and extension of ac-joint trauma, which may influence therapy. (orig.)

  17. Experimental and clinical evaluation of acromioclavicular joint structures with new scan orientations in MRI

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Fritz K.; Schaefer, Philipp J.; Brossmann, Joachim; Hilgert, Ralf Erik; Heller, Martin; Jahnke, Thomas [University Hospital of Schleswig-Holstein Campus Kiel, Department of Diagnostic Radiology, Kiel (Germany)

    2006-07-15

    The objective of the study was to evaluate MRI for visualization of acromioclavicular (ac) joint structures in cadaveric shoulders, asymptomatic volunteers and symptomatic patients with trauma of the ac-joint. Three cadaveric shoulders were examined to find adequate planes and sequences for MRI. Afterwards, MR images were correlated to corresponding anatomical sections. Six asymptomatic volunteers and 13 patients were scanned in a 1.5 T Magnetom Vision with three sequences in the following planes: (1) parallel to the clavicle; (2) orthogonal to the ac joint, each time a fat-suppressed proton density-weighted + T2-sequence (TR/TE 4,000/15 ms) was performed; (3) parallel to the clavicle, T1-SE (TR/TE 817/20 ms). The parameters were: slice thickness 3 mm, field-of-view 180 mm, matrix 210 x 256 pixels. Standard of reference in the patients was clinical examination and conventional X-rays. Classification was by Rockwood grades I-VI. MRI allowed excellent visualization and diagnoses of ac-joint structures in volunteers and patients (n=6 normal, n=1 Rockwood I, n=5 Rockwood II, n=3 Rockwood III, n=4 Rockwood V). On MRI, in one lesion type II and III each, a lower lesion type was suspected clinically and by X-ray. In one patient additional information by MRI led to surgery. MRI allows excellent anatomical display of ac-joint structures and can give clinically relevant information on type and extension of ac-joint trauma, which may influence therapy. (orig.)

  18. Late whiplash syndrome: a clinical and magnetic resonance imaging study.

    Science.gov (United States)

    Bonuccelli, U; Pavese, N; Lucetti, C; Renna, M R; Gambaccini, G; Bernardini, S; Canapicchi, R; Carrozzi, L; Murri, L

    1999-01-01

    Cervical hyperextension injuries are common and are associated with significant morbidity. Clinically two syndromes are described: "acute" whiplash syndrome and "late" whiplash syndrome (in which the patients are still symptomatic after six months despite normal physical and radiological examination). In order to clarify the pathology of the persistent pain in late whiplash syndrome we performed a cervical spine magnetic resonance imaging (MRI) in 33 consecutive patients suffering from this condition. Twenty-six patients (78.8%) showed MRI abnormalities, the most common MRI finding (57.6%) was pre-existent spondylosis. Indeed, the group of patients with spondylosis and other MRI changes had higher clinical scores than those without MRI abnormalities as measured by a three-point grading system based upon the symptoms and signs shown. Several MRI changes, most of them already demonstrable by standard X-ray were seen among 33 patients suffering from late whiplash syndrome. Although no one of these findings appears to be specific and certainly related to the previous neck injury, they could represent a risk factor for a longer pain duration.

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... very early stage by mapping the motion of water molecules in the tissue. This water motion, known as diffusion, is impaired by most ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  20. Developments in boron magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Schweizer, M.

    1995-01-01

    This report summarizes progress during the past year on maturing Boron-11 magnetic resonance imaging (MRI) methodology for noninvasive determination of BNCT agents (BSH) spatially in time. Three major areas are excerpted: (1) Boron-11 MRI of BSH distributions in a canine intracranial tumor model and the first human glioblastoma patient, (2) whole body Boron-11 MRI of BSH pharmacokinetics in a rat flank tumor model, and (3) penetration of gadolinium salts through the BBB as a function of tumor growth in the canine brain

  1. Diffusion-weighted imaging and dynamic contrast-enhanced MRI of experimental breast cancer bone metastases – A correlation study with histology

    Energy Technology Data Exchange (ETDEWEB)

    Merz, Maximilian [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Department of Hematology, Oncology and Rheumatology, Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120 Heidelberg (Germany); Seyler, Lisa; Bretschi, Maren; Semmler, Wolfhard [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Bäuerle, Tobias, E-mail: tobias.baeuerle@uk-erlangen.de [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Institute of Radiology, University Medical Center Erlangen, Palmsanlage 5, 90154 Erlangen (Germany)

    2015-04-15

    Purpose: To validate imaging parameters from diffusion-weighted imaging and dynamic contrast-enhanced MRI with immunohistology and to non-invasively assess microstructure of experimental breast cancer bone metastases. Materials and methods: Animals bearing breast cancer bone metastases were imaged in a clinical 1.5 T MRI scanner. HASTE sequences were performed to calculate apparent diffusion coefficients. Saturation recovery turbo FLASH sequences were conducted while infusing 0.1 mmol/l Gd–DTPA for dynamic contrast-enhanced MRI to quantify parameters amplitude A and exchange rate constant k{sub ep}. After imaging, bone metastases were analyzed immunohistologically. Results: We found correlations of the apparent diffusion coefficients from diffusion-weighted imaging with tumor cellularity as assessed with cell nuclei staining. Histological vessel maturity was correlated negatively with parameters A and k{sub ep} from dynamic contrast-enhanced MRI. Tumor size correlated inversely with cell density and vessel permeability as well as positively with mean vessel calibers. Parameters from the rim of bone metastases differed significantly from values of the center. Conclusion: In vivo diffusion-weighted imaging and dynamic contrast-enhanced MRI in experimental bone metastases provide information about tumor cellularity and vascularity and correlate well with immunohistology.

  2. Functional imaging in oncology. Clinical applications. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Luna, Antonio [Case Western Reserve Univ., Cleveland, OH (United States). Dept. of Radiology; MRI Health Time Group, Jaen (Spain); Vilanova, Joan C. [Girona Univ. (Spain). Clinica Girona - Hospital Sta. Caterina; Hygino da Cruz, L. Celso Jr. (ed.) [CDPI and IRM, Rio de Janeiro (Brazil). Dept. of Radiology; Rossi, Santiago E. [Centro de Diagnostico, Buenos Aires (Argentina)

    2014-06-01

    Easy-to-read manual on new functional imaging techniques in oncology. Explains current clinical applications and outlines future avenues. Includes numerous high-quality illustrations to highlight the major teaching points. In the new era of functional and molecular imaging, both currently available imaging biomarkers and biomarkers under development are expected to lead to major changes in the management of oncological patients. This two-volume book is a practical manual on the various imaging techniques capable of delivering functional information on cancer, including diffusion MRI, perfusion CT and MRI, dual-energy CT, spectroscopy, dynamic contrast-enhanced ultrasonography, PET, and hybrid modalities. This second volume considers the applications and benefits of these techniques in a wide range of tumor types, including their role in diagnosis, prediction of treatment outcome, and early evaluation of treatment response. Each chapter addresses a specific malignancy and is written by one or more acclaimed experts. The lucid text is complemented by numerous high-quality illustrations that highlight key features and major teaching points.

  3. Functional imaging in oncology. Clinical applications. Vol. 2

    International Nuclear Information System (INIS)

    Luna, Antonio; Vilanova, Joan C.

    2014-01-01

    Easy-to-read manual on new functional imaging techniques in oncology. Explains current clinical applications and outlines future avenues. Includes numerous high-quality illustrations to highlight the major teaching points. In the new era of functional and molecular imaging, both currently available imaging biomarkers and biomarkers under development are expected to lead to major changes in the management of oncological patients. This two-volume book is a practical manual on the various imaging techniques capable of delivering functional information on cancer, including diffusion MRI, perfusion CT and MRI, dual-energy CT, spectroscopy, dynamic contrast-enhanced ultrasonography, PET, and hybrid modalities. This second volume considers the applications and benefits of these techniques in a wide range of tumor types, including their role in diagnosis, prediction of treatment outcome, and early evaluation of treatment response. Each chapter addresses a specific malignancy and is written by one or more acclaimed experts. The lucid text is complemented by numerous high-quality illustrations that highlight key features and major teaching points.

  4. Magnetic resonance imaging and clinical features of glenoid labral flap tears

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, Jessica K.; Vinson, Emily N. [Duke University Hospital, Department of Radiology, Durham, NC (United States); Taylor, Dean C. [Duke University Hospital, Department of Orthopaedic Surgery, Durham, NC (United States)

    2017-08-15

    Displaced flaps of glenoid labral tissue are an uncommonly encountered finding on MRI of the shoulder, and are of unclear clinical significance. The purpose of this study is to describe the imaging characteristics of displaced glenoid labral flaps, evaluate for any common concomitant injuries, and identify the typical clinical presentation and management of patients with this lesion. This retrospective, observational study was approved by the institutional review board. Nineteen patients with flap-type tears of the labrum on preoperative MRI were identified. Each examination was retrospectively reviewed by two radiologists for size, location, and signal intensity of the displaced flap of tissue, in addition to any co-existing labrum or cartilage pathological conditions and clinical information. All displaced flaps extended from the inferior margin of the glenoid into the axillary recess. The average size of the visualized flap was 10.9 by 6.0 by 2.6 mm. Seventy percent of the flaps had signal intensity isointense to labrum and hypointense to hyaline cartilage on T2-weighted images. All 19 patients had concomitant labral pathological conditions and 63% had cartilage defects, visualized on MRI. Clinical evidence of shoulder instability was seen in 83% of patients, and 67% were managed surgically. Glenoid labral flap tears have distinct imaging characteristics that may aid in their identification. Their presence should prompt careful evaluation of the glenoid articular cartilage. Recognition of a labral flap tear may have clinical importance, as 83% of patients with this finding demonstrated clinical evidence of shoulder instability, often requiring surgical intervention. (orig.)

  5. Magnetic resonance imaging and clinical features of glenoid labral flap tears

    International Nuclear Information System (INIS)

    Stewart, Jessica K.; Vinson, Emily N.; Taylor, Dean C.

    2017-01-01

    Displaced flaps of glenoid labral tissue are an uncommonly encountered finding on MRI of the shoulder, and are of unclear clinical significance. The purpose of this study is to describe the imaging characteristics of displaced glenoid labral flaps, evaluate for any common concomitant injuries, and identify the typical clinical presentation and management of patients with this lesion. This retrospective, observational study was approved by the institutional review board. Nineteen patients with flap-type tears of the labrum on preoperative MRI were identified. Each examination was retrospectively reviewed by two radiologists for size, location, and signal intensity of the displaced flap of tissue, in addition to any co-existing labrum or cartilage pathological conditions and clinical information. All displaced flaps extended from the inferior margin of the glenoid into the axillary recess. The average size of the visualized flap was 10.9 by 6.0 by 2.6 mm. Seventy percent of the flaps had signal intensity isointense to labrum and hypointense to hyaline cartilage on T2-weighted images. All 19 patients had concomitant labral pathological conditions and 63% had cartilage defects, visualized on MRI. Clinical evidence of shoulder instability was seen in 83% of patients, and 67% were managed surgically. Glenoid labral flap tears have distinct imaging characteristics that may aid in their identification. Their presence should prompt careful evaluation of the glenoid articular cartilage. Recognition of a labral flap tear may have clinical importance, as 83% of patients with this finding demonstrated clinical evidence of shoulder instability, often requiring surgical intervention. (orig.)

  6. VISARTTM superconducting MRI system

    International Nuclear Information System (INIS)

    Usui, Yoshiyuki; Goro, Takehiko; Yamagata, Hitoshi.

    1995-01-01

    We have developed VISART TM , a 1.5 T high-field magnetic resonance imaging (MRI) system based on technology developed for both the FLEXART TM (0.5T) and MRT-200/GP (1.5T) systems as the first and second products, respectively, of a new series of MRI systems. VISART TM is a newly coined word combining VISion and state-of-the-ART. A higher power gradient system and new high-speed imaging techniques have been developed to meet the market demand for higher resolution images and shorter scan times. The product concepts of VISART TM are high image quality, high patient throughput, flexible clinical application, and ease of use, all of which are essential features for an MRI system in the high-field MRI market segment. (author)

  7. Functional and molecular imaging with MRI: potential applications in paediatric radiology

    International Nuclear Information System (INIS)

    Arthurs, Owen J.; Gallagher, Ferdia A.

    2011-01-01

    MRI is a very versatile tool for noninvasive imaging and it is particularly attractive as an imaging technique in paediatric patients given the absence of ionizing radiation. Recent advances in the field of MRI have enabled tissue function to be probed noninvasively, and increasingly MRI is being used to assess cellular and molecular processes. For example, dynamic contrast-enhanced MRI has been used to assess tissue vascularity, diffusion-weighted imaging can quantify molecular movements of water in tissue compartments and MR spectroscopy provides a quantitative assessment of metabolite levels. A number of targeted contrast agents have been developed that bind specifically to receptors on the vascular endothelium or cell surface and there are several MR methods for labelling cells and tracking cellular movements. Hyperpolarization techniques have the capability of massively increasing the sensitivity of MRI and these have been used to image tissue pH, successful response to drug treatment as well as imaging the microstructure of the lungs. Although there are many challenges to be overcome before these techniques can be translated into routine paediatric imaging, they could potentially be used to aid diagnosis, predict disease outcome, target biopsies and determine treatment response noninvasively. (orig.)

  8. Diagnosis of deep endometriosis: clinical examination, ultrasonography, magnetic resonance imaging, and other techniques.

    Science.gov (United States)

    Bazot, Marc; Daraï, Emile

    2017-12-01

    The aim of the present review was to evaluate the contribution of clinical examination and imaging techniques, mainly transvaginal sonography and magnetic resonance imaging (MRI) to diagnose deep infiltrating (DE) locations using prisma statement recommendations. Clinical examination has a relative low sensitivity and specificity to diagnose DE. Independently of DE locations, for all transvaginal sonography techniques a pooled sensitivity and specificity of 79% and 94% are observed approaching criteria for a triage test. Whatever the protocol and MRI devices, the pooled sensitivity and specificity for pelvic endometriosis diagnosis were 94% and 77%, respectively. For rectosigmoid endometriosis, pooled sensitivity and specificity of MRI were 92% and 96%, respectively fulfilling criteria of replacement test. In conclusion, advances in imaging techniques offer high sensitivity and specificity to diagnose DE with at least triage value and for rectosigmoid endometriosis replacement value imposing a revision of the concept of laparoscopy as the gold standard. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  9. Variability of carotid artery measurements on 3-Tesla MRI and its impact on sample size calculation for clinical research.

    Science.gov (United States)

    Syed, Mushabbar A; Oshinski, John N; Kitchen, Charles; Ali, Arshad; Charnigo, Richard J; Quyyumi, Arshed A

    2009-08-01

    Carotid MRI measurements are increasingly being employed in research studies for atherosclerosis imaging. The majority of carotid imaging studies use 1.5 T MRI. Our objective was to investigate intra-observer and inter-observer variability in carotid measurements using high resolution 3 T MRI. We performed 3 T carotid MRI on 10 patients (age 56 +/- 8 years, 7 male) with atherosclerosis risk factors and ultrasound intima-media thickness > or =0.6 mm. A total of 20 transverse images of both right and left carotid arteries were acquired using T2 weighted black-blood sequence. The lumen and outer wall of the common carotid and internal carotid arteries were manually traced; vessel wall area, vessel wall volume, and average wall thickness measurements were then assessed for intra-observer and inter-observer variability. Pearson and intraclass correlations were used in these assessments, along with Bland-Altman plots. For inter-observer variability, Pearson correlations ranged from 0.936 to 0.996 and intraclass correlations from 0.927 to 0.991. For intra-observer variability, Pearson correlations ranged from 0.934 to 0.954 and intraclass correlations from 0.831 to 0.948. Calculations showed that inter-observer variability and other sources of error would inflate sample size requirements for a clinical trial by no more than 7.9%, indicating that 3 T MRI is nearly optimal in this respect. In patients with subclinical atherosclerosis, 3 T carotid MRI measurements are highly reproducible and have important implications for clinical trial design.

  10. MRI of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Kauczor, Hans-Ulrich (ed.) [University Clinic Heidelberg (Germany). Diagnostic and Interventional Radiology

    2009-07-01

    For a long time, only chest X-ray and CT were used to image lung structure, while nuclear medicine was employed to assess lung function. During the past decade significant developments have been achieved in the field of magnetic resonance imaging (MRI), enabling MRI to enter the clinical arena of chest imaging. Standard protocols can now be implemented on up-to-date scanners, allowing MRI to be used as a first-line imaging modality for various lung diseases, including cystic fibrosis, pulmonary hypertension and even lung cancer. The diagnostic benefits stem from the ability of MRI to visualize changes in lung structure while simultaneously imaging different aspects of lung function, such as perfusion, respiratory motion, ventilation and gas exchange. On this basis, novel quantitative surrogates for lung function can be obtained. This book provides a comprehensive overview of how to use MRI for imaging of lung disease. Special emphasis is placed on benign diseases requiring regular monitoring, given that it is patients with these diseases who derive the greatest benefit from the avoidance of ionizing radiation. (orig.)

  11. [Time consumption and quality of an automated fusion tool for SPECT and MRI images of the brain].

    Science.gov (United States)

    Fiedler, E; Platsch, G; Schwarz, A; Schmiedehausen, K; Tomandl, B; Huk, W; Rupprecht, Th; Rahn, N; Kuwert, T

    2003-10-01

    Although the fusion of images from different modalities may improve diagnostic accuracy, it is rarely used in clinical routine work due to logistic problems. Therefore we evaluated performance and time needed for fusing MRI and SPECT images using a semiautomated dedicated software. PATIENTS, MATERIAL AND METHOD: In 32 patients regional cerebral blood flow was measured using (99m)Tc ethylcystein dimer (ECD) and the three-headed SPECT camera MultiSPECT 3. MRI scans of the brain were performed using either a 0,2 T Open or a 1,5 T Sonata. Twelve of the MRI data sets were acquired using a 3D-T1w MPRAGE sequence, 20 with a 2D acquisition technique and different echo sequences. Image fusion was performed on a Syngo workstation using an entropy minimizing algorithm by an experienced user of the software. The fusion results were classified. We measured the time needed for the automated fusion procedure and in case of need that for manual realignment after automated, but insufficient fusion. The mean time of the automated fusion procedure was 123 s. It was for the 2D significantly shorter than for the 3D MRI datasets. For four of the 2D data sets and two of the 3D data sets an optimal fit was reached using the automated approach. The remaining 26 data sets required manual correction. The sum of the time required for automated fusion and that needed for manual correction averaged 320 s (50-886 s). The fusion of 3D MRI data sets lasted significantly longer than that of the 2D MRI data. The automated fusion tool delivered in 20% an optimal fit, in 80% manual correction was necessary. Nevertheless, each of the 32 SPECT data sets could be merged in less than 15 min with the corresponding MRI data, which seems acceptable for clinical routine use.

  12. Lateral epicondylitis: Associations of MR imaging and clinical assessments with treatment options in patients receiving conservative and arthroscopic managements.

    Science.gov (United States)

    Jeon, Ji Young; Lee, Min Hee; Jeon, In-Ho; Chung, Hye Won; Lee, Sang Hoon; Shin, Myung Jin

    2018-03-01

    We assessed the implications of MR imaging with clinical history in lateral epicondylitis management by evaluating imaging and clinical features in patients with lateral epicondylitis treated conservatively or operatively. Sixty patients with lateral epicondylitis treated conservatively (n = 38) or operatively (n = 22) from 2011-2015 were included. MR imaging findings of common extensor tendon (CET), lateral collateral ligament (LCL) complex, muscle oedema, ulnar nerve and elbow joint were reviewed. Clinical data recorded were frequency, duration and intensity of pain, history of trauma and injection therapy, range of motion. MRI-assessed CET and LCL complex abnormalities, muscle oedema, radiocapitellar joint widening, joint effusion/synovitis, pain frequency and intensity differed significantly between the two groups (p lateral epicondylitis. • MRI can reflect different disease severity between patients treated conservatively/operatively. • CET abnormality, muscle oedema were major MRI findings with operative treatment. • Patients in operative group were more likely to experience persistent pain. • MRI plus clinical symptoms could facilitate appropriate management for lateral epicondylitis.

  13. Multi-modal image registration: matching MRI with histology

    Science.gov (United States)

    Alic, Lejla; Haeck, Joost C.; Klein, Stefan; Bol, Karin; van Tiel, Sandra T.; Wielopolski, Piotr A.; Bijster, Magda; Niessen, Wiro J.; Bernsen, Monique; Veenland, Jifke F.; de Jong, Marion

    2010-03-01

    Spatial correspondence between histology and multi sequence MRI can provide information about the capabilities of non-invasive imaging to characterize cancerous tissue. However, shrinkage and deformation occurring during the excision of the tumor and the histological processing complicate the co registration of MR images with histological sections. This work proposes a methodology to establish a detailed 3D relation between histology sections and in vivo MRI tumor data. The key features of the methodology are a very dense histological sampling (up to 100 histology slices per tumor), mutual information based non-rigid B-spline registration, the utilization of the whole 3D data sets, and the exploitation of an intermediate ex vivo MRI. In this proof of concept paper, the methodology was applied to one tumor. We found that, after registration, the visual alignment of tumor borders and internal structures was fairly accurate. Utilizing the intermediate ex vivo MRI, it was possible to account for changes caused by the excision of the tumor: we observed a tumor expansion of 20%. Also the effects of fixation, dehydration and histological sectioning could be determined: 26% shrinkage of the tumor was found. The annotation of viable tissue, performed in histology and transformed to the in vivo MRI, matched clearly with high intensity regions in MRI. With this methodology, histological annotation can be directly related to the corresponding in vivo MRI. This is a vital step for the evaluation of the feasibility of multi-spectral MRI to depict histological groundtruth.

  14. AUTOMATED CLASSIFICATION AND SEGREGATION OF BRAIN MRI IMAGES INTO IMAGES CAPTURED WITH RESPECT TO VENTRICULAR REGION AND EYE-BALL REGION

    Directory of Open Access Journals (Sweden)

    C. Arunkumar

    2014-05-01

    Full Text Available Magnetic Resonance Imaging (MRI images of the brain are used for detection of various brain diseases including tumor. In such cases, classification of MRI images captured with respect to ventricular and eye ball regions helps in automated location and classification of such diseases. The methods employed in the paper can segregate the given MRI images of brain into images of brain captured with respect to ventricular region and images of brain captured with respect to eye ball region. First, the given MRI image of brain is segmented using Particle Swarm Optimization (PSO algorithm, which is an optimized algorithm for MRI image segmentation. The algorithm proposed in the paper is then applied on the segmented image. The algorithm detects whether the image consist of a ventricular region or an eye ball region and classifies it accordingly.

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... provides detailed images of blood vessels in the brain—often without the need for contrast material. See the MRA page for more information. MRI can detect stroke at a very early stage by mapping the motion of water molecules in the tissue. ...

  16. Clinical findings just after return to play predict hamstring re-injury, but baseline MRI findings do not

    NARCIS (Netherlands)

    de Vos, Robert-Jan; Reurink, Gustaaf; Goudswaard, Gert-Jan; Moen, Maarten H.; Weir, Adam; Tol, Johannes L.

    2014-01-01

    Acute hamstring re-injuries are common and hard to predict. The aim of this study was to investigate the association between clinical and imaging findings and the occurrence of hamstring re-injuries. We obtained baseline data (clinical and MRI findings) of athletes who sustained an acute hamstring

  17. The OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging (MRI) Scoring System: Updated Recommendations by the OMERACT MRI in Arthritis Working Group.

    Science.gov (United States)

    Østergaard, Mikkel; Peterfy, Charles G; Bird, Paul; Gandjbakhch, Frédérique; Glinatsi, Daniel; Eshed, Iris; Haavardsholm, Espen A; Lillegraven, Siri; Bøyesen, Pernille; Ejbjerg, Bo; Foltz, Violaine; Emery, Paul; Genant, Harry K; Conaghan, Philip G

    2017-11-01

    The Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis (RA) Magnetic Resonance Imaging (MRI) scoring system (RAMRIS), evaluating bone erosion, bone marrow edema/osteitis, and synovitis, was introduced in 2002, and is now the standard method of objectively quantifying inflammation and damage by MRI in RA trials. The objective of this paper was to identify subsequent advances and based on them, to provide updated recommendations for the RAMRIS. MRI studies relevant for RAMRIS and technical and scientific advances were analyzed by the OMERACT MRI in Arthritis Working Group, which used these data to provide updated considerations on image acquisition, RAMRIS definitions, and scoring systems for the original and new RA pathologies. Further, a research agenda was outlined. Since 2002, longitudinal studies and clinical trials have documented RAMRIS variables to have face, construct, and criterion validity; high reliability and sensitivity to change; and the ability to discriminate between therapies. This has enabled RAMRIS to demonstrate inhibition of structural damage progression with fewer patients and shorter followup times than has been possible with conventional radiography. Technical improvements, including higher field strengths and improved pulse sequences, allow higher image resolution and contrast-to-noise ratio. These have facilitated development and validation of scoring methods of new pathologies: joint space narrowing and tenosynovitis. These have high reproducibility and moderate sensitivity to change, and can be added to RAMRIS. Combined scores of inflammation or joint damage may increase sensitivity to change and discriminative power. However, this requires further research. Updated 2016 RAMRIS recommendations and a research agenda were developed.

  18. Role of 3T multiparametric-MRI with BOLD hypoxia imaging for diagnosis and post therapy response evaluation of postoperative recurrent cervical cancers

    International Nuclear Information System (INIS)

    Mahajan, Abhishek; Engineer, Reena; Chopra, Supriya; Mahanshetty, Umesh; Juvekar, S.L.; Shrivastava, S.K.; Desekar, Naresh; Thakur, M.H.

    2015-01-01

    •In operated cervix cancer, the accuracy of diagnosing vaginal vault/local recurrent lesions was higher at combined multiparametric MR imaging and conventional MR imaging (100%) than at conventional MR imaging (70%) or multiparametric MR imaging (96.7%) alone.•We found a significant correlation between percentage tumor regression and pre-treatment parameters: NEI (p = 0.02), the maximum slope (p = 0.04), mADC value (p = 0.001) and amount of hypoxic fraction present in the pretherapy MRI (p = 0.01).•Multiparametric and BOLD hypoxia MR Imaging are feasible and reliable in diagnosing post-operative recurrence in cervical cancer and should be applied when there is clinical suspicion of post-operative recurrence.•Quantitative image features obtained at multiparametric-MRI with BOLD hypoxia imaging has potential to be an appropriate and reliable biologic target for radiation dose painting to optimize therapy in future. In operated cervix cancer, the accuracy of diagnosing vaginal vault/local recurrent lesions was higher at combined multiparametric MR imaging and conventional MR imaging (100%) than at conventional MR imaging (70%) or multiparametric MR imaging (96.7%) alone. We found a significant correlation between percentage tumor regression and pre-treatment parameters: NEI (p = 0.02), the maximum slope (p = 0.04), mADC value (p = 0.001) and amount of hypoxic fraction present in the pretherapy MRI (p = 0.01). Multiparametric and BOLD hypoxia MR Imaging are feasible and reliable in diagnosing post-operative recurrence in cervical cancer and should be applied when there is clinical suspicion of post-operative recurrence. Quantitative image features obtained at multiparametric-MRI with BOLD hypoxia imaging has potential to be an appropriate and reliable biologic target for radiation dose painting to optimize therapy in future. To assess the diagnostic value of multiparametric-MRI (MPMRI) with hypoxia imaging as a functional marker for characterizing and detecting

  19. Integration of Medical Imaging Including Ultrasound into a New Clinical Anatomy Curriculum

    Science.gov (United States)

    Moscova, Michelle; Bryce, Deborah A.; Sindhusake, Doungkamol; Young, Noel

    2015-01-01

    In 2008 a new clinical anatomy curriculum with integrated medical imaging component was introduced into the University of Sydney Medical Program. Medical imaging used for teaching the new curriculum included normal radiography, MRI, CT scans, and ultrasound imaging. These techniques were incorporated into teaching over the first two years of the…

  20. MR imaging assessment of clinical problems in rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Narvaez, Jose A.; Roca, Yolanda; Aguilera, Carlos [Department of CT and MR Imaging, Hospital Duran i Reynals, Universitaria de Bellvitge, Barcelona (Spain); Narvaez, Javier [Department of Medicine, Delfos Medical Center, Barcelona (Spain)

    2002-07-01

    Although MR imaging has been increasingly recognized as a useful tool in the diagnosis of early rheumatoid arthritis (RA) and in the assessment of disease activity, these applications have not yet been usually included in the routine management of this condition. Our goal is to review the current role of MRI in the everyday clinical management of patients with RA. The usefulness of MRI in the evaluation of articular and para-articular changes in specific locations, mainly the craniocervical region and the temporomandibular joint, are reviewed. Clinical problems derived from local extra-articular involvement, such as tenosynovitis, ''rice-bodies'' bursitis, and Baker's cyst rupture, are also described. Finally, we also review the value of MRI in evaluation of some complications of RA such as tendinous rupture, osteonecrosis, stress fracture, and septic arthritis/osteomyelitis. (orig.)

  1. The cranial MRI in severe cerebral palsy; A comparative study with clinical data

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Kazutaka; Itoh, Masahiro; Fueki, Noboru; Hirasawa, Kyoko; Suzuki, Noriko; Kurata, Kiyoko (Metropolitan Medical Center of the Severely Handicapped, Tokyo (Japan)); Sato, Junichi; Morimatsu, Yoshio; Yagishita, Akira

    1993-09-01

    The magnetic resonance examination was performed in 38 patients with severe cerebral palsy (CP; 15 males and 23 females) who had both motor delay (unable to move anywhere) and mental retardation (I.Q. or D.Q. below 30). Neuroimaging findings were compared with the CP type, etiology, and grade of understanding of language. Cranial magnetic resonance imagings (MRI) in CP were divided into five types. In type 1, nine predominantly showed cyst-liked ventricles and periventricular hyperintensity on T[sub 2]-weighted imaging (PVH) and only scarred basal ganglia and thalamus were visible. All suffered from neonatal asphyxia and the clinical type was rigospastic tetraplegia (RST). In type 2, eleven predominantly showed PVH and hyperintensity on T[sub 2]-weighted (HT2) in basal ganglia and thalamus. All suffered from neonatal asphyxia and the clinical type was RST or rigospastic diplegia. In type 3, five showed PVH and three had cortical atrophy. All suffered from neonatal asphyxia and the clinical type was spastic diplegia. In type 4, four predominantly showed HT2 in putamen and thalamus. Three had cortical atrophy. All suffered from neonatal asphyxia. The clinical type was athetotic CP (ATH). In type 5, nine predominantly showed HT2 in globus pallidus. Four had cortical atrophy and two had hippocampal atrophy. All suffered from neonatal jaundice and the clinical type was ATH. All patients who suffered from neonatal asphyxia and spastic CP had MRI in PVH. All patients who suffered from neonatal asphyxia and ATH showed HT2 in putamen and thalamus. Almost patients who suffered from neonatal jaundice and ATH showed HT2 in globus pallidus. With athetotic CP, cases with atrophy of the cerebral cortex and/or hippocampus were lower grade of understanding of language than no atrophy of both. The results of studies of MRI are in agreement with neuropathological findings. (author).

  2. The evaluation of FDG-PET imaging for epileptogenic focus localization in patients with MRI positive and MRI negative temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Gok, Beril; Jallo, George; Hayeri, Reza; Wahl, Richard; Aygun, Nafi

    2013-01-01

    We studied the contribution of interictal FDG-PET ([18 F] fluorodeoxyglucose-positron emission tomography) in epileptic focus identification in temporal lobe epilepsy patients with positive, equivocal and negative magnetic resonance imaging (MRI). Ninety-eight patients who underwent surgical treatment for drug resistant temporal lobe epilepsy after neuropsychological evaluation, scalp video EEG monitoring, FDG-PET, MRI and/or long-term intracranial EEG and with >12 months clinical follow-up were included in this study. FDG-PET findings were compared to MRI, histopathology, scalp video EEG and long-term intracranial EEG monitoring. FDG-PET lateralized the seizure focus in 95 % of MRI positive, 69 % of MRI equivocal and 84 % of MRI negative patients. There was no statistically significant difference between the surgical outcomes among the groups with Engel class I and II outcomes achieved in 86 %, 86 %, 84 % of MRI positive, equivocal and negative temporal lobe epilepsy patients, respectively. The patients with positive unilateral FDG-PET demonstrated excellent postsurgical outcomes, with 96 % Engel class I and II. Histopathology revealed focal lesions in 75 % of MRI equivocal, 84 % of MRI positive, and 23 % of MRI negative temporal lobe epilepsy cases. FDG-PET is an accurate noninvasive method in lateralizing the epileptogenic focus in temporal lobe epilepsy, especially in patients with normal or equivocal MRIs, or non-lateralized EEG monitoring. Very subtle findings in MRI are often associated with histopathological lesions and should be described in MRI reports. The patients with negative or equivocal MRI temporal lobe epilepsy are good surgical candidates with comparable postsurgical outcomes to patients with MRI positive temporal lobe epilepsy. (orig.)

  3. The evaluation of FDG-PET imaging for epileptogenic focus localization in patients with MRI positive and MRI negative temporal lobe epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Gok, Beril [Drexel University, Department of Radiology, Mercy Catholic Medical Center, Philadelphia, PA (United States); Johns Hopkins University, Division of Nuclear Medicine, Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Jallo, George [Johns Hopkins University, Department of Neurosurgery, Baltimore, MD (United States); Hayeri, Reza [Drexel University, Department of Radiology, Mercy Catholic Medical Center, Philadelphia, PA (United States); Wahl, Richard [Johns Hopkins University, Division of Nuclear Medicine, Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Aygun, Nafi [Johns Hopkins University, Division of Neuroradiology, Department of Radiology and Radiological Sciences, Baltimore, MD (United States)

    2013-05-15

    We studied the contribution of interictal FDG-PET ([18 F] fluorodeoxyglucose-positron emission tomography) in epileptic focus identification in temporal lobe epilepsy patients with positive, equivocal and negative magnetic resonance imaging (MRI). Ninety-eight patients who underwent surgical treatment for drug resistant temporal lobe epilepsy after neuropsychological evaluation, scalp video EEG monitoring, FDG-PET, MRI and/or long-term intracranial EEG and with >12 months clinical follow-up were included in this study. FDG-PET findings were compared to MRI, histopathology, scalp video EEG and long-term intracranial EEG monitoring. FDG-PET lateralized the seizure focus in 95 % of MRI positive, 69 % of MRI equivocal and 84 % of MRI negative patients. There was no statistically significant difference between the surgical outcomes among the groups with Engel class I and II outcomes achieved in 86 %, 86 %, 84 % of MRI positive, equivocal and negative temporal lobe epilepsy patients, respectively. The patients with positive unilateral FDG-PET demonstrated excellent postsurgical outcomes, with 96 % Engel class I and II. Histopathology revealed focal lesions in 75 % of MRI equivocal, 84 % of MRI positive, and 23 % of MRI negative temporal lobe epilepsy cases. FDG-PET is an accurate noninvasive method in lateralizing the epileptogenic focus in temporal lobe epilepsy, especially in patients with normal or equivocal MRIs, or non-lateralized EEG monitoring. Very subtle findings in MRI are often associated with histopathological lesions and should be described in MRI reports. The patients with negative or equivocal MRI temporal lobe epilepsy are good surgical candidates with comparable postsurgical outcomes to patients with MRI positive temporal lobe epilepsy. (orig.)

  4. Imaging tools to study pharmacology: functional MRI on small rodents

    OpenAIRE

    Elisabeth eJonckers; Disha eShah; Julie eHamaide; Marleen eVerhoye; Annemie eVan Der Linden

    2015-01-01

    Functional Magnetic Resonance Imaging (fMRI) is an excellent tool to study the effect of pharmacological modulations on brain function in a non-invasive and longitudinal manner. We introduce several blood oxygenation level dependent (BOLD) fMRI techniques, including resting state (rsfMRI), stimulus-evoked (st-fMRI), and pharmacological MRI (phMRI). Respectively, these techniques permit the assessment of functional connectivity during rest as well as brain activation triggered by sensory stimu...

  5. MRI methods for pulmonary ventilation and perfusion imaging; Methoden der MRT zur Ventilations- und Perfusionsbildgebung der Lunge

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland); Bauman, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin - Radiologische Physik, Basel (Switzerland)

    2016-02-15

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O{sub 2}-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies. (orig.) [German] Die separate Beurteilung von Atemmechanik, Gasaustauschprozessen und Lungenzirkulation ist wesentlich fuer die Diagnose und Therapie von Lungenerkrankungen. Klinische Lungenfunktionstests sind aufgrund ihrer zumeist nur globalen Aussage oft nicht hinreichend spezifisch in der Differenzialdiagnostik oder eingeschraenkt sensitiv bei der

  6. Assessment of paramedian thalamic infarcts: MR imaging, clinical features and prognosis

    International Nuclear Information System (INIS)

    Weidauer, Stefan; Zanella, Friedhelm E.; Lanfermann, Heinrich; Nichtweiss, Michael

    2004-01-01

    Considering the highly variable vascular supply of the thalamic nuclei, MRI and clinical syndromes can be heterogeneous in ischemic diseases. We attempt to determine MRI pattern and to analyse neurological features and prognosis of paramedian infarcts. In a prospective case series within 5 years from 1999 to 2003, MRI, MRA and clinical symptoms of 38 consecutive patients were analysed. The inferomedial (posterior thalamoperforating artery) territory was affected in 89%, and lesions in the anterolateral (tuberothalamic artery) territory occurred in 42%. However, definite attribution to anterolateral or inferomedial territories was not possible in 13%. Neurological manifestations were somnolence (87%), hemisyndromes (79%), cognitive deficits (58%), oculomotor nerve palsies (53%) and vertical gaze palsies (39%). The most common aetiologies were cardiac embolism (42%), intraarterial embolism (16%), small vessel disease (13%) and large artery arteriosclerosis (13%). Pathological MRA findings were encountered in 55%, and in 18%, lesions were only visible on diffusion-weighted imaging. Correlation of MRI pattern and neurological symptoms points out anterolateral thalamic lesions as the cause of amnestic deficits. Intracranial MRA allows a non-invasive prediction of basilar tip occlusion. Our results underline the necessity of additional diffusion-weighted imaging in detecting small thalamic and midbrain lesions. (orig.)

  7. Wilson's disease: cranial MRI observations and clinical correlation

    International Nuclear Information System (INIS)

    Sinha, S.; Taly, A.B.; Prashanth, L.K.; Venugopal, K.S.; Arunodaya, G.R.; Swamy, H.S.; Ravishankar, S.; Vasudev, M.K.

    2006-01-01

    Study of MRI changes may be useful in diagnosis, prognosis and better understanding of the pathophysiology of Wilson's disease (WD). We aimed to describe and correlate the MRI abnormalities of the brain with clinical features in WD. MRI evaluation was carried out in 100 patients (57 males, 43 females; mean age 19.3±8.9 years) using standard protocols. All but 18 patients were on de-coppering agents. Their history, clinical manifestations and scores for severity of disease were noted. The mean duration of illness and treatment were 8.3±10.8 years and 7.5±7.1 years respectively. MRI of the brain was abnormal in all the 93 symptomatic patients. The most conspicuous observations were atrophy of the cerebrum (70%), brainstem (66%) and cerebellum (52%). Signal abnormalities were also noted: putamen (72%), caudate (61%), thalami (58%), midbrain (49%), pons (20%), cerebral white matter (25%), cortex (9%), medulla (12%) and cerebellum (10%). The characteristic T2-W globus pallidal hypointensity (34%), ''Face of giant panda'' sign (12%), T1-W striatal hyperintensity (6%), central pontine myelinosis (7%), and bright claustral sign (4%) were also detected. MRI changes correlated with disease severity scores (P<0.001) but did not correlate with the duration of illness. MRI changes were universal but diverse and involved almost all the structures of the brain in symptomatic patients. A fair correlation between MRI observations and various clinical features provides an explanation for the protean manifestations of the disease. (orig.)

  8. Clinical implications of increased use of MRI in TIA.

    Science.gov (United States)

    Kvistad, C E; Thomassen, L; Waje-Andreassen, U; Moen, G; Logallo, N; Naess, H

    2013-07-01

    Transient ischemic attack has been redefined as a tissue-based diagnosis and MRI recommended as the preferred imaging modality. We aimed to investigate whether an increased use of MRI leads to a decrease in the proportion of TIA as compared to cerebral infarction. We also sought to see whether DWI-positive patients with transient ischemic symptoms TIA patients in terms of performed diagnostic investigations and clinical characteristics. Patients admitted with cerebral infarction or TIA in the period 2006-2011 were prospectively registered. The use of MRI in patients with transient ischemic symptoms TIA were annually recorded. DWI-positive and DWI-negative patients with transient ischemic symptoms TIA as compared to cerebral infarction decreased from 12.2% in 2006-2008 to 8.3% in 2009-2011 (P = 0.002). DWI-positive patients were more often examined with 24-h Holter monitoring (P TIA definition resulted in a decrease in the proportion of TIA at discharge as compared to cerebral infarction. DWI-positive patients had a more extensive cardiac work-up and were associated with lower age and prior myocardial infarction. © 2012 John Wiley & Sons A/S.

  9. Magnetic Resonance Imaging of Patients With Chronic Lateral Epicondylitis: Is There a Relationship Between Magnetic Resonance Imaging Abnormalities of the Common Extensor Tendon and the Patient's Clinical Symptom?

    Science.gov (United States)

    Qi, Liang; Zhang, Yu-Dong; Yu, Rong-Bin; Shi, Hai-Bin

    2016-02-01

    The aim of the study is to determine the inter-reliability and intra-observer reliability of magnetic resonance imaging (MRI) for lateral epicondylitis and investigate whether there is a potential relationship between MRI abnormalities of the common extensor tendon (CET) and its clinical symptom.The study group comprised 96 consecutive patients (46 men and 50 women) with a clinical diagnosis of chronic lateral epicondylitis, which were examined on 3.0 T MR. An MRI scoring system was used to grade the degree of tendinopahty. Three independent musculoskeletal radiologists, who were blinded to the patients' clinical information, scored images separately. Clinical symptoms were assessed using the Patient-Rated Tennis Elbow Evaluation (PRTEE).Of all the patients, total 96 elbows had MRI-assessed tendinopathy, including 38 (39.6%) with grade 1, 31 (32.3%) with grade 2, and 27 (28.1%) with grade 3. Inter-observer reliability and intra-observer agreement for MRI interpretation of the grades of tendinopathy was good, and a positive correlation between the grades of tendinopathy and PRTEE was determined.MRI is a reliable tool in determining radiological severity of chronical lateral epicondylitis. The severity of MR signal changes positively correlate with the patient's clinical symptom.

  10. Imaging children suffering from lymphoma: an evaluation of different 18F-FDG PET/MRI protocols compared to whole-body DW-MRI.

    Science.gov (United States)

    Kirchner, Julian; Deuschl, Cornelius; Schweiger, Bernd; Herrmann, Ken; Forsting, Michael; Buchbender, Christian; Antoch, Gerald; Umutlu, Lale

    2017-09-01

    The objectives of this study were to evaluate and compare the diagnostic potential of different PET/MRI reading protocols, entailing non-enhanced / contrast-enhanced and diffusion-weighted 18 F-FDG PET/MR imaging and whole-body diffusion-weighted MRI for lesion detection and determination of the tumor stage in pediatric lymphoma patients. A total of 28 18 F-FDG PET/MRI datasets were included for analysis of four different reading protocols: (1) PET/MRI utilizing sole unenhanced T2w and T1w imaging, (2) PET/MRI utilizing additional contrast enhanced sequences, (3) PET/MR imaging utilizing unenhanced, contrast enhanced and DW imaging or (4) WB-DW-MRI. Statistical analyses were performed on a per-patient and a per-lesion basis. Follow-up and prior examinations as well as histopathology served as reference standards. PET/MRI correctly identified all 17 examinations with active lymphoma disease, while WB-DW-MRI correctly identified 15/17 examinations. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy were 96%, 96.5%, 97%, 95%, and 96% for PET/MRI 1 ; 97%, 96.5%, 97%, 96.5%, and 97% for PET/MRI 2 ; 97%, 96.5%, 97%, 96.5%, and 97% for PET/MRI 3 and 77%, 96%, 96%, 78.5% and 86% for MRI-DWI. 18 F-FDG PET/MRI is superior to WB-DW-MRI in staging pediatric lymphoma patients. Neither application of contrast media nor DWI leads to a noticeable improvement of the diagnostic accuracy of PET/MRI. Thus, unenhanced PET/MRI may play a crucial role for the diagnostic work-up of pediatric lymphoma patients in the future.

  11. Health economic assessment of Gd-EOB-DTPA MRI versus ECCM-MRI and multi-detector CT for diagnosis of hepatocellular carcinoma in China

    Science.gov (United States)

    He, Xiaoning; Holtorf, Anke-Peggy; Rinde, Harald; Xie, Shuangshuang; Shen, Wen; Hou, Jiancun; Li, Xuehua; Li, Ziping; Lai, Jiaming; Wang, Yuting; Zhang, Lin; Wang, Jian; Li, Xuesong; Ma, Kuansheng; Ye, Feng; Ouyang, Han; Zhao, Hong

    2018-01-01

    Limited data exists in China on the comparative cost of gadolinium ethoxybenzyl diethylenetriamine magnetic resonance imaging (Gd-EOB-DTPA-MRI) with other imaging techniques. This study compared the total cost of Gd-EOB-DTPA-MRI with multidetector computed tomography (MDCT) and extracellular contrast media–enhanced MRI (ECCM-MRI) as initial imaging procedures in patients with suspected hepatocellular carcinoma (HCC). We developed a decision-tree model on the basis of the Chinese clinical guidelines for HCC, which was validated by clinical experts from China. The model compared the diagnostic accuracy and costs of alternative initial imaging procedures. Compared with MDCT and ECCM-MRI, Gd-EOB-DTPA-MRI imaging was associated with higher rates of diagnostic accuracy, i.e. higher proportions of true positives (TP) and true negatives (TN) with lower false positives (FP). Total diagnosis and treatment cost per patient after the initial Gd-EOB-DTPA-MRI evaluation was similar to MDCT (¥30,360 vs. ¥30,803) and lower than that reported with ECCM-MRI (¥30,360 vs. ¥31,465). Lower treatment cost after initial Gd-EOB-DTPA-MRI was driven by reduced utilization of confirmatory diagnostic procedures and unnecessary treatments. The findings reported that Gd-EOB-DTPA-MRI offered higher diagnostic accuracy compared with MDCT and ECCM-MRI at a comparable cost, which indicates Gd-EOB-DTPA-MRI could be the preferred initial imaging procedure for the diagnosis of HCC in China. PMID:29324837

  12. Health economic assessment of Gd-EOB-DTPA MRI versus ECCM-MRI and multi-detector CT for diagnosis of hepatocellular carcinoma in China.

    Directory of Open Access Journals (Sweden)

    Xiaoning He

    Full Text Available Limited data exists in China on the comparative cost of gadolinium ethoxybenzyl diethylenetriamine magnetic resonance imaging (Gd-EOB-DTPA-MRI with other imaging techniques. This study compared the total cost of Gd-EOB-DTPA-MRI with multidetector computed tomography (MDCT and extracellular contrast media-enhanced MRI (ECCM-MRI as initial imaging procedures in patients with suspected hepatocellular carcinoma (HCC. We developed a decision-tree model on the basis of the Chinese clinical guidelines for HCC, which was validated by clinical experts from China. The model compared the diagnostic accuracy and costs of alternative initial imaging procedures. Compared with MDCT and ECCM-MRI, Gd-EOB-DTPA-MRI imaging was associated with higher rates of diagnostic accuracy, i.e. higher proportions of true positives (TP and true negatives (TN with lower false positives (FP. Total diagnosis and treatment cost per patient after the initial Gd-EOB-DTPA-MRI evaluation was similar to MDCT (¥30,360 vs. ¥30,803 and lower than that reported with ECCM-MRI (¥30,360 vs. ¥31,465. Lower treatment cost after initial Gd-EOB-DTPA-MRI was driven by reduced utilization of confirmatory diagnostic procedures and unnecessary treatments. The findings reported that Gd-EOB-DTPA-MRI offered higher diagnostic accuracy compared with MDCT and ECCM-MRI at a comparable cost, which indicates Gd-EOB-DTPA-MRI could be the preferred initial imaging procedure for the diagnosis of HCC in China.

  13. Leptomeningeal enhancement on preoperative brain MRI in patients with glioblastoma and its clinical impact.

    Science.gov (United States)

    Kim, Hakyoung; Lim, Do Hoon; Kim, Tae Gyu; Lee, Jung-Il; Nam, Do-Hyun; Seol, Ho Jun; Kong, Doo-Sik; Choi, Jung Won; Suh, Yeon-Lim; Kim, Sung Tae

    2018-02-23

    Leptomeningeal enhancement (LME) on preoperative brain magnetic resonance imaging (MRI) does not always indicate leptomeningeal seeding (LMS). With Stupp's regimen, authors have treated glioblastoma patients with LME on preoperative brain MRI but here we tried to find the clinical impact of LME. From 2005 to 2015, 290 patients with glioblastoma have been treated with Stupp's regimen at Samsung Medical Center. Among these, 33 patients showed LME on preoperative brain MRI. We compared the clinical outcomes between the patients with or without LME on preoperative brain MRI and analyzed the clinical results according to changes of LME at following MRI. The median survival was 23 months, and 2-year overall survival (OS) and disease-free survival (DFS) rate was 46.3% and 19.6%, respectively. Prognostic factors for OS and DFS were Karnofsky performance status, extent of resection and adjuvant chemotherapy. MGMT promoter methylation status was a significant prognostic factor for DFS. However, LME was not a significant prognostic factor for OS (P = 0.156) or DFS (P = 0.193). Among the 33 patients with LME on preoperative MRI, 21 (63.6%) showed persistent LME at the next MRI. A statistically significant difference in 2-year survival was evident between patients with and without persistent LME (OS, 17.3% and 70.1%, respectively, P = 0.044; DFS, 5.3% and 54.0%, respectively, P = 0.006). The most common pattern of failure was local recurrence. However, patients with persistent LME displayed a higher incidence of LMS than patients without LME. LME on preoperative brain MRI did not affect the clinical results in glioblastoma patients treated with the Stupp's regimen. However, persistence of LME was associated with poor survival and high possibility of LMS. For these patients, the postoperative adjuvant treatment should focus on palliative aim or more aggressive treatment scheme should be followed to overcome the disastrous results. © 2018 John Wiley & Sons Australia, Ltd.

  14. The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas

    International Nuclear Information System (INIS)

    Krestan, C.; Czerny, C.; Gstoettner, W.; Franz, P.

    2003-01-01

    The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions caused by recurrent cholesteatoma, bony defects of the facial nerve and of the labyrinth, and a defect of the tegmen tympani with a soft tissue mass in the middle ear. Postoperative MRI delineated neuritis of the facial nerve, labyrinthitis, and a meningo-encephalocele protruding into the middle ear. HRCT and MRI are excellent imaging tools to depict either bony or soft tissue complications or both if caused by acquired cholesteatomas. According to our findings and to the literature HRCT and MRI are complementary imaging methods to depict pre- or postoperative complications of acquired cholesteatomas if these are suspected by clinical examination. (orig.) [de

  15. Feasibility of an intracranial EEG-fMRI protocol at 3T: risk assessment and image quality.

    Science.gov (United States)

    Boucousis, Shannon M; Beers, Craig A; Cunningham, Cameron J B; Gaxiola-Valdez, Ismael; Pittman, Daniel J; Goodyear, Bradley G; Federico, Paolo

    2012-11-15

    Integrating intracranial EEG (iEEG) with functional MRI (iEEG-fMRI) may help elucidate mechanisms underlying the generation of seizures. However, the introduction of iEEG electrodes in the MR environment has inherent risk and data quality implications that require consideration prior to clinical use. Previous studies of subdural and depth electrodes have confirmed low risk under specific circumstances at 1.5T and 3T. However, no studies have assessed risk and image quality related to the feasibility of a full iEEG-fMRI protocol. To this end, commercially available platinum subdural grid/strip electrodes (4×5 grid or 1×8 strip) and 4 or 6-contact depth electrodes were secured to the surface of a custom-made phantom mimicking the conductivity of the human brain. Electrode displacement, temperature increase of electrodes and surrounding phantom material, and voltage fluctuations in electrode contacts were measured in a GE Discovery MR750 3T MR scanner during a variety of imaging sequences, typical of an iEEG-fMRI protocol. An electrode grid was also used to quantify the spatial extent of susceptibility artifact. The spatial extent of susceptibility artifact in the presence of an electrode was also assessed for typical imaging parameters that maximize BOLD sensitivity at 3T (TR=1500 ms; TE=30 ms; slice thickness=4mm; matrix=64×64; field-of-view=24 cm). Under standard conditions, all electrodes exhibited no measurable displacement and no clinically significant temperature increase (2.0°C) that in some cases exceeded 10°C. Induced voltages in the frequency range that could elicit neuronal stimulation (<10 kHz) were well below the threshold of 100 mV. fMRI signal intensity was significantly reduced within 20mm of the electrodes for the imaging parameters used in this study. Thus, for the conditions tested, a full iEEG-fMRI protocol poses a low risk at 3T; however, fMRI sensitivity may be reduced immediately adjacent to the electrodes. In addition, high SAR sequences

  16. Automatic delineation of brain regions on MRI and PET images from the pig

    DEFF Research Database (Denmark)

    Villadsen, Jonas; Hansen, Hanne D; Jørgensen, Louise M

    2018-01-01

    : Manual inter-modality spatial normalization to a MRI atlas is operator-dependent, time-consuming, and can be inaccurate with lack of cortical radiotracer binding or skull uptake. NEW METHOD: A parcellated PET template that allows for automatic spatial normalization to PET images of any radiotracer....... RESULTS: MRI and [11C]Cimbi-36 PET scans obtained in sixteen pigs made the basis for the atlas. The high resolution MRI scans allowed for creation of an accurately averaged MRI template. By aligning the within-subject PET scans to their MRI counterparts, an averaged PET template was created in the same...... the MRI template with individual MRI images and 0.92±0.26mm using the PET template with individual [11C]Cimbi-36 PET images. We tested the automatic procedure by assessing eleven PET radiotracers with different kinetics and spatial distributions by using perfusion-weighted images of early PET time frames...

  17. Hemorrhage detection in MRI brain images using images features

    Science.gov (United States)

    Moraru, Luminita; Moldovanu, Simona; Bibicu, Dorin; Stratulat (Visan), Mirela

    2013-11-01

    The abnormalities appear frequently on Magnetic Resonance Images (MRI) of brain in elderly patients presenting either stroke or cognitive impairment. Detection of brain hemorrhage lesions in MRI is an important but very time-consuming task. This research aims to develop a method to extract brain tissue features from T2-weighted MR images of the brain using a selection of the most valuable texture features in order to discriminate between normal and affected areas of the brain. Due to textural similarity between normal and affected areas in brain MR images these operation are very challenging. A trauma may cause microstructural changes, which are not necessarily perceptible by visual inspection, but they could be detected by using a texture analysis. The proposed analysis is developed in five steps: i) in the pre-processing step: the de-noising operation is performed using the Daubechies wavelets; ii) the original images were transformed in image features using the first order descriptors; iii) the regions of interest (ROIs) were cropped from images feature following up the axial symmetry properties with respect to the mid - sagittal plan; iv) the variation in the measurement of features was quantified using the two descriptors of the co-occurrence matrix, namely energy and homogeneity; v) finally, the meaningful of the image features is analyzed by using the t-test method. P-value has been applied to the pair of features in order to measure they efficacy.

  18. PET/MRI: Technical challenges and recent advances

    International Nuclear Information System (INIS)

    Jung, Jin Ho; Choi, Yong; Im, Ki Chun

    2016-01-01

    Integrated positron emission tomography (PET)/magnetic resonance imaging (MRI), which can provide complementary functional and anatomical information about a specific organ or body system at the molecular level, has become a powerful imaging modality to understand the molecular biology details, disease mechanisms, and pharmacokinetics in animals and humans. Although the first experiment on the PET/MRI was performed in the early 1990s, its clinical application was accomplished in recent years because there were various technical challenges in integrating PET and MRI in a single system with minimum mutual interference between PET and MRI. This paper presents the technical challenges and recent advances in combining PET and MRI along with several approaches for improving PET image quality of the PET/MRI hybrid imaging system

  19. The clinical use of contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bydder, G.M.

    1987-01-01

    Interest in the use of external agents to increase tissue contrasts has come from many sources dating back to the earliest work in NMR, to animal studies and to the widespread use of contrast agents in conventional radiological practice. The first clinical magnetic resonance images were published in 1980 and in the following year a brief account of the use of the paramagnetic agents in human volunteers was established. It was apparent relatively early in the development of magnetic resonance imaging (MRI) that a high level of soft tissue contrast was available de novo and the need for externally administered agents might therefore be small. This observation was tempered by the fact that separation of tumour from oedema was frequently better with contrast enhanced CT X-ray than with unenhanced MRI and that of a contrast agent might therefore be needed for MRI. At the end of 1983 the first parenteral agent gadoliminum diethylene triamine pentaacetic acid (Gd-DTPA) was used in volunteers and clinical studies began in 1984. At the present time only molecular O/sub 2/, oral iron compounds and Gd-DTPA are in clinical use although there are a number of other agents which have been used in animals and some of these may become available for clinical use in the foreseeable future

  20. Elemental imaging of MRI contrast agents: benchmarking of LA-ICP-MS to MRI

    Energy Technology Data Exchange (ETDEWEB)

    Pugh, J.A.T. [University of Sheffield, Centre for Analytical Sciences, Sheffield (United Kingdom); University of Sheffield, Department of Chemical and Biological Engineering, Sheffield (United Kingdom); Cox, A.G.; McLeod, C.W. [University of Sheffield, Centre for Analytical Sciences, Sheffield (United Kingdom); Bunch, J. [University of Birmingham, School of Chemistry, Birmingham (United Kingdom); Writer, M.J.; Hart, S.L. [UCL Institute of Child Health, Wolfson Centre for Gene Therapy of Childhood Disease, London (United Kingdom); Bienemann, A.; White, E. [University of Bristol, School of Clinical Sciences, Southmead Hospital, Bristol (United Kingdom); Bell, J. [Hammersmith Hospital, Metabolic and Molecular Imaging Group, MRC Clinical Sciences Centre, Imperial College London, London (United Kingdom)

    2012-06-15

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been used to map the spatial distribution of magnetic resonance imaging (MRI) contrast agents (Gd-based) in histological sections in order to explore synergies with in vivo MRI. Images from respective techniques are presented for two separate studies namely (1) convection enhanced delivery of a Gd nanocomplex (developmental therapeutic) into rat brain and (2) convection enhanced delivery, with co-infusion of Magnevist (commercial Gd contrast agent) and Carboplatin (chemotherapy drug), into pig brain. The LA technique was shown to be a powerful compliment to MRI not only in offering improved sensitivity, spatial resolution and signal quantitation but also in giving added value regarding the fate of administered agents (Gd and Pt agents). Furthermore simultaneous measurement of Fe enabled assignment of an anomalous contrast enhancement region in rat brain to haemorrhage at the infusion site. (orig.)

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... the equipment look like? How does the procedure work? How is the ... use to diagnose medical conditions. MRI uses a powerful magnetic field, radio frequency ...

  2. Review of MRI Technique and imaging findings in athletic pubalgia and the “sports hernia”

    International Nuclear Information System (INIS)

    Mullens, Frank E.; Zoga, Adam C.; Morrison, William B.; Meyers, William C.

    2012-01-01

    The clinical syndrome of athletic pubalgia has prematurely ended many promising athletic careers, has made many active, fitness conscious adults more sedentary, and has served as a diagnostic and therapeutic conundrum for innumerable trainers and physicians worldwide for decades. This diagnosis actually arises from one or more lesions within a spectrum of musculoskeletal and visceral injuries. In recent years, MRI has helped define many of these syndromes, and has proven to be both sensitive and specific for numerous potential causes of athletic pubalgia. This text will provide a comprehensive, up to date review of expected and sometimes unexpected MRI findings in the setting of athletic pubalgia, and will delineate an imaging algorithm and MRI protocol to help guide radiologists and other clinicians dealing with refractory, activity related groin pain in an otherwise young, healthy patient. There is still more to be learned about prevention and treatment plans for athletic pubalgia lesions, but accurate diagnosis should be much less nebulous and difficult with the use of MRI as a primary imaging modality.

  3. Review of MRI Technique and imaging findings in athletic pubalgia and the “sports hernia”

    Energy Technology Data Exchange (ETDEWEB)

    Mullens, Frank E. [Department of Radiology, Thomas Jefferson University, Philadelphia, PA (United States); Zoga, Adam C., E-mail: Adam.zoga@jefferson.edu [Department of Radiology, Thomas Jefferson University, Philadelphia, PA (United States); Morrison, William B. [Department of Radiology, Thomas Jefferson University, Philadelphia, PA (United States); Meyers, William C. [Chairman of Surgery, Drexel University College of Medicine, Philadelphia, PA (United States)

    2012-12-15

    The clinical syndrome of athletic pubalgia has prematurely ended many promising athletic careers, has made many active, fitness conscious adults more sedentary, and has served as a diagnostic and therapeutic conundrum for innumerable trainers and physicians worldwide for decades. This diagnosis actually arises from one or more lesions within a spectrum of musculoskeletal and visceral injuries. In recent years, MRI has helped define many of these syndromes, and has proven to be both sensitive and specific for numerous potential causes of athletic pubalgia. This text will provide a comprehensive, up to date review of expected and sometimes unexpected MRI findings in the setting of athletic pubalgia, and will delineate an imaging algorithm and MRI protocol to help guide radiologists and other clinicians dealing with refractory, activity related groin pain in an otherwise young, healthy patient. There is still more to be learned about prevention and treatment plans for athletic pubalgia lesions, but accurate diagnosis should be much less nebulous and difficult with the use of MRI as a primary imaging modality.

  4. WE-G-18C-08: Real Time Tumor Imaging Using a Novel Dynamic Keyhole MRI Reconstruction Technique

    International Nuclear Information System (INIS)

    Lee, D; Pollock, S; Whelan, B; Keall, P; Greer, P; Kim, T

    2014-01-01

    Purpose: To test the hypothesis that the novel Dynamic Keyhole MRI reconstruction technique can accelerate image acquisition whilst maintaining high image quality for lung cancer patients. Methods: 18 MRI datasets from 5 lung cancer patients were acquired using a 3T MRI scanner. These datasets were retrospectively reconstructed using (A) The novel Dynamic Keyhole technique, (B) The conventional keyhole technique and (C) the conventional zero filling technique. The dynamic keyhole technique in MRI refers to techniques in which previously acquired k-space data is used to supplement under sampled data obtained in real time. The novel Dynamic Keyhole technique utilizes a previously acquired a library of kspace datasets in conjunction with central k-space datasets acquired in realtime. A simultaneously acquired respiratory signal is utilized to sort, match and combine the two k-space streams with respect to respiratory displacement. Reconstruction performance was quantified by (1) comparing the keyhole size (which corresponds to imaging speed) required to achieve the same image quality, and (2) maintaining a constant keyhole size across the three reconstruction methods to compare the resulting image quality to the ground truth image. Results: (1) The dynamic keyhole method required a mean keyhole size which was 48% smaller than the conventional keyhole technique and 60% smaller than the zero filling technique to achieve the same image quality. This directly corresponds to faster imaging. (2) When a constant keyhole size was utilized, the Dynamic Keyhole technique resulted in the smallest difference of the tumor region compared to the ground truth. Conclusion: The dynamic keyhole is a simple and adaptable technique for clinical applications requiring real-time imaging and tumor monitoring such as MRI guided radiotherapy. Based on the results from this study, the dynamic keyhole method could increase the imaging frequency by a factor of five compared with full k

  5. CT and MRI techniques for imaging around orthopedic hardware

    Energy Technology Data Exchange (ETDEWEB)

    Do, Thuy Duong; Skornitzke, Stephan; Weber, Marc-Andre [Heidelberg Univ. (Germany). Dept. of Clinical Radiology; Sutter, Reto [Uniklinik Balgrist, Zurich (Switzerland). Radiology

    2018-01-15

    Orthopedic hardware impairs image quality in cross-sectional imaging. With an increasing number of orthopedic implants in an aging population, the need to mitigate metal artifacts in computed tomography and magnetic resonance imaging is becoming increasingly relevant. This review provides an overview of the major artifacts in CT and MRI and state-of-the-art solutions to improve image quality. All steps of image acquisition from device selection, scan preparations and parameters to image post-processing influence the magnitude of metal artifacts. Technological advances like dual-energy CT with the possibility of virtual monochromatic imaging (VMI) and new materials offer opportunities to further reduce artifacts in CT and MRI. Dedicated metal artifact reduction sequences contain algorithms to reduce artifacts and improve imaging of surrounding tissue and are essential tools in orthopedic imaging to detect postoperative complications in early stages.

  6. Imaging of posterior tibial tendon dysfunction—Comparison of high-resolution ultrasound and 3 T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Arnoldner, Michael A., E-mail: michael.arnoldner@meduniwien.ac.at [Medical University of Vienna, Vienna General Hospital, Department of Biomedical Imaging and Image-guided Therapy, Währinger Gürtel 18-20, 1090 Vienna (Austria); Gruber, Michael [Medical University of Vienna, Vienna General Hospital, Department of Biomedical Imaging and Image-guided Therapy, Währinger Gürtel 18-20, 1090 Vienna (Austria); Syré, Stefanie [Medical University of Vienna, Vienna General Hospital, Department of Trauma-Surgery, Währinger Gürtel 18-20, 1090 Vienna (Austria); Kristen, Karl-Heinz [Foot & Ankle Centre Vienna, Alser Straße 43/8, 1080 Vienna (Austria); Trnka, Hans-Jörg [Foot & Ankle Centre Vienna, Alser Straße 43/8, 1080 Vienna (Austria); Orthopaedic Hospital Vienna, Speisinger Straße 109, 1130 Vienna (Austria); Kainberger, Franz; Bodner, Gerd [Medical University of Vienna, Vienna General Hospital, Department of Biomedical Imaging and Image-guided Therapy, Währinger Gürtel 18-20, 1090 Vienna (Austria)

    2015-09-15

    Highlights: • 18 MHz high-resolution ultrasound appears to be slightly more accurate than 3 T MRI in the diagnosis of PTTD. • High-resolution ultrasound is recommended as an initial diagnostic tool. • Long-lasting PTT discomfort may require MRI. • Other pathologies can mimic PTTD. - Abstract: Purpose: Posterior tibial tendon dysfunction is the most common cause of acquired asymmetric flatfoot deformity. The purpose of this study was to determine and compare the diagnostic value of MRI and high-resolution ultrasound (HR-US) in posterior tibial tendon dysfunction (PTTD), and assess their correlation with intraoperative findings. Materials and methods: We reviewed 23 posterior tibial tendons in 23 patients with clinical findings of PTTD (13 females, 10 males; mean age, 50 years) with 18 MHz HR-US and 3 T MRI. Surgical intervention was performed in nine patients. Results: HR-US findings included 2 complete tears, 6 partial tears, 10 tendons with tendinosis, and 5 unremarkable tendons. MRI demonstrated 2 complete tears, 7 partial tears, 10 tendons with tendinosis, and 4 unremarkable tendons. HR-US and MRI were concordant in 20/23 cases (87%). Image findings for HR-US were confirmed in six of nine patients (66.7%) by intraoperative inspection, whereas imaging findings for MRI were concordant with five of nine cases (55.6%). Conclusion: Our results indicate that HR-US can be considered slightly more accurate than MRI in the detection of PTTD.

  7. Magnetic resonance imaging (MRI) of congenital cardiovascular malformations

    International Nuclear Information System (INIS)

    Sakakibara, Makoto; Kobayashi, Shirou; Imai, Hitoshi; Watanabe, Shigeru; Masuda, Yoshiaki; Inagaki, Yoshiaki; Morita, Huminori; Uematsu, Sadao; Arimizu, Noboru

    1986-01-01

    In order to determine the value of MRI in diagnosing congenital cardiovascular malformations, MR Images were obtained in 25 adult patients with congenital cardiovascular malformations. Gated MRI detected all of 13 atrial septal defects, and all of 4 ventricular septal defects, but ungated MRI detected none of 3 atrial septal defects. Other congenital cardiovascular malformations (2 with Ebstein's disease, 1 with Fallot's pentalogy, and 1 with Pulmonary stenosis) were well visualized. Vascular malformations (1 with Patent ducts arteriosus, 1 with Supravalvelar aortic stenosis, 1 with Coarctation of Aorta, 1 with Right Aortic Arch) were well visualized in all of 7 patients by ungated MRI. MRI was a valuable noninvasive method of diagnosing congenital heart disease. (author)

  8. Malignant round cell tumours of bone: atypical clinical and imaging features

    International Nuclear Information System (INIS)

    Saifuddin, A.; Whelan, J.; Pringle, J.A.S.; Cannon, S.R.

    2000-01-01

    Objective. To describe the clinical, radiological and MRI features of six atypical cases of histologically proven appendicular Ewing sarcoma/ primitive neuroectodermal tumour (PNET). Design. Retrospective review of case notes and available imaging was carried out. Patients. Six patients (4 male, 2 female; mean age 27 years, range 19-44 years), presenting over a 77-month period, were identified from the Bone Tumour Register. All had unusual clinical and imaging features for Ewing sarcoma/PNET.Results and conclusions. Four tumours were centred on the distal femoral metaphysis, one in the proximal tibial metaphysis and one in the distal tibial metaphysis. Plain radiographs were available in four cases and showed minor cortical changes. MRI demonstrated a relatively small, eccentrically located intraosseous component with a large, eccentric extraosseous component. Extension into the epiphysis was seen in three cases and into the adjacent joint in two cases. Intraosseous ''skip'' metastases were present in three cases. The clinical and imaging features were atypical for conventional intraosseous Ewing sarcoma/PNET and the exact site of origin (intraosseous, periosteal or soft-tissue) was unclear. (orig.)

  9. Defining active sacroiliitis on magnetic resonance imaging (MRI) for classification of axial spondyloarthritis: a consensual approach by the ASAS/OMERACT MRI group

    DEFF Research Database (Denmark)

    Rudwaleit, M; Jurik, A G; Hermann, K-G A

    2009-01-01

    BACKGROUND: Magnetic resonance imaging (MRI) of sacroiliac joints has evolved as the most relevant imaging modality for diagnosis and classification of early axial spondyloarthritis (SpA) including early ankylosing spondylitis. OBJECTIVES: To identify and describe MRI findings in sacroiliitis and...... relevant for sacroiliitis have been defined by consensus by a group of rheumatologists and radiologists. These definitions should help in applying correctly the imaging feature "active sacroiliitis by MRI" in the new ASAS classification criteria for axial SpA.......BACKGROUND: Magnetic resonance imaging (MRI) of sacroiliac joints has evolved as the most relevant imaging modality for diagnosis and classification of early axial spondyloarthritis (SpA) including early ankylosing spondylitis. OBJECTIVES: To identify and describe MRI findings in sacroiliitis...... conditions which may mimic SpA. Descriptions of the pathological findings and technical requirements for the appropriate acquisition were formulated. In a consensual approach MRI findings considered to be essential for sacroiliitis were defined. RESULTS: Active inflammatory lesions such as bone marrow oedema...

  10. Assessing the Accuracy and Reliability of Root Crack and Fracture Detection in Teeth Using Sweep Imaging with Fourier Transform (SWIFT) Magnetic Resonance Imaging (MRI)

    Science.gov (United States)

    Schuurmans, Tyler J.

    Introduction: Magnetic Resonance Imaging (MRI) has the potential to aid in determining the presence and extent of cracks/fractures in teeth due to more advantageous contrast, without ionizing radiation. An MRI technique called Sweep Imaging with Fourier Transform (SWIFT) has overcome many of the inherent difficulties of conventional MRI with detecting fast-relaxing signals from densely mineralized dental tissues. The objectives of this in vitro investigation were to develop MRI criteria for root crack/fracture identification in teeth and to establish intra- and inter-rater reliabilities and corresponding sensitivity and specificity values for the detection of tooth-root cracks/fractures in SWIFT MRI and limited field of view (FOV) CBCT. Materials and Methods: MRI-based criteria for crack/fracture appearance was developed by an MRI physicist and 6 dentists, including 3 endodontists and 1 Oral and Maxillofacial (OMF) radiologist. Twenty-nine human adult teeth previously extracted following clinical diagnosis by a board-certified endodontist of a root crack/fracture were frequency-matched to 29 non-cracked controls. Crack/fracture status confirmation was performed with magnified visual inspection, transillumination and vital staining. Samples were scanned with two 3D imaging modalities: 1) SWIFT MRI (10 teeth/scan) via a custom oral radiofrequency (RF) coil and a 90cm, 4-T magnet; 2) Limited FOV CBCT (1 tooth/scan) via a Carestream (CS) 9000 (Rochester, NY). Following a training period, a blinded 4-member panel (3 endodontists, 1 OMF radiologist) evaluated the images with a proportion randomly re-tested to establish intra-rater reliability. Overall observer agreement was measured using Cohen's kappa and levels of agreement judged using the criteria of Landis and Koch. Sensitivity and specificity were computed with 95% confidence interval (CI); statistical significance was set at alpha ≤ 0.05. Results: MRI-based crack/fracture criteria were defined as 1-2 sharply

  11. Quantitative magnetic resonance imaging (MRI) evaluation of cartilage repair after microfracture (MF) treatment for adult unstable osteochondritis dissecans (OCD) in the ankle: correlations with clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Hongyue; Lu, Rong; Feng, Xiaoyuan; Chen, Shuang [Fudan University, Department of Radiology, Huashan Hospital, Shanghai (China); Shang, Xiliang; Li, Hong; Hua, Yinghui [Fudan University, Department of Sports Medicine, Huashan Hospital, Shanghai (China)

    2014-08-15

    To quantitatively evaluate cartilage repair after microfracture (MF) for ankle osteochondritis dissecans (OCD) using MRI and analyse correlations between MRI and clinical outcome. Forty-eight patients were recruited and underwent MR imaging, including 3D-DESS, T2-mapping and T2-STIR sequences, and completed American Orthopaedic Foot and Ankle Society (AOFAS) scoring. Thickness index, T2 index of repair tissue (RT) and volume of subchondral bone marrow oedema (BME) were calculated. Subjects were divided into two groups: group A (3-12 months post-op), and group B (12-24 months post-op). Student's t test was used to compare the MRI and AOFAS score between two groups and Pearson's correlation coefficient to analyse correlations between them. Thickness index and AOFAS score of group B were higher than group A (P < 0.001, P < 0.001). T2 index and BME of group B were lower than group A (P < 0.001, P = 0.012). Thickness index, T2 index and BME were all correlated with AOFAS score (r = 0.416, r = -0.475, r = -0.353), but BME was correlated with neither thickness index nor T2 index. Significant improvement from MF can be expected on the basis of the outcomes of quantitative MRI and AOFAS score. MRI was correlated with AOFAS score. BME is insufficient as an independent predictor to evaluate repair quality, but reduction of BME can improve the patient's clinical outcome. (orig.)

  12. Quantitative magnetic resonance imaging (MRI) evaluation of cartilage repair after microfracture (MF) treatment for adult unstable osteochondritis dissecans (OCD) in the ankle: correlations with clinical outcome

    International Nuclear Information System (INIS)

    Tao, Hongyue; Lu, Rong; Feng, Xiaoyuan; Chen, Shuang; Shang, Xiliang; Li, Hong; Hua, Yinghui

    2014-01-01

    To quantitatively evaluate cartilage repair after microfracture (MF) for ankle osteochondritis dissecans (OCD) using MRI and analyse correlations between MRI and clinical outcome. Forty-eight patients were recruited and underwent MR imaging, including 3D-DESS, T2-mapping and T2-STIR sequences, and completed American Orthopaedic Foot and Ankle Society (AOFAS) scoring. Thickness index, T2 index of repair tissue (RT) and volume of subchondral bone marrow oedema (BME) were calculated. Subjects were divided into two groups: group A (3-12 months post-op), and group B (12-24 months post-op). Student's t test was used to compare the MRI and AOFAS score between two groups and Pearson's correlation coefficient to analyse correlations between them. Thickness index and AOFAS score of group B were higher than group A (P < 0.001, P < 0.001). T2 index and BME of group B were lower than group A (P < 0.001, P = 0.012). Thickness index, T2 index and BME were all correlated with AOFAS score (r = 0.416, r = -0.475, r = -0.353), but BME was correlated with neither thickness index nor T2 index. Significant improvement from MF can be expected on the basis of the outcomes of quantitative MRI and AOFAS score. MRI was correlated with AOFAS score. BME is insufficient as an independent predictor to evaluate repair quality, but reduction of BME can improve the patient's clinical outcome. (orig.)

  13. Functional brain imaging in the clinical assessment of consciousness.

    Directory of Open Access Journals (Sweden)

    Michael S Rafii

    2010-11-01

    Full Text Available Recent findings suggest that functional brain imaging might be used to identify consciousness in patients diagnosed with persistent vegetative state and minimally conscious state. Michael Rafii and James Brewer discuss the potential for fMRI's wider implementation in clinical practice, and associated caveats.

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... types of clips used for brain aneurysms some types of metal coils placed within blood vessels nearly all cardiac defibrillators and pacemakers You ... called MR angiography (MRA) provides detailed images of blood vessels in the ... the opening of certain types of MRI machines. The presence of an implant ...

  15. Progress in clinical research and application of resting state functional brain imaging

    International Nuclear Information System (INIS)

    Long Miaomiao; Ni Hongyan

    2013-01-01

    Resting state functional brain imaging experimental design is free of stimulus task and offers various parametric maps through different data-driven post processing methods with endogenous BOLD signal changes as the source of imaging. Mechanism of resting state brain activities could be extensively studied with improved patient compliance and clinical application compared with task related functional brain imaging. Also resting state functional brain imaging can be used as a method of data acquisition, with implicit neuronal activity as a kind of experimental design, to reveal characteristic brain activities of epileptic patient. Even resting state functional brain imaging data processing method can be used to analyze task related functional MRI data, opening new horizons of task related functional MRI study. (authors)

  16. Osseous metastases of chordoma: imaging and clinical findings

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie; Torriani, Martin; Bredella, Miriam [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Chebib, Ivan [Massachusetts General Hospital, Department of Pathology, Boston, MA (United States)

    2017-03-15

    To describe the imaging and clinical characteristics of chordoma osseous metastases (COM). Our study was IRB approved and HIPAA compliant. A retrospective search of our pathology database for pathology-proven COM yielded 15 patients who had undergone MRI, CT, bone scan, and/or FDG-PET/CT. The imaging and clinical features of the COMs were recorded. A control group of age and gender matched chordoma patients without osseous metastasis was evaluated. The COM mean maximal dimension was 6.4 ± 4.0 cm. The majority (60%) of patients had one lesion. Extra-osseous soft tissue component was present in 85% and was larger than intra-osseous component in 76%. On MRI the lesions were heterogeneous but predominantly T2 hyperintense with hypointense septae, and with variable enhancement. On CT the lesions were typically destructive or permeative; calcifications were rare. The extent of the soft tissue component was isodense to muscle on CT and therefore better evaluated on MRI. COM was in a body part contiguous to the site of the primary tumor. Compared to the controls, COM patients were more likely to have local recurrence (P = 0.0009) and positive resection margins (P = 0.002). At 1 year, 33% of COM patients were deceased and 13% had progressive metastases. COM are associated with large extra-osseous soft tissue components, which are better visualized by MRI. They are often located in a body part contiguous to the site of the primary tumor, portend poor prognosis, and are associated with positive resection margins and local recurrence. (orig.)

  17. Simultaneous PET/MRI with 13C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification

    DEFF Research Database (Denmark)

    Hansen, Adam E.; Andersen, Flemming L.; Henriksen, Sarah T.

    2016-01-01

    Background: Integrated PET/MRI with hyperpolarized 13C magnetic resonance spectroscopic imaging (13C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented...... for a clinical whole-body system using simultaneous 1 H-MRI and PET but never for 13C-MRSI and PET. Here, the feasibility of simultaneous PET and 13C-MRSI as well as hyperpolarized 13C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. Methods: Combined PET and 13C......-MRSI phantoms including a NEMA [18F]-FDG phantom, 13C-acetate and 13C-urea sources, and hyperpolarized 13C-pyruvate were imaged repeatedly with PET and/or 13C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET...

  18. Value of retrospective image fusion of 18F-FDG PET and MRI for preoperative staging of head and neck cancer: Comparison with PET/CT and contrast-enhanced neck MRI

    International Nuclear Information System (INIS)

    Kanda, Tomonori; Kitajima, Kazuhiro; Suenaga, Yuko; Konishi, Jyunya; Sasaki, Ryohei; Morimoto, Koichi; Saito, Miki; Otsuki, Naoki; Nibu, Ken-ichi; Sugimura, Kazuro

    2013-01-01

    Purpose: To assess the clinical value of retrospective image fusion of neck MRI and 18 F-fluorodeoxyglucose ( 18 F-FDG) PET for locoregional extension and nodal staging of neck cancer. Materials and methods: Thirty patients with carcinoma of the oral cavity or hypopharynx underwent PET/CT and contrast-enhanced neck MRI for initial staging before surgery including primary tumor resection and neck dissection. Diagnostic performance of PET/CT, MRI, and retrospective image fusion of PET and MRI (fused PET/MRI) for assessment of the extent of the primary tumor (T stage) and metastasis to regional lymph nodes (N stage) was evaluated. Results: Accuracy for T status was 87% for fused PET/MRI and 90% for MRI, thus proving significantly superior to PET/CT, which had an accuracy of 67% (p = 0.041 and p = 0.023, respectively). Accuracy for N status was 77% for both fused PET/MRI and PET/CT, being superior to MRI, which had an accuracy of 63%, although the difference was not significant (p = 0.13). On a per-level basis, the sensitivity, specificity and accuracy for detection of nodal metastasis were 77%, 96% and 93% for both fused PET/MRI and PET/CT, compared with 49%, 99% and 91% for MRI, respectively. The differences for sensitivity (p = 0.0026) and accuracy (p = 0.041) were significant. Conclusion: Fused PET/MRI combining the individual advantages of MRI and PET is a valuable technique for assessment of staging neck cancer

  19. MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI

    Science.gov (United States)

    Chun, Se Young; Reese, Timothy G.; Ouyang, Jinsong; Guerin, Bastien; Catana, Ciprian; Zhu, Xuping; Alpert, Nathaniel M.; El Fakhri, Georges

    2014-01-01

    Respiratory and cardiac motion is the most serious limitation to whole-body PET, resulting in spatial resolution close to 1 cm. Furthermore, motion-induced inconsistencies in the attenuation measurements often lead to significant artifacts in the reconstructed images. Gating can remove motion artifacts at the cost of increased noise. This paper presents an approach to respiratory motion correction using simultaneous PET/MRI to demonstrate initial results in phantoms, rabbits, and nonhuman primates and discusses the prospects for clinical application. Methods Studies with a deformable phantom, a free-breathing primate, and rabbits implanted with radioactive beads were performed with simultaneous PET/MRI. Motion fields were estimated from concurrently acquired tagged MR images using 2 B-spline nonrigid image registration methods and incorporated into a PET list-mode ordered-subsets expectation maximization algorithm. Using the measured motion fields to transform both the emission data and the attenuation data, we could use all the coincidence data to reconstruct any phase of the respiratory cycle. We compared the resulting SNR and the channelized Hotelling observer (CHO) detection signal-to-noise ratio (SNR) in the motion-corrected reconstruction with the results obtained from standard gating and uncorrected studies. Results Motion correction virtually eliminated motion blur without reducing SNR, yielding images with SNR comparable to those obtained by gating with 5–8 times longer acquisitions in all studies. The CHO study in dynamic phantoms demonstrated a significant improvement (166%–276%) in lesion detection SNR with MRI-based motion correction as compared with gating (P < 0.001). This improvement was 43%–92% for large motion compared with lesion detection without motion correction (P < 0.001). CHO SNR in the rabbit studies confirmed these results. Conclusion Tagged MRI motion correction in simultaneous PET/MRI significantly improves lesion detection

  20. Clinical use of MRI for the evaluation of acute appendicitis during pregnancy.

    Science.gov (United States)

    Patel, Darshan; Fingard, Jordan; Winters, Sean; Low, Gavin

    2017-07-01

    The purpose of this study was to determine the diagnostic accuracy of MRI for detecting acute appendicitis in pregnancy in a multi-institution study involving general body MR readers with no specific expertise in MR imaging of the pregnant patient. Retrospective review of MRI examinations on PACS in 42 pregnant patients was evaluated for acute right lower quadrant pain. Three fellowship-trained general body radiologists analyzed the MRI examinations in consensus and attempted to localize the appendix, assess for features of appendicitis, and exclude alternative etiologies for the right lower quadrant pain. Of the 42 MRI examinations, the readers noted 6 cases of acute appendicitis, 16 cases of a normal appendix, and 20 cases involving non-visualization of the appendix but where there were no secondary features of acute appendicitis. Based on the surgical data and clinical follow-up, there were 3 true-positive cases, 3 false-positive cases, 34 true-negative cases, and 2 false-negative cases of acute appendicitis on MRI. This yielded an accuracy of 88.1%, sensitivity of 60%, specificity of 91.9%, positive predictive value of 50%, and negative predictive value of 94.4% for the detection of acute appendicitis in the pregnant patient on MRI. Alternative etiologies for the right lower quadrant pain on MRI included torsion of an ovarian dermoid in 1 case and pyelonephritis in 1 case. MRI is an excellent modality for excluding acute appendicitis in pregnant patients presenting with right lower quadrant pain.

  1. Image fusion between whole body FDG PET images and whole body MRI images using a full-automatic mutual information-based multimodality image registration software

    International Nuclear Information System (INIS)

    Uchida, Yoshitaka; Nakano, Yoshitada; Fujibuchi, Toshiou; Isobe, Tomoko; Kazama, Toshiki; Ito, Hisao

    2006-01-01

    We attempted image fusion between whole body PET and whole body MRI of thirty patients using a full-automatic mutual information (MI) -based multimodality image registration software and evaluated accuracy of this method and impact of the coregistrated imaging on diagnostic accuracy. For 25 of 30 fused images in body area, translating gaps were within 6 mm in all axes and rotating gaps were within 2 degrees around all axes. In head and neck area, considerably much gaps caused by difference of head inclination at imaging occurred in 16 patients, however these gaps were able to decrease by fused separately. In 6 patients, diagnostic accuracy using PET/MRI fused images was superior compared by PET image alone. This work shows that whole body FDG PET images and whole body MRI images can be automatically fused using MI-based multimodality image registration software accurately and this technique can add useful information when evaluating FDG PET images. (author)

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head (particularly the brain) in routine clinical practice. top of page What are some common uses ... gadolinium contrast material except when absolutely necessary for medical treatment. See the MRI Safety page for more ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head (particularly the brain) in routine clinical practice. top of page What are some common uses ... may follow your regular daily routine and take food and medications as usual. Some MRI examinations may ...

  4. Making the most of the imaging we have: using head MRI to estimate body composition

    International Nuclear Information System (INIS)

    Lack, C.M.; Lesser, G.J.; Umesi, U.N.; Bowns, J.; Chen, M.Y.; Case, D.; Hightower, R.C.; Johnson, A.J.

    2016-01-01

    Aim: To investigate the use of clinical head magnetic resonance imaging (MRI) in determining body composition and to evaluate how well it correlates with established measures based on abdominal computed tomography (CT). Materials and methods: Ninety-nine consecutive patients were identified who had undergone both brain MRI and abdominal CT within a 2-week span. Volumes of fat and muscle in the extracranial head were measured utilising several techniques by both abdominal CT and head MRI. Results: MRI-based total fat volumes in the head correlated with CT-based measurements of fat in the abdomen using both single-section (r=0.64, p<0.01) and multisection (r=0.60, p<0.01) techniques. No significant correlation was found between muscle volumes in the abdomen and head. Conclusion: Based on the present results, head MRI-based measures may provide a useful surrogate for CT measurements of abdominal fat, particularly in patients with neurological cancers, as head MRI (and not abdominal CT) is routinely and repeatedly obtained for the purpose of clinical care for these patients. - Highlights: • We compared body composition using brain MRI with previously proven abdominal CT. • Fat and muscle volumes of the extracranial compartment can be measured by MRI. • Muscle volume in the face does not correlate with abdominal muscle volume. • Fat volume in the face can be used as a surrogate for abdominal fat volume.

  5. Imaging children suffering from lymphoma: an evaluation of different {sup 18}F-FDG PET/MRI protocols compared to whole-body DW-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kirchner, Julian; Buchbender, Christian; Antoch, Gerald [University Dusseldorf, Department of Diagnostic and Interventional Radiology, Medical Faculty, Dusseldorf (Germany); Deuschl, Cornelius; Schweiger, Bernd; Forsting, Michael; Umutlu, Lale [University Hospital Essen, University of Duisburg-Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Herrmann, Ken [University Hospital Essen, University of Duisburg-Essen, Department of Nuclear Medicine, Essen (Germany)

    2017-09-15

    The objectives of this study were to evaluate and compare the diagnostic potential of different PET/MRI reading protocols, entailing non-enhanced / contrast-enhanced and diffusion-weighted {sup 18}F-FDG PET/MR imaging and whole-body diffusion-weighted MRI for lesion detection and determination of the tumor stage in pediatric lymphoma patients. A total of 28 {sup 18}F-FDG PET/MRI datasets were included for analysis of four different reading protocols: (1) PET/MRI utilizing sole unenhanced T2w and T1w imaging, (2) PET/MRI utilizing additional contrast enhanced sequences, (3) PET/MR imaging utilizing unenhanced, contrast enhanced and DW imaging or (4) WB-DW-MRI. Statistical analyses were performed on a per-patient and a per-lesion basis. Follow-up and prior examinations as well as histopathology served as reference standards. PET/MRI correctly identified all 17 examinations with active lymphoma disease, while WB-DW-MRI correctly identified 15/17 examinations. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy were 96%, 96.5%, 97%, 95%, and 96% for PET/MRI{sub 1}; 97%, 96.5%, 97%, 96.5%, and 97% for PET/MRI{sub 2}; 97%, 96.5%, 97%, 96.5%, and 97% for PET/MRI{sub 3} and 77%, 96%, 96%, 78.5% and 86% for MRI-DWI. {sup 18}F-FDG PET/MRI is superior to WB-DW-MRI in staging pediatric lymphoma patients. Neither application of contrast media nor DWI leads to a noticeable improvement of the diagnostic accuracy of PET/MRI. Thus, unenhanced PET/MRI may play a crucial role for the diagnostic work-up of pediatric lymphoma patients in the future. (orig.)

  6. An Observational Study to Assess Brain MRI Change and Disease Progression in Multiple Sclerosis Clinical Practice-The MS-MRIUS Study.

    Science.gov (United States)

    Zivadinov, Robert; Khan, Nasreen; Medin, Jennie; Christoffersen, Pia; Price, Jennifer; Korn, Jonathan R; Bonzani, Ian; Dwyer, Michael G; Bergsland, Niels; Carl, Ellen; Silva, Diego; Weinstock-Guttman, Bianca

    2017-05-01

    To describe methodology, interim baseline, and longitudinal magnetic resonance imaging (MRI) acquisition parameter characteristics of the multiple sclerosis clinical outcome and MRI in the United States (MS-MRIUS). The MS-MRIUS is an ongoing longitudinal and retrospective study of MS patients on fingolimod. Clinical and brain MRI image scan data were collected from 600 patients across 33 MS centers in the United States. MRI brain outcomes included change in whole-brain volume, lateral ventricle volume, T2- and T1-lesion volumes, and new/enlarging T2 and gadolinium-enhancing lesions. Interim baseline and longitudinal MRI acquisition parameters results are presented for 252 patients. Mean age was 44 years and 81% were female. Forty percent of scans had 3-dimensional (3D) T1 sequence in the preindex period, increasing to 50% in the postindex period. Use of 2-dimensional (2D) T1 sequence decreased over time from 85% in the preindex period to 65% in the postindex. About 95% of the scans with FLAIR and 2D T1-WI were considered acceptable or good quality compared to 99-100% with 3D T1-WI. There were notable changes in MRI hardware, software, and coil (39.5% in preindex to index and 50% in index to postindex). MRI sequence parameters (orientation, thickness, or protocol) differed for 36%, 29%, and 20% of index/postindex scans for FLAIR, 2D T1-WI, and 3D T1-WI, respectively. The MS-MRIUS study linked the clinical and brain MRI outcomes into an integrated database to create a cohort of fingolimod patients in real-world practice. Variability was observed in MRI acquisition protocols overtime. © 2016 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  7. Testing the quality of images for permanent magnet desktop MRI systems using specially designed phantoms.

    Science.gov (United States)

    Qiu, Jianfeng; Wang, Guozhu; Min, Jiao; Wang, Xiaoyan; Wang, Pengcheng

    2013-12-21

    Our aim was to measure the performance of desktop magnetic resonance imaging (MRI) systems using specially designed phantoms, by testing imaging parameters and analysing the imaging quality. We designed multifunction phantoms with diameters of 18 and 60 mm for desktop MRI scanners in accordance with the American Association of Physicists in Medicine (AAPM) report no. 28. We scanned the phantoms with three permanent magnet 0.5 T desktop MRI systems, measured the MRI image parameters, and analysed imaging quality by comparing the data with the AAPM criteria and Chinese national standards. Image parameters included: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, signal-to-noise ratio (SNR), and image uniformity. The image parameters of three desktop MRI machines could be measured using our specially designed phantoms, and most parameters were in line with MRI quality control criterion, including: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, image uniformity and slice position accuracy. However, SNR was significantly lower than in some references. The imaging test and quality control are necessary for desktop MRI systems, and should be performed with the applicable phantom and corresponding standards.

  8. Testing the quality of images for permanent magnet desktop MRI systems using specially designed phantoms

    International Nuclear Information System (INIS)

    Qiu, Jianfeng; Wang, Guozhu; Min, Jiao; Wang, Xiaoyan; Wang, Pengcheng

    2013-01-01

    Our aim was to measure the performance of desktop magnetic resonance imaging (MRI) systems using specially designed phantoms, by testing imaging parameters and analysing the imaging quality. We designed multifunction phantoms with diameters of 18 and 60 mm for desktop MRI scanners in accordance with the American Association of Physicists in Medicine (AAPM) report no. 28. We scanned the phantoms with three permanent magnet 0.5 T desktop MRI systems, measured the MRI image parameters, and analysed imaging quality by comparing the data with the AAPM criteria and Chinese national standards. Image parameters included: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, signal-to-noise ratio (SNR), and image uniformity. The image parameters of three desktop MRI machines could be measured using our specially designed phantoms, and most parameters were in line with MRI quality control criterion, including: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, image uniformity and slice position accuracy. However, SNR was significantly lower than in some references. The imaging test and quality control are necessary for desktop MRI systems, and should be performed with the applicable phantom and corresponding standards. (paper)

  9. Role of magnetic resonance imaging (MRI), MR spectroscopy (MRS) and other imaging modalities in breast cancer

    International Nuclear Information System (INIS)

    Sharma, Uma; Virendra Kumar; Jagannathan, N.R.

    2004-01-01

    Breast cancer is the commonest cancer among women world over and the diagnosis continues to generate fear and turmoil in the life of patients and their families. This article describes the currently available techniques used for screening primary and recurrent breast cancers and the evaluation of therapeutic response of breast cancer with special emphasis on MRI and MRS techniques. MRI, a noninvasive technique, provides anatomic images in multiple planes enabling tissue characterization. Contrast enhanced MR studies have been found to be useful in the diagnosis of small tumors in dense breast benign diseases from malignant ones. In vivo magnetic resonance spectroscopy (MRS) is another useful technique for diagnosis and for assessing the biochemical status of normal and diseased tissues. Being noninvasive, MR techniques can be used repetitively for assessment of response of the tumor to various therapeutic regimens and for evaluating the efficacy of drugs at both the structural and molecular level. An overview of the various aspects of different imaging modalities used in breast cancer research including various in vivo MR methodologies with clinical examples is presented in this review. (author)

  10. Imaging of abdominal tumours: CT or MRI?

    International Nuclear Information System (INIS)

    Olsen, Oeystein E.

    2009-01-01

    The scope of this review is to discuss a theoretical approach to imaging policy, particularly in the perspective of radiation risk reduction. Decisions are ideally driven by empirical evidence about efficacy and risk, e.g., in classical hierarchical efficacy model. As a result of the paucity of empirical evidence (inevitable because of rapid technological development), a pragmatic model is needed. This should avoid overemphasis of factors that currently seem to hamper change, namely personal preference, local expertise, infrastructure, availability. Extrapolation of current general knowledge about CT and MRI demonstrates how a pragmatic approach can be applied in the real world with intermediate goals such as (1) channeling patients from CT to MRI, and (2) reducing CT-delivered radiation. Increased utilisation of MRI in body imaging requires optimisation of scan protocols and equipment, and, being a very operator-dependent modality, the active involvement of the radiologist. In CT dose reduction the main challenge is to benchmark the minimum radiation-dose requirement, and therefore the minimum required image quality that is diagnostically acceptable. As this will ultimately depend on pre-test likelihoods in institutional populations, it is difficult to issue general guidance, and local assessment remains a cornerstone in this effort. (orig.)

  11. Functional MRI of the patellofemoral joint: comparison of ultrafast MRI, motion-triggered cine MRI and static MRI

    Energy Technology Data Exchange (ETDEWEB)

    Muhle, C. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Brossmann, J. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Melchert, U.H. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Schroeder, C. [Radiologische Abt., Universitaets-Kinderklinik, Christian-Albrechts-Universitaet, Kiel (Germany); Boer, R. de [Philips Medical Systems, Best (Netherlands); Spielmann, R.P. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Heller, M. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany)

    1995-12-31

    To evaluate the feasibility and usefulness of ultrafast MRI (u), patellar tracking from 30 of flexion to knee extension (0 ) was analysed and compared with motion-triggered cine MRI (m) and a static MRI technique (s). The different imaging methods were compared in respect of the patellofemoral relationship, the examination time and image quality. Eight healthy subjects and four patients (in total 18 joints) with patellar subluxation or luxation were examined. Significant differences between the static MRI series without quadriceps contraction and the functional MRI studies (motion-triggered cine MRI and ultrafast MRI) were found for the patellar tilt angle. In the dynamic joint studies there was no statistical difference of the regression coefficients between the motion-triggered cine MRI studies and the ultrafast MRI studies. The findings of the functional MRI studies compared with the static MRI images were significantly different for the lateralisation of the patella, expressed by the lateral patellar displacement and bisect offset. No significant differences in patellar lateralisation were found between motion-triggered cine MRI and ultrafast MRI. Ultrafast MRI was superior to motion-triggered cine MRI in terms of the reduction in imaging time and improvement of the image quality. (orig.)

  12. Functional MRI of the patellofemoral joint: comparison of ultrafast MRI, motion-triggered cine MRI and static MRI

    International Nuclear Information System (INIS)

    Muhle, C.; Brossmann, J.; Melchert, U.H.; Schroeder, C.; Boer, R. de; Spielmann, R.P.; Heller, M.

    1995-01-01

    To evaluate the feasibility and usefulness of ultrafast MRI (u), patellar tracking from 30 of flexion to knee extension (0 ) was analysed and compared with motion-triggered cine MRI (m) and a static MRI technique (s). The different imaging methods were compared in respect of the patellofemoral relationship, the examination time and image quality. Eight healthy subjects and four patients (in total 18 joints) with patellar subluxation or luxation were examined. Significant differences between the static MRI series without quadriceps contraction and the functional MRI studies (motion-triggered cine MRI and ultrafast MRI) were found for the patellar tilt angle. In the dynamic joint studies there was no statistical difference of the regression coefficients between the motion-triggered cine MRI studies and the ultrafast MRI studies. The findings of the functional MRI studies compared with the static MRI images were significantly different for the lateralisation of the patella, expressed by the lateral patellar displacement and bisect offset. No significant differences in patellar lateralisation were found between motion-triggered cine MRI and ultrafast MRI. Ultrafast MRI was superior to motion-triggered cine MRI in terms of the reduction in imaging time and improvement of the image quality. (orig.)

  13. Comparison between target magnetic resonance imaging (MRI) in-gantry and cognitively directed transperineal or transrectal-guided prostate biopsies for Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 MRI lesions.

    Science.gov (United States)

    Yaxley, Anna J; Yaxley, John W; Thangasamy, Isaac A; Ballard, Emma; Pokorny, Morgan R

    2017-11-01

    To compare the detection rates of prostate cancer (PCa) in men with Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 abnormalities on 3-Tesla multiparametric (mp) magnetic resonance imaging (MRI) using in-bore MRI-guided biopsy compared with cognitively directed transperineal (cTP) biopsy and transrectal ultrasonography (cTRUS) biopsy. This was a retrospective single-centre study of consecutive men attending the private practice clinic of an experienced urologist performing MRI-guided biopsy and an experienced urologist performing cTP and cTRUS biopsy techniques for PI-RADS 3-5 lesions identified on 3-Tesla mpMRI. There were 595 target mpMRI lesions from 482 men with PI-RADS 3-5 regions of interest during 483 episodes of biopsy. The abnormal mpMRI target lesion was biopsied using the MRI-guided method for 298 biopsies, the cTP method for 248 biopsies and the cTRUS method for 49 biopsies. There were no significant differences in PCa detection among the three biopsy methods in PI-RADS 3 (48.9%, 40.0% and 44.4%, respectively), PI-RADS 4 (73.2%, 81.0% and 85.0%, respectively) or PI-RADS 5 (95.2, 92.0% and 95.0%, respectively) lesions, and there was no significant difference in detection of significant PCa among the biopsy methods in PI-RADS 3 (42.2%, 30.0% and 33.3%, respectively), PI-RADS 4 (66.8%, 66.0% and 80.0%, respectively) or PI-RADS 5 (90.5%, 89.8% and 90.0%, respectively) lesions. There were also no differences in PCa or significant PCa detection based on lesion location or size among the methods. We found no significant difference in the ability to detect PCa or significant PCa using targeted MRI-guided, cTP or cTRUS biopsy methods. Identification of an abnormal area on mpMRI appears to be more important in increasing the detection of PCa than the technique used to biopsy an MRI abnormality. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  14. Utility of positron emission tomography-magnetic resonance imaging in musculoskeletal imaging

    Institute of Scientific and Technical Information of China (English)

    Ammar A Chaudhry; Maryam Gul; Elaine Gould; Mathew Teng; Kevin Baker; Robert Matthews

    2016-01-01

    Differentiation between neoplastic and nonneoplastic conditions magnetic resonance imaging(MRI) has established itself as one of the key clinical tools in evaluation of musculoskeletal pathology. However, MRI still has several key limitations which require supplemental information from additional modalities to complete evaluation of various disorders. This has led to the development hybrid positron emission tomography(PET)-MRI which is rapidly evolving to address key clinical questions by using the morphological strengths of MRI and functional information of PET imaging. In this article, we aim to review physical principles and techniques of PET-MRI and discuss clinical utility of functional information obtained from PET imaging and structural information obtained from MRI imaging for the evaluation of musculoskeletal pathology. More specifically, this review highlights the role of PET-MRI in musculoskeletal oncology including initial diagnosis and staging, treatment planning and posttreatment follow-up. Also we will review utility of PET-MRI in evaluating musculoskeletal infections(especially in the immunocompromised and diabetics) and inflammatory condition. Additionally, common pitfalls of PET-MRI will be addressed.

  15. MRI-based diagnostic imaging of the intratemporal facial nerve

    International Nuclear Information System (INIS)

    Kress, B.; Baehren, W.

    2001-01-01

    Detailed imaging of the five sections of the full intratemporal course of the facial nerve can be achieved by MRI and using thin tomographic section techniques and surface coils. Contrast media are required for tomographic imaging of pathological processes. Established methods are available for diagnostic evaluation of cerebellopontine angle tumors and chronic Bell's palsy, as well as hemifacial spasms. A method still under discussion is MRI for diagnostic evaluation of Bell's palsy in the presence of fractures of the petrous bone, when blood volumes in the petrous bone make evaluation even more difficult. MRI-based diagnostic evaluation of the idiopatic facial paralysis currently is subject to change. Its usual application cannot be recommended for routine evaluation at present. However, a quantitative analysis of contrast medium uptake of the nerve may be an approach to improve the prognostic value of MRI in acute phases of Bell's palsy. (orig./CB) [de

  16. MRI in dementia-type diseases

    International Nuclear Information System (INIS)

    Bodea, S.V.; Muehl-Benninghaus, R.

    2015-01-01

    Dementia-inducing conditions represent a leading cause of disability and are a major health concern in industrialized countries. The burden these conditions put on society is certain to rise in the context of an ever-increasing elderly population. As these conditions feature an insidious onset and overlapping clinical features, imaging is a powerful tool in refining the diagnosis and assessing the progression of dementing conditions. The radiologist needs to be aware of and be able to detect underlying pathologies which could be reversible. Furthermore, imaging is important not only in excluding other pathologies but also in improving diagnostic accuracy. This article presents the typical clinical presentations as well as magnetic resonance imaging (MRI) features of the degenerative and the non-degenerative causes of dementia. The focus is on the core knowledge for MRI diagnostics in dementing conditions and a brief presentation of the latest MRI techniques which may become a part of standard imaging protocols in the future. (orig.) [de

  17. Time consumption and quality of an automated fusion tool for SPECT and MRI images of the brain

    International Nuclear Information System (INIS)

    Fiedler, E.; Platsch, G.; Schwarz, A.; Schmiedehausen, K.; Kuwert, T.; Tomandl, B.; Huk, W.; Rupprecht, Th.; Rahn, N.

    2003-01-01

    Aim: Although the fusion of images from different modalities may improve diagnostic accuracy, it is rarely used in clinical routine work due to logistic problems. Therefore we evaluated performance and time needed for fusing MRI and SPECT images using a semiautomated dedicated software. Patients, material and method: In 32 patients regional cerebral blood flow was measured using 99m Tc ethylcystein dimer (ECD) and the three-headed SPECT camera MultiSPECT 3. MRI scans of the brain were performed using either a 0,2 T Open or a 1,5 T Sonata. Twelve of the MRI data sets were acquired using a 3 D-T1 w MPRAGE sequence, 20 with a 2D acquisition technique and different echo sequences. Image fusion was performed on a Syngo workstation using an entropy minimizing algorithm by an experienced user of the software. The fusion results were classified. We measured the time needed for the automated fusion procedure and in case of need that for manual realignment after automated, but insufficient fusion. Results: The mean time of the automated fusion procedure was 123 s. It was for the 2D significantly shorter than for the 3D MRI datasets. For four of the 2D data sets and two of the 3D data sets an optimal fit was reached using the automated approach. The remaining 26 data sets required manual correction. The sum of the time required for automated fusion and that needed for manual correction averaged 320 s (50-886 s). Conclusion: The fusion of 3D MRI data sets lasted significantly longer than that of the 2D MRI data. The automated fusion tool delivered in 20% an optimal fit, in 80% manual correction was necessary. Nevertheless, each of the 32 SPECT data sets could be merged in less than 15 min with the corresponding MRI data, which seems acceptable for clinical routine use. (orig.) [de

  18. Value of retrospective image fusion of {sup 18}F-FDG PET and MRI for preoperative staging of head and neck cancer: Comparison with PET/CT and contrast-enhanced neck MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kanda, Tomonori [Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Department of Radiology, Hyogo Cancer Center, Hyogo (Japan); Kitajima, Kazuhiro, E-mail: kitajima@med.kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Suenaga, Yuko; Konishi, Jyunya [Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Sasaki, Ryohei [Division of Radiation Oncology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Morimoto, Koichi; Saito, Miki; Otsuki, Naoki; Nibu, Ken-ichi [Department of Otolaryngology-Head and Neck Surgery, Kobe University Graduate School of Medicine, Kobe (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan)

    2013-11-01

    Purpose: To assess the clinical value of retrospective image fusion of neck MRI and {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET for locoregional extension and nodal staging of neck cancer. Materials and methods: Thirty patients with carcinoma of the oral cavity or hypopharynx underwent PET/CT and contrast-enhanced neck MRI for initial staging before surgery including primary tumor resection and neck dissection. Diagnostic performance of PET/CT, MRI, and retrospective image fusion of PET and MRI (fused PET/MRI) for assessment of the extent of the primary tumor (T stage) and metastasis to regional lymph nodes (N stage) was evaluated. Results: Accuracy for T status was 87% for fused PET/MRI and 90% for MRI, thus proving significantly superior to PET/CT, which had an accuracy of 67% (p = 0.041 and p = 0.023, respectively). Accuracy for N status was 77% for both fused PET/MRI and PET/CT, being superior to MRI, which had an accuracy of 63%, although the difference was not significant (p = 0.13). On a per-level basis, the sensitivity, specificity and accuracy for detection of nodal metastasis were 77%, 96% and 93% for both fused PET/MRI and PET/CT, compared with 49%, 99% and 91% for MRI, respectively. The differences for sensitivity (p = 0.0026) and accuracy (p = 0.041) were significant. Conclusion: Fused PET/MRI combining the individual advantages of MRI and PET is a valuable technique for assessment of staging neck cancer.

  19. Toward cardiovascular MRI at 7 T: clinical needs, technical solutions and research promises

    International Nuclear Information System (INIS)

    Niendorf, Thoralf; Sodickson, Daniel K.; Krombach, Gabriele A.; Schulz-Menger, Jeanette

    2010-01-01

    To consider potential clinical needs, technical solutions and research promises of ultrahigh-field strength cardiovascular MR (CMR). A literature review is given, surveying advantages and disadvantages of CMR at ultrahigh fields (UHF). Key concepts, emerging technologies, practical considerations and applications of UHF CMR are provided. Examples of UHF CMR imaging strategies and their added value are demonstrated, including the numerous unsolved problems. A concluding section explores future directions in UHF CMR. UHF CMR can be regarded as one of the most challenging MRI applications. Image quality achievable at UHF is not always exclusively defined by signal-to-noise considerations. Some of the inherent advantages of UHF MRI are offset by practical challenges. But UHF CMR can boast advantages over its kindred lower field counterparts by trading the traits of high magnetic fields for increased temporal and/or spatial resolution. CMR at ultrahigh-field strengths is a powerful motivator, since speed and signal may be invested to overcome the fundamental constraints that continue to hamper traditional CMR. If practical challenges can be overcome, UHF CMR will help to open the door to new approaches for basic science and clinical research. (orig.)

  20. Opening the black box: imaging nanoparticle transport with MRI

    Science.gov (United States)

    Phoenix, V.; Holmes, W. M.

    2009-12-01

    While most renown for its use in medicine, magnetic resonance imaging (MRI) has tremendous potential in the study of environmental processes. Its ability to non-invasively image inside materials that are opaque to other imaging methods (in particular light based techniques) is a particular strength. MRI has already been used, for example, to study fluid flow in rocks and image mass transport and biogeochemical processes in biofilms [1-4]. Here, we report of the use of MRI to image nanoparticle transport through porous geologic media (in this case packed gravel columns). Packed column experiments are key to understanding nanoparticulate transport in porous geologic media. Whilst highly informative, the data obtained can be a bulk average of a complex and heterogeneous array of interactions within the column. Natural environmental systems are often complex, displaying heterogeneity in geometry, hydrodynamics, geochemistry and microbiology throughout. MRI enables us to quantify better how this heterogeneity may influence nanoparticle transport and fate by enabling us to look inside the column and image the movement of nanoparticles within. To make the nanoparticle readily visible to MRI, it is labelled with a paramagnetic tag (commonly gadolinium). Indeed, a wide variety of off-the-shelf paramagnetically tagged nanoparticles and macromolecules are available, each with different properties enabling us to explore the impact of particle charge, size etc on their transport behaviour. In this preliminary study, packed columns of quartz or marble based gravels (approx 5 mm diameter) were first imaged to check their suitability for MR imaging. This was done as geologic material can contain sufficiently high concentrations of ferro- and paramagnetic ions to induce unwanted artefacts in the MR image. All gravels imaged (Rose quartz, Creswick quartz gravel and Ben Deulin white marble) produced minimal or no artefacts. A solution of the nanoparticle GadoCELLTrack (BioPAL), was

  1. Fetal cerebral imaging - ultrasound vs. MRI: an update.

    Science.gov (United States)

    Blondiaux, Eléonore; Garel, Catherine

    2013-11-01

    The purpose of this article is to analyze the advantages and limitations of prenatal ultrasonography (US) and magnetic resonance imaging (MRI) in the evaluation of the fetal brain. These imaging modalities should not be seen as competitive but rather as complementary. There are wide variations in the world regarding screening policies, technology, skills, and legislation about termination of pregnancy, and these variations markedly impact on the way of using prenatal imaging. According to the contribution expected from each technique and to local working conditions, one should choose the most appropriate imaging modality on a case-by-case basis. The advantages and limitations of US and MRI in the setting of fetal brain imaging are displayed. Different anatomical regions (midline, ventricles, subependymal area, cerebral parenchyma, pericerebral space, posterior fossa) and pathological conditions are analyzed and illustrated in order to compare the respective contribution of each technique. An accurate prenatal diagnosis of cerebral abnormalities is of utmost importance for prenatal counseling.

  2. MRI, CT and TRUS imaging of seminal vesicle metastasis

    International Nuclear Information System (INIS)

    Larsson, P.; Blomqvist, L.; Norming, U.

    1997-01-01

    We present a case of a testicular germ-cell metastasis in the seminal vesicle. Diagnostic imaging with transrectal ultrasonography (TRUS), CT, and MRI was performed. This case emphasizes the role of MRI in the evaluation of patients with pathology in the pelvic region. (orig.)

  3. MRI of anterior cruciate ligament autografts

    International Nuclear Information System (INIS)

    Ogi, Shigeyuki; Ariizumi, Mitsuko; Yamagishi, Tsuneo; Agata, Toshihiko; Tada, Shinpei; Fukuda, Kunihiko

    2000-01-01

    The purpose of this study was to assess the usefulness of MRI in the evaluation of autografts after anterior cruciate ligament reconstruction. The subjects were 110 patients with anterior cruciate ligament reconstruction using patellar tendon autografts who underwent clinical examination, MRI, and arthroscopy of the knee. T1- and T2-weighted MR images were obtained in sagittal plane. Clinical findings were categorized into three groups: normal, borderline, and abnormal. The MRI appearances of the autografts were categorized into three types: straight continuous band (type I), interrupted band (type II) and generalized increased intensity band (type III). The clinical findings and MRI findings were compared with arthroscopic findings. Ninety-six percent of the type I showed no autograft tear on arthroscopy. In comparison with the clinical findings, MRI was found to be well correlated with arthroscopic findings. In conclusion, if the clinical findings are normal, patients are to be followed-up without MRI and arthroscopy. However, if clinical findings are either borderline or abnormal, MRI should be performed prior to arthroscopy. (author)

  4. Clinical and MRI outcome of an osteochondral scaffold plug for the treatment of cartilage lesions in the knee.

    Science.gov (United States)

    Dhollander, Aad; Verdonk, Peter; Almqvist, Karl Fredrik; Verdonk, Rene; Victor, Jan

    2015-12-01

    Conflicting clinical outcomes have been reported recently with the use of an osteochondral scaffold plugs for cartilage repair in the knee. In this study, twenty patients were consecutively treated for their cartilage lesions with the synthetic plug technique. These patients were prospectively clinically evaluated with a mean follow-up of 34.15 months. Magnetic resonance imaging (MRI) was used for morphologic analysis of the cartilage repair. The patients included in this study showed a significant gradual clinical improvement after the osteochondral scaffold plug. However, this clinical improvement was not confirmed by the MRI findings of this cohort study. Subchondral bone changes were seen in all patients on MRI and deficient filling of the defect was noticed in in 30.7% of the cases at 24 months of follow-up. There was no evidence found to support osteoconductive bone ingrowth. Therefore, the use of this type of osteochondral scaffold plug in osteochondral repair is questionable. Level of evidence: IV.

  5. MRI-only treatment planning: benefits and challenges

    Science.gov (United States)

    Owrangi, Amir M.; Greer, Peter B.; Glide-Hurst, Carri K.

    2018-03-01

    Over the past decade, the application of magnetic resonance imaging (MRI) has increased, and there is growing evidence to suggest that improvements in the accuracy of target delineation in MRI-guided radiation therapy may improve clinical outcomes in a variety of cancer types. However, some considerations should be recognized including patient motion during image acquisition and geometric accuracy of images. Moreover, MR-compatible immobilization devices need to be used when acquiring images in the treatment position while minimizing patient motion during the scan time. Finally, synthetic CT images (i.e. electron density maps) and digitally reconstructed radiograph images should be generated from MRI images for dose calculation and image guidance prior to treatment. A short review of the concepts and techniques that have been developed for implementation of MRI-only workflows in radiation therapy is provided in this document.

  6. A new MRI grading system for chondromalacia patellae.

    Science.gov (United States)

    Özgen, Ali; Taşdelen, Neslihan; Fırat, Zeynep

    2017-04-01

    Background Chondromalacia patellae is a very common disorder. Although magnetic resonance imaging (MRI) is widely used to investigate patellar cartilage lesions, there is no descriptive MRI-based grading system for chondromalacia patellae. Purpose To propose a new MRI grading system for chondromalacia patellae with corresponding high resolution images which might be useful in precisely reporting and comparing knee examinations in routine daily practice and used in predicting natural course and clinical outcome of the patellar cartilage lesions. Material and Methods High resolution fat-saturated proton density (FS PD) images in the axial plane with corresponding T2 mapping images were reviewed. A detailed MRI grading system covering the deficiencies of the existing gradings has been set and presented on these images. Two experienced observers blinded to clinical data examined 44 knee MR images and evaluated patellar cartilage changes according to the proposed grading system. Inter- and intra-rater validity testing using kappa statistics were calculated. Results A descriptive and detailed grading system with corresponding FS PD and T2 mapping images has been presented. Inter-rater agreement was 0.80 (95% confidence interval [CI], 0.71-0.89). Intra-rater agreements were 0.83 (95% CI, 0.74-0.91) for observer A and 0.79 (95% CI, 0.70-0.88) for observer B (k-values). Conclusion We present a new MRI grading system for chondromalacia patellae with corresponding images and good inter- and intra-rater agreement which might be useful in reporting and comparing knee MRI examinations in daily practice and may also have the potential for using more precisely predicting prognosis and clinical outcome of the patients.

  7. Imaging of cystic fibrosis lung disease and clinical interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Wielpuetz, M.O.; Eichinger, M.; Kauczor, H.U. [Heidelberg University Hospital (Germany). Dept. of Diagnostic and Interventional Radiology; Translational Lung Research Center Heidelberg (TLRC) (Germany); Heidelberg University Hospital (Germany). Dept. of Diagnostic and Interventional Radiology with Nuclear Medicine; Biederer, J. [Heidelberg University Hospital (Germany). Dept. of Diagnostic and Interventional Radiology; Translational Lung Research Center Heidelberg (TLRC) (Germany); Gross-Gerau Community Hospital (Germany). Radiologie Darmstadt; Wege, S. [Heidelberg University Hospital (Germany). Dept. of Pulmonology and Respiratory Medicine; Stahl, M.; Sommerburg, O. [Translational Lung Research Center Heidelberg (TLRC) (Germany); Heidelberg University Hospital (Germany). Div. of Pediatric Pulmonology and Allergy and Cystic Fibrosis Center; Mall, M.A. [Translational Lung Research Center Heidelberg (TLRC) (Germany); Heidelberg University Hospital (Germany). Div. of Pediatric Pulmonology and Allergy and Cystic Fibrosis Center; Heidelberg University Hospital (Germany). Dept. of Translational Pulmonology; Puderbach, M. [Heidelberg University Hospital (Germany). Dept. of Diagnostic and Interventional Radiology; Translational Lung Research Center Heidelberg (TLRC) (Germany); Heidelberg University Hospital (Germany). Dept. of Diagnostic and Interventional Radiology with Nuclear Medicine; Hufeland Hospital, Bad Langensalza (Germany). Dept. of Diagnostic and Interventional Radiology

    2016-09-15

    Progressive lung disease in cystic fibrosis (CF) is the life-limiting factor of this autosomal recessive genetic disorder. Increasing implementation of CF newborn screening allows for a diagnosis even in pre-symptomatic stages. Improvements in therapy have led to a significant improvement in survival, the majority now being of adult age. Imaging provides detailed information on the regional distribution of CF lung disease, hence longitudinal imaging is recommended for disease monitoring in the clinical routine. Chest X-ray (CXR), computed tomography (CT) and magnetic resonance imaging (MRI) are now available as routine modalities, each with individual strengths and drawbacks, which need to be considered when choosing the optimal modality adapted to the clinical situation of the patient. CT stands out with the highest morphological detail and has often been a substitute for CXR for regular severity monitoring at specialized centers. Multidetector CT data can be post-processed with dedicated software for a detailed measurement of airway dimensions and bronchiectasis and potentially a more objective and precise grading of disease severity. However, changing to CT was inseparably accompanied by an increase in radiation exposure of CF patients, a young population with high sensitivity to ionizing radiation and lifetime accumulation of dose. MRI as a cross-sectional imaging modality free of ionizing radiation can depict morphological hallmarks of CF lung disease at lower spatial resolution but excels with comprehensive functional lung imaging, with time-resolved perfusion imaging currently being most valuable.

  8. [Clinical application of MRI histogram in evaluation of muscle fatty infiltration].

    Science.gov (United States)

    Zheng, Y M; Du, J; Li, W Z; Wang, Z X; Zhang, W; Xiao, J X; Yuan, Y

    2016-10-18

    To describe a method based on analysis of the histogram of intensity values produced from the magnetic resonance imaging (MRI) for quantifying the degree of fatty infiltration. The study included 25 patients with dystrophinopathy. All the subjects underwent muscle MRI test at thigh level. The histogram M values of 250 muscles adjusted for subcutaneous fat, representing the degree of fatty infiltration, were compared with the expert visual reading using the modified Mercuri scale. There was a significant positive correlation between the histogram M values and the scores of visual reading (r=0.854, Phistogram M values was similar to that of visual reading and results in literature. The histogram M values had stronger correlations with the clinical data than the scores of visual reading as follows: the correlations with age (r=0.730, Phistogram M values analysis had better repeatability than visual reading with the interclass correlation coefficient was 0.998 (95% CI: 0.997-0.998, PHistogram M values analysis of MRI with the advantages of repeatability and objectivity can be used to evaluate the degree of muscle fatty infiltration.

  9. PCA-based groupwise image registration for quantitative MRI

    NARCIS (Netherlands)

    Huizinga, W.; Poot, D. H. J.; Guyader, J.-M.; Klaassen, R.; Coolen, B. F.; van Kranenburg, M.; van Geuns, R. J. M.; Uitterdijk, A.; Polfliet, M.; Vandemeulebroucke, J.; Leemans, A.; Niessen, W. J.; Klein, S.

    2016-01-01

    Quantitative magnetic resonance imaging (qMRI) is a technique for estimating quantitative tissue properties, such as the T5 and T2 relaxation times, apparent diffusion coefficient (ADC), and various perfusion measures. This estimation is achieved by acquiring multiple images with different

  10. Use of diffusion-weighted imaging (DWI) in PET/MRI for head and neck cancer evaluation

    International Nuclear Information System (INIS)

    Queiroz, Marcelo A.; Schulthess, Gustav von; Huellner, Martin; Kuhn, Felix; Veit-Haibach, Patrick; Huber, Gerhardt; Meerwein, Christian; Kollias, Spyros

    2014-01-01

    The purpose of this study was to analyze whether diffusion-weighted imaging (DWI) adds significant information to positron emission tomography/magnetic resonance imaging (PET/MRI) on lesion detection and characterization in head and neck cancers. Seventy patients with different head and neck cancers were enrolled in this prospective study. All patients underwent sequential contrast-enhanced (ce) PET/computed tomography (CT) and cePET/MRI using a tri-modality PET/CT-MR setup either for staging or re-staging. First, the DWI alone was evaluated, followed by the PET/MRI with conventional sequences, and in a third step, the PET/MRI with DWI was evaluated. McNemar's test was used to evaluate differences in the accuracy of PET/MRI with and without DWI compared to the standard of reference. One hundred eighty-eight (188) lesions were found, and of those, 118 (62.8 %) were malignant and 70 (37.2 %) were benign. PET/MRI without DWI had a higher accuracy in detecting malignant lesions than DWI alone (86.8 % vs. 60.6 %, p < 0.001). PET/MRI combined with DWI detected 120 concurrent lesions (89 malignant and 31 benign), PET/MRI alone identified 48 additional lesions (20 malignant and 28 benign), and DWI alone detected 20 different lesions (nine malignant and 11 benign). However, lesions detected on DWI did not change overall staging. SUV maximum and mean were significantly higher in malignant lesions than in benign lesions. DWI parameters between malignant and benign lesions were not statistically different. The use of DWI as part of PET/MRI to evaluate head and neck cancers does not provide remarkable information. Thus, the use of DWI might not be needed in clinical PET/MRI protocols for the staging or restaging of head and neck cancers. (orig.)

  11. Imaging of postthalamic visual fiber tracts by anisotropic diffusion weighted MRI and diffusion tensor imaging: principles and applications

    International Nuclear Information System (INIS)

    Reinges, Marcus H.T.; Schoth, Felix; Coenen, Volker A.; Krings, Timo

    2004-01-01

    Diffusion weighted MRI offers the possibility to study the course of the cerebral white matter tracts. In the present manuscript, the basics, the technique and the limitations of diffusion tensor imaging and anisotropic diffusion weighted MRI are presented and their applications in various neurological and neurosurgical diseases are discussed with special emphasis on the visual system. A special focus is laid on the combination of fiber tract imaging, anatomical imaging and functional MRI for presurgical planning and intraoperative neuronavigation of lesions near the visual system

  12. Clinico-pathomorphological study on schizophrenia using magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Uematsu, Masayuki

    1990-01-01

    Forty two schizophrenic patients and 28 normal controls underwent magnetic resonance imaging (MRI) examination of the brain. All subjects were consenting males under 50 years old. The enlargement of the third ventricle, anterior one third of the corpus callosum, and the septum pellucidum significantly differentiated schizophrenics from controls by a discriminant analysis. These findings may not be changes that appeared in the process of illness, but might have existed before the onset of the disorder. MRI measurements which significantly differentiated familial patients from non-familial patients using a discriminant analysis included the enlargement of the third ventricle, the cerebellar vermis, and the septum pellucidum. Negative symptoms and anergia symptoms depended on the degree of atrophy of the frontal lobe and the enlargement of the septum pellucidum. Poor heterosexual relations and low levels of education depended on the enlargement of the anterior one third of the corpus callosum. The good therapeutic response to neuroleptics in schizophrenics was associated with a small cerebellar vermis. All these findings suggested that combining morphological changes in the brain as illustrated by MRI with clinical variables may provide a useful new approach to subclassifying of schizophrenia. (author) 77 refs

  13. Near-real time oculodynamic MRI: a feasibility study for evaluation of diplopia in comparison with clinical testing

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Isabelle; Schwenzer-Zimmerer, Katja; Zeilhofer, Hans-Florian; Kunz, Christoph [University Hospital Basel, Hightech Research Center of Cranio-Maxillofacial Surgery and Dept. of Cranio-Maxillofacial Surgery, Basel (Switzerland); Palmowski-Wolfe, Anja [University of Basel, Department of Ophthalmology, Basel (Switzerland); Kober, Cornelia [HAW Hamburg, Faculty of Life Sciences, Hamburg (Germany); Radue, Ernst-Wilhelm [University Hospital Basel, Department of Neuroradiology, Basel (Switzerland); Scheffler, Klaus [University Hospital Basel, Division of Radiological Physics, Basel (Switzerland); Buitrago-Tellez, Carlos [Hightech Research Center of Cranio-Maxillofacial Surgery, Spital Zofingen AG, Institute of Radiology, Zofingen (Switzerland); University Hospital Basel, Zofingen (Switzerland)

    2012-02-15

    To demonstrate feasibility of near-real-time oculodynamic magnetic resonance imaging (od-MRI) in depicting extraocular muscles and correlate quantitatively the motion degree in comparison with clinical testing in patients with diplopia. In 30 od-MRIs eye movements were tracked in the horizontal and sagittal plane using a a TrueFISP sequence with high temporal resolution. Three physicians graded the visibility of extraocular muscles by a qualitative scale. In 12 cases, the maximal monocular excursions in the horizontal and vertical direction of both eyes were measured in od-MRIs and a clinical test and correlated by the Pearson test. The medial and lateral rectus muscles were visible in the axial plane in 93% of the cases. The oblique, superior and inferior rectus muscles were overall only in 14% visible. Horizontal (p = 0,015) and vertical (p = 0,029) movements of the right eye and vertical movement of the left eye (p = 0,026) measured by od-MRI correlated positively to the clinical measurements. Od-MRI is a feasible technique. Visualization of the horizontal/vertical rectus muscles is better than for the superior/inferior oblique muscle. Od-MRI correlates well with clinical testing and may reproduce the extent of eye bulb motility and extraocular muscle structural or functional deteriorations. (orig.)

  14. Magnetic resonance imaging in the evaluation of clinical treatment of otospongiosis: a pilot study.

    Science.gov (United States)

    de Oliveira Vicente, Andy; Chandrasekhar, Sujana S; Yamashita, Helio K; Cruz, Oswaldo Laercio M; Barros, Flavia A; Penido, Norma O

    2015-06-01

    To evaluate the applicability of magnetic resonance imaging (MRI) as a method for monitoring the activity of otospongiotic lesions before and after clinical treatment. Prospective, randomized, controlled, double-blind study. One single tertiary care institution in a large, cosmopolitan city. Twenty-six patients (n = 42 ears) with clinical, audiometric, and tomographic diagnosis of otosclerosis were enrolled. If computed tomography (CT) demonstrated active lesions, these patients underwent MRI to detect otospongiotic foci, seen as areas of gadolinium enhancement. Patients were divided into 3 groups and received treatment with placebo, sodium alendronate, or sodium fluoride for 6 months. After this period, clinical and audiometric evaluations and a second MRI were performed. Each MRI was evaluated by both a neuroradiologist and an otolaryngologist in a subjective (visual) and objective (using specific eFilm Workstation software) manner. Otospongiosis was most predominantly identified in the region anterior to the oval window, and this site was reliable for comparing pre- and posttreatment scans. The patients in the alendronate and sodium fluoride groups had MRI findings that suggested a decrease in activity of otospongiotic lesions, more relevant in the alendronate group. These findings were statistically significant for both subjective and objective MRI evaluations. MRI shows higher sensitivity than clinical or audiometric assessment for detecting reduction in activity of otospongiosis. The objective MRI evaluation based on software analysis was the most accurate method of monitoring clinical treatment response in otospongiosis. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  15. Complete Fourier Direct Magnetic Resonance Imaging (CFD-MRI for Diffusion MRI

    Directory of Open Access Journals (Sweden)

    Alpay eÖzcan

    2013-04-01

    Full Text Available The foundation for an accurate and unifying Fourier based theory of diffusion weighted magnetic resonance imaging (DW-MRI is constructed by carefully re-examining the first principles of DW-MRI signal formation and deriving its mathematical model from scratch. The derivations are specifically obtained for DW-MRI signal by including all of its elements (e.g., imaging gradients using complex values. Particle methods are utilized in contrast to conventional partial differential equations approach. The signal is shown to be the Fourier transform of the joint distribution of number of the magnetic moments (at a given location at the initial time and magnetic moment displacement integrals. In effect, the k-space is augmented by three more dimensions, corresponding to the frequency variables dual to displacement integral vectors. The joint distribution function is recovered by applying the Fourier transform to the complete high-dimensional data set. In the process, to obtain a physically meaningful real valued distribution function, phase corrections are applied for the re-establishment of Hermitian symmetry in the signal. Consequently, the method is fully unconstrained and directly presents the distribution of displacement integrals without any assumptions such as symmetry or Markovian property. The joint distribution function is visualized with isosurfaces, which describe the displacement integrals, overlaid on the distribution map of the number of magnetic moments with low mobility. The model provides an accurate description of the molecular motion measurements via DW-MRI. The improvement of the characterization of tissue microstructure leads to a better localization, detection and assessment of biological properties such as white matter integrity. The results are demonstrated on the experimental data obtained from an ex-vivo baboon brain.

  16. MRI diagnosis for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tamada, Tsutomu; Nagai, Kiyohisa; Imai, Shigeki; Kajihara, Yasumasa; Jo, Yoshimasa; Tanaka, Hiroyoshi; Fukunaga, Masao (Kawasaki Medical School, Kurashiki, Okayama (Japan)); Matsuki, Takakazu

    1998-01-01

    Recently, in Japan, both the Westernization of life styles and the advent of an aged-society have led to an increase in the incidence of prostate cancer. In making a localizing diagnosis of prostate cancer, magnetic resonance imaging (MRI), which has excellent contrast resolution, and transrectal ultrasonography, are used clinically, and their usefulness is being established. MRI is employed in the diagnosis of prostate cancer to detect tumors, and to determine the stage of such tumors. For the visualization of prostate cancer by MRI, T2-weighted axial images are used exclusively. After becoming familiar with normal prostate images, it is important to evaluate the localization of a tumor, and the invasion of the capsule and seminal vesicles. Future applications of new techniques for MRI will undoubtedly be found. In this paper, the present state of MRI diagnosis of prostate cancer at Kawasaki Medical School Hospital will be reviewed. (author)

  17. MRI diagnosis for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tamada, Tsutomu; Nagai, Kiyohisa; Imai, Shigeki; Kajihara, Yasumasa; Jo, Yoshimasa; Tanaka, Hiroyoshi; Fukunaga, Masao [Kawasaki Medical School, Kurashiki, Okayama (Japan); Matsuki, Takakazu

    1998-12-31

    Recently, in Japan, both the Westernization of life styles and the advent of an aged-society have led to an increase in the incidence of prostate cancer. In making a localizing diagnosis of prostate cancer, magnetic resonance imaging (MRI), which has excellent contrast resolution, and transrectal ultrasonography, are used clinically, and their usefulness is being established. MRI is employed in the diagnosis of prostate cancer to detect tumors, and to determine the stage of such tumors. For the visualization of prostate cancer by MRI, T2-weighted axial images are used exclusively. After becoming familiar with normal prostate images, it is important to evaluate the localization of a tumor, and the invasion of the capsule and seminal vesicles. Future applications of new techniques for MRI will undoubtedly be found. In this paper, the present state of MRI diagnosis of prostate cancer at Kawasaki Medical School Hospital will be reviewed. (author)

  18. Arrhythmogenic right ventricular dysplasia: MRI findings

    International Nuclear Information System (INIS)

    Wall, E.E. van der; Bootsma, M.M.; Schalij, M.J.; Kayser, H.W.M.; Roos, A. de

    2000-01-01

    Arrhythmogenic right ventricular dysplasia (ARVD) is a heart muscle disorder of unknown cause that is characterized pathologically by fibrofatty replacement of the right ventricular myocardium. Clinical manifestations include structural and functional malformations of the right ventricle, electrocardiographic abnormalities, and presentation with ventricular tachycardias with left bundle branch pattern or sudden death. The disease is often familial with an autosomal inheritance. In addition to right ventricular dilatation, right ventricular aneurysms are typical deformities of ARVD and they are distributed in the so-called ''triangle of dysplasia'', i. e., right ventricular outflow tract, apex, and infundibulum. Ventricular aneurysms at these sites can be considered pathognomonic of ARVD. Another typical hallmark of ARVD is fibrofatty infiltration of the right ventricular free wall. These functional and morphologic characteristics are relevant to clinical imaging investigations such as contrast angiography, echocardiography, radionuclide angiography, ultrafast computed tomography, and magnetic resonance imaging (MRI). Among these techniques, MRI allows the clearest visualization of the heart, in particular because the right ventricle is involved, which is usually more difficult to explore with the other imaging modalities. Furthermore, MRI offers the specific advantage of visualizing adipose infiltration as a bright signal of the right ventricular myocardium. MRI provides the most important anatomic, functional, and morphologic criteria for diagnosis of ARVD within one single study. As a result, MRI appears to be the optimal imaging technique for detecting and following patients with clinical suspicion of ARVD. (orig.) [de

  19. Multi-parametric MRI in cervical cancer. Early prediction of response to concurrent chemoradiotherapy in combination with clinical prognostic factors

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Wei; Chen, Bing; Wang, Ai Jun; Zhao, Jian Guo [The General Hospital of Ningxia Medical University, Department of Radiology, Yinchuan (China); Qiang, Jin Wei [Fudan University, Department of Radiology, Jinshan Hospital, Shanghai (China); Tian, Hai Ping [The General Hospital of Ningxia Medical University, Department of Pathology, Yinchuan (China)

    2018-01-15

    To investigate the prediction of response to concurrent chemoradiotherapy (CCRT) through a combination of pretreatment multi-parametric magnetic resonance imaging (MRI) with clinical prognostic factors (CPF) in cervical cancer patients. Sixty-five patients underwent conventional MRI, diffusion-weighted imaging (DWI), and dynamic contrast-enhanced MRI (DCE-MRI) before CCRT. The patients were divided into non- and residual tumour groups according to post-treatment MRI. Pretreatment MRI parameters and CPF between the two groups were compared and prognostic factors, optimal thresholds, and predictive performance for post-treatment residual tumour occurrence were estimated. The residual group showed a lower maximum slope of increase (MSI{sub L}) and signal enhancement ratio (SER{sub L}) in low-perfusion subregions, a higher apparent diffusion coefficient (ADC) value, and a higher stage than the non-residual tumour group (p < 0.001, p = 0.003, p < 0.001, and p < 0.001, respectively). MSI{sub L} and ADC were independent prognostic factors. The combination of both measures improved the diagnostic performance compared with individual MRI parameters. A further combination of these two factors with CPF exhibited the highest predictive performance. Pretreatment MSI{sub L} and ADC were independent prognostic factors for cervical cancer. The predictive capacity of multi-parametric MRI was superior to individual MRI parameters. The combination of multi-parametric MRI with CPF further improved the predictive performance. (orig.)

  20. WE-DE-206-04: MRI Pulse Sequences - Spin Echo, Gradient Echo, EPI, Non-Cartesia

    Energy Technology Data Exchange (ETDEWEB)

    Pooley, R. [Mayo Clinic (United States)

    2016-06-15

    Magnetic resonance imaging (MRI) has become an essential part of clinical imaging due to its ability to render high soft tissue contrast. Instead of ionizing radiation, MRI use strong magnetic field, radio frequency waves and field gradients to create diagnostic useful images. It can be used to image the anatomy and also functional and physiological activities within the human body. Knowledge of the basic physical principles underlying MRI acquisition is vitally important to successful image production and proper image interpretation. This lecture will give an overview of the spin physics, imaging principle of MRI, the hardware of the MRI scanner, and various pulse sequences and their applications. It aims to provide a conceptual foundation to understand the image formation process of a clinical MRI scanner. Learning Objectives: Understand the origin of the MR signal and contrast from the spin physics level. Understand the main hardware components of a MRI scanner and their purposes Understand steps for MR image formation including spatial encoding and image reconstruction Understand the main kinds of MR pulse sequences and their characteristics.

  1. Stroke MRI: pathophysiology, potential and perspectives

    International Nuclear Information System (INIS)

    Fiehler, J.; Kucinski, T.; Zeumer, H.

    2004-01-01

    Magnetic resonance imaging (MRT) is increasingly utilized as the primary imaging modality in major stroke centers. The ability to depict several aspects of individual pathophysiology makes the use of MRI in stroke both attractive and complex. Profound knowledge of the pathophysiology of the imaging findings is crucial for a rational diagnostic workup. The pathophysiology of MRI in stroke will be reviewed considering recent experiences in clinical application, and the potential of stroke MRI will be assessed. Further perspectives like application of 'blood oxygen level dependent' (BOLD) and the use of multiparametric prediction maps will be discussed. (orig.) [de

  2. Reflective THz and MR imaging of burn wounds: a potential clinical validation of THz contrast mechanisms

    Science.gov (United States)

    Bajwa, Neha; Nowroozi, Bryan; Sung, Shijun; Garritano, James; Maccabi, Ashkan; Tewari, Priyamvada; Culjat, Martin; Singh, Rahul; Alger, Jeffry; Grundfest, Warren; Taylor, Zachary

    2012-10-01

    Terahertz (THz) imaging is an expanding area of research in the field of medical imaging due to its high sensitivity to changes in tissue water content. Previously reported in vivo rat studies demonstrate that spatially resolved hydration mapping with THz illumination can be used to rapidly and accurately detect fluid shifts following induction of burns and provide highly resolved spatial and temporal characterization of edematous tissue. THz imagery of partial and full thickness burn wounds acquired by our group correlate well with burn severity and suggest that hydration gradients are responsible for the observed contrast. This research aims to confirm the dominant contrast mechanism of THz burn imaging using a clinically accepted diagnostic method that relies on tissue water content for contrast generation to support the translation of this technology to clinical application. The hydration contrast sensing capabilities of magnetic resonance imaging (MRI), specifically T2 relaxation times and proton density values N(H), are well established and provide measures of mobile water content, lending MRI as a suitable method to validate hydration states of skin burns. This paper presents correlational studies performed with MR imaging of ex vivo porcine skin that confirm tissue hydration as the principal sensing mechanism in THz burn imaging. Insights from this preliminary research will be used to lay the groundwork for future, parallel MRI and THz imaging of in vivo rat models to further substantiate the clinical efficacy of reflective THz imaging in burn wound care.

  3. Combined PET/MRI

    DEFF Research Database (Denmark)

    Bailey, D L; Pichler, B J; Gückel, B

    2018-01-01

    The 6th annual meeting to address key issues in positron emission tomography (PET)/magnetic resonance imaging (MRI) was held again in Tübingen, Germany, from March 27 to 29, 2017. Over three days of invited plenary lectures, round table discussions and dialogue board deliberations, participants c...... of response to pharmacological interventions and therapies. As such, PET/MRI is a key to advancing medicine and patient care.......The 6th annual meeting to address key issues in positron emission tomography (PET)/magnetic resonance imaging (MRI) was held again in Tübingen, Germany, from March 27 to 29, 2017. Over three days of invited plenary lectures, round table discussions and dialogue board deliberations, participants...... critically assessed the current state of PET/MRI, both clinically and as a research tool, and attempted to chart future directions. The meeting addressed the use of PET/MRI and workflows in oncology, neurosciences, infection, inflammation and chronic pain syndromes, as well as deeper discussions about how...

  4. Merits of magnetic resonance imaging (MRI) for the diagnosis of myositis ossificans circumscripta

    International Nuclear Information System (INIS)

    Bouchardy, L.; Garcia, J.

    1994-01-01

    A retrospective study of 5 cases, 4 of myositis ossificans circumscripta (MOC) and 1 of non-ossificans myositis, is presented. The clinical presentation was a painful soft-tissues swelling, and the final diagnosis was established by biopsy in 3 cases and clinical evolution in 2 cases. Different types of imaging techniques were performed: 4 MRI, 2 arteriographies, 3 Tc 99m scintigraphies, 3 US, 3 CT and plain film radiographs for all patients. MOC is a benign process (as opposed to myositis ossificans progressiva, which is an hereditary pathology with a fatal prognosis) with 3 phases of evolution: an acute or pseudo-inflammatory phase, a sub-acute or pseudo-tumoral phase and a chronic phase with a spontaneous healing. The radiologic diagnostic findings are dependent of the phase of the disease. The calcifications are seen earlier with scintigraphy than plain films, with US being less helpful. A heterogenous mass and calcifications are seen with CT. MRI allows the characterization of oedema during the acute phase and sometimes can exclude a malignant process. MRI is the best method for an early diagnosis, the differential diagnosis and to follow the evolution. (authors). 26 refs., 8 figs

  5. Unenhanced MR Imaging in adults with clinically suspected acute appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Chabanova, Elizaveta, E-mail: elcha@heh.regionh.dk [Department of Diagnostic Radiology, Copenhagen University Hospital at Herlev (Denmark); Balslev, Ingegerd, E-mail: inbal@heh.regionh.dk [Department of Pathology, Copenhagen University Hospital at Herlev (Denmark); Achiam, Michael, E-mail: micach01@heh.regionh.dk [Department of Gastrointestinal Surgery, Copenhagen University Hospital at Herlev (Denmark); Nielsen, Yousef W., E-mail: yujwni01@heh.regionh.dk [Department of Diagnostic Radiology, Copenhagen University Hospital at Herlev (Denmark); Adamsen, Sven, E-mail: svad@heh.regionh.dk [Department of Gastrointestinal Surgery, Copenhagen University Hospital at Herlev (Denmark); Gocht-Jensen, Peter, E-mail: petgoc01@heh.reginh.dk [Department of Gastrointestinal Surgery, Copenhagen University Hospital at Herlev (Denmark); Brisling, Steffen K., E-mail: stkibr01@heh.regionh.dk [Department of Gastrointestinal Surgery, Copenhagen University Hospital at Herlev (Denmark); Logager, Vibeke B., E-mail: viloe@heh.regionh.dk [Department of Diagnostic Radiology, Copenhagen University Hospital at Herlev (Denmark); Thomsen, Henrik S., E-mail: heth@heh.regionh.dk [Department of Diagnostic Radiology, Copenhagen University Hospital at Herlev (Denmark)

    2011-08-15

    Purpose: The purpose of the study was to evaluate unenhanced Magnetic Resonance Imaging (MRI) for the diagnosis of appendicitis or another surgery-requiring condition in an adult population scheduled for emergency appendectomy based on a clinical diagnosis of suspected acute appendicitis. Materials and methods: The prospective study included 48 consecutive patients (29 female, 19 male, 18-70 years old, mean age = 37.1 years). MRI examination was designed to be comfortable and fast; no contrast was administered. The sequences were performed during quiet respiration. The MRI findings were reviewed by two radiologists and one surgeon independent of each other and compared with surgical and pathological records. Results: According to the surgical and histopathological findings 30 of 48 patients (63%) had acute appendicitis. Of the remaining 18 patients, 4 patients had no reasons for the clinical symptoms and 14 patients had other pathology. For the three reviewers the performance of MRI in the diagnosis of acute appendicitis showed the following sensitivity, specificity and accuracy ranges: 83-93%, 50-83% and 77-83%. Moderate ({kappa} = 0.51) and fair ({kappa} = 0.31) interobserver agreements in the MR diagnosis of acute appendicitis were found between the reviewers. Sensitivity, specificity and accuracy values for overall performance of MRI in detecting pelvic abnormalities were 100%, 75% (3 of 4 healthy patients were identified by MRI) and 98%, respectively. Conclusion: Unenhanced fast MRI is feasible as an additional fast screening before the appendectomy. It may prevent unnecessary surgeries. The fast MRI examination can be adequately performed on an MRI unit of broad range of field strengths.

  6. Low-Cost High-Performance MRI

    Science.gov (United States)

    Sarracanie, Mathieu; Lapierre, Cristen D.; Salameh, Najat; Waddington, David E. J.; Witzel, Thomas; Rosen, Matthew S.

    2015-10-01

    Magnetic Resonance Imaging (MRI) is unparalleled in its ability to visualize anatomical structure and function non-invasively with high spatial and temporal resolution. Yet to overcome the low sensitivity inherent in inductive detection of weakly polarized nuclear spins, the vast majority of clinical MRI scanners employ superconducting magnets producing very high magnetic fields. Commonly found at 1.5-3 tesla (T), these powerful magnets are massive and have very strict infrastructure demands that preclude operation in many environments. MRI scanners are costly to purchase, site, and maintain, with the purchase price approaching $1 M per tesla (T) of magnetic field. We present here a remarkably simple, non-cryogenic approach to high-performance human MRI at ultra-low magnetic field, whereby modern under-sampling strategies are combined with fully-refocused dynamic spin control using steady-state free precession techniques. At 6.5 mT (more than 450 times lower than clinical MRI scanners) we demonstrate (2.5 × 3.5 × 8.5) mm3 imaging resolution in the living human brain using a simple, open-geometry electromagnet, with 3D image acquisition over the entire brain in 6 minutes. We contend that these practical ultra-low magnetic field implementations of MRI (standards for affordable (<$50,000) and robust portable devices.

  7. Requirements to MRI and MRS data to be applicable for radiation treatment

    International Nuclear Information System (INIS)

    Torresin, A.; Brambilla, M.; Colombo, P.; Minella, M.; Monti, A.; Moscato, A.

    2012-01-01

    Magnetic Resonance Imaging (MRI) use for Radiotherapy planning began in the 1980 and is still developing today. MRI is now an important morphological and functional imaging able to open new diagnostic and planning scenario. As new technologies become more complex, their best clinical application often becomes very difficult. The intent of this paper is to highlight methods and requirements necessary to apply MRI in radiation treatments. The concept of image is still in progress, following the evolution of human body knowledge. Many different methods to get diagnostic information of a tumour will be acquired; MRI images will be more and more important in the next future. The combination of information from complementary imaging modalities is expected to have a great benefit in cancer treatment. This fact is particularly relevant for target definition, which remains, one of the most important sources of error in Radiotherapy. Anatomical imaging with CT and MRI produces different gross tumour volumes. Functional imaging with modalities such as MRI and PET will generally reveal an even different volume. Thus a decision has to be taken about how to combine such information in clinical applications. The solutions of these new problems are 'in progress' and a lot of researches in clinical applications are in discussion

  8. Anatomy of the shoulder - clinical aspects for imaging and anatomical varieties

    International Nuclear Information System (INIS)

    Vahlensieck, M.

    2004-01-01

    Knowledge of anatomic details is important for interpretation of diagnostic imaging particularly MRI and CT. New findings even in macroscopy in the last years increased our knowledge significantly. In this article the findings are summarized with emphasis on clinical aspects. (orig.) [de

  9. Renal dysplasia and MRI: a clinician's perspective

    Energy Technology Data Exchange (ETDEWEB)

    Greenbaum, Larry A. [Emory University, Division of Pediatric Nephrology, Children' s Healthcare of Atlanta, Atlanta, GA (United States)

    2008-01-15

    Renal dysplasia is a common abnormality in children. The role of MRI in evaluating children with renal dysplasia is evolving. More information is clearly necessary before MRI replaces conventional imaging modalities. In order to appropriately use MRI, the radiologist must have an understanding of the clinical questions that are important in the management of children with renal dysplasia. This review provides background information on renal dysplasia for the pediatric radiologist. The focus is on unilateral disease, especially multicystic dysplastic kidneys, and bilateral dysplasia, which is the most common cause of kidney failure in children. The emphasis is on the important clinical issues, and the potential of MRI as a methodology for providing clinically useful information not otherwise available from other imaging modalities. (orig.)

  10. Measurement and imaging of brain function using MRI, MEG, and TMS

    International Nuclear Information System (INIS)

    Iramina, Keiji

    2008-01-01

    This paper reviews functional imaging techniques in neuroscience such as magnetic resonance imaging (MRI) functional MRI (fMRI), magnetoencephalogray (MEG), and transcranial magnetic stimulation (TMS). fMRI and MEG allow the neuronal activity of the brain to be measured non-invasively. MEG detects an electrical activity as neuronal activity, while, fMRI detects a hemodynamic response as neuronal activity. TMS is the application of a brief magnetic pulse or a train of pulses to the skull, which results in the induction of a local electric current in the underlying surface of the brain, thereby producing a localized axonal depolarization. As a non-invasive and effective method to make reversible lesions in the human brain, TMS has a long and successful history. All of these techniques have major potential for applications in the neuroscience and medicine. (author)

  11. The Value of Neurosurgical and Intraoperative Magnetic Resonance Imaging and Diffusion Tensor Imaging Tractography in Clinically Integrated Neuroanatomy Modules: A Cross-Sectional Study

    Science.gov (United States)

    Familiari, Giuseppe; Relucenti, Michela; Heyn, Rosemarie; Baldini, Rossella; D'Andrea, Giancarlo; Familiari, Pietro; Bozzao, Alessandro; Raco, Antonino

    2013-01-01

    Neuroanatomy is considered to be one of the most difficult anatomical subjects for students. To provide motivation and improve learning outcomes in this area, clinical cases and neurosurgical images from diffusion tensor imaging (DTI) tractographies produced using an intraoperative magnetic resonance imaging apparatus (MRI/DTI) were presented and…

  12. Automatic delineation of brain regions on MRI and PET images from the pig.

    Science.gov (United States)

    Villadsen, Jonas; Hansen, Hanne D; Jørgensen, Louise M; Keller, Sune H; Andersen, Flemming L; Petersen, Ida N; Knudsen, Gitte M; Svarer, Claus

    2018-01-15

    The increasing use of the pig as a research model in neuroimaging requires standardized processing tools. For example, extraction of regional dynamic time series from brain PET images requires parcellation procedures that benefit from being automated. Manual inter-modality spatial normalization to a MRI atlas is operator-dependent, time-consuming, and can be inaccurate with lack of cortical radiotracer binding or skull uptake. A parcellated PET template that allows for automatic spatial normalization to PET images of any radiotracer. MRI and [ 11 C]Cimbi-36 PET scans obtained in sixteen pigs made the basis for the atlas. The high resolution MRI scans allowed for creation of an accurately averaged MRI template. By aligning the within-subject PET scans to their MRI counterparts, an averaged PET template was created in the same space. We developed an automatic procedure for spatial normalization of the averaged PET template to new PET images and hereby facilitated transfer of the atlas regional parcellation. Evaluation of the automatic spatial normalization procedure found the median voxel displacement to be 0.22±0.08mm using the MRI template with individual MRI images and 0.92±0.26mm using the PET template with individual [ 11 C]Cimbi-36 PET images. We tested the automatic procedure by assessing eleven PET radiotracers with different kinetics and spatial distributions by using perfusion-weighted images of early PET time frames. We here present an automatic procedure for accurate and reproducible spatial normalization and parcellation of pig PET images of any radiotracer with reasonable blood-brain barrier penetration. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Experimental and clinical studies of fast three-dimensional MR imaging of the heart

    International Nuclear Information System (INIS)

    Sato, Shuhei

    1999-01-01

    MRI has been utilized since its inception to study the anatomy and physiology of the heart. However, the sensitivity of MRI to motion has always posed a major challenge in imaging this organ. The purpose of this study was to develop a 3D MP-RAGE technique for the heart, and to apply it clinically. In the experimental study, data acquisition timing was discussed by normal volunteers. Changes in magnetization recovery time affected imaging contrast very little in the phantom study. Fourteen adults and 21 children were examined. In the adults, MP-RAGE images were rated as high in quality in the visual estimation. In the quantitative estimation, the images provided almost the same anatomical information as those of cine MRI. In the children, MP-RAGE was useful for cases of partial anomalous pulmonary venous drainage, particularly in the evaluation of abnormal pulmonary veins. The 3D MP-RAGE technique was useful in imaging the heart because it was possible to obtain continuous views in the same cardiac cycle and to reconstruct views from any direction after the examination. (author)

  14. Experimental and clinical studies of fast three-dimensional MR imaging of the heart

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Shuhei [Okayama Univ. (Japan). School of Medicine

    1999-07-01

    MRI has been utilized since its inception to study the anatomy and physiology of the heart. However, the sensitivity of MRI to motion has always posed a major challenge in imaging this organ. The purpose of this study was to develop a 3D MP-RAGE technique for the heart, and to apply it clinically. In the experimental study, data acquisition timing was discussed by normal volunteers. Changes in magnetization recovery time affected imaging contrast very little in the phantom study. Fourteen adults and 21 children were examined. In the adults, MP-RAGE images were rated as high in quality in the visual estimation. In the quantitative estimation, the images provided almost the same anatomical information as those of cine MRI. In the children, MP-RAGE was useful for cases of partial anomalous pulmonary venous drainage, particularly in the evaluation of abnormal pulmonary veins. The 3D MP-RAGE technique was useful in imaging the heart because it was possible to obtain continuous views in the same cardiac cycle and to reconstruct views from any direction after the examination. (author)

  15. Understanding Patient Preference in Female Pelvic Imaging: Transvaginal Ultrasound and MRI.

    Science.gov (United States)

    Sakala, Michelle D; Carlos, Ruth C; Mendiratta-Lala, Mishal; Quint, Elisabeth H; Maturen, Katherine E

    2018-04-01

    Women with pelvic pain or abnormal uterine bleeding may undergo diagnostic imaging. This study evaluates patient experience in transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI) and explores correlations between preference and symptom severity. Institutional review board approval was obtained for this Health Insurance Portability and Accountability Act-compliant prospective study. Fifty premenopausal women with pelvic symptoms evaluated by recent TVUS and MRI and without history of gynecologic cancer or hysterectomy were included. A phone questionnaire used validated survey instruments including Uterine Fibroid Symptoms Quality of Life index, Testing Morbidities Index, and Wait Trade Off for TVUS and MRI examinations. Using Wait Trade Off, patients preferred TVUS over MRI (3.58 vs 2.80 weeks, 95% confidence interval [CI] -1.63, 0.12; P = .08). Summary test utility of Testing Morbidities Index for MRI was worse than for TVUS (81.64 vs 87.42, 95%CI 0.41, 11.15; P = .03). Patients reported greater embarrassment during TVUS than during MRI (P MRI, and greater mental (P = .02) and physical (P = .02) problems after MRI versus TVUS. Subscale correlations showed physically inactive women rated TVUS more negatively (R = -0.32, P = .03), whereas women with more severe symptoms of loss of control of health (R = -0.28, P = .04) and sexual dysfunction (R = -0.30, P = .03) rated MRI more negatively. Women with pelvic symptoms had a slight but significant preference for TVUS over MRI. Identifying specific distressing aspects of each test and patient factors contributing to negative perceptions can direct improvement in both test environment and patient preparation. Improved patient experience may increase imaging value. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  16. Volumetric BOLD fMRI simulation: from neurovascular coupling to multivoxel imaging

    International Nuclear Information System (INIS)

    Chen, Zikuan; Calhoun, Vince

    2012-01-01

    The blood oxygenation-level dependent (BOLD) functional magnetic resonance imaging (fMRI) modality has been numerically simulated by calculating single voxel signals. However, the observation on single voxel signals cannot provide information regarding the spatial distribution of the signals. Specifically, a single BOLD voxel signal simulation cannot answer the fundamental question: is the magnetic resonance (MR) image a replica of its underling magnetic susceptibility source? In this paper, we address this problem by proposing a multivoxel volumetric BOLD fMRI simulation model and a susceptibility expression formula for linear neurovascular coupling process, that allow us to examine the BOLD fMRI procedure from neurovascular coupling to MR image formation. Since MRI technology only senses the magnetism property, we represent a linear neurovascular-coupled BOLD state by a magnetic susceptibility expression formula, which accounts for the parameters of cortical vasculature, intravascular blood oxygenation level, and local neuroactivity. Upon the susceptibility expression of a BOLD state, we carry out volumetric BOLD fMRI simulation by calculating the fieldmap (established by susceptibility magnetization) and the complex multivoxel MR image (by intravoxel dephasing). Given the predefined susceptibility source and the calculated complex MR image, we compare the MR magnitude (phase, respectively) image with the predefined susceptibility source (the calculated fieldmap) by spatial correlation. The spatial correlation between the MR magnitude image and the magnetic susceptibility source is about 0.90 for the settings of T E = 30 ms, B 0 = 3 T, voxel size = 100 micron, vessel radius = 3 micron, and blood volume fraction = 2%. Using these parameters value, the spatial correlation between the MR phase image and the susceptibility-induced fieldmap is close to 1.00. Our simulation results show that the MR magnitude image is not an exact replica of the magnetic susceptibility

  17. Cognitive impairment, clinical severity and MRI changes in MELAS syndrome.

    Science.gov (United States)

    Kraya, Torsten; Neumann, Lena; Paelecke-Habermann, Yvonne; Deschauer, Marcus; Stoevesandt, Dietrich; Zierz, Stephan; Watzke, Stefan

    2017-12-29

    To examine clinical severity, cognitive impairment, and MRI changes in patients with MELAS syndrome. Cognitive-mnestic functions, brain MRI (lesion load, cella media index) and clinical severity of ten patients with MELAS syndrome were examined. All patients carried the m.3243A>G mutation. The detailed neuropsychological assessment revealed cognitive deficits in attention, executive function, visuoperception, and -construction. There were significant correlations between these cognitive changes, lesion load in MRI, disturbances in everyday life (clinical scale), and high scores in NMDAS. Patients with MELAS syndrome showed no global neuropsychological deficit, but rather distinct cognitive deficits. Copyright © 2018 Elsevier B.V. and Mitochondria Research Society. All rights reserved.

  18. Clinical and imaging assessment of cognitive dysfunction in multiple sclerosis

    DEFF Research Database (Denmark)

    Rocca, Maria A; Amato, Maria P; De Stefano, Nicola

    2015-01-01

    In patients with multiple sclerosis (MS), grey matter damage is widespread and might underlie many of the clinical symptoms, especially cognitive impairment. This relation between grey matter damage and cognitive impairment has been lent support by findings from clinical and MRI studies. However...... that causes clinical symptoms to trigger. Findings on cortical reorganisation support the contribution of brain plasticity and cognitive reserve in limiting cognitive deficits. The development of clinical and imaging biomarkers that can monitor disease development and treatment response is crucial to allow...

  19. Intramuscular leukemic relapse: clinical signs and imaging findings. A multicentric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Surov, Alexey [Martin Luther University Halle-Wittenberg, Department of Radiology, Halle (Germany); University of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Kiratli, Hayyam [Hacettepe University School of Medicine, Department of Ophthalmology, Ankara (Turkey); Im, Soo Ah [Seoul St. Mary' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Manabe, Yasuhiro [National Hospital Organization Okayama Medical Center, Department of Neurology, Okayama (Japan); O' Neill, Alibhe; Shinagare, Atul B. [Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); Spielmann, Rolf Peter [Martin Luther University Halle-Wittenberg, Department of Radiology, Halle (Germany)

    2014-09-26

    Leukemia is a group of malignant diseases involving peripheral blood and bone marrow. Extramedullary tumor manifestation in leukemia can also occur. They more often involve lymph nodes, skin, and bones. Intramuscular leukemic relapse (ILR) is very unusual. The aim of this analysis was to summarize the reported data regarding clinical signs and radiological features of ILR. The PubMed database was searched for publications related to ILR. After an analysis of all identified articles, 20 publications matched the inclusion criteria. The authors of the 20 publications were contacted and provided imaging of their cases for review. The following were recorded: age, gender, primary diagnosis, clinical signs, pattern, localization and size of the intramuscular leukemic relapse. Images of 16 patients were provided [8 computer tomographic (CT) images and 15 magnetic resonance images, MRI]. Furthermore, one patient with ILR was identified in our institutional database. Therefore, images of 17 patients were available for further analysis. Overall, 32 cases with ILR were included in the analysis. In most cases acute myeloid leukemia was diagnosed. Most ILRs were localized in the extremities (44 %) and in the extraocular muscles (44 %). Clinically, ILR manifested as local pain, swelling and muscle weakness. Radiologically, ILR presented most frequently with diffuse muscle infiltration. On postcontrast CT/MRI, most lesions demonstrated homogeneous enhancement. ILRs were hypo-/isointense on T1w and hyperintense on T2w images. ILR manifests commonly as focal pain, swelling and muscle weakness. ILR predominantly involved the extraocular musculature and the extremities. Radiologically, diffuse muscle infiltration was the most common imaging finding. (orig.)

  20. Does the individual adaption of standardized speech paradigmas for clinical functional Magnetic Resonance Imaging (fMRI) effect the localization of the language-dominant hemisphere and of Broca's and Wernicke's areas

    International Nuclear Information System (INIS)

    Konrad, F.; Nennig, E.; Kress, B.; Sartor, K.; Stippich, C.; Ochmann, H.

    2005-01-01

    Purpose: Functional magnetic resonance imaging (fMRI) localizes Broca's area (B) and Wernicke's area (W) and the hemisphere dominant for language. In clinical fMRI, adapting the stimulation paradigms to each patient's individual cognitive capacity is crucial for diagnostic success. To interpret clinical fMRI findings correctly, we studied the effect of varying frequency and number of stimuli on functional localization, determination of language dominance and BOLD signals. Materials and Methods: Ten volunteers (VP) were investigated at 1.5 Tesla during visually triggered sentence generation using a standardized block design. In four different measurements, the stimuli were presented to each VP with frequencies of (1/1)s, (1/2)s,(1/3)s and (1/6)s. Results: The functional localizations and the correlations of the measured BOLD signals to the applied hemodynamic reference function (r) were almost independent from frequency and number of the stimuli in both hemispheres, whereas the relative BOLD signal changes (ΔS) in B and W increased with the stimulation rate, which also changed the lateralization indices. The strongest BOLD activations were achieved with the highest stimulation rate or with the maximum language production task, respectively. Conclusion: The adaptation of language paradigms necessary in clinical fMRI does not alter the functional localizations but changes the BOLD signals and language lateralization which should not be attributed to the underlying brain pathology. (orig.)