WorldWideScience

Sample records for clinical diagnostic application

  1. [Advances of Molecular Diagnostic Techniques Application in Clinical Diagnosis.

    Science.gov (United States)

    Ying, Bin-Wu

    2016-11-01

    Over the past 20 years,clinical molecular diagnostic technology has made rapid development,and became the most promising field in clinical laboratory medicine.In particular,with the development of genomics,clinical molecular diagnostic methods will reveal the nature of clinical diseases in a deeper level,thus guiding the clinical diagnosis and treatments.Many molecular diagnostic projects have been routinely applied in clinical works.This paper reviews the advances on application of clinical diagnostic techniques in infectious disease,tumor and genetic disorders,including nucleic acid amplification,biochip,next-generation sequencing,and automation molecular system,and so on.

  2. Clinical applications of SONIALVISION 100 digital diagnostic table system

    International Nuclear Information System (INIS)

    Shiomi, Takeshi; Shimizu, Tatsuya; Iinuma, Masao; Takemoto, Hajime; Tanaka, Shuji

    2003-01-01

    This report refers to the clinical applications of our newly developed SONIALVISION 100 fully digitalized X-ray diagnostic table system. The main design concept of the SONIALVISION 100 system is the improvement of workflow in various clinical fields. The development of digital imaging technologies has come to allow fully digitalized X-ray diagnostic table systems to be widely utilized in various clinical applications, including interventional radiology (IVR) and examinations using contrast medium. This report mainly refers to the clinical applications of the Shimadzu SONIALVISION 100 digitalized X-ray diagnostic table system, also presenting some typical image data demonstrating the high efficiency, made available through the use of this new system, in high-speed spot imaging and digital tomography. (author)

  3. Application of Next-generation Sequencing in Clinical Molecular Diagnostics

    Directory of Open Access Journals (Sweden)

    Morteza Seifi

    2017-05-01

    Full Text Available ABSTRACT Next-generation sequencing (NGS is the catch all terms that used to explain several different modern sequencing technologies which let us to sequence nucleic acids much more rapidly and cheaply than the formerly used Sanger sequencing, and as such have revolutionized the study of molecular biology and genomics with excellent resolution and accuracy. Over the past years, many academic companies and institutions have continued technological advances to expand NGS applications from research to the clinic. In this review, the performance and technical features of current NGS platforms were described. Furthermore, advances in the applying of NGS technologies towards the progress of clinical molecular diagnostics were emphasized. General advantages and disadvantages of each sequencing system are summarized and compared to guide the selection of NGS platforms for specific research aims.

  4. Clinical diagnostic ultrasound

    International Nuclear Information System (INIS)

    Barnett, E.; Morley, P.

    1986-01-01

    This textbook on diagnostic ultrasound covers the main systems, with emphasis being placed on the clinical application of diagnostic ultrasound in everyday practice. It provides not only a textbook for postgraduates (particularly FRCR candidates), but also a reference work for practitioners of clinical ultrasound and clinicians generally

  5. Application of Quality Assurance Strategies in Diagnostics and Clinical Support Services in Iranian Hospitals

    NARCIS (Netherlands)

    Aghaei Hashjin, Asgar; Kringos, Dionne; Ravaghi, Hamid; Manoochehri, Jila; Gorji, Hassan Abolghasem; Klazinga, Niek S.

    2015-01-01

    Background: Iran has a widespread diagnostics and clinical support services (DCSS) network that plays a crucial role in providing diagnostic and clinical support services to both inpatient and outpatient care. However, very little is known on the application of quality assurance (QA) policies in

  6. Clinical Applications of the Eosinophilic Esophagitis Diagnostic Panel

    Directory of Open Access Journals (Sweden)

    Ting Wen

    2017-07-01

    Full Text Available Eosinophilic esophagitis (EoE is a recently recognized upper gastrointestinal allergic disorder characterized by esophageal dysfunction (e.g., dysphagia and esophageal eosinophilia of ≥15 eosinophils/high-power field in patients who have persistent esophagitis even on proton pump inhibitor (PPI therapy. The histologic method is the gold standard of EoE diagnosis. However, EoE clinical symptoms do not always correlate with histology, and the histologic method has sensitivity and specificity issues due to the patchiness of EoE and the subjective nature of the method. The “EoE transcriptome” was initially discovered in 2006, which led to the invention of the EoE diagnostic panel (EDP. In addition to providing a definitive EoE diagnosis with high accuracy, the EDP has been useful in elucidating several key elements about the disease including the efficacy of specific drugs such as swallowed glucocorticoids and anti-IL-13 humanized antibody therapy, the relationship between EoE and PPI-responsive esophageal eosinophilia, and predicting the disease course and responsiveness to therapy. The EDP’s long-term potential arises from its plasticity to incorporate new genes and uncover novel disease pathogenesis. We expect that the EDP will be increasingly helpful for personalized medicine approaches and improved diagnostics and disease monitoring.

  7. 76 FR 28990 - Ultra High Throughput Sequencing for Clinical Diagnostic Applications-Approaches To Assess...

    Science.gov (United States)

    2011-05-19

    ... Web cast of the public meeting, you must register online at http://www.fda.gov/MedicalDevices/News... technologies are currently extensively used in research and are entering clinical diagnostic use; they are... technologies for clinical applications, appropriate evaluation tools (e.g., standards, well established...

  8. Executive summary of the Diagnostic Criteria for Temporomandibular Disorders for clinical and research applications.

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard

    2016-06-01

    In this executive summary, the authors describe a protocol for assessing patients with temporomandibular disorder (TMD). It is based on the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for clinical and research applications. The DC/TMD was developed using published Axis I physical diagnoses for the most common TMDs. Axis I diagnostic criteria were derived from pertinent clinical TMD signs and symptoms. Axis II consists of psychosocial and behavioral questionnaires already in the public domain. A panel of experts vetted and modified the Axis I and Axis II diagnostic protocols. Recommended changes were assessed for diagnostic accuracy by using the Validation Project's data set, which formed the basis for the development of the DC/TMD. Axis I diagnostic criteria for TMD pain-related disorders have acceptable validity and provide definitive diagnoses for pain involving the temporomandibular joint (TMJ) and masticatory muscles. Axis I diagnostic criteria for the most common TMJ intra-articular disorders are appropriate for screening purposes only. A definitive diagnosis for TMJ intra-articular disorders requires computed tomography or magnetic resonance imaging. Axis II questionnaires provide valid assessment of psychosocial and behavioral factors that can affect management of TMD. The DC/TMD provides a questionnaire for the pain history in conjunction with validated clinical examination criteria for diagnosing the most common TMDs. In addition, it provides Axis II questionnaires for assessing psychosocial and behavioral factors that may contribute to the onset and perpetuation of the patient's TMD. The DC/TMD is appropriate for use in clinical and research settings to allow for a comprehensive assessment of patients with TMD. Copyright © 2016 American Dental Association. Published by Elsevier Inc. All rights reserved.

  9. Application of Quality Assurance Strategies in Diagnostics and Clinical Support Services in Iranian Hospitals

    Science.gov (United States)

    Aghaei Hashjin, Asgar; Kringos, Dionne; Ravaghi, Hamid; Manoochehri, Jila; Gorji, Hassan Abolghasem; Klazinga, Niek S.

    2015-01-01

    Background: Iran has a widespread diagnostics and clinical support services (DCSS) network that plays a crucial role in providing diagnostic and clinical support services to both inpatient and outpatient care. However, very little is known on the application of quality assurance (QA) policies in DCSS units. This study explores the extent of application of eleven QA strategies in DCSS units within Iranian hospitals and its association with hospital characteristics. Methods: A descriptive cross-sectional study was conducted in 2009/2010. Data were collected from 554 DCSS units among 84 hospitals. Results: The average reported application rate for the QA strategies ranged from 57%-94% in the DCSS units. Most frequently reported were checking drugs expiration dates (94%), pharmacopoeia availability (92%), equipment calibration (87%) and identifying responsibilities (86%). Least reported was external auditing of the DCSS (57%). The clinical chemistry and microbiology laboratories (84%), pharmacies, blood bank services (83%) reported highest average application rates across all questioned QA strategies. Lowest application rates were reported in human tissue banks (50%). There was no significant difference between the reported application rates in DCSS in the general/specialized, teaching/research, nonteaching/research hospitals with the exception of pharmacies and radiology departments. They reported availability of a written QA plan significantly more often in research hospitals. Nearly all QA strategies were reported to be applied significantly more often in the DCSS of Social Security Organization (SSO) and private-for-profit hospitals than in governmental hospitals. Conclusion: There is still room for strengthening the managerial cycle of QA systems and accountability in the DCSS in Iranian hospitals. Getting feedback, change and learning through application of specific QA strategies (eg, external/internal audits) can be improved. Both the effectiveness of QA

  10. Application of Quality Assurance Strategies in Diagnostics and Clinical Support Services in Iranian Hospitals.

    Science.gov (United States)

    Aghaei Hashjin, Asgar; Kringos, Dionne; Ravaghi, Hamid; Manoochehri, Jila; Gorji, Hassan Abolghasem; Klazinga, Niek S

    2015-05-20

    Iran has a widespread diagnostics and clinical support services (DCSS) network that plays a crucial role in providing diagnostic and clinical support services to both inpatient and outpatient care. However, very little is known on the application of quality assurance (QA) policies in DCSS units. This study explores the extent of application of eleven QA strategies in DCSS units within Iranian hospitals and its association with hospital characteristics. A descriptive cross-sectional study was conducted in 2009/2010. Data were collected from 554 DCSS units among 84 hospitals. The average reported application rate for the QA strategies ranged from 57%-94% in the DCSS units. Most frequently reported were checking drugs expiration dates (94%), pharmacopoeia availability (92%), equipment calibration (87%) and identifying responsibilities (86%). Least reported was external auditing of the DCSS (57%). The clinical chemistry and microbiology laboratories (84%), pharmacies, blood bank services (83%) reported highest average application rates across all questioned QA strategies. Lowest application rates were reported in human tissue banks (50%). There was no significant difference between the reported application rates in DCSS in the general/specialized, teaching/research, nonteaching/research hospitals with the exception of pharmacies and radiology departments. They reported availability of a written QA plan significantly more often in research hospitals. Nearly all QA strategies were reported to be applied significantly more often in the DCSS of Social Security Organization (SSO) and private-for-profit hospitals than in governmental hospitals. There is still room for strengthening the managerial cycle of QA systems and accountability in the DCSS in Iranian hospitals. Getting feedback, change and learning through application of specific QA strategies (eg, external/internal audits) can be improved. Both the effectiveness of QA strategies in practice, and the application of

  11. Application of Quality Assurance Strategies in Diagnostics and Clinical Support Services in Iranian Hospitals

    Directory of Open Access Journals (Sweden)

    Asgar Aghaei Hashjin

    2015-10-01

    Full Text Available Background Iran has a widespread diagnostics and clinical support services (DCSS network that plays a crucial role in providing diagnostic and clinical support services to both inpatient and outpatient care. However, very little is known on the application of quality assurance (QA policies in DCSS units. This study explores the extent of application of eleven QA strategies in DCSS units within Iranian hospitals and its association with hospital characteristics. Methods A descriptive cross-sectional study was conducted in 2009/2010. Data were collected from 554 DCSS units among 84 hospitals. Results The average reported application rate for the QA strategies ranged from 57%-94% in the DCSS units. Most frequently reported were checking drugs expiration dates (94%, pharmacopoeia availability (92%, equipment calibration (87% and identifying responsibilities (86%. Least reported was external auditing of the DCSS (57%. The clinical chemistry and microbiology laboratories (84%, pharmacies, blood bank services (83% reported highest average application rates across all questioned QA strategies. Lowest application rates were reported in human tissue banks (50%. There was no significant difference between the reported application rates in DCSS in the general/specialized, teaching/research, nonteaching/research hospitals with the exception of pharmacies and radiology departments. They reported availability of a written QA plan significantly more often in research hospitals. Nearly all QA strategies were reported to be applied significantly more often in the DCSS of Social Security Organization (SSO and private-for-profit hospitals than in governmental hospitals. Conclusion There is still room for strengthening the managerial cycle of QA systems and accountability in the DCSS in Iranian hospitals. Getting feedback, change and learning through application of specific QA strategies (eg, external/internal audits can be improved. Both the effectiveness of QA

  12. Clinical cognition and diagnostic error: applications of a dual process model of reasoning.

    Science.gov (United States)

    Croskerry, Pat

    2009-09-01

    Both systemic and individual factors contribute to missed or delayed diagnoses. Among the multiple factors that impact clinical performance of the individual, the caliber of cognition is perhaps the most relevant and deserves our attention and understanding. In the last few decades, cognitive psychologists have gained substantial insights into the processes that underlie cognition, and a new, universal model of reasoning and decision making has emerged, Dual Process Theory. The theory has immediate application to medical decision making and provides an overall schema for understanding the variety of theoretical approaches that have been taken in the past. The model has important practical applications for decision making across the multiple domains of healthcare, and may be used as a template for teaching decision theory, as well as a platform for future research. Importantly, specific operating characteristics of the model explain how diagnostic failure occurs.

  13. Non invasive radiofrequency diagnostics of cancer. The Bioscanner — Trimprob technology and clinical applications

    Science.gov (United States)

    Vedruccio, Clarbruno; Ricci Vedruccio, Carla

    2011-12-01

    A new paper by Pokorny, Vedruccio, Cifra, Kucera, titled Cancer physics: Diagnostics based on damped cellular elasto-electrical vibrations in microtubules, recently available on Eur. Biophys. J., discloses the mechanism of active grown cancer tissues interaction with a Non- Linear Resonance Interaction (NLRI) Bioscanner Trimprob diagnostic device that is certified and ready to be used to investigate suspected cases of disease and cancer. This technology spreads early capabilities of cancer detection by means of low level radiofrequency oscillations in UHF band. The system is based on an unique and extremely innovative non- linear radiofrequency oscillator working on 462-465 MHz plus the harmonics. The diseased tissues suspected of cancer, are irradiated by means of a handy probe near field emission, while a spectrum analyzer placed in the far field detects by means of a small antenna, the oscillator interaction within the tissues. The Bioscanner is characterized by a high dynamic range, in the order of 30 or more decibel, and is useful for detection of small cancer agglomerates, if used by a well trained operator. At the resonance, the free running oscillator locks-in on the specific interaction frequency, in a sharp frequency window centered on 462 MHz; the resulting effect is evidenced by a deep decrease of the 462 MHz spectral line propagation in the far field around the oscillator probe. The NLRI provides a selective characterization, like a sort of a electronic biopsy response of biologic tissues in support of modern imaging diagnostics. Further to existing literature describing methods for cancer detections by means of electromagnetic fields this paper shows this innovative in vivo medical diagnostic equipment and some clinical applications.

  14. Non invasive radiofrequency diagnostics of cancer. The Bioscanner — Trimprob technology and clinical applications

    International Nuclear Information System (INIS)

    Vedruccio, Clarbruno; Vedruccio, Carla Ricci

    2011-01-01

    A new paper by Pokorny, Vedruccio, Cifra, Kucera, titled Cancer physics: Diagnostics based on damped cellular elasto-electrical vibrations in microtubules, recently available on Eur. Biophys. J., discloses the mechanism of active grown cancer tissues interaction with a Non- Linear Resonance Interaction (NLRI) Bioscanner Trimprob diagnostic device that is certified and ready to be used to investigate suspected cases of disease and cancer. This technology spreads early capabilities of cancer detection by means of low level radiofrequency oscillations in UHF band. The system is based on an unique and extremely innovative non- linear radiofrequency oscillator working on 462-465 MHz plus the harmonics. The diseased tissues suspected of cancer, are irradiated by means of a handy probe near field emission, while a spectrum analyzer placed in the far field detects by means of a small antenna, the oscillator interaction within the tissues. The Bioscanner is characterized by a high dynamic range, in the order of 30 or more decibel, and is useful for detection of small cancer agglomerates, if used by a well trained operator. At the resonance, the free running oscillator locks-in on the specific interaction frequency, in a sharp frequency window centered on 462 MHz; the resulting effect is evidenced by a deep decrease of the 462 MHz spectral line propagation in the far field around the oscillator probe. The NLRI provides a selective characterization, like a sort of a electronic biopsy response of biologic tissues in support of modern imaging diagnostics. Further to existing literature describing methods for cancer detections by means of electromagnetic fields this paper shows this innovative in vivo medical diagnostic equipment and some clinical applications.

  15. Clinical application and evaluation of the diagnostic significance of NMR-tomography

    International Nuclear Information System (INIS)

    Bielke, G.; Higer, P.

    1987-01-01

    Aim of the project was the clinical application and evaluation of the diagnostic significance of NMR-tomography. About 3 000 patients have been examined especially with diseases of the brain. In 75% of all cases pathological findings could be detected. A subgroup of these patients was used for comprehensive studies with regard to tissue characterization based on the calculation of relaxation time parameters. With methods of image processing and classification techniques we tried to get a clear correlation between combined NMR-parameters and human tissue types. The results show that this procedure is able to improve the detectibility and the association to finding groups and tumorgradings in certain cases. (orig./ECB) With 134 refs., 17 tabs., 86 figs [de

  16. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications

    DEFF Research Database (Denmark)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond

    2014-01-01

    and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I...

  17. Development and clinical applications of a small peptide as a radiolabeled in vivo diagnostic probe

    International Nuclear Information System (INIS)

    Reubi, J.C.; Lamberts, S.W.; Krenning, E.

    1995-01-01

    Several dozens of small peptides, widely distributed in the human body, highly potent and important regulators of biological processes in numerous tissues, have been identified in the past several years. One of those, somatostatin, the first of such peptides used in the nuclear medicine field, has been developed as an in vivo labeled diagnostic probe for a variety of pathologies. Basic knowledge on somatostatin, somatostatin receptors and somatostatin target tissues as well as on the clinical implications of this diagnostic tool are briefly reviewed. (authors). 9 refs., 3 figs

  18. Indications, applications and future prospects of diagnostic examinations in clinical cardiology

    International Nuclear Information System (INIS)

    Sugishita, Yasuro; Koseki, Susumu; Matsuda, Mitsuo

    1982-01-01

    Nowadays there are various kinds of diagnostic examinations in the field of clinical cardiology. In this field, information concerning structure, dimension (hypertrophy and dilatation) and cardiac function is essentially imporant. For the diagnosis of valvular and congenital heart diseases and of cardiomyopathy, ultrasonic examinations are more useful; for ischemic heart disease, nuclear medicine is superior. Angiocardiography provides us much information but it is invasive. A combination of an exercise-test with the examinations mentioned above is useful for the detection of left ventricular and coronary reserves. The determinants of left ventricular reserve, being related to the prognosis of the patients, can be analyzed by exercise echocardiography. Exercise echocardiography can reveal instantaneous changes in myocardial ischemia during exercise. Regional and global left ventricular performances revealed by exercise radionuclide angiocardiography can lead us to a new interpretation of an exercise ECG. (author)

  19. Application of Massively Parallel Sequencing in the Clinical Diagnostic Testing of Inherited Cardiac Conditions

    Directory of Open Access Journals (Sweden)

    Ivone U. S. Leong

    2014-06-01

    Full Text Available Sudden cardiac death in people between the ages of 1–40 years is a devastating event and is frequently caused by several heritable cardiac disorders. These disorders include cardiac ion channelopathies, such as long QT syndrome, catecholaminergic polymorphic ventricular tachycardia and Brugada syndrome and cardiomyopathies, such as hypertrophic cardiomyopathy and arrhythmogenic right ventricular cardiomyopathy. Through careful molecular genetic evaluation of DNA from sudden death victims, the causative gene mutation can be uncovered, and the rest of the family can be screened and preventative measures implemented in at-risk individuals. The current screening approach in most diagnostic laboratories uses Sanger-based sequencing; however, this method is time consuming and labour intensive. The development of massively parallel sequencing has made it possible to produce millions of sequence reads simultaneously and is potentially an ideal approach to screen for mutations in genes that are associated with sudden cardiac death. This approach offers mutation screening at reduced cost and turnaround time. Here, we will review the current commercially available enrichment kits, massively parallel sequencing (MPS platforms, downstream data analysis and its application to sudden cardiac death in a diagnostic environment.

  20. Biofluid infrared spectro-diagnostics: pre-analytical considerations for clinical applications.

    Science.gov (United States)

    Lovergne, L; Bouzy, P; Untereiner, V; Garnotel, R; Baker, M J; Thiéfin, G; Sockalingum, G D

    2016-06-23

    Several proof-of-concept studies on the vibrational spectroscopy of biofluids have demonstrated that the methodology has promising potential as a clinical diagnostic tool. However, these studies also show that there is a lack of a standardised protocol in sample handling and preparation prior to spectroscopic analysis. One of the most important sources of analytical errors is the pre-analytical phase. For the technique to be translated into clinics, it is clear that a very strict protocol needs to be established for such biological samples. This study focuses on some of the aspects of the pre-analytical phase in the development of the high-throughput Fourier Transform Infrared (FTIR) spectroscopy of some of the most common biofluids such as serum, plasma and bile. Pre-analytical considerations that can impact either the samples (solvents, anti-coagulants, freeze-thaw cycles…) and/or spectroscopic analysis (sample preparation such as drying, deposit methods, volumes, substrates, operators dependence…) and consequently the quality and the reproducibility of spectral data will be discussed in this report.

  1. Radiation exposure and image quality in X-ray diagnostic radiology. Physical principles and clinical applications. 2. ed.

    International Nuclear Information System (INIS)

    Saebel, Manfred; Aichinger, Horst; Dierker, Joachim; Joite-Barfuss, Sigrid

    2012-01-01

    Diagnostic X-rays are the largest contributor to radiation exposure to the general population, and protecting the patient from radiation damage is a major aim of modern health policy. Once the decision has been taken to use ionising radiation for imaging in a particular patient, it is necessary to optimize the image acquisition process taking into account the diagnostic quality of the images and the radiation dose to the patient. Both image quality and radiation dose are affected by a number of parameters, knowledge of which permits scientifically based decision making. The authors of this second edition of Radiation Exposure and Image Quality in X-ray Diagnostic Radiology have spent many years studying the optimization of radiological imaging. In this book they present in detail the basic physical principles of diagnostic radiology and their application to clinical problems. Particular attention is devoted to evaluation of the dose to the patient, the influence of scattered radiation on image quality, the use of antiscatter grids, and optimization of image quality and dose. The final section is a supplement containing tables of data and graphical depictions of X-ray spectra, interaction coefficients, characteristics of X-ray beams, and other aspects relevant to patient dose calculations. In addition, a complementary CD-ROM contains a user-friendly Excel file database covering these aspects that can be used in the reader's own programs. Since the first edition, the text, figures, tables, and references have all been thoroughly updated, and more detailed attention is now paid to image quality and radiation exposure when using digital imaging and computed tomography. This book will be an invaluable aid to medical physicists when performing calculations relating to patient dose and image quality, and will also prove useful for diagnostic radiologists and engineers. (orig.)

  2. Radiation exposure and image quality in x-Ray diagnostic radiology physical principles and clinical applications

    CERN Document Server

    Aichinger, Horst; Joite-Barfuß, Sigrid; Säbel, Manfred

    2012-01-01

    The largest contribution to radiation exposure to the population as a whole arises from diagnostic X-rays. Protecting the patient from radiation is a major aim of modern health policy, and an understanding of the relationship between radiation dose and image quality is of pivotal importance in optimising medical diagnostic radiology. In this volume the data provided for exploring these concerns are partly based on X-ray spectra, measured on diagnostic X-ray tube assemblies, and are supplemented by the results of measurements on phantoms and simulation calculations.

  3. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications

    DEFF Research Database (Denmark)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond

    2014-01-01

    AIMS: The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥...... comprehensive instruments augment short and simple screening instruments for Axis I and Axis II. These validated instruments allow for identification of patients with a range of simple to complex TMD presentations....

  4. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications

    DEFF Research Database (Denmark)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond

    2014-01-01

    of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. RESULTS: The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting...

  5. A modified artificial immune system based pattern recognition approach -- an application to clinic diagnostics

    Science.gov (United States)

    Zhao, Weixiang; Davis, Cristina E.

    2011-01-01

    study 2 are 0.49% (AIS-RBFPLS) and 6.61% (AIS-kNN); and (3) the proposed AIS-RBFPLS classification approaches also yielded better diagnosis results than two classical neural network approaches of BPNN and Ortho-RBF network. Conclusion In summary, this paper proposed a new machine learning method for complex systems by integrating the AIS system with RBFPLS. This new method demonstrates its satisfactory effect on classification accuracy for clinical diagnosis, and also indicates its wide potential applications to other diagnosis and detection problems. PMID:21515033

  6. Application of MALDI-TOF mass spectrometry in clinical diagnostic microbiology.

    Science.gov (United States)

    De Carolis, Elena; Vella, Antonietta; Vaccaro, Luisa; Torelli, Riccardo; Spanu, Teresa; Fiori, Barbara; Posteraro, Brunella; Sanguinetti, Maurizio

    2014-09-12

    Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently emerged as a powerful technique for identification of microorganisms, changing the workflow of well-established laboratories so that its impact on microbiological diagnostics has been unparalleled. In comparison with conventional identification methods that rely on biochemical tests and require long incubation procedures, MALDI-TOF MS has the advantage of identifying bacteria and fungi directly from colonies grown on culture plates in a few minutes and with simple procedures. Numerous studies on different systems available demonstrate the reliability and accuracy of the method, and new frontiers have been explored besides microbial species level identification, such as direct identification of pathogens from positive blood cultures, subtyping, and drug susceptibility detection.

  7. The rare and undiagnosed diseases diagnostic service - application of massively parallel sequencing in a state-wide clinical service.

    Science.gov (United States)

    Baynam, Gareth; Pachter, Nicholas; McKenzie, Fiona; Townshend, Sharon; Slee, Jennie; Kiraly-Borri, Cathy; Vasudevan, Anand; Hawkins, Anne; Broley, Stephanie; Schofield, Lyn; Verhoef, Hedwig; Walker, Caroline E; Molster, Caron; Blackwell, Jenefer M; Jamieson, Sarra; Tang, Dave; Lassmann, Timo; Mina, Kym; Beilby, John; Davis, Mark; Laing, Nigel; Murphy, Lesley; Weeramanthri, Tarun; Dawkins, Hugh; Goldblatt, Jack

    2016-06-11

    The Rare and Undiagnosed Diseases Diagnostic Service (RUDDS) refers to a genomic diagnostic platform operating within the Western Australian Government clinical services delivered through Genetic Services of Western Australia (GSWA). GSWA has provided a state-wide service for clinical genetic care for 28 years and it serves a population of 2.5 million people across a geographical area of 2.5milion Km(2). Within this context, GSWA has established a clinically integrated genomic diagnostic platform in partnership with other public health system managers and service providers, including but not limited to the Office of Population Health Genomics, Diagnostic Genomics (PathWest Laboratories) and with executive level support from the Department of Health. Herein we describe report presents the components of this service that are most relevant to the heterogeneity of paediatric clinical genetic care. Briefly the platform : i) offers multiple options including non-genetic testing; monogenic and genomic (targeted in silico filtered and whole exome) analysis; and matchmaking; ii) is delivered in a patient-centric manner that is resonant with the patient journey, it has multiple points for entry, exit and re-entry to allow people access to information they can use, when they want to receive it; iii) is synchronous with precision phenotyping methods; iv) captures new knowledge, including multiple expert review; v) is integrated with current translational genomic research activities and best practice; and vi) is designed for flexibility for interactive generation of, and integration with, clinical research for diagnostics, community engagement, policy and models of care. The RUDDS has been established as part of routine clinical genetic services and is thus sustainable, equitably managed and seeks to translate new knowledge into efficient diagnostics and improved health for the whole community.

  8. [Special application of matrix-assisted laser desorption ionization time-of-flight mass spectrometry in clinical microbiological diagnostics].

    Science.gov (United States)

    Nagy, Erzsébet; Abrók, Marianna; Bartha, Noémi; Bereczki, László; Juhász, Emese; Kardos, Gábor; Kristóf, Katalin; Miszti, Cecilia; Urbán, Edit

    2014-09-21

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry as a new possibility for rapid identification of bacteria and fungi revolutionized the clinical microbiological diagnostics. It has an extreme importance in the routine microbiological laboratories, as identification of the pathogenic species rapidly will influence antibiotic selection before the final determination of antibiotic resistance of the isolate. The classical methods for identification of bacteria or fungi, based on biochemical tests, are influenced by many environmental factors. The matrix-assisted laser desorption ionization time-of-flight mass spectrometry is a rapid method which is able to identify a great variety of the isolated bacteria and fungi based on the composition of conserved ribosomal proteins. Recently several other applications of the method have also been investigated such as direct identification of pathogens from the positive blood cultures. There are possibilities to identify bacteria from the urine samples in urinary tract infection or from other sterile body fluids. Using selective enrichment broth Salmonella sp from the stool samples can be identified more rapidly, too. The extended spectrum beta-lactamase or carbapenemase production of the isolated bacteria can be also detected by this method helping the antibiotic selection in some cases. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry based methods are suitable to investigate changes in deoxyribonucleic acid or ribonucleic acid, to carry out rapid antibiotic resistance determination or other proteomic analysis. The aim of this paper is to give an overview about present possibilities of using this technique in the clinical microbiological routine procedures.

  9. Angiography - interventional diagnostic applications

    International Nuclear Information System (INIS)

    Schild, H.

    1994-01-01

    The angiography system is very different from the other systems used in diagnostic radiology. The invasivity of angiography requires special, high standards in theoretical and practical training and experience both of beginners and experienced personnel. This textbook fully meets the demand for in-depth and exhaustive information, as it presents: - The fundamentals and techniques of angiography, the vascular anatomy, and many hints and tips of great help in practice. - A comprehensive survey of diagnostic problems and examination approaches, including neuro-angiography, with 221 reproductions of original angiographs, and additional schematic representations. - A special chapter devoted to indication and relevant techniques for the major vascular interventional examinations. - A great number of tables explain at a glance standard examination techniques, indications and diagnostic criteria. (orig./CB) [de

  10. Dengue score as a diagnostic predictor for pleural effusion and/or ascites: external validation and clinical application.

    Science.gov (United States)

    Suwarto, Suhendro; Hidayat, Mohammad Jauharsyah; Widjaya, Bing

    2018-02-23

    The Dengue Score is a model for predicting pleural effusion and/or ascites and uses the hematocrit (Hct), albumin concentration, platelet count and aspartate aminotransferase (AST) ratio as independent variables. As this metric has not been validated, we conducted a study to validate the Dengue Score and assess its clinical application. A retrospective study was performed at a private hospital in Jakarta, Indonesia. Patients with dengue infection hospitalized from January 2011 through March 2016 were included. The Dengue Score was calculated using four parameters: Hct increase≥15.1%, serum albumin≤3.49 mg/dL, platelet count≤49,500/μL and AST ratio ≥ 2.51. Each parameter was scored as 1 if present and 0 if absent. To validate the Dengue Score, goodness-of-fit was used to assess calibration, and the area under the receiver operating characteristic curve (AROC) was used to assess discrimination. Associations between clinical parameters and Dengue Score groups were determined by bivariate analysis. A total of 207 patients were included in this study. The calibration of the Dengue Score was acceptable (Hosmer-Lemeshow test, p = 0.11), and the score's discriminative ability was good (AROC = 0.88 (95% CI: 0.83-0.92)). At a cutoff of ≥2, the Dengue Score had a positive predictive value (PPV) of 79.03% and a negative predictive value (NPV) of 90.36% for the diagnostic prediction of pleural effusion and/or ascites. Compared with the Dengue Score ≤ 1 group, the Dengue Score = 2 group was significantly associated with hemoconcentration> 20% (p = 0.029), severe thrombocytopenia (p = 0.029), and increased length of hospital stay (p = 0.003). Compared with the Dengue Score = 2 group, the Dengue Score ≥ 3 group was significantly associated with hemoconcentration> 20% (p = 0.001), severe thrombocytopenia (p = 0.024), severe dengue (p = 0.039), and increased length of hospital stay (p = 0.011). The Dengue Score performed well and can

  11. CpG Methylation Analysis—Current Status of Clinical Assays and Potential Applications in Molecular Diagnostics

    Science.gov (United States)

    Sepulveda, Antonia R.; Jones, Dan; Ogino, Shuji; Samowitz, Wade; Gulley, Margaret L.; Edwards, Robin; Levenson, Victor; Pratt, Victoria M.; Yang, Bin; Nafa, Khedoudja; Yan, Liying; Vitazka, Patrick

    2009-01-01

    Methylation of CpG islands in gene promoter regions is a major molecular mechanism of gene silencing and underlies both cancer development and progression. In molecular oncology, testing for the CpG methylation of tissue DNA has emerged as a clinically useful tool for tumor detection, outcome prediction, and treatment selection, as well as for assessing the efficacy of treatment with the use of demethylating agents and monitoring for tumor recurrence. In addition, because CpG methylation occurs early in pre-neoplastic tissues, methylation tests may be useful as markers of cancer risk in patients with either infectious or inflammatory conditions. The Methylation Working Group of the Clinical Practice Committee of the Association of Molecular Pathology has reviewed the current state of clinical testing in this area. We report here our summary of both the advantages and disadvantages of various methods, as well as the needs for standardization and reporting. We then conclude by summarizing the most promising areas for future clinical testing in cancer molecular diagnostics. PMID:19541921

  12. Clinical dosimetry in diagnostic and interventional radiology

    International Nuclear Information System (INIS)

    Dimcheva, M.; Sergieva, S.; Jovanovska, A.

    2012-01-01

    Full text: Introduction: Diagnostic and interventional procedures involving x-rays are the most significant contributor to total population dose form man made sources of ionizing radiation. Purpose and aim: X-ray imaging generally covers a diverse range of examination types, many of which are increasing in frequency and technical complexity. Materials and methods: The European Directives 96/29 and 97/43 EURATOM stress the importance of accurate dosimetry and require calibration of all measuring equipment related to application of ionizing radiation in medicine. Results: The paper gives and overview of current system of dosimetry of ionizing radiations that is relevant for metrology and clinical applications. It also reflects recently achieved international harmonization in the field promoted by International Atomic Energy Agency (IAEA). Discussion: Objectives of clinical dose measurements in diagnostic and interventional radiology are multiple, as assessment of equipment performance, or assessment of risk emerging from use of ionizing radiation Conclusion: Therefore, from the clinical point of view, the requirements for dosimeters and procedures to assess dose to standard dosimetry phantoms and patients in clinical diverse modalities, as computed tomography are presented

  13. The applicability of real-time PCR in the diagnostic of cutaneous leishmaniasis and parasite quantification for clinical management: Current status and perspectives.

    Science.gov (United States)

    Moreira, Otacilio C; Yadon, Zaida E; Cupolillo, Elisa

    2017-09-29

    Cutaneous leishmaniasis (CL) is spread worldwide and is the most common manifestation of leishmaniasis. Diagnosis is performed by combining clinical and epidemiological features, and through the detection of Leishmania parasites (or DNA) in tissue specimens or trough parasite isolation in culture medium. Diagnosis of CL is challenging, reflecting the pleomorphic clinical manifestations of this disease. Skin lesions vary in severity, clinical appearance, and duration, and in some cases, they can be indistinguishable from lesions related to other diseases. Over the past few decades, PCR-based methods, including real-time PCR assays, have been developed for Leishmania detection, quantification and species identification, improving the molecular diagnosis of CL. This review provides an overview of many real-time PCR methods reported for the diagnostic evaluation of CL and some recommendations for the application of these methods for quantification purposes for clinical management and epidemiological studies. Furthermore, the use of real-time PCR for Leishmania species identification is also presented. The advantages of real-time PCR protocols are numerous, including increased sensitivity and specificity and simpler standardization of diagnostic procedures. However, despite the numerous assays described, there is still no consensus regarding the methods employed. Furthermore, the analytical and clinical validation of CL molecular diagnosis has not followed international guidelines so far. A consensus methodology comprising a DNA extraction protocol with an exogenous quality control and an internal reference to normalize parasite load is still needed. In addition, the analytical and clinical performance of any consensus methodology must be accurately assessed. This review shows that a standardization initiative is essential to guide researchers and clinical laboratories towards the achievement of a robust and reproducible methodology, which will permit further evaluation

  14. Comparison Of Clinical, Parasitological And Serological Diagnostic ...

    African Journals Online (AJOL)

    Comparison Of Clinical, Parasitological And Serological Diagnostic Methods For The Definitive ... Consideringthe relative significance of these methods in the diagnosis of onchocerciasis, we ... http://dx.doi.org/10.4314/ari.v1i3.40835.

  15. Thymic hyperplasia - clinical course and imaging diagnostic

    International Nuclear Information System (INIS)

    Drebov, R.; Panov, M.; Totev, M.; Deliverski, T.; Tcandev, I.; Velkovski, I.

    2006-01-01

    The real thymic hyperplasia is benign disease sometimes simulating malignant tumours. The aim of this study is to analyse the clinical symptoms of real thymic hyperplasia and the results from imaging diagnostic based on our clinical material. Clinical material include 27 children, aged from two months to 15 years, admitted in department of thoracic surgery, for a period of 20 years (1985 - 2004). We retrospectively analyze the clinical signs and results from X-ray investigation, CT (Siemens Somatom DRG and Philips Secura) and echocardiography (Acuson TX, 5 and 7 MHz). We discuss the diagnostic value of different methods as well as typical and atypical findings. (authors)

  16. Clinical application of lower extremity CTA and lower extremity perfusion CT as a method of diagnostic for lower extremity atherosclerotic obliterans

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Il Bong; Dong, Kyung Rae [Dept. Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Goo, Eun Hoe [Dept. Radiological Science, Cheongju University, Cheongju (Korea, Republic of)

    2016-11-15

    The purpose of this study was to assess clinical application of lower extremity CTA and lower extremity perfusion CT as a method of diagnostic for lower extremity atherosclerotic obliterans. From January to July 2016, 30 patients (mean age, 68) were studied with lower extremity CTA and lower extremity perfusion CT. 128 channel multi-detector row CT scans were acquired with a CT scanner (SOMATOM Definition Flash, Siemens medical solution, Germany) of lower extremity perfusion CT and lower extremity CTA. Acquired images were reconstructed with 3D workstation (Leonardo, Siemens, Germany). Site of lower extremity arterial occlusive and stenosis lesions were detected superficial femoral artery 36.6%, popliteal artery 23.4%, external iliac artery 16.7%, common femoral artery 13.3%, peroneal artery 10%. The mean total DLP comparison of lower extremity perfusion CT and lower extremity CTA, 650 mGy-cm and 675 mGy-cm, respectively. Lower extremity perfusion CT and lower extremity CTA were realized that were never be two examination that were exactly the same legions. Future through the development of lower extremity perfusion CT soft ware programs suggest possible clinical applications.

  17. Clinical PET application

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Moo; Hong, Song W.; Choi, Chang W.; Yang, Seong Dae [Korea Cancer Center Hospital, Seoul (Korea)

    1997-12-01

    PET gives various methabolic images, and is very important, new diagnostic modality in clinical oncology. In Korea Cancer Center Hospital, PET is installed as a research tool of long-mid-term atomic research project. For the efficient use of PET for clinical and research projects, income from the patients should be managed to get the raw material, equipment, manpower, and also for the clinical PET research. 1. Support the clinical application of PET in oncology. 2. Budgetary management of income, costs for raw material, equipment, manpower, and the clinical PET research project. In this year, 250 cases of PET images were obtained, which resulted total income of 180,000,000 won. 50,000,000 won was deposited for the 1998 PET clinical research. Second year PET clinical research should be managed under unified project. Increased demand for {sup 18}FDG in and outside KCCH need more than 2 times production of {sup 18}FDG in a day purchase of HPLC pump and {sup 68}Ga pin source which was delayed due to economic crisis, should be done early in 1998. (author). 2 figs., 3 tabs.

  18. Diagnostic applications of nail clippings.

    Science.gov (United States)

    Stephen, Sasha; Tosti, Antonella; Rubin, Adam I

    2015-04-01

    "Nail clipping is a simple technique for diagnosis of several nail unit dermatoses. This article summarizes the practical approach, utility, and histologic findings of a nail clipping in evaluation of onychomycosis, nail unit psoriasis, onychomatricoma, subungual hematoma, melanonychia, and nail cosmetics, and the forensic applications of this easily obtained specimen. It reviews important considerations in optimizing specimen collection, processing methods, and efficacy of special stains in several clinical contexts. Readers will develop a greater understanding and ease of application of this indispensable procedure in assessing nail unit dermatoses." Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Serumferritin - diagnostic relevance and clinical usefulness

    Energy Technology Data Exchange (ETDEWEB)

    Linkesch, W [Vienna Univ. (Austria). 2. Medizinische Klinik

    1984-01-01

    The introduction of a WHO Standard for serumferritin effected a standardisation of different methods, improving quality and security for clinical routine diagnostic purposes. Therefore the clinical evaluation of serumferritin gained even more importance. For evaluation of iron stores of children, pregnant women, population studies, patients on hemodialysis or patients with rheumatoid arthritis low serumferritin values give safe results. In addition serumferritin is of clinical usefulness in monitoring therapy of both iron deficiency and iron overload. Evaluating a single serumferritin value one should consider the total clinical situation of the patient. As some tumors can produce and secrete serumferritin, e.g. acute myeloblastic leukemia, germ cell tumors, malignant melanoma, serumferritin might be helpful in monitoring the malignant disease. The ongoing characterization of tissue isoferritin, especially acidic isoferritin, may eventually lead to a clinically significant diagnostic marker of neoplasia.

  20. Serumferritin - diagnostic relevance and clinical usefulness

    International Nuclear Information System (INIS)

    Linkesch, W.

    1984-01-01

    The introduction of a WHO Standard for serumferritin effected a standardisation of different methods, improving quality and security for clinical routine diagnostic purposes. Therefore the clinical evaluation of serumferritin gained even more importance. For evaluation of iron stores of children, pregnant women, population studies, patients on hemodialysis or patients with rheumatoid arthritis low serumferritin values give safe results. In addition serumferritin is of clinical usefulness in monitoring therapy of both iron deficiency and iron overload. Evaluating a single serumferritin value on should consider the total clinical situation of the patient. As some tumors can produce and secrete serumferritin, e. g. acute myeloblastic leukemia, germ cell tumors, malignant melanoma, serumferritin might be helpful in monitoring the malignant disease. The ongoing characterization of tissue isoferritin, especially acidic isoferritin, may eventually lead to a clinically significant diagnostic marker of neoplasia. (Author)

  1. Advanced microarray technologies for clinical diagnostics

    NARCIS (Netherlands)

    Pierik, Anke

    2011-01-01

    DNA microarrays become increasingly important in the field of clinical diagnostics. These microarrays, also called DNA chips, are small solid substrates, typically having a maximum surface area of a few cm2, onto which many spots are arrayed in a pre-determined pattern. Each of these spots contains

  2. Clinical application of nuclear medical diagnostic method for adaptation deciion of treatment for circulatory disease and evaluation of its efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Yoshio; Hayashida, Kohei; Fukuchi, Kazuki [National Cardiovascular Center, Suita, Osaka (Japan)

    2000-02-01

    In this study, the conditions of patients to which cerebral revascularization through anastomosis of internal and external carotid arteries is applicable were investigated. In the first part, classification of the degree of cerebrovascular disease was attempted using positron emission tomography (PET) and in the second, cerebral blood circulation was evaluated using cerebral SPECT to consider in respect of advisability of the revascularization surgery. Since cerebral ischemia tends to be induced by enhancement of cerebral oxygen uptake, cerebral revascularization was thought to be restricted to the patients with cerebrovascular disease in stage 2. So, cerebral blood flow, cerebral blood volume and cerebral oxygen metabolism were compared among the patients in stage 1 and stage 2, and the normal control. The blood flow was decreased with the severity of disease and lowest in the patients of stage 2. There were significant differences in the oxygen metabolism and blood volume between the patient stage 1 and the control. The cerebral blood flow in patient in stage 2 was decreased to a level below the self-control range, leading to an increase in the cerebral oxygen uptake. Therefore, it was concluded that the severity of cerebrovascular disease could be estimated with cerebrocirculation index and vasodilation ability determined by cerebral SPECT. Patients of which cerebral blood flow is decreased by more than 28.0% can be regarded as the patient in stage 2. When cerebral blood volume determined by IMP-ARG method and PET method and was compared, underestimation was 34.5% for plane phantom and 11% for cranial pseudo phantom. Further classification would be made on the basis of vascular response under the conditions of Diamox loading and it was concluded that cases of which decrease in cerebral blood flow is 10% or less were applicable to cerebral revascularization. (M.N.)

  3. Prevalence and Clinical Correlates of Sarcopenia in Community-Dwelling Older People: Application of the EWGSOP Definition and Diagnostic Algorithm

    Science.gov (United States)

    2014-01-01

    Background. Muscle impairment is a common condition in older people and a powerful risk factor for disability and mortality. The aim of this study was to apply the European Working Group on Sarcopenia in Older People criteria to estimate the prevalence and investigate the clinical correlates of sarcopenia, in a sample of Italian community-dwelling older people. Methods. Cross-sectional analysis of 730 participants (74% aged 65 years and older) enrolled in the InCHIANTI study. Sarcopenia was defined according to the European Working Group on Sarcopenia in Older People criteria using bioimpedance analysis for muscle mass assessment. Logistic regression analysis was used to identify the factors independently associated with sarcopenia. Results. Sarcopenia defined by the European Working Group on Sarcopenia in Older People criteria increased steeply with age (p Nutritional intake, physical activity, and level of comorbidity were not associated with sarcopenia. Conclusions. Sarcopenia identified by the European Working Group on Sarcopenia in Older People criteria is a relatively common condition in Italian octogenarians, and its prevalence increases with aging. Correlates of sarcopenia identified in this study might suggest new approaches for prevention and treatment of sarcopenia. PMID:24085400

  4. Clinical and diagnostic aspects of lymphedema.

    Science.gov (United States)

    Keo, Hong H; Gretener, Silvia B; Staub, Daniel

    2017-07-01

    Lymphedema is a chronic, progressive, and common but often unrecognized condition. The diagnosis of lymphatic disease on clinical grounds alone remains a challenge. Without proper diagnosis, therapy is often delayed, allowing disease progression. There is a need for a practical diagnostic algorithm and its imaging technique to guide clinical decision-making. The aim of this topical review is to provide a practical approach for assessing patients with suspected lymphedema and to give a critical appraisal of currently available imaging modalities that are applied in clinical practice to diagnose and map lymphatic disease.

  5. Clinical application of optical coherence tomography in combination with functional diagnostics: advantages and limitations for diagnosis and assessment of therapy outcome in central serous chorioretinopathy.

    Science.gov (United States)

    Schliesser, Joshua A; Gallimore, Gary; Kunjukunju, Nancy; Sabates, Nelson R; Koulen, Peter; Sabates, Felix N

    2014-01-01

    While identifying functional and structural parameters of the retina in central serous chorioretinopathy (CSCR) patients, this study investigated how an optical coherence tomography (OCT)-based diagnosis can be significantly supplemented with functional diagnostic tools and to what degree the determination of disease severity and therapy outcome can benefit from diagnostics complementary to OCT. CSCR patients were evaluated prospectively with microperimetry (MP) and spectral domain optical coherence tomography (SD-OCT) to determine retinal sensitivity function and retinal thickness as outcome measures along with measures of visual acuity (VA). Patients received clinical care that involved focal laser photocoagulation or pharmacotherapy targeting inflammation and neovascularization. Correlation of clinical parameters with a focus on functional parameters, VA, and mean retinal sensitivity, as well as on the structural parameter mean retinal thickness, showed that functional measures were similar in diagnostic power. A moderate correlation was found between OCT data and the standard functional assessment of VA; however, a strong correlation between OCT and MP data showed that diagnostic measures cannot always be used interchangeably, but that complementary use is of higher clinical value. The study indicates that integrating SD-OCT with MP provides a more complete diagnosis with high clinical relevance for complex, difficult to quantify diseases such as CSCR.

  6. Primary mammary tuberculosis: Clinical diagnostic dilemma

    Directory of Open Access Journals (Sweden)

    Sunder Goyal

    2015-09-01

    Conclusion: Breast Tuberculous is uncommon in countries where incidence of pulmonary and extrapulmonary tuberculosis is very high. It continues to pose a diagnostic challenge due to its rarity, atypical clinical features and non confirmatory radiological modalities. Unnecessary mastectomy can be avoided if we keep this rare but medically treatable condition on back of our mind. [Arch Clin Exp Surg 2015; 4(3.000: 153-156

  7. Clinical X-ray diagnostics. v. 2

    International Nuclear Information System (INIS)

    Baudisch, E.; Becker, T.

    1981-01-01

    Principles of the general procedure in radiographic examination are the subject of the introduction. Following anatomico-clinical preliminary notes and suggestions concerning radiographic examination methods and proceeding from normal findings of the bones and from the general radiographic symptomatology of skeletal diseases, developmental disturbances, system diseases, radiogenic injuries, aseptic necroses, metabolic osteopathies, damages, inflammations and tumors as well as less frequently occuring diseases are discussed. Their pathology, clinic, diagnostics, diagnosis and differential diagnosis, their therapy and prognosis are dealt with from the clinico-radiographical point of view. The diseases of the joints of the radiographically demonstrable diseases of the soft parts of the limbs are also treated

  8. Beyond Diagnostic Accuracy: The Clinical Utility of Diagnostic Tests

    NARCIS (Netherlands)

    Bossuyt, Patrick M. M.; Reitsma, Johannes B.; Linnet, Kristian; Moons, Karel G. M.

    2012-01-01

    Like any other medical technology or intervention, diagnostic tests should be thoroughly evaluated before their introduction into daily practice. Increasingly, decision makers, physicians, and other users of diagnostic tests request more than simple measures of a test's analytical or technical

  9. THE PROBLEMS OF EARLY CLINICAL DEFECTOLOGICAL DIAGNOSTICS

    Directory of Open Access Journals (Sweden)

    Aleksandar CORDIC

    1997-06-01

    Full Text Available Clinical defectological diagnostics, related to diagnostics of each individual's impairment of his cognitive and socializing abilities, has been applied in our country for a long time. Since it is a new area in the clinical defectological work and a new form of research in defectology, it poses a series of problems which have not been met so far. We shall to recognize some of them in this paper and to aim at their solution.This time we shall consider only the most prominent problems towards which we direct our interventions:· When does defectological diagnostics take part in diagnosis as treatment of impairments of the handicapped person? When does it function in the process of rehabilitation? For example, is working with a dyslexic child treatment or rehabilitation?· When does the early diagnostics reveal a problem arising from inappropriate intersection of different development courses, which can sometimes be solved without any particular treatment (early stuttering, various convulsions, and when does it reveal actual condition, such as oligophrenia or autism. Thereby we ask ourselves if early stimulative treatment of oligophrenic children or children with early childhood psychosis is treatment or rehabilitation.We tried to classify end explain the problems of diagnostics in the context of treatment and rehabilitation and to define the theoretical grounds for our standpoints.We wanted to point out the unity of the process of any impairment of the handicapped person from early childhood to the end of his life. Treatment and rehabilitation should be a united process and follow the course of development of early disorders which sometimes end up as handicaps, and sometimes, thanks to the treatment, may end up in successful socialization, for example, persons with impaired hearing or sight.We establish defectology as a complete theoretical standpoint and expert procedure which is parallel to and complementary with medicine. The only difference we

  10. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†.

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J; Haythornthwaite, Jennifer A; Hollender, Lars; Jensen, Rigmor; John, Mike T; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M; Nixdorf, Donald R; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M; Zakrzewska, Joanna; Dworkin, Samuel F

    2014-01-01

    The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project-the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0.98) and for one intra

  11. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L.; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J.; Haythornthwaite, Jennifer A.; Hollender, Lars; Jensen, Rigmor; John, Mike T.; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M.; Nixdorf, Donald R.; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M.; Zakrzewska, Joanna; Dworkin, Samuel F.

    2015-01-01

    Aims The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Methods Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project—the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. Results The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0

  12. Application of digital diagnostic impression, virtual planning, and computer-guided implant surgery for a CAD/CAM-fabricated, implant-supported fixed dental prosthesis: a clinical report.

    Science.gov (United States)

    Stapleton, Brandon M; Lin, Wei-Shao; Ntounis, Athanasios; Harris, Bryan T; Morton, Dean

    2014-09-01

    This clinical report demonstrated the use of an implant-supported fixed dental prosthesis fabricated with a contemporary digital approach. The digital diagnostic data acquisition was completed with a digital diagnostic impression with an intraoral scanner and cone-beam computed tomography with a prefabricated universal radiographic template to design a virtual prosthetically driven implant surgical plan. A surgical template fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) was used to perform computer-guided implant surgery. The definitive digital data were then used to design the definitive CAD/CAM-fabricated fixed dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Clinical application of S-Detect to breast masses on ultrasonography: A study evaluating the diagnostic performance and agreement with a dedicated breast radiologist

    International Nuclear Information System (INIS)

    Kim, Ki Wook; Kim, Eun Kyung; Yoon, Jung Hyun; Song, Mi Kyung

    2017-01-01

    The purpose of this study was to evaluate the diagnostic performance of S-Detect when applied to breast ultrasonography (US), and the agreement with an experienced radiologist specializing in breast imaging. From June to August 2015, 192 breast masses in 175 women were included. US features of the breast masses were retrospectively analyzed by a radiologist who specializes in breast imaging and S-Detect, according to the fourth edition of the American College of Radiology Breast Imaging Reporting and Data System lexicon and final assessment categories. Final assessments from S-Detect were in dichotomized form: possibly benign and possibly malignant. Kappa statistics were used to analyze the agreement between the radiologist and S-Detect. Diagnostic performance of the radiologist and S-Detect was calculated, including sensitivity, specificity, positive predictive value (PPV), negative predictive value, accuracy, and area under the receiving operator characteristics curve. Of the 192 breast masses, 72 (37.5%) were malignant, and 120 (62.5%) were benign. Benign masses among category 4a had higher rates of possibly benign assessment on S-Detect for the radiologist, 63.5% to 36.5%, respectively (P=0.797). When the cutoff was set at category 4a, the specificity, PPV, and accuracy was significantly higher in S-Detect compared to the radiologist (all P<0.05), with a higher area under the receiver operator characteristics curve of 0.725 compared to 0.653 (P=0.038). Moderate agreement (k=0.58) was seen in the final assessment between the radiologist and S-Detect. S-Detect may be used as an additional diagnostic tool to improve the specificity of breast US in clinical practice, and guide in decision making for breast masses detected on US

  14. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology

    International Nuclear Information System (INIS)

    2010-01-01

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  15. MDS clinical diagnostic criteria for Parkinson's disease in China.

    Science.gov (United States)

    Li, Jun; Jin, Miao; Wang, Li; Qin, Bin; Wang, Kang

    2017-03-01

    The Movement Disorder Society Clinical Diagnostic Criteria for Parkinson's disease (MDS-PD Criteria) was introduced by the Movement Disorder Society in 2015 for research purposes. However, its use for clinical diagnosis of Parkinson disease still needs further revision. This study compares the UK-Criteria versus MDS-PD Criteria in the clinical diagnosis of Parkinson disease referred to the China-Japan Friendship Hospital of Beijing, China. To compare the MDS-PD Criteria with the UK-Criteria and discuss the feasibility of the clinical application of MDS-PD Criteria as a general guide to clinical diagnosis of PD in Chinese PD patients. 150 patients of neurology clinic of China-Japan Friendship Hospital of Beijing were recruited in our research. They were divided into three groups: UK-Criteria group, MDS-PD Criteria group and a combined group of UK and MDS-PD Criteria. Clinical history was collected while physical and auxiliary examinations were done by a trained neurologist according to the corresponding criteria. An interrater reliability analysis using the Kappa statistic claimed substantial agreement (κ = 0.626) between the MDS-PD Criteria and the UK-Criteria. The differences between the diagnostic results of these two criteria were statistically significant by paired Chi-square test (p = 0.000). It was found that levodopa-induced dyskinesia had a good positive predictive value, while early bulbar impairment and inspiratory dysfunction presented a negative predictive value. The MDS-PD Criteria emphasize the importance of non-motor symptoms, keeping the motor symptoms as the core for the clinical diagnosis of PD, and establish categories of diagnosis features and levels of certainty which are more complete and organized to be used and replicated by non specialized physicians to evaluated patients with Parkinsonism. The higher sensitivity of MDS-PD Criteria compared with UK-Criteria is worth being widely used in clinical work.

  16. Application of diagnostic system for diesel engine

    International Nuclear Information System (INIS)

    Yoshinaga, Takeshi; Hayashi, Haruji; Usui, Hiromi; Tsuruzono, Atsuya; Matsuda, Takafumi

    2008-01-01

    The Japan Atomic Power Company (JAPC) began to implement Condition Based Maintenance (CBM) for rotating components (pumps, fans and electric motors) from 1999 and, also has begun to apply diesel engine diagnostic techniques at our three nuclear power plants since 2004. This paper provides a description of the CBM methods used for diesel engines in nuclear standby service, a summary of the procedures to introduce these diagnostic techniques to our nuclear power plants, and experience with the application of these methods to JAPC nuclear power plants. (author)

  17. Infectious myocarditis (Clinic, diagnostics, principles of treatment

    Directory of Open Access Journals (Sweden)

    Yu. P. Finogeev

    2016-01-01

    Full Text Available Infective myocarditis can be considered as a case of myocardial damage caused by different infectious agents. Traditionally discusses the questions of diagnostics and treatment infectious myocarditis. The paper has repeatedly stressed the difficulty of clinical diagnosis, and the laboriousness and economic costs of laboratory tests and additional researches. Endomyocardial biopsy findings remain the gold standard for unequivocally establishing the diagnosis. However, it is technically extremely invasive test and can be performed only in specialized cardiology centers. The paper analyzes in detail not only own materials, but also results of researches published in numerous domestic and foreign sources of literature. Publication of «Infectious myocarditis» is necessary due to the fact that patients with a diagnosis of «Myocarditis » account for 11% of all cardiovascular disease in the world. Article is timely and necessary for many professionals, senior students of medical universities.

  18. Clinical applications of contrast echocardiography

    International Nuclear Information System (INIS)

    Jorge, Leon Galindo

    2005-01-01

    The echocardiography is the technique more used for the diagnosis and pursuit of the cardiovascular illnesses; therefore, their diagnostic precision has acquired a vital importance in the handling of the patients with cardiovascular pathologies. However, with relative frequency, the diagnostic capacity of the echocardiography exam is diminished by limitations of the acoustic window, mainly in-patient with obesity, lung illnesses and alterations of the thoracic wall. This can be obviated with the use of the intra-esophagus echocardiography, although this it is a procedure semi-invasive and not very practical of carrying out in all the patients with problems of acoustic window. In this article the clinical applications are revised more common of the contrast echocardiography

  19. Nanoparticles for therapeutic and diagnostic applications

    OpenAIRE

    Chiu, Yin To

    2014-01-01

    Nanomedicine focuses on the development and engineering of novel and unique therapeutic and diagnostic agents that can overcome the challenges associated with using traditional modalities. Nanoparticles (NPs) in the size range between 1 and 1000 nm have many advantages for use in these applications, such as, low polydispersity, established characterization methodologies, and the ability to be loaded with therapeutics for diseases, conjugated to targeting ligands to enhance specificity, and co...

  20. Artificial intelligence applications to nuclear reactor diagnostics

    International Nuclear Information System (INIS)

    Lee, J.C.; Hassberger, J.A.; Wehe, D.K.

    1987-01-01

    The authors research into applications of artificial intelligence to nuclear reactor diagnostics involves three main areas. In the first area, the authors combine reactor simulation models and expert systems to diagnose the state of the plant. The second area examines ways in which the rule or knowledge base of an intelligent controller can be generated systematically from either fault trees or acquired plant data. Third, efforts are described to develop the capabilities to validate these techniques in a realistic reactor setting. The techniques are applicable to all reactor types, including fast reactors

  1. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for clinical and research applications: recommendations of the international RDC/TMD consortium network and orofacial pain special interest group

    NARCIS (Netherlands)

    Schiffman, E.; Ohrbach, R.; Truelove, E.; Look, J.; Anderson, G.; Goulet, J.P.; List, T.; Svensson, P.; Gonzalez, Y.; Lobbezoo, F.; Michelotti, A.; Brooks, S.L.; Ceusters, W.; Drangsholt, M.; Ettlin, D.; Gaul, C.; Goldberg, L.J.; Haythornthwaite, J.A.; Hollender, L.; Jensen, R.; John, M.T.; De Laat, A.; de Leeuw, R.; Maixner, W.; van der Meulen, M.; Murray, G.M.; Nixdorf, D.R.; Palla, S.; Petersson, A.; Pionchon, P.; Smith, B.; Visscher, C.M.; Zakrzewska, J.; Dworkin, S.F.

    2014-01-01

    AIMS: The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥

  2. Constructing diagnostic likelihood: clinical decisions using subjective versus statistical probability.

    Science.gov (United States)

    Kinnear, John; Jackson, Ruth

    2017-07-01

    Although physicians are highly trained in the application of evidence-based medicine, and are assumed to make rational decisions, there is evidence that their decision making is prone to biases. One of the biases that has been shown to affect accuracy of judgements is that of representativeness and base-rate neglect, where the saliency of a person's features leads to overestimation of their likelihood of belonging to a group. This results in the substitution of 'subjective' probability for statistical probability. This study examines clinicians' propensity to make estimations of subjective probability when presented with clinical information that is considered typical of a medical condition. The strength of the representativeness bias is tested by presenting choices in textual and graphic form. Understanding of statistical probability is also tested by omitting all clinical information. For the questions that included clinical information, 46.7% and 45.5% of clinicians made judgements of statistical probability, respectively. Where the question omitted clinical information, 79.9% of clinicians made a judgement consistent with statistical probability. There was a statistically significant difference in responses to the questions with and without representativeness information (χ2 (1, n=254)=54.45, pprobability. One of the causes for this representativeness bias may be the way clinical medicine is taught where stereotypic presentations are emphasised in diagnostic decision making. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Nanophotonics for Molecular Diagnostics and Therapy Applications

    Directory of Open Access Journals (Sweden)

    João Conde

    2012-01-01

    Full Text Available Light has always fascinated mankind and since the beginning of recorded history it has been both a subject of research and a tool for investigation of other phenomena. Today, with the advent of nanotechnology, the use of light has reached its own dimension where light-matter interactions take place at wavelength and subwavelength scales and where the physical/chemical nature of nanostructures controls the interactions. This is the field of nanophotonics which allows for the exploration and manipulation of light in and around nanostructures, single molecules, and molecular complexes. What is more is the use of nanophotonics in biomolecular interactions—nanobiophotonics—has prompt for a plethora of molecular diagnostics and therapeutics making use of the remarkable nanoscale properties. In this paper, we shall focus on the uses of nanobiophotonics for molecular diagnostics involving specific sequence characterization of nucleic acids and for gene delivery systems of relevance for therapy strategies. The use of nanobiophotonics for the combined diagnostics/therapeutics (theranostics will also be addressed, with particular focus on those systems enabling the development of safer, more efficient, and specific platforms. Finally, the translation of nanophotonics for theranostics into the clinical setting will be discussed.

  4. [Clinical decision making and critical thinking in the nursing diagnostic process].

    Science.gov (United States)

    Müller-Staub, Maria

    2006-10-01

    The daily routine requires complex thinking processes of nurses, but clinical decision making and critical thinking are underestimated in nursing. A great demand for educational measures in clinical judgement related with the diagnostic process was found in nurses. The German literature hardly describes nursing diagnoses as clinical judgements about human reactions on health problems / life processes. Critical thinking is described as an intellectual, disciplined process of active conceptualisation, application and synthesis of information. It is gained through observation, experience, reflection and communication and leads thinking and action. Critical thinking influences the aspects of clinical decision making a) diagnostic judgement, b) therapeutic reasoning and c) ethical decision making. Human reactions are complex processes and in their course, human behavior is interpreted in the focus of health. Therefore, more attention should be given to the nursing diagnostic process. This article presents the theoretical framework of the paper "Clinical decision making: Fostering critical thinking in the nursing diagnostic process through case studies".

  5. Real-Time Polymerase Chain Reaction: Applications in Diagnostic Microbiology

    Directory of Open Access Journals (Sweden)

    Kordo B. A. Saeed

    2013-11-01

    Full Text Available The polymerase chain reaction (PCR has revolutionized the detection of DNA and RNA. Real-Time PCR (RT-PCR is becoming the gold standard test for accurate, sensitive and fast diagnosis for a large range of infectious agents. Benefits of this procedure over conventional methods for measuring RNA include its sensitivity, high throughout and quantification. RT-PCR assays have advanced the diagnostic abilities of clinical laboratories particularly microbiology and infectious diseases. In this review we would like to briefly discuss RT-PCR in diagnostic microbiology laboratory, beginning with a general introduction to RT-PCR and its principles, setting up an RT PCR, including multiplex systems and the avoidance and remediation of contamination issues. A segment of the review would be devoted to the application of RT-PCR in clinical practice concentrating on its role in the diagnosis and treatment of infectious diseases.

  6. Clinical confrontation results of diagnostics and treatment of skin cancer

    International Nuclear Information System (INIS)

    Zikiryakhodjaev, D.Z.; Sanginov, D.R.

    2001-01-01

    In this chapter of book authors investigated the clinical confrontation results of diagnostics and treatment of skin cancer. They noted that diagnostic of skin cancer have to foresee the determination morphologic implements and degree of malignancy tumorous process why in general depend prognosis of illness

  7. Clinical and diagnostic importance of proteinuria: A review | Oni ...

    African Journals Online (AJOL)

    Clinical and diagnostic importance of proteinuria: A review. ... shown that diabetis mellitus, cardiovascular disease and hypertension could provoke secondary ... Proteinuria is also significant in some non-pathological cases such as pregnancy

  8. Diagnostic utility of clinical and biochemical parameters in ...

    African Journals Online (AJOL)

    Diagnostic utility of clinical and biochemical parameters in pancreatic head malignancy ... Department of Surgery, Sir Run Run Shaw Hospital College of Medicine, Zhejiang University, ..... technical review on the epidemiology, diagnosis, and.

  9. [Tinnitus: algorithm of diagnostics and clinical management].

    Science.gov (United States)

    Boiko, N V

    Hearing of sound, or tinnitus, can be a symptom of different diseases. The differential diagnosis should be based on the identification of subgroups with confirmed causes of the disease. Subjective and objective tinnitus groups should be isolated. Objective tinnitus can be vascular or muscular. In making a diagnosis of tinnitus, it is important to know its characteristics, laterality, circumstances of onset, duration, comorbidity with other symptoms: headache, hearing decline, dizziness, depression, etc. Urgent diagnostic and treatment measures are needed after the identification of 'red flags': acute pulsatile tinnitus, in particular after the brain injury, combination of tinnitus with acute hearing loss and depression.

  10. Measures to Improve Diagnostic Safety in Clinical Practice.

    Science.gov (United States)

    Singh, Hardeep; Graber, Mark L; Hofer, Timothy P

    2016-10-20

    Timely and accurate diagnosis is foundational to good clinical practice and an essential first step to achieving optimal patient outcomes. However, a recent Institute of Medicine report concluded that most of us will experience at least one diagnostic error in our lifetime. The report argues for efforts to improve the reliability of the diagnostic process through better measurement of diagnostic performance. The diagnostic process is a dynamic team-based activity that involves uncertainty, plays out over time, and requires effective communication and collaboration among multiple clinicians, diagnostic services, and the patient. Thus, it poses special challenges for measurement. In this paper, we discuss how the need to develop measures to improve diagnostic performance could move forward at a time when the scientific foundation needed to inform measurement is still evolving. We highlight challenges and opportunities for developing potential measures of "diagnostic safety" related to clinical diagnostic errors and associated preventable diagnostic harm. In doing so, we propose a starter set of measurement concepts for initial consideration that seem reasonably related to diagnostic safety and call for these to be studied and further refined. This would enable safe diagnosis to become an organizational priority and facilitate quality improvement. Health-care systems should consider measurement and evaluation of diagnostic performance as essential to timely and accurate diagnosis and to the reduction of preventable diagnostic harm.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  11. Angiomatous nasal polyp: Clinical diagnostic dilemma

    Directory of Open Access Journals (Sweden)

    Sunder Goyal

    2015-03-01

    Full Text Available Angiomatous polyp (Angiectatic nasal polyps is rare and its incidence is 4-5% of all nasal polyps. As it occurs with variable clinical features and there is no confirmatory preoperative investigation, clinical diagnosis can be a dilemma. Clinical picture of angiofibroma, simple antrochoanal polyp and inverted papilloma may resemble with each other. As polyps invade surrounding bone, these should be distinguished from a malignant mass. We present an interesting case of an infarcted angiectatic nasal polyp with extensive surrounding bony destruction. Correct preoperative radiological diagnosis is important to avoid unnecessary extensive surgery. Histopathological evaluation of polyps is mandatory since they require different treatment due to difference in the prognosis.

  12. Clinical application of ghrelin.

    Science.gov (United States)

    Strasser, Florian

    2012-01-01

    Ghrelin as a human natural hormone is involved in fundamental regulatory processes of eating and energy balance. Ghrelin signals the nutrient availability from the gastrointestinal tract to the central nervous system, up-regulates food intake and lowers energy expenditure mainly through hypothalamic mediators acting both centrally and peripherally including the gastrointestinal tract (motility, epithelium), promotes both neuro-endocrine and inflammatory signals to increase skeletal muscle growth and decrease protein breakdown, and increases lipolysis while body fat utilization is reduced. Ghrelin does more to exert its probably sentinel role around "human energy": it influences through mainly extra-hypothalamic actions the hedonic and incentive value of food, mood and anxiety, sleep-wake regulation, learning and memory, and neurogenesis. Recently numerous ghrelin gene-derived peptides were discovered, demonstrating the complexity within the ghrelin/ghrelin receptor axis. For clinical applications, not only the natural ghrelin and its slice variants, but also several modified or artificial molecules acting at ghrelin-associated receptors were and are developed. Current clinical applications are limited to clinical studies, focusing mainly on cachexia in chronic heart failure, COPD, cancer, endstage- renal-disease or cystic fibrosis, but also on frailty in elderly, gastrointestinal motility (e.g., gastroparesis, functional dyspepsia, postoperative ileus), after curative gastrectomy, anorexia nervosa, growth hormone deficient patients, alcohol craving, sleep-wake regulation (e.g. major depression), or sympathetic nervous activity in obesity. The results of completed, preliminary studies support the clinical potential of ghrelin, ghrelin gene-derived peptides, and artificial analogues, suggesting that larger clinical trials are demanded to move ghrelin towards an available and reimbursed pharmaceutical intervention.

  13. Neural network application to diesel generator diagnostics

    International Nuclear Information System (INIS)

    Logan, K.P.

    1990-01-01

    Diagnostic problems typically begin with the observation of some system behavior which is recognized as a deviation from the expected. The fundamental underlying process is one involving pattern matching cf observed symptoms to a set of compiled symptoms belonging to a fault-symptom mapping. Pattern recognition is often relied upon for initial fault detection and diagnosis. Parallel distributed processing (PDP) models employing neural network paradigms are known to be good pattern recognition devices. This paper describes the application of neural network processing techniques to the malfunction diagnosis of subsystems within a typical diesel generator configuration. Neural network models employing backpropagation learning were developed to correctly recognize fault conditions from the input diagnostic symptom patterns pertaining to various engine subsystems. The resulting network models proved to be excellent pattern recognizers for malfunction examples within the training set. The motivation for employing network models in lieu of a rule-based expert system, however, is related to the network's potential for generalizing malfunctions outside of the training set, as in the case of noisy or partial symptom patterns

  14. Atherosclerosis and Nanotechnology: Diagnostic and Therapeutic Applications.

    Science.gov (United States)

    Kratz, Jeremy D; Chaddha, Ashish; Bhattacharjee, Somnath; Goonewardena, Sascha N

    2016-02-01

    Over the past several decades, tremendous advances have been made in the understanding, diagnosis, and treatment of coronary artery disease (CAD). However, with shifting demographics and evolving risk factors we now face new challenges that must be met in order to further advance are management of patients with CAD. In parallel with advances in our mechanistic appreciation of CAD and atherosclerosis, nanotechnology approaches have greatly expanded, offering the potential for significant improvements in our diagnostic and therapeutic management of CAD. To realize this potential we must go beyond to recognize new frontiers including knowledge gaps between understanding atherosclerosis to the translation of targeted molecular tools. This review highlights nanotechnology applications for imaging and therapeutic advancements in CAD.

  15. Comparison of clinical judgment and diagnostic ultrasonography in the diagnosis of acute appendicitis

    DEFF Research Database (Denmark)

    Jahn, H; Mathiesen, F K; Neckelmann, K

    1997-01-01

    , and diagnostic aids are desirable to reduce the negative appendicectomy rate. Diagnostic US performed poorly as a routine procedure. Application of an up to date scoring system might be of some help to patients with a high or low probability of acute appendicitis, but any conclusion about its clinical......OBJECTIVE: To evaluate the diagnostic accuracy of clinical judgment and diagnostic ultrasonography (US) used routinely and to create a scoring system to aid diagnosis. DESIGN: Prospective, double-blind study. SETTING: University hospital, Denmark. SUBJECTS: 222 Consecutive patients suspected...... of having acute appendicitis admitted between 0800 and midnight from June 1990 to June 1992. INTERVENTIONS: 148 Patients (67%) underwent appendicectomy and the remaining 74 patients were observed. 193 Patients (87%) had a diagnostic US examination. 21 Predictive variables were collected prospectively...

  16. Clinical and Diagnostic Aspects of Diabetic Ketoacidosis

    Directory of Open Access Journals (Sweden)

    Z.P. Nizhynska-Аstapenko

    2016-05-01

    Full Text Available Background. Leading criteria for laboratory diagnosis and determination of diabetic ketoacidosis severity are considered to be the levels of glucose, blood pH and blood bicarbonate. Technological capabilities of a family doctor are very limited. Therefore, knowledge of detailed clinical symptoms will help the physician to establish correctly a provisional diagnosis and refer a patient to a specialized institution. The aim of our study was to determine the prevalence and special features of certain clinical symptoms and basic laboratory parameters in order to establish the severity level of diabetic ketoacidosis (DKA and to reveal certain correlation between clinical symptoms and laboratory changes in the blood in patients with DKA. Materials and methods. The study involved 123 patients with acute critical decompensated diabetes aged from 9 to 65 years old. We studied the clinical symptoms, measured biochemical changes in blood, blood gas and acid-base state. Results. There was not determined the correlation between severity of diabetic ketoacidosis and clinical parameters and acid-base balance in patients. There were determined the peculiarities electrolyte changes and the emergence gas metabolic changes on the cell level under ketosis, which further deepened with the development of ketoacidosis. The results of the study indicate the need for a comparison of clinical symptoms and laboratory parameters of pathogenic treatment, taking into account the cumulative data. These recommendations in the protocols are often attached to a single laboratory value and can not always fully comply with the severity of the condition. Conclusions. Blood gas is the most sensitive criterion of metabolic changes in case of diabetic ketoacidosis. The level of blood potassium can be used as an indicator of DKA severity. The level of blood potassium at admission to hospital does not really reflect its deficiency in the tissues.

  17. Vibrational spectroscopy: a clinical tool for cancer diagnostics.

    Science.gov (United States)

    Kendall, Catherine; Isabelle, Martin; Bazant-Hegemark, Florian; Hutchings, Joanne; Orr, Linda; Babrah, Jaspreet; Baker, Rebecca; Stone, Nicholas

    2009-06-01

    Vibrational spectroscopy techniques have demonstrated potential to provide non-destructive, rapid, clinically relevant diagnostic information. Early detection is the most important factor in the prevention of cancer. Raman and infrared spectroscopy enable the biochemical signatures from biological tissues to be extracted and analysed. In conjunction with advanced chemometrics such measurements can contribute to the diagnostic assessment of biological material. This paper also illustrates the complementary advantage of using Raman and FTIR spectroscopy technologies together. Clinical requirements are increasingly met by technological developments which show promise to become a clinical reality. This review summarises recent advances in vibrational spectroscopy and their impact on the diagnosis of cancer.

  18. Potential Applications of the National Institute of Mental Health's Research Domain Criteria (RDoC) to Clinical Psychiatric Practice: How RDoC Might Be Used in Assessment, Diagnostic Processes, Case Formulation, Treatment Planning, and Clinical Notes.

    Science.gov (United States)

    Yager, Joel; Feinstein, Robert E

    2017-04-01

    Offering a new framework for understanding and studying basic dimensions of normal and abnormal human functioning and mental disorders, the National Institute of Mental Health (NIMH) has initiated the Research Domain Criteria (RDoC) project in which a series of higher order domains, representing major systems of emotion, cognition, motivation, and social behavior, and their constituent operationally defined constructs serve as organizing templates for further research and inquiry, eg, to discover validated biomarkers and endophenotypes. Cutting across traditional DSM diagnoses, the domains are defined as Negative Valence Systems, Positive Valence Systems, Cognitive Systems, Systems for Social Processes, and Arousal/Regulatory Systems. To inform educators, trainees, and practitioners about RDoC, alert them to potential practical applications, and encourage their broad exploration in clinical settings, this article reviews the RDoC domains and their subsystem constructs with regard to potential current clinical considerations and applications. We describe ways in which the RDoC domains and constructs offer transdiagnostic frameworks for complementing traditional practice; suggest clinical questions to help elucidate salient information; and, translating RDoC domains and constructs headings into clinically friendly language, offer a template for the psychiatric review of systems that can serve in clinical notes. © Copyright 2017 Physicians Postgraduate Press, Inc.

  19. Circulating tumor cell isolation and diagnostics: toward routine clinical use

    NARCIS (Netherlands)

    Stolpe, van de A.; Pantel, K.; Sleijfer, S.; Terstappen, L.W.; Toonder, den J.M.J.

    2011-01-01

    From February 7–11, 2011, the multidisciplinary Lorentz Workshop Circulating Tumor Cell (CTC) Isolation and Diagnostics: Toward Routine Clinical Use was held in Leiden (The Netherlands) to discuss progress and define challenges and potential solutions for development of clinically useful circulating

  20. Clinical applications of preimplantation genetic testing.

    Science.gov (United States)

    Brezina, Paul R; Kutteh, William H

    2015-02-19

    Genetic diagnostic technologies are rapidly changing the way medicine is practiced. Preimplantation genetic testing is a well established application of genetic testing within the context of in vitro fertilization cycles. It involves obtaining a cell(s) from a developing embryo in culture, which is then subjected to genetic diagnostic analysis; the resulting information is used to guide which embryos are transferred into the uterus. The potential applications and use of this technology have increased in recent years. Experts agree that preimplantation genetic diagnosis is clinically appropriate for many known genetic disorders. However, some applications of such testing, such as preimplantation genetic screening for aneuploidy, remain controversial. Clinical data suggest that preimplantation genetic screening may be useful, but further studies are needed to quantify the size of the effect and who would benefit most. © BMJ Publishing Group Ltd 2015.

  1. 78 FR 39327 - Bio Diagnostic International; Denial of Application

    Science.gov (United States)

    2013-07-01

    ... DEPARTMENT OF JUSTICE Drug Enforcement Administration [Docket No. 11-63] Bio Diagnostic... Control, Drug Enforcement Administration, issued an Order to Show Cause to Bio Diagnostic International... application of Bio Diagnostic International, Inc., for a DEA Certificate of Registration as a distributor of...

  2. Applications of FT-IR spectrophotometry in cancer diagnostics.

    Science.gov (United States)

    Bunaciu, Andrei A; Hoang, Vu Dang; Aboul-Enein, Hassan Y

    2015-01-01

    This review provides a brief background to the application of infrared spectroscopy, including Fourier transform-infrared spectroscopy, in biological fluids. It is not meant to be complete or exhaustive but to provide the reader with sufficient background for selected applications in cancer diagnostics. Fourier transform-infrared spectroscopy (FT-IR) is a fast and nondestructive analytical method. The infrared spectrum of a mixture serves as the basis to quantitate its constituents, and a number of common clinical chemistry tests have proven to be feasible using this approach. This review focuses on biomedical FT-IR applications, published in the period 2009-2013, used for early detection of cancer through qualitative and quantitative analysis.

  3. Clinical advances of nanocarrier-based cancer therapy and diagnostics.

    Science.gov (United States)

    Luque-Michel, Edurne; Imbuluzqueta, Edurne; Sebastián, Víctor; Blanco-Prieto, María J

    2017-01-01

    Cancer is a leading cause of death worldwide and efficient new strategies are urgently needed to combat its high mortality and morbidity statistics. Fortunately, over the years, nanotechnology has evolved as a frontrunner in the areas of imaging, diagnostics and therapy, giving the possibility of monitoring, evaluating and individualizing cancer treatments in real-time. Areas covered: Polymer-based nanocarriers have been extensively studied to maximize cancer treatment efficacy and minimize the adverse effects of standard therapeutics. Regarding diagnosis, nanomaterials like quantum dots, iron oxide nanoparticles or gold nanoparticles have been developed to provide rapid, sensitive detection of cancer and, therefore, facilitate early treatment and monitoring of the disease. Therefore, multifunctional nanosystems with both imaging and therapy functionalities bring us a step closer to delivering precision/personalized medicine in the cancer setting. Expert opinion: There are multiple barriers for these new nanosystems to enter the clinic, but it is expected that in the near future, nanocarriers, together with new 'targeted drugs', could replace our current treatments and cancer could become a nonfatal disease with good recovery rates. Joint efforts between scientists, clinicians, the pharmaceutical industry and legislative bodies are needed to bring to fruition the application of nanosystems in the clinical management of cancer.

  4. [Diagnostic of secondary hypertension in clinical practice].

    Science.gov (United States)

    Somlóová, Z; Rosa, J; Petrák, O; Strauch, B; Zelinka, T; Holaj, R; Widimský, J

    2011-09-01

    Arterial hypertension is a common worldwide disease with a prevalence of approximately 26%. Secondary cause is known in 5-10% of patients with hypertension. We should think of secondary hypertension in all patients with resistant hypertension, in patients with sudden deterioration in the control of hypertension and in patients with laboratory and clinical signs of diseases associated with secondary hypertension. It is important to distinguish between secondary hypertension and pseudo-resistance (noncompliance to treatment, white coat syndrome). Secondary causes of hypertension can be divided into endocrine (primary aldosteronism, pheochromocytoma, hypercortisolism, hyperparathyreoidism), renal - renovascular and renal parenchymal hypertension, and other causes as sleep apnoe syndrome, hypertension in pregnancy, coarctation of the aorta and intracranial tumors.

  5. Cognitive development, clinical knowledge, and clinical experience related to diagnostic ability.

    Science.gov (United States)

    Aquilino, M L

    1997-01-01

    To examine the relationship among cognitive development, clinical knowledge, and clinical experience in nursing students. A survey of junior and senior baccalaureate nursing students from three Midwestern colleges (N = 55). Students' diagnostic ability increased as they gained clinical experience and clinical knowledge. However, students failed to identify many nursing diagnoses and demonstrated only moderate levels of cognitive development. Nurse educators and nursing students need to change their approaches to teaching and learning to enhance students' diagnostic ability and cognitive development.

  6. Molecular diagnostics clinical utility strategy: a six-part framework.

    Science.gov (United States)

    Frueh, Felix W; Quinn, Bruce

    2014-09-01

    The clinical utility of a molecular test rises proportional to a favorable regulatory risk/benefit assessment, and clinical utility is the driver of payer coverage decisions. Although a great deal has been written about clinical utility, debates still center on its 'definition.' We argue that the definition (an impact on clinical outcomes) is self-evident, and improved communications should focus on sequential steps in building and proving an adequate level of confidence for the diagnostic test's clinical value proposition. We propose a six-part framework to facilitate communications between test developers and health technology evaluators, relevant to both regulatory and payer decisions.

  7. Hashimoto thyroiditis: clinical and diagnostic criteria.

    Science.gov (United States)

    Caturegli, P; De Remigis, A; Rose, N R

    2014-01-01

    Hashimoto thyroiditis (HT), now considered the most common autoimmune disease, was described over a century ago as a pronounced lymphoid goiter affecting predominantly women. In addition to this classic form, several other clinico-pathologic entities are now included under the term HT: fibrous variant, IgG4-related variant, juvenile form, Hashitoxicosis, and painless thyroiditis (sporadic or post-partum). All forms are characterized pathologically by the infiltration of hematopoietic mononuclear cells, mainly lymphocytes, in the interstitium among the thyroid follicles, although specific features can be recognized in each variant. Thyroid cells undergo atrophy or transform into a bolder type of follicular cell rich in mitochondria called Hürthle cell. Most HT forms ultimately evolve into hypothyroidism, although at presentation patients can be euthyroid or even hyperthyroid. The diagnosis of HT relies on the demonstration of circulating antibodies to thyroid antigens (mainly thyroperoxidase and thyroglobulin) and reduced echogenicity on thyroid sonogram in a patient with proper clinical features. The treatment remains symptomatic and based on the administration of synthetic thyroid hormones to correct the hypothyroidism as needed. Surgery is performed when the goiter is large enough to cause significant compression of the surrounding cervical structures, or when some areas of the thyroid gland mimic the features of a nodule whose cytology cannot be ascertained as benign. HT remains a complex and ever expanding disease of unknown pathogenesis that awaits prevention or novel forms of treatment. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Development and application of reactor noise diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, Joakim K.H

    1999-04-01

    A number of problems in reactor noise diagnostics have been investigated within the framework of the present thesis. The six papers presented cover three relatively different areas, namely the use of analytical calculations of the neutron noise in simple reactor models, some aspects of boiling water reactor (BWR) stability and diagnostics of core barrel motion in pressurized water reactors (PWRs). The noise induced by small vibrations of a strong absorber has been the subject of several previous investigations. For a conventional {delta}-function source model, the equations can not be linearized in the traditional manner. Thus, a new source model, which is called the {epsilon}/d model, was developed. The correct solution has been derived in the {epsilon}/d model for both 1-D and 2-D reactor models. Recently, several reactor diagnostic problems have occurred which include a control rod partially inserted into the reactor core. In order to study such problems, we have developed an analytically solvable, axially non-homogenous, 2-D reactor model. This model has also been used to study the noise induced by a rod maneuvering experiment. Comparisons of the noise with the results of different reactor kinetic approximations have yielded information on the validity of the approximations in this relatively realistic model. In case of an instability event in a BWR, the noise may consist of one or several co-existing modes of oscillation and besides the fundamental mode, a regional first azimuthal mode has been observed in e.g. the Swedish BWR Ringhals-1. In order to determine the different stability characteristics of the different modes separately, it is important to be able to decompose the noise into its mode constituents. A separation method based on factorisation of the flux has been attempted previously, but without success. The reason for the failure of the factorisation method is the presence of the local component of the noise and its axial correlation properties. In

  9. Development and application of reactor noise diagnostics

    International Nuclear Information System (INIS)

    Karlsson, Joakim K.H.

    1999-04-01

    A number of problems in reactor noise diagnostics have been investigated within the framework of the present thesis. The six papers presented cover three relatively different areas, namely the use of analytical calculations of the neutron noise in simple reactor models, some aspects of boiling water reactor (BWR) stability and diagnostics of core barrel motion in pressurized water reactors (PWRs). The noise induced by small vibrations of a strong absorber has been the subject of several previous investigations. For a conventional δ-function source model, the equations can not be linearized in the traditional manner. Thus, a new source model, which is called the ε/d model, was developed. The correct solution has been derived in the ε/d model for both 1-D and 2-D reactor models. Recently, several reactor diagnostic problems have occurred which include a control rod partially inserted into the reactor core. In order to study such problems, we have developed an analytically solvable, axially non-homogenous, 2-D reactor model. This model has also been used to study the noise induced by a rod maneuvering experiment. Comparisons of the noise with the results of different reactor kinetic approximations have yielded information on the validity of the approximations in this relatively realistic model. In case of an instability event in a BWR, the noise may consist of one or several co-existing modes of oscillation and besides the fundamental mode, a regional first azimuthal mode has been observed in e.g. the Swedish BWR Ringhals-1. In order to determine the different stability characteristics of the different modes separately, it is important to be able to decompose the noise into its mode constituents. A separation method based on factorisation of the flux has been attempted previously, but without success. The reason for the failure of the factorisation method is the presence of the local component of the noise and its axial correlation properties. In the paper

  10. Should we confirm our clinical diagnostic certainty by autopsies?

    Science.gov (United States)

    Podbregar, M; Voga, G; Krivec, B; Skale, R; Pareznik, R; Gabrscek, L

    2001-11-01

    To evaluate the frequency of diagnostic errors assessed by autopsies. Retrospective review of medical and pathological records in an 11-bed closed medical intensive care unit (ICU) at a 860-bed general hospital. Patients who died in the ICU between January 1998 and December 1999. Medical diagnoses were rated into three levels of clinical diagnostic certainty: complete certainty (group L1), minor diagnostic uncertainty (group L2), and major diagnostic uncertainty (group L3). The patients were divided into three error groups: group A, the autopsy confirmed the clinical diagnosis; group B, the autopsy demonstrated a new relevant diagnosis which would probably not have influenced the therapy and outcome; group C, the autopsy demonstrated a new relevant diagnosis which would probably have changed the therapy and outcome. The overall mortality was 20.3% (270/1331 patients). Autopsies were performed in 126 patients (46.9% of deaths), more often in younger patients (66.6+/-13.9 years vs 72.7+/-12.0 years, p<0.001), in patients with shorter ICU stay (4.7+/-5.6 days vs 6.7+/-8.7 days, p=0.054), and in patients in group L3 without chronic diseases (15/126 vs 1/144, p<0.001). Fatal but potentially treatable errors [group C, 12 patients (9.5%)] were found in 8.7%, 10.0%, and 10.5% of patients in groups L1, L2, and L3, respectively (NS between groups). An ICU length of stay shorter than 24 h was not related to the frequency of group C errors. Autopsies are performed more often in younger patients without chronic disease and in patients with a low clinical diagnostic certainty. No level of clinical diagnostic certainty could predict the pathological findings.

  11. Teaching perceptual skills in clinical diagnostics using digital media

    NARCIS (Netherlands)

    Scheiter, Katharina; Jarodzka, Halszka

    2011-01-01

    Scheiter, K., & Jarodzka, H. (2011, May). Teaching perceptual skills in clinical diagnostics using digital media. Presentation at the 2nd International Conference “Research in Medical Education”: Shaping diamonds from bench to bedside, Universität Tübingen.

  12. Diagnostic utility of clinical and biochemical parameters in ...

    African Journals Online (AJOL)

    Diagnostic utility of clinical and biochemical parameters in pancreatic head malignancy patients with normal carbohydrate antigen 19-9 levels. Xiaoli Jin1, Yulian Wu2. 1. Department of Surgery, Sir Run Run Shaw Hospital College of Medicine, Zhejiang University, 3 Qingchun. Road East, Hangzhou, Zhejiang Province ...

  13. Evaluating online diagnostic decision support tools for the clinical setting.

    Science.gov (United States)

    Pryor, Marie; White, David; Potter, Bronwyn; Traill, Roger

    2012-01-01

    Clinical decision support tools available at the point of care are an effective adjunct to support clinicians to make clinical decisions and improve patient outcomes. We developed a methodology and applied it to evaluate commercially available online clinical diagnostic decision support (DDS) tools for use at the point of care. We identified 11 commercially available DDS tools and assessed these against an evaluation instrument that included 6 categories; general information, content, quality control, search, clinical results and other features. We developed diagnostically challenging clinical case scenarios based on real patient experience that were commonly missed by junior medical staff. The evaluation was divided into 2 phases; an initial evaluation of all identified and accessible DDS tools conducted by the Clinical Information Access Portal (CIAP) team and a second phase that further assessed the top 3 tools identified in the initial evaluation phase. An evaluation panel consisting of senior and junior medical clinicians from NSW Health conducted the second phase. Of the eleven tools that were assessed against the evaluation instrument only 4 tools completely met the DDS definition that was adopted for this evaluation and were able to produce a differential diagnosis. From the initial phase of the evaluation 4 DDS tools scored 70% or more (maximum score 96%) for the content category, 8 tools scored 65% or more (maximum 100%) for the quality control category, 5 tools scored 65% or more (maximum 94%) for the search category, and 4 tools score 70% or more (maximum 81%) for the clinical results category. The second phase of the evaluation was focused on assessing diagnostic accuracy for the top 3 tools identified in the initial phase. Best Practice ranked highest overall against the 6 clinical case scenarios used. Overall the differentiating factor between the top 3 DDS tools was determined by diagnostic accuracy ranking, ease of use and the confidence and

  14. Advancing Porous Silicon Biosensor Technology for Use in Clinical Diagnostics

    Science.gov (United States)

    Bonanno, Lisa Marie

    Inexpensive and robust analytical techniques for detecting molecular recognition events are in great demand in healthcare, food safety, and environmental monitoring. Despite vast research in this area, challanges remain to develop practical biomolecular platforms that, meet the rigorous demands of real-world applications. This includes maintaining low-cost devices that are sensitive and specific in complex test specimens, are stable after storage, have short assay time, and possess minimal complexity of instrumentation for readout. Nanostructured porous silicon (PSi) material has been identified as an ideal candidate towards achieving these goals and the past decade has seen diverse proof-of-principle studies developing optical-based sensing techniques. In Part 1 of this thesis, the impact of surface chemistry and PSi morphology on detection sensitivity of target molecules is investigated. Initial proof-of-concept that PSi devices facilitate detection of protein in whole blood is demonstrated. This work highlights the importance of material stability and blocking chemistry for sensor use in real world biological samples. In addition, the intrinisic filtering capability of the 3-D PSi morphology is shown as an advantage in complex solutions, such as whole blood. Ultimately, this initial work identified a need to improve detection sensitivity of the PSI biosensor technique to facilitate clinical diagnostic use over relevant target concentration ranges. The second part of this thesis, builds upon sensitivity challenges that are highlighted in the first part of the thesis and development of a surface-bound competitive inhibition immunoassay facilitated improved detection sensitivity of small molecular weight targets (opiates) over a relevant clinical concentration range. In addition, optimization of assay protocol addressed issues of maintaining stability of sensors after storage. Performance of the developed assay (specificity and sensitivity) was then validated in a

  15. Implementation of Targeted Next Generation Sequencing in Clinical Diagnostics

    DEFF Research Database (Denmark)

    Larsen, Martin Jakob; Burton, Mark; Thomassen, Mads

    Accurate mutation detection is essential in clinical genetic diagnostics of monogenic hereditary diseases. Targeted next generation sequencing (NGS) provides a promising and cost-effective alternative to Sanger sequencing and MLPA analysis currently used in most diagnostic laboratories. One...... of mutation positive controls previously characterized by Sanger/MLPA analysis. Agilent SureSelect Target-Enrichment kits were used for capturing a set of genes associated with hereditary breast and ovarian cancer syndrome and a compilation of genes involved in multiple rare single gene disorders......, respectively. For diagnostics, the sequencing coverage is essential, wherefore a minimum coverage of 30x per nucleotide in the coding regions was used as our primary quality criterion. For the majority of the included genes, we obtained adequate gene coverage, in which we were able to detect 100% of the known...

  16. Skeletal diseases. Diagnostic clinical radiology and differential diagnostics. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Freyschmidt, J.

    1997-01-01

    The book focuses on the diagnostic evaluation of idiopathic diseases of the skeleton and bone joints, also including the fundamental healing processes of bone fractures, particularly of stress-induced and pathologic fractures. Ample space has been given to the description and imaging of the course of diseases under treatment by up-to-date therapies, as e.g. for ostitis deformans Paget's disease, or skeletal metastases. This second edition of the book incorporates the progress achieved over the last five years in skeletal diagnostics. The advances in this field have been resulting from basic research work, for instance in molecular biology, or from a variety of completed studies relating to clinical medicine, laboratory chemistry, histopathology and radiology of skeletal diseases, and from experience obtained with the diagnostic radiology methods and techniques, with the potentials and constraints of magnetic resonance imaging (MRI) today being more critically assessed than five years ago. MRI is a modality currently meeting with interest in the context of search for additional diagnostic information, new definition of complete pictures of diseases, or false or overinterpretation of diagnostic findings. (orig./MG). 431 figs [de

  17. Fear of knowledge: Clinical hypotheses in diagnostic and prognostic reasoning.

    Science.gov (United States)

    Chiffi, Daniele; Zanotti, Renzo

    2017-10-01

    Patients are interested in receiving accurate diagnostic and prognostic information. Models and reasoning about diagnoses have been extensively investigated from a foundational perspective; however, for all its importance, prognosis has yet to receive a comparable degree of philosophical and methodological attention, and this may be due to the difficulties inherent in accurate prognostics. In the light of these considerations, we discuss a considerable body of critical thinking on the topic of prognostication and its strict relations with diagnostic reasoning, pointing out the distinction between nosographic and pathophysiological types of diagnosis and prognosis, underlying the importance of the explication and explanation processes. We then distinguish between various forms of hypothetical reasoning applied to reach diagnostic and prognostic judgments, comparing them with specific forms of abductive reasoning. The main thesis is that creative abduction regarding clinical hypotheses in diagnostic process is very unlikely to occur, whereas this seems to be often the case for prognostic judgments. The reasons behind this distinction are due to the different types of uncertainty involved in diagnostic and prognostic judgments. © 2016 John Wiley & Sons, Ltd.

  18. Recent progress in nanomedicine: therapeutic, diagnostic and theranostic applications

    NARCIS (Netherlands)

    Rizzo, L.Y.; Theek, B.; Storm, Gerrit; Kiessling, F.; Lammers, Twan Gerardus Gertudis Maria

    2013-01-01

    In recent years, the use of nanomedicine formulations for therapeutic and diagnostic applications has increased exponentially. Many different systems and strategies have been developed for drug targeting to pathological sites, as well as for visualizing and quantifying important (patho-)

  19. Point-of-care diagnostics for niche applications.

    Science.gov (United States)

    Cummins, Brian M; Ligler, Frances S; Walker, Glenn M

    2016-01-01

    Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Clinical application of radioimmunoassays

    International Nuclear Information System (INIS)

    Dolecek, R.

    1974-01-01

    The normal average values of immunoreactive insulin (IRI) in the course of the glycemic curve and in glycemia in patients suffering from diabetes, acromegaly and in diagnostics of insulinomas are given. Changes of IRI values after peroral loading with glucose in obese patients and in patients suffering from burns are given. The values of the growth hormone (STH) are given: normal, in patients suffering from obesity, children of small growth, patients with severe burns and in patients suffering from pneumoconiosis with quick progression. The conditions are also stated for the determination of the levels of the luteinizing hormone and the follicle-stimulating hormone, the human placental lactogen and values of renin activity and angiotensin in patients suffering from burns, the values of the adrenocorticotropic hormone and the thyreotropic hormone. (J.P.)

  1. Development of genomic based diagnostics in various application domains

    DEFF Research Database (Denmark)

    Szallasi, Zoltan Imre

    2017-01-01

    We will review the revolution brought about by low cost next generation sequencing in a wide array of diagnostic and industrial applications with a special emphasis on computational requirements and big data challenges.......We will review the revolution brought about by low cost next generation sequencing in a wide array of diagnostic and industrial applications with a special emphasis on computational requirements and big data challenges....

  2. The application of automated deductive reasoning to power plant diagnostics

    International Nuclear Information System (INIS)

    Filshtein, E.L.; Rzasa, P.W.

    1986-01-01

    A module which incorporates the application of deductive reasoning to diagnostics has been developed. This module is a part of a generic diagnostic expert system prototype developed for power plant operations at Combustion Engineering. This paper is one of a series of papers which will describe the activities of the project. Specifically, this paper describes the deductive reasoning module which determines and classifies root cause malfunctions. The concept of 'perfect instruments' is introduced. These instruments are imaginary instruments which bridge the gap between real world inputs and the generic diagnostic shell. The prototype, its application, and future developments are discussed

  3. Novel applications of array comparative genomic hybridization in molecular diagnostics.

    Science.gov (United States)

    Cheung, Sau W; Bi, Weimin

    2018-05-31

    In 2004, the implementation of array comparative genomic hybridization (array comparative genome hybridization [CGH]) into clinical practice marked a new milestone for genetic diagnosis. Array CGH and single-nucleotide polymorphism (SNP) arrays enable genome-wide detection of copy number changes in a high resolution, and therefore microarray has been recognized as the first-tier test for patients with intellectual disability or multiple congenital anomalies, and has also been applied prenatally for detection of clinically relevant copy number variations in the fetus. Area covered: In this review, the authors summarize the evolution of array CGH technology from their diagnostic laboratory, highlighting exonic SNP arrays developed in the past decade which detect small intragenic copy number changes as well as large DNA segments for the region of heterozygosity. The applications of array CGH to human diseases with different modes of inheritance with the emphasis on autosomal recessive disorders are discussed. Expert commentary: An exonic array is a powerful and most efficient clinical tool in detecting genome wide small copy number variants in both dominant and recessive disorders. However, whole-genome sequencing may become the single integrated platform for detection of copy number changes, single-nucleotide changes as well as balanced chromosomal rearrangements in the near future.

  4. Prostate cancer diagnostics: Clinical challenges and the ongoing need for disruptive and effective diagnostic tools.

    Science.gov (United States)

    Sharma, Shikha; Zapatero-Rodríguez, Julia; O'Kennedy, Richard

    The increased incidence and the significant health burden associated with carcinoma of the prostate have led to substantial changes in its diagnosis over the past century. Despite technological advancements, the management of prostate cancer has become progressively more complex and controversial for both early and late-stage disease. The limitations and potential harms associated with the use of prostate-specific antigen (PSA) as a diagnostic marker have stimulated significant investigation of numerous novel biomarkers that demonstrate varying capacities to detect prostate cancer and can decrease unnecessary biopsies. However, only a few of these markers have been approved for specific clinical settings while the others have not been adequately validated for use. This review systematically and critically assesses ongoing issues and emerging challenges in the current state of prostate cancer diagnostic tools and the need for disruptive next generation tools based on analysis of combinations of these biomarkers to enhance predictive accuracy which will benefit clinical diagnostics and patient welfare. Copyright © 2016. Published by Elsevier Inc.

  5. Radioimmunotherapy (II): clinical application

    International Nuclear Information System (INIS)

    Cheon, Gi Jeong; Kang, Hye Jin; Lim, Sang Moo

    2006-01-01

    Molecular targeting may be defined as the specific concentration of a diagnostic or therapeutic tracer by its interaction with a molecular species that is distinctly present or absent in a disease state. Monoclonal antibody (mAb) is one of the successful agents for targeted therapy in cancer. To enhance the therapeutic effect. the concept of targeting radionuclides to tumors using radiolabeled mAbs against tumor-associated antigens, radioimmunotherapy, was proposed. The efficacy of radioimmunotherapy, however, has to be further optimized. Several strategies to improve targeting of tumors with radiolabeled mAbs have been developed, such as the use of mAb fragments, the use of high-affinity mAbs, the use of labeling techniques that are stable in vivo, active removal of the radiolabeled mAb from the circulation, and pretargeting strategies. Until now, however, there are many kinds of obstacles to be solved in the use of mAb for the targeted therapy. Major technical challenges to molecular targeting are related to the rapid and specific delivery of tracers to the target, the elimination of unwanted background activity, and the development of more specific targets to create a cytocidal effect. Further development of this field will be determined by success in solving these challenges

  6. Vi-da: vitiligo diagnostic assistance mobile application

    Science.gov (United States)

    Nugraha, G. A.; Nurhudatiana, A.; Bahana, R.

    2018-03-01

    Vitiligo is a skin disorder in which white patches of depigmentation appear on different parts of the body. Usually, patients come to hospitals or clinics to have their vitiligo conditions assessed. This can be very tiring to the patients, as vitiligo treatments usually take a relatively long period of time, which can range from months to years. To address this challenge, we present in this paper a prototype of an Android-based mobile application called Vi-DA, which stands for Vitiligo Diagnostic Assistance. Vi-DA consists of three subsystems, which are user sign-up subsystem, camera and image analysis subsystem, and progress report subsystem. The mobile application was developed in Java programming language and uses MySQL as the database system. Vi-DA adopts a vitiligo segmentation algorithm to segment input image into normal skin area, vitiligo skin area, and non-skin area. Results showed that Vi-DA gave comparable results to the previous system implemented in Matlab. User acceptance testing results also showed that all respondents agreed on the usefulness of the system and agreed to use Vi-DA again in the future. Vi-DA benefits both dermatologists and patients as not only a computer-aided diagnosis (CAD) tool but also as a smart application that can be used for self-assessment at home.

  7. Clinical diagnostic evaluation for scaphoid fractures: a systematic review and meta-analysis

    NARCIS (Netherlands)

    Mallee, Wouter H.; Henny, Erik P.; van Dijk, C. Niek; Kamminga, Sjoerd P.; van Enst, Wynanda A.; Kloen, Peter

    2014-01-01

    To provide an overview of available clinical evaluation tests for scaphoid fractures and to compare their diagnostic accuracies. PWe performed a systematic review of all studies assessing diagnostic characteristics of clinical evaluation in scaphoid fractures by searching MEDLINE, EMBASE, Cochrane,

  8. Clinical approach to obscure GI bleeding - Diagnostic testing and management

    Directory of Open Access Journals (Sweden)

    Prashanth Prabakaran

    2013-01-01

    Full Text Available Obscure gastrointestinal bleeding (OGIB can present as a diagnostic dilemma and management can be challenging. The search for causes of OGIB is usually centered on visualizing the small bowel, and in the past decade, the technology to visualize the entire small bowel has significantly advanced. Moreover, small bowel endoscopic imaging has replaced, in many instances, prior radiographic evaluation for obscure GI bleeding. These new modalities, such as small bowel capsule endoscopy (CE, balloon-assisted deep enteroscopy [double balloon enteroscopy (DBE and single balloon enteroscopy (SBE], and overtube-assisted deep enteroscopy (spiral enteroscopy, are paving the way toward more accurately identifying and treating patients with OGIB. We will review the diagnostic modalities available in evaluating a patient with OGIB and also propose the management based on clinical and endoscopic findings.

  9. Implementation of a companion diagnostic in the clinical laboratory

    DEFF Research Database (Denmark)

    Mancini, Irene; Pinzani, Pamela; Simi, Lisa

    2015-01-01

    A companion diagnostic test provides information that is essential for the safe and effective use of a corresponding therapeutic product as indicated in the drug instructions. The implementation of a companion diagnostic follows the rules of a molecular test for somatic mutations in a routine...... clinical laboratory environment and needs guidance on practical aspects, including the choice of the proper analytical method and the procedures for internal and external quality controls. Selection of the appropriate assay for detection of genetic alterations depends on several factors: the type...... on restrictions of the method used. In relation to these aspects herein we report an opinion paper of the Working Group Personalized Laboratory Medicine jointly constituted by the European Federation of Laboratory Medicine (EFLM) and by the European Society of Pharmacogenomics and Theranostics (ESPT) using...

  10. PERICARDITIS: ETIOLOGY, CLASSIFICATION, CLINIC, DIAGNOSTICS, TREATMENT. PART II

    Directory of Open Access Journals (Sweden)

    A.B. Sugak

    2009-01-01

    Full Text Available Pericarditis maybe caused by different agents: viruses, bacteria, tuberculosis, and it may be autoimmune. All these types of diseases have similar clinical signs, but differ by prevalence, prognosis and medical tactics. Due to achievements of radial methods of visualization, molecular biology, and immunology, we have an opportunity to provide early specific diagnostics and etiological treatment of inflammatory diseases of pericardium. The second part of lecture presents main principles of differential diagnostics of specific types of pericarditis, gives characteristics of several often accruing types of disease, and describes treatment and tactics of management of patients with pericarditis.Key words: children, pericarditis.(Voprosy sovremennoi pediatrii — Current Pediatrics. 2009;8(3:76-81

  11. Hypervelocity Dust Injection for Plasma Diagnostic Applications

    Science.gov (United States)

    Ticos, Catalin

    2005-10-01

    Hypervelocity micron-size dust grain injection was proposed for high-temperature magnetized plasma diagnosis. Multiple dust grains are launched simultaneously into high temperature plasmas at several km/s or more. The hypervelocity dust grains are ablated by the electron and ion fluxes. Fast imaging of the resulting luminous plumes attached to each grain is expected to yield local magnetic field vectors. Combination of multiple local magnetic field vectors reproduces 2D or even 3D maps of the internal magnetic field topology. Key features of HDI are: (1) a high spatial resolution, due to a relatively small transverse size of the elongated tail, and (2) a small perturbation level, as the dust grains introduce negligible number of particles compared to the plasma particle inventory. The latter advantage, however, could be seriously compromised if the gas load from the accelerator has an unobstructed access to the diagnosed plasma. Construction of a HDI diagnostic for National Spherical Torus Experiment (NSTX), which includes a coaxial plasma gun for dust grain acceleration, is underway. Hydrogen and deuterium gas discharges inside accelerator are created by a ˜ 1 mF capacitor bank pre-charged up to 10 kV. The diagnostic apparatus also comprises a dust dispenser for pre-loading the accelerator with dust grains, and an imaging system that has a high spatial and temporal resolution.

  12. Irritable bowel syndrome: diagnostic approaches in clinical practice

    Directory of Open Access Journals (Sweden)

    Eugene J Burbige

    2010-09-01

    Full Text Available Eugene J BurbigeDivision of Gastroenterology, Gastrointestinal and Liver Research, John Muir Medical Center, Concord, CA, USABackground: Irritable bowel syndrome (IBS, a functional gastrointestinal disorder long considered a diagnosis of exclusion, has chronic symptoms that vary over time and overlap with those of non-IBS disorders. Traditional symptom-based criteria effectively identify IBS patients but are not easily applied in clinical practice, leaving >40% of patients to experience symptoms up to 5 years before diagnosis.Objective: To review the diagnostic evaluation of patients with suspected IBS, strengths and weaknesses of current methodologies, and newer diagnostic tools that can augment current symptom-based criteria.Methods: The peer-reviewed literature (PubMed was searched for primary reports and reviews using the limiters of date (1999–2009 and English language and the search terms irritable bowel syndrome, diagnosis, gastrointestinal disease, symptom-based criteria, outcome, serology, and fecal markers. Abstracts from Digestive Disease Week 2008–2009 and reference lists of identified articles were reviewed.Results: A disconnect is apparent between practice guidelines and clinical practice. The American Gastroenterological Association and American College of Gastroenterology recommend diagnosing IBS in patients without alarm features of organic disease using symptom-based criteria (eg, Rome. However, physicians report confidence in a symptom-based diagnosis without further testing only up to 42% of the time; many order laboratory tests and perform sigmoidoscopies or colonoscopies despite good evidence showing no utility for this work-up in uncomplicated cases. In the absence of diagnostic criteria easily usable in a busy practice, newer diagnostic methods, such as stool-form examination, fecal inflammatory markers, and serum biomarkers, have been proposed as adjunctive tools to aid in an IBS diagnosis by increasing physicians

  13. [The challenges of standardization in clinical diagnostic laboratories of medical organizations].

    Science.gov (United States)

    Men'shikov, V V

    2013-04-01

    The generalized data concerning the conditions of application of regulations of national standards in clinical diagnostic laboratories of medical organizations is presented. The primary information was provided by 14 regions of 6 federal administrative okrugs of Russia. The causes of challenges of application of requirements of standards are presented. They are mostly related with insufficient financial support, lacking of manpower, difficulties with reagents supply, inadequate technical maintenance of devices and absence of support of administration of medical organizations. The recommendations are formulated concerning the necessity of publishing the document of Minzdrav of Russia to determine the need in application of standards in laboratory practice.

  14. Interpretation and clinical applications

    International Nuclear Information System (INIS)

    Higgins, C.B.

    1987-01-01

    This chapter discusses the factors to be kept in mind during routine interpretation of MR images. This includes the factors that determine contrast on standard spin-echo images and some distinguishing features between true lesions and artifactually simulated lesions. This chapter also indicates the standard protocols for MRI of various portions of the body. Finally, the current indications for MRI of various portions of the body are suggested; however, it is recognized that the indications for MRI are rapidly increasing and consequently, at the time of publication of this chapter, it is likely that many more applications will have become evident. Interpretation of magnetic resonance (MR) images requires consideration of anatomy and tissue characteristics and extraction of artifacts resulting from motion and other factors

  15. Microwave imaging for plasma diagnostics and its applications

    International Nuclear Information System (INIS)

    Mase, A.; Kogi, Y.; Ito, N.

    2007-01-01

    Microwave to millimeter-wave diagnostic techniques such as interferometry, reflectometry, scattering, and radiometry have been powerful tools for diagnosing magnetically confined plasmas. Important plasma parameters were measured to clarify the physics issues such as stability, wave phenomena, and fluctuation-induced transport. Recent advances in microwave and millimeter-wave technology together with computer technology have enabled the development of advanced diagnostics for visualization of 2D and 3D structures of plasmas. Microwave/millimeter-wave imaging is expected to be one of the most promising diagnostic methods for this purpose. We report here on the representative microwave diagnostics and their industrial applications as well as application to magnetically-confined plasmas. (author)

  16. Prostate cancer - epidemiology, etiology, diagnostics, clinical symptoms, screening

    International Nuclear Information System (INIS)

    Ondrus, D.

    2006-01-01

    Prostate cancer presents a real important medical and social problem at present. It is one of the most common malignancy in males. In global point of view it means permanent incidence increase of this disease. Despite improvement of prostate cancer diagnosis and complex treatment mortality does not decreased significantly. Knowledge of etiological factors are relatively limited. Important factors are: genetic disposition, age, life style, race, positive familial history, circulated androgens. Diagnostics is well known, based on routine clinical methods: digital rectal examination, measurement of PSA a transrectal ultrasound. Benefit of prostate cancer screening is until now unclear, controversial. (author)

  17. Application of tissue mesodissection to molecular cancer diagnostics.

    Science.gov (United States)

    Krizman, David; Adey, Nils; Parry, Robert

    2015-02-01

    To demonstrate clinical application of a mesodissection platform that was developed to combine advantages of laser-based instrumentation with the speed/ease of manual dissection for automated dissection of tissue off standard glass slides. Genomic analysis for KRAS gene mutation was performed on formalin fixed paraffin embedded (FFPE) cancer patient tissue that was dissected using the mesodissection platform. Selected reaction monitoring proteomic analysis for quantitative Her2 protein expression was performed on FFPE patient tumour tissue dissected by a laser-based instrument and the MilliSect instrument. Genomic analysis demonstrates highly confident detection of KRAS mutation specifically in lung cancer cells and not the surrounding benign, non-tumour tissue. Proteomic analysis demonstrates Her2 quantitative protein expression in breast cancer cells dissected manually, by laser-based instrumentation and by MilliSect instrumentation (mesodissection). Slide-mounted tissue dissection is commonly performed using laser-based instruments or manually scraping tissue by scalpel. Here we demonstrate that the mesodissection platform as performed by the MilliSect instrument for tissue dissection is cost-effective; it functions comparably to laser-based dissection and which can be adopted into a clinical diagnostic workflow. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Virtual colonoscopy: clinical application

    International Nuclear Information System (INIS)

    Laghi, A.

    2005-01-01

    Virtual colonoscopy (VC), also known as computed tomography Colonography (CTC), is a non-invasive test for the examination of the colon based on volumetric, thin-collimation CT acquisition of a cleansed and air-distended colon. The technique is easy, less labour-intensive than barium enema and conventional colonoscopy, and is inherently safer. Several studies demonstrate the ability of VC in the detection of colonic neoplastic lesions, not only large carcinomas, but also polyps. Currently, the most widely accepted clinical indication is incomplete or unsuccessful colonoscopy, which may be the result of redundant colon, patient intolerance to the procedure, spasm not resolving even with the use of spasmolytics, obstructing colo-rectal cancer. VC is also used to detect cancer in frail and immobile patients to avoid sedation during colonoscopy or the turning required during barium enema. The use of VC in patients under surveillance following colo-rectal cancer surgery is under investigation. Further studies are necessary in order to assess the cost-effectiveness of this approach. For colo-rectal cancer screening, a practical approach is to consider VC as a currently credible alternative screening method and as a reasonable alternative to the other colo-rectal cancer screening tests when a patient is unable or unwilling to undergo conventional colonoscopy. (orig.)

  19. Virtual colonoscopy: clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Laghi, A. [Univ. of Rome La Sapienza, Polo Didattico Pontino, Latina (Italy)

    2005-11-15

    Virtual colonoscopy (VC), also known as computed tomography Colonography (CTC), is a non-invasive test for the examination of the colon based on volumetric, thin-collimation CT acquisition of a cleansed and air-distended colon. The technique is easy, less labour-intensive than barium enema and conventional colonoscopy, and is inherently safer. Several studies demonstrate the ability of VC in the detection of colonic neoplastic lesions, not only large carcinomas, but also polyps. Currently, the most widely accepted clinical indication is incomplete or unsuccessful colonoscopy, which may be the result of redundant colon, patient intolerance to the procedure, spasm not resolving even with the use of spasmolytics, obstructing colo-rectal cancer. VC is also used to detect cancer in frail and immobile patients to avoid sedation during colonoscopy or the turning required during barium enema. The use of VC in patients under surveillance following colo-rectal cancer surgery is under investigation. Further studies are necessary in order to assess the cost-effectiveness of this approach. For colo-rectal cancer screening, a practical approach is to consider VC as a currently credible alternative screening method and as a reasonable alternative to the other colo-rectal cancer screening tests when a patient is unable or unwilling to undergo conventional colonoscopy. (orig.)

  20. Pediatric DXA: clinical applications

    International Nuclear Information System (INIS)

    Binkovitz, Larry A.; Sparke, Paul; Henwood, Maria J.

    2007-01-01

    Normal bone mineral accrual requires adequate dietary intake of calcium, vitamin D and other nutrients; hepatic and renal activation of vitamin D; normal hormone levels (thyroid, parathyroid, reproductive and growth hormones); and neuromuscular functioning with sufficient stress upon the skeleton to induce bone deposition. The presence of genetic or acquired diseases and the therapies that are used to treat them can also impact bone health. Since the introduction of clinical DXA in pediatrics in the early 1990s, there has been considerable investigation into the causes of low bone mineral density (BMD) in children. Pediatricians have also become aware of the role adequate bone mass accrual in childhood has in preventing osteoporotic fractures in late adulthood. Additionally, the availability of medications to improve BMD has increased with the development of bisphosphonates. These factors have led to the increased utilization of DXA in pediatrics. This review summarizes much of the previous research regarding BMD in children and is meant to assist radiologists and clinicians with DXA utilization and interpretation. (orig.)

  1. Problems of early clinical diagnostics of pseudoexfoliation syndrome

    Directory of Open Access Journals (Sweden)

    A. Yu. Brezhnev

    2012-01-01

    Full Text Available Purpose: to study the informativeness of pseudoexfoliation syndrome (PES signs for early diagnosis improvement.Methods: 250 patients with PES were included in the study. Exclusion criteria consisted of aphakia, pseudophakia, previous eye surgery and diseases which can complicate PES diagnostics (uveitis, corneal pathology, ocular injury etc.. Each patient underwent complete ophthalmic examination, including slit-lamp examination under mydriasis, gonioscopy. Confocal microscopy was used as an additional diagnostic method in several patients (Confoscan-4, Nidek.Results: Pseudoexfoliation material was found at the pupillary margin in 64.8% of patients, and on the lens capsule (central disc in 71% of the test subjects. Peripheral depositions were present in almost all PES patients under mydriasis. Pupil dilation has been allowed to establish the diagnosis of PES additionally in 16% of patients. At the «mini-PES»-stage PES material was most frequently found in the superior-nasal quadrant of lens capsule (85.6%. Clinical asymmetry of several signs (pupil diameter, anterior chamber angle pigmentation, IOP level should be taken into consideration in early PES diagnostics.Conclusion: Examination under mydriasis and knowledge of PES micro-signs in some cases has been allowed to suspect PESeven at the preclinical stage.

  2. Flat detectors and their clinical applications

    International Nuclear Information System (INIS)

    Spahn, Martin

    2005-01-01

    Diagnostic and interventional flat detector X-ray systems are penetrating the market in all application segments. First introduced in radiography and mammography, they have conquered cardiac and general angiography and are getting increasing attention in fluoroscopy. Two flat detector technologies prevail. The dominating method is based on an indirect X-ray conversion process, using cesium iodide scintillators. It offers considerable advantages in radiography, angiography and fluoroscopy. The other method employs a direct converter such as selenium which is particularly suitable for mammography. Both flat detector technologies are based on amorphous silicon active pixel matrices. Flat detectors facilitate the clinical workflow in radiographic rooms, foster improved image quality and provide the potential to reduce dose. This added value is based on their large dynamic range, their high sensitivity to X-rays and the instant availability of the image. Advanced image processing is instrumental in these improvements and expand the range of conventional diagnostic methods. In angiography and fluoroscopy the transition from image intensifiers to flat detectors is facilitated by ample advantages they offer, such as distortion-free images, excellent coarse contrast, large dynamic range and high X-ray sensitivity. These characteristics and their compatibility with strong magnetic fields are the basis for improved diagnostic methods and innovative interventional applications. (orig.)

  3. Echolalia: issues and clinical applications.

    Science.gov (United States)

    Schuler, A L

    1979-11-01

    Echolalic behaviors have been reported within the context of various pathologies but have remained poorly defined. Consequently, it is not easy to determine whether and to what extent normal repetition can be separated from pathological echoing. Hence, it is unclear whether the occurrence of echolalic behavior may be useful for differential diagnostic purposes. Also, much room is left for controversies about the clinical management of echolalic behavior. This article reviews the various conditions associated with echolalia and the role of repetitions in normal language behavior. Suggestions are made in terms of the various dimensions along which echolalic behavior should be assessed, as well as of the desirability of particular intervention techniques.

  4. [Usher syndrome: clinical features, diagnostic options, and therapeutic prospects].

    Science.gov (United States)

    Seeliger, M W; Fischer, M D; Pfister, M

    2009-06-01

    Usher syndrome denotes a clinically and genetically heterogeneous combination of retinitis pigmentosa and sensorineural deafness. The division into subtypes I, II, and III is based on the degree of hearing loss: Type I is characterized by deafness from birth together with ataxia and retarded motor development, type II by a stationary deafness of a moderate degree, and type III by a progressive deafness with adult onset. In Germany, Usher syndrome currently bears particular relevance because in January 2009 a new compulsory screening of auditory function in newborn infants was introduced. Consequently, it can be expected that a higher number of patients with Usher syndrome will be identified in early childhood and referred to ophthalmologists. The focus of this work is to introduce the typical clinical picture of Usher syndrome, summarize diagnostic options, and give an overview of therapeutic strategies.

  5. Implications of caries diagnostic strategies for clinical management decisions

    DEFF Research Database (Denmark)

    Baelum, Vibeke; Hintze, Hanne; Wenzel, Ann

    2012-01-01

    -specificity) were calculated for each diagnostic strategy. RESULTS: Visual-tactile examination provided a true-positive rate of 34.2% and a false-positive rate of 1.5% for the detection of a cavity. The combination of a visual-tactile and a radiographic examination using the lesion in dentin threshold......OBJECTIVES: In clinical practice, a visual-tactile caries examination is frequently supplemented by bitewing radiography. This study evaluated strategies for combining visual-tactile and radiographic caries detection methods and determined their implications for clinical management decisions...... and cavitated lesions while the radiographic examination determined lesion depth. Direct inspection of the surfaces following tooth separation for the presence of cavitated or noncavitated lesions was the validation method. The true-positive rate (i.e. the sensitivity) and the false-positive rate (i.e. 1...

  6. Diagnostic accuracy of clinical dehydration scales in children.

    Science.gov (United States)

    Falszewska, Anna; Dziechciarz, Piotr; Szajewska, Hania

    2017-08-01

    The aim of this study was to evaluate the diagnostic accuracy of the Clinical Dehydration Scale (CDS), the World Health Organization (WHO) scale, and the Gorelick scale for dehydration assessment in children. A prospective, observational study was carried out between October 2014 and December 2016. Eligible participants were children aged 1 month to 5 years with acute diarrhea. After hospital admission, each patient's weight was recorded and the degree of dehydration based on three scales was assessed. The reference standard was the percentage weight change between the discharge and admission weights. The main outcomes were the sensitivity, specificity, positive likelihood ratio (LR), and negative LR. Of 128 children enrolled in the study, complete data were available from 118 patients for analysis. Most of children presented with no or mild dehydration. Only the CDS showed limited value in confirming a diagnosis of dehydration ≥6% (positive LR 3.9, 95% CI 1.1 to 9.1), with no value in ruling it out (negative LR 0.6, 95% CI 0.2 to 0.99). In our cohort, the CDS was of limited diagnostic value in ruling in severe dehydration in children with acute gastroenteritis. The WHO and Gorelick scales were not helpful in the assessment of dehydration. What is Known : • Treatment of acute gastroenteritis (AGE) is based on assessing and correcting the degree of dehydration. • Several scales combining various signs and symptoms have been developed, including the Clinical Dehydration Scale (CDS), and the World Health Organization (WHO) scale, and the Gorelick scale. None of these scales is internationally accepted for best accuracy in diagnosing dehydration in children. What is New: • The CDS was of limited diagnostic value in ruling in severe dehydration in children with AGE. • The WHO and Gorelick scales were not helpful in the assessment of dehydration.

  7. Late-onset hypogonadism: etiology, clinical features, diagnostics, treatment

    Directory of Open Access Journals (Sweden)

    E. Yu. Pashkova

    2015-04-01

    Full Text Available In a critical review of the literature current data concerning etiology, clinical features, diagnostics, treatment of late-onset hypogonadism (LOH are given. LOH is a multidisciplinary problem, because a patient with LOH can have osteoporosis, anemia, depression, obesity, diabetes mellitus, erectile dysfunction. Sometimes it is hard to realize that all this complaints are symptoms of LOH. LOH has a negative impact on a patient,s quality of life and it,s impossible to help without androgen replacement therapy. Furthermore doctors often have doubts about testosterone replacement therapy safety because of lack of accurate information. In a convenient for medical practitioners form clinical and laboratory diagnostic criteria of LOH are presented together with formulas for conversion from one measurement unit of main sex hormones into another. Based on latest ISSAM guidelines (International Society for the Study of the Aging Male modern treatment options of LOH are summarized, full information about available testosterone preparations (oral, transdermal, injectable with comparative analysis of advantages and disadvantages of each is given. A full description of indications and contraindications for androgen replacement treatment is presented, also treatment regimen and medical supervision algorithm during treatment are described. 

  8. Late-onset hypogonadism: etiology, clinical features, diagnostics, treatment

    Directory of Open Access Journals (Sweden)

    E. Yu. Pashkova

    2015-01-01

    Full Text Available In a critical review of the literature current data concerning etiology, clinical features, diagnostics, treatment of late-onset hypogonadism (LOH are given. LOH is a multidisciplinary problem, because a patient with LOH can have osteoporosis, anemia, depression, obesity, diabetes mellitus, erectile dysfunction. Sometimes it is hard to realize that all this complaints are symptoms of LOH. LOH has a negative impact on a patient,s quality of life and it,s impossible to help without androgen replacement therapy. Furthermore doctors often have doubts about testosterone replacement therapy safety because of lack of accurate information. In a convenient for medical practitioners form clinical and laboratory diagnostic criteria of LOH are presented together with formulas for conversion from one measurement unit of main sex hormones into another. Based on latest ISSAM guidelines (International Society for the Study of the Aging Male modern treatment options of LOH are summarized, full information about available testosterone preparations (oral, transdermal, injectable with comparative analysis of advantages and disadvantages of each is given. A full description of indications and contraindications for androgen replacement treatment is presented, also treatment regimen and medical supervision algorithm during treatment are described. 

  9. Molecular biology applications to infectious diseases diagnostic

    International Nuclear Information System (INIS)

    2001-01-01

    This project goes directed to the applications of the techniques of molecular biology in hepatitis virus.A great advance of these techniques it allows its application to the diagnose molecular and it becomes indispensable to have these fundamental tools in the field of the Health Public for the detection precocious, pursuit of the treatment, the one predicts and the evolution of the patient hepatitis bearing virus technical.Use of molecular biology to increase the handling and the control of the patients with hepatitis B and C and to detect an adult numbers of positive cases by means of the training and integration of all the countries participating.Implement the technique of PCR to identify the virus of the hepatitis B and C,implement quantification methods and genotipification for these virus

  10. Panoramic radiography and its diagnostic application

    International Nuclear Information System (INIS)

    Koseki, Yonoshin

    1971-01-01

    Panoramic radiography is a term that is applied to the radiographic techniques which record is the dental arches and related structures on one or two extraoral films. It consists of two methods, one using the intraoral anode, and the other employing tomography. Because of an increase in practical application, about 10 kinds of panoramic dental X-ray units were commercially available in U.S.A.

  11. X-ray application in diagnostics and therapeutics

    International Nuclear Information System (INIS)

    Braun, H.

    1975-01-01

    The lecture gives a general survey on the present possibilities of application of X-rays and radio-isotopes in medical diagnostics and therapeutics. The possibility of decreasing the radiation exposure by using image intensifiers and television is particularly indicated. The advantages of scintiscanning in diagnostics are presented by means of a series of examples. The increasing significance of telecurie equipment and particle accelerators are refered to in therapeutics. Finally, the radiation risk due to the medical application of radiation to the patient and the personnel is discussed and compared to the natural radiation exposure. (ORU/LH) [de

  12. Density dependence of line intensities and application to plasma diagnostics

    International Nuclear Information System (INIS)

    Masai, Kuniaki.

    1993-02-01

    Electron density dependence of spectral lines are discussed in view of application to density diagnostics of plasmas. The dependence arises from competitive level population processes, radiative and collisional transitions from the excited states. Results of the measurement on tokamak plasmas are presented to demonstrate the usefulness of line intensity ratios for density diagnostics. Also general characteristics related to density dependence are discussed with atomic-number scaling for H-like and He-like systems to be helpful for application to higher density plasmas. (author)

  13. Laser beam diagnostics for metalworking applications

    International Nuclear Information System (INIS)

    Ramos, T.J.; Lingenfelter, A.C.

    1984-01-01

    The Materials Fabrication Division of Lawrence Livermore National Laboratory (LLNL) has three pulsed Nd-YAG lasers dedicated to metalworking. The units are used in a job shop primarily for welding. They also have a number of applications requiring cutting and drilling capability. Each of these metalworking operations requires somewhat different laser beam characteristics. As most investigators have found, the mode of the laser beam and the mode stability are the key variables which must be controlled if optimum results are to be achieved. The authors use several techniques to observe and measure these variables, i.e. Charge Couple Device (CCD) Camera, Thermal Image Plate and thermal-sensitive paper

  14. Clinical Application of Nape Acupuncture

    Institute of Scientific and Technical Information of China (English)

    HUA Xiao-yin; CUI Yi-jun

    2003-01-01

    @@ Nape Acupuncture refers to an acupuncture method at nuchal region. It was initiated and applied in clinic by Dr. HUA Yan-ling from Shanghai Research Institute of Acupuncture and Meridian and it can be used for treating diseases of nervous, circulatory and motor systems. Especially, it is more effective for brain-origin diseases. The author ever studied this acupuncture method from Dr. Hua and found it was effective according to clinical application. Now several typical cases are reported as follows.

  15. Applications of nanomaterials in sensors and diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Tuantranont, Adisorn (ed.) [National Electronics and Computer Technology Center (NECTEC), Pathumthani (Thailand). Nanoelectronics and MEMS Laboratory

    2013-11-01

    Recent progress in the synthesis of nanomaterials and our fundamental understanding of their properties has led to significant advances in nanomaterial-based gas, chemical and biological sensors. Leading experts around the world highlight the latest findings on a wide range of nanomaterials including nanoparticles, quantum dots, carbon nanotubes, molecularly imprinted nanostructures or plastibodies, nanometals, DNA-based structures, smart nanomaterials, nanoprobes, magnetic nanomaterials, organic molecules like phthalocyanines and porphyrins, and the most amazing novel nanomaterial, called graphene. Various sensing techniques such as nanoscaled electrochemical detection, functional nanomaterial-amplified optical assays, colorimetry, fluorescence and electrochemiluminescence, as well as biomedical diagnosis applications, e.g. for cancer and bone disease, are thoroughly reviewed and explained in detail. This volume will provide an invaluable source of information for scientists working in the field of nanomaterial-based technology as well as for advanced students in analytical chemistry, biochemistry, electrochemistry, material science, micro- and nanotechnology.

  16. Updated clinical diagnostic criteria for sporadic Creutzfeldt-Jakob disease

    Science.gov (United States)

    Kallenberg, K.; Summers, D. M.; Romero, C.; Taratuto, A.; Heinemann, U.; Breithaupt, M.; Varges, D.; Meissner, B.; Ladogana, A.; Schuur, M.; Haik, S.; Collins, S. J.; Jansen, Gerard H.; Stokin, G. B.; Pimentel, J.; Hewer, E.; Collie, D.; Smith, P.; Roberts, H.; Brandel, J. P.; van Duijn, C.; Pocchiari, M.; Begue, C.; Cras, P.; Will, R. G.; Sanchez-Juan, P.

    2009-01-01

    Several molecular subtypes of sporadic Creutzfeldt–Jakob disease have been identified and electroencephalogram and cerebrospinal fluid biomarkers have been reported to support clinical diagnosis but with variable utility according to subtype. In recent years, a series of publications have demonstrated a potentially important role for magnetic resonance imaging in the pre-mortem diagnosis of sporadic Creutzfeldt–Jakob disease. Magnetic resonance imaging signal alterations correlate with distinct sporadic Creutzfeldt–Jakob disease molecular subtypes and thus might contribute to the earlier identification of the whole spectrum of sporadic Creutzfeldt–Jakob disease cases. This multi-centre international study aimed to provide a rationale for the amendment of the clinical diagnostic criteria for sporadic Creutzfeldt–Jakob disease. Patients with sporadic Creutzfeldt–Jakob disease and fluid attenuated inversion recovery or diffusion-weight imaging were recruited from 12 countries. Patients referred as ‘suspected sporadic Creutzfeldt–Jakob disease’ but with an alternative diagnosis after thorough follow up, were analysed as controls. All magnetic resonance imaging scans were assessed for signal changes according to a standard protocol encompassing seven cortical regions, basal ganglia, thalamus and cerebellum. Magnetic resonance imaging scans were evaluated in 436 sporadic Creutzfeldt–Jakob disease patients and 141 controls. The pattern of high signal intensity with the best sensitivity and specificity in the differential diagnosis of sporadic Creutzfeldt–Jakob disease was identified. The optimum diagnostic accuracy in the differential diagnosis of rapid progressive dementia was obtained when either at least two cortical regions (temporal, parietal or occipital) or both caudate nucleus and putamen displayed a high signal in fluid attenuated inversion recovery or diffusion-weight imaging magnetic resonance imaging. Based on our analyses, magnetic

  17. Molecular Recognition Units: Design and diagnostic applications

    International Nuclear Information System (INIS)

    Alvarez, V.L.; Radcliffe, R.D.; Coughlin, D.J.; Lopes, A.D.; Rodwell, J.D.

    1992-01-01

    Molecular Recognition Units (MRUs), small peptides derived from complementarity-determining region (CDR) of IgM antibodies, can mimic the recognition site found in the antibody. One example of an MRU fusion peptide designed to image thrombi was derived from PAC 1.1, an IgM monoclonal antibody specific for the GPIIb/IIa receptor on platelets. The peptide sequence from the third CDR of the heavy chain was engineered for optimal binding activity and synthesized with a metal-binding peptide sequence. After labeling with 99m-Tc, the peptides were injected into either animal models of experimentally induced thrombi in order to determine their effectiveness in imaging model thrombi. Data are presented which demonstrate enhanced binding with open-quotes tandem repeatsclose quotes of the MRU domain and no loss of activity after incorporation of the metal-binding domain. These studies have led to a clinical candidate consisting of 17 amino acids. Extension of this concept to other MRUs and fusion peptides is also discussed

  18. Recent applications of nuclear medicine in diagnostics: II part

    Directory of Open Access Journals (Sweden)

    Giorgio Treglia

    2013-04-01

    Full Text Available Introduction: Positron-emission tomography (PET and single photon emission computed tomography (SPECT are effective diagnostic imaging tools in several clinical settings. The aim of this article (the second of a 2-part series is to examine some of the more recent applications of nuclear medicine imaging techniques, particularly in the fields of neurology, cardiology, and infection/inflammation. Discussion: A review of the literature reveals that in the field of neurology nuclear medicine techniques are most widely used to investigate cognitive deficits and dementia (particularly those associated with Alzheimer disease, epilepsy, and movement disorders. In cardiology, SPECT and PET also play important roles in the work-up of patients with coronary artery disease, providing accurate information on the state of the myocardium (perfusion, metabolism, and innervation. White blood cell scintigraphy and FDG-PET are widely used to investigate many infectious/inflammatory processes. In each of these areas, the review discusses the use of recently developed radiopharmaceuticals, the growth of tomographic nuclear medicine techniques, and the ways in which these advances are improving molecular imaging of biologic processes at the cellular level.

  19. Different clinical presentations, diagnostic difficulties, and management of cecal duplication.

    Science.gov (United States)

    Temiz, Abdulkerim; Oğuzkurt, Pelin; Ezer, Semire Serin; İnce, Emine; Gezer, Hasan Özkan; Hiçsönmez, Akgün

    2013-03-01

    Cecal duplications (CDs) are very rare, representing 0.4% of all gastrointestinal duplications. This study evaluates the variable clinical presentations, imaging workup, and surgical management of CDs. The records of 7 patients who underwent surgery between April 2001 and December 2011 for CD were retrospectively reviewed. Sex, age, duration of complaints, diagnostic studies, surgical intervention, and pathologic findings were recorded. The median age was 8 months, and mean age was 1.65 ± 2.88 years. Complaints were abdominal pain, rectal bleeding, vomiting, cough and dyspnea, and a prenatally detected cystic mass. The patients were referred with the diagnosis of appendicular abscess, necrotizing enterocolitis, gastrointestinal lymphoma, and intraabdominal cystic mass. Abdominal distention, signs of peritonitis, substernal retraction, fullness at right lower quadrant, and normal findings were detected on physical examination. Diagnostic imaging included plain abdominal radiography (7), ultrasonography (7), computed tomography (3), and magnetic resonance imaging (2). A cystic mass was reported on radiologic studies in 6 patients and appendicular abscess in 1. Cyst and cecum were resected, ileocolostomy was performed in 6 patients, and cyst excision was performed in 1. The diagnosis of duplication cyst was made by pathologic examination in all patients. Cecal duplications may be detected incidentally; however, they may mimic appendicular abscess, a tumor mass, or necrotizing enterocolitis. Whether cystic lesions are symptomatic, they should be excised when detected because of possible complications. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Pulmonary embolism. Clinical relevance, requirements for diagnostic and therapeutic strategies

    International Nuclear Information System (INIS)

    Nowak, F.G.; Halbfass, P.; Hoffmann, E.

    2007-01-01

    In the population the annual incidence of pulmonary embolism amounts to 1.3-2.8 per 1000 at the age of 65-89 years. Mortality reaches about 17% within the first 3 months. Acute pulmonary embolism is characterized by an increase in pulmonary arterial pressure and an impairment of the pulmonary gas exchange. Elevation of the right cardiac pressure up to right heart decompensation may follow. In addition, hypoxemia, hyperventilation, dead space ventilation, right to left shunting, bronchoconstriction, and vasoconstriction may occur. Clinical examination, ECG, laboratory findings such as elevated D-dimer, blood gas analysis, ultrasound examination of the veins of the lower extremities, and transthoracic echocardiography are acutely available diagnostic methods of an emergency department. In addition, extensive diagnostic procedures like pulmonary scintigraphy and pulmonary angiography may be required. The aim is to get a definite diagnosis as quickly as possible to direct therapy. In acute pulmonary embolism with cardiac shock, monitoring and stabilization of the circulatory function as well as an appropriate anticoagulant therapy are essential. In some cases surgery or a local fibrinolytic intervention is indicated. (orig.) [de

  1. Diagnostics and biomedical applications of radiofrequency plasmas

    International Nuclear Information System (INIS)

    Lazović, Saša

    2012-01-01

    In this paper we present spatial profiles of ion and atomic oxygen concentrations in a large scale cylindrical 13.56 MHz capacitively coupled plasma low pressure reactor suitable for indirect biomedical applications (like treatment of textile to increase antibacterial properties) and direct (treatment of seeds of rare and protected species). Such reactor can easily be used for the sterilization of medical instruments by removing bacteria, spores, prions and fungi as well. We also discuss electrical properties of the system based on the signals obtained by the derivative probes and show the light emission profiles close to the sample platform. In the case of seeds treatment, the desired effect is to plasma etch the outer shell of the seed which will lead to the easier nutrition and therefore increase of the germination. In the case of textile treatment the functionalization is done by bounding atomic oxygen to the surface. It appears that antibacterial properties of the textile are increased by incorporating nanoparticles to the fibres which can successfully be done after the plasma treatment. From these two examples it is obvious that the balance of ion and atomic oxygen concentrations as well as proper choice of ion energy and power delivered to the plasma direct the nature of the plasma treatment.

  2. Knowledge is not enough to solve the problems – The role of diagnostic knowledge in clinical reasoning activities

    Directory of Open Access Journals (Sweden)

    Jan Kiesewetter

    2016-11-01

    Full Text Available Abstract Background Clinical reasoning is a key competence in medicine. There is a lack of knowledge, how non-experts like medical students solve clinical problems. It is known that they have difficulties applying conceptual knowledge to clinical cases, that they lack metacognitive awareness and that higher level cognitive actions correlate with diagnostic accuracy. However, the role of conceptual, strategic, conditional, and metacognitive knowledge for clinical reasoning is unknown. Methods Medical students (n = 21 were exposed to three different clinical cases and instructed to use the think-aloud method. The recorded sessions were transcribed and coded with regards to the four different categories of diagnostic knowledge (see above. The transcripts were coded using the frequencies and time-coding of the categories of knowledge. The relationship between the coded data and accuracy of diagnosis was investigated with inferential statistical methods. Results The use of metacognitive knowledge is correlated with application of conceptual, but not with conditional and strategic knowledge. Furthermore, conceptual and strategic knowledge application is associated with longer time on task. However, in contrast to cognitive action levels the use of different categories of diagnostic knowledge was not associated with better diagnostic accuracy. Conclusions The longer case work and the more intense application of conceptual knowledge in individuals with high metacognitive activity may hint towards reduced premature closure as one of the major cognitive causes of errors in medicine. Additionally, for correct case solution the cognitive actions seem to be more important than the diagnostic knowledge categories.

  3. Feline genetics: clinical applications and genetic testing.

    Science.gov (United States)

    Lyons, Leslie A

    2010-11-01

    DNA testing for domestic cat diseases and appearance traits is a rapidly growing asset for veterinary medicine. Approximately 33 genes contain 50 mutations that cause feline health problems or alterations in the cat's appearance. A variety of commercial laboratories can now perform cat genetic diagnostics, allowing both the veterinary clinician and the private owner to obtain DNA test results. DNA is easily obtained from a cat via a buccal swab with a standard cotton bud or cytological brush, allowing DNA samples to be easily sent to any laboratory in the world. The DNA test results identify carriers of the traits, predict the incidence of traits from breeding programs, and influence medical prognoses and treatments. An overall goal of identifying these genetic mutations is the correction of the defect via gene therapies and designer drug therapies. Thus, genetic testing is an effective preventative medicine and a potential ultimate cure. However, genetic diagnostic tests may still be novel for many veterinary practitioners and their application in the clinical setting needs to have the same scrutiny as any other diagnostic procedure. This article will review the genetic tests for the domestic cat, potential sources of error for genetic testing, and the pros and cons of DNA results in veterinary medicine. Highlighted are genetic tests specific to the individual cat, which are a part of the cat's internal genome. Copyright © 2010 Elsevier Inc. All rights reserved.

  4. From Clinical Symptoms to MR Imaging: Diagnostic Steps in Adenomyosis

    Directory of Open Access Journals (Sweden)

    H. Krentel

    2017-01-01

    Full Text Available Adenomyosis or endometriosis genitalis interna is a frequent benign disease of women in fertile age. It causes symptoms like bleeding disorders and dysmenorrhea and seems to have a negative effect on fertility. Adenomyosis can be part of a complex genital and extragenital endometriosis but also can be found as a solitary uterine disease. While peritoneal endometriosis can be easily diagnosed by laparoscopy with subsequent biopsy, the determination of adenomyosis is difficult. In the following literature review, the diagnostic methods clinical history and symptoms, gynecological examination, 2D and 3D transvaginal ultrasound, MRI, hysteroscopy, and laparoscopy will be discussed step by step in order to evaluate their predictive value in the diagnosis of adenomyosis.

  5. [Child sexual abuse. Epidemiology, clinical diagnostics, therapy, and prevention].

    Science.gov (United States)

    Fegert, J M; Hoffmann, U; Spröber, N; Liebhardt, H

    2013-02-01

    The article provides an overview of the research on sexual abuse and the current political developments in Germany. First, the terminology of sexual child abuse is discussed, followed by the presentation of epidemiological data. The section on diagnostics and therapy shows that--because of mostly nonspecific indicators--the diagnosis of child sexual abuse is very difficult to define. Child sexual abuse is discussed as a traumatic experience for children and adolescents with different psychiatric and physical diseases. Current studies have shown that especially cognitive behavioral therapeutic-oriented approaches are effective in curing posttraumatic stress disorders. Based on the new German Child Protection Act, the focus lies on the clarification of confidentiality for medical professionals and their right to consulting services for child protection. In conclusion, guidelines and minimum standards for a child prevention and protection model are presented as well as institutional recommendations addressed to all institutions (also clinical) that take care of or treat children and adolescents.

  6. Diagnostic clinical parasitology: IV. Identification of the blood parasites?

    Science.gov (United States)

    Garcia, L S; Voge, M

    1981-01-01

    This is the fourth article in a series of articles entitled "Diagnostic Clinical Parasitology" and contains information on the recovery and identification of human blood parasites. The organisms covered include those that cause the diseases malaria, babesiosis, leishmaniasis, and trypanosomiasis. Some of the filarial worms, which can be considered "blood parasites," have been discussed in the third article in the series, "Identification of the Helminths." Although some of these organisms may rarely be encountered in the laboratory in clinical specimens, they will probably have to be identified in proficiency testing specimens, some of which may not always be representative of patient clinical material. The differences between potential organism recovery from patients coming from endemic areas and from those individuals who become infected with no prior exposure to the organism will also be emphasized. Often, for a number of different reasons, organism recovery and subsequent identification may be more difficult than the textbook imply. It is very important for the technologist to recognize this fact, particularly when dealing with a possibly fatal infection, ie, Plasmodium falciparum.

  7. Diagnostic accuracy of clinical tests for the diagnosis of hip femoroacetabular impingement/labral tear

    DEFF Research Database (Denmark)

    Reiman, M P; Goode, A P; Cook, C E

    2015-01-01

    BACKGROUND: Surgery for hip femoroacetabular impingement/acetabular labral tear (FAI/ALT) is exponentially increasing despite lacking investigation of the accuracy of various diagnostic measures. Useful clinical utility of these measures is necessary to support diagnostic imaging and subsequent...

  8. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  9. Molecular diagnostics of lung cancer in the clinic.

    Science.gov (United States)

    Sholl, Lynette

    2017-10-01

    According to current practice guidelines, all patients with advanced non-small cell lung cancer (NSCLC) should undergo predictive biomarker testing. For squamous cell carcinoma patients, PD-L1 immunohistochemistry is indicated to select patients for immunotherapy in the first line. For lung adenocarcinoma, all patients with advanced disease should undergo testing for epidermal growth factor receptor ( EGFR ) mutations, ALK and ROS1 rearrangements, and PD-L1 expression to predict response to EGFR, ALK, or ROS1 targeted inhibitors or immunotherapy, respectively. Besides these, a number of other biomarkers are under clinical investigation as predictors of response to targeted therapies, including BRAF , ERBB2 , MET splice mutations and amplification, and RET rearrangements. Successful testing for this complex array of molecular targets demands careful coordination between proceduralists, pathologists and molecular laboratories to ensure proper tumor tissue handling following biopsy as well as judicious use of diagnostic immunohistochemistry. Even so, sample failure rates due to inadequate tumor tissue are high in practice, particularly when using sequential testing methods. Use of next generation sequencing (NGS) in clinical practice can enable detection of multiple targets and multiple alteration types (mutation, gene copy change, and rearrangement) simultaneously even with small amounts of input nucleic acids, thus increasing molecular testing success rates. In patients with an established lung cancer diagnosis but with prohibitively limited amounts of tumor tissue or who are experiencing relapse, analyses of circulating tumor DNA (ctDNA) from the plasma can serve as an alternate testing substrate, however the more limited clinical sensitivity of this approach must be taken into account. This review will explore the indications for and pitfalls of routine NGS and plasma genotyping in the clinic, including the intersection of these technologies.

  10. Opto-electronic DNA chip-based integrated card for clinical diagnostics.

    Science.gov (United States)

    Marchand, Gilles; Broyer, Patrick; Lanet, Véronique; Delattre, Cyril; Foucault, Frédéric; Menou, Lionel; Calvas, Bernard; Roller, Denis; Ginot, Frédéric; Campagnolo, Raymond; Mallard, Frédéric

    2008-02-01

    Clinical diagnostics is one of the most promising applications for microfluidic lab-on-a-chip or lab-on-card systems. DNA chips, which provide multiparametric data, are privileged tools for genomic analysis. However, automation of molecular biology protocol and use of these DNA chips in fully integrated systems remains a great challenge. Simplicity of chip and/or card/instrument interfaces is amongst the most critical issues to be addressed. Indeed, current detection systems for DNA chip reading are often complex, expensive, bulky and even limited in terms of sensitivity or accuracy. Furthermore, for liquid handling in the lab-on-cards, many devices use complex and bulky systems, either to directly manipulate fluids, or to ensure pneumatic or mechanical control of integrated valves. All these drawbacks prevent or limit the use of DNA-chip-based integrated systems, for point-of-care testing or as a routine diagnostics tool. We present here a DNA-chip-based protocol integration on a plastic card for clinical diagnostics applications including: (1) an opto-electronic DNA-chip, (2) fluid handling using electrically activated embedded pyrotechnic microvalves with closing/opening functions. We demonstrate both fluidic and electric packaging of the optoelectronic DNA chip without major alteration of its electronical and biological functionalities, and fluid control using novel electrically activable pyrotechnic microvalves. Finally, we suggest a complete design of a card dedicated to automation of a complex biological protocol with a fully electrical fluid handling and DNA chip reading.

  11. Dental diagnostic clinical instrument ('Canary') development using photothermal radiometry and modulated luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, R J; Sivagurunathan, K; Garcia, J; Matvienko, A; Mandelis, A [Center for Advanced Diffusion Wave Technologies (CADIFT), Department of Mechanical and Industrial Engineering, University of Toronto, 5 King' s College Road, Toronto, Ontario, M5S 3G8 (Canada); Abrams, S, E-mail: mandelis@mie.utoronto.c [Quantum Dental Technologies, 748 Briar Hill Avenue, Toronto, Ontario, M6B 1L3 (Canada)

    2010-03-01

    Since 1999, our group at the CADIFT, University of Toronto, has developed the application of Frequency Domain Photothermal Radiometry (PTR) and Luminescence (LUM) to dental caries detection. Various cases including artificial caries detection have been studied and some of the inherent advantages of the adaptation of this technique to dental diagnostics in conjunction with modulated luminescence as a dual-probe technique have been reported. Based on these studies, a portable, compact diagnostic instrument for dental clinic use has been designed, assembled and tested. A semiconductor laser, optical fibers, a thermoelectric cooled mid-IR detector, and a USB connected data acquisition card were used. Software lock-in amplifier techniques were developed to compute amplitude and phase of PTR and LUM signals. In order to achieve fast measurement and acceptable signal-to-noise ratio (SNR) for clinical application, swept sine waveforms were used. As a result sampling and stabilization time for each measurement point was reduced to a few seconds. A sophisticated software interface was designed to simultaneously record intra-oral camera images with PTR and LUM responses. Preliminary results using this instrument during clinical trials in a dental clinic showed this instrument could detect early caries both from PTR and LUM signals.

  12. Dental diagnostic clinical instrument (Canary) development using photothermal radiometry and modulated luminescence

    International Nuclear Information System (INIS)

    Jeon, R J; Sivagurunathan, K; Garcia, J; Matvienko, A; Mandelis, A; Abrams, S

    2010-01-01

    Since 1999, our group at the CADIFT, University of Toronto, has developed the application of Frequency Domain Photothermal Radiometry (PTR) and Luminescence (LUM) to dental caries detection. Various cases including artificial caries detection have been studied and some of the inherent advantages of the adaptation of this technique to dental diagnostics in conjunction with modulated luminescence as a dual-probe technique have been reported. Based on these studies, a portable, compact diagnostic instrument for dental clinic use has been designed, assembled and tested. A semiconductor laser, optical fibers, a thermoelectric cooled mid-IR detector, and a USB connected data acquisition card were used. Software lock-in amplifier techniques were developed to compute amplitude and phase of PTR and LUM signals. In order to achieve fast measurement and acceptable signal-to-noise ratio (SNR) for clinical application, swept sine waveforms were used. As a result sampling and stabilization time for each measurement point was reduced to a few seconds. A sophisticated software interface was designed to simultaneously record intra-oral camera images with PTR and LUM responses. Preliminary results using this instrument during clinical trials in a dental clinic showed this instrument could detect early caries both from PTR and LUM signals.

  13. Clinical-Diagnostic Features of Duchenne Muscular Dystrophy in Children

    Directory of Open Access Journals (Sweden)

    Umida T. Omonova

    2013-12-01

    Full Text Available Duchenne Muscular Dystrophy (DMD is a severe, progressive disease that affects about 1 out of every 5,000 male infants; this is the most destructive of all muscular dystrophies, which worsens rapidly. In this study, we performed a clinical analysis of 37 children with DMD. They ranged in age from 3 to 15 years, mean age being 7.8±0.48 years. The mean age at onset was 4.3±0.36 years and ranged from birth to 8 years. The biochemical examination included the determination of the serum levels of the following enzymes, AST, ALT, CPK-MM, and LDH. A genealogical analysis was conducted among 240 first-degree relatives of children with DMD. Electroneuromyography examination included registration of the biopotentials of the hand and foot muscles, measurement of the muscle response (M-wave and the late-evoked responses. The clinical-diagnostic features of DMD in children were characterized.

  14. Clinical diagnostic potentials of thyroid ultrasonography and scintigraphy; An evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Torizuka, Tatsuo; Kasagi, Kanji; Hatabu, Hiroto; Misaki, Takashi; Iida, Yasuhiro; Konishi, Junji (Kyoto Univ. (Japan). Hospital); Endo, Keigo

    1993-06-01

    This prospective study was designed to evaluate the potential contributions of high resolution ultrasonography (US) and Tc-99m scintigraphy in the routine diagnosis of thyroid disease. The diagnostic impacts of US and Tc-99m scintigraphy results in 177 patients visiting our thyroid clinic were assessed and scored according to the following criteria: when the information provided by either test supported, confirmed or changed the initial clinical diagnosis, they received scores of 2, 3 and 4 respectively, while score 1 was given when the test itself was useless for the differential diagnosis. US identified focal lesions that both palpation and scintigraphy had failed to detect in 14 (12.1%) of 116 patients with diffuse thyroid diseases, suggesting the necessity of Hashimoto's thyroiditis, adenoma, adenocarcinoma and adenomatous goiter, and vice versa in the diagnosis of hyperthyroid and euthyroid Graves's diseases. Thus, the advantages of US over scintigraphy for morphological evaluation were confirmed. US was particularly useful for the differential diagnosis of adenomatous goiter from Hashimoto's thyroiditis or a single nodular disease. In contrast, scintigraphy gave functional images, being especially helpful for the differential diagnosis of thyrotoxicosis. (author).

  15. Clinical applications of cells labelling

    International Nuclear Information System (INIS)

    Gonzalez, B.M.

    1994-01-01

    Blood cells labelled with radionuclides are reviewed and main applications are described. Red blood cell labelling by both random and specific principle. A table with most important clinical uses, 99mTc labelling of RBC are described pre tinning and in vivo reduction of Tc, in vitro labelling and administration of labelled RBC and in vivo modified technique. Labelled leucocytes with several 99mTc-complex radiopharmaceuticals by in vitro technique and specific monoclonal s for white cells(neutrofiles). Labelled platelets for clinical use and research by in vitro technique and in vivo labelling

  16. Application of diagnostics to determine motor operated valve operational readiness

    International Nuclear Information System (INIS)

    Eissenberg, D.M.

    1987-01-01

    ORNL has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor current signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment

  17. Autoimmune liver serology: current diagnostic and clinical challenges.

    Science.gov (United States)

    Bogdanos, Dimitrios-P; Invernizzi, Pietro; Mackay, Ian-R; Vergani, Diego

    2008-06-07

    Liver-related autoantibodies are crucial for the correct diagnosis and classification of autoimmune liver diseases (AiLD), namely autoimmune hepatitis types 1 and 2 (AIH-1 and 2), primary biliary cirrhosis (PBC), and the sclerosing cholangitis variants in adults and children. AIH-1 is specified by anti-nuclear antibody (ANA) and smooth muscle antibody (SMA). AIH-2 is specified by antibody to liver kidney microsomal antigen type-1 (anti-LKM1) and anti-liver cytosol type 1 (anti-LC1). SMA, ANA and anti-LKM antibodies can be present in de-novo AIH following liver transplantation. PBC is specified by antimitochondrial antibodies (AMA) reacting with enzymes of the 2-oxo-acid dehydrogenase complexes (chiefly pyruvate dehydrogenase complex E2 subunit) and disease-specific ANA mainly reacting with nuclear pore gp210 and nuclear body sp100. Sclerosing cholangitis presents as at least two variants, first the classical primary sclerosing cholangitis (PSC) mostly affecting adult men wherein the only (and non-specific) reactivity is an atypical perinuclear antineutrophil cytoplasmic antibody (p-ANCA), also termed perinuclear anti-neutrophil nuclear antibodies (p-ANNA) and second the childhood disease called autoimmune sclerosing cholangitis (ASC) with serological features resembling those of type 1 AIH. Liver diagnostic serology is a fast-expanding area of investigation as new purified and recombinant autoantigens, and automated technologies such as ELISAs and bead assays, become available to complement (or even compete with) traditional immunofluorescence procedures. We survey for the first time global trends in quality assurance impacting as it does on (1) manufacturers/purveyors of kits and reagents, (2) diagnostic service laboratories that fulfill clinicians' requirements, and (3) the end-user, the physician providing patient care, who must properly interpret test results in the overall clinical context.

  18. Opportunities and challenges associated with clinical diagnostic genome sequencing: a report of the Association for Molecular Pathology.

    Science.gov (United States)

    Schrijver, Iris; Aziz, Nazneen; Farkas, Daniel H; Furtado, Manohar; Gonzalez, Andrea Ferreira; Greiner, Timothy C; Grody, Wayne W; Hambuch, Tina; Kalman, Lisa; Kant, Jeffrey A; Klein, Roger D; Leonard, Debra G B; Lubin, Ira M; Mao, Rong; Nagan, Narasimhan; Pratt, Victoria M; Sobel, Mark E; Voelkerding, Karl V; Gibson, Jane S

    2012-11-01

    This report of the Whole Genome Analysis group of the Association for Molecular Pathology illuminates the opportunities and challenges associated with clinical diagnostic genome sequencing. With the reality of clinical application of next-generation sequencing, technical aspects of molecular testing can be accomplished at greater speed and with higher volume, while much information is obtained. Although this testing is a next logical step for molecular pathology laboratories, the potential impact on the diagnostic process and clinical correlations is extraordinary and clinical interpretation will be challenging. We review the rapidly evolving technologies; provide application examples; discuss aspects of clinical utility, ethics, and consent; and address the analytic, postanalytic, and professional implications. Copyright © 2012 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  19. Clinical applications of transient elastography

    Directory of Open Access Journals (Sweden)

    Kyu Sik Jung

    2012-06-01

    Full Text Available Chronic liver disease represents a major public health problem, accounting for significant morbidity and mortality worldwide. As prognosis and management depend mainly on the amount and progression of liver fibrosis, accurate quantification of liver fibrosis is essential for therapeutic decision-making and follow-up of chronic liver diseases. Even though liver biopsy is the gold standard for evaluation of liver fibrosis, non-invasive methods that could substitute for invasive procedures have been investigated during past decades. Transient elastography (TE, FibroScan® is a novel non-invasive method for assessment of liver fibrosis with chronic liver disease. TE can be performed in the outpatient clinic with immediate results and excellent reproducibility. Its diagnostic accuracy for assessment of liver fibrosis has been demonstrated in patients with chronic viral hepatitis; as a result, unnecessary liver biopsy could be avoided in some patients. Moreover, due to its excellent patient acceptance, TE could be used for monitoring disease progression or predicting development of liver-related complications. This review aims at discussing the usefulness of TE in clinical practice.

  20. Development in Diagnostics Application to Control Advanced Tokamak Plasma

    International Nuclear Information System (INIS)

    Koide, Y.

    2008-01-01

    For continuous operation expected in DEMO, all the plasma current must be non-inductively driven, with self-generated neoclassical bootstrap current being maximized. The control of such steady state high performance tokamak plasma (so-called 'Advanced Tokamak Plasma') is a challenge because of the strong coupling between the current density, the pressure profile and MHD stability. In considering diagnostic needs for the advanced tokamak research, diagnostics for MHD are the most fundamental, since discharges which violate the MHD stability criteria either disrupt or have significantly reduced confinement. This report deals with the development in diagnostic application to control advanced tokamak plasma, with emphasized on recent progress in active feedback control of the current profile and the pressure profile under DEMO-relevant high bootstrap-current fraction. In addition, issues in application of the present-day actuators and diagnostics for the advanced control to DEMO will be briefly addressed, where port space for the advanced control may be limited so as to keep sufficient tritium breeding ratio (TBR)

  1. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology (French Edition)

    International Nuclear Information System (INIS)

    2012-01-01

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  2. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology (Spanish Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  3. Proposed Diagnostic Criteria for the DSM-5 of Nonsuicidal Self-Injury in Female Adolescents: Diagnostic and Clinical Correlates

    Directory of Open Access Journals (Sweden)

    Tina In-Albon

    2013-01-01

    Full Text Available Nonsuicidal self-injury (NSSI is included as conditions for further study in the DSM-5. Therefore, it is necessary to investigate the proposed diagnostic criteria and the diagnostic and clinical correlates for the validity of a diagnostic entity. The authors investigated the characteristics of NSSI disorder and the proposed diagnostic criteria. A sample of 73 female inpatient adolescents and 37 nonclinical adolescents (aged 13 to 19 years was recruited. Patients were classified into 4 groups (adolescents with NSSI disorder, adolescents with NSSI without impairment/distress, clinical controls without NSSI, and nonclinical controls. Adolescents were compared on self-reported psychopathology and diagnostic cooccurrences. Results indicate that adolescents with NSSI disorder have a higher level of impairment than adolescents with other mental disorders without NSSI. Most common comorbid diagnoses were major depression, social phobia, and PTSD. There was some overlap of adolescents with NSSI disorder and suicidal behaviour and borderline personality disorder, but there were also important differences. Results further suggest that the proposed DSM-5 diagnostic criteria for NSSI are useful and necessary. In conclusion, NSSI is a highly impairing disorder characterized by high comorbidity with various disorders, providing further evidence that NSSI should be a distinct diagnostic entity.

  4. Applications of Next-Generation Sequencing Technologies to Diagnostic Virology

    Directory of Open Access Journals (Sweden)

    Giorgio Palù

    2011-11-01

    Full Text Available Novel DNA sequencing techniques, referred to as “next-generation” sequencing (NGS, provide high speed and throughput that can produce an enormous volume of sequences with many possible applications in research and diagnostic settings. In this article, we provide an overview of the many applications of NGS in diagnostic virology. NGS techniques have been used for high-throughput whole viral genome sequencing, such as sequencing of new influenza viruses, for detection of viral genome variability and evolution within the host, such as investigation of human immunodeficiency virus and human hepatitis C virus quasispecies, and monitoring of low-abundance antiviral drug-resistance mutations. NGS techniques have been applied to metagenomics-based strategies for the detection of unexpected disease-associated viruses and for the discovery of novel human viruses, including cancer-related viruses. Finally, the human virome in healthy and disease conditions has been described by NGS-based metagenomics.

  5. Radiolabeled peptides: experimental and clinical applications

    International Nuclear Information System (INIS)

    Thakur, M.L.; Pallela, V.R.

    1998-01-01

    Radiolabeled receptor specific biomolecules hold unlimited potential in nuclear medicine. During the past few years much attention has been drawn to the development radiolabeled peptides for a variety of diagnostic applications, as well as for therapy of malignant tumors. Although only one peptide, In-111-DTPA-(D)-Phe 1 -octreotide, is available commercially for oncologic imaging, many more have been examined in humans with hematological disorders, and the early results appear to be promising. Impetus generated by these results have prompted investigators to label peptides with such radionuclides as Tc-99m, I-123, F-18, Cu-64, and Y-90. This review is intended to highlight the qualities of peptides, summarize the clinical results, and address some important issues associated with radiolabeling of highly potent peptides. While doing so, various methods of radiolabeling have been described, and their strengths and weaknesses have also been discussed. (author)

  6. Transcriptomics in cancer diagnostics: developments in technology, clinical research and commercialization.

    Science.gov (United States)

    Sager, Monica; Yeat, Nai Chien; Pajaro-Van der Stadt, Stefan; Lin, Charlotte; Ren, Qiuyin; Lin, Jimmy

    2015-01-01

    Transcriptomic technologies are evolving to diagnose cancer earlier and more accurately to provide greater predictive and prognostic utility to oncologists and patients. Digital techniques such as RNA sequencing are replacing still-imaging techniques to provide more detailed analysis of the transcriptome and aberrant expression that causes oncogenesis, while companion diagnostics are developing to determine the likely effectiveness of targeted treatments. This article examines recent advancements in molecular profiling research and technology as applied to cancer diagnosis, clinical applications and predictions for the future of personalized medicine in oncology.

  7. Applications of digital processing for noise removal from plasma diagnostics

    International Nuclear Information System (INIS)

    Kane, R.J.; Candy, J.V.; Casper, T.A.

    1985-01-01

    The use of digital signal techniques for removal of noise components present in plasma diagnostic signals is discussed, particularly with reference to diamagnetic loop signals. These signals contain noise due to power supply ripple in addition to plasma characteristics. The application of noise canceling techniques, such as adaptive noise canceling and model-based estimation, will be discussed. The use of computer codes such as SIG is described. 19 refs., 5 figs

  8. CLINICAL PICTURE, DIAGNOSTICS AND TREATMENT OF GIARDIASIS IN CHILDREN

    Directory of Open Access Journals (Sweden)

    E.A. Kornienko

    2009-01-01

    Full Text Available According to the WHO, giardiasis incidence rate in children in the world is 15 to 20%. In Russia, over 130,000 cases of giardiasis are registered annually, of which children under 14 years account for more than 70%. The study of 124 children with giardiasis conducted by the authors has shown that giardiasis in children always triggers development of chronic duodenitis, in 55% of cases that coupled with lymphostasis, in 45% — that with atrophy of duodenum mucous lining. In 40% of cases, chronic duodenitis with giardiasis is accompanied with duodenogastric reflux, in 88% — with development of lactase deficiency, in 81% — by functional biliary system distress and in all cases with intestinal tract microbiocenosis distress. Along with clinical manifestations of the disease, the researchers have studied immunological modifications in children with giardiasis, and have evaluated the information content of various diagnostic techniques, efficiency of medication. The authors have demonstrated that mono therapy with any of anti giardiasis drugs (metronidazole, nifuratel, albendozole has low efficiency. Saccharomyces boulardii have a powerful comprehensive effect on many links of giardiasis pathogenesis.Key words: giardiasis, infestation, scatoscopy, Saccharomyces boulardii.

  9. BRIEF REPORT: Beyond Clinical Experience: Features of Data Collection and Interpretation That Contribute to Diagnostic Accuracy

    Science.gov (United States)

    Nendaz, Mathieu R; Gut, Anne M; Perrier, Arnaud; Louis-Simonet, Martine; Blondon-Choa, Katherine; Herrmann, François R; Junod, Alain F; Vu, Nu V

    2006-01-01

    BACKGROUND Clinical experience, features of data collection process, or both, affect diagnostic accuracy, but their respective role is unclear. OBJECTIVE, DESIGN Prospective, observational study, to determine the respective contribution of clinical experience and data collection features to diagnostic accuracy. METHODS Six Internists, 6 second year internal medicine residents, and 6 senior medical students worked up the same 7 cases with a standardized patient. Each encounter was audiotaped and immediately assessed by the subjects who indicated the reasons underlying their data collection. We analyzed the encounters according to diagnostic accuracy, information collected, organ systems explored, diagnoses evaluated, and final decisions made, and we determined predictors of diagnostic accuracy by logistic regression models. RESULTS Several features significantly predicted diagnostic accuracy after correction for clinical experience: early exploration of correct diagnosis (odds ratio [OR] 24.35) or of relevant diagnostic hypotheses (OR 2.22) to frame clinical data collection, larger number of diagnostic hypotheses evaluated (OR 1.08), and collection of relevant clinical data (OR 1.19). CONCLUSION Some features of data collection and interpretation are related to diagnostic accuracy beyond clinical experience and should be explicitly included in clinical training and modeled by clinical teachers. Thoroughness in data collection should not be considered a privileged way to diagnostic success. PMID:17105525

  10. Clinical applications of immunoglobulin: update

    Directory of Open Access Journals (Sweden)

    Marcia Cristina Zago Novaretti

    2011-06-01

    Full Text Available Human immunoglobulin is the most used blood product in the clinical practice. Immunoglobulin applications have increased quickly since the elucidation of its immunomodulatory and antiinflammatory properties which turned this blood product into a precious tool in the treatment of numerous diseases that present with humoral immune deficiency or that cause immune system dysfunction. Currently, the approved indications for Ig are: primary immunodeficiencies, secondary immunodeficiencies (multiple myeloma or chronic lymphoid leukemia, Kawasaki syndrome, immune thrombocytopenic purpura, Guillain Barré syndrome, graft-versus-host disease following bone marrow transplantation and repeat infections in HIV children. On the other hand, there are numerous "off-label" indications of immunoglobulin, which represent 20-60% of all clinical applications of this drug. It is important to study all these indications and, above all, the scientific evidence for its use, in order to provide patients with a new therapeutic option without burdening the health system. This review results from a wide selection of papers identified in the Pubmed and Lilacs scientific electronic databases. A group of descriptors were used from human immunoglobulin to the names of each disease that immunoglobulin is clinically applied. Our main objective is to list the numerous indications of immunoglobulin, both authorized and "off-label" and to analyze these indications in the light of the most recent scientific evidence.

  11. Development and Diagnostic Accuracy of the Screening of the Dimensional Clinical Personality Inventory

    Directory of Open Access Journals (Sweden)

    Lucas de Francisco Carvalho

    Full Text Available Abstract: The assessment of personality disorders assumes unquestioned clinical relevance when considering the prevalence rates in the general population. Tests assessing the typical pathological traits of these disorders has been adapted to and developed in Brazil. However, there is a gap in the country of screening tools for personality disorders. Screening tools are designed to allow a fast and informative application on the likelihood of a positive diagnosis, where the consequence should be conveyed to a diagnostic assessment. Using as a base the Dimensional Clinical Personality Inventory (IDCP, developed at the national level, the objective of this research was to develop a screening tool for personality disorders, as well as investigate its diagnostic accuracy. The study included 1,196 people, aging between 18 and 73 years (M = 26.32, SD = 8.69, and 64.1% female. The sample was divided into clinical and non-clinical group. We used an empirical approach based on criteria for selection of items similar to those adopted in the development of Minnesota Multiphasic Personality Inventory was used (MMPI. The logistic regression analysis and also the calculation of Cohen's d indicated the items that best discriminate against people with personality disorders and those without this diagnosis. We achieved a final set of 15 items with satisfactory sensitivity and specificity for screening test. We discusses the strengths and limitations of screening version of the IDCP and guidelines for further study.

  12. Clinical diagnostic system using a small cyclotron for medical use

    International Nuclear Information System (INIS)

    Yonekura, Y.; Magata, Y.; Konishi, J.

    1990-01-01

    Since a small cyclotron and a positron emission tomography (PET) scanner have been installed at the Kyoto University Hospital in 1983, a great deal of effort has been directed to the clinical application of the PET-cyclotron system. This paper outlines the experience with PET in the clinical setting, including the facility, equipments and staff involved, weekly schedule, typical clinical protocols, and some results from the patients. The system consists of small cyclotron for production of the short-lived positron emitting radionuclides, fully automated synthesis system for labeling various compounds, scanning for measurement of radioactivities, and data analysis system for calculating physiological parameters. A resolving cylinder target system with eight smaller cylinders is equipped for production of C-11, N-13, O-15, and F-18. Labeled compounds are quickly delivered to the PET scanner room by two systems--the continuous delivery system for the labeled gas and the rapid delivery system for the liquid compounds by compressed air. A PET scanner devoted for clinical studies is a multislice whole-body PET scanner. Ten PET studies are performed weekly on the average for measuring blood flow and oxygen and glucose metabolism in the brain, blood flow and glucose and fatty acid metabolism in the heart, blood flow and amino acid uptake in the pancreas, lung ventilation, and tumor glucose metabolism. The availability of PET-cyclotron system is still limited in view of cost. The previous clinical studies suggest the contribution of PET to the the understanding of the mechanism of disease pathophysiology. (N.K.)

  13. Teleultrasound: Historical Perspective and Clinical Application

    Directory of Open Access Journals (Sweden)

    Adilson Cunha Ferreira

    2015-01-01

    Full Text Available The health care of patients in rural or isolated areas is challenged by the scarcity of local resources, limited patient access to doctors and hospitals, and the lack of specialized professionals. This has led to a new concept in telemedicine: teleultrasonography (or teleultrasound, which permits ultrasonographic diagnoses to be performed remotely. Telemedicine and teleultrasonography are effective in providing diagnostic imaging services to these populations and reduce health care costs by decreasing the number and duration of hospitalizations and reducing unnecessary surgical procedures. This is a narrative review to present the potential clinical applications of teleultrasonography in clinical practice. The results indicate that although barriers persist for implementing teleultrasonography in a more universal and routine way, advances in telecommunications, Internet bandwidth, and the high resolution currently available for portable ultrasonography suggest teleultrasonography applications will continue to expand. Teleultrasound appears to be a valuable addition to remote medical care for isolated populations with limited access to tertiary healthcare facilities and also a useful tool for education and training.

  14. Clinical application of bio ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Anu, Sharma, E-mail: issaranu@gmail.com; Gayatri, Sharma, E-mail: sharmagayatri@gmail.com [Department of Chemistry, Govt. College of Engineering & Technology, Bikaner, Rajasthan (India)

    2016-05-06

    Ceramics are the inorganic crystalline material. These are used in various field such as biomedical, electrical, electronics, aerospace, automotive and optical etc. Bio ceramics are the one of the most active areas of research. Bio ceramics are the ceramics which are biocompatible. The unique properties of bio ceramics make them an attractive option for medical applications and offer some potential advantages over other materials. During the past three decades, a number of major advances have been made in the field of bio ceramics. This review focuses on the use of these materials in variety of clinical scenarios.

  15. Clinical application of bio ceramics

    International Nuclear Information System (INIS)

    Anu, Sharma; Gayatri, Sharma

    2016-01-01

    Ceramics are the inorganic crystalline material. These are used in various field such as biomedical, electrical, electronics, aerospace, automotive and optical etc. Bio ceramics are the one of the most active areas of research. Bio ceramics are the ceramics which are biocompatible. The unique properties of bio ceramics make them an attractive option for medical applications and offer some potential advantages over other materials. During the past three decades, a number of major advances have been made in the field of bio ceramics. This review focuses on the use of these materials in variety of clinical scenarios.

  16. Autoimmune hepatitis: diagnostic criteria, subclassifications, and clinical features.

    Science.gov (United States)

    McFarlane, Ian G

    2002-08-01

    The diagnosis of AIH depends on the finding of several suggestive features together with careful exclusion of liver diseases of other etiologies. Wherever possible, the diagnosis should be confirmed histologically by an experienced hepatopathologist. Seronegativity for the conventional autoantibodies at presentation does not exclude a diagnosis of AIH. It is important to test for anti-LKM1 antibodies to avoid missing a diagnosis of type 2 AIH, with potentially serious consequences. Although the syndrome is associated with characteristic biochemical abnormalities, and biochemical parameters are commonly used for monitoring response to therapy, it should be borne in mind that neither these nor autoantibody titers are completely reliable indices of disease activity. Although the various systems that have been promulgated for classification of the disease may identify different groups of patients on pathogenetic or clinical criteria and are useful for research purposes, none is yet sufficiently exclusive in terms of defining prognosis or planning treatment strategies to be applicable to the individual patient seen in the clinic. Clinical management should therefore continue to be individually tailored.

  17. Insights into cerumen and application in diagnostics: past, present and future prospective.

    Science.gov (United States)

    Shokry, Engy; Filho, Nelson Roberto Antoniosi

    2017-10-15

    Cerumen or earwax is an emerging bio-fluid in clinical diagnosis that has been very little exploited during the past decades in spite of its high diagnostic potential. It is highly abundant in diagnostic biomarkers such as genetic material, lipids, proteins, chemical elements, internal and external metabolites ( e.g. hormones, volatile organic compounds, amino acids, xenobiotics etc. ) reaching earwax from the blood circulation. Thus, it is able to reflect not only physiology, pathophysiology of the human body but can also detect recent and long term exposure to environmental pollutants, without the need of invasive blood tests and in the same time overcoming many disadvantages faced by using other diagnostic biological fluids. This review discusses the biology, functions, chemistry of earwax, past and current approaches for the study of its chemical composition, emphasizing how a detected variation in its composition can offer information of high clinical value, which can be useful in diagnosis of many diseases such as metabolic disorders and tumours as well as in forensic applications. It also presents details about techniques of sample collection, storage, and analysis. Moreover, it highlights concerns about the use of earwax for diagnostic purposes, which should be addressed to make earwax diagnostics a reality in the future.

  18. PET/MRI. Methodology and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Carrio, Ignasi [Autonomous Univ. of Barcelona, Hospital Sant Pau (Spain). Dept. Medicina Nuclear; Ros, Pablo (ed.) [Univ. Hospitals Case, Medical Center, Cleveland, OH (United States). Dept. of Radiology

    2014-04-01

    Provides detailed information on the methodology and equipment of MRI-PET. Covers a wide range of clinical applications in oncology, cardiology, and neurology. Written by an international group of experts in MRI and PET. PET/MRI is an exciting novel diagnostic imaging modality that combines the precise anatomic and physiologic information provided by magnetic resonance imaging (MRI) with the molecular data obtained with positron emission tomography (PET). PET/MRI offers the promise of a simplified work flow, reduced radiation, whole-body imaging with superior soft tissue contrast, and time of flight physiologic information. It has been described as the pathway to molecular imaging in medicine. In compiling this textbook, the editors have brought together a truly international group of experts in MRI and PET. The book is divided into two parts. The first part covers methodology and equipment and comprises chapters on basic molecular medicine, development of specific contrast agents, MR attenuation and validation, quantitative MRI and PET motion correction, and technical implications for both MRI and PET. The second part of the book focuses on clinical applications in oncology, cardiology, and neurology. Imaging of major neoplasms, including lymphomas and tumors of the breast, prostate, and head and neck, is covered in individual chapters. Further chapters address functional and metabolic cardiovascular examinations and major central nervous system applications such as brain tumors and dementias. Risks, safety aspects, and healthcare costs and impacts are also discussed. This book will be of interest to all radiologists and nuclear medicine physicians who wish to learn more about the latest developments in this important emerging imaging modality and its applications.

  19. MO-C-BRB-06: Translating NIH / NIBIB funding to clinical reality in quantitative diagnostic imaging

    International Nuclear Information System (INIS)

    Jackson, E.

    2015-01-01

    Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration

  20. MO-C-BRB-06: Translating NIH / NIBIB funding to clinical reality in quantitative diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, E. [University of Wisconsin (United States)

    2015-06-15

    Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration

  1. Recent advances in control and diagnostics development and application

    International Nuclear Information System (INIS)

    Monson, L.R.; King, R.W.; Lindsay, R.W.; Staffon, J.D.

    1989-01-01

    The power industry is undergoing rapid technological advances and cultural changes. Technologies are advancing and evolving so rapidly that the industry is hard pressed to keep up and take full advantage of the many developments now in progress. Recent advantages in state-of-the-art computer technology are making in-roads in the form of advanced computer control, expert systems, on-line performance monitoring and diagnostics. Validation and verification schemes are being developed which provide increased confidence in the correctness and reliability of both computer hardware and software. Our challenge in the nuclear community is to effectively apply these new technologies to improve the operation, safety, and reliability of our plants. This presentation discusses two areas of development that are essential to advanced control strategies: application of diagnostic systems to improve fault-tolerance, and model-based graphic displays. 4 refs., 4 figs

  2. Coronary CT angiography: Diagnostic value and clinical challenges.

    Science.gov (United States)

    Sabarudin, Akmal; Sun, Zhonghua

    2013-12-26

    Coronary computed tomography (CT) angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography. Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320- slice CT scanners. Despite the promising diagnostic value, coronary CT angiography is still limited in some areas, such as inferior temporal resolution, motion-related artifacts and high false positive results due to severe calcification. The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners. Prognostic value of coronary CT angiography in coronary artery disease is also discussed, while limitations and challenges of coronary CT angiography are highlighted.

  3. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  4. Wilson's disease in children: clinical and diagnostic features

    International Nuclear Information System (INIS)

    Ayesha, H.; Choudhry, A.A.; Javed, M.T.; Javed, F.

    2002-01-01

    Objective: To study the clinical and diagnostic laboratory features of Wilsons disease in children and adolescents. Design: A prospective cohort study. Place and Duration of study: The study included patients diagnosed as Wilson s disease at the Department of Pediatrics Allied Hospital, Punjab medical College, Faisalabad from May 1997 to June 2001. Patients and methods: Patients presenting with liver or suggestive neurological disease were investigated. Others were diagnosed as a result of family screening. Diagnosis of neurologic disease was made if two of the following were present: Typical neurological findings, Kayser Fleischer corneal rings and low serum ceruloplasmin ( 100 mu gm) free serum copper (>10 mu gm/dl). In other forms and for family screening, 24 hours. Urinary copper (> 100 mu gm), free serum copper (>10 mu gm/dl), and wherever possible liver biopsy for histopathology and cytochemical staining by rubeanic acid was also done. Results: Twenty-seven patients with a mean age of 10.2 years were diagnosed as suffering from Wilson disease. Mean age for hepatic and neurological disease was 9 years and 11.5 years respectively. Youngest patient (neurologic) was 6 years old. 48% cases presented with neurological, 41% with hepatic and 4% with skeletal manifestations while 7 % were asymptomatic. Mean duration of symptoms before diagnosis was 6.1 months. Dysarthria (84.6%), tremors (69.2%), rigidity and poor school performance and hand writing (61.5%), dysphagia (46.1%) and dystonia (38.5%), were the most common neurologic findings. Chronic liver disease was seen in 73 % while acute forms were seen in 27 % cases. Two cases presented with fulminant hepatic failure. Consanguineous marriage of the parents was found in 70 % and family history of disease was present in 65 % cases. K-F (Kayser Fleischer) rings and low serum ceruloplasmin(<20 mg/dl) was found in 85% of all patients. In non neurologic types other tests of copper metabolism were done. Elevated urinary

  5. Clinical applications of iterative reconstruction

    International Nuclear Information System (INIS)

    Eberl, S.

    1998-01-01

    Expectation maximisation (EM) reconstruction largely eliminates the hot and cold streaking artifacts characteristic of filtered-back projection (FBP) reconstruction around localised hot areas, such as the bladder. It also substantially reduces the problem of decreased inferior wall counts in MIBI myocardial perfusion studies due to ''streaking'' from high liver uptake. Non-uniform attenuation and scatter correction, resolution recovery, anatomical information, e.g. from MRI or CT tracer kinetic modelling, can all be built into the EM reconstruction imaging model. The properties of ordered subset EM (OSEM) have also been used to correct for known patient motion as part of the reconstruction process. These uses of EM are elaborated more fully in some of the other abstracts of this meeting. Currently we use OSEM routinely for: (i) studies where streaking is a problem, including all MIBI myocardial perfusion studies, to avoid hot liver inferior wall artifact, (ii) all whole body FDG PET, all lung V/Q SPECT (which have a short acquisition time) and all gated 201 TI myocardial perfusion studies due to improved noise characteristics of OSEM in these studies; (iii) studies with measured, non-uniform attenuation correction. With the accelerated OSEM algorithm, iterative reconstruction is practical for routine clinical applications and we have found OSEM to provide clearly superior reconstructions for the areas listed above and are investigating its application to other studies. In clinical use, we have not found OSEM to introduce artifacts which would not also occur with FBP, e.g. uncorrected patient motion will cause artifacts with both OSEM and FBP

  6. Bayesian networks applied to process diagnostics. Applications in energy industry

    Energy Technology Data Exchange (ETDEWEB)

    Widarsson, Bjoern (ed.); Karlsson, Christer; Dahlquist, Erik [Maelardalen Univ., Vaesteraas (Sweden); Nielsen, Thomas D.; Jensen, Finn V. [Aalborg Univ. (Denmark)

    2004-10-01

    Uncertainty in process operation occurs frequently in heat and power industry. This makes it hard to find the occurrence of an abnormal process state from a number of process signals (measurements) or find the correct cause to an abnormality. Among several other methods, Bayesian Networks (BN) is a method to build a model which can handle uncertainty in both process signals and the process itself. The purpose of this project is to investigate the possibilities to use BN for fault detection and diagnostics in combined heat and power industries through execution of two different applications. Participants from Aalborg University represent the knowledge of BN and participants from Maelardalen University have the experience from modelling heat and power applications. The co-operation also includes two energy companies; Elsam A/S (Nordjyllandsverket) and Maelarenergi AB (Vaesteraas CHP-plant), where the two applications are made with support from the plant personnel. The project ended out in two quite different applications. At Nordjyllandsverket, an application based (due to the lack of process knowledge) on pure operation data is build with capability to detect an abnormal process state in a coal mill. Detection is made through a conflict analysis when entering process signals into a model built by analysing the operation database. The application at Maelarenergi is built with a combination of process knowledge and operation data and can detect various faults caused by the fuel. The process knowledge is used to build a causal network structure and the structure is then trained by data from the operation database. Both applications are made as off-online applications, but they are ready for being run on-line. The performance of fault detection and diagnostics are good, but a lack of abnormal process states with known cause reduces the evaluation possibilities. Advantages with combining expert knowledge of the process with operation data are the possibility to represent

  7. Applications of quantum cascade lasers in plasma diagnostics: a review

    International Nuclear Information System (INIS)

    Röpcke, J; Lang, N; Davies, P B; Rousseau, A; Welzel, S

    2012-01-01

    Over the past few years mid-infrared absorption spectroscopy based on quantum cascade lasers operating over the region from 3 to 12 µm and called quantum cascade laser absorption spectroscopy or QCLAS has progressed considerably as a powerful diagnostic technique for in situ studies of the fundamental physics and chemistry of molecular plasmas. The increasing interest in processing plasmas containing hydrocarbons, fluorocarbons, nitrogen oxides and organo-silicon compounds has led to further applications of QCLAS because most of these compounds and their decomposition products are infrared active. QCLAS provides a means of determining the absolute concentrations of the ground states of stable and transient molecular species at time resolutions below a microsecond, which is of particular importance for the investigation of reaction kinetics and dynamics. Information about gas temperature and population densities can also be derived from QCLAS measurements. Since plasmas with molecular feed gases are used in many applications such as thin film deposition, semiconductor processing, surface activation and cleaning, and materials and waste treatment, this has stimulated the adaptation of QCLAS techniques to industrial requirements including the development of new diagnostic equipment. The recent availability of external cavity (EC) QCLs offers a further new option for multi-component detection. The aim of this paper is fourfold: (i) to briefly review spectroscopic issues arising from applying pulsed QCLs, (ii) to report on recent achievements in our understanding of molecular phenomena in plasmas and at surfaces, (iii) to describe the current status of industrial process monitoring in the mid-infrared and (iv) to discuss the potential of advanced instrumentation based on EC-QCLs for plasma diagnostics. (topical review)

  8. Application of optical phase conjugation to plasma diagnostics (invited)

    International Nuclear Information System (INIS)

    Jahoda, F.C.; Anderson, B.T.; Forman, P.R.; Weber, P.G.

    1985-01-01

    Several possibilities for plasma diagnostics provided by optical phase conjugation and, in particular, self-pumped phase conjugation in barium titanate (BaTiO 3 ) are discussed. These include placing a plasma within a dye laser cavity equipped with a phase conjugate mirror for intracavity absorption measurements, time differential refractometry with high spatial resolution, and simplified real-time holographic interferometry. The principles of phase conjugation with particular reference to photorefractive media and the special advantages of self-pumped phase conjugation are reviewed prior to the discussion of the applications. Distinctions are made in the applications between those for which photorefractive conjugators are essential and those for which they only offer experimental simplification relative to other types of phase conjugators

  9. Nuclear power applications of NASA control and diagnostics technology

    International Nuclear Information System (INIS)

    Touchton, R.A.

    1990-05-01

    The main objective of Research Project RP2902-1, Nuclear Applications of NASA Control and Diagnostics Technology, were the assessment of NASA's KATE technology, development of a generic software tool suitable for use by the utility industry, and the building of a demonstration application in the power utility domain. Accordingly, the KATE technology was studied, evaluated and the essential features selected for reimplementation in a generic, user-friendly tool called ''ProSys.'' ProSys represents a growing interest in the use of computer systems to represent the causes for their undesired behavior. Recent attempts have concentrated on representing such knowledge and drawing inferences using a generic, model-based approach. Thus ProSys is a model-based diagnostic program that runs on a microcomputer. It is built on basic principles of troubleshooting, such as cause and effect, and not on experiential heuristics. Models built using ProSys store a knowledge of the structure and function of the system that is being diagnosed. ProSys uses this knowledge to draw inferences about the current state of the system. ProSys is also knowledgeable about the command inputs (operator actions) to the system and the effect that these have on the sensors. Thus, ProSys expects certain values from the sensors and when those are different, it works backwards to hypothesize the failure of system components. This document, Volume 2, provides a technical discussion of the system. 17 figs

  10. Applications of FASTBUS to beam diagnostics and experiment data systems

    International Nuclear Information System (INIS)

    Machen, D.R.

    1983-01-01

    A five-year effort by the North American NIM Committee, in collaboration with the ESONE Committee of European Laboratories, has resulted in a specification for the FASTBUS modular high-speed data-acquisition system. The system is designed around an emitter-coupled logic (ECL) 32-bit data bus for asynchronous data transmission at 100 ns per transaction. Initial applications of FASTBUS will be in experiment data systems at accelerator facilities worldwide--beam diagnostic data systems on the accelerator side and particle-beam experiment data systems in the experimental area. As the specification (and the resulting hardware and software) matures, real-time machine-control applications will become possible. This paper discusses the near-term use of FASTBUS in accelerator beam-diagnostics instrumentation systems, where an extra increment in system throughput and front-end processing speed can produce a greater understanding of the physical phenomena under study. The arguments and conclusions may be equally well applied to other similar data-handling problems requiring high bandwidth in the data system

  11. Two applications of direct digital down converters in beam diagnostics

    International Nuclear Information System (INIS)

    Powers, Tom; Flood, Roger; Hovater, Curt; Musson, John

    2000-01-01

    The technologies of direct digital down converters, digital frequency synthesis, and digital signal processing are being used in many commercial applications. Because of this commercialization, the component costs are being reduced to the point where they are economically viable for large scale accelerator applications. This paper will discuss two applications of these technologies to beam diagnostics. In the first application the combination of direct digital frequency synthesis and direct digital down converters are coupled with digital signal processor technology in order to maintain the stable gain environment required for a multi-electrode beam position monitoring system. This is done by injecting a CW reference signal into the electronics as part of the front-end circuitry. In the second application direct digital down converters are used to provide a novel approach to the measurement of beam intensity using cavity current monitors. In this system a pair of reference signals are injected into the cavity through an auxiliary port. The beam current is then calculated as the ratio of the beam signal divided by the average of the magnitude of the two reference signals

  12. Application of recombinant latex allergens in diagnostics of occupational latex allergy

    Directory of Open Access Journals (Sweden)

    Ewa Nowakowska-Świrta

    2015-02-01

    Full Text Available Over many years, allergy to natural rubber latex has been a major problem among health care workers (HCW. The diagnosis of occupational allergy requires methods of high diagnostic accuracy in view of certification implications (e.g., a sick worker quits a job. With the development of molecular methods, the frequency of application of recombinant allergens in the diagnostics of allergic diseases continues to increase. This paper reviews the applicability of laboratory tests which use recombinant allergens in the diagnostics of occupational allergy. The diagnosis of latex allergy is based on the presence of clinical symptoms linked with exposure to latex allergens, positive skin prick tests and detection of specific IgE antibodies to latex in serum. Moreover, in some cases specific challenge tests are conducted. The analysis of literature indicates that applying the panel of recombinant latex allergens in diagnostic tests, cross-reactivity can very likely be excluded and/or sensitization can be confirmed without the need for specific challenge tests, which in case of latex allergens carries a potential risk of generalized reactions. Med Pr 2015;66(1:85–97

  13. Next-Generation Sequencing in Clinical Molecular Diagnostics of Cancer: Advantages and Challenges

    Directory of Open Access Journals (Sweden)

    Rajyalakshmi Luthra

    2015-10-01

    Full Text Available The application of next-generation sequencing (NGS to characterize cancer genomes has resulted in the discovery of numerous genetic markers. Consequently, the number of markers that warrant routine screening in molecular diagnostic laboratories, often from limited tumor material, has increased. This increased demand has been difficult to manage by traditional low- and/or medium-throughput sequencing platforms. Massively parallel sequencing capabilities of NGS provide a much-needed alternative for mutation screening in multiple genes with a single low investment of DNA. However, implementation of NGS technologies, most of which are for research use only (RUO, in a diagnostic laboratory, needs extensive validation in order to establish Clinical Laboratory Improvement Amendments (CLIA and College of American Pathologists (CAP-compliant performance characteristics. Here, we have reviewed approaches for validation of NGS technology for routine screening of tumors. We discuss the criteria for selecting gene markers to include in the NGS panel and the deciding factors for selecting target capture approaches and sequencing platforms. We also discuss challenges in result reporting, storage and retrieval of the voluminous sequencing data and the future potential of clinical NGS.

  14. Temporomandibular disorders – validity of clinical diagnostics compared to magnetic resonance imaging

    OpenAIRE

    BADEL, TOMISLAV; MAROTTI, MILJENKO; SAVIĆ PAVIČIN, IVANA; DULČIĆ, NIKŠA; ZADRAVEC, DIJANA; KERN, JOSIPA

    2011-01-01

    Background and Purpose: Orthopedic examination techniques of the musculoskeletal system contribute to the successful diagnostics of temporomandibular disorders (TMD). The purpose of this study is to determine the validity of TMD clinical diagnostics by comparing the findings of manual functional analysis (MFA) and the results of MRI of temporomandibular joint (TMJ). The diagnostic significance of limited mouth opening and pain upon passive mouth opening were taken into consideration. M...

  15. Retrieval of diagnostic and treatment studies for clinical use through PubMed and PubMed's Clinical Queries filters.

    Science.gov (United States)

    Lokker, Cynthia; Haynes, R Brian; Wilczynski, Nancy L; McKibbon, K Ann; Walter, Stephen D

    2011-01-01

    Clinical Queries filters were developed to improve the retrieval of high-quality studies in searches on clinical matters. The study objective was to determine the yield of relevant citations and physician satisfaction while searching for diagnostic and treatment studies using the Clinical Queries page of PubMed compared with searching PubMed without these filters. Forty practicing physicians, presented with standardized treatment and diagnosis questions and one question of their choosing, entered search terms which were processed in a random, blinded fashion through PubMed alone and PubMed Clinical Queries. Participants rated search retrievals for applicability to the question at hand and satisfaction. For treatment, the primary outcome of retrieval of relevant articles was not significantly different between the groups, but a higher proportion of articles from the Clinical Queries searches met methodologic criteria (p=0.049), and more articles were published in core internal medicine journals (p=0.056). For diagnosis, the filtered results returned more relevant articles (p=0.031) and fewer irrelevant articles (overall retrieval less, p=0.023); participants needed to screen fewer articles before arriving at the first relevant citation (p<0.05). Relevance was also influenced by content terms used by participants in searching. Participants varied greatly in their search performance. Clinical Queries filtered searches returned more high-quality studies, though the retrieval of relevant articles was only statistically different between the groups for diagnosis questions. Retrieving clinically important research studies from Medline is a challenging task for physicians. Methodological search filters can improve search retrieval.

  16. Clinical application of cardiac SPECT

    International Nuclear Information System (INIS)

    Nishimura, Shigeyuki

    1999-01-01

    Single-photon emission computed tomography (SPECT) has replaced planar imaging techniques for myocardial scintigraphy. Thallium-201 was the dominant agent employed for myocardial perfusion imaging. Today new technetium-99m labelled radionuclides have been used as excellent alternatives to 201 Tl for detection of coronary artery disease, prognostification, and even assessment of myocardial viability. Pharmacologic stress imaging using either dipyridamole, adenosine or dobutamine is a substitute for exercise stress. Accurate determination of myocardial viability is vitally important for clinical decision making for patients with LV dysfunction who will most benefit from revascularization. Stunned and hibernated myocardium may result in profound regional LTV dysfunction in absence of necrosis. The various approach such as stress-redistribution-reinjection imaging, rest-redistribution imaging and stress-redistribution-24 hours delayed imaging has been utilized to assess myocardial viability with 201 Tl. Quantitative assessment of 99m Tc MIBI uptake reflect the degree of viability. 123 I-Metaiodobenzylguanidine (MIBG), an analog of norepinephrine, has been used for scintigraphic assessment of regional cardiac adrenergic innervation. Cardiac sympathetic denervation, assessed by 123 I-MIBG, due to ischemia in non-Q myocardial infarction and unstable angina has been shown. Quantitative cardiac MIBG scintigram was shown to have prognostic value in patients with severe congestive heart failure. 23 I-BMIPP (ρ-methyl-iodophenyl pentadecanoic acid) has been used to assess myocardial fatty acid utilization. BMIPP has the memory function of ischemia in unstable angina, since decreased BMIPP uptake persists several days after ischemic episode. Nuclear cardiology in Japan has experienced an expansion in the techniques including use of new radionuclides, 99m Tc perfusion agents, 123 I-MIBG and 23 I-BMIPP and in associated clinical application to the various cardiac diseases

  17. A new generation of optical diagnostics for bladder cancer: technology, diagnostic accuracy, and future applications

    NARCIS (Netherlands)

    Cauberg, Evelyne C. C.; de Bruin, Daniël M.; Faber, Dirk J.; van Leeuwen, Ton G.; de La Rosette, Jean J. M. C. H.; de Reijke, Theo M.

    2009-01-01

    CONTEXT: New developments in optical diagnostics have a potential for less invasive and improved detection of bladder cancer. OBJECTIVE: To provide an overview of the technology and diagnostic yield of recently developed optical diagnostics for bladder cancer and to outline their potential future

  18. Protease activity measurement in milk as a diagnostic test for clinical mastitis in dairy cows

    NARCIS (Netherlands)

    Koop, G.; van Werven, T.; Roffel, S.; Hogeveen, H.; Nazmi, K.; Bikker, F.J.

    2015-01-01

    Due to the increasing use of automated milking systems, automated detection of clinical mastitis is becoming more important. Various in- or on-line diagnostic tests are in use, but generally suffer from false mastitis alerts. In this study, we explored a new diagnostic approach based on measurement

  19. Companion diagnostics and molecular imaging-enhanced approaches for oncology clinical trials.

    Science.gov (United States)

    Van Heertum, Ronald L; Scarimbolo, Robert; Ford, Robert; Berdougo, Eli; O'Neal, Michael

    2015-01-01

    In the era of personalized medicine, diagnostic approaches are helping pharmaceutical and biotechnology sponsors streamline the clinical trial process. Molecular assays and diagnostic imaging are routinely being used to stratify patients for treatment, monitor disease, and provide reliable early clinical phase assessments. The importance of diagnostic approaches in drug development is highlighted by the rapidly expanding global cancer diagnostics market and the emergent attention of regulatory agencies worldwide, who are beginning to offer more structured platforms and guidance for this area. In this paper, we highlight the key benefits of using companion diagnostics and diagnostic imaging with a focus on oncology clinical trials. Nuclear imaging using widely available radiopharmaceuticals in conjunction with molecular imaging of oncology targets has opened the door to more accurate disease assessment and the modernization of standard criteria for the evaluation, staging, and treatment responses of cancer patients. Furthermore, the introduction and validation of quantitative molecular imaging continues to drive and optimize the field of oncology diagnostics. Given their pivotal role in disease assessment and treatment, the validation and commercialization of diagnostic tools will continue to advance oncology clinical trials, support new oncology drugs, and promote better patient outcomes.

  20. A Practical Approach to Tumor Heterogeneity in Clinical Research and Diagnostics.

    Science.gov (United States)

    Stanta, Giorgio; Bonin, Serena

    2018-01-01

    This Pathobiology issue tries to better define the complex phenomenon of intratumor heterogeneity (ITH), mostly from a practical point of view. This topic has been chosen because ITH is a central issue in tumor development and has to be investigated directly in patient tissue and immediately applied in the treatment of the presenting patient. Different types of ITH should be considered: clonal genetic and epigenetic evolution, morphological heterogeneity, and tumor sampling, heterogeneity resulting from microenvironmental autocrine and paracrine interaction, and stochastic plasticity related to different functional cell efficiencies. For a higher level of reproducibility in clinical research and diagnostics, it is necessary to establish standardized analytical methods, including microdissection. In situ techniques can be pivotal to explore tumor microenvironment and can be improved with associated digital analysis. Liquid biopsies for plasma DNA analysis are at present the best method to study recurrent tumors with treatment adaptation, and widespread clinical use could be beneficial. The different types of tumor genomic instabilities could have pragmatic applications to rank ITH for clinical applications: treatment approaches differ in patients with a high nucleotide mutation rate and patients with high copy number alterations. © 2017 S. Karger AG, Basel.

  1. Clinical review: Distinguishing constitutional delay of growth and puberty from isolated hypogonadotropic hypogonadism: critical appraisal of available diagnostic tests.

    Science.gov (United States)

    Harrington, Jennifer; Palmert, Mark R

    2012-09-01

    Determining the etiology of delayed puberty during initial evaluation can be challenging. Specifically, clinicians often cannot distinguish constitutional delay of growth and puberty (CDGP) from isolated hypogonadotropic hypogonadism (IHH), with definitive diagnosis of IHH awaiting lack of spontaneous puberty by age 18 yr. However, the ability to make a timely, correct diagnosis has important clinical implications. The aim was to describe and evaluate the literature regarding the ability of diagnostic tests to distinguish CDGP from IHH. A PubMed search was performed using key words "puberty, delayed" and "hypogonadotropic hypogonadism," and citations within retrieved articles were reviewed to identify studies that assessed the utility of basal and stimulation tests in the diagnosis of delayed puberty. Emphasis was given to a test's ability to distinguish prepubertal adolescents with CDGP from those with IHH. Basal gonadotropin and GnRH stimulation tests have limited diagnostic specificity, with overlap in gonadotropin levels between adolescents with CDGP and IHH. Stimulation tests using more potent GnRH agonists and/or human chorionic gonadotropin may have better discriminatory value, but small study size, lack of replication of diagnostic thresholds, and prolonged protocols limit clinical application. A single inhibin B level in two recent studies demonstrated good differentiation between groups. Distinguishing IHH from CDGP is an important clinical issue. Basal inhibin B may offer a simple, discriminatory test if results from recent studies are replicated. However, current literature does not allow for recommendation of any diagnostic test for routine clinical use, making this an important area for future investigation.

  2. Application of aluminum phthalocyanine nanoparticles for fluorescent diagnostics in dentistry and skin autotransplantology.

    Science.gov (United States)

    Vasilchenko, Sergey Yu; Volkova, Anna I; Ryabova, Anastasiya V; Loschenov, Victor B; Konov, Vitaly I; Mamedov, Adil A; Kuzmin, Sergey G; Lukyanets, Evgeniy A

    2010-06-01

    This paper deals with the possibility of application of aluminum phthalocyanine (AlPc) nanoparticles in clinical practice. AlPc fluoresces in the molecular form but in the form of nanoparticles it does not. Separation of molecules from an AlPc nanoparticle and therefore the appearance of fluorescence occurs under the effect of a number of biochemo-physical factors. Owing to this feature the application of AlPc nanoparticles followed by the measurement of fluorescence spectra is proposed as a diagnostics method. It was shown that after AlPc nanoparticle application on a tooth surface the fluorescence intensity in the enamel microdamage area is 2-3 times higher than that in the normal enamel area. The appearance of fluorescence after application of AlPc nanoparticles on skin autografts testifies to the presence of inflammation. (c) 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. The Added Value of the Combined Use of the Autism Diagnostic Interview-Revised and the Autism Diagnostic Observation Schedule: Diagnostic Validity in a Clinical Swedish Sample of Toddlers and Young Preschoolers

    Science.gov (United States)

    Zander, Eric; Sturm, Harald; Bölte, Sven

    2015-01-01

    The diagnostic validity of the new research algorithms of the Autism Diagnostic Interview-Revised and the revised algorithms of the Autism Diagnostic Observation Schedule was examined in a clinical sample of children aged 18-47 months. Validity was determined for each instrument separately and their combination against a clinical consensus…

  4. Application of diagnostic reference levels in medical practice

    Energy Technology Data Exchange (ETDEWEB)

    Bourguignon, Michel [Faculty of Medicine of Paris, Deputy Director General, Nuclear Safety Authority (ASN), Paris (France)

    2006-07-01

    Diagnosis reference levels (D.R.L.) are defined in the Council Directive 97/43 EURATOM as 'Dose levels in medical radio diagnosis practices or in the case of radiopharmaceuticals, levels of activity, for typical examinations for groups of standards-sized patients or standards phantoms for broadly defined types of equipment. These levels are expected not to be exceeded for standard procedures when good and normal practice regarding diagnostic and technical performance is applied'. Thus D.R.L. apply only to diagnostic procedures and does not apply to radiotherapy. Radiation protection of patients is based on the application of 2 major radiation protection principles, justification and optimization. The justification principle must be respected first because the best way to protect the patient is not to carry a useless test. Radiation protection of the patient is a continuous process and local dose indicator values in the good range should not prevent the radiologist or nuclear medicine physician to continue to optimize their practice. (N.C.)

  5. Application of diagnostic reference levels in medical practice

    International Nuclear Information System (INIS)

    Bourguignon, Michel

    2006-01-01

    Diagnosis reference levels (D.R.L.) are defined in the Council Directive 97/43 EURATOM as 'Dose levels in medical radio diagnosis practices or in the case of radiopharmaceuticals, levels of activity, for typical examinations for groups of standards-sized patients or standards phantoms for broadly defined types of equipment. These levels are expected not to be exceeded for standard procedures when good and normal practice regarding diagnostic and technical performance is applied'. Thus D.R.L. apply only to diagnostic procedures and does not apply to radiotherapy. Radiation protection of patients is based on the application of 2 major radiation protection principles, justification and optimization. The justification principle must be respected first because the best way to protect the patient is not to carry a useless test. Radiation protection of the patient is a continuous process and local dose indicator values in the good range should not prevent the radiologist or nuclear medicine physician to continue to optimize their practice. (N.C.)

  6. A Decade of Development of Chromogenic Culture Media for Clinical Microbiology in an Era of Molecular Diagnostics.

    Science.gov (United States)

    Perry, John D

    2017-04-01

    In the last 25 years, chromogenic culture media have found widespread application in diagnostic clinical microbiology. In the last decade, the range of media available to clinical laboratories has expanded greatly, allowing specific detection of additional pathogens, including Pseudomonas aeruginosa, group B streptococci, Clostridium difficile, Campylobacter spp., and Yersinia enterocolitica. New media have also been developed to screen for pathogens with acquired antimicrobial resistance, including vancomycin-resistant enterococci, carbapenem-resistant Acinetobacter spp., and Enterobacteriaceae with extended-spectrum β-lactamases and carbapenemases. This review seeks to explore the utility of chromogenic media in clinical microbiology, with particular attention given to media that have been commercialized in the last decade. The impact of laboratory automation and complementary technologies such as matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is also assessed. Finally, the review also seeks to demarcate the role of chromogenic media in an era of molecular diagnostics. © Crown copyright 2017.

  7. [THE VIRTUAL CYTOLOGIC SLIDES FOR EXTERNAL EVALUATION OF QUALITY OF IMPLEMENTATION OF CYTOLOGIC ANALYSES IN CLINICAL DIAGNOSTIC LABORATORIES: POSSIBILITIES AND PERSPECTIVES].

    Science.gov (United States)

    Djangirova, T V; Shabalova, I P; Pronichev, A N; Polyakov, E V

    2015-08-01

    The article considers application of technology of analysis of cytological slides in external quality control of clinical diagnostic laboratories. The advantages of virtual slides are demonstrated against other applied technologies of external evaluation of quality i.e. slide plate and digital micro-photography. The conditions of formation of virtual slides for external evaluation of quality of clinical diagnostic laboratories. The technology of their application is described. The success of practical application of considered technology in the Federal system of external evaluation of quality is emphasized.

  8. Optically pumped FIR lasers and their application in plasma diagnostics

    International Nuclear Information System (INIS)

    Bakos, J.S.

    1986-06-01

    The pysics and the construction of the far infrared lasers (FIRL) and of the infrared lasers pumping them are reviewed. The details of the construction, resonating and pumping systems, spectral and power characteristics of the FIRLs are discussed. Recently more than 1000 laser lines are known and used in the 27-80 mm wavelength range, but in many cases the laser kinetics are not fully understood, and some instability phenomena cannot be prevented. New nonlinear processes were found: two-photon pumping, hyper Raman laser tuning and relaxation phenomena. A broad application field, the plasma diagnostics by far infrared lasers is described. Scattering of infrared laser radiation can give new interesting information on the not understood effect of the anomalous transport in the high temperature plasma. (D.Gy.)

  9. Examples for application and diagnostics in plasma-powder interaction

    International Nuclear Information System (INIS)

    Kersten, H; Wiese, R; Thieme, G; Froehlich, M; Kopitov, A; Bojic, D; Scholze, F; Neumann, H; Quaas, M; Wulff, H; Hippler, R

    2003-01-01

    Low-pressure plasmas offer a unique possibility of confinement, control and fine tailoring of particle properties. Hence, dusty plasmas have grown into a vast field and new applications of plasma-processed dust particles are emerging. There is demand for particles with special properties and for particle-seeded composite materials. For example, the stability of luminophore particles could be improved by coating with protective Al 2 O 3 films which are deposited by a PECVD process using a metal-organic precursor gas. Alternatively, the interaction between plasma and injected micro-disperse powder particles can also be used as a diagnostic tool for the study of plasma surface processes. Two examples will be provided: the interaction of micro-sized (SiO 2 ) grains confined in a radiofrequency plasma with an external ion beam as well as the effect of a dc-magnetron discharge on confined particles during deposition have been investigated

  10. Recent applications of nuclear medicine in diagnostics (I part

    Directory of Open Access Journals (Sweden)

    Giorgio Treglia

    2013-04-01

    Full Text Available Introduction: Aim of this review is to describe the recent applications of nuclear medicine techniques in diagnostics, particularly in oncology. Materials and methods: We reviewed scientific literature data searching for the current role of tomographic nuclear medicine techniques (SPECTand PET in oncology and summarized the main applications of these techniques. Results: Nuclear medicine techniques have a key role in oncology allowing early diagnosis of many tumours, an accurate staging of disease and evalutation of treatment response. Hybrid SPECT/CT and PET/CT imaging systems now provide metabolic and functional information from SPECTor PETcombined with the high spatial resolution and anatomic information of CT. The most frequent applications of SPECT/CT in oncology concern thyroid tumours, neuroendocrine tumours, bone metastases and lymph node mapping. Furthermore the evaluation of many tumours may benefit from PET/CT imaging. Discussion: The recent development of new radiopharmaceuticals and the growth of hybrid tomographic devices, such as SPECT/CT and PET/CT, now permits molecular imaging of biologic processes at the cellular level to improve both the diagnosis and treatment of many tumours.

  11. [THE RESULTS OF CLINICAL AND PSYCHOPATHOLOGICAL AND PSYCHOLOGICAL DIAGNOSTIC INVESTIGATIONS EMPLOYEES OF FINANCIAL INSTITUTIONS WHICH WERE IDENTIFIED NEUROTIC DISORDERS].

    Science.gov (United States)

    Solovyova, M

    2014-12-01

    The article presents the results of the clinical and psychopathological and psychological diagnostic, investigations mental health employees of financial institutions, description and analysis of clinical forms identified disorders.

  12. Clinical application of functional MRI

    International Nuclear Information System (INIS)

    Taniwaki, Takayuki

    2010-01-01

    Described is the present state of clinical application of fMRI in the preoperative assessment of brain tumors, and plasticity in and pathophysiology of central diseases. For the tumor resection, fMRI is useful for risk assessment of postoperative nerve dysfunction, for selection of the patient rather suitable for brain mapping at the invasive surgery than at the pre-operation and for guidance of the operation itself. Preoperative fMRI alone can neither distinguish the regions of the primary and secondary functions nor exhibit the relation between the tumor and white matter fibers but there are compensatory means for these drawbacks. Benefit of preoperative fMRI has not yet been based on the evidence on double blind trials. Combination of fMRI imaging and electroencephalography (EEG) finding has shown that, in generalized epilepsy, extensive and stimulated activation occurs in both frontal/occipital regions and in thalamus area, respectively, and that the concomitant lowered activities are conceivably the reflection of burst discharge in normal brain functions. Plasticity in the human brain has been demonstrated by fMRI in cerebral vascular diseases, multiple sclerosis and amyotrophic lateral sclerosis. Pathogenesis of Parkinson disease and depression has been better understood by fMRI investigations revealing regions with elevated and reduced activities. Studies of attention deficit hyperactivity disorder have shown similar change of activities with functional reductions of the right dorsolateral frontal anterior area and of dorsal frontal cingulate gyrus, together with stimulated wider regions to given tasks. As above, fMRI has greatly contributed to our understanding of diseases of central nervous system and is to be expected to expand wider in this field. (T.T.)

  13. Facial diplegia: etiology, clinical manifestations, and diagnostic evaluation

    Directory of Open Access Journals (Sweden)

    Sefer Varol

    2015-12-01

    Full Text Available ABSTRACT Objective Facial diplegia (FD is a rare neurological manifestation with diverse causes. This article aims to systematically evaluate the etiology, diagnostic evaluation and treatment of FD. Method The study was performed retrospectively and included 17 patients with a diagnosis of FD. Results Patients were diagnosed with Guillain-Barré syndrome (GBS (11, Bickerstaff’s brainstem encephalitis (1, neurosarcoidosis (1, non-Hodgkin’s Lymphoma (1, tuberculous meningitis (1 herpes simplex reactivation (1 and idiopathic (1. In addition, two patients had developed FD during pregnancy. Conclusion Facial diplegia is an ominous symptom with widely varying causes that requires careful investigation.

  14. Evaluating next-generation sequencing for direct clinical diagnostics in diarrhoeal disease

    DEFF Research Database (Denmark)

    Joensen, Katrine Grimstrup; Engsbro, A L Ø; Lukjancenko, Oksana

    2017-01-01

    The accurate microbiological diagnosis of diarrhoea involves numerous laboratory tests and, often, the pathogen is not identified in time to guide clinical management. With next-generation sequencing (NGS) becoming cheaper, it has huge potential in routine diagnostics. The aim of this study...... was to evaluate the potential of NGS-based diagnostics through direct sequencing of faecal samples. Fifty-eight clinical faecal samples were obtained from patients with diarrhoea as part of the routine diagnostics at Hvidovre University Hospital, Denmark. Ten samples from healthy individuals were also included...

  15. Diagnostic accuracy of clinical breast examination for breast cancer ...

    African Journals Online (AJOL)

    All the consecutive patients with palpable breast lesions presenting at the general surgery out-patient clinics were recruited and evaluated clinically. Biopsy was performed on all the patients (open or core needle) and histology reports obtained. Data collected were recorded in a proforma and subsequently analyzed.

  16. Diagnostic accuracy of coronary CT angiography using 3{sup rd}-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Caruso, Damiano [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Tesche, Christian [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Heart Centre Munich-Bogenhausen, Department of Cardiology, Munich (Germany); Steinberg, Daniel H.; Bayer, Richard R. [Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Varga-Szemes, Akos; Stubenrauch, Andrew C.; Biancalana, Matthew; De Cecco, Carlo N. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-06-15

    To investigate diagnostic accuracy of 3{sup rd}-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m{sup 2}, n = 37) and B (≥30 kg/m{sup 2}, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CCTA using 3{sup rd}-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. (orig.)

  17. Diagnostic accuracy of coronary CT angiography using 3"r"d-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population

    International Nuclear Information System (INIS)

    Mangold, Stefanie; Wichmann, Julian L.; Schoepf, U.J.; Caruso, Damiano; Tesche, Christian; Steinberg, Daniel H.; Bayer, Richard R.; Varga-Szemes, Akos; Stubenrauch, Andrew C.; Biancalana, Matthew; De Cecco, Carlo N.; Nikolaou, Konstantin

    2017-01-01

    To investigate diagnostic accuracy of 3"r"d-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m"2, n = 37) and B (≥30 kg/m"2, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CCTA using 3"r"d-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. (orig.)

  18. The clinical application of fMRI data in a single-patient diagnostic conundrum: Classifying brain response to experimental pain to distinguish between gastrointestinal, depressive and eating disorder symptoms.

    Science.gov (United States)

    Strigo, Irina A; Murray, Stuart B; Simmons, Alan N; Bernard, Rebecca S; Huang, Jeannie S; Kaye, Walter H

    2017-11-01

    Patients with eating disorders (EDs) often present with psychiatric comorbidity, and functional and/or organic gastrointestinal (GI) symptomatology. Such multidiagnostic presentations can complicate diagnostic practice and treatment delivery. Here we describe an adolescent patient who presented with mixed ED, depressive, and GI symptomatology, who had received multiple contrasting diagnoses throughout treatment. We used a novel machine learning approach to classify (i) the patient's functional brain imaging during an experimental pain paradigm, and (ii) patient self-report psychological measures, to categorize the diagnostic phenotype most closely approximated by the patient. Specifically, we found that the patient's response to pain anticipation and experience within the insula and anterior cingulate cortices, and patient self-report data, were most consistent with patients with GI pain. This work is the first to demonstrate the possibility of using imaging data, alongside supervised learning models, for purposes of single patient classification in those with ED symptomatology, where diagnostic comorbidity is common. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Diagnostic issues, clinical characteristics, and outcomes for patients with fungemia

    DEFF Research Database (Denmark)

    Arendrup, Maiken Cavling; Sulim, Sofia; Holm, Anette

    2011-01-01

    This study investigated microbiological, clinical, and management issues and outcomes for Danish fungemia patients. Isolates and clinical information were collected at six centers. A total of 334 isolates, 316 episodes, and 305 patients were included, corresponding to 2/3 of the national episodes...... needed longer incubation. Species distribution varied by age, prior antifungal treatment (57% occurrence of C. glabrata, Saccharomyces cerevisiae, or C. krusei in patients with prior antifungal treatment versus 28% occurrence in those without it; P = 0.007), and clinical specialty (61% occurrence of C...

  20. Diagnostic Issues, Clinical Characteristics, and Outcomes for Patients with Fungemia

    DEFF Research Database (Denmark)

    Arendrup, Maiken Cavling; Sulim, Sofia; Holm, Anette

    2011-01-01

    This study investigated microbiological, clinical, and management issues and outcomes for Danish fungemia patients. Isolates and clinical information were collected at six centers. A total of 334 isolates, 316 episodes, and 305 patients were included, corresponding to 2/3 of the national episodes...... needed longer incubation. Species distribution varied by age, prior antifungal treatment (57% occurrence of C. glabrata, Saccharomyces cerevisiae, or C. krusei in patients with prior antifungal treatment versus 28% occurrence in those without it; P = 0.007), and clinical specialty (61% occurrence of C...

  1. What is the role of clinical tests and ultrasound in acetabular labral tear diagnostics?

    DEFF Research Database (Denmark)

    Troelsen, Anders; Mechlenburg, Inger; Gelineck, John

    2009-01-01

    BACKGROUND AND PURPOSE: An acetabular labral tear is a diagnostic challenge. Various clinical tests have been described, but little is known about their diagnostic sensitivity and specificity. We investigated the diagnostic validity of clinical tests and ultrasound as compared with MR arthrography...... no or only slight signs of osteoarthritis (Tönnis grade 0-1). RESULTS: MR arthrography identified labral tears in 17 of the 18 hips. Ultrasound had a sensitivity of 94%, a positive predictive value of 94%, and was false negative in only 1 case compared to MR arthrography. The impingement test had the best...... diagnostic ability of the clinical tests, with a sensitivity of 59% and a specificity of 100%. The positive predictive value was 100% while the negative predictive value was 13%. INTERPRETATION: The impingement test is helpful in identifying acetabular labral tears. If this test is negative and if a labral...

  2. Diagnostic Consideration for Sinonasal Wegener's Granulomatosis Clinically Mistaken for Carcinoma

    Science.gov (United States)

    La Rosa, Cristina; Emmanuele, Carmela; Tranchina, Maria Grazia; Ippolito, Massimo; Cosentino, Sebastiano; Saita, Vincenzo; Fraggetta, Filippo

    2013-01-01

    We report a case of Wegener's granulomatosis clinically mistaken for carcinoma in a 21-year-old girl presenting with an ulcerated mass of the nasopharynx associated with enlarged laterocervical nodes. The lesion was clinically suspected as malignant on the basis of clinical and radiological findings (namely, computed tomography scan and positron emission tomography). However, multiple biopsies were not conclusive for malignancy showing histological change suggestive of Wegener's granulomatosis. A serum determination of cANCA supported the diagnosis of Wegener's granulomatosis. Clinical findings and image studies suggested an erroneous diagnosis of malignancy whereas a definitive diagnosis of Wegener's granulomatosis was achieved only after repeated biopsies thus leading to a correct therapeutic approach. The Wegener granulomatosis must be added to the list of the differential diagnoses of the masses of the nasopharynx associated with or without enlarged laterocervical nodes. PMID:24106630

  3. Is the diagnostic threshold for bulimia nervosa clinically meaningful?

    Science.gov (United States)

    Chapa, Danielle A N; Bohrer, Brittany K; Forbush, Kelsie T

    2018-01-01

    The DSM-5 differentiates full- and sub-threshold bulimia nervosa (BN) according to average weekly frequencies of binge eating and inappropriate compensatory behaviors. This study was the first to evaluate the modified frequency criterion for BN published in the DSM-5. The purpose of this study was to test whether community-recruited adults (N=125; 83.2% women) with current full-threshold (n=77) or sub-threshold BN (n=48) differed in comorbid psychopathology and eating disorder (ED) illness duration, symptom severity, and clinical impairment. Participants completed the Clinical Impairment Assessment and participated in semi-structured clinical interviews of ED- and non-ED psychopathology. Differences between the sub- and full-threshold BN groups were assessed using MANOVA and Chi-square analyses. ED illness duration, age-of-onset, body mass index (BMI), alcohol and drug misuse, and the presence of current and lifetime mood or anxiety disorders did not differ between participants with sub- and full-threshold BN. Participants with full-threshold BN had higher levels of clinical impairment and weight concern than those with sub-threshold BN. However, minimal clinically important difference analyses suggested that statistically significant differences between participants with sub- and full-threshold BN on clinical impairment and weight concern were not clinically significant. In conclusion, sub-threshold BN did not differ from full-threshold BN in clinically meaningful ways. Future studies are needed to identify an improved frequency criterion for BN that better distinguishes individuals in ways that will more validly inform prognosis and effective treatment planning for BN. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Clinical Evaluation of Rapid Diagnostic Test Kit for Scrub Typhus with Improved Performance.

    Science.gov (United States)

    Kim, Young-Jin; Park, Sungman; Premaratna, Ranjan; Selvaraj, Stephen; Park, Sang-Jin; Kim, Sora; Kim, Donghwan; Kim, Min Soo; Shin, Dong Hoon; Choi, Kyung-Chan; Kwon, Soon-Hwan; Seo, Wonjun; Lee, Nam Taek; Kim, Seung-Han; Kang, Heui Keun; Kim, Yoon-Won

    2016-08-01

    Diagnosis of scrub typhus is challenging due to its more than twenty serotypes and the similar clinical symptoms with other acute febrile illnesses including leptospirosis, murine typhus and hemorrhagic fever with renal syndrome. Accuracy and rapidity of a diagnostic test to Orientia tsutsugamushi is an important step to diagnose this disease. To discriminate scrub typhus from other diseases, the improved ImmuneMed Scrub Typhus Rapid Diagnostic Test (RDT) was evaluated in Korea and Sri Lanka. The sensitivity at the base of each IgM and IgG indirect immunofluorescent assay (IFA) in Korean patients was 98.6% and 97.1%, and the specificity was 98.2% and 97.7% respectively. The sensitivity and specificity for retrospective diagnosis at the base of IFA in Sri Lanka was 92.1% and 96.1%. ImmuneMed RDT was not reactive to any serum from seventeen diseases including hemorrhagic fever with renal syndrome (n = 48), leptospirosis (n = 23), and murine typhus (n = 48). ImmuneMed RDT shows superior sensitivity (98.6% and 97.1%) compared with SD Bioline RDT (84.4% at IgM and 83.3% at IgG) in Korea. The retrospective diagnosis of ImmuneMed RDT exhibits 94.0% identity with enzyme-linked Immunosorbent assay (ELISA) using South India patient serum samples. These results suggest that this RDT can replace other diagnostic tests and is applicable for global diagnosis of scrub typhus. This rapid and accurate diagnosis will be beneficial for diagnosing and managing scrub typhus.

  5. Cultivating Humility and Diagnostic Openness in Clinical Judgment.

    Science.gov (United States)

    Stone, John R

    2017-10-01

    In this case, a physician rejects a patient's concerns that tainted water is harming the patient and her community. Stereotypes and biases regarding socioeconomic class and race/ethnicity, constraining diagnostic frameworks, and fixed first impressions could skew the physician's judgment. This paper narratively illustrates how cultivating humility could help the physician truly hear the patient's suggestions. The discussion builds on the multifaceted concept of cultural humility as a lifelong journey that addresses not only stereotypes and biases but also power inequalities and community inequities. Insurgent multiculturalism is a complementary concept. Through epistemic humility-which includes both intellectual and emotional components-and admitting uncertainty, physicians can enhance patients' and families' epistemic authority and health agency. © 2017 American Medical Association. All Rights Reserved.

  6. Deafness genes in Israel: implications for diagnostics in the clinic.

    Science.gov (United States)

    Brownstein, Zippora; Avraham, Karen B

    2009-08-01

    The identification of the molecular basis of deafness in the last decade has made a remarkable impact on genetic counseling and diagnostics for the hearing impaired population. Since the discovery of the most prevalent form of deafness associated with mutations in the GJB2 (connexin 26) gene, many other genes have been found worldwide, with a subset of these, including unique mutations, in Israel. Here, we review the current status of deafness genes in Israel and report one known mutation in a syndromic form of deafness, Usher syndrome, described in the Jewish Israeli population for the first time. In the future, the identification of specific mutations may be relevant for specific types of treatment.

  7. Application of noise analysis methods in nuclear reactor diagnostics

    International Nuclear Information System (INIS)

    Dach, K.

    1985-01-01

    By statistical evaluation of the fluctuation component of signals from selected detectors, noise diagnostics detects conditions of equipment which might later result in failure. The objective of early diagnostics is to detect the failed integrity of primary circuit components, failed detectors or anomalies of the thermohydraulic process. The commonest method of experimental data analysis is spectral analysis in the frequency range 0 to 50 Hz. Recently, expert diagnostic systems have been built based on artificial intelligence systems. Czechoslovakia participates in the experimental research of noise diagnostics in the context of the development of diagnostic assemblies for WWER-440 reactors. (M.D.)

  8. Application of contemporary imaging methods in diagnostics of mild cognitive impairment

    International Nuclear Information System (INIS)

    Walecki, J.; Pawlowska-Detko, A.; Ignaciuk, K.; Gabryelewicz, T.; Barcikowska, M.

    2006-01-01

    Mild cognitive impairment (MCI) is defined as a heterogeneous clinical syndrome associated with high risk of the development of dementia, especially Alzheimer disease (AD). Owing to the recent advances in understanding of the molecular phenomena underlying AD there is a chance of introducing effective therapy for this disease in the near future. Therefore, improvement of early diagnostics methods and finding the markers of AD progression, especially in the high risk population of patients with MCI becomes a crucial issue. From the clinical point of view, great expectations are associated with neuroradiologic methods, which are hoped to make it possible to find the markers of conversion from MCI to dementia and the markers of dementia progression in subjects at risk of the development of AD. Growing interest in the problem of MCI diagnostics, reflected in numerous medical publications that have appeared during the recent few years, has prompted the authors to review and summarize the current knowledge concerning the application of modern neuroradiologic methods in the diagnostics of subjects with MCI. (author)

  9. Clinical application of digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Hiroyuki; Nagasaka, Hideo; Himi, Kazuhisa [Nihon Univ., Tokyo. School of Medicine

    1983-04-01

    Utility of digital subtraction angiography (DSA) by fluorography was advocated with demonstrable clinical cases. DSA is drawing attention for use at the outpatient clinic because it is relatively noninvasive, involves less risk than that by catheterization, and can be performed by intravenous injection. It also has a number of advantages such as instantaneous imaging and possible imaging of multiple sites by the same procedure. It still be extensively used in clinical practice not only as a screening method, but also as a functional imaging one.

  10. Optoacoustic diagnostic modality: from idea to clinical studies with highly compact laser diode-based systems

    Science.gov (United States)

    Esenaliev, Rinat O.

    2017-09-01

    Optoacoustic (photoacoustic) diagnostic modality is a technique that combines high optical contrast and ultrasound spatial resolution. We proposed using the optoacoustic technique for a number of applications, including cancer detection, monitoring of thermotherapy (hyperthermia, coagulation, and freezing), monitoring of cerebral blood oxygenation in patients with traumatic brain injury, neonatal patients, fetuses during late-stage labor, central venous oxygenation monitoring, and total hemoglobin concentration monitoring as well as hematoma detection and characterization. We developed and built optical parametric oscillator-based systems and multiwavelength, fiber-coupled highly compact, laser diode-based systems for optoacoustic imaging, monitoring, and sensing. To provide sufficient output pulse energy, a specially designed fiber-optic system was built and incorporated in ultrasensitive, wideband optoacoustic probes. We performed preclinical and clinical tests of the systems and the optoacoustic probes in backward mode for most of the applications and in forward mode for the breast cancer and cerebral applications. The high pulse energy and repetition rate allowed for rapid data acquisition with high signal-to-noise ratio from cerebral blood vessels, such as the superior sagittal sinus, central veins, and peripheral veins and arteries, as well as from intracranial hematomas. The optoacoustic systems were capable of automatic, real-time, continuous measurements of blood oxygenation in these blood vessels.

  11. Optimising the diagnostic imaging process through clinical history documentation

    International Nuclear Information System (INIS)

    Egan, I.; Baird, M.

    2003-01-01

    In the United Kingdom the 1990s were characterised by radiographer role extension including radiographic reporting and the performance of a variety of contrast examinations. In Australia where a privatised health system constrains the role of radiographers, other ways need to be found to improve professional practice and enhance patient care. One such way is for radiographers to develop knowledge and skills in clinical history taking. The paper advocates the development of a formalised approach to clinical history taking that portrays the radiographer as a professional and advocate of patient rights and welfare. The paper examines history taking approaches used by other health care professionals and proposes a clinical history template using five key areas of interview: area and type of symptoms, current history, past history, special considerations and psychosocial/occupational history. Copyright (2003) Australian Institute of Radiography

  12. A comparison of arthrography to clinical diagnostics for diagnosing meniscal lesions

    International Nuclear Information System (INIS)

    Neuer, H.

    1982-01-01

    A comparative investigation as to the exactness of clinical and arthrographical diagnostics was carried out on 176 patients who were clinically examined and operated on in the period of 1972-1980. Using solely clinical diagnostics, the total rate of exactness was 90,9%, the exactness regarding the internal meniscal lesion being significantly higher (94.2%) than that regarding external meniscal lesion (76.7%). Using solely arthrographic diagnostics, the total rate of exactness was 82%, the rate for internal meniscus being significantly lower (83.9%) than that obtained using clinical diagnostics. As for the external meniscus, the exactness of arthrography differs only slightly from clinical diagnostics with 74.7%. The most frequent sources of error in arthorgraphy were found to be lesions of the posterior horn at the internal meniscus. In cases of external meniscal lesions, especially when an internal meniscal lesion was existing at the same time, both examination methods failed in 5 cases. For routine diagnosing of meniscal lesions, arthrography is not necessary. An accurate clinical examination and anamnesis bring very good and exact results and should therefore be given absolute priority. (orig./MG) [de

  13. Magnetic Nanoparticles From Fabrication to Clinical Applications

    CERN Document Server

    Thanh, Nguyen TK

    2012-01-01

    Offering the latest information in magnetic nanoparticle (MNP) research, Magnetic Nanoparticles: From Fabrication to Clinical Applications provides a comprehensive review, from synthesis, characterization, and biofunctionalization to clinical applications of MNPs, including the diagnosis and treatment of cancers. This book, written by some of the most qualified experts in the field, not only fills a hole in the literature, but also bridges the gaps between all the different areas in this field. Translational research on tailored magnetic nanoparticles for biomedical applications spans a variet

  14. B metastases in breast cancer. Clinical, diagnostic and therapeutic aspects

    International Nuclear Information System (INIS)

    Ferrigno, R.; Petitto, J.V.

    1989-01-01

    Osseous metastases are the most frequent sites of dissemination in breast cancer and diminish the quality of patients life, being one of the most serious problems of the disease. The authors discuss the clinical, diagnosis and therapeutic aspects, based on their own experience and data from the literature. (author)

  15. Clinical aspects of MR colonography as a diagnostic tool

    DEFF Research Database (Denmark)

    Achiam, Michael

    2010-01-01

    and that polypectomy might be curative. Colonoscopy remains the gold standard for full colon evaluation. However, the result of our studies can justify clinical use of MRC on selected indications, e.g. in the cases where colonoscopy is incomplete or technically difficult. Since up to 54% of all preoperative colon...

  16. Updated clinical diagnostic criteria for sporadic Creutzfeldt-Jakob disease

    NARCIS (Netherlands)

    I. Zerr; K. Kallenberg; D.M. Summers; C. Romero; A. Taratuto; U. Heinemann; M. Breithaupt; D. Varges; B. Meissner; A. Ladogana (Anna); M. Schuur (Maaike); S. Haik; S.J. Collins (Steven); G.H. Jansen (Gerard); G.B. Stokin; J. Pimentel; E. Hewer; D. Collie; P. Smith; H. Roberts; J.P. Brandel; P. Tikka-Kleemola (Päivi); M. Pocchiari (Maurizio); C. Begue; P. Cras (Patrick); R.G. Will; P. Sanchez-Juan (Pascual)

    2009-01-01

    textabstractSeveral molecular subtypes of sporadic Creutzfeldt-Jakob disease have been identified and electroencephalogram and cerebrospinal fluid biomarkers have been reported to support clinical diagnosis but with variable utility according to subtype. In recent years, a series of publications

  17. Schizoaffective disorder - The reliability of its clinical diagnostic use

    DEFF Research Database (Denmark)

    Vollmer-Larsen, A.; Jacobsen, T.B.; Hemmingsen, R.

    2006-01-01

    OBJECTIVE: Patients with psychoses often suffer from affective symptoms. The originally broad concept of schizoaffective disorder (SAD) has been significantly narrowed, transformed into a convoluted set of criteria both in the ICD-10 and DSM-IV. We examined the reliability of the clinical use...

  18. How to diagnose neuropathic pain? The contribution from clinical examination, pain questionnaires and diagnostic tests.

    Science.gov (United States)

    La Cesa, S; Tamburin, S; Tugnoli, V; Sandrini, G; Paolucci, S; Lacerenza, M; Marchettini, P; Cruccu, G; Truini, A

    2015-12-01

    Patients with peripheral and central nervous system diseases may suffer from different types of pain, namely nociceptive, neuropathic and mixed pain. Although in some cases, the distinction between these types of pain is clinically evident, yet in some patients an accurate differential diagnosis requires dedicated clinical examination, screening questionnaires and diagnostic techniques some of which are available only in specialized pain centres. This review briefly addresses the currently agreed definitions of the different types of pain and shows how clinical examination, pain questionnaires and diagnostic tests can help the clinicians in identifying neuropathic pain.

  19. Diagnostic value of patient characteristics, history, and six clinical tests for traumatic anterior shoulder instability

    NARCIS (Netherlands)

    van Kampen, D.A.; van den Berg, T.; van der Woude, H.J.; Castelein, R.M.; Terwee, C.B.; Willems, W.J.

    2013-01-01

    Background: It is unknown which combination of patient information and clinical tests might beoptimal for the diagnosis of traumatic anterior shoulder instability. This study aimed to determinethe diagnostic value of individual clinical tests and to develop a prediction model that combined patient

  20. Single and Combined Diagnostic Value of Clinical Features and Laboratory Tests in Acute Appendicitis

    NARCIS (Netherlands)

    Laméris, Wytze; van Randen, Adrienne; Go, Peter M. N. Y. H.; Bouma, Wim H.; Donkervoort, Sandra C.; Bossuyt, Patrick M. M.; Stoker, Jaap; Boermeester, Marja A.

    2009-01-01

    Objectives: The objective was to evaluate the diagnostic accuracy of clinical features and laboratory test results in detecting acute appendicitis. Methods: Clinical features and laboratory test results were prospectively recorded in a consecutive series of 1,101 patients presenting with abdominal

  1. Applications of laser diagnostics to thermal power plants and engines

    International Nuclear Information System (INIS)

    Deguchi, Y.; Kamimoto, T.; Wang, Z.Z.; Yan, J.J.; Liu, J.P.; Watanabe, H.; Kurose, R.

    2014-01-01

    The demands for lowering the burdens on the environment will continue to grow steadily. It is important to monitor controlling factors in order to improve the operation of industrial thermal systems. In engines, exhaust gas temperature and concentration distributions are important factors in nitrogen oxides (NO x ), total hydrocarbon (THC) and particulate matter (PM) emissions. Coal and fly ash contents are parameters which can be used for the control of coal-fired thermal power plants. Monitoring of heavy metals such as Hg is also important for pollution control. In this study, the improved laser measurement techniques using computed tomography-tunable diode laser absorption spectroscopy (CT-TDLAS), low pressure laser-induced breakdown spectroscopy (LIBS), and laser breakdown time-of-flight mass spectrometry (LB-TOFMS) have been developed and applied to measure 2D temperature and species concentrations in engine exhausts, coal and fly ash contents, and trace species measurement. The 2D temperature and NH 3 concentration distributions in engine exhausts were successfully measured using CT-TDLAS. The elemental contents of size-segregated particles were measured and the signal stability increased using LIBS with the temperature correction method. The detection limit of trace species measurement was enhanced using low pressure LIBS and LB-TOFMS. The detection limit of Hg can be enhanced to 3.5 ppb when employing N 2 as the buffer gas using low pressure LIBS. Hg detection limit was about 0.82 ppb using 35 ps LB-TOFMS. Compared to conventional measurement methods laser diagnostics has high sensitivity, high response and non-contact features for actual industrial systems. With these engineering developments, transient phenomena such as start-ups in thermal systems can be evaluated to improve the efficiency of these thermal processes. - Highlights: • Applicability of newly developed laser diagnostics was demonstrated for the improvement of thermal power plants and

  2. Real time CT-fluoroscopy: diagnostic and therapeutic applications

    International Nuclear Information System (INIS)

    Mey, J. de; Op de Beeck, B.; Meysman, M.; Noppen, M.; Maeseneer, M. de; Vanhoey, M.; Vincken, W.; Osteaux, M.

    2000-01-01

    The synergetic progression of CT technology and computer hardware has made ultrafast acquisition and image reconstruction possible. This has lead to the availability of CT interactive diagnosis and therapeutic procedures. Making use of our own material (337 intervention procedures during the last 17 months), we have compared our techniques and results to the recent literature data. One of the advantages of the biopsy technique is an improved sensitivity for neoplastic lesions, most certainly in cases of intrapulmonary lesions, surrounded by aerated tissue (now 94% compared to 87% in our previous study). A second advantage is the safety of the technique (only one major complication in our series). Fluid collection drainages, and more complex interventions like local injection of drugs, radio-frequency ablation, wire hook placement and ethanol injection were performed without complication. Yet another interesting feature is the shortening of the procedure time (reduced in average to an 'in-room' time of less than 30 min), which has definite economical implications. Furthermore it increases the patient's comfort and safety, and extends the scope of outpatient procedures (80% outpatient procedures in our material). On the other side the radiation exposure can be raised as an issue, especially when we consider the operator's hands. However, the described technique and the use of dedicated tools can alleviate the problem. As a conclusion, real time CT fluoroscopy has given a new input and broadens the scope of clinical indications of CT-guided diagnostic and therapeutic procedures

  3. Clinical applications of Gallium-68

    International Nuclear Information System (INIS)

    Banerjee, Sangeeta Ray; Pomper, Martin G.

    2013-01-01

    Gallium-68 is a positron-emitting radioisotope that is produced from a 68 Ge/ 68 Ga generator. As such it is conveniently used, decoupling radiopharmacies from the need for a cyclotron on site. Gallium-68-labeled peptides have been recognized as a new class of radiopharmaceuticals showing fast target localization and blood clearance. 68 Ga-DOTATOC, 8 Ga-DOTATATE, 68 Ga-DOTANOC, are the most prominent radiopharmaceuticals currently in use for imaging and differentiating lesions of various somatostatin receptor subtypes, overexpressed in many neuroendocrine tumors. There has been a tremendous increase in the number of clinical studies with 68 Ga over the past few years around the world, including within the United States. An estimated ∼10,000 scans are being performed yearly in Europe at about 100 centers utilizing 68 Ga-labeled somatostatin analogs within clinical trials. Two academic sites within the US have also begun to undertake human studies. This review will focus on the clinical experience of selected, well-established and recently applied 68 Ga-labeled imaging agents used in nuclear medicine. - Highlights: ► A summary of the emerging clinical uses of 68 Ga-based radiopharmaceuticals is provided. ► 68 Ga-PET may prove as or more clinically robust than the corresponding 18 F-labeled agents. ► 68 Ga-radiopeptides were studied for targeting of somatostatin receptors subtypes. ► 68 Ga-DOTATOC, 68 Ga-DOTATATE, 68 Ga-DOTANOC, are currently in clinical trials

  4. Clinical and radiological diagnostic of foreign bodies in companion birds

    International Nuclear Information System (INIS)

    Kummerfeld, N.; Erhorn, I.

    1991-01-01

    Sometimes curious foreign bodies placed in the proventriculus/ventriculus of companion birds are causes of single case diseases. Clinical signs include untypical symptoms such as distress, lameness, vomiting and diarrhoe. In cases of heavy metal intoxication, e.g. lead poisoning, CNS-disorders are found. Radiographs taken in a ventro-dorsal and a latero-lateral view show the presence of foreign bodies in suspicion. In most cases of foreign bodies in birds a surgical intervention (Gastrotomy) is indicated

  5. Clinical and diagnostic characteristics of hyperprolactinemia in childhood and adolescence.

    Science.gov (United States)

    Catli, Gonul; Abaci, Ayhan; Bober, Ece; Büyükgebiz, Atilla

    2013-01-01

    Pituitary adenoma is the most common cause of hyperprolactinemia, which is a rare endocrine disorder encountered in pediatric patient care. Epidemiological and clinical information about hyperprolactinemia in childhood and adolescence is limited. Clinical signs of hyperprolactinemia are very heterogeneous. In girls, disturbances in menstrual function and galactorrhea may be seen, whereas in boys, headache, visual disturbances, delayed pubertal development and hypogonadism are often present. Owing to the ease of ordering a serum prolactin measurement, an evidence-based, cost-effective approach to the management of this endocrine disorder is required. Before a diagnosis of hyperprolactinemia is made, drug use, renal insufficiency, hypothyroidism, and parasellar tumors should be excluded. The main objectives of treatment are normalization of prolactin level, adenoma shrinkage, and recovery from clinical signs related to hyperprolactinemia. In patients with microadenoma, invasive or non-invasive macroadenoma, and even in patients with visual field defects, dopamine agonists are the first-line treatment. Surgical treatment is indicated in patients who are unresponsive or intolerant to medical treatment or who have persistent neurological signs. Radiotherapy should be considered as a supportive treatment for patients in whom surgery fails or medical response is not achieved.

  6. Autoimmune thyroiditis goitrogenic. Aspects of clinical and laboratorial diagnostic

    International Nuclear Information System (INIS)

    Costa, H.F.Z. da.

    1986-01-01

    To asses the accuracy achieved by the A.C.A.T. and other clinical and laboratorial criterion in the diagnoses of T.A.I.B. we investigated twenty patients with goiter and antimicrossomal antibodies titres of 1/1.600 or more. Analysing the parameters useful in the diagnosis, we found a significant correlation between the antimicrossomal antibodies titres and the basal TSH concentration, an elevated basal TSH and an exaggerated response to TRH independent of the patient clinical status reflecting in the majority of the cases a state of subclinical hypotyroidism; an irregular appearance of the radioisotope thyroid scan and a positive response to a perchlorate discharge test. We conclude that from the parameters useful in the T.A.I.B. diagnosis, the A.C.A.T. detection mainly the antimicrossomal antibodies, is an excellent tool to detect patients with a clinical suspect of thyroid auto-immune disease and when we found high tires in a patient with goiter and an elevated basal TSH concentration we can suggest T.A.I.B. diagnosis. (author)

  7. Clinical utility of real-time compression ultrasonography for diagnostic management of patients with recurrent venous thrombosis

    NARCIS (Netherlands)

    Heijboer, H.; Jongbloets, L. M.; Büller, H. R.; Lensing, A. W.; ten Cate, J. W.

    1992-01-01

    In the diagnostic management of patients with clinically suspected recurrent deep-vein thrombosis (DVT), there are potential limitations to all available diagnostic techniques. Since venous abnormalities may persist for some time after an acute thrombosis, the usefulness of compression

  8. Diagnostic Accuracy of Clinical Examination and Imaging Findings for Identifying Subacromial Pain.

    Science.gov (United States)

    Cadogan, Angela; McNair, Peter J; Laslett, Mark; Hing, Wayne A

    2016-01-01

    The diagnosis of subacromial pathology is limited by the poor accuracy of clinical tests for specific pathologies. The aim of this study was to estimate the diagnostic accuracy of clinical examination and imaging features for identifying subacromial pain (SAP) defined by a positive response to diagnostic injection, and to evaluate the influence of imaging findings on the clinical diagnosis of SAP. In a prospective, diagnostic accuracy design, 208 consecutive patients presenting to their primary healthcare practitioner for the first time with a new episode of shoulder pain were recruited. All participants underwent a standardized clinical examination, shoulder x-ray series and diagnostic ultrasound scan. Results were compared with the response to a diagnostic block of xylocaineTM injected into the SAB under ultrasound guidance using ≥80% post-injection reduction in pain intensity as the positive anaesthetic response (PAR) criterion. Diagnostic accuracy statistics were calculated for combinations of clinical and imaging variables demonstrating the highest likelihood of a PAR. A PAR was reported by 34% of participants. In participants with no loss of passive external rotation, combinations of three clinical variables (anterior shoulder pain, strain injury, absence of symptoms at end-range external rotation (in abduction)) demonstrated 100% specificity for a PAR when all three were positive (LR+ infinity; 95%CI 2.9, infinity). A full-thickness supraspinatus tear on ultrasound increased the likelihood of a PAR irrespective of age (specificity 98% (95%CI 94, 100); LR+ 6.2; 95% CI 1.5, 25.7)). Imaging did not improve the ability to rule-out a PAR. Combinations of clinical examination findings and a full-thickness supraspinatus tear on ultrasound scan can help confirm, but not exclude, the presence of subacromial pain. Other imaging findings were of limited value for diagnosing SAP.

  9. A computational framework for converting textual clinical diagnostic criteria into the quality data model.

    Science.gov (United States)

    Hong, Na; Li, Dingcheng; Yu, Yue; Xiu, Qiongying; Liu, Hongfang; Jiang, Guoqian

    2016-10-01

    Constructing standard and computable clinical diagnostic criteria is an important but challenging research field in the clinical informatics community. The Quality Data Model (QDM) is emerging as a promising information model for standardizing clinical diagnostic criteria. To develop and evaluate automated methods for converting textual clinical diagnostic criteria in a structured format using QDM. We used a clinical Natural Language Processing (NLP) tool known as cTAKES to detect sentences and annotate events in diagnostic criteria. We developed a rule-based approach for assigning the QDM datatype(s) to an individual criterion, whereas we invoked a machine learning algorithm based on the Conditional Random Fields (CRFs) for annotating attributes belonging to each particular QDM datatype. We manually developed an annotated corpus as the gold standard and used standard measures (precision, recall and f-measure) for the performance evaluation. We harvested 267 individual criteria with the datatypes of Symptom and Laboratory Test from 63 textual diagnostic criteria. We manually annotated attributes and values in 142 individual Laboratory Test criteria. The average performance of our rule-based approach was 0.84 of precision, 0.86 of recall, and 0.85 of f-measure; the performance of CRFs-based classification was 0.95 of precision, 0.88 of recall and 0.91 of f-measure. We also implemented a web-based tool that automatically translates textual Laboratory Test criteria into the QDM XML template format. The results indicated that our approaches leveraging cTAKES and CRFs are effective in facilitating diagnostic criteria annotation and classification. Our NLP-based computational framework is a feasible and useful solution in developing diagnostic criteria representation and computerization. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Efficacy of clinical diagnostic procedures utilized in nuclear medicine. Nine month progress report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-01-01

    This study is designed to determine the efficacy of nuclear medicine procedures in clinical practice. Several methods of determining efficacy will be evaluated to determine those most suitable. Nuclear medicine methods will be confined to the study of lung diseases by pulmonary perfusion and ventilation. In addition to evaluating the above methods data will be obtained to determine the sensitivity, specificity, predictive value and efficiency of the test under consideration. These values, corrected for prevalence of the disease processes under consideration will then be compared to the values obtained by the MACRO and MICRO methods and will help to bound the clinical reliability of the diagnostic method depending on the degree to which the several methods trend together. Depending on the practicality of these two methods, in addition to the determination of efficacy, cost effectiveness factors and benefit-risk estimates which are used to apply to radiation effects will be determined for nuclear medicine studies of the brain, bone, heart, liver and thyroid subsequently. The measurement techniques will then be utilized to establish guidelines for the most useful applications of the given procedure so that clinicians will be able to obtain a pretest estimate of the utility of the nuclear medicine test.

  11. Clinical and diagnostic characteristics of patients with suspected polyneuropathy

    Directory of Open Access Journals (Sweden)

    Mikhailova Е.V.

    2013-09-01

    Full Text Available Objective: to study the causes and clinical manifestations of disease in children referred for hospitalization in children infectious diseases hospital in Saratov with a diagnosis of «acute flaccid paralysis». Material and methods: 157 children with the diagnosis on admission of the guide «acute flaccid paralysis». Conducted clinical examination and laboratory tests included a general analysis of cerebrospinal fluid, urine, virological examination of nasal swabs and faeces, with the definition of a serological ELISA method and RPHA immunoglobulins to influenza, rubella, and enterovirus, immunological study of blood, cerebrospinal fluid PCR, electromyography of the affected limbs. Results. 77 patients (49% with the disease associated with the violation of the musculoskeletal system were registered. In the other cases revealed polyneuropathy was not of poliovirus etiology. Etiological nature of the disease could be explained by 54% of patients. In 37 (46% patients the diagnosis was formulated in accordance with the severity of paralysis. One child was diagnosed with a vaccine-associated poliomyelitis. Conclusion. The diagnosis of «acute flaccid paralysis» used as administered requires a detailed interpretation in a hospital.

  12. Educational and Scientific Applications of Climate Model Diagnostic Analyzer

    Science.gov (United States)

    Lee, S.; Pan, L.; Zhai, C.; Tang, B.; Kubar, T. L.; Zhang, J.; Bao, Q.

    2016-12-01

    Climate Model Diagnostic Analyzer (CMDA) is a web-based information system designed for the climate modeling and model analysis community to analyze climate data from models and observations. CMDA provides tools to diagnostically analyze climate data for model validation and improvement, and to systematically manage analysis provenance for sharing results with other investigators. CMDA utilizes cloud computing resources, multi-threading computing, machine-learning algorithms, web service technologies, and provenance-supporting technologies to address technical challenges that the Earth science modeling and model analysis community faces in evaluating and diagnosing climate models. As CMDA infrastructure and technology have matured, we have developed the educational and scientific applications of CMDA. Educationally, CMDA supported the summer school of the JPL Center for Climate Sciences for three years since 2014. In the summer school, the students work on group research projects where CMDA provide datasets and analysis tools. Each student is assigned to a virtual machine with CMDA installed in Amazon Web Services. A provenance management system for CMDA is developed to keep track of students' usages of CMDA, and to recommend datasets and analysis tools for their research topic. The provenance system also allows students to revisit their analysis results and share them with their group. Scientifically, we have developed several science use cases of CMDA covering various topics, datasets, and analysis types. Each use case developed is described and listed in terms of a scientific goal, datasets used, the analysis tools used, scientific results discovered from the use case, an analysis result such as output plots and data files, and a link to the exact analysis service call with all the input arguments filled. For example, one science use case is the evaluation of NCAR CAM5 model with MODIS total cloud fraction. The analysis service used is Difference Plot Service of

  13. Clinical application of fast neutrons

    International Nuclear Information System (INIS)

    Battermann, J.J.

    1981-01-01

    The results of treatments and clinical experiments with neutrons (from a medical d+T neutron generator with an output of 10 12 neutrons per second) are reported and discussed. Data on RBE values are presented after single doses and multiple fractions of neutrons and 60 Co-gamma rays on pulmonary metastases. The results of pilot studies on head and neck tumours, brain tumours and pelvic tumours are discussed. The accuracy of the calculated dose is tested with some in-vivo experiments during neutron irradiation of the pelvis. Estimations of RBE values for tumour control, skin damage and intestinal damage after fractionated neutron therapy are dealt with and the results obtained in treatment of sarcomas are discussed. The preliminary results are given of some clinical trials in Amsterdam. Also some data from other centres are reviewed. From these data some remarks about the future of neutron therapy are made. (Auth.)

  14. State-of-art application of near infrared spectroscopy for functional diagnostics in neonatology

    International Nuclear Information System (INIS)

    Wolf, M.; Paiziev, A.

    2013-01-01

    The present brief review is devoted to application of near infra-red spectroscopy (NIRS) for early diagnostics of human brain injury. The number of commercially accessible NIRS instruments, and accordingly their users, increases but the precision of measurements and their reproducibility from the clinical point of view essentially depend on used algorithms, a kind of the NIRS-instrument, sensors, which frequently leads to the different values of the measurable parameters of blood oxygen saturation (StO 2 ). We present some commercially accessible NIRS instruments for control of an oxygen saturation degree in human blood, first of all in neonatology, on the basis of absorption and scattering of near infra-red light at human tissue chromophores. The results of clinical investigations of different NIRS-spectrometers for measurements of in-vivo new-born child' blood saturation are presented as well. (authors)

  15. Clinics in diagnostic imaging (179). Severe rhabdomyolysis complicated by myonecrosis.

    Science.gov (United States)

    Kok, Shi Xian Shawn; Tan, Tien Jin

    2017-08-01

    A 32-year-old man presented to the emergency department with severe right lower limb pain and swelling of three days' duration. He had multiple prior admissions for recurrent seizures and suicide attempts. Markedly elevated serum creatine kinase levels and urine myoglobinuria were consistent with a diagnosis of rhabdomyolysis. Initial magnetic resonance imaging of the right lower limb revealed diffuse muscle oedema and features of myositis in the gluteal muscles and the adductor, anterior and posterior compartments of the thigh. Follow-up magnetic resonance imaging performed 11 days later showed interval development of areas of myonecrosis and haemorrhage. The causes, clinical presentation and imaging features of rhabdomyolysis are discussed. Copyright: © Singapore Medical Association.

  16. [Diagnostic strategy in patients with clinically suspected deep vein thrombosis

    DEFF Research Database (Denmark)

    Mantoni, Margit Yvonne; Kristensen, M.; Brogaard, M.H.

    2008-01-01

    INTRODUCTION: The standard method for diagnosing deep vein thrombosis (DVT) involves determination of D-dimer and ultrasound scanning. In an attempt to reduce the number of ultrasound examinations we have supplemented this with a clinical probability estimate for DVT (DVT-score) over one year....... MATERIALS AND METHODS: A total of 508 consecutive patients presenting in the emergency room with suspected DVT had D-dimer and DVT-score performed. Patients with non-elevated D-dimer and a low or moderate DVT score received no treatment. The remainder had ultrasound scanning from the groin to the popliteal...... patients with normal D-dimer had high DVT-scores, none had DVT, so that the benefit from determining DVT-scores was modest. Ultrasound scanning revealed DVT in 85 out of 397 patients with elevated D-dimer. A repeat examination was performed in 91 patients with persisting symptoms, and disclosed DVT in two...

  17. Severe scrub typhus infection: Clinical features, diagnostic challenges and management

    Science.gov (United States)

    Peter, John Victor; Sudarsan, Thomas I; Prakash, John Anthony J; Varghese, George M

    2015-01-01

    Scrub typhus infection is an important cause of acute undifferentiated fever in South East Asia. The clinical picture is characterized by sudden onset fever with chills and non-specific symptoms that include headache, myalgia, sweating and vomiting. The presence of an eschar, in about half the patients with proven scrub typhus infection and usually seen in the axilla, groin or inguinal region, is characteristic of scrub typhus. Common laboratory findings are elevated liver transaminases, thrombocytopenia and leukocytosis. About a third of patients admitted to hospital with scrub typhus infection have evidence of organ dysfunction that may include respiratory failure, circulatory shock, mild renal or hepatic dysfunction, central nervous system involvement or hematological abnormalities. Since the symptoms and signs are non-specific and resemble other tropical infections like malaria, enteric fever, dengue or leptospirosis, appropriate laboratory tests are necessary to confirm diagnosis. Serological assays are the mainstay of diagnosis as they are easy to perform; the reference test is the indirect immunofluorescence assay (IFA) for the detection of IgM antibodies. However in clinical practice, the enzyme-linked immuno-sorbent assay is done due to the ease of performing this test and a good sensitivity and sensitivity when compared with the IFA. Paired samples, obtained at least two weeks apart, demonstrating a ≥ 4 fold rise in titre, is necessary for confirmation of serologic diagnosis. The mainstay of treatment is the tetracycline group of antibiotics or chloramphenicol although macrolides are used alternatively. In mild cases, recovery is complete. In severe cases with multi-organ failure, mortality may be as high as 24%. PMID:26261776

  18. Evidence of clinical utility: an unmet need in molecular diagnostics for patients with cancer.

    Science.gov (United States)

    Parkinson, David R; McCormack, Robert T; Keating, Susan M; Gutman, Steven I; Hamilton, Stanley R; Mansfield, Elizabeth A; Piper, Margaret A; Deverka, Patricia; Frueh, Felix W; Jessup, J Milburn; McShane, Lisa M; Tunis, Sean R; Sigman, Caroline C; Kelloff, Gary J

    2014-03-15

    This article defines and describes best practices for the academic and business community to generate evidence of clinical utility for cancer molecular diagnostic assays. Beyond analytical and clinical validation, successful demonstration of clinical utility involves developing sufficient evidence to demonstrate that a diagnostic test results in an improvement in patient outcomes. This discussion is complementary to theoretical frameworks described in previously published guidance and literature reports by the U.S. Food and Drug Administration, Centers for Disease Control and Prevention, Institute of Medicine, and Center for Medical Technology Policy, among others. These reports are comprehensive and specifically clarify appropriate clinical use, adoption, and payer reimbursement for assay manufacturers, as well as Clinical Laboratory Improvement Amendments-certified laboratories, including those that develop assays (laboratory developed tests). Practical criteria and steps for establishing clinical utility are crucial to subsequent decisions for reimbursement without which high-performing molecular diagnostics will have limited availability to patients with cancer and fail to translate scientific advances into high-quality and cost-effective cancer care. See all articles in this CCR Focus section, "The Precision Medicine Conundrum: Approaches to Companion Diagnostic Co-development." ©2014 AACR.

  19. [Hysteroscopy clinic: diagnostic and therapeutic method in abnormal uterine bleeding].

    Science.gov (United States)

    Alanis Fuentes, José; Obregón Zegarra, Eva Haydee

    2012-12-01

    Abnormal uterine bleeding is a public health problem prevalence exceeded only by abnormal vaginal discharge as a reason for medical consultation. To describe the findings reported by the Hysteroscopy clinic of the Hospital GEA Gonzalez on patients with Abnormal Uterine bleeding diagnosis. Retrospective, transversal, descriptive study. The total 2546 records of those patient that were evaluated by Office Hysteroscopic between January 2007 and December 2008 on the Hysteroscopy Clinic of Hospital Manuel GEA Gonzalez, then we selected the 1482 records of those patients that were sended because of an Abnormal Uterine bleeding condition. We descrive the frequencies of the diagnosis and its interrelation with the age of the patients. We also report the therapeutical interventions during office hysteroscopy. The mean age of the patients was 42.15 +/- 9.30 years (from 12 a 92 years); the age groups of patients that belonged to 40-44 years and 45-49 years are the most frequent patient and they represent the 25% y el 23.3% of the records. The abnormal findings occurred on the 66% de of the patients. Those patients of 65 years old and older do not have any report of normal cavities, all of then have abnormal findings. The leiomyoma (26.9%) and the endometrial polyps (27.3%) were the most frequent findings. The postmenopausal bleeding had a rate of 90.9% abnormal findings and in this group of patients the most frequent diagnosis was atrophic endometrium (32.2%) and polyps (24.3%). Besides that the office hysteroscopy show its therapeutical usefulness because of the 67% and 77.5% of polipectomy perform for endometrial and cervical polyps respectively The office Hysteroscopy is a well tolerated diagnosis and therapeutic method that is useful for any women with abnormal uterine bleeding condition and it is the ideal technique for the examination of abnormal uterine bleeding in postmenopausal women... The office hysteroscopy is a efficient cost-effective and cost-benefic method for

  20. The Diagnostic and Prognostic Value of a Dual-Tasking Paradigm in a Memory Clinic

    DEFF Research Database (Denmark)

    Nielsen, Malene Schjnning; Simonsen, Anja Hviid; Siersma, Volkert

    2018-01-01

    -tasking paradigm, such as the Timed Up and Go-Dual Task (TUG-DT), may be useful in the diagnostic assessment of mild cognitive impairment (MCI). OBJECTIVE: To investigate the diagnostic and prognostic ability of a dual-tasking paradigm in patients with MCI or mild Alzheimer's disease (AD) and to evaluate...... the association between the dual-tasking paradigm and cerebrospinal fluid (CSF) AD biomarkers. METHODS: The study is a prospective cohort study conducted in a clinical setting in two memory clinics. Eighty-six patients were included (28 MCI, 17 AD, 41 healthy controls (HC)). The ability to perform dual...

  1. Cranial MRI: Current clinical applications

    International Nuclear Information System (INIS)

    Bradley, W.G. Jr.; Kortman, K.E.

    1987-01-01

    Human MR images were first published by the Nottingham group in 1980. Since that time, there have been steady improvements in image quality and significant reductions in imaging time. After initial studies by the Hammersmith group in London, investigators at UCSF published studies comparing CT with MR, clearly demonstrating the higher sensitivity of MR to pathologic intracranial processes. Since that time, several investigators have demonstrated the efficacy of MR in the evaluation of a wide range of intracranial pathologic processes, including neoplasms, demyelinating disease, trauma, and congenital abnormalities. In the authors' studies comparing MR with CT in 400 consecutive cases of suspected CNS pathology, MR detected abnormalities which were not seen on CT in 30 percent of these cases. MR has become established as the imaging modality of choice in the evaluation of a broad range of CNS abnormalities and is rapidly being implemented not only at university medical centers but also in community hospitals and free-standing clinics. This chapter deals with fundamental principles of MR image interpretation and provides insight into current clinical indications for MR in intracranial disorders

  2. Lead intoxication: clinic and diagnostic evaluation in children

    Directory of Open Access Journals (Sweden)

    Martínez-Riera Nora

    2012-03-01

    Full Text Available Poverty, poor nutrition, environmental and social injustice prevailing in Latin America are factorsthat determine the action of pollutants on children. Lead poisoning and pollution constitute apublic health problem throughout the world. Lead affects multiple organs: nervous system particularly,hematopoietic, renal, endocrine, bone and others. Objective: to assess clinical, biochemicaland vascular effects in children exposed to known source of lead. Materials and methods: Sevenchildren with defined source lead exposure were studied, general and specific lead laboratorywere made. Endothelial function and electrocardiographic parameters were assessed. Statistic:descriptive. Results: Age average was 6,2 years (DE± 1, 6, average haematocrit 31% (DE±0,02;hemoglobin average 10,2 g/dl (DE± 0,78. 100% presented hypochromia, microcitosis, anemiaand marked anisocytosis. Lead average: 37,9 ug/dl (DE±6,22, ALA-D average: 8,9 U/L (DE±4,5.No changes were found in lipid profile and kidney function. All presented microalbuminuriaand endothelial dysfunction. Conclusion: These results show the effects of environmental leadexposure that can result in children not occupationally exposed.

  3. Metallic radionuclides: applications in diagnostic and therapeutic nuclear medicine

    International Nuclear Information System (INIS)

    Weiner, R.E.; Thakur, M.L.

    1995-01-01

    Nuclear Medicine is a medical modality that utilizes radioactivity (radiopharmaceutical) to diagnose and treat disease. Radiopharmaceuticals contain a component which directs the radionuclide to the desire physiological target. For diagnostic applications, these nuclides must emit a γ ray that can penetrate the body and can be detected externally while for therapeutic purposes nuclides are preferred that emit β particles and deliver highly localized tissue damage. 67 Ga citrate is employed to detect chronic occult abscesses, Hodgkin's and non-Hodgkin's lymphomas, lung cancer, hepatoma and melanoma and localizes in these tissues utilizing iron-binding proteins. 201 Thallous chloride, a potassium analogue, used to diagnosis coronary artery disease, is incorporated in muscle tissue via the Na + -K + -ATPase. 111 In labeled autologous white blood cells, used for the diagnosis of acute infections and inflammations, takes advantage of the white cell's role in fighting infections. 111 In is incorporated in other radiopharmaceuticals e.g. polyclonal IgG, OncoScint CR/OV, OctreoScan and Myoscint by coupling diethylenetriaminepentaacetic acid, a chelate, covalently to these molecules. OncoScint CR/OV and Myoscint localize by antigen-antibody interactions while OctreoScan is taken up by malignant cells in a receptor based process. Polyclonal IgG may share some localization characteristics with 67 Ga. 89 Sr, a pure β emitter, is used for palliation of bone pain due to metastatic bone lesions. Bone salts [Ca(PO) 4 ] are increased in these lesions and this radionuclide is taken up similarly to Ca 2+ . 186 Re and 153 Sm bound to polydentate phosphonate chelates are used similarly and follow the phosphate pathway in lesion incorporation. (orig.)

  4. Metallic radionuclides: Applications in diagnostic and therapeutic nuclear medicine

    International Nuclear Information System (INIS)

    Werner, R.E.; Thakur, M. L.

    1997-01-01

    Nuclear Medicine is a medical modality that utilizes radioactivity (radiopharmaceutical) to diagnose and treat disease. Radiopharmaceuticals contain a component which directs the radionuclide to the desire physiological target. For diagnostic applications, these nuclides must emit a gamma ray that can penetrate the body and can be detected externally while for therapeutic purposes nuclides are preferred that emit beta particles and deliver highly localized tissue damage. sup 6 sup 7 Ga citrate is employed to detect chronic occult abscesses, Hodgkin's and non-Hodgkin's lymphomas, lung cancer, hepatoma and melanoma and localizes in these tissues utilizing iron-binding proteins. sup 2 sup 0 sup 1 Thallous chloride, a potassium analogue, used to diagnosis coronary artery disease, is incorporated in muscle tissue via the Na sup + -K sup + -ATPase. sup 1 sup 1 sup 1 In labeled autologous white blood cells, used for the diagnosis of acute infections and inflammations, takes advantage of the white cell's role in fighting infections. sup 1 sup 1 sup 1 In is incorporated in other radiopharmaceuticals e.g. polyclonal IgG, OncoScint CR/OV, OctreoScan and Myoscint by coupling diethylenetriaminepentaacetic acid, a chelate, covalently to these molecules. OncoScint CR/OV and Myoscint localize by antigen-antibody interactions while OctreoScan is taken up by malignant cells in a receptor based process. Polyclonal IgG may share some localization characteristics with sup 6 sup 7 Ga. sup 8 sup 9 Sr, a pure beta emitter, is used for palliation of bone pain due to metastatic bone lesions. Bone salts [Ca(PO) sub 4] are increased in these lesions and this radionuclide is taken up similarly to Ca sup 2 sup +. sup 1 sup 8 sup 6 Re and sup 1 sup 5 sup 3 Sm bound to polydentate phosphonate chelates are used similarly and follow the phosphate pathway in lesion incorporation. (author)

  5. Neurogenetics in Argentina: diagnostic yield in a personalized research based clinic.

    Science.gov (United States)

    Rodríguez-Quiroga, Sergio Alejandro; Cordoba, Marta; González-Morón, Dolores; Medina, Nancy; Vega, Patricia; Dusefante, Cecilia Vazquez; Arakaki, Tomoko; Garretto, Nélida Susana; Kauffman, Marcelo Andres

    2015-01-01

    As a whole neurogenetic diseases are a common group of neurological disorders. However, the recognitionand molecular diagnosis of these disorders is not always straightforward. Besides, there is a paucity of informationregarding the diagnostic yield that specialized neurogenetic clinics could obtain. We performed a prospective,observational, analytical study of the patients seen in a neurogenetic clinic at a tertiary medicalcentre to assess the diagnostic yield of a comprehensive diagnostic evaluation that included a personalizedclinical assessment along with traditional and next-generation sequencing diagnostic tests. We included a cohortof 387 patients from May 2008 to June 2014. For sub-group analysis we selected a sample of patientswhose main complaint was the presence of progressive ataxia, to whom we applied a systematic moleculardiagnostic algorithm. Overall, a diagnostic mutation was identified in 27·4% of our cohort. However, if weonly considered those patients where a molecular test could be performed, the success rate rises to 45%. Weobtained diagnostic yields of 23·5 and 57·5% in the global group of ataxic patients and in the subset of ataxicpatients with a positive family history, respectively. Thus, about a third of patients evaluated in a neurogeneticclinic could be successfully diagnosed.

  6. Applications of stable isotopes in clinical pharmacology

    NARCIS (Netherlands)

    Schellekens, Reinout C A; Stellaard, Frans; Woerdenbag, Herman J; Frijlink, Henderik W; Kosterink, Jos G W

    2011-01-01

    This review aims to present an overview of the application of stable isotope technology in clinical pharmacology. Three main categories of stable isotope technology can be distinguished in clinical pharmacology. Firstly, it is applied in the assessment of drug pharmacology to determine the

  7. HYPOPARATHYROIDISM: ETIOLOGY, CLINICAL MANIFESTATION, CURRENT DIAGNOSTICS AND TREATMENT

    Directory of Open Access Journals (Sweden)

    N. G. Mokrysheva

    2016-01-01

    treatment with recombinant PTH is not widely used. Replacement therapy with recombinant human PTH is a  promising area, especially in severe clinical cases, refractory to conventional treatment.

  8. Development and clinical evaluation of a rapid diagnostic kit for feline leukemia virus infection.

    Science.gov (United States)

    Kim, Won-Shik; Chong, Chom-Kyu; Kim, Hak-Yong; Lee, Gyu-Cheol; Jeong, Wooseog; An, Dong-Jun; Jeoung, Hye-Young; Lee, Jae-In; Lee, Young-Ki

    2014-01-01

    Feline leukemia virus (FeLV) causes a range of neoplastic and degenerative diseases in cats. To obtain a more sensitive and convenient diagnosis of the disease, we prepared monoclonal antibodies specific for the FeLV p27 to develop a rapid diagnostic test with enhanced sensitivity and specificity. Among these antibodies, we identified two clones (hybridomas 8F8B5 and 8G7D1) that specifically bound to FeLV and were very suitable for a diagnostic kit. The affinity constants for 8F8B5 and 8G7D1 were 0.35 × 10⁸ and 0.86 × 10⁸, respectively. To investigate the diagnostic abilities of the rapid kit using these antibodies, we performed several clinical studies. Assessment of analytical sensitivity revealed that the detection threshold of the rapid diagnostic test was 2 ng/mL for recombinant p27 and 12.5 × 10⁴ IU/mL for FeLV. When evaluating 252 cat sera samples, the kit was found to have a kappa value of 0.88 compared to polymerase chain reaction (PCR), indicating a significant correlation between data from the rapid diagnostic test and PCR. Sensitivity and specificity of the kit were 95.2% (20/21) and 98.5% (257/261), respectively. Our results demonstrated that the rapid diagnostic test would be a suitable diagnostic tool for the rapid detection of FeLV infection in cats.

  9. [Diagnostics of the genetic causes of autism spectrum disorders - a clinical geneticist's view].

    Science.gov (United States)

    Szczaluba, Krzysztof

    2014-01-01

    Explanation of the genetic basis of autism spectrum disorders has, for many decades, been a part of interest of researchers and clinicians. In recent years, thanks to modern molecular and cytogenetic techniques, a significant progress has been achieved in the diagnosis of genetic causes of autism. This applies particularly, but not exclusively, to those cases of autism that are accompanied by other clinical signs (i. e. complex phenotypes). The important clinical markers belong to different categories, and include congenital defects/anomalies, dysmorphism and macro-/microcephaly, to name the few. Thus, the choice of the diagnostic strategy depends on the clinical and pedigree information and, under Polish circumstances, the availability of specific diagnostic techniques and the amount of reimbursement under the National Health Service. Overall, the identification of the genetic causes of autism spectrum disorders is possible in about 10-30% of patients. In this paper the practical aspects of the use of different diagnostic techniques are briefly described. Some clinical examples and current recommendations for the diagnosis of patients with autism spectrum disorders are also presented. The point of view of a specialist in clinical genetics, increasingly involved, as part of the multidisciplinary care team, in the diagnostics of an autistic child has been demonstrated.

  10. Modified diagnosis of cardiovascular diseases: Application and comparison of diagnostic techniques in clinical medicine, radiology, ultrasonography and nuclear medicine. Final report. Einsatz und Vergleich klinischer, roentgenologischer, sonographischer und nuklearmedizinischer Methoden zur abgestuften Diagnostik von Herzkrankheiten. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Adam, W.; Boettcher, D.; Christl, H.; Baew-Christow, T.; Holper, H.; Meindl, S.; Meyer, U.; Pfannenstiel, P.

    1985-01-01

    The main point of interest of the project is the question whether ultrasonography, myocardial scintiscanning, and radionuclide angiocardiography can replace the invasive techniques of cardiovascular diagnosis, and thus save costs at that. The results show that the above non-invasive techniques are indispensable in case of a diagnosis for cardiosurgery, almost sufficient in case of valvular heart disease, and sufficient in all cases of cardiomyopathy. Optimally planned application of the non-invasive methods could save about DM 7.3 millions a year in the FRG. (TRV).

  11. Diagnostics developments and applications for laser fusion experiments

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1977-01-01

    Some diagnostics techniques applied to current laser fusion target experiments are reviewed. Specifically, holographic interferometry of target plasmas, coded aperture imaging of thermonuclear alpha-particles and neutron energy spectrum measurements are discussed

  12. Application of statistical process control to qualitative molecular diagnostic assays

    LENUS (Irish Health Repository)

    O'Brien, Cathal P.

    2014-11-01

    Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control (SPC). Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply SPC to an assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater sample numbers to mitigate a protracted time to detection. Modeled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of SPC to qualitative laboratory data.

  13. Application of statistical process control to qualitative molecular diagnostic assays.

    Science.gov (United States)

    O'Brien, Cathal P; Finn, Stephen P

    2014-01-01

    Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control (SPC). Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply SPC to an assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater sample numbers to mitigate a protracted time to detection. Modeled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of SPC to qualitative laboratory data.

  14. Applications of ROC analysis in diagnostic image evaluation

    International Nuclear Information System (INIS)

    Metz, C.E.

    1979-01-01

    The need for Receiver Operating Characteristic (ROC) analysis is indicated by a discussion of the limitations of accuracy and of sensitivity and specificity as indices of diagnostic detection or discrmination performance. The concept of a variable decision threshold is shown to lead in a natural way to the ROC curve as a means for specifying diagnostic performance. Practical techniques for measuring ROC curves are described, and directions for possible generalizations of conventional ROC analysis are indicated

  15. Clinical application of TDF concept

    International Nuclear Information System (INIS)

    Tsujii, Hirohiko; Kamada, Tadashi; Irie, Goro

    1987-01-01

    Our clinical data has demonstrated that the NSD-TDF concept is valid in evaluation of radiation response in terms of predicting the total dose required to produce normal-tissue injury and local tumor control. However, in certain type of tumors such as maxillary cancers and esophagus cancers, the probability of tumor control was reversely related to the TDF values at about 120 to 130. This raises a potential possibility of ''supralethal phenomenon'' that is defined as a concomitant presence of recurrent tumor and radiation-induced necrotic tissue after high-dose irradiation. There has been accumulated data suggesting that the exponents of overall time (0.11) in NSD formula might yield a wrong shape of dose-response curve, resulting in a failure in prediction of late damage. However, it is considered that the NSD-TDF concept is still a practical model as far as it is used as a clue for calculation of alternative fractionation in daily radiotherapy. (author)

  16. A novel, non-invasive diagnostic clinical procedure for the determination of an oxygenation status of chronic lower leg ulcers using peri-ulceral transcutaneous oxygen partial pressure measurements: results of its application in chronic venous insufficiency (CVI).

    Science.gov (United States)

    Barnikol, Wolfgang K R; Pötzschke, Harald

    2012-01-01

    -called mosaic wounds. The hypoxia grades found in all of the chronic wounds was seen to be evenly distributed with values ranging from 0 to 40 mmHg, and therefore extremely inhomogeneous. In terms of oxygenation, chronic wounds are therefore inhomogeneous in two respects: (1) within the wound itself (intra-individual wound inhomogeneity) and (2) between different wounds (inter-individual wound inhomogeneity). Due to the extreme oxygen inhomogeneity, single measurements are not diagnostically useful. In healthy individuals the oxygen inhalation challenge (see above) results in synchronised tcPO(2) oscillations occurring at minute rhythms, which are not seen in CVI wounds. These oscillations can be interpreted as a sign of a functioning arterial vasomotor system.The new procedure is suitable for the routine characterisation of chronic wounds in terms of their oxygen status, and correspondingly, their metabolically determining (and limiting) potential for healing and regeneration. The oxygen characteristic K-PO(2) can furthermore be used as a warning of impending ulceration, since the oxygen provision worsens over time prior to the demise of the ulcerated tissue, thus making a controlled prophylaxis possible.

  17. Clinical reasoning in the real world is mediated by bounded rationality: implications for diagnostic clinical practice guidelines.

    Science.gov (United States)

    Bonilauri Ferreira, Ana Paula Ribeiro; Ferreira, Rodrigo Fernando; Rajgor, Dimple; Shah, Jatin; Menezes, Andrea; Pietrobon, Ricardo

    2010-04-20

    Little is known about the reasoning mechanisms used by physicians in decision-making and how this compares to diagnostic clinical practice guidelines. We explored the clinical reasoning process in a real life environment. This is a qualitative study evaluating transcriptions of sixteen physicians' reasoning during appointments with patients, clinical discussions between specialists, and personal interviews with physicians affiliated to a hospital in Brazil. FOUR MAIN THEMES WERE IDENTIFIED: simple and robust heuristics, extensive use of social environment rationality, attempts to prove diagnostic and therapeutic hypothesis while refuting potential contradictions using positive test strategy, and reaching the saturation point. Physicians constantly attempted to prove their initial hypothesis while trying to refute any contradictions. While social environment rationality was the main factor in the determination of all steps of the clinical reasoning process, factors such as referral letters and number of contradictions associated with the initial hypothesis had influence on physicians' confidence and determination of the threshold to reach a final decision. Physicians rely on simple heuristics associated with environmental factors. This model allows for robustness, simplicity, and cognitive energy saving. Since this model does not fit into current diagnostic clinical practice guidelines, we make some propositions to help its integration.

  18. Clinical reasoning in the real world is mediated by bounded rationality: implications for diagnostic clinical practice guidelines.

    Directory of Open Access Journals (Sweden)

    Ana Paula Ribeiro Bonilauri Ferreira

    Full Text Available BACKGROUND: Little is known about the reasoning mechanisms used by physicians in decision-making and how this compares to diagnostic clinical practice guidelines. We explored the clinical reasoning process in a real life environment. METHOD: This is a qualitative study evaluating transcriptions of sixteen physicians' reasoning during appointments with patients, clinical discussions between specialists, and personal interviews with physicians affiliated to a hospital in Brazil. RESULTS: FOUR MAIN THEMES WERE IDENTIFIED: simple and robust heuristics, extensive use of social environment rationality, attempts to prove diagnostic and therapeutic hypothesis while refuting potential contradictions using positive test strategy, and reaching the saturation point. Physicians constantly attempted to prove their initial hypothesis while trying to refute any contradictions. While social environment rationality was the main factor in the determination of all steps of the clinical reasoning process, factors such as referral letters and number of contradictions associated with the initial hypothesis had influence on physicians' confidence and determination of the threshold to reach a final decision. DISCUSSION: Physicians rely on simple heuristics associated with environmental factors. This model allows for robustness, simplicity, and cognitive energy saving. Since this model does not fit into current diagnostic clinical practice guidelines, we make some propositions to help its integration.

  19. Clinical Application of Wedge Factor

    International Nuclear Information System (INIS)

    Choi, Dong Rak; Ahn, Yong Chan; Huh, Sueng Jae

    1995-01-01

    Purpose : In general. The wedge factors which are used clinical practices are ignored of dependency on field sizes and depths. In this present, we investigated systematically the depth and field size dependency to determine the absorbed dose more accurately. Methods : The wedge factors for each wedge filter were measured at various depth (depth of Dmax, 5cm, 10cm, and 15cm) and field sizes (5 X 5cm, 10 X 10cm, 15 X 15cm, 20 X 20 cm) by using 4-,6-, and 10-MV X rays. By convention, wedge factors are determined by taking the ratio of the central axis ionization readings when the wedge filter is in place to those of the open field in same field size and measurement depth. In this present work, we determined the wedge factors for 4-, 6-, and 10-MV X rays from Clinac 600C and 2100C linear accelerators (manufactured by Varian Associates, Inc., Palo Alto, CA). To confirm that the wedge was centered., measurements were done with the two possible wedge position and various collimator orientations. Results : The standard deviations of measured values are within 0.3% and the depth dependence of wedge factor is greater for the lower energies. Especially, the variation of wedge factor is no less than 5% for 4- and 6- MV X rays with more than 45 .deg. wedge filter. But there seems to be a small dependence on field size. Conclusion : The results of this study show a dependence on the point of measurement. There also seems to be a small dependence on field size. And so, we should consider the depth and field size dependence in determining the wedge factors. If one wedge factor were to be used for each wedge filter, it seems that the measurement for a 10cm X 10cm field size at a depth of 10cm would be a reasonable choice

  20. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology (Spanish Edition); Capacitacion clinica de fisicos medicos especialistas en radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-01-15

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  1. XML, Ontologies, and Their Clinical Applications.

    Science.gov (United States)

    Yu, Chunjiang; Shen, Bairong

    2016-01-01

    The development of information technology has resulted in its penetration into every area of clinical research. Various clinical systems have been developed, which produce increasing volumes of clinical data. However, saving, exchanging, querying, and exploiting these data are challenging issues. The development of Extensible Markup Language (XML) has allowed the generation of flexible information formats to facilitate the electronic sharing of structured data via networks, and it has been used widely for clinical data processing. In particular, XML is very useful in the fields of data standardization, data exchange, and data integration. Moreover, ontologies have been attracting increased attention in various clinical fields in recent years. An ontology is the basic level of a knowledge representation scheme, and various ontology repositories have been developed, such as Gene Ontology and BioPortal. The creation of these standardized repositories greatly facilitates clinical research in related fields. In this chapter, we discuss the basic concepts of XML and ontologies, as well as their clinical applications.

  2. Clinical classification in low back pain: best-evidence diagnostic rules based on systematic reviews.

    Science.gov (United States)

    Petersen, Tom; Laslett, Mark; Juhl, Carsten

    2017-05-12

    Clinical examination findings are used in primary care to give an initial diagnosis to patients with low back pain and related leg symptoms. The purpose of this study was to develop best evidence Clinical Diagnostic Rules (CDR] for the identification of the most common patho-anatomical disorders in the lumbar spine; i.e. intervertebral discs, sacroiliac joints, facet joints, bone, muscles, nerve roots, muscles, peripheral nerve tissue, and central nervous system sensitization. A sensitive electronic search strategy using MEDLINE, EMBASE and CINAHL databases was combined with hand searching and citation tracking to identify eligible studies. Criteria for inclusion were: persons with low back pain with or without related leg symptoms, history or physical examination findings suitable for use in primary care, comparison with acceptable reference standards, and statistical reporting permitting calculation of diagnostic value. Quality assessments were made independently by two reviewers using the Quality Assessment of Diagnostic Accuracy Studies tool. Clinical examination findings that were investigated by at least two studies were included and results that met our predefined threshold of positive likelihood ratio ≥ 2 or negative likelihood ratio ≤ 0.5 were considered for the CDR. Sixty-four studies satisfied our eligible criteria. We were able to construct promising CDRs for symptomatic intervertebral disc, sacroiliac joint, spondylolisthesis, disc herniation with nerve root involvement, and spinal stenosis. Single clinical test appear not to be as useful as clusters of tests that are more closely in line with clinical decision making. This is the first comprehensive systematic review of diagnostic accuracy studies that evaluate clinical examination findings for their ability to identify the most common patho-anatomical disorders in the lumbar spine. In some diagnostic categories we have sufficient evidence to recommend a CDR. In others, we have only

  3. A new condition for assessing the clinical efficiency of a diagnostic test.

    Science.gov (United States)

    Bokhari, Ehsan; Hubert, Lawrence

    2015-09-01

    When prediction using a diagnostic test outperforms simple prediction using base rates, the test is said to be "clinically efficient," a term first introduced into the literature by Meehl and Rosen (1955) in Psychological Bulletin. This article provides three equivalent conditions for determining the clinical efficiency of a diagnostic test: (a) Meehl-Rosen (Meehl & Rosen, 1955); (b) Dawes (Dawes, 1962); and (c) the Bokhari-Hubert condition, introduced here for the first time. Clinical efficiency is then generalized to situations where misclassification costs are considered unequal (for example, false negatives are more costly than false positives). As an illustration, the clinical efficiency of an actuarial device for predicting violent and dangerous behavior is examined that was developed as part of the MacArthur Violence Risk Assessment Study. (c) 2015 APA, all rights reserved.

  4. Effect of clinical specialist physiotherapists in orthopaedic diagnostic setting - A systematic review

    DEFF Research Database (Denmark)

    Trøstrup, Jeanette; Mikkelsen, Lone Ramer; Juhl, Carsten

    with advanced clinical competencies; Clinical Specialist Physiotherapists (CSP). The use of CSPs instead of OSs to perform diagnostic assessment of patients with musculoskeletal complaints has been implemented in several countries (1). Earlier systematic reviews have evaluated CSPs effectiveness in diagnosing...... methodological quality where one study of high methodological quality found that CSP-clinics were more expensive than OS-led clinics. Patient satisfaction (n=12) ranged from 77–100 % being satisfied (n=9) with similar satisfaction in studies of low, acceptable and high methodological quality. In three studies...

  5. Clinical applications of resting state functional connectivity

    Directory of Open Access Journals (Sweden)

    Michael D Fox

    2010-06-01

    Full Text Available During resting conditions the brain remains functionally and metabolically active. One manifestation of this activity that has become an important research tool is spontaneous fluctuations in the blood oxygen level dependent (BOLD signal of fMRI. The identification of correlation patterns in these spontaneous fluctuations has been termed resting state functional connectivity (fcMRI and has the potential to greatly increase the translation of fMRI into clinical care. In this article we review the advantages of the resting state signal for clinical applications including detailed discussion of signal to noise considerations. We include guidelines for performing resting state research on clinical populations, outline the different areas for clinical application, and identify important barriers to be addressed to facilitate the translation of resting state fcMRI into the clinical realm.

  6. Outbreak!: Teaching Clinical and Diagnostic Microbiology Methodologies with an Interactive Online Game

    Science.gov (United States)

    Clark, Sherri; Smith, Geoffrey Battle

    2004-01-01

    Outbreak! is an online, interactive educational game that helps students and teachers learn and evaluate clinical microbiology skills. When the game was used in introductory microbiology laboratories, qualitative evaluation by students showed very positive responses and increased learning. Outbreak! allows students to design diagnostic tests and…

  7. Diagnostic investigation of patients with chronic polyneuropathy: evaluation of a clinical guideline

    NARCIS (Netherlands)

    Rosenberg, N. R.; Portegies, P.; de Visser, M.; Vermeulen, M.

    2001-01-01

    OBJECTIVE: (1) To evaluate a clinical guideline for the diagnostic investigation of patients presenting with signs and symptoms (present for longer than 6 weeks) suggesting a chronic polyneuropathy. (2) To investigate the contribution of electrophysiological studies to a focused search for aetiology

  8. Clinical applications of selected binaural effects.

    Science.gov (United States)

    Noffsinger, D

    1982-01-01

    Examination was made of the behaviors exhibited on selected binaural tasks by 556 persons with diagnosed peripheral hearing loss or central nervous system damage. The tasks used included loudness balancing (LB), intracranial midline imaging (MI), masking level differences (MLD), and binaural beats (BB). The methods used were chosen for their clinical utility. Loudness balancing and midline imaging were of the most diagnostic value when hearing loss was present. Masking level differences were best at detecting pathology which did not produce hearing loss. None of the techniques were sensitive to cortical damage.

  9. APPLICATION OF MRI IN THE DIAGNOSTICS OF M. MASSETER

    Directory of Open Access Journals (Sweden)

    Mariana Dimova-Gabrovska

    2017-06-01

    Full Text Available Magnetic resonance imaging (MRI is a non-invasive diagnostic method which can provide detailed images of organs and structures of the human body. The purpose of this review is to explore and introduce the diagnostic capabilities of MRI in imaging m. masseter in conditions of norm and pathology. The material of the review is information of 20 literary sources selected from 530, found by keywordsfromJanuary to April 2017. The information about MRI imaging of the normal anatomy of m. masseter and the most common findings in muscle - muscle hypertrophy, inflammatory changes, vascular malformations, intramuscular hemangioma, cysticercosis and changes after radiotherapy was analyzed. In conclusion, the diagnostic capabilities of MRI of masseter muscle – both in the conditions of norm and pathology were confirmed. The method is considered to be reliable, objective, non-invasive and accurate.

  10. Elimination of pain improves specificity of clinical diagnostic criteria for adult chronic rhinosinusitis.

    Science.gov (United States)

    Hirsch, Scott D; Reiter, Evan R; DiNardo, Laurence J; Wan, Wen; Schuman, Theodore A

    2017-05-01

    Determine whether the elimination of pain improves accuracy of clinical diagnostic criteria for adult chronic rhinosinusitis. Retrospective cohort study. History, symptoms, nasal endoscopy, and computed tomography (CT) results were analyzed for 1,186 adults referred to an academic otolaryngology clinic with presumptive diagnosis of chronic rhinosinusitis. Clinical diagnosis was rendered using the 1997 Rhinosinusitis Taskforce (RSTF) Guidelines and a modified version eliminating facial pain, ear pain, dental pain, and headache. Four hundred seventy-nine subjects (40%) met inclusion criteria. Among subjects positive by RSTF guidelines, 45% lacked objective evidence of sinonasal inflammation by CT, 48% by endoscopy, and 34% by either modality. Applying modified RSTF diagnostic criteria, 39% lacked sinonasal inflammation by CT, 38% by endoscopy, and 24% by either modality. Using either abnormal CT or endoscopy as the reference standard, modified diagnostic criteria yielded a statistically significant increase in specificity from 37.1% to 65.1%, with a nonsignificant decrease in sensitivity from 79.2% to 70.3%. Analysis of comorbidities revealed temporomandibular joint disorder, chronic cervical pain, depression/anxiety, and psychiatric medication use to be negatively associated with objective inflammation on CT or endoscopy. Clinical diagnostic criteria overestimate the prevalence of chronic rhinosinusitis. Removing facial pain, ear pain, dental pain, and headache increased specificity without a concordant loss in sensitivity. Given the high prevalence of sinusitis, improved clinical diagnostic criteria may assist primary care providers in more accurately predicting the presence of inflammation, thereby reducing inappropriate antibiotic use or delayed referral for evaluation of primary headache syndromes. 4. Laryngoscope, 127:1011-1016, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  11. Impact of molecular imaging on the diagnostic process in a memory clinic.

    Science.gov (United States)

    Ossenkoppele, Rik; Prins, Niels D; Pijnenburg, Yolande A L; Lemstra, Afina W; van der Flier, Wiesje M; Adriaanse, Sofie F; Windhorst, Albert D; Handels, Ron L H; Wolfs, Claire A G; Aalten, Pauline; Verhey, Frans R J; Verbeek, Marcel M; van Buchem, Mark A; Hoekstra, Otto S; Lammertsma, Adriaan A; Scheltens, Philip; van Berckel, Bart N M

    2013-07-01

    [(11)C]Pittsburgh compound B ([(11)C]PIB) and [(18)F]-2-fluoro-2-deoxy-D-glucose ([(18)F]FDG) PET measure fibrillar amyloid-β load and glucose metabolism, respectively. We evaluated the impact of these tracers on the diagnostic process in a memory clinic population. One hundred fifty-four patients underwent paired dynamic [(11)C]PIB and static [(18)F]FDG PET scans shortly after completing a standard dementia screening. Two-year clinical follow-up data were available for 39 patients. Parametric PET images were assessed visually and results were reported to the neurologists responsible for the initial diagnosis. Outcome measures were (change in) clinical diagnosis and confidence in that diagnosis before and after disclosing PET results. [(11)C]PIB scans were positive in 40 of 66 (61%) patients with a clinical diagnosis of Alzheimer's disease (AD), 5 of 18 (28%) patients with frontotemporal dementia (FTD), 4 of 5 (80%) patients with Lewy body dementia, and 3 of 10 (30%) patients with other dementias. [(18)F]FDG uptake patterns matched the clinical diagnosis in 38 of 66 (58%) of AD patients, and in 6 of 18 (33%) FTD patients. PET results led to a change in diagnosis in 35 (23%) patients. This only occurred when prior diagnostic certainty was Diagnostic confidence increased from 71 ± 17% before to 87 ± 16% after PET (p diagnostic work-up, especially when prior diagnostic confidence is low. Copyright © 2013 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  12. 7T: Physics, safety, and potential clinical applications.

    Science.gov (United States)

    Kraff, Oliver; Quick, Harald H

    2017-12-01

    With more than 60 installed magnetic resonance imaging (MRI) systems worldwide operating at a magnetic field strength of 7T or higher, ultrahigh-field (UHF) MRI has been established as a platform for clinically oriented research in recent years. Profound technical and methodological developments have helped overcome the inherent physical challenges of UHF radiofrequency (RF) signal homogenization in the human body. The ongoing development of dedicated RF coil arrays was pivotal in realizing UHF body MRI, beyond mere brain imaging applications. Another precondition to clinical application of 7T MRI is the safety testing of implants and the establishment of safety concepts. Against this backdrop, 7T MRI and MR spectroscopy (MRS) recently have demonstrated capabilities and potentials for clinical diagnostics in a variety of studies. This article provides an overview of the immanent physical challenges of 7T UHF MRI and discusses recent technical solutions and safety concepts. Furthermore, recent clinically oriented studies are highlighted that span a broad application spectrum from 7T UHF brain to body MRI. 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1573-1589. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Diagnostic Approaches to Sjögren’s Syndrome: a Literature Review and Own Clinical Experience

    Directory of Open Access Journals (Sweden)

    Pedro de Sousa Gomes

    2012-03-01

    Full Text Available Objectives: The purpose of present paper is to critically address the recent advances on diagnostic procedures of Sjögren’s syndrome, taking into account the attained local and systemic features of the disease. Material and Methods: A comprehensive review of the available literature regarding to the diagnostic approaches to Sjögren’s syndrome was conducted. Eligible studies were identified by searching the electronic literature PubMed, Medline, Embase, and ScienceDirect databases for relevant reports (last search update January 2012 combining the MESH heading term “Sjögren’s syndrome”, with the words "diagnosis, diagnostic procedures, salivary gland function, ocular tests, histopathology, salivary gland imaging, serology". The authors checked the references of the selected articles to identify additional eligible publications and contacted the authors, if necessary. Results: Presented article addresses the established diagnostic criteria for Sjögren’s syndrome and critically evaluates the most commonly used diagnostic procedures, presenting data from author’s own clinical experience. Diagnostic criteria for Sjögren’s syndrome are required both by healthcare professionals and patients, namely in order to provide a rational basis for the assessment of the symptoms, establish an individual disease prognosis, and orientate the therapeutic intervention. Conclusions: Sjögren’s syndrome is quite a common autoimmune disease of which the diagnosis and treatment are not easily established. Due to its systemic involvement, it can exhibit a wide range of clinical manifestations that contribute to confusion and delay in diagnosis. The use of proper diagnostic modalities will help to reduce the time to diagnosis and preserve the health and quality of life of patients with Sjögren’s syndrome.

  14. New technology for ultrasensitive detection and isolation of rare cells for clinical diagnostics and therapeutics

    Science.gov (United States)

    Leary, James F.; McLaughlin, Scott R.

    1995-04-01

    A high-speed, 11-parameter, 6-color fluorescence, laser flow cytometer/cell sorter with a number of special and unique features has been built for ultrasensitive detection and isolation of rare cells for clinical diagnostics and therapeutics. The software for real-time data acquisition and sort control, written as C++ programming language modules with a WindowsTM graphical user interface, runs on a 66-MHz 80486 computer joined by an extended bus to 23 sophisticated multi-layered boards of special data acquisition and sorting electronics. Special features include: high-speed (> 100,000 cells/sec) real-time data classification module (U.S. Patent 5,204,884 (1993)); real-time principal component cell sorting; multi-queue signal-processing system with multiple hardware and software event buffers to reduce instrument dead time, LUT charge-pulse definition, high-resolution `flexible' sorting for optimal yield/purity sort strategies (U.S. Patent 5,199,576); pre-focusing optical wavelength correction for a second laser beam; and two trains of three fluorescence detectors-- each adjustable for spatial separation to interrogate only one of two laser beams, syringe- driven or pressure-driven fluidics, and time-windowed parameters. The system has been built to be both expandable and versatile through the use of LUT's and a modular hardware and software design. The instrument is especially useful at detection and isolation of rare cell subpopulations for which our laboratory is well-known. Cell subpopulations at frequencies as small as 10-7 have been successfully studied with this system. Current applications in clinical diagnostics and therapeutics include detection and isolation of (1) fetal cells from material blood for prenatal diagnosis of birth defects, (2) hematopoietic stem and precursor cells for autologous bone marrow transplantation, (3) metastatic breast cancer cells for molecular characterization, and (4) HIV-infected maternal cells in newborn blood to study mother

  15. Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-08-15

    This publication presents a harmonized approach to quality assurance in the field of computed tomography applied to both diagnostics and therapy. It gives a careful analysis of the principles and specific instructions that can be used for a quality assurance programme for optimal performance and reduced patient dose in diagnostic radiology. In some cases, radiotherapy programmes are making a transition from 2-D to 3-D radiotherapy, a complex process which critically depends on accurate treatment planning. In this respect, the authors also provide detailed information about the elements needed for quality assurance testing, including those relating to accurate patient characterization as needed for radiotherapy treatment planning.

  16. New possibilities of complex "Thermodyn" application for contactless remote diagnostics in medical practice

    Science.gov (United States)

    Belov, M. Ye.; Shayko-Shaykovskiy, O. G.; Makhrova, Ye. G.; Kramar, V. M.; Oleksuik, I. S.

    2018-01-01

    We represent here the theoretical justifications, block scheme and experimental sample of a new automated complex "Thermodyn" for remote contactless diagnostics of inflammatory processes of the surfaces and in subcutaneous areas of human body. Also we described here the methods and results of diagnostic measurements, and results of practical applications of this complex.

  17. fMRI. Basics and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Ulmer, Stephan; Jansen, Olav (eds.) [University Hospital of Schleswig-Holstein, Kiel (Germany). Inst. of Neuroradiology, Neurocenter

    2010-07-01

    Functional MRI (fMRI) and the basic method of BOLD imaging were introduced in 1993 by Seiji Ogawa. From very basic experiments, fMRI has evolved into a clinical application for daily routine brain imaging. There have been various improvements in both the imaging technique as such as well as in the statistical analysis. In this volume, experts in the field share their knowledge and point out possible technical barriers and problems explaining how to solve them. Starting from the very basics on the origin of the BOLD signal, the book covers technical issues, anatomical landmarks, presurgical applications, and special issues in various clinical fields. Other modalities for brain mapping such as PET, TMS, and MEG are also compared with fMRI. This book is intended to give a state-of-the-art overview and to serve as a reference and guide for clinical applications of fMRI. (orig.)

  18. A Robust Automated Cataract Detection Algorithm Using Diagnostic Opinion Based Parameter Thresholding for Telemedicine Application

    Directory of Open Access Journals (Sweden)

    Shashwat Pathak

    2016-09-01

    Full Text Available This paper proposes and evaluates an algorithm to automatically detect the cataracts from color images in adult human subjects. Currently, methods available for cataract detection are based on the use of either fundus camera or Digital Single-Lens Reflex (DSLR camera; both are very expensive. The main motive behind this work is to develop an inexpensive, robust and convenient algorithm which in conjugation with suitable devices will be able to diagnose the presence of cataract from the true color images of an eye. An algorithm is proposed for cataract screening based on texture features: uniformity, intensity and standard deviation. These features are first computed and mapped with diagnostic opinion by the eye expert to define the basic threshold of screening system and later tested on real subjects in an eye clinic. Finally, a tele-ophthamology model using our proposed system has been suggested, which confirms the telemedicine application of the proposed system.

  19. Feasibility of streamlining an interactive Bayesian-based diagnostic support tool designed for clinical practice

    Science.gov (United States)

    Chen, Po-Hao; Botzolakis, Emmanuel; Mohan, Suyash; Bryan, R. N.; Cook, Tessa

    2016-03-01

    In radiology, diagnostic errors occur either through the failure of detection or incorrect interpretation. Errors are estimated to occur in 30-35% of all exams and contribute to 40-54% of medical malpractice litigations. In this work, we focus on reducing incorrect interpretation of known imaging features. Existing literature categorizes cognitive bias leading a radiologist to an incorrect diagnosis despite having correctly recognized the abnormal imaging features: anchoring bias, framing effect, availability bias, and premature closure. Computational methods make a unique contribution, as they do not exhibit the same cognitive biases as a human. Bayesian networks formalize the diagnostic process. They modify pre-test diagnostic probabilities using clinical and imaging features, arriving at a post-test probability for each possible diagnosis. To translate Bayesian networks to clinical practice, we implemented an entirely web-based open-source software tool. In this tool, the radiologist first selects a network of choice (e.g. basal ganglia). Then, large, clearly labeled buttons displaying salient imaging features are displayed on the screen serving both as a checklist and for input. As the radiologist inputs the value of an extracted imaging feature, the conditional probabilities of each possible diagnosis are updated. The software presents its level of diagnostic discrimination using a Pareto distribution chart, updated with each additional imaging feature. Active collaboration with the clinical radiologist is a feasible approach to software design and leads to design decisions closely coupling the complex mathematics of conditional probability in Bayesian networks with practice.

  20. System for simulating fluctuation diagnostics for application to turbulence computations

    International Nuclear Information System (INIS)

    Bravenec, R.V.; Nevins, W.M.

    2006-01-01

    Present-day nonlinear microstability codes are able to compute the saturated fluctuations of a turbulent fluid versus space and time, whether the fluid be liquid, gas, or plasma. They are therefore able to determine turbulence-induced fluid (or particle) and energy fluxes. These codes, however, must be tested against experimental data not only with respect to transport but also characteristics of the fluctuations. The latter is challenging because of limitations in the diagnostics (e.g., finite spatial resolution) and the fact that the diagnostics typically do not measure exactly the quantities that the codes compute. In this work, we present a system based on IDL registered analysis and visualization software in which user-supplied 'diagnostic filters' are applied to the code outputs to generate simulated diagnostic signals. The same analysis techniques as applied to the measurements, e.g., digital time-series analysis, may then be applied to the synthesized signals. Their statistical properties, such as rms fluctuation level, mean wave numbers, phase and group velocities, correlation lengths and times, and in some cases full S(k,ω) spectra, can then be compared directly to those of the measurements

  1. Application of statistical process control to qualitative molecular diagnostic assays.

    Directory of Open Access Journals (Sweden)

    Cathal P O'brien

    2014-11-01

    Full Text Available Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control. Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply statistical process control to assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater samples with a resultant protracted time to detection. Modelled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of statistical process control to qualitative laboratory data.

  2. The Hampstead Clinic at work. Discussions in the Diagnostic Profile Research Group.

    Science.gov (United States)

    Koch, Ehud

    2012-01-01

    Minutes of the Hampstead Clinic's Diagnostic Profile Research Group during a fifteen-month period (1964-1965) are reviewed and discussed. A wide range of topics were considered and discussed, with a special focus on the affective life, object relations, and ego function of atypical children in comparison to the early ego functions and differentiation of normal and neurotic children. These lively clinical and theoretical discussions and their implications for therapeutic work with a wide range of children, demonstrate the multifaceted leadership and contributions of Anna Freud as teacher, clinician, and thinker, and of the Hampstead Clinic as a major center for psychoanalytic studies.

  3. Precision diagnostics: moving towards protein biomarker signatures of clinical utility in cancer.

    Science.gov (United States)

    Borrebaeck, Carl A K

    2017-03-01

    Interest in precision diagnostics has been fuelled by the concept that early detection of cancer would benefit patients; that is, if detected early, more tumours should be resectable and treatment more efficacious. Serum contains massive amounts of potentially diagnostic information, and affinity proteomics has risen as an accurate approach to decipher this, to generate actionable information that should result in more precise and evidence-based options to manage cancer. To achieve this, we need to move from single to multiplex biomarkers, a so-called signature, that can provide significantly increased diagnostic accuracy. This Opinion article focuses on the progress being made in identifying protein biomarker signatures of clinical utility, using blood-based proteomics.

  4. [Applications of MALDI-TOF technology in clinical microbiology].

    Science.gov (United States)

    Suarez, S; Nassif, X; Ferroni, A

    2015-02-01

    Until now, the identification of micro-organisms has been based on the cultural and biochemical characteristics of bacterial and fungal species. Recently, Mass Spectrometry type Matrix-Assisted Laser Desorption Ionization-Time of Flight (MALDI-TOF MS) was developed in clinical microbiology laboratories. This new technology allows identification of micro-organisms directly from colonies of bacteria and fungi within few minutes. In addition, it can be used to identify germs directly from positive blood culture bottles or directly from urine samples. Other ways are being explored to expand the use of MALDI-TOF in clinical microbiology laboratories. Indeed, some studies propose to detect bacterial antibiotic resistance while others compare strains within species for faster strain typing. The main objective of this review is to update data from the recent literature for different applications of MALDI-TOF technique in microbiological diagnostic routine. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  5. A clinical audit programme for diagnostic radiology: The Approach adopted by the international atomic energy agency

    International Nuclear Information System (INIS)

    Faulkner, K.; Jaervinen, H.; Butler, P.; McLean, I. D.; Pentecost, M.; Rickard, M.; Abdullah, B.

    2010-01-01

    The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to

  6. DIAGNOSTIC ACCURACY OF CLINICAL AND MAGNETIC RESONANCE IN KNEE MENISCI AND LIGAMENTOUS INJURIES

    Directory of Open Access Journals (Sweden)

    Nilesh

    2016-03-01

    Full Text Available OBJECTIVE The purpose of this study was to evaluate the reliability of clinical diagnosis compared to MRI findings in ligamentous and meniscal injuries with respect to arthroscopic confirmation as a gold standard. METHODS 485 patients with knee injuries were prospectively assessed by clinical evaluation and magnetic resonance imaging and correlated after therapeutic arthroscopy. The overall accuracy, clinically productive values of sensitivity and specificity was derived. The actual value of the test with respect to positive predictive and negative predictive value was also derived, taking arthroscopic findings as confirmatory. The overall partial and total agreement among the clinical, MRI and arthroscopy was documented. RESULTS The overall accuracy for clinical examination was 85, 92, 100 and 100 and accuracy for MRI was 90, 97, 97 and 97 for detecting medial meniscus, lateral meniscus, ACL and PCL tears respectively. Clinically lateral meniscus tears are difficult to diagnose clinically with negative predictive value (90 whereas ACL injuries do not need MRI for diagnosis as evident by a high negative predictive value (100 of clinical examination. Total agreement with the clinical findings confirmed by arthroscopy was 64.40% which was relatively high as compared to total agreement of MRI findings which was only 31.50%. We found similar total agreement versus total disagreement of both clinical and MRI to be only 2.74% indicating very high accuracy in clinical diagnosis of meniscal and ligamentous injuries combined. CONCLUSION The clinical evaluation alone is sufficient to diagnose meniscal and ACL/PCL pathologies and MRI should be considered only as a powerful negative diagnostic tool. The arthroscopy decision should not be heavily dependent on MRI for ligamentous injuries but reverse is true for meniscal lesions. MR evaluation functions as a powerful negative diagnostic tool to rule out doubtful and complex knee injuries.

  7. A clinical audit programme for diagnostic radiology: the approach adopted by the International Atomic Energy Agency.

    Science.gov (United States)

    Faulkner, K; Järvinen, H; Butler, P; McLean, I D; Pentecost, M; Rickard, M; Abdullah, B

    2010-01-01

    The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to

  8. Searching for neurodegeneration in multiple sclerosis at clinical onset: Diagnostic value of biomarkers.

    Science.gov (United States)

    Novakova, Lenka; Axelsson, Markus; Malmeström, Clas; Imberg, Henrik; Elias, Olle; Zetterberg, Henrik; Nerman, Olle; Lycke, Jan

    2018-01-01

    Neurodegeneration occurs during the early stages of multiple sclerosis. It is an essential, devastating part of the pathophysiology. Tools for measuring the degree of neurodegeneration could improve diagnostics and patient characterization. This study aimed to determine the diagnostic value of biomarkers of degeneration in patients with recent clinical onset of suspected multiple sclerosis, and to evaluate these biomarkers for characterizing disease course. This cross-sectional study included 271 patients with clinical features of suspected multiple sclerosis onset and was the baseline of a prospective study. After diagnostic investigations, the patients were classified into the following disease groups: patients with clinically isolated syndrome (n = 4) or early relapsing remitting multiple sclerosis (early RRMS; n = 93); patients with relapsing remitting multiple sclerosis with disease durations ≥2 years (established RRMS; n = 39); patients without multiple sclerosis, but showing symptoms (symptomatic controls; n = 89); and patients diagnosed with other diseases (n = 46). In addition, we included healthy controls (n = 51) and patients with progressive multiple sclerosis (n = 23). We analyzed six biomarkers of neurodegeneration: cerebrospinal fluid neurofilament light chain levels; cerebral spinal fluid glial fibrillary acidic protein; cerebral spinal fluid tau; retinal nerve fiber layer thickness; macula volume; and the brain parenchymal fraction. Except for increased cerebral spinal fluid neurofilament light chain levels, median 670 ng/L (IQR 400-2110), we could not find signs of early degeneration in the early disease group with recent clinical onset. However, the intrathecal immunoglobin G production and cerebral spinal fluid neurofilament light chain levels showed diagnostic value. Moreover, elevated levels of cerebral spinal fluid glial fibrillary acidic protein, thin retinal nerve fiber layers, and low brain parenchymal fractions were associated with

  9. Clinical Applications of Transcranial Magnetic Stimulation in Pediatric Neurology.

    Science.gov (United States)

    Narayana, Shalini; Papanicolaou, Andrew C; McGregor, Amy; Boop, Frederick A; Wheless, James W

    2015-08-01

    Noninvasive brain stimulation is now an accepted technique that is used as a diagnostic aid and in the treatment of neuropsychiatric disorders in adults, and is being increasingly used in children. In this review, we will discuss the basic principles and safety of one noninvasive brain stimulation method, transcranial magnetic stimulation. Improvements in the spatial accuracy of transcranial magnetic stimulation are described in the context of image-guided transcranial magnetic stimulation. The article describes and provides examples of the current clinical applications of transcranial magnetic stimulation in children as an aid in the diagnosis and treatment of neuropsychiatric disorders and discusses future potential applications. Transcranial magnetic stimulation is a noninvasive tool that is safe for use in children and adolescents for functional mapping and treatment, and for many children it aids in the preoperative evaluation and the risk-benefit decision making. © The Author(s) 2014.

  10. The diagnostic application of radiocolloid liver scintigraphy in breast carcinoma

    International Nuclear Information System (INIS)

    Galli, G.; Maini, C.L.; Salvatori, M.; Cefaro, G.A.

    1982-01-01

    The authors have reviewed their experiences in determining the presence of liver metastases in 103 patients by radiocolloid scanning. The sensitivity of liver scanning proved to be quite low if the presence of focal defects in the distribution of the tracer was chosen as the diagnostic criterion. The inclusion of less restrictive criteria such as liver enlargement or irregular distribution of the tracer, resulted in a higher sensitivity without lowering the predictive value of a negative scan. Using the latter diagnostic criterion, sensitivity, specificity and accuracy were in the range of 90%. Abnormal liver scans are common in patients classified as T3-T4 or N+ and their chances of being 'true positive' are high. Conversely, abnormal scans are seldom found in patients classified as T1-T2 or N 0 and probabilities of 'false positive' results are high. (orig.) [de

  11. Diagnostic outcome following routine genetics clinic referral for the assessment of global developmental delay.

    LENUS (Irish Health Repository)

    Shahdadpuri, R

    2012-02-01

    The aim of this study was to ascertain the diagnostic yield following a routine genetics clinic referral for the assessment of global developmental delay. Detailed retrospective review of 119 complete consecutive case notes of patients referred to one single clinical geneticist over a 14 month time period was undertaken (n = 119; 54 males, 65 females). The age at initial review ranged from 2 months to 37 years 3 months (mean 8 y 3 mo [SD 7 y 10 mo]). We made a diagnosis in 36\\/119 (30%); 21\\/36 were new diagnoses and 15\\/36 were confirmations of diagnoses. We removed a wrong diagnostic label in 8\\/119 (7%). In 3\\/8 we were able to achieve a diagnosis but in 5\\/8 no alternative diagnosis was reached. We had a better diagnostic rate where the patients were dysmorphic (odds ratio [OR] 1.825; 95% confidence interval [CI] 1.065 to 3.128, p = 0.044). In the majority, the diagnosis was made by clinical examination only. Molecular diagnosis was reached in seven cases. Five cases were confirmed by cytogenetic analysis. Brain magnetic resonance imaging (MRI) revealed a diagnosis in three cases. This study confirms the importance of a clinical genetics assessment in the investigation of global developmental delay.

  12. The application of nanotechnology in medicine: treatment and diagnostics.

    Science.gov (United States)

    Owen, Andrew; Dufès, Christine; Moscatelli, Davide; Mayes, Eric; Lovell, Jonathan F; Katti, Kattesh V; Sokolov, Konstantin; Mazza, Mariarosa; Fontaine, Olivier; Rannard, Steve; Stone, Vicki

    2014-07-01

    Nanomedicine 2014 Edinburgh, UK, 26-27 March 2014 The British Society for Nanomedicine (BSNM), in collaboration with SELECTBIO, organized Nanomedicine 2014. BSNM is a registered charity created to allow open access for industry, academia, clinicians and the public to news and details of ongoing nanomedicine research. The Nanomedicine 2014 program provided insight across a number of emerging nanotechnologies spanning treatment to diagnostics. A key objective of the meeting was provision of opportunities to build collaborations and rationalize nanoenabled healthcare solutions.

  13. INTEGRATED APPLICATION OF OPTICAL DIAGNOSTIC METHODS IN ULCERATIVE COLITIS

    Directory of Open Access Journals (Sweden)

    E. V. Velikanov

    2013-01-01

    Full Text Available Abstract. Our results suggest that the combined use of optical coherent tomography (OCT and fluorescence diagnosis helps to refine the nature and boundaries of the pathological process in the tissue of the colon in ulcerative colitis. Studies have shown that an integrated optical diagnostics allows us to differentiate lesions respectively to histology and to decide on the need for biopsy and venue. This method is most appropriate in cases difficult for diagnosis. 

  14. Application of the new International Code of Practice for dosimetry in diagnostic radiology to conventional exams

    International Nuclear Information System (INIS)

    Martinez Gonzalez, A.; Cardenas Herrera, J.; Walwyn Salas, G.; Machado, A.; Mora Machado, R. de la

    2008-01-01

    Full text: During the recent years, a policy for updating and installation of the X-ray equipment, specialized as well as conventional, have been carrying out, in Cuba. Conventional equipment has reached almost the whole primary level. Considering this situation, the quality control programs and clinical dosimetry have become even more important. Regarding the last one, an International Code of Practice for Dosimetry in Diagnostic Radiology had been published by the International Atomic Energy Agency in order to been used as a guide and to standardize the methodologies used to evaluate the patient exposure in radiodiagnostic. Taken into consideration the above reasons, an assessment of the aforementioned code of practice was done in order to choose the most feasible methodology to implement in the country. The evaluation was performed considering the lack of dosimetric equipment and medical physicists in this practice, in the interests of increasing the measurements scope to a large number of services as well as to standardize the methodology on a national scale. The present work shows the results obtained from the application of the new code of practice to conventional radiology exams in some medical institutions. Out of 3 on patients measurements methodologies described in the code of practice, the one of measurement of the incident air kerma was chosen. This methodology allow to the physicist to focus on the diagnostic equipment tests and to delegate the collection of the patient and exposure parameters data to the technicians, which make the increased of the patient and diagnostic departments sample, possible. The measurements were carried out in 2 hospital of the capital. The exams involved in the assessments were thorax PA, lumbar spine AP and lumbar spine LAT. In every diagnostic service, 25 patients were chosen on each projection. The weight and height average of the patient sample were 68 kg and 167 cm respectively. In the assessment were considered only

  15. Diagnostic Validity of Clinical Signs Associated with a Large Exophoria at Near

    Directory of Open Access Journals (Sweden)

    Pilar Cacho-Martínez

    2013-01-01

    Full Text Available Purpose. To analyze the diagnostic validity of accommodative and binocular tests in a sample of patients with a large near exophoria with moderate to severe symptoms. Methods. Two groups of patients between 19 and 35 years were recruited from a university clinic: 33 subjects with large exophoria at near vision and moderate or high visual discomfort and 33 patients with normal heterophoria and low visual discomfort. Visual discomfort was defined using the Conlon survey. A refractive exam and an exhaustive evaluation of accommodation and vergence were assessed. Diagnostic validity by means of receiver operator characteristic (ROC curves, sensitivity (S, specificity (Sp, and positive and negative likelihood ratios (LR+, LR− were assessed. This analysis was also carried out considering multiple tests as serial testing strategy. Results. ROC analysis showed the best diagnostic accuracy for receded near point of convergence (NPC recovery (area = 0.929 and binocular accommodative facility (BAF (area = 0.886. Using the cut-offs obtained with ROC analysis, the best diagnostic validity was obtained for the combination of NPC recovery and BAF (S  =  0.77, Sp = 1, LR+ = value tending to infinity, LR− = 0.23 and the combination of NPC break and recovery with BAF (S  =  0.73, Sp = 1, LR+ = tending to infinity, LR− = 0.27. Conclusions. NPC and BAF tests were the tests with the best diagnostic accuracy for subjects with large near exophoria and moderate to severe symptoms.

  16. The relevance of 'mixed anxiety and depression' as a diagnostic category in clinical practice.

    Science.gov (United States)

    Möller, Hans-Jürgen; Bandelow, Borwin; Volz, Hans-Peter; Barnikol, Utako Birgit; Seifritz, Erich; Kasper, Siegfried

    2016-12-01

    According to ICD-10 criteria, mixed anxiety and depressive disorder (MADD) is characterized by co-occurring, subsyndromal symptoms of anxiety and depression, severe enough to justify a psychiatric diagnosis, but neither of which are clearly predominant. MADD appears to be very common, particularly in primary care, although prevalence estimates vary, often depending on the diagnostic criteria applied. It has been associated with similarly pronounced distress, impairment of daily living skills, and reduced health-related quality of life as fully syndromal depression and anxiety. Although about half of the patients affected remit within a year, non-remitting patients are at a high risk of transition to a fully syndromal psychiatric disorder. The validity and clinical usefulness of MADD as a diagnostic category are under debate. It has not been included in the recently released DSM-5 since the proposed diagnostic criteria turned out to be not sufficiently reliable. Moreover, reviewers have disputed the justification of MADD based on divergent results regarding its prevalence and course, diagnostic stability over time, and nosological inconsistencies between subthreshold and threshold presentations of anxiety and depressive disorders. We review the evidence in favor and against MADD and argue that it should be included into classification systems as a diagnostic category because it may enable patients to gain access to appropriate treatment early. This may help to reduce patients' distress, prevent exacerbation to a more serious psychiatric disorder, and ultimately reduce the societal costs of this very common condition.

  17. The clinical applicability of music therapy research

    DEFF Research Database (Denmark)

    Wigram, Anthony Lewis

    in lengthy and complex theses is seldom accessible to the practitioner working ‘at the coal-face’; and sometimes lacks clear direction on how the results are applicable in everyday therapy. For results to be implemented in clinical practice and disseminated to colleagues in related fields as well as senior...

  18. Comprehensive Clinical Audits of Diagnostic Radiology Practices: A Tool for Quality Improvement. Quality Assurance Audit for Diagnostic Radiology Improvement and Learning (QUAADRIL)

    International Nuclear Information System (INIS)

    2011-01-01

    Interest in quality assurance processes and quality improvement in diagnostic radiology is being driven by a number of factors. These include the high cost and complexity of radiological equipment, acknowledgement of the possibility of increasing doses to patients, and the importance of radiological diagnosis to patient management within the health care environment. To acknowledge these interests, clinical audits have been introduced and, in Europe, mandated under a European Directive (Council Directive 97/47/EURATOM). Comprehensive clinical audits focus on clinical management and infrastructure, patient related and technical procedures, and education and research. This publication includes a structured set of standards appropriate for diagnostic radiology, an audit guide to their clinical review, and data collection sheets for the rapid production of reports in audit situations. It will be a useful guide for diagnostic radiology facilities wishing to improve their service to patients through timely diagnosis with minimal radiation dose.

  19. Comprehensive Clinical Audits of Diagnostic Radiology Practices: A Tool for Quality Improvement. Quality Assurance Audit for Diagnostic Radiology Improvement and Learning (QUAADRIL)

    International Nuclear Information System (INIS)

    2010-01-01

    Interest in quality assurance processes and quality improvement in diagnostic radiology is being driven by a number of factors. These include the high cost and complexity of radiological equipment, acknowledgement of the possibility of increasing doses to patients, and the importance of radiological diagnosis to patient management within the health care environment. To acknowledge these interests, clinical audits have been introduced and, in Europe, mandated under a European Directive (Council Directive 97/47/EURATOM). Comprehensive clinical audits focus on clinical management and infrastructure, patient related and technical procedures, and education and research. This publication includes a structured set of standards appropriate for diagnostic radiology, an audit guide to their clinical review, and data collection sheets for the rapid production of reports in audit situations. It will be a useful guide for diagnostic radiology facilities wishing to improve their service to patients through timely diagnosis with minimal radiation dose.

  20. Cancer imaging phenomics toolkit: quantitative imaging analytics for precision diagnostics and predictive modeling of clinical outcome.

    Science.gov (United States)

    Davatzikos, Christos; Rathore, Saima; Bakas, Spyridon; Pati, Sarthak; Bergman, Mark; Kalarot, Ratheesh; Sridharan, Patmaa; Gastounioti, Aimilia; Jahani, Nariman; Cohen, Eric; Akbari, Hamed; Tunc, Birkan; Doshi, Jimit; Parker, Drew; Hsieh, Michael; Sotiras, Aristeidis; Li, Hongming; Ou, Yangming; Doot, Robert K; Bilello, Michel; Fan, Yong; Shinohara, Russell T; Yushkevich, Paul; Verma, Ragini; Kontos, Despina

    2018-01-01

    The growth of multiparametric imaging protocols has paved the way for quantitative imaging phenotypes that predict treatment response and clinical outcome, reflect underlying cancer molecular characteristics and spatiotemporal heterogeneity, and can guide personalized treatment planning. This growth has underlined the need for efficient quantitative analytics to derive high-dimensional imaging signatures of diagnostic and predictive value in this emerging era of integrated precision diagnostics. This paper presents cancer imaging phenomics toolkit (CaPTk), a new and dynamically growing software platform for analysis of radiographic images of cancer, currently focusing on brain, breast, and lung cancer. CaPTk leverages the value of quantitative imaging analytics along with machine learning to derive phenotypic imaging signatures, based on two-level functionality. First, image analysis algorithms are used to extract comprehensive panels of diverse and complementary features, such as multiparametric intensity histogram distributions, texture, shape, kinetics, connectomics, and spatial patterns. At the second level, these quantitative imaging signatures are fed into multivariate machine learning models to produce diagnostic, prognostic, and predictive biomarkers. Results from clinical studies in three areas are shown: (i) computational neuro-oncology of brain gliomas for precision diagnostics, prediction of outcome, and treatment planning; (ii) prediction of treatment response for breast and lung cancer, and (iii) risk assessment for breast cancer.

  1. Implementation of Point-of-Care Diagnostics in Rural Primary Healthcare Clinics in South Africa: Perspectives of Key Stakeholders.

    Science.gov (United States)

    Mashamba-Thompson, Tivani P; Jama, Ngcwalisa A; Sartorius, Benn; Drain, Paul K; Thompson, Rowan M

    2017-01-08

    Key stakeholders' involvement is crucial to the sustainability of quality point-of-care (POC) diagnostics services in low-and-middle income countries. The aim of this study was to explore key stakeholder perceptions on the implementation of POC diagnostics in rural primary healthcare (PHC) clinics in South Africa. We conducted a qualitative study encompassing in-depth interviews with multiple key stakeholders of POC diagnostic services for rural and resource-limited PHC clinics. Interviews were digitally recorded and transcribed verbatim prior to thematic content analysis. Thematic content analysis was conducted using themes guided by the World Health Organisation (WHO) quality-ASSURED (Affordable, Sensitive, Specific, User friendly, Rapid and to enable treatment at first visit and Robust, Equipment free and Delivered to those who need it) criteria for POC diagnostic services in resource-limited settings. 11 key stakeholders participated in the study. All stakeholders perceived the main advantage of POC diagnostics as enabling access to healthcare for rural patients. Stakeholders perceived the current POC diagnostic services to have an ability to meet patients' needs, but recommended further improvement of the following areas: research on cost-effectiveness; improved quality management systems; development of affordable POC diagnostic and clinic-based monitoring and evaluation. Key stakeholders of POC diagnostics in rural PHC clinics in South Africa highlighted the need to assess affordability and ensure quality assurance of current services before adopting new POC diagnostics and scaling up current POC diagnostics.

  2. Implementation of Point-of-Care Diagnostics in Rural Primary Healthcare Clinics in South Africa: Perspectives of Key Stakeholders

    Directory of Open Access Journals (Sweden)

    Tivani P. Mashamba-Thompson

    2017-01-01

    Full Text Available Introduction: Key stakeholders’ involvement is crucial to the sustainability of quality point-of-care (POC diagnostics services in low-and-middle income countries. The aim of this study was to explore key stakeholder perceptions on the implementation of POC diagnostics in rural primary healthcare (PHC clinics in South Africa. Method: We conducted a qualitative study encompassing in-depth interviews with multiple key stakeholders of POC diagnostic services for rural and resource-limited PHC clinics. Interviews were digitally recorded and transcribed verbatim prior to thematic content analysis. Thematic content analysis was conducted using themes guided by the World Health Organisation (WHO quality-ASSURED (Affordable, Sensitive, Specific, User friendly, Rapid and to enable treatment at first visit and Robust, Equipment free and Delivered to those who need it criteria for POC diagnostic services in resource-limited settings. Results: 11 key stakeholders participated in the study. All stakeholders perceived the main advantage of POC diagnostics as enabling access to healthcare for rural patients. Stakeholders perceived the current POC diagnostic services to have an ability to meet patients’ needs, but recommended further improvement of the following areas: research on cost-effectiveness; improved quality management systems; development of affordable POC diagnostic and clinic-based monitoring and evaluation. Conclusions: Key stakeholders of POC diagnostics in rural PHC clinics in South Africa highlighted the need to assess affordability and ensure quality assurance of current services before adopting new POC diagnostics and scaling up current POC diagnostics.

  3. Evolution of modern nuclear medicine tumor-imaging diagnostics in clinical oncology

    International Nuclear Information System (INIS)

    Piperkova, E.

    2000-01-01

    The evolution of current nuclear medicine diagnostic is closely related to the technical progress in imaging equipment development, and application of radiopharmaceuticals (Rphs) with a different tumor-uptake mechanism. It is the aim of the study to present groups of tumor-imaging Rphs differing by tumor uptake mechanisms, used in clinical oncology. The obtained results are described, and compared with the ones reported by other researchers. Sensitivity and specificity of Rphs for cardio-scintigraphy with 99m Tc - MIBI and 201 Tl are relatively high, amounting to 93.7% and 60% respectively, in the various tumors. These indicators depend on the stage, location, histopathology, level of malignancy and biological activity of the neoplasm. 99m Tc - MIBI scintigraphy is endowed with considerable diagnostic potential for assaying multiple drug resistance (MDR), and is also a good criterion for its elimination following anti-MDR therapy. The obtained results show that radioimmunoscintigraphy (RIS) using different radiolabeled monoclonal antibodies (MoAb) have high sensitivity and specificity respectively: 86% and 80% in ovarian carcinoma with B72.3 antiTAG; 68.6% and 92.5% in colorectal carcinoma with B73.2 antiTAG, antiCEA, antiCA 19-9; 92% and 83% in breast cancer with antiCEA, 86.8% and 67-69% in malignant melanoma with 225.28s. Receptor scintigraphy may reach up to 86% sensitivity and 100% specificity in tumors saturated with somatostatin receptors. Positron emission tomography (PET) with 18F-FDG enhances the metabolic activity of tumor cells, and attains tumor-detecting rate amounting to 97%. Tumor imaging evolution characterized by the introduction and practical implementation of different Rphs, visualizing the functional and biochemical activity of tumor cells in the primary neoplasm, sentinel lymph nodes and distant metastases. radiolabelling of a variety of new biochemical substances, including DNA and RNA, drugs and lysosomes contributes to a successful imaging

  4. Dissecting aneurysms of posterior communicating artery itself: anatomical, diagnostic, clinical, and therapeutical considerations.

    Science.gov (United States)

    Kocak, Burak; Tureci, Ercan; Kizilkilic, Osman; Islak, Civan; Kocer, Naci

    2013-09-01

    Posterior communicating artery (PCoA) itself is an unusual location for intracranial aneurysms in that isolated dissections or dissecting aneurysms are extremely rare. In the way of correct diagnosis of dissecting aneurysms of PCoA itself, a proper understanding of (1) the anatomy of the PCoA and its perforator branches, (2) some particular diagnostic features, and (3) related clinical aspects is of significant importance. Although there are no established treatment strategies for this particular type of aneurysms, the endovascular approach might be considered as a plausible one. In this paper, our scope was to report five cases with dissecting aneurysm of the PCoA itself and to discuss this rare vascular pathology from anatomical, diagnostic, clinical, and therapeutical perspectives.

  5. New laser sources for clinical treatment and diagnostics of neonatal jaundice

    Science.gov (United States)

    Hamza, Mostafa; El-Ahl, Mohammad H. S.; Hamza, Ahmad M.

    2001-06-01

    An elevated serum bilirubin concentration in the newborn infant presents a therapeutic as well as a diagnostic problem to the physician. It has long been recognized that high levels of bilirubin cause irreversible brain damage and even death. The authors introduce the use of semiconductor diode lasers and diode-pumped solid-state lasers that can be used for solving such diagnostic and therapeutic problems. These new laser sources can improve the ergonomics of using laser, enhance performance capabilities and reduce the cost of employing laser energy to pump bilirubin out of an infant's body. The choice of laser wavelengths follows the principles of bilirubinometry and phototherapy of neonatal jaundice. The wide spread use of these new laser sources for clinical monitoring and treatment of neonatal hyperbilirubinemia will be made possible as each incremental or quantum jump cost reduction is achieved. Our leading clinical experience as well as the selection rules of laser wavelengths will be presented.

  6. The diagnostic significance of clinical and radiological findings in osteogenesis imperfection

    International Nuclear Information System (INIS)

    Xu Deyong; Xu Zushan; Shen Qijie

    1997-01-01

    Purpose: To define the diagnostic criteria of osteogenesis imperfection. Materials and methods: The clinical and radiologic manifestations of 68 patients with osteogenesis imperfection were studied retrospectively. Results: (1) A generalized decrease in osseous density (osteoporosis or osteopenia) with abnormal fragility of bone (68 cases). (2) Blue sclera (61 cases). (3) Dentinogenesis imperfection with opalescent bluish-gray tint (49 cases). (4) Progressive hearing loss (prior to the age of 40 years)-premature otosclerosis (38 cases). Other abnormalities such as abnormal contour and structure (68 cases), growth retardation (49 cases), episodic diaphoresis (24 cases), with abnormal temperature regulation (16 cases), hyperplastic scars (11 cases) and tendency of subcutaneous bruise (6 cases), all these were not characteristic features. Conclusion: Among all clinical and radiological findings, osteopenia with abnormal fragility of bone; blue sclera dentinogenesis imperfection with opalescent bluish-gray tint and premature otosclerosis are the most common and characteristic findings which can be taken as the diagnostic criteria of osteogenesis imperfection

  7. Schwartz–jampel syndrome: Clinical and diagnostic phenotype of a rare genetic disorder

    Directory of Open Access Journals (Sweden)

    Bhaskara P Shelley

    2016-01-01

    Full Text Available The distinctive phenotypic, clinical, skeletal characteristics with the typical electrophysiological features of an 11-year-old male child who presented to the neurology outpatient service are described, with the objective of emphasizing the diagnostic awareness of chondrodystrophic myotonia or Schwartz–Jampel syndrome, a very rare genetic disorder. This autosomal recessive disorder due to mutations in the gene Perlecan leads to abnormal cartilage development and anomalous neuromuscular activity.

  8. A study of diagnostics expert system for accelerator applications

    International Nuclear Information System (INIS)

    Tyagi, Y.; Banerji, Anil; Kotaiah, S.

    2003-01-01

    Knowledge based techniques are proving to be useful in a number of problem domains which typically requires human expertise. Expert systems employing knowledge based techniques are a recent product of artificial intelligence. Methods developed in the artificial intelligence area can be applied with success for certain classes of problems in accelerator. Accelerators are complex devices with thousands of components. The number of possible faults or problems that can appear is enormous. A diagnostics expert system can provide great help in finding and diagnosing problems in Indus-II accelerator sub-systems. (author)

  9. Vertigo in childhood: proposal for a diagnostic algorithm based upon clinical experience.

    Science.gov (United States)

    Casani, A P; Dallan, I; Navari, E; Sellari Franceschini, S; Cerchiai, N

    2015-06-01

    The aim of this paper is to analyse, after clinical experience with a series of patients with established diagnoses and review of the literature, all relevant anamnestic features in order to build a simple diagnostic algorithm for vertigo in childhood. This study is a retrospective chart review. A series of 37 children underwent complete clinical and instrumental vestibular examination. Only neurological disorders or genetic diseases represented exclusion criteria. All diagnoses were reviewed after applying the most recent diagnostic guidelines. In our experience, the most common aetiology for dizziness is vestibular migraine (38%), followed by acute labyrinthitis/neuritis (16%) and somatoform vertigo (16%). Benign paroxysmal vertigo was diagnosed in 4 patients (11%) and paroxysmal torticollis was diagnosed in a 1-year-old child. In 8% (3 patients) of cases, the dizziness had a post-traumatic origin: 1 canalolithiasis of the posterior semicircular canal and 2 labyrinthine concussions, respectively. Menière's disease was diagnosed in 2 cases. A bilateral vestibular failure of unknown origin caused chronic dizziness in 1 patient. In conclusion, this algorithm could represent a good tool for guiding clinical suspicion to correct diagnostic assessment in dizzy children where no neurological findings are detectable. The algorithm has just a few simple steps, based mainly on two aspects to be investigated early: temporal features of vertigo and presence of hearing impairment. A different algorithm has been proposed for cases in which a traumatic origin is suspected.

  10. Effective choices for diagnostic imaging in clinical practice. Excerpts from a report of a WHO Scientific Group on Clinical Diagnostic Imaging

    International Nuclear Information System (INIS)

    1992-01-01

    There are so many different methods of diagnostic imaging that medical practitioners may need guidance to choose the best through the maze of options for each clinical problem. Advice may be required for more than just the first choice, because the first imaging procedure does not always give the desired answer and, depending on the results, further imaging may have to undertaken. The alternative is to submit the patient to a barrage of imaging and hope that one type, at least provides the diagnosis. This is a quite unacceptable way to practice medicine because of the cost and the risk of radiation damage from unnecessary examinations. The choice of the most effective imaging is often difficult and frequently controversial. The sequence to be followed vries with many factors: the equipment available, the skills of the practitioner, the expected quality of the results, the quality of interpretation, and conclusion which can be drawn

  11. Radiolabelled blood elements techniques and clinical applications

    International Nuclear Information System (INIS)

    Thakur, M.L.

    1992-01-01

    Over the past few years, in nuclear medicine, the diagnostic applications of radiolabelled blood elements in general, and of radiolabelled white blood cells in particular, have become increasingly popular. This is primarily due to the introduction of lipid soluble 111 In-oxine as an agent, which not only is an excellent and a reliable tracer for blood cells but also enables the investigators to study the in vivo cell kinetics and map the localization of labelled cells by external gamma scintigraphy. The tracer has the modest half life of 67 hours and decays with the emission of two gamma photons (173 and 247 keV) in high abundance. This technique has provided a powerful tool to study the in vivo cell kinetics in health and localize abnormal lesions in diseases which invoke intense focal cellular concentration

  12. Radiolabelled blood elements techniques and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Thakur, M L

    1993-12-31

    Over the past few years, in nuclear medicine, the diagnostic applications of radiolabelled blood elements in general, and of radiolabelled white blood cells in particular, have become increasingly popular. This is primarily due to the introduction of lipid soluble {sup 111}In-oxine as an agent, which not only is an excellent and a reliable tracer for blood cells but also enables the investigators to study the in vivo cell kinetics and map the localization of labelled cells by external gamma scintigraphy. The tracer has the modest half life of 67 hours and decays with the emission of two gamma photons (173 and 247 keV) in high abundance. This technique has provided a powerful tool to study the in vivo cell kinetics in health and localize abnormal lesions in diseases which invoke intense focal cellular concentration 5 figs, 2 tabs

  13. Nuclear based diagnostics in high-power laser applications

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, Marc; Sonnabend, Kerstin; Harres, Knut; Otten, Anke; Roth, Markus [TU Darmstadt, Institut fuer Kernphysik, Darmstadt (Germany); Vogt, Karsten; Bagnoud, Vincent [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany)

    2010-07-01

    High-power lasers allow focused intensities of >10{sup 18} W/cm{sup 2}. During the laser-solid interaction, an intense relativistic electron current is injected from the plasma into the target. One challenge is to characterize the electron dynamic close to the interaction region. Moreover, next generation high-power laser proton acceleration leads to high proton fluxes, which require novel, nuclear diagnostic techniques. We present an activation-based nuclear pyrometry for the investigation of electrons generated in relativistic laser-solid interactions. We use novel activation targets consisting of several isotopes with different photo-neutron disintegration thresholds. The electrons are decelerated inside the target via bremsstrahlung processes. The high-energy bremsstrahlung induces photo-nuclear reactions. In this energy range no disturbing low energy effects are important. Via the pyrometry the Reconstruction of the absolute yield, spectral and spatial distribution of the electrons is possible. For the characterization of proton beams we present a nuclear activation imaging spectroscopy (NAIS). The diagnostic is based on proton-neutron disintegration reactions of copper stacked in consecutive layers. An autoradiography of copper layers leads to spectrally and spatially reconstruction of the beam profile.

  14. Aptamer selection and applications for breast cancer diagnostics and therapy

    Directory of Open Access Journals (Sweden)

    Mei Liu

    2017-11-01

    Full Text Available Abstract Aptamers are short non-coding, single-stranded oligonucleotides (RNA or DNA developed through Systematic Evolution of Ligands by Exponential enrichment (SELEX in vitro. Similar to antibodies, aptamers can bind to specific targets with high affinity, and are considered promising therapeutic agents as they have several advantages over antibodies, including high specificity, stability, and non-immunogenicity. Furthermore, aptamers can be produced at a low cost and easily modified, and are, therefore, called “chemical antibodies”. In the past years, a variety of aptamers specifically bound to both breast cancer biomarkers and cells had been selected. Besides, taking advantage of nanomaterials, there were a number of aptamer-nanomaterial conjugates been developed and widely investigated for diagnostics and targeted therapy of breast cancer. In this short review, we first present a systematical review of various aptamer selection methods. Then, various aptamer-based diagnostic and therapeutic strategies of breast cancer were provided. Finally, the current problems, challenges, and future perspectives in the field were thoroughly discussed.

  15. [Clinical evaluation of female pelvic tumors : Application fields of integrated PET/MRI].

    Science.gov (United States)

    Grueneisen, J; Umutlu, L

    2016-07-01

    Integrated positron emission tomography (PET) and magnetic resonance imaging (MRI) scanning has recently become established in clinical imaging. Various studies have demonstrated the great potential of this new hybrid imaging procedure for applications in the field of oncology and the diagnostics of inflammatory processes. With initial studies demonstrating the feasibility and high diagnostic potential of PET/MRI comparable to PET-computed tomography (CT), the focus of future studies should be on the identification of application fields with a potential diagnostic benefit of PET/MRI over other established diagnostic tools. Both MRI and PET/CT are widely used in the diagnostic algorithms for malignancies of the female pelvis. A simultaneous acquisition of PET and MRI data within a single examination provides complementary information which can be used for a more comprehensive evaluation of the primary tumor as well as for whole body staging. Therefore, the aim of this article is to outline potential clinical applications of integrated PET/MRI for the diagnostic work-up of primary or recurrent gynecological neoplasms of the female pelvis.

  16. Clinical impact of diagnostic SPET investigations with a dopamine re-uptake ligand

    International Nuclear Information System (INIS)

    Loekkegaard, Annemette; Werdelin, Lene M.; Friberg, Lars

    2002-01-01

    The diagnosis of Parkinson's disease is based on clinical features with pathological verification. However, autopsy has been found to confirm a specialist diagnosis in only about 75% of cases. Especially early in the course of the disease, the clinical diagnosis can be difficult. Imaging of presynaptic dopamine transporters (DAT receptors) has provided a possible diagnostic probe in the evaluation of Parkinson's disease. The cocaine analogue [ 123 I]-2-β-carboxymethoxy-3-β(4-iodophenyl)tropane ([ 123 I]-β-CIT) is one of several radioligands that have been developed for single-photon emission tomography (SPET). The purpose of this study was to evaluate the impact of [ 123 I]-β-CIT SPET on the diagnosis and clinical management of patients with a primary, tentative diagnosis of parkinsonism. We undertook a retrospective evaluation of the clinical records of 90 consecutive patients referred to [ 123 I]-β-CIT SPET from the neurological department, Bispebjerg Hospital. In 58 subjects the scans revealed altered tracer uptake consistent with Parkinson's disease, progressive supranuclear palsy and multiple system atrophy. A significant change in the management or treatment because of the scan was found in 25 patients (28%). The sensitivity of the examination was 97% and the specificity 83%. In conclusion, a significant clinical impact of DAT receptor SPET imaging was found. DAT receptor imaging is a useful diagnostic probe in patients with a possible diagnosis of parkinsonism. (orig.)

  17. Optical coherence tomography—current technology and applications in clinical and biomedical research

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Sander, Birgit; Mogensen, Mette

    2011-01-01

    such as birefringence, motion, or the distributions of certain substances can be detected with high spatial resolution. Its main field of application is biomedical imaging and diagnostics. In ophthalmology, OCT is accepted as a clinical standard for diagnosing and monitoring the treatment of a number of retinal...

  18. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    International Nuclear Information System (INIS)

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE's nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer

  19. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE`s nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer.

  20. Clinical impact of recurrently mutated genes on lymphoma diagnostics: state-of-the-art and beyond.

    Science.gov (United States)

    Rosenquist, Richard; Rosenwald, Andreas; Du, Ming-Qing; Gaidano, Gianluca; Groenen, Patricia; Wotherspoon, Andrew; Ghia, Paolo; Gaulard, Philippe; Campo, Elias; Stamatopoulos, Kostas

    2016-09-01

    Similar to the inherent clinical heterogeneity of most, if not all, lymphoma entities, the genetic landscape of these tumors is markedly complex in the majority of cases, with a rapidly growing list of recurrently mutated genes discovered in recent years by next-generation sequencing technology. Whilst a few genes have been implied to have diagnostic, prognostic and even predictive impact, most gene mutations still require rigorous validation in larger, preferably prospective patient series, to scrutinize their potential role in lymphoma diagnostics and patient management. In selected entities, a predominantly mutated gene is identified in almost all cases (e.g. Waldenström's macroglobulinemia/lymphoplasmacytic lymphoma and hairy-cell leukemia), while for the vast majority of lymphomas a quite diverse mutation pattern is observed, with a limited number of frequently mutated genes followed by a seemingly endless tail of genes with mutations at a low frequency. Herein, the European Expert Group on NGS-based Diagnostics in Lymphomas (EGNL) summarizes the current status of this ever-evolving field, and, based on the present evidence level, segregates mutations into the following categories: i) immediate impact on treatment decisions, ii) diagnostic impact, iii) prognostic impact, iv) potential clinical impact in the near future, or v) should only be considered for research purposes. In the coming years, coordinated efforts aiming to apply targeted next-generation sequencing in large patient series will be needed in order to elucidate if a particular gene mutation will have an immediate impact on the lymphoma classification, and ultimately aid clinical decision making. Copyright© Ferrata Storti Foundation.

  1. The Diagnostic and Prognostic Value of a Dual-Tasking Paradigm in a Memory Clinic.

    Science.gov (United States)

    Nielsen, Malene Schjnning; Simonsen, Anja Hviid; Siersma, Volkert; Hasselbalch, Steen Gregers; Hoegh, Peter

    2018-01-01

    Daily living requires the ability to perform dual-tasking. As cognitive skills decrease in dementia, performing a cognitive and motor task simultaneously become increasingly challenging and subtle gait abnormalities may even be present in pre-dementia stages. Therefore, a dual-tasking paradigm, such as the Timed Up and Go-Dual Task (TUG-DT), may be useful in the diagnostic assessment of mild cognitive impairment (MCI). To investigate the diagnostic and prognostic ability of a dual-tasking paradigm in patients with MCI or mild Alzheimer's disease (AD) and to evaluate the association between the dual-tasking paradigm and cerebrospinal fluid (CSF) AD biomarkers. The study is a prospective cohort study conducted in a clinical setting in two memory clinics. Eighty-six patients were included (28 MCI, 17 AD, 41 healthy controls (HC)). The ability to perform dual-tasking was evaluated by the TUG-DT. Patients underwent a standardized diagnostic assessment and were evaluated to determine progression yearly. ROC curve analysis illustrated a high discriminative ability of the dual-tasking paradigm in separating MCI patients from HC (AUC: 0.78, AUC: 0.82) and a moderate discriminative ability in separating MCI from AD (AUC: 0.73, AUC: 0.55). Performance discriminated clearly between all groups (p paradigm for progression and rate of cognitive decline. A moderately strong correlation between the dual-tasking paradigm and CSF AD biomarkers was observed. In our study, we found that patients with MCI and mild AD have increasing difficulties in dual-tasking compared to healthy elderly. Hence, the dual-tasking paradigm may be a potential complement in the diagnostic assessment in a typical clinical setting.

  2. Clinical applications of 7 T MRI in the brain

    International Nuclear Information System (INIS)

    Kolk, Anja G. van der; Hendrikse, Jeroen; Zwanenburg, Jaco J.M.; Visser, Fredy; Luijten, Peter R.

    2013-01-01

    This review illustrates current applications and possible future directions of 7 Tesla (7 T) Magnetic Resonance Imaging (MRI) in the field of brain MRI, in clinical studies as well as clinical practice. With its higher signal-to-noise (SNR) and contrast-to-noise ratio (CNR) compared to lower field strengths, high resolution, contrast-rich images can be obtained of diverse pathologies, like multiple sclerosis (MS), brain tumours, aging-related changes and cerebrovascular diseases. In some of these diseases, additional pathophysiological information can be gained compared to lower field strengths. Because of clear depiction of small anatomical details, and higher lesion conspicuousness, earlier diagnosis and start of treatment of brain diseases may become possible. Furthermore, additional insight into the pathogenesis of brain diseases obtained with 7 T MRI could be the basis for new treatment developments. However, imaging at high field comes with several limitations, like inhomogeneous transmit fields, a higher specific absorption rate (SAR) and, currently, extensive contraindications for patient scanning. Future studies will be aimed at assessing the advantages and disadvantages of 7 T MRI over lower field strengths in light of clinical applications, specifically the additional diagnostic and prognostic value of 7 T MRI

  3. Clinical applications of 7 T MRI in the brain

    Energy Technology Data Exchange (ETDEWEB)

    Kolk, Anja G. van der, E-mail: A.G.vanderKolk@umcutrecht.nl [Department of Radiology, University Medical Center Utrecht, Postbox 85500, 3508 GA Utrecht (Netherlands); Hendrikse, Jeroen, E-mail: J.Hendrikse@umcutrecht.nl [Department of Radiology, University Medical Center Utrecht, Postbox 85500, 3508 GA Utrecht (Netherlands); Zwanenburg, Jaco J.M., E-mail: J.J.M.Zwanenburg@umcutrecht.nl [Department of Radiology, University Medical Center Utrecht, Postbox 85500, 3508 GA Utrecht (Netherlands); Image Sciences Institute, University Medical Center Utrecht (Netherlands); Visser, Fredy, E-mail: F.Visser-2@umcutrecht.nl [Department of Radiology, University Medical Center Utrecht, Postbox 85500, 3508 GA Utrecht (Netherlands); Philips Healthcare, Best (Netherlands); Luijten, Peter R., E-mail: P.Luijten@umcutrecht.nl [Department of Radiology, University Medical Center Utrecht, Postbox 85500, 3508 GA Utrecht (Netherlands)

    2013-05-15

    This review illustrates current applications and possible future directions of 7 Tesla (7 T) Magnetic Resonance Imaging (MRI) in the field of brain MRI, in clinical studies as well as clinical practice. With its higher signal-to-noise (SNR) and contrast-to-noise ratio (CNR) compared to lower field strengths, high resolution, contrast-rich images can be obtained of diverse pathologies, like multiple sclerosis (MS), brain tumours, aging-related changes and cerebrovascular diseases. In some of these diseases, additional pathophysiological information can be gained compared to lower field strengths. Because of clear depiction of small anatomical details, and higher lesion conspicuousness, earlier diagnosis and start of treatment of brain diseases may become possible. Furthermore, additional insight into the pathogenesis of brain diseases obtained with 7 T MRI could be the basis for new treatment developments. However, imaging at high field comes with several limitations, like inhomogeneous transmit fields, a higher specific absorption rate (SAR) and, currently, extensive contraindications for patient scanning. Future studies will be aimed at assessing the advantages and disadvantages of 7 T MRI over lower field strengths in light of clinical applications, specifically the additional diagnostic and prognostic value of 7 T MRI.

  4. Development and clinical application of In Vivo dosimetry for radiotherapy

    International Nuclear Information System (INIS)

    Honda, Hirofumi; Oita, Masataka; Tominaga, Masahide; Oto, Yoshihiro

    2016-01-01

    In practical radiotherapy, it is important to deliver radiation to the target correctly and safely according to the treatment planning. The control of radiation dose delivered to each patient in radiotherapy mainly relies on the prediction based on the result of pre-treatment verification and irradiation accuracy of treatment machines. In Vivo dosimetry in radiotherapy is the procedure of quality assurance by the way of direct measurement for the patient whether the calculated prescribed dose in the treatment planning is delivered precisely. The history of In Vivo dosimetry is relatively long, and the TLD dosimetry for clinical radiotherapy started in early 1970's. After 1980's, owing to the development of semiconductor devices such as diode detectors, semiconductor arrays, the clinical applications for the dosimetry and diagnostic radiation imaging devices which contributed to the development of electric portal imaging devices and 2D semiconductor detectors were introduced. In recent years, these radiation measurement devices and non-invasive methods have been developed, they are becoming widespread as clinical practice. In this paper, we reviewed the In Vivo dosimetry devices and their characteristics, and technical application for radiotherapy. (author)

  5. Clinical applications of PET/CT

    International Nuclear Information System (INIS)

    Le Ngoc Ha

    2011-01-01

    The purpose of this article is to review the evolution of PET, PET/CT focusing on the technical aspects, PET radiopharmaceutical developments and current clinical applications as well. The newest technologic advances have been reviewed, including improved crystal design, acquisition modes, reconstruction algorithms, etc. These advancements will continue to improve contrast, decrease noise, and increase resolution. Combined PET/CT system provides faster attenuation correction and useful anatomic correlation to PET functional information. A number of new radiopharmaceuticals used for PET imaging have been developed, however, FDG have been considered as the principal PET radiotracer. The current clinical applications of PET and PET/CT are widespread and include oncology, cardiology and neurology. (author)

  6. [Genetic diagnostics of pathogenic splicing abnormalities in the clinical laboratory--pitfalls and screening approaches].

    Science.gov (United States)

    Niimi, Hideki; Ogawa, Tomomi; Note, Rhougou; Hayashi, Shirou; Ueno, Tomohiro; Harada, Kenu; Uji, Yoshinori; Kitajima, Isao

    2010-12-01

    In recent years, genetic diagnostics of pathogenic splicing abnormalities are increasingly recognized as critically important in the clinical genetic diagnostics. It is reported that approximately 10% of pathogenic mutations causing human inherited diseases are splicing mutations. Nonetheless, it is still difficult to identify splicing abnormalities in routine genetic diagnostic settings. Here, we studied two different kinds of cases with splicing abnormalities. The first case is a protein S deficiency. Nucleotide analyses revealed that the proband had a previously reported G to C substitution in the invariant AG dinucleotide at the splicing acceptor site of intronl/exon2, which produces multiple splicing abnormalities resulting in protein S deficiency. The second case is an antithrombin (AT) deficiency. This proband had a previously reported G to A substitution, at nucleotide position 9788 in intron 4, 14 bp in front of exon 5, which created a de novo exon 5 splice site and resulted in AT deficiency. From a practical standpoint, we discussed the pitfalls, attentions, and screening approaches in genetic diagnostics of pathogenic splicing abnormalities. Due to the difficulty with full-length sequence analysis of introns, and the lack of RNA samples, splicing mutations may escape identification. Although current genetic testing remains to be improved, to screen for splicing abnormalities more efficiently, it is significant to use an appropriate combination of various approaches such as DNA and/or RNA samples, splicing mutation databases, bioinformatic tools to detect splice sites and cis-regulatory elements, and in vitro and/or in vivo experimentally methods as needed.

  7. The application of microRNAs in cancer diagnostics

    DEFF Research Database (Denmark)

    Sørensen, Karina Dalsgaard; Ostenfeld, Marie Stampe; Kristensen, Helle

    2012-01-01

    hallmark of human cancer. Furthermore, miRNAs have been found to be a new class of promising cancer biomarkers with potential to improve the accuracy of diagnosis and prognosis in several hematologic and solid malignancies, as well as to predict response to specific treatments. Recent studies have......MicroRNAs (miRNAs) play important biological roles in cancer development and progression. During the past decade, widespread use of novel high-throughput technologies for miRNA profiling (e.g., microarrays and next-generation sequencing) has revealed deregulation of miRNA expression as a common...... identified exosome-associated tumor-derived miRNAs in, e.g., blood samples from cancer patients, suggesting that miRNAs may be useful as circulation biomarkers for noninvasive diagnostic testing. In this chapter, we review the current state of development of miRNAs as cancer biomarkers with examples from...

  8. Applications of optical fibers in nuclear test diagnostics

    International Nuclear Information System (INIS)

    Lyons, P.B.; Hodson, E.K.; Looney, L.D.

    1980-01-01

    Two new plasma diagnostic experiments have been successfully fielded on nuclear device tests at NTS. Both systems rely on the unique advantages provided by optical fiber technology and both systems provide new diagnostic capabilities that previously were beyond the state-of-the-art in coaxial cable systems. One system addresses the need to record e wide bandwidth data on gamma-ray sources. Over the long (< 1 km) distances that characterize NTS testing, the bandwidth of coaxial cable systems is usually limited to < 200 to 400 MHz even with extensive equalization. The new system uses the Cerenkov process to generate light in a converter material. High bandwidth fibers and detectors are used to approach a 1-GHz bandwidth. In this case fibers provided the bandwidth capability. The second system provides time and space resolution of a neutron source on a fast (ns) time scale. Previous systems have utilized either an array of neutron detectors with individual coaxial cables or a fast scintillator viewed by a gated image intensifier. For a large number of channels, the coaxial system becomes very costly and is subject to potentially severe EMI concerns. The gated intensifier system requires complex electronics and accurate timing and can be affected by EMI. An alternative system is described which provides continuous time coverage with limited spatial resolution. Complete freedom from EMI is achieved through the use of optical data collection and transmission. The optical fibers offered a major (2 to 3 times) cost savings and a large weight savings relative to the coax system. Each system is discussed

  9. [Multi-centre clinical assessment of the Russian language version of the Diagnostic Interview for Psychoses].

    Science.gov (United States)

    Smirnova, D A; Petrova, N N; Pavlichenko, A V; Martynikhin, I A; Dorofeikova, M V; Eremkin, V I; Izmailova, O V; Osadshiy, Yu Yu; Romanov, D V; Ubeikon, D A; Fedotov, I A; Sheifer, M S; Shustov, A D; Yashikhina, A A; Clark, M; Badcock, J; Watterreus, A; Morgan, V; Jablensky, A

    2018-01-01

    The Diagnostic Interview for Psychoses (DIP) was developed to enhance the quality of diagnostic assessment of psychotic disorders. The aim of the study was the adaptation of the Russian language version and evaluation of its validity and reliability. Ninety-eight patients with psychotic disorders (89 video recordings) were assessed by 12 interviewers using the Russian version of DIP at 7 clinical sites (in 6 cities of the Russian Federation). DIP ratings on 32 cases of a randomized case sample were made by 9 interviewers and the inter-rater reliability was compared with the researchers' DIP ratings. Overall pairwise agreement and Cohen's kappa were calculated. Diagnostic validity was evaluated on the basis of comparing the researchers' ratings using the Russian version of DIP with the 'gold standard' ratings of the same 62 clinical cases from the Western Australia Family Study Schizophrenia (WAFSS). The mean duration of the interview was 47±21 minutes. The Kappa statistic demonstrated a significant or almost perfect level of agreement on the majority of DIP items (84.54%) and a significant agreement for the ICD-10 diagnoses generated by the DIP computer diagnostic algorithm (κ=0.68; 95% CI 0.53,0.93). The level of agreement on the researchers' diagnoses was considerably lower (κ=0.31; 95% CI 0.06,0.56). The agreement on affective and positive psychotic symptoms was significantly higher than agreement on negative symptoms (F(2,44)=20.72, pRussian language version of DIP was confirmed by 73% (45/62) of the Russian DIP diagnoses matching the original WAFSS diagnoses. Among the mismatched diagnoses were 80 cases with a diagnosis of F20 Schizophrenia in the medical documentation compared to the researchers' F20 diagnoses in only 68 patients and in 62 of the DIP computerized diagnostic outputs. The reported level of subjective difficulties experienced when using the DIP was low to moderate. The results of the study confirm the validity and reliability of the Russian

  10. Clinical Efficacy of Various Diagnostic Tests for Small Bowel Tumors and Clinical Features of Tumors Missed by Capsule Endoscopy

    Directory of Open Access Journals (Sweden)

    Jung Wan Han

    2015-01-01

    Full Text Available Background. We aimed to evaluate the efficacy of various diagnostic tools such as computerized tomography (CT, small bowel follow-through (SBFT, and capsule endoscopy (CE in diagnosing small bowel tumors (SBTs. Additionally, we aimed to evaluate the clinical features of SBTs missed by CE. Methods. We retrospectively studied 79 patients with histologically proven SBT. Clinical data were analyzed with particular attention to the efficacy of CT, SBFT, and CE in detecting SBT preoperatively. We also analyzed the clinical features of SBTs missed by CE. Results. The most common symptoms of SBT were bleeding (43% and abdominal pain (13.9%. Diagnostic yields were as follows: CT detected 55.8% of proven SBTs; SBFT, 46.1%; and CE, 83.3%. The sensitivity for detecting SBTs was 40.4% for CT, 43.9% for SBFT, and 79.6% for CE. Two patients with nondiagnostic but suspicious findings on CE and seven patients with negative findings on CE were eventually found to have SBT. These nine patients were eventually diagnosed with gastrointestinal stromal tumor (4, small polyps (3, inflammatory fibroid polyp (1, and adenocarcinoma (1. These tumors were located in the proximal jejunum (5, middle jejunum (1, distal jejunum (1, and proximal ileum (1. Conclusion. CE is more efficacious than CT or SBFT for detecting SBTs. However, significant tumors may go undetected with CE, particularly when located in the proximal jejunum.

  11. Development of clinical application of radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Sook; Yoo, Seoung Yul; Yoo, Hyung Jun [and others

    2000-04-01

    The aim is to develop the clinical radiation therapy techniques, which increase local control and cure rate of cancer. The contents were 1. technique of stereotactic radiotherapy 2. technique of intraoperative radiation therapy(IORT) 3. technique of fractionated radiotherapy 4. technique of 3D conformal therapy 5. chemoradiotherapy in lung cancer, rectal cancer and biliopancreatic cancer 6. network based information communication system of radiation oncology 7. animal studies for the best application of chemoradiotherapy and for elucidating mechanism of slide effect in radiotherapy. The results were 1. completion of quality assurance protocol, frame and mounting system 2. completion of applicator of IORT 3. clinical protocol of fractionated radiotherapy 4. clinical protocol of 3D conformal therapy for brain, head and neck, breast and lung cancer 5. completion of multimodality treatment protocol for lung, rectal and biliopancreatic cancer 6. completion of database system for patient information and simulation image 7. standardization of estimation for radiation induced pneumonitis in animal model. Future plans are (1) developed fractionated stereotactic radiotherapy system will be commercialized (2) developed applicator of brachytherapy for IORT will be commercialized (3) 3D conformal therapy will increase local control rate for brain tumor and decrease complications such as zerostomia after treatment for nasopharygeal cancer (4) training manpower and skills for randomized clinical trial (5) suggest possibility of clinical usefulness of oral 5-fluorouracil (6) to provide basic technique for electric chart (7) promote developing database system for image information (8) also in view of double edge sword effect of NO, it is possible to modify the NO production from irradiation to increase the tolerance to radiation.

  12. Development of clinical application of radiation

    International Nuclear Information System (INIS)

    Kim, Mi Sook; Yoo, Seoung Yul; Yoo, Hyung Jun

    2000-04-01

    The aim is to develop the clinical radiation therapy techniques, which increase local control and cure rate of cancer. The contents were 1. technique of stereotactic radiotherapy 2. technique of intraoperative radiation therapy(IORT) 3. technique of fractionated radiotherapy 4. technique of 3D conformal therapy 5. chemoradiotherapy in lung cancer, rectal cancer and biliopancreatic cancer 6. network based information communication system of radiation oncology 7. animal studies for the best application of chemoradiotherapy and for elucidating mechanism of slide effect in radiotherapy. The results were 1. completion of quality assurance protocol, frame and mounting system 2. completion of applicator of IORT 3. clinical protocol of fractionated radiotherapy 4. clinical protocol of 3D conformal therapy for brain, head and neck, breast and lung cancer 5. completion of multimodality treatment protocol for lung, rectal and biliopancreatic cancer 6. completion of database system for patient information and simulation image 7. standardization of estimation for radiation induced pneumonitis in animal model. Future plans are 1) developed fractionated stereotactic radiotherapy system will be commercialized 2) developed applicator of brachytherapy for IORT will be commercialized 3) 3D conformal therapy will increase local control rate for brain tumor and decrease complications such as zerostomia after treatment for nasopharygeal cancer 4) training manpower and skills for randomized clinical trial 5) suggest possibility of clinical usefulness of oral 5-fluorouracil 6) to provide basic technique for electric chart 7) promote developing database system for image information 8) also in view of double edge sword effect of NO, it is possible to modify the NO production from irradiation to increase the tolerance to radiation

  13. An evaluation of the diagnostic value of different skin tests with egg in clinically egg-allergic children having atopic dermatitis

    DEFF Research Database (Denmark)

    Hansen, Tine K; Høst, Arne; Bindslev-Jensen, Carsten

    2004-01-01

    Skin testing is a common diagnostic procedure in food allergy, but the final diagnosis of food allergy is based on the clinical response to food challenge. We studied the value of the skin prick-prick test (SPT), skin application food test (SAFT) and atopy patch test (APT) with fresh egg extract......-allergic children were positive in SPT and 40-60% in APT. In APT and in SPT false-positive reactions to egg were observed. In this study comprising a small number of patients including control subjects, neither SAFT nor APT with fresh whole egg extract were able to increase the diagnostic accuracy in detecting egg...

  14. Adaptive Technology Application for Vibration-Based Diagnostics of Roller Bearings on Industrial Plants

    Directory of Open Access Journals (Sweden)

    Mironov Aleksey

    2014-09-01

    Full Text Available Roller bearings are widely used in equipment of different applications; therefore, the issues related to the assessment of bearing technical state and localization of bearing faults are quite important and relevant. The reason is that technical state of a bearing is a critical component, which determines efficiency of a mechanism or equipment. For bearings inspection and diagnostics, various methods of vibration-based diagnostics are used. The adaptive technology for vibration-based diagnostics developed in „D un D centrs” is an effective tool for evaluation of technical state of bearings in operation compared to the existing SKF method.

  15. Application aspects of advanced antenna diagnostics with the 3D reconstruction algorithm

    DEFF Research Database (Denmark)

    Cappellin, Cecilia; Pivnenko, Sergey

    2015-01-01

    This paper focuses on two important applications of the 3D reconstruction algorithm of the commercial software DIATOOL for antenna diagnostics. The first one is the accurate and detailed identification of array malfunctioning, thanks to the available enhanced spatial resolution of the reconstruct...... fields and currents. The second one is the filtering of the scattering from support structures and feed network leakage. Representative experimental results are presented and guidelines on the recommended measurement parameters for obtaining the best diagnostics results are provided....

  16. Clinical neuroanatomy and diagnostic imaging of the skull. 2. rev. and enlarged ed.

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1991-01-01

    In the last few years, the techniques of CT, MRI, PET and utrasonography have been improved in their diagnostic efficiency, but in spite of the much enhanced resolution achievable with the new techniques, a large part of the neurofunctional systems that are of great significance to clinical diagnostic evaluation remains in the dark. The local structure of the neurofunctional systems is derived from the data describing the position of the conductive structures such as cerebral ventricles or typical cerebral sulci or gyri. A good knowledge of the three-dimensional topography of the neuroanatomy in the skull is required for this purpose, and this is what the book at hand is intended to confer. The arteries and their vascular environment are shown in the frontal, sagittal and axial plane and are compared with drawings produced from angiographies. The information given covers the cranium viscerale, the craniocervical neighbouring areas, and the motor innervation areas of the skull. The term 'diagnostic imaging of the skull' comprises the whole head and the transitional zones. The illustration of the neurofunctional system anatomy in the tomogram presented in this book is a source of information that may serve as a guide for pathfinding in CT, MRI, PET and ultrasonography. In addition, the knowledge found in the book will help to assign clinical data to pathologic findings revealed by CT or MRI. (orig.) With 596 mostly coloured figs [de

  17. Multifunctional Nanomaterials Utilizing Hybridization Chain Reaction for Molecular Diagnostics and Bioanalytical Applications

    Science.gov (United States)

    Rana, Md. Muhit

    DNA nanotechnology has shown great promise in molecular diagnostic, bioanalytical and biomedical applications. The great challenge of detecting target analytes, biomarkers and small molecules, in molecular diagnostics is low yield sensitivity. To address this challenge, different nanomaterials have been used for a long time and to date there is no such cost-effective bioanalytical technique which can detect these target biomarkers (DNA, RNA, circulating DNA/miRNA) or environmental heavy metal ions (Hg2+ and Ag+) in a cost-effective and efficient manner. Herein, we initially discuss two possible bioanalytical detection methods- a) colorimetric and b) fluorometric assays which are very popular nowadays due to their distinctive spectroscopic properties. Finally, we report the promising colorimetric assay using a novel DNA based amplification strategy know as hybridization chain reaction (HCR) for potential application in the visual detection of low copies of biomarkers (miRNAs as little as 20 femtomole in an RNA pool and cell extracts in seven different combinations and Ebola virus DNA as low as 400 attomoles in liquid biopsy mimics in sixteen different combinations), environmental and biological heavy metal ions (mercury and silver concentrations as low as 10 pM in water, soil and urine samples) and also successfully applied to a molecular logic gate operation to distinguish OR and AND logic gates. No results showed any false-positive or false-negative information. On the other hand, we also discuss the future possibilities of HCR amplification technology, which is very promising for fluorometric bioanalysis. The HCR based nanoprobe technology has numerous remarkable advantages over other methods. It is re-programmable, simple, inexpensive, easy to assemble and operate and can be performed with visual and spectroscopic read-outs upon recognition of the target analytes. This rapid, specific and sensitive approach for biomarkers and heavy metal ion detection generates

  18. Recent diagnostic and therapeutic approaches to prenatally and perinatally diagnosed hydronephrosis and their implementation in the University Clinical Hospital Mostar.

    Science.gov (United States)

    Mandić, Vjekoslav; Martinović, Vlatka; Kvesić, Ante; Bukvić, Nado; Skitarelić, Nataša; Brekalo, Zdrinko; Ivanković, Krunoslav; Šetka, Violeta

    2015-03-01

    A shift of the diagnostics of urological malformations towards the fetal age by means of ultrasound, especially hydronephrosis which, apart from reflux, is the most frequent developmental urological disorder, opened many dilemmas and debates. In the course of more than three decades the application of this diagnostic approach to the problem of hydrone- phrosis became a routine clinical practice in all modern clinics. In this paper we present the problems related to this diagnostic method and its delayed application in the Mostar University Clinical Hospital. Along with the exposition of a general approach to the problem of hydronephrosis we briefly present our modest collection of cases which points to the most recent trend of a vigorous medical development in this region, despite unfavorable overall conditions which prevailed so far. The observation included 56 children with prenatal, perinatal and early age determination of pyelon dilatation by means of ultrasonic exploration who were treated surgically. Of this number 32 (57.14%) were male, and 24 (42.86%) female children. Of the observed patients 56 had unilateral and 6 had bilateral pyelon dilatation so that 62 kidneys in all were observed and treated. The dilatation was determined prenatally in 24 (38.7%) out of 62 kidneys observed in all, in 7 (11.29%) the disorder was observed perinatally and in remaining 31 cases (49.9%) it manifested during early childhood, school age, even at the age of pre-puberty. Of the children with prenatally and perinatally determined dilatation, in 14 (45.16%) out of 31 (100.0%) observed kidneys the ap radius of the dilated pyelon was between 10-15 mm, and in 17 (54.84%) more than 15 mm. Along with other examinations (MAG3 and DMSA) the patients were followed-up by ultrasonic exploration of the observed kidney for 6 to 30 (average 18) months after postnatal diagnosis; the ultrasonic exploration was repeated in intervals of 6 months. Within 12 months of birth surgical intervention

  19. Assessing FDG-PET diagnostic accuracy studies to develop recommendations for clinical use in dementia.

    Science.gov (United States)

    Boccardi, Marina; Festari, Cristina; Altomare, Daniele; Gandolfo, Federica; Orini, Stefania; Nobili, Flavio; Frisoni, Giovanni B

    2018-04-30

    FDG-PET is frequently used as a marker of synaptic damage to diagnose dementing neurodegenerative disorders. We aimed to adapt the items of evidence quality to FDG-PET diagnostic studies, and assess the evidence available in current literature to assist Delphi decisions for European recommendations for clinical use. Based on acknowledged methodological guidance, we defined the domains, specific to FDG-PET, required to assess the quality of evidence in 21 literature searches addressing as many Population Intervention Comparison Outcome (PICO) questions. We ranked findings for each PICO and fed experts making Delphi decisions for recommending clinical use. Among the 1435 retrieved studies, most lacked validated measures of test performance, an adequate gold standard, and head-to-head comparison of FDG-PET and clinical diagnosis, and only 58 entered detailed assessment. Only two studies assessed the accuracy of the comparator (clinical diagnosis) versus any kind of gold-/reference-standard. As to the index-test (FDG-PET-based diagnosis), an independent gold-standard was available in 24% of the examined papers; 38% used an acceptable reference-standard (clinical follow-up); and 38% compared FDG-PET-based diagnosis only to baseline clinical diagnosis. These methodological limitations did not allow for deriving recommendations from evidence. An incremental diagnostic value of FDG-PET versus clinical diagnosis or lack thereof cannot be derived from the current literature. Many of the observed limitations may easily be overcome, and we outlined them as research priorities to improve the quality of current evidence. Such improvement is necessary to outline evidence-based guidelines. The available data were anyway provided to expert clinicians who defined interim recommendations.

  20. MYCOPLASMA INFECTION: CLINICAL TYPES, VARIATIONS OF CLINICAL COURSE AND DIAGNOSTIC MISTAKES

    Directory of Open Access Journals (Sweden)

    M.S. Savenkova

    2013-01-01

    Full Text Available Aim: to assess clinical course of various types of mycoplasma infection during the last epidemic (September 2012 – February 2013 according to the positive results of serological analyses. Patients and methods: 3553 laboratory tests were performed, 177 (20% positive results of mycoplasma were detected. During the study clinical types, gender and age of patients were analyzed; special characteristics of clinical course of mycoplasma pneumonia were identified. Results: among 78 patients with pneumonia severe form was detected only in one. Twenty five percent of patients had ENT-diseases. The authors performed comparative analysis of antibacterial treatment (first-line and macrolides. The duration of X-ray changes depended on treatment scheme; the best results were achieved in children who were administered combined treatment with first-line (cephalosporin and macrolide in suspension. Conclusions: during the period of 2012–2013 yy pneumonia has had a moderate clinical course, rarely — with complications. In 25% of children diseases of ENT organs were diagnosed. Mycoplasma was most often associated with chlamydia and types 1 and 2 of herpes simplex viruses, which is necessary to be considered in determination of therapy regimen. In treatment it is preferably to use combination of cephalosporin and macrolide in suspension.

  1. Diagnostic accuracy of clinical and blood examination for sepsis in potentially infected neonates

    Directory of Open Access Journals (Sweden)

    Ari Mulyani

    2006-10-01

    Full Text Available Background Neonatal sepsis remains a diagnostic challenge due to its nonspesific symptoms and signs. Blood culture as the gold standard is still a problem because it takes time, is expensive, and not every health facility is able to perionn. Objective To evaluate the diagnostic accuracy of clinical symptoms, hematologic findings, and C-reactive protein (CRP in neonatal sepsis. Methods Samples were taken from potentially infected neonates admitted to the Matemal-Perinatal Unit of Sardjito Hospital, between December 1st, 2000 and March 31st, 2001 using at least one of the criteria: prematurity, very low birth weight infants, matemal pyrexia during delivery, premature membrane rupture, or thick, cloudy amniotic fluid. Clinical symptoms, total leukocyte, neutrophil, platelet count, CRP, and blood culture as the gold standard were examined. Results Among 99 neonates enrolled, the sensitivity, specificity, positive and negative predictive value of clinical symptoms were 79.3%, 75.7%, 57.5%, and 89.9%, respectively; leukopenia/leukocytosis were 27.6%, 85.7%, 44.4%, and 74.1%; neutropenia! neutrophilia were 41.4%, 71.4%, 37.5%, and 74.6%; thrombocytopenia were 79.3%, 51.8%, 40.4%, and 85.7%; positive CRP were 58.6%,78.6%,53.1%, and 82.1%. Parallel tests increased the sensitivity up to 89.7%. Specificity, positive and negative predictive value, and likelihood ratio were 44.3%, 40%, 91.2%, and 1.6, respectively. Serial tests increased the specificity up to 88.6%. Sensitivity, positive and negative predictive value, and likelihood ratio were 58.6%, 68%, 83.8%, and 5.1, respectively. Conclusion Clinical sepsis, thrombocytopenia, and CRP are sufficiently accurate as diagnostic tests for sepsis in potentially infected neonates. Parallel tests will increase the sensitivity, while serial tests increase the specificity.

  2. A Diagnostic Model for Dementia in Clinical Practice-Case Methodology Assisting Dementia Diagnosis.

    Science.gov (United States)

    Londos, Elisabet

    2015-04-02

    Dementia diagnosis is important for many different reasons. Firstly, to separate dementia, or major neurocognitive disorder, from MCI (mild cognitive impairment), mild neurocognitive disorder. Secondly, to define the specific underlying brain disorder to aid treatment, prognosis and decisions regarding care needs and assistance. The diagnostic method of dementias is a puzzle of different data pieces to be fitted together in the best possible way to reach a clinical diagnosis. Using a modified case methodology concept, risk factors affecting cognitive reserve and symptoms constituting the basis of the brain damage hypothesis, can be visualized, balanced and reflected against test results as well as structural and biochemical markers. The model's origin is the case method initially described in Harvard business school, here modified to serve dementia diagnostics.

  3. Development of an instrument to measure the clinical learning environment in diagnostic radiology

    International Nuclear Information System (INIS)

    Bloomfield, L.; Subramaniam, R.

    2008-01-01

    A clinical learning environment survey instrument was developed that provided insights into diagnostic radiology trainees' perceptions of the culture and context of the hospital-based training programme. The survey was completed by trainees allocated to 37 important training hospitals in Australia, New Zealand and Singapore in 2006. The main findings were that most obvious strengths of the diagnostic radiology programme are the wide variety of work-based learning opportunities and the social atmosphere. These were well regarded in all training sites. Work overload was seen as a significant problem in most hospitals and will probably remain a challenge. The areas that are most likely to repay efforts to bring about change are supervision and feedback. The study provides baseline data against which the influence of changes to the training programme may be evaluated.

  4. Cushing Syndrome: Diagnostic Workup and Imaging Features, With Clinical and Pathologic Correlation.

    Science.gov (United States)

    Wagner-Bartak, Nicolaus A; Baiomy, Ali; Habra, Mouhammed Amir; Mukhi, Shalini V; Morani, Ajaykumar C; Korivi, Brinda R; Waguespack, Steven G; Elsayes, Khaled M

    2017-07-01

    Cushing syndrome (CS) is a constellation of clinical signs and symptoms resulting from chronic exposure to excess cortisol, either exogenous or endogenous. Exogenous CS is most commonly caused by administration of glucocorticoids. Endogenous CS is subdivided into two types: adrenocorticotropic hormone (ACTH) dependent and ACTH independent. Cushing disease, which is caused by a pituitary adenoma, is the most common cause of ACTH-dependent CS for which pituitary MRI can be diagnostic, with bilateral inferior petrosal sinus sampling useful in equivocal cases. In ectopic ACTH production, which is usually caused by a tumor in the thorax (e.g., small cell lung carcinoma, bronchial and thymic carcinoids, or medullary thyroid carcinoma) or abdomen (e.g., gastroenteropancreatic neuroendocrine tumors or pheochromocytoma), CT, MRI, and nuclear medicine tests are used for localizing the source of ACTH. In ACTH-independent CS, which is caused by various adrenal abnormalities, adrenal protocol CT or MRI is usually diagnostic.

  5. Moving beyond quality control in diagnostic radiology and the role of the clinically qualified medical physicist.

    Science.gov (United States)

    Delis, H; Christaki, K; Healy, B; Loreti, G; Poli, G L; Toroi, P; Meghzifene, A

    2017-09-01

    Quality control (QC), according to ISO definitions, represents the most basic level of quality. It is considered to be the snapshot of the performance or the characteristics of a product or service, in order to verify that it complies with the requirements. Although it is usually believed that "the role of medical physicists in Diagnostic Radiology is QC", this, not only limits the contribution of medical physicists, but is also no longer adequate to meet the needs of Diagnostic Radiology in terms of Quality. In order to assure quality practices more organized activities and efforts are required in the modern era of diagnostic radiology. The complete system of QC is just one element of a comprehensive quality assurance (QA) program that aims at ensuring that the requirements of quality of a product or service will consistently be fulfilled. A comprehensive Quality system, starts even before the procurement of any equipment, as the need analysis and the development of specifications are important components under the QA framework. Further expanding this framework of QA, a comprehensive Quality Management System can provide additional benefits to a Diagnostic Radiology service. Harmonized policies and procedures and elements such as mission statement or job descriptions can provide clarity and consistency in the services provided, enhancing the outcome and representing a solid platform for quality improvement. The International Atomic Energy Agency (IAEA) promotes this comprehensive quality approach in diagnostic imaging and especially supports the field of comprehensive clinical audits as a tool for quality improvement. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  6. Clinical application of the five-factor model.

    Science.gov (United States)

    Widiger, Thomas A; Presnall, Jennifer Ruth

    2013-12-01

    The Five-Factor Model (FFM) has become the predominant dimensional model of general personality structure. The purpose of this paper is to suggest a clinical application. A substantial body of research indicates that the personality disorders included within the American Psychiatric Association's (APA) Diagnostic and Statistical Manual of Mental Disorders (DSM) can be understood as extreme and/or maladaptive variants of the FFM (the acronym "DSM" refers to any particular edition of the APA DSM). In addition, the current proposal for the forthcoming fifth edition of the DSM (i.e., DSM-5) is shifting closely toward an FFM dimensional trait model of personality disorder. Advantages of this shifting conceptualization are discussed, including treatment planning. © 2012 Wiley Periodicals, Inc.

  7. Medical beam monitor—Pre-clinical evaluation and future applications

    Science.gov (United States)

    Frais-Kölbl, Helmut; Griesmayer, Erich; Schreiner, Thomas; Georg, Dietmar; Pernegger, Heinz

    2007-10-01

    Future medical ion beam applications for cancer therapy which are based on scanning technology will require advanced beam diagnostics equipment. For a precise analysis of beam parameters we want to resolve time structures in the range of microseconds to nanoseconds. A prototype of an advanced beam monitor was developed by the University of Applied Sciences Wiener Neustadt and its research subsidiary Fotec in co-operation with CERN RD42, Ohio State University and the Jožef Stefan Institute in Ljubljana. The detector is based on polycrystalline Chemical Vapor Deposition (pCVD) diamond substrates and is equipped with readout electronics up to 2 GHz analog bandwidth. In this paper we present the design of the pCVD-detector system and results of tests performed in various particle accelerator based facilities. Measurements performed in clinical high energy photon beams agreed within 1.2% with results obtained by standard ionization chambers.

  8. Medical beam monitor—Pre-clinical evaluation and future applications

    CERN Document Server

    Frais-Kölbl, H; Schreiner, T; Georg, D; Pernegger, H

    2007-01-01

    Future medical ion beam applications for cancer therapy which are based on scanning technology will require advanced beam diagnostics equipment. For a precise analysis of beam parameters we want to resolve time structures in the range of microseconds to nanoseconds. A prototype of an advanced beam monitor was developed by the University of Applied Sciences Wiener Neustadt and its research subsidiary Fotec in co-operation with CERN RD42, Ohio State University and the Jožef Stefan Institute in Ljubljana. The detector is based on polycrystalline Chemical Vapor Deposition (pCVD) diamond substrates and is equipped with readout electronics up to 2 GHz analog bandwidth. In this paper we present the design of the pCVD-detector system and results of tests performed in various particle accelerator based facilities. Measurements performed in clinical high energy photon beams agreed within 1.2% with results obtained by standard ionization chambers.

  9. Epigenetics and allergy: from basic mechanisms to clinical applications.

    Science.gov (United States)

    Potaczek, Daniel P; Harb, Hani; Michel, Sven; Alhamwe, Bilal Alashkar; Renz, Harald; Tost, Jörg

    2017-04-01

    Allergic diseases are on the rise in the Western world and well-known allergy-protecting and -driving factors such as microbial and dietary exposure, pollution and smoking mediate their influence through alterations of the epigenetic landscape. Here, we review key facts on the involvement of epigenetic modifications in allergic diseases and summarize and critically evaluate the lessons learned from epigenome-wide association studies. We show the potential of epigenetic changes for various clinical applications: as diagnostic tools, to assess tolerance following immunotherapy or possibly predict the success of therapy at an early time point. Furthermore, new technological advances such as epigenome editing and DNAzymes will allow targeted alterations of the epigenome in the future and provide novel therapeutic tools.

  10. Application of advanced diagnostics to airblast injector flows

    Science.gov (United States)

    Mcvey, John B.; Kennedy, Jan B.; Russell, Sid

    1987-01-01

    This effort is concerned with the application of both conventional laser velocimetry and phase Doppler anemometry to the flow produced by an airblast nozzle. The emphasis is placed on the acquisition of data using actual engine injector/swirler components at (noncombusting) conditions simulating those encountered in the engine. The objective of the effort was to test the applicability of the instrumentation to real injector flows, to develop information on the behavior of injectors at high flow, and to provide data useful in the development of physical models of injector flows.

  11. Nuclear physics applications in diagnostics and cancer therapy

    CERN Document Server

    Amaldi, Ugo

    2005-01-01

    Only 1% of the 18,000 world accelerators are devoted to the production of radioisotopes for medical diagnostics. In fact at present about 85% of all the medical examinations use /sup 99m/Tc produced in nuclear reactors. But the development of Positron Emission Tomography and of its combination with Computer Tomography will boost the hospital use of cyclotrons. Much more general is the use of electron linacs in cancer therapy about 40% of the world accelerators are used for this so called "conventional" radiotherapy. In the developed countries every 10 million inhabitants about 20,000 oncological patients are irradiated every year with high-energy photons (called X-rays by radiotherapists) produced by electron linacs. Much less used is "hadrontherapy", the radiotherapy technique that employs protons, neutrons or carbon ions. Protons and ions are 'heavy' charged particles: they assure a more 'conformal' treatment than X-rays and thus spare better the surrounding healthy tissues allowing a larger dose and thus a...

  12. Application of the Monte Carlo method to diagnostic radiology

    International Nuclear Information System (INIS)

    Persliden, J.

    1986-01-01

    A Monte Carlo program for photon transport is developed. The program is used to investigate the energy imparted to water slabs (simulating patients), and the related backscattered and transmitted energies as functions of primary photon energy and water slab thickness. The accuracy of the results depends on the cross-section data for the probabilities of the various interactions in the slab and on the physical quantity calculated. Backscattered energy fractions can vary by as much as 10-20 %, using different sets of published data for the photoelectric cross section while imparted fractions are only slightly affected. The results are used to calculate improved conversion factors for determining the energy imparted to the patient in X-ray diagnostic examinations from measurements of the air collision kerma integrated over beam area. The small angle distribution of scattered photons transmitted through a water slab, relevant to problems of image quality, is calculated taking into account the diffraction phenomena of liquid water. The calculations are performed with a collision density estimator. This estimator makes it possible to calculate important physical quantities which are virtually impracticable to assess with the Monte Carlo codes commonly used in medical physics or in experiments. With the collision density estimator, the influence of air gaps on the reduction of scattered radiation is investigated for different detectors, field areas and primary X-ray spectra. Contrast degradation and contrast improvement factors are given as functions of field area for various air gaps. (With 105 refs.) (author)

  13. Nuclear reaction data for IBA applications to cultural heritage diagnostics

    International Nuclear Information System (INIS)

    Maino, G.; Menapace, E.

    2008-01-01

    Main aspects are discussed concerning nuclear reaction cross-sections for PIXE and PIGE (Particle Induced Gamma-ray Emission) analyses, especially referring to cultural heritage diagnostics, within the framework of ion beam analysis (IBA) methods, also reviewing recent results from international Conferences on Nuclear Data for Science and Technology and from NEANSC meetings and IAEA initiatives on the matter.To sum up this work, it is then worth remarking the following items: IBA techniques are powerful tools to derive unique information as for corrosion, degradation and, generally, conservation conditions of materials. Careful analyses of specific systems require accurate evaluations and establishment of complete databases, in particular for stopping powers and relevant cross sections. The physical parameters to be accurately determined are, therefore, nuclear reaction cross sections of importance for NRA analysis of light elements and stopping powers and ranges of light and heavy ions in various matrices. Light elements (H, Li, B, C, N, O, etc.) play an important role as constituents of many important organic as well inorganic materials in historical and artistic objects. To a large extent these materials occur in the near-surface area of a material with altered or degraded composition

  14. Nuclear reaction data for IBA applications to cultural heritage diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Maino, G.; Menapace, E. [Bologna Univ., ENEA (Italy)

    2008-07-01

    Main aspects are discussed concerning nuclear reaction cross-sections for PIXE and PIGE (Particle Induced Gamma-ray Emission) analyses, especially referring to cultural heritage diagnostics, within the framework of ion beam analysis (IBA) methods, also reviewing recent results from international Conferences on Nuclear Data for Science and Technology and from NEANSC meetings and IAEA initiatives on the matter.To sum up this work, it is then worth remarking the following items: IBA techniques are powerful tools to derive unique information as for corrosion, degradation and, generally, conservation conditions of materials. Careful analyses of specific systems require accurate evaluations and establishment of complete databases, in particular for stopping powers and relevant cross sections. The physical parameters to be accurately determined are, therefore, nuclear reaction cross sections of importance for NRA analysis of light elements and stopping powers and ranges of light and heavy ions in various matrices. Light elements (H, Li, B, C, N, O, etc.) play an important role as constituents of many important organic as well inorganic materials in historical and artistic objects. To a large extent these materials occur in the near-surface area of a material with altered or degraded composition.

  15. The frequency of peritoneal tuberculosis using diagnostic laparoscopy in clinically suspected cases

    International Nuclear Information System (INIS)

    Sattar, Z.; Iqbal, M.

    2014-01-01

    Introduction: Diagnostic laparoscopy allows the visual examination and documentation of intra-abdominal organs in order to detect any pathology. It is an important tool for final minimally invasive exploration of patients with abdominal tuberculosis, the diagnosis of which remains uncertain despite employing the requisite laboratory and non-invasive imaging investigations. Objective: To determine the frequency of peritoneal tuberculosis using diagnostic laparoscopy in clinically suspected cases of peritoneal tuberculosis. Study Design: Cross sectional survey. Setting: The study was conducted in all the four Surgical Wards on surgical floor of Mayo Hospital Lahore. Duration of Study with Dates: Six months (1st July 2009 to 31st December 2009). Material and Methods: 35 Patients aged between 13-60 years with clinical suspicion of peritoneal tuberculosis were selected. The patients underwent the procedure accordingly. Per operative diagnosis of peritoneal tuberculosis made on the basis of presence of any or all of the operative (laparoscopic) findings such as multiple peritoneal adhesions, fibrous bands, whitish peritoneal tubercles, omental thickening and ascites. Diagnosis was confirmed with histopathology of peritoneal tissue biopsy. Also the biochemical analysis and culture sensitivity of ascetic fluid was routinely performed if any ascites is present. Results: Out of 35 patients, 40% were males and 60% females with mean age of 24.91+-6.69 years. The Laparoscopic findings of peritoneal tuberculosis were whitish peritoneal tubercles (57.2%) peritoneal adhesions (28.6%), ascites (17.2%), omental thickening (14.3%), fibrous bands (11.4%) and swollen edematous appendix (5.7%). Eighty percent were labeled with diagnosis of peritoneal tuberculosis on basis of diagnostic laparoscopy. These patients were confirmed to have peritoneal tuberculosis on histopathology of tissue biopsy. Conclusion: Diagnostic laparoscopy is useful in patients with suspected peritoneal

  16. Are CSF Biomarkers Useful as Prognostic Indicators in Diagnostically Unresolved Cognitively Impaired Patients in a Normal Clinical Setting

    DEFF Research Database (Denmark)

    Nielsen, Malene Schjønning; Simonsen, Anja Hviid; Siersma, Volkert

    2016-01-01

    in diagnostically unresolved patients. METHODS: Data on 348 patients were retrospectively evaluated. All participants had a standardized diagnostic workup and follow-up in a memory clinic. RESULTS: Aβ42 levels and Aβ42/p-tau ratios were reduced and levels of t-tau and p-tau as well as the t-tau × p-tau/Aβ42 ratio...

  17. The Diagnostic Accuracy of Clinical and External Pelvimetry in Prediction of Dystocia in Nulliparous Women

    Directory of Open Access Journals (Sweden)

    R Alijahan

    2011-08-01

    Full Text Available Introduction: Clinical pelvimetry is very uncomfortable for the patient and is associated with subjective error, while external pelvimetry is a simple and acceptable method for patients. The objective of this study was to compare the diagnostic accuracy of clinical and external pelvimetry in prediction of dystocia in nulliparous women. Methods: In this study between December 2008 and January 2009, 447 nulliparous women with a single pregnancy in vertex presentation and gestational age 38-42 weeks referring to the Ommolbanin hospital of Mashhad were included. External pelvic dimensions were assessed at the time of admission and clinical pelvimetry was performed by another examiner. These measurements were not available to the clinician in charge of the delivery. Dystocia was defined as caesarean section and vacuum or forceps delivery for abnormal progress of labor ( active uterine contractions, arrest of cervical dilatation or cervical dilatation less than 1 cm /h in the active phase for 2 hours, prolongation of second stage beyond 2 hours or fetal head descent less than 1cm/h. Statistical tests included Fisher exact test and Chi- square test. Results: The highest sensitivity obtained from clinical pelvimetry was 33.3% and related to diagonal conjugate less than 11.5 cm. The sensitivity of external pelvic dimensions was higher than clinical pelvimetry that was highest for the Michaelis transverse diameter(60.72%. Conclusion: External pelvimetry in comparison to clinical pelvimetry is a better method for identifying dystocia in nulliparous women and can replace clinical pelvimetry in antenatal care programs.

  18. Neurobrucellosis: clinical, diagnostic, therapeutic features and outcome. Unusual clinical presentations in an endemic region

    Directory of Open Access Journals (Sweden)

    Nurgul Ceran

    Full Text Available Brucellosis is a zoonotic infection and has endemic characteristics. Neurobrucellosis is an uncommon complication of this infection. The aim of this study was to present unusual clinical manifestations and to discuss the management and outcome of a series of 18 neurobrucellosis cases. Initial clinical manifestations consist of pseudotumor cerebri in one case, white matter lesions and demyelinating syndrome in three cases, intracranial granuloma in one case, transverse myelitis in two cases, sagittal sinus thrombosis in one case, spinal arachnoiditis in one case, intracranial vasculitis in one case, in addition to meningitis in all cases. Eleven patients were male and seven were female. The most prevalent symptoms were headache (83% and fever (44%. All patients were treated with rifampicin, doxycycline plus trimethoprim-sulfamethoxazole or ceftriaxone. Duration of treatment (varied 3-12 months was determined on basis of the CSF response. In four patients presented with left mild sequelae including aphasia, hearing loss, hemiparesis. In conclusion, although mortality is rare in neurobrucellosis, its sequelae are significant. In neurobrucellosis various clinical and neuroradiologic signs and symptoms can be confused with other neurologic diseases. In inhabitants or visitors of endemic areas, neurobrucellosis should be kept in mind in cases that have unusual neurological manifestations.

  19. Applications of 'edge-on' illuminated porous plate detectors for diagnostic X-ray imaging

    CERN Document Server

    Shikhaliev, P M

    2002-01-01

    Scanning X-ray imaging systems for non-invasive diagnostics have several advantages over conventional imaging systems using area detectors. They significantly reduce the detected scatter radiation, cover large areas and potentially provide high spatial resolution. Applications of one-dimensional gaseous detectors and 'edge-on' illuminated silicon strip detectors for scanning imaging systems are currently under intensive investigation. The purpose of this work is to investigate 'edge-on' illuminated Porous Plate (PP) detectors for applications in diagnostic X-ray imaging. MicroChannel Plate (MCP), which is a common type of PP, has previously been investigated as a detector in surface-on illumination mode for medical X-ray imaging. However, its detection efficiency was too low for medical imaging applications. In the present study, the PP are used in the 'edge-on' illumination mode. Furthermore, the structural parameters of different PP types are optimized to improve the detection efficiency in the diagnostic X...

  20. Possibility of clinical applications of forest medicine.

    Science.gov (United States)

    Li, Qing; Kawada, Tomoyuki

    2014-01-01

    Since 2004, we have conducted a series of studies of the effect of forest therapy on human health and established forest therapy as a new preventive strategy. We have found that forest therapy has many beneficial effects on human health. However, there is almost no study dealing with the possibility of clinical applications of forest therapy. In this review, we discuss the possibility of clinical applications of forest therapy from the following viewpoints: 1. Forest therapy can decrease blood pressure, heart rate, sympathetic nerve activity, and levels of stress hormones, such as urinary adrenaline and noradrenaline, and can increase parasympathetic nerve activity, suggesting its preventive effect on hypertension. 2. Forest therapy can also decreace the scores for anxiety, depression, anger, fatigue, and confusion and increase the score for vigor in the Profile of Mood States (POMS) test, suggesting its preventive effect on mental depression. 3. Forest therapy can increase the activity and number of human natural killer (NK) cells and the intracellular levels of anticancer proteins, suggesting its preventive effect on cancers. 4. These findings suggest that forest therapy may have preventive effects on lifestyle-related diseases. However, the above preventive effects of forest therapy should be confirmed in clinical research.

  1. Using recruitment source timing and diagnosticity to enhance applicants' occupation-specific human capital.

    Science.gov (United States)

    Campion, Michael C; Ployhart, Robert E; Campion, Michael A

    2017-05-01

    [Correction Notice: An Erratum for this article was reported in Vol 102(5) of Journal of Applied Psychology (see record 2017-14296-001). In the article, the following headings were inadvertently set at the wrong level: Method, Participants and Procedure, Measures, Occupation specific human capital, Symbolic jobs, Relevant majors, Occupation-specific capital hotspots, Source timing, Source diagnosticity, Results, and Discussion. All versions of this article have been corrected.] This study proposes that reaching applicants through more diagnostic recruitment sources earlier in their educational development (e.g., in high school) can lead them to invest more in their occupation-specific human capital (OSHC), thereby making them higher quality candidates. Using a sample of 78,157 applicants applying for jobs within a desirable professional occupation in the public sector, results indicate that applicants who report hearing about the occupation earlier, and applicants who report hearing about the occupation through more diagnostic sources, have higher levels of OSHC upon application. Additionally, source timing and diagnosticity affect the likelihood of candidates applying for jobs symbolic of the occupation, selecting relevant majors, and attending educational institutions with top programs related to the occupation. These findings suggest a firm's recruiting efforts may influence applicants' OSHC investment strategies. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  2. How does additional diagnostic testing influence the initial diagnosis in patients with cognitive complaints in a memory clinic setting?

    NARCIS (Netherlands)

    Meijs, A.P.; Claassen, J.A.H.R.; Olde Rikkert, M.G.M.; Schalk, B.W.M; Meulenbroek, O.V.; Kessels, R.P.C.; Melis, R.J.F.

    2015-01-01

    Background: patients suspected of dementia frequently undergo additional diagnostic testing (e.g. brain imaging or neuropsychological assessment) after standard clinical assessment at a memory clinic. This study investigates the use of additional testing in an academic outpatient memory clinic and

  3. How does additional diagnostic testing influence the initial diagnosis in patients with cognitive complaints in a memory clinic setting?

    NARCIS (Netherlands)

    Meijs, A.P.; Claassen, J.A.; Olde Rikkert, M.G.M.; Schalk, B.W.M; Meulenbroek, O.V.; Kessels, R.P.C.; Melis, R.J.F.

    2015-01-01

    BACKGROUND: patients suspected of dementia frequently undergo additional diagnostic testing (e.g. brain imaging or neuropsychological assessment) after standard clinical assessment at a memory clinic. This study investigates the use of additional testing in an academic outpatient memory clinic and

  4. Analytical applications of MIPs in diagnostic assays: future perspectives.

    Science.gov (United States)

    Bedwell, Thomas S; Whitcombe, Michael J

    2016-03-01

    Many efforts have been made to produce artificial materials with biomimetic properties for applications in binding assays. Among these efforts, the technique of molecular imprinting has received much attention because of the high selectivity obtainable for molecules of interest, robustness of the produced polymers, simple and short synthesis, and excellent cost efficiency. In this review, progress in the field of molecularly imprinted sorbent assays is discussed-with a focus on work conducted from 2005 to date.

  5. Telepsychiatry clinical decision support system used by non-psychiatrists in remote areas: Validity & reliabilityof diagnostic module

    Directory of Open Access Journals (Sweden)

    Savita Malhotra

    2017-01-01

    Interpretation & conclusions: Diagnostic tool showed acceptable to good validity and reliability when used by non-specialists at remote sites. Our findings show that diagnostic tool of the telepsychiatry application has potential to empower non-psychiatrist doctors and paramedics to diagnose psychiatric disorders accurately and reliably in remote sites.

  6. panelcn.MOPS: Copy-number detection in targeted NGS panel data for clinical diagnostics.

    Science.gov (United States)

    Povysil, Gundula; Tzika, Antigoni; Vogt, Julia; Haunschmid, Verena; Messiaen, Ludwine; Zschocke, Johannes; Klambauer, Günter; Hochreiter, Sepp; Wimmer, Katharina

    2017-07-01

    Targeted next-generation-sequencing (NGS) panels have largely replaced Sanger sequencing in clinical diagnostics. They allow for the detection of copy-number variations (CNVs) in addition to single-nucleotide variants and small insertions/deletions. However, existing computational CNV detection methods have shortcomings regarding accuracy, quality control (QC), incidental findings, and user-friendliness. We developed panelcn.MOPS, a novel pipeline for detecting CNVs in targeted NGS panel data. Using data from 180 samples, we compared panelcn.MOPS with five state-of-the-art methods. With panelcn.MOPS leading the field, most methods achieved comparably high accuracy. panelcn.MOPS reliably detected CNVs ranging in size from part of a region of interest (ROI), to whole genes, which may comprise all ROIs investigated in a given sample. The latter is enabled by analyzing reads from all ROIs of the panel, but presenting results exclusively for user-selected genes, thus avoiding incidental findings. Additionally, panelcn.MOPS offers QC criteria not only for samples, but also for individual ROIs within a sample, which increases the confidence in called CNVs. panelcn.MOPS is freely available both as R package and standalone software with graphical user interface that is easy to use for clinical geneticists without any programming experience. panelcn.MOPS combines high sensitivity and specificity with user-friendliness rendering it highly suitable for routine clinical diagnostics. © 2017 The Authors. Human Mutation published by Wiley Periodicals, Inc.

  7. Gilbert’s syndrome: clinical features, diagnostics, differential diagnosis and treatment (part 2

    Directory of Open Access Journals (Sweden)

    T.V. Sorokman

    2017-02-01

    Full Text Available We searched for published and unpublished research using PubMed as the search engine by the keywords: “Gilbert’s syndrome”, “clinical manifestation”, “diagnosis”, “treatment”, taking into consideration studies conducted in the last 10 years, citation review of relevant primary and review articles, conference abstracts, personal files, and contact with expert informants. The criterion for the selection of articles for the study was based on their close relevance to the topic, thus, out of 75 analyzed articles, the findings of the researches covered in 28 articles were crucial. Clinical manifestations of Gilbert’s syndrome (GS are possible both in homozygous for UGT1A1, and in heterozygous status. A latent variant of the disease prevails in individuals with heterozygous status. Up to 30 % of homozygous for the defective gene of GS individuals have an asymptomatic course of the disease. Clinical types of GS: dyspeptic — 43.2 %, asthenovegetative — 15.9 %, icteric — 14.8 % and asymptomatic — 26.1 %. Dietary deviations, mental fatigue, stress, trauma, acute infections, including hepatitis, certain medications intake are the triggers for GS. In 86.4 % of children with GS, the pathology of the upper digestive tract was detected: duodenitis — in 58 % of cases, gastritis — in 56.8 %, esophagitis — in 12.5 %, duodenal ulcer — in 2.3 %, in 39.7 % of patients sphincter disorders were registered (duodenogastric and gastroesophageal bile reflux. The GS is characterized by reduced detoxification function of the liver, in particular in 2/3 of patients decreased hepatocyte metabolic activity was observed, the excretory function of liver cell suffers in another half of patients, the biliary tract disorders and increased risk of gallstones formation are described in 88 % of cases. Some patients with GS have certain psychological disorders, including anxiety. Diagnostic criteria for GS: 1. A peculiar pale yellowish

  8. Clinical, diagnostic and therapeutic management of patients with breast tuberculosis: Analysis of 46 Cases

    Directory of Open Access Journals (Sweden)

    Murat Ozgur Kilic

    2016-01-01

    Full Text Available Breast tuberculosis is a rare form of extrapulmonary tubercular infection. Our aim is to highlight the nonspecific clinical presentations, diagnostic difficulties and therapeutic approaches of mammarian tuberculosis. Forty-six patients diagnosed with breast tuberculosis between 2005 and 2015 were reviewed retrospectively. Clinical features, all diagnostic methods, and the outcomes of treatment were analysed. All cases were female with a mean age of 36.4 years. Breast mass and pain were the most common complaints. While 34.8% of the cases had a physical examination with suspicions for malignancy, 43.5% of the patients had Breast Imaging Reporting and Data System (BI-RADS 4 or 5 lesions suggested malignancy radiologically. Definitive diagnosis was based on histopathologic examination through core needle biopsy (n = 29, excisional biopsy (n = 12, and open biopsy (n = 5 taken from the abscess wall during drainage. Standard antiTB therapy for 6 months was given to all cases. Thirty-three patients recovered with standard 6-month therapy while extended treatment for 9–12 months was needed in 13 (28.2% cases. Surgery was carried out in 17 cases. Two patients developed recurrence. Breast tuberculosis can be easily confused with breast cancer, suppurative abscess, and other causes of granulomatous mastitis, both clinically and radiologically. A multidisciplinary approach is required to prevent diagnostic delays and unnecessary surgical interventions. Although antiTB therapy is the mainstay treatment of breast TB, surgery is usually indicated in patients refractory to medical treatment.

  9. CLINICAL MANIFESTATION, DIAGNOSTICS AND TREATMENT OF KAWASAKI DISEASE: KNOWN DATA AND UNSOLVED QUESTIONS

    Directory of Open Access Journals (Sweden)

    G. А. Lyskina

    2013-01-01

    Full Text Available The lecture deals with the most common systemic vasculitis in pediatric practice — Kawasaki disease. This disorder is associated with risk of myocardial infarction and sudden cardiac death in children and young adults and at present is considered to be the main cause of the acquired heard diseases in children. The authors give historical aspects and modern opinions on etiology, pathogenesis, clinical manifestation, diagnostics and treatment of Kawasaki disease. The data were summarized from Russian and foreign literature as well as from the own authors’ experience.

  10. Clinical findings and diagnostic imaging of small intestinal rupture due to blunt abdominal trauma

    International Nuclear Information System (INIS)

    Takahashi, Hitoshi; Sakata, Ikuhiro; Ogawa, Masaaki; Izumoto, Gentaro; Kim, Akio; Maeda, Shigenari; Yasutomi, Masayuki; Yamamoto, Toshio

    1987-01-01

    Eight patients with small intestinal rupture due to blunt abdominal trauma were analyzed by their clinical findings and diagnostic imaging (plain film, ultrasound and computed tomography). Computed tomography was most useful for identification of intraabdominal extraluminal free air (pneumoperitoneum) and this finding was obtained in seven out of the eight patients (87.5 %). Intraabdominal fluid collection was observed in All the patients and was most clearly detectable by ultrasound and computed tomography. These examinations may be applied to identification of properties of the fluid collection. All the patients eventually developed peritonitis when laparotomy was decided. Thus, close follow up observation of abdominal physical signs was also of critical importance. (author)

  11. Malignant otitis externa: Variability of clinical course and difficulties of diagnostics

    Directory of Open Access Journals (Sweden)

    Janićijević Miloš

    2014-01-01

    Full Text Available This paper shows the case of a 70-year-old diabetic patient who was admitted to the ORL and MFS clinic as an emergency case with the right ear otalgia, in the right mastoid extension, facialis paralysis and the right ear suppuration all of which lasted for a month before the hospitalization. On admission, the initial diagnostics stated canal skin edema of the external hearing canal which made the eardrum impossible to visualize. Granulations at the bottom of the canal were visible. During the admission, the patient was submitted to conservative and surgical treatments which confirmed that it was the case of malignant otitis externa.

  12. NanoString, a novel digital color-coded barcode technology: current and future applications in molecular diagnostics.

    Science.gov (United States)

    Tsang, Hin-Fung; Xue, Vivian Weiwen; Koh, Su-Pin; Chiu, Ya-Ming; Ng, Lawrence Po-Wah; Wong, Sze-Chuen Cesar

    2017-01-01

    Formalin-fixed, paraffin-embedded (FFPE) tissue sample is a gold mine of resources for molecular diagnosis and retrospective clinical studies. Although molecular technologies have expanded the range of mutations identified in FFPE samples, the applications of existing technologies are limited by the low nucleic acids yield and poor extraction quality. As a result, the routine clinical applications of molecular diagnosis using FFPE samples has been associated with many practical challenges. NanoString technologies utilize a novel digital color-coded barcode technology based on direct multiplexed measurement of gene expression and offer high levels of precision and sensitivity. Each color-coded barcode is attached to a single target-specific probe corresponding to a single gene which can be individually counted without amplification. Therefore, NanoString is especially useful for measuring gene expression in degraded clinical specimens. Areas covered: This article describes the applications of NanoString technologies in molecular diagnostics and challenges associated with its applications and the future development. Expert commentary: Although NanoString technology is still in the early stages of clinical use, it is expected that NanoString-based cancer expression panels would play more important roles in the future in classifying cancer patients and in predicting the response to therapy for better personal therapeutic care.

  13. Clinical Applications of Reverse Panoramic Radiography

    Directory of Open Access Journals (Sweden)

    Sujatha S Reddy

    2011-09-01

    Full Text Available The essence of oral and maxil-lofacial radiology is not only to be an important tool in the diagnostic assessment of dental patients but also to equip the clinician with the ability to interpret images of certain maxillocraniofacial structures of importance to dental, medical and surgical practices. Although combinations of several conven-tional x-ray projections can be adequate in a number of clinical situations, radiographic assessment of certain craniofacial structures some-times needs to be facilitated by other imaging modalities. A not-so-recent development called reverse panoramic radiography may be a useful adjuvant to such a situation, at least in the near future. It is essentially a technique where the patient is placed backwards in the panoramic machine in a reverse position in such a way that x-ray beam is directed through the patient’s face and the exit beam then passes through the patient’s head on the opposite side where it is captured on the receptor. The following manuscript is an attempt to throw light on this technique and the impact it may have on dental, medical and surgical practices. The advantages and disadvantages of reverse panoramic radiography and it’s comparison to conventional panoramic radiographs and other skull views are also dis-cussed.

  14. Clinical application of cerebral dynamic perfusion studies

    International Nuclear Information System (INIS)

    DeLand, F.H.

    1975-01-01

    Radionuclide cerebral perfusion studies are assuming a far greater importance in the detection and differential diagnosis of cerebral lesions. Perfusion studies not only contribute to the differential diagnosis of lesions but in certain cases are the preferred methods by which more accurate clinical interpretations can be made. The characteristic blood flow of arterio-venous malformations readily differentiates this lesion from neoplasms. The decreased perfusion or absent perfusion observed in cerebral infarctions is diagnostic without concurrent evidence from static images. Changes in rates and direction of blood flow contribute fundamental information to the status of stenosis and vascular occlusion and, in addition, offer valuable information on the competency and routes of collateral circulation. The degree of cerebral perfusion after cerebral vascular accidents appears to be directly related to patient recovery, particularly muscular function. Cerebral perfusion adds a new parameter in the diagnosis of subdural haematomas and concussion and in the differentiation of obscuring radioactivity from superficial trauma. Although pictorial displays of perfusion blood flow will offer information in most cerebral vascular problems, the addition of computer analysis better defines temporal relationships of regional blood flow, quantitative changes in flow and the detection of the more subtle increases or decreases in cerebral blood flow. The status of radionuclide cerebral perfusion studies has taken on an importance making it the primary modality for the diagnosis of cerebral lesions. (author)

  15. Clinical application of helical CT colonography

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Rujian; Liang Jianhao; Ou Weiqian; Wen Haomao

    2009-01-01

    Objective: To investigate the clinical value of 16-slice helical CT colonography in the diagnosis of colon tumor and polypus. Methods: 16-slice helical CT volumetric scanning was performed in 18 patients with colonic disease, including colonic tumor (n=16) and colonic polypus (n=2). 3D images, virtual endoscopy and multiplanar reformation were obtained in the AW4.1 workstation. CT appearances were compared with operation and fiberoptic colonoscopy. Results: Satisfied results were achieved from 18 patients, no difference found in results between CT colonography and operation in 16 patients with colonic tumor. Conclusion: 16-slice helical CT colonography is of great value in preoperative staging of colonic tumor and have a high value in clinical application. (authors)

  16. Clinical applications of cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Marcu, C.B.; Beek, A.M.; Van Rossum, A.C.

    2006-01-01

    Cardiovascular magnetic resonance imaging (MRI) has evolved from an effective research tool into a clinically proven, safe and comprehensive imaging modality. It provides anatomic and functional information in acquired and congenital heart disease and is the most precise technique for quantification of ventricular volumes, function and mass. Owing to its excellent interstudy reproducibility, cardiovascular MRI is the optimal method for assessment of changes in ventricular parameters after therapeutic intervention. Delayed contrast enhancement is an accurate and robust method used in the diagnosis of ischemic and nonischemic cardiomyopathies and less common diseases, such as cardiac sarcoidosis and myocarditis. First-pass magnetic contrast myocardial perfusion is becoming an alternative to radionuclide techniques for the detection of coronary atherosclerotic disease. In this review we outline the techniques used in cardiovascular MRI and discuss the most common clinical applications. (author)

  17. Bioethics of Clinical Applications of Stem Cells.

    Science.gov (United States)

    Petrini, Carlo

    2017-04-12

    The clinical applications of stem cells pose a multitude of problems, including safety, efficacy, information and consent, the right to unproven treatments, the "right to try", costs, access, sustainability, scientific scrupulousness, patents and regulatory aspects, to name but a few. This article does not address individual issues, but rather introduces and discusses some of the possible approaches to solving the problems. The first part compares the consequentialist and deontological approaches, offering an overview of "top-down" and "bottom-up" models and proposing the principles of personalism as applied in clinical settings. The second part of the article suggests practical frameworks for organising the ethical issues, focusing in particular on the medical indications, patient preferences, quality of life, and contextual features.

  18. Clinical applications of bovine colostrum therapy

    DEFF Research Database (Denmark)

    Rathe, Mathias; Müller, Klaus; Sangild, Per Torp

    2014-01-01

    Bovine colostrum, the first milk that cows produce after parturition, contains high levels of growth factors and immunomodulatory components. Some healthy and diseased individuals may gain health benefits by consuming bovine colostrum as a food supplement. This review provides a systematic...... to populations, outcomes, and methodological quality, as judged by the Jadad assessment tool. Many studies used surrogate markers to study the effects of bovine colostrum. Studies suggesting clinical benefits of colostrum supplementation were generally of poor methodological quality, and results could...... not be confirmed by other investigators. Bovine colostrum may provide gastrointestinal and immunological benefits, but further studies are required before recommendations can be made for clinical application. Animal models may help researchers to better understand the mechanisms of bovine colostrum supplementation...

  19. Clinical application of radiotherapy combined with chemotherapy

    International Nuclear Information System (INIS)

    Morita, Kozo

    1978-01-01

    In clinical application of radiation therapy combined with chemotherapy, it is important to gain the maximal therapeutic benefit. At present we have no agents that improve the therapeutic ratio by enhancing the effect of radiation on the tumor cell selectively. Therefore, it is necessary to use combining some or all of following procedures: (1) the intraarterial infusion of the agents, (2) the selective localization by reason of the biological affinity of the agents, (3) the surgical removal of the non-sensitized tumor residue and (4) the selective sensitization of the tumor due to its shorter cell cycle. (author)

  20. Prostate specific antigen and its clinical application

    International Nuclear Information System (INIS)

    Xu Yang

    2000-01-01

    Prostate-Specific Antigen (PSA), a serine proteases, is a glycoprotein consisting of a single polypeptide chain. Secreted exclusively by epithelial cells of the prostate gland, PSA is found largely in seminal plasma. Only a small amount of PSA can be found in normal serum. Serum PSA levels are found to be, considerably increased in prostate cancer patients. A number of studies on PSA have made great achievement on its biochemistry, analytical method and clinical application. PSA as one of the most important tumor marker, is used to help diagnosis and monitor the therapeutic efficacy of prostate cancer

  1. A relaxation method with application in diagnostic radiology

    International Nuclear Information System (INIS)

    Herman, G.T.; Lent, A.H.

    1980-01-01

    Hildreth (1959) proposed an algorithm for optimizing positive definite quadratic forms subject to linear inequality constraints. Although Hildreth's original proof of the convergence of his procedure to a feasible vector optimizing the quadratic form was found to be not applicable to arbitrary inequality constraints sets, a general proof of convergence has recently been found. In this paper a way of substantially reducing the computer time and storage required by a Hildreth-type procedure when the inequality constraints have a special property is discussed. This property arises naturally in image reconstruction from projections. (Auth.)

  2. A clinical perspective on the 2016 WHO brain tumor classification and routine molecular diagnostics.

    Science.gov (United States)

    van den Bent, Martin J; Weller, Michael; Wen, Patrick Y; Kros, Johan M; Aldape, Ken; Chang, Susan

    2017-05-01

    The 2007 World Health Organization (WHO) classification of brain tumors did not use molecular abnormalities as diagnostic criteria. Studies have shown that genotyping allows a better prognostic classification of diffuse glioma with improved treatment selection. This has resulted in a major revision of the WHO classification, which is now for adult diffuse glioma centered around isocitrate dehydrogenase (IDH) and 1p/19q diagnostics. This revised classification is reviewed with a focus on adult brain tumors, and includes a recommendation of genes of which routine testing is clinically useful. Apart from assessment of IDH mutational status including sequencing of R132H-immunohistochemistry negative cases and testing for 1p/19q, several other markers can be considered for routine testing, including assessment of copy number alterations of chromosome 7 and 10 and of TERT promoter, BRAF, and H3F3A mutations. For "glioblastoma, IDH mutated" the term "astrocytoma grade IV" could be considered. It should be considered to treat IDH wild-type grades II and III diffuse glioma with polysomy of chromosome 7 and loss of 10q as glioblastoma. New developments must be more quickly translated into further revised diagnostic categories. Quality control and rapid integration of molecular findings into the final diagnosis and the communication of the final diagnosis to clinicians require systematic attention. © The Author(s) 2017. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Principles of dispensary observation of patients with Parkinson's disease in a specialized clinical diagnostic room

    Directory of Open Access Journals (Sweden)

    Krivonos О.V.

    2013-12-01

    Full Text Available Aim: to develop and implement of the order of the dispensary observation of Parkinson's disease patients. Material and methods, the dispensary observation of Parkinson's disease patients had been performed by neurologist and diagnostic room (CDR based on the outpatient department of health care institutions obeyed by FMBA of Russia in six Closed Administrative-Territorial Units: Seversk, Zarechniy, Ozersk, Lesnoy, Sarov and Zheleznogorsk. Neurologist examined of patients and put data to the Register's database. Register's database had 588 Parkinson's disease examined patients, 112 of them (19,1% had stage II of the disease by Hoehn and Yahr, 231 (39,3% patients — stage III by Hoehn and Yahr, 187 (31,8% patients — stage IV byHoehn and Yahr, 58 (9,9% patients — stage V by Hoehn and Yahr. The duration of the dispensary observation of Parkinson's disease patients was 4 years (2009-2012. Results. There are and implement the order of the observed and accounting of adult's group of Parkinson's disease patients were developed, who are registered in the clinical and diagnostic rooms, including the frequency of physician's visits, the list of diagnostic and treatment activities and efficiency endpoint of the dispensary observation. Conclusion. Implementation of the order of the dispensary observation according to the Register allowed to identify the main disabling PD's symptoms (depression, dementia, motor fluctuations and dyskinesia and timely correction of therapy.

  4. The clinical inadequacy of the DSM-5 classification of somatic symptom and related disorders: an alternative trans-diagnostic model.

    Science.gov (United States)

    Cosci, Fiammetta; Fava, Giovanni A

    2016-08-01

    The Diagnostic and Statistical of Mental Disorders, Fifth Edition (DSM-5) somatic symptom and related disorders chapter has a limited clinical utility. In addition to the problems that the single diagnostic rubrics and the deletion of the diagnosis of hypochondriasis entail, there are 2 major ambiguities: (1) the use of the term "somatic symptoms" reflects an ill-defined concept of somatization and (2) abnormal illness behavior is included in all diagnostic rubrics, but it is never conceptually defined. In the present review of the literature, we will attempt to approach the clinical issue from a different angle, by introducing the trans-diagnostic viewpoint of illness behavior and propose an alternative clinimetric classification system, based on the Diagnostic Criteria for Psychosomatic Research.

  5. State of malaria diagnostic testing at clinical laboratories in the United States, 2010: a nationwide survey

    Directory of Open Access Journals (Sweden)

    Abanyie Francisca A

    2011-11-01

    Full Text Available Abstract Background The diagnosis of malaria can be difficult in non-endemic areas, such as the United States, and delays in diagnosis and errors in treatment occur too often. Methods A nationwide survey of laboratories in the United States and its nine dependent territories was conducted in 2010 to determine factors that may contribute to shortcomings in the diagnosis of malaria. This survey explored the availability of malaria diagnostic tests, techniques used, and reporting practices. Results The survey was completed by 201 participants. Ninety percent reported that their laboratories had at least one type of malaria diagnostic test available on-site. Nearly all of the respondents' laboratories performed thick and thin smears on-site; approximately 50% had access to molecular testing; and only 17% had access to rapid diagnostic tests on-site. Seventy-three percent reported fewer than five confirmed cases of malaria in their laboratory during the 12-month period preceding the survey. Twenty-eight percent stated that results of species identification took more than 24 hours to report. Only five of 149 respondents that performed testing 24 hours a day, 7 days a week complied with all of the Clinical and Laboratory Standards Institute (CLSI guidelines for analysis and reporting of results. Conclusion Although malaria diagnostic testing services were available to a majority of U.S. laboratories surveyed, very few were in complete compliance with all of the CLSI guidelines for analysis and reporting of results, and most respondents reported very few cases of malaria annually. Laboratories' difficulty in adhering to the rigorous CLSI guidelines and their personnel's lack of practice and proficiency may account for delays and errors in diagnosis. It is recommended that laboratories that infrequently process samples for malaria seek opportunities for practice and proficiency training annually and take advantage of available resources to assist in

  6. The diagnostic value of component-resolved diagnostics in peanut allergy in children attending a Regional Paediatric Allergology Clinic.

    Science.gov (United States)

    van Veen, Leonieke N; Heron, Michiel; Batstra, Manou; van Haard, Paul M M; de Groot, Hans

    2016-06-02

    To date, diagnosing food allergies in children still presents a diagnostic dilemma, leading to uncertainty concerning the definite diagnosis of peanut allergy, as well as to the need for strict diets and the potential need for adrenalin auto-injectors. This uncertainty in particular is thought to contribute to a lower quality of life. In the diagnostic process double-blind food challenges are considered the gold standard, but they are time-consuming as well as potentially hazardous. Other diagnostic tests have been extensively studied and among these component-resolved diagnostics appeared to present a promising alternative: Ara h2, a peanut storage protein in previous studies showed to have a significant predictive value. Sixty-two out of 72 children, with suspected peanut allergy were analyzed using serum specific IgE and/or skin prick tests and specific IgE to several components of peanut (Ara h 1, 2, 3, 6, 8, 9). Subsequently, double-blind food challenges were performed. The correlation between the various diagnostic tests and the overall outcome of the double-blind food challenges were studied, in particular the severity of the reaction and the eliciting dose. The double-blind provocation with peanut was positive in 33 children (53 %). There was no relationship between the eliciting dose and the severity of the reaction. A statistically significant relationship was found between the skin prick test, specific IgE directed to peanut, Ara h 1, Ara h 2 or Ara h 6, and the outcome of the food challenge test, in terms of positive or negative (P food challenge. This study shows that component-resolved diagnostics is not superior to specific IgE to peanut extract or to skin prick testing. At present, it cannot replace double-blind placebo-controlled food challenges for determination of the eliciting dose or the severity of the peanut allergy in our patient group.

  7. Clinical application of multi-detector CT-guided percutaneous coaxial biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Jia Ningyang; Liu Shiyuan; Zhang Dianbo; Xiao Xiangsheng; Li Wentao; Li Chenzhou

    2008-01-01

    Objective: To evaluate the clinical application of multi-slice CT-guided percutaneous transthoracic lung coaxial-biopsy for pulmonary lesions. Methods: 152 times of 143 patients were performed with percutaneous transthoracic coaxial biopsy under multiple-slice CT-guidance. Analysis was carried out to investigate the diagnostic accuracy and the relationship between the size of the lesions for coaxial biopsy, together with the complications. Results: The diagnostic accuracy was 94.9% with specificity of 100%, including malignant tumors 116 cases (squamous cell cancer 48 cases, adenocarcinoma 34, small cell undifferentiated carcinoma 6, large cell carcinoma 4, bronchial alveolar carcinoma 8, metastatic carcinoma 16) and 19 cases of benign ones(TB 7 cases, inflammatory pseudotumor 9, hematoma 1, lung abscess 1). The size of lesion had a significant influence on the diagnostic accuracy. Conclusions: Percutaneous transthoracic coaxial lung biopsy is a safety method, possessing a high diagnostic accuracy. (authors)

  8. Development, diagnostic and applications of radio-frequency plasma reactor

    Science.gov (United States)

    Puac, N.

    2008-07-01

    In many areas of the industry, plasma processing of materials is a vital technology. Nonequilibrium plasmas proved to be able to produce chemically reactive species at a low gas temperature while maintaining highly uniform reaction rates over relatively large areas (Makabe and Petrovic 2006). At the same time nonequilibrium plasmas provide means for good and precise control of the properties of active particles that determine the surface modification. Plasma needle is one of the atmospheric pressure sources that can be used for treatment of the living matter which is highly sensitive when it comes to low pressure or high temperatures (above 40 C). Dependent on plasma conditions, several refined cell responses are induced in mammalian cells (Sladek et al. 2005). It appears that plasma treatment may find many biomedical applications. However, there are few data in the literature about plasma effects on plant cells and tissues. So far, only the effect of low pressure plasmas on seeds was investigated. It was shown that short duration pretreatments by non equilibrium low temperature air plasma were stimulative in light induced germination of Paulownia tomentosa seeds (Puac et al. 2005). As membranes of plants have different properties to those of animals and as they show a wide range of properties we have tried to survey some of the effects of typical plasma which is envisaged to be used in biotechnological applications on plant cells. In this paper we will make a comparison between two configurations of plasma needle that we have used in treatment of biological samples (Puac et al. 2006). Difference between these two configurations is in the additional copper ring that we have placed around glass tube at the tip of the needle. We will show some of the electrical characteristics of the plasma needle (with and without additional copper ring) and, also, plasma emission intensity obtained by using fast ICCD camera.

  9. Advancing the education in molecular diagnostics: the IFCC-Initiative "Clinical Molecular Biology Curriculum" (C-CMBC); a ten-year experience.

    Science.gov (United States)

    Lianidou, Evi; Ahmad-Nejad, Parviz; Ferreira-Gonzalez, Andrea; Izuhara, Kenji; Cremonesi, Laura; Schroeder, Maria-Eugenia; Richter, Karin; Ferrari, Maurizio; Neumaier, Michael

    2014-09-25

    Molecular techniques are becoming commonplace in the diagnostic laboratory. Their applications influence all major phases of laboratory medicine including predisposition/genetic risk, primary diagnosis, therapy stratification and prognosis. Readily available laboratory hardware and wetware (i.e. consumables and reagents) foster rapid dissemination to countries that are just establishing molecular testing programs. Appropriate skill levels extending beyond the technical procedure are required for analytical and diagnostic proficiency that is mandatory in molecular genetic testing. An international committee (C-CMBC) of the International Federation for Clinical Chemistry (IFCC) was established to disseminate skills in molecular genetic testing in member countries embarking on the respective techniques. We report the ten-year experience with different teaching and workshop formats for beginners in molecular diagnostics. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Handbook of technical diagnostics fundamentals and application to structures and systems

    CERN Document Server

    2013-01-01

    This book presents concepts, methods and techniques to examine symptoms of faults and failures of structures, systems and components and to monitor functional performance and structural integrity. The book is organized in five parts. Part A introduces the scope and application of technical diagnostics and gives a comprehensive overview of the physics of failure. Part B presents all relevant methods and techniques for diagnostics and monitoring: from stress, strain, vibration analysis, nondestructive evaluation, thermography and industrial radiology to computed tomography and subsurface microstructural analysis. Part C cores the principles and concepts of technical failure analysis, illustrates case studies, and outlines machinery diagnostics with an emphasis on tribological systems. Part D describes the application of structural health monitoring and performance control to plants and the technical infrastructure, including buildings, bridges, pipelines, electric power stations, offshore wind structures, and r...

  11. Applicability of the 2001 revised diagnostic criteria in Brazilian Vogt-Koyanagi-Harada disease patients.

    Science.gov (United States)

    Cardoso, Isabel Habeyche; Zajdenweber, Moysés Eduardo; Muccioli, Cristina; Fimamor, Luciana Peixoto; Belfort, Rubens

    2008-01-01

    To determine the applicability of the international revised diagnostic criteria for Vogt-Koyanagi-Harada disease. Retrospective study. Medical charts of 140 patients with the diagnosis of Vogt-Koyanagi-Harada disease, from the Uveitis Sector of the Federal University of Sao Paulo (UNIFESP), were revised and classified following the revised diagnostic criteria. Of the 140 patients, 12.85% fulfilled the criteria for complete disease, 29.28% incomplete disease, 28.57% "probable" Vogt-Koyanagi-Harada disease and 28.27% were considered not Vogt-Koyanagi-Harada disease. The authors consider that the international revised diagnostic criteria have good applicability and are very useful to help in the diagnosis of Vogt-Koyanagi-Harada disease.

  12. Effect of clinical specialist physiotherapists in orthopaedic diagnostic setting - A systematic review

    DEFF Research Database (Denmark)

    Trøstrup, Jeanette; Mikkelsen, Lone Ramer; Juhl, Carsten

    Relevance: Patients with musculoskeletal complaints are commonly referred to orthopaedic surgeons (OS) with 20 % of patients in primary care being referred to OS consultation. A high proportion of these referrals is not relevant for surgery and can potentially be managed entirely by physiotherapist...... with advanced clinical competencies; Clinical Specialist Physiotherapists (CSP). The use of CSPs instead of OSs to perform diagnostic assessment of patients with musculoskeletal complaints has been implemented in several countries (1). Earlier systematic reviews have evaluated CSPs effectiveness in diagnosing...... patients with musculoskeletal complaints and concluded that CSPs have the ability to diagnose musculoskeletal conditions (2), however since then more new studies have been published. Purpose: To evaluate the effectiveness of assessment of musculoskeletal complaints performed by CSP compared to OS...

  13. Diagnostic efficacy and therapeutic impact of computed tomography in the evaluation of clinically suspected otosclerosis

    International Nuclear Information System (INIS)

    Dudau, Cristina; Salim, Fakhruddin; Jiang, Dan; Connor, Steve E.J.

    2017-01-01

    To assess the diagnostic efficacy and therapeutic impact of CT in evaluating patients with clinically suspected otosclerosis. CT scans performed over a 5-year period for clinically suspected otosclerosis were retrospectively reviewed. CT diagnoses were correlated with subsequent surgical management. For otosclerosis positive cases, clinically significant extensions of otosclerosis were correlated with audiometry and the diagnosis was correlated with surgical findings. Of 259 CT studies, 46 % of patients were positive, 49 % negative and 5 % equivocal for otosclerosis. A relevant alternative CT diagnosis was evident in 33 % of the negative studies. One targeted surgery was performed for every four CT studies. CT outcome influenced the decision to perform stapedectomy in 41 % CT-positive versus 4 % CT-negative patients. CT-positive ears for otosclerosis could not be predicted from baseline clinical or audiometric criteria. Those with endosteal extension demonstrated lower bone conduction thresholds presurgically. The positive predictive value of CT diagnosis of otosclerosis was 100 %. CT demonstrated a high rate of clinically relevant diagnoses in both CT-positive and -negative for otosclerosis patients, and this frequently influenced surgical management. CT also added value by demonstrating relevant extensions of the otosclerotic foci, some of which were predictive of audiometric parameters. (orig.)

  14. Diagnostic and prognostic accuracy of clinical and laboratory parameters in community-acquired pneumonia

    Directory of Open Access Journals (Sweden)

    Nusbaumer Charly

    2007-03-01

    Full Text Available Abstract Background Community-acquired pneumonia (CAP is the most frequent infection-related cause of death. The reference standard to diagnose CAP is a new infiltrate on chest radiograph in the presence of recently acquired respiratory signs and symptoms. This study aims to evaluate the diagnostic and prognostic accuracy of clinical signs and symptoms and laboratory biomarkers for CAP. Methods 545 patients with suspected lower respiratory tract infection, admitted to the emergency department of a university hospital were included in a pre-planned post-hoc analysis of two controlled intervention trials. Baseline assessment included history, clinical examination, radiography and measurements of procalcitonin (PCT, highly sensitive C-reactive protein (hsCRP and leukocyte count. Results Of the 545 patients, 373 had CAP, 132 other respiratory tract infections, and 40 other final diagnoses. The AUC of a clinical model including standard clinical signs and symptoms (i.e. fever, cough, sputum production, abnormal chest auscultation and dyspnea to diagnose CAP was 0.79 [95% CI, 0.75–0.83]. This AUC was significantly improved by including PCT and hsCRP (0.92 [0.89–0.94]; p Conclusion PCT, and to a lesser degree hsCRP, improve the accuracy of currently recommended approaches for the diagnosis of CAP, thereby complementing clinical signs and symptoms. PCT is useful in the severity assessment of CAP.

  15. Diagnostic efficacy and therapeutic impact of computed tomography in the evaluation of clinically suspected otosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Dudau, Cristina [King' s College Hospital NHS Foundation Trust, Department of Neuroradiology, London (United Kingdom); Salim, Fakhruddin; Jiang, Dan [Department of Otolaryngology, Head and Neck Surgery, Auditory Implantation Centre, London (United Kingdom); Connor, Steve E.J. [Department of Radiology, Guy' s and St Thomas' NHS Foundation Trust, London (United Kingdom)

    2017-03-15

    To assess the diagnostic efficacy and therapeutic impact of CT in evaluating patients with clinically suspected otosclerosis. CT scans performed over a 5-year period for clinically suspected otosclerosis were retrospectively reviewed. CT diagnoses were correlated with subsequent surgical management. For otosclerosis positive cases, clinically significant extensions of otosclerosis were correlated with audiometry and the diagnosis was correlated with surgical findings. Of 259 CT studies, 46 % of patients were positive, 49 % negative and 5 % equivocal for otosclerosis. A relevant alternative CT diagnosis was evident in 33 % of the negative studies. One targeted surgery was performed for every four CT studies. CT outcome influenced the decision to perform stapedectomy in 41 % CT-positive versus 4 % CT-negative patients. CT-positive ears for otosclerosis could not be predicted from baseline clinical or audiometric criteria. Those with endosteal extension demonstrated lower bone conduction thresholds presurgically. The positive predictive value of CT diagnosis of otosclerosis was 100 %. CT demonstrated a high rate of clinically relevant diagnoses in both CT-positive and -negative for otosclerosis patients, and this frequently influenced surgical management. CT also added value by demonstrating relevant extensions of the otosclerotic foci, some of which were predictive of audiometric parameters. (orig.)

  16. Uptake and Diagnostic Yield of Chromosomal Microarray in an Australian Child Development Clinic

    Directory of Open Access Journals (Sweden)

    Dylan Mordaunt

    2014-05-01

    Full Text Available Autism is an etiologically heterogeneous developmental disorder for which the range of genetic investigations has expanded considerably over the past decade. Introduction of chromosomal microarray (CMA to clinical practice has expanded the range of conditions which pediatricians are able to detect. This study reviewed the utilization, yield and cost of genetic investigations in a sample of children with pervasive developmental disorders (PDD in an Australian metropolitan child development service. Six hundred and ninety eight patients with PDD were identified from the clinic population. One hundred and ten (15.7% of the clinic population had undergone investigation with chromosomal microarray, 140 (20.0% with karyotype (KT, and 167 (23.9% with Fragile X testing (FRGX. Twelve (10.9% CMA findings were reported, of which seven (6.3% were felt to be the likely cause of the child’s clinical features. Five (3.5% KT findings were reported, of which four (2.9% were felt to be the likely cause of the child’s clinical features. Two patients (1.2% were identified with Fragile X expansions. One fifth of the clinic’s recent PDD population had undergone testing with CMA. CMA appears to have increased the diagnostic yield of the genetic investigation of autism, in line with internationally reported levels. Number needed to test (NNT and cost per incremental diagnosis, were also in line with internationally reported levels.

  17. Evidence That a Psychopathology Interactome Has Diagnostic Value, Predicting Clinical Needs: An Experience Sampling Study

    Science.gov (United States)

    van Os, Jim; Lataster, Tineke; Delespaul, Philippe; Wichers, Marieke; Myin-Germeys, Inez

    2014-01-01

    Background For the purpose of diagnosis, psychopathology can be represented as categories of mental disorder, symptom dimensions or symptom networks. Also, psychopathology can be assessed at different levels of temporal resolution (monthly episodes, daily fluctuating symptoms, momentary fluctuating mental states). We tested the diagnostic value, in terms of prediction of treatment needs, of the combination of symptom networks and momentary assessment level. Method Fifty-seven patients with a psychotic disorder participated in an ESM study, capturing psychotic experiences, emotions and circumstances at 10 semi-random moments in the flow of daily life over a period of 6 days. Symptoms were assessed by interview with the Positive and Negative Syndrome Scale (PANSS); treatment needs were assessed using the Camberwell Assessment of Need (CAN). Results Psychotic symptoms assessed with the PANSS (Clinical Psychotic Symptoms) were strongly associated with psychotic experiences assessed with ESM (Momentary Psychotic Experiences). However, the degree to which Momentary Psychotic Experiences manifested as Clinical Psychotic Symptoms was determined by level of momentary negative affect (higher levels increasing probability of Momentary Psychotic Experiences manifesting as Clinical Psychotic Symptoms), momentary positive affect (higher levels decreasing probability of Clinical Psychotic Symptoms), greater persistence of Momentary Psychotic Experiences (persistence predicting increased probability of Clinical Psychotic Symptoms) and momentary environmental stress associated with events and activities (higher levels increasing probability of Clinical Psychotic Symptoms). Similarly, the degree to which momentary visual or auditory hallucinations manifested as Clinical Psychotic Symptoms was strongly contingent on the level of accompanying momentary paranoid delusional ideation. Momentary Psychotic Experiences were associated with CAN unmet treatment needs, over and above PANSS

  18. Adult Attention Deficit Hyperactivity Disorder: Neurobiology, Diagnostic Problems and Clinical Features

    Directory of Open Access Journals (Sweden)

    Cengiz Tuglu

    2010-04-01

    Full Text Available Attention-deficit/hyperactivity disorder (ADHD is a chronic, lifelong neurobeha-vioral disorder with childhood-onset, which seriously impairs the affected adults in a variety of daily living functions like academic, social and occupational functioning. Prevalence of ADHD declines with age in the general population. The approximate prevalence rates of ADHD is 8% in childhood, 6% in adolescence and 4% in adulthood. The unclear validity of DSM-IV diagnostic criteria for this condition can lead to reduced prevalence rates by underestimation of the prevalence of adult ADHD. The disorder is characterized by behavioral symptoms of inattention, hyperactivity, and impulsivity across the life cycle and is associated with considerable morbidity and disability. Although its etiology remains unclear, considerable evidence documents its strong neurobiological and genetic underpinnings. ADHD is associated with a high percentage of comorbid psychiatric disorders in every lifespan. In adulthood between 65-89% of all patients with ADHD suffer from one or more additional psychiatric disorders, above all mood and anxiety disorders, substance use disorders and personality disorders, which complicate the clinical picture in terms of diagnostics, treatment and outcome issues. The high comorbidity with other psychiatric disorders, the resulting deficits in social competences and risky health behavior that often go along with a diminished life quality must be stressed in these patients. Preventive and therapeutic interventions should be taken at an early stage to counteract the possible negative influences of ADHD on functioning and relationships. In this paper, we reviewed the historical aspects, epidemiology, neurobiology, comorbidity, diagnostic difficulties and clinical features of adult ADHD.

  19. Low back pain in school-age children: risk factors, clinical features and diagnostic managment.

    Science.gov (United States)

    Boćkowski, L; Sobaniec, W; Kułak, W; Smigielska-Kuzia, J; Sendrowski, K; Roszkowska, M

    2007-01-01

    Low back pain (LBP) is common in adult population, and it is becoming a serious health concern in adolescents. On surveys, about every fifth child in the school-age reports LBP. The study objective was to analysis the natural history, risk factors, clinical symptoms, causes and diagnostic management in school-age children hospitalized with LBP. The study group consisted of 36 patients at the age between 10 and 18 years, 22 girls and 14 boys suffering from LBP hospitalized in our Department of Pediatric Neurology and Rehabilitation in years 2000-2004. The mean age of clinical onset of LBP in our group was 14.7 years, earlier in girls, later in boys. We find the family history of LBP in 50% children. Most frequent factors associated with LBP were: spina bifida (16.7%) and incorrect posture (13.9%). Half of patients pointed the factor initialising LBP: rapid, incoordinated move (39%) or heavy load rise (11%). 58% of patients present the symptoms of ischialgia. Diagnostic imaging showed disc protrusion in 11 children (31%) 6 in computed tomography, 4 in magnetic resonance imaging and 1 in X-Ray examination only. Other causes of LBP included: spondylolysis in 2 patients, Scheuermann disease in one case and juvenile reumatoid arthritis in one case. Some school-age children suffering on low back pain, particulary with sciatic neuralgia symptoms seek medical care in hospital. Althought the main causes are mechanical, associated with lack of physical activity or strenous exercise, serious diagnostic managment is strongly recommended.

  20. Applications of nanoparticles in cancer detection and diagnostic tool for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Venkatasalam, C.; Nagappan, A.

    2012-01-01

    Cancer nanotechnology is multidisciplinary area of science and technology. In recent days nano particles are used in medical field as diagnostic tools. It is highly precious and accurate measurement tools for detecting many disease. One of the broad application of cancer biology, for detecting molecular imaging, molecular diagnosis of cancer cells. In the present study deals with the nanoparticles are widely used for finding tumor as biomarker imaging for cancer detection and the nanoparticles are have important notice. An ample choice of materials may be used for construct nanoparticles that can cover for increase the capability of delivery or to provide unique structural and electrical properties for imaging. This exclusive properties are worn to several functional nanoparticles have already been demonstrated, including some clinically approved liposome drugs and metallic imaging agents. In early detection of heptocellular carcinoma, the metallic nanoparticles are vital role in the imaging technology. Several functions of nanoparticles that may eventually additional the understanding of producing imaging especially the darkening and enlarging of the images. These nanoparticles may be able to identify malignant cells by means of molecular detection, visualization of their location in the body by providing enhanced contrast in medical imaging technology, Through selective particle targeting and monitoring of identification of multiplied cells in different organs of the body. In the future prospective of medical field, the nanoparticles are having vital role for detecting cancer cells. (author)

  1. Risks to the fetus from diagnostic imaging during pregnancy: review and proposal of a clinical protocol

    International Nuclear Information System (INIS)

    Gomes, Mafalda; Matias, Alexandra; Macedo, Filipe

    2015-01-01

    Every day, medical practitioners face the dilemma of exposing pregnant or possibly pregnant patients to radiation from diagnostic examinations. Both doctors and patients often have questions about the risks of radiation. The most vulnerable period is between the 8th and 15th weeks of gestation. Deterministic effects like pregnancy loss, congenital malformations, growth retardation and neurobehavioral abnormalities have threshold doses above 100-200 mGy. The risk is considered negligible at 50 mGy and in reality no diagnostic examination exceeds this limit. The risk of carcinogenesis is slightly higher than in the general population. Intravenous iodinated contrast is discouraged, except in highly selected patients. Considering all the possible noxious effects of radiation exposure, measures to diminish radiation are essential and affect the fetal outcome. Nonionizing procedures should be considered whenever possible and every radiology center should have its own data analysis on fetal radiation exposure. In this review, we analyze existing literature on fetal risks due to radiation exposure, producing a clinical protocol to guide safe radiation use in a clinical setting. (orig.)

  2. Risks to the fetus from diagnostic imaging during pregnancy: review and proposal of a clinical protocol.

    Science.gov (United States)

    Gomes, Mafalda; Matias, Alexandra; Macedo, Filipe

    2015-12-01

    Every day, medical practitioners face the dilemma of exposing pregnant or possibly pregnant patients to radiation from diagnostic examinations. Both doctors and patients often have questions about the risks of radiation. The most vulnerable period is between the 8th and 15th weeks of gestation. Deterministic effects like pregnancy loss, congenital malformations, growth retardation and neurobehavioral abnormalities have threshold doses above 100-200 mGy. The risk is considered negligible at 50 mGy and in reality no diagnostic examination exceeds this limit. The risk of carcinogenesis is slightly higher than in the general population. Intravenous iodinated contrast is discouraged, except in highly selected patients. Considering all the possible noxious effects of radiation exposure, measures to diminish radiation are essential and affect the fetal outcome. Nonionizing procedures should be considered whenever possible and every radiology center should have its own data analysis on fetal radiation exposure. In this review, we analyze existing literature on fetal risks due to radiation exposure, producing a clinical protocol to guide safe radiation use in a clinical setting.

  3. A Meta-analysis for the Diagnostic Performance of Transient Elastography for Clinically Significant Portal Hypertension.

    Science.gov (United States)

    You, Myung-Won; Kim, Kyung Won; Pyo, Junhee; Huh, Jimi; Kim, Hyoung Jung; Lee, So Jung; Park, Seong Ho

    2017-01-01

    We aimed to evaluate the correlation between liver stiffness measurement using transient elastography (TE-LSM) and hepatic venous pressure gradient and the diagnostic performance of TE-LSM in assessing clinically significant portal hypertension through meta-analysis. Eleven studies were included from thorough literature research and selection processes. The summary correlation coefficient was 0.783 (95% confidence interval [CI], 0.737-0.823). Summary sensitivity, specificity and area under the hierarchical summary receiver operating characteristic curve (AUC) were 87.5% (95% CI, 75.8-93.9%), 85.3 % (95% CI, 76.9-90.9%) and 0.9, respectively. The subgroup with low cut-off values of 13.6-18 kPa had better summary estimates (sensitivity 91.2%, specificity 81.3% and partial AUC 0.921) than the subgroup with high cut-off values of 21-25 kPa (sensitivity 71.2%, specificity 90.9% and partial AUC 0.769). In summary, TE-LSM correlated well with hepatic venous pressure gradient and represented good diagnostic performance in diagnosing clinically significant portal hypertension. For use as a sensitive screening tool, we propose using low cut-off values of 13.6-18 kPa in TE-LSM. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. Update on oral Chagas disease outbreaks in Venezuela: epidemiological, clinical and diagnostic approaches

    Science.gov (United States)

    de Noya, Belkisyolé Alarcón; Díaz-Bello, Zoraida; Colmenares, Cecilia; Ruiz-Guevara, Raiza; Mauriello, Luciano; Muñoz-Calderón, Arturo; Noya, Oscar

    2015-01-01

    Orally transmitted Chagas disease has become a matter of concern due to outbreaks reported in four Latin American countries. Although several mechanisms for orally transmitted Chagas disease transmission have been proposed, food and beverages contaminated with whole infected triatomines or their faeces, which contain metacyclic trypomastigotes of Trypanosoma cruzi, seems to be the primary vehicle. In 2007, the first recognised outbreak of orally transmitted Chagas disease occurred in Venezuela and largest recorded outbreak at that time. Since then, 10 outbreaks (four in Caracas) with 249 cases (73.5% children) and 4% mortality have occurred. The absence of contact with the vector and of traditional cutaneous and Romana’s signs, together with a florid spectrum of clinical manifestations during the acute phase, confuse the diagnosis of orally transmitted Chagas disease with other infectious diseases. The simultaneous detection of IgG and IgM by ELISA and the search for parasites in all individuals at risk have been valuable diagnostic tools for detecting acute cases. Follow-up studies regarding the microepidemics primarily affecting children has resulted in 70% infection persistence six years after anti-parasitic treatment. Panstrongylus geniculatus has been the incriminating vector in most cases. As a food-borne disease, this entity requires epidemiological, clinical, diagnostic and therapeutic approaches that differ from those approaches used for traditional direct or cutaneous vector transmission. PMID:25946155

  5. [Clinical decision making: Fostering critical thinking in the nursing diagnostic process through case studies].

    Science.gov (United States)

    Müller-Staub, Maria; Stuker-Studer, Ursula

    2006-10-01

    Case studies, based on actual patients' situations, provide a method of clinical decision making to foster critical thinking in nurses. This paper describes the method and process of group case studies applied in continuous education settings. This method bases on Balints' case supervision and was further developed and combined with the nursing diagnostic process. A case study contains different phases: Pre-phase, selection phase, case delineation and case work. The case provider narratively tells the situation of a patient. This allows the group to analyze and cluster signs and symptoms, to state nursing diagnoses and to derive nursing interventions. Results of the case study are validated by applying the theoretical background and critical appraisal of the case provider. Learning effects of the case studies were evaluated by means of qualitative questionnaires and analyzed according to Mayring. Findings revealed the following categories: a) Patients' problems are perceived in a patient centred way, accurate nursing diagnoses are stated and effective nursing interventions implemented. b) Professional nursing tasks are more purposefully perceived and named more precise. c) Professional nursing relationship, communication and respectful behaviour with patients were perceived in differentiated ways. The theoretical framework is described in the paper "Clinical decision making and critical thinking in the nursing diagnostic process". (Müller-Staub, 2006).

  6. Diagnostic reference levels in intraoral radiology: From the laboratory to clinical practice

    International Nuclear Information System (INIS)

    Alcaraz, M.; Velasco, E.; Martinez-Beneyto, Y.; Velasco, F.; Parra, C.; Canteras, M.

    2010-01-01

    To determine the diagnostic reference levels (DRLs) for obtaining a diagnostic image in the normal conditions of clinical practice and to explain the differences between the levels found and the DRLs obtained in other experimental conditions, suggesting that there has been a reduction in the European Union (EU) recommended levels. A total of 2296 official reports on dental surgeries from 16 Spanish autonomous regions compiled during 2008 were studied. A mean DRL of 3.3 mGy was determined: 2.6 mGy for installations using direct digital systems, 3.4 mGy for those using indirect systems, 4.4 mGy for those using Ultra-speed film and 3.7 mGy for those using Insight. The DRLs found in this survey are below the EU recommended values but far above previously described values, possibly because all the different systems were considered and because values refer to those of the normal work conditions of clinical practice. (authors)

  7. Risks to the fetus from diagnostic imaging during pregnancy: review and proposal of a clinical protocol

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Mafalda; Matias, Alexandra [University of Porto, Faculty of Medicine, Porto (Portugal); Macedo, Filipe [SMIC, Porto (Portugal)

    2015-12-15

    Every day, medical practitioners face the dilemma of exposing pregnant or possibly pregnant patients to radiation from diagnostic examinations. Both doctors and patients often have questions about the risks of radiation. The most vulnerable period is between the 8th and 15th weeks of gestation. Deterministic effects like pregnancy loss, congenital malformations, growth retardation and neurobehavioral abnormalities have threshold doses above 100-200 mGy. The risk is considered negligible at 50 mGy and in reality no diagnostic examination exceeds this limit. The risk of carcinogenesis is slightly higher than in the general population. Intravenous iodinated contrast is discouraged, except in highly selected patients. Considering all the possible noxious effects of radiation exposure, measures to diminish radiation are essential and affect the fetal outcome. Nonionizing procedures should be considered whenever possible and every radiology center should have its own data analysis on fetal radiation exposure. In this review, we analyze existing literature on fetal risks due to radiation exposure, producing a clinical protocol to guide safe radiation use in a clinical setting. (orig.)

  8. Advances in mass spectrometry-based cancer research and analysis: from cancer proteomics to clinical diagnostics.

    Science.gov (United States)

    Timms, John F; Hale, Oliver J; Cramer, Rainer

    2016-06-01

    The last 20 years have seen significant improvements in the analytical capabilities of biological mass spectrometry (MS). Studies using advanced MS have resulted in new insights into cell biology and the etiology of diseases as well as its use in clinical applications. This review discusses recent developments in MS-based technologies and their cancer-related applications with a focus on proteomics. It also discusses the issues around translating the research findings to the clinic and provides an outline of where the field is moving. Expert commentary: Proteomics has been problematic to adapt for the clinical setting. However, MS-based techniques continue to demonstrate potential in novel clinical uses beyond classical cancer proteomics.

  9. Hereditary neuropathies: systematization and diagnostics (clinical case of hereditary motor and sensor neuropathy of the IA type

    Directory of Open Access Journals (Sweden)

    Kolokolova A.M.

    2016-09-01

    Full Text Available Aim: to study the value of routine methods (clinical symptoms, electrophysiological findings and results of DNA analysis in diagnostics of hereditary motor sensory neuropathy type IA in outpatient clinics. Material and Methods. The review of foreign literature is represented. The phenotypic polymorphism, genetic heterogeneity and the difficulties of diagnostics are identified. A family with hereditary motor sensory neuropathy of lAtype is presented, which was diagnosed on the base of available methods in outpatient practice (clinical symptoms, genealogical method, electro-physiological findings and DNA analysis results. Results. Routine algorithm (consistent valuation of clinical symptoms, neurophysiologic findings and the results of DNA analysis helped to verify the diagnosis of hereditary motor sensory neuropathy of lAtype in outpatient practice after more than 20 years of the onset of the disease. Conclusion. The neurologists of outpatient clinics and other specialists must be informed about the availability of diagnostics of hereditary diseases of nervous system.

  10. Added Diagnostic Value of 11C-PiB-PET in Memory Clinic Patients with Uncertain Diagnosis

    Directory of Open Access Journals (Sweden)

    K.S. Frederiksen

    2012-12-01

    Full Text Available Introduction: The added diagnostic value of 11C-PiB-PET for the assessment of the accumulation of cortical beta-amyloid in memory clinic patients with uncertain diagnosis remains undetermined. Methods: All patients who underwent PiB-PET at the Copenhagen Memory Clinic between March 2008 and November 2011 were included in this uncontrolled, retrospective study. The standard diagnostic evaluation program included physical and neurological examination, cognitive and functional assessment, a cranial CT or MRI, functional imaging and cerebrospinal fluid sampling. Based on anonymized case reports, three experienced clinicians reached a consensus diagnosis and rated their confidence in the diagnosis before and after disclosure of PiB-PET ratings. PiB-PET scans were rated as either positive or negative. Results: A total of 57 patients (17 females, 30 males; age 65.7 years, range 44.2–82.6 were included in the study. Twenty-seven had a positive PiB-PET scan. At the first diagnostic evaluation, 16 patients were given a clinical Alheimer’s disease diagnosis (14 PiB positive. Of the 57 patients, 13 (23% were diagnostically reclassified after PiB-PET ratings were disclosed. The clinicians’ overall confidence in their diagnosis increased in 28 (49% patients. Conclusion: PiB-PET adds to the specialist clinical evaluation and other supplemental diagnostic investigations in the diagnostic classification of patients with uncertain diagnosis in a specialized memory clinic.

  11. Evolving Identification of Blood Cells Associated with Clinically Isolated Syndrome: Importance of Time since Clinical Presentation and Diagnostic MRI.

    Science.gov (United States)

    Trend, Stephanie; Jones, Anderson P; Geldenhuys, Sian; Byrne, Scott N; Fabis-Pedrini, Marzena J; Nolan, David; Booth, David R; Carroll, William M; Lucas, Robyn M; Kermode, Allan G; Hart, Prue H

    2017-06-15

    It is not clear how the profile of immune cells in peripheral blood differs between patients with clinically isolated syndrome (CIS) and healthy controls (HC). This study aimed to identify a CIS peripheral blood signature that may provide clues for potential immunomodulatory approaches early in disease. Peripheral blood mononuclear cells (PBMCs) were collected from 18 people with CIS, 19 HC and 13 individuals with other demyelinating conditions (ODC) including multiple sclerosis (MS). Individuals with CIS separated into two groups, namely those with early (≤14 days post-diagnostic magnetic resonance imaging (MRI); n = 6) and late (≥27 days; n = 12) blood sampling. Transitional B cells were increased in the blood of CIS patients independently of when blood was taken. However, there were two time-dependent effects found in the late CIS group relative to HC, including decreased CD56bright NK cells, which correlated significantly with time since MRI, and increased CD141+ myeloid dendritic cell (mDC2) frequencies. Higher CD1c+ B cells and lower non-classical monocyte frequencies were characteristic of more recent demyelinating disease activity (ODC and early CIS). Analysing cell populations by time since symptoms (subjective) and diagnostic MRI (objective) may contribute to understanding CIS.

  12. Current means for plasma diagnostics and their application for materials and environment control. Materials of IV Russian seminar

    International Nuclear Information System (INIS)

    2003-01-01

    The collection contains reports made at the Fourth Russian seminar Current means of plasma diagnostics and their application for materials and environment control. The seminar took place in Moscow, November 12-14, 2003. The content of the collection covers both questions of plasma diagnostics in thermonuclear reactors and problems of diagnostics of pulsed and stationary gas discharges in research and technological installations. The reports on plasma diagnostics applied for some tasks of medicine and environment control are presented [ru

  13. Applications of Diagnostic Classification Models: A Literature Review and Critical Commentary

    Science.gov (United States)

    Sessoms, John; Henson, Robert A.

    2018-01-01

    Diagnostic classification models (DCMs) classify examinees based on the skills they have mastered given their test performance. This classification enables targeted feedback that can inform remedial instruction. Unfortunately, applications of DCMs have been criticized (e.g., no validity support). Generally, these evaluations have been brief and…

  14. Development of high performance Schottky barrier diode and its application to plasma diagnostics

    International Nuclear Information System (INIS)

    Fujita, Junji; Kawahata, Kazuo; Okajima, Shigeki

    1993-10-01

    At the conclusion of the Supporting Collaboration Research on 'Development of High Performance Detectors in the Far Infrared Range' carried out from FY1990 to FY1992, the results of developing Schottky barrier diode and its application to plasma diagnostics are summarized. Some remarks as well as technical know-how for the correct use of diodes are also described. (author)

  15. Clinical Factors and Disease Course Related to Diagnostic Delay in Korean Crohn's Disease Patients: Results from the CONNECT Study.

    Directory of Open Access Journals (Sweden)

    Chang Mo Moon

    Full Text Available Diagnostic delay frequently occurs in Crohn's disease (CD patients because of diagnostic limitations. However, diagnostic delay and its related factors remain poorly defined. Therefore, we aimed to identify the predictors associated with diagnostic delay and to evaluate the impact of diagnostic delay on clinical course in a Korean CD patient cohort. We performed a multicenter retrospective analysis of 1,047 CD patients registered in the Crohn's Disease Clinical Network and Cohort study in Korea. The mean interval of diagnostic delay was 16.0 ± 33.1 months. Multivariate analysis showed that older age at diagnosis (≥40 years (p = 0.014, concomitant upper gastrointestinal (UGI disease (p = 0.012 and penetrating disease behavior at diagnosis (p = 0.001 were positively associated with long diagnostic delay (≥18 months. During the longitudinal follow-up, long diagnostic delay was independently predictive of further development of intestinal stenosis (hazard ratio [HR], 1.43; 95% confidence interval [CI], 1.07-1.93; p = 0.017, internal fistulas (HR, 1.62; 95% CI, 1.12-2.33; p = 0.011, and perianal fistulas (HR, 1.38; 95% CI, 1.06-1.80; p = 0.016. However, as for the risk of abscess formation, bowel perforation, and CD-related abdominal surgery, no significant association with diagnostic delay was observed. Older age at diagnosis, UGI involvement, and penetrating behavior are associated with long diagnostic delay in Korean CD patients. Moreover, diagnostic delay is associated with an increased risk of CD-related complications such as intestinal stenosis, internal fistulas, and perianal fistulas.

  16. Diagnostic criteria, clinical features, and incidence of thyroid storm based on nationwide surveys.

    Science.gov (United States)

    Akamizu, Takashi; Satoh, Tetsurou; Isozaki, Osamu; Suzuki, Atsushi; Wakino, Shu; Iburi, Tadao; Tsuboi, Kumiko; Monden, Tsuyoshi; Kouki, Tsuyoshi; Otani, Hajime; Teramukai, Satoshi; Uehara, Ritei; Nakamura, Yosikazu; Nagai, Masaki; Mori, Masatomo

    2012-07-01

    /dL. TS is still a life-threatening disorder with more than 10% mortality in Japan. We present newly formulated diagnostic criteria for TS and clarify its clinical features, prognosis, and incidence based on nationwide surveys in Japan. This information will help diagnose TS and in understanding the factors contributing to mortality and irreversible complications.

  17. Evaluating a mobile application for improving clinical laboratory test ordering and diagnosis.

    Science.gov (United States)

    Meyer, Ashley N D; Thompson, Pamela J; Khanna, Arushi; Desai, Samir; Mathews, Benji K; Yousef, Elham; Kusnoor, Anita V; Singh, Hardeep

    2018-04-20

    Mobile applications for improving diagnostic decision making often lack clinical evaluation. We evaluated if a mobile application improves generalist physicians' appropriate laboratory test ordering and diagnosis decisions and assessed if physicians perceive it as useful for learning. In an experimental, vignette study, physicians diagnosed 8 patient vignettes with normal prothrombin times (PT) and abnormal partial thromboplastin times (PTT). Physicians made test ordering and diagnosis decisions for 4 vignettes using each resource: a mobile app, PTT Advisor, developed by the Centers for Disease Control and Prevention (CDC)'s Clinical Laboratory Integration into Healthcare Collaborative (CLIHC); and usual clinical decision support. Then, physicians answered questions regarding their perceptions of the app's usefulness for diagnostic decision making and learning using a modified Kirkpatrick Training Evaluation Framework. Data from 368 vignettes solved by 46 physicians at 7 US health care institutions show advantages for using PTT Advisor over usual clinical decision support on test ordering and diagnostic decision accuracy (82.6 vs 70.2% correct; P < .001), confidence in decisions (7.5 vs 6.3 out of 10; P < .001), and vignette completion time (3:02 vs 3:53 min.; P = .06). Physicians reported positive perceptions of the app's potential for improved clinical decision making, and recommended it be used to address broader diagnostic challenges. A mobile app, PTT Advisor, may contribute to better test ordering and diagnosis, serve as a learning tool for diagnostic evaluation of certain clinical disorders, and improve patient outcomes. Similar methods could be useful for evaluating apps aimed at improving testing and diagnosis for other conditions.

  18. Accuracy of a Diagnostic Algorithm to Diagnose Breakthrough Cancer Pain as Compared With Clinical Assessment.

    Science.gov (United States)

    Webber, Katherine; Davies, Andrew N; Cowie, Martin R

    2015-10-01

    Breakthrough cancer pain (BTCP) is a heterogeneous condition, and there are no internationally agreed standardized criteria to diagnose it. There are published algorithms to assist with diagnosis, but these differ in content. There are no comparative data to support use. To compare the diagnostic ability of a simple algorithm against a comprehensive clinical assessment to diagnose BTCP and to assess if verbal rating descriptors can adequately discriminate controlled background pain. Patients with cancer pain completed a three-step algorithm with a researcher to determine if they had controlled background pain and BTCP. This was followed by a detailed pain consultation with a clinical specialist who was blinded to the algorithm results and determined an independent pain diagnosis. The sensitivity, specificity, and positive and negative predictive values were calculated for the condition of BTCP. Further analysis determined which verbal pain severity descriptors corresponded with the condition of controlled background pain. The algorithm had a sensitivity of 0.54 and a specificity of 0.76 in the identification of BTCP. The positive predictive value was 0.7, and the negative predictive value was 0.62. The sensitivity of a background pain severity rating of mild or less to accurately categorize controlled background pain was 0.69 compared with 0.97 for severity of moderate or less; however, this was balanced by a higher specificity rating for mild or less, 0.78 compared with 0.2. The diagnostic breakthrough pain algorithm had a good positive predictive value but limited sensitivity using a cutoff score of "mild" to define controlled background pain. When the cutoff level was changed to moderate, the sensitivity increased, but specificity reduced. A comprehensive clinical assessment remains the preferred method to diagnose BTCP. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  19. Automatic Decision Support for Clinical Diagnostic Literature Using Link Analysis in a Weighted Keyword Network.

    Science.gov (United States)

    Li, Shuqing; Sun, Ying; Soergel, Dagobert

    2017-12-23

    We present a novel approach to recommending articles from the medical literature that support clinical diagnostic decision-making, giving detailed descriptions of the associated ideas and principles. The specific goal is to retrieve biomedical articles that help answer questions of a specified type about a particular case. Based on the filtered keywords, MeSH(Medical Subject Headings) lexicon and the automatically extracted acronyms, the relationship between keywords and articles was built. The paper gives a detailed description of the process of by which keywords were measured and relevant articles identified based on link analysis in a weighted keywords network. Some important challenges identified in this study include the extraction of diagnosis-related keywords and a collection of valid sentences based on the keyword co-occurrence analysis and existing descriptions of symptoms. All data were taken from medical articles provided in the TREC (Text Retrieval Conference) clinical decision support track 2015. Ten standard topics and one demonstration topic were tested. In each case, a maximum of five articles with the highest relevance were returned. The total user satisfaction of 3.98 was 33% higher than average. The results also suggested that the smaller the number of results, the higher the average satisfaction. However, a few shortcomings were also revealed since medical literature recommendation for clinical diagnostic decision support is so complex a topic that it cannot be fully addressed through the semantic information carried solely by keywords in existing descriptions of symptoms. Nevertheless, the fact that these articles are actually relevant will no doubt inspire future research.

  20. The Importance of Conditional Probability in Diagnostic Reasoning and Clinical Decision Making: A Primer for the Eye Care Practitioner.

    Science.gov (United States)

    Sanfilippo, Paul G; Hewitt, Alex W; Mackey, David A

    2017-04-01

    To outline and detail the importance of conditional probability in clinical decision making and discuss the various diagnostic measures eye care practitioners should be aware of in order to improve the scope of their clinical practice. We conducted a review of the importance of conditional probability in diagnostic testing for the eye care practitioner. Eye care practitioners use diagnostic tests on a daily basis to assist in clinical decision making and optimizing patient care and management. These tests provide probabilistic information that can enable the clinician to increase (or decrease) their level of certainty about the presence of a particular condition. While an understanding of the characteristics of diagnostic tests are essential to facilitate proper interpretation of test results and disease risk, many practitioners either confuse or misinterpret these measures. In the interests of their patients, practitioners should be aware of the basic concepts associated with diagnostic testing and the simple mathematical rule that underpins them. Importantly, the practitioner needs to recognize that the prevalence of a disease in the population greatly determines the clinical value of a diagnostic test.

  1. Mismatch negativity: clinical and other applications.

    Science.gov (United States)

    Näätänen, R; Escera, C

    2000-01-01

    The perspectives of application of the mismatch negativity (MMN), generated by the brain's automatic response to change in auditory stimulation, are discussed. In light of the fact that the MMN (and its magnetic equivalent MMNm) currently provides the only objective measure of the accuracy of the central auditory function, these perspectives appear very promising. The MMN can be measured in the absence of attention and task requirements, which makes it particularly suitable for testing different clinical populations and infants. Furthermore, the MMN enables one to evaluate the accuracy of auditory discrimination separately for any acoustic feature, such as frequency, intensity and duration, and for learned categories, such as the phonemes of a particular language. In addition, by measuring the decay of the MMN amplitude as a function of the interstimulus interval, it is possible to estimate the duration of sensory (echoic) memory. Copyright 2000 S. Karger AG, Basel

  2. Clinical application of magnetic resonance coronary angiography

    International Nuclear Information System (INIS)

    Murakami, Akihiko; Onoe, Teruyuki; Kodera, Akifumi; Ohtsuki, Tetsuya; Shiomi, Akio; Ida, Masaaki; Sawada, Takahisa

    1999-01-01

    We performed the magnetic resonance coronary angiography (MRCA) in the cases which underwent coronary angiography (CAG) and obtained images were compared. Lesion with significant constriction more than 75% on CAG were determined as abnormal findings on MRCA, however, lesions with about 50% constriction were as the normal findings. On the assessment of the re-constriction after PTCA, the changes in signal were found in about half of cases. This may come from the contribution of flexion lesions, the difficulty to assess moderate constriction after PTCA, etc. For the anomalous aortic origin of coronary artery, peripheral large vessels could be simultaneously imaged by MRCA and be also assessed among their clear spatial relationship. Although MRCA has some problems on the assessment for flexion or moderate constriction, these results suggested that MRCA is useful to clinical application as the non-invasive examination. (K.H.)

  3. Coleopteran Antimicrobial Peptides: Prospects for Clinical Applications

    Directory of Open Access Journals (Sweden)

    Monde Ntwasa

    2012-01-01

    Full Text Available Antimicrobial peptides (AMPs are activated in response to septic injury and have important roles in vertebrate and invertebrate immune systems. AMPs act directly against pathogens and have both wound healing and antitumor activities. Although coleopterans comprise the largest and most diverse order of eukaryotes and occupy an earlier branch than Drosophila in the holometabolous lineage of insects, their immune system has not been studied extensively. Initial research reports, however, indicate that coleopterans possess unique immune response mechanisms, and studies of these novel mechanisms may help to further elucidate innate immunity. Recently, the complete genome sequence of Tribolium was published, boosting research on coleopteran immunity and leading to the identification of Tribolium AMPs that are shared by Drosophila and mammals, as well as other AMPs that are unique. AMPs have potential applicability in the development of vaccines. Here, we review coleopteran AMPs, their potential impact on clinical medicine, and the molecular basis of immune defense.

  4. Applications of pattern recognition theory in diagnostics of nuclear power plants

    International Nuclear Information System (INIS)

    Cech, J.

    1982-01-01

    The questions are discussed of the application of the theory of pattern recognition in the diagnostics of nuclear power plants. For the future use of recognition systems in the diagnostics of nuclear power plants it is obvious that like with other complex systems, optimal models will have to be used which will organize the optimal recognition algorithm. The conclusion is presented that for the needs of nuclear power plants special systems will be more suitable for pattern recognition than digital computers which are flexible and adaptible but have a lower decision rate, an insufficient working memory, complicated programs, etc. (Z.M.)

  5. Enrichment of target sequences for next-generation sequencing applications in research and diagnostics.

    Science.gov (United States)

    Altmüller, Janine; Budde, Birgit S; Nürnberg, Peter

    2014-02-01

    Abstract Targeted re-sequencing such as gene panel sequencing (GPS) has become very popular in medical genetics, both for research projects and in diagnostic settings. The technical principles of the different enrichment methods have been reviewed several times before; however, new enrichment products are constantly entering the market, and researchers are often puzzled about the requirement to take decisions about long-term commitments, both for the enrichment product and the sequencing technology. This review summarizes important considerations for the experimental design and provides helpful recommendations in choosing the best sequencing strategy for various research projects and diagnostic applications.

  6. Impact of delay in clinical presentation on the diagnostic management and prognosis of patients with suspected pulmonary embolism

    NARCIS (Netherlands)

    Den Exter, Paul L.; Van Es, Josien; Erkens, Petra M.G.; Van Roosmalen, Mark J.G.; Van Den Hoven, Pim; Hovens, Marcel M.C.; Kamphuisen, Pieter W.; Klok, Frederikus A.; Huisman, Menno V.

    2013-01-01

    Rationale: The nonspecific clinical presentation of pulmonary embolism (PE) frequently leads to delay in its diagnosis. Objectives: This study aimed to assess the impact of delay in presentation on the diagnostic management and clinical outcome of patients with suspected PE. Methods: In 4,044

  7. Impact of delay in clinical presentation on the diagnostic management and prognosis of patients with suspected pulmonary embolism

    NARCIS (Netherlands)

    Den Exter, P. L.; Van Es, J.; Erkens, P. G. M.; Roosmalen, M.; Hoven, P.; Hovens, M.; Kamphuisen, P. W.; Klok, F. A.; Huisman, M.

    Background: The non-specific clinical presentation of pulmonary embolism (PE) frequently leads to delay in its diagnosis. Aims: To assess the impact of delay in presentation on the diagnostic management and clinical outcome of patients with suspected PE. Methods: For this post-hoc analysis, we used

  8. The value of the clinical geneticist caring for adults with congenital heart disease: diagnostic yield and patients' perspective

    NARCIS (Netherlands)

    van Engelen, Klaartje; Baars, Marieke J. H.; Felix, Joyce P.; Postma, Alex V.; Mulder, Barbara J. M.; Smets, Ellen M. A.

    2013-01-01

    For adult patients with congenital heart disease (CHD), knowledge about the origin and inheritance of their CHD is important. Clinical geneticists may play a significant role in their care. We explored the diagnostic yield of clinical genetic consultation of adult CHD patients, patients' motivations

  9. CLASSIFICATION OF TEMPOROMANDIBULAR-JOINT OSTEOARTHROSIS AND INTERNAL DERANGEMENT .1. DIAGNOSTIC-SIGNIFICANCE OF CLINICAL AND RADIOGRAPHIC SYMPTOMS AND SIGNS

    NARCIS (Netherlands)

    STEGENGA, B; DEBONT, LGM; VANDERKUIJL, B; BOERING, G

    In the clinical setting, diagnosis primarily depends on the history and present status of the patient, and on the examiner's expertise in physical examination and interpretation of conventional radiographs. In order to evaluate the diagnostic significance of clinical and radiographic variables, the

  10. Assessment Procedures for Narcissistic Personality Disorder: A Comparison of the Personality Diagnostic Questionnaire-4 and Best-Estimate Clinical Judgments

    Science.gov (United States)

    Miller, Joshua D.; Campbell, W. Keith; Pilkonis, Paul A.; Morse, Jennifer Q.

    2008-01-01

    This study examined the degree of correspondence between two assessments for narcissistic personality disorder (NPD) in a mixed clinical and community sample--one using a self-report measure (Personality Diagnostic Questionnaire-4) and the other using clinical judgments derived from an assessment based on the longitudinal, expert, all data (LEAD)…

  11. Variation in the Use of Vestibular Diagnostic Testing for Patients Presenting to Otolaryngology Clinics with Dizziness

    Science.gov (United States)

    Piker, Erin G.; Schulz, Kris; Parham, Kourosh; Vambutas, Andrea; Witsell, David; Tucci, Debara; Shin, Jennifer J.; Pynnonen, Melissa A.; Nguyen-Huynh, Anh; Crowson, Matthew; Ryan, Sheila E.; Langman, Alan; Roberts, Rhonda; Wolfley, Anne; Lee, Walter T.

    2016-01-01

    Objective We used a national otolaryngology practice–based research network database to characterize the utilization of vestibular function testing in patients diagnosed with dizziness and/or a vestibular disorder. Study Design Database review. Setting The Creating Healthcare Excellence through Education and Research (CHEER) practice-based research network of academic and community providers Subjects and Methods Dizzy patients in the CHEER retrospective database were identified through ICD-9 codes; vestibular testing procedures were identified with CPT codes. Demographics and procedures per patient were tabulated. Analysis included number and type of vestibular tests ordered, stratified by individual clinic and by practice type (community vs academic). Chi-square tests were performed to assess if the percentage of patients receiving testing was statistically significant across clinics. A logistic regression model was used to examine the association between receipt of testing and being tested on initial visit. Results A total of 12,468 patients diagnosed with dizziness and/or a vestibular disorder were identified from 7 community and 5 academic CHEER network clinics across the country. One-fifth of these patients had at least 1 vestibular function test. The percentage of patients tested varied widely by site, from 3% to 72%; academic clinics were twice as likely to test. Initial visit vestibular testing also varied, from 0% to 96% of dizzy patients, and was 15 times more likely in academic clinics. Conclusion There is significant variation in use and timing of vestibular diagnostic testing across otolaryngology clinics. The CHEER network research database does not contain outcome data. These results illustrate the critical need for research that examines outcomes as related to vestibular testing. PMID:27371625

  12. Optical diagnostics based on elastic scattering: Recent clinical demonstrations with the Los Alamos Optical Biopsy System

    Energy Technology Data Exchange (ETDEWEB)

    Bigio, I.J.; Loree, T.R.; Mourant, J.; Shimada, T. [Los Alamos National Lab., NM (United States); Story-Held, K.; Glickman, R.D. [Texas Univ. Health Science Center, San Antonio, TX (United States). Dept. of Ophthalmology; Conn, R. [Lovelace Medical Center, Albuquerque, NM (United States). Dept. of Urology

    1993-08-01

    A non-invasive diagnostic tool that could identify malignancy in situ and in real time would have a major impact on the detection and treatment of cancer. We have developed and are testing early prototypes of an optical biopsy system (OBS) for detection of cancer and other tissue pathologies. The OBS invokes a unique approach to optical diagnosis of tissue pathologies based on the elastic scattering properties, over a wide range of wavelengths, of the microscopic structure of the tissue. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact that many tissue pathologies, including a majority of cancer forms, manifest significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be strongly wavelength dependent. Thus, morphology and size changes can be expected to cause significant changes in an optical signature that is derived from the wavelength dependence of elastic scattering. The data acquisition and storage/display time with the OBS instrument is {approximately}1 second. Thus, in addition to the reduced invasiveness of this technique compared with current state-of-the-art methods (surgical biopsy and pathology analysis), the OBS offers the possibility of impressively faster diagnostic assessment. The OBS employs a small fiber-optic probe that is amenable to use with any endoscope, catheter or hypodermic, or to direct surface examination (e.g. as in skin cancer or cervical cancer). It has been tested in vitro on animal and human tissue samples, and clinical testing in vivo is currently in progress.

  13. Introduction of spirometry into clinical practice in Georgetown, Guyana: quality and diagnostic outcomes.

    Science.gov (United States)

    Johnston, J C; Rempel, C; Sanders, C; Piggott, E; Maxwell, Y; Jaipersaud, K; Luknauth, R; Persaud, D; Rambaran, M; Levy, R D

    2016-09-01

    Georgetown Public Hospital Corporation (GPHC), a 600-bed publicly funded referral hospital in Georgetown, Guyana. To assess spirometry quality and diagnostic outcomes 2 years after the introduction of spirometry into routine clinical practice at GPHC. We performed a retrospective review of 476 consecutive spirometry assessments performed from November 2013 to November 2015. We assessed the proportion and trend of spirometry tests meeting acceptability criteria, along with diagnostic interpretations and spirometry laboratory referral patterns. Overall, 80.4% of the 454 initial spirometry measurements on unique patients met the acceptability criteria, with no significant change in the proportion of acceptable spirometry over the study period (P = 0.450). Of the 369 (81.3%) first tests considered interpretable, 139 (30.6%) were normal, 151 (33.3%) were obstructive, 54 (11.9%) were suggestive of a restrictive pattern, 25 (5.5%) were suggestive of a mixed disorder and 119 (26.2%) tests met the definition of reversibility. Over a 2-year period, high-quality spirometry was performed in GPHC, a publicly funded hospital in a middle-income country with no pre-existing specialised respiratory service.

  14. Clinicians' emotional responses and Psychodynamic Diagnostic Manual adult personality disorders: A clinically relevant empirical investigation.

    Science.gov (United States)

    Gazzillo, Francesco; Lingiardi, Vittorio; Del Corno, Franco; Genova, Federica; Bornstein, Robert F; Gordon, Robert M; McWilliams, Nancy

    2015-06-01

    The aim of this study is to explore the relationship between level of personality organization and type of personality disorder as assessed with the categories in the Psychodynamic Diagnostic Manual (PDM; PDM Task Force, 2006) and the emotional responses of treating clinicians. We asked 148 Italian clinicians to assess 1 of their adult patients in treatment for personality disorders with the Psychodiagnostic Chart (PDC; Gordon & Bornstein, 2012) and the Personality Diagnostic Prototype (PDP; Gazzillo, Lingiardi, & Del Corno, 2012) and to complete the Therapist Response Questionnaire (TRQ; Betan, Heim, Zittel-Conklin, & Westen, 2005). The patients' level of overall personality pathology was positively associated with helpless and overwhelmed responses in clinicians and negatively associated with positive emotional responses. A parental and disengaged response was associated with the depressive, anxious, and dependent personality disorders; an exclusively parental response with the phobic personality disorder; and a parental and criticized response with narcissistic disorder. Dissociative disorder evoked a helpless and parental response in the treating clinicians whereas somatizing disorder elicited a disengaged reaction. An overwhelmed and disengaged response was associated with sadistic and masochistic personality disorders, with the latter also associated with a parental and hostile/criticized reaction; an exclusively overwhelmed response with psychopathic patients; and a helpless response with paranoid patients. Finally, patients with histrionic personality disorder evoked an overwhelmed and sexualized response in their clinicians whereas there was no specific emotional reaction associated with the schizoid and the obsessive-compulsive disorders. Clinical implications of these findings were discussed. (c) 2015 APA, all rights reserved).

  15. Informativity of proteinograms as a clinical-diagnostic test at dispoteinemia in the age aspect

    Directory of Open Access Journals (Sweden)

    R. F. Yeriomenko

    2017-02-01

    Full Text Available The article analyzed dates of the usefulness of proteinograms as a clinical diagnostic test at dysproteinemia in age aspect. Established that proteinograms has  differences that depending on age, so these aspects should be considered in the diagnosis of certain pathological conditions in different age groups. Studying of children’s proteinograms in various pathological conditions indicates the appropriate changes in the fractional part of albumin and globulin, that characterized the development of inflammation and destruction of connective tissue. Besides diagnostic tests that help in the diagnosis, determine the stage of disease and the effectiveness of therapy is to study proteins "acute phase" and rheumatoid factor. Established the feasibility of proteinograms on the studying of dysproteinemia in different pathological conditions in adult age. It is found correlation between changes in protein fractions and stage of pathological process in connective tissue diseases (rheumatoid arthritis and systemic lupus erythema. At skin diseases, urinary, respiratory and hepatobiliary systems were recorded proteinograms changes depending on the damage of a system. Analysis of the results allows more accurate founded the diagnosis, determine the stage of the pathological process and evaluate the effectiveness of the pharmacotherapy.

  16. Fundamentals and commercial aspects of nanobiosensors in point-of-care clinical diagnostics.

    Science.gov (United States)

    Mahato, Kuldeep; Maurya, Pawan Kumar; Chandra, Pranjal

    2018-03-01

    Among various problems faced by mankind, health-related concerns are prevailing since long which are commonly found in the form of infectious diseases and different metabolic disorders. The clinical cure and management of such abnormalities are greatly dependent on the availability of their diagnoses. The conventional diagnostics used for such purposes are extremely powerful; however, most of these are limited by time-consuming protocols and require higher volume of test sample, etc. A new evolving technology called "biosensor" in this context shows an enormous potential for an alternative diagnostic device, which constantly compliments the conventional diagnoses. In this review, we have summarized different kinds of biosensors and their fundamental understanding with various state-of-the-art examples. A critical examination of different types of biosensing mechanisms is also reported highlighting the advantages of electrochemical biosensors for its great potentials in next-generation commercially viable modules. In recent years, a number of nanomaterials are extensively used to enhance not only the performance of biosensing mechanism, but also obtain robust, cheap, and fabrication-friendly durable mechanism. Herein, we have summarized the importance of nanomaterials in biosensing mechanism, their syntheses as well as characterization techniques. Subsequently, we have discussed the probe fabrication processes along with various techniques for assessing its analytical performances and potentials for commercial viability.

  17. Neonatal hemochromatosis and patent ductus venosus: clinical course and diagnostic pitfalls

    International Nuclear Information System (INIS)

    Tsai, Andy; Paltiel, Harriet J.; Sena, Laureen M.; Kim, Heung Bae; Fishman, Steven J.; Alomari, Ahmad I.

    2009-01-01

    Neonatal hemochromatosis is a rare metabolic disorder characterized by excessive iron deposition within the liver leading to hepatic failure and portal hypertension. We describe the clinical course and imaging findings in three infants with neonatal hemochromatosis associated with patent ductus venosus. We paid special attention to the diagnostic challenges encountered in these patients in order to emphasize some of the potential diagnostic pitfalls. We conducted a comprehensive search of our radiology database of the last 10 years (1999-2008) for the keywords ''neonatal hemochromatosis.'' Medical records and imaging studies of various modalities were reviewed. Three neonates were found to have neonatal hemochromatosis; all of them were associated with patent ductus venosus. Two of these patients were referred to our tertiary center for embolization of an inaccurately diagnosed hepatic vascular malformation. Two patients underwent successful liver transplantation and one died shortly after referral. The awareness and inclusion of neonatal hemochromatosis in the differential diagnosis of newborns with liver failure and patent ductus venosus has critical treatment implications. (orig.)

  18. Neonatal hemochromatosis and patent ductus venosus: clinical course and diagnostic pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, Andy; Paltiel, Harriet J.; Sena, Laureen M. [Children' s Hospital Boston and Harvard Medical School, Department of Radiology, Boston, MA (United States); Kim, Heung Bae; Fishman, Steven J. [Children' s Hospital Boston and Harvard Medical School, Department of Surgery, Boston, MA (United States); Alomari, Ahmad I. [Children' s Hospital Boston and Harvard Medical School, Department of Radiology, Boston, MA (United States); Children' s Hospital Boston, Division of Vascular and Interventional Radiology, Boston, MA (United States)

    2009-08-15

    Neonatal hemochromatosis is a rare metabolic disorder characterized by excessive iron deposition within the liver leading to hepatic failure and portal hypertension. We describe the clinical course and imaging findings in three infants with neonatal hemochromatosis associated with patent ductus venosus. We paid special attention to the diagnostic challenges encountered in these patients in order to emphasize some of the potential diagnostic pitfalls. We conducted a comprehensive search of our radiology database of the last 10 years (1999-2008) for the keywords ''neonatal hemochromatosis.'' Medical records and imaging studies of various modalities were reviewed. Three neonates were found to have neonatal hemochromatosis; all of them were associated with patent ductus venosus. Two of these patients were referred to our tertiary center for embolization of an inaccurately diagnosed hepatic vascular malformation. Two patients underwent successful liver transplantation and one died shortly after referral. The awareness and inclusion of neonatal hemochromatosis in the differential diagnosis of newborns with liver failure and patent ductus venosus has critical treatment implications. (orig.)

  19. How do clinicians actually use the Diagnostic and Statistical Manual of Mental Disorders in clinical practice and why we need to know more.

    Science.gov (United States)

    First, Michael B; Bhat, Venkat; Adler, David; Dixon, Lisa; Goldman, Beth; Koh, Steve; Levine, Bruce; Oslin, David; Siris, Sam

    2014-12-01

    The clinical use of the Diagnostic and Statistical Manual of Mental Disorders (DSM) is explicitly stated as a goal for both the DSM Fourth Edition and DSM Fifth Edition (DSM-5) revisions. Many uses assume a relatively faithful application of the DSM diagnostic definitions. However, studies demonstrate significant discrepancies between clinical psychiatric diagnoses with those made using structured interviews suggesting that clinicians do not systematically apply the diagnostic criteria. The limited information regarding how clinicians actually use the DSM raises important questions: a) How can the clinical use be improved without first having a baseline assessment? b) How can potentially significant shifts in practice patterns based on wording changes be assessed without knowing the extent to which the criteria are used as written? Given the American Psychiatric Association's plans for interim revisions to the DSM-5, the value of a detailed exploration of its actual use in clinical practice remains a significant ongoing concern and deserves further study including a number of survey and in vivo studies.

  20. Application of diagnostics to determine operational readiness of aged motor-operated valves

    International Nuclear Information System (INIS)

    Eissenberg, D.M.

    1987-01-01

    Oak Ridge National Laboratory (ORNL) has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor current signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment

  1. Application of diagnostics to determine motor-operated valve operational readiness

    International Nuclear Information System (INIS)

    Eissenberg, D.M.

    1986-01-01

    ORNL has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor curent signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment

  2. Morphological, clinical and radiological aspects in diagnostics of bronchopulmonary diseases and their complications in children with dysplasia of connective tissue

    Directory of Open Access Journals (Sweden)

    Palchik S.M.

    2016-06-01

    Full Text Available The article provides an overview of the literature devoted to study of radiological, morphological and clinical aspects of diagnostics of respiratory diseases and their complications in children with dysplasia of connective tissue nowadays. We made an analysis of the role of connective tissue disorders in pathogenesis of bronchopulmonary diseases. Theoretically was substantiated the importance of radiological methods in early diagnostics of this disease in children.

  3. The main challenges that remain in applying high-throughput sequencing to clinical diagnostics.

    Science.gov (United States)

    Loeffelholz, Michael; Fofanov, Yuriy

    2015-01-01

    Over the last 10 years, the quality, price and availability of high-throughput sequencing instruments have improved to the point that this technology may be close to becoming a routine tool in the diagnostic microbiology laboratory. Two groups of challenges, however, have to be resolved in order to move this powerful research technology into routine use in the clinical microbiology laboratory. The computational/bioinformatics challenges include data storage cost and privacy concerns, requiring analysis to be performed without access to cloud storage or expensive computational infrastructure. The logistical challenges include interpretation of complex results and acceptance and understanding of the advantages and limitations of this technology by the medical community. This article focuses on the approaches to address these challenges, such as file formats, algorithms, data collection, reporting and good laboratory practices.

  4. Carbon Nanotube Biosensors for Space Molecule Detection and Clinical Molecular Diagnostics

    Science.gov (United States)

    Han, Jie

    2001-01-01

    Both space molecule detection and clinical molecule diagnostics need to develop ultra sensitive biosensors for detection of less than attomole molecules such as amino acids for DNA. However all the electrode sensor systems including those fabricated from the existing carbon nanotubes, have a background level of nA (nanoAmp). This has limited DNA or other molecule detection to nA level or molecules whose concentration is, much higher than attomole level. A program has been created by NASA and NCI (National Cancer Institute) to exploit the possibility of carbon nanotube based biosensors to solve this problem for both's interest. In this talk, I will present our effort on the evaluation and novel design of carbon nanotubes as electrode biosensors with strategies to minimize background currents while maximizing signal intensity.The fabrication of nanotube electrode arrays, immobilization of molecular probes on nanotube electrodes and in vitro biosensor testing will also be discussed.

  5. Clinical diagnostic criteria for typical and atypical variants of Rett syndrome in children

    Directory of Open Access Journals (Sweden)

    S. Ya. Volgina

    2016-01-01

    Full Text Available Rett Syndrome is one of the most socially significant neuropsychiatric hereditary diseases in children. This syndrome is mainly found in girls: its frequency is 1:10000–15000. Currently mutations in X-linked gene MESR2 considered as the main cause of the syndrome. Diagnosis of typical and atypical variants of the syndrome is based on the use of clinical criteria, determining gene mutations МЕСР2, CDKL5 and FOXG1. In 2010, the Expert Consortium for Rett syndrome have revised the existing diagnostic criteria for the syndrome and come to a new consensus. If there is a regression of mental development for the diagnosis of Rett syndrome exemplary embodiment only four basic criteria for the diagnosis of atypical variant — two of the four main criteria, and five of the eleven additional criteria. 

  6. Diagnostic stability in bipolar disorder in clinical practise as according to ICD-10

    DEFF Research Database (Denmark)

    Kessing, Lars Vedel

    2005-01-01

    BACKGROUND: The diagnostic stability of the ICD-10 diagnosis of mania/bipolar disorder has not been investigated in clinical practice. METHODS: All patients who got a diagnosis of mania/bipolar disorder at least once in a period from 1994 to 2002 at outpatient treatment or at discharge from...... psychiatric hospitalisation in Denmark were identified in a nationwide register. RESULTS: Totally, 4116 patients got a diagnosis of mania/bipolar disorder at least once; among these, 2315 patients (56.2%) got the diagnosis at the first contact, whereas the remaining patients (43.8%) got the diagnosis at later...... and behavioural disorder due to psychoactive substance use and got a diagnosis of bipolar disorder later on. Especially younger but also female patients were at increased risk of delay of the diagnosis of bipolar disorder. LIMITATIONS: Only patients from psychiatric settings were included. CONCLUSIONS: Clinicians...

  7. Isolated clinic hypertension: diagnostic criteria based on 24-h blood pressure definition.

    Science.gov (United States)

    Vinyoles, Ernest; Rodriguez-Blanco, Teresa; de la Sierra, Alejandro; Felip, Angela; Banegas, José R; de la Cruz, Juan J; Gorostidi, Manuel; Sobrino, Javier; Segura, Julián; Roca-Cusachs, Alex; Ruilope, Luís M

    2010-12-01

    The use of diagnostic criteria based on 24-h ambulatory blood pressure (BP) values could improve prognostic value by incorporating night BP, minimize biases and improve the diagnostic reproducibility of isolated clinic hypertension (ICH). We estimate the 24-h BP cut-off points that best discriminate and predict the two diagnostic thresholds of mean daytime BP for ICH (135/85 and 130/80 mmHg). Cross-sectional, comparative, multicentre study in 6176 untreated hypertensive patients, whose BP was measured by ambulatory BP monitoring. ICH was defined with an office BP of ≥140/≥90 mmHg and a daytime BP of <135/<85 mmHg (ICH1) or <130/80 mmHg (ICH2). Sensitivity, specificity, positive likelihood ratio (LR+), odds ratio (OR), error rate, predictive values, κ values and 95% confidence interval were calculated for each possible cut-off point for ICH1 and ICH2. One thousand eight hundred and seven patients (29.2%) and 960 patients (15.5%) met ICH1 and ICH2 criteria, respectively. The 24-h BP cut-off points that best predict ICH1 and ICH2 are less than 132/82 mmHg (sensitivity: 93.6%, specificity: 94.3%, LR+: 16.6, OR: 1367.1, error rate: 5.9, κ 0.86) and less than 127/77 mmHg (sensitivity: 90.8%, specificity: 97.4%, LR+: 34.6, OR: 1041.5, error rate: 3.6,κ 0.86), respectively. These values achieved the best balance of sensitivity and specificity, together with the highest values of LR+ and OR and the lowest error rate. The 24-h BP cut-off point that best predicts the daytime criterion of less than 135/85 and less than 130/80 mmHg are 132/82 and 127/77 mmHg, respectively. These 24-h cut-off points may add value to ambulatory blood pressure monitoring for both diagnostic and management future decisions.

  8. A Review of the Giant Protein Titin in Clinical Molecular Diagnostics of Cardiomyopathies

    Directory of Open Access Journals (Sweden)

    Marta Gigli

    2016-07-01

    Full Text Available Titin (TTN is known as the largest sarcomeric protein that resides within the heart muscle. Due to alternative splicing of TTN the heart expresses two major isoforms (N2B and N2BA that incorporate four distinct regions termed the Z-line, I-band, A-band, and M-line. Next-generation sequencing allows a large number of genes to be sequenced simultaneously and provides the opportunity to easily analyze giant genes such as TTN. Mutations in the TTN gene can cause cardiomyopathies, in particular dilated cardiomyopathy (DCM. DCM is the most common form of cardiomyopathy and it is characterized by systolic dysfunction and dilation of the left ventricle. TTN truncating variants have been described as the most common cause of DCM while the real impact of TTN missense variants in the pathogenesis of DCM is still unclear. In a recent population screening study, rare missense variants potentially pathogenic based on bioinformatic filtering represented only 12.6% of the several hundred rare TTN missense variants found, suggesting that missense variants are very common in TTN and frequently benign. The aim of this review is to understand the clinical role of TTN mutations in DCM and in other cardiomyopathies. Whereas TTN truncations are common in DCM, there is evidence that TTN truncations are rare in the HCM phenotype. Furthermore TTN mutations can also cause arrhythmogenic right ventricular cardiomyopathy (ARVC with distinct clinical features and outcomes. Finally, the identification of a rare missense variant in TTN cosegregating with the restrictive cardiomyopathy (RCM phenotype suggests that TTN is a novel gene in this disease. Clinical diagnostic testing is currently able to analyze over 100 cardiomyopathy genes, including TTN, however, the size and presence of extensive genetic variation in TTN presents clinical challenges in determining significant disease-causing mutations. This review discusses the current knowledge of TTN genetic variations in

  9. NONTUBERCULOUS MYCOBACTERIOSES: EPIDEMIOLOGY, CLINIC AND POSSIBILITIES OF LABORATORY DIAGNOSTICS IN MODERN CONDITIONS

    Directory of Open Access Journals (Sweden)

    Shevchenko OS

    2017-03-01

    Full Text Available Introduction. Today there are more than 150 species of nontuberculous mycobacteria (NTMB known, of which 99 were registered in Europe. Due to the similar clinical picture with tuberculosis, mycobacterioses are difficult to diagnose and often occur with TB as a mixed infection. Also, there are cases of NTMB detection in the sputum of persons previously suffered with tuberculosis, which can lead to a false diagnosis of recurrent disease. Currently, the role of atypical mycobacteria in human pathology is increasing. Atypical mycobacteria are characterized by a wide spectrum of sustainability and potential pathogenicity to humans and animals. It is generally accepted that the reservoir of infection are animals and the environment (water, soil. NTMB presence in water can lead to the erroneous diagnosis of mycobacteriosis due to laboratory contamination of samples with nontuberculous mycobacteria from the outside. Moreover recently it has been found the possibility of transferring NTMB from person to person on the background of existing lung disease. For many types of infections reservoir still has not been found. Aim of this work was to study identified in the Kharkiv region cases of non-tuberculous mycobacterioses, features of their clinical manifestations and laboratory diagnostic options. Materials and Methods. We examined 32 patients (25 men and 7 women, residents of Kharkiv and Kharkiv region, Ukraine, who were diagnosed with "non-tuberculous mycobacteriosis of lungs" during 2014-2016. Patients were examined with routine diagnostic algorithm for TB. Nontuberculous mycobacteriosis was diagnosed on the basis of NTMB growth in BACTEC system, after which the diagnosis was verified by the following criteria: 1. Smear: the absence of formation of Cord-factor (in the smear NTMB are located scattering; 2. Negative immunoassay (ID-test; 3. Negative GeneXpert MTB/RIF Then non-tuberculous mycobacteria were identificated by investigation on solid media

  10. Early diagnosis of amyotrophic lateral sclerosis mimic syndromes: pros and cons of current clinical diagnostic criteria.

    Science.gov (United States)

    Cortés-Vicente, Elena; Pradas, Jesús; Marín-Lahoz, Juan; De Luna, Noemi; Clarimón, Jordi; Turon-Sans, Janina; Gelpí, Ellen; Díaz-Manera, Jordi; Illa, Isabel; Rojas-Garcia, Ricard

    2017-08-01

    To describe the frequency and clinical characteristics of patients referred to a tertiary neuromuscular clinic as having amyotrophic lateral sclerosis (ALS) but who were re-diagnosed as having an ALS mimic syndrome, and to identify the reasons that led to the revision of the diagnosis. We reviewed the final diagnosis of all patients prospectively registered in the Sant Pau-MND register from 1 January 2004 to 31 December 2015. A detailed clinical evaluation and a clinically-guided electrophysiological study were performed at first evaluation. Twenty of 314 (6.4%) patients included were re-diagnosed as having a condition other than ALS, in 18 cases already at first evaluation. An alternative specific diagnosis was identified in 17 of those 20, consisting of a wide range of conditions. The main finding leading to an alternative diagnosis was the result of the electrophysiological study. Fifty per cent did not fulfil the El Escorial revised criteria (EECr) for ALS. The most common clinical phenotype at onset in patients with ALS mimic syndromes was progressive muscular atrophy (PMA). Misdiagnosing ALS is still a common problem. Early identification of ALS mimic syndromes is possible based on atypical clinical features and a clinically-guided electrophysiological study. Patients should be attended in specialised centres. The application of EECr helps to identify ALS misdiagnoses.

  11. Diagnostic Accuracy of Clinical Methods for Detection of Diabetic Sensory Neuropathy

    International Nuclear Information System (INIS)

    Arshad, A. R.; Alvi, K. Y.

    2016-01-01

    Objective: To determine the accuracy of clinical methods for detection of sensory neuropathy as compared to biothesiometry. Study Design: Cross-sectional analytical study. Place and Duration of Study: 1 Mountain Medical Battalion, Azad Kashmir, from October 2013 to September 2014. Methodology: Patients with type 2 diabetes were enrolled by convenience sampling. Exclusion criteria included other identifiable causes of neuropathy, extensive ulceration of feet, amputated feet, those on treatment for neuropathy and unwilling patients. Average of 3 vibration perception threshold values measured with a biothesiometer on distal hallux was calculated. Ten gm monofilament was used to examine touch sensation over dorsal surfaces of great toes. Vibration sensation was checked over the tips of great toes using 128Hz tuning fork. Ankle jerks were checked bilaterally. Result: Neuropathy (vibration perception threshold > 25 volts) was present in 34 (21.12 percentage) out of 161 patients and 93 (57.76 percentage) were symptomatic. Measures of diagnostic accuracy for monofilament, tuning fork and ankle jerks were: sensitivity 41.18 percentage, 55.88 percentage and 64.71 percentage; specificity 92.91 percentage, 93.70 percentage and 80.31 percentage; positive predictive value (PPV) 60.87 percentage, 70.37 percentage and 46.81 percentage; negative predictive value (NPV) 85.51 percentage, 88.81 percentage and 89.47 percentage; and, diagnostic accuracy 81.99 percentage, 85.71 percentage and 77.02 percentage, respectively. Values for any 1 positive sign, any 2 positive signs or all 3 positive signs were: sensitivity 35.29 percentage, 14.71 percentage and 32.35 percentage; specificity 81.89 percentage, 93.70 percentage and 99.21 percentage; PPV 34.29 percentage, 38.46 percentage and 91.67 percentage; NPV 82.54 percentage, 80.41 percentage and 84.56 percentage; and, diagnostic accuracy 72.05 percentage, 77.02 percentage and 85.09 percentage, respectively. Conclusion: Clinical methods are

  12. Principles and applications of polymerase chain reaction in medical diagnostic fields: a review.

    Science.gov (United States)

    Valones, Marcela Agne Alves; Guimarães, Rafael Lima; Brandão, Lucas André Cavalcanti; de Souza, Paulo Roberto Eleutério; de Albuquerque Tavares Carvalho, Alessandra; Crovela, Sergio

    2009-01-01

    Recent developments in molecular methods have revolutionized the detection and characterization of microorganisms in a broad range of medical diagnostic fields, including virology, mycology, parasitology, microbiology and dentistry. Among these methods, Polymerase Chain Reaction (PCR) has generated great benefits and allowed scientific advancements. PCR is an excellent technique for the rapid detection of pathogens, including those difficult to culture. Along with conventional PCR techniques, Real-Time PCR has emerged as a technological innovation and is playing an ever-increasing role in clinical diagnostics and research laboratories. Due to its capacity to generate both qualitative and quantitative results, Real-Time PCR is considered a fast and accurate platform. The aim of the present literature review is to explore the clinical usefulness and potential of both conventional PCR and Real-Time PCR assays in diverse medical fields, addressing its main uses and advances.

  13. Quantifying heterogeneity attributable to polythetic diagnostic criteria: theoretical framework and empirical application.

    Science.gov (United States)

    Olbert, Charles M; Gala, Gary J; Tupler, Larry A

    2014-05-01

    Heterogeneity within psychiatric disorders is both theoretically and practically problematic: For many disorders, it is possible for 2 individuals to share very few or even no symptoms in common yet share the same diagnosis. Polythetic diagnostic criteria have long been recognized to contribute to this heterogeneity, yet no unified theoretical understanding of the coherence of symptom criteria sets currently exists. A general framework for analyzing the logical and mathematical structure, coherence, and diversity of Diagnostic and Statistical Manual diagnostic categories (DSM-5 and DSM-IV-TR) is proposed, drawing from combinatorial mathematics, set theory, and information theory. Theoretical application of this framework to 18 diagnostic categories indicates that in most categories, 2 individuals with the same diagnosis may share no symptoms in common, and that any 2 theoretically possible symptom combinations will share on average less than half their symptoms. Application of this framework to 2 large empirical datasets indicates that patients who meet symptom criteria for major depressive disorder and posttraumatic stress disorder tend to share approximately three-fifths of symptoms in common. For both disorders in each of the datasets, pairs of individuals who shared no common symptoms were observed. Any 2 individuals with either diagnosis were unlikely to exhibit identical symptomatology. The theoretical and empirical results stemming from this approach have substantive implications for etiological research into, and measurement of, psychiatric disorders.

  14. CT colonography after colostomy - clinical application and technical feasibility

    International Nuclear Information System (INIS)

    Nedevska, A.

    2013-01-01

    Full text:Introduction: The aim of this study was to evaluate the clinical application and technical implementation of computed tomographic (CT ) colonoscopy in patients undergoing sigmoid or rectal resection and following sigmoid colostomy in the course of standard diagnostic postoperative follow-up and prior to the reconstructive colon surgery. Materials and Methods: The study included 48 patients who underwent anterior abdomen-perineal or rectal resection and subsequent sigmoid colostomy in case of sigma or rectum carcinoma. The pre-procedure bowel preparation included a full colon cleansing and barium-based fecal tagging. The balloon catheter (18 F) is placed in the colonic stoma. The balloon is insufflated with 15-30 ml saline or air. The balloon was gently pulled until opening of the stoma has been closed completely. In 15 patients, a second catheter was placed in the remaining rectum. Contrast scanning in supination was done for all patients. An additional scanning in left and right lateral position was necessary for 9 patients. Results: All studies were carried out without any major complications. All patients tolerated the intubation and insufflation of air into the intestinal lumen. Two patients (4%) have evaluated the examination as uncomfortable. In 6 patients (12.5 %) it was impossible to evaluate the intestinal segments because due to a collapse of the wall. Five of them were localized in the descending colon. In 5 patients there was a significant amount of residual intestinal contents. The fecal tagging and intravenous contrast enhancing allowed the assessment of these intestinal segments. The rectal residue was correctly assessed in all patients in terms of length, position and wall changes. Conclusion: CT colonoscopy is applicable after sigmostoma in patients with abdomen-perineal and anterior rectal resection. Further in-depth studies are needed to determine the clinical indications and reliability of the method

  15. Clinical application of fluorescence in situ hybridization for prenatal diagnosis

    Directory of Open Access Journals (Sweden)

    Shu-fang JIANG

    2012-07-01

    Full Text Available Objective To establish and optimize the procedures of fluorescence in situ hybridization(FISH), and evaluate its clinical value in rapid prenatal diagnosis of fetal numerical abnormality of chromosomes 21, 18, 13, X, Y. Methods Amniotic fluid or fetal blood was sampled by routine invasive procedures. After the amniotic fluid cells or fetal blood cells were separated and sequentially processed with hypotonic solution, fixation solution, smear and high temperature, they were hybridized in situ with two panels of specific fluorescence probes to detect numerical abnormality of chromosomes 21, 18, 13, X, Y. All the samples were also cultured and analyzed for their karyotype by conventional methods. Results When it was used as a diagnostic criterion of chromosomal number that the fluorescence signals were observed in ≥90% cells, GLP 13/GLP 21 probe panel showed 2 green/2 red fluorescence signals and CSP18/CSP X/CSP Y probe panel showed 2 blue/2 yellow (female or 2 blue/1 yellow/1 red fluorescence signals (male under normal condition. The test reports of all 196 cases were sent out in 72-96 hours, and 7 cases of Down syndrome, 2 cases of trisomy 18 and 1 case of sex chromosomal numerical abnormality were detected, which were accordant with karyotype analysis results reported one month later. Conclusions FISH has potential for clinical application, and is applicable to rapid prenatal diagnosis of fetal numerical abnormality of chromosomes 21, 18, 13, X, Y. The rapid FISH, together with conventional karyotyping, offer a valuable means for prenatal diagnosis of fetal aneuploidies.

  16. Advance of nuclear cardiology in clinical application

    International Nuclear Information System (INIS)

    Shi Hongcheng

    2007-01-01

    Nuclear cardiology has make a little bit progress in the past year. Both nuclear cardiology and other cardiac imaging have its own advantage and disadvantage in the diagnostic of coronary artery disease. And the relationship of them is complementary but not instead of each other. Nuclear cardiology provides a one-stop shop for diagnosis, risk stratification, and management of coronary artery disease. Nuclear cardiology plays a very important role in the diagnostic of coronary artery disease in early stage in the special group of people. (authors)

  17. MR urography: examination techniques and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Adam, G.B.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2001-03-01

    Modern MR urography is performed on the basis of two different imaging strategies, which can be used complementarily to cover almost all aspects in the diagnosis of upper urinary tract diseases. The first technique utilizes unenhanced, heavily T2-weighted pulse sequences to obtain static-fluid images of the urinary tract. T2-weighted MR urograms have proved to be excellent in the visualization of the markedly dilated urinary tract, even if the renal excretory function is quiescent. Static-fluid MR urography is less suitable for imaging of disorders that occur in the nondilated collecting system. The second MR urography technique is analogous to the methodology of conventional intravenous pyelography and is, therefore, designated as excretory MR urography. For this purpose, a non-nephrotoxic gadolinium chelate is intravenously administered and after its renal excretion, the gadolinium-enhanced urine is visualized using fast T1-weighted gradient-echo sequences. The combination of gadolinium and low-dose furosemide (5-10 mg) is the key for achieving a uniform distribution of the contrast material inside the entire urinary tract and, secondly, to avoid high endoluminal gadolinium concentrations, which cause signal loss of the urine due to T2{sup *} effects. Gadolinium excretory MR urography allows to obtain high-quality images of both nondilated and obstructed urinary tracts in patients with normal or moderately impaired renal function. This article reviews the principles of T2- and T1-weighted MR urography in detail and informs how to use these techniques safely in potential clinical applications such as chronic urolithiasis, intrinsic and extrinsic tumor diseases, and congenital anomalies. Magnetic resonance urography performed in combination with standard MR imaging offers a potential to reduce the need for invasive retrograde pyelography. Although the economic aspect is still problematic, it is obvious that MR urography will continue to increase its role in

  18. Prehospital Ultrasound in Trauma: A Review of Current and Potential Future Clinical Applications

    Directory of Open Access Journals (Sweden)

    Tharwat El Zahran

    2018-01-01

    Full Text Available Ultrasound (US is an essential tool for evaluating trauma patients in the hospital setting. Many previous in-hospital studies have been extrapolated to out of hospital setting to improve diagnostic accuracy in prehospital and austere environments. This review article presents the role of prehospital US in blunt and penetrating trauma management with emphasis on its current clinical applications, challenges, and future implications of such use.

  19. Clinical and diagnostic methods for evaluation of sharp foreign body syndrome in buffaloes

    Directory of Open Access Journals (Sweden)

    Nasr-Eldin M. Aref

    2013-06-01

    Full Text Available Aim: The present study was designed to evaluate clinically and under laboratory condition the sharp foreign body syndrome (SFBS in buffaloes with special emphasis on the diagnostic value of radiography, ultrasonography and blood gases and acidbase balance. Materials and Methods: 196 buffaloes with a history of anorexia, reduction of milk production and no response to previous medical treatment were included in the present study. These animals were subjected to clinical and radiographical examinations. Positive cases for SFBS were further evaluated by sonography, hemato-biochemical and blood gas and acid base balance analysis.Results: Out of 196 admitted cases, 49 (25% cases were confirmed as SFBS by clinical and radiographical examination. Positive cases were subsequently divided into two main categories (complicated and non complicated according to radiographical and sonographical findings. SFBS with no complication was diagnosed in 16 cases while 33 cases showed various degrees of complication including reticular adhesion (abdominal and diaphragmatic, n= 23, diaphragmatic hernia (n = 6 and traumatic pericarditis (n = 4. Leukocytosis, hyperprotenemia and increased activity of AST and ALT were of additional values in the diagnosis of SFBS. A consistent finding of primary metabolic alkalosis was recorded in all cases except one with advanced traumatic pericarditis that showed metabolic acidosis. Conclusion: While there is no substitution for clinical examination, using of ultrasonography and radiography simultaneously are essential for proper evaluation and differentiation between various sequelae of SFBS in buffaloes. Radiography is an efficient tool for visualization of metallic foreign body while ultrasonography is an excellent device in assessing fibrinous deposits. Hemato-biochemical and blood gases and acid base balance are of additional values in discriminating between various outcomes of SFBS.

  20. Diagnostic evaluation and management of chronic thromboembolic pulmonary hypertension: A clinical practice guideline

    Science.gov (United States)

    Mehta, Sanjay; Helmersen, Doug; Provencher, Steeve; Hirani, Naushad; Rubens, Fraser D; De Perrot, Marc; Blostein, Mark; Boutet, Kim; Chandy, George; Dennie, Carole; Granton, John; Hernandez, Paul; Hirsch, Andrew M; Laframboise, Karen; Levy, Robert D; Lien, Dale; Martel, Simon; Shoemaker, Gerard; Swiston, John; Weinkauf, Justin

    2010-01-01

    BACKGROUND Pulmonary embolism is a common condition. Some patients subsequently develop chronic thromboembolic pulmonary hypertension (CTEPH). Many care gaps exist in the diagnosis and management of CTEPH patients including lack of awareness, incomplete diagnostic assessment, and inconsistent use of surgical and medical therapies. METHODS A representative interdisciplinary panel of medical experts undertook a formal clinical practice guideline development process. A total of 20 key clinical issues were defined according to the patient population, intervention, comparator, outcome (PICO) approach. The panel performed an evidence-based, systematic, literature review, assessed and graded the relevant evidence, and made 26 recommendations. RESULTS Asymptomatic patients postpulmonary embolism should not be screened for CTEPH. In patients with pulmonary hypertension, the possibility of CTEPH should be routinely evaluated with initial ventilation/ perfusion lung scanning, not computed tomography angiography. Pulmonary endarterectomy surgery is the treatment of choice in patients with surgically accessible CTEPH, and may also be effective in CTEPH patients with disease in more ‘distal’ pulmonary arteries. The anatomical extent of CTEPH for surgical pulmonary endarterectomy is best assessed by contrast pulmonary angiography, although positive computed tomography angiography may be acceptable. Novel medications indicated for the treatment of pulmonary hypertension may be effective for selected CTEPH patients. CONCLUSIONS The present guideline requires formal dissemination to relevant target user groups, the development of tools for implementation into routine clinical practice and formal evaluation of the impact of the guideline on the quality of care of CTEPH patients. Moreover, the guideline will be updated periodically to reflect new evidence or clinical approaches. PMID:21165353

  1. Telepsychiatry clinical decision support system used by non-psychiatrists in remote areas: Validity & reliability of diagnostic module

    Science.gov (United States)

    Malhotra, Savita; Chakrabarti, Subho; Shah, Ruchita; Sharma, Minali; Sharma, Kanu Priya; Malhotra, Akanksha; Upadhyaya, Suneet K.; Margoob, Mushtaq A.; Maqbool, Dar; Jassal, Gopal D.

    2017-01-01

    Background & objectives: A knowledge-based, logically-linked online telepsychiatric decision support system for diagnosis and treatment of mental disorders was developed and validated. We evaluated diagnostic accuracy and reliability of the application at remote sites when used by non-psychiatrists who underwent a brief training in its use through video-conferencing. Methods: The study was conducted at a nodal telepsychiatry centre, and three geographically remote peripheral centres. The diagnostic tool of application had a screening followed by detailed criteria-wise diagnostic modules for 18 psychiatric disorders. A total of 100 consecutive consenting adult outpatients attending remote telepsychiatry centres were included. To assess inter-rater reliability, patients were interviewed face to face by non-specialists at remote sites using the application (active interviewer) and simultaneously on online application via video-conferencing by a passive assessor at nodal centre. Another interviewer at the nodal centre rated the patient using Mini-International Neuropsychiatric Interview (MINI) for diagnostic validation. Results: Screening sub-module had high sensitivity (80-100%), low positive predictive values (PPV) (0.10-0.71) but high negative predictive value (NPV) (0.97-1) for most disorders. For the diagnostic sub-modules, Cohen's kappa was >0.4 for all disorders, with kappa of 0.7-1.0 for most disorders. PPV and NPV were high for most disorders. Inter-rater agreement analysis revealed kappa >0.6 for all disorders. Interpretation & conclusions: Diagnostic tool showed acceptable to good validity and reliability when used by non-specialists at remote sites. Our findings show that diagnostic tool of the telepsychiatry application has potential to empower non-psychiatrist doctors and paramedics to diagnose psychiatric disorders accurately and reliably in remote sites. PMID:29265020

  2. Clinical application of PET in abdominal cancers

    International Nuclear Information System (INIS)

    Choi, Chang Woon

    2002-01-01

    Clinical application of positron emission tomography (PET) is rapidly increasing for the detection and staging of cancer at whole-body studies performed with the glucose analogue tracer 2-[fluorine-18]fluoro-2-deoxy-D-glucose (FG). Although FDG PET cannot match the anatomic resolution of conventional imaging techniques in the liver and the other abdominal organs, it is particularly useful for identification and characterization of the entire body simultaneously. FDG PET can show foci of metastatic disease that may not be apparent at conventional anatomic imaging and can aid in the characterizing of indeterminate soft-tissue masses. Most abdominal cancer requires surgical management. FGD PET can improve the selection of patients for surgical treatment and thereby reduce the morbidity and mortality associated with inappropriate surgery. FDG PET is also useful for the early detection of recurrence and the monitoring of therapeutic effect. The abdominal cancers, such as gastroesophageal cancer, colorectal cancer, liver cancer and pancreatic cancer, are common malignancies in Korea, and PET is one of the most promising and useful methodologies for the management of abdominal cancers

  3. Whole body detectors for clinical applications

    International Nuclear Information System (INIS)

    Silar, J.

    The requirements are presented on the parameters of whole-body detectors suitable for clinical retention assays and the detector-patient configuration described. A whole-body detector was developed with an axial configuration of two pairs of large-volume scintillation detectors with NaI(Tl) crystals. One pair is placed under the bed, the other above the bed on which the patient is being examined. The axes of the crystals are located at a distance of 90 cm apart. The field of vision of the detector is described for the application of a 137 Cs source in the air and in a 24 cm layer of water. The positive characteristics of the detector are listed as being homogeneous sensitivity, energy resolution, long-term stability of signal pulse amplitude and average pulse rate in the integral mode. The results obtained show that the detector may be used to evaluate the level of contamination of persons by gamma emitters within the region of approximately 800 Bq to 74 MBq. The error in converting the number of signal pulses in the integral mode does not exceed 50% for gamma emitters with a photon energy above 30O keV. (J.B.)

  4. [Diagnostic imaging of high-grade astrocytoma: heterogeneity of clinical manifestation, image characteristics, and histopathological findings].

    Science.gov (United States)

    Okajima, Kaoru; Ohta, Yoshio

    2012-10-01

    Recent developments in diagnostic radiology, which have enabled accurate differential diagnoses of brain tumors, have been well described in the last three decades. MR and PET imaging can also provide information to predict histological grades and prognoses that might influence treatment strategies. However, high-grade astrocytomas consist of many different subtypes that are associated with different imaging and histological characteristics. Hemorrhage and necrosis results in a variety of imaging features, and infiltrative tumor growth entrapping normal neurons may cause different clinical manifestations. We reviewed patients with high-grade astrocytomas that showed various imaging characteristics, with special emphasis on initial symptoms and histological features. Clinicopathological characteristics of astrocytomas were also compared with other malignant tumors. Neurological deficits were not notable in patients with grade 3-4 astrocytomas when they showed infiltrative tumor growth, while brain metastases with compact cellular proliferation caused more neurological symptoms. Infiltrative tumors did not show any enhancing masses on MR imaging, but these tumors may show intratumor heterogeneity. Seizures were reported to be more frequent in low-grade glioma and in secondary glioblastoma. Tumor heterogeneity was also reported in molecular genetic profile, and investigators identified some subsets of astrocytomas. They investigated IHD1/2 mutation, EGFR amplification, TP53 mutation, Ki-67 index, etc. In summary, high-grade astrocytomas are not homogenous groups of tumors, and this is associated with the heterogeneity of clinical manifestation, image characteristics, and histopathological findings. Molecular studies may explain the tumor heterogeneity in the near future.

  5. Clinical features, diagnostic criteria, and management of Coffin-Siris syndrome.

    Science.gov (United States)

    Vergano, Samantha S; Deardorff, Matthew A

    2014-09-01

    Coffin-Siris syndrome (OMIM#135900) is a multiple congenital anomaly syndrome classically characterized by hypo- or aplasia of the fifth digit nails or phalanges, as well as coarse facial features, sparse scalp hair, and moderate to severe cognitive and/or developmental delay. The recent identification of molecular etiologies has served to effectively characterize a large set of patients who have been described with Coffin-Siris between the time of its initial description and the present. However, despite recent advances, a number of patients who traditionally fit the diagnosis have yet to have identified causes. This could be due to patients who lie outside the defined phenotype, or alternatively, to additional as yet unidentified genes which may play roles. Here we outline the range of clinical features described in the broader diagnostic category, review the continuing phenotypic challenges and note those subsets of patients for whom molecular causes have yet to be clarified. Finally, we discuss recommendations for clinical management of these individuals. © 2014 Wiley Periodicals, Inc.

  6. Diagnostic and clinical observation on the infectious bronchitis virus strain Q1 in Italy

    Directory of Open Access Journals (Sweden)

    Anna Toffan

    2013-12-01

    Full Text Available This paper describes the diagnostic and clinical observations of an infectious bronchitis virus (IBV variant, referred to as Q1, in clinically ill chickens in Italy. This IBV variant was described for the first time in 1998 in China. In the autumn of 2011 it caused a small-scale epidemic in non-vaccinated meat chickens in farms located in Northern Italy. The disease was characterized by increased mortality, kidney lesions and proventriculitis. Histopatological observations confirmed the nephritis and described an unusual erosive/necrotic proventriculitis with infiltration of lymphocytes, plasma cells and heterophils, as well as fibroplasia in the lamina propria. Despite these findings and the isolation of the Q1 IB virus directly from proventricular tissue, further studies are necessary to confirm the role of this IBV strain in the development of proventricular lesions. Phylogenetic analysis revealed that all the IBV isolates were very similar and probably had a common origin. The IBV Q1 variant appears to be now endemic in the North of Italy and at times it is detected in vaccinated backyard and commercial broiler farms. The importance of continuous monitoring in controlling the spread of known or emerging IBV variants is underlined.

  7. Quality control in diagnostic radiology: software (Visual Basic 6) and database applications

    International Nuclear Information System (INIS)

    Md Saion Salikin; Muhammad Farid Abdul Khalid

    2002-01-01

    Quality Assurance programme in diagnostic Radiology is being implemented by the Ministry of Health (MoH) in Malaysia. Under this program the performance of an x-ray machine used for diagnostic purpose is tested by using the approved procedure which is commonly known as Quality Control in diagnostic radiology. The quality control or performance tests are carried out b a class H licence holder issued the Atomic Energy Licensing Act 1984. There are a few computer applications (software) that are available in the market which can be used for this purpose. A computer application (software) using Visual Basics 6 and Microsoft Access, is being developed to expedite data handling, analysis and storage as well as report writing of the quality control tests. In this paper important features of the software for quality control tests are explained in brief. A simple database is being established for this purpose which is linked to the software. Problems encountered in the preparation of database are discussed in this paper. A few examples of practical usage of the software and database applications are presented in brief. (Author)

  8. A centrifugal microfluidic platform for point-of-care diagnostic applications

    Directory of Open Access Journals (Sweden)

    Suzanne Hugo

    2014-02-01

    Full Text Available Microfluidic systems enable precise control over tiny volumes of fluid in a compact and low-cost form, thus providing the ideal platform on which to develop point-of-care diagnostic solutions. Centrifugal microfluidic systems, also referred to as lab-on-a-disc or lab-on-a-CD systems, provide a particularly attractive solution for the implementation of microfluidic point-of-care diagnostic solutions as a result of their simple and compact instrumentation, as well as their functional diversity. Here we detail the implementation of a centrifugal microfluidic platform the first of its kind in South Africa as a foundation for the development of point-of-care diagnostic applications for which both the need and impact is great. The centrifugal microfluidic platform consists of three main components: a microfluidic disc device similar in size and shape to a CD, a system for controlling fluid flow on the device, and a system for recording the results obtained. These components have been successfully implemented and tested. Preliminary test results show that microfluidic functions such as pumping and valving of fluids can be successfully achieved, as well as the generation of monodisperse microfluidic droplets, providing a complete centrifugal microfluidic platform and the building blocks on which to develop a variety of applications, including point-of-care diagnostics. The lab-on-a-disc platform has the potential to provide new diagnostic solutions at the point-of-need in health- and industry-related areas. This paves the way for providing resource limited areas with services such as improved, decentralised health-care access or water-quality monitoring, and reduced diagnosis times at a low cost.

  9. Machine learning classification with confidence: application of transductive conformal predictors to MRI-based diagnostic and prognostic markers in depression.

    Science.gov (United States)

    Nouretdinov, Ilia; Costafreda, Sergi G; Gammerman, Alexander; Chervonenkis, Alexey; Vovk, Vladimir; Vapnik, Vladimir; Fu, Cynthia H Y

    2011-05-15

    There is rapidly accumulating evidence that the application of machine learning classification to neuroimaging measurements may be valuable for the development of diagnostic and prognostic prediction tools in psychiatry. However, current methods do not produce a measure of the reliability of the predictions. Knowing the risk of the error associated with a given prediction is essential for the development of neuroimaging-based clinical tools. We propose a general probabilistic classification method to produce measures of confidence for magnetic resonance imaging (MRI) data. We describe the application of transductive conformal predictor (TCP) to MRI images. TCP generates the most likely prediction and a valid measure of confidence, as well as the set of all possible predictions for a given confidence level. We present the theoretical motivation for TCP, and we have applied TCP to structural and functional MRI data in patients and healthy controls to investigate diagnostic and prognostic prediction in depression. We verify that TCP predictions are as accurate as those obtained with more standard machine learning methods, such as support vector machine, while providing the additional benefit of a valid measure of confidence for each prediction. Copyright © 2010 Elsevier Inc. All rights reserved.

  10. The validation and clinical implementation of BRCAplus: a comprehensive high-risk breast cancer diagnostic assay.

    Directory of Open Access Journals (Sweden)

    Hansook Kim Chong

    Full Text Available Breast cancer is the most commonly diagnosed cancer in women, with 10% of disease attributed to hereditary factors. Although BRCA1 and BRCA2 account for a high percentage of hereditary cases, there are more than 25 susceptibility genes that differentially impact the risk for breast cancer. Traditionally, germline testing for breast cancer was performed by Sanger dideoxy terminator sequencing in a reflexive manner, beginning with BRCA1 and BRCA2. The introduction of next-generation sequencing (NGS has enabled the simultaneous testing of all genes implicated in breast cancer resulting in diagnostic labs offering large, comprehensive gene panels. However, some physicians prefer to only test for those genes in which established surveillance and treatment protocol exists. The NGS based BRCAplus test utilizes a custom tiled PCR based target enrichment design and bioinformatics pipeline coupled with array comparative genomic hybridization (aCGH to identify mutations in the six high-risk genes: BRCA1, BRCA2, PTEN, TP53, CDH1, and STK11. Validation of the assay with 250 previously characterized samples resulted in 100% detection of 3,025 known variants and analytical specificity of 99.99%. Analysis of the clinical performance of the first 3,000 BRCAplus samples referred for testing revealed an average coverage greater than 9,000X per target base pair resulting in excellent specificity and the sensitivity to detect low level mosaicism and allele-drop out. The unique design of the assay enabled the detection of pathogenic mutations missed by previous testing. With the abundance of NGS diagnostic tests being released, it is essential that clinicians understand the advantages and limitations of different test designs.

  11. Clinical performance of dual-source computerized tomography (DSCT) in primary diagnostics of coronary heart diseases

    International Nuclear Information System (INIS)

    Brunner, H.; Froehner, S.; Wagner, M.; Schmitt, R.; Brunn, J.; Gietzen, F.H.; Kerber, S.

    2008-01-01

    Dual-source-CT-technology (DSCT) improves temporal resolution of cardiac computed tomography to 83 ms per heart-phase. In this study, the clinical performance of this new method is evaluated. Materials and Methods: In fifty patients (33 male, 17 female; age 50±13 years) with suspected coronary heart disease, CT angiography (slice thickness 0,75 mm, contrast-agent 60-80 ml iomeprol) was performed with a Somatom Definition scanner. Based on the coronary 15-segment-model of the AHA, scores for image quality and lumen reduction were established to enable the observer, to give recommendations for further therapy. Results: Out of 750 possible AHA-segments, 655 were depicted (87,3%). 591 segments (90,2%) were assessed without any limitation of quality, 49 (7,5%) segments showed moderate, and 15 (2,3%) segments severe limitation in image quality. 508 (77,6%) segments were without pathological findings, 92 (14,0%) segments had minimal atherosclerotic lesions, 42 (6,4%) segments suffered from stenoses with lumen reduction less than 70%, and 13 (2,0%) showed significant stenoses of more than 70%. In 31 patients (62%), coronary heart disease was ruled out by CT angiography without any need for further non-invasive or invasive diagnostics. 8 patients (16%) underwent stress-testing for ischemia. In 11 (22%) patients coronary angiography was recommended, and DSCT findings were confirmed in 10 cases. Only one LCx stenosis was overestimated in DSCT. Conclusion: Contrast-enhanced DSCT is a powerful tool in diagnosis of coronary heart disease. 98% of coronary segments could be assessed in diagnostic quality, and at least 90% of haemodynamically significant coronary stenoses were detected. (orig.)

  12. Does analgesia affect the diagnostic process in acute abdomen? a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Khashayar P.

    2008-03-01

    Full Text Available Background: About one-forth of the patients admitted to the emergency department complain of acute abdominal pain. According to surgical records, most surgeons believe that pain relief for these patients may interfere with the clinical examinations and the final diagnoses. As a result, analgesics are withheld in patients with acute abdominal pain until the determination of a definite diagnosis and suitable management plan. The purpose of this study was to evaluate the effect of analgesics on the evaluation course and treatment in acute abdomen.Methods: Two hundred patients at a surgical emergency department with acute abdominal pain were enrolled in this prospective study and randomly divided into two groups at the time of admission. The case group consisted of 98 patients who received intravenous analgesia immediately after admission. The other 102 patients in the control group did not receive analgesia until a definite diagnosis was made. Diagnostic and therapeutic procedures were similar between the two groups. The primary and final diagnoses, and the time intervals between the admission and definite diagnosis, and that between admission and surgery were gathered and analyzed.Results: The mean time to definitive diagnosis was 1.7 and 2.04 hours in the case and control groups, respectively. There was no statistically significant relationship between analgesic use and gender, age, time to definite diagnosis, or accuracy of the diagnosis. In fact, the time required to achieve a definite diagnosis and the time between admission and surgery were less in the group that had received analgesics. Conclusions: In spite of the fact that analgesics remove the very symptoms that brings patients to the emergency room, appropriate use of analgesics does not reduce diagnostic efficiency for patients with acute abdominal pain.

  13. Kinetics of circulating antibody response to Trichomonas vaginalis: clinical and diagnostic implications.

    Science.gov (United States)

    Ton Nu, Phuong Anh; Rappelli, Paola; Dessì, Daniele; Nguyen, Vu Quoc Huy; Fiori, Pier Luigi

    2015-12-01

    Persistence of antibodies against pathogens after antimicrobial treatment is a marker of therapy failure or evolution to a chronic infection. The kinetics of antibody production decrease following antigen elimination is highly variable, and predicting the duration of soluble immunity in infectious diseases is often impossible. This hampers the development and use of immunoassays for diagnostic and seroepidemiological purposes. In the case of Trichomonas vaginalis infection, the kinetics of antibody levels decrease following therapy has never been studied. We thus investigated the clearance of circulating anti-T. vaginalis IgGs after pharmacological treatment in patients affected by trichomoniasis. 18 female patients affected by acute trichomoniasis were enrolled in this study. After metronidazole therapy administration, subjects were followed up monthly up to 5 months, and serum levels of anti-T. vaginalis IgGs were measured by ELISA. We showed that a successful therapy is characterised by a relatively fast decline of specific antibodies, until turning into negative by ELISA in 1-3 months. In a few patients we observed that the persistence of anti-T. vaginalis antibodies was associated with an evolution to chronic infection, which may be due to treatment failure or to reinfection by untreated sexual partners. Our results describe the direct correlation between the decline of a specific humoral anti-T. vaginalis response and an effective antimicrobial therapy. These findings may facilitate the follow-up approach to circumvent limitations in developing new diagnostic tools and techniques routinely used in microbiology laboratories to assess the presence of T. vaginalis in clinical samples. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Diagnostic clinical and laboratory findings in response to predetermining bacterial pathogen: data from the Meningitis Registry.

    Directory of Open Access Journals (Sweden)

    Maria Karanika

    Full Text Available BACKGROUND: Childhood meningitis continues to be an important cause of mortality in many countries. The search for rapid diagnosis of acute bacterial meningitis has lead to the further exploration of prognostic factors. This study was scheduled in an attempt to analyze various clinical symptoms as well as rapid laboratory results and provide an algorithm for the prediction of specific bacterial aetiology of childhood bacterial meningitis. METHODOLOGY AND PRINCIPAL FINDINGS: During the 32 year period, 2477 cases of probable bacterial meningitis (BM were collected from the Meningitis Registry (MR. Analysis was performed on a total of 1331 confirmed bacterial meningitis cases of patients aged 1 month to 14 years. Data was analysed using EPI INFO (version 3.4.3-CDC-Atlanta and SPSS (version 15.0-Chicago software. Statistically significant (p or = 15000/microL (OR 2.19 with a PPV of 77.8% (95%CI 40.0-97.2. For the diagnosis of Haemophilus influenzae, the most significant group of diagnostic criteria included, absence of haemorrhagic rash (OR 13.61, age > or = 1 year (OR 2.04, absence of headache (OR 3.01, CSF Glu < 40 mg/dL (OR 3.62 and peripheral WBC < 15,000/microL (OR 1.74 with a PPV of 58.5% (95%CI 42.1-73.7. CONCLUSIONS: The use of clinical and laboratory predictors for the assessment of the causative bacterial pathogen rather than just for predicting outcome of mortality seems to be a useful tool in the clinical management and specific treatment of BM. These findings should be further explored and studied.

  15. Development of a clinical diagnostic matrix for characterizing inherited epidermolysis bullosa.

    Science.gov (United States)

    Yenamandra, V K; Moss, C; Sreenivas, V; Khan, M; Sivasubbu, S; Sharma, V K; Sethuraman, G

    2017-06-01

    Accurately diagnosing the subtype of epidermolysis bullosa (EB) is critical for management and genetic counselling. Modern laboratory techniques are largely inaccessible in developing countries, where the diagnosis remains clinical and often inaccurate. To develop a simple clinical diagnostic tool to aid in the diagnosis and subtyping of EB. We developed a matrix indicating presence or absence of a set of distinctive clinical features (as rows) for the nine most prevalent EB subtypes (as columns). To test an individual patient, presence or absence of these features was compared with the findings expected in each of the nine subtypes to see which corresponded best. If two or more diagnoses scored equally, the diagnosis with the greatest number of specific features was selected. The matrix was tested using findings from 74 genetically characterized patients with EB aged > 6 months by an investigator blinded to molecular diagnosis. For concordance, matrix diagnoses were compared with molecular diagnoses. Overall, concordance between the matrix and molecular diagnoses for the four major types of EB was 91·9%, with a kappa coefficient of 0·88 [95% confidence interval (CI) 0·81-0·95; P < 0·001]. The matrix achieved a 75·7% agreement in classifying EB into its nine subtypes, with a kappa coefficient of 0·73 (95% CI 0·69-0·77; P < 0·001). The matrix appears to be simple, valid and useful in predicting the type and subtype of EB. An electronic version will facilitate further testing. © 2016 British Association of Dermatologists.

  16. Development and clinical application of transient elastography(FibroScan

    Directory of Open Access Journals (Sweden)

    Guo-feng CHEN

    2011-11-01

    Full Text Available Chronic liver fibrosis,an important step in the development of liver diseases,is an anaplerotic reaction of an organism to chronic liver damage caused by various kinds of pathogens.It is a common pathologic change in chronic liver diseases and the intermediate link in the development of liver cirrhosis.Liver fibrosis can be reversed in the early stage,as well as in the later stage.Cases of liver cirrhosis that are confirmed during the earlier stage can be treated and prognosticated more efficiently.Currently,liver biopsy is still the gold standard for diagnosing liver fibrosis.However,its invasiveness causes patients to refuse the examination.Noninvasive diagnostic technology for liver fibrosis has made considerable development in recent years.One of these technologies is transient elastography(FibroScan of liver stiffness using elastic shear wave,which has good accuracy and specificity for the determination of liver fibrosis.It is noninvasive,fast,repeatable,and it can evaluate liver fibrosis objectively and quantitatively.It will have a broad range of clinical applications in the future.

  17. [The quality management in clinical diagnostic laboratory in conditions of the Federal Center of traumatology, orthopedics and endoprosthesis replacement of Minzdrav of Russia (Cheboksary)].

    Science.gov (United States)

    Nikolaev, N S; Nazarova, V V; Dobrovol'skaia, N Iu; Orlova, A V; Pchelova, N N

    2014-10-01

    The article presents experience of clinical diagnostic laboratory of the Federal Center of traumatology, orthopedics and endoprosthesis replacement of Minzdrav of Russia (Cheboksary) in the area of quality management of medical laboratory services on the basis of evaluation of efficacy and effectiveness of processes. The factors effecting quality of functioning of clinical diagnostic laboratory are indicated. The criteria and indicators of efficacy of work of employees of clinical diagnostic laboratory are presented.

  18. Principles for new optical techniques in medical diagnostics for mHealth applications

    Science.gov (United States)

    Balsam, Joshua Michael

    Medical diagnostics is a critical element of effective medical treatment. However, many modern and emerging diagnostic technologies are not affordable or compatible with the needs and conditions found in low-income and middle-income countries and regions. Resource-poor areas require low-cost, robust, easy-to-use, and portable diagnostics devices compatible with telemedicine (i.e. mHealth) that can be adapted to meet diverse medical needs. Many suitable devices will need to be based on optical technologies, which are used for many types of biological analyses. This dissertation describes the fabrication and detection principles for several low-cost optical technologies for mHealth applications including: (1) a webcam based multi-wavelength fluorescence plate reader, (2) a lens-free optical detector used for the detection of Botulinum A neurotoxin activity, (3) a low cost micro-array reader that allows the performance of typical fluorescence based assays demonstrated for the detection of the toxin staphylococcal enterotoxin (SEB), and (4) a wide-field flow cytometer for high throughput detection of fluorescently labeled rare cells. This dissertation discusses how these technologies can be harnessed using readily available consumer electronics components such as webcams, cell phones, CCD cameras, LEDs, and laser diodes. There are challenges in developing devices with sufficient sensitivity and specificity, and approaches are presented to overcoming these challenges to create optical detectors that can serve as low cost medical diagnostics in resource-poor settings for mHealth.

  19. Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application.

    Science.gov (United States)

    Gong, Max M; Sinton, David

    2017-06-28

    Infectious diseases are a major global health issue. Diagnosis is a critical first step in effectively managing their spread. Paper-based microfluidic diagnostics first emerged in 2007 as a low-cost alternative to conventional laboratory testing, with the goal of improving accessibility to medical diagnostics in developing countries. In this review, we examine the advances in paper-based microfluidic diagnostics for medical diagnosis in the context of global health from 2007 to 2016. The theory of fluid transport in paper is first presented. The next section examines the strategies that have been employed to control fluid and analyte transport in paper-based assays. Tasks such as mixing, timing, and sequential fluid delivery have been achieved in paper and have enabled analytical capabilities comparable to those of conventional laboratory methods. The following section examines paper-based sample processing and analysis. The most impactful advancement here has been the translation of nucleic acid analysis to a paper-based format. Sma