WorldWideScience

Sample records for cleared 510k devices

  1. 75 FR 4402 - Strengthening the Center for Devices and Radiological Health's 510(k) Review Process; Public...

    Science.gov (United States)

    2010-01-27

    ... beginning at 7 a.m. If you need special accommodations due to a disability, please contact James Swink at...) under the 510(k) Paradigm, bundling of devices in 510(k) submissions, and reliance on 510(k) submitters...

  2. 76 FR 45825 - Center for Devices and Radiological Health 510(k) Clearance Process; Institute of Medicine Report...

    Science.gov (United States)

    2011-08-01

    ... Drug Administration (FDA) is requesting comments on the Institute of Medicine (IOM) report entitled... assessment of the 510(k) process was an independent study by the IOM. At the request of FDA, IOM has..., 2011, IOM released the report ``Medical Devices and the Public's Health, The FDA 510(k) Clearance...

  3. 78 FR 26786 - 510(k) Device Modifications: Deciding When To Submit a 510(k) for a Change to an Existing Device...

    Science.gov (United States)

    2013-05-08

    ....m. If you need special accommodations due to a disability, please contact Joyce Raines, 301-796-5709..., which ones? 5. Could critical specifications be implemented as an optional paradigm? This approach could... current 510(k) modifications decision-making paradigm. Please discuss the practical implications of this...

  4. 75 FR 47307 - Center for Devices and Radiological Health 510(k) Working Group Preliminary Report and...

    Science.gov (United States)

    2010-08-05

    ..., and Task Force on the Utilization of Science in Regulatory Decision Making Preliminary Report and...: The 510(k) Working Group and the Task Force on the Utilization of Science in Regulatory Decision Making. Volume I is entitled ``510(k) Working Group Preliminary Report and Recommendations.'' Volume II...

  5. The "déjà vu effect:" evaluation of United States medical device legislation, regulation, and the Food and Drug Administration's contentious 510(k) program.

    Science.gov (United States)

    Bauman, Jordan

    2012-01-01

    With the Medical Device Amendments of 1976, Congress granted FDA authority to regulate medical devices by implementing a risk-based regulatory framework. Several years prior to this legislation, the Cooper Committee reviewed the medical device regulatory landscape and uncovered weaknesses that could be detrimental to public health. However, only after several high-profile incidents involving unsafe medical devices did Congress respond with strong legislation. Since 1976, additional medical device legislative revisions have been enacted to address deficiencies highlighted by various groups representing Congress, FDA, and industry. A repetitive conclusion from these groups has been that the 510(k) program is incapable of serving as a premarket evaluation of safety and effectiveness under the existing statutory framework. However, these legislative revisions did not change the statutory framework despite these repeated findings. In 2009, CDRH convened separate groups to again review the 510(k) program. While more comprehensive than previous initiatives, the observed deficiencies and the proposed recommendations are remarkably similar to those identified by their predecessors. This cyclical review of the medical device regulatory landscape whereby the same observations and recommendations are repeated yet the output of such review does not yield major legislative revision of the existing statutory framework can be described as the "déjà vu effect." This will continue unless Congress enacts legislation that implements a new statutory framework with a different standard other than substantial equivalence. In the past, Congress has implemented major legislation only after a public health crisis. Hopefully this will not be the driving force in the future.

  6. Photobiomodulation therapy for androgenetic alopecia: A clinician's guide to home-use devices cleared by the Federal Drug Administration.

    Science.gov (United States)

    Dodd, Erin M; Winter, Margo A; Hordinsky, Maria K; Sadick, Neil S; Farah, Ronda S

    2018-06-01

    The market for home-use photobiomodulation devices to treat androgenetic alopecia has rapidly expanded, and the Food and Drug Administration (FDA) has recently cleared many devices for this purpose. Patients increasingly seek the advice of dermatologists regarding the safety and efficacy of these hair loss treatments. The purpose of this guide was threefold: (1) to identify all home-use photobiomodulation therapy devices with FDA-clearance for treatment of androgenetic alopecia; (2) to review device design, features and existing clinical evidence; and (3) to discuss practical considerations of photobiomodulation therapy, including patient suitability, treatment goals, safety, and device selection. A search of the FDA 510(k) Premarket Notification database was conducted using product code "OAP" to identify all home-use devices that are FDA-cleared to treat androgenetic alopecia. Thirteen commercially available devices were identified and compared. Devices varied in shape, wavelength, light sources, technical features, price, and level of clinical evidence. To date, there are no head-to-head studies comparing the efficacy of these devices. Photobiomodulation therapy devices have an excellent safety profile and mounting evidence supporting their efficacy. However, long-term, high quality studies comparing these devices in diverse populations are lacking. As these devices become increasingly popular, dermatologists should be familiar with this treatment modality to add to their therapeutic armamentarium. AGA, androgenetic alopecia; FDA, Food and Drug Administration; IEC, International Electrotechnical Commission; LED, light-emitting diode; PBMT, photobiomodulation therapy.

  7. Medical devices; exemption from premarket notification; class II devices; wheelchair elevator. Final order.

    Science.gov (United States)

    2013-03-04

    The Food and Drug Administration (FDA) is publishing an order granting a petition requesting exemption from premarket notification requirements for wheelchair elevator devices commonly known as inclined platform lifts and vertical platform lifts. These devices are used to provide a means for a person with a mobility impairment caused by injury or other disease to move from one level to another, usually in a wheelchair. This order exempts wheelchair elevators, class II devices, from premarket notification and establishes conditions for exemption for this device that will provide a reasonable assurance of the safety and effectiveness of the device without submission of a premarket notification (510(k)). This exemption from 510(k), subject to these conditions, is immediately in effect for wheelchair elevators. All other devices classified under FDA's wheelchair elevator regulations, including attendant-operated stair climbing devices for wheelchairs and portable platform lifts, continue to require submission of 510(k)s. FDA is publishing this order in accordance with the section of the Food, Drug, and Cosmetic Act (the FD&C Act) permitting the exemption of a device from the requirement to submit a 510(k).

  8. 21 CFR 864.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 864.9 Section 864.9 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY...

  9. 77 FR 44256 - Draft Guidance for Industry and Food and Drug Administration Staff; Safety Considerations for 510...

    Science.gov (United States)

    2012-07-27

    ...] Draft Guidance for Industry and Food and Drug Administration Staff; Safety Considerations for 510(k... serious and sometimes fatal consequences to patients. This guidance provides recommendations to 510(k... unintended connections between enteral and nonenteral devices. This draft guidance is not final nor is it in...

  10. 21 CFR 886.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 886.9 Section 886.9 Food and Drugs FOOD AND DRUG... Provisions § 886.9 Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act...

  11. 21 CFR 874.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 874.9 Section 874.9 Food and Drugs FOOD AND DRUG... Cosmetic Act (the act). The exemption from the requirement of premarket notification (section 510(k) of the...

  12. 21 CFR 872.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 872.9 Section 872.9 Food and Drugs FOOD AND DRUG... Provisions § 872.9 Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act...

  13. 21 CFR 870.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 870.9 Section 870.9 Food and Drugs FOOD AND DRUG... Cosmetic Act (the act). The exemption from the requirement of premarket notification (section 510(k) of the...

  14. 21 CFR 868.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 868.9 Section 868.9 Food and Drugs FOOD AND DRUG... Cosmetic Act (the act). The exemption from the requirement of premarket notification (section 510(k) of the...

  15. 21 CFR 888.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 888.9 Section 888.9 Food and Drugs FOOD AND DRUG... Provisions § 888.9 Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act...

  16. 21 CFR 892.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 892.9 Section 892.9 Food and Drugs FOOD AND DRUG... Provisions § 892.9 Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act...

  17. 21 CFR 882.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 882.9 Section 882.9 Food and Drugs FOOD AND DRUG... Provisions § 882.9 Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act...

  18. Mechanical performance of cervical intervertebral body fusion devices: A systematic analysis of data submitted to the Food and Drug Administration.

    Science.gov (United States)

    Peck, Jonathan H; Sing, David C; Nagaraja, Srinidhi; Peck, Deepa G; Lotz, Jeffrey C; Dmitriev, Anton E

    2017-03-21

    Cervical intervertebral body fusion devices (IBFDs) are utilized to provide stability while fusion occurs in patients with cervical pathology. For a manufacturer to market a new cervical IBFD in the United States, substantial equivalence to a cervical IBFD previously cleared by FDA must be established through the 510(k) regulatory pathway. Mechanical performance data are typically provided as part of the 510(k) process for IBFDs. We reviewed all Traditional 510(k) submissions for cervical IBFDs deemed substantially equivalent and cleared for marketing from 2007 through 2014. To reduce sources of variability in test methods and results, analysis was restricted to cervical IBFD designs without integrated fixation, coatings, or expandable features. Mechanical testing reports were analyzed and results were aggregated for seven commonly performed tests (static and dynamic axial compression, compression-shear, and torsion testing per ASTM F2077, and subsidence testing per ASTM F2267), and percentile distributions of performance measurements were calculated. Eighty-three (83) submissions met the criteria for inclusion in this analysis. The median device yield strength was 10,117N for static axial compression, 3680N for static compression-shear, and 8.6Nm for static torsion. Median runout load was 2600N for dynamic axial compression, 1400N for dynamic compression-shear, and ±1.5Nm for dynamic torsion. In subsidence testing, median block stiffness (Kp) was 424N/mm. The mechanical performance data presented here will aid in the development of future cervical IBFDs by providing a means for comparison for design verification purposes. Published by Elsevier Ltd.

  19. 21 CFR 878.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 878.9 Section 878.9 Food and Drugs FOOD AND DRUG..., and Cosmetic Act (the act). The exemption from the requirement of premarket notification (section 510...

  20. 21 CFR 884.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 884.9 Section 884.9 Food and Drugs FOOD AND DRUG..., and Cosmetic Act (the act). The exemption from the requirement of premarket notification (section 510...

  1. 21 CFR 876.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 876.9 Section 876.9 Food and Drugs FOOD AND DRUG..., and Cosmetic Act (the act). The exemption from the requirement of premarket notification (section 510...

  2. 78 FR 14097 - Pulse Oximeters-Premarket Notification Submissions [510(k)s]; Guidance for Industry and Food and...

    Science.gov (United States)

    2013-03-04

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2007-D-0205 (Formerly 2007D-0252)] Pulse Oximeters--Premarket Notification Submissions [510(k)s]; Guidance for Industry and Food and Drug Administration Staff; Availability AGENCY: Food and Drug Administration, HHS. ACTION...

  3. #DDOD: Establishment Registration & Device Listing

    Data.gov (United States)

    U.S. Department of Health & Human Services — SUMMARY DDOD use case to request means on consolidating multiple data sources (MDR, PMA, 510(k), R&L) in order to build a list of all marketed medical devices....

  4. Method of manufacturing semiconductor devices

    International Nuclear Information System (INIS)

    Sun, Y.S.E.

    1980-01-01

    A method of improving the electrical characteristics of semiconductor devices such as SCR's, rectifiers and triacs during their manufacture is described. The system consists of electron irradiation at an energy in excess of 250 KeV and most preferably between 1.5 and 12 MeV, producing an irradiation dose of between 5.10 12 and 5.10 15 electrons per sq. cm., and at a temperature in excess of 100 0 C preferably between 150 and 375 0 C. (U.K.)

  5. 78 FR 100 - Guidance for Industry and Food and Drug Administration Staff; Refuse To Accept Policy for 510(k)s...

    Science.gov (United States)

    2013-01-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-D-0523] Guidance for Industry and Food and Drug Administration Staff; Refuse To Accept Policy for 510(k)s; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug...

  6. 76 FR 50230 - Center for Devices and Radiological Health 510(k) Clearance Process; Recommendations Proposed in...

    Science.gov (United States)

    2011-08-12

    ... develop and implement a program of continuous quality improvement to track regulatory decisions on medical devices, identify potential process improvements in the medical device regulatory framework, and address... software used in devices, software used as devices, and software used as a tool in producing devices. 8...

  7. Class 1 devices case studies in medical devices design

    CERN Document Server

    Ogrodnik, Peter J

    2014-01-01

    The Case Studies in Medical Devices Design series consists of practical, applied case studies relating to medical device design in industry. These titles complement Ogrodnik's Medical Device Design and will assist engineers with applying the theory in practice. The case studies presented directly relate to Class I, Class IIa, Class IIb and Class III medical devices. Designers and companies who wish to extend their knowledge in a specific discipline related to their respective class of operation will find any or all of these titles a great addition to their library. Class 1 Devices is a companion text to Medical Devices Design: Innovation from Concept to Market. The intention of this book, and its sister books in the series, is to support the concepts presented in Medical Devices Design through case studies. In the context of this book the case studies consider Class I (EU) and 510(k) exempt (FDA) . This book covers classifications, the conceptual and embodiment phase, plus design from idea to PDS. These title...

  8. 21 CFR 880.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 880.9 Section 880.9 Food and Drugs FOOD AND DRUG... Food, Drug, and Cosmetic Act (the act). The exemption from the requirement of premarket notification...

  9. 21 CFR 862.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 862.9 Section 862.9 Food and Drugs FOOD AND DRUG... Federal Food, Drug, and Cosmetic Act (the act). The exemption from the requirement of premarket...

  10. 40 CFR 1065.510 - Engine mapping.

    Science.gov (United States)

    2010-07-01

    ....510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS... the atmospheric pressure near the engine's air inlet is not within ± 5 kPa of the atmospheric pressure recorded at the time of the last engine map. (3) If the engine or emission-control system has undergone...

  11. 30 CFR 250.510 - Diesel engine air intakes.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Diesel engine air intakes. 250.510 Section 250... engine air intakes. Diesel engine air intakes must be equipped with a device to shut down the diesel engine in the event of runaway. Diesel engines that are continuously attended must be equipped with...

  12. Modification of NaK (Na and K) dissolution device at the L.E.C.I

    International Nuclear Information System (INIS)

    Mansard, Bernard; Ducas, Serge; Riviere, Michel

    1969-12-01

    As three NaK dissolution devices had been operated since 1965 and as irradiation assemblies with a greater capacity (2 to 3 times) are now to be used, the modification of these dissolution devices is addressed. This requires a better control of the dissolution reaction (the NaK + alcohol reaction is highly exothermic and results in an effervescence which requires a greater volume). The objectives are therefore to delay the dissolution, to trigger it, to stop it, to control it at will, and to release heat. The new device is then described with its vessel, its cap, its ball valve, and its two tight sleeves. The operation principle is described, as well as the NaK draining process, and the NaK dissolution. Safety, time saving and raw matter saving issues are finally outlined

  13. Test plan for K Basin Sludge Canister and Floor Sampling Device

    International Nuclear Information System (INIS)

    Meling, T.A.

    1995-01-01

    This document provides the test plan and procedure forms for conducting the functional and operational acceptance testing of the K Basin Sludge Canister and Floor Sampling Device(s). These samplers samples sludge off the floor of the 100K Basins and out of 100K fuel storage canisters

  14. No clear Y2K roadmap can be costly; may create serious liability.

    Science.gov (United States)

    1998-12-01

    Hospitals without Year 2000 plans in place could be setting themselves up for costly equipment failure. Learn what the experts say about prioritizing to ensure patient care isn't disrupted, and find out about testing medical devices and equipment for Y2K compliance, and what to consider when setting up a Y2K analysis program in your hospital, including how to ensure vendors tell you the truth about whether their products are Y2K compliant.

  15. Calorimetric study of alternating copolymer of bicyclo[2,2,1]-hepta-2,5-diene and carbon monoxide in the range from T->0 to 510K

    International Nuclear Information System (INIS)

    Smirnova, N.N.; Nikishchenkova, L.V.; Bykova, T.A.; Kulagina, T.G.; Belov, G.P.; Novikova, E.V.

    2006-01-01

    By adiabatic vacuum and dynamic calorimetry, the temperature dependence of heat capacity for alternating copolymer of bicyclo[2,2,1]-hepta-2,5-diene and carbon monoxide has been determined over the 6-510K range with an uncertainty of 0.2-0.5% between 6 and 350K and 0.5-1.5% from 330 to 510K. In the above temperature ranges, the physical transformations of the copolymer have been detected and their thermodynamic characteristics have been estimated. In a calorimeter with a static bomb and an isothermal shield, the energy of combustion of the copolymer has been measured at 298.15K. Based on the experimental data, the thermodynamic functions of the copolymer, namely, the heat capacity C p - bar (T), enthalpy H o (T)-H o (0), entropy S o (T)-S o (0) and Gibbs function G o (T)-H o (0) have been determined for the range from T->0 to 400K. The enthalpy of combustion Δ c H o and the thermodynamic parameters Δ f H o , Δ f S o , Δ f G o and lnK f - bar of reaction of formation of the copolymer from simple substances at T=298.15K and p=0.1MPa have been calculated. The data cited in the present work and literature data were used to calculate the thermodynamic characteristics of the alternating copolymerization in bulk of bicyclo[2,2,1]-hepta-2,5-diene and CO in the 0-340K range at standard pressure as well as to compare them with the thermodynamic characteristics of the synthesis of isomeric polyketone

  16. Calorimetric study of alternating copolymer of bicyclo[2,2,1]-hepta-2,5-diene and carbon monoxide in the range from T->0 to 510K

    Energy Technology Data Exchange (ETDEWEB)

    Smirnova, N.N. [Research Institute of Chemistry, Nizhny Novgorod University, Gagarin Prospekt 23/5, 603950 Nizhny Novgorod (Russian Federation)]. E-mail: smirnova@ichem.unn.runnet.ru; Nikishchenkova, L.V. [Research Institute of Chemistry, Nizhny Novgorod University, Gagarin Prospekt 23/5, 603950 Nizhny Novgorod (Russian Federation); Bykova, T.A. [Research Institute of Chemistry, Nizhny Novgorod University, Gagarin Prospekt 23/5, 603950 Nizhny Novgorod (Russian Federation); Kulagina, T.G. [Research Institute of Chemistry, Nizhny Novgorod University, Gagarin Prospekt 23/5, 603950 Nizhny Novgorod (Russian Federation); Belov, G.P. [Institute of Problems of Chemical Physics of Russian Academy Sciences, 142432 Chernogolovka, Moscow Region (Russian Federation); Novikova, E.V. [Institute of Problems of Chemical Physics of Russian Academy Sciences, 142432 Chernogolovka, Moscow Region (Russian Federation)

    2006-12-01

    By adiabatic vacuum and dynamic calorimetry, the temperature dependence of heat capacity for alternating copolymer of bicyclo[2,2,1]-hepta-2,5-diene and carbon monoxide has been determined over the 6-510K range with an uncertainty of 0.2-0.5% between 6 and 350K and 0.5-1.5% from 330 to 510K. In the above temperature ranges, the physical transformations of the copolymer have been detected and their thermodynamic characteristics have been estimated. In a calorimeter with a static bomb and an isothermal shield, the energy of combustion of the copolymer has been measured at 298.15K. Based on the experimental data, the thermodynamic functions of the copolymer, namely, the heat capacity C{sub p}{sup -}bar (T), enthalpy H{sup o}(T)-H{sup o}(0), entropy S{sup o}(T)-S{sup o}(0) and Gibbs function G{sup o}(T)-H{sup o}(0) have been determined for the range from T->0 to 400K. The enthalpy of combustion {delta}{sub c}H{sup o} and the thermodynamic parameters {delta}{sub f}H{sup o}, {delta}{sub f}S{sup o}, {delta}{sub f}G{sup o} and lnK{sub f}{sup -}bar of reaction of formation of the copolymer from simple substances at T=298.15K and p=0.1MPa have been calculated. The data cited in the present work and literature data were used to calculate the thermodynamic characteristics of the alternating copolymerization in bulk of bicyclo[2,2,1]-hepta-2,5-diene and CO in the 0-340K range at standard pressure as well as to compare them with the thermodynamic characteristics of the synthesis of isomeric polyketone.

  17. 76 FR 14028 - Center for Devices and Radiological Health 510(k) Implementation: Online Repository of Medical...

    Science.gov (United States)

    2011-03-15

    ... could facilitate patient access to information on what types of devices are available for their medical... input from the public on what they would want and need in labeling and how they would want to access it. CDRH is also interested in learning more about how patients, consumers, and caregivers acquire and use...

  18. 28 CFR 54.510 - Recruitment.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Recruitment. 54.510 Section 54.510... in Employment in Education Programs or Activities Prohibited § 54.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment...

  19. 22 CFR 229.510 - Recruitment.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Recruitment. 229.510 Section 229.510 Foreign... in Education Programs or Activities Prohibited § 229.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring...

  20. 22 CFR 146.510 - Recruitment.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Recruitment. 146.510 Section 146.510 Foreign... Education Programs or Activities Prohibited § 146.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees...

  1. 14 CFR 1253.510 - Recruitment.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Recruitment. 1253.510 Section 1253.510... in Employment in Education Programs or Activities Prohibited § 1253.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment...

  2. 43 CFR 41.510 - Recruitment.

    Science.gov (United States)

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Recruitment. 41.510 Section 41.510 Public... in Employment in Education Programs or Activities Prohibited § 41.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment...

  3. 49 CFR 25.510 - Recruitment.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Recruitment. 25.510 Section 25.510 Transportation... Education Programs or Activities Prohibited § 25.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees...

  4. 40 CFR 5.510 - Recruitment.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Recruitment. 5.510 Section 5.510... in Employment in Education Programs or Activities Prohibited § 5.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment...

  5. 6 CFR 17.510 - Recruitment.

    Science.gov (United States)

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false Recruitment. 17.510 Section 17.510 Domestic... in Employment in Education Programs or Activities Prohibited § 17.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment...

  6. 10 CFR 1042.510 - Recruitment.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Recruitment. 1042.510 Section 1042.510 Energy DEPARTMENT... Education Programs or Activities Prohibited § 1042.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees...

  7. Direct Determination of the Rate Coefficient for the Reaction of OH Radicals with Monoethanol Amine (MEA) from 296 to 510 K.

    Science.gov (United States)

    Onel, L; Blitz, M A; Seakins, P W

    2012-04-05

    Monoethanol amine (H2NCH2CH2OH, MEA) has been proposed for large-scale use in carbon capture and storage. We present the first absolute, temperature-dependent determination of the rate coefficient for the reaction of OH with MEA using laser flash photolysis for OH generation, monitoring OH removal by laser-induced fluorescence. The room-temperature rate coefficient is determined to be (7.61 ± 0.76) × 10(-11) cm(3) molecule(-1) s(-1), and the rate coefficient decreases by about 40% by 510 K. The temperature dependence of the rate coefficient is given by k1= (7.73 ± 0.24) × 10(-11)(T/295)(-(0.79±0.11)) cm(3) molecule(-1) s(-1). The high rate coefficient shows that gas-phase processing in the atmosphere will be competitive with uptake onto aerosols.

  8. 31 CFR 28.510 - Recruitment.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 1 2010-07-01 2010-07-01 false Recruitment. 28.510 Section 28.510... Basis of Sex in Employment in Education Programs or Activities Prohibited § 28.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment...

  9. 29 CFR 36.510 - Recruitment.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Recruitment. 36.510 Section 36.510 Labor Office of the... Activities Prohibited § 36.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees. Where a recipient has...

  10. 10 CFR 5.510 - Recruitment.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Recruitment. 5.510 Section 5.510 Energy NUCLEAR REGULATORY... Prohibited § 5.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees. Where a recipient has been found...

  11. Medical Device Recalls in Radiation Oncology: Analysis of US Food and Drug Administration Data, 2002-2015

    International Nuclear Information System (INIS)

    Connor, Michael J.; Tringale, Kathryn; Moiseenko, Vitali; Marshall, Deborah C.; Moore, Kevin; Cervino, Laura; Atwood, Todd; Brown, Derek; Mundt, Arno J.; Pawlicki, Todd; Recht, Abram; Hattangadi-Gluth, Jona A.

    2017-01-01

    Purpose: To analyze all recalls involving radiation oncology devices (RODs) from the US Food and Drug Administration (FDA)'s recall database, comparing these with non–radiation oncology device recalls to identify discipline-specific trends that may inform improvements in device safety. Methods and Materials: Recall data on RODs from 2002 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems). Outcomes included determined cause of recall, recall class (severity), quantity in commerce, time until recall termination (date FDA determines recall is complete), and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by Pearson χ"2 test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 502 ROD recalls and 9534 other class II device recalls during 2002 to 2015. Most recalls were for external beam devices (66.7%) and planning systems (22.9%), and recall events peaked in 2011. Radiation oncology devices differed significantly from other devices in all recall outcomes (P≤.04). Recall cause was commonly software related (49% vs 10% for other devices). Recall severity was more often moderate among RODs (97.6% vs 87.2%) instead of severe (0.2% vs 4.4%; P<.001). Time from 510(k) market approval to recall was shorter among RODs (P<.001) and progressively shortened over time. Radiation oncology devices had fewer recalled devices in commerce than other devices (P<.001). Conclusions: Compared with other class II devices, RODs experience recalls sooner after market approval and are trending sooner still. Most of these recalls were moderate in severity, and software issues are prevalent. Comprehensive analysis of recall data can identify areas for device improvement, such as better system design among RODs.

  12. Medical Device Recalls in Radiation Oncology: Analysis of US Food and Drug Administration Data, 2002-2015

    Energy Technology Data Exchange (ETDEWEB)

    Connor, Michael J. [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States); University of California Irvine School of Medicine, Irvine, California (United States); Tringale, Kathryn; Moiseenko, Vitali; Marshall, Deborah C.; Moore, Kevin; Cervino, Laura; Atwood, Todd; Brown, Derek; Mundt, Arno J.; Pawlicki, Todd [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States); Recht, Abram [Department of Radiation Oncology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts (United States); Hattangadi-Gluth, Jona A., E-mail: jhattangadi@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States)

    2017-06-01

    Purpose: To analyze all recalls involving radiation oncology devices (RODs) from the US Food and Drug Administration (FDA)'s recall database, comparing these with non–radiation oncology device recalls to identify discipline-specific trends that may inform improvements in device safety. Methods and Materials: Recall data on RODs from 2002 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems). Outcomes included determined cause of recall, recall class (severity), quantity in commerce, time until recall termination (date FDA determines recall is complete), and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 502 ROD recalls and 9534 other class II device recalls during 2002 to 2015. Most recalls were for external beam devices (66.7%) and planning systems (22.9%), and recall events peaked in 2011. Radiation oncology devices differed significantly from other devices in all recall outcomes (P≤.04). Recall cause was commonly software related (49% vs 10% for other devices). Recall severity was more often moderate among RODs (97.6% vs 87.2%) instead of severe (0.2% vs 4.4%; P<.001). Time from 510(k) market approval to recall was shorter among RODs (P<.001) and progressively shortened over time. Radiation oncology devices had fewer recalled devices in commerce than other devices (P<.001). Conclusions: Compared with other class II devices, RODs experience recalls sooner after market approval and are trending sooner still. Most of these recalls were moderate in severity, and software issues are prevalent. Comprehensive analysis of recall data can identify areas for device improvement, such as better system design among RODs.

  13. Measurements of ODAK-3K plasma device using plastic track detectors

    International Nuclear Information System (INIS)

    2010-01-01

    In this study, some testing experiments on the fusion researches with a new-constructed plasma focus (PF) device, namely ODAK-3K are reported. The device has a maximal energy input of 3 kJ and is used for both plasma and D D reaction explorations. Experiments with deuterium have shown that peak current of I p eak=39 kA flows between the electrodes at P=11.5 mbar for the operation voltage of V=14 kV. Average total neutron yield is measured around 3.3x10 5 neutrons per shot using CR-39 plastic detectors located opposite the anode inside the PF chamber

  14. 21 CFR 556.510 - Penicillin.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Penicillin. 556.510 Section 556.510 Food and Drugs... Residues of New Animal Drugs § 556.510 Penicillin. Tolerances are established for residues of penicillin and the salts of penicillin in food as follows: (a) 0.05 part per million (negligible residue) in the...

  15. FDA publishes checklist of Y2K high-risk devices.

    Science.gov (United States)

    1999-09-01

    Key points. The federal Food and Drug Administration (FDA) has developed a list of types of medical devices that have the potential for the most serious consequences for patients should they fail because of Y2K-related problems. This list of computer-controlled potentially high-risk devices can provide a guide to health care facilities regarding the types of devices that should receive priority in their assessment and remediation of medical devices. The list may change as the FDA receives comments on the types of devices included in the list.

  16. ASME N510 test results for Savannah River Site AACS filter compartments

    Energy Technology Data Exchange (ETDEWEB)

    Paul, J.D.; Punch, T.M. [Westinghouse Savannah River Company, Aiken, SC (United States)

    1995-02-01

    The K-Reactor at the Savannah River Site recently implemented design improvements for the Airborne Activity Confinement System (AACS) by procuring, installing, and testing new Air Cleaning Units, or filter compartments, to ASME AG-11, N509, and N510 requirements. Specifically, these new units provide documentable seismic resistance to a Design Basis Accident earthquake, provide 2 inch adsorber beds with 0.25 second residence time, and meet all AG-1, N509, and N510 requirements for testability and maintainability. This paper presents the results of the Site acceptance testing and discusses an issue associated with sample manifold qualification testing.

  17. 7 CFR 3052.510 - Audit findings.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Audit findings. 3052.510 Section 3052.510 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF THE CHIEF FINANCIAL OFFICER, DEPARTMENT OF AGRICULTURE AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Auditors § 3052.510 Audit...

  18. 47 CFR 73.510 - Antenna systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Antenna systems. 73.510 Section 73.510... Noncommercial Educational FM Broadcast Stations § 73.510 Antenna systems. (a) All noncommercial educational... § 73.316 concerning antenna systems contained in subpart B of this part. (b) Directional antenna. No...

  19. Technology evaluation: ABT-510, Abbott.

    NARCIS (Netherlands)

    Westphal, J.R.

    2004-01-01

    ABT-510 is a small peptide thrombospondin-1 mimetic angiogenesis inhibitor under development by Abbott Laboratories for the potential treatment of solid tumors. ABT-510 is undergoing phase II clinical trials.

  20. System of programming units for the K556RT4 and K556RT5 fixed programmed memory devices

    International Nuclear Information System (INIS)

    Bobkov, S.G.; Ermolin, Yu.V.; Kantserov, V.A.; Strigin, V.B.

    1983-01-01

    The programming system of constant programmable memory devices K556RT4 and K556RT5 that consist of two units (a programming device and an electrothermotraining unit) is described. The modules are made in the KAMAK standard. The programming device takes up 2 normal places, while the electrothermotraining block takes up 1 place. As information recording is done using a computer the time for programming is reduced and the possibility of errors is limited as compared with the manual method. The computer introduces the whole word to be recorded, not the separate parts, in the programming device. The transition to a new digit of a given word in the programming device is done automatically. This reduces the expense of computer time and accelerates the programming of microdiagrams

  1. 30 CFR 7.510 - New technology.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false New technology. 7.510 Section 7.510 Mineral... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Refuge Alternatives § 7.510 New technology. MSHA may approve a refuge alternative or a component that incorporates new knowledge or technology, if the...

  2. 10 CFR 4.510 - Self-evaluation.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Self-evaluation. 4.510 Section 4.510 Energy NUCLEAR... Programs or Activities Conducted by the U.S. Nuclear Regulatory Commission § 4.510 Self-evaluation. (a) The... representing handicapped persons, to participate in the self-evaluation process by submitting comments (both...

  3. Y2K embedded device issues in the oilpatch

    International Nuclear Information System (INIS)

    Lovatt, M.

    1998-01-01

    Information on the background of the year 2000 (Y2K) problem in process control systems in the oil and gas industry was presented. The problem, which stems from a date related malfunction, could result in a series of computer failures. Examples of the type of failures that process control devices at an electricity generating plant may experience as a result of the date change to the year 2000 ( rollover, leap year, special codes) were illustrated. The benefits of a shared process across the industry for testing and evaluating the potential for failure were stressed. As a general methodology for solving Y2K problems, an inventory should be taken to identify all items that may have date related aspects and to plan a strategy for remediation. The 'JumpStart' database has been developed as a tool for sharing information and to help businesses to move quickly through the assessment strategy phase of their Y2K projects. At present, this database contains over 41,000 separate items from over 5000 manufacturers. Since the beginning of collecting data for this database only 10 to 15 per cent of the devices showed any type of date-related failure, and only one to five per cent of these was a critical failure. Several examples of how devices fail are provided. 1 fig

  4. 15 CFR 8a.510 - Recruitment.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Recruitment. 8a.510 Section 8a.510... in Employment in Education Programs or Activities Prohibited § 8a.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment...

  5. 29 CFR 100.510 - Self-evaluation.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 2 2010-07-01 2010-07-01 false Self-evaluation. 100.510 Section 100.510 Labor Regulations... § 100.510 Self-evaluation. (a) The agency shall, by September 6, 1989, evaluate its current policies and... participate in the self-evaluation process by submitting comments (both oral and written). (c) The agency...

  6. 29 CFR 99.510 - Audit findings.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audit findings. 99.510 Section 99.510 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Auditors § 99.510 Audit... schedule of prior audit findings prepared by the auditee in accordance with § 99.315(b) materially...

  7. MO-F-16A-08: Have An Impact On More Patients From Your Ideas And Inventions

    Energy Technology Data Exchange (ETDEWEB)

    Morton, R [Quality and Regulatory Services, Inc., Lincoln, CA (United States)

    2014-06-15

    Purpose: To inform physicists how to obtain an FDA 510(k) clearance for the innovations they use in their facility and to make those ideas widely available to patients throughout the U.S. Methods: Give advice from 20 years experience of assisting in well over 100 successful 510(k) clearances. Results: Learn how to develop a 510(k) submission. Conclusion: Many physicists, physicians and radiation therapists have developed innovations that that are helpful to the patients in their institution. But, many of these innovations deserve to be made available to patients throughout the United States. The author, a Certified Radiological Physicist and former FDA employee, has consulted for over twenty years for inventors, start-ups and established medical device manufacturers to bring new devices to market in the U.S. and to assist them to established FDA compliant quality systems for manufacturing. In this presentation the audience will learn the important points for deciding to go forward with obtaining a Premarket Notification clearance [also known as a 510(k) clearance] to legally market a medical device in the United States. The FDA has published guidelines for submitting a 510(k) application. However, the methods used to efficiently develop the documentation for submission and to obtain clearance in the shortest possible time comes from the author's experience in assisting well over one hundred successful 510(k) clearances.Whether you want to start your own company or to market your idea to an established medical device manufacturer, the value of your innovation increases with a documented 510(k) clearance from FDA.

  8. MO-F-16A-08: Have An Impact On More Patients From Your Ideas And Inventions

    International Nuclear Information System (INIS)

    Morton, R

    2014-01-01

    Purpose: To inform physicists how to obtain an FDA 510(k) clearance for the innovations they use in their facility and to make those ideas widely available to patients throughout the U.S. Methods: Give advice from 20 years experience of assisting in well over 100 successful 510(k) clearances. Results: Learn how to develop a 510(k) submission. Conclusion: Many physicists, physicians and radiation therapists have developed innovations that that are helpful to the patients in their institution. But, many of these innovations deserve to be made available to patients throughout the United States. The author, a Certified Radiological Physicist and former FDA employee, has consulted for over twenty years for inventors, start-ups and established medical device manufacturers to bring new devices to market in the U.S. and to assist them to established FDA compliant quality systems for manufacturing. In this presentation the audience will learn the important points for deciding to go forward with obtaining a Premarket Notification clearance [also known as a 510(k) clearance] to legally market a medical device in the United States. The FDA has published guidelines for submitting a 510(k) application. However, the methods used to efficiently develop the documentation for submission and to obtain clearance in the shortest possible time comes from the author's experience in assisting well over one hundred successful 510(k) clearances.Whether you want to start your own company or to market your idea to an established medical device manufacturer, the value of your innovation increases with a documented 510(k) clearance from FDA

  9. 42 CFR 436.510 - Determination of dependency.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Determination of dependency. 436.510 Section 436.510 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Requirements for Medicaid Eligibility Dependency § 436.510 Determination of dependency. For families with...

  10. 44 CFR 19.510 - Recruitment.

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Recruitment. 19.510 Section... Programs or Activities Prohibited § 19.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees. Where a...

  11. 6 CFR 5.10 - Preservation of records.

    Science.gov (United States)

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false Preservation of records. 5.10 Section 5.10 Domestic Security DEPARTMENT OF HOMELAND SECURITY, OFFICE OF THE SECRETARY DISCLOSURE OF RECORDS AND INFORMATION Freedom of Information Act § 5.10 Preservation of records. Each component shall preserve all...

  12. 45 CFR 618.510 - Recruitment.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Recruitment. 618.510 Section 618.510 Public... Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees. Where a recipient has been found to be presently...

  13. 45 CFR 2555.510 - Recruitment.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Recruitment. 2555.510 Section 2555.510 Public... Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees. Where a recipient has been found to be presently...

  14. 32 CFR 196.510 - Recruitment.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false Recruitment. 196.510 Section 196.510 National... Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees. Where a recipient has been found to be presently...

  15. 24 CFR 3.510 - Recruitment.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Recruitment. 3.510 Section 3.510... Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees. Where a recipient has been found to be presently...

  16. 1 CFR 5.10 - Forms of publication.

    Science.gov (United States)

    2010-01-01

    ... 1 General Provisions 1 2010-01-01 2010-01-01 false Forms of publication. 5.10 Section 5.10 General Provisions ADMINISTRATIVE COMMITTEE OF THE FEDERAL REGISTER THE FEDERAL REGISTER GENERAL § 5.10 Forms of publication. Pursuant to section 1506 of title 44, United States Code, the Administrative Committee publishes...

  17. 12 CFR 510.4 - Service of process.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Service of process. 510.4 Section 510.4 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY MISCELLANEOUS ORGANIZATIONAL REGULATIONS § 510.4 Service of process. (a) Service of Process. Service of process may be made upon the Office...

  18. 50 CFR 510.9 - Uniform pay guidelines.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Uniform pay guidelines. 510.9 Section 510... ACT § 510.9 Uniform pay guidelines. (a) Compensation of members and staff of, and consultants to the... accordance with guidelines established by the Director of the Office of Management and Budget pursuant to...

  19. 22 CFR 510.1 - Service of process.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Service of process. 510.1 Section 510.1 Foreign Relations BROADCASTING BOARD OF GOVERNORS SERVICE OF PROCESS § 510.1 Service of process. (a) The General... accepting service of process for an employee in his/her official capacity, the General Counsel or his/her...

  20. Thermo-optical properties of 1H[3,4-b] quinoline films used in electroluminescent devices

    Science.gov (United States)

    Jaglarz, Janusz; Kępińska, Mirosława; Sanetra, Jerzy

    2014-06-01

    Electroluminescence cells with H[3,4-b] quinoline layers are promising devices for a blue light emitting EL diode. This work measured the optical reflectance as a function of temperature in copolymers PAQ layers deposited on Si crystalline substrate. Using the extended Cauchy dispersion model of the film refractive index we determined the thermo-optical coefficients for quinoline layers in the temperature range of 76-333 K from combined ellipsometric and spectrofotometric studies. The obtained values of thermo-optical coefficients of thin PAQ film, were negative and ranged in 5-10 × 10-4 [1/K].

  1. Teaching and Learning with Mobile Computing Devices: Case Study in K-12 Classrooms

    Science.gov (United States)

    Grant, Michael M.; Tamim, Suha; Brown, Dorian B.; Sweeney, Joseph P.; Ferguson, Fatima K.; Jones, Lakavious B.

    2015-01-01

    While ownership of mobile computing devices, such as cellphones, smartphones, and tablet computers, has been rapid, the adoption of these devices in K-12 classrooms has been measured. Some schools and individual teachers have integrated mobile devices to support teaching and learning. The purpose of this qualitative research was to describe the…

  2. Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

    International Nuclear Information System (INIS)

    Connor, Michael J.; Marshall, Deborah C.; Moiseenko, Vitali; Moore, Kevin; Cervino, Laura; Atwood, Todd; Sanghvi, Parag; Mundt, Arno J.; Pawlicki, Todd; Recht, Abram; Hattangadi-Gluth, Jona A.

    2017-01-01

    Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ"2 test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance, improved

  3. Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

    Energy Technology Data Exchange (ETDEWEB)

    Connor, Michael J. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Department of Radiation Oncology, University of California Irvine School of Medicine, Irvine, California (United States); Marshall, Deborah C.; Moiseenko, Vitali; Moore, Kevin; Cervino, Laura; Atwood, Todd; Sanghvi, Parag; Mundt, Arno J.; Pawlicki, Todd [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Recht, Abram [Department of Radiation Oncology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts (United States); Hattangadi-Gluth, Jona A., E-mail: jhattangadi@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States)

    2017-01-01

    Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance

  4. 30 CFR 77.510 - Resistors; location and guarding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Resistors; location and guarding. 77.510 Section 77.510 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE... COAL MINES Electrical Equipment-General § 77.510 Resistors; location and guarding. Resistors, heaters...

  5. Effects of Mobile Devices on K-12 Students' Achievement: A Meta-Analysis

    Science.gov (United States)

    Tingir, S.; Cavlazoglu, B.; Caliskan, O.; Koklu, O.; Intepe-Tingir, S.

    2017-01-01

    In this meta-analytic study, we investigated the effects of mobile devices on student achievement in science, mathematics and reading in grades K-12. Based on our inclusion criteria, we searched the ERIC and PsycINFO databases and identified 14 peer-reviewed research articles published between 2010 and 2014. We identified the device type, subject…

  6. 28 CFR 42.510 - Discrimination prohibited.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Discrimination prohibited. 42.510 Section...-Implementation of Section 504 of the Rehabilitation Act of 1973 Employment § 42.510 Discrimination prohibited. (a) General. (1) No qualified handicapped person shall on the basis of handicap be subjected to discrimination...

  7. Flexible semi-transparent silicon (100) fabric with high-k/metal gate devices

    KAUST Repository

    Rojas, Jhonathan Prieto

    2013-01-07

    Can we build a flexible and transparent truly high performance computer? High-k/metal gate stack based metal-oxide-semiconductor capacitor devices are monolithically fabricated on industry\\'s most widely used low-cost bulk single-crystalline silicon (100) wafers and then released as continuous, mechanically flexible, optically semi-transparent and high thermal budget compatible silicon fabric with devices. This is the first ever demonstration with this set of materials which allows full degree of freedom to fabricate nanoelectronics devices using state-of-the-art CMOS compatible processes and then to utilize them in an unprecedented way for wide deployment over nearly any kind of shape and architecture surfaces. Electrical characterization shows uncompromising performance of post release devices. Mechanical characterization shows extra-ordinary flexibility (minimum bending radius of 1 cm) making this generic process attractive to extend the horizon of flexible electronics for truly high performance computers. Schematic and photograph of flexible high-k/metal gate MOSCAPs showing high flexibility and C-V plot showing uncompromised performance. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. 41 CFR 101-4.510 - Recruitment.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Recruitment. 101-4.510... Employment in Education Programs or Activities Prohibited § 101-4.510 Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring...

  9. Data processing correction of the irising effect of a fast-gating intensified charge-coupled device on laser-pulse-excited spectra

    Czech Academy of Sciences Publication Activity Database

    Ondič, Lukáš; Dohnalová, Kateřina; Pelant, Ivan; Žídek, K.; de Boer, W.D.A.M.

    2010-01-01

    Roč. 81, č. 6 (2010), 063104/1-063104/5 ISSN 0034-6748 R&D Projects: GA AV ČR KAN400100701; GA AV ČR(CZ) IAA101120804; GA MŠk LC510; GA AV ČR KJB100100903 Institutional research plan: CEZ:AV0Z10100521 Keywords : irising effect * intensifier charge-coupled device Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.598, year: 2010

  10. 31 CFR 586.510 - Transactions related to telecommunications authorized.

    Science.gov (United States)

    2010-07-01

    ... telecommunications authorized. 586.510 Section 586.510 Money and Finance: Treasury Regulations Relating to Money and... Licensing Policy § 586.510 Transactions related to telecommunications authorized. All transactions with respect to the receipt and transmission of telecommunications involving the FRY (S&M) are authorized. This...

  11. Annexin A4 fucosylation enhances its interaction with the NF-kB p50 and promotes tumor progression of ovarian clear cell carcinoma.

    Science.gov (United States)

    Wang, Huimin; Deng, Lu; Cai, Mingbo; Zhuang, Huiyu; Zhu, Liancheng; Hao, Yingying; Gao, Jian; Liu, Juanjuan; Li, Xiao; Lin, Bei

    2017-12-08

    To study the structural relationship between annexin A4 and the Lewis y antigen and compare their expression and significance in ovarian clear cell carcinoma, and to explore how annexin A4 fucose glycosylation effects the interaction between annexin A4 and NF-kB p50, and how it promotes tumour progression of ovarian clear cell carcinoma. Structural relationships between annexin A4 and Lewis y antigen were detected using immunoprecipitation. Annexin A4 and Lewis y antigen expression in various subtypes of ovarian cancer tissues was detected by immunohistochemistry, and the relation between their expression was examined. Any interactions between annexin A4 and NF-kB p50 in ovarian clear cell carcinoma were detected by co-immunoprecipitation. Then looked for changes in expression of Lewis y antigen, annexin A4, NF-kB p50 and a number of downstream related molecules before and after transfection annexin A4 or FUT1, and also analyzed changes in biological processes. Lewis y antigen is a part of annexin A4 structure. The expression rate of both annexin A4 and Lewis y antigen was significantly higher in ovarian clear cell carcinoma than in other subtypes of epithelial ovarian cancer, and are associated with the clinical stages, chemotherapy resistance and poor prognostic. The interaction between annexin A4 and NF-kB p50 promoted cell proliferation, adhesion, invasion, metastasis ability and autophagy, and inhibits apoptosis, Lewis y enhanced this interaction. Annexin A4 contains Lewis y structure, Lewis y antigen modification of annexin A4 enhances its interaction with NF-kB p50, which promotes ovarian clear cell carcinoma malignancy progression.

  12. ClearPEM: prototype PET device dedicated to breast imaging

    CERN Multimedia

    Joao Varela

    2009-01-01

    Clinical trials have begun in Portugal on a new breast imaging system (ClearPEM) using positron emission tomography (PET). The system, developed by a Portuguese consortium in collaboration with CERN and laboratories participating in the Crystal Clear collaboration, will detect even the smallest tumours and thus help avoid unnecessary biopsies.

  13. 42 CFR 435.510 - Determination of dependency.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Determination of dependency. 435.510 Section 435... ISLANDS, AND AMERICAN SAMOA Categorical Requirements for Eligibility Dependency § 435.510 Determination of dependency. For families with dependent children who are not receiving AFDC, the agency must use the...

  14. 40 CFR 158.510 - Tiered testing options for nonfood pesticides.

    Science.gov (United States)

    2010-07-01

    ... pesticides. 158.510 Section 158.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR PESTICIDES Toxicology § 158.510 Tiered testing options for nonfood pesticides. For nonfood use pesticides only, applicants have two options for generating and submitting...

  15. Insight into the molecular mechanism of yeast acetyl-coenzyme A carboxylase mutants F510I, N485G, I69E, E477R, and K73R resistant to soraphen A

    Science.gov (United States)

    Gao, Jian; Liang, Li; Chen, Qingqing; Zhang, Ling; Huang, Tonghui

    2018-02-01

    Acetyl-coenzyme A carboxylases (ACCs) is the first committed enzyme of fatty acid synthesis pathway. The inhibition of ACC is thought to be beneficial not only for diseases related to metabolism, such as type-2 diabetes, but also for infectious disease like bacterial infection disease. Soraphen A, a potent allosteric inhibitor of BC domain of yeast ACC, exhibit lower binding affinities to several yeast ACC mutants and the corresponding drug resistance mechanisms are still unknown. We report here a theoretical study of binding of soraphen A to wild type and yeast ACC mutants (including F510I, N485G, I69E, E477R, and K73R) via molecular dynamic simulation and molecular mechanics/generalized Born surface area free energy calculations methods. The calculated binding free energies of soraphen A to yeast ACC mutants are weaker than to wild type, which is highly consistent with the experimental results. The mutant F510I weakens the binding affinity of soraphen A to yeast ACC mainly by decreasing the van der Waals contributions, while the weaker binding affinities of Soraphen A to other yeast ACC mutants including N485G, I69E, E477R, and K73R are largely attributed to the decreased net electrostatic (ΔE ele + ΔG GB) interactions. Our simulation results could provide important insights for the development of more potent ACC inhibitors.

  16. Diet - clear liquid

    Science.gov (United States)

    ... Group. Clear liquid diet. In: Morrison. Manual of Clinical Nutrition Management. Updated 2013. bscn2k15.weebly.com/uploads/1/2/9/2/12924787/manual_of_clinical_nutrition2013.pdf . Accessed August 20, 2016. Schattner MA, ...

  17. 20 CFR 405.510 - Claims remanded by a Federal court.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Claims remanded by a Federal court. 405.510 Section 405.510 Employees' Benefits SOCIAL SECURITY ADMINISTRATION ADMINISTRATIVE REVIEW PROCESS FOR ADJUDICATING INITIAL DISABILITY CLAIMS Judicial Review § 405.510 Claims remanded by a Federal court. When a...

  18. 76 FR 62072 - Center for Devices and Radiological Health; Standard Operating Procedures for Network of Experts...

    Science.gov (United States)

    2011-10-06

    ... Utilization of Science in Regulatory Decision Making (Task Force) and the 510(k) Working Group were... can take to enhance our 510(k) decision making. The Task Force was charged with making recommendations... technologies, and new scientific methods--into its decision making in as predictable a manner as is practical...

  19. 21 CFR 358.510 - Corn and callus remover active ingredients.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Corn and callus remover active ingredients. 358.510 Section 358.510 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... USE Corn and Callus Remover Drug Products § 358.510 Corn and callus remover active ingredients. The...

  20. Purification and characterization of plantaricin Y, a novel bacteriocin produced by Lactobacillus plantarum 510.

    Science.gov (United States)

    Chen, Yi-sheng; Wang, Yan-chong; Chow, Yiou-shing; Yanagida, Fujitoshi; Liao, Chen-chung; Chiu, Chi-ming

    2014-03-01

    Lactobacillus plantarum 510, previously isolated from a koshu vineyard in Japan, was found to produce a bacteriocin-like inhibitory substance which was purified and characterized. Mass spectrometry analysis showed that the mass of this bacteriocin is 4,296.65 Da. A partial sequence, NH2- SSSLLNTAWRKFG, was obtained by N-terminal amino acid sequence analysis. A BLAST search revealed that this is a unique sequence; this peptide is thus a novel bacteriocin produced by Lactobacillus plantarum 510 and was termed plantaricin Y. Plantaricin Y shows strong inhibitory activity against Listeria monocytogenes BCRC 14845, but no activity against other pathogens tested. Bacteriocin activity decreased slightly after autoclaving (121 °C for 15 min), but was completely inactivated by protease K. Furthermore, trypsin-digested bacteriocin product fragments retained activity against L. monocytogenes BCRC 14845 and exhibited a different inhibitory spectrum.

  1. 20 CFR 628.510 - Intake, referrals and targeting.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Intake, referrals and targeting. 628.510 Section 628.510 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR PROGRAMS... training have been provided subsequent to the objective assessment. (g) The SDA's method of meeting the...

  2. Medical device registration, agreements on mutual recognition - a step forward to global harmonization?

    International Nuclear Information System (INIS)

    Eidenberger, R.Reiner

    2000-01-01

    The purpose of this article is to give a short overview of some different regulations in Europe and the United States with regard to the clearance of medical devices and to give an outlook of what the Agreements on Mutual Recognition will bring in terms of Global Harmonization. Recent European legislation, the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices (Medical Device Directive, MDD), requires that all medical devices placed on the European market bear the CE marking. From 14 June 1998, medical devices fall under the scope of this European Medical Device Directive and there is a harmonization within the European market. Similar to this, but for another market, are the USA FDA requirements, Premarket Approval (PMA) and Premarket notification (510(k)). The same medical device, the same goal - a safe product - but different legislation and thus duplication of registration procedures. The European Commission is presently discussing a series of agreements with third countries, Australia, New Zealand, USA, Canada, Japan and Eastern European countries wishing to join the EU, concerning the mutual acceptance of inspection bodies and, ultimately, proof of conformity (for example reports on examination, certificates, licenses and marks of conformity) in connection with medical devices. Meanwhile agreements with Australia, New Zealand, USA and Canada came into force. (author)

  3. Clear Castable Polyurethane Elastomer for Fabrication of Microfluidic Devices

    Science.gov (United States)

    Domansky, Karel; Leslie, Daniel C.; McKinney, James; Fraser, Jacob P.; Sliz, Josiah D.; Hamkins-Indik, Tiama; Hamilton, Geraldine A.; Bahinski, Anthony; Ingber, Donald E.

    2013-01-01

    Polydimethylsiloxane (PDMS) has numerous desirable properties for fabricating microfluidic devices, including optical transparency, flexibility, biocompatibility, and fabrication by casting; however, partitioning of small hydrophobic molecules into the bulk of PDMS hinders industrial acceptance of PDMS microfluidic devices for chemical processing and drug development applications. Here we describe an attractive alternative material that is similar to PDMS in terms of optical transparency, flexibility and castability, but that is also resistant to absorption of small hydrophobic molecules. PMID:23954953

  4. 46 CFR 401.510 - Operation without Registered Pilots.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Operation without Registered Pilots. 401.510 Section 401... REGULATIONS Penalties; Operations Without Registered Pilots § 401.510 Operation without Registered Pilots. (a... Registered Pilot when the vessel or its cargo is in distress or jeopardy. (b) A vessel may be navigated in...

  5. 3-Aminomethyl derivatives of 4,11-dihydroxynaphtho[2,3-f]indole-5,10-dione for circumvention of anticancer drug resistance.

    Science.gov (United States)

    Shchekotikhin, Andrey E; Shtil, Alexander A; Luzikov, Yuri N; Bobrysheva, Tatyana V; Buyanov, Vladimir N; Preobrazhenskaya, Maria N

    2005-03-15

    A series of 3-aminomethyl derivatives of 4,11-dihydroxynaphtho[2,3-f]indole-5,10-dione was synthesized by Mannich reaction or by the transamination of 3-dimethylaminomethyl 4,11-dihydroxy- or 4,11-dimethoxynaphtho[2,3-f]indole-5,10-dione. The potency of novel derivatives was tested on a National Cancer Institute panel of 60 human tumor cell lines as well as in cells with genetically defined determinants of cytotoxic drug resistance, P-glycoprotein (Pgp) expression, and p53 inactivation. Mannich derivatives of 4,11-dihydroxynaphtho[2,3-f]indole-5,10-dione with an additional amino function in their side chain, demonstrated equal cytotoxicity against the parental K562 leukemia cells and their Pgp-positive subline, whereas the latter showed approximately 7-fold resistance to adriamycin, a Pgp transported drug. 3-(1-Piperazinyl)methyl and 3-(quinuclidin-3-yl)aminomethyl derivatives of 4,11-dihydroxynaphtho[2,3-f]indole-5,10-dione killed HCT116 colon carcinoma cells (carrying wild type p53) and their p53-null variant within the similar range of concentrations. We conclude that Mannich modification of 4,11-dihydroxynaphtho[2,3-f]indole-5,10-dione, especially when cyclic diamine (e.g., piperazine, quinuclidine) is used, confers an important feature to the resulting compounds, namely, the potency for tumor cells otherwise resistant to a variety of anticancer drugs.

  6. 12 CFR 510.2 - Provisions related to regulations of the Office.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Provisions related to regulations of the Office. 510.2 Section 510.2 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY MISCELLANEOUS ORGANIZATIONAL REGULATIONS § 510.2 Provisions related to regulations of the Office. (a) Amendments. The Office expressly reserves the righ...

  7. Spectral and diurnal variations in clear sky planetary albedo

    Science.gov (United States)

    Briegleb, B.; Ramanathan, V.

    1982-01-01

    Spectral and diurnal variations in the clear sky planetary albedo of the earth are calculated using a radiative transfer model to obtain January and July values for a 5 deg x 5 deg global grid. The model employs observed climatological values of temperatures, humidities, snow and sea-ice cover. The diurnal cycle of clear sky albedo is calculated in the following intervals: 0.2-0.5, 0.5-0.7, and 0.7-4 microns. Observed ozone distribution is specified as a function of latitude and season. The 0.2-0.5 micron spectral albedo is 10-20% higher than the total albedo for all latitudes because of Rayleigh scattering; the 0.5-0.7 micron albedo differs from the total albedo by 1-2% for most latitudes, while the 0.7-4 micron albedo is 5-10% lower than the total because of strong atmospheric absorption. Planetary albedo decreases from morning to local noon, with diurnal variations being particularly strong over water.

  8. Investigation of a 10 kWh sorption heat storage device for effective utilization of low-grade thermal energy

    International Nuclear Information System (INIS)

    Zhao, Y.J.; Wang, R.Z.; Li, T.X.; Nomura, Y.

    2016-01-01

    Heating and domestic hot water for family houses represents a notable share of energy consumption. However, sufficient space for the installation of thermal energy storage (TES) components may not be available in family houses or urban areas, where space may be restricted and expensive. Sorption TES devices seem to be a promising means of replacing conventional TES devices and reducing the occupied space for its high energy density. In this paper, a 10 kWh short-term sorption TES device was developed and investigated. The employed composite sorbent was formed from lithium chloride (LiCl) with the addition of expanded graphite (EG). The principle of sorption TES for the LiCl/water working pair is first illustrated. This prototype was tested under conditions representative of transition or winter seasons. Under the conditions used (charging temperature T_c_h_a at 85 °C, discharging temperature T_d_i_s at 40 °C, condensing temperature T_c at 18 °C, and evaporating temperature T_e at 30 °C), the heat storage capacity can reach 10.25 kWh, of which sorption heat accounts for approximately 60%. The heat storage density obtained was 873 Wh per kg of composite sorbent or 65.29 kWh/m"3, while the heat storage density of hot water tank was about 33.02 kWh/m"3. - Highlights: • A 10 kWh short-term sorption thermal energy device was developed. • The device was tested under conditions of transition and winter seasons. • The performance of the device was improved by recovering waste heat. • The sorption thermal energy device was compared with a 300-L hot water tank.

  9. Cooling performance of R510A in domestic water purifiers

    International Nuclear Information System (INIS)

    Park, Ki Jung; Lee, Yo Han; Jung, Dong Soo

    2010-01-01

    Cooling performance of R510A is examined both numerically and experimentally in an effort to replace HFC134a in the refrigeration system of domestic water purifiers. Although the use of HFC134a is currently dominant, it is being phased out in Europe and most developed countries due to its high potential contribution to global warming. To solve this problem, cycle simulation and experimental measurements are conducted with a new refrigerant mixture of 88%RE170/12%R600a using actual domestic water purifiers. This mixture has been recently numbered and listed as R510A by ASHRAE. Test results show that, due to the small internal volume of the refrigeration system of the domestic water purifiers, system performance with R510A is greatly influenced by the amount of charge. With the optimum charge amount of 20 to 21 g, approximately 50% that of HFC134a, the energy consumption of R510A is 22.3% lower than that of HFC134a. The compressor discharge temperature of R510A is 3.7 .deg. C lower than that of HFC134a at the optimum charge. Overall, R510A, a new, long term, and environmentally safe refrigerant, is a good alternative for HFC134a. Furthermore, it requires only minor changes in the refrigeration system of the domestic water purifiers

  10. 7 CFR 1755.510 - Construction and assembly unit drawings.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Construction and assembly unit drawings. 1755.510..., AND STANDARD CONTRACT FORMS § 1755.510 Construction and assembly unit drawings. (a) The construction and assembly unit drawings in this section shall be used by borrowers to assist the installer in...

  11. 13 CFR 108.510 - SBA approval of NMVC Company's Investment Adviser/Manager.

    Science.gov (United States)

    2010-01-01

    ... Investment Adviser/Manager. 108.510 Section 108.510 Business Credit and Assistance SMALL BUSINESS... and Compensation § 108.510 SBA approval of NMVC Company's Investment Adviser/Manager. You may employ an Investment Adviser/Manager who will be subject to the supervision of your board of directors...

  12. 20 CFR 669.510 - What planning documents must an NFJP grantee submit?

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false What planning documents must an NFJP grantee submit? 669.510 Section 669.510 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF... Accountability, Planning and Waiver Provision § 669.510 What planning documents must an NFJP grantee submit? Each...

  13. 42 CFR 422.510 - Termination of contract by CMS.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Termination of contract by CMS. 422.510 Section 422... Advantage Organizations § 422.510 Termination of contract by CMS. (a) Termination by CMS. CMS may at any time terminate a contract if CMS determines that the MA organization meets any of the following: (1...

  14. The Strange Use of דגל in Song of Songs 5:10

    OpenAIRE

    Andruska, Jennifer

    2017-01-01

    The use of the word דגל in the Song of Songs 5:10 has caused considerable confusion among commentators. Most occurrences of the word in the Song are thought to be related to an army or host carrying banners, except in 5:10, where this usage is said to make little sense. Scholars therefore interpret the woman’s use of דגל in 5:10 differently from when the man uses it to describe her awe-striking an unnerving appearance in 6:4 and 6:10. This has given some the impression that the lovers view ea...

  15. 29 CFR 510.20 - Wage surveys in Puerto Rico.

    Science.gov (United States)

    2010-07-01

    ... IMPLEMENTATION OF THE MINIMUM WAGE PROVISIONS OF THE 1989 AMENDMENTS TO THE FAIR LABOR STANDARDS ACT IN PUERTO... qualify for an extended minimum wage phase-in, the government of Puerto Rico would be required to furnish... 29 Labor 3 2010-07-01 2010-07-01 false Wage surveys in Puerto Rico. 510.20 Section 510.20 Labor...

  16. Improvements in or relating to fluid operated devices for moving articles

    International Nuclear Information System (INIS)

    Rogerson, Victor.

    1986-01-01

    The patent relates to fluid operated devices for moving articles. The machine may be used in filling a nuclear fuel canister with fuel pellets where there is a tendency for out of squareness of pellets to produce a jam condition readily cleared by a modest force. (U.K.)

  17. 78 FR 14015 - Medical Devices; Exemption From Premarket Notification; Class II Devices; Powered Patient Transport

    Science.gov (United States)

    2013-03-04

    ... CFR part 807) require persons who propose to begin the introduction or delivery for introduction into... the Canadian Standards Association (CSA)/ASME standard ``CSA B44.1/ASME A17.5 Elevator and Escalator Electrical Equipment'' for elevator and escalator equipment. FDA has assessed the need for 510(k) clearance...

  18. A Clustering K-Anonymity Privacy-Preserving Method for Wearable IoT Devices

    Directory of Open Access Journals (Sweden)

    Fang Liu

    2018-01-01

    Full Text Available Wearable technology is one of the greatest applications of the Internet of Things. The popularity of wearable devices has led to a massive scale of personal (user-specific data. Generally, data holders (manufacturers of wearable devices are willing to share these data with others to get benefits. However, significant privacy concerns would arise when sharing the data with the third party in an improper manner. In this paper, we first propose a specific threat model about the data sharing process of wearable devices’ data. Then we propose a K-anonymity method based on clustering to preserve privacy of wearable IoT devices’ data and guarantee the usability of the collected data. Experiment results demonstrate the effectiveness of the proposed method.

  19. 38 CFR 23.510 - Recruitment.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Recruitment. 23.510... Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees. Where a recipient has been found to be presently...

  20. 36 CFR 1211.510 - Recruitment.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Recruitment. 1211.510 Section... Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees. Where a recipient has been found to be presently...

  1. 18 CFR 1317.510 - Recruitment.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Recruitment. 1317.510... Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees. Where a recipient has been found to be presently...

  2. 13 CFR 113.510 - Recruitment.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Recruitment. 113.510 Section 113... Recruitment. (a) Nondiscriminatory recruitment and hiring. A recipient shall not discriminate on the basis of sex in the recruitment and hiring of employees. Where a recipient has been found to be presently...

  3. 33 CFR 183.510 - Fuel tanks.

    Science.gov (United States)

    2010-07-01

    ... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.510 Fuel tanks. (a) Each fuel tank in a boat must have been tested by its manufacturer under § 183.580 and not leak when...

  4. 40 CFR 600.510-08 - Calculation of average fuel economy.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Calculation of average fuel economy. 600.510-08 Section 600.510-08 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy Regulations for Model Year 1978 Passenger Automobiles...

  5. 40 CFR 600.510-93 - Calculation of average fuel economy.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Calculation of average fuel economy. 600.510-93 Section 600.510-93 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy Regulations for Model Year 1978 Passenger Automobiles...

  6. 40 CFR 600.510-86 - Calculation of average fuel economy.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Calculation of average fuel economy. 600.510-86 Section 600.510-86 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy Regulations for Model Year 1978 Passenger Automobiles...

  7. 21 CFR 510.110 - Antibiotics used in food-producing animals.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Antibiotics used in food-producing animals. 510... Rulings and Decisions § 510.110 Antibiotics used in food-producing animals. (a) The Food and Drug... has requested an evaluation of the public health aspects of the use of antibiotics in veterinary...

  8. p-p analyzing power excitation function between 510 and 725 MeV

    International Nuclear Information System (INIS)

    Beurtey, R.; Arvieux, J.; Boivin, M.; Boyard, J.L.; Durand, J.M.; Combes-Comets, M.P.; Courtat, P.; Gacougnolle, R.; Le Bornec, Y.; Garcon, M.

    1993-01-01

    In an earlier experiment some evidence was observed for narrow dibaryons in the analyzing power excitation function of p-p elastic scattering at √s=2160 MeV and 2192 MeV, with width Γ≅13-14 MeV. A different procedure has been carried out at the SATURNE synchrotron, in order to obtain a very high accuracy of the analyzing power for a large number of energies between 510 and 725 MeV. The results show no evidence for any structure with width ∼5 to 20 MeV. The reasons at the difference between the two experiments are discussed. (K.A.) 2 refs., 3 figs

  9. 13 CFR 107.510 - SBA approval of Licensee's Investment Adviser/Manager.

    Science.gov (United States)

    2010-01-01

    ... Investment Adviser/Manager. 107.510 Section 107.510 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION SMALL BUSINESS INVESTMENT COMPANIES Managing the Operations of a Licensee Management and... management contract. SBA's approval of an Investment Adviser/Manager for one Licensee does not indicate...

  10. 20 CFR 667.510 - What is the Grant Officer resolution process?

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false What is the Grant Officer resolution process? 667.510 Section 667.510 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF... agreement and those where there is disagreement with the recipient's resolution, including the allowability...

  11. Medical Device Recalls in Radiation Oncology: Analysis of US Food and Drug Administration Data, 2002-2015.

    Science.gov (United States)

    Connor, Michael J; Tringale, Kathryn; Moiseenko, Vitali; Marshall, Deborah C; Moore, Kevin; Cervino, Laura; Atwood, Todd; Brown, Derek; Mundt, Arno J; Pawlicki, Todd; Recht, Abram; Hattangadi-Gluth, Jona A

    2017-06-01

    To analyze all recalls involving radiation oncology devices (RODs) from the US Food and Drug Administration (FDA)'s recall database, comparing these with non-radiation oncology device recalls to identify discipline-specific trends that may inform improvements in device safety. Recall data on RODs from 2002 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems). Outcomes included determined cause of recall, recall class (severity), quantity in commerce, time until recall termination (date FDA determines recall is complete), and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by Pearson χ 2 test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. There were 502 ROD recalls and 9534 other class II device recalls during 2002 to 2015. Most recalls were for external beam devices (66.7%) and planning systems (22.9%), and recall events peaked in 2011. Radiation oncology devices differed significantly from other devices in all recall outcomes (P≤.04). Recall cause was commonly software related (49% vs 10% for other devices). Recall severity was more often moderate among RODs (97.6% vs 87.2%) instead of severe (0.2% vs 4.4%; Panalysis of recall data can identify areas for device improvement, such as better system design among RODs. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Instrument evaluation no. 18. Mini instruments contamination meter type 5.10 EL

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1980-04-01

    An evaluation is given of the general purpose contamination monitor, the Mini-Instruments Type 5-10EL which comprises a probe connected by a coiled extensible cable to a ratemeter. The facilities and controls, radiation characteristics, electrical characteristics, environmental effects, mechanical characteristics, and the manual are considered. A summary is given of the instrument's performance showing that it is a useful general-purpose contamination monitor suitable for the monitoring of beta contamination at a level for non-active areas of 1 DL (3.7 Bq cm -2 (10 -4 μCi cm -2 )) for beta emitters of maximum energy at least that of 14 C, given a normal environmental gamma background. (U.K.)

  13. 29 CFR 510.22 - Industries eligible for minimum wage phase-in.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Industries eligible for minimum wage phase-in. 510.22... REGULATIONS IMPLEMENTATION OF THE MINIMUM WAGE PROVISIONS OF THE 1989 AMENDMENTS TO THE FAIR LABOR STANDARDS ACT IN PUERTO RICO Classification of Industries § 510.22 Industries eligible for minimum wage phase-in...

  14. Bidirectional reconfiguration and thermal tuning of microcantilever metamaterial device operating from 77 K to 400 K

    Science.gov (United States)

    Pitchappa, Prakash; Manjappa, Manukumara; Krishnamoorthy, Harish N. S.; Chang, Yuhua; Lee, Chengkuo; Singh, Ranjan

    2017-12-01

    We experimentally report the bidirectional reconfiguration of an out-of-plane deformable microcantilever based metamaterial for advanced and dynamic manipulation of terahertz waves. The microcantilever is made of a bimaterial stack with a large difference in the coefficient of thermal expansion of the constituent materials. This allows for the continuous deformation of microcantilevers in upward or downward direction in response to positive or negative temperature gradient, respectively. The fundamental resonance frequency of the fabricated microcantilever metamaterial is measured at 0.4 THz at room temperature of 293 K. With decreasing temperature, the resonance frequency continuously blue shifts by 30 GHz at 77 K. On the other hand, with increasing temperature, the resonance frequency gradually red shifts by 80 GHz and saturates at 0.32 THz for 400 K. Furthermore, as the temperature is increased above room temperature, which results in the downward actuation of the microcantilever, a significant resonance line-narrowing with an enhanced quality factor is observed due to tight field confinement in the metamaterial structure. The thermal control of the microcantilever possesses numerous inherent advantages such as enhanced tunable range (˜37.5% in this work compared to previously reported microcantilever metamaterials), continuous tunability, and repeatable operations. The microcantilever metamaterial also shows high robustness to operate at cryogenic conditions and hence opens up the possibility of using meta-devices in harsh environments such as space, polar, and deep sea applications.

  15. Design of closed-loop nitrogen Joule-Thomson refrigeration cycle for 67 K with sub-atmospheric device

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C.; Lee, J.; Jeong, S. [Cryogenic Engineering Laboratory, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2013-05-15

    Closed-loop J-T (Joule-Thomson) refrigeration cycle is advantageous compared to common open loop N{sub 2} decompression system in terms of nitrogen consumption. In this study, two closed-loop pure N{sub 2} J-T refrigeration systems with sub-atmospheric device for cooling High Temperature Superconductor (HTS) power cable are investigated. J-T cooling systems include 2-stage compressor, 2-stage precooling cycle, J-T valve and a cold compressor or an auxiliary vacuum pump at the room temperature. The cold compressor and the vacuum pump are installed after the J-T valve to create sub-atmospheric condition. The temperature of 67 K is possible by lowering the pressure up to 24 kPa at the cold part. The optimized hydrocarbon mixed refrigerant (MR) J-T system is applied for precooling stage. The cold head of precooling MR J-T have the temperature from 120 K to 150 K. The various characteristics of cold compressor are investigated and applied to design parameter of the cold compressor. The Carnot efficiency of cold compressor system is calculated as 16.7% and that of vacuum pump system as 16.4%. The efficiency difference between the cold compressor system and the vacuum pump system is due to difference of enthalpy change at cryogenic temperature, enthalpy change at room temperature and different work load at the pre-cooling cycle. The efficiency of neon-nitrogen MR J-T system is also presented for comparison with the sub-atmospheric devices. These systems have several pros and cons in comparison to typical MR J-T systems such as vacuum line maintainability, system's COP and etc. In this paper, the detailed design of the subcooled N{sub 2} J-T systems are examined and some practical issues of the sub-atmospheric devices are discussed.

  16. Reconstruction of Clear-PEM data with STIR

    CERN Document Server

    Martins, M V; Rodrigues, P; Trindade, A; Oliveira, N; Correia, M; Cordeiro, H; Ferreira, N C; Varela, J; Almeida, P

    2006-01-01

    The Clear-PEM scanner is a device based on planar detectors that is currently under development within the Crystal Clear Collaboration, at CERN. The basis for 3D image reconstruction in Clear-PEM is the software for tomographic image reconstruction (STIR). STIR is an open source object-oriented library that efficiently deals with the 3D positron emission tomography data sets. This library was originally designed for the traditional cylindrical scanners. In order to make its use compatible with planar scanner data, new functionalities were introduced into the library's framework. In this work, Monte Carlo simulations of the Clear-PEM scanner acquisitions were used as input for image reconstruction with the 3D OSEM algorithm available in STIR. The results presented indicate that dual plate PEM data can be accurately reconstructed using the enhanced STIR framework.

  17. 21 CFR 172.510 - Natural flavoring substances and natural substances used in conjunction with flavors.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Natural flavoring substances and natural substances used in conjunction with flavors. 172.510 Section 172.510 Food and Drugs FOOD AND DRUG ADMINISTRATION....510 Natural flavoring substances and natural substances used in conjunction with flavors. Natural...

  18. 30 CFR 5.10 - Purpose and scope.

    Science.gov (United States)

    2010-07-01

    ... MINING PRODUCTS FEES FOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS § 5.10 Purpose and scope... control and security and document preparation directly supporting application processing; (3) A... is in support of application processing; and (4) Amortization of facility improvements and...

  19. Guide to preemption of state-law claims against Class III PMA medical devices.

    Science.gov (United States)

    Whitney, Daniel W

    2010-01-01

    There is a perception that the express preemption holding of the Supreme Court in Riegel v. Medtronic, 552 U.S. 312(2008), immunizes medical device manufacturers from common law personal injury actions involving Class III devices that received FDA clearance under a premarket approval application (PMA). In the aftermath of Riegel, many lawsuits involving Class III PMA devices have been dismissed by district courts applying the new heightened pleading standard of Bell Atlantic Corp. v. Twombly, 550 U.S. 544 (2007). Other lawsuits involving Class III PMA devices premised on fraud-on-FDA have been dismissed based on the implied preemption holding of the Supreme Court in Buckman v. Plaintiffs' Legal Comm., 531 U.S. 341 (2001). When these decisions are carefully analyzed together with Medtronic, Inc. v. Lohr, 518 U.S. 470 (1996), which found no preemption regarding a Class III device receiving FDA clearance through the 510(k) mechanism, it is apparent that the preemption defense does not apply universally to Class III PMA devices. The overall methodology for framing a non-preempted claim is to first identify conduct which violated the PMA or other specific requirements related to safety or efficacy. If such conduct can also be stated in terms of a breach of a parallel common law duty (e.g, failure to warn under strict liability or negligence, manufacturing defect or breach of warranty), then it would appear the claim is not preempted. Alternatively, regardless of a specific violation, common law remedies are not preempted by general CGMP requirements.

  20. 20 CFR 638.510 - Health care and services.

    Science.gov (United States)

    2010-04-01

    ... UNDER TITLE IV-B OF THE JOB TRAINING PARTNERSHIP ACT Center Operations § 638.510 Health care and services. The center operator shall provide a health program, including basic medical, dental, and mental...

  1. Clear-PEM, a dedicated PET camera for mammography

    CERN Document Server

    Lecoq, P

    2002-01-01

    Preliminary results suggest that Positron Emission Mammography (PEM) can offer a noninvasive method for the diagnosis of breast cancer. Metabolic images from PEM contain unique information not available from conventional morphologic imaging techniques and aid in expeditiously establishing the diagnosis of cancer. A dedicated machine seems to offer better perspectives in terms of position resolution and sensitivity. This paper describes the concept of Clear-PEM, the system presently developed by the Crystal Clear Collaboration at CERN for an evaluation of this approach. This device is based on new crystals introduced by the Crystal Clear as well as on modern data acquisition techniques developed for the large experiments in high energy physics experiments.

  2. Speech-Generating Devices versus Manual Signing for Children with Developmental Disabilities

    Science.gov (United States)

    van der Meer, Larah; Kagohara, Debora; Achmadi, Donna; O'Reilly, Mark F.; Lancioni, Giulio E.; Sutherland, Dean; Sigafoos, Jeff

    2012-01-01

    We compared speed of acquisition and preference for using a speech-generating device (SGD) versus manual signing (MS) as augmentative and alternative communication (AAC) options. Four children with developmental disabilities (DD), aged 5-10 years, were taught to request preferred objects using an iPod[R]-based SGD and MS. Intervention was…

  3. Theoretical Study of the Endogenous Production of N-13 in 115 kJ Plasma Focus Device Using Methane Gas

    Science.gov (United States)

    Faghih Haghani, Saeedeh; Sadighzadeh, A.; Talaei, A.; Zaeem, A. A.; Sadat Kiai, S. M.; Heydarnia, A.; Damideh, V.

    2013-08-01

    Mather type plasma focus device with the bank energy of 115 kJ (40 kV, 144μF) was studied for induced activity of N-13; a short-lived radioisotope β+ emitter with 511 keV of gamma rays and has a half-life of t1/2 = 9.93 min through 12C (d, n)13N nuclear reaction. N-13 radioisotope is used in Positron Emission Tomography (PET) for imaging and treatment. In this paper endogenous production of 13N is considered. It is shown by adding 3-4 % CH4 to the chamber, the induced activity of N-13 has increased about 4 %. Our study is representative of producing 106 - 109 Bq induced activity of this SLR in IR-MPF-100 device.

  4. Malrotation of the McGhan Style 510 prosthesis.

    NARCIS (Netherlands)

    Schots, J.M.; Fechner, M.R.; Hoogbergen, M.M.; Tits, H.W.H.J.

    2010-01-01

    BACKGROUND: Anatomically shaped cohesive silicone breast implants are frequently used in aesthetic and reconstructive surgery. After successful results with the Style 410 prosthesis, McGhan (Natrelle, Allergan) introduced the Style 510 prosthesis. After using this novel prosthesis, the authors

  5. IE Information Notice No. 85-64: BBC Brown Boveri low-voltage K-line circuit breakers, with deficient overcurrent trip devices models OD-4 and 5

    International Nuclear Information System (INIS)

    Jordan, E.L.

    1992-01-01

    On May 13, 1985, BBC Brown Boveri Inc. (BBC) made a 10 CFR Part 21 report to the NRC concerning a deficiency in the Models OD-4 and OD-5 overcurrent trip devices installed on K-line circuit breakers. The affected breakers were manufactured by BBC from October 1983 to March 1985 and may have incorrect short time delay band levers (links) installed in electromechanical overcurrent trip device models OD-4 and OD-5. The incorrect link could limit the travel of the short time armature and cause the short time element to be inoperative in the maximum (MAX) band. The May 13, 1985, report recommended that all K-line circuit breakers with the OD-4 and OD-5 overcurrent trip devices and any spare OD-4 and OD-5 overcurrent trip devices that were manufactured between October 1983 and March 1985, be inspected for an incorrect short time delay band link. Licensees known by BBC to have purchased K-line breakers or spare OD-4 or OD-5 overcurrent trip devices were notified of the possible defect and instructions provided for their inspection. Enclosed is a list of utilities and related facilities that were notified by BBC. However, BBC advised the NRC that there is a possibility that other utilities could be using K-line circuit breakers with the suspect OD-4 and OD-5 overcurrent trip devices. Therefore, all licensees are being notified of this possible defect

  6. 42 CFR 414.510 - Laboratory date of service for clinical laboratory and pathology specimens.

    Science.gov (United States)

    2010-10-01

    ... and pathology specimens. 414.510 Section 414.510 Public Health CENTERS FOR MEDICARE & MEDICAID... date of service for clinical laboratory and pathology specimens. The date of service for either a clinical laboratory test or the technical component of physician pathology service is as follows: (a...

  7. 12 CFR 510.5 - Release of unpublished OTS information.

    Science.gov (United States)

    2010-01-01

    ... ORGANIZATIONAL REGULATIONS § 510.5 Release of unpublished OTS information. (a) Scope. (1) This section applies to... their official capacities. Examples of unpublished information include: (i) Information in the memory of...

  8. Surface modification study of zirconium on exposure to fusion grade plasma in an 11.5 kJ plasma focus device

    International Nuclear Information System (INIS)

    Srivastava, Rohit; Niranjan, Ram; Rout, R.K.; Kaushik, T.C.; Chakravarthy, Y.; Mishra, P.

    2017-01-01

    In continuation of our investigation on effect of fusion grade plasma produced in an existing MEPF-12 (11.5 kJ, 40 μF, 24 kV) plasma focus (PF) facility on different materials, likely to be used in future fusion reactors, we have reported here the study on Zirconium (Zr) metal. In the present work, the Zr sample in disc (2 mm thick, 10 mm diameter) form was exposed to twenty shots of plasma focus operated at 4 mbar deuterium gas filling pressure and 11.5 kJ bank energy. The samples were placed at a distance of 6 cm from the tip of the anode in the MEPF-12 PF device. The emissions from the device comprise of deuterium ions in wide energy range (a few keV to several hundreds of keV), high temperature plasma (in general a few keV) and neutrons of 2.45 MeV energy produced due to D(D, 3 He)n fusion reactions

  9. 21 CFR 510.7 - Consignees of new animal drugs for use in the manufacture of animal feed.

    Science.gov (United States)

    2010-04-01

    ... manufacture of animal feed. 510.7 Section 510.7 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Provisions § 510.7 Consignees of new animal drugs for use in the manufacture of animal feed. (a) A new animal drug intended for use in the manufacture of animal feed shall be deemed to be unsafe unless at the time...

  10. Trends in Microfabrication Capabilities & Device Architectures.

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Todd [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Adam [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lentine, Tony [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mudrick, John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Okandan, Murat [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rodrigues, Arun [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-06-01

    The last two decades have seen an explosion in worldwide R&D, enabling fundamentally new capabilities while at the same time changing the international technology landscape. The advent of technologies for continued miniaturization and electronics feature size reduction, and for architectural innovations, will have many technical, economic, and national security implications. It is important to anticipate possible microelectronics development directions and their implications on US national interests. This report forecasts and assesses trends and directions for several potentially disruptive microfabrication capabilities and device architectures that may emerge in the next 5-10 years.

  11. Verkkosivuston käytettävyys : case: Tmi Niina Virtanen

    OpenAIRE

    Virtanen, Antti

    2016-01-01

    Tämän opinnäytetyön tarkoituksena oli toteuttaa responsiiviset verkkosivut case yritykselle, sekä samalla tehdä niistä käytettävyys- ja responsiivisuustutkimus. Sivuston responsiivisuutta testattiin tietokoneella, tabletilla ja puhelimella. Testauslaitteina toimivat Lenovo Ideapad Y510P, Huawei T1 ja OnePlus 3. Opinnäytetyössä perehdytään käytettävyyden teoriaan, siihen mitä se on, miten sitä voi hyödyntää ja miten sitä voi parantaa. Responsiivisuuden teoriaa ja käytäntöä on myös esitelty...

  12. 76 FR 69333 - Derivatives Clearing Organization General Provisions and Core Principles

    Science.gov (United States)

    2011-11-08

    ... Management)); 75 FR 78185 (Dec. 15, 2010) (Core Principles J, K, L, and M (Information Management)); 75 FR... Parts 1, 21, 39 et al. Derivatives Clearing Organization General Provisions and Core Principles; Final... Derivatives Clearing Organization General Provisions and Core Principles AGENCY: Commodity Futures Trading...

  13. 21 CFR 111.510 - What requirements apply when a returned dietary supplement is received?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What requirements apply when a returned dietary supplement is received? 111.510 Section 111.510 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING PRACTICE IN...

  14. 40 CFR 52.510 - Small business assistance program.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Small business assistance program. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS District of Columbia § 52.510 Small business... Regulation Administration submitted a plan for the establishment and implementation of a Small Business...

  15. 24 CFR 232.510 - Commitment and commitment fee.

    Science.gov (United States)

    2010-04-01

    ... HOUSING AND URBAN DEVELOPMENT MORTGAGE AND LOAN INSURANCE PROGRAMS UNDER NATIONAL HOUSING ACT AND OTHER AUTHORITIES MORTGAGE INSURANCE FOR NURSING HOMES, INTERMEDIATE CARE FACILITIES, BOARD AND CARE HOMES, AND... of Fire Safety Equipment Fees and Charges § 232.510 Commitment and commitment fee. (a) Issuance of...

  16. 77 FR 45927 - Implementation of Device Registration and Listing Requirements Enacted in the Public Health...

    Science.gov (United States)

    2012-08-02

    ... would also assist us in our fundamental regulatory activities, such as planning and scheduling... of labeling (or the label and package insert) and, in some cases, advertising. Section 510(j)(2) of... postmarketing surveillance programs, help ensure the safety of imported devices, improve the scheduling and...

  17. Helium ion distributions in a 4 kJ plasma focus device by 1 mm-thick large-size polycarbonate detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sohrabi, M., E-mail: dr_msohrabi@yahoo.com; Habibi, M.; Ramezani, V.

    2014-11-14

    Helium ion beam profile, angular and iso-ion beam distributions in 4 kJ Amirkabir plasma focus (APF) device were effectively observed by the unaided eyes and studied in single 1 mm-thick large-diameter (20 cm) polycarbonate track detectors (PCTD). The PCTDs were processed by 50 Hz–HV electrochemical etching using a large-size ECE chamber. The results show that helium ions produced in the APF device have a ring-shaped angular distribution peaked at an angle of ∼±60° with respect to the top of the anode. Some information on the helium ion energy and distributions is also provided. The method is highly effective for ion beam studies. - Highlights: • Helium iso-ion beam profile and angular distributions were studied in the 4 kJ APF device. • Large-area 1 mm-thick polycarbonate detectors were processed by 50 Hz-HV ECE. • Helium ion beam profile and distributions were observed by unaided eyes in a single detector. • Helium ion profile has ring-shaped distributions with energies lower at the ring location. • Helium iso-ion track density, diameter and energy distributions are estimated.

  18. 50 CFR 600.510 - Gear avoidance and disposal.

    Science.gov (United States)

    2010-10-01

    ... gear in the EEZ. (3) If these articles or substances are encountered, or in the event of accidental or... Section 600.510 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND... include: (1) The name of the reporting vessel. (2) A description of the incident and articles retrieved...

  19. A High Power Boost Converter for PV Systems Operating up to 300 kHz using SiC Devices

    DEFF Research Database (Denmark)

    Anthon, Alexander; Zhang, Zhe; Andersen, Michael A. E.

    2014-01-01

    In this paper, a 3kW boost converter for PV applications using SiC devices is introduced. Main focus is to operate the converter over a wide range of switching frequency and to analyze the main loss distributors as well as the efficiency. The switching element is a recently introduced normally...... be operated at full power for a switching frequency of 100 kHz using natural cooling. At 200 kHz the boost converter is capable of operating at full power when forced air cooling is applied having a JFET case temperature of less than 90 C. The case temperature of the JFET increases up to 110 C at a switching...

  20. Inverse spin-valve effect in nanoscale Si-based spin-valve devices

    Science.gov (United States)

    Hiep, Duong Dinh; Tanaka, Masaaki; Hai, Pham Nam

    2017-12-01

    We investigated the spin-valve effect in nano-scale silicon (Si)-based spin-valve devices using a Fe/MgO/Ge spin injector/detector deposited on Si by molecular beam epitaxy. For a device with a 20 nm Si channel, we observed clear magnetoresistance up to 3% at low temperature when a magnetic field was applied in the film plane along the Si channel transport direction. A large spin-dependent output voltage of 20 mV was observed at a bias voltage of 0.9 V at 15 K, which is among the highest values in lateral spin-valve devices reported so far. Furthermore, we observed that the sign of the spin-valve effect is reversed at low temperatures, suggesting the possibility of a spin-blockade effect of defect states in the MgO/Ge tunneling barrier.

  1. 24 CFR 982.510 - Other fees and charges.

    Science.gov (United States)

    2010-04-01

    ... DEVELOPMENT SECTION 8 TENANT BASED ASSISTANCE: HOUSING CHOICE VOUCHER PROGRAM Rent and Housing Assistance Payment § 982.510 Other fees and charges. (a) The cost of meals or supportive services may not be included... meals or supportive services. Non-payment of such charges is not grounds for termination of tenancy. (c...

  2. 20 CFR 670.510 - Are Job Corps center operators responsible for providing all vocational training?

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Are Job Corps center operators responsible for providing all vocational training? 670.510 Section 670.510 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR THE JOB CORPS UNDER TITLE I OF THE WORKFORCE INVESTMENT ACT...

  3. 77 FR 21277 - Customer Clearing Documentation, Timing of Acceptance for Clearing, and Clearing Member Risk...

    Science.gov (United States)

    2012-04-09

    ..., 23, 37, et al. Customer Clearing Documentation, Timing of Acceptance for Clearing, and Clearing..., 38, and 39 RIN 3038-0092, -0094 Customer Clearing Documentation, Timing of Acceptance for Clearing... implement new statutory provisions enacted by Title VII of the Dodd-Frank Wall Street Reform and Consumer...

  4. Autonomous miniaturised device with USB interface for pulse height analysis and multi-channel scaling (TUKAN-8K-USB)

    International Nuclear Information System (INIS)

    Guzik, Z.; Borsuk, S.; Plominski, M.; Traczyk, K.

    2005-01-01

    We present autonomous a 8K-channel miniature device designed for spectroscopy or intensity vs. time measurements. The device (TUKAN-8K-USB) is based on the USB interface, and is contained in a screened separate box - it can be proved either directly from the USB port or from an external DC source (wall adapter of battery). The device may work in two independent operational modes: Multi-Channel Analysis (MCA) and Multi-Channel Scaling (MCS). The crucial MCA component - Peak detect and Hold circuitry - is featuring a novel architecture based on a diamond transistor. Its analog stage can accept analog pulses with front edges down to 100 ns and has a differential linearity below 0.5% (full scale sliding scale averaging). Automatic stops on count in Region-Of-Interest (ROI) and on preset live or real time are implemented. The MCS works at medium speed counting rates (up to 8 MHz), with preset dwell time, number of channels and multi-sweep mode. Each these parameters can also be controlled externally. Digital interfacing is based on four used configurable logical I/O lines. A single CYCLONE EP1C3 Altera FPGA provides all control functions. The USB communication is based on FYDI FIFO controller. The analyzer is equipped with advanced, user-friendly software, which is subjected of another publication. )author)

  5. 9 CFR 590.510 - Classifications of shell eggs used in the processing of egg products.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Classifications of shell eggs used in the processing of egg products. 590.510 Section 590.510 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION INSPECTION OF EGGS AND EGG PRODUCTS...

  6. Using of explosive technologies for development of a compact current-limiting device for operation on 110 kV class systems

    Science.gov (United States)

    Shurupov, A. V.; Shurupov, M. A.; Kozlov, A. A.; Kotov, A. V.

    2016-11-01

    This paper considers the possibility of creating on new physical principles a highspeed current-limiting device (CLD) for the networks with voltage of 110 kV, namely, on the basis of the explosive switching elements. The device is designed to limit the steady short-circuit current to acceptable values for the time does not exceed 3 ms at electric power facilities. The paper presents an analysis of the electrical circuit of CLD. The main features of the scheme are: a new high-speed switching element with high regenerating voltage; fusible switching element that enables to limit the overvoltage after sudden breakage of network of the explosive switch; non-inductive resistor with a high heat capacity and a special reactor with operating time less than 1 s. We analyzed the work of the CLD with help of special software PSPICE, which is based on the equivalent circuit of single-phase short circuit to ground in 110 kV network. Analysis of the equivalent circuit operation CLD shows its efficiency and determines the CLD as a perspective direction of the current-limiting devices of new generation.

  7. Using of explosive technologies for development of a compact current-limiting device for operation on 110 kV class systems

    International Nuclear Information System (INIS)

    Shurupov, A V; Shurupov, M A; Kozlov, A A; Kotov, A V

    2016-01-01

    This paper considers the possibility of creating on new physical principles a highspeed current-limiting device (CLD) for the networks with voltage of 110 kV, namely, on the basis of the explosive switching elements. The device is designed to limit the steady short-circuit current to acceptable values for the time does not exceed 3 ms at electric power facilities. The paper presents an analysis of the electrical circuit of CLD. The main features of the scheme are: a new high-speed switching element with high regenerating voltage; fusible switching element that enables to limit the overvoltage after sudden breakage of network of the explosive switch; non-inductive resistor with a high heat capacity and a special reactor with operating time less than 1 s. We analyzed the work of the CLD with help of special software PSPICE, which is based on the equivalent circuit of single-phase short circuit to ground in 110 kV network. Analysis of the equivalent circuit operation CLD shows its efficiency and determines the CLD as a perspective direction of the current-limiting devices of new generation. (paper)

  8. 76 FR 15986 - Food and Drug Administration/Xavier University Global Medical Device Conference

    Science.gov (United States)

    2011-03-22

    ... Clinical Trials. Risk Management and Design Controls. 510(k) SE Decision Making Process. Warning Letter... responsible for subsequent changes to the Web site after this document publishes in the Federal Register. To... payment information for the fee to Xavier University, Attention: Sue Bensman, 3800 Victory Pkwy...

  9. Design of distributed JT (Joule-Thomson) effect heat exchanger for superfluid 2 K cooling device

    Science.gov (United States)

    Jeong, S.; Park, C.; Kim, K.

    2018-03-01

    Superfluid at 2 K or below is readily obtained from liquid helium at 4.2 K by reducing its vapour pressure. For better cooling performance, however, the cold energy of vaporized helium at 2 K chamber can be effectively utilized in a recuperator which is specially designed in this paper for accomplishing so-called the distributed Joule-Thomson (JT) expansion effect. This paper describes the design methodology of distributed JT effect heat exchanger for 2 K JT cooling device. The newly developed heat exchanger allows continuous significant pressure drop at high-pressure part of the recuperative heat exchanger by using a capillary tube. Being different from conventional recuperative heat exchangers, the efficient JT effect HX must consider the pressure drop effect as well as the heat transfer characteristic. The heat exchanger for the distributed JT effect actively utilizes continuous pressure loss at the hot stream of the heat exchanger by using an OD of 0.64 mm and an ID of 0.4 mm capillary tube. The analysis is performed by dividing the heat exchanger into the multiple sub-units of the heat exchange part and JT valve. For more accurate estimation of the pressure drop of spirally wound capillary tube, preliminary experiments are carried out to investigate the friction factor at high Reynolds number. By using the developed pressure drop correlation and the heat transfer correlation, the specification of the heat exchanger with distributed JT effect for 2 K JT refrigerator is determined.

  10. 40 CFR 600.510-12 - Calculation of average fuel economy and average carbon-related exhaust emissions.

    Science.gov (United States)

    2010-07-01

    ... and average carbon-related exhaust emissions. 600.510-12 Section 600.510-12 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF... Transportation. (iv) [Reserved] (2) Average carbon-related exhaust emissions will be calculated to the nearest...

  11. Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.

    Science.gov (United States)

    Wu, Meng; Keil, Andreas; Constantin, Dragos; Star-Lack, Josh; Zhu, Lei; Fahrig, Rebecca

    2014-12-01

    The overall goal of this work is to improve the computed tomography (CT) image quality for patients with metal implants or fillings by completing the missing kilovoltage (kV) projection data with selectively acquired megavoltage (MV) data that do not suffer from photon starvation. When both of these imaging systems, which are available on current radiotherapy devices, are used, metal streak artifacts are avoided, and the soft-tissue contrast is restored, even for regions in which the kV data cannot contribute any information. Three image-reconstruction methods, including two filtered back-projection (FBP)-based analytic methods and one iterative method, for combining kV and MV projection data from the two on-board imaging systems of a radiotherapy device are presented in this work. The analytic reconstruction methods modify the MV data based on the information in the projection or image domains and then patch the data onto the kV projections for a FBP reconstruction. In the iterative reconstruction, the authors used dual-energy (DE) penalized weighted least-squares (PWLS) methods to simultaneously combine the kV/MV data and perform the reconstruction. The authors compared kV/MV reconstructions to kV-only reconstructions using a dental phantom with fillings and a hip-implant numerical phantom. Simulation results indicated that dual-energy sinogram patch FBP and the modified dual-energy PWLS method can successfully suppress metal streak artifacts and restore information lost due to photon starvation in the kV projections. The root-mean-square errors of soft-tissue patterns obtained using combined kV/MV data are 10-15 Hounsfield units smaller than those of the kV-only images, and the structural similarity index measure also indicates a 5%-10% improvement in the image quality. The added dose from the MV scan is much less than the dose from the kV scan if a high efficiency MV detector is assumed. The authors have shown that it is possible to improve the image quality of

  12. 24 CFR 5.510 - Documents of eligible immigration status.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Documents of eligible immigration... Noncitizens § 5.510 Documents of eligible immigration status. (a) General. A responsible entity shall request and review original documents of eligible immigration status. The responsible entity shall retain...

  13. Microfluidic Leaching of Soil Minerals: Release of K+ from K Feldspar

    Science.gov (United States)

    Ciceri, Davide; Allanore, Antoine

    2015-01-01

    The rate of K+ leaching from soil minerals such as K-feldspar is believed to be too slow to provide agronomic benefit. Currently, theories and methods available to interpret kinetics of mineral processes in soil fail to consider its microfluidic nature. In this study, we measure the leaching rate of K+ ions from a K-feldspar-bearing rock (syenite) in a microfluidic environment, and demonstrate that at the spatial and temporal scales experienced by crop roots, K+ is available at a faster rate than that measured with conventional apparatuses. We present a device to investigate kinetics of mineral leaching at an unprecedented simultaneous resolution of space (~101-102 μm), time (~101-102 min) and fluid volume (~100-101 mL). Results obtained from such a device challenge the notion that silicate minerals cannot be used as alternative fertilizers for tropical soils. PMID:26485160

  14. A quantitative image quality comparison of four different image guided radiotherapy devices

    International Nuclear Information System (INIS)

    Stuetzel, Julia; Oelfke, Uwe; Nill, Simeon

    2008-01-01

    Purpose: A study to quantitatively compare the image quality of four different image guided radiotherapy (IGRT) devices based on phantom measurements with respect to the additional dose delivered to the patient. Methods: Images of three different head-sized phantoms (diameter 16-18 cm) were acquired with the following four IGRT-CT solutions: (i) the Siemens Primatom single slice fan beam computed tomography (CT) scanner with an acceleration voltage of 130 kV, (ii) a Tomotherapy HI-ART II unit using a fan beam scanner with an energy of 3.5 MeV and (iii) the Siemens Artiste prototype, providing the possibility to perform kV (121 kV) and MV (6 MV) cone beam (CB) CTs. For each device three scan protocols (named low, normal, high) were selected to yield the same weighted computed tomography dose index (CTDI w ). Based on the individual inserts of the different phantoms the image quality achieved with each device at a certain dose level was characterized in terms of homogeneity, spatial resolution, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and electron density-to-CT-number conversion. Results: Based on the current findings for head-sized phantoms all devices show an electron density-to-CT-number conversion almost independent of the imaging parameters and hence can be suited for treatment planning purposes. The evaluation of the image quality, however, points out clear differences due to the different energies and geometries. The Primatom standard CT scanner shows throughout the best performance, especially for soft tissue contrast and spatial resolution with low imaging doses. Reasonable soft tissue contrast can be obtained with slightly higher doses compared to the CT scanner with the kVCB and the Tomotherapy unit. In order to get similar results with the MVCB system a much higher dose needs to be applied to the patient. Conclusion: Considering the entire investigations, especially in terms of contrast and spatial resolution, a rough tendency for

  15. Is D0→phiK0 really a clear signal for the annihilation diagram

    International Nuclear Information System (INIS)

    Donoghue, J.F.

    1986-01-01

    It is shown that rescattering effects required by unitarity can produce the reaction D 0 →phiK 0 , even when the ''W-exchange'' or ''annihilation'' diagram is not present. This is addressed both in a general context and a specific model. In the latter, it is the mode D 0 →K(eta which plays the major role in generating the phiK final state, as the K(eta state is produced using the uu-bar component of the eta, and scatters, K(eta→Kphi by quark exchange, utilizing the ss-bar component of the eta

  16. Participative Teaching with Mobile Devices and Social Networks for K-12 Children

    Directory of Open Access Journals (Sweden)

    Livia Stefan

    2016-08-01

    Full Text Available This article details a set of participatory pedagogical experiments conducted within a research grant PN II IDEI (”Time Maps. Real communities, virtual worlds, experimented pasts” performed with the purpose of helping rural communities in identifying their cultural heritage andtransmitting it to the younger generations by means of modern IT technologies, including web 2.0. In a Danubian rural community, several points of archaeological interest (POIs were identified, which were then included in a geographic Augmented Reality application for smartphones and tablets. Subsequently, the geographic data were collected from the archaeological site by the K-12 children, under the coordination of an academic staff member of the National University of Arts in Bucharest, and stored on their devices using Google Maps. The augmented information provided onthe site was annotated and shared with other K-12 children, through different social networks sites (SNS and content postings. This first stage experiment was extended to the development of a social learning environment complementary to the educational site (www.timemaps.net to support thetransmission of several traditional technologies (textile, ceramic, glass in a collaborative manner. We consider that our experiments can significantly increase the visibility of the information pertaining to the identity of target places and communities among the younger generation. A mobile-learning paradigm, in combination with web 2.0 technologies, was the support for a distributed and low-cost platform for communication and collaboration. Social networks linked thearchaeological heritage and the academic research with the larger community of rural K-12 children. The article analyzes this platform as a solution for creating, collecting and sharingeducational content, and presents conclusions on using social media for effective blended learning and transmittal of the cultural heritage.

  17. 20 CFR 422.510 - Applications and related forms used in the health insurance for the aged program.

    Science.gov (United States)

    2010-04-01

    ... health insurance for the aged program. 422.510 Section 422.510 Employees' Benefits SOCIAL SECURITY... forms used in the health insurance for the aged program. (a) Application forms. The following forms are prescribed for use in applying for entitlement to benefits under the health insurance for the aged program...

  18. Surgically induced astigmatism after phacoemulsification by temporal clear corneal and superior clear corneal approach: a comparison

    Directory of Open Access Journals (Sweden)

    Nikose AS

    2018-01-01

    Full Text Available Archana Sunil Nikose, Dhrubojyoti Saha, Pradnya Mukesh Laddha, Mayuri Patil Department of Ophthalmology, N.K.P. Salve Institute and LMH, Nagpur, Maharashtra, India Introduction: Cataract surgery has undergone various advances since it was evolved from ancient couching to the modern phacoemulsification cataract surgery. Surgically induced astigmatism (SIA remains one of the most common complications. The introduction of sutureless clear corneal incision has gained increasing popularity worldwide because it offers several advantages over the traditional sutured limbal incision and scleral tunnel. A clear corneal incision has the benefit of being bloodless and having an easy approach, but SIA is still a concern.Purpose: In this study, we evaluated the SIA in clear corneal incisions with temporal approach and superior approach phacoemulsification. Comparisons between the two incisions were done using keratometric readings of preoperative and postoperative refractive status.Methodology: It was a hospital-based prospective interventional comparative randomized control trial of 261 patients conducted in a rural-based tertiary care center from September 2012 to August 2014. The visual acuity and detailed anterior segment and posterior segment examinations were done and the cataract was graded according to Lens Opacification Classification System II. Patients were divided for phacoemulsification into two groups, group A and group B, who underwent temporal and superior clear corneal approach, respectively. The patients were followed up on day 1, 7, 30, and 90 postoperatively. The parameters recorded were uncorrected visual acuity, best-corrected visual acuity, slit lamp examination, and keratometry. The mean difference of SIA between 30th and 90th day was statistically evaluated using paired t-test, and all the analyses were performed using SPSS 18.0 (SPSS Inc. software.Results: The mean postoperative SIA in group A was 0.998 D on the 30th day, which

  19. An Experimental Study of the Decay $D^0 \\to K^- K^- K^+ \\pi^+$

    Energy Technology Data Exchange (ETDEWEB)

    Devmal, Shiral Cleophas [Cincinnati U.

    2000-05-01

    Using data from the E791 experiment at Fermi National Accelerator Laboratory (Fermilab), we have studied the Cabibbo favored, but phase space suppressed decay $D^0 \\to K^-K^- K^+ \\pi^+$ with the normalization channel $D^0 \\to K^- \\pi^- \\pi^+ \\pi^+$. We report the branching ratio of $D^0 \\to K^- K^- K^+ \\pi^+$ relative to the branching ratio of $D^0 \\to K^- \\pi^- \\pi^+ \\pi^+$. This value is (0.54 $\\pm$ 0.13 $\\pm$ 0.07)%. We see a clear signal of $K^-K^+$ resonance in the decay $D^0 \\to K^-K^-K^+\\pi^+$ from which we conclude that about (60 $\\pm$ 30)% of $KKK\\pi$ comes from $D^0 \\to \\phi K^-\\pi^+; \\phi \\to K^-K^+$. We also set the range (0.30% - 0.90%) for the ratio $P_{q\\overline{q}} = P_{NoPop}$ where $P_{q\\bar{q}}$ is the contribution from either $D^0 \\to K^-K^-K^+\\pi^+$ terms that pop an $s\\bar{s}$ or corresponding $D^0 \\to K^- \\pi^- \\pi^+ \\pi^+$ terms that pop either $u\\bar{u}$ or $d\\bar{d}$ pair and $P_{NoPop}$ is the contributions from the $D^0 \\to K^- \\pi^- \\pi^+ \\pi^+$ terms that do not have such corresponding popping.

  20. Helium ion distributions in a 4 kJ plasma focus device by 1 mm-thick large-size polycarbonate detectors

    Science.gov (United States)

    Sohrabi, M.; Habibi, M.; Ramezani, V.

    2014-11-01

    Helium ion beam profile, angular and iso-ion beam distributions in 4 kJ Amirkabir plasma focus (APF) device were effectively observed by the unaided eyes and studied in single 1 mm-thick large-diameter (20 cm) polycarbonate track detectors (PCTD). The PCTDs were processed by 50 Hz-HV electrochemical etching using a large-size ECE chamber. The results show that helium ions produced in the APF device have a ring-shaped angular distribution peaked at an angle of ∼ ± 60 ° with respect to the top of the anode. Some information on the helium ion energy and distributions is also provided. The method is highly effective for ion beam studies.

  1. 13 CFR 121.510 - What is the size standard for leasing of Government land for uranium mining?

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false What is the size standard for leasing of Government land for uranium mining? 121.510 Section 121.510 Business Credit and Assistance... standard for leasing of Government land for uranium mining? A concern is small for this purpose if it...

  2. Regulation and Device Development: Tips for Optimizing Your Experience With the Food and Drug Administration.

    Science.gov (United States)

    Brooks, Steven S

    2017-06-01

    Physician-inventors are in a unique position to identify unserved patient needs, and innovate solutions to clinical problems. These solutions may also have associated commercial opportunities. The logistics of developing these medical products, however, can seem a daunting task. One of the primary barriers in the United States is the regulatory process of the Food and Drug Administration (FDA). In this article, we will explore the risk-based approach used by the FDA which forms a framework to consider the regulatory pathway and the process to gain regulatory clearance or approval for medical devices. Inherent device properties and the procedural risk of the devices will determine the rigor with which they are scrutinized by FDA, and the evidentiary requirements to legally market them. Data and evidentiary development will vary depending on risk and regulatory precedent and may or may not require clinical data This regulatory paradigm will determine into which risk-based device class they fit, and whether they are regulated under the 510(k) or premarket approval application pathways. The FDA, although gatekeeper of the US market and tasked with determining which products are safe and effective, can be a powerful ally for product development. They have significant scientific and medical expertise, and mechanisms to both provide guidance, and also to consider novel approaches to product development and evidence development. Early interaction for routine and novel products alike can result in expedited and efficient development. This collaborative approach can be best practice to most expeditiously develop the next generation of products, getting them into the hands of US doctors and into the treatment of US patients. Copyright © 2017. Published by Elsevier Inc.

  3. Measuring the diffusion of Ti and Cu in low-k materials for microelectronic devices by EELS, EFTEM and EDX

    International Nuclear Information System (INIS)

    Barnes, J-P; Lafond, D; Guedj, C; Fayolle, M; Meininger, P; Maitrejean, S; David, T; Posseme, N; Bayle-Guillemaud, P; Chabli, Amal

    2006-01-01

    The need to reduce RC delay and cross talk in Cu interconnects means that ultra low-k dielectrics such as porous SiCOH are being integrated into microelectronic devices. Unfortunately porous materials lead to integration issues such as metal diffusion into the porosity of the dielectric, especially when chemical vapour deposition (CVD) methods are used for metal deposition. In our case, the copper anti-diffusion barrier used before Cu deposition is MOCVD TiN. Without an appropriate surface treatment (pore sealing) of the low-k the TiN may diffuse in the porosity. The presence of Ti or Cu in the low-k is deleterious as it can raise the dielectric constant and the leakage current. EFTEM EELS and EDX have been used to map Ti, Cu, O and C as a function of process conditions

  4. 21 CFR 510.301 - Records and reports concerning experience with animal feeds bearing or containing new animal...

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Records and reports concerning experience with... application is in effect. 510.301 Section 510.301 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... or deterioration in the drug, or any failure of one or more distributed batches of the drug to meet...

  5. Enhancement of photovoltaic characteristics of nanocrystalline 2,3-naphthalocyanine thin film-based organic devices

    International Nuclear Information System (INIS)

    Farag, A.A.M.; Osiris, W.G.; Ammar, A.H.

    2012-01-01

    Graphical abstract: Scanning electron microscopy (SEM) image of NPC films: (a) cross section view, (b) surface morphology of the film at 300 K, (c) surface morphology of the annealed film at 350 K, (d) surface morphology of the annealed film at 400 K, (e) surface morphology of the annealed film at 450 K, and (f) surface morphology of the annealed film at 500 K. Highlights: ► The absorption edge shifts to the lower energy for the annealed NPC film. ► The device of Au/NPC/ITO exhibit rectifying characteristics. ► The devices show improvement in photovoltaic parameters. ► The power conversion efficiency of the devices show enhancement under annealing. - Abstract: In this work, nanocrystalline thin films of 2,3-naphthalocyanine (NPC) were successfully deposited by a thermal evaporation technique at room temperature under high vacuum (∼10 −4 Pa). The crystal structure and surface morphology were measured using X-ray diffraction (XRD) and scanning electron microscopy (SEM), respectively. A preferred orientation along the (0 0 1) direction was observed in all the studied films and the average crystallite size was calculated. Scanning electron miscroscopy (SEM) images of NPC films at different thermal treatment indicated significant changes on surface level patterns and gave clear evidence of agglomeration of nanocrystalline structures. The molecular structural properties of the thin films were characterized using Fourier transform infrared spectroscopy (FTIR), which revealed the stability of the chemical bonds of the compound under thermal treatment. The dark electrical conductivity of the films at various heat treatment stages showed that NPC films have a better conductivity than that of its earlier reported naphthalocyanine films and the activation energy was found to decrease with annealing temperature. The absorption edge shifted to the lower energy as a consequence of the thermal annealing of the film and the fundamental absorption edges correspond to a

  6. Teaching for Creativity by Science Teachers in Grades 5-10

    Science.gov (United States)

    Al-Abdali, Nasser S.; Al-Balushi, Sulaiman M.

    2016-01-01

    This classroom observation study explored how science teachers (N = 22) teach for creativity in grades 5-10 in Oman. We designed an observation form with 4 main categories that targeted the instructional practices related to teaching for creativity: questioning strategy, teacher's responses to students' ideas, classroom activities to support…

  7. 7 CFR 4290.510 - Approval of RBIC's Investment Adviser/Manager.

    Science.gov (United States)

    2010-01-01

    ... INVESTMENT COMPANY (âRBICâ) PROGRAM Managing the Operations of a RBIC Management and Compensation § 4290.510... approval of the management contract. Approval of an Investment Adviser/Manager for one RBIC does not... 7 Agriculture 15 2010-01-01 2010-01-01 false Approval of RBIC's Investment Adviser/Manager. 4290...

  8. 21 CFR 510.305 - Maintenance of copies of approved medicated feed mill licenses to manufacture animal feed bearing...

    Science.gov (United States)

    2010-04-01

    ... mill licenses to manufacture animal feed bearing or containing new animal drugs. 510.305 Section 510... copies of approved medicated feed mill licenses to manufacture animal feed bearing or containing new... medicated feed mill license (Form FDA 3448) on the premises of the manufacturing establishment; and (b...

  9. A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, P. K., E-mail: pkumar@ipr.res.in; Singh, S. K.; Sanyasi, A. K.; Awasthi, L. M., E-mail: kushagra.lalit@gmail.com; Mattoo, S. K. [Institute for Plasma Research, Gandhinagar (India)

    2016-07-15

    This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltage protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.

  10. 75 FR 78185 - Information Management Requirements for Derivatives Clearing Organizations

    Science.gov (United States)

    2010-12-15

    ... Principles J, K, L and M. This is based on the Commission's view that rigorous information management... COMMODITY FUTURES TRADING COMMISSION 17 CFR Parts 1, 21, and 39 RIN 3038-AC98 Information Management Requirements for Derivatives Clearing Organizations AGENCY: Commodity Futures Trading Commission...

  11. An example of a component replacement when applying ASME N509 and ASME N510 to older ventilation systems

    International Nuclear Information System (INIS)

    Arndt, T.E.

    1994-06-01

    This paper presents an example of a component replacement (electric heater) when installed in an older ventilation system that was constructed before the issuance of ASME N509 and N510. Many of the existing ventilation systems at the Hanford Site were designed, fabricated, and installed before the issuance of ASME N509 and N510. Requiring the application of these codes to existing ventilation systems presents challenges to the engineer when design changes are needed. Although it may seem that the application of ASME N509 or N510 may be a hindrance at times, this does not need to occur. Proper preparation at the start of project or design modifications can minimize frustration to the engineer when it is judged that portions of ASME N509 and N510 do not apply in a particular application

  12. 40 CFR 59.510 - What records am I required to maintain?

    Science.gov (United States)

    2010-07-01

    ... PROGRAMS (CONTINUED) NATIONAL VOLATILE ORGANIC COMPOUND EMISSION STANDARDS FOR CONSUMER AND COMMERCIAL PRODUCTS National Volatile Organic Compound Emission Standards for Aerosol Coatings § 59.510 What records... providing the written certification to the Administrator in accordance with § 59.511(g), the certifying...

  13. Experimental study of elementary collection efficiency of aerosols by spray: Design of the experimental device

    Energy Technology Data Exchange (ETDEWEB)

    Ducret, D.; Vendel, J.; Garrec. S.L.

    1995-02-01

    The safety of a nuclear power plant containment building, in which pressure and temperature could increase because of a overheating reactor accident, can be achieved by spraying water drops. The spray reduces the pressure and the temperature levels by condensation of steam on cold water drops. The more stringent thermodynamic conditions are a pressure of 5.10{sup 5} Pa (due to steam emission) and a temperature of 413 K. Moreover its energy dissipation function, the spray leads to the washout of fission product particles emitted in the reactor building atmosphere. The present study includes a large program devoted to the evaluation of realistic washout rates. The aim of this work is to develop experiments in order to determine the collection efficiency of aerosols by a single drop. To do this, the experimental device has to be designed with fundamental criteria:-Thermodynamic conditions have to be representative of post-accident atmosphere. Thermodynamic equilibrium has to be attained between the water drops and the gaseous phase. Thermophoretic, diffusiophoretic and mechanical effects have to be studied independently. Operating conditions have to be homogenous and constant during each experiment. This paper presents the design of the experimental device. In practice, the consequences on the design of each of the criteria given previously and the necessity of being representative of the real conditions will be described.

  14. Clearing of toxic substances: are there differences between the available liver support devices?

    Science.gov (United States)

    Krisper, Peter; Stadlbauer, Vanessa; Stauber, Rudolf E

    2011-09-01

    Toxins accumulating in liver failure split into water solved (e.g. ammonia) and albumin bound substances (e.g. bilirubin). Because the latter cannot be removed by conventional haemodialysis, special liver support systems have been developed. The majority of data concerning elimination efficiency exist for the cell-free devices Molecular Adsorbent Recirculating System (MARS) and Prometheus, as they have been commercially available in Europe since many years. Overall, Prometheus provides higher clearances for most liver toxins, especially if they are tightly albumin bound. However, for bile acids and cytokines no such differences could be found. Single pass albumin dialysis (SPAD) can be assumed to be equally effective as MARS. None of the bioartificial liver support systems being developed is on the market today and published clearance data are scarce. In general, clearance efficiency for albumin bound substances is relatively low in all systems currently available. Besides optimizing biocompatibility and selectivity, future technologies should also focus on improved detoxification efficiency of liver support devices. © 2011 John Wiley & Sons A/S.

  15. Vector meson production in the final state K K of photon-photon collisions

    Energy Technology Data Exchange (ETDEWEB)

    Althoff, M; Braunschweig, W; Gerhards, R; Kirschfink, J F; Martyn, H U; Rosskamp, P; Wallraff, W; Bock, B; Eisenmann, Y; Fischer, H M

    1986-08-01

    Vector meson production is studied in the reaction ->K K . A clear PHI(1020) signal is seen in the K K mass distribution and a Ksup(*0)(890) signal is visible in the Ksup(+-) sup(-+) one. Both do not seem to be strongly correlated with quasi two body final states. Cross sections for the processes ->K K , ->PHI , ->Ksup(*0)Ksup(+-) sup(-+) and upper limits for the production of duction of PHIrho, PHIPHI and Ksup(*0)Ksup(*0) are given as function of the invariant mass.

  16. Practical models to estimate horizontal irradiance in clear sky conditions: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, German A.; Hernandez, Alejandro L.; Saravia, Luis R. [Department of Physics, School of Exact Sciences, National University of Salta, Bolivia Avenue 5150, 4400 Salta Capital (Argentina); INENCO (Institute of Non Conventional Energy Research), Bolivia Avenue 5150, 4400 Salta Capital (Argentina)

    2010-11-15

    The Argentinean Northwest (ANW) is a high altitude region located alongside Los Andes Mountains. The ANW is also one of the most insolated regions in the world due to its altitude and particular climate. However, the characterization of the solar resource in the region is incomplete as there are no stations to measure solar radiation continuously and methodically. With irradiance data recently having been measured at three sites in the Salta Province, a study was carried out that resulted in a practical model to quickly and efficiently estimate the horizontal irradiance in high altitude sites in clear sky conditions. This model uses the altitude above sea level (A) as a variable and generates a representative clearness index as a result (k{sub t-R}) that is calculated for each site studied. This index k{sub t-R} is then used with the relative optical air mass and the extraterrestrial irradiance to estimate the instantaneous clearness index (k{sub t}). Subsequently, the index k{sub t-R} is corrected by introducing the atmospheric pressure in the definition of relative optical air mass proposed by Kasten. The results are satisfactory as errors in the irradiance estimations with respect to measured values do not exceed 5% for pressure corrected air masses AM{sub c} < 2. This model will be used in a feasibility study to locate sites for the installation of solar thermal power plants in the ANW. A prototype of a CLFR solar power plant is being built in the INENCO Campus, at the National University of Salta. (author)

  17. Evaluation of optimum inclusion levels of Biostrong ® 510 as ...

    African Journals Online (AJOL)

    Biostrong® 510 was included at 0g, 15g, 17.5g and 20g/100 Kg diet for T1-T4 respectively while T5 and T6 had Oxytetracyclineand water-grade Neocyril plus respectively. Data was collected ongrowth performance indices, haematological parameters, liver function indices, ileum and ceacum microbial contents, tibia bone ...

  18. An example of a component replacement when applying ASME N509 and ASME N510 to older ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Arndt, T.E. [Westinghouse Hanford Company, Richland, WA (United States)

    1995-02-01

    This paper presents an example of a component replacement (electric heater) when installed in an older ventilation system that was constructed before the issuance of ASME N509{sup 1} and N510{sup 2}. Many of the existing ventilation systems at the Hanford Site were designed, fabricated, and installed before the issuance of ASME N509{sup 1} and N510{sup 2}. Requiring the application of these codes to existing ventilation systems presents challenges to the engineer when design changes are needed. Although it may seem that the application of ASME N509{sup 1} or N510{sup 2} may be a hindrance at times, this does not need to occur. Proper preparation at the start of project or design modifications can minimize frustration to the engineer when it is judged that portions of ASME N509{sup 1} and N510{sup 2} do not apply in a particular application.

  19. 31 CFR 593.510 - Transactions related to the importation of any round log or timber product originating in Liberia...

    Science.gov (United States)

    2010-07-01

    ... importation of any round log or timber product originating in Liberia authorized. 593.510 Section 593.510... importation of any round log or timber product originating in Liberia authorized. Except as otherwise... into the United States of any round log or timber product originating in Liberia are authorized. ...

  20. 33 CFR 148.510 - What happens when a petition for exemption involves the interests of an adjacent coastal State?

    Science.gov (United States)

    2010-07-01

    ... exemption involves the interests of an adjacent coastal State? 148.510 Section 148.510 Navigation and... petition for exemption involves the interests of an adjacent coastal State? If the petition for exemption concerns an adjacent coastal State, the Commandant (CG-5) forwards the petition to the Governor of the...

  1. Are wearable devices ready for HTTPS? Measuring the cost of secure communication protocols on wearable devices

    OpenAIRE

    Kolamunna, Harini; Chauhan, Jagmohan; Hu, Yining; Thilakarathna, Kanchana; Perino, Diego; Makaroff, Dwight; Seneviratne, Aruna

    2016-01-01

    The majority of available wearable devices require communication with Internet servers for data analysis and storage, and rely on a paired smartphone to enable secure communication. However, wearable devices are mostly equipped with WiFi network interfaces, enabling direct communication with the Internet. Secure communication protocols should then run on these wearables itself, yet it is not clear if they can be efficiently supported. In this paper, we show that wearable devices are ready for...

  2. NaK handling and removal

    International Nuclear Information System (INIS)

    Desreumaux, J.; Rodriguez, G.; Guigon, A.; Verdelli, J.; Thomine, G.

    1997-01-01

    Sodium-potassium alloy is used in specific application in French Fast Breeder Reactors as: cold traps, NaK bubbler for argon purification, valves and also in experimental irradiation devices. lt has been preferred to sodium because it is liquid from + 7 deg. C for the most common peritectic alloy. After its use, NaK is considered as a hazardous waste (nuclear or not) due to its high reactivity with air and water. The most important risk remains in handling NaK systems which have not been operated for some time. The NaK will be covered with a crust of the superoxide K02 which is a strong oxidising agent. Thermodynamically, K02 will react with most organic material or metallic dust or swarfs and can also react with additional NaK to give sufficient heat to boil part of the NaK, resulting in a sudden increase in pressure and small explosions. We describe the formation given to experimenters in our Sodium School and the CEA's experience in treating specific devices for transportation, decanting of tanks, tank opening and NaK removal. (author)

  3. SoK: Privacy on Mobile Devices – It’s Complicated

    Directory of Open Access Journals (Sweden)

    Spensky Chad

    2016-07-01

    Full Text Available Modern mobile devices place a wide variety of sensors and services within the personal space of their users. As a result, these devices are capable of transparently monitoring many sensitive aspects of these users’ lives (e.g., location, health, or correspondences. Users typically trade access to this data for convenient applications and features, in many cases without a full appreciation of the nature and extent of the information that they are exposing to a variety of third parties. Nevertheless, studies show that users remain concerned about their privacy and vendors have similarly been increasing their utilization of privacy-preserving technologies in these devices. Still, despite significant efforts, these technologies continue to fail in fundamental ways, leaving users’ private data exposed.

  4. 29 CFR 510.10 - Table of wage rates and effective dates.

    Science.gov (United States)

    2010-07-01

    ... REGULATIONS IMPLEMENTATION OF THE MINIMUM WAGE PROVISIONS OF THE 1989 AMENDMENTS TO THE FAIR LABOR STANDARDS ACT IN PUERTO RICO Schedule of Minimum Wage Rates Applicable in Puerto Rico § 510.10 Table of wage rates and effective dates. (a) The following table provides effective dates of minimum wage increases...

  5. Characteristics of the process K+p→K+anti ppp at 12 GeV/c

    International Nuclear Information System (INIS)

    Armstrong, T.A.; Frame, D.; Hughes, I.S.; Kumar, B.R.; Lewis, G.M.; Macallister, J.B.; Stewart, D.T.; Turnbull, R.M.

    1979-01-01

    Data are presented on the reaction K + p→K + anti ppp at 12 GeV/c from an experiment using the OMEGA spectrometer at CERN. A clear Λ(1520) signal is observed in the process K + p→anti Λ(1520)pp and angular distributions and correlations are presented for this process. The angular distributions for the reaction in which anti Λ(1520) is not produced show an appreciable backward K + peak. (Auth.)

  6. Efficiency optimization of green phosphorescent organic light-emitting device

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jung Soo; Jeon, Woo Sik; Yu, Jae Hyung [Department of Information Display, Kyung Hee University, Dongdaemoon-gu, Seoul 130-701 (Korea, Republic of); Pode, Ramchandra, E-mail: rbpode@khu.ac.k [Department of Physics, Kyung Hee University, Dongdaemoon-gu, Seoul 130-701 (Korea, Republic of); Kwon, Jang Hyuk, E-mail: jhkwon@khu.ac.k [Department of Information Display, Kyung Hee University, Dongdaemoon-gu, Seoul 130-701 (Korea, Republic of)

    2011-03-01

    Using a narrow band gap host of bis[2-(2-hydroxyphenyl)-pyridine]beryllium (Bepp{sub 2}) and green phosphorescent Ir(ppy){sub 3} [fac-tris(2-phenylpyridine) iridium III] guest concentration as low as 2%, high efficiency phosphorescent organic light-emitting diode (PHOLED) is realized. Current and power efficiencies of 62.5 cd/A (max.), 51.0 lm/W (max.), and external quantum efficiency (max.) of 19.8% are reported in this green PHOLED. A low current efficiency roll-off value of 10% over the brightness of 10,000 cd/m{sup 2} is noticed in this Bepp{sub 2} single host device. Such a high efficiency is obtained by the optimization of the doping concentration with the knowledge of the hole trapping and the emission zone situations in this host-guest system. It is suggested that the reported device performance is suitable for applications in high brightness displays and lighting.

  7. Modeling and Simulation for an 8 kW Three-Phase Grid-Connected Photo-Voltaic Power System

    OpenAIRE

    Cen Zhaohui

    2017-01-01

    Gird-connected Photo-Voltaic (PV) systems rated as 5-10 kW level have advantages of scalability and energy-saving, so they are very typical for small-scale household solar applications. In this paper, an 8 kW three-phase grid-connected PV system model is proposed and studied. In this high-fidelity model, some basic PV system components such as solar panels, DC-DC converters, DC-AC inverters and three-phase utility grids are mathematically modelled and organized as a complete simulation model....

  8. A quick guide to API 510 certified pressure vessel inspector syllabus example questions and worked answers

    CERN Document Server

    Matthews, Clifford

    2010-01-01

    The API Individual Certification Programs (ICPs) are well established worldwide in the oil, gas, and petroleum industries. This Quick Guide is unique in providing simple, accessible and well-structured guidance for anyone studying the API 510 Certified Pressure Vessel Inspector syllabus by summarizing and helping them through the syllabus and providing multiple example questions and worked answers.Technical standards are referenced from the API 'body of knowledge' for the examination, i.e. API 510 Pressure vessel inspection, alteration, rerating; API 572 Pressure vessel inspection; API

  9. Digital device for synchronous storage

    International Nuclear Information System (INIS)

    Kobzar', Yu.M.; Kovtun, V.G.; Pashechko, N.I.

    1991-01-01

    Synchronous storage digital device for IR electron-photon emission spectrometer operating with analogue-to-digital converter F4223 or monocrystal converter K572PV1 is described. The device accomplished deduction of noise-background in each storage cycle. Summation and deduction operational time equals 90 ns, device output code discharge - 20, number of storages -2 23

  10. Development of ClearPEM-Sonic, a multimodal mammography system for PET and Ultrasound

    Science.gov (United States)

    Cucciati, G.; Auffray, E.; Bugalho, R.; Cao, L.; Di Vara, N.; Farina, F.; Felix, N.; Frisch, B.; Ghezzi, A.; Juhan, V.; Jun, D.; Lasaygues, P.; Lecoq, P.; Mensah, S.; Mundler, O.; Neves, J.; Paganoni, M.; Peter, J.; Pizzichemi, M.; Siles, P.; Silva, J. C.; Silva, R.; Tavernier, S.; Tessonnier, L.; Varela, J.

    2014-03-01

    ClearPEM-Sonic is an innovative imaging device specifically developed for breast cancer. The possibility to work in PEM-Ultrasound multimodality allows to obtain metabolic and morphological information increasing the specificity of the exam. The ClearPEM detector is developed to maximize the sensitivity and the spatial resolution as compared to Whole-Body PET scanners. It is coupled with a 3D ultrasound system, the SuperSonic Imagine Aixplorer that improves the specificity of the exam by providing a tissue elasticity map. This work describes the ClearPEM-Sonic project focusing on the technological developments it has required, the technical merits (and limits) and the first multimodal images acquired on a dedicated phantom. It finally presents selected clinical case studies that confirm the value of PEM information.

  11. Development of ClearPEM-Sonic, a multimodal mammography system for PET and Ultrasound

    International Nuclear Information System (INIS)

    Cucciati, G; Vara, N Di; Ghezzi, A; Paganoni, M; Pizzichemi, M; Auffray, E; Frisch, B; Lecoq, P; Bugalho, R; Neves, J; Cao, L; Peter, J; Farina, F; Felix, N; Juhan, V; Mundler, O; Siles, P; Jun, D; Lasaygues, P; Mensah, S

    2014-01-01

    ClearPEM-Sonic is an innovative imaging device specifically developed for breast cancer. The possibility to work in PEM-Ultrasound multimodality allows to obtain metabolic and morphological information increasing the specificity of the exam. The ClearPEM detector is developed to maximize the sensitivity and the spatial resolution as compared to Whole-Body PET scanners. It is coupled with a 3D ultrasound system, the SuperSonic Imagine Aixplorer that improves the specificity of the exam by providing a tissue elasticity map. This work describes the ClearPEM-Sonic project focusing on the technological developments it has required, the technical merits (and limits) and the first multimodal images acquired on a dedicated phantom. It finally presents selected clinical case studies that confirm the value of PEM information

  12. Clear retainer

    Directory of Open Access Journals (Sweden)

    Priyakorn Chaimongkol

    2017-01-01

    Full Text Available A clear retainer is a removable retainer that is popular in the present day. Compared with conventional fixed and removable orthodontic retainers, it is a more esthetic, comfortable, and inexpensive appliance. Although several studies have been published about clear retainers, it could be difficult to interpret the results because of the variety of study designs, sample sizes, and research methods. This article is intended to compile the content from previous studies and discuss advantages, disadvantages, fabrication, insertion, and adjustment. Moreover, the effectiveness in maintaining dental position, occlusion, retention protocols, thickness, and survival rate of clear retainers is discussed.

  13. The PTPN11 loss-of-function mutation Q510E-Shp2 causes hypertrophic cardiomyopathy by dysregulating mTOR signaling.

    Science.gov (United States)

    Schramm, Christine; Fine, Deborah M; Edwards, Michelle A; Reeb, Ashley N; Krenz, Maike

    2012-01-01

    The identification of mutations in PTPN11 (encoding the protein tyrosine phosphatase Shp2) in families with congenital heart disease has facilitated mechanistic studies of various cardiovascular defects. However, the roles of normal and mutant Shp2 in the developing heart are still poorly understood. Furthermore, it remains unclear how Shp2 loss-of-function (LOF) mutations cause LEOPARD Syndrome (also termed Noonan Syndrome with multiple lentigines), which is characterized by congenital heart defects such as pulmonary valve stenosis and hypertrophic cardiomyopathy (HCM). In normal hearts, Shp2 controls cardiomyocyte size by regulating signaling through protein kinase B (Akt) and mammalian target of rapamycin (mTOR). We hypothesized that Shp2 LOF mutations dysregulate this pathway, resulting in HCM. For our studies, we chose the Shp2 mutation Q510E, a dominant-negative LOF mutation associated with severe early onset HCM. Newborn mice with cardiomyocyte-specific overexpression of Q510E-Shp2 starting before birth displayed increased cardiomyocyte sizes, heart-to-body weight ratios, interventricular septum thickness, and cardiomyocyte disarray. In 3-mo-old hearts, interstitial fibrosis was detected. Echocardiographically, ventricular walls were thickened and contractile function was depressed. In ventricular tissue samples, signaling through Akt/mTOR was hyperactivated, indicating that the presence of Q510E-Shp2 led to upregulation of this pathway. Importantly, rapamycin treatment started shortly after birth rescued the Q510E-Shp2-induced phenotype in vivo. If rapamycin was started at 6 wk of age, HCM was also ameliorated. We also generated a second mouse model in which cardiomyocyte-specific Q510E-Shp2 overexpression started after birth. In contrast to the first model, these mice did not develop HCM. In summary, our studies establish a role for mTOR signaling in HCM caused by Q510E-Shp2. Q510E-Shp2 overexpression in the cardiomyocyte population alone was sufficient to

  14. Comparison of a state of the art Si IGBT and next generation fast switching devices in a 4 kW boost converter

    DEFF Research Database (Denmark)

    Anthon, Alexander; Zhang, Zhe; Andersen, Michael A. E.

    2015-01-01

    This paper gives a comprehensive comparison of two promising silicon carbide (SiC) switching devices, i.e. normally-off SiC MOSFET and a normally-on SiC JFET, as alternatives to a conventional state of the art Si IGBT. The comparison uses datasheet information to determine conduction losses, swit...... losses. This reduction in semiconductor losses can increase overall converter efficiencies up to 0.4% at 20kHz or enable high frequency operation up to 100 kHz which then reduces the size and weight of the inductor by more than 75% while still achieving efficiencies over 98.3 %....

  15. Warm Pressurant Gas Effects on the Static Bubble Point Pressure for Cryogenic LADs

    Science.gov (United States)

    Hartwig, Jason W.; McQuillen, John; Chato, Daniel J.

    2014-01-01

    This paper presents experimental results for the liquid hydrogen and nitrogen bubble point tests using warm pressurant gases conducted at the NASA Glenn Research Center. The purpose of the test series was to determine the effect of elevating the temperature of the pressurant gas on the performance of a liquid acquisition device (LAD). Three fine mesh screen samples (325x2300, 450x2750, 510x3600) were tested in liquid hydrogen and liquid nitrogen using cold and warm non-condensable (gaseous helium) and condensable (gaseous hydrogen or nitrogen) pressurization schemes. Gases were conditioned from 0K - 90K above the liquid temperature. Results clearly indicate degradation in bubble point pressure using warm gas, with a greater reduction in performance using condensable over non-condensable pressurization. Degradation in the bubble point pressure is inversely proportional to screen porosity, as the coarsest mesh demonstrated the highest degradation. Results here have implication on both pressurization and LAD system design for all future cryogenic propulsion systems. A detailed review of historical heated gas tests is also presented for comparison to current results.

  16. Torsion based universal MEMS logic device

    KAUST Repository

    Ilyas, Saad; Carreno, Armando Arpys Arevalo; Bayes, Ernesto; Foulds, Ian G.; Younis, Mohammad I.

    2015-01-01

    In this work we demonstrate torsion based complementary MEMS logic device, which is capable, of performing INVERTER, AND, NAND, NOR, and OR gates using one physical structure within an operating range of 0-10 volts. It can also perform XOR and XNOR with one access inverter using the same structure with different electrical interconnects. The paper presents modeling, fabrication and experimental calculations of various performance features of the device including lifetime, power consumption and resonance frequency. The fabricated device is 535 μm by 150 μm with a gap of 1.92 μm and a resonant frequency of 6.51 kHz. The device is capable of performing the switching operation with a frequency of 1 kHz.

  17. Torsion based universal MEMS logic device

    KAUST Repository

    Ilyas, Saad

    2015-10-28

    In this work we demonstrate torsion based complementary MEMS logic device, which is capable, of performing INVERTER, AND, NAND, NOR, and OR gates using one physical structure within an operating range of 0-10 volts. It can also perform XOR and XNOR with one access inverter using the same structure with different electrical interconnects. The paper presents modeling, fabrication and experimental calculations of various performance features of the device including lifetime, power consumption and resonance frequency. The fabricated device is 535 μm by 150 μm with a gap of 1.92 μm and a resonant frequency of 6.51 kHz. The device is capable of performing the switching operation with a frequency of 1 kHz.

  18. Construction and characterization of a plasma focus device and diagnostic test ion

    International Nuclear Information System (INIS)

    Morales Arango, Diana Marsela

    2013-01-01

    In this work we designed and built a Plasma Focus device 2kJ power in order to extend the energy range of devices designed in DPTN CCHEN and study the scaling laws type Plasma Focus Device. The operating parameters of this device are: T/ 4 =907ns, C = 8000nF, L = 42nH, E = 2kJ, lo = 276kA. In such a way to optimize the device tests were performed with various electrode configurations, insulator length, to determine the conditions under which it operates in Plasma Focus mode. Subsequent to the construction tests were performed on devices PF-400J (T /4 = 300ns, C = 880nF, L = 38nH, E = 400J, lo = 168kA) y PF-2kJ (device between the hundreds of joules and kilojoules of energy) diagnostic charged particle emission used the Faraday Cup consisting of a biased graphite collector. For a series of shots on the PF-400J and PF-2kJ operated at 27kV and 20kV respectively kinetic energy distribution of proton between 60keV-150keV were found, deuterons between 60KeV-300KeV. With the idea of optimizing the results in future diagnostic type spectrometer Thompson, spectroscopy and diffraction networks in gas mixture will be implemented

  19. Vector meson production in the final state K+K-π+π- photon-photon collisions

    International Nuclear Information System (INIS)

    ALthoff, M.; Braunschweig, W.; Gerhards, R.; Kirschfink, J.F.; Martyn, H.U.; Rosskamp, P.; Wallraff, W.; Bowler, M.G.; Bull, P.; Cashmore, R.J.; Dauncey, P.; Devenish, R.; Heath, G.; Mellor, D.J.; Ratoff, P.; Baranko, G.; Caldwell, A.; Cherney, M.; Izen, J.M.; Ritz, S.; Strom, D.; Takashima, M.; Wicklund, E.; Wu Saulan; Zobernig, G.; Bernardi, E.; Eisenberg, Y.; Eskresy, A.; Gather, K.; Hultschig, H.; Joos, P.; Klima, B.; Kowalski, H.; Ladage, A.; Loehr, B.; Maettig, P.; Notz, D.; Revel, D.; Ronat, E.; Trines, D.; Tymieniecka, R.; Walcak, R.; Wolf, G.; Zeuner, W.S.

    1986-03-01

    Vector meson production is studied in the reaction γγ -> K + K - π + π - . A clear PHI(1020) signal is seen in the K + K - mass distribution and a Ksup(*0)(890) signal is visible in the Ksup(+-)πsup(-+) one. Both do not seem to be strongly correlated with quasi two body final states. Cross sections for the processes γγ -> K + K - π + π - , γγ -> PHIπ + π - , γγ -> Ksup(*0)Ksup(+-)πsup(-+) and upper limits for the production of PHIrho, PHIPHI and Ksup(*0)Ksup(*0) are given as function of the invariant γγ mass. (orig.)

  20. 40 CFR 174.510 - Bacillus thuringiensis Cry1Ac protein in all plants; exemption from the requirement of a tolerance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Bacillus thuringiensis Cry1Ac protein in all plants; exemption from the requirement of a tolerance. 174.510 Section 174.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PROCEDURES AND REQUIREMENTS FOR PLANT-INCORPORATED PROTECTANTS Tolerances...

  1. ORKA: Measurement of the $K^ \\to \\pi^+ \

    Energy Technology Data Exchange (ETDEWEB)

    Comfort, Joseph; /Arizona State U.; Bryman, Douglas; Doria, Luca; Numao, Toshio; Sher, Aleksey; Vavilov, Dimitry; /British Columbia U. /TRIUMF; Jaffe, David; Kettell, Steve; Littenberg, Laurence; Worcester, Elizabeth; /Brookhaven; Bellantoni, Leo; /Fermilab /Illinois U., Urbana /INFN, Naples /INFN, Pisa /Moscow, INR /Dubna, JINR /Northern British Columbia U. / /Mexico U. /San Luis Potosi U.

    2011-11-28

    A high precision measurement of the ultra-rare K{sup +} {yields} {pi}{sup +} {nu}{bar {nu}} decay at Fermilab would be one of the most incisive probes of quark flavor physics this decade. Its dramatic reach for uncovering new physics is due to several important factors: (1) The branching ratio is sensitive to most new physics models which extend the Standard Model to solve its considerable problems. (2) The Standard Model predictions for the K{sup +} {yields} {pi}{sup +} {nu}{bar {nu}} and K{sub L}{sup 0} {yields} {pi}{sup 0} {nu}{bar {nu}} branching fractions are broadly recognized to be theoretically robust at the 5-10% level. Only a precious few accessible loop-dominated quark processes can be predicted with this level of certainty. (3) The K{sup +} {yields} {pi}{sup +} {nu}{bar {nu}} branching fraction is highly suppressed in the Standard Model to the level < 10{sup -10} (<1 part in 10 billion). This suppression allows physics beyond the Standard Model to contribute dramatically to the branching fraction with enhancements of up to factors of 5 above the Standard Model level. (4) The certainty with which the Standard Model contribution to K{sup +} {yields} {pi}{sup +} {nu}{bar {nu}} can be predicted will permit a 5{sigma} discovery potential for new physics even for enhancements of the branching fraction as small as 35%. This sensitivity is unique in quark flavor physics and allows probing of essentially all models of new physics that couple to quarks within the reach of the LHC. Furthermore, a high precision measurement of K{sup +} {yields} {pi}{sup +} {nu}{bar {nu}} is sensitive to many models of new physics with mass scales well beyond the direct reach of the LHC. The experimental challenge of suppressing backgrounds to enable measurement of K{sup +} {yields} {pi}{sup +} {nu}{bar {nu}} at the 1 in 10-billion Standard Model rate has been met successfully. Several events of K{sup +} {yields} {pi}{sup +} {nu}{bar {nu}} decay have been clearly observed at BNL by

  2. 21 CFR 890.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... hepatitis, tuberculosis, or myocardial infarction or to monitor therapy; (4) For assessing the risk of... ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES...

  3. Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya

    2018-01-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.

  4. Channel mobility degradation and charge trapping in high-k/metal gate NMOSFETs

    International Nuclear Information System (INIS)

    Mathew, Shajan; Bera, L.K.; Balasubramanian, N.; Joo, M.S.; Cho, B.J.

    2004-01-01

    NMOSFETs with Metalo-Organic Chemical Vapor Deposited (MOCVD) HfAlO gate dielectric and TiN metal gate have been fabricated. Channel electron mobility was measured using the split-CV method and compared with SiO 2 devices. All high-k devices showed lower mobility compared with SiO 2 reference devices. High-k MOSFETs exhibited significant charge trapping and threshold instability. Threshold voltage recovery with time was studied on devices with oxide/nitride interfacial layer between high-k film and silicon substrate

  5. Coating of Titanium Nitride on Stainless Steel Targets by a 4 kJ Plasma Focus Device

    Science.gov (United States)

    Omrani, M.; Habibi, M.; Amrollahi, R.

    2012-08-01

    Titanium nitride thin films were deposited on stainless steel (SS316L) targets by using a 4 kJ plasma focus device. The corresponding energy flux delivered to SS316L surface is estimated to be 2.69 × 1013 kev cm-3 ns-1. X-ray diffraction analysis reveals the formation of a nanocrystalline titanium nitride coating on the surface of targets. Thickness of the elements found on the surface of treated samples which are obtained by Rutherford backscattering spectrometry analysis (RBS) were (×1015 at/cm2) .45% Ti, 50% N and 5% Fe. Scanning electron microscopy was used to indicate changes in surface morphology. Existence of grains in different size confirms the formation of TiN crystals on the surface of targets.

  6. The Thrombospondin-1 Mimetic ABT-510 Increases the Uptake and Effectiveness of Cisplatin and Paclitaxel in a Mouse Model of Epithelial Ovarian Cancer

    Directory of Open Access Journals (Sweden)

    Nicole E. Campbell

    2010-03-01

    Full Text Available Epithelial ovarian cancer (EOC comprises approximately 90% of ovarian cancers and arises from the surface epithelium. Typical treatment of EOC involves cytoreductive surgery combined with chemotherapy. More recent therapies have targeted the tumor vasculature using antiangiogenic compounds such as thrombospondin-1 (TSP-1. TSP-1 mimetic peptides such as ABT-510 have been created and have been in various clinical trials. We have previously shown that ABT-510 reduces abnormal vasculature associated with tumor tissue and increases the presence of mature blood vessels. It has been hypothesized that treatment with antiangiogenic compounds would allow increased delivery of cytotoxic agents and enhance treatment. In this study, we evaluated the potential role of ABT-510 and various chemotherapeutics (cisplatin and paclitaxel on tumor progression, angiogenesis, and the benefits of combinational treatments on tissue uptake and perfusion using an orthotopic syngeneic mouse model of EOC. Animals were treated with ABT-510 (100 mg/kg per day alone or in combination with cisplatin (2 mg/kg per 3 days or paclitaxel (10 mg/kg per 2 days at 60 days after tumor induction. Radiolabeled and fluorescently labeled paclitaxel demonstrated a significant increase in tumor uptake after ABT-510 treatment. Combined treatment with ABT-510 and cisplatin or paclitaxel resulted in a significant increase in tumor cell and tumor endothelial cell apoptosis and a resultant decrease in ovarian tumor size. Combined treatment also regressed secondary lesions and eliminated the presence of abdominal ascites. The results from this study show that through vessel normalization, ABT-510 increases uptake of chemotherapy drugs and can induce regression of advanced ovarian cancer.

  7. 40 CFR 1048.510 - What transient duty cycles apply for laboratory testing?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What transient duty cycles apply for... Procedures § 1048.510 What transient duty cycles apply for laboratory testing? (a) Starting with the 2007 model year, measure emissions by testing the engine on a dynamometer with the duty cycle described in...

  8. The Psychometrics of the Mini-K.

    Science.gov (United States)

    Richardson, George B; Chen, Ching-Chen; Dai, Chia-Liang; Brubaker, Michael D; Nedelec, Joseph L

    2017-01-01

    Many published studies have employed the Mini-K to measure a single fast-slow life history dimension. However, the internal structure of the Mini-K has not been determined and it is not clear that a single higher order K-factor fits the data. It is also not clear that the Mini-K is measurement invariant across groups such as the sexes. To establish the construct validity of K as well as the broader usefulness of applying life history theory to humans, it is crucial that these psychometric issues are addressed as a part of measure validation efforts. Here we report on three studies that used latent variable modeling and data drawn from two college student samples ( ns = 361 and 300) to elucidate the psychometrics of the Mini-K. We found that (a) the Mini-K had a six dimensional first-order structure, (b) the K-factor provided a parsimonious explanation of the associations among the lower order factors at no significant cost to fit, (c) the Mini-K measured the same K-factor across the sexes, (d) K-factor means did not have the same meaning across the sexes and thus the first-order factors should be used in studies of mean sex differences, and finally, (e) the K-factor was only associated with environment and aspects of mating competition in females. Implications and future directions for life history research are discussed.

  9. 19 CFR 10.510 - Filing of claim for preferential tariff treatment upon importation.

    Science.gov (United States)

    2010-04-01

    ... RATE, ETC. United States-Singapore Free Trade Agreement Import Requirements § 10.510 Filing of claim... method specified for equivalent reporting via an authorized electronic data interchange system. For all... classified, or by the method specified for equivalent reporting via an authorized electronic data interchange...

  10. X-ray spot film device

    International Nuclear Information System (INIS)

    1981-01-01

    Improvements are described in an X-ray spot film device which is used in conjunction with an X-ray table to make a selected number of radiographic exposures on a single film and to perform fluoroscopic examinations. To date, the spot film devices consist of two X-ray field defining masks, one of which is moved manually. The present device is more convenient to use and speeds up the procedure. (U.K.)

  11. 19 CFR 351.510 - Indirect taxes and import charges (other than export programs).

    Science.gov (United States)

    2010-04-01

    ... OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Identification and Measurement of Countervailable Subsidies § 351.510 Indirect taxes and import charges (other than export programs). (a) Benefit—(1... the full or partial exemption or remission of an indirect tax or an import charge, a benefit exists to...

  12. K.S. Micro‑Implant Placement Guide

    African Journals Online (AJOL)

    after being injured by temporary orthodontic anchorage devices,[3] ... and does not disturb the existing appliance system, clearly ... The wire guide is fabricated using round 0.018 or 0.020 ... their clinical efficiency in anchorage control.

  13. Cellulose Degradation by Cellulose-Clearing and Non-Cellulose-Clearing Brown-Rot Fungi

    OpenAIRE

    Highley, Terry L.

    1980-01-01

    Cellulose degradation by four cellulose-clearing brown-rot fungi in the Coniophoraceae—Coniophora prasinoides, C. puteana, Leucogyrophana arizonica, and L. olivascens—is compared with that of a non-cellulose-clearing brown-rot fungus, Poria placenta. The cellulose- and the non-cellulose-clearing brown-rot fungi apparently employ similar mechanisms to depolymerize cellulose; most likely a nonenzymatic mechanism is involved.

  14. DNA Physical Mapping via the Controlled Translocation of Single Molecules through a 5-10nm Silicon Nitride Nanopore

    Science.gov (United States)

    Stein, Derek; Reisner, Walter; Jiang, Zhijun; Hagerty, Nick; Wood, Charles; Chan, Jason

    2009-03-01

    The ability to map the binding position of sequence-specific markers, including transcription-factors, protein-nucleic acids (PNAs) or deactivated restriction enzymes, along a single DNA molecule in a nanofluidic device would be of key importance for the life-sciences. Such markers could give an indication of the active genes at particular stage in a cell's transcriptional cycle, pinpoint the location of mutations or even provide a DNA barcode that could aid in genomics applications. We have developed a setup consisting of a 5-10 nm nanopore in a 20nm thick silicon nitride film coupled to an optical tweezer setup. The translocation of DNA across the nanopore can be detected via blockades in the electrical current through the pore. By anchoring one end of the translocating DNA to an optically trapped microsphere, we hope to stretch out the molecule in the nanopore and control the translocation speed, enabling us to slowly scan across the genome and detect changes in the baseline current due to the presence of bound markers.

  15. Does One Need a 4.5 K Screen in Cryostats of Superconducting Accelerator Devices Operating in Superfluid Helium? Lessons from the LHC

    CERN Document Server

    Lebrun, Ph; Tavian, L

    2014-01-01

    Superfluid helium is increasingly used as a coolant for superconducting devices in particle accelerators: the lower temperature enhances the performance of superconductors in high-field magnets and reduces BCS losses in RF acceleration cavities, while the excellent transport properties of superfluid helium can be put to work in efficient distributed cooling systems. The thermodynamic penalty of operating at lower temperature however requires careful management of the heat loads, achieved inter alia through proper design and construction of the cryostats. A recurrent question appears to be that of the need and practical feasibility of an additional screen cooled by normal helium at around 4.5 K surrounding the cold mass at about 2 K, in such cryostats equipped with a standard 80 K screen. We introduce the issue in terms of first principles applied to the configuration of the cryostats, discuss technical constraints and economical limitations, and illustrate the argumentation with examples taken from large proj...

  16. Nitride semiconductor devices fundamentals and applications

    CERN Document Server

    Morkoç, Hadis

    2013-01-01

    This book gives a clear presentation of the necessary basics of semiconductor and device physics and engineering. It introduces readers to fundamental issues that will enable them to follow the latest technological research. It also covers important applications, including LED and lighting, semiconductor lasers, high power switching devices, and detectors. This balanced and up-to-date treatment makes the text an essential educational tool for both advanced students and professionals in the electronics industry.

  17. Analysis of K/sup -/K/sup +/ and. pi. /sup -/. pi. /sup +/ final states in 13 GeV K/sup -/p interactions. [Differential cross sections, density matrix elements, branching ratio

    Energy Technology Data Exchange (ETDEWEB)

    Brandenburg, G W; Carnegie, R K; Cashmore, R J; Davier, M; Lasinski, T A; Leith, D W.G.S.; Mathews, J A.J.; Walden, P; Williams, S H [Stanford Linear Accelerator Center, Calif. (USA)

    1976-03-01

    The differential cross sections and density matrix elements for the phi and rho/sup 0/ mesons have been measured in the reactions K/sup -/p..-->..K/sup -/K/sup +/(..lambda..,..sigma../sup 0/) and K/sup -/p..--> pi../sup -/..pi../sup +/(..lambda..,..sigma../sup 0/) at 13 GeV using a wire chamber spectrometer. The analysis shows that while the vector meson production is dominated by the natural parity exchange amplitude, some unnatural parity exchange is also required. Furthermore the phi and rho natural exchange cross sections are identical in shape and have the 2:1 relative strength expected in the quark model with K* and K** exchange degeneracy. The analysis of the clear peak-dip rho/sup 0/-..omega.. interference pattern observed in the ..pi../sup -/..pi../sup +/ data indicates that the ..omega.. production is in phase with the rho and of similar magnitude. Both the S* and f' meson are clearly observed in this experiment. The S* data are found to be consistent with S* parameters deduced from ..pi pi.. scattering analyses. The f' density matrix elements and a new limit on the f'..--> pi../sup -/..pi../sup +/ branching ratio are presented.

  18. Workers' exposure to electric fields during the task 'maintenance of an operating device of circuit breaker from a service platform' at 110-kV substations.

    Science.gov (United States)

    Korpinen, Leena; Pääkkönen, Rauno

    2018-02-26

    The objective of the study was to investigate occupational exposure to electric fields during the task 'maintenance of an operating device of circuit breaker from a service platform' at 110-kV substations. The aim was also to compare the results to Directive 2013/35/EU. At 16 substations, 255 electric field measurements were performed. The highest mean value of the electric fields was 9.6 kV⋅m -1 . At 63% of substations the maximum values were over 10.0 kV⋅m -1 , and at 31% of the substations the 75th percentiles were over 10.0 kV⋅m -1 , which is the low action level (AL) according to Directive 2013/35/EU. All measured values were below the high AL (20.0 kV⋅m -1 ). In the future, it is important to take into account that the measurements were only taken at Finnish 110-kV substations; therefore, it is not possible to generalize these results to other countries and different types of substations.

  19. Synthesis of the muscle relaxant [14C]L-637,510

    International Nuclear Information System (INIS)

    O'Connor, S.P.; Ellsworth, R.L.; Gatto, G.

    1991-01-01

    The synthesis of (E)-3-(9-chloro-5,6-dihydro-11H-pyrolo(2,1-b)(3)-benzazepin-11-ylidene)-N,N-dimethyl-1- [3- 14 C]-propanamine (Z)-2-butenedioate(1:1) ([ 14 C]L-637,510), a potential muscle relaxant product for which 14 C-labeling was required for metabolism studies, is described. Introduction of the label in the 3-position of the propanamine side chain was accomplished in eight steps from sodium [ 14 C]cyanide with an overall radiochemical yield of 4.8%. (author)

  20. 17 CFR 249.510 - Form 10-M, consent to service of process by a nonresident general partner of a broker-dealer firm.

    Science.gov (United States)

    2010-04-01

    ..., consent to service of process by a nonresident general partner of a broker-dealer firm. This form shall be... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Form 10-M, consent to service of process by a nonresident general partner of a broker-dealer firm. 249.510 Section 249.510...

  1. 76 FR 47529 - Customer Clearing Documentation and Timing of Acceptance for Clearing; Correction

    Science.gov (United States)

    2011-08-05

    ... COMMODITY FUTURES TRADING COMMISSION 17 CFR Parts 1, 23, and 39 RIN 3038-AD51 Customer Clearing Documentation and Timing of Acceptance for Clearing; Correction AGENCY: Commodity Futures Trading Commission... published in the Federal Register of August 1, 2011, regarding Customer Clearing Documentation and Timing of...

  2. Inter-comparison of different models for estimating clear sky solar global radiation for the Negev region of Israel

    International Nuclear Information System (INIS)

    Ianetz, Amiran; Lyubansky, Vera; Setter, Ilan; Kriheli, Boris; Evseev, Efim G.; Kudish, Avraham I.

    2007-01-01

    Solar global radiation is a function of solar altitude, site altitude, albedo, atmospheric transparency and cloudiness, whereas solar global radiation on a clear day is defined such that it is a function of all the abovementioned parameters except cloudiness. Consequently, analysis of the relative magnitudes of solar global radiation and solar global radiation on a clear day provides a platform for studying the influence of cloudiness on solar global radiation. The Iqbal filter for determining the day type has been utilized to calculate the monthly average clear day solar global radiation at three sites in the Negev region of Israel. An inter-comparison between four models for estimating clear sky solar global radiation at the three sites was made. The relative accuracy of the four models was determined by comparing the monthly average daily clear sky solar global radiation to that determined using the Iqbal filter. The analysis was performed on databases consisting of measurements made during the time interval of January 1991 to December 2004. The monthly average daily clear sky solar global radiation determined by the Berlynd model was found to give the best agreement with that determined using the Iqbal filter. The Berlynd model was then utilized to calculate a daily clear day index, K c , which is defined as the ratio of the daily solar global radiation to the daily clear day solar global radiation. It is suggested that this index be used as an indication of the degree of cloudiness. Linear regression analysis was performed on the individual monthly databases for each site to determine the correlation between the daily clear day index and the daily clearness index, K T

  3. Infrared thermal annealing device

    International Nuclear Information System (INIS)

    Gladys, M.J.; Clarke, I.; O'Connor, D.J.

    2003-01-01

    A device for annealing samples within an ultrahigh vacuum (UHV) scanning tunneling microscopy system was designed, constructed, and tested. The device is based on illuminating the sample with infrared radiation from outside the UHV chamber with a tungsten projector bulb. The apparatus uses an elliptical mirror to focus the beam through a sapphire viewport for low absorption. Experiments were conducted on clean Pd(100) and annealing temperatures in excess of 1000 K were easily reached

  4. 40 CFR 1039.510 - Which duty cycles do I use for transient testing?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Which duty cycles do I use for... ENGINES Test Procedures § 1039.510 Which duty cycles do I use for transient testing? (a) Measure emissions by testing the engine on a dynamometer with one of the following transient duty cycles to determine...

  5. Clearly Transparent Nanopaper from Highly Concentrated Cellulose Nanofiber Dispersion Using Dilution and Sonication

    Directory of Open Access Journals (Sweden)

    Takaaki Kasuga

    2018-02-01

    Full Text Available Nanopaper prepared from holocellulose pulp is one of the best substrates for flexible electronics because of its high thermal resistance and high clear transparency. However, the clearness of nanopaper decreases with increasing concentration of the starting cellulose nanofiber dispersion—with the use of a 2.2 wt % dispersion, for example—resulting in translucent nanopaper with a high haze of 44%. To overcome this problem, we show that the dilution of this high-concentration dispersion with water followed by sonication for 10 s reduces the haze to less than 10% while maintaining the high thermal resistance of the nanopaper. Furthermore, the combination of water dilution and a short sonication treatment improves the clearness of the nanopaper, which would translate into cost savings for the transportation and storage of this highly concentrated cellulose nanofiber dispersion. Finally, we demonstrate the improvement of the electrical conductivity of clear transparent nanopaper prepared from an initially high-concentration dispersion by dropping and heating silver nanowire ink on the nanopaper. These achievements will pave the way toward the realization of the mass production of nanofiber-based flexible devices.

  6. Management of antithrombotic therapy during cardiac implantable device surgery.

    Science.gov (United States)

    AlTurki, Ahmed; Proietti, Riccardo; Birnie, David H; Essebag, Vidal

    2016-06-01

    Anticoagulants are commonly used drugs that are frequently encountered during device placement. Deciding when to halt or continue the use of anticoagulants is a balance between the risks of thromboembolism versus bleeding. Patients taking warfarin with a high risk of thromboembolism should continue to take their warfarin without interruption during device placement while ensuring their international normalized ratio remains below 3. For patients who are taking warfarin and have low risk of thromboembolism, either interrupted or continued warfarin may be used, with no evidence to clearly support either strategy. There is little evidence to support continuing direct acting oral anticoagulants (DOACs) for device implantation. The timing of halting these medications depends largely on renal function. If bleeding occurs, warfarin׳s anticoagulation effect is reversible with vitamin K and activated prothrombin complex concentrate. There are no DOAC reversal agents currently available, but some are under development. Regarding antiplatelet agents, aspirin alone can be safely continued while clopidogrel alone may also be continued, but with a slightly higher bleeding risk. Dual antiplatelet therapy for bare-metal stent/drug-eluting stent implanted within 4 weeks/6 months, respectively, should be continued due to high risk of stent thrombosis; however, if they are implanted after this period, then clopidogrel can be halted 5 days before the procedure and resumed soon after, while aspirin is continued. If the patient is taking both aspirin and warfarin, aspirin should be halted 5 days prior to the procedure, while warfarin is continued.

  7. Characterisation and Control of a Prototype HTS SMES Device

    International Nuclear Information System (INIS)

    Hawley, C J; Cuiuri, D; Cook, C D; Gower, S A; Beales, T P

    2006-01-01

    A 2.79 kJ prototype high transition temperature Superconducting Magnetic Energy Storage (SMES) device has been constructed. The coil for the prototype has been wound using High Temperature Superconducting (HTS) BSCCO-2223 tape. The refrigeration system is a gaseous helium cold head cryocooler used to maintain the SMES coil at a temperature of 30 K, improving the I c characteristic of the coil by a factor of 4.7 compared to that at 77 K. The SMES device is capable of supplying a 3-phase load during power interruptions, and has been constructed during a program to develop a larger 20 kJ system aimed at industrial applications

  8. Effect of vacuum annealing on evaporated pentacene thin films for memory device applications

    International Nuclear Information System (INIS)

    Gayathri, A.G.; Joseph, C.M.

    2016-01-01

    Graphical abstract: Switching of ITO/pentacene/Al thin films for different annealing temperatures. - Highlights: • Memory device performance in pentacene improved considerably with annealing. • ON/OFF ratio of the pentacene device increases due to annealing. • Threshold voltage reduces from 2.55 V to 1.35 V due to annealing. • Structure of pentacene thin films is also dependent on annealing temperature. - Abstract: Thin films of pentacene were deposited thermally onto glass substrates and annealed at 323 K, 373 K, 423 K, 473 K and 523 K in high vacuum. Effect of annealing on the morphological and structural properties of these films was studied. X-ray diffraction patterns confirmed the crystalline nature of the films. Electrical studies for the use as write once read many (WORM) memory devices were done for the vacuum deposited pentacene thin films on indium tin oxide coated glass. Due to annealing, a sharp increase in the ON/OFF ratio of current and a decrease in threshold voltage were observed at around 373 K. This device showed a stable switching with an ON/OFF current ratio as high as 10 9 and a switching threshold voltage of 1.35 V. The performance of the device degraded above 423 K due to the changes in the crystallinity of the film.

  9. Effect of vacuum annealing on evaporated pentacene thin films for memory device applications

    Energy Technology Data Exchange (ETDEWEB)

    Gayathri, A.G., E-mail: gaythri305@yahoo.com; Joseph, C.M., E-mail: cmjoseph@rediffmail.com

    2016-09-15

    Graphical abstract: Switching of ITO/pentacene/Al thin films for different annealing temperatures. - Highlights: • Memory device performance in pentacene improved considerably with annealing. • ON/OFF ratio of the pentacene device increases due to annealing. • Threshold voltage reduces from 2.55 V to 1.35 V due to annealing. • Structure of pentacene thin films is also dependent on annealing temperature. - Abstract: Thin films of pentacene were deposited thermally onto glass substrates and annealed at 323 K, 373 K, 423 K, 473 K and 523 K in high vacuum. Effect of annealing on the morphological and structural properties of these films was studied. X-ray diffraction patterns confirmed the crystalline nature of the films. Electrical studies for the use as write once read many (WORM) memory devices were done for the vacuum deposited pentacene thin films on indium tin oxide coated glass. Due to annealing, a sharp increase in the ON/OFF ratio of current and a decrease in threshold voltage were observed at around 373 K. This device showed a stable switching with an ON/OFF current ratio as high as 10{sup 9} and a switching threshold voltage of 1.35 V. The performance of the device degraded above 423 K due to the changes in the crystallinity of the film.

  10. 24 CFR 598.510 - Nominations by Economic Development Corporations or the District of Columbia.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 3 2010-04-01 2010-04-01 false Nominations by Economic Development... ZONES: ROUND TWO AND THREE DESIGNATIONS Special Rules § 598.510 Nominations by Economic Development Corporations or the District of Columbia. Any urban area nominated by an Economic Development Corporation...

  11. A high-resolution mK-calorimeter applying SQUID-thermometry

    Energy Technology Data Exchange (ETDEWEB)

    Reifenberger, Andreas; Leps, Norman; Fleischmann, Andreas; Pies, Christian; Enss, Christian; Klingeler, Ruediger [Kirchhoff-Institut fuer Physik, Universitaet Heidelberg, INF 227,69120 Heidelberg (Germany)

    2012-07-01

    A new calorimeter for measuring single-crystalline samples of mg-size at ultra-low temperatures is described. Thermometry is done by means of a paramagnetic sensor material (Er-doped Au) in a low magnetic field. A temperature change results in a magnetization change which can be read out as change in magnetic flux by a superconducting quantum interference device (SQUID). This enables measurements in a wide temperature range (theoretically from 1 mK-1 K) with very high sensitivities. The bolometric design exhibits low addenda heat capacity and allows measurements of heat capacities from nJ/K to {mu}J/K by means of a temperature-relaxation method. The performance of the device is compared to a commercially available Quantum Design calorimeter in elsewise unchanged experimental settings in the temperature range from 15 mK to 500 mK.

  12. CLEAR test facility

    CERN Multimedia

    Ordan, Julien Marius

    2017-01-01

    A new user facility for accelerator R&D, the CERN Linear Electron Accelerator for Research (CLEAR), started operation in August 2017. CLEAR evolved from the former CLIC Test Facility 3 (CTF3) used by the Compact Linear Collider (CLIC). The new facility is able to host and test a broad range of ideas in the accelerator field.

  13. The origin and control of the sources of AMR in (Ga,Mn)As devices

    Czech Academy of Sciences Publication Activity Database

    Rushforth, A.W.; Výborný, Karel; King, C.S.; Edmonds, K. W.; Campion, R. P.; Foxon, C. T.; Wunderlich, J.; Irvine, A.C.; Novák, Vít; Olejník, Kamil; Kovalev, A.A.; Sinova, J.; Jungwirth, Tomáš; Gallagher, B. L.

    2009-01-01

    Roč. 321, č. 8 (2009), s. 1001-1008 ISSN 0304-8853 R&D Projects: GA MŠk LC510; GA AV ČR KAN400100652; GA ČR GEFON/06/E002; GA ČR GA202/05/0575; GA ČR GA202/04/1519 EU Projects: European Commission(XE) 015728 - NANOSPIN Institutional research plan: CEZ:AV0Z10100521 Keywords : ferromagnetic semiconductor * anisotropic magnetoresistance Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.204, year: 2009

  14. Incore monitoring device

    International Nuclear Information System (INIS)

    Tai, Ichiro; Shirayama, Shin-pei; Nozaki, Shin-ichi.

    1978-01-01

    Purpose: To provide an incore monitoring device wherein both radiation monitoring and acoustic monitoring are carried out simultaneously by one detector, whereby installation of the device and signal pick-up are facilitated. Incore conditions are accurately grasped. Constitution: When a neutron is irradiated in a state where a DC voltage is applied between the electrode and the vessel in the device, an ionization current is occured by (n.γ) reaction of the transformed substance as in an ionization chamber, Accordingly, a voltage drop occurs at both ends of the resistor of the radiation signal processing system, as a result of which a neutron flux can be detected. Further, when a sound is generated in the reactor, the monitoring device bottom wall which formed by a piezoelectric element detects the sound-waves. This output signal is picked up by the acoustic signal processing system to judge the generation of sound. (Aizawa, K.)

  15. Control system for a heavy-ion accelerator complex K4 - K10

    International Nuclear Information System (INIS)

    Kotov, V.M.; Pose, R.

    1992-01-01

    Control systems for newly created accelerators, perhaps for the first time, may be designed almost only around international standards for communication and control techniques. This is also true for the project of a control system for the accelerator complex K4-K10 at the Joint Institute for Nuclear Research Dubna. Nevertheless, open systems architecture with construction principles being essential for modern systems of such big devices as particle accelerators leaves designers enough possibilities for solving even very sophisticated problems. (author)

  16. Introduction of a 20 kHz Nd:YVO4 laser into a hybrid quadrupole time-of-flight mass spectrometer for MALDI-MS imaging.

    Science.gov (United States)

    Trim, Paul J; Djidja, Marie-Claude; Atkinson, Sally J; Oakes, Keith; Cole, Laura M; Anderson, David M G; Hart, Philippa J; Francese, Simona; Clench, Malcolm R

    2010-08-01

    A commercial hybrid quadrupole time-of-flight mass spectrometer has been modified for high-speed matrix-assisted laser desorption ionisation (MALDI) imaging using a short-pulse optical technology Nd:YVO(4) laser. The laser operating in frequency-tripled mode (lambda = 355 nm) is capable of delivering 1.5-ns pulses of energy at up to 8 microJ at 5-10 kHz and 3 microJ at 20 kHz. Experiments to improve beam homogeneity and reduce laser speckle by mechanical vibration of the fibre-optic laser delivery system are reported along with data from trial and tissue imaging experiments using the modified instrument. The laser appeared to yield best results for MALDI-MS imaging experiments when operating at repetition rates 5-10 kHz. Combining this with raster imaging allowed images of rat brain sections to be recorded in 37 min. Similarly, images of the distribution of peptides in "on-tissue" digest experiments from tumour tissues were recorded in 1 h and 30 min rather than the 8-h acquisition time previously used. A brief investigation of targeted protein analysis/imaging by multiple reaction monitoring experiments "on-tissue" is reported. A total of 26 transitions were recorded over a 3-s cycle time and images of abundant proteins were successfully recorded.

  17. Device for selective culturing of bacteria used to increase oil bed output

    Energy Technology Data Exchange (ETDEWEB)

    Lazar, J; Zamfirescu, I

    1982-12-15

    The device is patented for selective culturing of bacteria which can be used for increasing oil bed output in order to adapt them to conditions of the field. Development and reproduction of the bacteria are recorded by increase in pressure indicated by the manometer. When the pressure in the container reaches 0.5-0.5 MPa, the gases formed in it are released into the atmosphere through the reverse valve and the hose. Slow rise in pressure in the vessel (usually within 5-10 days) indicates that the nutrient carrier is approaching depletion. After removal of the gases formed because of bacterial activity, the cover is opened and a sample is taken for microbiological analysis and establishment of bacterial growth required for increasing oil output in the given field. When it is established that the developing populations of bacteria correspond to the requirements, then the necessary quantity of bacteria are grown under the same conditions in a battery of similar devices.

  18. Does one need a 4.5 K screen in cryostats of superconducting accelerator devices operating in superfluid helium? lessons from the LHL

    Science.gov (United States)

    Lebrun, Philippe; Parma, Vittorio; Tavian, Laurent

    2014-01-01

    Superfluid helium is increasingly used as a coolant for superconducting devices in particle accelerators: the lower temperature enhances the performance of superconductors in high-field magnets and reduces BCS losses in RF acceleration cavities, while the excellent transport properties of superfluid helium can be put to work in efficient distributed cooling systems. The thermodynamic penalty of operating at lower temperature however requires careful management of the heat loads, achieved inter alia through proper design and construction of the cryostats. A recurrent question appears to be that of the need and practical feasibility of an additional screen cooled by normal helium at around 4.5 K surrounding the cold mass at about 2 K, in such cryostats equipped with a standard 80 K screen. We introduce the issue in terms of first principles applied to the configuration of the cryostats, discuss technical constraints and economical limitations, and illustrate the argumentation with examples taken from large projects confronted with this issue, i.e. CEBAF, SPL, ESS, LHC, TESLA, European X-FEL, ILC.

  19. Nitriding of Ti substrate using energetic ions from plasma focus device

    International Nuclear Information System (INIS)

    Henriquez, A; Bhuyan, H; Favre, M; Bora, B; Wyndham, E; Chuaqui, H; Mändl, S; Gerlach, J W; Manova, D

    2012-01-01

    Plasma Focus (PF) discharge is a pulsed plasma producing discharge that generates high temperature and high density plasma for a short duration. PF devices are known to emit intense ion beams pulses of characteristic energy in the keV to a few MeV range, in a time scale of tens of nanoseconds. We have previously investigated the ion flux and energy spectrum of ion beams emitted from a low energy PF, operating at 20 kV, with 1.8 kJ stored energy. It was observed that the ion beams have wide range of energy and intensity spectra with a clear angular anisotropy. Due to the wide range of ion energy and intensity spectra PF has become a subject of current interest for its applications in material sciences including surface modification and thin film deposition. The purpose of this study is the formation of titanium nitride (TiN) thin film and to investigate the structural properties of the TiN thin films in terms of PF angular positions. Substrates like Ti and Ti/Si were nitrided in a 1.8 kJ PF device at different angular positions with respect to the PF axis in order to correlate their surface properties with ion beam parameters. Preliminary characterizations of the ion implanted substrates have been conducted, using SEM, EDX and XRD. Our results indicate the formation of nanocrystalline TiN thin film only in certain angular positions. Angular dependency of the surface morphology was observed, which shows that the surface features strongly depends on ion beam energy and flux. With increasing angular positions, a reduction in the deposition rate and the sputter rate is observed. A pronounced nanostructured surface is only observed at the axis of the pinched plasma column, indicating the dominant role of sputtering and perhaps melting and fast re-crystallization of the surface in creating the nanostructures.

  20. Mechanisms of astrocytic K(+) clearance and swelling under high extracellular K(+) concentrations.

    Science.gov (United States)

    Murakami, Shingo; Kurachi, Yoshihisa

    2016-03-01

    In response to the elevation of extracellular K(+) concentration ([K(+)]out), astrocytes clear excessive K(+) to maintain conditions necessary for neural activity. K(+) clearance in astrocytes occurs via two processes: K(+) uptake and K(+) spatial buffering. High [K(+)]out also induces swelling in astrocytes, leading to edema and cell death in the brain. Despite the importance of astrocytic K(+) clearance and swelling, the underlying mechanisms remain unclear. Here, we report results from a simulation analysis of astrocytic K(+) clearance and swelling. Astrocyte models were constructed by incorporating various mechanisms such as intra/extracellular ion concentrations of Na(+), K(+), and Cl(-), cell volume, and models of Na,K-ATPase, Na-K-Cl cotransporter (NKCC), K-Cl cotransporter, inwardly-rectifying K(+) (KIR) channel, passive Cl(-) current, and aquaporin channel. The simulated response of astrocyte models under the uniform distribution of high [K(+)]out revealed significant contributions of NKCC and Na,K-ATPase to increases of intracellular K(+) and Cl(-) concentrations, and swelling. Moreover, we found that, under the non-uniform distribution of high [K(+)]out, KIR channels localized at synaptic clefts absorbed excess K(+) by depolarizing the equivalent potential of K(+) (E K) above membrane potential, while K(+) released through perivascular KIR channels was enhanced by hyperpolarizing E K and depolarizing membrane potential. Further analysis of simulated drug effects revealed that astrocyte swelling was modulated by blocking each of the ion channels and transporters. Our simulation analysis revealed controversial mechanisms of astrocytic K(+) clearance and swelling resulting from complex interactions among ion channels and transporters.

  1. Etude Analytique de 510 Cas Biopies Ganglionnaires Chirurgicales

    Directory of Open Access Journals (Sweden)

    HAMID SABETI

    1975-06-01

    Full Text Available 510 cases of surgical lymph node biopsies during a five year periode are reviewed with the following conclusionsThe lymph node biopsy constitues 5% of all the surgical biopsies, The cervical and axillary lymph nodes are the most commonly biopsicd nodes due to their easy accessibility and due to the fact that they drain the lymph from many vital organs: the next most commonly biopsied nodes are the sub-clavicular, grains, mesentric and mediastinal nodes, Among all the lymph node affections the metastatic tumours occupy the first place (23 % followed by the primary tumours (malignant lymphomas 16% and the specific inflammatory lesions (10% , Among the metastic nodes squamous cell carcinoma occupy the first place (8% followed by digestivetract, lung, thyroid glands, breast, testicular, pancreatic, ovarian and gall bladder tumours.

  2. 77 FR 37803 - Customer Clearing Documentation, Timing of Acceptance for Clearing, and Clearing Member Risk...

    Science.gov (United States)

    2012-06-25

    ..., 202-418-6703, [email protected] , Division of Clearing and Risk, and Camden Nunery, Economist, 202-418-5723, Office of the Chief Economist, Commodity Futures Trading Commission, Three Lafayette Centre, 1155...

  3. Delayed-rectifier K channels contribute to contrast adaptation in mammalian retinal ganglion cells.

    Science.gov (United States)

    Weick, Michael; Demb, Jonathan B

    2011-07-14

    Retinal ganglion cells adapt by reducing their sensitivity during periods of high contrast. Contrast adaptation in the firing response depends on both presynaptic and intrinsic mechanisms. Here, we investigated intrinsic mechanisms for contrast adaptation in OFF Alpha ganglion cells in the in vitro guinea pig retina. Using either visual stimulation or current injection, we show that brief depolarization evoked spiking and suppressed firing during subsequent depolarization. The suppression could be explained by Na channel inactivation, as shown in salamander cells. However, brief hyperpolarization in the physiological range (5-10 mV) also suppressed firing during subsequent depolarization. This suppression was selectively sensitive to blockers of delayed-rectifier K channels (K(DR)). In somatic membrane patches, we observed tetraethylammonium-sensitive K(DR) currents that activated near -25 mV. Recovery from inactivation occurred at potentials hyperpolarized to V(rest). Brief periods of hyperpolarization apparently remove K(DR) inactivation and thereby increase the channel pool available to suppress excitability during subsequent depolarization. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Additive manufacturing of lab-on-a-chip devices: promises and challenges

    Science.gov (United States)

    Zhu, Feng; Macdonald, Niall P.; Cooper, Jonathan M.; Wlodkowic, Donald

    2013-12-01

    This work describes a preliminary investigation of commercially available 3D printing technologies for rapid prototyping and low volume fabrication of Lab-on-a-Chip devices. The main motivation of the work was to use off-the-shelf 3D printing methods in order to rapidly and inexpensively build microfluidic devices with complex geometric features and reduce the need to use clear room environment and conventional microfabrication techniques. Both multi-jet modelling (MJM) and stereolithography (SLA) processes were explored. MJM printed devices were fabricated using a HD3500+ (3D Systems) high-definition printer using a thermo-polymer VisiJet Crystal (3D Systems) substratum that allows for a z-axis resolution of 16 μm and 25 μm x-y accuracy. SLA printed devices were produced using a Viper Pro (3D Systems) stereolithography system using Watershed 11122XC (DSM Somos) and Dreve Fototec 7150 Clear (Dreve Otoplastik GmbH) resins which allow for a z-axis resolution of 50 μm and 25 μm x-y accuracy. Fabrication results compared favourably with other forms of rapid prototyping such as laser cut PMMA devices and PDMS moulded microfluidic devices of the same design. Both processes allowed for fabrication of monolithic, optically transparent devices with features in the 100 μm range requiring minimal post-processing. Optical polymer qualities following different post-processing methods were also tested in both brightfield and fluorescence imaging of transgenic zebrafish embryos. Finally, we show that only ethanol-treated Dreve Fototec 7150 Clear resign proved to be non-toxic to human cell lines and fish embryos in fish toxicity assays (FET) requiring further investigation of 3D printing materials.

  5. Clearing and vegetation management issues

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    Clearing and continued management of incompatible plant species is critical to maintaining safe and reliable transmission and distribution lines at British Columbia Hydro. As part of a general review of policies regarding rights-of-way, the clearing of BC Hydro rights-of-way was studied by a task team in order to formulate a set of recommended policies and procedures to guide employees in all rights-of-way decisions, and to provide clear direction for resolution of all rights-of-way issues in a cost-effective manner. Issues reviewed were: clearing standards and line security standardization for transmission circuits; clearing rights for removal of trees or management of vegetation beyond the statutory right-of-way; clearing and vegetation management procedures; tree replacement; arboricultural techniques; periodic reviewing of clearing practices; compensation for tree removal; herbicide use; and heritage and wildlife trees. Justification for the recommendation is provided along with alternate options and costs of compliance

  6. Neutronic analysis of fusion tokamak devices by PHITS

    International Nuclear Information System (INIS)

    Sukegawa, Atsuhiko M.; Takiyoshi, Kouji; Amano, Toshio; Kawasaki, Hiromitsu; Okuno, Koichi

    2011-01-01

    A complete 3D neutronic analysis by PHITS (Particle and Heavy Ion Transport code System) has been performed for fusion tokamak devices such as JT-60U device and JT-60 Superconducting tokamak device (JT-60 Super Advanced). The mono-energetic neutrons (E n =2.45 MeV) of the DD fusion devices are used for the neutron source in the analysis. The visual neutron flux distribution for the estimation of the port streaming and the dose rate around the fusion tokamak devices has been calculated by the PHITS. The PHITS analysis makes it clear that the effect of the port streaming of superconducting fusion tokamak device with the cryostat is crucial and the calculated neutron spectrum results by PHITS agree with the MCNP-4C2 results. (author)

  7. Kir4.1-mediated spatial buffering of K(+)

    DEFF Research Database (Denmark)

    Larsen, Brian Roland; MacAulay, Nanna

    2014-01-01

    Abstract Neuronal activity results in release of K(+) into the extracellular space of the central nervous system. If the excess K(+) is allowed to accumulate, neuronal firing will be compromised by the ensuing neuronal membrane depolarization. The surrounding glial cells are involved in clearing ...

  8. [Digitalization study of sonotubometry device].

    Science.gov (United States)

    Li, Yang; Chen, Shu; Xu, Li; Nong, Dongxiao; Tang, Anzhou; Zhang, Zhiwei

    2014-06-01

    Sonotubometry is wildly used in developed countries, offers a easy, versatile and objective way to assess the function of Eustachian tube. The objectives of this study are to develop a low-cost digitalized device. The digitalized sonotubometry device was made of a personal computer with sound input and output accessories. The PC sound card, connected to a signal amplifier, exported probe band noise, while feedback sound was collected by a microphone. All 36 volunteers (72 ears) were involved in the sonotubometry test with JK-04A and CHN-08, in the conditions of dry-swallowing and wet-swallowing. The data were statistically analyzed using SPSS 13.0. The basic electroacoustic performance of the CHN-08 was acceptable. CHN-08 (7 kHz) detection and JK-04A consistency of kappa index was 0.472; CHN-08 (8 kHz) and JK-04A consistency of kappa index was 0.487; CHN-08 (7 kHz) and CHN-08 (8 kHz) consistency of kappa index was 0.688.Under the JK-04A, CHN-08 (7 kHz) and CHN-08 (8 kHz) three setups, Eustachian tube opening frequency was significantly lower for wet-swallowing than dry-swallowing, P digitalized sonotubometry is successfully developed. Its electroacoustic performance proved acceptable by authority assessments. The detection rate of CHN-08 is in accordance with that of JK-04A moderately. The study revealed that Eustachian tube is opened more easily by dry-swallowing than by wet-swallowing.

  9. Optically stimulated luminescence of Tb{sup 3+}/Sm{sup 3+} doubly doped K{sub 2}YF{sub 5} single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, L.; Marcazzo, J.; Santiago, M.; Caselli, E. [Universidad Nacional del Centro de la Provincia de Buenos Aires, Instituto de Fisica Arroyo Seco, Gral. Pinto 399, B7000GHG, Tandil (Argentina); Khaidukov, N. M., E-mail: jmarcass@exa.unicen.edu.ar [Kurnakov Institute of General and Inorganic Chemistry, RAS, Leninskii Prospekt 31, 119991 Moscow (Russian Federation)

    2014-08-15

    In this work optically stimulated luminescence (OSL) properties of K{sub 2}YF{sub 5} crystals doubly doped with Tb{sup 3+} and Sm{sup 3+} ions have been investigated for the first time. OSL responses for different dopant concentration and for optical stimulation with different wavelengths have been analyzed for each compound. Dosimetric properties of the most efficient composition, namely, K{sub 2}YF{sub 5}:1.0 at.% Tb{sup 3+}; 1.0 at.% Sm{sup 3+}, have been studied. Finally, the possible application of this single crystal as OSL dosimeter has been evaluated. (Author)

  10. Stable structures of Al510–800 clusters and lowest energy sequence of truncated octahedral Al clusters up to 10,000 atoms

    International Nuclear Information System (INIS)

    Wu, Xia; He, Chengdong

    2012-01-01

    Highlights: ► The stable structures of Al 510–800 clusters are obtained with the NP-B potential. ► Al 510–800 clusters adopt truncated octahedral (TO) growth pattern based on complete TOs at Al 405 , Al 586 , and Al 711 . ► The lowest energy sequence of complete TOs up to the size 10,000 is proposed. -- Abstract: The stable structures of Al 510–800 clusters are obtained using dynamic lattice searching with constructed cores (DLSc) method by the NP-B potential. According to the structural growth rule, octahedra and truncated octahedra (TO) configurations are adopted as the inner cores in DLSc method. The results show that in the optimized structures two complete TO structures are found at Al 586 and Al 711 . Furthermore, Al 510–800 clusters adopt TO growth pattern on complete TOs at Al 405 , Al 586 , and Al 711 , and the configurations of the surface atoms are investigated. On the other hand, Al clusters with complete TO motifs are studied up to the size 10,000 by the geometrical construction method. The structural characteristics of complete TOs are denoted by the term “family”, and the growth sequence of Al clusters is investigated. The lowest energy sequence of complete TOs is proposed.

  11. Application of Fast Neutron Activation to Determinate of N, P and K Element Contents in the Sludge

    International Nuclear Information System (INIS)

    Supriyatni E; Yazid M; Nuraini E; Sunardi

    2003-01-01

    The application of fast neutron activation to determinate of N, P and K element contents in the sludge has been performed. The aim of this research is to determine the content of N, P and K elements in the sludge for the possibility of reuse as organic fertilizer. Sludge sample was taken from waste water retainer at Bantul Waste Water Treatment Plant. The sample was dried and ground, then irradiated using 14.7 MeV fast neutron from neutron generator. Result was qualitatively and quantitatively analyses using gamma spectrometer. The result showed that the sludge contains N with energy 511 keV, P with energy 1778 keV and K with energy 1273 keV. The concentration of N is (4.101 ± 0.007) mg/g, P is = (640.510 ± 14.34) mg/g and K = (3.045 ± 0.064) mg/g. (author)

  12. Holmium hafnate: An emerging electronic device material

    Science.gov (United States)

    Pavunny, Shojan P.; Sharma, Yogesh; Kooriyattil, Sudheendran; Dugu, Sita; Katiyar, Rajesh K.; Scott, James F.; Katiyar, Ram S.

    2015-03-01

    We report structural, optical, charge transport, and temperature properties as well as the frequency dependence of the dielectric constant of Ho2Hf2O7 (HHO) which make this material desirable as an alternative high-k dielectric for future silicon technology devices. A high dielectric constant of ˜20 and very low dielectric loss of ˜0.1% are temperature and voltage independent at 100 kHz near ambient conditions. The Pt/HHO/Pt capacitor exhibits exceptionally low Schottky emission-based leakage currents. In combination with the large observed bandgap Eg of 5.6 eV, determined by diffuse reflectance spectroscopy, our results reveal fundamental physics and materials science of the HHO metal oxide and its potential application as a high-k dielectric for the next generation of complementary metal-oxide-semiconductor devices.

  13. Solid-state electronic devices an introduction

    CERN Document Server

    Papadopoulos, Christo

    2014-01-01

    A modern and concise treatment of the solid state electronic devices that are fundamental to electronic systems and information technology is provided in this book. The main devices that comprise semiconductor integrated circuits are covered in a clear manner accessible to the wide range of scientific and engineering disciplines that are impacted by this technology. Catering to a wider audience is becoming increasingly important as the field of electronic materials and devices becomes more interdisciplinary, with applications in biology, chemistry and electro-mechanical devices (to name a few) becoming more prevalent. Updated and state-of-the-art advancements are included along with emerging trends in electronic devices and their applications. In addition, an appendix containing the relevant physical background will be included to assist readers from different disciplines and provide a review for those more familiar with the area. Readers of this book can expect to derive a solid foundation for understanding ...

  14. kLa of stirred tank bioreactors revisited.

    Science.gov (United States)

    Schaepe, S; Kuprijanov, A; Sieblist, C; Jenzsch, M; Simutis, R; Lübbert, A

    2013-12-01

    By means of improved feedback control kLa measurements become possible at a precision and reproducibility that now allow a closer look at the influences of power input and aeration rate on the oxygen mass transfer. These measurements are performed online during running fermentations without a notable impact on the biochemical conversion processes. A closer inspection of the mass transfer during cultivations showed that at least the number of impellers influences mass transfer and mixing: On the laboratory scale, two hollow blade impellers clearly showed a larger kLa than the usually employed three impeller versions when operated at the same agitation power and aeration rate. Hollow blade impellers are preferable under most operational conditions because of their perfect gas handling capacity. Mixing time studies showed that these two impeller systems are also preferable with respect to mixing. Furthermore the widths of the baffle bars depict a significant influence on the kLa. All this clearly supports the fact that it is not only the integral power density that finally determines kLa. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. 75 FR 80828 - Draft Compliance Policy Guide Sec. 510.800 Beverages-Serving Size Labeling; Availability

    Science.gov (United States)

    2010-12-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-D-0575] Draft Compliance Policy Guide Sec. 510.800 Beverages--Serving Size Labeling; Availability AGENCY: Food... comments on the draft CPG to the Division of Dockets Management (HFA-305), Food and Drug Administration...

  16. Measurement of minute local strain in semiconductor materials and electronic devices by using a highly parallel X-ray microbeam

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, J. E-mail: matsui@sci.himeji-tech.ac.jp; Tsusaka, Y.; Yokoyama, K.; Takeda, S.; Katou, M.; Kurihara, H.; Watanabe, K.; Kagoshima, Y.; Kimura, S

    2003-01-01

    We have developed an X-ray microbeam with a small angular divergence by adopting X-ray optics with successive use of asymmetric Bragg reflection from silicon crystals for the both polarizations of the synchrotron X-rays. The microbeam actually obtained is several microns in size and possesses an angular divergence of less than 2 arcsec which enables us to measure the strain of 10{sup -5}-10{sup -6}. By scanning the sample against the microbeam, distribution of the minute local strain in various regions of semiconductor crystals for electronic devices, e.g., the strain around the SiO{sub 2}/Si film edge in silicon devices, the strain in an InGaAsP/InP stripe laser were measured.

  17. A Clustering K-Anonymity Privacy-Preserving Method for Wearable IoT Devices

    OpenAIRE

    Fang Liu; Tong Li

    2018-01-01

    Wearable technology is one of the greatest applications of the Internet of Things. The popularity of wearable devices has led to a massive scale of personal (user-specific) data. Generally, data holders (manufacturers) of wearable devices are willing to share these data with others to get benefits. However, significant privacy concerns would arise when sharing the data with the third party in an improper manner. In this paper, we first propose a specific threat model about the data sharing pr...

  18. Middle School Student Perceptions and Actual Use of Mobile Devices: Highlighting Disconnects in Student Planned and Actual Usage of Mobile Devices in Class

    Science.gov (United States)

    Bartholomew, Scott R.; Reeve, Edward

    2018-01-01

    Discussion surrounding the inclusion of mobile devices in K-12 classrooms has escalated since the early 2000s, and the literature base dedicated to mobile devices, mobile-learning, and e-learning has likewise grown. The majority of the research related to mobile devices and their inclusion in educational settings has largely revolved around…

  19. 30 CFR 285.510 - May MMS reduce or waive my lease or grant payments?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false May MMS reduce or waive my lease or grant... Financial Assurance Requirements Payments § 285.510 May MMS reduce or waive my lease or grant payments? (a) The MMS Director may reduce or waive the rent or operating fee or components of the operating fee...

  20. 21 CFR 510.112 - Antibiotics used in veterinary medicine and for nonmedical purposes; required data.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Antibiotics used in veterinary medicine and for... DRUGS Specific Administrative Rulings and Decisions § 510.112 Antibiotics used in veterinary medicine and for nonmedical purposes; required data. (a) An ad hoc committee, Committee on the Veterinary...

  1. Development of induction current acquisition device based on ARM

    Science.gov (United States)

    Ji, Yanju; Liu, Xiyang; Huang, Wanyu; Yao, Jiang; Yuan, Guiyang; Hui, Luan; Guan, Shanshan

    2018-03-01

    We design an induction current acquisition device based on ARM in order to realize high resolution and high sampling rate of acquisition for the induction current in wire-loop. Considering its characteristics of fast attenuation and small signal amplitude, we use the method of multi-path fusion for noise suppression. In the paper, the design is carried out from three aspects of analog circuit and device selection, independent power supply structure and the electromagnetic interference suppression of high frequency. DMA and ping-pong buffer, as a new data transmission technology, solves real time storage problem of massive data. The performance parameters of ARM acquisition device are tested. The comparison test of ARM acquisition device and cRIO acquisition device is performed at different time constants. The results show that it has 120dB dynamic range, 47kHz bandwidth, 96kHz sampling rate, 5μV the smallest resolution, and its average error value is not more than 4%, which proves the high accuracy and stability of the device.

  2. Pros and cons of symmetrical dual-k spacer technology in hybrid FinFETs

    Science.gov (United States)

    Pradhan, K. P.; Andrade, M. G. C.; Sahu, P. K.

    2016-12-01

    The symmetrical dual-k spacer technology in hybrid FinFETs has been widely explored for better electrostatic control of the fin-based devices in nanoscale region. Since, high-k tangible spacer materials are broadly became a matter of study due to their better immunity to the short channel effects (SCEs) in nano devices. However, the only cause that restricts the circuit designers from using high-k spacer is the unreasonable increasing fringing capacitances. This work quantitatively analyzed the benefits and drawbacks of considering two different dielectric spacer materials symmetrically in either sides of the channel for the hybrid device. From the demonstrated results, the inclusion of high-k spacer predicts an effective reduction in off-state leakage along with an improvement in drive current. However, these devices have paid the cost in terms of a high total gate-to-gate capacitance (Cgg) that consequently results poor cutoff frequency (fT) and delay.

  3. Expanding chromospheres of late G and K supergiants

    Energy Technology Data Exchange (ETDEWEB)

    Mallik, S V

    1986-09-15

    The radiative transfer problem in non-LTE moving atmospheres has been explicitly solved for H..cap alpha.. line profiles. These computations have been done for a schematic model of the line-forming region over a wide range of optical depths and velocity gradients in order to cover the observed characteristics in 23 G and K supergiants. The best theoretical fits yield optical depths in the range 10-500 and velocity fields in the range 0.5-3 Doppler widths. The computed mass-flow rates lie in the range 10/sup -5/-10/sup -7/ Solar Mass yr/sup -1/; the higher the extent of the line-forming region, the lower the mass-loss rates. The effect of the extent on the H..cap alpha.. emission components has also been investigated in some detail.

  4. Clear aligners in orthodontic treatment.

    Science.gov (United States)

    Weir, T

    2017-03-01

    Since the introduction of the Tooth Positioner (TP Orthodontics) in 1944, removable appliances analogous to clear aligners have been employed for mild to moderate orthodontic tooth movements. Clear aligner therapy has been a part of orthodontic practice for decades, but has, particularly since the introduction of Invisalign appliances (Align Technology) in 1998, become an increasingly common addition to the orthodontic armamentarium. An internet search reveals at least 27 different clear aligner products currently on offer for orthodontic treatment. The present paper will highlight the increasing popularity of clear aligner appliances, as well as the clinical scope and the limitations of aligner therapy in general. Further, the paper will outline the differences between the various types of clear aligner products currently available. © 2017 Australian Dental Association.

  5. 17 CFR 39.4 - Procedures for implementing derivatives clearing organization rules and clearing new products.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Procedures for implementing derivatives clearing organization rules and clearing new products. 39.4 Section 39.4 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION DERIVATIVES CLEARING ORGANIZATIONS § 39.4 Procedures for...

  6. Clear cell chondrosarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, R.; David, R.; Cierney, G. III

    1985-01-01

    The clinical, radiologic, and histopathologic features of three cases of clear cell chondrosarcoma are described. On radiographs, this rather benign-appearing tumor resembles a chondroblastoma when it occurs at the end of a long bone, and may occasionally show a calcified matrix. However, it has distinctive tumor cells with a centrally placed vesicular nucleus surrounded by clear cytoplasm. The lesion has a low-grade malignancy and is amenable to en bloc surgical resection, which results in a much better prognosis than that of conventional chondrosarcoma.

  7. Relationships between Access to Mobile Devices, Student Self-Directed Learning, and Achievement

    Science.gov (United States)

    Bartholomew, Scott R.; Reeve, Ed; Veon, Raymond; Goodridge, Wade; Lee, Victor; Nadelson, Louis

    2017-01-01

    Today's students are growing up in a world of constant connectivity, instant information, and ever-changing technological advancements. The increasingly ubiquitous nature of mobile devices among K-12 students has led many to argue for and against the inclusion of these devices in K-12 classrooms. Arguments in favor cite instant access to…

  8. Holmium hafnate: An emerging electronic device material

    International Nuclear Information System (INIS)

    Pavunny, Shojan P.; Sharma, Yogesh; Kooriyattil, Sudheendran; Dugu, Sita; Katiyar, Rajesh K.; Katiyar, Ram S.; Scott, James F.

    2015-01-01

    We report structural, optical, charge transport, and temperature properties as well as the frequency dependence of the dielectric constant of Ho 2 Hf 2 O 7 (HHO) which make this material desirable as an alternative high-k dielectric for future silicon technology devices. A high dielectric constant of ∼20 and very low dielectric loss of ∼0.1% are temperature and voltage independent at 100 kHz near ambient conditions. The Pt/HHO/Pt capacitor exhibits exceptionally low Schottky emission-based leakage currents. In combination with the large observed bandgap E g of 5.6 eV, determined by diffuse reflectance spectroscopy, our results reveal fundamental physics and materials science of the HHO metal oxide and its potential application as a high-k dielectric for the next generation of complementary metal-oxide-semiconductor devices

  9. Holmium hafnate: An emerging electronic device material

    Energy Technology Data Exchange (ETDEWEB)

    Pavunny, Shojan P., E-mail: shojanpp@gmail.com, E-mail: rkatiyar@hpcf.upr.edu; Sharma, Yogesh; Kooriyattil, Sudheendran; Dugu, Sita; Katiyar, Rajesh K.; Katiyar, Ram S., E-mail: shojanpp@gmail.com, E-mail: rkatiyar@hpcf.upr.edu [Department of Physics and Institute for Functional Nanomaterials, University of Puerto Rico, P.O. Box 70377, San Juan, Puerto Rico 00936-8377 (United States); Scott, James F. [Department of Physics and Institute for Functional Nanomaterials, University of Puerto Rico, P.O. Box 70377, San Juan, Puerto Rico 00936-8377 (United States); Department of Physics, Cavendish Laboratory, University of Cambridge, Cambridge CB3 OHE (United Kingdom)

    2015-03-16

    We report structural, optical, charge transport, and temperature properties as well as the frequency dependence of the dielectric constant of Ho{sub 2}Hf{sub 2}O{sub 7} (HHO) which make this material desirable as an alternative high-k dielectric for future silicon technology devices. A high dielectric constant of ∼20 and very low dielectric loss of ∼0.1% are temperature and voltage independent at 100 kHz near ambient conditions. The Pt/HHO/Pt capacitor exhibits exceptionally low Schottky emission-based leakage currents. In combination with the large observed bandgap E{sub g} of 5.6 eV, determined by diffuse reflectance spectroscopy, our results reveal fundamental physics and materials science of the HHO metal oxide and its potential application as a high-k dielectric for the next generation of complementary metal-oxide-semiconductor devices.

  10. Experimental and metabolic modeling evidence for a folate-cleaving side-activity of ketopantoate hydroxymethyltransferase (PanB

    Directory of Open Access Journals (Sweden)

    Jennifer eThiaville

    2016-03-01

    Full Text Available Tetrahydrofolate (THF and its one-carbon derivatives, collectively termed folates, are essential cofact¬ors, but are inherently unstable. While it is clear that chemical oxidation can cleave folates or damage their pterin precursors, very little is known about enzymatic damage to these molec-ules or about whether the folate biosynthesis pathway responds adaptively to damage to its end-pro¬¬ducts. The presence of a duplication of the gene encoding the folate biosynthesis enzyme 6-hydr¬oxymethyl-7,8-dihydropterin pyrophosphokinase (FolK in many sequenced bacterial gen-omes combined with a strong chromosomal clustering of the folK gene with panB, encoding the 5,10-methylene-THF-dependent enzyme ketopantoate hydroxymethyltransferase, led us to infer that PanB has a side activity that cleaves 5,10-methylene-THF, yielding a pterin product that is recycled by FolK. Genetic and metabolic analyses of Escherichia coli strains showed that over-expression of PanB leads to accumulation of the likely folate cleavage product 6-hydroxy¬methyl-pterin and other pterins in cells and medium, and – unexpectedly – to a 46% increase in total fol-ate content. In silico modeling of the folate bio¬syn¬thesis pathway showed that these observations are consistent with the in vivo cleavage of 5,10-methylene-THF by a side-activity of PanB, with FolK-mediated recycling of the pterin cleavage product, and with regulation of folate biosynth-esis by folates or their damage products.

  11. 77 FR 12896 - Self-Regulatory Organizations; Midwest Clearing Corporation; Order Cancelling Clearing Agency...

    Science.gov (United States)

    2012-03-02

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-66458; File No. 600-9] Self-Regulatory Organizations; Midwest Clearing Corporation; Order Cancelling Clearing Agency Registration February 24, 2012. I... Act provides that in the event any self- regulatory organization is no longer in existence or has...

  12. Research on dose setting for radiation sterilization of medical device

    International Nuclear Information System (INIS)

    Zhang Tongcheng; Liu Qingfang; Zhong Hongliang; Mi Zhisu; Wang Chunlei; Jiang Jianping

    2002-01-01

    Objective: To establish the radiation sterilization dose for medical devices using data of bioburden on the medical device. Methods: Firstly determination of recovery ratio and correction coefficient of the microbiological test method was used according to ISO11737 standard, then determination of bioburden on the products, finally the dose setting was completed based on the Method 1 in ISO11137 standard. Results: Fifteen kinds of medical devices were tested. Bioburden range was from 8.6-97271.2 CFU/device, recovery ration range 54.6%-100%, correction co-efficiency range 1.00-1.83, D 10 distribution from 1.40 to 2.82 kGy, verification dose (dose at SAL = 10 -2 ) range 5.1-17.6 kGy and sterilization dose (dose at SAL 10 -6 ) range 17.5-32.5 kGy. Conclusion: One hundred samples of each kind of product were exposed to the pre-determined verification dose and then the sterility test was performed. Each sterility test showed positive number was not greater than two. This indicated that the sterilization dose established for each kind of product was statistically acceptable

  13. Using a Commercial Ethernet PHY Device in a Radiation Environment

    Science.gov (United States)

    Parks, Jeremy; Arani, Michael; Arroyo, Roberto

    2014-01-01

    This work involved placing a commercial Ethernet PHY on its own power boundary, with limited current supply, and providing detection methods to determine when the device is not operating and when it needs either a reset or power-cycle. The device must be radiation-tested and free of destructive latchup errors. The commercial Ethernet PHY's own power boundary must be supplied by a current-limited power regulator that must have an enable (for power cycling), and its maximum power output must not exceed the PHY's input requirements, thus preventing damage to the device. A regulator with configurable output limits and short-circuit protection (such as the RHFL4913, rad hard positive voltage regulator family) is ideal. This will prevent a catastrophic failure due to radiation (such as a short between the commercial device's power and ground) from taking down the board's main power. Logic provided on the board will detect errors in the PHY. An FPGA (field-programmable gate array) with embedded Ethernet MAC (Media Access Control) will work well. The error detection includes monitoring the PHY's interrupt line, and the status of the Ethernet's switched power. When the PHY is determined to be non-functional, the logic device resets the PHY, which will often clear radiation induced errors. If this doesn't work, the logic device power-cycles the FPGA by toggling the regulator's enable input. This should clear almost all radiation induced errors provided the device is not latched up.

  14. Nuclear demagnetisation cooling of a nanoelectronic device

    Science.gov (United States)

    Jones, Alex; Bradley, Ian; Guénault, Tony; Gunnarsson, David; Haley, Richard; Holt, Stephen; Pashkin, Yuri; Penttilä, Jari; Prance, Jonathan; Prunnila, Mika; Roschier, Leif

    We present a new technique for on-chip cooling of electrons in a nanostructure: nuclear demagnetisation of on-chip, thin-film copper refrigerant. We are motivated by the potential improvement in the operation of nanoelectronic devices below 10 mK . At these temperatures, weak electron-phonon coupling hinders traditional cooling, yet here gives the advantage of thermal isolation between the environment and the on-chip electrons, enabling cooling significantly below the base temperature of the host lattice. To demonstrate this we electroplate copper onto the metallic islands of a Coulomb blockade thermometer (CBT), and hence provide a direct thermal link between the cooled copper nuclei and the device electrons. The CBT provides primary thermometry of its internal electron temperature, and we use this to monitor the cooling. Using an optimised demagnetisation profile we observe the electrons being cooled from 9 mK to 4 . 5 mK , and remaining below 5 mK for an experimentally useful time of 1200 seconds. We also suggest how this technique can be used to achieve sub- 1 mK electron temperatures without the use of elaborate bulk demagnetisation stages.

  15. Evaluation of pharmacokinetics, user handling, and tolerability of peginterferon alfa-2a (40 kDa) delivered via a disposable autoinjector device

    Science.gov (United States)

    Varunok, Peter; Lawitz, Eric; Beavers, Kimberly L; Matusow, Gary; Leong, Ruby; Lambert, Nathalie; Bernaards, Coen; Solsky, Jonathan; Brennan, Barbara J; Wat, Cynthia; Bertasso, Anne

    2011-01-01

    Background Peginterferon alfa-2a (40 kDa) is currently administered using a prefilled syringe. The peginterferon alfa-2a disposable autoinjector is a new safety-engineered device designed to facilitate injection and reduce the risk of needlestick injuries. The analysis of two open-label Phase I trials evaluated the pharmacokinetics, successful administration, and tolerability of peginterferon alfa-2a when using the autoinjector. The studies were performed to support the filing and registration of the autoinjector device. Methods In trial 1, 50 healthy adult subjects received one 180 μg dose of peginterferon alfa-2a via the autoinjector. Serial blood samples were collected predose, up to 336 hours following drug administration, and at follow-up (28 ± 3 days post-dosing) for noncompartmental pharmacokinetic analysis. Trial 2 randomized 60 adult patients with chronic hepatitis C to 180 μg peginterferon alfa-2a once weekly by the autoinjector or prefilled syringe for 3 weeks followed by the alternative device (prefilled syringe or autoinjector, respectively) for 3 weeks. Patients also received ribavirin. Administration by the devices was evaluated under direct observation by a study staff member and by patient subjective assessment. Results In trial 1, following a single dose of peginterferon alfa-2a, the maximum plasma concentration was 16.1 ± 5.3 ng/mL (mean ± standard deviation), and area under the concentration time curve (0–168 hours) was 1996 ± 613 ng · hour/mL, similar to that reported using a vial/syringe or prefilled syringe. In trial 2, few patients showed handling difficulties with either device. Generally, patients were observed to be more satisfied and confident, followed instructions better, and successfully initiated injection with the autoinjector versus the prefilled syringe. Patients reported the autoinjector to be more convenient and easier to use. No pain or discomfort was experienced using the autoinjector. The autoinjector safety profile

  16. Tragedy into Drama: An American History of Tourniquet Use in the Current War

    Science.gov (United States)

    2013-09-01

    Tourniquet doctrine refined, expanded in Emergency War Surgery manual 2004 Tourniquets proposed in theater, wait for data is a recipe for inaction; delay...Holcomb adopted a strategy of companies developing field tour- niquets and the Army testing promising candidates, and Walters had a chili cook off–like...the Food and Drug Administration for device consultation (510k pan - elist). In 2007, he received some funds for work for the National Institutes of

  17. Thermonuclear device

    International Nuclear Information System (INIS)

    Yagi, Yasuomi; Takahashi, Ken; Hashimoto, Hiroshi.

    1984-01-01

    Purpose: To improve the plasma confining performances by bringing the irregular magnetic fields nearly to zero and decreasing the absolute value of the irregular magnetic fields at every positions. Constitution: The winding direction of a plurality of coil elements, for instance, double pan cake coils of toroidal coils in a torus type or mirror type thermonuclear device are reversed to each other in their laminating direction, whereby the irregular magnetic fields due to the coil-stepped portions in each toroidal coils are brought nearly to zero. This enables to bring the average irregular magnetic fields as a whole in the thermonuclear device nearly to zero, as well as, decrease the absolute value of the irregular magnetic fields in each positions. Thus, the plasma confining performances can be improved. (Moriyama, K.)

  18. Design of biomedical devices and systems

    CERN Document Server

    Press, CRC

    2014-01-01

    ""This book is a comprehensive overview of all the pieces that need to come together to bring a medical device from an idea to an approved device. It is an impressive compilation of information that is not easily found elsewhere, and included extensive references for every chapter. The writing is clear, yet succinct. The book is well organized with labeled subsections that let the reader find exactly what content he/she may want to explore. Each chapter has exercises that can be used as a self-assessment or to supplement a class.""-Anna Iwaniec Hickerson, Keck Graduate Institute of Appl

  19. Remote controlled stud bolt handling device for reactor pressure vessel

    International Nuclear Information System (INIS)

    Shindo, Takenori; Shigehiro, Katsuya; Ito, Morio; Okada, Kenji

    1988-01-01

    In nuclear power stations, at the time of regular inspection, the works of opening and fixing the upper covers of reactor pressure vessels are carried out for inspecting the inside of reactor pressure vessels and exchanging fuel rods. These upper covers are fastened with many stud bolts, therefore, the works of opening and fixing require a large amount of labor, and are done under the restricted condition of wearing protective clothings and masks. Babcock Hitachi K.K. has completed the development of a remotely controlled automatic bolt tightenig device for this purpose, therefore, its outline is reported. The conventional method of these works and the problems in it are described. The design of the new device aimed at the parallel execution of cleaning screw threads, loosening and tightening nuts, and taking off and putting on nuts and washers, thus contributing to the shortening of regular inspection period, the reduction of the radiation exposure of workers, and the decrease of the number of workers. The function, reliability and endurance of the new device were confirmed by the verifying test using a device made for trial. The device is composed of a stand, a rail and four stations each with a cleaning unit, a stud tensioner and a nut handling unit. (K.I.)

  20. Three-terminal superconducting devices

    International Nuclear Information System (INIS)

    Gallagher, W.J.

    1985-01-01

    The transistor has a number of properties that make it so useful. The authors discuss these and the additional properties a transistor would need to have for high performance applications at temperatures where superconductivity could contribute advantages to system-level performance. These properties then serve as criteria by which to evaluate three-terminal devices that have been proposed for applications at superconducting temperatures. FETs can retain their transistor properties at low temperatures, but their power consumption is too large for high-speed, high-density cryogenic applications. They discuss in detail why demonstrated superconducting devices with three terminals -Josephson effect based devices, injection controlled weak links, and stacked tunnel junction devices such as the superconducting transistor proposed by K. Gray and the quiteron -- each fail to have true transistor-like properties. They conclude that the potentially very rewarding search for a transistor compatible with superconductivity in high performance applications must be in new directions

  1. 76 FR 66763 - Models for Plant-Specific Adoption of Technical Specifications Task Force Traveler TSTF-510...

    Science.gov (United States)

    2011-10-27

    ....'' TSTF-510, Revision 2, is available in the Agencywide Documents Access and Management System (ADAMS... SG Tube Integrity specification (Limiting Condition for Operation (LCO) 3.4.17, LCO 3.4.20, and LCO 3... address implementation issues associated with the inspection periods, and address other administrative...

  2. Definition of multi-state weighted k-out-of-n: F systems

    DEFF Research Database (Denmark)

    Ding, Yi; Wu, Qiuwei; Zio, Enrico

    2012-01-01

    of the Multi-state Weighted k-out-of-n: G System- the Multi-state Weighted k-out-of-n: F System has not been clearly defined and discussed. In this short communication, the basic definition of the Multi-state Weighted k-out-of-n: F System model is proposed. The relationship between the Multi-state Weighted k...

  3. Mineral content as a basis for food selection by western lowland gorillas in a forest clearing.

    Science.gov (United States)

    Magliocca, Florence; Gautier-Hion, Annie

    2002-06-01

    The forests in northwest Republic of Congo contain a number of herbaceous swamp clearings that provide foraging sites for lowland gorillas (G.g. gorilla). A 10-month study at the Maya Nord clearing (Parc National d'Odzala) showed that feeding activities occupied 72% of the time visiting gorillas spent on the clearing. They fed on four plant species: Enydra fluctuans (Asteraceae), Cyperus sp., Pycreus mundtii, and Rhynchospora corymbosa (Cyperaceae) among the 45 species recorded on the clearing. These clearing food species have higher mineral contents (especially Na and Ca) than the dominant Marantaceae species (Haumania liebrechtsiana) that constituted a staple food plant for gorillas in this forest. They also have higher potassium contents and contain less lignin than non-eaten clearing items/species. Finally, the most actively searched for clearing food (Enydra fluctuans) was characterized by the highest amount of Na and Ca. These results suggest that the mineral content (especially in Na, Ca, and/or K) could determine the feeding selectivity of gorillas at the clearing. They also tend to confirm that the amount of fiber plays a deterrent role in food selectivity, as has been found by many authors. The high density of gorillas in that region could result from the combination of the large areas of Marantaceae forests that provide abundant though monotonous food, and the number of clearings that provide sufficient mineral supplies. Clearings should thus be considered as key habitats for the conservation of gorillas. Copyright 2002 Wiley-Liss, Inc.

  4. 21 CFR 866.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY... identifying or inferring the identity of a microorganism directly from clinical material; (7) For detection of...

  5. Device for measuring high temperature heat conductivity of solids and melts

    International Nuclear Information System (INIS)

    Magomedov, Ya.B.; Gadzhiev, G.G.

    1990-01-01

    A modification of a device for measuring heat conductivity by a compensation method when a thermocouple with gadolinium sulfide being used is suggested. Such a device has less error of measurement (8%), wider interval of working temperatures (300-1600K) and it permits to investigate the material in the wide range of heat conductivity values (0.5-30 W/(mxK)). The stainless steel 12Kh18N10T, lanthanum sulfide and melted quartz were used for the device calibration. The results obtained and the literature data on these materials agree well between each other

  6. Electrically Driven Photonic Crystal Nanocavity Devices

    Science.gov (United States)

    2012-01-01

    material, here gallium arsenide and indium arsenide self- assembled quantum dots (QDs). QDs are preferred for the gain medium because they can have...blue points ) and 150 K (green points ). The black lines are linear fits to the above threshold output power of the lasers, which are used to find the...SHAMBAT et al.: ELECTRICALLY DRIVEN PHOTONIC CRYSTAL NANOCAVITY DEVICES 1707 Fig. 13. (a) Tilted SEM picture of a fabricated triple cavity device. The in

  7. Device for monitoring electron-ion ring parameters

    International Nuclear Information System (INIS)

    Tyutyunnikov, S.I.; Shalyapin, V.N.

    1982-01-01

    The invention is classified as the method of collective ion acceleration. The device for electron-ion ring parameters monitoring is described. The invention is aimed at increasing functional possibilities of the device at the expense of the enchance in the number of the ring controlled parameters. The device comprises three similar plane mirrors installed over accelerating tube circumference and a mirror manufactured in the form of prism and located in the tube centre, as well as the system of synchrotron radiation recording and processing. Two plane mirrors are installed at an angle of 45 deg to the vertical axis. The angle of the third plane mirror 3 α and that of prismatic mirror 2 α to the vertical axis depend on geometric parameters of the ring and accelerating tube and they are determined by the expression α=arc sin R K /2(R T -L), where R K - ring radius, R T - accelerating tube radius, L - the height of segment, formed by the mirror and inner surface of the accelerating tube. The device suggested permits to determine longitudinal dimensions of the ring, its velocity and the number of electrons and ions in the ring

  8. DD fusion neutron production at UW-Madison using IEC devices

    Science.gov (United States)

    Fancher, Aaron; Michalak, Matt; Kulcinski, Gerald; Santarius, John; Bonomo, Richard

    2017-10-01

    An inertial electrostatic confinement (IEC) device using spherical, gridded electrodes at high voltage accelerates deuterium ions, allowing for neutrons to be produced within the device from DD fusion reactions. The effects of the device cathode voltage (30-170 kV), current (30-100 mA), and pressure (0.15-1.25 mTorr) on the neutron production rate have been measured. New high voltage capabilities have resulted in the achievement of a steady state neutron production rate of 3.3x108 n/s at 175 kV, 100 mA, and 1.0 mTorr of deuterium. Applications of IEC devices include the production of DD neutrons to detect chemical explosives and special nuclear materials using active interrogation methods. Research supported by US Dept. of Homeland Security Grant 2015-DN-077-AR1095 and the Grainger Foundation.

  9. Characterization of light ion beams generated by a plasma focus device

    International Nuclear Information System (INIS)

    Koo, Bon Cheul

    1999-02-01

    Plasma focus device has been studied as neutron and X-ray sources generated from the high pressure fusion reaction during Z-pinch. Recently, the scope of the device is focused on efficient neutron generation, X-ray lithography, preliminary fusion experiment, and ion/electron beam generation devices. A Hexagonal Beam Generator with six parallel capacitors has been developed and generated ion beams from 30kJ(C=6 μ F, V= 100kV) maximum energy. To find the optimum condition of ion beam generation, the correlation among charging voltage(20∼30kV), operation pressure of chamber(0.1∼5 torr), and length of electrode has been studied. To measure ion beam, a Faraday Cup and 3 Rogowski coils were installed. Energy of ion beam was obtained by adopting time-of -flight method between Rogowski coils

  10. Current contact device for a superconducting magnet coil

    International Nuclear Information System (INIS)

    Hieronymus, H.

    1987-01-01

    The invention concerns a current supply device for a superconducting magnet coil to be shortcircuited, with a separating device per coil end, which contains a fixed cooled contact and a moving contact connected to a power supply device and a mechanical actuating device for closing and opening the contacts. When closing the heated contact on to the cooled contact, relatively large quantities of heat can be transferred to the cooled contact and therefore to the connected superconducting coil end and can cause normal conduction there. The invention therefore provides that the mass ratio of the cooled contact to the moving contact is at least 5:1, preferably at least 10:1, and that the cooled contact part is provided, at the end away from the contact area, with means for increasing the area, for example cooling fins and is connected to the coil end has a thermal resistance between the contact area and the coil end of at least 0.2 k/W, preferably at least 0.5 k/W per 1000 A of current to be transmitted. (orig.) [de

  11. Laterally configured resistive switching device based on transition-metal nano-gap electrode on Gd oxide

    Energy Technology Data Exchange (ETDEWEB)

    Kawakita, Masatoshi; Okabe, Kyota [Department of Physics, Kyushu University, 6-10-1 Hakozaki, Fukuoka 812-8581 (Japan); Kimura, Takashi [Department of Physics, Kyushu University, 6-10-1 Hakozaki, Fukuoka 812-8581 (Japan); Research Center for Quantum Nano-Spin Sciences, Kyushu University, 6-10-1 Hakozaki, Fukuoka 812-8581 (Japan)

    2016-01-11

    We have developed a fabrication process for a laterally configured resistive switching device based on a Gd oxide. A nano-gap electrode connected by a Gd oxide with the ideal interfaces has been created by adapting the electro-migration method in a metal/GdO{sub x} bilayer system. Bipolar set and reset operations have been clearly observed in the Pt/GdO{sub x} system similarly in the vertical device based on GdO{sub x}. Interestingly, we were able to observe a clear bipolar switching also in a ferromagnetic CoFeB nano-gap electrode with better stability compared to the Pt/GdO{sub x} device. The superior performance of the CoFeB/GdO{sub x} device implies the importance of the spin on the resistive switching.

  12. Fiscal 1999 research report. Development of ultralow- loss power device technology (Survey on next-generation practical power semiconductor devices); 1999 nendo choteisonshitsu denryoku soshi gijutsu kaihatsu seika hokokusho. Jisedai power handotai device jitsuyoka chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    This research proposes the clear developmental policy and target for 'Development project of ultralow-loss power device technology' through the research on power electronics or advanced power semiconductor devices as key technology of conversion loss reduction for various power applications and power supply systems. Main research issues are as follows. A bidirectional current switch using P-MOS FETs is promising as an ace of power system interconnection control equipment. IEGT as MOS gate high-power device will be substituted for GTO gradually. SiC devices will play the leading part of low- loss power devices for inverters of power converters, power systems of electric vehicles, Shinkansen and maglev railways, power systems of information and communication systems, and DC power systems. Size and cost reduction of low-noise soft switching as application technology of power devices are possible by using active circuits. Development of high- efficiency low-noise compact inexpensive inverters is an important issue. Countermeasures against various losses of inverters are also described. (NEDO)

  13. Warm Pressurant Gas Effects on the Liquid Hydrogen Bubble Point

    Science.gov (United States)

    Hartwig, Jason W.; McQuillen, John B.; Chato, David J.

    2013-01-01

    This paper presents experimental results for the liquid hydrogen bubble point tests using warm pressurant gases conducted at the Cryogenic Components Cell 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. The purpose of the test series was to determine the effect of elevating the temperature of the pressurant gas on the performance of a liquid acquisition device. Three fine mesh screen samples (325 x 2300, 450 x 2750, 510 x 3600) were tested in liquid hydrogen using cold and warm noncondensible (gaseous helium) and condensable (gaseous hydrogen) pressurization schemes. Gases were conditioned from 0 to 90 K above the liquid temperature. Results clearly indicate a degradation in bubble point pressure using warm gas, with a greater reduction in performance using condensable over noncondensible pressurization. Degradation in the bubble point pressure is inversely proportional to screen porosity, as the coarsest mesh demonstrated the highest degradation. Results here have implication on both pressurization and LAD system design for all future cryogenic propulsion systems. A detailed review of historical heated gas tests is also presented for comparison to current results.

  14. $K^{0}_{S} K^{0}_{S}$ Final State in Two-Photon Collisions and Implications for Glueballs

    CERN Document Server

    Acciarri, M.; Adriani, O.; Aguilar-Benitez, M.; Alcaraz, J.; Alemanni, G.; Allaby, J.; Aloisio, A.; Alviggi, M.G.; Ambrosi, G.; Anderhub, H.; Andreev, Valery P.; Angelescu, T.; Anselmo, F.; Arefev, A.; Azemoon, T.; Aziz, T.; Bagnaia, P.; Bajo, A.; Baksay, L.; Balandras, A.; Baldew, S.V.; Banerjee, S.; Banerjee, Sw.; Barczyk, A.; Barillere, R.; Bartalini, P.; Basile, M.; Batalova, N.; Battiston, R.; Bay, A.; Becattini, F.; Becker, U.; Behner, F.; Bellucci, L.; Berbeco, R.; Berdugo, J.; Berges, P.; Bertucci, B.; Betev, B.L.; Bhattacharya, S.; Biasini, M.; Biland, A.; Blaising, J.J.; Blyth, S.C.; Bobbink, G.J.; Bohm, A.; Boldizsar, L.; Borgia, B.; Bourilkov, D.; Bourquin, M.; Braccini, S.; Branson, J.G.; Brochu, F.; Buffini, A.; Buijs, A.; Burger, J.D.; Burger, W.J.; Cai, X.D.; Capell, M.; Cara Romeo, G.; Carlino, G.; Cartacci, A.M.; Casaus, J.; Castellini, G.; Cavallari, F.; Cavallo, N.; Cecchi, C.; Cerrada, M.; Cesaroni, F.; Chamizo, M.; Chang, Y.H.; Chaturvedi, U.K.; Chemarin, M.; Chen, A.; Chen, G.; Chen, G.M.; Chen, H.F.; Chen, H.S.; Chiefari, G.; Cifarelli, L.; Cindolo, F.; Civinini, C.; Clare, I.; Clare, R.; Coignet, G.; Colino, N.; Costantini, S.; Cotorobai, F.; de la Cruz, B.; Csilling, A.; Cucciarelli, S.; Dai, T.S.; van Dalen, J.A.; D'Alessandro, R.; de Asmundis, R.; Deglon, P.; Degre, A.; Deiters, K.; della Volpe, D.; Delmeire, E.; Denes, P.; DeNotaristefani, F.; De Salvo, A.; Diemoz, M.; Dierckxsens, M.; van Dierendonck, D.; Dionisi, C.; Dittmar, M.; Dominguez, A.; Doria, A.; Dova, M.T.; Duchesneau, D.; Dufournaud, D.; Duinker, P.; Duran, I.; El Mamouni, H.; Engler, A.; Eppling, F.J.; Erne, F.C.; Extermann, P.; Fabre, M.; Falagan, M.A.; Falciano, S.; Favara, A.; Fay, J.; Fedin, O.; Felcini, M.; Ferguson, T.; Fesefeldt, H.; Fiandrini, E.; Field, J.H.; Filthaut, F.; Fisher, P.H.; Fisk, I.; Forconi, G.; Freudenreich, K.; Furetta, C.; Galaktionov, Iouri; Ganguli, S.N.; Garcia-Abia, Pablo; Gataullin, M.; Gau, S.S.; Gentile, S.; Gheordanescu, N.; Giagu, S.; Gong, Z.F.; Grenier, Gerald Jean; Grimm, O.; Gruenewald, M.W.; Guida, M.; van Gulik, R.; Gupta, V.K.; Gurtu, A.; Gutay, L.J.; Haas, D.; Hasan, A.; Hatzifotiadou, D.; Hebbeker, T.; Herve, Alain; Hidas, P.; Hirschfelder, J.; Hofer, H.; Holzner, G.; Hoorani, H.; Hou, S.R.; Hu, Y.; Iashvili, I.; Jin, B.N.; Jones, Lawrence W.; de Jong, P.; Josa-Mutuberria, I.; Khan, R.A.; Kaur, M.; Kienzle-Focacci, M.N.; Kim, D.; Kim, J.K.; Kirkby, Jasper; Kiss, D.; Kittel, W.; Klimentov, A.; Konig, A.C.; Kopal, M.; Kopp, A.; Koutsenko, V.; Kraber, M.; Kraemer, R.W.; Krenz, W.; Kruger, A.; Kunin, A.; Ladron de Guevara, P.; Laktineh, I.; Landi, G.; Lebeau, M.; Lebedev, A.; Lebrun, P.; Lecomte, P.; Lecoq, P.; Le Coultre, P.; Lee, H.J.; Le Goff, J.M.; Leiste, R.; Levtchenko, P.; Li, C.; Likhoded, S.; Lin, C.H.; Lin, W.T.; Linde, F.L.; Lista, L.; Liu, Z.A.; Lohmann, W.; Longo, E.; Lu, Y.S.; Lubelsmeyer, K.; Luci, C.; Luckey, David; Lugnier, L.; Luminari, L.; Lustermann, W.; Ma, W.G.; Maity, M.; Malgeri, L.; Malinin, A.; Mana, C.; Mangeol, D.; Mans, J.; Marian, G.; Martin, J.P.; Marzano, F.; Mazumdar, K.; McNeil, R.R.; Mele, S.; Merola, L.; Meschini, M.; Metzger, W.J.; von der Mey, M.; Mihul, A.; Milcent, H.; Mirabelli, G.; Mnich, J.; Mohanty, G.B.; Moulik, T.; Muanza, G.S.; Muijs, A.J.M.; Musicar, B.; Musy, M.; Napolitano, M.; Nessi-Tedaldi, F.; Newman, H.; Niessen, T.; Nisati, A.; Kluge, Hannelies; Ofierzynski, R.; Organtini, G.; Oulianov, A.; Palomares, C.; Pandoulas, D.; Paoletti, S.; Paolucci, P.; Paramatti, R.; Park, H.K.; Park, I.H.; Passaleva, G.; Patricelli, S.; Paul, Thomas Cantzon; Pauluzzi, M.; Paus, C.; Pauss, F.; Pedace, M.; Pensotti, S.; Perret-Gallix, D.; Petersen, B.; Piccolo, D.; Pierella, F.; Pieri, M.; Piroue, P.A.; Pistolesi, E.; Plyaskin, V.; Pohl, M.; Pojidaev, V.; Postema, H.; Pothier, J.; Prokofev, D.O.; Prokofiev, D.; Quartieri, J.; Rahal-Callot, G.; Rahaman, M.A.; Raics, P.; Raja, N.; Ramelli, R.; Rancoita, P.G.; Ranieri, R.; Raspereza, A.; Raven, G.; Razis, P.; Ren, D.; Rescigno, M.; Reucroft, S.; Riemann, S.; Riles, Keith; Rodin, J.; Roe, B.P.; Romero, L.; Rosca, A.; Rosier-Lees, S.; Rubio, J.A.; Ruggiero, G.; Rykaczewski, H.; Saremi, S.; Sarkar, S.; Salicio, J.; Sanchez, E.; Sanders, M.P.; Schafer, C.; Schegelsky, V.; Schmidt-Kaerst, S.; Schmitz, D.; Schopper, H.; Schotanus, D.J.; Schwering, G.; Sciacca, C.; Seganti, A.; Servoli, L.; Shevchenko, S.; Shivarov, N.; Shoutko, V.; Shumilov, E.; Shvorob, A.; Siedenburg, T.; Son, D.; Smith, B.; Spillantini, P.; Steuer, M.; Stickland, D.P.; Stone, A.; Stoyanov, B.; Straessner, A.; Sudhakar, K.; Sultanov, G.; Sun, L.Z.; Sushkov, S.; Suter, H.; Swain, J.D.; Szillasi, Z.; Sztaricskai, T.; Tang, X.W.; Tauscher, L.; Taylor, L.; Tellili, B.; Timmermans, Charles; Ting, Samuel C.C.; Ting, S.M.; Tonwar, S.C.; Toth, J.; Tully, C.; Tung, K.L.; Uchida, Y.; Ulbricht, J.; Valente, E.; Vesztergombi, G.; Vetlitsky, I.; Vicinanza, D.; Viertel, G.; Villa, S.; Vivargent, M.; Vlachos, S.; Vodopianov, I.; Vogel, H.; Vogt, H.; Vorobev, I.; Vorobov, A.A.; Vorvolakos, A.; Wadhwa, M.; Wallraff, W.; Wang, M.; Wang, X.L.; Wang, Z.M.; Weber, A.; Weber, M.; Wienemann, P.; Wilkens, H.; Wu, S.X.; Wynhoff, S.; Xia, L.; Xu, Z.Z.; Yamamoto, J.; Yang, B.Z.; Yang, C.G.; Yang, H.J.; Yang, M.; Ye, J.B.; Yeh, S.C.; Zalite, A.; Zalite, Yu.; Zhang, Z.P.; Zhu, G.Y.; Zhu, R.Y.; Zichichi, A.; Zilizi, G.; Zimmermann, B.; Zoller, M.

    2001-01-01

    The $\\mbox{K}^0_{\\rm S}\\mbox{K}^0_{\\rm S}$ final state in two-photon collisions is studied with the L3 detector at LEP. The mass spectrum is dominated by the formation of the $f'_{2}$(1525) tensor meson in the helicity-two state with a two-photon width times the branching ratio into $\\rm K\\bar{K}$ of $76 \\pm\\, 6 \\pm\\, 11\\, {\\rm eV}$. A clear signal for the formation of the f$_{\\rm J}$(1710) is observed and it is found to be dominated by the spin-two helicity-two state. No resonance is observed in the mass region around $2.2 \\,{\\rm GeV}$ and an upper limit of $1.4 \\,{\\rm eV}$ at 95\\% C.L. is derived for the two-photon width times the branching ratio into $\\mbox{K}^0_{\\rm S}\\mbox{K}^0_{\\rm S}$ for the glueball candidate $\\xi(2230)$.

  15. Short-Circuit Degradation of 10-kV 10-A SiC MOSFET

    DEFF Research Database (Denmark)

    Eni, Emanuel-Petre; Beczkowski, Szymon; Munk-Nielsen, Stig

    2017-01-01

    The short-circuit behavior of power devices is highly relevant for converter design and fault protection. In this work, the degradation during short-circuit of a 10 kV 10 A 4H-SiC MOSFET is investigated at 6 kV DC-link voltage. The study aims to present the behavior of the device during short-circuit...... transients as it sustains increasing short-circuit pulses during its life-time. As the short-circuit pulse length increases, degradation of the device can be observed in periodically performed characterizations. The initial degradation seems to be associated with the channel region, and continuous stressing...

  16. Modeling and Simulation for an 8 kW Three-Phase Grid-Connected Photo-Voltaic Power System

    Science.gov (United States)

    Cen, Zhaohui

    2017-09-01

    Gird-connected Photo-Voltaic (PV) systems rated as 5-10 kW level have advantages of scalability and energy-saving, so they are very typical for small-scale household solar applications. In this paper, an 8 kW three-phase grid-connected PV system model is proposed and studied. In this high-fidelity model, some basic PV system components such as solar panels, DC-DC converters, DC-AC inverters and three-phase utility grids are mathematically modelled and organized as a complete simulation model. Also, an overall power controller with Maximum Power Point Control (MPPT) is proposed to achieve both high-efficiency for solar energy harvesting and grid-connection stability. Finally, simulation results demonstrate the effectiveness of the PV system model and the proposed controller, and power quality issues are discussed.

  17. Modeling and Simulation for an 8 kW Three-Phase Grid-Connected Photo-Voltaic Power System

    Directory of Open Access Journals (Sweden)

    Cen Zhaohui

    2017-09-01

    Full Text Available Gird-connected Photo-Voltaic (PV systems rated as 5-10 kW level have advantages of scalability and energy-saving, so they are very typical for small-scale household solar applications. In this paper, an 8 kW three-phase grid-connected PV system model is proposed and studied. In this high-fidelity model, some basic PV system components such as solar panels, DC-DC converters, DC-AC inverters and three-phase utility grids are mathematically modelled and organized as a complete simulation model. Also, an overall power controller with Maximum Power Point Control (MPPT is proposed to achieve both high-efficiency for solar energy harvesting and grid-connection stability. Finally, simulation results demonstrate the effectiveness of the PV system model and the proposed controller, and power quality issues are discussed.

  18. Waste heat recovering device for reactors

    International Nuclear Information System (INIS)

    Sonoda, Masanobu; Shiraishi, Tadashi; Mizuno, Hiroyuki; Sekine, Yasuhiro.

    1982-01-01

    Purpose: To enable utilization of auxiliary-equipment-cooling water from a non-regenerative heat exchanger as a heat source, as well as prevent radioactive contamination. Constitution: A water warming device for recovering the heat of auxiliary equipment cooling water from a non-regenerative heat exchanger is disposed at the succeeding stage of the heat exchanger. Heat exchange is performed in the water warming device between the auxiliary equipment cooling water and a heat source water set to a higher pressure and recycled through the water warming device. The heat recovered from the auxiliary equipment cooling water is utilized in the heat source water for operating relevant equipments. (Aizawa, K.)

  19. An ultra miniature pinch-focus discharge

    International Nuclear Information System (INIS)

    Soto, L.; Pavez, C.; Moreno, J.; Pavez, C.; Barbaglia, M.; Clausse, A.

    2004-01-01

    As a way to investigate the minimum energy to produce a pinch plasma focus discharge, an ultra miniature device has been designed and constructed (nano focus NF: 5 nF, 5-10 kV, 5-10 kA, 60-250 mJ, 16 ns time to peak current). Sub-millimetric anode radius covered by a coaxial insulator were used for experiments in hydrogen. Evidence of pinch was observed in electrical signals in discharges operating at 60 mJ. A single-frame image converter camera (4 ns exposure) was used to obtain plasma images in the visible range. The dynamics observed from the photographs is consistent with: a) formation of a plasma sheath close to the insulator surface, b) fast axial motion of the plasma sheath, c) radial compression over the anode, and d) finally the plasma is detached from the anode in the axial direction. The total time since stage a) to d) was observed to be about 30 ns. X ray and neutron emission is being studied. Neutron yield of the order of 10 3 neutrons per shot is expected for discharges operating in deuterium at 10 kA. (authors)

  20. Beam Transport Devices for the 10 kW IR Free Electron Laser

    International Nuclear Information System (INIS)

    Lawrence Dillon-Townes; Michael Bevins; David Kashy; Stephanie Slachtouski; Ronald Lassiter; George Neil; Michelle Shinn; Joseph Gubeli; Christopher Behre; David Douglas; David W. Waldman; George Biallas; Lawrence Munk; Christopher Gould

    2005-01-01

    Beam transport components for the 10kW IR Free Electron Laser (FEL) at Thomas Jefferson National Accelerator Facility (Jefferson Lab) were designed to manage (1) electron beam transport and (2) photon beam transport. An overview of the components will be presented in this paper. The electron beam transport components were designed to address RF heating, maintain an accelerator transport vacuum of 1 x 10 -8 torr, deliver photons to the optical cavity, and provide 50 kW of beam absorption during the energy recovery process. The components presented include a novel shielded bellows, a novel zero length beam clipper, a one decade differential pumping station with a 7.62 cm (3.0 inch) aperture, and a 50 kW beam dump. The photon beam transport components were designed to address the management of photons delivered by the accelerator transport. The optical cavity manages the photons and optical transport delivers the 10 kW of laser power to experimental labs. The optical cavity component presented is a unique high reflector vessel and the optical transport component presented is a turning mirror cassette

  1. Conceptual design of a high luminosity 510 MeV collider

    International Nuclear Information System (INIS)

    Pellegrini, C.; Robin, D.; Cornacchia, M.

    1991-01-01

    The authors discuss the magnetic lattice design of a high luminosity 510 MeV electron-positron collider, based on high field superconduction bending dipoles. The design criteria are flexibility in the choice of the tune and beta functions at the interaction point, horizontal emittance larger than 1 mm mrad to produce a luminosity larger than 10 32 cm -2 s -1 , large synchrotron radiation damping rate, and large momentum compaction. The RF system parameter are chosen to provide a short bunch length also when the beam energy spread is determined by the microwave instability. A satisfactory ring dynamic aperature, and a simultaneous small value of the horizontal and vertical beta function at the interaction point, the authors expect will be achieved by using Cornacchia-Halbach modified sextupoles

  2. Gamma Radiation (5-10 Gy) Impairs Neuronal Function in the Guinea Pig Hippocampus

    Science.gov (United States)

    1993-01-01

    Radiation (5-10 Gy) Impairs Neuronal Function in the Guinea Pig Hippocampus TERRY C. PELLMAR AND DENNIS L. LEPINSKI Ph.vsiology Department..Irmned Forces...L. Gamma Radiation ioral effects. Within hours of irradiation with 10 Gy and (5- 10 Gy) Impairs Neuronal Function in the Guinea Pig Hippo- less...acti v- Guinea pigs were exposed to 5 and 10 Gy ’y radiation. Hippo- ity (9) are evident. campal brain slices were isolated 30 min, I day, 3 days and 5

  3. Rapidly curable electrically conductive clear coatings

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, Mark P.; Anderson, Lawrence G.; Post, Gordon L.

    2018-01-16

    Rapidly curable electrically conductive clear coatings are applied to substrates. The electrically conductive clear coating includes to clear layer having a resinous binder with ultrafine non-stoichiometric tungsten oxide particles dispersed therein. The clear coating may be rapidly cured by subjecting the coating to infrared radiation that heats the tungsten oxide particles and surrounding resinous binder. Localized heating increases the temperature of the coating to thereby thermally cure the coating, while avoiding unwanted heating of the underlying substrate.

  4. Isotope geochemistry of brasiliano age, coarsely porphyritic, K-calc-alkalic granitoids and associated K-diorites, northeast Brazil

    International Nuclear Information System (INIS)

    Sial, A.N.; Mariano, G.; Ferreira, V.P.

    1989-01-01

    Several porphyritic, K-calc-alkalic were syntectonically intruded in NE Brazil during the Brasiliano orogeny. They show bi-(qz) diorite and coarsely porphyritic granodiorite to qz monzonite ('Itaporanga-type') in commingling zones on a scale of cm to m irrespective of whether plutons are at the margins of the NE-trending Cachoeirinha-Salgueiro Fold Belt (CSF) or intruded metasediments of the Serido Fold Belt (SFB). The bi(qz) diorites are found in magmatic or stromatic structures and narrow dikes wich intruded the felsic facies. SiO 2 in the porphyritic facies ranges from 61 to 72% with K 2 O usually > Na 2 O. K-diorities exhibit SiO 2 from 50 to 58%, MgO from 2 to 10% and K 2 O from 2 to 5%. Both facies are usually Ba and Sr-enriched, with similar, highly fractionated REE patterns, lacking free of Eu anomaly. Quartz 180 values are considered homogeneous on the scale of these intrusions in the CSF, (8 to 10 per milSMOW). Bi-(qz) diorites exhibit slightly higher 180 (9.5 to 10.5 per milSMOW). In the SFB both facies are lower than 180. The oxygen isotope data for the porphyritic facies are compatible with I-type source with some metasedimentary component of variable proportion. As bi(qz) diorites were formed pre- to post-porphyritic facies intrusion, their high LREE, K and 180 reflect their source rather than the interaction with the potassic felsic magma. Preliminarly sulfur isotope values suggest that porphyritic facies of granitoids in the SBF are lower in 34S than those in the CSF. Rb and Sr isotopes reflect source heterogeneity, complicated by mixing relations. Ages span from 510 to 630 Ma suggesting that the Itaporanga-type association was formed during uplift and cooling of the Pan-African I and onset of the Pan-African II orogenies, recognized in West Africa. (author) [pt

  5. Radon daughters and work at display devices

    International Nuclear Information System (INIS)

    Falk, R.; Nyblom, L.

    1986-01-01

    It has been shown that ions and electrically charged particles in the air can be transported in the electrostatic field between a face and a display device to either the face or the screen. Radon daughters can occur as ions, or sitting on charged particles. This prestudy shows that radon daughters were manifold concentrated on the face of a doll placed in front of a display device, or in a electrostatic field of the kind typical for displaying devices. The radiation dose, in the skin from the radon daughters in an ordinary office environment plus the addition caused by work at a display device, is not strong enough to cause skin damages alone. (BoK)

  6. Exploratory analysis of green certificates devices for the promotion of the renewable energies (PROMER-PE- 5-10). Synthesis report; Analyse exploratoire des dispositifs de certificats verts pour la promotion des energies renouvelables (PROMER-PE 5-10). Rapport de synthese

    Energy Technology Data Exchange (ETDEWEB)

    Menanteau, P. [Grenoble-1 Univ., Lab. d' Economie de la Production et de l' Integration Internationale (LEPII-EPE CNRS), 38 - Grenoble (France)

    2005-07-01

    The PROMER project aims to study the efficiency of assistance devices for the renewable energies in a context of electric market liberalization. This synthesis report presents the main results and the economic interest of a green certificates market in the European Union. It shows also that the device efficiency is uncertain concerning the capacities increase and the costs decrease process, because of new risks for the investments. (A.L.B.)

  7. Radioactive gas storage device

    International Nuclear Information System (INIS)

    Seki, Eiji; Kobayashi, Yoshihiro.

    1989-01-01

    The present invention concerns a device of ionizing radioactive gases to be processed in gaseous nuclear fission products in nuclear fuel reprocessing plants, etc., and injecting them into metal substrates for storage. The device comprises a vessel for a tightly closed type outer electrode in which gases to be processed are introduced, an electrode disposed to the inside of the vessel and the target material, a high DC voltage power source for applying high voltage to the electrodes, etc. There are disposed a first electric discharging portion for preparting discharge plasma for ion injection of different electrode distance and a second electric discharging portion for causing stable discharge between the vessel and the electrode. The first electric discharging portion for the ion injection provides an electrode distance suitable to acceleration sputtering and the second electric discharging portion is used for stable discharge. Accordingly, if the gas pressure in the radioactive gas storage device is reduced by the external disturbance, etc., since the second electric discharging portion satisfies the electric discharging conditions, the device can continue electric discharge. (K.M.)

  8. 49 CFR 510.3 - Compulsory process, the service thereof, claims for confidential treatment, and terms of compliance.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Compulsory process, the service thereof, claims... OF TRANSPORTATION INFORMATION GATHERING POWERS § 510.3 Compulsory process, the service thereof... description of the documents or things to be produced. (c) Service of the compulsory processes specified in...

  9. Low Vision Devices and Training

    Directory of Open Access Journals (Sweden)

    Imran Azam Butt

    2004-01-01

    Full Text Available Vision is the ability to see with a clear perception of detail, colour and contrast, and to distinguish objects visually. Like any other sense, vision tends to deteriorate or diminish naturally with age. In most cases, reduction in visual capability can be corrected with glasses, medicine or surgery. However, if the visual changes occur because of an incurable eye disease, condition or injury, vision loss can be permanent. Many people around the world with permanent visual impairment have some residual vision which can be used with the help of low vision services, materials and devices. This paper describes different options for the enhancement of residual vision including optical and non-optical devices and providing training for the low vision client.

  10. Skin optical clearing potential of disaccharides

    Science.gov (United States)

    Feng, Wei; Shi, Rui; Ma, Ning; Tuchina, Daria K.; Tuchin, Valery V.; Zhu, Dan

    2016-08-01

    Skin optical clearing can significantly enhance the ability of biomedical optical imaging. Some alcohols and sugars have been selected to be optical clearing agents (OCAs). In this work, we paid attention to the optical clearing potential of disaccharides. Sucrose and maltose were chosen as typical disaccharides to compare with fructose, an excellent monosaccharide-OCA, by using molecular dynamics simulation and an ex vivo experiment. The experimental results indicated that the optical clearing efficacy of skin increases linearly with the concentration for each OCA. Both the theoretical predication and experimental results revealed that the two disaccharides exerted a better optical clearing potential than fructose at the same concentration, and sucrose is optimal. Since maltose has an extremely low saturation concentration, the other two OCAs with saturation concentrations were treated topically on rat skin in vivo, and optical coherence tomography imaging was applied to monitor the optical clearing process. The results demonstrated that sucrose could cause a more significant increase in imaging depth and signal intensity than fructose.

  11. "O.K. Where's the Remote?" Children, Families, and Remote Control Devices.

    Science.gov (United States)

    Krendl, Kathy A.; And Others

    This paper, part of a larger study of new television technologies, examines how preschool children integrate remote control devices (RCDs) into their television viewing behavior, preschoolers' competence with and knowledge of RCDs, and the role of the RCD in shaping family viewing styles. Subjects, 50 children aged 4 to 6 years attending 3…

  12. Latching device for nuclear reactor housing

    International Nuclear Information System (INIS)

    Barnes, J.G.

    1981-01-01

    A latching device for use in liquid metal cooled nuclear reactors is described which is not detached under normal operational loads on the absorber sub-assemblies. The sub-assemblies are however easily detached for repair or replacement. (U.K.)

  13. NATO Advanced Study Institute on Physics of Submicron Semiconductor Devices

    CERN Document Server

    Ferry, David; Jacoboni, C

    1988-01-01

    The papers contained in the volume represent lectures delivered as a 1983 NATO ASI, held at Urbino, Italy. The lecture series was designed to identify the key submicron and ultrasubmicron device physics, transport, materials and contact issues. Nonequilibrium transport, quantum transport, interfacial and size constraints issues were also highlighted. The ASI was supported by NATO and the European Research Office. H. L. Grubin D. K. Ferry C. Jacoboni v CONTENTS MODELLING OF SUB-MICRON DEVICES.................. .......... 1 E. Constant BOLTZMANN TRANSPORT EQUATION... ... ...... .................... 33 K. Hess TRANSPORT AND MATERIAL CONSIDERATIONS FOR SUBMICRON DEVICES. . .. . . . . .. . . . .. . .. . .... ... .. . . . .. . . . .. . . . . . . . . . . 45 H. L. Grubin EPITAXIAL GROWTH FOR SUB MICRON STRUCTURES.................. 179 C. E. C. Wood INSULATOR/SEMICONDUCTOR INTERFACES.......................... 195 C. W. Wilms en THEORY OF THE ELECTRONIC STRUCTURE OF SEMICONDUCTOR SURFACES AND INTERFACES...................

  14. Beyond the International Linear Collider Driven by FEL with Energy Recovery at 5-10TeV

    CERN Document Server

    Hajima, R

    2005-01-01

    The international linear collider (ILC) at the extreme high energy frontier provides the best hope for the scientist to probe the finenst structure of matter and its origin and perhaps even the origin of the Universe. The technology that employs is based on superconducting RF technology. This technology may usher in a new era for the development of superconducting accelerator technology. On the other hand, the gradient that is allowed in such an accelerator is limited. If one wishes something beyond this after one learns the physics at such high energies(~0.5TeV) and utilizing such technology, one may need a new way to employ the supeconducting technology in providing high gradient compact accelerators. Inspired by a former work of 5-TeV colliders based on solid-state tera-watt lasers [1], we explore 5-10 TeV linear colliders driven by free-electron lasers equipped with energy-recovery system. A preliminary design study suggests that a 5-10 TeV collider with the luminosity of 10(34) can be realized by multi-s...

  15. Study on Automatic Solar Heat Insulated and Cooling Device of Car

    Directory of Open Access Journals (Sweden)

    Chen Gui-Yue

    2017-01-01

    Full Text Available In view of the common device for heat insulated and cooling of car, an improved new scheme which drove by solar energy is put forward. In this study, the transmission device are arranged inside the automobile, the thin-film solar is composited into the heat insulated and cooling material. Thus, the whole device can be driven by the energy from the photovoltaic conversion, which is clear and zero-pollution. The theoretical energy consumptions and preventable gas emissions are calculated to verify the environmental savings of the device. The results show that it has promising application prospect since it is not only environmentally friendly but also save and convenient as compared to the conventional device.

  16. Overview of Air Liquide refrigeration systems between 1.8 K and 200 K

    Science.gov (United States)

    Gondrand, C.; Durand, F.; Delcayre, F.; Crispel, S.; Baguer, G. M. Gistau

    2014-01-01

    Cryogenic refrigeration systems are necessary for numerous applications. Gas purification and distillation require temperatures between 15 K and 200 K depending on the application, space simulation chambers down to 15 K, superconductivity between 1.8 K and up to 75 K (magnets, cavities or HTS devices like cables, FCL, SMES, etc), Cold Neutron Sources between 15 and 20 K, etc. Air Liquide Advanced Technologies is designing and manufacturing refrigerators since 60 years to satisfy those needs. The step by step developments achieved have led to machines with higher efficiency and reliability. In 1965, reciprocating compressors and Joule Thomson expansion valves were used. In 1969, centripetal expanders began to be used. In 1980, oil lubricated screw compressors took the place of reciprocating compressors and a standard range of Claude cycle refrigerators was developed: the HELIAL series. 1980 was also the time for cryogenic centrifugal compressor development. In 2011, driven by the need for lower operational cost (high efficiency and low maintenance), cycle oil free centrifugal compressors on magnetic bearings were introduced instead of screw compressors. The power extracted by centripetal expanders was recovered. Based on this technology, a range of Turbo-Brayton refrigerators has been designed for temperatures between 40 K and 150 K. On-going development will enable widening the range of Turbo-Brayton refrigerators to cryogenic temperatures down to 15 K.. Cryogenic centrifugal circulators have been developed in order to answer to an increasing demand of 4 K refrigerators able to distribute cold power.

  17. Overview of Air Liquide refrigeration systems between 1.8 K and 200 K

    International Nuclear Information System (INIS)

    Gondrand, C.; Durand, F.; Delcayre, F.; Crispel, S.; Baguer, G. M. Gistau

    2014-01-01

    Cryogenic refrigeration systems are necessary for numerous applications. Gas purification and distillation require temperatures between 15 K and 200 K depending on the application, space simulation chambers down to 15 K, superconductivity between 1.8 K and up to 75 K (magnets, cavities or HTS devices like cables, FCL, SMES, etc), Cold Neutron Sources between 15 and 20 K, etc. Air Liquide Advanced Technologies is designing and manufacturing refrigerators since 60 years to satisfy those needs. The step by step developments achieved have led to machines with higher efficiency and reliability. In 1965, reciprocating compressors and Joule Thomson expansion valves were used. In 1969, centripetal expanders began to be used. In 1980, oil lubricated screw compressors took the place of reciprocating compressors and a standard range of Claude cycle refrigerators was developed: the HELIAL series. 1980 was also the time for cryogenic centrifugal compressor development. In 2011, driven by the need for lower operational cost (high efficiency and low maintenance), cycle oil free centrifugal compressors on magnetic bearings were introduced instead of screw compressors. The power extracted by centripetal expanders was recovered. Based on this technology, a range of Turbo-Brayton refrigerators has been designed for temperatures between 40 K and 150 K. On-going development will enable widening the range of Turbo-Brayton refrigerators to cryogenic temperatures down to 15 K.. Cryogenic centrifugal circulators have been developed in order to answer to an increasing demand of 4 K refrigerators able to distribute cold power

  18. Overview of Air Liquide refrigeration systems between 1.8 K and 200 K

    Energy Technology Data Exchange (ETDEWEB)

    Gondrand, C.; Durand, F.; Delcayre, F.; Crispel, S. [AL-AT, 2 rue de Clémencières, 38360 Sassenage (France); Baguer, G. M. Gistau [CRYOGUY, 44, chemin de la Buisse, 38330 Biviers (France)

    2014-01-29

    Cryogenic refrigeration systems are necessary for numerous applications. Gas purification and distillation require temperatures between 15 K and 200 K depending on the application, space simulation chambers down to 15 K, superconductivity between 1.8 K and up to 75 K (magnets, cavities or HTS devices like cables, FCL, SMES, etc), Cold Neutron Sources between 15 and 20 K, etc. Air Liquide Advanced Technologies is designing and manufacturing refrigerators since 60 years to satisfy those needs. The step by step developments achieved have led to machines with higher efficiency and reliability. In 1965, reciprocating compressors and Joule Thomson expansion valves were used. In 1969, centripetal expanders began to be used. In 1980, oil lubricated screw compressors took the place of reciprocating compressors and a standard range of Claude cycle refrigerators was developed: the HELIAL series. 1980 was also the time for cryogenic centrifugal compressor development. In 2011, driven by the need for lower operational cost (high efficiency and low maintenance), cycle oil free centrifugal compressors on magnetic bearings were introduced instead of screw compressors. The power extracted by centripetal expanders was recovered. Based on this technology, a range of Turbo-Brayton refrigerators has been designed for temperatures between 40 K and 150 K. On-going development will enable widening the range of Turbo-Brayton refrigerators to cryogenic temperatures down to 15 K.. Cryogenic centrifugal circulators have been developed in order to answer to an increasing demand of 4 K refrigerators able to distribute cold power.

  19. Mini array of quantum Hall devices based on epitaxial graphene

    International Nuclear Information System (INIS)

    Novikov, S.; Lebedeva, N.; Hämäläinen, J.; Iisakka, I.; Immonen, P.; Manninen, A. J.; Satrapinski, A.

    2016-01-01

    Series connection of four quantum Hall effect (QHE) devices based on epitaxial graphene films was studied for realization of a quantum resistance standard with an up-scaled value. The tested devices showed quantum Hall plateaux R H,2 at a filling factor v = 2 starting from a relatively low magnetic field (between 4 T and 5 T) when the temperature was 1.5 K. The precision measurements of quantized Hall resistance of four QHE devices connected by triple series connections and external bonding wires were done at B = 7 T and T = 1.5 K using a commercial precision resistance bridge with 50 μA current through the QHE device. The results showed that the deviation of the quantized Hall resistance of the series connection of four graphene-based QHE devices from the expected value of 4×R H,2  = 2 h/e 2 was smaller than the relative standard uncertainty of the measurement (<1 × 10 −7 ) limited by the used resistance bridge.

  20. Thermal properties and burning efficiency of crude oils and refined fuel oil

    DEFF Research Database (Denmark)

    van Gelderen, Laurens; Alva, Wilson Ulises Rojas; Mindykowski, Pierrick Anthony

    2017-01-01

    The thermal properties and burning efficiencies of fresh and weathered crude oils and a refined fuel oil were studied in order to improve the available input data for field ignition systems for the in-situ burning of crude oil on water. The time to ignition, surface temperature upon ignition, heat......-cooled holder for a cone calorimeter under incident heat fluxes of 0, 5, 10, 20, 30, 40 and 50 kW/m2. The results clearly showed that the weathered oils were the hardest to ignite, with increased ignition times and critical heat fluxes of 5-10 kW/m2. Evaporation and emulsification were shown...

  1. VCA-DVC VMware certified associate on vSphere study guide VCAD-510

    CERN Document Server

    Schmidt, Robert

    2015-01-01

    Use this expert guide to prepare for the VCA-DCV exam VCA-DCV VMware Certified Associate on vSphere Study Guide: VCAD-510 is a comprehensive study guide for the VMware Certified Associate - Data Center Virtualization exam. Hands-on examples, real-world scenarios, and expert review questions cover the full exam blueprint, and the companion website offers a suite of tools to help you prepare for the exam including practice exams, electronic flashcards, and a glossary of key terms. In addition, the website includes videos that demonstrate how to complete the more challenging tasks. Focused on p

  2. Design control considerations for biologic-device combination products.

    Science.gov (United States)

    Anderson, Dave; Liu, Roger; Anand Subramony, J; Cammack, Jon

    2017-03-01

    Combination products are therapeutic and diagnostic medical products that combine drugs, devices, and/or biological products with one another. Historically, biologics development involved identifying efficacious doses administered to patients intravenously or perhaps by a syringe. Until fairly recently, there has been limited focus on developing an accompanying medical device, such as a prefilled syringe or auto-injector, to enable easy and more efficient delivery. For the last several years, and looking forward, where there may be little to distinguish biologics medicines with relatively similar efficacy profiles, the biotechnology market is beginning to differentiate products by patient-focused, biologic-device based combination products. As innovative as biologic-device combination products are, they can pose considerable development, regulatory, and commercialization challenges due to unique physicochemical properties and special clinical considerations (e.g., dosing volumes, frequency, co-medications, etc.) of the biologic medicine. A biologic-device combination product is a marriage between two partners with "cultural differences," so to speak. There are clear differences in the development, review, and commercialization processes of the biologic and the device. When these two cultures come together in a combination product, developers and reviewers must find ways to address the design controls and risk management processes of both the biologic and device, and knit them into a single entity with supporting product approval documentation. Moreover, digital medicine and connected health trends are pushing the boundaries of combination product development and regulations even further. Despite an admirable cooperation between industry and FDA in recent years, unique product configurations and design features have resulted in review challenges. These challenges have prompted agency reviewers to modernize consultation processes, while at the same time, promoting

  3. Flexible semi-transparent silicon (100) fabric with high-k/metal gate devices

    KAUST Repository

    Rojas, Jhonathan Prieto; Hussain, Muhammad Mustafa

    2013-01-01

    (100) wafers and then released as continuous, mechanically flexible, optically semi-transparent and high thermal budget compatible silicon fabric with devices. This is the first ever demonstration with this set of materials which allows full degree

  4. Evolution of cleared channels in neutron-irradiated pure copper as a function of tensile strain

    DEFF Research Database (Denmark)

    Edwards, D.J.; Singh, B.N.

    2004-01-01

    Tensile specimens of pure copper were neutron irradiated at similar to323 K to a displacement dose of 0.3 dpa (displacement per atom). Five irradiated specimens were tensile tested at 300 K, but four of the specimens were stopped at specific strains -just before the yield point at similar to90......% of the macroscopic yield, at 1.5% and 5% elongation, and near the ultimate tensile strength at 14.5% elongation, with the 5th specimen tested to failure (e(T) = 22%). SEM and TEM characterization of the deformed specimens revealed that the plastic strain was confined primarily to the 'cleared' channels only...

  5. Features of carrier tunneling between the silicon valence band and metal in devices based on the Al/high-K oxide/SiO_2/Si structure

    International Nuclear Information System (INIS)

    Vexler, M. I.; Grekhov, I. V.

    2016-01-01

    The features of electron tunneling from or into the silicon valence band in a metal–insulator–semiconductor system with the HfO_2(ZrO_2)/SiO_2 double-layer insulator are theoretically analyzed for different modes. It is demonstrated that the valence-band current plays a less important role in structures with HfO_2(ZrO_2)/SiO_2 than in structures containing only silicon dioxide. In the case of a very wide-gap high-K oxide ZrO_2, nonmonotonic behavior related to tunneling through the upper barrier is predicted for the valence-band–metal current component. The use of an insulator stack can offer certain advantages for some devices, including diodes, bipolar tunnel-emitter transistors, and resonant-tunneling diodes, along with the traditional use of high-K insulators in a field-effect transistor.

  6. 17 CFR 39.7 - Fraud in connection with the clearing of transactions on a derivatives clearing organization.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Fraud in connection with the clearing of transactions on a derivatives clearing organization. 39.7 Section 39.7 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION DERIVATIVES CLEARING ORGANIZATIONS § 39.7 Fraud in connection...

  7. Design and Control of a 13.2 kV/10 kVA Single-Phase Solid-State-Transformer with 1.7 kV SiC Devices

    Directory of Open Access Journals (Sweden)

    Jeong-Woo Lim

    2018-01-01

    Full Text Available This paper describes the power stage design, control, and performance evaluation of a 13.2 kV/10 kVA solid-state-transformer (SST for a power distribution system. The proposed SST consists of 10 modules where each individual module contains a unidirectional three-level power factor correction (PFC converter for the active-front-end (AFE stage and an LLC resonant converter for the isolated DC-DC stage. The operating principles of the converters are analyzed and the modulation and the control schemes for the entire module are described in detail. The DC-link voltage imbalance is also less than other SST topologies due to the low number of uncontrollable switching states. In order to simplify the control of the power stage, a modulation strategy for the AFE stage is proposed, and the modulation frequency of the LLC converter is also fixed. In addition, a compensation algorithm is suggested to eliminate the current measurement offset in the AFE stage. The proposed SST achieves the unity power factor at the input AC current regardless of the reactive or nonlinear load and a low voltage regulation at the AC output. In order to verify the effectiveness of the SST, the 13.2 kV/10 kV SST prototype is built and tested. Both the simulation and the experimental results under actual 13.2 kV line show the excellent performance of the proposed SST scheme.

  8. Reduction in adverse effects of tracking devices on waterfowl requires better measuring and reporting

    NARCIS (Netherlands)

    Lameris, T.K.; Kleyheeg, Erik

    2017-01-01

    Since the first studies in the mid-twentieth century, lightweight electronic tracking devices have been increasingly used to study waterfowl movements. With half a century of experience and growing sample sizes, it has become clear that the attachment of a tracking device can affect a bird’s

  9. A power measuring device

    International Nuclear Information System (INIS)

    As, R. van.

    1985-01-01

    As a part of the klystron test facility of the Dutch NIKHEF-K accelerator, a sensitive power measuring device has been built. The high-frequency power of a klystron is stored in a water-cooled dummy load. Using a microcomputer, the increase of the water temperature and the water flow rate are transformed to a digital indication of the klystron power. (Auth.)

  10. Tetrapropylammonium ion inhibits Na, K-ATPase by blocking a K+-translocation step

    International Nuclear Information System (INIS)

    Forbush, B. III

    1986-01-01

    Tetrapropylammonium ion (TPA) has previously been shown to inhibit the Na/K pump in human red cells in competition with K + at extracellular sites. The author investigated the action of TPA on the release of 86 Rb from the occluded state of Na, K-ATPase from dog kidney. Like K + and Rb + , TPA is found to prevent the release of one (''s'' for slower) of two tightly bound 86 Rb ions when the enzyme is phosphorylated from P/sub i/; the data are consistent with TPA binding to the K + ''f'' (faster) site with an affinity of ∼5mM. When 86 Rb is bound to the ''s'' site and unlabelled Rb + or K + to the ''f'' site by an appropriate sequence of additions, the 86 Rb can be released by addition of ATP to bring about the E 2 -E]3! conformational change and translocation. In contrast when TPA is bound to the ''f'' site there is no release of 86 Rb from the ''s'' site when ATP is added, suggesting that the conformational change is prevented by the bulky TPA molecule at the transport site. Addition of Na + (without nucleotide or P/sub i/) brings about an extremely rapid (>100s -1 ) release of 86 Rb when TPA is bound. The reason for this is not yet clear, but the effect dramatically illustrates simultaneous occupancy of binding sites by K + , TPA, and Na +

  11. A new cryogenic test facility for large superconducting devices at CERN

    CERN Document Server

    Perin, A; Serio, L; Stewart, L; Benda, V; Bremer, J; Pirotte, O

    2015-01-01

    To expand CERN testing capability to superconducting devices that cannot be installed in existing test facilities because of their size and/or mass, CERN is building a new cryogenic test facility for large and heavy devices. The first devices to be tested in the facility will be the S-FRS superconducting magnets for the FAIR project that is currently under construction at the GSI Research Center in Darmstadt, Germany. The facility will include a renovated cold box with 1.2 kW at 4.5 K equivalent power with its compression system, two independent 15 kW liquid nitrogen precooling and warm-up units, as well as a dedicated cryogenic distribution system providing cooling power to three independent test benches. The article presents the main input parameters and constraints used to define the cryogenic system and its infrastructure. The chosen layout and configuration of the facility is presented and the characteristics of the main components are described.

  12. Thermal and Electrical Conductivity Measurements of CDA 510 Phosphor Bronze

    Science.gov (United States)

    Tuttle, James E.; Canavan, Edgar; DiPirro, Michael

    2009-01-01

    Many cryogenic systems use electrical cables containing phosphor bronze wire. While phosphor bronze's electrical and thermal conductivity values have been published, there is significant variation among different phosphor bronze formulations. The James Webb Space Telescope (JWST) will use several phosphor bronze wire harnesses containing a specific formulation (CDA 510, annealed temper). The heat conducted into the JWST instrument stage is dominated by these harnesses, and approximately half of the harness conductance is due to the phosphor bronze wires. Since the JWST radiators are expected to just keep the instruments at their operating temperature with limited cooling margin, it is important to know the thermal conductivity of the actual alloy being used. We describe an experiment which measured the electrical and thermal conductivity of this material between 4 and 295 Kelvin.

  13. Y2K: effects on pacemaker and implantable defibrillator programmers.

    Science.gov (United States)

    Flynn, D P; Daubert, J P; Huang, D T; Ocampo, C M; O'Gorman, E

    1999-01-01

    All permanent pacemakers and implantable defibrillators (PPM/ICDs) will continue to function as programmed without regard to the date in the year 2000 (Y2K). All manufacturers contacted reassured us that some of these devices incorporate a day/year clock in the circuitry; however, these are not involved in sensing or delivering programmed therapy. Some manufacturers' device programmers will roll over to the year 2000 without any problems at all, whereas others may have difficulty with date and time stamping on printed reports. We tested 14 different types of PPM/ICD programmers for Y2K compliance using 8 tests. Five of the 14 models passed each test and were labeled at our institution with a green "Y2K" sticker to identify them as Y2K compatible and needing no special attention after December 31, 1999. The most common test failed was the ability to roll the date forward from December 31, 1999, with the programmer power off. Organizations should consider testing and replacing noncompliant device programmers or placing a red sticker with "Y2K" crossed out on noncompliant pieces. The red sticker alerts the advanced practice nurse or physician to the need to confirm the appropriate date and time in the programmer after startup in the year 2000 and before interrogating or programming any PPM/ICD, to avoid inappropriate date and time stamping on printed reports from that programmer.

  14. Permitting product liability litigation for FDA-approved drugs and devices promotes patient safety.

    Science.gov (United States)

    Kesselheim, A S

    2010-06-01

    In 2008 and 2009, the Supreme Court reviewed the question of whether patients injured by dangerous prescription drugs or medical devices can bring tort lawsuits against pharmaceutical and device manufacturers. The Court ruled that claims against device manufacturers were preempted while claims against pharmaceutical manufacturers were not. The threat of product liability lawsuits promotes patient safety by encouraging manufacturers to take greater responsibility in providing clear warnings about known adverse effects of their products.

  15. Media Language, Clear or Obscure

    DEFF Research Database (Denmark)

    Jakobsen, Bjarne le Fevre; Ejstrup, Michael

    2015-01-01

    Abstract— Be clear, not obscure. One of the four maxims for optimal communication is that it is essential to develop proficiency in being concise and clear. The question is whether this is really a good idea in all contexts. There is some evidence to the contrary. Undoubtedly, we have many contexts...

  16. Decreasing Inappropriate Use of Mobile Devices in Urban High School Classrooms: Comparing an Antecedent Intervention With and Without the Good Behavior Game.

    Science.gov (United States)

    Hernan, Colleen J; Collins, Tai A; Morrison, Julie Q; Kroeger, Stephen D

    2018-03-01

    As the capabilities of portable technology continue to advance and become more accessible, educators express concern about the impact of the inappropriate use of mobile devices on academic engagement and learning. An alternating treatments design was used to compare the effectiveness of an antecedent (Clear Box) intervention and an interdependent group contingency (Clear Box + Good Behavior Game [GBG]) intervention to typical classroom management techniques (Control) in increasing the academic engagement and decreasing mobile device use of high school students during instruction. The results indicate an increase in academic engagement and a decrease in the inappropriate presence of mobile devices in both classrooms with the implementation of the Clear Box + GBG, as compared with the Clear Box and Control conditions. In addition, teacher and student social validity data suggested that teachers and students viewed the Clear Box + GBG intervention favorably. Discussion focuses on contributions to the current literature, implications for practice, and suggestions for future areas of research.

  17. uFLIP: Understanding the Energy Consumption of Flash Devices

    DEFF Research Database (Denmark)

    Bjørling, Matias; Bonnet, Philippe; Bouganim, Luc

    2010-01-01

    Understanding the energy consumption of flash devices is important for two reasons. First, energy is emerging as a key metric for data management systems. It is thus important to understand how we can reason about the energy consumption of flash devices beyond their approximate aggregate...... consumption (low power consumption in idle mode, average Watt consumption from the data sheets). Second, when measured at a sufficiently fine granularity, the energy consumption of a given device might complement the performance characteristics derived from its response time profile. Indeed, background work...... which is not directly observable with a response time profile appears clearly when energy is used as a metric. In this paper, we discuss the results from the {uFLIP} benchmark applied to four different {SSD} devices using both response time and energy as metric....

  18. Preparation of PZT/YBCO/YAlO heterostructure thin films by KrF excimer laser ablation

    International Nuclear Information System (INIS)

    Ebihara, Kenji; Kurogi, Hiromitsu; Yamagata, Yukihiko; Ikegami, Tomoaki; Grishin, A.M.

    1998-01-01

    The perovskite oxide YBa 2 Cu 3 O 7-x (YBCO) and Pb(Zr x Ti 1-x )O 3 (PZT) thin films have been deposited for superconducting-ferroelectric devices. KrF excimer laser ablation technique was used at the deposition conditions of 200--600 mTorr O 2 , 2-3J/cm 2 and 5--10 Hz operation frequency. Heterostructures of PZT-YBCO-YAlO 3 :Nd show the zero resistivity critical temperature of 82 K and excellent ferroelectric properties of remnant polarization 32 microC/cm 2 , coercive force of 80 kV/cm and dielectric constant 800. Cycling fatigue characteristics and leakage current are also discussed

  19. Non-aqueous energy storage devices using graphene nanosheets synthesized by green route

    Directory of Open Access Journals (Sweden)

    Dattakumar Mhamane

    2013-04-01

    Full Text Available In this paper we report the use of triethylene glycol reduced graphene oxide (TRGO as an electrode material for non-aqueous energy storage devices such as supercapacitors and Li-ion batteries. TRGO based non–aqueous symmetric supercapacitor is constructed and shown to deliver maximum energy and power densities of 60.4 Wh kg–1 and 0.15 kW kg–1, respectively. More importantly, symmetric supercapacitor shows an extraordinary cycleability (5000 cycles with over 80% of capacitance retention. In addition, Li-storage properties of TRGO are also evaluated in half-cell configuration (Li/TRGO and shown to deliver a reversible capacity of ∼705 mAh g–1 with good cycleability at constant current density of 37 mA g–1. This result clearly suggests that green-synthesized graphene can be effectively used as a prospective electrode material for non-aqueous energy storage systems such as Li-ion batteries and supercapacitors.

  20. SNOW CLEARING SERVICE WINTER 2001-2002

    CERN Multimedia

    ST-HM Group; Tel. 72202

    2001-01-01

    As usual at this time of the year, the snowing clearing service, which comes under the control of the Transport Group (ST-HM), is preparing for the start of snow-clearing operations (timetable, stand-by service, personnel responsible for driving vehicles and machines, preparation of useful and necessary equipment, work instructions, etc.) in collaboration with the Cleaning Service (ST-TFM) and the Fire Brigade (TIS-FB). The main difficulty for the snow-clearing service is the car parks, which cannot be properly cleared because of the presence of CERN and private vehicles parked there overnight in different parts of the parking areas. The ST-HM Transport Group would therefore like to invite you to park vehicles together in order to facilitate the access of the snow ploughs, thus allowing the car parks to be cleared more efficiently before the personnel arrives for work in the mornings.

  1. NATO Advanced Study Institute on Nondestructive Evaluation of Semiconductor Materials and Devices

    CERN Document Server

    1979-01-01

    From September 19-29, a NATO Advanced Study Institute on Non­ destructive Evaluation of Semiconductor Materials and Devices was held at the Villa Tuscolano in Frascati, Italy. A total of 80 attendees and lecturers participated in the program which covered many of the important topics in this field. The subject matter was divided to emphasize the following different types of problems: electrical measurements; acoustic measurements; scanning techniques; optical methods; backscatter methods; x-ray observations; accele­ rated life tests. It would be difficult to give a full discussion of such an Institute without going through the major points of each speaker. Clearly this is the proper task of the eventual readers of these Proceedings. Instead, it would be preferable to stress some general issues. What came through very clearly is that the measurements of the basic scientists in materials and device phenomena are of sub­ stantial immediate concern to the device technologies and end users.

  2. Primary clear cell sarcoma of bone

    International Nuclear Information System (INIS)

    Choi, J.H.; Gu, M.J.; Kim, M.J.; Bae, Y.K.; Choi, W.H.; Shin, D.S.; Cho, K.H.

    2003-01-01

    Clear cell sarcoma is a rare soft tissue sarcoma of young adults with melanocytic differentiation. It occurs predominantly in the soft tissue of extremities, typically involving tendons and aponeuroses. Primary clear cell sarcoma of bone is extremely rare. We report a case of primary clear cell sarcoma of the right first metatarsal in a 48-year-old woman and provide a literature review of the entity. (orig.)

  3. Study of device of electron-ion treatment of mother baking yeasts

    International Nuclear Information System (INIS)

    Ostapenkov, A.M.; Merinov, N.S.; Nazarov, V.N.; Balan, E.L.

    1980-01-01

    Devices for electron- ion treatment of mother baking yeasts are considered and classified by the way of aerions removal from the ionization zone: the first ones - by means of the electric field, the other - by air directed flux. Devices of the first type require high voltage - 20-60 kV. Electrodynamic ion generator has been applied as a device of the second type; considered is its construction, principal of operation, given are diagrams of ion flux dependence. The methods of process calculations in the generator and experimental results are presented. The main advantage of the generator of the second type is operation at low (3-5 kV) voltages. It is shown, that the yeast growth module can achieve 36% at essential increase of biomass when using these yeasts as sowing. The device can be used for biostimulation and antisepting of food raw materials

  4. Robust Control of Wide Bandgap Power Electronics Device Enabled Smart Grid

    Science.gov (United States)

    Yao, Tong

    In recent years, wide bandgap (WBG) devices enable power converters with higher power density and higher efficiency. On the other hand, smart grid technologies are getting mature due to new battery technology and computer technology. In the near future, the two technologies will form the next generation of smart grid enabled by WBG devices. This dissertation deals with two applications: silicon carbide (SiC) device used for medium voltage level interface (7.2 kV to 240 V) and gallium nitride (GaN) device used for low voltage level interface (240 V/120 V). A 20 kW solid state transformer (SST) is designed with 6 kHz switching frequency SiC rectifier. Then three robust control design methods are proposed for each of its smart grid operation modes. In grid connected mode, a new LCL filter design method is proposed considering grid voltage THD, grid current THD and current regulation loop robust stability with respect to the grid impedance change. In grid islanded mode, micro synthesis method combined with variable structure control is used to design a robust controller for grid voltage regulation. For grid emergency mode, multivariable controller designed using Hinfinity synthesis method is proposed for accurate power sharing. Controller-hardware-in-the-loop (CHIL) testbed considering 7-SST system is setup with Real Time Digital Simulator (RTDS). The real TMS320F28335 DSP and Spartan 6 FPGA control board is used to interface a switching model SST in RTDS. And the proposed control methods are tested. For low voltage level application, a 3.3 kW smart grid hardware is built with 3 GaN inverters. The inverters are designed with the GaN device characterized using the proposed multi-function double pulse tester. The inverter is controlled by onboard TMS320F28379D dual core DSP with 200 kHz sampling frequency. Each inverter is tested to process 2.2 kW power with overall efficiency of 96.5 % at room temperature. The smart grid monitor system and fault interrupt devices (FID

  5. MODIS Collection 6 Clear Sky Restoral (CSR): Filtering Cloud Mast 'Not Clear' Pixels

    Science.gov (United States)

    Meyer, Kerry G.; Platnick, Steven Edward; Wind, Galina; Riedi, Jerome

    2014-01-01

    Correctly identifying cloudy pixels appropriate for the MOD06 cloud optical and microphysical property retrievals is accomplished in large part using results from the MOD35 1km cloud mask tests (note there are also two 250m subpixel cloud mask tests that can convert the 1km cloudy designations to clear sky). However, because MOD35 is by design clear sky conservative (i.e., it identifies "not clear" pixels), certain situations exist in which pixels identified by MOD35 as "cloudy" are nevertheless likely to be poor retrieval candidates. For instance, near the edge of clouds or within broken cloud fields, a given 1km MODIS field of view (FOV) may in fact only be partially cloudy. This can be problematic for the MOD06 retrievals because in these cases the assumptions of a completely overcast homogenous cloudy FOV and 1-dimensional plane-parallel radiative transfer no longer hold, and subsequent retrievals will be of low confidence. Furthermore, some pixels may be identified by MOD35 as "cloudy" for reasons other than the presence of clouds, such as scenes with thick smoke or lofted dust, and should therefore not be retrieved as clouds. With such situations in mind, a Clear Sky Restoral (CSR) algorithm was introduced in C5 that attempts to identify pixels expected to be poor retrieval candidates. Table 1 provides SDS locations for CSR and partly cloudy (PCL) pixels.

  6. Characterization and quality control of avalanche photodiode arrays for the Clear-PEM detector modules

    International Nuclear Information System (INIS)

    Abreu, Conceicao; Amaral, Pedro; Carrico, Bruno; Ferreira, Miguel; Luyten, Joan; Moura, Rui; Ortigao, Catarina; Rato, Pedro; Varela, Joao

    2007-01-01

    Clear-PEM is a Positron Emission Mammography (PEM) prototype being developed in the framework of the Crystal Clear Collaboration at CERN. This device is a dedicated PET camera for mammography, based on LYSO:Ce scintillator crystals, Avalanche PhotoDiodes (APD) and a fast, low-noise electronics readout system, designed to examine both the breast and the axillary lymph node areas, and aiming at the detection of tumors down to 2 mm in diameter. The prototype has two planar detector heads, each composed of 96 detector modules. The Clear-PEM detector module is composed of a matrix of 32 identical 2x2x20 mm 3 LYSO:Ce crystals read at both ends by Hamamatsu S8550 APD arrays (4x8) for Depth-of-Interaction (DoI) capability. The APD arrays were characterized by the measurement of gain and dark current as a function of bias voltage, under controlled temperature conditions. Two independent setups were used. The full set of 398 APD arrays followed a well-defined quality control (QC) protocol, aiming at the rejection of arrays not complying within defined specifications. From a total of 398 arrays, only 2 (0.5%) were rejected, reassuring the trust in these detectors for prototype assembly and future developments

  7. Image guided placement of temporary anchorage devices for tooth movement

    Energy Technology Data Exchange (ETDEWEB)

    Bahl-Palomo, L.; Bissada, N. [Case Western Reserve Univ. School of Dental Medicine, Dept. of Periodontics, Cleveland, OH (United States); Palomo, J.M.; Hans, M.G. [Case Western Reserve Univ. School of Dental Medicine, Dept. of Orthodontics, Cleveland, OH (United States)

    2007-06-15

    The aim of this project is to develop an image guided protocol for placement of a temporary anchorage device without surgically reflecting a mucoperiosteal flap. Eighteen orthodontic cases were selected for skeletal anchorage from the department of orthodontics at Case University. CBCT images of the subjects were taken using the Hitachi CB MercuRay system set at 15 mA, 120 kVp. CBCT images evaluated the ideal location for TAD placement in three dimensions. Horizontal and vertical linear measurements were taken from fixed dental landmarks to clearly define the location for placement. Transverse slices were used to evaluate the thickness of the buccal plate. Using the transverse view, the angle of insertion was determined such that the maximum buccal plate surface area would contact the screw. TADs were placed in the optimum location, with the most appropriate angle of insertion using a closed approach and with minimal local anesthesia and without flap elevation. Results: All TADs were placed without anatomic encroachment and enabled fixed orthodontic anchorage. (orig.)

  8. Image guided placement of temporary anchorage devices for tooth movement

    International Nuclear Information System (INIS)

    Bahl-Palomo, L.; Bissada, N.; Palomo, J.M.; Hans, M.G.

    2007-01-01

    The aim of this project is to develop an image guided protocol for placement of a temporary anchorage device without surgically reflecting a mucoperiosteal flap. Eighteen orthodontic cases were selected for skeletal anchorage from the department of orthodontics at Case University. CBCT images of the subjects were taken using the Hitachi CB MercuRay system set at 15 mA, 120 kVp. CBCT images evaluated the ideal location for TAD placement in three dimensions. Horizontal and vertical linear measurements were taken from fixed dental landmarks to clearly define the location for placement. Transverse slices were used to evaluate the thickness of the buccal plate. Using the transverse view, the angle of insertion was determined such that the maximum buccal plate surface area would contact the screw. TADs were placed in the optimum location, with the most appropriate angle of insertion using a closed approach and with minimal local anesthesia and without flap elevation. Results: All TADs were placed without anatomic encroachment and enabled fixed orthodontic anchorage. (orig.)

  9. 21 CFR 510.106 - Labeling of antibiotic and antibiotic-containing drugs intended for use in milk-producing animals.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Labeling of antibiotic and antibiotic-containing... ANIMAL DRUGS Specific Administrative Rulings and Decisions § 510.106 Labeling of antibiotic and antibiotic-containing drugs intended for use in milk-producing animals. Whenever the labeling of an...

  10. A manufacturer's perspective: Hewlett Packard Y2K action plan.

    Science.gov (United States)

    Rapp, W N

    1999-01-01

    Medical device manufacturers must ensure that their devices are safe and effective including investigating issues involved with the century rollover. Manufacturers must begin early to evaluate their products in order to allow time to correct and distribute these product corrections and communicate to their customers so they can prepare for the Y2K event.

  11. Hairy Root Induction on Justicia gendarussa by Various Density of Agrobacterium rhizogenes strain LB 510

    Directory of Open Access Journals (Sweden)

    Dwi Kusuma Wahyuni

    2017-04-01

    Full Text Available Gandarusa (Justicia gendarussa Burm.f. is an Indonesian medicinal plant that has many benefits as drug and male contracetive. For industrial needs, Gandarusa must be  available in large quantity. Hairy root culture is one of methode to produce phytochemistry compound. The objective of the study was to examine the effect of various density of Agrobacterium rhizogenes strain LB510 on hairy roots induction of gandarusa (Justicia gendarussa Burm.f. leaf plant. Leaf explants were inoculated in MS liquid medium with various density of OD600 = 0.1; 0.2; 0.3; 0.4; and 0.5. Explants were co-cultivated for 2 days on MS solid medium without any hormone then sub-cultured on MS solid medium containing antibiotic cefotaxim 300 ppm, in dark condition. The data were analyzed descriptively and statistically. The results showed that various density of Agrobacterium rhizogenes strain LB510 was affected the lenght of hairy roots induction of J. gendarussa Burm.f., but these was not effected toward lenght formation time and number of hairy root. The treatment of OD600 0.2 was the best treatment for hairy root induction on Justicia gendarussa Burm. f. This data could be used for optimized the quality of methode of hairy root induction. 

  12. Analysis of B{yields}K{sup *}{sub J}({yields}K{pi}){mu}{sup +}{mu}{sup -} in the higher kaon resonance region

    Energy Technology Data Exchange (ETDEWEB)

    Lue, Cai-Dian [Institute of High Energy Physics, Beijing, BJ (China); Wang, Wei [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2011-11-15

    We study the resonant contributions in the process anti B{sup 0} {yields} K{sup -} {pi}{sup +}{mu}{sup +}{mu}{sup -} with the K{sup -}{pi}{sup +} invariant mass square m{sup 2}{sub K{pi}} element of [1, 5] GeV{sup 2}. Width effects of the involved strange mesons, K{sup *}(1410), K{sup *}{sub 0}(1430), K{sup *}{sub 2}(1430), K{sup *}(1680), K{sup *}{sub 3}(1780) and K{sup *}{sub 4}(2045), are incorporated. In terms of the helicity amplitudes, we derive a compact form for the full angular distributions, through which the branching ratios, forward-backward asymmetries and polarizations are attained. We propose that the uncertainties in the B {yields} K{sup *}{sub J} form factors can be pinned down by the measurements of a set of SU(3)-related processes. Using results from the large energy limit, we derive the dependence of branching fractions on the m{sub K{pi}}, and find that the K{sup *}{sub 2} resonance has a clear signature, in particular, in the transverse polarizations. (orig.)

  13. An oxide-based thermoelectric generator: Transversal thermoelectric strip-device

    Science.gov (United States)

    Teichert, S.; Bochmann, A.; Reimann, T.; Schulz, T.; Dreßler, C.; Töpfer, J.

    2015-07-01

    A special design of an oxide-based transversal thermoelectric device utilizing thermoelectric oxides in combination with a ceramic multilayer technology is proposed. Metal strips within the ceramic matrix replace the tilted stack of alternating layers used in artificial anisotropic transversal thermoelectric devices. Numerical three-dimensional simulations of both device types reveal better thermoelectric performance data for the device with metal stripes. A monolithic transversal strip-device based on the material combination La1.97Sr0.03CuO4/Ag6Pd1 was prepared and electrically characterized. A maximum power output of 4.0 mW was determined at ΔT = 225 K for the monolithic device. The observed results are in remarkable agreement with three-dimensional numerical simulations utilizing the transport parameters of the two materials and the geometry data of the device.

  14. Insertion Device Upgrade Plans at the NSLS

    CERN Document Server

    Tanabe, Toshiya; Harder, David; Lehecka, Michael; Rakowsky, George; Skaritka, John

    2005-01-01

    This paper describes plans to upgrade insertion devices at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, U.S.A. The aging wiggler (W80) at X25 is being replaced by a 1 m long in-vacuum mini-gap undulator (MGU-18) optimized for a dedicated macromolecular crystallography program. A new, 1/3 m long, in-vacuum undulator (MGU-13.5), will be installed between a pair of RF cavities at X9, and will serve a new beamline dedicated for small angle x-ray scattering (SAXS). Both MGU’s will have provision for cryocooling the NdFeB hybrid arrays to 150K to raise the field and K-value and to obtain better spectral coverage. Design issues of the devices and other considerations, especially magnetic measurement methods in low temperature will be discussed.

  15. Fabrication of large diameter alumino-silicate K+ sources

    International Nuclear Information System (INIS)

    Baca, D.; Chacon-Golcher, E.; Kwan, J.W.; Wu, J.K.

    2003-01-01

    Alumino-silicate K + sources have been used in HIF experiments for many years. For example the Neutralized Transport Expt. (NTX) and the High Current Transport Expt. (HCX) are now using this type of ion source with diameters of 2.54 cm and 10 cm respectively. These sources have demonstrated ion currents of 80 mA and 700 mA, for typical HIF pulse lengths of 5-10 (micro)s. The corresponding current density is ∼ 10-15 mA/cm 2 , but much higher current density has been observed using smaller size sources. Recently we have improved our fabrication techniques and, therefore, are able to reliably produce large diameter ion sources with high quality emitter surface without defects. This note provides a detailed description of the procedures employed in the fabrication process. The variables in the processing steps affecting surface quality, such as substrate porosity, powder size distribution, coating technique on large area concave surfaces, drying, and heat firing temperature have been investigated

  16. Short-Circuit Characterization of 10 kV 10A 4H-SiC MOSFET

    DEFF Research Database (Denmark)

    Eni, Emanuel-Petre; Beczkowski, Szymon; Munk-Nielsen, Stig

    2016-01-01

    The short-circuit capability of a power device is highly relevant for converter design and fault protection. In this paper a 10kV 10A 4H-SiC MOSFET is characterized and its short circuit withstand capability is studied and analyzed at 6 kV DC-link voltage. The test setup for this study is also...... introduced as its design, especially the inductance in the switching loop, can affect the experimental results. The study aims to present insights specific to the device which are different from that of silicon (Si) based devices. During the short-circuit operation, MOSFET saturation current, ID...

  17. Development of the closed-loop Joule-Thomson cryoablation device for long area cooling

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheon Kyu; Park, Inn Yong; Yoo, Dong Gyu; Jeong, Sang Kwon [Cryogenic Engineering Laboratory, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Park Sang Woo [Konkuk University Hospital, School of Medicine, Konkuk University, Seoul (Korea, Republic of)

    2013-09-15

    Cryoablation device is a surgical instrument to produce the cooling effect to destroy detrimental biological tissue by utilizing low temperature around 110 K. Usually, this device has the concentrated cooling region, so that it is suitable for concentrated and thick target. Accordingly, it is hard to apply this device for the target which is distributed and thin target. In this study, the design procedure of a closed-loop cryoablation device with multiple J-T expansion part is developed for the treatment of incompetent of great saphenous vein. The developed cyoablation device is designed with the analysis of 1-dimensional (1-D) bio-heat equation. The energy balance is considered to determine the minimum mass flow rate of refrigerant for consecutive flow boiling to develop the uniform cooling temperature. Azeotropic mixed refrigerant R410A and zeotropic mixed refrigerant (MR) of R22 (CHClF{sub 2}) and R23 (CHF{sub 3}) are utilized as operating fluids of the developed cryoablation device to form the sufficient temperature and to verify the quality of the inside of cryoablation probe. The experimental results of R410A and the zeotropic MR show the temperature non-uniformity over the range are 244.8K±2.7K and 239.8K±4.7K respectively. The experimental results demonstrate that the probe experiences the consecutive flow boiling over the target range of 200 mm.

  18. Structural distortions in 5-10 nm silver nanoparticles under high pressure

    Energy Technology Data Exchange (ETDEWEB)

    Koski, Kristie J.; Kamp, Noelle M.; Kunz, Martin; Knight, Jason K.; Alivisatos, A.P.; Smith, R.K.

    2008-10-13

    We present experimental evidence that silver nanoparticles in the size range of 5-10 nm undergo a reversible structural transformation under hydrostatic pressures up to 10 GPa. We have used x-ray diffraction with a synchrotron light source to investigate pressure-dependent and size-dependent trends in the crystal structure of silver nanoparticles in a hydrostatic medium compressed in a diamond-anvil cell. Results suggest a reversible linear pressure-dependent rhombohedral distortion which has not been previously observed in bulk silver. We propose a mechanism for this transition that considers the bond-length distribution in idealized multiply twinned icosahedral particles. To further support this hypothesis, we also show that similar measurements of single-crystal platinum nanoparticles reveal no such distortions.

  19. Solution-processed flexible NiO resistive random access memory device

    Science.gov (United States)

    Kim, Soo-Jung; Lee, Heon; Hong, Sung-Hoon

    2018-04-01

    Non-volatile memories (NVMs) using nanocrystals (NCs) as active materials can be applied to soft electronic devices requiring a low-temperature process because NCs do not require a heat treatment process for crystallization. In addition, memory devices can be implemented simply by using a patterning technique using a solution process. In this study, a flexible NiO ReRAM device was fabricated using a simple NC patterning method that controls the capillary force and dewetting of a NiO NC solution at low temperature. The switching behavior of a NiO NC based memory was clearly observed by conductive atomic force microscopy (c-AFM).

  20. Selective Distance-Based K+ Quantification on Paper-Based Microfluidics.

    Science.gov (United States)

    Gerold, Chase T; Bakker, Eric; Henry, Charles S

    2018-04-03

    In this study, paper-based microfluidic devices (μPADs) capable of K + quantification in aqueous samples, as well as in human serum, using both colorimetric and distance-based methods are described. A lipophilic phase containing potassium ionophore I (valinomycin) was utilized to achieve highly selective quantification of K + in the presence of Na + , Li + , and Mg 2+ ions. Successful addition of a suspended lipophilic phase to a wax printed paper-based device is described and offers a solution to current approaches that rely on organic solvents, which damage wax barriers. The approach provides an avenue for future alkali/alkaline quantification utilizing μPADs. Colorimetric spot tests allowed for K + quantification from 0.1-5.0 mM using only 3.00 μL of sample solution. Selective distance-based quantification required small sample volumes (6.00 μL) and gave responses sensitive enough to distinguish between 1.0 and 2.5 mM of sample K + . μPADs using distance-based methods were also capable of differentiating between 4.3 and 6.9 mM K + in human serum samples. Distance-based methods required no digital analysis, electronic hardware, or pumps; any steps required for quantification could be carried out using the naked eye.

  1. K/sub infinity/-meter concept verified via subcritical-critical TRIGA experiments

    International Nuclear Information System (INIS)

    Ocampo Mansilla, H.

    1983-01-01

    This work presents a technique for building a device to measure the k/sub infinity/ of a spent nuclear fuel assembly discharged from the core of a nuclear power plant. The device, called a k/sub infinity/-meter, consists of a cross-shaped subcritical assembly, two artificial neutron sources, and two separate neutron counting systems. The central position of the subcritical assembly is used to measure k/sub infinity/ of the spent fuel assembly. The initial subcritical assembly is calibrated to determine its k/sub eff/ and verify the assigned k/sub infinity/ of a selected fuel assembly placed in the central position. Count rates are taken with the fuel assembly of known k/sub infinity/'s placed in the central position and then repeated with a fuel assembly of unknown k/sub infinity/ placed in the central position. The count rate ratio of the unknown fuel assembly to the known fuel assembly is used to determine the k/sub infinity/ of the unknown fuel assembly. The k/sub infinity/ of the unknown fuel assembly is represented as a polynomial function of the count rate ratios. The coefficients of the polynomial equation are determined using the neutronic codes LEOPARD and EXTERMINATOR-II. The analytical approach has been validated by performing several subcritical/critical experiments, using the Penn State Breazeale TRIGA Reactor (PSBR), and comparing the experimental results with the calculations

  2. RHIZOME YIELD OF TEMULAWAK (Curcuma xanthorrhiza Roxb. AT N, P, K VARIOUS LEVEL AND N, K COMBINATION

    Directory of Open Access Journals (Sweden)

    Ellis Nihayati

    2014-02-01

    Full Text Available The role of N, P and K on temulawak have not been clear enough to explain the need in temulawak rhizome in order to get high yield. The experiment was conducted in a screen house in Malang East Java with an altitude of 500 m asl. from Desember 2010 - August 2011. There were 4 experiments in series, consisting of N, P, K various level and N,K alone and combination on the growth and quantity of rhizome arranged in randomized block design comprising 7 levels of fertilizer per plant with 3 replications. The treatments of urea (N, SP36 (P consisted of 0, 1,25, 2,5, 3,75, 5, 6,25 and 7.5 g. The KCl (K comprised 0, 1,5, 3, 4,5, 6, 7,5 and 9 g. The N, K alone and combination treatments consisted of (No fertilizer, N, K, NK g /plant. The results of this research were N, P, K optimum dose of each N 6.25 g N / plant P2O5/tan P 6.25 g, K 7.5 g K2O / plant increased temulawak rhizome dry weight. Combination 4.5 g N + 2.8 g K / plant could increase temulawak rhizome dry weight by 33% compared to the addition of N and 220% when compared to the addition of a single K harvesting age 6 months.

  3. Pneumatic devices in isotope technology. Pt. 1

    International Nuclear Information System (INIS)

    Egri, B.; Csoeke, A.

    1974-01-01

    A detailed survey has been given about the following pneumatic devices used in the isotope technology: working cylinders, membrane motors, valves, detectors, hydropneumatic units. The characteristics of the units of various control systems have been described in tables. (K.A.)

  4. A Mixed-Method Study of Mobile Devices and Student Self-Directed Learning and Achievement during a Middle School STEM Activity

    Science.gov (United States)

    Bartholomew, Scott

    2016-01-01

    With the increasingly ubiquitous nature of mobile devices among K-12 students, many argue for and against the inclusion of these devices in K-12 classrooms. Arguments in favor cite instant access to information and collaboration with others as positive affordances made possible through mobile devices. Self-directed learning, a process where…

  5. Method and device for bio-impedance measurement with hard-tissue applications

    International Nuclear Information System (INIS)

    Guimerà, A; Calderón, E; Los, P; Christie, A M

    2008-01-01

    Bio-impedance measurements can be used to detect and monitor several properties of living hard-tissues, some of which include bone mineral density, bone fracture healing or dental caries detection. In this paper a simple method and hardware architecture for hard tissue bio-impedance measurement is proposed. The key design aspects of such architecture are discussed and a commercial handheld ac impedance device is presented that is fully certified to international medical standards. It includes a 4-channel multiplexer and is capable of measuring impedances from 10 kΩ to 10 MΩ across a frequency range of 100 Hz to 100 kHz with a maximum error of 5%. The device incorporates several user interface methods and a Bluetooth link for bi-directional wireless data transfer. Low-power design techniques have been implemented, ensuring the device exceeds 8 h of continuous use. Finally, bench test results using dummy cells consisting of parallel connected resistors and capacitors, from 10 kΩ to 10 MΩ and from 20 pF to 100 pF, are discussed

  6. Method and device for bio-impedance measurement with hard-tissue applications.

    Science.gov (United States)

    Guimerà, A; Calderón, E; Los, P; Christie, A M

    2008-06-01

    Bio-impedance measurements can be used to detect and monitor several properties of living hard-tissues, some of which include bone mineral density, bone fracture healing or dental caries detection. In this paper a simple method and hardware architecture for hard tissue bio-impedance measurement is proposed. The key design aspects of such architecture are discussed and a commercial handheld ac impedance device is presented that is fully certified to international medical standards. It includes a 4-channel multiplexer and is capable of measuring impedances from 10 kOmega to 10 MOmega across a frequency range of 100 Hz to 100 kHz with a maximum error of 5%. The device incorporates several user interface methods and a Bluetooth link for bi-directional wireless data transfer. Low-power design techniques have been implemented, ensuring the device exceeds 8 h of continuous use. Finally, bench test results using dummy cells consisting of parallel connected resistors and capacitors, from 10 kOmega to 10 MOmega and from 20 pF to 100 pF, are discussed.

  7. Glow discharging device

    International Nuclear Information System (INIS)

    Maeno, Katsuki; Kawasaki, Kozo; Hiratsuka, Hajime; Kawashima, Shuichi.

    1989-01-01

    In a thermonuclear device, etc. impurities adsorbed to inner walls of a vacuum vessel by glow discharge are released to clean the vacuum vessel for preventing intrusion of the impurities into plasmas. The object of the present invention is to minimize the capacity of a power source equipment for the glow discharge device to the least extent. That is, a stabilization resistance is connected in series between each of a plurality of anodes which are inserted and arranged at the inside of a vacuum vessel as a cathode and a power source respectively. The resistance value R is selected so as to satisfy the relation: R < (Vi - Vm)/Ii, in which Vi: glow discharge starting voltage, Vm: glow discharge keeping voltage, Ii: glow discharge starting current. Accordingly, if a voltage is applied from a power source to a plurality of anodes, scattering of electric discharge between the anodes can be suppressed and the effect of voltage drop during discharge by the stabilization resistance can be eliminated. As a result, it is possible to provide an economically advantageous glow discharge device with the capacity for the power source facility being to the least extent. (K.M.)

  8. 21 CFR 314.510 - Approval based on a surrogate endpoint or on an effect on a clinical endpoint other than survival...

    Science.gov (United States)

    2010-04-01

    ... Serious or Life-Threatening Illnesses § 314.510 Approval based on a surrogate endpoint or on an effect on... well-controlled. The applicant shall carry out any such studies with due diligence. ...

  9. Radiation effects on custom MOS devices

    International Nuclear Information System (INIS)

    Harris, R.

    1999-05-01

    This Thesis consists of four chapters: The first is primarily for background information on the effects of radiation on MOS devices and the theory of wafer bonding; the second gives a full discussion of all practical work carried out for manufacture of Field Effect test Capacitors, the third discusses manufacture of vacuum insulator Field Effect Transistors (FET's) and the fourth discusses the testing of these devices. Using a thermally bonded field effect capacitor structure, a vacuum dielectric was studied for use in high radiation environments with a view to manufacturing a CMOS compatible, micro machined transistor. Results are given in the form of high frequency C-V curves before and after a 120 kGy(Si), 12 MRad(Si), dose from a Co 60 source showing a 1 Volt shift. The work is then extended to the design and manufacture of a micro machined, under-etch technique, Field Effect Transistor for use in high radiation areas. Results are shown for Threshold, Subthreshold and Transfer characteristics before and after irradiation up to a total dose of 100kGy or 10MRad. The conclusion from this work is that it should be possible to commercially manufacture practical vacuum dielectric field effect transistors which are radiation hard to at least 120 kGy(Si). (author)

  10. Recent development status of compact 2 K GM cryocoolers

    Science.gov (United States)

    Bao, Q.; Xu, M. Y.; Tsuchiya, A.; Li, R.

    2015-12-01

    To meet the growing demand for a compact cooling solution for superconducting electronic devices, we developed a two-stage 2 K GM cryocooler and a cryostat system, which can reach 46.3 K / 2.2 K on the first and second stages under no-load conditions. Nevertheless, with several innovative technologies applied, the total length of the expander cylinder is reduced to under 70% of the smallest conventional 4 K GM cryocooler. In this paper we will present the design method, including material selection and structure design with detailed explanation, which has been confirmed by both simulation and experiment.

  11. 1000 Hours of Testing Completed on 10-kW Hall Thruster

    Science.gov (United States)

    Mason, Lee S.

    2001-01-01

    Between the months of April and August 2000, a 10-kW Hall effect thruster, designated T- 220, was subjected to a 1000-hr life test evaluation. Hall effect thrusters are propulsion devices that electrostatically accelerate xenon ions to produce thrust. Hall effect propulsion has been in development for many years, and low-power devices (1.35 kW) have been used in space for satellite orbit maintenance. The T-220, shown in the photo, produces sufficient thrust to enable efficient orbital transfers, saving hundreds of kilograms in propellant over conventional chemical propulsion systems. This test is the longest operation ever achieved on a high-power Hall thruster (greater than 4.5 kW) and is a key milestone leading to the use of this technology for future NASA, commercial, and military missions.

  12. Snow-clearing operations

    CERN Multimedia

    EN Department

    2010-01-01

    To facilitate snow clearing operations, which commence at 4.30 in the morning, all drivers of CERN cars are kindly requested to park them together in groups. This will help us greatly assist us in our work. Thank-you for your help. Transport Group / EN-HE Tel. 72202

  13. Laryngeal Sensation Before and After Clearing Behaviors

    Science.gov (United States)

    Bonilha, Heather Shaw; Gerlach, Terri Treman; Sutton, Lori Ellen; Dawson, Amy Elizabeth; Nietert, Paul J

    2013-01-01

    Purpose People frequently present to voice clinics with complaints of irritating laryngeal sensations. Clinicians attempt to reduce the irritating sensations and their common sequela, coughing and throat clearing, by advocating for techniques that remove the irritation with less harm to the vocal fold tissue. Despite the prevalence of patients with these complaints, it is not known if the less harmful techniques recommended by clinicians are effective at clearing irritating laryngeal sensations or that irritating laryngeal sensations are, in fact, more frequent in people with voice disorders than people without voice disorders. Method Assessments of participant reported laryngeal sensation, pre- and post- clearing task, were obtained from 22 people with and 24 people without a voice disorder. Six clearing tasks were used to preliminarily evaluate the differing effects of tasks believed to be deleterious and ameliorative. Results People with and without voice disorders reported pre-clear laryngeal sensation at a similar rate. Post-clear sensation was less likely to be completely or partially removed in people with voice disorders than in the non-voice disordered group. Hard throat clear and swallow with water were the most effective techniques at removing laryngeal sensation. Conclusions The findings provide initial evidence for some of the clinical practices common to treating patients with voice disorders and chronic clearing such as advocating for swallowing a sip of water as a replacement behavior instead of coughing or throat clearing. However, the findings raise questions about other practices such as associating irritating laryngeal sensation with a voice disorder. PMID:22717491

  14. A Novel Saccharomyces cerevisiae Killer Strain Secreting the X Factor Related to Killer Activity and Inhibition of S. cerevisiae K1, K2 and K28 Killer Toxins.

    Science.gov (United States)

    Melvydas, Vytautas; Bružauskaitė, Ieva; Gedminienė, Genovaitė; Šiekštelė, Rimantas

    2016-09-01

    It was determined that Kx strains secrete an X factor which can inhibit all known Saccharomyces cerevisiae killer toxins (K1, K2, K28) and some toxins of other yeast species-the phenomenon not yet described in the scientific literature. It was shown that Kx type yeast strains posess a killer phenotype producing small but clear lysis zones not only on the sensitive strain α'1 but also on the lawn of S. cerevisiae K1, K2 and K28 type killer strains at temperatures between 20 and 30 °C. The pH at which killer/antikiller effect of Kx strain reaches its maximum is about 5.0-5.2. The Kx yeast were identified as to belong to S. cerevisiae species. Another newly identified S. cerevisiae killer strain N1 has killer activity but shows no antikilller properties against standard K1, K2 and K28 killer toxins. The genetic basis for Kx killer/antikiller phenotype was associated with the presence of M-dsRNA which is bigger than M-dsRNA of standard S. cerevisiae K1, K2, K28 type killer strains. Killer and antikiller features should be encoded by dsRNA. The phenomenon of antikiller (inhibition) properties was observed against some killer toxins of other yeast species. The molecular weight of newly identified killer toxins which produces Kx type strains might be about 45 kDa.

  15. Hot spot dynamics in carbon nanotube array devices.

    Science.gov (United States)

    Engel, Michael; Steiner, Mathias; Seo, Jung-Woo T; Hersam, Mark C; Avouris, Phaedon

    2015-03-11

    We report on the dynamics of spatial temperature distributions in aligned semiconducting carbon nanotube array devices with submicrometer channel lengths. By using high-resolution optical microscopy in combination with electrical transport measurements, we observe under steady state bias conditions the emergence of time-variable, local temperature maxima with dimensions below 300 nm, and temperatures above 400 K. On the basis of time domain cross-correlation analysis, we investigate how the intensity fluctuations of the thermal radiation patterns are correlated with the overall device current. The analysis reveals the interdependence of electrical current fluctuations and time-variable hot spot formation that limits the overall device performance and, ultimately, may cause device degradation. The findings have implications for the future development of carbon nanotube-based technologies.

  16. Field demonstration of a portable, X-ray, K-edge heavy-metal detector

    International Nuclear Information System (INIS)

    Jensen, T.; Aljundi, T.; Whitmore, C.; Zhong, H.; Gray, J.N.

    1997-01-01

    Under the Characterization, Monitoring, and Sensor Technology Crosscutting Program, the authors have designed and built a K-edge heavy metal detector that measures the level of heavy metal contamination inside closed containers in a nondestructive, non-invasive way. The device employs a volumetric technique that takes advantage of the X-ray absorption characteristics of heavy elements, and is most suitable for characterization of contamination inside pipes, processing equipment, closed containers, and soil samples. The K-edge detector is a fast, efficient, and cost-effective in situ characterization tool. More importantly, this device will enhance personnel safety while characterizing radioactive and toxic waste. The prototype K-edge system was operated at the Materials and Chemistry Laboratory User Facility at the Oak Ridge K-25 Site during February 1997. Uranium contaminated pipes and valves from a UF 6 feed facility were inspected using the K-edge technique as well as a baseline nondestructive assay method. Operation of the K-edge detector was demonstrated for uranium contamination ranging from 10 to 6,000 mg/cm 2 and results from the K-edge measurements were found to agree very well with nondestructive assay measurements

  17. Investigation of capacitance characteristics in metal/high-k ...

    Indian Academy of Sciences (India)

    MS received 4 May 2016; accepted 10 January 2017; published online 21 August 2017. Abstract. Capacitance vs. ... with high-k materials is the prime technological challenge. [2]. ... reliability of MOS devices are strongly dependent on the for-.

  18. Conceptual radiation shielding design of superconducting tokamak fusion device by PHITS

    International Nuclear Information System (INIS)

    Sukegawa, Atsuhiko M.; Kawasaki, Hiromitsu; Okuno, Koichi

    2010-01-01

    A complete 3D neutron and photon transport analysis by Monte Carlo transport code system PHITS (Particle and Heavy Ion Transport code System) have been performed for superconducting tokamak fusion device such as JT-60 Super Advanced (JT-60SA). It is possible to make use of PHITS in the port streaming analysis around the devices for the tokamak fusion device, the duct streaming analysis in the building where the device is installed, and the sky shine analysis for the site boundary. The neutron transport analysis by PHITS makes it clear that the shielding performance of the superconducting tokamak fusion device with the cryostat is improved by the graphical results. From the standpoint of the port streaming and the duct streaming, it is necessary to calculate by 3D Monte Carlo code such as PHITS for the neutronics analysis of superconducting tokamak fusion device. (author)

  19. Beam acceleration in plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Antanasijevic, R.; Banjanac, R.; Dragic, A.; Maric, Z.; Stanojevic, J.; Udovicic, V. E-mail: udovicic@atom.phy.bg.ac.yu; Vukovic, J

    2001-06-01

    The proton beam emission from the small 8 kJ plasma focus device operated with the H{sub 2} filling was analyzed. Maximum energy and yield were obtained using NTD. The fast protons were registered with the energy up to 500 keV using the polycarbonate absorbers with the different thickness.

  20. Beam acceleration in plasma focus device

    International Nuclear Information System (INIS)

    Antanasijevic, R.; Banjanac, R.; Dragic, A.; Maric, Z.; Stanojevic, J.; Udovicic, V.; Vukovic, J.

    2001-01-01

    The proton beam emission from the small 8 kJ plasma focus device operated with the H 2 filling was analyzed. Maximum energy and yield were obtained using NTD. The fast protons were registered with the energy up to 500 keV using the polycarbonate absorbers with the different thickness

  1. Monitoring device for the reactor power distribution

    International Nuclear Information System (INIS)

    Uematsu, Hitoshi; Tsuiki, Makoto

    1982-01-01

    Purpose: To enable accurate monitoring for the power distribution in a short time, as well as independent detection for in-core neutron flux detectors in abnormal operation due to failures or like other causes to thereby surely provide reliable substitute values. Constitution: Counted values are inputted from a reactor core present status data detector by a power distribution calculation device to calculate the in-core neutron flux density and the power distribution based on previously stored physical models. While on the other hand, counted value from the in-core neutron detectors and the neutron flux distribution and the power distribution calculated from the power distribution calculation device are inputted from a BCF calculation device to compensate the counting errors incorporated in the counted value from the in-core neutron flux detectors and the calculation errors incorporated in the power distribution calculated in the power distribution calculation device respectively and thereby calculate the power distribution in the reactor core. Further, necessary data are inputted to the power distribution calculation device by an input/output device and the results calculated in the BCF calculation device are displayed. (Aizawa, K.)

  2. A pleural vacuum relief device for pleural drain unit use in the hyperbaric environment.

    Science.gov (United States)

    Gelsomino, Marco; Tsouras, Theo; Millar, Ian; Fock, Andrew

    2017-09-01

    When a standard water-seal pleural drain unit (PDU) is used under hyperbaric conditions there are scenarios where excessive negative intrapleural pressure (IPP) and/or fluid reflux can be induced, risking significant morbidity. We developed and tested a pleural vacuum relief (PVR) device which automatically manages these risks, whilst allowing more rapid hyperbaric pressure change rates. The custom-made PVR device consists of a one-way pressure relief valve connected in line with a sterile micro filter selected for its specific flow capacity. The PVR device is designed for connection to the patient side sampling port of a PDU system, allowing inflow of ambient air whenever negative pressure is present, creating a small, controlled air leak which prevents excessive negative pressure. The hyperbaric performance of a Pleur-Evac A-6000 intercostal drain was assessed with and without this added device by measuring simulated IPP with an electronic pressure monitor connected at the patient end of the PDU. IPP readings were taken at 10, 15, 20 and 30 cmH₂O of suction (set on the drain unit) at compression rates of 10, 30, 60, 80, 90 and 180 kPa·min⁻¹ to a pressure of 280 kPa. At any compression rate of > 10 kPa·min⁻¹, the negative IPP generated by the Pleur-Evac A-6000 alone was excessive and resulted in back flow through the PDU water seal. By adding the PVR device, the generated negative IPP remains within a clinically acceptable range, allowing compression rates of at least 30 kPa·min⁻¹ with suction settings up to -20 cmH₂O during all phases of hyperbaric treatment. The PDU PVR device we have developed works well, minimising attendant workload and automatically avoiding the excessive negative IPPs that can otherwise occur. This device should only be used with suction.

  3. Preliminary Inter-Comparison between AHI, VIIRS and MODIS Clear-Sky Ocean Radiances for Accurate SST Retrievals

    Directory of Open Access Journals (Sweden)

    Xingming Liang

    2016-03-01

    Full Text Available Clear-sky brightness temperatures (BT in five bands of the Advanced Himawari Imager (AHI; flown onboard Himawari-8 satellite centered at 3.9, 8.6, 10.4, 11.2, and 12.3 µm (denoted by IR37, IR86, IR10, IR11, and IR12, respectively are used in the NOAA Advanced Clear-Sky Processor for Oceans (ACSPO sea surface temperature (SST retrieval system. Here, AHI BTs are preliminarily evaluated for stability and consistency with the corresponding VIIRS and MODIS BTs, using the sensor observation minus model simulation (O-M biases and corresponding double differences. The objective is to ensure accurate and consistent SST products from the polar and geo sensors, and to prepare for the launch of the GOES-R satellite in 2016. All five AHI SST bands are found to be largely in-family with their polar counterparts, but biased low relative to the VIIRS and MODIS (which, in turn, were found to be stable and consistent, except for Terra IR86, which is biased high by 1.5 K. The negative biases are larger in IR37 and IR12 (up to ~−0.5 K, followed by the three remaining longwave IR bands IR86, IR10, and IR11 (from −0.3 to −0.4 K. These negative biases may be in part due to the uncertainties in AHI calibration and characterization, although uncertainties in the coefficients of the Community Radiative Transfer Model (CRTM, used to generate the “M” term may also contribute. Work is underway to add AHI analyses in the NOAA Monitoring of IR Clear-Sky Radiances over Oceans for SST (MICROS system and improve AHI BTs by collaborating with the sensor calibration and CRTM teams. The Advanced Baseline Imager (ABI analyses will be also added in MICROS when GOES-R is launched in late 2016 and the ABI IR data become available.

  4. Evaluation of pharmacokinetics, user handling, and tolerability of peginterferon alfa-2a (40 kDa delivered via a disposable autoinjector device

    Directory of Open Access Journals (Sweden)

    Varunok P

    2011-11-01

    Full Text Available Peter Varunok1, Eric Lawitz2, Kimberly L Beavers3, Gary Matusow4, Ruby Leong5, Nathalie Lambert6, Coen Bernaards7, Jonathan Solsky5, Barbara J Brennan5, Cynthia Wat8, Anne Bertasso51Gastroenterology Associates, Poughkeepsie, NY, USA; 2Alamo Medical Research, San Antonio, TX, USA; 3Asheville Gastroenterology, Asheville, NC, USA; 4Gastroenterology Group, South Jersey, NJ, USA; 5Roche, Nutley, NJ, USA; 6Roche, Basel, Switzerland; 7Roche, San Francisco, CA, USA; 8Roche, Welwyn, UKBackground: Peginterferon alfa-2a (40 kDa is currently administered using a prefilled syringe. The peginterferon alfa-2a disposable autoinjector is a new safety-engineered device designed to facilitate injection and reduce the risk of needlestick injuries. The analysis of two open-label Phase I trials evaluated the pharmacokinetics, successful administration, and tolerability of peginterferon alfa-2a when using the autoinjector. The studies were performed to support the filing and registration of the autoinjector device.Methods: In trial 1, 50 healthy adult subjects received one 180 µg dose of peginterferon alfa-2a via the autoinjector. Serial blood samples were collected predose, up to 336 hours following drug administration, and at follow-up (28 ± 3 days post-dosing for noncompartmental pharmacokinetic analysis. Trial 2 randomized 60 adult patients with chronic hepatitis C to 180 µg peginterferon alfa-2a once weekly by the autoinjector or prefilled syringe for 3 weeks followed by the alternative device (prefilled syringe or autoinjector, respectively for 3 weeks. Patients also received ribavirin. Administration by the devices was evaluated under direct observation by a study staff member and by patient subjective assessment.Results: In trial 1, following a single dose of peginterferon alfa-2a, the maximum plasma concentration was 16.1 ± 5.3 ng/mL (mean ± standard deviation, and area under the concentration time curve (0–168 hours was 1996 ± 613 ng · hour

  5. Interface Study on Amorphous Indium Gallium Zinc Oxide Thin Film Transistors Using High-k Gate Dielectric Materials

    Directory of Open Access Journals (Sweden)

    Yu-Hsien Lin

    2015-01-01

    Full Text Available We investigated amorphous indium gallium zinc oxide (a-IGZO thin film transistors (TFTs using different high-k gate dielectric materials such as silicon nitride (Si3N4 and aluminum oxide (Al2O3 at low temperature process (<300°C and compared them with low temperature silicon dioxide (SiO2. The IGZO device with high-k gate dielectric material will expect to get high gate capacitance density to induce large amount of channel carrier and generate the higher drive current. In addition, for the integrating process of integrating IGZO device, postannealing treatment is an essential process for completing the process. The chemical reaction of the high-k/IGZO interface due to heat formation in high-k/IGZO materials results in reliability issue. We also used the voltage stress for testing the reliability for the device with different high-k gate dielectric materials and explained the interface effect by charge band diagram.

  6. U. K. surface passenger transport sector. Energy consumption and policy options for conservation

    Energy Technology Data Exchange (ETDEWEB)

    Maltby, D; Monteath, I G; Lawler, K A

    1978-12-01

    Forecasts of U.K. energy consumption in this sector for four future scenarios based on different economic growth rates, energy prices, and energy conservation policies, show that by the year 2000, private transport will probably account for 76-94% of total energy consumption in surface passenger transport. A 33% increase in the average miles-per-gallon fuel consumption through technological improvements in private vehicles, conversion of private vehicles to diesel oil, additional fuel taxation equivalent to 25 or 50% fuel price increase, a 10% reduction in average car engine size (encouraged by taxation), and changes in public transport technology offer energy savings of about 20, 5-10, 6.3 or 12.5, 2-4, and 2%, respectively. There is considerable uncertainty about the outcome of these options.

  7. A Mixed-Method Study of Mobile Devices and Student Self-Directed Learning and Achievement During a Middle School STEM Activity

    OpenAIRE

    Bartholomew, Scott

    2016-01-01

    The increasingly ubiquitous nature of mobile devices among K-12 students has led many to argue for and against the inclusion of mobile devices in K-12 classrooms. Some have conjectured that access to mobile devices may enable student self-directed learning. This research used a mixed-method approach to explore the relationships between mobile devices and student achievement and self-directed learning during a Science, Technology, Engineering, & Mathematics (STEM) activity in a middle schoo...

  8. CLEARING OF ELECTRON CLOUD IN SNS

    International Nuclear Information System (INIS)

    WANG, L.; LEE, Y.Y.; RAPRIA, D.

    2004-01-01

    In this paper we describe a mechanism using the clearing electrodes to remove the electron cloud in the Spallation Neutron Source (SNS) accumulator ring, where strong multipacting could happen at median clearing fields. A similar phenomenon was reported in an experimental study at Los Alamos laboratory's Proton Synchrotron Ring (PSR). We also investigated the effectiveness of the solenoid's clearing mechanism in the SNS, which differs from the short bunch case, such as in B-factories. The titanium nitride (TiN) coating of the chamber walls was applied to reduce the secondary electron yield (SEY)

  9. More than a device: today's medical technology companies provide value through service.

    Science.gov (United States)

    McCoy, Fred

    2003-01-01

    When physicians implant cardiac rhythm management devices, they establish a long-term relationship with those devices and with the manufacturers of those devices. The therapeutic value that each device will provide to its patient is enhanced throughout the life of the device by the services that the manufacturer provides. Services are provided prior to, during and long after implantation. Services include physician and allied health professional training, quality assurance programs, therapy outreach initiatives, on site technical support during device implantation and follow-up, technical service expertise and customer service support. The costs of these services are substantial. When assessed on a per device basis, the service costs may actually exceed the costs of manufacture. Further, the costs of these services are rising. Over the past five years, the number of implanted cardiac rhythm management devices has doubled. Industry field forces have tripled in size. Clearly, industry is dedicated to providing service as a critical element in achieving excellent patient outcomes.

  10. Ethical regulation on researches at Brazil: do we need the 510 Resolution?

    Directory of Open Access Journals (Sweden)

    Carlos Adriano Silva dos Santos

    2018-02-01

    Full Text Available Since 1996, with the implementation of the 196/96 National Health Council Resolution, Brazil has risen on the world stage as an important country with regard the regulatory aspect of research with human beings. New challenges, amendments and complements lead to a new Resolution, the 466/12. Since the implementation of 196/96 through to the present day with the 466/12, some groups of researchers in Social and Human Sciences displayed dissatisfaction with the Brazilian regulatory system and they proposed a new Resolution specific to research in the field of Social and Human Sciences. Thus, Resolution 510/16 was created. This article discusses if this Resolution is necessary.

  11. SLUDGE BATCH 4 BASELINE MELT RATE FURNACE AND SLURRY-FED MELT RATE FURNACE TESTS WITH FRITS 418 AND 510 (U)

    International Nuclear Information System (INIS)

    Smith, M; Timothy Jones, T; Donald02 Miller, D

    2007-01-01

    Several Slurry-Fed Melt Rate Furnace (SMRF) tests with earlier projections of the Sludge Batch 4 (SB4) composition have been performed.1,2 The first SB4 SMRF test used Frits 418 and 320, however it was found after the test that the REDuction/OXidation (REDOX) correlation at that time did not have the proper oxidation state for manganese. Because the manganese level in the SB4 sludge was higher than previous sludge batches tested, the impact of the higher manganese oxidation state was greater. The glasses were highly oxidized and very foamy, and therefore the results were inconclusive. After resolving this REDOX issue, Frits 418, 425, and 503 were tested in the SMRF with the updated baseline SB4 projection. Based on dry-fed Melt Rate Furnace (MRF) tests and the above mentioned SMRF tests, two previous frit recommendations were made by the Savannah River National Laboratory (SRNL) for processing of SB4 in the Defense Waste Processing Facility (DWPF). The first was Frit 503 based on the June 2006 composition projections.3 The recommendation was changed to Frit 418 as a result of the October 2006 composition projections (after the Tank 40 decant was implemented as part of the preparation plan). However, the start of SB4 processing was delayed due to the control room consolidation outage and the repair of the valve box in the Tank 51 to Tank 40 transfer line. These delays resulted in changes to the projected SB4 composition. Due to the slight change in composition and based on preliminary dry-fed MRF testing, SRNL believed that Frit 510 would increase throughput in processing SB4 in DWPF. Frit 418, which was used in processing Sludge Batch 3 (SB3), was a viable candidate and available in DWPF. Therefore, it was used during the initial SB4 processing. Due to the potential for higher melt rates with Frit 510, SMRF tests with the latest SB4 composition (1298 canisters) and Frits 510 and 418 were performed at a targeted waste loading (WL) of 35%. The '1298 canisters

  12. Construction of a dog training device with high frequency and high power pulses

    International Nuclear Information System (INIS)

    Viaud Trejos, Rafael Alfonso

    2013-01-01

    An electronic device is built to produce high frequency and high power sound. The device is used in training and control of dogs. Commercial ultrasonic devices used for dog training are analyzed. The best strategies and components of the design are determined from an electronic device to produce sounds in frequency from 15kHz to 50Khz. Effectiveness tests are performed to establish the adequate design of the ultrasonic electronic device. The test results are analyzed to find opportunities of improvement in the design or construction of the device [es

  13. VCP5 VMware Certified Professional on vSphere 5 Study Guide Exam VCP-510

    CERN Document Server

    Atkinson, Brian

    2012-01-01

    The ideal study guide for candidates seeking the leading virtualization certification The VMware Certified Professional on vSphere 5 (VCP-510) is the most desired certification for virtualization professionals, and this study guide covers all the requirements. Skill in virtualization is a top priority for companies when hiring IT staff, and VMware skills are in high demand. Part of the highly acclaimed Sybex Study Guide series, this comprehensive book guides you through planning, installing, and upgrading ESXi; configuring networking, storage, and vCenter Server; deploying and managing virtual

  14. A study on the insulation coordination of 765 kV system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeong Boo; Shim, Eung Bo [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center; Lee, Yong Han; Youn, Jae Yeong; Hwang, Chi Woo; Jung, Dong Hak [Korea Electrotechnology Research Inst., Changwon (Korea, Republic of)

    1996-12-31

    Analysis of the power frequency temporary overvoltage. Analysis of switching surges - Fault imitation, closing and re closing, fault clearing. Analysis of lightning surges. Insulation design of 765 kV overhead transmission line. Insulation coordination of 765 kV gas insulated substation. Transient recovery voltage and high speed ground switch (author). 38 refs., 55 figs.

  15. Radiorespirometic assay device

    International Nuclear Information System (INIS)

    Levin, G.V.; Straat, P.A.

    1981-01-01

    A radiorespirometic assay device is described in which the presence of microorganisms in a sample is determined by placing the sample in contact with a metabolisable radioactive labelled substrate, collecting any gas evolved, exposing a photosensitive material to the gas and determining if a spot is produced on the material. A spot indicates the presence of radioactivity showing that the substrate has been metabolized by a microorganism. Bacteria may be detected in body fluids, hospital operating rooms, water, food, cosmetics and drugs. (U.K.)

  16. Steady state gamma testing of a 4K NMOS dynamic RAM

    International Nuclear Information System (INIS)

    Coleman, D.W.; Temkin, B.M.

    1976-01-01

    Samples of the Texas Instruments TMS4060JL, 4096 bit dynamic random-access memory (4K RAM) were tested in the ionizing environment of a 137 Ce source. Irradiated in an active condition, the devices were observed to fail at 1 x 10 3 rads (Si). Twenty-four hours after irradiation, 4 of the 5 devices tested were again functional. The devices were not powered and were at room temperature during the 24 hour anneal period

  17. Effect of various warm-up devices on bat velocity of intercollegiate softball players.

    Science.gov (United States)

    Szymanski, David J; Bassett, Kylie E; Beiser, Erik J; Till, Megan E; Medlin, Greg L; Beam, Jason R; Derenne, Coop

    2012-01-01

    Numerous warm-up devices are available for use by softball players while they are in the on-deck circle. It is difficult to know which warm-up device produces the greatest bat velocity (BV) in the batter's box for softball players because on-deck studies with these individuals are sparse. Because the majority of warm-up device research has been conducted with baseball players, the primary purpose of this study was to examine the effect of various warm-up devices on the BV of female intercollegiate softball players and compare the results with those of male baseball players. A secondary purpose was to evaluate 2 new commercially available resistance devices as warm-up aids. Nineteen Division I intercollegiate softball players (age = 19.8 ± 1.2 years, height = 167.0 ± 4.7 cm, body mass = 69.2 ± 8.6 kg, lean body mass = 49.6 ± 3.6 kg, % body fat = 27.9 ± 5.9) participated in a warm-up with 1 of 8 resistance devices on separate days. Each of the 8 testing sessions had players perform a standardized dynamic warm-up, 3 maximal dry swings mimicking their normal game swing with the assigned warm-up device, 2 comfortable dry swings with a standard 83.8-cm, 652-g (33-in., 23-oz) softball bat followed by 3 maximal game swings (20-second rest between swings) while hitting a softball off a batting tee with the same standard softball bat. Results indicated that there were no statistically significant differences in BV after using any of the 8 warm-up devices (510.3-2,721.5 g or 18-96 oz) similar to in previous baseball research. This indicates that the results for both male and female intercollegiate players are similar and that intercollegiate softball players can use any of the 8 warm-up devices in the on-deck circle and have similar BVs. However, similar to in other previous baseball research, it is not recommended that female intercollegiate softball players warm up with the popular commercial donut ring in the on-deck circle because it produced the slowest BV.

  18. Microfluidic Devices in Advanced Caenorhabditis elegans Research

    Directory of Open Access Journals (Sweden)

    Muniesh Muthaiyan Shanmugam

    2016-08-01

    Full Text Available The study of model organisms is very important in view of their potential for application to human therapeutic uses. One such model organism is the nematode worm, Caenorhabditis elegans. As a nematode, C. elegans have ~65% similarity with human disease genes and, therefore, studies on C. elegans can be translated to human, as well as, C. elegans can be used in the study of different types of parasitic worms that infect other living organisms. In the past decade, many efforts have been undertaken to establish interdisciplinary research collaborations between biologists, physicists and engineers in order to develop microfluidic devices to study the biology of C. elegans. Microfluidic devices with the power to manipulate and detect bio-samples, regents or biomolecules in micro-scale environments can well fulfill the requirement to handle worms under proper laboratory conditions, thereby significantly increasing research productivity and knowledge. The recent development of different kinds of microfluidic devices with ultra-high throughput platforms has enabled researchers to carry out worm population studies. Microfluidic devices primarily comprises of chambers, channels and valves, wherein worms can be cultured, immobilized, imaged, etc. Microfluidic devices have been adapted to study various worm behaviors, including that deepen our understanding of neuromuscular connectivity and functions. This review will provide a clear account of the vital involvement of microfluidic devices in worm biology.

  19. Study of natural spin-parity strange meson radial excitations in K-p → K-π+n at 11 GeV/c

    International Nuclear Information System (INIS)

    Durkin, L.S.

    1980-12-01

    Results are presented from a high statistics study of the reaction K - p → K - π + n at 11 GeV/c. This data was selected offline from an approx. 1000 event/μb K - p experiment run on the Large Aperture Solenoid Spectrometer (LASS) at SLAC which triggered on essentially the total inelastic cross section. This K - π + n sample, after cuts, contained approx. 42,000 events in the Kπ invariant mass region from 0.65 GeV to 2.30 GeV, and absolute value t' 2 . A spherical harmonic angular moments analysis of this data is presented, as well as an energy independent partial wave analysis (PWA) of these angular moments. The nearly uniform acceptance characteristics of this data allowed a detailed analysis, which yielded information on natural spin-parity strange meson resonances in the Kπ invariant mass range from 0.65 GeV to 2.30 GeV. The well established K*(895), K*(1430), and K*(1780) are observed, and clear evidence is presented for a J/sup P/ = 4 + strange meson state at a mass of 2.08 GeV. The K - π + elastic scattering partial waves extracted in this PWA show unambiguous evidence for a relatively narrow S wave resonance near 1.42 GeV in the Kπ invariant mass. This state is a confirmation of the 0 + K(1500) seen in previous PWA's. A new higher S wave resonance is clearly seen unambiguously near 1.90 GeV. Unambiguous evidence is presented for a relatively wide P wave resonance in the 1.70 GeV region.A second new P wave resonance also is seen in two of four ambiguous partial wave solutions in the 2.10 GeV region. These resonance states are discussed within the framework of a simple harmonic oscillator quark model. In particular three of the underlying resonances are discussed as possible natural spin-parity strange meson radial excitations

  20. Intelligibility of clear speech: effect of instruction.

    Science.gov (United States)

    Lam, Jennifer; Tjaden, Kris

    2013-10-01

    The authors investigated how clear speech instructions influence sentence intelligibility. Twelve speakers produced sentences in habitual, clear, hearing impaired, and overenunciate conditions. Stimuli were amplitude normalized and mixed with multitalker babble for orthographic transcription by 40 listeners. The main analysis investigated percentage-correct intelligibility scores as a function of the 4 conditions and speaker sex. Additional analyses included listener response variability, individual speaker trends, and an alternate intelligibility measure: proportion of content words correct. Relative to the habitual condition, the overenunciate condition was associated with the greatest intelligibility benefit, followed by the hearing impaired and clear conditions. Ten speakers followed this trend. The results indicated different patterns of clear speech benefit for male and female speakers. Greater listener variability was observed for speakers with inherently low habitual intelligibility compared to speakers with inherently high habitual intelligibility. Stable proportions of content words were observed across conditions. Clear speech instructions affected the magnitude of the intelligibility benefit. The instruction to overenunciate may be most effective in clear speech training programs. The findings may help explain the range of clear speech intelligibility benefit previously reported. Listener variability analyses suggested the importance of obtaining multiple listener judgments of intelligibility, especially for speakers with inherently low habitual intelligibility.

  1. Thermonuclear device

    International Nuclear Information System (INIS)

    Takano, Hirohisa; Nakamoto, Kazunari; Hanai, Satoshi.

    1984-01-01

    Purpose: To provide coils of high mechanical strength for use at the center of a torus type thermonuclear device. Constitution: A plurality of copper plates having cooling holes and bolt holes and insulation paper sheets of the same shape are prepared. The copper plate is different from the insulation paper sheet only in that the position-phase angle of the opening portion is larger by 15 - 30 0 . The copper plates and the insulation paper sheets are alternately stacked by a required number of turns while displacing the angle, and then clamped by bolts to form a mechanically strong coil with no metallurgical joining. Further, since the insulation paper sheets are not present in the radial direction and only one insulation paper sheet is inserted for each turn in the direction of the coil height, the space occupied by the coil can be decreased. According to this invention, the magnetic flux density at the center of the device can be increased as compared with the conventional case to thereby apply a higher voltage on the side of plasmas. (Moriyama, K.)

  2. Irradiation damages of semiconductor devices and their improvement

    Energy Technology Data Exchange (ETDEWEB)

    Uwatoko, Yoshiya [Saitama Univ., Urawa (Japan); Ohyama, Hidenori; Hayama, Kiyoteru; Hakata, Tetsuya; Kudou, Tomohiro

    1998-01-01

    In this study, effect of radiation on semiconductor devices was evaluated at both sides of electrical and crystalline properties for two years from 1995 fiscal years. And, damage of Si(sub 1-x)Ge(sub x) device was considered at viewpoints of Ge content and sprung-out atomic number and non ionization energy loss of constituting atom formed by radiation on its radiation source dependency of damage. This paper was a report on proton beam damage of the Si(sub 1-x)Ge(sub x) device, neutron damage of InGaAs photodiode, and effect of Ga content and kinds of beam on their damages. (G.K.)

  3. Biomedical Impact in Implantable Devices-The Transcatheter Aortic Valve as an example

    Science.gov (United States)

    Anastasiou, Alexandros; Saatsakis, George

    2015-09-01

    Objective: To update of the scientific community about the biomedical engineering involvement in the implantable devices chain. Moreover the transcatheter Aortic Valve (TAV) replacement, in the field of cardiac surgery, will be analyzed as an example of contemporary implantable technology. Methods: A detailed literature review regarding biomedical engineers participating in the implantable medical product chain, starting from the design of the product till the final implantation technique. Results: The scientific role of biomedical engineers has clearly been established. Certain parts of the product chain are implemented almost exclusively by experienced biomedical engineers such as the transcatheter aortic valve device. The successful professional should have a multidisciplinary knowledge, including medicine, in order to pursue the challenges for such intuitive technology. This clearly indicates that biomedical engineers are among the most appropriate scientists to accomplish such tasks. Conclusions: The biomedical engineering involvement in medical implantable devices has been widely accepted by the scientific community, worldwide. Its important contribution, starting from the design and extended to the development, clinical trials, scientific support, education of other scientists (surgeons, cardiologists, technicians etc.), and even to sales, makes biomedical engineers a valuable player in the scientific arena. Notably, the sector of implantable devices is constantly raising, as emerging technologies continuously set up new targets.

  4. Systematic study of K+ and K- charge exchange at 8.36 and 12.8 GeV/c

    International Nuclear Information System (INIS)

    Gilchriese, M.G.D.

    1977-08-01

    The results of a wire chamber spectrometer experiment at the Stanford Linear Accelerator Center to study kaon charge exchange reactions are reported. The salient experimental features include good relative normalization between the K + and K - charge exchange reactions and a large increase, with respect to previous experiments, in the number of events obtained for K + n charge exchange at the higher energy. Approximately 1500 events at 12.8 GeV/c and 250 events at 8.36 GeV/c were obtained for each of the reactions K + n → K 0 p, K - p → anti K 0 n, K + p → K 0 Δ 2+ and K - n → anti K 0 Δ - . The results of the experiment show that the K + charge exchange cross sections are larger than the K - cross sections at both energies. In particular it is found that sigma/sub tot/ (K + n → K 0 p)/sigma/sub tot/ (K - p → anti K 0 n) is 1.37 +- 0.22 at 8.36 GeV/c and 1.38 +- 0.09 at 12.8 GeV/c. The ratio of these two reactions is also consistent with no momentum transfer dependence at either beam energy. Similarly it was determined that sigma/sub tot/ (K + p → K 0 Δ 2+ )/sigma/sub tot/ (K - n → anti K 0 Δ - ) is 1.05 +- 0.16 at 8.36 GeV/c and 1.56 +- 0.08 at 12.8 GeV/c. The ratio of these two reactions is also consistent with momentum transfer independence for both beam energies. These results are in clear conflict with the predictions of exchange degenerate Regge pole models

  5. Co-cultivation of mutant Penicillium oxalicum SAU(E)-3.510 and Pleurotus ostreatus for simultaneous biosynthesis of xylanase and laccase under solid-state fermentation.

    Science.gov (United States)

    Dwivedi, Pallavi; Vivekanand, V; Pareek, Nidhi; Sharma, Amit; Singh, Rajesh P

    2011-10-01

    Co-cultivation of mutant Penicillium oxalicum SAU(E)-3.510 and Pleurotus ostreatus MTCC 1804 was evaluated for the production of xylanase-laccase mixture under solid-state fermentation (SSF) condition. Growth compatibility between mutant P. oxalicum SAU(E)-3.510 and white rot fungi (P. ostreatus MTCC 1804, Trametes hirsuta MTCC 136 and Pycnoporus sp. MTCC 137) was analyzed by growing them on potato dextrose agar plate. Extracellular enzyme activities were determined spectrophotometrically. Under derived conditions, paired culturing of mutant P. oxalicum SAU(E)-3.510 and P. ostreatus MTCC 1804 resulted in 58% and 33% higher levels of xylanase and laccase production, respectively. A combination of sugarcane bagasse and black gram husk in a ratio of 3:1 was found to be the most ideal solid substrate and support for fungal colonization and enzyme production during co-cultivation. Maximum levels of xylanase (8205.31 ± 168.31 IU g(-1)) and laccase (375.53 ± 34.17 IU g(-1)) during SSF were obtained by using 4 g of solid support with 80% of moisture content. Furthermore, expressions of both xylanase and laccase were characterized during mixed culture by zymogram analysis. Improved levels of xylanase and laccase biosynthesis were achieved by co-culturing the mutant P. oxalicum SAU(E)-3.510 and P. ostreatus MTCC 1804. This may be because of efficient substrate utilization as compared to their respective monocultures in the presence of lignin degradation compounds because of synergistic action of xylanase and laccase. Understanding and developing the process of co-cultivation appears productive for the development of mixed enzyme preparation with tremendous potential for biobleaching. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Progress in the Study of RF Heating and Stabilization on HANBIT Mirror Device

    International Nuclear Information System (INIS)

    Kwon, M.; Bak, J.G.; Choh, K.; Choi, J.H.; Choi, J.W.; England, A.C.; Hong, J.S.; Jhang, H.G.; Kim, J.Y.; Kim, S.S.; Ko, W.H.; Lee, D.K.; Lee, J.H.; Lee, S.G.; Lee, H.G.; Lho, T.; Na, H.K.; Park, B.H.; Park, M.K.; Seo, D.C.; Seo, S.H.; Yeom, J.H.; Yoo, S.J.; You, K.I.; Yoon, J.S.; Yoon, S.W.

    2005-01-01

    The HANBIT device is a simple mirror-type device of which the length, radius, and magnetic field are about 5 m, 0.18 m, and 0.1-0.3 T, respectively, in the central cell. In HANBIT, two antenna systems are used for the plasma production, heating, and MHD stabilization; one is the slot antenna located near the center region with the maximum power of 500 kW and the typical frequency of 3.5 MHz, and the other DHT antenna located near the mirror throat with the maximum power of 100 kW and the frequency of 3.75 MHz. Recent experimental studies in HANBIT indicate that the slot antenna system can produce stable, high-density plasmas in apparently two different regimes; one is the fast wave regime with the ratio w/Wci∼2 and the other is the slow wave regime with w< Wci, where w and Wci are the RF and ion cyclotron resonance frequencies, respectively. The possible stabilization mechanism appears to be the ponderomotive force by the fast wave in the regime of w/Wci∼2, while the RF side-band coupling force by the slow wave in the regime of w< Wci. A clear excitation of the flute-type, interchange modes with the axial mode number n=0 is observed when the RF power is not enough for the stabilization, particularly, in the slow wave regime. Here, we report the results of these experimental and theoretical studies on the RF heating and stabilization processes by the slot antenna in HANBIT. In addition, we introduce briefly the results of the other on-going research works in HANBIT, which include the beach-wave ion heating experiment using DHT antenna, the pre-ionization experiment using the thermal electron cathode or ECH, and the analysis of plasma-wall interaction and neutral transport

  7. CO2 efflux from cleared mangrove peat.

    Directory of Open Access Journals (Sweden)

    Catherine E Lovelock

    Full Text Available CO(2 emissions from cleared mangrove areas may be substantial, increasing the costs of continued losses of these ecosystems, particularly in mangroves that have highly organic soils.We measured CO(2 efflux from mangrove soils that had been cleared for up to 20 years on the islands of Twin Cays, Belize. We also disturbed these cleared peat soils to assess what disturbance of soils after clearing may have on CO(2 efflux. CO(2 efflux from soils declines from time of clearing from ∼10,600 tonnes km(-2 year(-1 in the first year to 3000 tonnes km(2 year(-1 after 20 years since clearing. Disturbing peat leads to short term increases in CO(2 efflux (27 umol m(-2 s(-1, but this had returned to baseline levels within 2 days.Deforesting mangroves that grow on peat soils results in CO(2 emissions that are comparable to rates estimated for peat collapse in other tropical ecosystems. Preventing deforestation presents an opportunity for countries to benefit from carbon payments for preservation of threatened carbon stocks.

  8. Comparison of API 510 pressure vessels inspection planning with API 581 risk-based inspection planning approaches

    International Nuclear Information System (INIS)

    Shishesaz, Mohammad Reza; Nazarnezhad Bajestani, Mohammad; Hashemi, Seyed Javad; Shekari, Elahe

    2013-01-01

    To ensure mechanical integrity, all pressure vessels shall be inspected at the intervals provided in inspection codes or based on a risk-based inspection (RBI) assessment. The RBI assessment may allow previously established inspection intervals to be extended. This paper describes the methodology, analysis and results of two RBI studies conducted on 293 pressure vessel components in two crude oil distillation units. Based on API RBI methodology in API 581 (2008), risk target concept was used for determining inspection dates. It was shown that when thinning is the major active damage, the RBI recommended intervals are as long as twice the API 510 intervals. This paper summarizes that, as a fundamental step in the risk calculation, RBI has a more defined methodology for evaluating equipment for multiple damage mechanisms and a more defined approach to specify the use of other inspection technologies beyond the traditional visual, ultrasonic, and radiography tests. -- Highlights: • RBI calculated inspection intervals are as long as twice of API 510 inspection code. • Two case studies verified the advantage of RBI in inspection planning. • RBI is a more reliable methodology when evaluating multiple damage mechanisms. • Damage factor calculations can be used for determining RSFa value in FFS assessments

  9. Internalization, Clearing and Settlement, and Liquidity

    NARCIS (Netherlands)

    Degryse, H.A.; van Achter, M.; Wuyts, G.

    2012-01-01

    Abstract: We study the relation between liquidity in financial markets and post-trading fees (i.e. clearing and settlement fees). The clearing and settlement agent (CSD) faces different marginal costs for different types of transactions. Costs are lower for an internalized transaction, i.e. when

  10. A Framework for Quality K-12 Engineering Education: Research and Development

    Science.gov (United States)

    Moore, Tamara J.; Glancy, Aran W.; Tank, Kristina M.; Kersten, Jennifer A.; Smith, Karl A.; Stohlmann, Micah S.

    2014-01-01

    Recent U.S. national documents have laid the foundation for highlighting the connection between science, technology, engineering and mathematics at the K-12 level. However, there is not a clear definition or a well-established tradition of what constitutes a quality engineering education at the K-12 level. The purpose of the current work has been…

  11. The future of the pharmaceutical, biological and medical device industry

    Directory of Open Access Journals (Sweden)

    Burgess LJ

    2011-09-01

    Full Text Available Lesley J Burgess, Marli TerblancheTREAD Research/Cardiology Unit, Department of Internal Medicine, Tygerberg Hospital and University of Stellenbosch, Parow, South AfricaAbstract: Numerous factors contribute to the declining pharmaceutical industry on the one hand and the rapidly growing generic industry together with the growing importance of medical devices and biologicals on the other. It is clear that the pharmaceutical industry is going to undergo a change in the next decade in order to meet the current challenges facing it and ultimately sustain its profitability and growth. This paper aims to identify a number of fairly obvious trends that are likely to have a significant impact on the product development pipeline in the next decade. It is more than clear that the current production pipeline for pharmaceutical, biotechnology and medical device industries is no longer sustainable and that urgent interventions are required in order to maintain its current level of profitability.Keywords: pharmaceutical industry, personalized medicine, trends, generics, biotechnology

  12. Intracavitary deposits on Essure® hysteroscopic sterilization devices: A case report.

    Science.gov (United States)

    Maassen, L W; van Gastel, D M; Lentjes, E G W M; Bongers, M Y; Veersema, S

    2017-07-01

    To study the composition of intracavitary deposits on Essure® hysteroscopic sterilization devices. Case report. Reproductive Medicine and Gynecology department of a University Hospital. A 39 years old patient presenting with a request for surgical removal of Essure® sterilization devices. Diagnostic hysteroscopy showed a crystal like white deposit attached to one of the devices. Diagnostic hysteroscopy and surgical removal of Essure® devices was performed. The deposits were collected and infrared spectroscopy analysis was performed. Chemical composition of the deposits attached to the device. Infrared spectroscopy of the material showed patterns conclusive with calcite (calcium carbonate, CaCO 3 ). Until now, it is not clear if there is a relationship between reported complaints and formation of calcite deposits on Essure®. Infrared spectroscopy of deposits on Essure® devices showed a pattern conclusive with calcite. The relationship between reported complaints and the formation of calcite deposits on Essure® remains unclear.

  13. Lab-on-fiber electrophoretic trace mixture separating and detecting an optofluidic device based on a microstructured optical fiber.

    Science.gov (United States)

    Yang, Xinghua; Guo, Xiaohui; Li, Song; Kong, Depeng; Liu, Zhihai; Yang, Jun; Yuan, Libo

    2016-04-15

    We report an in-fiber integrated electrophoretic trace mixture separating and detecting an optofluidic optical fiber sensor based on a specially designed optical fiber. In this design, rapid in situ separation and simultaneous detection of mixed analytes can be realized under electro-osmotic flow in the microstructured optical fiber. To visually display the in-fiber separating and detecting process, two common fluorescent indicators are adopted as the optofluidic analytes in the optical fiber. Results show that a trace amount of the mixture (0.15 μL) can be completely separated within 3.5 min under a high voltage of 5 kV. Simultaneously, the distributed information of the separated analytes in the optical fiber can be clearly obtained by scanning along the optical fiber using a 355 nm laser. The emission from the analytes can be efficiently coupled into the inner core and guides to the remote end of the optical fiber. In addition, the thin cladding around the inner core in the optical fiber can prevent the fluorescent cross talk between the analytes in this design. Compared to previous optical fiber optofluidic devices, this device first realizes simultaneously separating treatment and the detection of the mixed samples in an optical fiber. Significantly, such an in-fiber integrated separating and detecting optofluidic device can find wide applications in various analysis fields involves mixed samples, such as biology, chemistry, and environment.

  14. Characterizations of MoTiO5 flash memory devices with post-annealing

    International Nuclear Information System (INIS)

    Kao, Chyuan Haur; Chen, Hsiang; Chen, Su Zhien; Chen, Yu Jie; Chu, Yu Cheng

    2014-01-01

    In this study, high-K MoTiO 5 dielectrics were applied as charge trapping layers in fabricated metal-oxide-high-K MoTiO 5 -oxide-Si-type memory devices. Among the applied MoTiO 5 trapping layer treatment conditions, annealing at 900 °C yielded devices that exhibited superior memory performance, such as a larger memory window and faster programming/erasing speed. Multiple material analyses, namely X-ray diffraction, X-ray photoelectron spectroscopy, and atomic force microscopy, confirmed that annealing at 900 °C can improve the material quality as a result of crystallization. The fabricated MoTiO 5 -based memory devices show potential for future commercial memory device applications. - Highlights: • MoTiO5-based flash memories have been fabricated. • MoTiO5 trapping layers could be formed by co-sputtering. • MoTiO5 layers with annealing exhibited a good memory performance. • Multiple material analyses confirm that annealing enhanced crystallization

  15. FY 2000 report on the trend survey of technical development of high speed/high function electronic devices such as quantum functional devices in association with the rationalization of energy utilization; 2000 nendo energy shiyo gorika ni kakawaru ryoshika kino soshi nado kosoku kokino denshi device no gijutsu kaihatsu doko chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Concerning the results of the R and D made by NEDO of superlattice devices (FY 1981-1990) and quantum functional devices (QFD) (FY 1991-2000) as high speed/high function electronic devices, this survey was aimed at investigating the trend of the newest technology to grasp the technical effects, the state of commercialization/product-making, and the future. The effects, technical subjects, etc. in the R and D of superlattice devices were succeeded to the R and D of QFD as the succeeding project. Here, therefore, the paper arranged the outlook of the commercialization/product-making in relation to the R and D of QFD and the future R and D subjects. In the R and D, features of QFD as target were made clear. The commercialization is limited to Motorola's QMMIC, Fujitsu's RHET, etc. As to the other R and D items, subjects of the technical development to be implemented toward the commercialization just became clear. The subject is the heightening of micro (nano meter) processing technology. The important subject, in particular, is compatibility of the heightening of micro processing and the improvement of throughput. (NEDO)

  16. Absorption-line detections of 10{sup 5}-10{sup 6} K gas in spiral-rich groups of galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Stocke, John T.; Keeney, Brian A.; Danforth, Charles W.; Syphers, David; Yamamoto, H.; Shull, J. Michael; Green, James C.; Froning, Cynthia [Center for Astrophysics and Space Astronomy, Department of Astrophysical and Planetary Sciences, University of Colorado, 389 UCB, Boulder, CO 80309 (United States); Savage, Blair D.; Wakker, Bart; Kim, Tae-Sun [Department of Astronomy, University of Wisconsin, Madison, WI 53706 (United States); Ryan-Weber, Emma V.; Kacprzak, Glenn G., E-mail: john.stocke@colorado.edu [Centre for Astrophysics and Supercomputing, Swinburne University of Technology, VIC 3122 (Australia)

    2014-08-20

    Using the Cosmic Origins Spectrograph (COS) on the Hubble Space Telescope, the COS Science Team has conducted a high signal-to-noise survey of 14 bright QSOs. In a previous paper, these far-UV spectra were used to discover 14 'warm' (T ≥ 10{sup 5} K) absorbers using a combination of broad Lyα and broad O VI absorptions. A reanalysis of a few of this new class of absorbers using slightly relaxed fitting criteria finds as many as 20 warm absorbers could be present in this sample. A shallow, wide spectroscopic galaxy redshift survey has been conducted around these sight lines to investigate the warm absorber environment, which is found to be spiral-rich groups or cluster outskirts with radial velocity dispersions σ = 250-750 km s{sup –1}. While 2σ evidence is presented favoring the hypothesis that these absorptions are associated with the galaxy groups and not with the individual, nearest galaxies, this evidence has considerable systematic uncertainties and is based on a small sample size so it is not entirely conclusive. If the associations are with galaxy groups, the observed frequency of warm absorbers (dN/dz = 3.5-5 per unit redshift) requires them to be very extended as an ensemble on the sky (∼1 Mpc in radius at high covering factor). Most likely these warm absorbers are interface gas clouds whose presence implies the existence of a hotter (T ∼ 10{sup 6.5} K), diffuse, and probably very massive (>10{sup 11} M {sub ☉}) intra-group medium which has yet to be detected directly.

  17. Evolutionary relationships within a subgroup of HERV-K-related human endogenous retroviruses

    NARCIS (Netherlands)

    Zsíros, J.; Jebbink, M. F.; Lukashov, V. V.; Voûte, P. A.; Berkhout, B.

    1998-01-01

    The prototype endogenous retrovirus HERV-K10 was identified in the human genome by its homology to the exogenous mouse mammary tumour virus. By analysis of a short 244 bp segment of the reverse transcriptase (RT) gene of other HERV-K10-like sequences, it has become clear that these elements

  18. Are new supraglottic airway devices, tracheal tubes and airway viewing devices cost-effective?

    Science.gov (United States)

    Slinn, Simon J; Froom, Stephen R; Stacey, Mark R W; Gildersleve, Christopher D

    2015-01-01

    Over the past two decades, a plethora of new airway devices has become available to the pediatric anesthetist. While all have the laudable intention of improving patient care and some have proven clinical benefits, these devices are often costly and at times claims of an advantage over current equipment and techniques are marginal. Supraglottic airway devices are used in the majority of pediatric anesthetics delivered in the U.K., and airway-viewing devices provide an alternative for routine intubation as well as an option in the management of the difficult airway. Yet hidden beneath the convenience of the former and the technology of the latter, the impact on basic airway skills with a facemask and the lack of opportunities to fine-tune the core skill of intubation represent an unrecognised and unquantifiable cost. A judgement on this value must be factored into the absolute purchase cost and any potential benefits to the quality of patient care, thus blurring any judgement on cost-effectiveness that we might have. An overall value on cost-effectiveness though not in strict monetary terms can then be ascribed. In this review, we evaluate the role of these devices in the care of the pediatric patient and attempt to balance the advantages they offer against the cost they incur, both financial and environmental, and in any quality improvement they might offer in clinical care. © 2014 John Wiley & Sons Ltd.

  19. Working Characteristics of a Mechanical Insufflation-Exsufflation Device

    Directory of Open Access Journals (Sweden)

    Yan Shi

    2014-01-01

    Full Text Available Secretions of ventilated patients must be cleared efficiently and timely; to improve the secretion clearance efficiency of an insufflation-exsufflation device (IL-IE device and lay a foundation for the optimization of the IL-IE device, a mathematical model of the ventilation system with the IL-IE device is set up. Through the experimental and simulation research on the ventilation system, it can be concluded that, firstly, the mathematical model is proved to be authentic and reliable. Secondly, with the deposition of secretion or an increase in the respiratory compliance, the peak exsufflation airflow may be reduced. Thirdly, with a decrease in the suction pressure, the peak exsufflation airflow of the ventilated lung may rise proportionally, but the minimum pressure in the ventilated lung may descend proportionally. To improve the efficiency of the secretion clearance but not to injure the ventilated patient, the suction pressure can be elevated properly. Last, increasing the inspiratory positive airway pressure (IPAP is a method to improve the secretion clearance efficiency. This research lays a foundation for improving the secretion clearance efficiency of the IL-IE device.

  20. Device for measuring fission product density

    International Nuclear Information System (INIS)

    Kaneda, Mitsunori.

    1980-01-01

    Purpose: To determine the fission product density of xenon or the like and enable measurement of real time of fission product density in a reactor by calculating the disintegration and annihilation of the fission product on the basis of neutron detected output. Constitution: The neutron flux in a reactor is detected by a detector, and applied to first and second density calculators. Second fission product density signal of xenon or the like outputted from first device is again inputted to the device to form an annihilation signal due to disintegration to determine the present density of the second fission product of xenon or the like corresponding to the decrease of the neutron due to the poison of xeron or the like. Similarly, second device determines the first fission product density of iodine or the like. (Sekiya, K.)

  1. Temperature control for liquid-helium cryostats below 4.2 K

    International Nuclear Information System (INIS)

    Escorne, M.; Mauger, A.

    1983-01-01

    We report the operational characteristics of a membrane type of manostat and of a throttle valve system which we have constructed to regulate the pressure P above the liquid-helium bath. The choice of the manostat rather than the other device depends on the nature of the experiments to be performed: in the membrane type of manostat, the temperature is determined with an accuracy limited by the fluctuations ΔT around the mean value T. With throttle valves, the accuracy is limited by the drift of T in time. The performance of both devices prove to be sufficiently good as they stand, since the departure from T in the course of the experiments is lower than 10 -2 K in the whole range 1.4< T<4.2 K, being well inside this limit below 2 K. The need for expensive and complex electronic regulations to improve the temperature control is thus exceptional

  2. Carnot type magnetic refrigeration below 4.2 K - computer simulation

    International Nuclear Information System (INIS)

    Hashimoto, T.; Numazawa, T.; Maro, T.

    1984-01-01

    Cooling devices based on a utilization of the Carnot type magnetic refrigeration cycle are usually selected for the temperature range from 20 K to 1.8 K. However, the refrigeration power in the case of such devices is frequently limited by the heat transfer coefficient between the heat source and the magnetic working substance. Thus, in a magnetic refrigerator studied by Delpuech et al. (1981), the refrigeration power is mainly restricted by the heat transfer coefficient in the isothermal magnetization process at 4.2 K. The present investigation is concerned with the development of a method for achieving high refrigeration power on the basis of a study utilizing computer simulation. One of two methods considered for enhancing refrigeration power is related to the change in the magnetic field, while the other method involves an enlargement of the effective area of gadolinium-gallium-garnet (GGG) with the aid of deep grooves in the surface. 6 references

  3. Preliminary results on a 4 kJ, 140 k A plasma focus

    International Nuclear Information System (INIS)

    Silva, Patricio; Favre, Mario; Chuaqui, Hernan; Wyndham, Edmund

    1996-01-01

    Preliminary results on the operation of a 4 kJ, 140 kA Plasma Focus device are presented. The machine operates Hydrogen and Hydrogen-Argon mixtures at pressures between 400 m Torr to 10 Torr. Main diagnostics include electric and current measurements, time and space resolved X-ray observations, with limited spectral resolution, and B-dot sensors to monitor the evolution of de current sheet during the run up phase of the discharge. The results indicate that good focus is obtained in the above pressure range. This is inferred from I-dot traces and Pin diode and pin-hole camera X-ray observations. The B-dot loops suggest that a symmetric current sheet is produced. These results show that the machine exhibits a reliable performance, which allows further studies on dense transient plasmas to be developed. (author)

  4. Thermal modeling and design of electronic systems and devices

    International Nuclear Information System (INIS)

    Wirtz, R.A.; Lehmann, G.L.

    1990-01-01

    The thermal control electronic devices, particularly those in complex systems with high heat flux density, continues to be of interest to engineers involved in system cooling design and analysis. This volume contains papers presented at the 1990 ASME Winter Annual Meeting in two K-16 sponsored sessions: Empirical Modeling of Heat Transfer in Complex Electronic Systems and Design and Modeling of Heat Transfer Devices in High-Density Electronics. The first group deals with understanding the heat transfer processes in these complex systems. The second group focuses on the use of analysis techniques and empirically determined data in predicting device and system operating performance

  5. Effect of mechanical optical clearing on near-infrared spectroscopy.

    Science.gov (United States)

    Idelson, Christopher R; Vogt, William C; King-Casas, Brooks; LaConte, Stephen M; Rylander, Christopher G

    2015-08-01

    Near-infrared Spectroscopy (NIRS) is a broadly utilized technology with many emerging applications including clinical diagnostics, sports medicine, and functional neuroimaging, to name a few. For functional brain imaging NIR light is delivered at multiple wavelengths through the scalp and skull to the brain to enable spatial oximetry measurements. Dynamic changes in brain oxygenation are highly correlated with neural stimulation, activation, and function. Unfortunately, NIRS is currently limited by its low spatial resolution, shallow penetration depth, and, perhaps most importantly, signal corruption due to light interactions with superficial non-target tissues such as scalp and skull. In response to these issues, we have combined the non-invasive and rapidly reversible method of mechanical tissue optical clearing (MOC) with a commercially available NIRS system. MOC utilizes a compressive loading force on tissue, causing the lateral displacement of blood and water, while simultaneously thinning the tissue. A MOC-NIRS Breath Hold Test displayed a ∼3.5-fold decrease in the time-averaged standard deviation between channels, consequentially promoting greater channel agreement. A Skin Pinch Test was implemented to negate brain and muscle activity from affecting the recorded signal. These results displayed a 2.5-3.0 fold increase in raw signal amplitude. Existing NIRS instrumentation has been further integrated within a custom helmet device to provide a uniform force distribution across the NIRS sensor array. These results showed a gradual decrease in time-averaged standard deviation among channels with an increase in applied pressure. Through these experiments, and the development of the MOC-NIRS helmet device, MOC appears to provide enhancement of NIRS technology beyond its current limitations. © 2015 Wiley Periodicals, Inc.

  6. 78 FR 54507 - Clearing Agency; the Options Clearing Corporation; Notice of Filing of Proposed Rule Change To...

    Science.gov (United States)

    2013-09-04

    ... risk arising from the potential need to liquidate a particular clearing member's margin collateral, OCC... by improving OCC's risk management process related to deposits as margin collateral of concentrated... and Policy so that OCC has discretion to disapprove as margin collateral for a particular clearing...

  7. Development of superconducting equipment for fusion device

    International Nuclear Information System (INIS)

    Konno, Masayuki; Ueda, Toshio; Hiue, Hisaaki; Ohgushi, Kouzou

    1993-01-01

    At Fuji Electric Co., Ltd., the development of superconductivity was started from 1960, and superconducting equipment for fusion device has been developed for ten years. The superconducting equipment, which is developed for fusion by Fuji Electric Co., Ltd., are able to be grouped in three categories which are current lead, superconducting coil and superconducting bus-line. The current lead is an electrical feeder between a superconducting coil and an electrical power supply. The rated current of developed current lead is 30kA at continuous use and 100kA at short time use respectively. The advanced disk type coil is developed for the toroidal field coil and some coils are developed for critical current measurement. Superconductor is applied to the superconducting bus-line between the superconducting coils and the current leads, and the bus-line is being developed for the Large Helical Device. This report describes an abstract of these equipment. (author)

  8. A microfluidic dialysis device for complex biological mixture SERS analysis

    KAUST Repository

    Perozziello, Gerardo

    2015-08-01

    In this paper, we present a microfluidic device fabricated with a simple and inexpensive process allowing rapid filtering of peptides from a complex mixture. The polymer microfluidic device can be used for sample preparation in biological applications. The device is fabricated by micromilling and solvent assisted bonding, in which a microdialysis membrane (cut-off of 12-14 kDa) is sandwiched in between an upper and a bottom microfluidic chamber. An external frame connects the microfluidic device to external tubes, microvalves and syringe pumps. Bonding strength and interface sealing are pneumatically tested. Microfluidic protocols are also described by using the presented device to filter a sample composed of specific peptides (MW 1553.73 Da, at a concentration of 1.0 ng/μl) derived from the BRCA1 protein, a tumor-suppressor molecule which plays a pivotal role in the development of breast cancer, and albumin (MW 66.5 kDa, at a concentration of 35 μg/μl), the most represented protein in human plasma. The filtered samples coming out from the microfluidic device were subsequently deposited on a SERS (surface enhanced Raman scattering) substrate for further analysis by Raman spectroscopy. By using this approach, we were able to sort the small peptides from the bigger and highly concentrated protein albumin and to detect them by using a label-free technique at a resolution down to 1.0 ng/μl.

  9. Y2K: Focus on systems

    International Nuclear Information System (INIS)

    Dillner, M.

    1999-01-01

    During the past three years the Pacific Northwest National Laboratory has been actively working with the US DOE to understand the Y2K impacts that exist and perform appropriate remediation of critical systems. The Y2K problem has the potential for affecting software, hardware, embedded chips, control devices as well as telephone and power equipment. Successful Y2K remediation requires that a risk assessment be performed based on a view of the 'complete' system (e.g. input, outputs, infrastructure, operating systems, communication mechanisms, and development tools as compilers). All DOE facilities have followed the Y2K life cycle of system inventory, assessment (system and risk), renovation, testing, transition planning, implementation, validation and business continuity planning. Within this process, each organization has used the particular systems life-cycle methodology. The Pacific Northwest National Laboratory would like to share lessons learned about the entire Year 2000 program particularly in the areas of performing Year 2000 assessments, the identification of appropriate system remediation, and project mechanisms

  10. Reactor protecting device

    International Nuclear Information System (INIS)

    Ono, Hiroshi; Kasuga, Hajime; Kasuga, Hiroshi.

    1984-01-01

    Purpose: To reduce the recycling flowrate thereby decrease the neutron flux level before the reactor shutdown upon generation of abnormality such as increase in the neutron flux, by setting the safety level lower than the value for generating the reaction scram signal. Constitution: A netron flux safety level setter and an instruction signal generator are disposed between a neutron flux detector and a recycling flowrate control device. A neutron flux safety level lower than the level for generating a reactor scram signal and higher that the level for the ordinary operation is set and, if the detection level for the neutron flux in the reactor core arrives at the safety level, a neutron flux decreasing instruction signal is outputted from the instruction signal generator to the recycling flowrate control device to thereby decrease the recycling flowrate and decrease the neutron flux without reaching the reactor shutdown, whereby the thermal safety of the fuel rod can be maintained and the reactor operation performance can be improved. (Moriyama, K.)

  11. Nomad devices for interactions in immersive virtual environments

    Science.gov (United States)

    George, Paul; Kemeny, Andras; Merienne, Frédéric; Chardonnet, Jean-Rémy; Thouvenin, Indira Mouttapa; Posselt, Javier; Icart, Emmanuel

    2013-03-01

    Renault is currently setting up a new CAVE™, a 5 rear-projected wall virtual reality room with a combined 3D resolution of 100 Mpixels, distributed over sixteen 4k projectors and two 2k projector as well as an additional 3D HD collaborative powerwall. Renault's CAVE™ aims at answering needs of the various vehicle conception steps [1]. Starting from vehicle Design, through the subsequent Engineering steps, Ergonomic evaluation and perceived quality control, Renault has built up a list of use-cases and carried out an early software evaluation in the four sided CAVE™ of Institute Image, called MOVE. One goal of the project is to study interactions in a CAVE™, especially with nomad devices such as IPhone or IPad to manipulate virtual objects and to develop visualization possibilities. Inspired by nomad devices current uses (multi-touch gestures, IPhone UI look'n'feel and AR applications), we have implemented an early feature set taking advantage of these popular input devices. In this paper, we present its performance through measurement data collected in our test platform, a 4-sided homemade low-cost virtual reality room, powered by ultra-short-range and standard HD home projectors.

  12. Primary clear cell sarcoma of rib

    International Nuclear Information System (INIS)

    Hersekli, Murat Ali; Ozkoc, Gurkan; Akpinar, Sercan; Ozalay, Metin; Tandogan, Reha N.; Bircan, Sema; Tuncer, Ilhan

    2005-01-01

    Clear cell sarcoma (malignant melanoma of soft tissues) is a very rare soft tissue neoplasm. It generally arises in tendons and aponeuroses. Although metastasis of malignant melanoma to bone is not uncommon, primary clear cell sarcoma of bone is an extremely rare neoplasm. To our knowledge five cases have been reported in the English literature. We present a case of primary clear cell sarcoma of bone in a 28-year-old woman arising in the left ninth rib. We treated the patient with total excision of the mass and postoperative radiotherapy. The patient is alive and well without local recurrence or distant metastasis at 33 months after surgery. (orig.)

  13. Selection of K+ mesons in a secondary beam of Saturne (1961)

    International Nuclear Information System (INIS)

    Van Rossum, L.

    1961-01-01

    The electronic device is described which permitted the determination of the number of K + mesons produced in a secondary beam of the 'Saturne' proton synchrotron. The selective criteria and the tests which allowed the identification of the K + mesons, are analysed in detail. For the ratio π + / K + = 400, and with a momentum of 600 MeV/c, less than 5 p. 100 of the detected particles corresponded to spurious events. (authors) [fr

  14. Incorporating antenna beamswitching technique into drivers for IEEE802.11 WLAN devices

    CSIR Research Space (South Africa)

    Mofolo, M

    2015-11-23

    Full Text Available the beamswitching technique for switched parasitic array (SPA) and electronically steerable parasitic array radiator (ESPAR) antennas in the drivers for IEEE802.11 WLAN devices. The modifications of the open source drivers (ath5k and ath9k) to enable real...

  15. The problem of clear air turbulence

    Indian Academy of Sciences (India)

    Due to rapid improvements in on-board instrumentation and atmospheric observation systems, in most cases, aircraft are able to steer clear of regions of adverse weather. However, they still encounter unexpected bumpy flight conditions in regions away from storms and clouds. This is the phenomenon of clear air ...

  16. Characterizing infantile hemangiomas with a near-infrared spectroscopic handheld wireless device

    Science.gov (United States)

    Fong, Christopher J.; Hoi, Jennifer W.; Kim, Hyun K.; Behr, Gerald; Geller, Lauren; Antonov, Nina; Flexman, Molly; Garzon, Maria; Hielscher, Andreas H.

    2015-03-01

    Infantile hemangiomas (IH) are common vascular growths that occur in 5-10% of neonates and have the potential to cause disfiguring and even life-threatening complications. Currently, no objective tool exist to monitor either progression or treatment of IH. To address this unmet clinical need, we have developed a handheld wireless device (HWD) that uses diffuse optical spectroscopy for the assessment of IH. The system employs 4 wavelengths (l=780nm, 805nm, 850nm, and 905nm) and 6 source-detector pairs with distances between 0.6 and 20 mm. Placed on the skin surface, backreflection data is obtained and a multispectral evolution algorithm is used to determine total hemoglobin concentration and tissue oxygen saturation. First results of an ongoing pilot study involving 13 patients (average enrollment age = 25 months) suggest that an increase in hypoxic stress over time can lead to the proliferation of IH. Involuting IH lesions showed an increase in tissue oxygen saturation as well as a decrease in total hemoglobin.

  17. Clear-air lidar dark band

    Science.gov (United States)

    Girolamo, Paolo Di; Scoccione, Andrea; Cacciani, Marco; Summa, Donato; Schween, Jan H.

    2018-04-01

    This paper illustrates measurements carried out by the Raman lidar BASIL in the frame of HOPE, revealing the presence of a clear-air dark band phenomenon (i.e. the appearance of a minimum in lidar backscatter echoes) in the upper portion of the convective boundary layer. The phenomenon is clearly distinguishable in the lidar backscatter echoes at 1064 nm. This phenomenon is attributed to the presence of lignite aerosol particles advected from the surrounding open pit mines in the vicinity of the measuring site.

  18. Effect of Enzymatic Digestion of Protein Derivatives Obtained from Mucuna pruriens L. on Production of Proinflammatory Mediators by BALB/c Mouse Macrophages.

    Science.gov (United States)

    Martínez Leo, Edwin E; Arana Argáez, Victor E; Acevedo Fernández, Juan J; Puc, Rosa Moo; Segura Campos, Maira R

    2018-04-25

    Inflammation is considered to be a major risk factor for the pathogenesis of chronic non-communicable diseases. Macrophages are important immune cells, which regulate inflammation and host defense by secretion of proinflammatory mediators. Obtaining biopeptides by enzymatic hydrolysis adds value to proteins of vegetative origin, such as Mucuna pruriens L. The present study evaluated the effect of enzymatic digestion of protein derivatives obtained from M. pruriens L. on the production of proinflammatory mediators by BALB/c mouse macrophages. Five different molecular weight peptide fractions were obtained (F > 10, 5-10, 3-5, 1-3, and < 1 kDa, respectively). At 300 μg/mL, F5-10 kDa inhibited 50.26 and 61.00% NO and H 2 O 2 production, respectively. Moreover, F5-10 kDa reduced the IL-6 and TNFα levels to 60.25 and 69.54%, respectively. After enzymatic digestive simulation, F5-10 kDa decreased the inflammatory mediators.

  19. K-dron, its mathematical modeling and applications

    Directory of Open Access Journals (Sweden)

    Janusz Kapusta

    2016-01-01

    Full Text Available In this paper we present the definition of K-dron, new geometrical form discovered by Janusz Kapusta in 1985 in New York, its history and connection between geometry and symmetry of a cube. It is worth to emphasize that the authors have derived new formulae for the surface of K-dron using the Laplaceatransform in order to obtain the solution of the boundary-value problem for the partial differential equation describing the vibration of the string. The formula proved by us in this paper is clearer and understandable in view of this structure. The solution obtained in this paper describes in general manner the surface of K-dron and more general surfaces named by us n-K-drons. The formula for the surface of K-dron was derived by the method of Laplacea transform having clear geometrical and physical interpretation because it is presented in linear combination of the equation of planes with the coefficients of directions described by suitable combinations of Heavisides functions. Also wide range and different applications of K-dron are presented.[b]Słowa kluczowe[/b]: K-dron, Laplace’a transform, partial differential of string equation of vibration, initial-boundary value problems

  20. Security of Semi-Device-Independent Random Number Expansion Protocols.

    Science.gov (United States)

    Li, Dan-Dan; Wen, Qiao-Yan; Wang, Yu-Kun; Zhou, Yu-Qian; Gao, Fei

    2015-10-27

    Semi-device-independent random number expansion (SDI-RNE) protocols require some truly random numbers to generate fresh ones, with making no assumptions on the internal working of quantum devices except for the dimension of the Hilbert space. The generated randomness is certified by non-classical correlation in the prepare-and-measure test. Until now, the analytical relations between the amount of the generated randomness and the degree of non-classical correlation, which are crucial for evaluating the security of SDI-RNE protocols, are not clear under both the ideal condition and the practical one. In the paper, first, we give the analytical relation between the above two factors under the ideal condition. As well, we derive the analytical relation under the practical conditions, where devices' behavior is not independent and identical in each round and there exists deviation in estimating the non-classical behavior of devices. Furthermore, we choose a different randomness extractor (i.e., two-universal random function) and give the security proof.

  1. Thermonuclear device

    International Nuclear Information System (INIS)

    Inoue, Toyokazu; Murata, Toru.

    1983-01-01

    Purpose: To shield superconducting coils for use in the generation of magnetic field against neutron irradiation thereby preventing tritium contamination. Constitution: The thermonuclear device comprises, in its inside, a vacuum container for containing plasmas, superconducting coils disposed to the outside of the vacuum container and neutron absorbers disposed between the super-conducting coils and the vacuum container. since neutrons issued from the plasma are absorbed by neutron absorbers and not irradiated to the superconducting coils, generation of tritium due to the reaction between 3 He in the liquid helium as the coolants for the super-conducting coils and the neutrons is prevented. (Aizawa, K.)

  2. Power Factor Improvement Using Automatic Power Factor Compensation (APFC Device for Medical Industries in Malaysia

    Directory of Open Access Journals (Sweden)

    Zaidi Maryam Nabihah

    2018-01-01

    Full Text Available This paper present the project designed to correcting power factor for medical industries in Malaysia automatically. Which with hope to make the cost and energy usage efficient, because the energy source are depleting due to increase in population. Power factor is the ratio of real power and apparent power. This definition is mathematically represented as kW/kVA where kW is active power and kVA is apparent power (active + reactive. Reactive power is the non-working power generated by the magnetic and inductive load to generate magnetic flux. The increase in reactive power increase the apparent power so the power factor will decrease. Low pF will cause the industry to meet high demand thus making it less efficient. The main aim of this project is to increasing the current power factor of medical industries from 0.85 to 0.90. Power factor compensation contribute to reduction in current-dependent losses and increase energy efficiency while expanding the reliability of planning for future energy network. As technology develops, the gradual cost and efficiency penalty should reduce. Therefore, automatic power factor compensation device should become cost-effective and smaller device over time. That is the reason this project is using programmable device as it is a miniature architecture device.

  3. Spike-Timing Dependent Plasticity in Unipolar Silicon Oxide RRAM Devices.

    Science.gov (United States)

    Zarudnyi, Konstantin; Mehonic, Adnan; Montesi, Luca; Buckwell, Mark; Hudziak, Stephen; Kenyon, Anthony J

    2018-01-01

    Resistance switching, or Resistive RAM (RRAM) devices show considerable potential for application in hardware spiking neural networks (neuro-inspired computing) by mimicking some of the behavior of biological synapses, and hence enabling non-von Neumann computer architectures. Spike-timing dependent plasticity (STDP) is one such behavior, and one example of several classes of plasticity that are being examined with the aim of finding suitable algorithms for application in many computing tasks such as coincidence detection, classification and image recognition. In previous work we have demonstrated that the neuromorphic capabilities of silicon-rich silicon oxide (SiO x ) resistance switching devices extend beyond plasticity to include thresholding, spiking, and integration. We previously demonstrated such behaviors in devices operated in the unipolar mode, opening up the question of whether we could add plasticity to the list of features exhibited by our devices. Here we demonstrate clear STDP in unipolar devices. Significantly, we show that the response of our devices is broadly similar to that of biological synapses. This work further reinforces the potential of simple two-terminal RRAM devices to mimic neuronal functionality in hardware spiking neural networks.

  4. Use of gold as monostandard for the determination of elemental concentrations in environmental SRMs and Ganga river sediments by the k0 method

    International Nuclear Information System (INIS)

    Ramakrishna, V.V.S.; Acharya, R.N.; Reddy, A.V.R.; Garg, A.N.

    2001-01-01

    Instrumental neutron activation analysis (INAA) using the k 0 method by employing gold as monostandard has been used for the determination of 18 elements (As, Ba, Br, Cl, Cr, Co, Cs, Dy, Fe, Hf, Ga, In, La, Mn, Na, Rb, Sc and Th) in standard reference materials (SRMs) of environmental origin and four sediment samples collected from the Ganga river in northern parts of India. Data obtained for SRMs agree within ±5-10% with the certified values for most elements. Merits and demerits of the k 0 method are discussed. An attempt has been made to identify the sources of heavy metal pollutants in the sediment samples and study the mobility pattern for toxic heavy metals originating from the tanneries along with the river flow

  5. 677C to T mutation in the 5,10-methylenetetrahydrofolate reductase (MTHFR) gene and plasma homocyst(e)ine levels in patients with TIA or minor stroke.

    Science.gov (United States)

    Lalouschek, W; Aull, S; Korninger, L; Mannhalter, C; Pabinger-Fasching, I; Schmid, R W; Schnider, P; Zeiler, K

    1998-03-05

    It was the aim of this study to determine the associations of clinical and laboratory data with plasma homocyst(e)ine levels in patients with transient ischemic attack (TIA) or minor stroke (MS), with special reference to their 677C to T mutation status in the 5,10-methylenetetrahydrofolate reductase (5,10-MTHFR) gene. Seventy-six patients with TIA or MS were investigated at least 3 months after their (last) clinical event. By means of univariate analysis, significant correlations of homocyst(e)ine levels with male gender (Pine levels. After adjustment for age, creatinine levels and homocyst(e)ine levels remained significantly correlated to each other (Pine levels was no longer significant (P=0.10). Mutation-positive patients exhibited moderately and statistically non-significantly higher homocyst(e)ine levels than mutation-negative patients, particularly those who were homozygous positive. Homocyst(e)ine levels were closely correlated with creatinine levels (Pine levels in patients with TIA or MS are dependent on the 5,10-MTHFR mutation status. Significant correlations between these variables were found only in mutation-positive but not in mutation-negative patients.

  6. Hydrogen Production from Water by Photosynthesis System I for Use as Fuel in Energy Conversion Devices (a.k.a. Understanding Photosystem I as a Biomolecular Reactor for Energy Conversion)

    Science.gov (United States)

    2014-04-01

    Hydrogen Production from Water by Photosynthesis System I for Use as Fuel in Energy Conversion Devices (a.k.a. Understanding Photosystem I as...Laboratory Adelphi, MD 20783-1197 ARL-TR-6904 April 2014 Hydrogen Production from Water by Photosynthesis System I for Use as Fuel in Energy...Final 3. DATES COVERED (From - To) 10/1/2010–10/1/2013 4. TITLE AND SUBTITLE Hydrogen Production from Water by Photosynthesis System I for Use as Fuel

  7. Evaluation of the Olympus AU-510 analyser.

    Science.gov (United States)

    Farré, C; Velasco, J; Ramón, F

    1991-01-01

    The selective multitest Olympus AU-510 analyser was evaluated according to the recommendations of the Comision de Instrumentacion de la Sociedad Española de Quimica Clinica and the European Committee for Clinical Laboratory Standards. The evaluation was carried out in two stages: an examination of the analytical units and then an evaluation in routine work conditions. The operational characteristics of the system were also studied.THE FIRST STAGE INCLUDED A PHOTOMETRIC STUDY: dependent on the absorbance, the inaccuracy varies between +0.5% to -0.6% at 405 nm and from -5.6% to 10.6% at 340 nm; the imprecision ranges between -0.22% and 0.56% at 405 nm and between 0.09% and 2.74% at 340 nm. Linearity was acceptable, apart from a very low absorbance for NADH at 340 nm; and the imprecision of the serum sample pipetter was satisfactory.TWELVE SERUM ANALYTES WERE STUDIED UNDER ROUTINE CONDITIONS: glucose, urea urate, cholesterol, triglycerides, total bilirubin, creatinine, phosphate, iron, aspartate aminotransferase, alanine aminotransferase and gamma-glutamyl transferase.The within-run imprecision (CV%) ranged from 0.67% for phosphate to 2.89% for iron and the between-run imprecision from 0.97% for total bilirubin to 7.06% for iron. There was no carryover in a study of the serum sample pipetter. Carry-over studies with the reagent and sample pipetters shows some cross contamination in the iron assay.

  8. 76 FR 45730 - Customer Clearing Documentation and Timing of Acceptance for Clearing

    Science.gov (United States)

    2011-08-01

    ... proposing regulations to facilitate customer access to clearing and to bolster risk management through... and execution of customer transactions on a DCM or SEF on terms that have a reasonable relationship to... a reasonable relationship to the best terms available by prohibiting restrictions in customer...

  9. Multicenter study of the COPD-6 screening device: feasible for early detection of chronic obstructive pulmonary disease in primary care?

    Science.gov (United States)

    Kjeldgaard, Peter; Lykkegaard, Jesper; Spillemose, Heidi; Ulrik, Charlotte Suppli

    2017-01-01

    Early detection of COPD may reduce the future burden of the disease. We aimed to investigate whether prescreening with a COPD-6 screening device (measuring FEV 1 and FEV 6 ) facilitates early detection of COPD in primary care. In primary care, individuals at high risk of COPD (ie, age ≥35 years, relevant exposure, and at least one respiratory symptom) and no previous diagnosis of obstructive lung disease were examined with a COPD-6 screening device. In prioritized order, the criteria for proceeding to confirmatory spirometry were FEV 1 /FEV 6 COPD regardless of test result (medical doctor's [MD] decision). Based on spirometry, including bronchodilator (BD) reversibility test, individuals were classified as COPD (post-BD FEV 1 /FVC COPD-6 screening to confirmative spirometry based on the following criteria: 510 (54%) FEV 1 /FEV 6 COPD (51%), asthma (3%), and no obstructive lung disease (45%). COPD was diagnosed in 487 (16%) of the enrolled subjects in whom confirmative spirometry was performed in 69% based on FEV 1 /FEV 6 COPD-6 device showed acceptable specificity for the selection of subjects for diagnostic spirometry and is likely to be a useful alternative to current practice in primary care.

  10. Automatic control device for the reduction of reactor power

    International Nuclear Information System (INIS)

    Sumida, Susumu; Mizuno, Hiroshi.

    1982-01-01

    Purpose: To early detect troubles in condensate pipeways and feedwater pipeways of BWR-type reactor. Constitution: Detectors are provided to a condensate pipe, a condensator, a low pressure condensate pump, a condensate desalting device and a high pressure condensate pump for constituting condensate pipeways, as well as to a feedwater heater, a feedwater pipe and a feedwater pump for constituting feedwater pipeways. Each of the detectors is connected by way of a lead wire to an abnormal detection and processing device. The abnormal detection and processing device, which are connected to a recycling control device, monitor the input from the detector and sends a control signal to the recycling control system upon calculation of a trouble signal from the detector. (Sekiya, K.)

  11. 1.8kW laser diode pumped YAG laser; Shutsuryoku 1.8kW no handotai laser reiki YAG laser

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Toshiba Corporation, as a participant in Ministry of International Trade and Industry`s `photon measurement and processing technology project` since August, 1997, is engaged in the development of an energy-efficient LD (laser diode) pumped semiconductor YAG (yttrium-aluminum-garnet) laser device to be used for welding and cutting. It is a 5-year project and the goal is a mean output of 10kW and efficiency of 20%. In this article, a simulation program is developed which carries out calculation about element technology items such as the tracking of the beam from the pumping LD and the excitation distribution, temperature distribution, thermal stress distribution, etc., in the YAG rod. An oscillator is constructed, based on the results of the simulation, and it exhibits a world-high class continuous laser performance of a 1.8kW output and 13% efficiency. The record of 13% efficiency is five times higher than that achieved by the conventional lamp-driven YAG laser device. (translated by NEDO)

  12. Anterior Crossbite and Crowding Correction with a Series of Clear Aligners Involving Lower Incisor Extraction: "The Clear Way" Case Report.

    Science.gov (United States)

    Bawaskar, Naval Suresh

    2015-01-01

    The Clear Aligner can be used to correct tooth movement without involving extraction, surgery, and other adjunct orthopaedic appliances. Some forms ofattachments are required with clear aligners to achieve all major types of orthodontic tooth movements. The Clear Aligner is a procedure that can be performed by a clinician with computer simulation/calculation. Since the Clear Aligner can be fabricated in steps, it is readily available to change the treatment sequence throughout the course of the treatment in cases of complex malocclusions. The patient can receive any necessary dental procedures with ease during the course of the treatment. The treatment can also be easily resumed even if the patient has not worn the aligners for a period of time. The purpose of this article is to report dental anterior crossbite correction with a series of Clear Aligners without the use of any forms of attachments. The Clear Aligner could be used as an alternative in appropriate cases for those who are reluctant with conventional appliances.

  13. Experimental investigations of an air curtain device subjected to external perturbations

    International Nuclear Information System (INIS)

    Havet, M.; Rouaud, O.; Solliec, C.

    2003-01-01

    Although plane air jets are often used as dynamic barriers to separate two environments, only a few works have explored their sensitivity to perturbations. We investigated the influence of sharp changes of pressure on the flow field of a device designed to avoid air-borne contamination. Laser tomography and tracer gas experiments clearly indicate that the air curtain is strongly sensitive to perturbations such as draughts. The results highlight that the control of air curtains used in open protection devices should be further investigated

  14. How Do K-12 Students' Manage Applications on Their Mobile Devices?

    Science.gov (United States)

    Aladjem, Ruthi; Hardof, Sharon

    2016-01-01

    Personal information management (PIM) is a research field that examines the activities by which users save, organize and retrieve personal information items. PIM is a one of the essential new literacies for learners in the 21st century. This paper reports results from a pilot study that explored PIM practices and strategies of K-12 students, on…

  15. Development of a thermally switched superconducting rectifier for 100 kA

    NARCIS (Netherlands)

    Mulder, G.B.J.; Mulder, G.B.J.; ten Kate, Herman H.J.; Krooshoop, Hendrikus J.G.; van de Klundert, L.J.M.; van de Klundert, L.J.M.

    1991-01-01

    A full-wave superconducting rectifier for 100 kA has been developed. Typical design values of this device are: a secondary current of 100 kA, a primary amplitude of 20 A, an operating frequency of 0.5 Hz, and an average power on the order of 100 W. The rectification is achieved by means of thermally

  16. SRV-automatic handling device

    International Nuclear Information System (INIS)

    Yamada, Koji

    1987-01-01

    Automatic handling device for the steam relief valves (SRV's) is developed in order to achieve a decrease in exposure of workers, increase in availability factor, improvement in reliability, improvement in safety of operation, and labor saving. A survey is made during a periodical inspection to examine the actual SVR handling operation. An SRV automatic handling device consists of four components: conveyor, armed conveyor, lifting machine, and control/monitoring system. The conveyor is so designed that the existing I-rail installed in the containment vessel can be used without any modification. This is employed for conveying an SRV along the rail. The armed conveyor, designed for a box rail, is used for an SRV installed away from the rail. By using the lifting machine, an SRV installed away from the I-rail is brought to a spot just below the rail so that the SRV can be transferred by the conveyor. The control/monitoring system consists of a control computer, operation panel, TV monitor and annunciator. The SRV handling device is operated by remote control from a control room. A trial equipment is constructed and performance/function testing is carried out using actual SRV's. As a result, is it shown that the SRV handling device requires only two operators to serve satisfactorily. The required time for removal and replacement of one SRV is about 10 minutes. (Nogami, K.)

  17. Thermodynamic Analysis of TEG-TEC Device Including Influence of Thomson Effect

    Science.gov (United States)

    Feng, Yuanli; Chen, Lingen; Meng, Fankai; Sun, Fengrui

    2018-01-01

    A thermodynamic model of a thermoelectric cooler driven by thermoelectric generator (TEG-TEC) device is established considering Thomson effect. The performance is analyzed and optimized using numerical calculation based on non-equilibrium thermodynamic theory. The influence characteristics of Thomson effect on the optimal performance and variable selection are investigated by comparing the condition with and without Thomson effect. The results show that Thomson effect degrades the performance of TEG-TEC device, it decreases the cooling capacity by 27 %, decreases the coefficient of performance (COP) by 19 %, decreases the maximum cooling temperature difference by 11 % when the ratio of thermoelectric elements number is 0.6, the cold junction temperature of thermoelectric cooler (TEC) is 285 K and the hot junction temperature of thermoelectric generator (TEG) is 450 K. Thomson effect degrades the optimal performance of TEG-TEC device, it decreases the maximum cooling capacity by 28 % and decreases the maximum COP by 28 % under the same junction temperatures. Thomson effect narrows the optimal variable range and optimal working range. In the design of the devices, limited-number thermoelectric elements should be more allocated appropriately to TEG when consider Thomson effect. The results may provide some guidelines for the design of TEG-TEC devices.

  18. MODELING OF THREE-PHASE THREE LEG TRANSFORMER DEVICES FOR ENGINEERING CALCULATIONS OF ASYMMETRICAL MODES FOR DIFFERENT SCHEMES OF WINDING CONNECTIONS

    Directory of Open Access Journals (Sweden)

    Bosneaga V.A

    2013-08-01

    Full Text Available The model is proposed for the calculation and research of steady state asymmetric modes and transients in three-phase three legs transformer devices with arbitrary diagram of windings connection, taking into account the electromagnetic coupling of the windings, located on different legs. Using as an example distribution transformer of 10/0.4 kV calculations and analysis were performed of the most characteristic steady asymmetrical modes, that occur during short circuit, phase failure, unbalanced load for the most common windings connections and, in particular, associated with the occurrence of zero sequence magnetic flow. For the considered regimes and schemes vector diagrams were constructed for currents and voltages as well as for the relative values of magnetic flow, which give a clear idea about their particular features.

  19. Initiation and propagation of cleared channels in neutron-irradiated pure copper and a precipitation hardened CuCrZr alloy

    DEFF Research Database (Denmark)

    Singh, B.N; Edwards, D.J.; Bilde-Sørensen, Jørgen

    2004-01-01

    The phenomenon of plastic flow localization in the form of "cleared" channels has been frequently observed in neutron irradiated metals and alloys for more than 40 years. So far, however, no experimental evidence as to how and where these channels areinitiated during post-irradiation deformation...... has emerged. Recently we have studied the problem of initiation and propagation of cleared channels during post-irradiation tensile tests of pure copper and a copper alloy irradiated with fission neutrons.Tensile specimens of pure copper and a precipitation hardened copper alloy (CuCrZr) were neutron...... irradiated at 323 and 373K to displacement doses in the range of 0.01 to 0.3 dpa (displacement per atom) and tensile tested at the irradiation temperature.The stress-strain curves clearly indicated the occurrence of a yield drop. The post-deformation microstructural examinations revealed that the channels...

  20. Ca II H and K emission from late-type stars

    International Nuclear Information System (INIS)

    Middlekoop, F.

    1982-01-01

    This thesis is based on a study of the Ca II H and K emission features of late main-sequence stars. In Chapter II it is shown that rotation periods can be determined from a modulation in the Ca II H and K signal for many stars in a broad range of spectral types. In Chapter III it is shown that a clear correlation exists between Ca II H and K emission and rotational velocity in active main-sequence stars. There is an indication for a (probably colour-dependent) critical velocity at which the Ca II H and K emission suddenly drops. Chapter IV discusses the dependence of Ca II H and K emission on the rotation rate for evolved stars. (Auth./C.F.)

  1. Component-Level Electronic-Assembly Repair (CLEAR) Operational Concept

    Science.gov (United States)

    Oeftering, Richard C.; Bradish, Martin A.; Juergens, Jeffrey R.; Lewis, Michael J.; Vrnak, Daniel R.

    2011-01-01

    This Component-Level Electronic-Assembly Repair (CLEAR) Operational Concept document was developed as a first step in developing the Component-Level Electronic-Assembly Repair (CLEAR) System Architecture (NASA/TM-2011-216956). The CLEAR operational concept defines how the system will be used by the Constellation Program and what needs it meets. The document creates scenarios for major elements of the CLEAR architecture. These scenarios are generic enough to apply to near-Earth, Moon, and Mars missions. The CLEAR operational concept involves basic assumptions about the overall program architecture and interactions with the CLEAR system architecture. The assumptions include spacecraft and operational constraints for near-Earth orbit, Moon, and Mars missions. This document addresses an incremental development strategy where capabilities evolve over time, but it is structured to prevent obsolescence. The approach minimizes flight hardware by exploiting Internet-like telecommunications that enables CLEAR capabilities to remain on Earth and to be uplinked as needed. To minimize crew time and operational cost, CLEAR exploits offline development and validation to support online teleoperations. Operational concept scenarios are developed for diagnostics, repair, and functional test operations. Many of the supporting functions defined in these operational scenarios are further defined as technologies in NASA/TM-2011-216956.

  2. Clear sky solar insolation data for Islamabad

    International Nuclear Information System (INIS)

    Akhter, P.; Baig, A.; Mufti, A.

    1990-09-01

    Monthly average values of both integrated and instantaneous clear sky solar radiation components for Islamabad territory have been presented and discussed. The components include total, direct normal, direct horizontal, global and diffuse radiations, sun hours, number of clear days and temperature for solar energy applications. Beam irradiance values are used to get clear sky (maximum) sun hours by ab-initio. The need for replacing the conventional sunshine recorder is discussed. (author). 8 refs, 1 fig, 2 tabs

  3. Gain stabilization circuit of measuring devices with photomultipliers

    International Nuclear Information System (INIS)

    Seda, J.; Sabol, J.

    1974-01-01

    A circuit is designed for the stabilization of the gain of measuring devices with photomultipliers, suitable especially for the stabilization of scintillation detection systems, in which the correction signal is applied to the photomultiplier grid placed between the photocathode and the first dynode. (J.K.)

  4. Current state of low energy EB devices and its application technology

    International Nuclear Information System (INIS)

    Kinoshita, Shinobu

    2000-01-01

    This paper introduced the current state of low energy type EB (electron beam) devices with an acceleration voltage of 300 kV or below and specific application examples. As for EB devices, it introduced the ultra-compact new EB device (microbeam LV), experimental devices, and the pilot/production devices which have been recently developed by the manufacturer to which the author belongs. As the applications of low energy EB devices, it specifically introduced curing, graft polymerization, crosslinking, and sterilization/disinfection with soft electrons: (1) examples of EB curing; antistatic agents in antibacterial/antifungal property imparting processing, hard coat, printing and topcoat, high gloss/pattern transfer processing, and metal vapor deposition film, (2) example of graft polymerization; barrier imparting films, and (3) examples of crosslinking; shrinking films/tubes and foamed sheets. (A.O.)

  5. The TI-Nspire CAS: A Happy-Medium Mobile Device for Grades 8-16 Mathematics Classrooms

    Science.gov (United States)

    Zelkowski, Jeremy

    2011-01-01

    This article justifies classifying the TI-Nspire CAS Touchpad as a mobile device for grades 8-16 mathematics classrooms equipped with a Navigator system. The 2010 Horizon Report: K-12 indicates virtually every secondary school aged child has some sort of mobile device. Yet, many school policies ban the use of mobile devices, preventing students…

  6. Thermoluminescence in alkali halides irradiated at 80K; Termoluminiscencia en haluros alcalinos irradiados a 80K

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez de Castro, M

    1978-07-01

    The thermoluminescence, the thermally stimulated currents and the thermal stability of the F centres induced in pure NaCl and KC1 crystals by X irradiation at 80K have been studied in detail, In the range between 80 and 300K. The thermoluminescent processes induced by illumination at 80K with F light in samples previously irradiated at room temperature has also been studied. It has been clearly observed the existence of thermoluminescent processes due to electrons and holes thermally released from traps, in which the F centres are not involved. The existence of hole-F centre recombination has not been observed. There are several thermoluminescent processes in both materials which are scribed to the recombination of F centres with mobile interstitial halogen atoms thermally released from traps, which are likely monovalent impurities in this temperature interval. The light emitting stage in these processes is originated by the formation of self trapped excitons. (Author) 66 refs.

  7. Dynamics of 120 and 20 kV plasma focus devices with respect to density and current distribution, neutron and X-ray emission

    International Nuclear Information System (INIS)

    Decker, G.; Nahrath, B.; Oppenlaender, T.; Pross, G.; Rueckle, B.; Schmidt, H.; Shakhatre, M.; Trunk, M.

    1976-01-01

    Our experiments have aimed at two goals: 1) better understanding of the dynamics and neutron production of the focus phase and 2) improved scaling of the neutron yield by operating a high voltage focus. 1) For the first goal, experiments with a 30 kJ/ 16 kV plasma focus of the Mather type (NESSI) were performed. The simultaneously applied diagnostics include interferometry, X-ray photography with channel plates, magnetic probes and neutron emission. In the established chronology we can distinguish 5 phases in the development of the plasma focus: a compression phase is followed by a short (8 ns) very dense phase, where the density peaks at a minimum radius (t = 0 in our chronology). The plasma cylinder expands to a relatively long lasting (30 to 70 ns) quiescent phase before instabilities occur. This short unstable phase is followed by a decay phase during which the neutron emission peaks. Important correlations between the plasma parameters and the neutron emission are discussed. 2) Under the assumption that the neutron yield scales with a high power of the current, we concluded that a high voltage focus could result in higher neutron yield as compared with a lower voltage device of the same energy. The proper adjustments of the discharge parameters necessary due to the very short current risetime have been investigated. (orig.) [de

  8. Traversing incore probe device

    International Nuclear Information System (INIS)

    Yoshioka, Michiko.

    1985-01-01

    Purpose: To measure the neutron flux distribution in the reactor core always at a high accuracy. Constitution: A nuclear fission ionizing chamber type detector is disposed at the end of a cable for sending a detection signal of a traversing incore probe device and, further, a gamma-ray ionizing chamber type detector is connected in adjacent therewith and a selection circuit for selecting both of the detection signals and inputting them to a display device is disposed. Then, compensation for the neutron monitors is conducted by the gamma-ray ionizing chamber type detector during normal operation in which control rods are not driven and the positioning is carried out by the nuclear fission ionizing chamber type detector. Furthermore, both of the compensation for the neutron detector and the positioning are carried out by the nuclear fission ionizing chamber type detector upon starting where the control rods are driven. (Sekiya, K.)

  9. Multicenter study of the COPD-6 screening device: feasible for early detection of chronic obstructive pulmonary disease in primary care?

    DEFF Research Database (Denmark)

    Kjeldgaard, Peter; Lykkegaard, Jesper; Spillemose, Heidi

    2017-01-01

    of COPD (ie, age ≥35 years, relevant exposure, and at least one respiratory symptom) and no previous diagnosis of obstructive lung disease were examined with a COPD-6 screening device. In prioritized order, the criteria for proceeding to confirmatory spirometry were FEV1/FEV6 ..., or clinical suspicion of COPD regardless of test result (medical doctor's [MD] decision). Based on spirometry, including bronchodilator (BD) reversibility test, individuals were classified as COPD (post-BD FEV1/FVC ...,990 subjects (54% men, mean age 59 years, and mean 28 pack-years) were enrolled, of whom 949 (32%) proceeded from COPD-6 screening to confirmative spirometry based on the following criteria: 510 (54%) FEV1/FEV6 spirometry, the 949...

  10. Investigation of thioglycerol stabilized ZnS quantum dots in electroluminescent device performance

    Science.gov (United States)

    Ethiraj, Anita Sagadevan; Rhen, Dani; Lee, D. H.; Kang, Dae Joon; Kulkarni, S. K.

    2016-05-01

    The present work is focused on the investigation of thioglycerol (TG) stabilized Zinc Sulfide Quantum dots (ZnS QDs) in the hybrid electroluminescence (EL) device. Optical absorption spectroscopy clearly indicates the formation of narrow size distributed ZnS in the quantum confinement regime. X-ray Diffraction (XRD), Photoluminescence (PL), Energy Dispersive X-ray Spectroscopy (EDS) data supports the same. The hybrid EL device with structure of ITO (indium tin oxide)//PEDOT:PSS ((poly(3,4-ethylenedioxythiophene)-poly(styrene sulfonate)//HTL (α NPD- N,N'-diphenyl-N,N'-bis(1-naphthyl)-(1,1'-phenyl)-4,4'-diamine// PVK:ZnS QDs//ETL(PBD- 2-tert-butylphenyl- 5-biphenyl-1,3,4-oxadiazole)//LiF:Al (Device 1) was fabricated. Reference device without the ZnS QDs were also prepared (Device 2). The results show that the ZnS QDs based device exhibited bright electroluminescence emission of 24 cd/m2 at a driving voltage of 16 Volts under the forward bias conditions as compared to the reference device without the ZnS QDs, which showed 6 cd/m2 at ˜22 Volts.

  11. Preionization Techniques in a kJ-Scale Dense Plasma Focus

    Science.gov (United States)

    Povilus, Alexander; Shaw, Brian; Chapman, Steve; Podpaly, Yuri; Cooper, Christopher; Falabella, Steve; Prasad, Rahul; Schmidt, Andrea

    2016-10-01

    A dense plasma focus (DPF) is a type of z-pinch device that uses a high current, coaxial plasma gun with an implosion phase to generate dense plasmas. These devices can accelerate a beam of ions to MeV-scale energies through strong electric fields generated by instabilities during the implosion of the plasma sheath. The formation of these instabilities, however, relies strongly on the history of the plasma sheath in the device, including the evolution of the gas breakdown in the device. In an effort to reduce variability in the performance of the device, we attempt to control the initial gas breakdown in the device by seeding the system with free charges before the main power pulse arrives. We report on the effectiveness of two techniques developed for a kJ-scale DPF at LLNL, a miniature primer spark gap and pulsed, 255nm LED illumination. Prepared by LLNL under Contract DE-AC52-07NA27344.

  12. Device for measuring well twistings

    Energy Technology Data Exchange (ETDEWEB)

    Kostin, Yu S; Golubin, S V; Keller, V F; Merzheyevskiy, A B; Zdorov, V P

    1982-01-01

    The device for measuring the well twistings with the use of fluids (poured into a vessel and which leave an imprint on the walls), containing a housing and adapter, is distinguished by the fact that in order to improve the accuracy of measurement by obtaining a clear imprint, it is equipped with cylinder that is spring-loaded in relation to the adapter, forming a vessel for fluid with the adapter. The adapter is made of two parts, one of which is made of neutral metal in relation to the fluid, and the other, from active in relation to the same fluid.

  13. Mobile Apps for Reflection in Learning: A Design Research in K-12 Education

    Science.gov (United States)

    Leinonen, Teemu; Keune, Anna; Veermans, Marjaana; Toikkanen, Tarmo

    2016-01-01

    This study takes a design-based research approach to explore how applications designed for mobile devices could support reflection in learning in K-12 education. Use of mobile devices is increasing in schools. Most of the educational apps support single-person use of interactive learning materials, simulations and learning games. Apps designed to…

  14. PdTe: a 4.5 K type-II BCS superconductor

    International Nuclear Information System (INIS)

    Tiwari, Brajesh; Goyal, Reena; Jha, Rajveer; Awana, V P S; Dixit, Ambesh

    2015-01-01

    We report on the structure and physical properties of the polycrystalline PdTe superconductor, which is synthesized by the solid state reaction route via the quartz vacuum encapsulation technique at 750 °C. The as synthesized compound is crystallized in hexagonal crystal structure with P63/mmc space group. Both transport and magnetic measurements showed that PdTe is a bulk superconductor below 4.5 K. Isothermal magnetization (MH) and magneto-transport (R(T)H) measurements provided the values of the lower (H c1 ) and upper (H c2 ) critical fields as 250 Oe and 1200 Oe respectively at 2 K, establishing that the compound is clearly a type-II superconductor. The coherence length (ξ 0 ) and Ginzburg–Landau parameter (κ) are estimated from the experimentally determined upper and lower critical fields, and are 449 Å and 1.48 respectively. Thermodynamic heat capacity measurements under different magnetic fields, i.e. C p (T)H, showed a clear transition at 4.5 K (T c ), which shifts gradually to lower temperatures with application of field. The values of Debye temperature (Θ D ) and electronic specific heat coefficient (γ) obtained from C p (T) data are found to be 203 K and 6.01 mJ mol −1 K −2 . The observed specific heat jump (ΔC/γT c ) is 1.33, thus suggesting a possible weak coupling case for the PdTe superconductor. (paper)

  15. Crystal growth of hexaferrite architecture for magnetoelectrically tunable microwave semiconductor integrated devices

    Science.gov (United States)

    Hu, Bolin

    crystal growth technique is considered theoretically and experimentally to be universal and suitable for the growth of a wide range of diverse crystals. In the present experiment, the conical spin structure of Co2Y ferrite crystals were a found to give rise to an intrinsic magnetoelectric effect. Our experiment reveals a remarkable increase in the conical phase transition temperature by ~150 K for Co 2Y ferrite, compared to 5--10 K of Zn2Y ferrites recently reported. The high quality Co2Y ferrite crystals, having low microwave loss and magnetoelectricity, were successfully grown on wide bandgap semiconductor GaN. The demonstration of the nanostructure materials-based "system on a wafer" architecture is a critical milestone to next generation microwave integrated systems. It is also practical that future microwave integrated systems and their magnetic performances could be tuned by an electric field because of the magnetoelectricity of hexaferrites.

  16. High Power Microwave Emission of Large and Small Orbit Gyrotron Devices in Rectangular Interaction Structures

    Science.gov (United States)

    Hochman, J. M.; Gilgenbach, R. M.; Jaynes, R. L.; Rintamaki, J. I.; Luginsland, J. W.; Lau, Y. Y.; Spencer, T. A.

    1996-11-01

    Experiments utilize large and small orbit e-beam gyrotron devices in a rectangular-cross-section (RCS) gyrotron. This device is being explored to examine polarization control. Other research issues include pulse shortening, and mode competition. MELBA generates electron beams with parameters of: -800kV, 1-10kA diode current, and 0.5-1.0 μ sec pulselengths. The small orbit gyrotron device is converted to a large orbit experiment by running MELBA's annular electron beam through a magnetic cusp. Initial experiments showed an increase in beam alpha (V_perp/V_par) of a factor of ~ 4 between small and large orbit devices. Experimental results from the RCS gyrotron will be compared for large-orbit and small-orbit electron beams. Beam transport data and frequency measurements will be presented. Computer modeling utilizing the MAGIC and E-gun codes will be shown.

  17. Testing Framework for Mobile Device Forensics Tools

    Directory of Open Access Journals (Sweden)

    Maxwell Anobah

    2014-09-01

    Full Text Available The proliferation of mobile communication and computing devices, in particular smart mobile phones, is almost paralleled with the increasing number of mobile device forensics tools in the market. Each mobile forensics tool vendor, on one hand claims to have a tool that is best in terms of performance, while on the other hand each tool vendor seems to be using different standards for testing their tools and thereby defining what support means differently. To overcome this problem, a testing framework based on a series of tests ranging from basic forensics tasks such as file system reconstruction up to more complex ones countering antiforensic techniques is proposed. The framework, which is an extension of an existing effort done in 2010, prescribes a method to clearly circumscribe the term support into precise levels. It also gives an idea of the standard to be developed and accepted by the forensic community that will make it easier for forensics investigators to quickly select the most appropriate tool for a particular mobile device.

  18. 76 FR 45724 - Clearing Member Risk Management

    Science.gov (United States)

    2011-08-01

    ... proposed rules address risk management for cleared trades by futures commission merchants, swap dealers... Commission has proposed extensive regulations addressing open access and risk management at the derivatives..., 2011) (Risk Management Requirements for Derivatives Clearing Organizations). These proposed regulations...

  19. Lanthanum Gadolinium Oxide: A New Electronic Device Material for CMOS Logic and Memory Devices

    Directory of Open Access Journals (Sweden)

    Shojan P. Pavunny

    2014-03-01

    Full Text Available A comprehensive study on the ternary dielectric, LaGdO3, synthesized and qualified in our laboratory as a novel high-k dielectric material for logic and memory device applications in terms of its excellent features that include a high linear dielectric constant (k of ~22 and a large energy bandgap of ~5.6 eV, resulting in sufficient electron and hole band offsets of ~2.57 eV and ~1.91 eV, respectively, on silicon, good thermal stability with Si and lower gate leakage current densities within the International Technology Roadmap for Semiconductors (ITRS specified limits at the sub-nanometer electrical functional thickness level, which are desirable for advanced complementary metal-oxide-semiconductor (CMOS, bipolar (Bi and BiCMOS chips applications, is presented in this review article.

  20. Comparison of seven optical clearing methods for mouse brain

    Science.gov (United States)

    Wan, Peng; Zhu, Jingtan; Yu, Tingting; Zhu, Dan

    2018-02-01

    Recently, a variety of tissue optical clearing techniques have been developed to reduce light scattering for imaging deeper and three-dimensional reconstruction of tissue structures. Combined with optical imaging techniques and diverse labeling methods, these clearing methods have significantly promoted the development of neuroscience. However, most of the protocols were proposed aiming for specific tissue type. Though there are some comparison results, the clearing methods covered are limited and the evaluation indices are lack of uniformity, which made it difficult to select a best-fit protocol for clearing in practical applications. Hence, it is necessary to systematically assess and compare these clearing methods. In this work, we evaluated the performance of seven typical clearing methods, including 3DISCO, uDISCO, SeeDB, ScaleS, ClearT2, CUBIC and PACT, on mouse brain samples. First, we compared the clearing capability on both brain slices and whole-brains by observing brain transparency. Further, we evaluated the fluorescence preservation and the increase of imaging depth. The results showed that 3DISCO, uDISCO and PACT posed excellent clearing capability on mouse brains, ScaleS and SeeDB rendered moderate transparency, while ClearT2 was the worst. Among those methods, ScaleS was the best on fluorescence preservation, and PACT achieved the highest increase of imaging depth. This study is expected to provide important reference for users in choosing most suitable brain optical clearing method.