WorldWideScience

Sample records for clear lens extraction

  1. Assessment of phacoaspiration techniques in clear lens extraction for correction of high myopia

    Directory of Open Access Journals (Sweden)

    Mostafa A El-Helw

    2010-03-01

    Full Text Available Mostafa A El-Helw, Ahmed M EmarahDepartment of Ophthalmology, Cairo University, EgyptPurpose: To evaluate various phacoaspiration techniques in clear lens extraction for the incidence of intraoperative difficulties and complications.Patients and methods: This was a prospective study in which bilateral clear lens extraction was performed on 40 eyes of 20 patients, to correct high myopia. The patients were divided into 2 groups: group A underwent supracapsular phacoaspiration; group B were the contralateral eyes of the same patient. These patients were operated on with endocapsular phacoaspiration with the divide and conquer (D and C technique. Preoperative ocular examination data were recorded and tested for significance. Intraoperative difficulties and complications such as nucleus cracking, capsule rupture and vitreous loss, and repeated chamber collapse were recorded. Postoperative examination data were recorded.Results: Mean age was 35.65 ± 5.85 years. Mean follow-up time was 17.1 ± 8.56 months. In group A mean myopia was -17.3 ± 5.07 diopters; in group B myopia was -17.9 ± 4.20 diopters. Mean preoperative uncorrected visual acuity (UCVA was 0.04 ± 0.0167, while the mean postoperative UCVA was 0.435 ± 0.1442. There was a significant difference in pre and postoperative BCVA within both groups, but not between the two groups. In both groups endothelial cell count (ECC showed a significant difference between pre- and postoperative data; however, there was no statistically significant difference between both groups in postoperative ECC. The effective phacoaspiration time for group A was 4.6 ± 1.6 seconds, and for group B 9.90 ± 2.27 seconds (P < 0.005. No cases of capsule rupture occurred in group A, but 3 cases occurred in group B (15 % (not significant, P = 0.231. Nucleus cracking did not occur in group A, but in group B 13 cases occurred (65%. Chamber collapse occurred in 4 cases (20% in group A and 5 cases (25% in group B (not

  2. A split-electrode for clearing scattered electrons in the RHIC e-lens

    Energy Technology Data Exchange (ETDEWEB)

    Gu X.; Pikin, A.; Thieberger, P.; Fischer, W.; Hock, J.; Hamdi, K.; Gassner,D.; Luo, Y.; Montag, C.; Okamura, M.

    2012-05-20

    We are designing two electron lenses that will be installed at RHIC IR10 to compensate for the head-on beam-beam effect. To clear accumulated scattered electrons from 100 GeV proton-electron head-on collisions in the e-lens, a clearing split electrode may be constructed. The feasibility of this proposed electrode was demonstrated via the CST Particle Studio and Opera program simulations. By splitting one of the drift tubes in the e-lens and applying {approx} 380 V across the two parts, the scattered electrons can be cleared out within several hundred micro-seconds. At the same time we can restrict the unwanted shift of the primary electron-beam that already passed the 2-m interaction region in e-lens, to less than 15um.

  3. [The effect of crystalline lens extraction on intraocular pressure in patients with primary open-angle glaucoma].

    Science.gov (United States)

    Macarie, S; Macarie, Daniela

    2013-01-01

    This issue presents the results of a study on patients with cataract and primary open angle glaucoma who suffered lens extraction for cataract. We analise the effects of the lens extraction on the level of intraocular pressure at this patients.

  4. Extracapsular cataract extraction : the fate of retained lens material and intraocular lenses

    NARCIS (Netherlands)

    J.P. Kappelhof (Johan)

    1987-01-01

    textabstractThe aim of this study was to examine the fate of the lens material that remains in the eye after an extracapsular cataract extraction both with and without insertion of an intraocular lens. Apart from this, the development of precipitates on the intraocular lenses was morphologically inv

  5. Dipole magnet and quadrupole lens for the slow extraction of a beam from the Dubna synchrophasotron

    International Nuclear Information System (INIS)

    The deflection system for the second slow extraction (SE-2) of a beam of protons and nuclei from the Dubna synchrophasotron consists of a dipole septum-magnet (VM-2) and a quadrupole septum-lens (VL-2). The magnet, the lens, the current conductors for supplying their windings and the driver used for the SE-2 system are described. A general scheme of cooling the windings of the magnet, lens and conductors is presented. The magnetic characteristics of the VM-2 magnet and the VL-2 lens are given. The system used to control the parameters of the SE-2 is described. 4 refs.; 16 figs

  6. Anterior Crossbite and Crowding Correction with a Series of Clear Aligners Involving Lower Incisor Extraction: "The Clear Way" Case Report.

    Science.gov (United States)

    Bawaskar, Naval Suresh

    2015-01-01

    The Clear Aligner can be used to correct tooth movement without involving extraction, surgery, and other adjunct orthopaedic appliances. Some forms ofattachments are required with clear aligners to achieve all major types of orthodontic tooth movements. The Clear Aligner is a procedure that can be performed by a clinician with computer simulation/calculation. Since the Clear Aligner can be fabricated in steps, it is readily available to change the treatment sequence throughout the course of the treatment in cases of complex malocclusions. The patient can receive any necessary dental procedures with ease during the course of the treatment. The treatment can also be easily resumed even if the patient has not worn the aligners for a period of time. The purpose of this article is to report dental anterior crossbite correction with a series of Clear Aligners without the use of any forms of attachments. The Clear Aligner could be used as an alternative in appropriate cases for those who are reluctant with conventional appliances. PMID:27029089

  7. Eyeglasses lens contour extraction from facial images using an efficient shape description.

    Science.gov (United States)

    Borza, Diana; Darabant, Adrian Sergiu; Danescu, Radu

    2013-10-10

    This paper presents a system that automatically extracts the position of the eyeglasses and the accurate shape and size of the frame lenses in facial images. The novelty brought by this paper consists in three key contributions. The first one is an original model for representing the shape of the eyeglasses lens, using Fourier descriptors. The second one is a method for generating the search space starting from a finite, relatively small number of representative lens shapes based on Fourier morphing. Finally, we propose an accurate lens contour extraction algorithm using a multi-stage Monte Carlo sampling technique. Multiple experiments demonstrate the effectiveness of our approach.

  8. Eyeglasses Lens Contour Extraction from Facial Images Using an Efficient Shape Description

    Directory of Open Access Journals (Sweden)

    Diana Borza

    2013-10-01

    Full Text Available This paper presents a system that automatically extracts the position of the eyeglasses and the accurate shape and size of the frame lenses in facial images. The novelty brought by this paper consists in three key contributions. The first one is an original model for representing the shape of the eyeglasses lens, using Fourier descriptors. The second one is a method for generating the search space starting from a finite, relatively small number of representative lens shapes based on Fourier morphing. Finally, we propose an accurate lens contour extraction algorithm using a multi-stage Monte Carlo sampling technique. Multiple experiments demonstrate the effectiveness of our approach.

  9. Quadrupole lens and extraction magnets of a compact race-track microtron

    OpenAIRE

    Vladimirov, Ivan; Pakhomov, Nikolai; Shvedunov, Vasiliy; Koubychine Merkulov, Youri Alexandrovich; Rigla Perez, Juan Pablo; Zakharov, Vitaliy

    2014-01-01

    The compact race-track microtron (RTM) with a maximum energy of 12 MeV that is under construction at the Technical University of Catalonia consists of a quadrupole lens for horizontal focusing of the beam and four dipole magnets for the extraction of the beam from the accelerator. The source of the magnetic field in the magnets is a rare-earth permanent magnet (REPM). The main characteristics of the quadrupole lens and the extraction magnets and the procedure for the tuning of their ...

  10. In vitro prevention of cataract by Oyster Mushroom Pleurotus florida extract on isolated goat eye lens

    Directory of Open Access Journals (Sweden)

    Aditya Ganeshpurkar

    2011-01-01

    Full Text Available Objectives : The aim of the present work was to evaluate the in vitro effect of Pleurotus florida extract cataract induced by glucose. Materials and Methods : Goat eye lenses were divided into four groups. Group I lenses were incubated in artificial aqueous humor with glucose concentration 5.5 mM (normal control. Group II lenses were incubated with glucose concentration 55 mM (toxic control. Group III and IV lenses incubated with glucose concentration 55 mM were incubated along with hydroethanolic extract of P. florida 250 μg/ml and 500 μg/ml and subjected to morphological and biochemical evaluation. Results : Group II lenses showed high amount of malondialdehyde (MDA soluble and insoluble protein and decreased catalase and glutathione levels, while lenses treated with P. florida extract showed significant (P < 0.05 reduction in MDA, increased level of catalase (P < 0.001, glutathione (P < 0.005 and total and soluble protein. Conclusions : Hydroethanolic extract of P. florida showed prevention of in vitro glucose induced cataract. Thus, the goat lens model could be used for testing of various anticataract agents.

  11. Ciliary block (malignant) glaucoma after cataract extraction with lens implant treated with YAG laser capsulotomy and anterior hyaloidotomy.

    OpenAIRE

    Halkias, A; Magauran, D M; Joyce, M

    1992-01-01

    An 84-year-old woman developed high intraocular pressure with a shallow anterior chamber 2 months after an extracapsular cataract extraction with posterior chamber lens implant. The condition did not respond to peripheral iridectomy and removal of the implant but was treated successfully with YAG laser capsulotomy and anterior hyaloidotomy.

  12. Effects of L-Carnitine and Cinnamon Extract Treatment on Lens Crystallins of Rats Fed High Fructose Diet

    Directory of Open Access Journals (Sweden)

    Mohamed H. Mahfouz

    2011-01-01

    Full Text Available Problem statement: Rats fed high dietary fructose are documented to form an acquired model of insulin resistance; the present study aims to investigate possible changes in lens crystallins of rats fed high fructose diet and the effects of administration of each exogenous L-Carnitine (CA and Cinnamon Extract (CE on protein glycation, oxidative stress and redox homeostasis in this rat model. Approach: A total number of 60 male Wister rats of body weight 120-160 g were divided into 4 groups of 15 rats each. Group 1 received control diet, while groups 2, 3 and 4: rats received high fructose diet (60g/100 g diet. After 2 weeks from fructose feeding, animals of group 3 were treated with L-carnitine (300 mg g-1 body weight/day i.p., while animals of group 4 were treated with cinnamon extract (0.5 mL/rat/day orally. At the end of experimental period (30 days, serum levels of glucose and insulin were determined. Lenses of each animal were dissected; molecular weights of crystalline, oxidative stress markers, early glycation of lens proteins and carbonyl group were assayed. Results: A significant decline in antioxidants and increase in lipid peroxidation products, protein oxidation and protein glycation were observed in lens samples obtained from fructose-fed rats. Administration of each CA and CE to fructose-fed rats significantly attenuated oxidative damage and protein glycation and returned levels of antioxidants to near those in control group. Chromatographic analysis of lens crystalline of rats fed high fructose diet showed diffused peaks, indicating crystalline aggregation. Conclusion: The results of the present study indicate that dietary fructose disturbs lens integrity and administration of L-carnitine or cinnamon extract may safeguard the lens by minimizing the protein aggregation, preventing glycation and oxidative stress in animals fed high fructose diet. L-carnitine has more potent effects than CE in this animal model.

  13. SURGICAL OUTCOME OF TRIPLE PROCEDURE AS PENETRATING KERATOPLASTY WITH EXTRACAPSULAR CATARACT EXTRACTION WITH POSTERIOR CHAMBER INTRAOCULAR LENS IMPLANTATION IN PATIENTS WITH BOTH CENTRAL CORNEAL OPACITY AND ADVANCED CATARACT AT RURAL SET UP

    OpenAIRE

    Shubhangi Nigwekar, Kishor Badhe, Neeta Misra, Surekha Bangal

    2015-01-01

    Purpose: To study the surgical outcome of triple procedure as penetrating keratoplasty (PKP) with conventional extra capsular cataract extraction (ECCE) with posterior chamber intraocular lens (PCIOL) implantation in patients with both central corneal opacity and advanced cataract at rural set up. Introduction: When corneal opacity and cataract present together then well-established and effective triple procedure is indicated. Prognosis for a clear graft is good in triple, as graft endothe...

  14. Preventative effects of Ginkgo biloba extract (EGb761) on high glucose-cultured opacity of rat lens.

    Science.gov (United States)

    Lu, Qian; Yang, Tingting; Zhang, Mingzhu; Du, Lei; Liu, Ling; Zhang, Nan; Guo, Hao; Zhang, Fan; Hu, Gang; Yin, Xiaoxing

    2014-05-01

    Diabetic cataract is one of the earliest secondary complications of diabetes, and it is characterized by opacification of the eye lens. In this study, we examined the protective effects of Ginkgo biloba extract (EGb761) on rat lenses cultured in high-glucose conditions. The cultured rat lenses were divided into six groups: normal group, high-glucose group, high glucose plus low, medium, and high concentrations of EGb761 groups, and a high glucose plus bendazac lysine group. The activities of antioxidases, aldose reductase, advanced glycosylation end products, transforming growth factor-β2, Smad2/3, E-cadherin, and α-smooth muscle actin were assessed by different methods. Compared with the levels in the high glucose group, EGb761 decreased the intensity of oxidative stress, decreased aldose reductase activation and the level of advanced glycosylation end products, and suppress the transforming growth factor-β2 or Smad pathway activation, further increase the expression of E-cadherin and decrease α-smooth muscle actin, and therefore, prevents the pathological changes of high glucose-induced lens epithelial cells and ameliorated lens opacity. These results suggest that EGb761 has protective effects on several pharmacological targets in the progress of diabetic cataract and is a potential drug for the prevention of diabetic cataract.

  15. Laser induced-thermal lens spectrometry after cloud point extraction for the determination of trace amounts of palladium

    Science.gov (United States)

    Shokoufi, N.; Shemirani, F.; Shokoufi, M.

    2009-10-01

    Cloud point extraction (CPE) in combination with thermal lens spectrometry (TLS) has been developed for the preconcentration and determination of palladium. TLS and CPE methods have good matching conditions for the combination because TLS is a suitable method for the analysis of low volume samples obtained after CPE. Palladium was complexed with 1-(2-pyridylazo)-2-naphthol (PAN) as a complexing agent in an aqueous medium and concentrated by octylphenoxypolyethoxyethanol (Triton X-114) as a surfactant. After the phase separation at 60 °C based on the cloud point extraction of the mixture, the surfactant-rich phase was dried and the remaining phase was dissolved using 20 μL of carbon tetrachloride. The obtained solution was introduced into a quartz microcell and the analyte was determined by laser induced-thermal lens spectrometry (LI-TLS). The single-laser TLS was used as a sensitive method for the determination of palladium-PAN complex in 20 μL of the sample. Under optimum conditions, the analytical curve was linear for the concentration range of 0.3-60 ng mL -1 and the detection limit was 0.04 ng mL -1. The enhancement factor of 460 was achieved for 10 mL samples containing the analyte and relative standard deviations were lower than 5%. The developed method was successfully applied to the extraction and determination of palladium in water samples.

  16. Extracting Leaf Area Index by Sunlit Foliage Component from Downward-Looking Digital Photography under Clear-Sky Conditions

    Directory of Open Access Journals (Sweden)

    Yelu Zeng

    2015-10-01

    Full Text Available The development of near-surface remote sensing requires the accurate extraction of leaf area index (LAI from networked digital cameras under all illumination conditions. The widely used directional gap fraction model is more suitable for overcast conditions due to the difficulty to discriminate the shaded foliage from the shadowed parts of images acquired on sunny days. In this study, a new LAI extraction method by the sunlit foliage component from downward-looking digital photography under clear-sky conditions is proposed. In this method, the sunlit foliage component was extracted by an automated image classification algorithm named LAB2, the clumping index was estimated by a path length distribution-based method, the LAD and G function were quantified by leveled digital images and, eventually, the LAI was obtained by introducing a geometric-optical (GO model which can quantify the sunlit foliage proportion. The proposed method was evaluated at the YJP site, Canada, by the 3D realistic structural scene constructed based on the field measurements. Results suggest that the LAB2 algorithm makes it possible for the automated image processing and the accurate sunlit foliage extraction with the minimum overall accuracy of 91.4%. The widely-used finite-length method tends to underestimate the clumping index, while the path length distribution-based method can reduce the relative error (RE from 7.8% to 6.6%. Using the directional gap fraction model under sunny conditions can lead to an underestimation of LAI by (1.61; 55.9%, which was significantly outside the accuracy requirement (0.5; 20% by the Global Climate Observation System (GCOS. The proposed LAI extraction method has an RMSE of 0.35 and an RE of 11.4% under sunny conditions, which can meet the accuracy requirement of the GCOS. This method relaxes the required diffuse illumination conditions for the digital photography, and can be applied to extract LAI from downward-looking webcam images

  17. Antioxidant activity and phenolic compositions of lentil (Lens culinaris var. Morton) extract and its fractions

    OpenAIRE

    Zou, Yanping; Chang, Sam K.C.; Gu, Yan; Qian, Steven Y.

    2011-01-01

    Phenolic compounds were extracted from Morton lentils using acidified aqueous acetone. The crude Morton extract (CME) was applied onto a macroresin column and desorbed by aqueous methanol to obtain a semi-purified Morton extract (SPME). The SPME was further fractionated over Sephadex LH-20 column into five main fractions (Fr I – Fr V). The phytochemical contents such as total phenolic content (TPC), total flavonoid content (TFC), and condensed tannin content (CTC) of the CME, SPME, and its fr...

  18. Micro/nano-hybrid lens for enhancing light extraction using micro-milling and anodic aluminium oxide (AAO)

    International Nuclear Information System (INIS)

    In the recent past there has been much research towards increasing the transmission of light in optical systems by reducing the Fresnel reflection of radiation, as the reflection of light from surfaces seriously decreases the performance of an optical device. These drawbacks have been overcome by mainly two methods, which are anti-reflective coating and anti-reflective nanostructure formation. In this study, we developed a simple fabrication process for Al micro/nano hybrid lens (MNHL) moulds for efficient light extraction using micro-milling and anodic aluminum oxide (AAO). From these moulds, two different types of polymer MNHL were fabricated using hot-embossing; one was a polymer MNHL that was covered with nanostructures over the entire surface, and the other was one for which only the microlens surface was covered with nanostructures. Two different types of polymer MNHLs were evaluated and compared with each other concerning the light extraction performance. The MNHL with nanostructures only on the microlens surface exhibited a higher light extraction performance than the other by 20.7%. It is expected that the fabricated MNHL can be used for the amplification of small signals when observing the presence of bio-molecules dyed with a fluorescent material. (paper)

  19. Audit of exracapsular cataract extraction with posterior chamber intraocular lens implantation in a tertiary eye care center in Ethiopia.

    Science.gov (United States)

    Tilahun, Yonas; Sisay, Alemayehu

    2006-01-01

    A retrospective audit of records of 370 eyes of 315 patients for whom extracapsular cataract extraction with posterior chamber intraocular lens implantation (ECCE-PC IOL) was performed between 1998 and 1999 was made to determine postoperative visual outcome and complications. One hundred and ninety three patients were males and one hundred and seventy seven were females making a male to female ratio of 1:0.9. At two months postoperatively 82 (30.4%) of eyes had uncorrected visual acuity of 6/18 or better; while 176 (53.7%) of eyes attained an uncorrected visual acuity between 6/18 and 6/60, and 31 (11.5%) had visual acuity between 3/60 and 6/60. 340 of 358 (94.9%) had a preoperative visual acuity of < 3/60. As a result of the surgery, the percentage of blind eyes dropped from 94.9% to 4.4%. The commonest intra operative and early postoperative complications encountered were posterior capsular tear with vitreous loss (5.7%) and striate keratopathy (11.1%) respectively. Posterior capsular opacity was documented in 17 (4.6%) eyes as a late postoperative complication. Routine biometry, to calculate Intra ocular Lens (IOL) power was not done and this was the major limitation of the study. In conclusion, the study increases awareness of cataract surgery outcomes and provides a feedback to achieve better results both in terms of quality and quantity in cataract surgery. Further study with biometric measurement is recommended. PMID:17447364

  20. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  1. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Mike A. (Albuquerque, NM); Foreman, Larry R. (Los Alamos, NM)

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  2. Distributions and Losses of Logging Residues at Clear-Felled Areas during Extraction for Bioenergy: Comparing Dried- and Fresh-Stacked Method

    Directory of Open Access Journals (Sweden)

    Bengt Nilsson

    2015-11-01

    Full Text Available It is well known that a large proportion of available logging residues intended for extraction will not reach the energy-conversion industry, because some are lost during transportation or left on the clear-felled area. However, there is little understanding of where logging residue losses occur in the supply chain. In this study, the distribution of logging residues for two methods (dried- and fresh-stacked method to extract logging residues were studied in one clear-felled area. In addition, residue fractions were examined in a detailed comparison. Even though the fresh-stacked method left somewhat more logging residues at the clear-felled area, the differences are small between the methods. Approximately 30% of the total amount of logging residues was left behind between the harvester heaps, with an additional 10%–15% under these heaps and approximately 2%–3% beneath the windrows. The final product that was delivered to the energy-conversion industry was very similar, regardless of the extraction method used. The delivered chipped logging residues had moisture contents of 37% and 36% following fresh- and dried-stacked methods respectively, and in both cases the needle content in the processed logging residues was approximately 10%. However, the total amount of fine fractions (needles and fines was slightly higher following dried-stacking.

  3. Extracting structural and functional features of widely distributed biological circuits with single cell resolution via tissue clearing and delivery vectors.

    Science.gov (United States)

    Treweek, Jennifer Brooke; Gradinaru, Viviana

    2016-08-01

    The scientific community has learned a great deal from imaging small and naturally transparent organisms such as nematodes and zebrafish. The consequences of genetic mutations on their organ development and survival can be visualized easily and with high-throughput at the organism-wide scale. In contrast, three-dimensional information is less accessible in mammalian subjects because the heterogeneity of light-scattering tissue elements renders their organs opaque. Likewise, genetically labeling desired circuits across mammalian bodies is prohibitively slow and costly via the transgenic route. Emerging breakthroughs in viral vector engineering, genome editing tools, and tissue clearing can render larger opaque organisms genetically tractable and transparent for whole-organ cell phenotyping, tract tracing and imaging at depth. PMID:27393829

  4. Application of thermal lens response to monitor health status of red blood cells: A quantitative study of the cell death process by extracting thermal diffusivity and size

    Science.gov (United States)

    Vasudevan, Srivathsan; Chen, George Chung Kit; Andika, Marta

    2010-03-01

    We explore monitoring the death process of individual red blood cells (RBC) quantitatively by using thermal lens (TL) response. TL response is a noninvasive excitation/probe technique that reflects photothermal parameters (e.g., absorption, thermal diffusivity, size, etc.). Since these parameters of cells change significantly during certain biological processes, real-time TL response was performed to monitor RBC death process when incubated with ionomycin. Theoretical model developed was applied to curve-fit the TL response for extracting thermal diffusivity and size of cells. Thermal diffusivity of dying RBC is found increased by 1.7 times in comparison with healthy cell.

  5. SNOW CLEARING

    CERN Multimedia

    Groupe de Transport/Transport Group

    1999-01-01

    In order to facilitate snow-clearing operations, which commence at 4.30 every morning, drivers of CERN vehicles are kindly requested to group their cars together in the car parks. This will greatly help us in our work. Thank you for your co-operation.Transport Group / ST-HMTel. 72202

  6. Combined ab interno trabeculotomy and lens extraction: a novel management option for combined uveitic and chronic narrow angle raised intraocular pressure.

    Science.gov (United States)

    Lin, Siying; Gupta, Bhaskar; Rossiter, Jonathan

    2016-02-01

    Minimally invasive glaucoma surgery is a developing area that has the potential to replace traditional glaucoma surgery, with its known risk profile, but at present there are no randomised controlled data to validate its use. We report on a case where sequential bilateral combined ab interno trabeculotomy and lens extraction surgery was performed on a 45-year-old woman with combined uveitic and chronic narrow angle raised intraocular pressure. Maximal medical management alone could not control the intraocular pressure. At 12-month follow-up, the patient had achieved stable intraocular pressure in both eyes on a combination of topical ocular antiglaucomatous and steroid therapies. This case demonstrates the effectiveness of trabecular meshwork ablation via ab interno trabeculotomy in a case of complex mixed mechanism glaucoma.

  7. SURGICAL OUTCOME OF TRIPLE PROCEDURE AS PENETRATING KERATOPLASTY WITH EXTRACAPSULAR CATARACT EXTRACTION WITH POSTERIOR CHAMBER INTRAOCULAR LENS IMPLANTATION IN PATIENTS WITH BOTH CENTRAL CORNEAL OPACITY AND ADVANCED CATARACT AT RURAL SET UP

    Directory of Open Access Journals (Sweden)

    Shubhangi Nigwekar, Kishor Badhe, Neeta Misra, Surekha Bangal

    2015-10-01

    Full Text Available Purpose: To study the surgical outcome of triple procedure as penetrating keratoplasty (PKP with conventional extra capsular cataract extraction (ECCE with posterior chamber intraocular lens (PCIOL implantation in patients with both central corneal opacity and advanced cataract at rural set up. Introduction: When corneal opacity and cataract present together then well-established and effective triple procedure is indicated. Prognosis for a clear graft is good in triple, as graft endothelium does not touch the hard nucleus which may occur in two steps or sequential surgery. It provides faster visual rehabilitation. Being single step procedure it reduces patient’s hospital stay, postoperative care and follows up visits. Methodology: In this hospital based observational , three years longitudinal study, we studied the surgical outcome of relatively rare one step triple procedure as PKP with conventional ECCE with PCIOL implantation in sulcus or in bag, in patients with both central corneal opacity and advanced cataract at rural set up. The outcome measures included graft clarity on slit lamp, postoperative unaided visual acuity with Snellen’s chart and the occurrence of postoperative complications after taking IEC permission and informed written consent in local language from study patients. Results: Out of 13 study patients mean age was 61.15yrs (Range50-80yrs. Follow up range was 9-34 months. At final follow up 9 patients (69.23% had clear grafts and 61.52% patients gained visual acuity >6/24. Graft failure was the most common post operative complication in 30.76% followed by Posterior capsular opacification (PCO in 15.38% patients which was treated well with YAG laser capsulotomy. Conclusion: Triple procedure gives good results in respect to graft clarity, unaided vision, and faster rehabilitation.

  8. Study of preparations of bee pollen extracts, antioxidant and antibacterial activity Estudo das preparações de extratos de pólen apícola, atividade antioxidante e antibacteriana

    Directory of Open Access Journals (Sweden)

    Solange Teresinha Carpes

    2007-12-01

    Full Text Available The aim of this study was to determine the antioxidant activity, phenolic content and antibacterial activity of pollen extracts obtained with different concentrations of ethanol. Each extraction condition (ethanol solutions from 40 to 90% had a different effect in the phenolic compounds content. Although, the pollen extract obtained at 60, 70 and 80% of ethanol showed relatively higher levels of phenolic compounds (>10 mg/g and did not present statistical significant difference between the extraction conditions. The amount of total phenolics ranged from 3.6 to 8.1 and 6.6 to 10.9 mg GAE/g for Alagoas state and Parana state pollen, respectively. The higher value for antioxidant activity index was 83.30% for the pollen from Alagoas state and 81.15 % for Parana state pollen. The highest degree of antioxidant activity was found in the extraction at 60% of ethanol solution for Parana state pollen, which also showed the highest concentration of polyphenol compounds. Staphylococcus aureus was inhibited by the ethanolic extract of Alagoas state pollen in all the concentrations of solvent, except the ethanolic extract of pollen at 90%. The extract at 60% of ethanol solution (Parana sample inhibited Bacillus subtilis, Pseudomonas aeruginosa and Klebsiella sp.Objetivou-se, neste estudo determinar compostos fenólicos, a atividade antioxidante a antibacteriana dos extratos etanólicos de pólen, obtidos com diferentes concentrações de etanol. As diferentes condições de extração (etanol de 40 a 90% apresentaram diferentes efeitos no conteúdo dos compostos fenólicos extraídos. Os extratos de pólen obtidos com etanol a 60, 70 e 80% apresentaram maiores níveis de compostos fenólicos (>10 mg/g e não apresentaram diferenças estatísticas entre essas condições de extração. A quantidade de compostos fenólicos nos extratos de pólen variou de 3.6 a 8.1 e 6.6 a 11 mg de equivalente em ácido gálico por g de pólen (GAE, para os estados de Alagoas

  9. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory of probabil......Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...

  10. Observation of the Effect of Small Incision Extracapsular Cataract Extraction and Intraocular Lens Implantation%探析小切口无缝线白内障囊外摘除加人工晶体植入效果观察

    Institute of Scientific and Technical Information of China (English)

    韩艳秋

    2015-01-01

    目的:探讨小切口无缝线白内障囊外摘除加人工晶体植入的效果。方法白内障患者65例,对照组患者使用大切口白内障囊外摘除加人工晶体植入术进行治疗,观察组患者使用小切口无缝线白内障囊外摘除加人工晶体植入术进行治疗。结果经过治疗后,观察组患者的效果明显优于对照组患者,P<0.05。结论小切口无缝线白内障囊外摘除加人工晶体植入在治疗白内障中具有良好的效果。%ObjectiveTo investigate the small incision without suture cataract extracapsular extraction and intraocular lens implantation. Methods65 cases of cataract patients, patients in the control group using a large incision extracapsular cataract extraction and intraocular lens implantation for treatment, patients in the observation group using small incision extracapsular cataract extraction and intraocular lens implantation for treatment.Results after treatment, the effect of observation group of patients is better than the control group,P<0.05.Conclusion Small incision without suture cataract extracapsular extraction and intraocular lens implantation in the treatment of cataract has good effect.

  11. Double-mirror peripheral vitrectomy lens.

    Science.gov (United States)

    Ohji, M; Tano, Y

    1995-11-01

    Many surgeons use prism lenses to see the periphery of the fundus during vitrectomy; however, chromatic aberrations in higher-power prismatic lenses cause blurring of the peripheral image. For better visualization of the periphery of the fundus, we developed a new contact lens, the double-mirror peripheral vitrectomy lens. The new lens is a quartz cylinder with two mirrors, and it provides a crisp, clear, upright image of much more of the peripheral fundus than is visible through conventional prism lenses. The new lens also provides a wider area of view than conventional prism lenses. PMID:7487611

  12. Phakic Pattern Pseudoexfoliation Material Accumulation on Intraocular Lens Surface

    Directory of Open Access Journals (Sweden)

    Emre Güler

    2014-03-01

    Full Text Available Pseudophakic pseudoexfoliation is the accumulation of pseudoexfoliation material on the intraocular lens. Most of the cases have showed scattered flecks of pseudoexfoliation material on the surface of the intraocular lens. However, the phakic pattern consisting of classic three-zone on the intraocular lens is rarely observed. In this case report, we describe a phakic pattern pseudoexfoliation material on the intraocular lens surface 8 years after cataract extraction. (Turk J Ophthalmol 2014; 44: 156-7

  13. Phakic Pattern Pseudoexfoliation Material Accumulation on Intraocular Lens Surface

    OpenAIRE

    Emre Güler; Aylin Tenlik; Tuba Kara Akyüz

    2014-01-01

    Pseudophakic pseudoexfoliation is the accumulation of pseudoexfoliation material on the intraocular lens. Most of the cases have showed scattered flecks of pseudoexfoliation material on the surface of the intraocular lens. However, the phakic pattern consisting of classic three-zone on the intraocular lens is rarely observed. In this case report, we describe a phakic pattern pseudoexfoliation material on the intraocular lens surface 8 years after cataract extraction. (Turk J Ophthalm...

  14. 小切口白内障摘除联合人工晶体植入术52例临床分析%Clinical analysis of 52 cases of small incision cataract extraction combined with intraocular lens implantation

    Institute of Scientific and Technical Information of China (English)

    阿西木

    2014-01-01

    目的:对小切口白内障摘除联合人工晶体植入术的临床疗效进行分析。方法选取我院52例白内障患者为例,所有患者均实施小切口白内障摘除联合人工晶体植入术进行治疗,观察和分析患者的手术治疗效果。结果患者术后显示视力水平有所改善,并发症患者经过处理均全部治愈。结论采用小切口白内障摘除联合人工晶体植入术对白内障患者进行治疗,创伤性小,治疗效果显著,安全性高,值得推广和普及。%Objective The clinical efficacy of small incision cataract extraction and intraocular lens implantation for analysis. Methods 52 cases of cataract patients in our hospital, for example, all patients were implementing small incision cataract extraction and intraocular lens implantation for treatment, observation and analysis of surgical treatment of patients. Results Postoperative patients showed improvement in visual acuity and complications in patients treated were cured. Conclusion the use of small incision cataract extraction and intraocular lens implantation for cataract treatment, traumatic small, significant treatment effect, safe, worthy of promotion and popularization.

  15. Algorithm design of liquid lens inspection system

    Science.gov (United States)

    Hsieh, Lu-Lin; Wang, Chun-Chieh

    2008-08-01

    In mobile lens domain, the glass lens is often to be applied in high-resolution requirement situation; but the glass zoom lens needs to be collocated with movable machinery and voice-coil motor, which usually arises some space limits in minimum design. In high level molding component technology development, the appearance of liquid lens has become the focus of mobile phone and digital camera companies. The liquid lens sets with solid optical lens and driving circuit has replaced the original components. As a result, the volume requirement is decreased to merely 50% of the original design. Besides, with the high focus adjusting speed, low energy requirement, high durability, and low-cost manufacturing process, the liquid lens shows advantages in the competitive market. In the past, authors only need to inspect the scrape defect made by external force for the glass lens. As to the liquid lens, authors need to inspect the state of four different structural layers due to the different design and structure. In this paper, authors apply machine vision and digital image processing technology to administer inspections in the particular layer according to the needs of users. According to our experiment results, the algorithm proposed can automatically delete non-focus background, extract the region of interest, find out and analyze the defects efficiently in the particular layer. In the future, authors will combine the algorithm of the system with automatic-focus technology to implement the inside inspection based on the product inspective demands.

  16. Contact lens in keratoconus

    Directory of Open Access Journals (Sweden)

    Varsha M Rathi

    2013-01-01

    Full Text Available Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP lenses, soft and soft toric lenses, piggy back contact lenses (PBCL, hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL.

  17. Clear evidence of carcinogenic activity by a whole-leaf extract of Aloe barbadensis miller (aloe vera) in F344/N rats.

    Science.gov (United States)

    Boudreau, Mary D; Mellick, Paul W; Olson, Greg R; Felton, Robert P; Thorn, Brett T; Beland, Frederick A

    2013-01-01

    Aloe barbadensis Miller (Aloe vera) is an herbal remedy promoted to treat a variety of illnesses; however, only limited data are available on the safety of this dietary supplement. Drinking water exposure of F344/N rats and B6C3F1 mice to an Aloe vera whole-leaf extract (1, 2, and 3%) for 13 weeks resulted in goblet cell hyperplasia of the large intestine in both species. Based upon this observation, 2-year drinking water studies were conducted to assess the carcinogenic potential of an Aloe vera whole-leaf extract when administered to F344/N rats (48 per sex per group) at 0.5, 1, and 1.5%, and B6C3F1 mice (48 per sex per group) at 1, 2, and 3%. Compared with controls, survival was decreased in the 1.5% dose group of female rats. Treatment-related neoplasms and nonneoplastic lesions in both species were confined primarily to the large intestine. Incidences of adenomas and/or carcinomas of the ileo-cecal and cecal-colic junction, cecum, and ascending and transverse colon were significantly higher than controls in male and female rats in the 1 and 1.5% dose groups. There were no neoplasms of the large intestine in mice or in the 0 or 0.5% dose groups of rats. Increased incidences of mucosa hyperplasia of the large intestine were observed in F344/N rats, and increased incidences of goblet cell hyperplasia of the large intestine occurred in B6C3F1 mice. These results indicate that Aloe vera whole-leaf extract is an intestinal irritant in F344/N rats and B6C3F1 mice and a carcinogen of the large intestine in F344/N rats.

  18. Clear Evidence of Carcinogenic Activity by a Whole-Leaf Extract of Aloe barbadensis Miller (Aloe vera) in F344/N Rats

    OpenAIRE

    Boudreau, Mary D.; Mellick, Paul W.; Olson, Greg R.; Felton, Robert P.; Thorn, Brett T.; Beland, Frederick A.

    2012-01-01

    Aloe barbadensis Miller (Aloe vera) is an herbal remedy promoted to treat a variety of illnesses; however, only limited data are available on the safety of this dietary supplement. Drinking water exposure of F344/N rats and B6C3F1 mice to an Aloe vera whole-leaf extract (1, 2, and 3%) for 13 weeks resulted in goblet cell hyperplasia of the large intestine in both species. Based upon this observation, 2-year drinking water studies were conducted to assess the carcinogenic potential of an Aloe ...

  19. Restoring lens capsule integrity enhances lens regeneration in New Zealand albino rabbits and cats.

    Science.gov (United States)

    Gwon, A; Gruber, L J; Mantras, C

    1993-11-01

    In studies conducted by numerous investigators for 150 years, lenses regenerated following endocapsular lens extraction in New Zealand albino rabbits have been irregular in shape, appearing primarily doughnut-shaped as a result of lack of lens growth at the site of the anterior capsulotomy and its adhesion to the posterior capsule. In the present study, we restored the lens capsule integrity by inserting a collagen patch at the time of surgery to seal the anterior capsulotomy and to improve the shape and structure of the regenerated lenses. We then filled the capsule bag with air to prevent adhesions between the anterior and posterior capsule and maintain capsule tautness and shape. Lens regeneration was first noted as early as one to two weeks. Regenerated lens filled approximately 50% of the capsule bag at two weeks and 100% by five weeks. Subsequent growth was in the anterior-posterior direction and measured by A-scan biometry. Lens thickness increased by 0.3 mm per month. The regenerated lenses were spherical with normal cortical structure and a nuclear opacity. In conclusion, restoration of lens capsular integrity with a collagen patch following endocapsular lens extraction enhanced the shape, structure, and growth rate of the regenerated lenses. In addition, lens regeneration was shown to occur in two cats.

  20. Clinical analysis of HIV positive patients cataract extraction and intraocular lens implantation%人类免疫缺陷病毒阳性者白内障手术临床观察

    Institute of Scientific and Technical Information of China (English)

    马建黎; 臧新莲; 闫珺

    2013-01-01

    目的 探讨人类免疫缺陷病毒(HIV)阳性患者白内障手术的疗效与安全性.方法 HIV阳性者16例(16眼)行白内障摘出人工晶状体植入术的疗效及安全性,进行回顾分析.结果 术后视力<0.1者2眼.0.1 ~0.5者9眼,>0.5者5眼.结论 HIV阳性患者行白内障摘出人工晶状体植入术安全、有效.%Objective To observe the results and safety of catarat surger in HIV positive patients.Methods In the surgery of cataract treatment from october.2007 to December.2011,the treating results and safety of 16 cases (16 eyes) of HIV positive patients cataract extraction and intraocular lens implantation were retrospectively studied.Results 2 cases (2 eyes) of whose vision were less than 0.1 after surgery.9 cases (9 eyes) of whose visual acuity were between 0.1 and 0.5.5 cases (5 eyes) of whose visual acuity were higher than 0.5.Conclusion HIV positive patients cataract extraction and intraocular lens implantation are safe and effective.

  1. 热水萃取法生产澄清香蕉汁的研究%Study on Processing of Clear Banana Juice Using Hot Water Extraction Method

    Institute of Scientific and Technical Information of China (English)

    郑欣; 余元善; 吴继军; 徐玉娟; 肖更生; 黄婉华; 温靖

    2014-01-01

    In this study, the effects of hot water temperature on clarity, total soluble solids, polyphenol oxidase (PPO) and color of banana juice during hot water ex-traction were discussed based on the theory in which heat treatment might induce the pectin and protein in banana pulp to form insoluble products. The results showed the hot water temperature had a significant effect on the formation of insol-uble polymers in banana pulp from pectin and protein. In 75 ℃ water, the pectin and protein in banana pulp were most inclined to form insoluble products. Under this condition, the clarity of banana juice was also highest. The light transmittance at 660 nm was close to 90%. In the banana juice, extracted by 75 ℃ water, the pectin and protein contents were lowest, and they were lower than 7.3 mg/100 ml and 12.9 mg/100 ml respectively. The 75 ℃ water could not inactivate completely the pectin in banana pulp due to its high heat resistance, Therefore, 0.05% L-cys-teine or ascorbic acid needed to be added into banana pulp to inhibit the browning of juice induced by residual PPO.%基于热处理可能诱导香蕉果肉中果胶和蛋白质形成水不溶物的理论,研究了热水萃取温度对香蕉汁澄清度、可溶性固形物含量、多酚氧化酶(PPO)和色泽的影响。结果发现,热水温度对香蕉果肉中果胶和蛋白质形成水不溶性聚合物的能力有显著的影响,其中75℃的热水萃取诱导香蕉果肉中果胶和蛋白质形成水不溶物的能力最强,获得香蕉汁的澄清度最高,其透光率(660 nm)接近90%;75℃热水萃取获得的香蕉汁的果胶和蛋白含量最低,分别低于每100 ml 香蕉汁7.3和12.9 mg。由于香蕉果肉中 PPO耐热性强,75℃的热水萃取难以将其完全失活,为防止在香蕉果肉中的 PPO在香蕉汁打浆期间引起酶促褐变,需添加0.05%的 L-半胱氨酸或抗坏血酸进行护色。

  2. Biologically inspired LED lens from cuticular nanostructures of firefly lantern.

    Science.gov (United States)

    Kim, Jae-Jun; Lee, Youngseop; Kim, Ha Gon; Choi, Ki-Ju; Kweon, Hee-Seok; Park, Seongchong; Jeong, Ki-Hun

    2012-11-13

    Cuticular nanostructures found in insects effectively manage light for light polarization, structural color, or optical index matching within an ultrathin natural scale. These nanostructures are mainly dedicated to manage incoming light and recently inspired many imaging and display applications. A bioluminescent organ, such as a firefly lantern, helps to out-couple light from the body in a highly efficient fashion for delivering strong optical signals in sexual communication. However, the cuticular nanostructures, except the light-producing reactions, have not been well investigated for physical principles and engineering biomimetics. Here we report a unique observation of high-transmission nanostructures on a firefly lantern and its biological inspiration for highly efficient LED illumination. Both numerical and experimental results clearly reveal high transmission through the nanostructures inspired from the lantern cuticle. The nanostructures on an LED lens surface were fabricated by using a large-area nanotemplating and reconfigurable nanomolding with heat-induced shear thinning. The biologically inspired LED lens, distinct from a smooth surface lens, substantially increases light transmission over visible ranges, comparable to conventional antireflection coating. This biological inspiration can offer new opportunities for increasing the light extraction efficiency of high-power LED packages.

  3. Contact Lens Solution Toxicity

    Science.gov (United States)

    ... rash and rashes clinical tools newsletter | contact Share | Contact Lens Solution Toxicity Information for adults A A A This image shows a reaction to contact lens solution. The prominent blood vessels and redness ...

  4. Prognóstico visual para facectomia: retinômetro de Heine e orifício estenopéico múltiplo Visual prognosis for lens extraction: heine retinometer and multiple pinhole

    Directory of Open Access Journals (Sweden)

    Frederico Augusto Costa Reis

    2004-10-01

    Full Text Available OBJETIVO: Avaliar a acurácia do retinômetro de Heine e do orifício estenopéico múltiplo no prognóstico da acuidade visual pós-facectomia. MÉTODOS: Foram examinados 65 olhos com o retinômetro de Heine e com o orifício estenopéico múltiplo. Após a facectomia os pacientes foram submetidos à refração e os resultados comparados com a previsão dos instrumentos. O grupo 1 é formado por pacientes com acuidade visual pior que 20/100 e o grupo 2 melhor ou igual a 20/100. RESULTADO: O retinômetro de Heine teve bons resultados em 21% e 44%, nos grupos 1 e 2 respectivamente. O orifício estenopéico múltiplo teve bons resultados em 26% e 52%, nos grupos 1 e 2 respectivamente. CONCLUSÃO: O retinômetro de Heine tem acurácia semelhante ao orifício estenopéico múltiplo no prognóstico da acuidade visual pós-facectomia. Os instrumentos não devem ser usados para contra-indicar a facectomia devido ao grande número de resultados falso-negativos.PURPOSE: To evaluate Heine retinometer and multiple pinhole accuracy in the prognosis of the visual acuity after lens extraction. METHODS: 65 eyes were examined with Heine retinometer and with multiple pinhole. After surgery the patients were submitted to refraction and the result were compared with the prediction by the instruments. Group 1 is formed of patients with visual acuity worse than 20/100 and group 2, better or equal to 20/100. RESULTS: The Heine retinometer obtained good results in 21% and 44% of patients in both groups (1 and 2 respectively. The multiple pinhole had good results in 26% and 52% of patients concerning both groups (1 and 2 respectively. CONCLUSION: The Heine retinometer has an accuracy similar to the multiple pinhole in the prognosis of visual acuity after lens extraction. The instruments should not be used to contraindicate lens extraction due to the large number of false negative results.

  5. Observations on the relationship between the levels of serum IL-6 and TNF-α and the severity of diabetic retinopathy and curative effect in cataract extraction with intraocular lens implantation in diabetics

    International Nuclear Information System (INIS)

    Objective: To determine the sequential changes of blood levels of interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) in diabetics with extracapsular extraction and posterior chamber intraocular lens implantation and to study their correlation with curative effects and pos-operative complications. Methods: The serum concentrations of IL-6 and TNF-α in 39 diabetics and non-diabetics were measured by radioimmunoassay at preoperative, post-operative and on days 7, 14 and 90 postoperatively. Results: There was significant difference in the levels of the two factors between the diabetic group and non-diabetic group preoperatively (P<0.05). The serum levels of the two factors in patients with proliferative diabetic retinopathy were higher than those in non-diabetic retinopathy, and simple diabetic retinopathy post-operative (P<0.01). Post-operative complication rate was higher in patients with proliferative diabetic retinopathy than those without retinopathy and those having simple diabetic retinopathy. Conclusion: The levels of the two factors correlate with complications and curative effect of patients with proliferative diabetic retinopathy undergoing intraocular lens implantation

  6. LensClean revisited

    CERN Document Server

    Wucknitz, O

    2004-01-01

    We discuss the LensClean algorithm which for a given gravitational lens model fits a source brightness distribution to interferometric radio data in a similar way as standard Clean does in the unlensed case. The lens model parameters can then be varied in order to minimize the residuals and determine the best model for the lens mass distribution. Our variant of this method is improved in order to be useful and stable even for high dynamic range systems with nearly degenerated lens model parameters. Our test case B0218+357 is dominated by two bright images but the information needed to constrain the unknown parameters is provided only by the relatively smooth and weak Einstein ring. The new variant of LensClean is able to fit lens models even in this difficult case. In order to allow the use of general mass models with LensClean, we develop the new method LenTil which inverts the lens equation much more reliably than any other method. This high reliability is essential for the use as part of LensClean. Finally...

  7. Pseudophakic hyperopia in nanophthalmic eyes managed by a posterior chamber implantable collamer lens

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2011-01-01

    Full Text Available We report a case of a bilateral posterior chamber implantable collamer lens (ICL implantation post-clear lens extraction, to reduce the residual hyperopia, in a patient with nanophthalmic eyes. A 30-year-old female patient, keen to reduce her dependency on glasses and contact lenses, came to our refractive surgery department. Her refractive error was +12.0 and +12.5 diopters in the right and left eye, respectively, with steep corneas on keratometry and a shallow anterior chamber depth. She underwent clear lens extraction with implantation of +35.0 D and +40.0 D IOL in the right eye and left eye, respectively. Her post-operative best-corrected visual acuity was 20/30 with +8.5 D in the right eye and +6 D in the left. She underwent bilateral ICL implantation. Postoperatively after 6 months, her unaided visual acuity was 20/30 in both eyes. In conclusion, ICL implantation can be considered to correct residual hypermetropic ametropia in pseudophakic eyes when other options have limitations.

  8. Clearing, transparency, and collateral

    OpenAIRE

    Francesco Carli; Francesca Carapella; Gaetano Antinolfi

    2014-01-01

    In an environment of Over-The-Counter trading with adverse selection we study traders' incentives to screen their counterparties under different clearing arrangements. When the clearing arrangement is also a choice, traders decide which types of transactions to clear under each arrangement, with signicant consequences for transparency and collateral requirements. The key trade-off is between insurance and the value of information: on one hand risk averse traders want to smooth consumption and...

  9. REFRACTIVE NEUTRON LENS

    OpenAIRE

    Petrov, P. V.; Kolchevsky, N.N.

    2013-01-01

    Compound concave refractive lenses are used for focusing neutron beam. Investigations of spectral and focusing properties of a refractive neutron lens are presented. Resolution of the imaging system on the base of refractive neutron lenses depends on material properties and parameters of neutron source. Model of refractive neutron lens are proposed. Results of calculation diffraction resolution and focal depth of refractive neutron lens are discussed.

  10. Len Yi Part 2

    OpenAIRE

    Bsod nams rgyal mtshan

    2011-01-01

    INTRODUCTION: Sonan Jetsun (Bsod nams rgyal mtshan) filmed this material 12-22 January 2008 in Len yi (Lianyi) Village, Sgong po (Gongbo) Township, Sde rong (Derong) County, Dkar mdzes (Ganzi) Tibetan Autonomous Prefecture, Si khron (Sichuan) Province, PR China. The film features the Tibetan New Year, Bkra shis Temple, and ordinary people's lives in Len yi Village. Sonan Jetsun also edited the material and plans to give it to Len yi villagers on DVD/ VCD. LOCATION: Lianyi Village is 200 k...

  11. Iatrogenic Lens Injuries

    Directory of Open Access Journals (Sweden)

    Ümit Kamış

    2012-12-01

    Full Text Available During intraocular surgery, undesired damages of various etiology may occur in adjacent tissues. One of these tissues is the crystalline lens, which may be traumatized both in anterior segment and posterior segment surgeries, and when damaged, it usually causes marked decrease in visual acuity. The leading causes of iatrogenic lens injuries are intravitreal injection, laser iridotomy, phakic intraocular lens implantation, anterior chamber paracentesis, and vitreoretinal surgery. When crystalline lens damage occurs, its negative effect on visual function may be eliminated by performing cataract surgery intraoperatively or in elective conditions. (Turk J Ophthalmol 2012; 42: Supplement 27-30

  12. Lens regeneration in mice under the influence of vitamin A

    Indian Academy of Sciences (India)

    Digvijay Singh Shekhawat; O P Jangir; Acharya Prakash; Suthar Pawan

    2001-12-01

    The effect of vitamin A has been studied on lens regeneration in young (7 days old) as well as adult mice. A longitudinal slit was made under local anesthesia in the cornea over the lens. The lens was extracted intact through the incision. Intraperitonial injection of vitamin A (0.05 ml of 30 IU/ml in young and 0.05 ml of 50 IU/ml in adult) was given to the operated animals. Vitamin A was found to induce lens regeneration in not only young but also in adult mice. Regenerated lenses were similar in shape, size, transparency and histological features to normal intact lenses.

  13. EXTRACT

    DEFF Research Database (Denmark)

    Pafilis, Evangelos; Buttigieg, Pier Luigi; Ferrell, Barbra;

    2016-01-01

    therefore developed an interactive annotation tool, EXTRACT, which helps curators identify and extract standard-compliant terms for annotation of metagenomic records and other samples. Behind its web-based user interface, the system combines published methods for named entity recognition of environment...... and text-mining-assisted curation revealed that EXTRACT speeds up annotation by 15-25% and helps curators to detect terms that would otherwise have been missed.Database URL: https://extract.hcmr.gr/....

  14. Lens auto-centering

    Science.gov (United States)

    Lamontagne, Frédéric; Desnoyers, Nichola; Doucet, Michel; Côté, Patrice; Gauvin, Jonny; Anctil, Geneviève; Tremblay, Mathieu

    2015-09-01

    In a typical optical system, optical elements usually need to be precisely positioned and aligned to perform the correct optical function. This positioning and alignment involves securing the optical element in a holder or mount. Proper centering of an optical element with respect to the holder is a delicate operation that generally requires tight manufacturing tolerances or active alignment, resulting in costly optical assemblies. To optimize optical performance and minimize manufacturing cost, there is a need for a lens mounting method that could relax manufacturing tolerance, reduce assembly time and provide high centering accuracy. This paper presents a patent pending lens mounting method developed at INO that can be compared to the drop-in technique for its simplicity while providing the level of accuracy close to that achievable with techniques using a centering machine (usually innovative auto-centering method is based on the use of geometrical relationship between the lens diameter, the lens radius of curvature and the thread angle of the retaining ring. The autocentering principle and centering test results performed on real optical assemblies are presented. In addition to the low assembly time, high centering accuracy, and environmental robustness, the INO auto-centering method has the advantage of relaxing lens and barrel bore diameter tolerances as well as lens wedge tolerances. The use of this novel lens mounting method significantly reduces manufacturing and assembly costs for high performance optical systems. Large volume productions would especially benefit from this advancement in precision lens mounting, potentially providing a drastic cost reduction.

  15. Superlensing Microscope Objective Lens

    CERN Document Server

    Yan, Bing; Parker, Alan; Lai, Yukun; Thomas, John; Yue, Liyang; Monks, James

    2016-01-01

    Conventional microscope objective lenses are diffraction limited, which means that they cannot resolve features smaller than half the illumination wavelength. Under white light illumination, such resolution limit is about 250-300 nm for an ordinary microscope. In this paper, we demonstrate a new superlensing objective lens which has a resolution of about 100 nm, offering at least two times resolution improvement over conventional objectives in resolution. This is achieved by integrating a conventional microscope objective lens with a superlensing microsphere lens using a 3D printed lens adaptor. The new objective lens was used for label-free super-resolution imaging of 100 nm-sized engineering and biological samples, including a Blu-ray disc sample, semiconductor chip and adenoviruses. Our work creates a solid base for developing a commercially-viable superlens prototype, which has potential to transform the field of optical microscopy and imaging.

  16. Clear cell chondrosarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, R.; David, R.; Cierney, G. III

    1985-01-01

    The clinical, radiologic, and histopathologic features of three cases of clear cell chondrosarcoma are described. On radiographs, this rather benign-appearing tumor resembles a chondroblastoma when it occurs at the end of a long bone, and may occasionally show a calcified matrix. However, it has distinctive tumor cells with a centrally placed vesicular nucleus surrounded by clear cytoplasm. The lesion has a low-grade malignancy and is amenable to en bloc surgical resection, which results in a much better prognosis than that of conventional chondrosarcoma.

  17. Snow-clearing operations

    CERN Document Server

    EN Department

    2010-01-01

    To facilitate snow clearing operations, which commence at 4.30 in the morning, all drivers of CERN cars are kindly requested to park them together in groups. This will help us greatly assist us in our work. Thank-you for your help. Transport Group / EN-HE Tel. 72202

  18. Unitary lens semiconductor device

    Science.gov (United States)

    Lear, Kevin L.

    1997-01-01

    A unitary lens semiconductor device and method. The unitary lens semiconductor device is provided with at least one semiconductor layer having a composition varying in the growth direction for unitarily forming one or more lenses in the semiconductor layer. Unitary lens semiconductor devices may be formed as light-processing devices such as microlenses, and as light-active devices such as light-emitting diodes, photodetectors, resonant-cavity light-emitting diodes, vertical-cavity surface-emitting lasers, and resonant cavity photodetectors.

  19. 婴儿先天性白内障摘除一期人工晶状体植入的研究进展%Primary intraocular lens implantation after extraction of congenital cataract in infants

    Institute of Scientific and Technical Information of China (English)

    刘馨; 罗怡

    2012-01-01

    近年来,婴儿先天性白内障摘除后一期植入人工晶状体受到越来越多眼科医生的认可,并在临床实践中逐步开展.25G玻璃体切除系统在婴儿白内障手术中的应用,大大降低了术后并发症的发生;新型屈光度计算公式和近视漂移预测公式的发展,提高了人工晶状体屈光度选择的准确性;更适合婴幼儿的人工晶状体和弱视训练方法的发展,提升了术后视功能重建的效果.%Primary intraocular lens (IOL) implantation after extraction of congenital cataract in infants has been accepted and gradually applied to clinic by an increasing number of ophthalmologists in recent years.Incidence of postoperative complications has largely reduced after application of the 25-gauge vitrectomy system in cataract surgery in infants.Accuracy of IOL power calculation has been increased because of the developments of new generation of I0L power calculation formula and prediction formula of myopia shift.Visual rehabilitation has improved due to the developments of the infants-suitable IOLs and the means of amblyopia training.

  20. Contact Lens Risks

    Science.gov (United States)

    ... Health and Consumer Devices Consumer Products Contact Lenses Contact Lens Risks Share Tweet Linkedin Pin it More ... redness blurred vision swelling pain Serious Hazards of Contact Lenses Symptoms of eye irritation can indicate a ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Sep 10, 2015 Contact Lens Horror Stories: Poor Care Can Lead to Blindness Sep 09, 2015 How to Correct High Myopia Feb 27, 2015 More Eye Health News Pet Fish Fitted with Fake Eye in ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  4. Clearing the Big Smog

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Beijing is trying to clean up its sky with a new standard for vehicle emissions From March 1,Beijing has imple- mented a new stricter vehicle emission standard that could lead to cleaner air,but also force thousands of cars off the road. StandardⅣ,the latest in a series of measures aimed at clearing the per- sistent smog,will match the current standard of the European Union. All the new light petro vehicles that are on sale in the Beijing market shall

  5. Terahertz Artificial Dielectric Lens

    Science.gov (United States)

    Mendis, Rajind; Nagai, Masaya; Wang, Yiqiu; Karl, Nicholas; Mittleman, Daniel M.

    2016-03-01

    We have designed, fabricated, and experimentally characterized a lens for the THz regime based on artificial dielectrics. These are man-made media that mimic properties of naturally occurring dielectric media, or even manifest properties that cannot generally occur in nature. For example, the well-known dielectric property, the refractive index, which usually has a value greater than unity, can have a value less than unity in an artificial dielectric. For our lens, the artificial-dielectric medium is made up of a parallel stack of 100 μm thick metal plates that form an array of parallel-plate waveguides. The convergent lens has a plano-concave geometry, in contrast to conventional dielectric lenses. Our results demonstrate that this lens is capable of focusing a 2 cm diameter beam to a spot size of 4 mm, at the design frequency of 0.17 THz. The results further demonstrate that the overall power transmission of the lens can be better than certain conventional dielectric lenses commonly used in the THz regime. Intriguingly, we also observe that under certain conditions, the lens boundary demarcated by the discontinuous plate edges actually resembles a smooth continuous surface. These results highlight the importance of this artificial-dielectric technology for the development of future THz-wave devices.

  6. Out-of-the-bag intraocular lens dislocation: outcomes of posterior chamber intraocular lens exchange, risk factors, and prevention

    Institute of Scientific and Technical Information of China (English)

    ZHENG Dan-ying; CHEN Li-na; SUN Yi; SHAO Ying-feng; LIANG Jing-li; LIU Yi-zhi

    2010-01-01

    Background Dislocation of posterior chamber intraocular lens is one of the most common complications of intraocular lens implantation. Lens exchange is an effective solution to this unsatisfactory status. This study was conducted to analyze the possible predisposing factors for out-of-the-bag posterior chamber intraocular lens dislocation and to study the outcomes of lens exchange surgery.Methods Thirty-six consecutive patients (36 eyes) with out-of-the-bag intraocular lens dislocation who underwent posterior chamber intraocular lens exchange in Zhongshan Ophthalmic Center of Sun Yat-sen University (Guangdong,China) from January 2003 to October 2009 were included. A 6-month follow-up was completed. The causes for out-of-the-bag intraocular lens dislocation and visual outcomes of posterior chamber intraocular lens exchange were analyzed. The out-of-the-bag intraocular lens dislocation was diagnosed on the basis of the findings from slit-lamp microscope and B-ultrasound. The dislocated intraocular lens was explanted. Reimplantation of a new posterior chamber intraocular lens was performed in each case using standardized surgical procedures.Results In this study, a total of thirty-six consecutive patients (36 eyes) with out-of-the-bag intraocular lens dislocation underwent posterior chamber intraocular lens exchange surgery. Causes for out-of-the-bag intraocular lens dislocation included posterior capsule rupture during the initial cataract extraction procedure (23 eyes, 63.8%), trauma (5 eyes,13.9%), neodymium-doped yttrium aluminium garnet (Nd:YAG) laser-induced dislocation (2 eyes, 5.6%), the status after vitrectomy (2 eyes, 5.6%) and unidentifiable etiology (4 eyes, 11.1%). Symptoms of these patients mainly included decrease in visual acuity (17 cases, 47.2%), blurred vision (16 cases, 44.4%), glare (1 case, 2.8%), diplopia (1 case,2.8%), and halo (1 case, 2.8%). Intraocular lens dislocation into the posterior vitreous cavity (29 eyes, 80.5%), anterior chamber (1

  7. Changes in Monkey Crystalline Lens Spherical Aberration During Simulated Accommodation in a Lens Stretcher

    Science.gov (United States)

    Maceo Heilman, Bianca; Manns, Fabrice; de Castro, Alberto; Durkee, Heather; Arrieta, Esdras; Marcos, Susana; Parel, Jean-Marie

    2015-01-01

    Purpose. The purpose of this study was to quantify accommodation-induced changes in the spherical aberration of cynomolgus monkey lenses. Methods. Twenty-four lenses from 20 cynomolgus monkeys (Macaca fascicularis; 4.4–16.0 years of age; postmortem time 13.5 ± 13.0 hours) were mounted in a lens stretcher. Lens spherical aberration was measured in the unstretched (accommodated) and stretched (relaxed) states with a laser ray tracing system that delivered 51 equally spaced parallel rays along 1 meridian of the lens over the central 6-mm optical zone. A camera mounted below the lens was used to measure the ray height at multiple positions along the optical axis. For each entrance ray, the change in ray height with axial position was fitted with a third-order polynomial. The effective paraxial focal length and Zernike spherical aberration coefficients corresponding to a 6-mm pupil diameter were extracted from the fitted values. Results. The unstretched lens power decreased with age from 59.3 ± 4.0 diopters (D) for young lenses to 45.7 ± 3.1 D for older lenses. The unstretched lens shifted toward less negative spherical aberration with age, from −6.3 ± 0.7 μm for young lenses to −5.0 ± 0.5 μm for older lenses. The power and spherical aberration of lenses in the stretched state were independent of age, with values of 33.5 ± 3.4 D and −2.6 ± 0.5 μm, respectively. Conclusions. Spherical aberration is negative in cynomolgus monkey lenses and becomes more negative with accommodation. These results are in good agreement with the predicted values using computational ray tracing in a lens model with a reconstructed gradient refractive index. The spherical aberration of the unstretched lens becomes less negative with age. PMID:25670492

  8. Intraocular Lens Calcification; a Clinicopathologic Report

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaei-Kanavi

    2009-04-01

    Full Text Available

    PURPOSE: To describe the clinical and pathological features of a case of hydrogel intraocular lens (IOL calcification. CASE REPORT: A 48-year-old man underwent explantation of a single-piece hydrophilic acrylic intraocular lens in his left eye because of decreased visual acuity and milky white opalescence of the IOL. The opacified lens was exchanged uneventfully with a hydrophobic acrylic IOL. Gross examination of the explanted IOL disclosed opacification of the optic and haptics. Full-thickness sections of the lens optic were stained with hematoxylin and eosin (H&E, von Kossa and Gram Tworts'. Microscopic examination of the sections revealed fine and diffuse basophilic granular deposits of variable size within the lens optic parallel to the lens curvature but separated from the surface by a moderately clear zone. The deposits were of high calcium content as evident by dark brown staining with von Kossa. Gram Tworts' staining disclosed no microorganisms. CONCLUSION: This report further contributes to the existing literature on hydrogel IOL calcification.

  9. Late opacification of a hydrophilic acrylic intraocular lens

    Directory of Open Access Journals (Sweden)

    Al-Bdour Muawyah

    2008-01-01

    Full Text Available Cataract extraction and intraocular lens implantation is considered to be a safe procedure in most cases. However, the new advances in the surgical technique namely phacoemulsification and hence the increased use of foldable intraocular lenses have given rise to new complications including late opacification of intraocular lenses. In this case we report late opacification of a foldable hydrophilic acrylic intraocular lens and the surgical technique for its exchange.

  10. Luneburg lens in silicon photonics

    OpenAIRE

    Di Falco, Andrea; Kehr, Susanne C; Leonhardt, Ulf

    2011-01-01

    The Luneburg lens is an aberration-free lens that focuses light from all directions equally well. We fabricated and tested a Luneburg lens in silicon photonics. Such fully-integrated lenses may become the building blocks of compact Fourier optics on chips. Furthermore, our fabrication technique is sufficiently versatile for making perfect imaging devices on silicon platforms. (C) 2011 Optical Society of America

  11. Flat acoustic lens by acoustic grating with curled slits

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Pai; Xiao, Bingmu; Wu, Ying, E-mail: ying.wu@kaust.edu.sa

    2014-10-03

    We design a flat sub-wavelength lens that can focus acoustic wave. We analytically study the transmission through an acoustic grating with curled slits, which can serve as a material with tunable impedance and refractive index for acoustic waves. The effective parameters rely on the geometry of the slits and are independent of frequency. A flat acoustic focusing lens by such acoustic grating with gradient effective refractive index is designed. The focusing effect is clearly observed in simulations and well predicted by the theory. We demonstrate that despite the large impedance mismatch between the acoustic lens and the matrix, the intensity at the focal point is still high due to Fabry–Perot resonance. - Highlights: • Expression of transmission coefficient of an acoustic grating with curled slits. • Non-dispersive and tunable effective medium parameters for the acoustic grating. • A flat acoustic focusing lens with gradient index by using the acoustic grating.

  12. To Clear or Not To Clear - That Is the Question

    OpenAIRE

    Downing, Adam; Childs, Corey; Porr, C. A. Shea

    2009-01-01

    Many options exist if you do decide to clear land. Regardless of the option you choose, the primary goal should be the same: to minimize soil loss and movement during and immediately after the land clearing process.

  13. Analysis of the efficacy of traumatic cataract extraction and intraocular lens implantation%外伤性白内障摘出人工晶状体植入术效果分析

    Institute of Scientific and Technical Information of China (English)

    田波新

    2015-01-01

    目的:分析外伤性白内障手术摘出人工晶状体植入的手术效果。方法外伤性白内障手术60例(60眼)。其中39例行Ⅰ期IOL植入,21例行Ⅱ期IOL植入。结果Ⅰ期与Ⅱ期IOL植入,手术后视力均有明显提高,两者术后视力提高程度的差异无统计学意义(P=0.230~1.124)。术中并发症主要是后囊破裂及玻璃体脱出,术后并发症有角膜水肿、虹膜睫状体炎和后囊浑浊。结论IOL植入是治疗外伤性白内障,提高视力的有效方法,虽然Ⅰ期IOL植入术后并发症较Ⅱ期人工晶状体植入术后高,但经过及时有效的治疗都能得以恢复,且避免了二次手术。%Objective To analyse the efficacy of traumatic cataract extraction and intraocular lens (IOL)implantation. Methods Sixty eyes of 60 cases of traumatic cataract were enrolled,among which 39 patients received IOL implantation at stage I, and another 21 cases received IOL implantation at stageⅡ. Results After the IOL implantation surgery, the vision of patients in both groups were significantly improved, and the differences in improved vision level between two groups was not statistically significant (P=0. 230 ~1. 124). Additionally,the intraoperative complications were mainly posterior capsule rupture and vitreous loss, while postoperative complications included corneal edema, iridocyclitis, and posterior capsular opacification. Conclusion IOL implantation is an effective way to treat traumatic cataract and improve vision. Although the postoperative complications of IOL implantation at stage I were more than that of stageⅡ,they all could recover after timely and effective treatment which avoid the second surgery.

  14. Use of Digital Image Technology to 'Clearly' Depict Global Change

    Science.gov (United States)

    Molnia, B. F.; Carbo, C. L.

    2014-12-01

    Earth is dynamic and beautiful. Understanding why, when, how, and how fast its surface changes yields information and serves as a source of inspiration. The artistic use of geoscience information can inform the public about what is happening to their planet in a non-confrontational and apolitical way. While individual images may clearly depict a landscape, photographic comparisons are necessary to clearly capture and display annual, decadal, or century-scale impacts of climate and environmental change on Earth's landscapes. After years of effort to artistically communicate geoscience concepts with unenhanced individual photographs or pairs of images, the authors have partnered to maximize this process by using digital image enhancement technology. This is done, not to manipulate the inherent artistic content or information content of the photographs, but to insure that the comparative photo pairs produced are geometrically correct and unambiguous. For comparative photography, information-rich historical photographs are selected from archives, websites, and other sources. After determining the geographic location from which the historical photograph was made, the original site is identified and eventually revisited. There, the historical photos field of view is again photographed, ideally from the original location. From nearly 250 locations revisited, about 175 pairs have been produced. Every effort is made to reoccupy the original historical site. However, vegetation growth, visibility reduction, and co-seismic level change may make this impossible. Also, inherent differences in lens optics, camera construction, and image format may result in differences in the geometry of the new photograph when compared to the old. Upon selection, historical photos are cleaned, contrast stretched, brightness adjusted, and sharpened to maximize site identification and information extraction. To facilitate matching historical and new images, digital files of each are overlain in

  15. 无粘弹剂小切口白内障摘除加人工晶体植入术156例临床疗效观察%Effect of no viscoelastic small incision cataract extraction plus intraocular lens implantation

    Institute of Scientific and Technical Information of China (English)

    庞永明; 尼亚美

    2011-01-01

    Objective To evaluate non-viscoelastic small incision extracapsular cataract extraction plus intraocular lens implantation in cataract surgery on Africans. Methods 156 cases (156 eyes) black cataract patients without viscoelastic were treated with small incision extracapsular cataract extraction plus intraocular lens implantation. Results The visual acuity≥0. 3 after 1 week were 71. 8% (112). The visual acuity ≥1. 0 accounted for 11. 5% (18). The visual acuity ≥0. 3 after 3 months accounted for 93. 6% (146). The visual acuity ≥1. 0 was 15. 4% (24). Conclusion It is effective to treated African cataract with non-viscoelastic small incision extracapsular cataract extraction plus intraocular lens implantation.%目的 探讨无粘弹剂小切口白内障囊外摘除加人工晶体植入术在治疗非洲黑人白内障的临床疗效.方法 对156例(156眼)黑人白内障患者行无粘弹剂小切口白内障囊外摘除加人工晶体植入术,并评估疗效.结果 术后1周视力≥0.3者占71.8%(112眼),视力≥1.0者占11.5%(18眼).3个月后视力≥0.3者占93.6%(146眼),视力≥1.0者占15.4%(24眼).结论 无粘弹剂小切口白内障囊外摘除及人工晶体植入术损伤小,术后视力恢复好.在非洲地区有推广应用价值.

  16. Functional modular contact lens

    Science.gov (United States)

    Shum, Angela J.; Cowan, Melissa; Lähdesmäki, Ilkka; Lingley, Andrew; Otis, Brian; Parviz, Babak A.

    2009-08-01

    Tear fluid offers a potential route for non-invasive sensing of physiological parameters. Utilization of this potential depends on the ability to manufacture sensors that can be placed on the surface of the eye. A contact lens makes a natural platform for such sensors, but contact lens polymers present a challenge for sensor fabrication. This paper describes a microfabrication process for constructing sensors that can be integrated into the structure of a functional contact lens in the future. To demonstrate the capabilities of the process, an amperometric glucose sensor was fabricated on a polymer substrate. The sensor consists of platinum working and counter electrodes, as well as a region of indium-tin oxide (ITO) for glucose oxidase immobilization. An external silver-silver chloride electrode was used as the reference electrode during the characterization experiments. Sensor operation was validated by hydrogen peroxide measurements in the 10- 20 μM range and glucose measurements in the 0.125-20 mM range.

  17. LASER INDUCED THERMAL LENS EFFECT

    Institute of Scientific and Technical Information of China (English)

    沈俊; 黄孟才; 江景云; 施教芳

    1991-01-01

    The thermal lens effect has emerged in recent years as a novel ,highly sensitive tool for the study of the very weak molecular absorption of light energy,This paper discusses the theory and technique of the thermal lens measurement.Some opplications of the thermal lens measurement are described.A mode-mismatched dual-beam thermal lens experimental arragement with a modulated probe beam ,designed by the authors.for trace analysis is presented,and its detection limit was found to be 4.1×10-7 for Cu(Ⅱ) in ethanol and 80 mW excitation power.

  18. Development of lens sutures.

    Science.gov (United States)

    Kuszak, Jer R; Zoltoski, Rebecca K; Tiedemann, Clifford E

    2004-01-01

    Cylindrical map projections (CMPs) have been used for centuries as an effective means of plotting the features of a 3D spheroidal surfaces (e.g. the earth) on a 2D rectangular map. We have used CMPs to plot primate fiber cell organization from selected growth shells as a function of growth, development and aging. Lens structural parameters and features were derived from slit-lamp, light and transmission and scanning electron micrographs. This information was then used to create CMPs of lenses that were then correlated with azimuthal map projections (AMPs; projections that are radially symmetric around a central point [the poles]) to reveal different suture patterns during distinct time periods. In this manner, both lens fiber and suture branch locations are defined by degrees of longitude and latitude. CMPs and AMPs confirm that throughout defined periods of development, growth and ageing, increasingly complex suture patterns are formed by the precise ordering of straight and opposite end curvature fibers. However, the manner in which additional suture branches are formed anteriorly and posteriorly is not identical. Anteriorly, new branches are added between extant branches. Posteriorly, pairs of new branches are formed that progressively overlay extant branches. The advantage of using CMPs is that the shape and organization of every fiber in a growth shell can be observed in a single image. Thus, the use of CMPs to plot primate fiber cell organization has revealed more complex aspects of fiber formation that may explain, at least in part, changes in lens optical quality as a function of age and pathology. In addition, more accurate measurements of fiber length will be possible by incorporating the latitudinal and longitudinal locations of fibers. PMID:15558480

  19. Clinical analysis of delayed onset postoperative uveitis after cataract extraction with intraocular lens implantation%白内障摘出人工晶状体植入术后迟发性葡萄膜炎的临床分析

    Institute of Scientific and Technical Information of China (English)

    赵才; 楚松峰; 王磊

    2011-01-01

    Objective To investigate the pathogenesis and related factors of delayed uveitis after cataract extraction intraocular lens (IOL) implantation surgery.Methods 27 eyes of delayed uveitis in 545 age-related cataract cases,15 cases of delayed uveitis in 92 cases with diabetic cataract,11 cases of delayed uveitis in 73 cases of child and adolescent cataract were retrospectively analyzed.Age-related cataract,diabetic cataract,children cataract were divided into group A,group B and group C.We compared the rates of delayed uveitis of group A with group B,and group A with group C to see if it has statistically significant difference,using statistical methods x2inspection comparison.Results The rates of delayed uveitis between age-related cataract and diabetic cataract was statistically significantly different (P < 0.0l ),the rates of delayed uveitis between age-related cataract and children cataract was statistically significantly different ( P < 0.01 ).Conclusion Diabetes and younger are considered as the factors of delayed uveitis.The prognosis depends on the early treatment.%目的 探讨白内障人工晶体植入术后出现的迟发性葡萄膜炎的发病机制及其相关影响因素.方法 系统性同顾545例(596眼)年龄相关性白内障摘出术后迟发性葡萄膜反应27眼;糖尿病性的白内障92例(92眼),术后迟发性葡萄膜反应15眼;青少年儿童白内障73例(73眼),术后迟发性葡萄膜反应11眼.将年龄相关性白内障、糖尿病性白内障、青少年儿童白内障依次分作A组、B组和C组,比较A组与B组、A组与C组间术后迟发性葡萄膜炎的发病情况差异.结果 年龄相关性白内障术后迟发性葡萄膜反应发生率为4.53%与糖尿病性白内障术后发生率(16.38%)之间差异有统计学意义(P<0.01);与青少年儿童白内障术后发生率(15.07%)之间差异也有统计学意义(P<0.01).结论 青少年儿童白内障、糖尿病性白内障患者人工晶状体植

  20. Physics of electrostatic lens

    Science.gov (United States)

    1981-09-01

    The purpose of this program was to study the physics of the ion-energy boosting electrostatic lens for collective ion acceleration in the Luce diode. Extensive work was done in preparation for experiments on the PI Pulserad 1150. Analytic work was done on the orbit of protons in a mass spectrometer and a copper stack for nuclear activation analysis of proton energy spectrum has been designed. Unfortunately, a parallel program which would provide the Luce diode for the collective ion acceleration experiment never materialized. As a result no experiments were actually performed on the Pulserad 1150.

  1. Media Language, Clear or Obscure

    DEFF Research Database (Denmark)

    Jakobsen, Bjarne le Fevre; Ejstrup, Michael

    2015-01-01

    Abstract— Be clear, not obscure. One of the four maxims for optimal communication is that it is essential to develop proficiency in being concise and clear. The question is whether this is really a good idea in all contexts. There is some evidence to the contrary. Undoubtedly, we have many contex...

  2. Media Language, Clear or Obscure

    DEFF Research Database (Denmark)

    Ejstrup, Michael; le Fevre Jakobsen, Bjarne

    2015-01-01

    Be clear, not obscure. One of the four maxims for optimal communication is that it is essential to develop proficiency in being concise and clear. The question is whether this is really a good idea in all contexts. There is some evidence to the contrary. Undoubtedly, we have many contexts where i...

  3. Lens regeneration in juvenile and adult rabbits measured by image analysis.

    Science.gov (United States)

    Gwon, A E; Jones, R L; Gruber, L J; Mantras, C

    1992-06-01

    Secondary cataract growth commonly occurs after extracapsular cataract extraction. The proliferation of this regrowth occurs at rates related to many factors. In this study, the authors analyzed the amount of lens regeneration after endocapsular lens extraction that leaves the anterior and posterior capsules relatively intact. The analysis was performed in New Zealand albino rabbits with the aid of image analysis measurements in young and adult animals. The effect of low vacuum suction of the anterior capsule on the growth was determined. Lens regeneration was used as a measure of the growth potential of the leftover epithelial cells in the capsule bag. The results showed that lens regeneration was significantly faster in younger rabbits. However, low vacuum suction had no effect on the growth rate. Potential therapeutic agents for preventing secondary cataracts may be better analyzed with image analysis processing of lens regeneration, a precise and rapid measurement technique.

  4. Delayed Hyphema after Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    A56-year-old man with senile cataract in the left eye underwent extracapsularcataract extraction(ECCE)and posteriorchamber intraocular lens(IOL)implanta-tion on December 19,1988.A 13D J-loopplannar lens was inserted in the ciliary sul-cus.The operation was successful with mildpostoperative response.His corrected visionwas 20/20. He had a follow-up examination onMarch 20,1989.No complication was notedand his vision retained 20/20.In theevening of the same day,the patient sud-denly felt discomfortable and...

  5. Flat acoustic lens by acoustic grating with curled slits

    KAUST Repository

    Peng, Pai

    2014-10-01

    We design a flat sub-wavelength lens that can focus acoustic wave. We analytically study the transmission through an acoustic grating with curled slits, which can serve as a material with tunable impedance and refractive index for acoustic waves. The effective parameters rely on the geometry of the slits and are independent of frequency. A flat acoustic focusing lens by such acoustic grating with gradient effective refractive index is designed. The focusing effect is clearly observed in simulations and well predicted by the theory. We demonstrate that despite the large impedance mismatch between the acoustic lens and the matrix, the intensity at the focal point is still high due to Fabry-Perot resonance.

  6. A planar lens based on the electrowetting of two immiscible liquids

    International Nuclear Information System (INIS)

    This paper reports the development and characterization of a planar liquid lens based on electrowetting. The working concept of electrowetting two immiscible liquids is demonstrated with measurement and characterization of contact angles with regard to externally applied electric voltages. Consequently, a planar liquid lens is designed and implemented based on this competitive electrowetting. A droplet of silicone oil confined in an aqueous solution (1% KCl) works as a liquid lens. Electrowetting then controls the shape of the confined silicone oil and the focal length of the liquid lens varies depending upon an applied dc voltage. A unique feature of this lens design is the double-ring planar electrodes beneath the hydrophobic substrate. While an outer ring electrode provides an initial boundary for the silicone oil droplet, an inner ring works as the actuation electrode for the lens. Further, the planar electrodes, instead of vertical or out-of-plane wall electrodes, facilitate the integration of liquid lenses into microfluidic systems. With the voltage applied in the range of 50–250 V, the confined silicone oil droplet changed its shape and the optical magnification of a 3 mm-diameter liquid lens was clearly demonstrated. Moreover, focal lengths of liquid lenses with diameters of 2 mm, 3 mm and 4 mm were characterized, respectively. The obtained results suggest that a larger lens diameter yields a longer focal length and a wider range of focal length change in response to voltage. The demonstrated liquid lens has a simple structure and is easy to fabricate

  7. Photothermal Lens Aberration Effects in Two Laser Thermal Lens Spectrometry

    OpenAIRE

    Bialkowski, Stephen E.

    1985-01-01

    A comparison of theories describing two laser photothermal lens signals is given. The aberrant nature of this lens is accounted for in a theory which treats the propagation of a monitor laser in terms of a phase shift in this laser beam wave front. The difference between theories are discussed in terms of the predicted signal strengths and temporal behavior. The aberrant theory results in smaller theoretical signal strengths and different functional relationships between signal and analyte le...

  8. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    I.J.E. van der Meulen; L.A. Engelbrecht; J.M.J. van Vliet; R. Lapid-Gortzak; C.P. Nieuwendaal; M.P. Mourits; R.O. Schlingemann; T.J.T.P. van den Berg

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens remov

  9. Experimental study on cyclosporine A drug delivery system in prevention of posterior capsule opacification after intraocular lens implantation in rabbits

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Objective To study the effect of cyclosporine A drug delivery system (CsA-DDS) on the prevention of posterior capsule opacification (PCO) after experimental intraocular lens implantation in rabbit eyes. Methods Twenty healthy New Zealand white rabbits, whose left eyes and right eyes were used respectively as experiment eyes and controls, were subjected to extracapsular lens extraction and artificial lens implantation. During the operation, CsA-DDS with poly (lactideco-glycolide) as carriers or empty DDS was...

  10. Lens siderosis resulting from a small intralenticular metallic foreign body

    Directory of Open Access Journals (Sweden)

    Shah, Mehul A.

    2015-11-01

    Full Text Available We report a rare case of lens siderosis with an undetectable intraocular foreign body by imaging. An 8-year-old boy presented with diminution of vision in the left eye since 3 months. His parents gave a preceding uncertain history of a foreign body injury to his left eye 3 months ago while playing. Presenting visual acuity in the left eye was perception of hand movements. Slit-lamp examination revealed a total white cataract with brownish-pigmented spots on the anterior capsule of the lens, but no intraocular foreign body was found. There was also no evidence of an intraocular foreign body on ultrasonography. Patient underwent cataract extraction with intraocular lens implantation. During the operation, a small (2×1×1 mm in size intralenticular foreign body of metal material was found and removed carefully with a magnet. The patient regained 20/30 vision after surgery.

  11. Investigation into photostability of soybean oils by thermal lens spectroscopy.

    Science.gov (United States)

    Savi, E L; Malacarne, L C; Baesso, M L; Pintro, P T M; Croge, C; Shen, J; Astrath, N G C

    2015-06-15

    Assessment of photochemical stability is essential for evaluating quality and the shelf life of vegetable oils, which are very important aspects of marketing and human health. Most of conventional methods used to investigate oxidative stability requires long time experimental procedures with high consumption of chemical inputs for the preparation or extraction of sample compounds. In this work we propose a time-resolved thermal lens method to analyze photostability of edible oils by quantitative measurement of photoreaction cross-section. An all-numerical routine is employed to solve a complex theoretical problem involving photochemical reaction, thermal lens effect, and mass diffusion during local laser excitation. The photostability of pure oil and oils with natural and synthetic antioxidants is investigated. The thermal lens results are compared with those obtained by conventional methods, and a complete set of physical properties of the samples is presented.

  12. Investigation into photostability of soybean oils by thermal lens spectroscopy

    Science.gov (United States)

    Savi, E. L.; Malacarne, L. C.; Baesso, M. L.; Pintro, P. T. M.; Croge, C.; Shen, J.; Astrath, N. G. C.

    2015-06-01

    Assessment of photochemical stability is essential for evaluating quality and the shelf life of vegetable oils, which are very important aspects of marketing and human health. Most of conventional methods used to investigate oxidative stability requires long time experimental procedures with high consumption of chemical inputs for the preparation or extraction of sample compounds. In this work we propose a time-resolved thermal lens method to analyze photostability of edible oils by quantitative measurement of photoreaction cross-section. An all-numerical routine is employed to solve a complex theoretical problem involving photochemical reaction, thermal lens effect, and mass diffusion during local laser excitation. The photostability of pure oil and oils with natural and synthetic antioxidants is investigated. The thermal lens results are compared with those obtained by conventional methods, and a complete set of physical properties of the samples is presented.

  13. Contact lens management of keratoconus.

    Science.gov (United States)

    Downie, Laura E; Lindsay, Richard G

    2015-07-01

    Contact lenses are the primary form of visual correction for patients with keratoconus. Contemporary advances in contact lens designs and materials have significantly expanded the available fitting options for patients with corneal ectasia. Furthermore, imaging technology, such as corneal topography and anterior segment optical coherence tomography, can be applied to both gain insight into corneal microstructural changes and to guide contact lens fitting. This paper provides a comprehensive review of the range of contact lens modalities, including soft lenses, hybrid designs, rigid lenses, piggyback configurations, corneo-scleral, mini-scleral and scleral lenses that are currently available for the optical management of keratoconus. The review also discusses the importance of monitoring for disease progression in patients with keratoconus, in particular children, who tend to undergo more rapid progressive changes, so as to facilitate appropriate modification to contact lens fitting and/or potential referral for corneal collagen cross-linking treatment, as appropriate. PMID:26104589

  14. Intraocular lens fixation with dacron.

    Science.gov (United States)

    Peyman, G A; Koziol, J E

    1978-10-01

    To overcome the problem of postoperative lens dislocation, we evaluated a new means of lens fixation. Our experimental studies in rabbits and primates demonstrated that Dacron polyethylene terephtalate induced a cellular reaction from either the anterior or posterior iris surface when placed in contact with the iris, thereby establishing a bond between the Dacron fibers and the iris. Dacron mesh can be attached to the distal portion of either the anterior or posterior loops of a Binkhorst iris clip (4-loop) lens. In the rabbit eye, lens fixation occurred within five days; in the primate eye, 30 days. When combined with silk, Dacron produced tissue ingrowth in the primate eye within 14 days. No unwanted reaction occurred in any animal with the Dacron and silk combination. Being biodegradable, the silk induced faster cellular ingrowth than the Dacron. However, Dacron, which is not biodegradable, provided a permanent means of fixation. PMID:155053

  15. Study on effects of cataract extraction combined with intraocular lens implantation for treating angle-closure glaucoma%白内障摘除联合人工晶体植入治疗闭角型青光眼的疗效探讨

    Institute of Scientific and Technical Information of China (English)

    杨宇红; 李立刚; 高作书; 傅刚; 郭小博

    2015-01-01

    目的:探讨白内障摘除联合人工晶体植入的手术方式治疗闭角型青光眼合并白内障的疗效。方法将收治的白内障合并闭角型青光眼的患者108例(126眼)随机分成对照组和观察组,对照组选择白内障摘除联合人工晶体植入术联合小梁切除术进行治疗,观察组选择白内障摘除联合人工晶体植入术进行治疗,对两组的治疗效果数据进行分析。结果治疗后,观察组患者视力的提高明显高于对照组,差异有统计学意义(P<0.05)。观察组的眼压由(25.29±5.33)mm Hg降至(14.23±4.11)mm Hg ,对照组的眼压由(25.74±5.12)mm Hg降至(14.36±4.02)mmHg ,两组眼压均有明显降低。观察组术后并发症的发生率(12.5%)明显低于对照组(37.1%)。结论白内障摘除联合人工晶体植入治疗闭角型青光眼合并白内障,能够有效提高患者的治疗效果及生活质量,可作为临床较为理想的治疗白内障合并青光眼的方案之一。%Objective To investigate the effect of cataract extraction combined with intraocular lens implanta‐tion for treating cataract complicating angle‐closure glaucoma .Methods 108 cases (126 eyes) of cataract complica‐ting angle‐closure glaucoma were allocated into the control group and the observation group .The control group was treated with cataract extraction combined with intraocular lens implantation and trabeculectomy ,while the observa‐tion group was treated with cataract extraction combined with intraocular lens implantation .The treatment effects were analyzed and compared between the two groups .Results The vision improvement after treatment in the obser‐vation group was obviously higher than that in the control group ,and the difference was statistically significant .The intraocular pressuregop(IOP) in the obserration group was decreased from (25 .29 ± 5 .33)mm Hg to (14 .23 ± 4 .11) mm Hg .IOP

  16. Crystallins of the octopus lens. Recruitment from detoxification enzymes.

    Science.gov (United States)

    Tomarev, S I; Zinovieva, R D; Piatigorsky, J

    1991-12-15

    The eye lens crystallins of the octopus Octopus dofleini were identified by sequencing abundant proteins and cDNAs. As in squid, the octopus crystallins have subunit molecular masses of 25-30 kDa, are related to mammalian glutathione S-transferases (GST), and are encoded in at least six genes. The coding regions and deduced amino acid sequences of four octopus lens cDNAs are 75-80% identical, while their non-coding regions are entirely different. Deduced amino acid sequences show 52-57% similarity with squid GST-like crystallins, but only 20-25% similarity with mammalian GST. These data suggest that the octopus and squid lens GST-like crystallin gene families expanded after divergence of these species. Northern blot hybridization indicated that the four octopus GST-like crystallin genes examined are lens-specific. Lens extracts showed about 40 times less GST activity using 1-chloro-2,4-dinitrobenzene as substrate than liver extracts of the octopus, indicating that the major GST-like crystallins are specialized for a lens structural role. A prominent 59-kDa crystallin polypeptide, previously observed in octopus but not squid and called omega-crystallin (Chiou, S.-H. (1988) FEBS Lett. 241, 261-264), has been identified as an aldehyde dehydrogenase. Since cytoplasmic aldehyde dehydrogenase is a major protein in elephant shrew lenses (eta-crystallin; Wistow, G., and Kim, H. (1991) J. Mol. Evol. 32, 262-269) the octopus aldehyde dehydrogenase crystallin provides the first example of a similar enzyme-crystallin in vertebrates and invertebrates. The use of detoxification stress proteins (GST and aldehyde dehydrogenase) as cephalopod crystallins indicates a common strategy for recruitment of enzyme-crystallins during the convergent evolution of vertebrate and invertebrate lenses. For historical reasons we propose that the octopus GST-like crystallins, like those of the squid, are called S-crystallins. PMID:1721068

  17. Inverse Design of Electron Lens

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The inverae design of electron lens is reelized by two different methods in this paper. One isdamped leastsquare method and the other is the artificial neural network method. Their merits and defects are discussed accordingto our calculation results in the psper. In the condition of selecting the learning samples properly, the artificial neuralnetwork has obvious advantages in the inverse design of electron lens. It is an effective method to solve the inversedesign problem in the electron optic system.

  18. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; P Agarwal

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  19. Phakic Intraocular lens- a review

    OpenAIRE

    Cruz, Francisco Miguel

    2015-01-01

    Introduction: Intraocular refractive procedures with the implantation of a Phakic Intraocular lens have become a safe efficient and predictable alternative for treating high ametropias when the use of corneal photoablative procedures is not possible. The implantation of Phakic intraocular lens preservs the accomodative function,is a reversable refractive procedure, with minimal induction of higher order aberrations compaed with corneal photoablative procedures. Methods: An analytical review o...

  20. Nanoceria have no genotoxic effect on human lens epithelial cells

    Science.gov (United States)

    Pierscionek, Barbara K.; Li, Yuebin; Yasseen, Akeel A.; Colhoun, Liza M.; Schachar, Ronald A.; Chen, Wei

    2010-01-01

    There are no treatments for reversing or halting cataract, a disease of the structural proteins in the eye lens, that has associations with other age-related degenerative conditions such as Alzheimer's disease. The incidence of cataract and associated conditions is increasing as the average age of the population rises. Protein folding diseases are difficult to assess in vivo as proteins and their age-related changes are assessed after extraction. Nanotechnology can be used to investigate protein changes in the intact lens as well as for a potential means of drug delivery. Nanoparticles, such as cerium oxide (CeO2) which have antioxidant properties, may even be used as a means of treating cataract directly. Prior to use in treatments, nanoparticle genotoxicity must be tested to assess the extent of any DNA or chromosomal damage. Sister chromatid exchanges were measured and DNA damage investigated using the alkaline COMET assay on cultured human lens epithelial cells, exposed to 5 and 10 µg ml-1 of CeO2 nanoparticles (nanoceria). Nanoceria at these dosages did not cause any DNA damage or significant increases in the number of sister chromatid exchanges. The absence of genotoxic effects on lens cells suggests that nanoceria, in the doses and exposures tested in this study, are not deleterious to the eye lens and have the potential for use in studying structural alterations, in developing non-surgical cataract treatments and in investigating other protein folding diseases.

  1. Nanoceria have no genotoxic effect on human lens epithelial cells

    International Nuclear Information System (INIS)

    There are no treatments for reversing or halting cataract, a disease of the structural proteins in the eye lens, that has associations with other age-related degenerative conditions such as Alzheimer's disease. The incidence of cataract and associated conditions is increasing as the average age of the population rises. Protein folding diseases are difficult to assess in vivo as proteins and their age-related changes are assessed after extraction. Nanotechnology can be used to investigate protein changes in the intact lens as well as for a potential means of drug delivery. Nanoparticles, such as cerium oxide (CeO2) which have antioxidant properties, may even be used as a means of treating cataract directly. Prior to use in treatments, nanoparticle genotoxicity must be tested to assess the extent of any DNA or chromosomal damage. Sister chromatid exchanges were measured and DNA damage investigated using the alkaline COMET assay on cultured human lens epithelial cells, exposed to 5 and 10 μg ml-1 of CeO2 nanoparticles (nanoceria). Nanoceria at these dosages did not cause any DNA damage or significant increases in the number of sister chromatid exchanges. The absence of genotoxic effects on lens cells suggests that nanoceria, in the doses and exposures tested in this study, are not deleterious to the eye lens and have the potential for use in studying structural alterations, in developing non-surgical cataract treatments and in investigating other protein folding diseases.

  2. Nanoceria have no genotoxic effect on human lens epithelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Pierscionek, Barbara K; Yasseen, Akeel A [School of Biomedical Sciences, University of Ulster, Coleraine, BT52 1SA (United Kingdom); Li, Yuebin; Schachar, Ronald A; Chen, Wei [Department of Physics, University of Texas at Arlington, Arlington, TX 76019 (United States); Colhoun, Liza M, E-mail: b.pierscionek@ulster.ac.uk, E-mail: weichen@uta.edu [Centre for Vision and Vascular Sciences, School of Medicine, Dentistry and Biomedical Sciences, Queen' s University Belfast, Grosvenor Road, Belfast, BT12 6BA (United Kingdom)

    2010-01-22

    There are no treatments for reversing or halting cataract, a disease of the structural proteins in the eye lens, that has associations with other age-related degenerative conditions such as Alzheimer's disease. The incidence of cataract and associated conditions is increasing as the average age of the population rises. Protein folding diseases are difficult to assess in vivo as proteins and their age-related changes are assessed after extraction. Nanotechnology can be used to investigate protein changes in the intact lens as well as for a potential means of drug delivery. Nanoparticles, such as cerium oxide (CeO{sub 2}) which have antioxidant properties, may even be used as a means of treating cataract directly. Prior to use in treatments, nanoparticle genotoxicity must be tested to assess the extent of any DNA or chromosomal damage. Sister chromatid exchanges were measured and DNA damage investigated using the alkaline COMET assay on cultured human lens epithelial cells, exposed to 5 and 10 {mu}g ml{sup -1} of CeO{sub 2} nanoparticles (nanoceria). Nanoceria at these dosages did not cause any DNA damage or significant increases in the number of sister chromatid exchanges. The absence of genotoxic effects on lens cells suggests that nanoceria, in the doses and exposures tested in this study, are not deleterious to the eye lens and have the potential for use in studying structural alterations, in developing non-surgical cataract treatments and in investigating other protein folding diseases.

  3. Plain Language Clear and Simple.

    Science.gov (United States)

    National Literacy Secretariat, Ottawa (Ontario).

    Written for Canadian public servants and written with their help, this handbook presents principles and tips to make official writing clear, concise, and well organized. The handbook defines "plain language" writing as a technique of organizing information in ways that make sense to the reader--using familiar, straightforward words. The handbook…

  4. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  5. Gabor lens theory

    International Nuclear Information System (INIS)

    The principle of using the space charge of an electron cloud to focus ion beams was first proposed by Gabor. Electrons are to be confined radially by means of an axial magnetic field B/sub z/ and axially by means of externally applied electric fields E/sub z/. An ion beam of charge density n/sub i/ much less than n/sub e/, the electron charge density can then be focused by the radial electric field set up by the electron cloud. The case considered here is that of a hollow cylindrical conductor charged to a potential +V with grounded rings on either side to set up the axial E/sub z/ field. A solenoid wound around the central conductor supplies the B/sub z/ field. Theoretical calculations are carried out for n/sub e/ maximum as a function of B/sub z/ due to radial confinement and V due to axial confinement and the focal length of the Gabor Lens is calculated

  6. The art of thinking clearly

    CERN Document Server

    Dobelli, Rolf

    2013-01-01

    The Art of Thinking Clearly by world-class thinker and entrepreneur Rolf Dobelli is an eye-opening look at human psychology and reasoning — essential reading for anyone who wants to avoid “cognitive errors” and make better choices in all aspects of their lives. Have you ever: Invested time in something that, with hindsight, just wasn’t worth it? Or continued doing something you knew was bad for you? These are examples of cognitive biases, simple errors we all make in our day-to-day thinking. But by knowing what they are and how to spot them, we can avoid them and make better decisions. Simple, clear, and always surprising, this indispensable book will change the way you think and transform your decision-making—work, at home, every day. It reveals, in 99 short chapters, the most common errors of judgment, and how to avoid them.

  7. Central Clearing of OTC Derivatives

    DEFF Research Database (Denmark)

    Cont, Rama; Kokholm, Thomas

    2014-01-01

    We study the impact of central clearing of over-the-counter (OTC) transactions on counterparty exposures in a market with OTC transactions across several asset classes with heterogeneous characteristics. The impact of introducing a central counterparty (CCP) on expected interdealer exposure...... is determined by the tradeoff between multilateral netting across dealers on one hand and bilateral netting across asset classes on the other hand. We find this tradeoff to be sensitive to assumptions on heterogeneity of asset classes in terms of `riskyness' of the asset class as well as correlation...... of exposures across asset classes. In particular, while an analysis assuming independent, homogeneous exposures suggests that central clearing is efficient only if one has an unrealistically high number of participants, the opposite conclusion is reached if differences in riskyness and correlation across asset...

  8. Writing clear animal activity proposals.

    Science.gov (United States)

    Pinson, David M

    2011-06-01

    Although IACUC-related topics are frequently discussed in the literature, there is little published information about how to write animal activity proposals. In this article, the author discusses key considerations in the writing and review of animal activity proposals. The author then describes a framework for developing and writing clear animal activity proposals that highlight animal welfare concerns. Though these recommendations are aimed at individuals writing and reviewing research proposals, the framework can be modified for other types of animal activity proposals.

  9. 77 FR 21277 - Customer Clearing Documentation, Timing of Acceptance for Clearing, and Clearing Member Risk...

    Science.gov (United States)

    2012-04-09

    ...\\ Clearing Member Risk Management, 76 FR 45724 (Aug. 1, 2011). \\7\\ Adaption of Regulations to Incorporate... ``risk management.'' See, e.g., proposed Sec. 39.13 relating to risk management for DCOs, 76 FR at 3720... an important risk mitigant. This time lag potentially presents credit risk to the swap...

  10. A Situated Cognition Perspective on Literacy Discourses: Seeing More Clearly through a New Lens.

    Science.gov (United States)

    Taylor, Maurice C.; Blunt, Adrian

    2001-01-01

    Using a situated cognition framework, 24 vignettes of literacy practices were examined in 4 Canadian settings: community-based, workplace, family, and school-based literacy. Literacy researchers appear constrained by behaviorist, normative perspectives despite the shift toward humanist perspectives. (Contains 51 references.) (SK)

  11. Pharmacognostic evaluation of Lens culinaris Medikus seeds

    Institute of Scientific and Technical Information of China (English)

    Kripi Vohra; Vivek Kumar Gupta

    2012-01-01

    Objective: To present a detailed pharmacognostic study of the Lens culinaris Medikus (Fabaceae) seeds, a food grain used as Dhal in India. Methods: The macroscopy, microscopy, fluorescence analysis of powdered drug, physicochemical analysis, preliminary testing and other WHO recommended methods for standardization were investigated. Results: Seeds are greyish brown in colour. Treatment of powdered drug with various chemical reagents showed the presence of proteins, cellulose, lignins and fixed oils. Microscopy of seeds revealed the presence of starch grains in seed. The colour of seed coat changed from brown to greenish grey in day light and brown to black at 254nm when treated with acetic acid. Total ash value of the seeds was found to be 1.86% w/w whereas foreign organic matter was found to be nil. Qualitative phytochemical analysis revealed the presence of tannins and flavonoids in acetone extract. Conclusions: The present study on pharmacognostic profile of Lens culinaris Medikus seeds provides an important tool in identification and authentication of this plant to researchers in future.

  12. Adding a lens Improves spinning speed characterization.

    Science.gov (United States)

    Mihaliuk, Eugene; Gullion, Terry

    2015-11-01

    Highly stable sample rotation is important in many solid-state NMR experiments. Whether the necessary stability is achieved is not always clear. Typically only an average frequency over some time interval (often relatively long and unknown) is available from the spinning speed controller readout, which is not representative of the short-term variations of instantaneous rotation frequency. The necessity of the relatively slow measurement of spinning speed is a consequence of phase noise in the tachometer, which prevents speed measurement to be both rapid and precise at the same time. We show that adding a lens to the tachometer, without any other changes in the probe, reduces phase noise by nearly an order of magnitude and allows improved measurement of the spinning speed.

  13. Lens Epithelial Cell Proliferation and Cell Density in Human Age-related Cataract

    Institute of Scientific and Technical Information of China (English)

    Xialin Liu; Yizhi Liu; Jianliang Zheng; Qiang Huang; Huling Zheng

    2000-01-01

    Purpose: To discuss the potential effect of the lens epithelial cell proliferation in age-related cataract.Methods: In vitro cell proliferation was assayed by MTT method to evaluate the lens epithelial cell density, index, and proliferation capacity in normal lens and all kinds of age-related cataract. Capsulotomy specimens from all kinds of patients who underwent cataract phacoemulsification extraction surgery were compared with the lens epithelial specimens from non-cataract lenses of Eye Bank eyes.Results: Lens epithelial cell density of central anterior capsule (LECD) in female normal lens was higher than that in male, LECD in nuclear cataract( > NⅢ ) was higher than that in normal lens, but in the mature cortical cataract, LF CD was lower. Mitotic index of three kinds of age-related cataracts in vivo had no statistical difference, neither did cell proliferation capacity of cultivated cells in vitro.Conclusion: The individual difference of lens epithelial cell density and proliferation capacity in vivo may be an important underlying cause for senile cataract in the cellular level, especially for nuclear cataract.

  14. Ion clearing in an ERL

    Science.gov (United States)

    Hoffstaetter, Georg H.; Liepe, Matthias

    2006-02-01

    The rest-gas in the beam-pipe of a particle accelerator is readily ionized by effects like collisions, synchrotron radiation and field emission. Positive ions are attracted to electron beams and create a nonlinear potential in the vicinity of the beam which can lead to beam halo, particle loss, optical errors or transverse and longitudinal instabilities. In an energy recovery linac (ERL) where beam-loss has to be minimal, and where beam positions and emittances have to be very stable in time, these ion effects have to be avoided. Here we investigate three measures of avoiding ion accumulation: (a) A long gap between linac bunch trains that allows ions to drift out of the beam region, a measure regularly applied in linacs; (b) a short ion clearing gap in the beam that leads to a time varying beam potential and produces large excited oscillations of ions around the electron beam, a measure regularly applied in storage rings; (c) Clearing electrodes that create a sufficient voltage to draw ions out of the beam potential, a measure used for DC electron beams and for antiproton beams. For the parameters of the X-ray ERL planned at Cornell University we show that method (a) cannot be applied, method (b) is technically cumbersome, and (c) should be most easily applicable.

  15. 23-gauge pars plana vitrectomy for management of posteriorly dislocated crystalline lens

    OpenAIRE

    Cho M; Chan RVP

    2011-01-01

    Minhee Cho, RV Paul ChanWeill Cornell Medical College, Department of Ophthalmology, New York, NY, USAPurpose: Management of posteriorly dislocated crystalline lens has traditionally been performed with a standard 20-gauge vitrectomy system. This study demonstrates the use of a 23-gauge vitrectomy system for removal of retained lens fragments secondary to spontaneous dislocation or complicated cataract extraction.Methods: A retrospective, noncomparative, interventional consecutive case series ...

  16. Planar immersion lens with metasurfaces

    CERN Document Server

    Ho, John S; Tanabe, Yuji; Yeh, Alexander J; Fan, Shanhui; Poon, Ada S Y

    2015-01-01

    The solid immersion lens is a powerful optical tool that allows light entering material from air or vacuum to focus to a spot much smaller than the free-space wavelength. Conventionally, however, they rely on semispherical topographies and are non-planar and bulky, which limits their integration in many applications. Recently, there has been considerable interest in using planar structures, referred to as metasurfaces, to construct flat optical components for manipulating light in unusual ways. Here, we propose and demonstrate the concept of a planar immersion lens based on metasurfaces. The resulting planar device, when placed near an interface between air and dielectric material, can focus electromagnetic radiation incident from air to a spot in material smaller than the free-space wavelength. As an experimental demonstration, we fabricate an ultrathin and flexible microwave lens and further show that it achieves wireless energy transfer in material mimicking biological tissue.

  17. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  18. Large scale water lens for solar concentration.

    Science.gov (United States)

    Mondol, A S; Vogel, B; Bastian, G

    2015-06-01

    Properties of large scale water lenses for solar concentration were investigated. These lenses were built from readily available materials, normal tap water and hyper-elastic linear low density polyethylene foil. Exposed to sunlight, the focal lengths and light intensities in the focal spot were measured and calculated. Their optical properties were modeled with a raytracing software based on the lens shape. We have achieved a good match of experimental and theoretical data by considering wavelength dependent concentration factor, absorption and focal length. The change in light concentration as a function of water volume was examined via the resulting load on the foil and the corresponding change of shape. The latter was extracted from images and modeled by a finite element simulation.

  19. Quantification of individual proteins in silicone hydrogel contact lens deposits

    OpenAIRE

    Omali, Negar Babaei; Zhao, Zhenjun; Zhu, Hua; Tilia, Daniel; Willcox, Mark D.P.

    2013-01-01

    Purpose The aim of this study was to quantify specific proteins deposited on daily wear silicone hydrogel lenses used in combination with multipurpose disinfecting solutions (MPDSs) by applying multiple-reaction-monitoring mass spectrometry (MRM-MS). Methods Balafilcon A or senofilcon A contact lenses used with different MPDSs on a daily wear schedule were collected. Each worn lens was extracted and then digested with trypsin. MRM-MS was applied to quantify the amounts of lysozyme, lactoferri...

  20. Liquid crystal Fresnel lens display

    Science.gov (United States)

    Wang, Xiao-Qian; Abhishek Kumar, Srivastava; Alwin Tam, Ming-Wai; Zheng, Zhi-Gang; Shen, Dong; Vladimir, Chigrinov G.; Kwok, Hoi-Sing

    2016-09-01

    A novel see-through display with a liquid crystal lens array was proposed. A liquid crystal Fresnel lens display (LCFLD) with a holographic screen was demonstrated. The proposed display system has high efficiency, simple fabrication, and low manufacturing cost due to the absence of a polarizer and color filter. Project supported by Partner State Key Laboratory on Advanced Displays and Optoelectronics Technologies HKUST, China, the National Natural Science Foundation of China (Grant Nos. 61435008 and 61575063), and the Fundamental Research Funds for the Central Universities, China (Grant No. WM1514036).

  1. Computer-aided lens assembly.

    Science.gov (United States)

    Tomlinson, Richard; Alcock, Rob; Petzing, Jon; Coupland, Jeremy

    2004-01-20

    We propose a computer-aided method of lens manufacture that allows assembly, adjustment, and test phases to be run concurrently until an acceptable level of optical performance is reached. Misalignment of elements within a compound lens is determined by a comparison of the results of physical ray tracing by use of an array of Gaussian laser beams with numerically obtained geometric ray traces. An estimate of misalignment errors is made, and individual elements are adjusted in an iterative manner until performance criteria are achieved. The method is illustrated for the alignment of an air-spaced doublet. PMID:14765916

  2. SimpLens: Interactive gravitational lensing simulator

    Science.gov (United States)

    Saha, Prasenjit; Williams, Liliya L. R.

    2016-06-01

    SimpLens illustrates some of the theoretical ideas important in gravitational lensing in an interactive way. After setting parameters for elliptical mass distribution and external mass, SimpLens displays the mass profile and source position, the lens potential and image locations, and indicate the image magnifications and contours of virtual light-travel time. A lens profile can be made shallower or steeper with little change in the image positions and with only total magnification affected.

  3. A broadband transformation-optics metasurface lens

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Xiang; Xiang Jiang, Wei; Feng Ma, Hui; Jun Cui, Tie, E-mail: tjcui@seu.edu.cn [State Key Laboratory of Millimeter Waves, School of Information Science and Engineering, Southeast University, Nanjing 210096 (China)

    2014-04-14

    We present a transformational metasurface Luneburg lens based on the quasi-conformal mapping method, which has weakly anisotropic constitutive parameters. We design the metasurface lens using inhomogeneous artificial structures to realize the required surface refractive indexes. The transformational metasurface Luneburg lens is fabricated and the measurement results demonstrate very good performance in controlling the radiated surface waves.

  4. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials...

  5. Diabetes and contact lens wear.

    Science.gov (United States)

    O'Donnell, Clare; Efron, Nathan

    2012-05-01

    The literature suggests that diabetic patients may have altered tear chemistry and tear secretion as well as structural and functional changes to the corneal epithelium, endothelium and nerves. These factors, together with a reported increased incidence of corneal infection, suggest that diabetic patients may be particularly susceptible to developing ocular complications during contact lens wear. Reports of contact lens-induced complications in diabetic patients do exist, although a number of these reports concern patients with advanced diabetic eye disease using lenses on an extended wear basis. Over the past decade or so, there have been published studies documenting the response of the diabetic eye to more modern contact lens modalities. The results of these studies suggest that contact lenses can be a viable mode of refractive correction for diabetic patients. Furthermore, new research suggests that the measurement of tear glucose concentration could, in future, be used to monitor metabolic control non-invasively in diabetic patients. This could be carried out using contact lenses manufactured from hydrogel polymers embedded with glucose-sensing agents or nanoscale digital electronic technology. The purpose of this paper is to review the literature on the anterior ocular manifestations of diabetes, particularly that pertaining to contact lens wear. PMID:22537249

  6. Professoren og Ålen

    DEFF Research Database (Denmark)

    Poulsen, Bo

    2016-01-01

    Biolog og havforsker Johannes Schmidt regnes for at være Danmarks mest betydningsfulde havforsker gennem tiderne. Hans mange forskningsbaserede jordomsejlinger bragte ham til eksotiske egne og til opdagelsen af adskillige nye dyrearter. Dog blev særligt ålen og dens gydepladser et hovedfokus...

  7. Clearing and Labeling Techniques for Large-Scale Biological Tissues.

    Science.gov (United States)

    Seo, Jinyoung; Choe, Minjin; Kim, Sung-Yon

    2016-06-30

    Clearing and labeling techniques for large-scale biological tissues enable simultaneous extraction of molecular and structural information with minimal disassembly of the sample, facilitating the integration of molecular, cellular and systems biology across different scales. Recent years have witnessed an explosive increase in the number of such methods and their applications, reflecting heightened interest in organ-wide clearing and labeling across many fields of biology and medicine. In this review, we provide an overview and comparison of existing clearing and labeling techniques and discuss challenges and opportunities in the investigations of large-scale biological systems. PMID:27239813

  8. Radiation damage of the lens

    International Nuclear Information System (INIS)

    Explained is the cataract as the lens is one of the most sensitive tissues to radiation, for considering the possible ophthalmological radiation disorder by the Fukushima Nuclear Power Plant Accident (2011). Radiation cataract is observed at 1-2 years after acute high dose exposure, but at low dose, it appears as the late effect. In fact, the disease related to exposure is found in as many as 25% of Chernobyl workers at >10 years post its Accident. Pathologic feature of radiation cataract has been thought to be the posterior subcapsular type. However, the cortical type is shown to be also noted by recent findings in the Chernobyl Accident, in the lens 30-45 years after radiotherapy of infants for dermovascular angioma, in astronaut, and in Hiroshima A-bomb survivors. Acute exposure to 0.5-1.5 Gy results in lens opacity and at >5 Gy, cataract with visual dysfunction. Higher cataract prevalence is recently reported seen in the therapeutic cardiac fluoroscopy where the medians of accumulated doses are 6.0 Sv in doctors and 1.5 Sv in nurses and radiologists. Astronauts exposed at >8 mSv have higher prevalence. Animal experiments have shown that the lens sensitivity to radiation depends on the age. Clinical experience of radiotherapy of the angioma above has suggested the higher sensitivity in young generation, which is supported by the fact that, among 114 inhabitants of 60Co-contaminated building, the dose effect is observable in 61 inhabitants of the age <20 y alone. linear threshold theory (LNT) hypothesis cannot be excluded by above evidences and there is conceivably no (or extremely low) threshold for cataract. The younger the age of exposure, the higher the risk of cataract, and thereby the lens in young generation should be carefully followed-up in Fukushima. (T.T.)

  9. MI Gap Clearing Kicker Magnet Design Review

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Chris; /Fermilab

    2008-10-01

    The kicker system requirements were originally conceived for the NOvA project. NOvA is a neutrino experiment located in Minnesota. To achieve the desired neutrino flux several upgrades are required to the accelerator complex. The Recycler will be used as a proton pre-injector for the Main Injector (MI). As the Recycler is the same size as the MI, it is possible to do a single turn fill ({approx}11 {micro}sec), minimizing the proton injection time in the MI cycle and maximizing the protons on target. The Recycler can then be filled with beam while the MI is ramping to extract beam to the target. To do this requires two new transfer lines. The existing Recycler injection line was designed for 10{pi} pbar beams, not the 20{pi} proton beams we anticipate from the Booster. The existing Recycler extraction line allows for proton injection through the MI, while we want direct injection from the Booster. These two lines will be decommissioned. The new injection line from the MI8 line into the Recycler will start at 848 and end with injection kickers at RR104. The new extraction line in the RR30 straight section will start with a new extraction kicker at RR232 and end with new MI injection kickers at MI308. Finally, to reduce beam loss activation in the enclosure, a new gap clearing kicker will be used to extract uncaptured beam created during the slip stack injection process down the existing dump line. It was suggested that the MI could benefit from this type of system immediately. This led to the early installation of the gap clearing system in the MI, followed by moving the system to Recycler during NOvA. The specifications also changed during this process. Initially the rise and fall time requirements were 38 ns and the field stability was {+-}1%. The 38 ns is based on having a gap of 2 RF buckets between injections. (There are 84 RF buckets that can be filled from the Booster for each injection, but 82 would be filled with beam. MI and Recycler contain 588 RF buckets

  10. Lactate Dehydrogenase Isoenzyme of Lens in Fetus

    Institute of Scientific and Technical Information of China (English)

    Kexi Ding; Yasong Zhang

    2002-01-01

    Purpose: The LDH isoenzyme patterns were evaluated in lens of fetus to study the metabolism in human lenses.Methods: LDH isoenzyme electrophoresis was performed in 15 lenses of human fetus aged from 4~6 months.Results: There are 5 bands of LDH in fetus lens. LDH4 lever is the highest, and LDH1 is the lowest, especially in the cortex of lens. LDH1 is higher in lens of 4 months of age than in that of 5 and 6 months of age.Conclusions: LDH isoenzyme in lens of fetus shows mainly anaerobic metabolism in development, but there is also aerobic metabolism, especially in younger fetus.

  11. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  12. Modified Scleral Flap Incision to Reduce Corneal Astigmatisn after Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    YizhiLiu; ShaozhenLi

    1995-01-01

    Purpose:To investigate a simple method during extracapsular cataract extraction with posteior chamber intraocular lens implantation in order to reduce surgically induced corneal astig-matism.Methods:A modified scleral flap incision was used in the extracapsular cataract extraction with intraocular lens implantation and the postoperative changes in conreal astigmatism was observed.Results:The peak value of postoperative corneal astigmatism was3.60D,and the corneal astigmatism regression was 2.11D,surgically induced astigmatism was less significant in modified scleral flap incision group than that in convention-al limbal incison group(P<0.05).Conclusions:The modified scleral flap inciston is an ideal incision for cataract ex-traction with intraocular lens implantation when phacoemulsifier is not avaliable.Eye Science1995;11:136-139.

  13. Contact lens surface by electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jung Hyuck [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin [Dongshin Univ., Naju (Korea, Republic of)

    2011-07-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility.

  14. Conjunctival impression cytology in contact lens wearers.

    Directory of Open Access Journals (Sweden)

    Simon Priya

    2002-01-01

    Full Text Available PURPOSE: To evaluate the cytological changes in conjunctiva following regular contact lens wear and to determine the correlation, if any, between severity of cytological alteration and symptoms related to contact lens wear. METHODS: One hundred eyes (50 normal asymptomatic subjects who served as a control group were studied by conjunctival impression cytology (CIC. These subjects were fitted with rigid gas permeable (RGP or soft contact lenses and were followed up at the end of 3 and 6 months. At each follow-up visit the CIC was repeated. A filter paper with the impression specimen was stained with periodic acid schiff (PAS and haematoxylin stain to study goblet cell loss. Papanicolaou stain was done to study squamous metaplasia. The cytological changes were graded using the system described by Natadisastra et al. RESULTS: Severity of cytological changes increased with the duration of contact lens wear (P = 0.00001. At the end of 6 months, 60% of symptomatic eyes wearing soft contact lens and RGP lens showed abnormal CIC changes. None of the asymptomatic RGP contact lens wearing eyes showed abnormal CIC changes whereas 33.4% of the asymptomatic soft contact lens wearing eyes showed abnormal CIC changes (P = 0.033. Epithelial changes occurred within 3-6 months of contact lens fitting. CONCLUSION: Severity of cytological changes increased with duration of lens wear (P = 0.00001. Prevalence and severity of cytological alteration is more in symptomatic contact lens wearers. Soft contact lens wearers although asymptomatic showed severe CIC changes.

  15. A broadband terahertz ultrathin multi-focus lens

    Science.gov (United States)

    He, Jingwen; Ye, Jiasheng; Wang, Xinke; Kan, Qiang; Zhang, Yan

    2016-06-01

    Ultrathin transmission metasurface devices are designed on the basis of the Yang-Gu amplitude-phase retrieval algorithm for focusing the terahertz (THz) radiation into four or nine spots with focal spacing of 2 or 3 mm at a frequency of 0.8 THz. The focal properties are experimentally investigated in detail, and the results agree well with the theoretical expectations. The designed THz multi-focus lens (TMFL) demonstrates a good focusing function over a broad frequency range from 0.3 to 1.1 THz. As a transmission-type device based on metasurface, the diffraction efficiency of the TMFL can be as high as 33.92% at the designed frequency. The imaging function of the TMFL is also demonstrated experimentally and clear images are obtained. The proposed method produces an ultrathin, low-cost, and broadband multi-focus lens for THz-band application

  16. Improvement and application effect of water vapor moving signal extraction algorithm in “clear sky region” from FY-2 E infrared channel%FY-2 E红外通道“晴空区”水汽信息提取算法的改进与应用效果

    Institute of Scientific and Technical Information of China (English)

    赵航; 王振会; 杨璐; 詹奕哲; 汤敏

    2015-01-01

    The quadratic difference method, as an improved water vapor signal extraction algorithm, is employed in“clear sky region” from FY -2E infrared channel. By means of both split window and temporal difference calculation from infrared cloud mask images, the method can weaken the surface temperature interference and help trace the weak signal of water vapor in “clear sky region”, regardless of the order of the two calculations. Application examples show that this method can trace the weak signal of water vapor in “clear sky region” more effectively and make up for the lacking wind field data in clear sky with high water vapor content values as compared with the obvious limitation of deriving cloud motion wind by the traditional method. A comparison between the wind fields using this technique and that obtained from the NCEP reanalysis data shows a good relative accuracy.%提出了一种改进的FY-2E红外通道“晴空区”水汽信息提取算法———二次差分法,即在对红外分裂窗云掩图进行分裂窗差分的基础上再进行时间差分处理,或者先进行时间差分后再进行分裂窗差分处理。该方法能减弱晴空区地表温度变化对水汽信息提取的干扰,从而有助于获得水汽团的纹理及其移动信息。实验结果表明,应用该方法可以更加有效地追踪红外通道“晴空区”水汽微弱示踪信号的移动,获得传统云导风方法所无法得到的晴空水汽含量高值区风场信息,且晴空风矢与NCEP( national centers for environmental prediction)再分析资料级低空风场有着很好的一致性。

  17. The Experimental Study on Implantation of Intraocular Lens in Different Animals

    Institute of Scientific and Technical Information of China (English)

    WANGGui-qin; PENGXiu-jun; GUHan-qing

    2004-01-01

    To prevent the complications in cataract surgeries, the eyes of rabbits and monkeys were implanted with intraocular lens for 360 days. Methods: The eyes of the rabbits were performed with phacoemulsification and soft intraocular lens implantation. The eyes of the monkeys were performed with extracapsular cataract extraction and hard intraocular lens implantation. Results: The postoperative reactions included corneal edema, anterior chamber exudation, posterior capsule opacification and so on. The complications in the eyes of the rabbits were more than that in the eyes of the monkeys. Conclusion: The different postoperative reactions happened in different animals. In clinical the choice of the operative method and intraocular lens depended on the case in order to acquire the best sight.

  18. Liquid scintillation counting of 3H-thymidine incorporated into rat lens DNA

    International Nuclear Information System (INIS)

    DNA synthesis in the lens has previously been localized by autoradiography following incorporation of 3H-thymidine. For the quantification of DNA synthesis in the lens, pooling of lenses and extraction of the DNA for liquid scintillation counting, has formerly been adapted. In the present investigation a method has been developed for the extraction of the unincorporated tracer from whole lenses after short time incubation in a medium containing 3H-thymidine. The 3H-thymidine incorporated into individual lenses was then detected by liquid scintillation counting after dissolution of the lenses. The sources of the variation in the method are evaluated. (author)

  19. γ-Crystallins of the chicken lens: remnants of an ancient vertebrate gene family in birds.

    Science.gov (United States)

    Chen, Yingwei; Sagar, Vatsala; Len, Hoay-Shuen; Peterson, Katherine; Fan, Jianguo; Mishra, Sanghamitra; McMurtry, John; Wilmarth, Phillip A; David, Larry L; Wistow, Graeme

    2016-04-01

    γ-Crystallins, abundant proteins of vertebrate lenses, were thought to be absent from birds. However, bird genomes contain well-conserved genes for γS- and γN-crystallins. Although expressed sequence tag analysis of chicken eye found no transcripts for these genes, RT-PCR detected spliced transcripts for both genes in chicken lens, with lower levels in cornea and retina/retinal pigment epithelium. The level of mRNA for γS in chicken lens was relatively very low even though the chicken crygs gene promoter had lens-preferred activity similar to that of mouse. Chicken γS was detected by a peptide antibody in lens, but not in other ocular tissues. Low levels of γS and γN proteins were detected in chicken lens by shotgun mass spectroscopy. Water-soluble and water-insoluble lens fractions were analyzed and 1934 proteins (chicken lens proteome 30-fold. Although chicken γS is well conserved in protein sequence, it has one notable difference in leucine 16, replacing a surface glutamine conserved in other γ-crystallins, possibly affecting solubility. However, L16 and engineered Q16 versions were both highly soluble and had indistinguishable circular dichroism, tryptophan fluorescence and heat stability (melting temperature Tm ~ 65 °C) profiles. L16 has been present in birds for over 100 million years and may have been adopted for a specific protein interaction in the bird lens. However, evolution has clearly reduced or eliminated expression of ancestral γ-crystallins in bird lenses. The conservation of genes for γS- and γN-crystallins suggests they may have been preserved for reasons unrelated to the bulk properties of the lens.

  20. Study on Titanium Nitride Film Modified for Intraocular Lens

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective:To study the characteristics of the intraocular lens using ion beam sputtering depositing titanium nitride thin film on the intraocular lens(IOLs).Methods:To deposite titanium nitride thin film on the top of intraocular lens by ion beam sputtering depositing.We analyzed the surface morphology of intraocular lens through SEM and AFM.We detected intraocular lens resolution through the measurement of intraocular lens.Biocompatibility of intraocular lens is preliminary evaluated in this test.Results:T...

  1. Lens Coupled Quantum Cascade Laser

    Science.gov (United States)

    Hu, Qing (Inventor); Lee, Alan Wei Min (Inventor)

    2013-01-01

    Terahertz quantum cascade (QC) devices are disclosed that can operate, e.g., in a range of about 1 THz to about 10 THz. In some embodiments, QC lasers are disclosed in which an optical element (e.g., a lens) is coupled to an output facet of the laser's active region to enhance coupling of the lasing radiation from the active region to an external environment. In other embodiments, terahertz amplifier and tunable terahertz QC lasers are disclosed.

  2. Lens transglutaminase and cataract formation.

    OpenAIRE

    Lorand, L.; Hsu, L K; Siefring, G E; Rafferty, N S

    1981-01-01

    A protein polymer characteristically present in human cataract was shown to contain significant amounts of gamma-glutamyl-epsilon-lysine isopeptides. It is proposed that these crosslinks are produced by the action of transglutaminase (R-glutaminyl-peptide:amine-gamma-glutamyl-yltransferase, EC 2.3.2.13), which is all the more plausible because lens contains the enzyme and endogenous protein substrates for it. The enzyme is similar to that obtained from liver and is Ca2+ dependent. Highest app...

  3. 非洲贫困地区小切口白内障囊外摘出联合人工晶状体植入术的临床分析%Clinical analysis of small incision extracapsular cataract extraction and intraocular lens implantation in poverty-stricken areas in Africa

    Institute of Scientific and Technical Information of China (English)

    唐建明

    2012-01-01

    Objective To investigate the small incision extracapsular cataract extraction and intraocular lens implantation in the clinical effect and feasibility of poverty-stricken areas of Africa.Methods During the foreign aid in Moroccan from march 2009 to march 2011,the age of 45 to 86-year-old Moroccan patients with 538 cases (580 eyes) had undergone small incision extracapsular cataract extraction and intraocular lens implantation.The visual acuity,postoperative complications were observed.Results Visual acuity of1.0 or more were obtained in 25 eyes (4.31%),0.6~1.0in 148 eyes (25.52%),0.3 ~0.5 in 328 eyes (56.55%),0.05 ~0.25 in 74 eyes (12.76%),<0.05 in 5 eyes (0.86%).Literacy rate was 99.14%,removing residual was 86.38%.Intraoperative complications:iris prolapse 23 eyes (3.97%) ; posterior capsular rupture 33 eyes (5.69%),among which 28 eyes were applied posterior chamber intraocular lens implantation at stage Ⅰ,two cases at stage Ⅱ,the other three eases gave up implantation.Postoperative complications:corneal edema,opacity 21 eyes (3.62%),no corneal bullae or corneal decompensation occurred.Anterior chamber inflammatory response 51 eyes (8.79%).Late-onset uveitis 11 eyes,of which 9 related to diabetes.All patients were found no retinal detachment,secondary glaucoma,intraocular lens dislocation or endophthalmitis.Conclusion Small incision extracapsular cataract extraction with IOL implantation in the joint damage,quick recovery,easy to operate,low cost,suitable for the hospital,poor economic conditions,the places and people,it become possible to make the local poor people cataract bright.%目的 探讨在援非工作过程中进行小切口白内障囊外摘出联合人工晶状体植入术的手术效果与可行性.方法 2009年3月至2011年3月作者在援非期间对年龄45 ~ 86岁的摩洛哥患者538人(580眼)进行小切口白内障囊外摘出联合人工晶状体植入术,并对术后视力、术后并发症的

  4. Avaliação da eficácia da facectomia com implante de lente intra-ocular na infância Efficacy of pediatric cataract extraction with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Núbia Cristina de Freitas Maia

    2005-12-01

    . METHODS: A total of 33 eyes in 27 children were studied. Children with either unilateral or bilateral cataracts were submitted to lensectomy surgery via pars plana, with intraocular lens implant, associated with primary posterior capsulectomy and anterior vitrectomy. The intraocular lenses were calculated for emmetropia in the first postoperative month. All children were less than six years old at the time of the surgery and had a 2.9 year average follow-up. They were divided into 3 groups. Group I (10 eyes, children with unilateral cataracts and under three years old at the time of the surgery; group II (11 eyes, children with unilateral cataracts and above three years old; group III (12 eyes, children with bilateral cataracts and above three years old at the time of the surgery. RESULTS: On the last follow-up examination recorded visual acuity was equal to or above 20/40 in 85% of the eyes. A spherical equivalent close to emmetropia in the first postoperative month was obtained in 70% of the children of group III but only in 30% of group I. Regarding postoperative refraction variation, myopic shift was detected in 81.81% of the cases. The younger the children were when undergoing surgery, the greater the refractional alteration. CONCLUSION: Despite the myopic shift that happens with the use of intraocular lenses in the treatment of pediatric aphakia in children under six years old, the visual result is very good and the residual refraction correction is easily performed. A more prolonged postoperative follow-up would be necessary for long-term evaluation of the results.

  5. Commercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system

    Directory of Open Access Journals (Sweden)

    Kamei M

    2012-08-01

    Full Text Available Motohiro Kamei, Nagakazu Matsumura, Hirokazu Sakaguchi, Yusuke Oshima, Yasushi Ikuno, Kohji NishidaDepartment of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, JapanPurpose: We evaluated the usefulness of commercially available materials for protecting the cornea from drying during vitrectomy with a wide-angle viewing system.Methods: Three vitreoretinal surgeons evaluated fundus visibility during vitrectomy on the images of five study materials used on the cornea: balanced saline solution, a viscoelastic agent, a vitrectomy contact lens, a rigid gas permeable (RGP contact lens, and a soft contact lens. Fundus visibility was graded using the following scale: grade 1, unclear; grade 2, slightly unclear; grade 3, clear; and grade 4, very clear.Results: Respective scores for each material used during core vitrectomy and membrane removal were: balanced saline solution, 3.3/3.3; viscoelastic agent, 3.8/3.3; vitrectomy contact lens, 3.3/4.0; RGP contact lens, 4.0/3.9; soft contact lens, 1.1/not applicable.Conclusion: The RGP contact lens provided visibility similar to or clearer than that obtained with other methods. Because of its ease of use and lower cost, use of the RGP contact lens is ideal during vitrectomy performed with a wide-angle viewing system.Keywords: contact lens, RGP, viscoelastic agent, vitrectomy, wide viewing system

  6. Lateral shear interferometry with holo shear lens

    Science.gov (United States)

    Joenathan, C.; Mohanty, R. K.; Sirohi, R. S.

    1984-12-01

    A simple method for obtaining lateral shear using holo shear lenses (HSL) has been discussed. This simple device which produces lateral shears in the orthogonal directions has been used for lens testing. The holo shear lens is placed at or near the focus of the lens to be tested. It has also been shown that HSL can be used in speckle shear interferometry as it performs both the functions of shearing and imaging.

  7. An inverse and analytic lens design method

    OpenAIRE

    Lu, Yang; Lakshminarayanan, Vasudevan

    2016-01-01

    Traditional lens design is a numerical and forward process based on ray tracing and aberration theory. This method has limitations because the initial configuration of the lens has to be specified and the aberrations of the lenses have to considered. This paper is an initial attempt to investigate an analytic and inverse lens design method, called Lagrange, to overcome these barriers. Lagrange method tries to build differential equations in terms of the system parameters and the system input ...

  8. The lens and source of the optical Einstein ring gravitational lens ER 0047-2808

    OpenAIRE

    Wayth, Randall B.; Warren, Stephen J.; Lewis, Geraint F.; Hewett, Paul C.

    2004-01-01

    (Abridged) We perform a detailed analysis of the optical gravitational lens ER 0047-2808 imaged with WFPC2 on the Hubble Space Telescope. Using software specifically designed for the analysis of resolved gravitational lens systems, we focus on how the image alone can constrain the mass distribution in the lens galaxy. We find the data are of sufficient quality to strongly constrain the lens model with no a priori assumptions about the source. Using a variety of mass models, we find statistica...

  9. 五倍子水提取物清除牙科综合治疗椅水路生物膜的效果%The clearing effect of Chinese gallnut water extract on the biofilms in dental unit water lines

    Institute of Scientific and Technical Information of China (English)

    俞雪芬; 李聪; 王欣芝; 胡国庆

    2012-01-01

    Objective To evaluate the clearing effect of different concentration Chinese Gallnut water extract on the biofilms in dental unit water lines. Methods The dental unit water lines were divided into two groups. The biofilms in the two groups were cleared by different concentration Chinese Gallnut water extract (lOOmg/ml vs. 62.5mg/ml) for four weeks. The formation of biofilms were observed through laser confocal microscopy after they were dyed by fluorescent yellow at the first,second, third and fourth week after intervention. At the same time,the samples were collected in the cooling water for bacteria culture. Results Before intervention, there was no significant difference in the fluorescent intensity or the bacteria colonies in the cooling water between the two groups(P>0.05). After intervention,there were significant differences in the above index between the two groups (P<0.05). There was positive correlation between the bacteria colonies and the fluorescent intensity. Conclusion Chinese Gallnut water extract can effectively remove the biofilm. The removal efficiency is proportional to the concentration and time.%目的 评价不同浓度五倍子水提取物对牙科综合治疗椅水路生物膜的清除作用.方法 根据干预所用的五倍子水提取物浓度分为A组与B组,两组在实验起始点形成相同的生物膜后进行干预.每天治疗结束后,A组将浓度为100mg/ml的五倍子水提取物、B组将浓度为62.5mg/ml的五倍子水提取物,分别抽吸入综合治疗椅水道内,并保留至次晨,连续使用4周.分别于干预前及干预后1、2、3、4周时采样,荧光黄染色后激光共聚焦电镜观察生物膜的形成情况,照片进行定量分析,同时采集手机冷却水培养计数细菌菌落数.结果 生物膜荧光强度及细菌生长菌落数干预前两组比较,差异均无统计学意义(P>0.05);干预后同组不同时间点比较,差异均有统计学意义(P<0.05),组间比

  10. Distribution of salicylate in lens and intraocular fluids and its effect on cataract formation.

    Science.gov (United States)

    Cotlier, E; Sharma, Y R; Niven, T; Brescia, M

    1983-06-14

    Retrospective studies on cataract development in patients with rheumatoid arthritis or osteoarthritis revealed a retardant effect of aspirin on diabetic and non-diabetic cataracts. The effect of aspirin is dose-dependent. The correlation coefficient between years delay for various cataracts subcategories versus aspirin taken (in tablets per day X years of intake) was 0.69. The ocular pharmacokinetics of 14C acetylsalicylic acid or salicylate were determined after intravenous or intraperitoneal administration to rabbits. 14C acetylsalicylic acid penetrates rapidly into rabbit lens and aqueous humor after intravenous administration. After intraperitoneal administration, salicylate levels in rabbit plasma, similar to those of humans receiving four to six aspirin tablets (325 mg each), result in accumulation of salicylate by lens (mean +/- SD) of 405 +/- 72 mumoles/g and 620 +/- 30 mumoles/g at two and four hours, respectively. At those dosages, salicylate is cleared in 24 hours from rabbit plasma and intraocular fluids, but retained by lens. Penetration of salicylate into rabbit lens and rat lens is dose-dependent. The retardant aspirin effect in diabetic cataracts is linked to inhibition of tissue aldose reductase and lens protein glycosylation. Deceleration of galactose cataract formation in rats occurs after daily salicylate intraperitoneal injections of 100 mg/kg a day. PMID:6859071

  11. Simultaneous phacoemulsification, lens implantation and endothelial keratoplasty: Triple procedure

    Directory of Open Access Journals (Sweden)

    Nikolić Ljubiša

    2011-01-01

    Full Text Available Introduction. Simultaneous Descemet stripping endothelial keratoplasty, phacoemulsification, and intraocular lens implantation are indicated in Fuchs’ dystrophy with associated cataract. Compared to the standard method of the triple procedure which includes penetrating keratoplasty, this new method has the advantages of sutureless surgery, small limbal incision, faster recovery, less surface problems, less astigmatism, stronger tensile strength and more predictable calculation of the intraocular lens power. This is the first report of such a combination of procedures in our literature. Case report. A 76-year-old woman suffered from a gradual bilateral visual loss. The best corrected visual acuity was 20/60 (right eye and finger counting at 1m (left eye. Corneal thickness was 590 μm and 603 μm, respectively. A marked cornea guttata and nuclear cataract were present in both eyes. Phacoemulsification, lens implantation, and Descemet stripping were done in the left eye. The posterior lamellar corneal graft, 8.0 mm in diameter and about 150 μm thick, was bent and inserted through the limbal incision. The air was injected into the anterior chamber to attach the graft to the recipient stroma. The cornea remained clear, and the transplant was attached during a two-year follow-up. Visual acuity was 20/40 after two months, and 20/25 after one year. Conclusion. The new technique proved itself as a good choice for the treatment of a mild Fuchs’ dystrophy associated with cataract.

  12. Coculture with intraocular lens material-activated macrophages induces an inflammatory phenotype in lens epithelial cells.

    Science.gov (United States)

    Pintwala, Robert; Postnikoff, Cameron; Molladavoodi, Sara; Gorbet, Maud

    2015-03-01

    Cataracts are the leading cause of blindness worldwide, requiring surgical implantation of an intraocular lens. Despite evidence of leukocyte ingress into the postoperative lens, few studies have investigated the leukocyte response to intraocular lens materials. A novel coculture model was developed to examine macrophage activation by hydrophilic acrylic (poly(2-hydroxyethyl methacrylate)) and hydrophobic acrylic (polymethylmethacrylate) commercial intraocular lens. The human monocytic cell line THP-1 was differentiated into macrophages and cocultured with human lens epithelial cell line (HLE-B3) with or without an intraocular lens for one, two, four, or six days. Using flow cytometry and confocal microscopy, expression of the macrophage activation marker CD54 (intercellular adhesion molecule-1) and production of reactive oxygen species via the fluorogenic probe 2',7'-dichlorodihydrofluorescein diacetate were examined in macrophages. α-Smooth muscle actin, a transdifferentiation marker, was characterized in lens epithelial cells. The poly(2-hydroxyethyl methacrylate) intraocular lens prevented adhesion but induced significant macrophage activation (p intraocular lens), while the polymethylmethacrylate intraocular lens enabled adhesion and multinucleated fusion, but induced no significant activation. Coculture with either intraocular lens increased reactive oxygen species production in macrophages after one day (p intraocular lens, with hydrophilic surfaces inducing higher activation than hydrophobic surfaces. These findings provide a new method of inquiry into uveal biocompatibility, specifically through the quantification of cell-surface markers of leukocyte activation.

  13. CO2 Efflux from Cleared Mangrove Peat

    OpenAIRE

    Lovelock, Catherine E.; Roger W Ruess; Feller, Ilka C.

    2011-01-01

    BACKGROUND: CO(2) emissions from cleared mangrove areas may be substantial, increasing the costs of continued losses of these ecosystems, particularly in mangroves that have highly organic soils. METHODOLOGY/PRINCIPAL FINDINGS: We measured CO(2) efflux from mangrove soils that had been cleared for up to 20 years on the islands of Twin Cays, Belize. We also disturbed these cleared peat soils to assess what disturbance of soils after clearing may have on CO(2) efflux. CO(2) efflux from soils de...

  14. Paediatric intraocular lens implants: accuracy of lens power calculations.

    Science.gov (United States)

    O'Gallagher, M K; Lagan, M A; Mulholland, C P; Parker, M; McGinnity, G; McLoone, E M

    2016-09-01

    PurposeThis study aims to evaluate the accuracy of lens prediction formulae on a paediatric population.MethodsA retrospective case-note review was undertaken of patients under 8 years old who underwent cataract surgery with primary lens implantation in a regional referral centre for paediatric ophthalmology, excluding those whose procedure was secondary to trauma. Biometric and refractive data were analysed for 43 eyes, including prediction errors (PE). Statistical measures used included mean absolute error (MAE), median absolute error (MedAE), Student's t-test and Lin's correlation coefficient.ResultsThe mean PE using the SRK-II formula was +0.96 D (range -2.47D to +2.41 D, SD 1.33 D, MAE 1.38 D, MedAE 1.55, n=15). The mean PE was smaller using SRK/T (-0.18 D, range -3.25 D to +3.95 D, SD 1.70 D, MAE 1.30 D, MedAE 1.24, n=27). We performed an analysis of the biometry data using four different formula (Hoffer Q, Holladay 1, SRK-II and SRK/T). Hoffer Q showed a smaller MedAE than other formulae but also a myopic bias.ConclusionOur clinical data suggest SRK/T was more accurate in predicting post-operative refraction in this cohort of paediatric patients undergoing cataract surgery. Hoffer Q may have improved accuracy further.

  15. 27 CFR 9.99 - Clear Lake.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Clear Lake. 9.99 Section 9... TREASURY LIQUORS AMERICAN VITICULTURAL AREAS Approved American Viticultural Areas § 9.99 Clear Lake. (a) Name. The name of the viticultural area described in this section is “Clear Lake.” (b) Approved...

  16. 77 FR 66219 - Clearing Agency Standards

    Science.gov (United States)

    2012-11-02

    ... to clear credit default swaps. See Exchange Act Release Nos. 60372 (July 23, 2009), 74 FR 37748 (July 29, 2009), 61973 (Apr. 23, 2010), 75 FR 22656 (Apr. 29, 2010) and 63389 (Nov. 29, 2010), 75 FR 75520 (Dec. 3, 2010) (CDS clearing by ICE Clear Europe Limited); 60373 (July 23, 2009), 74 FR 37740 (July...

  17. Atom lens without chromatic aberrations

    CERN Document Server

    Efremov, Maxim A; Schleich, Wolfgang P

    2012-01-01

    We propose a lens for atoms with reduced chromatic aberrations and calculate its focal length and spot size. In our scheme a two-level atom interacts with a near-resonant standing light wave formed by two running waves of slightly different wave vectors, and a far-detuned running wave propagating perpendicular to the standing wave. We show that within the Raman-Nath approximation and for an adiabatically slow atom-light interaction, the phase acquired by the atom is independent of the incident atomic velocity.

  18. Flat lens for seismic waves

    CERN Document Server

    Brule, Stephane; Guenneau, Sebastien

    2016-01-01

    A prerequisite for achieving seismic invisibility is to demonstrate the ability of civil engineers to control seismic waves with artificially structured soils. We carry out large-scale field tests with a structured soil made of a grid consisting of cylindrical and vertical holes in the ground and a low frequency artificial source (< 10 Hz). This allows the identification of a distribution of energy inside the grid, which can be interpreted as the consequence of an effective negative refraction index. Such a flat lens reminiscent of what Veselago and Pendry envisioned for light opens avenues in seismic metamaterials to counteract the most devastating components of seismic signals.

  19. Intraocular lens with accommodation capacity

    OpenAIRE

    Dorronsoro, Carlos; Alejandre, Nicolás; Bekesi, Nandor; Marcos, Susana

    2014-01-01

    Intraocular lens with accommodation capacity comprising a first optical member (1) having a dynamic optical power, to which a second optical member (2) with a fixed optical power is affixed, in such a manner that at least a central part of each of one of one of the curved surfaces (2a, 2b) of the second optical member (2) and of at least one of the surfaces (1a, 1b) of the first optical member (1) are in contact with each other, the second optical member (2) and the first optical member (1) p...

  20. Controversies in intraocular lens implantation in pediatric uveitis.

    Science.gov (United States)

    Phatak, Sumita; Lowder, Careen; Pavesio, Carlos

    2016-12-01

    Cataract is one of the most common and visually debilitating complications of pediatric uveitis. It develops as a consequence of chronic inflammation and steroid use and is seen most often in juvenile idiopathic arthritis (JIA)-associated uveitis. Cataract extraction with intraocular lens (IOL) insertion has been carried out with a measure of success in non-uveitic pediatric eyes, but in cases of uveitis, multiple factors affect the final outcome. Chronic inflammation and its sequelae such as band keratopathy, posterior synechiae, and cyclitic membranes make surgical intervention more challenging and outcome less certain. Postoperative complications like increased inflammation, glaucoma, posterior capsular opacification, retrolental membranes, and hypotony may compromise the visual outcome. Early refractive correction is imperative in pediatric eyes to prevent amblyopia. The use of contact lenses and intraocular lenses in pediatric uveitic eyes were fraught with complications in the past. Surgical interventions such as vitreo-lensectomy followed by contact lens fitting and small incision cataract surgery followed by different types of intraocular lenses have been utilized, and many reports have been published, albeit in small patient groups. This review analyzes and discusses the existing literature on intraocular lens implantation in cases of pediatric uveitic cataract surgery. PMID:27009616

  1. Controversies in intraocular lens implantation in pediatric uveitis.

    Science.gov (United States)

    Phatak, Sumita; Lowder, Careen; Pavesio, Carlos

    2016-12-01

    Cataract is one of the most common and visually debilitating complications of pediatric uveitis. It develops as a consequence of chronic inflammation and steroid use and is seen most often in juvenile idiopathic arthritis (JIA)-associated uveitis. Cataract extraction with intraocular lens (IOL) insertion has been carried out with a measure of success in non-uveitic pediatric eyes, but in cases of uveitis, multiple factors affect the final outcome. Chronic inflammation and its sequelae such as band keratopathy, posterior synechiae, and cyclitic membranes make surgical intervention more challenging and outcome less certain. Postoperative complications like increased inflammation, glaucoma, posterior capsular opacification, retrolental membranes, and hypotony may compromise the visual outcome. Early refractive correction is imperative in pediatric eyes to prevent amblyopia. The use of contact lenses and intraocular lenses in pediatric uveitic eyes were fraught with complications in the past. Surgical interventions such as vitreo-lensectomy followed by contact lens fitting and small incision cataract surgery followed by different types of intraocular lenses have been utilized, and many reports have been published, albeit in small patient groups. This review analyzes and discusses the existing literature on intraocular lens implantation in cases of pediatric uveitic cataract surgery.

  2. 糖尿病合并白内障人工晶状体植入术后眼内炎的临床及预后分析%The clinical and prognosis of endophthalmitis of diabetes complicated with cataract extraction and intraocular lens implantation after operation

    Institute of Scientific and Technical Information of China (English)

    柴建廷; 段笃文; 王秀芳

    2014-01-01

    目的:探讨糖尿病合并白内障人工晶状体植入术后眼内炎的临床及预后。方法对我院眼科2008年1月-2013年5月收治的糖尿病合并白内障人工晶状体植入术后眼内炎6例进行临床分析。结果6例均行细菌培养+药敏试验,给予局部+全身抗感染治疗,4例行玻璃体切割+球内注药。术后1周视力:1例0.5,1例0.2,2例0.1,2例数指/20 cm。结论糖尿病合并白内障术后眼内炎患者的视力预后不良,对此类患者必须注重围术期的预防。%Objective To investigate the clinical and prognosis of endophthalmitis of diabetes complicated with cataract extraction and intraocular lens implantation after operation. Methods 6 patients with endophthalmitis were analyzed. Results Bacterial culture and drug sensitive test were made in 6 cases,and giving local and systemic anti infection thraphy.4 cases were treated with vitrectomy and ball injection.visual acuity of a week after operation (1 case 0.5;1 case 0.2;2 cases 0.1;2 cases/20cm).Conclusion The prognosis of diabetes complicated with cataract were bad,prevention must were made in peri-operation for such patients.

  3. Protection of the eye lens

    International Nuclear Information System (INIS)

    The limit of radiation exposure for eye lens is going to decrease dramatically from 150 to 20 mSv as a transposition into the French law of a CIPR (International Commission for Radiation Protection) directive. Sanitary studies have shown that radiologists are more likely by a factor of 3.8 to get eye lens opacities than the rest of the population. The wearing of protective glasses is recommended and in order to get a better monitoring of the radiation dose new dosimeters have been designed, they can be worn on the glass frame of directly stuck on the skin near the eyes. A study has shown that veterinary surgeons that are accustomed to stay near animals to keep them quiet during radiological exams are prone to receive high doses as well as physicians that use hypnosis to decrease the level of anxiety of their patients during radiological exams. Radiation exposure of radiologists can be mitigated through: the use of protective shields and equipment and the optimization of the dose delivered to the patient. (A.C.)

  4. Aldehyde dehydrogenase-derived omega-crystallins of squid and octopus. Specialization for lens expression.

    Science.gov (United States)

    Zinovieva, R D; Tomarev, S I; Piatigorsky, J

    1993-05-25

    omega-Crystallin of the octopus lens is related to aldehyde dehydrogenases (ALDH) of vertebrates (Tomarev, S. I., Zinovieva, R. D., and Piatigorsky, J. (1991) J. Biol. Chem. 266, 24226-24231) and ALDH1/eta-crystallin of elephant shrews (Wistow, G., and Kim, H. (1991) J. Mol. Evol. 32, 262-269). Only very low amounts of omega-crystallin are present in the squid lens. Here, we have cloned omega-crystallin cDNAs of the octopus (Octopus dofleini) and squid (Ommastrephes sloani pacificus) lenses. The deduced amino acid sequences of omega-crystallin from these species are 78% identical to each other, 56-58% identical to cytoplasmic ALDH1 and mitochondrial ALDH2 of vertebrates (which are 66-68% identical to each other), and 40% identical to Escherichia coli and spinach ALDHs. These data are consistent with the idea that the ALDH1/ALDH2 gene duplication in vertebrates occurred after divergence of cephalopods from the line giving rise to vertebrates, but before the separation of squid and octopus. Southern blot hybridization indicated that omega-crystallin is encoded by few genes (possibly just one) in octopus and squid. Northern blot hybridization revealed two bands (2.7 and 9.0 kilobases) of omega-crystallin RNA in the octopus lens and one band (4.2 kilobases) in the squid lens; omega-crystallin RNAs were undetectable in numerous non-lens tissues of octopus and squid, suggesting lens-specific expression of this gene(s). Finally, extracts of the octopus lens had no detectable ALDH activity using different substrates, consistent with omega-crystallin having no enzymatic activity. Taken together, our results suggest that omega-crystallin evolved by duplication of an ancestral gene encoding ALDH and subsequently specialized for refraction in the transparent lens while losing ALDH activity and expression in other tissues. PMID:7684383

  5. Contact lens sensors in ocular diagnostics.

    Science.gov (United States)

    Farandos, Nicholas M; Yetisen, Ali K; Monteiro, Michael J; Lowe, Christopher R; Yun, Seok Hyun

    2015-04-22

    Contact lenses as a minimally invasive platform for diagnostics and drug delivery have emerged in recent years. Contact lens sensors have been developed for analyzing the glucose composition of tears as a surrogate for blood glucose monitoring and for the diagnosis of glaucoma by measuring intraocular pressure. However, the eye offers a wider diagnostic potential as a sensing site and therefore contact lens sensors have the potential to improve the diagnosis and treatment of many diseases and conditions. With advances in polymer synthesis, electronics and micro/nanofabrication, contact lens sensors can be produced to quantify the concentrations of many biomolecules in ocular fluids. Non- or minimally invasive contact lens sensors can be used directly in a clinical or point-of-care setting to monitor a disease state continuously. This article reviews the state-of-the-art in contact lens sensor fabrication, their detection, wireless powering, and readout mechanisms, and integration with mobile devices and smartphones. High-volume manufacturing considerations of contact lenses are also covered and a case study of an intraocular pressure contact lens sensor is provided as an example of a successful product. This Review further analyzes the contact lens market and the FDA regulatory requirements for commercialization of contact lens sensors. PMID:25400274

  6. Optimization of Zoom Lens with Discrete State of Liquid Lens Elements by Using Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Cheng-Mu Tsai

    2015-01-01

    Full Text Available This paper is to employ liquid lens elements to design a lens with zoom function by using the genetic algorithm (GA optimization. The liquid lens elements used in the proposal can apply voltage adjustment to generate the electrical field that induces the liquid with electric conductivity to vary the surface curvature between two different kinds of liquids. According to the voltage level, the liquid lens element makes the discrete variation of the curvature and thickness realize the zoom function without moving the lens groups so that the overall length can be reduced. However, it is difficult to design the zoom lens under the discrete variation of the curvature and thickness in the liquid lens elements and the mechanical space that is constantly limited. The GA offers a flexible way for lens optimization. We regarded the spot size as the fitness function to look for the optimum curvatures, thickness, and the corresponding statuses of liquid lens elements for the zoom lens. As a result, the zoom lens with constant space can be realized by running the selection, crossover, and mutation operation in the GA optimization.

  7. All-dielectric subwavelength metasurface focusing lens.

    Science.gov (United States)

    West, Paul R; Stewart, James L; Kildishev, Alexander V; Shalaev, Vladimir M; Shkunov, Vladimir V; Strohkendl, Friedrich; Zakharenkov, Yuri A; Dodds, Robert K; Byren, Robert

    2014-10-20

    We have proposed, designed, manufactured and tested low loss dielectric micro-lenses for infrared (IR) radiation based on a dielectric metamaterial layer. This metamaterial layer was created by patterning a dielectric surface and etching to sub-micron depths. For a proof-of-concept lens demonstration, we have chosen a fine patterned array of nano-pillars with variable diameters. Gradient index (GRIN) properties were achieved by engineering the nano-pattern characteristics across the lens, so that the effective optical density of the dielectric metamaterial layer peaks around the lens center, and gradually drops at the lens periphery. A set of lens designs with reduced reflection and tailorable phase gradients have been developed and tested, demonstrating focal distances of a few hundred microns, beam area contraction ratio up to three, and insertion losses as low as 11%. PMID:25401653

  8. Dendritic immune cell densities in the central cornea associated with soft contact lens types and lens care solution types: a pilot study

    Directory of Open Access Journals (Sweden)

    Sindt CW

    2012-03-01

    Full Text Available Christine W Sindt1, Trudy K Grout1, D Brice Critser1, Jami R Kern2, David L Meadows21University of Iowa Hospitals and Clinics, Iowa City, IA; 2Alcon Research Ltd, Fort Worth, TX, USABackground: The purpose of this study was to assess whether differences in central corneal dendritic immune cell densities associated with combinations of soft contact lenses and lens care solutions could be detected by in vivo confocal microscopy.Methods: Participants were adults naïve to contact lens wear (n = 10 or who wore soft contact lenses habitually on a daily-wear schedule (n = 38 or on a study-assigned schedule for 30 days with daily disposable silicone hydrogel lenses (n = 15. Central corneas were scanned using an in vivo confocal microscope. Cell densities were compared among groups by demographic parameters, lens materials, and lens care solutions (polyhexamethylene biguanide [PHMB], polyquaternium-1 and myristamidopropyl dimethylamine [PQ/MAPD], peroxide, or blister pack solution [for daily disposable lenses].Results: Among lens wearers, no associations were observed between immune cell densities and age, gender, or years of lens-wearing experience. Mean cell density was significantly lower (P < 0.01 in nonwearers (29 ± 23 cells/mm2, n = 10 than in lens wearers (64 ± 71 cells/mm2, n = 53. Mean cell density was lower (P = 0.21 with traditional polymer lenses (47 ± 44 cells/mm2, n = 12 than with silicone hydrogel lenses (69 ± 77 cells/mm2, n = 41. Lowest to highest mean density of immune cells among lens wearers was as follows: PQ/MAPD solution (49 ± 28 cells/mm2, blister pack solution (63 ± 81 cells/mm2, PHMB solution (66 ± 44 cells/mm2, and peroxide solution (85 ± 112 cells/mm2.Conclusion: In this pilot study, in vivo confocal microscopy was useful for detecting an elevated immune response associated with soft contact lenses, and for identifying lens-related and solution-related immune responses that merit further research.Keywords: Clear Care

  9. New Management of Malignant Glaucoma by Phacoemulsification with Posterior Chamber Foldable Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    GeJian; GuoY

    1999-01-01

    Objective:To investigate the feasibility of phacoemulsification with posterior chamber foldable intraocular lens implantation in the management of malignant glaucoma. Patients and Methods:Fourteen patients with malignant glaucoma diagnosed in the Department of Glaucoma were enrolled in the study.12 patients developed malignant glaucoma after filtration surgery.1 developed after peripheral iridectomy.1 patient developed malignant glaucoma without any clear cause.Cataract phacoemulsification was performed.Posterior chamber intraocular foldable lens was implanted in 10 cases of patients.Results:All 14 patients were cured wiht normal intraocular pressure,normal anterior chamber depth and increased visual acuity.Conclusion:Phacoemulsification with posterior chamber foldable intraocular lens implantation is a good alternative in treating malignant glaucoma.

  10. 76 FR 45724 - Clearing Member Risk Management

    Science.gov (United States)

    2011-08-01

    ... COMMISSION 17 CFR Parts 1 and 23 RIN 3038-AD51 Clearing Member Risk Management AGENCY: Commodity Futures... extensive regulations addressing open access and risk management at the derivatives clearing organization (DCO) level.\\4\\ The Commission also has proposed regulations addressing risk management for...

  11. Internalization, Clearing and Settlement, and Liquidity

    NARCIS (Netherlands)

    Degryse, H.A.; van Achter, M.; Wuyts, G.

    2012-01-01

    Abstract: We study the relation between liquidity in financial markets and post-trading fees (i.e. clearing and settlement fees). The clearing and settlement agent (CSD) faces different marginal costs for different types of transactions. Costs are lower for an internalized transaction, i.e. when buy

  12. 17 CFR 39.4 - Procedures for implementing derivatives clearing organization rules and clearing new products.

    Science.gov (United States)

    2010-04-01

    ... product until its registration as a derivatives clearing organization is reinstated under the procedures... clearing a new product that is not traded on a designated contract market or a registered derivatives... of the product that make it acceptable for clearing with a certification that the clearing of...

  13. SNOW CLEARING SERVICE WINTER 2001-2002

    CERN Multimedia

    ST-HM Group; Tel. 72202

    2001-01-01

    As usual at this time of the year, the snowing clearing service, which comes under the control of the Transport Group (ST-HM), is preparing for the start of snow-clearing operations (timetable, stand-by service, personnel responsible for driving vehicles and machines, preparation of useful and necessary equipment, work instructions, etc.) in collaboration with the Cleaning Service (ST-TFM) and the Fire Brigade (TIS-FB). The main difficulty for the snow-clearing service is the car parks, which cannot be properly cleared because of the presence of CERN and private vehicles parked there overnight in different parts of the parking areas. The ST-HM Transport Group would therefore like to invite you to park vehicles together in order to facilitate the access of the snow ploughs, thus allowing the car parks to be cleared more efficiently before the personnel arrives for work in the mornings.

  14. Conjugate metamaterials and the perfect lens

    CERN Document Server

    Xu, Yadong; Xu, Lin; Chen, Huanyang

    2015-01-01

    In this letter, we show how transformation optics makes it possible to design what we call conjugate metamaterials. We show that these materials can also serve as substrates for making a subwavelength-resolution lens. The so-called "perfect lens", which is a lens that could focus all components of light (including propagating and evanescent waves), can be regarded as a limiting case, in which the respective conjugate metamaterials approach the characteristics of left-handed metamaterials, which have a negative refractive index.

  15. Cataract phacoemulsification with intraocular lens implantation after keratoprosthetics by Burn Vascular Leukoma (A case report

    Directory of Open Access Journals (Sweden)

    E.V. Kovshun,

    2014-01-01

    Full Text Available ABSTRACT Purpose. To evaluate the phacoemulsification (Phaco with intraocular lens (IOL implantation outcome after keratoprosthetics in patient with burn vascular leukoma. Material and methods. A patient, 39 years old, with a thinned burn vascular leukoma as a result of burns, limbal stem cell deficiency of both eyes, local simblefaron in the left eye (OS, secondary glaucoma (OS, after a simblefaron dissection and a glaucoma operation (OS, it was performed keratoprosthetics with a undismountable model of keratoprosthesis with an improvement in visual acuity (VA from 1/∞ рr. сerta up to 0.5 u/c. But there was a decrease in the VA to 0.01 u/c in 13 months. The aglia with vascularization and total overgrowth on the conjunctiva were observed on admission. Haptic keratoprostheses elements were not visible. Optical cylinder was clear. Anterior chamber depth was less than the average. A pronounced opacity of cortical layers of crystalline lens were defined. Fundus details were not visualized. A disturbance of topographic anatomical correlations in all structures of the anterior segment of the eye (ASE was revealed by the ultrasound bio-microscopy: corneal thickness — 1.47mm, anterior chamber depth in the central parts — 1.09mm, а lot of irido-corneal adhesions in the anterior chamber angle (ACA with anterior chamber closing by basal area of the iris, medium hypertrophy of the iris (0.43mm. The maximum size of the ciliary body was 0.74mm. Ciliary zonule fibers were heterogeneous: in three segments they were thickened, hypertrophied and with adhesions between them, in one segment lysed or fused with the iris. Posterior chamber dimensions were acutely asymmetrical. Anterior posterior size of lens w as 5.23mm. Despite the significant impairments of spatial relations in ASE structures in the patient the microinvasive Phaco with soft IOL implantation were carried out with the preventive purpose of possible complications during the highly traumatic

  16. 16 CFR 315.6 - Expiration of contact lens prescriptions.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Expiration of contact lens prescriptions... CONGRESS CONTACT LENS RULE § 315.6 Expiration of contact lens prescriptions. (a) In general. A contact lens... Commission, its employees, and its representatives. (3) No prescriber shall include an expiration date on...

  17. Bionic intraocular lens with variable focus and integrated structure

    Science.gov (United States)

    Liang, Dan; Wang, Xuan-Yin; Du, Jia-Wei; Xiang, Ke

    2015-10-01

    This paper proposes a bionic accommodating intraocular lens (IOL) for ophthalmic surgery. The designed lens has a solid-liquid mixed integrated structure, which mainly consists of a support ring, elastic membrane, rigid lens, and optical liquid. The lens focus can be adjusted through the deformation of the lens front surface when compressed. The integrated structure of the IOL is presented, as well as a detailed description of the lens materials and fabrication process. Images under different radial pressures are captured, and the lens deformation process, accommodating range, density, and optical property are analyzed. The designed lens achieves a 14.6 D accommodating range under a radial pressure of 51.4 mN and a 0.24 mm alteration of the lens outer radius. The deformation property of the lens matches well with the characteristic of the eye and shows the potential to help patients fully recover their vision accommodation ability after the cataract surgery.

  18. Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher

    Science.gov (United States)

    Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie

    2015-01-01

    Purpose To determine if the lens volume changes during accommodation. Methods The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. Results The mean (±SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were −0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Conclusions Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule. PMID:26161985

  19. RISK FACTORS FOR CONTACT LENS INDUCED PAPILLARY CONJUNCTIVITIS ASSOCIATED WITH SILICONE HYDROGEL CONTACT LENS WEAR

    Science.gov (United States)

    Tagliaferri, Angela; Love, Thomas E.; Szczotka-Flynn, Loretta

    2014-01-01

    BACKGROUND Contact lens induced papillary conjunctivitis (CLPC) continues to be a major cause of dropout during contact lens extended wear. This retrospective study explores risk factors for the development of CLPC during silicone hydrogel lens extended wear. METHODS Data from 205 subjects enrolled in the Longitudinal Analysis of Silicone Hydrogel Contact Lens (LASH) study wearing lotrafilcon A silicone hydrogel lenses for up to 30 days of continuous wear were used to determine risk factors for CLPC in this secondary analysis of the main cohort. The main covariates of interest included substantial lens-associated bacterial bioburden, and topographically determined lens base curve-to-cornea fitting relationships. Additional covariates of interest included history of prior adverse events, time of year, race, education level, gender and other subject demographics. Statistical analyses included univariate logistic regression to assess the impact of potential risk factors on the binary CLPC outcome, and Cox proportional hazards regression to describe the impact of those factors on time-to-CLPC diagnosis. RESULTS Across 12 months of follow-up, 52 subjects (25%) experienced CLPC. No associations were found between CLPC development and the presence of bacterial bioburden, lens-to-cornea fitting relationships, history of prior adverse events, gender or race. CLPC development followed the same seasonal trends as the local peaks in environmental allergans. CONCLUSIONS Lens fit and biodeposits, in the form of lens associated bacterial bioburden, were not associated with the development of CLPC during extended wear with lotrafilcon A silicone hydrogel lenses. PMID:24681609

  20. Methane Detector With Plastic Fresnel Lens

    Science.gov (United States)

    Grant, W. B.

    1986-01-01

    Laser detector for natural gas leaks modified by substitution of molded plastic lens for spherical mirror. By measuring relative attenuation at two wavelengths, detector used to check for methane escaping from pipelines above or below ground and from landfill.

  1. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  2. High Altitude Clear Air Turbulence Project

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Air Force Flight Dynamics Laboratory conducted the High Altitude Clear Air Turbulence Project in the mid 1960s with the intention of better understanding air...

  3. Ion clearing the the XLS-ring

    Energy Technology Data Exchange (ETDEWEB)

    Bozoki, E.S.; Halama, H.

    1990-01-01

    The mechanism of ion capture by the beam, their effects on the beam as well as ways to clear the ions are discussed. Special attention is given to these questions for the SXLS ring. 20 refs., 5 figs., 4 tabs.

  4. Ion clearing the the XLS-ring

    International Nuclear Information System (INIS)

    The mechanism of ion capture by the beam, their effects on the beam as well as ways to clear the ions are discussed. Special attention is given to these questions for the SXLS ring. 20 refs., 5 figs., 4 tabs

  5. komunikace značky Clean & Clear

    OpenAIRE

    Nováková, Kateřina

    2009-01-01

    The objective of this thesis is to describe a communication campaign of Clean & Clear brand. A brand owned by Johnson & Johnson company specializing in cosmetics for teenage girls. Campaign is described into details, evaluated in terms of effectiveness of its communication tools by achieving marketing goals over a specified period of time. This thesis should confirm the suitability and effectivity of the communication mix applied for Clean & Clear brand in a specific enviroment of anti-acne c...

  6. Governance of securities clearing and settlement systems

    OpenAIRE

    Daniela Russo; Terry L. Hart; Chryssa Papathanassiou

    2004-01-01

    In the context of securities clearing and settlement systems, the nature of governance arrangements acquires a dimension that goes beyond their traditional function in corporate law. They constitute a tool for regulators and central banks to achieve their respective policy goals relating to market operation, market integrity, and systemic stability. In the light of the analysis of this paper, and pending a further evolution in the regulation of securities clearing and settlement in the Commun...

  7. A Spectrometer Based on Diffractive Lens

    Institute of Scientific and Technical Information of China (English)

    WANG Daoyi; YAN Yingbai; JIN Guofan; WU Minxian

    2001-01-01

    A novel spectrometer is designed based on diffractive lens. It is essentially a flat field spectrometer. All the focal points are along the optical axis. Besides, all the asymmetrical aberrations vanish in our mounting. Thus low aberration can be obtained. In this article a diffractive lens is modeled as a special grating and analyzed by using a grating-based method. And a stigmatic point is introduced to reduce the aberrations.

  8. Environmental standards for intraocular lens implantation.

    Science.gov (United States)

    Crawford, B A; Kaufman, D V

    1984-02-01

    Successful implantation of prosthetic devices depends upon their freedom from postoperative inflammation and infection. Techniques and lessons learned in orthopaedic and other implant surgery should be applied to intraocular lens implantation. The avoidance of contamination by particles and micro-organisms is one essential principle of the surgical procedure. Practical steps are described to reduce both types of contamination. These measures taken together are recommended for adoption as a standard of environmental safety for lens implantation.

  9. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    OpenAIRE

    Elena Bonafonte Marquez; Sergio Bonafonte Royo

    2015-01-01

    We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL) implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for i...

  10. Introduction to the development of intraocular lens

    Science.gov (United States)

    Li, Yifan; Peng, Runling; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2013-08-01

    In order to cure the cataract disease or injuries in eyes, intraocular lens(IOL) has been studied all the time to replace the crystalline lens in human eyes. Researches on IOL are started early from 19th century, and it develops greatly in the hundreds years after. This article introduces several main kinds of IOLs that appear in the development history of IOL, and raises the double-liquid zoom IOL based on electrowetting, which will be the trend of IOL study.

  11. 23-gauge pars plana vitrectomy for management of posteriorly dislocated crystalline lens

    Directory of Open Access Journals (Sweden)

    Cho M

    2011-12-01

    Full Text Available Minhee Cho, RV Paul ChanWeill Cornell Medical College, Department of Ophthalmology, New York, NY, USAPurpose: Management of posteriorly dislocated crystalline lens has traditionally been performed with a standard 20-gauge vitrectomy system. This study demonstrates the use of a 23-gauge vitrectomy system for removal of retained lens fragments secondary to spontaneous dislocation or complicated cataract extraction.Methods: A retrospective, noncomparative, interventional consecutive case series at a single university medical center.Results: Fourteen eyes of 14 patients underwent a 23-gauge vitrectomy for removal of retained lens. Mean age was 75 years. Mean logMAR (logarithm of minimum angle of resolution visual acuity was 1.47 (Snellen equivalent 20/600 preoperatively and 0.37 (Snellen equivalent 20/50 postoperatively. A 20-gauge fragmatome was used in 64% of cases. The mean time to the best post-vitrectomy acuity was 4.9 weeks. The mean healing time was 25 days (6–48 days. Post-vitrectomy complications included choroidal detachment (two patients, vitreous hemorrhage (two patients, and acute ocular hypertension (two patients. The mean length of follow-up was 6.2 months (1–13 months.Conclusion: A 23-gauge vitrectomy system alone or in combination with the 20-gauge fragmatome is a safe and efficacious option for removal of dense posteriorly dislocated crystalline lens material.Keywords: lensectomy, retained lens, PPV

  12. A case of Alagille syndrome complicated by intraocular lens subluxation and rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    Fukumoto M

    2013-07-01

    Full Text Available Masanori Fukumoto, Tsunehiko Ikeda, Tetsuya Sugiyama, Mari Ueki, Takaki Sato, Eisuke Ishizaki Department of Ophthalmology, Osaka Medical College, Takatsuki City, Japan Abstract: This case report describes a case of Alagille syndrome with developing intraocular lens subluxation and rhegmatogenous retinal detachment 4 years after cataract surgery. A 15-year-old female patient with Alagille syndrome-associated cataracts in both eyes underwent phacoemulsification aspiration and intraocular lens implantation. Four years postoperative, intraocular lens subluxation developed in her left eye. For treatment, extraction of the dislocated intraocular lens, anterior vitrectomy, and intraocular lens fixation was performed. Three weeks later, the patient developed rhegmatogenous retinal detachment, which was well-treated by pars plana vitrectomy. Cataract surgery needs to be performed carefully in patients with Alagille syndrome due to the weakness of the zonule of Zinn. Careful postoperative observation is necessary for patients with Alagille syndrome who have undergone intraocular surgery in order to facilitate early detection of a possible rhegmatogenous retinal detachment. Keywords: Alagille syndrome, cataract, retina, surgery

  13. Combined 23-gauge sutureless vitrectomy and clear corneal phacoemulsification for rhegmatogenous retinal detachment repair

    Institute of Scientific and Technical Information of China (English)

    Hoseok; Moon; Hee; Jin; Sohn; Dea; Yeong; Lee; Jong; Yeon; Lee; Dong; Heun; Nam

    2015-01-01

    AIM: To assess the outcomes of combined 23-gauge sutureless vitrectomy and clear corneal phacoemulsification with intraocular lens implantation for rhegmatogenous retinal detachment(RRD) repair.METHODS: This was a retrospective, consecutive,noncomparative, interventional case series of 30 eyes of30 patients who underwent combined sutureless vitrectomy and clear corneal cataract surgery for the repair of RRD. The principal outcome measures were primary anatomical success rate, reasons for redetachment, final visual acuity, and surgical complications.RESULTS: Primary reattachment was achieved in 27eyes(90.0%). The reasons for redetachment(3 eyes, 10%)were incomplete laser retinopexy, persistent chronic subretinal fluid, and proliferative vitreoretinopathy,respectively. The logarithm of the minimum angle of resolution visual acuity(mean±SD) improved from 0.76±0.74 preoperatively to 0. 21 ± 0. 37 6 months’ postoperatively(P <0.0001). Postoperative hypotony was not detected,but 1 eye( 3. 3 %) had increased intraocular pressure(30 mm Hg) with spontaneous resolution. No endophthalmitis developed during follow-up. Macular pucker was detected in 3 eyes(10.0%).· CONCLUSION: Combined 23-gauge sutureless vitrectomy and clear corneal phacoemulsification with intraocular lens implantation for RRD repair was proven safe and effective. It may provide not only the known advantages of conventional combined surgery, but also additional advantages such as less conjunctival fibrosis and the maintenance of stable intraocular pressure with low risks of postoperative hypotony and intraocular pressure elevation.

  14. Specific eye-head coordination enhances vision in progressive lens wearers.

    Science.gov (United States)

    Rifai, Katharina; Wahl, Siegfried

    2016-09-01

    In uncorrected vision all combinations of eye and head positions are visually equivalent; thus, there is no need for a specific modification of eye-head coordination in young healthy observers. In contrast, the quality of visual input indeed strongly depends on eye position in the majority of healthy elderly drivers, namely in progressive additional lens (PALs) wearers. For a given distance, only specific combinations of eye and head position provide clear vision in a progressive lens wearer. However, although head movements are an integral part of gaze behavior, it is not known if eye-head coordination takes part in the enhancement of visual input in healthy individuals. In the current study we determined changes in eye-head coordination in progressive lens wearers in challenging tasks with high cognitive load, in the situation of driving. During a real-world drive on an urban round track in Stuttgart, gaze movements and head movements were measured in 17 PAL wearers and eye-head coordination was compared to 27 controls with unrestricted vision. Head movement behavior, specific to progressive lens wearers, was determined in head gain and temporal properties of head movements. Furthermore, vertical eye-head coordination was consistent only among PAL wearers. The observed differences in eye-head coordination clearly demonstrate a contribution of head movements in the enhancement of visual input in the healthy human visual system.

  15. Specific eye-head coordination enhances vision in progressive lens wearers.

    Science.gov (United States)

    Rifai, Katharina; Wahl, Siegfried

    2016-09-01

    In uncorrected vision all combinations of eye and head positions are visually equivalent; thus, there is no need for a specific modification of eye-head coordination in young healthy observers. In contrast, the quality of visual input indeed strongly depends on eye position in the majority of healthy elderly drivers, namely in progressive additional lens (PALs) wearers. For a given distance, only specific combinations of eye and head position provide clear vision in a progressive lens wearer. However, although head movements are an integral part of gaze behavior, it is not known if eye-head coordination takes part in the enhancement of visual input in healthy individuals. In the current study we determined changes in eye-head coordination in progressive lens wearers in challenging tasks with high cognitive load, in the situation of driving. During a real-world drive on an urban round track in Stuttgart, gaze movements and head movements were measured in 17 PAL wearers and eye-head coordination was compared to 27 controls with unrestricted vision. Head movement behavior, specific to progressive lens wearers, was determined in head gain and temporal properties of head movements. Furthermore, vertical eye-head coordination was consistent only among PAL wearers. The observed differences in eye-head coordination clearly demonstrate a contribution of head movements in the enhancement of visual input in the healthy human visual system. PMID:27604068

  16. Skin optical clearing potential of disaccharides.

    Science.gov (United States)

    Feng, Wei; Shi, Rui; Ma, Ning; Tuchina, Daria K; Tuchin, Valery V; Zhu, Dan

    2016-08-01

    Skin optical clearing can significantly enhance the ability of biomedical optical imaging. Some alcohols and sugars have been selected to be optical clearing agents (OCAs). In this work, we paid attention to the optical clearing potential of disaccharides. Sucrose and maltose were chosen as typical disaccharides to compare with fructose, an excellent monosaccharide-OCA, by using molecular dynamics simulation and an ex vivo experiment. The experimental results indicated that the optical clearing efficacy of skin increases linearly with the concentration for each OCA. Both the theoretical predication and experimental results revealed that the two disaccharides exerted a better optical clearing potential than fructose at the same concentration, and sucrose is optimal. Since maltose has an extremely low saturation concentration, the other two OCAs with saturation concentrations were treated topically on rat skin in vivo, and optical coherence tomography imaging was applied to monitor the optical clearing process. The results demonstrated that sucrose could cause a more significant increase in imaging depth and signal intensity than fructose. PMID:27108771

  17. CO2 efflux from cleared mangrove peat.

    Directory of Open Access Journals (Sweden)

    Catherine E Lovelock

    Full Text Available BACKGROUND: CO(2 emissions from cleared mangrove areas may be substantial, increasing the costs of continued losses of these ecosystems, particularly in mangroves that have highly organic soils. METHODOLOGY/PRINCIPAL FINDINGS: We measured CO(2 efflux from mangrove soils that had been cleared for up to 20 years on the islands of Twin Cays, Belize. We also disturbed these cleared peat soils to assess what disturbance of soils after clearing may have on CO(2 efflux. CO(2 efflux from soils declines from time of clearing from ∼10,600 tonnes km(-2 year(-1 in the first year to 3000 tonnes km(2 year(-1 after 20 years since clearing. Disturbing peat leads to short term increases in CO(2 efflux (27 umol m(-2 s(-1, but this had returned to baseline levels within 2 days. CONCLUSIONS/SIGNIFICANCE: Deforesting mangroves that grow on peat soils results in CO(2 emissions that are comparable to rates estimated for peat collapse in other tropical ecosystems. Preventing deforestation presents an opportunity for countries to benefit from carbon payments for preservation of threatened carbon stocks.

  18. Photon nanojet lens: design, fabrication and characterization

    Science.gov (United States)

    Xu, Chen; Zhang, Sichao; Shao, Jinhai; Lu, Bing-Rui; Mehfuz, Reyad; Drakeley, Stacey; Huang, Fumin; Chen, Yifang

    2016-04-01

    In this paper, a novel nanolens with super resolution, based on the photon nanojet effect through dielectric nanostructures in visible wavelengths, is proposed. The nanolens is made from plastic SU-8, consisting of parallel semi-cylinders in an array. This paper focuses on the lens designed by numerical simulation with the finite-difference time domain method and nanofabrication of the lens by grayscale electron beam lithography combined with a casting/bonding/lift-off transfer process. Monte Carlo simulation for injected charge distribution and development modeling was applied to define the resultant 3D profile in PMMA as the template for the lens shape. After the casting/bonding/lift-off process, the fabricated nanolens in SU-8 has the desired lens shape, very close to that of PMMA, indicating that the pattern transfer process developed in this work can be reliably applied not only for the fabrication of the lens but also for other 3D nanopatterns in general. The light distribution through the lens near its surface was initially characterized by a scanning near-field optical microscope, showing a well defined focusing image of designed grating lines. Such focusing function supports the great prospects of developing a novel nanolithography based on the photon nanojet effect.

  19. The lens equator: a platform for molecular machinery that regulates the switch from cell proliferation to differentiation in the vertebrate lens.

    Science.gov (United States)

    Mochizuki, Toshiaki; Masai, Ichiro

    2014-06-01

    The vertebrate lens is a transparent, spheroidal tissue, located in the anterior region of the eye that focuses visual images on the retina. During development, surface ectoderm associated with the neural retina invaginates to form the lens vesicle. Cells in the posterior half of the lens vesicle differentiate into primary lens fiber cells, which form the lens fiber core, while cells in the anterior half maintain a proliferative state as a monolayer lens epithelium. After formation of the primary fiber core, lens epithelial cells start to differentiate into lens fiber cells at the interface between the lens epithelium and the primary lens fiber core, which is called the equator. Differentiating lens fiber cells elongate and cover the old lens fiber core, resulting in growth of the lens during development. Thus, lens fiber differentiation is spatially regulated and the equator functions as a platform that regulates the switch from cell proliferation to cell differentiation. Since the 1970s, the mechanism underlying lens fiber cell differentiation has been intensively studied, and several regulatory factors that regulate lens fiber cell differentiation have been identified. In this review, we focus on the lens equator, where these regulatory factors crosstalk and cooperate to regulate lens fiber differentiation. Normally, lens epithelial cells must pass through the equator to start lens fiber differentiation. However, there are reports that when the lens epithelium structure is collapsed, lens fiber cell differentiation occurs without passing the equator. We also discuss a possible mechanism that represses lens fiber cell differentiation in lens epithelium.

  20. 76 FR 47529 - Customer Clearing Documentation and Timing of Acceptance for Clearing; Correction

    Science.gov (United States)

    2011-08-05

    ... Street, NW., Washington, DC 20581. SUPPLEMENTARY INFORMATION: In FR Doc. 2011-19365 appearing on page... COMMISSION 17 CFR Parts 1, 23, and 39 RIN 3038-AD51 Customer Clearing Documentation and Timing of Acceptance... August 1, 2011, regarding Customer Clearing Documentation and Timing of Acceptance for Clearing....

  1. Shanghai Clearing House to Roll out Renminbi-denominated Copper Clearing Operations in Free Trade Zone

    Institute of Scientific and Technical Information of China (English)

    2014-01-01

    <正>Clearing House Financial Markets Co.,Ltd.(Shanghai Clearing House)General Manager Xie Zhong told the media recently at the briefing of the international symposium of"Reform Deepening and Mechanism Innovation of the Post-crisis Kerb Market",Shanghai Clearing House will explore the feasibility of carrying out bond business in

  2. KIOM-79 Prevents Lens Epithelial Cell Apoptosis and Lens Opacification in Zucker Diabetic Fatty Rats

    Directory of Open Access Journals (Sweden)

    Junghyun Kim

    2011-01-01

    Full Text Available Damage of lens epithelial cells (LECs has been implicated in cataract formation. The aim of this study was to investigate the protective effect of KIOM-79, a combination of four plant extracts, on LECs. We examined the levels of advanced glycation end products (AGEs, nuclear factor-kappaB (NF-κB activation and inducible nitric oxide synthase (iNOS expression in LECs during cataract development using the Zucker diabetic fatty (ZDF rat, an animal model of type 2 diabetes. KIOM-79 was orally administered by gavage to ZDF rats once a day for 13 weeks. Apoptosis was detected by TUNEL assay, and NF-κB activation and iNOS expression were studied by southwestern histochemistry and immunohistochemistry, respectively. In diabetic cataractous lenses, TUNEL-positive LECs were markedly increased 20-fold, and AGEs were highly accumulated (2.7-fold in LECs. In addition, both NF-κB activation, and iNOS expression were significantly enhanced 3- to 5-fold, respectively, compared to levels found in normal ZL rats. However, the administration of KIOM-79 delayed the development of diabetic cataracts and prevented LEC apoptosis (70% through the inhibition of AGEs, NF-κB-activation and iNOS expression. These observations suggest that KIOM-79 is useful in inhibiting diabetic cataractogenesis and acts through an antiapoptotic mechanism to protect LECs from injury.

  3. [Results of intraocular lens implantation in cataract complicated by medium and high myopia].

    Science.gov (United States)

    Plotnikova, Iu A; Chuprov, A D; Volkov, D V

    2001-01-01

    Results of surgical treatment of cataract complicated by medium and high myopia are analyzed. The main group consisted of 90 patients (96 eyes) subjected to extracapsular cataract extraction with implantation of posterior-chamber intraocular lenses and the reference group of 128 patients in whom cataract was extracted without implantation of artificial lens. The study included creation of a mathematical model of myopic eye with estimation of pressure fluctuations in various zones of the eye, developing during transposition of the vitreous during patient's movements (head movements, jumps, falling) and the damping effect of the lens in the ocular system. It was proven by mathematical calculations that transpositions of jelly fractions of the vitreous decreased by 70% in an eye with the lens in comparison with their transposition in aphakia. Clinical studies demonstrated the efficiency of intraocular correction of aphakia in high myopia: implantation of an intraocular lens decreases the risk of detachment of the retina during the postoperative period and helps attain the desired refraction. PMID:11765458

  4. A medieval fallacy: the crystalline lens in the center of the eye

    Directory of Open Access Journals (Sweden)

    Leffler CT

    2016-04-01

    Full Text Available Christopher T Leffler,1 Tamer M Hadi,2 Akrithi Udupa,1 Stephen G Schwartz,3 Daniel Schwartz1 1Department of Ophthalmology, Virginia Commonwealth University, Richmond, VA, 2Graduate School of Medicine, University of Tennessee Medical Center, Knoxville, TN, 3Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA Objective: To determine whether, as most modern historians have written, ancient Greco-Roman authors believed the crystalline lens is positioned in the center of the eye. Background: Historians have written that statements about cataract couching by Celsus, or perhaps Galen of Pergamon, suggested a centrally located lens. Celsus specifically wrote that a couching needle placed intermediate between the corneal limbus and the lateral canthus enters an empty space, presumed to represent the posterior chamber. Methods: Ancient ophthalmic literature was analyzed to understand where these authors believed the crystalline lens was positioned. In order to estimate where Celsus proposed entering the eye during couching, we prospectively measured the distance from the temporal corneal limbus to the lateral canthus in 30 healthy adults. Results: Rufus of Ephesus and Galen wrote that the lens is anterior enough to contact the iris. Galen wrote that the lens equator joins other ocular structures at the corneoscleral junction. In 30 subjects, half the distance from the temporal corneal limbus to the lateral canthus was a mean of 4.5 mm (range: 3.3–5.3 mm. Descriptions of couching by Celsus and others are consistent with pars plana entry of the couching needle. Anterior angulation of the needle would permit contact of the needle with the lens. Conclusion: Ancient descriptions of anatomy and couching do not establish the microanatomic relationships of the ciliary region with any modern degree of accuracy. Nonetheless, ancient authors, such as Galen and Rufus, clearly understood that the lens is located anteriorly

  5. Gravitational binary-lens events with prominent effects of lens orbital motion

    Energy Technology Data Exchange (ETDEWEB)

    Park, H.; Han, C.; Choi, J.-Y. [Department of Physics, Institute for Astrophysics, Chungbuk National University, Cheongju 371-763 (Korea, Republic of); Udalski, A.; Szymański, M. K.; Kubiak, M.; Soszyński, I.; Pietrzyński, G.; Poleski, R.; Ulaczyk, K.; Pietrukowicz, P.; Kozłowski, S.; Skowron, J.; Wyrzykowski, Ł. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Gould, A.; Gaudi, B. S. [Department of Astronomy, The Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Beaulieu, J.-P. [Institut d' Astrophysique de Paris, UMR 7095 CNRS-Université Pierre and Marie Curie, 98bis Bd Arago, F-75014 Paris (France); Tsapras, Y. [Las Cumbres Observatory Global Telescope Network, 6740 Cortona Drive, Suite 102, Goleta, CA 93117 (United States); Depoy, D. L. [Department of Physics and Astronomy, Texas A and M University, College Station, TX 77843 (United States); Dong, Subo [Institute for Advanced Study, Einstein Drive, Princeton, NJ 08540 (United States); Collaboration: OGLE Collaboration; μFUN Collaboration; PLANET Collaboration; RoboNet Collaboration; and others

    2013-12-01

    Gravitational microlensing events produced by lenses composed of binary masses are important because they provide a major channel for determining physical parameters of lenses. In this work, we analyze the light curves of two binary-lens events, OGLE-2006-BLG-277 and OGLE-2012-BLG-0031, for which the light curves exhibit strong deviations from standard models. From modeling considering various second-order effects, we find that the deviations are mostly explained by the effect of the lens orbital motion. We also find that lens parallax effects can mimic orbital effects to some extent. This implies that modeling light curves of binary-lens events not considering orbital effects can result in lens parallaxes that are substantially different from actual values and thus wrong determinations of physical lens parameters. This demonstrates the importance of routine consideration of orbital effects in interpreting light curves of binary-lens events. It is found that the lens of OGLE-2006-BLG-277 is a binary composed of a low-mass star and a brown dwarf companion.

  6. The Sloan Lens ACS Survey. V. The full ACS strong-lens sample

    NARCIS (Netherlands)

    Bolton, Adam S.; Burles, Scott; Koopmans, Leon V. E.; Treu, Tommaso; Gavazzi, Raphael; Moustakas, Leonidas A.; Wayth, Randall; Schlegel, David J.

    2008-01-01

    We present the definitive data for the full sample of 131 strong gravitational lens candidates observed with the Advanced Camera for Surveys (ACS) aboard the Hubble Space Telescope by the Sloan Lens ACS (SLACS) Survey. All targets were selected for higher redshift emission lines and lower redshift c

  7. Effect of infusion bottle height on lens power after lens refilling with and without a plug

    NARCIS (Netherlands)

    Koopmans, SA; Terwee, T; Haitjema, HJ; Kooijman, AC; Barkhof, J

    2003-01-01

    Purpose: To evaluate the influence of intraoperative infusion bottle height on the power of refilled pig lenses. Setting: Research Laboratory, Pharmacia Intraocular Lens Manufacturing Plant, Groningen, The Netherlands. Methods: This study comprised 2 groups of pig eyes. In 1 group, the lens was refi

  8. Clear plastic cups: a childhood choking hazard.

    Science.gov (United States)

    Weiss, R L; Goldstein, M N; Dharia, A; Zahtz, G; Abramson, A L; Patel, M

    1996-11-01

    The disposable plastic beverage cup is not usually regarded as hazardous to young children. Certain varieties of these products however, are manufactured from a brittle, clear plastic that easily cracks and fragments. While most conscientious parents keep their children safe from peanuts, balloons, and other known choking hazards, a child can surreptitiously bite a cup edge and aspirate the fragment. We report two cases of foreign body aspiration involving clear plastic cups that went undetected one of which remained 21 months following a negative rigid bronchoscopy. Diagnostic difficulties are related to the transparency and radiolucency of these objects. When suspicious of foreign body aspiration in children, otolaryngologists should inquire about the availability of clear plastic cups in the household and be mindful of the diagnostic pitfalls. Further investigations including CT scanning and repeat bronchoscopy may be helpful in cases of suspected missed foreign bodies. An educational campaign aimed at prevention and placement of product package warning labels should be established.

  9. The debts' clearing problem: a new approach

    CERN Document Server

    Pătcaş, C

    2011-01-01

    The debts' clearing problem is about clearing all the debts in a group of $n$ entities (e.g. persons, companies) using a minimal number of money transaction operations. In our previous works we studied the problem, gave a dynamic programming solution solving it and proved that it is NP-hard. In this paper we adapt the problem to dynamic graphs and give a data structure to solve it. Based on this data structure we develop a new algorithm, that improves our previous one for the static version of the problem.

  10. Oral Cavity Clear Cell Odontogenic Carcinoma.

    Science.gov (United States)

    Ginat, Daniel Thomas; Villaflor, Victoria; Cipriani, Nicole A

    2016-06-01

    A case of clear cell odontogenic carcinoma of the oral cavity is described in this sine qua non radiology-pathology correlation article. CT demonstrated a solid and cystic mass arising from the mandible. Histology demonstrated variably-sized nests of clear to pale eosinophilic cells with occasional central necrosis embedded in a hyalinized to fibrocellular stroma. The specimen was also positive for the characteristic rearrangement of the EWSR1 (22q12) locus in 93.5 % of interphase cells. PMID:25994920

  11. Clear cell carcinoma of the female genital tract (not everything is as clear as it seems).

    Science.gov (United States)

    Offman, Saul L; Longacre, Teri A

    2012-09-01

    Clear cell carcinoma has a storied history in the female genital tract. From the initial designation of ovarian clear cell adenocarcinoma as "mesonephroma" to the linkage between vaginal clear cell carcinoma and diethylstilbestrol exposure in utero, gynecologic tract clear cell tumors have puzzled investigators, posed therapeutic dilemmas for oncologists, and otherwise presented major differential diagnostic challenges for pathologists. One of the most common errors in gynecologic pathology is misdiagnosis of clear cell carcinoma, on both frozen section and permanent section. Given the poor response to platinum-based chemotherapy for advanced-stage disease and increased risk of thromboembolism, accurate diagnosis of clear cell carcinoma is important in the female genital tract. This review (1) presents the clinical and pathologic features of female genital tract clear cell carcinomas; (2) highlights recent molecular developments; (3) identifies areas of potential diagnostic confusion; and (4) presents solutions for these diagnostic problems where they exist.

  12. Optical integration of Pancharatnam-Berry phase lens and dynamical phase lens

    Science.gov (United States)

    Ke, Yougang; Liu, Yachao; Zhou, Junxiao; Liu, Yuanyuan; Luo, Hailu; Wen, Shuangchun

    2016-03-01

    In the optical system, most elements such as lens, prism, and optical fiber are made of silica glass. Therefore, integrating Pancharatnam-Berry phase elements into silica glass has potential applications in the optical system. In this paper, we take a lens, for example, which integrates a Pancharatnam-Berry phase lens into a conventional plano-convex lens. The spin states and positions of focal points can be modulated by controlling the polarization states of the incident beam. The proposed lens has a high transmission efficiency, and thereby acts as a simple and powerful tool to manipulate spin photons. Furthermore, the method can be conveniently extended to the optical fiber and laser cavity, and may provide a route to the design of the spin-photonic devices.

  13. The management of clear cell sarcoma

    NARCIS (Netherlands)

    Kuiper, DR; Hoekstra, HJ; Veth, RPH; Wobbes, T

    2003-01-01

    Clear cell sarcoma is a rare soft tissue tumour, constituting approximately 1% of all soft tissue sarcomas. Prognosis is reported to be poor due to the great propensity to metastasise regionally and distantly. In this paper, we report the surgical experience of two university hospitals. Both disease

  14. Lake Mead--clear and vital

    Science.gov (United States)

    Wessells, Stephen M.; Rosen, Michael

    2013-01-01

    “Lake Mead – Clear and Vital” is a 13 minute documentary relating the crucial role of science in maintaining high water quality in Lake Mead. The program was produced coincident with release of the Lakes Mead and Mohave Circular a USGS publication covering past and on-going research in the lakes and tributaries of the Lake Mead National Recreation Area.

  15. Small Incision Cataract Surgery (SICS with Clear Corneal Incision and SICS with Scleral Incision – A Comparative Study

    Directory of Open Access Journals (Sweden)

    Md Shafiqul Alam

    2014-01-01

    Full Text Available Background: Age related cataract is the leading cause of blindness and visual impairment throughout the world. With the advent of microsurgical facilities simple cataract extraction surgery has been replaced by small incision cataract surgery (SICS with posterior chamber intra ocular lens implant, which can be done either with clear corneal incision or scleral incision. Objective: To compare the post operative visual outcome in these two procedures of cataract surgery. Materials and method: This comparative study was carried out in the department of Ophthalmology, Delta Medical College & Hospital, Dhaka, Bangladesh, during the period of January 2010 to December 2012. Total 60 subjects indicated for age related cataract surgery irrespective of sex with the age range of 40-80 years with predefined inclusion and exclusion criteria were enrolled in the study. Subjects were randomly and equally distributed in 2 groups; Group A for SICS with clear corneal incision and group B for SICS with scleral incision. Post operative visual out come was evaluated by determining visual acuity and astigmatism in different occasions and was compared between groups. Statistical analysis was done by SPSS for windows version12. Results: The highest age incidence (43.3% was found between 61 to 70 years of age group. Among study subjects 40 were male and 20 were female. Preoperative visual acuity and astigmatism were evenly distributed between groups. Regarding postoperative unaided visual outcome, 6/12 or better visual acuity was found in 19.98% cases in group A and 39.6% cases in group B at 1st week. At 6th week 6/6 vision was found in 36.3% in Group A and 56.1% in Group B and 46.2% in group A and 66% in group B without and with correction respectively. With refractive correction, 6/6 vision was attained in 60% subjects of group A and 86.67% of group B at 8th week. Post operative visual acuity was statistically significant in all occasions. Postoperative astigmatism of

  16. [Representation and mathematical analysis of human crystalline lens].

    Science.gov (United States)

    Tălu, Stefan; Giovanzana, Stefano; Tălu, Mihai

    2011-01-01

    The surface of human crystalline lens can be described and analyzed using mathematical models based on parametric representations, used in biomechanical studies and 3D solid modeling of the lens. The mathematical models used in lens biomechanics allow the study and the behavior of crystalline lens on variables and complex dynamic loads. Also, the lens biomechanics has the potential to improve the results in the development of intraocular lenses and cataract surgery. The paper presents the most representative mathematical models currently used for the modeling of human crystalline lens, both optically and biomechanically.

  17. Design and fabrication of soft zoom lens

    Science.gov (United States)

    Lin, Wei-Cheng; Chen, Chao-Chang A.; Huang, Kuo-Cheng

    2008-08-01

    With minimization of optical-electronics devices, conventional optical zoom lens component has been explored with liquid lens and soft polymer membranes. This paper introduces a novel zoom lens system with a soft polymer material, Polydimethylsiloxane (PDMS), its shape and curvature can be controlled by pneumatic pressure. Therefore, effective focal length (EFL) of soft zoom lens (SZL) system can be controlled and altered. According to desired opto-mechanical design, this ZL has been accessed to determine the optical specifications. After the pressure activated from 0 to 0.02MPa, the change of EFL of the SZL system can reach up to 18.77% (33.44mm to 39.717mm). Experimental results show that zoom effects of the developed SZL system are significantly affected by the shape, thickness and curing parameter of PDMS soft lens. The SZL system has been verified with the function of zoom ability. Further research works on the integration of the SZL system with imaging system for mobile devices or robot vision applications.

  18. Models of the Cosmic Horseshoe Gravitational Lens

    CERN Document Server

    Dye, Simon; Belokurov, V; Warren, S J; Hewett, P

    2008-01-01

    We model the extremely massive and luminous lens galaxy in the Cosmic Horseshoe Einstein ring system, recently discovered in the Sloan Digital Sky Survey. We use the semi-linear method of Warren & Dye (2003), which pixelises the source surface brightness distribution, to invert the Einstein ring for sets of parameterised lens models. Here, the method is refined by exploiting Bayesian inference to optimise adaptive pixelisation of the source plane and to choose between three differently parameterised models: a singular isothermal ellipsoid, a power law model and a NFW profile. The most probable lens model is the power law with a volume mass density that scales as r^(-1.96+/-0.02) and an axis ratio of ~0.8. The mass within the Einstein ring (i.e., within a cylinder with projected distance of ~30 kpc from the centre of the lens galaxy) is (5.02+/-0.09)*10^12 M_solar, and the mass-to-light ratio is ~30. Even though the lens lies in a group of galaxies, the preferred value of the external shear is almost zero....

  19. Apoptosis in the lens anlage of the heritable lens aplastic mouse (lap mouse).

    Science.gov (United States)

    Aso, S; Tashiro, M; Baba, R; Sawaki, M; Noda, S; Fujita, M

    1998-08-01

    Adult homozygous lap mice show various eye abnormalities, such as aphakia, retinal disorganization, and dysplasia of the cornea and anterior chamber. In the fetal eye of a homozygous lap mouse, the lens placode seems to develop normally. However, the lens vesicle progresses abnormally to form a mass of cells without a cavity, and the mass vanishes soon afterward. We examined cell death in the lens anlage of this mutant. The lens anlagen of homozygous lap and normal mice from days 10 to 12 of gestation were observed by light microscopy after DNA end-labeling by immunohistochemistry and by transmission electron microscopy. By light microscopy, a slight frequency of cell death was detected in the lens anlage encircling the surface ectoderm and in the anlage or in the anlage of both homozygous lap mice and normal mice at day 10 of gestation. Cell death was seen in the lens anlage encircling the surface ectoderm in the normal mouse and sporadically in the anlage of the homozygous lap mouse at day 10.5 of gestation. Cell death was visible at the area of the lens vesicle attached to the surface ectoderm and encircling the surrounding surface ectoderm in the normal mouse, and in the lens anlage encircling the surface ectoderm and the apex areas of the lens anlage in the homozygous lap mouse at day 11 of gestation. At day 12 of gestation, almost no cell death was observed in the lens anlage of the normal mouse. However, extensive areas of cell death were still seen in the lens anlage at its apex, at the inner region, and encircling the surface ectoderm in the homozygous lap mouse. Electron microscopic observation showed that the dead cells observed in the lens anlagen by light microscopy in normal and lap mice are the result of apoptosis. In lap mice, cells with cytoplasmic condensation were observed mainly at days 10 and 10.5 of gestation. Many apoptotic bodies which had been phagocytosed by adjacent cells were seen predominantly at day 11 of gestation. At day 12 of

  20. Efficient flat metasurface lens for terahertz imaging.

    Science.gov (United States)

    Yang, Quanlong; Gu, Jianqiang; Wang, Dongyang; Zhang, Xueqian; Tian, Zhen; Ouyang, Chunmei; Singh, Ranjan; Han, Jiaguang; Zhang, Weili

    2014-10-20

    Metamaterials offer exciting opportunities that enable precise control of amplitude, polarization and phase of the light beam at a subwavelength scale. A gradient metasurface consists of a class of anisotropic subwavelength metamaterial resonators that offer abrupt amplitude and phase changes, thus enabling new applications in optical device design such as ultrathin flat lenses. We propose a highly efficient gradient metasurface lens based on a metal-dielectric-metal structure that operates in the terahertz regime. The proposed structure consists of slotted metallic resonator arrays on two sides of a thin dielectric spacer. By varying the geometrical parameters, the metasurface lens efficiently manipulates the spatial distribution of the terahertz field and focuses the beam to a spot size on the order of a wavelength. The proposed flat metasurface lens design is polarization insensitive and works efficiently even at wide angles of incidence. PMID:25401626

  1. The Frontier Fields Lens Modeling Comparison Project

    CERN Document Server

    Meneghetti, M; Coe, D; Contini, E; De Lucia, G; Giocoli, C; Acebron, A; Borgani, S; Bradac, M; Diego, J M; Hoag, A; Ishigaki, M; Johnson, T L; Jullo, E; Kawamata, R; Lam, D; Limousin, M; Liesenborgs, J; Oguri, M; Sebesta, K; Sharon, K; Williams, L L R; Zitrin, A

    2016-01-01

    Gravitational lensing by clusters of galaxies offers a powerful probe of their structure and mass distribution. Deriving a lens magnification map for a galaxy cluster is a classic inversion problem and many methods have been developed over the past two decades to solve it. Several research groups have developed techniques independently to map the predominantly dark matter distribution in cluster lenses. While these methods have all provided remarkably high precision mass maps, particularly with exquisite imaging data from the Hubble Space Telescope (HST), the reconstructions themselves have never been directly compared. In this paper, we report the results of comparing various independent lens modeling techniques employed by individual research groups in the community. Here we present for the first time a detailed and robust comparison of methodologies for fidelity, accuracy and precision. For this collaborative exercise, the lens modeling community was provided simulated cluster images -- of two clusters Are...

  2. An inverse and analytic lens design method

    CERN Document Server

    Lu, Yang

    2016-01-01

    Traditional lens design is a numerical and forward process based on ray tracing and aberration theory. This method has limitations because the initial configuration of the lens has to be specified and the aberrations of the lenses have to considered. This paper is an initial attempt to investigate an analytic and inverse lens design method, called Lagrange, to overcome these barriers. Lagrange method tries to build differential equations in terms of the system parameters and the system input and output (object and image). The generalized Snell's law in three dimensional space and the normal of a surface in fundamental differential geometry are applied. Based on the Lagrange method equations for a single surface system are derived which can perfectly image a point object.

  3. Laser light scattering in eye lens model

    Science.gov (United States)

    Larionova, Nadezhda L.; Maksimova, Irina L.; Kochubey, Vyacheslav I.

    2000-11-01

    Theoretical investigations of laser light radiation scattered by eye lens model as a system of spheres with various parameters were performed on the base of Mie theory of electromagnetic scattering by a single sphere. The calculations were performed for systems of particles whose coordinates were specifically realized in random fashion according to the specified probabilities defined by the approximation of hard spheres. The modeling of lens biotissue was carried out by using of medical data about internal structure of lens of human and some animals. In general the researchable model presents the system of homogeneous spherical particles those are randomly distributed in the layer of thickness. We study the optical properties such as scattering effective cross-section and function of correlation in different models.

  4. Catadioptric aberration correction in cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M. [IBM T.J. Watson Research Center, PO Box 218, Yorktown Heights, NY 10598 (United States); Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-04-15

    In this paper I briefly review the use of electrostatic electron mirrors to correct the aberrations of the cathode lens objective lens in low energy electron microscope (LEEM) and photo electron emission microscope (PEEM) instruments. These catadioptric systems, combining electrostatic lens elements with a reflecting mirror, offer a compact solution, allowing simultaneous and independent correction of both spherical and chromatic aberrations. A comparison with catadioptric systems in light optics informs our understanding of the working principles behind aberration correction with electron mirrors, and may point the way to further improvements in the latter. With additional developments in detector technology, 1 nm spatial resolution in LEEM appears to be within reach. - Highlights: • The use of electron mirrors for aberration correction in LEEM/PEEM is reviewed. • A comparison is made with similar systems in light optics. • Conditions for 1 nm spatial resolution are discussed.

  5. Catadioptric aberration correction in cathode lens microscopy

    International Nuclear Information System (INIS)

    In this paper I briefly review the use of electrostatic electron mirrors to correct the aberrations of the cathode lens objective lens in low energy electron microscope (LEEM) and photo electron emission microscope (PEEM) instruments. These catadioptric systems, combining electrostatic lens elements with a reflecting mirror, offer a compact solution, allowing simultaneous and independent correction of both spherical and chromatic aberrations. A comparison with catadioptric systems in light optics informs our understanding of the working principles behind aberration correction with electron mirrors, and may point the way to further improvements in the latter. With additional developments in detector technology, 1 nm spatial resolution in LEEM appears to be within reach. - Highlights: • The use of electron mirrors for aberration correction in LEEM/PEEM is reviewed. • A comparison is made with similar systems in light optics. • Conditions for 1 nm spatial resolution are discussed

  6. A Luneburg lens in moving coordinates

    Science.gov (United States)

    Gladyshev, V. O.; Tereshin, A. A.

    2016-05-01

    The reflection of light rays by a reference microsatellite of new design, which moves with a velocity of 7500 m/s along a near-Earth orbit with a radius of 835 km, is calculated. The microsatellite is a bilayer Luneburg lens with an outer radius of 85 mm. The process of propagation of electromagnetic radiation in a Luneburg lens is analyzed for the first time with the effects of electrodynamics of moving media and optical glass dispersion taken into account. It is demonstrated that the lens motion leads to additional deflection and mixing of rays with various angles of incidence. The obtained results allow one to improve the accuracy of determination of satellite coordinates and open up new opportunities for tests of the theory of relativity and electrodynamics.

  7. Social Norms and Behavior in the Local Commons Through the Lens of Field Experiments

    OpenAIRE

    Cardenas, Juan-Camilo

    2009-01-01

    Behavior in the local commons is usually embedded in a context of regulations and social norms that the group of users face. Such norms and rules affect how individuals value material and non-material incentives and therefore determine their decision to cooperate or over extract the resources from the common-pool. This paper discusses the importance of social norms in shaping behavior in the commons through the lens of experiments, and in particular experiments conducted in the field with peo...

  8. Eye lens dose in interventional cardiology.

    Science.gov (United States)

    Principi, S; Delgado Soler, C; Ginjaume, M; Beltran Vilagrasa, M; Rovira Escutia, J J; Duch, M A

    2015-07-01

    The ICRP has recently recommended reducing the occupational exposure dose limit for the lens of the eye to 20 mSv y(-1), averaged over a period of 5 y, with no year exceeding 50 mSv, instead of the current 150 mSv y(-1). This reduction will have important implications for interventional cardiology and radiology (IC/IR) personnel. In this work, lens dose received by a staff working in IC is studied in order to determine whether eye lens dose monitoring or/and additional radiological protection measures are required. Eye lens dose exposure was monitored in 10 physicians and 6 nurses. The major IC procedures performed were coronary angiography and percutaneous transluminal coronary angioplasty. The personnel were provided with two thermoluminescent dosemeters (TLDs): one calibrated in terms of Hp(3) located close to the left ear of the operator and a whole-body dosemeter calibrated in terms of Hp(10) and Hp(0.07) positioned on the lead apron. The estimated annual eye lens dose for physicians ranged between 8 and 60 mSv, for a workload of 200 procedures y(-1). Lower doses were collected for nurses, with estimated annual Hp(3) between 2 and 4 mSv y(-1). It was observed that for nurses the Hp(0.07) measurement on the lead apron is a good estimate of eye lens dose. This is not the case for physicians, where the influence of both the position and use of protective devices such as the ceiling shield is very important and produces large differences among doses both at the eyes and on the thorax. For physicians, a good correlation between Hp(3) and dose area product is shown. PMID:25809107

  9. Analytic Models of Plausible Gravitational Lens Potentials

    Energy Technology Data Exchange (ETDEWEB)

    Baltz, Edward A.; Marshall, Phil; Oguri, Masamune

    2007-05-04

    Gravitational lenses on galaxy scales are plausibly modeled as having ellipsoidal symmetry and a universal dark matter density profile, with a Sersic profile to describe the distribution of baryonic matter. Predicting all lensing effects requires knowledge of the total lens potential: in this work we give analytic forms for that of the above hybrid model. Emphasizing that complex lens potentials can be constructed from simpler components in linear combination, we provide a recipe for attaining elliptical symmetry in either projected mass or lens potential.We also provide analytic formulae for the lens potentials of Sersic profiles for integer and half-integer index. We then present formulae describing the gravitational lensing effects due to smoothly-truncated universal density profiles in cold dark matter model. For our isolated haloes the density profile falls off as radius to the minus fifth or seventh power beyond the tidal radius, functional forms that allow all orders of lens potential derivatives to be calculated analytically, while ensuring a non-divergent total mass. We show how the observables predicted by this profile differ from that of the original infinite-mass NFW profile. Expressions for the gravitational flexion are highlighted. We show how decreasing the tidal radius allows stripped haloes to be modeled, providing a framework for a fuller investigation of dark matter substructure in galaxies and clusters. Finally we remark on the need for finite mass halo profiles when doing cosmological ray-tracing simulations, and the need for readily-calculable higher order derivatives of the lens potential when studying catastrophes in strong lenses.

  10. Eye lens dose in interventional cardiology

    International Nuclear Information System (INIS)

    The ICRP has recently recommended reducing the occupational exposure dose limit for the lens of the eye to 20 mSv y-1 , averaged over a period of 5 y, with no year exceeding 50 mSv, instead of the current 150 mSv y-1 . This reduction will have important implications for interventional cardiology and radiology (IC/IR) personnel. In this work, lens dose received by a staff working in IC is studied in order to determine whether eye lens dose monitoring or/and additional radiological protection measures are required. Eye lens dose exposure was monitored in 10 physicians and 6 nurses. The major IC procedures performed were coronary angiography and percutaneous transluminal coronary angioplasty. The personnel were provided with two thermoluminescent dosemeters (TLDs): one calibrated in terms of Hp(3) located close to the left ear of the operator and a whole-body dosemeter calibrated in terms of Hp(10) and Hp(0.07) positioned on the lead apron. The estimated annual eye lens dose for physicians ranged between 8 and 60 mSv, for a workload of 200 procedures y-1. Lower doses were collected for nurses, with estimated annual Hp(3) between 2 and 4 mSv y-1. It was observed that for nurses the Hp(0.07) measurement on the lead apron is a good estimate of eye lens dose. This is not the case for physicians, where the influence of both the position and use of protective devices such as the ceiling shield is very important and produces large differences among doses both at the eyes and on the thorax. For physicians, a good correlation between Hp(3) and dose area product is shown. (authors)

  11. Roadmap-Based Level Clearing of Buildings

    KAUST Repository

    Rodriguez, Samuel

    2011-01-01

    In this paper we describe a roadmap-based approach for a multi-agent search strategy to clear a building or multi-story environment. This approach utilizes an encoding of the environment in the form of a graph (roadmap) that is used to encode feasible paths through the environment. The roadmap is partitioned into regions, e.g., one per level, and we design region-based search strategies to cover and clear the environment. We can provide certain guarantees within this roadmap-based framework on coverage and the number of agents needed. Our approach can handle complex and realistic environments where many approaches are restricted to simple 2D environments. © 2011 Springer-Verlag.

  12. Multiphoton microscopy of cleared mouse organs

    Science.gov (United States)

    Parra, Sonia G.; Chia, Thomas H.; Zinter, Joseph P.; Levene, Michael J.

    2010-05-01

    Typical imaging depths with multiphoton microscopy (MPM) are limited to less than 300 μm in many tissues due to light scattering. Optical clearing significantly reduces light scattering by replacing water in the organ tissue with a fluid having a similar index of refraction to that of proteins. We demonstrate MPM of intact, fixed, cleared mouse organs with penetration depths and fields of view in excess of 2 mm. MPM enables the creation of large 3-D data sets with flexibility in pixel format and ready access to intrinsic fluorescence and second-harmonic generation. We present high-resolution images and 3-D image stacks of the brain, small intestine, large intestine, kidney, lung, and testicle with image sizes as large as 4096×4096 pixels.

  13. Calculation of the transverse kicks generated by the bends of a hollow electron lens

    Energy Technology Data Exchange (ETDEWEB)

    Stancari, Giulio

    2014-03-25

    Electron lenses are pulsed, magnetically confined electron beams whose current-density profile is shaped to obtain the desired effect on the circulating beam in high-energy accelerators. They were used in the Fermilab Tevatron collider for abort-gap clearing, beam-beam compensation, and halo scraping. A beam-beam compensation scheme based upon electron lenses is currently being implemented in the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. This work is in support of a conceptual design of hollow electron beam scraper for the Large Hadron Collider. It also applies to the implementation of nonlinear integrable optics with electron lenses in the Integrable Optics Test Accelerator at Fermilab. We consider the axial asymmetries of the electron beam caused by the bends that are used to inject electrons into the interaction region and to extract them. A distribution of electron macroparticles is deposited on a discrete grid enclosed in a conducting pipe. The electrostatic potential and electric fields are calculated using numerical Poisson solvers. The kicks experienced by the circulating beam are estimated by integrating the electric fields over straight trajectories. These kicks are also provided in the form of interpolated analytical symplectic maps for numerical tracking simulations, which are needed to estimate the effects of the electron lens imperfections on proton lifetimes, emittance growth, and dynamic aperture. We outline a general procedure to calculate the magnitude of the transverse proton kicks, which can then be generalized, if needed, to include further refinements such as the space-charge evolution of the electron beam, magnetic fields generated by the electron current, and longitudinal proton dynamics.

  14. Internet compromise clears way for WSIS agreement

    CERN Multimedia

    Ermert, M

    2003-01-01

    A working group under the leadership of United Nations Secretary General Kofi Annan himself will try to resolve the deep differences on the question of Internet governance, officials said here. The group, whose exact membership wasn't immediately clear, is to propose a solution to the controversial issue that has given negotiators at the World Summit of the Information Society (WSIS) a headache (1/2 page).

  15. Rapid radiative clearing of protoplanetary discs

    CERN Document Server

    Haworth, Thomas J; Owen, James E

    2015-01-01

    The lack of observed transition discs with inner gas holes of radii greater than ~50AU implies that protoplanetary discs dispersed from the inside out must remove gas from the outer regions rapidly. We investigate the role of photoevaporation in the final clearing of gas from low mass discs with inner holes. In particular, we study the so-called "thermal sweeping" mechanism which results in rapid clearing of the disc. Thermal sweeping was originally thought to arise when the radial and vertical pressure scale lengths at the X-ray heated inner edge of the disc match. We demonstrate that this criterion is not fundamental. Rather, thermal sweeping occurs when the pressure maximum at the inner edge of the dust heated disc falls below the maximum possible pressure of X-ray heated gas (which depends on the local X-ray flux). We derive new critical peak volume and surface density estimates for rapid radiative clearing which, in general, result in rapid dispersal happening less readily than in previous estimates. Thi...

  16. Fabrication of an unusual mosaic lens

    International Nuclear Information System (INIS)

    The design philosophy and the construction techniques to make a novel mosaic lens to collect Cerenkow radiation are described. The lens blanks were rough cut into segments by a water jet. The segments were cut to the final inner and outer diameters by ultrasonically assisted machining, an unusual new technique developed at the Los Alamos National Laboratory. The technology will soon be available to the public through Sonic Mill, Inc., 3820 Academy Parkway North, NE, Albuquerque, N.M. 87109. The advantage of ultrasonically assisted machining lies in rapid, accurate shaping of brittle materials such as ceramics and glass, which can by this technique, be shaped about as fast as aluminum

  17. Time resolved thermal lens in edible oils

    Science.gov (United States)

    Albuquerque, T. A. S.; Pedreira, P. R. B.; Medina, A. N.; Pereira, J. R. D.; Bento, A. C.; Baesso, M. L.

    2003-01-01

    In this work time resolved thermal lens spectrometry is applied to investigate the optical properties of the following edible oils: soya, sunflower, canola, and corn oils. The experiments were performed at room temperature using the mode mismatched thermal lens configuration. The results showed that when the time resolved procedure is adopted the technique can be applied to investigate the photosensitivity of edible oils. Soya oil presented a stronger photochemical reaction as compared to the other investigated samples. This observation may be relevant for future studies evaluating edible oils storage conditions and also may contribute to a better understanding of the physical and chemical properties of this important foodstuff.

  18. Sterilization potential of contact lens solutions

    Directory of Open Access Journals (Sweden)

    Dada Vijay

    1988-01-01

    Full Text Available In a dynamic field of Contact Lens Solutions maintenance of high standards of anti-microbial activity is a must Resterilization Activity Time′ is a universally accepted yardstick for such an evaluation. In this study eight brands of indigenous popular solutions alongwith two FDA approved solutions were tested for their sterilization efficacy: Standardized suspensions of Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and Aspergillus fumigatus were used for the purpose. It was observed that the contact lens solutions available ir, the domestic market were not upto the mark Suggestions for improvement have also been made.

  19. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    Directory of Open Access Journals (Sweden)

    Elena Bonafonte Marquez

    2015-01-01

    Full Text Available We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for it could be the only sign of secondary glaucoma.

  20. Coherent diffraction imaging by moving a lens.

    Science.gov (United States)

    Shen, Cheng; Tan, Jiubin; Wei, Ce; Liu, Zhengjun

    2016-07-25

    A moveable lens is used for determining amplitude and phase on the object plane. The extended fractional Fourier transform is introduced to address the single lens imaging. We put forward a fast algorithm for the transform by convolution. Combined with parallel iterative phase retrieval algorithm, it is applied to reconstruct the complex amplitude of the object. Compared with inline holography, the implementation of our method is simple and easy. Without the oversampling operation, the computational load is less. Also the proposed method has a superiority of accuracy over the direct focusing measurement for the imaging of small size objects. PMID:27464107

  1. Rotman lens for mm-wavelengths

    Science.gov (United States)

    Hall, Leonard T.; Hansen, Hedley J.; Abbott, Derek

    2002-11-01

    The 77 GHz band has been reserved for intelligent cruise control in luxury cars and some public transport services in America and the United Kingdom. The Rotman lens offers a cheap and compact means to extend the single beam systems generally used, to fully functional beam staring arrangements. Rotman lenses have been built for microwave frequencies with limited success. The flexibility of microstrip transmission lines and the advent of fast accurate simulation packages allow practical Rotman lenses to be designed at mm-wavelengths. This paper discusses the limitations of the conventional design approach and predicts the performance of a new Rotman lens designed at 77 GHz.

  2. Pulse transformer for the AA lithium lens

    CERN Multimedia

    1980-01-01

    The antiprotons emanating from the target were initially focused by a magnetic horn. Later on, a Li-lens was used during operation for the SPS collider, until 1992. A Li-rod (130 mm long, 34 mm in diameter) constituted the secondary of a 1:23 pulse-transformer. The half-sine pulse rose to 1000 kA in 900 microsec. The angular acceptance was 95 mrad. In operation after 1992, for LEAR only, a more modest Li-lens was used (155 mm long, diameter 20 mm, 480 kA, risetime 240 microsec, angular acceptance 75 mrad).

  3. Herniation of the anterior lens capsule

    Directory of Open Access Journals (Sweden)

    Pereira Nolette

    2007-01-01

    Full Text Available Herniation of the anterior lens capsule is a rare abnormality in which the capsule bulges forward in the pupillary area. This herniation can be mistaken for an anterior lenticonus where both the capsule and the cortex bulge forward. The exact pathology behind this finding is still unclear. We report the clinical, ultrasound biomicroscopy (UBM and histopathological findings of a case of herniation of the anterior lens capsule. UBM helped to differentiate this entity from anterior lenticonus. Light microscopy revealed capsular splitting suggestive of capsular delamination and collection of fluid (aqueous in the area of herniation giving it a characteristic appearance.

  4. Auto-measurement system of aerial camera lens' resolution based on orthogonal linear CCD

    Science.gov (United States)

    Zhao, Yu-liang; Zhang, Yu-ye; Ding, Hong-yi

    2010-10-01

    The resolution of aerial camera lens is one of the most important camera's performance indexes. The measurement and calibration of resolution are important test items in in maintenance of camera. The traditional method that is observing resolution panel of collimator rely on human's eyes using microscope and doing some computing. The method is of low efficiency and susceptible to artificial factors. The measurement results are unstable, too. An auto-measurement system of aerial camera lens' resolution, which uses orthogonal linear CCD sensor as the detector to replace reading microscope, is introduced. The system can measure automatically and show result real-timely. In order to measure the smallest diameter of resolution panel which could be identified, two orthogonal linear CCD is laid on the imaging plane of measured lens and four intersection points are formed on the orthogonal linear CCD. A coordinate system is determined by origin point of the linear CCD. And a circle is determined by four intersection points. In order to obtain the circle's radius, firstly, the image of resolution panel is transformed to pulse width of electric signal which is send to computer through amplifying circuit and threshold comparator and counter. Secondly, the smallest circle would be extracted to do measurement. The circle extraction made using of wavelet transform which has character of localization in the domain of time and frequency and has capability of multi-scale analysis. Lastly, according to the solution formula of lens' resolution, we could obtain the resolution of measured lens. The measuring precision on practical measurement is analyzed, and the result indicated that the precision will be improved when using linear CCD instead of reading microscope. Moreover, the improvement of system error is determined by the pixel's size of CCD. With the technique of CCD developed, the pixel's size will smaller, the system error will be reduced greatly too. So the auto

  5. Experimental characterization of the Clear-PEM scanner spectrometric performance

    Science.gov (United States)

    Bugalho, R.; Carriço, B.; Ferreira, C. S.; Frade, M.; Ferreira, M.; Moura, R.; Ortigão, C.; Pinheiro, J. F.; Rodrigues, P.; Rolo, I.; Silva, J. C.; Trindade, A.; Varela, J.

    2009-10-01

    In the framework of the Clear-PEM project for the construction of a high-resolution and high-specificity scanner for breast cancer imaging, a Positron Emission Mammography tomograph has been developed and installed at the Instituto Português de Oncologia do Porto hospital. The Clear-PEM scanner is mainly composed by two planar detector heads attached to a robotic arm, trigger/data acquisition electronics system and computing servers. The detector heads hold crystal matrices built from 2 × 2 × 20 mm3 LYSO:Ce crystals readout by Hamamatsu S8550 APD arrays. The APDs are optically coupled to both ends of the 6144 crystals in order to extract the DOI information for each detected event. Each one of 12288 APD's pixels is read and controlled by Application Specific Integrated Circuits water-cooled by an external cooling unit. The Clear-PEM frontend boards innovative design results in a unprecedented integration of the crystal matrices, APDs and ASICs, making Clear-PEM the PET scanner with the highest number of APD pixels ever integrated so far. In this paper, the scanner's main technical characteristics, calibration strategies and the first spectrometric performance evaluation in a clinical environment are presented. The first commissioning results show 99.7% active channels, which, after calibration, have inter-pixel and absolute gain distributions with dispersions of, respectively, 12.2% and 15.3%, demonstrating that despite the large number of channels, the system is uniform. The mean energy resolution at 511 keV is of 15.9%, with a 8.8% dispersion, and the mean CDOI-1 is 5.9%/mm, with a 7.8% dispersion. The coincidence time resolution, at 511 keV, for a energy window between 400 and 600 keV, is 5.2 ns FWHM.

  6. Once-punctured tori and knots in lens spaces

    OpenAIRE

    Baker, Kenneth L.

    2006-01-01

    We determine the non-null homologous knots in lens spaces whose exteriors contain properly embedded once-punctured tori. All such knots arise as surgeries on the Whitehead link and are grid number 1 in their lens spaces. As a corollary, we classify once-punctured torus bundles that admit a lens space filling.

  7. 21 CFR 886.1425 - Lens measuring instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lens measuring instrument. 886.1425 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1425 Lens measuring instrument. (a) Identification. A lens measuring instrument is an AC-powered device intended to measure the power of...

  8. 21 CFR 886.1405 - Ophthalmic trial lens set.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens set. 886.1405 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1405 Ophthalmic trial lens set. (a) Identification. An ophthalmic trial lens set is a device that is a set of lenses of various dioptric...

  9. 21 CFR 886.4300 - Intraocular lens guide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens guide. 886.4300 Section 886.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device...

  10. 21 CFR 886.1420 - Ophthalmic lens gauge.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic lens gauge. 886.1420 Section 886.1420...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1420 Ophthalmic lens gauge. (a) Identification. An ophthalmic lens gauge is a calibrated device intended to manually measure the curvature of...

  11. 21 CFR 886.1410 - Ophthalmic trial lens clip.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens clip. 886.1410 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1410 Ophthalmic trial lens clip. (a) Identification. An ophthalmic trial lens clip is a device intended to hold prisms, spheres, cylinders,...

  12. Nitrous oxide flux following tropical land clearing

    Science.gov (United States)

    Luizao, Flavio; Luizao, Regina; Matson, Pamela; Livingston, Gerald; Vitousek, Peter

    1989-01-01

    The importance of seasonal cycles of N2O flux from tropical ecosystems and the possibility that tropical deforestation could contribute to the ongoing global increase in N2O concentrations were assessed by measuring N2O flux from forest, cleared land, and pasture over an annual cycle in the central Amazon. A pasture that had been converted from tropical forest had threefold greater annual N2O flux than a paired forest site; similar results were obtained in spot measurements in other pastures. If these results are general, such tropical pastures represent a globally significant source of increased N2O.

  13. CHINA'S WORST OIL LEAK CLEARED EXPENSIVELY

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    @@ Eight days and nights of clean-up efforts after the worst oil leak ever in Chinese waters, the aftermath of a collision between two foreign ships happening at 9:35 pm on December 7 about 8 nautical miles away from the mouth of the Pearl River and near the Danjiang Island, have finally paid off. So far, hundreds of tons of waste oil and polluted water have been cleared up. A large area of oil spills has been cleaned thanks to the prompt and proper operation launched just two hours after the accident.

  14. Greenhouse problem in the Amazon jungle clearing

    International Nuclear Information System (INIS)

    This paper discusses the contribution of Amazon jungle clearing to the greenhouse problem and makes an assessment of long-run prospects. The introductory sections pose the problem from both international and Brazilian perspectives. The next section describes major features of the Amazonia ecosystems and presents methods and evidence on deforestation and on its impact on carbon dioxide emissions. Based upon cross-section information for a sample of municipalities in the Brazilian Amazon, the following section estimates elasticities of deforestation in relation to major economic factors- government policies included- and uses them to make projections for the future pace of deforestation. The last section discusses policy alternatives to slow down forest conversion

  15. PLANETARY CHAOTIC ZONE CLEARING: DESTINATIONS AND TIMESCALES

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Sarah; Malhotra, Renu [Lunar and Planetary Laboratory, The University of Arizona, Tucson, AZ 85721 (United States)

    2015-01-20

    We investigate the orbital evolution of particles in a planet's chaotic zone to determine their final destinations and their timescales of clearing. There are four possible final states of chaotic particles: collision with the planet, collision with the star, escape, or bounded but non-collision orbits. In our investigations, within the framework of the planar circular restricted three body problem for planet-star mass ratio μ in the range 10{sup –9} to 10{sup –1.5}, we find no particles hitting the star. The relative frequencies of escape and collision with the planet are not scale-free, as they depend upon the size of the planet. For planet radius R{sub p} ≥ 0.001 R{sub H} where R{sub H} is the planet's Hill radius, we find that most chaotic zone particles collide with the planet for μ ≲ 10{sup –5}; particle scattering to large distances is significant only for higher mass planets. For fixed ratio R{sub p} /R{sub H} , the particle clearing timescale, T {sub cl}, has a broken power-law dependence on μ. A shallower power law, T {sub cl} ∼ μ{sup –1/3}, prevails at small μ where particles are cleared primarily by collisions with the planet; a steeper power law, T {sub cl} ∼ μ{sup –3/2}, prevails at larger μ where scattering dominates the particle loss. In the limit of vanishing planet radius, we find T {sub cl} ≈ 0.024 μ{sup –3/2}. The interior and exterior boundaries of the annular zone in which chaotic particles are cleared are increasingly asymmetric about the planet's orbit for larger planet masses; the inner boundary coincides well with the classical first order resonance overlap zone, Δa {sub cl,} {sub int} ≅ 1.2 μ{sup 0.28} a{sub p} ; the outer boundary is better described by Δa {sub cl,} {sub ext} ≅ 1.7 μ{sup 0.31} a{sub p} , where a{sub p} is the planet-star separation.

  16. A gap clearing kicker for Main Injector

    CERN Document Server

    Kourbanis, I; Biggs, J; Brown, B; Capista, D; Jensen, C C; Krafczyk, G E; Morris, D K; Scott, D; Seiya, K; Ward, S R; Wu, G; Yang, M -J

    2012-01-01

    Fermilab Main Injector has been operating at high Beam Power levels since 2008 when multi-batch slip stacking became operational. In order to maintain and increase the beam power levels the localized beam loss due to beam left over in the injection kicker gap during slip stacking needs to be addressed. A set of gap clearing kickers that kick any beam left in the injection gap to the beam abort have been built. The kickers were installed in the summer of 2009 and became operational in November of 2010. The kicker performance and its effect on the beam losses will be described.

  17. Stem cell and lens regeneration%干细胞与晶状体再生

    Institute of Scientific and Technical Information of China (English)

    刘奕志; 董夏

    2014-01-01

    Cataract extraction and intraocular implantation surgery is the most effective treatment for cataract. However, as a kind of replacement material, artificial lens has some unavoidable defects, including the poor refractive accommodation power and the postoperative glare. Requirement for more ideal lens alternatives and the strong lens regeneration ability of lower amphibians (such as newt) motive the research of lens regeneration. In recent years, lentoid bodies have been regenerated from embryonic stem cells and induced pluripotent stem cells. The studies of lens regeneration will lay the foundation for the understanding of normal lens development and the pathogenesis and treatment of lens diseases. The success of lens regeneration will bring a landmark breakthrough for the treatment of cataract. This review describes the research progresses in the regulatory factors of lens during normal development, and introduce the possibility of the lens regeneration, and then summarize the progresses in the regenerated lens derived from embryonic stem cells, induced pluripotent stem cells and lens progenitor cells.%白内障摘除联合人工晶状体植入术是目前治疗白内障的唯一有效措施。然而,人工晶状体作为替代材料,仍然存在一些如屈光调节力差以及术后眩光等未能克服的缺陷。寻找更理想的晶状体替代物及低等两栖类动物(如蝾螈)强大的晶状体再生能力,为晶状体再生的研究提供了原动力和依据。近年来,人们已探索出将胚胎干细胞/诱导的多能干细胞在体外诱导分化为类晶状体样结构的培养方法,为白内障的治疗开辟了新的思路。晶状体再生的研究为探索晶状体正常发育机制及晶状体疾病的发生和防治提供了新的平台。晶状体再生的成功也将为白内障的防治带来里程碑性的突破。本文拟总结晶状体正常发育过程及其调控机制,回顾国内外对晶状体体内再生能

  18. Design considerations for millimetre wave lens antennas

    Science.gov (United States)

    Dewey, R. J.

    1982-12-01

    Attention is given to the operational background and some of the possible single and dual lens antenna options for use in a millimetric sensor with a beamwidth of approximately 3 deg. A particular single lens antenna design is found to give a scan of more than + or - 3 beamwidths and to be compatible with conical scan, beam broadening, and monopulse operation. A dual lens antenna design is operated both with a single feed horn and with a rectangular matrix of plain waveguide radiators (with potential application in real-time imaging). Good scan characteristics are obtained out to + or - 6 beam-widths with the single feed horn, although it is found that the matrix feed assembly needs a group of elements to be fed in phase before equivalent performance can be obtained. The goal of the study presented here is to simulate feeding the lens antenna with a monolithic array, and whereas an array of waveguides cannot accurately model all the properties of a monolithic array, they are considered sufficiently representative to indicate some of the compromises that may have to be made.

  19. Liquid-filled tunable lenticular lens

    Science.gov (United States)

    Iimura, Yoshinobu; Onoe, Hiroaki; Teshima, Tetsuhiko; Heo, Yun Jung; Yoshida, Shotaro; Morimoto, Yuya; Takeuchi, Shoji

    2015-03-01

    This paper describes a liquid-filled tunable lenticular lens for switching between two-dimensional (2D) and three-dimensional (3D) images in naked-eye 3D displays. Compared with previous 2D/3D switchable displays, this tunable lenticular lens that is directly attached to a smartphone display can project both a 2D image with the original resolution of the smartphone display and a 3D image with high brightness. This lens is simply composed of transparent poly(dimethylsiloxane) (PDMS) microchannels. While the thin top membrane on the microchannels is normally flat to transmit light without deflection for displaying 2D images, applying pressure to the microchannel deforms the membrane to acquire characteristics of lenticular lenses for 3D images. We successfully demonstrate the switching between the 2D and 3D modes. We believe that our lens can be applied as a part of a portable 2D/3D naked-eye 3D display.

  20. Testing and inspecting lens by holographic means

    Science.gov (United States)

    Hildebrand, Bernard P.

    1976-01-01

    Processes for the accurate, rapid and inexpensive testing and inspecting of oncave and convex lens surfaces through holographic means requiring no beamsplitters, mirrors or overpower optics, and wherein a hologram formed in accordance with one aspect of the invention contains the entire interferometer and serves as both a master and illuminating source for both concave and said convex surfaces to be so tested.

  1. Lens testing using total internal reflection holography

    Science.gov (United States)

    Hildebrand, Bernard P.

    1976-12-14

    Accurate, rapid and inexpensive testing and inspecting of lens surfaces tugh holographic means requiring no beamsplitters, mirrors or overpower optics, and wherein a hologram formed in accordance with one aspect of the invention contains the entire interferometer and serves as both a master and illuminating source for both concave and convex surfaces to be so tested.

  2. Disruptive advancement in precision lens mounting

    Science.gov (United States)

    Lamontagne, Frédéric; Desnoyers, Nichola; Doucet, Michel; Côté, Patrice; Gauvin, Jonny; Anctil, Geneviève

    2015-09-01

    Threaded rings are used to fix lenses in a large portion of opto-mechanical assemblies. This is the case for the low cost drop-in approach in which the lenses are dropped into cavities cut into a barrel and clamped with threaded rings. The walls of a cavity are generally used to constrain the lateral and axial position of the lens within the cavity. In general, the drop-in approach is low cost but imposes fundamental limitations especially on the optical performances. On the other hand, active alignment methods provide a high level of centering accuracy but increase the cost of the optical assembly. This paper first presents a review of the most common lens mounting techniques used to secure and center lenses in optical systems. Advantages and disadvantages of each mounting technique are discussed in terms of precision and cost. Then, the different contributors which affect the centering of a lens when using the drop-in approach, such as the threaded ring, friction, and manufacturing errors, are detailed. Finally, a patent pending lens mounting technique developed at INO that alleviates the drawbacks of the drop-in and the active alignment approaches is introduced. This innovative auto-centering method requires a very low assembly time, does not need tight manufacturing tolerances and offers a very high level of centering accuracy, usually less than 5 μm. Centering test results performed on real optical assemblies are also presented.

  3. Galaxy mergers and gravitational lens statistics

    Science.gov (United States)

    Rix, Hans-Walter; Maoz, Dan; Turner, Edwin L.; Fukugita, Masataka

    1994-01-01

    We investigate the impact of hierarchical galaxy merging on the statistics of gravitational lensing of distant sources. Since no definite theoretical predictions for the merging history of luminous galaxies exist, we adopt a parameterized prescription, which allows us to adjust the expected number of pieces comprising a typical present galaxy at z approximately 0.65. The existence of global parameter relations for elliptical galaxies and constraints on the evolution of the phase space density in dissipationless mergers, allow us to limit the possible evolution of galaxy lens properties under merging. We draw two lessons from implementing this lens evolution into statistical lens calculations: (1) The total optical depth to multiple imaging (e.g., of quasars) is quite insensitive to merging. (2) Merging leads to a smaller mean separation of observed multiple images. Because merging does not reduce drastically the expected lensing frequency, it cannot make lambda-dominated cosmologies compatible with the existing lensing observations. A comparison with the data from the Hubble Space Telescope (HST) Snapshot Survey shows that models with little or no evolution of the lens population are statistically favored over strong merging scenarios. A specific merging scenario proposed to Toomre can be rejected (95% level) by such a comparison. Some versions of the scenario proposed by Broadhurst, Ellis, & Glazebrook are statistically acceptable.

  4. Changes in "thermal lens" measure diffusivity

    Science.gov (United States)

    Gupta, A.; Hong, S. D.; Moacanin, J.

    1980-01-01

    In an extension of "thermal lens" effect to new applications and better resolution, two laser beams combine to rapidly measure thermal diffusivity and other molecular dynamic properties. New double-beam technique handles very small samples unlike classical techniques for measuring diffusivity. It can be used for measurements on samples undergoing stress, making it applicable to data collection for structural engineering.

  5. Contact Lens-Related Eye Infections

    Science.gov (United States)

    ... may lead to the need for a cornea transplant . Learn more about keratitis: Bacterial keratitis Fungal keratitis Herpes keratitis Symptoms of contact lens-related infections may include blurry vision, unusual redness of the eye, pain in the eye, tearing or discharge from ...

  6. SHARP - III: First Use Of Adaptive Optics Imaging To Constrain Cosmology With Gravitational Lens Time Delays

    CERN Document Server

    Chen, Geoff C F; Wong, Kenneth C; Fassnacht, Christopher D; Chiueh, Tzihong; Halkola, Aleksi; Hu, I Shing; Auger, Matthew W; Koopmans, Leon V E; Lagattuta, David J; McKean, John P; Vegetti, Simona

    2016-01-01

    Accurate and precise measurements of the Hubble constant are critical for testing our current standard cosmological model and revealing possibly new physics. With Hubble Space Telescope (HST) imaging, each strong gravitational lens system with measured time delays can allow one to determine the Hubble constant with an uncertainty of $\\sim 7\\%$. Since HST will not last forever, we explore adaptive-optics (AO) imaging as an alternative that can provide higher angular resolution than HST imaging but has a less stable point spread function (PSF) due to atmospheric distortion. To make AO imaging useful for time-delay-lens cosmography, we develop a method to extract the unknown PSF directly from the imaging of strongly lensed quasars. In a blind test with two mock data sets created with different PSFs, we are able to recover the important cosmological parameters (time-delay distance, external shear, lens mass profile slope, and total Einstein radius). Our analysis of the Keck AO image of the strong lens system RXJ1...

  7. Oxidation of Lipids and Proteins in Lens and Blood Plasma of Rats in Ageing

    Directory of Open Access Journals (Sweden)

    Ivanova I.P.

    2011-09-01

    Full Text Available The aim of the study is to assess the intensity of oxidation of lipids and proteins in lens and blood plasma of Wistar rats in ageing. Materials and Methods. The experiments were carried out on 25 Wistar male rats of four age groups: 5, 12, 24 and 36 months. Materials for study were lens and blood plasma. Lipids were extracted using Folch partition. The content of diene and triene conjugates was assessed by means of spectrophotometry. The level of Schiff’s bases was studied according to fluorescence intensity, malon dialdehyde concentration — according to the intensity of interaction with thiobarbituric acid. Potentiality of substrate oxidation in specimen was assessed using the method of induced chemoluminescence, and the degree of protein oxidative modification was assessed according to the level of carbonyl derivatives with 2.4-dinitrophenylhydrasine. The investigation of the content of total lipids and total proteins were carried out using “Bio-Test Total Lipids” and “Total Protein-Vital”. Results. The processes of lipid peroxidation of lens membranes are increasing in animals aged 5—12 months and decreasing in the period of 12—24 months. The level of lipid peroxidation in blood plasma has an expressed tendency for increasing in ageing. Over the years, there is the level decrease of carbonyl derivatives of aminoacids of lens proteins and the tendency for the increase of oxidative modification of proteins in blood plasma.

  8. High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients

    OpenAIRE

    Tomris Sengor; Sevda Aydin Kurna; Suat Aki; et al

    2011-01-01

    Tomris Sengor, Sevda Aydin Kurna, Suat Aki, Yelda ÖzkurtFatih Sultan Mehmet Training and Research Hospital, Istanbul, TurkeyBackground: The aim of the study was to examine the clinical success of high Dk (oxygen permeability) piggyback contact lens (PBCL) systems for the correction of contact lens intolerant keratoconus patients.Methods: Sixteen patients (29 eyes) who were not able to wear gas-permeable rigid lenses were included in this study. Hyper Dk silicone hydrogel (oxygen tran...

  9. The influence of lens material and lens wear on the removal and viability of staphylococcus epidermidis

    OpenAIRE

    Santos, Lívia; Rodrigues, Diana Alexandra Ferreira; Lira, Madalena; Oliveira, M. Elisabete; Oliveira, Rosário; Yebra-Pimentel Vilar, Eva; Azeredo, Joana

    2008-01-01

    Purpose: The aim of this study was to evaluate the influence of lens material and lens wear on the removal capability of Staphylococcus epidermidis. Assessment of viability of remaining adhered bacteria was another goal of this work. Four silicone hydrogel materials (galyfilcon A, balafilcon A, lotrafilcon A, lotrafilcon B) and one conventional hydrogel material (etafilcon A) were assayed. Methods: Detachment studies on S. epidermidis were carried out in a parallel plate flow chamber...

  10. Preventive role of lens antioxidant defense mechanism against riboflavin-mediated sunlight damaging of lens crystallins.

    Science.gov (United States)

    Anbaraki, Afrooz; Khoshaman, Kazem; Ghasemi, Younes; Yousefi, Reza

    2016-10-01

    The main components of sunlight reaching the eye lens are UVA and visible light exerting their photo-damaging effects indirectly by the aid of endogenous photosensitizer molecules such as riboflavin (RF). In this study, lens proteins solutions were incubated with RF and exposed to the sunlight. Then, gel mobility shift analysis and different spectroscopic assessments were applied to examine the structural damaging effects of solar radiation on these proteins. Exposure of lens proteins to direct sunlight, in the presence of RF, leads to marked structural crosslinking, oligomerization and proteolytic instability. These structural damages were also accompanied with reduction in the emission fluorescence of Trp and Tyr and appearance of a new absorption peak between 300 and 400nm which can be related to formation of new chromophores. Also, photo-oxidation of lens crystallins increases their oligomeric size distribution as examined by dynamic light scattering analysis. The above mentioned structural insults, as potential sources of sunlight-induced senile cataract and blindness, were significantly attenuated in the presence of ascorbic acid and glutathione which are two important components of lens antioxidant defense system. Therefore, the powerful antioxidant defense mechanism of eye lens is an important barrier against molecular photo-damaging effects of solar radiations during the life span. PMID:27316765

  11. Multi-actuator adaptive lens for wavefront correction in optical coherence tomography and two-photon excitation fluorescence microscopy (Conference Presentation)

    Science.gov (United States)

    Bonora, Stefano; Lee, Sujin; Jian, Yifan; Cua, Michelle; Pugh, Edward N.; Zawadzki, Robert J.; Sarunic, Marinko V.

    2016-03-01

    We present a new type of adaptive lens with 18 actuators that can correct up the 4th order of aberration. The Multi-actuator Adaptive Lens (M-AL) can guarantee a good level of aberration correction for many applications and, with respect to deformable mirror, it allows the realization of more compact and simple optical systems. The adaptive lens is based on the use of piezoelectric actuators and, without any obstruction or electrodes in the clear aperture, can guarantee a fast response time, in the order of about 10ms. The clear aperture of the M-AL allows its use in "classical" Adaptive Optics configuration together with a wavefront sensor. To introduce a further simplification to the optical system design we show that the adaptive lens can be also driven with a wavefront sensorless control algorithm during in vivo optical coherence tomography of the human retina and for two-photon excitation fluorescence microscopy. In the experimental setup we used two aberration correcting devices a commercial adaptive lens (AL) with a high dynamic range to correct for defocus and the Multi-actuator Adaptive Lens (M-AL) to correct for the Zernike aberrations up to the 4th order. Experimental results show that the ocular aberrations of human eyes can be successfully corrected with our M-AL for pupils of 5mm and that retinal cones can be readily imaged.

  12. Gram negative bacteria and contact lens induced acute red eye

    Directory of Open Access Journals (Sweden)

    Sankaridurg Padmaja

    1996-01-01

    Full Text Available Two patients using hydrogel contact lenses on a daily wear schedule slept overnight with the lenses and woke up with a Contact Lens Induced Acute Red Eye (CLARE. The contact lenses recovered aseptically at the time of the event grew significant colonies of Pseudomonas aeruginosa and Aeromonas hydrophila in patient A and Pseudomonas aeruginosa and Serratia liquefaciens from patient B. Similar organisams from the contact lenses were recovered from the lens case and lens care solutions of patient B. In both the patients the condition resolved on discontinuation of lens wear. Patient compliance as a requirement for successful contact lens wear is highlighted with the illustration of these cases.

  13. An unusual case of clear cell meningioma

    Directory of Open Access Journals (Sweden)

    Deb Prabal

    2009-01-01

    Full Text Available Clear-cell meningioma (CCM is an uncommon, aggressive variant of meningioma, usually affecting younger females and having predilection for infratentorial locations. We present a rare case of recurrent supratentorial CCM in a 58-year-old male. Ten years back, he had an intra-axial tumor in the left occipital lobe, which was managed by surgical excision and radiotherapy. Currently, the patient presented with sudden severe headache along with speech and vision disturbances. Neuroimaging revealed an extra-axial parietooccipital tumor, with intratumoural bleed. Histopathology of both tumors showed features of CCM, immunopositive for epithelial membrane antigen (EMA and vimentin. This case illustrates multiple unusual features of a rare variant of meningioma in the form of affection of an adult age group, supratentorial location, recurrence, and intratumoral bleed. It also highlights the importance of incorporating immunohistochemistry in the diagnostic workup, to exclude CCM mimics, each having distinctive biological behavior, and prognostic outcome, and warranting different therapeutic protocols.

  14. Acid phosphatase and lipid peroxidation in human cataractous lens epithelium

    Directory of Open Access Journals (Sweden)

    Vasavada Abhay

    1993-01-01

    Full Text Available The anterior lens epithelial cells undergo a variety of degenerative and proliferative changes during cataract formation. Acid phosphatase is primarily responsible for tissue regeneration and tissue repair. The lipid hydroperoxides that are obtained by lipid peroxidation of polysaturated or unsaturated fatty acids bring about deterioration of biological membranes at cellular and tissue levels. Acid phosphatase and lipid peroxidation activities were studied on the lens epithelial cells of nuclear cataract, posterior subcapsular cataract, mature cataract, and mixed cataract. Of these, mature cataractous lens epithelium showed maximum activity for acid phosphatase (516.83 moles of p-nitrophenol released/g lens epithelium and maximum levels of lipid peroxidation (86.29 O.D./min/g lens epithelium. In contrast, mixed cataractous lens epithelium showed minimum activity of acid phosphatase (222.61 moles of p-nitrophenol released/g lens epithelium and minimum levels of lipid peroxidation (54.23 O.D./min/g lens epithelium. From our study, we correlated the maximum activity of acid phosphatase in mature cataractous lens epithelium with the increased areas of superimposed cells associated with the formation of mature cataract. Likewise, the maximum levels of lipid peroxidation in mature cataractous lens epithelium was correlated with increased permeability of the plasma membrane. Conversely, the minimum levels of lipid peroxidation in mixed cataractous lens epithelium makes us presume that factors other than lipid peroxidation may also account for the formation of mixed type of cataract.

  15. Oxygen transport through soft contact lens and cornea: Lens characterization and metabolic modeling

    Science.gov (United States)

    Chhabra, Mahendra

    The human cornea requires oxygen to sustain metabolic processes critical for its normal functioning. Any restriction to corneal oxygen supply from the external environment (e.g., by wearing a low oxygen-permeability contact lens) can lead to hypoxia, which may cause corneal edema (swelling), limbal hyperemia, neovascularization, and corneal acidosis. The need for adequate oxygen to the cornea is a major driving force for research and development of hypertransmissible soft contact lenses (SCLs). Currently, there is no standard technique for measuring oxygen permeability (Dk) of hypertransmissible silicone-hydrogel SCLs. In this work, an electrochemistry-based polarographic apparatus was designed, built, and operated to measure oxygen permeability in hypertransmissible SCLs. Unlike conventional methods where a range of lens thickness is needed for determining oxygen permeabilities of SCLs, this apparatus requires only a single lens thickness. The single-lens permeameter provides a reliable, efficient, and economic tool for measuring oxygen permeabilities of commercial hypertransmissible SCLs. The single-lens permeameter measures not only the product Dk, but, following modification, it measures separately diffusivity, D, and solubility, k, of oxygen in hypertransmissible SCLs. These properties are critical for designing better lens materials that ensure sufficient oxygen supply to the cornea. Metabolism of oxygen in the cornea is influenced by contact-lens-induced hypoxia, diseases such as diabetes, surgery, and drug treatment, Thus, estimation of the in-vivo corneal oxygen consumption rate is essential for gauging adequate oxygen supply to the cornea. Therefore, we have developed an unsteady-state reactive-diffusion model for the cornea-contact-lens system to determine in-vivo human corneal oxygen-consumption rate. Finally, a metabolic model was developed to determine the relation between contact-lens oxygen transmissibility (Dk/L) and corneal oxygen deficiency. A

  16. Hypoplastic basement membrane of the lens anlage in the inheritable lens aplastic mouse (lap mouse).

    Science.gov (United States)

    Aso, S; Baba, R; Noda, S; Ikuno, S; Fujita, M

    2000-04-01

    Adult homozygous lap mice show various eye abnormalities such as aphakia, retinal disorganization, and dysplasia of the cornea and anterior chamber. In the fetal eye of a homozygous lap mouse, the lens placode appears to develop normally. However, the lens vesicle develops abnormally to form a mass of cells without a cavity, and the mass vanishes soon afterward. Apoptotic cell death is associated with the disappearance of the lens anlage. We examined the basement membranes of the lens anlage of this mutant by immunohistochemical methods under light microscopy using antibodies against basement membrane components of the lens anlage, type IV collagen, fibronectin, laminin, heparan sulfate proteoglycan, and entactin and by transmission electron microscopy. Immunohistochemistry showed the distribution and intensity of antibody binding to the lens anlage to be almost the same for each these antibodies regardless of the stage of gestation or whether the anlagen were from normal BALB/c or lap mice. Thus, positive continuous reactions were observed around the exterior region of the lens anlage from day 10 of gestation for type IV collagen, fibronectin, laminin, heparan sulfate proteoglycan antibodies, and at least from day 11of gestation for entactin antibody. The basement membrane lamina densa of both normal and lap mice was shown by electron microscopy to be discontinuous at days 10 and 10.5 of gestation. However, by day 11 the lamina densa was continuous in the lens anlagen of normal mice but still discontinuous in the lap mice. By day 12 of gestation, the lamina densa had thickened markedly in normal mice, whereas in lap mice it remained discontinuous and its thinness indicated hypoplasia. These results indicate that, while all basement components examined are produced and deposited in the normal region of the lens anlage in the lap mouse, the basement membrane is, for some reason, imperfectly formed. The time at which hypoplasia of the basement membrane was observed

  17. Method and apparatus for sputtering with a plasma lens

    Energy Technology Data Exchange (ETDEWEB)

    Anders, Andre

    2016-09-27

    A plasma lens for enhancing the quality and rate of sputter deposition onto a substrate is described herein. The plasma lens serves to focus positively charged ions onto the substrate while deflecting negatively charged ions, while at the same time due to the line of sight positioning of the lens, allowing for free passage of neutrals from the target to the substrate. The lens itself is formed of a wound coil of multiple turns, inside of which are deposed spaced lens electrodes which are electrically paired to impress an E field overtop the B field generated by the coil, the potential applied to the electrodes increasing from end to end towards the center of the lens, where the applied voltage is set to a high potential at the center electrodes as to produce a potential minimum on the axis of the lens.

  18. Ultrashort-Pulse Lasers Treating the Crystalline Lens: Will They Cause Vision-Threatening Cataract? (An American Ophthalmological Society Thesis)

    Science.gov (United States)

    Krueger, Ronald R.; Uy, Harvey; McDonald, Jared; Edwards, Keith

    2012-01-01

    Purpose: To demonstrate that ultrashort-pulse laser treatment in the crystalline lens does not form a focal, progressive, or vision-threatening cataract. Methods: An Nd:vanadate picosecond laser (10 ps) with prototype delivery system was used. Primates: 11 rhesus monkey eyes were prospectively treated at the University of Wisconsin (energy 25–45 μJ/pulse and 2.0–11.3M pulses per lens). Analysis of lens clarity and fundus imaging was assessed postoperatively for up to 4½ years (5 eyes). Humans: 80 presbyopic patients were prospectively treated in one eye at the Asian Eye Institute in the Philippines (energy 10 μJ/pulse and 0.45–1.45M pulses per lens). Analysis of lens clarity, best-corrected visual acuity, and subjective symptoms was performed at 1 month, prior to elective lens extraction. Results: Bubbles were immediately seen, with resolution within the first 24 to 48 hours. Afterwards, the laser pattern could be seen with faint, noncoalescing, pinpoint micro-opacities in both primate and human eyes. In primates, long-term follow-up at 4½ years showed no focal or progressive cataract, except in 2 eyes with preexisting cataract. In humans, 70% reported acceptable or better distance vision and no or mild symptoms. Meanwhile, >70% without sparing (0 and 0.5 mm radius) lost 2 or more lines, and most reported poor or severe vision and symptoms. Conclusions: Focal, progressive, and vision-threatening cataracts can be avoided by lowering the laser energy, avoiding prior cataract, and sparing the center of the lens. PMID:23818739

  19. Hyaluronic acid production and hyaluronidase activity in the newt iris during lens regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Kulyk, W.M.; Zalik, S.E.; Dimitrov, E.

    1987-09-01

    The process of lens regeneration in newts involves the dedifferentiation of pigmented iris epithelial cells and their subsequent conversion into lens fibers. In vivo this cell-type conversion is restricted to the dorsal region of the iris. We have examined the patterns of hyaluronate accumulation and endogenous hyaluronidase activity in the newt iris during the course of lens regeneration in vivo. Accumulation of newly synthesized hyaluronate was estimated from the uptake of (/sup 3/H)glucosamine into cetylpyridinium chloride-precipitable material that was sensitive to Streptomyces hyaluronidase. Endogenous hyaluronidase activity was determined from the quantity of reducing N-acetylhexosamine released upon incubation of iris tissue extract with exogenous hyaluronate substrate. We found that incorporation of label into hyaluronate was consistently higher in the regeneration-activated irises of lentectomized eyes than in control irises from sham-operated eyes. Hyaluronate labeling was higher in the dorsal (lens-forming) region of the iris than in ventral (non-lens-forming) iris tissue during the regeneration process. Label accumulation into hyaluronate was maximum between 10 and 15 days after lentectomy, the period of most pronounced dedifferentiation in the dorsal iris epithelium. Both normal and regenerating irises demonstrated a high level of endogenous hyaluronidase activity with a pH optimum of 3.5-4.0. Hyaluronidase activity was 1.7 to 2 times higher in dorsal iris tissue than in ventral irises both prior to lentectomy and throughout the regeneration process. We suggest that enhanced hyaluronate accumulation may facilitate the dedifferentiation of iris epithelial cells in the dorsal iris and prevent precocious withdrawal from the cell cycle. The high level of hyaluronidase activity in the dorsal iris may promote the turnover and remodeling of extracellular matrix components required for cell-type conversion.

  20. Nuclear threat. A clear and present danger

    International Nuclear Information System (INIS)

    It was disappointed at the discussion in the review conference of the NPT held in 2005. The fact may be caused by the estrangement between the international urgent issues related to the non-proliferation and the effectiveness of archaic measures through the NPT. However, it should not be recognized that the international obligation and worth of NPT has been gone. The NPT referred the typical international situation under the cold war era. Although several permanent issues of the nuclear non-proliferation exist in current discussions, the activities relevant to the NPT may not be effect against newly unstable situations after the September 11th of 2001. Urgent challenges to be taken are that we must strictly analyze the interventions between 'the clear and present danger' of our world and the nuclear herms, and must take appropriate actions toward them without influences from previous international situations that might be subsisted in current international treaties and agreements. This paper identified the features of nuclear threats based on the four categories and examined the possibilities of nuclear terrorism from previous facts with the inductive inference. The results identified the possibility of nuclear facility attack and of radioactive materials theft by the Polico-Religious Groups and others are stood out. The authors would suggest the important of urgent recognition to establish the certain security system against nuclear terrorism. (author)

  1. Experimental study on cyclosporine A drug delivery system in prevention of posterior capsule opacification after intraocular lens implantation in rabbits

    Institute of Scientific and Technical Information of China (English)

    Pei Cheng; Sun Naixue

    2008-01-01

    Objective To study the effect of cyclosporine A drug delivery system (CsA-DDS) on the prevention of posterior capsule opacification (PCO) after experimental intraocular lens implantation in rabbit eyes. Methods Twenty healthy New Zealand white rabbits, whose left eyes and right eyes were used respectively as experiment eyes and controls, were subjected to extracapsular lens extraction and artificial lens implantation. During the operation, CsA-DDS with poly (lactideco-glycolide) as carriers or empty DDS was implanted in the capsular bag for the experimental eyes and controls respectively. After the operation, anterior chamber reaction, intraocular pressure (IOP) and CsA concentration were monitored and twelve weeks after the operation, the eyes were extracted for histopathological and morphological examinations. Results There were no differences between the two groups in conjunctival congestion,IOP change and anterior chamber reaction. PCO was less severe in the experimental eyes than in the controls. Light microscopy revealed that posterior capsular membrane in the experimental eyes was slick, with no obvious proliferation,whereas in the controls, there were lens epithelial cell proliferation and cortex regeneration of different degrees.Morphological examination with electron microscope showed that in the experimental eyes, lens epithelial cells did not function actively and apoptosis occurred, whereas in the controls, epithelial cells presented active function. No marked ultrastructural changes were found in either group. Conclusion Cs-DDS can inhibit PCO after intraocular lens implantation in rabbit eyes and does not have toxic effects on the surrounding ocular tissues. Therefore, it has a good potential for clinical use in prevention of PCO.

  2. A polycarbonate ophthalmic-prescription lens series.

    Science.gov (United States)

    Davis, J K

    1978-08-01

    Improvements in polycarbonate material, production techniques, and scratch-resistant coatings, combined with a process-oriented design, have resulted in a precision lens series. Surface quality is comparable to that of untreated glass ophthalmic lenses. The repeatability of the process results in closely controlled axial power and off-axis performance. For most lens prescriptions, the ANSI Z80.1 optical-center specifications for prescription accuracy are maintained through a total field of view of 40 deg for an 8-mm range of center-of-rotation distances. Off-axis astigmatism is controlled for near-point seeing. The lenses are both lighter and thinner than those of crown glass. A scratch-resistant coating reduces the reflections normally associated with high-index (1.586) materials. Impact resistance exceeds that required by ANSI Z80.7 and is many times that required by ANSI Z80.1.

  3. Understanding Science Through the Computational Lens

    Institute of Scientific and Technical Information of China (English)

    Richard M. Karp

    2011-01-01

    This article explores the changing nature of the interaction between computer science and the natural and social sciences.After briefly tracing the history of scientific computation,the article presents the concept of computational lens,a metaphor for a new relationship that is emerging between the world of computation and the world of the sciences.Our main thesis is that,in many scientific fields,the processes being studied can be viewed as computational in nature,in the sense that the processes perform dynamic transformations on information represented as digital data.Viewing natural or engineered systems through the lens of their computational requirements or capabilities provides new insights and ways of thinking.A number of examples are discussed in support of this thesis.The examples are from various fields,including quantum computing,statistical physics,the World Wide Web and the Internet,mathematics,and computational molecular biology.

  4. Anterior segment and retinal OCT imaging with simplified sample arm using focus tunable lens technology (Conference Presentation)

    Science.gov (United States)

    Grulkowski, Ireneusz; Karnowski, Karol; Ruminski, Daniel; Wojtkowski, Maciej

    2016-03-01

    Availability of the long-depth-range OCT systems enables comprehensive structural imaging of the eye and extraction of biometric parameters characterizing the entire eye. Several approaches have been developed to perform OCT imaging with extended depth ranges. In particular, current SS-OCT technology seems to be suited to visualize both anterior and posterior eye in a single measurement. The aim of this study is to demonstrate integrated anterior segment and retinal SS-OCT imaging using a single instrument, in which the sample arm is equipped with the electrically tunable lens (ETL). ETL is composed of the optical liquid confined in the space by an elastic polymer membrane. The shape of the membrane, electrically controlled by a specific ring, defines the radius of curvature of the lens surface, thus it regulates the power of the lens. ETL can be also equipped with additional offset lens to adjust the tuning range of the optical power. We characterize the operation of the tunable lens using wavefront sensing. We develop the optimized optical set-up with two adaptive operational states of the ETL in order to focus the light either on the retina or on the anterior segment of the eye. We test the performance of the set-up by utilizing whole eye phantom as the object. Finally, we perform human eye in vivo imaging using the SS-OCT instrument with versatile imaging functionality that accounts for the optics of the eye and enables dynamic control of the optical beam focus.

  5. Neutronic Design and Measured Performance of the Low Energy Neutron Source (LENS) Target Moderator Reflector Assembly

    CERN Document Server

    Lavelle, C M; Bogdanov, A; Derenchuk, V P; Kaiser, H; Leuschner, M B; Lone, M A; Lozowski, W; Nann, H; Von Przewoski, B; Remmes, N; Rinckel, T; Shin, Y; Snow, W M; Sokol, P E

    2008-01-01

    The Low Energy Neutron Source (LENS) is an accelerator-based pulsed cold neutron facility under construction at the Indiana University Cyclotron Facility (IUCF). The idea behind LENS is to produce pulsed cold neutron beams starting with ~MeV neutrons from (p,n) reactions in Be which are moderated to meV energies and extracted from a small solid angle for use in neutron instruments which can operate efficiently with relatively broad (~1 msec) neutron pulse widths. Although the combination of the features and operating parameters of this source is unique at present, the neutronic design possesses several features similar to those envisioned for future neutron facilities such as long-pulsed spallation sources (LPSS) and very cold neutron (VCN) sources. We describe the underlying ideas and design details of the target/moderator/reflector system (TMR) and compare measurements of its brightness, energy spectrum, and emission time distribution under different moderator configurations with MCNP simulations. Brightnes...

  6. Design of object surveillance system based on enhanced fish-eye lens

    Institute of Scientific and Technical Information of China (English)

    Jianhui Wu; Kuntao Yang; Qiaolian Xiang; Nanyang Zhang

    2009-01-01

    A new method is proposed for the object surveillance system based on the enhanced fish-eye lens and the high speed digital signal processor (DSP). The improved fish-eye lens images an ellipse picture on the charge-coupled device (CCD) surface, which increases both the utilization rate of the 4:3 rectangular CCD and the imaging resolution, and remains the view angle of 183°. The algorithm of auto-adapted renewal background subtraction (ARBS) is also explored to extract the object from the monitoring image. The experimental result shows that the ARBS algorithm has high anti-jamming ability and high resolution, leading to excellent object detecting ability from the enhanced elliptical fish-eye image under varies en-vironments. This system has potential applications in different security monitoring fields due to its wide monitoring space, simple structure, working stability, and reliability.

  7. Microstructure of Lentil Seeds (Lens Culinaris)

    OpenAIRE

    Hughes, Joe S.; Swanson, Barry G.

    1986-01-01

    Scanning electron microscopy (SEM) was used to investigate the microstructure of five cultivars of lentil seeds (Lens culinaris). Lentil cot yledons contain sphericai starch granules surrounded by protein bodies similar to starch granules and protein bodies observed in cotyledons of other food legumes. Examination of the lentil seed coat in cross - section revealed outer palisade and inner parenchyma layers characteris tic of legumes. The subepidermal layer, however, is comprised of hourglass...

  8. Sustained drug released from contact lens

    OpenAIRE

    Ferreira, J. A.; De Oliveira, P.; Silva, P.M. da; Carreira, A; Gil, H; Murta, J. N.

    2009-01-01

    This paper focuses on ophthalmic drug release from a loaded copolymer: the drug is dispersed in the polymeric matrix and entrapped in particles. The copolymer is based in 2-hydroxyethyl methacrylate co-methacrylic acid and silicone is used to prepare the loaded particles. A mathematical model to simulate the drug release is proposed and a qualitative analysis is performed. Experimental results are compared with simulation results. Contact lens made from the presented copolymer ...

  9. Nanoindentation of soft contact lens materials

    OpenAIRE

    Selby, Alastair Phillip

    2012-01-01

    The launch of silicone hydrogel contact lenses has led to a rise in the incidence of mechanically-related clinical complications, which is thought to be due to the increased stiffness of these materials compared to conventional hydrogel lens materials. The mechanical characteristics of hydrogel contact lenses have traditionally been investigated using tensile testing which investigated the bulk material characteristics. This thesis presents a study intended to establish a repeatable method fo...

  10. The Frontier Fields Lens Modeling Comparison Project

    OpenAIRE

    Meneghetti, M.; Natarajan, P.; Coe, D.; Contini, E.; De Lucia, G.; Giocoli, C.; Acebron, A.; S. Borgani(INFN - Trieste, c/o Dipartimento di Astronomia, Univ. di Trieste, Italy); Bradac, M.; Diego, J. M.; Hoag, A.; Ishigaki, M.; Johnson, T. L.; Jullo, E; Kawamata, R

    2016-01-01

    Gravitational lensing by clusters of galaxies offers a powerful probe of their structure and mass distribution. Deriving a lens magnification map for a galaxy cluster is a classic inversion problem and many methods have been developed over the past two decades to solve it. Several research groups have developed techniques independently to map the predominantly dark matter distribution in cluster lenses. While these methods have all provided remarkably high precision mass maps, particularly wi...

  11. Rose-K contact lens for keratoconus

    Directory of Open Access Journals (Sweden)

    Jain Arun

    2007-01-01

    Full Text Available Aim: To report clinical experience and the comparative value of axial and instantaneous topography data in fitting Rose-K design contact lenses in moderate and severe keratoconus. Materials and Methods: Thirty-eight eyes (of 23 patients with keratoconus were fitted with Rose-K design contact lenses and followed up for at least six months or more. Visual acuity with habitual vision correction available was measured. Axial and instantaneous topography maps for each eye were recorded. Contact lens wear comfort was graded on a ten point rating scale every three months. Results: Fourteen (100% moderate keratoconus eyes (average Sim K 48.61 ± 1.24D and 23 of 24 (96% of severe keratoconus eyes (average Sim K 60.88 ± 5.31D were successfully fitted with the Rose-K lenses. Final fit contact lenses in severe keratoconus had statistically significant steeper base curves compared to average axial corneal curvature than in moderate keratoconus eyes. Average simulated corneal curvature on axial maps predicted final fit contact lens base curves significantly better than on instantaneous maps. Thirty-three of the 37 eyes fitted with contact lenses maintained wear comfort over average follow up period of 13 ± 3.5 months. Conclusions: Rose-K design rigid contact lenses are successful in visually rehabilitating 100% of moderate and 96% of severe keratoconus eyes. Most patients (90% maintained contact lens wear comfort. Corneal curvature on axial maps is a better predictive of base curve of final fit contact lens.

  12. Magnetic Resonance Imaging with a Dielectric Lens

    OpenAIRE

    Vazquez, F.; Marrufo, O.; MARTIN,R; Rodriguez, A. O.

    2009-01-01

    Recently, metamaterials have been introduced to improve the signal-to-noise ratio (SNR) of magnetic resonance images with very promising results. However, the use polymers in the generation of high quality images in magnetic resonance imaging has not been fully been investigated. These investigations explored the use of a dielectric periodical array as a lens to improve the image SNR generated with single surface coils. Commercial polycarbonate glazing sheets were used together with a circula...

  13. A stereoscopic lens for digital cinema cameras

    Science.gov (United States)

    Lipton, Lenny; Rupkalvis, John

    2015-03-01

    Live-action stereoscopic feature films are, for the most part, produced using a costly post-production process to convert planar cinematography into stereo-pair images and are only occasionally shot stereoscopically using bulky dual-cameras that are adaptations of the Ramsdell rig. The stereoscopic lens design described here might very well encourage more live-action image capture because it uses standard digital cinema cameras and workflow to save time and money.

  14. Effects of Different Contact Lens Designs on Visual Quality Among the Soft Spherical Contact Lens Users

    Directory of Open Access Journals (Sweden)

    Mustafa Demir

    2013-10-01

    Full Text Available Purpose: To evaluate the effects of different lens designs on visual quality among soft spherical contact lens users. Material and Method: Forty eyes of twenty patients from our contact lens unit were included in this study. Refractive errors of the patients were between -0.50 and -6.0 diopters with 0.05. Total higher order aberration mean rms value was 0.29±0.10 µm without glasses, while it was 0.33±0.10 µm with Balafilcon A lenses and 0.31±0.10 µm with Senofilcon A lenses. Higher order aberration values measured after contact lens application did not show a significant difference for two contact lens designs (p>0.05. Discussion: High and low contrast sensitivity values were better with spectacles compared to contact lenses. We did not observe significant difference in higher order aberration values and visual quality between aspheric and spheric designed lenses. (Turk J Ophthalmol 2013; 43: 321-5

  15. Comparison and Calibration of Mobile Phone Fisheye Lens and Regular Fisheye Lens via Equidistant Model

    Directory of Open Access Journals (Sweden)

    Cumhur Sahin

    2016-01-01

    Full Text Available Nowadays, mobile phones are more than a device that can only satisfy the communication need between people. In addition to providing ease to human lives with various applications, lens kits that can be integrated to mobile phones have recently been introduced. Fisheye lenses that are compliant with mobile phones are one of these new types of equipment. Since fisheye lenses integrated with mobile phones are lightweight and easy to use, they are advantageous. In addition to this advantage, whether fisheye lens and mobile phone combination can be used in a photogrammetric way is experimented, and if so, what will be the result. The main purpose of this study is to test fisheye lens equipment used with mobile phones. In this study, standard calibration of “Olloclip 3 in one” fisheye lens used with iPhone 4S mobile phone and “Nikon FC-E9” fisheye lens used with Nikon Coolpix8700 are compared based on equidistant model. The results of these calibrations are analyzed, using photogrammetric bundle block adjustment. This study suggests a precalibration process of these kinds of hardware for the photogrammetric process in the test field.

  16. Adaptive Liquid Lens Actuated by Droplet Movement

    Directory of Open Access Journals (Sweden)

    Chao Liu

    2014-08-01

    Full Text Available In this paper we report an adaptive liquid lens actuated by droplet movement. Four rectangular PMMA (Polymethyl Methacrylate substrates are stacked to form the device structure. Two ITO (Indium Tin Oxide sheets stick on the bottom substrate. One PMMA sheet with a light hole is inserted in the middle of the device. A conductive droplet is placed on the substrate and touches the PMMA sheet to form a small closed reservoir. The reservoir is filled with another immiscible non-conductive liquid. The non-conductive liquid can form a smooth concave interface with the light hole. When the device is applied with voltage, the droplet stretches towards the reservoir. The volume of the reservoir reduces, changing the curvature of the interface. The device can thus achieve the function of an adaptive lens. Our experiments show that the focal length can be varied from −10 to −159 mm as the applied voltage changes from 0 to 65 V. The response time of the liquid lens is ~75 ms. The proposed device has potential applications in many fields such as information displays, imaging systems, and laser scanning systems.

  17. Thin wetting film lens-less imaging

    International Nuclear Information System (INIS)

    Lens-less imaging has recently attracted a lot of attention as a compact, easy-to-use method to image or detect biological objects like cells, but failed at detecting micron size objects like bacteria that often do not scatter enough light. In order to detect single bacterium, we have developed a method based on a thin wetting film that produces a micro-lens effect. Compared with previously reported results, a large improvement in signal to noise ratio is obtained due to the presence of a micro-lens on top of each bacterium. In these conditions, standard CMOS sensors are able to detect single bacterium, e.g. E. coli, Bacillus subtilis and Bacillus thuringiensis, with a large signal to noise ratio. This paper presents our sensor optimization to enhance the SNR; improve the detection of sub-micron objects; and increase the imaging FOV, from 4.3 mm2 to 12 mm2 to 24 mm2, which allows the detection of bacteria contained in 0.5 μl to 4 μl to 10 μl, respectively. (authors)

  18. Pitfalls in aphakic contact lens fitting

    Directory of Open Access Journals (Sweden)

    Dada Vijay

    1990-01-01

    Full Text Available We examined 23 consecutive cases of unilateral aphakia reporting to the contact lens office for endothelial count and morphology, corneal thickness and toricity. The fellow eye served as a control in all the cases. It was found that there is a significant drop in the central endothelial cell density, and change in the size and shape of the cells. These observations indicate a thermodynamically unstable state. The aphakic corneas were thicker than the controls but not to a significant extent. The cell count and pachymetry had no statistical correlation. Toricity of the aphakic corneas make successful fitting of a lens difficult. Since prolonged use of extended wear gas permeable as well as hydrogel lenses have a deleterious effect on the endothelium it is suggested that a careful case selection be made and strict monitoting carried out at follow up. These corneas are liable for decompensation with only mild noxious stimuli. This article is intended to acquaint the ophthalmologist with the pitfalls in aphakic contact lens fitting so that a cautious follow up may be planned.

  19. Clear Channel Assessment in Integrated Medical Environments

    Directory of Open Access Journals (Sweden)

    Bin Zhen

    2008-03-01

    Full Text Available Complementary WLAN and WPAN technologies as well as other wireless technologies will play a fundamental role in the medical environments to support ubiquitous healthcare delivery. This paper investigates clear channel assessment (CCA and its impact on the coexistence of WLAN (IEEE 802.11 high rate direct sequence spread spectrum (HR/DSSS PHY and WPAN (IEEE 802.15.4b in the 2.4 GHz industrial, scientific, and medical (ISM band. We derived closed-form expressions of both energy-based CCA and feature-based CCA. We qualified unequal sensing abilities between them and termed this inequality asymmetric CCA, which is different from the traditional “hidden node” or “exposed node” issues in the homogeneous network. The energy-based CCA was considered in the considered integrated medical environment because the 2.4 GHz ISM band is too crowded to apply feature-based CCA. The WPAN is oversensitive to the 802.11 HR/DSSS signals and the WLAN is insensitive to the 802.15.4b signals. Choosing an optimal CCA threshold requires some prior knowledge of the underlying signals. In the integrated medical environment we considered here, energy-based CCA can effectively avoid possible packet collisions when they are close within the “heterogeneous exclusive CCA range” (HECR. However, when they are separated beyond the HECR, WPAN can still sense the 802.11 HR/DSSS signals, but WLAN loses its sense to the 802.15.4b signals. The asymmetric CCA leads to WPAN traffic in a position secondary to WLAN traffic.

  20. Clear Channel Assessment in Integrated Medical Environments

    Directory of Open Access Journals (Sweden)

    Hara Shinsuke

    2008-01-01

    Full Text Available Abstract Complementary WLAN and WPAN technologies as well as other wireless technologies will play a fundamental role in the medical environments to support ubiquitous healthcare delivery. This paper investigates clear channel assessment (CCA and its impact on the coexistence of WLAN (IEEE 802.11 high rate direct sequence spread spectrum (HR/DSSS PHY and WPAN (IEEE 802.15.4b in the 2.4 GHz industrial, scientific, and medical (ISM band. We derived closed-form expressions of both energy-based CCA and feature-based CCA. We qualified unequal sensing abilities between them and termed this inequality asymmetric CCA, which is different from the traditional "hidden node" or "exposed node" issues in the homogeneous network. The energy-based CCA was considered in the considered integrated medical environment because the 2.4 GHz ISM band is too crowded to apply feature-based CCA. The WPAN is oversensitive to the 802.11 HR/DSSS signals and the WLAN is insensitive to the 802.15.4b signals. Choosing an optimal CCA threshold requires some prior knowledge of the underlying signals. In the integrated medical environment we considered here, energy-based CCA can effectively avoid possible packet collisions when they are close within the "heterogeneous exclusive CCA range" (HECR. However, when they are separated beyond the HECR, WPAN can still sense the 802.11 HR/DSSS signals, but WLAN loses its sense to the 802.15.4b signals. The asymmetric CCA leads to WPAN traffic in a position secondary to WLAN traffic.

  1. Experimental investigation of pneumatic soil vapor extraction.

    Science.gov (United States)

    Høier, C K; Sonnenborg, T O; Jensen, K H; Kortegaard, C; Nasser, M M

    2007-01-01

    Soil Vapor Extraction (SVE) is a common remediation technique for removing volatile organic compounds from unsaturated contaminated soils. Soil heterogeneities can however cause serious limitations to the applicability of SVE due to air bypassing low permeable areas of the soil, leading to diffusion limitation of the remediation. To enhance removal from areas subject to diffusion limitation a new remediation technique, pneumatic soil vapor extraction, is proposed. In contrast to traditional SVE, in which soil vapor is extracted continuously by a vacuum pump, pneumatic SVE is based on enforcing a sequence of large pressure drops on the system to enhance the recovery from the low-permeable areas. The pneumatic SVE technique was investigated in the laboratory using TCE as a model contaminant. 2D-laboratory tank experiments were performed on homogeneous and heterogeneous sand packs. The heterogeneous packs consisted of a fine sand lens surrounded by a coarser sand matrix. As expected when using traditional SVE, the removal of TCE from the low permeable lens was extremely slow and subject to diffusion limitation. In contrast when pneumatic venting was used removal rates increased by up to 77%. The enhanced removal was hypothesized to be attributed to mixing of the contaminated air inside the lens and generation of net advective transport out of the lens due to air expansion. PMID:16987566

  2. When a Cleared Rape Is Not Cleared: A Multilevel Study of Arrest and Exceptional Clearance.

    Science.gov (United States)

    Walfield, Scott M

    2016-05-01

    As rape remains one of the most underreported and least likely to be cleared of the violent crimes, it is of paramount importance to understand the factors associated with the likelihood of a case being cleared by law enforcement. This study uses data from the National Incident-Based Reporting System (NIBRS) and the Law Enforcement Management and Administrative Statistics (LEMAS), and a multilevel modeling approach to examine the relationship between victim, offender, incident, and police department characteristics contrasting the two types of clearance: arrest and exceptional clearance. The latter occurs due to reasons outside of law enforcement's control and despite being considered cleared, the offender is not arrested, charged, nor turned over for prosecution. Of the 16,231 cleared rapes in 238 departments, nearly half (47%) results in exceptional clearance when the victim refuses to cooperate or when prosecution is declined. Incident-level variables have a greater effect on the likelihood of exceptional clearance than victim and offender variables. The department explained a nontrivial amount of variation in the dependent variable, as 37% of the variance in type of clearance was between-department variation. Implications for future research on exceptional clearance and NIBRS are discussed. PMID:25646164

  3. Clear cell renal cell tumors: Not all that is "clear" is cancer.

    Science.gov (United States)

    Williamson, Sean R; Cheng, Liang

    2016-07-01

    Continued improvement of our understanding of the clinical, histologic, and genetic features of renal cell tumors has progressively evolved renal tumor classification, revealing an expanding array of distinct tumor types with different implications for prognosis, patient counseling, and treatment. Although clear cell renal cell carcinoma is unequivocally the most common adult renal tumor, there is growing evidence that some "clear cell" renal neoplasms, such as exemplified by multilocular cystic clear cell renal neoplasm of low malignant potential (formerly multilocular cystic renal cell carcinoma), do not have the same potential for insidious progression and metastasis, warranting reclassification as low malignant potential tumors or benign neoplasms. Still other novel tumor types such as clear cell papillary renal cell carcinoma have been more recently recognized, which similarly have shown a conspicuous absence of aggressive behavior to date, suggesting that these too may be recategorized as noncancerous or may be premalignant neoplasms. This importance for prognosis is increasingly significant in the modern era, in which renal masses are increasingly found incidentally by imaging techniques at a small tumor size, raising consideration for less aggressive management options guided by renal mass biopsy diagnosis, including imaging surveillance, tumor ablation, or partial nephrectomy. PMID:26988177

  4. 76 FR 45730 - Customer Clearing Documentation and Timing of Acceptance for Clearing

    Science.gov (United States)

    2011-08-01

    ... derivatives clearing organization (DCO) level.\\4\\ \\4\\ See, e.g., 76 FR 3698 (Jan. 20, 2011) (Risk Management.... 39.12(b)(2) to implement this provision.\\7\\ \\7\\ 76 FR 3698 (Jan. 20, 2011) (Risk Management... important risk mitigant. The Commission recently proposed Sec. 39.12(b)(7) regarding time frames...

  5. MODIS Collection 6 Clear Sky Restoral (CSR): Filtering Cloud Mast 'Not Clear' Pixels

    Science.gov (United States)

    Meyer, Kerry G.; Platnick, Steven Edward; Wind, Galina; Riedi, Jerome

    2014-01-01

    Correctly identifying cloudy pixels appropriate for the MOD06 cloud optical and microphysical property retrievals is accomplished in large part using results from the MOD35 1km cloud mask tests (note there are also two 250m subpixel cloud mask tests that can convert the 1km cloudy designations to clear sky). However, because MOD35 is by design clear sky conservative (i.e., it identifies "not clear" pixels), certain situations exist in which pixels identified by MOD35 as "cloudy" are nevertheless likely to be poor retrieval candidates. For instance, near the edge of clouds or within broken cloud fields, a given 1km MODIS field of view (FOV) may in fact only be partially cloudy. This can be problematic for the MOD06 retrievals because in these cases the assumptions of a completely overcast homogenous cloudy FOV and 1-dimensional plane-parallel radiative transfer no longer hold, and subsequent retrievals will be of low confidence. Furthermore, some pixels may be identified by MOD35 as "cloudy" for reasons other than the presence of clouds, such as scenes with thick smoke or lofted dust, and should therefore not be retrieved as clouds. With such situations in mind, a Clear Sky Restoral (CSR) algorithm was introduced in C5 that attempts to identify pixels expected to be poor retrieval candidates. Table 1 provides SDS locations for CSR and partly cloudy (PCL) pixels.

  6. Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Herrero, R.; Miller, D. C.; Kurtz, S. R.; Anton, I.; Sala, G.

    2013-07-01

    A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

  7. Apixaban and atrial fibrillation: no clear advantage.

    Science.gov (United States)

    2014-02-01

    For the prevention of thromboembolic events in patients with atrial fibrillation and a high thrombotic risk, the standard treatment is warfarin, an anticoagulant. Dabigatran, a thrombin inhibitor, is the alternative when warfarin fails to maintain the INR within the therapeutic range. Patients with a moderate thrombotic risk may receive either warfarin or low-dose aspirin. Apixaban, a factor Xa inhibitor anticoagulant, has been authorised in the European Union for use in patients with non-valvular atrial fibrillation and a moderate or high risk of thrombosis. In a double-blind, randomised non-inferiority trial versus warfarin in 18 201 patients, the incidence of stroke or systemic embolism was lower in the apixaban group (average 1.3 versus 1.6 events per 100 patient-years; p = 0.01). This difference was mainly due to a lower incidence of haemorrhagic stroke and did not result in a clear decline in mortality. In addition, these results are undermined by multiple methodological flaws. Clinical evaluation included no trials comparing apixaban with dabigatran; any indirect comparison would be risky given the poor quality of the clinical assessment of both drugs in atrial fibrillation. A double-blind, randomised trial including 5598 patients compared apixaban with aspirin but provided little information on these options in patients with a moderate risk of thrombosis, as most patients were at high risk. In clinical trials, major bleeding events were less frequent with apixaban than with warfarin (average 2.1 versus 3.1 events per 100 patient-years), but they were more frequent with apixaban than with aspirin (1.4 versus 0.9 events per 100 patient-years). In 2013, there is no way of monitoring the anticoagulant activity of apixaban in routine clinical practice, and there is no antidote in case of overdose; the same is true for dabigatran. Apixaban is a substrate for various cytochrome P450 isoenzymes and for P-glycoprotein, creating a risk of multiple drug

  8. Effect of selenite on 86Rb uptake by rat lens

    International Nuclear Information System (INIS)

    The effect was observed in vitro of selenite on the uptake of 86Rb by the lens in two weeks old and adult rats. Also measured was the uptake of 86Rb by the lens in vitro in 30-days old rats with cataracts induced by the administration of selenite at day 14 after birth and in control animals of the same age. Selenite in a concentration of 0.4 mM and more caused an insignificant decrease in 86Rb uptake by the lens in adult rats while in the lens of young rats the uptake decreased significantly already at concentrations lower by two orders. Lenses with cataracts took up significantly less 86Rb than transparent lenses; body weight, the weight of the fresh lens and its dry mass decreased while the water content in the lens was higher as compared with control groups. (author). 2 tabs., 26 refs

  9. Multipoint photonic doppler velocimetry using optical lens elements

    Science.gov (United States)

    Frogget, Brent Copely; Romero, Vincent Todd

    2014-04-29

    A probe including a fisheye lens is disclosed to measure the velocity distribution of a moving surface along many lines of sight. Laser light, directed to the surface and then reflected back from the surface, is Doppler shifted by the moving surface, collected into fisheye lens, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to an index-matching lens and eventually to a fisheye lens. The fiber array flat polished and coupled to the index-matching lens using index-matching gel. Numerous fibers in a fiber array project numerous rays through the fisheye lens which in turn project many measurement points at numerous different locations to establish surface coverage over a hemispherical shape with very little crosstalk.

  10. Forensic Analysis of a Contact Lens in a Murder Case.

    Science.gov (United States)

    Zwerling, Charles S

    2016-03-01

    Contact lenses have had rare relevance in trials and/or investigations. After 5 years of burial, orbital remnants were retrieved from an exhumed body and subsequently identified as a key piece of material evidence in a murder trial. The exhumed case materials were evaluated under laboratory conditions and were determined to be contact lens remnants. Contact lens fracture and burial simulation studies were performed to provide additional corroboration of the physical findings of the exhumed contact lens remnants. This material evidence was instrumental in providing factual proof refuting the defendant's testimony in the murder trial. A brief history of contact lens composition and use is provided for understanding the methods and observational results. This forensic case study represents the first published documentation of a contact lens from an exhumed body being used in a murder investigation and establishes an operational procedure for future forensic contact lens examinations.

  11. Shape measurement of aspheric plastic lens with large angle

    Institute of Scientific and Technical Information of China (English)

    Dagang Huang; Heng Zhang; Shah-Rong Lee; Baoguang Wang

    2005-01-01

    @@ In this paper, according to the features of easy distortion and scratch for aspheric plastic lens, a noncontact measuring method is raised to test error in shape of the lens. Namely, the distance between a template and its image reflected with tested lens can be measured in nearly the vertical direction of the lens axis when the two-dimensional (2D) template is put near the measured surface. Then, the outline of the central cross-section could be obtained by calculating and curve fitting. Furthermore, three-dimensional (3D) surface can be imitated through rotating the component. A new fitting method of drift measurement is presented to prevent reducing precision when the lens and the template are fixed. The template is adjusted according to the position of the lens. The measurement precision is in the order of magnitued of sub-microns. Rotationally symmetric convex aspheric surface with any angle can be measured by this method.

  12. Lens dislocation has a possible relationship with laser iridotomy.

    Science.gov (United States)

    Mutoh, Tetsuya; Barrette, Kevin F; Matsumoto, Yukihiro; Chikuda, Makoto

    2012-01-01

    We report our recent experience of four eyes with spontaneous lens dislocation in four patients with no history of trauma or any systemic disease associated with zonular dialysis. Lens dislocation developed with 0.5 to 6 months following laser iridotomy. All patients were male and two eyes were complicated with acute primary angle closure glaucoma preoperatively. Case 1 showed bilateral lens dislocation, while cases 2 and 3 involved unilateral lens dislocation. Cases 2 and 3 showed lenses completely dislocated into the vitreous cavity. All cases needed lens removal and scleral fixation of intraocular lenses. Final visual acuity was 1.2 in all cases. We suspect that laser iridotomy may induce localized zonular dialysis that results in progressive zonular weakness, leading to lens dislocation. PMID:23271880

  13. Characterization and localization of side population cells in the lens

    OpenAIRE

    Oka, Mikako; Toyoda, Chizuko; Kaneko, Yuka; Nakazawa, Yosuke; Aizu-Yokota, Eriko; Takehana, Makoto

    2010-01-01

    Purpose Side population (SP) cells were isolated and the possibility whether lens epithelial cells contain stem cells was investigated. Methods Mouse lens epithelial cells were stained by Hoechst 33342 and then sorted by fluorescence-activated cell sorting (FACS). The expression of stem cell markers in sorted SP cells and the main population of epithelial cells were analyzed by quantitative real-time PCR. Localization of SP cells in the mouse lens was studied by fluorescence microscopy. Resul...

  14. Microbial Keratitis: Could Contact Lens Material Affect Disease Pathogenesis?

    OpenAIRE

    Evans, David J.; Fleiszig, Suzanne M. J.

    2013-01-01

    Microbial keratitis is a sight-threatening complication associated with contact lenses. The introduction of silicone hydrogel lens materials with increased oxygen transmission to the ocular surface has not significantly altered the incidence of microbial keratitis. These data suggest that alternate, or additional, predisposing factors involving lens wear must be addressed to reduce or eliminate these infections. The contact lens can provide a surface for microbial growth in situ, and can also...

  15. Ring lens for focusing ion beams to uniform densities

    International Nuclear Information System (INIS)

    An electrostatic lens was designed and built to focus a beam of positive ions into uniform density on a target. The lens has two concentric field regions with a grid separating the inner zero field from the outer radial field. For proper operation the incident ions must emanate with axial symmetry and Gaussian or similar divergence from a small source. An appendix is included on the symmetrization of elliptical beams by a quadrupole singlet lens. (U.S.)

  16. Hybridizing Conversational and Clear Speech to Investigate the Source of Increased Intelligibility in Speakers with Parkinson's Disease

    Science.gov (United States)

    Tjaden, Kris; Kain, Alexander; Lam, Jennifer

    2014-01-01

    Purpose: A speech analysis-resynthesis paradigm was used to investigate segmental and suprasegmental acoustic variables explaining intelligibility variation for 2 speakers with Parkinson's disease (PD). Method: Sentences were read in conversational and clear styles. Acoustic characteristics from clear sentences were extracted and applied to…

  17. An Ultrasonic Lens Design Based on Prefractal Structures

    Directory of Open Access Journals (Sweden)

    Sergio Castiñeira-Ibáñez

    2016-04-01

    Full Text Available The improvement in focusing capabilities of a set of annular scatterers arranged in a fractal geometry is theoretically quantified in this work by means of the finite element method (FEM. Two different arrangements of rigid rings in water are used in the analysis. Thus, both a Fresnel ultrasonic lens and an arrangement of rigid rings based on Cantor prefractals are analyzed. Results show that the focusing capacity of the modified fractal lens is better than the Fresnel lens. This new lens is believed to have potential applications for ultrasonic imaging and medical ultrasound fields.

  18. 600 Volt Stretched Lens Array for Solar Electric Propulsion Project

    Data.gov (United States)

    National Aeronautics and Space Administration — ENTECH, Auburn, NASA, and others have recently developed a new space photovoltaic array called the Stretched Lens Array (SLA), offering unprecedented performance...

  19. Reduction of pantethine in rabbit ocular lens homogenate.

    Science.gov (United States)

    Fisher, D H; Szulc, M E

    1997-02-01

    In several animal models, preliminary studies have indicated that pantethine may inhibit cataract formation. Therefore, preclinical trials need to be conducted to study the pharmacology of pantethine in the ocular lens and to establish its efficacy. Since pantethine, which is a disulfide, can undergo a variety of chemical modifications such as reduction and formation of mixed disulfides, a detailed study was first conducted to determine the stability of pantethine in rabbit lens homogenate. A knowledge of the stability of pantethine in lens homogenate was necessary to establish if pantethine could be metabolized in the time it takes to harvest and homogenize a lens. The results of this study will be used to establish a protocol for harvesting and homogenizing lens samples. Pantethine (100 microM) is completely reduced to pantetheine in rabbit lens homogenate in about 16 min. About 1.5% of the pantethine added to lens homogenate forms a mixed disulfide with lens proteins, and the remainder is found in the supernatant. The supernatant pantethine concentration decreases exponentially as a function of time, and the terminal half-life for this process is 3.3 min. The free supernatant pantetheine concentration increases in pseudo first order manner as a function of time with a rate constant of 4.3 min. Pantethinase activity is not significant, because the free supernatant pantetheine concentration did not decrease. The exact mechanism of pantethine reduction in rabbit lens homogenate remains to be determined. PMID:9127277

  20. Lens regeneration in axolotl: new evidence of developmental plasticity

    Directory of Open Access Journals (Sweden)

    Suetsugu-Maki Rinako

    2012-12-01

    Full Text Available Abstract Background Among vertebrates lens regeneration is most pronounced in newts, which have the ability to regenerate the entire lens throughout their lives. Regeneration occurs from the dorsal iris by transdifferentiation of the pigment epithelial cells. Interestingly, the ventral iris never contributes to regeneration. Frogs have limited lens regeneration capacity elicited from the cornea during pre-metamorphic stages. The axolotl is another salamander which, like the newt, regenerates its limbs or its tail with the spinal cord, but up until now all reports have shown that it does not regenerate the lens. Results Here we present a detailed analysis during different stages of axolotl development, and we show that despite previous beliefs the axolotl does regenerate the lens, however, only during a limited time after hatching. We have found that starting at stage 44 (forelimb bud stage lens regeneration is possible for nearly two weeks. Regeneration occurs from the iris but, in contrast to the newt, regeneration can be elicited from either the dorsal or the ventral iris and, occasionally, even from both in the same eye. Similar studies in the zebra fish concluded that lens regeneration is not possible. Conclusions Regeneration of the lens is possible in the axolotl, but differs from both frogs and newts. Thus the axolotl iris provides a novel and more plastic strategy for lens regeneration.

  1. Seeing lens imaging as a superposition of multiple views

    Science.gov (United States)

    Grusche, Sascha

    2016-01-01

    In the conventional approach to lens imaging, rays are used to map object points to image points. However, many students want to think of the image as a whole. To answer this need, Kepler’s ray drawing is reinterpreted in terms of shifted camera obscura images. These images are uncovered by covering the lens with pinholes. Thus, lens imaging is seen as a superposition of sharp images from different viewpoints, so-called elemental images. This superposition is simulated with projectors, and with transparencies. Lens ray diagrams are constructed based on elemental images; the conventional construction method is included as a special case.

  2. Seeing lens imaging as a superposition of multiple views

    CERN Document Server

    Grusche, Sascha

    2015-01-01

    In the conventional approach to lens imaging, rays are used to map object points to image points. However, many students have a need to think of the image as a whole. To answer this need, lens imaging is reinterpreted as a superposition of sharp images from different viewpoints. These so-called elemental images are uncovered by covering the lens with a pinhole array. Rays are introduced to connect elemental images. Lens ray diagrams are constructed based on bundles of elemental images. The conventional construction method is included as a special case. The proposed approach proceeds from concrete images to abstract rays.

  3. Assessing the elasticity change of cataract lens with OCE

    Science.gov (United States)

    Wu, Chen; Liu, Chih-Hao; Raghunathan, Raksha; Singh, Manmohan; Li, Jiasong; Han, Zhaolong; Larin, Kirill V.

    2016-03-01

    Cataract is one of the most common degenerative diseases that causes blindness. Careful quantification of lens biomechanical properties can greatly assist in early detection of the disease as well as personalization of treatment procedures. In this study, we utilize a phase-sensitive optical coherence elastography (OCE) system to assess the effects of the cold cataract on the biomechanical properties of porcine crystalline lens in vitro. Relaxation rates of air puff induced elastic waves were measured on the same crystalline lens with and without cold cataract. Results demonstrate that the relaxation rate and, thus, associated elasticity of the porcine lens, increased due to the presence of cold cataract.

  4. A safe method of ciliary sulcus fixation of foldable intraocular lens using a ciliary sulcus guide.

    Science.gov (United States)

    Can, Ertuğrul; Gül, Adem; Birinci, Hakkı

    2016-08-01

    To describe a novel technique for implantation of intraocular lens in the absence of capsular support using a ciliary sulcus guide. Based on the anatomic knowledge of the ciliary sulcus and the sclera, a new instrument was developed to pierce the needle safely through the ciliary sulcus and sclera. While the foldable lens is stored inside the cartridge, the leading haptic is sutured with a cow-hitch knot. The needle is then inserted into the ciliary sulcus guide. The tip of the guide is inserted from the corneal incision and proceeded under the iris to touch and fit the ciliary sulcus. The needle is pushed from back side. The needle comes out at precise point at the sclera. Implantation of the lens was performed through a 2.8 mm clear cornea incision using the injector. The trailing haptic is tied after implantation, and then the same procedure is performed at the opposite side. We performed this technique to 15 aphakic eyes without sufficient capsular support. There was no bleeding or other intraoperative complication. All the points coming out the sclera were between 2 and 2.5 mm from the limbus. The ab interno technique for scleral fixation of IOL is quicker, easier and less traumatic then ab externo techniques. A new ciliary sulcus guide which is usable with both straight and curved needles eliminates the blind maneuvers of ab interno technique and makes this technique more safe and precise.

  5. Super-oscillation focusing lens based on continuous amplitude and binary phase modulation.

    Science.gov (United States)

    Wen, Zhongquan; He, Yinghu; Li, Yuyan; Chen, Li; Chen, Gang

    2014-09-01

    In this paper, we numerically demonstrate the advantage of utilizing continuous amplitude and phase modulation in super-oscillation focusing lens design. Numerical results show that compared with simple binary amplitude modulation, continuous amplitude and phase modulation can greatly improve the super-oscillation focusing performance by increasing the central lobe intensity and the ratio of its energy to the total energy, reducing the sidelobe intensity, and substantially extending the field of view. Our study also reveals the role of phase distribution in reducing the spatial frequency bandwidth of the super-oscillation optical field on the focal plane. Based on continuous amplitude and binary phase modulation, a lens was designed with double layer metal slit array for wavelength of 4.6 µm. COMSOL is used to carry out the 2D simulation. The lens focal length is 40.18λ and the focal spot FWHM is 0.308λ. Two largest sidelobes are located right next to the central lobe with intensity about 40% of the central lobe intensity. Except for the two sidelobes, other sidelobes have intensity less than 25% of the central lobe intensity, which leads to a clear field of view on the whole focal plane. PMID:25321591

  6. Experimental investigation and analysis on a concentrating solar collector using linear Fresnel lens

    International Nuclear Information System (INIS)

    A concentrating solar collector based on linear Fresnel lens is investigated experimentally in this paper. This solar collector is expected to acquire a higher thermal efficiency at a relatively high temperature level than the commonly used flat-plate or evacuated tube solar collectors. Experimental results show that the thermal efficiency is about 50% when the conversion temperature (water) is 90 deg. C. The test shows that the indication of lost energy is 0.578 W/m2 K, which is much smaller than that of commonly used evacuated tube solar collector without concentrating. In order to make analysis, a mathematical model for evacuated tube absorber heated by linear Fresnel lens has been built. The validation shows that the model agrees with the experimental data well. The analysis indicates that Fresnel lens collector with evacuated tube absorber has good efficiency (50%) in clear day even when the conversion temperature approaches 200 deg. C. The influence of ambient conditions and the percent of different types of energy loss, etc., are also analyzed.

  7. FOCUSING BY A HIGH-POWER, LOW-FRESNEL-NUMBER LENS - THE FLY FACET LENS

    NARCIS (Netherlands)

    STAVENGA, DG; VANHATEREN, JH

    1991-01-01

    Diffraction by fly facet lenses has been investigated by photographing the diffraction patterns at various distances from a facet lens whose power was estimated to be 2.03 x 10(4) D. We studied three different aperture diameters with Fresnel numbers of the order of unity. A large focal shift was pro

  8. Focusing by a high-power, low-Fresnel-number lens : the fly facet lens

    NARCIS (Netherlands)

    Stavenga, D.G.; Hateren, J.H. van

    1991-01-01

    Diffraction by fly facet lenses has been investigated by photographing the diffraction patterns at various distances from a facet lens whose power was estimated to be 2.03 x 10(4) D. We studied three different aperture diameters with Fresnel numbers of the order of unity. A large focal shift was pro

  9. The BOSS Emission-Line Lens Survey. IV. : Smooth Lens Models for the BELLS GALLERY Sample

    CERN Document Server

    Shu, Yiping; Mao, Shude; Kochanek, Christopher S; Pérez-Fournon, Ismael; Oguri, Masamune; Montero-Dorta, Antonio D; Cornachione, Matthew A; Marques-Chaves, Rui; Zheng, Zheng; Brownstein, Joel R; Ménard, Brice

    2016-01-01

    We present \\textsl{Hubble Space Telescope} (\\textsl{HST}) F606W-band imaging observations of 21 galaxy-Ly$\\alpha$ emitter lens candidates in the Baryon Oscillation Spectroscopic Survey (BOSS) Emission-Line Lens Survey (BELLS) for GALaxy-Ly$\\alpha$ EmitteR sYstems (BELLS GALLERY) survey. 17 systems are confirmed to be definite lenses with unambiguous evidence of multiple imaging. The lenses are primarily massive early-type galaxies (ETGs) at redshifts of approximately $0.55$, while the lensed sources are Ly$\\alpha$ emitters (LAEs) at redshifts from 2 to 3. Although the \\textsl{HST} imaging data are well fit by smooth lens models consisting of singular isothermal ellipsoids in an external shear field, a thorough exploration of dark substructures in the lens galaxies is required. The Einstein radii of the BELLS GALLERY lenses are on average $60\\%$ larger than those of the BELLS lenses because of the much higher source redshifts which will allow a detailed investigation of the radius evolution of the mass profile...

  10. Magnetic Resonance Imaging with a Dielectric Lens

    CERN Document Server

    Vazquez, F; Martin, R; Rodriguez, A O

    2009-01-01

    Recently, metamaterials have been introduced to improve the signal-to-noise ratio (SNR) of magnetic resonance images with very promising results. However, the use polymers in the generation of high quality images in magnetic resonance imaging has not been fully been investigated. These investigations explored the use of a dielectric periodical array as a lens to improve the image SNR generated with single surface coils. Commercial polycarbonate glazing sheets were used together with a circular coil to generate phantom images at 3 Tesla on a clinical MR imager.

  11. Comparison of Strong Gravitational Lens Model Software II. HydraLens: Computer-Assisted Strong Gravitational Lens Model Generation and Translation

    CERN Document Server

    Lefor, Alsn T

    2015-01-01

    The behavior of strong gravitational lens model software in the analysis of lens models is not necessarily consistent among the various software available, suggesting that the use of several models may enhance the understanding of the system being studied. Among the publicly available codes, the model input files are heterogeneous, making the creation of multiple models tedious. An enhanced method of creating model files and a method to easily create multiple models, may increase the number of comparison studies. HydraLens simplifies the creation of model files for four strong gravitational lens model software packages, including Lenstool, Gravlens/Lensmodel, glafic and PixeLens, using a custom designed GUI for each of the four codes that simplifies the entry of the model for each of these codes, obviating the need for user manuals to set the values of the many flags and in each data field. HydraLens is designed in a modular fashion, which simplifies the addition of other strong gravitational lens codes in th...

  12. Fusarium and Candida albicans biofilms on soft contact lenses: model development, influence of lens type and susceptibility to lens care solutions

    Science.gov (United States)

    Fungal keratitis is commonly caused by Fusarium species, while cases of Candida-associated keratitis are less frequent. Recent outbreaks of Fusarium keratitis were associated with contact lens wear and with MoistureLoc contact lens care solution, and biofilm formation on contact lens/lens cases was...

  13. High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients

    Directory of Open Access Journals (Sweden)

    Tomris Sengor

    2011-03-01

    Full Text Available Tomris Sengor, Sevda Aydin Kurna, Suat Aki, Yelda ÖzkurtFatih Sultan Mehmet Training and Research Hospital, Istanbul, TurkeyBackground: The aim of the study was to examine the clinical success of high Dk (oxygen permeability piggyback contact lens (PBCL systems for the correction of contact lens intolerant keratoconus patients.Methods: Sixteen patients (29 eyes who were not able to wear gas-permeable rigid lenses were included in this study. Hyper Dk silicone hydrogel (oxygen transmissibility or Dk/t = 150 units and fluorosilicone methacrylate copolymer (Dk/t = 100 units lenses were chosen as the PBCL systems. The clinical examinations included visual acuity and corneal observation by biomicroscopy, keratometer reading, and fluorescein staining before and after fitting the PBCL system.Results: Indications for using PBCL system were: lens stabilization and comfort, improving comfort, and adding protection to the cone. Visual acuities increased significantly in all of the patients compared with spectacles (P = 0. Improvement in visual acuity compared with rigid lenses alone was recorded in 89.7% of eyes and no alteration of the visual acuity was observed in 10.3% of the eyes. Wearing time of PBCL systems for most of the patients was limited time (mean 6 months, range 3–12 months; thereafter they tolerated rigid lenses alone except for 2 patients.Conclusion: The PBCL system is a safe and effective method to provide centering and corneal protection against mechanical trauma by the rigid lenses for keratoconus patients and may increase contact lens tolerance.Keywords: piggyback contact lens, keratoconus, irregular astigmatism

  14. Performance of a slow positron beam using a hybrid lens design

    International Nuclear Information System (INIS)

    The University of Hong Kong positron beam employs conventional magnetic field transport to the target, but has a special hybrid lens design around the positron moderator that allows the beam to be focused to millimeter spot sizes at the target. The good focusing capabilities of the beam are made possible by extracting work-function positrons from the moderator in a magnetic field free region using a conventional Soa lens thus minimizing beam canonical angular momentum. An Einzel lens is used to focus the positrons into the magnetic funnel at the end of transportation magnetic field while at the same time bringing up the beam energy to the intermediate value of 7.5 keV. The beam is E x B filtered at this intermediate energy. The final beam energy is obtained by floating the Soa-Einzel system, E x B filter and flight tube, and accelerating the positrons just before the target. External beam steering saddle coils fine tune the position, and the magnetic field around the target chamber is adjusted so as to keep one of the beam foci always on the target. The system is fully computer controlled. Variable energy-Doppler broadened annihilation radiation (VEDBAR) data for a GaN sample are shown which demonstrate the performance of the positron beam system

  15. The Effect of Contact Lens Usage on Corneal Biomechanical Parameters in Keratoconus Patients

    Directory of Open Access Journals (Sweden)

    Ali Bülent Çankaya

    2012-05-01

    Full Text Available Pur po se: To determine and compare the corneal biomechanical properties in keratoconus patients using rigid gas permeable contact lenses and keratoconus patients who do not use contact lenses. Ma te ri al and Met hod: The study consisted of 70 healthy controls (Group A, 27 ketatoconus subjects who do not use contact lens (Group B and 36 rigid gas permeable contact lens using keratoconic patients (Group C. Corneal viscoelastic parameters were measured with an Ocular response analyzer (ORA. Central corneal thickness was measured with an ultrasonic pachymeter. The differences in ORA parameters between the groups were compared. Re sults: The mean corneal hysteresis (CH in Groups A, B, and C were 10.3±1.5 mm Hg, 7.8±1.4 mm Hg, and 7.4±1.2 mm Hg, respectively. The differences in mean CH between Group A and the other two groups were statistically significant (p<0.01 for both comparisons, but no statistically significant difference was found between groups B and C in terms of mean CH (p=0.61. The mean corneal resistance factor (CRF was 10.7±1.9 in Group A compared with 6.6±1.6 in Group B and 6.1±1.5 in Group C. The differences in mean CRF between Group A and the other two groups were statistically significant (p<0.01 for both comparisons. There was no significant difference in CRF between the keratoconus eyes with or without rigid gas permeable contact lens usage (p=0.57. Dis cus si on: Our results suggest that ORA-generated parameters may be different in subjects with keratoconus. Corneal biomechanical parameters did not demonstrate a clear trend of change with rigid gas permeable contact lens usage. (Turk J Ophthalmol 2012; 42: 197-201

  16. Stochastic heterogeneity mapping around a Mediterranean salt lens

    Directory of Open Access Journals (Sweden)

    G. G. Buffett

    2010-01-01

    Full Text Available We present the first application of stochastic heterogeneity mapping based on the band-limited von Kármán function to a seismic reflection stack of a Mediterranean water eddy (meddy, a large salt lens of Mediterranean water. This process extracts two stochastic parameters directly from the reflectivity field of the seismic data: the Hurst number, which ranges from 0 to 1, and the correlation length (scale length. Lower Hurst numbers represent a richer range of scale lengths and correspond to a broader range of reflection events. The Hurst number estimate for the top of the meddy (0.39 compares well with recent theoretical work, which required values between 0.25 and 0.5 to model internal wave surfaces in open ocean conditions based on simulating a Garrett-Munk spectrum (GM76 slope of −2. Varying stochastic parameters, which correspond to different spectral slopes in the Garrett-Munk spectrum (horizontal wavenumber spectrum, can therefore provide an estimate of different internal wave scales from seismic data alone.

  17. Atomic force microscopy and Langmuir–Blodgett monolayer technique to assess contact lens deposits and human meibum extracts☆

    Science.gov (United States)

    Hagedorn, Sarah; Drolle, Elizabeth; Lorentz, Holly; Srinivasan, Sruthi; Leonenko, Zoya; Jones, Lyndon

    2015-01-01

    Purpose The purpose of this exploratory study was to investigate the differences in meibomian gland secretions, contact lens (CL) lipid extracts, and CL surface topography between participants with and without meibomian gland dysfunction (MGD). Methods Meibum study: Meibum was collected from all participants and studied via Langmuir–Blodgett (LB) deposition with subsequent Atomic Force Microscopy (AFM) visualization and surface roughness analysis. CL Study: Participants with and without MGD wore both etafilcon A and balafilcon A CLs in two different phases. CL lipid deposits were extracted and analyzed using pressure-area isotherms with the LB trough and CL surface topographies and roughness values were visualized using AFM. Results Meibum study: Non-MGD participant meibum samples showed larger, circular aggregates with lower surface roughness, whereas meibum samples from participants with MGD showed more lipid aggregates, greater size variability and higher surface roughness. CL Study: Worn CLs from participants with MGD had a few large tear film deposits with lower surface roughness, whereas non-MGD participant-worn lenses had many small lens deposits with higher surface roughness. Balafilcon A pore depths were shallower in MGD participant worn lenses when compared to non-MGD participant lenses. Isotherms of CL lipid extracts from MGD and non-MGD participants showed a seamless rise in surface pressure as area decreased; however, extracts from the two different lens materials produced different isotherms. Conclusions MGD and non-MGD participant-worn CL deposition were found to differ in type, amount, and pattern of lens deposits. Lipids from MGD participants deposited irregularly whereas lipids from non-MGD participants showed more uniformity. PMID:25620317

  18. Radiation dose to the eye lens

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; D. Nielsen, Kamilla;

    2015-01-01

    might avoid including the eye in the CT scan without losing sufficient visualization of the scull base. The aim of this study was to evaluate the possibility of decreasing the radiation dose to the eye lens, simply by changing the head position, when doing the PET/CT scan from the base of the scull...... to the proximal femur. Methods and materials: The study was performed using a human like whole body phantom with electronic dosimetry units placed upon each eye to detect the exact radiation dose to the eye lens during each scan. The phantom’s head was placed in two different positions, (a) elevated with a small...... pillow below the head (standard), and (b) kipped backwards with the pillow below the neck (kipped). For each head position, CT scans were repeated 5 times with both a low dose and a high dose CT protocol; in this way, a total of 20 CT scans were performed. Robust standard errors were used in order...

  19. Tubular astigmatism-tunable fluidic lens.

    Science.gov (United States)

    Kopp, Daniel; Zappe, Hans

    2016-06-15

    We demonstrate a new means to fabricate three-dimensional liquid lenses which may be tuned in focal length and astigmatism. Using actuation by electrowetting-on-dielectrics, astigmatism in arbitrary directions may be tuned independently, with almost no cross talk between orthogonal orientations. The lens is based on electrodes structured on planar polyimide foils and subsequently rolled, enabling high-resolution patterning of complex electrodes along the azimuthal and radial directions of the lens. Based on a design established through fluidic and optical simulations, the astigmatism tuning is experimentally verified by a change of the corresponding Zernike coefficients measured using a Shack-Hartmann wavefront sensor. It was seen that the back focal length can be tuned by 5 mm and 0° and 45° astigmatism by 3 μm through application of voltages in the range of 50  Vrms. It was observed that the cross talk with other aberrations is very low, suggesting a novel means for astigmatism control in imaging systems.

  20. Curiosity's Mars Hand Lens Imager (MAHLI) Investigation

    Science.gov (United States)

    Edgett, Kenneth S.; Yingst, R. Aileen; Ravine, Michael A.; Caplinger, Michael A.; Maki, Justin N.; Ghaemi, F. Tony; Schaffner, Jacob A.; Bell, James F.; Edwards, Laurence J.; Herkenhoff, Kenneth E.; Heydari, Ezat; Kah, Linda C.; Lemmon, Mark T.; Minitti, Michelle E.; Olson, Timothy S.; Parker, Timothy J.; Rowland, Scott K.; Schieber, Juergen; Sullivan, Robert J.; Sumner, Dawn Y.; Thomas, Peter C.; Jensen, Elsa H.; Simmonds, John J.; Sengstacken, Aaron J.; Willson, Reg G.; Goetz, Walter

    2012-09-01

    The Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) investigation will use a 2-megapixel color camera with a focusable macro lens aboard the rover, Curiosity, to investigate the stratigraphy and grain-scale texture, structure, mineralogy, and morphology of geologic materials in northwestern Gale crater. Of particular interest is the stratigraphic record of a ˜5 km thick layered rock sequence exposed on the slopes of Aeolis Mons (also known as Mount Sharp). The instrument consists of three parts, a camera head mounted on the turret at the end of a robotic arm, an electronics and data storage assembly located inside the rover body, and a calibration target mounted on the robotic arm shoulder azimuth actuator housing. MAHLI can acquire in-focus images at working distances from ˜2.1 cm to infinity. At the minimum working distance, image pixel scale is ˜14 μm per pixel and very coarse silt grains can be resolved. At the working distance of the Mars Exploration Rover Microscopic Imager cameras aboard Spirit and Opportunity, MAHLI's resolution is comparable at ˜30 μm per pixel. Onboard capabilities include autofocus, auto-exposure, sub-framing, video imaging, Bayer pattern color interpolation, lossy and lossless compression, focus merging of up to 8 focus stack images, white light and longwave ultraviolet (365 nm) illumination of nearby subjects, and 8 gigabytes of non-volatile memory data storage.

  1. Scleral lens for keratoconus: technology update

    Directory of Open Access Journals (Sweden)

    Rathi VM

    2015-10-01

    Full Text Available Varsha M Rathi,1 Preeji S Mandathara,2 Mukesh Taneja,1 Srikanth Dumpati,1 Virender S Sangwan1 1L V Prasad Eye Institute, Hyderabad, India; 2School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia Abstract: Scleral lenses are large diameter lenses which rest over the sclera, unlike the conventional contact lenses which rest on the cornea. These lenses are fitted to not touch the cornea and there is a space created between the cornea and the lens. These lenses are inserted in the eyes after filling with sterile isotonic fluid. Generally, scleral contact lenses are used for high irregular astigmatism as seen in various corneal ectatic diseases such as keratoconus, pellucid marginal degeneration, or/and as liquid bandage in ocular surface disorders. In this article, we review the new developments, that have taken place over the years, in the field of scleral contact lenses as regard to new designs, materials, manufacturing technologies, and fitting strategies particularly for keratoconus. Keywords: keratoconus, scleral lens, technology update, PROSE

  2. Tubular astigmatism-tunable fluidic lens.

    Science.gov (United States)

    Kopp, Daniel; Zappe, Hans

    2016-06-15

    We demonstrate a new means to fabricate three-dimensional liquid lenses which may be tuned in focal length and astigmatism. Using actuation by electrowetting-on-dielectrics, astigmatism in arbitrary directions may be tuned independently, with almost no cross talk between orthogonal orientations. The lens is based on electrodes structured on planar polyimide foils and subsequently rolled, enabling high-resolution patterning of complex electrodes along the azimuthal and radial directions of the lens. Based on a design established through fluidic and optical simulations, the astigmatism tuning is experimentally verified by a change of the corresponding Zernike coefficients measured using a Shack-Hartmann wavefront sensor. It was seen that the back focal length can be tuned by 5 mm and 0° and 45° astigmatism by 3 μm through application of voltages in the range of 50  Vrms. It was observed that the cross talk with other aberrations is very low, suggesting a novel means for astigmatism control in imaging systems. PMID:27304276

  3. Non-linear cluster lens reconstruction

    CERN Document Server

    Kaiser, N

    1994-01-01

    We develop a method for general non-linear cluster lens reconstruction using the observable distortion of background galaxies. The distortion measures the combination \\gamma/(1-\\kappa) of shear \\gamma and surface density \\kappa. From this we obtain an expression for the gradient of \\log (1 - \\kappa) in terms of directly measurable quantities. This allows one to reconstruct 1 - \\kappa up to an arbitrary constant multiplier. Recent work has emphasised an ambiguity in the relation between the distortion and \\gamma/(1-\\kappa). Here we show that the functional relation depends only on the parity of the images, so if one has data extending to large radii, and if the critical lines can be visually identified (as lines along which the distortion diverges), this ambiguity is resolved. Moreover, we show that for a generic 2-dimensional lens it is possible to locally determine the parity from the distortion. The arbitrary multiplier, which may in fact take a different value in each region bounded by the contour \\kappa =...

  4. Achromatic Fresnel Lens with Improved Efficiency for PV Systems

    Directory of Open Access Journals (Sweden)

    Mario González Montes

    2014-01-01

    Full Text Available This work is aimed to design and evaluate different achromatic Fresnel lens solutions capable of operating as concentrators aimed at photovoltaic cells systems. Throughout this study, the theoretical parametric design of the achromatic lens will be shown together with a series of simulations to verify the performance of each lens topology. The results will be compared with a standard Fresnel lens to ascertain the validity and effectiveness of the obtained design. Finally, a novel kind of hybrid lens is proposed, which combines the advantages of each type of lens (standard and Fresnel according to the optimal operating region of each design. Efficiency and concentration ratios of each particular lens are shown, regarding lens dimension, light’s incidence angle, or wavelength. Through this innovative achromatic design concentration ratios above 1000 suns, which hardly reach standard Fresnel lenses. Furthermore chromatic dispersion is minimized and the efficiency rate is over 85% of efficiency for a wide spectral range (from 350 nm to 1100 nm.

  5. Study of the soluble lens proteins from different amphibian species

    NARCIS (Netherlands)

    Brahma, S.K.; Doorenmaalen, W.J. van

    1969-01-01

    Soluble lens proteins from five species of amphibia have been studied by zone electrophoresis and other immunochemical methods. Their patterns, as revealed by electrophoresis, do not differ markedly though the numbers of bands and subunits vary. The γ-crystallin appears to be the predominant lens pr

  6. The analysis of optical wave beams propagation in lens systems

    Science.gov (United States)

    Kazakov, I.; Mosentsov, S.; Moskaletz, O.

    2016-08-01

    In this paper some aspects of the formation and propagation of optical wave beams in lens systems were considered. As an example, the two-lens optical information processing system was considered. Analysis of the two-lens optical circuit has been made with a systems approach perspective. As part of the radio-optical analogies had been applied certain provisions of the theory of dynamical systems to the spatial optical system. The lens system is represented as a simple series-connected optical elements with known spatial impulse response. General impulse response of such a system has been received, as well as consider some special cases of the impulse response. The question of the relationship between the parameters and the size of the input aperture lenses for undistorted transmission of the optical signal has been considered. Analysis of the energy loss resulting from the finite aperture of the lens. It's based on an assessment of the fraction of radiation that propagates beyond the lens. Analysis showed that the energy losses depend explicitly on the following parameters: radiation wavelength, distance between input aperture and lens, and ratio of the input aperture and lens aperture. With the computer help simulation the dependence of losses was shown on the above parameters

  7. Bioinspired solid-liquid mixed tunable lens with multilayered structure

    Science.gov (United States)

    Liang, Dan; Wang, Xuan-Yin; Du, Jia-Wei

    2015-06-01

    A solid-liquid mixed tunable lens with multilayered structure is proposed. The designed lens utilizes a solid-state elastic polymer, optical liquid, and glass as the optical medium, and adjusts the focus by changing the surface curvature of the elastic polymer. The integrated structure of the tunable lens is presented, as well as detailed descriptions of the lens materials, fabrication, and assembling process. Images captured through the tunable lens under different displacement loads are presented, and the relationship among the displacement load, curvature radius, and effective focal length is analyzed. Additionally, the optical property of the tunable lens is simulated using the ZEMAX software. A change in focal length from 14.8 mm to 30 mm is demonstrated within the tiny 0.12 mm variation of the displacement load. Numerical analyses show that the lens distortion is less than 2%, and the modulation transfer function reaches 67 line pairs per mm. The solid-liquid mixed tunable lens shows the potential for developing a compact, low-aberration, and stable optical system.

  8. A Broadband Metasurface-Based Terahertz Flat-Lens Array

    KAUST Repository

    Wang, Qiu

    2015-02-12

    A metasurface-based terahertz flat-lens array is proposed, comprising C-shaped split-ring resonators exhibiting locally engineerable phase discontinuities. Possessing a high numerical aperture, the planar lens array is flexible, robust, and shows excellent focusing characteristics in a broadband terahertz frequency. It could be an important step towards the development of planar terahertz focusing devices for practical applications.

  9. Opaque Contact Lens For Tracking Motion Of Eye

    Science.gov (United States)

    Zografos, James L., II; Gibson, Charles R.

    1993-01-01

    Opaque contact lens facilitates measurements of movements of eye; particularly, torsional movements. Lens, marked with pair of indices at diameter of 0.5 mm, provides stable, high-contrast reference for measurements of angular position and velocity of eye by use of video-image-analysis techniques. Intended for use in experiments on response of eye to vestibular balance mechanism.

  10. The "Youth Lens": Analyzing Adolescence/ts in Literary Texts

    Science.gov (United States)

    Petrone, Robert; Sarigianides, Sophia Tatiana; Lewis, Mark A.

    2014-01-01

    Drawing from interdisciplinary scholarship that re-conceptualizes adolescence as a cultural construct, this article introduces a "Youth Lens." A "Youth Lens" comprises an approach to textual analysis that examines how ideas about adolescence and youth get formed, circulated, critiqued, and revised. Focused specifically on its…

  11. The NNEST lens non native english speakers in TESOL

    CERN Document Server

    Mahboob, Ahmar

    2010-01-01

    The NNEST Lens invites you to imagine how the field of TESOL and applied linguistics can develop if we use the multilingual, multicultural, and multinational perspectives of an NNEST lens to re-examine our assumptions, practices, and theories in the field

  12. Isofocusing and immunological investigations on cephalopod lens proteins

    NARCIS (Netherlands)

    Brahma, S.K.; Lancieri, M.

    1979-01-01

    Soluble lens proteins from Octopus vulgaris, Sepia officinalis, and Loligo vulgaris were analyzed by thin-layer isoelectric focusing and compared by various immunochemical methods using antibodies directed against total soluble lens protein antigens from the said three species. The results show clos

  13. 21 CFR 886.1415 - Ophthalmic trial lens frame.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens frame. 886.1415 Section 886.1415 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1415 Ophthalmic trial lens frame....

  14. Terahertz wave tomographic imaging with a Fresnel lens

    Institute of Scientific and Technical Information of China (English)

    S. Wang; X.-C. Zhang

    2003-01-01

    We demonstrate three-dimensional tomographic imaging using a Fresnel lens with broadband terahertz pulses. Objects at various locations along the beam propagation path are uniquely imaged on the same imaging plane using a Fresnel lens with different frequencies of the imaging beam. This procedure allows the reconstruction of an object's tomographic contrast image by assembling the frequency-dependent images.

  15. Lens autofluorescence is not increased at high altitude

    DEFF Research Database (Denmark)

    Kessel, Line; Kofoed, Peter Kristian; Zubieta-Calleja, Gustavo;

    2010-01-01

    PURPOSE: To study the relation between ambient environmental ultraviolet radiation exposure and lens fluorescence. METHODS: Non-invasive lens fluorometry measurements were compared in healthy Bolivian and Danish subjects. Background ultraviolet radiation was 4.5 times higher in Bolivia than in...

  16. Lipid-protein interactions in plasma membranes of fiber cells isolated from the human eye lens.

    Science.gov (United States)

    Raguz, Marija; Mainali, Laxman; O'Brien, William J; Subczynski, Witold K

    2014-03-01

    The protein content in human lens membranes is extremely high, increases with age, and is higher in the nucleus as compared with the cortex, which should strongly affect the organization and properties of the lipid bilayer portion of intact membranes. To assess these effects, the intact cortical and nuclear fiber cell plasma membranes isolated from human lenses from 41- to 60-year-old donors were studied using electron paramagnetic resonance spin-labeling methods. Results were compared with those obtained for lens lipid membranes prepared from total lipid extracts from human eyes of the same age group [Mainali, L., Raguz, M., O'Brien, W. J., and Subczynski, W. K. (2013) Biochim. Biophys. Acta]. Differences were considered to be mainly due to the effect of membrane proteins. The lipid-bilayer portions of intact membranes were significantly less fluid than lipid bilayers of lens lipid membranes, prepared without proteins. The intact membranes were found to contain three distinct lipid environments termed the bulk lipid domain, boundary lipid domain, and trapped lipid domain. However, the cholesterol bilayer domain, which was detected in cortical and nuclear lens lipid membranes, was not detected in intact membranes. The relative amounts of bulk and trapped lipids were evaluated. The amount of lipids in domains uniquely formed due to the presence of membrane proteins was greater in nuclear membranes than in cortical membranes. Thus, it is evident that the rigidity of nuclear membranes is greater than that of cortical membranes. Also the permeability coefficients for oxygen measured in domains of nuclear membranes were significantly lower than appropriate coefficients measured in cortical membranes. Relationships between the organization of lipids into lipid domains in fiber cells plasma membranes and the organization of membrane proteins are discussed.

  17. Dielectric Optical-Controlled Magnifying Lens by Nonlinear Negative Refraction

    CERN Document Server

    Cao, Jianjun; Zheng, Yuanlin; Chen, Xianfeng; Liang, Xiaogan; Wan, Wenjie

    2014-01-01

    A simple optical lens plays an important role for exploring the microscopic world in science and technology by refracting light with tailored spatially varying refractive index. Recent advancements in nanotechnology enable novel lenses, such as, superlens, hyperlens, Luneburg lens, with sub-wavelength resolution capabilities by specially designing materials' refractive indices with meta-materials and transformation optics. However, these artificially nano/micro engineered lenses usually suffer high losses from metals and are highly demanding in fabrication. Here we experimentally demonstrate for the first time a nonlinear dielectric magnifying lens using negative refraction by degenerate four-wave mixing in a plano-concave glass slide, obtaining magnified images. Moreover, we transform a nonlinear flat lens into a magnifying lens by introducing transformation optics into nonlinear regime, achieving an all-optical controllable lensing effect through nonlinear wave mixing, which may have many potential applicat...

  18. Multifunctional metasurface lens for imaging and Fourier transform

    Science.gov (United States)

    Wen, Dandan; Yue, Fuyong; Ardron, Marcus; Chen, Xianzhong

    2016-06-01

    A metasurface can manipulate light in a desirable manner by imparting local and space-variant abrupt phase change. Benefiting from such an unprecedented capability, the conventional concept of what constitutes an optical lens continues to evolve. Ultrathin optical metasurface lenses have been demonstrated based on various nanoantennas such as V-shape structures, nanorods and nanoslits. A single device that can integrate two different types of lenses and polarities is desirable for system integration and device miniaturization. We experimentally demonstrate such an ultrathin metasurface lens that can function either as a spherical lens or a cylindrical lens, depending on the helicity of the incident light. Helicity-controllable focal line and focal point in the real focal plane, as well as imaging and 1D/2D Fourier transforms, are observed on the same lens. Our work provides a unique tool for polarization imaging, image processing and particle trapping.

  19. Status of eye lens radiation dose monitoring in European hospitals

    International Nuclear Information System (INIS)

    A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers. (paper)

  20. Patient acceptability of the Tecnis® multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Sood P

    2011-03-01

    Full Text Available Priyanka Sood1, Maria A Woodward21Emory Eye Center, Atlanta, GA, USA; 2Kellogg Eye Center, Ann Arbor, MI, USAAbstract: Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL designs. The Tecnis® Multifocal Intraocular Lens incorporates an aspheric, modified anterior prolate IOL with a diffractive multifocal lens design. The design aims to minimize spherical aberration and improve range of focus. The purpose of this review is to assess patient acceptability of the Tecnis® multifocal intraocular lens.Keywords: Tecnis®, intraocular lens, multifocal, presbyopia 

  1. Gabor lens focusing of a negative ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Palkovic, J.A.; Mills, F.E.; Schmidt, C.; Young, D.E.

    1989-05-01

    Gabor or plasma lenses have previously been used to focus intense beams of positive ions at energies from 10 keV to 5 MeV. It is the large electrostatic field of the non-neutral plasma in the Gabor lens which is responsible for the focusing. Focusing an ion beam with a given sign of charge in a Gabor lens requires a non-neutral plasma with the opposite sign of charge as the beam. A Gabor lens constructed at Fermilab has been used to focus a 30 keV proton beam with good optical quality. We discuss studies of the action of a Gabor lens on a beam of negative ions. A Gabor lens has been considered for matching an H/sup /minus// beam into an RFQ in the redesign of the low energy section of the Fermilab linac. 9 refs., 3 figs., 1 tab.

  2. Gabor lens focusing of a negative ion beam

    International Nuclear Information System (INIS)

    Gabor or plasma lenses have previously been used to focus intense beams of positive ions at energies from 10 keV to 5 MeV. It is the large electrostatic field of the non-neutral plasma in the Gabor lens which is responsible for the focusing. Focusing an ion beam with a given sign of charge in a Gabor lens requires a non-neutral plasma with the opposite sign of charge as the beam. A Gabor lens constructed at Fermilab has been used to focus a 30 keV proton beam with good optical quality. We discuss studies of the action of a Gabor lens on a beam of negative ions. A Gabor lens has been considered for matching an H/sup /minus// beam into an RFQ in the redesign of the low energy section of the Fermilab linac. 9 refs., 3 figs., 1 tab

  3. Do gravitational lens galaxies have an excess of luminous substructure?

    CERN Document Server

    Nierenberg, A M; Treu, T

    2013-01-01

    Strong gravitational lensing can be used to directly measure the mass function of their satellites, thus testing one of the fundamental predictions of cold dark matter cosmological models. Given the importance of this test it is essential to ensure that galaxies acting as strong lenses have dark and luminous satellites which are representative of the overall galaxy population. We address this issue by measuring the number and spatial distribution of luminous satellites in ACS imaging around lens galaxies from the Sloan Lens Advanced Camera for Surveys (SLACS) lenses, and comparing them with the satellite population in ACS imaging of non lens galaxies selected from COSMOS, which has similar depth and resolution to the ACS images of SLACS lenses. In order to compare the samples of lens and non lens galaxies, which have intrinsically different stellar mass distributions, we measure, for the first time, the number of satellites per host as a continuous function of host stellar mass for both populations. We find t...

  4. Focusing properties of a square electrostatic rainbow lens doublet

    Directory of Open Access Journals (Sweden)

    Telečki Igor N.

    2015-01-01

    Full Text Available This is a study on the properties of a square electrostatic rainbow lens doublet. The said optical element consists of two square electrostatic rainbow lenses with the second lens axially rotated for 45 degrees with respect to the first one. The propagation of a proton beam with a kinetic energy of 10 keV through the doublet is in the focus of our analysis. The potential of the electrodes of both lenses is 2 kV. The electrostatic potential and the electric field components of the lens doublet are calculated using a 3-D computer code based on the method of moments. Spatial and angular distributions of protons propagating through the lens doublet, as well as the parameters defining beam quality, are investigated. As in the case of the single square electrostatic rainbow lens, the evolution of these distributions is determined by the evolution of corresponding rainbow lines, generated by the use of the theory of crystal rainbows. Our study shows that a beam core in the shape of a cusped square is formed by the spatial rainbow line that appears first. This rainbow line occurs during proton propagation through the first lens. The beam core retains the cusped square shape during the propagation through the second lens. The electrostatic field of the second lens causes the appearance of an additional spatial rainbow line, which encompasses the beam core and defines the outer border of the beam. This rainbow line constitutes the main difference between the cases of the lens doublet and a single lens. [Projekat Ministarstva nauke Republike Srbije, br. III45006

  5. Cataract Surgery for Tilted Lens in Peters' Anomaly Type 2

    Directory of Open Access Journals (Sweden)

    Tadayuki Nishide

    2013-09-01

    Full Text Available Background: Cases of cataract surgery without penetrating keratoplasty in patients with Peters' anomaly are very rare. We report a case of Peters' anomaly type 2 with tilted lens due to synechia between the lens and iris that was treated with cataract surgery without penetrating keratoplasty. Case Presentation: A 16-year-old girl had Peters' anomaly in both eyes. Corneal opacity was severe in the left eye due to high-grade dysgenesis of the anterior segment. In the right eye, corneal opacity had spread from the center of the cornea to the inferotemporal side, and there was synechia between the iris and corneal endothelium from the inferonasal side to the inferotemporal side. Opacity was observed in the anterior pole of the lens, and there was synechia between the anterior iris and the lens. Ultrasound biomicroscopy (UBM revealed that the lens was tilted because of synechia. The tilted lens induced astigmatism, which reduced visual acuity to 20/250, in conjunction with a cataract. Cataract surgery was performed; the synechia between the lens capsule and the iris was severed, an intraocular lens was inserted, and the tilt was repaired. UBM was used postoperatively to confirm that the lens capsule synechia had been corrected and that the intraocular lens was not tilted. As a result, visual acuity improved to 20/100; glaucoma and expansion of corneal opacity were not observed. Conclusions: Severing of the synechia between the cataract and iris, during cataract surgery, in a patient with Peters' anomaly type 2 resulted in favorable postoperative visual acuity.

  6. Cosmic Lens Reveals Distant Galactic Violence

    Science.gov (United States)

    2008-10-01

    By cleverly unraveling the workings of a natural cosmic lens, astronomers have gained a rare glimpse of the violent assembly of a young galaxy in the early Universe. Their new picture suggests that the galaxy has collided with another, feeding a supermassive black hole and triggering a tremendous burst of star formation. Gravitational Lens Diagram Imaging a Distant Galaxy Using a Gravitational Lens CREDIT: Bill Saxton, NRAO/AUI/NSF Click on image for details and more graphics. The astronomers used the National Science Foundation's Very Large Array (VLA) radio telescope to look at a galaxy more than 12 billion light-years from Earth, seen as it was when the Universe was only about 15 percent of its current age. Between this galaxy and Earth lies another distant galaxy, so perfectly aligned along the line of sight that its gravity bends the light and radio waves from the farther object into a circle, or "Einstein Ring." This gravitational lens made it possible for the scientists to learn details of the young, distant galaxy that would have been unobtainable otherwise. "Nature provided us with a magnifying glass to peer into the workings of a nascent galaxy, providing an exciting look at the violent, messy process of building galaxies in the early history of the Universe," said Dominik Riechers, who led this project at the Max Planck Institute for Astronomy in Germany and now is a Hubble Fellow at the California Institute of Technology (Caltech). The new picture of the distant galaxy, dubbed PSS J2322+1944, shows a massive reservoir of gas, 16,000 light-years in diameter, that contains the raw material for building new stars. A supermassive black hole is voraciously eating material, and new stars are being born at the rate of nearly 700 Suns per year. By comparison, our Milky Way Galaxy produces the equivalent of about 3-4 Suns per year. The black hole appears to be near the edge, rather than at the center, of the giant gas reservoir, indicating, the astronomers say

  7. The sloan lens acs survey. II. Stellar populations and internal structure of early-type lens galaxies

    NARCIS (Netherlands)

    Treu, Tommaso; Koopmans, Léon V.; Bolton, Adam S.; Burles, Scott; Moustakas, Leonidas A.

    2006-01-01

    We use HST images to derive effective radii and effective surface brightnesses of 15 early-type (E+S0) lens galaxies identified by the SLACS Survey. Our measurements are combined with stellar velocity dispersions from the SDSS database to investigate for the first time the distribution of lens galax

  8. Bacterial transmission from lens storage cases to contact lenses - Effects of lens care solutions and silver impregnation of cases

    NARCIS (Netherlands)

    Vermeltfoort, Pit B. J.; Hooymans, Johanna M. M.; Busscher, Henk J.; van der Mei, Henny C.

    2008-01-01

    The killing efficacies of multipurpose lens care solutions on planktonic and biofilm bacteria grown in polypropylene contact lens storage cases with and without silver impregnation and effects on bacterial transmission from storage cases to silicone hydrogel contact lenses were investigated. For tra

  9. The Sloan Lens ACS Survey. I. A large spectroscopically selected sample of massive early-type lens galaxies

    NARCIS (Netherlands)

    Bolton, AS; Burles, S; Koopmans, LVE; Treu, T; Moustakas, LA

    2006-01-01

    The Sloan Lens ACS (SLACS) Survey is an efficient Hubble Space Telescope (HST) Snapshot imaging survey for new galaxy-scale strong gravitational lenses. The targeted lens candidates are selected spectroscopically from the Sloan Digital Sky Survey (SDSS) database of galaxy spectra for having multiple

  10. Design and analysis of an adaptive lens that mimics the performance of the crystalline lens in the human eye

    Science.gov (United States)

    Santiago-Alvarado, Agustin; Cruz-Félix, Angel S.; Iturbide-Jiménez, F.; Martínez-López, M.; Ramírez-Como, M.; Armengol-Cruz, V.; Vásquez-Báez, I.

    2014-09-01

    Tunable lenses are optical systems that have attracted much attention due to their potential applications in such areas like ophthalmology, machine vision, microscopy and laser processing. In recent years we have been working in the analysis and performance of a liquid-filled variable focal length lens, this is a lens that can modify its focal length by changing the amount of water within it. Nowadays we extend our study to a particular adaptive lens known as solid elastic lens (SEL) that it is formed by an elastic main body made of Polydimethylsiloxane (PDMS Sylgard 184). In this work, we present the design, simulation and analysis of an adaptive solid elastic lens that in principle imitates the accommodation process of the crystalline lens in the human eye. For this work, we have adopted the parameters of the schematic eye model developed in 1985 by Navarro et al.; this model represents the anatomy of the eye as close as possible to reality by predicting an acceptable and accurate quantity of spherical and chromatic aberrations without any shape fitting. An opto-mechanical analysis of the accommodation process of the adaptive lens is presented, by simulating a certain amount of radial force applied onto the SEL using the finite element method with the commercial software SolidWorks®. We also present ray-trace diagrams of the simulated compression process of the adaptive lens using the commercial software OSLO®.

  11. Simultaneous bilensectomy and endothelial keratoplasty for angle-supported phakic intraocular lens-induced corneal decompensation

    Directory of Open Access Journals (Sweden)

    Vikas Mittal

    2011-01-01

    Full Text Available A 40-year-old lady presented with severe endothelial cell loss in both eyes 14 years after angle-supported phakic intraocular lens (AS PIOL implantation. The left eye had severe corneal edema with bullous keratopathy. The right eye had markedly reduced endothelial cell count (655 cells/mm 2 although the cornea was clear. She underwent simultaneous bilensectomy (AS PIOL explantation and phacoemulsification and Descemet′s stripping and endothelial keratoplasty (DSEK in the left eye. Explanted AS PIOL was identified as ZSAL-4 (Morcher, Stuttgart, Germany model. Corneal edema cleared completely in 2 months with a best corrected visual acuity (-2.25 D sph of 20/60. No intervention was done in the right eye. The present case illustrates that AS PIOL-induced endothelial decompensation can be effectively managed by simultaneous bilensectomy and endothelial keratoplasty.

  12. One Clear Image? Challenging Simplicity in Place Branding

    DEFF Research Database (Denmark)

    Ren, Carina Bregnholm; Blichfeldt, Bodil Stilling

    2011-01-01

    Unique selling points! Simplicity sells! One clear identity! One clear image! These are some of the place branding mantras of today. In this paper, this “simplicity trend” is critically examined and challenged by raising the question whether clear images and simplicity are truly the only options...

  13. Analysis of marine stratocumulus clearing events during FIRE

    Science.gov (United States)

    Kloesel, Kevin A.

    1990-01-01

    During FIRE, three major stratocumulus clearing events took place over the project region. These clearing events are analyzed using synoptic variables to determine if these clearing events can be predicted by current modeling techniques. A preliminary statistical evaluation of the correlation between satellite cloud brightness parameters and NMC global model parameters is available in Wylie, et al., 1989.

  14. Intraocular lens employed for cataract surgery

    International Nuclear Information System (INIS)

    The aim of this paper is to illustrate the techniques of cataract surgery with implantation of intraocular lenses and some physical properties of the used materials. The new technology, coupled with extensive experience and the studied cases, permits to increase the standardization and accuracy of the engravings, by reducing the use and handling of surgical instruments inside the eye. At present it is possible to replace the cataract with crystalline lenses based on biopolymers such as PMMA, silicone, acrylic hydrophilic and hydrophobic acrylic. These materials are increasingly able to replace the natural lens and to ensure the fully functional of the eye. The role of femtosecond lasers in cataract surgery, to assist or replace several aspects of the manual cataract surgery, are discussed.

  15. Achromatic Metasurface Lens at Telecommunication Wavelengths.

    Science.gov (United States)

    Khorasaninejad, Mohammadreza; Aieta, Francesco; Kanhaiya, Pritpal; Kats, Mikhail A; Genevet, Patrice; Rousso, David; Capasso, Federico

    2015-08-12

    Nanoscale optical resonators enable a new class of flat optical components called metasurfaces. This approach has been used to demonstrate functionalities such as focusing free of monochromatic aberrations (i.e., spherical and coma), anomalous reflection, and large circular dichroism. Recently, dielectric metasurfaces that compensate the phase dispersion responsible for chromatic aberrations have been demonstrated. Here, we utilize an aperiodic array of coupled dielectric nanoresonators to demonstrate a multiwavelength achromatic lens. The focal length remains unchanged for three wavelengths in the near-infrared region (1300, 1550, and 1800 nm). Experimental results are in agreement with full-wave simulations. Our findings are an essential step toward a realization of broadband flat optical elements. PMID:26168329

  16. Ulcerative keratitis associated with contact lens wear

    Directory of Open Access Journals (Sweden)

    Bharathi M

    2007-01-01

    Full Text Available To review the microbiological profile of ulcerative keratitis associated with contact lens (CL-wear, 35 patients with culture-proven CL-associated microbial keratitis were studied between September 1999 and September 2002. Corneal scrapes and CL-care products were collected and were subjected to microbiological evaluation. Gram-negative bacilli alone were recovered from the corneal scrapes of all 35 (100% patients, all 70 (100% CL storage case wells and also from CL-care solution of six (17.14% of the 35 patients. There was a significantly higher number of Pseudomonas aeruginosa (71.43% isolated from eyes with CL-related keratitis than other bacterial isolates (28.57% ( P < 0.001. Microbial contamination of CL storage cases was a great risk for gram-negative bacterial infection among soft CL-wearers.

  17. The correction of electron lens aberrations.

    Science.gov (United States)

    Hawkes, P W

    2015-09-01

    The progress of electron lens aberration correction from about 1990 onwards is chronicled. Reasonably complete lists of publications on this and related topics are appended. A present for Max Haider and Ondrej Krivanek in the year of their 65th birthdays. By a happy coincidence, this review was completed in the year that both Max Haider and Ondrej Krivanek reached the age of 65. It is a pleasure to dedicate it to the two leading actors in the saga of aberration corrector design and construction. They would both wish to associate their colleagues with such a tribute but it is the names of Haider and Krivanek (not forgetting Joachim Zach) that will remain in the annals of electron optics, next to that of Harald Rose. I am proud to know that both regard me as a friend as well as a colleague. PMID:26025209

  18. Motherhood transition through an existential lens

    DEFF Research Database (Denmark)

    Prinds, Christina Lange

    2015-01-01

    existentially among Danish first-time mothers, and whether they differ among mothers of full-term children (FT) and mothers of preterm children (PT). The thesis consists of three individual, still interrelated papers, first a scoping review among mothers having given birth at full term, identifying existing...... research about the significance of motherhood transition through the lens of existential psychology. For the second and third study, a nationwide questionnaire survey among Danish first-time FT and PT mothers was conducted. In the second study attitudes about making meaning of life existentially...... was explored, and in the third study prayer and/or meditation practices were explored. Through the analyses of the included interview studies in the first study, we suggest that motherhood transition is considered a pivotal yet paradoxical life event both bodily, psychologically, s-cially and existentially...

  19. Quantum Weighted Projective and Lens Spaces

    Science.gov (United States)

    D'Andrea, Francesco; Landi, Giovanni

    2015-11-01

    We generalize to quantum weighted projective spaces in any dimension previous results of us on K-theory and K-homology of quantum projective spaces `tout court'. For a class of such spaces, we explicitly construct families of Fredholm modules, both bounded and unbounded (that is, spectral triples), and prove that they are linearly independent in the K-homology of the corresponding C *-algebra. We also show that the quantum weighted projective spaces are base spaces of quantum principal circle bundles whose total spaces are quantum lens spaces. We construct finitely generated projective modules associated with the principal bundles and pair them with the Fredholm modules, thus proving their non-triviality.

  20. Achromatic Metasurface Lens at Telecommunication Wavelengths.

    Science.gov (United States)

    Khorasaninejad, Mohammadreza; Aieta, Francesco; Kanhaiya, Pritpal; Kats, Mikhail A; Genevet, Patrice; Rousso, David; Capasso, Federico

    2015-08-12

    Nanoscale optical resonators enable a new class of flat optical components called metasurfaces. This approach has been used to demonstrate functionalities such as focusing free of monochromatic aberrations (i.e., spherical and coma), anomalous reflection, and large circular dichroism. Recently, dielectric metasurfaces that compensate the phase dispersion responsible for chromatic aberrations have been demonstrated. Here, we utilize an aperiodic array of coupled dielectric nanoresonators to demonstrate a multiwavelength achromatic lens. The focal length remains unchanged for three wavelengths in the near-infrared region (1300, 1550, and 1800 nm). Experimental results are in agreement with full-wave simulations. Our findings are an essential step toward a realization of broadband flat optical elements.

  1. CERN through the lens of Peter Ginter

    CERN Multimedia

    2008-01-01

    This summer, passers-by along the Quai Wilson on the banks of Lake Geneva will be able to enjoy an unusual exhibition of photographs devoted to CERN and the LHC. Fifty images from the work of Peter Ginter, organized into themes, give strollers on the Quai Wilson a glimpse of the unique human and scientific adventure at CERN. An exhibition panel, showing a scientist against the background of ALICE’s huge red electromagnet.CERN will reach an important milestone in 2008 with the start-up of the LHC, opening a new window on our Universe for physicists around the world. To celebrate this event with the people who live around Lake Geneva and visitors to the area, CERN and the city of Geneva are jointly putting on the photography exhibition "CERN through the lens of Peter Ginter", which opens on 29 May. A group of some fifty images taken by the German photo...

  2. Hyperbolic metamaterial lens with hydrodynamic nonlocal response

    DEFF Research Database (Denmark)

    Yan, Wei; Mortensen, N. Asger; Wubs, Martijn

    2013-01-01

    We investigate the effects of hydrodynamic nonlocal response in hyperbolic metamaterials (HMMs), focusing on the experimentally realizable parameter regime where unit cells are much smaller than an optical wavelength but much larger than the wavelengths of the longitudinal pressure waves of the f......We investigate the effects of hydrodynamic nonlocal response in hyperbolic metamaterials (HMMs), focusing on the experimentally realizable parameter regime where unit cells are much smaller than an optical wavelength but much larger than the wavelengths of the longitudinal pressure waves...... in the local-response approximation and in the hydrodynamic Drude model can differ considerably. In particular, the optimal frequency for imaging in the nonlocal theory is blueshifted with respect to that in the local theory. Thus, to detect whether nonlocal response is at work in a hyperbolic metamaterial, we...... propose to measure the near-field distribution of a hyperbolic metamaterial lens....

  3. Actual Stationary State for Plasma Lens

    CERN Document Server

    Zadorozhny, Vladimir F; Parsa, Zohreh

    2005-01-01

    The electrostatic plasma lens (PL) provides an attractive and unique tool for manipulating high-current heavy ion beams. The fundamental concept of the PL is based on the use of magnetically insulated electrons and equipotentialization of magnetic field lines. Rigorous application of PL is, however, limited. The reason is the estimation behaviour of electrons for complicated magnetic fields runs into severe difficults.We show that there are specific conditions that admit steady-state of a longitudinal motion, and consider a question of it stability. These results are needed to develop an optimized PL with minimal spherical aberation, in party by optimization of the magnetic field conficuration in the low-magnetic-field range.

  4. Intraocular lens employed for cataract surgery

    Science.gov (United States)

    Roszkowska, A. M.; Torrisi, L.

    2014-04-01

    The aim of this paper is to illustrate the techniques of cataract surgery with implantation of intraocular lenses and some physical properties of the used materials. The new technology, coupled with extensive experience and the studied cases, permits to increase the standardization and accuracy of the engravings, by reducing the use and handling of surgical instruments inside the eye. At present it is possible to replace the cataract with crystalline lenses based on biopolymers such as PMMA, silicone, acrylic hydrophilic and hydrophobic acrylic. These materials are increasingly able to replace the natural lens and to ensure the fully functional of the eye. The role of femtosecond lasers in cataract surgery, to assist or replace several aspects of the manual cataract surgery, are discussed.

  5. Gene expression profile of renal cell carcinoma clear cell type

    Directory of Open Access Journals (Sweden)

    Marcos F. Dall’Oglio

    2010-08-01

    Full Text Available PURPOSE: The determination of prognosis in patients with renal cell carcinoma (RCC is based, classically, on stage and histopathological aspects. The metastatic disease develops in one third of patients after surgery, even in localized tumors. There are few options for treating those patients, and even the new target designed drugs have shown low rates of success in controlling disease progression. Few studies used high throughput genomic analysis in renal cell carcinoma for determination of prognosis. This study is focused on the identification of gene expression signatures in tissues of low-risk, high-risk and metastatic RCC clear cell type (RCC-CCT. MATERIALS AND METHODS: We analyzed the expression of approximately 55,000 distinct transcripts using the Whole Genome microarray platform hybridized with RNA extracted from 19 patients submitted to surgery to treat RCC-CCT with different clinical outcomes. They were divided into three groups (1 low risk, characterized by pT1, Fuhrman grade 1 or 2, no microvascular invasion RCC; (2 high risk, pT2-3, Fuhrman grade 3 or 4 with, necrosis and microvascular invasion present and (3 metastatic RCC-CCT. Normal renal tissue was used as control. RESULTS: After comparison of differentially expressed genes among low-risk, high-risk and metastatic groups, we identified a group of common genes characterizing metastatic disease. Among them Interleukin-8 and Heat shock protein 70 were over-expressed in metastasis and validated by real-time polymerase chain reaction. CONCLUSION: These findings can be used as a starting point to generate molecular markers of RCC-CCT as well as a target for the development of innovative therapies.

  6. Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2013-04-01

    Full Text Available PURPOSE: To evaluate distance and near contrast sensitivity (CS under photopic and mesopic conditions before and after refractive lens exchange (RLE and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model intraocular lens (IOL. METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively were measured before and 6 months postoperatively. Monocular CS function was measured at three different luminance levels (85, 5 and 2.5 cd/m² before and after RLE. Post-implantation results at 6 months were compared with those found before surgery. RESULTS: Our results revealed that patients in both groups obtained good UCVA and BCVA after RLE at distance and near vision in relation to pre-surgery values. No statistically significant differences were found between the values of CS pre and post-RLE at distance and near, at any lighting condition and spatial frequency (p>0.002. CONCLUSIONS: Refractive lens exchange with aspheric AcrySof ReSTOR IOL in myopic and hyperopic population provided good visual function and yield good distance and near CS under photopic and mesopic conditions.

  7. Spectral analysis and comparison of mineral deposits forming in opacified intraocular lens and senile cataractous lens

    Science.gov (United States)

    Lin, Shan-Yang; Chen, Ko-Hwa; Lin, Chih-Cheng; Cheng, Wen-Ting; Li, Mei-Jane

    2010-10-01

    This preliminary report was attempted to compare the chemical components of mineral deposits on the surfaces of an opacified intraocular lens (IOL) and a calcified senile cataractous lens (SCL) by vibrational spectral diagnosis. An opacified intraocular lens (IOL) was obtained from a 65-year-old male patient who had a significant decrease in visual acuity 2-years after an ocular IOL implantation. Another SCL with grayish white calcified plaque on the subcapsular cortex was isolated from a 79-year-old male patient with complicated cataract after cataract surgery. Optical light microscope was used to observe both samples and gross pictures were taken. Fourier transform infrared (FT-IR) and Raman microspectroscopic techniques were employed to analyze the calcified deposits. The curve-fitting algorithm using the Gaussian function was also used to quantitatively estimate the chemical components in each deposit. The preliminary results of spectral diagnosis indicate that the opacified IOL mainly consisted of the poorly crystalline, immature non-stoichiometric hydroxyapatite (HA) with higher content of type B carbonated apatites. However, the calcified plaque deposited on the SCL was comprised of a mature crystalline stoichiometric HA having higher contents of type A and type B carbonate apatites. More case studies should be examined in future.

  8. Aspherical Lens Design Using Genetic Algorithm for Reducing Aberrations in Multifocal Artificial Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Chih-Ta Yen

    2015-09-01

    Full Text Available A complex intraocular lens (IOL design involving numerous uncertain variables is proposed. We integrated a genetic algorithm (GA with the commercial optical design software of (CODE V to design a multifocal IOL for the human eye. We mainly used an aspherical lens in the initial state to the crystalline type; therefore, we used the internal human eye model in the software. The proposed optimized algorithm employs a GA method for optimally simulating the focusing function of the human eye; in this method, the thickness and curvature of the anterior lens and the posterior part of the IOL were varied. A comparison of the proposed GA-designed IOLs and those designed using a CODE V built-in optimal algorithm for 550 degrees myopia and 175 degrees astigmatism conditions of the human eye for pupil size 6 mm showed that the proposed IOL design improved the spot size of root mean square (RMS, tangential coma (TCO and modulation transfer function (MTF at a spatial frequency of 30 with a pupil size of 6 mm by approximately 17%, 43% and 35%, respectively. However, the worst performance of spherical aberration (SA was lower than 46%, because the optical design involves a tradeoff between all aberrations. Compared with the traditional CODE V built-in optimal scheme, the proposed IOL design can efficiently improve the critical parameters, namely TCO, RMS, and MTF.

  9. Solar lens mission concept for interstellar exploration

    Science.gov (United States)

    Brashears, Travis; Lubin, Philip; Turyshev, Slava; Shao, Michael; Zhang, Qicheng

    2015-09-01

    The long standing approach to space travel has been to incorporate massive on-board electronics, probes and propellants to achieve space exploration. This approach has led to many great achievements in science, but will never help to explore the interstellar medium. Fortunately, a paradigm shift is upon us in how a spacecraft is constructed and propelled. This paper describes a mission concept to get to our Sun's Gravity Lens at 550AU in less than 10 years. It will be done by using DE-STAR, a scalable solar-powered phased-array laser in Earth Orbit, as a directed energy photon drive of low-mass wafersats. [1] [2] [3] [4] [5] With recent technologies a complete mission can be placed on a wafer including, power from an embedded radio nuclear thermal generator (RTG), PV, laser communications, imaging, photon thrusters for attitude control and other sensors. As one example, a futuristic 200 MW laser array consisting of 1 - 10 kw meter scale sub elements with a 100m baseline can propel a 10 gram wafer scale spacecraft with a 3m laser sail to 60AU/Year. Directed energy propulsion of low-mass spacecraft gives us an opportunity to capture images of Alpha Centauri and its planets, detailed imaging of the cosmic microwave background, set up interstellar communications by using gravity lenses around nearby stars to boost signals from interstellar probes, and much more. This system offers a very large range of missions allowing hundreds of wafer scale payload launches per day to reach this cosmological data reservoir. Directed Energy Propulsion is the only current technology that can provide a near-term path to utilize our Sun's Gravity Lens.

  10. Conduta cirúrgica na subluxação do cristalino Surgical approach to the subluxated lens

    Directory of Open Access Journals (Sweden)

    Nórton Souto Severo

    2004-02-01

    Full Text Available OBJETIVO: Apresentar 10 casos de subluxação de cristalino, secundários a trauma ou a síndrome de Marfan, discutindo o tratamento e os resultados obtidos. MÉTODOS: Foram estudados 10 olhos de 9 pacientes, 6 casos secundários a trauma contuso e 4 casos a síndrome de Marfan. A idade média foi de 48,9 ± 18,2 anos, com tempo de seguimento de 34,6 ± 11,6 meses (12 a 62 meses. Os pacientes foram submetidos à facectomia intracapsular (1 caso, extracapsular com capsulorrexe (1 caso, facoemulsificação sem LIO (1 caso, e facoemulsificação com implante de LIO (7 casos. Anéis expansores capsulares foram utilizados em 7 olhos. RESULTADOS: Houve melhora da acuidade visual em todos os casos durante o seguimento, exceto em um, em que houve descolamento de retina, 20 dias após o procedimento. CONCLUSÃO: A facectomia com implante de LIO em pacientes com cristalino subluxado é procedimento viável, principalmente com a facoemulsificação e o uso do anel expansor capsular, podendo melhorar bastante a acuidade visual e a qualidade de vida desses pacientes.PURPOSE: To evaluate 10 cases of subluxated lens due to trauma or Marfan syndrome, focussing on their treatment and the results. METHODS: Ten eyes of 9 patients were operated on due to lens subluxation. Six eyes were due to trauma and 4 eyes to Marfan syndrome. The mean age was 48.9 ± 18.2 years, and the follow-up period of 34.6 ± 11.6 months. Patients were submitted to intracapsular lens extraction (1 eye, extracapsular lens extraction (1 eye, phacoemulsification without IOL (1 eye, and phacoemulsification with IOL (7 eyes. Endocapsular rings were used in 7 eyes. RESULTS: Best-corrected visual acuity improved in all patients, except for one, who had a regmatogeneous retinal detachment, 20 days after surgery. CONCLUSION: Lens extraction with IOL implantation in subluxated lens patients has a good prognosis, especially with pha-coemulsification and endocapsular rings. With this approach, we were

  11. LASL lens design procedure: simple, fast, precise, versatile

    Energy Technology Data Exchange (ETDEWEB)

    Brixner, B.

    1978-11-01

    The Los Alamos Scientific Laboratory general-purpose lens design procedure optimizes specific lens prescriptions to obtain the smallest possible image spots and therefore near-spherical wave fronts of light converging on all images in the field of view. Optical image errors are analyzed in much the same way that they are measured on the optical bench. This lens design method is made possible by using the full capabilities of large electronic computers. First, the performance of the whole lens is sampled with many precisely traced skew rays. Next, lens performance is analyzed with spot diagrams generated by the many rays. Third, lens performance is optimized with a least squares system aimed at reducing all image errors to zero. This statistical approach to lens design uses skew rays and precisely measured ray deviations from ideal image points to achieve greater accuracy than was possible with the classical procedure, which is based on approximate expressions derived from simplified ray traces developed for pencil-and-paper calculations.

  12. Lens dislocation has a possible relationship with laser iridotomy

    Directory of Open Access Journals (Sweden)

    Mutoh T

    2012-12-01

    Full Text Available Tetsuya Mutoh,1,2 Kevin F Barrette,2 Yukihiro Matsumoto,1 Makoto Chikuda11Department of Ophthalmology, Dokkyo Medical University Koshigaya Hospital, Koshigaya City, Saitama, Japan; 2Department of Ophthalmology, Boston University School of Medicine, Boston, MA, USAAbstract: We report our recent experience of four eyes with spontaneous lens dislocation in four patients with no history of trauma or any systemic disease associated with zonular dialysis. Lens dislocation developed with 0.5 to 6 months following laser iridotomy. All patients were male and two eyes were complicated with acute primary angle closure glaucoma preoperatively. Case 1 showed bilateral lens dislocation, while cases 2 and 3 involved unilateral lens dislocation. Cases 2 and 3 showed lenses completely dislocated into the vitreous cavity. All cases needed lens removal and scleral fixation of intraocular lenses. Final visual acuity was 1.2 in all cases. We suspect that laser iridotomy may induce localized zonular dialysis that results in progressive zonular weakness, leading to lens dislocation.Keywords: lens dislocation, laser iridotomy, primary angle closure glaucoma

  13. Challenges of using dielectric elastomer actuators to tune liquid lens

    Science.gov (United States)

    Keong, Gih-Keong; La, Thanh-Giang; Shiau, Li-Lynn; Tan, Adrian W. Y.

    2014-03-01

    Recently, dielectric elastomer actuators (DEAs) have been adopted to tune liquid membrane lens, just like ciliary muscles do to the lens in human eye. However, it faces some challenges, such as high stress, membrane puncture, high driving voltage requirement, and limited focus distance (not more than 707cm), that limit its practical use. The design problem gets more complex as the liquid lens shares the same elastomeric membrane as the DEA. To address these challenges, we separate DEA from the lens membrane. Instead, a liquid-immersed DEA, which is safe from terminal failure, is used as a diaphragm pump to inflate or deflate the liquid lens by hydraulic pressure. This opens up the possibility that the DEA can be thinned down and stacked up to reduce the driving voltage, independent of the lens membrane thickness. Preliminary study showed that our 8-mm-diameter tunable lens can focus objects in the range of 15cm to 50cm with a small driving voltage of 1.8kV. Further miniaturization of DEA could achieve a driving voltage less than 1kV.

  14. Numerical implementation of generalized Coddington equations for ophthalmic lens design

    Science.gov (United States)

    Rojo, P.; Royo, S.; Ramírez, J.; Madariaga, I.

    2014-02-01

    A method for general implementation in any software platform of the generalized Coddington equations is presented, developed, and validated within a Matlab environment. The ophthalmic lens design strategy is presented thoroughly, and the basic concepts of generalized ray tracing are introduced. The methodology for ray tracing is shown to include two inter-related processes. Firstly, finite ray tracing is used to provide the main direction of propagation of the considered ray at the incidence point of interest. Afterwards, generalized ray tracing provides the principal curvatures of the local wavefront at that point, and its orientation after being refracted by the lens. The curvature values of the local wavefront are interpreted as the sagital and tangential powers of the lens at the point of interest. The proposed approach is validated using a double-check of the calculated lens performance in the spherical lens case: while finite ray tracing is validated using a commercial ray tracing software, generalized ray tracing is validated using a software application for ophthalmic lens design based on the classical version of Coddington equations. Equations of the complete tracing process are developed in detail for the case of generic astigmatic ophthalmic lenses as an example. Three-dimensional representation of the sagital and tangential powers of the ophthalmic lens at all directions of gaze then becomes possible, and results are presented for lenses with different geometries.

  15. c-Myc regulates cell proliferation during lens development.

    Directory of Open Access Journals (Sweden)

    Gabriel R Cavalheiro

    Full Text Available Myc protooncogenes play important roles in the regulation of cell proliferation, growth, differentiation and survival during development. In various developing organs, c-myc has been shown to control the expression of cell cycle regulators and its misregulated expression is detected in many human tumors. Here, we show that c-myc gene (Myc is highly expressed in developing mouse lens. Targeted deletion of c-myc gene from head surface ectoderm dramatically impaired ocular organogenesis, resulting in severe microphtalmia, defective anterior segment development, formation of a lens stalk and/or aphakia. In particular, lenses lacking c-myc presented thinner epithelial cell layer and growth impairment that was detectable soon after its inactivation. Defective development of c-myc-null lens was not caused by increased cell death of lens progenitor cells. Instead, c-myc loss reduced cell proliferation, what was associated with an ectopic expression of Prox1 and p27(Kip1 proteins within epithelial cells. Interestingly, a sharp decrease in the expression of the forkhead box transcription factor Foxe3 was also observed following c-myc inactivation. These data represent the first description of the physiological roles played by a Myc family member in mouse lens development. Our findings support the conclusion that c-myc regulates the proliferation of lens epithelial cells in vivo and may, directly or indirectly, modulate the expression of classical cell cycle regulators in developing mouse lens.

  16. Critical Assessment of Correction Methods for Fisheye Lens Distortion

    Science.gov (United States)

    Liu, Y.; Tian, C.; Huang, Y.

    2016-06-01

    A fisheye lens is widely used to create a wide panoramic or hemispherical image. It is an ultra wide-angle lens that produces strong visual distortion. The distortion modeling and estimation of the fisheye lens are the crucial step for fisheye lens calibration and image rectification in computer vision and close-range photography. There are two kinds of distortion: radial and tangential distortion. Radial distortion is large for fisheye imaging and critical for the subsequent image processing. Although many researchers have developed calibration algorithms of radial distortion of fisheye lens, quantitative evaluation of the correction performance has remained a challenge. This is the first paper that intuitively and objectively evaluates the performance of five different calibration algorithms. Upto- date research on fisheye lens calibration is comprehensively reviewed to identify the research need. To differentiate their performance in terms of precision and ease-using, five methods are then tested using a diverse set of actual images of the checkerboard that are taken at Wuhan University, China under varying lighting conditions, shadows, and shooting angles. The method of rational function model, which was generally used for wide-angle lens correction, outperforms the other methods. However, the one parameter division model is easy for practical use without compromising too much the precision. The reason is that it depends on the linear structure in the image and requires no preceding calibration. It is a tradeoff between correction precision and ease-using. By critically assessing the strengths and limitations of the existing algorithms, the paper provides valuable insight and guideline for future practice and algorithm development that are important for fisheye lens calibration. It is promising for the optimal design of lens correction models that are suitable for the millions of portable imaging devices.

  17. Effects of x-irradiation on lens reducing systems. [Rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Giblin, F.J.; Chakrapani, B.; Reddy, V.N.

    1978-01-01

    Studies have been made of the effects of x ray on various lens reducing systems including the levels of NADPH and glutathione (GSH), the activity of the hexose monophosphate shunt (HMS), and the activities of certain enzymes including glutathion reductase, glutathione peroxidase, and glucose-6-phosphate dehydrogenase (G-6-PD). It was found that during several weeks following x irradiation but prior to cataract formation there was very little change in the number of reduced -SH groups per unit weight of lens protein but that, with the appearance of cataract, there was a sudden loss of protein -SH groups. In contrast, the concentration of GSH in the x-rayed lens decreased throughout the experimental period. Similarly, the concentration of NADPH in the x-rayed lens was found to decrease significantly relative to controls one week prior to cataract formation and the ratio of NADPH to NADP/sup +/ in the lens shifted at this time period from a value greater than 1.0 in the control lens to less than 1.0 in the x-rayed lens. A corresponding decrease occurred in the activity of the HMS in x-rayed lenses as measured by culture in the presence of 1-/sup 14/C-labelled glucose. G-6-PD was partially inactivated in the x-rayed lens. Of the eight enzymes studied, G-6-PD appeared to be the most sensitive to x-irradiation. The data indicate that x-irradiation results in a steady decrease in the effectiveness of lens reducing systems and that, when these systems reach a critically low point, sudden oxidation of protein -SH groups and formation of high molecular weight protein aggregates may be initiated.

  18. Evolutionary algorithm for optimization of nonimaging Fresnel lens geometry.

    Science.gov (United States)

    Yamada, N; Nishikawa, T

    2010-06-21

    In this study, an evolutionary algorithm (EA), which consists of genetic and immune algorithms, is introduced to design the optical geometry of a nonimaging Fresnel lens; this lens generates the uniform flux concentration required for a photovoltaic cell. Herein, a design procedure that incorporates a ray-tracing technique in the EA is described, and the validity of the design is demonstrated. The results show that the EA automatically generated a unique geometry of the Fresnel lens; the use of this geometry resulted in better uniform flux concentration with high optical efficiency.

  19. Comparison of shape recovery ratios in various intraocular lens haptics.

    Science.gov (United States)

    Kimura, W; Kimura, T; Sawada, T; Kikuchi, T; Toda, H; Yamada, Y; Nagai, H

    1992-11-01

    Since understanding the mechanical properties of intraocular lens (IOL) haptic materials can minimize decentration after surgery, we have examined shape recovery ratios of various intraocular lens haptics (polypropylene [PP], polyvinylidene fluoride [PVDF], extruded poly(methyl methacrylate) [PMMA]) currently on the market under conditions that approximate clinical use. The results using various Ascon lens-holding forceps and compression tests, during which the lenses were held in a cylindrical holder for seven days, one month, and three months, indicated that PVDF haptics had better shape recovery capability than PP and extruded three-piece PMMA haptics.

  20. Multiplexing schemes for an achromatic programmable diffractive lens

    Energy Technology Data Exchange (ETDEWEB)

    Millan, M S; Perez-Cabre, E; Oton, J [Technical University of Catalonia, Dep. Optics and Optometry, Terrassa-Barcelona, 08222 (Spain)], E-mail: millan@oo.upc.edu

    2008-11-01

    A multiplexed programmable diffractive lens, displayed on a pixelated liquid crystal device under broadband illumination, is proposed to compensate for the severe chromatic aberration that affects diffractive elements. The proposed lens is based on multiplexing a set of sublenses with a common focal length for different wavelengths. We consider different types of integration of the optical information (spatial only, temporal only and hybrid spatial-temporal) combined with a proper selection of the spectral bandwidth. The properties and limits of the achromatic programmable multiplexed lens are described. Experimental results are presented and discussed.

  1. Research of the long-focus Maksutov telephoto lens

    Science.gov (United States)

    Tarasov, I. P.; Tsyganok, E. A.

    2016-04-01

    The article presents the research result and the optical design of long-focus telephoto lens for photo shooting by the academician Maksutov's scheme. It shows a review of lenses for photo shooting on the market today, and also an analysis of the correctional possibilities which is based on the scheme is presented; studied long-focus telephoto lens is compared with its closest analog, the calculation of a new telephoto lens with higher image quality is made on the basis of that comparison.

  2. Vortexlike Power Flow at the Interfaces of Metamaterial Lens

    Directory of Open Access Journals (Sweden)

    K. Fang

    2012-08-01

    Full Text Available The metamaterial lens with DPS/DNS/DPS structure has been realized by using the two-dimensional (2D isotropic transmission line approach. We studied the vortexlike power flow at the interfaces of metamaterial lens and validated by the finite-difference time-domain (FDTD simulator. The computational results showing its different conditions near DPS/DNS and other kinds of interfaces are obtained by CST STUDIO SUITE at different frequencies, and demonstrate the intuitionistic power location at the metamaterial lens interfaces.

  3. Additive manufacturing of a trifocal diffractive-refractive lens

    Science.gov (United States)

    Hinze, Ulf; El-Tamer, Ayman; Doskolovich, Leonid L.; Bezus, Evgeni A.; Reiß, Stefan; Stolz, Heinrich; Guthoff, Rudolf F.; Stachs, Oliver; Chichkov, Boris

    2016-08-01

    The application of two-photon polymerization and molding for the fabrication of a multifocal diffractive-refractive lens operating in water is studied. The fabricated lens is of aspheric shape and combines diffractive and refractive parts in a single element to generate three foci. The lens performance is characterized by visualization of the beam propagation in a transparent basin filled with water containing fluorescein. The experimental measurements are in good agreement with the theoretical description. The obtained results are promising for the realization of trifocal intraocular lenses with predetermined light intensity distribution between the foci.

  4. Development of a universal toric intraocular lens calculator

    Science.gov (United States)

    Hjelmstad, David; Sayegh, Samir I.

    2014-02-01

    We present a method for calculating the ideal toric lens to implant in astigmatic patients following cataract surgery. We show that the online calculators provided by major toric IOL manufacturers are insufficient for both theoretical and practical reasons. We reveal important theoretical shortcomings in their approach, illustrated by a number of cases which demonstrate how the approach can lead to errors in lens selection. Our approach combines the spherical and cylindrical power calculations into one, and allows for lens data from any manufacturer to be used, eliminating the reliance on multiple programs.

  5. Outcomes of Lensectomy in Hereditary Lens Subluxation

    Directory of Open Access Journals (Sweden)

    Mohammad-Hossein Dehghan

    2008-12-01

    Full Text Available

    PURPOSE: To evaluate the results of pars plana lensectomy in patients with hereditary lens subluxation. METHOD: Hospital records of patients with hereditary lens subluxation who had undergone pars plana lensectomy at Labbafinejad Medical Center, Tehran-Iran from 1996 to 2003 were reviewed. Patients with more than 6 months of follow up were included. Underlying disorders, best corrected visual acuity (BCVA before and after surgery, intraocular pressure (IOP, postoperative refraction and complications were evaluated. RESULTS: Overall, records of 87 eyes of 49 patients including 27 male and 22 female subjects were reviewed. Mean follow up duration was 20±18 months. Underlying disorders leading to lens subluxation included Marfan syndrome (79.5%, Weill-Marchesani syndrome (8.2%, simple ectopia lentis (8.2%, and homocystinuria (4.1%. The most common indication for surgery was non-correctable refractive error (92.1%. Mean BCVA was 1.13 LogMAR (20/250 preoperatively, which improved to 0.26 LogMAR (20/30-20/40 postoperatively (P < 0.001. BCVA better than 20/40 was achieved in 82.8% of cases after surgery. Angle-supported anterior chamber intraocular lens (ACIOL was implanted in

  6. Optimized optical clearing method for imaging central nervous system

    Science.gov (United States)

    Yu, Tingting; Qi, Yisong; Gong, Hui; Luo, Qingming; Zhu, Dan

    2015-03-01

    The development of various optical clearing methods provides a great potential for imaging entire central nervous system by combining with multiple-labelling and microscopic imaging techniques. These methods had made certain clearing contributions with respective weaknesses, including tissue deformation, fluorescence quenching, execution complexity and antibody penetration limitation that makes immunostaining of tissue blocks difficult. The passive clarity technique (PACT) bypasses those problems and clears the samples with simple implementation, excellent transparency with fine fluorescence retention, but the passive tissue clearing method needs too long time. In this study, we not only accelerate the clearing speed of brain blocks but also preserve GFP fluorescence well by screening an optimal clearing temperature. The selection of proper temperature will make PACT more applicable, which evidently broaden the application range of this method.

  7. Design and development of a laminated Fresnel lens for point-focus PV systems. Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Hodge, R.C.

    1982-12-01

    A laminated glass-plastic lens parquet using injection molded point focus Fresnel lenses is described. The second phase of a program aimed at investigating the cost effectiveness of a glass-plastic concentrator lens assembly is reported. The first phase dealt with the development of a first generation lens design, the selection of the preferred glass coverplate and glass-to-lens adhesive and initial injection molding lens molding trials. The second phase has dealt with the development of an improved lens design, a full size parquet lamination process, and a second group of injection molding lens molding trials.

  8. Intraocular lens exchange for high myopia in pseudophakic children.

    Science.gov (United States)

    Kraus, C L; Trivedi, R H; Wilson, M E

    2016-09-01

    PurposeThe purpose of this study was to examine the preoperative factors and postoperative outcomes following intraocular lens (IOL) exchange for high myopia in pseudophakic children.MethodsThe medical records of all patients undergoing IOL exchange for high myopia were retrospectively reviewed.ResultsA total of 15 eyes were identified that had undergone an IOL exchange for myopic shift. Average age of cataract extraction (CE) was 5.4 months. In all, 10/15 had a unilateral cataract. IOL exchange usually occurred at an average of 6 years following cataract surgery. The average spherical equivalent (SE) of the refractive error at that time was -9.6 D. Following IOL exchange, SE was -1.3 D. A two-line reduction in best-corrected visual acuity was observed in 1/13 of our patients for whom pre- and post-exchange data were available. The average axial length (AL) of the eye undergoing the IOL exchange was 24.0 mm, average AL in the non-operative eye was 22.1 mm. On average, the operative eyes grew 4.4 mm and the non-operative eyes 3.02 mm. No adverse events were seen in the operative eyes.ConclusionYounger age at the time of CE creates a greater likelihood of AL elongation and predisposes a child to myopic shift. IOL exchange should be considered an option to reduce anisometropia and associated aniseikonia to improve visual outcomes. Successful visual rehabilitation and predictable post-exchange refractions were seen with our patients.

  9. Production and perception of clear speech in Croatian and English

    Science.gov (United States)

    Smiljanić, Rajka; Bradlow, Ann R.

    2005-09-01

    Previous research has established that naturally produced English clear speech is more intelligible than English conversational speech. The major goal of this paper was to establish the presence of the clear speech effect in production and perception of a language other than English, namely Croatian. A systematic investigation of the conversational-to-clear speech transformations across languages with different phonological properties (e.g., large versus small vowel inventory) can provide a window into the interaction of general auditory-perceptual and phonological, structural factors that contribute to the high intelligibility of clear speech. The results of this study showed that naturally produced clear speech is a distinct, listener-oriented, intelligibility-enhancing mode of speech production in both languages. Furthermore, the acoustic-phonetic features of the conversational-to-clear speech transformation revealed cross-language similarities in clear speech production strategies. In both languages, talkers exhibited a decrease in speaking rate and an increase in pitch range, as well as an expansion of the vowel space. Notably, the findings of this study showed equivalent vowel space expansion in English and Croatian clear speech, despite the difference in vowel inventory size across the two languages, suggesting that the extent of vowel contrast enhancement in hyperarticulated clear speech is independent of vowel inventory size.

  10. 600 Volt Stretched Lens Array for Solar Electric Propulsion Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Over the past six years, ENTECH, Auburn, NASA, and other organizations have developed a new space photovoltaic array called the Stretched Lens Array (SLA), which...

  11. Tunable Focus Liquid Lens with Radial-Patterned Electrode

    Directory of Open Access Journals (Sweden)

    Miao Xu

    2015-08-01

    Full Text Available A dielectric liquid lens is prepared based on our previous work. By optimizing the device structure, the liquid lens presents a converging focus with good resolution and changes its focal length over a broad range with a low driving voltage. For a liquid lens with ~2.3 mm diameter in the relaxed state, it can resolve ~40 lp/mm. The resolution does not degrade during focus change. Its focal length can be varied from ~12 to ~5 mm when the applied voltage is changed from 0 to 28 Vrms. The response time of one cycle is ~2.5 s. Our liquid lens, with a low driving voltage for a large dynamic range, has potential applications in imaging, biometrics, optoelectronic, and lab-on-chip devices.

  12. Application of Foldable Intraocular Lens in Multiple Types of Cataract

    Institute of Scientific and Technical Information of China (English)

    Songtao Yuan; Qinghuai Liu; Qing Jiang; Nanrong Yuan

    2002-01-01

    Objective: To evaluate the clinical results of implantation of foldable intraocular lens inmultiple types of cataract.Methods: This retrospective study comprised 162 eyes of 148 patients undergoingphacoemulsification and implantation of foldable intraocular lens, some of whom under-went combined pars plana vitrectomy or trabeculectomy or silicone oil removal. Theperiod of follow-up was from 3 months to 17 months.Results: There is slight reaction postoperatively in all cases. The postoperative uncorrectedvisual acuites was from 0. 05 to 1.2, patient with 0.6 or above acuity were 70.98%. Aneodymium: YAG capsulotomy was required in 5 eyes. Posterior capsule ruptured in 1eyes, and a PMMA intraocular lens was implanted in ciliary sulcus. In one eye, a lenswas removed because of recurrence of retina detachment.Conclusions: The application of foldable intraocular lens in multiple types of cataract issafe, and there is a slight postoperative reaction. less complications , and fast visualacuity recovery.

  13. Observations of underdense plasma lens focusing of relativistic electron beams

    International Nuclear Information System (INIS)

    Focusing of a 15 MeV, 19 nC electron bunch by an underdense plasma lens operated just beyond the threshold of the underdense condition has been demonstrated in experiments at the Fermilab NICADD Photoinjector Laboratory (FNPL). The strong 1.9 cm focal-length plasma-lens focused both transverse directions simultaneously and reduced the minimum area of the beam spot by a factor of 23. Analysis of the beam-envelope evolution observed near the beam waist shows that the spherical aberrations of this underdense lens are lower than those of an overdense plasma lens, as predicted by theory. Correlations between the beam charge and the properties of the beam focus corroborate this conclusion

  14. Intraocular electro-optic lens with ciliary muscle controlled accommodation.

    Science.gov (United States)

    Doornaert, Dries; Glorieux, Christ; De Gersem, Herbert; Puers, Robert; Spileers, Werner; Blanckaert, Johan

    2013-01-01

    In this paper a concept is proposed of an intraocular lens implant with electro-optic accommodation of a variable-focus hybrid liquid-crystal-based lens. The dioptric strength of the lens is electronically controlled by a signal that is derived from the change of inductance of a sensing coil due to a marker implanted in the nearby contracting or decontracting ciliary muscle. Analytical, numerical and experimental results are reported on the dependency of the frequency of a Colpitts oscillator circuit on the location of a nearby conductive marker. A concept is also reported on the use as an electro-optic lens of a device based on a liquid crystal in planar alignment, which is held between a flat and a curved window coated with optically transparent and electrically conductive layers. PMID:24110406

  15. Perforation forces of the intact porcine anterior lens capsule.

    Science.gov (United States)

    Ullrich, Franziska; Lussi, Jonas; Felekis, Dimitrios; Michels, Stephan; Petruska, Andrew J; Nelson, Bradley J

    2016-09-01

    During the first step of cataract surgery, the lens capsule is perforated and a circular hole is created with a sharp instrument, a procedure called capsulorhexis. To develop automated systems that can assist ophthalmologists during capsulorhexis, the forces required must be quantified. This study investigates perforation forces of the central anterior lens capsule in porcine eyes, which are used as a conservative model for the human eye. A micro-mechanical characterisation method is presented that measures capsular bag perforation forces with a high precision positioning and high-resolution force sensing system. The force during perforation of the anterior lens capsule was measured with various sized needles and indentation speeds and is found to be 15-35mN. A bio-mechanical model is identified that describes an exponential correlation between indentation force and depth, indicating strain hardening behaviour of the porcine anterior lens capsule. PMID:27254279

  16. Applications of thermal lens spectrometry in food industry and agriculture.

    NARCIS (Netherlands)

    Franko, M.; Bicanic, D.; Gibkes, J.; Bremer, M.; Akkermans, E.

    1996-01-01

    Applications of CO laser dual beam thermal lens spectrometry (TLS) for detection and characterization of fatty acids, aldehydes, pesticides, and herbicides in liquid samples are described. Also reported is the first TLS measurement of thermal conductivity for oleic acid.

  17. Plasma lens experiments at the Final Focus Test Beam

    Energy Technology Data Exchange (ETDEWEB)

    Barletta, B. [California Univ., Los Angeles, CA (United States)]|[Lawrence Berkeley Lab., CA (United States); Chattopadhyay, S. [Lawrence Berkeley Lab., CA (United States); Chen, P. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)] [and others

    1993-04-01

    We intend to carry out a series of plasma lens experiments at the Final Focus Test Beam facility at SLAC. These experiments will be the first to study the focusing of particle beams by plasma focusing devices in the parameter regime of interest for high energy colliders, and is expected to lead to plasma lens designs capable of unprecedented spot sizes. Plasma focusing of positron beams will be attempted for the first time. We will study the effects of lens aberrations due to various lens imperfections. Several approaches will be applied to create the plasma required including laser ionization and beam ionization of a working gas. At an increased bunch population of 2.5 {times} 10{sup 10}, tunneling ionization of a gas target by an electron beam -- an effect which has never been observed before -- should be significant. The compactness of our device should prove to be of interest for applications at the SLC and the next generation linear colliders.

  18. An Atomic Lens Using a Focusing Hollow Beam

    Institute of Scientific and Technical Information of China (English)

    夏勇; 印建平; 王育竹

    2003-01-01

    We propose a new method to generate a focused hollow laser beam by using an azimuthally distributed 2π-phase plate and a convergent thin lens, and calculate the intensity distribution of the focused hollow beam in free propagation space. The relationship between the waist w0 of the incident collimated Gaussian beam and the dark spot size of the focused hollow beam at the focal point, and the relationship between the focal length f of the thin lens and the dark spot size are studied respectively. The optical potential of the blue-detuned focused hollow beam for 85Rb atoms is calculated. Our study shows that when the larger waist w of the incident Gaussian beam and the shorter focal length f of the lens are chosen, we can obtain an extremely small dark spot size of the focused hollow beam, which can be used to form an atomic lens with a resolution of several angstroms.

  19. Experimental Contact Lens to Prevent Glaucoma-Induced Blindness

    Science.gov (United States)

    ... An Experimental Contact Lens to Prevent Glaucoma-Induced Blindness By Sharon Reynolds Posted January 23, 2014 An ... group of conditions that can result in irreversible blindness. This vision loss can be reduced if glaucoma ...

  20. Constraints on cosmological models from lens redshift data

    CERN Document Server

    Cao, Shuo

    2011-01-01

    Strong lensing has developed into an important astrophysical tool for probing both cosmology and galaxies (their structures, formations, and evolutions). Now several hundreds of strong lens systems produced by massive galaxies have been discovered, which may form well-defined samples useful for statistical analyses. To collect a relatively complete lens redshift data from various large systematic surveys of gravitationally lensed quasars and check the possibility to use it as a future complementarity to other cosmological probes. We use the distribution of gravitationally-lensed image separations observed in the Cosmic Lens All-Sky Survey (CLASS), the PMN-NVSS Extragalactic Lens Survey (PANELS), the Sloan Digital Sky Survey (SDSS) and other surveys, considering a singular isothermal ellipsoid (SIE) model for galactic potentials as well as improved new measurements of the velocity dispersion function of galaxies based on the SDSS DR5 data and recent semi-analytical modeling of galaxy formation, to constrain tw...

  1. 30-Lens interferometer for high-energy X-rays.

    Science.gov (United States)

    Lyubomirskiy, Mikhail; Snigireva, Irina; Kohn, Victor; Kuznetsov, Sergey; Yunkin, Vyacheslav; Vaughan, Gavin; Snigirev, Anatoly

    2016-09-01

    A novel high-energy multi-lens interferometer consisting of 30 arrays of planar compound refractive lenses is reported. Under coherent illumination each lens array creates a diffraction-limited secondary source. Overlapping such coherent beams produces an interference pattern demonstrating strong longitudinal functional dependence. The proposed multi-lens interferometer was tested experimentally at the 100 m-long ID11 ESRF beamline in the X-ray energy range from 30 to 65 keV. The interference pattern generated by the interferometer was recorded at fundamental and fractional Talbot distances. An effective source size (FWHM) of the order of 15 µm was determined from the first Talbot image, proving the concept that the multi-lens interferometer can be used as a high-resolution tool for beam diagnostics. PMID:27577763

  2. Low-Cost Homemade Liquid-Lens Refractometer.

    Science.gov (United States)

    Narayanan, V. Anantha; Narayanan, Radha

    1996-01-01

    Describes the experimental and theoretical details for constructing and calibrating an inexpensive, homemade liquid-lens refractometer. Measures refractive indices that are within the experimental errors discussed and close to the literature values. (JRH)

  3. A 3D printed helical antenna with integrated lens

    KAUST Repository

    Farooqui, Muhammad Fahad

    2015-10-26

    A novel antenna configuration comprising a helical antenna with an integrated lens is demonstrated in this work. The antenna is manufactured by a unique combination of 3D printing of plastic material (ABS) and inkjet printing of silver nano-particle based metallic ink. The integration of lens enhances the gain by around 7 dB giving a peak gain of about 16.4 dBi at 9.4 GHz. The helical antenna operates in the end-fire mode and radiates a left-hand circularly polarized (LHCP) pattern. The 3-dB axial ratio (AR) bandwidth of the antenna with lens is 3.2 %. Due to integration of lens and fully printed processing, this antenna configuration offers high gain performance and requires low cost for manufacturing.

  4. Perforation forces of the intact porcine anterior lens capsule.

    Science.gov (United States)

    Ullrich, Franziska; Lussi, Jonas; Felekis, Dimitrios; Michels, Stephan; Petruska, Andrew J; Nelson, Bradley J

    2016-09-01

    During the first step of cataract surgery, the lens capsule is perforated and a circular hole is created with a sharp instrument, a procedure called capsulorhexis. To develop automated systems that can assist ophthalmologists during capsulorhexis, the forces required must be quantified. This study investigates perforation forces of the central anterior lens capsule in porcine eyes, which are used as a conservative model for the human eye. A micro-mechanical characterisation method is presented that measures capsular bag perforation forces with a high precision positioning and high-resolution force sensing system. The force during perforation of the anterior lens capsule was measured with various sized needles and indentation speeds and is found to be 15-35mN. A bio-mechanical model is identified that describes an exponential correlation between indentation force and depth, indicating strain hardening behaviour of the porcine anterior lens capsule.

  5. Eye lens irradiation by CT perfusion: dosimetry and optimization

    International Nuclear Information System (INIS)

    The lens of the eye is a radiosensitive organ. In April 2011, the International Commission on Radiological Protection (ICRP) set the new threshold dose of occurrence of deterministic lens effects to 500 mGy. Patients with a ruptured intracranial aneurysm are imaged by CT scans of the brain (CT), for diagnosis and post-treatment follow-up; embolization is the standard treatment. These iterative examinations expose the lens to X-rays. This paper evaluates the lens X-ray exposure of 18 patients who underwent encephalic CT scans after a ruptured intracranial aneurysm in 2011, and proposes a method to reduce this exposure. In our study, 44% of patients received eye doses greater than 500 mGy, generated by CT examinations, especially cerebral CT perfusion, necessary to assess the risk of delayed vasospasm/ischemia. By positioning the patient in neck hyper-flexion for cerebral CT perfusion, the dose could be reduced by around 50%. (authors)

  6. On the operational quantity Hp(3) for eye lens dosimetry

    International Nuclear Information System (INIS)

    In the past the operational quantity Hp(3) has been defined for calibration purposes in a slab phantom. Recently, an additional phantom in the form of a cylinder was suggested for eye lens dosimetry as a cylinder much better approximates the shape of a head than a slab. Therefore, this work investigates whether the quantity Hp(3), when defined in the respective calibration phantom, adequately estimates the eye lens dose (or is at least conservative) depending on the phantom: it turns out that in most cases both calibration phantoms are similarly well suited. Finally, the definition of the eye lens dose is discussed together with possible consequences on the definition of Hp(3): the consideration of only the radiation sensitive volume of the lens causes Hp(3) not to be conservative in beta radiation fields. (paper)

  7. Aldose reductase inhibitory activity and antioxidant capacity of pomegranate extracts

    OpenAIRE

    Karasu, Çimen; CUMAOĞLU, Ahmet; Gürpinar, Ali Rifat; Kartal, Murat; Kovacikova, Lucia; Milackova, Ivana; Stefek, Milan

    2012-01-01

    The pomegranate, Punica granatum L., has been the subject of current interest as a medicinal agent with wide-ranging therapeutic indications. In the present study, pomegranate ethanolic seed and hull extracts were tested, in comparison with a commercial sample, for the inhibition of aldose reductase, an enzyme involved in the etiology of diabetic complications. In vitro inhibition of rat lens aldose reductase was determined by a conventional method. Pomegranate ethanolic hull extract and comm...

  8. Fabrication of Micro Lens Array by UV-LED Lithography

    Science.gov (United States)

    Iguchi, Yusuke; Matsumoto, Yoshinori

    High curvature micro lens array of 240-570 μm diameters and 110-270 μm heights has been fabricated by using UV-LED lithography and imprinting technique. Curved SU-8 structures were fabricated by backside exposure through thin glass substrate because UV-LED array light source has wide directivity characteristics of UV dose. The structure was transferred to Polydimethylsiloxsane (PDMS) mold. Micro lens array of photosensitive acrylic resin was fabricated by using the mold.

  9. Management of endophthalmitis while preserving the uninvolved crystalline lens

    Directory of Open Access Journals (Sweden)

    Townsend J

    2012-03-01

    Full Text Available Justin Townsend, Avinash Pathengay, Harry W Flynn Jr, Darlene MillerDepartment of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, FL, USABackground: The purpose of this work is to report on the management of endophthalmitis in phakic eyes in which the crystalline lens was preserved.Methods: The current study is a noncomparative consecutive case series of patients who developed culture-proven endophthalmitis and were treated between January 1995 and June 2009. The study included only phakic patients whose infection was managed without removal of the crystalline lens. Using a computerized search of Microbiology Department records, patients were identified with phakic lens status and clinically diagnosed endophthalmitis.Results: A total of 12 phakic eyes from 11 patients met the study criteria. The etiology of infection was endogenous (n = 6, postoperative (n = 5, and post-traumatic (n = 1. Pars plana vitrectomy and injection of intravitreal antimicrobials was performed in seven eyes (58%, and vitreous tap and injection of antimicrobials was performed in five eyes (42%. All eyes showed progression of lens opacification after treatment. Overall, nine (75% achieved visual acuity outcomes ≥20/80, including five of seven (71% eyes treated with vitrectomy and four of five eyes (80% treated with injection of antibiotics alone. One of seven eyes (14% treated with vitrectomy had a poor visual outcome (defined as <20/400 compared with one of five (20% eyes treated with intravitreal antimicrobials alone. During follow-up, all 12 eyes had progression of lens opacification and five of 12 (42% eyes underwent cataract surgery with posterior chamber intraocular lens placement.Conclusion: In phakic patients, successful treatment of endophthalmitis can be achieved while preserving the uninvolved crystalline lens. Future cataract surgery with posterior chamber intraocular lens placement can be accomplished in many

  10. Signal-enhancement reflective pulse oximeter with Fresnel lens

    Science.gov (United States)

    Chung, Shuang-Chao; Sun, Ching-Cherng

    2016-09-01

    In this paper, a new reflective pulse oximeter is proposed and demonstrated with implanting a Fresnel lens, which enhances the reflected signal. An optical simulation model incorporated with human skin characteristics is presented to evaluate the capability of the Fresnel lens. In addition, the distance between the light emitting diode and the photodiode is optimized. Compared with the other reflective oximeters, the reflected signal light detected by the photodiode is enhanced to more than 140%.

  11. Softec HD hydrophilic acrylic intraocular lens: biocompatibility and precision

    OpenAIRE

    Ladan Espandar; Shameema Sikder; Majid Moshirfar

    2011-01-01

    Ladan Espandar1, Shameema Sikder2, Majid Moshirfar31Department of Ophthalmology, Tulane University, New Orleans, LA, USA; 2Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD, USA; 3John A Moran Eye Center, University of Utah, Salt Lake City, UT, USAAbstract: Intraocular lens development is driven by higher patient expectations for ideal visual outcomes. The recently US Food and Drug Administration-approved Softec HD™ lens is an aspheric, hydrophilic acrylic intraocular le...

  12. Patient acceptability of the Tecnis® multifocal intraocular lens

    OpenAIRE

    Woodward, Maria; Sood,Priyanka

    2011-01-01

    Priyanka Sood1, Maria A Woodward21Emory Eye Center, Atlanta, GA, USA; 2Kellogg Eye Center, Ann Arbor, MI, USAAbstract: Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL) designs. The Tecnis® Multifocal Intraocular Lens incorporates an aspheric, modified anter...

  13. OPTICAL REALIZATION OF WAVELET TRANSFORM WITH A SINGLE LENS

    Institute of Scientific and Technical Information of China (English)

    王取泉; 熊贵光; 李承芳; 张苏淮; 王琳

    2001-01-01

    Two optical set-ups to implement wavelet transform with a single lens have been proposed, in which the wavelet filter was placed in front of the imaging lens or on the frequency plane. The general formula of the complex field distribution of the output plane has been deduced. The analysing wavelet functions of the band-pass wavelet filters with double and circular slits have been discussed.

  14. Supersymmetric black holes with lens-space topology.

    Science.gov (United States)

    Kunduri, Hari K; Lucietti, James

    2014-11-21

    We present a new supersymmetric, asymptotically flat, black hole solution to five-dimensional supergravity. It is regular on and outside an event horizon of lens-space topology L(2,1). It is the first example of an asymptotically flat black hole with lens-space topology. The solution is characterized by a charge, two angular momenta, and a magnetic flux through a noncontractible disk region ending on the horizon, with one constraint relating these.

  15. Ball Lens Fiber Optic Sensor based Smart Handheld Microsurgical Instrument

    OpenAIRE

    Song, Cheol; Gehlbach, Peter L.; Kang, Jin U.

    2013-01-01

    During freehand performance of vitreoretinal microsurgery the surgeon must perform precise and stable maneuvers that achieve surgical objectives and avoid surgical risk. Here, we present an improved smart handheld microsurgical tool which is based on a ball lens fiber optic sensor that utilizes common path swept source optical coherence tomography. Improvements include incorporation of a ball lens single mode fiber optic probe that increases the working angle of the tool to greater than 45 de...

  16. AO-OCT for in vivo mouse retinal imaging: Application of adaptive lens in wavefornt sensorless aberration correction

    Science.gov (United States)

    Bonora, Stefano; Jian, Yifan; Pugh, Edward N.; Sarunic, Marinko V.; Zawadzki, Robert J.

    2014-03-01

    We demonstrate Adaptive optics - Optical Coherence Tomography (OCT) with modal sensorless Adaptive Optics correction with the use of novel Adaptive Lens (AL) applied for in-vivo imaging of mouse retinas. The AL can generate low order aberrations: defocus, astigmatism, coma and spherical aberration that were used in an adaptive search algorithm. Accelerated processing of the OCT data with a Graphic Processing Unit (GPU) permitted real time extraction of image projection total intensity for arbitrarily selected retinal depth plane to be optimized. Wavefront sensorless control is a viable option for imaging biological structures for which AOOCT cannot establish a reliable wavefront that could be corrected by wavefront corrector. Image quality improvements offered by adaptive lens with sensorless AO-OCT was evaluated on in vitro samples followed by mouse retina data acquired in vivo.

  17. The Clearing : Heidegger’s Lichtung and the big scrub

    Directory of Open Access Journals (Sweden)

    Garbutt, Rob

    2010-01-01

    Full Text Available Clearings make settlement possible. Whether on a small scale using an axe and other hand implements to make way for a dwelling and a garden, or on a large scale with a chain strung between two D9 bulldozers in preparation for a major agribusiness development, the process of clearing creates spaces for installing something new. This paper uses the idea of (the clearing, as practice, process, outcome and metaphor, to examine the installation of the locals in a settler society. Using Lismore on the far-north coast of New South Wales, Australia, as a case example, the particular work of clearing that is discussed here is a practice that enables a form of colonisation and settlement that distances itself from its history of migration. This is a history of settler locals who were 'always here', and a colonial form of clearing clears the land and the mind of troubling pasts and of troubling presences. For the locals within a place, then, clearing manages and simplifies a complex set of social and material relations, histories and identities.Using Anthony Appiah's concept the 'space clearing gesture', the paper concludes with a reflection on the space in which the idea of "the clearing" and this paper appears. Do places, in this instance rural places, provide a type of clearing in which certain ideas might appear that may not appear elsewhere? If situatedness matters then the diversity of places where thinking is done is important for our ecology of thought, and in connection with this, perhaps what 'rural cultural studies' does is clear a particular type of space for thinking.

  18. The Clearing: Heidegger’s Lichtung and The Big Scrub

    Directory of Open Access Journals (Sweden)

    Rob Garbutt

    2010-02-01

    Full Text Available Clearings make settlement possible. Whether on a small scale using an axe and other hand implements to make way for a dwelling and a garden, or on a large scale with a chain strung between two D9 bulldozers in preparation for a major agribusiness development, the process of clearing creates spaces for installing something new. This paper uses the idea of (the clearing, as practice, process, outcome and metaphor, to examine the installation of the locals in a settler society. Using Lismore on the far-north coast of New South Wales, Australia, as a case example, the particular work of clearing that is discussed here is a practice that enables a form of colonisation and settlement that distances itself from its history of migration. This is a history of settler locals who were 'always here', and a colonial form of clearing clears the land and the mind of troubling pasts and of troubling presences. For the locals within a place, then, clearing manages and simplifies a complex set of social and material relations, histories and identities. Using Anthony Appiah's concept the 'space clearing gesture', the paper concludes with a reflection on the space in which the idea of "the clearing" and this paper appears. Do places, in this instance rural places, provide a type of clearing in which certain ideas might appear that may not appear elsewhere? If situatedness matters then the diversity of places where thinking is done is important for our ecology of thought, and in connection with this, perhaps what 'rural cultural studies' does is clear a particular type of space for thinking.

  19. Task-based evaluation of practical lens designs for lens-coupled digital mammography systems

    Science.gov (United States)

    Chen, Liying; Foo, Leslie D.; Cortesi, Rebecca L.; Thompson, Kevin P.; Barrett, Harrison H.

    2007-03-01

    Recent developments in low-noise, large-area CCD detectors have renewed interest in radiographic systems that use a lens to couple light from a scintillation screen to a detector. The lenses for this application must have very large numerical apertures and high spatial resolution over a FOV. This paper expands on our earlier work by applying the principles of task-based assessment of image quality to development of meaningful figures of merit for the lenses. The task considered in this study is detection of a lesion in a mammogram, and the figure of merit used is the lesion detectability, expressed as a task-based signal-to-noise ratio (SNR), for a channelized Hotelling observer (CHO). As in the previous work, the statistical model accounts for the random structure in the breast, the statistical properties of the scintillation screen, the random coupling of light to the CCD, the detailed structure of the shift-variant lens point spread function (PSF), and Poisson noise of the X-ray flux. The lenses considered range from F/0.9 to F/1.2. All yield nominally the same spot size at a given field. Among the F/0.9 lenses, some of them were designed by conventional means for high resolution and some for high contrast, and the shapes of the PSF differ considerably. The results show that excessively large lens numerical apertures do not improve the task-based SNR but dramatically increase the optics fabrication cost. Contrary to common wisdom, high-contrast designs have higher task-based SNRs than high-resolution designs when the signal is small. Additionally, we constructed a merit function to successfully tune the lenses to perform equally well anywhere in the FOV.

  20. The Embedded Transparent Lens and Fermat's Least-Time Principle

    CERN Document Server

    Kantowski, Ronald; Dai, Xinyu

    2013-01-01

    We present a much simplified version of the embedded point mass lens theory and then make the obvious extension of this theory to any embedded transparent lens. Embedding a lens effectively reduces the gravitational potential's range, i.e., partially shields the lensing potential because the lens mass is made a contributor to the mean mass density of the universe and not simply superimposed upon it. This presentation results from simplifying previous formulations of the embedded point mass theory and is quite similar to the standard theory. We are then able to re-derive the simplified point mass theory by applying Fermat's least-time principle to the time-delay function. Even though rigorous derivations are only made for the point mass, the lens equation to the lowest order for any distributed lens, is obvious. We find from this simplified theory that embedding can introduce corrections at the few percent level in weak lensing shears caused by large clusters but only at large impacts. The potential part of th...

  1. Self retaining contact lens system for vitreous surgery

    Directory of Open Access Journals (Sweden)

    Chalam Kakarla

    2004-01-01

    Full Text Available We describe the principle and design of a new self-retaining contact lens system for vitreous surgery. The system has three lenses: the plano-concave, prism and magnifying lens. This system is based on the principle of a direct imaging contact lens, designed for a 150-200mm focal length operating microscope. The contact lenses are designed to have an inferior concave surface [radius of curvature (ROC 7.7mm], modified by the addition of four footplates to provide stability and centration during vitreous surgery. The lenses are used with a drop of viscoelastic material placed between the concave surface of the contact lens and cornea. This induces negative suction and helps retain the lens in position during surgery. These specially designed lenses provide a stable, well-centered, high-resolution, magnified view of the fundus. This system eliminates the need for a skilled assistant or for suturing the lens to the sclera during vitreous surgery.

  2. Flat Lens Focusing Demonstrated With Left-Handed Metamaterial

    Science.gov (United States)

    Wilson, Jeffrey D.; Schwartz, Zachary D.; Chevalier, Christine T.; Downey, Alan N.; Vaden, Karl R.

    2004-01-01

    Left-handed metamaterials (LHM's) are a new media engineered to possess an effective negative index of refraction over a selected frequency range. This characteristic enables LHM's to exhibit physical properties never before observed. In particular, a negative index of refraction should cause electromagnetic radiation to refract or bend at a negative angle when entering an LHM, as shown in the figure above on the left. The figure on the right shows that this property could be used to bring radiation to a focus with a flat LHM lens. The advantage of a flat lens in comparison to a conventional curved lens is that the focal length could be varied simply by adjusting the distance between the lens and the electromagnetic wave source. In this in-house work, researchers at the NASA Glenn Research Center developed a computational model for LHM's with the three-dimensional electromagnetic commercial code Microwave Studio, constructed an LHM flat lens, and used it to experimentally demonstrate the reversed refraction and flat lens focusing of microwave radiation.

  3. The PCA Lens-Finder: application to CFHTLS

    CERN Document Server

    Paraficz, D; Tramacere, A; Joseph, R; Metcalf, R B; Kneib, J -P; Dubath, P; Droz, D; Filleul, F; Ringeisen, D; Schäfer, C

    2016-01-01

    We present the results of a new search for galaxy-scale strong lensing systems in CFHTLS Wide. Our lens-finding technique involves a preselection of potential lens galaxies, applying simple cuts in size and magnitude. We then perform a Principal Component Analysis of the galaxy images, ensuring a clean removal of the light profile. Lensed features are searched for in the residual images using the clustering topometric algorithm DBSCAN. We find 1098 lens candidates that we inspect visually, leading to a cleaned sample of 109 new lens candidates. Using realistic image simulations we estimate the completeness of our sample and show that it is independent of source surface brightness, Einstein ring size (image separation) or lens redshift. We compare the properties of our sample to previous lens searches in CFHTLS. Including the present search, the total number of lenses found in CFHTLS amounts to 678, which corresponds to ~4 lenses per square degree down to i=24.8. This is equivalent to ~ 60.000 lenses in total ...

  4. The correction of electron lens aberrations

    Energy Technology Data Exchange (ETDEWEB)

    Hawkes, P.W., E-mail: peter.hawkes@cemes.fr

    2015-09-15

    The progress of electron lens aberration correction from about 1990 onwards is chronicled. Reasonably complete lists of publications on this and related topics are appended. A present for Max Haider and Ondrej Krivanek in the year of their 65th birthdays. By a happy coincidence, this review was completed in the year that both Max Haider and Ondrej Krivanek reached the age of 65. It is a pleasure to dedicate it to the two leading actors in the saga of aberration corrector design and construction. They would both wish to associate their colleagues with such a tribute but it is the names of Haider and Krivanek (not forgetting Joachim Zach) that will remain in the annals of electron optics, next to that of Harald Rose. I am proud to know that both regard me as a friend as well as a colleague. - Highlights: • Geometrical aberration correction. • Chromatic aberration correction. • 50 pm resolution. • High-resolution electron energy-loss spectroscopy. • Extensive bibliographies.

  5. Reminiscence through the Lens of Social Media.

    Science.gov (United States)

    Thomas, Lisa; Briggs, Pam

    2016-01-01

    Reminiscence is used to support and create new social bonds and give meaning to life. Originally perceived as a preoccupation of the aged, we now recognize that reminiscence has value throughout the lifespan. Increasingly, social media can be used to both support and prompt reminiscence, with Facebook's Lookback or Year in Review as recent examples. This work takes prompted reminiscence further, asking what forms and functions of reminiscence are supported by social media. Utilizing the online service MySocialBook, we invited participants to curate content from their personal Facebook account to then be transformed into a printed book. We used that book as a prompt for discussion of the reminiscence function of the curated material, using Westerhof and Bohlmeijer's (2014) reminiscence framework as a starting point. We conclude that this framework is valuable in understanding the role of social media in reminiscence, but note that earlier models, such as Webster's Reminiscence Functions Scale, are also relevant. We contribute to the reminiscence debate by adding a technological lens to the process of life review, whilst concurring with other researchers in this field that a robust conceptual framework is lacking, particularly when considering the forms of reminiscence that are most salient for younger people. PMID:27378971

  6. Ubercalibration of the Deep Lens Survey

    CERN Document Server

    Wittman, D; Thorman, P

    2011-01-01

    We describe the internal photometric calibration of the Deep Lens Survey, which consists of five widely separated fields observed by two different observatories. Adopting the global linear least-squares ("ubercal") approach developed for the Sloan Digital Sky Survey (SDSS), we derive flatfield corrections for all observing runs, which indicate that the original sky flats were nonuniform by up to 0.13 mag peak to valley in $\\z$ band, and by up to half that amount in {\\it BVR}. We show that application of these corrections reduces spatial nonuniformities in corrected exposures to the 0.01-0.02 mag level. We conclude with some lessons learned in applying ubercal to a survey structured very differently from SDSS, with isolated fields, multiple observatories, and shift-and-stare rather than drift-scan imaging. Although the size of the error caused by using sky or dome flats is instrument- and wavelength-dependent, users of wide-field cameras should not assume that it is small. Pipeline developers should facilitate...

  7. Reminiscence through the Lens of Social Media

    Science.gov (United States)

    Thomas, Lisa; Briggs, Pam

    2016-01-01

    Reminiscence is used to support and create new social bonds and give meaning to life. Originally perceived as a preoccupation of the aged, we now recognize that reminiscence has value throughout the lifespan. Increasingly, social media can be used to both support and prompt reminiscence, with Facebook’s Lookback or Year in Review as recent examples. This work takes prompted reminiscence further, asking what forms and functions of reminiscence are supported by social media. Utilizing the online service MySocialBook, we invited participants to curate content from their personal Facebook account to then be transformed into a printed book. We used that book as a prompt for discussion of the reminiscence function of the curated material, using Westerhof and Bohlmeijer’s (2014) reminiscence framework as a starting point. We conclude that this framework is valuable in understanding the role of social media in reminiscence, but note that earlier models, such as Webster’s Reminiscence Functions Scale, are also relevant. We contribute to the reminiscence debate by adding a technological lens to the process of life review, whilst concurring with other researchers in this field that a robust conceptual framework is lacking, particularly when considering the forms of reminiscence that are most salient for younger people. PMID:27378971

  8. Dark energy with gravitational lens time delays

    CERN Document Server

    Treu, T; Cyr-Racine, F -Y; Fassnacht, C D; Keeton, C R; Linder, E V; Moustakas, L A; Bradac, M; Buckley-Geer, E; Collett, T; Courbin, F; Dobler, G; Finley, D A; Hjorth, J; Kochanek, C S; Komatsu, E; Koopmans, L V E; Meylan, G; Natarajan, P; Oguri, M; Suyu, S H; Tewes, M; Wong, K C; Zabludoff, A I; Zaritsky, D; Anguita, T; Brunner, R J; Cabanac, R; Falco, E E; Fritz, A; Seidel, G; Howell, D A; Giocoli, C; Jackson, N; Lopez, S; Metcalf, R B; Motta, V; Verdugo, T

    2013-01-01

    Strong lensing gravitational time delays are a powerful and cost effective probe of dark energy. Recent studies have shown that a single lens can provide a distance measurement with 6-7 % accuracy (including random and systematic uncertainties), provided sufficient data are available to determine the time delay and reconstruct the gravitational potential of the deflector. Gravitational-time delays are a low redshift (z~0-2) probe and thus allow one to break degeneracies in the interpretation of data from higher-redshift probes like the cosmic microwave background in terms of the dark energy equation of state. Current studies are limited by the size of the sample of known lensed quasars, but this situation is about to change. Even in this decade, wide field imaging surveys are likely to discover thousands of lensed quasars, enabling the targeted study of ~100 of these systems and resulting in substantial gains in the dark energy figure of merit. In the next decade, a further order of magnitude improvement will...

  9. Bloqueio extraconal para facectomia com implante de lente intra-ocular: influência da via de acesso (superior ou inferior na qualidade da anestesia Bloqueo extraconal para facectomia con implantación de lente intra-ocular: influencia de la vía de acceso (superior o inferior en la calidad de la anestesia Extraconal block for cataract extraction surgery with implantation of intraocular lens: influence of access way (upper or lower in anesthetic outcome

    Directory of Open Access Journals (Sweden)

    Daniel Espada Lahoz

    2003-08-01

    bloqueo locorregional para cirugía de facectomia con implantación de lente intra-ocular.BACKGROUND AND OBJECTIVES: There is no completely safe anesthetic technique for ophthalmic surgery. The introduction of extraconal anesthesia has increased the number of ophthalmic surgeries with blockade since the incidence of severe complications is lower, as reported by Hay in 1991. Extraconal blockades may be induced by several access ways, among them upper and lower ways. This study aimed at evaluating the influence access ways (upper or lower in anesthetic outcome. METHODS: Participated in this study 164 patients of both genders, aged 23 to 92 years, physical status ASA I to IV, 1 and 2 Goldman’s cardiac risk index, undergoing elective cataract extraction surgery with intraocular lens implantation. Patients were randomly distributed in two groups of 82 according to primary extraconal block access way: group UE (upper extraconal, group LE (lower extraconal. Blockade quality was evaluated by the following parameters: intraoperative pain, eyelid and/or eyeball movement, persistence of Bell´s reflex, number of blocks needed for eye akinesia, and surgeon’s evaluation. RESULTS: Upper extraconal approach was associated to more effective eyelid (upper access - 56.1%; lower access 36.6% and superior rectus muscle akinesia (upper access - 93.9%; lower access 65.9% and also a lower incidence of supplementary blocks (upper access - 29.3%; lower access 42.7%. The lower extraconal approach was associated to more effective inferior rectus muscle akinesia (upper access - 72%; lower access - 84.1%, however without statistical differences. CONCLUSIONS: In the conditions of this study the upper extraconal approach was better as compared to the lower approach as the primary access way for anesthetic block for cataract extraction with intraocular lens implantation.

  10. A New Type of distributed Enamel based Clearing Electrode

    CERN Document Server

    Kroyer, T; Caspers, Friedhelm; Hellmond, P; Métral, E; Wendel, J C; Zimmermann, F

    2007-01-01

    Clearing electrodes can be used for electron cloud (EC) suppression in high intensity particle accelerators. In this paper the use of low and highly resistive layers on a dielectric substrate are examined. The beam coupling impedance of such a structure is evaluated. Furthermore the clearing efficiency as well as technological issues are discussed.

  11. 78 FR 72475 - Derivatives Clearing Organizations and International Standards

    Science.gov (United States)

    2013-12-02

    ... organizations) H. Regulation 39.36 (Risk management for systemically important derivatives clearing... of material risk-related rule changes by systemically important derivatives clearing organizations) O... Market Utilities as Systemically Important, 76 FR 44763, 44774 (July 27, 2011) (final rule)....

  12. 78 FR 50259 - Derivatives Clearing Organizations and International Standards

    Science.gov (United States)

    2013-08-16

    ... Clearing Organizations) H. Regulation 39.36 (Risk Management for Systemically Important Derivatives... market participants, strengthen the risk management practices of DCOs, and increase overall confidence in...-554, 114 Stat. 2763 (2000). \\5\\ See A New Regulatory Framework for Clearing Organizations, 66 FR...

  13. ClearPEM: prototype PET device dedicated to breast imaging

    CERN Multimedia

    Joao Varela

    2009-01-01

    Clinical trials have begun in Portugal on a new breast imaging system (ClearPEM) using positron emission tomography (PET). The system, developed by a Portuguese consortium in collaboration with CERN and laboratories participating in the Crystal Clear collaboration, will detect even the smallest tumours and thus help avoid unnecessary biopsies.

  14. 75 FR 77576 - General Regulations and Derivatives Clearing Organizations

    Science.gov (United States)

    2010-12-13

    ... company or organization, or equivalent governing body.'' See 75 FR at 63747. Proposed Sec. 39.10(c)(1)(iii... COMMISSION 17 CFR Parts 1 and 39 RIN 3038-AC98 General Regulations and Derivatives Clearing Organizations... amendments would establish the regulatory standards for compliance with derivatives clearing...

  15. HIGH-CURRENT COLD CATHODE FIELD EMISSION ARRAY FOR ELECTRON LENS APPLICATION

    Energy Technology Data Exchange (ETDEWEB)

    Hirshfield, Jay L

    2012-12-28

    During Phase I, the following goals were achieved: (1) design and fabrication of a novel, nano-dimensional CNT field emitter assembly for high current density application, with high durability; (2) fabrication of a ceramic based micro channel plate (MCP) and characterization of its secondary electron emission; and (3) characterizing the CNT/MCP cathode for high field emission and durability. As a result of these achievements, a relatively high current density of ~ 1.2 A/cm2 from a CNT cathode and single channel MCP were measured. The emission current was also extremely stable with a peak-to-peak variation of only 1.8%. The emission current could be further enhanced to meet requirements for electron lens applications by increasing the number of MCP channels. A calculation for maximum possible current density with a 1200 channel/cm2 MCP, placed over a cathode with 1200 uniformly functioning CNTs, would be ~1.46 kA/cm2, neglecting space charge limitations. Clearly this level of emission is far greater than what is needed for the electron lens application, but it does offer a highly comforting margin to account for sub-standard emitters and/or to allow the lesser challenge of building a cathode with fewer channels/cm2. A satisfactory goal for the electron lens application would be a controllable emission of 2-4 mA per channel in an ensemble of 800-1200 uniformly-functioning channels/cm2, and a cathode with overall area of about 1 cm2.

  16. Comparison of skin optical clearing by different drug delivery method

    International Nuclear Information System (INIS)

    Previous studies have shown that optical clearing techniques have great potential for optical diagnosis and therapy. In order to further discuss the effect by different drug delivery method, diffusion chambers were used to simulate in vivo physiological environment; and the optical clearing agents were acted on the surface of porcine skin, the saline was contacted with the dermal side (epidermal application). Then they were compared with the traditional method-samples immersed in the optical clearing agents (mainly dermal immersion). The transmission intensity of skin was monitored by an integrating sphere system. The changes in thickness were measured before and after experiments. The results showed that the optical clearing effect and the changes in thickness are not coincident under the two different methods. It indicates that the optical clearing effect and mechanism may relate to the drug delivery method.

  17. Comparison of skin optical clearing by different drug delivery method

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Z; Ge, X [Department of Fundamental Theories, Shandong Sports University, Jinan, 250102 (China); Li, E, E-mail: mm73@163.com [Institute of Physical Education, Huazhong Normal University, Wuhan, 430079 (China)

    2011-01-01

    Previous studies have shown that optical clearing techniques have great potential for optical diagnosis and therapy. In order to further discuss the effect by different drug delivery method, diffusion chambers were used to simulate in vivo physiological environment; and the optical clearing agents were acted on the surface of porcine skin, the saline was contacted with the dermal side (epidermal application). Then they were compared with the traditional method-samples immersed in the optical clearing agents (mainly dermal immersion). The transmission intensity of skin was monitored by an integrating sphere system. The changes in thickness were measured before and after experiments. The results showed that the optical clearing effect and the changes in thickness are not coincident under the two different methods. It indicates that the optical clearing effect and mechanism may relate to the drug delivery method.

  18. A simple formula for determining globally clear skies

    Energy Technology Data Exchange (ETDEWEB)

    Long, C.N.; George, A.T.; Mace, G.G. [Penn State Univ., University Park, PA (United States)] [and others

    1996-04-01

    Surface measurements to serve as {open_quotes}ground truth{close_quotes} are of primary importance in the development of retrieval algorithms using satellite measurements to predict surface irradiance. The most basic algorithms of this type deal with clear sky (i.e., cloudless) top-to-surface shortwave (SW) transfer, serving as a necessary prerequisite towards treating both clear and cloudy conditions. Recently, atmosphere SW cloud forcing to infer the possibility of excess atmospheric absorption (compared with model results) in cloudy atmospheres. The surface component of this ratio relies on inferring the expected clear sky SW irradiance to determine the effects of clouds on the SW energy budget. Solar renewable energy applications make use of clear and cloud fraction climatologies to assess solar radiation resources. All of the above depend to some extent on the identification of globally clear sky conditions and the attendant measurements of downwelling SW irradiance.

  19. Lens positioner with five degrees of freedom

    International Nuclear Information System (INIS)

    A device for positioning lenses precisely with five degrees of freedom (three translations and two angular rotations). The unique features of the device are its compact design, large clear aperture, and high degree of positioning accuracy combined with five degrees of freedom in axis motion. Thus, the device provides precision and flexibility in positioning of optical components

  20. The Sloan-Lens ACS Survey II: stellar populations and internal structure of early-type lens galaxies

    CERN Document Server

    Treu, T; Burles, S; Koopmans, L; Moustakas, L; Bolton, Adam; Burles, Scott; Koopmans, Leon; Moustakas, Leonidas; Treu, Tommaso

    2006-01-01

    We derive Fundamental Plane parameters of 15 early-type lens galaxies identified by the Sloan Lens ACS (SLACS) Survey. The size of the sample allows us to investigate for the first time the distribution of lens galaxies in the FP space. After correcting for evolution, we find that lens galaxies occupy a subset of the local FP. The edge-on projection (approximately M vs M/L) is indistinguishable from that of normal early-type galaxies. However -- within the fundamental plane -- the lens galaxies appear to concentrate at the edge of the region populated by normal early-type galaxies. We show that this is a result of our selection procedure (approximately velocity dispersion sigma>240km/s). We conclude that SLACS lenses are a fair sample of high velocity dispersion early-type galaxies. By comparing the central stellar velocity dispersion that of the best fit lens model, we find == =1.01+-0.02 with 0.065 rms scatter. We conclude that within the Einstein radii the SLACS lenses are very well approximated by isother...

  1. A role for smoothened during murine lens and cornea development.

    Directory of Open Access Journals (Sweden)

    Janet J Y Choi

    Full Text Available Various studies suggest that Hedgehog (Hh signalling plays roles in human and zebrafish ocular development. Recent studies (Kerr et al., Invest Ophthalmol Vis Sci. 2012; 53, 3316-30 showed that conditionally activating Hh signals promotes murine lens epithelial cell proliferation and disrupts fibre differentiation. In this study we examined the expression of the Hh pathway and the requirement for the Smoothened gene in murine lens development. Expression of Hh pathway components in developing lens was examined by RT-PCR, immunofluorescence and in situ hybridisation. The requirement of Smo in lens development was determined by conditional loss-of-function mutations, using LeCre and MLR10 Cre transgenic mice. The phenotype of mutant mice was examined by immunofluorescence for various markers of cell cycle, lens and cornea differentiation. Hh pathway components (Ptch1, Smo, Gli2, Gli3 were detected in lens epithelium from E12.5. Gli2 was particularly localised to mitotic nuclei and, at E13.5, Gli3 exhibited a shift from cytosol to nucleus, suggesting distinct roles for these transcription factors. Conditional deletion of Smo, from ∼E12.5 (MLR10 Cre did not affect ocular development, whereas deletion from ∼E9.5 (LeCre resulted in lens and corneal defects from E14.5. Mutant lenses were smaller and showed normal expression of p57Kip2, c-Maf, E-cadherin and Pax6, reduced expression of FoxE3 and Ptch1 and decreased nuclear Hes1. There was normal G1-S phase but decreased G2-M phase transition at E16.5 and epithelial cell death from E14.5-E16.5. Mutant corneas were thicker due to aberrant migration of Nrp2+ cells from the extraocular mesenchyme, resulting in delayed corneal endothelial but normal epithelial differentiation. These results indicate the Hh pathway is required during a discrete period (E9.5-E12.5 in lens development to regulate lens epithelial cell proliferation, survival and FoxE3 expression. Defective corneal development occurs

  2. Negative refractive perfect lens vs Spherical geodesic lens. Perfect Imaging comparative analysis

    CERN Document Server

    Gonzalez, Juan C; Minano, Juan C; Grabovickic, Dejan

    2012-01-01

    Negative Refractive Lens (NRL) has shown that an optical system can produce images with details below the classic Abbe diffraction limit. This optical system transmits the electric field, emitted by the object surface, towards the image surface producing the same field distribution in both surfaces. In particular, a Dirac delta electric field in the object surface is focused without diffraction limit to the Dirac delta electric field in the image surface. The Maxwell Fish Eye lens (MFE) and the Spherical Geodesic Waveguide (SGW) have been claimed to break the diffraction limit using positive refraction with a different meaning. In these cases, it has been considered the power transmission from a point source to a point receptor, which falls drastically when the receptor is displaced from the focus by a distance much smaller than the wavelength. Although these systems can detect displacements up to Wavelength/500, they cannot be compared to the NRL, since the concept of the object and image surface is not esta...

  3. Ascorbic acid glycation of lens proteins produces UVA sensitizers similar to those in human lens

    International Nuclear Information System (INIS)

    Soluble calf lens proteins were extensively glycated during a 4 week incubation with ascorbic acid in the presence of oxygen. Amino acids analysis of the dialyzed proteins removed at weekly intervals showed an increasing loss of lysine, arginine and histidine, consistent with the extensive protein cross-linking observed. Irradiation of the dialyzed samples with UVA light (1.0 kJ/cm2 total illumination through a 338 nm cutoff filter) caused an increasing loss of tryptophan, an additional loss of histidine and the production of micromolar concentrations of hydrogen peroxide. No alteration in amino acid content and no photolytic effects were seen in proteins incubated without ascorbic acid in proteins incubated with glucose for 4 weeks. The rate of hydrogen peroxide formation was linear with each glycated sample with a maximum production of 25 nmol/mg protein illuminated. The possibility that the sensitizer activity was due to an ascorbate-induced oxidation of tryptophan was eliminated by the presence of a heavy metal ion chelator during the incubation and by showing equivalent effects with ascorbate-incubated ribonuclease A, which is devoid of tryptophan. The ascorbate-incubated samples displayed increasing absorbance at wavelengths above 300 nm and increasing fluorescence (340/430) as glycation proceeded. The spectra of the 4 week glycated proteins were identical to those obtained with a solubilized water-insoluble fraction from human lens, which is known to have UVA sensitizer activity. (Author)

  4. Evaluation of resources for contact lens practice in private contact lens clinics of Muscat, Oman

    Directory of Open Access Journals (Sweden)

    Rajiv Khandekar

    2009-01-01

    Materials and Methods: This study was conducted between May and July 2006. A team of optometrists and health inspectors visited clinics and collected information about the infrastructure, available human resources, and materials used in the CL practice. We used a pre-tested close-ended questionnaire to collect responses of the practitioners and observations of the field staff. Statistical Method: Univariate parametric type of analysis. Results: The team visited 67 CL clinics and interviewed 75 CL practitioners. Proper hand washing facility was available at 61 clinics. Thirty-nine practitioners had> 10 years of experience in dispensing contact lenses. Only 13 clinics had a bio-microscope. None of the clinics had legal documents signed by both providers and end users of the contact lens. Conclusions: Contact lens has received less attention in areas outside the developed world. The CL practice in the private sectors of Oman needs to be strengthened. Minimum standards, standard operating procedures for CL practice, and its periodic supervision would be useful.

  5. Evaluating the cytotoxicity of contact lens multi-purpose solutions in an in vitro lens system

    Directory of Open Access Journals (Sweden)

    O. Matthew Oriowo

    2009-12-01

    Full Text Available Purpose: To investigate the relative cytotoxic effects of contact lens multipurpose solutions on cultured crystalline lenses.Methods: A comparison of the fluorescence emission levels of cultured bovine lenses as affected by three hour experimental exposure to three contact lens multipurpose solutions (COMPLETE Moisture Plus, AMO; OPTI-FREE Express, Alcon; and ReNu MultiPlus, Bausch & Lomb was carried out. The pre- and post-exposure fluorescence levels of the lenses were obtained and values were compared to baseline and control measurements.Results: The solutions yielded varying degrees of cytotoxicity, demonstrating significant (p < 0.01 reversible reduction of cellular viability levels of the cultured crystalline lenses as revealed by the degree of fluorescence emissions in the following order (OPTI-FREE Express > ReNu MultiPlus > COMPLETE MoisturePlus multi-purpose solutionsConclusions: The results show that OPTI-FREE Express and ReNu MultiPlus solutions exhibited more cytotoxic effect compared to COMPLETE MoisturePlus solution. The findings support reportsfrom previous clinical and laboratory studies. These results suggest that the in vitro approach herein presented would be a valuable system for relatively inexpensive and repeatable laboratory investigations of the possible ocular surface reactions of ophthal-mic solutions, cosmetics and pharmaceuticals at pre- and during commercial phases. 

  6. Growth and differentiation of human lens epithelial cells in vitro on matrix

    Science.gov (United States)

    Blakely, E. A.; Bjornstad, K. A.; Chang, P. Y.; McNamara, M. P.; Chang, E.; Aragon, G.; Lin, S. P.; Lui, G.; Polansky, J. R.

    2000-01-01

    PURPOSE: To characterize the growth and maturation of nonimmortalized human lens epithelial (HLE) cells grown in vitro. METHODS: HLE cells, established from 18-week prenatal lenses, were maintained on bovine corneal endothelial (BCE) extracellular matrix (ECM) in medium supplemented with basic fibroblast growth factor (FGF-2). The identity, growth, and differentiation of the cultures were characterized by karyotyping, cell morphology, and growth kinetics studies, reverse transcription-polymerase chain reaction (RT-PCR), immunofluorescence, and Western blot analysis. RESULTS: HLE cells had a male, human diploid (2N = 46) karyotype. The population-doubling time of exponentially growing cells was 24 hours. After 15 days in culture, cell morphology changed, and lentoid formation was evident. Reverse transcription-polymerase chain reaction (RT-PCR) indicated expression of alphaA- and betaB2-crystallin, fibroblast growth factor receptor 1 (FGFR1), and major intrinsic protein (MIP26) in exponential growth. Western analyses of protein extracts show positive expression of three immunologically distinct classes of crystallin proteins (alphaA-, alphaB-, and betaB2-crystallin) with time in culture. By Western blot analysis, expression of p57(KIP2), a known marker of terminally differentiated fiber cells, was detectable in exponential cultures, and levels increased after confluence. MIP26 and gamma-crystallin protein expression was detected in confluent cultures, by using immunofluorescence, but not in exponentially growing cells. CONCLUSIONS: HLE cells can be maintained for up to 4 months on ECM derived from BCE cells in medium containing FGF-2. With time in culture, the cells demonstrate morphologic characteristics of, and express protein markers for, lens fiber cell differentiation. This in vitro model will be useful for investigations of radiation-induced cataractogenesis and other studies of lens toxicity.

  7. Treatment of dystrophic calcification on a silicone intraocular lens with pars plana vitrectomy

    Directory of Open Access Journals (Sweden)

    Mehta N

    2014-07-01

    Full Text Available Nitish Mehta,1 Roger A Goldberg,2 Chirag P Shah21University of Massachusetts Medical School, Worcester, MA, USA; 2Department of Retina, Ophthalmic Consultants of Boston, Boston, Massachusetts, USAPurpose: Dense, vision-obscuring calcification on the posterior aspect of silicone intraocular lenses (IOLs is often not amenable to neodymium:yttrium-aluminum-garnet capsulotomy, and, in prior reports, has required IOL exchange. We report the successful removal of dense calcium deposition on the posterior surface of a three-piece silicone lens using pars plana vitrectomy (PPV.Materials and methods: A 23-gauge PPV was performed using the Stellaris® vitrectomy system. A light pipe was used to retroilluminate the IOL, and a dense fibrous tissue setting with a low cut-rate and high aspiration rate was able to clear the visual axis of the dystrophic calcification without damaging the IOL optic.Results: Visual acuity improved from 20/100 to 20/25.Conclusion: Small-gauge PPV may be utilized to remove dense dystrophic calcium deposits on the lens surface in lieu of IOL exchange. Keywords: cataract surgery, technique, Nd:YAG capsulotomy, IOL exchange

  8. A 100 m/320 Gbps SDM FSO link with a doublet lens scheme

    Science.gov (United States)

    Li, Chung-Yi; Lu, Hai-Han; Lu, Ting-Chien; Wu, Chang-Jen; Chu, Chien-An; Lin, Hung-Hsien; Cheng, Ming-Te

    2016-07-01

    A 100 m/320 Gbps space-division-multiplexing (SDM) free-space optical (FSO) link with a doublet lens scheme is proposed and experimentally demonstrated. The transmission capacity of FSO links is increased significantly by the SDM topology, and the transmission distance of FSO links is greatly extended by the doublet lens scheme. An FSO link of eight channels over a 100 m free-space link with a total transmission rate of 320 Gbps (40 Gbps/λ  ×  8λ  =  320 Gbps) is achieved. With the assistance of a low noise amplifier (LNA) and clock/data recovery (CDR) at the receiving site, a good bit error rate (BER) performance and a clear eye diagram are obtained at 100 m/320 Gbps. The proposed 100 m/320 Gbps SDM FSO link is shown to be a notable option to provide the advantages of long transmission distances and high transmission rates for optical wireless communications.

  9. Cx43, ZO-1, alpha-catenin and beta-catenin in cataractous lens epithelial cells

    Indian Academy of Sciences (India)

    Anshul I Arora; Kaid Johar; Devarshi U Gajjar; Darshini A Ganatra; Forum B Kayastha; Anuradha K Pal; Alpesh R Patel; Rajkumar S; Abhay R Vasavada

    2012-12-01

    Specimens of the anterior lens capsule with an attached monolayer of lens epithelial cells (LECs) were obtained from patients (=52) undergoing cataract surgery. Specimens were divided into three groups based on the type of cataract: nuclear cataract, cortical cataract and posterior subcapsular cataract (PSC). Clear lenses (=11) obtained from donor eyes were used as controls. Expression was studied by immunofluorescence, real-time PCR and Western blot. Statistical analysis was done using the student’s -test. Immunofluorescence results showed punctate localization of Cx43 at the cell boundaries in controls, nuclear cataract and PSC groups. In the cortical cataract group, cytoplasmic pools of Cx43 without any localization at the cell boundaries were observed. Real-time PCR results showed significant up-regulation of Cx43 in nuclear and cortical cataract groups. Western blot results revealed significant increase in protein levels of Cx43 and significant decrease of ZO-1 in all three cataract groups. Protein levels of alpha-catenin were decreased significantly in nuclear and cortical cataract group. There was no significant change in expression of beta-catenin in the cataractous groups. Our findings suggest that ZO-1 and alpha-catenin are important for gap junctions containing Cx43 in the LECs. Alterations in cell junction proteins may play a role during formation of different types of cataract.

  10. Study of Gravitational Lens Chromaticity from Ground-based Narrow Band Photometry

    CERN Document Server

    Mosquera, Ana M; Mediavilla, Evencio; Kochanek, Christopher S

    2010-01-01

    We present observations of wavelength-dependent flux ratios for 4 gravitational lens systems (SDSS~J1650+4251, HE~0435$-$1223, FBQ 0951+2635, and Q~0142$-$100) obtained with the Nordic Optical telescope (NOT). The use of narrow band photometry, as well as the excellent seeing conditions during the observations, allow us to set good baselines to study their chromatic behavior. For SDSS~J1650+4251 we determine the extinction curve of the dust in the $z_L=0.58$ lens galaxy, and find that the 2175 \\AA \\ feature is absent. In the case of HE~0435$-$1223 we clearly detect chromatic microlensing. This allows us to estimate the wavelength dependent size of the accretion disk. We found an R-band disk size of $r^{R}_s=13\\pm5$ light days for a linear prior on $r^{R}_s$ and of $r^{R}_s=7\\pm6$ light days for a logarithmic prior. For a power law size-wavelength scaling of $r_s\\propto\\lambda^{p}$, we were able to constrain the value of the exponent to $p=1.3\\pm0.3$ for both $r^{R}_s$ priors, which is in agreement with the te...

  11. Molecular Characterization of Clear Cell Lesions of Head and Neck.

    Science.gov (United States)

    Jain, Anshi; Shetty, Devi Charan; Juneja, Saurabh; Narwal, Nidhi

    2016-05-01

    The salivary glands, oral mucosa and jaws constitute a group of lesions which are heterogeneous in nature and are odontogenic, salivary or metastatic in origin. This group of tumours is termed as Clear Cell Tumours. Fixation artifacts are one of the most important reasons for the cell to appear clear but clearing of cells may also result from cytoplasmic accumulation of water, presence of glycogen within the cell, intermediate filaments, immature zymogen granules, or a paucity of cellular organelles. Clear cell Odontogenic neoplasms predominantly include odontogenic carcinoma, ameloblastoma and calcifying epithelial odontogenic tumour. Clear cell tumours of salivary gland origin are almost invariably malignant in nature but they do include two benign lesions. Very frequently, surgical pathologist encounters clear cells in many malignant neoplasms, the nature and sources of which are undetermined on the basis of conventional histopathology. This review will selectively discuss the clinicopathological features of neoplasms which at times may pose a diagnostic challenge and dilemma due to clear cell changes. PMID:27437379

  12. Scattered radiation risk to the lens of the eyes for staff involved in using mobile C-arm fluoroscopy unit: Which position is riskiest?

    International Nuclear Information System (INIS)

    Cataractogenesis is something to be concerned by radiologist and radiographer who work extensively in fluoroscopy. The increasing use of fluoroscopy or interventional fluoroscopy has to come with safety awareness on scattered radiation risk for staff performing the procedure. This study is looking into the radiation risk to the lens of the eyes for staff involved in fluoroscopy using the mobile C-arm fluoroscopy unit. The Toshiba SXT-1000A and Alderson Rando phantom were used in this study. Based on the results, it is found clearly that over couch (OC) procedure is riskier than under couch (UC) procedure. The cathode bound area is clearly riskier than anode bound area especially for UC procedure. More doses (at least +1,568 % of safest position) are received by the lens of the eyes for staff standing at the cathode bound area especially the position opposite to the x-ray tube

  13. Scattered radiation risk to the lens of the eyes for staff involved in using mobile C-arm fluoroscopy unit: Which position is riskiest?

    Science.gov (United States)

    Salleh, H.; Samat, S. B.; Matori, M. K.; Isa, M. J. M.

    2015-09-01

    Cataractogenesis is something to be concerned by radiologist and radiographer who work extensively in fluoroscopy. The increasing use of fluoroscopy or interventional fluoroscopy has to come with safety awareness on scattered radiation risk for staff performing the procedure. This study is looking into the radiation risk to the lens of the eyes for staff involved in fluoroscopy using the mobile C-arm fluoroscopy unit. The Toshiba SXT-1000A and Alderson Rando phantom were used in this study. Based on the results, it is found clearly that over couch (OC) procedure is riskier than under couch (UC) procedure. The cathode bound area is clearly riskier than anode bound area especially for UC procedure. More doses (at least +1,568 % of safest position) are received by the lens of the eyes for staff standing at the cathode bound area especially the position opposite to the x-ray tube.

  14. Scattered radiation risk to the lens of the eyes for staff involved in using mobile C-arm fluoroscopy unit: Which position is riskiest?

    Energy Technology Data Exchange (ETDEWEB)

    Salleh, H.; Matori, M. K.; Isa, M. J. M. [Agensi Nuklear Malaysia, Bangi, 43000 Kajang, Selangor (Malaysia); Samat, S. B. [Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor (Malaysia)

    2015-09-25

    Cataractogenesis is something to be concerned by radiologist and radiographer who work extensively in fluoroscopy. The increasing use of fluoroscopy or interventional fluoroscopy has to come with safety awareness on scattered radiation risk for staff performing the procedure. This study is looking into the radiation risk to the lens of the eyes for staff involved in fluoroscopy using the mobile C-arm fluoroscopy unit. The Toshiba SXT-1000A and Alderson Rando phantom were used in this study. Based on the results, it is found clearly that over couch (OC) procedure is riskier than under couch (UC) procedure. The cathode bound area is clearly riskier than anode bound area especially for UC procedure. More doses (at least +1,568 % of safest position) are received by the lens of the eyes for staff standing at the cathode bound area especially the position opposite to the x-ray tube.

  15. Clear-PEM, a dedicated PET camera for mammography

    CERN Document Server

    Lecoq, P

    2002-01-01

    Preliminary results suggest that Positron Emission Mammography (PEM) can offer a noninvasive method for the diagnosis of breast cancer. Metabolic images from PEM contain unique information not available from conventional morphologic imaging techniques and aid in expeditiously establishing the diagnosis of cancer. A dedicated machine seems to offer better perspectives in terms of position resolution and sensitivity. This paper describes the concept of Clear-PEM, the system presently developed by the Crystal Clear Collaboration at CERN for an evaluation of this approach. This device is based on new crystals introduced by the Crystal Clear as well as on modern data acquisition techniques developed for the large experiments in high energy physics experiments.

  16. Monitoring the eye lens: which dose quantity is adequate?

    International Nuclear Information System (INIS)

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. The question of which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens arises from this situation. While in many countries dosemeters calibrated in terms of the dose equivalent quantity Hp(0.07) have been seen as being adequate for monitoring the dose to the eye lens, this might be questionable in the case of reduced dose limits and, thus, it may become necessary to use the dose equivalent quantity Hp(3) for this purpose. To discuss this question, the dose conversion coefficients for the equivalent dose of the eye lens (in the following eye lens dose) were determined for realistic photon and beta radiation fields and compared with the values of the corresponding conversion coefficients for the different operational quantities. The values obtained lead to the following conclusions: in radiation fields where most of the dose comes from photons, especially x-rays, it is appropriate to use dosemeters calibrated in terms of Hp(0.07) on a slab phantom, while in other radiation fields (dominated by beta radiation or unknown contributions of photon and beta radiation) dosemeters calibrated in terms of Hp(3) on a slab phantom should be used. As an alternative, dosemeters calibrated in terms of Hp(0.07) on a slab phantom could also be used; however, in radiation fields containing beta radiation with the end point energy near 1 MeV, an overestimation of the eye lens dose by up to a factor of 550 is possible.

  17. Extraction process

    International Nuclear Information System (INIS)

    A process is described for extracting at least two desired constituents from a mineral, using a liquid reagent which produces the constituents, or compounds thereof, in separable form and independently extracting those constituents, or compounds. The process is especially valuable for the extraction of phosphoric acid and metal values from acidulated phosphate rock, the slurry being contacted with selective extractants for phosphoric acid and metal (e.g. uranium) values. In an example, uranium values are oxidized to uranyl form and extracted using an ion exchange resin. (U.K.)

  18. The Lens Staring You in the Face

    Science.gov (United States)

    vachon, R. W.

    2012-12-01

    When you are embedded in the minutia of a science, you and your collaborators don't need to be convinced that there are benefits to investigating your precise science. You are intrinsically invested. In fact, we spend so much time around each other that we create our own language. So many acronyms that we come to take for granted and topic relevant words, like "fractionate", are not common parlance. This is the case with any specialization, but when it becomes second nature to communicate your work with these norms, transmission breaks down, people tune out, and some audiences become frustrated. Media can cushion this separation, but what do you do when you are the one in front of the camera, and clarity and impact of a concept rests on your shoulders? Just as writing a peer review paper is an acquired skill, so is communicating to the ones who pay many of our salaries, taxpayers. Over the past three years I have worked intimately with publishers, networks and university outreach programs to refine my approach to communicating scientific knowledge to particular audiences. The road has positioned me as interviewee, motivational speaker for science, technology, engineering and math (STEM) in middle and high schools, and educational video series host. Media has their own standards. Personality and enthusiasm may be just as important as the journal into which your findings were published. This presentation will emphasize the audience-adjustable tenants that have stood the test of time to result in effective video communication. Additionally, preparation for and execution of different roles in front of the lens will be discussed.Communicating concepts on video

  19. LensPerfect Analysis of Abell 1689

    Science.gov (United States)

    Coe, Dan A.

    2007-12-01

    I present the first massmap to perfectly reproduce the position of every gravitationally-lensed multiply-imaged galaxy detected to date in ACS images of Abell 1689. This massmap was obtained using a powerful new technique made possible by a recent advance in the field of Mathematics. It is the highest resolution assumption-free Dark Matter massmap to date, with the resolution being limited only by the number of multiple images detected. We detect 8 new multiple image systems and identify multiple knots in individual galaxies to constrain a grand total of 168 knots within 135 multiple images of 42 galaxies. No assumptions are made about mass tracing light, and yet the brightest visible structures in A1689 are reproduced in our massmap, a few with intriguing positional offsets. Our massmap probes radii smaller than that resolvable in current Dark Matter simulations of galaxy clusters. And at these radii, we observe slight deviations from the NFW and Sersic profiles which describe simulated Dark Matter halos so well. While we have demonstrated that our method is able to recover a known input massmap (to limited resolution), further tests are necessary to determine the uncertainties of our mass profile and positions of massive subclumps. I compile the latest weak lensing data from ACS, Subaru, and CFHT, and attempt to fit a single profile, either NFW or Sersic, to both the observed weak and strong lensing. I confirm the finding of most previous authors, that no single profile fits extremely well to both simultaneously. Slight deviations are revealed, with the best fits slightly over-predicting the mass profile at both large and small radius. Our easy-to-use software, called LensPerfect, will be made available soon. This research was supported by the European Commission Marie Curie International Reintegration Grant 017288-BPZ and the PNAYA grant AYA2005-09413-C02.

  20. New trends in intraocular lens imaging

    Science.gov (United States)

    Millán, María S.; Alba-Bueno, Francisco; Vega, Fidel

    2011-08-01

    As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the

  1. Novel fabrication technique of hybrid structure lens array for 3D images

    Science.gov (United States)

    Lee, Junsik; Kim, Junoh; Kim, Cheoljoong; Shin, Dooseub; Koo, Gyohyun; Won, Yong Hyub

    2016-03-01

    Tunable liquid lens arrays can produce three dimensional images by using electrowetting principle that alters surface tensions by applying voltage. This method has advantages of fast response time and low power consumption. However, it is challenging to fabricate a high fill factor liquid lens array and operate three dimensional images which demand high diopter. This study describes a hybrid structure lens array which has not only a liquid lens array but a solid lens array. A concave-shape lens array is unavoidable when using only the liquid lens array and some voltages are needed to make the lens flat. By placing the solid lens array on the liquid lens array, initial diopter can be positive. To fabricate the hybrid structure lens array, a conventional lithographic process in semiconductor manufacturing is needed. A negative photoresist SU-8 was used as chamber master molds. PDMS and UV adhesive replica molding are done sequentially. Two immiscible liquids, DI water and dodecane, are injected in the fabricated chamber, followed by sealing. The fabricated structure has a 20 by 20 pattern of cylindrical shaped circle array and the aperture size of each lens is 1mm. The thickness of the overall hybrid structure is about 2.8mm. Hybrid structure lens array has many advantages. Solid lens array has almost 100% fill factor and allow high efficiency. Diopter can be increased by more than 200 and negative diopter can be shifted to the positive region. This experiment showed several properties of the hybrid structure and demonstrated its superiority.

  2. Flocculants application for precipitation and separation of proteins from Lens culinaris cv. Tina

    Directory of Open Access Journals (Sweden)

    Barbara Baraniak

    2009-06-01

    Full Text Available Background. Lentil (Lens culinaris is an important crop in many developing countries. Usefulness of protein isolates in the human nutrition and animal feeding have been also studied. Improvement of protein precipitation and fractionation efficiency by using different flocculants was the aim of this study. Material and methods. The polyelectrolytes Magnafloc LT-22 and Magnafloc LT-25 were tested in the process of coagulation and fractionation of protein from lentil protein extracts. Proteins were extracted from flour with 0.5 M NaCl in the 50 mM Tris-HCl buffer pH 7.5 and 2 mM NaOH at ratio 1:10. Protein were coagulated at different pH (6, 5, 4, 3 using flocculants in three different concentration 0.1, 0.3 and 0.5%. Samples were analyzed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Results. Influence of extraction medium on the yield and quality of protein was visible. In all studied cases proteins were the most effective precipitated with Magnofloc LT-25. Application of different pH condition for coagulation caused fractionation of lentil protein. Gel electrophoresis of protein of all studied samples showed different molecular weight subunit patterns ranging from 8 to 102 kDa. Conclusions. Using of flocculants as coagulating factors allows obtaining a high concentrated protein isolates, however the yields of flocculation were determined by different extraction systems, concentration of flocculants and pH condition of process.

  3. Identification and Ultrastructural Characterization of a Novel Nuclear Degradation Complex in Differentiating Lens Fiber Cells.

    Science.gov (United States)

    Costello, M Joseph; Brennan, Lisa A; Mohamed, Ashik; Gilliland, Kurt O; Johnsen, Sönke; Kantorow, Marc

    2016-01-01

    An unresolved issue in structural biology is how the encapsulated lens removes membranous organelles to carry out its role as a transparent optical element. In this ultrastructural study, we establish a mechanism for nuclear elimination in the developing chick lens during the formation of the organelle-free zone. Day 12-15 chick embryo lenses were examined by high-resolution confocal light microscopy and thin section transmission electron microscopy (TEM) following fixation in 10% formalin and 4% paraformaldehyde, and then processing for confocal or TEM as described previously. Examination of developing fiber cells revealed normal nuclei with dispersed chromatin and clear nucleoli typical of cells in active ribosome production to support protein synthesis. Early signs of nuclear degradation were observed about 300 μm from the lens capsule in Day 15 lenses where the nuclei display irregular nuclear stain and prominent indentations that sometimes contained a previously undescribed macromolecular aggregate attached to the nuclear envelope. We have termed this novel structure the nuclear excisosome. This complex by confocal is closely adherent to the nuclear envelope and by TEM appears to degrade the outer leaflet of the nuclear envelope, then the inner leaflet up to 500 μm depth. The images suggest that the nuclear excisosome separates nuclear membrane proteins from lipids, which then form multilamellar assemblies that stain intensely in confocal and in TEM have 5 nm spacing consistent with pure lipid bilayers. The denuded nucleoplasm then degrades by condensation and loss of structure in the range 600 to 700 μm depth producing pyknotic nuclear remnants. None of these stages display any classic autophagic vesicles or lysosomes associated with nuclei. Uniquely, the origin of the nuclear excisosome is from filopodial-like projections of adjacent lens fiber cells that initially contact, and then appear to fuse with the outer nuclear membrane. These filopodial

  4. Molecular Air Data Clear Air Turbulence Sensor: MADCAT Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Clear air turbulence (CAT), often referred to as "air pockets," is attributed to Kelvin-Helmholtz instabilities at altitudes generally above 18,000ft, often in the...

  5. Molecular Air Data Clear Air Turbulence Sensor: MADCAT Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Clear air turbulence (CAT), often referred to as "air pockets," is attributed to Kelvin-Helmholtz instabilities at altitudes usually above 18,000ft, often without...

  6. Reconstruction of Clear-PEM data with STIR

    CERN Document Server

    Martins, M V; Rodrigues, P; Trindade, A; Oliveira, N; Correia, M; Cordeiro, H; Ferreira, N C; Varela, J; Almeida, P

    2006-01-01

    The Clear-PEM scanner is a device based on planar detectors that is currently under development within the Crystal Clear Collaboration, at CERN. The basis for 3D image reconstruction in Clear-PEM is the software for tomographic image reconstruction (STIR). STIR is an open source object-oriented library that efficiently deals with the 3D positron emission tomography data sets. This library was originally designed for the traditional cylindrical scanners. In order to make its use compatible with planar scanner data, new functionalities were introduced into the library's framework. In this work, Monte Carlo simulations of the Clear-PEM scanner acquisitions were used as input for image reconstruction with the 3D OSEM algorithm available in STIR. The results presented indicate that dual plate PEM data can be accurately reconstructed using the enhanced STIR framework.

  7. CBFS: high performance feature selection algorithm based on feature clearness.

    Directory of Open Access Journals (Sweden)

    Minseok Seo

    Full Text Available BACKGROUND: The goal of feature selection is to select useful features and simultaneously exclude garbage features from a given dataset for classification purposes. This is expected to bring reduction of processing time and improvement of classification accuracy. METHODOLOGY: In this study, we devised a new feature selection algorithm (CBFS based on clearness of features. Feature clearness expresses separability among classes in a feature. Highly clear features contribute towards obtaining high classification accuracy. CScore is a measure to score clearness of each feature and is based on clustered samples to centroid of classes in a feature. We also suggest combining CBFS and other algorithms to improve classification accuracy. CONCLUSIONS/SIGNIFICANCE: From the experiment we confirm that CBFS is more excellent than up-to-date feature selection algorithms including FeaLect. CBFS can be applied to microarray gene selection, text categorization, and image classification.

  8. Visual and Refractive Outcomes of a Toric Presbyopia-Correcting Intraocular Lens

    Science.gov (United States)

    Epitropoulos, Alice T.

    2016-01-01

    Purpose. To evaluate outcomes in astigmatic patients implanted with the Trulign (Bausch + Lomb) toric presbyopia-correcting intraocular lens (IOL) during cataract surgery in a clinical practice setting. Methods. Retrospective study in 40 eyes (31 patients) that underwent cataract extraction and IOL implantation in a procedure using intraoperative wavefront aberrometry guidance (ORA system). Endpoints included uncorrected visual acuity (VA), reduction in refractive cylinder, accuracy to target, axis orientation, and safety. Results. At postoperative month 1, refractive cylinder was ≤0.50 D in 97.5% of eyes (≤1.00 D in 100%), uncorrected distance VA was 20/25 or better in 95%, uncorrected intermediate VA was 20/25 or better in 95%, and uncorrected near VA was 20/40 (J3 equivalent) or better in 92.5%. Manifest refraction spherical equivalent was within 1.00 D of target in 95% of eyes and within 0.50 D in 82.5%. Lens rotation was <5° and best-corrected VA was 20/25 or better in all eyes. Conclusion. The IOL effectively reduced refractive cylinder and provided excellent uncorrected distance and intermediate vision and functional near vision. Refractive predictability and rotational stability were exceptional. Implantation of this toric presbyopia-correcting IOL using ORA intraoperative aberrometry provides excellent refractive and visual outcomes in a standard of care setting. PMID:26885382

  9. Imaging of aphakic intraocular lens with a slit-scanning tomography system

    Science.gov (United States)

    Oliveira, Cristina M.; Almeida, J. B.; Franco, S.

    2011-05-01

    Nowadays, cataract extraction with IOL implantation aims not only to restore the crystalline lens' transparency, but also to improve patients' retinal image quality. The refractive outcome and visual quality in pseudophakic eyes is mainly determined by the combination of corneal and internal optics resulting from the implanted IOLs. The optical function of the IOLs depends on its position in the eye. The IOL distance to the corneal apex determines the optical power needed for optical correction. In this paper it is described the usage of a slit-scanning imaging system to determine IOL positioning. Through the projection of the light from a slit onto the eye, this tomography system allows to acquire multiple sections of the anterior eye segment, at different meridians. The developed system's software corrects geometric and optical distortion of the images and provides 3-dimentional models of the eye's structures from the 2-dimensional sections. With this noninvasive technique, cross-sectional images of an eye with an aphakic IOL were obtained in order to reconstruct its 3- dimensional model of the lens and assess its position in the anterior segment camera.

  10. Clearing Barter Exchange Markets: Kidney Exchange and Beyond

    OpenAIRE

    Glorie, Kristiaan

    2014-01-01

    markdownabstract__Abstract__ Advanced computer assisted markets, otherwise known as smart markets, are becoming an important part of our modern society. This dissertation considers smart barter exchange markets, which enable people to trade a wide range of goods: from shifts, to houses, to kidneys. Centralized and computerized clearing is what makes these markets ‘smart’. The market clearing problem is to match demand and supply so as to maximize the gains of trade. Trades, in this regard, ne...

  11. A Spectroscopically Confirmed Double Source Plane Lens System in the Hyper Suprime-Cam Subaru Strategic Program

    CERN Document Server

    Tanaka, Masayuki; More, Anupreeta; Dezuka, Arsha; Egami, Eiichi; Oguri, Masamune; Suyu, Sherry H; Sonnenfeld, Alessandro; Higuchi, Ryou; Komiyama, Yutaka; Miyazaki, Satoshi; Onoue, Masafusa; Oyamada, Shuri; Utsumi, Yousuke

    2016-01-01

    We report the serendipitous discovery of HSC J142449-005322, a double source plane lens system in the Hyper Suprime-Cam Subaru Strategic Program. We dub the system Eye of Horus. The lens galaxy is a very massive early-type galaxy with stellar mass of ~7x10^11 Msun located at z_L=0.795. The system exhibits two arcs/rings with clearly different colors, including several knots. We have performed spectroscopic follow-up observations of the system with FIRE on Magellan. The outer ring is confirmed at z_S2=1.988 with multiple emission lines, while the inner arc and counterimage is confirmed at z_S1=1.302. This makes it the first double source plane system with spectroscopic redshifts of both sources. Interestingly, redshifts of two of the knots embedded in the outer ring are found to be offset by delta_z=0.002 from the other knots, suggesting that the outer ring consists of at least two distinct components in the source plane. We perform lens modeling with two independent codes and successfully reproduce the main f...

  12. [Glycation of lens proteins in diabetes and its non-invasive assessment - first experience in the Czech Republic].

    Science.gov (United States)

    Škrha, Jan; Šoupal, Jan; Prázný, Martin; Škrha, Jan

    2015-04-01

    Advanced glycation end-products (AGEs) play a crucial role in the pathogenesis of diabetes and its complications. Their accumulation in the lens reflects total glycation rate in the human body. Recently, a new confocal biomicroscope ClearPath DS-120 quickly measuring lens autofluorescence (LAF) has been developed. Our pilot study included 69 patients with diabetes and 49 healthy controls, in all subject LAF was measured and compared with skin autofluorescence (SAF) assessed by AGE-Reader. Both LAF (T1DM: 0,27 ± 0,09; T2DM: 0,22 ± 0,06; controls: 0,17 ± 0,04 AU; p glycated hemoglobin (HbA1c) was rather poor, since HbA1c cannot wholly reflect long-term glycation process. Lens autofluorescence could be a robust marker of long-term diabetes control predicting future complication risks. However, confirmation of such hypothesis will need other and long-term clinical studies.

  13. [Glycation of lens proteins in diabetes and its non-invasive assessment - first experience in the Czech Republic].

    Science.gov (United States)

    Škrha, Jan; Šoupal, Jan; Prázný, Martin; Škrha, Jan

    2015-04-01

    Advanced glycation end-products (AGEs) play a crucial role in the pathogenesis of diabetes and its complications. Their accumulation in the lens reflects total glycation rate in the human body. Recently, a new confocal biomicroscope ClearPath DS-120 quickly measuring lens autofluorescence (LAF) has been developed. Our pilot study included 69 patients with diabetes and 49 healthy controls, in all subject LAF was measured and compared with skin autofluorescence (SAF) assessed by AGE-Reader. Both LAF (T1DM: 0,27 ± 0,09; T2DM: 0,22 ± 0,06; controls: 0,17 ± 0,04 AU; p glycated hemoglobin (HbA1c) was rather poor, since HbA1c cannot wholly reflect long-term glycation process. Lens autofluorescence could be a robust marker of long-term diabetes control predicting future complication risks. However, confirmation of such hypothesis will need other and long-term clinical studies. PMID:25894266

  14. Development of a Laue lens for nuclear astrophysics

    International Nuclear Information System (INIS)

    The Laue lenses we study focuses in the domain of 0.1-1 MeV thanks to Bragg diffraction in the volume of a large number of small crystal tiles. The focal length of a typical Laue lens system is of the order of 100 m. This requirement calls for two formation flying satellites maintaining lens and detector at the focal distance. The major breakthrough of Laue lenses is to decouple collecting area from detector area. Concentrating a signal from the large area of a Laue lens onto a small focal spot dramatically increases the signal over background ratio with respect to present technologies. Here is the reason for the long awaited leap in sensitivity. The objective of the present thesis was to improve the concept, finding viable technical solutions towards a future space mission. Two aspects of the lens development have been highlighted in this thesis: the first one is an analytical model of the lens that is used to calculate and improve the performance of a certain configuration, the second aspect concerns the search and the characterization of diffracting media of interest. The lens model developed relies on a fast semi-analytical simulation library, permitting to build several design- and optimisation-tools. For the configuration of a given lens, this code computes the resulting effective area and point spread function in a handful of seconds. The model helps finding lens configurations (mass, pack ratio of the lens rings,...) which are automatically refined to match with effective area and energy coverage constraints. These tools have been used to investigate various design aspects, such as the influence of focal length, size, mosaic spread, structure and materials of crystals, etc... The central evaluation criterion in the model is a figure of merit, based on the compactness of the focal spot and the intensity of the collected signal. The second part of this work addresses the actual search and characterization of crystals potentially interesting for Laue lenses

  15. Lens density tracking in mice by Scheimpflug imaging.

    Science.gov (United States)

    Puk, Oliver; de Angelis, Martin Hrabĕ; Graw, Jochen

    2013-08-01

    Scheimpflug imaging has recently been established for in vivo imaging of the anterior eye segment and quantitative determination of lens transparency in the mouse. This enables more effective investigations of cataract formation with the mouse model, including longitudinal studies. In order to enable recognition of disease-associated irregularities, we performed Scheimpflug measurements with the common laboratory inbred lines C57BL/6J, C3HeB/FeJ, FVB/NCrl, BALB/cByJ, and 129/SvJ in a period between 2 and 12 months of age. C57BL/6J mice showed lowest mean lens densities during the test period. Progressive cortical lens opacification was generally observed, with the earliest onset in C57BBL/6J, C3HeB/FeJ, and 129/SvJ, between 2 and 6 months after birth. Moreover, lenses of these inbred lines developed nuclear opacities. Calculated mean lens density significantly increased between 6 and 12 months of age in all inbred strains except 129/SvJ. Lens densities (and the corresponding standard deviations) of FVB/NCrl and 129/SvJ increased most likely because of differences in the genetic background. Albinism as confounder might be excluded since the albino Balb/cByJ mice are more similar to the C57BL/6J or C3Heb/FeJ mice. We further identified strain-specific anterior lens opacities (C57BL/6J) and cloudy corneal lesions (C57BL/6J, FVB/NCrl, and BALB/cByJ) at later stages. In conclusion, our results indicate that there are lifelong opacification processes in the mouse lens. The highest lens transparency and a dark coat color, which prevents interference from light reflections, make mice with the C57BL/6J background most suitable for cataract research by Scheimpflug imaging. We show that lens densitometry by Scheimpflug imaging in mouse eyes can resolve differences of less than 1 %, making it possible to detect differences in cataract development in different mouse strains, even if they are small. PMID:23929037

  16. Beam Dynamics in an Electron Lens with the Warp Particle-in-cell Code

    CERN Document Server

    Stancari, Giulio; Redaelli, Stefano

    2014-01-01

    Electron lenses are a mature technique for beam manipulation in colliders and storage rings. In an electron lens, a pulsed, magnetically confined electron beam with a given current-density profile interacts with the circulating beam to obtain the desired effect. Electron lenses were used in the Fermilab Tevatron collider for beam-beam compensation, for abort-gap clearing, and for halo scraping. They will be used in RHIC at BNL for head-on beam-beam compensation, and their application to the Large Hadron Collider for halo control is under development. At Fermilab, electron lenses will be implemented as lattice elements for nonlinear integrable optics. The design of electron lenses requires tools to calculate the kicks and wakefields experienced by the circulating beam. We use the Warp particle-in-cell code to study generation, transport, and evolution of the electron beam. For the first time, a fully 3-dimensional code is used for this purpose.

  17. Goat′s eye integrated with a human cataractous lens: A training model for phacoemulsification

    Directory of Open Access Journals (Sweden)

    Sabyasachi Sengupta

    2015-01-01

    Full Text Available A relatively simple and inexpensive technique to train surgeons in phacoemulsification using a goat′s eye integrated with a human cataractous nucleus is described. The goat′s eye is placed on a bed of cotton within the lumen of a cylindrical container. This is then mounted on a rectangular thermocol so that the limbus is presented at the surgical field. After making a clear corneal entry with a keratome, the trainer makes a 5-5.5 mm continuous curvilinear capsulorhexis in the anterior lens capsule, creates a crater of adequate depth in the cortex and inserts the human nucleus within this crater in the goat′s capsular bag. The surgical wound is sutured, and the goat′s eye is ready for training. Creating the capsulorhexis with precision and making the crater of adequate depth to snugly accommodate the human nucleus are the most important steps to prevent excessive wobbling of the nucleus while training.

  18. Global horizontal irradiance clear sky models : implementation and analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua S.; Hansen, Clifford W.; Reno, Matthew J.

    2012-03-01

    Clear sky models estimate the terrestrial solar radiation under a cloudless sky as a function of the solar elevation angle, site altitude, aerosol concentration, water vapor, and various atmospheric conditions. This report provides an overview of a number of global horizontal irradiance (GHI) clear sky models from very simple to complex. Validation of clear-sky models requires comparison of model results to measured irradiance during clear-sky periods. To facilitate validation, we present a new algorithm for automatically identifying clear-sky periods in a time series of GHI measurements. We evaluate the performance of selected clear-sky models using measured data from 30 different sites, totaling about 300 site-years of data. We analyze the variation of these errors across time and location. In terms of error averaged over all locations and times, we found that complex models that correctly account for all the atmospheric parameters are slightly more accurate than other models, but, primarily at low elevations, comparable accuracy can be obtained from some simpler models. However, simpler models often exhibit errors that vary with time of day and season, whereas the errors for complex models vary less over time.

  19. Coastal sediment elevation change following anthropogenic mangrove clearing

    Science.gov (United States)

    Hayden, Heather L.; Granek, Elise F.

    2015-11-01

    Coastal mangrove forests along tropical shorelines serve as an important interface between land and sea. They provide a physical buffer protecting the coastline from erosion and act as sediment "traps" catching terrestrial sediment, thus preventing smothering of subtidal coral reefs. Coastal development that removes mangrove habitat may impact adjacent nearshore coral reefs through sedimentation and nutrient loading. We examined differences in sediment elevation change between patches of open-coast intact and anthropogenically cleared red mangroves (Rhizophora mangle) on the east side of Turneffe Atoll, Belize, to quantify changes following mangrove clearing. Samples were collected over a 24 month period at five study sites, each containing paired intact (+mangrove) and cleared (-mangrove) plots. Five sediment elevation pins were deployed in each plot: behind areas cleared of mangroves (-mangrove) and behind adjacent intact mangroves (+mangrove). Sediment elevation increased at intact mangrove sites (M = +3.83 mm, SE = 0.95) whereas cleared mangrove areas suffered elevation loss (M = -7.30 mm, SE = 3.38). Mangroves inshore of partial or continuous gaps in the adjacent fringing reefs had higher rates of elevation loss (M = -15.05 mm) than mangroves inshore of continuous fringing reefs (M = -1.90 mm). Our findings provide information on potential effects of mangrove clearing and the role of offshore habitat characteristics on coastal sediment trapping and maintenance of sediment elevation by mangroves. With implications for coastline capacity to adjust to sea level rise, these findings are relevant to management of coastal fringing mangrove forests across the Caribbean.

  20. Comparison of visual outcomes after implantation of diffractive trifocal toric intraocular lens and a diffractive apodized bifocal toric intraocular lens

    Science.gov (United States)

    Gundersen, Kjell Gunnar; Potvin, Rick

    2016-01-01

    Purpose The aim of this study was to compare a new diffractive trifocal toric lens with an apodized diffractive bifocal toric lens in terms of refractive and visual acuity (VA) outcomes, including low-contrast VA (LCVA), as well as the patient’s visual function 3 months after implantation. Patients and methods This is a randomized prospective study involving bilateral implantation of a trifocal toric or a bifocal toric lens. At 3 months postoperatively, the subject’s vision was tested both uncorrected and with his/her best distance correction at: distance (4 m), intermediate (63 cm), and near (40 cm). Binocular defocus curves were measured with no correction and with the subject’s best distance correction in place. Quality of vision was measured using the National Eye Institute Visual Function Questionnaire. Results A total of 22 patients were enrolled (eleven in each group). There was no statistically significant difference in the absolute change in measured rotation between 1 month and 3 months postoperatively between the two intraocular lens (IOL) groups (P=0.98). At 3 months, the postoperative refraction and distance VA by eye were similar between groups. There was no statistically significant difference in the measured LCVA between groups (P=0.39). The defocus curve showed that at 67 cm, the trifocal toric lens had statistically significantly better VA when compared to the bifocal toric lens. There were no statistically significant differences by group for any of the National Eye Institute Visual Function Questionnaire scores (P>0.26 in all cases). Conclusion The trifocal toric IOL improved the intermediate vision without negatively impacting visual function and distance, near, or low-contrast VA when compared to a bifocal toric IOL. The toric component of the trifocal lens effectively reduced astigmatism and provided good rotational stability. PMID:27051269