WorldWideScience

Sample records for clasp device

  1. [Hand clasping--an overview].

    Science.gov (United States)

    Reiss, M

    1999-06-01

    The literature concerning the asymmetry clasping hands is reviewed based on 192 studies. This paper describes the incidence, sex differences, age differences and genetical problems including twinning. The incidence of left hand clasping ranges from 30% to 75% (mean 43%). The review confirms the so-called east-west-gradient and there is a predominance of the left type in Europe. Age and sex differences are only small. There is only a small relationship between hand clasping and handedness. 18 authors examined hand clasping in families and 4 in twins. The family data suggest that hand clasping may be under genetic control, yet it is clear that no simple genetic model for the inheritance can be applied. Both monozygotic and dizygotic twins show a low concordance and the R-R, R-L and L-L pairs in monozygotic and dizygotic twins are in binomial distribution. PMID:10483485

  2. Common LISP as Simulation Program (CLASP of Electronic Circuits

    Directory of Open Access Journals (Sweden)

    D. Cerny

    2011-12-01

    Full Text Available In this paper, an unusual and efficient usage of functional programming language Common LISP as simulation program (CLASP for electronic circuits is proposed. The principle of automatic self-modifying program has enabled complete freedom in definition of methods for optimized solution of any problem and speeding up the entire process of simulation. A new approach to program structure in electronic circuit simulator CLASP is described. The definition of simple electronic devices as resistor, voltage source and diode is given all together with description of their memory management in program CLASP. Other circuit elements can be easily defined in the same way. Simulation methods for electronic circuits as linear and nonlinear direct current analysis (DC are suggested. A comparison of performances of two different linear solvers (an original and the standard GNU GSL for circuit equations is demonstrated by an algorithm for automatic generation of huge circuits.

  3. Bending rigidity of composite resin coating clasps.

    Science.gov (United States)

    Ikebe, K; Kibi, M; Ono, T; Nokubi, T

    1993-12-01

    The purpose of this study is to examine the bending profiles of composite resin coating cast clasps. The cobalt-chromium alloy cast clasps were made using tapered wax pattern. Silane coupling method (Silicoater MD, Kulzer Co.) was used to attach composite resin to metal surface. The breakage and the bending rigidity of composite resin coating clasps were evaluated. Results were as follows: 1) After the repeated bending test to the tips of clasp arm at 10,000 times in 0.25 mm deflection, neither crack on composite resin surface nor separation at resin/metal interface was observed in any specimen. 2) There was no significant difference in the bending rigidity of clasp arms between before and after composite resin coating. From these results, it was demonstrated that the composite resin coating cast clasp was available in clinical cases and coating with composite resin had little influence on the bending rigidity of clasp arms. Therefore, it was suggested that our clasp designing and fabricating system to control the bending rigidity of clasp arms could be applied to composite resin coating clasps. PMID:8935086

  4. A New Clasp to Fix Partial Dentures

    Directory of Open Access Journals (Sweden)

    Saakyan М.Yu.

    2012-03-01

    Full Text Available A new clasp to fix small saddle prostheses was designed to improve the quality of prosthetic unilateral free-end saddle restoration. Unlike the known ones, the clasp can be adapted for clinical crowns of any height (particularly useful for low crowns as no standard elements are required to be fixed on prosthesis. Prosthesis retention is independent of the height of coronal part and the evidence of its survey line. Gentle preparation of abutment teeth allows grinding off hard tooth issues minimally. The combination of fixing elements of a single clasp provides sufficient fixation to achieve high masticatory efficiency and prosthesis spatial stabilization but at the same time only partially limits its lability in mastication. The clasp can be used in free-end saddle restoration both in maxilla and mandible, and especially in patients with periodontal diseases complicated by partial tooth loss.

  5. A compact lightweight aerosol spectrometer probe (CLASP)

    NARCIS (Netherlands)

    Hill, M.K.; Brooks, B.J.; Norris, S.J.; Smith, M.H.; Brooks, I.M.; Leeuw, G. de

    2008-01-01

    The Compact Lightweight Aerosol Spectrometer Probe (CLASP) is an optical particle spectrometer capable of measuring size-resolved particle concentrations in 16 user-defined size bins spanning diameters in the range 0.24 < D < 18.5 μm at a rate of 10 Hz. The combination of its compact nature and ligh

  6. Ly-alpha polarimeter design for CLASP rocket experiment

    CERN Document Server

    Watanabe, H; Kubo, M; Ishikawa, R; Bando, T; Kano, R; Tsuneta, S; Kobayashi, K; Ichimoto, K; Trujillo-Bueno, J

    2014-01-01

    A sounding-rocket program called the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is proposed to be launched in the summer of 2014. CLASP will observe the solar chromosphere in Ly-alpha (121.567 nm), aiming to detect the linear polarization signal produced by scattering processes and the Hanle effect for the first time. The polarimeter of CLASP consists of a rotating half-waveplate, a beam splitter, and a polarization analyzer. Magnesium Fluoride (MgF2) is used for these optical components, because MgF2 exhibits birefringent property and high transparency at ultraviolet wavelength.

  7. Synthesis, optical and field emission properties of ZnO microhair-clasps

    International Nuclear Information System (INIS)

    ZnO microhair-clasps were synthesized on silicon substrate by the vapor-phase transport method at the temperature of 900 deg. C under atmospheric pressure. The microstructure and morphology of ZnO microhair-clasps were evaluated by using X-ray diffraction, scanning electron microscopy and transmission electron microscopy. The growth mechanism of the microhair-clasps was investigated. Room temperature photoluminescence spectra of the microhair-clasps showed a weak UV emission band centering at about 388 nm and wide green emissions around 525 nm. Field emission measurements demonstrated that the microhair-clasps with many sharp tips of several nanometers in curvature radius possessed good performance with a turn-on field of ∼1.5 V/μm and a threshold field of ∼4.3 V/μm.

  8. Comparison of Retention of Clasps Made of Different Materials Using Three-Dimensional Finite Element Analysis

    Science.gov (United States)

    Reddy, Jaggari Chandrakanth; Srikakula, Naveen Kumar; Juturu, Rajesh Kumar Reddy; Paidi, Shameen Kumar; Tedlapu, Satyendra Kumar; Mannava, Padmakanth; Khatoon, Rukhaiya

    2016-01-01

    Introduction Retention and esthetics are believed to play a crucial role in deciding the success of removable partial dentures. Aim To compare retention of acetal resin and cobalt–chromium clasps. Materials and Methods A finite element model was designed with an edentulous space between mandibular right second premolar and second molar. Occlusal rests were placed on distal fossa of the second premolar and mesial fossa of second molar. An undercut depth of 0.01inch was created on the mesiobuccal surface of the premolar and distobuccal surface of second molar. Three dimensional finite element model of clasp assembly was designed and assigned with the properties of two different materials namely acetal resin and cobalt–chromium in successive steps. A horizontal bar was constructed between the occlusal rests of the prosthesis. Later, variable amount of dislodging force, in increasing order, was applied at the centre of the horizontal bar and the force at which the clasp arm gets dislodged was noted with respect to each of the material. The obtained values were noted and then subsequently analyzed. Results The amount of force required to dislodge acetal resin and cobalt–chromium clasps was found to be 0.02N and 2N respectively. Conclusion The results obtained suggested that acetal resin clasp exhibited less retentive force than cobalt–chromium clasps. PMID:27437346

  9. Influence of supply of heat to cobalt-chromium frameworks during soldering and subsequent hardening heat treatment of wrought clasps.

    Science.gov (United States)

    Eriksson, T; Sjögren, G; Bergman, M

    1983-01-01

    Retentive clasp arms of wrought gold alloy wire were soldered to frameworks made of three dental cobalt-chromium alloys. The clasps were then subjected to a conventional hardening heat treatment. Microstructure and hardness of the cobalt-chromium alloys were determined before and after these operations. The results reveal that the supply of heat during soldering and hardening heat treatment of the clasp does not influence the microstructure and hardness of the cobalt-chromium alloys. PMID:6134347

  10. Comparison of human and porcine gastric clasp and sling fiber contraction by M2 and M3 muscarinic receptors

    OpenAIRE

    Vegesna, Anil K.; Braverman, Alan S.; Miller, Larry S.; Tallarida, Ronald J.; Tiwana, Mansoor I.; Khayyam, Umar; RUGGIERI, MICHAEL R.

    2010-01-01

    To compare the gastroesophageal junction of the human with the pig, M2 and M3 receptor densities and the potencies of M2 and M3 muscarinic receptor subtype selective antagonists were determined in gastric clasp and sling smooth muscle fibers. Total muscarinic and M2 receptors are higher in pig than human clasp and sling fibers. M3 receptors are higher in human compared with pig sling fibers but lower in human compared with pig clasp fibers. Clasp fibers have fewer M3 receptors than sling fibe...

  11. Multiple domains of human CLASP contribute to microtubule dynamics and organization in vitro and in Xenopus egg extracts.

    Science.gov (United States)

    Patel, Kieren; Nogales, Eva; Heald, Rebecca

    2012-03-01

    Cytoplasmic linker associated proteins (CLASPs) comprise a class of microtubule (MT) plus end-binding proteins (+TIPs) that contribute to the dynamics and organization of MTs during many cellular processes, among them mitosis. Human CLASP proteins contain multiple MT-binding domains, including tumor over-expressed gene (TOG) domains, and a Ser-x-Ile-Pro (SxIP) motif known to target some +TIPs though interaction with end-binding protein 1 (EB1). However, how individual domains contribute to CLASP function is poorly understood. We generated full-length recombinant human CLASP1 and a series of truncation mutants and found that two N-terminal TOG domains make the strongest contribution to MT polymerization and bundling, but also identified a third TOG domain that further contributes to CLASP activity. Plus end tracking by CLASP requires the SxIP motif and interaction with EB1. The C-terminal coiled-coil domain mediates dimerization and association with many other factors, including the kinetochore motor centromere protein E (CENP-E), and the chromokinesin Xkid. Only the full-length protein was able to rescue spindle assembly in Xenopus egg extracts depleted of endogenous CLASP. Deletion of the C-terminal domain caused aberrant MT polymerization and dramatic spindle phenotypes, even with small amounts of added protein, indicating that proper localization of CLASP activity is essential to control MT polymerization during mitosis. PMID:22278908

  12. In-Flight Performance of the Polarization Modulator in the CLASP Rocket Experiment

    Science.gov (United States)

    Ishikawa, Shin-nosuke; Shimizu, Toshifumi; Kano, Ryohei; Bando, Takamasa; Ishikawa, Ryoko; Giono, Gabriel; Beabout, Dyana L.; Beabout, Brent L.; Nakayama, Satoshi; Tajima, Takao

    2016-01-01

    We developed a polarization modulation unit (PMU), a motor system to rotate a waveplate continuously. In polarization measurements, the continuous rotating waveplate is an important element as well as a polarization analyzer to record the incident polarization in a time series of camera exposures. The control logic of PMU was originally developed for the next Japanese solar observation satellite SOLAR-C by the SOLAR-C working group. We applied this PMU for the Chromospheric Lyman-alpha SpectroPolarimeter (CLASP). CLASP is a sounding rocket experiment to observe the linear polarization of the Lyman-alpha emission (121.6 nm vacuum ultraviolet) from the upper chromosphere and transition region of the Sun with a high polarization sensitivity of 0.1 % for the first time and investigate their vector magnetic field by the Hanle effect. The driver circuit was developed to optimize the rotation for the CLASP waveplate (12.5 rotations per minute). Rotation non-uniformity of the waveplate causes error in the polarization degree (i.e. scale error) and crosstalk between Stokes components. We confirmed that PMU has superior rotation uniformity in the ground test and the scale error and crosstalk of Stokes Q and U are less than 0.01 %. After PMU was attached to the CLASP instrument, we performed vibration tests and confirmed all PMU functions performance including rotation uniformity did not change. CLASP was successfully launched on September 3, 2015, and PMU functioned well as designed. PMU achieved a good rotation uniformity, and the high precision polarization measurement of CLASP was successfully achieved.

  13. The Chromospheric Lyman Alpha SpectroPolarimeter (CLASP)

    Science.gov (United States)

    Kobayashi, K.; Tsuneta, S.; Trujillo Bueno, J.; Cirtain, J. W.; Bando, T.; Kano, R.; Hara, H.; Fujimura, D.; Ueda, K.; Ishikawa, R.; Watanabe, H.; Ichimoto, K.; Sakao, T.; de Pontieu, B.; Carlsson, M.; Casini, R.

    2010-12-01

    Magnetic fields in the solar chromosphere play a key role in the energy transfer and dynamics of the solar atmosphere. Yet a direct observation of the chromospheric magnetic field remains one of the greatest challenges in solar physics. While some advances have been made for observing the Zeeman effect in strong chromospheric lines, the effect is small and difficult to detect outside sunspots. The Hanle effect offers a promising alternative; it is sensitive to weaker magnetic fields (e.g., 5-500 G for Ly-Alpha), and while its magnitude saturates at stronger magnetic fields, the linear polarization signals remain sensitive to the magnetic field orientation. The Hanle effect is not only limited to off-limb observations. Because the chromosphere is illuminated by an anisotropic radiation field, the Ly-Alpha line is predicted to show linear polarization for on-disk, near-limb regions, and magnetic field is predicted to cause a measurable depolarization. At disk center, the Ly-Alpha radiation is predicted to be negligible in the absence of magnetic field, and linearly polarized to an order of 0.3% in the presence of an inclined magnetic field. The proposed CLASP sounding rocket instrument is designed to detect 0.3% linear polarization of the Ly-Alpha line at 1.5 arcsecond spatial resolution (0.7’’ pixel size) and 10 pm spectral resolution. The instrument consists of a 30 cm aperture Cassegrain telescope and a dual-beam spectropolarimeter. The telescope employs a ``cold mirror’’ design that uses multilayer coatings to reflect only the target wavelength range into the spectropolarimeter. The polarization analyzer consists of a rotating waveplate and a polarizing beamsplitter that comprises MgF2 plates placed at Brewster’s Angle. Each output beam of the polarizing beamsplitter, representing two orthogonal linear polarizations, is dispersed and focused using a separate spherical varied-line-space grating, and imaged with a separate 512x512 CCD camera. Prototypes

  14. Cloning and Expression Analysis of GhCLASP1 Gene in Gossypium hirsutum L.%棉花微管结合蛋白基因GhCLASP1的克隆与表达分析

    Institute of Scientific and Technical Information of China (English)

    朱守鸿; 薛飞; 赵兰杰; 刘永昌; 李艳军; 熊显鹏; 孙杰

    2015-01-01

    CLASP蛋白(CLASPs)是一种能够特异地与微管结合,参与调节微管结构与功能的微管结合蛋白(MAPs),在植物细胞形成、细胞伸长等方面起着关键作用.该研究利用电子克隆结合RT-PCR技术从陆地棉(Gossypium hirsutumL.)中克隆获得1个CLASP基因,命名为GhCLASP1(NCBI登录号为KP742966).序列分析显示,GhCLASP1属于CLASP基因家族,开放阅读框长度为4 188 bp,编码含1 395个氨基酸残基的蛋白;Gh-CLASP1蛋白含有1个HEAT重复结构域和2个CLASP-N端结构域.进化分析表明,GhCLASP1与可可树(Theobroma cacao)CLASP蛋白的亲缘关系最近.qRT-PCR分析表明,GhCLASP1在棉花的根、茎、叶、花及纤维发育的不同时期均有表达,且GhCLASP1基因表达量最大值出现在纤维发育次生壁加厚期(开花后27 d),推测GhCLASP1基因可能对棉花纤维次生壁的形成起着重要的作用.利用本氏烟草(Nicotiana benthamiana)叶片瞬时表达系统对GhCLASP1基因编码的蛋白进行亚细胞定位结果显示,GhCLASP1蛋白定位在细胞膜上.上述结果为进一步研究CLASP基因在棉花中的功能奠定了基础.

  15. Podosome-regulating kinesin KIF1C translocates to the cell periphery in a CLASP-dependent manner

    Science.gov (United States)

    Efimova, Nadia; Grimaldi, Ashley; Bachmann, Alice; Frye, Keyada; Zhu, Xiaodong; Feoktistov, Alexander; Straube, Anne; Kaverina, Irina

    2014-01-01

    ABSTRACT The kinesin KIF1C is known to regulate podosomes, actin-rich adhesion structures that remodel the extracellular matrix during physiological processes. Here, we show that KIF1C is a player in the podosome-inducing signaling cascade. Upon induction of podosome formation by protein kinase C (PKC), KIF1C translocation to the cell periphery intensifies and KIF1C accumulates both in the proximity of peripheral microtubules that show enrichment for the plus-tip-associated proteins CLASPs and around podosomes. Importantly, without CLASPs, both KIF1C trafficking and podosome formation are suppressed. Moreover, chimeric mitochondrially targeted CLASP2 recruits KIF1C, suggesting a transient CLASP–KIF1C association. We propose that CLASPs create preferred microtubule tracks for KIF1C to promote podosome induction downstream of PKC. PMID:25344256

  16. Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of removable partial denture

    Directory of Open Access Journals (Sweden)

    Šćepanović Miodrag

    2013-01-01

    Full Text Available Bacground/Aim. Retentive force of removable partial denture (RPD directly depends on elastic force of stretched retentive clasp arms (RCAs. During deflection RCA must have even stress distribution. Safety factor is the concept which can be applied in estimating durability and functionality of RCAs. This study was based on analyzing properties of clasps designed by conventional clasp wax profiles and defining the optimal shapes of RCAs for stress distribution and safety factor aspects. Methods. Computer-aided-design (CAD models of RCAs with simulated properties of materials used for fabrication of RPD cobalt-chromium-molybdenum (CoCrMo alloy, commercially pure titanium (CPTi and polyacetale were analyzed. Results. The research showed that geometrics of Rapidflex profiles from the BIOS concept are defined for designing and modeling RCAs from CoCrMo alloys. I-Bar and Bonihard clasps made from CPTi might have the same design as Co- CrMo clasp only by safety factor aspect, but it is obvious that CPTi are much more flexible, so their shape must be more massive. Polyacetale clasps should not be fabricated by BIOS concept for CoCrMo alloy. A proof for that is the low value of safety factor. Conclusion. The BIOS concept should be used only for RCAs made of CoCrMo alloy and different wax profiles should be used for fabricating clasps of other investigated materials. The contribution of this study may be the improvement of present systems for defining the clasps shapes made from CoCrMo alloys. The more significant application is possibility of creating new concepts in defining shapes of RCA made from CPTi and polyacetale.

  17. Planning Coverage Campaigns for Mission Design and Analysis: Clasp for the Proposed DESDynI Mission

    Science.gov (United States)

    Knight, Russell; McLaren, David; Hu, Steven

    2012-01-01

    Mission design and analysis present challenges in that almost all variables are in constant flux, yet the goal is to achieve an acceptable level of performance against a concept of operations, which might also be in flux. To increase responsiveness, our approach is to use automated planning tools that allow for the continual modification of spacecraft, ground system, staffing, and concept of operations while returning metrics that are important to mission evaluation, such as area covered, peak memory usage, and peak data throughput. We have applied this approach to DESDynI (Deformation, Ecosystem Structure, and Dynamics of Ice) mission design concept using the CLASP (Compressed Large-scale Activity Scheduler/Planner) planning system [7], but since this adaptation many techniques have changed under the hood for CLASP and the DESDynI mission concept has undergone drastic changes, including that it has been renamed the Earth Radar Mission. Over the past two years, we have run more than fifty simulations with the CLASP-DESDynI adaptation, simulating different mission scenarios with changing parameters including targets, swaths, instrument modes, and data and downlink rates. We describe the evolution of simulations through the DESDynI MCR (Mission Concept Review) and afterwards.

  18. Fatigue strength of Co-Cr-Mo alloy clasps prepared by selective laser melting.

    Science.gov (United States)

    Kajima, Yuka; Takaichi, Atsushi; Nakamoto, Takayuki; Kimura, Takahiro; Yogo, Yoshiaki; Ashida, Maki; Doi, Hisashi; Nomura, Naoyuki; Takahashi, Hidekazu; Hanawa, Takao; Wakabayashi, Noriyuki

    2016-06-01

    We aimed to investigate the fatigue strength of Co-Cr-Mo clasps for removable partial dentures prepared by selective laser melting (SLM). The Co-Cr-Mo alloy specimens for tensile tests (dumbbell specimens) and fatigue tests (clasp specimens) were prepared by SLM with varying angles between the building and longitudinal directions (i.e., 0° (TL0, FL0), 45° (TL45, FL45), and 90° (TL90, FL90)). The clasp specimens were subjected to cyclic deformations of 0.25mm and 0.50mm for 10(6) cycles. The SLM specimens showed no obvious mechanical anisotropy in tensile tests and exhibited significantly higher yield strength and ultimate tensile strength than the cast specimens under all conditions. In contrast, a high degree of anisotropy in fatigue performance associated with the build orientation was found. For specimens under the 0.50mm deflection, FL90 exhibited significantly longer fatigue life (205,418 cycles) than the cast specimens (112,770 cycles). In contrast, the fatigue lives of FL0 (28,484 cycles) and FL45 (43,465 cycles) were significantly shorter. The surface roughnesses of FL0 and FL45 were considerably higher than those of the cast specimens, whereas there were no significant differences between FL90 and the cast specimens. Electron backscatter diffraction (EBSD) analysis indicated the grains of FL0 showed preferential close to orientation of the γ phase along the normal direction to the fracture surface. In contrast, the FL45 and FL90 grains showed no significant preferential orientation. Fatigue strength may therefore be affected by a number of factors, including surface roughness and crystal orientation. The SLM process is a promising candidate for preparing tough removable partial denture frameworks, as long as the appropriate build direction is adopted. PMID:26974490

  19. Planning Coverage Campaigns for Mission Design and Analysis: CLASP for DESDynl

    Science.gov (United States)

    Knight, Russell L.; McLaren, David A.; Hu, Steven

    2013-01-01

    Mission design and analysis presents challenges in that almost all variables are in constant flux, yet the goal is to achieve an acceptable level of performance against a concept of operations, which might also be in flux. To increase responsiveness, automated planning tools are used that allow for the continual modification of spacecraft, ground system, staffing, and concept of operations, while returning metrics that are important to mission evaluation, such as area covered, peak memory usage, and peak data throughput. This approach was applied to the DESDynl mission design using the CLASP planning system, but since this adaptation, many techniques have changed under the hood for CLASP, and the DESDynl mission concept has undergone drastic changes. The software produces mission evaluation products, such as memory highwater marks, coverage percentages, given a mission design in the form of coverage targets, concept of operations, spacecraft parameters, and orbital parameters. It tries to overcome the lack of fidelity and timeliness of mission requirements coverage analysis during mission design. Previous techniques primarily use Excel in ad hoc fashion to approximate key factors in mission performance, often falling victim to overgeneralizations necessary in such an adaptation. The new program allows designers to faithfully represent their mission designs quickly, and get more accurate results just as quickly.

  20. Nickel release from inexpensive jewelry and hair clasps purchased in an EU country - Are consumers sufficiently protected from nickel exposure?

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Menné, Torkil; Johansen, Jeanne Duus

    2009-01-01

    population was protected from high cutaneous nickel concentrations. Despite a decrease, the prevalence of nickel allergy remains high as nearly 10% of young women are nickel allergic. OBJECTIVE: This study aimed to perform dimethylglyoxime (DMG) testing of inexpensive jewelry and hair clasps purchased from...... random stores in Copenhagen, Denmark to detect the proportion of items that may result in nickel allergy. METHODS: Inexpensive jewelry and hair clasps were purchased from 36 stores and street vendors in Copenhagen and were later tested for nickel release using the DMG test. RESULTS: The study showed......BACKGROUND: Nickel allergic subjects are at risk factor of acquiring hand eczema. In 1990 and 1994, respectively, Denmark and member states in the EU regulated nickel release from selected consumer products. The intention was that the nickel epidemic could be controlled and prevented if the general...

  1. Study on deformation of acetal resin clasp in vitro%缩醛树脂卡环形变的体外实验研究

    Institute of Scientific and Technical Information of China (English)

    廖岚; 王军; 欧阳少波; 朱洪水

    2011-01-01

    Objective To observe the tendency of deformation of acetal resin clasps during the repeated cycles of placement and removal. Methods The Co-Cr clasps and the acetal resin-Co-Cr clasps used in clinic were tested by instron electronic universal testing machine and electronic digital display. To measure the change of distance between the retention clasps and resistance clasps, and the change of thickness of the acetal resin-Co-Cr clasps on premolar of different material (heat curing resin teeth, extracted teeth, cobalt-chromium alloy teeth) before and after 2 880 dislocation cycles. Results After 2 880 dislocation cycles, there was significant increase in the distance between the tips of Co-Cr clasps (P 0. 05 ). On the tooth of different material, the thickness of acetal resin clasps all showed tendency of attenuation, the thickness of clasps on heat curing resin teeth was significantly higher than the other two types (P<0.05). Conclusions The deformation of acetal resin clasp was lower than casting clasp. There were significant differences among the deformation of acetal resin clasp on various material teeth.%目的 观察缩醛树脂(POM)卡环在反复脱位循环过程中形变的变化趋势.方法 使用 Instron电子万能材料试验机和电子数显卡测试钻铬合金卡环和临床常用 POM—钻铬合金联合三臂卡环在不同材质(热凝塑料牙、离体牙、钻铬合金牙)前磨牙上2 880次脱位循环前后,卡环固位臂卡环尖和抗力臂卡环尖之 间的距离变化值,以及POM—钻铬合金联合三臂卡环固位臂厚度的变化值.结果 2 880次循环周期后,钻铬合金卡环的固位臂卡环尖和抗力臂卡环尖之间的距离增加(p<0.O1),而POM卡环的固位臂卡环尖和抗力臂卡环尖之间的距离无明显变化(p>0.05);在不同材质基牙上,POM卡环臂厚度均呈衰减趋势,塑料牙组卡环臂的厚度测定值分别高于离体牙组和钻铬合金牙组(P均<0.05).结论 POM卡环形变

  2. Protein 4.1R binds to CLASP2 and regulates dynamics,organization and attachment of microtubules to the cell cortex

    NARCIS (Netherlands)

    A. Ruiz-Saenz (Ana); J. van Haren (Jeffrey); C.L. Sayas (C. Laura); L. Rangel (Laura); J.A.A. Demmers (Jeroen); J. Millán (Jaime); M.A. Alonso (Miguel); N.J. Galjart (Niels); J.M. Correas

    2013-01-01

    textabstractThe microtubule (MT) cytoskeleton is essential for many cellular processes, including cell polarity and migration. Cortical platforms, formed by a subset of MT plus-end-tracking proteins, such as CLASP2, and non-MT binding proteins such as LL5b, attach distal ends of MTs to the cell cort

  3. Resilient Attachments as an Alternative to Conventional Cast Clasp Removable Partial Denture: 3-Year Follow-up.

    Science.gov (United States)

    Schuh, Cristian; Adiel Skupien, Jovito; Mesko, Mauro Elias; Valentini, Fernanda; Pereira-Cenci, Tatiana; Boscato, Noéli

    2014-12-01

    The present clinical report describes the prosthodontic management for a patient with uncontrolled bleeding and diabetes mellitus treated with a maxillary complete denture and a mandibular partial fixed dental prosthesis designed to interface with a removable cast framework partial denture retained by 2 ERA attachments. This approach was undertaken to improve both retention and stability of the distal extension Kennedy Class I removable partial denture. The rehabilitation provided better anterior esthetics than if treated with a conventional clasp retained removable partial denture, by employing a simple, practical design and offering a significant biomechanical advantages, restoring both oral health and function. Thus, this treatment modality, involving an ERA system and transfixation in fixed crowns, is an effective treatment and can be indicated as a clinical alternative for edentulous and partially edentulous patients with systemic disorders or for patients in economic situations that might preclude implant-based rehabilitation. PMID:26199530

  4. Surgical treatment of congenital clasped thumb%先天性钩状拇指的手术治疗

    Institute of Scientific and Technical Information of China (English)

    刘涛; 张文同; 朱凌冬; 孙立泉; 于旸; 王广宇; 李开升

    2010-01-01

    Objective To present the surgical management of congenital clasped thumb.Methods The clinical data of 17 patients with congenital clasped thumb(CCT)were analyzed retrospectively.Thirty four affected hands of 17 patients with an average of 7 years and 9 months were recruited in this study.According to the Weckesser's classification,of the 17 cases,9 were graded as type Ⅰ,5 were type Ⅱ.and three were type Ⅲ.The 9 patients with type Ⅰ CCT underwent corrective surgery to transfer the extensor indicis proprius or the extensor carpi radialis longus,and transplant the palmaris longus to reconstruct the function of the thumb extensor digitorum.Of the other 8 patients with type Ⅱ and Ⅲ CCT,the affected hands were treated by releasing the contracture of finger web,the articular capsule of metacarpophalangeal joint,posterior interosseous fascia and the metacarpal bone insertion of caput transversum musculi adductoris hallucis:besides these,the same surgical procedure used on type Ⅰ patients was also performed to correct the deformities.Resalts All patients have been followed up for 7 months to 15 years.Among them,the healing and function of the fingers were excellent in 11 patients (64.7%).good in 3(64.7%),moderate in 2(64.7%)middle,and poor in 1(5.9%).Conclusions The surgical management for congenital clasped thumb should be planned individually to achieve better outcomes.%目的 探讨先天性钩状拇指不同类型的手术治疗方法.方法 回顾分析山东大学齐鲁儿童医院小儿外科手术治疗的17例先天性钩状拇指的临床资料.17例均为双侧,共34手,年龄3~9岁(平均7岁9月);参照Weckesser分型.本组同一患儿双手分型相同,其中Ⅰ型9例(52.9%),Ⅱ型5例(29.4%),Ⅲ型3例(17.6%);Ⅰ型采用示指固有伸肌转移或桡侧腕长伸肌和掌长肌腱移植重建拇指伸肌功能;Ⅱ、Ⅲ型通过松解指蹼挛缩、掌指关节关节囊、背侧骨问筋膜及拇收肌横头第三掌骨止点.并采用示

  5. Ontogeny of a social custom in wild chimpanzees: age changes in grooming hand-clasp at Mahale.

    Science.gov (United States)

    Nakamura, Michio; Nishida, Toshisada

    2013-02-01

    Among cultural behaviors of chimpanzees, the developmental processes of complex skills involved in tool use are relatively well known. However, few studies have examined the ontogeny of social customs that do not require complex skills. Thus, in this study, we describe the developmental process of the grooming hand-clasp (GHC), one of the well-known social customs of chimpanzees at Mahale. We have collected 383 cases of GHC where at least one of the participants was 15 years old or younger during 1994-2007. First performances of GHC with the mother were observed at around 4-6 years old; the earliest observed age was 4 years and 4 months old. The first performances of GHC with nonrelated females were at around age 9 years, and those with adult males at around 11 years. However, some orphans engaged in GHC earlier than nonorphans. By gradually expanding GHC partners from the mother to other females and then to males, chimpanzees increased the number of GHC partners with age. Young males were observed to perform GHC with larger numbers of partners than were young females. GHC by young chimpanzees was shorter in duration than that among adults. Overall, the ontogeny of GHC showed several dissimilarities with that of tool use and was more an extension of the development of typical grooming behavior. For example, infants did not try to perform GHC initially; instead, mothers were more active in the earliest stages. These results suggest that not all socially learned cultural behaviors are acquired in the way of learning tool use. There may be various ways of learning behavioral patterns that are performed continuously in a group and that consequently comprise culture in chimpanzees. PMID:23184762

  6. 便携式机床卡环有限元分析与结构优化%Finite element analysis and structure optimization of the clasp of portable machine

    Institute of Scientific and Technical Information of China (English)

    罗生梅; 杨德宇

    2011-01-01

    According to the load conditions and structure of the clasp, the finite element model ( FEM) of which is established by means of finite element method. Then, based on the static and modal analysis of the clasp, the contours of von stress and displacement, the first four natural frequencies, mode shapes and modal displacement contours of the clasp are presented. In addition, the global sensitivity analysis of the important design parameters is analyzed. Finally, the overall quality minimum of the clasp is taken as an objective, the optimal values of important design parameters are determined and the structure of clasp suitable for engineering application requirements is obtained.%针对卡环承载状况和结构特点,运用有限元优化设计方法,建立了卡环的有限元分析模型,进行了静态和模态分析,分别给出了卡环等效应力和位移云图,卡环前4阶固有频率、相应振型描述和模态位移云图,并对其重要设计参数进行了全局灵敏度分析.在此基础上,以卡环整体质量最小为目标,确定了重要设计参数的最优值,最终得到符合工程应用要求的卡环结构形状.

  7. Inhibition of αIIbβ3 Ligand Binding by an αIIb Peptide that Clasps the Hybrid Domain to the βI Domain of β3.

    Directory of Open Access Journals (Sweden)

    Wen Hwa Lee

    Full Text Available Agonist-stimulated platelet activation triggers conformational changes of integrin αIIbβ3, allowing fibrinogen binding and platelet aggregation. We have previously shown that an octapeptide, p1YMESRADR8, corresponding to amino acids 313-320 of the β-ribbon extending from the β-propeller domain of αIIb, acts as a potent inhibitor of platelet aggregation. Here we have performed in silico modelling analysis of the interaction of this peptide with αIIbβ3 in its bent and closed (not swing-out conformation and show that the peptide is able to act as a substitute for the β-ribbon by forming a clasp restraining the β3 hybrid and βI domains in a closed conformation. The involvement of species-specific residues of the β3 hybrid domain (E356 and K384 and the β1 domain (E297 as well as an intrapeptide bond (pE315-pR317 were confirmed as important for this interaction by mutagenesis studies of αIIbβ3 expressed in CHO cells and native or substituted peptide inhibitory studies on platelet functions. Furthermore, NMR data corroborate the above results. Our findings provide insight into the important functional role of the αIIb β-ribbon in preventing integrin αIIbβ3 head piece opening, and highlight a potential new therapeutic approach to prevent integrin ligand binding.

  8. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  9. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  10. Concentration device

    DEFF Research Database (Denmark)

    2013-01-01

    A concentration device (2) for filter filtration concentration of particles (4) from a volume of a fluid (6). The concentration device (2) comprises a filter (8) configured to filter particles (4) of a predefined size in the volume of the fluid (6). The concentration device (2) comprises...

  11. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2016-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  12. Thermonuclear device

    International Nuclear Information System (INIS)

    Purpose: To provide a thermonuclear device which causes the thermal expansion of a vacuum vessel to freely escape without refraining and is provided with a vacuum vessel having an excellently large rigidity against an electromagnetic force transiently acting whils retaining a predetermined position. Constitution: The device for supporting the vacuum vessel comprises piston cylinder means in which a pressurized fluid is sealed in cylinder chambers at both sides of a piston and with which these cylinder chambers are liquidly communicated through throttling means, and means for fixing any of the piston and the cylinder of said piston cylinder means to a bed-plate retaining the support device and another to the vacuum vessel. The vacuum vessel is retained through a connecting rod or the like connected to the cylinder of the support device. (Aizawa, K.)

  13. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  14. Superconducting device

    International Nuclear Information System (INIS)

    The present invention provides a superconducting device to be used in a thermonuclear device and capable of unifying a current distribution in a parallel superconducting main line without consumption of liquid helium caused by Joule loss. That is, the device has a paired coils comprising a coil comprising one of plurality of superconducting wires and another coil comprising the other of plurality of superconducting wires and having a reverse winding or negative mutual inductance relative to the coil. A circuit comprising a portion of a main line is disposed to the one coil of the paired coils, and a circuit comprising the remainder of the main line is connected to the other coil each in series. The circuit has a parallel constitution. Such a constitution can provide an effect of unifying the current distribution in the main line without consumption of liquid helium due to Joule loss. (I.S.)

  15. Stratification devices

    DEFF Research Database (Denmark)

    Andersen, Elsa; Furbo, Simon

    2008-01-01

    results in longer operation periods and improved utilization of the solar collector. Thermal stratification can be achieved, for example by using inlet stratification devices at all inlets to the storage tank. This paper presents how thermal stratification is established and utilized by means of inlet...

  16. Thermonuclear device

    International Nuclear Information System (INIS)

    Purpose: To absorb fabrication errors in radial toroidal coils and a spacer and completely fill the gap between them by the provision of an expansion device between the coils and the supporting spacer by injecting fillers of a predetermined composition. Constitution: An expansion device comprising an expansion plate, packings inserted into grooves formed in the outer circumference of the expansion plate and a recessed pressure receiving plate is inserted between the wall surface of radial toroidal coils and a spacer for maintaining the gap between the toroidal coils. Then, filler comprising polyester resin and glass beads incorporated therein is injected from an injection aperture of the recessed pressure receiving plate having an exhaust aperture at the upper part. The filler is solidified and enables the fabrication error in the coils and the spacer to be absorbed. Since the gap between the coils and the spacer is completely filled, the tumbling force of the coils can surely be transmitted by way of the spacer to upper and lower racks. (Moriyama, K.)

  17. Scalable devices

    KAUST Repository

    Krüger, Jens J.

    2014-01-01

    In computer science in general and in particular the field of high performance computing and supercomputing the term scalable plays an important role. It indicates that a piece of hardware, a concept, an algorithm, or an entire system scales with the size of the problem, i.e., it can not only be used in a very specific setting but it\\'s applicable for a wide range of problems. From small scenarios to possibly very large settings. In this spirit, there exist a number of fixed areas of research on scalability. There are works on scalable algorithms, scalable architectures but what are scalable devices? In the context of this chapter, we are interested in a whole range of display devices, ranging from small scale hardware such as tablet computers, pads, smart-phones etc. up to large tiled display walls. What interests us mostly is not so much the hardware setup but mostly the visualization algorithms behind these display systems that scale from your average smart phone up to the largest gigapixel display walls.

  18. Practical microwave electron devices

    CERN Document Server

    Meurant, Gerard

    2013-01-01

    Practical Microwave Electron Devices provides an understanding of microwave electron devices and their applications. All areas of microwave electron devices are covered. These include microwave solid-state devices, including popular microwave transistors and both passive and active diodes; quantum electron devices; thermionic devices (including relativistic thermionic devices); and ferrimagnetic electron devices. The design of each of these devices is discussed as well as their applications, including oscillation, amplification, switching, modulation, demodulation, and parametric interactions.

  19. PLASMA DEVICE

    Science.gov (United States)

    Baker, W.R.

    1961-08-22

    A device is described for establishing and maintaining a high-energy, rotational plasma for use as a fast discharge capacitor. A disc-shaped, current- conducting plasma is formed in an axinl magnetic field and a crossed electric field, thereby creating rotational kinetic enengy in the plasma. Such energy stored in the rotation of the plasma disc is substantial and is convertible tc electrical energy by generator action in an output line electrically coupled to the plasma volume. Means are then provided for discharging the electrical energy into an external circuit coupled to the output line to produce a very large pulse having an extremely rapid rise time in the waveform thereof. (AE C)

  20. Laser device

    Science.gov (United States)

    Scott, Jill R.; Tremblay, Paul L.

    2007-07-10

    A laser device includes a target position, an optical component separated a distance J from the target position, and a laser energy source separated a distance H from the optical component, distance H being greater than distance J. A laser source manipulation mechanism exhibits a mechanical resolution of positioning the laser source. The mechanical resolution is less than a spatial resolution of laser energy at the target position as directed through the optical component. A vertical and a lateral index that intersect at an origin can be defined for the optical component. The manipulation mechanism can auto align laser aim through the origin during laser source motion. The laser source manipulation mechanism can include a mechanical index. The mechanical index can include a pivot point for laser source lateral motion and a reference point for laser source vertical motion. The target position can be located within an adverse environment including at least one of a high magnetic field, a vacuum system, a high pressure system, and a hazardous zone. The laser source and an electro-mechanical part of the manipulation mechanism can be located outside the adverse environment. The manipulation mechanism can include a Peaucellier linkage.

  1. Laser device

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Jill R.; Tremblay, Paul L.

    2004-11-23

    A laser device includes a target position, an optical component separated a distance J from the target position, and a laser energy source separated a distance H from the optical component, distance H being greater than distance J. A laser source manipulation mechanism exhibits a mechanical resolution of positioning the laser source. The mechanical resolution is less than a spatial resolution of laser energy at the target position as directed through the optical component. A vertical and a lateral index that intersect at an origin can be defined for the optical component. The manipulation mechanism can auto align laser aim through the origin during laser source motion. The laser source manipulation mechanism can include a mechanical index. The mechanical index can include a pivot point for laser source lateral motion and a reference point for laser source vertical motion. The target position can be located within an adverse environment including at least one of a high magnetic field, a vacuum system, a high pressure system, and a hazardous zone. The laser source and an electro-mechanical part of the manipulation mechanism can be located outside the adverse environment. The manipulation mechanism can include a Peaucellier linkage.

  2. Medical Device Safety

    Science.gov (United States)

    A medical device is any product used to diagnose, cure, or treat a condition, or to prevent disease. They range ... may need one in a hospital. To use medical devices safely Know how your device works. Keep instructions ...

  3. Infrared criminalistic devices

    Science.gov (United States)

    Gibin, Igor S.; Savkov, E. V.; Popov, Pavel G.

    1996-12-01

    We are presenting the devices of near-IR spectral range in this report. The devices may be used in criminalistics, in bank business, in restoration works, etc. the action principle of these devices is describing briefly.

  4. Intrauterine devices (IUD)

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007635.htm Intrauterine devices (IUD) To use the sharing features on this page, please enable JavaScript. An intrauterine device (IUD) is a small plastic T-shaped device used ...

  5. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  6. Ultraefficient Themoelectric Devices Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Thermoelectric (TE) devices already found a wide range of commercial, military and aerospace applications. However, at present commercially available TE devices...

  7. Hip supporting device

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention relates to a device for limiting movements in one or more anatomical joints, such as a device for limiting movement in the human hip joint after hip replacement surgery. This is provided by a device for limiting movement in the human hip joint, said device comprising: at least...

  8. Implantable CMOS Biomedical Devices

    Directory of Open Access Journals (Sweden)

    Toshihiko Noda

    2009-11-01

    Full Text Available The results of recent research on our implantable CMOS biomedical devices are reviewed. Topics include retinal prosthesis devices and deep-brain implantation devices for small animals. Fundamental device structures and characteristics as well as in vivo experiments are presented.

  9. Rhetorical Devices in English Advertisements

    Institute of Scientific and Technical Information of China (English)

    陈芃

    2011-01-01

    In order to achieve persuasive and convincing effects,rhetorical devices are frequently applied in English advertisements.The paper classifies rhetorical devices into four basic categories: phonetic devices,lexical devices,syntactic devices and figures of

  10. Alerts and Notices (Devices)

    Science.gov (United States)

    ... powered, Hand-held Lasers Used for Pointing or Entertainment 12/16/10 Medical Device Safety Archive The ... About FDA Contact FDA Browse by Product Area Product Areas back Food Drugs Medical Devices Radiation-Emitting ...

  11. Superlens as matching device

    OpenAIRE

    Veselago, V. G.

    2005-01-01

    The question is considered about possibility of overcoming diffraction limit at device, named superlens. This device is a flat slab, executed from material with index of refraction n,equal n=-1. It is shown, what this device really can focus the radiation to the spot, smaller than wavelength, but herewith superlens works not as optical instrument, based on the laws of geometric optics, but as certain matching device, for which does not exist diffraction limit. This is possible if thickness of...

  12. Development of Medical Devices

    OpenAIRE

    Limaye, Dnyanesh

    2016-01-01

    The medical devices sector helps save lives by providing innovative health care solutions regarding diagnosis, prevention, monitoring, treatment, and alleviation. Medical devices are classified into 1 of 3 categories in the order of increasing risk: Class I, Class II, and Class III.1 Medical devices are distinguished from drugs for regulatory purposes based on mechanism of action. Unlike drugs, medical devices operate via physical or mechanical means and are not dependent on metabolism to acc...

  13. Heterostructures and quantum devices

    CERN Document Server

    Einspruch, Norman G

    1994-01-01

    Heterostructure and quantum-mechanical devices promise significant improvement in the performance of electronic and optoelectronic integrated circuits (ICs). Though these devices are the subject of a vigorous research effort, the current literature is often either highly technical or narrowly focused. This book presents heterostructure and quantum devices to the nonspecialist, especially electrical engineers working with high-performance semiconductor devices. It focuses on a broad base of technical applications using semiconductor physics theory to develop the next generation of electrical en

  14. Photovoltaic device and method

    Science.gov (United States)

    Cleereman, Robert J; Lesniak, Michael J; Keenihan, James R; Langmaid, Joe A; Gaston, Ryan; Eurich, Gerald K; Boven, Michelle L

    2015-01-27

    The present invention is premised upon an improved photovoltaic device ("PVD") and method of use, more particularly to an improved photovoltaic device with an integral locator and electrical terminal mechanism for transferring current to or from the improved photovoltaic device and the use as a system.

  15. Radiation emitting devices act

    International Nuclear Information System (INIS)

    This Act, entitled the Radiation Emitting Devices Act, is concerned with the sale and importation of radiation emitting devices. Laws relating to the sale, lease or import, labelling, advertising, packaging, safety standards and inspection of these devices are listed as well as penalties for any person who is convicted of breaking these laws

  16. Inspection device in liquid

    International Nuclear Information System (INIS)

    The present invention provides an inspection device in PWR reactor core in which inspection operations are made efficient by stabilizing a posture of the device in front-to-back, vertical and left-to-right directions by a simple structure. When the device conducts inspection while running in liquid, the front and the back directions of the device main body are inspected using a visual device while changing the posture by operating a front-to-back direction propulsion device and a right-to-left direction propulsion device, and a vertical direction propulsion device against to rolling, pitching and yawing of the device main body. In this case, a spherical magnet moves freely in the gravitational direction in a vibration-damping fluid in a non-magnetic spherical shell following the change of the posture of the device main body, in which the vibrations due to the movement of the spherical magnet is settled by the vibration-damping fluid thereby stabilizing the posture of the device main body. At a typical inspection posture, the settling effect is enhanced by the attraction force between the spherical magnets in the spherical shell and each of magnetic force-attracted magnetic members disposed to the outer circumference of the shell, and the posture of the device main body can be confirmed in front-to-back, right-to-left and vertical directions by each of the posture confirming magnetic sensors. (N.H.)

  17. 76 FR 8637 - Medical Devices; Medical Device Data Systems

    Science.gov (United States)

    2011-02-15

    ... Devices; Medical Device Data Systems AGENCY: Food and Drug Administration, HHS. ACTION: Final rule... device are not medical devices. (Response) FDA agrees that the term ``medical device data'' could be... medical devices. (Response) An MDDS is intended to be a communication conduit for medical device data.......

  18. Thermography of electronic devices

    Directory of Open Access Journals (Sweden)

    Panfilova S. P.

    2007-12-01

    Full Text Available The possibility of application of thermography to diagnose the electronic devices is analyzed in the article. Typical faults of electronic devices which can be found by means of thermography are given. Advantages of noncontact thermal inspection in comparison with the contact one are described. Some features of thermography of electronic devices are considered. Thermography apparatus is viewed and some pieces of advice about choosing it for electronic devices diagnosis are given. An example of the thermographic method for checking the electronic devices is provided. The main features of software used in thermography and its significance are described.

  19. Optical plasma microelectronic devices

    CERN Document Server

    Forati, Ebrahim; Dill, Thyler; Sievenpiper, Dan

    2015-01-01

    The semiconductor channel in conventional microelectronic devices was successfully replaced with an optically triggered gas plasma channel. The combination of DC and laser-induced gas ionizations controls the conductivity of the channel, enabling us to realize different electronic devices such as transistors, switches, modulators, etc. A special micro-scale metasurface was used to enhance the laser-gas interaction, as well as combining it with DC ionization properly. Optical plasma devices benefit form the advantages of plasma/vacuum electronic devices while preserving most of the integrablity of semiconductor based devices.

  20. Radiation emitting devices regulations

    International Nuclear Information System (INIS)

    The Radiation Emitting Devices Regulations are the regulations referred to in the Radiation Emitting Devices Act and relate to the operation of devices. They include standards of design and construction, standards of functioning, warning symbol specifications in addition to information relating to the seizure and detention of machines failing to comply with the regulations. The radiation emitting devices consist of the following: television receivers, extra-oral dental x-ray equipment, microwave ovens, baggage inspection x-ray devices, demonstration--type gas discharge devices, photofluorographic x-ray equipment, laser scanners, demonstration lasers, low energy electron microscopes, high intensity mercury vapour discharge lamps, sunlamps, diagnostic x-ray equipment, ultrasound therapy devices, x-ray diffraction equipment, cabinet x-ray equipment and therapeutic x-ray equipment

  1. Smart portable rehabilitation devices

    Directory of Open Access Journals (Sweden)

    Leahey Matt

    2005-07-01

    Full Text Available Abstract Background The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s. Methods In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Results Laboratory tests of the devices

  2. FLUIDICS DEVICE FOR ASSAY

    DEFF Research Database (Denmark)

    2007-01-01

    The present invention relates to a device for use in performing assays on standard laboratory solid supports whereon chemical entities are attached. The invention furthermore relates to the use of such a device and a kit comprising such a device. The device according to the present invention is...... adapted to receive one or more replaceable solid support(s) (40) onto which chemical entities (41) are attached, said device comprising a base (1, 60, 80, 300, 400, 10, 70, 140, 20, 90, 120, 150, 30, 100), one or more inlet(s) (5), one or more outlet(s) (6). The base and the solid support (40) defines......, when operatively connected, one or more chambers (21) comprising the chemical entities (41), the inlet(s) (5) and outlet(s) (6) and chambers (21) being in fluid connection. The device further comprise means for providing differing chemical conditions in each chamber (21)....

  3. Mechanical CPR devices

    OpenAIRE

    Halperin, Henry; Carver, David J.

    2010-01-01

    It is recognized that the quality of cardiopulmonary resuscitation (CPR) is an important predictor of outcome from cardiac arrest. Mechanical chest-compression devices provide an alternative to manual CPR. Physiological and animal data suggest that mechanical chest-compression devices are more effective than manual CPR. Consequently, there has been much interest in the development of new techniques and devices to improve the efficacy of CPR. This review will consider the evidence ...

  4. Optical fibre nanowire devices

    OpenAIRE

    Xu, Fei

    2008-01-01

    The Optical Fibre Nanowire (OFN) is a potential building block in future micro- and nano-photonic device since it offers a number of unique optical and mechanical properties. In this thesis, the background and fundamental features of nanowires are introduced; the theory, design and demonstration of novel nanowire devices are discussed. At first, a short adiabatic taper tip is manufactured, and it is used as optical tweezers for trapping 1?m microspheres. Then, the most important devic...

  5. Improvements in compliant devices

    International Nuclear Information System (INIS)

    A compliant device for insertion between an end of a manipulator arm and a tool, the device comprising a plurality of pairs of helicoil assemblies secured at their opposite ends in respective rigid coupling means attachable to the end of the manipulator arm and the tool, adjacent assemblies of neighbouring pairs being inclined such that the axes of the adjacent assemblies meet at points on a circle with the centre of the circle defining the centre of compliance of the device. (author)

  6. Pyrotechnic device reliability

    OpenAIRE

    Ozkil, Altan

    1991-01-01

    The Naval Weapons Support Center is planning to implement a bonus system to improve the reliability of pyrotechnic devices. The measure of effectiveness that they wish to use to determine how to award bonuses is the reliability of pyrotechnic devices. The data available to estimate this reliability is based on the current sampling inspection plan in which devices are tested in different environments. The models which include both dependence and independence assumptions between the outcomes of...

  7. Sensor sentinel computing device

    Energy Technology Data Exchange (ETDEWEB)

    Damico, Joseph P.

    2016-08-02

    Technologies pertaining to authenticating data output by sensors in an industrial environment are described herein. A sensor sentinel computing device receives time-series data from a sensor by way of a wireline connection. The sensor sentinel computing device generates a validation signal that is a function of the time-series signal. The sensor sentinel computing device then transmits the validation signal to a programmable logic controller in the industrial environment.

  8. Establishment Registration & Device Listing

    Data.gov (United States)

    U.S. Department of Health & Human Services — This searchable database contains establishments (engaged in the manufacture, preparation, propagation, compounding, assembly, or processing of medical devices...

  9. New Medical Device Evaluation.

    Science.gov (United States)

    Ikeda, Koji

    2016-01-01

    In this presentation, as a member of the Harmonization by Doing (HBD) project, I discuss the significance of regulatory science in global medical device development and our experience in the international collaboration process for medical devices. In Japan, most innovative medical therapeutic devices were previously developed and exported by foreign-based companies. Due to this device lag, Japanese had minimal opportunities for receiving treatment with innovative medical devices. To address this issue, the Japanese government has actively accepted foreign clinical trial results and promoted global clinical trials in projects such as HBD. HBD is a project with stakeholders from academia, regulatory authorities, and industry in the US and Japan to promote global clinical trials and reduce device lags. When the project started, medical device clinical trials were not actively conducted in Japan at not just hospitals but also at medical device companies. We started to identify issues under the concept of HBD. After 10 years, we have now become key members in global clinical trials and able to obtain approvals without delay. Recently, HBD has started promoting international convergence. Physicians and regulatory authorities play central roles in compiling guidelines for the clinical evaluation of medical device development, which will be a more active field in the near future. The guidelines compiled will be confirmed with members of academia and regulatory authorities in the United Sates. PMID:27040333

  10. Interconnected semiconductor devices

    Science.gov (United States)

    Grimmer, Derrick P.; Paulson, Kenneth R.; Gilbert, James R.

    1990-10-23

    Semiconductor layer and conductive layer formed on a flexible substrate, divided into individual devices and interconnected with one another in series by interconnection layers and penetrating terminals.

  11. Ion trap device

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Yehia M.; Smith, Richard D.

    2016-01-26

    An ion trap device is disclosed. The device includes a series of electrodes that define an ion flow path. A radio frequency (RF) field is applied to the series of electrodes such that each electrode is phase shifted approximately 180 degrees from an adjacent electrode. A DC voltage is superimposed with the RF field to create a DC gradient to drive ions in the direction of the gradient. A second RF field or DC voltage is applied to selectively trap and release the ions from the device. Further, the device may be gridless and utilized at high pressure.

  12. Virtual Training Devices Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Virtual Training Devices (VTD) Laboratory at the Life Cycle Software Engineering Center, Picatinny Arsenal, provides a software testing and support environment...

  13. Cataphoric Devices in Spoken Discourse

    OpenAIRE

    Gernsbacher, Morton Ann; Jescheniak, Jörg D.

    1995-01-01

    We propose that speakers mark key words with cataphoric devices. Cataphoric devices are counterparts to anaphoric devices: Just as anaphoric devices enable backward reference, cataphoric devices enable forward reference. And just as anaphoric devices mark concepts that have been mentioned before, cataphoric devices mark concepts that are likely to be mentioned again. We investigated two cataphoric devices: spoken stress and the indefinite this. Our experiments demonstrated three ways that con...

  14. Radioactive liquid waste processing device

    International Nuclear Information System (INIS)

    The present invention provides a device for processing radioactive liquid wastes generated in a facility of a nuclear power plant, especially suitable to liquid wastes at relatively high electroconductivity and solid content concentration. Namely, the device comprises a vessel for receiving radioactive liquid wastes, a device for concentrating the radioactive liquid wastes and a device for solidifying the liquid wastes. The concentrated liquid wastes can be charged from the concentration device to the receiving container. The concentration device has a precipitation separation function and comprises a supernatant withdrawing section and a solid content withdrawing section. In addition, the concentration device is connected with the receiving device for transferring the supernatant in the concentration device. Further, the receiving device is connected to the solidification device by way of a solid content transferring line, and the precipitated and separated solid content is transferred to a cement solidification device, plastic solidification device, asphalt solidification device, a glass solidification device etc. (I.S.)

  15. Microfabricated particle focusing device

    Energy Technology Data Exchange (ETDEWEB)

    Ravula, Surendra K.; Arrington, Christian L.; Sigman, Jennifer K.; Branch, Darren W.; Brener, Igal; Clem, Paul G.; James, Conrad D.; Hill, Martyn; Boltryk, Rosemary June

    2013-04-23

    A microfabricated particle focusing device comprises an acoustic portion to preconcentrate particles over large spatial dimensions into particle streams and a dielectrophoretic portion for finer particle focusing into single-file columns. The device can be used for high throughput assays for which it is necessary to isolate and investigate small bundles of particles and single particles.

  16. Unconventional Quantum Computing Devices

    OpenAIRE

    Lloyd, Seth

    2000-01-01

    This paper investigates a variety of unconventional quantum computation devices, including fermionic quantum computers and computers that exploit nonlinear quantum mechanics. It is shown that unconventional quantum computing devices can in principle compute some quantities more rapidly than `conventional' quantum computers.

  17. Vaginal mechanical contraceptive devices.

    OpenAIRE

    Smith, M.; Barwin, B. N.

    1983-01-01

    The alleged adverse effects of oral contraceptives and intrauterine devices have led to increased consumer and physician demand for vaginal contraceptive devices. The efficacy and the advantages and disadvantages of vaginal sponges, cervical caps and diaphragms are discussed and compared in this article.

  18. Device for removing blackheads

    Energy Technology Data Exchange (ETDEWEB)

    Berkovich, Tamara (116 N. Wetherly Dr., Suite 115, Los Angeles, CA)

    1995-03-07

    A device for removing blackheads from pores in the skin having a elongated handle with a spoon shaped portion mounted on one end thereof, the spoon having multiple small holes piercing therethrough. Also covered is method for using the device to remove blackheads.

  19. Compound semiconductor device modelling

    CERN Document Server

    Miles, Robert

    1993-01-01

    Compound semiconductor devices form the foundation of solid-state microwave and optoelectronic technologies used in many modern communication systems. In common with their low frequency counterparts, these devices are often represented using equivalent circuit models, but it is often necessary to resort to physical models in order to gain insight into the detailed operation of compound semiconductor devices. Many of the earliest physical models were indeed developed to understand the 'unusual' phenomena which occur at high frequencies. Such was the case with the Gunn and IMPATI diodes, which led to an increased interest in using numerical simulation methods. Contemporary devices often have feature sizes so small that they no longer operate within the familiar traditional framework, and hot electron or even quantum­ mechanical models are required. The need for accurate and efficient models suitable for computer aided design has increased with the demand for a wider range of integrated devices for operation at...

  20. Positioning devices for patients

    International Nuclear Information System (INIS)

    It has been suggested that it is very important to position patients reproducibly at different stages of radiotherapy treatment planning and treatment, or similar procedures. Devices have been described for positioning a patient's upper and lower thorax. This invention provides reproducible positioning for a female patient's breasts, for example in planning treatment of and treating breast tumours. The patient is placed prone, using for example an upper thorax device. A support device is placed central to and beneath her breasts to partially displace them outwards. The device may be triangular in section with one apex contacting the chest wall at the sternum. Restraining straps may be provided to hold the breasts against the support device. Means may be provided to take a healthy breast from the path of radiation through the tumour. (author)

  1. Metallic spintronic devices

    CERN Document Server

    Wang, Xiaobin

    2014-01-01

    Metallic Spintronic Devices provides a balanced view of the present state of the art of metallic spintronic devices, addressing both mainstream and emerging applications from magnetic tunneling junction sensors and spin torque oscillators to spin torque memory and logic. Featuring contributions from well-known and respected industrial and academic experts, this cutting-edge work not only presents the latest research and developments but also: Describes spintronic applications in current and future magnetic recording devicesDiscusses spin-transfer torque magnetoresistive random-access memory (STT-MRAM) device architectures and modelingExplores prospects of STT-MRAM scaling, such as detailed multilevel cell structure analysisInvestigates spintronic device write and read optimization in light of spintronic memristive effectsConsiders spintronic research directions based on yttrium iron garnet thin films, including spin pumping, magnetic proximity, spin hall, and spin Seebeck effectsProposes unique solutions for ...

  2. Plant monitoring device

    International Nuclear Information System (INIS)

    The device of the present invention gives optimum information to operators with simple procedures in accordance with aspects and the states of operation in a nuclear power plant or a chemical plant. That is, pattern matching, etc. are deduced by a plant status judging device based on on-line data for process amount collected by a process input/output device and previously contained status judging intelligence data. Then, the plant status is judged to determine a priority and the states of the plant are collected and integrated in the order of important information of higher superiority. Further, the on-line data described above are arranged and edited by a display driving information providing device based on the result of the judgment in the plant status judging device. The plant information judged to have a high priority and to be important in the plant status judging device is displayed on a display device. With such procedures, complicated and various monitorings and operations of the process plant can be conducted without requiring skills. (I.S.)

  3. Powering biomedical devices

    CERN Document Server

    Romero, Edwar

    2013-01-01

    From exoskeletons to neural implants, biomedical devices are no less than life-changing. Compact and constant power sources are necessary to keep these devices running efficiently. Edwar Romero's Powering Biomedical Devices reviews the background, current technologies, and possible future developments of these power sources, examining not only the types of biomedical power sources available (macro, mini, MEMS, and nano), but also what they power (such as prostheses, insulin pumps, and muscular and neural stimulators), and how they work (covering batteries, biofluids, kinetic and ther

  4. Electronic devices and circuits

    CERN Document Server

    Pridham, Gordon John

    1972-01-01

    Electronic Devices and Circuits, Volume 3 provides a comprehensive account on electronic devices and circuits and includes introductory network theory and physics. The physics of semiconductor devices is described, along with field effect transistors, small-signal equivalent circuits of bipolar transistors, and integrated circuits. Linear and non-linear circuits as well as logic circuits are also considered. This volume is comprised of 12 chapters and begins with an analysis of the use of Laplace transforms for analysis of filter networks, followed by a discussion on the physical properties of

  5. Compound semiconductor device physics

    CERN Document Server

    Tiwari, Sandip

    2013-01-01

    This book provides one of the most rigorous treatments of compound semiconductor device physics yet published. A complete understanding of modern devices requires a working knowledge of low-dimensional physics, the use of statistical methods, and the use of one-, two-, and three-dimensional analytical and numerical analysis techniques. With its systematic and detailed**discussion of these topics, this book is ideal for both the researcher and the student. Although the emphasis of this text is on compound semiconductor devices, many of the principles discussed will also be useful to those inter

  6. Physics of photonic devices

    CERN Document Server

    Chuang, Shun Lien

    2009-01-01

    The most up-to-date book available on the physics of photonic devices This new edition of Physics of Photonic Devices incorporates significant advancements in the field of photonics that have occurred since publication of the first edition (Physics of Optoelectronic Devices). New topics covered include a brief history of the invention of semiconductor lasers, the Lorentz dipole method and metal plasmas, matrix optics, surface plasma waveguides, optical ring resonators, integrated electroabsorption modulator-lasers, and solar cells. It also introduces exciting new fields of research such as:

  7. Smart devices are different

    DEFF Research Database (Denmark)

    Stisen, Allan; Blunck, Henrik; Bhattacharya, Sourav;

    2015-01-01

    research results. This is due to variations in training and test device hardware and their operating system characteristics among others. In this paper, we systematically investigate sensor-, device- and workload-specific heterogeneities using 36 smartphones and smartwatches, consisting of 13 different....... Moreover, the impairments vary significantly across devices and depends on the type of recognition technique used. We systematically evaluate the effect of mobile sensing heterogeneities on HAR and propose a novel clustering-based mitigation technique suitable for large-scale deployment of HAR, where...

  8. Radiations from display devices

    International Nuclear Information System (INIS)

    45 display devices have been analyzed for X-ray emmission and for electrostatic - and low-frequency magnetic fields. 3 have been further analyzed for UV and visible light emmission. No emmissions above established risk levels have been found. For low-frequency magnetic fields very little is known of risks, so the levels have been compared with other commonly used devices. The measured levels correspond roughly to that which occur in the use of an electrical egg-beater, or a small hand electrical drill. Data are presented for the tested devices.(author)

  9. Nanoelectronic device applications handbook

    CERN Document Server

    Morris, James E

    2013-01-01

    Nanoelectronic Device Applications Handbook gives a comprehensive snapshot of the state of the art in nanodevices for nanoelectronics applications. Combining breadth and depth, the book includes 68 chapters on topics that range from nano-scaled complementary metal-oxide-semiconductor (CMOS) devices through recent developments in nano capacitors and AlGaAs/GaAs devices. The contributors are world-renowned experts from academia and industry from around the globe. The handbook explores current research into potentially disruptive technologies for a post-CMOS world.These include: Nanoscale advance

  10. Output hardcopy devices

    CERN Document Server

    Durbeck, Robert

    1988-01-01

    Output Hardcopy Devices provides a technical summary of computer output hardcopy devices such as plotters, computer output printers, and CRT generated hardcopy. Important related technical areas such as papers, ribbons and inks, color techniques, controllers, and character fonts are also covered. Emphasis is on techniques primarily associated with printing, as well as the plotting capabilities of printing devices that can be effectively used for computer graphics in addition to their various printing functions. Comprised of 19 chapters, this volume begins with an introduction to vector and ras

  11. Chromospheric Lyman-alpha spectro-polarimeter (CLASP)

    Czech Academy of Sciences Publication Activity Database

    Kano, R.; Bando, T.; Narukage, N.; Ishikawa, R.; Tsuneta, S.; Katsukawa, Y.; Kubo, M.; Ishikawa, S.; Hara, H.; Shimizu, T.; Suematsu, Y.; Ichimoto, K.; Sakao, T.; Goto, M.; Kato, Y.; Imada, S.; Kobayashi, K.; Holloway, T.; Winebarger, A.; Cirtain, J.; de Pontieu, B.; Casini, R.; Trujillo Bueno, J.; Štěpán, Jiří; Sainz, R.M.; Belluzzi, L.; Ramos, A.A.; Auchere, F.; Carlsson, M.

    Bellingham : International Society for Optical Engineering, 2012, 84434F/1-84434F/17. ISBN 9780819491442. - (Proceedings of SPIE. 8443). [Space Telescopes and Instrumentation 2012: Ultraviolet to Gamma Ray. Amsterdam (NL), 01.07.2012-06.07.2012] Institutional support: RVO:67985815 Keywords : chromospheric magnetic field Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  12. Microreactor Array Device

    Science.gov (United States)

    Wiktor, Peter; Brunner, Al; Kahn, Peter; Qiu, Ji; Magee, Mitch; Bian, Xiaofang; Karthikeyan, Kailash; Labaer, Joshua

    2015-03-01

    We report a device to fill an array of small chemical reaction chambers (microreactors) with reagent and then seal them using pressurized viscous liquid acting through a flexible membrane. The device enables multiple, independent chemical reactions involving free floating intermediate molecules without interference from neighboring reactions or external environments. The device is validated by protein expressed in situ directly from DNA in a microarray of ~10,000 spots with no diffusion during three hours incubation. Using the device to probe for an autoantibody cancer biomarker in blood serum sample gave five times higher signal to background ratio compared to standard protein microarray expressed on a flat microscope slide. Physical design principles to effectively fill the array of microreactors with reagent and experimental results of alternate methods for sealing the microreactors are presented.

  13. Digital communication device

    DEFF Research Database (Denmark)

    2005-01-01

    The invention concerns a digital communication device like a hearing aid or a headset. The hearing aid or headset has a power supply, a signal processing device, means for receiving a wireless signal and a receiver or loudspeaker, which produces an audio signal based on a modulated pulsed signal...... with high frequency shifting rate produced by the signal processing device. Further the receiver has a first and a second connection point for receiving the pulsed modulated signal wherein the sound producing parts of the receiver are at least partially enclosed by a metal box, whereby a third...... connection point is provided which is in electrical contact with the metal of the metal box and whereby this third connection point is connected to the electric circuitry of the communication device at a point having a stable and well defined electrical potential. In this way the electro-and magnetic...

  14. Medical Device Safety

    Science.gov (United States)

    ... Communication Date Mycobacterium chimaera Infections Associated with Sorin Group Deutschland GmbH Stӧckert 3T Heater-Cooler System: FDA Safety Communication 06/01/16 More Medical Device Safety Communications ...

  15. MDR (Medical Device Reporting)

    Data.gov (United States)

    U.S. Department of Health & Human Services — This database allows you to search the CDRH's database information on medical devices which may have malfunctioned or caused a death or serious injury during the...

  16. Advanced underwater lift device

    Science.gov (United States)

    Flanagan, David T.; Hopkins, Robert C.

    1993-01-01

    Flexible underwater lift devices ('lift bags') are used in underwater operations to provide buoyancy to submerged objects. Commercially available designs are heavy, bulky, and awkward to handle, and thus are limited in size and useful lifting capacity. An underwater lift device having less than 20 percent of the bulk and less than 10 percent of the weight of commercially available models was developed. The design features a dual membrane envelope, a nearly homogeneous envelope membrane stress distribution, and a minimum surface-to-volume ratio. A proof-of-concept model of 50 kg capacity was built and tested. Originally designed to provide buoyancy to mock-ups submerged in NASA's weightlessness simulators, the device may have application to water-landed spacecraft which must deploy flotation upon impact, and where launch weight and volume penalties are significant. The device may also be useful for the automated recovery of ocean floor probes or in marine salvage applications.

  17. Burst-Disk Device Simulates Effect Of Pyrotechnic Device

    Science.gov (United States)

    Rogers, James P.; Sexton, James H.

    1995-01-01

    Expendable disks substituted for costly pyrotechnic devices for testing actuators. Burst-disk device produces rush of pressurized gas similar to pyrotechnic device. Designed to reduce cost of testing pyrotechnically driven emergency actuators (parachute-deploying mechanisms in original application).

  18. Resources: Handheld Computing Devices

    OpenAIRE

    Denson, Cameron

    2008-01-01

    The article features a valuable resource to aid teachers in their effort to satisfy the need to implement modern instructional technology and their students' need to access green technology. It states that handheld computing devices are currently being widely used in many classrooms and technology savvy educators can manifest to the benefits of these data-collection systems. It believes that handheld units can offer students with an all-inclusive technological device that caters to all learners.

  19. Holographic liquid crystal devices

    OpenAIRE

    Pavani, Kotakonda, (Thesis)

    2009-01-01

    Liquid crystals have become natural candidates for use in electro-optic devices for their ability to change the orientation of the director with the application of an electric field, and exhibiting large range of refractive index. The aim of the work presented in this thesis is to fabricate liquid crystal optoelectronic devices such as electrically switchable liquid crystal diffraction gratings and polarization rotators by exploiting the holographic surface relief effect in photopolymer and b...

  20. Digital Devices: Nine Theses

    OpenAIRE

    Law, John; Ruppert, Evelyn; Savage, Mike

    2010-01-01

    The aim of the paper is to intervene in debates about the digital and in particular three kinds of framings: those that imagine the digital in terms of epochal shifts, or as representing a new era of mobility and flow, or as redefining life. Instead, we explore the lively, productive and performative qualities of the digital by attending to the specificities of digital devices and how they interact, and sometimes compete, with older devices and their capacity to mobilise and materialise socia...

  1. Nanoplasmonics advanced device applications

    CERN Document Server

    Chon, James W M

    2013-01-01

    Focusing on control and manipulation of plasmons at nanometer dimensions, nanoplasmonics combines the strength of electronics and photonics, and is predicted to replace existing integrated circuits and photonic devices. It is one of the fastest growing fields of science, with applications in telecommunication, consumer electronics, data storage, medical diagnostics, and energy.Nanoplasmonics: Advanced Device Applications provides a scientific and technological background of a particular nanoplasmonic application and outlines the progress and challenges of the application. It reviews the latest

  2. Inverted organic photosensitive device

    Energy Technology Data Exchange (ETDEWEB)

    Forrest, Stephen R.; Tong, Xiaoran; Lee, Jun Yeob; Cho, Yong Joo

    2015-09-08

    There is disclosed a method for preparing the surface of a metal substrate. The present disclosure also relates to an organic photovoltaic device including a metal substrate made by such method. Also disclosed herein is an inverted photosensitive device including a stainless steel foil reflective electrode, an organic donor-acceptor heterojunction over the reflective electrode, and a transparent electrode over the donor-acceptor heterojunction.

  3. Projection and registration device

    OpenAIRE

    Verlinden, J.C.

    2009-01-01

    A projection and recording device, provided with a processing and control unit, a memory for recording images and other data, an input/output interface, a controllable camera, a touch screen for the input and display of data and images, a position determining system for determining the position of at least one object in relation to the projection and recording device, with images recorded by the camera being storable in the memory and displayable on the touch screen, and a projector for proje...

  4. Electronic security device

    International Nuclear Information System (INIS)

    The present invention relates to a security device having a control box containing an electronic system and a communications loop over which the system transmits a signal. The device is constructed so that the communications loop can extend from the control box across the boundary of a portal such as a door into a sealed enclosure into which access is restricted whereby the loop must be damaged or moved in order for an entry to be made into the enclosure. The device is adapted for detecting unauthorized entries into such enclosures such as rooms or containers and for recording the time at which such entries occur for later reference. Additionally, the device detects attempts to tamper or interfere with the operation of the device itself and records the time at which such events take place. In the preferred embodiment, the security device includes a microprocessor-based electronic system and a detection module capable of registering changes in the voltage and phase of the signal transmitted over the loop. 11 figs

  5. Organic 'Plastic' Optoelectronic Devices

    International Nuclear Information System (INIS)

    Recent developments on conjugated polymer based photovoltaic diodes and photoactive organic field effect transistors (photOFETs) are discussed. The photophysics of such devices is based on the photoinduced charge transfer from donor type semiconducting conjugated polymers onto acceptor type conjugated polymers or acceptor molecules such as Buckminsterfullerene, C60. Potentially interesting applications include sensitization of the photoconductivity and photovoltaic phenomena as well as photoresponsive organic field effect transistors (photOFETs). Furthermore, organic polymeric/inorganic nanoparticle based 'hybrid' solar cells will be discussed. This talk gives an overview of materials' aspect, charge-transport, and device physics of organic diodes and field-effect transistors. Furthermore, due to the compatibility of carbon/hydrogen based organic semiconductors with organic biomolecules and living cells there can be a great opportunity to integrate such organic semiconductor devices (biOFETs) with the living organisms. In general the largely independent bio/lifesciences and information technology of today, can be thus bridged in an advanced cybernetic approach using organic semiconductor devices embedded in bio-lifesciences. This field of bio-organic electronic devices is proposed to be an important mission of organic semiconductor devices

  6. Reactor power control device

    International Nuclear Information System (INIS)

    The present invention provides a control device which can conduct scram and avoid lowering of the power of a nuclear power plant upon occurrence of earthquakes. Namely, the device of the present invention comprises, in addition to an existent power control device, (1) an earthquake detector for detecting occurrence and annihilation of earthquakes and (2) a reactor control device for outputting control rod operation signals and reactor core flow rate control signals depending on the earthquake detection signals from the detector, and reactor and plant information. With such a constitution, although the reactor is vibrated by earthquakes, the detector detects slight oscillations of the reactor by initial fine vibration waves as premonitory symptoms of serious earthquakes. The earthquake occurrence signals are outputted to the reactor control device. The reactor control device, receiving the signals, changes the position of control rods by way of control rod driving mechanisms to make the axial power distribution in the reactor core to a top peak type. As a result, even if the void amount in the reactor core is reduced by the subsequent actual earthquakes, since the void amount is moved, effects on the increase of neutron fluxes by the actual earthquakes is small. (I.S.)

  7. Alternative Devices for Taking Insulin

    Science.gov (United States)

    ... KB). Alternate Language URL Alternative Devices for Taking Insulin Page Content On this page: What alternative devices ... the skin. [ Top ] What alternative devices for taking insulin are available? Insulin pens provide a convenient, easy- ...

  8. Cataphoric devices in spoken discourse.

    Science.gov (United States)

    Gernsbacher, M A; Jescheniak, J D

    1995-08-01

    We propose that speakers mark key words with cataphoric devices. Cataphoric devices are counterparts to anaphoric devices: Just as anaphoric devices enable backward reference, cataphoric devices enable forward reference. And just as anaphoric devices mark concepts that have been mentioned before, cataphoric devices mark concepts that are likely to be mentioned again. We investigated two cataphoric devices: spoken stress and the indefinite this. Our experiments demonstrated three ways that concepts marked by cataphoric devices gain a privileged status in listeners' mental representations: Cataphoric devices enhance the activation of the concepts that they mark; cataphoric devices suppress the activation of previously mentioned concepts; and cataphoric devices protect the concepts that they mark from being suppressed by subsequently mentioned concepts. PMID:7641525

  9. Diamond Electronic Devices

    International Nuclear Information System (INIS)

    For high-power and high-voltage applications, silicon is by far the dominant semiconductor material. However, silicon has many limitations, e.g. a relatively low thermal conductivity, electric breakdown occurs at relatively low fields and the bandgap is 1.1 eV which effectively limits operation to temperatures below 175 deg.n C. Wide-bandgap materials, such as silicon carbide (SiC), gallium nitride (GaN) and diamond offer the potential to overcome both the temperature and power handling limitations of silicon. Diamond is the most extreme in this class of materials. By the fundamental material properties alone, diamond offers the largest benefits as a semiconductor material for power electronic applications. On the other hand, diamond has a problem with a large carrier activation energy of available dopants which necessitates specialised device concepts to allow room temperature (RT) operation. In addition, the role of common defects on the charge transport properties of diamond is poorly understood. Notwithstanding this, many proof-of-principle two-terminal and three-terminal devices have been made and tested. Two-terminal electronic diamond devices described in the literature include: p-n diodes, p-i-n diodes, various types of radiation detectors, Schottky diodes and photoconductive or electron beam triggered switches. Three terminal devices include e.g. MISFETs and JFETs. However, the development of diamond devices poses great challenges for the future. A particularly interesting way to overcome the doping problem, for which there has been some recent progress, is to make so-called delta doped (or pulse-doped) devices. Such devices utilise very thin (∼1 nm) doped layers in order to achieve high RT activation.

  10. Diamond Electronic Devices

    Science.gov (United States)

    Isberg, J.

    2010-11-01

    For high-power and high-voltage applications, silicon is by far the dominant semiconductor material. However, silicon has many limitations, e.g. a relatively low thermal conductivity, electric breakdown occurs at relatively low fields and the bandgap is 1.1 eV which effectively limits operation to temperatures below 175° C. Wide-bandgap materials, such as silicon carbide (SiC), gallium nitride (GaN) and diamond offer the potential to overcome both the temperature and power handling limitations of silicon. Diamond is the most extreme in this class of materials. By the fundamental material properties alone, diamond offers the largest benefits as a semiconductor material for power electronic applications. On the other hand, diamond has a problem with a large carrier activation energy of available dopants which necessitates specialised device concepts to allow room temperature (RT) operation. In addition, the role of common defects on the charge transport properties of diamond is poorly understood. Notwithstanding this, many proof-of-principle two-terminal and three-terminal devices have been made and tested. Two-terminal electronic diamond devices described in the literature include: p-n diodes, p-i-n diodes, various types of radiation detectors, Schottky diodes and photoconductive or electron beam triggered switches. Three terminal devices include e.g. MISFETs and JFETs. However, the development of diamond devices poses great challenges for the future. A particularly interesting way to overcome the doping problem, for which there has been some recent progress, is to make so-called delta doped (or pulse-doped) devices. Such devices utilise very thin (˜1 nm) doped layers in order to achieve high RT activation.

  11. Semiconductor device physics and simulation

    CERN Document Server

    Yuan, J S

    1998-01-01

    This volume provides thorough coverage of modern semiconductor devices -including hetero- and homo-junction devices-using a two-dimensional simulator (MEDICI) to perform the analysis and generate simulation results Each device is examined in terms of dc, ac, and transient simulator results; relevant device physics; and implications for design and analysis Two hundred forty-four useful figures illustrate the physical mechanisms and characteristics of the devices simulated Comprehensive and carefully organized, Semiconductor Device Physics and Simulation is the ideal bridge from device physics to practical device design

  12. Condensate filtering device

    International Nuclear Information System (INIS)

    In a condensate filtering device of a nuclear power plant, a water collecting pipe is disposed over the entire length, an end of a hollow thread is in communication with the water collecting pipe and secured. If the length of the water collecting pipe is extended, a filtering device of an optional length can be obtained irrespective of the length of the hollow thread. Therefore, since there is no need to connect units upon constituting a module, flow of cleaning gases is not restricted at connection portions. Accordingly, even if the volume of the device is increased by the extension of the module, the working life of the module is not degraded. (T.M.)

  13. Endoscopic Devices for Obesity.

    Science.gov (United States)

    Sampath, Kartik; Dinani, Amreen M; Rothstein, Richard I

    2016-06-01

    The obesity epidemic, recognized by the World Health Organization in 1997, refers to the rising incidence of obesity worldwide. Lifestyle modification and pharmacotherapy are often ineffective long-term solutions; bariatric surgery remains the gold standard for long-term obesity weight loss. Despite the reported benefits, it has been estimated that only 1% of obese patients will undergo surgery. Endoscopic treatment for obesity represents a potential cost-effective, accessible, minimally invasive procedure that can function as a bridge or alternative intervention to bariatric surgery. We review the current endoscopic bariatric devices including space occupying devices, endoscopic gastroplasty, aspiration technology, post-bariatric surgery endoscopic revision, and obesity-related NOTES procedures. Given the diverse devices already FDA approved and in development, we discuss the future directions of endoscopic therapies for obesity. PMID:27115879

  14. Pendulum detector testing device

    International Nuclear Information System (INIS)

    A detector testing device is described which provides consistent, cost-effective, repeatable results. The testing device is primarily constructed of PVC plastic and other non-metallic materials. Sensitivity of a walk-through detector system can be checked by: (1) providing a standard test object simulating the mass, size and material content of a weapon or other contraband, (2) suspending the test object in successive positions, such as head, waist and ankle levels, simulating where the contraband might be concealed on a person walking through the detector system; and (3) swinging the suspended object through each of the positions, while operating the detector system and observing its response. The test object is retained in a holder in which the orientation of the test device or target can be readily changed, to properly complete the testing requirements. 5 figs

  15. ALS insertion devices

    International Nuclear Information System (INIS)

    The Advanced Light Source (ALS), the first US third generation synchrotron radiation source, is currently under construction at the Lawrence Berkeley Laboratory. The low-emittance, 1.5 GeV electron storage ring and the insertion devices are specifically designed to produce high brightness beams in the UV to soft X-Ray range. The planned initial complement of insertion devices includes four 4.6 m long undulators, with period lengths of 3.9 cm, 5.0 cm (2) and 8.0 cm, and a 2.9 m long wiggler of 16 cm period length. Undulator design is well advanced and fabrication has begun on the 5.0 cm and 8.0 cm period length undulators. This paper discusses ALS insertion device requirements; general design philosophy; and design of the magnetic structure, support structure/drive systems, control system and vacuum system. 18 refs., 9 figs., 5 tabs

  16. Control rod operation device

    International Nuclear Information System (INIS)

    Purpose: To reduce operator's operation burdens in the low power state, while moderate his mental burdens upon high power state for the operation of control rod operation device. Constitution: Coordinate of main control rods to be operated, aimed insertion and withdrawal positions and velocity are calculated by the control rod operation sequence and the control rod worth table, to output a control rod selection signal and a control rod operation signal. The control rod operation device conducts extraction or insertion of control rods by these signals. In this way, the operator can automatically operate the control rods by merely manipulating the control rod operation device, by which the operator's operation burden can be reduced in low power state. Further, since the selection of the control rods, the operation speed, etc. are judged by an electronic computer also upon high reactor power state, operator's metal burdens can be moderated. (Kamimura, M.)

  17. Evolution of Growth Hormone Devices: Matching Devices with Patients.

    Science.gov (United States)

    Raimer-Hall, Dawn; Shea, Heidi Chamberlain

    2015-01-01

    Self-injection of growth hormone (GH) by children with GH deficiency can be problematic. They may have difficulty manipulating injection devices or preparing medication, and injections can be painful and create anxiety. Adherence to daily GH injections optimizes treatment benefit. Studies indicate that injection pens or needle-free devices enable easy self-injection by children, minimize medication reconstitution and storage requirements, and reduce injection pain. Newer GH delivery devices potentially encourage improved patient adherence. Reviewing features of GH devices will help nurses decide which GH device best fits the needs and abilities of pediatric patients. We searched recent medical literature about GH device development, about device-associated patient preferences and treatment adherence, and comparisons among GH devices. We concluded that improved awareness of the strengths and limitations of GH devices will enable nurses to guide families in selecting and using GH devices, improving adherence and outcomes, and helping children reach full growth potential. PMID:26292454

  18. Nanoelectromechanics of shuttle devices

    Science.gov (United States)

    Shekhter, R. I.; Gorelik, L. Y.; Krive, I. V.; Kiselev, M. N.; Parafilo, A. V.; Jonson, M.

    2013-04-01

    A single-electron tunneling (SET) device with a nanoscale central island that can move with respect to the bulk sourceand drain electrodes allows for a nanoelectromechanical (NEM) coupling between the electrical current through the device and the mechanical vibrations of the island. Although the electromechanical "shuttle" instability and the associated phenomenon of single-electron shuttling were predicted more than 15 years ago, both theoretical and experimental studies of NEM-SET structures are still carried out. New functionalities based on quantum coherence, Coulomb correlations and coherent electron-spin dynamics are still of particular interest. In this article we present a short review of recent activities in this area.

  19. Electronic control devices

    International Nuclear Information System (INIS)

    The translation of data from particle detectors into computercomprehensible form is reviewed. Following a brief account of the electronics of particle-detectors, the author describes the types of data-acquisition systems now or soon-to-be available. THe CAMAC system, a currently available computer aided control device, is discussed first. The possibility of a design-it-yourself system is dealt with next, with design parameters and practical pointers given that are drawn from the authors personal experience. Finally, the trigger systems of these devices are described and the prospects of a new system still in development, called FASTBUS, are given

  20. Electronic devices and circuits

    CERN Document Server

    Pridham, Gordon John

    1968-01-01

    Electronic Devices and Circuits, Volume 1 deals with the design and applications of electronic devices and circuits such as passive components, diodes, triodes and transistors, rectification and power supplies, amplifying circuits, electronic instruments, and oscillators. These topics are supported with introductory network theory and physics. This volume is comprised of nine chapters and begins by explaining the operation of resistive, inductive, and capacitive elements in direct and alternating current circuits. The theory for some of the expressions quoted in later chapters is presented. Th

  1. Asphaltene based photovoltaic devices

    Science.gov (United States)

    Chianelli, Russell R.; Castillo, Karina; Gupta, Vipin; Qudah, Ali M.; Torres, Brenda; Abujnah, Rajib E.

    2016-03-22

    Photovoltaic devices and methods of making the same, are disclosed herein. The cell comprises a photovoltaic device that comprises a first electrically conductive layer comprising a photo-sensitized electrode; at least one photoelectrochemical layer comprising metal-oxide particles, an electrolyte solution comprising at least one asphaltene fraction, wherein the metal-oxide particles are optionally dispersed in a surfactant; and a second electrically conductive layer comprising a counter-electrode, wherein the second electrically conductive layer comprises one or more conductive elements comprising carbon, graphite, soot, carbon allotropes or any combinations thereof.

  2. INLET STRATIFICATION DEVICE

    DEFF Research Database (Denmark)

    2006-01-01

    An inlet stratification device (5) for a circuit circulating a fluid through a tank (1 ) and for providing and maintaining stratification of the fluid in the tank (1 ). The stratification de- vice (5) is arranged vertically in the tank (1) and comprises an inlet pipe (6) being at least partially...... formed of a flexible porous material and having an inlet (19) and outlets formed of the pores of the porous material. The stratification device (5) further comprises at least one outer pipe (7) surrounding the inlet pipe (6) in spaced relationship thereto and being at least partially formed of a porous...

  3. Inlet stratification device

    DEFF Research Database (Denmark)

    2014-01-01

    An inlet stratification (5) is adapted to be arranged vertically in a tank (1) during operation. The stratification device (5) comprises an inlet pipe (6) formed of a flexible porous material and having a lower and upper end. The lower end of the inlet pipe (6) is connected to a bottom cap (10......) with an inlet passage way (16). The upper end of the inlet pipe (6) is connected with a top cap (9). The top cap (9) and the bottom cap (10) are mutually connected by means of a wire (8) and the top cap (9) is configured as a floating device providing a buoyancy force larger than the downwardly...

  4. Microwave Magnetoelectric Devices

    OpenAIRE

    Tatarenko, A. S.; Bichurin, M. I.

    2012-01-01

    Tunable microwave magnetoelectric devices based on layered ferrite-ferroelectric structures are described. The theory and experiment for attenuator, band-pass filter and phase shifter are presented. Tunability of the ME devices characteristics can be executed by application of an electric field. This electric tuning is relatively fast and is not power-consuming. The attenuator insertion losses vary from 26 dB to 2 dB at frequency 7251 MHz. The tuning range of 25 MHz of band-pass filter at fre...

  5. Graphene field emission devices

    OpenAIRE

    DUESBERG, GEORG

    2014-01-01

    PUBLISHED Graphene field emission devices are fabricated using a scalable process. The field enhancement factors, determined from the Fowler-Nordheim plots, are within few hundreds and match the theoretical predictions. The devices show high emission current density of ∼10 nA μm−1 at modest voltages of tens of volts. The emission is stable with time and repeatable over long term, whereas the noise in the emission current is comparable to that from individual carbon nanotubes emitting under...

  6. Preventing medical device recalls

    CERN Document Server

    Raheja, Dev

    2014-01-01

    Introduction to Medical Device RequirementsIntroductionThe ChallengesSources of ErrorsUnderstanding the Science of Safety     Overview of FDA Quality System Regulation     Overview of Risk Management Standard ISO 14971     Overview of FDA Device Approval Process     Overview of Regulatory Requirements for Clinical TrialsSummaryReferencesPreventing Recalls during Specification WritingIntroductionConduct Requirements Analysis to Identify Missing RequirementsSpecifications for Safety, Durability, and

  7. Nanoscale memory devices

    International Nuclear Information System (INIS)

    This article reviews the current status and future prospects for the use of nanomaterials and devices in memory technology. First, the status and continuing scaling trends of the flash memory are discussed. Then, a detailed discussion on technologies trying to replace flash in the near-term is provided. This includes phase change random access memory, Fe random access memory and magnetic random access memory. The long-term nanotechnology prospects for memory devices include carbon-nanotube-based memory, molecular electronics and memristors based on resistive materials such as TiO2. (topical review)

  8. Phononic crystal devices

    Science.gov (United States)

    El-Kady, Ihab F.; Olsson, Roy H.

    2012-01-10

    Phononic crystals that have the ability to modify and control the thermal black body phonon distribution and the phonon component of heat transport in a solid. In particular, the thermal conductivity and heat capacity can be modified by altering the phonon density of states in a phononic crystal. The present invention is directed to phononic crystal devices and materials such as radio frequency (RF) tags powered from ambient heat, dielectrics with extremely low thermal conductivity, thermoelectric materials with a higher ratio of electrical-to-thermal conductivity, materials with phononically engineered heat capacity, phononic crystal waveguides that enable accelerated cooling, and a variety of low temperature application devices.

  9. Microfluidic Cell Culture Device

    Science.gov (United States)

    Takayama, Shuichi (Inventor); Cabrera, Lourdes Marcella (Inventor); Heo, Yun Seok (Inventor); Smith, Gary Daniel (Inventor)

    2014-01-01

    Microfluidic devices for cell culturing and methods for using the same are disclosed. One device includes a substrate and membrane. The substrate includes a reservoir in fluid communication with a passage. A bio-compatible fluid may be added to the reservoir and passage. The reservoir is configured to receive and retain at least a portion of a cell mass. The membrane acts as a barrier to evaporation of the bio-compatible fluid from the passage. A cover fluid may be added to cover the bio-compatible fluid to prevent evaporation of the bio-compatible fluid.

  10. Underwater running device

    International Nuclear Information System (INIS)

    An underwater running device for an underwater inspection device for detecting inner surfaces of a reactor or a water vessel has an outer frame and an inner frame, and both of them are connected slidably by an air cylinder and connected rotatably by a shaft. The outer frame has four outer frame legs, and each of the outer frame legs is equipped with a sucker at the top end. The inner frame has four inner frame legs each equipped with a sucker at the top end. The outer frame legs and the inner frame legs are each connected with the outer frame and the inner frame by the air cylinder. The outer and the inner frame legs can be elevated or lowered (or extended or contracted) by the air cylinder. The sucker is connected with a jet pump-type negative pressure generator. The device can run and move by repeating attraction and releasing of the outer frame legs and the inner frame legs alternately while maintaining the posture of the inspection device stably. (I.N.)

  11. Neutron measuring device

    International Nuclear Information System (INIS)

    The device of the present invention concerns measurement for neutrons in a tokamak type thermonuclear device and it can measure total amount of generated neutrons accurately throughout the operation period even if an error is caused in counted values by plasma disruption. That is, the device comprises (1) a means for detecting presence or absence of occurrence of plasma disruption and the time for the initiation of the occurrence, (2) a first data processing means for processing detection signals, (3) a means for detecting neutrons generated in plasmas and (4) a second data processing means for calculating integrated values for the number of neutrons generated from the start to the completion of electric discharge when no disruption occurs and calculating integrated values for the number of generated neutrons from the start of electric discharge to the time at the initiation of occurrence of the disruption when disruption is present. In the thus constituted device, even if an error is caused by frequent occurrence of plasma disruption, total time integrated amount of neutrons generated in the plasmas can be measured accurately. (I.S.)

  12. Road-Cleaning Device

    Science.gov (United States)

    Roman, Harry T.

    2014-01-01

    Roadways are literally soaked with petrochemical byproducts, oils, gasoline, and other volatile substances that eventually run off into sewers and end up in rivers, waterways, and other undesirable places. Can the roads be cleaned of these wastes, with their proper disposal? Can vehicles, robots, or other devices be designed that could be driven…

  13. Device Oriented Project Controller

    Energy Technology Data Exchange (ETDEWEB)

    Dalesio, Leo; Kraimer, Martin

    2013-11-20

    This proposal is directed at the issue of developing control systems for very large HEP projects. A de-facto standard in accelerator control is the Experimental Physics and Industrial Control System (EPICS), which has been applied successfully to many physics projects. EPICS is a channel based system that requires that each channel of each device be configured and controlled. In Phase I, the feasibility of a device oriented extension to the distributed channel database was demonstrated by prototyping a device aware version of an EPICS I/O controller that functions with the current version of the channel access communication protocol. Extensions have been made to the grammar to define the database. Only a multi-stage position controller with limit switches was developed in the demonstration, but the grammar should support a full range of functional record types. In phase II, a full set of record types will be developed to support all existing record types, a set of process control functions for closed loop control, and support for experimental beam line control. A tool to configure these records will be developed. A communication protocol will be developed or extensions will be made to Channel Access to support introspection of components of a device. Performance bench marks will be made on both communication protocol and the database. After these records and performance tests are under way, a second of the grammar will be undertaken.

  14. Radiation flux measuring device

    International Nuclear Information System (INIS)

    A radiation flux measuring device is described which employs an attenuator circuit, the output of which is maintained constant, connected to a radiation detector. Means connected to the attenuator circuit produce an output representing the log of the a-c component of the radiation detector, thereby providing a true root mean square logarithmic output

  15. Radiation flux measuring device

    International Nuclear Information System (INIS)

    A radiation flux measuring device is described which employs a differential pair of transistors, the output of which is maintained constant, connected to a radiation detector. Means connected to the differential pair produce a signal representing the log of the a-c component of the radiation detector, thereby providing a signal representing the true root mean square logarithmic output. 3 claims, 2 figures

  16. A Medical Delivery Device

    DEFF Research Database (Denmark)

    2010-01-01

    The present invention relates to a medical delivery device comprising at least two membrane electrode assembly units each of which comprises three layers: an upper and a lower electrode and a selective ionic conductive membrane provided there-between. At least one of the three layers are shared by...

  17. Wavelength conversion devices

    DEFF Research Database (Denmark)

    Mikkelsen, Benny; Durhuus, Terji; Jørgensen, Carsten;

    1996-01-01

    Summary form only given. Wavelength converters will be essential devices to exploit the full potential of the wavelength dimension in wavelength-division multiplexed (WDM) networks. Based on experiments, we discuss different candidates for efficient wavelength converters with attention to expected...

  18. Spark ablation device

    NARCIS (Netherlands)

    Schmidt-Ott, A.; Pfeiffer, T.V.

    2013-01-01

    A spark ablation device for generating nanoparticles comprising a spark generator; the spark generator comprising first and second electrodes, wherein the spark generator further comprises at least one power source which is arranged to be operative at a first energy level for maintaining a discharge

  19. Emergency core cooling device

    International Nuclear Information System (INIS)

    The present invention provides an emergency core cooling device without using a reactor core spray device, in which the reactor core of a BWR type reactor is cooled effectively and certainly by flooding of the reactor core. That is, the emergency core cooling device comprises a high pressure core water injection system as an emergency core cooling system (ECCS) for cooling the inside of the reactor core upon loss of coolants accident (LOCA). By means of the high pressure core water injection system, water is injected from a condensate storage vessel or a suppression pool to the inside of the reactor core shroud upon LOCA. Accordingly, the reactor core is cooled effectively by reactor core flooding. In this device, cooling water can be injected to the inside of the reactor core shroud by means of the high pressure core injection system upon LOCA in which the coolants are discharged from the outside of the reactor core shroud. On the other hand, upon LOCA in which the coolants are discharged from the inside of the reactor core shroud, the cooling water can be supplied to the reactor core by means of a cooling system upon reactor isolation which injects water to the outside of the reactor core or a low pressure water injection system. (I.S.)

  20. Tritium removing device

    International Nuclear Information System (INIS)

    Tritium-containing gases in a reactor container are discharged to a gas pressurizer and the gases pressurized there are sent to the primary side of a tritium separation device under a high or low pressure. Polyimide polymer separation membranes having selective permeability to elemental tritium and tritium vapor are coated in the tritium separation device. The separation device is divided into primary and secondary sides by the separation membranes and the pressure in the secondary side is lowered by a vacuum pump, etc. Tritium contained in the tritium-containing gases passes through the separation membranes selectively to be moved into the secondary side. Accordingly, tritium is treated in the elemental form and equipments for regeneration such as an adsorption column, etc. are no more necessary and the space can be saved due to minimization of the removing device. Further, since tritium can be removed continuously without storing a great amount of tritium, it is preferable in view of safety. (T.M.)

  1. Air Stable Photovoltaic Device

    DEFF Research Database (Denmark)

    2010-01-01

    A method of forming a conducting polymer based photovoltaic device comprising the steps of : (a) providing a transparent first electrode; (b) providing the transparent first electrode with a layer of metal oxide nanoparticles, wherein the metal oxide is selected from the group consisting of : TiO...

  2. Devic's Disease (Neuromyelitis optical)

    International Nuclear Information System (INIS)

    We present a case report about a young woman initially treated as having multiple sclerosis, who relapsed with serious visual impairment. Devic's disease is a demyelinating disorder that presents as transverse myelitis associated with optic neuritis, typically bilateral. Multiple sclerosis is in fact the main differential diagnosis

  3. Device configuration-management system

    International Nuclear Information System (INIS)

    The Fusion Chamber System, a major component of the Magnetic Fusion Test Facility, contains several hundred devices which report status to the Supervisory Control and Diagnostic System for control and monitoring purposes. To manage the large number of diversity of devices represented, a device configuration management system was required and developed. Key components of this software tool include the MFTF Data Base; a configuration editor; and a tree structure defining the relationships between the subsystem devices. This paper will describe how the configuration system easily accomodates recognizing new devices, restructuring existing devices, and modifying device profile information

  4. Cybersecurity for Connected Diabetes Devices

    OpenAIRE

    Klonoff, David C.

    2015-01-01

    Diabetes devices are increasingly connected wirelessly to each other and to data-displaying reader devices. Threats to the accurate flow of information and commands may compromise the function of these devices and put their users at risk of health complications. Sound cybersecurity of connected diabetes devices is necessary to maintain confidentiality, integrity, and availability of the data and commands. Diabetes devices can be hacked by unauthorized agents and also by patients themselves to...

  5. Radioactive waste processing device

    International Nuclear Information System (INIS)

    Liquid wastes are supplied to a ceramic filter to conduct filtration. In this case, a device for adding a powdery inorganic ion exchanger is disposed to the upstream of the ceramic filter. When the powdery inorganic ion exchanger is charged to the addition device, it is precoated to the surface of the ceramic filter, to conduct separation of suspended matters and separation of ionic nuclides simultaneously. Liquid wastes returned to a collecting tank are condensed while being circulated between the ceramic filter and the tank and then contained in a condensation liquid waste tank. With such a constitution, both of radioactive nuclides accompanied by suspended matters in the radioactive liquid wastes and ionic nuclides can be captured efficiently. (T.M.)

  6. Organic photosensitive devices

    Science.gov (United States)

    Peumans, Peter; Forrest, Stephen R.

    2013-01-22

    A photoactive device is provided. The device includes a first electrode, a second electrode, and a photoactive region disposed between and electrically connected to the first and second electrodes. The photoactive region further includes an organic donor layer and an organic acceptor layer that form a donor-acceptor heterojunction. The mobility of holes in the organic donor region and the mobility of electrons in the organic acceptor region are different by a factor of at least 100, and more preferably a factor of at least 1000. At least one of the mobility of holes in the organic donor region and the mobility of electrons in the organic acceptor region is greater than 0.001 cm.sup.2/V-sec, and more preferably greater than 1 cm.sup.2/V-sec. The heterojunction may be of various types, including a planar heterojunction, a bulk heterojunction, a mixed heterojunction, and a hybrid planar-mixed heterojunction.

  7. Integrated elastic microscope device

    Science.gov (United States)

    Lee, W. M.; Wright, D.; Watkins, R.; Cen, Zi

    2015-03-01

    The growing power of imaging and computing power of smartphones is creating the possibility of converting your smartphone into a high power pocket microscopy system. High quality miniature microscopy lenses attached to smartphone are typically made with glass or plastics that can only be produce at low cost with high volume. To revise the paradigm of microscope lenses, we devised a simple droplet lens fabrication technique that which produces low cost and high performance lens. Each lens is integrated into thin 3-D printed holder with complimentary light emitted diode (LEDs) that clips onto majority of smartphones. The integrated device converts a smartphone into a high power optical microscope/dermatoscope at around $2. This low cost device has wide application in a multitude of practical uses such as material inspection, dermascope and educational microscope.

  8. Microelectromechanical reprogrammable logic device

    Science.gov (United States)

    Hafiz, M. A. A.; Kosuru, L.; Younis, M. I.

    2016-03-01

    In modern computing, the Boolean logic operations are set by interconnect schemes between the transistors. As the miniaturization in the component level to enhance the computational power is rapidly approaching physical limits, alternative computing methods are vigorously pursued. One of the desired aspects in the future computing approaches is the provision for hardware reconfigurability at run time to allow enhanced functionality. Here we demonstrate a reprogrammable logic device based on the electrothermal frequency modulation scheme of a single microelectromechanical resonator, capable of performing all the fundamental 2-bit logic functions as well as n-bit logic operations. Logic functions are performed by actively tuning the linear resonance frequency of the resonator operated at room temperature and under modest vacuum conditions, reprogrammable by the a.c.-driving frequency. The device is fabricated using complementary metal oxide semiconductor compatible mass fabrication process, suitable for on-chip integration, and promises an alternative electromechanical computing scheme.

  9. Internal pump monitoring device

    International Nuclear Information System (INIS)

    In the present invention, a thermometer is disposed at the upper end of an internal pump casing of a coolant recycling system in a BWR type reactor to detect leakage of reactor water thereby ensuring the improvement of reliability of the internal pump. Namely, a thermometer is disposed, which can detect temperature elevation occurred when water in the internal pump leaked from a reactor pressure vessel passes through the gap between a stretch tube and an upper end of the pump casing. Signals from the thermometer are transmitted to a signal processing device by an instrumentation cable. The signal processing device generates an alarm when the temperature signal exceeds a predetermined value and announces that leakage of reactor water occurs in the internal pump. Since the present invention can detect the leakage of the reactor water in the pump casing in an early stage, it can contribute to the improvement of the safety and reliability of the internal pump. (I.S.)

  10. Anti-gravity device

    Science.gov (United States)

    Palsingh, S. (Inventor)

    1975-01-01

    An educational toy useful in demonstrating fundamental concepts regarding the laws of gravity is described. The device comprises a sphere 10 of radius r resting on top of sphere 12 of radius R. The center of gravity of sphere 10 is displaced from its geometrical center by distance D. The dimensions are so related that D((R+r)/r) is greater than r. With the center of gravity of sphere 10 lying on a vertical line, the device is in equilibrium. When sphere 10 is rolled on the surface of sphere 12 it will return to its equilibrium position upon release. This creates an illusion that sphere 10 is defying the laws of gravity. In reality, due to the above noted relationship of D, R, and r, the center of gravity of sphere 10 rises from its equilibrium position as it rolls a short distance up or down the surface of sphere 12.

  11. Microelectromechanical safe arm device

    Energy Technology Data Exchange (ETDEWEB)

    Roesler, Alexander W. (Tijeras, NM)

    2012-06-05

    Microelectromechanical (MEM) apparatus and methods for operating, for preventing unintentional detonation of energetic components comprising pyrotechnic and explosive materials, such as air bag deployment systems, munitions and pyrotechnics. The MEM apparatus comprises an interrupting member that can be moved to block (interrupt) or complete (uninterrupt) an explosive train that is part of an energetic component. One or more latching members are provided that engage and prevent the movement of the interrupting member, until the one or more latching members are disengaged from the interrupting member. The MEM apparatus can be utilized as a safe and arm device (SAD) and electronic safe and arm device (ESAD) in preventing unintentional detonations. Methods for operating the MEM apparatus include independently applying drive signals to the actuators coupled to the latching members, and an actuator coupled to the interrupting member.

  12. Microelectromechanical reprogrammable logic device

    KAUST Repository

    Hafiz, M. A. A.

    2016-03-29

    In modern computing, the Boolean logic operations are set by interconnect schemes between the transistors. As the miniaturization in the component level to enhance the computational power is rapidly approaching physical limits, alternative computing methods are vigorously pursued. One of the desired aspects in the future computing approaches is the provision for hardware reconfigurability at run time to allow enhanced functionality. Here we demonstrate a reprogrammable logic device based on the electrothermal frequency modulation scheme of a single microelectromechanical resonator, capable of performing all the fundamental 2-bit logic functions as well as n-bit logic operations. Logic functions are performed by actively tuning the linear resonance frequency of the resonator operated at room temperature and under modest vacuum conditions, reprogrammable by the a.c.-driving frequency. The device is fabricated using complementary metal oxide semiconductor compatible mass fabrication process, suitable for on-chip integration, and promises an alternative electromechanical computing scheme.

  13. Thin film device applications

    CERN Document Server

    Kaur, Inderjeet

    1983-01-01

    Two-dimensional materials created ab initio by the process of condensation of atoms, molecules, or ions, called thin films, have unique properties significantly different from the corresponding bulk materials as a result of their physical dimensions, geometry, nonequilibrium microstructure, and metallurgy. Further, these characteristic features of thin films can be drasti­ cally modified and tailored to obtain the desired and required physical characteristics. These features form the basis of development of a host of extraordinary active and passive thin film device applications in the last two decades. On the one extreme, these applications are in the submicron dimensions in such areas as very large scale integration (VLSI), Josephson junction quantum interference devices, magnetic bubbles, and integrated optics. On the other extreme, large-area thin films are being used as selective coatings for solar thermal conversion, solar cells for photovoltaic conver­ sion, and protection and passivating layers. Ind...

  14. Particle capture device

    Energy Technology Data Exchange (ETDEWEB)

    Jayne, John T.; Worsnop, Douglas R.

    2016-02-23

    In example embodiments, particle collection efficiency in aerosol analyzers and other particle measuring instruments is improved by a particle capture device that employs multiple collisions to decrease momentum of particles until the particles are collected (e.g., vaporized or come to rest). The particle collection device includes an aperture through which a focused particle beam enters. A collection enclosure is coupled to the aperture and has one or more internal surfaces against which particles of the focused beam collide. One or more features are employed in the collection enclosure to promote particles to collide multiple times within the enclosure, and thereby be vaporized or come to rest, rather than escape through the aperture.

  15. Incore inspection device

    International Nuclear Information System (INIS)

    The device of the present invention can inspect surfaces of equipments in reactor water in a nuclear reactor in a state of atmospheric air. Namely, an inspection device is movable forwardly and backwardly in a water-proof vessel. An annular sucker with pleats is disposed to the outer side of a lid of the water-proof vessel. A television camera for an under water monitoring is disposed to the inner side of the lid of the water-proof vessel by way of a partitioning wall with lid. Transferring screws are disposed at the back and on the side of the water-proof vessel. In the device having such a constitution, (1) the inside of the water-proof vessel is at first made water-tight by closing the partitioning wall with lid, (2) the back and the side screws are operated by the guide of the underwater monitoring television camera, to transfer the water-proof vessel to the surface of the reactor core to be inspected, (3) the annular sucker with pleats is urged on the surface to be inspected by the back screw, to fix the water-proof vessel, (4) reactor water in a space of the annular sucker with pleats is discharged and replaced with air, and (5) the lid of the partition wall with lid is opened and the inspection device is disposed at a position of the underwater monitoring television camera, to inspect the surface to be inspected in a state of atmospheric air. (I.S.)

  16. Electronic devices and circuits

    CERN Document Server

    Kishore, K Lal

    2008-01-01

    This book is written in a simple lucid Language along with derivation of equations and supported by numerous solved problems to help the student to understand the concepts clearly.Advances in Miniaturization of Electronic Systems by ever increasing packaging densities on Integrated Circuits has made it very essential for thorough Knowledge of the concepts, phenomenon, characteristics and behaviour of semiconductor Devices for students and professionals.

  17. Novel Fouling Measurement Device

    OpenAIRE

    Sinčić, D.; Ribić, B.; Caharija, A.

    2015-01-01

    The novel device for measuring characteristics of the process that takes place when hydrocarbon liquids are subjected to elevated temperatures is described. The measuring cell has the form of a loop in which circulation is induced by a turbine stirrer. The stirrer contains magnets built into its blades, enabling mixing by a magnetic mixer positioned below the cell. No moving part protrudes from the cell. The fouling process takes place at the hot-wire probe positioned at the centre of the liq...

  18. Spintronics in nanoscale devices

    CERN Document Server

    Hedin, Eric R

    2013-01-01

    By exploiting the novel properties of quantum dots and nanoscale Aharonov-Bohm rings together with the electronic and magnetic properties of various semiconductor materials and graphene, researchers have conducted numerous theoretical and computational modeling studies and experimental tests that show promising behavior for spintronics applications. Spin polarization and spin-filtering capabilities and the ability to manipulate the electron spin state through external magnetic or electric fields have demonstrated the promise of workable nanoscale devices for computing and memory applications.

  19. Fluctuations in quantum devices

    Directory of Open Access Journals (Sweden)

    H.Haken

    2004-01-01

    Full Text Available Logical gates can be formalized by Boolean algebra whose elementary operations can be realized by devices that employ the interactions of macroscopic numbers of elementary excitations such as electrons, holes, photons etc. With increasing miniaturization to the nano scale and below, quantum fluctuations become important and can no longer be ignored. Based on Heisenberg equations of motion for the creation and annihilation operators of elementary excitations, I determine the noise sources of composite quantum systems.

  20. Fluctuations in quantum devices

    OpenAIRE

    Haken, H.

    2004-01-01

    Logical gates can be formalized by Boolean algebra whose elementary operations can be realized by devices that employ the interactions of macroscopic numbers of elementary excitations such as electrons, holes, photons etc. With increasing miniaturization to the nano scale and below, quantum fluctuations become important and can no longer be ignored. Based on Heisenberg equations of motion for the creation and annihilation operators of elementary excitations, I determine the noise sources of c...

  1. Hybrid electroluminescent devices

    Science.gov (United States)

    Shiang, Joseph John; Duggal, Anil Raj; Michael, Joseph Darryl

    2010-08-03

    A hybrid electroluminescent (EL) device comprises at least one inorganic diode element and at least one organic EL element that are electrically connected in series. The absolute value of the breakdown voltage of the inorganic diode element is greater than the absolute value of the maximum reverse bias voltage across the series. The inorganic diode element can be a power diode, a Schottky barrier diode, or a light-emitting diode.

  2. Designing sustainable medical devices

    OpenAIRE

    Marshall, J-L; Hinton, M; Wrobel, L; Troisi, G

    2009-01-01

    Stakeholders in the medical device manufacturing industry are becoming more concerned about the environmental impact of their products and processes. The consumers are also becoming more aware of the negative impact that manufacturers can have on the environment. Government initiatives continue to increase environmental awareness through the development of new policy and legislation, encouraging industry to become more accountable for the environmental impact of their products and operations....

  3. Memristor: the illusive device

    KAUST Repository

    Salama, Khaled N.

    2012-05-03

    The memristor (M) is considered to be the fourth two-terminal passive element in electronics, alongside the resistor (R), the capacitor (C), and the inductor (L). Its existence was postulated in 1971 but its first implementation was reported in 2008. Where was it hiding all that time and what can we do with it? Come and learn how the memristor completes the roster of electronic devices much like a missing particle that physicists seek to complete their tableaus.

  4. Fiber optic monitoring device

    Science.gov (United States)

    Samborsky, James K.

    1993-01-01

    A device for the purpose of monitoring light transmissions in optical fibers comprises a fiber optic tap that optically diverts a fraction of a transmitted optical signal without disrupting the integrity of the signal. The diverted signal is carried, preferably by the fiber optic tap, to a lens or lens system that disperses the light over a solid angle that facilitates viewing. The dispersed light indicates whether or not the monitored optical fiber or system of optical fibers is currently transmitting optical information.

  5. Mechanical Circulatory Assist Devices

    OpenAIRE

    Park, Sang B.; Magovern, George J.; Christlieb, Ignacio Y.; Kao, Race L.

    1987-01-01

    Cardiogenic shock occurs in about 10% of the 1.5 million patients who suffer myocardial infarction and in approximately 1% of the 200,000 patients who undergo open-heart surgery each year. The ventricular assist device decreases the workload of the failing ventricles and increases the blood flow through the coronary system. Recovery of failing myocardium after mechanical circulatory assistance has been well documented; however, the mechanisms that contribute to the recovery of a failing heart...

  6. A power measuring device

    International Nuclear Information System (INIS)

    As a part of the klystron test facility of the Dutch NIKHEF-K accelerator, a sensitive power measuring device has been built. The high-frequency power of a klystron is stored in a water-cooled dummy load. Using a microcomputer, the increase of the water temperature and the water flow rate are transformed to a digital indication of the klystron power. (Auth.)

  7. Electronic portal imaging devices

    International Nuclear Information System (INIS)

    The topics discussed include, among others, the following: Role of portal imaging; Port films vs. EPID; Image guidance: Elekta volume view; Delivery verification; Automation tasks of portal imaging; Types of portal imaging (Fluorescent screen, mirror, and CCD camera-based imaging; Liquid ion chamber imaging; Amorpho-silicon portal imagers; Fluoroscopic portal imaging; Kodak CR reader; and Other types of portal imaging devices); QA of EPID; and Portal dosimetry (P.A.)

  8. Incore instrument device

    International Nuclear Information System (INIS)

    An incore instrument device has an integrally disposed touch panel having a function of displaying an operation indication method such as for setting of conditions for incore measurement and information processing and results of the incore measurement and a function capable of conducting operation indication such as for setting conditions and information processing for incore measurement relative to a control section upon touching an information position on a displayed information. In addition, an information processing section comprising a man-machine function program formed so as to recognize the content of the operation indication for the incore measurement by touching and let the control section to conduct it is disposed to the outside by way of a communication interface. In addition, a programming device is disposed for forming and rewriting the program of the man-machine function relative to the information processing section. Then, when various indication operations are conducted upon performing incore measurement, a view point can be concentrated to one predetermined point thereby enabling to improve the operationability without danger. In addition, the programming of the man-machine function does not apply unnecessary load to the control section in the incore instrumentation device. (N.H.)

  9. Submarine inspection device

    International Nuclear Information System (INIS)

    The device of the present invention can confirm the assembly number of a fuel assembly in a pool and detect the head of an inserted material by a screen an image. That is, a submarine object is caused to swim by remote control by using a control device. A float which is floating on the water is disposed above the submarine object. A winch is disposed to the float for winding a rope such as a wire. The rope of the winch is connected to the submarine object. A TV camera is disposed to the float for photographing the submarine object. With such a constitution, the length of the rope can be controlled by the winch to restrict the moving range of the submarine object. This can prevent the submarine object from colliding against a fuel assembly or dropping. In addition, the position of the submarine object, which has been confirmed so far by a compass, a depth-sounding device and an image of TV camera appended to the submarine object, can be detected by the television images of the float extremely simply. (I.S.)

  10. Reactor water sampling device

    International Nuclear Information System (INIS)

    The present invention concerns a reactor water sampling device for sampling reactor water in an in-core monitor (neutron measuring tube) housing in a BWR type reactor. The upper end portion of a drain pipe of the reactor water sampling device is attached detachably to an in-core monitor flange. A push-up rod is inserted in the drain pipe vertically movably. A sampling vessel and a vacuum pump are connected to the lower end of the drain pipe. A vacuum pump is operated to depressurize the inside of the device and move the push-up rod upwardly. Reactor water in the in-core monitor housing flows between the drain pipe and the push-up rod and flows into the sampling vessel. With such a constitution, reactor water in the in-core monitor housing can be sampled rapidly with neither opening the lid of the reactor pressure vessel nor being in contact with air. Accordingly, operator's exposure dose can be reduced. (I.N.)

  11. Concrete peeling off device

    International Nuclear Information System (INIS)

    The present invention concerns a device for peeling off activated concretes in processing for discarding a reactor of a nuclear reactor facility. The device comprises a gyrotron for generation microwaves, an irradiator for irradiating output microwaves, a reflection mirror for reflecting and converging the microwaves and irradiating them to a material to be irradiated and a first rotating means for rotating the irradiator and the reflection mirror in parallel with the axis of the gyrotron while maintaining the positional relation between the irradiator and the reflection mirror. When the position of the microwaves irradiated on concrete walls are moved in a circumferential direction and the central axes of the rotational axis and the material to be irradiated are aligned, then the intensity of the irradiation of the microwaves at each of the irradiation points can be maintained constant without changing the focal distance of the reflected microwaves thereby enabling to peel off concretes efficiently. If operation conditions are controlled based on information such as temperature at the periphery of the microwave irradiation positions, the shape and the color of the material to be irradiated and the distance to the material to be irradiated, a concrete peeling off device of high reliability can be obtained. (N.H.)

  12. Rubber glove wearing device

    International Nuclear Information System (INIS)

    Rubber groves are attached each to an upper end of a glove putting vessel having an air-sucking hole on the bottom by enlarging an opening end of the rubber glove and turning back the inside to the outside. When the sucking device is operated, air in the glove putting device is sucked and the rubber glove is expanded by an atmospheric pressure. After expansion of the rubber glove to some extent, the sucking device is stopped, and presence or absence of failures of the rubber glove is confirmed by shrinkage of the rubber glove and by an indication value of a pressure gauge for detecting the pressure change in the vessel. Then, a hand is inserted to the expanded rubber glove, and a detaching switch in the vessel is pushed by a finger tip. A detaching piece at the upper end of the vessel is protruded outwardly to enlarge the turned-back portion of the rubber glove to easily release the rubber glove from the putting vessel, and the rubber glove is put on. This enables to wear the rubber glove and conduct failure test simultaneously. Further, a user can put on the rubber glove without touching the outside of the rubber glove. (I.N.)

  13. Electric dialysis device

    International Nuclear Information System (INIS)

    The device of the present invention can regenerate liquid salt wastes generated from a nuclear power plant into acid and alkali by electrolysis. Namely, the device has anion exchange membranes disposed in a cell. The inside of the cell is divided into an anode chamber and a cathode chamber. The anode chamber has an anode disposed therein. The cathode chamber has an impurity separating vessel and an cathode disposed therein. Liquid wastes flow into the impurity separating vessel, acid contents flow out of the anode chamber, and alkaline contents flow out of the cathode chamber. The device of the present invention has following advantages. (1) Since impurity separation for the liquid wastes and electric dialysis (acid and alkali separation) can be performed simultaneously, the process is simplified. (2) The amount of wastes generated can be reduced due to precipitation separation by hydrolysis separation of the impurities themselves. (3) Removal of the impurities can be performed only by exchange/disposal of the impurity separating vessel. (4) Since the impurities can be removed by back-wash of recovered acid, no secondary wastes are formed. (I.S.)

  14. Pruning devices in 1995

    International Nuclear Information System (INIS)

    This bulletin describes the market situation in April 1995 in Finland concerning devices suitable for silvicultural pruning in forestry. The review is based on the responses to a questionnaire sent to manufacturers and importers. Manually operated pruning devices, relying entirely on muscle power, were manufactured by six companies. There were four models each of branch saws and branch cutters and two models of branch blades. Motorised pruning devices, with the branch-severing power supplied by a combustion engine, battery or a power unit were manufactured by five companies. There were twelve models in all. The amount of pruning done in Finland has diminished year by year from the peak years of 1988-1989 when ca. 13000 hectares were pruned. In 1993 the corresponding figure was 5290 hectares of which 3930 hectares applied to private, non-industrial forestry. One contributing factor to this fall may be seen in the changes that have occurred in forest improvement regulations. The annual target set in the Forest 2000 program is for 20000 hectares to be pruned. (author)

  15. Reactor power measuring device

    International Nuclear Information System (INIS)

    The device of the present invention efficiently calibrates a fixed type gamma ray thermometer of a reactor power measuring device of a BWR type reactor. Namely, the device of the present invention calculates peripheral fuel rod power distribution by calibrating the reactor power distribution by heat generation amount, the reactor power distribution being obtained by a calculation based on a reactor model for converting the signals of a plurality of the gamma ray thermometers in the reactor core based on a conversion formula. In this case, the conversion formula is a relational formula between the power of a thermocouple of the gamma ray thermometer, gamma ray heat generation amount, thermocouple zero power sensitivity relative to a temperature coefficient. A conversion efficient calculation means makes a calibration heater to generate heat at a predetermined power, and the thermocouple zero power sensitivity and the temperature coefficient are obtained based on the output of the gamma ray thermometer in this case. The calibration means updates to conversion type thermocouple zero power sensitivity and temperature coefficient. A calibration execution means executes the operations described above successively, and when the thermocouple zero power sensitivity and the temperature coefficient are out of an allowable range, the means informs it and eliminates the corresponding gamma ray thermometer from the measuring meters. (I.S.)

  16. An introduction to electrooptic devices

    CERN Document Server

    Kaminow, Ivan P

    1974-01-01

    An Introduction to Electrooptic Devices aims to present an introduction to the electrooptic effect and to summarize work on devices employing the electrooptic effect. The book provides the necessary background in classical crystal optics. The text then discusses topics including crystal symmetry, the tensor description of linear dielectric properties, propagation in anisotropic media, and passive crystal optic devices. The book also describes the phenomenological description of tensor nonlinear dielectric properties of crystals, with emphasis on the electrooptic effect; device design and appli

  17. 78 FR 1247 - Certain Electronic Devices, Including Wireless Communication Devices, Tablet Computers, Media...

    Science.gov (United States)

    2013-01-08

    ... COMMISSION Certain Electronic Devices, Including Wireless Communication Devices, Tablet Computers, Media... United States after importation of certain electronic devices, including wireless communication devices... importation of certain electronic devices, including wireless communication devices, tablet computers,...

  18. Electromechanical motion devices

    CERN Document Server

    Krause, Paul C; Pekarek, Steven D

    2012-01-01

    This text provides a basic treatment of modern electric machine analysis that gives readers the necessary background for comprehending the traditional applications and operating characteristics of electric machines-as well as their emerging applications in modern power systems and electric drives, such as those used in hybrid and electric vehicles. Through the appropriate use of reference frame theory, Electromagnetic Motion Devices, Second Edition introduces readers to field-oriented control of induction machines, constant-torque, and constant-power control of dc, permanent-magnet ac

  19. Radiorespirometic assay device

    International Nuclear Information System (INIS)

    A radiorespirometic assay device is described in which the presence of microorganisms in a sample is determined by placing the sample in contact with a metabolisable radioactive labelled substrate, collecting any gas evolved, exposing a photosensitive material to the gas and determining if a spot is produced on the material. A spot indicates the presence of radioactivity showing that the substrate has been metabolized by a microorganism. Bacteria may be detected in body fluids, hospital operating rooms, water, food, cosmetics and drugs. (U.K.)

  20. COMMUNICATION - ORGANIZATIONS’ WORK DEVICE

    Directory of Open Access Journals (Sweden)

    LAVINIA HULEA

    2010-01-01

    Full Text Available Communication represents a complex process of transmitting messages, owing to which the emitter encodes the information transmitted through a specific channel towards a receiver that will decode it. Owing to communication, organizations transmit to their customers the fact that they are capable of meeting one of their needs, of settling a problem or of offering a profit. Non-verbal and para-verbal communications usually accompany verbal communication. The importance of assimilating the forms of communication is, at an organizational level, a complex device that determines the mastering of certain techniques, procedures, and algorithms of encoding and decoding intricate messages transmitted through various channels.

  1. Nanotube resonator devices

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Kenneth J; Zettl, Alexander K; Weldon, Jeffrey A

    2014-05-06

    A fully-functional radio receiver fabricated from a single nanotube is being disclosed. Simultaneously, a single nanotube can perform the functions of all major components of a radio: antenna, tunable band-pass filter, amplifier, and demodulator. A DC voltage source, as supplied by a battery, can power the radio. Using carrier waves in the commercially relevant 40-400 MHz range and both frequency and amplitude modulation techniques, successful music and voice reception has been demonstrated. Also disclosed are a radio transmitter and a mass sensor using a nanotube resonator device.

  2. Hybrid silicon evanescent devices

    Directory of Open Access Journals (Sweden)

    Alexander W. Fang

    2007-07-01

    Full Text Available Si photonics as an integration platform has recently been a focus of optoelectronics research because of the promise of low-cost manufacturing based on the ubiquitous electronics fabrication infrastructure. The key challenge for Si photonic systems is the realization of compact, electrically driven optical gain elements. We review our recent developments in hybrid Si evanescent devices. We have demonstrated electrically pumped lasers, amplifiers, and photodetectors that can provide a low-cost, scalable solution for hybrid integration on a Si platform by using a novel hybrid waveguide architecture, consisting of III-V quantum wells bonded to Si waveguides.

  3. Anisotropic metamaterial devices

    Directory of Open Access Journals (Sweden)

    Wei Xiang Jiang

    2009-12-01

    Full Text Available In the last few years, a rapid development has been achieved in a subject area, so called optical transformation, which is based on the property of metric invariance in Maxwell's equations. Optical transformation, also known as transformation optics, allows metamaterials to be tailor-made according to practical needs. In this paper, we have reviewed the recent progress on the parametric design of transformation devices, such as invisibility cloaks, electromagnetic (EM concentrator, EM-wave converter, etc. The technique of optical transformation can also be applied when the sources are included in the transformed space.

  4. Computed tomography device

    International Nuclear Information System (INIS)

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  5. Data mining mobile devices

    CERN Document Server

    Mena, Jesus

    2013-01-01

    With today's consumers spending more time on their mobiles than on their PCs, new methods of empirical stochastic modeling have emerged that can provide marketers with detailed information about the products, content, and services their customers desire.Data Mining Mobile Devices defines the collection of machine-sensed environmental data pertaining to human social behavior. It explains how the integration of data mining and machine learning can enable the modeling of conversation context, proximity sensing, and geospatial location throughout large communities of mobile users

  6. Radiation effects in optoelectronic devices

    International Nuclear Information System (INIS)

    A summary is given of studies on radiation effects in light-emitting diodes, laser diodes, detectors, optical isolators and optical fibers. It is shown that the study of radiation damage in these devices can provide valuable information concerning the nature of the devices themselves, as well as methods of hardening these devices for applications in radiation environments

  7. Modeling of graphene nanoribbon devices.

    Science.gov (United States)

    Guo, Jing

    2012-09-21

    Recent advances in graphene nanoribbon (GNR) electronic devices provide a concrete context for developing simulation methods, comparing theories to experiments, and using simulations to explore device physics. We present a review on modeling of graphene nanoribbon devices, with an emphasis on electronic and magnetoresistive devices. Device modeling is reviewed in a synergistic perspective with GNR material properties, device characteristics, and circuit requirements. Similarity with and difference to carbon nanotube devices are discussed. Device modeling and simulation results are compared to experimental data, which underlines the importance of theory-experiment collaborations in this field. Importance of the GNR edges, which have a negative impact on the carrier mobility due to edge roughness but offer new possibilities of spintronic devices and edge doping, is emphasized. Advanced device modeling of GNRs needs to have the capability to describe GNR device physics, including three-dimensional electrostatics, quantum and atomistic scale effects, elastic and inelastic scattering processes, electron-electron interaction, edge chemistry, magnetic field modulation, and spintronic and thermoelectric device phenomena. PMID:22875475

  8. Mechanical device for tissue regeneration

    NARCIS (Netherlands)

    Herder, J.L.; Maij, E.

    2010-01-01

    The invention relates to a mechanical device for tissue- regeneration inside a patient, comprising means (2, 3) to place a scaffold for the tissue under mechanical stress. Said means comprise a first device-part (2) and a second device-part (3) which parts are arranged to be movable with respect to

  9. Superconducting quantum-interference devices

    Science.gov (United States)

    Peters, P. N.; Holdeman, L. B.

    1975-01-01

    Published document discusses devices which are based on weak-link Josephson elements that join superconductors. Links can take numerous forms, and circuitry utilizing links can perform many varied functions with unprecedented sensitivity. Theoretical review of Josephson's junctions include tunneling junctions, point contact devices, microbridges, and proximity-effect devices.

  10. Webshop Optimization for Mobile Devices

    OpenAIRE

    Mei, Long

    2009-01-01

    This thesis deals with the programming technology which can be used to optimize the webshop design for mobile devices. The purpose of this thesis is to demonstrate several possible solutions when doing implementation of webshop applications for mobile devices. web application developers and companies who wants to optimize their products for mobile devices could also benefit from this study.

  11. Fundamentals of power semiconductor devices

    CERN Document Server

    Baliga, BJayant

    2010-01-01

    Offers an in-depth treatment of the physics of operation of power semiconductor devices that are commonly used by the power electronics industry. This book shows analytical models for explaining the operation of various power semiconductor devices. It is suitable for practicing engineers in the power semiconductor device community.

  12. Modeling of graphene nanoribbon devices

    Science.gov (United States)

    Guo, Jing

    2012-08-01

    Recent advances in graphene nanoribbon (GNR) electronic devices provide a concrete context for developing simulation methods, comparing theories to experiments, and using simulations to explore device physics. We present a review on modeling of graphene nanoribbon devices, with an emphasis on electronic and magnetoresistive devices. Device modeling is reviewed in a synergistic perspective with GNR material properties, device characteristics, and circuit requirements. Similarity with and difference to carbon nanotube devices are discussed. Device modeling and simulation results are compared to experimental data, which underlines the importance of theory-experiment collaborations in this field. Importance of the GNR edges, which have a negative impact on the carrier mobility due to edge roughness but offer new possibilities of spintronic devices and edge doping, is emphasized. Advanced device modeling of GNRs needs to have the capability to describe GNR device physics, including three-dimensional electrostatics, quantum and atomistic scale effects, elastic and inelastic scattering processes, electron-electron interaction, edge chemistry, magnetic field modulation, and spintronic and thermoelectric device phenomena.

  13. A microfluidic device with pillars

    DEFF Research Database (Denmark)

    2014-01-01

    The invention provides a microfluidic device for mixing liquid reagents, the device comprises, a chip forming at least one reaction chamber between a bottom and a top and extending between an inlet and an outlet. To enable manufacturing from less rigid materials, the device comprises pillars...

  14. Graphene device and method of using graphene device

    Science.gov (United States)

    Bouchiat, Vincent; Girit, Caglar; Kessler, Brian; Zettl, Alexander K.

    2015-08-11

    An embodiment of a graphene device includes a layered structure, first and second electrodes, and a dopant island. The layered structure includes a conductive layer, an insulating layer, and a graphene layer. The electrodes are coupled to the graphene layer. The dopant island is coupled to an exposed surface of the graphene layer between the electrodes. An embodiment of a method of using a graphene device includes providing the graphene device. A voltage is applied to the conductive layer of the graphene device. Another embodiment of a method of using a graphene device includes providing the graphene device without the dopant island. A dopant island is placed on an exposed surface of the graphene layer between the electrodes. A voltage is applied to the conductive layer of the graphene device. A response of the dopant island to the voltage is observed.

  15. Heterostructure terahertz devices.

    Science.gov (United States)

    Ryzhii, Victor

    2008-08-19

    The terahertz (THz) range of frequencies is borderline between microwave electronics and photonics. It corresponds to the frequency bands of molecular and lattice vibrations in gases, fluids, and solids. The importance of the THz range is in part due to numerous potential and emerging applications which include imaging and characterization, detection of hazardous substances, environmental monitoring, radio astronomy, covert inter-satellite communications, as well as biological and medical applications. During the last decades marked progress has been achieved in the development, fabrication, and practical implementation of THz devices and systems. This is primarily owing to the utilization of gaseous and free electron lasers and frequency converters using nonlinear optical phenomena as sources of THz radiation. However, such devices and hence the systems based on them are fairly cumbersome. This continuously stimulates an extensive search for new compact and efficient THz sources based on semiconductor heterostructures. Despite tremendous efforts lasting several decades, the so-called THz gap unbridged by semiconductor heterostructure electron and optoelectron devices still exists providing appropriate levels of power of the generated THz radiation. The invention and realization of quantum cascade lasers made of multiple quantum-well heterostructures already resulted in the partial solution of the problem in question, namely, in the successful coverage of the high-frequency portion of the THz gap (2-3 THz and higher). Further advancement to lower frequencies meets, perhaps, fundamental difficulties. All this necessitates further extensive theoretical and experimental studies of more or less traditional and novel semiconductor heterostructures as a basis for sources of THz radiation. This special issue includes 11 excellent original papers submitted by several research teams representing 14 institutions in Europe, America, and Asia. Several device concepts which

  16. Carbon based prosthetic devices

    Energy Technology Data Exchange (ETDEWEB)

    Devlin, D.J.; Carroll, D.W.; Barbero, R.S.; Archuleta, T. [Los Alamos National Lab., NM (US); Klawitter, J.J.; Ogilvie, W.; Strzepa, P. [Ascension Orthopedics (US); Cook, S.D. [Tulane Univ., New Orleans, LA (US). School of Medicine

    1998-12-31

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The project objective was to evaluate the use of carbon/carbon-fiber-reinforced composites for use in endoprosthetic devices. The application of these materials for the metacarpophalangeal (MP) joints of the hand was investigated. Issues concerning mechanical properties, bone fixation, biocompatibility, and wear are discussed. A system consisting of fiber reinforced materials with a pyrolytic carbon matrix and diamond-like, carbon-coated wear surfaces was developed. Processes were developed for the chemical vapor infiltration (CVI) of pyrolytic carbon into porous fiber preforms with the ability to tailor the outer porosity of the device to provide a surface for bone in-growth. A method for coating diamond-like carbon (DLC) on the articulating surface by plasma-assisted chemical vapor deposition (CVD) was developed. Preliminary results on mechanical properties of the composite system are discussed and initial biocompatibility studies were performed.

  17. Carbon for sensing devices

    CERN Document Server

    Tagliaferro, Alberto

    2015-01-01

    This book reveals why carbon is playing such an increasingly prominent role as a sensing material. The various steps that transform a raw material in a sensing device are thoroughly presented and critically discussed.  The authors deal with all aspects of carbon-based sensors, starting from the various hybridization and allotropes of carbon, with specific focus on micro and nanosized carbons (e.g., carbon nanotubes, graphene) and their growth processes. The discussion then moves to the role of functionalization and the different routes to achieve it. Finally, a number of sensing applications in various fields are presented, highlighting the connection with the basic properties of the various carbon allotropes.  Readers will benefit from this book’s bottom-up approach, which starts from the local bonding in carbon solids and ends with sensing applications, linking the local hybridization of carbon atoms and its modification by functionalization to specific device performance. This book is a must-have in th...

  18. Next generation toroidal devices

    International Nuclear Information System (INIS)

    A general survey of the possible approach for the next generation toroidal devices was made. Either surprisingly or obviously (depending on one's view), the technical constraints along with the scientific considerations lead to a fairly limited set of systems for the most favorable approach for the next generation devices. Specifically if the magnetic field strength of 5 T or above is to be created by superconducting coils, it imposes minimum in the aspect ratio for the tokamak which is slightly higher than contemplated now for ITER design. The similar technical constraints make the minimum linear size of a stellarator large. Scientifically, it is indicated that a tokamak of 1.5 times in the linear dimension should be able to produce economically, especially if a hybrid reactor is allowed. For the next stellarator, it is strongly suggested that some kind of helical axis is necessary both for the (almost) absolute confinement of high energy particles and high stability and equilibrium beta limits. The author still favors a heliac most. Although it may not have been clearly stated in the main text, the stability afforded by the shearless layer may be exploited fully in a stellarator. (author)

  19. Control rod blocking device

    International Nuclear Information System (INIS)

    Purpose: To increase the degree of freedom for the reactor operation by control rod blocking by monitoring the critical power ratio (CPR) with real time. Constitution: There has been a problem that the withdrawal of control rods may occasionally be inhibited with all the margin in view of CPR. The present invention dissolves this problem. That is, the control rod withdrawal device periodically calculates CPR, and calculated CPR upon generation of a control rod withdrawing signal by conpensating the result of calculation with a LPRM signal and a reactor core flow rate signal. The CPR at real time is compared with a predetermined setting value to output a control rod withdrawing inhibition signal depending on the result of the comparison. In the device as described above, since CPR is monitored at real time, the control rod can be withdrawn without causing fuel damages, as well as the inhibition of withdrawal irrespective of the presence of margin in view of CPR can be avoided. Accordingly, degree of freedom in the reactor operation can be increased. (Kamimura, M.)

  20. Reactor power measuring device

    International Nuclear Information System (INIS)

    The present invention provides a self-powered long detector having a sensitivity over the entire length of a reactor core as an entire control rod withdrawal range of a BWR type reactor, and a reactor power measuring device using a gamma ray thermometer which scarcely causes sensitivity degradation. That is, a hollow protection pipe is disposed passing through the reactor core from the outside of a reactor pressure vessel. The self-powered long detectors and the gamma ray thermometers are inserted and installed in the protection pipe. An average reactor power in an axial direction of the reactor relative to a certain position in the horizontal cross section of the reactor core is determined based on the power of the self-powered long detector over the entire length of the reactor core. Since the response of the self-powered detector relative to a local power change is rapid, the output is used as an input signal to a safety protection device of the reactor core. Further, a gamma ray thermometer secured in the reactor and having scarce sensitivity degradation is used instead of an incore travelling neutron monitor used for relative calibration of an existent neutron monitor secured in the reactor. (I.S.)

  1. Power distribution measuring device

    International Nuclear Information System (INIS)

    The present invention concerns a device for measuring power distribution of neutrons in a nuclear reactor. That is, a gamma thermometer used so far has drawbacks of slow time response and low sensitivity although it is not always necessary to use a movable incore detector for calibration. However, the device of the present invention compensates the drawback by incorporating a gamma thermometer and an another incore detector of a different type in an identical detector assembly. The gamma thermometer is calibrated by an electric heater. With such a constitution, the sensitivity calibration of the detector of different type incorporated in the identical detector assembly can be conducted without relying on a movable detector when the reactor is stable. Further, if the detector of the different type having rapid response, such as a fission ionization chamber or a self-powered type detector is used as a detector, a reactor core power distribution monitoring system of rapid time response can be attained. (I.S.)

  2. Stretchable and foldable electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, John A; Huang, Yonggang; Ko, Heung Cho; Stoykovich, Mark; Choi, Won Mook; Song, Jizhou; Ahn, Jong Hyun; Kim, Dae Hyeong

    2013-10-08

    Disclosed herein are stretchable, foldable and optionally printable, processes for making devices and devices such as semiconductors, electronic circuits and components thereof that are capable of providing good performance when stretched, compressed, flexed or otherwise deformed. Strain isolation layers provide good strain isolation to functional device layers. Multilayer devices are constructed to position a neutral mechanical surface coincident or proximate to a functional layer having a material that is susceptible to strain-induced failure. Neutral mechanical surfaces are positioned by one or more layers having a property that is spatially inhomogeneous, such as by patterning any of the layers of the multilayer device.

  3. Stretchable and foldable electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, John A; Huang, Yonggang; Ko, Heung Cho; Stoykovich, Mark; Choi, Won Mook; Song, Jizhou; Ahn, Jong Hyun; Kim, Dae Hyeong

    2014-12-09

    Disclosed herein are stretchable, foldable and optionally printable, processes for making devices and devices such as semiconductors, electronic circuits and components thereof that are capable of providing good performance when stretched, compressed, flexed or otherwise deformed. Strain isolation layers provide good strain isolation to functional device layers. Multilayer devices are constructed to position a neutral mechanical surface coincident or proximate to a functional layer having a material that is susceptible to strain-induced failure. Neutral mechanical surfaces are positioned by one or more layers having a property that is spatially inhomogeneous, such as by patterning any of the layers of the multilayer device.

  4. Human Factors and Medical Devices

    International Nuclear Information System (INIS)

    Medical device hardware- and software-driven user interfaces should be designed to minimize the likelihood of use-related errors and their consequences. The role of design-induced errors in medical device incidents is attracting widespread attention. The U.S. Food and Drug Administration (FDA) is fully cognizant that human factors engineering is critical to the design of safe medical devices, and user interface design is receiving substantial attention by the agency. Companies are paying more attention to the impact of device design, including user instructions, upon the performance of those health professionals and lay users who operate medical devices. Concurrently, the FDA is monitoring human factors issues in its site inspections, premarket device approvals, and postmarket incident evaluations. Overall, the outlook for improved designs and safer device operation is bright

  5. Cybersecurity for Connected Diabetes Devices.

    Science.gov (United States)

    Klonoff, David C

    2015-09-01

    Diabetes devices are increasingly connected wirelessly to each other and to data-displaying reader devices. Threats to the accurate flow of information and commands may compromise the function of these devices and put their users at risk of health complications. Sound cybersecurity of connected diabetes devices is necessary to maintain confidentiality, integrity, and availability of the data and commands. Diabetes devices can be hacked by unauthorized agents and also by patients themselves to extract data that are not automatically provided by product software. Unauthorized access to connected diabetes devices has been simulated and could happen in reality. A cybersecurity standard designed specifically for connected diabetes devices will improve the safety of these products and increase confidence of users that the products will be secure. PMID:25883162

  6. Firewood preparation devices in 1994

    International Nuclear Information System (INIS)

    A review of the market situation regarding firewood preparation devices is presented. The information was collected from the answers to a mail questionnaire. The review is assumed to include all the leading manufacturers and importers. Firewood production devices were available from 26 manufacturers. The range of models amounted to over 70. These may be divided into three categories: 1. cutting devices: the most common solution being a cross-cutting circular saw. There were only a few of these on sale as it is quite easy to include a splitting device on the same frame. 2. Splitting devices: e.g. screw splitter and hydraulically powered splitter. About 20 models are available on the markets. Cross cutting and splitting devices: these are the most popular devices. A cross-cutting circular saw with screw or hydraulic splitter is the most common type. There are about 50 models available on the markets. Cross-cutting and splitting devices are often equipped with conveyor for transferring the split wood e.g. into a trailer. Chopping devices are delivered as tractor powered devices, as electric motor powered devices or as combustion engine powered devices. Some of them are equipped with a time saving feeding device enabling the next stem to be lifted into position while the previous one is being chopped. The Finnish Work Efficiency Institute's studies show that when cross-cutting and splitting of stems into pieces of 35-50 cm in length, productivity for one operator varies in between 0.8 - 3.2 m3/h, depending on the device and work method used. (6 refs., 1 fig., 2 tabs.)

  7. Electronic control devices

    International Nuclear Information System (INIS)

    The subject of these lectures is the translation of information from particle detectors to computers. Large solid angle general purpose detectors at the intersection regions of high energy e+e- storage rings and pp and pp storage rings are discussed. Three choices for data acquisition are reviewed: use CAMAC (Computer Aided Measurement and Control), start from scratch and design a system, or wait for the final version of the proposed FASTBUS to be developed. The do-it-yourself procedure includes designs of drift chamber discriminator, time to amplitude converter, and data card block diagram. Trigger systems, the fast decision making systems judging an event interesting enough for a read-out cycle to be initiated, are discussed. Finally, a FASTBUS system layout, with its goals of minimum bus speed, general system topologies, and support multiple smart devices is given

  8. Bring Your Own Device

    OpenAIRE

    Muñoz, Rodrigo; Adami, Fovad

    2012-01-01

    Detta examensarbete har genomförts i samarbete med Sourcecom Svenska AB. Sourcecom Svenska AB arbetar med kommunikationslösningar inom IT-kommunikation, IT-säkerhet och telefoni. Examensarbetet går ut på att undersöka konceptet Bring Your Own Device (BYOD) och föreslå olika lösningar beroende på företagets informationssäkerhetskrav. För att förstå konceptet BYOD behövs först en inblick i hur ett policybaserat system fungerar. Rapporten undersöker och förklarar tre olika Network Access Control...

  9. Monitored separation device

    Science.gov (United States)

    Jackson, George William (Inventor); Willson, Richard Coale (Inventor); Fox, George Edward (Inventor)

    2011-01-01

    A device for separating and purifying useful quantities of particles comprises: a. an anolyte reservoir connected to an anode, the anolyte reservoir containing an electrophoresis buffer; b. a catholyte reservoir connected to a cathode, the catholyte reservoir also containing the electrophoresis buffer; c. a power supply connected to the anode and to the cathode; d. a column having a first end inserted into the anolyte reservoir, a second end inserted into the catholyte reservoir, and containing a separation medium; e. a light source; f. a first optical fiber having a first fiber end inserted into the separation medium, and having a second fiber end connected to the light source; g. a photo detector; h. a second optical fiber having a third fiber end inserted into the separation medium, and having a fourth fiber end connected to the photo detector; and i. an ion-exchange membrane in the anolyte reservoir.

  10. Nuclear reactor inspection device

    International Nuclear Information System (INIS)

    A typical embodiment of the invention combines a novel cellular end fitting for a nuclear reactor fuel assembly with a new design for a fuel rod end cap and a radiation sensing device probe to provide a means for swiftly and accurately distinguishing sound fuel rods from those rods that have developed leaks. For example, a somewhat thinner than usual fuel rod end cap is accessible through the open cellular structure of the end fitting to permit a hollow metal probe to contact the fuel rod end cap. This direct contact excludes most of the water, metal and other shielding materials from the volume between the interior of the fuel rod and the radiation detector, thereby improving the quality of the fuel rod examination. A bridge and trolley structure for accurately positioning the probe also is described

  11. Nuclear fusion device

    International Nuclear Information System (INIS)

    Grooves are formed on the wall surface disposed at the inner side of a vacuum vessel for confining plasmas, to thereby divide the flow channel of induced eddy current. During unsteady state of the plasmas, the flow channel of the eddy current induced on the wall surface is divided into a great number of small loops to inhibit the spacial extension of the induced eddy current, and the value of the induced eddy current is decreased. Therefore, electromagnetic forces formed on the wall surface due to interaction with steady magnetic fields are decreased to reduce the moment of the force exerted on the wall surface. The integrity and the reliability in view of the structure of the thermonuclear device can be improved. (N.H.)

  12. Plant control device

    International Nuclear Information System (INIS)

    A plant control device comprises an intellectual instrumentation group for measuring a predetermined process amount, an intellectual equipment group operating in accordance with a self-countermeasure, a system information space for outputting system information, a system level monitoring and diagnosing information generalization section for outputting system information, a system level maintenance information generalization section for outputting information concerning maintenance, a plant level information space and a plant level information generalization section. Each of them determines a state of the plant autonomously, and when abnormality is detected, each of the intellectual instrumentation, equipments and systems exchange information with each other, to conduct required operations including operations of intellectual robots, as required. Appropriate countermeasures for gauges, equipments and systems can be conducted autonomously at a place where operators can not access to improve reliability of complicate operations in the working site, as well as improve plant safety and reliability. (N.H.)

  13. Ceramics for fusion devices

    International Nuclear Information System (INIS)

    Ceramics are required for a number of applications in fusion devices, among the most critical of which are magnetic coil insulators, windows for RF heating systems, and structural uses. Radiation effects dominate consideration of candidate materials, although good pre-irradiation properties are a requisite. Materials and components can be optimized by careful control of chemical and microstructural content, and application of brittle material design and testing techniques. Future directions for research and development should include further extension of the data base in the areas of electrical, structural, and thermal properties; establishment of a fission neutron/fusion neutron correlation including transmutation gas effects; and development of new materials tailored to meet the specific needs of fusion reactors

  14. Laser beam steering device

    Science.gov (United States)

    Motamedi, M. E.; Andrews, A. P.; Gunning, W. J.

    1993-01-01

    Agile beam steering is a critical requirement for airborne and space based LIDAR and optical communication systems. Design and test results are presented for a compact beam steering device with low inertia which functions by dithering two complementary (positive and negative) binary optic microlens arrays relative to each other in directions orthogonal to the direction of light propagation. The miniaturized system has been demonstrated at scan frequencies as high as 300 Hz, generating a 13 x 13 spot array with a total field of view of 2.4 degrees. The design is readily extendable to a 9.5 degree field of view and a 52 x 52 scan pattern. The system is compact - less than 2 in. on a side. Further size reductions are anticipated.

  15. Light emitting ceramic device

    Science.gov (United States)

    Valentine, Paul; Edwards, Doreen D.; Walker, Jr., William John; Slack, Lyle H.; Brown, Wayne Douglas; Osborne, Cathy; Norton, Michael; Begley, Richard

    2010-05-18

    A light-emitting ceramic based panel, hereafter termed "electroceramescent" panel, is herein claimed. The electroceramescent panel is formed on a substrate providing mechanical support as well as serving as the base electrode for the device. One or more semiconductive ceramic layers directly overlay the substrate, and electrical conductivity and ionic diffusion are controlled. Light emitting regions overlay the semiconductive ceramic layers, and said regions consist sequentially of a layer of a ceramic insulation layer and an electroluminescent layer, comprised of doped phosphors or the equivalent. One or more conductive top electrode layers having optically transmissive areas overlay the light emitting regions, and a multi-layered top barrier cover comprising one or more optically transmissive non-combustible insulation layers overlay said top electrode regions.

  16. Surface Acoustic Wave Devices

    DEFF Research Database (Denmark)

    Dühring, Maria Bayard

    The work of this project is concerned with the simulation of surface acoustic waves (SAW) and topology optimization of SAW devices. SAWs are elastic vibrations that propagate along a material surface and are extensively used in electromechanical filters and resonators in telecommunication. A new...... application is modulation of optical waves in waveguides. This presentation elaborates on how a SAW is generated by interdigital transducers using a 2D model of a piezoelectric, inhomogeneous material implemented in the high-level programming language Comsol Multiphysics. The SAW is send through a model of a...... output waveguide and the MZI can thus be used as an optical switch. It is explained how the mechanical model of the SAW is coupled to a model of the optical waves such that the change in effective refractive index introduced in the MZI arms by the SAW can be calculated. Results of a parameter study of...

  17. False color viewing device

    International Nuclear Information System (INIS)

    A viewing device for observing objects in near-infrared false-color comprising a pair of goggles with one or more filters in the apertures, and pads that engage the face for blocking stray light from the sides so that all light reaching the user's eyes come through the filters. The filters attenuate most visible light and pass near-infrared (having wavelengths longer than approximately 700 nm) and a small amount of blue-green and blue-violet (having wavelengths in the 500 to 520 nm and shorter than 435 nm, respectively). The goggles are useful for looking at vegetation to identify different species and for determining the health of the vegetation, and to detect some forms of camouflage. 7 figs

  18. Millimeter wave nonreciprocal devices

    Science.gov (United States)

    Morgenthaler, F. R.

    1983-01-01

    The Microwave and Quantum Magnetics Group within the MIT Department of Electrical Engineering and Computer Science and the Research Laboratory of Electronics proposed a three year research program aimed at developing coherent magnetic wave signal-processing techniques for microwave energy which may form either the primary signal or else the intermediate frequency (IF) modulation of millimeter wavelength signals-especially at frequencies in the 50-94 GHz. range. Emphasis has been placed upon developing advanced types of signal processors that make use of quasi-optical propagation of electromagnetic and magnetostatic waves propagating in high quality single crystal ferrite thin films. A strong theoretical effort is required in order to establish valid models useful for predicting device performance. We emphasized new filter and circulator designs that employ combinations of the Faraday effect, field displacement nonreciprocity and magnetostatic resonance and periodic structures.

  19. Optically Reconfigurable Photonic Devices

    CERN Document Server

    Wang, Qian; Gholipour, Behrad; Wang, Chih-Ming; Yuan, Guanghui; Teng, Jinghua; Zheludev, Nikolay I

    2015-01-01

    Optoelectronic components with adjustable parameters, from variable-focal-length lenses to spectral filters that can change functionality upon stimulation, have enormous technological importance. Tuning of such components is conventionally achieved by either micro- or nano-mechanical actuation of their consitutive parts, stretching or application of thermal stimuli. Here we report a new dielectric metasurface platform for reconfigurable optical components that are created with light in a non-volatile and reversible fashion. Such components are written, erased and re-written as two-dimensional binary or grey-scale patterns into a nanoscale film of phase change material by inducing a refractive-index-changing phase-transition with tailored trains of femtosecond pulses. We combine germanium-antimony-tellurium-based films optimized for high-optical-contrast ovonic switching with a sub-wavelength-resolution optical writing process to demonstrate technologically relevant devices: visible-range reconfigurable bi-chr...

  20. Semiconductor device. Handotai sochi

    Energy Technology Data Exchange (ETDEWEB)

    Ebe, K.

    1993-10-15

    The wavelength area of the solar cell ranges widely from 0.3[mu]m short wavelength light to 2.4[mu]m long wavelength light, and semiconductor devices are desired to be developed which can absorb those wide range wavelength lights effectively for photoelectrical transfer. This invention is concerned with provision of a wide energy gap superlattice layer, which can absorb short wave light energy of the sunlight, and a narrow energy gap superlattice layer which can absorb long wavelength light energy of the sunlight, by stacking or by interposing the substrate. The energy gap of the formed superlattice layer is varied by gradual or continuous changing of the thickness of the barrier layer and the well layer of the narrow energy gap superlattice layer. As a result, high efficient solar cell is structured which can efficiently absorb the light of the sunlight ranging from short wavelength to long wavelength. 6 figs., 2 tabs.

  1. Reactor core monitoring device

    International Nuclear Information System (INIS)

    The device of the present invention reliably and conveniently detects an event of rapid increase of a coolant void coefficient at a portion of a channel by flow channel clogging event in a PWR-type reactor. Namely, upon flow channel clogging event, the coolant void coefficient is increased, an effective density is lowered, and a coolant shielding effect is lowered. Therefore, fast neutron fluxes at the periphery of a pressure tube are increased. The increase of the fast neutron fluxes is detected by a fast neutron flux detector disposed in a guide tube of an existent neutron flux detector. Based on the result, increase of coolant void coefficient can be detected. When an average void coefficient reaches from 30% to 100%, for example, the fast neutron fluxes are increased by about twice at a neutron permeation distance of coolants of about 10cm, thereby enabling to perform effective detection. (I.S.)

  2. Liquid wastes processing device

    International Nuclear Information System (INIS)

    Purpose: To enable safety and easy evaporation of liquid components in contaminated radioactive liquid wastes, as well as to recover the cleaned-up vapors by way of distillation into liquid components. Constitution: After supplying neutralized radioactive liquid wastes into an evaporator, a vertical moving rack is adjusted so as to suck the contaminated airs in a glove box. The liquid wastes are evaporated by a heater and the vapors are cleaned up in an inclined filter element. Further, the cleaned up vapors are formed into liquid in a water cooled cooling cylinder and then introduced to a gas phase separation and liquid collection device. While on the other hand, gases are sent from a gas outlet through a vent pipe to a suction pump and discharged therefrom into a simple glove box. (Horiuchi, T.)

  3. Analytic device including nanostructures

    KAUST Repository

    Di, Fabrizio, E.

    2015-07-02

    A device for detecting an analyte in a sample comprising: an array including a plurality of pixels, each pixel including a nanochain comprising: a first nanostructure, a second nanostructure, and a third nanostructure, wherein size of the first nanostructure is larger than that of the second nanostructure, and size of the second nanostructure is larger than that of the third nanostructure, and wherein the first nanostructure, the second nanostructure, and the third nanostructure are positioned on a substrate such that when the nanochain is excited by an energy, an optical field between the second nanostructure and the third nanostructure is stronger than an optical field between the first nanostructure and the second nanostructure, wherein the array is configured to receive a sample; and a detector arranged to collect spectral data from a plurality of pixels of the array.

  4. Position display device

    International Nuclear Information System (INIS)

    Object: To provide a device capable of easily and quickly reading mutual mounting relations of control bodies such as control rods mounted on a nuclear reactor and positions to which the control bodies are driven. Structure: A scanning circuit is provided to scan positions of controllably mounted control bodies such as control rods. Values detected by scanning the positions are converted into character signals according to the values and converted into preranked color signals. The character signals and color signals are stored in a memory circuit by synchronous signals in synchronism with the scanning in the scanning circuit. Outputs of the memory circuit are displayed by a display unit such as a color Braun tube in accordance with the synchronous signals to provide color representations according to positions to which control bodies are driven in the same positional relation as the mounting of the control bodies. (Kamimura, M.)

  5. Elongated toroid fusion device

    International Nuclear Information System (INIS)

    A device for achieving ignition of a plasma with ohmic heating is described comprising: means for defining a toroidal plasma chamber,a and confining gas therein, and means including electrically conductive coils for generating plasma within the chamber and for confining and shaping such plasma substantially into and filling a predetermined single region of the chamber without an axisymmetric internal separatix and ohmically heating the confined plasma to ignition. The predetermined region is toroidal with a major axis defining an axial direction parallel thereto and a transaxial direction perpendicular to the axis and having an axial cross section with an elongation, k, greater than 4, where k is the ratio of the maximum axial dimension of the cross section to the maximum transaxial dimension of the cross section

  6. QoE-Aware Device-to-Device Multimedia Communications

    Directory of Open Access Journals (Sweden)

    Liang ZHOU

    2015-08-01

    Full Text Available Multimedia services over mobile device-to-device (D2D networks has recently received considerable attention. In this scenario, each device is equipped with a cellular communication interface, as well as a D2D interface over a shared medium. In this work, we study the performance properties of the mobile D2D communications in the framework of user satisfaction, and develop a fully distributed QoE-aware multimedia communication scheme (QAMCS. Specifically, we translate the opportunistic multimedia communications issue into a stochastic optimization problem, which opens up a new degree of performance to exploit. Moreover, QAMCS is designed for a heterogeneous and dynamic environment, in which user demand, device mobility, and transmission fashion may vary across different devices and applications. Importantly, QAMCS is able to maximize the user satisfaction and only needs each device to implement its own scheme individually in the absence of a central controller.

  7. Radioactive gaseous waste processing device

    International Nuclear Information System (INIS)

    The present invention provides a device for continuously removing a moisture content in radioactive gaseous wastes (off gas) generated from a BWR type power generation plant. Namely, in a dehumidification device by utilizing hollow thread membranes of an off gas processing device, thermometers are disposed for measuring each of the temperature of off gases and the temperature of entrance of the off gas dehumidification device. A heater is disposed for heating the inside of the dehumidification device to a state corresponding to the temperature of off gases. A control device for controlling the heater by comparing the temperate of inflown gases and the temperature of the body of the dehumidification device. The inside of the dehumidifying device is heated to a temperature at or higher than the temperature of inflown off gases. Then, condensation of the moisture content contained in off gases in the dehumidification device can be prevented. In addition, if demister is disposed to an entrance nozzle portion of an off gas entrance chamber of the dehumidification device, mist of inflown off gases can be removed thereby enabling to improve steam permeation property of a hollow thread module. (I.S.)

  8. Hydrogen in portable devices

    International Nuclear Information System (INIS)

    Fuel cells were originally intended for use in power plants and vehicles. More recently, developers realised the possibility for building much smaller units and for lower prices per kilowatt than their larger relatives. This has led to a strong interest in developing small fuel cells. Small fuel cells could replace batteries in portable electronic equipment and internal combustion engines in portable generators. The upper limit for portable generators is about 5kW, mainly because of the weight of the fuel cell. The main applications for low-power fuel cells are mobile phones, personal digital assistants, laptop and notebook computers, cameras, medical equipment, military applications and other portable electronic devices. In comparison to batteries, fuel cells can supply much more power per unit volume or weight, though they have lower output voltages and are slower to respond to transients. Fuel cell types that are suitable for portable applications include: proton exchange membrane fuel cells (PEMFCs) using pure hydrogen, PEMFCs using hydrogen-rich gases from hydrocarbon or alcohol reforming, direct methanol fuel cells and, high-temperature fuel cells such as solid oxide fuel cells (SOFCs) and molten carbonate fuel cells (MCFCs) using hydrocarbons directly. Fuel cells for portable devices is becoming a niche, high-value market area which has good opportunities for a fast introduction of fuel cell technology and for the first consumer products in the electronic market can be expected within the coming year and is believed to grow rapidly thereafter. Danish industry is involved in the development of SOFC, PEMFC and DMFC fuel cells and the industry has in particular a strong position in system components and complete systems. An important area for Danish industry is system integration, where fuel cells and hydrogen technologies are implemented in electrical powered products. This is an area that is particular suited for small and medium sized enterprises and for

  9. Nanofabrication of Hybrid Optoelectronic Devices

    OpenAIRE

    Dibos, Alan

    2015-01-01

    The material requirements for optoelectronic devices can vary dramatically depending on the application. Often disparate material systems need to be combined to allow for full device functionality. At the nanometer scale, this can often be challenging because of the inherent chemical and structural incompatibilities of nanofabrication. This dissertation concerns the integration of seemingly dissimilar materials into hybrid optoelectronic devices for photovoltaic, plasmonic, and photonic appli...

  10. Optoelectronic devices toward monolithic integration

    Science.gov (United States)

    Ghergia, V.

    1992-12-01

    Starting from the present state of tl art of discrete devices up to the on going realization of monolithic semicorxtuctor integrated prototypes an overview ofoptoelectronic devices for telecom applications is given inchiding a short classification of the different kind of integrated devices. On the future perspective of IBCN distribution network some economica of hybrid and monolithic forms of integration are attempted. lnaflyashoitpresentationoftheactivitiesperformedintbefieldofmonolithic integration by EEC ESPR1T and RACE projects is reported. 1.

  11. Current devices of respiratory physiotherapy

    OpenAIRE

    Hristara-Papadopoulou, A; Tsanakas, J; Diomou, G; Papadopoulou, O.

    2008-01-01

    In recent years patients with respiratory diseases use various devices, which help the removal of mucus from the airways and the improvement of pulmonary function. The aim of the present study is to determine the effectiveness of the current devices of respiratory physiotherapy, as it comes from the review of literature. The current devices of physiotherapy for patients with respiratory diseases, are presented as an alternative therapy method or a supplemental therapy and they can motivate pa...

  12. Life cycle of mobile devices

    OpenAIRE

    T.V. Rohal; S.I. Naumenko; G.О Peresadko

    2011-01-01

    Article is devoted features of life cycle of mobile devices. The article highlighted a number of disadvantages associated with managing the life cycle of the product. Disadvantages include the orientation is not on the quality of mobile devices and their design, the obsolescence of digital products. The article drew attention to the need for process improvement life cycle management of mobile devices. For since this type of product is now the most popular among the population, consumers are i...

  13. Safe-haven locking device

    Science.gov (United States)

    Williams, J.V.

    1984-04-26

    Disclosed is a locking device for eliminating external control of a secured space formed by fixed and movable barriers. The locking device uses externally and internally controlled locksets and a movable strike, operable from the secured side of the movable barrier, to selectively engage either lockset. A disengagement device, for preventing forces from being applied to the lock bolts is also disclosed. In this manner, a secured space can be controlled from the secured side as a safe-haven. 4 figures.

  14. Notes on Conformal Invisibility Devices

    OpenAIRE

    Leonhardt, Ulf

    2006-01-01

    As a consequence of the wave nature of light, invisibility devices based on isotropic media cannot be perfect. The principal distortions of invisibility are due to reflections and time delays. Reflections can be made exponentially small for devices that are large in comparison with the wavelength of light. Time delays are unavoidable and will result in wave-front dislocations. This paper considers invisibility devices based on optical conformal mapping. The paper shows that the time delays do...

  15. Building Evacuation with Mobile Devices

    OpenAIRE

    Merkel, Sabrina

    2014-01-01

    The rapidly growing world population and increasingly dense settlements demand ever-larger and more complex buildings from today's engineers. In comparison to this technological progress, a building's equipment for emergency evacuation has been hardly developed further. This work presents a concept for a building evacuation system based on mobile devices. Furthermore, various algorithms for route planning with mobile devices and for indoor localization of mobile devices are addressed.

  16. Barriers to medical device innovation

    Directory of Open Access Journals (Sweden)

    Bergsl

    2014-06-01

    Full Text Available Jacob Bergsland, Ole Jakob Elle, Erik Fosse The Intervention Centre, Oslo University Hospital, Institute of Clinical Medicine, University of Oslo, Oslo, Norway Abstract: The US Food and Drug Administration (FDA has defined a medical device as a health care product that does not achieve it's purpose by chemical action or by being metabolized. This means that a vast number of products are considered medical devices. Such devices play an essential role in the practice of medicine. The FDA classifies medical devices in three classes, depending on the risk of the device. Since Class I and II devices have relatively simple requirements for getting to the market, this review will focus on “implantable devices”, which, in general, belong to Class III. The European Union and Canada use a slightly different classification system. While early generations of medical devices were introduced without much testing, either technical or clinical, the process of introducing a Class III medical device from concept to clinical practice has become strongly regulated and requires extensive technological and clinical testing. The modern era of implantable medical devices may be considered to have started in the 1920s with development of artificial hips. The implantable pacemaker was another milestone and pacemakers and cardioverters/defibrillators have since saved millions of lives and created commercial giants in the medical device industry. This review will include some examples of cardiovascular devices. Similar considerations apply to the total implantable device market, although clinical and technological applications obviously vary considerably. Keyword: implantable, FDA, regulation, CE-mark, innovation

  17. Fibre Optic Communication Key Devices

    CERN Document Server

    Grote, Norbert

    2012-01-01

    The book gives an in-depth description of the key devices of current and next generation fibre optic communication networks. In particular, the book covers devices such as semiconductor lasers, optical amplifiers, modulators, wavelength filters, and detectors but the relevant properties of optical fibres as well. The presentations include the physical principles underlying the various devices, the technologies used for the realization of the different devices, typical performance characteristics and limitations, and development trends towards more advanced components are also illustrated. Thus the scope of the book spans relevant principles, state-of-the-art implementations, the status of current research and expected future components.

  18. Mobile device security for dummies

    CERN Document Server

    Campagna, Rich; Krishnan, Ashwin

    2011-01-01

    The information you need to avoid security threats on corporate mobile devices Mobile devices have essentially replaced computers for corporate users who are on the go and there are millions of networks that have little to no security. This essential guide walks you through the steps for securing a network and building a bulletproof framework that will protect and support mobile devices in the enterprise. Featuring real-world case scenarios, this straightforward guide shares invaluable advice for protecting mobile devices from the loss of sensitive and confidential corporate informati

  19. Digital forensics for handheld devices

    CERN Document Server

    Doherty, Eamon P

    2012-01-01

    Approximately 80 percent of the world's population now owns a cell phone, which can hold evidence or contain logs about communications concerning a crime. Cameras, PDAs, and GPS devices can also contain information related to corporate policy infractions and crimes. Aimed to prepare investigators in the public and private sectors, Digital Forensics for Handheld Devices examines both the theoretical and practical aspects of investigating handheld digital devices. This book touches on all areas of mobile device forensics, including topics from the legal, technical, academic, and social aspects o

  20. Simulation of semiconductor devices

    CERN Document Server

    Oriato, D

    2001-01-01

    cathode, made using an AIGaAs heterostructure step. Simulations show the importance of the insertion of a thin highly-doped layer between the transit region and the electron launcher in order to improve device operation. Chapter 5 is an introduction to Ill-nitrides, in particular GaN and its alloy ln-GaN. We outline the discrepancy in the elastic and piezoelectric parameters found in the literature. Strain, dislocations and piezoelectricity are presented as the main features of a InGaN/GaN system. In chapter 6 an extensive simulation of the dependence of the optical band gap of a single InGaN quantum well on the piezoelectric and spontaneous polarization is reported. Quantum Confined Stark Effect and screening mechanisms are found to play a major role. The simulation of a novel InGaN/GaN double quantum well LED is presented. A wide well is used to capture electrons that tunnels in a narrow well where they recombine with holes. Resonant asymmetric tunneling of electron and holes is used to increase the efficie...

  1. Liquid waste processing device

    International Nuclear Information System (INIS)

    In a liquid waste processing device for processing living water wastes discharged from nuclear power plant facilities through a filtration vessel and a sampling vessel, a filtration layer disposed in the filtration vessel is divided into a plurality of layers along planes vertical to the direction of flow and the size of the filter material for each of the divided layers is made finer toward the downstream. Further, the thickness of the filtration material in each of the divided layers is also reduced toward the downstream. The filter material is packed such that the porosity in each of the divided layers is substantially identical. Further, the filtration material is packed in a mesh-like bag partitioned into a desired size and laid with no gaps to the planes vertical to the direction of the flow. Thus, liquid wastes such as living water wastes can be processed easily and simply so as to satisfy circumstantial criteria without giving undesired effects on the separation performance and life time and with easy replacement of filter. (T.M.)

  2. Reactor container spray device

    International Nuclear Information System (INIS)

    Purpose: To enable decrease in the heat and the concentration of radioactive iodine released from the reactor vessel into the reactor container in the spray device of BWR type reactors. Constitution: A plurality of water receiving trays are disposed below the spray nozzle in the dry well and communicated to a pressure suppression chamber by way of drain pipeways passing through a diaphragm floor. When the recycling system is ruptured and coolants in the reactor vessel and radioactive iodine in the reactor core are released into the dry well, spray water is discharged from the spray nozzle to eliminate the heat and the radioactive iodine in the dry well. In this case, the receiving trays collect the portions of spray water whose absorption power for the heat and radioactive iodine is nearly saturated and falls them into the pool water of the pressure suppression chamber. Consequently, other portions of the spray water that still possess absorption power can be jetted with no hindrance, to increase the efficiency for the removal of the heat and iodine of the spray droplets. (Horiuchi, T.)

  3. Radioactive iodine removing device

    International Nuclear Information System (INIS)

    In a radioactive iodine removing device of an off-gas processing step in a spent fuel reprocessing facility, spiral structures having an inclination of more than about 20deg is disposed at the inside of an iodine adsorbent packing portion, and dampers are disposed at a packing inlet and a discharging exit for iodine adsorbents respectively. After completion of discharge of the iodine adsorbents, a damper disposed in the midway of a adsorbent packing pipeline is opened for packing the iodine absorbents. The iodine adsorbents used have a spherical shape of 10 to 20 mesh (1 to 2mm), and the adsorbents are packed uniformly both radially and vertically to the packing portion upon injection of the adsorbents and, as a result, the packing portion can be made compact. Further, since the discharged iodine adsorbents can be contained in a vessel directly or in a different vessel having an excellent containing performance by taking the dimension of the vessel into consideration, it is possible to reduce the generation amount of wastes than that in a conventional case. (N.H.)

  4. ITER tokamak device

    Science.gov (United States)

    Doggett, J.; Salpietro, E.; Shatalov, G.

    1991-07-01

    The results of the Conceptual Design Activities for the International Thermonuclear Experimental Reactor (ITER) are summarized. These activities, carried out between April 1988 and December 1990, produced a consistent set of technical characteristics and preliminary plans for co-ordinated research and development support of ITER, a conceptual design, a description of design requirements and a preliminary construction schedule and cost estimate. After a description of the design basis, an overview is given of the tokamak device, its auxiliary systems, facility and maintenance. The interrelation and integration of the various subsystems that form the ITER tokamak concept are discussed. The 16 ITER equatorial port allocations, used for nuclear testing, diagnostics, fueling, maintenance, and heating and current drive, are given, as well as a layout of the reactor building. Finally, brief descriptions are given of the major ITER sub-systems, i.e., (1) magnet systems (toroidal and poloidal field coils and cryogenic systems), (2) containment structures (vacuum and cryostat vessels, machine gravity supports, attaching locks, passive loops and active coils), (3) first wall, (4) divertor plate (design and materials, performance and lifetime, a.o.), (5) blanket/shield system, (6) maintenance equipment, (7) current drive and heating, (8) fuel cycle system, and (9) diagnostics.

  5. Plant monitoring device

    International Nuclear Information System (INIS)

    The device of the present invention comprises a data collecting section for periodically collecting processed data sent from plant equipments, a top node induction and processing section for an important plant function model for inducing the plant function to be noted particularly by an operator from important plant function models by using process data and a window screen selection section for selecting a window screen to be displayed based on the result of the evaluation for each of function nodes based on the processing described above and determining the layout and automatically forming the display screen. It is constituted so that the kind and the layout of the window under display are checked if they are the same as those one cycle before or not and, if they are different, the screen is automatically switched to a new screen display. Then, operator's psychological burdens such as selection of information and judgement for the operation upon occurrence of plant abnormality and accident can be mitigated, to provide a safe operation circumstance having reinforced monitoring of the function of the whole plant can be provided. (N.H.)

  6. Radioactive gas solidifying device

    International Nuclear Information System (INIS)

    The device of the present invention, a sputtering electrode comprises a cylindrical electrode main body made of a transition metal, electrode caps each made of a transition metal and connected by welding to the upper and the lower portions of the main body and a plurality of annular grooves formed to the outer surface of the electrode main body. The electrode main body and the electrode cap are connected by welding at the portions of the annular grooves, and rare earth elements are filled in the annular grooves. Then, when operation is conducted for a long period of time, the thickness of the electrode is gradually reduced by sputtering. When the rare earth element in the annular grooves are completely eliminated by the reduction of the thickness, radioactive gases are no more injected into the accumulated metal layers of sputtered metal formed at the surface of the ion injection electrode, to reduce the processing efficiency. By detecting the reduction and interrupting the operation directly, the reduction of the wall thickness in the welded portion between the main body and the electrode cap is prevented. In this way, it is possible to prevent the leakage of cooling water therefrom and abnormal electric discharge caused thereby, to enable stable operation for a long period of time. (T.M.)

  7. Ultrasonic wave inspection device

    International Nuclear Information System (INIS)

    The device of the present invention inspects incore structural components by visualizing them by scanning an ultrasonic transducer in an opaque liquid metal sodium in a pressure vessel of an FBR type reactor. Namely, a piezoelectric vibrator for transmitting/receiving ultrasonic waves is formed into a protruded shape. A portion at the center of the protruded piezoelectric vibrator is coaxially separated. Upon transmitting ultrasonic waves, a large opening of the entire piezoelectric vibrator is used. A small opening at the center of the piezoelectric vibrator is used upon receiving ultrasonic waves. With such a constitution, an object to be inspected is visualized based on the waveform of the received ultrasonic wave signals defining the center of a curvature of the protruded piezoelectric vibrator as a position of transmitting ultrasonic waves and defining the center of the opening at the center of the piezoelectric vibrator as a position of receiving ultrasonic waves. As a result, the energy of the ultrasonic waves can be enhanced to improve sensitivity upon transmitting ultrasonic waves. Since the distance between an optional position of the receiving surface and the reflecting surface of the object is minimized upon receiving ultrasonic waves, there is no distortion in the waveforms of the received signals thereby enabling to obtain images at high accuracy. (I.S.)

  8. Emergency gas processing device

    International Nuclear Information System (INIS)

    The present invention provides an emergency gas processing device which discharged contaminated air in a reactor building to the outside. Namely, a suction port of an emergency gas processing pipeline is disposed in the inside of the reactor building. The exit of the pipeline is connected to an exhaustion pipe of the building. On the side of the inlet of the pipeline, there are disposed an inlet valve, an air dryer, a blower, a filter unit and an exit valve from the suction port to the downstream. A heater is disposed to the air dryer. A recycling pipeline equipped with an automatic closing valve for connecting the inlet side of the inlet valve and the inlet side of the exit valve is disposed. Then, the moisture in an emergency gas flown from the inlet valve is removed, heated by the heater, and the temperature of the emergency gas is elevated. Impurities are removed by the filter unit. The automatic closing valve of the recycling pipeline is opened and the blower and the heater are operated to keep the temperature and humidity in the filter unit to a predetermined value during stand-by time. Upon occurrence of an accident, the automatic closing valve is closed, and the aimed system operation is preformed. (I.S.)

  9. Reactor power measuring device

    International Nuclear Information System (INIS)

    The device of the present invention comprises a γ-thermometer disposed in a BWR type reactor, a first amplifier for amplifying the output thereof, a fission ionization chamber disposed in the reactor separately from the γ-thermometer, a second amplifier for amplifying the output thereof, a differential circuit for differentiating the output signal of the second amplifier and a first adding circuit for adding an output signal of the differential circuit and an output signal of the first amplifier. Alternatively, a γ-ray self-powered neutron detector may be disposed instead of the fission ionization chamber. A second adding circuit is also disposed for adding the output signals of plurality of differentiation circuits and inputting the result to the first adding circuit. A sensitivity controller is disposed upstream of the first adder for controlling the sensitivity of the fission ionization chamber. Then, even if time delay should be caused in the γ-thermometer, output signals with good time response characteristic can be obtained by using signals of LPRM or SPND, and currently changing output of the reactor can be measured accurately to provide an effect on the improvement of the safety and operation controllability of the reactor. (N.H.)

  10. Hot gas handling device and motorized vehicle comprising the device

    NARCIS (Netherlands)

    Klein Geltink, J.; Beukers, A.; Van Tooren, M.J.L.; Koussios, S.

    2012-01-01

    The invention relates to a device for handling hot exhaust gasses discharged from an internal combustion engine. The device comprises a housing (2), enclosing a space (3) for transporting the exhaust gasses. The housing (2) is provided with an entrance - opening (4) for the exhaust gasses discharged

  11. 77 FR 58576 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers...

    Science.gov (United States)

    2012-09-21

    ... COMMISSION Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers, and... importation of certain wireless communication devices, portable music and data processing devices, computers... after importation of certain wireless communication devices, portable music and data processing...

  12. 77 FR 51571 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers...

    Science.gov (United States)

    2012-08-24

    ... COMMISSION Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers, and.... International Trade Commission has received a complaint entitled Wireless Communication Devices, Portable Music... communication devices, portable music and data processing devices, computers, and components thereof....

  13. 21 CFR 882.5050 - Biofeedback device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Biofeedback device. 882.5050 Section 882.5050 Food... DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5050 Biofeedback device. (a) Identification. A biofeedback device is an instrument that provides a visual or auditory signal corresponding...

  14. Metal hydride actuation device

    International Nuclear Information System (INIS)

    A self-recocking actuation device is disclosed. One possible use for it is in conjunction with a pneumatic fire protection system. This invention employs the process known as occlusion to store large amounts of gas in a small volume. Metal hydrides in a chamber are used to store hydrogen in the disclosed preferred embodiment. Upon the application of heat-from a heat source like a resistance heater-the charged metal hydride releases its hydrogen (H2) in a chamber having only one exit opening which empties into a sealed bellows. This bellows contacts a piston located in another chamber wherein a biased resetting spring is provided to normally maintain the piston in contact with the bellows. As the pressure from the H2 gas builds up, it overcomes the biased spring to move it and the piston along with an associated pin or other actuator. If used to actuate a pneumatic fire protection system, the pin or actuator at the downward side of its stroke in turn, may puncture a shearable diaphragm or in some other way releases the contents of a container containing a second gas, like nitrogen (N2), which is then released from a second exit port in a different chamber to charge the fire protection system. Recocking of the piston begins as the heating of the metal hydride ceases. As cooling takes place the hydrogen is absorbed to reenter the hydride to decrease the gas pressure supplied. The piston's biased resetting spring then recocks the piston to its original position

  15. Plugging device for nuclear pipes

    International Nuclear Information System (INIS)

    The plugging device assembled near an access opening is used for plugging the primary pipes. This plugging device comprises a rim flexible joint put in mechanical pressure by the displacement of mechanical pieces. This joint has a central compartment pressurizable. This joint is fixed by a stirrup-piece and a shaft in support on the tube plate

  16. Polymer Thermoelectric Generators: Device Considerations

    Science.gov (United States)

    Yee, Shannon

    2014-03-01

    Recent control of the transport properties in polymers has encouraged the development of polymer thermoelectric (TE) devices. Polymer TEs are thought to be less expensive and more scalable than their inorganic counterparts. The cost of the raw material is less and polymer TEs can leverage the large areal manufacturing technique established by the plastics industry. Additionally, while the overall ZT of polymer TEs appears attractive, individual polymer properties have a very different scale than their inorganic counterparts (i.e., the thermal conductivity and electrical conductivity are approximately one and two orders of magnitude smaller, respectively). Furthermore, the majority of TE measurements on polymers have been limited to thin-films where traditional TE materials are measured in bulk. So why should it be expected that polymer TE devices resemble traditional TE devices? Given the uniqueness of polymers, different device architectures are proposed that can leverage the unique strengths of polymer films. It will be shown that by logically considering device requirements, new polymer TE devices have non-linear features that are more attractive than linear inorganic TE devices. This leads to very different device optimizations that favor polymer TEs.

  17. Insertion device vacuum system designs

    International Nuclear Information System (INIS)

    Synchrotron light source insertion device vacuum systems now in operation and systems proposed for the future are reviewed. An overview of insertion devices is given and four generic vacuum chamber designs, transition section design and pumping considerations are discussed. Examples of vacuum chamber systems are presented

  18. Semiconductor Switching Devices. .Future Trends

    Directory of Open Access Journals (Sweden)

    S. Ahmad

    1998-01-01

    Full Text Available A variety of semiconductor devices and circuits have been successfully developed usingconduction properties of electrons and holes in a number of elemental and compound semiconductors.Carriers confinement in a potential well, formed out of a thin layer of lower band gap materialsandwitched between two layers of a higher band gap material, has been extended from one to two andthree dimensions. Resultant of two-dimensional carrier sheet, quantum wire and quantum dot havingdiscrete energy levels arising out of quantisation are being presently explored for possible device applications. A number of devices have been fabricated using resonant tunneling across a thin potentialbarrier. This has opened up several newer possibilities of using such structures for various electronicand optoelectronic devices and circuits applications as tunneling is relatively faster than conductionprocess. While looking into the interband tunneling between two quantum dots, possibility of a singleelectron switching has also been examined carefully. The idea of a single electron switching isconceptually being extended from quantl,lm dots to molecules and atoms ultimately. Simulations basedon transmission of electrons through a chain of molecules and atoms have shown that tens of THz speed and functional device density 1012 devices/mm2 are possible with such schemes. Devices basedon atom relay transistor (ART will be ultimate in its performance of switching speed. A brief onpresent-day situation followed by future proposals of fast switching devices for informationelectronics has been discussed.

  19. Wound Healing Devices Brief Vignettes

    OpenAIRE

    Anderson, Caesar A.; Hare, Marc A.; Perdrizet, George A.

    2016-01-01

    Significance: The demand for wound care therapies is increasing. New wound care products and devices are marketed at a dizzying rate. Practitioners must make informed decisions about the use of medical devices for wound healing therapy. This paper provides updated evidence and recommendations based on a review of recent publications.

  20. A Device with Learning Capability.

    Science.gov (United States)

    Sotina, N. M.; Burlai, Yu. P.

    The invention involves a device with learning capacity which contains input, storage, arithmetic and output units. In order to increase the number of recognizable patterns, facilitate replacement of one pattern by another, and also increase the speed of the device, the memory unit for the input field is connected to memory units for storage of…

  1. Sample processing device and method

    DEFF Research Database (Denmark)

    2011-01-01

    A sample processing device is disclosed, which sample processing device comprises a first substrate and a second substrate, where the first substrate has a first surface comprising two area types, a first area type with a first contact angle with water and a second area type with a second contact...

  2. Speech Recognition on Mobile Devices

    DEFF Research Database (Denmark)

    Tan, Zheng-Hua; Lindberg, Børge

    2010-01-01

    The enthusiasm of deploying automatic speech recognition (ASR) on mobile devices is driven both by remarkable advances in ASR technology and by the demand for efficient user interfaces on such devices as mobile phones and personal digital assistants (PDAs). This chapter presents an overview of ASR...

  3. Satellite and acoustic tracking device

    KAUST Repository

    Berumen, Michael L.

    2014-02-20

    The present invention relates a method and device for tracking movements of marine animals or objects in large bodies of water and across significant distances. The method and device can track an acoustic transmitter attached to an animal or object beneath the ocean surface by employing an unmanned surface vessel equipped with a hydrophone array and GPS receiver.

  4. Personalized Adaptation to Device Characteristics

    NARCIS (Netherlands)

    Herder, E.; Dijk, van E.M.A.G.; de Bra, P.; Brusilovsky, P.; Conejo, R.

    2002-01-01

    Device characteristics, such as screen size and means of interaction, and the context in which a device is used, seriously affect the user’s mental representation of an information environment and its intended use. We hypothesize that user characteristics are valuable resources for determining which

  5. Electrical nanogap devices for biosensing

    Directory of Open Access Journals (Sweden)

    Xing Chen

    2010-11-01

    Full Text Available For detecting substances that are invisible to the human eye or nose, and particularly those biomolecules, the devices must have very small feature sizes, be compact and provide a sufficient level of sensitivity, often to a small number of biomolecules that are just a few nanometres in size. Electrical nanogap devices for biosensing have emerged as a powerful technique for detecting very small quantities of biomolecules. The most charming feature of the devices is to directly transduce events of biomolecules specific binding into useful electrical signals such as resistance/impedance, capacitance/dielectric, or field-effect. Nanogap devices in electrical biosensing have become a busy area of research which is continually expanding. A wealth of research is available discussing planar and vertical nanogap devices for biosensing. Planar nanogap devices including label-free, gold nanoparticle-labeled, nanoparticles-enhanced, nanogapped gold particle film, and carbon nanotube nanogap devices as well as vertical nanogap devices with two and three terminals for biosensing are carefully reviewed. The aim of this paper is to provide an updated overview of the work in this field. In each part, we discuss the principles of operation of electrical biosensing and consider major strategies for enhancing their performance and/or key challenges and opportunities in current stages, and in their further development.

  6. Selection of Air Terminal Device

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,......This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,...

  7. SAW-Modulated Image Device

    Science.gov (United States)

    Benz, H. F.

    1985-01-01

    Imaging device uses surface-acoustic-wave (SAW) charge transfer for image readout. Spatial resolution of image changed electronically by changing frequency of applied signal. Surface acoustic waves create traveling longitudinal electric fields. These fields create potential wells that carry along stored charges. Charges injected into wells by photoelectric conversion when light strikes device.

  8. Mixing in a Microfluid Device

    DEFF Research Database (Denmark)

    Hjorth, Poul G.; Deryabin, Mikhail

    Mixing of fluids in microchannels cannot rely on turbulence since the flow takes place at extremly low Reynolds numbers. Various active and passive devices have been developed to induce mixing in microfluid flow devices. We describe here a model of an active mixer where a transverse periodic flow...

  9. Nuclear technical or chemical device

    International Nuclear Information System (INIS)

    The handling element and the tool are provided in a complementary way with a marking and a sensor for detecting the marking. The sensor is connected to a switching device, which controls the remote control depending on travel and/or time. The sensor controls a positioning device, which causes the tool to engage with the handling element. (orig./HP)

  10. Content Sharing for Mobile Devices

    CERN Document Server

    Ball, Rudi

    2008-01-01

    The miniaturisation of computing devices has seen computing devices become increasingly pervasive in society. With this increased pervasiveness, the technologies of small computing devices have also improved. Mobile devices are now capable of capturing various forms of multimedia and able to communicate wirelessly using increasing numbers of communication techniques. The owners and creators of local content are motivated to share this content in ever increasing volume; the conclusion has been that social networks sites are seeing a revolution in the sharing of information between communities of people. As load on centralised systems increases, we present a novel decentralised peer-to-peer approach dubbed the Market Contact Protocol (MCP) to achieve cost effective, scalable and efficient content sharing using opportunistic networking (pocket switched networking), incentive, context-awareness, social contact and mobile devices. Within the report we describe how the MCP is simulated with a superimposed geographi...

  11. Pressurized waterproof case electronic device

    KAUST Repository

    Berumen, Michael L.

    2013-01-31

    A pressurized waterproof case for an electronic device is particularly adapted for fluid-tight containment and operation of a touch-screen electronic device or the like therein at some appreciable water depth. In one example, the case may be formed as an enclosure having an open top panel or face covered by a flexible, transparent membrane or the like for the operation of the touchscreen device within the case. A pressurizing system is provided for the case to pressurize the case and the electronic device therein to slightly greater than ambient in order to prevent the external water pressure from bearing against the transparent membrane and pressing it against the touch screen, thereby precluding operation of the touch screen device within the case. The pressurizing system may include a small gas cartridge or may be provided from an external source.

  12. Surgical tools and medical devices

    CERN Document Server

    Jackson, Mark

    2016-01-01

    This new edition presents information and knowledge on the field of biomedical devices and surgical tools. The authors look at the interactions between nanotechnology, nanomaterials, design, modeling, and tools for surgical and dental applications, as well as how nanostructured surfaces can be created for the purposes of improving cell adhesion between medical devices and the human body. Each original chapter is revised in this second edition and describes developments in coatings for heart valves, stents, hip and knee joints, cardiovascular devices, orthodontic applications, and regenerative materials such as bone substitutes. There are also 8 new chapters that address: Microvascular anastomoses Inhaler devices used for pulmonary delivery of medical aerosols Surface modification of interference screws Biomechanics of the mandible (a detailed case study) Safety and medical devices The synthesis of nanostructured material Delivery of anticancer molecules using carbon nanotubes Nano and micro coatings for medic...

  13. Optical device for straightness measurement

    Science.gov (United States)

    Vekteris, Vladas; Jurevicius, Mindaugas; Turla, Vytautas

    2015-11-01

    The present paper describes the research of the optical device for two-dimensional straightness measurement of technological machines. Mathematical study of an optical device, operating on the phase principle and measuring transversal displacements of machine parts in two directions ( X and Y) during their linear longitudinal motion in a machine (alongside the Z axis), is presented. How to estimate the range of travel along the Z axis is analytically shown. At this range, the measurer gives correct measurements of transverse displacement. The necessary distance from the objective focus to the image plane was defined mathematically. The sample results of measuring the displacement of the table of a technological machine by using the optical device are presented in the paper. This optical device for non-contact straightness measurement can be used for measurement straightness in turning, milling, drilling, grinding machines and other technological machines, also in geodesy and cartography, and for moving accuracy testing of mechatronic devices, robotics and others.

  14. Pyrotechnic devices and their applications

    Science.gov (United States)

    Himelblau, Harry

    2002-05-01

    Pyroshock is mechanical shock transmitted through structures from explosive devices, sometimes accompanied by structural impact. These devices are designed to cause the intentional separation of structures, or to cause the deployment of various mechanisms or subsystems required for mission operation. Separation devices usually fall into two categories: (a) line sources, such as linear shaped charges, and (b) point sources, such as explosive bolts, pin puller and pushers, and gas generators. The advantages of these devices are high reliability (especially when redundantly activated), low cost and weight, high activation speed, and low structural deformation a short distance from the source. The major limitation is pyroshock, a severe high-frequency transient capable of causing failure or malfunction to small nearby elements, especially electronic and optical components located close to the source. This pyroshock tutorial, which is intended to summarize recent improvements to the technology, is initiated with a review of explosive and companion devices.

  15. Device Applications of Nonlinear Dynamics

    CERN Document Server

    Baglio, Salvatore

    2006-01-01

    This edited book is devoted specifically to the applications of complex nonlinear dynamic phenomena to real systems and device applications. While in the past decades there has been significant progress in the theory of nonlinear phenomena under an assortment of system boundary conditions and preparations, there exist comparatively few devices that actually take this rich behavior into account. "Device Applications of Nonlinear Dynamics" applies and exploits this knowledge to make devices which operate more efficiently and cheaply, while affording the promise of much better performance. Given the current explosion of ideas in areas as diverse as molecular motors, nonlinear filtering theory, noise-enhanced propagation, stochastic resonance and networked systems, the time is right to integrate the progress of complex systems research into real devices.

  16. Turi device for radioactive source transport in the MUK device

    International Nuclear Information System (INIS)

    The TURI radioactive source transport device for on-line studies with a mass spectrometer in a proton beam is described. This device is a part of the multidetector MUK-device the aim of which is the measurement of the angular correlations and lifetimes observed in radioactive decay of short-lived nuclei (T1/2>0.1 s). The TURY system ensures the velocity of the radioactive target movement 1 cm per 0.25 s, and microcomputer control of experiment the accuracy of the tape stop is 0.15 mm

  17. Multilayer polymer light emitting devices

    Science.gov (United States)

    Barcikowski, Zachary; Thomas, Adam; Tzolov, Marian

    2013-03-01

    The interplay of device layers and their interfaces is a major area of study in Polymer Light Emitting Devices (PLEDs). Many factors such as the degradation, efficiency, and overall performance depend on how these layers interact with each other. A fundamental understanding of the interfaces of these layers can lend to better performing devices using a multitude of organic polymers deposited in conjunction with each other in several ways. We have studied basic PLED devices in which we vary the emissive layer used, along with final bake temperatures. Devices include a glass substrate with Indium Tin Oxide anode, Aluminum cathode, and Plexcore Hole Injection layer. The active polymer films were spin casted from solution of MEH-PPV and PFO. Single layer and dual layers of several polymers are studied by examining current-voltage characteristics, film densities, impedance measurements, light emission, and efficiency calculations. We have found that not only do dual layers positively alter the performance of the device in the majority of cases, but the solvents in which each layer is originally in when deposited affects the formation of the interface, thereby altering the device mechanisms.

  18. High voltage MOSFET devices and methods of making the devices

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran

    2015-12-15

    A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+ region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.

  19. Hot gas handling device and motorized vehicle comprising the device

    OpenAIRE

    Klein Geltink, J.; Beukers, A.; Van Tooren, M.J.L.; Koussios, S.

    2012-01-01

    The invention relates to a device for handling hot exhaust gasses discharged from an internal combustion engine. The device comprises a housing (2), enclosing a space (3) for transporting the exhaust gasses. The housing (2) is provided with an entrance - opening (4) for the exhaust gasses discharged from the engine and an exit-opening (5) for transporting the exhaust gasses away from the engine, and comprises a flexible thermal insulating layer, arranged for resisting the temperature of the e...

  20. Mobile device-to-device distributed computing using data sets

    OpenAIRE

    Remédios, Diogo; Teófilo, António; Paulino, Hervé; Lourenço, João

    2015-01-01

    The rapidly increasing computing power, available storage and communication capabilities of mobile devices makes it possible to start processing and storing data locally, rather than offloading it to remote servers; allowing scenarios of mobile clouds without infrastructure dependency. We can now aim at connecting neighboring mobile devices, creating a local mobile cloud that provides storage and computing services on local generated data. In this paper, we describe an early overview of a dis...

  1. Skin-inspired electronic devices

    Directory of Open Access Journals (Sweden)

    Alex Chortos

    2014-09-01

    Full Text Available Electronic devices that mimic the properties of skin have potential important applications in advanced robotics, prosthetics, and health monitoring technologies. Methods for measuring tactile and temperature signals have progressed rapidly due to innovations in materials and processing methods. Imparting skin-like stretchability to electronic devices can be accomplished by patterning traditional electronic materials or developing new materials that are intrinsically stretchable. The incorporation of sensing methods with transistors facilitates large-area sensor arrays. While sensor arrays have surpassed the properties of human skin in terms of sensitivity, time response, and device density, many opportunities remain for future development.

  2. Arrhythmia management after device removal.

    Science.gov (United States)

    Nishii, Nobuhiro

    2016-08-01

    Arrhythmic management is needed after removal of cardiac implantable electronic devices (CIEDs). Patients completely dependent on CIEDs need temporary device back-up until new CIEDs are implanted. Various methods are available for device back-up, and the appropriate management varies among patients. The duration from CIED removal to implantation of a new CIED also differs among patients. Temporary pacing is needed for patients with bradycardia, a wearable cardioverter defibrillator (WCD) or catheter ablation is needed for patients with tachyarrhythmia, and sequential pacing is needed for patients dependent on cardiac resynchronization therapy. The present review focuses on arrhythmic management after CIED removal. PMID:27588151

  3. A TOUCH-SENSITIVE DEVICE

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to an optical touch-sensitive device and a method of determining a position and determining a position change of an object contacting an optical touch sensitive device. In particular, the present invention relates to an optical touch pad and a method of determining a...... position and determining a position change of an object contacting an optical touch pad. A touch-sensitive device, according to the present invention may comprise a light source, a touch- sensitive waveguide, a detector array, and a first light redirecting member, wherein at least a part of the light...

  4. Spintronics technology and device development

    International Nuclear Information System (INIS)

    Spintronics is an emerging field of research that has made great advances in the last two decades. During this period, various new outstanding spintronics-related phenomena and devices using these phenomena have been proposed. In recent years, the period from the discovery of new spintronics-related materials and phenomena to the development and commercialization of devices using such materials and phenomena has markedly shortened. The importance of understanding the fundamental principles of spintronics has been increasing. In this review, I will first overview the features of spintronics technologies. Then, I will summarize the key technologies applied in the development of spintronic devices and describe their future prospects. (author)

  5. Streamline-based microfluidic device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Kasdan, Harvey (Inventor)

    2013-01-01

    The present invention provides a streamline-based device and a method for using the device for continuous separation of particles including cells in biological fluids. The device includes a main microchannel and an array of side microchannels disposed on a substrate. The main microchannel has a plurality of stagnation points with a predetermined geometric design, for example, each of the stagnation points has a predetermined distance from the upstream edge of each of the side microchannels. The particles are separated and collected in the side microchannels.

  6. 77 FR 6028 - Taxable Medical Devices

    Science.gov (United States)

    2012-02-07

    ..., the definition of ``taxable medical device'' under section 4191 limits taxable medical devices to... medical devices, such as medical device data systems, under long-term, multi-year contracts. Under these... Internal Revenue Service 26 CFR Part 48 RIN 1545-BJ44 Taxable Medical Devices AGENCY: Internal...

  7. Developing Linux kernel space device driver

    Institute of Scientific and Technical Information of China (English)

    Zheng Wei; Wang Qinruo; Wu Naiyou

    2003-01-01

    This thesis introduces how to develop kernel level device drivers on Linux platform in detail. On the basis of comparing proc file system with dev file system, we choose PCI devices and USB devices as instances to introduce the method of writing device drivers for character devices by using these two file systems.

  8. Heart failure - surgeries and devices

    Science.gov (United States)

    ... right ventricular assist devices (RVAD) or a total artificial hearts. They are considered for use if you have ... be on a heart-lung bypass machine. Total artificial hearts are being developed, but are not yet in ...

  9. Heart failure - surgeries and devices

    Science.gov (United States)

    ... is weakened, gets too large, and does not pump blood very well, you are at high risk for ... pacemaker. Ventricular assist devices (VAD) help your heart pump blood from the pumping chambers of your heart to ...

  10. Preventing the radiological dispersal device

    International Nuclear Information System (INIS)

    The paper discusses the IAEA plan of action to protect against nuclear terrorism, the nature of the threat of a radiological dispersal device, international instruments for the prevention of nuclear terrorism, recent progress and perspectives for future action. (author)

  11. #DDOD: Establishment Registration & Device Listing

    Data.gov (United States)

    U.S. Department of Health & Human Services — SUMMARY DDOD use case to request means on consolidating multiple data sources (MDR, PMA, 510(k), R&L) in order to build a list of all marketed medical devices....

  12. Device for nuclear reactor control

    International Nuclear Information System (INIS)

    The device for power height distribution control in channel-type uranium-graphite reactor cores is described. The device is a water filled vertical channel positioned in the reactor core. The device consists of a controlling rod, displacer in a form of a throttle and gas cavity and discharge throttle. The rod is fixed in upper position with an electromagnet. By shifting a displacer and changing flow rate established are the required height and position of a controlling liquid column. In the emergency protection, a drive shifts the displacer under core space or the displacer drops under the action of its own weight at electromagnet clutch doenergyzation whereas the channel is filled by liquid. The application of the suggested device permits to improve economic and operating characteristics of reactors

  13. Device for reactor control system

    International Nuclear Information System (INIS)

    A device for nuclear reactor control system is described. The device comprises a channel with control column of neutron absorbing liquid displacer and drain throttle. To increase the reliability and stabilization the control in the flow of liquid, the displacer is fixed to the bar with the help of a rod which length is not less than the half of the core height. The displacer occupies the lower section of the core and divides the column of liquid in two parts consisting of the control column above the displacer and protective column below the drain throttle. The proposed device provides the control of energy distribution along the core height and can be used for leveling energy distribution field or its shaping. A reliable operation of the device is insured, in particular, the stability of such important characteristics as the position and height of the column of liquid, the magnitude of introduced reactivity, the range of controlled parameters

  14. Nanomechanical Water Purification Device Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Seldon Laboratories, LLC, proposes a lightweight, low-pressure water purification device that harnesses the unique properties of carbon nanotubes and will operate...

  15. Nanomechanical Water Purification Device Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Seldon Laboratories, LLC, proposes a lightweight, low-pressure water filtration device that harnesses the unique properties of nanoparticles to destroy or remove...

  16. User Experience of Mobile Devices

    DEFF Research Database (Denmark)

    Raptis, Dimitrios

    that the overall physical form of a mobile device has a significant effect on the perceived usability of an application: the more attractive the physical form, the higher the perceived usability. The other study validated the effect of a particular physical form element on usability and showed that the screen size......This thesis focuses on mobile devices and it specifically investigates the effect of their physical form on two perceived user experience qualities, usability and coolness. With the term mobile devices, I refer to interactive products that users interact with while being on the move......, and with the term physical form I refer to the physical elements that constitute a mobile device as a whole, such as weight, size and materials. The selected research area was addressed through two research questions, one focusing on effects of physical form on usability and the other on effects on coolness...

  17. Integrated Ultrasonic-Photonic Devices

    DEFF Research Database (Denmark)

    Barretto, Elaine Cristina Saraiva

    This thesis deals with the modeling, design, fabrication and characterization of integrated ultrasonic-photonic devices, with particular focus on the use of standard semiconductor materials such as GaAs and silicon. The devices are based on the use of guided acoustic waves to modulate the light in...... channel waveguides and Mach-Zehnder interferometers. Numerical models are developed based on the finite element method, and applied to several scenarios, such as optimization of the geometrical parameters of waveguides, use of slow light in photonic crystal waveguides and use of Lamb waves in membranized...... were investigated. Comparisons are made with the numerical and experimental results, and they validate the obtained response of the acoustic and photonic components of the device. Finally, a new design for an optical frequency shifter is proposed, posing several advantages over existing devices in...

  18. Three-terminal superconducting devices

    International Nuclear Information System (INIS)

    The transistor has a number of properties that make it so useful. The authors discuss these and the additional properties a transistor would need to have for high performance applications at temperatures where superconductivity could contribute advantages to system-level performance. These properties then serve as criteria by which to evaluate three-terminal devices that have been proposed for applications at superconducting temperatures. FETs can retain their transistor properties at low temperatures, but their power consumption is too large for high-speed, high-density cryogenic applications. They discuss in detail why demonstrated superconducting devices with three terminals -Josephson effect based devices, injection controlled weak links, and stacked tunnel junction devices such as the superconducting transistor proposed by K. Gray and the quiteron -- each fail to have true transistor-like properties. They conclude that the potentially very rewarding search for a transistor compatible with superconductivity in high performance applications must be in new directions

  19. Handling device for stud tensioner

    International Nuclear Information System (INIS)

    The handling device for a stud tensioner machine used by example for fixing the reactor vessel head has an extension module, joining elements and means for displacement in vertical and horizontal axis

  20. Polymer electronic devices and materials.

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, William Kent; Baca, Paul Martin; Dirk, Shawn M.; Anderson, G. Ronald; Wheeler, David Roger

    2006-01-01

    Polymer electronic devices and materials have vast potential for future microsystems and could have many advantages over conventional inorganic semiconductor based systems, including ease of manufacturing, cost, weight, flexibility, and the ability to integrate a wide variety of functions on a single platform. Starting materials and substrates are relatively inexpensive and amenable to mass manufacturing methods. This project attempted to plant the seeds for a new core competency in polymer electronics at Sandia National Laboratories. As part of this effort a wide variety of polymer components and devices, ranging from simple resistors to infrared sensitive devices, were fabricated and characterized. Ink jet printing capabilities were established. In addition to promising results on prototype devices the project highlighted the directions where future investments must be made to establish a viable polymer electronics competency.

  1. CPAP Devices for Sleep Apnea

    Science.gov (United States)

    ... CPAP nose masks. In this case, a full-face mask that covers both the nose and the mouth ... could help. Types of CPAP Devices Nasal pillows Face mask Face mask with chin strap Written by familydoctor. ...

  2. Optoelectronic device for hematocrit measurements

    Science.gov (United States)

    Pluta, M.; Milewska, D.; Mazikowski, A.

    2015-09-01

    An optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed system require blood samples (small drop in the range of microliters) which is placed in the micro cuvette. Then, absorption of the sample is measured at wavelengths of 570 nm and 880 nm. Prototype of the device was build and tested. Test results confirmed proper operation of the device with correct metrological parameters in application to HCT level measurements. Such a portable device can be used as a tool of bedside diagnosis, which becomes interesting alternative to full laboratory tests.

  3. Safety device for nuclear reactor

    International Nuclear Information System (INIS)

    This invention relates to a safety device for a nuclear reactor, particularly a liquid metal (generally sodium) cooled fast reactor. This safety device includes an absorbing element with a support head connected by a disconnectable connector formed by the armature of an electromagnet at the end of an axially mobile vertical control rod. This connection is so designed that in the event of it becoming disconnected, the absorbing element gravity slides in a passage through the reactor core into an open container

  4. Trustworthy execution on mobile devices

    CERN Document Server

    Vasudevan, Amit; Newsome, James

    2013-01-01

    This brief considers the various stakeholders in today's mobile device ecosystem, and analyzes why widely-deployed hardware security primitives on mobile device platforms are inaccessible to application developers and end-users. Existing proposals are also evaluated for leveraging such primitives, and proves that they can indeed strengthen the security properties available to applications and users, without reducing the properties currently enjoyed by OEMs and network carriers. Finally, this brief makes recommendations for future research that may yield practical and deployable results.

  5. Operating systems for mobile devices

    OpenAIRE

    Hroch, Jiří

    2012-01-01

    This bachelor thesis is focused on operating systems for mobile devices. The first part is listed first term PC operating system and the most common types of these systems. The operating systems for mobile devices are now chosen the most widely used platforms, which are subsequently described. There is something about their history, development, and are given different versions of these systems.In the second part of this work is compared with popular operating systems today, Android and iOS. ...

  6. Biomedical devices and their applications

    CERN Document Server

    2004-01-01

    This volume introduces readers to the basic concepts and recent advances in the field of biomedical devices. The text gives a detailed account of novel developments in drug delivery, protein electrophoresis, estrogen mimicking methods and medical devices. It also provides the necessary theoretical background as well as describing a wide range of practical applications. The level and style make this book accessible not only to scientific and medical researchers but also to graduate students.

  7. Amorphous silicon based betavoltaic devices

    OpenAIRE

    Wyrsch, N; Riesen, Y.; Franco, A; S. Dunand; Kind, H.; Schneider, S.; Ballif, C.

    2013-01-01

    Hydrogenated amorphous silicon betavoltaic devices are studied both by simulation and experimentally. Devices exhibiting a power density of 0.1 μW/cm2 upon Tritium exposure were fabricated. However, a significant degradation of the performance is taking place, especially during the first hours of the exposure. The degradation behavior differs from sample to sample as well as from published results in the literature. Comparisons with degradation from beta particles suggest an effect of tritium...

  8. Metal semiconductor contacts and devices

    CERN Document Server

    Cohen, Simon S; Einspruch, Norman G

    1986-01-01

    VLSI Electronics Microstructure Science, Volume 13: Metal-Semiconductor Contacts and Devices presents the physics, technology, and applications of metal-semiconductor barriers in digital integrated circuits. The emphasis is placed on the interplay among the theory, processing, and characterization techniques in the development of practical metal-semiconductor contacts and devices.This volume contains chapters that are devoted to the discussion of the physics of metal-semiconductor interfaces and its basic phenomena; fabrication procedures; and interface characterization techniques, particularl

  9. Radiation effects in optoelectronic devices

    International Nuclear Information System (INIS)

    Purpose of this report is to provide not only a summary of radiation damage studies at Sandia National Laboratories, but also of those in the literature on the components of optoelectronic systems: light emitting diodes (LEDs), laser diodes, photodetectors, optical fibers, and optical isolators. This review of radiation damage in optoelectronic components is structured according to device type. In each section, a brief discussion of those device properties relevant to radiation effects is given

  10. The device for bunch selffocussing

    International Nuclear Information System (INIS)

    The new device for damping the longitudinal single bunch instability in atotage rings is proposed. This simple device is the dielectric channel insert of definite length in vacuum chamber. The structure of wake fields, induced by intense bunch in such a channel is that, that backward action on bunch particles not leads to bunch selffocusing. The conditions under which this phenomenon reveals itself and can be applied to electron-positron storages are considered. 3 refs

  11. PKM Mechatronic Clamping Adaptive Device

    OpenAIRE

    Alberto Borboni; Francesco Aggogeri; Angelo Merlo; Nicola Pellegrini; Cinzia Amici

    2015-01-01

    This study proposes a novel adaptive fixturing device based on active clamping systems for smart micropositioning of thin-walled precision parts. The modular architecture and the structure flexibility make the system suitable for various industrial applications. The proposed device is realized as a Parallel Kinematic Machine (PKM), opportunely sensorized and controlled, able to perform automatic error-free workpiece clamping procedures, drastically reducing the overall fixturing set-up time. ...

  12. Lightweight cryptography for constrained devices

    DEFF Research Database (Denmark)

    Alippi, Cesare; Bogdanov, Andrey; Regazzoni, Francesco

    2014-01-01

    Lightweight cryptography is a rapidly evolving research field that responds to the request for security in resource constrained devices. This need arises from crucial pervasive IT applications, such as those based on RFID tags where cost and energy constraints drastically limit the solution...... complexity, with the consequence that traditional cryptography solutions become too costly to be implemented. In this paper, we survey design strategies and techniques suitable for implementing security primitives in constrained devices....

  13. Colour Reproduction on Tablet Devices

    OpenAIRE

    Vladimir Zorić; Igor Karlović

    2014-01-01

    With the advent of Internet and mobile devices client services and other print production are migrating more and more to online platforms. In a recent technology changeover it is obvious that there is growing number of printers as well need from the customers for the print service providers to expand their business to online and mobile platforms. With this technological transition there are some open questions regarding the possibilities of using the tablet devices for colour soft proofing an...

  14. Reference Handbook: Pressure relief devices

    International Nuclear Information System (INIS)

    The purpose of this handbook is to provide Rocky Flats personnel with the information necessary to understand and properly operate pressure relief devices. Upon completion of this handbook you should be able to do the following: Understand the different applications for pressure relief devices. Understand basic properties of gasses and liquids. Understand terminology associated with pressure relief devices. Understand the types, basic construction, and operation of pressure relief devices. Understand pressure relief device operating and troubleshooting practices. This handbook is designed for use by experienced Rocky Flats operators to reinforce and improve their current knowledge level, and by entry-level operators to ensure that they possess a minimum level of fundamental knowledge. Pressure Relief Devices is applicable to many job classifications and can be used as a reference for classroom work or for self-study. Although this reference handbook is by no means all-encompassing, you will gain enough information about this subject area to assist you in contributing to the safe operation of Rocky Flats Plant

  15. Electronic load for testing power generating devices

    Science.gov (United States)

    Friedman, E. B.; Stepfer, G.

    1968-01-01

    Instrument tests various electric power generating devices by connecting the devices to the input of the load and comparing their outputs with a reference voltage. The load automatically adjusts until voltage output of the power generating device matches the reference.

  16. High speed serdes devices and applications

    CERN Document Server

    Stauffer, David R; Sorna, Michael A; Dramstad, Kent; Ogilvie, Clarence Rosser; Amanullah, Mohammad; Rockrohr, James Donald

    2008-01-01

    Offers an understanding of the features and functions typically found on HSS devices. This book explains how these HSS devices are used in protocol applications and the analysis which must be performed to use such HSS devices.

  17. 77 FR 19293 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Meeting

    Science.gov (United States)

    2012-03-30

    ... the Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee. Submit... INFORMATION: Name of Committee: Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory... with or considering hip replacement (...

  18. 77 FR 70464 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2012-11-26

    ... COMMISSION Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data... Telecommunications America, LLC of Richardson, Texas (collectively, ``Samsung''). 76 FR 45860 (Aug. 1, 2011). The... importation of certain electronic devices, including wireless communication devices, portable music and...

  19. 77 FR 60720 - Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data...

    Science.gov (United States)

    2012-10-04

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data... infringing electronic devices, including wireless communication devices, portable music and data...

  20. 78 FR 16865 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2013-03-19

    ... COMMISSION Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data... America, LLC of Richardson, Texas (collectively, ``Samsung''). 76 FR 45860 (Aug. 1, 2011). The complaint... importation of certain electronic devices, including wireless communication devices, portable music and...

  1. Fiber-Optic Communication Technology Branching Devices

    Science.gov (United States)

    Williams, J. C.

    1985-02-01

    This tutorial review of fiber-optic branching devices covers example uses of branching devices, device types, device-performance characteristics, examples of current technology, and system-design methodology. The discussion is limited to passive single- and multimode devices fabricated from optical fibers or graded-index components. Integrated-optic, wavelength-division-multiplexing, and polarization-selective devices are not specifically addressed.

  2. Novel Concepts for Device to Device Communication using Network Coding

    DEFF Research Database (Denmark)

    Pahlevani, Peyman; Hundebøll, Martin; Pedersen, Morten Videbæk;

    2014-01-01

    Device-to-device communication is currently a hot research topic within 3GPP. Even though D2D communication has been part of previous ad hoc, meshed and sensor networks proposals, the main contribution by 3GPP is that the direct communication among two devices is carried out over a dynamically...... assigned, licensed spectrum; thus, it is under full control of the cellular network. D2D communication creates a market potential for new services, new approaches to efficient spectrum use, and security concepts. This is especially true if D2D communication is extended to larger communication groups...... organized in meshed clusters. In this article, we discuss the potential and shortcomings of D2D communication as proposed today, advocating for the use of network coding as an enabling technology for enhanced security and communication efficiency using the PlayNCool and CORE protocols as key examples to...

  3. Contamination detection device for radioactive material transporting device

    International Nuclear Information System (INIS)

    The present invention provides a device for detecting leakage of radioactive materials and clogging of a vial in a radioactive material transporting device. Namely, a transporting tube pneumatically transports the vial containing a sample of radioactive materials. A fine flow tube is laid in adjacent with and along the transporting tube. A pump flows a detection liquid prepared by a preparation device to the fine flow tube. A flow-cell type spectrophotometer is disposed to the fine flow tube. The detection liquid is preferably containing elements having a valency changeable by undergoing radiation irradiation, which is a type used, for example, for a Fricke dosimeter. With such a constitution, the position of the radioactive contamination of the inside of the pneumatic tube and clogging of a vial can be detected only by flowing radiation sensitive detection liquid to the fine flow tube. In addition, the detection liquid is not activated only changing the valency of the contained elements. (N.H.)

  4. Resource management for device-to-device underlay communication

    CERN Document Server

    Song, Lingyang; Xu, Chen

    2013-01-01

    Device-to-Device (D2D) communication will become a key feature supported by next generation cellular networks, a topic of enormous importance to modern communication. Currently, D2D serves as an underlay to the cellular network as a means to increase spectral efficiency. Although D2D communication brings large benefits in terms of system capacity, it also causes interference as well as increased computation complexity to cellular networks as a result of spectrum sharing. Thus, efficient resource management must be performed to guarantee a target performance level of cellular communication.This

  5. 16 CFR 1507.9 - Toy smoke devices and flitter devices.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Toy smoke devices and flitter devices. 1507... SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.9 Toy smoke devices and flitter devices. (a) Toy smoke... fuse and firstfire upon ignition) during normal operation. (b) Toy smoke devices and flitter...

  6. 78 FR 9349 - Medical Devices; Ophthalmic Devices; Classification of the Eyelid Weight

    Science.gov (United States)

    2013-02-08

    ... seq.), as amended by the Medical Device Amendments of 1976 (Pub. L. 94-295), the Safe Medical Devices.../downloads/MedicalDevices/DeviceRegulationandGuidance/Overview/MedicalDeviceUserFeeandModernizationActMDUFMA... HUMAN SERVICES Food and Drug Administration 21 CFR Part 886 Medical Devices; Ophthalmic...

  7. An Overview of Biofield Devices.

    Science.gov (United States)

    Muehsam, David; Chevalier, Gaétan; Barsotti, Tiffany; Gurfein, Blake T

    2015-11-01

    Advances in biophysics, biology, functional genomics, neuroscience, psychology, psychoneuroimmunology, and other fields suggest the existence of a subtle system of "biofield" interactions that organize biological processes from the subatomic, atomic, molecular, cellular, and organismic to the interpersonal and cosmic levels. Biofield interactions may bring about regulation of biochemical, cellular, and neurological processes through means related to electromagnetism, quantum fields, and perhaps other means of modulating biological activity and information flow. The biofield paradigm, in contrast to a reductionist, chemistry-centered viewpoint, emphasizes the informational content of biological processes; biofield interactions are thought to operate in part via low-energy or "subtle" processes such as weak, nonthermal electromagnetic fields (EMFs) or processes potentially related to consciousness and nonlocality. Biofield interactions may also operate through or be reflected in more well-understood informational processes found in electroencephalographic (EEG) and electrocardiographic (ECG) data. Recent advances have led to the development of a wide variety of therapeutic and diagnostic biofield devices, defined as physical instruments best understood from the viewpoint of a biofield paradigm. Here, we provide a broad overview of biofield devices, with emphasis on those devices for which solid, peer-reviewed evidence exists. A subset of these devices, such as those based upon EEG- and ECG-based heart rate variability, function via mechanisms that are well understood and are widely employed in clinical settings. Other device modalities, such a gas discharge visualization and biophoton emission, appear to operate through incompletely understood mechanisms and have unclear clinical significance. Device modes of operation include EMF-light, EMF-heat, EMF-nonthermal, electrical current, vibration and sound, physical and mechanical, intentionality and nonlocality, gas and

  8. Survey of cryogenic semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Talarico, L.J.; McKeever, J.W.

    1996-04-01

    Improved reliability and electronic performance can be achieved in a system operated at cryogenic temperatures because of the reduction in mechanical insult and in disruptive effects of thermal energy on electronic devices. Continuing discoveries of new superconductors with ever increasing values of T{sub c} above that of liquid nitrogen temperature (LNT) have provided incentive for developing semiconductor electronic systems that may also operate in the superconductor`s liquid nitrogen bath. Because of the interest in high-temperature superconductor (HTS) devices, liquid nitrogen is the cryogen of choice and LNT is the temperature on which this review is focused. The purpose of this survey is to locate and assemble published information comparing the room temperature (298 K), performance of commercially available conventional and hybrid semiconductor device with their performance at LNT (77K), to help establish their candidacy as cryogenic electronic devices specifically for use at LNT. The approach to gathering information for this survey included the following activities. Periodicals and proceedings were searched for information on the behavior of semiconductor devices at LNT. Telephone calls were made to representatives of semiconductor industries, to semiconductor subcontractors, to university faculty members prominent for their research in the area of cryogenic semiconductors, and to representatives of the National Aeronautics and Space Administration (NASA) and NASA subcontractors. The sources and contacts are listed with their responses in the introduction, and a list of references appears at the end of the survey.

  9. Radioactive gaseous waste processing device

    International Nuclear Information System (INIS)

    In a radioactive gaseous waste processing device, a dehumidifier in which a lot of hollow thread membranes are bundled and assembled is disposed instead of a dehumidifying cooling device and a dehumidifying tower. The dehumidifier comprises a main body, a great number of hollow thread membranes incorporated in the main body, a pair of fixing members for bundling and fixing both ends of the hollow thread membranes, a pair of caps for allowing the fixing members to pass through and fixing them on both ends of the main body, an off gas flowing pipe connected to one of the caps, a gas exhaustion pipe connected to the other end of the cap and a moisture removing pipeline connected to the main body. A flowrate control valve is connected to the moisture removing pipeline, and the other end of the moisture removing pipeline is connected between a main condensator and an air extraction device. Then, cooling and freezing devices using freon are no more necessary, and since the device uses the vacuum of the main condensator as a driving source and does not use dynamic equipments, labors for the maintenance is greatly reduced to improve economical property. The facilities are reduced in the size thereby enabling to use space effectively. (N.H.)

  10. CIRSE Vascular Closure Device Registry

    International Nuclear Information System (INIS)

    Purpose: Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. Methods: The CIRSE registry of closure devices with an anchor and a plug started in January 2009 and ended in August 2009. A total of 1,107 patients were included in the registry. Results: Deployment success was 97.2%. Deployment failure specified to access type was 8.8% [95% confidence interval (95% CI) 5.0–14.5] for antegrade access and 1.8% (95% CI 1.1–2.9) for retrograde access (P = 0.001). There was no difference in deployment failure related to local PVD at the access site. Calcification was a reason for deployment failure in only 5.9 cm, and two vessel occlusions. Conclusion: The conclusion of this registry of closure devices with an anchor and a plug is that the use of this device in interventional radiology procedures is safe, with a low incidence of serious access site complications. There seems to be no difference in complications between antegrade and retrograde access and other parameters.

  11. Self-forming nanoscale devices

    Directory of Open Access Journals (Sweden)

    Lars Samuelson

    2003-10-01

    The top-down approach limits the dimensions of devices to what is technically achievable using lithography. This is the means by which patterns can be drawn, either in stone as the Vikings did when they carved messages into granite, or into Si as the electronics industry does today to build integrated circuits. Lithographic techniques can create device features as narrow as 130 nm and the industry sees the road ahead pretty well drawn up for line-widths down to ∼50 nm. This continued progress does not come without a price; the cost of new fabs is growing extremely fast, at a pace that may limit continued progress, simply because devices and circuits become too expensive to be economically viable.

  12. Spintronic devices as quantum networks

    CERN Document Server

    Ionicioiu, R

    2005-01-01

    We explore spintronics from a quantum information (QI) perspective. We show that QI specific methods can be an effective tool in designing new devices. Using the formalism of quantum gates acting on spin and mode degrees of freedom, we provide a solution to a reverse engineering problem, namely how to design a device performing a given transformation between input and output. Among these, we describe an orientable Stern-Gerlach device and a new scheme to entangle two spins by transferring the entanglement from orbital to spin degrees of freedom. Finally, we propose a simple scheme to produce hyper-entangle electrons, i.e., particles entangled in both spin and mode degrees of freedom.

  13. Advanced Mechatronics and MEMS Devices

    CERN Document Server

    2013-01-01

    Advanced Mechatronics and MEMS Devicesdescribes state-of-the-art MEMS devices and introduces the latest technology in electrical and mechanical microsystems. The evolution of design in microfabrication, as well as emerging issues in nanomaterials, micromachining, micromanufacturing and microassembly are all discussed at length in this volume. Advanced Mechatronics also provides a reader with knowledge of MEMS sensors array, MEMS multidimensional accelerometer, artificial skin with imbedded tactile components, as well as other topics in MEMS sensors and transducers. The book also presents a number of topics in advanced robotics and an abundance of applications of MEMS in robotics, like reconfigurable modular snake robots, magnetic MEMS robots for drug delivery and flying robots with adjustable wings, to name a few. This book also: Covers the fundamentals of advanced mechatronics and MEMS devices while also presenting new state-of-the-art methodology and technology used in the application of these devices Prese...

  14. Electrically tunable infrared metamaterial devices

    Science.gov (United States)

    Brener, Igal; Jun, Young Chul

    2015-07-21

    A wavelength-tunable, depletion-type infrared metamaterial optical device is provided. The device includes a thin, highly doped epilayer whose electrical permittivity can become negative at some infrared wavelengths. This highly-doped buried layer optically couples with a metamaterial layer. Changes in the transmission spectrum of the device can be induced via the electrical control of this optical coupling. An embodiment includes a contact layer of semiconductor material that is sufficiently doped for operation as a contact layer and that is effectively transparent to an operating range of infrared wavelengths, a thin, highly doped buried layer of epitaxially grown semiconductor material that overlies the contact layer, and a metallized layer overlying the buried layer and patterned as a resonant metamaterial.

  15. Survey of hydrogen monitoring devices

    International Nuclear Information System (INIS)

    Presented are results of a survey of commercially available monitoring devices suitable for hydrogen detection in the secondary containment vessel of a nuclear power plant during the post postulated accident period. Available detectors were grouped into the following five classes: combustion, solid state, electrochemical, thermal conductivity, and absorption. The performance of most available sensors is likely to deteriorate when exposed to the postulated conditions which include moisture, which could be at high temperature, and radioactive noncondensibles. Of the commercial devices, those using metallic filament thermal conductivity detectors seem least susceptible to performance change. Absorption detectors are best suited for this monitoring task but the only available device is designed for pipeline corrosion assessment. Initiation of experimental study to assess apparent deficiencies of commercial detectors is recommended. Also recommended is an analytical/experimental effort to determine the optimum detector array for monitoring in the secondary containment vessels

  16. Incore inspection and repairing device

    International Nuclear Information System (INIS)

    The present invention provides a device for inspecting and repairing the inside of a reactor container even if it is narrow, with no trouble by using a swimming-type operation robot. Namely, the device of the present invention conducts inspection and repairing operations for the inside of the reactor by introducing a swimming type operation robot into the reactor container. The swimming-type operation robot comprises a robot main body having a propeller, a balancer operably disposed to the robot main body and an inspection and repairing unit attached detachable to the balancer. In the device of the present invention, since the inspection and preparing unit is attached detachably to the swimming robot, a robot which transports tools is formed as a standard product. As a result, the production cost can be reduced, and the reliability of products can be improved. Appropriate operations can be conducted by using best tools. (I.S.)

  17. Signal processing devices and networks

    Science.gov (United States)

    Graveline, S. W.

    1985-02-01

    According to an axiom employed with respect to electronic warfare (EW) behavior, system effectiveness increases directly with the amount of information recovered from an intercepted signal. The evolution in EW signal processing capability has proceeded accordingly. After an initiation of EW systems as broadband receivers, the most significant advance was related to the development of digital instantaneous frequency measurement (DIFM) devices. The use of such devices provides significant improvements regarding signal identification and RF measurement to within a few MHz. An even more accurate processing device, the digital RF memory (DRFM), allows frequency characterization to within a few Hz. This invention was made in response to the need to process coherent pulse signals. Attention is given to the generic EW system, the modern EW system, and the generic receiver function for a modern EW system showing typical output signals.

  18. Digital Devices and Distracted Doctoring.

    Science.gov (United States)

    Dossey, Garry

    2015-04-01

    During the past twenty years a digital sea change has affected our world. Digital devices have changed the way we live and especially the way we work in our professions. As dentists, we are able to work with far greater accuracy and precision than ever before; we would be foolish not to embrace these advances. But, as is often the case with rapid cultural changes, we need to be aware of the possibility of unintended consequences that may accompany this revolution. Sound scientific studies are beginning to warn of the psychological and physiological problems of overuse of digital devices in our daily lives. We should remember that these devices are neutral. It is up to each of us to use them in ways that enhance patient care. PMID:26234105

  19. Silicon Nano-Photonic Devices

    DEFF Research Database (Denmark)

    Pu, Minhao

    This thesis deals with the design, fabrication and characterization of nano-photonic devices including ridge waveguide components, microring resonators, and photonic crystal components, and explore the potential for these devices in dierent applications ranging from optical communication to...... achieved with small power variation. A widely tunable microwave notch lter is also experimentally demonstrated at 40 GHz. Other application such as pulse repetition rate multiplication by using microring resonator is also presented. Photonic crystal components are studied. Two dierent types of photonic...... crystal structures are analyzed concerning index sensitivity, dispersion engineering, and slow-light coupling. Several photonic crystal devices such as index sensor, slow-light coupler, and all-optical tunable cavity are presented....

  20. Linerless label device and method

    KAUST Repository

    Binladen, Abdulkari

    2016-01-14

    This apparatus and method for applying a linerless label to an end user product includes a device with a printer for printing on a face surface of a linerless label, and a release coat applicator for applying a release coat to the face surface of the label; another device including an unwinder unit (103) to unwind a roll of printed linerless label; a belt (108); a glue applicator (102) for applying glue to the belt; a nip roller (106) for contacting and applying pressure to the face surface of the linerless label such that the glue on the belt transfers to the back surface of the linerless label; at least one slitting knife 105) positioned downstream the belt and a rewinder unit (104) positioned downstream the slitting knife; and a third device which die cuts and applies the linerless label to an end user object.

  1. High-power active devices

    CERN Document Server

    Carroll, E

    2006-01-01

    Very high-power (HP) electronics represents a small part of the electronics market. In semiconductor terms, HP represents a world device market of 600 million euros out of a total 200 billion euros for all semiconductors—a mere 0.3 per cent. At the multi-megawatt spectral end, the numbers are even smaller, so that it is quite common for electronics engineers to be unaware of developments in Very High Power (VHP). In this presentation we discuss the categories of VHP active devices, the basic topologies in which they operate, and the trend towards higher voltage and current. New press-pack technologies are introduced and the salient differences between Insulated Gate Bipolar Transistors (IGBTs) and Integrated Gate Commutated Thyristors (IGCTs) are compared. Finally, recent developments in turn-off ratings for both these devices are presented.

  2. Colour Reproduction on Tablet Devices

    Directory of Open Access Journals (Sweden)

    Vladimir Zorić

    2014-07-01

    Full Text Available With the advent of Internet and mobile devices client services and other print production are migrating more and more to online platforms. In a recent technology changeover it is obvious that there is growing number of printers as well need from the customers for the print service providers to expand their business to online and mobile platforms. With this technological transition there are some open questions regarding the possibilities of using the tablet devices for colour soft proofing and other colour related operations. As a display devices on a hardware level there are large similarities with the desktop display devices but the operating systems which are driving them are not yet colour smart. There have been some initial attempts to characterize the colour reproduction on this type of devices and find a possibility of using them not just for information content but also for colour managed content. In this study we have tested several tablets (Apple iPad2,Asus Transformer TF101, Samsung Galaxy Tab 1 with different display and OS technology and tested a software which is intended for colour managed viewing of the reproduction. We have measured the colour reproduction of the tablets with the digital version of the GretagMacbeth ColorChecker card and have calculated the colour differences between the colour chart data and the displayed data. We have calibrated the Ipad2 with the only existing colour management tool the Spyder Gallery and we have also tested the chart display with and without the colour correction of the software. We have found that there are differences in the colour reproduction of the display technologies and that the possibilities of a real colour managed workflow has yet to be resolved on the OS level of tablet and mobile devices

  3. Device-independent randomness amplification with a single device

    International Nuclear Information System (INIS)

    Expansion and amplification of weak randomness with untrusted quantum devices has recently become a very fruitful topic of research. Here we contribute with a procedure for amplifying a single weak random source using tri-partite GHZ-type entangled states. If the quality of the source reaches a fixed threshold R=log2⁡(10), perfect random bits can be produced. This technique can be used to extract randomness from sources that can't be extracted neither classically, nor by existing procedures developed for Santha–Vazirani sources. Our protocol works with a single fault-free device decomposable into three non-communicating parts, that is repeatedly reused throughout the amplification process. - Highlights: • We propose a protocol for device independent randomness amplification. • Our protocol repeatedly re-uses a single device decomposable into three parts. • Weak random sources with min-entropy rate greater than 1/4 log2⁡(10) can be amplified. • Security against all-quantum adversaries is achieved

  4. Microfluidic device for drug delivery

    Science.gov (United States)

    Beebe, David J. (Inventor); MacDonald, Michael J. (Inventor); Eddington, David T. (Inventor); Mensing, Glennys A. (Inventor)

    2010-01-01

    A microfluidic device is provided for delivering a drug to an individual. The microfluidic device includes a body that defines a reservoir for receiving the drug therein. A valve interconnects the reservoir to an output needle that is insertable into the skin of an individual. A pressure source urges the drug from the reservoir toward the needle. The valve is movable between a closed position preventing the flow of the drug from the reservoir to the output needle and an open position allowing for the flow of the drug from the reservoir to the output needle in response to a predetermined condition in the physiological fluids of the individual.

  5. Electromedical devices test laboratories accreditation

    Science.gov (United States)

    Murad, C.; Rubio, D.; Ponce, S.; Álvarez Abri, A.; Terrón, A.; Vicencio, D.; Fascioli, E.

    2007-11-01

    In the last years, the technology and equipment at hospitals have been increase in a great way as the risks of their implementation. Safety in medical equipment must be considered an important issue to protect patients and their users. For this reason, test and calibrations laboratories must verify the correct performance of this kind of devices under national and international standards. Is an essential mission for laboratories to develop their measurement activities taking into account a quality management system. In this article, we intend to transmit our experience working to achieve an accredited Test Laboratories for medical devices in National technological University.

  6. Price transparency for medical devices.

    Science.gov (United States)

    Pauly, Mark V; Burns, Lawton R

    2008-01-01

    Hospital buyers of medical devices contract with manufacturers with market power that sell differentiated products. The medical staff strongly influences hospitals' choice of devices. Sellers have sought to limit disclosure of transaction prices. Policy-makers have proposed legislation mandating disclosure, in the interest of greater transparency. We discuss why a manufacturer might charge different prices to different hospitals, the role that secrecy plays, and the consequences of secrecy versus disclosure. We argue that hospital-physician relationships are key to understanding what manufacturers gain from price discrimination. Price disclosure can catalyze a restructuring of those relationships, which, in turn, can improve hospital bargaining. PMID:18997210

  7. Irradiation device for electronic circuits

    International Nuclear Information System (INIS)

    The device includes a radiation-tight vessel, a mobile carriage for a radioactive source, a vertically mobile plate carrying a circuit to be tested and an irradiation detector. It includes also a cover related to the vacuum vessel which prevents the source from emitting for a certain source position. It includes also means which prevents irradiation when the vessel is not assembled and which prevents the dismantling when the source is radiating. It includes also a device allowing to disconnect the translation displacement controls of the circuit and of the radiation detector when the source is radiating

  8. A sealing device for shafts

    International Nuclear Information System (INIS)

    The invention relates to a sealing device for a rotary shaft submitted to variable forces able to bend said shaft. The shaft extends through an opening in a casing and carries a ring comprising radial sealing surfaces adapted to engage axially moving sealing members, the latter being in sealed engagement with the casing and defining a sealing chamber to which is fed a pressurized sealing fluid. In that device, the shaft can be submitted to an important bending without inducing any axial movement, or with a small axial movement of the sealing members. This can be applied to butterfly-valves used in nuclear power stations

  9. Wide gap semiconductor microwave devices

    International Nuclear Information System (INIS)

    A review of properties of wide gap semiconductor materials such as diamond, diamond-like carbon films, SiC, GaP, GaN and AlGaN/GaN that are relevant to electronic, optoelectronic and microwave applications is presented. We discuss the latest situation and perspectives based on experimental and theoretical results obtained for wide gap semiconductor devices. Parameters are taken from the literature and from some of our theoretical works. The correspondence between theoretical results and parameters of devices is critically analysed. (review article)

  10. Flexible spintronic devices on Kapton

    DEFF Research Database (Denmark)

    Bedoya-Pinto, Amilcar; Donolato, Marco; Gobbi, Marco;

    2014-01-01

    Magnetic tunnel junctions and nano-sized domain-wall conduits have been fabricated on the flexible substrate Kapton. Despite the delicate nature of tunneling barriers and zig-zag shaped nanowires, the devices show an outstanding integrity and robustness upon mechanical bending. High values of...... bending angle (r = 5 mm) have been achieved without degradation of the device performance, reaching room-temperature tunneling magnetoresistance ratios of 12% in bended Co/Al2O3/NiFe junctions. In addition, a suitable route to pattern high-quality nanostructures directly on the polyimide surface is...

  11. Cooling device of superconducting coils

    International Nuclear Information System (INIS)

    This device is rotating around an horizontal axis. The superconducting coils are contained in a cryogenic enclosure feeded in liquid helium forced circulation. They are related to an electric generator by electric mains each of them comprising a gas exchanger, and an exchanger-evaporator set between the cryogenic device and those exchangers. The exchanger-evaporator is aimed at dissipating the heat arriving by conductors connected to the superconducting coils. According to the invention, the invention includes an annular canalization with horizontal axis in which the connection conductors bathe in liquid helium

  12. Metamaterials for terahertz polarimetric devices

    Energy Technology Data Exchange (ETDEWEB)

    O' hara, John F [Los Alamos National Laboratory; Taylor, Antoinette J [Los Alamos National Laboratory; Smirnova, Evgenya [Los Alamos National Laboratory; Azad, Abul [Los Alamos National Laboratory; Chen, Hou-tong [Los Alamos National Laboratory; Peralta, Xomalin G [SNL; Brener, Igal [SNL

    2008-01-01

    We present experimental and numerical investigations of planar terahertz metamaterial structures designed to interact with the state of polarization. The dependence of metamaterial resonances on polarization results in unique amplitude and phase characteristics of the terahertz transmission, providing the basis for polarimetric terahertz devices. We highlight some potential applications for polarimetric devices and present simulations of a terahertz quarter-wave plate and a polarizing terahertz beam splitter. Although this work was performed at tcrahertz frequencies, it may find applications in other frequency ranges as well.

  13. Metamaterials for terahertz polarimetric devices

    Energy Technology Data Exchange (ETDEWEB)

    O' hara, John F [Los Alamos National Laboratory; Taylor, Antoinette J [Los Alamos National Laboratory; Smirnova, Evgenya [Los Alamos National Laboratory; Azad, Abul [Los Alamos National Laboratory

    2008-01-01

    We present experimental and numerical investigations of planar terahertz metamaterial structures designed to interact with the state of polarization. The dependence of metamaterial resonances on polarization results in unique amplitude and phase characteristics of the terahertz transmission, providing the basis for polarimetric terahertz devices. We highlight some potential applications for polarimetric devices and present simulations of a terahertz quarter-wave plate and a polarizing terahertz beam splitter. Although this work was performed at terahertz frequencies, it may find applications in other frequency ranges as well.

  14. Electromagnetic device of linear displacement

    International Nuclear Information System (INIS)

    The device moves a rod integral with a nuclear reactor control element. It has a grab for the rod operated by a mobil pole drive by a coil carried by a surrounding sealed casing, a second grab with fixed and mobile poles with facing surfaces shaped to limit the variation of magnetic force with distance between them, and a plunger driven by a coil to bear against another mobile pole moved by a coil. The invention proposes a device ensuring a displacement while the impact forces at the different level of the mechanism are reduced

  15. Medical devices and human engineering

    CERN Document Server

    Bronzino, Joseph D

    2014-01-01

    Known as the bible of biomedical engineering, The Biomedical Engineering Handbook, Fourth Edition, sets the standard against which all other references of this nature are measured. As such, it has served as a major resource for both skilled professionals and novices to biomedical engineering.Medical Devices and Human Engineering, the second volume of the handbook, presents material from respected scientists with diverse backgrounds in biomedical sensors, medical instrumentation and devices, human performance engineering, rehabilitation engineering, and clinical engineering.More than three doze

  16. Documentation of Appliances & Interaction Devices

    DEFF Research Database (Denmark)

    2004-01-01

    The interaction devices and appliances explored in the WorkSPACE project, address spatial computing in the context of work. We have developed and explored a range of appliances and interaction devices. The scope has been to develop tools for support of collaboration by mixing digital and physical...... materials and environments. This has been done by the use of existing hardware technologies in novel combinations, controlled and mediated in the software applications we have developed. These developments, (the SpacePanel, the TagTable and ProjecTable , the SitePack and the software application Topos...

  17. Review of catheter thrombectomy devices.

    Science.gov (United States)

    Suarez, Jose A; Meyerrose, Gary E; Phisitkul, Sorot; Kennedy, Shalyn; Roongsritong, Chanwit; Tsikouris, James; Huang, Shoei K Stephen

    2004-01-01

    Acute massive pulmonary embolism (PE) is a frequently fatal event that causes significant compromise of hemodynamic stability. Unfortunately, mortality rates for PE have remained relatively constant despite advances in prophylactic and treatment measures. In addition to embolus size, symptom recognition for diagnosis and emergent treatment are two distinct factors that dictate survival. Treatment generally includes thrombolytic agents; however, not all patients are candidates for aggressive thrombolytic management. Development of catheter thrombectomy devices provides an alternative treatment modality for severe cases when thrombolytics are contraindicated. Catheter thrombectomy devices have undergone major advances over the last decade, but literature support of their success is limited. PMID:14988612

  18. Materials for energy conversion devices

    CERN Document Server

    Sorrell, C C; Sugihara, S

    2005-01-01

    As the finite capacity and pollution problems of fossil fuels grow more pressing, new sources of more sustainable energy are being developed. Materials for energy conversion devices summarises the key research on new materials which can be used to generate clean and renewable energy or to help manage problems from existing energy sources. The book discusses the range of materials that can be used to harness and convert solar energy in particular, including the properties of oxide materials and their use in producing hydrogen fuel. It covers thermoelectric materials and devices for power genera

  19. Wireless Power for Mobile Devices

    OpenAIRE

    Waffenschmidt, E.

    2011-01-01

    Wireless power transfer allows a convenient, easy to use battery charging of mobile phones and other mobile devices. No hassle with cables and plugs, just place the device on a pad and that’s it. Such asystem even has the potential to become a standard charging solution. Where are the limits for such a solution and which are the side conditions to consider? What are the possibilities to realize such a system? To make the whole idea a success, it is definitely necessaryto come to widely accept...

  20. Semiconductor-based, large-area, flexible, electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Goyal, Amit (Knoxville, TN)

    2011-03-15

    Novel articles and methods to fabricate the same resulting in flexible, large-area, triaxially textured, single-crystal or single-crystal-like, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

  1. Medical Devices; General Hospital and Personal Use Devices; Classification of the Ultraviolet Radiation Chamber Disinfection Device. Final order.

    Science.gov (United States)

    2015-11-20

    The Food and Drug Administration (FDA or the Agency) is classifying the ultraviolet (UV) radiation chamber disinfection device into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the UV radiation chamber disinfection device classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device. PMID:26595943

  2. 77 FR 72924 - Taxable Medical Devices

    Science.gov (United States)

    2012-12-07

    ...'' are not taxable medical devices. The definition of a device in section 201(h) of the FFDCA includes... Internal Revenue Service 26 CFR Part 48 RIN 1545-BJ44 Taxable Medical Devices AGENCY: Internal Revenue... provide guidance on the excise tax imposed on the sale of certain medical devices, enacted by the...

  3. 78 FR 18233 - Medical Devices; Technical Amendment

    Science.gov (United States)

    2013-03-26

    .../ MedicalDevices/ pma/. DeviceRegulationa ndGuidance/ HowtoMarketYourDe vice/ PremarketSubmissi ons..., 876, 878, 880, 882, 884, 886, 888, 890, and 892 Medical Devices; Technical Amendment AGENCY: Food and... outdated Web site addresses affecting certain regulations regarding medical devices. Publication of...

  4. 21 CFR 890.5525 - Iontophoresis device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Iontophoresis device. 890.5525 Section 890.5525 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5525...

  5. 77 FR 40735 - Unique Device Identification System

    Science.gov (United States)

    2012-07-10

    ... when the device is no longer accompanied by its label or package. The principles behind the rule's... would require the label of medical devices and device packages to include a unique device identifier... Collection Requirements'' section of this document). See section VII for the proposed effective date of...

  6. Ultrafast Spectroscopy of Semiconductor Devices

    DEFF Research Database (Denmark)

    Borri, Paola; Langbein, Wolfgang; Hvam, Jørn Marcher

    In this work we present an experimental technique for investigating ultrafast carrier dynamics in semiconductor optical amplifiers at room temperature. These dynamics, influenced by carrier heating, spectral hole-burning and two-photon absorption, are very important for device applications in inf...

  7. Method of making optoelectric devices

    DEFF Research Database (Denmark)

    2012-01-01

    A method of preparing an optoelectric device, comprising: (a) providing a substrate on which is formed a first electrode layer; (b) forming an electron transport layer according to the following method: i) forming a film of a coating ink comprising zinc acetate in aqueous solution; ii) drying the...

  8. Nanophotonic Devices for Optical Interconnect

    DEFF Research Database (Denmark)

    Van Thourhout, D.; Spuesens, T.; Selvaraja, S.K.;

    2010-01-01

    We review recent progress in nanophotonic devices for compact optical interconnect networks. We focus on microdisk-laser-based transmitters and discuss improved design and advanced functionality including all-optical wavelength conversion and flip-flops. Next we discuss the fabrication uniformity...

  9. Topology Optimization of Nanophotonic Devices

    DEFF Research Database (Denmark)

    Yang, Lirong

    This thesis explores the various aspects of utilizing topology optimization in designing nanophotonic devices. Either frequency-domain or time-domain methods is used in combination with the optimization algorithms, depending on various aims of the designing problems. The frequency-domain methods...

  10. An active magnetic regenerator device

    DEFF Research Database (Denmark)

    2015-01-01

    A rotating active magnetic regenerator (AMR) device comprising two or more regenerator beds, a magnet arrangement and a valve arrangement. The valve arrangement comprises a plurality of valve elements arranged substantially immovably with respect to the regenerator beds along a rotational direction...

  11. Wavelength conversion techniques and devices

    DEFF Research Database (Denmark)

    Danielsen, Søren Lykke; Mikkelsen, Benny; Hansen, Peter Bukhave;

    1997-01-01

    interesting for use in WDM optical fibre networks. However, the perfect converter has probably not yet been fabricated and new techniques such as conversion relying on cross-absorption modulation in electro-absorption modulators might also be considered in pursue of effective conversion devices...

  12. Specialized device of power supplies

    Directory of Open Access Journals (Sweden)

    Gunchenko Y. A.

    2010-02-01

    Full Text Available The specialized device of power supplies, capable to change parameters of output voltage depending on conditions of environment and parameters of the fed equipment is offered. Examples of its application for feed of the electroluminescent indicator are resulted.

  13. Featured Invention: Laser Scaling Device

    Science.gov (United States)

    Dunn, Carol Anne

    2008-01-01

    In September 2003, NASA signed a nonexclusive license agreement with Armor Forensics, a subsidiary of Armor Holdings, Inc., for the laser scaling device under the Innovative Partnerships Program. Coupled with a measuring program, also developed by NASA, the unit provides crime scene investigators with the ability to shoot photographs at scale without having to physically enter the scene, analyzing details such as bloodspatter patterns and graffiti. This ability keeps the scene's components intact and pristine for the collection of information and evidence. The laser scaling device elegantly solved a pressing problem for NASA's shuttle operations team and also provided industry with a useful tool. For NASA, the laser scaling device is still used to measure divots or damage to the shuttle's external tank and other structures around the launchpad. When the invention also met similar needs within industry, the Innovative Partnerships Program provided information to Armor Forensics for licensing and marketing the laser scaling device. Jeff Kohler, technology transfer agent at Kennedy, added, "We also invited a representative from the FBI's special photography unit to Kennedy to meet with Armor Forensics and the innovator. Eventually the FBI ended up purchasing some units. Armor Forensics is also beginning to receive interest from DoD [Department of Defense] for use in military crime scene investigations overseas."

  14. Silicon carbide materials, processing & devices

    CERN Document Server

    Zhe, Chuan Feng

    2003-01-01

    This book will provide useful information to material growers and evaluators, device design and processing engineers as well as potential users of SiC technologies. This book will help identify remaining challenging issues to stimulate further investigation to realize the full potential of wide band gap SiC for optoelectronic and microelectronic applications.

  15. Ultrafast Spectroscopy of Semiconductor Devices

    DEFF Research Database (Denmark)

    Borri, Paola; Langbein, Wolfgang; Hvam, Jørn Marcher

    1999-01-01

    In this work we present an experimental technique for investigating ultrafast carrier dynamics in semiconductor optical amplifiers at room temperature. These dynamics, influenced by carrier heating, spectral hole-burning and two-photon absorption, are very important for device applications in...

  16. Mechatronic Device for Elbow Rehabilitation

    Directory of Open Access Journals (Sweden)

    Fausti Davide

    2016-01-01

    Full Text Available This work proposes a mechatronic device for elbow rehabilitation. The realized therapy is based on continuous passive motion. A prototype was realized and design and dimensioning is here presented. Preliminary tests will be performed on non-pathological subjects to allow clinical experiments.

  17. Measuring verification device error rates

    International Nuclear Information System (INIS)

    A verification device generates a Type I (II) error when it recommends to reject (accept) a valid (false) identity claim. For a given identity, the rates or probabilities of these errors quantify random variations of the device from claim to claim. These are intra-identity variations. To some degree, these rates depend on the particular identity being challenged, and there exists a distribution of error rates characterizing inter-identity variations. However, for most security system applications we only need to know averages of this distribution. These averages are called the pooled error rates. In this paper the authors present the statistical underpinnings for the measurement of pooled Type I and Type II error rates. The authors consider a conceptual experiment, ''a crate of biased coins''. This model illustrates the effects of sampling both within trials of the same individual and among trials from different individuals. Application of this simple model to verification devices yields pooled error rate estimates and confidence limits for these estimates. A sample certification procedure for verification devices is given in the appendix

  18. Terahertz Semiconductor Quantum Well Devices

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    For eventually providing terahertz science with compact and convenient devices,terahertz (1~10THz) quantum-well photodetectors and quantum-cascade lasers are investigated. The design and projected detector performance are presented together with experimental results for several test devices,all working at photon energies below and around optical phonons. Background limited infrared performance (BLIP) operations are observed for all samples (three in total) ,designed for different wavelengths. BLIP temperatures of 17,13, and 12K are achieved for peak detection frequencies of 9.7THz(31μm) ,5.4THz(56μm) ,and 3.2THz(93μm) ,respectively. A set of THz quantum-cascade lasers with identical device parameters except for doping concentration is studied. The δ-doping density for each period varies from 3.2 × 1010 to 4. 8 × 1010cm-2. We observe that the lasing threshold current density increases monotonically with doping concentration. Moreover, the measurements for devices with different cavity lengths provide evidence that the free carrier absorption causes the waveguide loss also to increase monotonically. Interestingly the observed maximum lasing temperature is best at a doping density of 3.6 × 1010cm-2.

  19. High performance thermoelectric nanocomposite device

    Science.gov (United States)

    Yang, Jihui; Snyder, Dexter D.

    2011-10-25

    A thermoelectric device includes a nanocomposite material with nanowires of at least one thermoelectric material having a predetermined figure of merit, the nanowires being formed in a porous substrate having a low thermal conductivity and having an average pore diameter ranging from about 4 nm to about 300 nm.

  20. Mobile Devices in the Classroom

    Science.gov (United States)

    Schachter, Ron

    2009-01-01

    As cell phones--with ever-expanding possibilities of texting, Web browsing, and game playing--have multiplied in recent years among teenagers and even preteens, so have the concerns of teachers and administrators about the distractions these devices can cause. A survey of students and parents earlier this year by the group Common Sense Media found…

  1. Electrohydraulic ventricular assist device development.

    Science.gov (United States)

    Diegel, P D; Mussivand, T; Holfert, J W; Juretich, J T; Miller, J A; Maclean, G K; Szurmak, Z; Santerre, J P; Rajagopalan, K; Dew, P A

    1992-01-01

    An electrohydraulic ventricular assist device has been developed. An axial flow pump driven by a brushless DC motor provides actuation. Energy is supplied by internal Ni/Cd batteries and by external Ag/Zn batteries, both rechargeable. Electromagnetic induction is used to pass energy through the skin with a transcutaneous energy transfer (TET) system. Physiologic control, battery management, motor commutation, and communication functions are performed by a surface mount internal controller. An infrared data link within the TET coils provides bidirectional communication between the external and internal controllers. A computer model was developed to predict system performance. The dimensions are 180 mm x 116 mm x 40 mm. An in vitro system pumped 5.7 L/min at 10 mmHg inflow and 100 mmHg outflow pressure. The internal battery can provide the projected energy requirements for 40 min after 540 charge/discharge cycles, and the external battery is capable of 4 hr of operation after 150 cycles. The TET system can deliver 60 W of power and exceeds 80% efficiency between 15 and 30 W. The device configuration is based on human cadaver and intraoperative fit trials. The device is being modified for calf implantation by redirecting the blood ports, increasing the output, and incorporating the internal controller in the unified device base. PMID:1457871

  2. Transmyocardial revascularization devices: technology update

    Directory of Open Access Journals (Sweden)

    Kindzelski BA

    2014-12-01

    Full Text Available Bogdan A Kindzelski, Yifu Zhou, Keith A Horvath Cardiothoracic Surgery Research Program, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA Abstract: Transmyocardial laser revascularization (TMR emerged as treatment modality for patients with diffuse coronary artery disease not amendable to percutaneous or surgical revascularization. The procedure entails the creation of laser channels within ischemic myocardium in an effort to better perfuse these areas. Currently, two laser devices are approved by the US Food and Drug Administration for TMR – holmium:yttrium–aluminum–garnet and CO2. The two devices differ in regard to energy outputs, wavelengths, ability to synchronize with the heart cycle, and laser–tissue interactions. These differences have led to studies showing different efficacies between the two laser devices. Over 50,000 procedures have been performed worldwide using TMR. Improvements in angina stages, quality of life, and perfusion of the myocardium have been demonstrated with TMR. Although several mechanisms for these improvements have been suggested, evidence points to new blood vessel formation, or angiogenesis, within the treated myocardium, as the major contributory factor. TMR has been used as sole therapy and in combination with coronary artery bypass grafting. Clinical studies have demonstrated that TMR is both safe and effective in angina relief long term. The objective of this review is to present the two approved laser devices and evidence for the safety and efficacy of TMR, along with future directions with this technology. Keywords: laser, revascularization, angiogenesis, coronary artery disease

  3. SRV-automatic handling device

    International Nuclear Information System (INIS)

    Automatic handling device for the steam relief valves (SRV's) is developed in order to achieve a decrease in exposure of workers, increase in availability factor, improvement in reliability, improvement in safety of operation, and labor saving. A survey is made during a periodical inspection to examine the actual SVR handling operation. An SRV automatic handling device consists of four components: conveyor, armed conveyor, lifting machine, and control/monitoring system. The conveyor is so designed that the existing I-rail installed in the containment vessel can be used without any modification. This is employed for conveying an SRV along the rail. The armed conveyor, designed for a box rail, is used for an SRV installed away from the rail. By using the lifting machine, an SRV installed away from the I-rail is brought to a spot just below the rail so that the SRV can be transferred by the conveyor. The control/monitoring system consists of a control computer, operation panel, TV monitor and annunciator. The SRV handling device is operated by remote control from a control room. A trial equipment is constructed and performance/function testing is carried out using actual SRV's. As a result, is it shown that the SRV handling device requires only two operators to serve satisfactorily. The required time for removal and replacement of one SRV is about 10 minutes. (Nogami, K.)

  4. Leading Edge Device Aerodynamic Optimization

    Directory of Open Access Journals (Sweden)

    Marius Gabriel COJOCARU

    2015-12-01

    Full Text Available Leading edge devices are conventionally used as aerodynamic devices that enhance performances during landing and in some cases during takeoff. The need to increase the efficiency of the aircrafts has brought the idea of maintaining as much as possible a laminar flow over the wings. This is possible only when the leading edge of the wings is free from contamination, therefore using the leading edge devices with the additional role of shielding during takeoff. Such a device based on the Krueger flap design is aerodynamically analyzed and optimized. The optimization comprises three steps: first, the positioning of the flap such that the shielding criterion is kept, second, the analysis of the flap size and third, the optimization of the flap shape. The first step is subject of a gradient based optimization process of the position described by two parameters, the position along the line and the deflection angle. For the third step the Adjoint method is used to gain insight on the shape of the Krueger flap that will extend the most the stall limit. All these steps have been numerically performed using Ansys Fluent and the results are presented for the optimized shape in comparison with the baseline configuration.

  5. Implantable biomedical devices on bioresorbable substrates

    Science.gov (United States)

    Rogers, John A; Kim, Dae-Hyeong; Omenetto, Fiorenzo; Kaplan, David L; Litt, Brian; Viventi, Jonathan; Huang, Yonggang; Amsden, Jason

    2014-03-04

    Provided herein are implantable biomedical devices, methods of administering implantable biomedical devices, methods of making implantable biomedical devices, and methods of using implantable biomedical devices to actuate a target tissue or sense a parameter associated with the target tissue in a biological environment. Each implantable biomedical device comprises a bioresorbable substrate, an electronic device having a plurality of inorganic semiconductor components supported by the bioresorbable substrate, and a barrier layer encapsulating at least a portion of the inorganic semiconductor components. Upon contact with a biological environment the bioresorbable substrate is at least partially resorbed, thereby establishing conformal contact between the implantable biomedical device and the target tissue in the biological environment.

  6. Predistortion control device and method, assembly including a predistortion control device

    OpenAIRE

    Kokkeler, André

    2009-01-01

    A predistortion control device (1). The device has a first predistortion control input connectable to a power amplifier output (21); a second predistortion control input (11) connectable to a signal contact of a predistortion device; and a predistortion control output (12) connectable to a control contact of the predistortion device. The predistortion control device (1) further includes a cross-correlator device (110). The cross-correlator device (110) is connected with a first cross-correlat...

  7. Swimming type inspection device and system thereof

    International Nuclear Information System (INIS)

    The present invention provides a swimming type inspection device which can be reduced in the size, easily accessible to each portion of a reactor, and increase the degree of freedom of swimming and visual range, and facilitate visual inspection. The swimming type inspection device comprises two photographing devices, a device which can obtain propelling force by rotation of impellers, two second propelling devices having impellers disposed in perpendicular to the rotating axis of the impellers of the first propelling device, a control device for controlling control signals of first and second propelling devices and driving devices therefor and control image signals of the photographing devices, and transmission section for wireless transmitting of the control signals and the image signals. (N.H.)

  8. Endoluminal occlusion devices: technology update

    Directory of Open Access Journals (Sweden)

    Zander T

    2014-12-01

    Full Text Available Tobias Zander,1 Samantha Medina,1 Guillermo Montes,1 Lourdes Nuñez-Atahualpa,1 Michel Valdes,1 Manuel Maynar1,2 1Endoluminal/Vascular Department, Hospiten Hospital Group, Santa Cruz de Tenerife, 2University of Las Palmas de Gran Canarias, Las Palmas, Canary Island, Spain Abstract: Endoluminal occlusion has been performed since the early beginning of interventional radiology. Over recent decades, major technological advances have improved the techniques used and different devices have been developed for changing conditions. Most of these occlusion devices have been implemented in the vascular territory. Early embolization materials included glass particles, hot contrast, paraffin, fibrin, and tissue fragments such as muscle fibers and blood clots; today, occlusion materials include metallic devices, particles, and liquid materials, which can be indicated for proximal or distal occlusion, high-flow and low-flow situations, and in large-caliber and small-caliber vessels, based on need. Technological progress has led to a decreased size of delivery catheters, and an increase in safety due to release systems that permit the withdrawing and replacement of embolization material. Furthermore, bioactive embolization materials have been developed to increase the efficacy of embolization or the biological effect of medication. Finally, materials have been modified for changing indications. Intravascular stents were initially developed to keep an artery open; however, by adding a covering membrane, these stents can be used to occlude the wall of a vessel or other endoluminal structures. This article gives an overview of the devices most utilized for occlusion of endoluminal structures, as well as their major purpose in the endovascular territory. Keywords: embolization, endovascular treatment, occlusion devices, hemorrhage, aneurysm, fistula

  9. Diabetes Device Interoperability for Improved Diabetes Management

    OpenAIRE

    Silk, Alain D.

    2015-01-01

    Scientific and technological advancements have led to the increasing availability and use of sophisticated devices for diabetes management, with corresponding improvements in public health. These devices are often capable of sharing data with a few other specific devices but are generally not broadly interoperable; they cannot work together with a wide variety of other devices. As a result of limited interoperability, benefits of modern diabetes devices and potential for development of innova...

  10. Integrated Device Control System using Google Maps

    Directory of Open Access Journals (Sweden)

    Takahiro KOITA

    2012-01-01

    Full Text Available This paper proposes an integrated device control system called Control Architecture for Networked Devices in Location Environments (CANDLE, which controls devices with Google Maps. Google Maps provides a global map interface and flexible APIs. The main motivation for this study is to provide a search and control system for physically distributed devices using Google Maps. To achieve this, the requirements of the system are (1 to coordinate device information with map information on Google Maps and (2 all distributed information has to be integrated on one interface. Device information is a set of information to control devices on an interface of Google Maps. CANDLE is an integrated device control system using Google Maps designed to meet these requirements. Using CANDLE, a user can control physically distributed devices through a web browser. In CANDLE, all device information is integrated into one map. CANDLE enables device control, searches, and display of information on distributed devices on an interface of Google Maps through a web browser. By using a web browser, a user can control devices from anywhere even if the devices are distributed globally. Thus, CANDLE is quite useful for distributed device control systems such as security, healthcare, and global monitoring systems.

  11. Integrated optical devices for telecommunications

    Science.gov (United States)

    Qi, Xiaoyuan

    Integrated optical devices have received a lot of interest in recent years. With electronic devices becoming smaller and smaller, semiconductor industries are facing significantly difficult problems. Photonic devices have unique characteristics which can avoid problems in electronic devices and they can achieve better performance. However, the development of integrated optical devices is needed to realize integrated optical circuits in the future. In this thesis, three aspects of integrated optical devices were studied for telecommunication applications. First, integrated isolators were fabricated. Dry etching and wet etching recipes have been developed for the well-known isolator material, yttrium iron garnet (Y3Fe5O 12), and ridge waveguides were patterned into YIG with different configurations. Integrated polarizers based on 2-D YIG photonic crystals (PCs) were also fabricated using a Focused Ion Beam (FIB). Second, an inexpensive method to fabricate 2-D PCs was developed using anodized aluminum oxide (AAO) as an etch mask. An approach to grow nanopores on top of various films/substrates was found. This approach involved growing aluminum films directly onto the substrate of choice, and then anodizing the film electrochemically. The next step was to use reactive ion etching (RIE) to transfer the newly obtained AAO pattern to the underlying films/substrates, and so make PCs, for example in ordered porous Si. The third project was to simulate 1-D and 2-D tunable electro-optic filters for telecommunications. Interfering thin-film structures were studied with Pb(Mg1/3Nb1/3)O3-PbTiO3(PMN-PT) as a 1-D tunable electro-optic layer. Design rules were developed and the performance of these filters was compared with the requirements in dense wavelength division multiplexing (DWDM). 2-D tunable electro-optic filters were also designed based on 2-D photonic crystals and Fabry-Perot structures. The design flow was demonstrated and some results were elaborated. These three

  12. 76 FR 12973 - Neurological Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice

    Science.gov (United States)

    2011-03-09

    ... HUMAN SERVICES Food and Drug Administration Neurological Devices Panel of the Medical Devices Advisory... Medical Devices Advisory Committee. This meeting was announced in the Federal Register of February 7, 2011... meeting of the Neurological Devices Panel of the Medical Devices Advisory Committee would be held on...

  13. 78 FR 14013 - Medical Devices; Exemption From Premarket Notification; Class II Devices; Wheelchair Elevator

    Science.gov (United States)

    2013-03-04

    .../MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/ucm080198.htm or by sending an email request... HUMAN SERVICES Food and Drug Administration 21 CFR Part 890 Medical Devices; Exemption From Premarket... Part 890 Medical devices, Physical medicine devices. Therefore, under the Federal Food, Drug,...

  14. 78 FR 68714 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug

    Science.gov (United States)

    2013-11-15

    ... Device Amendments of 1976 (the 1976 amendments) (Pub. L. 94-295), the Safe Medical Devices Act of 1990... HUMAN SERVICES Food and Drug Administration 21 CFR Part 886 Medical Devices; Ophthalmic Devices... regulation of medical devices intended for human use. Section 513 of the FD&C Act (21 U.S.C....

  15. Hardware device binding and mutual authentication

    Energy Technology Data Exchange (ETDEWEB)

    Hamlet, Jason R; Pierson, Lyndon G

    2014-03-04

    Detection and deterrence of device tampering and subversion by substitution may be achieved by including a cryptographic unit within a computing device for binding multiple hardware devices and mutually authenticating the devices. The cryptographic unit includes a physically unclonable function ("PUF") circuit disposed in or on the hardware device, which generates a binding PUF value. The cryptographic unit uses the binding PUF value during an enrollment phase and subsequent authentication phases. During a subsequent authentication phase, the cryptographic unit uses the binding PUF values of the multiple hardware devices to generate a challenge to send to the other device, and to verify a challenge received from the other device to mutually authenticate the hardware devices.

  16. Electro-refractive photonic device

    Science.gov (United States)

    Zortman, William A.; Watts, Michael R.

    2015-06-09

    The various technologies presented herein relate to phase shifting light to facilitate any of light switching, modulation, amplification, etc. Structures are presented where a second layer is juxtaposed between a first layer and a third layer with respective doping facilitating formation of p-n junctions at the interface between the first layer and the second layer, and between the second layer and the third layer. Application of a bias causes a carrier concentration change to occur at the p-n junctions which causes a shift in the effective refractive index per incremental change in an applied bias voltage. The effective refractive index enhancement can occur in both reverse bias and forward bias. The structure can be incorporated into a waveguide, an optical resonator, a vertical junction device, a horizontal junction device, a Mach-Zehnder interferometer, a tuneable optical filter, etc.

  17. Smoke and pollutant filtering device

    International Nuclear Information System (INIS)

    A smoke and pollutant filtering device comprising a mask having a filter composed of a series of contiguous, serial layers of filtering material. The filter consists of front and rear gas permeable covers, a first filter layer of pressed vegetable matter, a second filter layer comprising a layer of activated charcoal adjacent a layer of aqua filter floss, a third filter comprising a gas permeable cloth situated between layers of pressed vegetable matter, and a fourth filter layer comprising an aqua filter floss. The first through fourth filter layers are sandwiched between the front and rear gas permeable covers. The filtering device is stitched together and mounted within a fireretardant hood shaped to fit over a human head. Elastic bands are included in the hood to maintain the hood snugly about the head when worn

  18. Safety of pulsed electric devices

    International Nuclear Information System (INIS)

    The strength–duration curve for tissue excitation can be modeled by a parallel resistor–capacitor circuit that has a time constant. We tested several short-duration electric generators: five electric fence energizers, the Taser X26 and a high-frequency generator to determine their current-versus-time waveforms. We estimated their safety characteristics using existing IEC and UL standards for electric fence energizers. The current standards are difficult to follow, with cumbersome calculations, and do not explicitly explain the physiological relevance of the calculated parameters. Hence we propose a new standard. The proposed new standard would consist of a physical RC circuit with a certain time constant. The investigator would discharge the device into a passive resistor–capacitor circuit and measure the resulting maximum voltage. If the maximum voltage does not exceed a limit, the device passes the test

  19. Radioactive liquid waste processing device

    International Nuclear Information System (INIS)

    In a radioactive liquid waste processing device comprising a freeze-drying vessel for freezing and then vacuum drying acidic liquid wastes containing radioactive materials and a cold trap condensing steams evaporated in the freeze-drying vessel, a dust collecting electrode of an electric dust collector is disposed in the freeze-drying vessel for capturing fine solid particles and inorganic salts in steams. With such a constitution, upon sublimation of the water content contained in a freezing product of an acidic solution, since fine solid particles and inorganic salts entrained by steams are collected by the dust collecting electrode, radioactive materials entrained by recovered steams are almost eliminated, decontamination efficiency of the liquid waste processing device can be increased. Further, heat for the sublimation can be supplied to the solution-freezing product by a radiation heat caused by electric discharge of the dust collecting electrode, thereby enabling to eliminate the heater which was unnecessary so far. (T.M.)

  20. Waste classifying and separation device

    International Nuclear Information System (INIS)

    A flexible plastic bags containing solid wastes of indefinite shape is broken and the wastes are classified. The bag cutting-portion of the device has an ultrasonic-type or a heater-type cutting means, and the cutting means moves in parallel with the transferring direction of the plastic bags. A classification portion separates and discriminates the plastic bag from the contents and conducts classification while rotating a classification table. Accordingly, the plastic bag containing solids of indefinite shape can be broken and classification can be conducted efficiently and reliably. The device of the present invention has a simple structure which requires small installation space and enables easy maintenance. (T.M.)

  1. Infrared Devices And Techniques (Revision

    Directory of Open Access Journals (Sweden)

    Rogalski A.

    2014-12-01

    Full Text Available The main objective of this paper is to produce an applications-oriented review covering infrared techniques and devices. At the beginning infrared systems fundamentals are presented with emphasis on thermal emission, scene radiation and contrast, cooling techniques, and optics. Special attention is focused on night vision and thermal imaging concepts. Next section concentrates shortly on selected infrared systems and is arranged in order to increase complexity; from image intensifier systems, thermal imaging systems, to space-based systems. In this section are also described active and passive smart weapon seekers. Finally, other important infrared techniques and devices are shortly described, among them being: non-contact thermometers, radiometers, LIDAR, and infrared gas sensors.

  2. Monitoring in IOT enabled devices

    Directory of Open Access Journals (Sweden)

    Udit Gupta

    2015-07-01

    Full Text Available As network size continues to grow exponentially, there has been a proportionate increase in the number of nodes in the corresponding network. With the advent of Internet of things (IOT, it is assumed that many more devices will be connected to the existing network infrastructure. As a result, monitoring is expected to get more complex for administrators as networks tend to become more heterogeneous. Moreover, the addressing for IOTs would be more complex given the scale at which devices will be added to the network and hence monitoring is bound to become an uphill task due to management of larger range of addresses. This paper will throw light on what kind of monitoring mechanisms can be deployed in internet of things (IOTs and their overall effectiveness.

  3. Graphene Superconducting Quantum Interference Device

    Science.gov (United States)

    Girit, Çaǧlar; Bouchiat, Vincent; Naaman, Ofer; Zhang, Yuanbo; Crommie, Michael; Zettl, Alex; Siddiqi, Irfan

    2010-03-01

    Graphene can support Cooper pair transport when contacted with two superconducting electrodes, resulting in the well-known Josephson effect. By depositing aluminum/palladium electrodes in the geometry of a loop onto a single graphene sheet, we fabricate a two junction dc superconducting quantum interference device (SQUID). Not only an the supercurrent in this device be increased by moving the electrostatic gate away from the Dirac point, but it can also be modulated periodically by an applied magnetic field---a potentially powerful probe of electronic transport in graphene. We analyze the magnetic field modulation of the critical current with the asymmetric/inductive SQUID model of Fulton and Dynes and discuss the variation of the fitting parameters with gate voltage.

  4. Erection device for nuclear reactors

    International Nuclear Information System (INIS)

    The assembly and crane unit, respectively, can be used in the erection of the reactor plant proper and in operation jobs. It meets the safety requirements under which cables must be installed in duplicate. The device mainly consists of two cable drums, power transmissions and hoists with one cable each for a certain load. A variable transmission with exchangeable wheel pairs sets various lifting speeds. One of the power transmission can be coupled with the variable transmission by a driving connection with exchangeable shafts of different lengths. A common motor is provided for the hoists. A rigid connection covering various distances connects the two hoists. Moreover, there is a cable equalizer with an adjustment device, e.g., a spring or a lever mechanism, for one of the cables. (DG/RF)

  5. Insertion device calculations with mathematica

    Energy Technology Data Exchange (ETDEWEB)

    Carr, R. [Stanford Synchrotron Radiation Lab., CA (United States); Lidia, S. [Univ. of California, Davis, CA (United States)

    1995-02-01

    The design of accelerator insertion devices such as wigglers and undulators has usually been aided by numerical modeling on digital computers, using code in high level languages like Fortran. In the present era, there are higher level programming environments like IDL{reg_sign}, MatLab{reg_sign}, and Mathematica{reg_sign} in which these calculations may be performed by writing much less code, and in which standard mathematical techniques are very easily used. The authors present a suite of standard insertion device modeling routines in Mathematica to illustrate the new techniques. These routines include a simple way to generate magnetic fields using blocks of CSEM materials, trajectory solutions from the Lorentz force equations for given magnetic fields, Bessel function calculations of radiation for wigglers and undulators and general radiation calculations for undulators.

  6. Reliability evaluation programmable logic devices

    International Nuclear Information System (INIS)

    Programmable Logic Devices (PLD) are widely used as basic building modules in high integrity systems, considering their robust features such as gate density, performance, speed etc. PLDs are used to implement digital design such as bus interface logic, control logic, sequencing logic, glue logic etc. Due to semiconductor evolution, new PLDs with state-of-the-art features are arriving to the market. Since these devices are reliable as per the manufacturer's specification, they were used in the design of safety systems. But due to their reduced market life, the availability of performance data is limited. So evaluating the PLD before deploying in a safety system is very important. This paper presents a survey on the use of PLDs in the nuclear domain and the steps involved in the evaluation of PLD using Quantitative Accelerated Life Testing. (author)

  7. Nanowire structures and electrical devices

    Science.gov (United States)

    Bezryadin, Alexey; Remeika, Mikas

    2010-07-06

    The present invention provides structures and devices comprising conductive segments and conductance constricting segments of a nanowire, such as metallic, superconducting or semiconducting nanowire. The present invention provides structures and devices comprising conductive nanowire segments and conductance constricting nanowire segments having accurately selected phases including crystalline and amorphous states, compositions, morphologies and physical dimensions, including selected cross sectional dimensions, shapes and lengths along the length of a nanowire. Further, the present invention provides methods of processing nanowires capable of patterning a nanowire to form a plurality of conductance constricting segments having selected positions along the length of a nanowire, including conductance constricting segments having reduced cross sectional dimensions and conductance constricting segments comprising one or more insulating materials such as metal oxides.

  8. Conduit purging device and method

    Science.gov (United States)

    Wilks, Michael T. (Inventor)

    2011-01-01

    A device for purging gas comprises a conduit assembly defining an interior volume. The conduit assembly comprises a first conduit portion having an open first end and an open second end and a second conduit portion having an open first end and a closed second end. The open second end of the first conduit portion is disposed proximate to the open first end of the second conduit portion to define a weld region. The device further comprises a supply element supplying a gas to the interior volume at a substantially constant rate and a vent element venting the gas from the interior volume at a rate that maintains the gas in the interior volume within a pressure range suitable to hold a weld bead in the weld region in equilibrium during formation of a weld to join the first conduit portion and the second conduit portion.

  9. Synthetic circuits, devices and modules

    OpenAIRE

    Zhang, Hong; Jiang, Taijiao

    2010-01-01

    The aim of synthetic biology is to design artificial biological systems for novel applications. From an engineering perspective, construction of biological systems of defined functionality in a hierarchical way is fundamental to this emerging field. Here, we highlight some current advances on design of several basic building blocks in synthetic biology including the artificial gene control elements, synthetic circuits and their assemblies into devices and modules. Such engineered basic buildi...

  10. Microfluidic device, and related methods

    Science.gov (United States)

    Wong, Eric W. (Inventor)

    2010-01-01

    A method of making a microfluidic device is provided. The method features patterning a permeable wall on a substrate, and surrounding the permeable wall with a solid, non-permeable boundary structure to establish a microfluidic channel having a cross-sectional dimension less than 5,000 microns and a cross-sectional area at least partially filled with the permeable wall so that fluid flowing through the microfluidic channel at least partially passes through the permeable wall.

  11. Capacitor ageing in electronic devices

    OpenAIRE

    Richard B. N. Vital; Tatiane M. Vital

    2015-01-01

    The moment when an electronic component doesn’t work like requirements, previously established is a task that need to be considered since began of a system design. However, the use of different technologies, operating under several environmental conditions, makes a component choice a complex step in system design. This paper analyzes the effects that ageing phenomenon of capacitors may introduce in electronic devices operation. For this reason, reliability concepts, processes and ...

  12. Endoluminal occlusion devices: technology update

    OpenAIRE

    Zander, Tobias

    2014-01-01

    Tobias Zander,1 Samantha Medina,1 Guillermo Montes,1 Lourdes Nuñez-Atahualpa,1 Michel Valdes,1 Manuel Maynar1,2 1Endoluminal/Vascular Department, Hospiten Hospital Group, Santa Cruz de Tenerife, 2University of Las Palmas de Gran Canarias, Las Palmas, Canary Island, Spain Abstract: Endoluminal occlusion has been performed since the early beginning of interventional radiology. Over recent decades, major technological advances have improved the techniques used and different devices h...

  13. Endoluminal occlusion devices: technology update

    OpenAIRE

    Zander T.; Medina S; Montes G; Nuñez-Atahualpa L; Valdes M; Maynar M

    2014-01-01

    Tobias Zander,1 Samantha Medina,1 Guillermo Montes,1 Lourdes Nuñez-Atahualpa,1 Michel Valdes,1 Manuel Maynar1,2 1Endoluminal/Vascular Department, Hospiten Hospital Group, Santa Cruz de Tenerife, 2University of Las Palmas de Gran Canarias, Las Palmas, Canary Island, Spain Abstract: Endoluminal occlusion has been performed since the early beginning of interventional radiology. Over recent decades, major technological advances have improved the techniques used and different devices have ...

  14. Coherent manipulation of mesoscopic devices

    OpenAIRE

    Lucignano, Procolo

    2005-01-01

    The manipulation of quantum states of solid state coherent devices is the central goal of this thesis. The problems studied concern both the superconductors and the semiconductors physics. They are reported in three chapters; each chapter has its own appendixes, a bibliography, and a detailed discussion in the end, so that the reader could read whatever chapter independently of the others. In what follows I briefly summarize the topics developed in this work describing them as they appear ...

  15. Fusion engineering device design description

    International Nuclear Information System (INIS)

    The US Magnetic Fusion Engineering Act of 1980 calls for the operation of a Fusion Engineering Device (FED) by 1990. It is the intent of the Act that the FED, in combination with other testing facilities, will establish the engineering feasibility of magnetic fusion energy. During 1981, the Fusion Engineering Design Center (FEDC), under the guidance of a Technical Management Board (TMB), developed a baseline design for the FED. This design is summarized herein

  16. Portable vacuum object handling device

    Science.gov (United States)

    Anderson, G.H.

    1983-08-09

    The disclosure relates to a portable device adapted to handle objects which are not to be touched by hand. A piston and bore wall form a vacuum chamber communicating with an adaptor sealably engageable with an object to be lifted. The piston is manually moved and set to establish vacuum. A valve is manually actuatable to apply the vacuum to lift the object. 1 fig.

  17. Fusion Engineering Device design description

    International Nuclear Information System (INIS)

    The US Magnetic Fusion Engineering Act of 1980 calls for the operation of a Fusion Engineering Device (FED) by 1990. It is the intent of the Act that the FED, in combination with other testing facilities, will establish the engineering feasibility of magnetic fusion energy. During 1981, the Fusion Engineering Design Center (FEDC), under the guidance of a Technical Management Board (TMB), developed a baseline design for the FED. This design is summarized herein

  18. A Disease and its Device

    OpenAIRE

    Turney, John

    2013-01-01

    ABSTRACTThe University of ManchesterJohn Harry TURNEYDoctor of Philosophy (PhD)A Disease and its Device: The Introduction of Dialysis for Acute Renal Failure, with particular reference to Leeds, UK, c.1945 – c.20002013 Dialysis was the first instance of the possibility of replacement of organ function by a machine. Although now an established medical activity, it was only slowly adopted. The early machines were laboriously difficult in practice and appeared to have no clear indication for use...

  19. Thermal transport in mesoscopic devices

    OpenAIRE

    Ruokola, Tomi

    2012-01-01

    New mechanisms for controlling heat flow and for converting heat to work in small-scale solid-state systems are highly desirable, particularly when considering the rapid miniaturization and ever-increasing power densities of electronic devices. Mesoscopic structures, being much larger than individual atoms but still small enough to exhibit some quantum-mechanical features, offer a versatile platform for studying thermal phenomena at reduced length scales. We perform a theoretical study of ...

  20. Infrared Devices And Techniques (Revision)

    OpenAIRE

    Rogalski A.; Chrzanowski K.

    2014-01-01

    The main objective of this paper is to produce an applications-oriented review covering infrared techniques and devices. At the beginning infrared systems fundamentals are presented with emphasis on thermal emission, scene radiation and contrast, cooling techniques, and optics. Special attention is focused on night vision and thermal imaging concepts. Next section concentrates shortly on selected infrared systems and is arranged in order to increase complexity; from image intensifier systems,...

  1. Infrared detector device inspection system

    Energy Technology Data Exchange (ETDEWEB)

    Soehnel, Grant; Bender, Daniel A.

    2016-08-09

    Methods and apparatuses for identifying carrier lifetimes are disclosed herein. In a general embodiment, a beam of light is sent to a group of locations on a material for an optical device. Photons emitted from the material are detected at each of the group of locations. A carrier lifetime is identified for each of the group of locations based on the photons detected from each of the group of locations.

  2. Nanoscale Electrothermal Energy Conversion Devices

    OpenAIRE

    Bahk, Je-Hyeong; Ezzahri, Younes; Yazawa, Kazuaki; Vermeersch, Bjorn; Pernot, Gilles; Shakouri, Ali

    2012-01-01

    Energy consumption in our society is increasing rapidly. A significant fraction of the energy is lost in the form of heat. In this talk we introduce thermoelectric devices that allow direct conversion of heat into electricity. Some new physical concepts and nanostructures make it possible to modify the trade-offs between the bulk electrothermal material properties through the changes in the density of states, scattering rates, and interface effects on the electron and phonon transport. The po...

  3. New Devices for Electret Measurement

    OpenAIRE

    ROMANIUC Ilie

    2013-01-01

    Green energy research have increased in recent decades and interest in unconventional energy production systems is becoming more pronounced. Such unconventional energy generation system is alsobased on electret generator. The electret, is a dielectric material that has a quasi-permanent electric charge. This paper, provides a brief history of the Carnauba wax electret, will be described the process of electret making and will be presented two devices formeasuring the carnauba wax electrets, o...

  4. Evaluating Readability on Mobile Devices

    OpenAIRE

    Öquist, Gustav

    2006-01-01

    The thesis presents findings from five readability studies performed on mobile devices. The dynamic Rapid Serial Visual Presentation (RSVP) format has been enhanced with regard to linguistic adaptation and segmentation as well as eye movement modeling. The novel formats have been evaluated against other common presentation formats including Paging, Scrolling, and Leading in latin-square balanced repeated-measurement studies with 12-16 subjects. Apart from monitoring Reading speed, Comprehensi...

  5. Game Design for Mobile Devices

    OpenAIRE

    ODSTAM, MÅNS; STJ ERNDAL, A N D R E A S

    2013-01-01

    In the last few years there has been an incredible rise in the amount of game applications available for the latest generation of mobile platforms. An increasing amount of developers and companies are starting to invest more heavily in producing for this growing market. This report investigates some of the challenges faced when developing these games, with the focus on the genre turn based strategy games. The main areas that are explored are the time of a session with the device, the touchscr...

  6. Article removal device for glovebox

    Science.gov (United States)

    Guyer, R.H.; Leebl, R.G.

    1973-12-01

    An article removal device for a glovebox is described comprising a conduit extending through a glovebox wall which may be closed by a plug within the glovebox, and a fire-resistant container closing the outer end of the conduit and housing a removable container for receiving pyrophoric or otherwise hazardous material without disturbing the interior environment of the glovebox or adversely affecting the environment outside of the glovebox. (Official Gazette)

  7. Encapsulant materials and associated devices

    Energy Technology Data Exchange (ETDEWEB)

    Kempe, Michael D (Littleton, CO); Thapa, Prem (Lima, OH)

    2011-03-08

    Compositions suitable for use as encapsulants are described. The inventive compositions include a high molecular weight polymeric material, a curing agent, an inorganic compound, and a coupling agent. Optional elements include adhesion promoting agents, colorants, antioxidants, and UV absorbers. The compositions have desirable diffusivity properties, making them suitable for use in devices in which a substantial blocking of moisture ingress is desired, such as photovoltaic (PV) modules.

  8. Encapsulant materials and associated devices

    Energy Technology Data Exchange (ETDEWEB)

    Kempe, Michael D (Littleton, CO); Thapa, Prem (Lima, OH)

    2012-05-22

    Compositions suitable for use as encapsulants are described. The inventive compositions include a high molecular weight polymeric material, a curing agent, an inorganic compound, and a coupling agent. Optional elements include adhesion promoting agents, colorants, antioxidants, and UV absorbers. The compositions have desirable diffusivity properties, making them suitable for use in devices in which a substantial blocking of moisture ingress is desired, such as photovoltaic (PV) modules.

  9. Risk Perceptions for Wearable Devices

    OpenAIRE

    Lee, Linda; Egelman, Serge; Lee, Joong Hwa; Wagner, David

    2015-01-01

    Wearable devices, or "wearables," bring great benefits but also potential risks that could expose users' activities with- out their awareness or consent. In this paper, we report findings from the first large-scale survey conducted to investigate user security and privacy concerns regarding wearables. We surveyed 1,782 Internet users in order to identify risks that are particularly concerning to them; these risks are inspired by the sensor inputs and applications of popular wearable technolog...

  10. A nanophotonic solar thermophotovoltaic device

    Science.gov (United States)

    Lenert, Andrej; Bierman, David M.; Nam, Youngsuk; Chan, Walker R.; Celanović, Ivan; Soljačić, Marin; Wang, Evelyn N.

    2014-02-01

    The most common approaches to generating power from sunlight are either photovoltaic, in which sunlight directly excites electron-hole pairs in a semiconductor, or solar-thermal, in which sunlight drives a mechanical heat engine. Photovoltaic power generation is intermittent and typically only exploits a portion of the solar spectrum efficiently, whereas the intrinsic irreversibilities of small heat engines make the solar-thermal approach best suited for utility-scale power plants. There is, therefore, an increasing need for hybrid technologies for solar power generation. By converting sunlight into thermal emission tuned to energies directly above the photovoltaic bandgap using a hot absorber-emitter, solar thermophotovoltaics promise to leverage the benefits of both approaches: high efficiency, by harnessing the entire solar spectrum; scalability and compactness, because of their solid-state nature; and dispatchablility, owing to the ability to store energy using thermal or chemical means. However, efficient collection of sunlight in the absorber and spectral control in the emitter are particularly challenging at high operating temperatures. This drawback has limited previous experimental demonstrations of this approach to conversion efficiencies around or below 1% (refs 9, 10, 11). Here, we report on a full solar thermophotovoltaic device, which, thanks to the nanophotonic properties of the absorber-emitter surface, reaches experimental efficiencies of 3.2%. The device integrates a multiwalled carbon nanotube absorber and a one-dimensional Si/SiO2 photonic-crystal emitter on the same substrate, with the absorber-emitter areas optimized to tune the energy balance of the device. Our device is planar and compact and could become a viable option for high-performance solar thermophotovoltaic energy conversion.

  11. High frequency carbon nanotube devices

    Science.gov (United States)

    Goffman, M. F.; Chimot, N.; Mile, E.; Monteverde, M. C.; Bourgoin, J.-P.; Derycke, V.

    2008-08-01

    We investigate high frequency electrical and mechanical performances of carbon nanotube based devices. Using configurations with multiple single-wall nanotubes in parallel, we show that HF nanotube transistors with intrinsic cut-off frequencies as high as 30 GHz can be obtained on rigid substrates. Adapting our process to plastic substrates, we also obtained highly flexible HF transistors showing constant transconductances up to at least 6 GHz, as-measured cut-off frequencies as high as 1 GHz (5-8 GHz after de-embedding) and stable DC performances upon bending. We probed electromechanical properties of individual suspended carbon multiwall nanotubes by using a modified AFM. DC deflection measurements on different devices are in agreement with a continuum model prediction and consistent with a Young's modulus of 0.4 TPa. Preliminary HF measurements on a doubly clamped device showed a resonant frequency of 200MHz consistent with a Young's modulus of 0.43 TPa. This implies that built-in mechanical stress in the case of MWNTs is negligeable.

  12. Numerical Modeling of Nanoelectronic Devices

    Science.gov (United States)

    Klimeck, Gerhard; Oyafuso, Fabiano; Bowen, R. Chris; Boykin, Timothy

    2003-01-01

    Nanoelectronic Modeling 3-D (NEMO 3-D) is a computer program for numerical modeling of the electronic structure properties of a semiconductor device that is embodied in a crystal containing as many as 16 million atoms in an arbitrary configuration and that has overall dimensions of the order of tens of nanometers. The underlying mathematical model represents the quantummechanical behavior of the device resolved to the atomistic level of granularity. The system of electrons in the device is represented by a sparse Hamiltonian matrix that contains hundreds of millions of terms. NEMO 3-D solves the matrix equation on a Beowulf-class cluster computer, by use of a parallel-processing matrix vector multiplication algorithm coupled to a Lanczos and/or Rayleigh-Ritz algorithm that solves for eigenvalues. In a recent update of NEMO 3-D, a new strain treatment, parameterized for bulk material properties of GaAs and InAs, was developed for two tight-binding submodels. The utility of the NEMO 3-D was demonstrated in an atomistic analysis of the effects of disorder in alloys and, in particular, in bulk In(x)Ga(l-x)As and in In0.6Ga0.4As quantum dots.

  13. Pneumatic servo-controlled fracture resistance measuring device (PSFM-device) and contact electric resistance measuring device (CER device)

    International Nuclear Information System (INIS)

    A pneumatic servo-controlled fracture resistance measuring device can be used to test small pre cracked three point bend specimens in high temperature aqueous solutions. As the moving parts that penetrate the pressure boundary are not needed, the friction force at the sealing element location is avoided. Therefore the load control is more accurate than with the conventional servo-hydraulic devices. This enables testing of small size samples which is an advantage e.g. when testing irradiated materials and especially in determining environmentally assisted crack growth rate of structural materials. Furthermore, the new design enables simultaneous testing of several samples, which helps in producing of statistically more reliable data in a more economical way. The newly developed measuring device was used to determine fracture resistance curves for sensitized AISI 304 stainless steel, AISI 316 stainless steel and Inconel weld materials. The test environment was BWR (Boiling Water Reactor) coolant in a recirculation loop and the test type was constant displacement rate test (rising load) with displacement rates of 1.2 10-5 mm/min and 1.2 10-6 mm/min. The momentary crack growth during the tests was measured with the PD (potential drop) technique. The preliminary tests with pneumatically powered CER (Contact Electric Resistance) equipment is presented. The main parts and preliminary test results of pneumatically powered CER measuring are presented. The equipment was tested in air at room temperature and under typical BWR environments (author) (ml)

  14. From MEMRISTOR to MEMImpedance device

    Science.gov (United States)

    Wakrim, T.; Vallée, C.; Gonon, P.; Mannequin, C.; Sylvestre, A.

    2016-02-01

    The behavior of the capacitance switching of HfO2 Resistive non-volatile Memories is investigated in view of realizing a MEMImpedance (MEM-Z) device. In such a Metal Insulator Metal structure, the impedance value can be tuned by the adjustment of both resistance and capacitance values. We observe a strong variation of capacitance from positive to negative values in a single layer Metal Insulator Metal device made of HfO2 deposited by Atomic Layer Deposition, but unfortunately no memory effect is observed. However, in the case of a two layer structure, a device has been obtained with a memory effect where both resistance and capacitance values can be tuned simultaneously, with a variation of capacitance down to negative values to get an inductive behavior. Negative capacitance values are observed for voltage values near SET voltage. A schematic model based on shaped oxygen vacancy density is proposed to account for this capacitance variation. The oxygen vacancies can be either isolated or connected in the bulk of the oxide.

  15. Cotton-based diagnostic devices.

    Science.gov (United States)

    Lin, Shang-Chi; Hsu, Min-Yen; Kuan, Chen-Meng; Wang, Hsi-Kai; Chang, Chia-Ling; Tseng, Fan-Gang; Cheng, Chao-Min

    2014-01-01

    A good diagnostic procedure avoids wasting medical resources, is easy to use, resists contamination, and provides accurate information quickly to allow for rapid follow-up therapies. We developed a novel diagnostic procedure using a "cotton-based diagnostic device" capable of real-time detection, i.e., in vitro diagnostics (IVD), which avoids reagent contamination problems common to existing biomedical devices and achieves the abovementioned goals of economy, efficiency, ease of use, and speed. Our research reinforces the advantages of an easy-to-use, highly accurate diagnostic device created from an inexpensive and readily available U.S. FDA-approved material (i.e., cotton as flow channel and chromatography paper as reaction zone) that adopts a standard calibration curve method in a buffer system (i.e., nitrite, BSA, urobilinogen and uric acid assays) to accurately obtain semi-quantitative information and limit the cross-contamination common to multiple-use tools. Our system, which specifically targets urinalysis diagnostics and employs a multiple biomarker approach, requires no electricity, no professional training, and is exceptionally portable for use in remote or home settings. This could be particularly useful in less industrialized areas. PMID:25393975

  16. Virtual cathode microwave devices -- Basics

    Energy Technology Data Exchange (ETDEWEB)

    Thode, L.E.; Snell, C.M.

    1991-01-01

    Unlike a conventional microwave tube, a virtual-cathode device operates above the space-charge limit where the depth of the space-charge potential can cause electron reflection. The region associated with this electron reflection is referred to as a virtual cathode. Microwaves can be generated through oscillations in the position of the virtual cathode and through the bunching of electrons trapped in a potential well between the real and virtual cathodes. These two mechanisms are competitive. There are three basic classes of virtual cathode devices: (1) reflex triode; (2) reditron and side-shoot vircator; and (3) reflex diode or vircator. The reflex diode is the highest power virtual-cathode device. For the reflex diode the energy exchange between the beam and electromagnetic wave occurs in both the axial and radial directions. In some designs the oscillating-virtual-cathode frequency exceeds the reflexing-electron frequency exceeds the oscillating-virtual-cathode frequency. For the flex diode a periodic disruption in magnetic insulation can modulate the high- frequency microwave power. Overall, particle-in-cell simulation predictions and axial reflex diode experiments are in good agreement. Although frequency stability and phase locking of the reflex diode have been demonstrated, little progress has been made in efficiency enhancement. 58 refs., 11 figs.

  17. Virtual cathode microwave devices: Basics

    Science.gov (United States)

    Thode, L. E.; Snell, C. M.

    Unlike a conventional microwave tube, a virtual-cathode device operates above the space-charge limit where the depth of the space-charge potential can cause electron reflection. The region associated with this electron reflection is referred to as a virtual cathode. Microwaves can be generated through oscillations in the position of the virtual cathode and through the bunching of electrons trapped in a potential well between the real and virtual cathodes. These two mechanisms are competitive. There are three basic classes of virtual cathode devices: (1) reflex triode; (2) reditron and side-shoot vircator; and (3) reflex diode or vircator. The reflex diode is the highest power virtual-cathode device. For the reflex diode the energy exchange between the beam and electromagnetic wave occurs in both the axial and radial directions. In some designs the oscillating virtual-cathode frequency exceeds the reflexing-electron frequency while in other designs the reflexing-electron frequency exceeds the oscillating virtual-cathode frequency. For the flex diode, a periodic disruption in magnetic insulation can modulate the high-frequency microwave power. Overall, particle-in-cell simulation predictions and axial reflex diode experiments are in good agreement. Although frequency stability and phase locking of the reflex diode have been demonstrated, little progress has been made in efficiency enhancement.

  18. Metamaterial mirrors in optoelectronic devices

    KAUST Repository

    Esfandyarpour, Majid

    2014-06-22

    The phase reversal that occurs when light is reflected from a metallic mirror produces a standing wave with reduced intensity near the reflective surface. This effect is highly undesirable in optoelectronic devices that use metal films as both electrical contacts and optical mirrors, because it dictates a minimum spacing between the metal and the underlying active semiconductor layers, therefore posing a fundamental limit to the overall thickness of the device. Here, we show that this challenge can be circumvented by using a metamaterial mirror whose reflection phase is tunable from that of a perfect electric mirror († = €) to that of a perfect magnetic mirror († = 0). This tunability in reflection phase can also be exploited to optimize the standing wave profile in planar devices to maximize light-matter interaction. Specifically, we show that light absorption and photocurrent generation in a sub-100 nm active semiconductor layer of a model solar cell can be enhanced by ∼20% over a broad spectral band. © 2014 Macmillan Publishers Limited.

  19. From MEMRISTOR to MEMImpedance device

    Energy Technology Data Exchange (ETDEWEB)

    Wakrim, T. [Univ. Grenoble Alpes, LTM (CEA-LETI/Minatec), 38000 Grenoble (France); Univ. Grenoble Alpes, G2Elab, F-38000 Grenoble (France); Vallée, C., E-mail: christophe.vallee@cea.fr; Gonon, P.; Mannequin, C. [Univ. Grenoble Alpes, LTM (CEA-LETI/Minatec), 38000 Grenoble (France); Sylvestre, A. [Univ. Grenoble Alpes, G2Elab, F-38000 Grenoble (France)

    2016-02-01

    The behavior of the capacitance switching of HfO{sub 2} Resistive non-volatile Memories is investigated in view of realizing a MEMImpedance (MEM-Z) device. In such a Metal Insulator Metal structure, the impedance value can be tuned by the adjustment of both resistance and capacitance values. We observe a strong variation of capacitance from positive to negative values in a single layer Metal Insulator Metal device made of HfO{sub 2} deposited by Atomic Layer Deposition, but unfortunately no memory effect is observed. However, in the case of a two layer structure, a device has been obtained with a memory effect where both resistance and capacitance values can be tuned simultaneously, with a variation of capacitance down to negative values to get an inductive behavior. Negative capacitance values are observed for voltage values near SET voltage. A schematic model based on shaped oxygen vacancy density is proposed to account for this capacitance variation. The oxygen vacancies can be either isolated or connected in the bulk of the oxide.

  20. Mix bed type desalting device

    International Nuclear Information System (INIS)

    The present invention provides a condensate desalting device of a BWR type reactor capable of preventing degradation of ion exchange resins by water containing oxidative materials such as hydrogen peroxide thereby keeping reactor water at high purity. Namely, a mixed bed type desalting device comprises a desalting tower for removing impurities in water by ion exchange resins and a regeneration device for cleaning/regenerating the ion exchange resins. Means for loading iron cruds into water is disposed in the desalting tower. With such a constitution, oxidative materials such as hydrogen peroxide react with the iron cruds thereby enabling to suppress oxidative reaction during ion exchange. Since passage or cleaning/regeneration of water is conducted while loading the iron cruds between ion exchange resin particles and on the surface layer of an ion exchange resin layer by using the above-mentioned reaction, degradation of ion exchange performance of the ion exchange resins by hydrogen peroxide can be prevented upon condensate cleaning operation or resin cleaning/regeneration. As a result, degradation of quality of reactor water can be suppressed. (I.S.)

  1. Learning from adverse incidents involving medical devices.

    Science.gov (United States)

    Amoore, John; Ingram, Paula

    While an adverse event involving a medical device is often ascribed to either user error or device failure, the causes are typically multifactorial. A number of incidents involving medical devices are explored using this approach to investigate the various causes of the incident and the protective barriers that minimised or prevented adverse consequences. User factors, including mistakes, omissions and lack of training, conspired with background factors--device controls and device design, storage conditions, hidden device damage and physical layout of equipment when in use--to cause the adverse events. Protective barriers that prevented or minimised the consequences included staff vigilance, operating procedures and alarms. PMID:12715578

  2. 77 FR 16925 - Medical Devices; Neurological Devices; Classification of the Near Infrared Brain Hematoma Detector

    Science.gov (United States)

    2012-03-23

    ... Electrical safety and electromagnetic compatibility (EMC). Interference with other devices........ Electrical... HUMAN SERVICES Food and Drug Administration 21 CFR Part 882 Medical Devices; Neurological Devices... individually or cumulatively have a significant effect on the human environment. Therefore, neither...

  3. 77 FR 25183 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2012-04-27

    ... HUMAN SERVICES Food and Drug Administration Circulatory System Devices Panel of the Medical Devices... the Medical Devices Advisory Committee. General Function of the Committee: To provide advice and... Commissioner for Special Medical Programs. BILLING CODE 4160-01-P...

  4. 78 FR 34669 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2013-06-10

    ... COMMISSION Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data..., California (``Apple''), from importing wireless communication devices, portable music and data processing... Telecommunications America, LLC of Richardson, Texas (collectively, ``Samsung''). 76 FR 45860 (Aug. 1, 2011)....

  5. Fast response liquid crystal devices

    Science.gov (United States)

    Wu, Yung-Hsun

    Liquid crystal (LC) has been widely used for displays, spatial light modulators, variable optical attenuators (VOAs) and other tunable photonic devices. The response time of these devices is mainly determined by the employed liquid crystal material. The response time of a LC device depends on the visco-elastic coefficient (gamma1/K11), LC cell gap (d), and applied voltage. Hence, low visco-elastic coefficient LC materials and thinner cell gap are favorable for reducing the response time. However, low visco-elastic coefficient LCs are usually associated with a low birefringence because of shorter molecular conjugation. For display applications, such as LCD TVs, low birefringence (Deltanthick cell gap which, in turn, increases the response time. How to obtain fast response for the LC devices is a fundamentally important and technically challenging task. In this dissertation, we investigate several methods to improve liquid crystal response time, for examples, using dual-frequency liquid crystals, polymer stabilized liquid crystals, and sheared polymer network liquid crystals. We discover a new class of material, denoted as sheared polymer network liquid crystal (SPNLC) which exhibits a submillisecond response time. Moreover, this response time is insensitive to the LC cell gap. This is the first LC device exhibiting such an interesting property. Chapters 1 and 2 describe the motivation and background of this dissertation. From chapter 3 to chapter 6, dual-frequency liquid crystals and polymer network methods are demonstrated as examples for the variable optical attenuators. Variable optical attenuator (VOA) is a key component in optical communications. Especially, the sheared PNLC VOA shows the best result; its dynamic range reaches 43 dB while the response time is in the submillisecond range at 1550 nm wavelength, which is 50 times faster than the commercial LC-based VOA. In Chapter 7, we report a new device called axially-symmetric sheared polymer network liquid

  6. Nonisothermal device simulation using the 2-D numerical process/device simulator TRENDY and application to SOI-devices

    NARCIS (Netherlands)

    Wolbert, Philip B.M.; Wachutka, Gerhard K.M.; Krabbenborg, Benno H.; Mouthaan, Ton J.

    1994-01-01

    The electrical characteristics of modern VLSI and ULSI device structures may be significantly altered by self-heating effects. The device modeling of such structures demands the simultaneous simulation of both the electrical and the thermal device behavior and their mutual interaction. Although, at

  7. 49 CFR 179.220-17 - Gauging devices, top loading and unloading devices, venting and air inlet devices.

    Science.gov (United States)

    2010-10-01

    ... inlet devices. (a) When installed, each device must be of approved design which will prevent interchange.... (c) Inner container may be equipped with a vacuum relief valve of approved design. Protective housing is not required. (d) When a gauging device is required in § 179.221-1, an outage scale...

  8. Release strategies for making transferable semiconductor structures, devices and device components

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, John A.; Nuzzo, Ralph G.; Meitl, Matthew; Ko, Heung Cho; Yoon, Jongseung; Menard, Etienne; Baca, Alfred J.

    2016-05-24

    Provided are methods for making a device or device component by providing a multi layer structure having a plurality of functional layers and a plurality of release layers and releasing the functional layers from the multilayer structure by separating one or more of the release layers to generate a plurality of transferable structures. The transferable structures are printed onto a device substrate or device component supported by a device substrate. The methods and systems provide means for making high-quality and low-cost photovoltaic devices, transferable semiconductor structures, (opto-)electronic devices and device components.

  9. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard;

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  10. Making Medical Devices Safer at Home

    Science.gov (United States)

    ... For Consumers Home For Consumers Consumer Updates Making Medical Devices Safer at Home Share Tweet Linkedin Pin it ... Tips for Consumers Patients and consumers are using medical devices more often at home—not just in health ...

  11. Optical Fiber Devices in WDM Networks

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Crystal optics and fiber grating technology are two of the most important optical fiber device technologies. In this paper, we report several new devices developed in Accelink for WDM networks application.

  12. Magnetically driven medical devices: a review.

    Science.gov (United States)

    Sliker, Levin; Ciuti, Gastone; Rentschler, Mark; Menciassi, Arianna

    2015-01-01

    A widely accepted definition of a medical device is an instrument or apparatus that is used to diagnose, prevent or treat disease. Medical devices take a broad range of forms and utilize various methods to operate, such as physical, mechanical or thermal. Of particular interest in this paper are the medical devices that utilize magnetic field sources to operate. The exploitation of magnetic fields to operate or drive medical devices has become increasingly popular due to interesting characteristics of magnetic fields that are not offered by other phenomena, such as mechanical contact, hydrodynamics and thermodynamics. Today, there is a wide range of magnetically driven medical devices purposed for different anatomical regions of the body. A review of these devices is presented and organized into two groups: permanent magnetically driven devices and electromagnetically driven devices. Within each category, the discussion will be further segregated into anatomical regions (e.g., gastrointestinal, ocular, abdominal, thoracic, etc.). PMID:26295303

  13. Visual inspection device for reactor inside

    International Nuclear Information System (INIS)

    The present invention concerns a submerged type inspection device for visually inspecting structures and equipments such as a reactor pressure vessel, fuel pool, etc. That is, this device comprises a vehicle which moves in the reactor structure, a control device for controlling the water vehicle in water and a cable which connects both of them. The water vehicle comprises a TV camera with focus control function and tilting function, a depth gauge, an angular velocity gauge, a submerged illumination light, a position fixing device and a plurality of propulsion devices. The water vehicle of the visual inspection device for the inside of the reactor is put into the reactor structure filled with water. Each propulsion device is controlled by the control device and water vehicle is brought closer to an object. Then, pictures are taken by the TV and with the submerged illumination light, which are displayed on a monitor. (I.S.)

  14. Field Errors in Hybrid Insertion Devices

    OpenAIRE

    Schlueter, R.D.

    1995-01-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed.

  15. Field errors in hybrid insertion devices

    Energy Technology Data Exchange (ETDEWEB)

    Schlueter, R.D. [Lawrence Berkeley Lab., CA (United States)

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed.

  16. Night Vision Device and Cockpit Displays

    Data.gov (United States)

    Federal Laboratory Consortium — The Night Vision Device and Cockpit Display labevaluates night vision devices and certifies them for use in the fleet. Lab functions supported include: Analysis of...

  17. Wireless Device-to-Device Communications with Distributed Caching

    CERN Document Server

    Golrezaei, Negin; Molisch, Andreas F

    2012-01-01

    We introduce a novel wireless device-to-device (D2D) collaboration architecture that exploits distributed storage of popular content to enable frequency reuse. We identify a fundamental conflict between collaboration distance and interference and show how to optimize the transmission power to maximize frequency reuse. Our analysis depends on the user content request statistics which are modeled by a Zipf distribution. Our main result is a closed form expression of the optimal collaboration distance as a function of the content reuse distribution parameters. We show that if the Zipf exponent of the content reuse distribution is greater than 1, it is possible to have a number of D2D interference-free collaboration pairs that scales linearly in the number of nodes. If the Zipf exponent is smaller than 1, we identify the best possible scaling in the number of D2D collaborating links. Surprisingly, a very simple distributed caching policy achieves the optimal scaling behavior and therefore there is no need to cent...

  18. Apple and Samsung Mobile Devices Comparison

    OpenAIRE

    Bureš, Jakub

    2013-01-01

    Bachelor thesis presents a comparison of mobile devices, Apple and Samsung, in particular the characteristics of the individual companies and the historical development of their mobile devices. It is focused on a comparison of selected mobile devices and finally discusses the major patent wars waged between the two companies. At the same time bachelor's thesis in his research points to the specific preferences of users of mobile devices.

  19. Fabrication of integrated metallic MEMS devices

    DEFF Research Database (Denmark)

    Yalcinkaya, Arda Deniz; Ravnkilde, Jan Tue; Hansen, Ole

    2002-01-01

    A simple and complementary metal oxide semiconductor (CMOS) compatible fabrication technique for microelectromechanical (MEMS) devices is presented. The fabrication technology makes use of electroplated metal layers. Among the fabricated devices, high quality factor microresonators are characteri......A simple and complementary metal oxide semiconductor (CMOS) compatible fabrication technique for microelectromechanical (MEMS) devices is presented. The fabrication technology makes use of electroplated metal layers. Among the fabricated devices, high quality factor microresonators are...

  20. Designing Climbing Guides for Mobile Devices

    OpenAIRE

    2011-01-01

    Due to the rapid technological development of mobile devices in recent years, cell phones now support a far broader range of usability than simply calling and sending text messages. Technologies that were previously unique to numerous individual handheld devices – such as cameras, video recorders, geographic location devices, touch screens, altimeters and Internet – are now converging and becoming commonplace to one single device. This is providing a foundation for new ways of combining media...

  1. Study on Braille Input Output Devices

    OpenAIRE

    S.Padmavathi; S. Saradha

    2014-01-01

    This document is about the Braille devices .there nearly 45 to 50 million are many people in the world who are blind and more than 269 who visually impaired. before the inversion of Braille device blind people cannot able to read or gain knowledge through reading Louis Braille is the person who invented the device called Braille which became popular by the usage ,nowadays there are many devices arrived in this world to solve the visually impaired peoples problem not only we ca...

  2. Medical devices regulations, standards and practices

    CERN Document Server

    Ramakrishna, Seeram; Wang, Charlene

    2015-01-01

    Medical Devices and Regulations: Standards and Practices will shed light on the importance of regulations and standards among all stakeholders, bioengineering designers, biomaterial scientists and researchers to enable development of future medical devices. Based on the authors' practical experience, this book provides a concise, practical guide on key issues and processes in developing new medical devices to meet international regulatory requirements and standards. Provides readers with a global perspective on medical device regulationsConcise and comprehensive information on how to desig

  3. Structure and application of galvanomagnetic devices

    CERN Document Server

    Weiss, H

    1969-01-01

    International Series of Monographs on Semiconductors, Volume 8: Structure and Application of Galvanomagnetic Devices focuses on the composition, reactions, transformations, and applications of galvanomagnetic devices. The book first ponders on basic physical concepts, design and fabrication of galvanomagnetic devices, and properties of galvanomagnetic devices. Discussions focus on changes in electrical properties on irradiation with high-energy particles, magnetoresistor field-plate, Hall generator, preparation of semiconductor films by vacuum deposition, structure of field-plate magnetoresist

  4. Cross-platform Development for Wearable Devices

    OpenAIRE

    Beck-Norén, Gustav

    2015-01-01

    The market for wearable devices is continuously growing and has seen an in- crease in interest and demand this past year, specifically smartwatch devices. With several big players entering and trying to take place in the market the number of devices and platforms grow. This leads to device and software fragmentation like the one seen in the world of smartphones. In this paper I discuss and compare the two smartwatch platforms Android Wear and Apple Watch in terms of possibilities, limitations...

  5. Device-aware Adaptation of Websites

    OpenAIRE

    Barsomo, Milad; Hurtig, Mats

    2014-01-01

    The use of handheld devices such as smart phones and tablets have exploded in the last few years. These mobile devices differ from regular desktops by having limited battery power, processing power, bandwidth, internal memory, and screen size. With many device types and with mobile adaptation being done in many ways, it is therefore important for websites to adapt to mobile users. This thesis characterise how websites currently are adapting to mobile devices. For our analysis and data collect...

  6. A Grid Service Infrastructure for Mobile Devices

    OpenAIRE

    Guan, Tao; Zaluska, Ed; de Roure, David

    2005-01-01

    One of the visions of Grid computing is to access computational resources automatically on demand to deliver the services required with appropriate quality. Because mobile devices are now increasingly common, an infrastructure is required to allow mobile devices to use Grid services, and thus enable the execution of complex resource-intensive applications on the resource-constrained devices. We present a system infrastructure that allows local mobile devices to interact with the Grid. Central...

  7. Nanostructured energy devices equilibrium concepts and kinetics

    CERN Document Server

    Bisquert, Juan

    2014-01-01

    Due to the pressing needs of society, low cost materials for energy devices have experienced an outstanding development in recent times. In this highly multidisciplinary area, chemistry, material science, physics, and electrochemistry meet to develop new materials and devices that perform required energy conversion and storage processes with high efficiency, adequate capabilities for required applications, and low production cost. Nanostructured Energy Devices: Equilibrium Concepts and Kinetics introduces the main physicochemical principles that govern the operation of energy devices. It inclu

  8. Three terminal non-equilibrium superconducting devices

    International Nuclear Information System (INIS)

    I review various non-equilibrium three terminal superconducting devices. The Quiteron, while initially promising, has major failings that make it uncompetitive as a high speed three terminal device. By examining alternatives to the Quiteron structure we come to the conclusion that a quasiparticle injected microstrip device somewhat similar in concept to the original CLINK device of Wong et al. has considerable promise, provided that a low carrier density superconductor is employed as the microstrip material. (orig./BUD)

  9. Software for Wearable Devices: Challenges and Opportunities

    OpenAIRE

    Jiang, He; Chen, Xin; Zhang, Shuwei; Zhang, Xin; Kong, Weiqiang; Zhang, Tao

    2015-01-01

    Wearable devices are a new form of mobile computer system that provides exclusive and user-personalized services. Wearable devices bring new issues and challenges to computer science and technology. This paper summarizes the development process and the categories of wearable devices. In addition, we present new key issues arising in aspects of wearable devices, including operating systems, database management system, network communication protocol, application development platform, privacy an...

  10. Synaptic electronics: materials, devices and applications

    International Nuclear Information System (INIS)

    In this paper, the recent progress of synaptic electronics is reviewed. The basics of biological synaptic plasticity and learning are described. The material properties and electrical switching characteristics of a variety of synaptic devices are discussed, with a focus on the use of synaptic devices for neuromorphic or brain-inspired computing. Performance metrics desirable for large-scale implementations of synaptic devices are illustrated. A review of recent work on targeted computing applications with synaptic devices is presented. (topical review)

  11. Metrological Reliability of Medical Devices

    Science.gov (United States)

    Costa Monteiro, E.; Leon, L. F.

    2015-02-01

    The prominent development of health technologies of the 20th century triggered demands for metrological reliability of physiological measurements comprising physical, chemical and biological quantities, essential to ensure accurate and comparable results of clinical measurements. In the present work, aspects concerning metrological reliability in premarket and postmarket assessments of medical devices are discussed, pointing out challenges to be overcome. In addition, considering the social relevance of the biomeasurements results, Biometrological Principles to be pursued by research and innovation aimed at biomedical applications are proposed, along with the analysis of their contributions to guarantee the innovative health technologies compliance with the main ethical pillars of Bioethics.

  12. Fundamentals of liquid crystal devices

    CERN Document Server

    Yang, Deng-Ke

    2014-01-01

    Revised throughout to cover the latest developments in the fast moving area of display technology, this 2nd edition of Fundamentals of Liquid Crystal Devices, will continue to be a valuable resource for those wishing to understand the operation of liquid crystal displays. Significant updates include new material on display components, 3D LCDs and blue-phase displays which is one of the most promising new technologies within the field of displays and it is expected that this new LC-technology will reduce the response time and the number of optical components of LC-modules. Prof. Yang is a pion

  13. Cavity Solitons in VCSEL Devices

    Directory of Open Access Journals (Sweden)

    S. Barbay

    2011-01-01

    Full Text Available We review advances on the experimental study of cavity solitons in VCSELs in the past decade. We emphasize on the design and fabrication of electrically or optically pumped broad-area VCSELs used for CSs formation and review different experimental configurations. Potential applications of CSs in the field of photonics are discussed, in particular the use of CSs for all-optical processing of information and for VCSELs characterization. Prospects on self-localization studies based on vertical cavity devices involving new physical mechanisms are also given.

  14. Capacitor ageing in electronic devices

    Directory of Open Access Journals (Sweden)

    Richard B. N. Vital

    2015-10-01

    Full Text Available The moment when an electronic component doesn’t work like requirements, previously established is a task that need to be considered since began of a system design. However, the use of different technologies, operating under several environmental conditions, makes a component choice a complex step in system design. This paper analyzes the effects that ageing phenomenon of capacitors may introduce in electronic devices operation. For this reason, reliability concepts, processes and mechanism of degradation are presented. Additionally, some mathematical models are presented to assist maintenance activities or component replacement. The presented approach compares the operability of intact and aged components.

  15. Low energy ion storage devices

    International Nuclear Information System (INIS)

    While high energy physicists have found it expedient to store ions at increasingly higher energies in devices of greater size and complexity, atomic physicists have generally attempted to store ions at ever lower energies, and often in miniaturized containers. However, many of the techniques used at both high and low energies are analogous or related. Three basic means of ion containment have been used: the dc electrostatic trap, the Penning-type trap with uniform magnetic field and quadrupole dc potential, and the radio-frequency quadrupole trap in either the cylindrically symmetric or storage-ring configurations. Each trapping configuration has characteristic advantages or drawbacks for particular measurements. Each method is described

  16. Wavelength conversion devices and techniques

    DEFF Research Database (Denmark)

    Stubkjær, Kristian; Jørgensen, Carsten; Danielsen, Søren Lykke;

    1996-01-01

    Wavelength division multiplexed (WDM) networks are currently subject to an immense interest because of the extra capacity and flexibility they provide together with the possibilities for graceful system upgrades. For full network flexibility it is very attractive to be able to translate the chann...... wavelengths in an easy way and preferably without opto-electronic conversion. Here, we will first briefly look at advantages of employing optical wavelength converters in WDM networks and next review the optical wavelength conversion devices with emphasis on recent developments....

  17. Electrical devices and remote monitoring

    International Nuclear Information System (INIS)

    New technologies are being applied in all spheres of life such as phones and computers. Since 2001 this technologies are incorporated, to implantable devices, such as Holter monitoring, pacemaker defibrillators and resynchronizers. Furthermore, the use of this technology, requires significant adaptation and change in traditional methods, is simple to use, versatile, and has shown a lot of benefits to patient care and medical activity. Increasingly tracking units pacemakers or defibrillators are using these monitoring systems and are being applied to a larger volume of patients

  18. Design of microwave active devices

    CERN Document Server

    Gautier , Jean-Luc

    2014-01-01

    This book presents methods for the design of the main microwave active devices. The first chapter focuses on amplifiers working in the linear mode. The authors present the problems surrounding narrowband and wideband impedance matching, stability, polarization and the noise factor, as well as specific topologies such as the distributed amplifier and the differential amplifier. Chapter 2 concerns the power amplifier operation. Specific aspects on efficiency, impedance matching and class of operation are presented, as well as the main methods of linearization and efficiency improvement. Freq

  19. Geospatial computing in mobile devices

    CERN Document Server

    Chen, Ruizhi

    2014-01-01

    Geospatial computing includes utilizing computing devices and sensors to acquire, process, analyze, manage, and visualize geospatial data, which users can then interact with via a large variety of smart geospatial applications. Geospatial computing is a computational-demanding task, in terms of computation power, data storage capacity, and memory space. Therefore, it has primarily been performed on non-mobile computers. Recent developments allow smartphones to meet many of the demanded requirements for geospatial computing.This book addresses the topic of geospatial computing in smartphones, i

  20. Spintronics from materials to devices

    CERN Document Server

    Felser, Claudia

    2013-01-01

    Spintronics is an emerging technology exploiting the spin degree of freedom and has proved to be very promising for new types of fast electronic devices. Amongst the anticipated advantages of spintronics technologies, researchers have identified the non-volatile storage of data with high density and low energy consumption as particularly relevant. This monograph examines the concept of half-metallic compounds perspectives to obtain novel solutions and discusses several oxides such as perovskites, double perovskites and CrO2 as well as Heusler compounds. Such materials can be designed and made

  1. Osteocyte culture in microfluidic devices

    OpenAIRE

    Wei, Chao; Fan, Beiyuan; Chen, Deyong; Liu, Chao; Wei, Yuanchen; Huo, Bo; You, Lidan; Wang, Junbo; Chen, Jian

    2015-01-01

    This paper presents a microfluidic device (poly-dimethylsiloxane micro channels bonded with glass slides) enabling culture of MLO-Y4 osteocyte like cells. In this study, on-chip collagen coating, cell seeding and culture, as well as staining were demonstrated in a tubing-free manner where gravity was used as the driving force for liquid transportation. MLO-Y4 cells were cultured in microfluidic channels with and without collagen coating where cellular images in a time sequence were taken and ...

  2. Mobile devices tools and technologies

    CERN Document Server

    Collins, Lauren

    2015-01-01

    Mobile Devices: Tools and Technologies provides readers with an understanding of the mobile landscape available to app developers, system and network engineers, and the avid techie. As the trend of mobile technology has enabled the continuous development of ubiquitous applications, this book offers insights into tools and technologies critical to evaluating and implementing mobile strategies.The book is organized into four parts of 18 contributed chapters written by engineers in the areas of application and database development, mobile enterprise strategy, and networking and security. Througho

  3. Photoelectric devices with quantum coherence

    Science.gov (United States)

    Shanhe, Su

    A phtotoelectric device consisting of a three-level system contacted with two fermionic baths and a photon bath is built. Making the Born-Markov approximation, the equation of motion for the density operator in a Lindblad-like form is derived. We obtain the coherence and the efficiency of the system under the steady-state condition. Results show that quantum coherence can enhance the photoelectric conversion efficiency. The efficiency at maximum power can be larger than the CA efficiency bound with the existence of coherence.

  4. Tunable circuit for tunable capacitor devices

    Science.gov (United States)

    Rivkina, Tatiana; Ginley, David S.

    2006-09-19

    A tunable circuit (10) for a capacitively tunable capacitor device (12) is provided. The tunable circuit (10) comprises a tunable circuit element (14) and a non-tunable dielectric element (16) coupled to the tunable circuit element (16). A tunable capacitor device (12) and a method for increasing the figure of merit in a tunable capacitor device (12) are also provided.

  5. Creating Learning Experiences through Interactive Devices

    Science.gov (United States)

    Harvey, Alexis

    2014-01-01

    In this small-scale study, the use of a simple interactive device was designed and studied ethnographically to discover how groups visiting a museum as part of a guided tour interacted with the device as viewed from the perspective of the group tour guides. As the emphasis placed on utilizing interactive devices in museums is increasing, one can…

  6. Electrostatic MEMS devices with high reliability

    Science.gov (United States)

    Goldsmith, Charles L; Auciello, Orlando H; Sumant, Anirudha V; Mancini, Derrick C; Gudeman, Chris; Sampath, Suresh; Carlilse, John A; Carpick, Robert W; Hwang, James

    2015-02-24

    The present invention provides for an electrostatic microelectromechanical (MEMS) device comprising a dielectric layer separating a first conductor and a second conductor. The first conductor is moveable towards the second conductor, when a voltage is applied to the MEMS device. The dielectric layer recovers from dielectric charging failure almost immediately upon removal of the voltage from the MEMS device.

  7. Investigation of Electronic Corrosion at Device Level

    DEFF Research Database (Denmark)

    Jellesen, Morten Stendahl; Minzari, Daniel; Rathinavelu, Umadevi;

    2010-01-01

    This work presents device level testing of a lead free soldered electronic device tested with bias on under cyclic humidity conditions in a climatic chamber. Besides severe temperature and humidity during testing some devices were deliberately contaminated before testing. Contaminants investigated...

  8. 75 FR 16351 - Medical Devices; Technical Amendment

    Science.gov (United States)

    2010-04-01

    ..., and 1050 Medical Devices; Technical Amendment AGENCY: Food and Drug Administration, HHS. ACTION: Final.... 360hh- 360ss). The Safe Medical Devices Act of 1990 (SMDA) (Public Law 101- 629), transferred the... protection. 21 CFR Part 1020 Electronic products, Medical devices, Radiation protection, Reporting...

  9. Organic electrophosphorescence device having interfacial layers

    Science.gov (United States)

    Choulis, Stelios A.; Mathai, Mathew; Choong, Vi-En; So, Franky

    2010-08-10

    Techniques are described for forming an organic light emitting diode device with improved device efficiency. Materials having at least one energy level that is similar to those of a phosphorescent light emitting material in the diode are incorporated into the device to directly inject holes or electrons to the light emitting material.

  10. Emulsification with micro-engineered devices

    OpenAIRE

    Geerken, Maik Jörn

    2006-01-01

    This thesis deals with the formation of emulsions using micro-engineered devices. It covers devices made from silicon nitride, metals and polymers using different types of micro-processing tools for their fabrication. In order to produce water-in-oil emulsions, surface modifications were applied to render the surface of the metal and silicon nitride devices hydrophobic.

  11. [Consideration of Mobile Medical Device Regulation].

    Science.gov (United States)

    Peng, Liang; Yang, Pengfei; He, Weigang

    2015-07-01

    The regulation of mobile medical devices is one of the hot topics in the industry now. The definition, regulation scope and requirements, potential risks of mobile medical devices were analyzed and discussed based on mobile computing techniques and the FDA guidance of mobile medical applications. The regulation work of mobile medical devices in China needs to adopt the risk-based method. PMID:26665948

  12. 21 CFR 820.130 - Device packaging.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Device packaging. 820.130 Section 820.130 Food and... QUALITY SYSTEM REGULATION Labeling and Packaging Control § 820.130 Device packaging. Each manufacturer shall ensure that device packaging and shipping containers are designed and constructed to protect...

  13. Assistive Devices for Students with Disabilities.

    Science.gov (United States)

    Wisniewski, Lech; Sedlak, Robert

    1992-01-01

    Describes a variety of devices that can assist students with disabilities. Highlights recently developed devices for students with specific learning disabilities, and with vision, hearing, health, physical, and speech and language impairments. The devices can help rehabilitate, reeducate, facilitate normalcy, or augment current functioning. (GLR)

  14. After-heat removing device

    International Nuclear Information System (INIS)

    Air cooling devices of a plurality of loops are arranged, each of the cooling device comprises a damper and a vane therein, and a heat transfer tube is inserted between the damper and the vane. The minimum limit value for the opening degree of each of the damper and the vane is changed stepwise for each of the loops. After reactor shutdown, the opening degree of the damper and the vane for each of the loops is simultaneously fixed to the minimum opening degree set for each of the loops. Since the amount of inflown air to the loop having the damper and the vane of the maximum opening degree is greater compared with that of other loops, and the amount of heat removal is maximum, coolants in a heat transfer tube portion are frozen in a short period of time and heat removal is impossible. Then, after heat is successively removed by other loops set to smaller opening degree for the damper and the vane. With such procedures, degradation of reliability due to erroneous closure of the damper and the vane can be eliminated with no requirement for an operator's control for the opening degree. (I.N.)

  15. Osteocyte culture in microfluidic devices.

    Science.gov (United States)

    Wei, Chao; Fan, Beiyuan; Chen, Deyong; Liu, Chao; Wei, Yuanchen; Huo, Bo; You, Lidan; Wang, Junbo; Chen, Jian

    2015-01-01

    This paper presents a microfluidic device (poly-dimethylsiloxane micro channels bonded with glass slides) enabling culture of MLO-Y4 osteocyte like cells. In this study, on-chip collagen coating, cell seeding and culture, as well as staining were demonstrated in a tubing-free manner where gravity was used as the driving force for liquid transportation. MLO-Y4 cells were cultured in microfluidic channels with and without collagen coating where cellular images in a time sequence were taken and analyzed, confirming the positive effect of collagen coating on phenotype maintaining of MLO-Y4 cells. The proliferating cell nuclear antigen based proliferation assay was used to study cellular proliferation, revealing a higher proliferation rate of MLO-Y4 cells seeded in microfluidic channels without collagen coating compared to the substrates coated with collagen. Furthermore, the effects of channel dimensions (variations in width and height) on the viability of MLO-Y4 cells were explored based on the Calcein-AM and propidium iodide based live/dead assay and the Hoechst 33258 based apoptosis assay, locating the correlation between the decrease in channel width or height and the decrease in cell viability. As a platform technology, this microfluidic device may function as a new cell culture model enabling studies of osteocytes. PMID:25713691

  16. Device for absorbing mechanical shock

    International Nuclear Information System (INIS)

    This invention is a comparatively inexpensive but efficient shock-absorbing device having special application to the protection of shipping and storage cylinders. In a typical application, two of the devices are strapped to a cylinder to serve as saddle-type supports for the cylinder during storage and to protect the cylinder in the event it is dropped during lifting or lowering operations. In its preferred form, the invention includes a hardwood plank whose grain runs in the longitudinal direction. The basal portion of the plank is of solid cross-section, whereas the upper face of the plank is cut away to form a concave surface fittable against the sidewall of a storage cylinder. The concave surface is divided into a series of segments by transversely extending, throughgoing relief slots. A layer of elastomeric material is positioned on the concave face, the elastomer being extrudable into slots when pressed against the segments by a preselected pressure characteristic of a high-energy impact. The compressive, tensile, and shear properties of the hardwood and the elastomer are utilized in combination to provide a surprisingly high energy -absorption capability

  17. Gaseous radioactive waste processing device

    International Nuclear Information System (INIS)

    A high temperature water feed line connecting a heating steam line as a heat source for an off-gas pre-heater and a desalting water feed line is connected to the exit and inlet of an off-gas recombiner, and a drain discharge port is disposed at the lower portion of the off-gas recombiner. A ventilation port capable of sending air is disposed to the off-gas inlet of the off-gas pre-heater. The off-gas processing device uses a high temperature water, as a recombiner cleaning medium, prepared by mixing heated steams at about 170degC as a heat source of the off-gas pre-heater and a desalting water at normal temperature. Accordingly, impurities deposited strongly to the surface of the catalysts can be removed by the vigorous movement of moleculers of the high temperature water. This can improve the corrosive environment of the device, facilitate the cleaning of the off-gas recombiner catalyst, and conduct the process frequently. Then, the life time of the catalysts can be extended by maintaining the catalyst performance. (T.M.)

  18. Silicon single-electron devices

    International Nuclear Information System (INIS)

    Single-electron devices (SEDs) are attracting a lot of attention because of their capability of manipulating just one electron. For their operation, they utilize the Coulomb blockade (CB), which occurs in tiny structures made from conductive material due to the electrostatic interactions of confined electrons. Metals or III-V compound semiconductors have so far been used to investigate the CB and related phenomena from the physical point of view. However, silicon is preferable from the viewpoint of applications to integrated circuits because, on a silicon substrate, SEDs can be used in combination with conventional complementary metal-oxide-semiconductor (CMOS) circuits. In addition, the well established fabrication technologies for CMOS large-scale integrated circuits (LSIs) can be applied to making such small structures. LSI applications of the silicon SEDs can be categorized into two fields: memory and logic. Many kinds of device structure and fabrication process have been proposed and tested for these purposes. This paper introduces the current status of silicon-based SED studies for LSI applications. (author)

  19. Thermonuclear device, and plasma control method and device therefor

    International Nuclear Information System (INIS)

    In the present invention, an amount of unnecessary escaping electrons at high energy generated upon occurrence of plasma disruption is decreased by controlling magnetic fields, to prevent injuries of plasma-facing walls of a thermonuclear device due to the escaping electrons. That is, a means is disposed for changing the position of plasmas or the position of a magnetic axis to the outside of a vacuum vessel when occurrence of plasma disruption is detected. Thus, plasma electric current is decayed by rapidly transferring a magnetic field coordination upon occurrence of disruption. That is, when the movement of the magnetic axis is detected and, if it is increased to such a level that the decay of the plasma current is inevitable or when the decay of electric current due to occurrence of disruption is observed, the magnetic fields are controlled by rapidly transferring the magnetic coordination and keeping such a state. (I.S.)

  20. Graded junction termination extensions for electronic devices

    Science.gov (United States)

    Merrett, J. Neil (Inventor); Isaacs-Smith, Tamara (Inventor); Sheridan, David C. (Inventor); Williams, John R. (Inventor)

    2007-01-01

    A graded junction termination extension in a silicon carbide (SiC) semiconductor device and method of its fabrication using ion implementation techniques is provided for high power devices. The properties of silicon carbide (SiC) make this wide band gap semiconductor a promising material for high power devices. This potential is demonstrated in various devices such as p-n diodes, Schottky diodes, bipolar junction transistors, thyristors, etc. These devices require adequate and affordable termination techniques to reduce leakage current and increase breakdown voltage in order to maximize power handling capabilities. The graded junction termination extension disclosed is effective, self-aligned, and simplifies the implementation process.