WorldWideScience

Sample records for circulating venous bubbles

  1. Influence of Bubble-Bubble interactions on the macroscale circulation patterns in a bubbling gas-solid fluidized bed

    NARCIS (Netherlands)

    Laverman, J.A.; van Sint Annaland, M.; Kuipers, J.A.M.

    2007-01-01

    The macro-scale circulation patterns in the emulsion phase of a gas-solid fluidized bed in the bubbling regime have been studied with a 3D Discrete Bubble Model. It has been shown that bubble-bubble interactions strongly influence the extent of the solids circulation and the bubble size

  2. Hypodense bubbles in acute extradural haematomas following venous sinus tear

    International Nuclear Information System (INIS)

    Chee, C.P.; Habib, Z.A.

    1991-01-01

    Between January 1982 and December 1989, 12 patients with 13 acute extradural haematomas as a result of injury involving the venous sinuses were treated by the first author. The CT scan apperances in 6 cases were remarkable in that there were large bubbles of low density in the hyperdense haematomas and liquid blood was found during the operation. The possible underlying pathophysiological changes that gave rise this appearance are discussed. The CT scan appearance and the proximity of the clot to the venous sinuses should alert the neurosurgeon to the high probabilities of venous sinus tear such that proper treatment can be offered. (orig.)

  3. Hypodense bubbles in acute extradural haematomas following venous sinus tear

    Energy Technology Data Exchange (ETDEWEB)

    Chee, C.P.; Habib, Z.A. (Malaya Univ. Hospital, Kuala Lumpur (Malaysia). Neurosurgical and Radiological Services)

    1991-04-01

    Between January 1982 and December 1989, 12 patients with 13 acute extradural haematomas as a result of injury involving the venous sinuses were treated by the first author. The CT scan apperances in 6 cases were remarkable in that there were large bubbles of low density in the hyperdense haematomas and liquid blood was found during the operation. The possible underlying pathophysiological changes that gave rise this appearance are discussed. The CT scan appearance and the proximity of the clot to the venous sinuses should alert the neurosurgeon to the high probabilities of venous sinus tear such that proper treatment can be offered. (orig.).

  4. Toroidal bubbles with circulation in ideal hydrodynamics: A variational approach

    DEFF Research Database (Denmark)

    Ruban, V.P.; Juul Rasmussen, J.

    2003-01-01

    Incompressible, inviscid, irrotational, unsteady flows with circulation Gamma around a distorted toroidal bubble are considered. A general variational principle that determines the evolution of the bubble shape is formulated. For a two-dimensional (2D) cavity with a constant area A, exact...... pseudodifferential equations of motion are derived, based on variables that determine a conformal mapping of the unit circle exterior into the region occupied by the fluid. A closed expression for the Hamiltonian of the 2D system in terms of canonical variables is obtained. Stability of a stationary drifting 2D...... hollow vortex is demonstrated, when the gravity is small, gA(3/2)/Gamma(2)circulation-dominated regime of three-dimensional flows a simplified Lagrangian is suggested, inasmuch as the bubble shape is well described by the center line R(xi,t) and by an approximately circular cross section...

  5. Enriched Air Nitrox Breathing Reduces Venous Gas Bubbles after Simulated SCUBA Diving: A Double-Blind Cross-Over Randomized Trial.

    Directory of Open Access Journals (Sweden)

    Vincent Souday

    Full Text Available To test the hypothesis whether enriched air nitrox (EAN breathing during simulated diving reduces decompression stress when compared to compressed air breathing as assessed by intravascular bubble formation after decompression.Human volunteers underwent a first simulated dive breathing compressed air to include subjects prone to post-decompression venous gas bubbling. Twelve subjects prone to bubbling underwent a double-blind, randomized, cross-over trial including one simulated dive breathing compressed air, and one dive breathing EAN (36% O2 in a hyperbaric chamber, with identical diving profiles (28 msw for 55 minutes. Intravascular bubble formation was assessed after decompression using pulmonary artery pulsed Doppler.Twelve subjects showing high bubble production were included for the cross-over trial, and all completed the experimental protocol. In the randomized protocol, EAN significantly reduced the bubble score at all time points (cumulative bubble scores: 1 [0-3.5] vs. 8 [4.5-10]; P < 0.001. Three decompression incidents, all presenting as cutaneous itching, occurred in the air versus zero in the EAN group (P = 0.217. Weak correlations were observed between bubble scores and age or body mass index, respectively.EAN breathing markedly reduces venous gas bubble emboli after decompression in volunteers selected for susceptibility for intravascular bubble formation. When using similar diving profiles and avoiding oxygen toxicity limits, EAN increases safety of diving as compared to compressed air breathing.ISRCTN 31681480.

  6. Hydrodynamics of circulating and bubbling fluidized beds

    International Nuclear Information System (INIS)

    Gidaspow, D.P.; Tsuo, Y.P.; Ding, J.

    1991-01-01

    This paper reports that a review of modeling of the hydrodynamics of fluidization of bubbling beds showed that inviscid two-fluid models were able to predict a great deal of the behavior of bubbling beds because the dominant mechanism of energy dissipation is the drag between the particles and the fluid. The formation, the growth and the bursting of bubbles were predicted. Predicted wall-to-bed heat transfer coefficients and velocity profiles of jets agreed with measurements. Time average porosity distributions agreed with measurements done using gamma-ray densitometers without the use of any adjustable parameters. However, inviscid models could not correctly predict rates of erosion around tubes immersed into fluidized beds. To correctly model such behavior, granular stresses involving solids viscosity were added into the computer model. This viscosity arises due to random collision of particles. Several models fro this viscosity were investigated and the results compared to measurements of solids distributions in two-dimensional beds and to particle velocities reported in the literature. While in the case of bubbling beds the solids viscosity plays the role of a correction, modeling of a circulating fluidized bed (CFB) without a viscosity is not possible. Recent experimental data obtained at IIT and at IGT show that in CFB the solids viscous dissipation is responsible for as much as half of the pressure drop. From such measurement, solids viscosities were computed. These were used in the two fluid hydrodynamic model, to predict radial solids distributions and solids velocities which matched the experimental distributions. Most important, the model predicted cluster formation and transient internal circulation which is responsible for the favorable characteristics of CFBs, such as good wall-to-bed heat transfer. Video tape movies of computations compared favorably with high speed movies of the experiments

  7. Bubble removal from glass melts with slow vertical circulation

    Czech Academy of Sciences Publication Activity Database

    Jebavá, M.; Němec, Lubomír

    2011-01-01

    Roč. 55, č. 3 (2011), s. 232-239 ISSN 0862-5468 Institutional research plan: CEZ:AV0Z40320502 Keywords : bubbles * glass-melt circulation * pot furnace * mathematical modelling * fining efficiency Subject RIV: JH - Ceramics, Fire-Resistant Materials and Glass Impact factor: 0.382, year: 2011

  8. Inner-ear circulation in humans is disrupted by extracranial venous outflow strictures: Implications for Ménière’s disease

    Directory of Open Access Journals (Sweden)

    Eleuterio F. Toro

    2018-02-01

    Full Text Available Ménière’s disease (MD is a pathology of the inner ear, the symptoms of which include tinnitus, vertigo attacks, fluctuating hearing loss, and nausea. Neither cause nor cure are currently known, though animal experiments suggest that disruption of the inner ear circulation, including venous hypertension and endolymphatic hydrops, to be hallmarks of the disease. Recent evidence for humans suggests a potential link to strictures in the extracranial venous outflow routes. The purpose of the present work is to demonstrate that the inner-ear circulation in humans is disrupted by extracranial venous outflow stricture and to discuss the implications of this finding for MD. The hypothesis linking extracranial venous outflow strictures to the altered dynamics of central nervous system (CNS fluid compartments is investigated theoretically via a global, closed-loop, multiscale mathematical model for the entire human circulation, interacting with the brain parenchyma and cerebrospinal fluid (CSF. The fluid dynamics model for the full human body includes submodels for the heart, pulmonary circulation, arterial system, microvasculature, venous system and the CSF, with a specially refined description of the inner ear vasculature. We demonstrate that extracranial venous outflow strictures disrupt inner ear circulation, and more generally, alter the dynamics of fluid compartments in the whole CNS. Specifically, as compared to a healthy control, the computational results from our model show that subjects with extracranial outflow venous strictures exhibit: altered inner ear circulation, redirection of flow to collaterals, increased intracranial venous pressure and increased intracranial pressure. Our findings are consistent with recent clinical evidence in humans that links extracranial outflow venous strictures to MD, aid the mechanistic understanding of the underlying features of the disease and lend support to recently proposed biophysically motivated

  9. Intraoperative visible bubbling of air may be the first sign of venous air embolism during posterior surgery for scoliosis.

    Science.gov (United States)

    Wills, John; Schwend, Richard M; Paterson, Andrew; Albin, Maurice S

    2005-10-15

    Case report of two children sustaining venous air embolism (VAE) during posterior surgery for scoliosis. To report 2 cases where visible bubbling at the operative site was the first clinical indication of VAE-induced cardiovascular collapse and to raise the level of consciousness that VAE in the prone position can occur, often with serious consequences. Twenty-two cases of VAE during surgery for scoliosis in the prone position have been reported. Ten were fatal and ten were in children. Visible bubbling at the operative site was noted in two published cases. Retrospective study of 2 cases of VAE at one institution. Clinical, anesthetic, and radiographic features are presented. Details of previously published cases are reviewed and discussed. Both patients were girls with adolescent scoliosis who underwent prone positioned posterior spinal fusion with instrumentation. Visible bubbling of air at the thoracic aspect of the surgical site was noted near the completion of instrumentation and was the first indication of VAE. In both cases, this was clinically recognized and promptly treated. One patient survived normally and the other died. Visible air bubbling at the operative site may herald the onset of massive VAE during multilevel posterior spinal fusion and instrumentation. A prospective multicenter study using precordial Doppler, central venous catheter, and end-tidal CO2 is recommended to determine the true incidence of VAE in spinal deformity surgery and to evaluate monitoring and treatment methods.

  10. Counteracting negative venous line pressures to avoid arterial air bubbles: an experimental study comparing two different types of miniaturized extracorporeal perfusion systems.

    Science.gov (United States)

    Aboud, Anas; Mederos-Dahms, Hendrikje; Liebing, Kai; Zittermann, Armin; Schubert, Harald; Murray, Edward; Renner, Andre; Gummert, Jan; Börgermann, Jochen

    2015-05-29

    Because of its low rate of clinical complications, miniaturized extracorporeal perfusion systems (MEPS) are frequently used in heart centers worldwide. However, many recent studies refer to the higher probability of gaseous microemboli formation by MEPS, caused by subzero pressure values. This is the main reason why various de-airing devices were developed for today's perfusion systems. In the present study, we investigated the potential benefits of a simple one-way-valve connected to a volume replacement reservoir (OVR) for volume and pressure compensation. In an experimental study on 26 pigs, we compared MEPS (n = 13) with MEPS plus OVR (n = 13). Except OVR, perfusion equipment was identical in both groups. Primary endpoints were pressure values in the venous line and the right atrium as well as the number and volume of air bubbles. Secondary endpoints were biochemical parameters of systemic inflammatory response, ischemia, hemodilution and hemolysis. One animal was lost in the MEPS + OVR group. In the MEPS + OVR group no pressure values below -150 mmHg in the venous line and no values under -100 mmHg in right atrium were noticed. On the contrary, nearly 20% of venous pressure values in the MEPS group were below -150 and approximately 10% of right atrial pressure values were below -100 mmHg. Compared with the MEPS group, the bubble counter device showed lower numbers of arterial air bubbles in the MEPS + OVR group (mean ± SD: 13444 ± 5709 vs. 1 ± 2, respectively; p pressures and to reduce the number and volume of arterial air bubbles. This approach may lead to a lower rate of neurological complications.

  11. Experimental investigation of the effects of inserting a bovine venous valve in the inferior vena cava of Fontan circulation

    Science.gov (United States)

    Santhanakrishnan, Arvind; Johnson, Jacob; Kotz, Monica; Tang, Elaine; Khiabani, Reza; Yoganathan, Ajit; Maher, Kevin

    2012-11-01

    The Fontan procedure is a palliative surgery performed on patients with single ventricle (SV) congenital heart defects. The SV is used for systemic circulation and the venous return from the inferior vena cava (IVC) and superior vena cava (SVC) is routed to the pulmonary arteries (PA), resulting in a total cavopulmonary connection (TCPC). Hepatic venous hypertension is commonly manifested in the Fontan circulation, leading to long-term complications including liver congestion and cirrhosis. Respiratory intrathoracic pressure changes affect the venous return from the IVC to the PA. Using a physical model of an idealized TCPC, we examine placement of a unidirectional bovine venous valve within the IVC as a method of alleviating hepatic venous hypertension. A piston pump is used to provide pulsatility in the internal flow through the TCPC, while intrathoracic pressure fluctuations are imposed on the external walls of the model using a pair of linear actuators. When implanted in the extrathoracic position, the hepatic venous pressure is lowered from baseline condition. The effects of changing caval flow distribution and intrathoracic pressure on TCPC hemodynamics will be examined.

  12. Cardiovascular Pressures with Venous Gas Embolism and Decompression

    Science.gov (United States)

    Butler, B. D.; Robinson, R.; Sutton, T.; Kemper, G. B.

    1995-01-01

    Venous gas embolism (VGE) is reported with decompression to a decreased ambient pressure. With severe decompression, or in cases where an intracardiac septal defect (patent foramen ovale) exists, the venous bubbles can become arterialized and cause neurological decompression illness. Incidence rates of patent foramen ovale in the general population range from 25-34% and yet aviators, astronauts, and deepsea divers who have decompression-induced venous bubbles do not demonstrate neurological symptoms at these high rates. This apparent disparity may be attributable to the normal pressure gradient across the atria of the heart that must be reversed for there to be flow potency. We evaluated the effects of: venous gas embolism (0.025, 0.05 and 0.15 ml/ kg min for 180 min.) hyperbaric decompression; and hypobaric decompression on the pressure gradient across the left and right atria in anesthetized dogs with intact atrial septa. Left ventricular end-diastolic pressure was used as a measure of left atrial pressure. In a total of 92 experimental evaluations in 22 dogs, there were no reported reversals in the mean pressure gradient across the atria; a total of 3 transient reversals occurred during the peak pressure gradient changes. The reasons that decompression-induced venous bubbles do not consistently cause serious symptoms of decompression illness may be that the amount of venous gas does not always cause sufficient pressure reversal across a patent foramen ovale to cause arterialization of the venous bubbles.

  13. Performance Tests for Bubble Blockage Device

    International Nuclear Information System (INIS)

    Ha, Kwang Soon; Wi, Kyung Jin; Park, Rae Joon; Wan, Han Seong

    2014-01-01

    Postulated severe core damage accidents have a high threat risk for the safety of human health and jeopardize the environment. Versatile measures have been suggested and applied to mitigate severe accidents in nuclear power plants. To improve the thermal margin for the severe accident measures in high-power reactors, engineered corium cooling systems involving boiling-induced two-phase natural circulation have been proposed for decay heat removal. A boiling-induced natural circulation flow is generated in a coolant path between a hot vessel wall and cold coolant reservoir. In general, it is possible for some bubbles to be entrained in the natural circulation loop. If some bubbles entrain in the liquid phase flow passage, flow instability may occur, that is, the natural circulation mass flow rate may be oscillated. A new device to block the entraining bubbles is proposed and verified using air-water test loop. To avoid bubbles entrained in the natural circulation flow loop, a new device was proposed and verified using an air-water test loop. The air injection and liquid circulation loop was prepared, and the tests for the bubble blockage devices were performed by varying the geometry and shape of the devices. The performance of the bubble blockage device was more effective as the area ratio of the inlet to the down-comer increased, and the device height decreased. If the device has a rim to generate a vortex zone, the bubbles will be most effectively blocked

  14. Influence of cross-sectional ratio of down comer to riser on the efficiency of liquid circulation in loop air lift bubble column

    Science.gov (United States)

    Yamamoto, Tatsumi; Kawasaki, Hiroyuki; Mori, Hidetoshi

    2017-11-01

    Loop type bubble columns have good performance of liquid circulation and mass transfer by airlift effect, where the liquid circulation time is an important measurable characteristic parameter. This parameter is affected by the column construction, the aspect ratio of the column, the cross-sectional area ratio of down comer to riser (R), and the superficial gas velocity in the riser (UGR). In this work, the mean gas holdup and the liquid circulation time (TC) have been measured in four types of loop airlift type bubble column: concentric tube internal loop airlift type, rectangular internal loop airlift type, external loop airlift type, external loop airlift with separator. Air and tap water were used as gas and liquid phase, respectively. The results have demonstrated that the mean gas holdup in riser increases in proportion to UGR, and that it in downcomer changes according to the geometric parameters of each bubble column. TC has been found to conform to an empirical equation which depends on UGR and the length of draft tube or division plate in the region of 0.33 < R < 1.

  15. Effects of parasagittal meningiomas on intracranial venous circulation assessed by the virtual reality technology.

    Science.gov (United States)

    Wang, Shousen; Ying, Jianbin; Wei, Liangfeng; Li, Shiqing; Jing, Junjie

    2015-01-01

    This study is to investigate the compensatory intracranial venous pathways in parasagittal meningiomas (PSM) patients by virtual reality technology. A total of 48 PSM patients (tumor group) and 20 patients with trigeminal neuralgia and hemifacial spasm but without intracranial venous diseases (control group) were enrolled. All patients underwent 3D CE-MRV examination. The 3D reconstructed images by virtual reality technology were used for assessment of diameter and number of intracranial veins, tumor location, venous sinus invasion degree and collateral circulation formation. Diameter of bridging veins in posterior 1/3 superior sagittal sinus (SSS) in tumor group was significantly smaller than that of the control group (P < 0.05). For tumors located in mid 1/3 SSS, diameter of bridging veins and vein of Labbé (VL) in posterior 1/3 SSS decreased significantly (P < 0.05). For tumors located in posterior 1/3 SSS, bridging vein number and transverse sinus (TS) diameter significantly decreased while superficial Sylvian vein (SSV) diameter increased significantly (P < 0.05). Compared with tumor in posterior 1/3 SSS subgroup, number of bridging veins in the tumor in mid 1/3 SSS subgroup increased significantly (P < 0.05). Compared with control group, only the bridging vein number in anterior 1/3 SSS segment in invasion Type 3-4 tumor subgroup decreased significantly (P < 0.05). Diameter of TS and bridging veins in posterior 1/3 SSS segment in sinus invasion Type 5-6 tumor subgroup decreased significantly (P < 0.05). Compared with control group, only the diameter of VL and TS of collateral circulation Grade 1 tumor subgroup decreased significantly (P < 0.05) while in Grade 3 tumor subgroup, TS diameter decreased and SSV diameter increased significantly (P < 0.05). The intracranial blood flow is mainly drained through SSV drainage after SSS occlusion by PSM.

  16. Cerebral venous angiomas

    International Nuclear Information System (INIS)

    Agnoli, A.L.; Hildebrandt, G.

    1985-01-01

    Clinical symptoms and radiological signs in 15 patients with cerebral venous malformations are presented and the diagnostic problems discussed. The circulation time in combination with cerebral malformations and angiomas of the scalp are described. CT findings in cases of venous malformations of the brain stem are evaluated. Spot-like enhancement, as well as sharply demarcated round shaped enhancement are characteristic for venous angiomas. Cavernous angiomas usually present as homogenous or inhomogenous round shaped enhanced areas. (Author)

  17. Diagnosis and endovascular treatment of multiple cerebral venous and venous sinuses thrombosis

    International Nuclear Information System (INIS)

    Li Baomin; Zhang Ji; Yin Ling; Huang Xusheng; Jiang Jinli; Liu Jun; Lang Senyang; Zhou Dingbiao; Zhu Ke

    2000-01-01

    Objective: Eighty-five cases with multiple cerebral venous and venous sinuses thrombosis including the diagnosis and endovascular therapy were reported. Methods: The long T2 and short T1 signals in the related regions of multiple venous sinuses on MRI and prolonged blood circulation time of the brain with tortuous dilatation of vein in angiography were the important characteristics for the diagnosis. Of the 85 cases, the treatment procedures were consisted of injecting urokinase intermittently via common carotid artery and intra-sinus contact thrombolysis as well as warfarin intake orally. Results: Intracranial pressure of 80 cases reduced down between 230 and 300 mm H 2 O, and clinical deficits were markedly improved within 10 days. Re-angiography of 18 cases revealed recanalization partly in 5 cases and circulation time appeared near normal i 8 cases during one week after therapy. Conclusions: Combined intraarterial thrombolysis consecutively with general anticoagulation for the treatment of multiple thrombosis in cerebral venous sinuses may be one of the effective means

  18. Resuscitation by hyperbaric exposure from a venous gas emboli following laparoscopic surgery

    DEFF Research Database (Denmark)

    Kjeld, Thomas; Hansen, Egon G; Holler, Nana G

    2012-01-01

    Venous gas embolism is common after laparoscopic surgery but is only rarely of clinical relevance. We present a 52 year old woman undergoing laparoscopic treatment for liver cysts, who also underwent cholecystectomy. She was successfully extubated. However, after a few minutes she developed cardiac......, could have contributed to the formation of the intravascular gas emboli. We conclude that persistent resuscitation followed by hyperbaric oxygen treatment after venous gas emboli contributed to the elimination of intravascular bubbles and the favourable outcome for the patient....... arrest due to a venous carbon dioxide (CO2) embolism as identified by transthoracic echocardiography and aspiration of approximately 7 ml of gas from a central venous catheter. She was resuscitated and subsequently treated with hyperbaric oxygen to reduce the size of remaining gas bubbles. Subsequently...

  19. Integrated drying and incineration of wet sewage sludge in combined bubbling and circulating fluidized bed units.

    Science.gov (United States)

    Li, Shiyuan; Li, Yunyu; Lu, Qinggang; Zhu, Jianguo; Yao, Yao; Bao, Shaolin

    2014-12-01

    An original integrated drying and incineration technique is proposed to dispose of sewage sludge with moisture content of about 80% in a circulating fluidized bed. This system combines a bubbling fluidized bed dryer with a circulating fluidized bed incinerator. After drying, sewage sludge with moisture less than 20% is transported directly and continuously from the fluidized bed dryer into a circulating fluidized bed incinerator. Pilot plant results showed that integrated drying and incineration is feasible in a unique single system. A 100 t/d Sewage Sludge Incineration Demonstration Project was constructed at the Qige sewage treatment plant in Hangzhou City in China. The operational performance showed that the main operation results conformed to the design values, from which it can be concluded that the scale-up of this technique is deemed both feasible and successful. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Sinking bubbles in stout beers

    Science.gov (United States)

    Lee, W. T.; Kaar, S.; O'Brien, S. B. G.

    2018-04-01

    A surprising phenomenon witnessed by many is the sinking bubbles seen in a settling pint of stout beer. Bubbles are less dense than the surrounding fluid so how does this happen? Previous work has shown that the explanation lies in a circulation of fluid promoted by the tilted sides of the glass. However, this work has relied heavily on computational fluid dynamics (CFD) simulations. Here, we show that the phenomenon of sinking bubbles can be predicted using a simple analytic model. To make the model analytically tractable, we work in the limit of small bubbles and consider a simplified geometry. The model confirms both the existence of sinking bubbles and the previously proposed mechanism.

  1. Pneumoperitoneum risk prognosis and correction of venous circulation disturbances in laparoscopic surgery. A pilot study.

    Science.gov (United States)

    Emeljanov, S I; Fedenko, V V; Levite, E M; Panfilov, S A; Bobrinskaya, I G; Fedorov, A V; Matveev, N L; Evdoshenko, V V; Luosev, S V; Bokarev, V V; Musaeva, S R

    1998-10-01

    This study was initiated to find a method of determining the prognosis for possible changes in hemodynamic and respiratory parameters in patients with pneumoperitoneum (PP). We devised a model for a pseudopneumoperitoneum (PPP), which is created by encircling the wide pneumochamber on the entire abdomen and inflating it to a preset pressure. To verify the prognostic possibilities of the proposed model, we studied the pneumotachygraphy parameters, noninvasive and invasive monitoring parameters of PPP after induction of anaesthesia, and venous circulation disturbances, as well as the medical effect of the intermittent sequential compression device. In healthy patients, the restrictive lung syndrome did not approach the risky limit. In patients >/=60 years old, this syndrome was very close to the limit. In a number of patients with serious cardiovascular and pulmonary pathology, the pressure of >10 mmHg was considered to be intolerable. Lung compliance, which was the parameter most sensitive to the increased intraabdominal pressure, was 47 +/- 10 at baseline, and 29 +/- 4 (p > 0.05) at both PPP and real PP (14 mmHg). The PPP model is quite similar to the real PP and can be used for preoperative prognosis in laparoscopic surgery. The elevated intraabdominal pressure results in a significant disturbance of venous blood flow in the lower extremities. The use of the device for peristaltic pneumomassage of the lower limbs is effective in correcting negative changes in venous hemodynamics in laparoscopic surgery.

  2. A system for the discharge of gas bubbles from the coolant flow of a nuclear reactor cooled by forced circulation

    International Nuclear Information System (INIS)

    Markfort, D.; Kaiser, A.; Dohmen, A.

    1975-01-01

    In a reactor cooled by forced circulation the gas bubbles carried along with the coolant flow are separated before entering the reactor core or forced away into the external zones. For this purpose the coolant is radially guided into a plenum below the core and deflected to a tangential direction by means of flow guide elements. The flow runs spirally downwards. On the bubbles, during their dwell time in this channel, the buoyant force and a force towards the axis of symmetry of the tank are exerted. The major part of the coolant is directed into a radial direction by means of a guiding apparatus in the lower section of the channel and guided through a chimney in the plenum to the center of the reactor core. This inner chimney is enclosed by an outer chimney for the core edge zones through which coolant with a small share of bubbles is taken away. (RW) [de

  3. Beneficial effect of enriched air nitrox on bubble formation during scuba diving. An open-water study.

    Science.gov (United States)

    Brebeck, Anne-Kathrin; Deussen, Andreas; Range, Ursula; Balestra, Costantino; Cleveland, Sinclair; Schipke, Jochen D

    2018-03-01

    Bubble formation during scuba diving might induce decompression sickness. This prospective randomised and double-blind study included 108 advanced recreational divers (38 females). Fifty-four pairs of divers, 1 breathing air and the other breathing nitrox28 undertook a standardised dive (24 ± 1 msw; 62 ± 5min) in the Red Sea. Venous gas bubbles were counted (Doppler) 30-air) vs. 11% (air28®) (n.s.) were bubble-free after a dive. Independent of sampling time and breathing gas, there were more bubbles in the jugular than in the femoral vein. More bubbles were counted in the air-group than in the air28-group (pooled vein: early: 1845 vs. 948; P = 0.047, late: 1817 vs. 953; P = 0.088). The number of bubbles was sex-dependent. Lastly, 29% of female air divers but only 14% of male divers were bubble-free (P = 0.058). Air28® helps to reduce venous gas emboli in recreational divers. The bubble number depended on the breathing gas, sampling site and sex. Thus, both exact reporting the dive and in particular standardising sampling characteristics seem mandatory to compare results from different studies to further investigate the hitherto incoherent relation between inert gas bubbles and DCS.

  4. Venous Return and Clinical Hemodynamics: How the Body Works during Acute Hemorrhage

    Science.gov (United States)

    Shen, Tao; Baker, Keith

    2015-01-01

    Venous return is a major determinant of cardiac output. Adjustments within the venous system are critical for maintaining venous pressure during loss in circulating volume. This article reviews two factors that are thought to enable the venous system to compensate during acute hemorrhage: 1) changes in venous elastance and 2) mobilization of…

  5. The analysis of cerebro-vascular circulation time using digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Han, D. G.; Kim, D. H.; Lee, H. K.; Kwon, K. H.; Kim, K. J.

    1986-01-01

    We analyzed the cerebral arterio-venous circulation time of 141 cases of cranial DSA in 136 patients, for the assessment of cerebral circulatory dynamics. IV-DSA was 111 cases, IA-DSA 30 cases. The results were as follows: 1. There was no significant difference in arterio-venous circulation time between IA-DSA and IV-DSA, if the disease pattern was not considered (P > 0.1). 2. Prolongation of arterio-venous circulation time was noted in the cases of cerebral (cerebellar) hemorrhage, subarachnoid hemorrhage, intracranial hematoma, brain abscess, acute stage of cerebra-vascular occlusive disease, acute stage of postoperative follow up, and acute stage of cerebral contusion (p > 0.05). 3. Compared the chronic stage of cerebra-vascular occlusive disease, postoperative follow up, and cerebral contusion with acute stage, significant decrement of arterio-venous circulation time was resulted (p > 0.05). 4. DSA was a useful modality for the assessment of circulatory dynamics, including measurement of arterio-venous circulation time.

  6. Droplets, Bubbles and Ultrasound Interactions.

    Science.gov (United States)

    Shpak, Oleksandr; Verweij, Martin; de Jong, Nico; Versluis, Michel

    2016-01-01

    The interaction of droplets and bubbles with ultrasound has been studied extensively in the last 25 years. Microbubbles are broadly used in diagnostic and therapeutic medical applications, for instance, as ultrasound contrast agents. They have a similar size as red blood cells, and thus are able to circulate within blood vessels. Perfluorocarbon liquid droplets can be a potential new generation of microbubble agents as ultrasound can trigger their conversion into gas bubbles. Prior to activation, they are at least five times smaller in diameter than the resulting bubbles. Together with the violent nature of the phase-transition, the droplets can be used for local drug delivery, embolotherapy, HIFU enhancement and tumor imaging. Here we explain the basics of bubble dynamics, described by the Rayleigh-Plesset equation, bubble resonance frequency, damping and quality factor. We show the elegant calculation of the above characteristics for the case of small amplitude oscillations by linearizing the equations. The effect and importance of a bubble coating and effective surface tension are also discussed. We give the main characteristics of the power spectrum of bubble oscillations. Preceding bubble dynamics, ultrasound propagation is introduced. We explain the speed of sound, nonlinearity and attenuation terms. We examine bubble ultrasound scattering and how it depends on the wave-shape of the incident wave. Finally, we introduce droplet interaction with ultrasound. We elucidate the ultrasound-focusing concept within a droplets sphere, droplet shaking due to media compressibility and droplet phase-conversion dynamics.

  7. Extraction and metabolism of circulating catecholamines by the trout gill

    International Nuclear Information System (INIS)

    Nekvasil, N.P.; Olson, K.R.

    1986-01-01

    Extraction and metabolism of [3H]-norepinephrine (NE) and [3H]epinephrine (E) by the respiratory (efferent branchial) and filamental (venous) vasculature of the trout gill were examined using an isolated perfused arch technique in which outflow from the two circulations was separated. Deaminated and O-methylated metabolites in the effluent were identified by ion-exchange chromatography. Metabolism by tissue homogenates was also measured. Gill homogenates deaminate catecholamines (CAs) faster than homogenates of liver, kidney, and skeletal muscle; branchial O-methylation was comparable to that of liver and kidney. The perfused gill extracted 60% of a NE pulse and 47% of an E pulse. During continuous CA perfusion the gill removed greater than 30% of the NE from the circulation through extraction and metabolism; only 7% of the E was removed. The gill venous system extracts and metabolizes more CAs than the efferent. NE is the preferred substrate for extraction and metabolism. A mechanism is proposed whereby high circulating CA levels, common during stress, are maintained through CA-induced reduction in venous blood flow. After the stress is alleviated, CA levels begin to fall, flow to the venous pathway increases, and the rate of inactivation of circulating CAs increases

  8. Radiology of liver circulation

    International Nuclear Information System (INIS)

    Hermine, C.L.

    1985-01-01

    This book proposes that careful evaluation of the arterioportogram is the cornerstone in assessing portal flow obstruction, being the most consistent of all observations including liver histology, portal venous pressure, size and number of portosystemic collaterals, and wedged hepatic venous pressure. Very brief chapters cover normal hepatic circulation and angiographic methods. Contrast volumes and flow rates for celiac, hepatic, and superior mesenteric injection are given, with the timing for venous phase radiographs. In the main body of the text, portal obstruction is divided very simply into presinusoidal (all proximal causes) and postsinusoidal (all distal causes, including Budd-Chiari). Changes are discussed regarding the splenic artery and spleen; hepatic artery and its branches; portal flow rate and direction; and arterioportal shunting and portosystemic collateral circulation in minimal, moderate, severe, and very severe portal obstruction and in recognizable entities such as prehepatic portal and hepatic venous obstructions. The major emphasis in this section is the recognition and understanding of flow changes by which level and severity of obstruction are assessed (not simply the anatomy of portosystemic collateral venous flow). Excellent final chapters discuss the question of portal hypertension without obstruction, and the contribution of arterioportography to the treatment of portal hypertension, again with an emphasis on hemodynamics before and after shunt surgery. There is a fascinating final chapter on segmental intrahepatic obstruction without portal hypertension that explains much of the unusual contrast enhancement sometimes seen in CT scanning of hepatic mass lesions

  9. Circulating endothelial cells in patients with venous thromboembolism and myeloproliferative neoplasms.

    Directory of Open Access Journals (Sweden)

    Cláudia Torres

    Full Text Available BACKGROUND: Circulating endothelial cells (CEC may be a biomarker of vascular injury and pro-thrombotic tendency, while circulating endothelial progenitor cells (CEP may be an indicator for angiogenesis and vascular remodelling. However, there is not a universally accepted standardized protocol to identify and quantify these cells and its clinical relevancy remains to be established. OBJECTIVES: To quantify CEC and CEP in patients with venous thromboembolism (VTE and with myeloproliferative neoplasms (MPN, to characterize the CEC for the expression of activation (CD54, CD62E and procoagulant (CD142 markers and to investigate whether they correlate with other clinical and laboratory data. PATIENTS AND METHODS: Sixteen patients with VTE, 17 patients with MPN and 20 healthy individuals were studied. The CEC and CEP were quantified and characterized in the blood using flow cytometry, and the demographic, clinical and laboratory data were obtained from hospital records. RESULTS: We found the CEC counts were higher in both patient groups as compared to controls, whereas increased numbers of CEP were found only in patients with MPN. In addition, all disease groups had higher numbers of CD62E+ CEC as compared to controls, whereas only patients with VTE had increased numbers of CD142+ and CD54+ CEC. Moreover, the numbers of total and CD62+ CEC correlated positively with the white blood cells (WBC counts in both groups of patients, while the numbers of CEP correlated positively with the WBC counts only in patients with MPN. In addition, in patients with VTE a positive correlation was found between the numbers of CD54+ CEC and the antithrombin levels, as well as between the CD142+ CEC counts and the number of thrombotic events. CONCLUSIONS: Our study suggests that CEC counts may reveal endothelial injury in patients with VTE and MPN and that CEC may express different activation-related phenotypes depending on the disease status.

  10. Incidental Finding of Inferior Vena Cava Atresia Presenting with Deep Venous Thrombosis following Physical Exertion

    Directory of Open Access Journals (Sweden)

    Shalini Koppisetty

    2015-01-01

    Full Text Available Inferior vena cava atresia (IVCA is a rare but well described vascular anomaly. It is a rare risk factor for deep venous thrombosis (DVT, found in approximately 5% of cases of unprovoked lower extremity (LE DVT in patients <30 years of age. Affected population is in the early thirties, predominantly male, often with a history of major physical exertion and presents with extensive or bilateral DVTs. Patients with IVC anomalies usually develop compensatory circulation through the collateral veins with enlarged azygous/hemizygous veins. Despite the compensatory circulation, the venous drainage of the lower limbs is often insufficient leading to venous stasis and thrombosis. We describe a case of extensive and bilateral deep venous thrombosis following physical exertion in a thirty-six-year-old male patient with incidental finding of IVCA on imaging.

  11. Splanchnic venous thrombosis and pancreatitis.

    Science.gov (United States)

    Nadkarni, Nikhil A; Khanna, Sahil; Vege, Santhi Swaroop

    2013-08-01

    Pancreatitis is an inflammatory process with local and systemic manifestations. One such local manifestation is thrombosis in splanchnic venous circulation, predominantly of the splenic vein. The literature on this important complication is very sparse. This review offers an overview of mechanism of thrombosis, its pathophysiology, diagnosis, and management in the setting of acute as well as chronic pancreatitis.

  12. Characteristics of a single bubble in subcooled boiling region of a narrow rectangular channel under natural circulation

    International Nuclear Information System (INIS)

    Zhou, Tao; Duan, Jun; Hong, Dexun; Liu, Ping; Sheng, Cheng; Huang, Yanping

    2013-01-01

    Highlights: ► We observe the behavior of single bubbles in a narrow vertical rectangular channel. ► We analyze the force characteristics of the single bubble. ► Small bubbles in highly subcooled boiling region stick on the wall or slip slowly. ► The bubbles jumping from the wall are affected by drag force. ► The thermophoretic force makes bubbles jump from the wall strongly. - Abstract: The behavior of bubbles has an important influence on heat transfer during subcooled boiling. By observing the behavior of a single bubble in a narrow vertical rectangular channel, and analyzing the force characteristics of the single bubble, it turns out that small bubbles in the highly subcooled boiling region stick on the wall or slip slowly. The bubbles jumping from the wall are affected by drag force, and move with high speed. Maintaining a certain heating power, at the onset of boiling (ONB) point, the bubbles remain in a stable state. Furthermore, the thermophoretic force is considered in this paper. With increasing the temperature gradient in the fluid, the thermophoretic force causes the bubbles to jump from the wall easier

  13. Threshold altitude for bubble decay and stabilization in rat adipose tissue at hypobaric exposures

    DEFF Research Database (Denmark)

    Randsoe, Thomas; Larsen, Ole Hyldegaard

    2013-01-01

    Bubble formation during altitude exposures, causing altitude decompression sickness (aDCS), has been referred to in theoretical models as venous gas embolisms (VGE). This has also been demonstrated by intravascular gas formation. Previous reports indicate that the formation of VGE and aDCS incide...

  14. Jet formation in shock-heavy gas bubble interaction

    Institute of Scientific and Technical Information of China (English)

    Zhi-Gang Zhai; Ting Si; Li-Yong Zou; Xi-Sheng Luo

    2013-01-01

    The influences of the acoustic impedance and shock strength on the jet formation in shock-heavy gas bubble interaction are numerically studied in this work.The process of a shock interacting with a krypton or a SF6 bubble is studied by the numerical method VAS2D.As a validation,the experiments of a SF6 bubble accelerated by a planar shock were performed.The results indicate that,due to the mismatch of acoustic impedance,the way of jet formation in heavy gas bubble with different species is diversified under the same initial condition.With respect to the same bubble,the manner of jet formation is also distinctly different under different shock strengths.The disparities of the acoustic impedance result in different effects of shock focusing in the bubble,and different behaviors of shock wave inside and outside the bubble.The analyses of the wave pattern and the pressure variation indicate that the jet formation is closely associated with the pressure perturbation.Moreover,the analysis of the vorticity deposition,and comparisons of circulation and baroclinic torque show that the baroclinic vorticity also contributes to the jet formation.It is concluded that the pressure perturbation and baroclinic vorticity deposition are the two dominant factors for the jet formation in shock-heavy gas bubble interaction.

  15. A postscript to Circulation of the blood: men and ideas.

    Science.gov (United States)

    Riley, R L

    1982-10-01

    Since 1964, when Fishman and Richards published Circulation of the Blood: Men and Ideas, Guyton's model of the circulation, in which mean circulatory pressure serves as the upstream pressure for venous return, has been extended, and the concept of vascular smooth muscle tone acting like the pressure surrounding a Starling resistor has been postulated. According to this scheme, the positive zero flow intercepts of rapidly determined arterial pressure-flow curves are the effective downstream pressures for arterial flow to different tissues. The arterioles, like Starling resistors, determine the downstream pressures and are followed by abrupt pressure drops, or "waterfalls." Capillary pressures are closely linked to those of the venules into which they flow. Capillary-venular pressures are the upstream pressures for venous return. In exercising muscles, reduced arteriolar tone lowers arteriolar pressure and increases arterial flow. This, in turn, raises capillary-venular pressure and increases venous flow. The arteriolar-capillary waterfall is decreased or eliminated. Total blood flow is increased by diversion of blood from tissues with slow venous drainage to muscles with fast venous drainage (low resistance X compliance). The heart pumps away the increased venous return by shifting to a new ventricular function curve.

  16. Numerical simulation on single bubble rising behavior in liquid metal using moving particle semi-implicit method

    International Nuclear Information System (INIS)

    Zuo Juanli; Tian Wenxi; Qiu Suizheng; Chen Ronghua; Su Guanghui

    2011-01-01

    The gas-lift pump in liquid metal cooling fast reactor (LMFR) is an innovational conceptual design to enhance the natural circulation ability of reactor core. The two-phase flow character of gas-liquid metal makes significant improvement of the natural circulation capacity and reactor safety. In present basic study, the rising behavior of a single nitrogen bubble in five kinds of liquid metals (lead bismuth alloy, liquid kalium, sodium, potassium sodium alloy and lithium lead alloy) was numerically simulated using moving particle semi-implicit (MPS) method. The whole growing process of single nitrogen bubble in liquid metal was captured. The bubble shape and rising speed of single nitrogen bubble in each liquid metal were compared. The comparison between simulation results using MPS method and Grace graphical correlation shows a good agreement. (authors)

  17. Convection in a volcanic conduit recorded by bubbles

    Science.gov (United States)

    Carey, Rebecca J.; Manga, Michael; Degruyter, Wim; Gonnermann, Helge M.; Swanson, Donald; Houghton, Bruce F.; Orr, Tim R.; Patrick, Matthew R.

    2013-01-01

    Microtextures of juvenile pyroclasts from Kīlauea’s (Hawai‘i) early A.D. 2008 explosive activity record the velocity and depth of convection within the basaltic magma-filled conduit. We use X-ray microtomography (μXRT) to document the spatial distribution of bubbles. We find small bubbles (radii from 5 μm to 70 μm) in a halo surrounding larger millimeter-size bubbles. This suggests that dissolved water was enriched around the larger bubbles—the opposite of what is expected if bubbles grow as water diffuses into the bubble. Such volatile enrichment implies that the volatiles within the large bubbles were redissolving into the melt as they descended into the conduit by the downward motion of convecting magma within the lava lake. The thickness of the small bubble halo is ∼100–150 μm, consistent with water diffusing into the melt on time scales on the order of 103 s. Eruptions, triggered by rockfall, rapidly exposed this magma to lower pressures, and the haloes of melt with re-dissolved water became sufficiently supersaturated to cause nucleation of the population of smaller bubbles. The required supersaturation pressures are consistent with a depth of a few hundred meters and convection velocities of the order of 0.1 m s−1, similar to the circulation velocity observed on the surface of the Halema‘uma‘u lava lake.

  18. The collateral venous system in late pregnancy: A systematic review of the literature.

    Science.gov (United States)

    Humphries, Aimee; Stone, Peter; Mirjalili, S Ali

    2017-11-01

    Recent literature has reported an association between maternal supine sleep position and stillbirth during late pregnancy. In this position the gravid uterus almost completely obstructs the inferior vena cava. A small number of women experience supine hypotension, thought to be due in part to inadequate collateral venous circulation. The aim of this paper is to review the literature describing the anatomy of the collateral venous system and in particular the azygos system, the abdominal portion of which has not been well studied. A systematic review was conducted using the electronic databases: Medline, Embase, Scopus, and Google Scholar. Relevant anatomical and radiological literature concerning the azygos system in particular was reviewed. The search was limited to adult human studies only. The collateral venous system can be divided into superficial, intermediate and deep systems. The azygos system in particular provides immediate collateral venous circulation in the event of acute inferior vena caval obstruction. The abdominal portion of this pathway, including the ascending lumbar vein, has not been well studied and there are certain variations that can render it ineffective. In conclusion, the collateral venous system provides an alternative route for blood to flow back to the systemic circulation when acute occlusion of the inferior vena cava occurs in the supine position during late pregnancy. However, certain anatomical variations can render this pathway ineffective, and this could have implications for the development of supine hypotension and stillbirth in late pregnancy. Clin. Anat. 30:1087-1095, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  19. [Correlation between indices of 24-h monitoring of blood pressure and disturbed venous cerebral outflow in hypertensive patients].

    Science.gov (United States)

    Afanas'eva, N L; Mordovin, V F; Semke, G V; Luk'ianenok, P I

    2008-01-01

    To study relations between disturbances of cerebral venous circulation and parameters of 24-h blood pressure monitoring in hypertensive patients. A total of 72 patients aged 28 to 60 years with essential hypertension of stage II have undergone 24-h blood pressure monitoring and MR-venography of the brachiocephalic veins on a low-field MR-tomograph using 2D TOF angiography. Symptoms of disturbed cerebral venous circulation were found in 60% patients. Major venous collectors were asymmetric in 79.2% patients, 40.3% had marked asymmetry, 14% had severe asymmetry. Disturbances of venous outflow significantly more frequently occurred in non-dippers and night-peakers as well as in high variability of blood pressure. Patients with marked asymmetry of venous collectors had elevated nocturnal systolic and diastolic blood pressure, high load indices of nocturnal systolic and diastolic pressure, a low degree of nocturnal fall of blood pressure. Disturbance of venous cerebral outflow in hypertensive patients is closely related with alterations of a circadian profile of blood pressure: circadian index of blood pressure, variability of blood pressure.

  20. THE AZYGOS VENOUS SYSTEM AND ITS ANATOMICAL VARIATIONS

    Directory of Open Access Journals (Sweden)

    Madiki Sudhakara Rao

    2016-06-01

    Full Text Available AIMS AND OBJECTIVES Azygos veins are important cavocaval and portacaval junctions, which form a collateral circulation in caval vein occlusion and in portal hypertension, cirrhosis of liver. The unpaired azygos venous system consists of azygos vein, hemiazygos vein and accessory azygos vein. This system of veins, along with its mediastinal, bronchial and oesophageal tributaries drains most of the body wall of trunk, namely posterior abdominal and thoracic wall. Anatomical variations of this unpaired azygos venous system are clinically important. AIMS To study and report the occurrence of anatomical variations of the unpaired azygos venous system in the region of East Godavari District, Andhra Pradesh (India. METHODS The present study was carried out in the Department of Anatomy, KIMS & RF, Amalapuram and G.S.L. Medical College, Rajahmundry over a period of 2 years. The present study was conducted on 60 cadavers (irrespective of age and sex. The entire course of the azygos venous system in these 60 cadavers was carefully observed and documented. RESULTS Anatomical variations were present in 16.66% of cases, out of which three distinct types were identified. 6.6% exhibited two separate azygos venous systems with no communications, 5% with communication between the left brachiocephalic vein and the azygos vein and 5% presence of post-aortic venous channels. CONCLUSION Variations of azygos venous system may be wrongly dubbed as aneurysm, lymphadenopathy or other abnormalities while reporting a CT scan of mediastinum. Venous anomalies are also detected only during surgery. The most troublesome intraoperative hazard is haemorrhage, which is mainly of venous origin. To avoid such situations is to have an awareness and knowledge of the expected venous anomalies.

  1. Development of an Accident Reproduction Simulator System Using a Hemodialysis Extracorporeal Circulation System

    Science.gov (United States)

    Nishite, Yoshiaki; Takesawa, Shingo

    2016-01-01

    Background: Accidents that occur during dialysis treatment are notified to the medical staff via alarms raised by the dialysis apparatus. Similar to such real accidents, apparatus activation or accidents can be reproduced by simulating a treatment situation. An alarm that corresponds to such accidents can be utilized in the simulation model. Objectives: The aim of this study was to create an extracorporeal circulation system (hereinafter, the circulation system) for dialysis machines so that it sets off five types of alarms for: 1) decreased arterial pressure, 2) increased arterial pressure, 3) decreased venous pressure, 4) increased venous pressure, and 5) blood leakage, according to the five types of accidents chosen based on their frequency of occurrence and the degree of severity. Materials and Methods: In order to verify the alarm from the dialysis apparatus connected to the circulation system and the accident corresponding to it, an evaluation of the alarm for its reproducibility of an accident was performed under normal treatment circumstances. The method involved testing whether the dialysis apparatus raised the desired alarm from the moment of control of the circulation system, and measuring the time it took until the desired alarm was activated. This was tested on five main models from four dialyzer manufacturers that are currently used in Japan. Results: The results of the tests demonstrated successful activation of the alarms by the dialysis apparatus, which were appropriate for each of the five types of accidents. The time between the control of the circulatory system to the alarm signal was as follows, 1) venous pressure lower limit alarm: 7 seconds; 2) venous pressure lower limit: 8 seconds; 3) venous pressure upper limit: 7 seconds; 4) venous pressure lower limit alarm: 2 seconds; and 5) blood leakage alarm: 19 seconds. All alarms were set off in under 20 seconds. Conclusions: Thus, we can conclude that a simulator system using an extracorporeal

  2. PIV Visualization of Bubble Induced Flow Circulation in 2-D Rectangular Pool for Ex-Vessel Debris Bed Coolability

    Energy Technology Data Exchange (ETDEWEB)

    Han, Teayang; Kim, Eunho; Park, Hyun Sun; Moriyama, Kiyofumi [POSTECH, Pohang (Korea, Republic of)

    2015-10-15

    The previous research works demonstrated the debris bed formation on the flooded cavity floor in experiments. Even in the cases the core melt is once solidified, the debris bed can be re-melted due to the decay heat. If the debris bed is not cooled enough by the coolant, the re-melted debris bed will react with the concrete base mat. This situation is called the molten core-concrete interaction (MCCI) which threatens the integrity of the containment by generated gases which pressurize the containment. Therefore securing the long term coolability of the debris bed in the cavity is crucial. According to the previous research works, the natural convection driven by the rising bubbles affects the coolability and the formation of the debris bed. Therefore, clarification of the natural convection characteristics in and around the debris bed is important for evaluation of the coolability of the debris bed. In this study, two-phase flow around the debris bed in a 2D slice geometry is visualized by PIV method to obtain the velocity map of the flow. The DAVINCI-PIV was developed to investigate the flow around the debris bed. In order to simulate the boiling phenomena induced by the decay heat of the debris bed, the air was injected separately by the air chamber system which consists of the 14 air-flowmeters. The circulation flow developed by the rising bubbles was visualized by PIV method.

  3. Bubble dynamics and bubble-induced turbulence of a single-bubble chain

    Science.gov (United States)

    Lee, Joohyoung; Park, Hyungmin

    2016-11-01

    In the present study, the bubble dynamics and liquid-phase turbulence induced by a chain of bubbles injected from a single nozzle have been experimentally investigated. Using a high-speed two-phase particle image velociemtry, measurements on the bubbles and liquid-phase velocity field are conducted in a transparent tank filled with water, while varying the bubble release frequency from 0.1 to 35 Hz. The tested bubble size ranges between 2.0-3.2 mm, and the corresponding bubble Reynolds number is 590-1100, indicating that it belongs to the regime of path instability. As the release frequency increases, it is found that the global shape of bubble dispersion can be classified into two regimes: from asymmetric (regular) to axisymmetric (irregular). In particular, at higher frequency, the wake vortices of leading bubbles cause an irregular behaviour of the following bubble. For the liquid phase, it is found that a specific trend on the bubble-induced turbulence appears in a strong relation to the above bubble dynamics. Considering this, we try to provide a theoretical model to estimate the liquid-phase turbulence induced by a chain of bubbles. Supported by a Grant funded by Samsung Electronics, Korea.

  4. Epidural venous stasis in spinal stenosis

    International Nuclear Information System (INIS)

    Kaiser, M.C.; Capesius, P.; Poos, D.; Gratia, G.; Roilgen, A.; Sandt, G.

    1984-01-01

    Computed tomography permits reliable demonstration of the spinal canal and its contents. Measurements of the sagittal diameter of the bony canal do not take into consideration size, shape and state of intraspinal soft tissue structures, i.e. the thecal sac and its own contents, epidural fat and blood circulation pattern. Three particularly illustrative cases were selected in which obvious epidural venous engorgement was visualized in association with spinal stenosis. The authors think that epidural venous stasis occuring in segmental spinal stenosis is a CT sign of clinically significant narrowing of the neural canal. Accurate recognition of the type of lumbar stenosis together with epidural blood flow alterations permits a better understanding of the existing lesions. Thus, a more precise and specific surgical approach is possible. (orig.)

  5. Research on enhancement of natural circulation capability in lead–bismuth alloy cooled reactor by using gas-lift pump

    Energy Technology Data Exchange (ETDEWEB)

    Zuo, Juanli, E-mail: Jenyzuo@163.com; Tian, Wenxi, E-mail: wxtian@mail.xjtu.edu.cn; Chen, Ronghua, E-mail: ronghua.chen@stu.xjtu.edu.cn; Qiu, Suizheng; Su, Guanghui, E-mail: ghsu@mail.xjtu.edu.cn

    2013-10-15

    Highlights: • The gas-lift pump has been adopted to enhance the natural circulation capability. • LENAC code is developed in my study. • The calculation results by LENAC code show good agreement with experiment results. • Gas mass flow rate, bubble diameter, rising pipe length are important parameters. -- Abstract: The gas-lift pump has been adopted to enhance the natural circulation capability in the type of lead–bismuth alloy cooled reactors such as Accelerator Driven System (ADS) and Liquid–metal Fast Reactor (LMFR). The natural circulation ability and the system safety are obviously influenced by the two phase flow characteristics of liquid metal–inert gas. In this study, LENAC (LEad bismuth alloy NAtural Circulation capability) code has been developed to evaluate the natural circulation capability of lead–bismuth cooled ADS with gas-lift pump. The drift flow theory, void fraction prediction model and friction pressure drop prediction model have been incorporated into LENAC code. The calculation results by LENAC code show good agreement with experiment results of CIRCulation Experiment (CIRCE) facility. The effects of the gas mass flow rate, void fraction, gas quality, bubble diameter and the rising pipe height or the potential difference between heat exchanger and reactor core on natural circulation capability of gas-lift pump have been analyzed. The results showed that in bubbly flow pattern, for a fixed value of gas mass flow rate, the natural circulation capability increased with the decrease of the bubble diameter. In the bubbly flow, slug flow, churn flow and annular flow pattern, with the gas mass flow rate increasing, the natural circulation capability initially increased and then declined. And the flow parameters influenced the thermal hydraulic characteristics of the reactor core significantly. The present work is helpful for revealing the law of enhancing the natural circulation capability by gas-lift pump, and providing theoretical

  6. Assessment of liver circulation by quantitative scintiangiography: Evaluation of the relative contribution of the hepatic arterial and portal venous blood flows to liver perfusion

    International Nuclear Information System (INIS)

    Molino, G.; Squadrone, E.; Baccegal, M.; Magnani, C.

    1989-01-01

    Quantitative hepatic scintiangiography was previously used for evaluating the relative contribution of hepatic arterial and portal venous blood flows to the hepatic circulation. The present study compares 3 different procedures (automatic and manual integration, and slope fitting methods) for analyzing the hepatic time activity curves obtained after bolus i.v. injection of 370 MBq 99m Tc-diethylentriaminopentacetic acid. Twenty five subjects were studied: Five controls, ten cirrhotics, and ten portal hypertensive patients previously submitted to side to side portacaval anastomosis. The correspondence between results given by the different methods was satisfactory only in shunted patients, and the reproducibility of computed parameters was quite poor for all procedures. Accordingly, none of the methods can be considered as supporting reliable quantitative pathophysiological evaluations. However, the hepatic arterial/portal venous flow ratio was found to be increased in liver cirrhosis and in shunted patients and therefore, in spite of the limitations underlined before and of the absence of data on the reproducibility of consecutive injections, hepatic scintiangiography may be of some clinical utility. (orig.)

  7. Anomlus pulmonary venous return aaccompanied by normal superior pulmonary veins in the left upper lobe: A case report

    International Nuclear Information System (INIS)

    Kim, Dong Eon; Kang, Min Jin; Lee, Ji Hae; Bae, Kyung Eun; Kim, Jae Hyung; Kang, Tae Kyung; Kim, Soung Hee; Kim, Ji Young; Jeong, Myeong Ja; Kim, Soo Hyun

    2017-01-01

    Partial anomalous pulmonary venous return is a rare congenital pulmonary venous anomaly, in which some of the pulmonary veins drain into the systemic circulation rather than the left atrium. Many variants of partial anomalous pulmonary venous return have been reported. We present a rare type of partial anomalous pulmonary venous return in which the anomalous left upper lobe pulmonary vein drained into the left innominate vein via the vertical vein, accompanying the left upper lobe pulmonary vein in the normal location

  8. Anomlus pulmonary venous return aaccompanied by normal superior pulmonary veins in the left upper lobe: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Eon; Kang, Min Jin; Lee, Ji Hae; Bae, Kyung Eun; Kim, Jae Hyung; Kang, Tae Kyung; Kim, Soung Hee; Kim, Ji Young; Jeong, Myeong Ja; Kim, Soo Hyun [Sanggye Paik Hospital, Inje University College of Medicine, Seoul (Korea, Republic of)

    2017-08-15

    Partial anomalous pulmonary venous return is a rare congenital pulmonary venous anomaly, in which some of the pulmonary veins drain into the systemic circulation rather than the left atrium. Many variants of partial anomalous pulmonary venous return have been reported. We present a rare type of partial anomalous pulmonary venous return in which the anomalous left upper lobe pulmonary vein drained into the left innominate vein via the vertical vein, accompanying the left upper lobe pulmonary vein in the normal location.

  9. A blood circulation model for reference man

    Energy Technology Data Exchange (ETDEWEB)

    Leggett, R.W.; Eckerman, K.F. [Oak Ridge National Lab., TN (United States); Williams, L.R. [Indiana Univ., South Bend, IN (United States). Div. of Liberal Arts and Sciences

    1996-12-31

    A dynamic blood circulation model that predicts the movement and gradual dispersion of a bolus of material in the circulation after its intravenous injection into an adult human. The main purpose of the model is improve the dosimetry of internally deposited radionuclides that decay in the circulation to a significant extent. The model partitions the blood volume into 24 separate organs or tissues, right heart chamber, left heart chamber, pulmonary circulation, arterial outflow to the aorta and large arteries, and venous return via the large veins. Model results were compared to data obtained from injection of carbon 11 labeled carbon monoxide or rubidium 86.

  10. A blood circulation model for reference man

    International Nuclear Information System (INIS)

    Leggett, R.W.; Eckerman, K.F.; Williams, L.R.

    1996-01-01

    A dynamic blood circulation model that predicts the movement and gradual dispersion of a bolus of material in the circulation after its intravenous injection into an adult human. The main purpose of the model is improve the dosimetry of internally deposited radionuclides that decay in the circulation to a significant extent. The model partitions the blood volume into 24 separate organs or tissues, right heart chamber, left heart chamber, pulmonary circulation, arterial outflow to the aorta and large arteries, and venous return via the large veins. Model results were compared to data obtained from injection of carbon 11 labeled carbon monoxide or rubidium 86

  11. Bubble and boundary layer behaviour in subcooled flow boiling

    Energy Technology Data Exchange (ETDEWEB)

    Maurus, Reinhold; Sattelmayer, Thomas [Lehrstuhl fuer Thermodynamik, Technische Universitaet Muenchen, 85747 Garching (Germany)

    2006-03-15

    Subcooled flow boiling is a commonly applied technique for achieving efficient heat transfer. In the study, an experimental investigation in the nucleate boiling regime was performed for water circulating in a closed loop at atmospheric pressure. The horizontal orientated test-section consists of a rectangular channel with a one side heated copper strip and good optical access. Various optical observation techniques were applied to study the bubble behaviour and the characteristics of the fluid phase. The bubble behaviour was recorded by the high-speed cinematography and by a digital high resolution camera. Automated image processing and analysis algorithms developed by the authors were applied for a wide range of mass flow rates and heat fluxes in order to extract characteristic length and time scales of the bubbly layer during the boiling process. Using this methodology, the bubbles were automatically analysed and the bubble size, bubble lifetime, waiting time between two cycles were evaluated. Due to the huge number of observed bubbles a statistical analysis was performed and distribution functions were derived. Using a two-dimensional cross-correlation algorithm, the averaged axial phase boundary velocity profile could be extracted. In addition, the fluid phase velocity profile was characterised by means of the particle image velocimetry (PIV) for the single phase flow as well as under subcooled flow boiling conditions. The results indicate that the bubbles increase the flow resistance. The impact on the flow exceeds by far the bubbly region and it depends on the magnitude of the boiling activity. Finally, the ratio of the averaged phase boundary velocity and of the averaged fluid velocity was evaluated for the bubbly region. (authors)

  12. Self-assembling bubble carriers for oral protein delivery.

    Science.gov (United States)

    Chuang, Er-Yuan; Lin, Kun-Ju; Lin, Po-Yen; Chen, Hsin-Lung; Wey, Shiaw-Pyng; Mi, Fwu-Long; Hsiao, Hsu-Chan; Chen, Chiung-Tong; Sung, Hsing-Wen

    2015-09-01

    Successful oral delivery of therapeutic proteins such as insulin can greatly improve the quality of life of patients. This study develops a bubble carrier system by loading diethylene triamine pentaacetic acid (DTPA) dianhydride, a foaming agent (sodium bicarbonate; SBC), a surfactant (sodium dodecyl sulfate; SDS), and a protein drug (insulin) in an enteric-coated gelatin capsule. Following oral administration to diabetic rats, the intestinal fluid that has passed through the gelatin capsule saturates the mixture; concomitantly, DTPA dianhydride produces an acidic environment, while SBC decomposes to form CO2 bubbles at acidic pH. The gas bubbles grow among the surfactant molecules (SDS) owing to the expansion of the generated CO2. The walls of the CO2 bubbles consist of a self-assembled film of water that is in nanoscale and may serve as a colloidal carrier to transport insulin and DTPA. The grown gas bubbles continue to expand until they bump into the wall and burst, releasing their transported insulin, DTPA, and SDS into the mucosal layer. The released DTPA and SDS function as protease inhibitors to protect the insulin molecules as well as absorption enhancers to augment their epithelial permeability and eventual absorption into systemic circulation, exerting their hypoglycemic effects. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Theory calculation of combination of 'embryo' bubble growing-up visible bubble in bubble chamber

    International Nuclear Information System (INIS)

    Ye Zipiao; Sheng Xiangdong; Dai Changjiang

    2004-01-01

    By aid of island combination theory of 'embryo' bubble, it is resolved well the question which 'embryo' bubble grows up a visible bubble in the bubble chamber. Through theory calculation it is shown that radius of the big' embryo' bubble combinated not only relates with work matter such as surface tension coefficient, saturation vapour pressure and boiling point of liquid, but also does absorbing quantity of heat and the numbers of 'embryo' bubbles combination. It is explained reasonably that the radius of bubbles in bubble chamber is different for the same energies of neutrons and proton. The track of neutron in bubble chamber is long and thin, and the track of proton in bubble chamber is wide and short. It is also explained reasonably that the bubble radius of the incident particles with more charges which there are the same energies will be wider than that of the incident particles with less charges in the track. (author)

  14. Bubble-cell interactions with laser-activated polymeric microcapsules

    Science.gov (United States)

    Versluis, Michel; Lajoinie, Guillaume; van Rooij, Tom; Skachkov, Ilya; Kooiman, Klazina; de Jong, Nico; Physics of Fluids Group, University of Twente Team; Biomedical Engineering, Erasmus MC Team

    2015-11-01

    Polymeric microcapsules that are made light-absorbing by the addition of a dye in their shell can generate cavitation microbubbles with spatiotemporal control when irradiated by a pulsed laser. These particles less than 3 μm in size can circulate through the body, bind to tissues and are expected to be readily detected, even if a single cavitation bubble is produced. In this paper, we study the impact of such cavitation bubbles on a cell monolayer and quantify it in terms of cell poration and cell viability. Two capsules formulations were used; the first one encapsulates a low boiling point oil and induced less cell damage than the second that was loaded with a high boiling point oil. We also report the generation of stable bubbles by the first capsule formulation that completely absorb the cells in their close vicinity. Physics of Fluid group MIRA Institute for Biomedical Technology and Technical Medicine MESA+ Institute for Nanotechnology.

  15. Size distribution of air bubbles entering the brain during cardiac surgery.

    Directory of Open Access Journals (Sweden)

    Emma M L Chung

    Full Text Available Thousands of air bubbles enter the cerebral circulation during cardiac surgery, but whether high numbers of bubbles explain post-operative cognitive decline is currently controversial. This study estimates the size distribution of air bubbles and volume of air entering the cerebral arteries intra-operatively based on analysis of transcranial Doppler ultrasound data.Transcranial Doppler ultrasound recordings from ten patients undergoing heart surgery were analysed for the presence of embolic signals. The backscattered intensity of each embolic signal was modelled based on ultrasound scattering theory to provide an estimate of bubble diameter. The impact of showers of bubbles on cerebral blood-flow was then investigated using patient-specific Monte-Carlo simulations to model the accumulation and clearance of bubbles within a model vasculature.Analysis of Doppler ultrasound recordings revealed a minimum of 371 and maximum of 6476 bubbles entering the middle cerebral artery territories during surgery. This was estimated to correspond to a total volume of air ranging between 0.003 and 0.12 mL. Based on analysis of a total of 18667 embolic signals, the median diameter of bubbles entering the cerebral arteries was 33 μm (IQR: 18 to 69 μm. Although bubble diameters ranged from ~5 μm to 3.5 mm, the majority (85% were less than 100 μm. Numerous small bubbles detected during cardiopulmonary bypass were estimated by Monte-Carlo simulation to be benign. However, during weaning from bypass, showers containing large macro-bubbles were observed, which were estimated to transiently affect up to 2.2% of arterioles.Detailed analysis of Doppler ultrasound data can be used to provide an estimate of bubble diameter, total volume of air, and the likely impact of embolic showers on cerebral blood flow. Although bubbles are alarmingly numerous during surgery, our simulations suggest that the majority of bubbles are too small to be harmful.

  16. Bubbles

    DEFF Research Database (Denmark)

    Dholakia, Nikhilesh; Turcan, Romeo V.

    2013-01-01

    A goal of our ongoing research stream is to develop a multidisciplinary metatheory of bubbles. In this viewpoint paper we put forward a typology of bubbles by comparing four types of assets – entertainment, commodities, financial securities (stocks), and housing properties – where bubbles could...... and do form occasionally. Cutting across and comparing such varied asset types provides some rich insights into the nature of bubbles – and offers an inductive way to arrive at the typology of bubbles....

  17. Arterial supply, venous drainage and collateral circulation in the nose of the anaesthetized dog.

    Science.gov (United States)

    Lung, M A; Wang, J C

    1987-01-01

    1. In pentobarbitone-anaesthetized dogs, nasal blood flows were measured with electromagnetic flow sensors. 2. The terminal internal maxillary artery was found to supply 22 +/- 2.2 ml min-1 (one side) to the nasal mucosa via the sphenopalatine and major palatine branches; the artery was found to receive multiple supply routes from common carotid, vertebral and subclavian arteries. 3. Nasal mucosa was found to receive collateral flow from contralateral terminal internal maxillary artery (about 5 to 10% of normal flow) and branches of subclavian arteries (about 36% of normal flow). 4. Nasal mucosa was found to have two venous systems: the low-flow (12 +/- 1.0 ml min-1; both sides) and low-pressure (7 +/- 0.6 mmHg) sphenopalatine veins draining the posterior nasal cavity and the high-flow (30 +/- 1.4 ml min-1; both sides) and high-pressure (17 +/- 1.0 mmHg) dorsal nasal veins draining the anterior nasal cavity. 5. PO2 of nasal venous blood was found to range from 62 +/- 2.9 mmHg to 65 +/- 3.4 mmHg. During nitrogen challenge to the nose, the sphenopalatine venous PO2 dropped to 35 +/- 3.0 mmHg while the dorsal nasal venous PO2 remained unchanged, suggesting that the sphenopalatine veins were responsible for draining capillary flow and dorsal nasal veins arteriovenous anastomotic flow as well. 6. Microscopic examination of the vascular casts confirmed that arteriovenous anastomoses were located only in the anterior nasal cavity. Images Fig. 5 Plate 1 Plate 2 PMID:3443958

  18. Bubbles generated from wind-steepened breaking waves: 1. Bubble plume bubbles

    NARCIS (Netherlands)

    Leifer, I.; Leeuw, G. de

    2006-01-01

    Measurements of bubble plumes from paddle-amplified, wind stress breaking waves were made in a large wind-wave channel during the LUMINY experiment in fresh (but not clean) water. Bubble plumes exhibited considerable variability with respect to dynamics, bubble size distribution, and physical

  19. Heat transport in bubbling turbulent convection.

    Science.gov (United States)

    Lakkaraju, Rajaram; Stevens, Richard J A M; Oresta, Paolo; Verzicco, Roberto; Lohse, Detlef; Prosperetti, Andrea

    2013-06-04

    Boiling is an extremely effective way to promote heat transfer from a hot surface to a liquid due to numerous mechanisms, many of which are not understood in quantitative detail. An important component of the overall process is that the buoyancy of the bubble compounds with that of the liquid to give rise to a much-enhanced natural convection. In this article, we focus specifically on this enhancement and present a numerical study of the resulting two-phase Rayleigh-Bénard convection process in a cylindrical cell with a diameter equal to its height. We make no attempt to model other aspects of the boiling process such as bubble nucleation and detachment. The cell base and top are held at temperatures above and below the boiling point of the liquid, respectively. By keeping this difference constant, we study the effect of the liquid superheat in a Rayleigh number range that, in the absence of boiling, would be between 2 × 10(6) and 5 × 10(9). We find a considerable enhancement of the heat transfer and study its dependence on the number of bubbles, the degree of superheat of the hot cell bottom, and the Rayleigh number. The increased buoyancy provided by the bubbles leads to more energetic hot plumes detaching from the cell bottom, and the strength of the circulation in the cell is significantly increased. Our results are in general agreement with recent experiments on boiling Rayleigh-Bénard convection.

  20. Anti-Bubbles

    Science.gov (United States)

    Tufaile, Alberto; Sartorelli, José Carlos

    2003-08-01

    An anti-bubble is a striking kind of bubble in liquid that seemingly does not comply the buoyancy, and after few minutes it disappears suddenly inside the liquid. Different from a simple air bubble that rises directly to the liquid surface, an anti-bubble wanders around in the fluid due to its slightly lesser density than the surrounding liquid. In spite of this odd behavior, an anti-bubble can be understood as the opposite of a conventional soap bubble in air, which is a shell of liquid surrounding air, and an anti-bubble is a shell of air surrounding a drop of the liquid inside the liquid. Two-phase flow has been a subject of interest due to its relevance to process equipment for contacting gases and liquids applied in industry. A chain of bubbles rising in a liquid formed from a nozzle is a two-phase flow, and there are certain conditions in which spherical air shells, called anti-bubbles, are produced. The purpose of this work is mainly to note the existence of anti-bubbling regime as a sequel of a bubbling system. We initially have presented the experimental apparatus. After this we have described the evolution of the bubbling regimes, and emulated the effect of bubbling coalescence with simple maps. Then is shown the inverted dripping as a consequence of the bubble coalescence, and finally the conditions for anti-bubble formation.

  1. Bubble properties of heterogeneous bubbly flow in a square bubble column

    NARCIS (Netherlands)

    Bai, Wei; Deen, Niels G.; Kuipers, J.A.M.

    2010-01-01

    The present work focuses on the measurements of bubble properties in heterogeneous bubbly flows in a square bubble column. A four-point optical fibre probe was used for this purpose. The accuracy and intrusive effect of the optical probe was investigated first. The results show that the optical

  2. Effects of abdominal pressure on venous return: abdominal vascular zone conditions.

    Science.gov (United States)

    Takata, M; Wise, R A; Robotham, J L

    1990-12-01

    The effects of changes in abdominal pressure (Pab) on inferior vena cava (IVC) venous return were analyzed using a model of the IVC circulation based on a concept of abdominal vascular zone conditions analogous to pulmonary vascular zone conditions. We hypothesized that an increase in Pab would increase IVC venous return when the IVC pressure at the level of the diaphragm (Pivc) exceeds the sum of Pab and the critical closing transmural pressure (Pc), i.e., zone 3 conditions, but reduce IVC venous return when Pivc is below the sum of Pab and Pc, i.e., zone 2 conditions. The validity of the model was tested in 12 canine experiments with an open-chest IVC bypass. An increase in Pab produced by phrenic stimulation increased the IVC venous return when Pivc-Pab was positive but decreased the IVC venous return when Pivc - Pab was negative. The value of Pivc - Pab that separated net increases from decreases in venous return was 1.00 +/- 0.72 (SE) mmHg (n = 6). An increase in Pivc did not influence the femoral venous pressure when Pivc was lower than the sum of Pab and a constant, 0.96 +/- 0.70 mmHg (n = 6), consistent with presence of a waterfall. These results agreed closely with the predictions of the model and its computer simulation. The abdominal venous compartment appears to function with changes in Pab either as a capacitor in zone 3 conditions or as a collapsible Starling resistor with little wall tone in zone 2 conditions.

  3. Filamentary Alfvénic structures excited at the edges of equatorial plasma bubbles

    Directory of Open Access Journals (Sweden)

    R. Pottelette

    2007-11-01

    Full Text Available Recent observations performed by the French DEMETER satellite at altitudes of about 710 km suggest that the generation of equatorial plasma bubbles correlates with the presence of filamentary structures of field aligned currents carried by Alfvén waves. These localized structures are located at the bubble edges. We study the dynamics of the equatorial plasma bubbles, taking into account that their motion is dictated by gravity driven and displacement currents. Ion-polarization currents appear to be crucial for the accurate description of the evolution of plasma bubbles in the high altitude ionosphere. During their eastward/westward motion the bubbles intersect gravity driven currents flowing transversely with respect to the background magnetic field. The circulation of these currents is prohibited by large density depressions located at the bubble edges acting as perfect insulators. As a result, in these localized regions the transverse currents have to be locally closed by field aligned currents. Such a physical process generates kinetic Alfvén waves which appear to be stationary in the plasma bubble reference frame. Using a two-dimensional model and "in situ" wave measurements on board the DEMETER spacecraft, we give estimates for the magnitude of the field aligned currents and the associated Alfvén fields.

  4. CT portal venography manifestations of portal collateral circulation in patients with portal hypertension due to cirrhosis

    International Nuclear Information System (INIS)

    Ni Ming; Lv Weifu; Deng Kexue

    2009-01-01

    Objective: To analyze CT portal venography (CTPV) manifestations of portal collateral circulation in patients with cirrhosis by using a 16-detector row spiral CT scanner. Methods: CTPV was performed in 36 patients with portal hypertension due to cirrhosis, the diagnosis was proved by clinical data, hepatic function findings and imaging signs. By using post-processing reconstruction technique, 3D images of portal venous system and portal collateral circulation were obtained. Results: CTPV images displayed the portal venous system and its collateral circulation stereoscopically. Of 36 patients, left gastric varices were seen in 29(80.6%), lower esophageal varices in 18(50.0%), short gastric or posterior gastric varices in 15(41.7%), paraesophageal varices in 9(25.0%), gastro-renal or splenorenal shunts in 8(22.2%), spongelike transformation of portal vein in 7(19.4%), paraumbilical and abdominal wall varices in 6(16.7%), congenital cavernous in 6(16.7%) and paravertebral venous shunts in 4(11.1%). Conclusion: CTPV can well display the site, extent and severity of the portal collateral circulation in patients with portal hypertension due to cirrhosis,which is of great clinical importance for judging the patient's condition, for selecting therapeutic protocols and for estimating prognosis. (authors)

  5. Freezing Bubbles

    Science.gov (United States)

    Kingett, Christian; Ahmadi, Farzad; Nath, Saurabh; Boreyko, Jonathan

    2017-11-01

    The two-stage freezing process of a liquid droplet on a substrate is well known; however, how bubbles freeze has not yet been studied. We first deposited bubbles on a silicon substrate that was chilled at temperatures ranging from -10 °C to -40 °C, while the air was at room temperature. We observed that the freeze front moved very slowly up the bubble, and in some cases, even came to a complete halt at a critical height. This slow freezing front propagation can be explained by the low thermal conductivity of the thin soap film, and can be observed more clearly when the bubble size or the surface temperature is increased. This delayed freezing allows the frozen portion of the bubble to cool the air within the bubble while the top part is still liquid, which induces a vapor pressure mismatch that either collapses the top or causes the top to pop. In cases where the freeze front reaches the top of the bubble, a portion of the top may melt and slowly refreeze; this can happen more than just once for a single bubble. We also investigated freezing bubbles inside of a freezer where the air was held at -20 °C. In this case, the bubbles freeze quickly and the ice grows radially from nucleation sites instead of perpendicular to the surface, which provides a clear contrast with the conduction limited room temperature bubbles.

  6. Science Bubbles

    DEFF Research Database (Denmark)

    Hendricks, Vincent Fella; Pedersen, David Budtz

    2013-01-01

    Much like the trade and trait sof bubbles in financial markets,similar bubbles appear on the science market. When economic bubbles burst, the drop in prices causes the crash of unsustainable investments leading to an investor confidence crisis possibly followed by a financial panic. But when...... bubbles appear in science, truth and reliability are the first victims. This paper explores how fashions in research funding and research management may turn science into something like a bubble economy....

  7. Caudal venous return through a left azygos vein in a dog

    International Nuclear Information System (INIS)

    Sammarco, C.D.; Regan, J.; Ward, C.R.; Buchanan, J.D.

    1995-01-01

    The Clinical, radiologic and echocardiographic findings in a one-year old dog with mild subvalvular aortic stenosis and aberrant caudal vena circulation are described. Aberrant systemic venous return to the right side of the heart usually has little clinical significance, but the unusual features in survey radiographs, contrast angiograms and contrast echocardiograms constitute the reasons for this report

  8. Cholesterol delivery to the adrenal glands estimated by adrenal venous sampling: An in vivo model to determine the contribution of circulating lipoproteins to steroidogenesis in humans.

    Science.gov (United States)

    Buitenwerf, Edward; Dullaart, Robin P F; Muller Kobold, Anneke C; Links, Thera P; Sluiter, Wim J; Connelly, Margery A; Kerstens, Michiel N

    Cholesterol, required for adrenal steroid hormone synthesis, is at least in part derived from circulating lipoproteins. The contribution of high-density lipoproteins (HDL) and low-density lipoproteins (LDL) to adrenal steroidogenesis in humans is unclear. The aim of the study was to determine the extent to which HDL and LDL are taken up by the adrenal glands using samples obtained during adrenal venous sampling (AVS). AVS was successfully performed in 23 patients with primary aldosteronism. Samples were drawn from both adrenal veins and inferior vena cava (IVC). HDL cholesterol (HDL-C) and lipoprotein particle profiles were determined by nuclear magnetic resonance spectroscopy. Apolipoprotein (apo) A-I and apoB were assayed by immunoturbidimetry. Plasma HDL-C and HDL and LDL particle concentrations (HDL-P and LDL-P) were not lower in samples obtained from the adrenal veins compared with the IVC (HDL-C, P = .59; HDL-P, P = .06; LDL-P, P = .93). ApoB was lower in adrenal venous plasma than in IVC (P = .026; P lipoproteins and steroidogenesis. Copyright © 2017 National Lipid Association. Published by Elsevier Inc. All rights reserved.

  9. Characteristics of bubble plumes, bubble-plume bubbles and waves from wind-steepened wave breaking

    NARCIS (Netherlands)

    Leifer, I.; Caulliez, G.; Leeuw, G. de

    2007-01-01

    Observations of breaking waves, associated bubble plumes and bubble-plume size distributions were used to explore the coupled evolution of wave-breaking, wave properties and bubble-plume characteristics. Experiments were made in a large, freshwater, wind-wave channel with mechanical wind-steepened

  10. Optoacoustic monitoring of central and peripheral venous oxygenation during simulated hemorrhage

    Science.gov (United States)

    Petrov, Andrey; Kinsky, Michael; Prough, Donald S.; Petrov, Yuriy; Petrov, Irene Y.; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Khan, Muzna N.; Esenaliev, Rinat O.

    2014-03-01

    Circulatory shock may be fatal unless promptly recognized and treated. The most commonly used indicators of shock (hypotension and tachycardia) lack sensitivity and specificity. In the initial stages of shock, the body compensates by reducing blood flow to the peripheral (skin, muscle, etc.) circulation in order to preserve vital organ (brain, heart, liver) perfusion. Characteristically, this can be observed by a greater reduction in peripheral venous oxygenation (for instance, the axillary vein) compared to central venous oxygenation (the internal jugular vein). While invasive measurements of oxygenation are accurate, they lack practicality and are not without complications. We have developed a novel optoacoustic system that noninvasively determines oxygenation in specific veins. In order to test this application, we used lower body negative pressure (LBNP) system, which simulates hemorrhage by exerting a variable amount of suction on the lower body, thereby reducing the volume of blood available for central circulation. Restoration of normal blood flow occurs promptly upon cessation of LBNP. Using two optoacoustic probes, guided by ultrasound imaging, we simultaneously monitored oxygenation in the axillary and internal jugular veins (IJV). LBNP began at -20 mmHg, thereafter was reduced in a step-wise fashion (up to 30 min). The optoacoustically measured axillary oxygenation decreased with LBNP, whereas IJV oxygenation remained relatively constant. These results indicate that our optoacoustic system may provide safe and rapid measurement of peripheral and central venous oxygenation and diagnosis of shock with high specificity and sensitivity.

  11. Management of venous leg ulcers in general practice - a practical guideline.

    Science.gov (United States)

    Sinha, Sankar; Sreedharan, Sadhishaan

    2014-09-01

    Chronic venous leg ulcers are the most common wounds seen in general practice. Their management can be both challenging and time-consuming. To produce a short practical guideline incorporating the TIME concept and A2BC2D approach to help general practitioners and their practice nurses in delivering evidence-based initial care to patients with chronic venous leg ulcers. Most chronic venous leg ulcers can be managed effectively in the general practice setting by following the simple, evidence-based approach described in this article. Figure 1 provides a flow chart to aid in this process. Figure 2 illustrates the principles of management in general practice. Effective management of chronic ulcers involves the assessment of both the ulcer and the patient. The essential requirements of management are to debride the ulcer with appropriate precautions, choose dressings that maintain adequate moisture balance, apply graduated compression bandage after evaluation of the arterial circulation and address the patient's concerns, such as pain and offensive wound discharge.

  12. Automated high-speed video analysis of the bubble dynamics in subcooled flow boiling

    Energy Technology Data Exchange (ETDEWEB)

    Maurus, Reinhold; Ilchenko, Volodymyr; Sattelmayer, Thomas [Technische Univ. Muenchen, Lehrstuhl fuer Thermodynamik, Garching (Germany)

    2004-04-01

    Subcooled flow boiling is a commonly applied technique for achieving efficient heat transfer. In the study, an experimental investigation in the nucleate boiling regime was performed for water circulating in a closed loop at atmospheric pressure. The test-section consists of a rectangular channel with a one side heated copper strip and a very good optical access. For the optical observation of the bubble behaviour the high-speed cinematography is used. Automated image processing and analysis algorithms developed by the authors were applied for a wide range of mass flow rates and heat fluxes in order to extract characteristic length and time scales of the bubbly layer during the boiling process. Using this methodology, a huge number of bubble cycles could be analysed. The structure of the developed algorithms for the detection of the bubble diameter, the bubble lifetime, the lifetime after the detachment process and the waiting time between two bubble cycles is described. Subsequently, the results from using these automated procedures are presented. A remarkable novelty is the presentation of all results as distribution functions. This is of physical importance because the commonly applied spatial and temporal averaging leads to a loss of information and, moreover, to an unjustified deterministic view of the boiling process, which exhibits in reality a very wide spread of bubble sizes and characteristic times. The results show that the mass flux dominates the temporal bubble behaviour. An increase of the liquid mass flux reveals a strong decrease of the bubble life - and waiting time. In contrast, the variation of the heat flux has a much smaller impact. It is shown in addition that the investigation of the bubble history using automated algorithms delivers novel information with respect to the bubble lift-off probability. (Author)

  13. Automated high-speed video analysis of the bubble dynamics in subcooled flow boiling

    International Nuclear Information System (INIS)

    Maurus, Reinhold; Ilchenko, Volodymyr; Sattelmayer, Thomas

    2004-01-01

    Subcooled flow boiling is a commonly applied technique for achieving efficient heat transfer. In the study, an experimental investigation in the nucleate boiling regime was performed for water circulating in a closed loop at atmospheric pressure. The test-section consists of a rectangular channel with a one side heated copper strip and a very good optical access. For the optical observation of the bubble behaviour the high-speed cinematography is used. Automated image processing and analysis algorithms developed by the authors were applied for a wide range of mass flow rates and heat fluxes in order to extract characteristic length and time scales of the bubbly layer during the boiling process. Using this methodology, a huge number of bubble cycles could be analysed. The structure of the developed algorithms for the detection of the bubble diameter, the bubble lifetime, the lifetime after the detachment process and the waiting time between two bubble cycles is described. Subsequently, the results from using these automated procedures are presented. A remarkable novelty is the presentation of all results as distribution functions. This is of physical importance because the commonly applied spatial and temporal averaging leads to a loss of information and, moreover, to an unjustified deterministic view of the boiling process, which exhibits in reality a very wide spread of bubble sizes and characteristic times. The results show that the mass flux dominates the temporal bubble behaviour. An increase of the liquid mass flux reveals a strong decrease of the bubble life- and waiting time. In contrast, the variation of the heat flux has a much smaller impact. It is shown in addition that the investigation of the bubble history using automated algorithms delivers novel information with respect to the bubble lift-off probability

  14. Bubble Size Distribution in a Vibrating Bubble Column

    Science.gov (United States)

    Mohagheghian, Shahrouz; Wilson, Trevor; Valenzuela, Bret; Hinds, Tyler; Moseni, Kevin; Elbing, Brian

    2016-11-01

    While vibrating bubble columns have increased the mass transfer between phases, a universal scaling law remains elusive. Attempts to predict mass transfer rates in large industrial scale applications by extrapolating laboratory scale models have failed. In a stationary bubble column, mass transfer is a function of phase interfacial area (PIA), while PIA is determined based on the bubble size distribution (BSD). On the other hand, BSD is influenced by the injection characteristics and liquid phase dynamics and properties. Vibration modifies the BSD by impacting the gas and gas-liquid dynamics. This work uses a vibrating cylindrical bubble column to investigate the effect of gas injection and vibration characteristics on the BSD. The bubble column has a 10 cm diameter and was filled with water to a depth of 90 cm above the tip of the orifice tube injector. BSD was measured using high-speed imaging to determine the projected area of individual bubbles, which the nominal bubble diameter was then calculated assuming spherical bubbles. The BSD dependence on the distance from the injector, injector design (1.6 and 0.8 mm ID), air flow rates (0.5 to 5 lit/min), and vibration conditions (stationary and vibration conditions varying amplitude and frequency) will be presented. In addition to mean data, higher order statistics will also be provided.

  15. A model established of a 'Embryo' bubble growing-up some visible bubble in bubble chamber and its primary theory calculation

    International Nuclear Information System (INIS)

    Ye Zipiao; Sheng Xiangdong

    2006-01-01

    A model of a 'embryo' bubble growing up a visible bubble in the bubble chamber is established. Through primary theory calculation it is shown that the 'embryo' bubble is not only absorbing quantity of heat, but also some molecules get into the 'embryo' bubble from its environment. It is explained reasonably that the radius of bubbles in bubble camber is different for the same energies of neutrons and proton. The track of neutron in bubble camber is long and thin, and the track of proton in bubble camber is wide and short. It is explained reasonably that the bubble radius of the incident particles with more charges which there are the same energies will be wider than that of the incident particles with less charges in the track. It is also explained reasonably that there are a little different radius of the bubbles of a track at the some region. It can be predicted theoretically that there should be big bubbles to burst when incident particles enter the bubble chamber at first. The sensitivity and the detective efficiency of bubble camber can be enhanced by choosing appropriate work matter. (authors)

  16. Circulating procoagulant microparticles in cancer patients

    OpenAIRE

    Thaler, Johannes; Ay, Cihan; Weinstabl, Harald; Dunkler, Daniela; Simanek, Ralph; Vormittag, Rainer; Freyssinet, Jean-Marie; Zielinski, Christoph; Pabinger, Ingrid

    2010-01-01

    Abstract Accumulating evidence indicates that microparticles (MPs) are important mediators of the interaction between cancer and the hemostatic system. We conducted a large prospective cohort study to determine whether the number of circulating procoagulant MPs is elevated in cancer patients and whether the elevated MP levels are predictive of occurrence of venous thrombembolism (VTE). We analyzed plasma samples of 728 cancer patients from the ongoing prospective observational Vien...

  17. The Behavior of Micro Bubbles and Bubble Cluster in Ultrasound Field

    Science.gov (United States)

    Yoshizawa, Shin; Matsumoto, Yoichiro

    2001-11-01

    Ultrasound is widely applied in the clinical field today, such as ultrasound imaging, Extracorporeal Shock Wave Lithotripsy (ESWL) and so on. It is essential to take a real understanding of the dynamics of micro bubbles and bubble cluster in these applications. Thus we numerically simulate them in ultrasound field in this paper. In the numerical simulation, we consider the thermal behavior inside the bubble and the pressure wave phenomena in the bubble cluster in detail, namely, the evaporation and condensation of liquid at the bubble wall, heat transfer through the bubble wall, diffusion of non-condensable gas inside the bubble and the compressibility of liquid. Initial cluster radius is to 0.5[mm], bubble radius is 1.7[mm], void fraction is 0.1[ambient pressure is 101.3[kPa], temperature is 293[K] and the amplitude of ultrasound is 50[kPa]. We simulate bubble cluster in ultrasound field at various frequencies and we obtain the following conclusions. 1) The maximum pressure inside bubble cluster reaches 5[MPa] and this is much higher than that of a bubble. 2) Bubble cluster behaves like a rigid body acoustically when the frequency of ultrasound is much higher than its natural frequency.

  18. Hydrogen extraction from liquid lithium-lead alloy by bubbling with rotational jet nozzle

    International Nuclear Information System (INIS)

    Xie Bo; Yang Tongzai; Guan Rui; Weng Kuiping

    2010-01-01

    The technology of tritium extraction from lithium-lead alloy has been simulated, hydrogen extraction from lithium-lead alloy by bubbling with rotational jet nozzle being used to simulate tritium in the study based on the introduction of fluid dynamics to establish algebraic model. The results show that the higher than lithium-lead melting temperature, the higher cumulative hydrogen extraction efficiency, and gas holdup of bubble column is little affected by the impeller diameter. Gas holdup when using small aperture is slightly higher when using large aperture only at a high helium flow rate, but the smaller the aperture, the greater the bubble surface area, and a marked increase in intensity of flow circulation for liquid lithium-lead with the increase of helium flow rate, hydrogen extraction rate increases too. Moreover, influence of the jet rotational velocity on hydrogen extraction is limited. (authors)

  19. A Carbon Dioxide Bubble-Induced Vortex Triggers Co-Assembly of Nanotubes with Controlled Chirality.

    Science.gov (United States)

    Zhang, Ling; Zhou, Laicheng; Xu, Na; Ouyang, Zhenjie

    2017-07-03

    It is challenging to prepare co-organized nanotube systems with controlled nanoscale chirality in an aqueous liquid flow field. Such systems are responsive to a bubbled external gas. A liquid vortex induced by bubbling carbon dioxide (CO 2 ) gas was used to stimulate the formation of nanotubes with controlled chirality; two kinds of achiral cationic building blocks were co-assembled in aqueous solution. CO 2 -triggered nanotube formation occurs by formation of metastable intermediate structures (short helical ribbons and short tubules) and by transition from short tubules to long tubules in response to chirality matching self-assembly. Interestingly, the chirality sign of these assemblies can be selected for by the circulation direction of the CO 2 bubble-induced vortex during the co-assembly process. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Fama on Bubbles

    DEFF Research Database (Denmark)

    Engsted, Tom

    2016-01-01

    While Eugene Fama has repeatedly expressed his discontent with the notion of an “irrational bubble,” he has never publicly expressed his opinion on “rational bubbles.” On empirical grounds Fama rejects bubbles by referring to the lack of reliable evidence that price declines are predictable....... However, this argument cannot be used to rule out rational bubbles because such bubbles do not necessarily imply return predictability, and return predictability of the kind documented by Fama does not rule out rational bubbles. On data samples that include the 1990s, there is evidence of an explosive...... component in stock market valuation ratios, consistent with a rational bubble....

  1. Interaction of a bubble and a bubble cluster in an ultrasonic field

    International Nuclear Information System (INIS)

    Wang Cheng-Hui; Cheng Jian-Chun

    2013-01-01

    Using an appropriate approximation, we have formulated the interacting equation of multi-bubble motion for a system of a single bubble and a spherical bubble cluster. The behavior of the bubbles is observed in coupled and uncoupled states. The oscillation of bubbles inside the cluster is in a coupled state. The numerical simulation demonstrates that the secondary Bjerknes force can be influenced by the number density, initial radius, distance, driving frequency, and amplitude of ultrasound. However, if a bubble approaches a bubble cluster of the same initial radii, coupled oscillation would be induced and a repulsive force is evoked, which may be the reason why the bubble cluster can exist steadily. With the increment of the number density of the bubble cluster, a secondary Bjerknes force acting on the bubbles inside the cluster decreases due to the strong suppression of the coupled bubbles. It is shown that there may be an optimal number density for a bubble cluster which can generate an optimal cavitation effect in liquid for a stable driving ultrasound. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  2. CT-Venography for the diagnosis of deep venous thrombosis of the lower extremities

    Energy Technology Data Exchange (ETDEWEB)

    Matsuhashi, Toshio [Iwaki Kyoritsu Hospital, Fukushima (Japan); Ishii, Kiyoshi; Tsuboi, Masahiro; Saito, Haruo; Ishibashi, Tadashi; Takahashi, Shoki

    2000-12-01

    We evaluated imaging of deep venous thrombosis (DVT) of the lower extremities using CT-Venography. CT-Venography was performed in 11 patients with suspected DVT. This method clearly demonstrated thrombus extension of DVT and collateral circulation. We concluded that CT-Venography was useful in the evaluation of DVT of the lower extremities. (author)

  3. Bubble systems

    CERN Document Server

    Avdeev, Alexander A

    2016-01-01

    This monograph presents a systematic analysis of bubble system mathematics, using the mechanics of two-phase systems in non-equilibrium as the scope of analysis. The author introduces the thermodynamic foundations of bubble systems, ranging from the fundamental starting points to current research challenges. This book addresses a range of topics, including description methods of multi-phase systems, boundary and initial conditions as well as coupling requirements at the phase boundary. Moreover, it presents a detailed study of the basic problems of bubble dynamics in a liquid mass: growth (dynamically and thermally controlled), collapse, bubble pulsations, bubble rise and breakup. Special emphasis is placed on bubble dynamics in turbulent flows. The analysis results are used to write integral equations governing the rate of vapor generation (condensation) in non-equilibrium flows, thus creating a basis for solving a number of practical problems. This book is the first to present a comprehensive theory of boil...

  4. Treatment of micro air bubbles in rat adipose tissue at 25 kPa altitude exposures with perfluorocarbon emulsions and nitric oxide.

    Science.gov (United States)

    Randsøe, Thomas; Hyldegaard, O

    2014-01-01

    Perfluorocarbon emulsions (PFC) and nitric oxide (NO) releasing agents have on experimental basis demonstrated therapeutic properties in treating and preventing the formation of venous gas embolism as well as increased survival rate during decompression sickness from diving. The effect is ascribed to an increased solubility and transport capacity of respiratory gases in the PFC emulsion and possibly enhanced nitrogen washout through NO-increased blood flow rate and/or the removal of endothelial micro bubble nuclei precursors. Previous reports have shown that metabolic gases (i.e., oxygen in particular) and water vapor contribute to bubble growth and stabilization during altitude exposures. Accordingly, we hypothesize that the administration of PFC and NO donors upon hypobaric pressure exposures either (1) enhance the bubble disappearance rate through faster desaturation of nitrogen, or in contrast (2) promote bubble growth and stabilization through an increased oxygen supply. In anesthetized rats, micro air bubbles (containing 79% nitrogen) of 4-500 nl were injected into exposed abdominal adipose tissue. Rats were decompressed in 36 min to 25 kPa (~10,376 m above sea level) and bubbles studied for 210 min during continued oxygen breathing (FIO2 = 1). Rats were administered PFC, NO, or combined PFC and NO. In all groups, most bubbles grew transiently, followed by a stabilization phase. There were no differences in the overall bubble growth or decay between groups or when compared with previous data during oxygen breathing alone at 25 kPa. During extreme altitude exposures, the contribution of metabolic gases to bubble growth compromises the therapeutic effects of PFC and NO, but PFC and NO do not induce additional bubble growth.

  5. The causes of skin damage and leg ulceration in chronic venous disease.

    Science.gov (United States)

    Smith, Philip Coleridge

    2006-09-01

    Chronic venous disease with skin changes of the leg is a common condition affecting up to 1 in 20 people in westernized countries. The causes of this problem are not fully understood, although research in recent years has revealed a number of important mechanisms that contribute to the disease process. Patients with chronic venous disease suffer persistently raised pressures in their deep and superficial veins in the lower limb. Leucocytes become "trapped" in the circulation of the leg during periods of venous hyper-tension produced by sitting or standing. Studies of the plasma levels of neutrophil granule enzymes shows that these are increased during periods of venous hypertension, suggesting that this causes activation of the neutrophils. Investigation of the leucocyte surface ligands CD11b and CD62L shows that the more activated neutrophils and monocytes are sequestered during venous hypertension. Measurement of plasma levels of the soluble parts of the endothelial adhesion molecules VCAM, ICAM, and ELAM show that these are all elevated in patients with chronic venous disease compared to controls. Following 30 minutes of venous hypertension produced by standing, these levels are further increased. These data suggest that venous hypertension causes neutrophil and monocyte activation, which in turn causes injury to the endothelium. Chronic injury to the endothelium leads to a chronic inflammatory condition of the skin that we know clinically as lipodermatosclerosis. This is mediated by perivascular inflammatory cells, principally macrophages, in the skin microcirculation. These stimulate fibroblasts in the skin leading to tissue remodeling and laying down of fibrous tissue. Vascular endothelial growth factor stimulates proliferation of capillaries within the skin. Skin in this state has the potential to ulcerate in response to minor injury.

  6. How are soap bubbles blown? Fluid dynamics of soap bubble blowing

    Science.gov (United States)

    Davidson, John; Lambert, Lori; Sherman, Erica; Wei, Timothy; Ryu, Sangjin

    2013-11-01

    Soap bubbles are a common interfacial fluid dynamics phenomenon having a long history of delighting not only children and artists but also scientists. In contrast to the dynamics of liquid droplets in gas and gas bubbles in liquid, the dynamics of soap bubbles has not been well documented. This is possibly because studying soap bubbles is more challenging due to there existing two gas-liquid interfaces. Having the thin-film interface seems to alter the characteristics of the bubble/drop creation process since the interface has limiting factors such as thickness. Thus, the main objective of this study is to determine how the thin-film interface differentiates soap bubbles from gas bubbles and liquid drops. To investigate the creation process of soap bubbles, we constructed an experimental model consisting of air jet flow and a soap film, which consistently replicates the conditions that a human produces when blowing soap bubbles, and examined the interaction between the jet and the soap film using the high-speed videography and the particle image velocimetry.

  7. Sticky bubbles

    NARCIS (Netherlands)

    Antoniuk, O.; Bos, van der A.; Driessen, T.W.; Es, van B.; Jeurissen, R.J.M.; Michler, D.; Reinten, H.; Schenker, M.; Snoeijer, J.H.; Srivastava, S.; Toschi, F.; Wijshoff, H.M.A.

    2011-01-01

    We discuss the physical forces that are required to remove an air bubble immersed in a liquid from a corner. This is relevant for inkjet printing technology, as the presence of air bubbles in the channels of a printhead perturbs the jetting of droplets. A simple strategy to remove the bubble is to

  8. Reconstruction of circulation in the fingertip without vein repair in zone I replantation.

    Science.gov (United States)

    Zhang, Xu; Wen, Sumin; Wang, Baoshi; Wang, Qi; Li, Chenglin; Zhu, Hongwei

    2008-11-01

    In fingertip replantation, adequate venous drainage is important for success. As the level of amputation becomes more distal, anastomosis of veins becomes more technically difficult. External bleeding is a common solution to venous congestion, but the process is burdensome because of duration of bleeding for 3 or more days after surgery. We present a new technique for reconstructing circulation without vein anastomosis in zone I replantation and analyze the outcomes of this technique in terms of eliminating external bleeding and of a high survival rate of the replanted digits. Between 1997 and 2007, we performed 120 replantations in 112 patients (83 male and 29 female; mean age, 33 years; range, 3-54 years). All were zone I amputations, based on the Tamai classification. We surgically repaired both proper digital arteries, excluded the vein, and then ligated 1 of the arteries. Using this technique, circulation was restored. Included in the outcome evaluation were 91 digits in the 87 patients (mean age, 35 years; range, 14-54) who returned for outcome assessments 12 months after surgery. Of 120 digits replanted, 115 digits survived, corresponding to an overall success rate of 96%. No patients received alternative means to alleviate venous congestion, such as leeches or other means of external bleeding. Nearly all of the 87 patients (91 digits) were satisfied with the results of the replantations. Our technique reconstructs circulation without vein anastomosis in zone I replantation. This alternative to venous congestion involves a simple surgical procedure and straightforward postoperative care. Follow-up assessments of a series of 120 replantations show that the majority of zone I replantations led to satisfactory function. We therefore propose this technique as an effective method for zone I replantation. Therapeutic IV.

  9. Formation and evolution of bubbly screens in confined oscillating bubbly liquids

    Science.gov (United States)

    Shklyaev, Sergey; Straube, Arthur V.

    2010-01-01

    We consider the dynamics of dilute monodisperse bubbly liquid confined by two plane solid walls and subject to small-amplitude high-frequency oscillations normal to the walls. The initial state corresponds to the uniform distribution of bubbles and motionless liquid. The period of external driving is assumed much smaller than typical relaxation times for a single bubble but larger than the period of volume eigenoscillations. The time-averaged description accounting for the two-way coupling between the liquid and the bubbles is applied. We show that the model predicts accumulation of bubbles in thin sheets parallel to the walls. These singular structures, which are formally characterized by infinitely thin width and infinitely high concentration, are referred to as bubbly screens. The formation of a bubbly screen is described analytically in terms of a self-similar solution, which is in agreement with numerical simulations. We study the evolution of bubbly screens and detect a one-dimensional stationary state, which is shown to be unconditionally unstable.

  10. Characterization of Bubble Size Distributions within a Bubble Column

    OpenAIRE

    Shahrouz Mohagheghian; Brian R. Elbing

    2018-01-01

    The current study experimentally examines bubble size distribution (BSD) within a bubble column and the associated characteristic length scales. Air was injected into a column of water via a single injection tube. The column diameter (63–102 mm), injection tube diameter (0.8–1.6 mm) and superficial gas velocity (1.4–55 mm/s) were varied. Large samples (up to 54,000 bubbles) of bubble sizes measured via 2D imaging were used to produce probability density functions (PDFs). The PDFs were used to...

  11. Rational equity bubbles

    OpenAIRE

    Zhou, Ge

    2012-01-01

    This paper discusses the existence of a bubble in the pricing of an asset that pays positive dividends. I show that rational bubbles can exist in a growing economy. The existence of bubbles depends on the relative magnitudes of risk aversion to consumption and to wealth. Furthermore, I examine how an exogenous shock in technology might trigger bubbles.

  12. Venous hemodynamic changes in lower limb venous disease

    DEFF Research Database (Denmark)

    Lee, Byung Boong; Nicolaides, Andrew N; Myers, Kenneth

    2016-01-01

    ). Their aim was to confirm or dispel long-held hemodynamic principles and to provide a comprehensive review of venous hemodynamic concepts underlying the pathophysiology of lower limb venous disorders, their usefulness for investigating patients and the relevant hemodynamic changes associated with various...... forms of treatment. Chapter 1 is devoted to basic hemodynamic concepts and normal venous physiology. Chapter 2 presents the mechanism and magnitude of hemodynamic changes in acute deep vein thrombosis indicating their pathophysiological and clinical significance. Chapter 3 describes the hemodynamic...... changes that occur in different classes of chronic venous disease and their relation to the anatomic extent of disease in the macrocirculation and microcirculation. The next four chapters (Chapters 4-7) describe the hemodynamic changes resulting from treatment by compression using different materials...

  13. Sequential Blood Filtration for Extracorporeal Circulation: Initial Results from a Proof-of-Concept Prototype

    Science.gov (United States)

    Herbst, Daniel P.

    2014-01-01

    Abstract: Micropore filters are used during extracorporeal circulation to prevent gaseous and solid particles from entering the patient’s systemic circulation. Although these devices improve patient safety, limitations in current designs have prompted the development of a new concept in micropore filtration. A prototype of the new design was made using 40-μm filter screens and compared against four commercially available filters for performance in pressure loss and gross air handling. Pre- and postfilter bubble counts for 5- and 10-mL bolus injections in an ex vivo test circuit were recorded using a Doppler ultrasound bubble counter. Statistical analysis of results for bubble volume reduction between test filters was performed with one-way repeated-measures analysis of variance using Bonferroni post hoc tests. Changes in filter performance with changes in microbubble load were also assessed with dependent t tests using the 5- and 10-mL bolus injections as the paired sample for each filter. Significance was set at p < .05. All filters in the test group were comparable in pressure loss performance, showing a range of 26–33 mmHg at a flow rate of 6 L/min. In gross air-handling studies, the prototype showed improved bubble volume reduction, reaching statistical significance with three of the four commercial filters. All test filters showed decreased performance in bubble volume reduction when the microbubble load was increased. Findings from this research support the underpinning theories of a sequential arterial-line filter design and suggest that improvements in microbubble filtration may be possible using this technique. PMID:26357790

  14. Chaotic bubbling and nonstagnant foams.

    Science.gov (United States)

    Tufaile, Alberto; Sartorelli, José Carlos; Jeandet, Philippe; Liger-Belair, Gerard

    2007-06-01

    We present an experimental investigation of the agglomeration of bubbles obtained from a nozzle working in different bubbling regimes. This experiment consists of a continuous production of bubbles from a nozzle at the bottom of a liquid column, and these bubbles create a two-dimensional (2D) foam (or a bubble raft) at the top of this column. The bubbles can assemble in various dynamically stable arrangement, forming different kinds of foams in a liquid mixture of water and glycerol, with the effect that the bubble formation regimes influence the foam obtained from this agglomeration of bubbles. The average number of bubbles in the foam is related to the bubble formation frequency and the bubble mean lifetime. The periodic bubbling can generate regular or irregular foam, while a chaotic bubbling only generates irregular foam.

  15. Experimental study of steam bubble velocities and dimensions in the draught trunk of the AST-500 reactor simulator

    International Nuclear Information System (INIS)

    Shanin, V.K.; Drobkov, V.P.; Kulakov, I.V.; Khalmeh, M.V.

    1988-01-01

    Local characteristics for two-phase steam water flow in the vertical channel with 0.45 m diameter and 2 m length, which is the draught trunk of the AST-500 reactor simulator, are investigated. Steam bubble velocities and dimensions were determined by the time-of-flight method using the twinned conductometric transducers. The data obtained testify to the existance of unstable circulation flows in the trunk peripheral region. These flows effect considerably the steam phase motion in the trunk middle part. At the same time the circulation flows to a lesser degree affect steam bubble motion in the trunk low peripheral part and to the lesser degree affect the steam phase in the axial zone near the outlet from the heating section. So the data obtained confirm the conclusion, made earlier, about steam-water flow acceleration in the draught trunk central part

  16. Study on bubble column humidification and dehumidification system for coal mine wastewater treatment.

    Science.gov (United States)

    Gao, Penghui; Zhang, Meng; Du, Yuji; Cheng, Bo; Zhang, Donghai

    2018-04-01

    Water is important resource for human survival and development. Coal mine wastewater (CMW) is a byproduct of the process of coal mining, which is about 7.0 × 10 10 m 3 in China in 2016. Considering coal mine wastewater includes different ingredients, a new bubble column humidification and dehumidification system is proposed for CMW treatment. The system is mainly composed of a bubble column humidification and dehumidification unit, solar collector, fan and water tank, in which air is used as a circulating medium. The system can avoid water treatment component blocking for reverse osmosis (RO) and multi effect distillation (MED) dealing with CMW, and produce water greenly. By analysis of heat and mass transfer, the effects of solar radiation, air bubble velocity and mine water temperature on water treatment production characteristics are studied. Compared with other methods, thermal energy consumption (TEC) of bubble column humidification and dehumidification (BCHD) is moderate, which is about 700 kJ/kg (powered by solar energy). The results would provide a new method for CMW treatment and insights into the efficient coal wastewater treatment, besides, it helps to identify the parameters for the technology development in mine water treatment.

  17. Bubble levitation and translation under single-bubble sonoluminescence conditions.

    Science.gov (United States)

    Matula, Thomas J

    2003-08-01

    Bubble levitation in an acoustic standing wave is re-examined for conditions relevant to single-bubble sonoluminescence. Unlike a previous examination [Matula et al., J. Acoust. Soc. Am. 102, 1522-1527 (1997)], the stable parameter space [Pa,R0] is accounted for in this realization. Forces such as the added mass force and drag are included, and the results are compared with a simple force balance that equates the Bjerknes force to the buoyancy force. Under normal sonoluminescence conditions, the comparison is quite favorable. A more complete accounting of the forces shows that a stably levitated bubble does undergo periodic translational motion. The asymmetries associated with translational motion are hypothesized to generate instabilities in the spherical shape of the bubble. A reduction in gravity results in reduced translational motion. It is hypothesized that such conditions may lead to increased light output from sonoluminescing bubbles.

  18. Cavitation bubble nucleation induced by shock-bubble interaction in a gelatin gel

    Science.gov (United States)

    Oguri, Ryota; Ando, Keita

    2018-05-01

    An optical visualization technique is developed to study cavitation bubble nucleation that results from interaction between a laser-induced shock and a preexisting gas bubble in a 10 wt. % gelatin gel; images of the nucleated cavitation bubbles are captured and the cavitation inception pressure is determined based on Euler flow simulation. A spherical gas cavity is generated by focusing an infrared laser pulse into a gas-supersaturated gel and the size of the laser-generated bubble in mechanical equilibrium is tuned via mass transfer of the dissolved gas into the bubble. A spherical shock is then generated, through rapid expansion of plasma induced by the laser focusing, in the vicinity of the gas bubble. The shock-bubble interaction is recorded by a CCD camera with flash illumination of a nanosecond green laser pulse. The observation captures cavitation inception in the gel under tension that results from acoustic impedance mismatching at the bubble interface interacting with the shock. We measure the probability of cavitation inception from a series of the repeated experiments, by varying the bubble radius and the standoff distance. The threshold pressure is defined at the cavitation inception probability equal to one half and is calculated, through comparisons to Euler flow simulation, at -24.4 MPa. This threshold value is similar to that from shock-bubble interaction experiments using water, meaning that viscoelasticity of the 10 wt. % gelatin gel has a limited impact on bubble nucleation dynamics.

  19. Transesophageal Echocardiographically-Confirmed Pulmonary Vein Thrombosis in Association with Posterior Circulation Infarction.

    LENUS (Irish Health Repository)

    Kinsella, Justin A

    2010-01-01

    Pulmonary venous thromboembolism has only been identified as a cause of stroke with pulmonary arteriovenous malformations\\/fistulae, pulmonary neoplasia, transplantation or lobectomy, and following percutaneous radiofrequency ablation of pulmonary vein ostia in patients with atrial fibrillation. A 59-year-old man presented with a posterior circulation ischemic stroke. \\'Unheralded\\' pulmonary vein thrombosis was identified on transesophageal echocardiography as the likely etiology. He had no further cerebrovascular events after intensifying antithrombotic therapy. Twenty-eight months after initial presentation, he was diagnosed with metastatic pancreatic adenocarcinoma and died 3 months later. This report illustrates the importance of doing transesophageal echocardiography in presumed \\'cardioembolic\\' stroke, and that potential \\'pulmonary venous thromboembolic\\' stroke may occur in patients without traditional risk factors for venous thromboembolism. Consideration should be given to screening such patients for occult malignancy.

  20. Body fat does not affect venous bubble formation after air dives of moderate severity: theory and experiment

    NARCIS (Netherlands)

    Schellart, Nico A. M.; van Rees Vellinga, Tjeerd P.; van Hulst, Rob A.

    2013-01-01

    For over a century, studies on body fat (BF) in decompression sickness and venous gas embolism of divers have been inconsistent. A major problem is that age, BF, and maximal oxygen consumption (Vo2max) show high multicollinearity. Using the Bühlmann model with eight parallel compartments, preceded

  1. Direct venous thrombolysis and venous angioplasty in the upper extremity

    International Nuclear Information System (INIS)

    Hollmann, J.P.; Guenther, R.W.

    1987-01-01

    Venous thromboses of stenoses in the upper extremity are often the result of a compression syndrome of the shoulder girdle, the Paget-von Schroetter syndrome, vascular surgery, space-occupying lesions in the mediastinum or the result of catheterisation. Direct venous thrombolysis and venous angioplasty were performed successfully in six patients. (orig.) [de

  2. Analysis of the vertebral venous system in relation to cerebral venous drainage on MR angiography

    International Nuclear Information System (INIS)

    Baik, Seung Kug; Sohn, Chul Ho; Kim, Gab Chul; Kim, Yong Sun

    2004-01-01

    In the supine position, cerebral venous drainage occurs primarily through the internal jugular veins, as seen on venous phase cerebral angiography. However, in the erect position, the vertebral venous system represents the major alternative pathway of cerebral venous drainage, while outflow through the internal jugular veins is absent or negligible. The purpose of this study is to evaluate the vertebral venous system and its relationship between the surrounding venous structures using magnetic resonance angiography (MRA) in the case of subjects in the supine position. We retrospectively reviewed the results of 65 patients (M:F = 31: 34, mean age 61.6 years) who underwent multi-phase contrast-enhanced carotid MRA. The imaging studies were performed using a 3.0 T MR unit (TR: 5.2, TE: 1.1, FA: 20, 3.8 thickness, EC: 1). We analyzed the appearance and extent of the vertebral venous system (vertebral venous plexus and vertebral artery venous plexus) and the internal jugular vein on the venous phase images. We also evaluated the main drainage pattern of the cerebral venous drainage and the drainage pattern of the vertebral venous system. The visualized vertebral venous system was defined as either poor, vertebral venous plexus dominant, vertebral artery venous plexus dominant or mixed. In the vertebral venous system, the vertebral artery venous plexus was visualized in 54 cases (83%). The appearance of the visualized vertebral artery venous plexus was symmetrical in 39 cases (72%) and asymmetrical in 15 cases (28%). The extent of the visualized vertebral artery venous plexus was partial in 26 cases (48%) and complete in 28 cases (52%). The vertebral venous plexus was visualized in 62 cases (95%). The appearance of the visualized vertebral artery venous plexus was symmetrical in 43 cases (69%) and asymmetrical in 19 cases (31%). The extent of the visualized vertebral artery venous plexus was partial in 35 cases (56%) and complete in 27 cases (44%). The appearance of the

  3. Bubbling away

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1993-10-15

    Bubble chambers may have almost vanished from the front line of physics research, but the vivid memory of their intricate and sometimes beautiful patterns of particle tracks lives on, and has greatly influenced the computer graphics of track reconstruction in today's big experiments. 'Seeing' an interaction makes it more understandable. Bubble chambers, with their big collaborations of physicists from many widely scattered research institutes, started another ball rolling. The groups formed are even now only surpassed in size by the big collaborations working on today's major detectors at colliding beam machines. From 14-16 July, about 130 physicists gathered at CERN to commemorate the 40th anniversary of the invention of the bubble chamber by Donald Glaser. The meeting, organized by Derek C. Colley from Birmingham, gave a comprehensive overview of bubble chamber contributions to physics, their challenging technology, and the usefulness of bubble chamber photographs in education, both for physics and the public at large. After opening remarks by CERN Director Carlo Rubbia, Donald Glaser began with a brief review of the work which led to his invention - there was much more to it than idly watching beer bubbles rise up the wall of the glass - before turning to his present line of research, biophysics, also very visually oriented.

  4. Effect of bubble interface parameters on predicted of bubble departure diameter in a narrow channel

    International Nuclear Information System (INIS)

    Xu Jianjun; Xie Tianzhou; Zhou Wenbin; Chen Bingde; Huang Yanping

    2014-01-01

    The predicted model on the bubble departure diameter in a narrow channel is built by analysis of forces acting on the bubble, and effects of bubble interface parameters such as the bubble inclination angle, upstream contact angle, downstream contact angle and bubble contact diameter on predicted bubble departure diameters in a narrow channel are analysed by comparing with the visual experimental data. Based on the above results, the bubble interface parameters as the input parameters used to obtain the bubble departure diameter in a narrow channel are assured, and the bubble departure diameters in a narrow channel are predicted by solving the force equation. The predicted bubble departure diameters are verified by the 58 bubble departure diameters obtained from the vertical and inclined visual experiment, and the predicted results agree with the experimental results. The different forces acting on the bubble are obtained and the effect of thermal parameters in this experiment on bubble departure diameters is analysed. (authors)

  5. Bubble Collision in Curved Spacetime

    International Nuclear Information System (INIS)

    Hwang, Dong-il; Lee, Bum-Hoon; Lee, Wonwoo; Yeom, Dong-han

    2014-01-01

    We study vacuum bubble collisions in curved spacetime, in which vacuum bubbles were nucleated in the initial metastable vacuum state by quantum tunneling. The bubbles materialize randomly at different times and then start to grow. It is known that the percolation by true vacuum bubbles is not possible due to the exponential expansion of the space among the bubbles. In this paper, we consider two bubbles of the same size with a preferred axis and assume that two bubbles form very near each other to collide. The two bubbles have the same field value. When the bubbles collide, the collided region oscillates back-and-forth and then the collided region eventually decays and disappears. We discuss radiation and gravitational wave resulting from the collision of two bubbles

  6. Interfacial Bubble Deformations

    Science.gov (United States)

    Seymour, Brian; Shabane, Parvis; Cypull, Olivia; Cheng, Shengfeng; Feitosa, Klebert

    Soap bubbles floating at an air-water experience deformations as a result of surface tension and hydrostatic forces. In this experiment, we investigate the nature of such deformations by taking cross-sectional images of bubbles of different volumes. The results show that as their volume increases, bubbles transition from spherical to hemispherical shape. The deformation of the interface also changes with bubble volume with the capillary rise converging to the capillary length as volume increases. The profile of the top and bottom of the bubble and the capillary rise are completely determined by the volume and pressure differences. James Madison University Department of Physics and Astronomy, 4VA Consortium, Research Corporation for Advancement of Science.

  7. Characterization of Bubble Size Distributions within a Bubble Column

    Directory of Open Access Journals (Sweden)

    Shahrouz Mohagheghian

    2018-02-01

    Full Text Available The current study experimentally examines bubble size distribution (BSD within a bubble column and the associated characteristic length scales. Air was injected into a column of water via a single injection tube. The column diameter (63–102 mm, injection tube diameter (0.8–1.6 mm and superficial gas velocity (1.4–55 mm/s were varied. Large samples (up to 54,000 bubbles of bubble sizes measured via 2D imaging were used to produce probability density functions (PDFs. The PDFs were used to identify an alternative length scale termed the most frequent bubble size (dmf and defined as the peak in the PDF. This length scale as well as the traditional Sauter mean diameter were used to assess the sensitivity of the BSD to gas injection rate, injector tube diameter, injection tube angle and column diameter. The dmf was relatively insensitive to most variation, which indicates these bubbles are produced by the turbulent wakes. In addition, the current work examines higher order statistics (standard deviation, skewness and kurtosis and notes that there is evidence in support of using these statistics to quantify the influence of specific parameters on the flow-field as well as a potential indicator of regime transitions.

  8. Fama on bubbles

    DEFF Research Database (Denmark)

    Engsted, Tom

    Eugene Fama has repeatedly expressed his discontent with the notion of an irrational bubble. However, he has never publicly expressed his opinion on rational bubbles. This is peculiar since such bubbles build naturally from the rational efficient markets paradigm that Fama strongly adheres to...

  9. Bubbling away

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Bubble chambers may have almost vanished from the front line of physics research, but the vivid memory of their intricate and sometimes beautiful patterns of particle tracks lives on, and has greatly influenced the computer graphics of track reconstruction in today's big experiments. 'Seeing' an interaction makes it more understandable. Bubble chambers, with their big collaborations of physicists from many widely scattered research institutes, started another ball rolling. The groups formed are even now only surpassed in size by the big collaborations working on today's major detectors at colliding beam machines. From 14-16 July, about 130 physicists gathered at CERN to commemorate the 40th anniversary of the invention of the bubble chamber by Donald Glaser. The meeting, organized by Derek C. Colley from Birmingham, gave a comprehensive overview of bubble chamber contributions to physics, their challenging technology, and the usefulness of bubble chamber photographs in education, both for physics and the public at large. After opening remarks by CERN Director Carlo Rubbia, Donald Glaser began with a brief review of the work which led to his invention - there was much more to it than idly watching beer bubbles rise up the wall of the glass - before turning to his present line of research, biophysics, also very visually oriented

  10. Circulation induced by diffused aeration in a shallow lake | Toné ...

    African Journals Online (AJOL)

    Field surveys were carried out to investigate the surface jet flows and the resulting circulation patterns generated by diffused aeration in a shallow lake. In conrast to previous studies, the experimental conditions included point-source bubble plumes with very high air flow rates (100–400 L/min) relative to the shallow water ...

  11. Magnetic-bubble devices

    International Nuclear Information System (INIS)

    Fairholme, R.J.

    1978-01-01

    Magnetic bubbles were first described only ten years ago when research workers were discussing orthoferrites containing μm diameter bubbles. However, problems of material fabrication limit crystals to a few mm across which severely curtailed device development. Since then materials have changed and rare-earth-iron garnet films can be grown up 3 inches in diameter with bubble diameters down to sizes below 1 μm. The first commercial products have device capacities in the range 64 000 to 100 000 bits with bubble diameters between 4 and 6 μm. Chip capacities of 1 Mbit are presently under development in the laboratory, as are new techniques to use submicrometre bubbles. The operation and fabrication of a bubble device is described using the serial loop devices currently being manufactured at Plessey as models. Chip organization is one important variable which directly affects the access time. A range of access times and capacities is available which offers a wide range of market opportunities, ranging from consumer products to fixed head disc replacements. some of the application areas are described. (author)

  12. Nonlinear Bubble Dynamics And The Effects On Propagation Through Near-Surface Bubble Layers

    Science.gov (United States)

    Leighton, Timothy G.

    2004-11-01

    Nonlinear bubble dynamics are often viewed as the unfortunate consequence of having to use high acoustic pressure amplitudes when the void fraction in the near-surface oceanic bubble layer is great enough to cause severe attenuation (e.g. >50 dB/m). This is seen as unfortunate since existing models for acoustic propagation in bubbly liquids are based on linear bubble dynamics. However, the development of nonlinear models does more than just allow quantification of the errors associated with the use of linear models. It also offers the possibility of propagation modeling and acoustic inversions which appropriately incorporate the bubble nonlinearity. Furthermore, it allows exploration and quantification of possible nonlinear effects which may be exploited. As a result, high acoustic pressure amplitudes may be desirable even in low void fractions, because they offer opportunities to gain information about the bubble cloud from the nonlinearities, and options to exploit the nonlinearities to enhance communication and sonar in bubbly waters. This paper presents a method for calculating the nonlinear acoustic cross-sections, scatter, attenuations and sound speeds from bubble clouds which may be inhomogeneous. The method allows prediction of the time dependency of these quantities, both because the cloud may vary and because the incident acoustic pulse may have finite and arbitrary time history. The method can be readily adapted for bubbles in other environments (e.g. clouds of interacting bubbles, sediments, structures, in vivo, reverberant conditions etc.). The possible exploitation of bubble acoustics by marine mammals, and for sonar enhancement, is explored.

  13. Prospects for bubble fusion

    Energy Technology Data Exchange (ETDEWEB)

    Nigmatulin, R.I. [Tyumen Institute of Mechanics of Multiphase Systems (TIMMS), Marx (Russian Federation); Lahey, R.T. Jr. [Rensselaer Polytechnic Institute, Troy, NY (United States)

    1995-09-01

    In this paper a new method for the realization of fusion energy is presented. This method is based on the superhigh compression of a gas bubble (deuterium or deuterium/thritium) in heavy water or another liquid. The superhigh compression of a gas bubble in a liquid is achieved through forced non-linear, non-periodic resonance oscillations using moderate amplitudes of forcing pressure. The key feature of this new method is a coordination of the forced liquid pressure change with the change of bubble volume. The corresponding regime of the bubble oscillation has been called {open_quotes}basketball dribbling (BD) regime{close_quotes}. The analytical solution describing this process for spherically symmetric bubble oscillations, neglecting dissipation and compressibility of the liquid, has been obtained. This solution shown no limitation on the supercompression of the bubble and the corresponding maximum temperature. The various dissipation mechanisms, including viscous, conductive and radiation heat losses have been considered. It is shown that in spite of these losses it is possible to achieve very high gas bubble temperatures. This because the time duration of the gas bubble supercompression becomes very short when increasing the intensity of compression, thus limiting the energy losses. Significantly, the calculated maximum gas temperatures have shown that nuclear fusion may be possible. First estimations of the affect of liquid compressibility have been made to determine possible limitations on gas bubble compression. The next step will be to investigate the role of interfacial instability and breaking down of the bubble, shock wave phenomena around and in the bubble and mutual diffusion of the gas and the liquid.

  14. Characteristics of Gas-liquid Mass Transfer and Interfacial Area in a Bubble Column

    International Nuclear Information System (INIS)

    Lim, Dae Ho; Yoo, Dong Jun; Kang, Yong

    2015-01-01

    Characteristics of gas-liquid mass transfer and interfacial area were investigated in a bubble column of diameter and height of 0.102 m and 2.5 m, respectively. Effects of gas and liquid velocities on the volumetric gas-liquid mass transfer coefficient (k L a), interfacial area (a) and liquid side true mass transfer coefficient (k L ) were examined. The interfacial area and volumetric gas-liquid mass transfer coefficient were determined directly by adopting the simultaneous physical desorption of O 2 and chemical absorption of CO 2 in the column. The values of k L a and a increased with increasing gas velocity but decreased with increasing liquid velocity in the bubble column which was operated in the churn turbulent flow regime. The value of k L increased with increasing gas velocity but did not change considerably with increasing liquid velocity. The liquid side mass transfer was found to be related closely to the liquid circulation as well as the effective contacting frequency between the bubbles and liquid phases

  15. Characteristics of Gas-liquid Mass Transfer and Interfacial Area in a Bubble Column

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Dae Ho; Yoo, Dong Jun; Kang, Yong [Chungnam National University, Daejeon (Korea, Republic of)

    2015-02-15

    Characteristics of gas-liquid mass transfer and interfacial area were investigated in a bubble column of diameter and height of 0.102 m and 2.5 m, respectively. Effects of gas and liquid velocities on the volumetric gas-liquid mass transfer coefficient (k{sub L}a), interfacial area (a) and liquid side true mass transfer coefficient (k{sub L}) were examined. The interfacial area and volumetric gas-liquid mass transfer coefficient were determined directly by adopting the simultaneous physical desorption of O{sub 2} and chemical absorption of CO{sub 2} in the column. The values of k{sub L}a and a increased with increasing gas velocity but decreased with increasing liquid velocity in the bubble column which was operated in the churn turbulent flow regime. The value of k{sub L} increased with increasing gas velocity but did not change considerably with increasing liquid velocity. The liquid side mass transfer was found to be related closely to the liquid circulation as well as the effective contacting frequency between the bubbles and liquid phases.

  16. Central venous pressure and mean circulatory filling pressure in the dogfish Squalus acanthias: adrenergic control and role of the pericardium.

    Science.gov (United States)

    Sandblom, Erik; Axelsson, Michael; Farrell, Anthony P

    2006-11-01

    Subambient central venous pressure (Pven) and modulation of venous return through cardiac suction (vis a fronte) characterizes the venous circulation in sharks. Venous capacitance was estimated in the dogfish Squalus acanthias by measuring the mean circulatory filling pressure (MCFP) during transient occlusion of cardiac outflow. We tested the hypothesis that venous return and cardiac preload can be altered additionally through adrenergic changes of venous capacitance. The experiments involved the surgical opening of the pericardium to place a perivascular occluder around the conus arteriosus. Another control group was identically instrumented, but lacked the occluder, and was subjected to the same pharmacological protocol to evaluate how pericardioectomy affected cardiovascular status. Routine Pven was negative (-0.08+/-0.02 kPa) in control fish but positive (0.09+/-0.01 kPa) in the pericardioectomized group. Injections of 5 microg/kg body mass (Mb) of epinephrine and phenylephrine (100 microg/kg Mb) increased Pven and MCFP, whereas isoproterenol (1 microg/kg Mb) decreased both variables. Thus, constriction and relaxation of the venous vasculature were mediated through the respective stimulation of alpha- and beta-adrenergic receptors. Alpha-adrenergic blockade with prazosin (1 mg/kg Mb) attenuated the responses to phenylephrine and decreased resting Pven in pericardioectomized animals. Our results provide convincing evidence for adrenergic control of the venous vasculature in elasmobranchs, although the pericardium is clearly an important component in the modulation of venous function. Thus active changes in venous capacitance have previously been underestimated as an important means of modulating venous return and cardiac performance in this group.

  17. Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

    Energy Technology Data Exchange (ETDEWEB)

    Walser, Eric M., E-mail: walser.eric@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2012-08-15

    The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist of catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.

  18. Bubble parameters analysis of gas-liquid two-phase sparse bubbly flow based on image method

    International Nuclear Information System (INIS)

    Zhou Yunlong; Zhou Hongjuan; Song Lianzhuang; Liu Qian

    2012-01-01

    The sparse rising bubbles of gas-liquid two-phase flow in vertical pipe were measured and studied based on image method. The bubble images were acquired by high-speed video camera systems, the characteristic parameters of bubbles were extracted by using image processing techniques. Then velocity variation of rising bubbles were drawn. Area and centroid variation of single bubble were also drawn. And then parameters and movement law of bubbles were analyzed and studied. The test results showed that parameters of bubbles had been analyzed well by using image method. (authors)

  19. Letter: Entrapment and interaction of an air bubble with an oscillating cavitation bubble

    Science.gov (United States)

    Kannan, Y. S.; Karri, Badarinath; Sahu, Kirti Chandra

    2018-04-01

    The mechanism of the formation of an air bubble due to an oscillating cavitation bubble in its vicinity is reported from an experimental study using high-speed imaging. The cavitation bubble is created close to the free surface of water using a low-voltage spark circuit comprising two copper electrodes in contact with each other. Before the bubble is created, a third copper wire is positioned in contact with the free surface of water close to the two crossing electrodes. Due to the surface tension at the triple point (wire-water-air) interface, a small dip is observed in the free surface at the point where the wire is immersed. When the cavitation bubble is created, the bubble pushes at the dip while expanding and pulls at it while collapsing. The collapse phase leads to the entrapment of an air bubble at the wire immersion point. During this phase, the air bubble undergoes a "catapult" effect, i.e., it expands to a maximum size and then collapses with a microjet at the free surface. To the best of our knowledge, this mechanism has not been reported so far. A parametric study is also conducted to understand the effects of wire orientation and bubble distance from the free surface.

  20. Exercise increases circulating GDF15 in humans

    DEFF Research Database (Denmark)

    Kleinert, Maximilian; Clemmensen, Christoffer; Sjøberg, Kim Anker

    2018-01-01

    OBJECTIVE: The growth differentiation factor 15 (GDF15) is a stress-sensitive circulating factor that regulates systemic energy balance. Since exercise is a transient physiological stress that has pleiotropic effects on whole-body energy metabolism, we herein explored the effect of exercise on a......) circulating GDF15 levels and b) GDF15 release from skeletal muscle in humans. METHODS: Seven healthy males either rested or exercised at 67% of their VO2max for 1 h and blood was sampled from the femoral artery and femoral vein before, during, and after exercise. Plasma GDF15 concentrations were determined...... in these samples. RESULTS: Plasma GDF15 levels increased 34% with exercise (p exercise. There was no difference between the arterial and venous GDF15 concentration before, during, and after exercise. During...

  1. Impact of bubble wakes on a developing bubble flow in a vertical pipe

    International Nuclear Information System (INIS)

    Tomiyama, A.; Makino, Y.; Miyoshi, K.; Tamai, H.; Serizawa, A.; Zun, I.

    1998-01-01

    Three-dimensional two-way bubble tracking simulation of single large air bubbles rising through a stagnant water filled in a vertical pipe was conducted to investigate the structures of bubble wakes. Spatial distributions of time-averaged liquid velocity field, turbulent intensity and Reynolds stress caused by bubble wakes were deduced from the calculated local instantaneous liquid velocities. It was confirmed that wake structures are completely different from the ones estimated by a conventional wake model. Then, we developed a simple wake model based on the predicted time-averaged wake velocity fields, and implemented it into a 3D one-way bubble tracking method to examine the impact of bubble wake structures on time-spatial evolution of a developing air-water bubble flow in a vertical pipe. As a results, we confirmed that the developed wake model can give better prediction for flow pattern evolution than a conventional wake model

  2. A three field two fluid CFD model for the bubbly-cap bubble regime

    International Nuclear Information System (INIS)

    Martin Lopez de Bertodano; Xiaodong Sun; Mamoru Ishii; Asim Ulke

    2005-01-01

    Full text of publication follows: The lateral phase distribution of a two phase duct flow in the cap bubble regime is analyzed with a three dimensional three field two-fluid CFD model based on the turbulent k-ε model for bubbly flows developed by Lopez de Bertodano et. al. [2]. The turbulent diffusion of the bubbles is the dominant phase distribution mechanism. A new analytic result is presented to support the development of the model for the bubble induced turbulent diffusion force. New experimental data obtained with a state-of-the-art four sensor miniature conductivity probe are used to validate the two-fluid model. The focus of this work is modeling the transport of the dispersed phase. Previous work (e.g., Lopez de Bertodano et. al.) was focused on the interfacial forces of drag, lift and virtual mass. However, the dispersion of the bubbles by the turbulent eddies of the continuous phase must be considered too. The rigorous formulation of a model for the turbulent dispersion of the bubbles results in a turbulent diffusion force which is obtained from a probability distribution function average (i.e., Boltzmann averaging) of the dispersed phase momentum equation. This force was recently applied to a turbulent bubbly jet with small bubbles (i.e., 1 mm diameter) without adjusting any coefficient. However, the application of this force to industrial conditions (i.e., larger bubbles) requires specific two-phase flow experimental data to calibrate the model due to the uncertainties of the flow around large bubbles. In particular the void distribution and the interfacial area concentration are measured in a mixture of big and small bubbles. The state-of-the-art miniaturized four-sensor conductivity probe developed by Kim et al. [3] is used to obtain the interfacial area concentration in complex two-phase flow situations. This probe can discriminate between small and large bubbles so it offers an opportunity to perform further developments of the multidimensional two

  3. Bubble bath soap poisoning

    Science.gov (United States)

    ... medlineplus.gov/ency/article/002762.htm Bubble bath soap poisoning To use the sharing features on this page, please enable JavaScript. Bubble bath soap poisoning occurs when someone swallows bubble bath soap. ...

  4. Fatal Cerebral Air Embolism: A Case Series and Literature Review

    Directory of Open Access Journals (Sweden)

    Rashmi Mishra

    2016-01-01

    Full Text Available Cerebral air embolism (CAE is an infrequently reported complication of routine medical procedures. We present two cases of CAE. The first patient was a 55-year-old male presenting with vomiting and loss of consciousness one day after his hemodialysis session. Physical exam was significant for hypotension and hypoxia with no focal neurologic deficits. Computed tomography (CT scan of head showed gas in cerebral venous circulation. The patient did not undergo any procedures prior to presentation, and his last hemodialysis session was uneventful. Retrograde rise of venous air to the cerebral circulation was the likely mechanism for venous CAE. The second patient was a 46-year-old female presenting with fever, shortness of breath, and hematemesis. She was febrile, tachypneic, and tachycardic and required intubation and mechanical ventilation. An orogastric tube inserted drained 2500 mL of bright red blood. Flexible laryngoscopy and esophagogastroduodenoscopy were performed. She also underwent central venous catheter placement. CT scan of head performed the next day due to absent brain stem reflexes revealed intravascular air within cerebral arteries. A transthoracic echocardiogram with bubble study ruled out patent foramen ovale. The patient had a paradoxical CAE in the absence of a patent foramen ovale.

  5. Effect of PEEP, blood volume, and inspiratory hold maneuvers on venous return.

    Science.gov (United States)

    Berger, David; Moller, Per W; Weber, Alberto; Bloch, Andreas; Bloechlinger, Stefan; Haenggi, Matthias; Sondergaard, Soren; Jakob, Stephan M; Magder, Sheldon; Takala, Jukka

    2016-09-01

    According to Guyton's model of circulation, mean systemic filling pressure (MSFP), right atrial pressure (RAP), and resistance to venous return (RVR) determine venous return. MSFP has been estimated from inspiratory hold-induced changes in RAP and blood flow. We studied the effect of positive end-expiratory pressure (PEEP) and blood volume on venous return and MSFP in pigs. MSFP was measured by balloon occlusion of the right atrium (MSFPRAO), and the MSFP obtained via extrapolation of pressure-flow relationships with airway occlusion (MSFPinsp_hold) was extrapolated from RAP/pulmonary artery flow (QPA) relationships during inspiratory holds at PEEP 5 and 10 cmH2O, after bleeding, and in hypervolemia. MSFPRAO increased with PEEP [PEEP 5, 12.9 (SD 2.5) mmHg; PEEP 10, 14.0 (SD 2.6) mmHg, P = 0.002] without change in QPA [2.75 (SD 0.43) vs. 2.56 (SD 0.45) l/min, P = 0.094]. MSFPRAO decreased after bleeding and increased in hypervolemia [10.8 (SD 2.2) and 16.4 (SD 3.0) mmHg, respectively, P waterfall. Copyright © 2016 the American Physiological Society.

  6. Venous Ulcers

    Science.gov (United States)

    Caprini, J.A.; Partsch, H.; Simman, R.

    2013-01-01

    Venous leg ulcers are the most frequent form of wounds seen in patients. This article presents an overview on some practical aspects concerning diagnosis, differential diagnosis and treatment. Duplex ultrasound investigations are essential to ascertain the diagnosis of the underlying venous pathology and to treat venous refluxes. Differential diagnosis includes mainly other vascular lesions (arterial, microcirculatory causes), hematologic and metabolic diseases, trauma, infection, malignancies. Patients with superficial venous incompetence may benefit from endovenous or surgical reflux abolition diagnosed by Duplex ultrasound. The most important basic component of the management is compression therapy, for which we prefer materials with low elasticity applied with high initial pressure (short-stretch bandages and Velcro-strap devices). Local treatment should be simple, absorbing and not sticky dressings keeping adequate moisture balance after debridement of necrotic tissue and biofilms are preferred. After the ulcer is healed compression therapy should be continued in order to prevent recurrence. PMID:26236636

  7. Visualization of airflow growing soap bubbles

    Science.gov (United States)

    Al Rahbi, Hamood; Bock, Matthew; Ryu, Sangjin

    2016-11-01

    Visualizing airflow inside growing soap bubbles can answer questions regarding the fluid dynamics of soap bubble blowing, which is a model system for flows with a gas-liquid-gas interface. Also, understanding the soap bubble blowing process is practical because it can contribute to controlling industrial processes similar to soap bubble blowing. In this study, we visualized airflow which grows soap bubbles using the smoke wire technique to understand how airflow blows soap bubbles. The soap bubble blower setup was built to mimic the human blowing process of soap bubbles, which consists of a blower, a nozzle and a bubble ring. The smoke wire was placed between the nozzle and the bubble ring, and smoke-visualized airflow was captured using a high speed camera. Our visualization shows how air jet flows into the growing soap bubble on the ring and how the airflow interacts with the soap film of growing bubble.

  8. A derivation of the stable cavitation threshold accounting for bubble-bubble interactions.

    Science.gov (United States)

    Guédra, Matthieu; Cornu, Corentin; Inserra, Claude

    2017-09-01

    The subharmonic emission of sound coming from the nonlinear response of a bubble population is the most used indicator for stable cavitation. When driven at twice their resonance frequency, bubbles can exhibit subharmonic spherical oscillations if the acoustic pressure amplitude exceeds a threshold value. Although various theoretical derivations exist for the subharmonic emission by free or coated bubbles, they all rest on the single bubble model. In this paper, we propose an analytical expression of the subharmonic threshold for interacting bubbles in a homogeneous, monodisperse cloud. This theory predicts a shift of the subharmonic resonance frequency and a decrease of the corresponding pressure threshold due to the interactions. For a given sonication frequency, these results show that an optimal value of the interaction strength (i.e. the number density of bubbles) can be found for which the subharmonic threshold is minimum, which is consistent with recently published experiments conducted on ultrasound contrast agents. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. 'Multi-associations': predisposed to misinterpretation of peripheral tissue oxygenation and circulation in neonates.

    Science.gov (United States)

    Pichler, Gerhard; Pocivalnik, Mirjam; Riedl, Regina; Pichler-Stachl, Elisabeth; Morris, Nicholas; Zotter, Heinz; Müller, Wilhelm; Urlesberger, Berndt

    2011-08-01

    Interpretation of peripheral circulation in ill neonates is crucial but difficult. The aim was to analyse parameters potentially influencing peripheral oxygenation and circulation. In a prospective observational cohort study in 116 cardio-circulatory stable neonates, peripheral muscle near-infrared spectroscopy (NIRS) with venous occlusion was performed. Tissue oxygenation index (TOI), mixed venous oxygenation (SvO(2)), fractional oxygen extraction (FOE), fractional tissue oxygen extraction (FTOE), haemoglobin flow (Hbflow), oxygen delivery (DO(2)), oxygen consumption (VO(2)), and vascular resistance (VR) were assessed. Correlation coefficients between NIRS parameters and demographic parameters (gestational age, birth weight, age, actual weight, diameter of calf, subcutaneous adipose tissue), monitoring parameters (heart rate, arterial oxygen saturation (SaO(2)), mean blood pressure (MAP), core/peripheral temperature, central/peripheral capillary refill time) and laboratory parameters (haemoglobin concentration (Hb-blood), pCO(2)) were calculated. All demographic parameters except for Hbflow and DO(2) correlated with NIRS parameters. Heart rate correlated with TOI, SvO(2), VO(2) and VR. SaO(2) correlated with FOE/FTOE. MAP correlated with Hbflow, DO(2), VO(2) and VR. Core temperature correlated with FTOE. Peripheral temperature correlated with all NIRS parameters except VO(2). Hb-blood correlated with FOE and VR. pCO(2) levels correlated with TOI and SvO(2). The presence of multiple interdependent factors associated with peripheral oxygenation and circulation highlights the difficulty in interpreting NIRS data. Nevertheless, these findings have to be taken into account when analysing peripheral oxygenation and circulation data.

  10. Bubble nucleation in an explosive micro-bubble actuator

    International Nuclear Information System (INIS)

    Van den Broek, D M; Elwenspoek, M

    2008-01-01

    Explosive evaporation occurs when a thin layer of liquid reaches a temperature close to the critical temperature in a very short time. At these temperatures spontaneous nucleation takes place. The nucleated bubbles instantly coalesce forming a vapour film followed by rapid growth due to the pressure impulse. In this paper we take a closer look at the bubble nucleation. The moment of bubble nucleation was determined by both stroboscopic imaging and resistance thermometry. Two nucleation regimes could be distinguished. Several different heater designs were investigated under heat fluxes of hundreds of W mm −2 . A close correspondence between current density in the heater and point of nucleation was found. This results in design rules for effective heaters

  11. Aspherical bubble dynamics and oscillation times

    Energy Technology Data Exchange (ETDEWEB)

    Godwin, R.P.; Chapyak, E.J. [Los Alamos National Lab., NM (United States); Noack, J.; Vogel, A. [Medizinisches Laserzentrum Luebeck (Germany)

    1999-03-01

    The cavitation bubbles common in laser medicine are rarely perfectly spherical and are often located near tissue boundaries, in vessels, etc., which introduce aspherical dynamics. Here, novel features of aspherical bubble dynamics are explored. Time-resolved experimental photographs and simulations of large aspect ratio (length:diameter {approximately}20) cylindrical bubble dynamics are presented. The experiments and calculations exhibit similar dynamics. A small high-pressure cylindrical bubble initially expands radially with hardly any axial motion. Then, after reaching its maximum volume, a cylindrical bubble collapses along its long axis with relatively little radial motion. The growth-collapse period of these very aspherical bubbles differs only sightly from twice the Rayleigh collapse time for a spherical bubble with an equivalent maximum volume. This fact justifies using the temporal interval between the acoustic signals emitted upon bubble creation and collapse to estimate the maximum bubble volume. As a result, hydrophone measurements can provide an estimate of the bubble energy even for aspherical bubbles. The prolongation of the oscillation period of bubbles near solid boundaries relative to that of isolated spherical bubbles is also discussed.

  12. Numerical simulation of bubbles motion in lifting pipe of bubble pump for lithium bromide absorption chillers

    International Nuclear Information System (INIS)

    Gao, Hongtao; Liu, Bingbing; Yan, Yuying

    2017-01-01

    A bubble pump is proposed to replace the traditional mechanical solution pump in lithium bromide absorption chillers, for its advantageous feature that can be driven by industrial waste heat or solar energy or other low-grade energy. In two-stage bubble pump driven lithium bromide absorption refrigeration system, flow patterns in lifting pipe have significant effects on the performance of bubble pump. In this paper, the single bubble motion and the double bubbles coalescence in vertical ascending pipe are simulated by an improved free energy model of lattice Boltzmann method, in which the two-phase liquid to gas density ratio is 2778. The details of bubbles coalescence process are studied. Density and velocity of bubbles have been obtained. The computational results show that the initial radius of each bubble has a great influence on the coalescence time. The larger the initial bubble radius, the shorter the coalescence time. The pipe diameter has a little effect on the two bubbles coalescence time while it has a significant effect on the bubble velocity. As the pipe diameter increases, the bubble velocity increases. The obtained results are helpful for studying the transition mechanisms of two-phase flow patterns and useful for improving the bubble pump performance by controlling the flow patterns in lifting pipe.

  13. HCDA bubble experiment, (2)

    International Nuclear Information System (INIS)

    Sakata, Kaoru; Mashiko, Hiroyuki; Oka, Yoshiaki; An, Shigehiro; Isozaki, Tadashi.

    1981-06-01

    An experiment simulating the behavior of the very large steam bubbles generated at the time of an accident of core collapse was carried out with a warm water tank, and the applicability of the theory of very small bubble disappearance known at present was examined. The bubbles generated in HCDA (hypothetical core disruptive accident) are expected to be very large, containing sodium, fuel, FP gas and so on, and play important role in the mechanism of emitting radioactive substances in the safety analysis of LMFBRs. In this experiment, the degree of subcool of the warm water pool, the initial radii of steam bubbles and the blowoff pressure of steam were taken as the parameters. The radius of the steam bubbles generated in the experiment was about 6.5 cm, and the state of disappearance was different above and below the degree of unsaturation of 10 deg C. Comparing the disappearance curve obtained by the experiment with the theory of disappearance of small bubbles, the experimental values were between inertia-controlled disappearance and heat transfer-controlled disappearance, and this result was able to be explained generally with the model taking the pressure change within steam bubbles into account. The rise of bubbles was also observed. (Kako, I.)

  14. Study of droplet entrainment from bubbling surface in a bubble column

    International Nuclear Information System (INIS)

    Ramirez de Santiago, M.

    1991-05-01

    In a bubble column droplets are ejected from the free surface by bubble bursting or splashing. Depending on their size, the droplets are partly carried away by the streaming gas or fall back to the bubbling surface by gravity force. Experiments have been carried out to determine the void fraction in the column by means of an optical probe. In the interfacial zone the bubble bursting process was captured with a high-speed video camera. Simultaneous measurements were made of size and velocity of droplets at several distances from the bubbling surface with a Phase-Doppler Anemometry. The bubble column can be divided into three regions: A lower zone with a flat profile of the local void fraction, a central zone where the flow regime is steady and an upper zone where the local void fraction grows rapidly. A two-parameter log-normal distribution function was proposed in order to describe the polydisperse distribution of droplet-size. Results were obtained concerning the entrainment, concentration, volume fraction and interfacial area of droplets. Finally, it was found that the turbulence intensity affects the droplet terminal velocity for droplets smaller than the Kolmogorov microscale [fr

  15. Optimization of the bubble radius in a moving single bubble sonoluminescence

    International Nuclear Information System (INIS)

    Mirheydari, Mona; Sadighi-Bonabi, Rasoul; Rezaee, Nastaran; Ebrahimi, Homa

    2011-01-01

    A complete study of the hydrodynamic force on a moving single bubble sonoluminescence in N-methylformamide is presented in this work. All forces exerted, trajectory, interior temperature and gas pressure are discussed. The maximum values of the calculated components of the hydrodynamic force for three different radii at the same driving pressure were compared, while the optimum bubble radius was determined. The maximum value of the buoyancy force appears at the start of bubble collapse, earlier than the other forces whose maximum values appear at the moment of bubble collapse. We verified that for radii larger than the optimum radius, the temperature peak value decreases.

  16. Development of three-dimensional individual bubble-velocity measurement method by bubble tracking

    International Nuclear Information System (INIS)

    Kanai, Taizo; Furuya, Masahiro; Arai, Takahiro; Shirakawa, Kenetsu; Nishi, Yoshihisa

    2012-01-01

    A gas-liquid two-phase flow in a large diameter pipe exhibits a three-dimensional flow structure. Wire-Mesh Sensor (WMS) consists of a pair of parallel wire layers located at the cross section of a pipe. Both the parallel wires cross at 90o with a small gap and each intersection acts as an electrode. The WMS allows the measurement of the instantaneous two-dimensional void-fraction distribution over the cross-section of a pipe, based on the difference between the local instantaneous conductivity of the two-phase flow. Furthermore, the WMS can acquire a phasic-velocity on the basis of the time lag of void signals between two sets of WMS. Previously, the acquired phasic velocity was one-dimensional with time-averaged distributions. The authors propose a method to estimate the three-dimensional bubble-velocity individually WMS data. The bubble velocity is determined by the tracing method. In this tracing method, each bubble is separated from WMS signal, volume and center coordinates of the bubble is acquired. Two bubbles with near volume at two WMS are considered as the same bubble and bubble velocity is estimated from the displacement of the center coordinates of the two bubbles. The validity of this method is verified by a swirl flow. The proposed method can successfully visualize a swirl flow structure and the results of this method agree with the results of cross-correlation analysis. (author)

  17. Medical management of venous ulcers.

    Science.gov (United States)

    Pascarella, Luigi; Shortell, Cynthia K

    2015-03-01

    Venous disease is the most common cause of chronic leg ulceration and represents an advanced clinical manifestation of venous insufficiency. Due to their frequency and chronicity, venous ulcers have a high socioeconomic impact, with treatment costs accounting for 1% of the health care budget in Western countries. The evaluation of patients with venous ulcers should include a thorough medical history for prior deep venous thrombosis, assessment for an hypercoagulable state, and a physical examination. Use of the CEAP (clinical, etiology, anatomy, pathophysiology) Classification System and the revised Venous Clinical Severity Scoring System is strongly recommended to characterize disease severity and assess response to treatment. This venous condition requires lifestyle modification, with affected individuals performing daily intervals of leg elevation to control edema; use of elastic compression garments; and moderate physical activity, such as walking wearing below-knee elastic stockings. Meticulous skin care, treatment of dermatitis, and prompt treatment of cellulitis are important aspects of medical management. The pharmacology of chronic venous insufficiency and venous ulcers include essentially two medications: pentoxifylline and phlebotropic agents. The micronized purified flavonoid fraction is an effective adjunct to compression therapy in patients with large, chronic ulceration. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Diagnosis of venous disorders

    International Nuclear Information System (INIS)

    Minar, E.

    1993-01-01

    Limited accuracy in the clinic diagnosis of deep vein thrombosis (VT) makes such diagnostic tests such as duplex sonography or venography necessary. Exact information on the age and extent of the thrombus are necessary for the clinician to optimize the therapeutric management. The correct diagnosis of calf vein thrombosis and of recurrent VT in patients with postphlebitis changes also has implications for treatment. After exclusion of thrombosis, the radiologist should evaluate the leg for other possible causes of symptoms besides VT. Investigation of the venous sytem also has a role in the diagnosis in patients with suspected pulmonary embolism. In patients with chronic venous insuffficiency the deep venous system should assessed for patency and venous valve function. The superficial veins should be differentiated in segments with sufficient or insufficient venous valves, and it is also necessary to look for insufficiency of the perforrating veins. In patients with superficial phlebitis there is risk of propagation into the deep venous system. (orig.) [de

  19. Brain venous pathologies: MRI findings

    International Nuclear Information System (INIS)

    Salvatico, Rosana; Gonzalez, Alejandro; Yanez, Paulina; Romero, Carlos; Trejo, Mariano; Lambre, Hector

    2006-01-01

    Purpose: To describe MRI findings of the different brain venous pathologies. Material and Methods: Between January 2002 and March 2004, 18 patients were studied 10 males and 8 females between 6 and 63 years old; with different brain venous pathologies. In all cases brain MRI were performed including morphological sequences with and without gadolinium injection and angiographic venous sequences. Results: 10 venous occlusions were found, 6 venous angiomas, and 2 presented varices secondary to arteriovenous dural fistula. Conclusion: Brain venous pathologies can appear in many different clinical contexts, with different prognosis and treatment. In all the cases brain MRI was the best imaging study to disclose typical morphologic abnormalities. (author) [es

  20. Venous ulcers -- self-care

    Science.gov (United States)

    ... surgery to improve blood flow through your veins. Prevention If you are at risk for venous ulcers, take the steps listed above under Wound Care. ... weight if you are overweight. Manage your blood pressure and cholesterol levels. ... Venous leg ulcers - self-care; Venous insufficiency ulcers - self-care; Stasis ...

  1. Dynamics of bubble-bubble interaction in sheared low-viscosity magma imaged by X-ray computed micro-tomography

    Science.gov (United States)

    Helo, C.; Flaws, A.; Hess, K.-U.; Franz, A.; Clague, D. A.; Dingwell, D. B.

    2012-04-01

    X-ray computed tomography of vesicles in basaltic pyroclastic glass fragments has been used to investigate the syn-eruptive shear environment and resulting bubble-bubble interaction during mild pyroclastic eruptions in a mid-ocean ridge environment. We have imaged vesicles present in two different types of pyroclastic fragments produced by mildly explosive activity on Axial Seamount, limu o Pele, that is, thin glass films often described as bubble walls, and tube scoria fragments. Rapid quenching of the glass has prevented extensive bubble relaxation preserving the syn-eruptive geometry of the bubbles in these fragments. Isolated, ellipsoid-shaped vesicles in low-vesicular limu o Pele indicate deformation in a simple shear environment. Under these shear conditions higher vesiculated parts of the erupting magma show strong bubble-bubble interactions partially leading to coalscence and formation of tubular vesicles. These tubular vesicles can reach significant lengths, exceeding the dimensions of the small glass fragments (2 mm). Their unreformed radius can be more then one order of magnitude larger than that of the isolated vesicles in the limu o Pele fragments. We can distinguish two principle modes of interaction based on the relative orientation of the bubbles. Interaction along the sidewalls of two bubbles, and tip-to-tip interaction. At interdistances of less than a few tens of micrometre, interaction of the sidewalls results in deformation of the bubbles to more irregular shapes, with depressions caused by close, small bubbles or in some cases bubbles being partially mantled around tubular bubbles. This often leads to a more close packing of bubbles. At distances of less than a few microns, the melt films between the bubbles destabilize leading to coalescence. This mechanism appears to involve a bulging of the larger bubble into the smaller, followed by melt film rapture and coalescence. The complete digestion of one bubble by the other is the slow rate

  2. Fermi Bubble: Giant Gamma-Ray Bubbles in the Milky Way

    Science.gov (United States)

    Su, Meng

    Data from the Fermi-LAT reveal two gigantic gamma-ray emitting bubble structures (known as the Fermibubbles), extending˜50° above and below the Galactic center symmetric about the Galactic plane, with a width of˜40∘ in longitude. The gamma-ray emission associated with these bubbles has a significantly harder spectrum ({dN}/{dE} ˜ {E}^{-2}) than the inverse Compton emission from known cosmic ray electrons in the Galactic disk, or the gamma-rays produced by decay of pions from proton-ISM collisions. The bubbles are spatially correlated with the hard-spectrum microwave excess known as the WMAPhaze; the edges of the bubbles also line up with features in the ROSATsoft X-ray maps at 1.5-2keV. The Fermibubble is most likely created by some large episode of energy injection in the Galactic center, such as past accretion events onto the central massive black hole, or a nuclear starburst in the last˜10Myr. Study of the origin and evolution of the bubbles also has the potential to improve our understanding of recent energetic events in the inner Galaxy and the high-latitude cosmic ray population.

  3. Colliding with a crunching bubble

    Energy Technology Data Exchange (ETDEWEB)

    Freivogel, Ben; Freivogel, Ben; Horowitz, Gary T.; Shenker, Stephen

    2007-03-26

    In the context of eternal inflation we discuss the fate of Lambda = 0 bubbles when they collide with Lambda< 0 crunching bubbles. When the Lambda = 0 bubble is supersymmetric, it is not completely destroyed by collisions. If the domain wall separating the bubbles has higher tension than the BPS bound, it is expelled from the Lambda = 0 bubble and does not alter its long time behavior. If the domain wall saturates the BPS bound, then it stays inside the Lambda = 0 bubble and removes a finite fraction of future infinity. In this case, the crunch singularity is hidden behind the horizon of a stable hyperbolic black hole.

  4. Bubbles & Squat

    DEFF Research Database (Denmark)

    Højbjerre Larsen, Signe

    , a new concept called ‘Bubbles & Squat’, where fitness training is combined with Champagne and a live DJ. One of the invitations for this event describes how “we spice up your friday training with live DJ and lots of refreshing bubbles, to make sure that you are ready for the weekend (...).” Before New...

  5. A grid-independent EMMS/bubbling drag model for bubbling and turbulent fluidization

    DEFF Research Database (Denmark)

    Luo, Hao; Lu, Bona; Zhang, Jingyuan

    2017-01-01

    The EMMS/bubbling drag model takes the effects of meso-scale structures (i.e. bubbles) into modeling of drag coefficient and thus improves coarse-grid simulation of bubbling and turbulent fluidized beds. However, its dependence on grid size has not been fully investigated. In this article, we adopt...... a two-step scheme to extend the EMMS/bubbling model to the sub-grid level. Thus the heterogeneity index, HD, which accounts for the hydrodynamic disparity between homogeneous and heterogeneous fluidization, can be correlated as a function of both local voidage and slip velocity. Simulations over...... a periodic domain show the new drag model is less sensitive to grid size because of the additional dependence on local slip velocity. When applying the new drag model to simulations of realistic bubbling and turbulent fluidized beds, we find grid-independent results are easier to obtain for high...

  6. Models of the venous system

    DEFF Research Database (Denmark)

    Mehlsen, J

    2000-01-01

    Cardiac output is largely controlled by venous return, the driving force of which is the energy remaining at the postcapillary venous site. This force is influenced by forces acting close to the right atrium, and internally or externally upon the veins along their course. Analogue models of the v......Cardiac output is largely controlled by venous return, the driving force of which is the energy remaining at the postcapillary venous site. This force is influenced by forces acting close to the right atrium, and internally or externally upon the veins along their course. Analogue models...... of the venous system require at least three elements: a resistor, a capacitor and an inductor, with the latter being of more importance in the venous than in the arterial system. Non-linearities must be considered in pressure/flow relations in the small venules, during venous collapse, or low flow conditions...

  7. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    Science.gov (United States)

    Kropff, Jort; van Steen, Sigrid C; deGraaff, Peter; Chan, Man W; van Amstel, Rombout B E; DeVries, J Hans

    2017-11-01

    Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. We evaluated 21 individuals with type 1 diabetes using a capillary calibrated CGM system. Venous or arterialized-venous reference glucose samples were taken every 15 min at two separate visits and assessed per YSI 2300 STAT Plus. Arterialization was achieved by heated-hand technique. Capillary samples were collected hourly during the venous reference visit. The investigation sequence (venous or arterialized-venous) was randomized. Effectiveness of arterialization was measured by comparing free venous oxygen pressure (PO2) of both visit days. Primary endpoint was the median absolute relative difference (ARD). Median ARD using arterialized-venous reference samples was not different from venous samples (point estimated difference 0.52%, P = 0.181). When comparing the three reference methods, median ARD was also not different over the full glycemic range (venous 9.0% [n = 681], arterialized-venous 8.3% [n = 684], and capillary 8.1% [n = 205], P = 0.216), nor over the separate glucose ranges. Arterialization was successful (PO2 venous 5.4 kPa vs. arterialized-venous 8.9 kPa, P reference measurements did not significantly impact CGM accuracy. Venous reference seems preferable due to its ease of operation.

  8. Decompression illness - critical review

    Directory of Open Access Journals (Sweden)

    C S Mohanty

    2015-01-01

    Full Text Available Decompression illness is caused by intravascular or extravascular bubbles that are formed as a result of reduction in environmental pressure (decompression. The term covers both arterial gas embolism, in which alveolar gas or venous gas emboli (via cardiac shunts or via pulmonary vessels are introduced into the arterial circulation, and decompression sickness, which is caused by in-situ bubble formation from dissolved inert gas. Both syndromes can occur in divers, compressed air workers, aviators, and astronauts, but arterial gas embolism also arises from iatrogenic causes unrelated to decompression. Risk of decompression illness is affected by immersion, exercise, and heat or cold. Manifestations range from itching and minor pain to neurological symptoms, cardiac collapse, and death. First-aid treatment is 1 0 0 % oxygen and definitive treatment is recompression to increased pressure, breathing 1 0 0 % oxygen. Adjunctive treatment, including fluid administration and prophylaxis against venous thromboembolism in paralysed patients, is also recommended Treatment is, in most cases, effective although residual deficits can remain in serious cases, even after several recompressions.

  9. Joint pain and Doppler-detectable bubbles in altitude (Hypobaric) decompression

    Science.gov (United States)

    Powell, Michael R.

    1993-01-01

    The observation that altitude decompression sickness (DCS) is associated with pain in the lower extremities is not new, although it is not a consistent finding. DCS in divers is generally in the upper body, an effect often attributed to non-loading of the body while immersed. In caisson workers, DCS is reported more in the lower extremities. Surprisingly, many researchers do not mention the location of DCS joint pain, apparently considering it to be random. This is not the case for the tissue ratios encountered in studying decompression associated with simulated EVA. In NASA/JSC tests, altitude DCS generally presented first in either the ankle, knee, or hip (83 percent = 73/88). There was a definite statistical relation between the maximum Spencer precordial Doppler Grade and the incidence of DCS in the extremity, although this is not meant to imply a casual relation between circulating gas bubbles and joint pain. The risk of DCS with Grade 4 was considerably higher than that of Grades 0 to 3. The DCS risk was independent of the 'tissue ratio.' There was a predominance of lower extremity DCS even when exercise was performed with the upper body. The reason for these locations we hypothesize to be attributed to the formation of tissue gas micronuclei from kinetic and tensile forces (stress-assisted nucleation) and are the result of the individuals ambulating in a 1g environment. Additionally, since these showers of Doppler bubbles can persist for hours, it is difficult to imagine that they are emanating solely from tendons and ligaments, the supposed site of joint pain. This follows from Henry's law linking the volume of joint tissue (the solvent) and the solubility coefficient of inert gas; there is volumetrically insufficient connective tissue to produce the prolonged release of gas bubbles. If gas bubbles are spawned and released from connective tissue, their volume is increased by those from muscle tissue. Therefore, the nexus between Doppler-detectable gas

  10. Particle-bubble aggregate stability on static bubble generated by single nozzle on flotation process

    Science.gov (United States)

    Warjito, Harinaldi, Setyantono, Manus; Siregar, Sahala D.

    2016-06-01

    There are three sub-processes on flotation. These processes are intervening liquid film into critical thickness, rupture of liquid film forming three phase contact line, and expansion three phase contact line forming aggregate stability. Aggregate stability factor contribute to determine flotation efficiency. Aggregate stability has some important factors such as reagent and particle geometry. This research focussed on to understand effect of particle geometry to aggregate stability. Experimental setup consists of 9 x 9 x26 cm flotation column made of glass, bubble generator, particle feeding system, and high speed video camera. Bubble generator made from single nozzle with 0.3 mm diameter attached to programmable syringe pump. Particle feeding system made of pipette. Particle used in this research is taken from open pit Grasberg in Timika, Papua. Particle has sub-angular geometry and its size varies from 38 to 300 µm. Bubble-particle interaction are recorded using high speed video camera. Recordings from high speed video camera analyzed using image processing software. Experiment result shows that aggregate particle-bubble and induction time depends on particle size. Small particle (38-106 µm) has long induction time and able to rupture liquid film and also forming three phase contact line. Big particle (150-300 µm) has short induction time, so it unable to attach with bubble easily. This phenomenon is caused by apparent gravity work on particle-bubble interaction. Apparent gravity worked during particle sliding on bubble surface experience increase and reached its maximum magnitude at bubble equator. After particle passed bubble equator, apparent gravity force experience decrease. In conclusion particle size from 38-300 µm can form stable aggregate if particle attached with bubble in certain condition.

  11. Bubble transport in bifurcations

    Science.gov (United States)

    Bull, Joseph; Qamar, Adnan

    2017-11-01

    Motivated by a developmental gas embolotherapy technique for cancer treatment, we examine the transport of bubbles entrained in liquid. In gas embolotherapy, infarction of tumors is induced by selectively formed vascular gas bubbles that originate from acoustic vaporization of vascular droplets. In the case of non-functionalized droplets with the objective of vessel occlusion, the bubbles are transported by flow through vessel bifurcations, where they may split prior to eventually reach vessels small enough that they become lodged. This splitting behavior affects the distribution of bubbles and the efficacy of flow occlusion and the treatment. In these studies, we investigated bubble transport in bifurcations using computational and theoretical modeling. The model reproduces the variety of experimentally observed splitting behaviors. Splitting homogeneity and maximum shear stress along the vessel walls is predicted over a variety of physical parameters. Maximum shear stresses were found to decrease with increasing Reynolds number. The initial bubble length was found to affect the splitting behavior in the presence of gravitational asymmetry. This work was supported by NIH Grant R01EB006476.

  12. Treatment of micro air bubbles in rat adipose tissue at 25 kPa altitude exposures with perfluorocarbon emulsions and nitric oxide

    DEFF Research Database (Denmark)

    Randsøe, Thomas; Hyldegaard, O

    2014-01-01

    . The effect is ascribed to an increased solubility and transport capacity of respiratory gases in the PFC emulsion and possibly enhanced nitrogen washout through NO-increased blood flow rate and/or the removal of endothelial micro bubble nuclei precursors. Previous reports have shown that metabolic gases (i......INTRODUCTION: Perfluorocarbon emulsions (PFC) and nitric oxide (NO) releasing agents have on experimental basis demonstrated therapeutic properties in treating and preventing the formation of venous gas embolism as well as increased survival rate during decompression sickness from diving...

  13. Portal circulation following the Warren procedure. Long-term follow-up by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gostner, P; Fugazzola, C; Martin, F; Marzoli, G P

    1986-06-01

    Computed tomography with contrast injection was carried out in 18 patients who had undergone a Warren procedure for portal hypertension due to cirrhosis of the liver more than five years previously. The results show that it is not possible to drain only a part of the venous portal territory. The portal circulation does not consist of two portions, with different pressure relationships. Pressure difference across the splenorenal anastomosis is greater than that into the mediastinal veins. Postoperative development of a hepatofugal circulation continues for a long period and is not confined to the early phase only. This phenomenon is, however, not uniform. In particular, there are variations in the extent of the collateral circulation and in the maintenance of liver blood flow.

  14. Bubble Dynamics and Shock Waves

    CERN Document Server

    2013-01-01

    This volume of the Shock Wave Science and Technology Reference Library is concerned with the interplay between bubble dynamics and shock waves. It is divided into four parts containing twelve chapters written by eminent scientists. Topics discussed include shock wave emission by laser generated bubbles (W Lauterborn, A Vogel), pulsating bubbles near boundaries (DM Leppinen, QX Wang, JR Blake), interaction of shock waves with bubble clouds (CD Ohl, SW Ohl), shock propagation in polydispersed bubbly liquids by model equations (K Ando, T Colonius, CE Brennen. T Yano, T Kanagawa,  M Watanabe, S Fujikawa) and by DNS (G Tryggvason, S Dabiri), shocks in cavitating flows (NA Adams, SJ Schmidt, CF Delale, GH Schnerr, S Pasinlioglu) together with applications involving encapsulated bubble dynamics in imaging (AA Doinikov, A Novell, JM Escoffre, A Bouakaz),  shock wave lithotripsy (P Zhong), sterilization of ships’ ballast water (A Abe, H Mimura) and bubbly flow model of volcano eruptions ((VK Kedrinskii, K Takayama...

  15. Structure and kinematics of bubble flow; Structure et cinematique des ecoulements diphasiques a bulles

    Energy Technology Data Exchange (ETDEWEB)

    Lackme, C [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1967-07-01

    This report deals with the components and use of resistivity probes in bubble flow. With a single probe, we have studied the longitudinal and radial structure of the flow. The very complicated evolution of the radial structure is shown by the measurement of the mean bubble flux at several points in the tube. A double probe associated with a device the principle of which is given in this report, permits the measure of the local velocity of bubbles. Unlike the mean bubble flux profile, the change in the velocity profile along the tube is not significant. We have achieved the synthesis of these two pieces of information, mean local bubble flux and local velocity, by computing the mean weighed velocity in the tube. This weighed velocity compares remarkably with the velocity computed from the volumetric gas flow rate and the mean void fraction. (author) [French] Ce rapport traite d'une etude methodologique des ecoulements diphasiques a bulles. Les fluides sont l'air et l'eau, ils circulent du bas vers le haut dans un tube vertical de 32 mm de diametre et 2 metres de long. Cette etude a pour but de permettre une description fine de l'ecoulement. Pour cela, il a ete necessaire de developper des appareillages nouveaux et de mettre au point les methodes d'analyses correspondantes. La valeur des mesures effectuees et des methodes utilisees apparait dans une comparaison concluante et conclusive entre des resultats de mesures globales et des resultats integres de mesures locales. (auteur)

  16. Bubble Coalescence: Effect of Bubble Approach Velocity and Liquid Viscosity

    Czech Academy of Sciences Publication Activity Database

    Orvalho, Sandra; Růžička, Marek; Olivieri, G.; Marzocchella, A.

    2015-01-01

    Roč. 134, SEP 29 (2015), s. 205-216 ISSN 0009-2509 R&D Projects: GA MŠk(CZ) LD13018 Institutional support: RVO:67985858 Keywords : bubble coalescence * bubble approach velocity * liquid viscosity Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 2.750, year: 2015

  17. Bubble propagation on a rail: a concept for sorting bubbles by size

    Science.gov (United States)

    Franco-Gómez, Andrés; Thompson, Alice B.; Hazel, Andrew L.; Juel, Anne

    We demonstrate experimentally that the introduction of a rail, a small height constriction, within the cross-section of a rectangular channel could be used as a robust passive sorting device in two-phase fluid flows. Single air bubbles carried within silicone oil are generally transported on one side of the rail. However, for flow rates marginally larger than a critical value, a narrow band of bubble sizes can propagate (stably) over the rail, while bubbles of other sizes segregate to the side of the rail. The width of this band of bubble sizes increases with flow rate and the size of the most stable bubble can be tuned by varying the rail width. We present a complementary theoretical analysis based on a depth-averaged theory, which is in qualitative agreement with the experiments. The theoretical study reveals that the mechanism relies on a non-trivial interaction between capillary and viscous forces that is fully dynamic, rather than being a simple modification of capillary static solutions.

  18. A study of atriphos (ATP) action on muscular circulation in progressive muscular dystrophy by the radioactive xenon clearance technique

    International Nuclear Information System (INIS)

    Chakyrov, B.; Samardzhiev, A.

    1977-01-01

    The effect of intramuscularly and intravenously adminostered atriphos on the muscular circulation was studied with radioactive xenon in 12 children with progressive muscular dystrophy. After combined local intramuscular injection of ATP (atriphos) with the radioactive marker a 12-fold increment of muscular circulation ensues, lasting about 15 minutes. No vasodilatating effect on the muscular flow was oberved after intravenous injection of 20-40 mg of atriphos. It is believed that intramuscular administration of atriphos produced dilatation of capillaries and of the venous part of the muscular circulation. (author)

  19. Bubble Formation in Basalt-like Melts

    DEFF Research Database (Denmark)

    Jensen, Martin; Keding, Ralf; Yue, Yuanzheng

    2011-01-01

    and their diameter. The variation in melting temperature has little influence on the overall bubble volume. However, the size distribution of the bubbles varies with the melting temperature. When the melt is slowly cooled, the bubble volume increases, implying decreased solubility of the gaseous species. Mass...... spectroscopy analysis of gases liberated during heating of the glass reveals that small bubbles contain predominantly CH4, CO and CO2, whereas large bubbles bear N2, SO2 and H2S. The methodology utilised in this work can, besides mapping the bubbles in a glass, be applied to shed light on the sources of bubble...

  20. Prophylaxis of Venous Thrombosis.

    Science.gov (United States)

    Goldhaber, Samuel Z.

    2001-06-01

    Mechanical measures such as graduated compression stockings and intermittent compression boots are available for venous thrombosis prophylaxis, but compliance may be limited. Plantar venous pneumatic compression devices have attained widespread acceptance by both patients and nurses because of their comfort and compact size, but their track record for efficacy is poor. Inferior vena cava filters prevent pulmonary embolism, but do not halt the thrombotic process or prevent venous thrombosis. Pharmacologic prophylaxis traditionally has relied upon minidose unfractionated heparin; however, re-examination is warranted in the face of increasingly ill and complex patients. My opinion is that small, fixed doses of once-daily low molecular weight heparin will eventually replace minidose unfractionated heparin as the standard pharmacologic prophylaxis regimen for most surgical and medical patients. Prolongation of prophylaxis after hospital discharge should receive increased emphasis. Most patients being transferred to a skilled nursing facility should receive venous thromboembolism prophylaxis. Similarly, most patients undergoing total hip or knee replacement should receive prolonged preventive regimens, with at least 1 month of anticoagulation. Despite advances, certain aspects of venous thrombosis prophylaxis remain problematic. First, a surprisingly high number of hospitalized patients develop venous thrombosis because of failed (rather than omitted) prophylaxis. Second, many patients in intensive care have a combination of peripheral vascular disease and active bleeding (usually gastrointestinal) that precludes mechanical or pharmacologic prophylaxis. Third, neurosurgical patients undergoing craniotomy for brain tumors suffer a high rate of venous thrombosis and major pulmonary embolism despite the routine use of combined mechanical and pharmacologic prophylaxis. My opinion is that these three areas, in addition to the hospital culture of prophylaxis, should receive

  1. 'Multi-associations': predisposed to misinterpretation of peripheral tissue oxygenation and circulation in neonates

    International Nuclear Information System (INIS)

    Pichler, Gerhard; Pocivalnik, Mirjam; Pichler-Stachl, Elisabeth; Morris, Nicholas; Zotter, Heinz; Müller, Wilhelm; Urlesberger, Berndt; Riedl, Regina

    2011-01-01

    Interpretation of peripheral circulation in ill neonates is crucial but difficult. The aim was to analyse parameters potentially influencing peripheral oxygenation and circulation. In a prospective observational cohort study in 116 cardio-circulatory stable neonates, peripheral muscle near-infrared spectroscopy (NIRS) with venous occlusion was performed. Tissue oxygenation index (TOI), mixed venous oxygenation (SvO 2 ), fractional oxygen extraction (FOE), fractional tissue oxygen extraction (FTOE), haemoglobin flow (Hbflow), oxygen delivery (DO 2 ), oxygen consumption (VO 2 ), and vascular resistance (VR) were assessed. Correlation coefficients between NIRS parameters and demographic parameters (gestational age, birth weight, age, actual weight, diameter of calf, subcutaneous adipose tissue), monitoring parameters (heart rate, arterial oxygen saturation (SaO 2 ), mean blood pressure (MAP), core/peripheral temperature, central/peripheral capillary refill time) and laboratory parameters (haemoglobin concentration (Hb-blood), pCO 2 ) were calculated. All demographic parameters except for Hbflow and DO 2 correlated with NIRS parameters. Heart rate correlated with TOI, SvO 2 , VO 2 and VR. SaO 2 correlated with FOE/FTOE. MAP correlated with Hbflow, DO 2 , VO 2 and VR. Core temperature correlated with FTOE. Peripheral temperature correlated with all NIRS parameters except VO 2 . Hb-blood correlated with FOE and VR. pCO 2 levels correlated with TOI and SvO 2 . The presence of multiple interdependent factors associated with peripheral oxygenation and circulation highlights the difficulty in interpreting NIRS data. Nevertheless, these findings have to be taken into account when analysing peripheral oxygenation and circulation data

  2. Experimental study of vapor bubble dynamics

    International Nuclear Information System (INIS)

    Pasquini, Maria-Elena

    2015-01-01

    The object of this thesis is an experimental study of vapor bubble dynamics in sub-cooled nucleate boiling. The test section is locally heated by focusing a laser beam: heat fluxes from 1 e4 to 1.5 e6 W/m 2 and water temperature between 100 and 88 C have been considered. Three boiling regimes have been observed. Under saturated conditions and with low heat fluxes a developed nucleate boiling regime has been observed. Under higher sub-cooling and still with low heat fluxes an equilibrium regime has been observed in which the liquid flowrate evaporating at the bubble base is compensated by the vapor condensing flowrate at bubble top. A third regime have been observed at high heat fluxes for all water conditions: it is characterized by the formation of a large dry spot on the heated surface that keeps the nucleation site dry after bubble detachment. The condensation phase starts after bubble detachment. Bubble equivalent radius at detachment varies between 1 and 2.5 mm. Bubble properties have been measured and non-dimensional groups have been used to characterize bubble dynamics. Capillary waves have been observed on the bubble surface thanks to high-speed images acquisition. Two main phenomena have been proposed to explain capillary waves effects on bubble condensation: increasing of the phases interface area and decreasing of vapor bubble translation velocity, because of the increased drag force on the deformed bubble. (author) [fr

  3. Guidelines for clinical studies with compression devices in patients with venous disorders of the lower limb.

    Science.gov (United States)

    Rabe, E; Partsch, H; Jünger, M; Abel, M; Achhammer, I; Becker, F; Cornu-Thenard, A; Flour, M; Hutchinson, J; Issberner, K; Moffatt, Ch; Pannier, F

    2008-04-01

    The scientific quality of published clinical trials is generally poor in studies where compression devices have been assessed in the management of venous disease. The authors' aim was to establish a set of guidelines which could be used in the design of future clinical trials of compression treatments for venous diseases. Consensus conference leading to a consensus statement. The authors form a expert consensus group known as the International Compression Club (ICC). This group obtained published medical literature in the field of compression treatment in venous disease by searching medical literature databases. The literature was studied by the group which attended a consensus meeting. A draft document was circulated to ICC members and revised until agreement between contributors was reached. The authors have prepared a set of guidelines which should be given consideration when conducting studies to assess the efficacy of compression in venous disease. The form of compression therapy including the comparators used in the clinical study must be clearly characterised. In future studies the characteristics of the material provided by the manufacturer should be described including in vivo data on pressure and stiffness of the final compression system. The pressure exerted on the distal lower leg should be stated in mmHg and the method of pressure determination must be quoted.

  4. Single bubble sonoluminescence

    NARCIS (Netherlands)

    Brenner, Michael P.; Hilgenfeldt, Sascha; Lohse, Detlef

    2002-01-01

    Single-bubble sonoluminescence occurs when an acoustically trapped and periodically driven gas bubble collapses so strongly that the energy focusing at collapse leads to light emission. Detailed experiments have demonstrated the unique properties of this system: the spectrum of the emitted light

  5. Bubble dynamics equations in Newton fluid

    International Nuclear Information System (INIS)

    Xiao, J

    2008-01-01

    For the high-speed flow of Newton fluid, bubble is produced and expanded when it moves toward the surface of fluid. Bubble dynamics is a very important research field to understand the intrinsic feature of bubble production and motion. This research formulates the bubble expansion by expansion-local rotation transformation, which can be calculated by the measured velocity field. Then, the related dynamic equations are established to describe the interaction between the fluid and the bubble. The research shows that the bubble production condition can be expressed by critical vortex value and fluid pressure; and the bubble expansion rate can be obtained by solving the non-linear dynamic equation of bubble motion. The results may help the related research as it shows a special kind of fluid motion in theoretic sense. As an application example, the nanofiber radium-voltage relation and threshold voltage-surface tension relation in electrospinning process are discussed

  6. Bidirectional cinematography of steam-bubble growth

    Energy Technology Data Exchange (ETDEWEB)

    Deason, V.A.; Reynolds, L.D.

    1982-01-01

    Single steam bubbles were generated in superheated water in an optical cell. The growth process of the bubbles was recorded with a high-speed motion picture camera at 5000 and 10,000 frames per second. A technique was developed to simultaneously image two orthogonal views of the bubbles on each frame of film. The vertical and horizontal diameters of the bubbles were measured on a frame-by-frame basis, and the data analyzed to determine oscillatory frequencies. The analysis also attempted to determine whether the bubbles were undergoing volumetric oscillations during early growth or whether simple surface wave/rotational behavior caused the observed periodic variations in bubble dimensions. For the bubbles studied, typical oscillation frequencies for the diameters were in the range of 100 to 500 Hz.

  7. Bidirectional cinematography of steam-bubble growth

    International Nuclear Information System (INIS)

    Deason, V.A.; Reynolds, L.D.

    1982-01-01

    Single steam bubbles were generated in superheated water in an optical cell. The growth process of the bubbles was recorded with a high-speed motion picture camera at 5000 and 10,000 frames per second. A technique was developed to simultaneously image two orthogonal views of the bubbles on each frame of film. The vertical and horizontal diameters of the bubbles were measured on a frame-by-frame basis, and the data analyzed to determine oscillatory frequencies. The analysis also attempted to determine whether the bubbles were undergoing volumetric oscillations during early growth or whether simple surface wave/rotational behavior caused the observed periodic variations in bubble dimensions. For the bubbles studied, typical oscillation frequencies for the diameters were in the range of 100 to 500 Hz

  8. An equation of motion for bubble growth

    International Nuclear Information System (INIS)

    Lesage, F.J.; Cotton, J.S.; Robinson, A.J.

    2009-01-01

    A mathematical model is developed which describes asymmetric bubble growth, either during boiling or bubble injection from submerged orifices. The model is developed using the integral form of the continuity and momentum equations, resulting in a general expression for the acceleration of the bubble's centre of gravity. The proposed model highlights the need to include acceleration due to an asymmetric gain or loss of mass in order to accurately predict bubble motion. Some scenarios are posed by which the growth of bubbles, particularly idealized bubbles that remain a section of a sphere, must include the fact that bubble growth can be asymmetric. In particular, for approximately hemispherical bubble growth the sum of the forces acting on the bubble is negligible compared with the asymmetric term. Further, for bubble injection from a submerged needle this component in the equation of motion is very significant during the initial rapid growth phase as the bubble issues from the nozzle changing from a near hemisphere to truncated sphere geometry. (author)

  9. Study of stream flow effects on bubble motion

    International Nuclear Information System (INIS)

    Sami, S.S.

    1983-01-01

    The formation of air bubbles at constant-pressure by submerged orifices was investigated in both quiescent and moving streams inside a vertical tube. Parameters affecting the bubble rise velocity, such as bubble generating frequency and diameter, were studied and analyzed for bubbles rising in a chain and homogeneous mixture. A special technique for measuring bubble motion parameters has been developed, tested, and employed throughout the experimental investigation. The method is based on a water-air impedance variation. Results obtained in stagnant liquid show that increasing the bubble diameter serves to increase bubble rise velocity, while an opposite trend has been observed for stream liquid where the bubble diameter increase reduces the bubble rise velocity. The increase of bubble generation frequency generally increases the bubble rise velocity. Experimental data covered with bubble radial distribution showed symmetrical profiles of bubble velocity and frequency, and the radial distribution of the velocity profiles sometimes has two maxima and one minimum depending on the liquid velocity. Finally, in stagnant liquid, a normalized correlation has been developed to predict the terminal rise velocity in terms of bubble generating frequency, bubble diameter, single bubble rise velocity, and conduit dimensions. Another correlation is presented for forced bubbly flow, where the bubble rise velocity is expressed as a function of bubble generating frequency, bubble diameter, and water superficial velocity

  10. Parenchymal abnormalities in cerebral venous thrombosis: findings of magnetic resonance imaging and magnetic resonance angiography

    International Nuclear Information System (INIS)

    Ferreira, Clecia Santos; Pellini, Marcos; Boasquevisque, Edson; Souza, Luis Alberto M. de

    2006-01-01

    Objective: to determine the frequency and localization of parenchymal abnormalities in cerebral venous thrombosis on magnetic resonance imaging and magnetic resonance angiography as well as their correlation with the territory and affected venous drainage. Materials and methods: retrospective analysis (1996 to 2004) of 21 patients (3 male and 18 female) age range between 3 and 82 years (mean 40 years, median 36 years) with clinical and radiological diagnosis of cerebral venous thrombosis on magnetic resonance imaging and magnetic resonance angiography in 2D PC, 3D PC and contrast-enhanced 3D TOF sequences. The statistical analysis was performed with the qui-square test. Four patients had follow-up exams and three patients underwent digital subtraction angiography. Results: main predisposing factors were: infection, use of oral contraceptives, hormone replacement therapy and collagenosis. Predominant symptoms included: focal deficit, headache, alteration of consciousness level and seizures. Most frequent parenchymal manifestations were: cortical/subcortical edema or infarct, venous congestion and collateral circulation, meningeal enhancement and thalamic and basal ganglia edema or infarct. Occlusion occurred mainly in superior sagittal, left transverse, left sigmoid and straight sinuses. Cavernous sinus and cortical veins thrombosis are uncommon events. Conclusion: cerebral venous thrombosis is an uncommon cause of stroke, with favorable prognosis because of its reversibility. Diagnosis is highly dependent on the radiologist capacity to recognize the presentations of this disease, principally in cases where the diagnosis is suggested by parenchymal abnormalities rather than necessarily by visualization of the thrombus itself. An accurate and rapid diagnosis allows an immediate treatment, reducing the morbidity and mortality rates. (author)

  11. Bubbles in graphene

    DEFF Research Database (Denmark)

    Settnes, Mikkel; Power, Stephen; Lin, Jun

    2015-01-01

    Strain-induced deformations in graphene are predicted to give rise to large pseudomagnetic fields. We examine theoretically the case of gas-inflated bubbles to determine whether signatures of such fields are present in the local density of states. Sharp-edged bubbles are found to induce Friedel...

  12. Growth process of helium bubbles in aluminium

    International Nuclear Information System (INIS)

    Shiraishi, Haruki; Sakairi, Hideo; Yagi, Eiichi; Karasawa, Takashi; Hashiguti, R.R.

    1975-01-01

    The growth process of helium bubbles in α-particle bombarded pure aluminum during isothermal anneal ranging 200 to 645 0 C and 1 to 100 hr was observed by a transmission electron microscope and the possible growth mechanisms are discussed. The effects of helium concentration and cold work were investigated. The helium bubbles are detectable only at the anneal above 550 0 C in both annealed and cold worked samples. The cold work does not cause any extra coarsening trend of bubbles. The observed types of bubble distribution in the grain interior are divided into two categories, irrespective of helium concentration and cold work; (1) the fine and uniform bubble distribution, in which case the average size is limited to about 200 A or less in diameter even at the anneal just below the melting point, and (2) the coarsened and non-uniform bubble distribution ranging 500 to 4000 A in diameter. The intermediate size bubbles are scarcely found in any cases. In the above fine bubble distribution, the increase of helium concentration by a factor of two increases the density by the same factor of two, but does not change the mean size of bubbles. Corresponding to the above two characteristic bubble distributions, it is concluded that two different mechanisms are operative in this experiment; (1) the growth of bubbles by the Brownian motion, in which the growth rate of bubbles is decreased to almost zero by bubble faceting and this results in the bubble size constancy during the prolonged annealing, and (2) the growth of bubbles by the grain boundary sweep-out mechanism, by which the abrupt coarsening of bubbles is caused. The lack of existence of the intermediate size bubbles is explained in this way. (auth.)

  13. Vasopressin-induced changes in splanchnic blood flow and hepatic and portal venous pressures in liver resection.

    Science.gov (United States)

    Bown, L Sand; Ricksten, S-E; Houltz, E; Einarsson, H; Söndergaard, S; Rizell, M; Lundin, S

    2016-05-01

    To minimize blood loss during hepatic surgery, various methods are used to reduce pressure and flow within the hepato-splanchnic circulation. In this study, the effect of low- to moderate doses of vasopressin, a potent splanchnic vasoconstrictor, on changes in portal and hepatic venous pressures and splanchnic and hepato-splanchnic blood flows were assessed in elective liver resection surgery. Twelve patients were studied. Cardiac output (CO), stroke volume (SV), mean arterial (MAP), central venous (CVP), portal venous (PVP) and hepatic venous pressures (HVP) were measured, intraoperatively, at baseline and during vasopressin infusion at two infusion rates (2.4 and 4.8 U/h). From arterial and venous blood gases, the portal (splanchnic) and hepato-splanchnic blood flow changes were calculated, using Fick's equation. CO, SV, MAP and CVP increased slightly, but significantly, while systemic vascular resistance and heart rate remained unchanged at the highest infusion rate of vasopressin. PVP was not affected by vasopressin, while HVP increased slightly. Vasopressin infusion at 2.4 and 4.8 U/h reduced portal blood flow (-26% and -37%, respectively) and to a lesser extent hepato-splanchnic blood flow (-9% and -14%, respectively). The arterial-portal vein lactate gradient was not significantly affected by vasopressin. Postoperative serum creatinine was not affected by vasopressin. Short-term low to moderate infusion rates of vasopressin induced a splanchnic vasoconstriction without metabolic signs of splanchnic hypoperfusion or subsequent renal impairment. Vasopressin caused a centralization of blood volume and increased cardiac output. Vasopressin does not lower portal or hepatic venous pressures in this clinical setting. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  14. Nuttier bubbles

    International Nuclear Information System (INIS)

    Astefanesei, Dumitru; Mann, Robert B.; Stelea, Cristian

    2006-01-01

    We construct new explicit solutions of general relativity from double analytic continuations of Taub-NUT spacetimes. This generalizes previous studies of 4-dimensional nutty bubbles. One 5-dimensional locally asymptotically AdS solution in particular has a special conformal boundary structure of AdS 3 x S 1 . We compute its boundary stress tensor and relate it to the properties of the dual field theory. Interestingly enough, we also find consistent 6-dimensional bubble solutions that have only one timelike direction. The existence of such spacetimes with non-trivial topology is closely related to the existence of the Taub-NUT(-AdS) solutions with more than one NUT charge. Finally, we begin an investigation of generating new solutions from Taub-NUT spacetimes and nuttier bubbles. Using the so-called Hopf duality, we provide new explicit time-dependent backgrounds in six dimensions

  15. Fragment E1 labeled with I-123 in the detection of venous thrombosis

    International Nuclear Information System (INIS)

    Knight, L.C.; Maurer, A.H.; Robbins, P.S.; Malmud, L.S.; Budzynski, A.Z.

    1985-01-01

    Fragment E1, which has been shown to have specific binding affinity for thrombi in an animal model, was investigated in humans for its safety and ability to bind to venous thrombi. Human Fragment E1 was labeled with I-123 and administered intravenously to patients with proved or suspected deep vein thrombosis. The vascular distribution of radioactivity was documented by obtaining gamma camera images of the patients' legs for 30 minutes following administration of I-123-Fragment E1. All patients (n = 5) with documented venous thrombi had rapid localization of labeled Fragment E1 in the area of thrombus. Patients without evidence of thrombi (n = 5) showed no focal localization, although two of these patients showed diffuse uptake along the length of the veins, due to superficial phlebitis. Analysis of blood samples in four patients indicated that disappearance of Fragment E1 from the circulation was more rapid in individuals with thrombosis (t 1/2 = 20 min) than in individuals without thrombosis (t 1/2 = 90 min), and a radiolabeled species of high molecular weight was found in patients with thrombosis but was absent from patients without thrombosis. These early results suggest that radiolabeled Fragment E1 is a safe and potentially valuable agent for the rapid detection of venous thrombosis

  16. Interaction mechanism of double bubbles in hydrodynamic cavitation

    Science.gov (United States)

    Li, Fengchao; Cai, Jun; Huai, Xiulan; Liu, Bin

    2013-06-01

    Bubble-bubble interaction is an important factor in cavitation bubble dynamics. In this paper, the dynamic behaviors of double cavitation bubbles driven by varying pressure field downstream of an orifice plate in hydrodynamic cavitation reactor are examined. The bubble-bubble interaction between two bubbles with different radii is considered. We have shown the different dynamic behaviors between double cavitation bubbles and a single bubble by solving two coupling nonlinear equations using the Runge-Kutta fourth order method with adaptive step size control. The simulation results indicate that, when considering the role of the neighbor smaller bubble, the oscillation of the bigger bubble gradually exhibits a lag in comparison with the single-bubble case, and the extent of the lag becomes much more obvious as time goes by. This phenomenon is more easily observed with the increase of the initial radius of the smaller bubble. In comparison with the single-bubble case, the oscillation of the bigger bubble is enhanced by the neighbor smaller bubble. Especially, the pressure pulse of the bigger bubble rises intensely when the sizes of two bubbles approach, and a series of peak values for different initial radii are acquired when the initial radius ratio of two bubbles is in the range of 0.9˜1.0. Although the increase of the center distance between two bubbles can weaken the mutual interaction, it has no significant influence on the enhancement trend. On the one hand, the interaction between two bubbles with different radii can suppress the growth of the smaller bubble; on the other hand, it also can enhance the growth of the bigger one at the same time. The significant enhancement effect due to the interaction of multi-bubbles should be paid more attention because it can be used to reinforce the cavitation intensity for various potential applications in future.

  17. Circulating Elastin Fragments Are Not Affected by Hepatic, Renal and Hemodynamic Changes, But Reflect Survival in Cirrhosis with TIPS.

    Science.gov (United States)

    Nielsen, M J; Lehmann, J; Leeming, D J; Schierwagen, R; Klein, S; Jansen, C; Strassburg, C P; Bendtsen, F; Møller, S; Sauerbruch, T; Karsdal, M A; Krag, A; Trebicka, J

    2015-11-01

    Progressive fibrosis increases hepatic resistance and causes portal hypertension with complications. During progressive fibrosis remodeling and deposition of collagens and elastin occur. Elastin remodeling is crucially involved in fibrosis progression in animal models and human data. This study investigated the association of circulating elastin with the clinical outcome in cirrhotic patients with severe portal hypertension receiving transjugular intrahepatic porto-systemic shunt (TIPS). We analyzed portal and hepatic venous samples of 110 cirrhotic patients obtained at TIPS insertion and 2 weeks later. The circulating levels of elastin fragments (ELM) were determined using specific monoclonal ELISA. The relationship of ELM with clinical short-time follow-up and long-term outcome was investigated. Circulating levels of ELM showed a gradient across the liver before TIPS with higher levels in the hepatic vein. Interestingly, the circulating ELM levels remained unchanged after TIPS. The circulating levels of ELM in portal and hepatic veins correlated with platelet counts and inversely with serum sodium. Hepatic venous levels of ELM were higher in CHILD C compared to CHILD A and B and were associated with the presence of ascites. Patients with high levels of ELM in the hepatic veins before TIPS showed poorer survival. In multivariate analysis ELM levels in the hepatic veins and MELD were independent predictors of mortality in these patients. This study demonstrated that circulating levels of ELM are not associated with hemodynamic changes, but might reflect fibrosis remodeling and predict survival in patients with severe portal hypertension receiving TIPS independently of MELD.

  18. An equation of motion for bubble growth

    Energy Technology Data Exchange (ETDEWEB)

    Lesage, F.J. [College d' Enseignement General et Professionnel de L' Outaouais, Gatineau, Quebec (Canada). Dept. of Mathematics; Cotton, J.S. [McMaster University, Hamilton, ON (Canada). Dept. of Mechanical Engineering; Robinson, A.J. [Trinity College Dublin (Ireland). Dept. of Mechanical and Manufacturing Engineering

    2009-07-01

    A mathematical model is developed which describes asymmetric bubble growth, either during boiling or bubble injection from submerged orifices. The model is developed using the integral form of the continuity and momentum equations, resulting in a general expression for the acceleration of the bubble's centre of gravity. The proposed model highlights the need to include acceleration due to an asymmetric gain or loss of mass in order to accurately predict bubble motion. Some scenarios are posed by which the growth of bubbles, particularly idealized bubbles that remain a section of a sphere, must include the fact that bubble growth can be asymmetric. In particular, for approximately hemispherical bubble growth the sum of the forces acting on the bubble is negligible compared with the asymmetric term. Further, for bubble injection from a submerged needle this component in the equation of motion is very significant during the initial rapid growth phase as the bubble issues from the nozzle changing from a near hemisphere to truncated sphere geometry. (author)

  19. Complications of central venous stenosis due to permanent central venous catheters in children on hemodialysis.

    Science.gov (United States)

    Rinat, Choni; Ben-Shalom, Efrat; Becker-Cohen, Rachel; Feinstein, Sofia; Frishberg, Yaacov

    2014-11-01

    Central venous catheters are frequently used as access for hemodialysis (HD) in children. One of the known complications is central venous stenosis. Although this complication is not rare, it is often asymptomatic and therefore unacknowledged. Superior vena cava (SVC) stenosis is obviously suspected in the presence of upper body edema, but several other signs and symptoms are often unrecognized as being part of this syndrome. We describe four patients with various manifestations of central venous stenosis and SVC syndrome. These sometimes life- or organ-threatening conditions include obstructive sleep apnea, unresolving stridor, increased intracranial pressure, increased intraocular pressure, right-sided pleural effusion, protein-losing enteropathy and lymphadenopathy. The temporal relationship of these complications associated with the use of central venous catheters and documentation of venous stenosis, together with their resolution after alleviation of high venous pressure, points to a causal role. We suggest pathophysiological mechanisms for the formation of each of these complications. In patients with occlusion of the SVC, various unexpected clinical entities can be caused by high central venous pressure. As often the etiology is not obvious, a high index of suspicion is needed as in some cases prompt alleviation of the high pressure is mandatory.

  20. Computing bubble-points of CO

    NARCIS (Netherlands)

    Ramdin, M.; Balaji, S.P.; Vicent Luna, J.M.; Torres-Knoop, A; Chen, Q.; Dubbeldam, D.; Calero, S; de Loos, T.W.; Vlugt, T.J.H.

    2016-01-01

    Computing bubble-points of multicomponent mixtures using Monte Carlo simulations is a non-trivial task. A new method is used to compute gas compositions from a known temperature, bubble-point pressure, and liquid composition. Monte Carlo simulations are used to calculate the bubble-points of

  1. Bubble bursting at an interface

    Science.gov (United States)

    Kulkarni, Varun; Sajjad, Kumayl; Anand, Sushant; Fezzaa, Kamel

    2017-11-01

    Bubble bursting is crucial to understanding the life span of bubbles at an interface and more importantly the nature of interaction between the bulk liquid and the outside environment from the point of view of chemical and biological material transport. The dynamics of the bubble as it rises from inside the liquid bulk to its disappearance on the interface after bursting is an intriguing process, many aspects of which are still being explored. In our study, we make detailed high speed imaging measurements to examine carefully the hole initiation and growth in bursting bubbles that unearth some interesting features of the process. Previous analyses available in literature are revisited based on our novel experimental visualizations. Using a combination of experiments and theory we investigate the role of various forces during the rupturing process. This work aims to further our current knowledge of bubble dynamics at an interface with an aim of predicting better the bubble evolution from its growth to its eventual integration with the liquid bulk.

  2. Vascular anomalies in the mesenteric circulation of patients with Crohn’s disease: a pilot study

    Directory of Open Access Journals (Sweden)

    Matilde Zamboni

    2017-07-01

    Full Text Available Crohn’s disease (CD is a chronic inflammatory bowel disease and its pathogenesis is still not well understood. Previous studies suggested the possibility of the involvement of vascular system, but, todate, the mesenteric circulation has poor been investigated, especially in complicated CD cases requiring colectomy. We investigated the mesenteric circulation in a case-control pilot study, including 19 controls and 7 patients affected by complicated cases of CD. Cases and controls underwent selective angiography of both superior and inferior mesenteric district. Transit time was found either significantly shortened in 2/7 cases (29%, or prolonged 5/7 (71% (P=0.0034 in the superior mesenteric district; P=0.0079 in the inferior mesenteric district, respectively due to the presence of A-V malformations and of a miscellaneous of venous abnormalities, which included thrombosis, hypoplasia and extra-truncular venous malformations. Our study demonstrates the presence of congenital or acquired vascular anomalies in a small sample of CD patients not responder to current treatment and with severe complications. The present pilot study warrants further investigations.

  3. Scales and structures in bubbly flows. Experimental analysis of the flow in bubble columns and in bubbling fluidized beds

    NARCIS (Netherlands)

    Groen, J.S.

    2004-01-01

    In this project a detailed experimental analysis was performed of the dynamic flow field in bubbly flows, with the purpose of determining local hydrodynamics and scale effects. Measurements were done in gas-liquid systems (air-water bubble columns) and in gas-solid systems (air-sand bubbing

  4. A physiological model of the interaction between tissue bubbles and the formation of blood-borne bubbles under decompression

    International Nuclear Information System (INIS)

    Chappell, M A; Payne, S J

    2006-01-01

    Under decompression, bubbles can form in the human body, and these can be found both within the body tissues and the bloodstream. Mathematical models for the growth of both types of bubbles have previously been presented, but they have not been coupled together. This work thus explores the interaction between the growth of tissue and blood-borne bubbles under decompression, specifically looking at the extent to which they compete for the common resource of inert gas held in solution in the tissues. The influence of tissue bubbles is found to be significant for densities as low as 10 ml -1 for tissues which are poorly perfused. However, the effects of formation of bubbles in the blood are not found until the density of bubble production sites reaches 10 6 ml -1 . From comparison of the model predictions with experimental evidence for bubbles produced in animals and man under decompression, it is concluded that the density of tissue bubbles is likely to have a significant effect on the number of bubbles produced in the blood. However, the density of nucleation sites in the blood is unlikely to be sufficiently high in humans for the formation of bubbles in the blood to have a significant impact on the growth of the bubbles in the tissue

  5. Mechanics of gas-vapor bubbles

    NARCIS (Netherlands)

    Hao, Yue; Zhang, Yuhang; Prosperetti, Andrea

    2017-01-01

    Most bubbles contain a mixture of vapor and incondensible gases. While the limit cases of pure vapor and pure gas bubbles are well studied, much less is known about the more realistic case of a mixture. The bubble contents continuously change due to the combined effects of evaporation and

  6. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriëtte; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michaël A.; Spronk, Peter E.

    2012-01-01

    Objective: The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design: Prospective observational controlled study. Setting: Nonacademic university-affiliated

  7. A new veno-venous bypass type for ex-vivo liver resection in dogs.

    Science.gov (United States)

    Lei, Peng; Liu, Shi-Qi; Cui, Xiao-Hai; Lv, Yi; Zhao, Ge; Li, Jian-Hui

    2013-08-01

    Ex-vivo liver resection is a procedure in which the liver is completely removed, perfused and after bench surgery, the liver is autotransplanted to the original site. Ex-vivo liver resection is an important treatment for unresectable liver tumors. This surgical procedure requires long operation time, during which blood flow must be carefully maintained to avoid venous congestion. An effective veno-venous bypass (VVB) may meet this requirement. The present study was to test our new designed VVB device which comprised one heparinized polyvinylchloride tube and three magnetic rings. The efficacy of this device was tested in five dogs. A VVB was established in 6-10 minutes. There was no leakage during the procedure. Hemodynamics was stable at anhepatic phase, which indicated that the bypass was successful. This newly-developed VVB device maintained circulation stability during ex-vivo liver resection in our dog model and thus, this VVB device significantly shortened the operation time.

  8. Sonoluminescence and bubble fusion

    OpenAIRE

    Arakeri, Vijay H

    2003-01-01

    Sonoluminescence (SL), the phenomenon of light emission from nonlinear motion of a gas bubble, involves an extreme degree of energy focusing. The conditions within the bubble during the last stages of the nearly catastrophic implosion are thought to parallel the efforts aimed at developing inertial confinement fusion. A limited review on the topic of SL and its possible connection to bubble nuclear fusion is presented here. The emphasis is on looking for a link between the various forms o...

  9. Hydrogen peroxide ingestion associated with portal venous gas and treatment with hyperbaric oxygen: a case series and review of the literature.

    Science.gov (United States)

    French, Loren Keith; Horowitz, B Zane; McKeown, Nathanael J

    2010-07-01

    Ingestion of concentrated hydrogen peroxide (H(2)O(2)) has been associated with venous and arterial gas embolic events, hemorrhagic gastritis, gastrointestinal bleeding, shock, and death. Although H(2)O(2) is generally considered a benign ingestion in low concentrations, case reports have described serious toxicity following high concentration exposures. Hyperbaric oxygen (HBO) has been used with success in managing patients suffering from gas embolism with and without manifestations of ischemia. Poison center records were searched from July 1999 to January 2010 for patients with H(2)O(2) exposure and HBO treatment. Cases were reviewed for the concentration of H(2)O(2), symptoms, CT scan findings of portal gas embolism, HBO treatment, and outcome. RESULTS; Eleven cases of portal gas embolism were found. Ages ranged from 4 to 89 years. All but one ingestion was accidental in nature. In 10 cases 35% H(2)O(2) was ingested and in 1 case 12% H(2)O(2) was ingested. All abdominal CT scans demonstrated portal venous gas embolism in all cases. Hyperbaric treatment was successful in completely resolving all portal venous gas bubbles in nine patients (80%) and nearly resolving them in two others. Ten patients were able to be discharged home within 1 day, and one patient had a 3.5-day length of stay. HBO was successful in resolving portal venous gas embolism from accidental concentrated H(2)O(2) ingestions.

  10. Does cryotherapy improve skin circulation compared with compression and elevation in preventing venous leg ulcers?

    Science.gov (United States)

    Kelechi, Teresa J; Mueller, Martina; Madisetti, Mohan; Prentice, Margie A; Dooley, Mary J

    2017-08-01

    This trial compared skin blood flow, temperature and incidence of venous leg ulcers in patients with chronic venous disease using compression wraps and elevation pillows. Patients with CEAP C4 skin damage and C5 history of ulcers were randomly assigned to a cryotherapy intervention (n = 138) or placebo cuff control (n = 138) applied to the lower legs over 9 months. The time the ulcers healed prior to enrollment in the study for the cryotherapy group ranged from 1 to 2218 days (n = 8, median = 32 days); for the control group, the range was 24 to 489 days (n = 6, median = 390 days). There were no statistically significant blood flow changes measured in perfusion units with a laser Doppler flowmetre within or between the groups; mean difference between the groups was 0·62, P = 0·619. No differences were noted in skin temperature measured with an infrared thermometer within and between the groups; mean difference between the groups was -0·17°C, P = 0·540. Cryotherapy did not improve skin blood flow or temperature and did not show efficacy in preventing ulcers. However, at least 30% of intervention and 50% of control participants were anticipated to develop an ulcer during the study; only ∼7% occurred. These findings suggest that strict adherence to standard of care decreases the incidence of leg ulcers and remains a best practice for leg ulcer prevention. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  11. New mechanism for bubble nucleation: Classical transitions

    International Nuclear Information System (INIS)

    Easther, Richard; Giblin, John T. Jr; Hui Lam; Lim, Eugene A.

    2009-01-01

    Given a scalar field with metastable minima, bubbles nucleate quantum mechanically. When bubbles collide, energy stored in the bubble walls is converted into kinetic energy of the field. This kinetic energy can facilitate the classical nucleation of new bubbles in minima that lie below those of the 'parent' bubbles. This process is efficient and classical, and changes the dynamics and statistics of bubble formation in models with multiple vacua, relative to that derived from quantum tunneling.

  12. Leverage bubble

    Science.gov (United States)

    Yan, Wanfeng; Woodard, Ryan; Sornette, Didier

    2012-01-01

    Leverage is strongly related to liquidity in a market and lack of liquidity is considered a cause and/or consequence of the recent financial crisis. A repurchase agreement is a financial instrument where a security is sold simultaneously with an agreement to buy it back at a later date. Repurchase agreement (repo) market size is a very important element in calculating the overall leverage in a financial market. Therefore, studying the behavior of repo market size can help to understand a process that can contribute to the birth of a financial crisis. We hypothesize that herding behavior among large investors led to massive over-leveraging through the use of repos, resulting in a bubble (built up over the previous years) and subsequent crash in this market in early 2008. We use the Johansen-Ledoit-Sornette (JLS) model of rational expectation bubbles and behavioral finance to study the dynamics of the repo market that led to the crash. The JLS model qualifies a bubble by the presence of characteristic patterns in the price dynamics, called log-periodic power law (LPPL) behavior. We show that there was significant LPPL behavior in the market before that crash and that the predicted range of times predicted by the model for the end of the bubble is consistent with the observations.

  13. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriette; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michael A.; Spronk, Peter E.

    2012-01-01

    Objective:  The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design:  Prospective observational controlled study. Setting:  Nonacademic university-affiliated

  14. Armoring confined bubbles in concentrated colloidal suspensions

    Science.gov (United States)

    Yu, Yingxian; Khodaparast, Sepideh; Stone, Howard

    2016-11-01

    Encapsulation of a bubble with microparticles is known to significantly improve the stability of the bubble. This phenomenon has recently gained increasing attention due to its application in a variety of technologies such as foam stabilization, drug encapsulation and colloidosomes. Nevertheless, the production of such colloidal armored bubble with controlled size and particle coverage ratio is still a great challenge industrially. We study the coating process of a long air bubble by microparticles in a circular tube filled with a concentrated microparticles colloidal suspension. As the bubble proceeds in the suspension of particles, a monolayer of micro-particles forms on the interface of the bubble, which eventually results in a fully armored bubble. We investigate the phenomenon that triggers and controls the evolution of the particle accumulation on the bubble interface. Moreover, we examine the effects of the mean flow velocity, the size of the colloids and concentration of the suspension on the dynamics of the armored bubble. The results of this study can potentially be applied to production of particle-encapsulated bubbles, surface-cleaning techniques, and gas-assisted injection molding.

  15. Manipulating bubbles with secondary Bjerknes forces

    Energy Technology Data Exchange (ETDEWEB)

    Lanoy, Maxime [Institut Langevin, ESPCI ParisTech, CNRS (UMR 7587), PSL Research University, 1 rue Jussieu, 75005 Paris (France); Laboratoire Matière et Systèmes Complexes, Université Paris-Diderot, CNRS (UMR 7057), 10 rue Alice Domon et Léonie Duquet, 75013 Paris (France); Derec, Caroline; Leroy, Valentin [Laboratoire Matière et Systèmes Complexes, Université Paris-Diderot, CNRS (UMR 7057), 10 rue Alice Domon et Léonie Duquet, 75013 Paris (France); Tourin, Arnaud [Institut Langevin, ESPCI ParisTech, CNRS (UMR 7587), PSL Research University, 1 rue Jussieu, 75005 Paris (France)

    2015-11-23

    Gas bubbles in a sound field are submitted to a radiative force, known as the secondary Bjerknes force. We propose an original experimental setup that allows us to investigate in detail this force between two bubbles, as a function of the sonication frequency, as well as the bubbles radii and distance. We report the observation of both attractive and, more interestingly, repulsive Bjerknes force, when the two bubbles are driven in antiphase. Our experiments show the importance of taking multiple scatterings into account, which leads to a strong acoustic coupling of the bubbles when their radii are similar. Our setup demonstrates the accuracy of secondary Bjerknes forces for attracting or repealing a bubble, and could lead to new acoustic tools for noncontact manipulation in microfluidic devices.

  16. Manipulating bubbles with secondary Bjerknes forces

    International Nuclear Information System (INIS)

    Lanoy, Maxime; Derec, Caroline; Leroy, Valentin; Tourin, Arnaud

    2015-01-01

    Gas bubbles in a sound field are submitted to a radiative force, known as the secondary Bjerknes force. We propose an original experimental setup that allows us to investigate in detail this force between two bubbles, as a function of the sonication frequency, as well as the bubbles radii and distance. We report the observation of both attractive and, more interestingly, repulsive Bjerknes force, when the two bubbles are driven in antiphase. Our experiments show the importance of taking multiple scatterings into account, which leads to a strong acoustic coupling of the bubbles when their radii are similar. Our setup demonstrates the accuracy of secondary Bjerknes forces for attracting or repealing a bubble, and could lead to new acoustic tools for noncontact manipulation in microfluidic devices

  17. Nucleation in bubble chambers

    International Nuclear Information System (INIS)

    Harigel, G.G.

    1988-01-01

    Various sources and mechanisms for bubble formation in superheated liquids are discussed. Bubble chambers can be filled with a great variety of liquids, such as e.g. the cryogenic liquids hydrogen, deuterium, neon, neon/hydrogen mixtures, argon, nitrogen, argon/nitrogen mixtures, or the warm liquids propane and various Freon like Freon-13B1. The superheated state is normally achieved by a rapid movement of an expansion piston or membrane, but can also be produced by standing ultrasonic waves, shock waves, or putting liquids under tension. Bubble formation can be initiated by ionizing particles, by intense (laser) light, or on rough surfaces. The creation of embryonic bubbles is not completely understood, but the macroscopic growth and condensation can be calculated, allowing to estimate the dynamic heat load [fr

  18. Protocol for the realization of venous mapping by chronic venous insufficiency in lower limbs under sonographic guide

    International Nuclear Information System (INIS)

    Blanco Rojas, Diego Jose

    2013-01-01

    The current state of knowledge is reviewed with respect to the realization of lower limbs venous mapping. Venous mapping is obtained by the use of color and spectral Doppler ultrasound. Doppler ultrasound has provided a precise graphical representation of the superficial and deep venous systems. The performance of the venous mapping is considered essential for the correct handling of venous diseases. The anatomical and pathophysiological basic concepts are defined to realize the sonographic assessment of the veins of the lower limbs. The required technical aspects are revised for the realization of sonographic exploration of the patient with venous insufficiency. Sonographic findings are characterized to support the diagnostic of venous insufficiency of the lower limbs. The CEAP (clinical-etiologic-anatomic-pathophysiologic) classification is utilized to differentiate forms and degrees of severity of the disorder, and has allowed an interinstitutional comparison in clinical studies, the evaluation of treatment and monitoring of patients. A proposal is designed to perform reports that have served of guide surgical to vascular surgeons [es

  19. Distensibility and pressure-flow relationship of the pulmonary circulation. II. Multibranched model.

    Science.gov (United States)

    Bshouty, Z; Younes, M

    1990-04-01

    The contribution of distensibility and recruitment to the distinctive behavior of the pulmonary circulation is not known. To examine this question we developed a multibranched model in which an arterial vascular bed bifurcates sequentially up to 8 parallel channels that converge and reunite at the venous side to end in the left atrium. Eight resistors representing the capillary bed separate the arterial and venous beds. The elastic behavior of capillaries and extra-alveolar vessels was modeled after Fung and Sobin (Circ. Res. 30: 451-490, 1972) and Smith and Mitzner (J. Appl. Physiol. 48: 450-467, 1980), respectively. Forces acting on each component are modified and calculated individually, thus enabling the user to explore the effects of parallel and longitudinal heterogeneities in applied forces (e.g., gravity, vasomotor tone). Model predictions indicate that the contribution of distensibility to nonlinearities in the pressure-flow (P-F) and atrial-pulmonary arterial pressure (Pla-Ppa) relationships is substantial, whereas gravity-related recruitment contributes very little to these relationships. In addition, Pla-Ppa relationships, obtained at a constant flow, have no discriminating ability in identifying the presence or absence of a waterfall along the circulation. The P-F relationship is routinely shifted in a parallel fashion, within the physiological flow range, whenever extra forces (e.g., lung volume, tone) are applied uniformly at one or more branching levels, regardless of whether a waterfall is created. For a given applied force, the magnitude of parallel shift varies with proportion of the circulation subjected to the added force and with Pla.

  20. Human cerebral venous outflow pathway depends on posture and central venous pressure

    DEFF Research Database (Denmark)

    Gisolf, J; van Lieshout, J J; van Heusden, K

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture...... and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R(2) = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway...

  1. Spherical Solutions of an Underwater Explosion Bubble

    Directory of Open Access Journals (Sweden)

    Andrew B. Wardlaw

    1998-01-01

    Full Text Available The evolution of the 1D explosion bubble flow field out to the first bubble minimum is examined in detail using four different models. The most detailed is based on the Euler equations and accounts for the internal bubble fluid motion, while the simplest links a potential water solution to a stationary, Isentropic bubble model. Comparison of the different models with experimental data provides insight into the influence of compressibility and internal bubble dynamics on the behavior of the explosion bubble.

  2. Helium bubble bursting in tungsten

    International Nuclear Information System (INIS)

    Sefta, Faiza; Juslin, Niklas; Wirth, Brian D.

    2013-01-01

    Molecular dynamics simulations have been used to systematically study the pressure evolution and bursting behavior of sub-surface helium bubbles and the resulting tungsten surface morphology. This study specifically investigates how bubble shape and size, temperature, tungsten surface orientation, and ligament thickness above the bubble influence bubble stability and surface evolution. The tungsten surface is roughened by a combination of adatom “islands,” craters, and pinholes. The present study provides insight into the mechanisms and conditions leading to various tungsten topology changes, which we believe are the initial stages of surface evolution leading to the formation of nanoscale fuzz

  3. Colorectal cancer with venous tumor thrombosis

    OpenAIRE

    Kensuke Otani; Soichiro Ishihara; Keisuke Hata; Koji Murono; Kazuhito Sasaki; Koji Yasuda; Takeshi Nishikawa; Toshiaki Tanaka; Tomomichi Kiyomatsu; Kazushige Kawai; Hiroaki Nozawa; Hironori Yamaguchi; Toshiaki Watanabe

    2018-01-01

    Summary: Colorectal cancer is seldom accompanied by venous tumor thrombosis, and little is known about the features of venous tumor thrombosis in colorectal cancer. However, some reports show that colorectal cancer patients can develop venous tumor thrombosis and warn clinicians not to overlook this complication. In this report, we perform a review of 43 previously reported cases and investigate the characteristics of colorectal cancer accompanied by venous tumor thrombosis. The histological ...

  4. Review on fiber morphology obtained by bubble electrospinning and blown bubble spinning

    Directory of Open Access Journals (Sweden)

    He Ji-Huan

    2012-01-01

    Full Text Available Here we show an intriguing phenomenon in the bubble electrospinning process that the ruptured film might be stripped upwards by an electronic force to form a very thin and long plate-like strip, which might been received in the metal receiver as discontinuous backbone-like wrinkled materials, rather than smooth nano-fibers or microspheres. The processes are called the bubble electrospinning. The electronic force can be replaced by a blowing air, and the process is called as the blown bubble spinning. We demonstrate that the size and thickness of the ruptured film are the crucial parameters that are necessary to understand the various observations including beads and nanoporous materials. We identify the conditions required for a ruptured film to form discontinuous structure, and a critical width of the ruptured film to form a cylindrical fiber, above which a long and thin plate-like strip might be obtained, and a criterion for oscillatory jet diameter, which leads to bead morphology of the obtained fibers. The space of the adjacent beads depends on the fiber size. We anticipate our assay to be a starting point for more sophisticated study of the bubble electrospinning and the blown bubble spinning and for mass-production of both nanofibers and nanoscale discontinuous materials.

  5. A Novel Technique Using a Protection Filter During Fibrin Sheath Removal for Implanted Venous Access Device Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Sotiriadis, Charalampos; Hajdu, Steven David [University Hospital of Lausanne, Cardiothoracic and Vascular Unit, Department of Radiology (Switzerland); Degrauwe, Sophie [University Hospital of Lausanne, Department of Cardiology (Switzerland); Barras, Heloise; Qanadli, Salah Dine, E-mail: salah.qanadli@chuv.ch [University Hospital of Lausanne, Cardiothoracic and Vascular Unit, Department of Radiology (Switzerland)

    2016-08-15

    With the increased use of implanted venous access devices (IVADs) for continuous long-term venous access, several techniques such as percutaneous endovascular fibrin sheath removal, have been described, to maintain catheter function. Most standard techniques do not capture the stripped fibrin sheath, which is subsequently released in the pulmonary circulation and may lead to symptomatic pulmonary embolism. The presented case describes an endovascular technique which includes stripping, capture, and removal of fibrin sheath using a novel filter device. A 64-year-old woman presented with IVAD dysfunction. Stripping was performed using a co-axial snare to the filter to capture the fibrin sheath. The captured fragment was subsequently removed for visual and pathological verification. No immediate complication was observed and the patient was discharged the day of the procedure.

  6. Influence of drag closures and inlet conditions on bubble dynamics and flow behavior inside a bubble column

    Directory of Open Access Journals (Sweden)

    Amjad Asad

    2017-01-01

    Full Text Available In this paper, the hydrodynamics of a bubble column is investigated numerically using the discrete bubble model, which tracks the dispersed bubbles individually in a liquid column. The discrete bubble model is combined with the volume of fluid approach to account for a proper free surface boundary condition at the liquid–gas interface. This improves describing the backflow region, which takes place close to the wall region. The numerical simulation is conducted by means of the open source computational fluid dynamics library OpenFOAM®. In order to validate the numerical model, experimental results of a bubble column are used. The numerical prediction shows an overall good agreement compared to the experimental data. The effect of injection conditions and the influence of the drag closures on bubble dynamics are investigated in the current paper. Here, the significant effect of injection boundary conditions on bubble dynamics and flow velocity in the studied cavity is revealed. Moreover, the impact of the choice of the drag closure on the liquid velocity field and on bubble behavior is indicated by comparing three drag closures derived from former studies.

  7. Determination of size distribution of bubbles in a bubbly column two phase flows by ultrasound and neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Baroni, Douglas B.; Lamy, Carlos A.; Bittencourt, Marcelo S.Q.; Pereira, Claudio M.N.A., E-mail: douglasbaroni@ien.gov.b, E-mail: lamy@ien.gov.b, E-mail: bittenc@ien.gov.b, E-mail: cmnap@ien.gov.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Cunha Filho, Jurandyr S. [Escola Tecnica Estadual Visconde de Maua (ETEVM/RJ), Rio de Janeiro, RJ (Brazil); Motta, Mauricio S., E-mail: mmotta@cefet-rj.b [Centro Federal de Educacao Tecnologica Celso Suckow da Fonseca (CEFET/RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    The development of advanced nuclear reactor conceptions depends largely on the amount of available data to the designer. Non invasive ultrasonic techniques can contribute to the evaluation of gas-liquid two-phase regimes in the nuclear thermo-hydraulic circuits. A key-point for success of those techniques is the interpretation of the ultrasonic signal. In this work, a methodology based in artificial neural networks (ANN) is proposed to predict size distribution of bubbles in a bubbly flow. To accomplish that, an air feed system control was used to obtain specific bubbly flows in an experimental system utilizing a Plexiglas vertical bubbly column. Four different size distribution of bubbles were generated. The bubbles were photographed and measured. To evaluate the different size distribution of bubbles it was used the ultrasonic reflected echo on the opposite wall of the column. Then, an ANN has been developed for predicting size distribution of bubbles by using the frequency spectra of the ultrasonic signal as input. A trained artificial neural network using ultrasonic signal in the frequency domain can evaluate with a good precision the size distribution of bubbles generated in this system. (author)

  8. Determination of size distribution of bubbles in a bubbly column two phase flows by ultrasound and neural networks

    International Nuclear Information System (INIS)

    Baroni, Douglas B.; Lamy, Carlos A.; Bittencourt, Marcelo S.Q.; Pereira, Claudio M.N.A.; Cunha Filho, Jurandyr S.; Motta, Mauricio S.

    2011-01-01

    The development of advanced nuclear reactor conceptions depends largely on the amount of available data to the designer. Non invasive ultrasonic techniques can contribute to the evaluation of gas-liquid two-phase regimes in the nuclear thermo-hydraulic circuits. A key-point for success of those techniques is the interpretation of the ultrasonic signal. In this work, a methodology based in artificial neural networks (ANN) is proposed to predict size distribution of bubbles in a bubbly flow. To accomplish that, an air feed system control was used to obtain specific bubbly flows in an experimental system utilizing a Plexiglas vertical bubbly column. Four different size distribution of bubbles were generated. The bubbles were photographed and measured. To evaluate the different size distribution of bubbles it was used the ultrasonic reflected echo on the opposite wall of the column. Then, an ANN has been developed for predicting size distribution of bubbles by using the frequency spectra of the ultrasonic signal as input. A trained artificial neural network using ultrasonic signal in the frequency domain can evaluate with a good precision the size distribution of bubbles generated in this system. (author)

  9. Vasopressin and nitroglycerin decrease portal and hepatic venous pressure and hepato-splanchnic blood flow.

    Science.gov (United States)

    Wisén, E; Svennerholm, K; Bown, L S; Houltz, E; Rizell, M; Lundin, S; Ricksten, S-E

    2018-03-26

    Various methods are used to reduce venous blood pressure in the hepato-splanchnic circulation, and hence minimise blood loss during liver surgery. Previous studies show that combination of vasopressin and nitroglycerin reduces portal pressure and flow in patients with portal hypertension, and in this study we investigated this combination in patients with normal portal pressure. In all, 13 patients were studied. Measurements were made twice to confirm baseline (C1 and BL), during vasopressin infusion 4.8 U/h (V), and during vasopressin infusion combined with nitroglycerin infusion (V + N). Portal venous pressure (PVP), hepatic venous pressure (HVP), central haemodynamics and arterial and venous blood gases were obtained at each measuring point, and portal (splanchnic) and hepato-splanchnic blood flow changes were calculated. Vasopressin alone did not affect PVP, whereas HVP increased slightly. In combination with nitroglycerin, PVP decreased from 10.1 ± 1.6 to 8.9 ± 1.3 mmHg (P HVP decreased from 7.9 ± 1.9 to 6.2 ± 1.3 mmHg (P = 0.001). Vasopressin reduced portal blood flow by 47 ± 19% and hepatic venous flow by 11 ± 18%, respectively. Addition of nitroglycerin further reduced portal- and hepatic flow by 55 ± 13% and 30 ± 13%, respectively. Vasopressin alone had minor effects on central haemodynamics, whereas addition of nitroglycerin reduced cardiac index (3.2 ± 0.7 to 2.7 ± 0.5; P < 0.0001). The arterial-portal vein lactate gradient was unaffected. The combination of vasopressin and nitroglycerin decreases portal pressure and hepato-splanchnic blood flow, and could be a potential treatment to reduce bleeding in liver resection surgery. © 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. Effects of additional inertia force on bubble breakup

    International Nuclear Information System (INIS)

    Pan Liangming; Zhang Wenzhi; Chen Deqi; Xu Jianhui; Xu Jianjun; Huang Yanping

    2011-01-01

    Through VOF two-phase flow model, the single bubble deformation and breakup in a vertical narrow channel is numerically investigated in the study based on the force balance at the process of bubble breakup. The effect of surface tension force, the additional inertia force and bubble initial shape on bubble breakup are analyzed according to the velocity variation at the break-up point and the minimum necking size when the bubble is breaking up. It is found that the surface tension force, the additional inertia force and the bubble initial shape have significant effects on the bubble breakup through the fluid injection toward to the bubble, which finally induces the onset of bubble breakup. (authors)

  11. Observing and understanding arterial and venous circulation differences in a physiology laboratory activity.

    Science.gov (United States)

    Altermann, Caroline; Gonçalves, Rithiele; Lara, Marcus Vinícius S; Neves, Ben-Hur S; Mello-Carpes, Pâmela B

    2015-12-01

    The purpose of the present article is to describe three simple practical experiments that aim to observe and discuss the anatomic and physiological functions and differences between arteries and veins as well as the alterations observed in skin blood flow in different situations. For this activity, students were divided in small groups. In each group, a volunteer is recruited for each experiment. The experiments only require a sphygmomanometer, rubber bands, and a clock and allow students to develop a hypothesis to explain the different responses to the interruption of arterial and venous blood flow. At the end, students prepare a short report, and the results are discussed. This activity allows students to perceive the presence of physiology in their daily lives and helps them to understand the concepts related to the cardiovascular system and hemodynamics. Copyright © 2015 The American Physiological Society.

  12. Exercise increases circulating GDF15 in humans

    Directory of Open Access Journals (Sweden)

    Maximilian Kleinert

    2018-03-01

    Full Text Available Objective: The growth differentiation factor 15 (GDF15 is a stress-sensitive circulating factor that regulates systemic energy balance. Since exercise is a transient physiological stress that has pleiotropic effects on whole-body energy metabolism, we herein explored the effect of exercise on a circulating GDF15 levels and b GDF15 release from skeletal muscle in humans. Methods: Seven healthy males either rested or exercised at 67% of their VO2max for 1 h and blood was sampled from the femoral artery and femoral vein before, during, and after exercise. Plasma GDF15 concentrations were determined in these samples. Results: Plasma GDF15 levels increased 34% with exercise (p < 0.001 and further increased to 64% above resting values at 120 min (p < 0.001 after the cessation of exercise. There was no difference between the arterial and venous GDF15 concentration before, during, and after exercise. During a resting control trial, GDF15 levels measured in the same subjects were unaltered. Conclusions: Vigorous submaximal exercise increases circulating GDF15 levels in humans, but skeletal muscle tissue does not appear to be the source. Keywords: Skeletal muscle, Growth differentiation factor 15, Recovery, Physical activity

  13. Significance of venous anastomosis in fingertip replantation.

    Science.gov (United States)

    Hattori, Yasunori; Doi, Kazuteru; Ikeda, Keisuke; Abe, Yukio; Dhawan, Vikas

    2003-03-01

    Adequate venous outflow is the most important factor for successful fingertip replantation. The authors have attempted venous anastomosis in all cases of fingertip replantation to overcome postoperative congestion. In this article, the significance of venous repair for fingertip replantation is described from the authors' results of 64 complete fingertip amputations in 55 consecutive patients, which were replanted from January of 1996 to June of 2001. The overall survival rate was 86 percent. Of the 44 replantations in zone I, 37 survived, and the success rate was 84 percent. Of the 20 replantations in zone II, 18 survived, and the success rate was 90 percent. Venous anastomosis was attempted in all cases, but it was possible in 39 zone I and in all zone II replantations. For arterial repair, vein grafts were necessary in 17 of the 44 zone I and in one of the 20 zone II replantations; for venous repair, they were necessary in six zone I replantations and one zone II replantation. Postoperative vascular complications occurred in 15 replantations. There were five cases of arterial thrombosis and 10 cases of venous congestion. Venous congestion occurred in nine zone I and one zone II replantations. In five of these 10 replantations, venous anastomosis was not possible. In another five replantations, venous outflow was established at the time of surgery, but occlusion occurred subsequently. Except for the five failures resulting from arterial thrombosis, successful venous repair was possible in 49 of 59 replantations (83 percent). Despite the demand for skillful microsurgical technique and longer operation time, the authors' results using venous anastomosis in successful fingertip replantations are encouraging. By performing venous anastomosis, external bleeding can be avoided and a higher survival rate can be achieved. Venous anastomosis for fingertip replantation is a reliable and worthwhile procedure.

  14. [Risk factors for the development of venous insufficiency of the lower limbs during pregnancy--part 1].

    Science.gov (United States)

    Ropacka-Lesiak, Mariola; Kasperczak, Jarosław; Breborowicz, Grzegorz H

    2012-12-01

    The venous system alters its function in pregnancy--the changes are both functional and structural. It becomes particularly vulnerable to the development of venous thrombosis and related complications. These adverse factors acting on the veins in pregnancy include: an increase in circulating blood volume, expansion of the uterus, weight gain, reduced physical activity hormonal changes. The changes in the plasma have a significant impact on the venous system. In pregnancy an increased level of fibrinogen and coagulation factors VII, VIII, IX and X, and von Willenbrand factor can be observed. Smooth muscle relaxation and relaxation of collagen fibers are caused by progesterone and estrogen, and it may result in the development of varicose veins, venous thrombosis and venous insufficiency The relationships between the hormones and the muscle pump efficiency has not been proven as yet. Estrogens cause an increase in the synthesis of coagulation proteins and it may result in the high risk of venous thrombosis and its consequences. Progesterone inhibits smooth muscle contraction, while estrogens cause relaxation and loosening of the bonds between the collagen fibers. The increase in the level of progesterone is of particular importance. It has a relaxing effect on the muscle, resulting in disorders of the vein shrinkage, affecting the increase of their capacity and valvular insufficiency, and valvular edges are not in contact with each other due to the vasodilatation. Estrogens have a similar effect, and additionally it may also cause an impairment in the collagen fibers connection and synthesis. This can result in the formation of telanglectasia without venous hypertension. Estrogens may also affect the synthesis of prostaglandins and nitric oxide. Estradiol inhibits vascular smooth muscle cell proliferation and stimulates cell migration and secretion of matrix proteins, as well as regeneration of the damaged vessels. Estrogen inhibits the production of cytokines

  15. FEASTING BLACK HOLE BLOWS BUBBLES

    Science.gov (United States)

    2002-01-01

    A monstrous black hole's rude table manners include blowing huge bubbles of hot gas into space. At least, that's the gustatory practice followed by the supermassive black hole residing in the hub of the nearby galaxy NGC 4438. Known as a peculiar galaxy because of its unusual shape, NGC 4438 is in the Virgo Cluster, 50 million light-years from Earth. These NASA Hubble Space Telescope images of the galaxy's central region clearly show one of the bubbles rising from a dark band of dust. The other bubble, emanating from below the dust band, is barely visible, appearing as dim red blobs in the close-up picture of the galaxy's hub (the colorful picture at right). The background image represents a wider view of the galaxy, with the central region defined by the white box. These extremely hot bubbles are caused by the black hole's voracious eating habits. The eating machine is engorging itself with a banquet of material swirling around it in an accretion disk (the white region below the bright bubble). Some of this material is spewed from the disk in opposite directions. Acting like high-powered garden hoses, these twin jets of matter sweep out material in their paths. The jets eventually slam into a wall of dense, slow-moving gas, which is traveling at less than 223,000 mph (360,000 kph). The collision produces the glowing material. The bubbles will continue to expand and will eventually dissipate. Compared with the life of the galaxy, this bubble-blowing phase is a short-lived event. The bubble is much brighter on one side of the galaxy's center because the jet smashed into a denser amount of gas. The brighter bubble is 800 light-years tall and 800 light-years across. The observations are being presented June 5 at the American Astronomical Society meeting in Rochester, N.Y. Both pictures were taken March 24, 1999 with the Wide Field and Planetary Camera 2. False colors were used to enhance the details of the bubbles. The red regions in the picture denote the hot gas

  16. Bubbles in the self-accelerating universe

    International Nuclear Information System (INIS)

    Izumi, Keisuke; Tanaka, Takahiro; Koyama, Kazuya; Pujolas, Oriol

    2007-01-01

    We revisit the issue of the stability in the Dvali-Gabadadze-Porrati model by considering the nucleation of bubbles of the conventional branch within the self-accelerating branch. We construct an instanton describing this process in the thin wall approximation. On one side of the bubble wall, the bulk consists of the exterior of the brane, while on the other side it is the interior. The solution requires the presence of a 2-brane (the bubble wall) which induces the transition. However, we show that this instanton cannot be realized as the thin wall limit of any smooth solution. Once the bubble thickness is resolved, the equations of motion do not allow O(4) symmetric solutions joining the two branches. We conclude that the thin wall instanton is unphysical, and that one cannot have processes connecting the two branches, unless negative tension bubble walls are introduced. This also suggests that the self-accelerating branch does not decay into the conventional branch nucleating bubbles. We comment on other kinds of bubbles that could interpolate between the two branches

  17. Slowing down bubbles with sound

    Science.gov (United States)

    Poulain, Cedric; Dangla, Remie; Guinard, Marion

    2009-11-01

    We present experimental evidence that a bubble moving in a fluid in which a well-chosen acoustic noise is superimposed can be significantly slowed down even for moderate acoustic pressure. Through mean velocity measurements, we show that a condition for this effect to occur is for the acoustic noise spectrum to match or overlap the bubble's fundamental resonant mode. We render the bubble's oscillations and translational movements using high speed video. We show that radial oscillations (Rayleigh-Plesset type) have no effect on the mean velocity, while above a critical pressure, a parametric type instability (Faraday waves) is triggered and gives rise to nonlinear surface oscillations. We evidence that these surface waves are subharmonic and responsible for the bubble's drag increase. When the acoustic intensity is increased, Faraday modes interact and the strongly nonlinear oscillations behave randomly, leading to a random behavior of the bubble's trajectory and consequently to a higher slow down. Our observations may suggest new strategies for bubbly flow control, or two-phase microfluidic devices. It might also be applicable to other elastic objects, such as globules, cells or vesicles, for medical applications such as elasticity-based sorting.

  18. When Will Occur the Crude Oil Bubbles?

    International Nuclear Information System (INIS)

    Su, Chi-Wei; Li, Zheng-Zheng; Chang, Hsu-Ling; Lobonţ, Oana-Ramona

    2017-01-01

    In this paper, we apply a recursive unit root test to investigate whether there exist multiple bubbles in crude oil price. The method is best suited for a practical implementation of a time series and delivers a consistent date-stamping strategy for the origination and termination of multiple bubbles. The empirical result indicates that there exist six bubbles during 1986–2016 when the oil price deviate from its intrinsic value based on market fundamentals. Specifically, oil price contains the fundamentals and bubble components. The dates of the bubbles correspond to specific events in the politics and financial markets. The authorities should actively fight speculative bubbles or just observe their evolutions and speculation activities may decrease, which is favour of the stabilisation of the staple commodities including crude oil price. These findings have important economic and policy implications to recognise the cause of bubbles and take corresponding measures to reduce the impact on the real economy cause of the fluctuation of crude oil price. - Highlights: • Investigate multiple bubbles in crude oil price. • Indicate six bubbles deviate from its intrinsic value based on market fundamentals. • The bubbles correspond to specific events in the politics and financial markets. • Reduce the impact on the real economy cause of the fluctuation of crude oil price.

  19. Venous abnormalities demonstrated by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Tsukune, Y; Ashida, H; Tokuda, M; Oyama, Y [St. Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-05-01

    CT is capable of demonstrating various venous changes. However, little have been described on this subject in the literature. Examples of various venous abnormalities such as obstructed jugular vein, superior and inferior vena cava (IVC), tumor invasion of IVC and renal vein and venous changes in portal hypertension were presented. It was stressed that noninvasive CT is a good tool in diagnosis of some of venous changes and may be able to eliminate angiography in such cases.

  20. New evidence on the first financial bubble

    NARCIS (Netherlands)

    Frehen, R.G.P.; Goetzmann, W.; Rouwenhorst, K.G.

    2013-01-01

    The Mississippi Bubble, South Sea Bubble and the Dutch Windhandel of 1720 together represent the world's first global financial bubble. We hand-collect cross-sectional price data and investor account data from 1720 to test theories about market bubbles. Our tests suggest that innovation was a key

  1. Pinch-off Scaling Law of Soap Bubbles

    Science.gov (United States)

    Davidson, John; Ryu, Sangjin

    2014-11-01

    Three common interfacial phenomena that occur daily are liquid drops in gas, gas bubbles in liquid and thin-film bubbles. One aspect that has been studied for these phenomena is the formation or pinch-off of the drop/bubble from the liquid/gas threads. In contrast to the formation of liquid drops in gas and gas bubbles in liquid, thin-film bubble pinch-off has not been well documented. Having thin-film interfaces may alter the pinch-off process due to the limiting factor of the film thickness. We observed the pinch-off of one common thin-film bubble, soap bubbles, in order to characterize its pinch-off behavior. We achieved this by constructing an experimental model replicating the process of a human producing soap bubbles. Using high-speed videography and image processing, we determined that the minimal neck radius scaled with the time left till pinch-off, and that the scaling law exponent was 2/3, similar to that of liquid drops in gas.

  2. Bubbles with shock waves and ultrasound: a review.

    Science.gov (United States)

    Ohl, Siew-Wan; Klaseboer, Evert; Khoo, Boo Cheong

    2015-10-06

    The study of the interaction of bubbles with shock waves and ultrasound is sometimes termed 'acoustic cavitation'. It is of importance in many biomedical applications where sound waves are applied. The use of shock waves and ultrasound in medical treatments is appealing because of their non-invasiveness. In this review, we present a variety of acoustics-bubble interactions, with a focus on shock wave-bubble interaction and bubble cloud phenomena. The dynamics of a single spherically oscillating bubble is rather well understood. However, when there is a nearby surface, the bubble often collapses non-spherically with a high-speed jet. The direction of the jet depends on the 'resistance' of the boundary: the bubble jets towards a rigid boundary, splits up near an elastic boundary, and jets away from a free surface. The presence of a shock wave complicates the bubble dynamics further. We shall discuss both experimental studies using high-speed photography and numerical simulations involving shock wave-bubble interaction. In biomedical applications, instead of a single bubble, often clouds of bubbles appear (consisting of many individual bubbles). The dynamics of such a bubble cloud is even more complex. We shall show some of the phenomena observed in a high-intensity focused ultrasound (HIFU) field. The nonlinear nature of the sound field and the complex inter-bubble interaction in a cloud present challenges to a comprehensive understanding of the physics of the bubble cloud in HIFU. We conclude the article with some comments on the challenges ahead.

  3. Single DNA denaturation and bubble dynamics

    International Nuclear Information System (INIS)

    Metzler, Ralf; Ambjoernsson, Tobias; Hanke, Andreas; Fogedby, Hans C

    2009-01-01

    While the Watson-Crick double-strand is the thermodynamically stable state of DNA in a wide range of temperature and salt conditions, even at physiological conditions local denaturation bubbles may open up spontaneously due to thermal activation. By raising the ambient temperature, titration, or by external forces in single molecule setups bubbles proliferate until full denaturation of the DNA occurs. Based on the Poland-Scheraga model we investigate both the equilibrium transition of DNA denaturation and the dynamics of the denaturation bubbles with respect to recent single DNA chain experiments for situations below, at, and above the denaturation transition. We also propose a new single molecule setup based on DNA constructs with two bubble zones to measure the bubble coalescence and extract the physical parameters relevant to DNA breathing. Finally we consider the interplay between denaturation bubbles and selectively single-stranded DNA binding proteins.

  4. A bubble column evaporator with basic flat-plate condenser for brackish and seawater desalination.

    Science.gov (United States)

    Schmack, Mario; Ho, Goen; Anda, Martin

    2016-01-01

    This paper describes the development and experimental evaluation of a novel bubble column-based humidification-dehumidification system, for small-scale desalination of saline groundwater or seawater in remote regions. A bubble evaporator prototype was built and matched with a simple flat-plate type condenser for concept assessment. Consistent bubble evaporation rates of between 80 and 88 ml per hour were demonstrated. Particular focus was on the performance of the simple condenser prototype, manufactured from rectangular polyvinylchlorid plastic pipe and copper sheet, a material with a high thermal conductivity that quickly allows for conduction of the heat energy. Under laboratory conditions, a long narrow condenser model of 1500 mm length and 100 mm width achieved condensate recovery rates of around 73%, without the need for external cooling. The condenser prototype was assessed under a range of different physical conditions, that is, external water cooling, partial insulation and aspects of air circulation, via implementing an internal honeycomb screen structure. Estimated by extrapolation, an up-scaled bubble desalination system with a 1 m2 condenser may produce around 19 l of distilled water per day. Sodium chloride salt removal was found to be highly effective with condensate salt concentrations between 70 and 135 µS. Based on findings and with the intent to reduce material cost of the system, a shorter condenser length of 750 mm for the non-cooled (passive) condenser and of 500 mm for the water-cooled condenser was considered to be equally efficient as the experimentally evaluated prototype of 1500 mm length.

  5. Altered Venous Function during Long-Duration Spaceflights

    Directory of Open Access Journals (Sweden)

    Jacques-Olivier Fortrat

    2017-09-01

    Full Text Available Aims: Venous adaptation to microgravity, associated with cardiovascular deconditioning, may contribute to orthostatic intolerance following spaceflight. The aim of this study was to analyze the main parameters of venous hemodynamics with long-duration spaceflight.Methods: Venous plethysmography was performed on 24 cosmonauts before, during, and after spaceflights aboard the International Space Station. Venous plethysmography assessed venous filling and emptying functions as well as microvascular filtration, in response to different levels of venous occlusion pressure. Calf volume was assessed using calf circumference measurements.Results: Calf volume decreased during spaceflight from 2.3 ± 0.3 to 1.7 ± 0.2 L (p < 0.001, and recovered after it (2.3 ± 0.3 L. Venous compliance, determined as the relationship between occlusion pressure and the change in venous volume, increased during spaceflight from 0.090 ± 0.005 to 0.120 ± 0.007 (p < 0.01 and recovered 8 days after landing (0.071 ± 0.005, arbitrary units. The index of venous emptying rate decreased during spaceflight from −0.004 ± 0.022 to −0.212 ± 0.033 (p < 0.001, arbitrary units. The index of vascular microfiltration increased during spaceflight from 6.1 ± 1.8 to 10.6 ± 7.9 (p < 0.05, arbitrary units.Conclusion: This study demonstrated that overall venous function is changed during spaceflight. In future, venous function should be considered when developing countermeasures to prevent cardiovascular deconditioning and orthostatic intolerance with long-duration spaceflight.

  6. Mesoporous hollow spheres from soap bubbling.

    Science.gov (United States)

    Yu, Xianglin; Liang, Fuxin; Liu, Jiguang; Lu, Yunfeng; Yang, Zhenzhong

    2012-02-01

    The smaller and more stable bubbles can be generated from the large parent bubbles by rupture. In the presence of a bubble blowing agent, hollow spheres can be prepared by bubbling a silica sol. Herein, the trapped gas inside the bubble acts as a template. When the porogen, i.e., other surfactant, is introduced, a mesostructured shell forms by the co-assembly with the silica sol during sol-gel process. Morphological evolution emphasizes the prerequisite of an intermediate interior gas flow rate and high exterior gas flow rate for hollow spheres. The method is valid for many compositions from inorganic, polymer to their composites. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Rotating bubble membrane radiator

    Science.gov (United States)

    Webb, Brent J.; Coomes, Edmund P.

    1988-12-06

    A heat radiator useful for expelling waste heat from a power generating system aboard a space vehicle is disclosed. Liquid to be cooled is passed to the interior of a rotating bubble membrane radiator, where it is sprayed into the interior of the bubble. Liquid impacting upon the interior surface of the bubble is cooled and the heat radiated from the outer surface of the membrane. Cooled liquid is collected by the action of centrifical force about the equator of the rotating membrane and returned to the power system. Details regarding a complete space power system employing the radiator are given.

  8. Combined oral contraceptives: venous thrombosis.

    Science.gov (United States)

    de Bastos, Marcos; Stegeman, Bernardine H; Rosendaal, Frits R; Van Hylckama Vlieg, Astrid; Helmerhorst, Frans M; Stijnen, Theo; Dekkers, Olaf M

    2014-03-03

    Combined oral contraceptive (COC) use has been associated with venous thrombosis (VT) (i.e., deep venous thrombosis and pulmonary embolism). The VT risk has been evaluated for many estrogen doses and progestagen types contained in COC but no comprehensive comparison involving commonly used COC is available. To provide a comprehensive overview of the risk of venous thrombosis in women using different combined oral contraceptives. Electronic databases (Pubmed, Embase, Web of Science, Cochrane, CINAHL, Academic Search Premier and ScienceDirect) were searched in 22 April 2013 for eligible studies, without language restrictions. We selected studies including healthy women taking COC with VT as outcome. The primary outcome of interest was a fatal or non-fatal first event of venous thrombosis with the main focus on deep venous thrombosis or pulmonary embolism. Publications with at least 10 events in total were eligible. The network meta-analysis was performed using an extension of frequentist random effects models for mixed multiple treatment comparisons. Unadjusted relative risks with 95% confidence intervals were reported.Two independent reviewers extracted data from selected studies. 3110 publications were retrieved through a search strategy; 25 publications reporting on 26 studies were included. Incidence of venous thrombosis in non-users from two included cohorts was 0.19 and 0.37 per 1 000 person years, in line with previously reported incidences of 0,16 per 1 000 person years. Use of combined oral contraceptives increased the risk of venous thrombosis compared with non-use (relative risk 3.5, 95% confidence interval 2.9 to 4.3). The relative risk of venous thrombosis for combined oral contraceptives with 30-35 μg ethinylestradiol and gestodene, desogestrel, cyproterone acetate, or drospirenone were similar and about 50-80% higher than for combined oral contraceptives with levonorgestrel. A dose related effect of ethinylestradiol was observed for gestodene

  9. Electroweak bubble wall speed limit

    Energy Technology Data Exchange (ETDEWEB)

    Bödeker, Dietrich [Fakultät für Physik, Universität Bielefeld, 33501 Bielefeld (Germany); Moore, Guy D., E-mail: bodeker@physik.uni-bielefeld.de, E-mail: guymoore@ikp.physik.tu-darmstadt.de [Institut für Kernphysik, Technische Universität Darmstadt, Schlossgartenstraße 2, 64289 Darmstadt (Germany)

    2017-05-01

    In extensions of the Standard Model with extra scalars, the electroweak phase transition can be very strong, and the bubble walls can be highly relativistic. We revisit our previous argument that electroweak bubble walls can 'run away,' that is, achieve extreme ultrarelativistic velocities γ ∼ 10{sup 14}. We show that, when particles cross the bubble wall, they can emit transition radiation. Wall-frame soft processes, though suppressed by a power of the coupling α, have a significance enhanced by the γ-factor of the wall, limiting wall velocities to γ ∼ 1/α. Though the bubble walls can move at almost the speed of light, they carry an infinitesimal share of the plasma's energy.

  10. Venous chest anatomy: clinical implications

    International Nuclear Information System (INIS)

    Chasen, M.H.; Charnsangavej, C.

    1998-01-01

    This article provides a practical approach to the clinical implications and importance of understanding the collateral venous anatomy of the thorax. Routine radiography, conventional venography, computed tomography (CT), and magnetic resonance (MR) imaging studies provide correlative anatomic models for the demonstration of how interconnecting collateral vascular networks within the thorax maintain venous stability at all times. Five major systems comprise the collateral venous network of the thorax ( Fig. 1 ). These include the paravertebral, azygos-hemiazygos, internal mammary, lateral thoracic, and anterior jugular venous systems (AJVS). The five systems are presented in the following sequence: (a) a brief introduction to the importance of catheter position and malposition in understanding access to the thoracic venous system, (b) the anatomy of the azygos-hemiazygos systems and their relationship with the paravertebral plexus, (c) the importance of the AJVS, (d) 'loop' concepts interconnecting the internal mammary and azygos-hemiazygos systems by means of the lateral thoracic and intercostal veins, and (e) the interconnecting venous networks on the thoracic side of the thoracoabdominal junction. Certain aspects of the venous anatomy of the thorax will not be discussed in this chapter and include (a) the intra-abdominal anastomoses between the superior and inferior vena cavae (IVC) via the internal mammary, lateral thoracic, and azygos-hemiazygos systems (beyond the scope of this article), (b) potential collateral vessels involving vertebral, parascapular, thyroidal, thymic, and other smaller veins that might anastomose with the major systems, and (c) anatomic variants and pitfalls that may mimic pathologic conditions (space limitations). (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  11. Sonographic detection of portal venous gas

    International Nuclear Information System (INIS)

    Lee, Wang Yul; Lee, S. K.; Cho, O. K.

    1989-01-01

    Portal venous gas suggests underlying bowel disease such as strangulating intestinal obstruction and its demonstration carries with it an important implications with respect to patient management. Radiography has been the gold standard for the detection of portal venous gas. We have experienced two cases of portal venous gas diagnosed by ultrasound. Sonographic findings were floating echoes in the main portal vein and highly echogenic linear or patchy echoes within the hepatic parenchyma. Simple abdominal films of those cases failed to demonstrate gas in the portal venous system

  12. Venous pump of the calf: a study of venous and muscular pressures.

    Science.gov (United States)

    Alimi, Y S; Barthelemy, P; Juhan, C

    1994-11-01

    Little data are available concerning the relation between the muscular pumping mechanism and the variation of superficial and deep venous pressure during normal action of the calf pump; therefore we undertook this study to determine the pressure values in three compartments of the calf and in the deep and the superficial venous system and to establish correlation between muscular and venous pressure. Nine healthy young women with a mean age of 23 years (range 19 to 28 years) were examined. In the same calf, a muscular catheter was placed in the deep posterior compartment (DPC), in the superficial posterior compartment (SPC), and in the anterior tibial compartment (ATC), and a vascular catheter was placed in the popliteal vein and in the greater saphenous vein (GSV). The five lines of pressure were simultaneously recorded in the following situations: at rest, during Valsalva maneuver, foot flexion, and foot extension. The situation was studied with the patient in the following positions: decubitus, sitting, standing, and squatting. A final continuous recording was carried out after the patient had been walking for 5 minutes. Mean values with standard errors of muscular and venous pressure were established in each situation. At rest and during Valsalva maneuver, the muscular pressures did not vary, whereas venous pressures increased significantly when the patient was sitting and standing. On the other hand, squatting was associated with a rise in the muscular and vein pressures. Foot flexion entailed a significant increase in the ATC pressure and a rise in the GSV pressure, whereas foot extension caused the DPC pressure to rise without venous pressure modifications. Walking was associated with an alternating increase in the DPC, SPC, GSV and popliteal vein pressures when the foot was compressed to floor followed by a significant decrease when the foot pressure was released. The variations in the deep and superficial venous pressures when the patient is sitting and

  13. Study of Bubble Size, Void Fraction, and Mass Transport in a Bubble Column under High Amplitude Vibration

    Directory of Open Access Journals (Sweden)

    Shahrouz Mohagheghian

    2018-04-01

    Full Text Available Vertical vibration is known to cause bubble breakup, clustering and retardation in gas-liquid systems. In a bubble column, vibration increases the mass transfer ratio by increasing the residence time and phase interfacial area through introducing kinetic buoyancy force (Bjerknes effect and bubble breakup. Previous studies have explored the effect of vibration frequency (f, but minimal effort has focused on the effect of amplitude (A on mass transfer intensification. Thus, the current work experimentally examines bubble size, void fraction, and mass transfer in a bubble column under relatively high amplitude vibration (1.5 mm < A <9.5 mm over a frequency range of 7.5–22.5 Hz. Results of the present work were compared with past studies. The maximum stable bubble size under vibration was scaled using Hinze theory for breakage. Results of this work indicate that vibration frequency exhibits local maxima in both mass transfer and void fraction. Moreover, an optimum amplitude that is independent of vibration frequency was found for mass transfer enhancements. Finally, this work suggests physics-based models to predict void fraction and mass transfer in a vibrating bubble column.

  14. Cutting bubbles with a single wire

    NARCIS (Netherlands)

    Baltussen, M.W.; Segers, Q.I.E.; Kuipers, J.A.M.; Deen, N.G.

    2017-01-01

    Many gas-liquid-solid contactors, such as trickle bed and bubble slurry columns, suffer from heat and mass transfer limitations. To overcome these limitations, new micro-structured bubble column reactor is proposed. In this reactor, a catalyst coated wire mesh is introduced in a bubble column to cut

  15. Flow visualization using bubbles

    International Nuclear Information System (INIS)

    Henry, J.P.

    1974-01-01

    Soap bubbles were used for visualizing flows. The tests effected allowed some characteristics of flows around models in blow tunnels to be precised at mean velocities V 0 5 . The velocity of a bubble is measured by chronophotography, the bulk envelope of the trajectories is also registered [fr

  16. Evaluation of hepatic venous pulsatility and portal venous velocity with doppler ultrasonography during the puerperium

    Energy Technology Data Exchange (ETDEWEB)

    Pekindil, Goekhan [Department of Radiology, Trakya University School of Medicine, 22030 Edirne (Turkey); Varol, Fuesun G. [Department of Obstetrics and Gynecology, Trakya University School of Medicine, 22030 Edirne (Turkey); Ali Yuece, M. [Department of Obstetrics and Gynecology, Trakya University School of Medicine, 22030 Edirne (Turkey); Yardim, Turgut [Department of Obstetrics and Gynecology, Trakya University School of Medicine, 22030 Edirne (Turkey)

    1999-03-01

    Objective: The aim of this study is to evaluate pregnancy-induced changes of hepatic venous pulsatility and portal venous velocity in the puerperium and to determine if these changes disappeared by the end of the puerperium. Methods and material: Healthy normal volunteers (90) were examined on the 2nd and 7th days of puerperium and between the 6th and 8th weeks postpartum. Doppler waveform patterns were obtained in the middle hepatic vein and main portal vein. The hepatic venous pulsatility was named as normal, damped or flat. Results: On the 2nd day postpartum, the hepatic vein pulsatility was shown as normal in 8 (26%), damped in 11 (37%) and flat in 11 (37%) cases. On the 7th day postpartum, 15 (50%) cases had normal, 9 (30%) cases had dampened, and 6 (20%) cases had still flat pattern. The majority of the cases (60%) displayed normal hepatic venous pulsatility in the 6th and 8th weeks of puerperium, whereas 23% had still dampened and 17% had flat patterns. There was a trend toward normal pulsatility with increasing puerperal age. The mean portal venous velocity was still higher than the non-pregnant levels and did not showed significant alterations during puerperium. Conclusion: This study emphasised that, since pregnancy-induced alterations in hepatic venous pulsatility and portal venous velocity had not completely returned to normal in most cases until the end of the puerperium, these physiological changes should be considered whenever hepatic and portal systems are interpreted with Doppler sonography during the puerperal period.

  17. Evaluation of hepatic venous pulsatility and portal venous velocity with doppler ultrasonography during the puerperium

    International Nuclear Information System (INIS)

    Pekindil, Goekhan; Varol, Fuesun G.; Ali Yuece, M.; Yardim, Turgut

    1999-01-01

    Objective: The aim of this study is to evaluate pregnancy-induced changes of hepatic venous pulsatility and portal venous velocity in the puerperium and to determine if these changes disappeared by the end of the puerperium. Methods and material: Healthy normal volunteers (90) were examined on the 2nd and 7th days of puerperium and between the 6th and 8th weeks postpartum. Doppler waveform patterns were obtained in the middle hepatic vein and main portal vein. The hepatic venous pulsatility was named as normal, damped or flat. Results: On the 2nd day postpartum, the hepatic vein pulsatility was shown as normal in 8 (26%), damped in 11 (37%) and flat in 11 (37%) cases. On the 7th day postpartum, 15 (50%) cases had normal, 9 (30%) cases had dampened, and 6 (20%) cases had still flat pattern. The majority of the cases (60%) displayed normal hepatic venous pulsatility in the 6th and 8th weeks of puerperium, whereas 23% had still dampened and 17% had flat patterns. There was a trend toward normal pulsatility with increasing puerperal age. The mean portal venous velocity was still higher than the non-pregnant levels and did not showed significant alterations during puerperium. Conclusion: This study emphasised that, since pregnancy-induced alterations in hepatic venous pulsatility and portal venous velocity had not completely returned to normal in most cases until the end of the puerperium, these physiological changes should be considered whenever hepatic and portal systems are interpreted with Doppler sonography during the puerperal period

  18. Modeling of mass transfer and chemical reactions in a bubble column reactor using a discrete bubble model

    NARCIS (Netherlands)

    Darmana, D.; Deen, N.G.; Kuipers, J.A.M.

    2004-01-01

    A 3D discrete bubble model is adopted to investigate complex behavior involving hydrodynamics, mass transfer and chemical reactions in a gas-liquid bubble column reactor. In this model a continuum description is adopted for the liquid phase and additionally each individual bubble is tracked in a

  19. On the mobility of fission-gas bubbles

    International Nuclear Information System (INIS)

    Nichols, F.A.; Ronchi, C.

    1986-01-01

    The importance of bubble migration in fuel swelling and fission-product release remains a controversial topic in spite of a great deal of research. For steady state analyses some authors ignore bubble motion totally, whereas others use mobilities (based on out-of-pile measurements) which are far below the theoretical diffusion-control predictions. Under transient conditions some continue to use zero or low bubble mobilities, whereas others invoke higher mobilities. Experimental information on mobility of bubbles under irradiation conditions is very limited, but supports the theoretical values for bubble sizes above 1 μm. The authors discuss here some interesting new results which may provide direct evidence for in-pile mobilities comparable with surface-diffusion control predictions for much smaller bubbles (<20nm), where out-of-pile studies indicate greatly reduced mobilities. A brief summary is presented of information available for bubble mobilities, both in- and out-of-pile

  20. Influence of fentanyl and morphine on intestinal circulation

    International Nuclear Information System (INIS)

    Tverskoy, M.; Gelman, S.; Fowler, K.C.; Bradley, E.L.

    1985-01-01

    The influence of fentanyl and morphine on the intestinal circulation was evaluated in an isolated loop preparation in 37 dogs anesthetized with pentobarbital intravenously. Selected intestinal segments were pumped with aortic blood at a constant pressure of 100 mm Hg. A mixture of 86 Rb and 9-micron spheres labeled with 141 Ce was injected into the arterial cannula supplying the intestinal loop, while mesenteric venous blood was collected for activity counting. A strong correlation was found between the clearances of rubidium and microspheres (r = 0.97, P less than 0.0001), suggesting that the shunting of 9-micron spheres through the intestines reflects the shunting of blood through nonnutritive vessels. Intravenous fentanyl decreased oxygen uptake (O 2 up), and vascular resistance (VR), and increased blood flow (BF), rubidium and microsphere clearances (Cl-Rb, Cl-Sph, respectively), and permeability--surface area product (PS) in a dose-related fashion. Intravenous morphine in a dose of 1 mg X kg-1 increased Cl-Rb (nutritive BF) without changes in total (nutritive and nonnutritive) BF. This increase in nutritive BF is probably related to morphine-induced histamine release. Morphine in a dose of 5 mg X kg-1 was accompanied by vasoconstriction that was completely abolished by alpha-adrenoceptor blockade. The data suggest that morphine-induced intestinal vasoconstriction is mediated via a release of epinephrine, apparently from the adrenal medulla. It is concluded that changes in the intestinal circulation during anesthesia with narcotics might play a certain role in the cardiovascular homeostasis during anesthesia and surgery. An increase in oxygen content in portal venous blood, resulting from a decrease in intestinal oxygen uptake, should facilitate hepatic oxygenation

  1. Influence of fentanyl and morphine on intestinal circulation

    Energy Technology Data Exchange (ETDEWEB)

    Tverskoy, M.; Gelman, S.; Fowler, K.C.; Bradley, E.L.

    1985-06-01

    The influence of fentanyl and morphine on the intestinal circulation was evaluated in an isolated loop preparation in 37 dogs anesthetized with pentobarbital intravenously. Selected intestinal segments were pumped with aortic blood at a constant pressure of 100 mm Hg. A mixture of /sup 86/Rb and 9-micron spheres labeled with /sup 141/Ce was injected into the arterial cannula supplying the intestinal loop, while mesenteric venous blood was collected for activity counting. A strong correlation was found between the clearances of rubidium and microspheres (r = 0.97, P less than 0.0001), suggesting that the shunting of 9-micron spheres through the intestines reflects the shunting of blood through nonnutritive vessels. Intravenous fentanyl decreased oxygen uptake (O/sub 2/up), and vascular resistance (VR), and increased blood flow (BF), rubidium and microsphere clearances (Cl-Rb, Cl-Sph, respectively), and permeability--surface area product (PS) in a dose-related fashion. Intravenous morphine in a dose of 1 mg X kg-1 increased Cl-Rb (nutritive BF) without changes in total (nutritive and nonnutritive) BF. This increase in nutritive BF is probably related to morphine-induced histamine release. Morphine in a dose of 5 mg X kg-1 was accompanied by vasoconstriction that was completely abolished by alpha-adrenoceptor blockade. The data suggest that morphine-induced intestinal vasoconstriction is mediated via a release of epinephrine, apparently from the adrenal medulla. It is concluded that changes in the intestinal circulation during anesthesia with narcotics might play a certain role in the cardiovascular homeostasis during anesthesia and surgery. An increase in oxygen content in portal venous blood, resulting from a decrease in intestinal oxygen uptake, should facilitate hepatic oxygenation.

  2. Bubbles and breaking waves

    Science.gov (United States)

    Thorpe, S. A.

    1980-01-01

    The physical processes which control the transfer of gases between the atmosphere and oceans or lakes are poorly understood. Clouds of micro-bubbles have been detected below the surface of Loch Ness when the wind is strong enough to cause the waves to break. The rate of transfer of gas into solution from these bubbles is estimated to be significant if repeated on a global scale. We present here further evidence that the bubbles are caused by breaking waves, and discuss the relationship between the mean frequency of wave breaking at a fixed point and the average distance between breaking waves, as might be estimated from an aerial photograph.

  3. Electron acceleration in the bubble regime

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, Oliver

    2014-02-03

    The bubble regime of laser-wakefield acceleration has been studied over the recent years as an important alternative to classical accelerators. Several models and theories have been published, in particular a theory which provides scaling laws for acceleration parameters such as energy gain and acceleration length. This thesis deals with numerical simulations within the bubble regime, their comparison to these scaling laws and data obtained from experiments, as well as some specific phenomenona. With a comparison of the scaling laws with numerical results a parameter scan was able to show a large parameter space in which simulation and theory agree. An investigation of the limits of this parameter space revealed boundaries to other regimes, especially at very high (a{sub 0} > 100) and very low laser amplitudes (a{sub 0} < 4). Comparing simulation data with data from experiments concerning laser pulse development and electron energies, it was found that experimental results can be adequately reproduced using the Virtual-Laser-Plasma-Laboratory code. In collaboration with the Institut fuer Optik und Quantenelektronik at the Friedrich-Schiller University Jena synchrotron radiation emitted from the inside of the bubble was investigated. A simulation of the movement of the electrons inside the bubble together with time dependent histograms of the emitted radiation helped to prove that the majority of radiation created during a bubble acceleration originates from the inside of the bubble. This radiation can be used to diagnose the amplitude of oscillation of the trapped electrons. During a further study it was proven that the polarisation of synchrotron radiation from a bubble contains information about the exact oscillation direction. This oscillation was successfully controlled by using either a laser pulse with a tilted pulse front or an asymmetric laser pulse. First results of ongoing studies concerning injecting electrons into an existing bubble and a scheme called

  4. Motion of air bubbles in stagnant water condition

    International Nuclear Information System (INIS)

    Bezdegumeli, U.; Ozdemir, S.; Yesin, O.

    2004-01-01

    Full text: In this study, air bubble motion in stagnant water condition in a vertical pipe is investigated experimentally. For this purpose, a test set-up was designed and constructed. Motions of single bubbles, having different diameters in the range of 3.0-4.8 mm, were recorded by using a monochrome camera, an image capture card and a PC. Recorded video images were processed to analyse bubble motion and to obtain the necessary data. The purpose of the study is to determine the variation of bubble axial velocity and bubble drag coefficient as a function of equivalent bubble diameter and bubble Reynolds number, Re b . Therefore, detailed information for this range of bubble diameters was obtained. The results have shown good consistency with the previous studies found in the literature

  5. Motion of air bubbles in stagnant water condition

    International Nuclear Information System (INIS)

    Bezdegumeli, U.; Ozdemir, S.; Yesin, O.

    2004-01-01

    In this study, air bubble motion in stagnant water condition in a vertical pipe of 4.6 cm diameter is investigated experimentally. For this purpose, a test set-up was designed and constructed. Motions of single bubbles, having different diameters in the range of 3.0-4.8 mm, were recorded by using a monochrome camera, an image capture card and a PC. Recorded video images were processed to analyse bubble motion and to obtain the necessary data. The purpose of the study is to determine the variation of bubble axial velocity and bubble drag coefficient as a function of equivalent bubble diameter and bubble Reynolds number, Re b . Therefore, detailed information for this range of bubble diameters was obtained. The results have shown good consistency with the previous studies found in the literature. (author)

  6. Turbulence, bubbles and drops

    NARCIS (Netherlands)

    van der Veen, Roeland

    2016-01-01

    In this thesis, several questions related to drop impact and Taylor-Couette turbulence are answered. The deformation of a drop just before impact can cause a bubble to be entrapped. For many applications, such as inkjet printing, it is crucial to control the size of this entrapped bubble. To study

  7. A Novel Stretch Sensor to Measure Venous Hemodynamics

    Directory of Open Access Journals (Sweden)

    Syrpailyne Wankhar

    2018-07-01

    Full Text Available Chronic venous insufficiency is a debilitating condition causing varicose veins and venous ulcers. The pathophysiology includes reflux and venous obstruction. The diagnosis is often made by clinical examination and confirmed by Venous Doppler studies. Plethysmography helps to quantitatively examine the reflux and diagnose the burden of deep venous pathology to better understand venous hemodynamics, which is not elicited by venous duplex examination alone. However, most of these tests are qualitative, expensive, and not easily available. In this paper, we demonstrate the potential use of a novel stretch sensor in the assessment of venous hemodynamics during different maneuvers by measuring the change in calf circumference. We designed the stretch sensor by using semiconductor strain gauges pasted onto a small metal bar to form a load cell. The elastic and Velcro material attached to the load cell form a belt. It converts the change in limb circumference to a proportional tension (force of distension when placed around the calf muscle. We recorded the change in limb circumference from arrays of stretch sensors by using an in-house data acquisition system. We calculated the venous volume (VV, venous filling index (VFI, ejection fraction (EF and residual venous volume (RVV on two normal subjects and on two patients to assess venous hemodynamics. The values (VV > 60 ml, VFI 60%, RVV 2ml/s, EF 35% in patients were comparable to those reported in the literature.

  8. Desulphurization in peat-fired circulating and bubbling fluidized bed boilers

    Energy Technology Data Exchange (ETDEWEB)

    Kouvo, P. [Imatran Voima Oy, Vantaa (Finland); Salmenoja, K. [Kvaerner Pulping Oy, Tampere (Finland)

    1997-12-31

    The new emission limit values for large combustion plants are under consideration both at the EU level and in Finland. Peat and wood are the only indigenous fuels of Finland. In 1995 appr. 8 % of electricity was produced with peat. The lower heating value of peat is around 10 MJ/kg. The moisture content varies between 35-55 % and sulphur content in dry solids between 0.15-0.35 %. The total peat power capacity of Finland in 1995 was 1400 MW. Because there was not enough information available about the desulphurization of the flue gases from peat-fired fluidized bed boilers, a group of Finnish companies and Ministry of Trade and Industry decided to carry out the full-scale desulphurisation study. In the project the desulphurization with limestone injection into the furnace of two types of peat-fired boilers were studied. The goal of the project was to investigate: what the technically and economically feasible emission level is by limestone injection in the fluidized bed combustion; how the limestone injection affects the other flue gas emissions and the fouling of the boiler and, what the economy of desulphurisation is. The tests were carried out at Kokkola and Kemi power plants in Finland. At Kokkola (108 MW{sub f}) circulating fluidized bed boiler, the emission limit of 200 mg/m{sup 3}n was leached at a Ca/S-molar ratio of appr. 10, with limestone containing 92 % of calcium carbonate, CaCO{sub 3}. At Kemi (267 MW{sub f}) bubbling fluidized bed boiler, the emission limit of 280 mg/m{sup 3}n with limestone containing appr. 95 % of CaCO{sub 3} was reached at a Ca/S-molar ratio of appr. 7.0. Emissions of NO{sub x}, N{sub 2}O, NH{sub 3} and dust after the ESP were not elevated due to the limestone feed. At the Kokkola power plant the NO{sub x} emissions varied from 300 to 400 mg/m{sup 3}n, and, at the Kemi power station the NO{sub x} emissions were around 200 mg/m{sup 3}n. The fouling of the Kemi boiler was found to be significant in the scheduled outage after the test

  9. Average properties of bidisperse bubbly flows

    Science.gov (United States)

    Serrano-García, J. C.; Mendez-Díaz, S.; Zenit, R.

    2018-03-01

    Experiments were performed in a vertical channel to study the properties of a bubbly flow composed of two distinct bubble size species. Bubbles were produced using a capillary bank with tubes with two distinct inner diameters; the flow through each capillary size was controlled such that the amount of large or small bubbles could be controlled. Using water and water-glycerin mixtures, a wide range of Reynolds and Weber number ranges were investigated. The gas volume fraction ranged between 0.5% and 6%. The measurements of the mean bubble velocity of each species and the liquid velocity variance were obtained and contrasted with the monodisperse flows with equivalent gas volume fractions. We found that the bidispersity can induce a reduction of the mean bubble velocity of the large species; for the small size species, the bubble velocity can be increased, decreased, or remain unaffected depending of the flow conditions. The liquid velocity variance of the bidisperse flows is, in general, bound by the values of the small and large monodisperse values; interestingly, in some cases, the liquid velocity fluctuations can be larger than either monodisperse case. A simple model for the liquid agitation for bidisperse flows is proposed, with good agreement with the experimental measurements.

  10. Influences of non-uniform pressure field outside bubbles on the propagation of acoustic waves in dilute bubbly liquids.

    Science.gov (United States)

    Zhang, Yuning; Du, Xiaoze

    2015-09-01

    Predictions of the propagation of the acoustic waves in bubbly liquids is of great importance for bubble dynamics and related applications (e.g. sonochemistry, sonochemical reactor design, biomedical engineering). In the present paper, an approach for modeling the propagation of the acoustic waves in dilute bubbly liquids is proposed through considering the non-uniform pressure field outside the bubbles. This approach is validated through comparing with available experimental data in the literature. Comparing with the previous models, our approach mainly improves the predictions of the attenuation of acoustic waves in the regions with large kR0 (k is the wave number and R0 is the equilibrium bubble radius). Stability of the oscillating bubbles under acoustic excitation are also quantitatively discussed based on the analytical solution. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Bifurcation scenarios for bubbling transition.

    Science.gov (United States)

    Zimin, Aleksey V; Hunt, Brian R; Ott, Edward

    2003-01-01

    Dynamical systems with chaos on an invariant submanifold can exhibit a type of behavior called bubbling, whereby a small random or fixed perturbation to the system induces intermittent bursting. The bifurcation to bubbling occurs when a periodic orbit embedded in the chaotic attractor in the invariant manifold becomes unstable to perturbations transverse to the invariant manifold. Generically the periodic orbit can become transversely unstable through a pitchfork, transcritical, period-doubling, or Hopf bifurcation. In this paper a unified treatment of the four types of bubbling bifurcation is presented. Conditions are obtained determining whether the transition to bubbling is soft or hard; that is, whether the maximum burst amplitude varies continuously or discontinuously with variation of the parameter through its critical value. For soft bubbling transitions, the scaling of the maximum burst amplitude with the parameter is derived. For both hard and soft transitions the scaling of the average interburst time with the bifurcation parameter is deduced. Both random (noise) and fixed (mismatch) perturbations are considered. Results of numerical experiments testing our theoretical predictions are presented.

  12. High-Flow Renal Arteriovenous Fistula Treated with the Amplatzer Vascular Plug: Implementation of an Arterial and Venous Approach

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Ptohis, Nikolaos; Grammenou-Pomoni, Maria; Panagiotou, Irini; Kelekis, Dimitrios; Gouliamos, Athanasios; Kelekis, Nikolaos

    2009-01-01

    We present a 28-year-old man with a large symptomatic arteriovenous fistula (AVF) treated with embolization using the Amplatzer vascular plug (AVP). Although embolization may be considered the first-line therapy in the treatment of AVFs, there is an inherent high risk of migration of the embolic agents into the venous and pulmonary circulations. This case is illustrative of the ease and safety of using this device in high-flow renal AVFs.

  13. The Minnaert bubble: an acoustic approach

    Energy Technology Data Exchange (ETDEWEB)

    Devaud, Martin; Hocquet, Thierry; Bacri, Jean-Claude [Laboratoire Matiere et Systemes Complexes, Universite Paris Diderot and CNRS UMR 7057, 10 rue Alice Domont et Leonie Duquet, 75013 Paris (France); Leroy, Valentin [Laboratoire Ondes et Acoustique, Universite Paris 7 and CNRS UMR 7587, ESPCI, 10 rue Vauquelin, 75005 Paris (France)], E-mail: martin.devaud@univ-paris-diderot.fr

    2008-11-15

    We propose an ab initio introduction to the well-known Minnaert pulsating bubble at graduate level. After a brief recall of the standard stuff, we begin with a detailed discussion of the radial movements of an air bubble in water. This discussion is managed from an acoustic point of view, and using the Lagrangian rather than the Eulerian variables. In unbounded water, the air-water system has a continuum of eigenmodes, some of them correspond to regular Fabry-Perot resonances. A singular resonance, the lowest one, is shown to coincide with that of Minnaert. In bounded water, the eigenmodes spectrum is discrete, with a finite fundamental frequency. A spectacular quasi-locking of the latter occurs if it happens to exceed the Minnaert frequency, which provides an unforeseen one-bubble alternative version of the famous 'hot chocolate effect'. In the (low) frequency domain in which sound propagation inside the bubble reduces to a simple 'breathing' (i.e. inflation/deflation), the light air bubble can be 'dressed' by the outer water pressure forces, and is turned into the heavy Minnaert bubble. Thanks to this unexpected renormalization process, we demonstrate that the Minnaert bubble definitely behaves like a true harmonic oscillator of the spring-bob type, but with a damping term and a forcing term in apparent disagreement with those commonly admitted in the literature. Finally, we underline the double role played by the water. In order to tell the water motion associated with water compressibility (i.e. the sound) from the simple incompressible accompaniment of the bubble breathing, we introduce a new picture analogous to the electromagnetic radiative picture in Coulomb gauge, which naturally leads us to split the water displacement in an instantaneous and a retarded part. The Minnaert renormalized mass of the dressed bubble is then automatically recovered.

  14. A bubble detection system for propellant filling pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Wen, Wen; Zong, Guanghua; Bi, Shusheng [Robotics Institute, Beihang University, 100191 Beijing (China)

    2014-06-15

    This paper proposes a bubble detection system based on the ultrasound transmission method, mainly for probing high-speed bubbles in the satellite propellant filling pipeline. First, three common ultrasonic detection methods are compared and the ultrasound transmission method is used in this paper. Then, the ultrasound beam in a vertical pipe is investigated, suggesting that the width of the beam used for detection is usually smaller than the internal diameter of the pipe, which means that when bubbles move close to the pipe wall, they may escape from being detected. A special device is designed to solve this problem. It can generate the spiral flow to force all the bubbles to ascend along the central line of the pipe. In the end, experiments are implemented to evaluate the performance of this system. Bubbles of five different sizes are generated and detected. Experiment results show that the sizes and quantity of bubbles can be estimated by this system. Also, the bubbles of different radii can be distinguished from each other. The numerical relationship between the ultrasound attenuation and the bubble radius is acquired and it can be utilized for estimating the unknown bubble size and measuring the total bubble volume.

  15. Gas Bubble Dynamics under Mechanical Vibrations

    Science.gov (United States)

    Mohagheghian, Shahrouz; Elbing, Brian

    2017-11-01

    The scientific community has a limited understanding of the bubble dynamics under mechanical oscillations due to over simplification of Navier-Stockes equation by neglecting the shear stress tensor and not accounting for body forces when calculating the acoustic radiation force. The current work experimental investigates bubble dynamics under mechanical vibration and resulting acoustic field by measuring the bubble size and velocity using high-speed imaging. The experimental setup consists of a custom-designed shaker table, cast acrylic bubble column, compressed air injection manifold and an optical imaging system. The mechanical vibrations resulted in accelerations between 0.25 to 10 times gravitational acceleration corresponding to frequency and amplitude range of 8 - 22Hz and 1 - 10mm respectively. Throughout testing the void fraction was limited to <5%. The bubble size is larger than resonance size and smaller than acoustic wavelength. The amplitude of acoustic pressure wave was estimated using the definition of Bjerknes force in combination with Rayleigh-Plesset equation. Physical behavior of the system was capture and classified. Bubble size, velocity as well as size and spatial distribution will be presented.

  16. [Effects of combined action of radon baths and transcranial magnetotherapy on cerebral circulation in patients in an intermediate period of a mild craniocerebral trauma].

    Science.gov (United States)

    Moliavchikova, O V; Cherevashchenko, L A; Grinzaĭd, Iu M; Aĭvazov, V N; Zhuravlev, M E

    2007-01-01

    The authors propose combined therapy improving cerebral circulation in patients in an intermediate period of a mild craniocerebral trauma. The combination consists of radon baths and transcranial magnetotherapy which raise blood volume filling, relieve vascular resistance, improve venous outflow.

  17. An experimental study on two-phase flow pattern in low pressure natural circulation system

    International Nuclear Information System (INIS)

    Wu Shaorong; Han Bing; Zhou Lei; Zhang Youjie; Jiang Shengyao; Wu Xinxin

    1991-10-01

    An experimental study on two-phase flow pattern in the riser of low pressure natural circulation system was performed. The local differential pressure signal was analysed for flow pattern. It is considered that Sr f·d/v can be used to distinguish different flow patterns and it has clear and definite physical meaning. Flow patterns at different inlet temperature with different system pressures (1.5 MPa, 0.24 MPa and 0.1 MPa) are described. It is considered that the flow pattern is only bubble flow without flow pattern change during the period of low quality density-wave instability at 1.5 MPa. There is no density-wave oscillation in the system, when flow pattern is in bubble-intermittent transition area. The effect of flash vaporization on stability at low pressure is discussed

  18. Interferometric measurement of film thickness during bubble blowing

    Science.gov (United States)

    Wang, Z.; Mandracchia, B.; Ferraro, V.; Tammaro, D.; Di Maio, E.; Maffettone, P. L.; Ferraro, P.

    2017-06-01

    In this paper, we propose digital holography in transmission configuration as an effective method to measure the time-dependent thickness of polymeric films during bubble blowing. We designed a complete set of experiments to measure bubble thickness, including the evaluation of the refractive index of the polymer solution. We report the measurement of thickness distribution along the film during the bubble formation process until the bubble`s rupture. Based on those data, the variation range and variation trend of bubble film thickness are clearly measured during the process of expansion to fracture is indicated.

  19. Rational Asset Pricing Bubbles Revisited

    OpenAIRE

    Jan Werner

    2012-01-01

    Price bubble arises when the price of an asset exceeds the asset's fundamental value, that is, the present value of future dividend payments. The important result of Santos and Woodford (1997) says that price bubbles cannot exist in equilibrium in the standard dynamic asset pricing model with rational agents as long as assets are in strictly positive supply and the present value of total future resources is finite. This paper explores the possibility of asset price bubbles when either one of ...

  20. Bernoulli Suction Effect on Soap Bubble Blowing?

    Science.gov (United States)

    Davidson, John; Ryu, Sangjin

    2015-11-01

    As a model system for thin-film bubble with two gas-liquid interfaces, we experimentally investigated the pinch-off of soap bubble blowing. Using the lab-built bubble blower and high-speed videography, we have found that the scaling law exponent of soap bubble pinch-off is 2/3, which is similar to that of soap film bridge. Because air flowed through the decreasing neck of soap film tube, we studied possible Bernoulli suction effect on soap bubble pinch-off by evaluating the Reynolds number of airflow. Image processing was utilized to calculate approximate volume of growing soap film tube and the volume flow rate of the airflow, and the Reynolds number was estimated to be 800-3200. This result suggests that soap bubbling may involve the Bernoulli suction effect.

  1. A Bubble-Based Drag Model at the Local-Grid Level for Eulerian Simulation of Bubbling Fluidized Beds

    Directory of Open Access Journals (Sweden)

    Kun Hong

    2016-01-01

    Full Text Available A bubble-based drag model at the local-grid level is proposed to simulate gas-solid flows in bubbling fluidized beds of Geldart A particles. In this model, five balance equations are derived from the mass and the momentum conservation. This set of equations along with necessary correlations for bubble diameter and voidage of emulsion phase is solved to obtain seven local structural parameters (uge, upe, εe, δb, ub, db, and ab which describe heterogeneous flows of bubbling fluidized beds. The modified drag coefficient obtained from the above-mentioned structural parameters is then incorporated into the two-fluid model to simulate the hydrodynamics of Geldart A particles in a lab-scale bubbling fluidized bed. The comparison between experimental and simulation results for the axial and radial solids concentration profiles is promising.

  2. Soap Bubbles and Crystals

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 11; Issue 6. Soap Bubbles and Crystals. Jean E Taylor. General Article Volume 11 Issue 6 June 2006 pp 26-30. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/011/06/0026-0030. Keywords. Soap bubble ...

  3. Non-intuitive bubble effects in reactor and containment technology

    International Nuclear Information System (INIS)

    Moody, F.J.

    1991-01-01

    Most people know a lot about bubbles, including how they rise in liquids and the way they appear when the cap is removed from a bottle of carbonated beverage. A lot of bubble knowledge is obtained from bubbling air through water in aquariums to keep the fish alive and happy, or watching scuba divers feed the sharks in large glass tanks at the local zoo. But innocent bubbles can be sources of structural loadings and sometimes destructive fluid behavior. In fact, there are many non-intuitive effects associated with bubbles which have been discovered by experiments and analyses. It has been necessary to design various reactor and containment components in the nuclear energy industry to accommodate the fact that bubbles can expand like compressed springs, or oscillate, or collapse abruptly, and create structural loads. This paper describes several important phenomena associated with bubble action in nuclear reactor and containment systems and the associated loads exerted. An awareness of these effects can help to avoid unwelcome surprises in general thermal-hydraulic applications when a system is disturbed by bubble behavior. Major topics discussed include expanding and collapsing submerged bubbles, steam chugging and ringout, bubble shattering, surprising hot bubble action in a saturated pool, bubble effects on fluid-structure-interaction, waterhammer from collapsing bubble in pipes, and vapor bubble effects on sound speed in saturated mixtures

  4. Current concepts in repair of extremity venous injury.

    Science.gov (United States)

    Williams, Timothy K; Clouse, W Darrin

    2016-04-01

    Extremity venous injury management remains controversial. The purpose of this communication is to offer perspective as well as experiential and technical insight into extremity venous injury repair. Available literature is reviewed and discussed. Historical context is provided. Indication, the decision process for repair, including technical conduct, is delineated. In particular, the authors' experiences in both civilian and wartime injury are used for perspective. Extremity venous injury repair was championed within data from the Vietnam Vascular Registry. However, patterns of extremity venous injury differ between combat and civilian settings. Since Vietnam, civilian descriptive series opine the benefits and potential complications associated with both venous injury repair and ligation. These surround extremity edema, chronic venous insufficiency, thromboembolism, and limb loss. Whereas no clear superiority in either approach has been identified to date, there appears to be no increased risk of pulmonary embolism or chronic venous changes with repair. Newer data from the wars in Iraq and Afghanistan and meta-analysis have reinforced this and also have suggested limb salvage benefit for extremity venous repair in combined arterial and venous injuries in modern settings. The patient's physiologic state and associated injury drive five triage categories suggesting vein injury management. Vein repair thrombosis occurs in a significant proportion, yet many recanalize and possibly have a positive impact on limb venous return. Further, early decompression favors reduced blood loss, acute edema, and inflammation, supporting collateral development. Large soft tissue injury minimizing collateral capacity increases the importance of repair. Constructs of repair are varied with modest differences in patency. Venous shunting is feasible, but specific roles remain nebulous. An aggressive posture toward extremity venous injury repair seems justified today because of the likely

  5. Single DNA denaturation and bubble dynamics

    DEFF Research Database (Denmark)

    Metzler, Ralf; Ambjörnsson, Tobias; Hanke, Andreas

    2009-01-01

    While the Watson-Crick double-strand is the thermodynamically stable state of DNA in a wide range of temperature and salt conditions, even at physiological conditions local denaturation bubbles may open up spontaneously due to thermal activation. By raising the ambient temperature, titration......, or by external forces in single molecule setups bubbles proliferate until full denaturation of the DNA occurs. Based on the Poland-Scheraga model we investigate both the equilibrium transition of DNA denaturation and the dynamics of the denaturation bubbles with respect to recent single DNA chain experiments...... for situations below, at, and above the denaturation transition. We also propose a new single molecule setup based on DNA constructs with two bubble zones to measure the bubble coalescence and extract the physical parameters relevant to DNA breathing. Finally we consider the interplay between denaturation...

  6. Modelling of boiling bubbly flows using a polydisperse approach

    International Nuclear Information System (INIS)

    Zaepffel, D.

    2011-01-01

    The objective of this work was to improve the modelling of boiling bubbly flows.We focused on the modelling of the polydisperse aspect of a bubble population, i.e. the fact that bubbles have different sizes and different velocities. The multi-size aspect of a bubble population can originate from various mechanisms. For the bubbly flows we are interested in, bubble coalescence, bubble break-up, phase change kinematics and/or gas compressibility inside the bubbles can be mentioned. Since, bubble velocity depends on bubble size, the bubble size spectrum also leads to a bubble velocity spectrum. An averaged model especially dedicated to dispersed flows is introduced in this thesis. Closure of averaged interphase transfer terms are written in a polydisperse framework, i.e. using a distribution function of the bubble sizes and velocities. A quadratic law and a cubic law are here proposed for the modelling of the size distribution function, whose evolution in space and time is then obtained with the use of the moment method. Our averaged model has been implemented in the NEPTUNE-CFD computation code in order to simulate the DEBORA experiment. The ability of our model to deal with sub-cooled boiling flows has therefore been evaluated. (author) [fr

  7. Evaporation, Boiling and Bubbles

    Science.gov (United States)

    Goodwin, Alan

    2012-01-01

    Evaporation and boiling are both terms applied to the change of a liquid to the vapour/gaseous state. This article argues that it is the formation of bubbles of vapour within the liquid that most clearly differentiates boiling from evaporation although only a minority of chemistry textbooks seems to mention bubble formation in this context. The…

  8. The interaction between multiple bubbles and the free surface

    International Nuclear Information System (INIS)

    Zhang Aman; Yao Xiongliang

    2008-01-01

    The flow is assumed to be potential, and a boundary integral method is used to solve the Laplace equation for the velocity potential to investigate the shape and the position of the bubble. A 3D code to study the bubble dynamics is developed, and the calculation results agree well with the experimental data. Numerical analyses are carried out for the interaction between multiple bubbles near the free surface including in-phase and out-of-phase bubbles. The calculation result shows that the bubble period increases with the decrease of the distance between bubble centres because of the depression effect between multiple bubbles. The depression has no relationship with the free surface and it is more apparent for out-of-phase bubbles. There are great differences in dynamic behaviour between the in-phase bubbles and the out-of-phase bubbles due to the depression effect. Furthermore, the interaction among eight bubbles is simulated with a three-dimensional model, and the evolving process and the relevant physical phenomena are presented. These phenomena can give a reference to the future work on the power of bubbles induced by multiple charges exploding simultaneously or continuously

  9. Cerebral venous thrombosis

    International Nuclear Information System (INIS)

    Soralova, T.; Sevcikova, H.; Petersky, D.

    2014-01-01

    We decided to process this theme due to its nonspecific clinical features as they often cause diagnostic problems not only to clinicians but also to diagnostic. It is important to think of this disease mainly in young women who administer hormonal contraception. Imaging methods play the crucial role in diagnostic of cerebral venous sinus thrombosis. The gold standard is a native CT of brain which shows the venous sinus thrombosis as a hyperdense lesion in the locus of the sinus (dense triangle sign), CT venography shows the sinus thrombosis as a defect in a contrast filling of the venous sinus (empty delta sign). Other investigative methods are magnetic resonance imaging or MRA. In short we also mention quite a rare but more serious thrombosis of profound cerebral veins v. cerebri magna-Galeni, vv. cerebri internae). The importance of early diagnostic and non specificity of symptoms is presented in 3 clinical cases that are the part of this work. (author)

  10. Lattice Boltzmann Simulation of Multiple Bubbles Motion under Gravity

    Directory of Open Access Journals (Sweden)

    Deming Nie

    2015-01-01

    Full Text Available The motion of multiple bubbles under gravity in two dimensions is numerically studied through the lattice Boltzmann method for the Eotvos number ranging from 1 to 12. Two kinds of initial arrangement are taken into account: vertical and horizontal arrangement. In both cases the effects of Eotvos number on the bubble coalescence and rising velocity are investigated. For the vertical arrangement, it has been found that the coalescence pattern is similar. The first coalescence always takes place between the two uppermost bubbles. And the last coalescence always takes place between the coalesced bubble and the bottommost bubble. For four bubbles in a horizontal arrangement, the outermost bubbles travel into the wake of the middle bubbles in all cases, which allows the bubbles to coalesce. The coalescence pattern is more complex for the case of eight bubbles, which strongly depends on the Eotvos number.

  11. Detailed modeling of hydrodynamics mass transfer and chemical reactions in a bubble column using a discrete bubble model

    NARCIS (Netherlands)

    Darmana, D.; Deen, N.G.; Kuipers, J.A.M.

    2005-01-01

    A 3D discrete bubble model is adopted to investigate complex behavior involving hydrodynamics, mass transfer and chemical reactions in a gas–liquid bubble column reactor. In this model a continuum description is adopted for the liquid phase and additionally each individual bubble is tracked in a

  12. Fluid dynamics of bubbly flows

    International Nuclear Information System (INIS)

    Ziegenhein, Thomas

    2016-01-01

    Bubbly flows can be found in many applications in chemical, biological and power engineering. Reliable simulation tools of such flows that allow the design of new processes and optimization of existing one are therefore highly desirable. CFD-simulations applying the multi-fluid approach are very promising to provide such a design tool for complete facilities. In the multi-fluid approach, however, closure models have to be formulated to model the interaction between the continuous and dispersed phase. Due to the complex nature of bubbly flows, different phenomena have to be taken into account and for every phenomenon different closure models exist. Therefore, reliable predictions of unknown bubbly flows are not yet possible with the multi-fluid approach. A strategy to overcome this problem is to define a baseline model in which the closure models including the model constants are fixed so that the limitations of the modeling can be evaluated by validating it on different experiments. Afterwards, the shortcomings are identified so that the baseline model can be stepwise improved without losing the validity for the already validated cases. This development of a baseline model is done in the present work by validating the baseline model developed at the Helmholtz-Zentrum Dresden-Rossendorf mainly basing on experimental data for bubbly pipe flows to bubble columns, bubble plumes and air-lift reactors that are relevant in chemical and biological engineering applications. In the present work, a large variety of such setups is used for validation. The buoyancy driven bubbly flows showed thereby a transient behavior on the scale of the facility. Since such large scales are characterized by the geometry of the facility, turbulence models cannot describe them. Therefore, the transient simulation of bubbly flows with two equation models based on the unsteady Reynolds-averaged Navier-Stokes equations is investigated. In combination with the before mentioned baseline model these

  13. Fluid dynamics of bubbly flows

    Energy Technology Data Exchange (ETDEWEB)

    Ziegenhein, Thomas

    2016-07-08

    Bubbly flows can be found in many applications in chemical, biological and power engineering. Reliable simulation tools of such flows that allow the design of new processes and optimization of existing one are therefore highly desirable. CFD-simulations applying the multi-fluid approach are very promising to provide such a design tool for complete facilities. In the multi-fluid approach, however, closure models have to be formulated to model the interaction between the continuous and dispersed phase. Due to the complex nature of bubbly flows, different phenomena have to be taken into account and for every phenomenon different closure models exist. Therefore, reliable predictions of unknown bubbly flows are not yet possible with the multi-fluid approach. A strategy to overcome this problem is to define a baseline model in which the closure models including the model constants are fixed so that the limitations of the modeling can be evaluated by validating it on different experiments. Afterwards, the shortcomings are identified so that the baseline model can be stepwise improved without losing the validity for the already validated cases. This development of a baseline model is done in the present work by validating the baseline model developed at the Helmholtz-Zentrum Dresden-Rossendorf mainly basing on experimental data for bubbly pipe flows to bubble columns, bubble plumes and air-lift reactors that are relevant in chemical and biological engineering applications. In the present work, a large variety of such setups is used for validation. The buoyancy driven bubbly flows showed thereby a transient behavior on the scale of the facility. Since such large scales are characterized by the geometry of the facility, turbulence models cannot describe them. Therefore, the transient simulation of bubbly flows with two equation models based on the unsteady Reynolds-averaged Navier-Stokes equations is investigated. In combination with the before mentioned baseline model these

  14. Cap Bubble Drift Velocity in a Confined Test Section

    International Nuclear Information System (INIS)

    Xiaodong Sun; Seungjin Kim; Mamoru Ishii; Lincoln, Frank W.; Beus, Stephen G.

    2002-01-01

    In the two-group interfacial area transport equation, bubbles are categorized into two groups, i.e., spherical/distorted bubbles as group 1 and cap/slug/churn-turbulent bubbles as group 2. The bubble rise velocities for both groups of bubbles may be estimated by the drift flux model by applying different distribution parameters and drift velocities for both groups. However, the drift velocity for group 2 bubbles is not always applicable (when the wall effect becomes important) as in the current test loop of interest where the flow channel is confined by two parallel flat walls, with a dimension of 200-mm in width and 10-mm in gap. The previous experiments indicated that no stable slug flow existed in this test section, which was designed to permit visualization of the flow patterns and bubble characteristics without the distortion associated with curved surfaces. In fact, distorted cap bubbly and churn-turbulent flow was observed. Therefore, it is essential to developed a correlation for cap bubble drift velocity in this confined flow channel. Since the rise velocity of a cap bubble depends on its size, a high-speed movie camera is used to capture images of cap bubbles to obtain the bubble size information. Meanwhile, the rise velocity of cap and elongated bubbles (called cap bubbles hereafter) is investigated by examining the captured images frame by frame. As a result, the conventional correlation of drift velocity for slug bubbles is modified and acceptable agreements between the measurements and correlation estimation are achieved

  15. Hydrodynamics in a swarm of rising bubbles

    International Nuclear Information System (INIS)

    Riboux, G.

    2007-04-01

    In many applications, bubbles are used to agitate a liquid in order to enhance mixing and transfer. This work is devoted to the study of the hydrodynamics in a stable bubble column. Experimentally, we have determined the properties of the velocity fluctuations inside and behind a homogeneous swarm of rising bubbles for different bubble sizes and gas volume fractions α: self-similarity in α 0,4 , spectrum in k -3 and integral length scale controlled by buoyancy. Numerically, we have reproduced these properties by means of large-scale simulations, the bubbles being modeled by volume-forces. This confirms that the dynamics is controlled by wake interactions. (author)

  16. Experimental study of natural circulation flow instability in rectangular channels

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Tao; Qi, Shi; Song, Mingqiang [North China Electric Power Univ., Beijing (China). School of Nuclear Science and Engineering; Passive Nuclear Safety Technology, Beijing (China). Beijing Key Lab.; Xiao, Zejun [Nuclear, Reactor Thermal Hydraulics Technology, Chengdu (China). CNNC Key Lab.

    2017-05-15

    Experiments of natural circulation flow instability were conducted in rectangular channels with 5 mm and 10 mm wide gaps. Results for different heating powers were obtained. The results showed that the flow will tend to be instable with the growing of heating power. The oscillation period of pressure D-value and volume flow are the same, but their phase positions are opposite. They both can be described by trigonometric functions. The existence of edge position and secondary flow will strengthen the disturbance of fluid flow in rectangle channels, which contributes to heat transfer. The disturbance of bubble and fluid will be strengthened, especially in the saturated boiling section, which make it possible for the mixing flow. The results also showed that the resistance in 5 mm channel is bigger than that in 10 mm channel, it is less likely to form stable natural circulation in the subcooled region.

  17. Flow visualization of bubble behavior under two-phase natural circulation flow conditions using high speed digital camera

    Energy Technology Data Exchange (ETDEWEB)

    Lemos, Wanderley F.; Su, Jian, E-mail: wlemos@con.ufrj.br, E-mail: sujian@lasme.coppe.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Faccini, Jose L.H., E-mail: faccini@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. de Termo-Hidraulica Experimental

    2013-07-01

    The The present work aims at identifying flow patterns and measuring interfacial parameters in two-phase natural circulation by using visualization technique with high-speed digital camera. The experiments were conducted in the Natural Circulation Circuit (CCN), installed at Nuclear Engineering Institute/CNEN. The thermo-hydraulic circuit comprises heater, heat exchanger, expansion tank, the pressure relief valve and pipes to interconnect the components. A glass tube is installed at the midpoint of the riser connected to the heater outlet. The natural circulation circuit is complemented by acquisition system of values of temperatures, flow and graphic interface. The instrumentation has thermocouples, volumetric flow meter, rotameter and high-speed digital camera. The experimental study is performed through analysis of information from measurements of temperatures at strategic points along the hydraulic circuit, besides natural circulation flow rates. The comparisons between analytical and experimental values are validated by viewing, recording and processing of the images for the flows patterns. Variables involved in the process of identification of flow regimes, dimensionless parameters, the phase velocity of the flow, initial boiling point, the phenomenon of 'flashing' pre-slug flow type were obtained experimentally. (author)

  18. Flow visualization of bubble behavior under two-phase natural circulation flow conditions using high speed digital camera

    International Nuclear Information System (INIS)

    Lemos, Wanderley F.; Su, Jian; Faccini, Jose L.H.

    2013-01-01

    The The present work aims at identifying flow patterns and measuring interfacial parameters in two-phase natural circulation by using visualization technique with high-speed digital camera. The experiments were conducted in the Natural Circulation Circuit (CCN), installed at Nuclear Engineering Institute/CNEN. The thermo-hydraulic circuit comprises heater, heat exchanger, expansion tank, the pressure relief valve and pipes to interconnect the components. A glass tube is installed at the midpoint of the riser connected to the heater outlet. The natural circulation circuit is complemented by acquisition system of values of temperatures, flow and graphic interface. The instrumentation has thermocouples, volumetric flow meter, rotameter and high-speed digital camera. The experimental study is performed through analysis of information from measurements of temperatures at strategic points along the hydraulic circuit, besides natural circulation flow rates. The comparisons between analytical and experimental values are validated by viewing, recording and processing of the images for the flows patterns. Variables involved in the process of identification of flow regimes, dimensionless parameters, the phase velocity of the flow, initial boiling point, the phenomenon of 'flashing' pre-slug flow type were obtained experimentally. (author)

  19. Microstreaming from Sessile Semicylindrical Bubbles

    Science.gov (United States)

    Hilgenfeldt, Sascha; Rallabandi, Bhargav; Guo, Lin; Wang, Cheng

    2014-03-01

    Powerful steady streaming flows result from the ultrasonic driving of microbubbles, in particular when these bubbles have semicylindrical cross section and are positioned in contact with a microfluidic channel wall. We have used this streaming in experiment to develop novel methods for trapping and sorting of microparticles by size, as well as for micromixing. Theoretically, we arrive at an analytical description of the streaming flow field through an asymptotic computation that, for the first time, reconciles the boundary layers around the bubble and along the substrate wall, and also takes into account the oscillation modes of the bubble. This approach gives insight into changes in the streaming pattern with bubble size and driving frequency, including a reversal of the flow direction at high frequencies with potentially useful applications. Present address: Mechanical and Aerospace Engineering, Missouri S &T.

  20. Detailed modeling of hydrodynamics mass transfer and chemical reactions in a bubble column using a discrete bubble model

    NARCIS (Netherlands)

    Darmana, D.; Deen, N.G.; Kuipers, J.A.M.

    2005-01-01

    A 3D discrete bubble model is adopted to investigate complex behavior involving hydrodynamics, mass transfer and chemical reactions in a gas¿liquid bubble column reactor. In this model a continuum description is adopted for the liquid phase and additionally each individual bubble is tracked in a

  1. Numerical simulation of high Reynolds number bubble motion

    Energy Technology Data Exchange (ETDEWEB)

    McLaughlin, J.B. [Clarkson Univ., Potsdam, NY (United States)

    1995-12-31

    This paper presents the results of numerical simulations of bubble motion. All the results are for single bubbles in unbounded fluids. The liquid phase is quiescent except for the motion created by the bubble, which is axisymmetric. The main focus of the paper is on bubbles that are of order 1 mm in diameter in water. Of particular interest is the effect of surfactant molecules on bubble motion. Results for the {open_quotes}insoluble surfactant{close_quotes} model will be presented. These results extend research by other investigators to finite Reynolds numbers. The results indicate that, by assuming complete coverage of the bubble surface, one obtains good agreement with experimental observations of bubble motion in tap water. The effect of surfactant concentration on the separation angle is discussed.

  2. Sonochemistry and the acoustic bubble

    CERN Document Server

    Grieser, Franz; Enomoto, Naoya; Harada, Hisashi; Okitsu, Kenji; Yasui, Kyuichi

    2015-01-01

    Sonochemistry and the Acoustic Bubble provides an introduction to the way ultrasound acts on bubbles in a liquid to cause bubbles to collapse violently, leading to localized 'hot spots' in the liquid with temperatures of 5000° celcius and under pressures of several hundred atmospheres. These extreme conditions produce events such as the emission of light, sonoluminescence, with a lifetime of less than a nanosecond, and free radicals that can initiate a host of varied chemical reactions (sonochemistry) in the liquid, all at room temperature. The physics and chemistry behind the p

  3. Oscillation of large air bubble cloud

    International Nuclear Information System (INIS)

    Bae, Y.Y.; Kim, H.Y.; Park, J.K.

    2001-01-01

    The behavior of a large air bubble cloud, which is generated by the air discharged from a perforated sparger, is analyzed by solving Rayleigh-Plesset equation, energy equations and energy balance equation. The equations are solved by Runge-Kutta integration and MacCormack finite difference method. Initial conditions such as driving pressure, air volume, and void fraction strongly affect the bubble pressure amplitude and oscillation frequency. The pool temperature has a strong effect on the oscillation frequency and a negligible effect on the pressure amplitude. The polytropic constant during the compression and expansion processes of individual bubbles ranges from 1.0 to 1.4, which may be attributed to the fact that small bubbles oscillated in frequencies different from their resonance. The temperature of the bubble cloud rapidly approaches the ambient temperature, as is expected from the polytropic constants being between 1.0 and 1.4. (authors)

  4. Effect of supercritical water shell on cavitation bubble dynamics

    International Nuclear Information System (INIS)

    Shao Wei-Hang; Chen Wei-Zhong

    2015-01-01

    Based on reported experimental data, a new model for single cavitation bubble dynamics is proposed considering a supercritical water (SCW) shell surrounding the bubble. Theoretical investigations show that the SCW shell apparently slows down the oscillation of the bubble and cools the gas temperature inside the collapsing bubble. Furthermore, the model is simplified to a Rayleigh–Plesset-like equation for a thin SCW shell. The dependence of the bubble dynamics on the thickness and density of the SCW shell is studied. The results show the bubble dynamics depends on the thickness but is insensitive to the density of the SCW shell. The thicker the SCW shell is, the smaller are the wall velocity and the gas temperature in the bubble. In the authors’ opinion, the SCW shell works as a buffering agent. In collapsing, it is compressed to absorb a good deal of the work transformed into the bubble internal energy during bubble collapse so that it weakens the bubble oscillations. (paper)

  5. Oscillation of large air bubble cloud

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Y.Y.; Kim, H.Y.; Park, J.K. [Korea Atomic Energy Research Inst., Daejeon (Korea, Republic of)

    2001-07-01

    The behavior of a large air bubble cloud, which is generated by the air discharged from a perforated sparger, is analyzed by solving Rayleigh-Plesset equation, energy equations and energy balance equation. The equations are solved by Runge-Kutta integration and MacCormack finite difference method. Initial conditions such as driving pressure, air volume, and void fraction strongly affect the bubble pressure amplitude and oscillation frequency. The pool temperature has a strong effect on the oscillation frequency and a negligible effect on the pressure amplitude. The polytropic constant during the compression and expansion processes of individual bubbles ranges from 1.0 to 1.4, which may be attributed to the fact that small bubbles oscillated in frequencies different from their resonance. The temperature of the bubble cloud rapidly approaches the ambient temperature, as is expected from the polytropic constants being between 1.0 and 1.4. (authors)

  6. Structure and kinematics of bubble flow

    International Nuclear Information System (INIS)

    Lackme, C.

    1967-01-01

    This report deals with the components and use of resistivity probes in bubble flow. With a single probe, we have studied the longitudinal and radial structure of the flow. The very complicated evolution of the radial structure is shown by the measurement of the mean bubble flux at several points in the tube. A double probe associated with a device the principle of which is given in this report, permits the measure of the local velocity of bubbles. Unlike the mean bubble flux profile, the change in the velocity profile along the tube is not significant. We have achieved the synthesis of these two pieces of information, mean local bubble flux and local velocity, by computing the mean weighed velocity in the tube. This weighed velocity compares remarkably with the velocity computed from the volumetric gas flow rate and the mean void fraction. (author) [fr

  7. Universe out of a breathing bubble

    International Nuclear Information System (INIS)

    Guendelman, Eduardo I.; Sakai, Nobuyuki

    2008-01-01

    We consider the model of a false-vacuum bubble with a thin wall where the surface energy density is composed of two different components, 'domain-wall' type and 'dust' type, with opposite signs. We find stably oscillating solutions, which we call 'breathing bubbles'. By decay to a lower mass state, such a breathing bubble could become either (i) a child universe or ii) a bubble that 'eats up' the original universe, depending on the sign of the surface energy of the domain-wall component. We also discuss the effect of the finite-thickness corrections to the thin-wall approximation and possible origins of the energy contents of our model

  8. On Bubble Rising in Countercurrent Flow

    Czech Academy of Sciences Publication Activity Database

    Večeř, M.; Leštinský, P.; Wichterle, K.; Růžička, Marek

    2012-01-01

    Roč. 10, č. 2012 (2012), A30 ISSN 1542-6580 R&D Projects: GA ČR GA104/09/0972; GA ČR GA104/07/1110 Grant - others:GA MŠMT(CZ) CZ.1.05/2.1.00/03.0069 Institutional support: RVO:67985858 Keywords : ellipsoidal bubble * bubble shape * bubble velocity Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 0.790, year: 2011

  9. Shock waves from non-spherically collapsing cavitation bubbles

    Science.gov (United States)

    Supponen, Outi; Obreschkow, Danail; Farhat, Mohamed

    2017-11-01

    Combining simultaneous high-speed imaging and hydrophone measurements, we uncover details of the multiple shock wave emission from laser-induced cavitation bubbles collapsing in a non-spherical way. For strongly deformed bubbles collapsing near a free surface, we identify the distinct shock waves caused by the jet impact onto the opposite bubble wall and by the individual collapses of the remaining bubble segments. The energy carried by each of these shocks depends on the level of bubble deformation, quantified by the anisotropy parameter ζ, the dimensionless equivalent of the Kelvin impulse. For jetting bubbles, at ζ water hammer as ph = 0.45 (ρc2 Δp) 1 / 2ζ-1 .

  10. Human cerebral venous outflow pathway depends on posture and central venous pressure

    Science.gov (United States)

    Gisolf, J; van Lieshout, J J; van Heusden, K; Pott, F; Stok, W J; Karemaker, J M

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position, but mainly through the vertebral plexus in the upright position. A Valsalva manoeuvre while standing completely re-opened the jugular veins. Results of ultrasound imaging of the right internal jugular vein cross-sectional area at the level of the laryngeal prominence in six healthy subjects, before and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R2 = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway. The internal jugular veins are collapsed in the standing position and blood is shunted to an alternative venous pathway, but a marked increase in CVP while standing completely re-opens the jugular veins. PMID:15284348

  11. Penile venous surgery for treating erectile dysfunction: Past, present, and future perspectives with regard to new insights in venous anatomy

    Directory of Open Access Journals (Sweden)

    Cheng-Hsing Hsieh

    2016-06-01

    Full Text Available In the physiologic model of normal erectile function, a healthy veno-occlusive mechanism is essential to initiate and maintain a rigid erection. The surgical treatment of patients with venous leakage, which is synonymous with corporoveno-occlusive dysfunction (CVOD, was based on the decreased venous outflow during the erection process. The initial reports of short-term results were promising, but the long-term benefits of penile venous ligation surgery were limited. Most clinical guideline panels concluded that surgeries performed in an attempt to limit the venous outflow of the penis were not recommended. Consequently, this surgery was nearly abandoned in most medical societies worldwide. These unfavorable postoperative outcomes seemed attributable to the indispensable usage of electrocautery and insufficient venous management, based on conventional penile venous anatomy. Advances in better understanding of human penile venous anatomy has enabled the development of refined penile venous stripping surgery. The thorough stripping surgery is an even more radical procedure, which is an even more radical procedure, and seems to be a viable option for the treatment of CVOD, however, there is still a need for further study with well-defined diagnostic criteria, and standardized patient and partner outcome assessment.

  12. Formation of soap bubbles by gas jet

    OpenAIRE

    Zhou, M. L.; Li, M.; Chen, Z. Y.; Han, J. F.; Liu, D.

    2017-01-01

    Soap bubbles can be easily generated by varies methods, while their formation process is complicated and still worth study. A model about the bubble formation process was proposed in Phys. Rev. Lett. 116, 077801 recently, and it was reported that the bubbles were formed when the gas blowing velocity was above one threshold. However, after repeating these experiments, we found the bubbles could be generated in two velocities ranges which corresponded to laminar and turbulent gas jet respective...

  13. Formation of soap bubbles by gas jet

    Science.gov (United States)

    Zhou, Maolei; Li, Min; Chen, Zhiyuan; Han, Jifeng; Liu, Dong

    2017-12-01

    Soap bubbles can be easily generated by various methods, while their formation process is complicated and still worth studying. A model about the bubble formation process was proposed in the study by Salkin et al. [Phys. Rev. Lett. 116, 077801 (2016)] recently, and it was reported that the bubbles were formed when the gas blowing velocity was above one threshold. However, after a detailed study of these experiments, we found that the bubbles could be generated in two velocity ranges which corresponded to the laminar and turbulent gas jet, respectively, and the predicted threshold was only effective for turbulent gas flow. The study revealed that the bubble formation was greatly influenced by the aerodynamics of the gas jet blowing to the film, and these results will help to further understand the formation mechanism of the soap bubble as well as the interaction between the gas jet and the thin liquid film.

  14. Mechanism of bubble detachment from vibrating walls

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dongjun; Park, Jun Kwon, E-mail: junkeun@postech.ac.kr; Kang, Kwan Hyoung [Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), San 31, Hyoja-dong, Pohang 790-784 (Korea, Republic of); Kang, In Seok [Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), San 31, Hyoja-dong, Pohang 790-784 (Korea, Republic of)

    2013-11-15

    We discovered a previously unobserved mechanism by which air bubbles detach from vibrating walls in glasses containing water. Chaotic oscillation and subsequent water jets appeared when a wall vibrated at greater than a critical level. Wave forms were developed at water-air interface of the bubble by the wall vibration, and water jets were formed when sufficiently grown wave-curvatures were collapsing. Droplets were pinched off from the tip of jets and fell to the surface of the glass. When the solid-air interface at the bubble-wall attachment point was completely covered with water, the bubble detached from the wall. The water jets were mainly generated by subharmonic waves and were generated most vigorously when the wall vibrated at the volume resonant frequency of the bubble. Bubbles of specific size can be removed by adjusting the frequency of the wall's vibration.

  15. Cerebral venous outflow and cerebrospinal fluid dynamics

    Directory of Open Access Journals (Sweden)

    Clive B. Beggs

    2014-12-01

    Full Text Available In this review, the impact of restricted cerebral venous outflow on the biomechanics of the intracranial fluid system is investigated. The cerebral venous drainage system is often viewed simply as a series of collecting vessels channeling blood back to the heart. However there is growing evidence that it plays an important role in regulating the intracranial fluid system. In particular, there appears to be a link between increased cerebrospinal fluid (CSF pulsatility in the Aqueduct of Sylvius and constricted venous outflow. Constricted venous outflow also appears to inhibit absorption of CSF into the superior sagittal sinus. The compliance of the cortical bridging veins appears to be critical to the behaviour of the intracranial fluid system, with abnormalities at this location implicated in normal pressure hydrocephalus. The compliance associated with these vessels appears to be functional in nature and dependent on the free egress of blood out of the cranium via the extracranial venous drainage pathways. Because constricted venous outflow appears to be linked with increased aqueductal CSF pulsatility, it suggests that inhibited venous blood outflow may be altering the compliance of the cortical bridging veins.

  16. Three-dimensional one-way bubble tracking method for the prediction of developing bubble-slug flows in a vertical pipe. 1st report, models and demonstration

    International Nuclear Information System (INIS)

    Tamai, Hidesada; Tomiyama, Akio

    2004-01-01

    A three-dimensional one-way bubble tracking method is one of the most promising numerical methods for the prediction of a developing bubble flow in a vertical pipe, provided that several constitutive models are prepared. In this study, a bubble shape, an equation of bubble motion, a liquid velocity profile, a pressure field, turbulent fluctuation and bubble coalescence are modeled based on available knowledge on bubble dynamics. Bubble shapes are classified into four types in terms of bubble equivalent diameter. A wake velocity model is introduced to simulate approaching process among bubbles due to wake entrainment. Bubble coalescence is treated as a stochastic phenomenon with the aid of coalescence probabilities that depend on the sizes of two interacting bubbles. The proposed method can predict time-spatial evolution of flow pattern in a developing bubble-slug flow. (author)

  17. Effects of Gas Dynamics on Rapidly Collapsing Bubbles

    OpenAIRE

    Bauman, Spenser; Fomitchev-Zamilov, Max

    2013-01-01

    The dynamics of rapidly collapsing bubbles are of great interest due to the high degree of energy focusing that occurs withing the bubble. Molecular dynamics provides a way to model the interior of the bubble and couple the gas dynamics with the equations governing the bubble wall. While much theoretical work has been done to understand how a bubble will respond to an external force, the internal dynamics of the gas system are usually simplified greatly in such treatments. This paper shows ho...

  18. Simple improvements to classical bubble nucleation models.

    Science.gov (United States)

    Tanaka, Kyoko K; Tanaka, Hidekazu; Angélil, Raymond; Diemand, Jürg

    2015-08-01

    We revisit classical nucleation theory (CNT) for the homogeneous bubble nucleation rate and improve the classical formula using a correct prefactor in the nucleation rate. Most of the previous theoretical studies have used the constant prefactor determined by the bubble growth due to the evaporation process from the bubble surface. However, the growth of bubbles is also regulated by the thermal conduction, the viscosity, and the inertia of liquid motion. These effects can decrease the prefactor significantly, especially when the liquid pressure is much smaller than the equilibrium one. The deviation in the nucleation rate between the improved formula and the CNT can be as large as several orders of magnitude. Our improved, accurate prefactor and recent advances in molecular dynamics simulations and laboratory experiments for argon bubble nucleation enable us to precisely constrain the free energy barrier for bubble nucleation. Assuming the correction to the CNT free energy is of the functional form suggested by Tolman, the precise evaluations of the free energy barriers suggest the Tolman length is ≃0.3σ independently of the temperature for argon bubble nucleation, where σ is the unit length of the Lennard-Jones potential. With this Tolman correction and our prefactor one gets accurate bubble nucleation rate predictions in the parameter range probed by current experiments and molecular dynamics simulations.

  19. Sonoluminescing Air Bubbles Rectify Argon

    NARCIS (Netherlands)

    Lohse, Detlef; Brenner, Michael P.; Dupont, Todd F.; Hilgenfeldt, Sascha; Johnston, Blaine

    1997-01-01

    The dynamics of single bubble sonoluminescence (SBSL) strongly depends on the percentage of inert gas within the bubble. We propose a theory for this dependence, based on a combination of principles from sonochemistry and hydrodynamic stability. The nitrogen and oxygen dissociation and subsequent

  20. A note on effects of rational bubble on portfolios

    Science.gov (United States)

    Wang, Chan; Nie, Pu-yan

    2018-02-01

    In general, demand increases in wealth and decreases in price in microeconomics. We thereby propose a completely different perspective. By establishing expected utility function of investors, this article introduces one rational bubble asset and one bubble free asset in portfolios and focuses on the effects of bubble on investment portfolios from wealth and price perspectives. All conclusions are obtained by theoretical analysis with microeconomics theory. We argue that inferior goods and Giffen behavior can occur for the bubble free asset in microeconomic fields. The results can help investors to recognize bubble assets and bubble free assets more scientifically. Both bubble and bubble free assets can be inferior goods under some conditions, so we cannot to say which asset better than the other one absolutely.

  1. Chronic venous disease.

    Science.gov (United States)

    Wolinsky, Claire D; Waldorf, Heidi

    2009-11-01

    Identifying characteristic cutaneous findings is important in determining the appropriate management of certain venous diseases. The health care provider should be familiar with the classic description of patterns and distributions of skin manifestations, such as varicose veins, stasis dermatitis, palpable cord, petechiae, and telangiectasias. In addition to the gross appearance of the skin, a skin biopsy may help elucidate a diagnosis. General treatment and prevention of the underlying venous pathology is essential. Furthermore, specific management of skin findings should include therapy to ameliorate progression of disease and symptomatology when warranted.

  2. Central Venous Access

    International Nuclear Information System (INIS)

    Ganeshan, Arul; Warakaulle, Dinuke R.; Uberoi, Raman

    2007-01-01

    Central venous access plays an important role in the management of an ever-increasing population of patients ranging from those that are critically ill to patients with difficult clinical access. Interventional radiologists are key in delivering this service and should be familiar with the wide range of techniques and catheters now available to them. A comprehensive description of these catheters with regard to indications, technical aspects of catheterization, success rates, and associated early and late complications, as well as a review of various published guidelines on central venous catheter insertion are given in this article

  3. Bubble fusion: Preliminary estimates

    International Nuclear Information System (INIS)

    Krakowski, R.A.

    1995-01-01

    The collapse of a gas-filled bubble in disequilibrium (i.e., internal pressure much-lt external pressure) can occur with a significant focusing of energy onto the entrapped gas in the form of pressure-volume work and/or acoustical shocks; the resulting heating can be sufficient to cause ionization and the emission of atomic radiations. The suggestion that extreme conditions necessary for thermonuclear fusion to occur may be possible has been examined parametrically in terms of the ratio of initial bubble pressure relative to that required for equilibrium. In this sense, the disequilibrium bubble is viewed as a three-dimensional ''sling shot'' that is ''loaded'' to an extent allowed by the maximum level of disequilibrium that can stably be achieved. Values of this disequilibrium ratio in the range 10 -5 --10 -6 are predicted by an idealized bubble-dynamics model as necessary to achieve conditions where nuclear fusion of deuterium-tritium might be observed. Harmonic and aharmonic pressurizations/decompressions are examined as means to achieve the required levels of disequilibrium required to create fusion conditions. A number of phenomena not included in the analysis reported herein could enhance or reduce the small levels of nuclear fusions predicted

  4. From Rising Bubble to RNA/DNA and Bacteria

    Science.gov (United States)

    Marks, Roman; Cieszyńska, Agata; Wereszka, Marzena; Borkowski, Wojciech

    2017-04-01

    In this study we have focused on the movement of rising bubbles in a salty water body. Experiments reviled that free buoyancy movement of bubbles forces displacement of ions, located on the outer side of the bubble wall curvatures. During the short moment of bubble passage, all ions in the vicinity of rising bubble, are separated into anions that are gathered on the bubble upper half sphere and cations that slip along the bottom concave half-sphere of a bubble and develop a sub-bubble vortex. The principle of ions separation bases on the differences in displacement resistance. In this way, relatively heavier and larger, thus more resistant to displacement anions are gathered on the rising bubble upper half sphere, while smaller and lighter cations are assembled on the bottom half sphere and within the sub-bubble vortex. The acceleration of motion generates antiparallel rotary of bi-ionic domains, what implies that anions rotate in clockwise (CW) and cationic in counter-clockwise (CCW) direction. Then, both rotational systems may undergo splicing and extreme condensing by bi-pirouette narrowing of rotary. It is suggested that such double helix motion of bi-ionic domains creates RNA/DNA molecules. Finally, when the bubble reaches the water surface it burst and the preprocessed RNA/DNA matter is ejected into the droplets. Since that stage, droplet is suspended in positively charged troposphere, thus the cationic domain is located in the droplet center, whilst negative ions are attracted to configure the outer areola. According to above, the present study implies that the rising bubbles in salty waters may incept synergistic processing of matter resulting in its rotational/spherical organization that led to assembly of RNA/DNA molecules and bacteria cells.

  5. Application of coalescence and breakup models in a discrete bubble model for bubble columns

    NARCIS (Netherlands)

    van den Hengel, E.I.V.; Deen, N.G.; Kuipers, J.A.M.

    2005-01-01

    In this work, a discrete bubble model (DBM) is used to investigate the hydrodynamics, coalescence, and breakup occurring in a bubble column. The DBM, originally developed by Delnoij et al. (Chem. Eng. Sci. 1997, 52, 1429-1458; Chem. Eng. Sci. 1999, 54, 2217-2226),1,2 was extended to incorporate

  6. Sonar gas flux estimation by bubble insonification: application to methane bubble flux from seep areas in the outer Laptev Sea

    Science.gov (United States)

    Leifer, Ira; Chernykh, Denis; Shakhova, Natalia; Semiletov, Igor

    2017-06-01

    Sonar surveys provide an effective mechanism for mapping seabed methane flux emissions, with Arctic submerged permafrost seepage having great potential to significantly affect climate. We created in situ engineered bubble plumes from 40 m depth with fluxes spanning 0.019 to 1.1 L s-1 to derive the in situ calibration curve (Q(σ)). These nonlinear curves related flux (Q) to sonar return (σ) for a multibeam echosounder (MBES) and a single-beam echosounder (SBES) for a range of depths. The analysis demonstrated significant multiple bubble acoustic scattering - precluding the use of a theoretical approach to derive Q(σ) from the product of the bubble σ(r) and the bubble size distribution where r is bubble radius. The bubble plume σ occurrence probability distribution function (Ψ(σ)) with respect to Q found Ψ(σ) for weak σ well described by a power law that likely correlated with small-bubble dispersion and was strongly depth dependent. Ψ(σ) for strong σ was largely depth independent, consistent with bubble plume behavior where large bubbles in a plume remain in a focused core. Ψ(σ) was bimodal for all but the weakest plumes. Q(σ) was applied to sonar observations of natural arctic Laptev Sea seepage after accounting for volumetric change with numerical bubble plume simulations. Simulations addressed different depths and gases between calibration and seep plumes. Total mass fluxes (Qm) were 5.56, 42.73, and 4.88 mmol s-1 for MBES data with good to reasonable agreement (4-37 %) between the SBES and MBES systems. The seepage flux occurrence probability distribution function (Ψ(Q)) was bimodal, with weak Ψ(Q) in each seep area well described by a power law, suggesting primarily minor bubble plumes. The seepage-mapped spatial patterns suggested subsurface geologic control attributing methane fluxes to the current state of subsea permafrost.

  7. Radiologically-placed venous ports in children under venous anesthesia

    International Nuclear Information System (INIS)

    Jang, Joo Yeon; Jeon, Ung Bae; Choo, Ki Seok; Hwang, Jae Yeon; Kim, Yong Woo; Lee, Yun Jin; Nam, Sang Ool; Lim, Young Tak

    2015-01-01

    To evaluate the efficacy and safety of radiologic venous port placement in children under venous anesthesia. Between April 2009 and July 2011, 44 ports were implanted in 41 children (24 boys, 17 girls). The age of patients ranged from 9 months to 19 years (mean, 6.5 years) and their body weights ranged from 6.8 kg to 56.3 kg (mean, 23.2 kg). Right internal jugular vein access was used in 42 ports, right subclavian vein in 1, and left subclavian in 1. Durability and complications of port implantation were reviewed. The technical success rate was 100%. The catheter life was 10-661 days (mean 246 days). Two patients died during the follow-up period, 21 and 6 ports were removed at the end of treatment or as a result of complications, respectively. One port was removed and replaced by a Hickmann catheter. Three ports were explanted due to port-related sepsis, one due to a catheter kink, and two for unexplained fever or insertion site pain. The overall port-related infection was 3 cases (6.8%, 0.28/1000 catheter days). Venous port placement by interventional radiologists in children under intravenous sedation is relatively safe, with a high rate of technical success and low rate of complications.

  8. Radiologically-placed venous ports in children under venous anesthesia

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Joo Yeon; Jeon, Ung Bae; Choo, Ki Seok; Hwang, Jae Yeon; Kim, Yong Woo; Lee, Yun Jin; Nam, Sang Ool; Lim, Young Tak [Pusan National University School of Medicine, Yangsan (Korea, Republic of)

    2015-02-15

    To evaluate the efficacy and safety of radiologic venous port placement in children under venous anesthesia. Between April 2009 and July 2011, 44 ports were implanted in 41 children (24 boys, 17 girls). The age of patients ranged from 9 months to 19 years (mean, 6.5 years) and their body weights ranged from 6.8 kg to 56.3 kg (mean, 23.2 kg). Right internal jugular vein access was used in 42 ports, right subclavian vein in 1, and left subclavian in 1. Durability and complications of port implantation were reviewed. The technical success rate was 100%. The catheter life was 10-661 days (mean 246 days). Two patients died during the follow-up period, 21 and 6 ports were removed at the end of treatment or as a result of complications, respectively. One port was removed and replaced by a Hickmann catheter. Three ports were explanted due to port-related sepsis, one due to a catheter kink, and two for unexplained fever or insertion site pain. The overall port-related infection was 3 cases (6.8%, 0.28/1000 catheter days). Venous port placement by interventional radiologists in children under intravenous sedation is relatively safe, with a high rate of technical success and low rate of complications.

  9. Theoretical aspects of appearing of bubbles in economy

    Directory of Open Access Journals (Sweden)

    Pronoza Pavlo V.

    2014-01-01

    Full Text Available The article considers theoretical aspects of appearing of bubbles in economy. It analyses vies of scientists regarding the essence of this phenomenon and, with the help of content analysis, specifies the essence of the bubble notion in economy. It considers main stages of appearance of such bubbles. It offers classification of their types. It analyses pre-requisites of appearance of bubbles in economy and their features. It considers main existing approaches to detection and modelling appearance of bubbles. It proves that bubbles negatively influence economy of the countries, that is why, the problem of their detection and prevention is one of the central problems in the process of development of policy of state regulation of economy.

  10. A review of studies of the proteomes of circulating microparticles

    DEFF Research Database (Denmark)

    Nielsen, Christoffer Tandrup; Østergaard, Ole; Rasmussen, Niclas S

    2017-01-01

    of the specific proteins and their quantities, i.e. the proteome, in complex samples such as MPs enables an in-depth characterization of the phenotypical changes of the MPs during disease states. At present, only a limited number of proteomic studies of circulating MPs have been carried out in healthy individuals...... and disease populations. Interestingly, these studies indicate that a small set of MP-proteins, in particular, overexpression of galectin-3-binding protein (G3BP) distinguish MPs in patients with venous thromboembolism and the systemic autoimmune disease, systemic lupus erythematosus (SLE). G3BP is important...

  11. Gas transfer in a bubbly wake flow

    Science.gov (United States)

    Karn, A.; Gulliver, J. S.; Monson, G. M.; Ellis, C.; Arndt, R. E. A.; Hong, J.

    2016-05-01

    The present work reports simultaneous bubble size and gas transfer measurements in a bubbly wake flow of a hydrofoil, designed to be similar to a hydroturbine blade. Bubble size was measured by a shadow imaging technique and found to have a Sauter mean diameter of 0.9 mm for a reference case. A lower gas flow rate, greater liquid velocities, and a larger angle of attack all resulted in an increased number of small size bubbles and a reduced weighted mean bubble size. Bubble-water gas transfer is measured by the disturbed equilibrium technique. The gas transfer model of Azbel (1981) is utilized to characterize the liquid film coefficient for gas transfer, with one scaling coefficient to reflect the fact that characteristic turbulent velocity is replaced by cross-sectional mean velocity. The coefficient was found to stay constant at a particular hydrofoil configuration while it varied within a narrow range of 0.52-0.60 for different gas/water flow conditions.

  12. The KEK 1 m hydrogen bubble chamber

    International Nuclear Information System (INIS)

    Doi, Yoshikuni; Araoka, Osamu; Hayashi, Kohei; Hayashi, Yoshio; Hirabayashi, Hiromi.

    1978-03-01

    A medium size hydrogen bubble chamber has been constructed at the National Laboratory for High Energy Physics, KEK. The bubble chamber has been designed to be operated with a maximum rate of three times per half a second in every two second repetition time of the accelerator, by utilizing a hydraulic expansion system. The bubble chamber has a one meter diameter and a visible volume of about 280 l. A three-view stereo camera system is used for taking photographic pictures of the chamber. A 2 MW bubble chamber magnet is constructed. The main part of the bubble chamber vessel is supported by the magnet yoke. The magnet gives a maximum field of 18.4 kG at the centre of the fiducial volume of the chamber. The overall system of the KEK 1 m hydrogen bubble chamber facility is described in some detail. Some operational characteristics of the facility are also reported. (auth.)

  13. The little holographic bubble chambers

    International Nuclear Information System (INIS)

    Herve, A.

    1983-01-01

    The lifetime study of the charmed particles has readvanced the idea to use holography for the little fast-cycle bubble chambers. A pilot experiment has been realised in 1982 with a little bubble chamber filled up with freon-115. 40000 holograms have been recorded [fr

  14. Gas fluxing of aluminum: a bubble probe for optimization of bubbles/bubble distribution and minimization of splashing/droplet formation

    International Nuclear Information System (INIS)

    James W. Evans; Auitumn Fjeld

    2006-01-01

    Aluminum is one of our most important materials and finds major use in transportation (e.g. aircraft) and packaging (e.g. beverage cans). According to International Aluminium Institute statistics (www.world-aluminium.org) 23.46 million metric tons of aluminum were produced last year in the electrolytic cells used to make this metal, continuing an increase seen over the previous four years and sustained for the first half of this year. 23% of this ?primary? production was in North America. A smaller, yet important, source of the nation?s aluminum is ''secondary production'', that is the recycling of aluminum products such as beverage cans. The Aluminum Association reports that 51.4 billion beverage cans were recycled in the U.S. last year (compared to 98.9 billion new cans shipped). Whether from primary or secondary production, it is typically necessary to treat the aluminum to remove small quantities of impurities or unwanted alloying agents before the metal can be further processed and sold. In the case of primary aluminum it is the removal of trace impurities such as sodium that is needed; in the case of recycled aluminum it is the removal of alloy constituents, such as magnesium which is, after aluminum, the principal metal used in beverage cans. The procedure commonly used is known as ''gas fluxing'' and entails bubbling a reactive mixture of chlorine and argon through the molten metal. The intent is that the chlorine react with the impurities to form compounds that can easily separate from the aluminum. Unfortunately a fraction of the chlorine forms volatile aluminum chloride that leaves the fluxing unit. This represents a loss of aluminum product; furthermore the aluminum chloride can react with atmospheric moisture to form hydrogen chloride gas with impact on workers and the environment. Some of these emissions are controlled by bag houses but some escape. For example EPA's Toxic Release Inventory for 1997 has stack emissions of chlorides and chlorine

  15. Interaction of equal-size bubbles in shear flow.

    Science.gov (United States)

    Prakash, Jai; Lavrenteva, Olga M; Byk, Leonid; Nir, Avinoam

    2013-04-01

    The inertia-induced forces on two identical spherical bubbles in a simple shear flow at small but finite Reynolds number, for the case when the bubbles are within each other's inner viscous region, are calculated making use of the reciprocal theorem. This interaction force is further employed to model the dynamics of air bubbles injected to a viscous fluid sheared in a Couette device at the first shear flow instability where the bubbles are trapped inside the stable Taylor vortex. It was shown that, during a long time scale, the inertial interaction between the bubbles in the primary shear flow drives them away from each other and, as a result, equal-size bubbles eventually assume an ordered string with equal separation distances between all neighbors. We report on experiments showing the dynamic evolution of various numbers of bubbles. The results of the theory are in good agreement with the experimental observations.

  16. Comparison of cavitation bubbles evolution in viscous media

    Directory of Open Access Journals (Sweden)

    Jasikova Darina

    2018-01-01

    Full Text Available There have been tried many types of liquids with different ranges of viscosity values that have been tested to form a single cavitation bubble. The purpose of these experiments was to observe the behaviour of cavitation bubbles in media with different ranges of absorbance. The most of the method was based on spark to induced superheat limit of liquid. Here we used arrangement of the laser-induced breakdown (LIB method. There were described the set cavitation setting that affects the size bubble in media with different absorbance. We visualized the cavitation bubble with a 60 kHz high speed camera. We used here shadowgraphy setup for the bubble visualization. There were observed time development and bubble extinction in various media, where the size of the bubble in the silicone oil was extremely small, due to the absorbance size of silicon oil.

  17. Shock formation within sonoluminescence bubbles

    International Nuclear Information System (INIS)

    Vuong, V.Q.; Szeri, A.J.; Young, D.A.

    1999-01-01

    A strong case has been made by several authors that sharp, spherically symmetric shocks converging on the center of a spherical bubble driven by a strong acoustic field give rise to rapid compression and heating that produces the brief flash of light known as sonoluminescence. The formation of such shocks is considered. It is found that, although at the main collapse the bubble wall does indeed launch an inwardly-traveling compression wave, and although the subsequent reflection of the wave at the bubble center produces a very rapid temperature peak, the wave is prevented from steepening into a sharp shock by an adverse gradient in the sound speed caused by heat transfer. It is shown that the mathematical characteristics of the flow can be prevented from accumulating into a shock front by this adverse sound speed gradient. A range of results is presented for a variety of bubble ambient radii and sound field amplitudes suggested by experiments. The time scale of the peak temperature in the bubble is set by the dynamics of the compression wave: this is typically in the range 100 - 300 ps (FWHM) in concert with recent measurements of the sonoluminescence pulse width. copyright 1999 American Institute of Physics

  18. Dynamics of bubble formation in highly viscous liquids.

    Science.gov (United States)

    Pancholi, Ketan; Stride, Eleanor; Edirisinghe, Mohan

    2008-04-15

    There has recently been considerable interest in the development of devices for the preparation of monodisperse microbubble suspensions for use as ultrasound contrast agents and drug delivery vehicles. These applications require not only a high degree of bubble uniformity but also a maximum bubble size of 8 mum, and this provides a strong motivation for developing an improved understanding of the process of bubble formation in a given device. The aim of this work was to investigate bubble formation in a T-junction device and determine the influence of the different processing parameters upon bubble size, in particular, liquid viscosity. Images of air bubble formation in a specially designed T-junction were recorded using a high-speed camera for different ratios of liquid to gas flow rate (Ql/Qg) and different liquid viscosities (microl). It was found that theoretical predictions of the flow profile in the focal region based on analysis of axisymmetric Stokes flow were accurate to within 6% when compared with the experimental data, indicating that this provided a suitable means of describing the bubble formation process. Both the theoretical and experimental results showed that Ql/Qg and mul had a significant influence upon bubble formation and eventual size, with higher flow rates and higher viscosities producing smaller bubbles. There were, however, found to be limiting values of Ql/Qg and mul beyond which no further reduction in bubble size was achieved.

  19. Venous thromboembolism and arterial complications.

    Science.gov (United States)

    Prandoni, Paolo; Piovella, Chiara; Pesavento, Raffaele

    2012-04-01

    An increasing body of evidence suggests the likelihood of a link between venous and arterial thrombosis. The two vascular complications share several risk factors, such as age, obesity, smoking, diabetes mellitus, blood hypertension, hypertriglyceridemia, and metabolic syndrome. Moreover, there are many examples of conditions accounting for both venous and arterial thrombosis, such as the antiphospholipid antibody syndrome, hyperhomocysteinemia, malignancies, infections, and the use of hormonal treatment. Finally, several recent studies have consistently shown that patients with venous thromboembolism are at a higher risk of arterial thrombotic complications than matched control individuals. We, therefore, speculate the two vascular complications are simultaneously triggered by biological stimuli responsible for activating coagulation and inflammatory pathways in both the arterial and the venous system. Future studies are needed to clarify the nature of this association, to assess its extent, and to evaluate its implications for clinical practice. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  20. Dynamics of micro-bubble sonication inside a phantom vessel

    KAUST Repository

    Qamar, Adnan; Samtaney, Ravi; Bull, Joseph L.

    2013-01-01

    A model for sonicated micro-bubble oscillations inside a phantom vessel is proposed. The model is not a variant of conventional Rayleigh-Plesset equation and is obtained from reduced Navier-Stokes equations. The model relates the micro-bubble oscillation dynamics with geometric and acoustic parameters in a consistent manner. It predicts micro-bubble oscillation dynamics as well as micro-bubble fragmentation when compared to the experimental data. For large micro-bubble radius to vessel diameter ratios, predictions are damped, suggesting breakdown of inherent modeling assumptions for these cases. Micro-bubble response with acoustic parameters is consistent with experiments and provides physical insight to the micro-bubble oscillation dynamics.

  1. Dynamics of micro-bubble sonication inside a phantom vessel

    KAUST Repository

    Qamar, Adnan

    2013-01-10

    A model for sonicated micro-bubble oscillations inside a phantom vessel is proposed. The model is not a variant of conventional Rayleigh-Plesset equation and is obtained from reduced Navier-Stokes equations. The model relates the micro-bubble oscillation dynamics with geometric and acoustic parameters in a consistent manner. It predicts micro-bubble oscillation dynamics as well as micro-bubble fragmentation when compared to the experimental data. For large micro-bubble radius to vessel diameter ratios, predictions are damped, suggesting breakdown of inherent modeling assumptions for these cases. Micro-bubble response with acoustic parameters is consistent with experiments and provides physical insight to the micro-bubble oscillation dynamics.

  2. IMPLEMENTATION OF SERIAL AND PARALLEL BUBBLE SORT ON FPGA

    Directory of Open Access Journals (Sweden)

    Dwi Marhaendro Jati Purnomo

    2016-06-01

    Full Text Available Sorting is common process in computational world. Its utilization are on many fields from research to industry. There are many sorting algorithm in nowadays. One of the simplest yet powerful is bubble sort. In this study, bubble sort is implemented on FPGA. The implementation was taken on serial and parallel approach. Serial and parallel bubble sort then compared by means of its memory, execution time, and utility which comprises slices and LUTs. The experiments show that serial bubble sort required smaller memory as well as utility compared to parallel bubble sort. Meanwhile, parallel bubble sort performed faster than serial bubble sort

  3. Venous trauma in the Lebanon War--2006.

    Science.gov (United States)

    Nitecki, Samy S; Karram, Tony; Hoffman, Aaron; Bass, Arie

    2007-10-01

    Reports on venous trauma are relatively sparse. Severe venous trauma is manifested by hemorrhage, not ischemia. Bleeding may be internal or external and rarely may lead to hypovolemic shock. Repair of major extremity veins has been a subject of controversy and the current teaching is to avoid venous repair in an unstable or multi-trauma patient. The aim of the current paper is to present our recent experience in major venous trauma during the Lebanon conflict, means of diagnosis and treatment in a level I trauma center. All cases of major venous trauma, either isolated or combined with arterial injury, admitted to the emergency room during the 33-day conflict were reviewed. Out of 511 wounded soldiers and civilians who were admitted to our service over this period, 12 (2.3%) sustained a penetrating venous injury either isolated (5) or combined with arterial injury (7). All injuries were secondary to high velocity penetrating missiles or from multiple pellets stored in long-range missiles. All injuries were accompanied by additional insult to soft tissue, bone and viscera. The mean injury severity score was 15. Severe external bleeding was the presenting symptom in three cases of isolated venous injury (jugular, popliteal and femoral). The diagnosis of a major venous injury was made by a CTA scan in five cases, angiography in one and during surgical exploration in six cases. All injured veins were repaired: three by venous interposition grafts, four by end to end anastomosis, three by lateral suture and two by endovascular techniques. None of the injuries was treated by ligation of a major named vein. Immediate postoperative course was uneventful in all patients and the 30-day follow-up (by clinical assessment and duplex scan) has demonstrated a patent repair with no evidence of thrombosis. Without contradicting the wisdom of ligating major veins in the setup of multi-trauma or an unstable patient, our experience indicates that a routine repair of venous trauma can

  4. Bubble gate for in-plane flow control.

    Science.gov (United States)

    Oskooei, Ali; Abolhasani, Milad; Günther, Axel

    2013-07-07

    We introduce a miniature gate valve as a readily implementable strategy for actively controlling the flow of liquids on-chip, within a footprint of less than one square millimetre. Bubble gates provide for simple, consistent and scalable control of liquid flow in microchannel networks, are compatible with different bulk microfabrication processes and substrate materials, and require neither electrodes nor moving parts. A bubble gate consists of two microchannel sections: a liquid-filled channel and a gas channel that intercepts the liquid channel to form a T-junction. The open or closed state of a bubble gate is determined by selecting between two distinct gas pressure levels: the lower level corresponds to the "open" state while the higher level corresponds to the "closed" state. During closure, a gas bubble penetrates from the gas channel into the liquid, flanked by a column of equidistantly spaced micropillars on each side, until the flow of liquid is completely obstructed. We fabricated bubble gates using single-layer soft lithographic and bulk silicon micromachining procedures and evaluated their performance with a combination of theory and experimentation. We assessed the dynamic behaviour during more than 300 open-and-close cycles and report the operating pressure envelope for different bubble gate configurations and for the working fluids: de-ionized water, ethanol and a biological buffer. We obtained excellent agreement between the experimentally determined bubble gate operational envelope and a theoretical prediction based on static wetting behaviour. We report case studies that serve to illustrate the utility of bubble gates for liquid sampling in single and multi-layer microfluidic devices. Scalability of our strategy was demonstrated by simultaneously addressing 128 bubble gates.

  5. Inertial collapse of bubble pairs near a solid surface

    Science.gov (United States)

    Alahyari Beig, Shahaboddin; Johnsen, Eric

    2017-11-01

    Cavitation occurs in a variety of applications ranging from naval structures to biomedical ultrasound. One important consequence is structural damage to neighboring surfaces following repeated inertial collapse of vapor bubbles. Although the mechanical loading produced by the collapse of a single bubble has been widely investigated, less is known about the detailed dynamics of the collapse of multiple bubbles. In such a problem, the bubble-bubble interactions typically affect the dynamics, e.g., by increasing the non-sphericity of the bubbles and amplifying/hindering the collapse intensity depending on the flow parameters. Here, we quantify the effects of bubble-bubble interactions on the bubble dynamics, as well as the pressures/temperatures produced by the collapse of a pair of gas bubbles near a rigid surface. We perform high-resolution simulations of this problem by solving the three-dimensional compressible Navier-Stokes equations for gas/liquid flows. The results are used to investigate the non-spherical bubble dynamics and characterize the pressure and temperature fields based on the relevant parameters entering the problem: stand-off distance, geometrical configuration (angle, relative size, distance), collapse strength. This research was supported in part by ONR Grant N00014-12-1-0751 and NSF Grant CBET 1253157.

  6. Venous infraction of developmental venous anomaly: A case report with perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Youn; Kim, Hye Jeong; Hyun, Su Jeong; Kim, Hee Yeong; Kim, Han Myun; Hwang, Ji Young; Hong, Hye Suk; Woo, Ji Young; Yang, Ik [Dept. of Radiology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of); Kim, Eun Soo [Dept. of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of)

    2017-06-15

    Developmental venous anomaly (DVA) is a common congenital venous malformation characterized by dilated medullary veins in caput medusa configuration and a draining vein. Despite the high incidence of DVAs, they are benign anatomic variations and rarely cause symptoms. Here, we report computed tomography and magnetic resonance imaging findings with perfusion images of acute infarction from underlying DVA in a 63-year-old female patient who presented with acute onset of neurologic symptoms and recovered without any neurologic deficit.

  7. Human cerebral venous outflow pathway depends on posture and central venous pressure

    DEFF Research Database (Denmark)

    Gisolf, J; van Lieshout, J J; van Heusden, K

    2004-01-01

    and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest......Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture...... and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position...

  8. Local measurements in turbulent bubbly flows

    International Nuclear Information System (INIS)

    Suzanne, C.; Ellingsen, K.; Risso, F.; Roig, V.

    1998-01-01

    Local measurements methods in bubbly flows are discussed. Concerning liquid velocity measurement, problems linked to HFA and LDA are first analysed. Then simultaneously recorded velocity signals obtained by both anemometers are compared. New signal processing are developed for the two techniques. Bubble sizes and velocities measurements methods using intrusive double optical sensor probe are presented. Plane bubbly mixing layer has been investigated. Local measurements using the described methods are presented as examples. (author)

  9. Bursting the bubble of melt inclusions

    Science.gov (United States)

    Lowenstern, Jacob B.

    2015-01-01

    Most silicate melt inclusions (MI) contain bubbles, whose significance has been alternately calculated, pondered, and ignored, but rarely if ever directly explored. Moore et al. (2015) analyze the bubbles, as well as their host glasses, and conclude that they often hold the preponderance of CO2 in the MI. Their findings entreat future researchers to account for the presence of bubbles in MI when calculating volatile budgets, saturation pressures, and eruptive flux.

  10. Fast Initialization of Bubble-Memory Systems

    Science.gov (United States)

    Looney, K. T.; Nichols, C. D.; Hayes, P. J.

    1986-01-01

    Improved scheme several orders of magnitude faster than normal initialization scheme. State-of-the-art commercial bubble-memory device used. Hardware interface designed connects controlling microprocessor to bubblememory circuitry. System software written to exercise various functions of bubble-memory system in comparison made between normal and fast techniques. Future implementations of approach utilize E2PROM (electrically-erasable programable read-only memory) to provide greater system flexibility. Fastinitialization technique applicable to all bubble-memory devices.

  11. Investigation of the condensing vapor bubble behavior through CFD simulation

    International Nuclear Information System (INIS)

    Sablania, Sidharth; Verma, Akash; Goyal, P.; Dutta, Anu; Singh, R.K.

    2013-09-01

    In nuclear systems the sub-cooled boiling flow is an important problem due to the behavior of condensing vapor bubble which has a large effect on the heat transfer characteristics as well as pressure drops and flow instability. The sub-cooled boiling flows become very complex and dynamic phenomena by the vapor bubble-water interaction. This happens due to the boiling/condensation, break-up, and coalescence of the bubble and needs to be addressed for characterizing the above mentioned flow parameters. There have been many researches to analyze the behavior of bubble experimentally and analytically. However, it is very difficult to get complete information about the behavior of bubble because of ever changing interface between vapor and water phase due to bubble condensation/evaporation Therefore, it is necessary to carry out a CFD simulation for better understanding the complex phenomenon of the bubble behavior. The present work focuses on the simulation of condensing bubble in subcooled boiling flow using (Volume of Fluid) VOF method in the CFD code CFD-ACE+. In order to simulate the heat and mass transfer through the bubble interface, CFD modeling for the bubble condensation was developed by modeling the source terms in the governing equations of VOF model using the User-Defined Function (UDF) in CFD-ACE+ code. The effect of condensation on bubble behavior was analyzed by comparing the behavior of condensing bubble with that of adiabatic bubble. It was observed that the behavior of condensing bubble was different from that of non condensing bubble in respect of bubble shape, diameter, velocity etc. The results obtained from the present simulation in terms of various parameters such as bubble velocity, interfacial area and bubble volume agreed well with the reported experimental results verified with FLUENT code in available literature. Hence, this CFD-ACE+ simulation of single bubble condensation will be a useful computational fluid dynamics tool for analyzing the

  12. Experimental investigation of shock wave - bubble interaction

    Energy Technology Data Exchange (ETDEWEB)

    Alizadeh, Mohsen

    2010-04-09

    In this work, the dynamics of laser-generated single cavitation bubbles exposed to lithotripter shock waves has been investigated experimentally. The energy of the impinging shock wave is varied in several steps. High-speed photography and pressure field measurements simultaneously with image acquisition provide the possibility of capturing the fast bubble dynamics under the effect of the shock wave impact. The pressure measurement is performed using a fiber optic probe hydrophone (FOPH) which operates based on optical diagnostics of the shock wave propagating medium. After a short introduction in chapter 1 an overview of the previous studies in chapter 2 is presented. The reported literatures include theoretical and experimental investigations of several configurations of physical problems in the field of bubble dynamics. In chapter 3 a theoretical description of propagation of a shock wave in a liquid like water has been discussed. Different kinds of reflection of a shock wave at an interface are taken into account. Undisturbed bubble dynamics as well as interaction between a planar shock wave and an initially spherical bubble are explored theoretically. Some physical parameters which are important in this issue such as the velocity of the shock-induced liquid jet, Kelvin impulse and kinetic energy are explained. The shock waves are generated in a water filled container by a focusing piezoelectric generator. The shock wave profile has a positive part with pulse duration of ∼1 μs followed by a longer tension tail (i.e. ∼3 μs). In chapter 4 high-speed images depict the propagation of a shock wave in the water filled tank. The maximum pressure is also derived for different intensity levels of the shock wave generator. The measurement is performed in the free field (i.e. in the absence of laser-generated single bubbles). In chapter 5 the interaction between lithotripter shock waves and laserinduced single cavitation bubbles is investigated experimentally. An

  13. A prediction for bubbling geometries

    OpenAIRE

    Okuda, Takuya

    2007-01-01

    We study the supersymmetric circular Wilson loops in N=4 Yang-Mills theory. Their vacuum expectation values are computed in the parameter region that admits smooth bubbling geometry duals. The results are a prediction for the supergravity action evaluated on the bubbling geometries for Wilson loops.

  14. Vapor Bubbles in Flow and Acoustic Fields

    NARCIS (Netherlands)

    Prosperetti, Andrea; Hao, Yue; Sadhal, S.S

    2002-01-01

    A review of several aspects of the interaction of bubbles with acoustic and flow fields is presented. The focus of the paper is on bubbles in hot liquids, in which the bubble contains mostly vapor, with little or no permanent gas. The topics covered include the effect of translation on condensation

  15. Chronic Venous Disease under pressure

    NARCIS (Netherlands)

    S.W.I. Reeder (Suzan)

    2013-01-01

    textabstractIn chapter 1 we provide a general introduction of this thesis. Chronic venous disease (CVD) is a common medical condition that affects 2-64% of the worldwide population and leads to leg ulcers in 1% of the Western population. Venous leg ulceration (VLU) has an unfavorable prognosis with

  16. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    Science.gov (United States)

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  17. Cerebral venous and sinus thrombosis with cerebrospinal fluid circulation block after the first methotrexate administration by lumbar puncture

    International Nuclear Information System (INIS)

    Bienfait, H.P.; Gijtenbeek, J.M.M.; Bent, M.J. van; Bruin, H.G. de; Voogt, P.J.; Pillay, M.

    2002-01-01

    We report a patient treated for small lymphocytic lymphoma/leukemia with cerebral venous and sinus thrombosis (CVST) after lumbar puncture with intrathecal administration of methotrexate (MTX). He also developed a cerebrospinal fluid flow block. This is the first report of an association between lumbar puncture and intrathecally administered MTX and the development of CVST. Intrathecal treatment in this patient was discontinued and he was successfully treated with high-dose low-molecular-weight heparin subcutaneously. (orig.)

  18. Holography in small bubble chambers

    International Nuclear Information System (INIS)

    Lecoq, P.

    1984-01-01

    This chapter reports on an experiment to determine the total charm cross section at different incident momenta using the small, heavy liquid bubble chamber HOBC. Holography in liquid hydrogen is also tested using the holographic lexan bubble chamber HOLEBC with the aim of preparing a future holographic experiment in hydrogen. The high intensity tests show that more than 100 incident tracks per hologram do not cause a dramatic effect on the picture quality. Hydrogen is more favorable than freon as the bubble growth is much slower in hydrogen. An advantage of holography is to have the maximum resolution in the full volume of the bubble chamber, which allows a gain in sensitivity by a factor of 10 compared to classical optics as 100 tracks per hologram look reasonable. Holograms are not more difficult to analyze than classical optics high-resolution pictures. The results show that holography is a very powerful technique which can be used in very high resolution particle physics experiments

  19. Raman Spectral Band Oscillations in Large Graphene Bubbles

    Science.gov (United States)

    Huang, Yuan; Wang, Xiao; Zhang, Xu; Chen, Xianjue; Li, Baowen; Wang, Bin; Huang, Ming; Zhu, Chongyang; Zhang, Xuewei; Bacsa, Wolfgang S.; Ding, Feng; Ruoff, Rodney S.

    2018-05-01

    Raman spectra of large graphene bubbles showed size-dependent oscillations in spectral intensity and frequency, which originate from optical standing waves formed in the vicinity of the graphene surface. At a high laser power, local heating can lead to oscillations in the Raman frequency and also create a temperature gradient in the bubble. Based on Raman data, the temperature distribution within the graphene bubble was calculated, and it is shown that the heating effect of the laser is reduced when moving from the center of a bubble to its edge. By studying graphene bubbles, both the thermal conductivity and chemical reactivity of graphene were assessed. When exposed to hydrogen plasma, areas with bubbles are found to be more reactive than flat graphene.

  20. Thermal hydraulic phenomenology for the heating process in a natural circulation facility

    International Nuclear Information System (INIS)

    Torres, Walmir M.; Macedo, Luiz A.; Mesquita, Roberto N.; Masotti, Paulo Henrique F.; Libardi, Rosani Maria P.; Sabundjian, Gaiane; Andrade, Delvonei A.; Umbehaun, Pedro Ernesto; Conti, Thadeu N.; Silva Filho, Mauro F.S.; Melo, Gabriel R.

    2009-01-01

    This work describes thermal hydraulic phenomenology observed for the heating process in a natural circulation facility. Glass made circuit allows observations of the thermal hydraulic processes over several regions. Natural convection, natural circulation, nucleated sub-cooled, saturated boiling and some flow patterns such as, bubbly, slug and churn flow are observed and described. Facility heated and cooled parts are responsible for the natural circulation when in operation. An expansion tank accommodates the fluid density variations due to the temperature changes and void fraction. Instrumentation consists of thermocouples distributed along the circuit. Two differential pressure transducers are used for pressure and level measurements. Instrumentation signals and images are simultaneously acquired to help with phenomenon description. A CCD digital camera at a 250μs shutter speed is used for the images acquisition. Phenomenology described is based on a test under 1.1 x 10 5 W/m 2 of heat flux which corresponds to an electrical heater power of 7000 W and 0.0236 kg/s (85 l/h) of cooling flow rate. (author)

  1. Surgical management of venous malformations.

    Science.gov (United States)

    Loose, D A

    2007-01-01

    Among vascular malformations, the predominantly venous malformations represent the majority of cases. They form a clinical entity and therefore need clear concepts concerning diagnosis and treatment. This paper presents an overview of contemporary classification as well as tactics and techniques of treatment. According to the Hamburg Classification, predominantly venous malformations are categorized into truncular and extratruncular forms, with truncular forms distinguished as obstructions and dilations, and extratruncular forms as limited or infiltrating. The tactics of treatment represent surgical and non-surgical methods or combined techniques. Surgical approaches utilize different tactics and techniques that are adopted based on the pathologic form and type of the malformation: (I) operation to reduce the haemodynamic activity of the malformation; (II) operation to eliminate the malformation; and (III) reconstructive operation. As for (I), a type of a tactic is the operation to derive the venous flow. In (II), the total or partial removal of the venous malformation is demonstrated subdivided into three different techniques. In this way, the infiltrating as well as the limited forms can be treated. An additional technique is dedicated to the treatment of a marginal vein. Approach (III) involves the treatment of venous aneurysms, where a variety of techniques have been successful. Long-term follow-up demonstrates positive results in 91% of the cases. Congenital predominantly venous malformations should be treated according to the principles developed during the past decades in vascular surgery, interventional treatment and multidisciplinary treatment. The days of predominantly conservative treatment should be relegated to the past. Special skills and experiences are necessary to carry out appropriate surgical strategy, and the required operative techniques should be dictated by the location and type of malformation and associated findings.

  2. Two types of nonlinear wave equations for diffractive beams in bubbly liquids with nonuniform bubble number density.

    Science.gov (United States)

    Kanagawa, Tetsuya

    2015-05-01

    This paper theoretically treats the weakly nonlinear propagation of diffracted sound beams in nonuniform bubbly liquids. The spatial distribution of the number density of the bubbles, initially in a quiescent state, is assumed to be a slowly varying function of the spatial coordinates; the amplitude of variation is assumed to be small compared to the mean number density. A previous derivation method of nonlinear wave equations for plane progressive waves in uniform bubbly liquids [Kanagawa, Yano, Watanabe, and Fujikawa (2010). J. Fluid Sci. Technol. 5(3), 351-369] is extended to handle quasi-plane beams in weakly nonuniform bubbly liquids. The diffraction effect is incorporated by adding a relation that scales the circular sound source diameter to the wavelength into the original set of scaling relations composed of nondimensional physical parameters. A set of basic equations for bubbly flows is composed of the averaged equations of mass and momentum, the Keller equation for bubble wall, and supplementary equations. As a result, two types of evolution equations, a nonlinear Schrödinger equation including dissipation, diffraction, and nonuniform effects for high-frequency short-wavelength case, and a Khokhlov-Zabolotskaya-Kuznetsov equation including dispersion and nonuniform effects for low-frequency long-wavelength case, are derived from the basic set.

  3. Approaching behavior of a pair of spherical bubbles in quiescent liquids

    Science.gov (United States)

    Sanada, Toshiyuki; Kusuno, Hiroaki

    2015-11-01

    Some unique motions related bubble-bubble interaction, such as equilibrium distance, wake induced lift force, have been proposed by theoretical analysis or numerical simulations. These motions are different from the solid spheres like DKT model (Drafting, Kissing and Tumbling). However, there is a lack of the experimental verification. In this study, we experimentally investigated the motion of a pair of bubbles initially positioned in-line configuration in ultrapure water or an aqueous surfactant solution. The bubble motion were observed by two high speed video cameras. The bubbles Reynolds number was ranged from 50 to 300 and bubbles hold the spherical shape in this range. In ultrapure water, initially the trailing bubble deviated from the vertical line on the leading bubble owing to the wake of the leading bubble. And then, the slight difference of the bubble radius changed the relative motion. When the trailing bubble slightly larger than the leading bubble, the trailing bubble approached to the leading bubble due to it's buoyancy difference. The bubbles attracted and collided only when the bubbles rising approximately side by side configuration. In addition, we will also discuss the motion of bubbles rising in an aqueous surfactant solution.

  4. Bubble nuclei in relativistic mean field theory

    International Nuclear Information System (INIS)

    Shukla, A.; Aberg, S.; Patra, S.K.

    2011-01-01

    Bubble nuclei are characterized by a depletion of their central density, i.e. the formation of the proton or neutron void and subsequently forming proton or neutron bubble nuclei. Possibility of the formation of bubble nuclei has been explored through different nuclear models and in different mass regions. Advancements in experimental nuclear physics has led our experimental access to many new shapes and structures, which were inaccessible hitherto. In the present paper, the possibility of observing nuclear bubble in oxygen isotopes, particularly for 22 O has been studied

  5. Methane emission by bubbling from Gatun Lake, Panama

    Science.gov (United States)

    Keller, Michael; Stallard, Robert F.

    1994-01-01

    We studied methane emission by bubbling from Gatun Lake, Panama, at water depths of less than 1 m to about 10 m. Gas bubbles were collected in floating traps deployed during 12- to 60-hour observation periods. Comparison of floating traps and floating chambers showed that about 98% of methane emission occurred by bubbling and only 2% occurred by diffusion. Average methane concentration of bubbles at our sites varied from 67% to 77%. Methane emission by bubbling occurred episodically, with greatest rates primarily between the hours of 0800 and 1400 LT. Events appear to be triggered by wind. The flux of methane associated with bubbling was strongly anticorrelated with water depth. Seasonal changes in water depth caused seasonal variation of methane emission. Bubble methane fluxes through the lake surface into the atmosphere measured during 24-hour intervals were least (10-200 mg/m2/d) at deeper sites (greater than 7 m) and greatest (300-2000 mg/m2/d) at shallow sites (less than 2 m).

  6. Numerical modeling of bubble dynamics in magmas

    Science.gov (United States)

    Huber, Christian; Su, Yanqing; Parmigiani, Andrea

    2014-05-01

    Understanding the complex non-linear physics that governs volcanic eruptions is contingent on our ability to characterize the dynamics of bubbles and its effect on the ascending magma. The exsolution and migration of bubbles has also a great impact on the heat and mass transport in and out of magma bodies stored at shallow depths in the crust. Multiphase systems like magmas are by definition heterogeneous at small scales. Although mixture theory or homogenization methods are convenient to represent multiphase systems as a homogeneous equivalent media, these approaches do not inform us on possible feedbacks at the pore-scale and can be significantly misleading. In this presentation, we discuss the development and application of bubble-scale multiphase flow modeling to address the following questions : How do bubbles impact heat and mass transport in magma chambers ? How efficient are chemical exchanges between the melt and bubbles during magma decompression? What is the role of hydrodynamic interactions on the deformation of bubbles while the magma is sheared? Addressing these questions requires powerful numerical methods that accurately model the balance between viscous, capillary and pressure stresses. We discuss how these bubble-scale models can provide important constraints on the dynamics of magmas stored at shallow depth or ascending to the surface during an eruption.

  7. Bubbly flows around a two-dimensional circular cylinder

    Science.gov (United States)

    Lee, Jubeom; Park, Hyungmin

    2016-11-01

    Two-phase cross flows around a bluff body occur in many thermal-fluid systems like steam generators, heat exchangers and nuclear reactors. However, our current knowledge on the interactions among bubbles, bubble-induced flows and the bluff body are limited. In the present study, the gas-liquid bubbly flows around a solid circular cylinder are experimentally investigated while varying the mean void fraction from 5 to 27%. The surrounding liquid (water) is initially static and the liquid flow is only induced by the air bubbles. For the measurements, we use the high-speed two-phase particle image velocimetry techniques. First, depending on the mean void fraction, two regimes are classified with different preferential concentration of bubbles in the cylinder wake, which are explained in terms of hydrodynamic force balances acting on rising bubbles. Second, the differences between the two-phase and single-phase flows (while matching their Reynolds numbers) around a circular cylinder will be discussed in relation to effects of bubble dynamics and the bubble-induced turbulence on the cylinder wake. Supported by a Grant (MPSS-CG-2016-02) through the Disaster and Safety Management Institute funded by Ministry of Public Safety and Security of Korean government.

  8. Modeling of the evolution of bubble size distribution of gas-liquid flow inside a large vertical pipe. Influence of bubble coalescence and breakup models

    International Nuclear Information System (INIS)

    Liao, Yixiang; Lucas, Dirk

    2011-01-01

    The range of gas-liquid flow applications in today's technology is immensely wide. Important examples can be found in chemical reactors, boiling and condensation equipments as well as nuclear reactors. In gas-liquid flows, the bubble size distribution plays an important role in the phase structure and interfacial exchange behaviors. It is therefore necessary to take into account the dynamic change of the bubble size distribution to get good predictions in CFD. An efficient 1D Multi-Bubble-Size-Class Test Solver was introduced in Lucas et al. (2001) for the simulation of the development of the flow structure along a vertical pipe. The model considers a large number of bubble classes. It solves the radial profiles of liquid and gas velocities, bubble-size class resolved gas fraction profiles as well as turbulence parameters on basis of the bubble size distribution present at the given axial position. The evolution of the flow along the height is assumed to be solely caused by the progress of bubble coalescence and break-up resulting in a bubble size distribution changing in the axial direction. In this model, the bubble coalescence and breakup models are very important for reasonable predictions of the bubble size distribution. Many bubble coalescence and breakup models have been proposed in the literature. However, some obvious discrepancies exist in the models; for example, the daughter bubble size distributions are greatly different from different bubble breakup models, as reviewed in our previous publication (Liao and Lucas, 2009a; 2010). Therefore, it is necessary to compare and evaluate typical bubble coalescence and breakup models that have been commonly used in the literature. Thus, this work is aimed to make a comparison of several typical bubble coalescence and breakup models and to discuss in detail the ability of the Test Solver to predict the evolution of bubble size distribution. (orig.)

  9. Poor Prognosis Indicated by Venous Circulating Tumor Cell Clusters in Early-Stage Lung Cancers.

    Science.gov (United States)

    Murlidhar, Vasudha; Reddy, Rishindra M; Fouladdel, Shamileh; Zhao, Lili; Ishikawa, Martin K; Grabauskiene, Svetlana; Zhang, Zhuo; Lin, Jules; Chang, Andrew C; Carrott, Philip; Lynch, William R; Orringer, Mark B; Kumar-Sinha, Chandan; Palanisamy, Nallasivam; Beer, David G; Wicha, Max S; Ramnath, Nithya; Azizi, Ebrahim; Nagrath, Sunitha

    2017-09-15

    Early detection of metastasis can be aided by circulating tumor cells (CTC), which also show potential to predict early relapse. Because of the limited CTC numbers in peripheral blood in early stages, we investigated CTCs in pulmonary vein blood accessed during surgical resection of tumors. Pulmonary vein (PV) and peripheral vein (Pe) blood specimens from patients with lung cancer were drawn during the perioperative period and assessed for CTC burden using a microfluidic device. From 108 blood samples analyzed from 36 patients, PV had significantly higher number of CTCs compared with preoperative Pe ( P ontology analysis revealed enrichment of cell migration and immune-related pathways in CTC clusters, suggesting survival advantage of clusters in circulation. Clusters display characteristics of therapeutic resistance, indicating the aggressive nature of these cells. Thus, CTCs isolated from early stages of lung cancer are predictive of poor prognosis and can be interrogated to determine biomarkers predictive of recurrence. Cancer Res; 77(18); 5194-206. ©2017 AACR . ©2017 American Association for Cancer Research.

  10. Herds of methane chambers grazing bubbles

    Science.gov (United States)

    Grinham, Alistair; Dunbabin, Matthew

    2014-05-01

    Water to air methane emissions from freshwater reservoirs can be dominated by sediment bubbling (ebullitive) events. Previous work to quantify methane bubbling from a number of Australian sub-tropical reservoirs has shown that this can contribute as much as 95% of total emissions. These bubbling events are controlled by a variety of different factors including water depth, surface and internal waves, wind seiching, atmospheric pressure changes and water levels changes. Key to quantifying the magnitude of this emission pathway is estimating both the bubbling rate as well as the areal extent of bubbling. Both bubbling rate and areal extent are seldom constant and require persistent monitoring over extended time periods before true estimates can be generated. In this paper we present a novel system for persistent monitoring of both bubbling rate and areal extent using multiple robotic surface chambers and adaptive sampling (grazing) algorithms to automate the quantification process. Individual chambers are self-propelled and guided and communicate between each other without the need for supervised control. They can maintain station at a sampling site for a desired incubation period and continuously monitor, record and report fluxes during the incubation. To exploit the methane sensor detection capabilities, the chamber can be automatically lowered to decrease the head-space and increase concentration. The grazing algorithms assign a hierarchical order to chambers within a preselected zone. Chambers then converge on the individual recording the highest 15 minute bubbling rate. Individuals maintain a specified distance apart from each other during each sampling period before all individuals are then required to move to different locations based on a sampling algorithm (systematic or adaptive) exploiting prior measurements. This system has been field tested on a large-scale subtropical reservoir, Little Nerang Dam, and over monthly timescales. Using this technique

  11. How Stressful Is "Deep Bubbling"?

    Science.gov (United States)

    Tyrmi, Jaana; Laukkanen, Anne-Maria

    2017-03-01

    Water resistance therapy by phonating through a tube into the water is used to treat dysphonia. Deep submersion (≥10 cm in water, "deep bubbling") is used for hypofunctional voice disorders. Using it with caution is recommended to avoid vocal overloading. This experimental study aimed to investigate how strenuous "deep bubbling" is. Fourteen subjects, half of them with voice training, repeated the syllable [pa:] in comfortable speaking pitch and loudness, loudly, and in strained voice. Thereafter, they phonated a vowel-like sound both in comfortable loudness and loudly into a glass resonance tube immersed 10 cm into the water. Oral pressure, contact quotient (CQ, calculated from electroglottographic signal), and sound pressure level were studied. The peak oral pressure P(oral) during [p] and shuttering of the outer end of the tube was measured to estimate the subglottic pressure P(sub) and the mean P(oral) during vowel portions to enable calculation of transglottic pressure P(trans). Sensations during phonation were reported with an open-ended interview. P(sub) and P(oral) were higher in "deep bubbling" and P(trans) lower than in loud syllable phonation, but the CQ did not differ significantly. Similar results were obtained for the comparison between loud "deep bubbling" and strained phonation, although P(sub) did not differ significantly. Most of the subjects reported "deep bubbling" to be stressful only for respiratory and lip muscles. No big differences were found between trained and untrained subjects. The CQ values suggest that "deep bubbling" may increase vocal fold loading. Further studies should address impact stress during water resistance exercises. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  12. Two-fluid model LES of a bubble column

    International Nuclear Information System (INIS)

    Brahma N Reddy Vanga; Martin A Lopez de Bertodano; Eckhard Krepper; Alexandr Zaruba; Horst-Michael Prasser

    2005-01-01

    The hydrodynamics of a rectangular bubble column operating in the dispersed bubbly regime has been numerically investigated using a two-fluid model Large Eddy Simulation (LES). Experimental data were obtained to validate the model. LES computational fluid dynamic calculations of the transient flow for the bubble column were performed to account for the turbulence in the liquid phase. The computational mesh is of the same scale as the bubble size. The sub grid-scale Reynolds stresses were calculated with the Smagorinsky model. Furthermore, the effect of the bubbles on the turbulence in the continuous phase was modeled using Sato's eddy viscosity model for bubble-induced turbulence. Mean quantities were computed by averaging over a time period that was longer than the dynamic time scales of the turbulence, in particular the void fraction and the average velocity of the bubbles. A systematic analysis of the effect of the interfacial momentum transfer terms on these quantities has been conducted. The bubble column was locally aerated using a sparger located in the center of the bottom plate. The experimental studies involve wire-mesh tomography measurements for void fraction and bubble size distributions and digital image processing of high speed camera images for estimation of bubble velocities, size distributions and flow patterns. Experiments were performed for various aspect ratios (height of water column to width ratio) and superficial gas velocities. It was found that the non-drag bubble forces play a very prominent role in the predicting the correct flow pattern and void fraction distributions. In the calculations, the lift force and the wall force were considered. A 'wall peak' in the time averaged void fraction distribution has been experimentally observed and this cannot be predicted without including these non-drag forces in the numerical calculations. In this paper, experimental data are compared with the results of the numerical simulations. (authors)

  13. Numerical investigation of interaction between rising bubbles in a viscous liquid

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ik Roh [Korea Institute of Marine Science and Technology Promotion, Seoul (Korea, Republic of); Shin Seung Won [Hongik University, Seoul (Korea, Republic of)

    2016-07-15

    The rising behavior of bubbles undergoing bubble-bubble interaction in a viscous liquid is studied using a two-dimensional direct numerical simulation. Level contour reconstruction method (LCRM), one of the connectivity-free front tracking methods, is applied to describe a moving interface accurately under highly deformable conditions. This work focuses on the effects of bubble size on the interaction of two bubbles rising side-by-side in a stagnant liquid. Several characteristics of bubble-bubble interaction are analyzed quantitatively as supported by energy analysis. The results showed clear differences between small and large bubbles with respect to their interaction behavior in terms of lateral movement, vortex intensity, suppression of surface deformation, and viscous dissipation rate. Distributions of vorticity and viscous dissipation rate near the bubble interfaces also differed depending on the size of the bubbles. Strong vortices from large bubbles triggered oscillation in bubble-bubble interaction and played a dominant role in the interaction process as the size of bubbles increases.

  14. Prevalence of lower extremity venous duplication

    Directory of Open Access Journals (Sweden)

    Simpson William

    2010-01-01

    Full Text Available Purpose: This retrospective study was performed to determine the prevalence of lower extremity venous duplication using duplex ultrasound in the patient population of a large urban medical center. Materials and Methods: The reports of all lower extremity venous ultrasound examinations performed at our institution between January 1, 2002 and December 31, 2002 were reviewed. Ultrasound examinations that were performed for purposes other than the detection of lower extremity deep vein thrombosis were excluded. The prevalence of duplication and its specific location were recorded. In addition, the prevalence of thrombus and its specific location were also recorded. Results: A total of 3118 exams were performed in 2664 patients. Of the 2664 patients, 2311 had only one examination performed during the study period; 353 patients had more than one examination performed. We found that 10.1% of patients (270/2664 had at least one venous segment duplicated and 5.4% of patients (143/2664 had a thrombus in at least one venous segment. There was a statistically significant difference in the prevalence of both duplication and thrombus with a change in venous segment. Only 0.4% of patients (11/2664 had thrombus within a duplicated segment. Of those who had more than one examination performed, 15.3% (54/353 had the same venous segment(s seen on one examination but not another. Conclusion: Lower extremity venous duplication is a frequent anatomic variant that is seen in 10.1% of patients, but it may not be as common as is generally believed. It can result in a false negative result for deep vein thrombosis.

  15. Pressure waves in a supersaturated bubbly magma

    Science.gov (United States)

    Kurzon, I.; Lyakhovsky, V.; Navon, O.; Chouet, B.

    2011-01-01

    We study the interaction of acoustic pressure waves with an expanding bubbly magma. The expansion of magma is the result of bubble growth during or following magma decompression and leads to two competing processes that affect pressure waves. On the one hand, growth in vesicularity leads to increased damping and decreased wave amplitudes, and on the other hand, a decrease in the effective bulk modulus of the bubbly mixture reduces wave velocity, which in turn, reduces damping and may lead to wave amplification. The additional acoustic energy originates from the chemical energy released during bubble growth. We examine this phenomenon analytically to identify conditions under which amplification of pressure waves is possible. These conditions are further examined numerically to shed light on the frequency and phase dependencies in relation to the interaction of waves and growing bubbles. Amplification is possible at low frequencies and when the growth rate of bubbles reaches an optimum value for which the wave velocity decreases sufficiently to overcome the increased damping of the vesicular material. We examine two amplification phase-dependent effects: (1) a tensile-phase effect in which the inserted wave adds to the process of bubble growth, utilizing the energy associated with the gas overpressure in the bubble and therefore converting a large proportion of this energy into additional acoustic energy, and (2) a compressive-phase effect in which the pressure wave works against the growing bubbles and a large amount of its acoustic energy is dissipated during the first cycle, but later enough energy is gained to amplify the second cycle. These two effects provide additional new possible mechanisms for the amplification phase seen in Long-Period (LP) and Very-Long-Period (VLP) seismic signals originating in magma-filled cracks.

  16. Bubble coalescence in a Newtonian fluid

    Science.gov (United States)

    Garg, Vishrut; Basaran, Osman

    2017-11-01

    Bubble coalescence plays a central role in the hydrodynamics of gas-liquid systems such as bubble column reactors, spargers, and foams. Two bubbles approaching each other at velocity V coalesce when the thin film between them ruptures, which is often the rate-limiting step. Experimental studies of this system are difficult, and recent works provide conflicting results on the effect of V on coalescence times. We simulate the head-on approach of two bubbles of equal radii R in an incompressible Newtonian fluid (density ρ, viscosity μ, and surface tension σ) by solving numerically the free boundary problem comprised of the Navier Stokes and continuity equations. Simulations are made challenging by the existence of highly disparate lengthscales, i.e. film thickness and drop radii, which are resolved by using the method of elliptic mesh generation. For a given liquid, the bubbles are shown to coalesce for all velocities below a critical value. The effects of Ohnesorge number Oh = μ /√{ ρσR } on coalescence time and critical velocity are also investigated.

  17. Photothermally controlled Marangoni flow around a micro bubble

    International Nuclear Information System (INIS)

    Namura, Kyoko; Nakajima, Kaoru; Kimura, Kenji; Suzuki, Motofumi

    2015-01-01

    We have experimentally investigated the control of Marangoni flow around a micro bubble using photothermal conversion. Using a focused laser spot acting as a highly localized heat source on Au nanoparticles/dielectric/Ag mirror thin film enables us to create a micro bubble and to control the temperature gradient around the bubble at a micrometer scale. When we irradiate the laser next to the bubble, a strong main flow towards the bubble and two symmetric rotation flows on either side of it develop. The shape of this rotation flow shows a significant transformation depending on the relative position of the bubble and the laser spot. Using this controllable rotation flow, we have demonstrated sorting of the polystyrene spheres with diameters of 2 μm and 0.75 μm according to their size

  18. Photothermally controlled Marangoni flow around a micro bubble

    Science.gov (United States)

    Namura, Kyoko; Nakajima, Kaoru; Kimura, Kenji; Suzuki, Motofumi

    2015-01-01

    We have experimentally investigated the control of Marangoni flow around a micro bubble using photothermal conversion. Using a focused laser spot acting as a highly localized heat source on Au nanoparticles/dielectric/Ag mirror thin film enables us to create a micro bubble and to control the temperature gradient around the bubble at a micrometer scale. When we irradiate the laser next to the bubble, a strong main flow towards the bubble and two symmetric rotation flows on either side of it develop. The shape of this rotation flow shows a significant transformation depending on the relative position of the bubble and the laser spot. Using this controllable rotation flow, we have demonstrated sorting of the polystyrene spheres with diameters of 2 μm and 0.75 μm according to their size.

  19. Bubble coalescence in breathing DNA

    DEFF Research Database (Denmark)

    Novotný, Tomas; Pedersen, Jonas Nyvold; Ambjörnsson, Tobias

    2007-01-01

    We investigate the coalescence of two DNA bubbles initially located at weak segments and separated by a more stable barrier region in a designed construct of double-stranded DNA. The characteristic time for bubble coalescence and the corresponding distribution are derived, as well as the distribu...... vicious walkers in opposite potentials....

  20. Intestinal circulation during inhalation anesthesia

    International Nuclear Information System (INIS)

    Tverskoy, M.; Gelman, S.; Fowler, K.C.; Bradley, E.L.

    1985-01-01

    This study was designed to evaluate the influence of inhalational agents on the intestinal circulation in an isolated loop preparation. Sixty dogs were studied, using three intestinal segments from each dog. Selected intestinal segments were pumped with aortic blood at a constant pressure of 100 mmHg. A mixture of 86 Rb and 9-microns spheres labeled with 141 Ce was injected into the arterial cannula supplying the intestinal loop, while mesenteric venous blood was collected for activity counting. A very strong and significant correlation was found between rubidium clearance and microsphere entrapment (r = 0.97, P less than 0.0001). Nitrous oxide anesthesia was accompanied by a higher vascular resistance (VR), lower flow (F), rubidium clearance (Cl-Rb), and microspheres entrapment (Cl-Sph) than pentobarbital anesthesia, indicating that the vascular bed in the intestinal segment was constricted and flow (total and nutritive) decreased. Halothane, enflurane, and isoflurane anesthesia were accompanied by a much lower arteriovenous oxygen content difference (AVDO 2 ) and oxygen uptake than pentobarbital or nitrous oxide. Compared with pentobarbital, enflurane anesthesia was not accompanied by marked differences in VR, F, Cl-Rb, and Cl-Sph; halothane at 2 MAC decreased VR and increased F and Cl-Rb while isoflurane increased VR and decreased F. alpha-Adrenoceptor blockade with phentolamine (1 mg . kg-1) abolished isoflurane-induced vasoconstriction, suggesting that the increase in VR was mediated via circulating catecholamines

  1. Generation of a bubble universe using a negative energy bath

    International Nuclear Information System (INIS)

    Hwang, Dong-il; Yeom, Dong-han

    2011-01-01

    This paper suggests a model for a bubble universe using buildable false vacuum bubbles. We study the causal structures of collapsing false vacuum bubbles using double-null simulations. False vacuum bubbles violate the null energy condition and emit negative energy along the outgoing direction through semi-classical effects. If there are a few collapsing false vacuum bubbles and they emit negative energy to a certain region, then the region can be approximated by a negative energy bath, which means that the region is homogeneously filled by negative energy. If a false vacuum bubble is generated in the negative energy bath and the tension of the bubble effectively becomes negative in the bath, then the bubble can expand and form an inflating bubble universe. This scenario uses a set of assumptions different from those in previous studies because it does not require tunneling to unbuildable bubbles.

  2. Eternal inflation, bubble collisions, and the persistence of memory

    International Nuclear Information System (INIS)

    Garriga, Jaume; Guth, Alan H.; Vilenkin, Alexander

    2007-01-01

    A 'bubble universe' nucleating in an eternally inflating false vacuum will experience, in the course of its expansion, collisions with an infinite number of other bubbles. In an idealized model, we calculate the rate of collisions around an observer inside a given reference bubble. We show that the collision rate violates both the homogeneity and the isotropy of the bubble universe. Each bubble has a center which can be related to 'the beginning of inflation' in the parent false vacuum, and any observer not at the center will see an anisotropic bubble collision rate that peaks in the outward direction. Surprisingly, this memory of the onset of inflation persists no matter how much time elapses before the nucleation of the reference bubble

  3. Bubble nonlinear dynamics and stimulated scattering process

    Science.gov (United States)

    Jie, Shi; De-Sen, Yang; Sheng-Guo, Shi; Bo, Hu; Hao-Yang, Zhang; Shi-Yong, Hu

    2016-02-01

    A complete understanding of the bubble dynamics is deemed necessary in order to achieve their full potential applications in industry and medicine. For this purpose it is first needed to expand our knowledge of a single bubble behavior under different possible conditions including the frequency and pressure variations of the sound field. In addition, stimulated scattering of sound on a bubble is a special effect in sound field, and its characteristics are associated with bubble oscillation mode. A bubble in liquid can be considered as a representative example of nonlinear dynamical system theory with its resonance, and its dynamics characteristics can be described by the Keller-Miksis equation. The nonlinear dynamics of an acoustically excited gas bubble in water is investigated by using theoretical and numerical analysis methods. Our results show its strongly nonlinear behavior with respect to the pressure amplitude and excitation frequency as the control parameters, and give an intuitive insight into stimulated sound scattering on a bubble. It is seen that the stimulated sound scattering is different from common dynamical behaviors, such as bifurcation and chaos, which is the result of the nonlinear resonance of a bubble under the excitation of a high amplitude acoustic sound wave essentially. The numerical analysis results show that the threshold of stimulated sound scattering is smaller than those of bifurcation and chaos in the common condition. Project supported by the Program for Changjiang Scholars and Innovative Research Team in University, China (Grant No. IRT1228) and the Young Scientists Fund of the National Natural Science Foundation of China (Grant Nos. 11204050 and 11204049).

  4. Bubble chamber: antiproton annihilation

    CERN Multimedia

    1971-01-01

    These images show real particle tracks from the annihilation of an antiproton in the 80 cm Saclay liquid hydrogen bubble chamber. A negative kaon and a neutral kaon are produced in this process, as well as a positive pion. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that had been heated to boiling point.

  5. Bubble shape in horizontal and near horizontal intermittent flow

    International Nuclear Information System (INIS)

    Gu, Hanyang; Guo, Liejin

    2015-01-01

    Highlights: • The bubble shapes in intermittent flows are presented experimentally. • The nose-tail inversion phenomenon appears at a low Froude number in downward pipe. • Transition from plug to slug flow occurs when the bubble tail changes from staircase pattern to hydraulic jump. - Abstract: This paper presents an experimental study of the shape of isolated bubbles in horizontal and near horizontal intermittent flows. It is found that the shapes of the nose and body of bubble depend on the Froude number defined by gas/liquid mixture velocity in a pipe, whereas the shape of the back of bubble region depends on both the Froude number and bubble length. The photographic studies show that the transition from plug to slug flow occurs when the back of the bubble changes from staircase pattern to hydraulic jump with the increase of the Froude number and bubble length. The effect of pipe inclination on characteristics of bubble is significant: The bubble is inversely located in a downwardly inclined pipe when the Froude number is low, and the transition from plug flow to slug flow in an upward inclined pipe is more ready to occur compared with that in a downwardly inclined pipe

  6. The influence of bubbles on the perception carbonation bite.

    Directory of Open Access Journals (Sweden)

    Paul M Wise

    Full Text Available Although many people naively assume that the bite of carbonation is due to tactile stimulation of the oral cavity by bubbles, it has become increasingly clear that carbonation bite comes mainly from formation of carbonic acid in the oral mucosa. In Experiment 1, we asked whether bubbles were in fact required to perceive carbonation bite. Subjects rated oral pungency from several concentrations of carbonated water both at normal atmospheric pressure (at which bubbles could form and at 2.0 atmospheres pressure (at which bubbles did not form. Ratings of carbonation bite under the two pressure conditions were essentially identical, indicating that bubbles are not required for pungency. In Experiment 2, we created controlled streams of air bubbles around the tongue in mildly pungent CO2 solutions to determine how tactile stimulation from bubbles affects carbonation bite. Since innocuous sensations like light touch and cooling often suppress pain, we predicted that bubbles might reduce rated bite. Contrary to prediction, air bubbles flowing around the tongue significantly enhanced rated bite, without inducing perceived bite in blank (un-carbonated solutions. Accordingly, though bubbles are clearly not required for carbonation bite, they may well modulate perceived bite. More generally, the results show that innocuous tactile stimulation can enhance chemogenic pain. Possible physiological mechanisms are discussed.

  7. Hydrodynamic interaction on large-Reynolds-number aligned bubbles: Drag effects

    International Nuclear Information System (INIS)

    Ramirez-Munoz, J.; Salinas-Rodriguez, E.; Soria, A.; Gama-Goicochea, A.

    2011-01-01

    Graphical abstract: Display Omitted Highlights: → The hydrodynamic interaction of a pair aligned equal-sized bubbles is analyzed. → The leading bubble wake decreases the drag on the trailing bubble. → A new semi-analytical model for the trailing bubble's drag is presented. → The equilibrium distance between bubbles is predicted. - Abstract: The hydrodynamic interaction of two equal-sized spherical gas bubbles rising along a vertical line with a Reynolds number (Re) between 50 and 200 is analyzed. An approach to estimate the trailing bubble drag based on the search of a proper reference fluid velocity is proposed. Our main result is a new, simple semi-analytical model for the trailing bubble drag. Additionally, the equilibrium separation distance between bubbles is predicted. The proposed models agree quantitatively up to small distances between bubbles, with reported data for 50 ≤ Re ≤ 200. The relative average error for the trailing bubble drag, Er, is found to be in the range 1.1 ≤ Er ≤ 1.7, i.e., it is of the same order of the analytical predictions in the literature.

  8. Hydrodynamic interaction on large-Reynolds-number aligned bubbles: Drag effects

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez-Munoz, J., E-mail: jrm@correo.azc.uam.mx [Departamento de Energia, Universidad Autonoma Metropolitana-Azcapotzalco, Av. San Pablo 180, Col. Reynosa Tamaulipas, 02200 Mexico D.F. (Mexico); Centro de Investigacion en Polimeros, Marcos Achar Lobaton No. 2, Tepexpan, 55885 Acolman, Edo. de Mexico (Mexico); Salinas-Rodriguez, E.; Soria, A. [Departamento de IPH, Universidad Autonoma Metropolitana-Iztapalapa, San Rafael Atlixco 186, Col. Vicentina, Iztapalapa, 09340 Mexico D.F. (Mexico); Gama-Goicochea, A. [Centro de Investigacion en Polimeros, Marcos Achar Lobaton No. 2, Tepexpan, 55885 Acolman, Edo. de Mexico (Mexico)

    2011-07-15

    Graphical abstract: Display Omitted Highlights: > The hydrodynamic interaction of a pair aligned equal-sized bubbles is analyzed. > The leading bubble wake decreases the drag on the trailing bubble. > A new semi-analytical model for the trailing bubble's drag is presented. > The equilibrium distance between bubbles is predicted. - Abstract: The hydrodynamic interaction of two equal-sized spherical gas bubbles rising along a vertical line with a Reynolds number (Re) between 50 and 200 is analyzed. An approach to estimate the trailing bubble drag based on the search of a proper reference fluid velocity is proposed. Our main result is a new, simple semi-analytical model for the trailing bubble drag. Additionally, the equilibrium separation distance between bubbles is predicted. The proposed models agree quantitatively up to small distances between bubbles, with reported data for 50 {<=} Re {<=} 200. The relative average error for the trailing bubble drag, Er, is found to be in the range 1.1 {<=} Er {<=} 1.7, i.e., it is of the same order of the analytical predictions in the literature.

  9. Effect of hepatic venous sphincter contraction on transmission of central venous pressure to lobar and portal pressure.

    Science.gov (United States)

    Lautt, W W; Legare, D J; Greenway, C V

    1987-11-01

    In dogs anesthetized with pentobarbital, central vena caval pressure (CVP), portal venous pressure (PVP), and intrahepatic lobar venous pressure (proximal to the hepatic venous sphincters) were measured. The objective was to determine some characteristics of the intrahepatic vascular resistance sites (proximal and distal to the hepatic venous sphincters) including testing predictions made using a recent mathematical model of distensible hepatic venous resistance. The stimulus used was a brief rise in CVP produced by transient occlusion of the thoracic vena cava in control state and when vascular resistance was elevated by infusions of norepinephrine or histamine, or by nerve stimulation. The percent transmission of the downstream pressure rise to upstream sites past areas of vascular resistance was elevated. Even small increments in CVP are partially transmitted upstream. The data are incompatible with the vascular waterfall phenomenon which predicts that venous pressure increments are not transmitted upstream until a critical pressure is overcome and then further increments would be 100% transmitted. The hepatic sphincters show the following characteristics. First, small rises in CVP are transmitted less than large elevations; as the CVP rises, the sphincters passively distend and allow a greater percent transmission upstream, thus a large rise in CVP is more fully transmitted than a small rise in CVP. Second, the amount of pressure transmission upstream is determined by the vascular resistance across which the pressure is transmitted. As nerves, norepinephrine, or histamine cause the hepatic sphincters to contract, the percent transmission becomes less and the distensibility of the sphincters is reduced. Similar characteristics are shown for the "presinusoidal" vascular resistance and the hepatic venous sphincter resistance.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Normal venous anatomy and physiology of the lower extremity.

    Science.gov (United States)

    Notowitz, L B

    1993-06-01

    Venous disease of the lower extremities is common but is often misunderstood. It seems that the focus is on the exciting world of arterial anatomy and pathology, while the topic of venous anatomy and pathology comes in second place. However, venous diseases such as chronic venous insufficiency, leg ulcers, and varicose veins affect much of the population and may lead to disability and death. Nurses are often required to answer complex questions from the patients and his or her family about the patient's disease. Patients depend on nurses to provide accurate information in terms they can understand. Therefore it is important to have an understanding of the normal venous system of the legs before one can understand the complexities of venous diseases and treatments. This presents an overview of normal venous anatomy and physiology.

  11. Effect of microstructure on helium bubble growth in irradiated nickel

    International Nuclear Information System (INIS)

    Sattler, M.L.

    1986-01-01

    Thin nickel films were irradiated with 80 keV helium ions at varying doses and varying temperatures in order to obtain a variety of final microstructures. The growth of bubbles was examined during in-situ irradiations at 950 0 C where migration and coalescence events were observed for bubbles as large as 60 nm. Further direct observations of bubble growth were made during annealing of the irradiated specimens. For sample with no visible bubbles before annealing, the heating to 0.51 T/sub M/ produced bubbles that increased in diameter with annealing time to the power n. For bubbles in the grain interior, n ∼ 1, and on the grain boundaries, n ∼ 0.6. Since no migration and coalescence or ripening theories predict this behavior, a theory described by transient diffusion to spherical sinks was developed to discuss the behavior. This theory predicts that n = 1 for bubbles growing in the grain interior and n = 0.5 for bubbles on the grain boundary. In other annealing of irradiated samples containing large bubble populations, the growth of large bubbles and shrinking of small bubbles was observed at a temperature equal to 0.54 T/sub M/. The theory of Ostwald ripening properly described this type of bubble growth. Mass spectrometer measurements of He content in the irradiated specimens showed a greater He retention in the Ni films that contained a significant bubble population than those with no visible bubbles

  12. Sono-chemiluminescence from a single cavitation bubble in water

    International Nuclear Information System (INIS)

    Brotchie, Adam; Shchukin, Dmitry; Moehwald, Helmuth; Schneider, Julia; Pflieger, Rachel

    2012-01-01

    In summary, this study has revealed the conditions required for a single bubble to be sono-chemically active. Evidence of radical-induced processes surrounding the bubble was only observed below the SL threshold, where the bubble was not spatially stable, and did not correlate with emission from excited molecular states inside the bubble. Moreover, this work substantiates recent progress that has been made in bridging the gap between single and multi-bubble cavitation. (authors)

  13. Bubble behavior characteristics based on virtual binocular stereo vision

    Science.gov (United States)

    Xue, Ting; Xu, Ling-shuang; Zhang, Shang-zhen

    2018-01-01

    The three-dimensional (3D) behavior characteristics of bubble rising in gas-liquid two-phase flow are of great importance to study bubbly flow mechanism and guide engineering practice. Based on the dual-perspective imaging of virtual binocular stereo vision, the 3D behavior characteristics of bubbles in gas-liquid two-phase flow are studied in detail, which effectively increases the projection information of bubbles to acquire more accurate behavior features. In this paper, the variations of bubble equivalent diameter, volume, velocity and trajectory in the rising process are estimated, and the factors affecting bubble behavior characteristics are analyzed. It is shown that the method is real-time and valid, the equivalent diameter of the rising bubble in the stagnant water is periodically changed, and the crests and troughs in the equivalent diameter curve appear alternately. The bubble behavior characteristics as well as the spiral amplitude are affected by the orifice diameter and the gas volume flow.

  14. Can airborne ultrasound monitor bubble size in chocolate?

    International Nuclear Information System (INIS)

    Watson, N; Hazlehurst, T; Povey, M; Vieira, J; Sundara, R; Sandoz, J-P

    2014-01-01

    Aerated chocolate products consist of solid chocolate with the inclusion of bubbles and are a popular consumer product in many countries. The volume fraction and size distribution of the bubbles has an effect on their sensory properties and manufacturing cost. For these reasons it is important to have an online real time process monitoring system capable of measuring their bubble size distribution. As these products are eaten by consumers it is desirable that the monitoring system is non contact to avoid food contaminations. In this work we assess the feasibility of using an airborne ultrasound system to monitor the bubble size distribution in aerated chocolate bars. The experimental results from the airborne acoustic experiments were compared with theoretical results for known bubble size distributions using COMSOL Multiphysics. This combined experimental and theoretical approach is used to develop a greater understanding of how ultrasound propagates through aerated chocolate and to assess the feasibility of using airborne ultrasound to monitor bubble size distribution in these systems. The results indicated that a smaller bubble size distribution would result in an increase in attenuation through the product

  15. Can airborne ultrasound monitor bubble size in chocolate?

    Science.gov (United States)

    Watson, N.; Hazlehurst, T.; Povey, M.; Vieira, J.; Sundara, R.; Sandoz, J.-P.

    2014-04-01

    Aerated chocolate products consist of solid chocolate with the inclusion of bubbles and are a popular consumer product in many countries. The volume fraction and size distribution of the bubbles has an effect on their sensory properties and manufacturing cost. For these reasons it is important to have an online real time process monitoring system capable of measuring their bubble size distribution. As these products are eaten by consumers it is desirable that the monitoring system is non contact to avoid food contaminations. In this work we assess the feasibility of using an airborne ultrasound system to monitor the bubble size distribution in aerated chocolate bars. The experimental results from the airborne acoustic experiments were compared with theoretical results for known bubble size distributions using COMSOL Multiphysics. This combined experimental and theoretical approach is used to develop a greater understanding of how ultrasound propagates through aerated chocolate and to assess the feasibility of using airborne ultrasound to monitor bubble size distribution in these systems. The results indicated that a smaller bubble size distribution would result in an increase in attenuation through the product.

  16. THREE-DIMENSIONAL MAGNETOHYDRODYNAMIC SIMULATIONS OF BUOYANT BUBBLES IN GALAXY CLUSTERS

    International Nuclear Information System (INIS)

    O'Neill, S. M.; De Young, D. S.; Jones, T. W.

    2009-01-01

    We report results of three-dimensional magnetohydrodynamic simulations of the dynamics of buoyant bubbles in magnetized galaxy cluster media. The simulations are three-dimensional extensions of two-dimensional calculations reported by Jones and De Young. Initially, spherical bubbles and briefly inflated spherical bubbles all with radii a few times smaller than the intracluster medium (ICM) scale height were followed as they rose through several ICM scale heights. Such bubbles quickly evolve into a toroidal form that, in the absence of magnetic influences, is stable against fragmentation in our simulations. This ring formation results from (commonly used) initial conditions that cause ICM material below the bubbles to drive upwards through the bubble, creating a vortex ring; that is, hydrostatic bubbles develop into 'smoke rings', if they are initially not very much smaller or very much larger than the ICM scale height. Even modest ICM magnetic fields with β = P gas /P mag ∼ 3 can influence the dynamics of the bubbles, provided the fields are not tangled on scales comparable to or smaller than the size of the bubbles. Quasi-uniform, horizontal fields with initial β ∼ 10 2 bifurcated our bubbles before they rose more than about a scale height of the ICM, and substantially weaker fields produced clear distortions. These behaviors resulted from stretching and amplification of ICM fields trapped in irregularities along the top surface of the young bubbles. On the other hand, tangled magnetic fields with similar, modest strengths are generally less easily amplified by the bubble motions and are thus less influential in bubble evolution. Inclusion of a comparably strong, tangled magnetic field inside the initial bubbles had little effect on our bubble evolution, since those fields were quickly diminished through expansion of the bubble and reconnection of the initial field.

  17. Gas transport into a cavitation bubble during the explosion

    International Nuclear Information System (INIS)

    Oldenziel, D.M.

    1976-01-01

    When considering cavitation bubbles exploding from small stream nuclei the surface tension plays an important role, and mostly negative pressures exist in the surroundings of such a bubble. During the short explosion time, the gas and vapor pressure in the bubble plays no important role in the dynamic process. The high radial velocity of the bubble wall introduces a steep gradient in the concentration of dissolved air near it, which results in some enforced gas transport into the bubble. During the bubble implosion it is necessary to take into account the amount of gas in the bubble, as it certainly plays an important role in exploring the cavitation erosion. In this survey the solution of a mathematical model for the gas diffusion process is compared with some experimental results

  18. Fluctuation effects on bubble growth in hot nuclear matter

    International Nuclear Information System (INIS)

    Santiago, A.J.; Chung, K.C.

    1991-01-01

    The evolution of bubbles with arbitrary density in an infinite nuclear system is studied in a simplified treatment. Kinetic pressure fluctuations on the bubble surface are considered. The critical radius, evolution time and probability for bubble expansion are shown to depend significantly on the initial bubble density. (author)

  19. Dynamics of diffusive bubble growth and pressure recovery in a bubbly rhyolitic melt embedded in an elastic solid

    Science.gov (United States)

    Chouet, Bernard A.; Dawson, Phillip B.; Nakano, Masaru

    2006-01-01

    We present a model of gas exsolution and bubble expansion in a melt supersaturated in response to a sudden pressure drop. In our model, the melt contains a suspension of gas bubbles of identical sizes and is encased in a penny-shaped crack embedded in an elastic solid. The suspension is modeled as a three-dimensional lattice of spherical cells with slight overlap, where each elementary cell consists of a gas bubble surrounded by a shell of volatile-rich melt. The melt is then subjected to a step drop in pressure, which induces gas exsolution and bubble expansion, resulting in the compression of the melt and volumetric expansion of the crack. The dynamics of diffusion-driven bubble growth and volumetric crack expansion span 9 decades in time. The model demonstrates that the speed of the crack response depends strongly on volatile diffusivity in the melt and bubble number density and is markedly sensitive to the ratio of crack thickness to crack radius and initial bubble radius but is relatively insensitive to melt viscosity. The net drop in gas concentration in the melt after pressure recovery represents only a small fraction of the initial concentration prior to the drop, suggesting the melt may undergo numerous pressure transients before becoming significantly depleted of gases. The magnitude of pressure and volume recovery in the crack depends sensitively on the size of the input-pressure transient, becoming relatively larger for smaller-size transients in a melt containing bubbles with initial radii less than 10-5 m. Amplification of the input transient may be large enough to disrupt the crack wall and induce brittle failure in the rock matrix surrounding the crack. Our results provide additional basis for the interpretation of volume changes in the magma conduit under Popocatépetl Volcano during Vulcanian degassing bursts in its eruptive activity in April–May 2000.

  20. Venous injury in abusive head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Choudhary, Arabinda K. [Nemours A. I. duPont Hospital for Children, Department of Radiology, Wilmington, DE (United States); Bradford, Ray; Thamburaj, K.; Boal, Danielle K.B. [Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Dias, Mark S. [Hershey Medical Center, Department of Neurosurgery, Hershey, PA (United States)

    2015-11-15

    Abusive head trauma (AHT) is an important cause of serious brain injury in infants and young children who have characteristic clinical and imaging findings that are discordant with the clinical history provided. Recent attention has focused on abnormalities of the cranial venous sinuses and cortical veins, both on MRI and at autopsy. Although many have interpreted these to be secondary to the AHT, some have recently argued that these venous abnormalities represent primary cortical sinus and venous thrombosis that leads secondarily to subdural hemorrhage and secondary brain injury. Direct trauma to the veins and sinuses has been reported at autopsy in AHT, but there has been no systematic study of venous abnormalities in cases of AHT. The purpose of this study was to define the incidence and characteristics of venous and sinus abnormalities in AHT. We included all children <36 months of age who were diagnosed with abusive head trauma between 2001 and 2012 and who had MRI and magnetic resonance (MR) venography as part of their diagnostic workup. We analyzed age, gender and clinical findings. MRI and MR venography were analyzed independently by two neuroradiologists with a focus on abnormalities involving the intracranial veins and venous sinuses. A total of 45 children were included. The median age was 3 months (range 15 days to 31 months) and 28 were boys (62%). Clinical findings included retinal hemorrhage in 71% and extracranial fractures in 55%. CT or MRI demonstrated subdural hemorrhage in 41 (91%); none had subdural effusions. In 31 cases (69%) MR venography demonstrated mass effect on the venous sinuses or cortical draining veins, with either displacement or partial or complete effacement of the venous structures from an adjacent subdural hematoma or brain swelling. We also describe the lollipop sign, which represents direct trauma to the cortical bridging veins and was present in 20/45 (44%) children. Evidence of displacement or compression of cortical veins

  1. Venous injury in abusive head trauma

    International Nuclear Information System (INIS)

    Choudhary, Arabinda K.; Bradford, Ray; Thamburaj, K.; Boal, Danielle K.B.; Dias, Mark S.

    2015-01-01

    Abusive head trauma (AHT) is an important cause of serious brain injury in infants and young children who have characteristic clinical and imaging findings that are discordant with the clinical history provided. Recent attention has focused on abnormalities of the cranial venous sinuses and cortical veins, both on MRI and at autopsy. Although many have interpreted these to be secondary to the AHT, some have recently argued that these venous abnormalities represent primary cortical sinus and venous thrombosis that leads secondarily to subdural hemorrhage and secondary brain injury. Direct trauma to the veins and sinuses has been reported at autopsy in AHT, but there has been no systematic study of venous abnormalities in cases of AHT. The purpose of this study was to define the incidence and characteristics of venous and sinus abnormalities in AHT. We included all children <36 months of age who were diagnosed with abusive head trauma between 2001 and 2012 and who had MRI and magnetic resonance (MR) venography as part of their diagnostic workup. We analyzed age, gender and clinical findings. MRI and MR venography were analyzed independently by two neuroradiologists with a focus on abnormalities involving the intracranial veins and venous sinuses. A total of 45 children were included. The median age was 3 months (range 15 days to 31 months) and 28 were boys (62%). Clinical findings included retinal hemorrhage in 71% and extracranial fractures in 55%. CT or MRI demonstrated subdural hemorrhage in 41 (91%); none had subdural effusions. In 31 cases (69%) MR venography demonstrated mass effect on the venous sinuses or cortical draining veins, with either displacement or partial or complete effacement of the venous structures from an adjacent subdural hematoma or brain swelling. We also describe the lollipop sign, which represents direct trauma to the cortical bridging veins and was present in 20/45 (44%) children. Evidence of displacement or compression of cortical veins

  2. Erythrocytes and von Willebrand factor in venous thrombosis

    NARCIS (Netherlands)

    Smeets, M.W.J.

    2018-01-01

    Venous thromboembolism represents the third leading vascular disease after myocardial infarction and stroke. Erythrocytes, the most abundant cells in venous thrombi, were thought to be innocent bystanders that become tangled up in the fibrin mesh of venous thrombi. However, this thesis describes

  3. Energy cascading by triple-bubble interactions via time-delayed control

    International Nuclear Information System (INIS)

    Lin, Yen-Liang; Chang, Chia-Ming; Tseng, Fan-Gang; Yang, I-Da; Chieng, Ching-Chang

    2012-01-01

    The triple-bubble interaction controlled by a precise time-delayed technique was investigated in detail with respect to different ignition times, heater spaces and sequential firing modes to promote efficient energy cascading and concentration. The target bubble, which was generated under a specific delay time with two auxiliary bubbles, can have a volume that is two or almost three times larger than that of a single bubble. This result overcomes the limitation of energy usage on an explosive microbubble under a constant heat flux. As the heater space decreases, stronger bubble–bubble interactions were obtained due to the hydrodynamic effect and the intensive pressure wave emission, resulting in highly enhancing and depressing bubble dynamics. Other interesting phenomena, such as bubble shifting, mushroom-shape bubble, rod-shape bubble and bubble extension among heaters, were also recorded by a high-speed phase-averaged stroboscopic technique, displaying special non-spherical bubble dynamics. Artificial manipulation of bubble behavior was further conducted in a two-level sequential firing process. Using various volumetric combinations, the adjustable multi-level fluid transportation can be realized by a digital time-delayed control. The above-mentioned information can be applied to not only the design and operation of inkjet printheads but also cavitation research and fluid pumping in microdevices. (paper)

  4. Comparative analysis of top-lit bubble column and gas-lift bioreactors for microalgae-sourced biodiesel production

    International Nuclear Information System (INIS)

    Seyed Hosseini, Nekoo; Shang, Helen; Ross, Gregory M.; Scott, John Ashley

    2016-01-01

    Highlights: • Top-lit gas-lift and bubble columns were studied as deep algal cultivation tank. • A theoretical energy requirement analysis and a hydrodynamic model were developed. • Areal productivities of both bioreactors were notably higher than traditional raceways. • A gas-lift reactor sparged with 6% carbon dioxide achieved the highest lipid production. • Hydrodynamic and light stresses increased the lipid content suitable for biodiesel. - Abstract: The development of top-lit one-meter deep bioreactors operated as either a gas-lift or bubble column system using air and carbon dioxide enriched air was studied. The goal was high productivity cultivation of algae with elevated lipid levels suitable for conversion into biodiesel. A theoretical energy requirement analysis and a hydrodynamic model were developed to predict liquid circulation velocities in the gas-lift bioreactor, which agreed well with experimental measurements. The influence of operational parameters such as design of bioreactor, gas flow rates and carbon dioxide concentration on the growth and lipid volumetric production of Scenedesmus dimorphus was evaluated using factorial design. While biomass productivity was 12% higher in the bubble column bioreactor (68.2 g_d_w m"−"2 day"−"1), maximum lipid volumetric production (0.19 g_L_i_p_i_d L"−"1) was found in a gas-lift bioreactor sparged with 6% carbon dioxide due to hydrodynamic and light stresses.

  5. Helium bubbles aggravated defects production in self-irradiated copper

    Science.gov (United States)

    Wu, FengChao; Zhu, YinBo; Wu, Qiang; Li, XinZhu; Wang, Pei; Wu, HengAn

    2017-12-01

    Under the environment of high radiation, materials used in fission and fusion reactors will internally accumulate numerous lattice defects and bubbles. With extensive studies focused on bubble resolution under irradiation, the mutually effects between helium bubbles and displacement cascades in irradiated materials remain unaddressed. Therefore, the defects production and microstructure evolution under self-irradiation events in vicinity of helium bubbles are investigated by preforming large scale molecular dynamics simulations in single-crystal copper. When subjected to displacement cascades, distinguished bubble resolution categories dependent on bubble size are observed. With the existence of bubbles, radiation damage is aggravated with the increasing bubble size, represented as the promotion of point defects and dislocations. The atomic mechanisms of heterogeneous dislocation structures are attributed to different helium-vacancy cluster modes, transforming from the resolved gas trapped with vacancies to the biased absorption of vacancies by the over-pressured bubble. In both cases, helium impedes the recombination of point defects, leading to the accelerated formation of interstitial loops. The results and insight obtained here might contribute to understand the underlying mechanism of transmutant solute on the long-term evolution of irradiated materials.

  6. Optical measurement of bubbles: System design and application

    NARCIS (Netherlands)

    Leifer, I.; Leeuw, G.de; Cohen, L.H.

    2003-01-01

    Affordable high quality charge-coupled device (CCD) video cameras and image processing software are powerful tools for bubble measurements. Because of the wide variation between bubble populations, different bubble measurement systems (BMSs) are required depending upon the application. Two BMSs are

  7. Neutron Imaging study of bubble behaviors in Nanofluid Through Engineered Orifices

    International Nuclear Information System (INIS)

    Seo, Seok Bin; Bang, In Cheol; Kim, Tae Joo

    2014-01-01

    Most studies focused on the change of surface parameters through deposited nanoparticles, while Vafaei and Wen firstly discussed modification of bubble dynamics by dispersed nanoparticles in fluid as well as deposited ones. The boiling mechanism, as an effective heat transfer mode, includes bubble generation, growth, departure, and coalescence. Therefore the change of bubble dynamics can lead to the change of boiling heat transfer condition. That is, not only surface characteristics but the dispersed nanoparticles would be the essential parameters of boiling mechanism in terms of bubble dynamics. For advanced visualization of opaque fluids, the neutron imaging technique is introduced. In the present study, the bubble dynamics in nanofluid through engineered orifices was studied. The main parameters of engineered orifices are size and geometry. Photographic analysis of bubble departure frequency and averaged bubble departure volume provides as follows: With increasing orifice diameter, averaged bubble departure volume increases, while bubble departure frequency decreases. The results are attributed to enhanced capillary force by increasing contact perimeter. Averaged bubble departure volume and bubble departure frequency remain similar for three different types of orifices. But edges of the triangle and square orifice produce small bubbles which interrupts bubble generation. The converged triple contact line due to the edge may be a reason for the emerged baby bubbles. Nanofluid shows less averaged bubble departure volume and higher bubble departure frequency. Considering little change in physical properties of the fluid, interaction between bubble interface and nanoparticles may be in charge of the results

  8. Bubble Dynamics in Laser Lithotripsy

    International Nuclear Information System (INIS)

    Mohammadzadeh, Milad; Mercado, Julian Martinez; Ohl, Claus-Dieter

    2015-01-01

    Laser lithotripsy is a medical procedure for fragmentation of urinary stones with a fiber guided laser pulse of several hundred microseconds long. Using high-speed photography, we present an in-vitro study of bubble dynamics and stone motion induced by Ho:YAG laser lithotripsy. The experiments reveal that detectable stone motion starts only after the bubble collapse, which we relate with the collapse-induced liquid flow. Additionally, we model the bubble formation and dynamics using a set of 2D Rayleigh-Plesset equations with the measured laser pulse profile as an input. The aim is to reduce stone motion through modification of the temporal laser pulse profile, which affects the collapse scenario and consequently the remnant liquid motion. (paper)

  9. 'Chronic cerebrospinal venous insufficiency' in multiple sclerosis. Is multiple sclerosis a disease of the cerebrospinal venous outflow system?

    International Nuclear Information System (INIS)

    Wattjes, M.P.; Doepp, F.; Bendszus, M.; Fiehler, J.

    2011-01-01

    Chronic impaired venous outflow from the central nervous system has recently been claimed to be associated with multiple sclerosis (MS) pathology. This resulted in the term chronic cerebrospinal venous insufficiency (CCSVI) in MS. The concept of CCSVI is based on sonography studies showing that impaired venous outflow leading to pathological reflux is almost exclusively present in MS patients but not in healthy controls. Based on these findings, a new pathophysiological concept has been introduced suggesting that chronic venous outflow obstruction and venous reflux in the CNS result in pathological iron depositions leading to inflammation and neurodegeneration. The theory of CCSVI in MS has rapidly generated tremendous interest in the media and among patients and the scientific community. In particular, the potential shift in treatment concepts possibly leading to an interventional treatment approach including balloon angioplasty and venous stent placement is currently being debated. However, results from recent studies involving several imaging modalities have raised substantial concerns regarding the CCSVI concept in MS. In this review article, we explain the concept of CCSVI in MS and discuss this hypothesis in the context of MS pathophysiology and imaging studies which have tried to reproduce or refute this theory. In addition, we draw some major conclusions focusing in particular on the crucial question as to whether interventional treatment options are expedient. In conclusion, the present conclusive data confuting the theory of CCSVI in MS should lead to reluctance with respect to the interventional treatment of possible venous anomalies in MS patients. (orig.)

  10. Turbulence modulation induced by bubble swarm in oscillating-grid turbulence

    International Nuclear Information System (INIS)

    Morikawa, Koichi; Urano, Shigeyuki; Saito, Takayuki

    2007-01-01

    In the present study, liquid-phase turbulence modulation induced by a bubble swarm ascending in arbitrary turbulence was experimentally investigated. Liquid-phase homogeneous isotropic turbulence was formed using an oscillating grid in a cylindrical acrylic vessel of 149 mm in inner diameter. A bubble swarm consisting of 19 bubbles of 2.8 mm in equivalent diameter was examined; the bubble size and launching time were completely controlled using a bubble launching device through audio speakers. This bubble launching device was able to repeatedly control the bubble swarm arbitrarily and precisely. The bubble swarm was launched at a frequency of 4 Hz. The liquid phase motion was measured via two LDA (Laser Doppler Anemometer) probes. The turbulence intensity, spatial correlation and integral scale were calculated from LDA data obtained by the two spatially-separate-point measurement. When the bubble swarm was added, the turbulence intensity dramatically changed. The original isotropic turbulence was modulated to the anisotropic turbulence by the mutual interference between the bubble swarm and ambient isotropic turbulence. The integral scales were calculated from the spatial correlation function. The effects of the bubble swarm on the integral scales showed the tendencies similar to those on turbulence intensity. (author)

  11. Beer tapping: dynamics of bubbles after impact

    Science.gov (United States)

    Mantič-Lugo, V.; Cayron, A.; Brun, P.-T.; Gallaire, F.

    2015-12-01

    Beer tapping is a well known prank where a bottle of beer is impacted from the top by a solid object, usually another bottle, leading to a sudden foam overflow. A description of the shock-driven bubble dynamics leading to foaming is presented based on an experimental and numerical study evoking the following physical picture. First, the solid impact produces a sudden downwards acceleration of the bottle creating a strong depression in the liquid bulk. The existing bubbles undergo a strong expansion and a sudden contraction ending in their collapse and fragmentation into a large amount of small bubbles. Second, the bubble clouds present a large surface area to volume ratio, enhancing the CO2 diffusion from the supersaturated liquid, hence growing rapidly and depleting the CO2. The clouds of bubbles migrate upwards in the form of plumes pulling the surrounding liquid with them and eventually resulting in the foam overflow. The sudden pressure drop that triggers the bubble dynamics with a collapse and oscillations is modelled by the Rayleigh-Plesset equation. The bubble dynamics from impact to collapse occurs over a time (tb ≃ 800 μs) much larger than the acoustic time scale of the liquid bulk (tac = 2H/c ≃ 80 μs), for the experimental container of height H = 6 cm and a speed of sound around c ≃ 1500 m/s. This scale separation, together with the comparison of numerical and experimental results, suggests that the pressure drop is controlled by two parameters: the acceleration of the container and the distance from the bubble to the free surface.

  12. Gas Bubble Migration and Trapping in Porous Media: Pore-Scale Simulation

    Science.gov (United States)

    Mahabadi, Nariman; Zheng, Xianglei; Yun, Tae Sup; van Paassen, Leon; Jang, Jaewon

    2018-02-01

    Gas bubbles can be naturally generated or intentionally introduced in sediments. Gas bubble migration and trapping affect the rate of gas emission into the atmosphere or modify the sediment properties such as hydraulic and mechanical properties. In this study, the migration and trapping of gas bubbles are simulated using the pore-network model extracted from the 3D X-ray image of in situ sediment. Two types of bubble size distribution (mono-sized and distributed-sized cases) are used in the simulation. The spatial and statistical bubble size distribution, residual gas saturation, and hydraulic conductivity reduction due to the bubble trapping are investigated. The results show that the bubble size distribution becomes wider during the gas bubble migration due to bubble coalescence for both mono-sized and distributed-sized cases. And the trapped bubble fraction and the residual gas saturation increase as the bubble size increases. The hydraulic conductivity is reduced as a result of the gas bubble trapping. The reduction in hydraulic conductivity is apparently observed as bubble size and the number of nucleation points increase.

  13. Modeling of bubble break-up in stirred tanks

    Directory of Open Access Journals (Sweden)

    Živković Goran

    2004-01-01

    Full Text Available The Lagrangian code LAG3D for dispersed phase flow modeling was implemented with the introduction of bubble break-up model. The research was restricted on bubbles with diameter less than 2 mm, i.e. bubbles which could be treated as spheres. The model was developed according to the approach of Martinez-Bazan model. It was rearranged and adjusted for the use in the particular problem of flow in stirred tanks. Developed model is stochastic one, based on the assumption that shear in the flow induces the break of the bubble. As a dominant parameter a dissipation of the turbulent kinetic energy was used. Computations were performed for two different types of the stirrer: Rushton turbine, and Pitch blade turbine. The geometry of the tank was kept constant (four blades. Two different types of liquids with very big difference in viscosity were used, i.e. silicon oil and dimethylsulfoxide, in order to enable computation of the flow in turbulent regime as well. As a parameter of the flow, the number of rotations of the stirrer was varying. As a result of the computation the fields of velocity of both phases were got, as well as the fields of bubble concentration bubble mean diameter and bubble Sauter diameter. To estimate the influence of the break-up model on the processes in the stirred tank a computations with and without this model were performed and compared. A considerable differences were found not only in the field of bubble diameter, but also in the field of bubble concentration. That confirmed a necessity of the introduction of such model. A comparison with the experiments performed with phase Doppler anemometry technique showed very good agreement in velocity and concentration profiles of the gas phase. The results for the average bubble diameter are qualitatively the same, but in almost all computations about 20% smaller bubble diameter was got than in the measurements.

  14. Preparation of bubble damage detectors

    International Nuclear Information System (INIS)

    Tu Caiqing; Guo Shilun; Wang Yulan; Hao Xiuhong; Chen Changmao; Su Jingling

    1997-01-01

    Bubble damage detectors have been prepared by using polyacrylamide as detector solid and freon as detector liquid. Tests show that the prepared detectors are sensitive to fast neutrons and have proportionality between bubble number and neutron fluence within a certain range of neutron fluence. Therefore, it can be used as a fast neutron detector and a dosimeter

  15. Bubble chamber: colour enhanced tracks

    CERN Multimedia

    1998-01-01

    This artistically-enhanced image of real particle tracks was produced in the Big European Bubble Chamber (BEBC). Liquid hydrogen is used to create bubbles along the paths of the particles as a piston expands the medium. A magnetic field is produced in the detector causing the particles to travel in spirals, allowing charge and momentum to be measured.

  16. Intensely oscillating cavitation bubble in microfluidics

    International Nuclear Information System (INIS)

    Siew-Wan, Ohl; Tandiono; Klaseboer, Evert; Dave, Ow; Choo, Andre; Claus-Dieter, Ohl

    2015-01-01

    This study reports the technical breakthrough in generating intense ultrasonic cavitation in the confinement of a microfluidics channel [1], and applications that has been developed on this platform for the past few years [2,3,4,5]. Our system consists of circular disc transducers (10-20 mm in diameter), the microfluidics channels on PDMS (polydimethylsiloxane), and a driving circuitry. The cavitation bubbles are created at the gas- water interface due to strong capillary waves which are generated when the system is driven at its natural frequency (around 100 kHz) [1]. These bubbles oscillate and collapse within the channel. The bubbles are useful for sonochemistry and the generation of sonoluminescence [2]. When we add bacteria (Escherichia coli), and yeast cells (Pichia pastoris) into the microfluidics channels, the oscillating and collapsing bubbles stretch and lyse these cells [3]. Furthermore, the system is effective (DNA of the harvested intracellular content remains largely intact), and efficient (yield reaches saturation in less than 1 second). In another application, human red blood cells are added to a microchamber. Cell stretching and rapture are observed when a laser generated cavitation bubble expands and collapses next to the cell [4]. A numerical model of a liquid pocket surrounded by a membrane with surface tension which was placed next to an oscillating bubble was developed using the Boundary Element Method. The simulation results showed that the stretching of the liquid pocket occurs only when the surface tension is within a certain range. (paper)

  17. Laser controllable generation and manipulation of micro-bubbles in water

    Science.gov (United States)

    Angelsky, O. V.; Bekshaev, A. Ya.; Maksimyak, P. P.; Maksimyak, A. P.; Hanson, S. G.; Kontush, S. M.

    2018-01-01

    Micrometer-sized vapor bubbles are formed due to local heating of the water suspension containing absorptive pigment particles of 100 nm diameter. The heating is performed by the CW near-infrared laser radiation. By changing the laser power, four regimes are realized: (1) bubble generation, (2) stable growth of the existing bubbles; (3) stationary existence of the bubbles and (4) bubbles' shrinkage and collapse. The generation and evolution of single bubbles and ensembles of bubbles with controllable sizes and numbers is demonstrated. The bubbles are grouped within the laserilluminated region. They can be easily moved and transported together with the focal spot. The results can be useful for applications associated with the precise manipulation and the species delivery in nano- and micro-engineering problems.

  18. VENOUS INSUFFICIENCY AND THROMBOEMBOLIC DISEASE IN BARIATRIC SURGERY PATIENTS

    Directory of Open Access Journals (Sweden)

    Bonno van BELLEN

    2013-09-01

    Full Text Available Context Morbid obesity is associated with various co-morbidities, including chronic venous insufficiency. Bariatric surgery is the only effective treatment for morbid obesity, but with potential risks and possible complications, including venous thromboembolism. Objective To determine the prevalence of clinical and ultrasonographic signs of chronic venous insufficiency in morbid obese patients in preparation for bariatric surgery and the incidence of post-operative venous thromboembolic disease. Methods Patients on work-up for bariatric surgery of Centro Terapêutico Especializado em Fígado (CETEFI and Pro-Gastro surgical teams of the Hospital Beneficência Portuguesa de São Paulo were included. The analysed data were pre-operative findings for venous insufficiency (CEAP - clinical, etiological, anatomical, physiopathologic - classification and venous ultrassonographic findings, type of surgery (open or laparoscopic, abdominal circumference, body mass index (BMI and post-operative ultrassonography search for venous insufficiency and deep venous thrombosis. Results Between March 2007 and December 2009, 95 patients candidates for bariatric surgery had clinical and duplex scan evaluation of the lower limbs venous system. Of the 95 patients, 53 were submitted to the surgical procedure. There was a predominance of women (77.9%, the average age was 38.5 years, average preoperative weight 124.6 kg and average BMI of 45.5 kg/m2. Regarding obesity, 16.8% were obese, and 83.1% were morbidly obese. In relation to the venous findings, 86.3% of the patients did fit CEAP classification less than 3 and 13.7% greater than or equal to 3. Among the post-operative complications, there were four cases of wound infection. Three patients developed post-operative distal venous thrombosis (7.5%, but no one had clinically manifested pulmonary embolism. Conclusion No relation between BMI, CEAP classification and venous ultrassonographic findings were found. Although

  19. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  20. Venous anomalies and abnormalities of the posterior fossa

    International Nuclear Information System (INIS)

    Goulao, A.; Alvarez, H.; Garcia Monaco, R.; Pruvost, P.; Lasjaunias, P.

    1990-01-01

    The authors report a series of 16 patients with venous anomalies or abnormalities of the posterior fossa studied by angiography, CT and/or MRI. We believe that so-called 'venous angioma' are extreme anatomic variants that drain normal territories, and we prefer to call them developmental venous anomalies (DVA). Posterior fossa DVA, like the supra-tentorial ones are classified according to their drainage into deep and superficial type. They are exclusively located in the cerebellum or tectum. In 4 cases DVA was an incidental finding, in 3 an associated cerebral venous malformation (CVM) was found and felt to be the cause of the symptoms and only in one (Trigeminal pain) was a link between both suspected. Cavernous venous malformation (CVM) were found in frequent association with DVA (27%). 4 cases were single and 2 multiple. 5 CVM were located in the brain stem and 3 in the cerebellum. The clinical and radiological files were reviewed and a direct relationship between symptoms and localization was found in all patients with CVM. In 2 cases venous dysplasia was found: 1 Sturge-Weber and 1 First branchial arch syndrome. Both posterior fossa venous abnormalities were incidental findings. (orig.)

  1. Hepatic venous pressure gradients measured by duplex ultrasound

    International Nuclear Information System (INIS)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M.

    2002-01-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P -2 provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  2. Inertial manipulation of bubbles in rectangular microfluidic channels.

    Science.gov (United States)

    Hadikhani, Pooria; Hashemi, S Mohammad H; Balestra, Gioele; Zhu, Lailai; Modestino, Miguel A; Gallaire, François; Psaltis, Demetri

    2018-03-27

    Inertial microfluidics is an active field of research that deals with crossflow positioning of the suspended entities in microflows. Until now, the majority of the studies have focused on the behavior of rigid particles in order to provide guidelines for microfluidic applications such as sorting and filtering. Deformable entities such as bubbles and droplets are considered in fewer studies despite their importance in multiphase microflows. In this paper, we show that the trajectory of bubbles flowing in rectangular and square microchannels can be controlled by tuning the balance of forces acting on them. A T-junction geometry is employed to introduce bubbles into a microchannel and analyze their lateral equilibrium position in a range of Reynolds (1 < Re < 40) and capillary numbers (0.1 < Ca < 1). We find that the Reynolds number (Re), the capillary number (Ca), the diameter of the bubble (D[combining macron]), and the aspect ratio of the channel are the influential parameters in this phenomenon. For instance, at high Re, the flow pushes the bubble towards the wall while large Ca or D[combining macron] moves the bubble towards the center. Moreover, in the shallow channels, having aspect ratios higher than one, the bubble moves towards the narrower sidewalls. One important outcome of this study is that the equilibrium position of bubbles in rectangular channels is different from that of solid particles. The experimental observations are in good agreement with the performed numerical simulations and provide insights into the dynamics of bubbles in laminar flows which can be utilized in the design of flow based multiphase flow reactors.

  3. Structure of positive streamers inside gaseous bubbles immersed in liquids

    International Nuclear Information System (INIS)

    Babaeva, Natalia Yu; Kushner, Mark J

    2009-01-01

    Electric discharges and streamers in liquids typically proceed through vapour phase channels produced by the streamer or in gaseous bubbles. The bubbles can originate by enthalpy changes produced by the discharge or can be artificially injected into the liquid. Experiments on streamers in bubbles immersed in liquids have shown that the discharge propagates either along the surface of the bubble or through the volume of the bubble as in conventional streamer propagation in air. In this paper we report on results of a computational investigation of streamer propagation through bubbles immersed in liquids. We found that the dielectric constant of the liquid in large part determines the path the streamer takes. Streamers in bubbles immersed in a liquid with a high permittivity preferentially propagate along the surface of the bubble. Liquids with low permittivity can result in the streamer propagating along the axis of the bubble. The permittivity at which this transition occurs is a function of the applied voltage, size of the bubble and the conductivity of the liquid. (fast track communication)

  4. Expansion of a vapor bubble and aerosols transfer

    International Nuclear Information System (INIS)

    Breton, J.P.; Lapicore, A.; Porrachia, A.; Natta, M.; Amblard, M.; Berthoud, G.

    1979-08-01

    Experimental results on the expansion and collapse of two phase vapor bubble, and on the aerosols transport outside the tank are presented. Two facilities using small source of hot water (2 cm 3 ) or bigger ones (1000 cm 3 ) were used and are described. Two models are developped to analyze the results on the bubble. They show the heat and mass transfer from the bubble to the surroundings and the following reduction in the mechanical energy delivered by the bubble, and the decrease in this reduction due to noncondensables and to scale effect. The models developed or the aerosol transfer show that most particles are likely transported from the bubble to the cover gas

  5. Bubbles generated from wind-steepened breaking waves: 2. Bubble plumes, bubbles, and wave characteristics

    NARCIS (Netherlands)

    Leifer, I.; Caulliez, G.; Leeuw, G.de

    2006-01-01

    Measurements of breaking-wave-generated bubble plumes were made in fresh (but not clean) water in a large wind-wave tunnel. To preserve diversity, a classification scheme was developed on the basis of plume dimensions and "optical density," or the plume's ability to obscure the background. Optically

  6. Simulation of a bubbling fluidized bed process for capturing CO2 from flue gas

    International Nuclear Information System (INIS)

    Choi, Jeong-Hoo; Yi, Chang-Keun; Jo, Sung-Ho; Ryu, Ho-Jung; Park, Young-Cheol

    2014-01-01

    We simulated a bubbling bed process capturing CO 2 from flue gas. It applied for a laboratory scale process to investigate effects of operating parameters on capture efficiency. The adsorber temperature had a stronger effect than the regenerator temperature. The effect of regenerator temperature was minor for high adsorber temperature. The effect of regenerator temperature decreased to level off for the temperature >250 .deg. C. The capture efficiency was rather dominated by the adsorption reaction than the regeneration reaction. The effect of gas velocity was as appreciable as that of adsorber temperature. The capture efficiency increased with the solids circulation rate since it was ruled by the molar ratio of K to CO 2 for solids circulation smaller than the minimum required one (G s, min ). However, it leveled off for solids circulation rate >G s, min . As the ratio of adsorber solids inventory to the total solids inventory (x w1 ) increased, the capture efficiency increased until x w1 =0.705, but decreased for x w1 >0.705 because the regeneration time decreased too small. It revealed that the regeneration reaction was faster than the adsorption reaction. Increase of total solids inventory is a good way to get further increase in capture efficiency

  7. Bubble coalescence dynamics and supersaturation in electrolytic gas evolution

    Energy Technology Data Exchange (ETDEWEB)

    Stover, R.L. [Univ. of California, Berkeley, CA (United States). Dept. of Chemical Engineering]|[Lawrence Berkeley National Lab., CA (United States). Energy and Environment Div.

    1996-08-01

    The apparatus and procedures developed in this research permit the observation of electrolytic bubble coalescence, which heretofore has not been possible. The influence of bubble size, electrolyte viscosity, surface tension, gas type, and pH on bubble coalescence was examined. The Navier-Stokes equations with free surface boundary conditions were solved numerically for the full range of experimental variables that were examined. Based on this study, the following mechanism for bubble coalescence emerges: when two gas bubbles coalesce, the surface energy decreases as the curvature and surface area of the resultant bubble decrease, and the energy is imparted into the surrounding liquid. The initial motion is driven by the surface tension and slowed by the inertia and viscosity of the surrounding fluid. The initial velocity of the interface is approximately proportional to the square root of the surface tension and inversely proportional to the square root of the bubble radius. Fluid inertia sustains the oblate/prolate oscillations of the resultant bubble. The period of the oscillations varies with the bubble radius raised to the 3/2 power and inversely with the square root of the surface tension. Viscous resistance dampens the oscillations at a rate proportional to the viscosity and inversely proportional to the square of the bubble radius. The numerical simulations were consistent with most of the experimental results. The differences between the computed and measured saddle point decelerations and periods suggest that the surface tension in the experiments may have changed during each run. By adjusting the surface tension in the simulation, a good fit was obtained for the 150-{micro}m diameter bubbles. The simulations fit the experiments on larger bubbles with very little adjustment of surface tension. A more focused analysis should be done to elucidate the phenomena that occur in the receding liquid film immediately following rupture.

  8. Air bubble migration is a random event post embryo transfer.

    Science.gov (United States)

    Confino, E; Zhang, J; Risquez, F

    2007-06-01

    Air bubble location following embryo transfer (ET) is the presumable placement spot of embryos. The purpose of this study was to document endometrial air bubble position and migration following embryo transfer. Multicenter prospective case study. Eighty-eight embryo transfers were performed under abdominal ultrasound guidance in two countries by two authors. A single or double air bubble was loaded with the embryos using a soft, coaxial, end opened catheters. The embryos were slowly injected 10-20 mm from the fundus. Air bubble position was recorded immediately, 30 minutes later and when the patient stood up. Bubble marker location analysis revealed a random distribution without visible gravity effect when the patients stood up. The bubble markers demonstrated splitting, moving in all directions and dispersion. Air bubbles move and split frequently post ET with the patient in the horizontal position, suggestive of active uterine contractions. Bubble migration analysis supports a rather random movement of the bubbles and possibly the embryos. Standing up changed somewhat bubble configuration and distribution in the uterine cavity. Gravity related bubble motion was uncommon, suggesting that horizontal rest post ET may not be necessary. This report challenges the common belief that a very accurate ultrasound guided embryo placement is mandatory. The very random bubble movement observed in this two-center study suggests that a large "window" of embryo placement maybe present.

  9. Can we use volatility to diagnose financial bubbles? lessons from 40historical bubbles

    Directory of Open Access Journals (Sweden)

    Didier Sornette

    2018-03-01

    Full Text Available We inspect the price volatility before, during, and after financial asset bubbles in orderto uncover possible commonalities and check empirically whether volatility might be used as anindicator or an early warning signal of an unsustainable price increase and the associated crash. Someresearchers and finance practitioners believe that historical and/or implied volatility increase beforea crash, but we do not see this as a consistent behavior. We examine forty well-known bubbles and,using creative graphical representations to capture robustly the transient dynamics of the volatility, findthat the dynamics of the volatility would not have been a useful predictor of the subsequent crashes.In approximately two-third of the studied bubbles, the crash follows a period of lower volatility,reminiscent of the idiom of a “lull before the storm”. This paradoxical behavior, from the lensesof traditional asset pricing models, further questions the general relationship between risk and return.

  10. The expression of inflammatory cytokines, TAM tyrosine kinase receptors and their ligands is upregulated in venous leg ulcer patients: a novel insight into chronic wound immunity.

    Science.gov (United States)

    Filkor, Kata; Németh, Tibor; Nagy, István; Kondorosi, Éva; Urbán, Edit; Kemény, Lajos; Szolnoky, Győző

    2016-08-01

    The systemic host defence mechanisms, especially innate immunity, in venous leg ulcer patients are poorly investigated. The aim of the current study was to measure Candida albicans killing activity and gene expressions of pro- and anti-inflammatory cytokines and innate immune response regulators, TAM receptors and ligands of peripheral blood mononuclear cells separated from 69 venous leg ulcer patients and 42 control probands. Leg ulcer patients were stratified into responder and non-responder groups on the basis of wound healing properties. No statistical differences were found in Candida killing among controls, responders and non-responders. Circulating blood mononuclear cells of patients overexpress pro-inflammatory (IL-1α, TNFα, CXCL-8) and anti-inflammatory (IL-10) cytokines as well as TAM receptors (Tyro, Axl, MerTK) and their ligands Gas6 and Protein S compared with those of control individuals. IL-1α is notably overexpressed in venous leg ulcer treatment non-responders; in contrast, Axl gene expression is robustly stronger among responders. These markers may be considered as candidates for the prediction of treatment response among venous leg ulcer patients. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  11. Experimental investigation of bubble plume structure instability

    Energy Technology Data Exchange (ETDEWEB)

    Marco Simiano; Robert Zboray; Francois de Cachard [Thermal-Hydraulics Laboratory, Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Djamel Lakehal; George Yadigaroglu [Institute of Energy Technology, Swiss Federal Institute of Technology, ETH-Zentrum/CLT, 8092 Zurich (Switzerland)

    2005-07-01

    Full text of publication follows: The hydrodynamic properties of a 3D bubble plume in a large water pool are investigated experimentally. Bubble plumes are present in various industrial processes, including chemical plants, stirred reactors, and nuclear power plants, e.g. in BWR suppression pools. In these applications, the main issue is to predict the currents induced by the bubbles in the liquid phase, and to determine the consequent mixing. Bubble plumes, especially large and unconfined ones, present strong 3D effects and a superposition of different characteristic length scales. Thus, they represent relevant test cases for assessment and verification of 3D models in thermal-hydraulic codes. Bubble plumes are often unsteady, with fluctuations in size and shape of the bubble swarm, and global movements of the plume. In this case, local time-averaged data are not sufficient to characterize the flow. Additional information regarding changes in plume shape and position is required. The effect of scale on the 3D flow structure and stability being complex, there was a need to conduct studies in a fairly large facility, closer to industrial applications. Air bubble plumes, up to 30 cm in base diameter and 2 m in height were extensively studied in a 2 m diameter water pool. Homogeneously sized bubbles were obtained using a particular injector. The main hydrodynamic parameters. i.e., gas and liquid velocities, void fraction, bubble shape and size, plume shape and position, were determined experimentally. Photographic and image processing techniques were used to characterize the bubble shape, and double-tip optical probes to measure bubble size and void fraction. Electromagnetic probes measured the recirculation velocity in the pool. Simultaneous two-phase flow particle image velocimetry (STPFPIV) in a vertical plane containing the vessel axis provided instantaneous velocity fields for both phases and therefore the relative velocity field. Video recording using two CCD

  12. Three-dimensional reacting shock–bubble interaction

    NARCIS (Netherlands)

    Diegelmann, Felix; Hickel, S.; Adams, Nikolaus A.

    2017-01-01

    We investigate a reacting shock–bubble interaction through three-dimensional numerical simulations with detailed chemistry. The convex shape of the bubble focuses the shock and generates regions of high pressure and temperature, which are sufficient to ignite the diluted stoichiometric

  13. Pulmonary venous abnormalities encountered on pre ...

    African Journals Online (AJOL)

    Multidetector computed tomography (MDCT) elegantly renders pulmonary venous anatomy. With increasing numbers of radiofrequency ablation procedures being performed, there is now a greater emphasis on pre-procedure imaging to delineate this anatomy. Pulmonary venous mapping studies can be performed with or ...

  14. A method for bubble volume calculating in vertical two-phase flow

    International Nuclear Information System (INIS)

    Wang, H Y; Dong, F

    2009-01-01

    The movement of bubble is a basic subject in gas-liquid two-phase flow research. A method for calculating bubble volume which is one of the most important characters in bubble motion research was proposed. A suit of visualized experimental device was designed and set up. Single bubble rising in stagnant liquid in a rectangular tank was studied using the high-speed video system. Bubbles generated by four orifice with different diameter (1mm, 2mm, 3mm, 4mm) were recorded respectively. Sequences of recorded high-speed images were processed by digital image processing method, such as image noise remove, binary image transform, bubble filling, and so on. then, Several parameters could be obtained from the processed image. Bubble area, equivalent diameter, bubble velocity, bubble acceleration are all indispensable in bubble volume calculating. In order to get the force balance equation, forces that work on bubble along vertical direction, including drag force, virtual mass force, buoyancy, gravity and liquid thrust, were analyzed. Finally, the bubble volume formula could be derived from the force balance equation and bubble parameters. Examples were given to shown the computing process and results. Comparison of the bubble volume calculated by geomettic method and the present method have shown the superiority of the proposed method in this paper.

  15. Experimental study of bubbly flow using image processing techniques

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Yucheng, E-mail: ycfu@vt.edu; Liu, Yang, E-mail: liu130@vt.edu

    2016-12-15

    This paper presents an experimental study of bubbly flows at relatively high void fractions using an advanced image processing method. Bubble overlapping is a common problem in such flows and the past studies often treat the overlapping bubbles as a whole, which introduces considerable measurement uncertainties. In this study, a hybrid method combining intersection point detection and watershed segmentation is used to separate the overlapping bubbles. In order to reconstruct bubbles from separated segments, a systematic procedure is developed which can preserve more features captured in the raw image compared to the simple ellipse fitting method. The distributions of void fraction, interfacial area concentration, number density and velocity are obtained from the extracted bubble information. High-speed images of air-water bubbly flows are acquired and processed for eight test runs conducted in a 30 mm × 10 mm rectangular channel. The developed image processing scheme can effectively separate overlapping bubbles and the results compare well with the measurements by the gas flow meter and double-sensor conductivity probe. The development of flows in transverse and mainstream directions are analyzed and compared with the prediction made by the one-dimensional interfacial area transport equation (IATE) and the bubble number density transport equation.

  16. Direct numerical simulation of turbulent channel flow with deformed bubbles

    International Nuclear Information System (INIS)

    Yamamoto, Yoshinobu; Kunugi, Tomoaki

    2010-01-01

    In this study, the direct numerical simulation of a fully-developed turbulent channel flow with deformed bubbles were conducted by means of the refined MARS method, turbulent Reynolds number 150, and Bubble Reynolds number 120. As the results, large-scale wake motions were observed round the bubbles. At the bubble located region, mean velocity was degreased and turbulent intensities and Reynolds shear stress were increased by the effects of the large-scale wake motions round bubbles. On the other hands, near wall region, bubbles might effect on the flow laminarlize and drag reduction. Two types of drag coefficient of bubble were estimated from the accelerated velocity of bubble and correlation equation as a function of Particle Reynolds number. Empirical correlation equation might be overestimated the drag effects in this Particle Reynolds number range. (author)

  17. ENDOVASCULAR TREATMENT FOR DISORDERS OF THE VENOUS SYSTEM

    Directory of Open Access Journals (Sweden)

    A. G. Osiev

    2015-01-01

    Full Text Available The annual rate of deep vein thrombosis in general population is from 5 to 9 cases per 10 000, whereas for venous thromboembolism (deep vein thrombosis and pulmonary embolism taken together amounts to 14 cases per 10 000. To improve longterm results of therapy for thrombosis of deep veins of the lower extremities, it is important to restore venous function and outflow. Anticoagulant therapy with low weight or non-fractionated heparin preparations remains the most widely used method of management. However, total or partial thrombosis resolution under anticoagulant treatment is achieved only in 4 and 14% of cases, respectively. Thrombolysis allows for early resorption of the thrombus by means of a minimally invasive procedure with lower risk of complication. After the venous flow is restored, the aim of treatment is to prevent damage to the venous valves, venous hypertension and repeated thrombosis with development of the post-thrombotic syndrome. Compared to anticoagulation, systemic thrombolysis has the benefit of more rapid clot resorption and less damage to the venous valve. One of its serious limitations is a high bleeding risk related to higher doses of the drug administered through a peripheral vein catheter. Therefore, selective intra-clot administration of thombolytics (direct catheter thrombolysis has been suggested as an alternative. For more effective therapy with the use of lower doses of thrombolytics, the so called pharmaco-mechanical thrombectomy has been developed. Venous stenosis hindering the venous outflow is frequently seen after direct catheter or pharmaco-mechanical thrombolysis. Angioplasty with stent placement is recommended in the cases with residual venous abnormality after successful thrombolysis and thrombectomy. 

  18. Measurement of micro Bubbles generated by a pressurized dissolution method

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, S; Tanaka, K; Tomiyama, A [Kobe University, 1-1 Rokkodai, Nada, Kobe 657-8501 (Japan); Maeda, Y; Yamaguchi, S; Ito, Y, E-mail: hosokawa@mech.kobe-u.ac.j [Panasonic Electric Works Co., Ltd., 1048 Kadoma, Osaka 571-8686 (Japan)

    2009-02-01

    Diameters of micro-bubbles are apt to range from about one mm to several-hundred mm, and therefore, it is difficult to measure a correct diameter distribution using a single measurement method. In this study, diameters of bubbles generated by a pressurized dissolution method are measured by using phase Doppler anemometry (PDA) and an image processing method, which is based on the Sobel filter and Hough transform. The diameter distribution and the Sauter mean diameter of micro bubbles are evaluated based on the diameters measured by both methods. Experiments are conducted for several mass flow rates of dissolved gas and of air bubbles entrained in the upstream of the decompression nozzle to examine effects of the entrained bubbles on bubble diameter. As a result, the following conclusions are obtained: (1) Diameter distribution of micro bubbles can be accurately measured for a wide range of diameter by using PDA and the image processing method. (2) The mean diameter of micro-bubbles generated by gasification of dissolved gas is smaller than that generated by breakup of air bubbles entrained in the upstream of the decompression nozzle. (3) The mean bubble diameter increases with the entrainment of air bubbles in the upstream of the decompression nozzle at a constant mass flow rate of dissolved gas.

  19. Measurement of micro Bubbles generated by a pressurized dissolution method

    International Nuclear Information System (INIS)

    Hosokawa, S; Tanaka, K; Tomiyama, A; Maeda, Y; Yamaguchi, S; Ito, Y

    2009-01-01

    Diameters of micro-bubbles are apt to range from about one mm to several-hundred mm, and therefore, it is difficult to measure a correct diameter distribution using a single measurement method. In this study, diameters of bubbles generated by a pressurized dissolution method are measured by using phase Doppler anemometry (PDA) and an image processing method, which is based on the Sobel filter and Hough transform. The diameter distribution and the Sauter mean diameter of micro bubbles are evaluated based on the diameters measured by both methods. Experiments are conducted for several mass flow rates of dissolved gas and of air bubbles entrained in the upstream of the decompression nozzle to examine effects of the entrained bubbles on bubble diameter. As a result, the following conclusions are obtained: (1) Diameter distribution of micro bubbles can be accurately measured for a wide range of diameter by using PDA and the image processing method. (2) The mean diameter of micro-bubbles generated by gasification of dissolved gas is smaller than that generated by breakup of air bubbles entrained in the upstream of the decompression nozzle. (3) The mean bubble diameter increases with the entrainment of air bubbles in the upstream of the decompression nozzle at a constant mass flow rate of dissolved gas.

  20. Bubble behavior in a vertical Taylor-Couette flow

    International Nuclear Information System (INIS)

    Murai, Y; Oiwa, H; Takeda, Y

    2005-01-01

    Bubble distributions organized in a vertical Taylor-Couette flow are experimentally investigated. Modification of shear stress due to bubbles is measured with a torque sensor installed on the rotating inner cylinder. The wall shear stress decreases as bubbles are injected in all the tested range of Re from 600 to 4500. The drag reduction ratio per void fraction measured in the present experiment, which indicates net gain of the drag reduction, has been evaluated. The gain was more than unity for Re 4000. The maximum gain achieved was around 10 at Re = 600, at which point the bubbles dispersed widely on the inner cylinder surface and effectively restrict momentum exchange of fluid between the two walls. The expansion of Taylor vortices in the vertical direction by the presence of bubbles was confirmed by flow visualization including particle tracking velocimetry. Such bubble behaviours interacting with Taylor vortices are discussed in detail in this paper

  1. Bubble-induced microstreaming: guiding and destroying lipid vesicles

    Science.gov (United States)

    Marmottant, Philippe; Hilgenfeldt, Sascha

    2002-11-01

    Micron-sized bubbles respond with strong oscillations when submitted to ultrasound. This has led to their use as echographic contrast enhancers. The large energy and force densities generated by the collapsing bubbles also make them non-invasive mechanical tools: Recently, it has been reported that the interaction of cavitating bubbles with nearby cells can render the latter permeable to large molecules (sonoporation), suggesting prospects for drug delivery and gene transfection. We have developed a laboratory setup that allows for a controlled study of the interaction of single microbubbles with single lipid bilayer vesicles. Substituting vesicles for cell membranes is advantageous because the mechanical properties of vesicles are well-known. Microscopic observations reveal that vesicles near a bubble follow the vivid streaming motion set up by the bubble. The vesicles "bounce" off the bubble, being periodically accelerated towards and away from it, and undergo well-defined shape deformations along their trajectory in accordance with fluid-dynamical theory. Break-up of vesicles could also be observed.

  2. Compression of the posterior fossa venous sinuses by epidural hemorrhage simulating venous sinus thrombosis: CT and MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Sumit; Ramakrishnaiah, Raghu H.; Hegde, Shilpa V.; Glasier, Charles M. [University of Arkansas for Medical Sciences, Pediatric Radiology, Little Rock, AR (United States)

    2016-01-15

    Posterior fossa dural venous sinus thrombus is a well-described complication of head trauma, especially when fracture crosses the dural sinus grooves or in association with epidural hemorrhage. We have found that post-traumatic posterior fossa epidural hematoma compressing a dural venous sinus can mimic dural venous thrombus. To discuss the CT and MRI findings of posterior fossa epidural hemorrhages simulating sinus thrombosis, to make radiologists aware of this important imaging pitfall. We describe radiologic findings in four children in whom a posterior fossa epidural hemorrhage mimicked dural venous sinus thrombus. Routine CT head and CT venography were obtained on Toshiba volume and helical CT scanners. MRI and MR venography were performed on a Philips scanner. In all cases there was medial displacement and compression of the posterior fossa dural venous sinuses without intraluminal thrombosis. The epidural hemorrhage was seen tracking along sinus grooves in the occipital bone, peeling the dura containing the sinuses from the calvarium and compressing the sinus, simulating thrombosis on axial CT views. Both venous sinus thrombosis and posterior fossa epidural hemorrhages in children are well-described complications of head trauma. Posterior fossa epidural hemorrhage can mimic a sinus thrombus by compressing and displacing the sinuses. It is important to recognize this pitfall because treatment of a suspected thrombus with anticoagulation can worsen epidural hemorrhage. (orig.)

  3. Compression of the posterior fossa venous sinuses by epidural hemorrhage simulating venous sinus thrombosis: CT and MR findings

    International Nuclear Information System (INIS)

    Singh, Sumit; Ramakrishnaiah, Raghu H.; Hegde, Shilpa V.; Glasier, Charles M.

    2016-01-01

    Posterior fossa dural venous sinus thrombus is a well-described complication of head trauma, especially when fracture crosses the dural sinus grooves or in association with epidural hemorrhage. We have found that post-traumatic posterior fossa epidural hematoma compressing a dural venous sinus can mimic dural venous thrombus. To discuss the CT and MRI findings of posterior fossa epidural hemorrhages simulating sinus thrombosis, to make radiologists aware of this important imaging pitfall. We describe radiologic findings in four children in whom a posterior fossa epidural hemorrhage mimicked dural venous sinus thrombus. Routine CT head and CT venography were obtained on Toshiba volume and helical CT scanners. MRI and MR venography were performed on a Philips scanner. In all cases there was medial displacement and compression of the posterior fossa dural venous sinuses without intraluminal thrombosis. The epidural hemorrhage was seen tracking along sinus grooves in the occipital bone, peeling the dura containing the sinuses from the calvarium and compressing the sinus, simulating thrombosis on axial CT views. Both venous sinus thrombosis and posterior fossa epidural hemorrhages in children are well-described complications of head trauma. Posterior fossa epidural hemorrhage can mimic a sinus thrombus by compressing and displacing the sinuses. It is important to recognize this pitfall because treatment of a suspected thrombus with anticoagulation can worsen epidural hemorrhage. (orig.)

  4. Luminescence from cavitation bubbles deformed in uniform pressure gradients

    Science.gov (United States)

    Supponen, Outi; Obreschkow, Danail; Kobel, Philippe; Farhat, Mohamed

    2017-09-01

    Presented here are observations that demonstrate how the deformation of millimetric cavitation bubbles by a uniform pressure gradient quenches single-collapse luminescence. Our innovative measurement system captures a broad luminescence spectrum (wavelength range, 300-900 nm) from the individual collapses of laser-induced bubbles in water. By varying the bubble size, driving pressure, and perceived gravity level aboard parabolic flights, we probed the limit from aspherical to highly spherical bubble collapses. Luminescence was detected for bubbles of maximum radii within the previously uncovered range, R0=1.5 -6 mm, for laser-induced bubbles. The relative luminescence energy was found to rapidly decrease as a function of the bubble asymmetry quantified by the anisotropy parameter ζ , which is the dimensionless equivalent of the Kelvin impulse. As established previously, ζ also dictates the characteristic parameters of bubble-driven microjets. The threshold of ζ beyond which no luminescence is observed in our experiment closely coincides with the threshold where the microjets visibly pierce the bubble and drive a vapor jet during the rebound. The individual fitted blackbody temperatures range between Tlum=7000 and Tlum=11 500 K but do not show any clear trend as a function of ζ . Time-resolved measurements using a high-speed photodetector disclose multiple luminescence events at each bubble collapse. The averaged full width at half-maximum of the pulse is found to scale with R0 and to range between 10 and 20 ns.

  5. Modeling the dynamics of single-bubble sonoluminescence

    International Nuclear Information System (INIS)

    Vignoli, Lucas L; De Barros, Ana L F; Thomé, Roberto C A; Nogueira, A L M A; Paschoal, Ricardo C; Rodrigues, Hilário

    2013-01-01

    Sonoluminescence (SL) is the phenomenon in which acoustic energy is (partially) transformed into light. It may occur by means of one bubble or many bubbles of gas inside a liquid medium, giving rise to the terms single-bubble and multi-bubble sonoluminescence (SBSL and MBSL). In recent years some models have been proposed to explain this phenomenon, but there is still no complete theory for the light-emission mechanism (especially in the case of SBSL). In this paper, we do not address this more complicated specific issue, but only present a simple model describing the dynamical behavior of the sonoluminescent bubble in the SBSL case. Using simple numerical techniques within the Matlab software package, we discuss solutions that consider various possibilities for some of the parameters involved: liquid compressibility, surface tension, viscosity and type of gas. The model may be used for an introductory study of SL on undergraduate or graduate physics courses, and as a clarifying example of a physical system exhibiting large nonlinearity. (paper)

  6. MR findings of cerebral venous sinus thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Myung Kwan; Chang, Kee Hyun; Han, Moon Hee; Choi, Choong Gom [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1994-10-15

    To describe MR findings of cerebral venous sinus thrombosis. We reviewed 11 MR images of six patients with cerebral venous sinus thrombosis. The MR images were retrospectively analyzed in terms of location and signal intensity of the thrombi, parenchymal lesions such as hemorrhage and edema, and changes in follow up study obtained in 4 patients. The thrombus in venous sinus was visualized on MRI in all six patients. The most frequently involved sites were superior sagittal sinus(n=4) and left transverse sinus(n=4). Signal intensity of the thrombus was isointense or hyperintense on both T1- and T2-weighted images with loss of normal signal void of the sinus on all sequences in all patients. Parenchymal lesion was patients in five of six cases, manifested as local hemorrhage in three and edema in three cases(one case overlapped). Local edema seen in three patients was completely resolved on follow up study of seven to 29 days intervals. It is concluded that iso- or high signal intensity with loss of signal void in venous sinus is virtually diagnostic of venous sinus thrombosis. If there are local parenchymal lesions such as hemorrhage and/or edema of unknown causes, cerebral venous sinus thrombosis should be included in differential diagnosis.

  7. Bubble nucleation in an explosive micro-bubble actuator

    NARCIS (Netherlands)

    van den Broek, D.M.; Elwenspoek, Michael Curt

    2008-01-01

    Explosive evaporation occurs when a thin layer of liquid reaches a temperature close to the critical temperature in a very short time. At these temperatures spontaneous nucleation takes place. The nucleated bubbles instantly coalesce forming a vapour film followed by rapid growth due to the pressure

  8. History of venous leg ulcers.

    Science.gov (United States)

    Gianfaldoni, S; Wollina, U; Lotti, J; Gianfaldoni, R; Lotti, T; Fioranelli, M; Roccia, M G

    To retrieve the history of venous ulcers and of skin lesions in general, we must go back to the appearance of human beings on earth. It is interesting to note that cutaneous injuries evolved parallel to human society. An essential first step in the pathogenesis of ulcers was represented by the transition of the quadruped man to Homo Erectus. This condition was characterized by a greater gravitational pressure on the lower limbs, with consequences on the peripheral venous system. Furthermore, human evolution was characterized by an increased risk of traumatic injuries, secondary to his natural need to create fire and hunt (e.g. stones, iron, fire, animal fighting). Humans then began to fight one another until they came to real wars, with increased frequency of wounds and infectious complications. The situation degraded with the introduction of horse riding, introduced by the Scites, who first tamed animals in the 7th century BC. This condition exhibited iliac veins at compression phenomena, favouring the venous stasis. With time, man continued to evolve until the modern age, which is characterized by increased risk factors for venous wounds such as poor physical activity and dietary errors (1, 2).

  9. Multiple bubbles in a Hele-Shaw cell

    International Nuclear Information System (INIS)

    Vasconcelos, G.L.

    1994-01-01

    A new class of exact solutions is reported for an infinite stream of identical groups of bubbles moving with a constant velocity U in a Hele-Shaw cell when surface tension is neglected. It is suggested that the existence of these solutions might explain some of the complex behavior observed in recent experiments on rising bubbles in a Hele-Shaw cell. Solutions for a finite number of bubbles in a channel are also obtained. In this case, it is shown that solutions with an arbitrary bubble velocity U>V, where V is the fluid velocity at infinity, can in general be obtained from a simple transformation of the solutions for U=2V

  10. Filtering microfluidic bubble trains at a symmetric junction.

    Science.gov (United States)

    Parthiban, Pravien; Khan, Saif A

    2012-02-07

    We report how a nominally symmetric microfluidic junction can be used to sort all bubbles of an incoming train exclusively into one of its arms. The existence of this "filter" regime is unexpected, given that the junction is symmetric. We analyze this behavior by quantifying how bubbles modulate the hydrodynamic resistance in microchannels and show how speeding up a bubble train whilst preserving its spatial periodicity can lead to filtering at a nominally symmetric junction. We further show how such an asymmetric traffic of bubble trains can be triggered in symmetric geometries by identifying conditions wherein the resistance to flow decreases with an increase in the number of bubbles in the microchannel and derive an exact criterion to predict the same.

  11. Association between right-to-left shunts and brain lesions in sport divers.

    Science.gov (United States)

    Gerriets, Tibo; Tetzlaff, Kay; Hutzelmann, Alfred; Liceni, Thomas; Kopiske, Gerrit; Struck, Niklas; Reuter, Michael; Kaps, Manfred

    2003-10-01

    Recent studies suggest that healthy sport divers may develop clinically silent brain damage, based on the association between a finding of multiple brain lesions on MRI and the presence of right-to-left shunt, a pathway for venous gas bubbles to enter the arterial system. We performed echocontrast transcranial Doppler sonography in 42 sport divers to determine the presence of a right-to-left shunt. Cranial MRI was carried out using a 1.5 T magnet. A lesion was counted if it was hyperintense on both T2-weighted and T2-weighted fluid attenuated inversion recovery sequences. To test the hypothesis that the occurrence of postdive arterial gas emboli is related to brain lesions on MRI, we measured postdive intravascular bubbles in a subset of 15 divers 30 min after open water scuba dives. Echocontrast transcranial Doppler sonography revealed a right-to-left shunt in 16 of the divers (38%). Only one hyperintensive lesion of the central white matter was found and that was in a diver with no evidence of a right-to-left shunt. Postdive arterial gas emboli were detected in 3 out of 15 divers; they had a right-to-left shunt, but no pathologic findings on cranial magnetic resonance imaging. Our data support the theory that right-to-left shunts can serve as a pathway for venous gas bubbles into the arterial circulation. However, we could not confirm an association between brain lesions and the presence of a right-to-left shunt in sport divers.

  12. Numerical simulation of single bubble dynamics under acoustic travelling waves.

    Science.gov (United States)

    Ma, Xiaojian; Huang, Biao; Li, Yikai; Chang, Qing; Qiu, Sicong; Su, Zheng; Fu, Xiaoying; Wang, Guoyu

    2018-04-01

    The objective of this paper is to apply CLSVOF method to investigate the single bubble dynamics in acoustic travelling waves. The Naiver-Stokes equation considering the acoustic radiation force is proposed and validated to capture the bubble behaviors. And the CLSVOF method, which can capture the continuous geometric properties and satisfies mass conservation, is applied in present work. Firstly, the regime map, depending on the dimensionless acoustic pressure amplitude and acoustic wave number, is constructed to present different bubble behaviors. Then, the time evolution of the bubble oscillation is investigated and analyzed. Finally, the effect of the direction and the damping coefficient of acoustic wave propagation on the bubble behavior are also considered. The numerical results show that the bubble presents distinct oscillation types in acoustic travelling waves, namely, volume oscillation, shape oscillation, and splitting oscillation. For the splitting oscillation, the formation of jet, splitting of bubble, and the rebound of sub-bubbles may lead to substantial increase in pressure fluctuations on the boundary. For the shape oscillation, the nodes and antinodes of the acoustic pressure wave contribute to the formation of the "cross shape" of the bubble. It should be noted that the direction of the bubble translation and bubble jet are always towards the direction of wave propagation. In addition, the damping coefficient causes bubble in shape oscillation to be of asymmetry in shape and inequality in size, and delays the splitting process. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Negative wake behind bubbles in non-newtonian liquids

    DEFF Research Database (Denmark)

    Hassager, Ole

    1979-01-01

    Gas bubbles rising by gravity in non-Newtonian elastic liquids are different to gas bubbles in viscous Newtonian fluids in at least two ways. First, the bubbles in the non-Newtonian liquids often have a peculiar tip at the rear pole, and second, the terminal rise velocity versus volume curve ofte...

  14. Computed tomographic manifestations of abdominal and pelvic venous collaterals

    International Nuclear Information System (INIS)

    Pagani, J.J.; Thomas, J.L.; Bernardino, M.E.

    1982-01-01

    Obstruction of blood flow through the inferior vena cava and portal vein may produce venous collaterals. These include the paravertebral venous system and its communications with the ascending lumbar veins and azygous/hemiazygous system; gonadal, periureteric, and other retroperitoneal veins; abdominal wall veins; hemorrhoidal venous plexus; and the portal venous system. The anatomic location of these vessels is discussed. Computed tomography demonstrates them as round or tubular structures that are isodens when compared with other venous structures following contrast material administration. Techniques of examination and methods of differentiation of these vascular structures from other abnormalities, especially lymphadenopathy, are discussed

  15. Appearance of a double bubble in achalasia cardia: a case report

    Directory of Open Access Journals (Sweden)

    Lakhan Shaheen E

    2008-12-01

    Full Text Available Abstract Introduction Achalasia cardia is characterized by failure of the lower esophageal sphincter to relax in response to swallowing and by an absence of peristalsis in the esophageal body. Absence of a gastric air bubble is a well known radiological finding. Pneumatic balloon dilatation results in reappearance of the gastric bubble. Case presentation We report the case of a 43-year-old Indian man with achalasia cardia whose chest X-ray at the time of presentation showed an air bubble in the gastric region causing a diagnostic quandary. Successful dilatation of the lower esophageal sphincter resulted in the appearance of another air bubble in the gastric region. Proper analysis showed that the first bubble was actually a colonic air bubble of the splenic flexure and the appearance of the second bubble was the anticipated gastric air bubble. Conclusion In patients presenting with achalasia cardia, a colonic air bubble may be seen in the gastric region causing diagnostic difficulty. In these patients, a gastric air bubble may appear after pneumatic dilatation. At the end of the procedure, there will be two air bubbles ("double bubble": a colonic and a gastric air bubble. To our knowledge, this finding has not been reported in the literature thus far.

  16. Computational approach for a pair of bubble coalescence process

    International Nuclear Information System (INIS)

    Nurul Hasan; Zalinawati binti Zakaria

    2011-01-01

    The coalescence of bubbles has great value in mineral recovery and oil industry. In this paper, two co-axial bubbles rising in a cylinder is modelled to study the coalescence of bubbles for four computational experimental test cases. The Reynolds' (Re) number is chosen in between 8.50 and 10, Bond number, Bo ∼4.25-50, Morton number, M 0.0125-14.7. The viscosity ratio (μ r ) and density ratio (ρ r ) of liquid to bubble are kept constant (100 and 850 respectively). It was found that the Bo number has significant effect on the coalescence process for constant Re, μ r and ρ r . The bubble-bubble distance over time was validated against published experimental data. The results show that VOF approach can be used to model these phenomena accurately. The surface tension was changed to alter the Bo and density of the fluids to alter the Re and M, keeping the μ r and ρ r the same. It was found that for lower Bo, the bubble coalesce is slower and the pocket at the lower part of the leading bubble is less concave (towards downward) which is supported by the experimental data.

  17. Sex-specific aspects of venous thrombosis

    NARCIS (Netherlands)

    Roach, Rachel Elizabeth Jo

    2014-01-01

    Venous thrombosis is a disease that occurs in 1-2 per 1000 people per year. At the time of their first venous thrombosis, approximately 50% of women are exposed to reproductive risk factors (oral contraception, postmenopausal hormone therapy, pregnancy and the puerperium). In this thesis, we showed

  18. Assessment of coagulation function and ultrasound features after reteplase and recombinant streptokinase thrombolysis of lower extremity deep venous thrombosis

    Directory of Open Access Journals (Sweden)

    Wei Xiong

    2016-07-01

    Full Text Available Objective: To assess coagulation function and ultrasound features after reteplase and recombinant streptokinase thrombolysis of lower extremity deep venous thrombosis. Methods: A total of 78 cases of patients with lower extremity deep venous thrombosis who were treated in our hospital were selected as research subjects and divided into observation group 39 cases and control group 39 cases according to different treatment regimens. Control group received recombinant streptokinase thrombolysis, observation group received reteplase thrombolysis, and then the effect of the two thrombolytic ways was evaluated by color Doppler ultrasonography and circulating blood test. Results: Ultrasound showed that complete recanalization rate of thrombus of observation group after treatment was higher than that of control group; plasma PT, APTT and TT values of observation group after thrombolysis were higher than those of control group, FIB, D-D, NO, ET, E-selectin, P-selectin, Hcy, CRP, IL-6, IL-8 and TNF-毩 values were lower than those of control group, and WBC, Nc and Mc cell number were less than those of control group. Conclusion: Reteplase for thrombolysis of lower extremity deep venous thrombosis has more distinguished effect on dissolving thrombus as well as optimizing body’s coagulation, inflammatory system state and other aspects, and is a more ideal thrombolytic drug.

  19. [Venous thrombosis associated with central venous catheter use in patients with cancer].

    Science.gov (United States)

    Iglesias Rey, Leticia; Fernández Pérez, Isaura; Barbagelata López, Cristina; Rivera Gallego, Alberto

    2015-01-01

    The use of central venous catheters for various applications (administration of chemotherapy, blood products and others) in patients with cancer is increasingly frequent. The association between thrombosis and catheter use has been fully established but aspects such as its causes, diagnosis, prophylaxis and treatment have not. We describe a case of thrombosis in a patient with cancer treated with chemotherapy who carried a central venous catheter. We also perform a review of the risk factors, the role of the prophylaxis and the treatment. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  20. Microscopic bubble behaviour in suppression pool during wetwell venting

    Science.gov (United States)

    Zablackaite, G.; Nagasaka, H.; Kikura, H.

    2017-10-01

    During a severe accident PCV failure should be avoided and fission products inside PCV should be confined as much as possible. In order to minimize FPs release, Wetwell venting is conducted by releasing steam-non-condensable gas mixture carrying FPs from the Drywell to Suppression Pool. Steam is condensed by subcooled water in the pool, and most of FPs are retained into water. The removal of FP in the water pool is referred to as “Pool Scrubbing effect”. Hydrodynamic parameters of bubbles have impact on pool scrubbing effect. However, there is only few data available to evaluate quantitatively the bubble behaviour under depressurization and/or thermal stratification conditions. Series of experiments were conducted to evaluate the influence of temperature distribution, non-condensable gas content and pressure in the Wetwell on bubble behaviour. Bubbles were visualized using High Speed Camera and adopting shadowgraphy technique. Applying Particle Tracking Velocimetry, bubble velocity and size distribution were obtained from recorded images. Experimental results show that with increasing suppression pool temperature, bubbles reaching the pool surface decreased in size and traveling velocity became slower. In pressurized wetwell, bubble behaviour was similar to that in the heated up suppression pool case, although bubble parameters were similar to the low temperature case. Higher air content induced water surface movement and bubbles were smaller due to break up.

  1. Establishment of Measurement Techniques for Sliding Bubble on a Horizontal Tube

    International Nuclear Information System (INIS)

    Kim, Yu-Na Kim; Park, Goon-Cherl; Cho, Hyoung-Kyu

    2015-01-01

    The mechanistic wall boiling model includes many parameters relevant with bubble behaviors, such as the bubble departure diameter, bubble lift-off diameter, bubble waiting time, etc. Although there have been a large number of studies investigating bubble behavior, the subjects of observation are almost bubbles on a plane or vertical tube. Since the bubble motion is highly influenced by the directions of gravitational force and the heating surfaces, it is expected that the bubble behavior on a horizontal tube is largely different from those on the other geometry. The heat exchanger of APR+ has horizontal U-tube configuration installed in a water pool, of which diameter is 50mm. The study aims to establish measurement techniques for sliding bubbles on a horizontal tube. The measurement parameters include the diameter, interface area, volume, and velocity of the bubble. Additionally, in order to analyze the force acting on the bubble, liquid velocity measurement method was proposed. This paper presents the procedure of the measurement; the phase separation technique, 3-D reconstruction technique, and velocity measurement techniques. For visualization of the sliding bubble behavior, bubble and liquid velocity measurement methods were established which use two high speed cameras and a continuous LASER for the PTV and PIV. Three steps for the bubble shape and velocity measurement (the phase separation, 3-D reconstruction, and velocity calculation), were successfully set up and verified. A PIV technique which uses two different time duration for two regions where the velocity difference is huge was proposed and tested. Using these methods, various information regarding a sliding bubble can be obtained such as bubble and liquid velocities, shape, volume, surface area etc

  2. Intracranial developmental venous anomaly: is it asymptomatic?

    Science.gov (United States)

    Puente, A Bolívar; de Asís Bravo Rodríguez, F; Bravo Rey, I; Romero, E Roldán

    2018-03-16

    Intracranial developmental venous anomalies are the most common vascular malformation. In the immense majority of cases, these anomalies are asymptomatic and discovered incidentally, and they are considered benign. Very exceptionally, however, they can cause neurological symptoms. In this article, we present three cases of patients with developmental venous anomalies that presented with different symptoms owing to complications derived from altered venous drainage. These anomalies were located in the left insula, right temporal lobe, and cerebellum. The exceptionality of the cases presented as well as of the images associated, which show the mechanism through which the symptoms developed, lies in the low incidence of symptomatic developmental venous anomalies reported in the literature. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Venous sinus stenting for pseudotumour cerebri with venous sinus stenosis

    International Nuclear Information System (INIS)

    Chen Huairui; Bai Rulin; Wu Xiaojun; Qi Xiangqian; Mei Qiyong; Lu Yicheng

    2011-01-01

    Objective: To explore the relation between venous sinus stenosis and pseduotumour cerebri and to discuss the efficacy and strategy of venous sinus stenting for its treatment. Methods: Venous sinus stenting was performed in a total of 9 patients with pseudotumour cerebri accompanied by dural sinus stenosis. The clinical data, including the clinical presentations, intracranial pressure, angiographic findings, pressure of dural sinus,methods of treatment and the therapeutic results, were retrospectively analyzed. Results: Bilateral disc edema was seen in all patients. The pressure gradient in the lateral sinuses was obviously high before stenting (22.67±7.25)mmHg in all patients and a reduction in intra-sinus pressure and pressure gradient was also found (5.78±3.77)mmHg. The symptoms associated with intracranial hypertension were gradually improved or disappeared in two weeks after the placement of the stent in all cases, and the intracranial pressure dropped evidently (12.78±5.97)cm H 2 O. Vision was improved in 7 cases at three months, whereas it remained poor in 2 cases despite normalized intracranial pressure. There was no other permanent procedure-related morbidity. The patients were followed up for 3 months to 5 years, and no recurrence developed. Conclusion: Lateral sinus stenting is an effective method for the treatment of pseudotumour cerebri with dural sinus stenosis. (authors)

  4. Effects of isokinetic calf muscle exercise program on muscle strength and venous function in patients with chronic venous insufficiency.

    Science.gov (United States)

    Ercan, Sabriye; Çetin, Cem; Yavuz, Turhan; Demir, Hilmi M; Atalay, Yurdagül B

    2018-05-01

    Objective The aim of this study was to observe the change of the ankle joint range of motion, the muscle strength values measured with an isokinetic dynamometer, pain scores, quality of life scale, and venous return time in chronic venous insufficiency diagnosed patients by prospective follow-up after 12-week exercise program including isokinetic exercises. Methods The patient group of this study comprised 27 patients (23 female, 4 male) who were diagnosed with chronic venous insufficiency. An exercise program including isokinetic exercise for the calf muscle was given to patients three days per week for 12 weeks. At the end of 12 weeks, five of the patients left the study due to inadequate compliance with the exercise program. As a result, control data of 22 patients were included. Ankle joint range of active motion, isokinetic muscle strength, pain, quality of life, and photoplethysmography measurements were assessed before starting and after the exercise program. Results Evaluating changes of the starting and control data depending on time showed that all isokinetic muscle strength measurement parameters, range of motion, and overall quality of life values of patients improved. Venous return time values have also increased significantly ( p < 0.05). Conclusion In conclusion, increase in muscle strength has been provided with exercise therapy in patients with chronic venous insufficiency. It has been determined that the increase in muscle strength affected the venous pump and this ensured improvement in venous function and range of motion of the ankle. In addition, it has been detected that pain reduced and quality of life improved after the exercise program.

  5. In vivo measurement of circulating leucocyte activation in patients following cardiopulmonary bypass

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Hazel A. E-mail: hazel.jones@imperial.ac.uk; Choudhury, Marina; Harris, David N.F

    2004-10-01

    We have developed a simple technique to measure in vivo activation of circulating leucocytes and assessed it in 6 patients undergoing cardiopulmonary bypass (CPB). Arterial, mixed venous, and jugular bulb blood samples were taken following i.v. [{sup 18}F]FDG, before and after CPB. [{sup 18}F]FDG uptake in leucocytes was measured by phosphor imaging of spun blood-filled capillary tubes. Leucocyte radioactivity was quantified ([(leucocytes-plasma)/plasma radioactivity] and normalised to leucocyte counts. [{sup 18}F]FDG uptake (mean{+-}SEM)) before CPB was undetectable, being -0.014{+-}0.007, -0.011{+-}0.003, -0.012{+-}0.006, -0.010{+-}0.005, whereas increased uptake was demonstrated following CPB, 0.006{+-}0.006, 0.009{+-}0.005, 0.021{+-}0.005, 0.034{+-}0.006, at 20, 40, 60, and 80 min, respectively. There was no significant difference in activation between sampling sites before or after CPB. This method gives a sensitive index of activation of circulating leucocytes in whole blood, enabling investigation of activation of circulating white cells without the influence of sample handling or the requirement for time-consuming cell separation procedures.

  6. Inflammation and peripheral venous disease. The San Diego Population Study.

    Science.gov (United States)

    Cushman, M; Callas, P W; Allison, M A; Criqui, M H

    2014-09-02

    The inflammatory response to healing in venous thrombosis might cause vein damage and post-thrombotic syndrome. Inflammation may also be involved in venous insufficiency apart from deep-vein thrombosis. We studied the association of inflammation markers with venous insufficiency in a general population sample. We characterised 2,404 men and women in a general population cohort for peripheral venous disease and its severity using physical exam, symptom assessment, and venous ultrasound. Inflammation markers, C-reactive protein (CRP), fibrinogen, interleukin 1-beta (IL-1-beta), IL-8, IL-10, intercellular adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1), E-selectin, monocyte chemoattractant-1 (MCP-1) and vascular endothelial cell growth factor (VEGF) were compared in 352 case participants with peripheral venous disease and 352 controls with no venous abnormalities frequency matched to cases by age, sex and race. Associations were also evaluated including a subset of 108 cases of severe venous disease, as previously defined. Odds ratios (95% CI), for peripheral venous disease for biomarkers in the top quartile (adjusting for age, race, sex, body mass index and history of venous thrombosis) were 1.8 (1.1-3.0), 1.6 (1.0-2.5) and 1.5 (0.9-2.3) for CRP, fibrinogen and IL-10, respectively. Associations were larger considering cases of severe venous disease, with odds ratios for these three analytes of 2.6 (1.2-5.9), 3.1 (1.3-7.3) and 2.2 (1.1-4.4), and for IL-8: 2.4 (1.1-5.2). There was no association of IL-1-beta, ICAM-1, VCAM-1, E-selectin, MCP-1 or VEGF with overall cases or severe venous disease. In conclusion, a subset of inflammation markers were associated with increased risk of peripheral venous disease, suggesting potential therapeutic targets for treatment.

  7. Clinicoroentgenological diagnosis of chronic venous ovarian insufficiency

    International Nuclear Information System (INIS)

    Grakova, L.S.; Galkin, E.V.; Naumova, E.B.

    1989-01-01

    The paper is devoted to clinicoroentgenological correlations of venous renogonadal hemodynamics in 168 women of reproductive age (151 women with infertility, habitual abortion, disordered menstrual function and 17 patients without disorders of the reproductive tract). Clinicolaboratory investigation was followed by visceral and parietal flebography for the detection of a pathological venous reflux into the ovarian pampiniform plexus. Clinicoroentgenological semiotics of chronic venous ovarian insufficiency was analyzed. Infertility was shown to be the main clinical manifestation of ovarian varicocele

  8. Exploding and Imaging of Electron Bubbles in Liquid Helium

    Science.gov (United States)

    Yadav, Neha; Vadakkumbatt, Vaisakh; Maris, Humphrey J.; Ghosh, Ambarish

    2017-06-01

    An electron bubble in liquid helium-4 under the saturated vapor pressure becomes unstable and explodes if the pressure becomes more negative than -1.9 bars. In this paper, we use focused ultrasound to explode electron bubbles. We then image at 30,000 frames per second the growth and subsequent collapse of the bubbles. We find that bubbles can grow to as large as 1 mm in diameter within 2 ms after the cavitation event. We examine the relation between the maximum size of the bubble and the lifetime and find good agreement with the experimental results.

  9. An experimental study of particle-bubble interaction and attachment in flotation

    KAUST Repository

    Sanchez Yanez, Aaron

    2017-05-01

    The particle-bubble interaction is found in industrial applications with the purpose of selective separation of materials especially in the mining industry. The separation is achieved with the use of bubbles that collect particles depending on their hydrophobicity. There are few experimental studies involving a single interaction between a bubble and a particle. The purpose of this work is to understand this interaction by the study of a single bubble interacting with a single particle. Experiments were conducted using ultra-pure water, glass particles and air bubbles. Single interactions of particles with bubbles were observed using two high speed cameras. The cameras were placed perpendicular to each other allowing to reconstruct the three-dimensional position of the particle, the bubble and the particle-bubble aggregate. A single size of particle was used varying the size for the bubbles. It was found that the attachment of a particle to a bubble depends on its degree of hydrophobicity and on the relative position of the particle and the bubble before they encounter.

  10. Generation of Submicron Bubbles using Venturi Tube Method

    Science.gov (United States)

    Wiraputra, I. G. P. A. E.; Edikresnha, D.; Munir, M. M.; Khairurrijal

    2016-08-01

    In this experiment, submicron bubbles that have diameters less than 1 millimeter were generated by mixing water and gas by hydrodynamic cavitation method. The water was forced to pass through a venturi tube in which the speed of the water will increase in the narrow section, the throat, of the venturi. When the speed of water increased, the pressure would drop at the throat of the venturi causing the outside air to be absorbed via the gas inlet. The gas was then trapped inside the water producing bubbles. The effects of several physical parameters on the characteristics of the bubbles will be discussed thoroughly in this paper. It was found that larger amount of gas pressure during compression will increase the production rate of bubbles and increase the density of bubble within water.

  11. REVIEW ARTICLE Venous thromboembolism associated with ...

    Indian Academy of Sciences (India)

    Navya

    2017-03-24

    Mar 24, 2017 ... Venous thromboembolism associated with protein S deficiency due to ... 2 Institute of Cardiology, Jagiellonian University Medical College, Kraków, Poland ... It has been long recognized that reduced PS activity is a risk factor for venous ... 1988). Sequencing of PROS1 gene intensified studies of genotype-.

  12. Non-Abelian bubbles in microstate geometries

    Energy Technology Data Exchange (ETDEWEB)

    Ramírez, Pedro F. [Instituto de Física Teórica UAM/CSIC,C/ Nicolás Cabrera, 13-15, C.University Cantoblanco, E-28049 Madrid (Spain); Institut de Physique Théorique, Université Paris Saclay, CEA, CNRS,Orme des Merisiers bâtiment 774, F-91191 Gif-sur-Yvette (France)

    2016-11-24

    We find the first smooth bubbling microstate geometries with non-Abelian fields. The solutions constitute an extension of the BPS three-charge smooth microstates. These consist in general families of regular supersymmetric solutions with non-trivial topology, i.e. bubbles, of N=1, d=5 Super-Einstein-Yang-Mills theory, having the asymptotic charges of a black hole or black ring but with no horizon. The non-Abelian fields make their presence at the very heart of the microstate structure: the physical size of the bubbles is affected by the non-Abelian topological charge they carry, which combines with the Abelian flux threading the bubbles to hold them up. Interestingly the non-Abelian fields carry a set of adjustable continuous parameters that do not alter the asymptotics of the solutions but modify the local geometry. This feature can be used to obtain a classically infinite number of microstate solutions with the asymptotics of a single black hole or black ring.

  13. Creeping motion of long bubbles and drops in capillary tubes

    DEFF Research Database (Denmark)

    Westborg, Henrik; Hassager, Ole

    1989-01-01

    The flow of inviscid bubbles and viscous drops in capillary tubes has been simulated by a Galerkin finite element method with surface tension included at the bubble/liquid interface. The results show good agreement with published experimental results. At low capillary numbers the front and the rear...... of the bubble are nearly spherical. As the capillary number increases the thickness of the wetting film between the tube wall and the bubble increases, and the bubble assumes a more slender shape with a characteristic bump at the rear. Recirculations are found in front and behind the bubble, which disappear...

  14. Interaction of a vortex ring and a bubble

    Science.gov (United States)

    Jha, Narsing K.; Govardhan, Raghuraman N.

    2014-11-01

    Micro-bubble injection in to boundary layers is one possible method for reducing frictional drag of ships. Although this has been studied for some time, the physical mechanisms responsible for drag reduction using microbubbles in turbulent boundary layers is not yet fully understood. Previous studies suggest that bubble-vortical structure interaction seems to be one of the important physical mechanisms for frictional drag reduction using microbubbles. In the present work, we study a simplification of this problem, namely, the interaction of a single vortical structure, in particular a vortex ring, with a single bubble for better understanding of the physics. The vortex ring is generated using a piston-cylinder arrangement and the bubble is generated by connecting a capillary to an air pump. The bubble dynamics is directly visualized using a high speed camera, while the vorticity modification is measured using time resolved PIV. The results show that significant deformations can occur of both the bubble and the vortex ring. Effect of different non-dimensional parameters on the interaction will be presented in the meeting.

  15. Portal-venous gas unrelated to mesenteric ischemia

    International Nuclear Information System (INIS)

    Wiesner, Walter; Mortele, Koenraad J.; Ji, Hoon; Ros, Pablo R.; Glickman, Jonathan N.

    2002-01-01

    The aim of this study was to report on 8 patients with all different non-ischemic etiologies for portal-venous gas and to discuss this rare entity and its potentially misleading CT findings in context with a review of the literature. The CT examinations of eight patients who presented with intrahepatic portal-venous gas, unrelated to bowel ischemia or infarction, were reviewed and compared with their medical records with special emphasis on the pathogenesis and clinical impact of portal-venous gas caused by non-ischemic conditions. The etiologies for portal-venous gas included: abdominal trauma (n=1); large gastric cancer (n=1); prior gastroscopic biopsy (n=1); prior hemicolectomy (n=1); graft-vs-host reaction (n=1); large paracolic abscess (n=1); mesenteric recurrence of ovarian cancer superinfected with clostridium septicum (n=1); and sepsis with Pseudomonas aeruginosa (n=1). The clinical outcome of all patients was determined by their underlying disease and not negatively influenced by the presence of portal-venous gas. Although the presence of portal-venous gas usually raises the suspicion of bowel ischemia and/or intestinal necrosis, this CT finding may be related to a variety of non-ischemic etiologies and pathogeneses as well. The knowledge about these conditions may help to avoid misinterpretation of CT findings, inappropriate clinical uncertainty and unnecessary surgery in certain cases. (orig.)

  16. [Ways to optimize the treatment of patients with discogenic-venous lumbosacral radiculomyeloischemia].

    Science.gov (United States)

    Skoromets, А А; Bubnova, Е V; Endalceva, S М; Kapitonov, D S; Lalayan, Т V; Perfilev, S V; Smolko, D G; Skoromets, А P; Skoromets, Т А; Sukhatskaya, О V; Shmonin, А А

    2015-01-01

    Treatment of patients with neurological manifestations of degenerative-dystrophic lesions of the spine must be integrated and optimized from the perspective of pathogenesis. Antiedematous therapy is an important moment that takes into account the development of localized swelling affected the spinal structures. We studied the efficacy of L-lysine aescinat in the treatment of patients with discogenic-venous lumbosacral radiculomyelopathy. We analyzed the therapeutic efficacy of antitumor therapy with the drug L-lysine aescinat in 40 patients with discogenic-venous lumbosacral radiculomyelopathy in comparison with a control group of 40 patients treated with conventional therapy in a neurological hospital. The age of the patients ranged from 30 to 60 years. In total, there were 36 (45 %) women and 44 (55%) men. Herniated discs were visualized by MRI in all patients, attention was drawn to the condition of radicular veins of the cauda equina. We assessed muscle strength of lumbosacral myotomes, their trophicity and state of segmental-conductor apparatus sensitivity with the quantitative determination of the time of vibration of a tuning fork. The comparison of neurological status dynamics during treatment of inpatients has shown that neurological symptoms reduce more effectively in patients treated with L - lysine aescinat (by 75% during the first 3-5 days) and in a greater number of the patients (77.5% vs 55% in the control group). The authors' experience has shown that venous micro- and macro-circulation disorders play an important role in the pathogenesis of lower lumbar disk hernia. Clinical manifestations of these disorders are segmental and conductive spinal motor disorders in myotomes and sensitivity. Quantitative determination of vibration sensitivity (tuning fork test) is pathognomonic for radiculomyeloischemia. Vein tonics and antiedemics, including L - lysine aescinat as one of the most effective drugs, exert a pathogenetic effect on spondylic and discogenic

  17. Fluid Mechanics of Taylor Bubbles and Slug Flows in Vertical Channels

    International Nuclear Information System (INIS)

    Anglart, Henryk; Podowski, Michael Z.

    2002-01-01

    Fluid mechanics of Taylor bubbles and slug flows is investigated in vertical, circular channels using detailed, three-dimensional computational fluid dynamics simulations. The Volume of Fluid model with the interface-sharpening algorithm, implemented in the commercial CFX4 code, is used to predict the shape and velocity of Taylor bubbles moving along a vertical channel. Several cases are investigated, including both a single Taylor bubble and a train of bubbles rising in water. It is shown that the potential flow solution underpredicts the water film thickness around Taylor bubbles. Furthermore, the computer simulations that are performed reveal the importance of properly modeling the three-dimensional nature of phenomena governing the motion of Taylor bubbles. Based on the present results, a new formula for the evaluation of bubble shape is derived. Both the shape of Taylor bubbles and the bubble rise velocity predicted by the proposed model agree well with experimental observations. Furthermore, the present model shows good promise in predicting the coalescence of Taylor bubbles

  18. Postoperative deep venous thrombosis in Japan. Incidence and prophylaxis

    International Nuclear Information System (INIS)

    Inada, K.; Shirai, N.; Hayashi, M.; Matsumoto, K.; Hirose, M.

    1983-01-01

    The incidence of postoperative deep venous thrombosis was investigated using the iodine-125-fibrinogen method in 256 patients undergoing major surgery. Deep venous thrombosis was found in 49 patients (15.3 percent), and nonfatal pulmonary embolism developed in one of seven patients in whom the thrombus extended to the popliteal vein. The same investigation was performed in 110 patients who wore a graduated compression stocking on one leg, with the other leg serving as a control. Deep venous thrombosis was found in 4 of 110 stockinged legs (3.6 percent) and in 16 of 110 control legs (14.5 percent). The incidence of deep venous thrombosis decreased significantly in patients who wore the stocking. An increase in femoral venous flow velocity was found in the stockinged legs by the Doppler method. The mean velocity of venous return by xenon-133 clearance was significantly greater in the stockinged legs than in the control legs. These findings were considered to support the efficacy of graduated compression stockings for the prevention of deep venous thrombosis

  19. Congenital Retinal Macrovessel and the Association of Retinal Venous Malformations With Venous Malformations of the Brain.

    Science.gov (United States)

    Pichi, Francesco; Freund, K Bailey; Ciardella, Antonio; Morara, Mariachiara; Abboud, Emad B; Ghazi, Nicola; Dackiw, Christine; Choudhry, Netan; Souza, Eduardo Cunha; Cunha, Leonardo Provetti; Arevalo, J Fernando; Liu, T Y Alvin; Wenick, Adam; He, Lingmin; Villarreal, Guadalupe; Neri, Piergiorgio; Sarraf, David

    2018-04-01

    Congenital retinal macrovessel (CRM) is a rarely reported venous malformation of the retina that is associated with venous anomalies of the brain. To study the multimodal imaging findings of a series of eyes with congenital retinal macrovessel and describe the systemic associations. In this cross-sectional multicenter study, medical records were retrospectively reviewed from 7 different retina clinics worldwide over a 10-year period (2007-2017). Patients with CRM, defined as an abnormal, large, macular vessel with a vascular distribution above and below the horizontal raphe, were identified. Data were analyzed from December 2016 to August 2017. Clinical information and multimodal retinal imaging findings were collected and studied. Pertinent systemic information, including brain magnetic resonance imaging findings, was also noted if available. Of the 49 included patients, 32 (65%) were female, and the mean (SD) age at onset was 44.0 (20.9) years. A total of 49 eyes from 49 patients were studied. Macrovessel was unilateral in all patients. Color fundus photography illustrated a large aberrant dilated and tortuous retinal vein in all patients. Early-phase frames of fluorescein angiography further confirmed the venous nature of the macrovessel in 40 of 40 eyes. Optical coherence tomography angiography, available in 17 eyes (35%), displayed microvascular capillary abnormalities around the CRM, which were more evident in the deep capillary plexus. Of the 49 patients with CRM, 39 (80%) did not illustrate any evidence of ophthalmic complications. Ten patients (20%) presented with retinal complications, typically an incidental association with CRM. Twelve patients (24%) were noted to have venous malformations of the brain with associated magnetic resonance imaging. Of these, location of the venous anomaly in the brain was ipsilateral to the CRM in 10 patients (83%) and contralateral in 2 patients (17%), mainly located in the frontal lobe in 9 patients (75%). Our study has

  20. Nano-scale bubble thermonuclear fusion in acoustically cavitated deuterated liquid

    International Nuclear Information System (INIS)

    Robert I Nigmatulin; Richard T Lahey Jr; Rusi Taleyarkhan

    2005-01-01

    Full text of publication follows: It has been experimentally shown (Taleyarkhan, West, Cho, Lahey, Nigmatulin, Block, 2002, 2004) that neutron emission and tritium formation may occur in deuterated acetone (D-acetone C 3 DO 6 ) under acoustic cavitation conditions. Intensity of the fast neutron (2.45 MeV) emission and tritium nucleus production is ∼ 4 x 10 5 s -1 . This suggests ultrahigh compression of matter produced inside bubbles during their collapse. In the paper a systematic theoretical analysis of the vapor bubble growth and subsequent implosion in intense acoustic fields in D-acetone is presented. The goal is to describe and explain the experimental observations of thermonuclear fusion for collapsing cavitation bubble in D-acetone. The dynamics of bubbles formed during maximum rarefaction in the liquid is numerically studied on the basis of the developed models of a single bubble and bubble clusters. It is supposed that during their growth the bubbles coagulate and form a few bigger bubbles, which then collapse under the action of additional pressure pulses produced in the liquid through the intensification of acoustic waves within the cluster. A shock wave is shown to be formed inside the bubble during the latter's rapid contraction. Focusing of this shock wave in the bubble center initiates dissociation and ionization, violent increases in density (10 4 kg m 3 ), pressure (10 10 -10 11 bar) and temperature (2 x 10 8 K), high enough to produce nuclear fusion reactions. The bubble looks like micro-hydrogen bomb. The diameter of the neutron emission zone is about 100 nm. The highest neutron emission is recorded at about 10-20 nm from the bubble center. It is found out that the intensity of bubble implosion and the number of neutron emitted increase with variations in nucleation phase, positive half-wave amplitude, liquid temperature and also with the involvement of coagulation mechanisms within the cluster during the bubble simultaneous growth. The number

  1. Three-Dimensional Reconstruction of a Gas Bubble Trajectory in Liquid

    Directory of Open Access Journals (Sweden)

    Augustyniak Jakub

    2014-01-01

    Full Text Available The identification of the shape of the bubble trajectory is crucial for understanding the mechanism of bubble motion in liquid. In the paper it has been presented the technique of 3D bubble trajectory reconstruction using a single high speed camera and the system of mirrors. In the experiment a glass tank filled with distilled water was used. The nozzle through which the bubbles were generated was placed in the centre of the tank. The movement of the bubbles was recorded with a high speed camera, the Phantom v1610 at a 600 fps. The techniques of image analysis has been applied to determine the coordinates of mass centre of each bubble image. The 3D trajectory of bubble can be obtained by using triangulation methods. In the paper the measurement error of imaging computer tomography has been estimated. The maximum measurement error was equal to ±0,65 [mm]. Trajectories of subsequently departing bubbles were visualized.

  2. Turbulent shear control with oscillatory bubble injection

    International Nuclear Information System (INIS)

    Park, Hyun Jin; Oishi, Yoshihiko; Tasaka, Yuji; Murai, Yuichi; Takeda, Yasushi

    2009-01-01

    It is known that injecting bubbles into shear flow can reduce the frictional drag. This method has advantages in comparison to others in simplicity of installation and also in environment. The amount of drag reduction by bubbles depends on the void fraction provided in the boundary layer. It means, however, that certain power must be consumed to generate bubbles in water, worsening the total power-saving performance. We propose oscillatory bubble injection technique to improve the performance in this study. In order to prove this idea of new type of drag reduction, velocity vector field and shear stress profile in a horizontal channel flow are measured by ultrasonic velocity profiler (UVP) and shear stress transducer, respectively. We measure the gas-liquid interface from the UVP signal, as well. This compound measurement with different principles leads to deeper understanding of bubble-originated drag reduction phenomena, in particular for unsteady process of boundary layer alternation. At these experiments, the results have demonstrated that the intermittency promotes the drag reduction more than normal continuous injection for the same void fraction supplied.

  3. THE INFLUENCE OF GAS-DENSITY AND LIQUID PROPERTIES ON BUBBLE BREAKUP

    NARCIS (Netherlands)

    WILKINSON, PM; VANSCHAYK, A; SPRONKEN, JPM; VANDIERENDONCK, LL

    On the basis of a literature review of bubble breakup experiments, it is demonstrated that both liquid viscosity and surface tension have an influence on bubble stability and, thus, bubble breakup, for small as well as large bubbles. Possible influences of the gas properties on bubble breakup have

  4. Ignition modes of nanosecond discharge with bubbles in distilled water

    International Nuclear Information System (INIS)

    Hamdan, Ahmad; Cha, Min Suk

    2015-01-01

    Here, we present the microscopic physical characteristics of nanosecond discharges with an array of bubbles in distilled water. In particular, applying a single high-voltage pulse, four delayed intensified charge-coupled device cameras successfully visualized four successive images during a single discharge event. We identified three distinctive modes of ignition inside a bubble, depending on the relative location of the bubble with respect to pin-to-hollow needle electrodes when a single bubble was located in an inter-electrode gap of 1 mm: anode-driven ignition, cathode-driven ignition, and co-ignition near both electrodes. Anode- and cathode-driven ignitions evolved into either a complete propagation of the streamer or an incomplete propagation, which were limited in location by proximity to an ignition location, while co-ignitions consistently showed complete propagation. When we increased the gap to 2 mm to accommodate multiple bubbles in the gap, an ignited bubble near the cathode was able to cause the ignition of an upper adjacent bubble. Bubble–bubble interface zones can also be spots of ignition, such that we observed simultaneous co-ignitions in the zones of bubble–bubble interfaces and near electrodes with triple bubbles. We compared the experimental results of discharge propagation with different ignition modes between Ar, He, and N 2 bubbles. In addition, numerical simulations for static electric fields reasonably supported observed ignition behavior such that field intensity was locally enhanced. (paper)

  5. Review—Physicochemical hydrodynamics of gas bubbles in two phase electrochemical systems

    Science.gov (United States)

    Taqieddin, Amir; Nazari, Roya; Rajic, Ljiljana; Alshawabkeh, Akram

    2018-01-01

    Electrochemical systems suffer from poor management of evolving gas bubbles. Improved understanding of bubbles behavior helps to reduce overpotential, save energy and enhance the mass transfer during chemical reactions. This work investigates and reviews the gas bubbles hydrodynamics, behavior, and management in electrochemical cells. Although the rate of bubble growth over the electrode surface is well understood, there is no reliable prediction of bubbles break-off diameter from the electrode surface because of the complexity of bubbles motion near the electrode surface. Particle Image Velocimetry (PIV) and Laser Doppler Anemometry (LDA) are the most common experimental techniques to measure bubble dynamics. Although the PIV is faster than LDA, both techniques are considered expensive and time-consuming. This encourages adapting Computational Fluid Dynamics (CFD) methods as an alternative to study bubbles behavior. However, further development of CFD methods is required to include coalescence and break-up of bubbles for better understanding and accuracy. The disadvantages of CFD methods can be overcome by using hybrid methods. The behavior of bubbles in electrochemical systems is still a complex challenging topic which requires a better understanding of the gas bubbles hydrodynamics and their interactions with the electrode surface and bulk liquid, as well as between the bubbles itself.

  6. Hepatic venous pressure gradients measured by duplex ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M

    2002-08-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P < 0.0001) and with the Child-Pugh score (r = 0.63, P < 0.0001). An acceleration index cut-off value of 1 m.s{sup -2} provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  7. Effects of mixing methods on phase distribution in vertical bubble flow

    International Nuclear Information System (INIS)

    Monji, Hideaki; Matsui, Goichi; Sugiyama, Takayuki.

    1992-01-01

    The mechanism of the phase distribution formation in a bubble flow is one of the most important problems in the control of two-phase flow systems. The effect of mixing methods on the phase distribution was experimentally investigated by using upward nitrogen gas-water bubble flow under the condition of fixed flow rates. The experimental results show that the diameter of the gas injection hole influences the phase distribution through the bubble size. The location of the injection hole and the direction of injection do not influence the phase distribution of fully developed bubble flow. The transitive equivalent bubble size from the coring bubble flow to the sliding bubble flow corresponds to the bubble shape transition. The analytical results show that the phase distribution may be predictable if the phase profile is judged from the bubble size. (author)

  8. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System

    NARCIS (Netherlands)

    Kropff, Jort; van Steen, Sigrid C.; deGraaff, Peter; Chan, Man W.; van Amstel, Rombout B. E.; DeVries, J. Hans

    2017-01-01

    Background: Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. Methods: We evaluated 21 individuals with type 1 diabetes

  9. Cardiorespiratory Interactions in Paediatrics: 'It's (almost always) the circulation stupid!'

    Science.gov (United States)

    Rigby, M L; Rosenthal, M

    2017-03-01

    The interaction of the heart and lungs is probably the most important aspect of life and survival. Fortunately, it is not difficult to understand the fundamentals. The purpose of the lungs and their ventilation is to present oxygen to the circulation via the alveoli and to receive carbon dioxide from the circulation and then expel it. The relations of the heart and lungs and the matching of blood flow to the various organs with ventilation and lung perfusion may be disrupted by a variety of congenital or acquired heart malformations. They include those giving rise to an increased or reduced pulmonary blood flow, elevated pulmonary venous pressure or external physical pressure on the airways or lung parenchyma. Respiratory disorders which compromise cardiac function include states with reduced alveolar ventilation, those with a barrier to ventilation or perfusion, ventilation/perfusion mismatch and pulmonary vascular disease. There is also a fascinating group in which congenital disorders of the heart and lung co-exist to produce very particular modes of abnormal cardiopulmonary interaction. Copyright © 2016. Published by Elsevier Ltd.

  10. Nucleation path of helium bubbles in metals during irradiation

    International Nuclear Information System (INIS)

    Morishita, Kazunori

    2008-01-01

    Thermodynamical formalization is made for description of the nucleation and growth of helium bubbles in metals during irradiation. The proposed formalization is available or evaluating both microstructural changes in fusion first wall materials where helium is produced by (n, α) nuclear transmutation reactions, and those in fusion divertor materials where helium particles with low energy are directly implanted. Calculated nucleation barrier is significantly reduced by the presence of helium, showing that a helium bubble with an appropriate number of helium atoms depending on bubble size can nucleate without any large nucleation barriers, even at a condition where an empty void has very large nucleation barrier without helium. With the proposed thermodynamical formalization, the nucleation and growth process of helium bubbles in iron during irradiation is simulated by the kinetic Monte-Carlo (KMC) technique. It shows the nucleation path of a helium bubble on the (N He , N V ) space as functions of temperatures and the concentration of helium in the matrix, where N He and N V are the number of helium atoms and vacancies in the helium bubble, respectively. Bubble growth rates depend on the nucleation path and suggest that two different mechanisms operate for bubble growth: one is controlled by vacancy diffusion and the other is controlled by interstitial helium diffusion. (author)

  11. Stability of a Bubble Expanding and Translating Through an Inviscid ...

    Indian Academy of Sciences (India)

    A bubble expands adiabatically and translates in an incompressible and inviscid liquid. We investigate the number of equilibrium points of the bubble and the nature of stability of the bubble at these points. We find that there is only one equilibrium point and the bubble is stable there.

  12. Visualization study of film drops produced by bubble bursting

    International Nuclear Information System (INIS)

    Ma Chao; Bo Hanliang

    2012-01-01

    The phenomenon that bubble bursting results in drops production is common in the steam generator of the nuclear power plant, and the fine drops generated by this way is one of the most important source of the drop entrainment in the vapor stream. The visualization experiment about the film drops produced by the bursting bubbles at a free water surface was studied using a high-speed video camera. The results show that the bubble cap breaks up in a single point, within the limits of bubble size in the experiment at present. The whole process can be distinguished into four successive stages: A primary inertial drainage, the bubble cap puncture at the foot or on the top, the film rolls-up and the liquid ring appearing with the hole expanding, and fine film drops emission under the effect of destabilization of a Rayleigh-Taylor type. The expression about the bubble radius and the film drops number is obtain by fitting the experiment data at the bubble radius range from 3-25 mm. The result trend agrees well with the previous work. (authors)

  13. Dynamic Bubble Surface Tension Measurements in Northwest Atlantic Seawater

    Science.gov (United States)

    Kieber, D. J.; Long, M. S.; Keene, W. C.; Kinsey, J. D.; Frossard, A. A.; Beaupre, S. R.; Duplessis, P.; Maben, J. R.; Lu, X.; Chang, R.; Zhu, Y.; Bisgrove, J.

    2017-12-01

    Numerous reports suggest that most organic matter (OM) associated with newly formed primary marine aerosol (PMA) originates from the sea-surface microlayer. However, surface-active OM rapidly adsorbs onto bubble surfaces in the water column and is ejected into the atmosphere when bubbles burst at the air-water interface. Here we present dynamic surface tension measurements of bubbles produced in near surface seawater from biologically productive and oligotrophic sites and in deep seawater collected from 2500 m in the northwest Atlantic. In all cases, the surface tension of bubble surfaces decreased within seconds after the bubbles were exposed to seawater. These observations demonstrate that bubble surfaces are rapidly saturated by surfactant material scavenged from seawater. Spatial and diel variability in bubble surface evolution indicate corresponding variability in surfactant concentrations and/or composition. Our results reveal that surface-active OM is found throughout the water column, and that at least some surfactants are not of recent biological origin. Our results also support the hypothesis that the surface microlayer is a minor to negligible source of OM associated with freshly produced PMA.

  14. Bubble behaviour and mean diameter in subcooled flow boiling

    Energy Technology Data Exchange (ETDEWEB)

    Zeitoun, O.; Shoukri, M. [McMaster Univ., Hamilton, Ontario (Canada)

    1995-09-01

    Bubble behaviour and mean bubble diameter in subcooled upward flow boiling in a vertical annular channel were investigated under low pressure and mass flux conditions. A high speed video system was used to visualize the subcooled flow boiling phenomenon. The high speed photographic results indicated that, contrary to the common understanding, bubbles tend to detach from the heating surface upstream of the net vapour generation point. Digital image processing technique was used to measure the mean bubble diameter along the subcooled flow boiling region. Data on the axial area-averaged void fraction distributions were also obtained using a single beam gamma densitometer. Effects of the liquid subcooling, applied heat flux and mass flux on the mean bubble size were investigated. A correlation for the mean bubble diameter as a function of the local subcooling, heat flux and mass flux was obtained.

  15. Diagnostics of defeats of venous collectors of brain

    International Nuclear Information System (INIS)

    Timofeeva, T.V.; Polunina, I.S.; Shcherbakova, E.Ya.; Kuldakova, S.V.

    1997-01-01

    Comparative data of transcranial ultrasonic dopplerography (170 patients) and radionuclidous antroscintigraphy (124), received during diagnostics of defects of venous collectors of brain are analyzed. Five variants of defeats of venous collectors (cross, sigmoid, internal of jugular of jugular vein), but also unpaired sine (direct, confluent) are described. Received results permit to reveal interrelation of infringements of venous outflow and increase of intracranial pressure

  16. Congenital absence of infrarenal IVC and iliac venous system : Unusual collateral Pathways

    International Nuclear Information System (INIS)

    Lee, Jin Joo; Lee, Byung Hee; Kim, Kie Hwan; Do, Young Soo; Chin, Soo Yil

    1994-01-01

    We present a case with congenital absence of the infrarenal portion of inferior vena cava and iliac venous system, showing unusual venous collaterals including the left ovarian venous collateral via parametrial venous complex, and a mesenteric-periureteric venous connection. The venous collateral pathways were demonstrated by computed tomography and venography

  17. Dependence of bubble behavior in subcooled boiling on surface wettability

    International Nuclear Information System (INIS)

    Harada, Takahiro; Nagakura, Hiroshi; Okawa, Tomio

    2010-01-01

    This paper presents the results of visualization experiments that were carried out to investigate the dynamics of vapor bubbles generated in water pool boiling. In the experiments, vapor bubbles were generated on a vertical circular surface of a copper block containing nine cartridge heaters, and the contact angle of the heated surface was used as a main experimental parameter. The experiments were performed under subcooled as well as nearly saturated conditions. To enable clear observation of individual bubbles with a high speed camera, the heat flux was kept low enough to eliminate significant overlapping of bubbles. When the contact angle was small, the bubbles were lifted-off the vertical heated surface within a short period of time after the nucleation. On the other hand, when the contact angle was large, they slid up the vertical surface for a long distance. When bubbles were lifted-off the heated surface in subcooled liquid, bubble life-time was significantly shortened since bubbles collapsed rapidly due to condensation. It was shown that this distinct difference in bubble dynamics could be attributed to the effects of surface tension force.

  18. Observation of high-temperature bubbles in an ECR plasma

    Science.gov (United States)

    Terasaka, K.; Yoshimura, S.; Tanaka, M. Y.

    2018-05-01

    Creation and annihilation of high-temperature bubbles have been observed in an electron cyclotron resonance plasma. The electron temperature in the bubble core is three times higher than that in the ambient region, and the size perpendicular to the magnetic field is much smaller than the plasma diameter. Formation of a bubble accompanies large negative spikes in the floating potential of a Langmuir probe, and the spatiotemporal behavior of the bubble has been visualized with a high-impedance wire grid detector. It is found that the bubble is in a prolate spheroidal shape with the axis along the magnetic field and occurs randomly in time and independently in space.

  19. Champagne experiences various rhythmical bubbling regimes in a flute.

    Science.gov (United States)

    Liger-Belair, Gérard; Tufaile, Alberto; Jeandet, Philippe; Sartorelli, José-Carlos

    2006-09-20

    Bubble trains are seen rising gracefully from a few points on the glass wall (called nucleation sites) whenever champagne is poured into a glass. As time passes during the gas-discharging process, the careful observation of some given bubble columns reveals that the interbubble distance may change suddenly, thus revealing different rhythmical bubbling regimes. Here, it is reported that the transitions between the different bubbling regimes of some nucleation sites during gas discharging is a process which may be ruled by a strong interaction between tiny gas pockets trapped inside the nucleation site and/or also by an interaction between the tiny bubbles just blown from the nucleation site.

  20. Dechanneling of particles by gas bubbles

    International Nuclear Information System (INIS)

    Ronikier-Polonsky, Danuta.

    1976-01-01

    The dechanneling probability P of a particle hitting a gas bubble in a solid is evaluated theoretically. This probability is found to depend neither on the energy of the particle, nor on the radius of the bubble. A simple expression of P is given in the case of a harmonic channeling potential. Then an experiment is described concerning α particles channeled along (111) planes in aluminium containing helium bubbles. In this particular case, the measured probabilitity (P=0.27+-0.09) is in good agreement with the corresponding theoretical values (0.34 for a harmonic potential and 0.24 for a more realistic potential) [fr

  1. Experimental observation of exploding electron bubbles

    International Nuclear Information System (INIS)

    Classen, J.; Su, C.K.; Hall, S.C.; Pettersen, M.S.; Maris, H.J.

    1996-01-01

    Since free electrons form small voids in liquid helium they are expected to be preferred sites for nucleating macroscopic bubbles when the liquid is exposed to sufficiently large negative pressures. We have performed a series of cavitation experiments using focussed ultrasound where free electrons were introduced into the liquid by a radioactive source. The electron bubbles are found to explode at negative pressures significantly lower than those required for homogeneous nucleation. We present measurements of the thresholds for cavitation at electrons in the temperature range 1 - 4.5 K. Reasonable agreement with a simple model for the stability limit of the electron bubble is obtained. (author)

  2. Partial coalescence from bubbles to drops

    KAUST Repository

    Zhang, F. H.

    2015-10-07

    The coalescence of drops is a fundamental process in the coarsening of emulsions. However, counter-intuitively, this coalescence process can produce a satellite, approximately half the size of the original drop, which is detrimental to the overall coarsening. This also occurs during the coalescence of bubbles, while the resulting satellite is much smaller, approximately 10 %. To understand this difference, we have conducted a set of coalescence experiments using xenon bubbles inside a pressure chamber, where we can continuously raise the pressure from 1 up to 85 atm and thereby vary the density ratio between the inner and outer fluid, from 0.005 up to unity. Using high-speed video imaging, we observe a continuous increase in satellite size as the inner density is varied from the bubble to emulsion-droplet conditions, with the most rapid changes occurring as the bubble density grows up to 15 % of that of the surrounding liquid. We propose a model that successfully relates the satellite size to the capillary wave mode responsible for its pinch-off and the overall deformations from the drainage. The wavelength of the primary wave changes during its travel to the apex, with the instantaneous speed adjusting to the local wavelength. By estimating the travel time of this wave mode on the bubble surface, we also show that the model is consistent with the experiments. This wavenumber is determined by both the global drainage as well as the interface shapes during the rapid coalescence in the neck connecting the two drops or bubbles. The rate of drainage is shown to scale with the density of the inner fluid. Empirically, we find that the pinch-off occurs when 60 % of the bubble fluid has drained from it. Numerical simulations using the volume-of-fluid method with dynamic adaptive grid refinement can reproduce these dynamics, as well as show the associated vortical structure and stirring of the coalescing fluid masses. Enhanced stirring is observed for cases with second

  3. Predictors of Venous Thromboembolic Events Associated with Central Venous Port Insertion in Cancer Patients

    Directory of Open Access Journals (Sweden)

    Christine Hohl Moinat

    2014-01-01

    Full Text Available Insertion of central venous port (CVP catheter in the cancer population is associated with increased incidence of venous thromboembolic events (VTE. However, trials have shown limited benefit of antithrombotic treatment to prevent catheter-related venous thrombosis. This prospective observational cohort study was designed to assess the incidence of VTE closely related to CVP implantation in patients with cancer and undergoing chemotherapy, and to identify a high risk subgroup of patients. Between February 2006 and December 2011, 1097 consecutive cancer patients with first CVP implantation were included. Catheter-related VTE were defined as deep venous thrombosis in the arm, with or without pulmonary embolism (PE, or isolated PE. The incidence of CVP-associated VTE was 5.9% (IC95 4.4–7.3% at 3 months, and 11.3% (IC95 9.4–13.2% at 12 months. The incidence of any VTE was 7.6% (IC95 6.0–9.3% at 3 months, and 15.3% (IC95 13.1–17.6% at 12 months. High Khorana risk score and lung cancer were significant predictors of 3 month VTE. In conclusion, this large cohort study of patients with first CVP catheter implantation confirms the high incidence of VTE associated with the CVP implantation and allow identifying high risk patients who may benefit from thromboprophylaxis.

  4. Bubble clustering in a glass of stout beer

    Science.gov (United States)

    Iwatsubo, Fumiya; Watamura, Tomoaki; Sugiyama, Kazuyasu

    2017-11-01

    To clarify why the texture in stout beer poured into a pint glass descends, we investigated local time development of the void fraction and velocity of bubbles. The propagation of the number density distribution, i.e. the texture, appearing near the inclined wall is observed. We visualized individual advective bubbles near the inclined wall by microscope and measured the local void fraction using brightness of images while the velocity of bubbles by means of Particle Tracking Velocimetry. As the result of measurements, we found the local void fraction and the bubbles advection velocity increase and decrease repeatedly with a time delay. We conclude the texture pattern is composed of fluid blobs which contain less bubbles; extruding and suction flows respectively toward and from the interior of the container form respectively in front and back of the blobs.

  5. Mechanochemical endovenous ablation and new frontiers in venous intervention

    NARCIS (Netherlands)

    Boersma, D

    2017-01-01

    Venous insufficiency of the lower extremities is a common condition and related to various symptoms, including venous ulcers. The effect of venous insufficiency on patients’ health-related quality of life is substantial and comparable with other chronic diseases such as arthritis, diabetes, and

  6. Microlayer Topology And Bubble Growth In Nucleate Boiling

    Science.gov (United States)

    Jawurek, H. H.; Macgregor, H. G.; Bodenheimer, J. S.

    1987-09-01

    During nucleate boiling thin liquid films (nicrolayers) form beneath the base of bubbles and evaporate into the bubble interiors. A technique is presented which permits the simultaneous determination of microlayer topology and the contribution of microlayer evaporation to bubble growth. Isolated-bubble boiling takes place on an electrically heated, transparent tin-oxide coating deposited on a glass plate, the latter forming the floor of a vessel. With coherent Claser) illumination from beneath, the microlayers reflect fringe patterns similar to Newton's rings. Owing to the rapid evaporation of the layers (the process is completed within milliseconds) the fringes are in rapid motion and are recorded by eine photography at some 4 000 frames per second and exposure times of 50 μs. The resulting interferograms provide details of microlayer shape and thickness versus time, and thus evaporation rate. Simultaneously, and on the same film, bubble profiles (and thus volumes) are obtained under white light illumination. The two bubble images are manipulated by mirrors and lenses so as to appear side by side on the same frame of film, the fringes magnified and the profiles reduced. Sample results for methanol boiling at a pressure of 58.5 kPa and with the liquid bulk at saturation temperature, are presented. Under such conditions microlayer evaporation accounts for 37 per cent of the total bubble volume at detachment.

  7. Pregnancy-related venous thromboembolism and risk of occult cancer

    DEFF Research Database (Denmark)

    Tarp Hansen, Anette; Veres, Katalin; Horváth-Puhó, Erzsébet

    2017-01-01

    The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected.An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk.......The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected.An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk....

  8. Pregnancy-related venous thromboembolism and risk of occult cancer

    DEFF Research Database (Denmark)

    Hansen, Anette Tarp; Veres, Katalin; Horváth-Puhó, Erzsébet

    2017-01-01

    The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected. An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk.......The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected. An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk....

  9. Single-bubble dynamics in pool boiling of one-component fluids

    KAUST Repository

    Xu, Xinpeng; Qian, Tiezheng

    2014-01-01

    We numerically investigate the pool boiling of one-component fluids with a focus on the effects of surface wettability on the single-bubble dynamics. We employed the dynamic van der Waals theory [Phys. Rev. E 75, 036304 (2007)], a diffuse-interface model for liquid-vapor flows involving liquid-vapor transition in nonuniform temperature fields. We first perform simulations for bubbles on homogeneous surfaces. We find that an increase in either the contact angle or the surface superheating can enhance the bubble spreading over the heating surface and increase the bubble departure diameter as well and therefore facilitate the transition into film boiling. We then examine the dynamics of bubbles on patterned surfaces, which incorporate the advantages of both hydrophobic and hydrophilic surfaces. The central hydrophobic region increases the thermodynamic probability of bubble nucleation while the surrounding hydrophilic region hinders the continuous bubble spreading by pinning the contact line at the hydrophobic-hydrophilic intersection. This leads to a small bubble departure diameter and therefore prevents the transition from nucleate boiling into film boiling. With the bubble nucleation probability increased and the bubble departure facilitated, the efficiency of heat transfer on such patterned surfaces is highly enhanced, as observed experimentally [Int. J. Heat Mass Transfer 57, 733 (2013)]. In addition, the stick-slip motion of contact line on patterned surfaces is demonstrated in one-component fluids, with the effect weakened by surface superheating.

  10. Single-bubble dynamics in pool boiling of one-component fluids

    KAUST Repository

    Xu, Xinpeng

    2014-06-04

    We numerically investigate the pool boiling of one-component fluids with a focus on the effects of surface wettability on the single-bubble dynamics. We employed the dynamic van der Waals theory [Phys. Rev. E 75, 036304 (2007)], a diffuse-interface model for liquid-vapor flows involving liquid-vapor transition in nonuniform temperature fields. We first perform simulations for bubbles on homogeneous surfaces. We find that an increase in either the contact angle or the surface superheating can enhance the bubble spreading over the heating surface and increase the bubble departure diameter as well and therefore facilitate the transition into film boiling. We then examine the dynamics of bubbles on patterned surfaces, which incorporate the advantages of both hydrophobic and hydrophilic surfaces. The central hydrophobic region increases the thermodynamic probability of bubble nucleation while the surrounding hydrophilic region hinders the continuous bubble spreading by pinning the contact line at the hydrophobic-hydrophilic intersection. This leads to a small bubble departure diameter and therefore prevents the transition from nucleate boiling into film boiling. With the bubble nucleation probability increased and the bubble departure facilitated, the efficiency of heat transfer on such patterned surfaces is highly enhanced, as observed experimentally [Int. J. Heat Mass Transfer 57, 733 (2013)]. In addition, the stick-slip motion of contact line on patterned surfaces is demonstrated in one-component fluids, with the effect weakened by surface superheating.

  11. Drop impact entrapment of bubble rings

    KAUST Repository

    Thoraval, M.-J.

    2013-04-29

    We use ultra-high-speed video imaging to look at the initial contact of a drop impacting on a liquid layer. We observe experimentally the vortex street and the bubble-ring entrapments predicted numerically, for high impact velocities, by Thoraval et al. (Phys. Rev. Lett., vol. 108, 2012, article 264506). These dynamics mainly occur within 50 -s after the first contact, requiring imaging at 1 million f.p.s. For a water drop impacting on a thin layer of water, the entrapment of isolated bubbles starts through azimuthal instability, which forms at low impact velocities, in the neck connecting the drop and pool. For Reynolds number Re above -12 000, up to 10 partial bubble rings have been observed at the base of the ejecta, starting when the contact is -20% of the drop size. More regular bubble rings are observed for a pool of ethanol or methanol. The video imaging shows rotation around some of these air cylinders, which can temporarily delay their breakup into micro-bubbles. The different refractive index in the pool liquid reveals the destabilization of the vortices and the formation of streamwise vortices and intricate vortex tangles. Fine-scale axisymmetry is thereby destroyed. We show also that the shape of the drop has a strong influence on these dynamics. 2013 Cambridge University Press.

  12. An experimental study of particle-bubble interaction and attachment in flotation

    KAUST Repository

    Sanchez Yanez, Aaron

    2017-01-01

    bubbles were observed using two high speed cameras. The cameras were placed perpendicular to each other allowing to reconstruct the three-dimensional position of the particle, the bubble and the particle-bubble aggregate. A single size of particle was used varying the size for the bubbles. It was found that the attachment of a particle to a bubble depends on its degree of hydrophobicity and on the relative position of the particle and the bubble before they encounter.

  13. Bubble collisions and measures of the multiverse

    International Nuclear Information System (INIS)

    Salem, Michael P.

    2012-01-01

    To compute the spectrum of bubble collisions seen by an observer in an eternally-inflating multiverse, one must choose a measure over the diverging spacetime volume, including choosing an ''initial'' hypersurface below which there are no bubble nucleations. Previous calculations focused on the case where the initial hypersurface is pushed arbitrarily deep into the past. Interestingly, the observed spectrum depends on the orientation of the initial hypersurface, however one's ability observe the effect rapidly decreases with the ratio of inflationary Hubble rates inside and outside one's bubble. We investigate whether this conclusion might be avoided under more general circumstances, including placing the observer's bubble near the initial hypersurface. We find that it is not. As a point of reference, a substantial appendix reviews relevant aspects of the measure problem of eternal inflation

  14. The 2008 oil bubble. Causes and consequences

    International Nuclear Information System (INIS)

    Tokic, Damir

    2010-01-01

    We argue that 'the 2008 Oil Bubble' was directly and indirectly created by the Federal Reserve in response to deflationary risks that resurfaced after the housing bubble burst and the resulting credit crisis of 2008. Deflationary risks first appeared after the dot.com bubble burst in 2000 and after the terrorist attacks on September 11, 2001. Manipulation of the US dollar value has been one of the key emergency tools in the Fed's arsenal. During the entire period from 2000 to 2008, the US dollar has been falling, while the price of crude oil has been rising, with the culmination in July 2008. If other global central banks embrace the Fed's anti-deflationary strategies, the consequences could be dire for the global economy, potentially resulting in an ultimate gold bubble. (author)

  15. Central venous catheters: the role of radiology

    International Nuclear Information System (INIS)

    Tan, P.L.; Gibson, M.

    2006-01-01

    The insertion and management of long-term venous catheters have long been the province of anaesthetists, intensive care physicians and surgeons. Radiologists are taking an increasing role in the insertion of central venous catheters (CVCs) because of their familiarity with the imaging equipment and their ability to manipulate catheters and guide-wires. The radiological management of the complications of CVCs has also expanded as a result. This article reviews the role of radiology in central venous access, covering the detection and management of their complications

  16. Experimental Analysis of a Bubble Wake Influenced by a Vortex Street

    Directory of Open Access Journals (Sweden)

    Sophie Rüttinger

    2018-01-01

    Full Text Available Bubble column reactors are ubiquitous in engineering processes. They are used in waste water treatment, as well as in the chemical, pharmaceutical, biological and food industry. Mass transfer and mixing, as well as biochemical or chemical reactions in such reactors are determined by the hydrodynamics of the bubbly flow. The hydrodynamics of bubbly flows is dominated by bubble wake interactions. Despite the fact that bubble wakes have been investigated intensively in the past, there is still a lack of knowledge about how mass transfer from bubbles is influenced by bubble wake interactions in detail. The scientific scope of this work is to answer the question how bubble wakes are influenced by external flow structures like a vortex street behind a cylinder. For this purpose, the flow field in the vicinity of a single bubble is investigated systematically with high spatial and temporal resolution. High-speed Particle Image Velocimetry (PIV measurements are conducted monitoring the flow structure in the equatorial plane of the single bubble. It is shown that the root mean square (RMS velocity profiles downstream the bubble are influenced significantly by the interaction of vortices. In the presence of a vortex street, the deceleration of the fluid behind the bubble is compensated earlier than in the absence of a vortex street. This happens due to momentum transfer by cross-mixing. Both effects indicate that the interaction of vortices enhances the cross-mixing close to the bubble. Time series of instantaneous velocity fields show the formation of an inner shear layer and coupled vortices. In conclusion, this study shows in detail how the bubble wake is influenced by a vortex street and gives deep insights into possible effects on mixing and mass transfer in bubbly flows.

  17. Impurity bubbles in a BEC

    Science.gov (United States)

    Timmermans, Eddy; Blinova, Alina; Boshier, Malcolm

    2013-05-01

    Polarons (particles that interact with the self-consistent deformation of the host medium that contains them) self-localize when strongly coupled. Dilute Bose-Einstein condensates (BECs) doped with neutral distinguishable atoms (impurities) and armed with a Feshbach-tuned impurity-boson interaction provide a unique laboratory to study self-localized polarons. In nature, self-localized polarons come in two flavors that exhibit qualitatively different behavior: In lattice systems, the deformation is slight and the particle is accompanied by a cloud of collective excitations as in the case of the Landau-Pekar polarons of electrons in a dielectric lattice. In natural fluids and gases, the strongly coupled particle radically alters the medium, e.g. by expelling the host medium as in the case of the electron bubbles in superfluid helium. We show that BEC-impurities can self-localize in a bubble, as well as in a Landau-Pekar polaron state. The BEC-impurity system is fully characterized by only two dimensionless coupling constants. In the corresponding phase diagram the bubble and Landau-Pekar polaron limits correspond to large islands separated by a cross-over region. The same BEC-impurity species can be adiabatically Feshbach steered from the Landau-Pekar to the bubble regime. This work was funded by the Los Alamos LDRD program.

  18. Guest investigator program study: Physics of equatorial plasma bubbles

    Science.gov (United States)

    Tsunoda, Roland T.

    1994-01-01

    Plasma bubbles are large-scale (10 to 100 km) depletions in plasma density found in the night-time equatorial ionosphere. Their formation has been found to entail the upward transport of plasma over hundreds of kilometers in altitude, suggesting that bubbles play significant roles in the physics of many of the diverse and unique features found in the low-latitude ionosphere. In the simplest scenario, plasma bubbles appear first as perturbations in the bottomside F layer, which is linearly unstable to the gravitationally driven Rayleigh-Taylor instability. Once initiated, bubbles develop upward through the peak of the F layer into its topside (sometimes to altitudes in excess of 1000 km), a behavior predicted by the nonlinear form of the same instability. While good general agreement has been found between theory and observations, little is known about the detailed physics associated with plasma bubbles. Our research activity centered around two topics: the shape of plasma bubbles and associated electric fields, and the day-to-day variability in the occurrence of plasma bubbles. The first topic was pursued because of a divergence in view regarding the nonlinear physics associated with plasma bubble development. While the development of perturbations in isodensity contours in the bottomside F layer into plasma bubbles is well accepted, some believed bubbles to be cylinder-like closed regions of depleted plasma density that floated upward leaving a turbulent wake behind them (e.g., Woodman and LaHoz, 1976; Ott, 1978; Kelley and Ott, 1978). Our results, summarized in a paper submitted to the Journal of Geophysical Research, consisted of incoherent scatter radar measurements that showed unambiguously that the depleted region is wedgelike and not cylinderlike, and a case study and modeling of SM-D electric field instrument (EFI) measurements that showed that the absence of electric-field perturbations outside the plasma-depleted region is a distinct signature of wedge

  19. Discrete bubble modeling for a micro-structured bubble column

    NARCIS (Netherlands)

    Jain, D.; Lau, Y.M.; Kuipers, J.A.M.; Deen, N.G.

    2013-01-01

    Gas–liquid flows with solid catalyst particles are encountered in many applications in the chemical, petrochemical, pharmaceutical industries, etc. Most commonly, two reactor types are applied for large scale in the industry. They are slurry bubble column and trickle bed reactors. Both of these

  20. Numerical simulation of the dynamic flow behaviour in a bubble column: comparison of the bubble-induced turbulence models in K-epsilon model

    NARCIS (Netherlands)

    Zhang, D.; Deen, N.G.; Kuipers, J.A.M.

    2005-01-01

    Numerical simulations of the gas-liquid bubbly flow in a bubble column were conducted with the commercial CFD package CFX-4.4 to investigate the performance of three models (Pfleger and Becker, 2001; Sato and Sekoguchi, 1975; Troshko and Hassan, 2001) to account for the bubble-induced turbulence in